Sample records for monitoring simultaneous analysis

  1. Thermal Analysis for Monitoring Effects of Shock-Induced Physical, Mechanical, and Chemical Changes in Materials

    DTIC Science & Technology

    2015-01-19

    MS WINDOWS platform, which enables multitasking with simultaneous evaluation and operation 1. REPORT DATE (DD-MM-YYYY) 4. TITLE AND SUBTITLE 13...measurement and analysis software for data acquisition, storage and evaluation with MS WINDOWS platform, which enables multitasking with simultaneous...Proteus measurement and analysis software for data acquisition, storage and evaluation with MS WINDOWS platform, which enables multitasking with

  2. MARVEL: A knowledge-based productivity enhancement tool for real-time multi-mission and multi-subsystem spacecraft operations

    NASA Astrophysics Data System (ADS)

    Schwuttke, Ursula M.; Veregge, John, R.; Angelino, Robert; Childs, Cynthia L.

    1990-10-01

    The Monitor/Analyzer of Real-time Voyager Engineering Link (MARVEL) is described. It is the first automation tool to be used in an online mode for telemetry monitoring and analysis in mission operations. MARVEL combines standard automation techniques with embedded knowledge base systems to simultaneously provide real time monitoring of data from subsystems, near real time analysis of anomaly conditions, and both real time and non-real time user interface functions. MARVEL is currently capable of monitoring the Computer Command Subsystem (CCS), Flight Data Subsystem (FDS), and Attitude and Articulation Control Subsystem (AACS) for both Voyager spacecraft, simultaneously, on a single workstation. The goal of MARVEL is to provide cost savings and productivity enhancement in mission operations and to reduce the need for constant availability of subsystem expertise.

  3. Ambulatory monitoring of activities and motor symptoms in Parkinson's disease.

    PubMed

    Zwartjes, Daphne G M; Heida, Tjitske; van Vugt, Jeroen P P; Geelen, Jan A G; Veltink, Peter H

    2010-11-01

    Ambulatory monitoring of motor symptoms in Parkinsons disease (PD) can improve our therapeutic strategies, especially in patients with motor fluctuations. Previously published monitors usually assess only one or a few basic aspects of the cardinal motor symptoms in a laboratory setting. We developed a novel ambulatory monitoring system that provides a complete motor assessment by simultaneously analyzing current motor activity of the patient (e.g. sitting, walking) and the severity of many aspects related to tremor, bradykinesia, and hypokinesia. The monitor consists of a set of four inertial sensors. Validity of our monitor was established in seven healthy controls and six PD patients treated with deep brain stimulation (DBS) of the subthalamic nucleus. Patients were tested at three different levels of DBS treatment. Subjects were monitored while performing different tasks, including motor tests of the Unified Parkinsons Disease Rating Scale (UPDRS). Output of the monitor was compared to simultaneously recorded videos. The monitor proved very accurate in discriminating between several motor activities. Monitor output correlated well with blinded UPDRS ratings during different DBS levels. The combined analysis of motor activity and symptom severity by our PD monitor brings true ambulatory monitoring of a wide variety of motor symptoms one step closer..

  4. Nondestructive assessment of waveguides using an integrated electromechanical impedance and ultrasonic waves approach

    NASA Astrophysics Data System (ADS)

    Nasrollahi, Amir; Ma, Zhaoyun; Rizzo, Piervincenzo

    2017-04-01

    In this paper we present a structural health monitoring (SHM) paradigm based on the simultaneous use of ultrasounds and electromechanical impedance (EMI) to monitor waveguides. The paradigm uses guided ultrasonic waves (GUWs) in pitch-catch mode and EMI simultaneously. The two methodologies are driven by the same sensing/hardware/software unit. To assess the feasibility of this unified system an aluminum plate was monitored for varying damage location. Damage was simulated by adding small masses to the plate. The results associated with pitch-catch GUW testing mode were used in ultrasonic tomography, and statistical analysis was used to detect the damages using the EMI measurements. The results of GUW and EMI monitoring show that the proposed system is robust and can be developed further to address the challenges associated with the SHM of complex structures.

  5. Simultaneous and independent optical impairments monitoring using singular spectrum analysis of asynchronously sampled signal amplitudes

    NASA Astrophysics Data System (ADS)

    Guesmi, Latifa; Menif, Mourad

    2015-09-01

    Optical performance monitoring (OPM) becomes an inviting topic in high speed optical communication networks. In this paper, a novel technique of OPM based on a new elaborated computation approach of singular spectrum analysis (SSA) for time series prediction is presented. Indeed, various optical impairments among chromatic dispersion (CD), polarization mode dispersion (PMD) and amplified spontaneous emission (ASE) noise are a major factors limiting quality of transmission data in the systems with data rates lager than 40 Gbit/s. This technique proposed an independent and simultaneous multi-impairments monitoring, where we used SSA of time series analysis and forecasting. It has proven their usefulness in the temporal analysis of short and noisy time series in several fields, that it is based on the singular value decomposition (SVD). Also, advanced optical modulation formats (100 Gbit/s non-return-to zero dual-polarization quadrature phase shift keying (NRZ-DP-QPSK) and 160 Gbit/s DP-16 quadrature amplitude modulation (DP-16QAM)) offering high spectral efficiencies have been successfully employed by analyzing their asynchronously sampled amplitude. The simulated results proved that our method is efficient on CD, first-order PMD, Q-factor and OSNR monitoring, which enabled large monitoring ranges, the CD in the range of 170-1700 ps/nm.Km and 170-1110 ps/nm.Km for 100 Gbit/s NRZ-DP-QPSK and 160 Gbit/s DP-16QAM respectively, and also the DGD up to 20 ps is monitored. We could accurately monitor the OSNR in the range of 10-40 dB with monitoring error remains less than 1 dB in the presence of large accumulated CD.

  6. Ultra-performance liquid chromatography tandem mass-spectrometry (uplc-ms/ms) for the rapid, simultaneous analysis of thiamin, riboflavin, flavin adenine dinucleotide, nicotinamide and pyridoxal in human milk

    USDA-ARS?s Scientific Manuscript database

    A novel, rapid and sensitive Ultra Performance Liquid-Chromatography tandem Mass-Spectrometry (UPLC-MS/MS) method for the simultaneous determination of several B-vitamins in human milk was developed. Resolution by retention time or multiple reaction monitoring (MRM) for thiamin, riboflavin, flavin a...

  7. Capillary electrophoresis with laser-induced fluorescence detection: a sensitive method for monitoring extracellular concentrations of amino acids in the periaqueductal grey matter.

    PubMed

    Bergquist, J; Vona, M J; Stiller, C O; O'Connor, W T; Falkenberg, T; Ekman, R

    1996-03-01

    The use of capillary electrophoresis with laser-induced fluorescence detection (CE-LIF) for the analysis of microdialysate samples from the periaqueductal grey matter (PAG) of freely moving rats is described. By employing 3-(4-carboxybenzoyl)-2-quinoline-carboxaldehyde (CBQCA) as a derivatization agent, we simultaneously monitored the concentrations of 8 amino acids (arginine, glutamine, valine, gamma-amino-n-butyric acid (GABA), alanine, glycine, glutamate, and aspartate), with nanomolar and subnanomolar detection limits. Two of the amino acids (GABA and glutamate) were analysed in parallel by conventional high-performance liquid chromatography (HPLC) in order to directly compare the two analytical methods. Other CE methods for analysis of microdialysate have been previously described, and this improved method offers greater sensitivity, ease of use, and the possibility to monitor several amino acids simultaneously. By using this technique together with an optimised form of microdialysis technique, the tiny sample consumption and the improved detection limits permit the detection of fast and transient transmitter changes.

  8. Simultaneous UHPLC-UV analysis of hydroxychloroquine, minocycline and doxycycline from serum samples for the therapeutic drug monitoring of Q fever and Whipple's disease.

    PubMed

    Armstrong, Nicholas; Richez, Magali; Raoult, Didier; Chabriere, Eric

    2017-08-15

    A fast UHPLC-UV method was developed for the simultaneous analysis of Hydroxychloroquine, Minocycline and Doxycycline drugs from 100μL of human serum samples. Serum samples were extracted by liquid-liquid extraction and injected into a phenyl hexyl reverse phase column. Compounds were separated using a mobile phase linear gradient and monitored by UV detection at 343nm. Chloroquine and Oxytetracycline were used as internal standards. Lower and upper limits of quantifications, as well as the other levels of calibration, were validated with acceptable accuracy (<15% deviation) and precision (<15% coefficient of variation) according to the European Medicines Agency guidelines. This new method enables cost and time reduction and was considered suitable for the clinical laboratory. It is the first published assay for the therapeutic drug monitoring of patients diagnosed with Q fever or Whipple's disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Quantitative analysis of glycosaminoglycans, chondroitin/dermatan sulfate, hyaluronic acid, heparan sulfate, and keratan sulfate by liquid chromatography-electrospray ionization-tandem mass spectrometry.

    PubMed

    Osago, Harumi; Shibata, Tomoko; Hara, Nobumasa; Kuwata, Suguru; Kono, Michihaya; Uchio, Yuji; Tsuchiya, Mikako

    2014-12-15

    We developed a method using liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) with a selected reaction monitoring (SRM) mode for simultaneous quantitative analysis of glycosaminoglycans (GAGs). Using one-shot analysis with our MS/MS method, we demonstrated the simultaneous quantification of a total of 23 variously sulfated disaccharides of four GAG classes (8 chondroitin/dermatan sulfates, 1 hyaluronic acid, 12 heparan sulfates, and 2 keratan sulfates) with a sensitivity of less than 0.5 pmol within 20 min. We showed the differences in the composition of GAG classes and the sulfation patterns between porcine articular cartilage and yellow ligament. In addition to the internal disaccharides described above, some saccharides derived from the nonreducing terminal were detected simultaneously. The simultaneous quantification of both internal and nonreducing terminal saccharides could be useful to estimate the chain length of GAGs. This method would help to establish comprehensive "GAGomic" analysis of biological tissues. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. A Wearable EEG-HEG-HRV Multimodal System With Simultaneous Monitoring of tES for Mental Health Management.

    PubMed

    Ha, Unsoo; Lee, Yongsu; Kim, Hyunki; Roh, Taehwan; Bae, Joonsung; Kim, Changhyeon; Yoo, Hoi-Jun

    2015-12-01

    A multimodal mental management system in the shape of the wearable headband and earplugs is proposed to monitor electroencephalography (EEG), hemoencephalography (HEG) and heart rate variability (HRV) for accurate mental health monitoring. It enables simultaneous transcranial electrical stimulation (tES) together with real-time monitoring. The total weight of the proposed system is less than 200 g. The multi-loop low-noise amplifier (MLLNA) achieves over 130 dB CMRR for EEG sensing and the capacitive correlated-double sampling transimpedance amplifier (CCTIA) has low-noise characteristics for HEG and HRV sensing. Measured three-physiology domains such as neural, vascular and autonomic domain signals are combined with canonical correlation analysis (CCA) and temporal kernel canonical correlation analysis (tkCCA) algorithm to find the neural-vascular-autonomic coupling. It supports highly accurate classification with the 19% maximum improvement with multimodal monitoring. For the multi-channel stimulation functionality, after-effects maximization monitoring and sympathetic nerve disorder monitoring, the stimulator is designed as reconfigurable. The 3.37 × 2.25 mm(2) chip has 2-channel EEG sensor front-end, 2-channel NIRS sensor front-end, NIRS current driver to drive dual-wavelength VCSEL and 6-b DAC current source for tES mode. It dissipates 24 mW with 2 mA stimulation current and 5 mA NIRS driver current.

  11. Simultaneous long-term monitoring of LS I +61°303 by OVRO and Fermi-LAT

    NASA Astrophysics Data System (ADS)

    Jaron, Frédéric; Massi, Maria; Kiehlmann, Sebastian; Hovatta, Talvikki

    2018-07-01

    Previous long-term monitorings of the γ-ray-loud X-ray binary LS I +61°303 have revealed the presence of a long-term modulation of ˜4.5 yr. After 9 yr of simultaneous monitoring of LS I +61°303 by the Owens Valley Radio Observatory and the Fermi-LAT, two cycles of the long-term period are now available. Here we perform timing analysis on the radio and the γ-ray light curves. We confirm the presence of previously detected periodicities at both radio and GeV γ-ray wavelengths. Moreover, we discover an offset of the long-term modulation between radio and γ-ray data which could imply different locations of the radio (15 GHz) and GeV emission along the precessing jet.

  12. Multiplexed fluorescence detector system for capillary electrophoresis

    DOEpatents

    Yeung, E.S.; Taylor, J.A.

    1996-03-12

    A fluorescence detection system for capillary electrophoresis is provided wherein the detection system can simultaneously excite fluorescence and substantially simultaneously monitor separations in multiple capillaries. This multiplexing approach involves laser irradiation of a sample in a plurality of capillaries through optical fibers that are coupled individually with the capillaries. The array is imaged orthogonally through a microscope onto a charge-coupled device camera for signal analysis. 14 figs.

  13. Multiplexed fluorescence detector system for capillary electrophoresis

    DOEpatents

    Yeung, E.S.; Taylor, J.A.

    1994-06-28

    A fluorescence detection system for capillary electrophoresis is provided wherein the detection system can simultaneously excite fluorescence and substantially simultaneously monitor separations in multiple capillaries. This multiplexing approach involves laser irradiation of a sample in a plurality of capillaries through optical fibers that are coupled individually with the capillaries. The array is imaged orthogonally through a microscope onto a charge-coupled device camera for signal analysis. 14 figures.

  14. Preliminary data for the 20 May 1974, simultaneous evaluation of remote sensors experiment. [water pollution monitoring

    NASA Technical Reports Server (NTRS)

    Johnson, R. W.; Batten, C. E.; Bowker, D. E.; Bressette, W. E.; Grew, G. W.

    1975-01-01

    Several remote sensors were simultaneously used to collect data over the tidal James River from Hopewell to Norfolk, Virginia. Sensors evaluated included the Multichannel-Ocean Color Sensor, multispectral scanners, and multispectral photography. Ground truth measurements and remotely sensed data are given. Preliminary analysis indicates that suspended sediment and concentrated industrial effluent are observable from all sensors.

  15. Multiplexed fluorescence detector system for capillary electrophoresis

    DOEpatents

    Yeung, Edward S.; Taylor, John A.

    1996-03-12

    A fluorescence detection system for capillary electrophoresis is provided wherein the detection system can simultaneously excite fluorescence and substantially simultaneously monitor separations in multiple capillaries. This multiplexing approach involves laser irradiation of a sample in a plurality of capillaries through optical fibers that are coupled individually with the capillaries. The array is imaged orthogonally through a microscope onto a charge-coupled device camera for signal analysis.

  16. Multiplexed fluorescence detector system for capillary electrophoresis

    DOEpatents

    Yeung, Edward S.; Taylor, John A.

    1994-06-28

    A fluorescence detection system for capillary electrophoresis is provided wherein the detection system can simultaneously excite fluorescence and substantially simultaneously monitor separations in multiple capillaries. This multiplexing approach involves laser irradiation of a sample in a plurality of capillaries through optical fibers that are coupled individually with the capillaries. The array is imaged orthogonally through a microscope onto a charge-coupled device camera for signal analysis.

  17. Simultaneous real-time monitoring of multiple cortical systems.

    PubMed

    Gupta, Disha; Jeremy Hill, N; Brunner, Peter; Gunduz, Aysegul; Ritaccio, Anthony L; Schalk, Gerwin

    2014-10-01

    Real-time monitoring of the brain is potentially valuable for performance monitoring, communication, training or rehabilitation. In natural situations, the brain performs a complex mix of various sensory, motor or cognitive functions. Thus, real-time brain monitoring would be most valuable if (a) it could decode information from multiple brain systems simultaneously, and (b) this decoding of each brain system were robust to variations in the activity of other (unrelated) brain systems. Previous studies showed that it is possible to decode some information from different brain systems in retrospect and/or in isolation. In our study, we set out to determine whether it is possible to simultaneously decode important information about a user from different brain systems in real time, and to evaluate the impact of concurrent activity in different brain systems on decoding performance. We study these questions using electrocorticographic signals recorded in humans. We first document procedures for generating stable decoding models given little training data, and then report their use for offline and for real-time decoding from 12 subjects (six for offline parameter optimization, six for online experimentation). The subjects engage in tasks that involve movement intention, movement execution and auditory functions, separately, and then simultaneously. Main Results: Our real-time results demonstrate that our system can identify intention and movement periods in single trials with an accuracy of 80.4% and 86.8%, respectively (where 50% would be expected by chance). Simultaneously, the decoding of the power envelope of an auditory stimulus resulted in an average correlation coefficient of 0.37 between the actual and decoded power envelopes. These decoders were trained separately and executed simultaneously in real time. This study yielded the first demonstration that it is possible to decode simultaneously the functional activity of multiple independent brain systems. Our comparison of univariate and multivariate decoding strategies, and our analysis of the influence of their decoding parameters, provides benchmarks and guidelines for future research on this topic.

  18. Simultaneous Real-Time Monitoring of Multiple Cortical Systems

    PubMed Central

    Gupta, Disha; Hill, N. Jeremy; Brunner, Peter; Gunduz, Aysegul; Ritaccio, Anthony L.; Schalk, Gerwin

    2014-01-01

    Objective Real-time monitoring of the brain is potentially valuable for performance monitoring, communication, training or rehabilitation. In natural situations, the brain performs a complex mix of various sensory, motor, or cognitive functions. Thus, real-time brain monitoring would be most valuable if (a) it could decode information from multiple brain systems simultaneously, and (b) this decoding of each brain system were robust to variations in the activity of other (unrelated) brain systems. Previous studies showed that it is possible to decode some information from different brain systems in retrospect and/or in isolation. In our study, we set out to determine whether it is possible to simultaneously decode important information about a user from different brain systems in real time, and to evaluate the impact of concurrent activity in different brain systems on decoding performance. Approach We study these questions using electrocorticographic (ECoG) signals recorded in humans. We first document procedures for generating stable decoding models given little training data, and then report their use for offline and for real-time decoding from 12 subjects (6 for offline parameter optimization, 6 for online experimentation). The subjects engage in tasks that involve movement intention, movement execution and auditory functions, separately, and then simultaneously. Main results Our real-time results demonstrate that our system can identify intention and movement periods in single trials with an accuracy of 80.4% and 86.8%, respectively (where 50% would be expected by chance). Simultaneously, the decoding of the power envelope of an auditory stimulus resulted in an average correlation coefficient of 0.37 between the actual and decoded power envelope. These decoders were trained separately and executed simultaneously in real time. Significance This study yielded the first demonstration that it is possible to decode simultaneously the functional activity of multiple independent brain systems. Our comparison of univariate and multivariate decoding strategies, and our analysis of the influence of their decoding parameters, provides benchmarks and guidelines for future research on this topic. PMID:25080161

  19. Method and apparatus for simultaneous spectroelectrochemical analysis

    DOEpatents

    Chatterjee, Sayandev; Bryan, Samuel A; Schroll, Cynthia A; Heineman, William R

    2013-11-19

    An apparatus and method of simultaneous spectroelectrochemical analysis is disclosed. A transparent surface is provided. An analyte solution on the transparent surface is contacted with a working electrode and at least one other electrode. Light from a light source is focused on either a surface of the working electrode or the analyte solution. The light reflected from either the surface of the working electrode or the analyte solution is detected. The potential of the working electrode is adjusted, and spectroscopic changes of the analyte solution that occur with changes in thermodynamic potentials are monitored.

  20. Droplet monitoring probe

    NASA Technical Reports Server (NTRS)

    Baughman, J. R.; Thys, P. C.

    1973-01-01

    A droplet monitoring system is disclosed for analysis of mixed-phase fluid flow in development of gas turbines. The system uses a probe comprising two electrical wires spaced a known distance apart and connected at one end to means for establishing a dc potential between the wires. A drop in the fluid stream momentarily contacting both wires simultaneously causes and electrical signal which is amplified, detected and counted.

  1. Continous Monitoring of Melt Composition

    NASA Technical Reports Server (NTRS)

    Frazer, R. E.; Andrews, T. W.

    1984-01-01

    Compositions of glasses and alloys analyzed and corrected in real time. Spectral analysis and temperature measurement performed simultaneously on molten material in container, such as open-hearth furnace, crucible or tank of continuous furnace. Speed of analysis makes it possible to quickly measure concentration of volatile elements depleted by prolonged heating.

  2. A method for simultaneous linear optics and coupling correction for storage rings with turn-by-turn beam position monitor data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Xi; Huang, Xiaobiao

    2016-05-13

    Here, we propose a method to simultaneously correct linear optics errors and linear coupling for storage rings using turn-by-turn (TbT) beam position monitor (BPM) data. The independent component analysis (ICA) method is used to isolate the betatron normal modes from the measured TbT BPM data. The betatron amplitudes and phase advances of the projections of the normal modes on the horizontal and vertical planes are then extracted, which, combined with dispersion measurement, are used to fit the lattice model. The fitting results are used for lattice correction. Finally, the method has been successfully demonstrated on the NSLS-II storage ring.

  3. A method for simultaneous linear optics and coupling correction for storage rings with turn-by-turn beam position monitor data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Xi; Huang, Xiaobiao

    2016-08-01

    We propose a method to simultaneously correct linear optics errors and linear coupling for storage rings using turn-by-turn (TbT) beam position monitor (BPM) data. The independent component analysis (ICA) method is used to isolate the betatron normal modes from the measured TbT BPM data. The betatron amplitudes and phase advances of the projections of the normal modes on the horizontal and vertical planes are then extracted, which, combined with dispersion measurement, are used to fit the lattice model. Furthermore, the fitting results are used for lattice correction. Our method has been successfully demonstrated on the NSLS-II storage ring.

  4. A method for simultaneous linear optics and coupling correction for storage rings with turn-by-turn beam position monitor data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Xi; Huang, Xiaobiao

    2016-08-01

    We propose a method to simultaneously correct linear optics errors and linear coupling for storage rings using turn-by-turn (TbT) beam position monitor (BPM) data. The independent component analysis (ICA) method is used to isolate the betatron normal modes from the measured TbT BPM data. The betatron amplitudes and phase advances of the projections of the normal modes on the horizontal and vertical planes are then extracted, which, combined with dispersion measurement, are used to fit the lattice model. The fitting results are used for lattice correction. The method has been successfully demonstrated on the NSLS-II storage ring.

  5. Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis

    DOE PAGES

    Gao, Wei; Emaminejad, Sam; Nyein, Hnin Yin Yin; ...

    2016-01-27

    We report that wearable sensor technologies are essential to the realization of personalized medicine through continuously monitoring an individual’s state of health. Sampling human sweat, which is rich in physiological information13, could enable non-invasive monitoring. Previously reported sweat-based and other noninvasive biosensors either can only monitor a single analyte at a time or lack on-site signal processing circuitry and sensor calibration mechanisms for accurate analysis of the physiological state14–18. Given the complexity of sweat secretion, simultaneous and multiplexed screening of target biomarkers is critical and requires full system integration to ensure the accuracy of measurements. Here we present a mechanicallymore » flexible and fully integrated (that is, no external analysis is needed) sensor array for multiplexed in situ perspiration analysis, which simultaneously and selectively measures sweat metabolites (such as glucose and lactate) and electrolytes (such as sodium and potassium ions), as well as the skin temperature (to calibrate the response of the sensors). Lastly, our work bridges the technological gap between signal transduction, conditioning (amplification and filtering), processing and wireless transmission in wearable biosensors by merging plasticbased sensors that interface with the skin with silicon integrated circuits consolidated on a flexible circuit board for complex signal processing.« less

  6. Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gao, Wei; Emaminejad, Sam; Nyein, Hnin Yin Yin

    We report that wearable sensor technologies are essential to the realization of personalized medicine through continuously monitoring an individual’s state of health. Sampling human sweat, which is rich in physiological information13, could enable non-invasive monitoring. Previously reported sweat-based and other noninvasive biosensors either can only monitor a single analyte at a time or lack on-site signal processing circuitry and sensor calibration mechanisms for accurate analysis of the physiological state14–18. Given the complexity of sweat secretion, simultaneous and multiplexed screening of target biomarkers is critical and requires full system integration to ensure the accuracy of measurements. Here we present a mechanicallymore » flexible and fully integrated (that is, no external analysis is needed) sensor array for multiplexed in situ perspiration analysis, which simultaneously and selectively measures sweat metabolites (such as glucose and lactate) and electrolytes (such as sodium and potassium ions), as well as the skin temperature (to calibrate the response of the sensors). Lastly, our work bridges the technological gap between signal transduction, conditioning (amplification and filtering), processing and wireless transmission in wearable biosensors by merging plasticbased sensors that interface with the skin with silicon integrated circuits consolidated on a flexible circuit board for complex signal processing.« less

  7. Flow cytometer jet monitor system

    DOEpatents

    Van den Engh, Ger

    1997-01-01

    A direct jet monitor illuminates the jet of a flow cytometer in a monitor wavelength band which is substantially separate from the substance wavelength band. When a laser is used to cause fluorescence of the substance, it may be appropriate to use an infrared source to illuminate the jet and thus optically monitor the conditions within the jet through a CCD camera or the like. This optical monitoring may be provided to some type of controller or feedback system which automatically changes either the horizontal location of the jet, the point at which droplet separation occurs, or some other condition within the jet in order to maintain optimum conditions. The direct jet monitor may be operated simultaneously with the substance property sensing and analysis system so that continuous monitoring may be achieved without interfering with the substance data gathering and may be configured so as to allow the front of the analysis or free fall area to be unobstructed during processing.

  8. Soldier-Based Assessment of a Dual-Row Tactor Display during Simultaneous Navigational and Robot-Monitoring Tasks

    DTIC Science & Technology

    2015-08-01

    Navigational and Robot -Monitoring Tasks by Gina Pomranky-Hartnett, Linda R Elliott, Bruce JP Mortimer, Greg R Mort, Rodger A Pettitt, and Gary A...Tactor Display during Simultaneous Navigational and Robot -Monitoring Tasks by Gina Pomranky-Hartnett, Linda R Elliott, and Rodger A Pettitt...2014–31 March 2015 4. TITLE AND SUBTITLE Soldier-Based Assessment of a Dual-Row Tactor Display during Simultaneous Navigational and Robot -Monitoring

  9. Energy Response Function of CALET Gamma Ray Burst Monitor

    NASA Astrophysics Data System (ADS)

    Yamada, Y.; Sakamoto, T.; Yoshida, A.; Calet Collaboration

    2016-10-01

    We will explain the development of the CGBM energy response function. We will also show the spectral analysis results of CGBM using our developed energy response function for simultaneously detected bright GRBs by other GRB detectors.

  10. Multichannel audio monitor for detecting electrical signals.

    PubMed

    Friesen, W O; Stent, G S

    1978-12-01

    The multichannel audio monitor (MUCAM) permits the simultaneous auditory monitoring of concurrent trains of electrical signals generated by as many as eight different sources. The basic working principle of this device is the modulation of the amplitude of a given pure tone by the incoming signals of each input channel. The MUCAM thus converts a complex, multichannel, temporal signal sequence into a musical melody suitable for instant, subliminal pattern analysis by the human ear. Neurophysiological experiments requiring multi-electrode recordings have provided one useful application of the MUCAM.

  11. Multilevel semantic analysis and problem-solving in the flight domain

    NASA Technical Reports Server (NTRS)

    Chien, R. T.; Chen, D. C.; Ho, W. P. C.; Pan, Y. C.

    1982-01-01

    A computer based cockpit system which is capable of assisting the pilot in such important tasks as monitoring, diagnosis, and trend analysis was developed. The system is properly organized and is endowed with a knowledge base so that it enhances the pilot's control over the aircraft while simultaneously reducing his workload.

  12. Calibration and performance of synchronous SIM/scan mode for simultaneous targeted and discovery (non-targeted) analysis of exhaled breath samples from firefighters

    EPA Science Inventory

    Traditionally, gas chromatography – mass spectrometry (GC-MS) analysis has used a targeted approach called selected ion monitoring (SIM) to quantify specific compounds that may have adverse health effects. Due to method limitations and the constraints of preparing duplicat...

  13. FTIR MONITORING OF THE VENTILATION AIR OF CRITICAL BUILDINGS

    EPA Science Inventory

    Fourier transform infrared (FTIR) spectroscopy has been used for detailed analysis of environmental and industrial process samples for many years. FTIR spectrometers have the capability of measuring multiple compounds simultaneously, thus providing an advantage over most other me...

  14. Toward the improvement in fetal monitoring during labor with the inclusion of maternal heart rate analysis.

    PubMed

    Gonçalves, Hernâni; Pinto, Paula; Silva, Manuela; Ayres-de-Campos, Diogo; Bernardes, João

    2016-04-01

    Fetal heart rate (FHR) monitoring is used routinely in labor, but conventional methods have a limited capacity to detect fetal hypoxia/acidosis. An exploratory study was performed on the simultaneous assessment of maternal heart rate (MHR) and FHR variability, to evaluate their evolution during labor and their capacity to detect newborn acidemia. MHR and FHR were simultaneously recorded in 51 singleton term pregnancies during the last two hours of labor and compared with newborn umbilical artery blood (UAB) pH. Linear/nonlinear indices were computed separately for MHR and FHR. Interaction between MHR and FHR was quantified through the same indices on FHR-MHR and through their correlation and cross-entropy. Univariate and bivariate statistical analysis included nonparametric confidence intervals and statistical tests, receiver operating characteristic curves and linear discriminant analysis. Progression of labor was associated with a significant increase in most MHR and FHR linear indices, whereas entropy indices decreased. FHR alone and in combination with MHR as FHR-MHR evidenced the highest auROC values for prediction of fetal acidemia, with 0.76 and 0.88 for the UAB pH thresholds 7.20 and 7.15, respectively. The inclusion of MHR on bivariate analysis achieved sensitivity and specificity values of nearly 100 and 89.1%, respectively. These results suggest that simultaneous analysis of MHR and FHR may improve the identification of fetal acidemia compared with FHR alone, namely during the last hour of labor.

  15. The Neural Bases of Event Monitoring across Domains: a Simultaneous ERP-fMRI Study

    PubMed Central

    Tarantino, Vincenza; Mazzonetto, Ilaria; Formica, Silvia; Causin, Francesco; Vallesi, Antonino

    2017-01-01

    The ability to check and evaluate the environment over time with the aim to detect the occurrence of target stimuli is supported by sustained/tonic as well as transient/phasic control processes, which overall might be referred to as event monitoring. The neural underpinning of sustained attentional control processes involves a fronto-parietal network. However, it has not been well-defined yet whether this cortical circuit acts irrespective of the specific material to be monitored and whether this mediates sustained as well as transient monitoring processes. In the current study, the functional activity of brain during an event monitoring task was investigated and compared between two cognitive domains, whose processing is mediated by differently lateralized areas. Namely, participants were asked to monitor sequences of either faces (supported by right-hemisphere regions) or tools (left-hemisphere). In order to disentangle sustained from transient components of monitoring, a simultaneous EEG-fMRI technique was adopted within a block design. When contrasting monitoring versus control blocks, the conventional fMRI analysis revealed the sustained involvement of bilateral fronto-parietal regions, in both task domains. Event-related potentials (ERPs) showed a more positive amplitude over frontal sites in monitoring compared to control blocks, providing evidence of a transient monitoring component. The joint ERP-fMRI analysis showed that, in the case of face monitoring, this transient component relies on right-lateralized areas, including the inferior parietal lobule and the middle frontal gyrus. In the case of tools, no fronto-parietal areas correlated with the transient ERP activity, suggesting that in this domain phasic monitoring processes were masked by tonic ones. Overall, the present findings highlight the role of bilateral fronto-parietal regions in sustained monitoring, independently of the specific task requirements, and suggest that right-lateralized areas subtend transient monitoring processes, at least in some task contexts. PMID:28785212

  16. Simultaneous and quantitative monitoring of co-cultured Pseudomonas aeruginosa and Staphylococcus aureus with antibiotics on a diffusometric platform

    NASA Astrophysics Data System (ADS)

    Chung, Chih-Yao; Wang, Jhih-Cheng; Chuang, Han-Sheng

    2017-04-01

    Successful treatments against bacterial infections depend on antimicrobial susceptibility testing (AST). However, conventional AST requires more than 24 h to obtain an outcome, thereby contributing to high patient mortality. An antibiotic therapy based on experiences is therefore necessary for saving lives and escalating the emergence of multidrug-resistant pathogens. Accordingly, a fast and effective drug screen is necessary for the appropriate administration of antibiotics. The mixed pathogenic nature of infectious diseases emphasizes the need to develop an assay system for polymicrobial infections. On this basis, we present a novel technique for simultaneous and quantitative monitoring of co-cultured microorganisms by coupling optical diffusometry with bead-based immunoassays. This simple integration simultaneously achieves a rapid AST analysis for two pathogens. Triple color particles were simultaneously recorded and subsequently analyzed by functionalizing different fluorescent color particles with dissimilar pathogen-specific antibodies. Results suggested that the effect of the antibiotic, gentamicin, on co-cultured Pseudomonas aeruginosa and Staphylococcus aureus was effectively distinguished by the proposed technique. This study revealed a multiplexed and time-saving (within 2 h) platform with a small sample volume (~0.5 μL) and a low initial bacterial count (50 CFU per droplet, ~105 CFU/mL) for continuously monitoring the growth of co-cultured microorganisms. This technique provides insights into timely therapies against polymicrobial diseases in the near future.

  17. Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis.

    PubMed

    Gao, Wei; Emaminejad, Sam; Nyein, Hnin Yin Yin; Challa, Samyuktha; Chen, Kevin; Peck, Austin; Fahad, Hossain M; Ota, Hiroki; Shiraki, Hiroshi; Kiriya, Daisuke; Lien, Der-Hsien; Brooks, George A; Davis, Ronald W; Javey, Ali

    2016-01-28

    Wearable sensor technologies are essential to the realization of personalized medicine through continuously monitoring an individual's state of health. Sampling human sweat, which is rich in physiological information, could enable non-invasive monitoring. Previously reported sweat-based and other non-invasive biosensors either can only monitor a single analyte at a time or lack on-site signal processing circuitry and sensor calibration mechanisms for accurate analysis of the physiological state. Given the complexity of sweat secretion, simultaneous and multiplexed screening of target biomarkers is critical and requires full system integration to ensure the accuracy of measurements. Here we present a mechanically flexible and fully integrated (that is, no external analysis is needed) sensor array for multiplexed in situ perspiration analysis, which simultaneously and selectively measures sweat metabolites (such as glucose and lactate) and electrolytes (such as sodium and potassium ions), as well as the skin temperature (to calibrate the response of the sensors). Our work bridges the technological gap between signal transduction, conditioning (amplification and filtering), processing and wireless transmission in wearable biosensors by merging plastic-based sensors that interface with the skin with silicon integrated circuits consolidated on a flexible circuit board for complex signal processing. This application could not have been realized using either of these technologies alone owing to their respective inherent limitations. The wearable system is used to measure the detailed sweat profile of human subjects engaged in prolonged indoor and outdoor physical activities, and to make a real-time assessment of the physiological state of the subjects. This platform enables a wide range of personalized diagnostic and physiological monitoring applications.

  18. Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis

    NASA Astrophysics Data System (ADS)

    Gao, Wei; Emaminejad, Sam; Nyein, Hnin Yin Yin; Challa, Samyuktha; Chen, Kevin; Peck, Austin; Fahad, Hossain M.; Ota, Hiroki; Shiraki, Hiroshi; Kiriya, Daisuke; Lien, Der-Hsien; Brooks, George A.; Davis, Ronald W.; Javey, Ali

    2016-01-01

    Wearable sensor technologies are essential to the realization of personalized medicine through continuously monitoring an individual’s state of health. Sampling human sweat, which is rich in physiological information, could enable non-invasive monitoring. Previously reported sweat-based and other non-invasive biosensors either can only monitor a single analyte at a time or lack on-site signal processing circuitry and sensor calibration mechanisms for accurate analysis of the physiological state. Given the complexity of sweat secretion, simultaneous and multiplexed screening of target biomarkers is critical and requires full system integration to ensure the accuracy of measurements. Here we present a mechanically flexible and fully integrated (that is, no external analysis is needed) sensor array for multiplexed in situ perspiration analysis, which simultaneously and selectively measures sweat metabolites (such as glucose and lactate) and electrolytes (such as sodium and potassium ions), as well as the skin temperature (to calibrate the response of the sensors). Our work bridges the technological gap between signal transduction, conditioning (amplification and filtering), processing and wireless transmission in wearable biosensors by merging plastic-based sensors that interface with the skin with silicon integrated circuits consolidated on a flexible circuit board for complex signal processing. This application could not have been realized using either of these technologies alone owing to their respective inherent limitations. The wearable system is used to measure the detailed sweat profile of human subjects engaged in prolonged indoor and outdoor physical activities, and to make a real-time assessment of the physiological state of the subjects. This platform enables a wide range of personalized diagnostic and physiological monitoring applications.

  19. HPLC analysis of 6-mercaptopurine and metabolites in extracellular body fluids.

    PubMed

    Rudy, J L; Argyle, J C; Winick, N; Van Dreal, P

    1988-09-01

    A convenient HPLC assay, which allows for the simultaneous measurement in extracellular fluids of 6-mercaptopurine and four of its metabolites, 6-thioguanine, 6-mercaptopurine riboside, 6-thioxanthine and 6-thiouric acid is described. Solid phase extraction allows for the clean isolation of analytes from plasma, urine or cerebrospinal fluid. The simultaneous determination of 6-mercaptopurine and some of its major metabolites in extracellular fluids may contribute to the monitoring of patient compliance, bioavailability, and individual variation in metabolism and absorption.

  20. Simultaneous Power Deposition Detection of Two EC Beams with the BIS Analysis in Moving TCV Plasmas

    NASA Astrophysics Data System (ADS)

    Curchod, L.; Pochelon, A.; Decker, J.; Felici, F.; Goodman, T. P.; Moret, J.-M.; Paley, J. I.

    2009-11-01

    Modulation of power amplitude is a widespread to determine the radial absorption profile of externally launched power in fusion plasmas. There are many techniques to analyze the plasma response to such a modulation. The break-in-slope (BIS) analysis can draw an estimated power deposition profile for each power step up. In this paper, the BIS analysis is used to monitor the power deposition location of one or two EC power beams simultaneously in a non-stationary plasma being displaced vertically in the TCV tokamak vessel. Except from radial discrepancies, the results have high time resolution and compare well with simulations from the R2D2-C3PO-LUKE ray-tracing and Fokker-Planck code suite.

  1. An internet-based wearable watch-over system for elderly and disabled utilizing EMG and accelerometer.

    PubMed

    Kishimoto, M; Yoshida, T; Hayasaka, T; Mori, D; Imai, Y; Matsuki, N; Ishikawa, T; Yamaguchi, T

    2009-01-01

    An effective way for preventing injuries and diseases among the elderly is to monitor their daily lives. In this regard, we propose the use of a "Hyper Hospital Network", which is an information support system for elderly people and patients. In the current study, we developed a wearable system for monitoring electromyography (EMG) and acceleration using the Hyper Hospital Network plan. The current system is an upgraded version of our previous system for gait analysis (Yoshida et al. [13], Telemedicine and e-Health 13 703-714), and lets us monitor decreases in exercise and the presence of a hemiplegic gait more accurately. To clarify the capabilities and reliability of the system, we performed three experimental evaluations: one to verify the performance of the wearable system, a second to detect a hemiplegic gait, and a third to monitor EMG and accelerations simultaneously. Our system successfully detected a lack of exercise by monitoring the iEMG in healthy volunteers. Moreover, by using EMG and acceleration signals simultaneously, the reliability of the Hampering Index (HI) for detecting hemiplegia walking was improved significantly. The present study provides useful knowledge for the development of a wearable computer designed to monitor the physical conditions of older persons and patients.

  2. Agreement of Bioreactance Cardiac Output Monitoring With Thermodilution During Hemorrhagic Shock and Resuscitation in Adult Swine.

    PubMed

    Berlin, David A; Peprah-Mensah, Harrison; Manoach, Seth; Heerdt, Paul M

    2017-02-01

    The study tests the hypothesis that noninvasive cardiac output monitoring based upon bioreactance (Cheetah Medical, Portland, OR) has acceptable agreement with intermittent bolus thermodilution over a wide range of cardiac output in an adult porcine model of hemorrhagic shock and resuscitation. Prospective laboratory animal investigation. Preclinical university laboratory. Eight ~ 50 kg Yorkshire swine with a femoral artery catheter for blood pressure measurement and a pulmonary artery catheter for bolus thermodilution. With the pigs anesthetized and mechanically ventilated, 40 mL/kg of blood was removed yielding marked hypotension and a rise in plasma lactate. After 60 minutes, pigs were resuscitated with shed blood and crystalloid. Noninvasive cardiac output monitoring and intermittent thermodilution cardiac output were simultaneously measured at nine time points spanning baseline, hemorrhage, and resuscitation. Simultaneous noninvasive cardiac output monitoring and thermodilution measurements of cardiac output were compared by Bland-Altman analysis. A plot was constructed using the difference of each paired measurement expressed as a percentage of the mean of the pair plotted against the mean of the pair. Percent bias was used to scale the differences in the measurements for the magnitude of the cardiac output. Method concordance was assessed from a four-quadrant plot with a 15% zone of exclusion. Overall, noninvasive cardiac output monitoring percent bias was 1.47% (95% CI, -2.5 to 5.4) with limits of agreement of upper equal to 33.4% (95% CI, 26.5-40.2) and lower equal to -30.4% (95% CI, -37.3 to -23.6). Trending analysis demonstrated a 97% concordance between noninvasive cardiac output monitoring and thermodilution cardiac output. Over the wide range of cardiac output produced by hemorrhage and resuscitation in large pigs, noninvasive cardiac output monitoring has acceptable agreement with thermodilution cardiac output.

  3. In vivo bioluminescence imaging of cell differentiation in biomaterials: a platform for scaffold development.

    PubMed

    Bagó, Juli R; Aguilar, Elisabeth; Alieva, Maria; Soler-Botija, Carolina; Vila, Olaia F; Claros, Silvia; Andrades, José A; Becerra, José; Rubio, Nuria; Blanco, Jerónimo

    2013-03-01

    In vivo testing is a mandatory last step in scaffold development. Agile longitudinal noninvasive real-time monitoring of stem cell behavior in biomaterials implanted in live animals should facilitate the development of scaffolds for tissue engineering. We report on a noninvasive bioluminescence imaging (BLI) procedure for simultaneous monitoring of changes in the expression of multiple genes to evaluate scaffold performance in vivo. Adipose tissue-derived stromal mensenchymal cells were dually labeled with Renilla red fluorescent protein and firefly green fluorescent protein chimeric reporters regulated by cytomegalovirus and tissue-specific promoters, respectively. Labeled cells were induced to differentiate in vitro and in vivo, by seeding in demineralized bone matrices (DBMs) and monitored by BLI. Imaging results were validated by RT-polymerase chain reaction and histological procedures. The proposed approach improves molecular imaging and measurement of changes in gene expression of cells implanted in live animals. This procedure, applicable to the simultaneous analysis of multiple genes from cells seeded in DBMs, should facilitate engineering of scaffolds for tissue repair.

  4. In Vivo Bioluminescence Imaging of Cell Differentiation in Biomaterials: A Platform for Scaffold Development

    PubMed Central

    Bagó, Juli R.; Aguilar, Elisabeth; Alieva, Maria; Soler-Botija, Carolina; Vila, Olaia F.; Claros, Silvia; Andrades, José A.; Becerra, José; Rubio, Nuria

    2013-01-01

    In vivo testing is a mandatory last step in scaffold development. Agile longitudinal noninvasive real-time monitoring of stem cell behavior in biomaterials implanted in live animals should facilitate the development of scaffolds for tissue engineering. We report on a noninvasive bioluminescence imaging (BLI) procedure for simultaneous monitoring of changes in the expression of multiple genes to evaluate scaffold performance in vivo. Adipose tissue-derived stromal mensenchymal cells were dually labeled with Renilla red fluorescent protein and firefly green fluorescent protein chimeric reporters regulated by cytomegalovirus and tissue-specific promoters, respectively. Labeled cells were induced to differentiate in vitro and in vivo, by seeding in demineralized bone matrices (DBMs) and monitored by BLI. Imaging results were validated by RT-polymerase chain reaction and histological procedures. The proposed approach improves molecular imaging and measurement of changes in gene expression of cells implanted in live animals. This procedure, applicable to the simultaneous analysis of multiple genes from cells seeded in DBMs, should facilitate engineering of scaffolds for tissue repair. PMID:23013334

  5. Looking towards label-free biomolecular interaction analysis in a high-throughput format: a review of new surface plasmon resonance technologies.

    PubMed

    Boozer, Christina; Kim, Gibum; Cong, Shuxin; Guan, Hannwen; Londergan, Timothy

    2006-08-01

    Surface plasmon resonance (SPR) biosensors have enabled a wide range of applications in which researchers can monitor biomolecular interactions in real time. Owing to the fact that SPR can provide affinity and kinetic data, unique features in applications ranging from protein-peptide interaction analysis to cellular ligation experiments have been demonstrated. Although SPR has historically been limited by its throughput, new methods are emerging that allow for the simultaneous analysis of many thousands of interactions. When coupled with new protein array technologies, high-throughput SPR methods give users new and improved methods to analyze pathways, screen drug candidates and monitor protein-protein interactions.

  6. Analysis and Processing the 3D-Range-Image-Data for Robot Monitoring

    NASA Astrophysics Data System (ADS)

    Kohoutek, Tobias

    2008-09-01

    Industrial robots are commonly used for physically stressful jobs in complex environments. In any case collisions with heavy and high dynamic machines need to be prevented. For this reason the operational range has to be monitored precisely, reliably and meticulously. The advantage of the SwissRanger® SR-3000 is that it delivers intensity images and 3D-information simultaneously of the same scene that conveniently allows 3D-monitoring. Due to that fact automatic real time collision prevention within the robots working space is possible by working with 3D-coordinates.

  7. Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis

    PubMed Central

    Nyein, Hnin Yin Yin; Challa, Samyuktha; Chen, Kevin; Peck, Austin; Fahad, Hossain M.; Ota, Hiroki; Shiraki, Hiroshi; Kiriya, Daisuke; Lien, Der-Hsien; Brooks, George A.; Davis, Ronald W.; Javey, Ali

    2016-01-01

    Wearable sensor technologies are essential to the realization of personalized medicine through continuously monitoring an individual's state of health1–12. Sampling human sweat, which is rich in physiological information13, could enable non-invasive monitoring. Previously reported sweat-based and other non-invasive biosensors either can only monitor a single analyte at a time or lack on-site signal processing circuitry and sensor calibration mechanisms for accurate analysis of the physiological state14–18. Given the complexity of sweat secretion, simultaneous and multiplexed screening of target biomarkers is critical and requires full system integration to ensure the accuracy of measurements. Here we present a mechanically flexible and fully integrated (that is, no external analysis is needed) sensor array for multiplexed in situ perspiration analysis, which simultaneously and selectively measures sweat metabolites (such as glucose and lactate) and electrolytes (such as sodium and potassium ions), as well as the skin temperature (to calibrate the response of the sensors). Our work bridges the technological gap between signal transduction, conditioning (amplification and filtering), processing and wireless transmission in wearable biosensors by merging plastic-based sensors that interface with the skin with silicon integrated circuits consolidated on a flexible circuit board for complex signal processing. This application could not have been realized using either of these technologies alone owing to their respective inherent limitations. The wearable system is used to measure the detailed sweat profile of human subjects engaged in prolonged indoor and outdoor physical activities, and to make a real-time assessment of the physiological state of the subjects. This platform enables a wide range of personalized diagnostic and physiological monitoring applications. PMID:26819044

  8. CalQuo: automated, simultaneous single-cell and population-level quantification of global intracellular Ca2+ responses.

    PubMed

    Fritzsche, Marco; Fernandes, Ricardo A; Colin-York, Huw; Santos, Ana M; Lee, Steven F; Lagerholm, B Christoffer; Davis, Simon J; Eggeling, Christian

    2015-11-13

    Detecting intracellular calcium signaling with fluorescent calcium indicator dyes is often coupled with microscopy techniques to follow the activation state of non-excitable cells, including lymphocytes. However, the analysis of global intracellular calcium responses both at the single-cell level and in large ensembles simultaneously has yet to be automated. Here, we present a new software package, CalQuo (Calcium Quantification), which allows the automated analysis and simultaneous monitoring of global fluorescent calcium reporter-based signaling responses in up to 1000 single cells per experiment, at temporal resolutions of sub-seconds to seconds. CalQuo quantifies the number and fraction of responding cells, the temporal dependence of calcium signaling and provides global and individual calcium-reporter fluorescence intensity profiles. We demonstrate the utility of the new method by comparing the calcium-based signaling responses of genetically manipulated human lymphocytic cell lines.

  9. Simultaneous analysis of fourteen endogenous steroid hormones by liquid chromatography tandem mass spectrometry with atmospheric pressure photoionization

    EPA Science Inventory

    Product Description: To understand how some chemicals affect the endocrine system, controlled lab experiments often monitor how chemicals impact natural steroid hormones in fish. Current methods can target only one or two hormones in a single sample, limiting the information that...

  10. Multiple Reaction Monitoring Mode Based Liquid Chromatography-Mass Spectrometry Method for Simultaneous Quantification of Brassinolide and Other Plant Hormones Involved in Abiotic Stresses.

    PubMed

    Kasote, Deepak M; Ghosh, Ritesh; Chung, Jun Young; Kim, Jonggeun; Bae, Inhwan; Bae, Hanhong

    2016-01-01

    Plant hormones are the key regulators of adaptive stress response. Abiotic stresses such as drought and salt are known to affect the growth and productivity of plants. It is well known that the levels of plant hormones such as zeatin (ZA), abscisic acid (ABA), salicylic acid (SA), jasmonic acid (JA), and brassinolide (BR) fluctuate upon abiotic stress exposure. At present, there is not any single suitable liquid chromatography-mass spectrometry (LC-MS) method for simultaneous analysis of BR and other plant hormones involved in abiotic stresses. In the present study, we developed a simple, sensitive, and rapid method for simultaneous analysis of five major plant hormones, ZA, ABA, JA, SA, and BR, which are directly or indirectly involved in drought and salt stresses. The optimized extraction procedure was simple and easy to use for simultaneous measurement of these plant hormones in Arabidopsis thaliana. The developed method is highly reproducible and can be adapted for simultaneous measurement of changes in plant hormones (ZA, ABA, JA, SA, and BR) in response to abiotic stresses in plants like A. thaliana and tomato.

  11. Comparative analysis of radioecological monitoring dosimeters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sobolev, A.I.; Pol`skii, O.G.; Shanin, O.B.

    1995-03-01

    This paper describes comparative estimates of radiation doses measured by two types of thermoluminescence dosimeters and two types of background radiation radiometers. The dosimetry systems were tested by simultaneously recording background radiation and standard radiation sources at a radioactive waste storage facility. Statistical analysis of the measurement results is summarized. The maximum recorded exposure dose rate for the experiment was 19 microrads per hour. The DTK-2 dosimeter overestimated dose rates by 6 to 43% and the DTU-2 dosimeter underestimated dose rates by 7 to 21%. Both devices are recommended for radioecological monitoring in populated areas. 4 refs., 3 figs., 5more » tabs.« less

  12. Application of thoron interference as a tool for simultaneous measurement of radon and thoron with a pulse ionisation chamber.

    PubMed

    Tripathi, R M; Sumesh, C G; Vinod Kumar, A; Puranik, V D

    2013-07-01

    Pulse ionisation chamber (PIC)-based monitors measuring radioactive gas radon ((222)Rn) without energy discrimination will have interference due to thoron ((220)Rn) present in the atmosphere. A technique has been developed to use this property of interference for simultaneous measurement of radon and thoron gas. These monitors work on the principle of counting of gross alphas emitted from radon and its progeny. A theoretical model has been developed for the variation of thoron sensitivity with respect to the flow rate of gas through the monitor. The thoron sensitivity of the monitor is found to vary with the flow rate of gas through the monitor. Using this sensitivity, the sampling procedure has been developed and verified for simultaneous measurement of radon and thoron. The PIC-measured radon and thoron concentration using this procedure agrees well with those measured by using standard radon and thoron discriminating monitor.

  13. Analysis of oxidative stress biomarkers using a simultaneous competitive/non-competitive micromosaic immunoassay.

    PubMed

    Murphy, Brian M; Dandy, David S; Henry, Charles S

    2009-04-27

    Immunoassays represent a core workhorse methodology for many applications ranging from clinical diagnostics to environmental monitoring. In traditional formats such as the enzyme linked immunosorbent assay (ELISA), analytes are measured singly or in small sets. As more biomarkers are identified for disease states, there is a need to develop methods that can measure multiple markers simultaneously. Immunoaffinity arrays are one such chemistry that can achieve multi-marker screening. Most arrays are performed in either competitive or non-competitive formats, where the former are used predominantly for small molecules and the later for macromolecules. To date, ELISA and immunoaffinity array methods have relied exclusively on one of these formats and not the other. Here an immunoaffinity array method capable of performing simultaneous competitive and non-competitive analysis generated using micromosaic immunoassay techniques is introduced for the analysis of metabolites and proteins. In this report, three markers of oxidative stress were used as a model system. The method described here demonstrates the simultaneous analysis of 3-nitrotyrosine, by indirect competitive immunoassay while the enzymes catalase and superoxide dismutase are analyzed by non-competitive sandwich immunoassay. The method requires less than 1 microL sample and 45 min for completion. Logistic curve fits and LOD (limits of detection) statistical analysis of the binding results are presented and show good agreement with published data for these antibody-antigen systems.

  14. Simultaneous chromatic dispersion, polarization-mode-dispersion and OSNR monitoring at 40Gbit/s.

    PubMed

    Baker-Meflah, Lamia; Thomsen, Benn; Mitchell, John; Bayvel, Polina

    2008-09-29

    A novel method for independent and simultaneous monitoring of chromatic dispersion (CD), first-order PMD and OSNR in 40Gbit/s systems is proposed and demonstrated. This is performed using in-band tone monitoring of 5GHz, optically down-converted to a low intermediate-frequency (IF) of 10kHz. The measurement provides a large monitoring range with good accuracies for CD (4742+/-100ps/nm), differential group delay (DGD) (200+/-4ps) and OSNR (23+/-1dB), independently of the bit-rate. In addition, the use of electro-absorption modulators (EAM) for the simultaneous down-conversion of all channels and the use of low-speed detectors makes it cost effective for multi-channel operation.

  15. Security warning system monitors up to fifteen remote areas simultaneously

    NASA Technical Reports Server (NTRS)

    Fusco, R. C.

    1966-01-01

    Security warning system consisting of 15 television cameras is capable of monitoring several remote or unoccupied areas simultaneously. The system uses a commutator and decommutator, allowing time-multiplexed video transmission. This security system could be used in industrial and retail establishments.

  16. Simulated microsurgery monitoring using intraoperative multimodal surgical microscopy

    NASA Astrophysics Data System (ADS)

    Lee, Donghyun; Lee, Changho; Kim, Sehui; Zhou, Qifa; Kim, Jeehyun; Kim, Chulhong

    2016-03-01

    We have developed an intraoperative multimodal surgical microscopy system that provides simultaneous real-time enlarged surface views and subsurface anatomic information during surgeries by integrating spectral domain optical coherence tomography (SD-OCT), optical-resolution photoacoustic microscopy (OR-PAM), and conventional surgical microscopy. By sharing the same optical path, both OCT and PAM images were simultaneously acquired. Additionally, the custom-made needle-type transducer received the generated PA signals enabling convenient surgical operation without using a water bath. Using a simple augmented device, the OCT and PAM images were projected on the view plane of the surgical microscope. To quantify the performance of our system, we measured spatial resolutions of our system. Then, three microsurgery simulation and analysis were processed: (1) ex vivo needle tracking and monitoring injection of carbon particles in biological tissues, (2) in vivo needle tracking and monitoring injection of carbon particles in tumor-bearing mice, and (3) in vivo guiding of melanoma removal in melanoma-bearing mice. The results indicate that this triple modal system is useful for intraoperative purposes, and can potentially be a vital tool in microsurgeries.

  17. Adduct ion-targeted qualitative and quantitative analysis of polyoxypregnanes by ultra-high pressure liquid chromatography coupled with triple quadrupole mass spectrometry.

    PubMed

    Wu, Xu; Zhu, Lin; Ma, Jiang; Ye, Yang; Lin, Ge

    2017-10-25

    Polyoxypregnane and its glycosides (POPs) are frequently present in plants of Asclepiadaceae family, and have a variety of biological activities. There is a great need to comprehensively profile these phytochemicals and to quantify them for monitoring their contents in the herbs and the biological samples. However, POPs undergo extensive adduct ion formation in ESI-MS, which has posed a challenge for qualitative and quantitative analysis of POPs. In the present study, we took the advantage of such extensive adduct ion formation to investigate the suitability of adduct ion-targeted analysis of POPs. For the qualitative analysis, we firstly demonstrated that the sodium and ammonium adduct ion-targeted product ion scans (PIS) provided adequate MS/MS fragmentations for structural characterization of POPs. Aided with precursor ion (PI) scans, which showed high selectivity and sensitivity and improved peak assignment confidence in conjunction with full scan (FS), the informative adduct ion-targeted PIS enabled rapid POPs profiling. For the quantification, we used formic acid rather than ammonium acetate as an additive in the mobile phase to avoid simultaneous formation of sodium and ammonium adduct ions, and greatly improved reproducibility of MS response of POPs. By monitoring the solely formed sodium adduct ions [M+Na] + , a method for simultaneous quantification of 25 POPs in the dynamic multiple reaction monitoring mode was then developed and validated. Finally, the aforementioned methods were applied to qualitative and quantitative analysis of POPs in the extract of a traditional Chinses medicinal herb, Marsdenia tenacissima (Roxb.) Wight et Arn., and in the plasma obtained from the rats treated with this herb. The results demonstrated that adduct ion formation could be optimized for the qualitative and quantitative analysis of POPs, and our developed PI/FS-PIS scanning and sole [M+Na] + ion monitoring significantly improved the analysis of POPs in both herbal and biological samples. This study also provides implications for the analysis of other compounds which undergo extensive adduct ion formation in ESI-MS. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Simultaneous analysis of aminoglycosides with many other classes of drug residues in bovine tissues by ultrahigh-performance liquid chromatography-tandem mass spectrometry using an ion-pairing reagent added to final extracts

    USDA-ARS?s Scientific Manuscript database

    The way to maximize scope of analysis, sample throughput, and laboratory efficiency in the monitoring of veterinary drug residues in food animals is to determine as many analytes as possible as fast as possible in as few methods as possible. Capital and overhead expenses are also reduced by using f...

  19. Fast online simultaneous monitoring of PMD and chromatic dispersion with reduced polarization dependent gain

    NASA Astrophysics Data System (ADS)

    Ning, G.; Shum, P.; Aditya, S.; Gong, Yandong

    2006-09-01

    We use the expression relating the output state of polarization and PMD vector. Based on this expression we get the power fading including first-order PMD and chromatic dispersion, which is dependent on the angle of precession of output state of polarization around the PMD vector. From the expression for power fading, we get the average power penalty for chromatic dispersion and PMD. We propose a novel and fast PMD and chromatic dispersion monitoring technology. Measured results agree well with theoretical analysis.

  20. Simultaneous sequential monitoring of efficacy and safety led to masking of effects.

    PubMed

    van Eekelen, Rik; de Hoop, Esther; van der Tweel, Ingeborg

    2016-08-01

    Usually, sequential designs for clinical trials are applied on the primary (=efficacy) outcome. In practice, other outcomes (e.g., safety) will also be monitored and influence the decision whether to stop a trial early. Implications of simultaneous monitoring on trial decision making are yet unclear. This study examines what happens to the type I error, power, and required sample sizes when one efficacy outcome and one correlated safety outcome are monitored simultaneously using sequential designs. We conducted a simulation study in the framework of a two-arm parallel clinical trial. Interim analyses on two outcomes were performed independently and simultaneously on the same data sets using four sequential monitoring designs, including O'Brien-Fleming and Triangular Test boundaries. Simulations differed in values for correlations and true effect sizes. When an effect was present in both outcomes, competition was introduced, which decreased power (e.g., from 80% to 60%). Futility boundaries for the efficacy outcome reduced overall type I errors as well as power for the safety outcome. Monitoring two correlated outcomes, given that both are essential for early trial termination, leads to masking of true effects. Careful consideration of scenarios must be taken into account when designing sequential trials. Simulation results can help guide trial design. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. IR spectroscopy analysis of pancreatic lipase-related protein 2 interaction with phospholipids: 3. Monitoring DPPC lipolysis in mixed micelles.

    PubMed

    Mateos-Diaz, Eduardo; Sutto-Ortiz, Priscila; Sahaka, Moulay; Rodriguez, Jorge A; Carrière, Frédéric

    2018-03-01

    Usual methods for the continuous assay of lipolytic enzyme activities are mainly based on the titration of free fatty acids, surface pressure monitoring or spectrophotometry using substrates labeled with specific probes. These approaches only give a partial information on the chemistry of the lipolysis reaction and additional end-point analyses are often required to quantify both residual substrate and lipolysis products. We used transmission infrared (IR) spectroscopy to monitor simultaneously the hydrolysis of phospholipids by guinea pig pancreatic lipase-related protein 2 (GPLRP2) and the release of lipolysis products. The substrate (DPPC, 1,2-Dipalmitoyl phosphatidylcholine) was mixed with sodium taurodeoxycholate (NaTDC) to form mixed micelles in D 2 O buffer at pD 6 and 8. After hydrogen/deuterium exchange, DPPC hydrolysis by GPLRP2 (100nM) was monitored at 35°C in a liquid cell by recording IR spectra and time-course variations in the CO stretching region. These changes were correlated to variations in the concentrations of DPPC, lysophospholipids (lysoPC) and palmitic acid (Pam) using calibration curves established with these compounds individually mixed with NaTDC. We were thus able to quantify each compound and its time-course variations during the phospholipolysis reaction and to estimate the enzyme activity. To validate the IR analysis, variations in residual DPPC, lysoPC and Pam were also quantified by thin-layer chromatography coupled to densitometry and similar hydrolysis profiles were obtained using both methods. IR spectroscopy can therefore be used to monitor the enzymatic hydrolysis of phospholipids and obtain simultaneously chemical and physicochemical information on substrate and all reaction products (H-bonding, hydration, acyl chain mobility). Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Ear-EEG detects ictal and interictal abnormalities in focal and generalized epilepsy - A comparison with scalp EEG monitoring.

    PubMed

    Zibrandtsen, I C; Kidmose, P; Christensen, C B; Kjaer, T W

    2017-12-01

    Ear-EEG is recording of electroencephalography from a small device in the ear. This is the first study to compare ictal and interictal abnormalities recorded with ear-EEG and simultaneous scalp-EEG in an epilepsy monitoring unit. We recorded and compared simultaneous ear-EEG and scalp-EEG from 15 patients with suspected temporal lobe epilepsy. EEGs were compared visually by independent neurophysiologists. Correlation and time-frequency analysis was used to quantify the similarity between ear and scalp electrodes. Spike-averages were used to assess similarity of interictal spikes. There were no differences in sensitivity or specificity for seizure detection. Mean correlation coefficient between ear-EEG and nearest scalp electrode was above 0.6 with a statistically significant decreasing trend with increasing distance away from the ear. Ictal morphology and frequency dynamics can be observed from visual inspection and time-frequency analysis. Spike averages derived from ear-EEG electrodes yield a recognizable spike appearance. Our results suggest that ear-EEG can reliably detect electroencephalographic patterns associated with focal temporal lobe seizures. Interictal spike morphology from sufficiently large temporal spike sources can be sampled using ear-EEG. Ear-EEG is likely to become an important tool in clinical epilepsy monitoring and diagnosis. Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  3. Simultaneous monitoring of static and dynamic intracranial pressure parameters from two separate sensors in patients with cerebral bleeds: comparison of findings.

    PubMed

    Eide, Per Kristian; Holm, Sverre; Sorteberg, Wilhelm

    2012-09-07

    We recently reported that in an experimental setting the zero pressure level of solid intracranial pressure (ICP) sensors can be altered by electrostatics discharges. Changes in the zero pressure level would alter the ICP level (mean ICP); whether spontaneous changes in mean ICP happen in clinical settings is not known. This can be addressed by comparing the ICP parameters level and waveform of simultaneous ICP signals. To this end, we retrieved our recordings in patients with cerebral bleeds wherein the ICP had been recorded simultaneously from two different sensors. During a time period of 10 years, 17 patients with cerebral bleeds were monitored with two ICP sensors simultaneously; sensor 1 was always a solid sensor while Sensor 2 was a solid -, a fluid - or an air-pouch sensor. The simultaneous signals were analyzed with automatic identification of the cardiac induced ICP waves. The output was determined in consecutive 6-s time windows, both with regard to the static parameter mean ICP and the dynamic parameters (mean wave amplitude, MWA, and mean wave rise time, MWRT). Differences in mean ICP, MWA and MWRT between the two sensors were determined. Transfer functions between the sensors were determined to evaluate how sensors reproduce the ICP waveform. Comparing findings in two solid sensors disclosed major differences in mean ICP in 2 of 5 patients (40%), despite marginal differences in MWA, MWRT, and linear phase magnitude and phase. Qualitative assessment of trend plots of mean ICP and MWA revealed shifts and drifts of mean ICP in the clinical setting. The transfer function analysis comparing the solid sensor with either the fluid or air-pouch sensors revealed more variable transfer function magnitude and greater differences in the ICP waveform derived indices. Simultaneous monitoring of ICP using two solid sensors may show marked differences in static ICP but close to identity in dynamic ICP waveforms. This indicates that shifts in ICP baseline pressure (sensor zero level) occur clinically; trend plots of the ICP parameters also confirm this. Solid sensors are superior to fluid - and air pouch sensors when evaluating the dynamic ICP parameters.

  4. Monitoring the Collapse of pH-Sensitive Liposomal Nanocarriers and Environmental pH Simultaneously: A Fluorescence-Based Approach.

    PubMed

    Draffehn, Sören; Kumke, Michael U

    2016-05-02

    Nowadays, the encapsulation of therapeutic compounds in so-called carrier systems is a very smart method to achieve protection as well as an improvement of their temporal and spatial distribution. After the successful transport to the point of care, the delivery has to be released under controlled conditions. To monitor the triggered release from the carrier, we investigated different fluorescent probes regarding their response to the pH-induced collapse of pH-sensitive liposomes (pHSLip), which occurs when the environmental pH falls below a critical value. Depending on the probe, the fluorescence decay time as well as fluorescence anisotropy can be used equally as key parameters for monitoring the collapse. Especially the application of a fluorescein labeled fatty acid (fPA) enabled the monitoring of the pHSLips collapse and the pH of its microenvironment simultaneously without interference. Varying the pH in the range of 3 < pH < 9, anisotropy data revealed the critical pH value at which the collapse of the pHSLips occurs. Complementary methods, e.g., fluorescence correlation spectroscopy and dynamic light scattering, supported the analysis based on the decay time and anisotropy. Additional experiments with varying incubation times yielded information on the kinetics of the liposomal collapse.

  5. Optical non-invasive monitoring of skin blood pulsations

    NASA Astrophysics Data System (ADS)

    Spīgulis, Jānis

    2005-08-01

    Time resolved detection and analysis of the skin backscattered optical signals (remission photoplethysmography or PPG) provide rich information on skin blood volume pulsations and can serve for reliable cardiovascular assessment. The single- and multi-channel PPG concepts are discussed in this work. Simultaneous data flow from several body locations allows one to study the heartbeat pulse wave propagation in real time and evaluate the vascular resistance. Portable single-, dual- and four-channel PPG monitoring devices with special software have been designed for real-time data acquisition and processing. The clinical studies confirmed their potential in the monitoring of heart arrhythmias, drug tests, steady-state cardiovascular assessment, body fitness control, and express diagnostics of the arterial occlusions.

  6. Optical noninvasive monitoring of skin blood pulsations

    NASA Astrophysics Data System (ADS)

    Spigulis, Janis

    2005-04-01

    Time-resolved detection and analysis of skin backscattered optical signals (remission photoplethysmography or PPG) provide rich information on skin blood volume pulsations and can serve for reliable cardiovascular assessment. Single- and multiple-channel PPG concepts are discussed. Simultaneous data flow from several locations on the human body allows us to study heartbeat pulse-wave propagation in real time and to evaluate vascular resistance. Portable single-, dual-, and four-channel PPG monitoring devices with special software have been designed for real-time data acquisition and processing. The prototype devices have been clinically studied, and their potential for monitoring heart arrhythmias, drug-efficiency tests, steady-state cardiovascular assessment, body fitness control, and express diagnostics of the arterial occlusions has been confirmed.

  7. Macro and micro structures in the dorsal anterior cingulate cortex contribute to individual differences in self-monitoring.

    PubMed

    Yang, Junyi; Tian, Xue; Wei, Dongtao; Liu, Huijuan; Zhang, Qinglin; Wang, Kangcheng; Chen, Qunlin; Qiu, Jiang

    2016-06-01

    Individual differences in self-monitoring, which are the capability to adjust behavior to adapt to social situations, influence a wide range of social behaviors. However, understanding of focal differences in brain structures related to individual self-monitoring is minimal, particularly when micro and macro structures are considered simultaneously. The present study investigates the relationship between self-monitoring and brain structure in a relatively large sample of young adults. Voxel-based morphometry (VBM) revealed a significant positive correlation between self-monitoring and gray matter volume in the dorsal cingulate anterior cortex (dACC), dorsal lateral prefrontal cortex (DLPFC), and bilateral ventral striatum (VS). Further analysis revealed a significant negative correlation between self-monitoring and white matter (WM) integrity, as indexed by fractional anisotropy (FA) in the anterior cingulum (ACG) bundle. Moreover, there was a significant positive correlation between self-monitoring and mean radius diffusion (RD). These results shed light on the structural neural basis of variation in self-monitoring.

  8. Adaptive noise cancelling and time-frequency techniques for rail surface defect detection

    NASA Astrophysics Data System (ADS)

    Liang, B.; Iwnicki, S.; Ball, A.; Young, A. E.

    2015-03-01

    Adaptive noise cancelling (ANC) is a technique which is very effective to remove additive noises from the contaminated signals. It has been widely used in the fields of telecommunication, radar and sonar signal processing. However it was seldom used for the surveillance and diagnosis of mechanical systems before late of 1990s. As a promising technique it has gradually been exploited for the purpose of condition monitoring and fault diagnosis. Time-frequency analysis is another useful tool for condition monitoring and fault diagnosis purpose as time-frequency analysis can keep both time and frequency information simultaneously. This paper presents an ANC and time-frequency application for railway wheel flat and rail surface defect detection. The experimental results from a scaled roller test rig show that this approach can significantly reduce unwanted interferences and extract the weak signals from strong background noises. The combination of ANC and time-frequency analysis may provide us one of useful tools for condition monitoring and fault diagnosis of railway vehicles.

  9. Wireless sensing system for bridge condition assessment and health monitoring

    NASA Astrophysics Data System (ADS)

    Gangone, Michael V.; Whelan, Matthew J.; Janoyan, Kerop D.

    2009-03-01

    Discussed in this paper is the deployment of a universal and low-cost dense wireless sensor system for structural monitoring, load rating and condition assessment of bridges. The wireless sensor system developed is designed specifically for diagnostic bridge monitoring, providing independent conditioning for both accelerometers and strain transducers in addition to high-rate wireless data transmission. The system was field deployed on a three span simply supported bridge superstructure, where strain and acceleration measurements were obtained simultaneously and in realtime at critical locations under several loading conditions, providing reliable quantitative information as to the actual performance level of the bridge. Monitoring was also conducted as the bridge was subjected to various controlled damage scenarios on the final day of testing. Select cases of detected damage using strain and modal based analysis are presented.

  10. Hyperglycemia is associated with simultaneous alterations in electrical brain activity in youths with type 1 diabetes mellitus.

    PubMed

    Rachmiel, M; Cohen, M; Heymen, E; Lezinger, M; Inbar, D; Gilat, S; Bistritzer, T; Leshem, G; Kan-Dror, E; Lahat, E; Ekstein, D

    2016-02-01

    To assess the association between hyperglycemia and electrical brain activity in type 1 diabetes mellitus (T1DM). Nine youths with T1DM were monitored simultaneously and continuously by EEG and continuous glucose monitor system, for 40 h. EEG powers of 0.5-80 Hz frequency bands in all the different brain regions were analyzed according to interstitial glucose concentration (IGC) ranges of 4-11 mmol/l, 11-15.5 mmol/l and >15.5 mmol/l. Analysis of variance was used to examine the differences in EEG power of each frequency band between the subgroups of IGC. Analysis was performed separately during wakefulness and sleep, controlling for age, gender and HbA1c. Mean IGC was 11.49 ± 5.26 mmol/l in 1253 combined measurements. IGC>15.5 mmol/l compared to 4-11 mmol/l was associated during wakefulness with increased EEG power of low frequencies and with decreased EEG power of high frequencies. During sleep, it was associated with increased EEG power of low frequencies in all brain areas and of high frequencies in frontal and central areas. Asymptomatic transient hyperglycemia in youth with T1DM is associated with simultaneous alterations in electrical brain activity during wakefulness and sleep. The clinical implications of immediate electrical brain alterations under hyperglycemia need to be studied and may lead to adaptations of management. Copyright © 2015. Published by Elsevier Ireland Ltd.

  11. Simultaneous monitoring of independent gene expression patterns in two types of cocultured fibroblasts with different color-emitting luciferases

    PubMed Central

    Noguchi, Takako; Ikeda, Masaaki; Ohmiya, Yoshihiro; Nakajima, Yoshihiro

    2008-01-01

    Background Luciferase assay systems enable the real-time monitoring of gene expression in living cells. We have developed a dual-color luciferase assay system in which the expression of multiple genes can be tracked simultaneously using green- and red-emitting beetle luciferases. We have applied the system to monitoring independent gene expressions in two types of cocultured fibroblasts in real time. Results Two Rat-1 cell lines were established that stably express either green- or red-emitting luciferases under the control of the mBmal1 promoter, a canonical clock gene. We cocultured these cell lines, and gene expression profiles in both were monitored simultaneously. The circadian rhythms of these cell lines are independent, oscillating following their intrinsic circadian phases, even when cocultured. Furthermore, the independent rhythms were synchronized by medium change as an external stimulus. Conclusion Using this system, we successfully monitored independent gene expression patterns in two lines of cocultured fibroblasts. PMID:18416852

  12. Innovative In-Situ Remediation of Contaminated Sediments for Simultaneous Control of Contamination and Erosion. Part 1

    DTIC Science & Technology

    2010-12-27

    Erosion Rates and Critical Shear Stress ......................... 45 Erosion Rate Ratio Analysis...inductively coupled plasma – mass spectrometry Kd – partition coefficient Meq – milliequivalents MNR – monitored natural recovery SRNL-STI-2010...186 Figure 82. Critical Shear Stress Comparison among Biopolymer Materials at 2, 10, and 175 Days. Each value is an average of

  13. Innovative In-Situ Remediation of Contaminated Sediments for Simultaneous Control of Contamination and Erosion. Part 1

    DTIC Science & Technology

    2011-08-01

    Measurements of Sediment Erosion Rates and Critical Shear Stress ......................... 45 Erosion Rate Ratio Analysis...chromatography ICP-MS – inductively coupled plasma – mass spectrometry Kd – partition coefficient Meq – milliequivalents MNR – monitored natural...186 Figure 82. Critical Shear Stress Comparison among Biopolymer Materials at 2, 10, and 175 Days. Each

  14. Examining the Relationship between Heart Rate and Problem Behavior: A Case Study of Severe Skin Picking in Prader-Willi Syndrome

    ERIC Educational Resources Information Center

    Hall, Scott S.; Hammond, Jennifer L.; Hustyi, Kristin M.

    2013-01-01

    Few studies have examined the relationship between heart rate and self-injurious behavior (SIB) shown by individuals with IDD (intellectual and developmental disabilities). In this single-case study, we simultaneously monitored heart rate and activity levels during a functional analysis of severe skin picking behavior exhibited by a young man with…

  15. Assessment of the clinical efficacy of the heart spectrum blood pressure monitor for diagnosis of atrial fibrillation: An unblinded clinical trial.

    PubMed

    Kao, Wei-Fong; Hou, Sen-Kuang; Huang, Chun-Yao; Chao, Chun-Chieh; Cheng, Chung-Chih; Chen, Yi-Jung

    2018-01-01

    Atrial fibrillation (AF) is the most common arrhythmia. The most common diagnostic method, 12-lead electrocardiogram (ECG), can record episodes of arrhythmia from which the type and severity can be determined. The Heart Spectrum Blood Pressure Monitor (P2; OSTAR Meditech Corp., New Taipei City, Taiwan) is used to measure cardiovascular pressure change with fast Fourier transform (FFT) analysis to obtain heart rate frequency variability and accurate blood pressure data. We compared the diagnostic efficacy of the Heart Spectrum Blood Pressure Monitor to a 12-lead ECG (gold standard) for patients with AF. Three measurement methods were used in this study to analyze the heart index and compare the results with simultaneous 12-lead ECG: blood pressure; mean arterial pressure, which was calculated from individual blood pressure as a constant pressure; and a constant pressure of 60 mmHg. The physician used a 12-lead ECG and the Heart Spectrum Blood Pressure Monitor simultaneously. The Heart Spectrum Blood Pressure Monitor used FFT analysis to diagnose AF, and the findings were compared to the 12-lead ECG readings. This unblinded clinical trial was conducted in the emergency department of Taipei Medical University Hospital. Twenty-nine subjects with AF and 33 without AF aged 25 to 97 y (mean, 63.5 y) were included. Subjects who were exposed to high-frequency surgical equipment during testing, those with cardiac pacemakers or implantable defibrillators, and pregnant women were excluded. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were 97%, 97%, 97%, and 97%, respectively, for method 1; 90%, 100%, 100%, and 91%, respectively, for method 2; and 100%, 94%, 94%, and 100%, respectively, for method 3. The sensitivity, specificity, PPV, and NPV for both methods ranged between 90% and 100%, indicating that the Heart Spectrum Blood Pressure Monitor can be effectively applied for AF detection.

  16. Assessment of the clinical efficacy of the heart spectrum blood pressure monitor for diagnosis of atrial fibrillation: An unblinded clinical trial

    PubMed Central

    Kao, Wei-Fong; Hou, Sen-Kuang; Huang, Chun-Yao; Cheng, Chung-Chih; Chen, Yi-Jung

    2018-01-01

    Atrial fibrillation (AF) is the most common arrhythmia. The most common diagnostic method, 12-lead electrocardiogram (ECG), can record episodes of arrhythmia from which the type and severity can be determined. The Heart Spectrum Blood Pressure Monitor (P2; OSTAR Meditech Corp., New Taipei City, Taiwan) is used to measure cardiovascular pressure change with fast Fourier transform (FFT) analysis to obtain heart rate frequency variability and accurate blood pressure data. We compared the diagnostic efficacy of the Heart Spectrum Blood Pressure Monitor to a 12-lead ECG (gold standard) for patients with AF. Three measurement methods were used in this study to analyze the heart index and compare the results with simultaneous 12-lead ECG: blood pressure; mean arterial pressure, which was calculated from individual blood pressure as a constant pressure; and a constant pressure of 60 mmHg. The physician used a 12-lead ECG and the Heart Spectrum Blood Pressure Monitor simultaneously. The Heart Spectrum Blood Pressure Monitor used FFT analysis to diagnose AF, and the findings were compared to the 12-lead ECG readings. This unblinded clinical trial was conducted in the emergency department of Taipei Medical University Hospital. Twenty-nine subjects with AF and 33 without AF aged 25 to 97 y (mean, 63.5 y) were included. Subjects who were exposed to high-frequency surgical equipment during testing, those with cardiac pacemakers or implantable defibrillators, and pregnant women were excluded. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were 97%, 97%, 97%, and 97%, respectively, for method 1; 90%, 100%, 100%, and 91%, respectively, for method 2; and 100%, 94%, 94%, and 100%, respectively, for method 3. The sensitivity, specificity, PPV, and NPV for both methods ranged between 90% and 100%, indicating that the Heart Spectrum Blood Pressure Monitor can be effectively applied for AF detection. PMID:29902218

  17. A new environment for multiple spacecraft power subsystem mission operations

    NASA Technical Reports Server (NTRS)

    Bahrami, K. A.

    1990-01-01

    The engineering analysis subsystem environment (EASE) is being developed to enable fewer controllers to monitor and control power and other spacecraft engineering subsystems. The EASE prototype has been developed to support simultaneous real-time monitoring of several spacecraft engineering subsystems. It is being designed to assist with offline analysis of telemetry data to determine trends, and to help formulate uplink commands to the spacecraft. An early version of the EASE prototype has been installed in the JPL Space Flight Operations Facility for online testing. The EASE prototype is installed in the Galileo Mission Support Area. The underlying concept, development, and testing of the EASE prototype and how it will aid in the ground operations of spacecraft power subsystems are discussed.

  18. Combined multi-distance frequency domain and diffuse correlation spectroscopy system with simultaneous data acquisition and real-time analysis.

    PubMed

    Carp, Stefan A; Farzam, Parisa; Redes, Norin; Hueber, Dennis M; Franceschini, Maria Angela

    2017-09-01

    Frequency domain near infrared spectroscopy (FD-NIRS) and diffuse correlation spectroscopy (DCS) have emerged as synergistic techniques for the non-invasive assessment of tissue health. Combining FD-NIRS oximetry with DCS measures of blood flow, the tissue oxygen metabolic rate can be quantified, a parameter more closely linked to underlying physiology and pathology than either NIRS or DCS estimates alone. Here we describe the first commercially available integrated instrument, called the "MetaOx", designed to enable simultaneous FD-NIRS and DCS measurements at rates of 10 + Hz, and offering real-time data evaluation. We show simultaneously acquired characterization data demonstrating performance equivalent to individual devices and sample in vivo measurements of pulsation resolved blood flow, forearm occlusion hemodynamic changes and muscle oxygen metabolic rate monitoring during stationary bike exercise.

  19. Combined multi-distance frequency domain and diffuse correlation spectroscopy system with simultaneous data acquisition and real-time analysis

    PubMed Central

    Carp, Stefan A.; Farzam, Parisa; Redes, Norin; Hueber, Dennis M.; Franceschini, Maria Angela

    2017-01-01

    Frequency domain near infrared spectroscopy (FD-NIRS) and diffuse correlation spectroscopy (DCS) have emerged as synergistic techniques for the non-invasive assessment of tissue health. Combining FD-NIRS oximetry with DCS measures of blood flow, the tissue oxygen metabolic rate can be quantified, a parameter more closely linked to underlying physiology and pathology than either NIRS or DCS estimates alone. Here we describe the first commercially available integrated instrument, called the “MetaOx”, designed to enable simultaneous FD-NIRS and DCS measurements at rates of 10 + Hz, and offering real-time data evaluation. We show simultaneously acquired characterization data demonstrating performance equivalent to individual devices and sample in vivo measurements of pulsation resolved blood flow, forearm occlusion hemodynamic changes and muscle oxygen metabolic rate monitoring during stationary bike exercise. PMID:29026684

  20. Real time monitoring of rat liver energy state during ischemia.

    PubMed

    Barbiro, E; Zurovsky, Y; Mayevsky, A

    1998-11-01

    Hepatic failure is one of the major problems developed during the posttransplantation period. A possible cause of hepatic failure is the prolonged ischemia induced during the implantation procedure. Hepatic ischemia leads to a reduction in oxygen supply, ATP level decline, liver metabolism impairment, and finally organ failure. The purpose of this study was to estimate the functional state of the liver by monitoring liver blood flow and the mitochondrial NADH redox state simultaneously and continuously during in situ liver ischemia followed by reperfusion. Measurements were performed using the multiprobe developed in our laboratory consisting of fibers for the measurement of relative liver blood flow (laser Doppler flowmetry) and mitochondrial redox state (NADH fluorescence). The experimental procedure included the temporary interruption of blood flow to the liver using three types of ischemia, hepatic artery occlusion, portal vein occlusion, and simultaneous occlusion of hepatic artery and portal vein, followed by a reperfusion period. These preliminary experiments showed a significant decrease in liver blood flow, following the three types of liver ischemia, and a significant increase in NADH levels. The probe used in this study incorporates the advantage of monitoring NADH and liver blood flow simultaneously and continuously from the same area on the surface of the liver. Since each of these two parameters is not calibrated in absolute units, the simultaneous monitoring decreases possible artifacts. Also, it will allow us to determine of the coupling between tissue blood flow and oxidative phosphorylation. It is believed that the measurements of respiratory chain dysfunction might predict organ viability in clinical organ transplantation situations. Using this probe may also help to decrease the variability in liver blood flow monitoring since liver blood flow monitoring is supported simultaneously with the mitochondrial redox state, which supplies the information on liver metabolic and functional state. Copyright 1998 Academic Press.

  1. Clinical Validation of Simultaneous Analysis of Tacrolimus, Cyclosporine A, and Creatinine in Dried Blood Spots in Kidney Transplant Patients.

    PubMed

    Veenhof, Herman; Koster, Remco A; Alffenaar, Jan-Willem C; Berger, Stefan P; Bakker, Stephan J L; Touw, Daan J

    2017-07-01

    Monitoring of creatinine and immunosuppressive drug concentrations, such as tacrolimus (TaC) and cyclosporin A (CsA), is important in the outpatient follow-up of kidney transplant recipients. Monitoring by dried blood spot (DBS) provides patients the opportunity to sample a drop of blood from a fingerprick at home, which can be sent to the laboratory by mail. We performed a clinical validation in which we compared measurements from whole-blood samples obtained by venapuncture with measurements from DBS samples simultaneously obtained by fingerprick. After exclusion of 10 DBS for poor quality, and 2 for other reasons, 199, 104, and 58 samples from a total of 172 patients were available for validation of creatinine, TaC and CsA, respectively. Validation was performed by means of Passing & Bablok regression, and bias was assessed by Bland-Altman analysis. For creatinine, we found y = 0.73x - 1.55 (95% confidence interval [95% CI] slope, 0.71-0.76), giving the conversion formula: (creatinine plasma concentration in μmol/L) = (creatinine concentration in DBS in μmol/L)/0.73, with a nonclinically relevant bias of -2.1 μmol/L (95% CI, -3.7 to -0.5 μmol/L). For TaC, we found y = 1.00x - 0.23 (95% CI slope, 0.91-1.08), with a nonclinically relevant bias of -0.28 μg/L (95% CI, -0.45 to -0.12 μg/L). For CsA, we found y = 0.99x - 1.86 (95% CI slope, 0.91-1.08) and no significant bias. Therefore, for neither TaC nor CsA, a conversion formula is required. DBS sampling for the simultaneous analysis of immunosuppressants and creatinine can replace conventional venous sampling in daily routine.

  2. Damage source identification of reinforced concrete structure using acoustic emission technique.

    PubMed

    Panjsetooni, Alireza; Bunnori, Norazura Muhamad; Vakili, Amir Hossein

    2013-01-01

    Acoustic emission (AE) technique is one of the nondestructive evaluation (NDE) techniques that have been considered as the prime candidate for structural health and damage monitoring in loaded structures. This technique was employed for investigation process of damage in reinforced concrete (RC) frame specimens. A number of reinforced concrete RC frames were tested under loading cycle and were simultaneously monitored using AE. The AE test data were analyzed using the AE source location analysis method. The results showed that AE technique is suitable to identify the sources location of damage in RC structures.

  3. Damage Source Identification of Reinforced Concrete Structure Using Acoustic Emission Technique

    PubMed Central

    Panjsetooni, Alireza; Bunnori, Norazura Muhamad; Vakili, Amir Hossein

    2013-01-01

    Acoustic emission (AE) technique is one of the nondestructive evaluation (NDE) techniques that have been considered as the prime candidate for structural health and damage monitoring in loaded structures. This technique was employed for investigation process of damage in reinforced concrete (RC) frame specimens. A number of reinforced concrete RC frames were tested under loading cycle and were simultaneously monitored using AE. The AE test data were analyzed using the AE source location analysis method. The results showed that AE technique is suitable to identify the sources location of damage in RC structures. PMID:23997681

  4. Accuracy of pulse oximeters in estimating heart rate at rest and during exercise.

    PubMed Central

    Iyriboz, Y; Powers, S; Morrow, J; Ayers, D; Landry, G

    1991-01-01

    Pulse oximeters are being widely used for non-invasive, simultaneous assessment of haemoglobin oxygen saturation. They are reliable, accurate, relatively inexpensive and portable. Pulse oximeters are often used for estimating heart rate at rest and during exercise. However, at present the data available to validate their use as heart rate monitors are not sufficient. We evaluated the accuracy of two oximeters (Radiometer, ear and finger probe; Ohmeda 3700, ear probe) in monitoring heart rate during incremental exercise by comparing the pulse oximeters with simultaneous ECG readings. Data were collected on eight men (713 heart rate readings) during graded cycle ergometer and treadmill exercise to volitional fatigue. Analysis by linear regression revealed that general oximeter readings significantly correlated with those of ECG (r = 0.91, P less than 0.0001). However, comparison of heart rate at each level of work showed that oximeter readings significantly (P less than 0.05) under-estimated rates above 155 beats/min. These results indicate that the use of pulse oximeters as heart rate monitors during strenuous exercise is questionable. This inaccuracy may well originate from the instability of the probes, sweating, other artefacts during exercise, and measurement of different components in the cardiovascular cycle. PMID:1777787

  5. Medical applications of shortwave FM radar: remote monitoring of cardiac and respiratory motion.

    PubMed

    Mostov, K; Liptsen, E; Boutchko, R

    2010-03-01

    This article introduces the use of low power continuous wave frequency modulated radar for medical applications, specifically for remote monitoring of vital signs in patients. Gigahertz frequency radar measures the electromagnetic wave signal reflected from the surface of a human body and from tissue boundaries. Time series analysis of the measured signal provides simultaneous information on range, size, and reflective properties of multiple targets in the field of view of the radar. This information is used to extract the respiratory and cardiac rates of the patient in real time. The results from several preliminary human subject experiments are provided. The heart and respiration rate frequencies extracted from the radar signal match those measured independently for all the experiments, including a case when additional targets are simultaneously resolved in the field of view and a case when only the patient's extremity is visible to the radar antennas. Micropower continuous wave FM radar is a reliable, robust, inexpensive, and harmless tool for real-time monitoring of the cardiac and respiratory rates. Additionally, it opens a range of new and exciting opportunities in diagnostic and critical care medicine. Differences between the presented approach and other types of radars used for biomedical applications are discussed.

  6. Simultaneous Speciation Analysis of Arsenic, Chromium, and Selenium in the Bioaccessible Fraction for Realistic Risk Assessment of Food Safety.

    PubMed

    Sadiq, Nausheen W; Beauchemin, Diane

    2017-12-19

    A simple and fast method was developed for risk assessment of As, Cr, and Se in food, which is demonstrated here using three cooked and uncooked rice samples (basmati as well as organic white and brown rice). The bioaccessible fraction was first determined through online leaching of rice minicolumns (maintained at 37 °C) sequentially with artificial saliva, gastric juice, and intestinal juice while continuously monitoring potentially toxic elements (As, Cr, and Se) by inductively coupled plasma mass spectrometry (ICPMS). Then, a new ion chromatography method with online detection by ICPMS was developed for the simultaneous speciation analysis of As, Cr, and Se in the bioaccessible fraction to determine the portion of these elements that was actually toxic. Using gradient elution, four As species [As(III), As(V), monomethylarsonic acid, and dimethylarsinic acid], two Cr species [Cr(III) and Cr(VI)], and two Se species [Se(IV) and Se(VI)] were separated within 12 min. The simultaneous speciation analysis of As, Cr, and Se revealed that the simple act of cooking can convert all of the carcinogenic Cr(VI) to the safer Cr(III).

  7. Using Mobile Monitoring to Assess Spatial Variability in Urban Air Pollution Levels: Opportunities and Challenges (Invited)

    NASA Astrophysics Data System (ADS)

    Larson, T.

    2010-12-01

    Measuring air pollution concentrations from a moving platform is not a new idea. Historically, however, most information on the spatial variability of air pollutants have been derived from fixed site networks operating simultaneously over space. While this approach has obvious advantages from a regulatory perspective, with the increasing need to understand ever finer scales of spatial variability in urban pollution levels, the use of mobile monitoring to supplement fixed site networks has received increasing attention. Here we present examples of the use of this approach: 1) to assess existing fixed-site fine particle networks in Seattle, WA, including the establishment of new fixed-site monitoring locations; 2) to assess the effectiveness of a regulatory intervention, a wood stove burning ban, on the reduction of fine particle levels in the greater Puget Sound region; and 3) to assess spatial variability of both wood smoke and mobile source impacts in both Vancouver, B.C. and Tacoma, WA. Deducing spatial information from the inherently spatio-temporal measurements taken from a mobile platform is an area that deserves further attention. We discuss the use of “fuzzy” points to address the fine-scale spatio-temporal variability in the concentration of mobile source pollutants, specifically to deduce the broader distribution and sources of fine particle soot in the summer in Vancouver, B.C. We also discuss the use of principal component analysis to assess the spatial variability in multivariate, source-related features deduced from simultaneous measurements of light scattering, light absorption and particle-bound PAHs in Tacoma, WA. With increasing miniaturization and decreasing power requirements of air monitoring instruments, the number of simultaneous measurements that can easily be made from a mobile platform is rapidly increasing. Hopefully the methods used to design mobile monitoring experiments for differing purposes, and the methods used to interpret those measurements will keep pace.

  8. Simultaneous monitoring technique for ASE and MPI noises in distributed Raman Amplified Systems.

    PubMed

    Choi, H Y; Jun, S B; Shin, S K; Chung, Y C

    2007-07-09

    We develop a new technique for simultaneously monitoring the amplified spontaneous emission (ASE) and multi-path interference (MPI) noises in distributed Raman amplified (DRA) systems. This technique utilizes the facts that the degree-of polarization (DOP) of the MPI noise is 1/9, while the ASE noise is unpolarized. The results show that the proposed technique can accurately monitor both of these noises regardless of the bit rates, modulation formats, and optical signal-to-noise ratio (OSNR) levels of the signals.

  9. Analyzing near infrared scattering from human skin to monitor changes in hematocrit

    NASA Astrophysics Data System (ADS)

    Chaiken, Joseph; Deng, Bin; Goodisman, Jerry; Shaheen, George; Bussjager, R. J.

    2012-01-01

    The leading preventable cause of death, world-wide, civilian or military, for all people between the ages of 18-45 is undetected internal hemorrhage. Autonomic compensation mechanisms mask changes such as e.g. hematocrit fluctuations that could give early warning if only they could be monitored continuously with reasonable degrees of precision and relative accuracy. Probing tissue with near infrared radiation (NIR) simultaneously produces remitted fluorescence and Raman scattering (IE) plus Rayleigh/Mie light scattering (EE) that noninvasively give chemical and physical information about the materials and objects within. We model tissue as a three-phase system: plasma and red blood cell (RBC) phases that are mobile and a static tissue phase. In vivo, any volume of tissue naturally experiences spatial and temporal fluctuations of blood plasma and RBC content. Plasma and RBC fractions may be discriminated from each other on the basis of their physical, chemical and optical properties. Thus IE and EE from NIR probing yield information about these fractions. Assuming there is no void volume in viable tissue, or that void volume is constant, changes in plasma and RBC volume fractions may be calculated from simultaneous measurements of the two observables, EE and IE. In a previously published analysis we showed the underlying phenomenology but did not provide an algorithm for calculating volume fractions from experimental data. Here we present a simple analysis that allows continuous monitoring of fluid fraction and hematocrit (Hct) changes by measuring IE and EE, and apply it to some experimental in vivo measurements.

  10. Multiplex Liquid Chromatography-Tandem Mass Spectrometry Assay for Simultaneous Therapeutic Drug Monitoring of Ribavirin, Boceprevir, and Telaprevir

    PubMed Central

    Aouri, Manel; Moradpour, Darius; Cavassini, Matthias; Mercier, Thomas; Buclin, Thierry; Csajka, Chantal; Telenti, Amalio; Rauch, Andri

    2013-01-01

    New directly acting antivirals (DAAs) that inhibit hepatitis C virus (HCV) replication are increasingly used for the treatment of chronic hepatitis C. A marked pharmacokinetic variability and a high potential for drug-drug interactions between DAAs and numerous drug classes have been identified. In addition, ribavirin (RBV), commonly associated with hemolytic anemia, often requires dose adjustment, advocating for therapeutic drug monitoring (TDM) in patients under combined antiviral therapy. However, an assay for the simultaneous analysis of RBV and DAAs constitutes an analytical challenge because of the large differences in polarity among these drugs, ranging from hydrophilic (RBV) to highly lipophilic (telaprevir [TVR]). Moreover, TVR is characterized by erratic behavior on standard octadecyl-based reversed-phase column chromatography and must be separated from VRT-127394, its inactive C-21 epimer metabolite. We have developed a convenient assay employing simple plasma protein precipitation, followed by high-performance liquid chromatography coupled to tandem mass spectrometry (HPLC-MS/MS) for the simultaneous determination of levels of RBV, boceprevir, and TVR, as well as its metabolite VRT-127394, in plasma. This new, simple, rapid, and robust HPLC-MS/MS assay offers an efficient method of real-time TDM aimed at maximizing efficacy while minimizing the toxicity of antiviral therapy. PMID:23629707

  11. Monitoring Telluric Absorption with CAMAL

    NASA Astrophysics Data System (ADS)

    Baker, Ashley D.; Blake, Cullen H.; Sliski, David H.

    2017-08-01

    Ground-based astronomical observations may be limited by telluric water vapor absorption, which is highly variable in time and significantly complicates both spectroscopy and photometry in the near-infrared (NIR). To achieve the sensitivity required to detect Earth-sized exoplanets in the NIR, simultaneous monitoring of precipitable water vapor (PWV) becomes necessary to mitigate the impact of variable telluric lines on radial velocity measurements and transit light curves. To address this issue, we present the Camera for the Automatic Monitoring of Atmospheric Lines (CAMAL), a stand-alone, inexpensive six-inch aperture telescope dedicated to measuring PWV at the Fred Lawrence Whipple Observatory on Mount Hopkins. CAMAL utilizes three narrowband NIR filters to trace the amount of atmospheric water vapor affecting simultaneous observations with the MINiature Exoplanet Radial Velocity Array (MINERVA) and MINERVA-Red telescopes. Here, we present the current design of CAMAL, discuss our data analysis methods, and show results from 11 nights of PWV measurements taken with CAMAL. For seven nights of data we have independent PWV measurements extracted from high-resolution stellar spectra taken with the Tillinghast Reflector Echelle Spectrometer (TRES) also located on Mount Hopkins. We use the TRES spectra to calibrate the CAMAL absolute PWV scale. Comparisons between CAMAL and TRES PWV estimates show excellent agreement, matching to within 1 mm over a 10 mm range in PWV. Analysis of CAMAL’s photometric precision propagates to PWV measurements precise to better than 0.5 mm in dry (PWV < 4 mm) conditions. We also find that CAMAL-derived PWVs are highly correlated with those from a GPS-based water vapor monitor located approximately 90 km away at Kitt Peak National Observatory, with a root mean square PWV difference of 0.8 mm.

  12. Simultaneous measurement of multiple radiation-induced protein expression profiles using the Luminex(TM) system

    NASA Technical Reports Server (NTRS)

    Desai, N.; Wu, H.; George, K.; Gonda, S. R.; Cucinotta, F. A.; Cucniotta, F. A. (Principal Investigator)

    2004-01-01

    Space flight results in the exposure of astronauts to a mixed field of radiation composed of energetic particles of varying energies, and biological indicators of space radiation exposure provides a better understanding of the associated long-term health risks. Current methods of biodosimetry have employed the use of cytogenetic analysis for biodosimetry, and more recently the advent of technological progression has led to advanced research in the use of genomic and proteomic expression profiling to simultaneously assess biomarkers of radiation exposure. We describe here the technical advantages of the Luminex(TM) 100 system relative to traditional methods and its potential as a tool to simultaneously profile multiple proteins induced by ionizing radiation. The development of such a bioassay would provide more relevant post-translational dynamics of stress response and will impart important implications in the advancement of space and other radiation contact monitoring. c2004 COSPAR. Published by Elsevier Ltd. All rights reserved.

  13. Simultaneous monitoring of static and dynamic intracranial pressure parameters from two separate sensors in patients with cerebral bleeds: comparison of findings

    PubMed Central

    2012-01-01

    Background We recently reported that in an experimental setting the zero pressure level of solid intracranial pressure (ICP) sensors can be altered by electrostatics discharges. Changes in the zero pressure level would alter the ICP level (mean ICP); whether spontaneous changes in mean ICP happen in clinical settings is not known. This can be addressed by comparing the ICP parameters level and waveform of simultaneous ICP signals. To this end, we retrieved our recordings in patients with cerebral bleeds wherein the ICP had been recorded simultaneously from two different sensors. Materials and Methods: During a time period of 10 years, 17 patients with cerebral bleeds were monitored with two ICP sensors simultaneously; sensor 1 was always a solid sensor while Sensor 2 was a solid -, a fluid - or an air-pouch sensor. The simultaneous signals were analyzed with automatic identification of the cardiac induced ICP waves. The output was determined in consecutive 6-s time windows, both with regard to the static parameter mean ICP and the dynamic parameters (mean wave amplitude, MWA, and mean wave rise time, MWRT). Differences in mean ICP, MWA and MWRT between the two sensors were determined. Transfer functions between the sensors were determined to evaluate how sensors reproduce the ICP waveform. Results Comparing findings in two solid sensors disclosed major differences in mean ICP in 2 of 5 patients (40%), despite marginal differences in MWA, MWRT, and linear phase magnitude and phase. Qualitative assessment of trend plots of mean ICP and MWA revealed shifts and drifts of mean ICP in the clinical setting. The transfer function analysis comparing the solid sensor with either the fluid or air-pouch sensors revealed more variable transfer function magnitude and greater differences in the ICP waveform derived indices. Conclusions Simultaneous monitoring of ICP using two solid sensors may show marked differences in static ICP but close to identity in dynamic ICP waveforms. This indicates that shifts in ICP baseline pressure (sensor zero level) occur clinically; trend plots of the ICP parameters also confirm this. Solid sensors are superior to fluid – and air pouch sensors when evaluating the dynamic ICP parameters. PMID:22958653

  14. Ground subsidence information as a valuable layer in GIS analysis

    NASA Astrophysics Data System (ADS)

    Murdzek, Radosław; Malik, Hubert; Leśniak, Andrzej

    2018-04-01

    Among the technologies used to improve functioning of local governments the geographic information systems (GIS) are widely used. GIS tools allow to simultaneously integrate spatial data resources, analyse them, process and use them to make strategic decisions. Nowadays GIS analysis is widely used in spatial planning or environmental protection. In these applications a number of spatial information are utilized, but rarely it is an information about environmental hazards. This paper includes information about ground subsidence that occurred in USCB mining area into GIS analysis. Monitoring of this phenomenon can be carried out using the radar differential interferometry (DInSAR) method.

  15. Optical multichannel monitoring of skin blood pulsations for cardiovascular assessment

    NASA Astrophysics Data System (ADS)

    Spigulis, Janis; Erts, Renars; Ozols, Maris

    2004-07-01

    Time resolved detection and analysis of the skin back-scattered optical signals (reflection photoplethysmography or PPG) provide rich information on skin blood volume pulsations and can serve for cardiovascular assessment. The multichannel PPG concept has been developed and clinically verified in this work. Simultaneous data flow from several body locations allows to study the heartbeat pulse wave propagation in real time and to evaluate the vascular resistance. Portable two- and four-channel PPG monitoring devices and special software have been designed for real-time data acquisition and processing. The multi-channel devices were successfully applied for cardiovascular fitness tests and for early detection of arterial occlusions.

  16. Live single cell functional phenotyping in droplet nano-liter reactors

    NASA Astrophysics Data System (ADS)

    Konry, Tania; Golberg, Alexander; Yarmush, Martin

    2013-11-01

    While single cell heterogeneity is present in all biological systems, most studies cannot address it due to technical limitations. Here we describe a nano-liter droplet microfluidic-based approach for stimulation and monitoring of surfaceand secreted markers of live single immune dendritic cells (DCs) as well as monitoring the live T cell/DC interaction. This nano-liter in vivo simulating microenvironment allows delivering various stimuli reagents to each cell and appropriate gas exchanges which are necessary to ensure functionality and viability of encapsulated cells. Labeling bioassay and microsphere sensors were integrated into nano-liter reaction volume of the droplet to monitor live single cell surface markers and secretion analysis in the time-dependent fashion. Thus live cell stimulation, secretion and surface monitoring can be obtained simultaneously in distinct microenvironment, which previously was possible using complicated and multi-step in vitro and in vivo live-cell microscopy, together with immunological studies of the outcome secretion of cellular function.

  17. High-Resolution, Non-Invasive Imaging of Upper Vocal Tract Articulators Compatible with Human Brain Recordings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bouchard, Kristofer E.; Conant, David F.; Anumanchipalli, Gopala K.

    A complete neurobiological understanding of speech motor control requires determination of the relationship between simultaneously recorded neural activity and the kinematics of the lips, jaw, tongue, and larynx. Many speech articulators are internal to the vocal tract, and therefore simultaneously tracking the kinematics of all articulators is nontrivial-especially in the context of human electrophysiology recordings. Here, we describe a noninvasive, multi-modal imaging system to monitor vocal tract kinematics, demonstrate this system in six speakers during production of nine American English vowels, and provide new analysis of such data. Classification and regression analysis revealed considerable variability in the articulator-to-acoustic relationship acrossmore » speakers. Non-negative matrix factorization extracted basis sets capturing vocal tract shapes allowing for higher vowel classification accuracy than traditional methods. Statistical speech synthesis generated speech from vocal tract measurements, and we demonstrate perceptual identification. We demonstrate the capacity to predict lip kinematics from ventral sensorimotor cortical activity. These results demonstrate a multi-modal system to non-invasively monitor articulator kinematics during speech production, describe novel analytic methods for relating kinematic data to speech acoustics, and provide the first decoding of speech kinematics from electrocorticography. These advances will be critical for understanding the cortical basis of speech production and the creation of vocal prosthetics.« less

  18. High-Resolution, Non-Invasive Imaging of Upper Vocal Tract Articulators Compatible with Human Brain Recordings

    PubMed Central

    Anumanchipalli, Gopala K.; Dichter, Benjamin; Chaisanguanthum, Kris S.; Johnson, Keith; Chang, Edward F.

    2016-01-01

    A complete neurobiological understanding of speech motor control requires determination of the relationship between simultaneously recorded neural activity and the kinematics of the lips, jaw, tongue, and larynx. Many speech articulators are internal to the vocal tract, and therefore simultaneously tracking the kinematics of all articulators is nontrivial—especially in the context of human electrophysiology recordings. Here, we describe a noninvasive, multi-modal imaging system to monitor vocal tract kinematics, demonstrate this system in six speakers during production of nine American English vowels, and provide new analysis of such data. Classification and regression analysis revealed considerable variability in the articulator-to-acoustic relationship across speakers. Non-negative matrix factorization extracted basis sets capturing vocal tract shapes allowing for higher vowel classification accuracy than traditional methods. Statistical speech synthesis generated speech from vocal tract measurements, and we demonstrate perceptual identification. We demonstrate the capacity to predict lip kinematics from ventral sensorimotor cortical activity. These results demonstrate a multi-modal system to non-invasively monitor articulator kinematics during speech production, describe novel analytic methods for relating kinematic data to speech acoustics, and provide the first decoding of speech kinematics from electrocorticography. These advances will be critical for understanding the cortical basis of speech production and the creation of vocal prosthetics. PMID:27019106

  19. High-Resolution, Non-Invasive Imaging of Upper Vocal Tract Articulators Compatible with Human Brain Recordings

    DOE PAGES

    Bouchard, Kristofer E.; Conant, David F.; Anumanchipalli, Gopala K.; ...

    2016-03-28

    A complete neurobiological understanding of speech motor control requires determination of the relationship between simultaneously recorded neural activity and the kinematics of the lips, jaw, tongue, and larynx. Many speech articulators are internal to the vocal tract, and therefore simultaneously tracking the kinematics of all articulators is nontrivial-especially in the context of human electrophysiology recordings. Here, we describe a noninvasive, multi-modal imaging system to monitor vocal tract kinematics, demonstrate this system in six speakers during production of nine American English vowels, and provide new analysis of such data. Classification and regression analysis revealed considerable variability in the articulator-to-acoustic relationship acrossmore » speakers. Non-negative matrix factorization extracted basis sets capturing vocal tract shapes allowing for higher vowel classification accuracy than traditional methods. Statistical speech synthesis generated speech from vocal tract measurements, and we demonstrate perceptual identification. We demonstrate the capacity to predict lip kinematics from ventral sensorimotor cortical activity. These results demonstrate a multi-modal system to non-invasively monitor articulator kinematics during speech production, describe novel analytic methods for relating kinematic data to speech acoustics, and provide the first decoding of speech kinematics from electrocorticography. These advances will be critical for understanding the cortical basis of speech production and the creation of vocal prosthetics.« less

  20. D-Shaped Polarization Maintaining Fiber Sensor for Strain and Temperature Monitoring.

    PubMed

    Qazi, Hummad Habib; Mohammad, Abu Bakar; Ahmad, Harith; Zulkifli, Mohd Zamani

    2016-09-15

    A D-shaped polarization-maintaining fiber (PMF) as fiber optic sensor for the simultaneous monitoring of strain and the surrounding temperature is presented. A mechanical end and edge polishing system with aluminum oxide polishing film is utilized to perform sequential polishing on one side (lengthwise) of the PMF in order to fabricate a D-shaped cross-section. Experimental results show that the proposed sensor has high sensitivity of 46 pm/µε and 130 pm/°C for strain and temperature, respectively, which is significantly higher than other recently reported work (mainly from 2013) related to fiber optic sensors. The easy fabrication method, high sensitivity, and good linearity make this sensing device applicable in various applications such as health monitoring and spatial analysis of engineering structures.

  1. D-Shaped Polarization Maintaining Fiber Sensor for Strain and Temperature Monitoring

    PubMed Central

    Qazi, Hummad Habib; Mohammad, Abu Bakar; Ahmad, Harith; Zulkifli, Mohd Zamani

    2016-01-01

    A D-shaped polarization-maintaining fiber (PMF) as fiber optic sensor for the simultaneous monitoring of strain and the surrounding temperature is presented. A mechanical end and edge polishing system with aluminum oxide polishing film is utilized to perform sequential polishing on one side (lengthwise) of the PMF in order to fabricate a D-shaped cross-section. Experimental results show that the proposed sensor has high sensitivity of 46 pm/µε and 130 pm/°C for strain and temperature, respectively, which is significantly higher than other recently reported work (mainly from 2013) related to fiber optic sensors. The easy fabrication method, high sensitivity, and good linearity make this sensing device applicable in various applications such as health monitoring and spatial analysis of engineering structures. PMID:27649195

  2. Single-well monitoring of protein-protein interaction and phosphorylation-dephosphorylation events.

    PubMed

    Arcand, Mathieu; Roby, Philippe; Bossé, Roger; Lipari, Francesco; Padrós, Jaime; Beaudet, Lucille; Marcil, Alexandre; Dahan, Sophie

    2010-04-20

    We combined oxygen channeling assays with two distinct chemiluminescent beads to detect simultaneously protein phosphorylation and interaction events that are usually monitored separately. This novel method was tested in the ERK1/2 MAP kinase pathway. It was first used to directly monitor dissociation of MAP kinase ERK2 from MEK1 upon phosphorylation and to evaluate MAP kinase phosphatase (MKP) selectivity and mechanism of action. In addition, MEK1 and ERK2 were probed with an ATP competitor and an allosteric MEK1 inhibitor, which generated distinct phosphorylation-interaction patterns. Simultaneous monitoring of protein-protein interactions and substrate phosphorylation can provide significant mechanistic insight into enzyme activity and small molecule action.

  3. Detection of Impaired Cerebral Autoregulation Using Selected Correlation Analysis: A Validation Study

    PubMed Central

    Brawanski, Alexander

    2017-01-01

    Multimodal brain monitoring has been utilized to optimize treatment of patients with critical neurological diseases. However, the amount of data requires an integrative tool set to unmask pathological events in a timely fashion. Recently we have introduced a mathematical model allowing the simulation of pathophysiological conditions such as reduced intracranial compliance and impaired autoregulation. Utilizing a mathematical tool set called selected correlation analysis (sca), correlation patterns, which indicate impaired autoregulation, can be detected in patient data sets (scp). In this study we compared the results of the sca with the pressure reactivity index (PRx), an established marker for impaired autoregulation. Mean PRx values were significantly higher in time segments identified as scp compared to segments showing no selected correlations (nsc). The sca based approach predicted cerebral autoregulation failure with a sensitivity of 78.8% and a specificity of 62.6%. Autoregulation failure, as detected by the results of both analysis methods, was significantly correlated with poor outcome. Sca of brain monitoring data detects impaired autoregulation with high sensitivity and sufficient specificity. Since the sca approach allows the simultaneous detection of both major pathological conditions, disturbed autoregulation and reduced compliance, it may become a useful analysis tool for brain multimodal monitoring data. PMID:28255331

  4. Detection of Impaired Cerebral Autoregulation Using Selected Correlation Analysis: A Validation Study.

    PubMed

    Proescholdt, Martin A; Faltermeier, Rupert; Bele, Sylvia; Brawanski, Alexander

    2017-01-01

    Multimodal brain monitoring has been utilized to optimize treatment of patients with critical neurological diseases. However, the amount of data requires an integrative tool set to unmask pathological events in a timely fashion. Recently we have introduced a mathematical model allowing the simulation of pathophysiological conditions such as reduced intracranial compliance and impaired autoregulation. Utilizing a mathematical tool set called selected correlation analysis (sca), correlation patterns, which indicate impaired autoregulation, can be detected in patient data sets (scp). In this study we compared the results of the sca with the pressure reactivity index (PRx), an established marker for impaired autoregulation. Mean PRx values were significantly higher in time segments identified as scp compared to segments showing no selected correlations (nsc). The sca based approach predicted cerebral autoregulation failure with a sensitivity of 78.8% and a specificity of 62.6%. Autoregulation failure, as detected by the results of both analysis methods, was significantly correlated with poor outcome. Sca of brain monitoring data detects impaired autoregulation with high sensitivity and sufficient specificity. Since the sca approach allows the simultaneous detection of both major pathological conditions, disturbed autoregulation and reduced compliance, it may become a useful analysis tool for brain multimodal monitoring data.

  5. Global positioning system network analysis with phase ambiguity resolution applied to crustal deformation studies in California

    NASA Technical Reports Server (NTRS)

    Dong, Da-Nan; Bock, Yehuda

    1989-01-01

    An efficient algorithm is developed for multisession adjustment of GPS data with simultaneous orbit determination and ambiguity resolution. Application of the algorithm to the analysis of data from a five-year campaign in progress in southern and central California to monitor tectonic motions using observations by GPS satellites, demonstrates improvements in estimates of station position and satellite orbits when the phase ambiguities are resolved. Most of the phase ambiguities in the GPS network were resolved, particularly for all the baselines of geophysical interest in California.

  6. Integrating physically based simulators with Event Detection Systems: Multi-site detection approach.

    PubMed

    Housh, Mashor; Ohar, Ziv

    2017-03-01

    The Fault Detection (FD) Problem in control theory concerns of monitoring a system to identify when a fault has occurred. Two approaches can be distinguished for the FD: Signal processing based FD and Model-based FD. The former concerns of developing algorithms to directly infer faults from sensors' readings, while the latter uses a simulation model of the real-system to analyze the discrepancy between sensors' readings and expected values from the simulation model. Most contamination Event Detection Systems (EDSs) for water distribution systems have followed the signal processing based FD, which relies on analyzing the signals from monitoring stations independently of each other, rather than evaluating all stations simultaneously within an integrated network. In this study, we show that a model-based EDS which utilizes a physically based water quality and hydraulics simulation models, can outperform the signal processing based EDS. We also show that the model-based EDS can facilitate the development of a Multi-Site EDS (MSEDS), which analyzes the data from all the monitoring stations simultaneously within an integrated network. The advantage of the joint analysis in the MSEDS is expressed by increased detection accuracy (higher true positive alarms and fewer false alarms) and shorter detection time. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Monitoring supports performance in a dual-task paradigm involving a risky decision-making task and a working memory task

    PubMed Central

    Gathmann, Bettina; Schiebener, Johannes; Wolf, Oliver T.; Brand, Matthias

    2015-01-01

    Performing two cognitively demanding tasks at the same time is known to decrease performance. The current study investigates the underlying executive functions of a dual-tasking situation involving the simultaneous performance of decision making under explicit risk and a working memory task. It is suggested that making a decision and performing a working memory task at the same time should particularly require monitoring—an executive control process supervising behavior and the state of processing on two tasks. To test the role of a supervisory/monitoring function in such a dual-tasking situation we investigated 122 participants with the Game of Dice Task plus 2-back task (GDT plus 2-back task). This dual task requires participants to make decisions under risk and to perform a 2-back working memory task at the same time. Furthermore, a task measuring a set of several executive functions gathered in the term concept formation (Modified Card Sorting Test, MCST) and the newly developed Balanced Switching Task (BST), measuring monitoring in particular, were used. The results demonstrate that concept formation and monitoring are involved in the simultaneous performance of decision making under risk and a working memory task. In particular, the mediation analysis revealed that BST performance partially mediates the influence of MCST performance on the GDT plus 2-back task. These findings suggest that monitoring is one important subfunction for superior performance in a dual-tasking situation including decision making under risk and a working memory task. PMID:25741308

  8. Detection of Mouse Cough Based on Sound Monitoring and Respiratory Airflow Waveforms

    PubMed Central

    Chen, Liyan; Lai, Kefang; Lomask, Joseph Mark; Jiang, Bert; Zhong, Nanshan

    2013-01-01

    Detection for cough in mice has never yielded clearly audible sounds, so there is still a great deal of debates as to whether mice can cough in response to tussive stimuli. Here we introduce an approach for detection of mouse cough based on sound monitoring and airflow signals. 40 Female BALB/c mice were pretreated with normal saline, codeine, capasazepine or desensitized with capsaicin. Single mouse was put in a plethysmograph, exposed to aerosolized 100 µmol/L capsaicin for 3 min, followed by continuous observation for 3 min. Airflow signals of total 6 min were recorded and analyzed to detect coughs. Simultaneously, mouse cough sounds were sensed by a mini-microphone, monitored manually by an operator. When manual and automatic detection coincided, the cough was positively identified. Sound and sound waveforms were also recorded and filtered for further analysis. Body movements were observed by operator. Manual versus automated counts were compared. Seven types of airflow signals were identified by integrating manual and automated monitoring. Observation of mouse movements and analysis of sound waveforms alone did not produce meaningful data. Mouse cough numbers decreased significantly after all above drugs treatment. The Bland-Altman and consistency analysis between automatic and manual counts was 0.968 and 0.956. The study suggests that the mouse is able to present with cough, which could be detected by sound monitoring and respiratory airflow waveform changes. PMID:23555643

  9. A comparison of two ambulatory blood pressure monitors worn at the same time.

    PubMed

    Kallem, Radhakrishna R; Meyers, Kevin E C; Sawinski, Deirdre L; Townsend, Raymond R

    2013-05-01

    There are limited data in the literature comparing two simultaneously worn ambulatory blood pressure (BP) monitoring (ABPM) devices. The authors compared BPs from two monitors (Mobil-O-Graph [I.E.M., Stolberg, Germany] and Spacelabs 90207 [Spacelabs Medical, Issequah, WA]). In the nonrandomized component of the study, simultaneous 8-hour BP and heart rate data were measured by Mobil-O-Graph, consistently applied to the nondominant arm, and Spacelabs to the dominant arm on 12 untreated adults. Simultaneous 8-hour BP and heart data were obtained by the same monitors randomly assigned to a dominant or nondominant arm on 12 other untreated adults. Oscillometric BP profiles were obtained in the dominant and nondominant arms of the above 24 patients using an Accutorr (Datascope, Mahwah, NJ) device. The Spacelabs monitor recorded a 10.2-mm Hg higher systolic pressure in the nonrandomized (P=.0016) and a 7.9-mm Hg higher systolic pressure in the randomized studies (P=.00008) compared with the Mobil-O-Graph. The mean arterial pressures were 1 mm Hg to 2 mm Hg different between monitors in the two studies, and heart rates were nearly identical. Our observations, if confirmed in larger cohorts, support the concern that ABPM device manufacturers consider developing normative databases for their devices. ©2013 Wiley Periodicals, Inc.

  10. Fiber optic chemical sensors: The evolution of high- density fiber-optic DNA microarrays

    NASA Astrophysics Data System (ADS)

    Ferguson, Jane A.

    2001-06-01

    Sensors were developed for multianalyte monitoring, fermentation monitoring, lactate analysis, remote oxygen detection for use in bioremediation monitoring and in a fuel spill clean-up project, heavy metal analysis, and high density DNA microarrays. The major focus of this thesis involved creating and improving high-density DNA gene arrays. Fiber optic sensors are created using fluorescent indicators, polymeric supports, and optical fiber substrates. The fluorescent indicator is entrapped in a polymer layer and attached to the tip of the optical fiber. The tip of the fiber bearing the sensing layer (the distal end) is placed in the sample of interest while the other end of the fiber (the proximal end) is connected to an analysis system. Any length of fiber can be used without compromising the integrity or sensitivity of the system. A fiber optic oxygen sensor was designed incorporating an oxygen sensitive fluorescent dye and a gas permeable polymer attached to an optical fiber. The construction simplicity and ruggedness of the sensor enabled its deployment for in situ chemical oxidation and bioremediation studies. Optical fibers were also used as the substrate to detect biomolecules in solution. To monitor bioprocesses, the production of the analyte of interest must be coupled with a species that is optically measurable. For example, oxygen is consumed in many metabolic functions. The fiber optic oxygen sensor is equipped with an additional sensing layer. Upon contact with a specific biochemical in the sample, a reaction occurs in the additional sensing layer that either consumes or produces oxygen. This dual layer system was used to monitor the presence of lactate, an important metabolite for clinical and bioprocess analysis. In many biological and environmental systems, the generation of one species occurs coincidentally with the generation or consumption of another species. A multianalyte sensor was prepared that can monitor the simultaneous activity of pH, CO2 and O2. This sensor is useful for monitoring bioprocesses such as (beer) fermentation and for clinical situations such as blood gas analysis. DNA sensors were created by attaching short single strands of DNA (probes) to the fiber tip. A matching single strand (target) forms a strong interacting pair with the probe upon contact. The target strands in a sample are labeled with a fluorescent dye. When a probe-target pair is formed and excitation light is sent down the fiber, the fiber bearing the pair emits light that is captured and detected. A high density DNA array was created by isolating thousands of discrete DNA sensors on the tip of an imaging optical fiber. This array was made possible by the formation of microwells on the imaging fiber tip. Microspheres functionalized with DNA were placed in the wells of the fiber and each microsphere was independently and simultaneously monitored. (Abstract shortened by UMI.)

  11. In-line and real-time process monitoring of a freeze drying process using Raman and NIR spectroscopy as complementary process analytical technology (PAT) tools.

    PubMed

    De Beer, T R M; Vercruysse, P; Burggraeve, A; Quinten, T; Ouyang, J; Zhang, X; Vervaet, C; Remon, J P; Baeyens, W R G

    2009-09-01

    The aim of the present study was to examine the complementary properties of Raman and near infrared (NIR) spectroscopy as PAT tools for the fast, noninvasive, nondestructive and in-line process monitoring of a freeze drying process. Therefore, Raman and NIR probes were built in the freeze dryer chamber, allowing simultaneous process monitoring. A 5% (w/v) mannitol solution was used as model for freeze drying. Raman and NIR spectra were continuously collected during freeze drying (one Raman and NIR spectrum/min) and the spectra were analyzed using principal component analysis (PCA) and multivariate curve resolution (MCR). Raman spectroscopy was able to supply information about (i) the mannitol solid state throughout the entire process, (ii) the endpoint of freezing (endpoint of mannitol crystallization), and (iii) several physical and chemical phenomena occurring during the process (onset of ice nucleation, onset of mannitol crystallization). NIR spectroscopy proved to be a more sensitive tool to monitor the critical aspects during drying: (i) endpoint of ice sublimation and (ii) monitoring the release of hydrate water during storage. Furthermore, via NIR spectroscopy some Raman observations were confirmed: start of ice nucleation, end of mannitol crystallization and solid state characteristics of the end product. When Raman and NIR monitoring were performed on the same vial, the Raman signal was saturated during the freezing step caused by reflected NIR light reaching the Raman detector. Therefore, NIR and Raman measurements were done on a different vial. Also the importance of the position of the probes (Raman probe above the vial and NIR probe at the bottom of the sidewall of the vial) in order to obtain all required critical information is outlined. Combining Raman and NIR spectroscopy for the simultaneous monitoring of freeze drying allows monitoring almost all critical freeze drying process aspects. Both techniques do not only complement each other, they also provided mutual confirmation of specific conclusions.

  12. Selective pelvic autonomic nerve stimulation with simultaneous intraoperative monitoring of internal anal sphincter and bladder innervation.

    PubMed

    Kneist, W; Kauff, D W; Koch, K P; Schmidtmann, I; Heimann, A; Hoffmann, K P; Lang, H

    2011-01-01

    Pelvic autonomic nerve preservation avoids postoperative functional disturbances. The aim of this feasibility study was to develop a neuromonitoring system with simultaneous intraoperative verification of internal anal sphincter (IAS) activity and intravesical pressure. 14 pigs underwent low anterior rectal resection. During intermittent bipolar electric stimulation of the inferior hypogastric plexus (IHP) and the pelvic splanchnic nerves (PSN), electromyographic signals of the IAS and manometry of the urinary bladder were observed simultaneously. Stimulation of IHP and PSN as well as simultaneous intraoperative monitoring could be realized with an adapted neuromonitoring device. Neurostimulation resulted in either bladder or IAS activation or concerted activation of both. Intravesical pressure increase as well as amplitude increase of the IAS neuromonitoring signal did not differ significantly between stimulation of IHP and PSN [6.0 cm H(2)O (interquartile range [IQR] 3.5-9.0) vs. 6.0 cm H(2)O (IQR 3.0-10.0) and 12.1 μV (IQR 3.0-36.7) vs. 40.1 μV (IQR 9.0-64.3)] (p > 0.05). Pelvic autonomic nerve stimulation with simultaneous intraoperative monitoring of IAS and bladder innervation is feasible. The method may enable neuromonitoring with increasing selectivity for pelvic autonomic nerve preservation. Copyright © 2011 S. Karger AG, Basel.

  13. Simultaneous Time, Wavelength and Intensity Measurement of Optical Memory Subsystems

    DTIC Science & Technology

    1998-07-01

    SIMULTANEOUS TIME, WAVELENGTH AND INTENSITY MEASUREMENT PE - 61102F OF OPTICAL MEMORY SUBSYSTEMS PR - 2300 6. AUTHOR( S ) TA - 06 WU -03 Joseph Osman and...Rebecca Bussjager 7. PERFORMING ORGANIZATION NAME( S ) AND ADDRESS(ES) 8. PERFORMING ORGANIZATION REPORT NUMBER AFRL/SNDP25 letnic AFRL-SN-RS-TR- 1998...12025 Electronic Pky Rome, NY 13441-4515 9. SPONSORING/MONITORING AGENCY NAME( S ) AND ADDRESS(ES) 10. SPONSORING/MONITORING AGENCY REPORT NUMBER

  14. Simultaneous laser-induced fluorescence and scattering detection of individual particles separated by capillary electrophoresis.

    PubMed

    Andreyev, Dmitry; Arriaga, Edgar A

    2007-07-15

    This technical note describes a detector capable of simultaneously monitoring scattering and fluorescence signals of individual particles separated by capillary electrophoresis. Due to its nonselective nature, scattering alone is not sufficient to identify analyte particles. However, when the analyte particles are fluorescent, the detector described here is able to identify simultaneously occurring scattering and fluorescent signals, even when contaminating particles (i.e., nonfluorescent) are present. Both fluorescent polystyrene particles and 10-nonyl acridine orange (NAO)-labeled mitochondria were used as models. Fluorescence versus scattering (FVS) plots made it possible to identify two types of particles and a contaminant in a mixture of polystyrene particles. We also analyzed NAO-labeled mitochondria before and after cryogenic storage; the mitochondria FVS plots changed with storage, which suggests that the detector reported here is suitable for monitoring subtle changes in mitochondrial morphology that would not be revealed by monitoring only fluorescence or scattering signals.

  15. Implementation of in-line infrared monitor in full-scale anaerobic digestion process.

    PubMed

    Spanjers, H; Bouvier, J C; Steenweg, P; Bisschops, I; van Gils, W; Versprille, B

    2006-01-01

    During start up but also during normal operation, anaerobic reactor systems should be run and monitored carefully to secure trouble-free operation, because the process is vulnerable to disturbances such as temporary overloading, biomass wash out and influent toxicity. The present method of monitoring is usually by manual sampling and subsequent laboratory analysis. Data collection, processing and feedback to system operation is manual and ad hoc, and involves high-level operator skills and attention. As a result, systems tend to be designed at relatively conservative design loading rates resulting in significant over-sizing of reactors and thus increased systems cost. It is therefore desirable to have on-line and continuous access to performance data on influent and effluent quality. Relevant variables to indicate process performance include VFA, COD, alkalinity, sulphate, and, if aerobic post-treatment is considered, total nitrogen, ammonia and nitrate. Recently, mid-IR spectrometry was demonstrated on a pilot scale to be suitable for in-line simultaneous measurement of these variables. This paper describes a full-scale application of the technique to test its ability to monitor continuously and without human intervention the above variables simultaneously in two process streams. For VFA, COD, sulphate, ammonium and TKN good agreement was obtained between in-line and manual measurements. During a period of six months the in-line measurements had to be interrupted several times because of clogging. It appeared that the sample pre-treatment unit was not able to cope with high solids concentrations all the time.

  16. A simultaneous multimodal imaging system for tissue functional parameters

    NASA Astrophysics Data System (ADS)

    Ren, Wenqi; Zhang, Zhiwu; Wu, Qiang; Zhang, Shiwu; Xu, Ronald

    2014-02-01

    Simultaneous and quantitative assessment of skin functional characteristics in different modalities will facilitate diagnosis and therapy in many clinical applications such as wound healing. However, many existing clinical practices and multimodal imaging systems are subjective, qualitative, sequential for multimodal data collection, and need co-registration between different modalities. To overcome these limitations, we developed a multimodal imaging system for quantitative, non-invasive, and simultaneous imaging of cutaneous tissue oxygenation and blood perfusion parameters. The imaging system integrated multispectral and laser speckle imaging technologies into one experimental setup. A Labview interface was developed for equipment control, synchronization, and image acquisition. Advanced algorithms based on a wide gap second derivative reflectometry and laser speckle contrast analysis (LASCA) were developed for accurate reconstruction of tissue oxygenation and blood perfusion respectively. Quantitative calibration experiments and a new style of skinsimulating phantom were designed to verify the accuracy and reliability of the imaging system. The experimental results were compared with a Moor tissue oxygenation and perfusion monitor. For In vivo testing, a post-occlusion reactive hyperemia (PORH) procedure in human subject and an ongoing wound healing monitoring experiment using dorsal skinfold chamber models were conducted to validate the usability of our system for dynamic detection of oxygenation and perfusion parameters. In this study, we have not only setup an advanced multimodal imaging system for cutaneous tissue oxygenation and perfusion parameters but also elucidated its potential for wound healing assessment in clinical practice.

  17. Hyperspectral techniques in analysis of oral dosage forms.

    PubMed

    Hamilton, Sara J; Lowell, Amanda E; Lodder, Robert A

    2002-10-01

    Pharmaceutical oral dosage forms are used in this paper to test the sensitivity and spatial resolution of hyperspectral imaging instruments. The first experiment tested the hypothesis that a near-infrared (IR) tunable diode-based remote sensing system is capable of monitoring degradation of hard gelatin capsules at a relatively long distance (0.5 km). Spectra from the capsules were used to differentiate among capsules exposed to an atmosphere containing 150 ppb formaldehyde for 0, 2, 4, and 8 h. Robust median-based principal component regression with Bayesian inference was employed for outlier detection. The second experiment tested the hypothesis that near-IR imaging spectrometry of tablets permits the identification and composition of multiple individual tablets to be determined simultaneously. A near-IR camera was used to collect thousands of spectra simultaneously from a field of blister-packaged tablets. The number of tablets that a typical near-IR camera can currently analyze simultaneously was estimated to be approximately 1300. The bootstrap error-adjusted single-sample technique chemometric-imaging algorithm was used to draw probability-density contour plots that revealed tablet composition. The single-capsule analysis provides an indication of how far apart the sample and instrumentation can be and still maintain adequate signal-to-noise ratio (S/N), while the multiple-tablet imaging experiment gives an indication of how many samples can be analyzed simultaneously while maintaining an adequate S/N and pixel coverage on each sample.

  18. In vivo continuous and simultaneous monitoring of brain energy substrates with a multiplex amperometric enzyme-based biosensor device.

    PubMed

    Cordeiro, C A; de Vries, M G; Ngabi, W; Oomen, P E; Cremers, T I F H; Westerink, B H C

    2015-05-15

    Enzyme-based amperometric biosensors are widely used for monitoring key biomarkers. In experimental neuroscience there is a growing interest in in vivo continuous and simultaneous monitoring of metabolism-related biomarkers, like glucose, lactate and pyruvate. The use of multiplex biosensors will provide better understanding of brain energy metabolism and its role in neuropathologies such as diabetes, ischemia, and epilepsy. We have developed and characterized an implantable multiplex microbiosensor device (MBD) for simultaneous and continuous in vivo monitoring of glucose, lactate, and pyruvate. First, we developed and characterized amperometric microbiosensors for monitoring lactate and pyruvate. In vitro evaluation allowed us to choose the most suitable biosensors for incorporation into the MBD, along with glucose and background biosensors. Fully assembled MBDs were characterized in vitro. The calculated performance parameters (LOD, LR, LRS, IMAX and appKM) showed that the multiplex MBD was highly selective and sensitive (LRS≥100 nA/mM) for each analyte and within an adequate range for in vivo application. Finally, MBDs were implanted in the mPFC of anesthetized adult male Wistar rats for in vivo evaluation. Following an equilibration period, baseline brain levels of glucose (1.3±0.2 mM), lactate (1.5±0.4 mM) and pyruvate (0.3±0.1 mM) were established. Subsequently, the MBDs recorded the responses of the animals when submitted to hyperglycemic (40% glucose i.v.) and hypoglycemic (5 U/kg insulin i.v.) challenges. Afterwards, MBDs were recalibrated to convert electrochemical readings into accurate substrate concentrations and to assess biofouling. The presented MBD can monitor simultaneously multiple biomarkers in vivo. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Estimation of CO2 saturation during both CO2 drainage and imbibition processes based on both seismic velocity and electrical resistivity measurements

    NASA Astrophysics Data System (ADS)

    Kim, Jongwook; Nam, Myung Jin; Matsuoka, Toshifumi

    2013-10-01

    In order to monitor injected carbon dioxide (CO2), simultaneous measurements of seismic velocity and electrical resistivity are employed during the drainage (CO2 injection) and imbibition (water injection) processes of a Berea sandstone. Supercritical CO2 (10 MPa at 40 ºC) was injected into a water-saturated Berea sandstone in the drainage stage and monitored via simultaneous measurements. After the injection of supercritical CO2, fresh distilled water was injected into the CO2-injected sandstone during the imbibition stage. Electrical resistivity and P-wave velocity measurements acquired during the drainage and imbibition stages were employed to evaluate CO2 saturations (SCO2) based on the resistivity index and the Gassmann fluid-substitution equations, respectively. Comparing estimated values for SCO2 saturation against those from volume-derived SCO2, based on analysis on injected and drained fluid volumes in the drainage process, we conclude that Gassmann-Brie and resistivity index are suitable for the evaluation based on P-wave velocity and electrical resistivity, respectively. Rt-based estimation properly tracks the variation in SCO2 even when SCO2 is large (>0.15), while Vp-based estimation is sensitive to the variation in SCO2 when SCO2 is small (<0.1). Employing the Gassmann-Brie and resistivity index, estimation of variation in SCO2 based on the simultaneous measurements provides the upper and lower bounds of SCO2 even when SCO2 is large (>0.1), while properly estimating SCO2 when SCO2 is small (<0.1). Monitoring the CO2 imbibition process confirms residual CO2 saturation within the sample.

  20. Efficient use of retention time for the analysis of 302 drugs in equine plasma by liquid chromatography-MS/MS with scheduled multiple reaction monitoring and instant library searching for doping control.

    PubMed

    Liu, Ying; Uboh, Cornelius E; Soma, Lawrence R; Li, Xiaoqing; Guan, Fuyu; You, Youwen; Chen, Jin-Wen

    2011-09-01

    Multiple drug target analysis (MDTA) used in doping control is more efficient than single drug target analysis (SDTA). The number of drugs with the potential for abuse is so extensive that full coverage is not possible with SDTA. To address this problem, a liquid chromatography tandem mass spectrometric method was developed for simultaneous analysis of 302 drugs using a scheduled multiple reaction monitoring (s-MRM) algorithm. With a known retention time of an analyte, the s-MRM algorithm monitors each MRM transition only around its expected retention time. Analytes were recovered from plasma by liquid-liquid extraction. Information-dependent acquisition (IDA) functionality was used to combine s-MRM with enhanced product ion (EPI) scans within the same chromatographic analysis. An EPI spectrum library was also generated for rapid identification of analytes. Analysis time for the 302 drugs was 7 min. Scheduled MRM improved the quality of the chromatograms, signal response, reproducibility, and enhanced signal-to-noise ratio (S/N), resulting in more data points. Reduction in total cycle time from 2.4 s in conventional MRM (c-MRM) to 1 s in s-MRM allowed completion of the EPI scan at the same time. The speed for screening and identification of multiple drugs in equine plasma for doping control analysis was greatly improved by this method.

  1. A risk-adjusted O-E CUSUM with monitoring bands for monitoring medical outcomes.

    PubMed

    Sun, Rena Jie; Kalbfleisch, John D

    2013-03-01

    In order to monitor a medical center's survival outcomes using simple plots, we introduce a risk-adjusted Observed-Expected (O-E) Cumulative SUM (CUSUM) along with monitoring bands as decision criterion.The proposed monitoring bands can be used in place of a more traditional but complicated V-shaped mask or the simultaneous use of two one-sided CUSUMs. The resulting plot is designed to simultaneously monitor for failure time outcomes that are "worse than expected" or "better than expected." The slopes of the O-E CUSUM provide direct estimates of the relative risk (as compared to a standard or expected failure rate) for the data being monitored. Appropriate rejection regions are obtained by controlling the false alarm rate (type I error) over a period of given length. Simulation studies are conducted to illustrate the performance of the proposed method. A case study is carried out for 58 liver transplant centers. The use of CUSUM methods for quality improvement is stressed. Copyright © 2013, The International Biometric Society.

  2. Experimental application of OMA solutions on the model of industrial structure

    NASA Astrophysics Data System (ADS)

    Mironov, A.; Mironovs, D.

    2017-10-01

    It is very important and sometimes even vital to maintain reliability of industrial structures. High quality control during production and structural health monitoring (SHM) in exploitation provides reliable functioning of large, massive and remote structures, like wind generators, pipelines, power line posts, etc. This paper introduces a complex of technological and methodical solutions for SHM and diagnostics of industrial structures, including those that are actuated by periodic forces. Solutions were verified on a wind generator scaled model with integrated system of piezo-film deformation sensors. Simultaneous and multi-patch Operational Modal Analysis (OMA) approaches were implemented as methodical means for structural diagnostics and monitoring. Specially designed data processing algorithms provide objective evaluation of structural state modification.

  3. USE OF CITIZEN BIRD POPULATION MONITORING DATA FOR ECOLOGICAL RISK ASSESSMENT

    EPA Science Inventory

    Birds are among the most conspicuous and easily monitored indicators of environmental health and change. Although volunteer avian monitoring ('citizen science') programs provide unique opportunities to gather data at fine and broad geographic scales simultaneously, and over long...

  4. Chirped fiber Bragg grating written in highly birefringent fiber in simultaneous strain and temperature monitoring.

    PubMed

    Bieda, Marcin S; Sobotka, Piotr; Woliński, Tomasz R

    2017-02-20

    A new sensor configuration is proposed for simultaneous strain and temperature monitoring in a composite material that is based on a chirped fiber Bragg grating (CFBG) written in a highly birefringent (HB) polarization-maintaining fiber. The sensor is designed in the reflective configuration in which the CFBG acts both as a reflector and a sensing element. Since CFBG and HB fiber induce changes in the state of polarization (SOP), interference between polarization modes in the reflected spectrum is observed and analyzed. We used a simple readout setup to enable fast, linear operation of strain sensing as well simultaneous strain and temperature measurements in the composite.

  5. Gas monitoring onboard ISS using FTIR spectroscopy

    NASA Astrophysics Data System (ADS)

    Gisi, Michael; Stettner, Armin; Seurig, Roland; Honne, Atle; Witt, Johannes; Rebeyre, Pierre

    2017-06-01

    In the confined, enclosed environment of a spacecraft, the air quality must be monitored continuously in order to safeguard the crew's health. For this reason, OHB builds the ANITA2 (Analysing Interferometer for Ambient Air) technology demonstrator for trace gas monitoring onboard the International Space Station (ISS). The measurement principle of ANITA2 is based on the Fourier Transform Infrared (FTIR) technology with dedicated gas analysis software from the Norwegian partner SINTEF. This combination proved to provide high sensitivity, accuracy and precision for parallel measurements of 33 trace gases simultaneously onboard ISS by the precursor instrument ANITA1. The paper gives a technical overview about the opto-mechanical components of ANITA2, such as the interferometer, the reference Laser, the infrared source and the gas cell design and a quick overview about the gas analysis. ANITA2 is very well suited for measuring gas concentrations specifically but not limited to usage onboard spacecraft, as no consumables are required and measurements are performed autonomously. ANITA2 is a programme under the contract of the European Space Agency, and the air quality monitoring system is a stepping stone into the future, as a precursor system for manned exploration missions.

  6. Optimal Design of Multitype Groundwater Monitoring Networks Using Easily Accessible Tools.

    PubMed

    Wöhling, Thomas; Geiges, Andreas; Nowak, Wolfgang

    2016-11-01

    Monitoring networks are expensive to establish and to maintain. In this paper, we extend an existing data-worth estimation method from the suite of PEST utilities with a global optimization method for optimal sensor placement (called optimal design) in groundwater monitoring networks. Design optimization can include multiple simultaneous sensor locations and multiple sensor types. Both location and sensor type are treated simultaneously as decision variables. Our method combines linear uncertainty quantification and a modified genetic algorithm for discrete multilocation, multitype search. The efficiency of the global optimization is enhanced by an archive of past samples and parallel computing. We demonstrate our methodology for a groundwater monitoring network at the Steinlach experimental site, south-western Germany, which has been established to monitor river-groundwater exchange processes. The target of optimization is the best possible exploration for minimum variance in predicting the mean travel time of the hyporheic exchange. Our results demonstrate that the information gain of monitoring network designs can be explored efficiently and with easily accessible tools prior to taking new field measurements or installing additional measurement points. The proposed methods proved to be efficient and can be applied for model-based optimal design of any type of monitoring network in approximately linear systems. Our key contributions are (1) the use of easy-to-implement tools for an otherwise complex task and (2) yet to consider data-worth interdependencies in simultaneous optimization of multiple sensor locations and sensor types. © 2016, National Ground Water Association.

  7. 2006 Pathogen and Toxin Concentration Systems for Water Monitoring

    DTIC Science & Technology

    2012-07-24

    design and construct a compact, portable automated device enabling the simultaneous concentration of protozoa , bacteria, bacterial spores, algae and...portable automated device enabling the simultaneous concentration of protozoa , bacteria, bacterial spores, algae and viruses from large volumes of various...construct a compact, portable automated device enabling the simultaneous concentration of protozoa , bacteria, bacterial spores, algae and viruses

  8. A Compact Polarization Imager

    NASA Technical Reports Server (NTRS)

    Thompson, Karl E.; Rust, David M.; Chen, Hua

    1995-01-01

    A new type of image detector has been designed to analyze the polarization of light simultaneously at all picture elements (pixels) in a scene. The Integrated Dual Imaging Detector (IDID) consists of a polarizing beamsplitter bonded to a custom-designed charge-coupled device with signal-analysis circuitry, all integrated on a silicon chip. The IDID should simplify the design and operation of imaging polarimeters and spectroscopic imagers used, for example, in atmospheric and solar research. Other applications include environmental monitoring and robot vision. Innovations in the IDID include two interleaved 512 x 1024 pixel imaging arrays (one for each polarization plane), large dynamic range (well depth of 10(exp 6) electrons per pixel), simultaneous readout and display of both images at 10(exp 6) pixels per second, and on-chip analog signal processing to produce polarization maps in real time. When used with a lithium niobate Fabry-Perot etalon or other color filter that can encode spectral information as polarization, the IDID can reveal tiny differences between simultaneous images at two wavelengths.

  9. The Use of Multidimensional Image-Based Analysis to Accurately Monitor Cell Growth in 3D Bioreactor Culture

    PubMed Central

    Baradez, Marc-Olivier; Marshall, Damian

    2011-01-01

    The transition from traditional culture methods towards bioreactor based bioprocessing to produce cells in commercially viable quantities for cell therapy applications requires the development of robust methods to ensure the quality of the cells produced. Standard methods for measuring cell quality parameters such as viability provide only limited information making process monitoring and optimisation difficult. Here we describe a 3D image-based approach to develop cell distribution maps which can be used to simultaneously measure the number, confluency and morphology of cells attached to microcarriers in a stirred tank bioreactor. The accuracy of the cell distribution measurements is validated using in silico modelling of synthetic image datasets and is shown to have an accuracy >90%. Using the cell distribution mapping process and principal component analysis we show how cell growth can be quantitatively monitored over a 13 day bioreactor culture period and how changes to manufacture processes such as initial cell seeding density can significantly influence cell morphology and the rate at which cells are produced. Taken together, these results demonstrate how image-based analysis can be incorporated in cell quality control processes facilitating the transition towards bioreactor based manufacture for clinical grade cells. PMID:22028809

  10. The use of multidimensional image-based analysis to accurately monitor cell growth in 3D bioreactor culture.

    PubMed

    Baradez, Marc-Olivier; Marshall, Damian

    2011-01-01

    The transition from traditional culture methods towards bioreactor based bioprocessing to produce cells in commercially viable quantities for cell therapy applications requires the development of robust methods to ensure the quality of the cells produced. Standard methods for measuring cell quality parameters such as viability provide only limited information making process monitoring and optimisation difficult. Here we describe a 3D image-based approach to develop cell distribution maps which can be used to simultaneously measure the number, confluency and morphology of cells attached to microcarriers in a stirred tank bioreactor. The accuracy of the cell distribution measurements is validated using in silico modelling of synthetic image datasets and is shown to have an accuracy >90%. Using the cell distribution mapping process and principal component analysis we show how cell growth can be quantitatively monitored over a 13 day bioreactor culture period and how changes to manufacture processes such as initial cell seeding density can significantly influence cell morphology and the rate at which cells are produced. Taken together, these results demonstrate how image-based analysis can be incorporated in cell quality control processes facilitating the transition towards bioreactor based manufacture for clinical grade cells.

  11. Integrated photovoltaic (PV) monitoring system

    NASA Astrophysics Data System (ADS)

    Mahinder Singh, Balbir Singh; Husain, NurSyahidah; Mohamed, Norani Muti

    2012-09-01

    The main aim of this research work is to design an accurate and reliable monitoring system to be integrated with solar electricity generating system. The performance monitoring system is required to ensure that the PVEGS is operating at an optimum level. The PV monitoring system is able to measure all the important parameters that determine an optimum performance. The measured values are recorded continuously, as the data acquisition system is connected to a computer, and data is stored at fixed intervals. The data can be locally used and can also be transmitted via internet. The data that appears directly on the local monitoring system is displayed via graphical user interface that was created by using Visual basic and Apache software was used for data transmission The accuracy and reliability of the developed monitoring system was tested against the data that captured simultaneously by using a standard power quality analyzer device. The high correlation which is 97% values indicates the level of accuracy of the monitoring system. The aim of leveraging on a system for continuous monitoring system is achieved, both locally, and can be viewed simultaneously at a remote system.

  12. Audio distribution and Monitoring Circuit

    NASA Technical Reports Server (NTRS)

    Kirkland, J. M.

    1983-01-01

    Versatile circuit accepts and distributes TV audio signals. Three-meter audio distribution and monitoring circuit provides flexibility in monitoring, mixing, and distributing audio inputs and outputs at various signal and impedance levels. Program material is simultaneously monitored on three channels, or single-channel version built to monitor transmitted or received signal levels, drive speakers, interface to building communications, and drive long-line circuits.

  13. Mobile patient monitoring based on impedance-loaded SAW-sensors.

    PubMed

    Karilainen, Anna; Finnberg, Thomas; Uelzen, Thorsten; Dembowski, Klaus; Müller, Jörg

    2004-11-01

    A remotely requestable, passive, short-range sensor network for measuring small voltages is presented. The sensor system is able to simultaneously monitor six small voltages in millivolt-range, and it can be used for Holter-electrocardiogram (ECG) and other biopotential monitoring, or in industrial applications. The sensors are based on a surface acoustic wave (SAW) delay line with voltage-dependent, impedance loading on a reflector interdigital transducer (IDT). The load circuit impedance is varied by the capacitance of the voltage-controlled varactor. High resolution is achieved by developing a MOS-capacitor with a thin oxide, low flat-band voltage, and zero-voltage capacitance in the space-charge region, as well as a high-Q-microcoil by thick metal electroplating. Simultaneous monitoring of multiple potentials is realized by time-division-multiplexing of different sensor signals.

  14. Simultaneous analysis of 17 diuretics in dietary supplements by HPLC and LC-MS/MS.

    PubMed

    Woo, H; Kim, J W; Han, K M; Lee, J H; Hwang, I S; Lee, J H; Kim, J; Kweon, S J; Cho, S; Chae, K R; Han, S Y; Kim, J

    2013-01-01

    In order to test health foods for illegally added diuretics for weight loss, we developed simple, rapid, selective, and sensitive methods using HPLC and LC-MS/MS for the simultaneous analysis of 17 diuretics in dietary supplements. HPLC conditions were set with a Capcell-pak C18, using a mobile phase consisting of gradient conditions, UV detection at 254 nm and validated for linearity (r(2)> 0.999), precision (CV ≤ 3%), recoveries (90.4-102.8%) and reproducibility. Identification and quantification of 17 diuretics were accomplished by ion-spray LC-MS/MS using multiple reaction monitoring (MRM). The chromatographic separation was carried out under the reversed-phase mechanism on an HSS-T3 column. The LC-MS/MS method was validated for linearity (r(2)> 0.99) and precision (CV < 13%). Sixteen dietary supplements were tested with the developed methods. Diuretics were not detected in all samples. Extraction recovery was also investigated and the extraction recoveries in different formulations were from 88% to 110% and from 81% to 116% using HPLC and LC-MS/MS, respectively. There was no significant difference in recoveries in the type of dietary supplements. Based on this result, the developed methods to monitor illegal drug adulterations in dietary supplements using HPLC and LC-MS/MS are simple, fast and reliable. Therefore, it is applicable to routine drug-adulteration screening.

  15. FTIR gas analysis with improved sensitivity and selectivity for CWA and TIC detection

    NASA Astrophysics Data System (ADS)

    Phillips, Charles M.; Tan, Huwei

    2010-04-01

    This presentation describes the use of an FTIR (Fourier Transform Infrared)-based spectrometer designed to continuously monitor ambient air for the presence of chemical warfare agents (CWAs) and toxic industrial chemicals (TICs). The necessity of a reliable system capable of quickly and accurately detecting very low levels of CWAs and TICs while simultaneously retaining a negligible false alarm rate will be explored. Technological advancements in FTIR sensing have reduced noise while increasing selectivity and speed of detection. These novel analyzer design characteristics are discussed in detail and descriptions are provided which show how optical throughput, gas cell form factor, and detector response are optimized. The hardware and algorithms described here will explain why this FTIR system is very effective for the simultaneous detection and speciation of a wide variety of toxic compounds at ppb concentrations. Analytical test data will be reviewed demonstrating the system's sensitivity to and selectivity for specific CWAs and TICs; this will include recent data acquired as part of the DHS ARFCAM (Autonomous Rapid Facility Chemical Agent Monitor) project. These results include analyses of the data from live agent testing for the determination of CWA detection limits, immunity to interferences, detection times, residual noise analysis and false alarm rates. Sensing systems such as this are critical for effective chemical hazard identification which is directly relevant to the CBRNE community.

  16. PRECISE ANGLE MONITOR BASED ON THE CONCEPT OF PENCIL-BEAM INTERFEROMETRY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    QIAN,S.; TAKACS,P.

    2000-07-30

    The precise angle monitoring is a very important metrology task for research, development and industrial applications. Autocollimator is one of the most powerful and widely applied instruments for small angle monitoring, which is based on the principle of geometric optics. In this paper the authors introduce a new precise angle monitoring system, Pencil-beam Angle Monitor (PAM), base on pencil beam interferometry. Its principle of operation is a combination of physical and geometrical optics. The angle calculation method is similar to the autocollimator. However, the autocollimator creates a cross image but the precise pencil-beam angle monitoring system produces an interference fringemore » on the focal plane. The advantages of the PAM are: high angular sensitivity, long-term stability character making angle monitoring over long time periods possible, high measurement accuracy in the order of sub-microradian, simultaneous measurement ability in two perpendicular directions or on two different objects, dynamic measurement possibility, insensitive to the vibration and air turbulence, automatic display, storage and analysis by use of the computer, small beam diameter making the alignment extremely easy and longer test distance. Some test examples are presented.« less

  17. [Simultaneous determination of 4 diterpenoids in Rabdosia japonica var.glaucocalyx by HPLC-ESI-MS/MS and cluster analysis].

    PubMed

    Tian, Ting-Ting; Ma, Ying-Hua; Xie, Wei-Wei; Jin, Yi-Ran; Xu, Hui-Jun; Zhang, Lan-Tong; Du, Ying-Feng

    2016-01-01

    A quick HPLC-ESI-MS/MS method was established for simultaneous determination of four major diterpenoids in Rabdosia japonica var.glaucocalyx, including glaucocalyxin A, oridonin, hebeirubesensin and enmenol. Analysis was performed on an Agilent ZORBAX SB-C18(4.6 mm×250 mm, 5 μm ) column eluted in a gradient program with methanol and water. The flow rate was 0.8 mL•min⁻¹. Multiple reaction monitoring (MRM) scanning mode was performed in negative ion switching mode to apply for the quantitative determination. The calibration curves for the above four compounds were linear in corresponding injection amount. The average recoveries of the compounds ranged from 92.40% to 105.9%, with RSDs of 1.7%-6.5%. The method is simple, rapid, accurate with good repeatability, which can provide a reference for overcalling evaluation the quality of R. japonica var.glaucocalyx. The result of cluster analysis- showed that the quality of R. japonica glaucocalyx var. greatly varied between areas and parts. Copyright© by the Chinese Pharmaceutical Association.

  18. Mini-Mega-TORTORA wide-field monitoring system with sub-second temporal resolution: first year of operation

    NASA Astrophysics Data System (ADS)

    Karpov, S.; Beskin, G.; Biryukov, A.; Bondar, S.; Ivanov, E.; Katkova, E.; Perkov, A.; Sasyuk, V.

    2016-12-01

    Here we present the summary of first years of operation and the first results of a novel 9-channel wide-field optical monitoring system with sub-second temporal resolution, Mini-Mega-TORTORA (MMT-9), which is in operation now at Special Astrophysical Observatory on Russian Caucasus. The system is able to observe the sky simultaneously in either wide (˜900 square degrees) or narrow (˜100 square degrees) fields of view, either in clear light or with any combination of color (Johnson-Cousins B, V or R) and polarimetric filters installed, with exposure times ranging from 0.1 s to hundreds of seconds. The real-time system data analysis pipeline performs automatic detection of rapid transient events, both near-Earth and extragalactic. The objects routinely detected by MMT include faint meteors and artificial satellites. The pipeline for a longer time scales variability analysis is still in development.

  19. Mini-MegaTORTORA wide-field monitoring system with sub-second temporal resolution: observation of transient events

    NASA Astrophysics Data System (ADS)

    Karpov, S.; Beskin, G.; Biryukov, A.; Bondar, S.; Ivanov, E.; Katkova, E.; Perkov, A.; Sasyuk, V.

    2016-06-01

    Here we present a summary of first years of operation and first results of a novel 9-channel wide-field optical monitoring system with sub-second temporal resolution, Mini-MegaTORTORA (MMT-9), which is in operation now at Special Astrophysical Observatory on Russian Caucasus. The system is able to observe the sky simultaneously in either wide (~900 square degrees) or narrow (~100 square degrees) fields of view, either in clear light or with any combination of color (Johnson-Cousins B, V or R) and polarimetric filters installed, with exposure times ranging from 0.1 s to hundreds of seconds. The real-time system data analysis pipeline performs automatic detection of rapid transient events, both near-Earth and extragalactic. The objects routinely detected by MMT include faint meteors and artificial satellites. The pipeline for a longer time scales variability analysis is still in development.

  20. HRV analysis and blood pressure monitoring on weighing scale using BCG.

    PubMed

    Shin, Jae Hyuk; Park, Kwang Suk

    2012-01-01

    Using the Ballistocardiogram(BCG) measured on weighing scale, heart rate variability(HRV) and blood pressure were estimated. BCG was measured while subjects were on weighing scale in resting state and under the Valsalva maneuver and static exercise condition to induce the change in cardiac autonomic rhythm. Time domain, frequency domain and nonlinear HRV parameters were estimated from the measured BCG and compared with the ones calculated from ECG measured simultaneously. For blood pressure(BP) estimation, ECG was measured additionally on the feet using dry electrodes simultaneously installed on weighing scale and R-J intervals were extracted as a BP correlated parameter at every beat cycle. HRV estimation results shows the correlation higher than 0.97, and the estimated BP was similar to the measured BP with a reliable correlations.

  1. Multiplexed 3D FRET imaging in deep tissue of live embryos

    PubMed Central

    Zhao, Ming; Wan, Xiaoyang; Li, Yu; Zhou, Weibin; Peng, Leilei

    2015-01-01

    Current deep tissue microscopy techniques are mostly restricted to intensity mapping of fluorophores, which significantly limit their applications in investigating biochemical processes in vivo. We present a deep tissue multiplexed functional imaging method that probes multiple Förster resonant energy transfer (FRET) sensors in live embryos with high spatial resolution. The method simultaneously images fluorescence lifetimes in 3D with multiple excitation lasers. Through quantitative analysis of triple-channel intensity and lifetime images, we demonstrated that Ca2+ and cAMP levels of live embryos expressing dual FRET sensors can be monitored simultaneously at microscopic resolution. The method is compatible with a broad range of FRET sensors currently available for probing various cellular biochemical functions. It opens the door to imaging complex cellular circuitries in whole live organisms. PMID:26387920

  2. The simultaneous quantitation of ten amino acids in soil extracts by mass fragmentography

    NASA Technical Reports Server (NTRS)

    Pereira, W. E.; Hoyano, Y.; Reynolds, W. E.; Summons, R. E.; Duffield, A. M.

    1972-01-01

    A specific and sensitive method for the identification and simultaneous quantitation by mass fragmentography of ten of the amino acids present in soil was developed. The technique uses a computer driven quadrupole mass spectrometer and a commercial preparation of deuterated amino acids is used as internal standards for purposes of quantitation. The results obtained are comparable with those from an amino acid analyzer. In the quadrupole mass spectrometer-computer system up to 25 pre-selected ions may be monitored sequentially. This allows a maximum of 12 different amino acids (one specific ion in each of the undeuterated and deuterated amino acid spectra) to be quantitated. The method is relatively rapid (analysis time of approximately one hour) and is capable of the quantitation of nanogram quantities of amino acids.

  3. Simultaneous 19F-1H medium resolution NMR spectroscopy for online reaction monitoring

    NASA Astrophysics Data System (ADS)

    Zientek, Nicolai; Laurain, Clément; Meyer, Klas; Kraume, Matthias; Guthausen, Gisela; Maiwald, Michael

    2014-12-01

    Medium resolution nuclear magnetic resonance (MR-NMR) spectroscopy is currently a fast developing field, which has an enormous potential to become an important analytical tool for reaction monitoring, in hyphenated techniques, and for systematic investigations of complex mixtures. The recent developments of innovative MR-NMR spectrometers are therefore remarkable due to their possible applications in quality control, education, and process monitoring. MR-NMR spectroscopy can beneficially be applied for fast, non-invasive, and volume integrating analyses under rough environmental conditions. Within this study, a simple 1/16″ fluorinated ethylene propylene (FEP) tube with an ID of 0.04″ (1.02 mm) was used as a flow cell in combination with a 5 mm glass Dewar tube inserted into a benchtop MR-NMR spectrometer with a 1H Larmor frequency of 43.32 MHz and 40.68 MHz for 19F. For the first time, quasi-simultaneous proton and fluorine NMR spectra were recorded with a series of alternating 19F and 1H single scan spectra along the reaction time coordinate of a homogeneously catalysed esterification model reaction containing fluorinated compounds. The results were compared to quantitative NMR spectra from a hyphenated 500 MHz online NMR instrument for validation. Automation of handling, pre-processing, and analysis of NMR data becomes increasingly important for process monitoring applications of online NMR spectroscopy and for its technical and practical acceptance. Thus, NMR spectra were automatically baseline corrected and phased using the minimum entropy method. Data analysis schemes were designed such that they are based on simple direct integration or first principle line fitting, with the aim that the analysis directly revealed molar concentrations from the spectra. Finally, the performance of 1/16″ FEP tube set-up with an ID of 1.02 mm was characterised regarding the limit of detection (LOQ (1H) = 0.335 mol L-1 and LOQ (19F) = 0.130 mol L-1 for trifluoroethanol in D2O (single scan)) and maximum quantitative flow rates up to 0.3 mL min-1. Thus, a series of single scan 19F and 1H NMR spectra acquired with this simple set-up already presents a valuable basis for quantitative reaction monitoring.

  4. Quantitative determination of major active components in Ginkgo biloba dietary supplements by liquid chromatography/mass spectrometry.

    PubMed

    Ding, Shujing; Dudley, Ed; Plummer, Sue; Tang, Jiandong; Newton, Russell P; Brenton, A Gareth

    2006-01-01

    A reversed-phase high-performance liquid chromatography/electrospray ionisation mass spectrometry (RP-HPLC/ESI-MS) method was developed and validated for the simultaneous determination of ten major active components in Ginkgo biloba extract (bilobalide, ginkgolides A, B, C, quercetin, kaempferol, isorhamnetin, rutin hydrate, quercetin-3-beta-D-glucoside and quercitrin hydrate) which have not been previously reported to be quantified in a single analysis. The ten components exhibit baseline separation in 50 min by C18 chromatography using a water/1:1 (v/v) methanol/acetonitrile gradient. Quantitation was performed using negative ESI-MS in selected ion monitoring (SIM) mode. Good reproducibility and recovery were obtained by this method. The sensitivity of both UV and different mass spectrometry modes (full scan, selected ion monitoring (SIM), and selected reaction monitoring (SRM)) were compared and both quantitation with and without internal standard were evaluated. The analysis of Ginkgo biloba commercial products showed remarkable variations in the rutin and quercetin content as well as the terpene lactone contents although all the products satisfy the conventional quality control method. Copyright 2006 John Wiley & Sons, Ltd.

  5. A microfluidic device for real-time monitoring of Bacillus subtilis bacterial spores during germination based on non-specific physicochemical interactions on the nanoscale level.

    PubMed

    Zabrocka, L; Langer, K; Michalski, A; Kocik, J; Langer, J J

    2015-01-07

    A microfluidic device for studies on the germination of bacterial spores (e.g. Bacillus subtilis) based on non-specific interactions on the nanoscale is presented. A decrease in the population of spores during germination followed by the appearance of transition forms and an increase in the number of vegetative cells can be registered directly and simultaneously by using the microfluidic device, which is equipped with a conductive polymer layer (polyaniline) in the form of a nano-network. The lab-on-a-chip-type device, operating in a continuous flow regime, allows monitoring of germination of bacterial spores and analysis of the process in detail. The procedure is fast and accurate enough for quantitative real-time monitoring of the main steps of germination, including final transformation of the spores into vegetative cells. All of this is done without the use of biomarkers or any bio-specific materials, such as enzymes, antibodies and aptamers, and is simply based on an analysis of physicochemical interactions on the nanoscale level.

  6. Live single cell functional phenotyping in droplet nano-liter reactors.

    PubMed

    Konry, Tania; Golberg, Alexander; Yarmush, Martin

    2013-11-11

    While single cell heterogeneity is present in all biological systems, most studies cannot address it due to technical limitations. Here we describe a nano-liter droplet microfluidic-based approach for stimulation and monitoring of surface and secreted markers of live single immune dendritic cells (DCs) as well as monitoring the live T cell/DC interaction. This nano-liter in vivo simulating microenvironment allows delivering various stimuli reagents to each cell and appropriate gas exchanges which are necessary to ensure functionality and viability of encapsulated cells. Labeling bioassay and microsphere sensors were integrated into nano-liter reaction volume of the droplet to monitor live single cell surface markers and secretion analysis in the time-dependent fashion. Thus live cell stimulation, secretion and surface monitoring can be obtained simultaneously in distinct microenvironment, which previously was possible using complicated and multi-step in vitro and in vivo live-cell microscopy, together with immunological studies of the outcome secretion of cellular function.

  7. Different Spectrophotometric Methods for Simultaneous Determination of Trelagliptin and Its Acid Degradation Product

    PubMed Central

    Hassan, Mostafa A.; Zaghary, Wafaa A.

    2018-01-01

    New spectrophotometric and chemometric methods were carried out for the simultaneous assay of trelagliptin (TRG) and its acid degradation product (TAD) and applied successfully as a stability indicating assay to recently approved Zafatek® tablets. TAD was monitored using TLC to ensure complete degradation. Furthermore, HPLC was used to confirm dealing with one major acid degradation product. The proposed methods were developed by manipulating zero-order, first-derivative, and ratio spectra of TRG and TAD using simultaneous equation, first-derivative, and mean-centering methods, respectively. Using Spectra Manager II and Minitab v.14 software, the absorbance at 274 nm–260.4 nm, amplitudes at 260.4 nm–274.0 nm, and mean-centered values at 287.6 nm–257.2 nm were measured against methanol as a blank for TRG and TAD, respectively. Linearity and the other validation parameters were acceptable at concentration ranges of 5–50 μg/mL and 2.5–25 μg/mL for TRG and TAD, respectively. Using one-way analysis of variance (ANOVA), the optimized methods were compared and proved to be accurate for the simultaneous assay of TRG and TAD. PMID:29629213

  8. Different Spectrophotometric Methods for Simultaneous Determination of Trelagliptin and Its Acid Degradation Product.

    PubMed

    Mowaka, Shereen; Ayoub, Bassam M; Hassan, Mostafa A; Zaghary, Wafaa A

    2018-01-01

    New spectrophotometric and chemometric methods were carried out for the simultaneous assay of trelagliptin (TRG) and its acid degradation product (TAD) and applied successfully as a stability indicating assay to recently approved Zafatek® tablets. TAD was monitored using TLC to ensure complete degradation. Furthermore, HPLC was used to confirm dealing with one major acid degradation product. The proposed methods were developed by manipulating zero-order, first-derivative, and ratio spectra of TRG and TAD using simultaneous equation, first-derivative, and mean-centering methods, respectively. Using Spectra Manager II and Minitab v.14 software, the absorbance at 274 nm-260.4 nm, amplitudes at 260.4 nm-274.0 nm, and mean-centered values at 287.6 nm-257.2 nm were measured against methanol as a blank for TRG and TAD, respectively. Linearity and the other validation parameters were acceptable at concentration ranges of 5-50  μ g/mL and 2.5-25  μ g/mL for TRG and TAD, respectively. Using one-way analysis of variance (ANOVA), the optimized methods were compared and proved to be accurate for the simultaneous assay of TRG and TAD.

  9. A novel multiplex PCR assay for simultaneous detection of nine clinically significant bacterial pathogens associated with bovine mastitis.

    PubMed

    Ashraf, Aqeela; Imran, Muhammad; Yaqub, Tahir; Tayyab, Muhammad; Shehzad, Wasim; Thomson, Peter C

    2017-06-01

    For rapid and simultaneous detection of nine bovine mastitic pathogens, a sensitive and specific multiplex PCR assay was developed. The assay was standardized using reference strains and validated on mastitic milk cultures which were identified to species level based on 16S rRNA sequencing. Multiplex PCR assay also efficiently detected the target bacterial strains directly from milk. The detection limit of the assay was up to 50 pg for DNA isolated from pure cultures and 10 4  CFU/ml for spiked milk samples. As estimated by latent class analysis, the assay was sensitive up to 88% and specific up to 98% for targeted mastitic pathogens, compared with the bacterial culture method and the 16S rRNA sequence analysis. This novel molecular assay could be useful for monitoring and maintaining the bovine udder health, ensuring the bacteriological safety of milk, and conducting epidemiological studies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. 40 CFR 63.2161 - What performance tests and other procedures must I use if I monitor brew ethanol?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... procedures must I use if I monitor brew ethanol? 63.2161 Section 63.2161 Protection of Environment... performance tests and other procedures must I use if I monitor brew ethanol? (a) You must conduct each... performance test simultaneously with brew ethanol monitoring to establish a brew-to-exhaust correlation...

  11. 40 CFR 63.2161 - What performance tests and other procedures must I use if I monitor brew ethanol?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... procedures must I use if I monitor brew ethanol? 63.2161 Section 63.2161 Protection of Environment... performance tests and other procedures must I use if I monitor brew ethanol? (a) You must conduct each... performance test simultaneously with brew ethanol monitoring to establish a brew-to-exhaust correlation...

  12. 40 CFR 63.2161 - What performance tests and other procedures must I use if I monitor brew ethanol?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... procedures must I use if I monitor brew ethanol? 63.2161 Section 63.2161 Protection of Environment... performance tests and other procedures must I use if I monitor brew ethanol? (a) You must conduct each... performance test simultaneously with brew ethanol monitoring to establish a brew-to-exhaust correlation...

  13. Real-time monitoring implementation in a remote-pumped WDM PON

    NASA Astrophysics Data System (ADS)

    Liaw, S.-K.; Hong, K.-L.; Shei, Y.-S.

    2008-08-01

    We report on an improved configuration to monitor a passive optical network with high quality in service. This proposed system comprises fiber-Bragg gratings, a 1 × 4 optical switch, and an optical time-domain reflectometry to diagnose the broken point in real time. It could simultaneously detect multioptical network units in a WDM PON. The remote-pump integrated residual pumping reused function is implemented. Broken points in different optical paths can be detected simultaneously even when the distances to the central office are identical. The bit-error rate testing is verified with a small power penalty, making it an ideal solution for the real-time monitoring in a WDM PON.

  14. Citizen Science Air Monitor (CSAM) Operating Procedures

    EPA Science Inventory

    The Citizen Science Air Monitor (CSAM) is an air monitoring system designed for measuring nitrogen dioxide (NO2) and particulate matter (PM) pollutants simultaneously. This self-contained system consists of a CairPol CairClip NO2 sensor, a Thermo Scientific personal DataRAM PM2.5...

  15. SHARD - a SeisComP3 module for Structural Health Monitoring

    NASA Astrophysics Data System (ADS)

    Weber, B.; Becker, J.; Ellguth, E.; Henneberger, R.; Herrnkind, S.; Roessler, D.

    2016-12-01

    Monitoring building and structure response to strong earthquake ground shaking or human-induced vibrations in real-time forms the backbone of modern structural health monitoring (SHM). The continuous data transmission, processing and analysis reduces drastically the time decision makers need to plan for appropriate response to possible damages of high-priority buildings and structures. SHARD is a web browser based module using the SeisComp3 framework to monitor the structural health of buildings and other structures by calculating standard engineering seismology parameters and checking their exceedance in real-time. Thresholds can be defined, e.g. compliant with national building codes (IBC2000, DIN4149 or EC8), for PGA/PGV/PGD, response spectra and drift ratios. In case thresholds are exceeded automatic or operator driven reports are generated and send to the decision makers. SHARD also determines waveform quality in terms of data delay and variance to report sensor status. SHARD is the perfect tool for civil protection to monitor simultaneously multiple city-wide critical infrastructure as hospitals, schools, governmental buildings and structures as bridges, dams and power substations.

  16. Residual gas analysis for long-pulse, advanced tokamak operation.

    PubMed

    Klepper, C C; Hillis, D L; Bucalossi, J; Douai, D; Oddon, P; Vartanian, S; Colas, L; Manenc, L; Pégourié, B

    2010-10-01

    A shielded residual gas analyzer (RGA) system on Tore Supra can function during plasma operation and is set up to monitor the composition of the neutral gas in one of the pumping ducts of the toroidal pumped limited. This "diagnostic RGA" has been used in long-pulse (up to 6 min) discharges for continuous monitoring of up to 15 masses simultaneously. Comparison of the RGA-measured evolution of the H(2)/D(2) isotopic ratio in the exhaust gas to that measured by an energetic neutral particle analyzer in the plasma core provides a way to monitor the evolution of particle balance. RGA monitoring of corrective H(2) injection to maintain proper minority heating is providing a database for improved ion cyclotron resonance heating, potentially with RGA-base feedback control. In very long pulses (>4 min) absence of significant changes in the RGA-monitored, hydrocarbon particle pressures is an indication of proper operation of the actively cooled, carbon-based plasma facing components. Also H(2) could increase due to thermodesorption of overheated plasma facing components.

  17. Metabolic cytometry: capillary electrophoresis with two-color fluorescence detection for the simultaneous study of two glycosphingolipid metabolic pathways in single primary neurons.

    PubMed

    Essaka, David C; Prendergast, Jillian; Keithley, Richard B; Palcic, Monica M; Hindsgaul, Ole; Schnaar, Ronald L; Dovichi, Norman J

    2012-03-20

    Metabolic cytometry is a form of chemical cytometry wherein metabolic cascades are monitored in single cells. We report the first example of metabolic cytometry where two different metabolic pathways are simultaneously monitored. Glycolipid catabolism in primary rat cerebella neurons was probed by incubation with tetramethylrhodamine-labeled GM1 (GM1-TMR). Simultaneously, both catabolism and anabolism were probed by coincubation with BODIPY-FL labeled LacCer (LacCer-BODIPY-FL). In a metabolic cytometry experiment, single cells were incubated with substrate, washed, aspirated into a capillary, and lysed. The components were separated by capillary electrophoresis equipped with a two-spectral channel laser-induced fluorescence detector. One channel monitored fluorescence generated by the metabolic products produced from GM1-TMR and the other monitored the metabolic products produced from LacCer-BODIPY-FL. The metabolic products were identified by comparison with the mobility of a set of standards. The detection system produced at least 6 orders of magnitude dynamic range in each spectral channel with negligible spectral crosstalk. Detection limits were 1 zmol for BODIPY-FL and 500 ymol for tetramethylrhodamine standard solutions.

  18. MRM for the verification of cancer biomarker proteins: recent applications to human plasma and serum.

    PubMed

    Chambers, Andrew G; Percy, Andrew J; Simon, Romain; Borchers, Christoph H

    2014-04-01

    Accurate cancer biomarkers are needed for early detection, disease classification, prediction of therapeutic response and monitoring treatment. While there appears to be no shortage of candidate biomarker proteins, a major bottleneck in the biomarker pipeline continues to be their verification by enzyme linked immunosorbent assays. Multiple reaction monitoring (MRM), also known as selected reaction monitoring, is a targeted mass spectrometry approach to protein quantitation and is emerging to bridge the gap between biomarker discovery and clinical validation. Highly multiplexed MRM assays are readily configured and enable simultaneous verification of large numbers of candidates facilitating the development of biomarker panels which can increase specificity. This review focuses on recent applications of MRM to the analysis of plasma and serum from cancer patients for biomarker verification. The current status of this approach is discussed along with future directions for targeted mass spectrometry in clinical biomarker validation.

  19. Reflectance-mode interferometric near-infrared spectroscopy quantifies brain absorption, scattering, and blood flow index in vivo.

    PubMed

    Borycki, Dawid; Kholiqov, Oybek; Srinivasan, Vivek J

    2017-02-01

    Interferometric near-infrared spectroscopy (iNIRS) is a new technique that measures time-of-flight- (TOF-) resolved autocorrelations in turbid media, enabling simultaneous estimation of optical and dynamical properties. Here, we demonstrate reflectance-mode iNIRS for noninvasive monitoring of a mouse brain in vivo. A method for more precise quantification with less static interference from superficial layers, based on separating static and dynamic components of the optical field autocorrelation, is presented. Absolute values of absorption, reduced scattering, and blood flow index (BFI) are measured, and changes in BFI and absorption are monitored during a hypercapnic challenge. Absorption changes from TOF-resolved iNIRS agree with absorption changes from continuous wave NIRS analysis, based on TOF-integrated light intensity changes, an effective path length, and the modified Beer-Lambert Law. Thus, iNIRS is a promising approach for quantitative and noninvasive monitoring of perfusion and optical properties in vivo.

  20. Combined micro-droplet and thin-film-assisted pre-concentration of lead traces for on-line monitoring using anodic stripping voltammetry.

    PubMed

    Belostotsky, Inessa; Gridin, Vladimir V; Schechter, Israel; Yarnitzky, Chaim N

    2003-02-01

    An improved analytical method for airborne lead traces is reported. It is based on using a Venturi scrubber sampling device for simultaneous thin-film stripping and droplet entrapment of aerosol influxes. At least threefold enhancement of the lead-trace pre-concentration is achieved. The sampled traces are analyzed by square-wave anodic stripping voltammetry. The method was tested by a series of pilot experiments. These were performed using contaminant-controlled air intakes. Reproducible calibration plots were obtained. The data were validated by traditional analysis using filter sampling. LODs are comparable with the conventional techniques. The method was successfully applied to on-line and in situ environmental monitoring of lead.

  1. Combined Volatolomics for Monitoring of Human Body Chemistry

    PubMed Central

    Broza, Yoav Y.; Zuri, Liat; Haick, Hossam

    2014-01-01

    Analysis of volatile organic compounds (VOCs) is a promising approach for non-invasive, fast and potentially inexpensive diagnostics. Here, we present a new methodology for profiling the body chemistry by using the volatile fraction of molecules in various body fluids. Using mass spectrometry and cross-reactive nanomaterial-based sensors array, we demonstrate that simultaneous VOC detection from breath and skin would provide complementary, non-correlated information of the body's volatile metabolites profile. Eventually with further wide population validation studies, such a methodology could provide more accurate monitoring of pathological changes compared to the information provided by a single body fluid. The qualitative and quantitative methods presented here offers a variety of options for novel mapping of the metabolic properties of complex organisms, including humans. PMID:24714440

  2. Combined volatolomics for monitoring of human body chemistry.

    PubMed

    Broza, Yoav Y; Zuri, Liat; Haick, Hossam

    2014-04-09

    Analysis of volatile organic compounds (VOCs) is a promising approach for non-invasive, fast and potentially inexpensive diagnostics. Here, we present a new methodology for profiling the body chemistry by using the volatile fraction of molecules in various body fluids. Using mass spectrometry and cross-reactive nanomaterial-based sensors array, we demonstrate that simultaneous VOC detection from breath and skin would provide complementary, non-correlated information of the body's volatile metabolites profile. Eventually with further wide population validation studies, such a methodology could provide more accurate monitoring of pathological changes compared to the information provided by a single body fluid. The qualitative and quantitative methods presented here offers a variety of options for novel mapping of the metabolic properties of complex organisms, including humans.

  3. Drug monitoring: simultaneous analysis of lamotrigine, oxcarbazepine, 10-hydroxycarbazepine, and zonisamide by HPLC-UV and a rapid GC method using a nitrogen-phosphorus detector for levetiracetam

    PubMed Central

    Greiner-Sosanko, Elizabeth; Giannoutsos, Spiros; Lower, Darla R.; Virji, Mohamed A.; Krasowski, Matthew D.

    2008-01-01

    A high-performance liquid chromatography (HPLC) assay using ultraviolet detection is described for the simultaneous measurement of the newer generation anti-epileptic medications lamotrigine, oxcarbazepine (parent drug and active metabolite 10-hydroxycarbazepine), and zonisamide. Detection of all four compounds can be done at 230 nm; however, there is a potential interference with zonisamide in patients on clonazepam therapy. Therefore, the method uses dual wavelength detection: 230 nm for oxcarbazepine and 10-hydroxycarbazepine and 270 nm for lamotrigine and zonisamide. In addition, a simple gas chromatography method using a nitrogen-phosphorus detector is described for measurement of levetiracetam, another of the recently approved anti-epileptic medications. For both methods, limits of quantitation, linearities, accuracies, and imprecisions cover the therapeutic range for drug monitoring of patients. A wide variety of clinical drugs, including other anti-epileptic drugs, do not interfere with these assays. These procedures would be of special interest to clinical laboratories, particularly due to the limited availability of immunoassays for newer generation anti-epileptic medications and that therapeutic uses of these drugs are expanding beyond epilepsy to other neurologic and psychiatric disorders. PMID:17988451

  4. Visual Task Demands and the Auditory Mismatch Negativity: An Empirical Study and a Meta-Analysis

    PubMed Central

    Wiens, Stefan; Szychowska, Malina; Nilsson, Mats E.

    2016-01-01

    Because the auditory system is particularly useful in monitoring the environment, previous research has examined whether task-irrelevant, auditory distracters are processed even if subjects focus their attention on visual stimuli. This research suggests that attentionally demanding visual tasks decrease the auditory mismatch negativity (MMN) to simultaneously presented auditory distractors. Because a recent behavioral study found that high visual perceptual load decreased detection sensitivity of simultaneous tones, we used a similar task (n = 28) to determine if high visual perceptual load would reduce the auditory MMN. Results suggested that perceptual load did not decrease the MMN. At face value, these nonsignificant findings may suggest that effects of perceptual load on the MMN are smaller than those of other demanding visual tasks. If so, effect sizes should differ systematically between the present and previous studies. We conducted a selective meta-analysis of published studies in which the MMN was derived from the EEG, the visual task demands were continuous and varied between high and low within the same task, and the task-irrelevant tones were presented in a typical oddball paradigm simultaneously with the visual stimuli. Because the meta-analysis suggested that the present (null) findings did not differ systematically from previous findings, the available evidence was combined. Results of this meta-analysis confirmed that demanding visual tasks reduce the MMN to auditory distracters. However, because the meta-analysis was based on small studies and because of the risk for publication biases, future studies should be preregistered with large samples (n > 150) to provide confirmatory evidence for the results of the present meta-analysis. These future studies should also use control conditions that reduce confounding effects of neural adaptation, and use load manipulations that are defined independently from their effects on the MMN. PMID:26741815

  5. Heterogeneous recurrence monitoring and control of nonlinear stochastic processes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Hui, E-mail: huiyang@usf.edu; Chen, Yun

    Recurrence is one of the most common phenomena in natural and engineering systems. Process monitoring of dynamic transitions in nonlinear and nonstationary systems is more concerned with aperiodic recurrences and recurrence variations. However, little has been done to investigate the heterogeneous recurrence variations and link with the objectives of process monitoring and anomaly detection. Notably, nonlinear recurrence methodologies are based on homogeneous recurrences, which treat all recurrence states in the same way as black dots, and non-recurrence is white in recurrence plots. Heterogeneous recurrences are more concerned about the variations of recurrence states in terms of state properties (e.g., valuesmore » and relative locations) and the evolving dynamics (e.g., sequential state transitions). This paper presents a novel approach of heterogeneous recurrence analysis that utilizes a new fractal representation to delineate heterogeneous recurrence states in multiple scales, including the recurrences of both single states and multi-state sequences. Further, we developed a new set of heterogeneous recurrence quantifiers that are extracted from fractal representation in the transformed space. To that end, we integrated multivariate statistical control charts with heterogeneous recurrence analysis to simultaneously monitor two or more related quantifiers. Experimental results on nonlinear stochastic processes show that the proposed approach not only captures heterogeneous recurrence patterns in the fractal representation but also effectively monitors the changes in the dynamics of a complex system.« less

  6. Simultaneous Authentication and Certification of Arms-Control Measurement Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MacArthur, Duncan W.; Hauck, Danielle K.; Thron, Jonathan L.

    2012-07-09

    Most arms-control-treaty-monitoring scenarios involve a host party that makes a declaration regarding its nuclear material or items and a monitoring party that verifies that declaration. A verification system developed for such a use needs to be trusted by both parties. The first concern, primarily from the host party's point of view, is that any sensitive information that is collected must be protected without interfering in the efficient operation of the facility being monitored. This concern is addressed in what can be termed a 'certification' process. The second concern, of particular interest to the monitoring party, is that it must bemore » possible to confirm the veracity of both the measurement system and the data produced by this measurement system. The monitoring party addresses these issues during an 'authentication' process. Addressing either one of these concerns independently is relatively straightforward. However, it is more difficult to simultaneously satisfy host party certification concerns and monitoring party authentication concerns. Typically, both parties will want the final access to the measurement system. We will describe an alternative approach that allows both parties to gain confidence simultaneously. This approach starts with (1) joint development of the measurement system followed by (2) host certification of several copies of the system and (3) random selection by the inspecting party of one copy to be use during the monitoring visit and one (or more) copy(s) to be returned to the inspecting party's facilities for (4) further hardware authentication; any remaining copies are stored under joint seal for use as spares. Following this process, the parties will jointly (5) perform functional testing on the selected measurement system and then (6) use this system during the monitoring visit. Steps (1) and (2) assure the host party as to the certification of whichever system is eventually used in the monitoring visit. Steps (1), (3), (4), and (5) increase the monitoring party's confidence in the authentication of the measurement system.« less

  7. Method and apparatus for simultaneously measuring temperature and pressure

    DOEpatents

    Hirschfeld, Tomas B.; Haugen, Gilbert R.

    1988-01-01

    Method and apparatus are provided for simultaneously measuring temperature and pressure in a class of crystalline materials having anisotropic thermal coefficients and having a coefficient of linear compression along the crystalline c-axis substantially the same as those perpendicular thereto. Temperature is determined by monitoring the fluorescence half life of a probe of such crystalline material, e.g., ruby. Pressure is determined by monitoring at least one other fluorescent property of the probe that depends on pressure and/or temperature, e.g., absolute fluorescent intensity or frequency shifts of fluorescent emission lines.

  8. Simultaneous probing of bulk liquid phase and catalytic gas-liquid-solid interface under working conditions using attenuated total reflection infrared spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meemken, Fabian; Müller, Philipp; Hungerbühler, Konrad

    Design and performance of a reactor set-up for attenuated total reflection infrared (ATR-IR) spectroscopy suitable for simultaneous reaction monitoring of bulk liquid and catalytic solid-liquid-gas interfaces under working conditions are presented. As advancement of in situ spectroscopy an operando methodology for gas-liquid-solid reaction monitoring was developed that simultaneously combines catalytic activity and molecular level detection at the catalytically active site of the same sample. Semi-batch reactor conditions are achieved with the analytical set-up by implementing the ATR-IR flow-through cell in a recycle reactor system and integrating a specifically designed gas feeding system coupled with a bubble trap. By the usemore » of only one spectrometer the design of the new ATR-IR reactor cell allows for simultaneous detection of the bulk liquid and the catalytic interface during the working reaction. Holding two internal reflection elements (IRE) the sample compartments of the horizontally movable cell are consecutively flushed with reaction solution and pneumatically actuated, rapid switching of the cell (<1 s) enables to quasi simultaneously follow the heterogeneously catalysed reaction at the catalytic interface on a catalyst-coated IRE and in the bulk liquid on a blank IRE. For a complex heterogeneous reaction, the asymmetric hydrogenation of 2,2,2-trifluoroacetophenone on chirally modified Pt catalyst the elucidation of catalytic activity/enantioselectivity coupled with simultaneous monitoring of the catalytic solid-liquid-gas interface is shown. Both catalytic activity and enantioselectivity are strongly dependent on the experimental conditions. The opportunity to gain improved understanding by coupling measurements of catalytic performance and spectroscopic detection is presented. In addition, the applicability of modulation excitation spectroscopy and phase-sensitive detection are demonstrated.« less

  9. Spectrally Resolved Fiber Photometry for Multi-component Analysis of Brain Circuits.

    PubMed

    Meng, Chengbo; Zhou, Jingheng; Papaneri, Amy; Peddada, Teja; Xu, Karen; Cui, Guohong

    2018-04-25

    To achieve simultaneous measurement of multiple cellular events in molecularly defined groups of neurons in vivo, we designed a spectrometer-based fiber photometry system that allows for spectral unmixing of multiple fluorescence signals recorded from deep brain structures in behaving animals. Using green and red Ca 2+ indicators differentially expressed in striatal direct- and indirect-pathway neurons, we were able to simultaneously monitor the neural activity in these two pathways in freely moving animals. We found that the activities were highly synchronized between the direct and indirect pathways within one hemisphere and were desynchronized between the two hemispheres. We further analyzed the relationship between the movement patterns and the magnitude of activation in direct- and indirect-pathway neurons and found that the striatal direct and indirect pathways coordinately control the dynamics and fate of movement. Published by Elsevier Inc.

  10. The life sciences mass spectrometry research unit.

    PubMed

    Hopfgartner, Gérard; Varesio, Emmanuel

    2012-01-01

    The Life Sciences Mass Spectrometry (LSMS) research unit focuses on the development of novel analytical workflows based on innovative mass spectrometric and software tools for the analysis of low molecular weight compounds, peptides and proteins in complex biological matrices. The present article summarizes some of the recent work of the unit: i) the application of matrix-assisted laser desorption/ionization (MALDI) for mass spectrometry imaging (MSI) of drug of abuse in hair, ii) the use of high resolution mass spectrometry for simultaneous qualitative/quantitative analysis in drug metabolism and metabolomics, and iii) the absolute quantitation of proteins by mass spectrometry using the selected reaction monitoring mode.

  11. Method for Visually Integrating Multiple Data Acquisition Technologies for Real Time and Retrospective Analysis

    NASA Technical Reports Server (NTRS)

    Bogart, Edward H. (Inventor); Pope, Alan T. (Inventor)

    2000-01-01

    A system for display on a single video display terminal of multiple physiological measurements is provided. A subject is monitored by a plurality of instruments which feed data to a computer programmed to receive data, calculate data products such as index of engagement and heart rate, and display the data in a graphical format simultaneously on a single video display terminal. In addition live video representing the view of the subject and the experimental setup may also be integrated into the single data display. The display may be recorded on a standard video tape recorder for retrospective analysis.

  12. Simultaneous monitoring the real and imaginary parts of the analyte refractive index using liquid-core photonic bandgap Bragg fibers.

    PubMed

    Li, Jingwen; Qu, Hang; Skorobogatiy, Maksim

    2015-09-07

    We demonstrate simultaneous monitoring of the real and imaginary parts of the liquid analyte refractive index by using a hollow-core Bragg fiber. We apply this two-channel fiber sensor to monitor concentrations of various commercial cooling oils. The sensor operates using spectral monitoring of the fiber bandgap center wavelength, as well as monitoring of the fiber transmission amplitude at mid-bandgap position. The sensitivity of the fiber sensor to changes in the real part of the core refractive index is found to be 1460nm/Refractive index unit (RIU). By using spectral modality and effective medium theory, we determine the concentrations of the two commercial fluids from the measured refractive indices with an accuracy of ~0.57% for both low- and high-loss oils. Moreover, using an amplitude-based detection modality allows determination of the oil concentration with accuracy of ~1.64% for low-loss oils and ~2.81% for the high-loss oils.

  13. Simultaneous trilateral communication based on three mutually coupled chaotic semiconductor lasers with optical feedback.

    PubMed

    Li, Qiliang; Lu, Shanshan; Bao, Qi; Chen, Dewang; Hu, Miao; Zeng, Ran; Yang, Guowei; Li, Shuqin

    2018-01-10

    In this paper, we propose a chaos-based scheme allowing for trilateral communication among three mutually coupled chaotic semiconductor lasers. The coupling through a partially transparent optical mirror between two lasers induces the chaotic dynamics. We numerically solve the delay rate equations of three lasers and demonstrate that the dynamics is completely synchronous. Herein, each laser is not only a transmitter but a receiver; three different messages are encoded by simultaneously modulating bias current of the three lasers. By monitoring the synchronization error between transmitter and receiver, and comparing the error with the message of the local laser, we can decipher the message of the sender. The investigation indicates that these messages introduced on the two ends of each link among three lasers can be simultaneously transmitted and restored, so the system can realize simultaneous trilateral communication. In this scheme, an eavesdropper can monitor the synchronization error, but one has no way to obtain the bits that are being sent, so the trilateral communication is secure.

  14. Measurement of atmospheric mercury species with manual sampling and analysis methods in a case study in Indiana

    USGS Publications Warehouse

    Risch, M.R.; Prestbo, E.M.; Hawkins, L.

    2007-01-01

    Ground-level concentrations of three atmospheric mercury species were measured using manual sampling and analysis to provide data for estimates of mercury dry deposition. Three monitoring stations were operated simultaneously during winter, spring, and summer 2004, adjacent to three mercury wet-deposition monitoring stations in northern, central, and southern Indiana. The monitoring locations differed in land-use setting and annual mercury-emissions level from nearby sources. A timer-controlled air-sampling system that contained a three-part sampling train was used to isolate reactive gaseous mercury, particulate-bound mercury, and elemental mercury. The sampling trains were exchanged every 6 days, and the mercury species were quantified in a laboratory. A quality-assurance study indicated the sampling trains could be held at least 120 h without a significant change in reactive gaseous or particulate-bound mercury concentrations. The manual sampling method was able to provide valid mercury concentrations in 90 to 95% of samples. Statistical differences in mercury concentrations were observed during the project. Concentrations of reactive gaseous and elemental mercury were higher in the daytime samples than in the nighttime samples. Concentrations of reactive gaseous mercury were higher in winter than in summer and were highest at the urban monitoring location. The results of this case study indicated manual sampling and analysis could be a reliable method for measurement of atmospheric mercury species and has the capability for supplying representative concentrations in an effective manner from a long-term deposition-monitoring network. ?? 2007 Springer Science+Business Media B.V.

  15. Display/control requirements for automated VTOL aircraft

    NASA Technical Reports Server (NTRS)

    Hoffman, W. C.; Kleinman, D. L.; Young, L. R.

    1976-01-01

    A systematic design methodology for pilot displays in advanced commercial VTOL aircraft was developed and refined. The analyst is provided with a step-by-step procedure for conducting conceptual display/control configurations evaluations for simultaneous monitoring and control pilot tasks. The approach consists of three phases: formulation of information requirements, configuration evaluation, and system selection. Both the monitoring and control performance models are based upon the optimal control model of the human operator. Extensions to the conventional optimal control model required in the display design methodology include explicit optimization of control/monitoring attention; simultaneous monitoring and control performance predictions; and indifference threshold effects. The methodology was applied to NASA's experimental CH-47 helicopter in support of the VALT program. The CH-47 application examined the system performance of six flight conditions. Four candidate configurations are suggested for evaluation in pilot-in-the-loop simulations and eventual flight tests.

  16. Simultaneous analysis of the enantiomers of verapamil and norverapamil in rat plasma by liquid chromatography-tandem mass spectrometry.

    PubMed

    Mateus, Fabiano Henrique; Lepera, José Salvador; Marques, Maria Paula; Boralli, Vanessa Bergamin; Lanchote, Vera Lucia

    2007-12-21

    An enantioselective micromethod for the simultaneous analysis of verapamil (VER) and norverapamil (NOR) in plasma was developed, validated and applied to the study of the kinetic disposition of VER and NOR after the administration of a single oral dose of racemic-VER to rats. VER, NOR and the internal standard (paroxetine) were extracted from only 100-microL plasma samples using n-hexane and the enantiomers were resolved on a Chiralpak AD column using n-hexane:isopropanol:ethanol:diethylamine (88:6:6:0.1) as the mobile phase. The analyses were performed in the selected reaction monitoring mode. Transitions 456>166 for VER enantiomers, 441>166 for NOR enantiomers and 330>193 for the internal standard were monitored and the method had a total chromatographic run time of 12 min. The method allows the determination of VER and NOR enantiomers at plasma levels as low as 1.0 ng/mL. Racemic VER hydrochloride (10mg/kg) was given to male Wistar rats by gavage and blood samples were collected from 0 to 6.0 h (n=6 at each time point). The concentration of (-)-(S)-VER was three folds higher than (+)-(R)-VER, with an AUC ratio (-)/(+) of 2.66. Oral clearance values were 12.17 and 28.77 L/h/kg for (-)-(S)-VER and (+)-(R)-VER, respectively. The pharmacokinetic parameters of NOR were not shown to be enantioselective.

  17. Toward the development of Raman spectroscopy as a nonperturbative online monitoring tool for gasoline adulteration.

    PubMed

    Tan, Khay M; Barman, Ishan; Dingari, Narahara C; Singh, Gajendra P; Chia, Tet F; Tok, Wee L

    2013-02-05

    There is a critical need for a real-time, nonperturbative probe for monitoring the adulteration of automotive gasoline. Running on adulterated fuel leads to a substantive increase in air pollution, because of increased tailpipe emissions of harmful pollutants, as well as a reduction in engine performance. Consequently, both classification of the gasoline type and quantification of the adulteration content are of great significance for quality control. Gasoline adulteration detection is currently carried out in the laboratory with gas chromatography, which is time-consuming and costly. Here, we propose the application of Raman spectroscopic measurements for on-site rapid detection of gasoline adulteration. In this proof-of-principle report, we demonstrate the effectiveness of Raman spectra, in conjunction with multivariate analysis methods, in classifying the base oil types and simultaneously detecting the adulteration content in a wide range of commercial gasoline mixtures, both in their native states and spiked with different adulterants. In particular, we show that Raman spectra acquired with an inexpensive noncooled detector provides adequate specificity to clearly discriminate between the gasoline samples and simultaneously characterize the specific adulterant content with a limit of detection below 5%. Our promising results in this study illustrate, for the first time, the capability and the potential of Raman spectroscopy, together with multivariate analysis, as a low-cost, powerful tool for on-site rapid detection of gasoline adulteration and opens substantive avenues for applications in related fields of quality control in the oil industry.

  18. Simultaneous atmospheric nitrous oxide, methane and water vapor detection with a single continuous wave quantum cascade laser.

    PubMed

    Cao, Yingchun; Sanchez, Nancy P; Jiang, Wenzhe; Griffin, Robert J; Xie, Feng; Hughes, Lawrence C; Zah, Chung-en; Tittel, Frank K

    2015-02-09

    A continuous wave (CW) quantum cascade laser (QCL) based absorption sensor system was demonstrated and developed for simultaneous detection of atmospheric nitrous oxide (N(2)O), methane (CH(4)), and water vapor (H(2)O). A 7.73-µm CW QCL with its wavelength scanned over a spectral range of 1296.9-1297.6 cm(-1) was used to simultaneously target three neighboring strong absorption lines, N(2)O at 1297.05 cm(-1), CH(4) at 1297.486 cm(-1), and H(2)O at 1297.184 cm(-1). An astigmatic multipass Herriott cell with a 76-m path length was utilized for laser based gas absorption spectroscopy at an optimum pressure of 100 Torr. Wavelength modulation and second harmonic detection was employed for data processing. Minimum detection limits (MDLs) of 1.7 ppb for N(2)O, 8.5 ppb for CH(4), and 11 ppm for H(2)O were achieved with a 2-s integration time for individual gas detection. This single QCL based multi-gas detection system possesses applications in environmental monitoring and breath analysis.

  19. Dynamic data filtering system and method

    DOEpatents

    Bickford, Randall L; Palnitkar, Rahul M

    2014-04-29

    A computer-implemented dynamic data filtering system and method for selectively choosing operating data of a monitored asset that modifies or expands a learned scope of an empirical model of normal operation of the monitored asset while simultaneously rejecting operating data of the monitored asset that is indicative of excessive degradation or impending failure of the monitored asset, and utilizing the selectively chosen data for adaptively recalibrating the empirical model to more accurately monitor asset aging changes or operating condition changes of the monitored asset.

  20. Multisensor Capacitance Probes for Simultaneously Monitoring Rice Field Soil-Water- Crop-Ambient Conditions.

    PubMed

    Brinkhoff, James; Hornbuckle, John; Dowling, Thomas

    2017-12-26

    Multisensor capacitance probes (MCPs) have traditionally been used for soil moisture monitoring and irrigation scheduling. This paper presents a new application of these probes, namely the simultaneous monitoring of ponded water level, soil moisture, and temperature profile, conditions which are particularly important for rice crops in temperate growing regions and for rice grown with prolonged periods of drying. WiFi-based loggers are used to concurrently collect the data from the MCPs and ultrasonic distance sensors (giving an independent reading of water depth). Models are fit to MCP water depth vs volumetric water content (VWC) characteristics from laboratory measurements, variability from probe-to-probe is assessed, and the methodology is verified using measurements from a rice field throughout a growing season. The root-mean-squared error of the water depth calculated from MCP VWC over the rice growing season was 6.6 mm. MCPs are used to simultaneously monitor ponded water depth, soil moisture content when ponded water is drained, and temperatures in root, water, crop and ambient zones. The insulation effect of ponded water against cold-temperature effects is demonstrated with low and high water levels. The developed approach offers advantages in gaining the full soil-plant-atmosphere continuum in a single robust sensor.

  1. Near Infrared Spectroscopy for On-line Monitoring of Alkali- Free Cloth/Phenolic Resin Prepreg During Manufacture

    PubMed Central

    Jiang, Bo; Huang, Yu Dong

    2007-01-01

    A NIR method was developed for the on-line monitoring of alkali-free cloth/phenolic resin prepreg during its manufacturing process. First, the sizing content of the alkali-free cloth was analyzed, and then the resin, soluble resin and volatiles content of the prepreg was analyzed simultaneously using the FT-NIR spectrometer. Partial least square (PLS) regression was used to develop the calibration models, which for the sizing content was preprocessed by 1stDER +MSC, for the volatile content by 1stDER +VN, for the soluble resin content by 1stDER +MSC and for the resin content by the VN spectral data preprocessing method. RMSEP of the prediction model for the sizing content was 0.732 %, for the resin content it was 0.605, for the soluble resin content it was 0.101 and for volatiles content it was 0.127. The results of the paired t-test revealed that there was no significant difference between the NIR method and the standard method. The NIR spectroscopy method could be used to predict the resin, soluble resin and the volatiles content of the prepreg simultaneously, as well as sizing content of alkali-free cloth. The processing parameters of the prepreg during manufacture could be adjusted quickly with the help of the NIR analysis results. The results indicated that the NIR spectroscopy method was sufficiently accurate and effective for the on-line monitoring of alkali-free cloth/phenolic resin prepreg.

  2. Simultaneous life extension and crack monitoring of fatigue-damaged steel members using multifunctional carbon nanotube based composites

    NASA Astrophysics Data System (ADS)

    Ahmed, Shafique; Schumacher, Thomas; Thostenson, Erik T.; McConnell, Jennifer

    2017-04-01

    Steel structures including bridges are susceptible to cracking, particularly due to fatigue-sensitive details found in older designs. Therefore, one of the major challenges to keep those steel bridges in service is to rehabilitate existing and potential fatigue damage. There are several conventional approaches to extend the fatigue-life of damaged steel members, e.g., drilling a crack stop-hole to reduce the stress concentration at the crack tip as well as welding and bolting of steel plates or adhesive-bonding of fiber-reinforced polymers (FRP) to reduce the overall stresses. Improvement in material properties of FRP and adhesives make them a viable candidate to apply for extending the fatigue-life of steel members. However, drawbacks include the potential for debonding of the adhesive layer and/or interfaces between adhesive and adherents as well as difficulty in monitoring fatigue crack growth after rehabilitation. In this research, a holistic approach is proposed and evaluated for simultaneous extension of fatigue-life and monitoring by integrating a carbon nanotube (CNT)-based sensing layer with an adhesively-bonded FRP reinforcement. CNT-based sensing layers have a nerve-like electric resistance network, which enables distributed sensing capabilities to monitor stress levels, crack growth, and damage progression. Using laboratory-scale experiments, the simultaneous fatigue-life extension and crack monitoring capability of multifunctional CNT-based composites was evaluated. This paper introduces the fundamental concept of integrated fatigue-rehabilitation and monitoring of steel members, presents a laboratory-scale experiment to demonstrate the feasibility and effectiveness, and discusses challenges for implementation in real structures.

  3. Quantitative monitoring of two simultaneously binding species using Label-Enhanced surface plasmon resonance.

    PubMed

    Eng, Lars; Garcia, Brandon L; Geisbrecht, Brian V; Hanning, Anders

    2018-02-26

    Surface plasmon resonance (SPR) is a well-established method for biomolecular interaction studies. SPR monitors the binding of molecules to a solid surface, embodied as refractive index changes close to the surface. One limitation of conventional SPR is the universal nature of the detection that results in an inability to qualitatively discriminate between different binding species. Furthermore, it is impossible to directly discriminate two species simultaneously binding to different sites on a protein, which limits the utility of SPR, for example, in the study of allosteric binders or bi-specific molecules. It is also impossible in principle to discriminate protein conformation changes from actual binding events. Here we demonstrate how Label-Enhanced SPR can be utilized to discriminate and quantitatively monitor the simultaneous binding of two different species - one dye-labeled and one unlabeled - on a standard, single-wavelength SPR instrument. This new technique increases the versatility of SPR technology by opening up application areas where the usefulness of the approach has previously been limited. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. Titration of Alanine Monitored by NMR Spectroscopy: A Biochemistry Laboratory Experiment

    ERIC Educational Resources Information Center

    Waller, Francis J.; And Others

    1977-01-01

    The experiment described here involves simultaneous monitoring of pH and NMR chemical shifts during an aqueous titration of alpha- and beta-alanine. This experiment is designed for use in an undergraduate biochemistry course. (MR)

  5. Simultaneous determination of seven β-lactam antibiotics in human plasma for therapeutic drug monitoring and pharmacokinetic studies.

    PubMed

    Sime, Fekade Bruck; Roberts, Michael S; Roberts, Jason A; Robertson, Thomas A

    2014-06-01

    There is strong evidence in literature supporting the benefit of monitoring plasma concentrations of β-lactam antibiotics in the critically ill to ensure appropriateness of dosing. The objective of this work was to develop a method for the simultaneous determination of total concentrations piperacillin, benzylpenicillin, flucloxacillin, meropenem, ertapenem, cephazolin and ceftazidime in human plasma. Sample preparation involved protein precipitation with acetonitrile containing 0.1% formic acid and subsequent dilution of supernatant with 0.1% formic acid in water. Chromatographic separation was achieved on a reversed phase column (C18, 2.6 μm, 2.1 × 50 mm) via gradient elution using water and acetonitrile, each containing 0.1% formic acid, as mobile phase. Tandem mass spectrometry (MSMS) analysis was performed, after electrospray ionization in the positive mode, with multiple reaction monitoring (MRM). The method is accurate with the inter-day and intra-day accuracies of quality control samples (QCs) ranging from 95 to 107% and 95 to 108%, respectively. It is also precise with intra-day and inter-day coefficient of variations ranging from 4 to 12% and 5 to 14%, respectively. The lower limit of quantification was 0.1 μg/mL for each antibiotic except flucloxacillin (0.25 μg/mL). Recovery was greater than 96% for all analytes except for ertapenem (78%). Coefficients of variation for the matrix effect were less than 10% over the six batches of plasma. Analytes were stable over three freeze-thaw cycles, and for reasonable hours on the bench top as well as post-preparation. This novel liquid chromatography tandem mass spectrometry method proved accurate, precise and applicable for therapeutic drug monitoring and pharmacokinetic studies of the selected β-lactam antibiotics. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Fractionation of Oxygen Isotopes by Thermal Ionization Mass Spectrometry Inferred from Simultaneous Measurement of (17)O/(16)O and (18)O/(16)O Ratios and Implications for the (182)Hf-(182)W Systematics.

    PubMed

    Trinquier, Anne

    2016-06-07

    Accurate (182)Hf-(182)W chronology of early planetary differentiation relies on highly precise and accurate tungsten isotope measurements. WO3(-) analysis by negative thermal ionization mass spectrometry requires W(17)O(16)O2(-), W(17)O2(16)O(-), W(18)O(16)O2(-), W(17)O3(-), W(17)O(18)O(16)O(-), and W(18)O2(16)O(-) isotopologue interference corrections on W(16)O3(-) species ( Harper et al. Geochim. Cosmochim. Acta 1996 , 60 , 1131 ; Quitté et al. Geostandard. Newslett. 2002 , 26 , 149 ; Trinquier et al. Anal. Chem. 2016 , 88 , 1542 ; Touboul et al. Nature 2015 , 520 , 530 ; Touboul et al. Int. J. Mass Spectrom. 2012 , 309 , 109 ). In addition, low ion beam intensity counting statistics combined with Faraday cup detection noise limit the precision on the determination of (18)O/(16)O and (17)O/(16)O relative abundances. Mass dependent variability of (18)O/(16)O over the course of an analysis and between different analyses calls for oxide interference correction on a per integration basis, based on the in-run monitoring of the (18)O/(16)O ratio ( Harper et al. Geochim. Cosmochim. Acta 1996 , 60 , 1131 ; Quitté et al. Geostandard. Newslett. 2002 , 26 , 149 ; Trinquier et al. Anal. Chem. 2016 , 88 , 1542 ). Yet, the (17)O/(16)O variation is normally not being monitored and, instead, inferred from the measured (18)O/(16)O variation, assuming a δ(17)O-δ(18)O Terrestrial Fractionation Line ( Trinquier et al. Anal. Chem. 2016 , 88 , 1542 ). The purpose of the present study is to verify the validity of this assumption. Using high resistivity amplifiers, (238)U(17)O2 and (238)U(18)O2 ion beams down to 1.6 fA have been monitored simultaneously with (235,238)U(16)O2 species in a uranium certified reference material. This leads to a characterization of O isotope fractionation by thermal ionization mass spectrometry in variable loading and running conditions (additive-to-sample ratio, PO2 pressure, presence of ionized metal and oxide species). Proper determination of O isotope composition based on the simultaneous analysis of the (18)O/(16)O and (17)O/(16)O ratios could prevent tens of ppm bias or more on the (182)W/(184)W and (183)W/(184)W ratios.

  7. Simple and simultaneous determination of the hiv-protease inhibitors amprenavir, atazanavir, indinavir, lopinavir, nelfinavir, ritonavir and saquinavir plus M8 nelfinavir metabolite and the nonnucleoside reverse transcriptase inhibitors efavirenz and nevirapine in human plasma by reversed-phase liquid chromatography.

    PubMed

    Poirier, Jean-Marie; Robidou, Pascal; Jaillon, Patrice

    2005-04-01

    Several studies suggest that therapeutic drug monitoring of protease inhibitors and nonnucleoside reverse transcriptase inhibitors may contribute to the clinical outcome of HIV-infected patients. Because of the growing number of antiretroviral drugs and of drug combinations than can be administered to these patients, an accurate high-performance liquid chromatographic (HPLC) method allowing the simultaneous determination of these drugs may be useful. To date, the authors present the first simultaneous HPLC determination of the new protease inhibitor atazanavir with all the others currently in use (M8 nelfinavir metabolite included) and the 2 widely used nonnucleoside reverse transcriptase inhibitors efavirenz and nevirapine. This simple HPLC method allows the analysis all these drugs at a single ultraviolet wavelength following a 1-step liquid-liquid extraction procedure. A 500-muL plasma sample was spiked with internal standard and subjected to liquid-liquid extraction using by diethyl ether at pH 10. HPLC was performed using a Symmetry Shield RP18 and gradient elution. All the drugs of interest and internal standard were detected with ultraviolet detection at 210 nm. Calibration curves were linear in the range 50-10,000 ng/mL. The observed concentrations of the quality controls at plasma concentrations ranging from 50 to 5000 ng/mL for these drugs showed that the overall accuracy varied from 92% to 104% and 92% to 106% for intraday and day-to-day analysis, respectively. No metabolites of the assayed compounds or other drugs commonly coadministered to HIV-positive patients were found to coelute with the drugs of interest or with the internal standard. This assay was developed for the purpose of therapeutic monitoring (TDM) in HIV-infected patients.

  8. [Analysis of sulfonamids and their metabolites in drinking water by high Performance liquid chromatography tandem mass spectrometry].

    PubMed

    Wang, Shuo; Li, Shuming; Zhang, Xiangming; Wei, Yunfang; Zhang, Meiyun; Zhang, Jing

    2015-07-01

    To develop a comprehensive method for simultaneous analysis of sulfonamides and their metabolites in drinking water by high performance liquid chromatography tandem mass spectrometry (LC-MS/MS). Different solid-phase extraction columns were compared with respect to the recovery of target drugs from drinking water. The drinking water samples were adjusted to 3 by HCl and purified by a mix mode cation-ion exchange solid-phase extraction (SPE), following determination using LG-MS/MS. A total of 21 sulfonamides were separated by a C15 column (2.1 mm x 100 mm, 1.7 µm) and analyzed under positive ion mode with multi-reaction monitoring. The matrix-matched external standard calibration was used for quantification. The method quantification limits for 21 analytes were 0.03-0.63 ng/L with overall recoveries of 50.1%-114.9%, and the relative standard deviations less than 20%. The method was finally used to analyze sulfonamides in drinking water in Beijing, and 5 target compounds (sulfadiazine, sulfathiazole, sulfapyridine, trimethoprim and sulfamethazine) were detected at a concentration range of 0.08-32.54 ng/L. This method could be applied in simultaneous analysis of sulfonamides and their metabolites in drinking water samples.

  9. Simultaneous determination of sixteen metabolites related to neural tube defects in maternal serum by liquid chromatography coupling with electrospray tandem mass spectrometry.

    PubMed

    Liang, Xiao-Ping; Liang, Qiong-Lin; Xia, Jian-Fei; Wang, Yong; Hu, Ping; Wang, Yi-Ming; Zheng, Xiao-Ying; Zhang, Ting; Luo, Guo-An

    2009-06-15

    Disturbances in maternal folate, homocysteine, and glutathione metabolism have been reported to be associated with neural tube defects (NTDs). However, the role played by specific components in the metabolic pathways leading to NTDs remains unclear. Thus an analytical method for simultaneous measurement of sixteen compounds involved in such three metabolic pathways by high performance liquid chromatography-tandem mass spectrometry was developed. The use of hydrophilic chromatography column improved the separation of polar analytes and the detection mode of multiple-reaction monitoring (MRM) enhanced the specificity and sensitivity so as to achieve simultaneous determination of three class of metabolites which have much variance in polarity and contents. The influence of parameters such as temperature, pH, flow rate on the performance of the analytes were studied to get an optimal condition. The method was validated for its linearity, accuracy, and precision, and also used for the analysis of serum samples of NTDs-affected pregnancies and normal women. The result showed that the present method is sensitive and reliable for simultaneous determination of as many as sixteen interesting metabolites which may provide a new means to study the underlying mechanism of NTDs as well as to discover new potential biomarkers.

  10. Technical Report of Successful Deployment of Tandem Visual Tracking During Live Laparoscopic Cholecystectomy Between Novice and Expert Surgeon.

    PubMed

    Puckett, Yana; Baronia, Benedicto C

    2016-09-20

    With the recent advances in eye tracking technology, it is now possible to track surgeons' eye movements while engaged in a surgical task or when surgical residents practice their surgical skills. Several studies have compared eye movements of surgical experts and novices and developed techniques to assess surgical skill on the basis of eye movement utilizing simulators and live surgery. None have evaluated simultaneous visual tracking between an expert and a novice during live surgery. Here, we describe a successful simultaneous deployment of visual tracking of an expert and a novice during live laparoscopic cholecystectomy. One expert surgeon and one chief surgical resident at an accredited surgical program in Lubbock, TX, USA performed a live laparoscopic cholecystectomy while simultaneously wearing the visual tracking devices. Their visual attitudes and movements were monitored via video recordings. The recordings were then analyzed for correlation between the expert and the novice. The visual attitudes and movements correlated approximately 85% between an expert surgeon and a chief surgical resident. The surgery was carried out uneventfully, and the data was abstracted with ease. We conclude that simultaneous deployment of visual tracking during live laparoscopic surgery is a possibility. More studies and subjects are needed to verify the success of our results and obtain data analysis.

  11. EnvironmentalWaveletTool: Continuous and discrete wavelet analysis and filtering for environmental time series

    NASA Astrophysics Data System (ADS)

    Galiana-Merino, J. J.; Pla, C.; Fernandez-Cortes, A.; Cuezva, S.; Ortiz, J.; Benavente, D.

    2014-10-01

    A MATLAB-based computer code has been developed for the simultaneous wavelet analysis and filtering of several environmental time series, particularly focused on the analyses of cave monitoring data. The continuous wavelet transform, the discrete wavelet transform and the discrete wavelet packet transform have been implemented to provide a fast and precise time-period examination of the time series at different period bands. Moreover, statistic methods to examine the relation between two signals have been included. Finally, the entropy of curves and splines based methods have also been developed for segmenting and modeling the analyzed time series. All these methods together provide a user-friendly and fast program for the environmental signal analysis, with useful, practical and understandable results.

  12. Cavity-Enhanced Raman Spectroscopy for Food Chain Management

    PubMed Central

    Sandfort, Vincenz; Goldschmidt, Jens; Wöllenstein, Jürgen

    2018-01-01

    Comprehensive food chain management requires the monitoring of many parameters including temperature, humidity, and multiple gases. The latter is highly challenging because no low-cost technology for the simultaneous chemical analysis of multiple gaseous components currently exists. This contribution proposes the use of cavity enhanced Raman spectroscopy to enable online monitoring of all relevant components using a single laser source. A laboratory scale setup is presented and characterized in detail. Power enhancement of the pump light is achieved in an optical resonator with a Finesse exceeding 2500. A simulation for the light scattering behavior shows the influence of polarization on the spatial distribution of the Raman scattered light. The setup is also used to measure three relevant showcase gases to demonstrate the feasibility of the approach, including carbon dioxide, oxygen and ethene. PMID:29495501

  13. Mass Spectrometry in Clinical Laboratory: Applications in Therapeutic Drug Monitoring and Toxicology.

    PubMed

    Garg, Uttam; Zhang, Yan Victoria

    2016-01-01

    Mass spectrometry (MS) has been used in research and specialized clinical laboratories for decades as a very powerful technology to identify and quantify compounds. In recent years, application of MS in routine clinical laboratories has increased significantly. This is mainly due to the ability of MS to provide very specific identification, high sensitivity, and simultaneous analysis of multiple analytes (>100). The coupling of tandem mass spectrometry with gas chromatography (GC) or liquid chromatography (LC) has enabled the rapid expansion of this technology. While applications of MS are used in many clinical areas, therapeutic drug monitoring, drugs of abuse, and clinical toxicology are still the primary focuses of the field. It is not uncommon to see mass spectrometry being used in routine clinical practices for those applications.

  14. Ground-based measurements of ionospheric dynamics

    NASA Astrophysics Data System (ADS)

    Kouba, Daniel; Chum, Jaroslav

    2018-05-01

    Different methods are used to research and monitor the ionospheric dynamics using ground measurements: Digisonde Drift Measurements (DDM) and Continuous Doppler Sounding (CDS). For the first time, we present comparison between both methods on specific examples. Both methods provide information about the vertical drift velocity component. The DDM provides more information about the drift velocity vector and detected reflection points. However, the method is limited by the relatively low time resolution. In contrast, the strength of CDS is its high time resolution. The discussed methods can be used for real-time monitoring of medium scale travelling ionospheric disturbances. We conclude that it is advantageous to use both methods simultaneously if possible. The CDS is then applied for the disturbance detection and analysis, and the DDM is applied for the reflection height control.

  15. Development and Validation of a Practical Instrument for Injury Prevention: The Occupational Safety and Health Monitoring and Assessment Tool (OSH-MAT).

    PubMed

    Sun, Yi; Arning, Martin; Bochmann, Frank; Börger, Jutta; Heitmann, Thomas

    2018-06-01

    The Occupational Safety and Health Monitoring and Assessment Tool (OSH-MAT) is a practical instrument that is currently used in the German woodworking and metalworking industries to monitor safety conditions at workplaces. The 12-item scoring system has three subscales rating technical, organizational, and personnel-related conditions in a company. Each item has a rating value ranging from 1 to 9, with higher values indicating higher standard of safety conditions. The reliability of this instrument was evaluated in a cross-sectional survey among 128 companies and its validity among 30,514 companies. The inter-rater reliability of the instrument was examined independently and simultaneously by two well-trained safety engineers. Agreement between the double ratings was quantified by the intraclass correlation coefficient and absolute agreement of the rating values. The content validity of the OSH-MAT was evaluated by quantifying the association between OSH-MAT values and 5-year average injury rates by Poisson regression analysis adjusted for the size of the companies and industrial sectors. The construct validity of OSH-MAT was examined by principle component factor analysis. Our analysis indicated good to very good inter-rater reliability (intraclass correlation coefficient = 0.64-0.74) of OSH-MAT values with an absolute agreement of between 72% and 81%. Factor analysis identified three component subscales that met exactly the structure theory of this instrument. The Poisson regression analysis demonstrated a statistically significant exposure-response relationship between OSH-MAT values and the 5-year average injury rates. These analyses indicate that OSH-MAT is a valid and reliable instrument that can be used effectively to monitor safety conditions at workplaces.

  16. Simultaneous analysis of aminoglycosides with many other classes of drug residues in bovine tissues by ultrahigh-performance liquid chromatography-tandem mass spectrometry using an ion-pairing reagent added to final extracts.

    PubMed

    Lehotay, Steven J; Lightfield, Alan R

    2018-01-01

    The way to maximize scope of analysis, sample throughput, and laboratory efficiency in the monitoring of veterinary drug residues in food animals is to determine as many analytes as possible as fast as possible in as few methods as possible. Capital and overhead expenses are also reduced by using fewer instruments in the overall monitoring scheme. Traditionally, the highly polar aminoglycoside antibiotics require different chromatographic conditions from other classes of drugs, but in this work, we demonstrate that an ion-pairing reagent (sodium 1-heptanesulfonate) added to the combined final extracts from two sample preparation methods attains good separation of 174 targeted drugs, including 9 aminoglycosides, in the same 10.5-min ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) analysis. The full method was validated in bovine kidney, liver, and muscle tissues according to US regulatory protocols, and 137-146 (79-84%) of the drugs gave between 70 and 120% average recoveries with ≤ 25% RSDs in the different types of tissues spiked at 0.5, 1, and 2 times the regulatory levels of interest (10-1000 ng/g depending on the drug). This method increases sample throughput and the possible number of drugs monitored in the US National Residue Program, and requires only one UHPLC-MS/MS method and instrument for analysis rather than two by the previous scheme. Graphical abstract Outline of the streamlined approach to monitor 174 veterinary drugs, including aminoglycosides, in bovine tissues by combining two extracts of the same sample with an ion-pairing reagent for analysis by UHPLC-MS/MS.

  17. Development of a real-time radon monitoring system for simultaneous measurements in multiple sites

    NASA Astrophysics Data System (ADS)

    Yamamoto, S.; Yamasoto, K.; Iida, T.

    1999-12-01

    A real-time radon monitoring system that can simultaneously measure radon concentrations in multiple sites was developed and tested. The system consists of maximum of four radon detectors, optical fiber cables and a data acquisition personal computer. The radon detector uses a plastic scintillation counter that collects radon daughters in the chamber electrostatically. The applied voltage on the photocathode for the photomultiplier tube (PMT) acts as an electrode for radon daughters. The thickness of the plastic scintillator was thin, 50 /spl mu/m, so as to minimize the background counts due to the environmental gamma rays or beta particles. The energy discriminated signals from the radon detectors are fed to the data acquisition personal computer via optical fiber cables. The system made it possible to measure the radon concentrations in multiple sites simultaneously.

  18. Simultaneous Monitoring of Ballistocardiogram and Photoplethysmogram Using Camera

    PubMed Central

    Shao, Dangdang; Tsow, Francis; Liu, Chenbin; Yang, Yuting; Tao, Nongjian

    2017-01-01

    We present a noncontact method to measure Ballistocardiogram (BCG) and Photoplethysmogram (PPG) simultaneously using a single camera. The method tracks the motion of facial features to determine displacement BCG, and extracts the corresponding velocity and acceleration BCGs by taking first and second temporal derivatives from the displacement BCG, respectively. The measured BCG waveforms are consistent with those reported in literature and also with those recorded with an accelerometer-based reference method. The method also tracks PPG based on the reflected light from the same facial region, which makes it possible to track both BCG and PPG with the same optics. We verify the robustness and reproducibility of the noncontact method with a small pilot study with 23 subjects. The presented method is the first demonstration of simultaneous BCG and PPG monitoring without wearing any extra equipment or marker by the subject. PMID:27362754

  19. A Wearable Microfluidic Sensing Patch for Dynamic Sweat Secretion Analysis.

    PubMed

    Nyein, Hnin Yin Yin; Tai, Li-Chia; Ngo, Quynh Phuong; Chao, Minghan; Zhang, George B; Gao, Wei; Bariya, Mallika; Bullock, James; Kim, Hyungjin; Fahad, Hossain M; Javey, Ali

    2018-05-25

    Wearable sweat sensing is a rapidly rising research area driven by its promising potential in health, fitness, and diagnostic applications. Despite the growth in the field, major challenges in relation to sweat metrics remain to be addressed. These challenges include sweat rate monitoring for its complex relation with sweat compositions and sweat sampling for sweat dynamics studies. In this work, we present a flexible microfluidic sweat sensing patch that enhances real-time electrochemical sensing and sweat rate analysis via sweat sampling. The device contains a spiral-patterned microfluidic component that is embedded with ion-selective sensors and an electrical impedance-based sweat rate sensor on a flexible plastic substrate. The patch is enabled to autonomously perform sweat analysis by interfacing the sensing component with a printed circuit board that is capable of on-site signal conditioning, analysis, and transmission. Progressive sweat flow in the microfluidic device, governed by the pressure induced by the secreted sweat, enhances sweat sampling and electrochemical detection via a defined sweat collection chamber and a directed sweat route. The characteristic of the sweat rate sensor is validated through a theoretical simulation, and the precision and accuracy of the flow rate is verified with a commercial syringe pump and a Macroduct sweat collector. On-body simultaneous monitoring of ion (H + , Na + , K + , Cl - ) concentration and sweat rate is also demonstrated for sensor functionality. This sweat sensing patch provides an integrated platform for a comprehensive sweat secretion analysis and facilitates physiological and clinical investigations by closely monitoring interrelated sweat parameters.

  20. Monitoring the Black Hole Binary GRS 1758-258 with INTEGRAL and RXTE

    NASA Technical Reports Server (NTRS)

    Pottschmidt, Katja; Chernyakova, Masha; Lubinski, Piotr; Migliari, Simone; Smith, David M.; Zdziarski, Andrzej A.; Tomsick, John A.; Bezayiff, N.; Kreykenbohm, Ingo; Kretschmar, Peter; hide

    2008-01-01

    The microquasar GRS 1758-258 is one of only three persistent black hole binaries that spend most of their time in the hard spectral state, the other two being Cyg X-l and 1E 1741.7-2942. It therefore provides the rare opportunity for an extensive long term study of this important black hole state which is associated with strong variability and radio jet emission. INTEGRAL has been monitoring the source since the first Galactic Center Deep Exposure season in spring 2003 during two 2-3 months long Galactic Center viewing epochs each year, amounting to 11 epochs including spring of 2008. With the exception of the last epoch quasi-simultaneous RXTE monitoring observations are available as well. Here we present an analysis of the epoch averaged broad band spectra which display considerable long term variability, most notably the occurrence of two soft/off states, extreme examples for the hysteretic behavior of black hole binaries. The hard source spectrum and long exposures allow us to extend the analysis for several epochs to approximately 800 keV using PICsIT data and address the question of the presence of a non-thermal Comptonization component.

  1. Fast and simultaneous monitoring of organic pollutants in a drinking water treatment plant by a multi-analyte biosensor followed by LC-MS validation.

    PubMed

    Rodriguez-Mozaz, Sara; de Alda, Maria J López; Barceló, Damià

    2006-04-15

    This work describes the application of an optical biosensor (RIver ANALyser, RIANA) to the simultaneous analysis of three relevant environmental organic pollutants, namely, the pesticides atrazine and isoproturon and the estrogen estrone, in real water samples. This biosensor is based on an indirect inhibition immunoassay which takes place at a chemically modified optical transducer chip. The spatially resolved modification of the transducer surface allows the simultaneous determination of selected target analytes by means of "total internal reflection fluorescence" (TIRF). The performance of the immunosensor method developed was evaluated against a well accepted traditional method based on solid-phase extraction followed by liquid chromatography-mass spectrometry (LC-MS). The chromatographic method was superior in terms of linearity, sensitivity and accuracy, and the biosensor method in terms of repeatability, speed, cost and automation. The application of both methods in parallel to determine the occurrence and removal of atrazine, isoproturon and estrone throughout the treatment process (sand filtration, ozonation, activated carbon filtration and chlorination) in a waterworks showed an overestimation of results in the case of the biosensor, which was partially attributed to matrix and cross-reactivity effects, in spite of the addition of ovalbumin to the sample to minimize matrix interferences. Based on the comparative performance of both techniques, the biosensor emerges as a suitable tool for fast, simple and automated screening of water pollutants without sample pretreatment. To the author's knowledge, this is the first description of the application of the biosensor RIANA in the multi-analyte configuration to the regular monitoring of pollutants in a waterworks.

  2. Simultaneous analysis and monitoring of 16 UV filters in cosmetics by high-performance liquid chromatography.

    PubMed

    Kim, Dojung; Kim, Sangseop; Kim, Seol-A; Choi, Myoengsin; Kwon, Kyoung-Jin; Kim, Mijeong; Kim, Dong-Sup; Kim, Seung-Hee; Choi, Bo-Kyung

    2012-01-01

    Sixteen UV filters were simultaneously analyzed using the high-performance liquid chromatographic method. They were drometrizole (USAN Drometrizole), 4-methylbenzylidene camphor (USAN Enzacamene), menthyl anthranilate (USAN Menthyl anthranilate), benzophenone-3 (USAN Oxybenzone), benzophenone-8 (USAN Dioxybenzone), butyl methoxydibenzoylmethane (USAN Avobenzone), ethylhexyl triazone (USAN Octyl triazone), octocrylene (USAN Octocrylene), ethylhexyl dimethyl p-aminobenzoic acid (USAN Padimate O), ethylhexyl methoxycinnamate (USAN Octinoxate), p-aminobenzoic acid (USAN Aminobenzoic acid), 2-phenylbenzimidazole-5-sulfonic acid (USAN Ensulizole), isoamyl p-methoxycinnamate (USAN Amiloxate), and recent UV filters such as diethylhexyl butamidotriazone (USAN Iscotrizinol), methylene bis-benzotriazolyl tetramethylbutylphenol (USAN Bisoctrizole), and terephthalylidene dicamphor sulfonic acid (USAN Ecamsule). Separation of the UV filters was carried out in a C(18) column with a gradient of methanol-phosphate buffer, and the UV detection was at 300, 320, or 360 nm without any interference. The limits of detection were between 0.08 and 1.94 μg/ml, and the limits of quantitation were between 0.24 and 5.89 μg/ml. The extracting solvent for the UV filters was methanol, except for ethylhexyl triazone and methylene bis-benzotriazolyl tetramethylbutylphenol, which were prepared with tetrahydrofuran. The recoveries from spiked samples were between 94.90% and 116.54%, depending on the matrixes used. The developed method was applied to 23 sunscreens obtained from local markets, and the results were acceptable to their own criteria and to maximum authorized concentrations. Consequently, these results would provide a simple extracting method and a simultaneous determination for various UV filters, which can improve the quality control process as well as the environmental monitoring of sunscreens.

  3. An instrument for the simultaneous acquisition of size, shape, and spectral fluorescence data from single aerosol particles

    NASA Astrophysics Data System (ADS)

    Hirst, Edwin; Kaye, Paul H.; Foot, Virginia E.; Clark, James M.; Withers, Philip B.

    2004-12-01

    We describe the construction of a bio-aerosol monitor designed to capture and record intrinsic fluorescence spectra from individual aerosol particles carried in a sample airflow and to simultaneously capture data relating to the spatial distribution of elastically scattered light from each particle. The spectral fluorescence data recorded by this PFAS (Particle Fluorescence and Shape) monitor contains information relating to the particle material content and specifically to possible biological fluorophores. The spatial scattering data from PFAS yields information relating to particle size and shape. The combination of these data can provide a means of aiding the discrimination of bio-aerosols from background or interferent aerosol particles which may have similar fluorescence properties but exhibit shapes and/or sizes not normally associated with biological particles. The radiation used both to excite particle fluorescence and generate the necessary spatially scattered light flux is provided by a novel compact UV fiber laser operating at 266nm wavelength. Particles drawn from the ambient environment traverse the laser beam in single file. Intrinsic particle fluorescence in the range 300-570nm is collected via an ellipsoidal concentrator into a concave grating spectrometer, the spectral data being recorded using a 16-anode linear array photomultiplier detector. Simultaneously, the spatial radiation pattern scattered by the particle over 5°-30° scattering angle and 360° of azimuth is recorded using a custom designed 31-pixel radial hybrid photodiode array. Data from up to ~5,000 particles per second may be acquired for analysis, usually performed by artificial neural network classification.

  4. Simultaneous chromatic dispersion monitoring and optical modulation format identification utilizing four wave mixing

    NASA Astrophysics Data System (ADS)

    Cui, Sheng; Qiu, Chen; Ke, Changjian; He, Sheng; Liu, Deming

    2015-11-01

    This paper presents a method which is able to monitor the chromatic dispersion (CD) and identify the modulation format (MF) of optical signals simultaneously. This method utilizes the features of the output curve of the highly sensitive all-optical CD monitor based on four wave mixing (FWM). From the symmetric center of the curve CD can be estimated blindly and independently, while from the profile and convergence region of the curve ten commonly used modulation formats can be recognized with simple algorithm based on maximum correlation classifier. This technique does not need any high speed optoelectronics and has no limitation on signal rate. Furthermore it can tolerate large CD distortions and is robust to polarization mode dispersion (PMD) and amplified spontaneous emission (ASE) noise.

  5. SIMULTANEOUS B'V'R' MONITORING OF BL LACERTAE OBJECT S5 0716+714 AND DETECTION OF INTER-BAND TIME DELAY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu Jianghua; He Xiangtao; Boettcher, Markus

    We present the results of our optical monitoring of the BL Lac object S5 0716+714 over seven nights in 2006 December. The monitoring was carried out simultaneously at three optical wavelengths with a novel photometric system. The object did not show large-amplitude internight variations during this period. Intranight variations were observed on four nights and probably on one more. Strong bluer-when-brighter chromatism was detected on both intranight and internight timescales. The intranight variation amplitude decreases in the wavelength sequence of B', R', and V'. Cross-correlation analyses revealed that the variability at the B' and V' bands leads that at themore » R' band by about 30 minutes on one night.« less

  6. Five-Channel Infrared Laser Absorption Spectrometer for Combustion Product Monitoring Aboard Manned Spacecraft

    NASA Technical Reports Server (NTRS)

    Briggs, Ryan M.; Frez, Clifford; Borgentun, Carl E.; Bagheri, Mahmood; Forouhar, Siamak; May, Randy D.

    2014-01-01

    Continuous combustion product monitoring aboard manned spacecraft can prevent chronic exposure to hazardous compounds and also provides early detection of combustion events. As future missions extend beyond low-Earth orbit, analysis of returned environmental samples becomes impractical and safety monitoring should be performed in situ. Here, we describe initial designs of a five-channel tunable laser absorption spectrometer to continuously monitor combustion products with the goal of minimal maintenance and calibration over long-duration missions. The instrument incorporates dedicated laser channels to simultaneously target strong mid-infrared absorption lines of CO, HCl, HCN, HF, and CO2. The availability of low-power-consumption semiconductor lasers operating in the 2 to 5 micron wavelength range affords the flexibility to select absorption lines for each gas with maximum interaction strength and minimal interference from other gases, which enables the design of a compact and mechanically robust spectrometer with low-level sensitivity. In this paper, we focus primarily on absorption line selection based on the availability of low-power single-mode semiconductor laser sources designed specifically for the target wavelength range.

  7. Sensitive Quantification of Cannabinoids in Milk by Alkaline Saponification-Solid Phase Extraction Combined with Isotope Dilution UPLC-MS/MS.

    PubMed

    Wei, Binnian; McGuffey, James E; Blount, Benjamin C; Wang, Lanqing

    2016-01-01

    Maternal exposure to marijuana during the lactation period-either active or passive-has prompted concerns about transmission of cannabinoids to breastfed infants and possible subsequent adverse health consequences. Assessing these health risks requires a sensitive analytical approach that is able to quantitatively measure trace-level cannabinoids in breast milk. Here, we describe a saponification-solid phase extraction approach combined with ultra-high-pressure liquid chromatography-tandem mass spectrometry for simultaneously quantifying Δ9-tetrahydrocannabinol (THC), cannabidiol (CBD), and cannabinol (CBN) in breast milk. We demonstrate for the first time that constraints on sensitivity can be overcome by utilizing alkaline saponification of the milk samples. After extensively optimizing the saponification procedure, the validated method exhibited limits of detections of 13, 4, and 66 pg/mL for THC, CBN, and CBD, respectively. Notably, the sensitivity achieved was significantly improved, for instance, the limits of detection for THC is at least 100-fold more sensitive compared to that previously reported in the literature. This is essential for monitoring cannabinoids in breast milk resulting from passive or nonrecent active maternal exposure. Furthermore, we simultaneously acquired multiple reaction monitoring transitions for 12 C- and 13 C-analyte isotopes. This combined analysis largely facilitated data acquisition by reducing the repetitive analysis rate for samples exceeding the linear limits of 12 C-analytes. In addition to high sensitivity and broad quantitation range, this method delivers excellent accuracy (relative error within ±10%), precision (relative standard deviation <10%), and efficient analysis. In future studies, we expect this method to play a critical role in assessing infant exposure to cannabinoids through breastfeeding.

  8. Development of a New ICT-Based Multisensor Blood Pressure Monitoring System for Use in Hemodynamic Biomarker-Initiated Anticipation Medicine for Cardiovascular Disease: The National IMPACT Program Project.

    PubMed

    Kario, Kazuomi; Tomitani, Naoko; Kanegae, Hiroshi; Yasui, Nobuhiko; Nishizawa, Masafumi; Fujiwara, Takeshi; Shigezumi, Takeya; Nagai, Ryozo; Harada, Hiroshi

    We have developed a multisensor home and ambulatory blood pressure (BP) monitoring system for monitoring 24-h central and brachial BP variability concurrent with physical activity (PA), temperature, and atmospheric pressure. The new BP monitoring system utilizes our recently developed biological and environmental signal monitoring Information Communication Technology/Internet of Things system, which can simultaneously monitor the environment (temperature, illumination, etc.) of different rooms in a house (entryway, bedroom, living room, bathing room, and toilet), and a wrist-type high-sensitivity actigraph for identifying the location of patients. By collecting both data on BP and environmental parameters, the system can assess the brachial and central hemodynamic BP reactivity profiles of patients, such as actisensitivity (BP change with PA), thermosensitivity (with temperature), and atmospheric sensitivity (with atmospheric pressure). We used this new system to monitor ambulatory BP variability in outpatients with one or more cardiovascular disease (CVD) risk factors both in summer and winter. Actisensitivity (the slope of the regression line of ambulatory BP against the log-physical activity) was higher in winter than summer. By multi-level analysis using the parameters monitored by this system, we estimated the ambulatory BPs under different conditions. The individual time-series big data collected by this system will contribute to anticipation medicine for CVD. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Simultaneous monitoring of humidity and chemical changes using quartz crystal microbalance sensors modified with nano-thin films.

    PubMed

    Selyanchyn, Roman; Korposh, Serhiy; Wakamatsu, Shunichi; Lee, Seung-Woo

    2011-01-01

    Quartz crystal microbalance (QCM) electrodes modified with nano-thin films were used to develop a system for measuring significant environment changes (smoke, humidity, hazardous material release). A layer-by-layer approach was used for the deposition of sensitive coatings with a nanometer thickness on the electrode surface. The QCM electrode was modified with self-assembled alternate layers of tetrakis-(4-sulfophenyl) porphine (TSPP) (or its manganese derivative, MnTSPP) and poly(diallyldimethylammonium chloride) (PDDA). The QCM sensors, which had been reported previously for humidity sensing purposes, revealing a high possibility to recognize significant environmental changes. Identifying of the origin of environmental change is possible via differential signal analysis of the obtained data. The sensors showed different responses to humidity changes, hazardous gas (ammonia) or cigarette smoke exposure. Even qualitative analysis is not yet available; it has been shown that ventilation triggers or alarms for monitoring smoke or hazardous material release can be built using the obtained result.

  10. Phage phenomics: Physiological approaches to characterize novel viral proteins

    ScienceCinema

    Sanchez, Savannah E. [San Diego State Univ., San Diego, CA (United States); Cuevas, Daniel A. [San Diego State Univ., San Diego, CA (United States); Rostron, Jason E. [San Diego State Univ., San Diego, CA (United States); Liang, Tiffany Y. [San Diego State Univ., San Diego, CA (United States); Pivaroff, Cullen G. [San Diego State Univ., San Diego, CA (United States); Haynes, Matthew R. [San Diego State Univ., San Diego, CA (United States); Nulton, Jim [San Diego State Univ., San Diego, CA (United States); Felts, Ben [San Diego State Univ., San Diego, CA (United States); Bailey, Barbara A. [San Diego State Univ., San Diego, CA (United States); Salamon, Peter [San Diego State Univ., San Diego, CA (United States); Edwards, Robert A. [San Diego State Univ., San Diego, CA (United States); Argonne National Lab. (ANL), Argonne, IL (United States); Burgin, Alex B. [Broad Institute, Cambridge, MA (United States); Segall, Anca M. [San Diego State Univ., San Diego, CA (United States); Rohwer, Forest [San Diego State Univ., San Diego, CA (United States)

    2018-06-21

    Current investigations into phage-host interactions are dependent on extrapolating knowledge from (meta)genomes. Interestingly, 60 - 95% of all phage sequences share no homology to current annotated proteins. As a result, a large proportion of phage genes are annotated as hypothetical. This reality heavily affects the annotation of both structural and auxiliary metabolic genes. Here we present phenomic methods designed to capture the physiological response(s) of a selected host during expression of one of these unknown phage genes. Multi-phenotype Assay Plates (MAPs) are used to monitor the diversity of host substrate utilization and subsequent biomass formation, while metabolomics provides bi-product analysis by monitoring metabolite abundance and diversity. Both tools are used simultaneously to provide a phenotypic profile associated with expression of a single putative phage open reading frame (ORF). Thus, representative results for both methods are compared, highlighting the phenotypic profile differences of a host carrying either putative structural or metabolic phage genes. In addition, the visualization techniques and high throughput computational pipelines that facilitated experimental analysis are presented.

  11. Setting the stage for equity-sensitive monitoring of the maternal and child health Millennium Development Goals.

    PubMed Central

    Wirth, Meg E.; Balk, Deborah; Delamonica, Enrique; Storeygard, Adam; Sacks, Emma; Minujin, Alberto

    2006-01-01

    OBJECTIVE: This analysis seeks to set the stage for equity-sensitive monitoring of the health-related Millennium Development Goals (MDGs). METHODS: We use data from international household-level surveys (Demographic and Health Surveys (DHS) and Multiple Indicator Cluster Surveys (MICS)) to demonstrate that establishing an equity baseline is necessary and feasible, even in low-income and data-poor countries. We assess data from six countries using 11 health indicators and six social stratifiers. Simple bivariate stratification is complemented by simultaneous stratification to expose the compound effect of multiple forms of vulnerability. FINDINGS: The data reveal that inequities are complex and interactive: inferences cannot be drawn about the nature or extent of inequities in health outcomes from a single stratifier or indicator. CONCLUSION: The MDGs and other development initiatives must become more comprehensive and explicit in their analysis and tracking of inequities. The design of policies to narrow health gaps must take into account country-specific inequities. PMID:16878225

  12. Spectral-decomposition techniques for the identification of radon anomalies temporally associated with earthquakes occurring in the UK in 2002 and 2008.

    NASA Astrophysics Data System (ADS)

    Crockett, R. G. M.; Gillmore, G. K.

    2009-04-01

    During the second half of 2002, the University of Northampton Radon Research Group operated two continuous hourly-sampling radon detectors 2.25 km apart in Northampton, in the (English) East Midlands. This period included the Dudley earthquake (22/09/2002) which was widely noticed by members of the public in the Northampton area. Also, at various periods during 2008 the Group has operated another pair of continuous hourly-sampling radon detectors similar distances apart in Northampton. One such period included the Market Rasen earthquake (27/02/2008) which was also widely noticed by members of the public in the Northampton area. During each period of monitoring, two time-series of radon readings were obtained, one from each detector. These have been analysed for evidence of simultaneous similar anomalies: the premise being that big disturbances occurring at big distances (in relation to the detector separation) should produce simultaneous similar anomalies but that simultaneous anomalies occurring by chance will be dissimilar. As previously reported, cross-correlating the two 2002 time-series over periods of 1-30 days duration, rolled forwards through the time-series at one-hour intervals produced two periods of significant correlation, i.e. two periods of simultaneous similar behaviour in the radon concentrations. One of these periods corresponded in time to the Dudley earthquake, the other corresponded in time to a smaller earthquake which occurred in the English Channel (26/08/2002). We here report subsequent investigation of the 2002 time-series and the 2008 time-series using spectral-decomposition techniques. These techniques have revealed additional simultaneous similar behaviour in the two radon concentrations, not revealed by the rolling correlation on the raw data. These correspond in time to the Manchester earthquake swarm of October 2002 and the Market Rasen earthquake of February 2008. The spectral-decomposition techniques effectively ‘de-noise' the data, and also remove lower-frequency variations (e.g. tidal variations), revealing the simultaneous similarities. Whilst this is very much work in progress, there is the potential that such techniques enhance the possibility that simultaneous real-time monitoring of radon levels - for short-term simultaneous anomalies - at several locations in earthquake areas might provide the core of an earthquake prediction method. Keywords: Radon; earthquakes; time series; cross-correlation; spectral-decomposition; real-time simultaneous monitoring.

  13. Analysis of volatile thiols in alcoholic beverages by simultaneous derivatization/extraction and liquid chromatography-high resolution mass spectrometry.

    PubMed

    Vichi, Stefania; Cortés-Francisco, Nuria; Caixach, Josep

    2015-05-15

    A simultaneous derivatization/extraction method followed by liquid chromatography-electrospray-high resolution mass spectrometry for the determination of volatile thiols in hydroalcoholic matrixes was optimized and used to identify and quantify volatile thiols in wine and beer samples. The method was evaluated in terms of sensitivity, precision, accuracy and selectivity. The experimental LOQs of eleven thiols tested ranged between 0.01 ng/L and 10 ng/L. Intra-day relative standard deviation (RSD) was in general lower than 10% and inter-day RSD ranged between 10% and 30%. Recovery in the model and real matrixes ranged from 45% to 129%. The method was then applied for the analysis of four white wines and six beers. Five out of the eleven reference thiols were identified and quantified in the samples analyzed. The non-target approach, carried out by monitoring the diagnostic ion at m/z 275.9922 [C13H10ONSe](+) in the fragmentation spectrum, allowed detecting, in the same samples, fourteen non-target thiols. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Paralinear Oxidation of CVD SiC in Water Vapor

    NASA Technical Reports Server (NTRS)

    Opila, Elizabeth J.; Hann, Raiford E., Jr.

    1997-01-01

    The oxidation kinetics of CVD SiC were monitored by thermogravimetric analysis (TGA) in a 50% H2O/50% O2 gas mixture flowing at 4.4 cm/s for temperatures between 1200 and 1400 C. Paralinear weight change kinetics were observed as the water vapor oxidized the SiC and simultaneously volatilized the silica scale. The long-term degradation rate of SiC is determined by the volatility of the silica scale. Rapid SiC surface recession rates were estimated from these data for actual aircraft engine combustor conditions.

  15. A rapid space-resolved solid-phase microextraction method as a powerful tool to determine contaminants in wine based on their volatility.

    PubMed

    Liu, Min; Peng, Qing-Qing; Chen, Yu-Feng; Tang, Qian; Feng, Qing

    2015-06-01

    A novel space-resolved solid phase microextraction (SR-SPME) technique was developed to facilitate simultaneously analyte monitoring within heterogeneous samples. Graphene (G) and graphene oxide (GO) were coated separately to the segmented fibers which were successfully used for the solid-phase microextraction of two contaminants with dramatically different volatility: 2,4,6-trichloroanisole (TCA) and dibutyl phthalate (DBP). The space-resolved fiber showed good precision (5.4%, 6.8%), low detection limits (0.3ng/L, 0.3ng/L), and wide linearity (1.0-250.0ng/L, 1.0-250.0ng/L) under the optimized conditions for TCA and DBP, respectively. The method was applied to simultaneous analysis of the two contaminates with satisfactory recoveries, which were 96.96% and 98.20% for wine samples. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. STATS: a unique high speed, multiple channel, real-time data acquisition system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ross, F.A.; O'Connell, L.; Trellue, R.

    1980-01-01

    A Stand Alone Test System, called STATS, was developd to acquire and analyze data from as many as 120 analog channels. STATS is used in testing weapon systems under simulated environments at a laboratory in Texas. Some analog channels are sampled every 10 microseconds, but most are digitized every 100 microseconds. STATS features hardware data compression and a first-in-first-out buffer for each channel. It has also provided a way for the test configuration to be controlled by the diskette files that contain the test specifications. The analysis specifications are also predefined in diskette files keyed to the particular test type.more » The techniques used are applicable when many channels must be monitored simultaneously, channel activity comes in spurts separated by long quiet periods, and more than a few channels experience nearly simultaneous bursts of activity.« less

  17. Simultaneous Detection of Metalloprotease Activities in Complex Biological Samples Using the PrAMA (Proteolytic Activity Matrix Assay) Method.

    PubMed

    Conrad, Catharina; Miller, Miles A; Bartsch, Jörg W; Schlomann, Uwe; Lauffenburger, Douglas A

    2017-01-01

    Proteolytic Activity Matrix Analysis (PrAMA) is a method for simultaneously determining the activities of specific Matrix Metalloproteinases (MMPs) and A Disintegrin and Metalloproteinases (ADAMs) in complex biological samples. In mixtures of unknown proteases, PrAMA infers selective metalloproteinase activities by using a panel of moderately specific FRET-based polypeptide protease substrates in parallel, typically monitored by a plate-reader in a 96-well format. Fluorescence measurements are then quantitatively compared to a standard table of catalytic efficiencies measured from purified mixtures of individual metalloproteinases and FRET substrates. Computational inference of specific activities is performed with an easily used Matlab program, which is provided herein. Thus, we describe PrAMA as a combined experimental and mathematical approach to determine real-time metalloproteinase activities, which has previously been applied to live-cell cultures, cellular lysates, cell culture supernatants, and body fluids from patients.

  18. Use of a pressure sensing sheath: comparison with standard means of blood pressure monitoring in catheterization procedures

    PubMed Central

    Purdy, Phillip D; South, Charles; Klucznik, Richard P; Liu, Kenneth C; Novakovic, Robin L; Puri, Ajit S; Pride, G Lee; Aagaard-Kienitz, Beverly; Ray, Abishek; Elliott, Alan C

    2017-01-01

    Purpose Monitoring of blood pressure (BP) during procedures is variable, depending on multiple factors. Common methods include sphygmomanometer (BP cuff), separate radial artery catheterization, and side port monitoring of an indwelling sheath. Each means of monitoring has disadvantages, including time consumption, added risk, and signal dampening due to multiple factors. We sought an alternative approach to monitoring during procedures in the catheterization laboratory. Methods A new technology involving a 330 µm fiberoptic sensor embedded in the wall of a sheath structure was tested against both radial artery catheter and sphygmomanometer readings obtained simultaneous with readings recorded from the pressure sensing system (PSS). Correlations and Bland–Altman analysis were used to determine whether use of the PSS could substitute for these standard techniques. Results The results indicated highly significant correlations in systolic, diastolic, and mean arterial pressures (MAP) when compared against radial artery catheterization (p<0.0001), and MAP means differed by <4%. Bland–Altman analysis of the data suggested that the sheath measurements can replace a separate radial artery catheter. While less striking, significant correlations were seen when PSS readings were compared against BP cuff readings. Conclusions The PSS has competitive functionality to that seen with a dedicated radial artery catheter for BP monitoring and is available immediately on sheath insertion without the added risk of radial catheterization. The sensor is structurally separated from the primary sheath lumen and readings are unaffected by device introduction through the primary lumen. Time delays and potential complications from radial artery catheterization are avoided. PMID:27422970

  19. SimExTargId: A comprehensive package for real-time LC-MS data acquisition and analysis.

    PubMed

    Edmands, William M B; Hayes, Josie; Rappaport, Stephen M

    2018-05-22

    Liquid chromatography mass spectrometry (LC-MS) is the favored method for untargeted metabolomic analysis of small molecules in biofluids. Here we present SimExTargId, an open-source R package for autonomous analysis of metabolomic data and real-time observation of experimental runs. This simultaneous, fully automated and multi-threaded (optional) package is a wrapper for vendor-independent format conversion (ProteoWizard), xcms- and CAMERA- based peak-picking, MetMSLine-based pre-processing and covariate-based statistical analysis. Users are notified of detrimental instrument drift or errors by email. Also included are two shiny applications, targetId for real-time MS2 target identification, and peakMonitor to monitor targeted metabolites. SimExTargId is publicly available under GNU LGPL v3.0 license at https://github.com/JosieLHayes/simExTargId, which includes a vignette with example data. SimExTargId should be installed on a dedicated data-processing workstation or server that is networked to the LC-MS platform to facilitate MS1 profiling of metabolomic data. josie.hayes@berkeley.edu. Supplementary data are available at Bioinformatics online.

  20. Hyphenation of Raman spectroscopy with gravimetric analysis to interrogate water-solid interactions in pharmaceutical systems.

    PubMed

    Gift, Alan D; Taylor, Lynne S

    2007-01-04

    A moisture sorption gravimetric analyzer has been combined with a Raman spectrometer to better understand the various modes of water-solid interactions relevant to pharmaceutical systems. A commercial automated moisture sorption balance was modified to allow non-contact monitoring of the sample properties by interfacing a Raman probe with the sample holder. This hybrid instrument allows for gravimetric and spectroscopic changes to be monitored simultaneously. The utility of this instrument was demonstrated by investigating different types of water-solid interactions including stoichiometric and non-stoichiometric hydrate formation, deliquescence, amorphous-crystalline transformation, and capillary condensation. In each of the model systems, sulfaguanidine, cromolyn sodium, ranitidine HCl, amorphous sucrose and silica gel, spectroscopic changes were observed during the time course of the moisture sorption profile. Analysis of spectroscopic data provided information about the origin of the observed changes in moisture content as a function of relative humidity. Furthermore, multivariate data analysis techniques were employed as a means of processing the spectroscopic data. Principle components analysis was found to be useful to aid in data processing, handling and interpretation of the spectral changes that occurred during the time course of the moisture sorption profile.

  1. Understanding of safety monitoring in clinical trials by individuals with CF or their parents: A qualitative analysis.

    PubMed

    Kern-Goldberger, Andrew S; Hessels, Amanda J; Saiman, Lisa; Quittell, Lynne M

    2018-03-14

    Recruiting both pediatric and adult participants for clinical trials in CF is currently of paramount importance as numerous new therapies are being developed. However, recruitment is challenging as parents of children with CF and adults with CF cite safety concerns as a principal barrier to enrollment. In conjunction with the CF Foundation (CFF) Data Safety Monitoring Board (DSMB), a pilot brochure was developed to inform patients and parents of the multiple levels of safety monitoring; the CFF simultaneously created an infographic representing the safety monitoring process. This study explores the attitudes and beliefs of CF patients and families regarding safety monitoring and clinical trial participation, and elicits feedback regarding the educational materials. Semi-structured interviews were conducted using a pre-tested interview guide and audio-recorded during routine CF clinic visits. Participants included 5 parents of children with CF <16years old; 5 adolescents and young adults with CF 16-21years old; and 5 adults with CF ≥22years old from pediatric and adult CF centers. The study team performed systematic text condensation analysis of the recorded interviews using an iterative process. Four major thematic categories with subthemes emerged as supported by exemplar quotations: attitudes toward clinical trials, safety values, conceptualizing the safety monitoring process, and priorities for delivery of patient education. Participant feedback was used to revise the pilot brochure; text was shortened, unfamiliar words clarified (e.g., "pipeline"), abbreviations eliminated, and redundancy avoided. Qualitative analysis of CF patient and family interviews provided insights into barriers to participation in clinical trials, safety concerns, perspectives on safety monitoring and educational priorities. We plan a multicenter study to determine if the revised brochure reduces knowledge, attitude and practice barriers regarding participation in CF clinical trials. Copyright © 2018 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  2. On the Design of an Efficient Cardiac Health Monitoring System Through Combined Analysis of ECG and SCG Signals.

    PubMed

    Sahoo, Prasan Kumar; Thakkar, Hiren Kumar; Lin, Wen-Yen; Chang, Po-Cheng; Lee, Ming-Yih

    2018-01-28

    Cardiovascular disease (CVD) is a major public concern and socioeconomic problem across the globe. The popular high-end cardiac health monitoring systems such as magnetic resonance imaging (MRI), computerized tomography scan (CT scan), and echocardiography (Echo) are highly expensive and do not support long-term continuous monitoring of patients without disrupting their activities of daily living (ADL). In this paper, the continuous and non-invasive cardiac health monitoring using unobtrusive sensors is explored aiming to provide a feasible and low-cost alternative to foresee possible cardiac anomalies in an early stage. It is learned that cardiac health monitoring based on sole usage of electrocardiogram (ECG) signals may not provide powerful insights as ECG provides shallow information on various cardiac activities in the form of electrical impulses only. Hence, a novel low-cost, non-invasive seismocardiogram (SCG) signal along with ECG signals are jointly investigated for the robust cardiac health monitoring. For this purpose, the in-laboratory data collection model is designed for simultaneous acquisition of ECG and SCG signals followed by mechanisms for the automatic delineation of relevant feature points in acquired ECG and SCG signals. In addition, separate feature points based novel approach is adopted to distinguish between normal and abnormal morphology in each ECG and SCG cardiac cycle. Finally, a combined analysis of ECG and SCG is carried out by designing a Naïve Bayes conditional probability model. Experiments on Institutional Review Board (IRB) approved licensed ECG/SCG signals acquired from real subjects containing 12,000 cardiac cycles show that the proposed feature point delineation mechanisms and abnormal morphology detection methods consistently perform well and give promising results. In addition, experimental results show that the combined analysis of ECG and SCG signals provide more reliable cardiac health monitoring compared to the standalone use of ECG and SCG.

  3. On the Design of an Efficient Cardiac Health Monitoring System Through Combined Analysis of ECG and SCG Signals

    PubMed Central

    Lin, Wen-Yen; Chang, Po-Cheng

    2018-01-01

    Cardiovascular disease (CVD) is a major public concern and socioeconomic problem across the globe. The popular high-end cardiac health monitoring systems such as magnetic resonance imaging (MRI), computerized tomography scan (CT scan), and echocardiography (Echo) are highly expensive and do not support long-term continuous monitoring of patients without disrupting their activities of daily living (ADL). In this paper, the continuous and non-invasive cardiac health monitoring using unobtrusive sensors is explored aiming to provide a feasible and low-cost alternative to foresee possible cardiac anomalies in an early stage. It is learned that cardiac health monitoring based on sole usage of electrocardiogram (ECG) signals may not provide powerful insights as ECG provides shallow information on various cardiac activities in the form of electrical impulses only. Hence, a novel low-cost, non-invasive seismocardiogram (SCG) signal along with ECG signals are jointly investigated for the robust cardiac health monitoring. For this purpose, the in-laboratory data collection model is designed for simultaneous acquisition of ECG and SCG signals followed by mechanisms for the automatic delineation of relevant feature points in acquired ECG and SCG signals. In addition, separate feature points based novel approach is adopted to distinguish between normal and abnormal morphology in each ECG and SCG cardiac cycle. Finally, a combined analysis of ECG and SCG is carried out by designing a Naïve Bayes conditional probability model. Experiments on Institutional Review Board (IRB) approved licensed ECG/SCG signals acquired from real subjects containing 12,000 cardiac cycles show that the proposed feature point delineation mechanisms and abnormal morphology detection methods consistently perform well and give promising results. In addition, experimental results show that the combined analysis of ECG and SCG signals provide more reliable cardiac health monitoring compared to the standalone use of ECG and SCG. PMID:29382098

  4. Combined sensing platform for advanced diagnostics in exhaled mouse breath

    NASA Astrophysics Data System (ADS)

    Fortes, Paula R.; Wilk, Andreas; Seichter, Felicia; Cajlakovic, Merima; Koestler, Stefan; Ribitsch, Volker; Wachter, Ulrich; Vogt, Josef; Radermacher, Peter; Carter, Chance; Raimundo, Ivo M.; Mizaikoff, Boris

    2013-03-01

    Breath analysis is an attractive non-invasive strategy for early disease recognition or diagnosis, and for therapeutic progression monitoring, as quantitative compositional analysis of breath can be related to biomarker panels provided by a specific physiological condition invoked by e.g., pulmonary diseases, lung cancer, breast cancer, and others. As exhaled breath contains comprehensive information on e.g., the metabolic state, and since in particular volatile organic constituents (VOCs) in exhaled breath may be indicative of certain disease states, analytical techniques for advanced breath diagnostics should be capable of sufficient molecular discrimination and quantification of constituents at ppm-ppb - or even lower - concentration levels. While individual analytical techniques such as e.g., mid-infrared spectroscopy may provide access to a range of relevant molecules, some IR-inactive constituents require the combination of IR sensing schemes with orthogonal analytical tools for extended molecular coverage. Combining mid-infrared hollow waveguides (HWGs) with luminescence sensors (LS) appears particularly attractive, as these complementary analytical techniques allow to simultaneously analyze total CO2 (via luminescence), the 12CO2/13CO2 tracer-to-tracee (TTR) ratio (via IR), selected VOCs (via IR) and O2 (via luminescence) in exhaled breath, yet, establishing a single diagnostic platform as both sensors simultaneously interact with the same breath sample volume. In the present study, we take advantage of a particularly compact (shoebox-size) FTIR spectrometer combined with novel substrate-integrated hollow waveguide (iHWG) recently developed by our research team, and miniaturized fiberoptic luminescence sensors for establishing a multi-constituent breath analysis tool that is ideally compatible with mouse intensive care stations (MICU). Given the low tidal volume and flow of exhaled mouse breath, the TTR is usually determined after sample collection via gas chromatography coupled to mass spectrometric detection. Here, we aim at potentially continuously analyzing the TTR via iHWGs and LS flow-through sensors requiring only minute (< 1 mL) sample volumes. Furthermore, this study explores non-linearities observed for the calibration functions of 12CO2 and 13CO2 potentially resulting from effects related to optical collision diameters e.g., in presence of molecular oxygen. It is anticipated that the simultaneous continuous analysis of oxygen via LS will facilitate the correction of these effects after inclusion within appropriate multivariate calibration models, thus providing more reliable and robust calibration schemes for continuously monitoring relevant breath constituents.

  5. Monitoring intracellular oxidative events using dynamic spectral unmixing microscopy

    EPA Science Inventory

    There is increasing interest in using live-cell imaging to monitor not just individual intracellular endpoints, but to investigate the interplay between multiple molecular events as they unfold in real time within the cell. A major impediment to simultaneous acquisition of multip...

  6. Low-cost mobile air pollution monitoring in urban environments: a pilot study in Lubbock, Texas.

    PubMed

    McKercher, Grant R; Vanos, Jennifer K

    2018-06-01

    The complex nature of air pollution in urban areas prevents traditional monitoring techniques from obtaining measurements representative of true human exposure. The current study assessed the capability of low-cost mobile monitors to acquire useful data in a city without a monitoring network in place (Lubbock, Texas) using a bicycle platform. The monitoring campaign resulted in 30 days of data along a 13.4 km fixed concentric route. Due to high sensitivities to airflow, the apparent wind velocity was accounted for throughout the route. The data were also normalized into percentiles in order to visualize spatial patterns. The highest estimated pollution levels were located near frequently busy intersections and roads; however, sensor issues resulted in lower confidence. Additional research is needed concerning the appropriate use of low-cost metal oxide sensors for citizen science applications, as measurements can be misleading if the user is unaware of sensors specifications. The simultaneous use of several low-cost mobile platforms, rather than a single platform, as well as the use of high-end cases, are recommended to create a more robust spatial analysis. The issues addressed from this research are important to understand for accurate and beneficial application of low-cost gaseous monitors for citizen science.

  7. A Ringdown Breath Analyzer for Diabetes Monitoring: Breath Acetone in Diabetic Patients.

    NASA Astrophysics Data System (ADS)

    Wang, Chuji; Mbi, Armstrong; Shepherd, Mark

    2008-03-01

    It is highly desirable for millions of diabetic patients to have a non-blood, non-invasive, point-of-care device for monitoring daily blood glucose (BG) levels and the adequacy of diabetic treatment and control. Cavity ringdown spectroscopy, due to its unique capability of high sensitivity, fast-response, and relatively low cost for instrumentation, has the potential for medical application through non-invasive analysis of breath biomarkers. We report the first ringdown acetone breath analyzer for clinic testing with diabetic outpatients. The instrument was set in a clinic center and 34 outpatients (24 T1D and 10 T2D) were tested during a four-day period. 10 T1D subjects and 15 nondiabetic persons were tested in our laboratory. Three juvenile-onset T1D subjects were selected for a 24-hr monitoring on the variations of breath acetone and simultaneous BG level. In this talk, we present our research findings including the correlations of breath acetone with BG level and A1C.

  8. Reflectance-mode interferometric near-infrared spectroscopy quantifies brain absorption, scattering, and blood flow index in vivo

    PubMed Central

    Borycki, Dawid; Kholiqov, Oybek; Srinivasan, Vivek J.

    2017-01-01

    Interferometric near-infrared spectroscopy (iNIRS) is a new technique that measures time-of-flight- (TOF-) resolved autocorrelations in turbid media, enabling simultaneous estimation of optical and dynamical properties. Here, we demonstrate reflectance-mode iNIRS for noninvasive monitoring of a mouse brain in vivo. A method for more precise quantification with less static interference from superficial layers, based on separating static and dynamic components of the optical field autocorrelation, is presented. Absolute values of absorption, reduced scattering, and blood flow index (BFI) are measured, and changes in BFI and absorption are monitored during a hypercapnic challenge. Absorption changes from TOF-resolved iNIRS agree with absorption changes from continuous wave NIRS analysis, based on TOF-integrated light intensity changes, an effective path length, and the modified Beer–Lambert Law. Thus, iNIRS is a promising approach for quantitative and non-invasive monitoring of perfusion and optical properties in vivo. PMID:28146535

  9. Predicting US Drought Monitor (USDM) states using precipitation, soil moisture, and evapotranspiration anomalies, Part I: Development of a non-discrete USDM index

    USDA-ARS?s Scientific Manuscript database

    The U.S. Drought Monitor (USDM) classifies drought into five discrete dryness/drought categories based on expert synthesis of numerous data sources. In this study, an empirical methodology is presented for creating a non-discrete U.S. Drought Monitor (USDM) index that simultaneously 1) represents th...

  10. Layered acoustofluidic resonators for the simultaneous optical and acoustic characterisation of cavitation dynamics, microstreaming, and biological effects.

    PubMed

    Pereno, V; Aron, M; Vince, O; Mannaris, C; Seth, A; de Saint Victor, M; Lajoinie, G; Versluis, M; Coussios, C; Carugo, D; Stride, E

    2018-05-01

    The study of the effects of ultrasound-induced acoustic cavitation on biological structures is an active field in biomedical research. Of particular interest for therapeutic applications is the ability of oscillating microbubbles to promote both cellular and tissue membrane permeabilisation and to improve the distribution of therapeutic agents in tissue through extravasation and convective transport. The mechanisms that underpin the interaction between cavitating agents and tissues are, however, still poorly understood. One challenge is the practical difficulty involved in performing optical microscopy and acoustic emissions monitoring simultaneously in a biologically compatible environment. Here we present and characterise a microfluidic layered acoustic resonator ( μ LAR) developed for simultaneous ultrasound exposure, acoustic emissions monitoring, and microscopy of biological samples. The μ LAR facilitates in vitro ultrasound experiments in which measurements of microbubble dynamics, microstreaming velocity fields, acoustic emissions, and cell-microbubble interactions can be performed simultaneously. The device and analyses presented provide a means of performing mechanistic in vitro studies that may benefit the design of predictable and effective cavitation-based ultrasound treatments.

  11. Simultaneous radiofrequency (RF) heating and magnetic resonance (MR) thermal mapping using an intravascular MR imaging/RF heating system.

    PubMed

    Qiu, Bensheng; El-Sharkawy, Abdel-Monem; Paliwal, Vaishali; Karmarkar, Parag; Gao, Fabao; Atalar, Ergin; Yang, Xiaoming

    2005-07-01

    Previous studies have confirmed the possibility of using an intravascular MR imaging guidewire (MRIG) as a heating source to enhance vascular gene transfection/expression. This motivated us to develop a new intravascular system that can perform MR imaging, radiofrequncy (RF) heating, and MR temperature monitoring simultaneously in an MR scanner. To validate this concept, a series of mathematical simulations of RF power loss along a 0.032-inch MRIG and RF energy spatial distribution were performed to determine the optimum RF heating frequency. Then, an RF generator/amplifier and a filter box were built. The possibility for simultaneous RF heating and MR thermal mapping of the system was confirmed in vitro using a phantom, and the obtained thermal mapping profile was compared with the simulated RF power distribution. Subsequently, the feasibility of simultaneous RF heating and temperature monitoring was successfully validated in vivo in the aorta of living rabbits. This MR imaging/RF heating system offers a potential tool for intravascular MR-mediated, RF-enhanced vascular gene therapy.

  12. Process monitored spectrophotometric titration coupled with chemometrics for simultaneous determination of mixtures of weak acids.

    PubMed

    Liao, Lifu; Yang, Jing; Yuan, Jintao

    2007-05-15

    A new spectrophotometric titration method coupled with chemometrics for the simultaneous determination of mixtures of weak acids has been developed. In this method, the titrant is a mixture of sodium hydroxide and an acid-base indicator, and the indicator is used to monitor the titration process. In a process of titration, both the added volume of titrant and the solution acidity at each titration point can be obtained simultaneously from an absorption spectrum by least square algorithm, and then the concentration of each component in the mixture can be obtained from the titration curves by principal component regression. The method only needs the information of absorbance spectra to obtain the analytical results, and is free of volumetric measurements. The analyses are independent of titration end point and do not need the accurate values of dissociation constants of the indicator and the acids. The method has been applied to the simultaneous determination of the mixtures of benzoic acid and salicylic acid, and the mixtures of phenol, o-chlorophenol and p-chlorophenol with satisfactory results.

  13. Rapid Method for the Radioisotopic Analysis of Gaseous End Products of Anaerobic Metabolism

    PubMed Central

    Nelson, David R.; Zeikus, J. G.

    1974-01-01

    A gas chromatographic procedure for the simultaneous analysis of 14C-labeled and unlabeled metabolic gases from microbial methanogenic systems is described. H2, CH4, and CO2 were separated within 2.5 min on a Carbosieve B column and were detected by thermal conductivity. Detector effluents were channeled into a gas proportional counter for measurement of radioactivity. This method was more rapid, sensitive, and convenient than gas chromatography-liquid scintillation techniques. The gas chromatography-gas proportional counting procedure was used to characterize the microbial decomposition of organic matter in anaerobic lake sediments and to monitor 14CH4 formation from H2 and 14CO2 by Methanosarcina barkeri. PMID:4854029

  14. Development of an alpha/beta/gamma detector for radiation monitoring

    NASA Astrophysics Data System (ADS)

    Yamamoto, Seiichi; Hatazawa, Jun

    2011-11-01

    For radiation monitoring at the site of nuclear power plant accidents such as Fukushima Daiichi, radiation detectors not only for gamma photons but also for alpha and beta particles are needed because some nuclear fission products emit beta particles and gamma photons and some nuclear fuels contain plutonium that emits alpha particles. We developed a radiation detector that can simultaneously monitor alpha and beta particles and gamma photons for radiation monitoring. The detector consists of three-layered scintillators optically coupled to each other and coupled to a photomultiplier tube. The first layer, which is made of a thin plastic scintillator (decay time: 2.4 ns), detects alpha particles. The second layer, which is made of a thin Gd2SiO5 (GSO) scintillator with 1.5 mol.% Ce (decay time: 35 ns), detects beta particles. The third layer made of a thin GSO scintillator with 0.4 mol.% Ce (decay time: 70 ns) detects gamma photons. By using pulse shape discrimination, the count rates of these layers can be separated. With individual irradiation of alpha and beta particles and gamma photons, the count rate of the first layer represented the alpha particles, the second layer represented the beta particles, and the third layer represented the gamma photons. Even with simultaneous irradiation of the alpha and beta particles and the gamma photons, these three types of radiation can be individually monitored using correction for the gamma detection efficiency of the second and third layers. Our developed alpha, beta, and gamma detector is simple and will be useful for radiation monitoring, especially at nuclear power plant accident sites or other applications where the simultaneous measurements of alpha and beta particles and gamma photons are required.

  15. Development of an alpha/beta/gamma detector for radiation monitoring.

    PubMed

    Yamamoto, Seiichi; Hatazawa, Jun

    2011-11-01

    For radiation monitoring at the site of nuclear power plant accidents such as Fukushima Daiichi, radiation detectors not only for gamma photons but also for alpha and beta particles are needed because some nuclear fission products emit beta particles and gamma photons and some nuclear fuels contain plutonium that emits alpha particles. We developed a radiation detector that can simultaneously monitor alpha and beta particles and gamma photons for radiation monitoring. The detector consists of three-layered scintillators optically coupled to each other and coupled to a photomultiplier tube. The first layer, which is made of a thin plastic scintillator (decay time: 2.4 ns), detects alpha particles. The second layer, which is made of a thin Gd(2)SiO(5) (GSO) scintillator with 1.5 mol.% Ce (decay time: 35 ns), detects beta particles. The third layer made of a thin GSO scintillator with 0.4 mol.% Ce (decay time: 70 ns) detects gamma photons. By using pulse shape discrimination, the count rates of these layers can be separated. With individual irradiation of alpha and beta particles and gamma photons, the count rate of the first layer represented the alpha particles, the second layer represented the beta particles, and the third layer represented the gamma photons. Even with simultaneous irradiation of the alpha and beta particles and the gamma photons, these three types of radiation can be individually monitored using correction for the gamma detection efficiency of the second and third layers. Our developed alpha, beta, and gamma detector is simple and will be useful for radiation monitoring, especially at nuclear power plant accident sites or other applications where the simultaneous measurements of alpha and beta particles and gamma photons are required. © 2011 American Institute of Physics

  16. Optical quasi-distributed simultaneous vibration and temperature sensing in stator bars of a 370-MVA electric generator

    NASA Astrophysics Data System (ADS)

    Dreyer, Uilian José; Vagner da Silva, Erlon; Martelli, Cicero; Cardozo da Silva, Jean Carlos

    2017-08-01

    In this paper, we propose a new multiparametric optical fiber transducer applied to an electric generator of 370 MVA. The optical transducer has three multiplexed FBGs in the same optical fiber as the sensing element. The FBG sensors can simultaneously measure both the temperature and vibration independently of the other multiplexed FBGs. The installation in the power plant was performed using six transducers and it was obtained 23 hours of simultaneous vibration and temperature measurement. All the FBGs used to monitor generator vibration were able to monitor the frequency of mechanical and electromagnetic vibrations, which were measured at 2 Hz and 120 Hz, respectively. During the measurement, the machine was turned off due to a failure and all the FBGs sensed temperature changes, as well as frequency vibration changes. The largest temperature difference measured between the FBGs during the test is approximately 2°C.

  17. Automated plasma control with optical emission spectroscopy

    NASA Astrophysics Data System (ADS)

    Ward, P. P.

    Plasma etching and desmear processes for printed wiring board (PWB) manufacture are difficult to predict and control. Non-uniformity of most plasma processes and sensitivity to environmental changes make it difficult to maintain process stability from day to day. To assure plasma process performance, weight loss coupons or post-plasma destructive testing must be used. These techniques are not real-time methods however, and do not allow for immediate diagnosis and process correction. These tests often require scrapping some fraction of a batch to insure the integrity of the rest. Since these tests verify a successful cycle with post-plasma diagnostics, poor test results often determine that a batch is substandard and the resulting parts unusable. These tests are a costly part of the overall fabrication cost. A more efficient method of testing would allow for constant monitoring of plasma conditions and process control. Process anomalies should be detected and corrected before the parts being treated are damaged. Real time monitoring would allow for instantaneous corrections. Multiple site monitoring would allow for process mapping within one system or simultaneous monitoring of multiple systems. Optical emission spectroscopy conducted external to the plasma apparatus would allow for this sort of multifunctional analysis without perturbing the glow discharge. In this paper, optical emission spectroscopy for non-intrusive, in situ process control will be explored along with applications of this technique to for process control, failure analysis and endpoint determination in PWB manufacture.

  18. A clinical evaluation of a remote mobility monitoring system based on SMS messaging.

    PubMed

    Dalton, Anthony F; Ní Scanaill, Cliodhna; Carew, Sheila; Lyons, Declan; OLaighin, Gearóid

    2007-01-01

    The objective of this work was to evaluate the accuracy and viability of a mobility telemonitoring system, based on the short message service (SMS), to monitor the functional mobility of elderly subjects in an unsupervised environment. A clinical trial was conducted consisting of 6 elderly subjects; 3 male, 3 female (mean: 81.7, SD: 5.09). Mobility was monitored using an accelerometer based portable unit worn by each monitored subject for eleven hours. Every 15 minutes the mobility of the subject was summarized and transmitted as an SMS message from the portable unit to a remote server for long term analysis. The activPAL Trio Professional physical activity logger was simultaneously used for comparison with the portable unit. On conclusion of the trial each subject completed a questionnaire detailing their satisfaction with the portable unit and any recommendations for improvements. Overall a percentage difference of 2.31% was found between the activPAL Trio and the portable unit for the detection of sitting. For the combined postures of standing and walking the percentage difference was calculated as 2.9%. A bivariate correlation and regression analysis was performed on the entire data set of one subject. Strong positive correlation's were found for the detection of sitting (r = 0.996) and for the combined postures of standing and walking (r = 0.994). Subjects suggested that a lighter, smaller and wireless unit would be more effective.

  19. Estimation of Circadian Body Temperature Rhythm Based on Heart Rate in Healthy, Ambulatory Subjects.

    PubMed

    Sim, Soo Young; Joo, Kwang Min; Kim, Han Byul; Jang, Seungjin; Kim, Beomoh; Hong, Seungbum; Kim, Sungwan; Park, Kwang Suk

    2017-03-01

    Core body temperature is a reliable marker for circadian rhythm. As characteristics of the circadian body temperature rhythm change during diverse health problems, such as sleep disorder and depression, body temperature monitoring is often used in clinical diagnosis and treatment. However, the use of current thermometers in circadian rhythm monitoring is impractical in daily life. As heart rate is a physiological signal relevant to thermoregulation, we investigated the feasibility of heart rate monitoring in estimating circadian body temperature rhythm. Various heart rate parameters and core body temperature were simultaneously acquired in 21 healthy, ambulatory subjects during their routine life. The performance of regression analysis and the extended Kalman filter on daily body temperature and circadian indicator (mesor, amplitude, and acrophase) estimation were evaluated. For daily body temperature estimation, mean R-R interval (RRI), mean heart rate (MHR), or normalized MHR provided a mean root mean square error of approximately 0.40 °C in both techniques. The mesor estimation regression analysis showed better performance than the extended Kalman filter. However, the extended Kalman filter, combined with RRI or MHR, provided better accuracy in terms of amplitude and acrophase estimation. We suggest that this noninvasive and convenient method for estimating the circadian body temperature rhythm could reduce discomfort during body temperature monitoring in daily life. This, in turn, could facilitate more clinical studies based on circadian body temperature rhythm.

  20. New developments in automated biosensing from remote water quality stations and satellite data retrieval for resources management

    NASA Astrophysics Data System (ADS)

    Morgan, E. L.; Eagleson, K. W.; Hermann, R.; McCollough, N. D.

    1981-05-01

    Maintaining adequate water quality in a multipurpose drainage system becomes increasingly important as demands on resources become greater. Real-time water quality monitoring plays a crucial role in meeting this objective. In addition to remote automated physical monitoring, developments at the end of the 1970's allow simultaneous real-time measurements of fish breathing response to water quality changes. These advantages complement complex in-stream surveys typically carried out to evaluate the environmental quality of a system. Automated biosensing units having remote capabilities are designed to aid in the evaluation of subtle water quality changes contributing to undesirable conditions in a drainage basin. Using microprocessor-based monitors to measure fish breathing rates, the biosensing units are interfaced to a U.S. National Aeronautics and Space Administration (N.A.S.A.) remote data collection platform for National Oceanic and Atmospheric Administration (N.O.A.A.) GOES satellite retrieval and transmission of data. Simultaneously, multiparameter physical information is collected from site-specific locations and recovered in a similar manner. Real-time biological and physical data received at a data processing center are readily available for interpretation by resource managers. Management schemes incorporating real-time monitoring networks into on-going programs to simultaneously retrieve biological and physical data by satellite, radio and telephone cable give added advantages in maintaining water quality for multipurpose needs.

  1. Bird biodiversity assessments in temperate forest: the value of point count versus acoustic monitoring protocols.

    PubMed

    Klingbeil, Brian T; Willig, Michael R

    2015-01-01

    Effective monitoring programs for biodiversity are needed to assess trends in biodiversity and evaluate the consequences of management. This is particularly true for birds and faunas that occupy interior forest and other areas of low human population density, as these are frequently under-sampled compared to other habitats. For birds, Autonomous Recording Units (ARUs) have been proposed as a supplement or alternative to point counts made by human observers to enhance monitoring efforts. We employed two strategies (i.e., simultaneous-collection and same-season) to compare point count and ARU methods for quantifying species richness and composition of birds in temperate interior forests. The simultaneous-collection strategy compares surveys by ARUs and point counts, with methods matched in time, location, and survey duration such that the person and machine simultaneously collect data. The same-season strategy compares surveys from ARUs and point counts conducted at the same locations throughout the breeding season, but methods differ in the number, duration, and frequency of surveys. This second strategy more closely follows the ways in which monitoring programs are likely to be implemented. Site-specific estimates of richness (but not species composition) differed between methods; however, the nature of the relationship was dependent on the assessment strategy. Estimates of richness from point counts were greater than estimates from ARUs in the simultaneous-collection strategy. Woodpeckers in particular, were less frequently identified from ARUs than point counts with this strategy. Conversely, estimates of richness were lower from point counts than ARUs in the same-season strategy. Moreover, in the same-season strategy, ARUs detected the occurrence of passerines at a higher frequency than did point counts. Differences between ARU and point count methods were only detected in site-level comparisons. Importantly, both methods provide similar estimates of species richness and composition for the region. Consequently, if single visits to sites or short-term monitoring are the goal, point counts will likely perform better than ARUs, especially if species are rare or vocalize infrequently. However, if seasonal or annual monitoring of sites is the goal, ARUs offer a viable alternative to standard point-count methods, especially in the context of large-scale or long-term monitoring of temperate forest birds.

  2. Personal carbon monoxide exposures of preschool children in Helsinki, Finland—comparison to ambient air concentrations

    NASA Astrophysics Data System (ADS)

    Alm, S.; Mukala, K.; Tiittanen, P.; Jantunen, M. J.

    The associations of personal carbon monoxide (CO) exposures with ambient air CO concentrations measured at fixed monitoring sites, were studied among 194 children aged 3-6 yr in four downtown and four suburban day-care centers in Helsinki, Finland. Each child carried a personal CO exposure monitor between 1 and 4 times for a time period of between 20 and 24 h. CO concentrations at two fixed monitoring sites were measured simultaneously. The CO concentrations measured at the fixed monitoring sites were usually lower (mean maximum 8-h concentration: 0.9 and 2.6 mg m -3) than the personal CO exposure concentrations (mean maximum 8-h concentration: 3.3 mg m -3). The fixed site CO concentrations were poor predictors of the personal CO exposure concentrations. However, the correlations between the personal CO exposure and the fixed monitoring site CO concentrations increased (-0.03--0.12 to 0.13-0.16) with increasing averaging times from 1 to 8 h. Also, the fixed monitoring site CO concentrations explained the mean daily or weekly personal CO exposures of a group of simultaneously measured children better than individual exposure CO concentrations. This study suggests that the short-term CO personal exposure of children cannot be meaningfully assessed using fixed monitoring sites.

  3. US EPA Base Study Standard Operating Procedure for Continuous Monitoring of Outdoor Air

    EPA Pesticide Factsheets

    The procedure described is intended for monitoring continuously and simultaneously outdoor air quality parameters that are most commonly associated with indoor air quality: the concentrations of carbon dioxide (CO2) and carbon monoxide (CO), temperature, nd relative humidity (RH).

  4. Development of a brain monitoring system for multimodality investigation in awake rats.

    PubMed

    Limnuson, Kanokwan; Narayan, Raj K; Chiluwal, Amrit; Bouton, Chad; Ping Wang; Chunyan Li

    2016-08-01

    Multimodal brain monitoring is an important approach to gain insight into brain function, modulation, and pathology. We have developed a unique micromachined neural probe capable of real-time continuous monitoring of multiple physiological, biochemical and electrophysiological variables. However, to date, it has only been used in anesthetized animals due to a lack of an appropriate interface for awake animals. We have developed a versatile headstage for recording the small neural signal and bridging the sensors to the remote sensing units for multimodal brain monitoring in awake rats. The developed system has been successfully validated in awake rats by simultaneously measuring four cerebral variables: electrocorticography, oxygen tension, temperature and cerebral blood flow. Reliable signal recordings were obtained with minimal artifacts from movement and environmental noise. For the first time, multiple variables of cerebral function and metabolism were simultaneously recorded from awake rats using a single neural probe. The system is envisioned for studying the effects of pharmacologic treatments, mapping the development of central nervous system diseases, and better understanding normal cerebral physiology.

  5. Simultaneous dielectric monitoring of microfluidic channels at microwaves utilizing a metamaterial transmission line structure.

    PubMed

    Schüßler, M; Puentes, M; Dubuc, D; Grenier, K; Jakoby, R

    2012-01-01

    The paper presents a technique that allows the simultaneous monitoring of the dielectric properties of liquids in microfluidic channels at microwave frequencies. It is capable of being integrated within the lab-on-a-chip concept and uses a composite right/left-handed transmission line resonator which is detuned by the dielectric loading of the liquids in the channels. By monitoring the change in the resonance spectrum of the resonator the loading profile can be derived with the multi-resonant perturbation method. From the value of the dielectric constant inference on the substances like cells or chemicals in the channels can be drawn. The paper presents concept, design, fabrication and characterization of prototype sensors. The sensors have been designed to operate between 20 and 30 GHz and were tested with water and water ethanol mixtures.

  6. Rapid monitoring of intermediate states and mass balance of nitrogen during denitrification by means of cavity enhanced Raman multi-gas sensing.

    PubMed

    Keiner, Robert; Herrmann, Martina; Küsel, Kirsten; Popp, Jürgen; Frosch, Torsten

    2015-03-15

    The comprehensive investigation of changes in N cycling has been challenging so far due to difficulties with measuring gases such as N2 and N2O simultaneously. In this study we introduce cavity enhanced Raman gas spectroscopy as a new analytical methodology for tracing the stepwise reduction of (15)N-labelled nitrate by the denitrifying bacteria Pseudomonas stutzeri. The unique capabilities of Raman multi-gas analysis enabled real-time, continuous, and non-consumptive quantification of the relevant gases ((14)N2, (14)N2O, O2, and CO2) and to trace the fate of (15)N-labeled nitrate substrate ((15)N2, (15)N2O) added to a P. stutzeri culture with one single measurement. Using this new methodology, we could quantify the kinetics of the formation and degradation for all gaseous compounds (educts and products) and thus study the reaction orders. The gas quantification was complemented with the analysis of nitrate and nitrite concentrations for the online monitoring of the total nitrogen element budget. The simultaneous quantification of all gases also enabled the contactless and sterile online acquisition of the pH changes in the P. stutzeri culture by the stoichiometry of the redox reactions during denitrification and the CO2-bicarbonate equilibrium. Continuous pH monitoring - without the need to insert an electrode into solution - elucidated e.g. an increase in the slope of the pH value coinciding with an accumulation of nitrite, which in turn led to a temporary accumulation of N2O, due to an inhibition of nitrous oxide reductase. Cavity enhanced Raman gas spectroscopy has a high potential for the assessment of denitrification processes and can contribute substantially to our understanding of nitrogen cycling in both natural and agricultural systems. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Dynamic measurement of fluorescent proteins spectral distribution on virus infected cells

    NASA Astrophysics Data System (ADS)

    Lee, Ja-Yun; Wu, Ming-Xiu; Kao, Chia-Yun; Wu, Tzong-Yuan; Hsu, I.-Jen

    2006-09-01

    We constructed a dynamic spectroscopy system that can simultaneously measure the intensity and spectral distributions of samples with multi-fluorophores in a single scan. The system was used to monitor the fluorescence distribution of cells infected by the virus, which is constructed by a recombinant baculoviruses, vAcD-Rhir-E, containing the red and green fluorescent protein gene that can simultaneously produce dual fluorescence in recombinant virus-infected Spodoptera frugiperda 21 cells (Sf21) under the control of a polyhedrin promoter. The system was composed of an excitation light source, a scanning system and a spectrometer. We also developed an algorithm and fitting process to analyze the pattern of fluorescence distribution of the dual fluorescence produced in the recombinant virus-infected cells. All the algorithm and calculation are automatically processed in a visualized scanning program and can monitor the specific region of sample by calculating its intensity distribution. The spectral measurement of each pixel was performed at millisecond range and the two dimensional distribution of full spectrum was recorded within several seconds. We have constructed a dynamic spectroscopy system to monitor the process of virus-infection of cells. The distributions of the dual fluorescence were simultaneously measured at micrometer resolution.

  8. Simultaneous analysis of carbohydrates and organic acids by HPLC-DAD-RI for monitoring goat's milk yogurts fermentation.

    PubMed

    da Costa, Marion Pereira; Frasao, Beatriz da Silva; Lima, Bruno Reis Carneiro da Costa; Rodrigues, Bruna Leal; Conte Junior, Carlos Adam

    2016-05-15

    During yogurt manufacture, the lactose fermentation and organic acid production can be used to monitor the fermentation process by starter cultures and probiotic bacteria. In the present work, a simple, sensitive and reproducible high-performance liquid chromatography with dual detectors, diode array detector and refractive index was validated by simultaneous analysis of carbohydrates and organic acids in goat milk yogurts. In addition, pH and bacterial analysis were performed. Separation of all the compounds was performed on an Aminex HPX-87H column (300×7.8 mm, 9 µm) utilizing a 3 mmol L(-1) sulfuric acid aqueous mobile phase under isocratic conditions. Lactose, glucose, galactose, citric, lactic and formic acids were used to evaluate the following performance parameters: selectivity, linearity, precision, limit of detection (LOD), limit of quantification (LOQ), decision limits (CCα), detection capabilities (CCβ), recovery and robustness. For the method application a six goat milk yogurts were elaborated: natural, probiotic, prebiotic, symbiotic, cupuassu fruit pulp, and probiotic with cupuassu fruit pulp. The validated method presented an excellent selectivity with no significant matrix effect, and a broad linear study range with coefficients of determination higher than 0.995. The relative standard deviation was lower than 10% under repeatability and within-laboratory reproducibility conditions for the studied analytes. The LOD of the method was defined from 0.001 to 0.003 µg g(-1), and the LOQ from 0.003 to 0.013 µg g(-1). The CCα was ranged from 0.032 to 0.943 µg g(-1), and the CCβ from 0.053 to 1.604 µg g(-1). The obtained recovery values were from 78% to 119%. In addition, the method exhibited an appropriate robustness for all parameter evaluated. Base in our data, it was concluded that the performance parameters demonstrated total method adequacy for the detection and quantification of carbohydrates and organic acids in goat milk yogurts. The application of the method was successfully applied to monitoring different goat milk yogurts during fermentation. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Simultaneous multiplexed quantification of nicotine and its metabolites using surface enhanced Raman scattering.

    PubMed

    Alharbi, Omar; Xu, Yun; Goodacre, Royston

    2014-10-07

    The detection and quantification of xenobiotics and their metabolites in man is important for drug dosing, therapy and for substance abuse monitoring where longer-lived metabolic products from illicit materials can be assayed after the drug of abuse has been cleared from the system. Raman spectroscopy offers unique specificity for molecular characterization and this usually weak signal can be significantly enhanced using surface enhanced Raman scattering (SERS). We report here the novel development of SERS with chemometrics for the simultaneous analysis of the drug nicotine and its major xenometabolites cotinine and trans-3'-hydroxycotinine. Initial experiments optimized the SERS conditions and we found that when these three determinands were analysed individually that the maximum SERS signals were found at three different pH. These were pH 3 for nicotine and pH 10 and 11 for cotinine and trans-3'-hydroxycotinine, respectively. Tertiary mixtures containing nicotine, cotinine and trans-3'-hydroxycotinine were generated in the concentration range 10(-7)-10(-5) M and SERS spectra were collected at all three pH values. Chemometric analysis using kernel-partial least squares (K-PLS) and artificial neural networks (ANNs) were conducted and these models were validated using bootstrap resampling. All three analytes were accurately quantified with typical root mean squared error of prediction on the test set data being 5-9%; nicotine was most accurately predicted followed by cotinine and then trans-3'-hydroxycotinine. We believe that SERS is a powerful approach for the simultaneous analysis of multiple determinands without recourse to lengthy chromatography, as demonstrated here for the xenobiotic nicotine and its two major xenometabolites.

  10. Process monitoring and control with CHEMIN, a miniaturized CCD-based instrument for simultaneous XRD/XRF analysis

    NASA Astrophysics Data System (ADS)

    Vaniman, David T.; Bish, D.; Guthrie, G.; Chipera, S.; Blake, David E.; Collins, S. Andy; Elliott, S. T.; Sarrazin, P.

    1999-10-01

    There is a large variety of mining and manufacturing operations where process monitoring and control can benefit from on-site analysis of both chemical and mineralogic constituents. CHEMIN is a CCD-based instrument capable of both X-ray fluorescence (XRF; chemical) and X-ray diffraction (XRD; mineralogic) analysis. Monitoring and control with an instrument like CHEMIN can be applied to feedstocks, intermediate materials, and final products to optimize production. Examples include control of cement feedstock, of ore for smelting, and of minerals that pose inhalation hazards in the workplace. The combined XRD/XRF capability of CHEMIN can be used wherever a desired commodity is associated with unwanted constituents that may be similar in chemistry or structure but not both (e.g., Ca in both gypsum and feldspar, where only the gypsum is desired to make wallboard). In the mining industry, CHEMIN can determine mineral abundances on the spot and enable more economical mining by providing the means to assay when is being mined, quickly and frequently, at minimal cost. In manufacturing, CHEMIN could be used to spot-check the chemical composition and crystalline makeup of a product at any stage of production. Analysis by CHEMIN can be used as feedback in manufacturing processes where rates of heating, process temperature, mixture of feedstocks, and other variables must be adjusted in real time to correct structure and/or chemistry of the product (e.g., prevention of periclase and alkali sulfate coproduction in cement manufacture).

  11. Observations of transient events with Mini-MegaTORTORA wide-field monitoring system with sub-second temporal resolution

    NASA Astrophysics Data System (ADS)

    Karpov, S.; Beskin, G.; Biryukov, A.; Bondar, S.; Ivanov, E.; Katkova, E.; Orekhova, N.; Perkov, A.; Sasyuk, V.

    2017-07-01

    Here we present the summary of first years of operation and the first results of a novel 9-channel wide-field optical monitoring system with sub-second temporal resolution, Mini-MegaTORTORA (MMT-9), which is in operation now at Special Astrophysical Observatory on Russian Caucasus. The system is able to observe the sky simultaneously in either wide (900 square degrees) or narrow (100 square degrees) fields of view, either in clear light or with any combination of color (Johnson-Cousins B, V or R) and polarimetric filters installed, with exposure times ranging from 0.1 s to hundreds of seconds.The real-time system data analysis pipeline performs automatic detection of rapid transient events, both near-Earth and extragalactic. The objects routinely detected by MMT also include faint meteors and artificial satellites.

  12. Mini-MegaTORTORA Wide-Field Monitoring System with Subsecond Temporal Resolution: Observation of Transient Events

    NASA Astrophysics Data System (ADS)

    Karpov, S.; Beskin, G.; Biryukov, A.; Bondar, S.; Ivanov, E.; Katkova, E.; Orekhova, N.; Perkov, A.; Sasyuk, V.

    2017-06-01

    Here we present the summary of first years of operation and the first results of a novel 9-channel wide-field optical monitoring system with sub-second temporal resolution, Mini-MegaTORTORA (MMT-9), which is in operation now at Special Astrophysical Observatory on Russian Caucasus. The system is able to observe the sky simultaneously in either wide (˜900 square degrees) or narrow (˜100 square degrees) fields of view, either in clear light or with any combination of color (Johnson-Cousins B, V or R) and polarimetric filters installed, with exposure times ranging from 0.1 s to hundreds of seconds.The real-time system data analysis pipeline performs automatic detection of rapid transient events, both near-Earth and extragalactic. The objects routinely detected by MMT include faint meteors and artificial satellites.

  13. Monitoring muscle optical scattering properties during rigor mortis

    NASA Astrophysics Data System (ADS)

    Xia, J.; Ranasinghesagara, J.; Ku, C. W.; Yao, G.

    2007-09-01

    Sarcomere is the fundamental functional unit in skeletal muscle for force generation. In addition, sarcomere structure is also an important factor that affects the eating quality of muscle food, the meat. The sarcomere structure is altered significantly during rigor mortis, which is the critical stage involved in transforming muscle to meat. In this paper, we investigated optical scattering changes during the rigor process in Sternomandibularis muscles. The measured optical scattering parameters were analyzed along with the simultaneously measured passive tension, pH value, and histology analysis. We found that the temporal changes of optical scattering, passive tension, pH value and fiber microstructures were closely correlated during the rigor process. These results suggested that sarcomere structure changes during rigor mortis can be monitored and characterized by optical scattering, which may find practical applications in predicting meat quality.

  14. An automated environment for multiple spacecraft engineering subsystem mission operations

    NASA Technical Reports Server (NTRS)

    Bahrami, K. A.; Hioe, K.; Lai, J.; Imlay, E.; Schwuttke, U.; Hsu, E.; Mikes, S.

    1990-01-01

    Flight operations at the Jet Propulsion Laboratory (JPL) are now performed by teams of specialists, each team dedicated to a particular spacecraft. Certain members of each team are responsible for monitoring the performances of their respective spacecraft subsystems. Ground operations, which are very complex, are manual, labor-intensive, slow, and tedious, and therefore costly and inefficient. The challenge of the new decade is to operate a large number of spacecraft simultaneously while sharing limited human and computer resources, without compromising overall reliability. The Engineering Analysis Subsystem Environment (EASE) is an architecture that enables fewer controllers to monitor and control spacecraft engineering subsystems. A prototype of EASE has been installed in the JPL Space Flight Operations Facility for on-line testing. This article describes the underlying concept, development, testing, and benefits of the EASE prototype.

  15. Displacement-based back-analysis of the model parameters of the Nuozhadu high earth-rockfill dam.

    PubMed

    Wu, Yongkang; Yuan, Huina; Zhang, Bingyin; Zhang, Zongliang; Yu, Yuzhen

    2014-01-01

    The parameters of the constitutive model, the creep model, and the wetting model of materials of the Nuozhadu high earth-rockfill dam were back-analyzed together based on field monitoring displacement data by employing an intelligent back-analysis method. In this method, an artificial neural network is used as a substitute for time-consuming finite element analysis, and an evolutionary algorithm is applied for both network training and parameter optimization. To avoid simultaneous back-analysis of many parameters, the model parameters of the three main dam materials are decoupled and back-analyzed separately in a particular order. Displacement back-analyses were performed at different stages of the construction period, with and without considering the creep and wetting deformations. Good agreement between the numerical results and the monitoring data was obtained for most observation points, which implies that the back-analysis method and decoupling method are effective for solving complex problems with multiple models and parameters. The comparison of calculation results based on different sets of back-analyzed model parameters indicates the necessity of taking the effects of creep and wetting into consideration in the numerical analyses of high earth-rockfill dams. With the resulting model parameters, the stress and deformation distributions at completion are predicted and analyzed.

  16. A Sensitive Dilute-and-Shoot Approach for the Simultaneous Screening of 71 Stimulants and 7 Metabolites in Human Urine by LC-MS-MS with Dynamic MRM.

    PubMed

    Dong, Ying; Yan, Kuan; Ma, Yanhua; Wang, Shan; He, Genye; Deng, Jing; Yang, Zhiyong

    2015-10-01

    A novel, reliable and sensitive liquid chromatography-tandem mass spectrometry (LC-MS-MS) method was developed with dynamic multiple reaction monitoring (dMRM) mode for the simultaneous screening of 71 stimulants and 7 metabolites in human urine using unsophisticated MS instruments (Agilent triple-quadruple 6410 B mass spectrometer). With a known retention time of an analyte, dMRM algorithm monitors each MRM transition only around its expected retention time. Therefore, dMRM enables the maximization of dwell times and provides much higher sensitivity and reproducibility than the conventional multiple reaction monitoring mode (cMRM). After precipitation of protein, the urine sample was injected into LC-MS-MS system directly without sample pre-concentration. For comparison, cMRM and dMRM acquisitions were performed under the same chromatographic conditions. The result showed that the signal response and quality of the chromatograms for each stimulant improved significantly with dMRM over cMRM. The method has been fully validated giving limits of detection (0.1-25 ng/mL) satisfactory for its application to anti-doping analysis. The repeatability of the concentrations and the retention times are good both for intra- and for inter-day experiments (%CV of concentrations always <20 and %CV of retention times <0.5). The method also afforded satisfactory results in terms of accuracy, matrix effect and specificity. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Relative skills of soil moisture and vegetation optical depth retrievals for agricultural drought monitoring

    USDA-ARS?s Scientific Manuscript database

    Soil moisture condition is an important indicator for agricultural drought monitoring. Through the Land Parameter Retrieval Model (LPRM), vegetation optical depth (VOD) as well as surface soil moisture (SM) can be retrieved simultaneously from brightness temperature observations from the Advanced Mi...

  18. Effect of time spacing on the perceived color

    NASA Astrophysics Data System (ADS)

    Roch, Sylvain; Hardeberg, Jon Y.; Nussbaum, Peter

    2007-01-01

    One of latest developments for pre-press applications is the concept of soft proofing, which aims to provide an accurate preview on a monitor of how the final document will appear once it is printed. At the core of this concept is the problem of identifying, for any printed color, the most similar color the monitor can display. This problem is made difficult by such factors as varying viewing conditions, color gamut limitations, or the less studied time spacing. Color matching experiments are usually done by examining samples viewed simultaneously. However, in soft proofing applications, the proof and the print are not always viewed together. This paper attempts to shed more light on the difference between simultaneous and time-spaced color matching, in order to contribute to improving the accuracy of soft proofs. A color matching experiment setup has been established in which observers were asked to match a color patch displayed on a LCD monitor, by adjusting its RGB values, to another color patch printed out on paper. In the first part of the experiment the two colors were viewed simultaneously. In the second part, the observers were asked to produce the match according to a previously memorized color. According to the obtained results, the color appearance attributes lightness and chroma were the most difficult components for the observers to remember, generating huge differences with the simultaneous match, whereas hue was the component which varied the least. This indicates that for soft proofing, getting the hues right is of primordial importance.

  19. Simultaneous determination of 13 fluoroquinolone and 22 sulfonamide residues in milk by a dual-colorimetric enzyme-linked immunosorbent assay

    USDA-ARS?s Scientific Manuscript database

    Enzyme-linked immunosorbent assays (ELISAs) usually focus on the detection of a single analyte or a single group of analytes, e.g., fluoroquinolones or sulfonamides. However, it is often necessary to simultaneously monitor the two classes of antimicrobial residues in different food matrices. In th...

  20. Monitoring MRK 509: The Origin of the Reprocessor and Broad Band X-ray Spectrum of Narrow Line Seyfert 1 AKN 564

    NASA Technical Reports Server (NTRS)

    Halpern, Jules P.; Leighly, Karen M.

    1998-01-01

    The ten monitoring observations of Mrk 509 were made successfully between October 20 and November 26 last year. These observations were simultaneously with RXTE observations. A preliminary analysis of the RXTE observations has been done, and the light curve is shown in figure 1. Our aim in this experiment is to determine the location of the emission region of the reflection component by reverberation mapping. This component could be emitted from the accretion disk, within 100 Scwartzschild radii (R(sub s)) from the source. Note that the monitoring interval of 2.5 days corresponds to 100 R(sub s) for a 2 x 10(exp 8) solar mass black hole, which may be appropriate for this luminous object. In that case, we would expect the reflected component to vary along the direct flux, and there should be no spectral variability between observations. Alternatively, the reflected emission could come from the molecular torus, several parsecs from the nucleus. In that case, the reflection component flux should not vary. The light curve in figure 1 shows that during the monitoring period, the target varied in an ideal way, since significant variability was observed between observations and yet the most rapid variability is apparently sampled. The analysis of this data is not yet completed. The measurement of the reflection component in the combined ASCa and RXTE spectra depends critically on the RXTE background subtraction and calibration, but these have not yet progressed to the point where the analysis can be done.

  1. Comprehensive study of solid pharmaceutical tablets in visible, near infrared (NIR), and longwave infrared (LWIR) spectral regions using a rapid simultaneous ultraviolet/visible/NIR (UVN) + LWIR laser-induced breakdown spectroscopy linear arrays detection system and a fast acousto-optic tunable filter NIR spectrometer.

    PubMed

    Yang, Clayton S C; Jin, Feng; Swaminathan, Siva R; Patel, Sita; Ramer, Evan D; Trivedi, Sudhir B; Brown, Ei E; Hommerich, Uwe; Samuels, Alan C

    2017-10-30

    This is the first report of a simultaneous ultraviolet/visible/NIR and longwave infrared laser-induced breakdown spectroscopy (UVN + LWIR LIBS) measurement. In our attempt to study the feasibility of combining the newly developed rapid LWIR LIBS linear array detection system to existing rapid analytical techniques for a wide range of chemical analysis applications, two different solid pharmaceutical tablets, Tylenol arthritis pain and Bufferin, were studied using both a recently designed simultaneous UVN + LWIR LIBS detection system and a fast AOTF NIR (1200 to 2200 nm) spectrometer. Every simultaneous UVN + LWIR LIBS emission spectrum in this work was initiated by one single laser pulse-induced micro-plasma in the ambient air atmosphere. Distinct atomic and molecular LIBS emission signatures of the target compounds measured simultaneously in UVN (200 to 1100 nm) and LWIR (5.6 to 10 µm) spectral regions are readily detected and identified without the need to employ complex data processing. In depth profiling studies of these two pharmaceutical tablets without any sample preparation, one can easily monitor the transition of the dominant LWIR emission signatures from coating ingredients gradually to the pharmaceutical ingredients underneath the coating. The observed LWIR LIBS emission signatures provide complementary molecular information to the UVN LIBS signatures, thus adding robustness to identification procedures. LIBS techniques are more surface specific while NIR spectroscopy has the capability to probe more bulk materials with its greater penetration depth. Both UVN + LWIR LIBS and NIR absorption spectroscopy have shown the capabilities of acquiring useful target analyte spectral signatures in comparable short time scales. The addition of a rapid LWIR spectroscopic probe to these widely used optical analytical methods, such as NIR spectroscopy and UVN LIBS, may greatly enhance the capability and accuracy of the combined system for a comprehensive analysis.

  2. Simultaneous quantitative determination of multiple bioactive markers in Ocimum sanctum obtained from different locations and its marketed herbal formulations using UPLC-ESI-MS/MS combined with principal component analysis.

    PubMed

    Pandey, Renu; Chandra, Preeti; Srivastava, Mukesh; Mishra, D K; Kumar, Brijesh

    2015-01-01

    Ocimum sanctum L., with phenolic acids, flavonoids, propenyl phenols and terpenoids as active pharmacological constituents, is a popular medicinal herb and is present as an ingredient in many herbal formulations. Therefore, development of a reliable analytical method for simultaneous determination of the pharmacologically active constituents of O. sanctum is of high importance. To develop and validate a new, rapid, sensitive and selective UPLC-ESI/MS/MS method for simultaneous determination of 23 bioactive markers including phenolic acids, flavonoids, propenyl phenol and terpenoid in the leaf extract and marketed herbal formulations of O. sanctum. An UPLC-ESI/MS/MS method using negative electrospray ionisation (ESI) in multiple-reaction-monitoring (MRM) mode was used for simultaneous determination. Chromatographic separation was achieved on an Acquity UPLC BEH C18 -column using a gradient elution with 0.1% formic acid in water and 0.1% formic acid in acetonitrile. Principal component analysis (PCA) was applied to correlate and discriminate eight geographical collections of O. sanctum based on quantitative data of the analytes. The developed method was validated as per International Conference on Harmonization guidelines and found to be accurate, with overall recovery in the range 95.09-104.84% (RSD ≤ 1.85%), precise (RSD ≤ 1.98%) and linear (r(2)  ≥ 0.9971) over the concentration range of 0.5-1000 ng/mL. Ursolic acid was found to be the most abundant marker in all the samples investigated, except for the marketed tablet. The method established is simple, rapid and sensitive, hence it can be reliably utilised for the quality control of O. sanctum and derived herbal formulations. Copyright © 2015 John Wiley & Sons, Ltd.

  3. Validation of a Rapid and Sensitive UPLC–MS-MS Method Coupled with Protein Precipitation for the Simultaneous Determination of Seven Pyrethroids in 100 µL of Rat Plasma by Using Ammonium Adduct as Precursor Ion

    PubMed Central

    Singh, Sheelendra Pratap; Dwivedi, Nistha; Raju, Kanumuri Siva Rama; Taneja, Isha; Wahajuddin, Mohammad

    2016-01-01

    United States Environmental Protection Agency has recommended estimating pyrethroids’ risk using cumulative exposure. For cumulative risk assessment, it would be useful to have a bioanalytical method for quantification of one or several pyrethroids simultaneously in a small sample volume to support toxicokinetic studies. Therefore, in the present study, a simple, sensitive and high-throughput ultraperformance liquid chromatography–tandem mass spectrometry method was developed and validated for simultaneous analysis of seven pyrethroids (fenvalerate, fenpropathrin, bifenthrin, lambda-cyhalothrin, cyfluthrin, cypermethrin and deltamethrin) in 100 µL of rat plasma. A simple single-step protein precipitation method was used for the extraction of target compounds. The total chromatographic run time of the method was 5 min. The chromatographic system used a Supelco C18 column and isocratic elution with a mobile phase consisting of methanol and 5 mM ammonium formate in the ratio of 90 : 10 (v/v). Mass spectrometer (API 4000) was operated in multiple reaction monitoring positive-ion mode using the electrospray ionization technique. The calibration curves were linear in the range of 7.8–2,000 ng/mL with correlation coefficients of ≥0.99. All validation parameters such as precision, accuracy, recovery, matrix effect and stability met the acceptance criteria according to the regulatory guidelines. The method was successfully applied to the toxicokinetic study of cypermethrin in rats. To the best of our knowledge, this is the first LC–MS-MS method for the simultaneous analysis of pyrethroids in rat plasma. This validated method with minimal modification can also be utilized for forensic and clinical toxicological applications due to its simplicity, sensitivity and rapidity. PMID:26801239

  4. Hyperacute Simultaneous Cardiocerebral Infarction: Rescuing the Brain or the Heart First?

    PubMed

    Kijpaisalratana, Naruchorn; Chutinet, Aurauma; Suwanwela, Nijasri C

    2017-01-01

    Concurrent acute ischemic stroke and acute myocardial infarction is an uncommon medical emergency condition. The challenge for the physicians regarding the management of this situation is paramount since early management of one condition will inevitably delay the other. We present two illustrative cases of "hyperacute simultaneous cardiocerebral infarction" who presented with simultaneous cardiocerebral infarction and arrived at the hospital within the thrombolytic therapeutic window for acute ischemic stroke of 4.5 h. We propose an algorithm for managing the patient with hyperacute simultaneous cardiocerebral infarction based on hemodynamic status and suggest close cardiac monitoring based on the site of cerebral infarction.

  5. A biofilm microreactor system for simultaneous electrochemical and nuclear magnetic resonance techniques.

    PubMed

    Renslow, R S; Babauta, J T; Majors, P D; Mehta, H S; Ewing, R J; Ewing, T W; Mueller, K T; Beyenal, H

    2014-01-01

    Nuclear magnetic resonance (NMR) techniques are ideally suited for the study of biofilms and for probing their microenvironments because these techniques allow for noninvasive interrogation and in situ monitoring with high resolution. By combining NMR with simultaneous electrochemical techniques, it is possible to sustain and study live biofilms respiring on electrodes. Here, we describe a biofilm microreactor system, including a reusable and a disposable reactor, that allows for simultaneous electrochemical and NMR techniques (EC-NMR) at the microscale. Microreactors were designed with custom radio frequency resonator coils, which allowed for NMR measurements of biofilms growing on polarized gold electrodes. For an example application of this system we grew Geobacter sulfurreducens biofilms on electrodes. EC-NMR was used to investigate growth medium flow velocities and depth-resolved acetate concentration inside the biofilm. As a novel contribution we used Monte Carlo error analysis to estimate the standard deviations of the acetate concentration measurements. Overall, we found that the disposable EC-NMR microreactor provided a 9.7 times better signal-to-noise ratio over the reusable reactor. The EC-NMR biofilm microreactor system can ultimately be used to correlate extracellular electron transfer rates with metabolic reactions and explore extracellular electron transfer mechanisms.

  6. Simultaneous sonication-assisted extraction, and determination by gas chromatography-mass spectrometry, of di-(2-ethylhexyl)phthalate, nonylphenol, nonylphenol ethoxylates and polychlorinated biphenyls in sludge from wastewater treatment plants.

    PubMed

    Aparicio, I; Santos, J L; Alonso, E

    2007-02-19

    Di-(2-ethyl-hexyl)phthalate (DEHP), nonylphenol, nonylphenol mono- and diethoxylates (NPEs) and polychlorinated biphenyls (PCBs) are organic pollutants in sewage sludge which have to be monitored in the European Union according to a future Sludge Directive. In the present work, an analytical method for the simultaneous extraction and determination of DEHP, NPEs and PCBs is proposed for the routine analysis of these compounds in sludge from wastewater treatment plants. All the compounds were simultaneously extracted by sonication with hexane and analysed by gas chromatography-mass spectrometry (GC-MS) in electronic impact mode. Recoveries achieved were 105% for DEHP, 61.4-88.6% for NPEs and 55.8-108.3% for PCBs with relative standard deviation bellow 10%. Limits of quantification were 65 microg kg(-1) for DEHP, from 630 to 2504 microg kg(-1) for NPEs and from 5.4 to 10.6 microg kg(-1) for PCBs in dried sludge. The applicability of the proposed method was evaluated by the determination of these compounds in sludge from wastewater treatment plants in Seville (South Spain).

  7. Technical Report of Successful Deployment of Tandem Visual Tracking During Live Laparoscopic Cholecystectomy Between Novice and Expert Surgeon

    PubMed Central

    Baronia, Benedicto C

    2016-01-01

    With the recent advances in eye tracking technology, it is now possible to track surgeons’ eye movements while engaged in a surgical task or when surgical residents practice their surgical skills. Several studies have compared eye movements of surgical experts and novices and developed techniques to assess surgical skill on the basis of eye movement utilizing simulators and live surgery. None have evaluated simultaneous visual tracking between an expert and a novice during live surgery. Here, we describe a successful simultaneous deployment of visual tracking of an expert and a novice during live laparoscopic cholecystectomy. One expert surgeon and one chief surgical resident at an accredited surgical program in Lubbock, TX, USA performed a live laparoscopic cholecystectomy while simultaneously wearing the visual tracking devices. Their visual attitudes and movements were monitored via video recordings. The recordings were then analyzed for correlation between the expert and the novice. The visual attitudes and movements correlated approximately 85% between an expert surgeon and a chief surgical resident. The surgery was carried out uneventfully, and the data was abstracted with ease. We conclude that simultaneous deployment of visual tracking during live laparoscopic surgery is a possibility. More studies and subjects are needed to verify the success of our results and obtain data analysis. PMID:27774359

  8. Characteristics of formation and growth of atmospheric nanoparticles observed at four regional background sites in Korea

    NASA Astrophysics Data System (ADS)

    Kim, Yumi; Kim, Sang-Woo; Yoon, Soon-Chang; Park, Jin-Soo; Lim, Jae-Hyun; Hong, Jihyung; Lim, Han-Cheol; Ryu, Jegyu; Lee, Chul-Kyu; Heo, Bok-Haeng

    2016-02-01

    Measurements of the number concentration and size distribution of atmospheric nanoparticles were conducted at four sites on the west coast of the Korean Peninsula by using identical scanning mobility particle sizers (SMPSs) in October 2012. The new particle formation and subsequent growth (NPF) of atmospheric nanoparticles, which were identified by the cyclostationary empirical orthogonal function (CSEOF) analysis technique, was observed on 11 out of 21 days at the Baengnyeong-do Comprehensive Monitoring Observatory (BCMO); and on 10 out of 21 days at the Korea Global Atmosphere Watch Center (KGAWC) from October 9 to 29, 2012. We also observed NPF events for 9 out of 21 days at both the Gosan Climate Observatory (GCO) and the Jeju Comprehensive Monitoring Observatory (JCMO). During the study period, NPF was simultaneously observed for five days at all four sites, which indicates that the NPF event had a spatial extent of at least 540 km. A cold, dry and cloud-free continental air mass originated from northern China, formed favorable environmental conditions (e.g., increasing solar insolation at the surface) on simultaneous NPF at the four sites. These synoptic weather patterns were closely associated with an extraordinary typhoon passing over the south of Japan. The mean values of particle formation rates at BCMO (1.26 cm- 3 s- 1) and KGAWC (1.49 cm- 3 s- 1) were relatively higher than those at GCO (0.39 cm- 3 s- 1) and JCMO (0.74 cm- 3 s- 1), however, the growth rate showed a similar level among four sites. An increase in the spatial homogeneity and inter-site correlation of atmospheric particles among the four sites was apparent for small particles (diameter < 30 nm) on simultaneous NPF event days.

  9. US EPA Base Study Standard Operating Procedure for Continuous Monitoring of Indoor Air

    EPA Pesticide Factsheets

    The procedure described is intended for monitoring continuously and simultaneously, at selected work sites, parameters that are most commonly associated with the quality of indoor environments: the concentrations of carbon dioxide (CO2), carbon monoxide (CO), temperature, relative humidity (RH), illumination, and noise.

  10. Laboratory evaluation of dual-frequency multisensor capacitance probes to monitor soil water and salinity

    USDA-ARS?s Scientific Manuscript database

    Real-time information on salinity levels and transport of fertilizers are generally missing from soil profile knowledge bases. A dual-frequency multisensor capacitance probe (MCP) is now commercially available for sandy soils that simultaneously monitor volumetric soil water content (VWC, ') and sa...

  11. Improving streamflow prediction using remotely-sensed soil moisture and snow depth

    USDA-ARS?s Scientific Manuscript database

    The monitoring of both cold and warm season hydrologic processes in headwater watersheds is critical for accurate water resource monitoring in many alpine regions. This work presents a new method that explores the simultaneous use of remotely sensed surface soil moisture (SM) and snow depth (SD) ret...

  12. Cost-Effectiveness of Different Strategies to Monitor Adults on Antiretroviral Treatment: A Combined Analysis of Three Mathematical Models

    PubMed Central

    Keebler, Daniel; Revill, Paul; Braithwaite, Scott; Phillips, Andrew; Blaser, Nello; Borquez, Annick; Cambiano, Valentina; Ciaranello, Andrea; Estill, Janne; Gray, Richard; Hill, Andrew; Keiser, Olivia; Kessler, Jason; Menzies, Nicolas A; Nucifora, Kimberly A; Vizcaya, Luisa Salazar; Walker, Simon; Welte, Alex; Easterbrook, Philippa; Doherty, Meg; Hirnschall, Gottfried; Hallett, Timothy B

    2015-01-01

    Background The WHO’s 2013 revisions to its Consolidated Guidelines on ARVs will recommend routine viral load monitoring (VLM), rather than clinical or immunological monitoring, as the preferred monitoring approach on the basis of clinical evidence. However, HIV programmes in resource-limited settings require guidance on the most cost-effective use of resources given other competing priorities, including expansion of ART coverage. Here we assess the cost-effectiveness of alternative patient monitoring strategies. Methods A range of monitoring strategies was evaluated, including clinical, CD4 and viral load monitoring alone and together at different frequencies and with different criteria for switching to second-line therapies. Three independently-constructed and validated models were analysed simultaneously. Costs were estimated based on resource use projected in the models and associated unit costs; impact was quantified as disability-adjusted life years (DALYs) averted. Alternatives were compared using incremental cost-effectiveness analysis. Results All models show that clinical monitoring delivers significant benefit compared to a hypothetical baseline scenario with no monitoring or switching. Regular CD4 cell count monitoring confers a benefit over clinical monitoring alone, at an incremental cost that makes it affordable in more settings than VLM, which is currently more expensive. VLM without CD4 every six to 12 months provides the greatest reductions in morbidity and mortality, but incurs a high cost per DALY averted, resulting in lost opportunities to generate health gains if implemented instead of increasing ART coverage or expanding ART eligibility. Interpretation The priority for HIV programmes should be to expand ART coverage, firstly at CD4 <350 cells and then at CD4 <500, using lower-cost clinical or CD4 monitoring. At current costs, VLM should be considered only after high ART coverage has been achieved. Point-of-care technologies and other factors reducing costs may make VLM more affordable in future. Funding The HIV Modelling Consortium is funded by the Bill and Melinda Gates Foundation. Funding for this work was also provided by the World Health Organization. PMID:25104633

  13. Simultaneous multi-patch-clamp and extracellular-array recordings: Single neuron reflects network activity

    NASA Astrophysics Data System (ADS)

    Vardi, Roni; Goldental, Amir; Sardi, Shira; Sheinin, Anton; Kanter, Ido

    2016-11-01

    The increasing number of recording electrodes enhances the capability of capturing the network’s cooperative activity, however, using too many monitors might alter the properties of the measured neural network and induce noise. Using a technique that merges simultaneous multi-patch-clamp and multi-electrode array recordings of neural networks in-vitro, we show that the membrane potential of a single neuron is a reliable and super-sensitive probe for monitoring such cooperative activities and their detailed rhythms. Specifically, the membrane potential and the spiking activity of a single neuron are either highly correlated or highly anti-correlated with the time-dependent macroscopic activity of the entire network. This surprising observation also sheds light on the cooperative origin of neuronal burst in cultured networks. Our findings present an alternative flexible approach to the technique based on a massive tiling of networks by large-scale arrays of electrodes to monitor their activity.

  14. Simultaneous multi-patch-clamp and extracellular-array recordings: Single neuron reflects network activity.

    PubMed

    Vardi, Roni; Goldental, Amir; Sardi, Shira; Sheinin, Anton; Kanter, Ido

    2016-11-08

    The increasing number of recording electrodes enhances the capability of capturing the network's cooperative activity, however, using too many monitors might alter the properties of the measured neural network and induce noise. Using a technique that merges simultaneous multi-patch-clamp and multi-electrode array recordings of neural networks in-vitro, we show that the membrane potential of a single neuron is a reliable and super-sensitive probe for monitoring such cooperative activities and their detailed rhythms. Specifically, the membrane potential and the spiking activity of a single neuron are either highly correlated or highly anti-correlated with the time-dependent macroscopic activity of the entire network. This surprising observation also sheds light on the cooperative origin of neuronal burst in cultured networks. Our findings present an alternative flexible approach to the technique based on a massive tiling of networks by large-scale arrays of electrodes to monitor their activity.

  15. Simultaneous multi-patch-clamp and extracellular-array recordings: Single neuron reflects network activity

    PubMed Central

    Vardi, Roni; Goldental, Amir; Sardi, Shira; Sheinin, Anton; Kanter, Ido

    2016-01-01

    The increasing number of recording electrodes enhances the capability of capturing the network’s cooperative activity, however, using too many monitors might alter the properties of the measured neural network and induce noise. Using a technique that merges simultaneous multi-patch-clamp and multi-electrode array recordings of neural networks in-vitro, we show that the membrane potential of a single neuron is a reliable and super-sensitive probe for monitoring such cooperative activities and their detailed rhythms. Specifically, the membrane potential and the spiking activity of a single neuron are either highly correlated or highly anti-correlated with the time-dependent macroscopic activity of the entire network. This surprising observation also sheds light on the cooperative origin of neuronal burst in cultured networks. Our findings present an alternative flexible approach to the technique based on a massive tiling of networks by large-scale arrays of electrodes to monitor their activity. PMID:27824075

  16. Use of a pressure sensing sheath: comparison with standard means of blood pressure monitoring in catheterization procedures.

    PubMed

    Purdy, Phillip D; South, Charles; Klucznik, Richard P; Liu, Kenneth C; Novakovic, Robin L; Puri, Ajit S; Pride, G Lee; Aagaard-Kienitz, Beverly; Ray, Abishek; Elliott, Alan C

    2017-08-01

    Monitoring of blood pressure (BP) during procedures is variable, depending on multiple factors. Common methods include sphygmomanometer (BP cuff), separate radial artery catheterization, and side port monitoring of an indwelling sheath. Each means of monitoring has disadvantages, including time consumption, added risk, and signal dampening due to multiple factors. We sought an alternative approach to monitoring during procedures in the catheterization laboratory. A new technology involving a 330 µm fiberoptic sensor embedded in the wall of a sheath structure was tested against both radial artery catheter and sphygmomanometer readings obtained simultaneous with readings recorded from the pressure sensing system (PSS). Correlations and Bland-Altman analysis were used to determine whether use of the PSS could substitute for these standard techniques. The results indicated highly significant correlations in systolic, diastolic, and mean arterial pressures (MAP) when compared against radial artery catheterization (p<0.0001), and MAP means differed by <4%. Bland-Altman analysis of the data suggested that the sheath measurements can replace a separate radial artery catheter. While less striking, significant correlations were seen when PSS readings were compared against BP cuff readings. The PSS has competitive functionality to that seen with a dedicated radial artery catheter for BP monitoring and is available immediately on sheath insertion without the added risk of radial catheterization. The sensor is structurally separated from the primary sheath lumen and readings are unaffected by device introduction through the primary lumen. Time delays and potential complications from radial artery catheterization are avoided. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  17. Bayesian Inference for Signal-Based Seismic Monitoring

    NASA Astrophysics Data System (ADS)

    Moore, D.

    2015-12-01

    Traditional seismic monitoring systems rely on discrete detections produced by station processing software, discarding significant information present in the original recorded signal. SIG-VISA (Signal-based Vertically Integrated Seismic Analysis) is a system for global seismic monitoring through Bayesian inference on seismic signals. By modeling signals directly, our forward model is able to incorporate a rich representation of the physics underlying the signal generation process, including source mechanisms, wave propagation, and station response. This allows inference in the model to recover the qualitative behavior of recent geophysical methods including waveform matching and double-differencing, all as part of a unified Bayesian monitoring system that simultaneously detects and locates events from a global network of stations. We demonstrate recent progress in scaling up SIG-VISA to efficiently process the data stream of global signals recorded by the International Monitoring System (IMS), including comparisons against existing processing methods that show increased sensitivity from our signal-based model and in particular the ability to locate events (including aftershock sequences that can tax analyst processing) precisely from waveform correlation effects. We also provide a Bayesian analysis of an alleged low-magnitude event near the DPRK test site in May 2010 [1] [2], investigating whether such an event could plausibly be detected through automated processing in a signal-based monitoring system. [1] Zhang, Miao and Wen, Lianxing. "Seismological Evidence for a Low-Yield Nuclear Test on 12 May 2010 in North Korea". Seismological Research Letters, January/February 2015. [2] Richards, Paul. "A Seismic Event in North Korea on 12 May 2010". CTBTO SnT 2015 oral presentation, video at https://video-archive.ctbto.org/index.php/kmc/preview/partner_id/103/uiconf_id/4421629/entry_id/0_ymmtpps0/delivery/http

  18. Harmonic Motion Imaging for Abdominal Tumor Detection and High-intensity Focused Ultrasound Ablation Monitoring: A Feasibility Study in a Transgenic Mouse Model of Pancreatic Cancer

    PubMed Central

    Chen, Hong; Hou, Gary Y.; Han, Yang; Payen, Thomas; Palermo, Carmine F.; Olive, Kenneth P.; Konofagou, Elisa E.

    2015-01-01

    Harmonic motion imaging (HMI) is a radiation force-based elasticity imaging technique that tracks oscillatory tissue displacements induced by sinusoidal ultrasonic radiation force to assess relative tissue stiffness. The objective of this study was to evaluate the feasibility of HMI in pancreatic tumor detection and high-intensity focused ultrasound (HIFU) treatment monitoring. The HMI system consisted of a focused ultrasound transducer, which generated sinusoidal radiation force to induce oscillatory tissue motion at 50 Hz, and a diagnostic ultrasound transducer, which detected the axial tissue displacements based on acquired radiofrequency signals using a 1D cross-correlation algorithm. For pancreatic tumor detection, HMI images were generated for pancreatic tumors in transgenic mice and normal pancreases in wild-type mice. The obtained HMI images showed a high contrast between normal and malignant pancreases with an average peak-to-peak HMI displacement ratio of 3.2. Histological analysis showed that no tissue damage was associated with HMI when it was used for the sole purpose of elasticity imaging. For pancreatic tumor ablation monitoring, the focused ultrasound transducer was operated with a higher acoustic power and longer pulse length than that used in tumor detection to simultaneously induce HIFU thermal ablation and oscillatory tissue displacements, allowing HMI monitoring without interrupting tumor ablation. HMI monitoring of HIFU ablation found significant decreases in the peak-to-peak HMI displacements before and after HIFU ablation with a reduction rate ranging from 15.8% to 57.0%. The formation of thermal lesions after HIFU exposure was confirmed by histological analysis. This study demonstrated the feasibility of HMI in abdominal tumor detection and HIFU ablation monitoring. PMID:26415128

  19. Harmonic motion imaging for abdominal tumor detection and high-intensity focused ultrasound ablation monitoring: an in vivo feasibility study in a transgenic mouse model of pancreatic cancer.

    PubMed

    Chen, Hong; Hou, Gary Y; Han, Yang; Payen, Thomas; Palermo, Carmine F; Olive, Kenneth P; Konofagou, Elisa E

    2015-09-01

    Harmonic motion imaging (HMI) is a radiationforce- based elasticity imaging technique that tracks oscillatory tissue displacements induced by sinusoidal ultrasonic radiation force to assess the resulting oscillatory displacement denoting the underlying tissue stiffness. The objective of this study was to evaluate the feasibility of HMI in pancreatic tumor detection and high-intensity focused ultrasound (HIFU) treatment monitoring. The HMI system consisted of a focused ultrasound transducer, which generated sinusoidal radiation force to induce oscillatory tissue motion at 50 Hz, and a diagnostic ultrasound transducer, which detected the axial tissue displacements based on acquired radio-frequency signals using a 1-D cross-correlation algorithm. For pancreatic tumor detection, HMI images were generated for pancreatic tumors in transgenic mice and normal pancreases in wild-type mice. The obtained HMI images showed a high contrast between normal and malignant pancreases with an average peak-to-peak HMI displacement ratio of 3.2. Histological analysis showed that no tissue damage was associated with HMI when it was used for the sole purpose of elasticity imaging. For pancreatic tumor ablation monitoring, the focused ultrasound transducer was operated at a higher acoustic power and longer pulse length than that used in tumor detection to simultaneously induce HIFU thermal ablation and oscillatory tissue displacements, allowing HMI monitoring without interrupting tumor ablation. HMI monitoring of HIFU ablation found significant decreases in the peak-to-peak HMI displacements before and after HIFU ablation with a reduction rate ranging from 15.8% to 57.0%. The formation of thermal lesions after HIFU exposure was confirmed by histological analysis. This study demonstrated the feasibility of HMI in abdominal tumor detection and HIFU ablation monitoring.

  20. Validation of cardiac output studies from the Mostcare compared to a pulmonary artery catheter in septic patients.

    PubMed

    Gopal, S; Do, T; Pooni, J S; Martinelli, G

    2014-03-01

    The Mostcare monitor is a non-invasive cardiac output monitor. It has been well validated in cardiac surgical patients but there is limited evidence on its use in patients with severe sepsis and septic shock. The study included the first 22 consecutive patients with severe sepsis and septic shock in whom the floatation of a pulmonary artery catheter was deemed necessary to guide clinical management. Cardiac output measurements including cardiac output, cardiac index and stroke volume were simultaneously calculated and recorded from a thermodilution pulmonary artery catheter and from the Mostcare monitor respectively. The two methods of measuring cardiac output were compared by Bland-Altman statistics and linear regression analysis. A percentage error of less than 30% was defined as acceptable for this study. Bland-Altman analysis for cardiac output showed a Bias of 0.31 L.min-1, precision (=SD) of 1.97 L.min-1 and a percentage error of 62.54%. For Cardiac Index the bias was 0.21 L.min-1.m-2, precision of 1.10 L.min-1.m-2 and a percentage error of 64%. For stroke volume the bias was 5 mL, precision of 24.46 mL and percentage error of 70.21%. Linear regression produced a correlation coefficient r2 for cardiac output, cardiac index, and stroke volume, of 0.403, 0.306, and 0.3 respectively. Compared to thermodilution cardiac output, cardiac output studies obtained from the Mostcare monitor have an unacceptably high error rate. The Mostcare monitor demonstrated to be an unreliable monitoring device to measure cardiac output in patients with severe sepsis and septic shock on an intensive care unit.

  1. APPARATUS FOR MEASURING TOTAL NEUTRON CROSS SECTIONS

    DOEpatents

    Cranberg, L.

    1959-10-13

    An apparatus is described for measuring high-resolution total neutron cross sections at high counting rate in the range above 50-kev neutron energy. The pulsed-beam time-of-flight technique is used to identify the neutrons of interest which are produced in the target of an electrostatic accelerator. Energy modulation of the accelerator . makes it possible to make observations at 100 energy points simultaneously. 761O An apparatus is described for monitoring the proton resonance of a liquid which is particulariy useful in the continuous purity analysis of heavy water. A hollow shell with parallel sides defines a meander chamber positioned within a uniform magnetic fieid. The liquid passes through an inlet at the outer edge of the chamber and through a spiral channel to the central region of the chamber where an outlet tube extends into the chamber perpendicular to the magnetic field. The radiofrequency energy for the monitor is coupled to a coil positioned coaxially with the outlet tube at its entrance point within the chamber. The improvement lies in the compact mechanical arrangement of the monitor unit whereby the liquid under analysis is subjected to the same magnetic field in the storage and sensing areas, and the entire unit is shielded from external electrostatic influences.

  2. Laboratory and field based evaluation of chromatography ...

    EPA Pesticide Factsheets

    The Monitor for AeRosols and GAses in ambient air (MARGA) is an on-line ion-chromatography-based instrument designed for speciation of the inorganic gas and aerosol ammonium-nitrate-sulfate system. Previous work to characterize the performance of the MARGA has been primarily based on field comparison to other measurement methods to evaluate accuracy. While such studies are useful, the underlying reasons for disagreement among methods are not always clear. This study examines aspects of MARGA accuracy and precision specifically related to automated chromatography analysis. Using laboratory standards, analytical accuracy, precision, and method detection limits derived from the MARGA chromatography software are compared to an alternative software package (Chromeleon, Thermo Scientific Dionex). Field measurements are used to further evaluate instrument performance, including the MARGA’s use of an internal LiBr standard to control accuracy. Using gas/aerosol ratios and aerosol neutralization state as a case study, the impact of chromatography on measurement error is assessed. The new generation of on-line chromatography-based gas and particle measurement systems have many advantages, including simultaneous analysis of multiple pollutants. The Monitor for Aerosols and Gases in Ambient Air (MARGA) is such an instrument that is used in North America, Europe, and Asia for atmospheric process studies as well as routine monitoring. While the instrument has been evaluat

  3. Time and number of displays impact critical signal detection in fetal heart rate tracings.

    PubMed

    Anderson, Brittany L; Scerbo, Mark W; Belfore, Lee A; Abuhamad, Alfred Z

    2011-06-01

    Interest in centralized monitoring in labor and delivery units is growing because it affords the opportunity to monitor multiple patients simultaneously. However, a long history of research on sustained attention reveals these types of monitoring tasks can be problematic. The goal of the present experiment was to examine the ability of individuals to detect critical signals in fetal heart rate (FHR) tracings in one or more displays over an extended period of time. Seventy-two participants monitored one, two, or four computer-simulated FHR tracings on a computer display for the appearance of late decelerations over a 48-minute vigil. Measures of subjective stress and workload were also obtained before and after the vigil. The results showed that detection accuracy decreased over time and also declined as the number of displays increased. The subjective reports indicated that participants found the task to be stressful and mentally demanding, effortful, and frustrating. The results suggest that centralized monitoring that allows many patients to be monitored simultaneously may impose a detrimental attentional burden on the observer. Furthermore, this seemingly benign task may impose an additional source of stress and mental workload above what is commonly found in labor and delivery units. © Thieme Medical Publishers.

  4. A smart health monitoring chair for nonintrusive measurement of biological signals.

    PubMed

    Baek, Hyun Jae; Chung, Gih Sung; Kim, Ko Keun; Park, Kwang Suk

    2012-01-01

    We developed nonintrusive methods for simultaneous electrocardiogram, photoplethysmogram, and ballistocardiogram measurements that do not require direct contact between instruments and bare skin. These methods were applied to the design of a diagnostic chair for unconstrained heart rate and blood pressure monitoring purposes. Our methods were operationalized through capacitively coupled electrodes installed in the chair back that include high-input impedance amplifiers, and conductive textiles installed in the seat for capacitive driven-right-leg circuit configuration that is capable of recording electrocardiogram information through clothing. Photoplethysmograms were measured through clothing using seat mounted sensors with specially designed amplifier circuits that vary in light intensity according to clothing type. Ballistocardiograms were recorded using a film type transducer material, polyvinylidenefluoride (PVDF), which was installed beneath the seat cover. By simultaneously measuring signals, beat-to-beat heart rates could be monitored even when electrocardiograms were not recorded due to movement artifacts. Beat-to-beat blood pressure was also monitored using unconstrained measurements of pulse arrival time and other physiological parameters, and our experimental results indicated that the estimated blood pressure tended to coincide with actual blood pressure measurements. This study demonstrates the feasibility of our method and device for biological signal monitoring through clothing for unconstrained long-term daily health monitoring that does not require user awareness and is not limited by physical activity.

  5. Simultaneous, noninvasive, in vivo, continuous monitoring of hematocrit, vascular volume, hemoglobin oxygen saturation, pulse rate and breathing rate in humans and other animal models using a single light source

    NASA Astrophysics Data System (ADS)

    Dent, Paul; Tun, Sai Han; Fillioe, Seth; Deng, Bin; Satalin, Josh; Nieman, Gary; Wilcox, Kailyn; Searles, Quinn; Narsipur, Sri; Peterson, Charles M.; Goodisman, Jerry; Mostrom, James; Steinmann, Richard; Chaiken, J.

    2018-02-01

    We previously reported a new algorithm "PV[O]H" for continuous, noninvasive, in vivo monitoring of hematocrit changes in blood and have since shown its utility for monitoring in humans during 1) hemodialysis, 2) orthostatic perturbations and 3) during blood loss and fluid replacement in a rat model. We now show that the algorithm is sensitive to changes in hemoglobin oxygen saturation. We document the phenomenology of the effect and explain the effect using new results obtained from humans and rat models. The oxygen sensitivity derives from the differential absorption of autofluorescence originating in the static tissues by oxy and deoxy hemoglobin. Using this approach we show how to perform simultaneous, noninvasive, in vivo, continuous monitoring of hematocrit, vascular volume, hemoglobin oxygen saturation, pulse rate and breathing rate in mammals using a single light source. We suspect that monitoring of changes in this suite of vital signs can be provided with improved time response, sensitivity and precision compared to existing methodologies. Initial results also offer a more detailed glimpse into the systemic oxygen transport in the circulatory system of humans.

  6. Simultaneous recording of EEG and electromyographic polygraphy increases the diagnostic yield of video-EEG monitoring.

    PubMed

    Hill, Aron T; Briggs, Belinda A; Seneviratne, Udaya

    2014-06-01

    To investigate the usefulness of adjunctive electromyographic (EMG) polygraphy in the diagnosis of clinical events captured during long-term video-EEG monitoring. A total of 40 patients (21 women, 19 men) aged between 19 and 72 years (mean 43) investigated using video-EEG monitoring were studied. Electromyographic activity was simultaneously recorded with EEG in four patients selected on clinical grounds. In these patients, surface EMG electrodes were placed over muscles suspected to be activated during a typical clinical event. Of the 40 patients investigated, 24 (60%) were given a diagnosis, whereas 16 (40%) remained undiagnosed. All four patients receiving adjunctive EMG polygraphy obtained a diagnosis, with three of these diagnoses being exclusively reliant on the EMG recordings. Specifically, one patient was diagnosed with propriospinal myoclonus, another patient was diagnosed with facio-mandibular myoclonus, and a third patient was found to have bruxism and periodic leg movements of sleep. The information obtained from surface EMG recordings aided the diagnosis of clinical events captured during video-EEG monitoring in 7.5% of the total cohort. This study suggests that EEG-EMG polygraphy may be used as a technique of improving the diagnostic yield of video-EEG monitoring in selected cases.

  7. Portable Video/Digital Retinal Funduscope

    NASA Technical Reports Server (NTRS)

    Taylor, Gerald R.; Meehan, Richard; Hunter, Norwood; Caputo, Michael; Gibson, C. Robert

    1991-01-01

    Lightweight, inexpensive electronic and photographic instrument developed for detection, monitoring, and objective quantification of ocular/systemic disease or physiological alterations of retina, blood vessels, or other structures in anterior and posterior chambers of eye. Operated with little training. Functions with human or animal subject seated, recumbent, inverted, or in almost any other orientation; and in hospital, laboratory, field, or other environment. Produces video images viewed directly and/or digitized for simultaneous or subsequent analysis. Also equipped to produce photographs and/or fitted with adaptors to produce stereoscopic or magnified images of skin, nose, ear, throat, or mouth to detect lesions or diseases.

  8. Lithographically fabricated silicon microreactor for operando QEXAFS studies in exhaust gas catalysis during simulation of a standard driving cycle

    NASA Astrophysics Data System (ADS)

    Doronkin, D. E.; Baier, S.; Sheppard, T.; Benzi, F.; Grunwaldt, J.-D.

    2016-05-01

    Selective catalytic reduction of NOx by ammonia over Cu-ZSM-5 was monitored by operando QEXAFS during simulation of the New European Driving Cycle. The required fast temperature transients were realized using a novel silicon microreactor, enabling simultaneous spectroscopic and kinetic analysis by X-ray absorption spectroscopy (XAS) and mass spectrometry (MS). Periods of high temperature were correlated to an increase in both N2 production and change of coordination of Cu sites. This operando approach using Si microreactors can be applied to other heterogeneous catalytic systems involving fast temperature transients.

  9. PCA Based Stress Monitoring of Cylindrical Specimens Using PZTs and Guided Waves

    PubMed Central

    Mujica, Luis; Ruiz, Magda; Camacho, Johanatan

    2017-01-01

    Since mechanical stress in structures affects issues such as strength, expected operational life and dimensional stability, a continuous stress monitoring scheme is necessary for a complete integrity assessment. Consequently, this paper proposes a stress monitoring scheme for cylindrical specimens, which are widely used in structures such as pipelines, wind turbines or bridges. The approach consists of tracking guided wave variations due to load changes, by comparing wave statistical patterns via Principal Component Analysis (PCA). Each load scenario is projected to the PCA space by means of a baseline model and represented using the Q-statistical indices. Experimental validation of the proposed methodology is conducted on two specimens: (i) a 12.7 mm (1/2″) diameter, 0.4 m length, AISI 1020 steel rod, and (ii) a 25.4 mm (1″) diameter, 6m length, schedule 40, A-106, hollow cylinder. Specimen 1 was subjected to axial loads, meanwhile specimen 2 to flexion. In both cases, simultaneous longitudinal and flexural guided waves were generated via piezoelectric devices (PZTs) in a pitch-catch configuration. Experimental results show the feasibility of the approach and its potential use as in-situ continuous stress monitoring application. PMID:29194384

  10. The validity of activity monitors for measuring sleep in elite athletes.

    PubMed

    Sargent, Charli; Lastella, Michele; Halson, Shona L; Roach, Gregory D

    2016-10-01

    There is a growing interest in monitoring the sleep of elite athletes. Polysomnography is considered the gold standard for measuring sleep, however this technique is impractical if the aim is to collect data simultaneously with multiple athletes over consecutive nights. Activity monitors may be a suitable alternative for monitoring sleep, but these devices have not been validated against polysomnography in a population of elite athletes. Participants (n=16) were endurance-trained cyclists participating in a 6-week training camp. A total of 122 nights of sleep were recorded with polysomnography and activity monitors simultaneously. Agreement, sensitivity, and specificity were calculated from epoch-for-epoch comparisons of polysomnography and activity monitor data. Sleep variables derived from polysomnography and activity monitors were compared using paired t-tests. Activity monitor data were analysed using low, medium, and high sleep-wake thresholds. Epoch-for-epoch comparisons showed good agreement between activity monitors and polysomnography for each sleep-wake threshold (81-90%). Activity monitors were sensitive to sleep (81-92%), but specificity differed depending on the threshold applied (67-82%). Activity monitors underestimated sleep duration (18-90min) and overestimated wake duration (4-77min) depending on the threshold applied. Applying the correct sleep-wake threshold is important when using activity monitors to measure the sleep of elite athletes. For example, the default sleep-wake threshold (>40 activity counts=wake) underestimates sleep duration by ∼50min and overestimates wake duration by ∼40min. In contrast, sleep-wake thresholds that have a high sensitivity to sleep (>80 activity counts=wake) yield the best combination of agreement, sensitivity, and specificity. Copyright © 2015 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  11. The automated counting of beating rates in individual cultured heart cells.

    PubMed

    Collins, G A; Dower, R; Walker, M J

    1981-12-01

    The effect of drugs on the beating rate of cultured heart cells can be monitored in a number of ways. The simultaneous automated measurement of beating rates of a number of cells allows drug effects to be rapidly quantified. A photoresistive detector placed on a television image of a cell, when coupled to operational amplifiers, gives binary signals that can be processed by a microprocessor. On this basis, we have devised a system that is capable of simultaneously monitoring the individual beating of six single cultured heart cells. A microprocessor automatically processes data obtained under different experimental conditions and records it in suitable descriptive formats such as dose-response curves and double reciprocal plots.

  12. A-TEEMTM, a new molecular fingerprinting technique: simultaneous absorbance-transmission and fluorescence excitation-emission matrix method

    NASA Astrophysics Data System (ADS)

    Quatela, Alessia; Gilmore, Adam M.; Steege Gall, Karen E.; Sandros, Marinella; Csatorday, Karoly; Siemiarczuk, Alex; (Ben Yang, Boqian; Camenen, Loïc

    2018-04-01

    We investigate the new simultaneous absorbance-transmission and fluorescence excitation-emission matrix method for rapid and effective characterization of the varying components from a mixture. The absorbance-transmission and fluorescence excitation-emission matrix method uniquely facilitates correction of fluorescence inner-filter effects to yield quantitative fluorescence spectral information that is largely independent of component concentration. This is significant because it allows one to effectively monitor quantitative component changes using multivariate methods and to generate and evaluate spectral libraries. We present the use of this novel instrument in different fields: i.e. tracking changes in complex mixtures including natural water, wine as well as monitoring stability and aggregation of hormones for biotherapeutics.

  13. Simultaneous determination of eight chemicals in Fufang Xueshuantong capsules by LC-MS-MS with periodic polarity switching.

    PubMed

    Zhou, Chunhua; Su, Linfei; Shang, Weiding; Rong, Zhihuan; Sun, Mengmeng; Zhang, Kai; Shi, Xiaowei; Wang, Qiao

    2015-01-01

    A rapid, sensitive, selective and periodic polarity-switching liquid chromatography-tandem mass spectrometry(LC-MS-MS) method was developed for the simultaneous determination of eight components in an important traditional Chinese medicinal capsule, Fufang Xueshuantong. LC analysis was carried out on a Kinetex 2.6 µm XB-C18 column by gradient elution. The detection was performed by multiple reaction monitoring (MRM) with a periodic polarity-switching electrospray ionization (ESI) source across five periods of switching between positive and negative mode. Periodic polarity-switching was used to acquire maximal responses and to simultaneously detect eight constituents in one analysis run lasting 8 min. All of the analytes showed good linearity (r > 0.9947) in the tested ranges. The average recoveries were in the range of 95.4-103.9% with relative standard deviations ≤6.3%, and the intra- and inter-day variations were ≤3.7%. The developed method was successfully employed to analyze three batches of Fufang Xueshuantong capsule samples. The results showed that the levels of notoginsenoside R1, ginsenoside Rb1 and salvianolic acid B were clearly different in different batches of Fufang Xueshuantong capsules. Furthermore, the new established periodic polarity-switching LC-MS-MS method was proven to be highly sensitive and effective in evaluating the quality of Fufang Xueshuantong capsules. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. Artificial neural network assisted kinetic spectrophotometric technique for simultaneous determination of paracetamol and p-aminophenol in pharmaceutical samples using localized surface plasmon resonance band of silver nanoparticles

    NASA Astrophysics Data System (ADS)

    Khodaveisi, Javad; Dadfarnia, Shayessteh; Haji Shabani, Ali Mohammad; Rohani Moghadam, Masoud; Hormozi-Nezhad, Mohammad Reza

    2015-03-01

    Spectrophotometric analysis method based on the combination of the principal component analysis (PCA) with the feed-forward neural network (FFNN) and the radial basis function network (RBFN) was proposed for the simultaneous determination of paracetamol (PAC) and p-aminophenol (PAP). This technique relies on the difference between the kinetic rates of the reactions between analytes and silver nitrate as the oxidizing agent in the presence of polyvinylpyrrolidone (PVP) which is the stabilizer. The reactions are monitored at the analytical wavelength of 420 nm of the localized surface plasmon resonance (LSPR) band of the formed silver nanoparticles (Ag-NPs). Under the optimized conditions, the linear calibration graphs were obtained in the concentration range of 0.122-2.425 μg mL-1 for PAC and 0.021-5.245 μg mL-1 for PAP. The limit of detection in terms of standard approach (LODSA) and upper limit approach (LODULA) were calculated to be 0.027 and 0.032 μg mL-1 for PAC and 0.006 and 0.009 μg mL-1 for PAP. The important parameters were optimized for the artificial neural network (ANN) models. Statistical parameters indicated that the ability of the both methods is comparable. The proposed method was successfully applied to the simultaneous determination of PAC and PAP in pharmaceutical preparations.

  15. Daylighting performance and thermal implications of skylights vs. south-facing roof monitors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosenbaum, M.; Coldham, B.

    1997-12-31

    This paper reports the results of a comparison of skylights vs. south-facing roof monitors for daylighting the north wall zone of a 10,000 ft{sup 2} office building near Manchester, NH. A physical model was constructed and tested. Simultaneously, the building`s annual thermal performance was modeled with Energy-10 hourly simulation software, and its peak heating and cooling load performance was modeled with the Carrier Corp. Hourly Analysis Program (HAP). Apertures were built into the roof of the model, and several skylight and south-facing roof monitor configurations were tested in both clear and overcast conditions. A design goal was to have themore » building be daylit on overcast as well as clear days. This goal was based more on enhancement of the working environment than it was on electrical energy savings. Monitors with overhangs performed poorly in the overcast conditions--it was determined that 2.4 times as much monitor aperture was needed to yield equivalent light levels in overcast conditions. The thermal models showed that the annual heating and cooling energy cost for the building was the same for either strategy, but that peak cooling loads and peak heating loads were lower with the skylit version. The authors concluded that skylights were preferred over monitors in this application, due to similar annual energy costs, lower peak loads, and lower construction cost.« less

  16. Enhanced Raman Monitor Project

    NASA Technical Reports Server (NTRS)

    Westenskow, Dwayne

    1996-01-01

    Monitoring of gaseous contaminants stems from the need to ensure a healthy and safe environment. NASA/Ames needs sensors that are able to monitor common atmospheric gas concentrations as well as trace amounts of contaminant gases. To provide an accurate assessment of air quality, a monitoring system would need to be continuous and on-line with full spectrum capabilities, allowing simultaneous detection of all gas components in a sample, including both combustible and non-combustible gases. The system demands a high degree of sensitivity to detect low gas concentrations in the low-ppm and sub-ppm regions. For clean and healthy air ('good' category), criteria established by the EPA requires that contaminant concentrations not exceed 4 ppm of carbon monoxide (CO) in an 8 hour period, 60 ppb of ozone(O3) in a one hour period and 30 ppb of sulfur dioxide (SO2) in a 24 hour period. One step below this is the National Ambient Air Quality Standard ('moderate' category) which requires that contaminant concentrations not exceed 9 ppm of carbon monoxide (CO), 120 ppb of ozone (O3) and 140 ppb of sulfur dioxide (SO2) for their respective time periods. Ideally a monitor should be able to detect the concentrations specified in the 'good' category. To benchmark current abilities of Raman technology in gas phase analysis, laboratory experiments were performed to evaluate the RASCAL II anesthetic gas monitor.

  17. Multicriteria relocation analysis of an off-site radioactive monitoring network for a nuclear power plant.

    PubMed

    Chang, Ni-Bin; Ning, Shu-Kuang; Chen, Jen-Chang

    2006-08-01

    Due to increasing environmental consciousness in most countries, every utility that owns a commercial nuclear power plant has been required to have both an on-site and off-site emergency response plan since the 1980s. A radiation monitoring network, viewed as part of the emergency response plan, can provide information regarding the radiation dosage emitted from a nuclear power plant in a regular operational period and/or abnormal measurements in an emergency event. Such monitoring information might help field operators and decision-makers to provide accurate responses or make decisions to protect the public health and safety. This study aims to conduct an integrated simulation and optimization analysis looking for the relocation strategy of a long-term regular off-site monitoring network at a nuclear power plant. The planning goal is to downsize the current monitoring network but maintain its monitoring capacity as much as possible. The monitoring sensors considered in this study include the thermoluminescence dosimetry (TLD) and air sampling system (AP) simultaneously. It is designed for detecting the radionuclide accumulative concentration, the frequency of violation, and the possible population affected by a long-term impact in the surrounding area regularly while it can also be used in an accidental release event. With the aid of the calibrated Industrial Source Complex-Plume Rise Model Enhancements (ISC-PRIME) simulation model to track down the possible radionuclide diffusion, dispersion, transport, and transformation process in the atmospheric environment, a multiobjective evaluation process can be applied to achieve the screening of monitoring stations for the nuclear power plant located at Hengchun Peninsula, South Taiwan. To account for multiple objectives, this study calculated preference weights to linearly combine objective functions leading to decision-making with exposure assessment in an optimization context. Final suggestions should be useful for narrowing the set of scenarios that decision-makers need to consider in this relocation process.

  18. Quantitative 31P NMR for Simultaneous Trace Analysis of Organophosphorus Pesticides in Aqueous Media Using the Stir Bar Sorptive Extraction Method

    NASA Astrophysics Data System (ADS)

    Ansari, S.; Talebpour, Z.; Molaabasi, F.; Bijanzadeh, H. R.; Khazaeli, S.

    2016-09-01

    The analysis of pesticides in water samples is of primary concern for quality control laboratories due to the toxicity of these compounds and their associated public health risk. A novel analytical method based on stir bar sorptive extraction (SBSE), followed by 31P quantitative nuclear magnetic resonance (31P QNMR), has been developed for simultaneously monitoring and determining four organophosphorus pesticides (OPPs) in aqueous media. The effects of factors on the extraction efficiency of OPPs were investigated using a Draper-Lin small composite design. An optimal sample volume of 4.2 mL, extraction time of 96 min, extraction temperature of 42°C, and desorption time of 11 min were obtained. The results showed reasonable linearity ranges for all pesticides with correlation coefficients greater than 0.9920. The limit of quantification (LOQ) ranged from 0.1 to 2.60 mg/L, and the recoveries of spiked river water samples were from 82 to 94% with relative standard deviation (RSD) values less than 4%. The results show that this method is simple, selective, rapid, and can be applied to other sample matrices.

  19. Low level radioactivity measurements with phoswich detectors using coincident techniques and digital pulse processing analysis.

    PubMed

    de la Fuente, R; de Celis, B; del Canto, V; Lumbreras, J M; de Celis Alonso, B; Martín-Martín, A; Gutierrez-Villanueva, J L

    2008-10-01

    A new system has been developed for the detection of low radioactivity levels of fission products and actinides using coincidence techniques. The device combines a phoswich detector for alpha/beta/gamma-ray recognition with a fast digital card for electronic pulse analysis. The phoswich can be used in a coincident mode by identifying the composed signal produced by the simultaneous detection of alpha/beta particles and X-rays/gamma particles. The technique of coincidences with phoswich detectors was proposed recently to verify the Nuclear Test Ban Treaty (NTBT) which established the necessity of monitoring low levels of gaseous fission products produced by underground nuclear explosions. With the device proposed here it is possible to identify the coincidence events and determine the energy and type of coincident particles. The sensitivity of the system has been improved by employing liquid scintillators and a high resolution low energy germanium detector. In this case it is possible to identify simultaneously by alpha/gamma coincidence transuranic nuclides present in environmental samples without necessity of performing radiochemical separation. The minimum detectable activity was estimated to be 0.01 Bq kg(-1) for 0.1 kg of soil and 1000 min counting.

  20. Using SFOC to fly the Magellan Venus mapping mission

    NASA Technical Reports Server (NTRS)

    Bucher, Allen W.; Leonard, Robert E., Jr.; Short, Owen G.

    1993-01-01

    Traditionally, spacecraft flight operations at the Jet Propulsion Laboratory (JPL) have been performed by teams of spacecraft experts utilizing ground software designed specifically for the current mission. The Jet Propulsion Laboratory set out to reduce the cost of spacecraft mission operations by designing ground data processing software that could be used by multiple spacecraft missions, either sequentially or concurrently. The Space Flight Operations Center (SFOC) System was developed to provide the ground data system capabilities needed to monitor several spacecraft simultaneously and provide enough flexibility to meet the specific needs of individual projects. The Magellan Spacecraft Team utilizes the SFOC hardware and software designed for engineering telemetry analysis, both real-time and non-real-time. The flexibility of the SFOC System has allowed the spacecraft team to integrate their own tools with SFOC tools to perform the tasks required to operate a spacecraft mission. This paper describes how the Magellan Spacecraft Team is utilizing the SFOC System in conjunction with their own software tools to perform the required tasks of spacecraft event monitoring as well as engineering data analysis and trending.

  1. Introducing capillary electrophoresis with laser-induced fluorescence (CE-LIF) as a potential analysis and quantification tool for galactooligosaccharides extracted from complex food matrices.

    PubMed

    Albrecht, Simone; Schols, Henk A; Klarenbeek, Bert; Voragen, Alphons G J; Gruppen, Harry

    2010-03-10

    The analysis and quantification of (galacto)oligosaccharides from food matrices demands both a reproducible extraction method as well as a sensitive and accurate analytical method. Three typical matrices, namely, infant formula, fruit juice, and a maltodextrin-rich preparation, to which a commercial galactooligosaccharide mixture was added in a product concentration range from 1.25 to 30%, served as model substrates. Solid-phase extraction on graphitized carbon material upon enzymatic amyloglucosidase pretreatment enabled a good recovery and a selective purification of the different galactooligosaccharide structures from the exceeding amounts of particularly lactose and maltodextrins. With the implementation of capillary electrophoresis in combination with laser-induced fluorescence (CE-LIF) detection, a new possibility facilitating a sensitive qualitative and quantitative determination of the galactooligosaccharide contents in the different food matrices is outlined. Simultaneous monitoring and quantifying prebiotic oligosaccharides embedded in food matrices presents a promising and important step toward an efficient monitoring of individual oligosaccharides and is of interest for research areas dealing with small quantities of oligosaccharides embedded in complex matrices, e.g., body liquids.

  2. Monitoring physical and chemical parameters of Delaware Bay waters with an ERTS-1 data collection platform

    NASA Technical Reports Server (NTRS)

    Klemas, V. (Principal Investigator); Wethe, C.

    1975-01-01

    The author has identified the following significant results. Results of the analysis of data collected during the summer of 1974 demonstrate that the ERTS Data Collection Platform (DCP) is quite responsive to changing water parameters and that this information can be successfully transmitted under all weather conditions. The monitoring of on-site probe outputs reveals a rapid response to changing water temperature, salinity, and turbidity conditions on incoming tides as the tidal salt wedge passes the probe location. The changes in water properties were corroborated by simultaneously sampling the water for subsequent laboratory analysis. Fluctuations observed in the values of salinity, conductivity, temperature and water depth over short time intervals were extremely small. Due to the nature of the probe, 10% to 20% fluctuations were observed in the turbidity values. The use of the average of the values observed during an overpass provided acceptable results. Good quality data was obtained from the satellite on each overpass regardless of weather conditions. Continued use of the DCP will help provide an indication of the accuracy of the probes and transmission system during long term use.

  3. Beam position monitor engineering

    NASA Astrophysics Data System (ADS)

    Smith, Stephen R.

    1997-01-01

    The design of beam position monitors often involves challenging system design choices. Position transducers must be robust, accurate, and generate adequate position signal without unduly disturbing the beam. Electronics must be reliable and affordable, usually while meeting tough requirements on precision, accuracy, and dynamic range. These requirements may be difficult to achieve simultaneously, leading the designer into interesting opportunities for optimization or compromise. Some useful techniques and tools are shown. Both finite element analysis and analytic techniques will be used to investigate quasi-static aspects of electromagnetic fields such as the impedance of and the coupling of beam to striplines or buttons. Finite-element tools will be used to understand dynamic aspects of the electromagnetic fields of beams, such as wake fields and transmission-line and cavity effects in vacuum-to-air feedthroughs. Mathematical modeling of electrical signals through a processing chain will be demonstrated, in particular to illuminate areas where neither a pure time-domain nor a pure frequency-domain analysis is obviously advantageous. Emphasis will be on calculational techniques, in particular on using both time domain and frequency domain approaches to the applicable parts of interesting problems.

  4. Evaluation of portable air samplers for monitoring airborne culturable bacteria

    NASA Technical Reports Server (NTRS)

    Mehta, S. K.; Bell-Robinson, D. M.; Groves, T. O.; Stetzenbach, L. D.; Pierson, D. L.

    2000-01-01

    Airborne culturable bacteria were monitored at five locations (three in an office/laboratory building and two in a private residence) in a series of experiments designed to compare the efficiency of four air samplers: the Andersen two-stage, Burkard portable, RCS Plus, and SAS Super 90 samplers. A total of 280 samples was collected. The four samplers were operated simultaneously, each sampling 100 L of air with collection on trypticase soy agar. The data were corrected by applying positive hole conversion factors for the Burkard portable, Andersen two-stage, and SAS Super 90 air samplers, and were expressed as log10 values prior to statistical analysis by analysis of variance. The Burkard portable air sampler retrieved the highest number of airborne culturable bacteria at four of the five sampling sites, followed by the SAS Super 90 and the Andersen two-stage impactor. The number of bacteria retrieved by the RCS Plus was significantly less than those retrieved by the other samplers. Among the predominant bacterial genera retrieved by all samplers were Staphylococcus, Bacillus, Corynebacterium, Micrococcus, and Streptococcus.

  5. Modified and improved sleep monitoring display console

    NASA Technical Reports Server (NTRS)

    Frost, J. D., Jr.

    1972-01-01

    An outline is given of a sleep monitoring display console capable of simultaneously displaying: (1) the visible current sleep stage of each subject, (2) a cumulative, numerical display (in hours and minutes) of the total amount of time the subject spends in each stage, and (3) a stepwise, graphic recording of subject's sleep stage versus time.

  6. Parenting by Cell Phone: Parental Monitoring of Adolescents and Family Relations

    ERIC Educational Resources Information Center

    Weisskirch, Robert S.

    2009-01-01

    Cellular phones provide a means for parents to monitor and request information about whereabouts, associates, and current activities from adolescents. Simultaneously, adolescents can communicate with parents to inform them of activities and to solicit support or they can also choose to nondisclose. The frequency, duration, and nature of calls may…

  7. A novel dual luciferase assay for the simultaneous monitoring of HIV infection and cell viability.

    PubMed

    Mitsuki, Yu-Ya; Yamamoto, Takuya; Mizukoshi, Fuminori; Momota, Masatoshi; Terahara, Kazutaka; Yoshimura, Kazuhisa; Harada, Shigeyoshi; Tsunetsugu-Yokota, Yasuko

    2016-05-01

    Human immunodeficiency virus type 1 (HIV-1) reporter cell lines are critical tools for drug development. However, one disadvantage of HIV-1 reporter cell lines is that reductions in reporter gene activity need to be normalized to cytotoxicity, i.e., live cell numbers. Here, we developed a dual luciferase assay based on a R. reniformis luciferase (hRLuc)-expressing R5-type HIV-1 (NLAD8-hRLuc) and a CEM cell line expressing CCR5 and firefly luciferase (R5CEM-FiLuc). The NLAD8-hRLuc reporter virus was replication competent in peripheral blood mononuclear cells. The level of hRLuc was correlated with p24 antigen levels (p<0.001, R=0.862). The target cell line, R5CEM-FiLuc, stably expressed the firefly luciferase (FiLuc) reporter gene and allowed the simultaneous monitoring of compound cytotoxicity. The dual reporter assay combining a NLAD8-hRLuc virus with R5CEM-FiLuc cells permitted the accurate determination of drug susceptibility for entry, reverse transcriptase, integrase, and protease inhibitors at different multiplicities of infection. This dual reporter assay provides a rapid and direct method for the simultaneous monitoring of HIV infection and cell viability. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. First demonstration of simultaneous measurement of beam current, beam position, and beam tilt on induction linac using combined B-dot monitor

    NASA Astrophysics Data System (ADS)

    He, Xiaozhong; Pang, Jian; Chen, Nan; Li, Qin; Dai, Wenhua; Ma, Chaofan; Zhao, Liangchao; Gao, Feng; Dai, Zhiyong

    2017-06-01

    The authors previously reported that the axial B-dots can be used to directly measure the beam tilt and demonstrated that the axial B-dots are applicable to a coaxial calibration stand. In this study, a combined B-dot monitor composed of four axial B-dot loops and four azimuthal ones is tested for the simultaneous measurement of the time-varying beam current, beam offset, and beam tilt at the output of the injector of the DRAGON-I induction linac. In the experiments, the beam offset and beam tilt at the position of the monitor are proportionally adjusted using a pair of steering coils. Eight waveforms acquired from the B-dot monitor are analyzed to reconstruct the time-varying beam current, beam offset, and beam tilt. The original signals of both the azimuthal B-dot and the axial B-dot ports change significantly with respect to the current applied to the steering coils. The measured beam tilt is linearly dependent on the current applied to the steering coils and agrees well with the measured beam offset.

  9. Geodetic monitoring of subrosion-induced subsidence processes in urban areas

    NASA Astrophysics Data System (ADS)

    Kersten, Tobias; Kobe, Martin; Gabriel, Gerald; Timmen, Ludger; Schön, Steffen; Vogel, Detlef

    2017-03-01

    The research project SIMULTAN applies an advanced combination of geophysical, geodetic, and modelling techniques to gain a better understanding of the evolution and characteristics of sinkholes. Sinkholes are inherently related to surface deformation and, thus, of increasing societal relevance, especially in dense populated urban areas. One work package of SIMULTAN investigates an integrated approach to monitor sinkhole-related mass translations and surface deformations induced by salt dissolution. Datasets from identical and adjacent points are used for a consistent combination of geodetic and geophysical techniques. Monitoring networks are established in Hamburg and Bad Frankenhausen (Thuringia). Levelling surveys indicate subsidence rates of about 4-5 mm per year in the main subsidence areas of Bad Frankenhausen with a local maximum of 10 mm per year around the leaning church tower. Here, the concept of combining geodetic and gravimetric techniques to monitor and characterise geological processes on and below the Earth's surface is exemplary discussed for the focus area Bad Frankenhausen. For the different methods (levelling, GNSS, relative/absolute gravimetry) stable network results at identical points are obtained by the first campaigns, i.e., the results are generally in agreement.

  10. The GBT-SCA, a radiation tolerant ASIC for detector control and monitoring applications in HEP experiments

    NASA Astrophysics Data System (ADS)

    Caratelli, A.; Bonacini, S.; Kloukinas, K.; Marchioro, A.; Moreira, P.; De Oliveira, R.; Paillard, C.

    2015-03-01

    The future upgrades of the LHC experiments will increase the beam luminosity leading to a corresponding growth of the amounts of data to be treated by the data acquisition systems. To address these needs, the GBT (Giga-Bit Transceiver optical link [1,2]) architecture was developed to provide the simultaneous transfer of readout data, timing and trigger signals as well as slow control and monitoring data. The GBT-SCA ASIC, part of the GBT chip-set, has the purpose to distribute control and monitoring signals to the on-detector front-end electronics and perform monitoring operations of detector environmental parameters. In order to meet the requirements of different front-end ASICs used in the experiments, it provides various user-configurable interfaces capable to perform simultaneous operations. It is designed employing radiation tolerant design techniques to ensure robustness against SEUs and TID radiation effects and is implemented in a commercial 130 nm CMOS technology. This work presents the GBT-SCA architecture, the ASIC interfaces, the data transfer protocol, and its integration with the GBT optical link.

  11. Online monitoring of chemical reactions by polarization-induced electrospray ionization.

    PubMed

    Meher, Anil Kumar; Chen, Yu-Chie

    2016-09-21

    Polarization-induced electrospray ionization (PI-ESI) is a simple technique for instant generation of gas-phase ions directly from a microliter-sized droplet for mass spectrometric analysis. A sample droplet was placed over a dielectric substrate and in proximity (2-3 mm) to the inlet of a mass spectrometer. Owing to the polarization effect induced by the high electric field provided by the mass spectrometer, the droplet was polarized and the electrospray was generated from the apex of the droplet. The polarization-induced electrospray could last for tens of seconds, which was sufficiently long to monitor fast reactions occurring within few seconds. Thus, we demonstrated the feasibility of using the droplet-based PI-ESI MS for the online monitoring of fast reactions by simply mixing two droplets (5-10 μL) containing reactants on a dielectric substrate placed in front of a mass spectrometer applied with a high voltage (-4500 V). Schiff base reactions and oxidation reactions that can generate intermediates/products within a few seconds were selected as the model reactions. The ionic reaction species generated from intermediates and products can be simultaneously monitored by PI-ESI MS in real time. We also used this approach to selectively detect acetone from a urine sample, in which acetone was derivatized in situ. In addition, the possibility of using this approach for quantitative analysis of acetone from urine samples was examined. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. [Between caring and monitoring: ambiguities and contradictions in the discourse of a female penitentiary officer].

    PubMed

    Barcinski, Mariana; Altenbernd, Bibiana; Campani, Cristiane

    2014-07-01

    The scope of this paper was to establish how the discourse of a female penitentiary officer working in a prison for women reflects, in different ways, the inherent contradiction of prisons, namely their double mission of punishing and resocializing criminals. The data collected in a female prison in Rio Grande do Sul were evaluated using Critical Discourse Analysis, which seeks to understand how discursive productions reflect social power relations. The analyses show that this officer's practice is based simultaneously on punitive and resocializing ideologies, expressed in contradictory feelings of anger and affection towards incarcerated women. Results point to the centrality of gender in the relationship established between officers and interns. Thus, the fact of being a female officer caring and monitoring other women makes this daily relationship even more complex. This complexity extrapolates the limits imposed by prisons.

  13. CMS Centres Worldwide - a New Collaborative Infrastructure

    NASA Astrophysics Data System (ADS)

    Taylor, Lucas

    2011-12-01

    The CMS Experiment at the LHC has established a network of more than fifty inter-connected "CMS Centres" at CERN and in institutes in the Americas, Asia, Australasia, and Europe. These facilities are used by people doing CMS detector and computing grid operations, remote shifts, data quality monitoring and analysis, as well as education and outreach. We present the computing, software, and collaborative tools and videoconferencing systems. These include permanently running "telepresence" video links (hardware-based H.323, EVO and Vidyo), Webcasts, and generic Web tools such as CMS-TV for broadcasting live monitoring and outreach information. Being Web-based and experiment-independent, these systems could easily be extended to other organizations. We describe the experiences of using CMS Centres Worldwide in the CMS data-taking operations as well as for major media events with several hundred TV channels, radio stations, and many more press journalists simultaneously around the world.

  14. Microbial community structure in a shallow hydrocarbon-contaminated aquifer associated with high electrical conductivity

    NASA Astrophysics Data System (ADS)

    Duris, J. W.; Rossbach, S.; Atekwana, E. A.; Werkema, D., Jr.

    2003-04-01

    Little is known about the complex interactions between microbial communities and electrical properties in contaminated aquifers. In order to investigate possible connections between these parameters a study was undertaken to investigate the hypothesis that the degradation of hydrocarbons by resident microbial communities causes a local increase in organic acid concentrations, which in turn cause an increase in native mineral weathering and a concurrent increase in the bulk electrical conductivity of soil. Microbial community structure was analyzed using a 96-well most probable number (MPN) method and rDNA intergenic spacer region analysis (RISA). Microbial community structure was found to change in the presence of hydrocarbon contaminants and these changes were consistently observed in regions of high electrical conductivity. We infer from this relationship that geophysical methods for monitoring the subsurface are a promising new technology for monitoring changes in microbial community structure and simultaneous changes in geochemistry that are associated with hydrocarbon degradation.

  15. Nonintrusive biosignal measurement system in a vehicle.

    PubMed

    Lee, Haet Bit; Choi, Jong Min; Kim, Jung Soo; Kim, Yun Seong; Baek, Hyun Jae; Ryu, Myung Suk; Sohn, Ryang Hee; Park, Kwang Suk

    2007-01-01

    Measurement of driver's state is important in both daily healthcare and prevention of car accidents. Existing measurement methods, however, are too complex and uncomfortable to measure for everyday. A nonintrusive biosignal monitoring system is demanded for increasing the accessibility. In this paper, we proposed a nonintrusive measurement system integrated in a vehicle for recording electrocardiographic (ECG) signals and tested the performance of the system. The system consists of dry electrodes attached to the steering wheel and a wireless communication module using a Bluetooth device. ECG signals measured by our system were compared with those by a conventional system employing wet electrodes during real city road driving. Various parameters used for HRV analysis in time and frequency domain showed no significant differences between the two simultaneously measured ECG signals. The result implies the possibility that developed system could have a potential to monitor health information in a vehicle instead of commercial equipments.

  16. Zooming In on Plant Hormone Analysis: Tissue- and Cell-Specific Approaches.

    PubMed

    Novák, Ondřej; Napier, Richard; Ljung, Karin

    2017-04-28

    Plant hormones are a group of naturally occurring, low-abundance organic compounds that influence physiological processes in plants. Our knowledge of the distribution profiles of phytohormones in plant organs, tissues, and cells is still incomplete, but advances in mass spectrometry have enabled significant progress in tissue- and cell-type-specific analyses of phytohormones over the last decade. Mass spectrometry is able to simultaneously identify and quantify hormones and their related substances. Biosensors, on the other hand, offer continuous monitoring; can visualize local distributions and real-time quantification; and, in the case of genetically encoded biosensors, are noninvasive. Thus, biosensors offer additional, complementary technologies for determining temporal and spatial changes in phytohormone concentrations. In this review, we focus on recent advances in mass spectrometry-based quantification, describe monitoring systems based on biosensors, and discuss validations of the various methods before looking ahead at future developments for both approaches.

  17. Simultaneous high-performance liquid chromatographic analysis of pregabalin, gabapentin and vigabatrin in human serum by precolumn derivatization with o-phtaldialdehyde and fluorescence detection.

    PubMed

    Vermeij, T A C; Edelbroek, P M

    2004-10-25

    A rapid, simple and robust method is presented for the simultaneous determination of the gamma-amino-n-butyric acid (GABA) derivatives pregabalin (PGB), gabapentin (GBP) and vigabatrin (VGB) in human serum by high-performance liquid chromatography (HPLC). Serum is deproteinized with trichloroacetic acid and aliquots of the supernatant are precolumn derivatized with o-phtaldialdehyde (OPA) and 3-mercaptopropionic acid. Separation is achieved on a Alltima 3C18 column using isocratic elution; the drugs are monitored using fluorescence detection. Norvaline is used as an internal standard. Within-day precision (COV; n = 10) is 1.2% for PGB (serum concentration 10.0 mg/l), 1.1% for GBP (serum concentration 15.8 mg/l) and 0.3% for VGB (serum concentration 15.5 mg/l). The method is linear up to at least 63 mg/l for PGB, 40 mg/l for GBP and 62 mg/l for VGB. Lower limits of quantitation (LOQ) are 0.13 mg/l for PGB, 0.53 mg/l for GBP and 0.06 mg/l for VGB. No interferences were found from commonly coadministered antiepileptic drugs (AEDs) and from endogenous amino acids. Experimental design in combination with statistical evaluation (ANOVA) was used to study the robustness of chromatography and sample preparation. The method is very suitable for routine therapeutic drug monitoring and for pharmacokinetic studies.

  18. Changes in High Elevation Lake Ecosystems of the Sierra Nevada during the 20th Century: Combining Long-term Monitoring with Paleolimnology

    NASA Astrophysics Data System (ADS)

    Sickman, J. O.; Heard, A. M.; Rose, N. L.; Bennett, D. M.; Lucero, D. M.; Melack, J. M.; Curtis, J. H.

    2014-12-01

    High mountain lakes of the Sierra Nevada are excellent indicators of anthropogenic global change due to their limited capacity to buffer acid deposition, their sensitivity to changes in snowpack dynamics and their oligotrophic nutrient status. In this presentation, we examine long-term records of hydrochemistry and biological monitoring at the Emerald Lake watershed to assess whether high elevation lakes of the Sierra Nevada are changing in response to climate change or changes in atmospheric deposition of nutrients and acid. To provide a broader context for these changes, we augment these long-term records with results from paleolimnological analysis that examines changes in nutrient status and acid buffering capacity of Sierra Nevada lakes over the past two millennia. Our research suggests that, although atmospheric deposition is the dominant driver of twentieth century ANC trends, aquatic communities in the Sierra Nevada are responding to combined effects from acidification, climate change, and eutrophication. Early in the twentieth century the primary stressor effecting Sierra Nevada lakes was acid deposition driven by SO2 emissions. As the century and industrialization progressed, NOx levels increased adding a eutrophication stressor while simultaneously contributing to acidification. Effects were further complicated by a warming climate in the late twentieth century, as warmer temperatures may have contributed to the recovery of ANC in lakes via increased weathering rates, while simultaneously enhancing eutrophication effects.

  19. The Malaysian Robotic Solar Observatory (P29)

    NASA Astrophysics Data System (ADS)

    Othman, M.; Asillam, M. F.; Ismail, M. K. H.

    2006-11-01

    Robotic observatory with small telescopes can make significant contributions to astronomy observation. They provide an encouraging environment for astronomers to focus on data analysis and research while at the same time reducing time and cost for observation. The observatory will house the primary 50cm robotic telescope in the main dome which will be used for photometry, spectroscopy and astrometry observation activities. The secondary telescope is a robotic multi-apochromatic refractor (maximum diameter: 15 cm) which will be housed in the smaller dome. This telescope set will be used for solar observation mainly in three different wavelengths simultaneously: the Continuum, H-Alpha and Calcium K-line. The observatory is also equipped with an automated weather station, cloud & rain sensor and all-sky camera to monitor the climatic condition, sense the clouds (before raining) as well as to view real time sky view above the observatory. In conjunction with the Langkawi All-Sky Camera, the observatory website will also display images from the Malaysia - Antarctica All-Sky Camera used to monitor the sky at Scott Base Antarctica. Both all-sky images can be displayed simultaneously to show the difference between the equatorial and Antarctica skies. This paper will describe the Malaysian Robotic Observatory including the systems available and method of access by other astronomers. We will also suggest possible collaboration with other observatories in this region.

  20. High-throughput and simultaneous analysis of eight central-acting muscle relaxants in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry in the positive and negative ionization modes.

    PubMed

    Ogawa, Tadashi; Hattori, Hideki; Kaneko, Rina; Ito, Kenjiro; Iwai, Masae; Mizutani, Yoko; Arinobu, Tetsuya; Ishii, Akira; Seno, Hiroshi

    2011-06-01

    In this report, a high-throughput and sensitive method for analysis of eight central-acting muscle relaxants in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) in the positive and negative ionization modes using tolbutamide as internal standard is presented. After pretreatment of a plasma sample by solid-phase extraction with an Oasis HLB cartridge, muscle relaxants were analyzed by UPLC with Acquity UPLC BEH C(18) column and Acquity TQD tandem quadrupole mass spectrometer equipped with an electrospray ionization interface. The calibration curves for muscle relaxants spiked into human plasma equally showed good linearities in the nanogram per milliliter order range. The detection limits (signal-to-noise ratio = 3) was as low as 0.1-2 ng/mL. The method gave satisfactory recovery rates, accuracy, and precision for quality control samples spiked with muscle relaxants. To further validate the present method, 250 mg of chlorphenesin carbamate was orally administered to a healthy male volunteer, and the concentrations of chlorphenesin carbamate in plasma were measured 0.5, 1, 2, 4, 6, and 8 h after dosing; their concentrations in human plasma were between 0.62 and 2.44 μg/mL. To our knowledge, this is the first report describing simultaneous analysis of over more than two central-acting muscle relaxants by liquid chromatography-tandem mass spectrometry. This has been realized by the capability of our instrument for simultaneous multiple reaction monitoring of the target compounds in both positive and negative ionization modes. Therefore, the present method seems very useful in forensic and clinical toxicology and pharmacokinetic studies.

  1. Data Pre-Processing for Label-Free Multiple Reaction Monitoring (MRM) Experiments

    PubMed Central

    Chung, Lisa M.; Colangelo, Christopher M.; Zhao, Hongyu

    2014-01-01

    Multiple Reaction Monitoring (MRM) conducted on a triple quadrupole mass spectrometer allows researchers to quantify the expression levels of a set of target proteins. Each protein is often characterized by several unique peptides that can be detected by monitoring predetermined fragment ions, called transitions, for each peptide. Concatenating large numbers of MRM transitions into a single assay enables simultaneous quantification of hundreds of peptides and proteins. In recognition of the important role that MRM can play in hypothesis-driven research and its increasing impact on clinical proteomics, targeted proteomics such as MRM was recently selected as the Nature Method of the Year. However, there are many challenges in MRM applications, especially data pre‑processing where many steps still rely on manual inspection of each observation in practice. In this paper, we discuss an analysis pipeline to automate MRM data pre‑processing. This pipeline includes data quality assessment across replicated samples, outlier detection, identification of inaccurate transitions, and data normalization. We demonstrate the utility of our pipeline through its applications to several real MRM data sets. PMID:24905083

  2. Data Pre-Processing for Label-Free Multiple Reaction Monitoring (MRM) Experiments.

    PubMed

    Chung, Lisa M; Colangelo, Christopher M; Zhao, Hongyu

    2014-06-05

    Multiple Reaction Monitoring (MRM) conducted on a triple quadrupole mass spectrometer allows researchers to quantify the expression levels of a set of target proteins. Each protein is often characterized by several unique peptides that can be detected by monitoring predetermined fragment ions, called transitions, for each peptide. Concatenating large numbers of MRM transitions into a single assay enables simultaneous quantification of hundreds of peptides and proteins. In recognition of the important role that MRM can play in hypothesis-driven research and its increasing impact on clinical proteomics, targeted proteomics such as MRM was recently selected as the Nature Method of the Year. However, there are many challenges in MRM applications, especially data pre‑processing where many steps still rely on manual inspection of each observation in practice. In this paper, we discuss an analysis pipeline to automate MRM data pre‑processing. This pipeline includes data quality assessment across replicated samples, outlier detection, identification of inaccurate transitions, and data normalization. We demonstrate the utility of our pipeline through its applications to several real MRM data sets.

  3. UPLC-MS/MS method for therapeutic drug monitoring of 10 antibiotics used in intensive care units.

    PubMed

    El-Najjar, Nahed; Hösl, Julian; Holzmann, Thomas; Jantsch, Jonathan; Gessner, André

    2018-03-01

    A large variation in the levels of different ß-lactams and other antibiotics used in critically ill patients has been documented. The aim of this study is to establish and validate a fast, ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for the simultaneous analysis of ten antibiotics (Meropenem, Cefepime, Ceftazidime, Piperacillin, Benzylpenicillin, Ampicillin, Flucloxacillin, Linezolid, and Sulfamethoxazole/Trimethoprim) in human plasma according to European Medicines Agency (EMA) guidelines. Protein precipitation with ice-cold methanol containing 9 isotopically labeled internal standards was used for sample clean up. Antibiotics were detected, following a 4-minute gradient separation, in multiple reactions monitoring (MRM) using API 4000 instrument equipped with electrospray source operating in positive ion mode. The lower limit of quantification was 0.1 mg/L for Meropenem, Ceftazidime, Piperacillin, Ampicillin, Flucloxacillin, and Sulfamethoxazole; 0.05 mg/L for Cefepime, Benzylpenicillin, and Trimethoprim; and 0.02 mg/L for Linezolid. The method proved to be precise and accurate and applicable for therapeutic drug monitoring and other pharmacokinetic studies. Copyright © 2017 John Wiley & Sons, Ltd.

  4. Methodological Approaches for Monitoring Opportunistic Pathogens in Premise Plumbing: A Review

    PubMed Central

    Wang, Hong; Bedard, Emilie; Prevost, Michele; Camper, Anne K.; Hill, Vincent R.; Pruden, Amy

    2017-01-01

    Opportunistic pathogens inhabiting premise (i.e., building) plumbing (OPPPs, e.g., L. pneumophila, M. avium complex, P. aeruginosa, Acanthamoeba, and N. fowleri) are a significant and growing source of disease. Because OPPPs establish and grow as part of the native drinking water microbiota, they do not correspond to fecal indicators, presenting a significant challenge to common and effective monitoring strategies. Further, different OPPPs present distinct requirements for sampling, preservation, and analysis, creating a significant impediment to their parallel detection. The aim of this critical review is to synthesize the state of the science of monitoring OPPPs and to identify a path forward for their simultaneous detection and quantification in a manner commensurate with the need for reliable data to inform risk assessment and mitigation. Water and biofilm sampling procedures, as well as factors influencing sample representativeness and detection sensitivity, are critically evaluated with respect to the five representative bacterial and amoebal OPPPs noted above. Available culturing and molecular approaches are discussed in terms of their advantages, limitations, and applicability. Knowledge gaps and research needs are identified. PMID:28390237

  5. Simultaneous determination of 5'-monophosphate nucleotides in infant formulas by HPLC-MS.

    PubMed

    Ren, Yiping; Zhang, Jingshun; Song, Xiaodan; Chen, Xiaochun; Li, Duo

    2011-04-01

    A method was developed for simultaneous determination of 5'-monophosphate nucleotides, adenosine 5'-monophosphate, cytidine 5'-monophosphate, guanosine 5'-monophosphate, inosine 5'-monophosphate, and uridine 5'-monophosphate in infant formulas by high-performance liquid chromatography-mass spectrometry equipped with electrospray ionization source. The complete chromatographic separation of five nucleotides was achieved through a Symmetry C(18) column, after a binary gradient elution with water containing 0.1% formic acid and acetonitrile as mobile phase. The multi-reaction monitoring mode was applied for tandem mass spectrometry analysis. The established method was further validated by determining the linearity (R(2) > 0.999), recovery (92.0-105.0%), and precision (relative standard deviation ≤6.97%). To verify the applicability of the method, thirty commercially available infant formulas were randomly purchased from the supermarkets in Hangzhou, China, and then analyzed. The results showed that the developed method is validated, sensitive, and reliable for quantitation of nucleotides in infant formulas.

  6. Simultaneous analysis of D-alanine, D-aspartic acid, and D-serine using chiral high-performance liquid chromatography-tandem mass spectrometry and its application to the rat plasma and tissues.

    PubMed

    Karakawa, Sachise; Shimbo, Kazutaka; Yamada, Naoyuki; Mizukoshi, Toshimi; Miyano, Hiroshi; Mita, Masashi; Lindner, Wolfgang; Hamase, Kenji

    2015-11-10

    A highly sensitive and selective chiral LC-MS/MS method for D-alanine, D-aspartic acid and D-serine has been developed using the precolumn derivatization reagents, 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AccQ-Tag) or p-N,N,N-trimethylammonioanilyl N'-hydroxysuccinimidyl carbamate iodide (TAHS). The thus N-tagged enantiomers of the derivatized amino acids were nicely separated within 20min using the cinchona alkaloid-based zwittterionic ion-exchange type enantioselective column, Chiralpak ZWIX(+). The selected reaction monitoring was applied for detecting the target d-amino acids in biological matrices. By using the present chiral LC-MS/MS method, the three d-amino acids and their l-forms could be simultaneously determined in the range of 0.1-500nmol/mL. Finally, the technique was successfully applied to rat plasma and tissue samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Fetal bovine serum simultaneously stimulates apoptosis and DNA synthesis in premeiotic stages of spermatogenesis in spiny dogfish (Squalus acanthias) in vitro: modulation by androgen and spermatogenic activity status.

    PubMed

    McClusky, Leon Mendel

    2008-05-01

    Using the simple cystic spermatogenesis in the shark testis as a model, we previously reported the relative resistance of immature spermatogonia (stem cell and early-stage spermatogonia) to apoptosis in the normal testis and after spermatoxicant exposure in vivo. Apoptosis was monitored by fluorescence image analysis of living cysts, using the validated acridine orange (AO) vital staining technique. Findings show that FBS simultaneously stimulates both apoptosis and [(3)H]thymidine incorporation in immature spermatogonial clones in a concentration-dependent manner in vitro. Furthermore, androgen inhibits apoptosis and increases cyst viability, more so with 10% FBS than with 1% FBS. All the effects were as a function of spermatogenic activity status but were distinct in early-stage spermatogonial cysts isolated from testes awakening from the previous winter spermatogenic arrest period. Results are discussed in the context of the alternating germ-Sertoli cell population kinetics of early-stage spermatogonial cysts in Squalus acanthias's protracted testicular cycle.

  8. A data fusion-based drought index

    NASA Astrophysics Data System (ADS)

    Azmi, Mohammad; Rüdiger, Christoph; Walker, Jeffrey P.

    2016-03-01

    Drought and water stress monitoring plays an important role in the management of water resources, especially during periods of extreme climate conditions. Here, a data fusion-based drought index (DFDI) has been developed and analyzed for three different locations of varying land use and climate regimes in Australia. The proposed index comprehensively considers all types of drought through a selection of indices and proxies associated with each drought type. In deriving the proposed index, weekly data from three different data sources (OzFlux Network, Asia-Pacific Water Monitor, and MODIS-Terra satellite) were employed to first derive commonly used individual standardized drought indices (SDIs), which were then grouped using an advanced clustering method. Next, three different multivariate methods (principal component analysis, factor analysis, and independent component analysis) were utilized to aggregate the SDIs located within each group. For the two clusters in which the grouped SDIs best reflected the water availability and vegetation conditions, the variables were aggregated based on an averaging between the standardized first principal components of the different multivariate methods. Then, considering those two aggregated indices as well as the classifications of months (dry/wet months and active/non-active months), the proposed DFDI was developed. Finally, the symbolic regression method was used to derive mathematical equations for the proposed DFDI. The results presented here show that the proposed index has revealed new aspects in water stress monitoring which previous indices were not able to, by simultaneously considering both hydrometeorological and ecological concepts to define the real water stress of the study areas.

  9. Cohort monitoring of persons with hypertension: an illustrated example from a primary healthcare clinic for Palestine refugees in Jordan.

    PubMed

    Khader, Ali; Farajallah, Loai; Shahin, Yousef; Hababeh, Majed; Abu-Zayed, Ishtaiwi; Kochi, Arata; Harries, Anthony D; Zachariah, Rony; Kapur, Anil; Venter, Wendy; Seita, Akihiro

    2012-09-01

    Recording and reporting systems borrowed from the DOTS framework for tuberculosis control can be used to record, monitor and report on chronic disease. In a primary healthcare clinic run by UNRWA in Amman, Jordan, serving Palestine refugees with hypertension, we set out to illustrate the method of cohort reporting for persons with hypertension by presenting on quarterly and cumulative case finding, cumulative and 12-month analysis of cohort outcomes and to assess how these data may inform and improve the quality of hypertension care services. This was a descriptive study using routine programme data collected through E-Health. There were 97 newly registered patients with hypertension in quarter 1, 2012, and a total of 4130 patients with hypertension ever registered since E-Health started in October 2009. By 31 March 2012, 3119 (76%) of 4130 patients were retained in care, 878 (21%) had failed to present to a healthcare worker in the last 3 months and the remainder had died, transferred out or were lost to follow-up. Cumulative and 12-month cohort outcome analysis indicated deficiencies in several components of clinical performance related to blood pressure measurements and fasting blood glucose tests to screen simultaneously for diabetes. Between 8% and 15% of patients with HT had serious complications such as cardiovascular disease and stroke. Cohort analysis is a valuable tool for the monitoring and management of non-communicable chronic diseases such as HT. © 2012 Blackwell Publishing Ltd.

  10. MR thermometry analysis program for laser- or high-intensity focused ultrasound (HIFU)-induced heating at a clinical MR scanner

    NASA Astrophysics Data System (ADS)

    Kim, Eun Ju; Jeong, Kiyoung; Oh, Seung Jae; Kim, Daehong; Park, Eun Hae; Lee, Young Han; Suh, Jin-Suck

    2014-12-01

    Magnetic resonance (MR) thermometry is a noninvasive method for monitoring local temperature change during thermal therapy. In this study, a MR temperature analysis program was established for a laser with gold nanorods (GNRs) and high-intensity focused ultrasound (HIFU)-induced heating MR thermometry. The MR temperature map was reconstructed using the water proton resonance frequency (PRF) method. The temperature-sensitive phase difference was acquired by using complex number subtraction instead of direct phase subtraction in order to avoid another phase unwrapping process. A temperature map-analyzing program was developed and implemented in IDL (Interactive Data Language) for effective temperature monitoring. This one program was applied to two different heating devices at a clinical MR scanner. All images were acquired with the fast spoiled gradient echo (fSPGR) pulse sequence on a 3.0 T GE Discovery MR750 scanner with an 8-channel knee array coil or with a home-built small surface coil. The analyzed temperature values were confirmed by using values simultaneously measured with an optical temperature probe (R2 = 0.996). The temperature change in small samples induced by a laser or by HIFU was analyzed by using a raw data, that consisted of complex numbers. This study shows that our MR thermometry analysis program can be used for thermal therapy study with a laser or HIFU at a clinical MR scanner. It can also be applied to temperature monitoring for any other thermal therapy based on the PRF method.

  11. Simultaneous determination of anemoside B4, phellodendrine, berberine, palmatine, obakunone, esculin, esculetin in rat plasma by UPLC-ESI-MS/MS and its application to a comparative pharmacokinetic study in normal and ulcerative colitis rats.

    PubMed

    Yang, Lianrong; Meng, Xin; Yu, Xiaojin; Kuang, Haixue

    2017-02-05

    A sensitive and rapid ultra-performance liquid chromatography-electrospray ionization-mass spectrometry (UPLC-ESI-MS/MS) method was developed for the simultaneous analysis of anemoside B4, phellodendrine, berberine, palmatine, obakunone, esculin, esculetin, toosendanin (IS 1 of anemoside B4), tetrahydropalmatine (IS 2 of phellodendrine, berberine, palmatine and obakunone) and scopoletin (IS 3 of esculin and esculetin) and to compare the pharmacokinetics of these active ingredients in normal and ulcerative colitis rats. After methanol deproteinization, solvents were evaporated at 40°C under a gentle stream of nitrogen. Chromatography was performed using a C18 column with a gradient elution of 0.1% aqueous formic acid and acetonitrile at 0.4ml/min. Detection and measurement were performed on a 4000 QTRAP UPLC-MS/MS system from AB Sciex in the multiple reaction monitoring (MRM) mode. Phellodendrine, berberine, palmatine, obakunone, esculin, esculetin, tetrahydropalmatine (IS 2 ) and scopoletin (IS 3 ) were monitored under positive ionization conditions. Anemoside B4, and toosendanin (IS 1 ) were monitored under negative ionization conditions. The optimized mass transition ion-pairs (m/z) were 1221.1/750.7 for anemoside B4, 343.2/193.2 for phellodendrine, 337.1/321.0 for berberine, 353.0/336.9 for palmatine, 455.1/161.1 for obakunone, 341.2/179.2 for esculin, 179.1/123.0 for esculetin, 573.4/531.4 for toosendanin (IS 1 ), 356.2/192.2 for tetrahydropalmatine (IS 2 ) and 193.0/133.1 for scopoletin (IS 3 ). Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Simultaneous in situ Optical Monitoring Techniques during Crystal Growth of ZnSe by Physical Vapor Transport

    NASA Technical Reports Server (NTRS)

    Su, C.- H.; Feth, S.; Lehoczky, S. L.

    1998-01-01

    ZnSe crystals grown in sealed ampoules by the physical vapor transport method were monitored in situ using three techniques, simultaneously. A Michelson interferometer was set-up to observe the growth rate and surface morphological evolution. An interference pattern (interferogram) is formed by the interaction between the reflection of a HeNe laser (632.8 nm wavelength) off the crystal-vapor interface and a reference beam from the same laser. Preliminary results indicate that the rate of growth/thermal-etching can be calculated using analog data acquisition and simple fringe counting techniques. Gross surface features may also be observed using a digital frame grabber and fringe analysis software. The second in situ technique uses optical absorption to determine the partial pressures of the vapor species. The Se2 and Zn vapor species present in the sealed ampoule absorb light at characteristic wavelengths. The optical absorption is determined by monitoring the light intensity difference between the sample and reference beams. The Se2 Partial pressure profile along the length of the ampoule was estimated from the vibronic absorption peaks at 340.5, 350.8, 361.3 and 379.2 nm using the Beer's law constants established in the calibration runs of pure Se. Finally, because the high temperature crystal growth furnace contains windows, in situ visual observation of the growing crystal is also possible. The use of these techniques not only permits in situ investigation of high temperature vapor growth of semiconductors, but also offers the potential for real time feed back on the growing crystal and allows the possibility of actively controlling the growth process.

  13. Radial to femoral arterial blood pressure differences in septic shock patients receiving high-dose norepinephrine therapy.

    PubMed

    Kim, Won Young; Jun, Jong Hun; Huh, Jin Won; Hong, Sang Bum; Lim, Chae-Man; Koh, Younsuck

    2013-12-01

    The accuracy of arterial blood pressure (ABP) monitoring is crucial in treating septic shock patients. Clinically significant differences in central to peripheral ABP could develop into sepsis during vasopressor therapy. The aim of this study was to investigate the difference between radial (peripheral) and femoral (central) ABP in septic shock patients receiving high-dose norepinephrine (NE) therapy. This prospective observational study comparing simultaneous intra-arterial measurements of radial and femoral ABP was performed at a university-affiliated, tertiary referral center between October 2008 and March 2009. Patients with septic shock who needed continuous blood pressure monitoring and high-dose NE therapy 0.1 µg/kg per minute or greater to maintain mean arterial pressure (MAP) of 65 mmHg or greater were included. Statistical analysis was conducted using the Bland-Altman method for comparison of repeated measures. In total, 250 sets of systolic, mean, and diastolic femoral and radial ABP were recorded at baseline and after NE titration. Arterial blood pressure readings from the radial artery were underestimated compared with those from the femoral artery. Overall bias (mean difference between simultaneous measurements) between radial and femoral MAP was +4.9 mmHg; however, during high-dose NE therapy, the bias increased to +6.2 mmHg (95% limits of agreement: -6.0 to +18.3 mmHg). Clinically significant radial-femoral MAP differences (MAP ≥5 mmHg) occurred in up to 62.2% of patients with high-dose NE therapy. Radial artery pressure frequently underestimates central pressure in septic shock patients receiving high-dose NE therapy. Femoral arterial pressure monitoring may be more appropriate when high-dose NE therapy is administered.

  14. From the speed of sound to the speed of light: Ultrasonic Cherenkov refractometry

    NASA Astrophysics Data System (ADS)

    Hallewell, G. D.

    2017-12-01

    Despite its success in the SLD CRID at the SLAC Linear Collider, ultrasonic measurement of Cherenkov radiator refractive index has been less fully exploited in more recent Cherenkov detectors employing gaseous radiators. This is surprising, since it is ideally suited to monitoring hydrostatic variations in refractive index as well as its evolution during the replacement of a light radiator passivation gas (e.g. N2, CO2) with a heavier fluorocarbon (e.g. C4F10[CF4]; mol. wt. 188[88]). The technique exploits the dependence of sound velocity on the molar concentrations of the two components at known temperature and pressure. The SLD barrel CRID used an 87%C5F12/13%N2 blend, mixed before injection into the radiator vessel: blend control based on ultrasonic mixture analysis maintained the β=1 Cherenkov ring angle to a long term variation better than ±0.3%, with refractivity monitored ultrasonically at multiple points within the radiator vessel. Recent advances using microcontroller-based electronics have led to ultrasonic instruments capable of simultaneously measuring gas flow and binary mixture composition in the fluorocarbon evaporative cooling systems of the ATLAS Inner Detector. Sound transit times are measured with multi-MHz transit time clocks in opposite directions in flowing gas for simultaneous measurement of flow rate and sound velocity. Gas composition is evaluated in real-time by comparison with a sound velocity/composition database. Such instruments could be incorporated into new and upgraded gas Cherenkov detectors for radiator gas mixture (and corresponding refractive index) measurement to a precision better than 10-3. They have other applications in binary gas analysis - including in Xenon-based anaesthesia. These possibilities are discussed.

  15. Near real-time estimation of the seismic source parameters in a compressed domain

    NASA Astrophysics Data System (ADS)

    Rodriguez, Ismael A. Vera

    Seismic events can be characterized by its origin time, location and moment tensor. Fast estimations of these source parameters are important in areas of geophysics like earthquake seismology, and the monitoring of seismic activity produced by volcanoes, mining operations and hydraulic injections in geothermal and oil and gas reservoirs. Most available monitoring systems estimate the source parameters in a sequential procedure: first determining origin time and location (e.g., epicentre, hypocentre or centroid of the stress glut density), and then using this information to initialize the evaluation of the moment tensor. A more efficient estimation of the source parameters requires a concurrent evaluation of the three variables. The main objective of the present thesis is to address the simultaneous estimation of origin time, location and moment tensor of seismic events. The proposed method displays the benefits of being: 1) automatic, 2) continuous and, depending on the scale of application, 3) of providing results in real-time or near real-time. The inversion algorithm is based on theoretical results from sparse representation theory and compressive sensing. The feasibility of implementation is determined through the analysis of synthetic and real data examples. The numerical experiments focus on the microseismic monitoring of hydraulic fractures in oil and gas wells, however, an example using real earthquake data is also presented for validation. The thesis is complemented with a resolvability analysis of the moment tensor. The analysis targets common monitoring geometries employed in hydraulic fracturing in oil wells. Additionally, it is presented an application of sparse representation theory for the denoising of one-component and three-component microseismicity records, and an algorithm for improved automatic time-picking using non-linear inversion constraints.

  16. Transient ST segment depression during Holter monitoring: how to avoid false positive findings.

    PubMed

    Völler, H; Andresen, D; Brüggemann, T; Jereczek, M; Becker, B; Schröder, R

    1992-09-01

    To increase the specificity of 24-hour Holter monitoring in detecting transient myocardial ischemia, we separated genuine ST deviations from those dependent on artifacts by adding a detailed shape analysis of real-time printouts to the usual criteria of significant ST segment depression. We screened 116 apparently healthy subjects; 31 had to be excluded, because of pathologic findings in preliminary examinations. The remaining 85 (49 women and 36 men; mean age, 43.1 years) underwent Holter monitoring for assessment of the extent, frequency, and duration of episodes of horizontal and descending ST segment depression of at least 0.1 mV that persisted for at least 60 msec after the J point and that were at least 1 minute apart. On the basis of these criteria, six subjects (7.1%) showed 24 episodes of horizontal or descending ST segment depression with a mean of 0.2 mV (range, 0.15 to 0.25 mV), a frequency of four episodes per 24 hours (one to nine), and a duration of 12.2 minutes (range 3-range 41 minutes). Supplementary criteria--e.g., sudden onset of ST segment depression, identical orientation of PQ and ST segments, or simultaneous increase in R and P wave amplitude--made it possible to identify ST changes caused by artifacts in four volunteers. In only two subjects (2.4%) could true silent ischemia not be differentiated from false positive results. Thus consideration of only the extent, frequency, and duration of episodes does not permit a differentiation between true silent ischemia and false positive results. A supplementary shape analysis increases the specificity of ST segment analysis in detecting transient myocardial ischemia during 24-hour Holter monitoring.

  17. MULTIWAVELENGTH OBSERVATIONS OF 3C 454.3. II. THE AGILE 2007 DECEMBER CAMPAIGN

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Donnarumma, I.; Pucella, G.; Vittorini, V.

    2009-12-20

    We report on the second Astrorivelatore Gamma a Immagini Leggero (AGILE) multiwavelength campaign of the blazar 3C 454.3 during the first half of 2007 December. This campaign involved AGILE, Spitzer, Swift, Suzaku, the Whole Earth Blazar Telescope (WEBT) consortium, the Rapid Eye Mount (REM), and the Multicolor Imaging Telescopes for Survey and Monstrous Explosions (MITSuME) telescopes, offering a broadband coverage that allowed for a simultaneous sampling of the synchrotron and inverse Compton (IC) emissions. The two-week AGILE monitoring was accompanied by radio to optical monitoring by WEBT and REM, and by sparse observations in mid-infrared and soft/hard X-ray energy bandsmore » performed by means of Target of Opportunity observations by Spitzer, Swift, and Suzaku, respectively. The source was detected with an average flux of approx250 x 10{sup -8} photons cm{sup -2} s{sup -1} above 100 MeV, typical of its flaring states. The simultaneous optical and gamma-ray monitoring allowed us to study the time lag associated with the variability in the two energy bands, resulting in a possible approx

  18. Validation of Heart Rate Monitor Polar RS800 for Heart Rate Variability Analysis During Exercise.

    PubMed

    Hernando, David; Garatachea, Nuria; Almeida, Rute; Casajús, Jose A; Bailón, Raquel

    2018-03-01

    Hernando, D, Garatachea, N, Almeida, R, Casajús, JA, and Bailón, R. Validation of heart rate monitor Polar RS800 for heart rate variability analysis during exercise. J Strength Cond Res 32(3): 716-725, 2018-Heart rate variability (HRV) analysis during exercise is an interesting noninvasive tool to measure the cardiovascular response to the stress of exercise. Wearable heart rate monitors are a comfortable option to measure interbeat (RR) intervals while doing physical activities. It is necessary to evaluate the agreement between HRV parameters derived from the RR series recorded by wearable devices and those derived from an electrocardiogram (ECG) during dynamic exercise of low to high intensity. Twenty-three male volunteers performed an exercise stress test on a cycle ergometer. Subjects wore a Polar RS800 device, whereas ECG was also recorded simultaneously to extract the reference RR intervals. A time-frequency spectral analysis was performed to extract the instantaneous mean heart rate (HRM), and the power of low-frequency (PLF) and high-frequency (PHF) components, the latter centered on the respiratory frequency. Analysis was done in intervals of different exercise intensity based on oxygen consumption. Linear correlation, reliability, and agreement were computed in each interval. The agreement between the RR series obtained from the Polar device and from the ECG is high throughout the whole test although the shorter the RR is, the more differences there are. Both methods are interchangeable when analyzing HRV at rest. At high exercise intensity, HRM and PLF still presented a high correlation (ρ > 0.8) and excellent reliability and agreement indices (above 0.9). However, the PHF measurements from the Polar showed reliability and agreement coefficients around 0.5 or lower when the level of the exercise increases (for levels of O2 above 60%).

  19. Accuracy of continuous noninvasive arterial pressure monitoring in living-liver donors during transplantation.

    PubMed

    Araz, Coskun; Zeyneloglu, Pinar; Pirat, Arash; Veziroglu, Nukhet; Camkiran Firat, Aynur; Arslan, Gulnaz

    2015-04-01

    Hemodynamic monitoring is vital during liver transplant surgeries because distinct hemodynamic changes are expected. The continuous noninvasive arterial pressure (CNAP) monitor is a noninvasive device for continuous arterial pressure measurement by a tonometric method. This study compared continuous noninvasive arterial pressure monitoring with invasive direct arterial pressure monitoring in living-liver donors during transplant. There were 40 patients analyzed while undergoing hepatic lobectomy for liver transplant. Invasive pressure monitoring was established at the radial artery and continuous noninvasive arterial pressure monitoring using a finger sensor was recorded simultaneously from the contralateral arm. Systolic, diastolic, and mean arterial pressures from the 2 methods were compared. Correlation between the 2 methods was calculated. A total of 5433 simultaneous measurements were obtained. For systolic arterial blood pressure, 55% continuous noninvasive arterial pressure measurements were within 10% direct arterial measurement; the correlation was 0.479, continuous noninvasive arterial pressure bias was -0.3 mm Hg, and limits of agreement were 32.0 mm Hg. For diastolic arterial blood pressure, 50% continuous noninvasive arterial pressure measurements were within 10% direct arterial measurement; the correlation was 0.630, continuous noninvasive arterial pressure bias was -0.4 mm Hg, and limits of agreement were 21.1 mm Hg. For mean arterial blood pressure, 60% continuous noninvasive arterial pressure measurements were within 10% direct arterial measurement; the correlation was 0.692, continuous noninvasive arterial pressure bias was +0.4 mm Hg, and limits of agreement were 20.8 mm Hg. The 2 monitoring techniques did not show acceptable agreement. Our results suggest that continuous noninvasive arterial pressure monitoring is not equivalent to invasive arterial pressure monitoring in donors during living-donor liver transplant.

  20. Digital Pitch-And-Roll Monitor

    NASA Technical Reports Server (NTRS)

    Finley, Tom D.; Brown, Jeff; Campbell, Ryland

    1991-01-01

    Highly accurate inclinometer developed. Monitors both pitch and roll simultaneously and provides printed output on demand. Includes three mutually perpendicular accelerometers and signal-conditioning circuitry converting outputs of sensors to digital values of pitch and roll. In addition to wind-tunnel applications, system useful in any application involving steady-state, precise sensing of angles, such as calibration of robotic devices and positioners.

  1. Turbulence Environment Characterization

    DTIC Science & Technology

    1979-06-01

    of ro is consistent with the simultaneous measurement made with the Seeing Monitor. An average turbulent profile developed primarily from microthermal ...data. The operation of the routine meteorological instrumentation, microthermal probes, acoustic sounder, Seeing Monitor and Star Sensor have been...and J. Spencer of RADC gave sub- stantial support and assistance with the microthermal probes, acoustic sounder and PDP-8 software. We acknowledge R

  2. Membrane Potential and Calcium Dynamics in Beta Cells from Mouse Pancreas Tissue Slices: Theory, Experimentation, and Analysis.

    PubMed

    Dolenšek, Jurij; Špelič, Denis; Klemen, Maša Skelin; Žalik, Borut; Gosak, Marko; Rupnik, Marjan Slak; Stožer, Andraž

    2015-10-28

    Beta cells in the pancreatic islets of Langerhans are precise biological sensors for glucose and play a central role in balancing the organism between catabolic and anabolic needs. A hallmark of the beta cell response to glucose are oscillatory changes of membrane potential that are tightly coupled with oscillatory changes in intracellular calcium concentration which, in turn, elicit oscillations of insulin secretion. Both membrane potential and calcium changes spread from one beta cell to the other in a wave-like manner. In order to assess the properties of the abovementioned responses to physiological and pathological stimuli, the main challenge remains how to effectively measure membrane potential and calcium changes at the same time with high spatial and temporal resolution, and also in as many cells as possible. To date, the most wide-spread approach has employed the electrophysiological patch-clamp method to monitor membrane potential changes. Inherently, this technique has many advantages, such as a direct contact with the cell and a high temporal resolution. However, it allows one to assess information from a single cell only. In some instances, this technique has been used in conjunction with CCD camera-based imaging, offering the opportunity to simultaneously monitor membrane potential and calcium changes, but not in the same cells and not with a reliable cellular or subcellular spatial resolution. Recently, a novel family of highly-sensitive membrane potential reporter dyes in combination with high temporal and spatial confocal calcium imaging allows for simultaneously detecting membrane potential and calcium changes in many cells at a time. Since the signals yielded from both types of reporter dyes are inherently noisy, we have developed complex methods of data denoising that permit for visualization and pixel-wise analysis of signals. Combining the experimental approach of high-resolution imaging with the advanced analysis of noisy data enables novel physiological insights and reassessment of current concepts in unprecedented detail.

  3. Simultaneous estimation of local-scale and flow path-scale dual-domain mass transfer parameters using geoelectrical monitoring

    USGS Publications Warehouse

    Briggs, Martin A.; Day-Lewis, Frederick D.; Ong, John B.; Curtis, Gary P.; Lane, John W.

    2013-01-01

    Anomalous solute transport, modeled as rate-limited mass transfer, has an observable geoelectrical signature that can be exploited to infer the controlling parameters. Previous experiments indicate the combination of time-lapse geoelectrical and fluid conductivity measurements collected during ionic tracer experiments provides valuable insight into the exchange of solute between mobile and immobile porosity. Here, we use geoelectrical measurements to monitor tracer experiments at a former uranium mill tailings site in Naturita, Colorado. We use nonlinear regression to calibrate dual-domain mass transfer solute-transport models to field data. This method differs from previous approaches by calibrating the model simultaneously to observed fluid conductivity and geoelectrical tracer signals using two parameter scales: effective parameters for the flow path upgradient of the monitoring point and the parameters local to the monitoring point. We use regression statistics to rigorously evaluate the information content and sensitivity of fluid conductivity and geophysical data, demonstrating multiple scales of mass transfer parameters can simultaneously be estimated. Our results show, for the first time, field-scale spatial variability of mass transfer parameters (i.e., exchange-rate coefficient, porosity) between local and upgradient effective parameters; hence our approach provides insight into spatial variability and scaling behavior. Additional synthetic modeling is used to evaluate the scope of applicability of our approach, indicating greater range than earlier work using temporal moments and a Lagrangian-based Damköhler number. The introduced Eulerian-based Damköhler is useful for estimating tracer injection duration needed to evaluate mass transfer exchange rates that range over several orders of magnitude.

  4. Simultaneous monitoring of insulin and islet amyloid polypeptide secretion from islets of Langerhans on a microfluidic device.

    PubMed

    Lomasney, Anna R; Yi, Lian; Roper, Michael G

    2013-08-20

    A method was developed that allowed simultaneous monitoring of the acute secretory dynamics of insulin and islet amyloid polypeptide (IAPP) from islets of Langerhans using a microfluidic system with two-color detection. A flow-switching feature enabled changes in the perfusion media within 5 s, allowing rapid exchange of the glucose concentrations delivered to groups of islets. The perfusate was continuously sampled by electroosmotic flow and mixed online with Cy5-labeled insulin, fluorescein isothiocyanate (FITC)-labeled IAPP, anti-insulin, and anti-IAPP antibodies in an 8.15 cm mixing channel maintained at 37 °C. The immunoassay mixture was injected for 0.3 s onto a 1.5 cm separation channel at 11.75 s intervals and immunoassay reagents detected using 488 and 635 nm lasers with two independent photomultiplier tubes for detection of the FITC and Cy5 signal. RSD of the bound-to-free immunoassay ratios ranged from 2 to 7% with LODs of 20 nM for insulin and 1 nM for IAPP. Simultaneous secretion profiles of the two peptides were monitored from groups of 4-10 islets during multiple step changes in glucose concentration. Insulin and IAPP were secreted in an approximately 10:1 ratio and displayed similar responses to step changes from 3 to 11 or 20 mM glucose. The ability to monitor the secretory dynamics of multiple peptides from islets of Langerhans in a highly automated fashion is expected to be a useful tool for investigating hormonal regulation of glucose homeostasis.

  5. With or without spikes: localization of focal epileptic activity by simultaneous electroencephalography and functional magnetic resonance imaging

    PubMed Central

    Grouiller, Frédéric; Thornton, Rachel C.; Groening, Kristina; Spinelli, Laurent; Duncan, John S.; Schaller, Karl; Siniatchkin, Michael; Lemieux, Louis; Seeck, Margitta; Michel, Christoph M.

    2011-01-01

    In patients with medically refractory focal epilepsy who are candidates for epilepsy surgery, concordant non-invasive neuroimaging data are useful to guide invasive electroencephalographic recordings or surgical resection. Simultaneous electroencephalography and functional magnetic resonance imaging recordings can reveal regions of haemodynamic fluctuations related to epileptic activity and help localize its generators. However, many of these studies (40–70%) remain inconclusive, principally due to the absence of interictal epileptiform discharges during simultaneous recordings, or lack of haemodynamic changes correlated to interictal epileptiform discharges. We investigated whether the presence of epilepsy-specific voltage maps on scalp electroencephalography correlated with haemodynamic changes and could help localize the epileptic focus. In 23 patients with focal epilepsy, we built epilepsy-specific electroencephalographic voltage maps using averaged interictal epileptiform discharges recorded during long-term clinical monitoring outside the scanner and computed the correlation of this map with the electroencephalographic recordings in the scanner for each time frame. The time course of this correlation coefficient was used as a regressor for functional magnetic resonance imaging analysis to map haemodynamic changes related to these epilepsy-specific maps (topography-related haemodynamic changes). The method was first validated in five patients with significant haemodynamic changes correlated to interictal epileptiform discharges on conventional analysis. We then applied the method to 18 patients who had inconclusive simultaneous electroencephalography and functional magnetic resonance imaging studies due to the absence of interictal epileptiform discharges or absence of significant correlated haemodynamic changes. The concordance of the results with subsequent intracranial electroencephalography and/or resection area in patients who were seizure free after surgery was assessed. In the validation group, haemodynamic changes correlated to voltage maps were similar to those obtained with conventional analysis in 5/5 patients. In 14/18 patients (78%) with previously inconclusive studies, scalp maps related to epileptic activity had haemodynamic correlates even when no interictal epileptiform discharges were detected during simultaneous recordings. Haemodynamic changes correlated to voltage maps were spatially concordant with intracranial electroencephalography or with the resection area. We found better concordance in patients with lateral temporal and extratemporal neocortical epilepsy compared to medial/polar temporal lobe epilepsy, probably due to the fact that electroencephalographic voltage maps specific to lateral temporal and extratemporal epileptic activity are more dissimilar to maps of physiological activity. Our approach significantly increases the yield of simultaneous electroencephalography and functional magnetic resonance imaging to localize the epileptic focus non-invasively, allowing better targeting for surgical resection or implantation of intracranial electrode arrays. PMID:21752790

  6. Storage element performance optimization for CMS analysis jobs

    NASA Astrophysics Data System (ADS)

    Behrmann, G.; Dahlblom, J.; Guldmyr, J.; Happonen, K.; Lindén, T.

    2012-12-01

    Tier-2 computing sites in the Worldwide Large Hadron Collider Computing Grid (WLCG) host CPU-resources (Compute Element, CE) and storage resources (Storage Element, SE). The vast amount of data that needs to processed from the Large Hadron Collider (LHC) experiments requires good and efficient use of the available resources. Having a good CPU efficiency for the end users analysis jobs requires that the performance of the storage system is able to scale with I/O requests from hundreds or even thousands of simultaneous jobs. In this presentation we report on the work on improving the SE performance at the Helsinki Institute of Physics (HIP) Tier-2 used for the Compact Muon Experiment (CMS) at the LHC. Statistics from CMS grid jobs are collected and stored in the CMS Dashboard for further analysis, which allows for easy performance monitoring by the sites and by the CMS collaboration. As part of the monitoring framework CMS uses the JobRobot which sends every four hours 100 analysis jobs to each site. CMS also uses the HammerCloud tool for site monitoring and stress testing and it has replaced the JobRobot. The performance of the analysis workflow submitted with JobRobot or HammerCloud can be used to track the performance due to site configuration changes, since the analysis workflow is kept the same for all sites and for months in time. The CPU efficiency of the JobRobot jobs at HIP was increased approximately by 50 % to more than 90 %, by tuning the SE and by improvements in the CMSSW and dCache software. The performance of the CMS analysis jobs improved significantly too. Similar work has been done on other CMS Tier-sites, since on average the CPU efficiency for CMSSW jobs has increased during 2011. Better monitoring of the SE allows faster detection of problems, so that the performance level can be kept high. The next storage upgrade at HIP consists of SAS disk enclosures which can be stress tested on demand with HammerCloud workflows, to make sure that the I/O-performance is good.

  7. Simultaneous Ultrasound Therapy and Monitoring of Microbubble-Seeded Acoustic Cavitation Using a Single-Element Transducer.

    PubMed

    Heymans, Sophie V; Martindale, Christine F; Suler, Andrej; Pouliopoulos, Antonios N; Dickinson, Robert J; Choi, James J

    2017-08-01

    Ultrasound-driven microbubble (MB) activity is used in therapeutic applications such as blood clot dissolution and targeted drug delivery. The safety and performance of these technologies are linked to the type and distribution of MB activities produced within the targeted area, but controlling and monitoring these activities in vivo and in real time has proven to be difficult. As therapeutic pulses are often milliseconds long, MB monitoring currently requires a separate transducer used in a passive reception mode. Here, we present a simple, inexpensive, integrated setup, in which a focused single-element transducer can perform ultrasound therapy and monitoring simultaneously. MBs were made to flow through a vessel-mimicking tube, placed within the transducer's focus, and were sonicated with therapeutic pulses (peak rarefactional pressure: 75-827 kPa, pulse lengths: [Formula: see text] and 20 ms). The MB-seeded acoustic emissions were captured using the same transducer. The received signals were separated from the therapeutic signal with a hybrid coupler and a high-pass filter. We discriminated the MB-generated cavitation signal from the primary acoustic field and characterized MB behavior in real time. The simplicity and versatility of our circuit could make existing single-element therapeutic transducers also act as cavitation detectors, allowing the production of compact therapeutic systems with real time monitoring capabilities.

  8. Near infrared spectroscopy combined with multivariate analysis for monitoring the ethanol precipitation process of fraction I + II + III supernatant in human albumin separation

    NASA Astrophysics Data System (ADS)

    Li, Can; Wang, Fei; Zang, Lixuan; Zang, Hengchang; Alcalà, Manel; Nie, Lei; Wang, Mingyu; Li, Lian

    2017-03-01

    Nowadays, as a powerful process analytical tool, near infrared spectroscopy (NIRS) has been widely applied in process monitoring. In present work, NIRS combined with multivariate analysis was used to monitor the ethanol precipitation process of fraction I + II + III (FI + II + III) supernatant in human albumin (HA) separation to achieve qualitative and quantitative monitoring at the same time and assure the product's quality. First, a qualitative model was established by using principal component analysis (PCA) with 6 of 8 normal batches samples, and evaluated by the remaining 2 normal batches and 3 abnormal batches. The results showed that the first principal component (PC1) score chart could be successfully used for fault detection and diagnosis. Then, two quantitative models were built with 6 of 8 normal batches to determine the content of the total protein (TP) and HA separately by using partial least squares regression (PLS-R) strategy, and the models were validated by 2 remaining normal batches. The determination coefficient of validation (Rp2), root mean square error of cross validation (RMSECV), root mean square error of prediction (RMSEP) and ratio of performance deviation (RPD) were 0.975, 0.501 g/L, 0.465 g/L and 5.57 for TP, and 0.969, 0.530 g/L, 0.341 g/L and 5.47 for HA, respectively. The results showed that the established models could give a rapid and accurate measurement of the content of TP and HA. The results of this study indicated that NIRS is an effective tool and could be successfully used for qualitative and quantitative monitoring the ethanol precipitation process of FI + II + III supernatant simultaneously. This research has significant reference value for assuring the quality and improving the recovery ratio of HA in industrialization scale by using NIRS.

  9. Near infrared spectroscopy combined with multivariate analysis for monitoring the ethanol precipitation process of fraction I+II+III supernatant in human albumin separation.

    PubMed

    Li, Can; Wang, Fei; Zang, Lixuan; Zang, Hengchang; Alcalà, Manel; Nie, Lei; Wang, Mingyu; Li, Lian

    2017-03-15

    Nowadays, as a powerful process analytical tool, near infrared spectroscopy (NIRS) has been widely applied in process monitoring. In present work, NIRS combined with multivariate analysis was used to monitor the ethanol precipitation process of fraction I+II+III (FI+II+III) supernatant in human albumin (HA) separation to achieve qualitative and quantitative monitoring at the same time and assure the product's quality. First, a qualitative model was established by using principal component analysis (PCA) with 6 of 8 normal batches samples, and evaluated by the remaining 2 normal batches and 3 abnormal batches. The results showed that the first principal component (PC1) score chart could be successfully used for fault detection and diagnosis. Then, two quantitative models were built with 6 of 8 normal batches to determine the content of the total protein (TP) and HA separately by using partial least squares regression (PLS-R) strategy, and the models were validated by 2 remaining normal batches. The determination coefficient of validation (R p 2 ), root mean square error of cross validation (RMSECV), root mean square error of prediction (RMSEP) and ratio of performance deviation (RPD) were 0.975, 0.501g/L, 0.465g/L and 5.57 for TP, and 0.969, 0.530g/L, 0.341g/L and 5.47 for HA, respectively. The results showed that the established models could give a rapid and accurate measurement of the content of TP and HA. The results of this study indicated that NIRS is an effective tool and could be successfully used for qualitative and quantitative monitoring the ethanol precipitation process of FI+II+III supernatant simultaneously. This research has significant reference value for assuring the quality and improving the recovery ratio of HA in industrialization scale by using NIRS. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Automated multivariate analysis of multi-sensor data submitted online: Real-time environmental monitoring.

    PubMed

    Eide, Ingvar; Westad, Frank

    2018-01-01

    A pilot study demonstrating real-time environmental monitoring with automated multivariate analysis of multi-sensor data submitted online has been performed at the cabled LoVe Ocean Observatory located at 258 m depth 20 km off the coast of Lofoten-Vesterålen, Norway. The major purpose was efficient monitoring of many variables simultaneously and early detection of changes and time-trends in the overall response pattern before changes were evident in individual variables. The pilot study was performed with 12 sensors from May 16 to August 31, 2015. The sensors provided data for chlorophyll, turbidity, conductivity, temperature (three sensors), salinity (calculated from temperature and conductivity), biomass at three different depth intervals (5-50, 50-120, 120-250 m), and current speed measured in two directions (east and north) using two sensors covering different depths with overlap. A total of 88 variables were monitored, 78 from the two current speed sensors. The time-resolution varied, thus the data had to be aligned to a common time resolution. After alignment, the data were interpreted using principal component analysis (PCA). Initially, a calibration model was established using data from May 16 to July 31. The data on current speed from two sensors were subject to two separate PCA models and the score vectors from these two models were combined with the other 10 variables in a multi-block PCA model. The observations from August were projected on the calibration model consecutively one at a time and the result was visualized in a score plot. Automated PCA of multi-sensor data submitted online is illustrated with an attached time-lapse video covering the relative short time period used in the pilot study. Methods for statistical validation, and warning and alarm limits are described. Redundant sensors enable sensor diagnostics and quality assurance. In a future perspective, the concept may be used in integrated environmental monitoring.

  11. Identification and simultaneous quantification of five alkaloids in Piper longum L. by HPLC-ESI-MS(n) and UFLC-ESI-MS/MS and their application to Piper nigrum L.

    PubMed

    Liu, Hao-Long; Luo, Rong; Chen, Xiao-Qing; Ba, Yin-Ying; Zheng, Li; Guo, Wei-Wei; Wu, Xia

    2015-06-15

    A simple, effective and suitable UFLC-ESI-MS/MS method was firstly developed to simultaneously determine five characteristic constituents (piperine, piperlonguminine, Δα,β-dihydropiperlonguminine, pellitorine and piperanine) of Piper longum L. The total alkaloids of P. longum L. was prepared. The alkaloid contents of Piper nigrum L. and P. longum L. were compared. The analysis was carried out in multiple reaction monitoring scan mode. The method showed a good specificity, linearity (R(2)>0.995), stability (RSD<2.53%), repeatability (RSD<2.58%), and recovery (90.0-103.5%). The limits of detection and limits of quantification of five alkaloids were in the range of 0.02-0.03 and 0.05-0.10 ng/mL, respectively. The intra- and inter-day precision was less than 9.30% and 9.55%, respectively. The validation results confirmed that the method could simultaneously determine the target alkaloids in the sample. Furthermore, the identities of the alkaloids were verified by HPLC-ESI-MS/MS. Compared with P. nigrum, P. longum had lower piperine content but was enriched in the other four alkaloids. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Simultaneous LC-MS/MS determination of phenylbutyrate, phenylacetate benzoate and their corresponding metabolites phenylacetylglutamine and hippurate in blood and urine.

    PubMed

    Laryea, Maurice D; Herebian, Diran; Meissner, Thomas; Mayatepek, Ertan

    2010-12-01

    Inborn errors of urea metabolism result in hyperammonemia. Treatment of urea cycle disorders can effectively lower plasma ammonium levels and results in survival in the majority of patients. Available medications for treating urea cycle disorders include sodium benzoate (BA), sodium phenylacetate (PAA), and sodium phenylbutyrate (PBA) and are given to provide alternate routes for disposition of waste nitrogen excretion. In this study, we develop and validate a liquid chromatography tandem mass spectrometry (LC-MS/MS) method for simultaneous determination of benzoic acid, phenylacetic acid, phenylbutyric acid, phenylacetylglutamine, and hippuric acid in plasma and urine from children with inborn errors of urea synthesis. Plasma extracts and diluted urine samples were injected on a reverse-phase column and identified and quantified by selected reaction monitoring (SRM) in negative ion mode. Deuterated analogues served as internal standards. Analysis time was 7 min. Assay precision, accuracy, and linearity and sample stability were determined using enriched samples. Quantification limits of the method were 100 ng/ml (0.3-0.8 μmol/L) for all analytes, and recoveries were >90%. Inter- and intraday relative standard deviations were <10%. Our newly developed LC-MS/MS represents a robust, sensitive, and rapid method that allows simultaneous determination of the five compounds in plasma and urine.

  13. A biofilm microreactor system for simultaneous electrochemical and nuclear magnetic resonance techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Renslow, Ryan S.; Babauta, Jerome T.; Majors, Paul D.

    2014-03-01

    In order to fully understand electrochemically active biofilms and the limitations to their scale-up in industrial biofilm reactors, a complete picture of the microenvironments inside the biofilm is needed. Nuclear magnetic resonance (NMR) techniques are ideally suited for the study of biofilms and for probing their microenvironments because these techniques allow for non-invasive interrogation and in situ monitoring with high resolution. By combining NMR with simultaneous electrochemical techniques, it is possible to sustain and study live electrochemically active biofilms. Here, we introduce a novel biofilm microreactor system that allows for simultaneous electrochemical and NMR techniques (EC-NMR) at the microscale. Microreactorsmore » were designed with custom radiofrequency resonator coils, which allowed for NMR measurements of biofilms growing on polarized gold electrodes. For an example application of this system, we grew Geobacter sulfurreducens biofilms. NMR was used to investigate growth media flow velocities, which were compared to simulated laminar flow, and electron donor concentrations inside the biofilms. We use Monte Carlo error analysis to estimate standard deviations of the electron donor concentration measurements within the biofilm. The EC-NMR biofilm microreactor system can ultimately be used to correlate extracellular electron transfer rates with metabolic reactions and explore extracellular electron transfer mechanisms.« less

  14. Development and validation of an HPLC method for simultaneous determination of trimethoprim and sulfamethoxazole in human plasma.

    PubMed

    Sayar, Esin; Sahin, Selma; Cevheroglu, Semsettin; Hincal, A Atilla

    2010-09-01

    The combination of trimethoprim (TMP) and sulfamethoxazole (SMX) is used in the treatment of many common infections such as urinary, respiratory and gastrointestinal tract infections. The aim of this study was to determine TMP and SMX simultaneously in human plasma samples by high performance liquid chromatography (HPLC) using antipyrine as the internal standard. Separation of the compounds was achieved on a reverse-phase C8 column packed with 5 microm dimethyl octadecylsilyl bonded amorphous silica (4.6 mm x 250 mm) column using a mobile phase consisted of potassium hydrogen phosphate, acetonitrile, methanol and water adjusted to pH 6.2. The mobile phase was delivered at a flow rate of 1 mL min- and the effluent was monitored using Max plot technique at 25 derees C. Retention times were 5 min for TMP, 7 min for antipyrine and 9 min for SMX. Quantitation limits were 10 ng mL(-1) for TMP and 50 ng mL(-1) for SMX. Our findings indicated that the developed HPLC method was precise, accurate, specific and sensitive for simultaneous determination of TMP and SMX. Proposed HPLC method was successfully applied for the analysis of TMP and SMX in human plasma after oral administration of a co-trimoxazole tablet to human volunteers.

  15. Increased skin and mucosal toxicity in the combination of vemurafenib with radiation therapy.

    PubMed

    Merten, Ricarda; Hecht, Markus; Haderlein, Marlen; Distel, Luitpold; Fietkau, Rainer; Heinzerling, Lucie; Semrau, Sabine

    2014-11-01

    Palliative radiotherapy is often required for patients with metastatic malignant melanoma in the case of bone or brain metastases. Since BRAF inhibitor therapy is highly efficient in V600-mutated melanomas, there is hesitation to stop it during radiotherapy. Consequently, radiotherapy under simultaneous vemurafenib treatment is frequently needed. We report the case of a patient receiving palliative radiotherapy of spinal bone metastases before and during vemurafenib therapy. The skin reactions were quantitatively scored using computer-assisted digital image evaluation. Radiotherapy without vemurafenib was tolerated very well, whereas radiotherapy under simultaneous vemurafenib treatment resulted in accentuated skin reactions. Furthermore, the patient developed dysphagia and had to be hospitalized for parenteral nutrition. In the quantitative analysis, there was a twofold increase in pigmentation and erythema of the irradiated skin area of the thoracic spine when vemurafenib was combined with radiotherapy compared with radiotherapy treatment alone. This is the first reported case of a patient showing no complications during radiotherapy without vemurafenib but remarkable skin and mucosal toxicity under concurrent vemurafenib therapy. Thus, a genetically conditioned individually elevated radiosensitivity can definitely be excluded. Compared with other reported cases, radiosensitization was not limited to the skin, but also affected the esophageal mucosa. Vemurafenib is a strong radiosensitizer. Patients receiving radiotherapy under simultaneous vemurafenib treatment should be monitored very closely.

  16. Clustering ENTLN sferics to improve TGF temporal analysis

    NASA Astrophysics Data System (ADS)

    Pradhan, E.; Briggs, M. S.; Stanbro, M.; Cramer, E.; Heckman, S.; Roberts, O.

    2017-12-01

    Using TGFs detected with Fermi Gamma-ray Burst Monitor (GBM) and simultaneous radio sferics detected by Earth Network Total Lightning Network (ENTLN), we establish a temporal co-relation between them. The first step is to find ENTLN strokes that that are closely associated to GBM TGFs. We then identify all the related strokes in the lightning flash that the TGF-associated-stroke belongs to. After trying several algorithms, we found out that the DBSCAN clustering algorithm was best for clustering related ENTLN strokes into flashes. The operation of DBSCAN was optimized using a single seperation measure that combined time and distance seperation. Previous analysis found that these strokes show three timescales with respect to the gamma-ray time. We will use the improved identification of flashes to research this.

  17. An Integrated Hot-Stage Microscope-Direct Analysis in Real Time-Mass Spectrometry System for Studying the Thermal Behavior of Materials.

    PubMed

    Ashton, Gage P; Harding, Lindsay P; Parkes, Gareth M B

    2017-12-19

    This paper describes a new analytical instrument that combines a precisely temperature-controlled hot-stage with digital microscopy and Direct Analysis in Real Time-mass spectrometry (DART-MS) detection. The novelty of the instrument lies in its ability to monitor processes as a function of temperature through the simultaneous recording of images, quantitative color changes, and mass spectra. The capability of the instrument was demonstrated through successful application to four very varied systems including profiling an organic reaction, decomposition of silicone polymers, and the desorption of rhodamine B from an alumina surface. The multidimensional, real-time analytical data provided by this instrument allow for a much greater insight into thermal processes than could be achieved previously.

  18. Discovery of VHE γ -rays from the blazar 1ES 1215+303 with the MAGIC telescopes and simultaneous multi-wavelength observations

    DOE PAGES

    Aleksić, J.; Alvarez, E. A.; Antonelli, L. A.; ...

    2012-08-15

    Here, we present the discovery of very high energy (VHE, E > 100 GeV) γ-ray emission from the BL Lac object 1ES 1215+303 by the MAGIC telescopes and simultaneous multi-wavelength data in a broad energy range from radio to γ-rays. We also study the VHE γ-ray emission from 1ES 1215+303 and its relation to the emissions in other wavelengths. Triggered by an optical outburst, MAGIC observed the source in 2011 January - February for 20.3 h. The target was monitored in the optical R-band by the KVA telescope that also performed optical polarization measurements. Furthermore, we triggered target of opportunitymore » observations with the Swift satellite and obtained simultaneous and quasi-simultaneous data from the Fermi Large Area Telescope and from the Metsähovi radio telescope. We also present the analysis of older MAGIC data taken in 2010. The MAGIC observations of 1ES 1215+303 carried out in 2011 January - February resulted in the first detection of the source at VHE with a statistical significance of 9.4σ. Simultaneously, the source was observed in a high optical and X-ray state. In 2010 the source was observed in a lower state in optical, X-ray, and VHE, while the GeV γ-ray flux and the radio flux were comparable in 2010 and 2011. The spectral energy distribution obtained with the 2011 data can be modeled with a simple one zone SSC model, but it requires extreme values for the Doppler factor or the electron energy distribution.« less

  19. Quantification of multiple simultaneously occurring nitrogen flows in the euphotic ocean

    NASA Astrophysics Data System (ADS)

    Xu, Min Nina; Wu, Yanhua; Zheng, Li Wei; Zheng, Zhenzhen; Zhao, Huade; Laws, Edward A.; Kao, Shuh-Ji

    2017-03-01

    The general features of the N cycle in the sunlit region of the ocean are well known, but methodological difficulties have previously confounded simultaneous quantification of transformation rates among the many different forms of N, e.g., ammonium (NH4+), nitrite (NO2-), nitrate (NO3-), and particulate/dissolved organic nitrogen (PN/DON). However, recent advances in analytical methodology have made it possible to employ a convenient isotope labeling technique to quantify in situ fluxes among oft-measured nitrogen species within the euphotic zone. Addition of a single 15N-labeled NH4+ tracer and monitoring of the changes in the concentrations and isotopic compositions of the total dissolved nitrogen (TDN), PN, NH4+, NO2-, and NO3- pools allowed us to quantify the 15N and 14N fluxes simultaneously. Constraints expressing the balance of 15N and 14N fluxes between the different N pools were expressed in the form of simultaneous equations, the unique solution of which via matrix inversion yielded the relevant N fluxes, including rates of NH4+, NO2-, and NO3- uptake; ammonia oxidation; nitrite oxidation; DON release; and NH4+ uptake by bacteria. The matrix inversion methodology that we used was designed specifically to analyze the results of incubations under simulated in situ conditions in the euphotic zone. By taking into consideration simultaneous fluxes among multiple N pools, we minimized potential artifacts caused by non-targeted processes in traditional source-product methods. The proposed isotope matrix method facilitates post hoc analysis of data from on-deck incubation experiments and can be used to probe effects of environmental factors (e.g., pH, temperature, and light) on multiple processes under controlled conditions.

  20. Simultaneous quantitation of acetylsalicylic acid and clopidogrel along with their metabolites in human plasma using liquid chromatography tandem mass spectrometry.

    PubMed

    Chhonker, Yashpal S; Pandey, Chandra P; Chandasana, Hardik; Laxman, Tulsankar Sachin; Prasad, Yarra Durga; Narain, V S; Dikshit, Madhu; Bhatta, Rabi S

    2016-03-01

    The interest in therapeutic drug monitoring has increased over the last few years. Inter- and intra-patient variability in pharmacokinetics, plasma concentration related toxicity and success of therapy have stressed the need of frequent therapeutic drug monitoring of the drugs. A sensitive, selective and rapid liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) method was developed for the simultaneous quantification of acetylsalicylic acid (aspirin), salicylic acid, clopidogrel and carboxylic acid metabolite of clopidogrel in human plasma. The chromatographic separations were achieved on Waters Symmetry Shield(TM) C18 column (150 × 4.6 mm, 5 µm) using 3.5 mm ammonium acetate (pH 3.5)-acetonitrile (10:90, v/v) as mobile phase at a flow rate of 0.75 mL/min. The present method was successfully applied for therapeutic drug monitoring of aspirin and clopidogrel in 67 patients with coronary artery disease. Copyright © 2015 John Wiley & Sons, Ltd.

  1. Acoustic transducer for nuclear reactor monitoring

    DOEpatents

    Ahlgren, Frederic F.; Scott, Paul F.

    1977-01-01

    A transducer to monitor a parameter and produce an acoustic signal from which the monitored parameter can be recovered. The transducer comprises a modified Galton whistle which emits a narrow band acoustic signal having a frequency dependent upon the parameter being monitored, such as the temperature of the cooling media of a nuclear reactor. Multiple locations within a reactor are monitored simultaneously by a remote acoustic receiver by providing a plurality of transducers each designed so that the acoustic signal it emits has a frequency distinct from the frequencies of signals emitted by the other transducers, whereby each signal can be unambiguously related to a particular transducer.

  2. Applicability of the new 60 μm polyethylene glycol solid-phase microextraction fiber assembly for the simultaneous analysis of six pesticides in water.

    PubMed

    Pereira, Ana; Silva, Emília; Cerejeira, Maria J

    2014-01-01

    A solid-phase microextraction (SPME) method has been applied for the simultaneous analysis of six pesticides in water, with polar to moderately polar range, by gas chromatography-mass spectrometry (GC-MS). Two types of fiber coatings [60 µm polyethylene glycol (PEG) and 65 µm polydimethylsiloxane/divinylbenzene (PDMS/DVB)] and the effect of salt (addition of 10 and 25% of NaCl) were compared. The extraction efficiency was higher with PEG than with the PDMS/DVB fiber for all pesticides, with the exception of terbuthylazine and phosmet, and with addition of 25% NaCl. The optimized SPME-GC-MS method, adopting the PEG fiber and the addition of 25% NaCl, in addition to other conditions [60 min of direct dipping of the fiber into the water sample (10 mL) under agitation (250 rpm) at ambient temperature; desorption period of 5 min at 240°C] allowed the determination of all studied pesticides and showed good linearity for concentrations ranging from 0.05 to 5 µg/L. Limits of detection varied between 0.003 and 0.145 µg/L, with values below 0.025 µg/L for most of the analytes. Precision ranged from 4.2 to 12%. The proposed method is fast and simple, and was proven to be reliable for the routine analysis of pesticides in water, primarily for environmental monitoring.

  3. [Simultaneous analysis of four diuretic drugs by HPLC and its application to health food supplements advertising weight reduction].

    PubMed

    Goto, Tomomi; Mikami, Eiichi; Ohno, Tsutomu; Matsumoto, Hiroshi

    2002-04-01

    A high-performance liquid chromatographic (HPLC) method for the simultaneous analysis of triamterene, trichlormethiazide, furosemide and spironolactone is presented for application in the examination of health food supplements advertising weight reduction and in the analysis of pharmaceuticals. The HPLC assay was performed under gradient conditions using a Wakosil ODS 5C18 column (5 microns, 150 x 4.6 mm i.d.). The mobile phase consisted of a gradient program with a mixture of water and acetonitrile containing 0.1% triethylamine adjusted with phosphoric acid to pH 3.0: from 0 to 6 min, 15% acetonitrile; from 6 to 20 min, linear gradient from 15 to 50% acetonitrile; and from 20 to 40 min, 50% acetonitrile. The column effluent was monitored from 0 to 20 min at 260 nm and from 20 to 40 min at 235 nm. The calibration curves of the four drugs showed good linearity and the correlation coefficients were better than 0.999 in all cases. The lower limits of detection were approximately 40 ng for each drug. Commercially available health food supplements and pharmaceuticals were analyzed after extraction with a mixture of methanol and acetic acid (99:1). The procedure described here is suitable for the screening of four diuretic drugs in adulterated supplements and for the quality control of pharmaceuticals with minimal sample preparation.

  4. Simultaneous analysis of 11 main active components in Cirsium setosum based on HPLC-ESI-MS/MS and combined with statistical methods.

    PubMed

    Sun, Qian; Chang, Lu; Ren, Yanping; Cao, Liang; Sun, Yingguang; Du, Yingfeng; Shi, Xiaowei; Wang, Qiao; Zhang, Lantong

    2012-11-01

    A novel method based on high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry was developed for simultaneous determination of the 11 major active components including ten flavonoids and one phenolic acid in Cirsium setosum. Separation was performed on a reversed-phase C(18) column with gradient elution of methanol and 0.1‰ acetic acid (v/v). The identification and quantification of the analytes were achieved on a hybrid quadrupole linear ion trap mass spectrometer. Multiple-reaction monitoring scanning was employed for quantification with switching electrospray ion source polarity between positive and negative modes in a single run. Full validation of the assay was carried out including linearity, precision, accuracy, stability, limits of detection and quantification. The results demonstrated that the method developed was reliable, rapid, and specific. The 25 batches of C. setosum samples from different sources were first determined using the developed method and the total contents of 11 analytes ranged from 1717.460 to 23028.258 μg/g. Among them, the content of linarin was highest, and its mean value was 7340.967 μg/g. Principal component analysis and hierarchical clustering analysis were performed to differentiate and classify the samples, which is helpful for comprehensive evaluation of the quality of C. setosum. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. A mainstream monitoring system for respiratory CO2 concentration and gasflow.

    PubMed

    Yang, Jiachen; Chen, Bobo; Burk, Kyle; Wang, Haitao; Zhou, Jianxiong

    2016-08-01

    Continuous respiratory gas monitoring is an important tool for clinical monitoring. In particular, measurement of respiratory [Formula: see text] concentration and gasflow can reflect the status of a patient by providing parameters such as volume of carbon dioxide, end-tidal [Formula: see text] respiratory rate and alveolar deadspace. However, in the majority of previous work, [Formula: see text] concentration and gasflow have been studied separately. This study focuses on a mainstream system which simultaneously measures respiratory [Formula: see text] concentration and gasflow at the same location, allowing for volumetric capnography to be implemented. A non-dispersive infrared monitor is used to measure [Formula: see text] concentration and a differential pressure sensor is used to measure gasflow. In developing this new device, we designed a custom airway adapter which can be placed in line with the breathing circuit and accurately monitor relevant respiratory parameters. Because the airway adapter is used both for capnography and gasflow, our system reduces mechanical deadspace. The finite element method was used to design the airway adapter which can provide a strong differential pressure while reducing airway resistance. Statistical analysis using the coefficient of variation was performed to find the optimal driving voltage of the pressure transducer. Calibration between variations and flows was used to avoid pressure signal drift. We carried out targeted experiments using the proposed device and confirmed that the device can produce stable signals.

  6. Utilizing GCaMP transgenic mice to monitor endogenous Gq/11-coupled receptors

    PubMed Central

    Partridge, John G.

    2015-01-01

    The family of GCaMPs are engineered proteins that contain Ca2+ binding motifs within a circularly permutated variant of the Aequorea Victoria green fluorescent protein (cp-GFP). The rapidly advancing field of utilizing GCaMP reporter constructs represents a major step forward in our ability to monitor intracellular Ca2+ dynamics. With the use of these genetically encoded Ca2+ sensors, investigators have studied activation of endogenous Gq types of G protein-coupled receptors (GPCRs) and subsequent rises in intracellular calcium. Escalations in intracellular Ca2+ from GPCR activation can be faithfully monitored in space and time as an increase in fluorescent emission from these proteins. Further, transgenic mice are now commercially available that express GCaMPs in a Cre recombinase dependent fashion. These GCaMP reporter mice can be bred to distinct Cre recombinase driver mice to direct expression of this sensor in unique populations of cells. Concerning the central nervous system (CNS), sources of calcium influx, including those arising from Gq activation can be observed in targeted cell types like neurons or astrocytes. This powerful genetic method allows simultaneous monitoring of the activity of dozens of cells upon activation of endogenous Gq-coupled GPCRs. Therefore, in combination with pharmacological tools, this strategy of monitoring GPCR activation is amenable to analysis of orthosteric and allosteric ligands of Gq-coupled receptors in their endogenous environments. PMID:25805995

  7. Development of an On-animal Separation-based Sensor for Monitoring Drug Metabolism in Freely Roaming Sheep

    PubMed Central

    Scott, David E.; Willis, Sean D.; Gabbert, Seth; Johnson, Dave A.; Naylor, Erik; Janle, Elsa M.; Krichevsky, Janice E.; Lunte, Craig E.; Lunte, Susan M.

    2015-01-01

    The development of an on-animal separation-based sensor that can be employed for monitoring drug metabolism in a freely roaming sheep is described. The system consists of microdialysis sampling coupled directly to microchip electrophoresis with electrochemical detection (MD-ME-EC). Separations were accomplished using an all-glass chip with integrated platinum working and reference electrodes. Discrete samples from the microdialysis flow were introduced into the electrophoresis chip using a flow-gated injection approach. Electrochemical detection was accomplished in-channel using a two-electrode isolated potentiostat. Nitrite was separated by microchip electrophoresis using reverse polarity and a run buffer consisting of 50 mM phosphate at pH 7.4. The entire system was under telemetry control. The system was first tested with rats to monitor the production of nitrite following introduction of nitroglycerin into the subdermal tissue using a linear probe. The data acquired using the on-line MD-ME-EC system was compared to that obtained off-line analysis by liquid chromatography with electrochemical detection (LC-EC), using a second microdialysis probe implanted parallel to the first probe in the same animal. The MD-ME-EC device was then used on-animal to monitor the subdermal metabolism of nitroglycerin in sheep. The ultimate goal is to use this device to simultaneously monitor drug metabolism and behavior in a freely roaming animal. PMID:25697221

  8. Simultaneous monitoring of maternal and fetal heart rate variability during labor in relation with fetal gender.

    PubMed

    Gonçalves, Hernâni; Fernandes, Diana; Pinto, Paula; Ayres-de-Campos, Diogo; Bernardes, João

    2017-11-01

    Male gender is considered a risk factor for several adverse perinatal outcomes. Fetal gender effect on fetal heart rate (FHR) has been subject of several studies with contradictory results. The importance of maternal heart rate (MHR) monitoring during labor has also been investigated, but less is known about the effect of fetal gender on MHR. The aim of this study is to simultaneously assess maternal and FHR variability during labor in relation with fetal gender. Simultaneous MHR and FHR recordings were obtained from 44 singleton term pregnancies during the last 2 hr of labor (H 1, H 2 ). Heart rate tracings were analyzed using linear (time- and frequency-domain) and nonlinear indices. Both linear and nonlinear components were considered in assessing FHR and MHR interaction, including cross-sample entropy (cross-SampEn). Mothers carrying male fetuses (n = 22) had significantly higher values for linear indices related with MHR average and variability and sympatho-vagal balance, while the opposite occurred in the high-frequency component and most nonlinear indices. Significant differences in FHR were only observed in H 1 with higher entropy values in female fetuses. Assessing the differences between FHR and MHR, statistically significant differences were obtained in most nonlinear indices between genders. A significantly higher cross-SampEn was observed in mothers carrying female fetuses (n = 22), denoting lower synchrony or similarity between MHR and FHR. The variability of MHR and the synchrony/similarity between MHR and FHR vary with respect to fetal gender during labor. These findings suggest that fetal gender needs to be taken into account when simultaneously monitoring MHR and FHR. © 2017 Wiley Periodicals, Inc.

  9. A Review of Player Monitoring Approaches in Basketball: Current Trends and Future Directions.

    PubMed

    Fox, Jordan L; Scanlan, Aaron T; Stanton, Robert

    2017-07-01

    Fox, JL, Scanlan, AT, and Stanton, R. A review of player monitoring approaches in basketball: current trends and future directions. J Strength Cond Res 31(7): 2021-2029, 2017-Effective monitoring of players in team sports such as basketball requires an understanding of the external demands and internal responses, as they relate to training phases and competition. Monitoring of external demands and internal responses allows coaching staff to determine the dose-response associated with the imposed training load (TL), and subsequently, if players are adequately prepared for competition. This review discusses measures reported in the literature for monitoring the external demands and internal responses of basketball players during training and competition. The external demands of training and competition were primarily monitored using time-motion analysis, with limited use of microtechnology being reported. Internal responses during training were typically measured using hematological markers, heart rate, various TL models, and perceptual responses such as rating of perceived exertion (RPE). Heart rate was the most commonly reported indicator of internal responses during competition with limited reporting of hematological markers or RPE. These findings show a large discrepancy between the reporting of external and internal measures and training and competition demands. Microsensors, however, may be a practical and convenient method of player monitoring in basketball to overcome the limitations associated with current approaches while allowing for external demands and internal responses to be recorded simultaneously. The triaxial accelerometers of microsensors seem well suited for basketball and warrant validation to definitively determine their place in the monitoring of basketball players. Coaching staff should make use of this technology by tracking individual player responses across the annual plan and using real-time monitoring to minimize factors such as fatigue and injury risk.

  10. Atrial Fibrillation Detection During 24-Hour Ambulatory Blood Pressure Monitoring: Comparison With 24-Hour Electrocardiography.

    PubMed

    Kollias, Anastasios; Destounis, Antonios; Kalogeropoulos, Petros; Kyriakoulis, Konstantinos G; Ntineri, Angeliki; Stergiou, George S

    2018-07-01

    This study assessed the diagnostic accuracy of a novel 24-hour ambulatory blood pressure (ABP) monitor (Microlife WatchBP O3 Afib) with implemented algorithm for automated atrial fibrillation (AF) detection during each ABP measurement. One hundred subjects (mean age 70.6±8.2 [SD] years; men 53%; hypertensives 85%; 17 with permanent AF; 4 paroxysmal AF; and 79 non-AF) had simultaneous 24-hour ABP monitoring and 24-hour Holter monitoring. Among a total of 6410 valid ABP readings, 1091 (17%) were taken in ECG AF rhythm. In reading-to-reading ABP analysis, the sensitivity, specificity, and accuracy of ABP monitoring in detecting AF were 93%, 87%, and 88%, respectively. In non-AF subjects, 12.8% of the 24-hour ABP readings indicated false-positive AF, of whom 27% were taken during supraventricular premature beats. There was a strong association between the proportion of false-positive AF readings and that of supraventricular premature beats ( r =0.67; P <0.001). Receiver operating characteristic curve revealed that in paroxysmal AF and non-AF subjects, AF-positive readings at 26% during 24-hour ABP monitoring had 100%/85% sensitivity/specificity (area under the curve 0.91; P <0.01) for detecting paroxysmal AF. These findings suggest that in elderly hypertensives, a novel 24-hour ABP monitor with AF detector has high sensitivity and moderate specificity for AF screening during routine ABP monitoring. Thus, in elderly hypertensives, a 24-hour ABP recording with at least 26% of the readings suggesting AF indicates a high probability for AF diagnosis and should be regarded as an indication for performing 24-hour Holter monitoring. © 2018 American Heart Association, Inc.

  11. An Advanced Approach to Simultaneous Monitoring of Multiple Bacteria in Space

    NASA Technical Reports Server (NTRS)

    Eggers, M.

    1998-01-01

    The utility of a novel microarray-based microbial analyzer was demonstrated by the rapid detection, imaging, and identification of a mixture of microorganisms found in a waste water sample from the Lunar-Mars Life Support Test Project through the synergistic combination of: (1) judicious RNA probe selection via algorithms developed by University of Houston scientists; (2) tuned surface chemistries developed by Baylor College of Medicine scientists to facilitate hybridization of rRNA targets to DNA probes under very low salt conditions, thereby minimizing secondary structure; and (3) integration of the microarray printing and detection/imaging instrumentation by Genometrix to complete the quantitative analysis of microorganism mixtures.

  12. Development of an online SPE-UHPLC-MS/MS method for the multiresidue analysis of the 17 compounds from the EU "Watch list".

    PubMed

    Gusmaroli, Lucia; Insa, Sara; Petrovic, Mira

    2018-04-24

    During the last decades, the quality of aquatic ecosystems has been threatened by increasing levels of pollutions, caused by the discharge of man-made chemicals, both via accidental release of pollutants as well as a consequence of the constant outflow of inadequately treated wastewater effluents. For this reason, the European Union is updating its legislations with the aim of limiting the release of emerging contaminants. The Commission Implementing Decision (EU) 2015/495 published in March 2015 drafts a "Watch list" of compounds to be monitored Europe-wide. In this study, a methodology based on online solid-phase extraction (SPE) ultra-high-performance liquid chromatography coupled to a triple-quadrupole mass spectrometer (UHPLC-MS/MS) was developed for the simultaneous determination of the 17 compounds listed therein. The proposed method offers advantages over already available methods, such as versatility (all 17 compounds can be analyzed simultaneously), shorter time required for analysis, robustness, and sensitivity. The employment of online sample preparation minimized sample manipulation and reduced dramatically the sample volume needed and time required, dramatically the sample volume needed and time required, thus making the analysis fast and reliable. The method was successfully validated in surface water and influent and effluent wastewater. Limits of detection ranged from sub- to low-nanogram per liter levels, in compliance with the EU limits, with the only exception of EE2. Graphical abstract Schematic of the workflow for the analysis of the Watch list compounds.

  13. Using task analysis to understand the Data System Operations Team

    NASA Technical Reports Server (NTRS)

    Holder, Barbara E.

    1994-01-01

    The Data Systems Operations Team (DSOT) currently monitors the Multimission Ground Data System (MGDS) at JPL. The MGDS currently supports five spacecraft and within the next five years, it will support ten spacecraft simultaneously. The ground processing element of the MGDS consists of a distributed UNIX-based system of over 40 nodes and 100 processes. The MGDS system provides operators with little or no information about the system's end-to-end processing status or end-to-end configuration. The lack of system visibility has become a critical issue in the daily operation of the MGDS. A task analysis was conducted to determine what kinds of tools were needed to provide DSOT with useful status information and to prioritize the tool development. The analysis provided the formality and structure needed to get the right information exchange between development and operations. How even a small task analysis can improve developer-operator communications is described, and the challenges associated with conducting a task analysis in a real-time mission operations environment are examined.

  14. Comparison of diagnostic value using a small, single channel, P-wave centric sternal ECG monitoring patch with a standard 3-lead Holter system over 24 hours.

    PubMed

    Smith, Warren M; Riddell, Fiona; Madon, Morag; Gleva, Marye J

    2017-03-01

    To compare simultaneous recordings from an external patch system specifically designed to ensure better P-wave recordings and standard Holter monitor to determine diagnostic efficacy. Holter monitors are a mainstay of clinical practice, but are cumbersome to access and wear and P-wave signal quality is frequently inadequate. This study compared the diagnostic efficacy of the P-wave centric electrocardiogram (ECG) patch (Carnation Ambulatory Monitor) to standard 3-channel (leads V1, II, and V5) Holter monitor (Northeast Monitoring, Maynard, MA). Patients were referred to a hospital Holter clinic for standard clinical indications. Each patient wore both devices simultaneously and served as their own control. Holter and Patch reports were read in a blinded fashion by experienced electrophysiologists unaware of the findings in the other corresponding ECG recording. All patients, technicians, and physicians completed a questionnaire on comfort and ease of use, and potential complications. In all 50 patients, the P-wave centric patch recording system identified rhythms in 23 patients (46%) that altered management, compared to 6 Holter patients (12%), P<.001. The patch ECG intervals PR, QRS and QT correlated well with the Holter ECG intervals having correlation coefficients of 0.93, 0.86, and 0.94, respectively. Finally, 48 patients (96%) preferred wearing the patch monitor. A single-channel ambulatory patch ECG monitor, designed specifically to ensure that the P-wave component of the ECG be visible, resulted in a significantly improved rhythm diagnosis and avoided inaccurate diagnoses made by the standard 3-channel Holter monitor. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Dual-Color Bioluminescence Imaging for Simultaneous Monitoring of the Intestinal Persistence of Lactobacillus plantarum and Lactococcus lactis in Living Mice

    PubMed Central

    Poiret, Sabine; Dennin, Véronique; Boutillier, Denise; Lacorre, Delphine Armelle; Foligné, Benoit; Pot, Bruno

    2015-01-01

    Lactic acid bacteria are found in the gastrointestinal tract of mammals and have received tremendous attention due to their health-promoting properties. We report the development of two dual-color luciferase-producing Lactobacillus (Lb.) plantarum and Lactococcus (Lc.) lactis strains for noninvasive simultaneous tracking in the mouse gastrointestinal tract. We previously described the functional expression of the red luciferase mutant (CBRluc) from Pyrophorus plagiophthalamus in Lb. plantarum NCIMB8826 and Lc. lactis MG1363 (C. Daniel, S. Poiret, V. Dennin, D. Boutillier, and B. Pot, Appl Environ Microbiol 79:1086–1094, 2013, http://dx.doi.org/10.1128/AEM.03221-12). In this study, we determined that CBRluc is a better-performing luciferase for in vivo localization of both lactic acid bacteria after oral administration than the green click beetle luciferase mutant construct developed in this study. We further established the possibility to simultaneously detect red- and green-emitting lactic acid bacteria by dual-wavelength bioluminescence imaging in combination with spectral unmixing. The difference in spectra of light emission by the red and green click beetle luciferase mutants and dual bioluminescence detection allowed in vitro and in vivo quantification of the red and green emitted signals; thus, it allowed us to monitor the dynamics and fate of the two bacterial populations simultaneously. Persistence and viability of both strains simultaneously administered to mice in different ratios was studied in vivo in anesthetized mice and ex vivo in mouse feces. The application of dual-luciferase-labeled bacteria has considerable potential to simultaneously study the interactions and potential competitions of different targeted bacteria and their hosts. PMID:26025906

  16. Non-invasive monitoring of spreading depression.

    PubMed

    Bastany, Zoya J R; Askari, Shahbaz; Dumont, Guy A; Speckmann, Erwin-Josef; Gorji, Ali

    2016-10-01

    Spreading depression (SD), a slow propagating depolarization wave, plays an important role in pathophysiology of different neurological disorders. Yet, research into SD-related disorders has been hampered by the lack of non-invasive recording techniques of SD. Here we compared the manifestations of SD in continuous non-invasive electroencephalogram (EEG) recordings to invasive electrocorticographic (ECoG) recordings in order to obtain further insights into generator structures and electrogenic mechanisms of surface recording of SD. SD was induced by KCl application and simultaneous SD recordings were performed by scalp EEG as well as ECoG electrodes of somatosensory neocortex of rats using a novel homemade EEG amplifier, AgCl recording electrodes, and high chloride conductive gel. Different methods were used to analyze the data; including the spectrogram, bi-spectrogram, pattern distribution, relative spectrum power, and multivariable Gaussian fit analysis. The negative direct current (DC) shifts recorded by scalp electrodes exhibited a high homogeneity to those recorded by ECoG electrodes. Furthermore, this novel method of recording and analysis was able to separate SD recorded by scalp electrodes from non-neuronal DC shifts induced by other potential generators, such as the skin, muscles, arteries, dura, etc. These data suggest a novel application for continuous non-invasive monitoring of DC potential changes, such as SD. Non-invasive monitoring of SD would allow early intervention and improve outcome in SD-related neurological disorders. Copyright © 2016 IBRO. All rights reserved.

  17. Pharmacokinetics-on-a-Chip Using Label-Free SERS Technique for Programmable Dual-Drug Analysis.

    PubMed

    Fei, Jiayuan; Wu, Lei; Zhang, Yizhi; Zong, Shenfei; Wang, Zhuyuan; Cui, Yiping

    2017-06-23

    Synergistic effects of dual or multiple drugs have attracted great attention in medical fields, especially in cancer therapies. We provide a programmable microfluidic platform for pharmacokinetic detection of multiple drugs in multiple cells. The well-designed microfluidic platform includes two 2 × 3 microarrays of cell chambers, two gradient generators, and several pneumatic valves. Through the combined use of valves and gradient generators, each chamber can be controlled to infuse different kinds of living cells and drugs with specific concentrations as needed. In our experiments, 6-mercaptopurine (6MP) and methimazole (MMI) were chosen as two drug models and their pharmacokinetic parameters in different living cells were monitored through intracellular SERS spectra, which reflected the molecular structure of these drugs. The dynamic change of SERS fingerprints from 6MP and MMI molecules were recorded during drug metabolism in living cells. The results indicated that both 6MP and MMI molecules were diffused into the cells within 4 min and excreted out after 36 h. Moreover, the intracellular distribution of these drugs was monitored through SERS mapping. Thus, our microfluidic platform simultaneously accomplishes the functions to monitor pharmacokinetic action, distribution, and fingerprint of multiple drugs in multiple cells. Owing to its real-time, rapid-speed, high-precision, and programmable capability of multiple-drug and multicell analysis, such a microfluidic platform has great potential in drug design and development.

  18. Multicomponent kinetic spectrophotometric determination of pefloxacin and norfloxacin in pharmaceutical preparations and human plasma samples with the aid of chemometrics

    NASA Astrophysics Data System (ADS)

    Ni, Yongnian; Wang, Yong; Kokot, Serge

    2008-10-01

    A spectrophotometric method for the simultaneous determination of the important pharmaceuticals, pefloxacin and its structurally similar metabolite, norfloxacin, is described for the first time. The analysis is based on the monitoring of a kinetic spectrophotometric reaction of the two analytes with potassium permanganate as the oxidant. The measurement of the reaction process followed the absorbance decrease of potassium permanganate at 526 nm, and the accompanying increase of the product, potassium manganate, at 608 nm. It was essential to use multivariate calibrations to overcome severe spectral overlaps and similarities in reaction kinetics. Calibration curves for the individual analytes showed linear relationships over the concentration ranges of 1.0-11.5 mg L -1 at 526 and 608 nm for pefloxacin, and 0.15-1.8 mg L -1 at 526 and 608 nm for norfloxacin. Various multivariate calibration models were applied, at the two analytical wavelengths, for the simultaneous prediction of the two analytes including classical least squares (CLS), principal component regression (PCR), partial least squares (PLS), radial basis function-artificial neural network (RBF-ANN) and principal component-radial basis function-artificial neural network (PC-RBF-ANN). PLS and PC-RBF-ANN calibrations with the data collected at 526 nm, were the preferred methods—%RPE T ˜ 5, and LODs for pefloxacin and norfloxacin of 0.36 and 0.06 mg L -1, respectively. Then, the proposed method was applied successfully for the simultaneous determination of pefloxacin and norfloxacin present in pharmaceutical and human plasma samples. The results compared well with those from the alternative analysis by HPLC.

  19. A multi-phenotypic imaging screen to identify bacterial effectors by exogenous expression in a HeLa cell line.

    PubMed

    Collins, Adam; Huett, Alan

    2018-05-15

    We present a high-content screen (HCS) for the simultaneous analysis of multiple phenotypes in HeLa cells expressing an autophagy reporter (mcherry-LC3) and one of 224 GFP-fused proteins from the Crohn's Disease (CD)-associated bacterium, Adherent Invasive E. coli (AIEC) strain LF82. Using automated confocal microscopy and image analysis (CellProfiler), we localised GFP fusions within cells, and monitored their effects upon autophagy (an important innate cellular defence mechanism), cellular and nuclear morphology, and the actin cytoskeleton. This data will provide an atlas for the localisation of 224 AIEC proteins within human cells, as well as a dataset to analyse their effects upon many aspects of host cell morphology. We also describe an open-source, automated, image-analysis workflow to identify bacterial effectors and their roles via the perturbations induced in reporter cell lines when candidate effectors are exogenously expressed.

  20. Protein mass analysis of histones.

    PubMed

    Galasinski, Scott C; Resing, Katheryn A; Ahn, Natalie G

    2003-09-01

    Posttranslational modification of chromatin-associated proteins, including histones and high-mobility-group (HMG) proteins, provides an important mechanism to control gene expression, genome integrity, and epigenetic inheritance. Protein mass analysis provides a rapid and unbiased approach to monitor multiple chemical modifications on individual molecules. This review describes methods for acid extraction of histones and HMG proteins, followed by separation by reverse-phase chromatography coupled to electrospray ionization mass spectrometry (LC/ESI-MS). Posttranslational modifications are detected by analysis of full-length protein masses. Confirmation of protein identity and modification state is obtained through enzymatic digestion and peptide sequencing by MS/MS. For differentially modified forms of each protein, the measured intensities are semiquantitative and allow determination of relative abundance and stoichiometry. The method simultaneously detects covalent modifications on multiple proteins and provides a facile assay for comparing chromatin modification states between different cell types and/or cellular responses.

  1. Method for using acoustic sounder categories to determine atmospheric stability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schubert, J.F.

    1979-01-01

    Capabilities of the diffusion meteorologist have been expanded by the acoustic sounder, an economical tool for monitoring in real time the height of the mixed layer. The acoustic sounder continuously measures the rate of change in the height of the mixed layer which is an important parameter in calculating the transport and diffusion of radioactive and nonradioactive air pollutants. Continuous record of convective cells, gravity waves, inversions, and frontal systems permit analysis of the synoptic (analysis of stability in terms of simultaneous weather information) and complex (analysis of the stability of a single place by the relative frequencies of variousmore » stability types or groups of such types) stabilities of the local area. Sounder data obtained at the Savannah River Plant was compared on an hourly basis to data obtained at the WJBF-TV tower located approximately 20 km northwest of the acoustic sounder site.« less

  2. Incorporating engine health monitoring capability into the SSME Block II controller

    NASA Astrophysics Data System (ADS)

    Clarke, James W.; Copa, Roderick J.

    An account is given of the architecture of the SSME's Block II controller's architecture, its incorporation of smart input electronics (SIE), and the potential benefits of this technology in SSME health-monitoring capabilities. SIE allows the Block II controller to conduct its control functions while simultaneously furnishing the computational capabilities and sensor input interface for any newly defined health-monitoring functions. It is expected that the SIE technology may be directly transferred to any follow-on engine design.

  3. A Comprehensive Evaluation of a Two-Channel Portable Monitor to “Rule in” Obstructive Sleep Apnea

    PubMed Central

    Ward, Kim L.; McArdle, Nigel; James, Alan; Bremner, Alexandra P.; Simpson, Laila; Cooper, Matthew N.; Palmer, Lyle J.; Fedson, Annette C.; Mukherjee, Sutapa; Hillman, David R.

    2015-01-01

    Study Objectives: We hypothesized that a dual-channel portable monitor (PM) device could accurately identify patients who have a high pretest probability of obstructive sleep apnea (OSA), and we evaluated factors that may contribute to variability between PM and polysomnography (PSG) results. Methods: Consecutive clinic patients (N = 104) with possible OSA completed a home PM study, a PM study simultaneous with laboratory PSG, and a second home PM study. Uniform data analysis methods were applied to both PM and PSG data. Primary outcomes of interest were the positive likelihood ratio (LR+) and sensitivity of the PM device to “rule-in” OSA, defined as an apnea-hypopnea index (AHI) ≥ 5 events/h on PSG. Effects of different test environment and study nights, and order of study and analysis methods (manual compared to automated) on PM diagnostic accuracy were assessed. Results: The PM has adequate LR+ (4.8), sensitivity (80%), and specificity (83%) for detecting OSA in the unattended home setting when benchmarked against laboratory PSG, with better LR+ (> 5) and specificity (100%) and unchanged sensitivity (80%) in the simultaneous laboratory comparison. There were no significant night-night (all p > 0.10) or study order effects (home or laboratory first, p = 0.08) on AHI measures. Manual PM data review improved case finding accuracy, although this was not statistically significant (all p > 0.07). Misclassification was more frequent where OSA was mild. Conclusions: Overall performance of the PM device is consistent with current recommended criteria for an “acceptable” device to confidently “rule-in” OSA (AHI ≥ 5 events/h) in a high pretest probability clinic population. Our data support the utility of simple two-channel diagnostic devices to confirm the diagnosis of OSA in the home environment. Commentary: A commentary on this article appears in this issue on page 411. Citation: Ward KL, McArdle N, James A, Bremner AP, Simpson L, Cooper MN, Palmer LJ, Fedson AC, Mukherjee S, Hillman DR. A comprehensive evaluation of a two-channel portable monitor to “rule in” obstructive sleep apnea. J Clin Sleep Med 2015;11(4):433–444. PMID:25580606

  4. A low cost mid-infrared sensor for on line contamination monitoring of lubricating oils in marine engines

    NASA Astrophysics Data System (ADS)

    Ben Mohammadi, L.; Kullmann, F.; Holzki, M.; Sigloch, S.; Klotzbuecher, T.; Spiesen, J.; Tommingas, T.; Weismann, P.; Kimber, G.

    2010-04-01

    The chemical and physical condition of oils in marine engines must be monitored to ensure optimum performance of the engine and to avoid damage by degraded oil not adequately lubricating the engine. Routine monitoring requires expensive laboratory testing and highly skilled analysts. This work describes the adaptation and implementation of a mid infrared (MIR) sensor module for continued oil condition monitoring in two-stroke and four-stroke diesel engines. The developed sensor module will help to reduce costs in oil analysis by eliminating the need to collect and send samples to a laboratory for analysis. The online MIR-Sensor module measures the contamination of oil with water, soot, as well as the degradation indicated by the TBN (Total Base Number) value. For the analysis of water, TBN, and soot in marine engine oils, four spectral regions of interest have been identified. The optical absorption in these bands correlating with the contaminations is measured simultaneously by using a four-field thermopile detector, combined with appropriate bandpass filters. Recording of the MIR-absorption was performed in a transmission mode using a flow-through cell with appropriate path length. Since in this case no spectrometer is required, the sensor including the light source, the flowthrough- cell, and the detector can be realised at low cost and in a very compact manner. The optical configuration of the sensor with minimal component number and signal intensity optimisation at the four-field detector was implemented by using non-sequential ray tracing simulation. The used calibration model was robust enough to predict accurately the value for soot, water, and TBN concentration for two-stroke and four-stroke engine oils. The sensor device is designed for direct installation on the host engine or machine and, therefore, becoming an integral part of the lubrication system. It can also be used as a portable stand-alone system for machine fluid analysis in the field.

  5. Multiple reaction monitoring assay based on conventional liquid chromatography and electrospray ionization for simultaneous monitoring of multiple cerebrospinal fluid biomarker candidates for Alzheimer's disease

    PubMed Central

    Choi1, Yong Seok; Lee, Kelvin H.

    2016-01-01

    Alzheimer's disease (AD) is the most common type of dementia, but early and accurate diagnosis remains challenging. Previously, a panel of cerebrospinal fluid (CSF) biomarker candidates distinguishing AD and non-AD CSF accurately (> 90%) was reported. Furthermore, a multiple reaction monitoring (MRM) assay based on nano liquid chromatography tandem mass spectrometry (nLC-MS/MS) was developed to help validate putative AD CSF biomarker candidates including proteins from the panel. Despite the good performance of the MRM assay, wide acceptance may be challenging because of limited availability of nLC-MS/MS systems laboratories. Thus, here, a new MRM assay based on conventional LC-MS/MS is presented. This method monitors 16 peptides representing 16 (of 23) biomarker candidates that belonged to the previous AD CSF panel. A 30-times more concentrated sample than the sample used for the previous study was loaded onto a high capacity trap column, and all 16 MRM transitions showed good linearity (average R2 = 0.966), intra-day reproducibility (average coefficient of variance (CV) = 4.78%), and inter-day reproducibility (average CV = 9.85%). The present method has several advantages such as a shorter analysis time, no possibility of target variability, and no need for an internal standard. PMID:26404792

  6. A Low-Power and Portable Biomedical Device for Respiratory Monitoring with a Stable Power Source

    PubMed Central

    Yang, Jiachen; Chen, Bobo; Zhou, Jianxiong; Lv, Zhihan

    2015-01-01

    Continuous respiratory monitoring is an important tool for clinical monitoring. Associated with the development of biomedical technology, it has become more and more important, especially in the measuring of gas flow and CO2 concentration, which can reflect the status of the patient. In this paper, a new type of biomedical device is presented, which uses low-power sensors with a piezoresistive silicon differential pressure sensor to measure gas flow and with a pyroelectric sensor to measure CO2 concentration simultaneously. For the portability of the biomedical device, the sensors and low-power measurement circuits are integrated together, and the airway tube also needs to be miniaturized. Circuits are designed to ensure the stability of the power source and to filter out the existing noise. Modulation technology is used to eliminate the fluctuations at the trough of the waveform of the CO2 concentration signal. Statistical analysis with the coefficient of variation was performed to find out the optimal driving voltage of the pressure transducer. Through targeted experiments, the biomedical device showed a high accuracy, with a measuring precision of 0.23 mmHg, and it worked continuously and stably, thus realizing the real-time monitoring of the status of patients. PMID:26270665

  7. Real-time electrochemical monitoring of isothermal helicase-dependent amplification of nucleic acids.

    PubMed

    Kivlehan, Francine; Mavré, François; Talini, Luc; Limoges, Benoît; Marchal, Damien

    2011-09-21

    We described an electrochemical method to monitor in real-time the isothermal helicase-dependent amplification of nucleic acids. The principle of detection is simple and well-adapted to the development of portable, easy-to-use and inexpensive nucleic acids detection technologies. It consists of monitoring a decrease in the electrochemical current response of a reporter DNA intercalating redox probe during the isothermal DNA amplification. The method offers the possibility to quantitatively analyze target nucleic acids in less than one hour at a single constant temperature, and to perform at the end of the isothermal amplification a DNA melt curve analysis for differentiating between specific and non-specific amplifications. To illustrate the potentialities of this approach for the development of a simple, robust and low-cost instrument with high throughput capability, the method was validated with an electrochemical system capable of monitoring up to 48 real-time isothermal HDA reactions simultaneously in a disposable microplate consisting of 48-electrochemical microwells. Results obtained with this approach are comparable to that obtained with a well-established but more sophisticated and expensive fluorescence-based method. This makes for a promising alternative detection method not only for real-time isothermal helicase-dependent amplification of nucleic acid, but also for other isothermal DNA amplification strategies.

  8. Multiple reaction monitoring assay based on conventional liquid chromatography and electrospray ionization for simultaneous monitoring of multiple cerebrospinal fluid biomarker candidates for Alzheimer's disease.

    PubMed

    Choi, Yong Seok; Lee, Kelvin H

    2016-03-01

    Alzheimer's disease (AD) is the most common type of dementia, but early and accurate diagnosis remains challenging. Previously, a panel of cerebrospinal fluid (CSF) biomarker candidates distinguishing AD and non-AD CSF accurately (>90 %) was reported. Furthermore, a multiple reaction monitoring (MRM) assay based on nano liquid chromatography tandem mass spectrometry (nLC-MS/MS) was developed to help validate putative AD CSF biomarker candidates including proteins from the panel. Despite the good performance of the MRM assay, wide acceptance may be challenging because of limited availability of nLC-MS/MS systems in laboratories. Thus, here, a new MRM assay based on conventional LC-MS/MS is presented. This method monitors 16 peptides representing 16 (of 23) biomarker candidates that belonged to the previous AD CSF panel. A 30-times more concentrated sample than the sample used for the previous study was loaded onto a high capacity trap column, and all 16 MRM transitions showed good linearity (average R(2) = 0.966), intra-day reproducibility (average coefficient of variance (CV) = 4.78 %), and inter-day reproducibility (average CV = 9.85 %). The present method has several advantages such as a shorter analysis time, no possibility of target variability, and no need for an internal standard.

  9. Instructor Support Feature Guidelines. Volume 2.

    DTIC Science & Technology

    1986-05-01

    starts his final approach, the display formats change to provide graphic depictions of glideslope, lineup and airspeed parameters, and indications of...and evaluate several facets of student performance simultaneously . It may also provide objective, standardized performance measurement of the student’s...procedures monitoring feature shall provide the instructor cation with a method of monitoring the sequential mission training activities of a student. The

  10. Water Quality Monitoring: An Environmental Studies Unit for Biology 20/30. Teacher's Guide.

    ERIC Educational Resources Information Center

    Alberta Environment, Edmonton. Environmental Education Resources Branch.

    The objective of this environmental studies unit is to establish a water quality monitoring project for high school students in Alberta while simultaneously providing a unit which meets the objectives of the Biology 20 program (and which may also be used in Biology 10 and 30). Through this project, students assist in the collection,…

  11. Water Quality Monitoring: An Environmental Studies Unit for Biology 20/30. Student Manual.

    ERIC Educational Resources Information Center

    Alberta Environment, Edmonton. Environmental Education Resources Branch.

    The objective of this environmental studies unit is to establish a water quality monitoring project for high school students in Alberta while simultaneously providing a unit which meets the objectives of the Biology 20 program (and which may also be used in Biology 10 and 30). Through this project, students assist in the collection,…

  12. Acid Gastroesophageal Reflux Disease and Apparent Life-Threatening Events: Simultaneous pH-metry and Cardiorespiratory Monitoring.

    PubMed

    Macchini, Francesco; Morandi, Anna; Cognizzoli, Paola; Farris, Giorgio; Gentilino, Valerio; Zanini, Andrea; Leva, Ernesto

    2017-02-01

    To investigate the prevalence and the characteristics of gastroesophageal reflux disease (GERD) in infants with apparent life threatening events (ALTE). Infants with at least one episode of ALTE in absence of predisposing factors were included. All infants underwent a cardiorespiratory recording with simultaneous 24-hour pH-monitoring. Patients were divided into 3 groups according to the severity of GERD: A. Reflux Index (RI) <3%, B. RI = 3-7%, C. RI >7%. Monthly evaluations were performed and the anti-reflux therapy was maintained till normalization of monitoring and clinic. 41 infants were enrolled. GERD was found in 80% of patients (moderate in 54%, severe in 27%). A normalization of the cardiorespiratory tracks was recorded on average after 1 month for group A, 7 months for the group B and 9.5 months for group C. A significant difference was registered between group A and both group B and C (P < 0.0001), as well as between the group B and C (P < 0.05). GERD influences significantly the time of normalization of the cardiorespiratory monitoring in infants with ALTE. GERD diagnosis and treatment are mandatory in these patients. Copyright © 2016. Published by Elsevier B.V.

  13. On the importance of simultaneous infrared/fiber-optic temperature monitoring in the microwave-assisted synthesis of ionic liquids.

    PubMed

    Obermayer, David; Kappe, C Oliver

    2010-01-07

    The temperature profiles obtained from both an external infrared and internal fiber-optic sensor were compared for heating and synthesizing the ionic liquid 1-butyl-3-methylimidazolium bromide (bmimBr) under microwave conditions. Utilizing a single-mode microwave reactor that allows simultaneous infrared/fiber-optic temperature measurements, significant differences between the two methods of temperature monitoring were revealed. Due to the strong microwave absorptivity of ionic liquids and the delay experienced in monitoring temperature on the outer surface of a heavy-walled glass vial, external infrared temperature sensors can not be used to accurately control the temperature in the heating of ionic liquids under microwave conditions. The use of internal fiber-optic probes allows the monitoring and control of the heating behavior in a much better way. In order to prevent the strong exotherm in the synthesis of bmimBr under microwave conditions the use of a reaction vessel made out of silicon carbide is the method of choice. Because of the high thermal conductivity and effusivity of silicon carbide, the heat generated during the ionic liquid formation is efficiently exchanged with the comparatively cool air in the microwave cavity via the silicon carbide ceramic.

  14. Artifactual ECG changes induced by electrocautery in a patient with coronary artery disease.

    PubMed

    Naik, B Naveen; Luthra, Ankur; Dwivedi, Ashish; Jafra, Anudeep

    Continuous monitoring of 5-lead electrocardiogram is a basic standard of care (included under standard ASA monitor) in the operating room and electrocautery interference is a common phenomenon. Clinical signs, along with monitored waveforms from other simultaneously monitored parameters may provide us clues to differentiate artifacts from true changes on the electrocardiogram. An improved understanding of the artifacts generated by electrocautery and their identifying characteristics is important to avoid misinterpretation, misdiagnosis, and hence mismanagement. This case report highlights the artifacts in electrocardiogram induced by electrocautery. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Simultaneous monitoring of glucose and uric acid on a single test strip with dual channels.

    PubMed

    Guo, Jinhong; Ma, Xing

    2017-08-15

    The conventional test strip has usually only one electrochemical reaction channel, which requires two times figure punctures for the self-management of patients suffering from both diabetes and gout. Considering the large number of such patients and for the sake of reducing their pains, we report an enzymatic test strip which can simultaneously monitor glucose and uric acid (UA) with only one fingertip blood droplet. The proposed test strip is composed of dual channels. The glucose in blood is detected in the 1st channel above on the substrate and the UA is characterized in the 2nd channel located at the bottom of the substrate. The proposed design intensively matches the requirement of those patients simultaneously suffering from diabetes and gout. We carried out comparative investigations on the proposed test strip and clinical biochemical analyser, which indicates a good agreement and proved the reliability and accuracy of the proposed test strip, as promising solution for the fast growth of family health management market. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Simultaneous application of two independent EIT devices for real-time multi-plane imaging.

    PubMed

    Schullcke, B; Krueger-Ziolek, S; Gong, B; Mueller-Lisse, U; Moeller, K

    2016-09-01

    Diagnosis and treatment of many lung diseases like cystic fibrosis (CF) or chronic obstructive pulmonary disease (COPD) could benefit from 3D ventilation information. Applying two EIT systems concurrently is a simple approach without specialized hardware that allows monitoring of regional changes of ventilation distribution inside the thorax at different planes with the high temporal resolution much valued in common single plane EIT. Effects of two simultaneously operated EIT devices on one subject were investigated to monitor rapid processes inside the thorax with a multi-plane approach. Results obtained by simulations with a virtual phantom and measurements with a phantom tank reveal that the distance of electrode planes has an important influence on the signal quality. Band-pass filters adapted according to the distance of the planes, can be used to reduce the crosstalk of the concurrent EIT systems. Besides simulations and phantom tank experiments measurements were also taken from a lung healthy volunteer to demonstrate the operation under realistic conditions. Reconstructed images indicate that it is possible to simultaneously visualize regional ventilation at different planes if settings of the EIT devices are chosen appropriately.

  17. Plasma process control with optical emission spectroscopy

    NASA Astrophysics Data System (ADS)

    Ward, P. P.

    Plasma processes for cleaning, etching and desmear of electronic components and printed wiring boards (PWB) are difficult to predict and control. Non-uniformity of most plasma processes and sensitivity to environmental changes make it difficult to maintain process stability from day to day. To assure plasma process performance, weight loss coupons or post-plasma destructive testing must be used. The problem with these techniques is that they are not real-time methods and do not allow for immediate diagnosis and process correction. These methods often require scrapping some fraction of a batch to insure the integrity of the rest. Since these methods verify a successful cycle with post-plasma diagnostics, poor test results often determine that a batch is substandard and the resulting parts unusable. Both of these methods are a costly part of the overall fabrication cost. A more efficient method of testing would allow for constant monitoring of plasma conditions and process control. Process failures should be detected before the parts being treated. are damaged. Real time monitoring would allow for instantaneous corrections. Multiple site monitoring would allow for process mapping within one system or simultaneous monitoring of multiple systems. Optical emission spectroscopy conducted external to the plasma apparatus would allow for this sort of multifunctional analysis without perturbing the glow discharge. In this paper, optical emission spectroscopy for non-intrusive, in situ process control will be explored. A discussion of this technique as it applies towards process control, failure analysis and endpoint determination will be conducted. Methods for identifying process failures, progress and end of etch back and desmear processes will be discussed.

  18. Method and system for monitoring and displaying engine performance parameters

    NASA Technical Reports Server (NTRS)

    Abbott, Terence S. (Inventor); Person, Lee H., Jr. (Inventor)

    1988-01-01

    The invention is believed a major improvement that will have a broad application in governmental and commercial aviation. It provides a dynamic method and system for monitoring and simultaneously displaying in easily scanned form the available, predicted, and actual thrust of a jet aircraft engine under actual operating conditions. The available and predicted thrusts are based on the performance of a functional model of the aircraft engine under the same operating conditions. Other critical performance parameters of the aircraft engine and functional model are generated and compared, the differences in value being simultaneously displayed in conjunction with the displayed thrust values. Thus, the displayed information permits the pilot to make power adjustments directly while keeping him aware of total performance at a glance of a single display panel.

  19. Simultaneous measurements of absorption spectrum and refractive index in a microfluidic system.

    PubMed

    Helseth, Lars Egil

    2012-02-13

    The characterization of dyes in various solvents requires determination of the absorption spectrum of the dye as well as the refractive index of the solvent. Typically, the refractive index of the solvent and the absorption spectrum of the solute are measured using separate experimental setups where significant liquid volumes are required. In this work the first optical measurement system that is able to do simultaneous measurements of the refractive index of the solvent and the spectral properties of the solute in a microscopic volume is presented. The laser dye Rhodamine 6G in glycerol is investigated, and the refractive index of the solution is monitored using the interference pattern of the light scattered off the channel, while its spectral properties is found by monitoring reflected light from the channel.

  20. Seismic Reservoir Characterization for Assessment of CO2 EOR at the Mississippian Reservoir in South-Central Kansas

    NASA Astrophysics Data System (ADS)

    Tsoflias, G. P.; Graham, B.; Haga, L.; Watney, L.

    2017-12-01

    The Mississippian in Kansas and Oklahoma is a highly heterogeneous, fractured, oil producing reservoir with thickness typically below seismic resolution. At Wellington field in south-central Kansas CO2 was injected in the Mississippian reservoir for enhanced oil recovery. This study examines the utility of active source surface seismic for characterization of Mississippian reservoir properties and monitoring CO2. Analysis of post-stack 3D seismic data showed the expected response of a gradational transition (ramp velocity) where thicker reservoir units corresponded with lower reflection amplitudes, lower frequency and a 90o phase change. Reflection amplitude could be correlated to reservoir thickness. Pre-stack gather analysis showed that porosity zones of the Mississippian reservoir exhibit characteristic AVO response. Simultaneous AVO inversion estimated P- and S-Impedances, which along with formation porosity logs and post-stack seismic data attributes were incorporated in multi-attribute linear-regression analysis and predicted reservoir porosity with an overall correlation of 0.90 to well data. The 3D survey gather azimuthal anisotropy analysis (AVAZ) provided information on the fault and fracture network and showed good agreement to the regional stress field and well data. Mississippian reservoir porosity and fracture predictions agreed well with the observed mobility of the CO2 in monitoring wells. Fluid substitution modeling predicted acoustic impedance reduction in the Mississippian carbonate reservoir introduced by the presence of CO2. Future work includes the assessment of time-lapse seismic, acquired after the injection of CO2. This work demonstrates that advanced seismic interpretation methods can be used successfully for characterization of the Mississippian reservoir and monitoring of CO2.

  1. Validation of a Rapid and Sensitive UPLC-MS-MS Method Coupled with Protein Precipitation for the Simultaneous Determination of Seven Pyrethroids in 100 µL of Rat Plasma by Using Ammonium Adduct as Precursor Ion.

    PubMed

    Singh, Sheelendra Pratap; Dwivedi, Nistha; Raju, Kanumuri Siva Rama; Taneja, Isha; Wahajuddin, Mohammad

    2016-04-01

    United States Environmental Protection Agency has recommended estimating pyrethroids' risk using cumulative exposure. For cumulative risk assessment, it would be useful to have a bioanalytical method for quantification of one or several pyrethroids simultaneously in a small sample volume to support toxicokinetic studies. Therefore, in the present study, a simple, sensitive and high-throughput ultraperformance liquid chromatography-tandem mass spectrometry method was developed and validated for simultaneous analysis of seven pyrethroids (fenvalerate, fenpropathrin, bifenthrin, lambda-cyhalothrin, cyfluthrin, cypermethrin and deltamethrin) in 100 µL of rat plasma. A simple single-step protein precipitation method was used for the extraction of target compounds. The total chromatographic run time of the method was 5 min. The chromatographic system used a Supelco C18 column and isocratic elution with a mobile phase consisting of methanol and 5 mM ammonium formate in the ratio of 90 : 10 (v/v). Mass spectrometer (API 4000) was operated in multiple reaction monitoring positive-ion mode using the electrospray ionization technique. The calibration curves were linear in the range of 7.8-2,000 ng/mL with correlation coefficients of ≥ 0.99. All validation parameters such as precision, accuracy, recovery, matrix effect and stability met the acceptance criteria according to the regulatory guidelines. The method was successfully applied to the toxicokinetic study of cypermethrin in rats. To the best of our knowledge, this is the first LC-MS-MS method for the simultaneous analysis of pyrethroids in rat plasma. This validated method with minimal modification can also be utilized for forensic and clinical toxicological applications due to its simplicity, sensitivity and rapidity. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Assessment of regional ventilation distribution: comparison of vibration response imaging (VRI) with electrical impedance tomography (EIT).

    PubMed

    Shi, Chang; Boehme, Stefan; Bentley, Alexander H; Hartmann, Erik K; Klein, Klaus U; Bodenstein, Marc; Baumgardner, James E; David, Matthias; Ullrich, Roman; Markstaller, Klaus

    2014-01-01

    Vibration response imaging (VRI) is a bedside technology to monitor ventilation by detecting lung sound vibrations. It is currently unknown whether VRI is able to accurately monitor the local distribution of ventilation within the lungs. We therefore compared VRI to electrical impedance tomography (EIT), an established technique used for the assessment of regional ventilation. Simultaneous EIT and VRI measurements were performed in the healthy and injured lungs (ALI; induced by saline lavage) at different PEEP levels (0, 5, 10, 15 mbar) in nine piglets. Vibration energy amplitude (VEA) by VRI, and amplitudes of relative impedance changes (rel.ΔZ) by EIT, were evaluated in seven regions of interest (ROIs). To assess the distribution of tidal volume (VT) by VRI and EIT, absolute values were normalized to the VT obtained by simultaneous spirometry measurements. Redistribution of ventilation by ALI and PEEP was detected by VRI and EIT. The linear correlation between pooled VT by VEA and rel.ΔZ was R(2) = 0.96. Bland-Altman analysis showed a bias of -1.07±24.71 ml and limits of agreement of -49.05 to +47.36 ml. Within the different ROIs, correlations of VT-distribution by EIT and VRI ranged between R(2) values of 0.29 and 0.96. ALI and PEEP did not alter the agreement of VT between VRI and EIT. Measurements of regional ventilation distribution by VRI are comparable to those obtained by EIT.

  3. Rapid and Simultaneous Prediction of Eight Diesel Quality Parameters through ATR-FTIR Analysis.

    PubMed

    Nespeca, Maurilio Gustavo; Hatanaka, Rafael Rodrigues; Flumignan, Danilo Luiz; de Oliveira, José Eduardo

    2018-01-01

    Quality assessment of diesel fuel is highly necessary for society, but the costs and time spent are very high while using standard methods. Therefore, this study aimed to develop an analytical method capable of simultaneously determining eight diesel quality parameters (density; flash point; total sulfur content; distillation temperatures at 10% (T10), 50% (T50), and 85% (T85) recovery; cetane index; and biodiesel content) through attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy and the multivariate regression method, partial least square (PLS). For this purpose, the quality parameters of 409 samples were determined using standard methods, and their spectra were acquired in ranges of 4000-650 cm -1 . The use of the multivariate filters, generalized least squares weighting (GLSW) and orthogonal signal correction (OSC), was evaluated to improve the signal-to-noise ratio of the models. Likewise, four variable selection approaches were tested: manual exclusion, forward interval PLS (FiPLS), backward interval PLS (BiPLS), and genetic algorithm (GA). The multivariate filters and variables selection algorithms generated more fitted and accurate PLS models. According to the validation, the FTIR/PLS models presented accuracy comparable to the reference methods and, therefore, the proposed method can be applied in the diesel routine monitoring to significantly reduce costs and analysis time.

  4. Rapid and Simultaneous Prediction of Eight Diesel Quality Parameters through ATR-FTIR Analysis

    PubMed Central

    Hatanaka, Rafael Rodrigues; Flumignan, Danilo Luiz; de Oliveira, José Eduardo

    2018-01-01

    Quality assessment of diesel fuel is highly necessary for society, but the costs and time spent are very high while using standard methods. Therefore, this study aimed to develop an analytical method capable of simultaneously determining eight diesel quality parameters (density; flash point; total sulfur content; distillation temperatures at 10% (T10), 50% (T50), and 85% (T85) recovery; cetane index; and biodiesel content) through attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy and the multivariate regression method, partial least square (PLS). For this purpose, the quality parameters of 409 samples were determined using standard methods, and their spectra were acquired in ranges of 4000–650 cm−1. The use of the multivariate filters, generalized least squares weighting (GLSW) and orthogonal signal correction (OSC), was evaluated to improve the signal-to-noise ratio of the models. Likewise, four variable selection approaches were tested: manual exclusion, forward interval PLS (FiPLS), backward interval PLS (BiPLS), and genetic algorithm (GA). The multivariate filters and variables selection algorithms generated more fitted and accurate PLS models. According to the validation, the FTIR/PLS models presented accuracy comparable to the reference methods and, therefore, the proposed method can be applied in the diesel routine monitoring to significantly reduce costs and analysis time. PMID:29629209

  5. Automated mass spectrometer analysis system

    NASA Technical Reports Server (NTRS)

    Giffin, Charles E. (Inventor); Kuppermann, Aron (Inventor); Dreyer, William J. (Inventor); Boettger, Heinz G. (Inventor)

    1982-01-01

    An automated mass spectrometer analysis system is disclosed, in which samples are automatically processed in a sample processor and converted into volatilizable samples, or their characteristic volatilizable derivatives. Each volatilizable sample is sequentially volatilized and analyzed in a double focusing mass spectrometer, whose output is in the form of separate ion beams all of which are simultaneously focused in a focal plane. Each ion beam is indicative of a different sample component or different fragments of one or more sample components and the beam intensity is related to the relative abundance of the sample component. The system includes an electro-optical ion detector which automatically and simultaneously converts the ion beams, first into electron beams which in turn produce a related image which is transferred to the target of a vilicon unit. The latter converts the images into electrical signals which are supplied to a data processor, whose output is a list of the components of the analyzed sample and their abundances. The system is under the control of a master control unit, which in addition to monitoring and controlling various power sources, controls the automatic operation of the system under expected and some unexpected conditions and further protects various critical parts of the system from damage due to particularly abnormal conditions.

  6. Frequency scanning interferometry in ATLAS: remote, multiple, simultaneous and precise distance measurements in a hostile environment

    NASA Astrophysics Data System (ADS)

    Coe, P. A.; Howell, D. F.; Nickerson, R. B.

    2004-11-01

    ATLAS is the largest particle detector under construction at CERN Geneva. Frequency scanning interferometry (FSI), also known as absolute distance interferometry, will be used to monitor shape changes of the SCT (semiconductor tracker), a particle tracker in the inaccessible, high radiation environment at the centre of ATLAS. Geodetic grids with several hundred fibre-coupled interferometers (30 mm to 1.5 m long) will be measured simultaneously. These lengths will be measured by tuning two lasers and comparing the resulting phase shifts in grid line interferometers (GLIs) with phase shifts in a reference interferometer. The novel inexpensive GLI design uses diverging beams to reduce sensitivity to misalignment, albeit with weaker signals. One micrometre precision length measurements of grid lines will allow 10 µm precision tracker shape corrections to be fed into ATLAS particle tracking analysis. The technique was demonstrated by measuring a 400 mm interferometer to better than 400 nm and a 1195 mm interferometer to better than 250 nm. Precise measurements were possible, even with poor quality signals, using numerical analysis of thousands of intensity samples. Errors due to drifts in interferometer length were substantially reduced using two lasers tuned in opposite directions and the precision was further improved by linking measurements made at widely separated laser frequencies.

  7. Automated mass spectrometer analysis system

    NASA Technical Reports Server (NTRS)

    Boettger, Heinz G. (Inventor); Giffin, Charles E. (Inventor); Dreyer, William J. (Inventor); Kuppermann, Aron (Inventor)

    1978-01-01

    An automated mass spectrometer analysis system is disclosed, in which samples are automatically processed in a sample processor and converted into volatilizable samples, or their characteristic volatilizable derivatives. Each volatizable sample is sequentially volatilized and analyzed in a double focusing mass spectrometer, whose output is in the form of separate ion beams all of which are simultaneously focused in a focal plane. Each ion beam is indicative of a different sample component or different fragments of one or more sample components and the beam intensity is related to the relative abundance of the sample component. The system includes an electro-optical ion detector which automatically and simultaneously converts the ion beams, first into electron beams which in turn produce a related image which is transferred to the target of a vidicon unit. The latter converts the images into electrical signals which are supplied to a data processor, whose output is a list of the components of the analyzed sample and their abundances. The system is under the control of a master control unit, which in addition to monitoring and controlling various power sources, controls the automatic operation of the system under expected and some unexpected conditions and further protects various critical parts of the system from damage due to particularly abnormal conditions.

  8. Prototype development of an electrical impedance based simultaneous respiratory and cardiac monitoring system for gated radiotherapy.

    PubMed

    Kohli, Kirpal; Liu, Jeff; Schellenberg, Devin; Karvat, Anand; Parameswaran, Ash; Grewal, Parvind; Thomas, Steven

    2014-10-14

    In radiotherapy, temporary translocations of the internal organs and tumor induced by respiratory and cardiac activities can undesirably lead to significantly lower radiation dose on the targeted tumor but more harmful radiation on surrounding healthy tissues. Respiratory and cardiac gated radiotherapy offers a potential solution for the treatment of tumors located in the upper thorax. The present study focuses on the design and development of simultaneous acquisition of respiratory and cardiac signal using electrical impedance technology for use in dual gated radiotherapy. An electronic circuitry was developed for monitoring the bio-impedance change due to respiratory and cardiac motions and extracting the cardiogenic ECG signal. The system was analyzed in terms of reliability of signal acquisition, time delay, and functionality in a high energy radiation environment. The resulting signal of the system developed was also compared with the output of the commercially available Real-time Position Management™ (RPM) system in both time and frequency domains. The results demonstrate that the bioimpedance-based method can potentially provide reliable tracking of respiratory and cardiac motion in humans, alternative to currently available methods. When compared with the RPM system, the impedance-based system developed in the present study shows similar output pattern but different sensitivities in monitoring different respiratory rates. The tracking of cardiac motion was more susceptible to interference from other sources than respiratory motion but also provided synchronous output compared with the ECG signal extracted. The proposed hardware-based implementation was observed to have a worst-case time delay of approximately 33 ms for respiratory monitoring and 45 ms for cardiac monitoring. No significant effect on the functionality of the system was observed when it was tested in a radiation environment with the electrode lead wires directly exposed to high-energy X-Rays. The developed system capable of rendering quality signals for tracking both respiratory and cardiac motions can potentially provide a solution for simultaneous dual-gated radiotherapy.

  9. Simultaneous acoustic and dielectric real time curing monitoring of epoxy systems

    NASA Astrophysics Data System (ADS)

    Gkikas, G.; Saganas, Ch.; Grammatikos, S. A.; Aggelis, D. G.; Paipetis, A. S.

    2012-04-01

    The attainment of structural integrity of the reinforcing matrix in composite materials is of primary importance for the final properties of the composite structure. The detailed monitoring of the curing process on the other hand is paramount (i) in defining the optimal conditions for the impregnation of the reinforcement by the matrix (ii) in limiting the effects of the exotherm produced by the polymerization reaction which create unwanted thermal stresses and (iii) in securing optimal behavior in matrix controlled properties, such as off axis or shear properties and in general the durability of the composite. Dielectric curing monitoring is a well known technique for distinguishing between the different stages of the polymerization of a typical epoxy system. The technique successfully predicts the gelation and the vitrification of the epoxy and has been extended for the monitoring of prepregs. Recent work has shown that distinct changes in the properties of the propagated sound in the epoxy which undergoes polymerization is as well directly related to the gelation and vitrification of the resin, as well as to the attainment of the final properties of the resin system. In this work, a typical epoxy is simultaneously monitored using acoustic and dielectric methods. The system is isothermally cured in an oven to avoid effects from the polymerization exotherm. Typical broadband sensors are employed for the acoustic monitoring, while flat interdigital sensors are employed for the dielectric scans. All stages of the polymerization process were successfully monitored and the validity of both methods was cross checked and verified.

  10. Real-time nutrient monitoring in rivers: adaptive sampling strategies, technological challenges and future directions

    NASA Astrophysics Data System (ADS)

    Blaen, Phillip; Khamis, Kieran; Lloyd, Charlotte; Bradley, Chris

    2016-04-01

    Excessive nutrient concentrations in river waters threaten aquatic ecosystem functioning and can pose substantial risks to human health. Robust monitoring strategies are therefore required to generate reliable estimates of river nutrient loads and to improve understanding of the catchment processes that drive spatiotemporal patterns in nutrient fluxes. Furthermore, these data are vital for prediction of future trends under changing environmental conditions and thus the development of appropriate mitigation measures. In recent years, technological developments have led to an increase in the use of continuous in-situ nutrient analysers, which enable measurements at far higher temporal resolutions than can be achieved with discrete sampling and subsequent laboratory analysis. However, such instruments can be costly to run and difficult to maintain (e.g. due to high power consumption and memory requirements), leading to trade-offs between temporal and spatial monitoring resolutions. Here, we highlight how adaptive monitoring strategies, comprising a mixture of temporal sample frequencies controlled by one or more 'trigger variables' (e.g. river stage, turbidity, or nutrient concentration), can advance our understanding of catchment nutrient dynamics while simultaneously overcoming many of the practical and economic challenges encountered in typical in-situ river nutrient monitoring applications. We present examples of short-term variability in river nutrient dynamics, driven by complex catchment behaviour, which support our case for the development of monitoring systems that can adapt in real-time to rapid environmental changes. In addition, we discuss the advantages and disadvantages of current nutrient monitoring techniques, and suggest new research directions based on emerging technologies and highlight how these might improve: 1) monitoring strategies, and 2) understanding of linkages between catchment processes and river nutrient fluxes.

  11. Design of a piezoelectric-based structural health monitoring system for damage detection in composite materials

    NASA Astrophysics Data System (ADS)

    Kessler, Seth S.; Spearing, S. Mark

    2002-07-01

    Cost-effective and reliable damage detection is critical for the utilization of composite materials. This paper presents the conclusions of an experimental and analytical survey of candidate methods for in-situ damage detection in composite structures. Experimental results are presented for the application of modal analysis and Lamb wave techniques to quasi-isotropic graphite/epoxy test specimens containing representative damage. Piezoelectric patches were used as actuators and sensors for both sets of experiments. Modal analysis methods were reliable for detecting small amounts of global damage in a simple composite structure. By comparison, Lamb wave methods were sensitive to all types of local damage present between the sensor and actuator, provided useful information about damage presence and severity, and present the possibility of estimating damage type and location. Analogous experiments were also performed for more complex built-up structures. These techniques are suitable for structural health monitoring applications since they can be applied with low power conformable sensors and can provide useful information about the state of a structure during operation. Piezoelectric patches could also be used as multipurpose sensors to detect damage by a variety of methods such as modal analysis, Lamb wave, acoustic emission and strain based methods simultaneously, by altering driving frequencies and sampling rates. This paper present guidelines and recommendations drawn from this research to assist in the design of a structural health monitoring system for a vehicle. These systems will be an important component in future designs of air and spacecraft to increase the feasibility of their missions.

  12. MRMPROBS: a data assessment and metabolite identification tool for large-scale multiple reaction monitoring based widely targeted metabolomics.

    PubMed

    Tsugawa, Hiroshi; Arita, Masanori; Kanazawa, Mitsuhiro; Ogiwara, Atsushi; Bamba, Takeshi; Fukusaki, Eiichiro

    2013-05-21

    We developed a new software program, MRMPROBS, for widely targeted metabolomics by using the large-scale multiple reaction monitoring (MRM) mode. The strategy became increasingly popular for the simultaneous analysis of up to several hundred metabolites at high sensitivity, selectivity, and quantitative capability. However, the traditional method of assessing measured metabolomics data without probabilistic criteria is not only time-consuming but is often subjective and makeshift work. Our program overcomes these problems by detecting and identifying metabolites automatically, by separating isomeric metabolites, and by removing background noise using a probabilistic score defined as the odds ratio from an optimized multivariate logistic regression model. Our software program also provides a user-friendly graphical interface to curate and organize data matrices and to apply principal component analyses and statistical tests. For a demonstration, we conducted a widely targeted metabolome analysis (152 metabolites) of propagating Saccharomyces cerevisiae measured at 15 time points by gas and liquid chromatography coupled to triple quadrupole mass spectrometry. MRMPROBS is a useful and practical tool for the assessment of large-scale MRM data available to any instrument or any experimental condition.

  13. Use of NMR-Based Metabolomics To Chemically Characterize the Roasting Process of Chicory Root.

    PubMed

    Wei, Feifei; Furihata, Kazuo; Zhang, Mimin; Miyakawa, Takuya; Tanokura, Masaru

    2016-08-16

    Roasted chicory root (Cichorium intybus) has been widely accepted as the most important coffee substitute. In this study, a nuclear magnetic resonance (NMR)-based comprehensive analysis was performed to monitor the substantial changes in the composition of chicory root during the roasting process. A detailed signal assignment of dried raw and roasted chicory roots was carried out using 1 H, 13 C, 1 H- 1 H DQF-COSY, 1 H- 13 C edited-HSQC, 1 H- 13 C CT-HMBC, and 1 H- 13 C HSQC-TOCSY NMR spectra. On the basis of the signal assignments, 36 NMR-visible components were monitored simultaneously during roasting. Inulins, sucrose, and most of the amino acids were largely degraded during the roasting process, whereas monosaccharides decreased at the beginning and then increased until the dark roasting stage. Acetamide, 5-hydroxymethylfurfural, di-d-fructose dianhydride, and norfuraneol were newly formed during roasting. Furthermore, a principal component analysis score plot indicated that similar chemical composition profiles could be achieved by roasting the chicory root either at a higher firepower for a shorter time or at a lower firepower for a longer time.

  14. Simultaneous quantification of lenalidomide, ibrutinib and its active metabolite PCI-45227 in rat plasma by LC-MS/MS: application to a pharmacokinetic study.

    PubMed

    Veeraraghavan, Sridhar; Viswanadha, Srikant; Thappali, Satheeshmanikandan; Govindarajulu, Babu; Vakkalanka, Swaroopkumar; Rangasamy, Manivannan

    2015-03-25

    Efficacy assessments using a combination of ibrutinib and lenalidomide necessitate the development of an analytical method for determination of both drugs in plasma with precision. A high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the simultaneous determination of lenalidomide, ibrutinib, and its active metabolite PCI45227 in rat plasma. Extraction of lenalidomide, ibrutinib, PCI45227 and tolbutamide (internal standard; IS) from 50 μl rat plasma was carried out by liquid-liquid extraction with ethyl acetate:dichloromethane (90:10) ratio. Chromatographic separation of analytes was performed on YMC pack ODS AM (150 mm × 4.6 mm, 5 μm) column under gradient conditions with acetonitrile:0.1% formic acid buffer as the mobile phases at a flow rate of 1 ml/min. Precursor ion and product ion transition for analytes and IS were monitored on a triple quadrupole mass spectrometer, operated in the selective reaction monitoring with positive ionization mode. Method was validated over a concentration range of 0.72-183.20 ng/ml for ibrutinib, 0.76-194.33 ng/ml for PCI-45227 and 1.87-479.16 ng/ml for lenalidomide. Mean extraction recovery for ibrutinib, PCI-45227, lenalidomide and IS of 75.2%, 84.5%, 97.3% and 92.3% were consistent across low, medium, and high QC levels. Precision and accuracy at low, medium and high quality control levels were less than 15% across analytes. Bench top, wet, freeze-thaw and long term stability was evaluated for all the analytes. The analytical method was applied to support a pharmacokinetic study of simultaneous estimation of lenalidomide, ibrutinib, and its active metabolite PCI-45227 in Wistar rat. Assay reproducibility was demonstrated by re-analysis of 18 incurred samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Eyeglasses based wireless electrolyte and metabolite sensor platform.

    PubMed

    Sempionatto, Juliane R; Nakagawa, Tatsuo; Pavinatto, Adriana; Mensah, Samantha T; Imani, Somayeh; Mercier, Patrick; Wang, Joseph

    2017-05-16

    The demand for wearable sensors has grown rapidly in recent years, with increasing attention being given to epidermal chemical sensing. Here, we present the first example of a fully integrated eyeglasses wireless multiplexed chemical sensing platform capable of real-time monitoring of sweat electrolytes and metabolites. The new concept has been realized by integrating an amperometric lactate biosensor and a potentiometric potassium ion-selective electrode into the two nose-bridge pads of the glasses and interfacing them with a wireless electronic backbone placed on the glasses' arms. Simultaneous real-time monitoring of sweat lactate and potassium levels with no apparent cross-talk is demonstrated along with wireless signal transduction. The electrochemical sensors were screen-printed on polyethylene terephthalate (PET) stickers and placed on each side of the glasses' nose pads in order to monitor sweat metabolites and electrolytes. The electronic backbone on the arms of the glasses' frame offers control of the amperometric and potentiometric transducers and enables Bluetooth wireless data transmission to the host device. The new eyeglasses system offers an interchangeable-sensor feature in connection with a variety of different nose-bridge amperometric and potentiometric sensor stickers. For example, the lactate bridge-pad sensor was replaced with a glucose one to offer convenient monitoring of sweat glucose. Such a fully integrated wireless "Lab-on-a-Glass" multiplexed biosensor platform can be readily expanded for the simultaneous monitoring of additional sweat electrolytes and metabolites.

  16. Simultaneously multiparametric spectroscopic monitoring of tissue viability in the brain and small intestine

    NASA Astrophysics Data System (ADS)

    Tolmasov, Michael; Barbiro-Michaely, Efrat; Mayevsky, Avraham

    2007-02-01

    Under body O II imbalance, the Autonomic Nervous System is responsible for redistribution of blood flow with preference to the most vital organs (brain, heart), while the less vital organs (intestine, GI tract) are hypoperfused. The aim of this study was to develop and use an animal model for real time monitoring of tissue viability in the brain, and the small intestine, under various levels of oxygen and blood supply. Male Wistar rats were anesthetized, the brain cortex and intestinal serosa were exposed and connected by optical fibers to the Multi-Site Multi-Parametric (MSMP) monitoring system. Tissue blood flow (TBF) and mitochondrial NADH redox state were monitored simultaneously in the two organs. The rats were subjected to short anoxia, 20 minutes hypoxia or epinephrine (2& 8μg/kg I.V.). Under oxygen deficiency, cerebral blood flow (CBF) was elevated, whereas intestinal TBF was reduced. Mitochondrial NADH was significantly elevated in both organs. Systemic injection of Adrenaline showed a dose-depended increase in systemic blood pressure and CBF response whereas, intestinal TBF similarly decreased in both doses. In addition, NADH was elevated (reduced form) in the intestine whereas oxidation was observed in the brain. In conclusion, our preliminary results may imply the ability of using of the MSMP for monitoring non-vital organs in order to detect early changes in the balance between oxygen supply and demand in the body.

  17. Multicomponent Breath Analysis With Infrared Absorption Using Room-Temperature Quantum Cascade Lasers

    PubMed Central

    Shorter, Joanne H.; Nelson, David D.; Barry McManus, J.; Zahniser, Mark S.; Milton, Donald K.

    2010-01-01

    Breath analysis is a powerful noninvasive technique for the diagnosis and monitoring of respiratory diseases, including asthma and chronic obstructive pulmonary disease (COPD). Nitric oxide (NO) and carbon monoxide (CO) are markers of airway inflammation and can indicate the extent of respiratory diseases. We have developed a compact fast response laser system for analysis of multiple gases by infrared absorption. The instrument uses room temperature quantum cascade lasers to simultaneously measure NO, CO, carbon dioxide (CO2) and nitrous oxide (N2O) in exhaled breath. Four breath flow rates are employed to explore their exchange dynamics in the lungs and airways. We obtain 1-s detection precisions of 0.5-0.8 parts-per-billion (ppb) for NO, CO, and N2O with an instrument response time of less than 1 s. The breath analysis system has been demonstrated in a preliminary study of volunteers. It is currently deployed in a trial clinical study. PMID:20697459

  18. Monitoring of CoS 2 reactions using high-temperature XRD coupled with gas chromatography (GC)

    DOE PAGES

    Rodriguez, Mark A.; Coker, Eric Nicholas; Griego, James J. M.; ...

    2016-04-18

    High-temperature X-ray diffraction with concurrent gas chromatography (GC) was used to study cobalt disulfide cathode pellets disassembled from thermal batteries. When CoS 2 cathode materials were analyzed in an air environment, oxidation of the K(Br, Cl) salt phase in the cathode led to the formation of K 2SO 4 that subsequently reacted with the pyrite-type CoS 2 phase leading to cathode decomposition between ~260 and 450 °C. Here, independent thermal analysis experiments, i.e. simultaneous thermogravimetric analysis/differential scanning calorimetry/mass spectrometry (MS), augmented the diffraction results and support the overall picture of CoS 2 decomposition. Both gas analysis measurements (i.e. GC andmore » MS) from the independent experiments confirmed the formation of SO 2 off-gas species during breakdown of the CoS 2. In contrast, characterization of the same cathode material under inert conditions showed the presence of CoS 2 throughout the entire temperature range of analysis.« less

  19. Inverse procedure for simultaneous evaluation of viscosity and density of Newtonian liquids from dispersion curves of Love waves

    NASA Astrophysics Data System (ADS)

    Kiełczyński, P.; Szalewski, M.; Balcerzak, A.

    2014-07-01

    Simultaneous determination of the viscosity and density of liquids is of great importance in the monitoring of technological processes in the chemical, petroleum, and pharmaceutical industry, as well as in geophysics. In this paper, the authors present the application of Love waves for simultaneous inverse determination of the viscosity and density of liquids. The inversion procedure is based on measurements of the dispersion curves of phase velocity and attenuation of ultrasonic Love waves. The direct problem of the Love wave propagation in a layered waveguide covered by a viscous liquid was formulated and solved. Love waves propagate in an elastic layered waveguide covered on its surface with a viscous (Newtonian) liquid. The inverse problem is formulated as an optimization problem with appropriately constructed objective function that depends on the material properties of an elastic waveguide of the Love wave, material parameters of a liquid (i.e., viscosity and density), and the experimental data. The results of numerical calculations show that Love waves can be efficiently applied to determine simultaneously the physical properties of liquids (i.e., viscosity and density). Sensors based on this method can be very attractive for industrial applications to monitor on-line the parameters (density and viscosity) of process liquid during the course of technological processes, e.g., in polymer industry.

  20. Evaluation of an aerosol photometer for monitoring welding fume levels in a shipyard.

    PubMed

    Glinsmann, P W; Rosenthal, F S

    1985-07-01

    A direct reading aerosol photometer (Sibata P-5 Digital Dust Indicator) was used to assess fume levels from welding and burning operations in a shipyard. The photometer was calibrated with gravimetric analysis of filter samples collected simultaneously with instrument readings. A six-fold difference between calibration factors for personal and area samples was found. This difference can be explained by expected changes in particle size distributions in welding fume. Monitoring of various work situations was performed in order to assess the value of the photometer for the measurement of fume. Measurements categorized by enclosure of space and quality of ventilation indicated the presence of high fume levels in semi-enclosed and enclosed spaces. The build up of welding fume in an enclosed space occurred over several minutes after the arc was struck. Decay likewise required several minutes. During welding, wide fluctuations of fume concentrations were found. Thus a single reading was not adequate to characterize average fume levels. Although this type of instrument is useful for locating areas with high fume levels and monitoring the effectiveness of ventilation, the uncertainty in calibration factors makes accurate determinations of fume levels difficult.

  1. A new analysis method using Bragg curve spectroscopy for a Multi-purpose Active-target Particle Telescope for radiation monitoring

    NASA Astrophysics Data System (ADS)

    Losekamm, M. J.; Milde, M.; Pöschl, T.; Greenwald, D.; Paul, S.

    2017-02-01

    Traditional radiation detectors can either measure the total radiation dose omnidirectionally (dosimeters), or determine the incoming particles characteristics within a narrow field of view (spectrometers). Instantaneous measurements of anisotropic fluxes thus require several detectors, resulting in bulky setups. The Multi-purpose Active-target Particle Telescope (MAPT), employing a new detection principle, is designed to measure particle fluxes omnidirectionally and be simultaneously a dosimeter and spectrometer. It consists of an active core of scintillating fibers whose light output is measured by silicon photomultipliers, and fits into a cube with an edge length of 10 cm. It identifies particles using extended Bragg curve spectroscopy, with sensitivity to charged particles with kinetic energies above 25 MeV. MAPT's unique layout results in a geometrical acceptance of approximately 800 cm2 sr and an angular resolution of less than 6°, which can be improved by track-fitting procedures. In a beam test of a simplified prototype, the energy resolution was found to be less than 1 MeV for protons with energies between 30 and 70 MeV. Possible applications of MAPT include the monitoring of radiation environments in spacecraft and beam monitoring in medical facilities.

  2. A reliable and rapid tool for plasma quantification of 18 psychotropic drugs by ESI tandem mass spectrometry.

    PubMed

    Vecchione, Gennaro; Casetta, Bruno; Chiapparino, Antonella; Bertolino, Alessandro; Tomaiuolo, Michela; Cappucci, Filomena; Gatta, Raffaella; Margaglione, Maurizio; Grandone, Elvira

    2012-01-01

    A simple liquid chromatographic tandem mass spectrometry (LC-MS/MS) method has been developed for simultaneous analysis of 17 basic and one acid psychotropic drugs in human plasma. The method relies on a protein precipitation step for sample preparation and offers high sensitivity, wide linearity without interferences from endogenous matrix components. Chromatography was run on a reversed-phase column with an acetonitrile-H₂O mixture. The quantification of target compounds was performed in multiple reaction monitoring (MRM) and by switching the ionization polarity within the analytical run. A further sensitivity increase was obtained by implementing the functionality "scheduled multiple reaction monitoring" (sMRM) offered by the recent version of the software package managing the instrument. The overall injection interval was less than 5.5 min. Regression coefficients of the calibration curves and limits of quantification (LOQ) showed a good coverage of over-therapeutic, therapeutic and sub-therapeutic ranges. Recovery rates, measured as percentage of recovery of spiked plasma samples, were ≥ 94%. Precision and accuracy data have been satisfactory for a therapeutic drug monitoring (TDM) service as for managing plasma samples from patients receiving psycho-pharmacological treatment. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Range of protein detection by selected/multiple reaction monitoring mass spectrometry in an unfractionated human cell culture lysate.

    PubMed

    Ebhardt, H Alexander; Sabidó, Eduard; Hüttenhain, Ruth; Collins, Ben; Aebersold, Ruedi

    2012-04-01

    Selected or multiple reaction monitoring is a targeted mass spectrometry method (S/MRM-MS), in which many peptides are simultaneously and consistently analyzed during a single liquid chromatography-mass spectrometry (LC-S/MRM-MS) measurement. These capabilities make S/MRM-MS an attractive method to monitor a consistent set of proteins over various experimental conditions. To increase throughput for S/MRM-MS it is advantageous to use scheduled methods and unfractionated protein extracts. Here, we established the practically measurable dynamic range of proteins reliably detectable and quantifiable in an unfractionated protein extract from a human cell line using LC-S/MRM-MS. Initially, we analyzed S/MRM transition peak groups in terms of interfering signals and compared S/MRM transition peak groups to MS1-triggered MS2 spectra using dot-product analysis. Finally, using unfractionated protein extract from human cell lysate, we quantified the upper boundary of copies per cell to be 35 million copies per cell, while 7500 copies per cell represents a lower boundary using a single 35 min linear gradient LC-S/MRM-MS measurement on a current, standard commercial instrument. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Modal parameter estimation and monitoring for on-line flight flutter analysis

    NASA Astrophysics Data System (ADS)

    Verboven, P.; Cauberghe, B.; Guillaume, P.; Vanlanduit, S.; Parloo, E.

    2004-05-01

    The clearance of the flight envelope of a new airplane by means of flight flutter testing is time consuming and expensive. Most common approach is to track the modal damping ratios during a number of flight conditions, and hence the accuracy of the damping estimates plays a crucial role. However, aircraft manufacturers desire to decrease the flight flutter testing time for practical, safety and economical reasons by evolving from discrete flight test points to a more continuous flight test pattern. Therefore, this paper presents an approach that provides modal parameter estimation and monitoring for an aircraft with a slowly time-varying structural behaviour that will be observed during a faster and more continuous exploration of the flight envelope. The proposed identification approach estimates the modal parameters directly from input/output Fourier data. This avoids the need for an averaging-based pre-processing of the data, which becomes inapplicable in the case that only short data records are measured. Instead of using a Hanning window to reduce effects of leakage, these transient effects are modelled simultaneously with the dynamical behaviour of the airplane. The method is validated for the monitoring of the system poles during flight flutter testing.

  5. Simultaneous Proteomic Discovery and Targeted Monitoring using Liquid Chromatography, Ion Mobility Spectrometry, and Mass Spectrometry*

    PubMed Central

    Burnum-Johnson, Kristin E.; Nie, Song; Casey, Cameron P.; Monroe, Matthew E.; Orton, Daniel J.; Ibrahim, Yehia M.; Gritsenko, Marina A.; Clauss, Therese R. W.; Shukla, Anil K.; Moore, Ronald J.; Purvine, Samuel O.; Shi, Tujin; Qian, Weijun; Liu, Tao; Baker, Erin S.; Smith, Richard D.

    2016-01-01

    Current proteomic approaches include both broad discovery measurements and quantitative targeted analyses. In many cases, discovery measurements are initially used to identify potentially important proteins (e.g. candidate biomarkers) and then targeted studies are employed to quantify a limited number of selected proteins. Both approaches, however, suffer from limitations. Discovery measurements aim to sample the whole proteome but have lower sensitivity, accuracy, and quantitation precision than targeted approaches, whereas targeted measurements are significantly more sensitive but only sample a limited portion of the proteome. Herein, we describe a new approach that performs both discovery and targeted monitoring (DTM) in a single analysis by combining liquid chromatography, ion mobility spectrometry and mass spectrometry (LC-IMS-MS). In DTM, heavy labeled target peptides are spiked into tryptic digests and both the labeled and unlabeled peptides are detected using LC-IMS-MS instrumentation. Compared with the broad LC-MS discovery measurements, DTM yields greater peptide/protein coverage and detects lower abundance species. DTM also achieved detection limits similar to selected reaction monitoring (SRM) indicating its potential for combined high quality discovery and targeted analyses, which is a significant step toward the convergence of discovery and targeted approaches. PMID:27670688

  6. A novel real-time health monitoring system for unmanned vehicles

    NASA Astrophysics Data System (ADS)

    Zhang, David C.; Ouyang, Lien; Qing, Peter; Li, Irene

    2008-04-01

    Real-time monitoring the status of in-service structures such as unmanned vehicles can provide invaluable information to detect the damages to the structures on time. The unmanned vehicles can be maintained and repaired in time if such damages are found. One typical cause of damages of unmanned vehicles is from impacts caused by bumping into some obstacles or being hit by some objects such as hostile fire. This paper introduces a novel impact event sensing system that can detect the location of the impact events and the force-time history of the impact events. The system consists of the Piezo-electric sensor network, the hardware platform and the analysis software. The new customized battery-powered impact event sensing system supports up to 64-channel parallel data acquisition. It features an innovative low-power hardware trigger circuit that monitors 64 channels simultaneously. The system is in the sleep mode most of the time. When an impact event happens, the system will wake up in micro-seconds and detect the impact location and corresponding force-time history. The system can be combined with the SMART sensing system to further evaluate the impact damage severity.

  7. Soluble Protein Analysis using a Compact Bench-top Flow Cytometer

    NASA Technical Reports Server (NTRS)

    Pappas, Dimitri; Kao, Shib-Hsin; Cyr, Johnathan

    2004-01-01

    Future space exploration missions will require analytical technology capable of providing both autonomous medical care to the crew and investigative capabilities to researchers. While several promising candidate technologies exist for further development, flow cytometry is an attractive technology as it offers both crew health (blood cell count, leukocyte differential, etc.) and a wide array of biochemistry and immunology assays. research settings, the application of this technique to soluble protein analysis is also possible. Proteomic beads using fluorescent dyes for optical encoding were used to monitor six cytokines simultaneously in cell medium of cell cultures in stationary and rotating cell culture systems. The results of this work demonstrate that a compact flow cytometer, such as a system proposed for space flight, can detect a variety of soluble proteins for crew health and biotechnology experiments during long-term missions.

  8. In-Situ Measurement of Power Loss for Crystalline Silicon Modules Undergoing Thermal Cycling and Mechanical Loading Stress Testing: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spataru, Sergiu; Hacke, Pater; Sera, Dezso

    2015-09-15

    We analyze the degradation of multi-crystalline silicon photovoltaic modules undergoing simultaneous thermal, mechanical, and humidity stress testing to develop a dark environmental chamber in-situ measurement procedure for determining module power loss. From the analysis we determine three main categories of failure modes associated with the module degradation consisting of: shunting, recombination losses, increased series resistance losses, and current mismatch losses associated with a decrease in photo-current generation by removal of some cell areas due to cell fractures. Based on the analysis, we propose an in-situ module power loss monitoring procedure that relies on dark current-voltage measurements taken during the stressmore » test, and initial and final module flash testing, to determine the power degradation characteristic of the module.« less

  9. Evaluating the accuracy, reliability, and clinical applicability of continuous glucose monitoring (CGM): Is CGM ready for real time?

    PubMed

    Mazze, Roger S; Strock, Ellie; Borgman, Sarah; Wesley, David; Stout, Philip; Racchini, Joel

    2009-01-01

    This study was designed to assess the accuracy, reliability, and contribution to clinical decision-making of two commercially available continuous glucose monitoring (CGM) devices using a novel analytical approach. Eleven individuals with type 1 diabetes and five with type 2 diabetes wore a Guardian RT (GRT) (Medtronic Minimed, Northridge, CA) or DexCom STS Continuous Monitoring System (DEX) (San Diego, CA) device for 200 h followed by an 8-h laboratory study. A subset of these subjects wore both devices simultaneously. Subjects produced 1,902 +/- 269 readings during the ambulatory phase. During the laboratory study we found: lag time of 21 +/- 5 min for GRT and 7 +/- 7 min for DEX (P < 0.005); mean absolute relative difference of 19.9% and 16.7%, respectively, for GRT and DEX; and glucose exposure (the ratio of study device/laboratory reference device [YSI Instruments, Inc., Yellow Springs, OH] area under the curve) of 95 +/- 6% for GRT and 101 +/- 13% for DEX. Reliability measured during laboratory study showed 82% for DEX and 99% for GRT. Clarke Error Grid analysis (YSI reference) showed for GRT 59% of values in zone A, 34% in zone B, and 7% in zone D and for DEX 70% in zone A, 28% in zone B, 1% in zone C, and 1% in zone D. Bland-Altman plots (YSI standard) yielded for DEX 3 mg/dL (95% confidence interval, -78 to 84 mg/dL) and for GRT -21 mg/dL (95% confidence interval, -124 to 82 mg/dL). Six of eight subjects completed both home and laboratory simultaneous use of DEX and GRT. Lag times were inconsistent between devices, ranging from 0 to 32 min; area under the curve revealed a tendency for DEX to report higher total glucose exposure than GRT for the same patient. CGM detects abnormalities in glycemic control in a manner heretofore impossible to obtain. However, our studies revealed sufficient incongruence between simultaneous laboratory blood glucose levels and interstitial fluid glucose (after calibrations) to question the fundamental assumption that interstitial fluid glucose and blood glucose could be made identical by resorting to algorithms based on concurrent blood glucose levels alone.

  10. ATR-FTIR membrane-based sensor for the simultaneous determination of surfactant and oil total indices in industrial degreasing baths.

    PubMed

    Lucena, Rafael; Cárdenas, Soledad; Gallego, Mercedes; Valcárcel, Miguel

    2006-03-01

    Monitoring the exhaustion of alkaline degreasing baths is one of the main aspects in metal mechanizing industrial process control. The global level of surfactant, and mainly grease, can be used as ageing indicators. In this paper, an attenuated total reflection-Fourier transform infrared (ATR-FTIR) membrane-based sensor is presented for the determination of these parameters. The system is based on a micro-liquid-liquid extraction of the analytes through a polymeric membrane from the aqueous to the organic solvent layer which is in close contact with the internal reflection element and continuously monitored. Samples are automatically processed using a simple, robust sequential injection analysis (SIA) configuration, on-line coupled to the instrument. The global signal obtained for both families of compounds are processed via a multivariate calibration technique (partial least squares, PLS). Excellent correlation was obtained for the values given by the proposed method compared to those of the gravimetric reference one with very low error values for both calibration and validation.

  11. Monitoring of Water Spectral Pattern Reveals Differences in Probiotics Growth When Used for Rapid Bacteria Selection.

    PubMed

    Slavchev, Aleksandar; Kovacs, Zoltan; Koshiba, Haruki; Nagai, Airi; Bázár, György; Krastanov, Albert; Kubota, Yousuke; Tsenkova, Roumiana

    2015-01-01

    Development of efficient screening method coupled with cell functionality evaluation is highly needed in contemporary microbiology. The presented novel concept and fast non-destructive method brings in to play the water spectral pattern of the solution as a molecular fingerprint of the cell culture system. To elucidate the concept, NIR spectroscopy with Aquaphotomics were applied to monitor the growth of sixteen Lactobacillus bulgaricus one Lactobacillus pentosus and one Lactobacillus gasseri bacteria strains. Their growth rate, maximal optical density, low pH and bile tolerances were measured and further used as a reference data for analysis of the simultaneously acquired spectral data. The acquired spectral data in the region of 1100-1850nm was subjected to various multivariate data analyses - PCA, OPLS-DA, PLSR. The results showed high accuracy of bacteria strains classification according to their probiotic strength. Most informative spectral fingerprints covered the first overtone of water, emphasizing the relation of water molecular system to cell functionality.

  12. Combination of Multi-Agent Systems and Wireless Sensor Networks for the Monitoring of Cattle

    PubMed Central

    Barriuso, Alberto L.; De Paz, Juan F.; Lozano, Álvaro

    2018-01-01

    Precision breeding techniques have been widely used to optimize expenses and increase livestock yields. Notwithstanding, the joint use of heterogeneous sensors and artificial intelligence techniques for the simultaneous analysis or detection of different problems that cattle may present has not been addressed. This study arises from the necessity to obtain a technological tool that faces this state of the art limitation. As novelty, this work presents a multi-agent architecture based on virtual organizations which allows to deploy a new embedded agent model in computationally limited autonomous sensors, making use of the Platform for Automatic coNstruction of orGanizations of intElligent Agents (PANGEA). To validate the proposed platform, different studies have been performed, where parameters specific to each animal are studied, such as physical activity, temperature, estrus cycle state and the moment in which the animal goes into labor. In addition, a set of applications that allow farmers to remotely monitor the livestock have been developed. PMID:29301310

  13. An object-oriented approach to data display and storage: 3 years experience, 25,000 cases.

    PubMed

    Sainsbury, D A

    1993-11-01

    Object-oriented programming techniques were used to develop computer based data display and storage systems. These have been operating in the 8 anaesthetising areas of the Adelaide Children's Hospital for 3 years. The analogue and serial outputs from an array of patient monitors are connected to IBM compatible PC-XT computers. The information is displayed on a colour screen as wave-form and trend graphs and digital format in 'real time'. The trend data is printed simultaneously on a dot matrix printer. This data is also stored for 24 hours on 'hard' disk. The major benefit has been the provision of a single visual focus for all monitored variables. The automatic logging of data has been invaluable in the analysis of critical incidents. The systems were made possible by recent, rapid improvements in computer hardware and software. This paper traces the development of the program and demonstrates the advantages of object-oriented programming techniques.

  14. Outcome of intracranial electroencephalography monitoring and surgery in magnetic resonance imaging-negative temporal lobe epilepsy.

    PubMed

    Lee, Ricky W; Hoogs, Marietta M; Burkholder, David B; Trenerry, Max R; Drazkowski, Joseph F; Shih, Jerry J; Doll, Karey E; Tatum, William O; Cascino, Gregory D; Marsh, W Richard; Wirrell, Elaine C; Worrell, Gregory A; So, Elson L

    2014-07-01

    We evaluated the outcomes of intracranial electroencephalography (iEEG) recording and subsequent resective surgery in patients with magnetic resonance imaging (MRI)-negative temporal lobe epilepsy (TLE). Thirty-two patients were identified from the Mayo Clinic Epilepsy Surgery Database (Arizona, Florida, and Minnesota). Eight (25.0%) had chronic iEEG monitoring that recorded neocortical temporal seizure onsets; 12 (37.5%) had mesial temporal seizure onsets; 5 (15.6%) had independent neocortical and mesial temporal seizure onsets; and 7 (21.9%) had simultaneous neocortical and mesial seizure onsets. Neocortical temporal lobe seizure semiology was the only factor significantly associated with neocortical temporal seizure onsets on iEEG. Only 33.3% of patients who underwent lateral temporal neocorticectomy had an Engel class 1 outcome, whereas 76.5% of patients with iEEG-guided anterior temporal lobectomy that included the amygdala and the hippocampus had an Engel class 1 outcome. Limitations in cohort size precluded statistical analysis of neuropsychological test data. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Application of fluorescence and PARAFAC to assess vertical distribution of subsurface hydrocarbons and dispersant during the Deepwater Horizon oil spill.

    PubMed

    Mendoza, Wilson G; Riemer, Daniel D; Zika, Rod G

    2013-05-01

    We evaluated the use of excitation and emission matrix (EEM) fluorescence and parallel factorial analysis (PARAFAC) modeling techniques for monitoring crude oil components in the water column. Four of the seven derived PARAFAC loadings were associated with the Macondo crude oil components. The other three components were associated with the dispersant, an unresolved component and colored dissolved organic matter (CDOM). The fluorescence of the associated benzene and naphthalene-like components of crude oil exhibited a maximum at ∼1200 m. The maximum fluorescence of the component associated with the dispersant (i.e., Corexit EC9500A) was observed at the same depth. The plume observed at this depth was attributed to the dispersed crude oil from the Deepwater Horizon oil spill. Results demonstrate the application of EEM and PARAFAC to simultaneously monitor selected PAH, dispersant-containing and humic-like fluorescence components in the oil spill region in the Gulf of Mexico.

  16. Combination of Multi-Agent Systems and Wireless Sensor Networks for the Monitoring of Cattle.

    PubMed

    Barriuso, Alberto L; Villarrubia González, Gabriel; De Paz, Juan F; Lozano, Álvaro; Bajo, Javier

    2018-01-02

    Precision breeding techniques have been widely used to optimize expenses and increase livestock yields. Notwithstanding, the joint use of heterogeneous sensors and artificial intelligence techniques for the simultaneous analysis or detection of different problems that cattle may present has not been addressed. This study arises from the necessity to obtain a technological tool that faces this state of the art limitation. As novelty, this work presents a multi-agent architecture based on virtual organizations which allows to deploy a new embedded agent model in computationally limited autonomous sensors, making use of the Platform for Automatic coNstruction of orGanizations of intElligent Agents (PANGEA). To validate the proposed platform, different studies have been performed, where parameters specific to each animal are studied, such as physical activity, temperature, estrus cycle state and the moment in which the animal goes into labor. In addition, a set of applications that allow farmers to remotely monitor the livestock have been developed.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sanchez, Savannah E.; Cuevas, Daniel A.; Rostron, Jason E.

    Current investigations into phage-host interactions are dependent on extrapolating knowledge from (meta)genomes. Interestingly, 60 - 95% of all phage sequences share no homology to current annotated proteins. As a result, a large proportion of phage genes are annotated as hypothetical. This reality heavily affects the annotation of both structural and auxiliary metabolic genes. Here we present phenomic methods designed to capture the physiological response(s) of a selected host during expression of one of these unknown phage genes. Multi-phenotype Assay Plates (MAPs) are used to monitor the diversity of host substrate utilization and subsequent biomass formation, while metabolomics provides bi-product analysismore » by monitoring metabolite abundance and diversity. Both tools are used simultaneously to provide a phenotypic profile associated with expression of a single putative phage open reading frame (ORF). Thus, representative results for both methods are compared, highlighting the phenotypic profile differences of a host carrying either putative structural or metabolic phage genes. In addition, the visualization techniques and high throughput computational pipelines that facilitated experimental analysis are presented.« less

  18. Comparison of the Wake-up Test and Combined TES-MEP and CSEP Monitoring in Spinal Surgery.

    PubMed

    Chen, Bailing; Chen, Yuguang; Yang, Junlin; Xie, Denghui; Su, Haihua; Li, Fobao; Wan, Yong; Peng, Xinsheng; Zheng, Zhaomin

    2015-11-01

    A retrospective clinical analysis. The aim of this study was to compare the effectiveness of the wake-up test with that of combined monitoring of transcranial electrical stimulation motor evoked potentials (TES-MEP) and cortical somatosensory evoked potentials (CSEP) in spinal surgery. TES-MEP/CSEP combined monitoring is being increasingly recognized as the ideal approach to detect spinal neurophysiological compromise during spinal surgery; however, as a result the merit of the wake-up test is now in doubt. TES-MEP/CSEP combined monitoring was performed simultaneously in 426 patients who underwent spinal surgery at our department, and wake-up tests were conducted on 23 patients because of positive neurophysiological monitoring results with uncertain causes or persistent positive monitoring findings after all potential causes had been resolved. Preoperative and postoperative neurological examinations were performed as the gold standard to detect irreversible spinal function compromise. All data were collected to compare the efficiency of TES-MEP/CSEP combined monitoring with that of the wake-up test. Positive results of TES-MEP/CSEP combined monitoring were recorded in 64 cases. Among them, the positive monitoring findings agreed with the results of the neurological examination in 51 cases, and the monitoring results did not match that of neurological examination in 13 cases. No false-negative result was observed. The sensitivity of TES-MEP/CSEP monitoring was 100%, the specificity was 96.5%, and the Youden index was 0.965. Wake-up tests were conducted in 23 cases. In 8 patients the positive monitoring findings completely matched the postoperative neurological examination results. In contrast, in the other 15 cases with negative neurophysiological monitoring results, only 9 patients retained intact neurological function and 6 patients suffered compromised neurological function. The sensitivity of the wake-up test was 57.1%, the specificity was 100%, and the Youden index was 0.571. Combined TES-MEP and CSEP monitoring, with its high sensitivity and specificity, is an effective method for monitoring spinal function during surgery and should be the preferred choice. The wake-up test is a useful complementary method for monitoring because of its high specificity.

  19. Two-parameter monitoring in a lab-on-valve manifold, applied to intracellular H2O2 measurements.

    PubMed

    Lähdesmäki, Ilkka; Chocholous, Petr; Carroll, Andrea D; Anderson, Judy; Rabinovitch, Peter S; Ruzicka, Jaromir

    2009-07-01

    This work introduces, for the first time, simultaneous monitoring of fluorescence and absorbance using Bead Injection in a Lab-on-valve format. The aim of the paper is to show that when the target species, cells immobilized on a stationary phase, are exposed to reagents under well-controlled reaction conditions, dual monitoring yields valuable information. The applicability of this technique is demonstrated by the development of a Bead Injection method for automated measurement of cell density and intracellular hydrogen peroxide.

  20. Self-assembly of marine exudate particles and their impact on the CCN properties of nascent marine aerosol

    NASA Astrophysics Data System (ADS)

    Schill, S.; Zimmermann, K.; Ryder, O. S.; Campbell, N.; Collins, D. B.; Gianneschi, N.; Bertram, T. H.

    2013-12-01

    Spontaneous self-assembly of marine exudate particles has previously been observed in filtered seawater samples. The chemicophysical properties of these particles may alter the chemical composition and CCN properties of nascent marine aerosol, yet to date simultaneous measurement of seawater exudate particle formation rates and number distributions, with aerosol particle formation rates and CCN activity are lacking. Here, we use a novel Marine Aerosol Reference Tank (MART) system to experimentally mimic a phytoplankton bloom via sequential addition of biological surrogates, including sterol, galactose, lipopolysaccharide, BSA protein, and dipalmitoylphosphatidylcholine. Nascent sea-spray aerosol are generated in the MART system via a continuous plunging waterfall. Exudate particle assembly in the water is monitored via dynamic light scattering (DLS) and transmission electron microscopy (TEM) to obtain both the assembly kinetics of the particles as well as particle number distributions Simultaneous characterization of both particle production rates and super-saturated particle hygroscopicity are also discussed. This study permits analysis of the controlling role of the molecular composition of dissolved organic carbon in setting the production rates of colloidal material in the surface oceans.

  1. Design and daytime performance of laser-induced fluorescence spectrum lidar for simultaneous detection of multiple components, dissolved organic matter, phycocyanin, and chlorophyll in river water.

    PubMed

    Saito, Yasunori; Kakuda, Kei; Yokoyama, Mizuho; Kubota, Tomoki; Tomida, Takayuki; Park, Ho-Dong

    2016-08-20

    In this work, we developed mobile laser-induced fluorescence spectrum (LIFS) lidar based on preliminary experiments on the excitation emission matrix of a water sample and a method for reducing solar background light using the synchronous detection technique. The combination of a UV short-pulse laser (355 nm, 6 ns) for fluorescence excitation with a 10-100 ns short-time synchronous detection using a gated image-intensified multi-channel CCD of the fluorescence made the LIFS lidar operation possible even in daytime. The LIFS lidar with this construction demonstrated the potential of natural river/lake water quality monitoring at the Tenryu River/Lake Suwa. Three main components in the fluorescence data of the water, dissolved organic matter, phycocyanin, and chlorophyll, were extracted by spectral analysis using the standard spectral functions of these components. Their concentrations were estimated by adapting experimentally calibrated data. Results of long-term field observations using our LIFS lidar from 2010 to 2012 show the necessity of simultaneous multi-component detection to understand the natural water environment.

  2. The seed factor: how a combination of four observables can unveil the location of blazar GeV emission.

    NASA Astrophysics Data System (ADS)

    Harvey, Adam; Georganopoulos, Markos; Meyer, Eileen

    2018-01-01

    We present here a method for constraining the emission location of γ-rays in powerful, lined blazars (i.e., flat spectrum radio quasars (FSRQs)). We develop a diagnostic criteria, which we term the seed factor, to differentiate between γ-ray emission due to external Compton (EC) scattering in the broad line region (BLR) and the molecular torus (MT). The seed factor is determined entirely by four observable quantities; the synchrotron and inverse Compton (IC) peak frequencies, and the respective peak luminosities. It may thus be possible to use the seed factor to constrain the emission location in a model-independent way.We also present preliminary results of our analysis regarding the seed factor in quasi-simultaneous multi-wavelength SEDs from the Fermi LAT Bright AGN Sample (LBAS), historical data from the ASDC SED Builder of FSRQs in the the Monitoring Of Jets in Active galactic nuclei with VLBA Experiments (MOJAVE) sample, and quasi-simultaneous multi-wavelength SEDs from the Dynamic SEDs of southern blazars (DSSB) sample.

  3. PKS 2155-304 in July 2006: H.E.S.S. results and simultaneous multi-wavelength observations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lenain, Jean-Philippe; Boisson, Catherine; Sol, Helne

    2008-12-24

    The high-frequency-peaked BL Lac PKS 2155-304 is one of the brightest and best-studied VHE {gamma}-ray sources in the southern hemisphere. The High Energy Stereoscopic System (H.E.S.S.) has monitored PKS 2155-304 in 2006 and a multi-wavelength campaign involving X-ray, optical and radio observatories was triggered by the detection of an active state in July 2006, followed by the detection of two extraordinary flares on July, 28th and 30th, with peak fluxes {approx}100 times the usual values. We present results from the spectral and flux variability analysis of the VHE and simultaneous X-ray observations with Chandra during the second flare, as wellmore » as the detailed evolution of the VHE flux of PKS 2155-304 observed by H.E.S.S. in 2006. A study of flux correlations in the different frequency ranges during the second flare and the adjacent nights is discussed. We also present an interpretation of the active state of PKS 2155-304 in the framework of synchrotron self-Compton emission.« less

  4. Simultaneous assessment of phase chemistry, phase abundance and bulk chemistry with statistical electron probe micro-analyses: Application to cement clinkers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilson, William; Krakowiak, Konrad J.; Ulm, Franz-Josef, E-mail: ulm@mit.edu

    2014-01-15

    According to recent developments in cement clinker engineering, the optimization of chemical substitutions in the main clinker phases offers a promising approach to improve both reactivity and grindability of clinkers. Thus, monitoring the chemistry of the phases may become part of the quality control at the cement plants, along with the usual measurements of the abundance of the mineralogical phases (quantitative X-ray diffraction) and the bulk chemistry (X-ray fluorescence). This paper presents a new method to assess these three complementary quantities with a single experiment. The method is based on electron microprobe spot analyses, performed over a grid located onmore » a representative surface of the sample and interpreted with advanced statistical tools. This paper describes the method and the experimental program performed on industrial clinkers to establish the accuracy in comparison to conventional methods. -- Highlights: •A new method of clinker characterization •Combination of electron probe technique with cluster analysis •Simultaneous assessment of phase abundance, composition and bulk chemistry •Experimental validation performed on industrial clinkers.« less

  5. Detection and quantification of cocaine and benzoylecgonine in meconium using solid phase extraction and UPLC/MS/MS.

    PubMed

    Gunn, Josh; Kriger, Scott; Terrell, Andrea R

    2010-01-01

    The simultaneous determination and quantification of cocaine and its major metabolite, benzoylecgonine, in meconium using UPLC-MS/MS is described. Ultra-performance liquid chromatography (UPLC) is an emerging analytical technique which draws upon the principles of chromatography to run separations at higher flow rates for increased speed, while simultaneously achieving superior resolution and sensitivity. Extraction of cocaine and benzoylecgonine from the homogenized meconium matrix was achieved with a preliminary protein precipitation or protein 'crash' employing cold acetonitrile, followed by a mixed mode solid phase extraction (SPE). Following elution from the SPE cartridge, eluents were dried down under nitrogen, reconstituted in 200 microL of DI water:acetonitrile (ACN) (75:25), and injected onto the UPLC/MS/MS for analysis. The increased speed and separation efficiency afforded by UPLC, allowed for the separation and subsequent quantification of both analytes in less than 2 min. Analytes were quantified using multiple reaction monitoring (MRM) and six-point calibration curves constructed in negative blood. Limits of detection for both analytes were 3 ng/g and the lower limit of quantitation (LLOQ) was 30 ng/g.

  6. [Evaluation of an automated pH-monitor and its logic of calculation].

    PubMed

    Ducrotté, P; Hubin, M; Xin, H; Roussignol, C; Denis, P

    1990-01-01

    The aim of this study was to compare the results of 3-hour postprandial esophageal pH recordings obtained simultaneously from a standard Beckmann pH recorder and a commercially available fully automated pH recording device, "pH 60" in 30 subjects. Both apparatuses were connected to the same pH probe and to a unique chart recorder to obtain simultaneous pH graphic tracings. The percentage of time between each pH level below pH 5, the percentage of time with pH less than 4 and Kaye's score were determined hourly and for the overall recording time. The pH graphic traces in both apparatuses were strictly identical demonstrating the accuracy of the analog-to-digital converter and the memory module to record pH changes. Moreover, we found a significant correlation (p less than 0.01) and a good overall agreement for all compared parameters between manual and computerized analysis. This study documents that the commercially available ambulatory esophageal pH instrument studied produces accurate data for the diagnosis of gastroesophageal reflux.

  7. [Simultaneous determination of nine preservatives in fruits using gas chromatography-mass spectrometry].

    PubMed

    Peng, Shunü; Wang, Qiuquan; Fang, Lanlan; Guo, Shanyong; Zeng, Zhouhua; Lin, Zhuguang

    2014-01-01

    A gas chromatography-mass spectrometry (GC-MS) method was established for the simultaneous determination of nine typical preservatives (pyrimethanil, chlorothalonil, chlorpyrifos, triadimefon, thiabendazole, imazalil, myclobutanil, iprodione, prochloraz) in fruits. The fruit samples were subjected to ultrasonic extraction with hexane/ethyl acetate (1/1, v/v), and followed by purification using diatomite column chromatography with hexane/ethyl acetate (1/3, v/v) eluant. Qualitative and quantitative analysis of the nine preservatives were performed on the GC-MS at full-scan (SCAN) and selected ion monitoring (SIM) modes, in which triphenylphosphate was used as the internal standard. The detection limits obtained for the nine preservatives were ranged from 0.10 microg/kg to 2.16 microg/kg. The average recoveries were in the range of 75.3% to 128% at the spiked levels of 50, 100 and 200 microg/kg with the relative standard deviations (RSDs) of 1.57% to 11.6% (n = 5). The results showed that the developed method is sensitive and accurate for the determination of the nine preservatives in fruits.

  8. Electrochemical camera chip for simultaneous imaging of multiple metabolites in biofilms

    PubMed Central

    Bellin, Daniel L.; Sakhtah, Hassan; Zhang, Yihan; Price-Whelan, Alexa; Dietrich, Lars E. P.; Shepard, Kenneth L.

    2016-01-01

    Monitoring spatial distribution of metabolites in multicellular structures can enhance understanding of the biochemical processes and regulation involved in cellular community development. Here we report on an electrochemical camera chip capable of simultaneous spatial imaging of multiple redox-active phenazine metabolites produced by Pseudomonas aeruginosa PA14 colony biofilms. The chip features an 8 mm × 8 mm array of 1,824 electrodes multiplexed to 38 parallel output channels. Using this chip, we demonstrate potential-sweep-based electrochemical imaging of whole-biofilms at measurement rates in excess of 0.2 s per electrode. Analysis of mutants with various capacities for phenazine production reveals distribution of phenazine-1-carboxylic acid (PCA) throughout the colony, with 5-methylphenazine-1-carboxylic acid (5-MCA) and pyocyanin (PYO) localized to the colony edge. Anaerobic growth on nitrate confirms the O2-dependence of PYO production and indicates an effect of O2 availability on 5-MCA synthesis. This integrated-circuit-based technique promises wide applicability in detecting redox-active species from diverse biological samples. PMID:26813638

  9. Microrheology: Structural evolution under static and dynamic conditions by simultaneous analysis of confocal microscopy and diffusing wave spectroscopy

    NASA Astrophysics Data System (ADS)

    Nicolas, Yves; Paques, Marcel; Knaebel, Alexandra; Steyer, Alain; Munch, Jean-Pierre; Blijdenstein, Theo B. J.; van Aken, George A.

    2003-08-01

    An oscillatory shear configuration was developed to improve understanding of structural evolution during deformation. It combines an inverted confocal scanning laser microscope (CSLM) and a special sample holder that can apply to the sample specific deformation: oscillatory shear or steady strain. In this configuration, a zero-velocity plane is created in the sample by moving two plates in opposite directions, thereby providing stable observation conditions of the structural behavior under deformation. The configuration also includes diffusion wave spectroscopy (DWS) to monitor the network properties via particle mobility under static and dynamic conditions. CSLM and DWS can be performed simultaneously and three-dimensional images can be obtained under static conditions. This configuration is mainly used to study mechanistic phenomena like particle interaction, aggregation, gelation and network disintegration, interactions at interfaces under static and dynamic conditions in semisolid food materials (desserts, dressings, sauces, dairy products) and in nonfood materials (mineral emulsions, etc.). Preliminary data obtained with this new oscillatory shear configuration are described that demonstrate their capabilities and the potential contribution to other areas of application also.

  10. Automatic online and real-time tumour motion monitoring during stereotactic liver treatments on a conventional linac by combined optical and sparse monoscopic imaging with kilovoltage x-rays (COSMIK)

    NASA Astrophysics Data System (ADS)

    Bertholet, Jenny; Toftegaard, Jakob; Hansen, Rune; Worm, Esben S.; Wan, Hanlin; Parikh, Parag J.; Weber, Britta; Høyer, Morten; Poulsen, Per R.

    2018-03-01

    The purpose of this study was to develop, validate and clinically demonstrate fully automatic tumour motion monitoring on a conventional linear accelerator by combined optical and sparse monoscopic imaging with kilovoltage x-rays (COSMIK). COSMIK combines auto-segmentation of implanted fiducial markers in cone-beam computed tomography (CBCT) projections and intra-treatment kV images with simultaneous streaming of an external motion signal. A pre-treatment CBCT is acquired with simultaneous recording of the motion of an external marker block on the abdomen. The 3-dimensional (3D) marker motion during the CBCT is estimated from the auto-segmented positions in the projections and used to optimize an external correlation model (ECM) of internal motion as a function of external motion. During treatment, the ECM estimates the internal motion from the external motion at 20 Hz. KV images are acquired every 3 s, auto-segmented, and used to update the ECM for baseline shifts between internal and external motion. The COSMIK method was validated using Calypso-recorded internal tumour motion with simultaneous camera-recorded external motion for 15 liver stereotactic body radiotherapy (SBRT) patients. The validation included phantom experiments and simulations hereof for 12 fractions and further simulations for 42 fractions. The simulations compared the accuracy of COSMIK with ECM-based monitoring without model updates and with model updates based on stereoscopic imaging as well as continuous kilovoltage intrafraction monitoring (KIM) at 10 Hz without an external signal. Clinical real-time tumour motion monitoring with COSMIK was performed offline for 14 liver SBRT patients (41 fractions) and online for one patient (two fractions). The mean 3D root-mean-square error for the four monitoring methods was 1.61 mm (COSMIK), 2.31 mm (ECM without updates), 1.49 mm (ECM with stereoscopic updates) and 0.75 mm (KIM). COSMIK is the first combined kV/optical real-time motion monitoring method used clinically online on a conventional accelerator. COSMIK gives less imaging dose than KIM and is in addition applicable when the kV imager cannot be deployed such as during non-coplanar fields.

  11. Simultaneous determination of three anticonvulsants using hydrophilic interaction LC-MS.

    PubMed

    Oertel, Reinhard; Arenz, Norman; Pietsch, Jörg; Kirch, Wilhelm

    2009-01-01

    A specific and automated method was developed to quantify the anticonvulsants gabapentin, pregabalin and vigabatrin simultaneously in human serum. Samples were prepared with a protein precipitation. The hydrophilic interaction chromatography (HILIC) with a mobile phase gradient was used to divide off ions of the matrix and for separation of the analytes. Four different HILIC-columns and two different column temperatures were tested. The Tosoh-Amid column gave the best results: single small peaks. The anticonvulsants were detected in the multiple reaction monitoring mode (MRM) with ESI-MS-MS. Using a volume of 100 microL biological sample the lowest point of the standard curve, i.e. the lower LOQs were 312 ng/mL. The described HILIC-MS-MS method is suitable for therapeutic drug monitoring and for clinical and pharmcokinetical investigations of the anticonvulsives.

  12. Rapid and sensitive method for simultaneous determination of first-line anti-tuberculosis drugs in human plasma by HPLC-MS/MS: Application to therapeutic drug monitoring.

    PubMed

    Gao, Shouhong; Wang, Zhipeng; Xie, Xinfang; You, Chunhua; Yang, Yang; Xi, Yanhai; Chen, Wansheng

    2018-03-01

    First-line anti-tuberculosis drugs are playing vital roles for curbing rapid spread of tuberculosis. Multidrug therapies are commonly applied in clinical to achieve better treatment outcomes. However, drug resistance and adverse reactions come along with this therapies and therapeutic drug monitoring is a feasible way to precaution them. For this reasons, a simple and sensitive method based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) and single protein precipitation was developed and validated for simultaneously quantifying of pyrazinamide, isoniazid, ethambutol, streptomycin and rifampicin in human plasma. Optimized chromatographic separation was achieved on a ZORBAX SB-C 18 column with heptafluorobutyric acid, an ion-pair reagent, in the mobile phase at a flow rate of 0.3 mL/min. The mass detection was achieved using electrospray ionization in the positive ion mode with a multiple reaction monitoring mode. The lower limit of quantification (LLOQ) and dynamic range of pyrazinamide, isoniazid, ethambutol, streptomycin and rifampicin were 200-4000 ng/mL, 80-2000 ng/mL, 0.2-1000 ng/mL, 2000-200000 ng/mL and 200-4000 ng/mL, respectively. The Inter-day and intra-day accuracy and precision were within ±15.0% and less than 15%. The method had been successfully applied to simultaneous determination of four first-line Anti-tuberculosis drugs in plasma from tuberculosis patients. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Simultaneous Monitoring of X-Ray and Radio Variability in Sagittarius A*

    NASA Astrophysics Data System (ADS)

    Capellupo, Daniel M.; Haggard, Daryl; Choux, Nicolas; Baganoff, Fred; Bower, Geoffrey C.; Cotton, Bill; Degenaar, Nathalie; Dexter, Jason; Falcke, Heino; Fragile, P. Chris; Heinke, Craig O.; Law, Casey J.; Markoff, Sera; Neilsen, Joey; Ponti, Gabriele; Rea, Nanda; Yusef-Zadeh, Farhad

    2017-08-01

    Monitoring of Sagittarius A* from X-ray to radio wavelengths has revealed structured variability—including X-ray flares—but it is challenging to establish correlations between them. Most studies have focused on variability in the X-ray and infrared, where variations are often simultaneous, and because long time series at submillimeter and radio wavelengths are limited. Previous work on submillimeter and radio variability hints at a lag between X-ray flares and their candidate submillimeter or radio counterparts, with the long wavelength data lagging the X-ray. However, there is only one published time lag between an X-ray flare and a possible radio counterpart. Here we report nine contemporaneous X-ray and radio observations of Sgr A*. We detect significant radio variability peaking ≳ 176 minutes after the brightest X-ray flare ever detected from Sgr A*. We also report other potentially associated X-ray and radio variability, with the radio peaks appearing ≲ 80 minutes after these weaker X-ray flares. Taken at face value, these results suggest that stronger X-ray flares lead to longer time lags in the radio. However, we also test the possibility that the variability at X-ray and radio wavelengths is not temporally correlated. We cross-correlate data from mismatched X-ray and radio epochs and obtain comparable correlations to the matched data. Hence, we find no overall statistical evidence that X-ray flares and radio variability are correlated, underscoring a need for more simultaneous, long duration X-ray-radio monitoring of Sgr A*.

  14. Microsurgical laser Doppler probe for simultaneous intraoperative monitoring of cochlear blood flow and electrocochleography from the round window

    NASA Astrophysics Data System (ADS)

    Abiy, Lidet; Telischi, Fred; Parel, Jean-Marie A.; Manns, Fabrice; Saettele, Ralph; Morawski, Krzysztof; Ozdamar, Ozcan; Borgos, John; Delgado, Rafael; Miskiel, Edward; Yavuz, Erdem

    2003-06-01

    The aim of this project is the development of a microsurgical laser Doppler (LD) probe that simultaneously monitors blood flow and Electrocochleography (ECochG) from the round window of the ear. The device will prevent neurosensory hearing loss during acoustic neuroma surgery by preventing damage to the internal auditory nerve and to the cochlear blood flow supply. A commercially available 0.5 mm diameter Laser-Doppler velocimetry probe (LaserFlo, Vasamedics) was modified to integrate an ECochG electrode. A tube for suction and irrigation was incorporated into a sheath of the probe shaft, to facilitate cleaning of the round window (RW) and allow drug delivery to the round window membrane. The prototype microprobe was calibrated on a single vessel model and tested in vivo in a rabbit model. Preliminary results indicate that the microprobe was able to measure changes in cochlear blood flow (CBF) and ECochG potentials from the round window of rabbits in vivo. The microprobe is suitable for monitoring cochlear blood flow and auditory cochlear potentials during human surgery.

  15. Unobtrusive measurement of indoor energy expenditure using an infrared sensor-based activity monitoring system.

    PubMed

    Hwang, Bosun; Han, Jonghee; Choi, Jong Min; Park, Kwang Suk

    2008-11-01

    The purpose of this study was to develop an unobtrusive energy expenditure (EE) measurement system using an infrared (IR) sensor-based activity monitoring system to measure indoor activities and to estimate individual quantitative EE. IR-sensor activation counts were measured with a Bluetooth-based monitoring system and the standard EE was calculated using an established regression equation. Ten male subjects participated in the experiment and three different EE measurement systems (gas analyzer, accelerometer, IR sensor) were used simultaneously in order to determine the regression equation and evaluate the performance. As a standard measurement, oxygen consumption was simultaneously measured by a portable metabolic system (Metamax 3X, Cortex, Germany). A single room experiment was performed to develop a regression model of the standard EE measurement from the proposed IR sensor-based measurement system. In addition, correlation and regression analyses were done to compare the performance of the IR system with that of the Actigraph system. We determined that our proposed IR-based EE measurement system shows a similar correlation to the Actigraph system with the standard measurement system.

  16. Detection of Gelatin Adulteration in Traditional Chinese Medicine: Analysis of Deer-Horn Glue by Rapid-Resolution Liquid Chromatography-Triple Quadrupole Mass Spectrometry

    PubMed Central

    Chen, Jia; Cheng, Xian-Long; Wei, Feng; Zhang, Qian-Qian; Li, Ming-Hua; Ma, Shuang-Cheng

    2015-01-01

    Simultaneous identification of donkey-hide gelatin and bovine-hide gelatin in deer-horn glue was established by rapid-resolution liquid chromatography-triple quadrupole mass spectrometry. Water containing 1% NH4HCO3 was used for sample dissolution and trypsin was used for hydrolysis of the gelatins. After separation by a SB-C18 reversed-phase analytical column, collagen marker peptides were detected by mass spectrometry in positive electrospray ionization mode with multiple reaction monitoring. The method was specific, precise and reliable, and suitable for detection of adulterants derived from donkey-hide gelatin and bovine-hide gelatin in deer-horn glue. PMID:26504613

  17. Detection of collaborative activity with Kinect depth cameras.

    PubMed

    Sevrin, Loic; Noury, Norbert; Abouchi, Nacer; Jumel, Fabrice; Massot, Bertrand; Saraydaryan, Jacques

    2016-08-01

    The health status of elderly subjects is highly correlated to their activities together with their social interactions. Thus, the long term monitoring in home of their health status, shall also address the analysis of collaborative activities. This paper proposes a preliminary approach of such a system which can detect the simultaneous presence of several subjects in a common area using Kinect depth cameras. Most areas in home being dedicated to specific tasks, the localization enables the classification of tasks, whether collaborative or not. A scenario of a 24 hours day shrunk into 24 minutes was used to validate our approach. It pointed out the need of artifacts removal to reach high specificity and good sensitivity.

  18. The 2010 ILSO-ISRU Field Test at Mauna Kea, Hawaii: Results from the Miniaturised Mossbauer Spectrometers Mimos II and Mimos IIA

    NASA Technical Reports Server (NTRS)

    Klingelhoefer, G.; Morris, R. V.; Blumers, M.; Bernhardt, B.; Graff, T.

    2011-01-01

    For the advanced Moessbauer instrument MIMOS IIA, the new detector technologies and electronic components increase sensitivity and performance significantly. In combination with the high energy resolution of the SDD it is possible to perform X-ray fluorescence analysis simultaneously to Moessbauer spectroscopy. In addition to the Fe-mineralogy, information on the sample's elemental composition will be gathered. The ISRU 2010 field campaign demonstrated that in-situ Moessbauer spectroscopy is an effective tool for both science and feedstock exploration and process monitoring. Engineering tests showed that a compact nickel metal hydride battery provided sufficient power for over 12 hr of continuous operation for the MIMOS instruments.

  19. Spatiotemporal evolution of thin liquid films during impact of water bubbles on glass on a micrometer to nanometer scale.

    PubMed

    Hendrix, Maurice H W; Manica, Rogerio; Klaseboer, Evert; Chan, Derek Y C; Ohl, Claus-Dieter

    2012-06-15

    Collisions between millimeter-size bubbles in water against a glass plate are studied using high-speed video. Bubble trajectory and shape are tracked simultaneously with laser interferometry between the glass and bubble surfaces that monitors spatial-temporal evolution of the trapped water film. Initial bubble bounces and the final attachment of the bubble to the surface have been quantified. While the global Reynolds number is large (∼10(2)), the film Reynolds number remains small and permits analysis with lubrication theory with tangentially immobile boundary condition at the air-water interface. Accurate predictions of dimple formation and subsequent film drainage are obtained.

  20. [Simultaneous determination of 11 bisphenols in plastic bottled drinking water by ultra performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Gou, Xinlei; Gao, Xia; Hu, Guanghui; Chi, Haitao; Le, Shengfeng; Wang, Wei; Liu, Weili

    2014-09-01

    A sensitive method was developed for the simultaneous determination of 11 bisphenols in plastic bottled drinking water by ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The samples were freeze-dried under vacuum and then dissolved with methanol. The separation was performed on a UPLC BEH C18 column (100 mm x 2.1 mm, 1.7 μm) by using 0.1% (v/v) NH3 · H2O and methanol as mobile phases with gradient elution at a flow rate of 0.2 mL/min. The electrospray ionization (ESI) source in negative ion mode was used for the analysis of the 11 bisphenols in the multiple reaction monitoring (MRM) mode. The results verified that the standard curves for the 11 bisphenols were obtained with good correlation coefficients (R2) > 0.997 in their concentration ranges. The limits of detection (LOD, S/N = 3) for the 11 bisphenols were in the range of 0.01-1.00 μg/L. The mean recoveries for the 11 bisphenols at three spiked levels (low, middle, high) were 75.3%-102.1% with the relative standard deviations of 1.5%-8.9%. Seven plastic bottled drinking water samples were tested, and no bisphenol was found. The method is accurate, simple, rapid and feasible for the simultaneous determination of bisphenols in plastic bottled drinking water.

  1. Development of a LC-MS/MS method for the simultaneous screening of seven water-soluble vitamins in processing semi-coarse wheat flour products.

    PubMed

    Nurit, Eric; Lyan, Bernard; Piquet, Agnès; Branlard, Gérard; Pujos-Guillot, Estelle

    2015-05-01

    Wheat is the second largest crop cultivated around the world and constitutes a major part of the daily diet in Europe. It is therefore important to determine the content of micronutrient in wheat and wheat-based food products to define the contribution of wheat-based foods to the nutrition of the consumers. The aim of the present work was to develop a simple and rapid method based on liquid chromatography tandem mass spectrometry (LC-MS/MS) for the simultaneous determination of seven water-soluble vitamins in various wheat-based food materials. The vitamins present in the test material were separated in less than 15 min by using a reverse-phase C18 column, and analyzed by positive ion electrospray selected reaction monitoring MS/MS. The MS response for all the vitamins was linear over the working range (0.05 to 9 μg/mL) with correlation coefficients ranging between 0.991 and 1. Limits of quantification in the different food materials ranged from 0.09 to 3.5 μg/g. Intra-day and inter-day precision were found satisfactory. The developed method was applied for the simultaneous analysis of the water-soluble vitamin natural content of different semi-coarse wheat flours and in their corresponding baking products.

  2. Software design of a remote real-time ECG monitoring system

    NASA Astrophysics Data System (ADS)

    Yu, Chengbo; Tao, Hongyan

    2005-12-01

    Heart disease is one of the main diseases that threaten the health and lives of human beings. At present, the normal remote ECG monitoring system has the disadvantages of a short testing distance and limitation of monitoring lines. Because of accident and paroxysmal disease, ECG monitoring has extended from the hospital to the family. Therefore, remote ECG monitoring through the Internet has the actual value and significance. The principle and design method of software of the remote dynamic ECG monitor was presented and discussed. The monitoring software is programmed with Delphi software based on client-sever interactive mode. The application program of the system, which makes use of multithreading technology, is shown to perform in an excellent manner. The program includes remote link users and ECG processing, i.e. ECG data's receiving, real-time displaying, recording and replaying. The system can connect many clients simultaneously and perform real-time monitoring to patients.

  3. Errors Recruit both Cognitive and Emotional Monitoring Systems: Simultaneous Intracranial Recordings in the Dorsal Anterior Cingulate Gyrus and Amygdala Combined with fMRI

    ERIC Educational Resources Information Center

    Pourtois, Gilles; Vocat, Roland; N'Diaye, Karim; Spinelli, Laurent; Seeck, Margitta; Vuilleumier, Patrik

    2010-01-01

    We studied error monitoring in a human patient with unique implantation of depth electrodes in both the left dorsal cingulate gyrus and medial temporal lobe prior to surgery. The patient performed a speeded go/nogo task and made a substantial number of commission errors (false alarms). As predicted, intracranial Local Field Potentials (iLFPs) in…

  4. Simultaneous determination of 18 abused opioids and metabolites in human hair using LC-MS/MS and illegal opioids abuse proven by hair analysis.

    PubMed

    Kim, Jihyun; Ji, Dajeong; Kang, Soyoung; Park, Meejung; Yang, Wonkyung; Kim, Eunmi; Choi, Hwakyung; Lee, Sooyeun

    2014-02-01

    Natural and synthetic opioids have efficient analgesic activity but can also be addictive. Thus, the determination of opioids and their metabolites in biological specimens is of interest in clinical and forensic toxicology laboratories. The analysis of drugs in hair provides valuable information on previous chronic drug use and has been successfully applied to the diagnosis of drug abuse, tolerance, compliance and gestational drug exposure. Despite the abuse of prescription opioids along with heroin and other illegal opiates, few studies have been conducted on the simultaneous determination of the broad range of opioids covering those drugs in hair. In the present study, an analytical method for the simultaneous detection in hair of 18 opioids and metabolites considered to have a high abuse risk based on the results of urine drug screening was established and validated using liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the purpose of clinical and forensic applications. The drugs and metabolites were extracted from hair using methanol and analyzed using LC-MS/MS. The validation results proved that the method was selective, accurate and precise with acceptable linearity within calibration ranges. No significant variation was observed by different sources of matrices. The limits of detection and the limits of quantification ranged from 0.05 to 0.25ng/10mg hair and from 0.05 to 0.5ng/10mg hair, respectively. The developed method was successfully applied to 15 hair samples from opioids users. This method will be very useful for monitoring the inappropriate use of opioid drugs. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Multi-objective optimization strategy based on desirability functions used for electrophoratic separation and quantification of rosiglitazone and glimepiride in plasma and formulations.

    PubMed

    Hefnawy, Mohamed M; Sultan, Maha A; Al-Johar, Haya I; Kassem, Mohamed G; Aboul-Enein, Hassan Y

    2012-01-01

    Multiple response simultaneous optimization employing Derringer's desirability function was used for the development of a capillary electrophoresis method for the simultaneous determination of rosiglitazone (RSG) and glimepiride (GLM) in plasma and formulations. Twenty experiments, taking the two resolutions, the analysis time, and the capillary current as the responses with three important factors--buffer morality, volte and column temperature--were used to design mathematical models. The experimental responses were fitted into a second order polynomial and the six responses were simultaneously optimized to predict the optimum conditions for the effective separation of the studied compounds. The separation was carried out by using capillary zone electrophoresis (CZE) with a silica capillary column and diode array detector at 210 nm. The optimum assay conditions were 52 mmol l⁻¹ phosphate buffer, pH 7, and voltage of 22 kV at 29 °C. The method showed good agreement between the experimental data and predictive value throughout the studied parameter space. The assay limit of detection was 0.02 µg ml⁻¹ and the effective working range at relative standard deviation (RSD) of ≤ 5% was 0.05-16 µg ml⁻¹ (r = 0.999) for both drugs. Analytical recoveries of the studied drugs from spiked plasma were 97.2-101.9 ± 0.31-3.0%. The precision of the assay was satisfactory; RSD was 1.07 and 1.14 for intra- and inter-assay precision, respectively. The proposed method has a great value in routine analysis of RSG and GLM for its therapeutic monitoring and pharmacokinetic studies. Copyright © 2011 John Wiley & Sons, Ltd.

  6. Simultaneous measurements of bulk moduli and particle dynamics in a sheared colloidal glass

    NASA Astrophysics Data System (ADS)

    Massa, Michael V.; Eisenmann, Christoph; Kim, Chanjoong; Weitz, David A.

    2007-03-01

    We present a novel study of glassy colloidal systems, using a stress-controlled rheometer in conjunction with a confocal microscope. This experimental setup combines the measurement of bulk moduli, using conventional rheology, with the ability to track the motion of individual particles, through confocal microscopy techniques. We explore the response of the system to applied shear, by simultaneously monitoring the macroscopic relaxation and microscopic particle dynamics, under conditions from the quiescent glass to a shear-melted liquid.

  7. Initial Evaluation of Signal-Based Bayesian Monitoring

    NASA Astrophysics Data System (ADS)

    Moore, D.; Russell, S.

    2016-12-01

    We present SIGVISA (Signal-based Vertically Integrated Seismic Analysis), a next-generation system for global seismic monitoring through Bayesian inference on seismic signals. Traditional seismic monitoring systems rely on discrete detections produced by station processing software, discarding significant information present in the original recorded signal. By modeling signals directly, our forward model is able to incorporate a rich representation of the physics underlying the signal generation process, including source mechanisms, wave propagation, and station response. This allows inference in the model to recover the qualitative behavior of geophysical methods including waveform matching and double-differencing, all as part of a unified Bayesian monitoring system that simultaneously detects and locates events from a network of stations. We report results from an evaluation of SIGVISA monitoring the western United States for a two-week period following the magnitude 6.0 event in Wells, NV in February 2008. During this period, SIGVISA detects more than twice as many events as NETVISA, and three times as many as SEL3, while operating at the same precision; at lower precisions it detects up to five times as many events as SEL3. At the same time, signal-based monitoring reduces mean location errors by a factor of four relative to detection-based systems. We provide evidence that, given only IMS data, SIGVISA detects events that are missed by regional monitoring networks, indicating that our evaluations may even underestimate its performance. Finally, SIGVISA matches or exceeds the detection rates of existing systems for de novo events - events with no nearby historical seismicity - and detects through automated processing a number of such events missed even by the human analysts generating the LEB.

  8. Comparison of home sleep apnea testing versus laboratory polysomnography for the diagnosis of obstructive sleep apnea in children.

    PubMed

    Scalzitti, Nicholas; Hansen, Shana; Maturo, Stephen; Lospinoso, Joshua; O'Connor, Peter

    2017-09-01

    Obstructive sleep apnea (OSA) affects 1-5% of pediatric patients. Laboratory polysomnography is expensive, not always available, and is inconvenient for patients. Our study investigates the diagnostic ability of an unattended ambulatory monitor for the diagnosis of pediatric OSA. A prospective study was conducted in children, ages 2-17. Subjects completed in-lab polysomnography simultaneously with ambulatory monitoring. Caregivers attempted home studies on two subsequent nights to compare the home monitor and the laboratory polysomnogram (PSG). Thirty-three subjects completed simultaneous laboratory polysomnogram with portable monitoring. Twenty patients completed home studies, with 16 completing 2 nights of monitoring. The measurement of AHI by the portable monitor was different than that obtained by the PSG with statistical significance for the comparisons of PSG vs. In-Lab (p = 0.0026), PSG vs. Home 1 (p = 0.033), and PSG vs. Home 2 (p = 0.033). The sensitivity of the portable monitor for diagnosing OSA was best for the In-lab use at 81%, but only 69% and 70% for the uses at home on the 2 nights respectively. Interestingly, the comparison of AHI and lowest oxygen saturation measurements from the home sleep test in children age 6 and older did not differ significantly from the PSG. This pilot study demonstrated differences between home sleep testing and in-lab polysomnography for the diagnosis of pediatric sleep apnea. These differences were predominantly found to exist in younger children. Larger prospective studies are needed prior to widespread use, but home studies may alleviate issues of access to care and higher costs of laboratory polysomnography. Published by Elsevier B.V.

  9. End-Use Load and Conservation Assessment Program : Co-Instrumentation Test of Two Microcomputer-Based Energy Monitoring Systems.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fishbaugher, M. J.

    1985-05-01

    The decreasing cost of microcomputers along with improvements in power metering circuitry have changed the way in which electrical energy use is monitored. Although utilities still rely on kilowatt-hour (kWh) meters for billing purposes, a microcomputer-based monitoring system is used when greater temporal and end-use resolution is desired. Because these types of monitoring systems will be used increasingly in large-scale conservation and end-use studies, it is important that their performance be analyzed to determine their accuracy. A co-instrumentation test was devised in which two such microcomputer-based monitoring systems made simultaneous measurements of electrical end-uses in two commercial buildings. The analysismore » of the co-instrumentation data aids in the evaluation of microcomputer-based monitoring systems used for end-use measurements. Separate and independent data loggers were used to measure the same loads simultaneously. In addition to these two systems, a utility billing meter measured the total energy use in each building during the co-instrumentation test. The utility's meters provided a relatively accurate standard by which the performance of both loggers could be judged. The comparison between the SCL and PNL microcomputer-based loggers has shown that power measurement techniques directly affect system performance. The co-instrumentation test has shown that there are certain standards that a monitoring system must meet if it is to perform well. First, it is essential to calibrate a microcomputer-based logger against a known standard load before the system is installed. Second, a microcomputer-based system must have some way of accounting for power factors. Recent advances in power metering circuitry have made it relatively easy to apply these power factors automatically in real time.« less

  10. Mid-IR spectroscopic instrumentation for point-of-care diagnosis using a hollow silica waveguide gas cell

    NASA Astrophysics Data System (ADS)

    Francis, Daniel; Hodgkinson, Jane; Walton, Christopher; Sizer, Jeremy; Black, Paul; Livingstone, Beth; Fowler, Dawn P.; Patel, Mitesh K.; Tatam, Ralph P.

    2017-02-01

    Laser spectroscopy provides the basis of instrumentation developed for the diagnosis of infectious disease, via quantification of organic biomarkers that are produced by associated bacteria. The technology is centred on a multichannel pulsed quantum cascade laser system that allows multiple lasers with different wavelengths to be used simultaneously, each selected to monitor a different diagnostic biomarker. The instrument also utilizes a hollow silica waveguide (HSW) gas cell which has a very high ratio of interaction pathlength to internal volume. This allows sensitive detection of low volume gas species from small volume biological samples. The spectroscopic performance of a range of HSW gas cells with different lengths and bore diameters has been assessed using methane as a test gas and a best-case limit of detection of 0.26 ppm was determined. The response time of this cell was measured as a 1,000 sccm flow of methane passed through it and was found to be 0.75 s. These results are compared with those obtained using a multi-pass Herriot cell. A prototype instrument has been built and approved for clinical trials for detection of lung infection in acute-care patients via analysis of ventilator breath. Demonstration of the instrument for headspace gas analysis is made by monitoring the methane emission from bovine faeces. The manufacture of a hospital-ready device for monitoring biomarkers of infection in the exhaled breath of intensive care ventilator patients is also presented.

  11. Monitoring Streambed Scour/Deposition Under Nonideal Temperature Signal and Flood Conditions

    NASA Astrophysics Data System (ADS)

    DeWeese, Timothy; Tonina, Daniele; Luce, Charles

    2017-12-01

    Streambed erosion and deposition are fundamental geomorphic processes in riverbeds, and monitoring their evolution is important for ecological system management and in-stream infrastructure stability. Previous research showed proof of concept that analysis of paired temperature signals of stream and pore waters can simultaneously provide monitoring scour and deposition, stream sediment thermal regime, and seepage velocity information. However, it did not address challenges often associated with natural systems, including nonideal temperature variations (low-amplitude, nonsinusoidal signal, and vertical thermal gradients) and natural flooding conditions on monitoring scour and deposition processes over time. Here we addressed this knowledge gap by testing the proposed thermal scour-deposition chain (TSDC) methodology, with laboratory experiments to test the impact of nonideal temperature signals under a range of seepage velocities and with a field application during a pulse flood. Both analyses showed excellent match between surveyed and temperature-derived bed elevation changes even under very low temperature signal amplitudes (less than 1°C), nonideal signal shape (sawtooth shape), and strong and changing vertical thermal gradients (4°C/m). Root-mean-square errors on predicting the change in streambed elevations were comparable with the median grain size of the streambed sediment. Future research should focus on improved techniques for temperature signal phase and amplitude extractions, as well as TSDC applications over long periods spanning entire hydrographs.

  12. Ionosphere Scintillation at Low and High Latitudes (Modelling vs Measurement)

    NASA Astrophysics Data System (ADS)

    Béniguel, Yannick

    2016-04-01

    This paper will address the problem of scintillations characteristics, focusing on the parameters of interest for a navigation system. Those parameters are the probabilities of occurrence of simultaneous fading, the bubbles surface at IPP level, the cycle slips and the fades duration statistics. The scintillation characteristics obtained at low and high latitudes will be compared. These results correspond to the data analysis performed after the ESA Monitor ionosphere measurement campaign [1], [2]. A second aspect of the presentation will be the modelling aspect. It has been observed that the phase scintillation dominates at high latitudes while the intensity scintillation dominates at low latitudes. The way it can be reproduced and implemented in a propagation model (e.g. GISM model [3]) will be presented. Comparisons of measurements with results obtained by modelling will be presented on some typical scenarios. References [1] R. Prieto Cerdeira, Y. Beniguel, "The MONITOR project: architecture, data and products", Ionospheric Effects Symposium, Alexandria (Va), May 2011 [2] Y. Béniguel, R Orus-Perez , R. Prieto-Cerdeira , S. Schlueter , S. Scortan, A. Grosu "MONITOR 2: ionospheric monitoring network in support to SBAS and other GNSS and scientific purposes", IES Conference, Alexandria (Va), May 2015-05-22 [3] Y. Béniguel, P. Hamel, "A Global Ionosphere Scintillation Propagation Model for Equatorial Regions", Journal of Space Weather Space Climate, 1, (2011), doi: 10.1051/swsc/2011004

  13. Electrochemical noise measurements of sustained microbially influenced pitting corrosion in a laboratory flow loop system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, Y.; Frank, J.R.; St. Martin, E.J.

    Because of the chaotic nature of the corrosion process and the complexity of the electrochemical noise signals that are generated, there is no generally accepted method of measuring and interpreting these signals that allows the consistent detection and identification of sustained localized pitting (SLP) as compared to general corrosion. The authors have reexamined electrochemical noise analysis (ENA) of localized corrosion using different hardware, signal collection, and signal processing designs than those used in conventional ENA techniques. The new data acquisition system was designed to identify and monitor the progress of SLP by analyzing the power spectral density (PSD) of themore » trend of the corrosion current noise level (CNL) and potential noise level (PNL). Each CNL and PNL data point was calculated from the root-mean-square value of the ac components of current and potential fluctuation signals, which were measured simultaneously during a short time period. The PSD analysis results consistently demonstrated that the trends of PNL and CNL contain information that can be used to differentiate between SLP and general corrosion mechanisms. The degree of linear slope in the low-frequency portion of the PSD analysis was correlated with the SLP process. Laboratory metal coupons as well as commercial corrosion probes were tested to ensure the reproducibility and consistency of the results. The on-line monitoring capability of this new ENA method was evaluated in a bench-scale flow-loop system, which simulated microbially influenced corrosion (MIC) activity. The conditions in the test flow-loop system were controlled by the addition of microbes and different substrates to favor accelerated corrosion. The ENA results demonstrated that this in-situ corrosion monitoring system could effectively identify SLP corrosion associated with MIC, compared to a more uniform general corrosion mechanism. A reduction in SLP activity could be clearly detected by the ENA monitoring system when a corrosion inhibitor was added into one of the test loops during the corrosion testing.« less

  14. Electrochemical noise measurements of sustained microbially influenced pitting corrosion in a laboratory flow loop system.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, Y. J.

    Because of the chaotic nature of the corrosion process and the complexity of the electrochemical noise signals that are generated, there is no generally accepted method of measuring and interpreting these signals that allows the consistent detection and identification of sustained localized pitting (SLP) as compared to general corrosion. We have reexamined electrochemical noise analysis (ENA) of localized corrosion using different hardware, signal collection, and signal processing designs than those used in conventional ENA techniques. The new data acquisition system was designed to identify and monitor the progress of SLP by analyzing the power spectral density (PSD) of the trendmore » of the corrosion current noise level (CNL) and potential noise level (PNL). Each CNL and PNL data point was calculated from the root-mean- square value of the ac components of current and potential fluctuation signals, which were measured simultaneously during a short time period. The PSD analysis results consistently demonstrated that the trends of PNL and CNL contain information that can be used to differentiate between SLP and general corrosion mechanisms. The degree of linear slope in the low-frequency portion of the PSD analysis was correlated with the SLP process. Laboratory metal coupons as well as commercial corrosion probes were tested to ensure the reproducibility and consistency of the results. The on-line monitoring capability of this new ENA method was evaluated in a bench-scale flow-loop system, which simulated microbially influenced corrosion (MIC) activity. The conditions in the test flow-loop system were controlled by the addition of microbes and different substrates to favor accelerated corrosion. The ENA results demonstrated that this in-situ corrosion monitoring system could effectively identify SLP corrosion associated with MIC, compared to a more uniform general corrosion mechanism. A reduction in SLP activity could be clearly detected by the ENA monitoring system when a corrosion inhibitor was added into one of the test loops during the corrosion testing.« less

  15. Fluorescence Polarization and Fluctuation Analysis Monitors Subunit Proximity, Stoichiometry, and Protein Complex Hydrodynamics

    PubMed Central

    Nguyen, Tuan A.; Sarkar, Pabak; Veetil, Jithesh V.; Koushik, Srinagesh V.; Vogel, Steven S.

    2012-01-01

    Förster resonance energy transfer (FRET) microscopy is frequently used to study protein interactions and conformational changes in living cells. The utility of FRET is limited by false positive and negative signals. To overcome these limitations we have developed Fluorescence Polarization and Fluctuation Analysis (FPFA), a hybrid single-molecule based method combining time-resolved fluorescence anisotropy (homo-FRET) and fluorescence correlation spectroscopy. Using FPFA, homo-FRET (a 1–10 nm proximity gauge), brightness (a measure of the number of fluorescent subunits in a complex), and correlation time (an attribute sensitive to the mass and shape of a protein complex) can be simultaneously measured. These measurements together rigorously constrain the interpretation of FRET signals. Venus based control-constructs were used to validate FPFA. The utility of FPFA was demonstrated by measuring in living cells the number of subunits in the α-isoform of Venus-tagged calcium-calmodulin dependent protein kinase-II (CaMKIIα) holoenzyme. Brightness analysis revealed that the holoenzyme has, on average, 11.9±1.2 subunit, but values ranged from 10–14 in individual cells. Homo-FRET analysis simultaneously detected that catalytic domains were arranged as dimers in the dodecameric holoenzyme, and this paired organization was confirmed by quantitative hetero-FRET analysis. In freshly prepared cell homogenates FPFA detected only 10.2±1.3 subunits in the holoenzyme with values ranging from 9–12. Despite the reduction in subunit number, catalytic domains were still arranged as pairs in homogenates. Thus, FPFA suggests that while the absolute number of subunits in an auto-inhibited holoenzyme might vary from cell to cell, the organization of catalytic domains into pairs is preserved. PMID:22666486

  16. Lessons Learned From a Pilot RCT of Simultaneous Versus Delayed Initiation of Continuous Glucose Monitoring in Children and Adolescents With Type 1 Diabetes Starting Insulin Pump Therapy

    PubMed Central

    Olivier, Patricia; Huot, Celine; Richardson, Christine; Nakhla, Meranda; Romain, Judette

    2014-01-01

    Uncertainty remains about effectiveness of continuous glucose monitoring (CGM) in pediatric type 1 diabetes (T1D). Success with CGM is related to CGM adherence, which may relate to readiness to make the behavior changes required for effective use. We hypothesize that readiness for change will be greater at initiation of insulin pump therapy than in established pump users, and that this will predict CGM adherence. Our objective was to evaluate the feasibility of a randomized controlled trial (RCT) in children with established T1D comparing simultaneous pump and CGM initiation to standard pump therapy with delayed CGM initiation. We randomized participants to simultaneous pump and CGM initiation or to standard pump therapy with the option of adding CGM 4 months later. CGM adherence was tracked via web-based download and readiness for change assessed with the SOCRATES questionnaire. Of 41 eligible children, 20 agreed to participate; 15 subjects completed the study (7 males; baseline age 11.8 ± 4.0 years; T1D duration 2.7 ± 2.7 years; mean A1C 8.2 ± 0.8%). Six of 8 simultaneous group subjects used CGM > 60% of the time for 4 months compared to 1 of 7 delayed group subjects (P = .02). Using SOCRATES, we could assign 87-100% of subjects to a single motivation stage at baseline and 4 months. This pilot study demonstrates the feasibility of randomizing pump naïve children and adolescents with established T1D to simultaneous pump and CGM initiation versus standard pump therapy with delayed CGM initiation. Lessons from this pilot study were used to inform development of a full-scale multicenter RCT. PMID:24876616

  17. Ratio of sequential chromatograms for quantitative analysis and peak deconvolution: Application to standard addition method and process monitoring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Synovec, R.E.; Johnson, E.L.; Bahowick, T.J.

    1990-08-01

    This paper describes a new technique for data analysis in chromatography, based on taking the point-by-point ratio of sequential chromatograms that have been base line corrected. This ratio chromatogram provides a robust means for the identification and the quantitation of analytes. In addition, the appearance of an interferent is made highly visible, even when it coelutes with desired analytes. For quantitative analysis, the region of the ratio chromatogram corresponding to the pure elution of an analyte is identified and is used to calculate a ratio value equal to the ratio of concentrations of the analyte in sequential injections. For themore » ratio value calculation, a variance-weighted average is used, which compensates for the varying signal-to-noise ratio. This ratio value, or equivalently the percent change in concentration, is the basis of a chromatographic standard addition method and an algorithm to monitor analyte concentration in a process stream. In the case of overlapped peaks, a spiking procedure is used to calculate both the original concentration of an analyte and its signal contribution to the original chromatogram. Thus, quantitation and curve resolution may be performed simultaneously, without peak modeling or curve fitting. These concepts are demonstrated by using data from ion chromatography, but the technique should be applicable to all chromatographic techniques.« less

  18. Integrated Analysis and Tools for Land Subsidence Surveying and Monitoring: a Semi-Quantitative Approach

    NASA Astrophysics Data System (ADS)

    Mosconi, A.; Pozzoli, A.; Meroni, A.; Gagliano, S.

    2015-10-01

    This paper presents an integrated approach for land subsidence monitoring using measures coming from different sensors. Eni S.p.A., the main Italian oil and gas company, constantly surveys the land with all the state of the art and innovative techniques, and a method able to integrate the results is an important and actual topic. Nowadays the world is a multi-sensor platform, and measure integration is strictly necessary. Combining the different data sources should be done in a clever way, taking advantages from the best performances of each technique. An integrated analysis allows the interpretation of simultaneous temporal series of data, coming from different sources, and try to separate subsidence contributions. With this purpose Exelis VIS in collaboration with Eni S.p.A. customize PISAV (Permanent Interferometric Scatterometer Analysis and Visualization), an ENVI extension able to capitalize on and combine all the different data collected in the surveys. In this article are presented some significant examples to show the potential of this tool in oil and gas activity: a hydrocarbon storage field where the comparison between SAR and production volumes emphasise a correlation between the two measures in few steps; and a hydrocarbon production field with the Satellite Survey Unit (S.S.U.), where SAR, CGPS, piezometers and assestimeters measure in the same area at the same time, giving the opportunity to analyse data contextually. In the integrated analysis performed with PISAV not always a mathematical rigorous study is possible, and a semi-quantitative approach is the only method for results interpretation. As a result, in the first test case strong correlation between injected hydrocarbon volume and vertical displacement were highlighted; in the second one the integrated analysis has different advantages in monitoring the land subsidence: permits a first qualitative "differentiation" of the natural and anthropic component of subsidence, and also gives more reliability and coverage to each measurement, taking advantages from the strong points of each technique.

  19. Analysis of modeling cumulative noise from simultaneous flights volume 1 : analysis at four national parks

    DOT National Transportation Integrated Search

    2012-12-31

    This is the first of two volumes of the report on modeling cumulative noise from simultaneous flights. This volume includes: an overview of the time compression algorithms used to model simultaneous aircraft; revised summary of a preliminary study (w...

  20. Development and validation of an universal interface for compound-specific stable isotope analysis of chlorine (37Cl/35Cl) by GC-high-temperature conversion (HTC)-MS/IRMS.

    PubMed

    Renpenning, Julian; Hitzfeld, Kristina L; Gilevska, Tetyana; Nijenhuis, Ivonne; Gehre, Matthias; Richnow, Hans-Hermann

    2015-03-03

    A universal application of compound-specific isotope analysis of chlorine was thus far limited by the availability of suitable analysis techniques. In this study, gas chromatography in combination with a high-temperature conversion interface (GC-HTC), converting organic chlorine in the presence of H2 to gaseous HCl, was coupled to a dual-detection system, combining an ion trap mass spectrometer (MS) and isotope-ratio mass spectrometer (IRMS). The combination of the MS/IRMS detection enabled a detailed characterization, optimization, and online monitoring of the high-temperature conversion process via ion trap MS as well as a simultaneous chlorine isotope analysis by the IRMS. Using GC-HTC-MS/IRMS, chlorine isotope analysis at optimized conversion conditions resulted in very accurate isotope values (δ(37)Cl(SMOC)) for measured reference material with known isotope composition, including chlorinated ethylene, chloromethane, hexachlorocyclohexane, and trichloroacetic acids methyl ester. Respective detection limits were determined to be <15 nmol Cl on column with achieved precision of <0.3‰.

  1. Video surveillance captures student hand hygiene behavior, reactivity to observation, and peer influence in Kenyan primary schools.

    PubMed

    Pickering, Amy J; Blum, Annalise G; Breiman, Robert F; Ram, Pavani K; Davis, Jennifer

    2014-01-01

    In-person structured observation is considered the best approach for measuring hand hygiene behavior, yet is expensive, time consuming, and may alter behavior. Video surveillance could be a useful tool for objectively monitoring hand hygiene behavior if validated against current methods. Student hand cleaning behavior was monitored with video surveillance and in-person structured observation, both simultaneously and separately, at four primary schools in urban Kenya over a study period of 8 weeks. Video surveillance and in-person observation captured similar rates of hand cleaning (absolute difference <5%, p = 0.74). Video surveillance documented higher hand cleaning rates (71%) when at least one other person was present at the hand cleaning station, compared to when a student was alone (48%; rate ratio  = 1.14 [95% CI 1.01-1.28]). Students increased hand cleaning rates during simultaneous video and in-person monitoring as compared to single-method monitoring, suggesting reactivity to each method of monitoring. This trend was documented at schools receiving a handwashing with soap intervention, but not at schools receiving a sanitizer intervention. Video surveillance of hand hygiene behavior yields results comparable to in-person observation among schools in a resource-constrained setting. Video surveillance also has certain advantages over in-person observation, including rapid data processing and the capability to capture new behavioral insights. Peer influence can significantly improve student hand cleaning behavior and, when possible, should be exploited in the design and implementation of school hand hygiene programs.

  2. Performance Measurement, Visualization and Modeling of Parallel and Distributed Programs

    NASA Technical Reports Server (NTRS)

    Yan, Jerry C.; Sarukkai, Sekhar R.; Mehra, Pankaj; Lum, Henry, Jr. (Technical Monitor)

    1994-01-01

    This paper presents a methodology for debugging the performance of message-passing programs on both tightly coupled and loosely coupled distributed-memory machines. The AIMS (Automated Instrumentation and Monitoring System) toolkit, a suite of software tools for measurement and analysis of performance, is introduced and its application illustrated using several benchmark programs drawn from the field of computational fluid dynamics. AIMS includes (i) Xinstrument, a powerful source-code instrumentor, which supports both Fortran77 and C as well as a number of different message-passing libraries including Intel's NX Thinking Machines' CMMD, and PVM; (ii) Monitor, a library of timestamping and trace -collection routines that run on supercomputers (such as Intel's iPSC/860, Delta, and Paragon and Thinking Machines' CM5) as well as on networks of workstations (including Convex Cluster and SparcStations connected by a LAN); (iii) Visualization Kernel, a trace-animation facility that supports source-code clickback, simultaneous visualization of computation and communication patterns, as well as analysis of data movements; (iv) Statistics Kernel, an advanced profiling facility, that associates a variety of performance data with various syntactic components of a parallel program; (v) Index Kernel, a diagnostic tool that helps pinpoint performance bottlenecks through the use of abstract indices; (vi) Modeling Kernel, a facility for automated modeling of message-passing programs that supports both simulation -based and analytical approaches to performance prediction and scalability analysis; (vii) Intrusion Compensator, a utility for recovering true performance from observed performance by removing the overheads of monitoring and their effects on the communication pattern of the program; and (viii) Compatibility Tools, that convert AIMS-generated traces into formats used by other performance-visualization tools, such as ParaGraph, Pablo, and certain AVS/Explorer modules.

  3. Multimodal OCT for complex assessment of tumors response to therapy

    NASA Astrophysics Data System (ADS)

    Sirotkina, Marina A.; Kiseleva, Elena B.; Gubarkova, Ekaterina V.; Matveev, Lev A.; Zaitsev, Vladimir Yu.; Matveyev, Alexander L.; Shirmanova, Marina V.; Sovetsky, Alexander A.; Moiseev, Alexander A.; Zagaynova, Elena V.; Vitkin, Alex; Gladkova, Natalia D.

    2017-07-01

    Multimodal OCT is a promising tool for monitoring of individual tumor response to antitumor therapies. The changes of tumor cells, connective tissue, microcirculation and stiffness can be estimated simultaneously in real time with high resolution.

  4. Portable Runway Intersection Display and Monitoring System

    NASA Technical Reports Server (NTRS)

    Elrod, Susan Vinz (Inventor); Dabney, Richard W. (Inventor)

    2011-01-01

    Systems, methods and apparatus are provided through which an apparatus located on an airfield provides information to pilots in aircraft on the ground and simultaneously gathers information on the motion and position of the aircraft for controllers.

  5. Social status determines how we monitor and evaluate our performance

    PubMed Central

    Kostermans, Evelien; Milivojevic, Branka; De Cremer, David

    2012-01-01

    Since people with low status are more likely to experience social evaluative threat and are therefore more inclined to monitor for these threats and inhibit approach behaviour, we expected that low-status subjects would be more engaged in evaluating their own performance, compared with high-status subjects. We created a highly salient social hierarchy based on the performance of a simple time estimation task. Subjects could achieve high, middle or low status while performing this task simultaneously with other two players who were either higher or lower in status. Subjects received feedback on their own performance, as well as on the performance of the other two players simultaneously. Electroencephalography (EEG) was recorded from all three participants. The results showed that medial frontal negativity (an event-related potential reflecting performance evaluation) was significantly enhanced for low-status subjects. Implications for status-related differences in goal-directed behaviour are discussed. PMID:21421733

  6. Real time, ambient air laser monitor for rare CO2 isotopic tracers: Δ13 C18 O16 O and Δ17 O

    NASA Astrophysics Data System (ADS)

    Nelson, David; Shorter, Joanne; McManus, Barry; Jervis, Dylan; Zahniser, Mark; Ono, Shuhei

    2017-04-01

    Greenhouse gas (GHG) emissions are the primary drivers of global climate change and hence there is a crucial need to quantify their sources and sinks. A powerful technique to help constrain source and sink strengths in GHG exchange processes is the analysis of the relative proportions of isotopic variants of GHGs. We present a new laser isotope monitor based on Tunable Infrared Laser Direct Absorption Spectroscopy (TILDAS) to measure the primary clumped isotopologue of CO2 (Δ13 C18 O16 O) and to simultaneously measure the mass independent 17 O-CO2 content (Δ17 O). The instrument directly measures dried atmospheric samples without cryogenic preconcentration of CO2 . The instrument has several novel features. The instrument's sensitivity is enhanced by employing a 400 meter optical absorption cell. Measurement drift is suppressed by using a rapid sample switching method with frequent comparison to a working reference. A new dual-pressure measurement scheme is demonstrated. This scheme solves the dynamic range challenge that arises in simultaneously measuring the main isotopologues of CO2 together with much less abundant clumped isotopologue species. Our initial results address measurement precision, measurement drift and calibration. We show the potential to reach 0.03 per mil repeatability with time resolution of 3 minutes and with minimal drift over an 18 hour measurement period. The instrument is sufficiently compact to be field deployed thus providing the possibility of continuous measurements of Δ13 C18 O16 O and Δ17 O rather than occasional flask samples.

  7. Development and validation of a sensitive LC/MS/MS method for the simultaneous determination of naloxone and its metabolites in mouse plasma.

    PubMed

    Jiang, Hongliang; Wang, Yurong; Shet, Manjunath S; Zhang, Yang; Zenke, Duane; Fast, Douglas M

    2011-09-01

    A rapid, specific, and reliable LC-MS/MS based bioanalytical method was developed and validated for the simultaneous determination of naloxone (NLX) and its two metabolites, 6β-naloxol (NLL) and naloxone-3β-D-glucuronide (NLG) in mouse plasma. The optimal chromatographic behavior of these analytes was achieved on an Aquasil C18 column (50 mm × 2.1 mm, 5 μm) using reversed phase chromatography. The total LC analysis time per injection was 2.5 min with a flow rate of 1.0 mL/min with gradient elution. Sample preparation via protein precipitation with acetonitrile in a 96-well format was applied for analyses of these analytes. The analytes were monitored by electrospray ionization in positive ion multiple reaction monitoring (MRM) mode. Modification of collision energy besides chromatographic separation was applied to further eliminate interference peaks for NLL and NLG. The method validation was conducted over the curve range of 0.200/0.400/0.500 to 100/200/250 ng/mL for NLX/NLL/NLG, respectively, using 0.0250 mL of plasma sample. The intra- and inter-day precision and accuracy of the quality control samples at low, medium, and high concentration levels showed ≤ 6.5% relative standard deviation (RSD) and -8.3 to -2.5% relative error (RE). The method was successfully applied to determine the concentrations of NLX, NLL, and NLG in incurred mouse plasma samples. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. Assessment of Regional Ventilation Distribution: Comparison of Vibration Response Imaging (VRI) with Electrical Impedance Tomography (EIT)

    PubMed Central

    Bentley, Alexander H.; Hartmann, Erik K.; Klein, Klaus U.; Bodenstein, Marc; Baumgardner, James E.; David, Matthias; Ullrich, Roman; Markstaller, Klaus

    2014-01-01

    Background Vibration response imaging (VRI) is a bedside technology to monitor ventilation by detecting lung sound vibrations. It is currently unknown whether VRI is able to accurately monitor the local distribution of ventilation within the lungs. We therefore compared VRI to electrical impedance tomography (EIT), an established technique used for the assessment of regional ventilation. Methodology/Principal Findings Simultaneous EIT and VRI measurements were performed in the healthy and injured lungs (ALI; induced by saline lavage) at different PEEP levels (0, 5, 10, 15 mbar) in nine piglets. Vibration energy amplitude (VEA) by VRI, and amplitudes of relative impedance changes (rel.ΔZ) by EIT, were evaluated in seven regions of interest (ROIs). To assess the distribution of tidal volume (VT) by VRI and EIT, absolute values were normalized to the VT obtained by simultaneous spirometry measurements. Redistribution of ventilation by ALI and PEEP was detected by VRI and EIT. The linear correlation between pooled VT by VEA and rel.ΔZ was R2 = 0.96. Bland-Altman analysis showed a bias of −1.07±24.71 ml and limits of agreement of −49.05 to +47.36 ml. Within the different ROIs, correlations of VT-distribution by EIT and VRI ranged between R2 values of 0.29 and 0.96. ALI and PEEP did not alter the agreement of VT between VRI and EIT. Conclusions/Significance Measurements of regional ventilation distribution by VRI are comparable to those obtained by EIT. PMID:24475160

  9. Structural insights into the thermal decomposition sequence of barium tetrahydrogenorthotellurate(VI), Ba[H{sub 4}TeO{sub 6}

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weil, Matthias, E-mail: Matthias.Weil@tuwien.ac.at; Stöger, Berthold; Gierl-Mayer, Christian

    2016-09-15

    The compounds Ba[H{sub 4}TeO{sub 6}] (I), Ba[H{sub 2}TeO{sub 5}] (II), Ba[Te{sub 2}O{sub 6}(OH){sub 2}] (III) and Ba[TeO{sub 4}] (IV) were prepared by application of a diffusion method (I), under hydrothermal conditions (II and III) and from solid state reactions (IV), respectively. Structure analysis on the basis of single crystal X-ray diffraction data revealed novel structure types for (I), (II) and (III) and isotypism of (IV) with PrSbO{sub 4} and LaSbO{sub 4}. Common feature of the four oxotellurate(VI) structures are [TeO{sub 6}] octahedra. Whereas in the crystal structure of (I) the octahedral units are isolated, they are condensed into chains viamore » corner-sharing in (II) and via edge-sharing in (III) and (IV). The coordination numbers of the barium cations in the four structures range from seven to ten. Although hydrogen atom positions could not be located for the structures of (I) and (II), short interpolyhedral O···O contacts are evident for strong hydrogen bonding. The temperature behaviour of (I), (II) and (IV) was monitored by simultaneous thermal analysis (STA) measurements and in situ powder X-ray diffraction, revealing the decomposition sequence Ba[H{sub 4}TeO{sub 6}] → Ba[H{sub 2}TeO{sub 5}] → Ba[TeO{sub 4}]→ Ba[TeO{sub 3}] upon heating to temperatures up to 900 °C. - Graphical abstract: The crystal structures of the four oxotellurates(VI) were determined from single crystal data. The thermal decomposition of Ba[H{sub 4}TeO{sub 6}], monitored by temperature-dependent X-ray powder diffraction and simultaneous thermal analysis measurements, involves two condensation reactions according to Ba[H{sub 4}TeO{sub 6}]→Ba[H{sub 2}TeO{sub 5}]+H{sub 2}O(↑)→Ba[TeO{sub 4}]+ H{sub 2}O(↑). Display Omitted.« less

  10. A smog chamber study coupling a photoionization aerosol electron/ion spectrometer to VUV synchrotron radiation: organic and inorganic-organic mixed aerosol analysis

    NASA Astrophysics Data System (ADS)

    Baeza-Romero, María Teresa; Gaie-Levrel, Francois; Mahjoub, Ahmed; López-Arza, Vicente; Garcia, Gustavo A.; Nahon, Laurent

    2016-07-01

    A reaction chamber was coupled to a photoionization aerosol time-of-flight mass spectrometer based on an electron/ion coincidence scheme and applied for on-line analysis of organic and inorganic-organic mixed aerosols using synchrotron tunable vacuum ultraviolet (VUV) photons as the ionization source. In this proof of principle study, both aerosol and gas phase were detected simultaneously but could be differentiated. Present results and perspectives for improvement for this set-up are shown in the study of ozonolysis ([O3] = 0.13-3 ppm) of α-pinene (2-3 ppm), and the uptake of glyoxal upon ammonium sulphate. In this work the ozone concentration was monitored in real time, together with the particle size distributions and chemical composition, the latter taking advantage of the coincidence spectrometer and the tuneability of the synchrotron radiation as a soft VUV ionization source.

  11. Towards Discovery and Targeted Peptide Biomarker Detection Using nanoESI-TIMS-TOF MS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garabedian, Alyssa; Benigni, Paolo; Ramirez, Cesar E.

    Abstract. In the present work, the potential of trapped ion mobility spectrometry coupled to TOF mass spectrometry (TIMS-TOF MS) for discovery and targeted monitoring of peptide biomarkers from human-in-mouse xenograft tumor tissue was evaluated. In particular, a TIMS-MS workflow was developed for the detection and quantification of peptide biomarkers using internal heavy analogs, taking advantage of the high mobility resolution (R = 150–250) prior to mass analysis. Five peptide biomarkers were separated, identified, and quantified using offline nanoESI-TIMSCID- TOF MS; the results were in good agreement with measurements using a traditional LC-ESI-MS/MS proteomics workflow. The TIMS-TOF MS analysis permitted peptidemore » biomarker detection based on accurate mobility, mass measurements, and high sequence coverage for concentrations in the 10–200 nM range, while simultaneously achieving discovery measurements« less

  12. Study of the ink-paper interaction by image analysis: surface and bulk inspection

    NASA Astrophysics Data System (ADS)

    Fiadeiro, Paulo T.; de O. Mendes, António; M. Ramos, Ana M.; L. de Sousa, Sónia C.

    2013-11-01

    In this work, two optical systems previously designed and implemented by our research team, were used to enable the surface and bulk inspection of the ink-paper interaction by image analysis. Basically, the first system works by ejecting micro-liter ink drops onto the papers surface while monitoring the event under three different views over time. The second system is used for sectioning the paper samples through their thickness and to simultaneously acquire images of the ink penetration of each section cut. In the performed experiments, three black inks of different brands and a common copy paper were chosen, used, and tested with the two developed optical systems. Both qualitative and quantitative analyses were carried out at the surface level and in the bulk of the paper. In terms of conclusions, it was shown that the three tested ink-paper combinations revealed very distinct characteristics.

  13. Adaptive distributed source coding.

    PubMed

    Varodayan, David; Lin, Yao-Chung; Girod, Bernd

    2012-05-01

    We consider distributed source coding in the presence of hidden variables that parameterize the statistical dependence among sources. We derive the Slepian-Wolf bound and devise coding algorithms for a block-candidate model of this problem. The encoder sends, in addition to syndrome bits, a portion of the source to the decoder uncoded as doping bits. The decoder uses the sum-product algorithm to simultaneously recover the source symbols and the hidden statistical dependence variables. We also develop novel techniques based on density evolution (DE) to analyze the coding algorithms. We experimentally confirm that our DE analysis closely approximates practical performance. This result allows us to efficiently optimize parameters of the algorithms. In particular, we show that the system performs close to the Slepian-Wolf bound when an appropriate doping rate is selected. We then apply our coding and analysis techniques to a reduced-reference video quality monitoring system and show a bit rate saving of about 75% compared with fixed-length coding.

  14. Hair as an alternative matrix in bioanalysis.

    PubMed

    Barbosa, Joana; Faria, Juliana; Carvalho, Félix; Pedro, Madalena; Queirós, Odília; Moreira, Roxana; Dinis-Oliveira, Ricardo Jorge

    2013-04-01

    Alternative matrices are steadily gaining recognition as biological samples for toxicological analyses. Hair presents many advantages over traditional matrices, such as urine and blood, since it provides retrospective information regarding drug exposure, can distinguish between chronic and acute or recent drug use by segmental analysis, is easy to obtain, and has considerable stability for long periods of time. For this reason, it has been employed in a wide variety of contexts, namely to evaluate workplace drug exposure, drug-facilitated sexual assault, pre-natal drug exposure, anti-doping control, pharmacological monitoring and alcohol abuse. In this article, issues concerning hair structure, collection, storage and analysis are reviewed. The mechanisms of drug incorporation into hair are briefly discussed. Analytical techniques for simultaneous drug quantification in hair are addressed. Finally, representative examples of drug quantification using hair are summarized, emphasizing its potentialities and limitations as an alternative biological matrix for toxicological analyses.

  15. [Weighted gene co-expression network analysis in biomedicine research].

    PubMed

    Liu, Wei; Li, Li; Ye, Hua; Tu, Wei

    2017-11-25

    High-throughput biological technologies are now widely applied in biology and medicine, allowing scientists to monitor thousands of parameters simultaneously in a specific sample. However, it is still an enormous challenge to mine useful information from high-throughput data. The emergence of network biology provides deeper insights into complex bio-system and reveals the modularity in tissue/cellular networks. Correlation networks are increasingly used in bioinformatics applications. Weighted gene co-expression network analysis (WGCNA) tool can detect clusters of highly correlated genes. Therefore, we systematically reviewed the application of WGCNA in the study of disease diagnosis, pathogenesis and other related fields. First, we introduced principle, workflow, advantages and disadvantages of WGCNA. Second, we presented the application of WGCNA in disease, physiology, drug, evolution and genome annotation. Then, we indicated the application of WGCNA in newly developed high-throughput methods. We hope this review will help to promote the application of WGCNA in biomedicine research.

  16. Theoretical analysis and modeling of Thickness-Expansion Mode (TEM) sensors for fluid characterization.

    PubMed

    Elvira, Luis; Resa, Pablo; Castro, Pedro

    2013-03-01

    In this paper, the principles of Thickness-Expansion Mode (TEM) resonators for the characterization of fluids are described. From the measurement of the resonance parameters of a TEM piezoelectric transducer, the compressional acoustic impedance of gases and liquids can be determined. Since the propagation of mechanical waves into the fluid is not necessary, information in a wide range of frequencies can be obtained. Alternatively, these sensors can be driven in combination with other ultrasonic techniques to simultaneously determine the density, speed of sound and viscosity of samples. Some potential applications include the probe monitoring of processes and the characterization of fluids under harsh conditions. The main experimental criteria for the design and construction of high-resolution impedance meters (such as piezoelectric material, protective coating or thermal response) have been studied using equivalent electrical circuit modeling and finite element analysis. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Simple and sensitive analysis of long-chain free fatty acids in milk by fluorogenic derivatization and high-performance liquid chromatography.

    PubMed

    Lu, Chi-Yu; Wu, Hsin-Lung; Chen, Su-Hwei; Kou, Hwang-Shang; Wu, Shou-Mei

    2002-01-02

    A highly sensitive high-performance liquid chromatography (HPLC) method is described for the simultaneous determination of some important saturated and unsaturated fatty acids in milk, including lauric (dodecanoic), myristic (tetradecanoic), palmitic (hexadecanoic), stearic (octadecanoic), palmitoleic (hexadecenoic), oleic (octadecenoic), and linoleic acids (octadecadienoic acids). The fatty acids were fluorogenically derivatized with 2-(2-naphthoxy)ethyl 2-(piperidino)ethanesulfonate (NOEPES) as their naphthoxyethyl derivatives. The resulting derivatives were separated by isocratic HPLC and monitored with a fluorometric detector (lambdaex = 235 nm, lambdaem = 350 nm). The fatty acids in milk were extracted with toluene, and the extract with the fatty acids was directly derivatized with NOEPES without solvent replacement. Determination of long-chain free fatty acids in milk is feasible by a standard addition method. A small amount of milk product, 10 microL, is sufficient for the analysis.

  18. Four-color single-molecule fluorescence with noncovalent dye labeling to monitor dynamic multimolecular complexes.

    PubMed

    DeRocco, Vanessa; Anderson, Trevor; Piehler, Jacob; Erie, Dorothy A; Weninger, Keith

    2010-11-01

    To enable studies of conformational changes within multimolecular complexes, we present a simultaneous, four-color single molecule fluorescence methodology implemented with total internal reflection illumination and camera-based, wide-field detection. We further demonstrate labeling histidine-tagged proteins noncovalently with Tris-nitrilotriacetic acid (Tris-NTA)-conjugated dyes to achieve single molecule detection. We combine these methods to colocalize the mismatch repair protein MutSα on DNA while monitoring MutSα-induced DNA bending using Förster resonance energy transfer (FRET) and to monitor assembly of membrane-tethered SNARE protein complexes.

  19. Four-color single molecule fluorescence with noncovalent dye labeling to monitor dynamic multimolecular complexes

    PubMed Central

    DeRocco, Vanessa C.; Anderson, Trevor; Piehler, Jacob; Erie, Dorothy A.; Weninger, Keith

    2010-01-01

    To allow studies of conformational changes within multi-molecular complexes, we present a simultaneous, 4-color single molecule fluorescence methodology implemented with total internal reflection illumination and camera based, wide-field detection. We further demonstrate labeling histidine-tagged proteins non-covalently with tris-Nitrilotriacetic acid (tris-NTA) conjugated dyes to achieve single molecule detection. We combine these methods to co-localize the mismatch repair protein MutSα on DNA while monitoring MutSα-induced DNA bending using Förster resonance energy transfer (FRET) and to monitor assembly of membrane-tethered SNARE protein complexes. PMID:21091445

  20. Fiber-Optic Based Compact Gas Leak Detection System

    NASA Technical Reports Server (NTRS)

    deGroot, Wim A.

    1995-01-01

    A propellant leak detection system based on Raman scattering principles is introduced. The proposed system is flexible and versatile as the result of the use of optical fibers. It is shown that multiple species can be monitored simultaneously. In this paper oxygen, nitrogen, carbon monoxide, and hydrogen are detected and monitored. The current detection sensitivity for both hydrogen and carbon monoxide is 1% partial pressure at ambient conditions. The sensitivity for oxygen and nitrogen is 0.5% partial pressure. The response time to changes in species concentration is three minutes. This system can be used to monitor multiple species at several locations.

Top