Sample records for monitoring study aims

  1. Calibration of Comprehension and Performance in L2 Reading

    ERIC Educational Resources Information Center

    Sarac, Seda; Tarhan, Betul

    2009-01-01

    Comprehension monitoring is crucial for successful reading. Although the researchers appreciate the importance of comprehension monitoring in L2 reading, there are only a few studies done on the comprehension monitoring ability of L2 readers. The main aim of this study was to investigate the comprehension monitoring abilities of university…

  2. Real-Time Human Ambulation, Activity, and Physiological Monitoring: Taxonomy of Issues, Techniques, Applications, Challenges and Limitations

    PubMed Central

    Khusainov, Rinat; Azzi, Djamel; Achumba, Ifeyinwa E.; Bersch, Sebastian D.

    2013-01-01

    Automated methods of real-time, unobtrusive, human ambulation, activity, and wellness monitoring and data analysis using various algorithmic techniques have been subjects of intense research. The general aim is to devise effective means of addressing the demands of assisted living, rehabilitation, and clinical observation and assessment through sensor-based monitoring. The research studies have resulted in a large amount of literature. This paper presents a holistic articulation of the research studies and offers comprehensive insights along four main axes: distribution of existing studies; monitoring device framework and sensor types; data collection, processing and analysis; and applications, limitations and challenges. The aim is to present a systematic and most complete study of literature in the area in order to identify research gaps and prioritize future research directions. PMID:24072027

  3. The Aims and Objectives of the Monitoring the Future Study and Progress toward Fulfilling Them as of 2001. Monitoring the Future Occasional Paper 52.

    ERIC Educational Resources Information Center

    Johnston, Lloyd D.; O'Malley, Patrick M.; Schulenberg, John E.; Bachman, Jerald G.

    Monitoring the Future is an ongoing program of research intended to assess the changing lifestyles, values, and preferences of American youth. This publication, from the occasional paper series, describes a study that monitors drug use and potential explanatory factors among American secondary school students, college students, and young adults.…

  4. Primary School Principals' Self-Monitoring Skills

    ERIC Educational Resources Information Center

    Konan, Necdet

    2015-01-01

    The aim of the present study is to identify primary school principals' self-monitoring skills. The study adopted the general survey model and its population comprised primary school principals serving in the city of Diyarbakir, Turkey, while 292 of these constituted the sample. Self-Monitoring Scale was used as the data collection instrument. In…

  5. Literature review on monitoring technologies and their outcomes in independently living elderly people.

    PubMed

    Peetoom, Kirsten K B; Lexis, Monique A S; Joore, Manuela; Dirksen, Carmen D; De Witte, Luc P

    2015-07-01

    To obtain insight into what kind of monitoring technologies exist to monitor activity in-home, what the characteristics and aims of applying these technologies are, what kind of research has been conducted on their effects and what kind of outcomes are reported. A systematic document search was conducted within the scientific databases Pubmed, Embase, Cochrane, PsycINFO and Cinahl, complemented by Google Scholar. Documents were included in this review if they reported on monitoring technologies that detect activities of daily living (ADL) or significant events, e.g. falls, of elderly people in-home, with the aim of prolonging independent living. Five main types of monitoring technologies were identified: PIR motion sensors, body-worn sensors, pressure sensors, video monitoring and sound recognition. In addition, multicomponent technologies and smart home technologies were identified. Research into the use of monitoring technologies is widespread, but in its infancy, consisting mainly of small-scale studies and including few longitudinal studies. Monitoring technology is a promising field, with applications to the long-term care of elderly persons. However, monitoring technologies have to be brought to the next level, with longitudinal studies that evaluate their (cost-) effectiveness to demonstrate the potential to prolong independent living of elderly persons. [Box: see text].

  6. Optimizing bulk milk dioxin monitoring based on costs and effectiveness.

    PubMed

    Lascano-Alcoser, V H; Velthuis, A G J; van der Fels-Klerx, H J; Hoogenboom, L A P; Oude Lansink, A G J M

    2013-07-01

    Dioxins are environmental pollutants, potentially present in milk products, which have negative consequences for human health and for the firms and farms involved in the dairy chain. Dioxin monitoring in feed and food has been implemented to detect their presence and estimate their levels in food chains. However, the costs and effectiveness of such programs have not been evaluated. In this study, the costs and effectiveness of bulk milk dioxin monitoring in milk trucks were estimated to optimize the sampling and pooling monitoring strategies aimed at detecting at least 1 contaminated dairy farm out of 20,000 at a target dioxin concentration level. Incidents of different proportions, in terms of the number of contaminated farms, and concentrations were simulated. A combined testing strategy, consisting of screening and confirmatory methods, was assumed as well as testing of pooled samples. Two optimization models were built using linear programming. The first model aimed to minimize monitoring costs subject to a minimum required effectiveness of finding an incident, whereas the second model aimed to maximize the effectiveness for a given monitoring budget. Our results show that a high level of effectiveness is possible, but at high costs. Given specific assumptions, monitoring with 95% effectiveness to detect an incident of 1 contaminated farm at a dioxin concentration of 2 pg of toxic equivalents/g of fat [European Commission's (EC) action level] costs €2.6 million per month. At the same level of effectiveness, a 73% cost reduction is possible when aiming to detect an incident where 2 farms are contaminated at a dioxin concentration of 3 pg of toxic equivalents/g of fat (EC maximum level). With a fixed budget of €40,000 per month, the probability of detecting an incident with a single contaminated farm at a dioxin concentration equal to the EC action level is 4.4%. This probability almost doubled (8.0%) when aiming to detect the same incident but with a dioxin concentration equal to the EC maximum level. This study shows that the effectiveness of finding an incident depends not only on the ratio at which, for testing, collected truck samples are mixed into a pooled sample (aiming at detecting certain concentration), but also the number of collected truck samples. In conclusion, the optimal cost-effective monitoring depends on the number of contaminated farms and the concentration aimed at detection. The models and study results offer quantitative support to risk managers of food industries and food safety authorities. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  7. Comprehensive evaluation of compaction of asphalt pavements and development of compaction monitoring system.

    DOT National Transportation Integrated Search

    2012-04-01

    This study aimed to conduct a comprehensive evaluation of compaction of asphalt pavements and : develop software for monitoring field compaction in real time. In the first phase of this study, the researchers : built several test sections that were c...

  8. Assessing exposures to household air pollution in public health research and program evaluation.

    PubMed

    Northcross, Amanda L; Hwang, Nina; Balakrishnan, Kalpana; Mehta, Sumi

    2015-03-01

    Exposure to smoke from the use of solid fuels and inefficient stoves for cooking and heating is responsible for approximately 4 million premature deaths yearly. As increasing investments are made to tackle this important public health issue, there is a need for identifying and providing guidance on best practices for exposure and stove performance monitoring, particularly for public health research and evaluation studies. This paper, which builds upon the discussion at an expert consultation on exposure assessment convened by the Global Alliance for Clean Cookstoves, the Centers for Disease Control and Prevention, and PATH in late 2012, aims to provide general guidance on what to monitor, who and where to monitor, and how to monitor household air pollution exposures. In addition, we summarize information about commercially available monitoring equipment and the technical properties of these monitors most important for household air pollution exposure assessment. The target audience includes epidemiologists conducting health studies and program evaluators aiming to quantify changes in exposures to estimate the potential health benefits of cookstoves intervention projects.

  9. Smart rocks and wireless communication system for real-time monitoring and mitigation of bridge scour : a proof-of-concept study.

    DOT National Transportation Integrated Search

    2013-12-01

    This study aims to integrate commercial measurement and communication components into a scour : monitoring system with magnets or electronics embedded in smart rocks, and evaluate and improve its : performance in laboratory and field conditions for t...

  10. Specialist Cohort Event Monitoring studies: a new study method for risk management in pharmacovigilance.

    PubMed

    Layton, Deborah; Shakir, Saad A W

    2015-02-01

    The evolving regulatory landscape has heightened the need for innovative, proactive, efficient and more meaningful solutions for 'real-world' post-authorization safety studies (PASS) that not only align with risk management objectives to gather additional safety monitoring information or assess a pattern of drug utilization, but also satisfy key regulatory requirements for marketing authorization holder risk management planning and execution needs. There is a need for data capture across the primary care and secondary care interface, or for exploring use of new medicines in secondary care to support conducting PASS. To fulfil this need, event monitoring has evolved. The Specialist Cohort Event Monitoring (SCEM) study is a new application that enables a cohort of patients prescribed a medicine in the hospital and secondary care settings to be monitored. The method also permits the inclusion of a comparator cohort of patients receiving standard care, or another counterfactual comparator group, to be monitored concurrently, depending on the study question. The approach has been developed in parallel with the new legislative requirement for pharmaceutical companies to undertake a risk management plan as part of post-authorization safety monitoring. SCEM studies recognize that the study population comprises those patients who may have treatment initiated under the care of specialist health care professionals and who are more complex in terms of underlying disease, co-morbidities and concomitant medications than the general disease population treated in primary care. The aims of this paper are to discuss the SCEM new-user study design, rationale and features that aim to address possible bias (such as selection bias) and current applications.

  11. Students Who Bully and Their Perceptions of Teacher Support and Monitoring

    ERIC Educational Resources Information Center

    Ertesvåg, Sigrun K.

    2016-01-01

    The aim of this study was to assess students who bully and their perception of the emotional support, monitoring and instructional support offered by their teachers. Although research on bullying has increased over the past few decades, research on students who bully and their perceptions of their teachers' support and monitoring is scarce.…

  12. Android Based Area Web Monitoring

    NASA Astrophysics Data System (ADS)

    Kanigoro, Bayu; Galih Salman, Afan; Moniaga, Jurike V.; Chandra, Eric; Rezky Chandra, Zein

    2014-03-01

    The research objective is to develop an application that can be used in the monitoring of an area by using a webcam. It aims to create a sense of security on the user's application because it can monitor an area using mobile phone anywhere. The results obtained in this study is to create an area with a webcam monitoring application that can be accessed anywhere as long as the monitoring results have internet access and can also be accessed through Android Based Mobile Phone.

  13. Feasibility of portable sleep monitors to detect obstructive sleep apnea (OSA) in a vulnerable urban population.

    PubMed

    Nickerson, Jillian; Lee, Euny; Nedelman, Michael; Aurora, R Nisha; Krieger, Ana; Horowitz, Carol R

    2015-01-01

    Portable sleep monitors may offer a convenient method to expand detection of obstructive sleep apnea (OSA), yet few studies have evaluated this technology in vulnerable populations. We therefore aimed to assess the feasibility and acceptability of portable sleep monitors for detection of OSA in a prediabetic, urban minority population. We recruited a convenience sample of participants at their 12-month follow-up for a community-partnered, peer-led lifestyle intervention aimed to prevent diabetes in prediabetic and overweight patients in this prospective mixed-methods pilot study. All participants wore portable sleep monitors overnight at home. We qualitatively explored perceptions about OSA and portable monitors in a subset of participants. We tested 72 people, predominantly non-White, female, Spanish speaking, uninsured, and of low income. Use of portable sleep monitors was feasible: 100% of the monitors were returned and all participants received results. We detected OSA in 49% (defined as an Apnea-Hypopnea Index [AHI] >5) and moderate-severe OSA in 14% (AHI >15) requiring treatment in 14%. In 21 qualitative interviews, participants supported increased use of portable sleep monitors in their community, were appropriately concerned that OSA could cause progression to diabetes, and thought weight loss could prevent or improve OSA. Portable sleep monitors may represent a feasible method for detecting OSA in high-risk urban minority populations. © Copyright 2015 by the American Board of Family Medicine.

  14. Notebook computer use with different monitor tilt angle: effects on posture, muscle activity and discomfort of neck pain users.

    PubMed

    Chiou, Wen-Ko; Chou, Wei-Ying; Chen, Bi-Hui

    2012-01-01

    This study aimed to evaluate the posture, muscle activities, and self reported discomforts of neck pain notebook computer users on three monitor tilt conditions: 100°, 115°, and 130°. Six subjects were recruited in this study to completed typing tasks. Results showed subjects have a trend to show the forward head posture in the condition that monitor was set at 100°, and the significant less neck and shoulder discomfort were noted in the condition that monitor was set at 130°. These result suggested neck pain notebook user to set their monitor tilt angle at 130°.

  15. Forest health monitoring and forestry implications in the Czech Republic

    Treesearch

    Martin Cerny; Pavel Moravcik

    1998-01-01

    In recent years, a forest monitoring program in the Czech Republic was extended into more detailed monitoring that aimed to describe the extent of changes in forest vitality and identify the nature and the main causes of these changes on local and regional scales. Studies were undertaken in six mountain areas in the Czech Republic. The program of regional forest...

  16. Developmental Changes in Error Monitoring: An Event-Related Potential Study

    ERIC Educational Resources Information Center

    Wiersema, Jan R.; van der Meere, Jacob J.; Roeyers, Herbert

    2007-01-01

    The aim of the study was to investigate the developmental trajectory of error monitoring. For this purpose, children (age 7-8), young adolescents (age 13-14) and adults (age 23-24) performed a Go/No-Go task and were compared on overt reaction time (RT) performance and on event-related potentials (ERPs), thought to reflect error detection…

  17. Progress Monitoring the Effects of Daily Report Cards across Elementary and Secondary Settings Using Direct Behavior Rating: Single Item Scales

    ERIC Educational Resources Information Center

    Miller, Faith G.; Crovello, Nicholas J.; Chafouleas, Sandra M.

    2017-01-01

    Direct Behavior Rating-Single Item Scales (DBR-SIS) have been advanced as a promising, systematic, behavioral, progress-monitoring method that is flexible, efficient, and defensible. This study aimed to extend existing literature on the use of DBR-SIS in elementary and secondary settings, and to examine methods of monitoring student progress in…

  18. [Application of CWT to extract characteristic monitoring parameters during spine surgery].

    PubMed

    Chen, Penghui; Wu, Baoming; Hu, Yong

    2005-10-01

    It is necessary to monitor intraoperative spinal function in order to prevent spinal neurological deficit during spine surgery. This study aims to extract characteristic electrophysiological monitoring parameters during surgical treatment of scoliosis. The problem, "the monitoring parameters in time domain are of great variability and are sensitive to noise", may also be solved in this study. By use of continuous wavelet transform to analyze the intraoperative cortical somatosensory evoked potential (CSEP), three new characteristic monitoring parameters in time-frequency domain (TFD) are extracted. The results indicate that the variability of CSEP characteristic parameters in TFD is lower than the variability of those in time domain. Therefore, the TFD characteristic monitoring parameters are more stable and reliable parameters of latency and amplitude in time domain. The application of TFD monitoring parameters during spine surgery may avoid spinal injury effectively.

  19. Cost-effectiveness of monitoring free flaps.

    PubMed

    Subramaniam, Shiva; Sharp, David; Jardim, Christopher; Batstone, Martin D

    2016-06-01

    Methods of free flap monitoring have become more sophisticated and expensive. This study aims to determine the cost of free flap monitoring and examine its cost effectiveness. We examined a group of patients who had had free flaps to the head and neck over a two-year period, and combined these results with costs obtained from business managers and staff. There were 132 free flaps with a success rate of 99%. The cost of monitoring was Aus $193/flap. Clinical monitoring during this time period cost Aus$25 476 and did not lead to the salvage of any free flaps. Cost equivalence is reached between monitoring and not monitoring only at a failure rate of 15.8%. This is to our knowledge the first study to calculate the cost of clinical monitoring of free flaps, and to examine its cost-effectiveness. Copyright © 2016 The British Association of Oral and Maxillofacial Surgeons. All rights reserved.

  20. Smart rock technology for real-time monitoring of bridge scour and riprap effectiveness - design guidelines and visualization tool.

    DOT National Transportation Integrated Search

    2016-12-31

    This study aims to further develop and demonstrate the recently-proposed smart rock technology for : scour depth and protection effectiveness monitoring. A smart rock is one or two stacked magnets encased : in a concrete sphere with a specially-desig...

  1. Developmental monitoring using caregiver reports in a resource-limited setting: the case of Kilifi, Kenya

    PubMed Central

    Abubakar, A; Holding, P; Van de Vijver, F; Bomu, G; Van Baar, A

    2010-01-01

    Aim: The main aim of the current study was to evaluate the reliability, validity and acceptability of developmental monitoring using caregiver reports among mothers in a rural African setting. Methods: A structured interview for parents of children aged 24 months and less was developed through both participant consultation and a review of literature. The reliability and validity of the schedule was evaluated through a 10-month monitoring programme of 95 children, aged 2–10 months. The acceptability of the process was evaluated by studying retention rates and by organizing focus group discussions with participating mothers. Results: The structured interview ‘Developmental Milestones Checklist’ consisted of 66 items covering three broad domains of child functioning: motor, language and personal–social development. The interview yielded scores of developmental achievements that showed high internal consistency and excellent test–retest reliability. The results were sensitive to maturational changes and nutritional deficiencies. In addition, acceptable retention rates of approximately 80% were found. Participating mothers reported that they found the procedures both acceptable and beneficial. Conclusion: Developmental monitoring using caregiver report is a viable method to identify and monitor at-risk children in Sub-Saharan Africa. PMID:20353499

  2. Ethical considerations in adherence research.

    PubMed

    Patel, Nupur U; Moore, Blake A; Craver, Rebekah F; Feldman, Steven R

    2016-01-01

    Poor adherence to treatment is a common cause of medical treatment failure. Studying adherence is complicated by the potential for the study environment to impact adherence behavior. Studies performed without informing patients about adherence monitoring must balance the risks of deception against the potential benefits of the knowledge to be gained. Ethically monitoring a patient's adherence to a treatment plan without full disclosure of the monitoring plan requires protecting the patient's rights and upholding the fiduciary obligations of the investigator. Adherence monitoring can utilize different levels of deception varying from stealth monitoring, debriefing after the study while informing the subject that some information had been withheld in regard to the use of adherence monitoring (withholding), informed consent that discloses some form of adherence monitoring is being used and will be disclosed at the end of the study (authorized deception), and full disclosure. Different approaches offer different benefits and potential pitfalls. The approach used must balance the risk of nondisclosure against the potential for confounding the adherence monitoring data and the potential benefits that adherence monitoring data will have for the research subjects and/or other populations. This commentary aims to define various methods of adherence monitoring and to provide a discussion of the ethical considerations that accompany the use of each method and adherence monitoring in general as it is used in clinical research.

  3. Automated Iodine Monitoring System Development (AIMS). [shuttle prototype

    NASA Technical Reports Server (NTRS)

    1975-01-01

    The operating principle of the automated iodine monitoring/controller system (AIMS) is described along with several design modifications. The iodine addition system is also discussed along with test setups and calibration; a facsimile of the optical/mechanical portion of the iodine monitor was fabricated and tested. The appendices include information on shuttle prototype AIMS, preliminary prime item development specifications, preliminary failure modes and effects analysis, and preliminary operating and maintenance instructions.

  4. Comparison and cost analysis of drinking water quality monitoring requirements versus practice in seven developing countries.

    PubMed

    Crocker, Jonny; Bartram, Jamie

    2014-07-18

    Drinking water quality monitoring programs aim to support provision of safe drinking water by informing water quality management. Little evidence or guidance exists on best monitoring practices for low resource settings. Lack of financial, human, and technological resources reduce a country's ability to monitor water supply. Monitoring activities were characterized in Cambodia, Colombia, India (three states), Jordan, Peru, South Africa, and Uganda according to water sector responsibilities, monitoring approaches, and marginal cost. The seven study countries were selected to represent a range of low resource settings. The focus was on monitoring of microbiological parameters, such as E. coli, coliforms, and H2S-producing microorganisms. Data collection involved qualitative and quantitative methods. Across seven study countries, few distinct approaches to monitoring were observed, and in all but one country all monitoring relied on fixed laboratories for sample analysis. Compliance with monitoring requirements was highest for operational monitoring of large water supplies in urban areas. Sample transport and labor for sample collection and analysis together constitute approximately 75% of marginal costs, which exclude capital costs. There is potential for substantive optimization of monitoring programs by considering field-based testing and by fundamentally reconsidering monitoring approaches for non-piped supplies. This is the first study to look quantitatively at water quality monitoring practices in multiple developing countries.

  5. Using Data to Individualize a Multicomponent, Technology-Based Self-Monitoring Intervention

    ERIC Educational Resources Information Center

    Bruhn, Allison Leigh; Vogelgesang, Kari; Fernando, Josephine; Lugo, Wilbeth

    2016-01-01

    Technology in schools is abundant as is the call for evidence-based interventions for students who need additional support to be successful. One promising use of technology is for self-monitoring interventions aimed at improving classroom behavior. In this study, two middle school students with disabilities used a multicomponent, self-monitoring…

  6. AIM-Monitoring: a component of the BLM assessment, inventory, and monitoring strategy

    USDA-ARS?s Scientific Manuscript database

    The “BLM Assessment, Inventory, and Monitoring Strategy for Integrated Renewable Resources Management” (AIM Strategy) was completed in 2011 in response to a request from the Office of Management and Budget. The strategy describes an approach for integrated, cross-program assessment, inventory, and m...

  7. An Enlightened Use of Educational Monitoring for Greece

    ERIC Educational Resources Information Center

    Korilaki, Panayota

    2006-01-01

    Purpose: This paper aims to discuss the issues surrounding educational monitoring systems. Design/methodology/approach: This paper is a general review of the situation in Greece. Findings: This paper suggests that a superior educational monitoring system aiming to alleviate educational and social inequalities as well as discrepancies between…

  8. Examination on the use of acoustic emission for monitoring metal forging process: A study using simulation technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mullins, W.M.; Irwin, R.D.; Malas, J.C. III

    The aim of this study is to determine the feasibility of using acoustic emission as a monitoring technique for metal forging operations. From the sensor development paradigm proposed by McClean et al. the most likely approach to determining feasibility for application is through signal recognition. For this reason, signature prediction and analysis was chosen to determine the suitability for forging applications.

  9. Electronic monitoring of patient adherence to oral antihypertensive medical treatment: a systematic review.

    PubMed

    Christensen, Arne; Osterberg, Lars G; Hansen, Ebba Holme

    2009-08-01

    Poor patient adherence is often the reason for suboptimal blood pressure control. Electronic monitoring is one method of assessing adherence. The aim was to systematically review the literature on electronic monitoring of patient adherence to self-administered oral antihypertensive medications. We searched the Pubmed, Embase, Cinahl and Psychinfo databases and websites of suppliers of electronic monitoring devices. The quality of the studies was assessed according to the quality criteria proposed by Haynes et al. Sixty-two articles were included; three met the criteria proposed by Haynes et al. and nine reported the use of electronic adherence monitoring for feedback interventions. Adherence rates were generally high, whereas average study quality was low with a recent tendency towards improved quality. One study detected investigator fraud based on electronic monitoring data. Use of electronic monitoring of patient adherence according to the quality criteria proposed by Haynes et al. has been rather limited during the past two decades. Electronic monitoring has mainly been used as a measurement tool, but it seems to have the potential to significantly improve blood pressure control as well and should be used more widely.

  10. An observational study on patient admission in the anaesthesia gas monitor and minimum alveolar concentration monitoring: A deficiency with huge impact

    PubMed Central

    Karim, Habib Md Reazaul; Narayan, Anilkumar; Yunus, Md; Kumar, Sanjay; Prakash, Avinash; Sahoo, Sarasa Kumar

    2017-01-01

    Background and Aims: Minimum alveolar concentration (MAC) monitoring is an integral part of modern-day anaesthesia. Both MAC and MAC-awake are age dependant, and age of the patient needs to be entered in the monitor. This study was aimed to assess the practice of patient birth year entry in the anaesthesia monitor and its impact on MAC monitoring. Methods: Sixty volatile anaesthetic-based general anaesthetics (GAs) were observed silently in two tertiary care teaching hospitals with regard to ‘birth year’ entry in the patient monitor. The impact on MAC for non-entry of age was assessed. The observed MAC reading and the MAC corrected for age (MACage) of the patients were noted. Paired t-test was used to compare the differences in observed MAC and MACage values. P <0.05 was significant. Results: Sixty GAs of patients aged between 10 and 68 years were observed; 96.67% anaesthetics were conducted without entering ‘birth year’. Thirty-four patients (mean age 35.14 ± 15.38 years) were further assessed for impact of non-entry of age. The observed MAC was similar to MACage in patients aged 40 ± 5 years (36–45 years group). Nearly 79.41% of the observed MACs were incorrect; 55.88% patients were potentially underdosed whereas 23.53% were overdosed. Conclusion: Omitting patient age entry in the monitor results in erroneous MAC values, exposing patients <40 years to underdosing and older patients to overdose. PMID:28794529

  11. Molecular Imaging and Therapy of Prostate Cancer

    DTIC Science & Technology

    2015-10-01

    arsenic-based, IGF1R-targeted radiopharmaceuticals can allow for PET imaging, IRT, and monitoring the therapeutic response of PCa. Specific Aims: Aim 1: To...models with PET imaging. Aim 3: To monitor the efficacy of 76As-based IRT of PCa with multimodality imaging.

  12. The Contribution of School-Related Parental Monitoring, Self-Determination, and Self-Efficacy to Academic Achievement

    ERIC Educational Resources Information Center

    Affuso, Gaetana; Bacchini, Dario; Miranda, Maria Concetta

    2017-01-01

    The aim of this study was to examine the contribution of school-related parental monitoring (SR-PM), self-determined motivation, and academic self-efficacy to academic achievement across time. The authors hypothesized that SR-PM would affect academic achievement indirectly via its effects on self-determined motivation and academic self-efficacy…

  13. Monitoring Makes a Difference: Quality and Temporal Variation in Teacher Education Students' Collaborative Learning

    ERIC Educational Resources Information Center

    Näykki, Piia; Järvenoja, Hanna; Järvelä, Sanna; Kirschner, Paul

    2017-01-01

    The aim of this process-oriented video-observation study is to explore how groups that perform differently differ in terms of the number, quality, and temporal variation of their content-level (knowledge co-construction) and meta-level (monitoring) activities. Five groups of teacher education students (n = 22) were observed throughout a 3-month…

  14. Metacognitive Processes in Emotion Recognition: Are They Different in Adults with Asperger's Disorder?

    ERIC Educational Resources Information Center

    Sawyer, Alyssa C. P.; Williamson, Paul; Young, Robyn

    2014-01-01

    Deficits in emotion recognition and social interaction characterize individuals with Asperger's Disorder (AS). Moreover they also appear to be less able to accurately use confidence to gauge their emotion recognition accuracy (i.e., metacognitive monitoring). The aim of this study was to extend this finding by considering both monitoring and…

  15. The Southern and Eastern Africa Consortium for Monitoring Educational Quality. Assessment GEMs No. 8

    ERIC Educational Resources Information Center

    Australian Council for Educational Research, 2015

    2015-01-01

    The Southern and Eastern Africa Consortium for Monitoring Educational Quality (SACMEQ) carries out large-scale cross-national research studies in member countries in the Southern and Eastern Africa region. It aims to assess the conditions of schooling and performance levels of learners and teachers in the areas of literacy and numeracy. SACMEQ has…

  16. Comparison and Cost Analysis of Drinking Water Quality Monitoring Requirements versus Practice in Seven Developing Countries

    PubMed Central

    Crocker, Jonny; Bartram, Jamie

    2014-01-01

    Drinking water quality monitoring programs aim to support provision of safe drinking water by informing water quality management. Little evidence or guidance exists on best monitoring practices for low resource settings. Lack of financial, human, and technological resources reduce a country’s ability to monitor water supply. Monitoring activities were characterized in Cambodia, Colombia, India (three states), Jordan, Peru, South Africa, and Uganda according to water sector responsibilities, monitoring approaches, and marginal cost. The seven study countries were selected to represent a range of low resource settings. The focus was on monitoring of microbiological parameters, such as E. coli, coliforms, and H2S-producing microorganisms. Data collection involved qualitative and quantitative methods. Across seven study countries, few distinct approaches to monitoring were observed, and in all but one country all monitoring relied on fixed laboratories for sample analysis. Compliance with monitoring requirements was highest for operational monitoring of large water supplies in urban areas. Sample transport and labor for sample collection and analysis together constitute approximately 75% of marginal costs, which exclude capital costs. There is potential for substantive optimization of monitoring programs by considering field-based testing and by fundamentally reconsidering monitoring approaches for non-piped supplies. This is the first study to look quantitatively at water quality monitoring practices in multiple developing countries. PMID:25046632

  17. Parental Monitoring, Parent-Adolescent Communication, and Adolescents’ Trust in Their Parents in China

    PubMed Central

    Ying, Liuhua; Ma, Fengling; Huang, Huahua; Guo, Xiaolin; Chen, Chuansheng; Xu, Fen

    2015-01-01

    Purpose Trust is an important aspect of interpersonal relationships, but little is known about adolescents’ interpersonal trust. The aim of the present study was to examine the associations among parental monitoring, parent-adolescent communication, and adolescents’ trust in their parents in China. Methods Data in this study were collected as part of the cross-sectional study of children in China. 3349 adolescents (female 48.6%, age range of 12–15 years) were randomly selected from 35 secondary schools in April, 2009 and administered to the Adolescent Interpersonal Trust Scale, the Parental Monitoring Scale, and the Parent-Adolescent Communication Scale. Results Adolescents’ trust in their parents was positively related to parental monitoring and parent-adolescent communication. Furthermore, parent-adolescent communication mediated the association between parental monitoring and adolescents’ trust in their parents. The mediation model fit data of both genders and three age groups equally well. Conclusions Parental monitoring and parent-adolescent communication play an importance role in fostering adolescents’ trust in their parents. PMID:26271080

  18. The use of thermal imaging to monitoring skin temperature during cryotherapy: A systematic review

    NASA Astrophysics Data System (ADS)

    Matos, Filipe; Neves, Eduardo Borba; Norte, Marco; Rosa, Claudio; Reis, Victor Machado; Vilaça-Alves, José

    2015-11-01

    Cryotherapy has been applied on clinical injuries and as a method for exercise recovery. It is aimed to reduce edema, nervous conduction velocity, and tissue metabolism, as well as to accelerate the recovery process of the muscle injury induced by exercise. Objective: This review aim to investigate the applicability of thermal imaging as a method for monitoring skin temperature during cryotherapy. Method: Search the Web of Science database using the terms "Cryotherapy", "Thermography", "Thermal Image" and "Cooling". Results: Nineteen studies met the inclusion criteria and pass the PEDro scale quality evaluation. Evidence support the use of thermal imaging as a method for monitoring the skin temperature during cryotherapy, and it is superior to other contact methods and subjective methods of assessing skin temperature. Conclusion: Thermography seems to be an efficient, trustworthy and secure method in order to monitoring skin temperature during cryotherapy application. Evidence supports the use of thermography in detriment of contact methods as well as other subjective ones.

  19. [Source-monitoring deficits in schizophrenia: review and pharmacotherapeutic implications].

    PubMed

    Juhász, Levente Zsolt; Bartkó, György

    2007-03-01

    The disturbance of source-monitoring is one of the various impairments in cognitive functioning observed in schizophrenic patients. The process of source-monitoring allows individuals to distinguish self generated thoughts and behaviours from those generated by others. The aim of the present study is to review the general psychological definition of source memory and source-monitoring and its neurological basis as well as the models for explanation of source-monitoring deficits. The relationship between source-monitoring-deficits and psychopathological symptoms as well as the effect of antipsychotic treatment on source-monitoring disturbances are introduced. There is evidence suggesting, that a selective source-monitoring deficit is in the occurrence of auditory hallucinations. The disturbance of prospective memory may influence unfavorably the compliance. Administration of antipsychotics in general can improve source-monitoring deficits. The neuropsychiatric perspective provides a more accurate and comprehensive understanding of schizophrenia.

  20. Error monitoring and empathy: Explorations within a neurophysiological context.

    PubMed

    Amiruddin, Azhani; Fueggle, Simone N; Nguyen, An T; Gignac, Gilles E; Clunies-Ross, Karen L; Fox, Allison M

    2017-06-01

    Past literature has proposed that empathy consists of two components: cognitive and affective empathy. Error monitoring mechanisms indexed by the error-related negativity (ERN) have been associated with empathy. Studies have found that a larger ERN is associated with higher levels of empathy. We aimed to expand upon previous work by investigating how error monitoring relates to the independent theoretical domains of cognitive and affective empathy. Study 1 (N = 24) explored the relationship between error monitoring mechanisms and subcomponents of empathy using the Questionnaire of Cognitive and Affective Empathy and found no relationship. Study 2 (N = 38) explored the relationship between the error monitoring mechanisms and overall empathy. Contrary to past findings, there was no evidence to support a relationship between error monitoring mechanisms and scores on empathy measures. A subsequent meta-analysis (Study 3, N = 125) summarizing the relationship across previously published studies together with the two studies reported in the current paper indicated that overall there was no significant association between ERN and empathy and that there was significant heterogeneity across studies. Future investigations exploring the potential variables that may moderate these relationships are discussed. © 2017 Society for Psychophysiological Research.

  1. The effect of parental monitoring on trajectories of disordered eating attitudes and behaviors among adolescents: An individual growth curve analysis.

    PubMed

    Martinson, Laura E; Esposito-Smythers, Christianne; Blalock, Dan V

    2016-12-01

    The primary aim of the present study was to examine whether parental monitoring, as reported by adolescents and their parents, predicts more or less favorable trajectories of disordered eating behavior and attitudes over the course of one year in a sample of adolescent males and females. An additional aim was to explore whether these trajectories vary when study analyses are limited to females. Participants included 87 adolescents (mean age = 15.5 ± 1.4) in mental health treatment and their parents. Self-report measures included the Parental Monitoring Questionnaire, completed at baseline, and the Eating Attitudes Test-Dieting Subscale, completed at baseline as well as 6-month and 12-month follow-ups. Individual growth curve (IGC) analyses were used to examine change in disordered eating behavior and attitudes. Adolescents who reported lower parental monitoring showed trajectories characterized by increases in disordered eating attitudes and behaviors. The same pattern emerged when using parent report of monitoring, though only a trend was evident. When analyses were restricted to females, the main effect of parental and adolescent report of monitoring on disordered eating were equally strong. Results may suggest that parents who are less knowledgeable about their adolescents' daily lives, may be less aware of potential disordered eating attitudes and behaviors, and thus less likely to intervene. Findings could be used to inform family-based interventions for this population. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. BLM Unmanned Aircraft Systems (UAS) Resource Management Operations

    NASA Astrophysics Data System (ADS)

    Hatfield, M. C.; Breen, A. L.; Thurau, R.

    2016-12-01

    The Department of the Interior Bureau of Land Management is funding research at the University of Alaska Fairbanks to study Unmanned Aircraft Systems (UAS) Resource Management Operations. In August 2015, the team conducted flight research at UAF's Toolik Field Station (TFS). The purpose was to determine the most efficient use of small UAS to collect low-altitude airborne digital stereo images, process the stereo imagery into close-range photogrammetry products, and integrate derived imagery products into the BLM's National Assessment, Inventory and Monitoring (AIM) Strategy. The AIM Strategy assists managers in answering questions of land resources at all organizational levels and develop management policy at regional and national levels. In Alaska, the BLM began to implement its AIM strategy in the National Petroleum Reserve-Alaska (NPR-A) in 2012. The primary goals of AIM-monitoring at the NPR-A are to implement an ecological baseline to monitor ecological trends, and to develop a monitoring network to understand the efficacy of management decisions. The long-term AIM strategy also complements other ongoing NPR-A monitoring processes, collects multi-use and multi-temporal data, and supports understanding of ecosystem management strategies in order to implement defensible natural resource management policy. The campaign measured vegetation types found in the NPR-A, using UAF's TFS location as a convenient proxy. The vehicle selected was the ACUASI Ptarmigan, a small hexacopter (based on DJI S800 airframe and 3DR autopilot) capable of carrying a 1.5 kg payload for 15 min for close-range environmental monitoring missions. The payload was a stereo camera system consisting of Sony NEX7's with various lens configurations (16/20/24/35 mm). A total of 77 flights were conducted over a 4 ½ day period, with 1.5 TB of data collected. Mission variables included camera height, UAS speed, transect overlaps, and camera lenses/settings. Invaluable knowledge was gained as to limitations and opportunities for field deployment of UAS relative to local conditions and vegetation type. Future efforts will focus of refining data analysis techniques and further optimizing UAS/sensor combinations and flight profiles.

  3. Rule Based Expert System for Monitoring Real Time Drug Supply in Hospital Using Radio Frequency Identification Technology

    NASA Astrophysics Data System (ADS)

    Driandanu, Galih; Surarso, Bayu; Suryono

    2018-02-01

    A radio frequency identification (RFID) has obtained increasing attention with the emergence of various applications. This study aims to examine the implementation of rule based expert system supported by RFID technology into a monitoring information system of drug supply in a hospital. This research facilitates in monitoring the real time drug supply by using data sample from the hospital pharmacy. This system able to identify and count the number of drug and provide warning and report in real time. the conclusion is the rule based expert system and RFID technology can facilitate the performance in monitoring the drug supply quickly and precisely.

  4. Effects of Parental Monitoring and Exposure to Community Violence on Antisocial Behavior and Anxiety/Depression among Adolescents

    ERIC Educational Resources Information Center

    Bacchini, Dario; Miranda, Maria Concetta; Affuso, Gaetana

    2011-01-01

    The aim of the research was to investigate the influence of gender, exposure to community violence, and parental monitoring upon antisocial behavior and anxiety/depression in adolescence. Involved in the study were 489 adolescents (290 males and 189 females) from 4 secondary schools in the city of Naples, Italy. The age of participants ranged from…

  5. A systematic review of near-infrared spectroscopy in flap monitoring: Current basic and clinical evidence and prospects.

    PubMed

    Kagaya, Yu; Miyamoto, Shimpei

    2018-02-01

    Near-infrared spectroscopy (NIRS) has been reported to be a reliable non-invasive modality for free flap monitoring; however, the history of its application in flap monitoring is short, and there is no definite consensus regarding its use at present. The aim of this review is to clarify the evidence related to post-operative flap monitoring using NIRS and examine its appropriateness and usability. The PubMed and Web of Science databases were searched using the strings "flap monitoring AND near-infrared spectroscopy" and "flap monitoring AND tissue oxygen saturation," with a study period from inception to December 31, 2016. Two authors independently extracted articles and assessed the quality of the studies. Articles related to NIRS for flap perfusion monitoring were classified and selected regardless of study type. A total of 15 clinical studies and 8 animal studies were identified and reviewed. The evidence and information on various aspects of NIRS flap monitoring were summarized. The overall flap success rate was 99.5%, and the flap salvage rate was 91.1%, when measuring StO 2 at intervals of every 2 h or sooner. Single StO 2 monitoring was able to detect vascular compromise with 99.1% sensitivity and 99.9% specificity, and earlier than other monitoring methods, but additional Hb concentration monitoring was useful for avoiding false negatives and differentiating arterial and venous occlusion. NIRS can be used for flap monitoring and displays high accuracy in various situations; however, further studies are needed to take full advantage of the potential of NIRS. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  6. Historical Building Stability Monitoring by Means of a Cosmic Ray Tracking System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zenoni, Aldo; INFN Sezione di Pavia, Via Bassi 6, 27100 Pavia

    Cosmic ray radiation is mostly composed, at sea level, by high energy muons, which are highly penetrating particles capable of crossing kilometers of rock. The ubiquitous and steady presence at the Earth's surface and the high penetration capability have motivated the use of cosmic ray radiation also in fields beyond particle physics, from geology, archaeology, speleology to industrial applications and homeland security. In particular, in recent years, the novel technique of muon tomography has been proposed, with the aim of performing non invasive inspection of large non accessible volumes, material atomic number Z and density discrimination, and three dimension imagemore » reconstruction of the inspected volume. In the present paper, after a short recall of the physical principles and mathematical formalism on which muon tomography is based, a number of examples of application of the novel technique in industry and homeland security issues is given. Moreover, a new application of cosmic rays detection techniques in the field of civil engineering is proposed. The aim is the monitoring of the stability of large structures, in particular the static monitoring of historical buildings, where conservation constraints are more severe and the time evolution of the deformation phenomena under study may be of the order of months or years. The new technique may be seen, in some way, as the reverse problem of muon tomography. As a significant case study, the monitoring of the wooden vaulted roof of the Palazzo della Loggia in the town of Brescia, in Italy, has been considered. The feasibility as well as the performances and limitations of a monitoring system based on cosmic ray tracking have been studied by Monte Carlo simulation and discussed in comparison with more traditional monitoring systems. (authors)« less

  7. Wireless non-invasive continuous respiratory monitoring with FMCW radar: a clinical validation study.

    PubMed

    van Loon, K; Breteler, M J M; van Wolfwinkel, L; Rheineck Leyssius, A T; Kossen, S; Kalkman, C J; van Zaane, B; Peelen, L M

    2016-12-01

    Altered respiratory rate is one of the first symptoms of medical conditions that require timely intervention, e.g., sepsis or opioid-induced respiratory depression. To facilitate continuous respiratory rate monitoring on general hospital wards a contactless, non-invasive, prototype monitor was developed using frequency modulated continuous wave radar. We aimed to study whether radar can reliably measure respiratory rate in postoperative patients. In a diagnostic cross-sectional study patients were monitored with the radar and the reference monitor (pneumotachograph during mechanical ventilation and capnography during spontaneous breathing). Eight patients were included; yielding 796 min of observation time during mechanical ventilation and 521 min during spontaneous breathing. After elimination of movement artifacts the bias and 95 % limits of agreement for mechanical ventilation and spontaneous breathing were -0.12 (-1.76 to 1.51) and -0.59 (-5.82 to 4.63) breaths per minute respectively. The radar was able to accurately measure respiratory rate in mechanically ventilated patients, but the accuracy decreased during spontaneous breathing.

  8. Knowledge and practices of pre-school teachers on growth monitoring program—South Africa

    PubMed Central

    Mandiwana, Tshifhiwa Cynthia; Mbhenyane, Xikombiso G.; Mushaphi, Lindelani Fhumudzani; Mabapa, Ngoako Solomon

    2015-01-01

    The aim of this study was to determine knowledge and practices of pre-school teachers on growth monitoring. A quasi-experimental, one-group pre- and post-test intervention study was conducted in eight conveniently selected government subsidized pre-schools in Vhembe and Mopani districts of Limpopo Province, South Africa. Fifteen pre-school teachers participated in the study. An intervention in a form of nutrition education lessons on growth monitoring was developed and implemented. Pre-school teachers completed a knowledge test questionnaire prior to the lessons. The intervention also included the following training skills: procedure to take anthropometric measurements and plotting the Road to Health Chart. About 67% teachers understood the importance of growth monitoring at baseline. The results also showed an improvement 6 months after intervention. All (100%) teachers knew that growth monitoring can be used for diagnosing undernutrition. The results also showed an improvement in skills, such as the procedure to take anthropometric measurements. Knowledge and practices of teachers on growth monitoring were improved by nutrition education 6 months after intervention. PMID:25296726

  9. Recommendations for data monitoring committees from the Clinical Trials Transformation Initiative.

    PubMed

    Calis, Karim A; Archdeacon, Patrick; Bain, Raymond; DeMets, David; Donohue, Miriam; Elzarrad, M Khair; Forrest, Annemarie; McEachern, John; Pencina, Michael J; Perlmutter, Jane; Lewis, Roger J

    2017-08-01

    Background/aims Use of data monitoring committees to oversee clinical trials was first proposed nearly 50 years ago. Since then, data monitoring committee use in clinical trials has increased and evolved. Nonetheless, there are no well-defined criteria for determining the need for a data monitoring committee, and considerable variability exists in data monitoring committee composition and conduct. To understand and describe the role and function of data monitoring committees, and establish best practices for data monitoring committee trial oversight, the Clinical Trials Transformation Initiative-a public-private partnership to improve clinical trials-launched a multi-stakeholder project. Methods The data monitoring committee project team included 16 individuals charged with (1) clarifying the purpose of data monitoring committees, (2) identifying best practices for independent data monitoring committee conduct, (3) describing effective communication practices, and (4) developing strategies for training data monitoring committee members. Evidence gathering included a survey, a series of focus group discussions, and a 2-day expert meeting aimed at achieving consensus opinions that form the foundation of our data monitoring committee recommendations. Results We define the role of the data monitoring committee as an advisor to the research sponsor on whether to continue, modify, or terminate a trial based on periodic assessment of trial data. Data monitoring committees should remain independent from the sponsor and be composed of members with no relevant conflicts of interest. Representation on a data monitoring committee generally should include at least one clinician with expertise in the therapeutic area being studied, a biostatistician, and a designated chairperson who has experience with clinical trials and data monitoring. Data monitoring committee meetings are held periodically to evaluate the unmasked data from ongoing trials, but the content and conduct of meetings may vary depending on specific goals or topics for deliberation. To guide data monitoring committee conduct and communication plans, a charter consistent with the protocol's research design and statistical analysis plan should be developed and agreed upon by the sponsor and the data monitoring committee prior to patient enrollment. We recommend concise and flexible charters that explain roles, responsibilities, operational issues, and how data monitoring committee recommendations are generated and communicated. The demand for data monitoring committee members appears to exceed the current pool of qualified individuals. To prepare a new generation of trained data monitoring committee members, we encourage a combination of didactic educational programs, practical experience, and skill development through apprenticeships and mentoring by experienced data monitoring committee members. Conclusion Our recommendations address data monitoring committee use, conduct, communication practices, and member preparation and training. Furthermore recommendations form the foundation for ongoing efforts to improve clinical trial oversight and enhance the safety and integrity of clinical research. These recommendations serve as a call to action for implementation of best practices that benefit study participants, study sponsors, and society.

  10. Patient attitudes towards remote continuous vital signs monitoring on general surgery wards: An interview study.

    PubMed

    Downey, C L; Brown, J M; Jayne, D G; Randell, R

    2018-06-01

    Vital signs monitoring is used to identify deteriorating patients in hospital. The most common tool for vital signs monitoring is an early warning score, although emerging technologies allow for remote, continuous patient monitoring. A number of reviews have examined the impact of continuous monitoring on patient outcomes, but little is known about the patient experience. This study aims to discover what patients think of monitoring in hospital, with a particular emphasis on intermittent early warning scores versus remote continuous monitoring, in order to inform future implementations of continuous monitoring technology. Semi-structured interviews were undertaken with 12 surgical inpatients as part of a study testing a remote continuous monitoring device. All patients were monitored with both an early warning score and the new device. Interviews were audio-recorded, transcribed verbatim and analysed using thematic analysis. Patients can see the value in remote, continuous monitoring, particularly overnight. However, patients appreciate the face-to-face aspect of early warning score monitoring as it allows for reassurance, social interaction, and gives them further opportunity to ask questions about their medical care. Early warning score systems are widely used to facilitate detection of the deteriorating patient. Continuous monitoring technologies may provide added reassurance. However, patients value personal contact with their healthcare professionals and remote monitoring should not replace this. We suggest that remote monitoring is best introduced in a phased manner, and initially as an adjunct to usual care, with careful consideration of the patient experience throughout. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Leisure time activities, parental monitoring and drunkenness in adolescents.

    PubMed

    Tomcikova, Zuzana; Veselska, Zuzana; Madarasova Geckova, Andrea; van Dijk, Jitse P; Reijneveld, Sijmen A

    2013-01-01

    The aim of this cross-sectional study was to explore the association between adolescent drunkenness and participation in risky leisure time activities and parental monitoring. A sample of 3,694 Slovak elementary school students (mean age 14.5 years; 49.0% males) was assessed for drunkenness in the previous month, participation in risky leisure activities and parental monitoring. Participation in risky leisure time activities increased the probability of drunkenness among adolescents, while parental monitoring decreased it. The effect did not change after adding the mother's and father's monitoring into the models. Our results imply that adolescents involved in going out with friends, having parties with friends and/or visiting sporting events every day or several times a week are at a higher risk of drunkenness, as are those less monitored by their parents. These less monitored adolescents and their parents should become a target group in prevention. Copyright © 2012 S. Karger AG, Basel.

  12. Women's experiences of continuous fetal monitoring - a mixed-methods systematic review.

    PubMed

    Crawford, Alexandra; Hayes, Dexter; Johnstone, Edward D; Heazell, Alexander E P

    2017-12-01

    Antepartum stillbirth is often preceded by detectable signs of fetal compromise, including changes in fetal heart rate and movement. It is hypothesized that continuous fetal monitoring could detect these signs more accurately and objectively than current forms of fetal monitoring and allow for timely intervention. This systematic review aimed to explore available evidence on women's experiences of continuous fetal monitoring to investigate its acceptability before clinical implementation and to inform clinical studies. Systematic searching of four electronic databases (Embase, PsycINFO, MEDLINE and CINAHL), using key terms defined by initial scoping searches, identified a total of 35 studies. Following title and abstract screening by two independent researchers, five studies met the inclusion criteria. Studies were not excluded based on language, methodology or quality assessment. An integrative methodology was used to synthesize qualitative and quantitative data together. Forms of continuous fetal monitoring used included Monica AN24 monitors (n = 4) and phonocardiography (n = 1). Four main themes were identified: practical limitations of the device, negative emotions, positive perceptions, and device implementation. Continuous fetal monitoring was reported to have high levels of participant satisfaction and was preferred by women to intermittent cardiotocography. This review suggests that continuous fetal monitoring is accepted by women. However, it has also highlighted both the paucity and heterogeneity of current studies and suggests that further research should be conducted into women's experiences of continuous fetal monitoring before such devices can be used clinically. © 2017 Nordic Federation of Societies of Obstetrics and Gynecology.

  13. Effect of quality metric monitoring and colonoscopy performance.

    PubMed

    Razzak, Anthony; Smith, Dineen; Zahid, Maliha; Papachristou, Georgios; Khalid, Asif

    2016-10-01

    Background and aims: Adenoma detection rate (ADR) and cecal withdrawal time (CWT) have been identified as measures of colonoscopy quality. This study evaluates the impact of monitoring these measures on provider performance. Methods: Six blinded gastroenterologists practicing at a Veterans Affairs Medical Center were prospectively monitored over 9 months. Data for screening, adenoma surveillance, and fecal occult blood test positive (FOBT +) indicated colonoscopies were obtained, including exam preparation quality, cecal intubation rate, CWT, ADR, adenomas per colonoscopy (APC), and adverse events. Metrics were continuously monitored after a period of informed CWT monitoring and informed CWT + ADR monitoring. The primary outcome was impact on ADR and APC. Results: A total of 1671 colonoscopies were performed during the study period with 540 before informed monitoring, 528 during informed CWT monitoring, and 603 during informed CWT + ADR monitoring. No statistically significant impact on ADR was noted across each study phase. Multivariate regression revealed a trend towards fewer adenomas removed during the CWT monitoring phase (OR = 0.79; 95 %CI 0.62 - 1.02, P  = 0.065) and a trend towards more adenomas removed during the CWT + ADR monitoring phase when compared to baseline (OR = 1.26; 95 %CI 0.99 - 1.61, P  = 0.062). Indication for examination and provider were significant predictors for higher APC. Provider-specific data demonstrated a direct relationship between high ADR performers and increased CWT. Conclusions: Monitoring quality metrics did not significantly alter colonoscopy performance across a small heterogeneous group of providers. Non-significant trends towards higher APC were noted with CWT + ADR monitoring. Providers with a longer CWT had a higher ADR. Further studies are needed to determine the impact of monitoring on colonoscopy performance.

  14. Project monitoring and evaluation: an enhancing method for health research system management.

    PubMed

    Djalalinia, Shirin; Owlia, Parviz; Malekafzali, Hossein; Ghanei, Mostafa; Babamahmoodi, Abdolreza; Peykari, Niloofar

    2014-04-01

    Planning, organizing, staffing, leading and monitoring are the basic functional component of management. In present article, we aim to define the project monitoring and evaluation in health research system (HRS) considering its success and challenges based on our national experience. IN THIS STUDY BASED ON THE INFORMATION OF ANNUAL MEDICAL SCIENCE UNIVERSITIES EVALUATION DURING THE LAST DECADE THE HRS INDICATORS HAVE BEEN SCORED IN THREE AXES BASED ON HRS FUNCTIONS: Stewardship, capacity building and knowledge production. In this article, we will focus on the results of HRS evaluation from 2002 to 2010, also on its success and challenges. In an overall view, the main results are the experiences of the designing and implantation of such process after pre-project preparation, all parts followed under the whole supervision of the aims of the HRS evaluation. Project management light the way of practical application of knowledge, skills, tools and techniques for better HRS evaluation and management. We concluded that; although monitoring and evaluation as an essential part of HRS Management light the improvement ahead way but we still need to advantage of the new project management advances.

  15. IMS radionuclide monitoring after the announced nuclear test of the DPRK on 3 September 2017

    NASA Astrophysics Data System (ADS)

    Kusmierczyk-Michulec, J.; Kalinowski, M.; Bourgouin, P.; Boxue, L.; Gheddou, A.; Klingberg, F.; Leppaenen, A. P.; Schoeppner, M.; Werzi, R.; Wang, J.

    2017-12-01

    The International Monitoring System (IMS) developed by the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) is a global system of monitoring stations, using four complementary technologies: seismic, hydroacoustic, infrasound and radionuclide. The radionuclide network comprises 80 stations, out of which 40 are to be equipped with noble gas systems. The aim of radionuclide stations is a global monitoring of radioactive aerosols, radioactive noble gases and atmospheric transport modelling (ATM). To investigate the transport of radionuclide emissions, the Provisional Technical Secretariat (PTS) operates an Atmospheric Transport Modelling (ATM) system based on the Lagrangian Particle Dispersion Model FLEXPART. The air mass trajectory provides a "link" between a radionuclide release and a detection confirmed by radionuclide measurements. The aim of this study is to demonstrate the RN analysis and the application of ATM to investigate the episodes of elevated levels of radioxenon observed by IMS stations after the sixth nuclear test, announced by the Democratic People's Republic of Korea (DPRK) at the Punggye-ri Nuclear Test Site on 3 September 2017. A comparison to the previous tests will be presented.

  16. A participatory approach to design monitoring indicators of production diseases in organic dairy farms.

    PubMed

    Duval, J E; Fourichon, C; Madouasse, A; Sjöström, K; Emanuelson, U; Bareille, N

    2016-06-01

    Production diseases have an important negative effect on the health and welfare of dairy cows. Although organic animal production systems aim for high animal health levels, compliance with European organic farming regulations does not guarantee that this is achieved. Herd health and production management (HHPM) programs aim at optimizing herd health by preventing disease and production problems, but as yet they have not been consistently implemented by farmers. We hypothesize that one reason is the mismatch between what scientists propose as indicators for herd health monitoring and what farmers would like to use. Herd health monitoring is a key element in HHPM programs as it permits a regular assessment of the functioning of the different components of the production process. Planned observations or measurements of these components are indispensable for this monitoring. In this study, a participatory approach was used to create an environment in which farmers could adapt the indicators proposed by scientists for monitoring the five main production diseases on dairy cattle farms. The adaptations of the indicators were characterized and the farmers' explanations for the changes made were described. The study was conducted in France and Sweden, which differ in terms of their national organic regulations and existing advisory services. In both countries, twenty certified organic dairy farmers and their animal health management advisors participated in the study. All of the farmers adapted the initial monitoring plan proposed by scientists to specific production and animal health situation on their farm. This resulted in forty unique and farm-specific combinations of indicators for herd health monitoring. All but three farmers intended to monitor five health topics simultaneously using the constructed indicators. The qualitative analysis of the explanations given by farmers for their choices enabled an understanding of farmers' reasons for selecting and adapting indicators. This is valuable information for scientists involved in the design of HHPM programs. Advisors in the field also can benefit from this participatory approach because it transforms monitoring tools provided by scientists into farm-specific tools. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Validation of a metered dose inhaler electronic monitoring device: implications for asthma clinical trial use.

    PubMed

    Pilcher, Janine; Holliday, Mark; Ebmeier, Stefan; McKinstry, Steve; Messaoudi, Fatiha; Weatherall, Mark; Beasley, Richard

    2016-01-01

    The SmartTouch Ventolin monitor (Adherium, Auckland, New Zealand) is an electronic monitor for use with a Ventolin metered dose inhaler, which records the date and time of inhaler actuations. This technology has the potential to allow in-depth analysis of patterns of inhaler use in clinical trial settings. The aim of this study was to determine the accuracy of the SmartTouch Ventolin monitor in recording Ventolin actuations. 20 SmartTouch Ventolin monitors were attached to Ventolin metered dose inhalers. Bench testing was performed over a 10-week period, to reflect the potential time frame between visits in a clinical trial. Inhaler actuations were recorded in a paper diary, which was compared with data uploaded from the monitors. 2560 actuations were performed during the 10-week study period. Monitor sensitivity for diary-recorded actuations was 99.9% with a lower 97.5% confidence bound of 99.7%. The positive predictive value for diary-recorded actuations was 100% with a 97.5% lower confidence bound of 99.9%. The SmartTouch Ventolin monitor is highly accurate in recording and retaining electronic data. It can be recommended for use in clinical trial settings in which training and quality control systems are incorporated into study protocols to ensure accurate data acquisition.

  18. Validation of a metered dose inhaler electronic monitoring device: implications for asthma clinical trial use

    PubMed Central

    Pilcher, Janine; Holliday, Mark; Ebmeier, Stefan; McKinstry, Steve; Messaoudi, Fatiha; Weatherall, Mark; Beasley, Richard

    2016-01-01

    Background The SmartTouch Ventolin monitor (Adherium, Auckland, New Zealand) is an electronic monitor for use with a Ventolin metered dose inhaler, which records the date and time of inhaler actuations. This technology has the potential to allow in-depth analysis of patterns of inhaler use in clinical trial settings. The aim of this study was to determine the accuracy of the SmartTouch Ventolin monitor in recording Ventolin actuations. Methods 20 SmartTouch Ventolin monitors were attached to Ventolin metered dose inhalers. Bench testing was performed over a 10-week period, to reflect the potential time frame between visits in a clinical trial. Inhaler actuations were recorded in a paper diary, which was compared with data uploaded from the monitors. Results 2560 actuations were performed during the 10-week study period. Monitor sensitivity for diary-recorded actuations was 99.9% with a lower 97.5% confidence bound of 99.7%. The positive predictive value for diary-recorded actuations was 100% with a 97.5% lower confidence bound of 99.9%. Conclusions The SmartTouch Ventolin monitor is highly accurate in recording and retaining electronic data. It can be recommended for use in clinical trial settings in which training and quality control systems are incorporated into study protocols to ensure accurate data acquisition. PMID:27026805

  19. [Health monitoring units in Bavaria. Concept, aims and thematic focus of the first survey on children's environment and health].

    PubMed

    Bolte, G; Heissenhuber, A; von Kries, R; Liebl, B; Zapf, A; Wildner, M; Fromme, H

    2007-04-01

    Starting in 2004, health monitoring units (GME) were established in three rural and three urban regions of the federal state Bavaria, Germany. The GME s aim is to gain current and relevant health data especially of children in Bavaria and to evaluate health promotion and prevention strategies. The first survey 2004/2005 was a cross-sectional study of the environmental health of children aged 5 to 7 years. There are data available from 3030 girls and 3319 boys (response rate 78%). This paper describes the study regions and the sociodemographic characteristics of the study population which differed substantially between urban and rural regions. The thematic focus of the survey was: (1) Social disparities in housing conditions, related environmental exposures, and children's health, (2) accidents and injuries, (3) environmental tobacco smoke exposure of children and precautionary measures of their parents, (4) nutrition, physical activity and obesity, and (5) temporal trends of the prevalence of asthma and allergies. The insights gained within the health monitoring units will contribute to the identification and quantification of health risks as well as to the establishment of intervention strategies with special focus on the needs of the public health service.

  20. The environmental monitoring of Cultural Heritage through Low Cost strategies: The frescoes of the crypt of St. Francesco d'Assisi's, Irsina (Basilicata, Southern Italy)

    NASA Astrophysics Data System (ADS)

    Sileo, Maria; Gizzi, Fabrizio; Masini, Nicola

    2015-04-01

    One of the main tools of assessment and diagnosis used to define appropriate strategies for the preservation of cultural heritage is the environmental monitoring. To achieve an environmental monitoring are needed high costs of purchase and maintenance, high costs of instrumental and for the management of the plants and processing of results. These costs imply that the technologies for environmental monitoring are not as common but their use is limited to the study very famous monuments or sites. To extend the use and dissemination of such technologies to a greater number of monuments, through the project Pro_Cult (Advanced methodological approaches and technologies for Protection and Security of Cultural Heritage) a research aimed at testing low cost technologies has been performed. The aim of the research is to develop low cost monitoring systems, assessing their effectiveness in a comparative way with commercial high cost ones. To this aim an environmental monitoring system using the Arduino system was designed and developed. It is an electronics prototyping platform based on open-source hardware and software flexible and user friendly. This system is connected to sensors for the detection of environmental parameters of non high purchase cost but with respect to the medium potential detection sensors accurately. This low cost system was tested in the framework of a microclimate monitoring project of the crypt of St. Francis of Assisi in Irsina (Southern Italy) enriched by a precious cycle of medieval frescoes. The aim of this research was to compare two monitoring systems, the first, at low cost, using Arduino system, and the second, a standard commercial product for a full yearly cycle and assess the reliability and the results obtained by the two systems. This paper shows the results of the comparative analysis of an entire monitoring yearly cycle in relation to the problems of degradation affecting the paintings of medieval crypt [1]. The obtained results proved the capability and reliability of the designed low cost monitoring system for investigating the indoor microclimate in relation with decay pathologies. Acknowledgements The authors thank Basilicata Region for supporting this activity in the framework of the Project "PRO_CULT" (Advanced methodological approaches and technologies for Protection and Security of Cultural Heritage) financed by Regional Operational Programme ERDF 2007/2013 [1] M. Sileo, M. Biscione, F.T. Gizzi, N. Masini & M.I. Martinez-Garrido, 2014 - Low cost strategies for the environmental monitoring of Cultural Heritage: Preliminary data from the crypt of St. Francesco d'Assisi, Irsina (Basilicata, Southern Italy). Science, Technology and Cultural Heritage, Edited by Miguel Angel Rogerio-Candelera, 27-34. ISBN: 978-1-138-02744-2.

  1. Environmental monitoring in interventional radiology

    NASA Astrophysics Data System (ADS)

    Del Sol, S.; Garcia, R.; Sánchez-Guzmán, D.; Ramirez, G.; Chavarin, E. U.; Rivera, T.

    2017-01-01

    The procedures in Interventional Radiology involve long times of exposure and high number of radiographic images that bring higher radiation doses to patients, staff and environmental than those received in conventional Radiology. Currently for monitoring the dose, the thermoluminescent dosimetry use is recommended. The aim of this work was to carry out the monitoring of the environmental scattered radiation inside the IR room using two types of thermoluminescent dosimeters, TLD-100 (reference dosimeter), CaSO4:Dy (synthesized in our laboratory). The results indicate that the TLD-100 is not effective for the environmental monitoring of low-energy Rx rooms. The CaSO4:Dy presented good behaviour over the 6 months of study. The results will be specific to each room so it is recommended such studies as part of the program of quality control of each Rx room.

  2. A prospective pilot study of home monitoring in adults with cystic fibrosis (HOME-CF): protocol for a randomised controlled trial.

    PubMed

    Choyce, Jocelyn; Shaw, Karen L; Sitch, Alice J; Mistry, Hema; Whitehouse, Joanna L; Nash, Edward F

    2017-01-23

    Home monitoring has the potential to detect early pulmonary exacerbations in people with cystic fibrosis (CF), with consequent improvements in health outcomes and healthcare associated costs. This study aims to assess the effects of home monitoring on hospital admissions, quality of life, antibiotic requirements, exacerbation frequency, lung function, nutritional outcomes, anxiety, depression, costs and health outcomes, as well as the qualitative effects on the patient experience. This randomised controlled mixed-methods trial aims to recruit 100 adults with CF cared for in one large regional CF centre. Participants are randomly allocated 1:1 to the intervention group (twice-weekly home monitoring of symptoms measured by the Cystic Fibrosis Respiratory Symptom Diary - Chronic Respiratory Infection Symptom Score (CFRSD-CRISS) and Forced Expiratory Volume in one second (FEV 1 )) or a control group (routine clinical care) for the 12-month study period. Measurements are recorded at study visits at baseline, 3, 6, 9 and 12 months. Spirometry, body weight, co-morbidities, medications, hospital inpatient days, courses of antibiotics (oral and intravenous), pulmonary exacerbations (defined by the modified Fuchs criteria) are recorded at each study visit. Health status, capability and health economics are measured at each study visit by the Hospital Anxiety and Depression Scale (HADS), the ICEpop CAPability measure for Adults (ICECAP-A), EuroQol 5 dimensions (EQ-5D-5L) questionnaire and an adapted resource use questionnaire. The patient experience is assessed by semi-structured qualitative interviews at baseline and 12 months. Results from this study will help to determine the effect of home monitoring on inpatient bed days and quality of life in adults with CF, as well as other relevant health and health economic outcomes. This study protocol is registered with Clinicaltrials.gov ( NCT02994706 ), date registered 16 th July 2014.

  3. Monitoring long-term oral corticosteroids

    PubMed Central

    Mundell, Lewis; Lindemann, Roberta; Douglas, James

    2017-01-01

    Corticosteroids are synthetic analogues of human hormones normally produced by the adrenal cortex. They have both glucocorticoid and mineralocorticoid properties. The glucocortoid components are anti-inflammatory, immunosuppressive, anti-proliferative and vasoconstrictive. They influence the metabolism of carbohydrate and protein, in addition to playing a key role in the body’s stress response. Mineralocorticoid’s main significance is in the balance of salt and water concentrations. Due to the combination of these effects, corticosteroids can cause many adverse effects. Oral corticosteroids are absorbed systemically and are therefore more likely to cause adverse effects than topical or inhaled corticosteroids. Furthermore, it is assumed that greater duration of treatment will lead to a greater number of adverse effects, and therefore the most at risk group are those taking high dose, long-term oral corticosteroids (LTOC). High dose is defined as a prescription of >5 mg oral prednisolone and long term as duration of treatment >1 month (based on National Institute for Health and Care Excellence guidance for patient’s ’at risk' of systemic side effects). Parameters to be monitored in primary care include weight, blood pressure, triglycerides, glucose and urea and electrolytes. From clinical experience within the general practice setting, the authors propose that these patients do not receive adequate baseline monitoring before starting corticosteroids nor are these markers monitored consistently thereafter. This project intended to evidence this claim, evaluate the adverse effect profile and improve monitoring in this patient group. The initial audit of 22 patients, within a single general practice, detected at least one documented adverse effect in 64% of patients, while 41% reported more than one adverse effect. 45% had recorded weight gain, 18% had recorded osteoporosis, 18% had at least one recorded cataract, 14% had recorded Hypertension, 14% had recorded diabetes mellitus, 9% had recorded dyspepsia and 5% had a recorded psychiatric complaint. All of these recorded conditions were either directly attributed to steroid medication or occurred since LTOC were prescribed. The aim of this project was to increase the percentage of patients on LTOC with complete baseline monitoring to 100%. ’Baseline monitoring' was defined as a measurement taken within the previous 5 years. Although somewhat arbitrary, 5 years was felt to be the maximum timeframe in which monitoring would still be relevant for comparison following introduction of LTOC. Quality improvement methodology was used throughout this project with multiple PDSA (Plan, Study, Do and Act) cycles. Through this, a monitoring system and protocol for patients taking LTOC was developed. As a result of this project, five adverse effects were detected in five different patients. These included two cases of secondary hypertension, one case of diabetes mellitus, one cataract and one case of adrenal insufficiency. 12 out of 20 patients achieved complete baseline monitoring. While this study did not fully achieve its aim, the aim was deliberately ambitious. As not all patients in this study attended for monitoring, a figure of 100% was impossible to achieve. The remaining ’incompletely monitored patients' had some but not all parameters measured. The creation of a staff protocol and increased clinical experience will ensure that complete monitoring takes place in the future. In conclusion, this project has shown that adverse effects from LTOC are prevalent in a single general practice population. It is also shown that monitoring for LTOC adverse effects is inadequate but can be improved relatively easily as skills and competencies from other medication monitoring systems already exist within healthcare settings and are immediately transferable. PMID:29450303

  4. Monitoring long-term oral corticosteroids.

    PubMed

    Mundell, Lewis; Lindemann, Roberta; Douglas, James

    2017-01-01

    Corticosteroids are synthetic analogues of human hormones normally produced by the adrenal cortex. They have both glucocorticoid and mineralocorticoid properties. The glucocortoid components are anti-inflammatory, immunosuppressive, anti-proliferative and vasoconstrictive. They influence the metabolism of carbohydrate and protein, in addition to playing a key role in the body's stress response. Mineralocorticoid's main significance is in the balance of salt and water concentrations. Due to the combination of these effects, corticosteroids can cause many adverse effects. Oral corticosteroids are absorbed systemically and are therefore more likely to cause adverse effects than topical or inhaled corticosteroids. Furthermore, it is assumed that greater duration of treatment will lead to a greater number of adverse effects, and therefore the most at risk group are those taking high dose, long-term oral corticosteroids (LTOC). High dose is defined as a prescription of >5 mg oral prednisolone and long term as duration of treatment >1 month (based on National Institute for Health and Care Excellence guidance for patient's 'at risk' of systemic side effects). Parameters to be monitored in primary care include weight, blood pressure, triglycerides, glucose and urea and electrolytes. From clinical experience within the general practice setting, the authors propose that these patients do not receive adequate baseline monitoring before starting corticosteroids nor are these markers monitored consistently thereafter. This project intended to evidence this claim, evaluate the adverse effect profile and improve monitoring in this patient group. The initial audit of 22 patients, within a single general practice, detected at least one documented adverse effect in 64% of patients, while 41% reported more than one adverse effect. 45% had recorded weight gain, 18% had recorded osteoporosis, 18% had at least one recorded cataract, 14% had recorded Hypertension, 14% had recorded diabetes mellitus, 9% had recorded dyspepsia and 5% had a recorded psychiatric complaint. All of these recorded conditions were either directly attributed to steroid medication or occurred since LTOC were prescribed. The aim of this project was to increase the percentage of patients on LTOC with complete baseline monitoring to 100%. 'Baseline monitoring' was defined as a measurement taken within the previous 5 years. Although somewhat arbitrary, 5 years was felt to be the maximum timeframe in which monitoring would still be relevant for comparison following introduction of LTOC. Quality improvement methodology was used throughout this project with multiple PDSA (Plan, Study, Do and Act) cycles. Through this, a monitoring system and protocol for patients taking LTOC was developed. As a result of this project, five adverse effects were detected in five different patients. These included two cases of secondary hypertension, one case of diabetes mellitus, one cataract and one case of adrenal insufficiency. 12 out of 20 patients achieved complete baseline monitoring. While this study did not fully achieve its aim, the aim was deliberately ambitious. As not all patients in this study attended for monitoring, a figure of 100% was impossible to achieve. The remaining 'incompletely monitored patients' had some but not all parameters measured. The creation of a staff protocol and increased clinical experience will ensure that complete monitoring takes place in the future. In conclusion, this project has shown that adverse effects from LTOC are prevalent in a single general practice population. It is also shown that monitoring for LTOC adverse effects is inadequate but can be improved relatively easily as skills and competencies from other medication monitoring systems already exist within healthcare settings and are immediately transferable.

  5. Neuromonitoring after major neurosurgical procedures.

    PubMed

    Messerer, M; Daniel, R T; Oddo, M

    2012-07-01

    Postoperative care of major neurosurgical procedures is aimed at the prevention, detection and treatment of secondary brain injury. This consists of a series of pathological events (i.e. brain edema and intracranial hypertension, cerebral hypoxia/ischemia, brain energy dysfunction, non-convulsive seizures) that occur early after the initial insult and surgical intervention and may add further burden to primary brain injury and thus impact functional recovery. Management of secondary brain injury requires specialized neuroscience intensive care units (ICU) and continuous advanced monitoring of brain physiology. Monitoring of intracranial pressure (ICP) is a mainstay of care and is recommended by international guidelines. However, ICP monitoring alone may be insufficient to detect all episodes of secondary brain insults. Additional invasive (i.e. brain tissue PO2, cerebral microdialysis, regional cerebral blood flow) and non-invasive (i.e. transcranial doppler, near-infrared spectroscopy, EEG) brain monitoring devices might complement ICP monitoring and help clinicians to target therapeutic interventions (e.g. management of cerebral perfusion pressure, blood transfusion, glucose control) to patient-specific pathophysiology. Several independent studies demonstrate such multimodal approach may optimize patient care after major neurosurgical procedures. The aim of this review is to evaluate some of the available monitoring systems and summarize recent important data showing the clinical utility of multimodal neuromonitoring for the management of main acute neurosurgical conditions, including traumatic brain injury, subarachnoid hemorrhage and stroke.

  6. Subsidence monitoring network: an Italian example aimed at a sustainable hydrocarbon E&P activity

    NASA Astrophysics Data System (ADS)

    Dacome, M. C.; Miandro, R.; Vettorel, M.; Roncari, G.

    2015-11-01

    According to the Italian law in order to start-up any new hydrocarbon exploitation activity, an Environmental Impact Assessment study has to be presented, including a monitoring plan, addressed to foresee, measure and analyze in real time any possible impact of the project on the coastal areas and on those ones in the close inland located. The occurrence of subsidence, that could partly be related to hydrocarbon production, both on-shore and off-shore, can generate great concern in those areas where its occurrence may have impacts on the local environment. ENI, following the international scientific community recommendations on the matter, since the beginning of 90's years, implemented a cutting-edge monitoring network, with the aim to prevent, mitigate and control geodynamics phenomena generated in the activity areas, with a particular attention to conservation and protection of environmental and territorial equilibrium, taking care of what is known as "sustainable development". The current ENI implemented monitoring surveys can be divided as: - Shallow monitoring: spirit levelling surveys, continuous GPS surveys in permanent stations, SAR surveys, assestimeter subsurface compaction monitoring, ground water level monitoring, LiDAR surveys, bathymetrical surveys. - Deep monitoring: reservoir deep compaction trough radioactive markers, reservoir static (bottom hole) pressure monitoring. All the information, gathered through the monitoring network, allow: 1. to verify if the produced subsidence is evolving accordingly with the simulated forecast. 2. to provide data to revise and adjust the prediction compaction models 3. to put in place the remedial actions if the impact exceeds the threshold magnitude originally agreed among the involved parties. ENI monitoring plan to measure and monitor the subsidence process, during field production and also after the field closure, is therefore intended to support a sustainable field development and an acceptable exploitation programme in which the actual risk connected with the field production is evaluated in advance, shared and agreed among all the involved subjects: oil company, stakeholders and local community (with interests in the affected area).

  7. Challenges in atmospheric monitoring of areal emission sources - an Open-path Fourier transform infrared (OP-FTIR) spectroscopic experience report

    NASA Astrophysics Data System (ADS)

    Schuetze, C.; Sauer, U.; Dietrich, P.

    2015-12-01

    Reliable detection and assessment of near-surface CO2 emissions from natural or anthropogenic sources require the application of various monitoring tools at different spatial scales. Especially, optical remote sensing tools for atmospheric monitoring have the potential to measure integrally CO2 emissions over larger scales (> 10.000m2). Within the framework of the MONACO project ("Monitoring approach for geological CO2 storage sites using a hierarchical observation concept"), an integrative hierarchical monitoring concept was developed and validated at different field sites with the aim to establish a modular observation strategy including investigations in the shallow subsurface, at ground surface level and the lower atmospheric boundary layer. The main aims of the atmospheric monitoring using optical remote sensing were the observation of the gas dispersion in to the near-surface atmosphere, the determination of maximum concentration values and identification of the main challenges associated with the monitoring of extended emission sources with the proposed methodological set up under typical environmental conditions. The presentation will give an overview about several case studies using the integrative approach of Open-Path Fourier Transform Infrared spectroscopy (OP FTIR) in combination with in situ measurements. As a main result, the method was validated as possible approach for continuous monitoring of the atmospheric composition, in terms of integral determination of GHG concentrations and to identify target areas which are needed to be investigated more in detail. Especially the data interpretation should closely consider the micrometeorological conditions. Technical aspects concerning robust equipment, experimental set up and fast data processing algorithms have to be taken into account for the enhanced automation of atmospheric monitoring.

  8. The association of parental monitoring and family structure with diverse maladjustment outcomes in middle adolescent boys and girls.

    PubMed

    Fröjd, Sari; Kaltiala-Heino, Riittakerttu; Rimpelä, Matti

    2007-01-01

    The aim of this study was to study the associations between family structure, parental monitoring and maladjustment outcomes among middle adolescent girls and boys. Data was collected through a school-based survey of a nationally representative sample of 17,643 Finnish adolescents aged 14-16 years. The less the parents knew the adolescents' friends and whereabouts, the more common were all the maladjustment outcomes studied. Non-intact family structure was associated with maladjustment and had associations independent of parental monitoring. We conclude that parental involvement with adolescents is conducive to healthy development, and that adolescents need the protection provided by parental supervision. Knowing the adolescent's whereabouts and friends is a concrete and easily measurable way of assessing parents' involvement in the adolescent's life.

  9. A Baseline Air Quality Assessment Onboard a Victoria Class Submarine: HMCS Windsor

    DTIC Science & Technology

    2006-05-01

    with the use of the Carbon Dioxide Absorption Units (CDAUs) in which two canisters were initiated in both the Fore Ends (foreword of Bulkhead 34 in...monitoring equipment used onboard was also checked as a confirmation. Carbon Monoxide is produced as a result of combustion, therefore the source of...aim the study monitored the effects of: air purification capabilities (management of Oxygen (O2) and Carbon Dioxide (CO2)); routine housekeeping

  10. Smartphone-Based Monitoring of Objective and Subjective Data in Affective Disorders: Where Are We and Where Are We Going? Systematic Review

    PubMed Central

    Dogan, Ezgi; Wagner, Xenija; Hegerl, Ulrich; Kohls, Elisabeth

    2017-01-01

    Background Electronic mental health interventions for mood disorders have increased rapidly over the past decade, most recently in the form of various systems and apps that are delivered via smartphones. Objective We aim to provide an overview of studies on smartphone-based systems that combine subjective ratings with objectively measured data for longitudinal monitoring of patients with affective disorders. Specifically, we aim to examine current knowledge on: (1) the feasibility of, and adherence to, such systems; (2) the association of monitored data with mood status; and (3) the effects of monitoring on clinical outcomes. Methods We systematically searched PubMed, Web of Science, PsycINFO, and the Cochrane Central Register of Controlled Trials for relevant articles published in the last ten years (2007-2017) by applying Boolean search operators with an iterative combination of search terms, which was conducted in February 2017. Additional articles were identified via pearling, author correspondence, selected reference lists, and trial protocols. Results A total of 3463 unique records were identified. Twenty-nine studies met the inclusion criteria and were included in the review. The majority of articles represented feasibility studies (n=27); two articles reported results from one randomized controlled trial (RCT). In total, six different self-monitoring systems for affective disorders that used subjective mood ratings and objective measurements were included. These objective parameters included physiological data (heart rate variability), behavioral data (phone usage, physical activity, voice features), and context/environmental information (light exposure and location). The included articles contained results regarding feasibility of such systems in affective disorders, showed reasonable accuracy in predicting mood status and mood fluctuations based on the objectively monitored data, and reported observations about the impact of monitoring on clinical state and adherence of patients to the system usage. Conclusions The included observational studies and RCT substantiate the value of smartphone-based approaches for gathering long-term objective data (aside from self-ratings to monitor clinical symptoms) to predict changes in clinical states, and to investigate causal inferences about state changes in patients with affective disorders. Although promising, a much larger evidence-base is necessary to fully assess the potential and the risks of these approaches. Methodological limitations of the available studies (eg, small sample sizes, variations in the number of observations or monitoring duration, lack of RCT, and heterogeneity of methods) restrict the interpretability of the results. However, a number of study protocols stated ambitions to expand and intensify research in this emerging and promising field. PMID:28739561

  11. Arduino Based Infant Monitoring System

    NASA Astrophysics Data System (ADS)

    Farhanah Mohamad Ishak, Daing Noor; Jamil, Muhammad Mahadi Abdul; Ambar, Radzi

    2017-08-01

    This paper proposes a system for monitoring infant in an incubator and records the relevant data into a computer. The data recorded by the system can be further referred by the neonatal intensive care unit (NICU) personnel for diagnostic or research purposes. The study focuses on designing the monitoring system that consists of an incubator equipped with humidity sensor to measure the humidity level, and a pulse sensor that can be attached on an infant placed inside the incubator to monitor infant’s heart pulse. The measurement results which are the pulse rate and humidity level are sent to the PC via Arduino microcontroller. The advantage of this system will be that in the future, it may also enable doctors to closely monitor the infant condition through local area network and internet. This work is aimed as an example of an application that contributes towards remote tele-health monitoring system.

  12. [The lesions of flat epithelial atypia diagnosed on breast biopsy].

    PubMed

    Peres, A; Becette, V; Guinebretiere, J-M; Cherel, P; Barranger, E

    2011-10-01

    Among pre-invasive breast diseases, the lesion of flat epithelial atypia has a level of risk that remains unclear. The clinical significance of these lesions and how to behave during their diagnostic biopsy (monitoring vs. surgery) are still uncertain, because few studies (including monitoring) are available and because of the polymorphic spectrum of lesions and their many denominations across the studies in the literature. This article aims to update our knowledge and provide elements for the management of these lesions diagnosed on breast biopsy. Copyright © 2011. Published by Elsevier SAS.

  13. Blood pressure self-monitoring in pregnancy: examining feasibility in a prospective cohort study.

    PubMed

    Tucker, Katherine L; Taylor, Kathryn S; Crawford, Carole; Hodgkinson, James A; Bankhead, Clare; Carver, Tricia; Ewers, Elizabeth; Glogowska, Margaret; Greenfield, Sheila M; Ingram, Lucy; Hinton, Lisa; Khan, Khalid S; Locock, Louise; Mackillop, Lucy; McCourt, Christine; Pirie, Alexander M; Stevens, Richard; McManus, Richard J

    2017-12-28

    Raised blood pressure (BP) affects approximately 10% of pregnancies worldwide, and a high proportion of affected women develop pre-eclampsia. This study aimed to evaluate the feasibility of self-monitoring of BP in pregnancy in women at higher risk of pre-eclampsia. This prospective cohort study of self-monitoring BP in pregnancy was carried out in two hospital trusts in Birmingham and Oxford and thirteen primary care practices in Oxfordshire. Eligible women were those defined by the UK National Institute for Health and Care Excellence (NICE) guidelines as at higher risk of pre-eclampsia. A total of 201 participants were recruited between 12 and 16 weeks of pregnancy and were asked to take two BP readings twice daily three times a week through their pregnancy. Primary outcomes were recruitment, retention and persistence of self-monitoring. Study recruitment and retention were analysed with descriptive statistics. Survival analysis was used to evaluate the persistence of self-monitoring and the performance of self-monitoring in the early detection of gestational hypertension, compared to clinic BP monitoring. Secondary outcomes were the mean clinic and self-monitored BP readings and the performance of self-monitoring in the detection of gestational hypertension and pre-eclampsia compared to clinic BP. Of 201 women recruited, 161 (80%) remained in the study at 36 weeks or to the end of their pregnancy, 162 (81%) provided any home readings suitable for analysis, 148 (74%) continued to self-monitor at 20 weeks and 107 (66%) at 36 weeks. Self-monitored readings were similar in value to contemporaneous matched clinic readings for both systolic and diastolic BP. Of the 23 who developed gestational hypertension or pre-eclampsia and self-monitored, 9 (39%) had a raised home BP prior to a raised clinic BP. Self-monitoring of BP in pregnancy is feasible and has potential to be useful in the early detection of gestational hypertensive disorders but maintaining self-monitoring throughout pregnancy requires support and probably enhanced training.

  14. Recommendations for standards of monitoring during anaesthesia and recovery 2015: Association of Anaesthetists of Great Britain and Ireland.

    PubMed

    Checketts, M R; Alladi, R; Ferguson, K; Gemmell, L; Handy, J M; Klein, A A; Love, N J; Misra, U; Morris, C; Nathanson, M H; Rodney, G E; Verma, R; Pandit, J J

    2016-01-01

    This guideline updates and replaces the 4th edition of the AAGBI Standards of Monitoring published in 2007. The aim of this document is to provide guidance on the minimum standards for physiological monitoring of any patient undergoing anaesthesia or sedation under the care of an anaesthetist. The recommendations are primarily aimed at anaesthetists practising in the United Kingdom and Ireland. Minimum standards for monitoring patients during anaesthesia and in the recovery phase are included. There is also guidance on monitoring patients undergoing sedation and also during transfer of anaesthetised or sedated patients. There are new sections discussing the role of monitoring depth of anaesthesia, neuromuscular blockade and cardiac output. The indications for end-tidal carbon dioxide monitoring have been updated. © 2015 The Authors. Anaesthesia published by John Wiley & Sons Ltd on behalf of Association of Anaesthetists of Great Britain and Ireland.

  15. The vertical monitor position for presbyopic computer users with progressive lenses: how to reach clear vision and comfortable head posture.

    PubMed

    Weidling, Patrick; Jaschinski, Wolfgang

    2015-01-01

    When presbyopic employees are wearing general-purpose progressive lenses, they have clear vision only with a lower gaze inclination to the computer monitor, given the head assumes a comfortable inclination. Therefore, in the present intervention field study the monitor position was lowered, also with the aim to reduce musculoskeletal symptoms. A comparison group comprised users of lenses that do not restrict the field of clear vision. The lower monitor positions led the participants to lower their head inclination, which was linearly associated with a significant reduction in musculoskeletal symptoms. However, for progressive lenses a lower head inclination means a lower zone of clear vision, so that clear vision of the complete monitor was not achieved, rather the monitor should have been placed even lower. The procedures of this study may be useful for optimising the individual monitor position depending on the comfortable head and gaze inclination and the vertical zone of clear vision of progressive lenses. For users of general-purpose progressive lenses, it is suggested that low monitor positions allow for clear vision at the monitor and for a physiologically favourable head inclination. Employees may improve their workplace using a flyer providing ergonomic-optometric information.

  16. Remote Autonomous Sensor Networks: A Study in Redundancy and Life Cycle Costs

    NASA Astrophysics Data System (ADS)

    Ahlrichs, M.; Dotson, A.; Cenek, M.

    2017-12-01

    The remote nature of the United States and Canada border and their extreme seasonal shifts has made monitoring much of the area impossible using conventional monitoring techniques. Currently, the United States has large gaps in its ability to detect movement on an as-needed-basis in remote areas. The proposed autonomous sensor network aims to meet that need by developing a product that is low cost, robust, and can be deployed on an as-needed-basis for short term monitoring events. This is accomplished by identifying radio frequency disturbance and acoustic disturbance. This project aims to validate the proposed design and offer optimization strategies by conducting a redundancy model as well as performing a Life Cycle Assessment (LCA). The model will incorporate topological, meteorological, and land cover datasets to estimate sensor loss over a three-month period, ensuring that the remaining network does not have significant gaps in coverage which preclude being able to receive and transmit data. The LCA will investigate the materials used to create the sensor to generate an estimate of the total environmental energy that is utilized to create the network and offer alternative materials and distribution methods that can lower this cost. This platform can function as a stand-alone monitoring network or provide additional spatial and temporal resolution to existing monitoring networks. This study aims to create the framework to determine if a sensor's design and distribution is appropriate for the target environment. The incorporation of a LCA will seek to answer if the data a proposed sensor network will collect outweighs the environmental damage that will result from its deployment. Furthermore, as the arctic continues to thaw and economic development grows, the methodology described in paper will function as a guidance document to ensure that future sensor networks have a minimal impact on these pristine areas.

  17. Risk assessment of occupational exposure to heavy metal mixtures: a study protocol.

    PubMed

    Omrane, Fatma; Gargouri, Imed; Khadhraoui, Moncef; Elleuch, Boubaker; Zmirou-Navier, Denis

    2018-03-05

    Sfax is a very industrialized city located in the southern region of Tunisia where heavy metals (HMs) pollution is now an established matter of fact. The health of its residents mainly those engaged in industrial metals-based activities is under threat. Indeed, such workers are being exposed to a variety of HMs mixtures, and this exposure has cumulative properties. Whereas current HMs exposure assessment is mainly carried out using direct air monitoring approaches, the present study aims to assess health risks associated with chronic occupational exposure to HMs in industry, using a modeling approach that will be validated later on. To this end, two questionnaires were used. The first was an identification/descriptive questionnaire aimed at identifying, for each company: the specific activities, materials used, manufactured products and number of employees exposed. The second related to the job-task of the exposed persons, workplace characteristics (dimensions, ventilation, etc.), type of metals and emission configuration in space and time. Indoor air HMs concentrations were predicted, based on the mathematical models generally used to estimate occupational exposure to volatile substances (such as solvents). Later on, and in order to validate the adopted model, air monitoring will be carried out, as well as some biological monitoring aimed at assessing HMs excretion in the urine of workers volunteering to participate. Lastly, an interaction-based hazard index HI int and a decision support tool will be used to predict the cumulative risk assessment for HMs mixtures. One hundred sixty-one persons working in the 5 participating companies have been identified. Of these, 110 are directly engaged with HMs in the course of the manufacturing process. This model-based prediction of occupational exposure represents an alternative tool that is both time-saving and cost-effective in comparison with direct air monitoring approaches. Following validation of the different models according to job processes, via comparison with direct measurements and exploration of correlations with biological monitoring, these estimates will allow a cumulative risk characterization.

  18. EXPOSURE TO VOLATILE ORGANIC COMPOUNDS MEASURED IN A SOURCE IMPACTED AIRSHED

    EPA Science Inventory

    A three-year exposure monitoring study is being conducted in a large city in the Midwestern U.S. The study is aimed at determining the factors influencing exposures to air pollutants of outdoor origin, including volatile organic compounds (VOCs) and particulate matter.

  19. Moderator Role of Monitoring in the Inhibitory Control of Adolescents With ADHD.

    PubMed

    Ramos-Galarza, Carlos; Pérez-Salas, Claudia

    2018-05-01

    The aim of this research was to analyze the role of monitoring in the causal relationship between inhibitory control and symptoms of combined ADHD. It has been conducted a quantitative investigation of two phases. In the first study, a moderation model was analyzed ( N = 144 adolescents with combined ADHD), where monitoring was considered as a moderating variable in the causal relationship between the inhibitory control and the symptomatology of ADHD F(3, 140) = 28.03, p < .001; R 2 = .37. In the second study, the model through an experimental study was tested ( N = 52 adolescents with and without ADHD) where it was found that adolescents with ADHD improve in their inhibitory control when they receive external support to the monitoring F(1, 50) = 21.38, p < .001, η 2 = .30. Results suggest that monitoring compensates the poor performance of inhibitory control in adolescents with ADHD, which is a contribution to the theoretical construction of ADHD and to the treatments proposed for this condition because it goes beyond the classic conception of a causality chain among the deficit of inhibitory control and ADHD symptomatology to propose a new explanation about this disorder, where neuropsychology intervention of monitoring would diminish ADHD's symptomatology impact on adolescents.

  20. Formal verification of medical monitoring software using Z language: a representative sample.

    PubMed

    Babamir, Seyed Morteza; Borhani, Mehdi

    2012-08-01

    Medical monitoring systems are useful aids assisting physicians in keeping patients under constant surveillance; however, taking sound decision by the systems is a physician concern. As a result, verification of the systems behavior in monitoring patients is a matter of significant. The patient monitoring is undertaken by software in modern medical systems; so, software verification of modern medial systems have been noticed. Such verification can be achieved by the Formal Languages having mathematical foundations. Among others, the Z language is a suitable formal language has been used to formal verification of systems. This study aims to present a constructive method to verify a representative sample of a medical system by which the system is visually specified and formally verified against patient constraints stated in Z Language. Exploiting our past experience in formal modeling Continuous Infusion Insulin Pump (CIIP), we think of the CIIP system as a representative sample of medical systems in proposing our present study. The system is responsible for monitoring diabetic's blood sugar.

  1. Predicting Students Drop Out: A Case Study

    ERIC Educational Resources Information Center

    Dekker, Gerben W.; Pechenizkiy, Mykola; Vleeshouwers, Jan M.

    2009-01-01

    The monitoring and support of university freshmen is considered very important at many educational institutions. In this paper we describe the results of the educational data mining case study aimed at predicting the Electrical Engineering (EE) students drop out after the first semester of their studies or even before they enter the study program…

  2. [Intracranial pressure monitoring and CSF dynamics in patients with neurological disorders: indications and practical considerations].

    PubMed

    Poca, M; Sahuquillo, J

    2001-01-01

    The study of cerebrospinal fluid (CSF) dynamics is central to the diagnosis of adult chronic hydrocephalus (ACH). At present, many neurology and neurosurgery departments use one or more tests to guide diagnosis of this syndrome and to predict patient response to shunting. In specialised centres, the study of CSF dynamics is combined with continuous intracranial pressure (ICP) monitoring. Determination of several variables of CSF dynamics and definitions of qualitative and quantitative characteristics of ICP can be used to establish whether the hydrocephalus is active, compensated or arrested. CSF dynamics and ICP monitoring can also be used to check the correct functioning of the shunt and can be of use in the clinical management of patients with pseudotumor cerebri. Moreover, ICP monitoring is used to guide the treatment of several acute neurological processes. The aim of this review is to describe the fundamentals of CSF dynamics studies and the bases of continuous ICP monitoring. The advantages and disadvantages of several hydrodynamic tests that can be performed by lumbar puncture, as well as the normal and abnormal characteristics of an ICP recording, are discussed.

  3. Assessment of TRMM 3B43 product for drought monitoring in Singapore

    NASA Astrophysics Data System (ADS)

    Tan, Mou Leong; Chua, Vivien P.; Tan, Kok Chooi; Brindha, K.

    2017-10-01

    Drought is one of the most hazardous natural disasters for human beings and the environment. Using only rain gauge is insufficient to monitor the drought pattern effectively as it impacts large areas. This situation is more critical on small island countries, with limited rain gauges for monitoring drought pattern over the ocean regions. This study aims to assess the capability of Tropical Rainfall Measuring Mission (TRMM) Multisatellite Precipitation Analysis (TMPA) 3B43 product in monitoring drought in Singapore from 1998 to 2014. The Standardized Precipitation Index (SPI) at various time-scales is used for identifying drought patterns. Results show moderate to good correlations between TMPA- 3B43 and rain gauges in the SPI estimations. Besides that, TMPA-3B43 exhibits a similar temporal drought behavior as the rain gauges. These findings indicate the TMPA 3B43 product as a very useful tool to study drought pattern over Singapore.

  4. Remote health monitoring using mobile phones and Web services.

    PubMed

    Agarwal, Sparsh; Lau, Chiew Tong

    2010-06-01

    Diabetes and hypertension have become very common perhaps because of increasingly busy lifestyles, unhealthy eating habits, and a highly competitive workplace. The rapid advancement of mobile communication technologies offers innumerable opportunities for the development of software and hardware applications for remote monitoring of such chronic diseases. This study describes a remote health-monitoring service that provides an end-to-end solution, that is, (1) it collects blood pressure readings from the patient through a mobile phone; (2) it provides these data to doctors through a Web interface; and (3) it enables doctors to manage the chronic condition by providing feedback to the patients remotely. This article also aims at understanding the requirements and expectations of doctors and hospitals from such a remote health-monitoring service.

  5. Characterization of optically stimulated luminescence dosimeters and investigating their potential for estimating pediatric organ doses in multi-slice computed tomography

    NASA Astrophysics Data System (ADS)

    Al-Senan, Rani Mohammed

    Recent epidemiologic studies have shown a strong association between the relatively high doses of pediatric CT and the risk of cancer. Quantifying organ doses, as a measure of the risk, is commonly based on either direct anthropomorphic phantom measurements or Monte Carlo simulation. The major disadvantage in the phantom approach is its high cost especially that, for pediatric CT dosimetry, various phantom sizes are required to represent different age groups of children. On the other hand, Monte Carlo simulation, although not considered costly, requires validation by anthropomorphic phantom measurements. The aim of this project was to develop two methods of organ dose estimation in pediatric CT: 1) from the measured surface dose using optically stimulated luminescence dosimeters (OSLDs) and 2) by measuring the circumference of the body part being scanned as well as knowing the scan parameters. The project was based on a study proposed by the surgery department to monitor radiation exposure to children during their CT examination in the ER. A total of 200 pediatric patients were enrolled in this study which used OSLDs to monitor the doses. Specific aim 1 of this project was to characterize the OSLDs in the diagnostic energy range. Specific aim 2(a) was to find relationships between the patients' doses from OSLDs and both scan CTDI and the measured circumference. In specific aim 2(b) we carried out measurements using CTDI phantoms to investigate the relationships studied in specific aim 2(a). Specific aim 3 was to come up with models to estimate select organ doses from measuring surface dose or by using the circumference of the body part. To do this, pediatric examinations were simulated using a set of pediatric anthropomorphic phantoms in which doses of select organs were measured.

  6. Using a portable sulfide monitor as a motivational tool: a clinical study.

    PubMed

    Uppal, Ranjit Singh; Malhotra, Ranjan; Grover, Vishakha; Grover, Deepak

    2012-01-01

    Bad breath has a significant impact on daily life of those who suffer from it. Oral malodor may rank only behind dental caries and periodontal disease as the cause of patient's visit to dentist. An aim of this study was to use a portable sulfide monitor as a motivational tool for encouraging the patients towards the better oral hygiene by correlating the plaque scores with sulfide monitor scores, and comparing the sulfide monitor scores before and after complete prophylaxis and 3 months after patient motivation. 30 patients with chronic periodontitis, having chief complaint of oral malodor participated in this study. At first visit, the plaque scores (P1) and sulfide monitor scores before (BCR1) and after complete oral prophylaxis (BCR2) were taken. Then the patients were motivated towards the better oral hygiene. After 3 months, plaque scores (P2) and sulfide monitor scores (BCR3) were recorded again. It was done using SPSS (student package software for statistical analysis). Paired sample test was performed. Statistically significant reduction in sulfide monitor scores was reported after the complete oral prophylaxis and 3 months after patient motivation. Plaque scores were significantly reduced after a period of 3 months. Plaque scores and breathchecker scores were positively correlated. An intensity of the oral malodor was positively correlated with the plaque scores. The portable sulfide monitor was efficacious in motivating the patients towards the better oral hygiene.

  7. Bridge Displacement Monitoring Method Based on Laser Projection-Sensing Technology

    PubMed Central

    Zhao, Xuefeng; Liu, Hao; Yu, Yan; Xu, Xiaodong; Hu, Weitong; Li, Mingchu; Ou, Jingping

    2015-01-01

    Bridge displacement is the most basic evaluation index of the health status of a bridge structure. The existing measurement methods for bridge displacement basically fail to realize long-term and real-time dynamic monitoring of bridge structures, because of the low degree of automation and the insufficient precision, causing bottlenecks and restriction. To solve this problem, we proposed a bridge displacement monitoring system based on laser projection-sensing technology. First, the laser spot recognition method was studied. Second, the software for the displacement monitoring system was developed. Finally, a series of experiments using this system were conducted, and the results show that such a system has high measurement accuracy and speed. We aim to develop a low-cost, high-accuracy and long-term monitoring method for bridge displacement based on these preliminary efforts. PMID:25871716

  8. Blast optimization for improved dragline productivity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Humphreys, M.; Baldwin, G.

    1994-12-31

    A project aimed at blast optimization for large open pit coal mines is utilizing blast monitoring and analysis techniques, advanced dragline monitoring equipment, and blast simulation software, to assess the major controlling factors affecting both blast performance and subsequent dragline productivity. This has involved collaborative work between the explosives supplier, mine operator, monitoring equipment manufacturer, and a mining research organization. The results from trial blasts and subsequently monitored dragline production have yielded promising results and continuing studies are being conducted as part of a blast optimization program. It should be stressed that the optimization of blasting practices for improved draglinemore » productivity is a site specific task, achieved through controlled and closely monitored procedures. The benefits achieved at one location can not be simply transferred to another minesite unless similar improvement strategies are first implemented.« less

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zenoni, Aldo; INFN Sezione di Pavia, Via Bassi 6, 27100 Pavia,

    Cosmic ray radiation is mostly composed, at sea level, by high energy muons, which are highly penetrating particles capable of crossing kilometers of rock. The ubiquitous and steady presence at the Earth's surface and the high penetration capability have motivated the use of cosmic ray radiation also in fields beyond particle physics, from geology, archaeology, speleology to industrial applications and homeland security. In particular, in recent years, the novel technique of muon tomography has been proposed, with the aim of performing non invasive inspection of large non accessible volumes, material atomic number Z and density discrimination, and three dimension imagemore » reconstruction of the inspected volume. In the present paper, after a short recall of the physical principles and mathematical formalism on which muon tomography is based, a number of examples of application of the novel technique in industry and homeland security issues is given. Moreover, a new application of cosmic rays detection techniques in the field of civil engineering is proposed. The aim is the monitoring of the stability of large structures, in particular the static monitoring of historical buildings, where conservation constraints are more severe and the time evolution of the deformation phenomena under study may be of the order of months or years. The new technique may be seen, in some way, as the reverse problem of muon tomography. As a significant case study, the monitoring of the wooden vaulted roof of the Palazzo della Loggia in the town of Brescia, in Italy, has been considered. The feasibility as well as the performances and limitations of a monitoring system based on cosmic ray tracking have been studied by Monte Carlo simulation and discussed in comparison with more traditional monitoring systems. (authors)« less

  10. The feasibility and RE-AIM evaluation of the TAME health pilot study.

    PubMed

    Lewis, Zakkoyya H; Ottenbacher, Kenneth J; Fisher, Steve R; Jennings, Kristofer; Brown, Arleen F; Swartz, Maria C; Martinez, Eloisa; Lyons, Elizabeth J

    2017-08-14

    Conducting 5 A's counseling in clinic and utilizing technology-based resources are recommended to promote physical activity but little is known about how to implement such an intervention. This investigation aimed to determine the feasibility and acceptability, using the RE-AIM (Reach, Effectiveness, Adoption, Implementation, Maintenance) framework, of a pragmatic, primary care-based intervention that incorporated 5 A's counseling and self-control through an activity monitor. Primary care patients (n = 40) 55-74 years of age were recruited and randomized to receive a pedometer or an electronic activity monitor (EAM), Jawbone UP24, to monitor activity for 12 weeks. Participants were also invited to a focus group after completing the intervention. Stakeholders (n = 36) were recruited to provide feedback. The intervention recruitment rate was 24.7%. The attrition rate was 20% with a significantly higher rate for the pedometer group (p = 0.02). The EAM group increased their minutes of physical activity by 11.1 min/day while the pedometer maintained their activity (0.2 min/day), with no significant group difference. EAM participants liked using their monitor and would continue wearing it while the pedometer group was neutral to these statements (p < 0.05). Over the 12 weeks there were 490 comments and 1094 "likes" given to study peers in the corresponding application for the UP24 monitor. Some EAM participants enjoyed the social interaction feature while others were uncomfortable talking to strangers. Participants stated they would want counseling from a counselor and not their physician or a nurse. Other notable comments included incorporating multiple health behaviors, more in-person counseling with a counselor, and having a funding source for sustainability. Overall, the study was well-received but the results raise a number of considerations. Practitioners, counselors, and researchers should consider the following before implementing a similar intervention: 1) utilize PA counselors, 2) target multiple health behaviors, 3) form a social support group, 4) identify a funding source for sustainability, and 5) be mindful of concerns with technology. clinicaltrials.gov- NCT02554435 . Registered 24 August 2015.

  11. Comparing two motor assessment tools to evaluate neurobehavioral intervention effects in infants with very low birth weight at 1 year.

    PubMed

    Van Hus, Janeline W P; Jeukens-Visser, Martine; Koldewijn, Karen; Van Sonderen, Loekie; Kok, Joke H; Nollet, Frans; Van Wassenaer-Leemhuis, Aleid G

    2013-11-01

    Infants with very low birth weight (VLBW) are at increased risk for motor deficits, which may be reduced by early intervention programs. For detection of motor deficits and to monitor intervention, different assessment tools are available. It is important to choose tools that are sensitive to evaluate the efficacy of intervention on motor outcome. The purpose of this study was to compare the Alberta Infant Motor Scale (AIMS) and the Psychomotor Developmental Index (PDI) of the Bayley Scales of Infant Development-Dutch Second Edition (BSID-II-NL) in their ability to evaluate effects of an early intervention, provided by pediatric physical therapists, on motor development in infants with VLBW at 12 months corrected age (CA). This was a secondary study in which data collected from a randomized controlled trial (RCT) were used. At 12 months CA, 116 of 176 infants with VLBW participating in an RCT on the effect of the Infant Behavioral Assessment and Intervention Program were assessed with both the AIMS and the PDI. Intervention effects on the AIMS and PDI were compared. Corrected for baseline differences, significant intervention effects were found for AIMS and PDI scores. The highest effect size was for the AIMS subscale sit. A significant reduction of abnormal motor development in the intervention group was found only with the AIMS. No Dutch norms are available for the AIMS. The responsiveness of the AIMS to detect intervention effects was better than that of the PDI. Therefore, caution is recommended in monitoring infants with VLBW only with the PDI, and the use of both the AIMS and the Bayley Scales of Infant Development is advised when evaluating intervention effects on motor development at 12 months CA.

  12. Motor development of preterm infants assessed by the Alberta Infant Motor Scale: systematic review article.

    PubMed

    Fuentefria, Rubia do N; Silveira, Rita C; Procianoy, Renato S

    Premature newborns are considered at risk for motor development deficits, leading to the need for monitoring in early life. The aim of this study was to systematically review the literature about gross motor development of preterm infants, assessed by the Alberta Infant Motor Scale (AIMS) to identify the main outcomes in development. Systematic review of studies published from 2006 to 2015, indexed in Pubmed, Scielo, Lilacs, and Medline databases in English and Portuguese. The search strategy included the keywords: Alberta Infant Motor Scale, prematurity, preterm, motor development, postural control, and follow-up. A total of 101 articles were identified and 23 were selected, according to the inclusion criteria. The ages of the children assessed in the studies varied, including the first 6 months up to 15 or 18 months of corrected age. The percentage variation in motor delay was identified in the motor outcome descriptions of ten studies, ranging from 4% to 53%, depending on the age when the infant was assessed. The studies show significant differences in the motor development of preterm and full-term infants, with a description of lower gross scores in the AIMS results of preterm infants. It is essential that the follow-up services of at-risk infants have assessment strategies and monitoring of gross motor development of preterm infants; AIMS is an assessment tool indicated to identify atypical motor development in this population. Copyright © 2017. Published by Elsevier Editora Ltda.

  13. Is Technology-Mediated Parental Monitoring Related to Adolescent Substance Use?

    PubMed

    Rudi, Jessie; Dworkin, Jodi

    2018-01-03

    Prevention researchers have identified parental monitoring leading to parental knowledge to be a protective factor against adolescent substance use. In today's digital society, parental monitoring can occur using technology-mediated communication methods, such as text messaging, email, and social networking sites. The current study aimed to identify patterns, or clusters, of in-person and technology-mediated monitoring behaviors, and examine differences between the patterns (clusters) in adolescent substance use. Cross-sectional survey data were collected from 289 parents of adolescents using Facebook and Amazon Mechanical Turk (MTurk). Cluster analyses were computed to identify patterns of in-person and technology-mediated monitoring behaviors, and chi-square analyses were computed to examine differences in substance use between the identified clusters. Three monitoring clusters were identified: a moderate in-person and moderate technology-mediated monitoring cluster (moderate-moderate), a high in-person and high technology-mediated monitoring cluster (high-high), and a high in-person and low technology-mediated monitoring cluster (high-low). Higher frequency of technology-mediated parental monitoring was not associated with lower levels of substance use. Results show that higher levels of technology-mediated parental monitoring may not be associated with adolescent substance use.

  14. Design of a Forecasting Service System for Monitoring of Vulnerabilities of Sensor Networks

    NASA Astrophysics Data System (ADS)

    Song, Jae-Gu; Kim, Jong Hyun; Seo, Dong Il; Kim, Seoksoo

    This study aims to reduce security vulnerabilities of sensor networks which transmit data in an open environment by developing a forecasting service system. The system is to remove or monitor causes of breach incidents in advance. To that end, this research first examines general security vulnerabilities of sensor networks and analyzes characteristics of existing forecasting systems. Then, 5 steps of a forecasting service system are proposed in order to improve security responses.

  15. Multiscale ecosystem monitoring: an application of scaling data to answer multiple ecological questions

    USDA-ARS?s Scientific Manuscript database

    Standardized monitoring data collection efforts using a probabilistic sample design, such as in the Bureau of Land Management’s (BLM) Assessment, Inventory, and Monitoring (AIM) Strategy, provide a core suite of ecological indicators, maximize data collection efficiency, and promote reuse of monitor...

  16. The Spanish version of the Alberta Infant Motor Scale: Validity and reliability analysis.

    PubMed

    Morales-Monforte, Erica; Bagur-Calafat, Caridad; Suc-Lerin, Neus; Fornaguera-Martí, Montserrat; Cazorla-Sánchez, Engracia; Girabent-Farrés, Montserrat

    2017-02-01

    Validity and reliability of the cross-cultural adaptive translation of the Alberta Infant Motor Scale (AIMS), to monitor gross motor development in infants from 0 to 18 months of age, were evaluated. A cross-cultural translation was used to generate a Spanish version of the AIMS. Fifty infants at risk or with diagnosis of motor delay, 0-18 months of age, participated in this study. Two independent physical therapists scored infants on the AIMS. Concurrent validity was tested using the AIMS and the Bayley Scales of Infant and Toddler Development - III (Bayley - III). Reliability and the internal consistency were high (ICCs ranged from 0.94 to 1.00 and KR-20 ranged from 0.90 to 0.98, respectively). AIMS and Bayley - III scores correlated strongly (r = 0.97). The Spanish version of the AIMS presented excellent validity and reliability. Further studies are suggested in order to assess the AIMS in preterm babies.

  17. Evaluating public education messages aimed at monitoring and responding to social interactive technology on smartphones among young drivers.

    PubMed

    Gauld, Cassandra S; Lewis, Ioni; White, Katherine M; Fleiter, Judy J; Watson, Barry

    2017-07-01

    Young drivers are more likely than any other age group to access social interactive technology (e.g., Facebook, E-mail) on a smartphone while driving. The current study formed part of a larger investigation and was guided by The Step Approach to Message Design and Testing (SatMDT) to evaluate the relative effectiveness of three different public education messages aimed at reducing smartphone use among young drivers. The messages were each adapted to the specific behaviours of monitoring/reading and responding to social interactive technology on smartphones. Participants (n=288; 199F, 89M) were drivers aged 17-25 years who resided in the Australian state of Queensland. Message acceptance (i.e., intention and effectiveness) and message rejection were both assessed using a self-report survey. Multivariate analyses found that, overall, the messages targeting monitoring/reading behaviour were considered more effective than those targeting responding behaviour. The message that challenged the underlying motivation that believing you are a good driver makes it easier to monitor/read social interactive technology while driving was considered particularly effective by young male drivers. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. High quality data: An evaluation of AIM data quality and data quality procedures

    USDA-ARS?s Scientific Manuscript database

    The goal of every monitoring program is to collect high-quality data which can then be used to provide information to decision makers. The Bureau of Land Management (BLM) Assessment, Inventory, and Monitoring (AIM) program is one such data set which provides rangeland status, condition, and trend in...

  19. The American Society of Neurophysiological Monitoring position statements project.

    PubMed

    Morledge, David E; Stecker, Mark

    2006-02-01

    The American Society of Neurophysiological Monitoring (ASNM) is developing position statements aimed at assisting practitioners and others in making decisions regarding neurophysiological monitoring practice. This paper describes the procedures used in drafting these documents.

  20. Increasing Parent Involvement in Youth HIV Prevention: A Randomized Caribbean Study

    ERIC Educational Resources Information Center

    Baptiste, Donna R.; Kapungu, Chisina; Miller, Steve; Crown, Laurel; Henry, David; Da Costa Martinez, Dona; Jo-Bennett, Karen

    2009-01-01

    This article presents preliminary findings of a randomized HIV prevention study in Trinidad and Tobago in the Caribbean. The study centers on a family HIV workshop aimed at strengthening parenting skills that are empirically linked to reducing adolescent HIV exposure and other sexual risks. These skills include parental monitoring; educating youth…

  1. Study of flash floods over some parts of Brazil using precipitation index

    NASA Astrophysics Data System (ADS)

    Souza, D.; de Souza, R. L. M.; Araujo, R.

    2016-12-01

    In Brazil, the main phenomena related to natural disasters are derived from the Earth's external dynamics such as floods and flash floods, landslides and storms, where the flash flood phenomenon causes the second highest number of victims, totaling more than 32% of deaths. Floods and flash floods are natural events often triggered by storms or long period of rains, usually associated with rising volume of rainfall on the watershed, leading the river to exceed its maximum. Whereas the occurrence of natural disasters in Brazil is increasing in recent years, the use of more accurate tools to aid in the monitoring of extreme hydrological events it becomes necessary, aiming to decrease the number of human and material losses. In this context, this paper aims to implement an early warning and monitoring system related to extreme precipitation values and hydrological processes. So, initially was studied flood events in the states of São Paulo and Paraná, aimed de determination of the characteristics of rainfall and atmosphere. Later it was used an indicator of precipitation based on the climatology, which indicates warning points on the drainage network related to extreme precipitation, which are obtained by remote sensing sources, for example, radar and satellite, and numerical weather prediction data of short and very short term. The results indicated that most of the flood events over the study area was related to rainfall of deep convection. The use of precipitation indicators also helped the monitoring and the early warning, showing this to be an excellent tool for applications related to flash floods.

  2. A survey of social media data analysis for physical activity surveillance.

    PubMed

    Liu, Sam; Young, Sean D

    2018-07-01

    Social media data can provide valuable information regarding people's behaviors and health outcomes. Previous studies have shown that social media data can be extracted to monitor and predict infectious disease outbreaks. These same approaches can be applied to other fields including physical activity research and forensic science. Social media data have the potential to provide real-time monitoring and prediction of physical activity level in a given region. This tool can be valuable to public health organizations as it can overcome the time lag in the reporting of physical activity epidemiology data faced by traditional research methods (e.g. surveys, observational studies). As a result, this tool could help public health organizations better mobilize and target physical activity interventions. The first part of this paper aims to describe current approaches (e.g. topic modeling, sentiment analysis and social network analysis) that could be used to analyze social media data to provide real-time monitoring of physical activity level. The second aim of this paper was to discuss ways to apply social media analysis to other fields such as forensic sciences and provide recommendations to further social media research. Copyright © 2016 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  3. Using the best available data: integrating field data and remote sensing imagery to monitor rangelands

    USDA-ARS?s Scientific Manuscript database

    Monitoring of rangelands poses significant challenges to land managers due to broad extent and many uses of rangelands. The Bureau of Land Management’s (BLM) Assessment, Inventory, and Monitoring (AIM) program seeks to efficiently collect standard, quantitative monitoring data which is collected onc...

  4. A Statistical Study on Higher Educational Institutions in India

    ERIC Educational Resources Information Center

    Neelaveni, C.; Manimaran, S.

    2014-01-01

    This study aims to observe the increased effectiveness of Higher Educational Institutions in India and its competitiveness. It proposes to develop the interest in enhancing the quality in Educational Institutions. It is monitored and evaluated through rapid growth of information technology, which makes sophisticated data collection possible. This…

  5. INDIRECT MEASUREMENT OF BIOLOGICAL ACTIVITY TO MONITOR NATURAL ATTENUATION

    EPA Science Inventory

    The remediation of ground water contamination by natural attenuation, specifically biodegradation, requires continual monitoring. This research is aimed at improving methods for evaluating the long-term performance of Monitored Natural Attenuation (MNA), specifically changes in ...

  6. Patient satisfaction with extended-interval warfarin monitoring.

    PubMed

    Carris, Nicholas W; Hwang, Andrew Y; Smith, Steven M; Taylor, James R; Sando, Karen; Powell, Jason; Rosenberg, Eric I; Zumberg, Marc S; Gums, John G; Dietrich, Eric A; Anderson, Katherine Vogel

    2016-11-01

    Extended-interval monitoring of warfarin has been proposed to reduce follow-up burden and improve patient satisfaction. We aimed to make an initial assessment of anticoagulation satisfaction before and after an extended-interval warfarin monitoring intervention. We conducted a translational prospective single-arm pilot study of extended-interval warfarin monitoring in five pharmacist-managed anticoagulation clinics. Patients meeting CHEST guideline criteria for extended-interval warfarin monitoring began progressive extended-interval follow-up (6, 8, and 12 weeks thereafter). The Duke Anticoagulation Satisfaction Scale (DASS) was administered at baseline and at end-of-study or study removal (in patients no longer appropriate for extended interval follow-up). Forty-six patients had evaluable pre- and post-intervention DASS survey data. Mean age of patients was 66.5 years, 74 % were non-Hispanic whites, and 48 % were men. Patients completed a mean ± SD of 34 ± 22 weeks of follow-up. Mean ± SD total DASS score at baseline was 45.2 ± 14.2 versus 49.1 ± 14.9 at end-of-study (mean change, +3.9 [95 % CI -0.6-8.4; p = 0.09]), indicating no benefit-and trending toward decrement-to anticoagulation satisfaction. Change in anticoagulation satisfaction varied substantially following extended-interval monitoring, with no evidence of improved satisfaction. Plausible reasons for patients not preferring extended-interval monitoring include increased anxiety and disengagement from self-management activities, both potentially related to less frequent feedback and reassurance during extended interval-monitoring. Additional research is needed to identify who is likely to benefit most from extended-interval monitoring. Anticoagulation satisfaction should be considered with clinical factors and shared-decision making when implementing extended-interval warfarin monitoring.

  7. Digital radiography with computerized conventional monitors compared to medical monitors in vertical root fracture diagnosis.

    PubMed

    Tofangchiha, Maryam; Adel, Mamak; Bakhshi, Mahin; Esfehani, Mahsa; Nazeman, Pantea; Ghorbani Elizeyi, Mojgan; Javadi, Amir

    2013-01-01

    Vertical root fracture (VRF) is a complication which is chiefly diagnosed radiographically. Recently, film-based radiography has been substituted with digital radiography. At the moment, there is a wide range of monitors available in the market for viewing digital images. The present study aims to compare the diagnostic accuracy, sensitivity and specificity of medical and conventional monitors in detection of vertical root fractures. In this in vitro study 228 extracted single-rooted human teeth were endodontically treated. Vertical root fractures were induced in 114 samples. The teeth were imaged by a digital charge-coupled device radiography using parallel technique. The images were evaluated by a radiologist and an endodontist on two medical and conventional liquid-crystal display (LCD) monitors twice. Z-test was used to analyze the sensitivity, accuracy and specificity of each monitor. Significance level was set at 0.05. Inter and intra observer agreements were calculated by Cohen's kappa. Accuracy, specificity and sensitivity for conventional monitor were calculated as 67.5%, 72%, 62.5% respectively; and data for medical grade monitor were 67.5%, 66.5% and 68% respectively. Statistical analysis showed no significant differences in detecting VRF between the two techniques. Inter-observer agreement for conventional and medical monitor was 0.47 and 0.55 respectively (moderate). Intra-observer agreement was 0.78 for medical monitor and 0.87 for conventional one (substantial). The type of monitor does not influence diagnosis of vertical root fractures.

  8. Experiences of Self-Monitoring: Successes and Struggles during Treatment for Weight Loss

    PubMed Central

    Burke, Lora E.; Swigart, Valerie; Turk, Melanie Warziski; Derro, Nicole; Ewing, Linda J.

    2009-01-01

    We interviewed 15 individuals who completed a behavioral weight loss treatment study with the aim of exploring participants’ reflections on their feelings, attitudes and behaviors while using a paper diary to self-monitor their diet. Constant comparative and matrix analysis procedures were used to analyze interview data; the qualitative results were then interfaced with descriptive numerical data on individuals’ adherence to self-monitoring and weight loss. Three categories of self-monitoring experience were identified (a) Well-Disciplined – those who had high adherence to self-monitoring, high weight loss and a “can do” positive approach, (b) Missing the Connection – those who had moderate adherence, moderate to low weight loss, and an “it’s an assignment” approach without integrating self-monitoring into every day life, and (c) Diminished Support – those who had poor adherence, poor weight control, and were adversely affected by co-existing negative factors. Given the variations in how individuals integrated the process of self-monitoring, we need to consider individualizing self-monitoring strategies to improve adherence. PMID:19365099

  9. A Technical Evaluation of Wireless Connectivity from Patient Monitors to an Anesthesia Information Management System During Intensive Care Unit Surgery.

    PubMed

    Simpao, Allan F; Galvez, Jorge A; England, W Randall; Wartman, Elicia C; Scott, James H; Hamid, Michael M; Rehman, Mohamed A; Epstein, Richard H

    2016-02-01

    Surgical procedures performed at the bedside in the neonatal intensive care unit (NICU) at The Children's Hospital of Philadelphia were documented using paper anesthesia records in contrast to the operating rooms, where an anesthesia information management system (AIMS) was used for all cases. This was largely because of logistical problems related to connecting cables between the bedside monitors and our portable AIMS workstations. We implemented an AIMS for documentation in the NICU using wireless adapters to transmit data from bedside monitoring equipment to a portable AIMS workstation. Testing of the wireless AIMS during simulation in the presence of an electrosurgical generator showed no evidence of interference with data transmission. Thirty NICU surgical procedures were documented via the wireless AIMS. Two wireless cases exhibited brief periods of data loss; one case had an extended data gap because of adapter power failure. In comparison, in a control group of 30 surgical cases in which wired connections were used, there were no data gaps. The wireless AIMS provided a simple, unobtrusive, portable alternative to paper records for documenting anesthesia records during NICU bedside procedures.

  10. An extended multivariate framework for drought monitoring in Mexico

    NASA Astrophysics Data System (ADS)

    Real-Rangel, Roberto; Pedrozo-Acuña, Adrián; Breña-Naranjo, Agustín; Alcocer-Yamanaka, Víctor

    2017-04-01

    Around the world, monitoring natural hazards, such as droughts, represents a critical task in risk assessment and management plans. A reliable drought monitoring system allows to identify regions affected by these phenomena so that early response measures can be implemented. In Mexico, this activity is performed using Mexico's Drought Monitor, which is based on a similar methodology as the United States Drought Monitor and the North American Drought Monitor. The main feature of these monitoring systems is the combination of ground-based and remote sensing observations that is ultimately validated by local experts. However, in Mexico in situ records of variables such as precipitation and streamflow are often scarce, or even null, in many regions of the country. Another issue that adds uncertainty in drought monitoring is the arbitrary weight given to each analyzed variable. This study aims at providing an operational framework for drought monitoring in Mexico, based on univariate and multivariate nonparametric standardized indexes proposed in recent studies. Furthermore, the framework has been extended by taking into account the Enhanced Vegetation Index (EVI) for the drought severity assessment. The analyzed variables used for computing the drought indexes are mainly derived from remote sensing (MODIS) and land surface models datasets (NASA MERRA-2). A qualitative evaluation of the results shows that the indexes used are capable of adequately describes the intensity and spatial distribution of past drought documented events.

  11. [Design and implementation of real-time continuous glucose monitoring instrument].

    PubMed

    Huang, Yonghong; Liu, Hongying; Tian, Senfu; Jia, Ziru; Wang, Zi; Pi, Xitian

    2017-12-01

    Real-time continuous glucose monitoring can help diabetics to control blood sugar levels within the normal range. However, in the process of practical monitoring, the output of real-time continuous glucose monitoring system is susceptible to glucose sensor and environment noise, which will influence the measurement accuracy of the system. Aiming at this problem, a dual-calibration algorithm for the moving-window double-layer filtering algorithm combined with real-time self-compensation calibration algorithm is proposed in this paper, which can realize the signal drift compensation for current data. And a real-time continuous glucose monitoring instrument based on this study was designed. This real-time continuous glucose monitoring instrument consisted of an adjustable excitation voltage module, a current-voltage converter module, a microprocessor and a wireless transceiver module. For portability, the size of the device was only 40 mm × 30 mm × 5 mm and its weight was only 30 g. In addition, a communication command code algorithm was designed to ensure the security and integrity of data transmission in this study. Results of experiments in vitro showed that current detection of the device worked effectively. A 5-hour monitoring of blood glucose level in vivo showed that the device could continuously monitor blood glucose in real time. The relative error of monitoring results of the designed device ranged from 2.22% to 7.17% when comparing to a portable blood meter.

  12. [Intelligent videosurveillance and falls detection: Perceptions of professionals and managers].

    PubMed

    Lapierre, Nolwenn; Carpentier, Isabelle; St-Arnaud, Alain; Ducharme, Francine; Meunier, Jean; Jobidon, Mireille; Rousseau, Jacqueline

    2016-02-01

    Gerontechnologies can be used to detect accidental falls. However, existing systems do not entirely meet users' expectations. Our team developed an intelligent video-monitoring systems to fill these gaps. Authors advocate consulting potential users at the early stages of the design of gerontechnologies and integrating their suggestions. This study aims to explore health care workers' opinion regarding the intelligent video monitoring to detect falls by older adults living at home. This qualitative study explored the opinions of 31 participants using focus groups. Transcripts were analyzed using predetermined codes based on the competence model. Participants reported several advantages for using the intelligent video monitoring and provided suggestions for improving its use. The participants' suggestions and comments will help to improve the system and match it to users' needs. © CAOT 2015.

  13. Vital Recorder-a free research tool for automatic recording of high-resolution time-synchronised physiological data from multiple anaesthesia devices.

    PubMed

    Lee, Hyung-Chul; Jung, Chul-Woo

    2018-01-24

    The current anaesthesia information management system (AIMS) has limited capability for the acquisition of high-quality vital signs data. We have developed a Vital Recorder program to overcome the disadvantages of AIMS and to support research. Physiological data of surgical patients were collected from 10 operating rooms using the Vital Recorder. The basic equipment used were a patient monitor, the anaesthesia machine, and the bispectral index (BIS) monitor. Infusion pumps, cardiac output monitors, regional oximeter, and rapid infusion device were added as required. The automatic recording option was used exclusively and the status of recording was frequently checked through web monitoring. Automatic recording was successful in 98.5% (4,272/4,335) cases during eight months of operation. The total recorded time was 13,489 h (3.2 ± 1.9 h/case). The Vital Recorder's automatic recording and remote monitoring capabilities enabled us to record physiological big data with minimal effort. The Vital Recorder also provided time-synchronised data captured from a variety of devices to facilitate an integrated analysis of vital signs data. The free distribution of the Vital Recorder is expected to improve data access for researchers attempting physiological data studies and to eliminate inequalities in research opportunities due to differences in data collection capabilities.

  14. The Evolution and Application of Cardiac Monitoring for Occult Atrial Fibrillation in Cryptogenic Stroke and TIA.

    PubMed

    Miller, Daniel J; Shah, Kavit; Modi, Sumul; Mahajan, Abhimanyu; Zahoor, Salman; Affan, Muhammad

    2016-04-01

    The evaluation of the stroke and transient ischemic attack (TIA) patient has been historically predominated by the initial evaluation in the hospital setting. As the etiology of stroke has eluded us in approximately one third of all acute events, the medical community has been eager to seek the answer to this mystery. In recent years, we have seen an explosion of innovations and trends allowing for a more detailed post stroke assessment strategy aimed at the identification of occult atrial fibrillation as the etiologic cause for the cryptogenic event. This has been achieved through the evolution and aggressive application and study of prolonged and advanced cardiac monitoring. This review is aimed to clarify and elucidate the standard and novel cardiac monitoring methods that have become available for use by the medical community and expected in the higher level care of cryptogenic stroke and TIA patients. These cardiac monitoring methods and devices are as heterogeneous as our patient population and have their own advantages and disadvantages. Many factors may be taken into consideration in choosing the appropriate cardiac monitoring method and are highlighted for consideration in this review. With a judicious approach to investigating the cryptogenic stroke population, and applying a wealth of novel treatment options, we may move forward into a new era of stroke prevention.

  15. Space telescopes planetary monitoring (PM) and Zvezdny (eng. star) patrol (ZP) for planetary science and exoplanets exploration

    NASA Astrophysics Data System (ADS)

    Tavrov, Alexander; Frolov, Pavel; Korablev, Oleg; Vedenkin, Nikolai; Barabanov, Sergey

    2017-11-01

    Solar System planetology requires a wide use of observing spectroscopy for surface geology to atmosphere climatology. A high-contrast imaging is required to study and to characterize extra-solar planetary systems among other faint astronomical targets observed in the vicinity of bright objects. Two middle class space telescopes projects aimed to observe Solar system planets by a long term monitoring via spectroscopy and polarimetry. Extra solar planets (exoplanets) engineering and scientific explorations are included in science program.

  16. Opposite effects of cannabis and cocaine on performance monitoring.

    PubMed

    Spronk, Desirée B; Verkes, Robbert J; Cools, Roshan; Franke, Barbara; Van Wel, Janelle H P; Ramaekers, Johannes G; De Bruijn, Ellen R A

    2016-07-01

    Drug use is often associated with risky and unsafe behavior. However, the acute effects of cocaine and cannabis on performance monitoring processes have not been systematically investigated. The aim of the current study was to investigate how administration of these drugs alters performance monitoring processes, as reflected in the error-related negativity (ERN), the error positivity (Pe) and post-error slowing. A double-blind placebo-controlled randomized three-way crossover design was used. Sixty-one subjects completed a Flanker task while EEG measures were obtained. Subjects showed diminished ERN and Pe amplitudes after cannabis administration and increased ERN and Pe amplitudes after administration of cocaine. Neither drug affected post-error slowing. These results demonstrate diametrically opposing effects on the early and late phases of performance monitoring of the two most commonly used illicit drugs of abuse. Conversely, the behavioral adaptation phase of performance monitoring remained unaltered by the drugs. Copyright © 2016. Published by Elsevier B.V.

  17. Learning neuroendoscopy with an exoscope system (video telescopic operating monitor): Early clinical results.

    PubMed

    Parihar, Vijay; Yadav, Y R; Kher, Yatin; Ratre, Shailendra; Sethi, Ashish; Sharma, Dhananjaya

    2016-01-01

    Steep learning curve is found initially in pure endoscopic procedures. Video telescopic operating monitor (VITOM) is an advance in rigid-lens telescope systems provides an alternative method for learning basics of neuroendoscopy with the help of the familiar principle of microneurosurgery. The aim was to evaluate the clinical utility of VITOM as a learning tool for neuroendoscopy. Video telescopic operating monitor was used 39 cranial and spinal procedures and its utility as a tool for minimally invasive neurosurgery and neuroendoscopy for initial learning curve was studied. Video telescopic operating monitor was used in 25 cranial and 14 spinal procedures. Image quality is comparable to endoscope and microscope. Surgeons comfort improved with VITOM. Frequent repositioning of scope holder and lack of stereopsis is initial limiting factor was compensated for with repeated procedures. Video telescopic operating monitor is found useful to reduce initial learning curve of neuroendoscopy.

  18. Implementing AIM-based monitoring for natural resource management

    USDA-ARS?s Scientific Manuscript database

    Successful monitoring programs are built on clearly-defined objectives, thorough planning, and organized implementation. However, natural resource management decisions need to be made at many different organizational levels and scales – from local to national. Developing separate monitoring programs...

  19. Monitoring surface water quality using social media in the context of citizen science

    NASA Astrophysics Data System (ADS)

    Zheng, Hang; Hong, Yang; Long, Di; Jing, Hua

    2017-02-01

    Surface water quality monitoring (SWQM) provides essential information for water environmental protection. However, SWQM is costly and limited in terms of equipment and sites. The global popularity of social media and intelligent mobile devices with GPS and photography functions allows citizens to monitor surface water quality. This study aims to propose a method for SWQM using social media platforms. Specifically, a WeChat-based application platform is built to collect water quality reports from volunteers, which have been proven valuable for water quality monitoring. The methods for data screening and volunteer recruitment are discussed based on the collected reports. The proposed methods provide a framework for collecting water quality data from citizens and offer a primary foundation for big data analysis in future research.

  20. Why social science matters in river management: involvement of local stakeholders in monitoring the effects of room for the river measures in the Netherlands

    NASA Astrophysics Data System (ADS)

    Verbrugge, Laura; van den Born, Riyan

    2015-04-01

    The Netherlands is a densely populated delta region with a long tradition in flood protection and river management. In response to climate change, adaptive measures are implemented to create more room for the river (and thus increasing water discharge capacity) while at the same time maintaining the multifunctional use of the river system. These functions include for example navigation, water supply, housing and spatial quality, nature development and recreation. The incorporation of social aspects in water management is vital for the development and implementation of sustainable solutions in environmental planning. Active stakeholder involvement has major benefits in terms of trust, public support, social learning and creative decision making. In practice, however, stakeholder involvement is often confined to one-way communication (e.g. information on websites and public hearings) instead of establishing a dialogue with the relevant local stakeholders. Moreover, stakeholders are often involved too late. Our study focusses on stakeholder perceptions and the opportunities for stakeholder participation and collaboration in river management. One way to actively involve stakeholders and invest in a dialogue is through participatory monitoring, i.e. to involve local stakeholders in collecting, analyzing and evaluating monitoring data. Currently, a pilot engineering intervention (2013-2015) is carried out in the Waal river, i.e. the main Rhine branch in The Netherlands. This intervention comprises the substitution of traditional groynes by a 10 km longitudinal dam and will change the appearance of the fluvial landscape dramatically. An interdisciplinary team of scientists, government representatives and other public and private parties is involved in monitoring the hydrological, ecological and socio-economic effects of the longitudinal dam with the aim to develop and improve models, guidelines and tools for integrative river management. This also provides unique opportunities for stakeholder involvement. Within this project, a pilot for participatory monitoring is initiated for three important stakeholder groups: local residents, recreational anglers and boaters, and those working in the inland shipping industry. Our study aims (1) to unfold stakeholder perceptions with respect to the longitudinal dam, (2) to explore how and to what extent local stakeholders can be involved in the monitoring program and (3) to carry out a pilot project for participatory monitoring. For each stakeholder group we will discuss survey results regarding their perceptions, as well as the possibilities for participatory monitoring. In cases where involvement in monitoring is not a feasible option, we will advise on alternative forms of public participation. Overall, we stress the importance of stakeholder involvement and aim to identify optimal ways for public participation in river management.

  1. Integrated photovoltaic (PV) monitoring system

    NASA Astrophysics Data System (ADS)

    Mahinder Singh, Balbir Singh; Husain, NurSyahidah; Mohamed, Norani Muti

    2012-09-01

    The main aim of this research work is to design an accurate and reliable monitoring system to be integrated with solar electricity generating system. The performance monitoring system is required to ensure that the PVEGS is operating at an optimum level. The PV monitoring system is able to measure all the important parameters that determine an optimum performance. The measured values are recorded continuously, as the data acquisition system is connected to a computer, and data is stored at fixed intervals. The data can be locally used and can also be transmitted via internet. The data that appears directly on the local monitoring system is displayed via graphical user interface that was created by using Visual basic and Apache software was used for data transmission The accuracy and reliability of the developed monitoring system was tested against the data that captured simultaneously by using a standard power quality analyzer device. The high correlation which is 97% values indicates the level of accuracy of the monitoring system. The aim of leveraging on a system for continuous monitoring system is achieved, both locally, and can be viewed simultaneously at a remote system.

  2. Smartphone-Based Monitoring of Objective and Subjective Data in Affective Disorders: Where Are We and Where Are We Going? Systematic Review.

    PubMed

    Dogan, Ezgi; Sander, Christian; Wagner, Xenija; Hegerl, Ulrich; Kohls, Elisabeth

    2017-07-24

    Electronic mental health interventions for mood disorders have increased rapidly over the past decade, most recently in the form of various systems and apps that are delivered via smartphones. We aim to provide an overview of studies on smartphone-based systems that combine subjective ratings with objectively measured data for longitudinal monitoring of patients with affective disorders. Specifically, we aim to examine current knowledge on: (1) the feasibility of, and adherence to, such systems; (2) the association of monitored data with mood status; and (3) the effects of monitoring on clinical outcomes. We systematically searched PubMed, Web of Science, PsycINFO, and the Cochrane Central Register of Controlled Trials for relevant articles published in the last ten years (2007-2017) by applying Boolean search operators with an iterative combination of search terms, which was conducted in February 2017. Additional articles were identified via pearling, author correspondence, selected reference lists, and trial protocols. A total of 3463 unique records were identified. Twenty-nine studies met the inclusion criteria and were included in the review. The majority of articles represented feasibility studies (n=27); two articles reported results from one randomized controlled trial (RCT). In total, six different self-monitoring systems for affective disorders that used subjective mood ratings and objective measurements were included. These objective parameters included physiological data (heart rate variability), behavioral data (phone usage, physical activity, voice features), and context/environmental information (light exposure and location). The included articles contained results regarding feasibility of such systems in affective disorders, showed reasonable accuracy in predicting mood status and mood fluctuations based on the objectively monitored data, and reported observations about the impact of monitoring on clinical state and adherence of patients to the system usage. The included observational studies and RCT substantiate the value of smartphone-based approaches for gathering long-term objective data (aside from self-ratings to monitor clinical symptoms) to predict changes in clinical states, and to investigate causal inferences about state changes in patients with affective disorders. Although promising, a much larger evidence-base is necessary to fully assess the potential and the risks of these approaches. Methodological limitations of the available studies (eg, small sample sizes, variations in the number of observations or monitoring duration, lack of RCT, and heterogeneity of methods) restrict the interpretability of the results. However, a number of study protocols stated ambitions to expand and intensify research in this emerging and promising field. ©Ezgi Dogan, Christian Sander, Xenija Wagner, Ulrich Hegerl, Elisabeth Kohls. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 24.07.2017.

  3. Continuous noninvasive monitoring in the neonatal ICU.

    PubMed

    Sahni, Rakesh

    2017-04-01

    Standard hemodynamic monitoring such as heart rate and systemic blood pressure may only provide a crude estimation of organ perfusion during neonatal intensive care. Pulse oximetry monitoring allows for continuous noninvasive monitoring of hemoglobin oxygenation and thus provides estimation of end-organ oxygenation. This review aims to provide an overview of pulse oximetry and discuss its current and potential clinical use during neonatal intensive care. Technological advances in continuous assessment of dynamic changes in systemic oxygenation with pulse oximetry during transition to extrauterine life and beyond provide additional details about physiological interactions among the key hemodynamic factors regulating systemic blood flow distribution along with the subtle changes that are frequently transient and undetectable with standard monitoring. Noninvasive real-time continuous systemic oxygen monitoring has the potential to serve as biomarkers for early-organ dysfunction, to predict adverse short-term and long-term outcomes in critically ill neonates, and to optimize outcomes. Further studies are needed to establish values predicting adverse outcomes and to validate targeted interventions to normalize abnormal values to improve outcomes.

  4. Review of oil and HNS accidental spills in Europe: identifying major environmental monitoring gaps and drawing priorities.

    PubMed

    Neuparth, T; Moreira, S M; Santos, M M; Reis-Henriques, M A

    2012-06-01

    The European Atlantic area has been the scene of a number of extensive shipping incidents with immediate and potential long-term impacts to marine ecosystems. The occurrence of accidental spills at sea requires an effective response that must include a well executed monitoring programme to assess the environmental contamination and damage of the affected marine habitats. Despite a number of conventions and protocols developed by international and national authorities that focused on the preparedness and response to oil and HNS spills, much remains to be done, particularly in relation to the effectiveness of the environmental monitoring programmes implemented after oil and HNS spills. Hence, the present study reviews the status of the environmental monitoring programmes established following the major spill incidents over the last years in European waters, aiming at identifying the key monitoring gaps and drawing priorities for an effective environmental monitoring of accidental spills. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. Orbital Sciences Pegasus XL AIM Processing

    NASA Image and Video Library

    2007-03-16

    In a clean-room environment at North Vandenberg Air Force Base, a technician monitors the AIM spacecraft after illumination testing on the spacecraft's solar array panels. The AIM spacecraft will fly three instruments designed to study those clouds located at the edge of space, 50 miles above the Earth's surface in the coldest part of the planet's atmosphere. The mission's primary goal is to explain why these clouds form and what has caused them to become brighter and more numerous and appear at lower latitudes in recent years. AIM's results will provide the basis for the study of long-term variability in the mesospheric climate and its relationship to global climate change. AIM is scheduled to be mated to the Pegasus XL during the second week of April, after which final inspections will be conducted. Launch is scheduled for April 25.

  6. Phase-I monitoring of standard deviations in multistage linear profiles

    NASA Astrophysics Data System (ADS)

    Kalaei, Mahdiyeh; Soleimani, Paria; Niaki, Seyed Taghi Akhavan; Atashgar, Karim

    2018-03-01

    In most modern manufacturing systems, products are often the output of some multistage processes. In these processes, the stages are dependent on each other, where the output quality of each stage depends also on the output quality of the previous stages. This property is called the cascade property. Although there are many studies in multistage process monitoring, there are fewer works on profile monitoring in multistage processes, especially on the variability monitoring of a multistage profile in Phase-I for which no research is found in the literature. In this paper, a new methodology is proposed to monitor the standard deviation involved in a simple linear profile designed in Phase I to monitor multistage processes with the cascade property. To this aim, an autoregressive correlation model between the stages is considered first. Then, the effect of the cascade property on the performances of three types of T 2 control charts in Phase I with shifts in standard deviation is investigated. As we show that this effect is significant, a U statistic is next used to remove the cascade effect, based on which the investigated control charts are modified. Simulation studies reveal good performances of the modified control charts.

  7. Pacemaker remote monitoring in the pediatric population: is it a real solution?

    PubMed

    Leoni, Loira; Padalino, Massimo; Biffanti, Roberta; Ferretto, Sonia; Vettor, Giulia; Corrado, Domenico; Stellin, Giovanni; Milanesi, Ornella; Iliceto, Sabino

    2015-05-01

    Clinical utility of remote monitoring of implantable cardiac devices has been previously demonstrated in several trials in the adult population. The aim of this study was to assess the clinical utility of remote monitoring in a pediatric population undergoing pacemakers implantation. The study population included 73 consecutive pediatric patients who received an implantable pacemaker. The remote device check was programmed for every 3 months and all patients had a yearly out-patient visit. Data on device-related events, hospitalization, and other clinical information were collected during remote checks and out-patient visits. During a mean follow-up of 18 ± 10 months, 470 remote transmissions were collected and analyzed. Two deaths were reported. Eight transmissions (1.7%) triggered an urgent out-patient visit. Twenty percent of transmissions reported evidence of significant clinical or technical events. All young patients and their families were very satisfied when using remote monitoring to replace out-patient visits. The ease in use, together with satisfaction and acceptance of remote monitoring in pediatric patients, brought very good results. The remote management of our pediatric population was safe and remote monitoring adequately replaced the periodic out-patient device checks without compromising patient safety. ©2015 Wiley Periodicals, Inc.

  8. A brief intervention changing oral self-care, self-efficacy, and self-monitoring.

    PubMed

    Schwarzer, Ralf; Antoniuk, Agata; Gholami, Maryam

    2015-02-01

    The roles of self-efficacy and self-monitoring as proximal predictors of dental flossing frequency are studied in the context of an oral health intervention. A study among 287 university students, aged 19 to 26 years, compared an intervention group that received a brief self-regulatory treatment, with a passive and an active control group. Dental flossing, self-efficacy, and self-monitoring were assessed at baseline and 3 weeks later. The intervention led to an increase in dental flossing regardless of experimental condition. However, treatment-specific gains were documented for self-efficacy and self-monitoring. Moreover, changes in the latter two served as mediators in a path model, linking the intervention with subsequent dental flossing and yielding significant indirect effects. Self-efficacy and self-monitoring play a mediating role in facilitating dental flossing. Interventions that aim at an improvement in oral self-care should consider using these constructs. Statement of contribution What is already known on this subject? The adoption and maintenance of oral self-care can be facilitated by a number of social-cognitive variables. Interventions that include planning, action control, or self-efficacy components have been shown to improve dental flossing. In one recent study on flossing in adolescent girls, planning intervention effects were mediated by self-efficacy. What does this study add? Self-monitoring is associated with better oral self-care. A 10-min intervention improves self-efficacy and self-monitoring. Self-efficacy and self-monitoring operate as mediators between treatment and flossing. © 2014 The British Psychological Society.

  9. Evaluation of the appropriateness and outcome of in-hospital telemetry monitoring.

    PubMed

    Fålun, Nina; Nordrehaug, Jan Erik; Hoff, Per Ivar; Langørgen, Jørund; Moons, Philip; Norekvål, Tone M

    2013-10-15

    The American Heart Association classifies monitored patients into 3 categories. The aims of this study were to (1) investigate how patients are assigned according to the American Heart Association classification, (2) determine the number and type of arrhythmic events experienced by these patients, and (3) describe subsequent changes in management. A prospective observational study design was used. All patients assigned to telemetry during a 3-month period were consecutively enrolled in our study. Data were collected 24/7. Only arrhythmias that might require a change in management were recorded. Monitor watchers at the central monitoring station completed a standard data sheet assessing 64 variables. These data, as well as medical records, were reviewed by the investigator. Overall, 1,194 patients were included. Eighteen percent of the patients were assigned to American Heart Association class I (monitoring indicated), 71% to class II (monitoring may be of benefit), and 11% to class III (monitoring not indicated). The overall arrhythmia event rate was 33%. Forty-three percent of class I patients, 28% of class II patients, and 47% of class III patients experienced arrhythmia events. Change in management occurred in 25% of class I patients, 14% of class II patients, and 29% of class III patients. Although the number of class III indications should have been reduced, nearly 1/2 of class III patients experienced arrhythmia events and 1/3 of them received management changes. This outcome challenges existing guidelines. In conclusion, most patients in this study were monitored appropriately, according to class I and II indications. Copyright © 2013 Elsevier Inc. All rights reserved.

  10. Miniaturized Monitors for Assessment of Exposure to Air Pollutants: A Review.

    PubMed

    Borghi, Francesca; Spinazzè, Andrea; Rovelli, Sabrina; Campagnolo, Davide; Del Buono, Luca; Cattaneo, Andrea; Cavallo, Domenico M

    2017-08-12

    Air quality has a huge impact on different aspects of life quality, and for this reason, air quality monitoring is required by national and international regulations. Technical and procedural limitations of traditional fixed-site stations for monitoring or sampling of air pollutants are also well-known. Recently, a different type of miniaturized monitors has been developed. These monitors, due to their characteristics (e.g., low cost, small size, high portability) are becoming increasingly important for individual exposure assessment, especially since this kind of instrument can provide measurements at high spatial and temporal resolution, which is a notable advantage when approaching assessment of exposure to environmental contaminants. The aim of this study is indeed to provide information regarding current knowledge regarding the use of miniaturized air pollutant sensors. A systematic review was performed to identify original articles: a literature search was carried out using an appropriate query for the search of papers across three different databases, and the papers were selected using inclusion/exclusion criteria. The reviewed articles showed that miniaturized sensors are particularly versatile and could be applied in studies with different experimental designs, helping to provide a significant enhancement to exposure assessment, even though studies regarding their performance are still sparse.

  11. Embolic Signals during Routine Transcranial Doppler Ultrasonography in Aneurysmal Subarachnoid Hemorrhage

    PubMed Central

    Paschoal, Fernando Mendes; de Almeida Lins Ronconi, Karla; de Lima Oliveira, Marcelo; Nogueira, Ricardo de Carvalho; Paschoal, Eric Homero Albuquerque; Teixeira, Manoel Jacobsen; Figueiredo, Eberval Gadelha; Bor-Seng-Shu, Edson

    2015-01-01

    Introduction. Cerebral emboli may occur in subarachnoid hemorrhage (SAH) and intracranial aneurysm surgery. Although embolic signs (ES) have been reported in SAH, their origin remains unclear. The aim of this study was to report the detection of ES during routine TCD monitoring in patients with aneurysmal SAH. Methods. A total of 105 patients with aneurysmal SAH were submitted to TCD evaluation. Patients were monitored almost daily (5 times per week). In each monitoring session, one experienced operator performed TCD to detect or assess vasospasm and ES in arteries of the Willis polygon. Results. Four patients out of a total of 105 patients with aneurysmal SAH were found to present spontaneous cerebral embolization during routine TCD monitoring. The average age of the 4 patients (mean ± standard deviation) was 59.5 ± 8.34 years (range 49–68 ys); female patients predominated representing 75% (3/4) of subjects. Conclusion. Although detection of ES was relatively rare in this study, rates of emboli occurrence may be higher under systematic monitoring. The detection of ES after SAH surgery reinforces the need to study the role of embolus in this condition and may be an indicator for prophylactic antithrombotic treatment. PMID:25893190

  12. A Longitudinal Study on the Effects of Parental Monitoring on Adolescent Antisocial Behaviors: The Moderating Role of Adolescent Empathy

    PubMed Central

    Crocetti, Elisabetta; Van der Graaff, Jolien; Moscatelli, Silvia; Keijsers, Loes; Koot, Hans M.; Rubini, Monica; Meeus, Wim; Branje, Susan

    2016-01-01

    In adolescence, youth antisocial behaviors reach a peak. Parents can use different strategies, such as parental solicitation and control, to monitor their children’s activities and try to prevent or reduce their antisocial behaviors. However, it is still unclear if, and for which adolescents, these parental monitoring behaviors are effective. The aim of this study was to examine if the impact of parental solicitation and control on adolescent antisocial behaviors depends on adolescent empathy. In order to comprehensively address this aim, we tested the moderating effects of multiple dimensions (affective and cognitive) of both trait and state empathy. Participants were 379 Dutch adolescents (55.9% males) involved in a longitudinal study with their fathers and mothers. At T1 (conducted when adolescents were 17-year-old) adolescents filled self-report measures of antisocial behaviors and trait empathy during one home visit, while their state empathy was rated during a laboratory session. Furthermore, parents reported their own monitoring behaviors. At T2 (conducted 1 year later, when adolescents were 18-year-old), adolescents reported again on their antisocial behaviors. Moderation analyses indicated that both affective and cognitive state empathy moderated the effects of parental solicitation on adolescent antisocial behaviors. Results highlighted that solicitation had unfavorable effects on antisocial behaviors in adolescents with high empathy whereas the opposite effect was found for adolescents with low empathy. In contrast, neither state nor trait empathy moderated the effects of control on adolescent antisocial behaviors. Theoretical and practical implications of these findings are discussed. PMID:27857703

  13. Optical monitoring of cerebral microcirculation in neurointensive care.

    PubMed

    Rejmstad, Peter; Haj-Hosseini, Neda; Åneman, Oscar; Wårdell, Karin

    2017-12-08

    Continuous optical monitoring of local cerebral microcirculation could benefit neurointensive care patients treated for subarachnoid hemorrhage (SAH). The aim of the study was to evaluate laser Doppler flowmetry (LDF) and diffuse reflectance spectroscopy (DRS) for long-term monitoring of brain microcirculation and oxygen saturation (SO 2 ) in the neurointensive care unit (NICU). A fiber optic probe was designed for intraparenchymal use and connected to LDF and DRS for assessment of the local blood flow (perfusion and tissue reflectance (TLI)) and SO 2 in the brain. The optically monitored parameters were compared with conventional NICU monitors and Xe-CT. The LDF signals were low with median and 25 to 75% interquartiles of perfusion = 70 (59 to 83) a.u. and TLI = 2.0 (1.0 to 2.4) a.u. and showed correlation with the NICU monitors in terms of heart rate. Median and interquartiles of SO 2 were 17.4 (15.7 to 19.8) %. The lack of correlation between local perfusion and cerebral perfusion pressure indicated intact cerebral autoregulation. The systems were capable of monitoring both local perfusion and SO 2 with stable signals in the NICU over 4 days. Further clinical studies are required to evaluate the optical systems' potential for assessing the onset of secondary brain injury.

  14. Signal loss during fetal heart rate monitoring using maternal abdominal surface electrodes between 28 and 42 weeks of pregnancy.

    PubMed

    Fuchs, Tomasz; Pomorski, Michał; Grobelak, Krzysztof; Tomiałowicz, Marek; Zimmer, Mariusz

    2014-01-01

    Fetal electrocardiography is one of the methods for monitoring the well-being of the fetus. Signal loss limits the proper interpretation of electrocardiogram traces. The aim of this study was to assess the average signal loss in non-invasive abdominal fetal electrocardiogram (fECG) monitoring using the KOMPOREL fetal monitoring system (ITAM, Zabrze, Poland) in women between 28 and 42 week of pregnancy. The results were compared to FIGO (International Federation of Gynaecology and Obstetric) and DGGG (Deutsche Gesellschaft für Gynäkologie und Geburtshilfe e.V.) recommendations concerning fetal heart monitoring. The correlation between fetal ECG signal quality, week of pregnancy and patient BMI was evaluated. 773 pregnant women, hospitalized and diagnosed in the Department of Gynecology and Obstetrics, Wroclaw Medical University, underwent 30 min of abdominal fECG recordings using the KOMPOREL fetal monitoring system. The average signal loss in abdominal fECG monitoring in the study group was 32%. FIGO recommendations describe an acceptable fetal signal loss of 20%. In our study, 46% (357/773) of the recordings were up to FIGO standards, with fetal heart rate success rates above 80%. According to DGGG guidelines, with acceptable fetal signal loss of 15%, only 39% (303/773) of the recordings could be assessed as accurate. No correlation between fECG signal quality, week of pregnancy and patient BMI was proved. The average signal loss in abdominal fECG monitoring in our study group was 32%. Low fECG signal quality may constitute a potentially limiting factor of the described fetal heart monitoring system. No relationship between fECG signal quality, week of pregnancy and patient BMI was proved.

  15. Improvement of in-hospital telemetry monitoring in coronary care units: an intervention study for achieving optimal electrode placement and attachment, hygiene and delivery of critical information to patients.

    PubMed

    Pettersen, Trond R; Fålun, Nina; Norekvål, Tone M

    2014-12-01

    In-hospital telemetry monitoring is important for diagnosis and treatment of patients at risk of developing life-threatening arrhythmias. It is widely used in critical and non-critical care wards. Nurses are responsible for correct electrode placement, thus ensuring optimal quality of the monitoring. The aims of this study were to determine whether a complex educational intervention improves (a) optimal electrode placement, (b) hygiene, and (c) delivery of critical information to patients (reason for monitoring, limitations in cellular phone use, and not to leave the ward without informing a member of staff). A prospective interventional study design was used, with data collection occurring over two six-week periods: before implementation of the intervention (n=201) and after the intervention (n=165). Standard abstraction forms were used to obtain data on patients' clinical characteristics, and 10 variables related to electrode placement and attachment, hygiene and delivery of critical information. At pre-intervention registration, 26% of the electrodes were misplaced. Twelve per cent of the patients received information about limiting their cellular phone use while monitored, 70% were informed of the purpose of monitoring, and 71% used a protective cover for their unit. Post-intervention, outcome measures for the three variables improved significantly: use of protective cover (p<0.001), information about the purpose of monitoring (p=0.005) and information about limitations in cellular phone use (p=0.003). Nonetheless, 23% of the electrodes were still misplaced. The study highlights the need for better, continued education for in-hospital telemetry monitoring in coronary care units, and other units that monitor patients with telemetry. © The European Society of Cardiology 2013.

  16. Monitoring Wetlands Area Using Microwave, Optical And In-Situ Data

    NASA Astrophysics Data System (ADS)

    Dabrowska, Katarzyna; Zielinska, Maria Budzynska

    2011-01-01

    The study of Wetlands has been continue within the PECS Project: “Study and implement remote sensing techniques for the assessment of carbon balances for different biomasses and soil moistures within various ecosystems”. The research has been conducted in Biebrza valley, one of the largest wetland in Europe, since 2003. Recently, to existing data base of wetlands monitoring Carbon flux measurements using the Chamber Method and Eddy Correlation Method have been included. The study aims at monitoring and mapping various soil-vegetation variables and the assessment of the level of carbon balance using optical and microwave satellite data along with ground truth observations. Optical images have been used for classification of wetlands vegetation and calculation of LAI and biomass. For the assessment of water balance, energy budget approach has been applied. Microwave images have been used for the assessment of soil moisture and biomass.

  17. Community assessment of tropical tree biomass: challenges and opportunities for REDD.

    PubMed

    Theilade, Ida; Rutishauser, Ervan; Poulsen, Michael K

    2015-12-01

    REDD+ programs rely on accurate forest carbon monitoring. Several REDD+ projects have recently shown that local communities can monitor above ground biomass as well as external professionals, but at lower costs. However, the precision and accuracy of carbon monitoring conducted by local communities have rarely been assessed in the tropics. The aim of this study was to investigate different sources of error in tree biomass measurements conducted by community monitors and determine the effect on biomass estimates. Furthermore, we explored the potential of local ecological knowledge to assess wood density and botanical identification of trees. Community monitors were able to measure tree DBH accurately, but some large errors were found in girth measurements of large and odd-shaped trees. Monitors with experience from the logging industry performed better than monitors without previous experience. Indeed, only experienced monitors were able to discriminate trees with low wood densities. Local ecological knowledge did not allow consistent tree identification across monitors. Future REDD+ programmes may benefit from the systematic training of local monitors in tree DBH measurement, with special attention given to large and odd-shaped trees. A better understanding of traditional classification systems and concepts is required for local tree identifications and wood density estimates to become useful in monitoring of biomass and tree diversity.

  18. Integration of Centrifuge Testing in Undergraduate Geotechnical Engineering Education at Remote Campuses

    ERIC Educational Resources Information Center

    El Shamy, Usama; Abdoun, Tarek; McMartin, Flora; Pando, Miguel A.

    2013-01-01

    We report the results of a pilot study aimed at developing, implementing, and assessing an educational module that integrates remote major research instrumentation into undergraduate classes. Specifically, this study employs Internet Web-based technologies to allow for real-time video monitoring and execution of cutting-edge experiments. The…

  19. Direct Instruction of Metacognition Benefits Adolescent Science Learning, Transfer, and Motivation: An In Vivo Study

    ERIC Educational Resources Information Center

    Zepeda, Cristina D.; Richey, J. Elizabeth; Ronevich, Paul; Nokes-Malach, Timothy J.

    2015-01-01

    Prior studies have not tested whether an instructional intervention aimed at improving metacognitive skills results in changes to student metacognition, motivation, learning, and future learning in the classroom. We examined whether a 6-hr intervention designed to teach the declarative and procedural components of planning, monitoring, and…

  20. Development of Active Control within Working Memory: Active Retrieval versus Monitoring in Children

    ERIC Educational Resources Information Center

    Blain-Brière, Bénédicte; Bouchard, Caroline; Bigras, Nathalie; Cadoret, Geneviève

    2014-01-01

    This study aimed to compare children's performance on two mnemonic functions that engage the lateral prefrontal cortex. Brain imaging studies in adults have shown that the mid-ventrolateral prefrontal cortex is specifically involved in active controlled retrieval, and the mid-dorsolateral prefrontal cortex is specifically involved in monitoring…

  1. Exploring the Relationship between Teachers' Participation in Modified Lesson Study Cycles and Their Implementation of High-Level Tasks

    ERIC Educational Resources Information Center

    Eskelson, Samuel L.

    2013-01-01

    This study explored the relationship between mathematics teachers' participation in professional development and subsequent changes in their instructional practices. This professional development aimed to help teachers to implement high-level tasks through the use of the "five practices": anticipating, monitoring, selecting, and…

  2. Non-Selective Lexical Access in Different-Script Bilinguals

    ERIC Educational Resources Information Center

    Moon, Jihye; Jiang, Nan

    2012-01-01

    Lexical access in bilinguals is known to be largely non-selective. However, most studies in this area have involved bilinguals whose two languages share the same script. This study aimed to examine bilingual lexical access among bilinguals whose two languages have distinct scripts. Korean-English bilinguals were tested in a phoneme monitoring task…

  3. The Automated Instrumentation and Monitoring System (AIMS) reference manual

    NASA Technical Reports Server (NTRS)

    Yan, Jerry; Hontalas, Philip; Listgarten, Sherry

    1993-01-01

    Whether a researcher is designing the 'next parallel programming paradigm,' another 'scalable multiprocessor' or investigating resource allocation algorithms for multiprocessors, a facility that enables parallel program execution to be captured and displayed is invaluable. Careful analysis of execution traces can help computer designers and software architects to uncover system behavior and to take advantage of specific application characteristics and hardware features. A software tool kit that facilitates performance evaluation of parallel applications on multiprocessors is described. The Automated Instrumentation and Monitoring System (AIMS) has four major software components: a source code instrumentor which automatically inserts active event recorders into the program's source code before compilation; a run time performance-monitoring library, which collects performance data; a trace file animation and analysis tool kit which reconstructs program execution from the trace file; and a trace post-processor which compensate for data collection overhead. Besides being used as prototype for developing new techniques for instrumenting, monitoring, and visualizing parallel program execution, AIMS is also being incorporated into the run-time environments of various hardware test beds to evaluate their impact on user productivity. Currently, AIMS instrumentors accept FORTRAN and C parallel programs written for Intel's NX operating system on the iPSC family of multi computers. A run-time performance-monitoring library for the iPSC/860 is included in this release. We plan to release monitors for other platforms (such as PVM and TMC's CM-5) in the near future. Performance data collected can be graphically displayed on workstations (e.g. Sun Sparc and SGI) supporting X-Windows (in particular, Xl IR5, Motif 1.1.3).

  4. On valuing information in adaptive-management models.

    PubMed

    Moore, Alana L; McCarthy, Michael A

    2010-08-01

    Active adaptive management looks at the benefit of using strategies that may be suboptimal in the near term but may provide additional information that will facilitate better management in the future. In many adaptive-management problems that have been studied, the optimal active and passive policies (accounting for learning when designing policies and designing policy on the basis of current best information, respectively) are very similar. This seems paradoxical; when faced with uncertainty about the best course of action, managers should spend very little effort on actively designing programs to learn about the system they are managing. We considered two possible reasons why active and passive adaptive solutions are often similar. First, the benefits of learning are often confined to the particular case study in the modeled scenario, whereas in reality information gained from local studies is often applied more broadly. Second, management objectives that incorporate the variance of an estimate may place greater emphasis on learning than more commonly used objectives that aim to maximize an expected value. We explored these issues in a case study of Merri Creek, Melbourne, Australia, in which the aim was to choose between two options for revegetation. We explicitly incorporated monitoring costs in the model. The value of the terminal rewards and the choice of objective both influenced the difference between active and passive adaptive solutions. Explicitly considering the cost of monitoring provided a different perspective on how the terminal reward and management objective affected learning. The states for which it was optimal to monitor did not always coincide with the states in which active and passive adaptive management differed. Our results emphasize that spending resources on monitoring is only optimal when the expected benefits of the options being considered are similar and when the pay-off for learning about their benefits is large.

  5. Structural health monitoring of pipelines rehabilitated with lining technology

    NASA Astrophysics Data System (ADS)

    Farhidzadeh, Alireza; Dehghan-Niri, Ehsan; Salamone, Salvatore

    2014-03-01

    Damage detection of pipeline systems is a tedious and time consuming job due to digging requirement, accessibility, interference with other facilities, and being extremely wide spread in metropolitans. Therefore, a real-time and automated monitoring system can pervasively reduce labor work, time, and expenditures. This paper presents the results of an experimental study aimed at monitoring the performance of full scale pipe lining systems, subjected to static and dynamic (seismic) loading, using Acoustic Emission (AE) technique and Guided Ultrasonic Waves (GUWs). Particularly, two damage mechanisms are investigated: 1) delamination between pipeline and liner as the early indicator of damage, and 2) onset of nonlinearity and incipient failure of the liner as critical damage state.

  6. Smartphone based monitoring system for long-term sleep assessment.

    PubMed

    Domingues, Alexandre

    2015-01-01

    The diagnosis of sleep disorders, highly prevalent in Western countries, typically involves sophisticated procedures and equipment that are highly intrusive to the patient. The high processing capabilities and storage capacity of current portable devices, together with a big range of available sensors, many of them with wireless capabilities, create new opportunities and change the paradigms in sleep studies. In this work, a smartphone based sleep monitoring system is presented along with the details of the hardware, software and algorithm implementation. The aim of this system is to provide a way for subjects, with no pre-diagnosed sleep disorders, to monitor their sleep habits, and on the initial screening of abnormal sleep patterns.

  7. Immune Monitoring for CMV in Transplantation.

    PubMed

    Yong, Michelle K; Lewin, Sharon R; Manuel, Oriol

    2018-03-14

    Immune monitoring to determine when and how the recovery of cytomegalovirus (CMV)-specific T-cells occurs post-transplantation may help clinicians to risk stratify individuals at risk of complications from CMV. We aimed to review all recent clinical studies using CMV immune monitoring in the pre- and post-transplant setting including the use of recently developed standardized assays (Quantiferon-CMV and the CMV ELISPOT) to better understand in whom, when, and how immune monitoring is best used. Pre-transplant assessment of CMV immunity in solid-organ transplant recipients where CMV seropositive recipients had undetectable cell-mediated responses despite past immunity has shown that they are at a much higher risk of developing CMV reactivation. Post-transplant CMV immune monitoring can guide (shorten or prolong) the duration of antiviral prophylaxis, identify recipients at risk of post-prophylaxis CMV disease, and predict recurrent CMV reactivation. Thus, CMV immune monitoring, in addition to current clinical and DNA-based monitoring for CMV, has the potential to be incorporated into routine clinical care to better improve CMV management in both the stem and solid-organ transplant population.

  8. A component-based system for agricultural drought monitoring by remote sensing.

    PubMed

    Dong, Heng; Li, Jun; Yuan, Yanbin; You, Lin; Chen, Chao

    2017-01-01

    In recent decades, various kinds of remote sensing-based drought indexes have been proposed and widely used in the field of drought monitoring. However, the drought-related software and platform development lag behind the theoretical research. The current drought monitoring systems focus mainly on information management and publishing, and cannot implement professional drought monitoring or parameter inversion modelling, especially the models based on multi-dimensional feature space. In view of the above problems, this paper aims at fixing this gap with a component-based system named RSDMS to facilitate the application of drought monitoring by remote sensing. The system is designed and developed based on Component Object Model (COM) to ensure the flexibility and extendibility of modules. RSDMS realizes general image-related functions such as data management, image display, spatial reference management, image processing and analysis, and further provides drought monitoring and evaluation functions based on internal and external models. Finally, China's Ningxia region is selected as the study area to validate the performance of RSDMS. The experimental results show that RSDMS provide an efficient and scalable support to agricultural drought monitoring.

  9. A component-based system for agricultural drought monitoring by remote sensing

    PubMed Central

    Yuan, Yanbin; You, Lin; Chen, Chao

    2017-01-01

    In recent decades, various kinds of remote sensing-based drought indexes have been proposed and widely used in the field of drought monitoring. However, the drought-related software and platform development lag behind the theoretical research. The current drought monitoring systems focus mainly on information management and publishing, and cannot implement professional drought monitoring or parameter inversion modelling, especially the models based on multi-dimensional feature space. In view of the above problems, this paper aims at fixing this gap with a component-based system named RSDMS to facilitate the application of drought monitoring by remote sensing. The system is designed and developed based on Component Object Model (COM) to ensure the flexibility and extendibility of modules. RSDMS realizes general image-related functions such as data management, image display, spatial reference management, image processing and analysis, and further provides drought monitoring and evaluation functions based on internal and external models. Finally, China’s Ningxia region is selected as the study area to validate the performance of RSDMS. The experimental results show that RSDMS provide an efficient and scalable support to agricultural drought monitoring. PMID:29236700

  10. Online Removal of Baseline Shift with a Polynomial Function for Hemodynamic Monitoring Using Near-Infrared Spectroscopy.

    PubMed

    Zhao, Ke; Ji, Yaoyao; Li, Yan; Li, Ting

    2018-01-21

    Near-infrared spectroscopy (NIRS) has become widely accepted as a valuable tool for noninvasively monitoring hemodynamics for clinical and diagnostic purposes. Baseline shift has attracted great attention in the field, but there has been little quantitative study on baseline removal. Here, we aimed to study the baseline characteristics of an in-house-built portable medical NIRS device over a long time (>3.5 h). We found that the measured baselines all formed perfect polynomial functions on phantom tests mimicking human bodies, which were identified by recent NIRS studies. More importantly, our study shows that the fourth-order polynomial function acted to distinguish performance with stable and low-computation-burden fitting calibration (R-square >0.99 for all probes) among second- to sixth-order polynomials, evaluated by the parameters R-square, sum of squares due to error, and residual. This study provides a straightforward, efficient, and quantitatively evaluated solution for online baseline removal for hemodynamic monitoring using NIRS devices.

  11. MO-FG-CAMPUS-JeP3-04: Feasibility Study of Real-Time Ultrasound Monitoring for Abdominal Stereotactic Body Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Su, Lin; Kien Ng, Sook; Zhang, Ying

    Purpose: Ultrasound is ideal for real-time monitoring in radiotherapy with high soft tissue contrast, non-ionization, portability, and cost effectiveness. Few studies investigated clinical application of real-time ultrasound monitoring for abdominal stereotactic body radiation therapy (SBRT). This study aims to demonstrate the feasibility of real-time monitoring of 3D target motion using 4D ultrasound. Methods: An ultrasound probe holding system was designed to allow clinician to freely move and lock ultrasound probe. For phantom study, an abdominal ultrasound phantom was secured on a 2D programmable respiratory motion stage. One side of the stage was elevated than another side to generate 3D motion.more » The motion stage made periodic breath-hold movement. Phantom movement tracked by infrared camera was considered as ground truth. For volunteer study three healthy subjects underwent the same setup for abdominal SBRT with active breath control (ABC). 4D ultrasound B-mode images were acquired for both phantom and volunteers for real-time monitoring. 10 breath-hold cycles were monitored for each experiment. For phantom, the target motion tracked by ultrasound was compared with motion tracked by infrared camera. For healthy volunteers, the reproducibility of ABC breath-hold was evaluated. Results: Volunteer study showed the ultrasound system fitted well to the clinical SBRT setup. The reproducibility for 10 breath-holds is less than 2 mm in three directions for all three volunteers. For phantom study the motion between inspiration and expiration captured by camera (ground truth) is 2.35±0.02 mm, 1.28±0.04 mm, 8.85±0.03 mm in LR, AP, SI directly, respectively. The motion monitored by ultrasound is 2.21±0.07 mm, 1.32±0.12mm, 9.10±0.08mm, respectively. The motion monitoring error in any direction is less than 0.5 mm. Conclusion: The volunteer study proved the clinical feasibility of real-time ultrasound monitoring for abdominal SBRT. The phantom and volunteer ABC studies demonstrated sub-millimeter accuracy of 3D motion movement monitoring.« less

  12. Multimodal intraoperative monitoring: an overview and proposal of methodology based on 1,017 cases

    PubMed Central

    Eggspuehler, Andreas; Muller, Alfred; Dvorak, Jiri

    2007-01-01

    To describe different currently available tests of multimodal intraoperative monitoring (MIOM) used in spine and spinal cord surgery indicating the technical parameters, application and interpretation as an easy understanding systematic overview to help implementation of MIOM and improve communication between neurophysiologists and spine surgeons. This article aims to give an overview and proposal of the different MIOM-techniques as used daily in spine and spinal cord surgery at our institution. Intensive research in neurophysiology over the past decades has lead to a profound understanding of the spinal cord, nerve functions and their intraoperative functional evaluation in anaesthetised patients. At present, spine surgeons and neurophysiologist are faced with 1,883 publications in PubMed on spinal cord monitoring. The value and the limitations of single monitoring methods are well documented. The diagnostic power of the multimodal approach in a larger study population in spine surgery, as measured with sensitivity and specificity, is dealt with elsewhere in this supplement (Sutter et al. in Eur Spine J Suppl, 2007). This paper aims to give a detailed description of the different modalities used in this study. Description of monitoring techniques of the descending and ascending spinal cord and nerve root pathways by motor evoked potentials of the spinal cord and muscles elicited after transcranial electrical motor cortex, spinal cord, cauda equina and nerve root stimulation, continuous EMG, sensory cortical and spinal evoked potentials, as well as direct spinal cord evoked potentials applied on 1,017 patients. The method of MIOM, continuously adapted according to the site, stage of surgery and potential danger to nerve tissues, proved to be applicable with online results, reliable and furthermore teachable. PMID:17653777

  13. Tracheal cuff pressure monitoring in the ICU: a literature review and survey of current practice in Queensland.

    PubMed

    Talekar, C R; Udy, A A; Boots, R J; Lipman, J; Cook, D

    2014-11-01

    The application of tracheal cuff pressure monitoring is likely to vary between institutions. The aim of this study was therefore to review current evidence concerning this intervention in the intensive care unit (ICU) and to appraise regional practice by performing a state-wide survey. Publications for review were identified through searches of PubMed, EMBASE and Cochrane (1977 to 2014). All studies in English relevant to critical care and with complete data were included. Survey questions were developed by small-group consensus. Public and private ICUs across Queensland were contacted, with responses obtained from a representative member of the medical or nursing staff. Existing literature suggests significant variability in tracheal cuff pressure monitoring in the ICU, particularly in the applied technique, frequency of assessment and optimal intra-cuff pressures. Twenty-nine respondents completed the survey, representing 80.5% (29/36) of ICUs in Queensland. Twenty-eight out of twenty-nine respondents reported routinely monitoring tracheal cuff function, primarily employing cuff pressure measurement (26/28). Target cuff pressures varied, with 3/26 respondents aiming for 10 to 20 cmH2O, 10/26 for 21 to 25 cmH2O, and 13/26 for 26 to 30 cmH2O. Fifteen out of twenty-nine reported they had no current guideline or protocol for tracheal cuff management and only 16/29 indicated there was a dedicated area in the clinical record for reporting cuff intervention. Our results indicate that many ICUs across Queensland routinely measure tracheal cuff function, with most utilising pressure monitoring devices. Consistent with existing literature, the optimum cuff pressure remains uncertain. Most, however, considered that this should be a routine part of ICU care.

  14. Designing personal exercise monitoring employing multiple modes of delivery: implications from a qualitative study on heart rate monitoring.

    PubMed

    Segerståhl, Katarina; Oinas-Kukkonen, Harri

    2011-12-01

    Various personal monitoring technologies have been introduced for supporting regular physical activity, which is of critical importance in reducing the risks of several chronic diseases. Recent studies suggest that combining multiple modes of delivery, such as text messages and mobile monitoring devices with web applications, holds potential for effectively supporting physical exercise. Of particular interest is how the functionality and content of these systems should be distributed across the different modes for successful outcomes. The aim of this study was to: (a) investigate how users incorporate a system employing two modes of delivery - a wearable heart rate monitor and a web service - into their training and (b) to analyze benefits and limitations in personal exercise monitoring and how they relate to the different modes in use. A qualitative field study employing diaries and semi-structured interviews was carried out with 30 participants who used a heart rate monitoring system comprising a wearable heart rate monitor, Polar FT60 and a web service, Polar Personal Trainer for a period of 21 days. The data were systematically analyzed to identify specific benefits and limitations associated with the system characteristics and modes as perceived by the end-users. The benefits include supporting exploratory learning, controlling target behavior, rectifying behaviors, motivation and logging support. The limitations are associated with information for validating the system, virtual coaching, task-technology fit, data integrity and privacy concerns. Mobile interfaces enable exploratory learning and controlling of target behaviors in situ, while web services can effectively support users' need for cognition within the early stages of adoption and long-term training with intelligent coaching functionality. This study explains several benefits and limitations in personal exercise monitoring. These can be addressed with crossmedial design, i.e., strategic distribution of functionality and content across modes within the system. Our findings suggest that personal exercise monitoring systems may be improved by more systematically combining mobile and web-based functionality. 2011 Elsevier Ireland Ltd. All rights reserved.

  15. Radar Interferometry for Monitoring the Vibration Characteristics of Buildings and Civil Structures: Recent Case Studies in Spain.

    PubMed

    Luzi, Guido; Crosetto, Michele; Fernández, Enric

    2017-03-24

    The potential of a coherent microwave sensor to monitor the vibration characteristics of civil structures has been investigated in the past decade, and successful case studies have been published by different research teams. This remote sensing technique is based on the interferometric processing of real aperture radar acquisitions. Its capability to estimate, simultaneously and remotely, the displacement of different parts of the investigated structures, with high accuracy and repeatability, is its main advantage with respect to conventional sensors. A considerable amount of literature on this technique is available, including various case studies aimed at testing the ambient vibration of bridges, buildings, and towers. In the last years, this technique has been used in Spain for civil structures monitoring. In this paper, three examples of such case studies are described: the monitoring of the suspended bridge crossing the Ebro River at Amposta, the communications tower of Collserola in Barcelona, and an urban building located in Vilafranca del Penedès, a small town close to Barcelona. This paper summarizes the main outcomes of these case studies, underlining the advantages and limitations of the sensors currently available, and concluding with the possible improvements expected from the next generation of sensors.

  16. A Scoping Review of Economic Evaluations Alongside Randomised Controlled Trials of Home Monitoring in Chronic Disease Management.

    PubMed

    Kidholm, Kristian; Kristensen, Mie Borch Dahl

    2018-04-01

    Many countries have considered telemedicine and home monitoring of patients as a solution to the demographic challenges that health-care systems face. However, reviews of economic evaluations of telemedicine have identified methodological problems in many studies as they do not comply with guidelines. The aim of this study was to examine economic evaluations alongside randomised controlled trials of home monitoring in chronic disease management and hereby to explore the resources included in the programme costs, the types of health-care utilisation that change as a result of home monitoring and discuss the value of economic evaluation alongside randomised controlled trials of home monitoring on the basis of the studies identified. A scoping review of economic evaluations of home monitoring of patients with chronic disease based on randomised controlled trials and including information on the programme costs and the costs of equipment was carried out based on a Medline (PubMed) search. Nine studies met the inclusion criteria. All studies include both costs of equipment and use of staff, but there is large variation in the types of equipment and types of tasks for the staff included in the costs. Equipment costs constituted 16-73% of the total programme costs. In six of the nine studies, home monitoring resulted in a reduction in primary care or emergency contacts. However, in total, home monitoring resulted in increased average costs per patient in six studies and reduced costs in three of the nine studies. The review is limited by the small number of studies found and the restriction to randomised controlled trials, which can be problematic in this area due to lack of blinding of patients and healthcare professionals and the difficulty of implementing organisational changes in hospital departments for the limited period of a trial. Furthermore, our results may be based on assessments of older telemedicine interventions.

  17. Psycho-social aspects of personal health monitoring: a descriptive literature review.

    PubMed

    Muehlan, Holger; Schmidt, Silke

    2013-01-01

    We aimed at providing a short review on already published studies addressing psycho-social issues of personal health monitoring (PHM). Both core questions addressed within this review are: What is the impact of PHM on intended psycho-social and health-related outcomes? And which psycho-social issues affected by or related to PHM have already been investigated? This descriptive review based on a literature search using various databases (Psycinfo, Psyndex, Pubmed, SSCI). Resulting 428 abstracts were coded regarding their psycho-social content. Inspection of results was carried out along the relevance of the papers regarding psycho-social issues. Research in PHM focuses on telemonitoring and smart home applications: Tele-monitoring studies are directed to outcome-related questions, smart home studies to feasibility issues. Despite of technological matters, comparability of both systems in psycho-social issues is lacking. Tele-monitoring has been proven for impact on patient groups with chronic diseases, yet smart home still lacks evidence in health-related and psycho-social matters. Smart home applications have been investigated with respect to attitudes, perceptions and concerns of end-users, telemonitoring regarding acceptance and adherence.

  18. Direct cost of monitoring conventional hemodialysis conducted by nursing professionals.

    PubMed

    Lima, Antônio Fernandes Costa

    2017-04-01

    to analyze the mean direct cost of conventional hemodialysis monitored by nursing professionals in three public teaching and research hospitals in the state of São Paulo, Brazil. this was a quantitative, explorative and descriptive investigation, based on a multiple case study approach. The mean direct cost was calculated by multiplying (clocked) time spent per procedure by the unit cost of direct labor. Values were calculated in Brazilian real (BRL). Hospital C presented the highest mean direct cost (BRL 184.52), 5.23 times greater than the value for Hospital A (BRL 35.29) and 3.91 times greater than Hospital B (BRL 47.22). the costing method used in this study can be reproduced at other dialysis centers to inform strategies aimed at efficient allocation of necessary human resources to successfully monitor conventional hemodialysis.

  19. Main Pipelines Corrosion Monitoring Device

    NASA Astrophysics Data System (ADS)

    Anatoliy, Bazhenov; Galina, Bondareva; Natalia, Grivennaya; Sergey, Malygin; Mikhail, Goryainov

    2017-01-01

    The aim of the article is to substantiate the technical solution for the problem of monitoring corrosion changes in oil and gas pipelines with use (using) of an electromagnetic NDT method. Pipeline wall thinning under operating conditions can lead to perforations and leakage of the product to be transported outside the pipeline. In most cases there is danger for human life and environment. Monitoring of corrosion changes in pipeline inner wall under operating conditions is complicated because pipelines are mainly made of structural steels with conductive and magnetic properties that complicate test signal passage through the entire thickness of the object under study. The technical solution of this problem lies in monitoring of the internal corrosion changes in pipes under operating conditions in order to increase safety of pipelines by automated prediction of achieving the threshold pre-crash values due to corrosion.

  20. German "National Cancer Aid Monitoring" 2015-2019 - study protocol and initial results.

    PubMed

    Schneider, Sven; Görig, Tatiana; Schilling, Laura; Breitbart, Eckhard W; Greinert, Rüdiger; Diehl, Katharina

    2017-09-01

    The National Cancer Aid Monitoring of Tanning Bed Use (NCAM) project is a major German study that aims to observe the most significant risk factors for skin cancer: natural sunlight and artificial UV radiation. NCAM is a nationwide cross-sectional survey that will initially involve four rounds of data collection (so-called waves) between 2015 and 2018. Every year, a representative nationwide sample consisting of 3,000 individuals aged between 14 and 45 years will be surveyed. The cross-sectional survey will be complemented by a panel of n  =  450 current tanning bed users. The initial wave in 2015 shows an overall prevalence of tanning bed use of 29.5 %. Eleven percent of all participants had used a tanning bed within the past twelve months. Determinants of current tanning bed use included younger age, female gender, and full-time/part-time employment. The main motivations for tanning bed use reported were relaxation and increased attractiveness. NCAM is the first study worldwide to monitor skin cancer risk factors at one-year intervals using a large, nationally representative sample. Initial results indicate that, despite WHO warnings, millions of Germans use tanning beds, and that many of these users are adolescents despite legal restrictions aimed at preventing minors from using tanning beds. © 2017 Deutsche Dermatologische Gesellschaft (DDG). Published by John Wiley & Sons Ltd.

  1. The Impact of AUC-Based Monitoring on Pharmacist-Directed Vancomycin Dose Adjustments in Complicated Methicillin-Resistant Staphylococcus aureus Infection.

    PubMed

    Stoessel, Andrew M; Hale, Cory M; Seabury, Robert W; Miller, Christopher D; Steele, Jeffrey M

    2018-01-01

    This study aimed to assess the impact of area under the curve (AUC)-based vancomycin monitoring on pharmacist-initiated dose adjustments after transitioning from a trough-only to an AUC-based monitoring method at our institution. A retrospective cohort study of patients treated with vancomycin for complicated methicillin-resistant Staphylococcus aureus (MRSA) infection between November 2013 and December 2016 was conducted. The frequency of pharmacist-initiated dose adjustments was assessed for patients monitored via trough-only and AUC-based approaches for trough ranges: 10 to 14.9 mg/L and 15 to 20 mg/L. Fifty patients were included: 36 in the trough-based monitoring and 14 in the AUC-based-monitoring group. The vancomycin dose was increased in 71.4% of patients when troughs were 10 to 14.9 mg/L when a trough-only approach was used and in only 25% of patients when using AUC estimation ( P = .048). In the AUC group, the dose was increased only when AUC/minimum inhibitory concentration (MIC) <400; unchanged regimens had an estimated AUC/MIC ≥400. The AUC-based monitoring did not significantly increase the frequency of dose reductions when trough concentrations were 15 to 20 mg/L (AUC: 33.3% vs trough: 4.6%; P = .107). The AUC-based monitoring resulted in fewer patients with dose adjustments when trough levels were 10 to 14.9 mg/L. The AUC-based monitoring has the potential to reduce unnecessary vancomycin exposure and warrants further investigation.

  2. Tracking Concept Development through Semiotic Evolution

    ERIC Educational Resources Information Center

    Ronen, Ilana

    2015-01-01

    A qualitative research focused on a case study aiming to monitor emergent knowledge in a discourse group by tracking the development of the concept "goal." The analysis, based on "Semiotic Evolution" methodology facilitates the description of interactions between personal perceptions in the group discourse, illustrating the…

  3. Investigation of the fluidity of biological fluids with a PDDTBN spin probe

    NASA Astrophysics Data System (ADS)

    Severcan, Feride; Acar, Berrin; Gökalp, Saadet

    1997-06-01

    The aim of this study is to ascertain whether the electron spin resonance technique using perdeutero-di- t-butyl nitroxide (PDDTBN) as a spin probe is able to monitor relative fluidity changes occurring in body fluids, such as blood and parotid saliva, according to different physiological conditions. The present study reveals that the spin probe PDDTBN is able to monitor the fluidity changes in parotid saliva related to habitual smoking, and in whole blood related to the estradiol level. The rotational correlation time of the spin probe and the local viscosity values of the parotid saliva and blood have been reported.

  4. The Epidemiology of Epilepsy and Traumatic Brain Injury: Severity, Mechanism, and Outcomes

    DTIC Science & Technology

    2017-10-01

    INVESTIGATOR: Mary Jo Pugh, PhD RN CONTRACTING ORGANIZATION: Foundation for Advancing Veterans Health Research San Antonio, TX 78229 REPORT DATE...for Advancing Veterans Health Research 7400 Merton Minter Blvd San Antonio, TX 78230-4404 9. SPONSORING / MONITORING AGENCY NAME(S) AND ADDRESS...Veterans Health Research Award Amount: $2,199,189 Study Aims •Aim 1: Identify a cohort of Post-9/11 Veterans who received VA care during at least two

  5. Monitoring of recurrent and superior laryngeal nerve function using an Airwayscope™ during thyroid surgery.

    PubMed

    Ijichi, Kei; Sasano, Hiroshi; Harima, Megumi; Murakami, Shingo

    2017-10-01

    In thyroid surgery, intraoperative identification and preservation of the recurrent laryngeal nerve (RLN) and superior laryngeal nerve external branch (SLNEB) are crucial. Several reports have proposed that electromyography (EMG) monitoring is an acceptable adjunct for identification and preservation of the RLN. However, a limited number of hospitals have access to an EMG monitoring system. Therefore, the development of another viable monitoring method is required. The aim of the present study was to design a new RLN and SLNEB monitoring method combining an Airwayscope™ (AWS) and a facial nerve stimulator. The facial nerve-stimulating electrode stimulates the RLN or SLNEB, so that the movement of the vocal cord may be observed with an AWS. This monitoring method was performed on 10 patients with a thyroid tumor. In all the cases, RLN and SLNEB were identified and vocal cord function was preserved. All the patients exhibited normal vocal cord function following surgery. Thus, the new RLN and SLNEB monitoring method using an AWS and a facial nerve stimulator is useful in thyroid surgery, and this method may be used as a reliable and available alternative to EMG monitoring to ensure the normal function of the vocal cord.

  6. Geostatistical screening of flood events in the groundwater levels of the diverted inner delta of the Danube River: implications for river bed clogging

    NASA Astrophysics Data System (ADS)

    Trásy, Balázs; Garamhegyi, Tamás; Laczkó-Dobos, Péter; Kovács, József; Hatvani, István Gábor

    2018-04-01

    The efficient operation of shallow groundwater (SGW) monitoring networks is crucial to water supply, in-land water protection, agriculture and nature conservation. In the present study, the spatial representativity of such a monitoring network in an area that has been thoroughly impacted by anthropogenic activity (river diversion/damming) is assessed, namely the Szigetköz adjacent to the River Danube. The main aims were to assess the spatial representativity of the SGW monitoring network in different discharge scenarios, and investigate the directional characteristics of this representativity, i.e. establish whether geostatistical anisotropy is present, and investigate how this changes with flooding. After the subtraction of a spatial trend from the time series of 85 shallow groundwater monitoring wells tracking flood events from 2006, 2009 and 2013, variography was conducted on the residuals, and the degree of anisotropy was assessed to explore the spatial autocorrelation structure of the network. Since the raw data proved to be insufficient, an interpolated grid was derived, and the final results were scaled to be representative of the original raw data. It was found that during floods the main direction of the spatial variance of the shallow groundwater monitoring wells alters, from perpendicular to the river to parallel with it for over a period of about two week. However, witht the passing of the flood, this returns to its original orientation in 2 months. It is likely that this process is related first to the fast removal of clogged riverbed strata by the flood, then to their slower replacement. In addition, the study highlights the importance of assessing the direction of the spatial autocorrelation structure of shallow groundwater monitoring networks, especially if the aim is to derive interpolated maps for the further investigation or modeling of flow.

  7. Multi-scale ecosystem monitoring: an application of scaling data to answer multiple ecological questions

    USDA-ARS?s Scientific Manuscript database

    Background/Question/Methods Standardized monitoring data collection efforts using a probabilistic sample design, such as in the Bureau of Land Management’s (BLM) Assessment, Inventory, and Monitoring (AIM) Strategy, provide a core suite of ecological indicators, maximize data collection efficiency,...

  8. Optimizing Antibiotic Use in Nursing Homes Through Antibiotic Stewardship.

    PubMed

    Sloane, Philip D; Huslage, Kirk; Kistler, Christine E; Zimmerman, Sheryl

    2016-01-01

    Antibiotic stewardship is becoming a requirement for nursing homes. Programs should be interdisciplinary and multifaceted; should have support from nursing home administrators; and should aim to promote antibiotics only when needed, not just in case. Recommended components include use of evidence-based guidelines; ongoing monitoring of antibiotic prescriptions, cultures, and study results; monitoring of health outcomes; use of nursing home-specific antibiograms; regular reporting and feedback to medical providers and nurses; and education of residents and families. ©2016 by the North Carolina Institute of Medicine and The Duke Endowment. All rights reserved.

  9. Occlusal overload investigations by noninvasive technology: fluorescence microscopy and en-face optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Marcauteanu, Corina; Negrutiu, Meda; Sinescu, Cosmin; Demjan, Enikö; Hughes, Michael; Bradu, Adrian; Dobre, George; Podoleanu, Adrian G.

    2009-07-01

    The aim of this study is the early detection and monitoring of occlusal overload in bruxing patients. En-Face Optical coherence tomography (eF-OCT) and fluorescence microscopy (FM) were used for the imaging of several anterior teeth extracted from patients with light active bruxism. We found a characteristic pattern of enamel cracks, that reached the tooth surface. We concluded that the combination of the en-Face OCT and FM is a promising non-invasive alternative technique for reliable monitoring of occlusal overload.

  10. Cancer incidence and incidence rates in Japan in 2008: a study of 25 population-based cancer registries for the Monitoring of Cancer Incidence in Japan (MCIJ) project.

    PubMed

    Matsuda, Ayako; Matsuda, Tomohiro; Shibata, Akiko; Katanoda, Kota; Sobue, Tomotaka; Nishimoto, Hiroshi

    2014-04-01

    The Japan Cancer Surveillance Research Group aimed to estimate the cancer incidence in Japan in 2008 based on data collected from 25 of 34 population-based cancer registries, as part of the Monitoring of Cancer Incidence in Japan project. The incidence in Japan for 2008 was estimated to be 749 767 (C00-C96). Stomach cancer and breast cancer were the leading types of cancer in males and females, respectively.

  11. An overview of Brazilian experience on measuring runoff and soil loss rates

    USDA-ARS?s Scientific Manuscript database

    Efforts have been made to determine soil erosion rates using runoff plots, mainly in the last century. In Brazil, the first experimental studies in plot-scale monitoring sites started in the 1940s. Thus, we aim to show an overview of plot-scale studies under natural rainfall over the country. We rev...

  12. Judgements about Knowledge: Searching for Factors that Influence Their Validity

    ERIC Educational Resources Information Center

    Mengelkamp, Christoph; Bannert, Maria

    2009-01-01

    Introduction: Research in the field of metacomprehension often uses the accuracy of judgements of own knowledge as a measure of monitoring which is a central component of metacognition. One aim of this study is to investigate if the accuracy above chance usually found in studies using traditional texts can be replicated with hypermedia. More…

  13. Trends in Adolescent Substance Use: The Mokotow Study 1988-2004

    ERIC Educational Resources Information Center

    Ostaszewski, Krzysztof; Pisarska, Agnieszka

    2008-01-01

    This study, conducted every 4 years since 1984, is aimed at monitoring alcohol, tobacco, tranquillizers and illegal drug-use trends among 15-year-olds from Warsaw. The self-report data are taken from a representative sample of students attending schools in three districts of Warsaw (sample size ranged from 1461 to 3918 in the different study…

  14. The Assessment of Halogenating Stress in Population by the Environmental and Health Monitoring

    ERIC Educational Resources Information Center

    Namazbaeva, Zulkiya I.; Dosybaeva, Gulzhan N.; Sabirov, Zhanbol B.; Bazelyuk, Ludmila T.; Asanov, Galiya K.; Baidaulet, Imanali O.

    2016-01-01

    This study aimed to find out the dependence of myeloperoxidase content in patients living in the environmentally unfriendly region of Kazakhstan (Taraz), on the PCBs content in the air. During this study, 324 patients were examined to solve the clinical problem. The content of myeloperoxidase fluctuated significantly depending on the age of the…

  15. Supervised versus unsupervised technology-based levodopa monitoring in Parkinson's disease: an intrasubject comparison.

    PubMed

    Lopane, Giovanna; Mellone, Sabato; Corzani, Mattia; Chiari, Lorenzo; Cortelli, Pietro; Calandra-Buonaura, Giovanna; Contin, Manuela

    2018-06-01

    We aimed to assess the intrasubject reproducibility of a technology-based levodopa (LD) therapeutic monitoring protocol administered in supervised versus unsupervised conditions in patients with Parkinson's disease (PD). The study design was pilot, intrasubject, single center, open and prospective. Twenty patients were recruited. Patients performed a standardized monitoring protocol instrumented by an ad hoc embedded platform after their usual first morning LD dose in two different randomized ambulatory sessions: one under a physician's supervision, the other self-administered. The protocol is made up of serial motor and non-motor tests, including alternate finger tapping, Timed Up and Go test, and measurement of blood pressure. Primary motor outcomes included comparisons of intrasubject LD subacute motor response patterns over the 3-h test in the two experimental conditions. Secondary outcomes were the number of intrasession serial test repetitions due to technical or handling errors and patients' satisfaction with the unsupervised LD monitoring protocol. Intrasubject LD motor response patterns were concordant between the two study sessions in all patients but one. Platform handling problems averaged 4% of total planned serial tests for both sessions. Ninety-five percent of patients were satisfied with the self-administered LD monitoring protocol. To our knowledge, this study is the first to explore the potential of unsupervised technology-based objective motor and non-motor tasks to monitor subacute LD dosing effects in PD patients. The results are promising for future telemedicine applications.

  16. Square2 - A Web Application for Data Monitoring in Epidemiological and Clinical Studies

    PubMed

    Schmidt, Carsten Oliver; Krabbe, Christine; Schössow, Janka; Albers, Martin; Radke, Dörte; Henke, Jörg

    2017-01-01

    Valid scientific inferences from epidemiological and clinical studies require high data quality. Data generating departments therefore aim to detect data irregularities as early as possible in order to guide quality management processes. In addition, after the completion of data collections the obtained data quality must be evaluated. This can be challenging in complex studies due to a wide scope of examinations, numerous study variables, multiple examiners, devices, and examination centers. This paper describes a Java EE web application used to monitor and evaluate data quality in institutions with complex and multiple studies, named Square 2 . It uses the Java libraries Apache MyFaces 2, extended by BootsFaces for layout and style. RServe and REngine manage calls to R server processes. All study data and metadata are stored in PostgreSQL. R is the statistics backend and LaTeX is used for the generation of print ready PDF reports. A GUI manages the entire workflow. Square 2 covers all steps in the data monitoring workflow, including the setup of studies and their structure, the handling of metadata for data monitoring purposes, selection of variables, upload of data, statistical analyses, and the generation as well as inspection of quality reports. To take into account data protection issues, Square 2 comprises an extensive user rights and roles concept.

  17. Can a smart chair improve the sitting behavior of office workers?

    PubMed

    Roossien, C C; Stegenga, J; Hodselmans, A P; Spook, S M; Koolhaas, W; Brouwer, S; Verkerke, G J; Reneman, M F

    2017-11-01

    Prolonged sitting can cause health problems and musculoskeletal discomfort. There is a need for objective and non-obstructive means of measuring sitting behavior. A 'smart' office chair can monitor sitting behavior and provide tactile feedback, aiming to improve sitting behavior. This study aimed to investigate the effect of the feedback signal on sitting behavior and musculoskeletal discomfort. In a 12-week prospective cohort study (ABCB design) among office workers (n = 45) was measured sitting duration and posture, feedback signals and musculoskeletal discomfort. Between the study phases, small changes were observed in mean sitting duration, posture and discomfort. After turning off the feedback signal, a slight increase in sitting duration was observed (10 min, p = 0.04), a slight decrease in optimally supported posture (2.8%, p < 0.01), and musculoskeletal discomfort (0.8, p < 0.01) was observed. We conclude that the 'smart' chair is able to monitor the sitting behavior, the feedback signal, however, led to small or insignificant changes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Improved Marine Waters Monitoring

    NASA Astrophysics Data System (ADS)

    Palazov, Atanas; Yakushev, Evgeniy; Milkova, Tanya; Slabakova, Violeta; Hristova, Ognyana

    2017-04-01

    IMAMO - Improved Marine Waters Monitoring is a project under the Programme BG02: Improved monitoring of marine waters, managed by Bulgarian Ministry of environment and waters and co-financed by the Financial Mechanism of the European Economic Area (EEA FM) 2009 - 2014. Project Beneficiary is the Institute of oceanology - Bulgarian Academy of Sciences with two partners: Norwegian Institute for Water Research and Bulgarian Black Sea Basin Directorate. The Project aims to improve the monitoring capacity and expertise of the organizations responsible for marine waters monitoring in Bulgaria to meet the requirements of EU and national legislation. The main outcomes are to fill the gaps in information from the Initial assessment of the marine environment and to collect data to assess the current ecological status of marine waters including information as a base for revision of ecological targets established by the monitoring programme prepared in 2014 under Art. 11 of MSFD. Project activities are targeted to ensure data for Descriptors 5, 8 and 9. IMAMO aims to increase the institutional capacity of the Bulgarian partners related to the monitoring and assessment of the Black Sea environment. The main outputs are: establishment of real time monitoring and set up of accredited laboratory facilities for marine waters and sediments chemical analysis to ensure the ability of Bulgarian partners to monitor progress of subsequent measures undertaken.

  19. Emerging ecological datasets with application for modeling North American dust emissions

    USDA-ARS?s Scientific Manuscript database

    In 2011 the US Bureau of Land Management (BLM) established the Assessment, Inventory and Monitoring (AIM) program to monitor the condition of BLM land and to provide data to support evidence-based management of multi-use public lands. The monitoring program shares core data collection methods with t...

  20. Development of Students' Personal Professional Theories in Senior Secondary Vocational Education

    ERIC Educational Resources Information Center

    Schaap, H.; Van der Schaaf, M. F.; de Bruijn, E.

    2011-01-01

    Students in competence-based senior secondary vocational education are expected to actively construct personal knowledge during school-based learning and workplace learning. This study introduces the construct "personal professional theory" (PPT) to monitor and analyse students' personal knowledge development. It aims to investigate the…

  1. A Systematic Review of Economic Evaluations of Pacemaker Telemonitoring Systems.

    PubMed

    López-Villegas, Antonio; Catalán-Matamoros, Daniel; Martín-Saborido, Carlos; Villegas-Tripiana, Irene; Robles-Musso, Emilio

    2016-02-01

    Over the last decade, telemedicine applied to pacemaker monitoring has undergone extraordinary growth. It is not known if telemonitoring is more or less efficient than conventional monitoring. The aim of this study was to carry out a systematic review analyzing the available evidence on resource use and health outcomes in both follow-up modalities. We searched 11 databases and included studies published up until November 2014. The inclusion criteria were: a) experimental or observational design; b) studies based on complete economic evaluations; c) patients with pacemakers, and d) telemonitoring compared with conventional hospital monitoring. Seven studies met the inclusion criteria, providing information on 2852 patients, with a mean age of 81 years. The main indication for device implantation was atrioventricular block. With telemonitoring, cardiovascular events were detected and treated 2 months earlier than with conventional monitoring, thus reducing length of hospital stay by 34% and reducing routine and emergency hospital visits as well. There were no significant intergroup differences in perceived quality of life or number of adverse events. The cost of telemonitoring was 60% lower than that of conventional hospital monitoring. Compared with conventional monitoring, cardiovascular events were detected earlier and the number or hospitalizations and hospital visits was reduced with pacemaker telemonitoring. In addition, the costs associated with follow-up were lower with telemonitoring. Copyright © 2015 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  2. Is the soil quality monitoring an effective tool in consumers' protection of agricultural crops from cadmium soil contamination?-a case of the Silesia region (Poland).

    PubMed

    Piekut, Agata; Baranowska, Renata; Marchwińska-Wyrwał, Ewa; Ćwieląg-Drabek, Małgorzata; Hajok, Ilona; Dziubanek, Grzegorz; Grochowska-Niedworok, Elżbieta

    2017-12-16

    The monitoring of soil quality should be a control tool used to reduce the adverse health effects arising from exposure to toxic chemicals in soil through cultivated crop absorption. The aim of the study was to evaluate the effectiveness of the monitoring and control system of soil quality in Poland, in terms of consumer safety, for agricultural plants cultivated in areas with known serious cadmium contamination, such as Silesia Province. To achieve the objective, the contents of cadmium in soils and vegetables in the Silesia administrative area were examined. The obtained results were compared with the results of soil contamination from the quality monitoring of arable soil in Poland. The studies show a significant exceedance of the permissible values of cadmium in soil samples and the vegetables cultivated on that soil. The threat to consumer health is a valid concern, although this threat was not indicated by the results of the national monitoring of soil quality. The results indicated an unequal distribution of risk to consumers resulting from contaminated soil. Moreover, the monitoring systems should be designed at the local or regional scale to guarantee the safety of consumers of edible plants cultivated in the areas contaminated with cadmium.

  3. Is it me? Verbal self-monitoring neural network and clinical insight in schizophrenia

    PubMed Central

    Sapara, Adegboyega; ffytche, Dominic H.; Cooke, Michael A.; Williams, Steven C.R.; Kumari, Veena

    2015-01-01

    Self-monitoring, defined as the ability to distinguish between self-generated stimuli from other-generated ones, is known to be impaired in schizophrenia. This impairment has been theorised as the basis for many of the core psychotic symptoms, in particular, poor clinical insight. This study aimed to investigate verbal self-monitoring related neural substrates of preserved and poor clinical insight in schizophrenia. It involved 40 stable schizophrenia outpatients, 20 with preserved and 20 with poor insight, and 20 healthy participants. All participants underwent functional magnetic resonance imaging with brain coverage covering key areas in the self-monitoring network during a verbal self-monitoring task. Healthy participants showed higher performance accuracy and greater thalamic activity than both preserved and poor insight patient groups. Preserved insight patients showed higher activity in the putamen extending into the caudate, insula and inferior frontal gyrus, compared to poor insight patients, and in the anterior cingulate and medial frontal gyrus, compared to healthy participants. Poor insight patients did not show greater activity in any brain area compared to preserved insight patients or healthy participants. Future studies may pursue therapeutic avenues, such as meta-cognitive therapies to promote self-monitoring or targeted stimulation of relevant brain areas, as means of enhancing insight in schizophrenia. PMID:26549744

  4. Liquid volume monitoring based on ultrasonic sensor and Arduino microcontroller

    NASA Astrophysics Data System (ADS)

    Husni, M.; Siahaan, D. O.; Ciptaningtyas, H. T.; Studiawan, H.; Aliarham, Y. P.

    2016-04-01

    Incident of oil leakage and theft in oil tank often happens. To prevent it, the liquid volume insides the tank needs to be monitored continuously. Aim of the study is to calculate the liquid volume inside oil tank on any road condition and send the volume data and location data to the user. This research use some ultrasonic sensors (to monitor the fluid height), Bluetooth modules (to sent data from the sensors to the Arduino microcontroller), Arduino Microcontroller (to calculate the liquid volume), and also GPS/GPRS/GSM Shield module (to get location of vehicle and sent the data to the Server). The experimental results show that the accuracy rate of monitoring liquid volume inside tanker while the vehicle is in the flat road is 99.33% and the one while the vehicle is in the road with elevation angle is 84%. Thus, this system can be used to monitor the tanker position and the liquid volume in any road position continuously via web application to prevent illegal theft.

  5. An Efficient Wireless Sensor Network for Industrial Monitoring and Control.

    PubMed

    Aponte-Luis, Juan; Gómez-Galán, Juan Antonio; Gómez-Bravo, Fernando; Sánchez-Raya, Manuel; Alcina-Espigado, Javier; Teixido-Rovira, Pedro Miguel

    2018-01-10

    This paper presents the design of a wireless sensor network particularly designed for remote monitoring and control of industrial parameters. The article describes the network components, protocol and sensor deployment, aimed to accomplish industrial constraint and to assure reliability and low power consumption. A particular case of study is presented. The system consists of a base station, gas sensing nodes, a tree-based routing scheme for the wireless sensor nodes and a real-time monitoring application that operates from a remote computer and a mobile phone. The system assures that the industrial safety quality and the measurement and monitoring system achieves an efficient industrial monitoring operations. The robustness of the developed system and the security in the communications have been guaranteed both in hardware and software level. The system is flexible and can be adapted to different environments. The testing of the system confirms the feasibility of the proposed implementation and validates the functional requirements of the developed devices, the networking solution and the power consumption management.

  6. An Efficient Wireless Sensor Network for Industrial Monitoring and Control

    PubMed Central

    Aponte-Luis, Juan; Gómez-Bravo, Fernando; Sánchez-Raya, Manuel; Alcina-Espigado, Javier; Teixido-Rovira, Pedro Miguel

    2018-01-01

    This paper presents the design of a wireless sensor network particularly designed for remote monitoring and control of industrial parameters. The article describes the network components, protocol and sensor deployment, aimed to accomplish industrial constraint and to assure reliability and low power consumption. A particular case of study is presented. The system consists of a base station, gas sensing nodes, a tree-based routing scheme for the wireless sensor nodes and a real-time monitoring application that operates from a remote computer and a mobile phone. The system assures that the industrial safety quality and the measurement and monitoring system achieves an efficient industrial monitoring operations. The robustness of the developed system and the security in the communications have been guaranteed both in hardware and software level. The system is flexible and can be adapted to different environments. The testing of the system confirms the feasibility of the proposed implementation and validates the functional requirements of the developed devices, the networking solution and the power consumption management. PMID:29320466

  7. [Designing and implementation of a web-based quality monitoring system for plasma glucose measurement in multicenter population study].

    PubMed

    Liu, Yong; Wang, Limin; Pang, Richard; Mo, Nanxun; Hu, Yan; Deng, Qian; Hu, Zhaohui

    2015-05-01

    The aim of this paper is to describe the designing and implementation of a web-based plasma glucose measurement quality monitoring system to assess the analytical quality of plasma glucose measurements in multicenter population study and provide evidence for the future studies. In the chronic non-communicable disease and related factor surveillance in China, a web based quality monitoring system for plasma glucose measurement was established to conduct evaluation on plasma glucose monitoring quality and effectiveness in 302 surveillance centers, including quality control data entry, transmission and feedback. The majority of the surveillance centers met the quality requirements and passed the evaluation of reproducibility and precision of plasma glucose measurement, only a few centers required intensive training and re-assessment. In order to ensure the completeness and reliability of plasma glucose measurement in the surveillance centers, the establishment of web-based plasma glucose measurement quality control system can facilitate the identification of the qualified surveillance centers and evaluation of plasma glucose measurement quality in different regions. Communication and training are important in ensuring plasma glucose measurement quality. It is necessary to further improve this web-based plasma glucose measurement quality monitoring system in the future to reduce the method specific plasma glucose measurement bias.

  8. Mandated monitoring of post-project impacts in the Czech EIA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Branis, Martin; Christopoulos, Stamatios

    2005-04-15

    Altogether, 801 documents of consent (50% of all) issued under the EIA Act No. 244/1992 by the competent authorities in the Czech Republic between 1993 and 2001 were studied. The aim of the analysis was to find and characterize conditions prescribing to the developer to perform ex-ante and ex-post monitoring of potential impacts of projects submitted for approval. It was found that each of the studied documents (standpoints) contained on average three to four conditions prescribing to collect data on various environmental factors during the preparation, implementation and/or operation phase of the development in question. The number of monitoring conditionsmore » contained in the standpoints issued by the Ministry of Environment as well as by the District Offices increased during the period studied from about two to five per project indicating a growing interest in and/or need to obtaining such data. Even though there is a good legal background for collecting monitoring data from implementation and operation phase of new developments, the Czech EIA Act (similarly as EIA acts in other countries) does not provide any practical background for this activity. Without relevant institutional, personal and financial support the possibility to impose post-project monitoring to the developer remains rather a challenge to, not advantage of the Czech EIA Act.« less

  9. KSC-07pd0706

    NASA Image and Video Library

    2007-03-16

    VANDENBERG AIR FORCE BASE, CALIF. -- In a clean-room environment at North Vandenberg Air Force Base, a technician monitors the AIM spacecraft after illumination testing on the spacecraft's solar array panels. The AIM spacecraft will fly three instruments designed to study those clouds located at the edge of space, 50 miles above the Earth's surface in the coldest part of the planet's atmosphere. The mission's primary goal is to explain why these clouds form and what has caused them to become brighter and more numerous and appear at lower latitudes in recent years. AIM's results will provide the basis for the study of long-term variability in the mesospheric climate and its relationship to global climate change. AIM is scheduled to be mated to the Pegasus XL during the second week of April, after which final inspections will be conducted. Launch is scheduled for April 25.

  10. A Context-Aware Indoor Air Quality System for Sudden Infant Death Syndrome Prevention

    PubMed Central

    De Paz, Juan F.; Barriuso, Alberto L.

    2018-01-01

    Context-aware monitoring systems designed for e-Health solutions and ambient assisted living (AAL) play an important role in today’s personalized health-care services. The majority of these systems are intended for the monitoring of patients’ vital signs by means of bio-sensors. At present, there are very few systems that monitor environmental conditions and air quality in the homes of users. A home’s environmental conditions can have a significant influence on the state of the health of its residents. Monitoring the environment is the key to preventing possible diseases caused by conditions that do not favor health. This paper presents a context-aware system that monitors air quality to prevent a specific health problem at home. The aim of this system is to reduce the incidence of the Sudden Infant Death Syndrome, which is triggered mainly by environmental factors. In the conducted case study, the system monitored the state of the neonate and the quality of air while it was asleep. The designed proposal is characterized by its low cost and non-intrusive nature. The results are promising. PMID:29498653

  11. A Context-Aware Indoor Air Quality System for Sudden Infant Death Syndrome Prevention.

    PubMed

    De La Iglesia, Daniel H; De Paz, Juan F; Villarrubia González, Gabriel; Barriuso, Alberto L; Bajo, Javier

    2018-03-02

    Context-aware monitoring systems designed for e-Health solutions and ambient assisted living (AAL) play an important role in today's personalized health-care services. The majority of these systems are intended for the monitoring of patients' vital signs by means of bio-sensors. At present, there are very few systems that monitor environmental conditions and air quality in the homes of users. A home's environmental conditions can have a significant influence on the state of the health of its residents. Monitoring the environment is the key to preventing possible diseases caused by conditions that do not favor health. This paper presents a context-aware system that monitors air quality to prevent a specific health problem at home. The aim of this system is to reduce the incidence of the Sudden Infant Death Syndrome, which is triggered mainly by environmental factors. In the conducted case study, the system monitored the state of the neonate and the quality of air while it was asleep. The designed proposal is characterized by its low cost and non-intrusive nature. The results are promising.

  12. Diagnostic and therapeutic yield of a patient-controlled portable EEG device with dry electrodes for home-monitoring neurological outpatients-rationale and protocol of the HOMEONE pilot study.

    PubMed

    Neumann, Thomas; Baum, Anne Katrin; Baum, Ulrike; Deike, Renate; Feistner, Helmut; Hinrichs, Hermann; Stokes, Joseph; Robra, Bernt-Peter

    2018-01-01

    The HOME ONE study is part of the larger HOME project, which aims to provide evidence of diagnostic and therapeutic yield ("change of management") of a patient-controlled portable EEG device with dry electrodes for the purposes of EEG home-monitoring neurological outpatients. The HOME ONE study is the first step in the process of investigating whether outpatient EEG home-monitoring changes the diagnosis and treatment of patients in comparison to conventional EEG ("change of management"). Both EEG devices (conventional and portable) will be systematically compared via a two-phase intra-individual assessment.In the first phase (pilot study phase), both EEG devices will be used within neurologist practices (all other things being equal). This pilot study (involving 130 patients) will evaluate the technical usability and efficacy of the new portable dry electrode EEG recorder in comparison to conventional EEG devices. Judgements will be based on technical assessments and EEG record examinations of private practitioners and two experienced neurologists (percent of concordant readings and kappa values).The second phase (feasibility study phase) aims to assess patients' acceptability and feasibility of the EEG home-monitoring and will provide insights into the extent diagnostic and therapeutic yields can be expected.For this purpose, a conventional EEG will be recorded in neurologist practices. Thereafter, the practice staff will instruct the patients on how the portable EEG device functions. The patients will subsequently use the devices in their home environment.The evaluation will compare the before and after documented diagnostic findings and the therapeutic consequences of the private practitioners with those of two experienced neurologists. To the best of our knowledge, this will be the first study of its kind to examine new approaches to diagnosing unclear consciousness disorders or other disorders of the CNS or the cardiovascular system through the use of a patient-controlled portable EEG device with dry electrodes for the purpose of home-monitoring neurological outpatients. If the two phases of the HOME ONE study provide sufficient evidence of diagnostic and therapeutic yields, this would justify (indication-specific) full-scale randomized controlled trials or observational studies. DRKS DRKS00012685. Registered 9 August 2017, retrospectively registered.

  13. Validation of the SEJOY BP-1307 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Lei, Lei; Chen, Yi; Chen, Qi; Li, Yan; Wang, Ji-Guang

    2017-12-01

    The present study aimed to evaluate the accuracy of the automated oscillometric upper-arm blood pressure monitor SEJOY BP-1307 (also called JOYTECH DBP-1307) for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese individuals (13 women, 45.1 years of mean age) using a mercury sphygmomanometer (two observers) and the SEJOY BP-1307 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The average±SD of the device-observer differences was 0.2±4.1 and -1.7±4.7 mmHg for systolic and diastolic blood pressure, respectively. The SEJOY BP-1307 device achieved the criteria in both part 1 and part 2 of the validation study. The SEJOY upper-arm blood pressure monitor BP-1307 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  14. Pollution monitoring using networks of honey bees

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bromenshenk, J.J.; Dewart, M.L.; Thomas, J.M.

    1983-08-01

    Each year thousands of chemicals in large quantities are introduced into the global environment and the need for effective methods of monitoring these substances has steadily increased. Most monitoring programs rely upon instrumentation to measure specific contaminants in air, water, or soil. However, it has become apparent that humans and their environment are exposed to complex mixtures of chemicals rather than single entities. As our ability to detect ever smaller quantities of pollutants has increased, the biological significance of these findings has become more uncertain. Also, it is clear that monitoring efforts should shift from short-term studies of easily identifiablemore » sources in localized areas to long-term studies of multiple sources over widespread regions. Our investigations aim at providing better tools to meet these exigencies. Honey bees are discussed as an effective, long-term, self-sustaining system for monitoring environmental impacts. Our results indicate that the use of regional, and possibly national or international, capability can be realized with the aid of beekeepers in obtaining samples and conducting measurements. This approach has the added advantage of public involvement in environmental problem solving and protection of human health and environmental quality.« less

  15. [Monitoring of environmental pollution in Armenia and certain issues on reproductive health and cytogenetic status of organism].

    PubMed

    Tadevosian, N S; Muradian, S A; Tadevosian, A E; Khachatrian, B G; Dzhandzhapanian, A N; Parsadanian, G G; Pogosian, S B; Gevorkian, N B; Guloian, A A

    2012-01-01

    Investigations aimed at the study on the state of environment from the point of pollution by organochlorine pesticides and their metabolites (HCH, DDT, DDE and DDD), as well as on possible unfavorable impact due to carriage of mentioned persistent organic pollutants (POPs) towards reproductive health and cytogenetic status of organism were done. In parallel, monitoring of possible mutagenic components of the environment was also conducted. As to obtained data, residues of organochlorine pesticides are continually determined with high frequency both in environmental media, agricultural foodstuffs and biomedia of rural population of observed region (Aragatsotn marz, Armenia). No changes in mutagenic background were registered. The represented results of the study make fragment of complex social-hygienic, monitoring investigations on environmental quality that would further serve as a platform for working out the recommendations on reduction of environmental pollution and improvement of health protection issues in Armenia.

  16. Perceived class climate and school-aged children's life satisfaction: The role of the learning environment in classrooms.

    PubMed

    Rathmann, Katharina; Herke, Max G; Hurrelmann, Klaus; Richter, Matthias

    2018-01-01

    The aim of this study is to examine the impact of class-level class climate on school-aged children's life satisfaction. Data was derived from the German National Educational Panel Study (NEPS) using sixth grade school-aged children (n = 4,764, 483 classes). Class climate includes indicators of teachers' care and monitoring, demands, interaction, autonomy, as well as school-aged children's attitudes towards schoolwork at the class- and individual-level. Results showed that individual perceived class climate in terms of teachers' care and monitoring and autonomy was positively related to life satisfaction, whereas school-related demands were related to lower life satisfaction. Besides teachers' care and monitoring at class-level, indicators of class climate were not associated with school-aged children's life satisfaction, while the individual perceived class climate is more important for life satisfaction.

  17. Perceived class climate and school-aged children's life satisfaction: The role of the learning environment in classrooms

    PubMed Central

    Herke, Max G.; Hurrelmann, Klaus; Richter, Matthias

    2018-01-01

    The aim of this study is to examine the impact of class-level class climate on school-aged children’s life satisfaction. Data was derived from the German National Educational Panel Study (NEPS) using sixth grade school-aged children (n = 4,764, 483 classes). Class climate includes indicators of teachers' care and monitoring, demands, interaction, autonomy, as well as school-aged children's attitudes towards schoolwork at the class- and individual-level. Results showed that individual perceived class climate in terms of teachers' care and monitoring and autonomy was positively related to life satisfaction, whereas school-related demands were related to lower life satisfaction. Besides teachers' care and monitoring at class-level, indicators of class climate were not associated with school-aged children’s life satisfaction, while the individual perceived class climate is more important for life satisfaction. PMID:29420540

  18. A remote data access architecture for home-monitoring health-care applications.

    PubMed

    Lin, Chao-Hung; Young, Shuenn-Tsong; Kuo, Te-Son

    2007-03-01

    With the aging of the population and the increasing patient preference for receiving care in their own homes, remote home care is one of the fastest growing areas of health care in Taiwan and many other countries. Many remote home-monitoring applications have been developed and implemented to enable both formal and informal caregivers to have remote access to patient data so that they can respond instantly to any abnormalities of in-home patients. The aim of this technology is to give both patients and relatives better control of the health care, reduce the burden on informal caregivers and reduce visits to hospitals and thus result in a better quality of life for both the patient and his/her family. To facilitate their widespread adoption, remote home-monitoring systems take advantage of the low-cost features and popularity of the Internet and PCs, but are inherently exposed to several security risks, such as virus and denial-of-service (DoS) attacks. These security threats exist as long as the in-home PC is directly accessible by remote-monitoring users over the Internet. The purpose of the study reported in this paper was to improve the security of such systems, with the proposed architecture aimed at increasing the system availability and confidentiality of patient information. A broker server is introduced between the remote-monitoring devices and the in-home PCs. This topology removes direct access to the in-home PC, and a firewall can be configured to deny all inbound connections while the remote home-monitoring application is operating. This architecture helps to transfer the security risks from the in-home PC to the managed broker server, on which more advanced security measures can be implemented. The pros and cons of this novel architecture design are also discussed and summarized.

  19. Type 2 diabetes and impaired glucose tolerance are associated with word memory source monitoring recollection deficits but not simple recognition familiarity deficits following water, low glycaemic load, and high glycaemic load breakfasts.

    PubMed

    Lamport, Daniel J; Lawton, Clare L; Mansfield, Michael W; Moulin, Chris A J; Dye, Louise

    2014-01-30

    It has been established that type 2 diabetes, and to some extent, impaired glucose tolerance (IGT), are associated with general neuropsychological impairments in episodic memory. However, the effect of abnormalities in glucose metabolism on specific retrieval processes such as source monitoring has not been investigated. The primary aim was to investigate the impact of type 2 diabetes and IGT on simple word recognition (familiarity) and complex source monitoring (recollection). A secondary aim was to examine the effect of acute breakfast glycaemic load manipulations on episodic memory. Data are presented from two separate studies; (i) 24 adults with type 2 diabetes and 12 controls aged 45-75years, (ii) 18 females with IGT and 47 female controls aged 30-50years. Controls were matched for age, IQ, BMI, waist circumference, and depression. Recognition of previously learned words and memory for specifically which list a previously learned word had appeared in (source monitoring) was examined at two test sessions during the morning after consumption of low glycaemic load, high glycaemic load and water breakfasts according to a counterbalanced, crossover design. Type 2 diabetes (p<0.05) and IGT (p<0.01) were associated with significant source monitoring recollection deficits but not impairments in familiarity. Impairments were only observed in the late postprandial stage at the second test session. These impairments were not attenuated by the breakfast glycaemic load manipulations. Isolated source monitoring recollection deficits indicate that abnormalities in glucose metabolism are not detrimental for global episodic memory processes. This enhances our understanding of how metabolic disorders are associated with memory impairments. © 2013.

  20. CHRONOBIOLOGY OF HIGH BLOOD PRESSURE

    PubMed Central

    Cornélissen, G.; Halberg, F.; Bakken, E. E.; Wang, Z.; Tarquini, R.; Perfetto, F.; Laffi, G.; Maggioni, C.; Kumagai, Y.; Homolka, P.; Havelková, A.; Dušek, J.; Svačinová, H.; Siegelová, J.; Fišer, B.

    2008-01-01

    BIOCOS, the project aimed at studying BIOlogical systems in their COSmos, has obtained a great deal of expertise in the fields of blood pressure (BP) and heart rate (HR) monitoring and of marker rhythmometry for the purposes of screening, diagnosis, treatment, and prognosis. Prolonging the monitoring reduces the uncertainty in the estimation of circadian parameters; the current recommendation of BIOCOS requires monitoring for at least 7 days. The BIOCOS approach consists of a parametric and a non-parametric analysis of the data, in which the results from the individual subject are being compared with gender- and age-specified reference values in health. Chronobiological designs can offer important new information regarding the optimization of treatment by timing its administration as a function of circadian and other rhythms. New technological developments are needed to close the loop between the monitoring of blood pressure and the administration of antihypertensive drugs. PMID:19122770

  1. Gaussian processes for personalized e-health monitoring with wearable sensors.

    PubMed

    Clifton, Lei; Clifton, David A; Pimentel, Marco A F; Watkinson, Peter J; Tarassenko, Lionel

    2013-01-01

    Advances in wearable sensing and communications infrastructure have allowed the widespread development of prototype medical devices for patient monitoring. However, such devices have not penetrated into clinical practice, primarily due to a lack of research into "intelligent" analysis methods that are sufficiently robust to support large-scale deployment. Existing systems are typically plagued by large false-alarm rates, and an inability to cope with sensor artifact in a principled manner. This paper has two aims: 1) proposal of a novel, patient-personalized system for analysis and inference in the presence of data uncertainty, typically caused by sensor artifact and data incompleteness; 2) demonstration of the method using a large-scale clinical study in which 200 patients have been monitored using the proposed system. This latter provides much-needed evidence that personalized e-health monitoring is feasible within an actual clinical environment, at scale, and that the method is capable of improving patient outcomes via personalized healthcare.

  2. Understanding Monitoring Technologies for Adults With Pain: Systematic Literature Review

    PubMed Central

    Rodríguez, Iyubanit; Gerea, Carmen; Fuentes, Carolina; Rossel, Pedro O; Marques, Maíra; Campos, Mauricio

    2017-01-01

    Background Monitoring of patients may decrease treatment costs and improve quality of care. Pain is the most common health problem that people seek help for in hospitals. Therefore, monitoring patients with pain may have significant impact in improving treatment. Several studies have studied factors affecting pain; however, no previous study has reviewed the contextual information that a monitoring system may capture to characterize a patient’s situation. Objective The objective of this study was to conduct a systematic review to (1) determine what types of technologies have been used to monitor adults with pain, and (2) construct a model of the context information that may be used to implement apps and devices aimed at monitoring adults with pain. Methods A literature search (2005-2015) was conducted in electronic databases pertaining to medical and computer science literature (PubMed, Science Direct, ACM Digital Library, and IEEE Xplore) using a defined search string. Article selection was done through a process of removing duplicates, analyzing title and abstract, and then reviewing the full text of the article. Results In the final analysis, 87 articles were included and 53 of them (61%) used technologies to collect contextual information. A total of 49 types of context information were found and a five-dimension (activity, identity, wellness, environment, physiological) model of context information to monitor adults with pain was proposed, expanding on a previous model. Most technological interfaces for pain monitoring were wearable, possibly because they can be used in more realistic contexts. Few studies focused on older adults, creating a relevant avenue of research on how to create devices for users that may have impaired cognitive skills or low digital literacy. Conclusions The design of monitoring devices and interfaces for adults with pain must deal with the challenge of selecting relevant contextual information to understand the user’s situation, and not overburdening or inconveniencing users with information requests. A model of contextual information may be used by researchers to choose possible contextual information that may be monitored during studies on adults with pain. PMID:29079550

  3. SAMIRA - SAtellite based Monitoring Initiative for Regional Air quality

    NASA Astrophysics Data System (ADS)

    Schneider, Philipp; Stebel, Kerstin; Ajtai, Nicolae; Diamandi, Andrei; Horalek, Jan; Nicolae, Doina; Stachlewska, Iwona; Zehner, Claus

    2016-04-01

    Here, we present a new ESA-funded project entitled Satellite based Monitoring Initiative for Regional Air quality (SAMIRA), which aims at improving regional and local air quality monitoring through synergetic use of data from present and upcoming satellites, traditionally used in situ air quality monitoring networks and output from chemical transport models. Through collaborative efforts in four countries, namely Romania, Poland, the Czech Republic and Norway, all with existing air quality problems, SAMIRA intends to support the involved institutions and associated users in their national monitoring and reporting mandates as well as to generate novel research in this area. Despite considerable improvements in the past decades, Europe is still far from achieving levels of air quality that do not pose unacceptable hazards to humans and the environment. Main concerns in Europe are exceedances of particulate matter (PM), ground-level ozone, benzo(a)pyrene (BaP) and nitrogen dioxide (NO2). While overall sulfur dioxide (SO2) emissions have decreased in recent years, regional concentrations can still be high in some areas. The objectives of SAMIRA are to improve algorithms for the retrieval of hourly aerosol optical depth (AOD) maps from SEVIRI, and to develop robust methods for deriving column- and near-surface PM maps for the study area by combining satellite AOD with information from regional models. The benefit to existing monitoring networks (in situ, models, satellite) by combining these datasets using data fusion methods will be tested for satellite-based NO2, SO2, and PM/AOD. Furthermore, SAMIRA will test and apply techniques for downscaling air quality-related EO products to a spatial resolution that is more in line with what is generally required for studying urban and regional scale air quality. This will be demonstrated for a set of study sites that include the capitals of the four countries and the highly polluted areas along the border of Poland and the Czech Republic, and the Gorj County in Romania. All data products shall undergo a quality control, i.e. robust and independent validation. The SAMIRA consortium will further work towards a pre-operational system for improved PM10 forecasts using observational (in situ and satellite) data assimilation. SAMIRA aims to maximize project benefits by liaison with national and regional environmental protection agencies and health institutions, as well as related ESA and European initiatives such as the Copernicus Atmospheric Monitoring Services (CAMS).

  4. Check & Connect. What Works Clearinghouse Intervention Report. Updated May 2015

    ERIC Educational Resources Information Center

    What Works Clearinghouse, 2015

    2015-01-01

    "Check & Connect" aims to help students stay in school by continually monitoring school performance and providing individualized attention through mentoring, case management, and other supports. In 2006, the WWC published a systematic review of all the studies that examined the impact of "Check & Connect" on high school…

  5. Standardised Testing: What Space for Professional Judgement?

    ERIC Educational Resources Information Center

    Doecke, Brenton; Reynolds, Gail; Roberts, Arlene

    2002-01-01

    Gives an account of Gail Reynolds's experience in administrating the DART (Developmental assessment resource for teachers) and AIM (Achievement improvement monitor) tests at her school. Reflects on how the test results compared with her own judgments of the literacy abilities of individual students in her class. Offers four case studies that draw…

  6. Monitoring and Evaluating Learning.

    ERIC Educational Resources Information Center

    Briggs, Ann R. J.

    This document is a chapter in "The Principles and Practice of Educational Management," which aims to provide a systematic and analytical introduction to the study of educational management. The structure of the book reflects the main substantive areas of educational leadership and management, and most of the major themes are covered in the…

  7. Open Educational Resources: Staff Attitudes and Awareness

    ERIC Educational Resources Information Center

    Rolfe, Vivien

    2012-01-01

    Attitudes are changing in education globally to promote the open sharing of educational courses and resources. The aim of this study was to explore staff awareness and attitudes towards "open educational resources" (OER) as a benchmark for monitoring future progress. Faculty staff (n = 6) were invited to participate in semi-structured…

  8. Differences in staining intensities affect reported occurrences and concentrations of Giardia spp. in surface drinking water sources

    EPA Science Inventory

    Aim USEPA Method 1623, or its equivalent, is currently used to monitor for protozoan contamination of surface drinking water sources worldwide. At least three approved staining kits used for detecting Cryptosporidium and Giardia are commercially available. This study focuses on ...

  9. 76 FR 70729 - Agency Forms Undergoing Paperwork Reduction Act Review

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-15

    ..., and behavior related to the campaign and monitoring early child development. The project aims to... children has an autism spectrum disorder in 2006. Today, autism is recognized in many circles as an... communities participating in both the 2002 and 2006 studies observed an increase in identified ASD prevalence...

  10. Temperature - Emissivity Separation Assessment in a Sub-Urban Scenario

    NASA Astrophysics Data System (ADS)

    Moscadelli, M.; Diani, M.; Corsini, G.

    2017-10-01

    In this paper, a methodology that aims at evaluating the effectiveness of different TES strategies is presented. The methodology takes into account the specific material of interest in the monitored scenario, sensor characteristics, and errors in the atmospheric compensation step. The methodology is proposed in order to predict and analyse algorithms performances during the planning of a remote sensing mission, aimed to discover specific materials of interest in the monitored scenario. As case study, the proposed methodology is applied to a real airborne data set of a suburban scenario. In order to perform the TES problem, three state-of-the-art algorithms, and a recently proposed one, are investigated: Temperature-Emissivity Separation '98 (TES-98) algorithm, Stepwise Refining TES (SRTES) algorithm, Linear piecewise TES (LTES) algorithm, and Optimized Smoothing TES (OSTES) algorithm. At the end, the accuracy obtained with real data, and the ones predicted by means of the proposed methodology are compared and discussed.

  11. GIS Mapping and Monitoring of Health Problems Among the Elderly.

    PubMed

    Dermatis, Zacharias; Tsaloukidis, Nikolaos; Zacharopoulou, Georgia; Lazakidou, Athina

    2017-01-01

    The electronic survey in conjunction with GIS in the current study aims at presenting the needs and health problems of the elderly in individual Open Elderly Care Centres in Greece. The online GIS survey enables the continuous monitoring and developing of the health problems of the elderly and helps them in their early care by the healthcare units. GIS survey123 is a customizable tool, which can be used to conduct research that is then published on an Android, iOS, and web platform. The ArcGIS software was used for the geographic mapping of data collected from a wide range of sources, so that health care professionals can investigate the factors associated with the onset of the diseases. Also, direct geographic mapping aims at identifying health problems of the elderly in Greece and transferring information to health care professionals in order to impose proper control measures in a very small period of time.

  12. Nonylphenol: Properties, legislation, toxicity and determination.

    PubMed

    Araujo, Frederico G DE; Bauerfeldt, Glauco F; Cid, Yara Peluso

    2017-08-07

    This paper aims to gather and discuss important information about nonylphenol, such as physical chemistry properties, toxicity and analytical methods in various matrices. As a degradation product of ethoxylated alkylphenols, nonylphenol presents a higher degree of reactivity than its precursor. Due to its harmful effects on the environment, use and production of nonylphenol has been banned in European Union countries, alongside their precursors. The guide on quality of drinking water (USEPA) recommends a maximum concentration of 28 µg L-1 for fresh water. In Brazil, there is no clear legislation containing values ​​of maximum concentration of nonylphenol. Due to this lack of regulation, a continuous monitoring is necessary of this pollutant in environmental samples. This paper aims to encourage further studies on nonylphenol, seen as a critical environmental pollutant. For proper monitoring is necessary to have reliable analytical methods and easy to perform in routine analysis.

  13. Measuring Progress Toward Universal Health Coverage: Does the Monitoring Framework of Bangladesh Need Further Improvement?

    PubMed

    Gupta, Rajat Das; Shahabuddin, Asm

    2018-01-08

    This review aimed to compare Bangladesh's Universal Health Coverage (UHC) monitoring framework with the global-level recommendations and to find out the existing gaps of Bangladesh's UHC monitoring framework compared to the global recommendations. In order to reach the aims of the review, we systematically searched two electronic databases - PubMed and Google Scholar - by using appropriate keywords to select articles that describe issues related to UHC and the monitoring framework of UHC applied globally and particularly in Bangladesh. Four relevant documents were found and synthesized. The review found that Bangladesh incorporated all of the recommendations suggested by the global monitoring framework regarding mentoring the financial risk protection and equity perspective. However, a significant gap in the monitoring framework related to service coverage was observed. Although Bangladesh has a significant burden of mental illnesses, cataract, and neglected tropical diseases, indicators related to these issues were absent in Bangladesh's UHC framework. Moreover, palliative-care-related indicators were completely missing in the framework. The results of this review suggest that Bangladesh should incorporate these indicators in their UHC monitoring framework in order to track the progress of the country toward UHC more efficiently and in a robust way.

  14. A Structural and Functional Model of Teachers' Monitoring Skills Development

    ERIC Educational Resources Information Center

    Masalimova, Alfiya R.; Barinova, Nataliya A.

    2016-01-01

    The relevance of the present issue is caused by a strong need to conduct monitoring processes in all types of teaching processes and a poor development of theoretical, content and technological, scientific and methodological material for teachers' monitoring skills development during their teaching practice. The aim of the article is to create and…

  15. Teacher Quality, Appraisal and Development: The Flaws in the IQMS

    ERIC Educational Resources Information Center

    De Clerq, Francine

    2008-01-01

    This article addresses the issue of how to monitor and develop the quality of teaching in schools by identifying the international lessons of teacher appraisal, monitoring and support systems and by interrogating the recently introduced South African Integrated Quality Management System (IQMS). The aim is to show why teacher monitoring and…

  16. Parental Monitoring and Adolescent Problem Behaviors: How Much Do We Really Know?

    ERIC Educational Resources Information Center

    Keijsers, Loes

    2016-01-01

    This article aims to provide a critical analysis of how much we know about the effectiveness of parental monitoring in preventing adolescent delinquency. First, it describes the historical developments in parental monitoring research. Second, it explains why it is uncertain whether causal inferences can be drawn from contemporary research findings…

  17. Immortal time bias and survival in patients who self-monitor blood glucose in the Retrolective Study: self-monitoring of Blood Glucose and Outcome in Patients with Type 2 Diabetes (ROSSO).

    PubMed

    Hoffmann, F; Andersohn, F

    2011-02-01

    In the February 2006 issue of Diabetologia, the observational Retrolective Study: Self-monitoring of Blood Glucose and Outcome in Patients with Type 2 Diabetes (ROSSO) reported a 51% reduction in the risk of all-cause mortality in patients with type 2 diabetes who performed self-monitoring of blood glucose (SMBG). However, these impressive benefits conflict with results from observational studies and randomised controlled trials. We aimed to show that these findings are caused by a flawed design that introduced immortal time bias. We illustrate the bias in the ROSSO study and demonstrate that it is large enough to completely explain the apparently protective effect of SMBG on all-cause mortality. In the ROSSO study, patients were classified as exposed to SMBG for their whole follow-up time if they performed self-monitoring for at least 1 year during the study period. Thus, the time between cohort entry and the date after 1 year self-monitoring was performed is unavoidably 'immortal' for patients with SMBG. Patients had to survive at least 1 year to be classified as exposed to this intervention and were artificially 'protected' from death. Based on published information, the total amount of misclassified immortal person-time in the SMBG group is at least 5,082 of 9,248 person-years at risk (55%). After re-classification of immortal person-time as unexposed, the unadjusted relative risk changed from 0.59 to 1.95. The apparently protective effect of SMBG on all-cause mortality observed in the ROSSO study is completely explained by immortal time bias.

  18. Parental Monitoring, Peer Activities and Alcohol Use: A Study Based on Data on Swedish Adolescents

    ERIC Educational Resources Information Center

    Bergh, Daniel; Hagquist, Curt; Starrin, Bengt

    2011-01-01

    Aim: This study investigates the association between two types of social relations during leisure time (to parents and peers) and the frequency of alcohol use among Swedish adolescents, taking possible interaction effects into account. Methods: The data were collected during the 1995-2005 time period by using a questionnaire handed out in the…

  19. The Neural Bases of Event Monitoring across Domains: a Simultaneous ERP-fMRI Study

    PubMed Central

    Tarantino, Vincenza; Mazzonetto, Ilaria; Formica, Silvia; Causin, Francesco; Vallesi, Antonino

    2017-01-01

    The ability to check and evaluate the environment over time with the aim to detect the occurrence of target stimuli is supported by sustained/tonic as well as transient/phasic control processes, which overall might be referred to as event monitoring. The neural underpinning of sustained attentional control processes involves a fronto-parietal network. However, it has not been well-defined yet whether this cortical circuit acts irrespective of the specific material to be monitored and whether this mediates sustained as well as transient monitoring processes. In the current study, the functional activity of brain during an event monitoring task was investigated and compared between two cognitive domains, whose processing is mediated by differently lateralized areas. Namely, participants were asked to monitor sequences of either faces (supported by right-hemisphere regions) or tools (left-hemisphere). In order to disentangle sustained from transient components of monitoring, a simultaneous EEG-fMRI technique was adopted within a block design. When contrasting monitoring versus control blocks, the conventional fMRI analysis revealed the sustained involvement of bilateral fronto-parietal regions, in both task domains. Event-related potentials (ERPs) showed a more positive amplitude over frontal sites in monitoring compared to control blocks, providing evidence of a transient monitoring component. The joint ERP-fMRI analysis showed that, in the case of face monitoring, this transient component relies on right-lateralized areas, including the inferior parietal lobule and the middle frontal gyrus. In the case of tools, no fronto-parietal areas correlated with the transient ERP activity, suggesting that in this domain phasic monitoring processes were masked by tonic ones. Overall, the present findings highlight the role of bilateral fronto-parietal regions in sustained monitoring, independently of the specific task requirements, and suggest that right-lateralized areas subtend transient monitoring processes, at least in some task contexts. PMID:28785212

  20. Evaluating hazardous air pollutants in Australia.

    PubMed

    Hinwood, A L; Di Marco, P N

    2002-12-27

    Hazardous air pollutants (HAPS) have been evaluated for their health and environmental significance on a targeted and campaign basis in Australia until recently. Individual States and Territories have been undertaking targeted monitoring studies and have numerous control strategies aimed at controlling HAPS emissions with the focus largely on volatile organic compounds (VOCs), polycyclic aromatic hydrocarbons (PAHs) and selected heavy metals, with some limited work on exposure assessment. There has been little evaluation of the potential health or environmental effects of the monitored concentrations of these substances and few toxicological or epidemiological studies have been conducted-none in the community setting in Australia. Moreover, there has not been an agreed method for assessing risks from HAPS in ambient air, with different jurisdictions utilising different international benchmarks. Recently, the National Environmental Health (EnHealth) Council commenced developing a risk assessment methodology, which is being used in the development of ambient air quality guidelines for selected HAPS in Western Australia. In 1999, the Commonwealth Government established the Living Cities-Toxics Program, designed to assess the state of knowledge on HAPS in Australia with the aims of identifying and prioritising HAPS, identifying information gaps and informing the development of national air quality standards and national management strategies. The Commonwealth Government commenced a number of projects in 2000 to progress these aims.

  1. The Automated Instrumentation and Monitoring System (AIMS): Design and Architecture. 3.2

    NASA Technical Reports Server (NTRS)

    Yan, Jerry C.; Schmidt, Melisa; Schulbach, Cathy; Bailey, David (Technical Monitor)

    1997-01-01

    Whether a researcher is designing the 'next parallel programming paradigm', another 'scalable multiprocessor' or investigating resource allocation algorithms for multiprocessors, a facility that enables parallel program execution to be captured and displayed is invaluable. Careful analysis of such information can help computer and software architects to capture, and therefore, exploit behavioral variations among/within various parallel programs to take advantage of specific hardware characteristics. A software tool-set that facilitates performance evaluation of parallel applications on multiprocessors has been put together at NASA Ames Research Center under the sponsorship of NASA's High Performance Computing and Communications Program over the past five years. The Automated Instrumentation and Monitoring Systematic has three major software components: a source code instrumentor which automatically inserts active event recorders into program source code before compilation; a run-time performance monitoring library which collects performance data; and a visualization tool-set which reconstructs program execution based on the data collected. Besides being used as a prototype for developing new techniques for instrumenting, monitoring and presenting parallel program execution, AIMS is also being incorporated into the run-time environments of various hardware testbeds to evaluate their impact on user productivity. Currently, the execution of FORTRAN and C programs on the Intel Paragon and PALM workstations can be automatically instrumented and monitored. Performance data thus collected can be displayed graphically on various workstations. The process of performance tuning with AIMS will be illustrated using various NAB Parallel Benchmarks. This report includes a description of the internal architecture of AIMS and a listing of the source code.

  2. Monitoring hand, foot and mouth disease by combining search engine query data and meteorological factors.

    PubMed

    Huang, Da-Cang; Wang, Jin-Feng

    2018-01-15

    Hand, foot and mouth disease (HFMD) has been recognized as a significant public health threat and poses a tremendous challenge to disease control departments. To date, the relationship between meteorological factors and HFMD has been documented, and public interest of disease has been proven to be trackable from the Internet. However, no study has explored the combination of these two factors in the monitoring of HFMD. Therefore, the main aim of this study was to develop an effective monitoring model of HFMD in Guangzhou, China by utilizing historical HFMD cases, Internet-based search engine query data and meteorological factors. To this end, a case study was conducted in Guangzhou, using a network-based generalized additive model (GAM) including all factors related to HFMD. Three other models were also constructed using some of the variables for comparison. The results suggested that the model showed the best estimating ability when considering all of the related factors. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Scaling up the use of remote patient monitoring in Canada.

    PubMed

    Gheorghiu, Bobby; Ratchford, Fraser

    2015-01-01

    Evidence supporting the use of remote patient monitoring (RPM) as a cost-effective means of keeping patients from being re-admitted to hospitals or making repeated emergency department visits is growing, especially for the treatment of chronic obstructive pulmonary disease (COPD) and congestive heart failure (CHF). A recent study funded by Canada Health Infoway, titled Connecting Patients with Providers: A Pan-Canadian Study on Remote Patient Monitoring, aimed to assess the current state of RPM solutions; to examine the evidence for patient and health system benefits achieved both in Canada and internationally; and to determine the critical success factors needed to support further investment and scaling-up of RPM solutions across the Canadian health care system. Break-even analysis of four different implementations reviewed in this study demonstrated that RPM programs can be viable and sustainable for large and small jurisdictions; however, more evidence is needed with regards to a number of potential applications for RPM beyond the management of COPD and CHF.

  4. Radar Interferometry for Monitoring the Vibration Characteristics of Buildings and Civil Structures: Recent Case Studies in Spain

    PubMed Central

    Luzi, Guido; Crosetto, Michele; Fernández, Enric

    2017-01-01

    The potential of a coherent microwave sensor to monitor the vibration characteristics of civil structures has been investigated in the past decade, and successful case studies have been published by different research teams. This remote sensing technique is based on the interferometric processing of real aperture radar acquisitions. Its capability to estimate, simultaneously and remotely, the displacement of different parts of the investigated structures, with high accuracy and repeatability, is its main advantage with respect to conventional sensors. A considerable amount of literature on this technique is available, including various case studies aimed at testing the ambient vibration of bridges, buildings, and towers. In the last years, this technique has been used in Spain for civil structures monitoring. In this paper, three examples of such case studies are described: the monitoring of the suspended bridge crossing the Ebro River at Amposta, the communications tower of Collserola in Barcelona, and an urban building located in Vilafranca del Penedès, a small town close to Barcelona. This paper summarizes the main outcomes of these case studies, underlining the advantages and limitations of the sensors currently available, and concluding with the possible improvements expected from the next generation of sensors. PMID:28338604

  5. Assessment of zero drift in the Codman intracranial pressure monitor: a study from 2 neurointensive care units.

    PubMed

    Al-Tamimi, Yahia Z; Helmy, Adel; Bavetta, Seb; Price, Stephen J

    2009-01-01

    Intraparenchymal monitoring devices play an important role in the daily management of head injury and other critically ill neurosurgical patients. Although zero drift data exist for the Camino system (Camino Laboratories, San Diego, CA), only in vitro data exist for the Codman system (Codman and Shurtleff, Inc., Raynham, MA). The aim of this study was to assess the extent of zero drift for the Codman intracranial pressure (ICP) monitor in patients being monitored in 2 neurointensive care units. This was a prospective study conducted at 2 neurointensive care units. Eighty-eight patients who required ICP monitoring and who presented to the 2 neurosurgical departments, Center 1 (n = 48) and Center 2 (n = 40), were recruited for participation. The duration of ICP monitoring was noted, as was the resultant pressure reading in normal saline on removing the ICP monitor (zero drift). The median absolute zero drift for the group was 2.0 mm Hg (interquartile range, 1-3 mm Hg). The median time in situ was 108 hours (interquartile range, 69-201 hours). There was a positive correlation between the drift and time of the probe spent in situ (Spearman's correlation coefficient = 0.342; P = 0.001). Of the readings, 20 and 2% showed a drift greater than 5 and 10 mm Hg in magnitude, respectively. These data demonstrate that a small amount of zero drift exists in ICP monitors and that this drift increases with time. The wide range in the data demonstrates that some drift readings are quite excessive. This reinforces the school of thought that, although ICP readings contribute significantly to the management of neurosurgical patients, they should be interpreted carefully and in conjunction with clinical and radiological assessment of patients.

  6. Patient, Treatment, and Health Care Utilization Variables Associated with Adherence to Metabolic Monitoring Practices in Children and Adolescents Taking Second-Generation Antipsychotics.

    PubMed

    Coughlin, Mary; Goldie, Catherine Lindsay; Tranmer, Joan; Khalid-Khan, Sarosh; Tregunno, Deborah

    2018-04-01

    Children and adolescents with a range of psychiatric disorders are increasingly being prescribed atypical or second-generation antipsychotics (SGAs). While SGAs are effective at treating conduct and behavioural symptoms, they infer significant cardiometabolic risk. This study aims to explore what patient, treatment, and health care utilization variables are associated with adherence to Canadian Alliance for Monitoring Effectiveness and Safety of Antipsychotics in Children (CAMESA) metabolic monitoring guidelines. A retrospective chart review of 294 children and adolescents accessing a large outpatient psychiatry setting within a 2-year study period (2014-2016) was conducted. Baseline and follow-up metabolic monitoring, demographic, treatment, and health care utilization variables were then assessed over a 1-year period of interest. Metabolic monitoring practices did not adhere to CAMESA guidelines and were very poor over the 1-year observation period. There were significant differences between children (ages 4-12 years, n = 99) and adolescents (ages 13-18 years, n = 195). In adolescents, factors associated with any baseline metabolic monitoring were a higher number of psychiatry visits (odds ratio [OR], 1.2; 95% confidence interval [CI], 1.10 to 1.41), longer duration of contact (OR, 14; 95% CI, 2.31 to 82.4), and use of other non-SGA medications (OR, 3.2; 95% CI, 1.17 to 8.94). Among children, having an emergency room visit (OR, 3.4; 95% CI, 1.01 to 11.71) and taking aripiprazole (OR, 7.4; 95% CI, 2.02 to 27.45) increased the odds of receiving baseline metabolic monitoring. Findings from this study highlight the need for better metabolic monitoring for children and adolescents taking SGAs. Enhanced focus on opportunities for multidisciplinary collaboration is needed to improve the quality of care offered to this population.

  7. All that glisters is not gold: a comparison of electronic monitoring versus filled prescriptions--an observational study.

    PubMed

    Wetzels, Gwenn E C; Nelemans, Patricia J; Schouten, Jan S A G; van Wijk, Boris L G; Prins, Martin H

    2006-02-10

    Poor compliance with antihypertensive medication is assumed to be an important reason for unsatisfactory control of blood pressure. Poor compliance is difficult to detect. Each method of measuring compliance has its own strengths and weaknesses. The aim of the present study was to compare patient compliance with antihypertensive drugs as measured by two methods, electronic monitoring versus refill compliance. 161 patients with a diagnosis of hypertension for at least a year prior to inclusion, and inadequate blood pressure control (systolic blood pressure > or = 160 mmHg and/or diastolic blood pressure > or = 95 mmHg) despite the use of antihypertensive drugs, were included. Patients' pharmacy records from 12 months prior to inclusion were obtained. Refill compliance was calculated as the number of days for which the pills were prescribed divided by the total number of days in this period. After inclusion compliance was measured with an electronic monitor that records time and date of each opening of the pillbox. Agreement between both compliance measures was calculated using Spearman's correlation coefficient and Cohen's kappa coefficient. There was very little agreement between the two measures. Whereas refill compliance showed a large range of values, compliance as measured by electronic monitoring was high in almost all patients with estimates between 90% and 100%. Cohen's kappa coefficient was 0.005. While electronic monitoring is often considered to be the gold standard for compliance measurements, our results suggest that a short-term electronic monitoring period with the patient being aware of electronic monitoring is probably insufficient to obtain valid compliance data. We conclude that there is a strong need for more studies that explore the effect of electronic monitoring on patient's compliance.

  8. Three-month validation of a turbuhaler electronic monitoring device: implications for asthma clinical trial use.

    PubMed

    Pilcher, Janine; Shirtcliffe, Philippa; Patel, Mitesh; McKinstry, Steve; Cripps, Terrianne; Weatherall, Mark; Beasley, Richard

    2015-01-01

    Electronic monitoring of inhaled asthma therapy is suggested as the 'gold standard' for measuring patterns of medication use in clinical trials. The SmartTurbo (Adherium (NZ) Ltd, Auckland, New Zealand) is an electronic monitor for use with a turbuhaler device (AstraZeneca, UK). The aim of this study was to determine the accuracy of the SmartTurbo in recording Symbicort actuations over a 12-week period of use. Twenty SmartTurbo monitors were attached to the base of 20 Symbicort turbuhalers. Bench testing in a research facility was undertaken on days 0, 5, 6, 7, 8, 9, 14, 21, 28, 56 and 84. Patterns of 'low-use' (2 sets of 2 actuations on the same day) and 'high-use' (2 sets of 8 actuations on the same day) were performed. The date and time of actuations were recorded in a paper diary and compared with data uploaded from the SmartTurbo monitors. 2800 actuations were performed. Monitor sensitivity was 99.9% with a lower 97.5% confidence bound of 99.6%. The positive predictive value was 99.9% with a 97.5% lower confidence bound of 99.7%. Accuracy was not affected by whether the pattern of inhaler use was low or high, or whether there was a delay in uploading the actuation data. The SmartTurbo monitor is highly accurate in recording and retaining electronic data in this 12-week bench study. It can be recommended for use in clinical trial settings, in which quality control systems are incorporated into study protocols to ensure accurate data acquisition.

  9. Cleanrooms and tissue banking how happy I could be with either GMP or GTP?

    PubMed

    Klykens, J; Pirnay, J-P; Verbeken, G; Giet, O; Baudoux, E; Jashari, R; Vanderkelen, A; Ectors, N

    2013-12-01

    The regulatory framework of tissue banking introduces a number of requirements for monitoring cleanrooms for processing tissue or cell grafts. Although a number of requirements were clearly defined, some requirements are open for interpretation. This study aims to contribute to the interpretation of GMP or GTP guidelines for tissue banking. Based on the experience of the participating centers, the results of the monitoring program were evaluated to determine the feasibility of a cleanroom in tissue banking and the monitoring program. Also the microbial efficacy of a laminar airflow cabinet and an incubator in a cleanroom environment was evaluated. This study indicated that a monitoring program of a cleanroom at rest in combination with (final) product testing is a feasible approach. Although no statistical significance (0.90 < p < 0.95) was found there is a strong indication that a Grade D environment is not the ideal background environment for a Grade A obtained through a laminar airflow cabinet. The microbial contamination of an incubator in a cleanroom is limited but requires closed containers for tissue and cell products.

  10. Test results for the evaluation of a glucometer for use under hyperbaric conditions: Technical report.

    PubMed

    Tsouras, Theo

    2017-01-01

    This study aimed to evaluate a recently developed equipment test method by assessing the safe and accurate functioning of the Abbott Optium FreeStyle H portable blood glucose monitor for use in the Alfred Hospital's hyperbaric chamber. The results of this study indicate that the test method can be used successfully to evaluate instruments and/or devices for use in the hyperbaric environment. The evaluation initially found that this particular glucose monitor contained a lithium battery which can be hazardous when used in the hyperbaric environment. However, upon further inspection it was determined the battery posed minimal risk for fire and explosion due to its small capacity and design application. The results indicate that the Abbott Optium FreeStyle H blood glucose monitor operated normally when used in the hyperbaric chamber. This glucometer was found to perform within the calibration specification requirements for accuracy at all stages of a typical hyperbaric treatment and as such the Abbott Optium FreeStyle H blood glucose monitor was deemed safe for use in the hyperbaric chamber at the Alfred Hospital. Copyright© Undersea and Hyperbaric Medical Society.

  11. Designing optimized multi-species monitoring networks to detect range shifts driven by climate change: a case study with bats in the North of Portugal.

    PubMed

    Amorim, Francisco; Carvalho, Sílvia B; Honrado, João; Rebelo, Hugo

    2014-01-01

    Here we develop a framework to design multi-species monitoring networks using species distribution models and conservation planning tools to optimize the location of monitoring stations to detect potential range shifts driven by climate change. For this study, we focused on seven bat species in Northern Portugal (Western Europe). Maximum entropy modelling was used to predict the likely occurrence of those species under present and future climatic conditions. By comparing present and future predicted distributions, we identified areas where each species is likely to gain, lose or maintain suitable climatic space. We then used a decision support tool (the Marxan software) to design three optimized monitoring networks considering: a) changes in species likely occurrence, b) species conservation status, and c) level of volunteer commitment. For present climatic conditions, species distribution models revealed that areas suitable for most species occur in the north-eastern part of the region. However, areas predicted to become climatically suitable in the future shifted towards west. The three simulated monitoring networks, adaptable for an unpredictable volunteer commitment, included 28, 54 and 110 sampling locations respectively, distributed across the study area and covering the potential full range of conditions where species range shifts may occur. Our results show that our framework outperforms the traditional approach that only considers current species ranges, in allocating monitoring stations distributed across different categories of predicted shifts in species distributions. This study presents a straightforward framework to design monitoring schemes aimed specifically at testing hypotheses about where and when species ranges may shift with climatic changes, while also ensuring surveillance of general population trends.

  12. Utilization of Quantitative EEG Trends for Critical Care Continuous EEG Monitoring: A Survey of Neurophysiologists.

    PubMed

    Swisher, Christa B; Sinha, Saurabh R

    2016-12-01

    Quantitative EEG (QEEG) can be used to assist with review of large amounts of data generated by critical care continuous EEG monitoring. This study aimed to identify current practices regarding the use of QEEG in critical care continuous EEG monitoring of critical care patients. An online survey was sent to 796 members of the American Clinical Neurophysiology Society (ACNS), instructing only neurophysiologists to participate. The survey was completed by 75 neurophysiologists that use QEEG in their practice. Survey respondents reported that neurophysiologists and neurophysiology fellows are most likely to serve as QEEG readers (97% and 52%, respectively). However, 21% of respondents reported nonneurophysiologists are also involved with QEEG interpretation. The majority of nonneurophysiologist QEEG data review is aimed to alert neurophysiologists to periods of concern, but 22% reported that nonneurophysiologists use QEEG to directly guide clinical care. Quantitative EEG was used most frequently for seizure detection (92%) and burst suppression monitoring (59%). A smaller number of respondents use QEEG for monitoring the depth of sedation (29%), ischemia detection (28%), vasospasm detection (28%) and prognosis after cardiac arrest (21%). About half of the respondents do not review every page of the raw critical care continuous EEG record when using QEEG. Respondents prefer a panel of QEEG trends displayed as hemispheric data, when applicable. There is substantial variability regarding QEEG trend preferences for seizure detection and ischemia detection. QEEG is being used by neurophysiologists and nonneurophysiologists for applications beyond seizure detection, but practice patterns vary widely. There is a need for standardization of QEEG methods and practices.

  13. Older adults' perceptions of technologies aimed at falls prevention, detection or monitoring: a systematic review.

    PubMed

    Hawley-Hague, Helen; Boulton, Elisabeth; Hall, Alex; Pfeiffer, Klaus; Todd, Chris

    2014-06-01

    Over recent years a number of Information and Communication Technologies (ICTs) have emerged aiming at falls prevention, falls detection and alarms for use in case of fall. There are also a range of ICT interventions, which have been created or adapted to be pro-active in preventing falls, such as those which provide strength and balance training to older adults in the prevention of falls. However, there are issues related to the adoption and continued use of these technologies by older adults. This review provides an overview of older adults' perceptions of falls technologies. We undertook systematic searches of MEDLINE, EMBASE, CINAHL and PsychINFO, COMPENDEX and the Cochrane database. Key search terms included 'older adults', 'seniors', 'preference', 'attitudes' and a wide range of technologies, they also included the key word 'fall*'. We considered all studies that included older adults aged 50 and above. Studies had to include technologies related specifically to falls prevention, detection or monitoring. The Joanna Briggs Institute (JBI) tool and the Quality Assessment Tool for Quantitative Studies by the Effective Public Health Practice Project (EPHPP) were used. We identified 76 potentially relevant papers. Some 21 studies were considered for quality review. Twelve qualitative studies, three quantitative studies and 6 mixed methods studies were included. The literature related to technologies aimed at predicting, monitoring and preventing falls suggest that intrinsic factors related to older adults' attitudes around control, independence and perceived need/requirements for safety are important for their motivation to use and continue using technologies. Extrinsic factors such as usability, feedback gained and costs are important elements which support these attitudes and perceptions. Positive messages about the benefits of falls technologies for promoting healthy active ageing and independence are critical, as is ensuring that the technologies are simple, reliable and effective and tailored to individual need. The technologies need to be clearly described in research and older peoples' attitudes towards different sorts of technologies must be clarified if specific recommendations are to be made. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  14. Development of river sediment monitoring in Croatia

    NASA Astrophysics Data System (ADS)

    Frančišković-Bilinski, Stanislav; Bilinski, Halka; Mlakar, Marina; Maldini, Krešimir

    2017-04-01

    Establishment of regular river sediment monitoring, in addition to water monitoring, is very important. Unlike water, which represents the current state of a particular watercourse, sediment represents a sort of record of the state of pollution in the long run. Sediment monitoring is crucial to gain a real insight into the status of pollution of particular watercourses and to determine trends over a longer period of time. First scientific investigations of river sediment geochemistry in Croatia started 1989 in the Krka River estuary [1], while first systematic research of a river basin in Croatia was performed 2005 in Kupa River drainage basin [2]. Up to now, several detailed studies of both toxic metals and organic pollutants have been conducted in this drainage basin and some other rivers, also Croatian scientists participated in river sediment research in other countries. In 2008 Croatian water authorities (Hrvatske Vode) started preliminary sediment monitoring program, what was successfully conducted. In the first year of preliminary program only 14 stations existed, while in 2014 number of stations increased to 21. Number of monitored watercourses and of analysed parameters also increased. Current plan is to establish permanent monitoring network of river sediments throughout the state. The goal is to set up about 80 stations, which will cover all most important and most contaminated watercourses in all parts of the country [3]. Until the end of the year 2016, regular monitoring was conducted at 31 stations throughout the country. Currently the second phase of sediment monitoring program is in progress. At the moment parameters being determined on particular stations are not uniform. From inorganic compounds it is aimed to determine Cd, Pb, Ni, Hg, Cu, Cr, Zn and As on all stations. The ratio of natural concentrations of those elements vs. anthropogenic influence is being evaluated on all stations. It was found that worse situation is with Ni, Hg and Cr, who have significant anthropogenic concentrations on several locations. With other studied elements situation is much better and anthropogenic influence is not so significant. Based on own research and experience and comparing them with existing sediment quality criteria worldwide, within the current phase of monitoring program it is aimed to propose threshold values for mentioned elements, what would be base for Croatian National legislative on sediment quality. [1] Prohić, E. and Juračić, M. (1989): Heavy metals in sediments - Problems concerning determination of the anthropogenic influence. Study in the Krka River Estuary, Eastern Adriatic Coast, Yugoslavia. Environmental Geology Water Science, 13(2), 145-151. [2] Franči\\vsković-Bilinski, S. (2005): Geochemistry of stream sediments in Kupa River drainage basin [In Croatian] / Doctoral thesis. University of Zagreb, Croatia. [3] Franči\\vsković-Bilinski, S., Bilinski, H., Maldini, K. (2015): Establishing of monitoring of river sediments in Croatia. Contaminated sediments: Environmental Chemistry, Ecotoxicology and Engineering - Program and Abstract Book, Congressi Stefano Franscini, Ascona, Switzerland, 73-73.

  15. Predicting Ecstasy Use among Young People at Risk: A Prospective Study of Initially Ecstasy-Naive Subjects

    ERIC Educational Resources Information Center

    Vervaeke, Hylke K.E.; Benschop, Annemieke; Van Den Brink, Wim; Korf, Dirk J.

    2008-01-01

    Our aim is to identify predictors of first-time ecstasy use in a prospective study among young people at risk. As part of the multidisciplinary Netherlands XTC Toxicity Study (NeXT), we monitored 188 subjects aged up to 18 years who were ecstasy-naive at baseline but seemed likely to start taking ecstasy in the near future. After an 11- to…

  16. Monitoring the gingival regeneration after aesthetic surgery with optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Fernandes, Luana O.; Graça, Natalia D. R. L.; Melo, Luciana S. A.; Silva, Claudio H. V.; Gomes, Anderson S. L.

    2016-02-01

    The aim of this study was to use the Optical Coherence Tomography (OCT) technique working in spectral domain (Swept Source OCT at 1325 nm, Thorlabs, New Jersey, USA) to monitor the tissue repair in patients undergoing periodontal plastic surgery. The evaluations were done over a period of 60 days. It was observed that 15 days after periodontal surgery the gum was still in different healing process as compared to the observation after 60 days. Thus it is clear that, despite some technical limitations, the OCT is an efficient method in the evaluation of regeneration gingival.

  17. Variability of the human heart rate as a diagnostic instrument obtained by mean of a wireless monitor

    NASA Astrophysics Data System (ADS)

    Barajas Mauricio, Sánchez; Hernández González, Martha Alicia; Figueroa Vega, Nicte; Malacara Hernández, Juan Manuel; Fraga Teodoro, Córdova

    2014-11-01

    Introduction: Heart rate variability (HRV) is the cyclic measurement of RR intervals between normal beats. Aim: To determine the VFC via a wireless Polar monitor. Material and methods: 100 symptomatic menopausal women were studied for measurements of HRV were I post a Polar RS400 Watch four hrs. Results: Obtained through the fast Fourier transform, the frequency domain HRV low frequency (LF) 0.04-0.15 Hz, high frequency (HF) 0.15-0.4Hz and the ratio LF / HF. Conclusion: obtaining HRV is important for cardiovascular autonomic assessment in menopausal women.

  18. Accommodative and convergence response to computer screen and printed text

    NASA Astrophysics Data System (ADS)

    Ferreira, Andreia; Lira, Madalena; Franco, Sandra

    2011-05-01

    The aim of this work was to find out if differences exist in accommodative and convergence response for different computer monitors' and a printed text. It was also tried to relate the horizontal heterophoria value and accommodative response with the symptoms associated with computer use. Two independents experiments were carried out in this study. The first experiment was measuring the accommodative response on 89 subjects using the Grand Seiko WAM-5500 (Grand Seiko Co., Ltd., Japan). The accommodative response was measured using three computer monitors: a 17-inch cathode ray tube (CRT), two liquid crystal displays LCDs, one 17-inch (LCD17) and one 15 inches (LCD15) and a printed text. The text displayed was always the same for all the subjects and tests. A second experiment aimed to measure the value of habitual horizontal heterophoria on 80 subjects using the Von Graefe technique. The measurements were obtained using the same target presented on two different computer monitors, one 19-inch cathode ray tube (CRT) and other 19 inches liquid crystal displays (LCD) and printed on paper. A small survey about the incidence and prevalence of symptoms was performed similarly in both experiments. In the first experiment, the accommodation response was higher in the CRT and LCD's than for paper. There were not found significantly different response for both LCD monitors'. The second experiment showed that, the heterophoria values were similar for all the stimuli. On average, participants presented a small exophoria. In both experiments, asthenopia was the symptom that presented higher incidence. There are different accommodative responses when reading on paper or on computer monitors. This difference is more significant for CRT monitors. On the other hand, there was no difference in the values of convergence for the computer monitors' and paper. The symptoms associated with the use of computers are not related with the increase in accommodation and with the horizontal heterophoria values.

  19. International health research monitoring: exploring a scientific and a cooperative approach using participatory action research

    PubMed Central

    Chantler, Tracey; Cheah, Phaik Yeong; Miiro, George; Hantrakum, Viriya; Nanvubya, Annet; Ayuo, Elizabeth; Kivaya, Esther; Kidola, Jeremiah; Kaleebu, Pontiano; Parker, Michael; Njuguna, Patricia; Ashley, Elizabeth; Guerin, Philippe J; Lang, Trudie

    2014-01-01

    Objectives To evaluate and determine the value of monitoring models developed by the Mahidol Oxford Tropical Research Unit and the East African Consortium for Clinical Research, consider how this can be measured and explore monitors’ and investigators’ experiences of and views about the nature, purpose and practice of monitoring. Research design A case study approach was used within the context of participatory action research because one of the aims was to guide and improve practice. 34 interviews, five focus groups and observations of monitoring practice were conducted. Setting and participants Fieldwork occurred in the places where the monitoring models are coordinated and applied in Thailand, Cambodia, Uganda and Kenya. Participants included those coordinating the monitoring schemes, monitors, senior investigators and research staff. Analysis Transcribed textual data from field notes, interviews and focus groups was imported into a qualitative data software program (NVIVO V. 10) and analysed inductively and thematically by a qualitative researcher. The initial coding framework was reviewed internally and two main categories emerged from the subsequent interrogation of the data. Results The categories that were identified related to the conceptual framing and nature of monitoring, and the practice of monitoring, including relational factors. Particular emphasis was given to the value of a scientific and cooperative style of monitoring as a means of enhancing data quality, trust and transparency. In terms of practice the primary purpose of monitoring was defined as improving the conduct of health research and increasing the capacity of researchers and trial sites. Conclusions The models studied utilise internal and network wide expertise to improve the ethics and quality of clinical research. They demonstrate how monitoring can be a scientific and constructive exercise rather than a threatening process. The value of cooperative relations needs to be given more emphasis in monitoring activities, which seek to ensure that research protects human rights and produces reliable data. PMID:24534257

  20. Consistent indicators and methods and a scalable sample design to meet assessment, inventory, and monitoring information needs across scales

    USDA-ARS?s Scientific Manuscript database

    Within the Bureau of Land Management (BLM), as in many land management agencies throughout the world, much effort is invested in monitoring and assessment for specific management needs. The BLM Assessment, Inventory, and Monitoring (AIM) Strategy was initiated, in part, to evaluate and make recommen...

  1. Application of two quality indices as monitoring and management tools of rivers. Case study: the Imera Meridionale River, Italy.

    PubMed

    Bonanno, Giuseppe; Lo Giudice, Rosa

    2010-04-01

    On the basis of the European Water Framework Directive (2000/60), the water resources of the member states of the European Community should reach good quality standards by 2015. Although such regulations illustrate the basic points for a comprehensive and effective policy of water monitoring and management, no practical tools are provided to face and solve the issues concerning freshwater ecosystems such as rivers. The Italian government has developed a set of regulations as adoption of the European Directive but failed to indicate feasible procedures for river monitoring and management. On a local scale, Sicilian authorities have implemented monitoring networks of watersheds, aiming at describing the general conditions of rivers. However, such monitoring programs have provided a relatively fragmentary picture of the ecological conditions of the rivers. In this study, the integrated use of environmental quality indices is proposed as a methodology able to provide a practical approach to river monitoring and management. As a case study, the Imera Meridionale River, Sicily's largest river, was chosen. The water quality index developed by the U.S. National Sanitation Foundation and the floristic quality index based on the Wilhelm method were applied. The former enabled us to describe the water quality according to a spatial-temporal gradient, whereas the latter focused on the ecological quality of riparian vegetation. This study proposes a holistic view of river ecosystems by considering biotic and abiotic factors in agreement with the current European regulations. How the combined use of such indices can guide sustainable management efforts is also discussed.

  2. Monitoring Ion Track Formation Using In Situ RBS/c, ToF-ERDA, and HR-PIXE

    NASA Astrophysics Data System (ADS)

    Karlušić, Marko; Fazinić, Stjepko; Siketić, Zdravko; Tadić, Tonči; Cosic, Donny; Božičević-Mihalić, Iva; Zamboni, Ivana; Jakšić, Milko; Schleberger, Marika

    2017-09-01

    The aim of this work is to investigate feasibility of the ion beam analysis techniques for monitoring swift heavy ion track formation. First, use of the in situ Rutherford backscattering spectroscopy in channeling mode to observe damage build-up in quartz SiO2 after MeV heavy ion irradiation is demonstrated. Second, new results of the in situ grazing incidence time-of-flight elastic recoil detection analysis used for monitoring the surface elemental composition during ion tracks formation in various materials are presented. Ion tracks were found on SrTiO3, quartz SiO2, a-SiO2 and muscovite mica surfaces by atomic force microscopy, but in contrast to our previous studies on GaN and TiO2, surface stoichiometry remained unchanged.

  3. Incidents Prediction in Road Junctions Using Artificial Neural Networks

    NASA Astrophysics Data System (ADS)

    Hajji, Tarik; Alami Hassani, Aicha; Ouazzani Jamil, Mohammed

    2018-05-01

    The implementation of an incident detection system (IDS) is an indispensable operation in the analysis of the road traffics. However the IDS may, in no case, represent an alternative to the classical monitoring system controlled by the human eye. The aim of this work is to increase detection and prediction probability of incidents in camera-monitored areas. Knowing that, these areas are monitored by multiple cameras and few supervisors. Our solution is to use Artificial Neural Networks (ANN) to analyze moving objects trajectories on captured images. We first propose a modelling of the trajectories and their characteristics, after we develop a learning database for valid and invalid trajectories, and then we carry out a comparative study to find the artificial neural network architecture that maximizes the rate of valid and invalid trajectories recognition.

  4. Implementation Considerations for Multisite Clinical Trials with Cognitive Neuroscience Tasks

    PubMed Central

    Keefe, Richard S. E.; Harvey, Philip D.

    2008-01-01

    Multisite clinical trials aimed at cognitive enhancement across various neuropsychiatric conditions have employed standard neuropsychological tests as outcome measures. While these tests have enjoyed wide clinical use and have proven reliable and predictive of functional disability, a number of implementation challenges have arisen when these tests are used in clinical trials. These issues are likely to be magnified in future studies when cognitive neuroscience (CN) procedures are explored in these trials, because in their current forms CN procedures are less standardized and more difficult to teach and monitor. For multisite trials, we anticipate that the most challenging issues will include assuring tester competence, monitoring tester performance, specific challenges with complex assessment methods, and having resources available for adequate monitoring of data quality. Suggestions for overcoming these implementation challenges are offered. PMID:18495645

  5. Automated Instrumentation, Monitoring and Visualization of PVM Programs Using AIMS

    NASA Technical Reports Server (NTRS)

    Mehra, Pankaj; VanVoorst, Brian; Yan, Jerry; Lum, Henry, Jr. (Technical Monitor)

    1994-01-01

    We present views and analysis of the execution of several PVM (Parallel Virtual Machine) codes for Computational Fluid Dynamics on a networks of Sparcstations, including: (1) NAS Parallel Benchmarks CG and MG; (2) a multi-partitioning algorithm for NAS Parallel Benchmark SP; and (3) an overset grid flowsolver. These views and analysis were obtained using our Automated Instrumentation and Monitoring System (AIMS) version 3.0, a toolkit for debugging the performance of PVM programs. We will describe the architecture, operation and application of AIMS. The AIMS toolkit contains: (1) Xinstrument, which can automatically instrument various computational and communication constructs in message-passing parallel programs; (2) Monitor, a library of runtime trace-collection routines; (3) VK (Visual Kernel), an execution-animation tool with source-code clickback; and (4) Tally, a tool for statistical analysis of execution profiles. Currently, Xinstrument can handle C and Fortran 77 programs using PVM 3.2.x; Monitor has been implemented and tested on Sun 4 systems running SunOS 4.1.2; and VK uses XIIR5 and Motif 1.2. Data and views obtained using AIMS clearly illustrate several characteristic features of executing parallel programs on networked workstations: (1) the impact of long message latencies; (2) the impact of multiprogramming overheads and associated load imbalance; (3) cache and virtual-memory effects; and (4) significant skews between workstation clocks. Interestingly, AIMS can compensate for constant skew (zero drift) by calibrating the skew between a parent and its spawned children. In addition, AIMS' skew-compensation algorithm can adjust timestamps in a way that eliminates physically impossible communications (e.g., messages going backwards in time). Our current efforts are directed toward creating new views to explain the observed performance of PVM programs. Some of the features planned for the near future include: (1) ConfigView, showing the physical topology of the virtual machine, inferred using specially formatted IP (Internet Protocol) packets: and (2) LoadView, synchronous animation of PVM-program execution and resource-utilization patterns.

  6. Modeling the Dynamics of High-Grade Serous Ovarian Cancer Progression for Transvaginal Ultrasound-Based Screening and Early Detection

    PubMed Central

    Lee, Jung-Min; Levy, Doron

    2016-01-01

    High-grade serous ovarian cancer (HGSOC) represents the majority of ovarian cancers and accounts for the largest proportion of deaths from the disease. A timely detection of low volume HGSOC should be the goal of any screening studies. However, numerous transvaginal ultrasound (TVU) detection-based population studies aimed at detecting low-volume disease have not yielded reduced mortality rates. A quantitative invalidation of TVU as an effective HGSOC screening strategy is a necessary next step. Herein, we propose a mathematical model for a quantitative explanation on the reported failure of TVU-based screening to improve HGSOC low-volume detectability and overall survival.We develop a novel in silico mathematical assessment of the efficacy of a unimodal TVU monitoring regimen as a strategy aimed at detecting low-volume HGSOC in cancer-positive cases, defined as cases for which the inception of the first malignant cell has already occurred. Our findings show that the median window of opportunity interval length for TVU monitoring and HGSOC detection is approximately 1.76 years. This does not translate into reduced mortality levels or improved detection accuracy in an in silico cohort across multiple TVU monitoring frequencies or detection sensitivities. We demonstrate that even a semiannual, unimodal TVU monitoring protocol is expected to miss detectable HGSOC. Lastly, we find that circa 50% of the simulated HGSOC growth curves never reach the baseline detectability threshold, and that on average, 5–7 infrequent, rate-limiting stochastic changes in the growth parameters are associated with reaching HGSOC detectability and mortality thresholds respectively. Focusing on a malignancy poorly studied in the mathematical oncology community, our model captures the dynamic, temporal evolution of HGSOC progression. Our mathematical model is consistent with recent case reports and prospective TVU screening population studies, and provides support to the empirical recommendation against frequent HGSOC screening. PMID:27257824

  7. The Satellite based Monitoring Initiative for Regional Air quality (SAMIRA): Project summary and first results

    NASA Astrophysics Data System (ADS)

    Schneider, Philipp; Stebel, Kerstin; Ajtai, Nicolae; Diamandi, Andrei; Horalek, Jan; Nemuc, Anca; Stachlewska, Iwona; Zehner, Claus

    2017-04-01

    We present a summary and some first results of a new ESA-funded project entitled Satellite based Monitoring Initiative for Regional Air quality (SAMIRA), which aims at improving regional and local air quality monitoring through synergetic use of data from present and upcoming satellite instruments, traditionally used in situ air quality monitoring networks and output from chemical transport models. Through collaborative efforts in four countries, namely Romania, Poland, the Czech Republic and Norway, all with existing air quality problems, SAMIRA intends to support the involved institutions and associated users in their national monitoring and reporting mandates as well as to generate novel research in this area. The primary goal of SAMIRA is to demonstrate the usefulness of existing and future satellite products of air quality for improving monitoring and mapping of air pollution at the regional scale. A total of six core activities are being carried out in order to achieve this goal: Firstly, the project is developing and optimizing algorithms for the retrieval of hourly aerosol optical depth (AOD) maps from the Spinning Enhanced Visible and InfraRed Imager (SEVIRI) onboard of Meteosat Second Generation. As a second activity, SAMIRA aims to derive particulate matter (PM2.5) estimates from AOD data by developing robust algorithms for AOD-to-PM conversion with the support from model- and Lidar data. In a third activity, we evaluate the added value of satellite products of atmospheric composition for operational European-scale air quality mapping using geostatistics and auxiliary datasets. The additional benefit of satellite-based monitoring over existing monitoring techniques (in situ, models) is tested by combining these datasets using geostatistical methods and demonstrated for nitrogen dioxide (NO2), sulphur dioxide (SO2), and aerosol optical depth/particulate matter. As a fourth activity, the project is developing novel algorithms for downscaling coarse-resolution satellite products of air quality with the help of high-resolution model information. This will add value to existing earth observation products of air quality by bringing them to spatial scales that are more in line with what is generally required for studying urban and regional scale air quality. In a fifth activity, we implement robust and independent validation schemes for evaluating the quality of the generated products. Finally, in a sixth activity the consortium is working towards a pre-operational system for improved PM forecasts using observational (in situ and satellite) data assimilation. SAMIRA aims to maximize project benefits by liaison with national and regional environmental protection agencies and health institutions, as well as related ESA and European initiatives such as the Copernicus Atmosphere Monitoring Service (CAMS).

  8. Lateralization of spatial information processing in response monitoring

    PubMed Central

    Stock, Ann-Kathrin; Beste, Christian

    2014-01-01

    The current study aims at identifying how lateralized multisensory spatial information processing affects response monitoring and action control. In a previous study, we investigated multimodal sensory integration in response monitoring processes using a Simon task. Behavioral and neurophysiologic results suggested that different aspects of response monitoring are asymmetrically and independently allocated to the hemispheres: while efference-copy-based information on the motor execution of the task is further processed in the hemisphere that originally generated the motor command, proprioception-based spatial information is processed in the hemisphere contralateral to the effector. Hence, crossing hands (entering a “foreign” spatial hemifield) yielded an augmented bilateral activation during response monitoring since these two kinds of information were processed in opposing hemispheres. Because the traditional Simon task does not provide the possibility to investigate which aspect of the spatial configuration leads to the observed hemispheric allocation, we introduced a new “double crossed” condition that allows for the dissociation of internal/physiological and external/physical influences on response monitoring processes. Comparing behavioral and neurophysiologic measures of this new condition to those of the traditional Simon task setup, we could demonstrate that the egocentric representation of the physiological effector's spatial location accounts for the observed lateralization of spatial information in action control. The finding that the location of the physical effector had a very small influence on response monitoring measures suggests that this aspect is either less important and/or processed in different brain areas than egocentric physiological information. PMID:24550855

  9. Calibration and validation of wearable monitors.

    PubMed

    Bassett, David R; Rowlands, Alex; Trost, Stewart G

    2012-01-01

    Wearable monitors are increasingly being used to objectively monitor physical activity in research studies within the field of exercise science. Calibration and validation of these devices are vital to obtaining accurate data. This article is aimed primarily at the physical activity measurement specialist, although the end user who is conducting studies with these devices also may benefit from knowing about this topic. Initially, wearable physical activity monitors should undergo unit calibration to ensure interinstrument reliability. The next step is to simultaneously collect both raw signal data (e.g., acceleration) from the wearable monitors and rates of energy expenditure, so that algorithms can be developed to convert the direct signals into energy expenditure. This process should use multiple wearable monitors and a large and diverse subject group and should include a wide range of physical activities commonly performed in daily life (from sedentary to vigorous). New methods of calibration now use "pattern recognition" approaches to train the algorithms on various activities, and they provide estimates of energy expenditure that are much better than those previously available with the single-regression approach. Once a method of predicting energy expenditure has been established, the next step is to examine its predictive accuracy by cross-validating it in other populations. In this article, we attempt to summarize the best practices for calibration and validation of wearable physical activity monitors. Finally, we conclude with some ideas for future research ideas that will move the field of physical activity measurement forward.

  10. Statistical Research of Investment Development of Russian Regions

    ERIC Educational Resources Information Center

    Burtseva, Tatiana A.; Aleshnikova, Vera I.; Dubovik, Mayya V.; Naidenkova, Ksenya V.; Kovalchuk, Nadezda B.; Repetskaya, Natalia V.; Kuzmina, Oksana G.; Surkov, Anton A.; Bershadskaya, Olga I.; Smirennikova, Anna V.

    2016-01-01

    This article the article is concerned with a substantiation of procedures ensuring the implementation of statistical research and monitoring of investment development of the Russian regions, which would be pertinent for modern development of the state statistics. The aim of the study is to develop the methodological framework in order to estimate…

  11. Technology Mediated Information Sharing (Monitor Sharing) in Primary Care Encounters

    ERIC Educational Resources Information Center

    Asan, Onur

    2013-01-01

    The aim of this dissertation study was to identify and describe the use of electronic health records (EHRs) for information sharing between patients and clinicians in primary-care encounters and to understand work system factors influencing information sharing. Ultimately, this will promote better design of EHR technologies and effective training…

  12. Using transcriptomic tools to evaluate biological effects across effluent gradients at a diverse set of study sites in Minnesota, USA

    EPA Science Inventory

    The aim of this overall project was to explore the utility of ?‘omics’ approaches in monitoring aquatic environments where complex, often unknown, stressors make chemical-specific risk assessment untenable. This specific component of the effort examined changes in the fathead min...

  13. 1982 Maths Investigation: Technical Report. Mt. Druitt Longitudinal Study.

    ERIC Educational Resources Information Center

    Houghton, Karen; Low, Brian

    Aims of this phase of a longitudinal mathematics achievement investigation were to (1) detect individual and group differences in math achievement among a sample of fourth-year children, (2) monitor changes in math skills since a 1981 math investigation, and (3) identify limits of children's understanding of mathematical concepts. (The math test…

  14. Distributed Leadership as Administrative Practice in Finnish Early Childhood Education and Care

    ERIC Educational Resources Information Center

    Kangas, Jonna; Venninen, Tuulikki; Ojala, Mikko

    2016-01-01

    In this article, we describe the professional development towards distributed leadership among different organizational levels in Finnish day care centres within the Helsinki metropolitan area. The aim of the study was to monitor the progress of professional development between educational administration and practitioners. The data was based on…

  15. Expressive Vocabulary Acquisition in Children with Intellectual Disability: Speech or Manual Signs?

    ERIC Educational Resources Information Center

    Vandereet, Joke; Maes, Bea; Lembrechts, Dirk; Zink, Inge

    2011-01-01

    Background: The aim of this study was to examine the degree to which children with intellectual disability (ID) depend on manual signs during their expressive vocabulary acquisition, in relation to child and social-environmental characteristics. Method: Expressive vocabulary acquisition in speech and manual signs was monitored over a 2-year period…

  16. Enhancing Teaching Effectiveness by Using the Six-Sigma DMAIC Model

    ERIC Educational Resources Information Center

    Yu, Kun-Tzu; Ueng, Ren-Gen

    2012-01-01

    As the competition increases in higher education, how to improve teaching quality to promote educational performance becomes a significant issue. Many higher educational institutions (HEIs) make efforts to establish a feedback system to monitor and reflect the outcomes of teaching evaluations. This study aimed to describe the use of the Six-Sigma…

  17. Development of a Metaconceptual Awareness and Regulation Scale

    ERIC Educational Resources Information Center

    Kirbulut, Zubeyde Demet; Uzuntiryaki-Kondakci, Esen; Beeth, Michael Edward

    2016-01-01

    This study aimed to develop the Metaconceptual Awareness and Regulation Scale (MARS) -- a self-report instrument for measuring the extent to which students realise, monitor, and evaluate their ideas. MARS consists of 10 items scored on a six-point Likert scale for two factors: metaconceptual awareness and metaconceptual regulation. A pilot study…

  18. Actigraphic Monitoring during Sleep of Children with ADHD on Methylphenidate and Placebo

    ERIC Educational Resources Information Center

    Schwartz, George; Amor, Leila Ben; Grizenko, Natalie; Lageix, Philippe; Baron, Chantal; Boivin, Diane B.; Joober, Ridha

    2004-01-01

    Objective: Sleep disturbances appear as a comorbid condition in children with attention-deficit/hyperactivity disorder. The aim of this study was to investigate the relationship of activity levels during sleep and therapeutic response to methylphenidate (MPH). Method: Nightly sleep actigraphic recordings during a double-blind, placebo-controlled,…

  19. Web-Based Analysis of Internationalization in Israeli Teaching Colleges

    ERIC Educational Resources Information Center

    Cohen, Anat; Yemini, Miri; Sadeh, Efrat

    2014-01-01

    The international activities of academic institutions dramatically expanded in volume, scope, and complexity during the past three decades. This expansion raised the need to monitor and assess the process at various levels and ensure the effectiveness and efficiency of internationalization. This study has two main aims: first, to present a model…

  20. The Coordinated Interplay of Scene, Utterance, and World Knowledge: Evidence from Eye Tracking

    ERIC Educational Resources Information Center

    Knoeferle, Pia; Crocker, Matthew W.

    2006-01-01

    Two studies investigated the interaction between utterance and scene processing by monitoring eye movements in agent-action-patient events, while participants listened to related utterances. The aim of Experiment 1 was to determine if and when depicted events are used for thematic role assignment and structural disambiguation of temporarily…

  1. A novel framework for the use of remote sensing for monitoring catchments at continental scales.

    PubMed

    Bugnot, A B; Lyons, M B; Scanes, P; Clark, G F; Fyfe, S K; Lewis, A; Johnston, E L

    2018-07-01

    Historical ecology can teach us valuable lessons on the processes and drivers of environmental change that can inform future monitoring priorities and management strategies. Environmental data to study environmental history, however, is often absent or of low quality. Even when studying changes occurring during the last few decades, monitoring efforts are scarce due to logistical and cost limitations, leaving large areas unassessed. The aim of this study is to evaluate the use of estuarine water colour as an indicator of historical environmental change in catchments. Water colour change was assessed in estuaries in Australia from 1987 to 2015 using satellite remote sensing. Random points were selected for each estuary and applied to the Australian Geoscience Data Cube (based on Landsat images) to obtain reflectance data through time. We propose a framework where (i) water colour is used to detect historical changes in catchments using generalised additive models, (ii) possible stressors and pressures driving those changes are evaluated using other available historical data, and (iii) lessons learned inform appropriate monitoring and management actions. This framework represents a novel approach to generate historical data for large-scale assessments of environmental change at catchment level, even in poorly studied areas. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  2. Fear, Rationality and Opportunity: Reasons and Motives for Not Trying Ecstasy

    ERIC Educational Resources Information Center

    Vervaeke, Hylke Karen Eva; Benschop, Annemieke; Korf, Dirk Jan

    2008-01-01

    Aim: To gain more insight into the reasons and motives why people do not start taking ecstasy. Method: As part of the NeXT Study, we prospectively monitored 188 subjects who were ecstasy-naive at baseline but seemed likely to take ecstasy (MDMA) of their own accord during the course of the study. After an 11- to 26-month follow-up period, 160…

  3. An Intervention to Increase the Use of Asthma Action Plans in Schools: A MASNRN Study

    ERIC Educational Resources Information Center

    Pulcini, Joyce; DeSisto, Marie C.; McIntyre, C. Lynne

    2007-01-01

    School nurses, in collaboration with primary care providers (PCPs), can work to better manage asthma by using the Asthma Action Plan (AAP) with peak flow monitoring. The aim of this pilot study was to determine the effectiveness of an intervention to increase the number of AAPs in schools for students with asthma by having school nurses provide…

  4. Blood pressure monitoring: theory and practice. European Society of Hypertension Working Group on Blood Pressure Monitoring and Cardiovascular Variability Teaching Course Proceedings.

    PubMed

    Stergiou, George S; Palatini, Paolo; Asmar, Roland; Bilo, Grzegorz; de la Sierra, Alejandro; Head, Geoff; Kario, Kazuomi; Mihailidou, Anastasia; Wang, Jiguang; Mancia, Giuseppe; O'Brien, Eoin; Parati, Gianfranco

    2018-02-01

    The European Society of Hypertension (ESH) Working Group on Blood Pressure (BP) Monitoring and Cardiovascular Variability organized a Teaching Course on 'Blood Pressure Monitoring: Theory and Practice' during the 2017 ESH Meeting in Milan, Italy. This course performed by 11 international BP monitoring experts covered key topics of BP monitoring, including office BP measurement, ambulatory BP monitoring, home BP monitoring, ambulatory versus home BP, white-coat and masked hypertension, cuff use, and BP variability. This article presents a summary of the proceedings of the ESH BP Monitoring Teaching Course, including essential information, practical issues, and recommendations on the clinical application of BP monitoring methods, aiming to the optimal management of patients with suspected or diagnosed hypertension.

  5. Is it me? Verbal self-monitoring neural network and clinical insight in schizophrenia.

    PubMed

    Sapara, Adegboyega; Ffytche, Dominic H; Cooke, Michael A; Williams, Steven C R; Kumari, Veena

    2015-12-30

    Self-monitoring, defined as the ability to distinguish between self-generated stimuli from other-generated ones, is known to be impaired in schizophrenia. This impairment has been theorised as the basis for many of the core psychotic symptoms, in particular, poor clinical insight. This study aimed to investigate verbal self-monitoring related neural substrates of preserved and poor clinical insight in schizophrenia. It involved 40 stable schizophrenia outpatients, 20 with preserved and 20 with poor insight, and 20 healthy participants. All participants underwent functional magnetic resonance imaging with brain coverage covering key areas in the self-monitoring network during a verbal self-monitoring task. Healthy participants showed higher performance accuracy and greater thalamic activity than both preserved and poor insight patient groups. Preserved insight patients showed higher activity in the putamen extending into the caudate, insula and inferior frontal gyrus, compared to poor insight patients, and in the anterior cingulate and medial frontal gyrus, compared to healthy participants. Poor insight patients did not show greater activity in any brain area compared to preserved insight patients or healthy participants. Future studies may pursue therapeutic avenues, such as meta-cognitive therapies to promote self-monitoring or targeted stimulation of relevant brain areas, as means of enhancing insight in schizophrenia. Copyright © 2015 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  6. Clinical validation of a medical grade color monitor for chest radiology

    NASA Astrophysics Data System (ADS)

    Jacobs, J.; Zanca, F.; Verschakelen, J.; Marchal, G.; Bosmans, H.

    2009-02-01

    Until recently, the specifications of medical grade monochrome LCD monitors outperformed those of color LCD monitors. New generations of color LCD monitors, however, show specifications that are in many respects similar to those of monochrome monitors typically used in diagnostic workstations. The aim of present study was to evaluate the impact of different medical grade monitors in terms of detection of simulated lung nodules in chest x-ray images. Specifically, we wanted to compare a new medical grade color monitor (Barco Coronis 6MP color) to a medical grade grayscale monitor (Barco Coronis 3MP monochrome) and a consumer color monitor (Philips 200VW 1.7MP color) by means of an observer performance experiment. Using the free-response acquisition data paradigm, seven radiologists were asked to detect and locate lung nodules (170 in total), simulated in half of the 200 chest X-ray images used in the experiment. The jackknife free-response receiver operating characteristic (JAFROC) analysis of the data showed a statistically significant difference between at least two monitors, F-value=3.77 and p-value =0.0481. The different Figure of Merit values were 0.727, 0.723 and 0.697 for the new color LCD monitor, the medical grade monitor and the consumer color monitor respectively. There was no difference between the needed reading times but there was a difference between the mean calculated Euclidian distances between the position marked by the observers and the center of the simulated nodule, indicating a better accuracy with both medical grade monitors. Present data suggests that the new generation of medical grade color monitors could be used as diagnostic workstations.

  7. National health inequality monitoring: current challenges and opportunities.

    PubMed

    Hosseinpoor, Ahmad Reza; Bergen, Nicole; Schlotheuber, Anne; Boerma, Ties

    National health inequality monitoring needs considerably more investment to realize equity-oriented health improvements in countries, including advancement towards the Sustainable Development Goals. Following an overview of national health inequality monitoring and the associated resource requirements, we highlight challenges that countries may encounter when setting up, expanding or strengthening national health inequality monitoring systems, and discuss opportunities and key initiatives that aim to address these challenges. We provide specific proposals on what is needed to ensure that national health inequality monitoring systems are harnessed to guide the reduction of health inequalities.

  8. Unified Monitoring Architecture for IT and Grid Services

    NASA Astrophysics Data System (ADS)

    Aimar, A.; Aguado Corman, A.; Andrade, P.; Belov, S.; Delgado Fernandez, J.; Garrido Bear, B.; Georgiou, M.; Karavakis, E.; Magnoni, L.; Rama Ballesteros, R.; Riahi, H.; Rodriguez Martinez, J.; Saiz, P.; Zolnai, D.

    2017-10-01

    This paper provides a detailed overview of the Unified Monitoring Architecture (UMA) that aims at merging the monitoring of the CERN IT data centres and the WLCG monitoring using common and widely-adopted open source technologies such as Flume, Elasticsearch, Hadoop, Spark, Kibana, Grafana and Zeppelin. It provides insights and details on the lessons learned, explaining the work performed in order to monitor the CERN IT data centres and the WLCG computing activities such as the job processing, data access and transfers, and the status of sites and services.

  9. Monitoring beach evolution using low-altitude aerial photogrammetry and UAV drones

    NASA Astrophysics Data System (ADS)

    Rovere, Alessio; Casella, Elisa; Vacchi, Matteo; Mucerino, Luigi; Pedroncini, Andrea; Ferrari, Marco; Firpo, Marco

    2014-05-01

    Beach monitoring is essential in order to understand the mechanisms of evolution of soft coasts, and the rates of erosion. Traditional beach monitoring techniques involve topographic and bathymetric surveys of the beach, and/or aerial photos repeated in time and compared through geographical information systems. A major problem of this kind of approach is the high economic cost. This often leads to increase the time lag between successive monitoring campaigns to reduce survey costs, with the consequence of fragmenting the information available for coastal zone management. MIRAMar is a project funded by Regione Liguria through the PO CRO European Social Fund, and has two main objectives: i) to study and develop an innovative technique, relatively low-cost, to monitor the evolution of the shoreline using low-altitude Unmanned Aerial Vehicle (UAV) photogrammetry; ii) to study the impact of different type of storm events on a vulnerable coastal tract subject to coastal erosion using also the data collected by the UAV instrument. To achieve these aims we use a drone with its hardware and software suit, traditional survey techniques (bathymetric surveys, topographic GPS surveys and GIS techniques) and we implement a numerical modeling chain (coupling hydrodynamic, wave and sand transport modules) in order to study the impact of different type of storm events on a vulnerable coastal tract subject to coastal erosion.

  10. Hydrogeochemical investigation to understand nitrate movement in groundwater of volcanic island, Korea

    NASA Astrophysics Data System (ADS)

    Kwon, E. H.; Park, J.; Chung, E.; Kang, B. R.; Park, W. B.; Woo, N. C.

    2017-12-01

    Groundwater is the sole-source of water supply in the volcanic island, Jeju-do, Korea. Since early 1990s, the nitrate contamination of groundwater has increased especially in the western part of the island. High level of nitrate in water can cause not only health risk to human body but also environmental side effect such as eutrophication and algal bloom in the coastal area. Several studies have done to estimate nitrate contamination in groundwater of local areas, but none of them dealt with nitrate movement with flow paths. So, this study aimed to determine the source and migration of nitrate in groundwater in the Gosan area, located in the western part of Jeju island through seasonal monitoring of hydrogeochemistry and stable isotope analyses from pumping and monitoring wells. Water samples including rainfall and groundwater are measured for major ions (Ca, Na, K, Mg, SO4, HCO3, NO3, Cl, etc.) and stable isotopes (i.e., δ2H, δ18O, δ18O-NO3, δ15N-NO3). From the monitoring data, we could evaluate hydrochemical change during nitrate contamination, and also could identify that groundwater in Gosan area is recharged mainly by regional flow from the high-altitude region. In future study, we will conduct additional seasonal monitoring from the multi-depth monitoring wells and will use statistical analysis to understand pollution sources and paths specifically.

  11. Safer laparoscopic trocar entry: it's all about pressure.

    PubMed

    Tsaltas, Jim; Pearce, Scott; Lawrence, Anthony; Meads, Alan; Mezzatesta, Joseph; Nicolson, Scott

    2004-08-01

    This prospective observational study aimed to assess the feasibility of adapting peritoneal hyperdistention to 25 mmHg during laparoscopy in an Australian hospital environment. A total of 1150 consecutive diagnostic or operative laparoscopies were performed. All cases were monitored for early detection of untoward physiological changes. All patients had Veress needle insufflation with distension to 25 mmHg prior to insertion of the primary trocar. No patients experienced any surgical entry complications or adverse clinical effects noted during anaesthetic. The aim of the current study is to assess the feasibility and safety of increasing the peritoneal insufflation pressure to 25 mmHg for primary trocar insertion.

  12. Recommendations for standardizing validation procedures assessing physical activity of older persons by monitoring body postures and movements.

    PubMed

    Lindemann, Ulrich; Zijlstra, Wiebren; Aminian, Kamiar; Chastin, Sebastien F M; de Bruin, Eling D; Helbostad, Jorunn L; Bussmann, Johannes B J

    2014-01-10

    Physical activity is an important determinant of health and well-being in older persons and contributes to their social participation and quality of life. Hence, assessment tools are needed to study this physical activity in free-living conditions. Wearable motion sensing technology is used to assess physical activity. However, there is a lack of harmonisation of validation protocols and applied statistics, which make it hard to compare available and future studies. Therefore, the aim of this paper is to formulate recommendations for assessing the validity of sensor-based activity monitoring in older persons with focus on the measurement of body postures and movements. Validation studies of body-worn devices providing parameters on body postures and movements were identified and summarized and an extensive inter-active process between authors resulted in recommendations about: information on the assessed persons, the technical system, and the analysis of relevant parameters of physical activity, based on a standardized and semi-structured protocol. The recommended protocols can be regarded as a first attempt to standardize validity studies in the area of monitoring physical activity.

  13. Technologies for physical activity self-monitoring: a study of differences between users and non-users

    PubMed Central

    Åkerberg, Anna; Söderlund, Anne; Lindén, Maria

    2017-01-01

    Background Different kinds of physical activity (PA) self-monitoring technologies are used today to monitor and motivate PA behavior change. The user focus is essential in the development process of this technology, including potential future users such as representatives from the group of non-users. There is also a need to study whether there are differences between the groups of users and non-users. The aims of this study were to investigate possible differences between users and non-users regarding their opinions about PA self-monitoring technologies and to investigate differences in demographic variables between the groups. Materials and methods Participants were randomly selected from seven municipalities in central Sweden. In total, 107 adults responded to the Physical Activity Products Questionnaire, which consisted of 22 questions. Results Significant differences between the users and non-users were shown for six of the 20 measurement-related items: measures accurately (p=0.007), measures with high precision (p=0.024), measures distance (p=0.020), measures speed (p=0.003), shows minutes of activity (p=0.004), and shows geographical position (p=0.000). Significant differences between the users and non-users were also found for two of the 29 encouragement items: measures accurately (p=0.001) and has long-term memory (p=0.019). Significant differences between the groups were also shown for level of education (p=0.030) and level of physical exercise (p=0.037). Conclusion With a few exceptions, the users and the non-users in this study had similar opinions about PA self-monitoring technologies. Because this study showed significant differences regarding level of education and level of physical exercise, these demographic variables seemed more relevant to investigate than differences in opinions about the PA self-monitoring technologies. PMID:28280399

  14. Long-term monitoring of diversity and structure of two stands of an Atlantic Tropical Forest

    PubMed Central

    Carvalho, Warley Augusto Caldas; Santos, Rubens Manoel; Gastauer, Markus; Garcia, Paulo Oswaldo; Fontes, Marco Aurélio Leite; Coelho, Polyanne Aparecida; Moreira, Aline Martins; Menino, Gisele Cristina Oliveira; Oliveira-Filho, Ary Teixeira

    2017-01-01

    Abstract Background This study aimed to report the long-term monitoring of diversity and structure of the tree community in a protected semideciduous Atlantic Forest in the South of Minas Gerais State, Southeast Brazil. The study was conducted in two stands (B and C), each with 26 and 38 10 m x 30 m plots. Censuses of stand B were conducted in 2000, 2005 and 2011, and stand C in 2001, 2006 and 2011. In both stands, the most abundant and important species for biomass accumulation over the inventories were trees larger than 20 cm of diameter, which characterize advanced successional stage within the forest. New information The two surveyed stands within the studied forest presented differences in structure, diversity and species richness over the time. PMID:28848371

  15. Venus Monitoring Camera (VMC/VEx) 1 micron emissivity and Magellan microwave properties of crater-related radar-dark parabolas and other terrains

    NASA Astrophysics Data System (ADS)

    Basilevsky, A. T.; Shalygina, O. S.; Bondarenko, N. V.; Shalygin, E. V.; Markiewicz, W. J.

    2017-09-01

    The aim of this work is a comparative study of several typical radar-dark parabolas, the neighboring plains and some other geologic units seen in the study areas which include craters Adivar, Bassi, Bathsheba, du Chatelet and Sitwell, at two depths scales: the upper several meters of the study object available through the Magellan-based microwave (at 12.6 cm wavelength) properties (microwave emissivity, Fresnel reflectivity, large-scale surface roughness, and radar cross-section), and the upper hundreds microns of the object characterized by the 1 micron emissivity resulted from the analysis of the near infra-red (NIR) irradiation of the night-side of the Venusian surface measured by the Venus Monitoring Camera (VMC) on-board of Venus Express (VEx).

  16. Long-term monitoring of diversity and structure of two stands of an Atlantic Tropical Forest.

    PubMed

    Diniz, Écio Souza; Carvalho, Warley Augusto Caldas; Santos, Rubens Manoel; Gastauer, Markus; Garcia, Paulo Oswaldo; Fontes, Marco Aurélio Leite; Coelho, Polyanne Aparecida; Moreira, Aline Martins; Menino, Gisele Cristina Oliveira; Oliveira-Filho, Ary Teixeira

    2017-01-01

    This study aimed to report the long-term monitoring of diversity and structure of the tree community in a protected semideciduous Atlantic Forest in the South of Minas Gerais State, Southeast Brazil. The study was conducted in two stands (B and C), each with 26 and 38 10 m x 30 m plots. Censuses of stand B were conducted in 2000, 2005 and 2011, and stand C in 2001, 2006 and 2011. In both stands, the most abundant and important species for biomass accumulation over the inventories were trees larger than 20 cm of diameter, which characterize advanced successional stage within the forest. The two surveyed stands within the studied forest presented differences in structure, diversity and species richness over the time.

  17. Exploring the Potential of PROBA-V for Evapotranspiration Monitoring in Wetlands

    NASA Astrophysics Data System (ADS)

    Barrios, Jose Miguel; Ghilain, Nicolas; Arboleda, Alirio; Gellens-Meulenberghs, Francoise

    2016-08-01

    This study aims at deriving daily evapotranspiration (ET) estimates at a convenient spatial resolution for ecosystem monitoring. The methodological approach was based on the computation of the energy balance over the study sites. The study explored the potential of integrating remote sensing (RS) products derived from the Meteosat Second Generation (MSG) satellite -in virtue of their high temporal resolution- and Proba-V data, supplying moderate spatial resolution data. This strategy was tested for the year 2014 on three wetlands sites located in Europe where eddy covariance measurements were available for validation. The modelled results correlated well with the validation data and showed the added value of combining the strengths of different satellite missions. The results open interesting perspectives for refining this approach with the upcoming Sentinel-3 datasets.

  18. Measuring Progress Toward Universal Health Coverage: Does the Monitoring Framework of Bangladesh Need Further Improvement?

    PubMed Central

    Shahabuddin, ASM

    2018-01-01

    This review aimed to compare Bangladesh’s Universal Health Coverage (UHC) monitoring framework with the global-level recommendations and to find out the existing gaps of Bangladesh’s UHC monitoring framework compared to the global recommendations. In order to reach the aims of the review, we systematically searched two electronic databases - PubMed and Google Scholar - by using appropriate keywords to select articles that describe issues related to UHC and the monitoring framework of UHC applied globally and particularly in Bangladesh. Four relevant documents were found and synthesized. The review found that Bangladesh incorporated all of the recommendations suggested by the global monitoring framework regarding mentoring the financial risk protection and equity perspective. However, a significant gap in the monitoring framework related to service coverage was observed. Although Bangladesh has a significant burden of mental illnesses, cataract, and neglected tropical diseases, indicators related to these issues were absent in Bangladesh’s UHC framework. Moreover, palliative-care-related indicators were completely missing in the framework. The results of this review suggest that Bangladesh should incorporate these indicators in their UHC monitoring framework in order to track the progress of the country toward UHC more efficiently and in a robust way. PMID:29541562

  19. Ultrasonic guided wave for monitoring corrosion of steel bar

    NASA Astrophysics Data System (ADS)

    Liu, Xi; Qin, Lei; Huang, Bosheng

    2018-01-01

    Steel corrosion of reinforced concrete structures has become a serious problem all over the word. In this paper, the work aims at monitoring steel corrosion using ultrasonic guided wave (UGW). Ultrasonic guided wave monitoring is a dynamic and non-destructive testing technology. The advantages of ultrasonic guided wave monitoring for reinforcement corrosion are real-time, online and continuous. In addition, it can judge the different stages of steel bar corrosion, which achieved non-destructive detection.

  20. [The Effect of Intraoperative Screw Monitoring (Root Monitoring) with the INS-1 System (NUVASIVE) on the Radiological Outcome of Dorsal Instrumentation of the Lumbar Spine].

    PubMed

    Bernhardt, G; Awiszus, F; Meister, U; Heyde, C E; Böhm, H

    2016-06-01

    Transpedicular screw fixation of spinal segments has been described for a variety of surgical indications and is a key element in spinal surgery. The aim of transpedicular screw fixation is to achieve maximal stability. Screw malposition should be obviated to avoid neurological complications. There are published methods of applying evoked EMG to control screw position in relation to neural structures. These studies demonstrated that an intact bony pedicle wall acts as an electrical isolator between the screw and spinal nerve root. The aim of our study was to evaluate the impact of intraoperative pedicle screw monitoring on screw positioning. We enrolled 22 patients in this prospective randomised study, who underwent spinal instrumentation after being split into two equal groups. In the first group, dorsal instrumentation was supplemented with intraoperative nerve root monitoring using the INS-1-System (NuVasive, San Diego USA). In the second group, screws were inserted without additional pedicle monitoring. All patients underwent monosegmental instrumentation with "free hand implanted" pedicle screws. 44 screws were inserted in each group. The screw position was evaluated postoperatively using CT scans. The position of the screws in relation to the pedicle was measured in three different planes: sagittal, axial and coronal. The accuracy of the screw position was described using the Berlemann classification system. Screw position is classified in three groups: type 1 correct screw position, type 2 encroachment on the inner cortical wall, type 3 pedicle cortical perforation. Screw angulation and secondary operative criteria were also evaluated. The use of neuromonitoring did not influence the distance between the centre of the screws and the pedicle wall. Distances only depended on the implantation side (right and left) and the height of implantation (caudal or cranial screw). Because of the low number of cases, no conclusion could be reached about the influence of root monitoring on the correct positioning of the screws. There was at least a non-significant trend towards more frequent perforation of the pedicle in the monitor group. In the present study, we showed that root monitoring had a significant effect on the scattering of transversal angles. These were increased compared to the control group. Otherwise, the implantation angle was not shown to depend on the use of neuromonitoring. Neuromonitoring did not influence blood loss or operative time. The data did not permit any conclusion as to whether this technique can minimise the frequency of pedicle screw malposition. The four coronal plane distances did not depend on the use of neuromonitoring. The inclination angle was also unaffected by neuromonitoring. The only parameter for which we found any effect was the transverse angle. The mean values were similar in both groups, but the variances were not equal. The effect of monitoring on the only parameter which could not be evaluated by fluoroscopy is thus rather unfavourable. Georg Thieme Verlag KG Stuttgart · New York.

  1. GB-InSAR monitoring and observational method for landslide emergency management: the Montaguto earthflow (AV, Italy)

    NASA Astrophysics Data System (ADS)

    Ferrigno, Federica; Gigli, Giovanni; Fanti, Riccardo; Intrieri, Emanuele; Casagli, Nicola

    2017-06-01

    On 10 March 2010, because of the heavy rainfall in the preceding days, the Montaguto landslide (Southern Italy) reactivated, affecting both state road 90 Delle Puglie and the Rome-Bari railway. A similar event occurred on May 2005 and on September 2009. As a result, the National Civil Protection Department (DPC) started an accurate monitoring and analysis program. A monitoring project using the GB-InSAR (ground-based interferometric synthetic aperture radar) system was emplaced to investigate the landslide kinematics, plan urgent safety measures for risk mitigation and design long-term stabilization work.Here, we present the GB-InSAR monitoring system results and its applications in the observational method (OM) approach. GB-InSAR is an established instrument for long-term campaigns aimed at early warning and monitoring during construction works. Our paper further develops these aspects in that it highlights how the OM based on the GB-InSAR technique can produce savings in terms of cost and time in engineering projects without compromising safety. This study focuses on the key role played by the monitoring activities during the design and planning activities, with special reference to the emergency phase.

  2. C-B3-03: Development and Pilot Testing of Guidelines to Monitor High-Risk Medications in the Ambulatory Setting

    PubMed Central

    Tjia, Jennifer; Field, Terry; Garber, Lawrence; Raebel, Marsha; Donovan, Jennifer; Kanaan, Abir; Fischer, Shira; Gagne, Shawn; Zhao, Yanfang; Fuller, Jackie; Gurwitz, Jerry

    2010-01-01

    Background: Inadequate laboratory monitoring of high-risk medications contributes to preventable adverse drug events. One barrier to appropriate monitoring is lack of standardized monitoring guidelines. The study aims were to develop guidelines to monitor high-risk medications and to assess the prevalence of laboratory testing for these medications in a multispecialty group practice. Methods: We developed guidelines for laboratory monitoring of high-risk medications as part of a patient safety intervention trial. An advisory committee of national experts and local leaders (clinicians, pharmacists, pharmacoepidemiologists, and patient safety experts) used a two-round, internet-based Delphi process to select guideline medications based on the importance of monitoring for efficacy, safety, and drug-drug interactions. Test frequency recommendations were developed by academic pharmacists based on literature review and local interdisciplinary consensus. To estimate the potential impact of the intervention, we determined the prevalence of high-risk drug dispensings and laboratory testing for guideline medications between January 1, 2008 and July 31, 2008. Results: Consensus on medications to include in the guidelines was achieved in two rounds. Final guidelines included 35 drugs/drug classes and 61 laboratory tests. The prevalence of monitoring ranged from <50% to >90%, with infrequently prescribed drugs having a lower prevalence of recommended testing. When more than one test was recommended for a selected medication, monitoring within a medication sometimes differed by > 50%. Conclusions: Even among drugs where there is general consensus that laboratory monitoring is important, prevalence of monitoring is highly variable. Further, infrequently prescribed medications are at higher risk for poor monitoring.

  3. A review of protocols for monitoring streams and juvenile fish in forested regions of the Pacific Northwest.

    Treesearch

    Scott A. Stolnack; Mason D. Bryant; Robert C. Wissmar

    2005-01-01

    This document reviews existing and proposed protocols used to monitor stream ecosystem conditions and responses to land management activities in the Pacific Northwest. Because of recent work aimed at improving the utility of habitat survey and fish abundance assessment methods, this review focuses on current (since 1993) monitoring efforts that assess stream habitat...

  4. Model-based monitoring of stormwater runoff quality.

    PubMed

    Birch, Heidi; Vezzaro, Luca; Mikkelsen, Peter Steen

    2013-01-01

    Monitoring of micropollutants (MP) in stormwater is essential to evaluate the impacts of stormwater on the receiving aquatic environment. The aim of this study was to investigate how different strategies for monitoring of stormwater quality (combining a model with field sampling) affect the information obtained about MP discharged from the monitored system. A dynamic stormwater quality model was calibrated using MP data collected by automatic volume-proportional sampling and passive sampling in a storm drainage system on the outskirts of Copenhagen (Denmark) and a 10-year rain series was used to find annual average (AA) and maximum event mean concentrations. Use of this model reduced the uncertainty of predicted AA concentrations compared to a simple stochastic method based solely on data. The predicted AA concentration, obtained by using passive sampler measurements (1 month installation) for calibration of the model, resulted in the same predicted level but with narrower model prediction bounds than by using volume-proportional samples for calibration. This shows that passive sampling allows for a better exploitation of the resources allocated for stormwater quality monitoring.

  5. Environmental performance, profitability, asset utilization, debt monitoring and firm value

    NASA Astrophysics Data System (ADS)

    Bukit, R. Br; Haryanto, B.; Ginting, P.

    2018-02-01

    The growing issue on firm value shows that firm value is not only determined by the firm ability to increase financial profit, but also by the company's concern in maintaining the environmental condition. The industrial development produces waste that pollutes the environment that has potential to serious impact on the next life. In addition to provide financial benefits, companies are increasingly facing pressure to be socially responsible for the survival of the company. However, past findings demonstrate that the effect of environmental performance, profitability, and asset utilization to the firm’s value are still unclear. This study aims to test whether environmental performance, firm profitability and asset utilization can effectively enhance firm value in two different conditions: intensive debt monitoring and less intensive debt monitoring. Sample of companies is taken from the list of Indonesia Stock Exchange during the period of 2013 to 2015. Using multiple regression analysis, discloses that: in intensive monitoring, managers tend to have high firm value when company has high environmental performance and or high profitability and high asset utilization. Monitoring system needs to be intensified especially for companies with the above characteristics.

  6. Uterine activity monitoring during labour--a multi-centre, blinded two-way trial of external tocodynamometry against electrohysterography.

    PubMed

    Reinhard, J; Hayes-Gill, B R; Schiermeier, S; Löser, H; Niedballa, L M; Haarmann, E; Sonnwald, A; Hatzmann, W; Heinrich, T M; Louwen, F

    2011-10-01

    The aim of this study was to determine the quality of intrapartum uterine activity (UA) monitoring in daily practice during the first and second stages of labour. The total duration of inadequate UA monitoring is quantified in relation to the technique applied, namely, external tocodynamometry (TOCO) or electrohysterography (EHG). 144 UA recordings, collected from 1st September 2008 until 15th October 2009 from deliveries at the Marien-Hospital Witten, Germany, were analysed by obstetricians based at different centres. The included recordings were from singleton and simultaneously with external TOCO and EHG monitored pregnancies. External TOCO and EHG UA recordings were blinded. The percentages of "adequate" UA recordings in the first and second stages of labour were much higher for the external EHG than the external TOCO mode (p<0.001). All doctors evaluated the UA assessment as "easier" (p <0.001) using the EHG compared with TOCO. Intrapartum UA monitoring in -daily practice via the EHG mode provides a more recognisable UA trace than the TOCO. © Georg Thieme Verlag KG Stuttgart · New York.

  7. The challenges of remote monitoring of wetlands

    USGS Publications Warehouse

    Gallant, Alisa L.

    2015-01-01

    Wetlands are highly productive and support a wide variety of ecosystem goods and services. Various forms of global change impose compelling needs for timely and reliable information on the status of wetlands worldwide, but several characteristics of wetlands make them challenging to monitor remotely: they lack a single, unifying land-cover feature; they tend to be highly dynamic and their energy signatures are constantly changing; and steep environmental gradients in and around wetlands produce narrow ecotones that often are below the resolving capacity of remote sensors. These challenges and needs set the context for a special issue focused on wetland remote sensing. Contributed papers responded to one of three overarching questions aimed at improving remote, large-area monitoring of wetlands: (1) What approaches and data products are being developed specifically to support regional to global long-term monitoring of wetland landscapes? (2) What are the promising new technologies and sensor/multisensor approaches for more accurate and consistent detection of wetlands? (3) Are there studies that demonstrate how remote long-term monitoring of wetland landscapes can reveal changes that correspond with changes in land cover and land use and/or changes in climate?

  8. Enabling end-user network monitoring via the multicast consolidated proxy monitor

    NASA Astrophysics Data System (ADS)

    Kanwar, Anshuman; Almeroth, Kevin C.; Bhattacharyya, Supratik; Davy, Matthew

    2001-07-01

    The debugging of problems in IP multicast networks relies heavily on an eclectic set of stand-alone tools. These tools traditionally neither provide a consistent interface nor do they generate readily interpretable results. We propose the ``Multicast Consolidated Proxy Monitor''(MCPM), an integrated system for collecting, analyzing and presenting multicast monitoring results to both the end user and the network operator at the user's Internet Service Provider (ISP). The MCPM accesses network state information not normally visible to end users and acts as a proxy for disseminating this information. Functionally, through this architecture, we aim to a) provide a view of the multicast network at varying levels of granularity, b) provide end users with a limited ability to query the multicast infrastructure in real time, and c) protect the infrastructure from overwhelming amount of monitoring load through load control. Operationally, our scheme allows scaling to the ISPs dimensions, adaptability to new protocols (introduced as multicast evolves), threshold detection for crucial parameters and an access controlled, customizable interface design. Although the multicast scenario is used to illustrate the benefits of consolidated monitoring, the ultimate aim is to scale the scheme to unicast IP networks.

  9. Lower Columbia River and Estuary Habitat Monitoring Study, 2011 - Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Borde, Amy B.; Kaufmann, Ronald M.; Cullinan, Valerie I.

    The Ecosystem Monitoring Program is a collaborative effort between the Lower Columbia River Estuary Partnership (LCREP), University of Washington, Wetland Ecosystem Team (UW), US Geological Survey, Water Science Center (USGS), National Oceanic and Atmospheric Administration, National Marine Fisheries Service (NOAA-Fisheries, hereafter NOAA), and Pacific Northwest National Laboratory, Marine Sciences Laboratory (PNNL). The goal of the program is to conduct emergent wetland monitoring aimed at characterizing salmonid habitats in the lower Columbia River and estuary (LCRE) from the mouth of the estuary to Bonneville Dam (Figure 1). This is an ecosystem based monitoring program focused on evaluating status and trends inmore » habitat and reducing uncertainties regarding these ecosystems to ultimately improve the survival of juvenile salmonids through the LCRE. This project comprehensively assesses habitat, fish, food web, and abiotic conditions in the lower river, focusing on shallow water and vegetated habitats used by juvenile salmonids for feeding, rearing and refugia. The information is intended to be used to guide management actions associated with species recovery, particularly that of threatened and endangered salmonids. PNNL’s role in this multi-year study is to monitor the habitat structure (e.g., vegetation, topography, channel morphology, and sediment type) as well as hydrologic patterns.« less

  10. Field-lysimeter and Column Studies As Complementary Survey Tools For Monitored Natural Attenuation (mna)

    NASA Astrophysics Data System (ADS)

    Totsche, K. U.; Hensel, D.; Jann, S.; Jaesche, P.; Kögel-Knabner, I.; Scheibke, R.

    The contamination of the unsaturated soil zone with organic pollutants (PAH, BTEX, PCB, Phenols, etc.) and pollutant mixtures, e.g. light/dense non-aqueous phase liq- uids (L/D-NAPLs), represents a specific challenge for sanitation and remediation of contaminated sites. Monitored natural attenuation as an alternative option for remedi- ation of such sites requires (1) the proof of an effective pollutant reduction potential and (2) the proof that a further spreading of the contaminants and their potentially toxic metabolites is minimized to an acceptable minimum concentration level. These demands apply equally likely to contaminated soil and groundwater environments. However, a major problem arises when the task is to monitor the release and transport of contaminants within the unsaturated soil zone over a longer period (> 10 years) of time at an expenditure as small as possible. The aim of our presentation is to employ and test a survey technique to monitor pollutant release and redistribution within the unsaturated soil zone in the context of MNA. The proposed technique is based on the combination of laboratory-column and field-lysimeter studies. The first is used to ac- quire knowledge on the governing processes, the latter is used to monitor release and transport of the contaminants.

  11. Non-invasive monitoring of reproductive and stress hormones in the endangered red panda (Ailurus fulgens fulgens).

    PubMed

    Beaulah Budithi, Neema Raja; Kumar, Vinod; Yalla, Suneel Kumar; Rai, Upashna; Umapathy, Govindhaswamy

    2016-09-01

    The red panda (Ailurus fulgens fulgens) is classified as endangered due to its declining population, habitat fragmentation and poaching. Efforts are being made to breed them in captivity as part of nationwide conservation breeding program. This study aimed to standardize Enzyme immunoassays (EIAs) to monitor reproductive (Progesterone metabolite, Testosterone) and stress hormone (Cortisol) in red panda. For this purpose, we collected 1471 faecal samples from four females and one male over a period of one year from Padmaja Naidu Himalayan Zoological Park, Darjeeling, India. HPLC confirmed the presence of immunoreactive 5α-pregnan-3α-ol-20-one, testosterone and cortisol metabolites in faecal samples. Using 5α-pregnan-3α-ol-20-one EIA, we were able to monitor reproduction and detect pregnancy in one of the females, which successfully conceived and delivered during the study period. We were also able to monitor testosterone and cortisol in faecal samples of the red panda. Faecal testosterone levels were found in higher concentration in breeding season than in non-breeding season. Faecal cortisol concentrations showed a negative relationship with ambient temperature and peaked during winter months in all animals. Standardization of EIAs and faecal hormone monitoring would facilitate red panda conservation breeding programs in India and elsewhere. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Microprocessor controlled compliance monitor for eye drop medication

    PubMed Central

    Hermann, M M; Diestelhorst, M

    2006-01-01

    Background/aims The effectiveness of a self administered eye drop medication can only be assessed if the compliance is known. The authors studied the specificity and sensitivity of a new microprocessor controlled monitoring device. Methods The monitoring system was conducted by an 8 bit microcontroller for data acquisition and storage with sensors measuring applied pressure to the bottle, temperature, and vertical position. 10 devices were mounted under commercial 10 ml eye drops. Test subjects had to note down each application manually. A total of 15 applications each within 3 days was intended. Results Manual reports confirmed 15 applications for each of the 10 bottles. The monitoring devices detected a total of 149 events; one was missed; comprising a sensitivity of 99%. Two devices registered three applications, which did not appear in the manual protocols, indicating a specificity of about 98%. Refrigerated bottles were correctly identified. The battery lifetime exceeded 60 days. Conclusion The new monitoring device demonstrated a high reliability of the collected compliance data. The important, yet often unknown, influence of compliance in patient care and clinical trials shall be illuminated by the new device. This may lead to a better adapted patient care. Studies will profit from a higher credibility and results will be less influenced by non‐compliance. PMID:16540488

  13. Blood pressure self-monitoring in pregnancy (BuMP) feasibility study; a qualitative analysis of women's experiences of self-monitoring.

    PubMed

    Hinton, Lisa; Tucker, Katherine L; Greenfield, Sheila M; Hodgkinson, James A; Mackillop, Lucy; McCourt, Christine; Carver, Trisha; Crawford, Carole; Glogowska, Margaret; Locock, Louise; Selwood, Mary; Taylor, Kathryn S; McManus, Richard J

    2017-12-19

    Hypertensive disorders in pregnancy are a leading cause of maternal and fetal morbidity worldwide. Raised blood pressure (BP) affects 10% of pregnancies worldwide, of which almost half develop pre-eclampsia. The proportion of pregnant women who have risk factors for pre-eclampsia (such as pre-existing hypertension, obesity and advanced maternal age) is increasing. Pre-eclampsia can manifest itself before women experience symptoms and can develop between antenatal visits. Incentives to improve early detection of gestational hypertensive disorders are therefore strong and self-monitoring of blood pressure (SMBP) in pregnancy might be one means to achieve this, whilst improving women's involvement in antenatal care. The Blood Pressure Self-Monitoring in Pregnancy (BuMP) study aimed to evaluate the feasibility and acceptability of SMBP in pregnancy. To understand women's experiences of SMBP during pregnancy, we undertook a qualitative study embedded within the BuMP observational feasibility study. Women who were at higher risk of developing hypertension and/or pre-eclampsia were invited to take part in a study using SMBP and also invited to take part in an interview. Semi-structured interviews were conducted at the women's homes in Oxfordshire and Birmingham with women who were self-monitoring their BP as part of the BuMP feasibility study in 2014. Interviews were conducted by a qualitative researcher and transcribed verbatim. A framework approach was used for analysis. Fifteen women agreed to be interviewed. Respondents reported general willingness to engage with monitoring their own BP, feeling that it could reduce anxiety around their health during pregnancy, particularly if they had previous experience of raised BP or pre-eclampsia. They felt able to incorporate self-monitoring into their weekly routines, although this was harder post-partum. Self-monitoring of BP made them more aware of the risks of hypertension and pre-eclampsia in pregnancy. Feelings of reassurance and empowerment were commonly reported by the women in our sample. SMBP in pregnancy was both acceptable and feasible to women in this small pilot study.

  14. Neonatal non-contact respiratory monitoring based on real-time infrared thermography

    PubMed Central

    2011-01-01

    Background Monitoring of vital parameters is an important topic in neonatal daily care. Progress in computational intelligence and medical sensors has facilitated the development of smart bedside monitors that can integrate multiple parameters into a single monitoring system. This paper describes non-contact monitoring of neonatal vital signals based on infrared thermography as a new biomedical engineering application. One signal of clinical interest is the spontaneous respiration rate of the neonate. It will be shown that the respiration rate of neonates can be monitored based on analysis of the anterior naris (nostrils) temperature profile associated with the inspiration and expiration phases successively. Objective The aim of this study is to develop and investigate a new non-contact respiration monitoring modality for neonatal intensive care unit (NICU) using infrared thermography imaging. This development includes subsequent image processing (region of interest (ROI) detection) and optimization. Moreover, it includes further optimization of this non-contact respiration monitoring to be considered as physiological measurement inside NICU wards. Results Continuous wavelet transformation based on Debauches wavelet function was applied to detect the breathing signal within an image stream. Respiration was successfully monitored based on a 0.3°C to 0.5°C temperature difference between the inspiration and expiration phases. Conclusions Although this method has been applied to adults before, this is the first time it was used in a newborn infant population inside the neonatal intensive care unit (NICU). The promising results suggest to include this technology into advanced NICU monitors. PMID:22243660

  15. INFORMAS (International Network for Food and Obesity/non-communicable diseases Research, Monitoring and Action Support): overview and key principles.

    PubMed

    Swinburn, B; Sacks, G; Vandevijvere, S; Kumanyika, S; Lobstein, T; Neal, B; Barquera, S; Friel, S; Hawkes, C; Kelly, B; L'abbé, M; Lee, A; Ma, J; Macmullan, J; Mohan, S; Monteiro, C; Rayner, M; Sanders, D; Snowdon, W; Walker, C

    2013-10-01

    Non-communicable diseases (NCDs) dominate disease burdens globally and poor nutrition increasingly contributes to this global burden. Comprehensive monitoring of food environments, and evaluation of the impact of public and private sector policies on food environments is needed to strengthen accountability systems to reduce NCDs. The International Network for Food and Obesity/NCDs Research, Monitoring and Action Support (INFORMAS) is a global network of public-interest organizations and researchers that aims to monitor, benchmark and support public and private sector actions to create healthy food environments and reduce obesity, NCDs and their related inequalities. The INFORMAS framework includes two 'process' modules, that monitor the policies and actions of the public and private sectors, seven 'impact' modules that monitor the key characteristics of food environments and three 'outcome' modules that monitor dietary quality, risk factors and NCD morbidity and mortality. Monitoring frameworks and indicators have been developed for 10 modules to provide consistency, but allowing for stepwise approaches ('minimal', 'expanded', 'optimal') to data collection and analysis. INFORMAS data will enable benchmarking of food environments between countries, and monitoring of progress over time within countries. Through monitoring and benchmarking, INFORMAS will strengthen the accountability systems needed to help reduce the burden of obesity, NCDs and their related inequalities. © 2013 The Authors. Obesity Reviews published by John Wiley & Sons Ltd on behalf of the International Association for the Study of Obesity.

  16. Fluid status monitoring with a wireless network to reduce cardiovascular-related hospitalizations and mortality in heart failure: rationale and design of the OptiLink HF Study (Optimization of Heart Failure Management using OptiVol Fluid Status Monitoring and CareLink)

    PubMed Central

    Brachmann, Johannes; Böhm, Michael; Rybak, Karin; Klein, Gunnar; Butter, Christian; Klemm, Hanno; Schomburg, Rolf; Siebermair, Johannes; Israel, Carsten; Sinha, Anil-Martin; Drexler, Helmut

    2011-01-01

    Aims The Optimization of Heart Failure Management using OptiVol Fluid Status Monitoring and CareLink (OptiLink HF) study is designed to investigate whether OptiVol fluid status monitoring with an automatically generated wireless CareAlert notification via the CareLink Network can reduce all-cause death and cardiovascular hospitalizations in an HF population, compared with standard clinical assessment. Methods Patients with newly implanted or replacement cardioverter-defibrillator devices with or without cardiac resynchronization therapy, who have chronic HF in New York Heart Association class II or III and a left ventricular ejection fraction ≤35% will be eligible to participate. Following device implantation, patients are randomized to either OptiVol fluid status monitoring through CareAlert notification or regular care (OptiLink ‘on' vs. ‘off'). The primary endpoint is a composite of all-cause death or cardiovascular hospitalization. It is estimated that 1000 patients will be required to demonstrate superiority of the intervention group to reduce the primary outcome by 30% with 80% power. Conclusion The OptiLink HF study is designed to investigate whether early detection of congestion reduces mortality and cardiovascular hospitalization in patients with chronic HF. The study is expected to close recruitment in September 2012 and to report first results in May 2014. ClinicalTrials.gov Identifier: NCT00769457 PMID:21555324

  17. The effectiveness of a life style modification and peer support home blood pressure monitoring in control of hypertension: protocol for a cluster randomized controlled trial.

    PubMed

    Su, Tin Tin; Majid, Hazreen Abdul; Nahar, Azmi Mohamed; Azizan, Nurul Ain; Hairi, Farizah Mohd; Thangiah, Nithiah; Dahlui, Maznah; Bulgiba, Awang; Murray, Liam J

    2014-01-01

    Death rates due to hypertension in low and middle income countries are higher compared to high income countries. The present study is designed to combine life style modification and home blood pressure monitoring for control of hypertension in the context of low and middle income countries. The study is a two armed, parallel group, un-blinded, cluster randomized controlled trial undertaken within lower income areas in Kuala Lumpur. Two housing complexes will be assigned to the intervention group and the other two housing complexes will be allocated in the control group. Based on power analysis, 320 participants will be recruited. The participants in the intervention group (n = 160) will undergo three main components in the intervention which are the peer support for home blood pressure monitoring, face to face health coaching on healthy diet and demonstration and training for indoor home based exercise activities while the control group will receive a pamphlet containing information on hypertension. The primary outcomes are systolic and diastolic blood pressure. Secondary outcome measures include practice of self-blood pressure monitoring, dietary intake, level of physical activity and physical fitness. The present study will evaluate the effect of lifestyle modification and peer support home blood pressure monitoring on blood pressure control, during a 6 month intervention period. Moreover, the study aims to assess whether these effects can be sustainable more than six months after the intervention has ended.

  18. The efficacy and stability of an information and communication technology-based centralized monitoring system of adherence to immunosuppressive medication in kidney transplant recipients: study protocol for a randomized controlled trial.

    PubMed

    Jung, Hee-Yeon; Seong, Sook Jin; Choi, Ji-Young; Cho, Jang-Hee; Park, Sun-Hee; Kim, Chan-Duck; Yoon, Young-Ran; Kim, Hyung-Kee; Huh, Seung; Yoon, Se-Hee; Lee, Jong Soo; Kim, Yong-Lim

    2017-10-16

    Immunosuppression non-adherence in kidney transplant recipients (KTRs) not only increases the risk of medical intervention due to acute rejection and graft loss but burdens the socioeconomic system in the form of increased healthcare costs. An aggressive preemptive effort by healthcare professionals, geared to ensure adherence to immunosuppressants in KTRs, is significant and imperative. This study was designed as a prospective, open-label, multicenter, randomized controlled study aimed at evaluating the efficacy and stability of an information and communication technology (ICT)-based centralized monitoring system in boosting medication adherence in KTRs. One hundred fourteen KTRs registered throughout the year 2017 to 2018 are randomized into either the ICT-based centralized home monitoring system or to ambulatory follow-up. The planned follow-up duration is 6 months. The ICT-based centralized home monitoring system described consists of a smart pill box equipped with personal identification system, a home monitoring system, an electronic Case Report Form (eCRF) system, and a comprehensive clinical trial management system (CTMS). It alerts both patients and medical staff with texts and pill box alarms if there is a dosage/dosing time error or a missed dose. Medication adherence and transplant outcomes for the follow-up period are compared between the two groups, while patient satisfaction as well as the stability and cost-effectiveness of the ICT-based monitoring system are to be evaluated. This on-going study is expected to determine if consistent use of the ICT-based centralized monitoring system described could maximize mediation adherence and subsequently enhance transplant outcomes in KTRs. Further, it would lay the foundation for successful implementation of this ICT-based monitoring system for effective management of medication adherence in KTRs. ClinicalTrials.gov, Identifier: NCT03136588 . Registered on 20 April 2017.

  19. Canine Angiostrongylosis in Naturally Infected Dogs: Clinical Approach and Monitoring of Infection after Treatment

    PubMed Central

    Capogna, Antonio; Lia, Riccardo Paolo; Sasanelli, Mariateresa

    2013-01-01

    Canine angiostrongylosis is an increasingly reported disease in Europe which can be fatal if left untreated. The wide range of clinical presentation along with the absence of pathognomonic alterations can make the diagnosis challenging; thus any additional information that may provide clues to an early diagnosis may be of value, in order to ensure adequate anthelmintic treatment. Aim of the study was to assess a clinicopathological scoring system associated with natural Angiostrongylus vasorum infection diagnosed in canine patients during clinical practice, to clinically and paraclinically monitor infected dogs after treatment, and to monitor the presence of L1 larvae in faecal samples by Baermann's test. Of the total 210 enrolled animals A. vasorum infection was diagnosed in 7 dogs. These dogs were clinically and paraclinically investigated and monitored after specific treatment. Further 3 symptomatic dogs were retrospectively included in the monitoring. Results suggest that the computed scoring system can help to increase the clinical suspicion of infection particularly in asymptomatic dogs before the onset of potentially lethal lesions. Data of faecal monitoring suggested that treatment may control parasite burden but be unable to eradicate infection. Thus, a continued faecal monitoring after treatment is advisable for identification of still infected or reinfected dogs. PMID:24459443

  20. Suggested Best Practice for seismic monitoring and characterization of non-conventional reservoirs

    NASA Astrophysics Data System (ADS)

    Malin, P. E.; Bohnhoff, M.; terHeege, J. H.; Deflandre, J. P.; Sicking, C.

    2017-12-01

    High rates of induced seismicity and gas leakage in non-conventional production have become a growing issue of public concern. It has resulted in calls for independent monitoring before, during and after reservoir production. To date no uniform practice for it exists and few reservoirs are locally monitored at all. Nonetheless, local seismic monitoring is a pre-requisite for detecting small earthquakes, increases of which can foreshadow damaging ones and indicate gas leaks. Appropriately designed networks, including seismic reflection studies, can be used to collect these and Seismic Emission Tomography (SET) data, the latter significantly helping reservoir characterization and exploitation. We suggest a Step-by-Step procedure for implementing such networks. We describe various field kits, installations, and workflows, all aimed at avoiding damaging seismicity, as indicators of well stability, and improving reservoir exploitation. In Step 1, a single downhole seismograph is recommended for establishing baseline seismicity before development. Subsequent Steps are used to decide cost-effective ways of monitoring treatments, production, and abandonment. We include suggestions for monitoring of disposal and underground storage. We also describe how repeated SET observations improve reservoir management as well as regulatory monitoring. Moreover, SET acquisition can be included at incremental cost in active surveys or temporary passive deployments.

  1. Explore the advantage of High-frequency Water Quality Data in Urban Surface Water: A Case Study in Bristol, UK

    NASA Astrophysics Data System (ADS)

    Chen, Y.; Han, D.

    2017-12-01

    Water system is an essential component in a smart city for its sustainability and resilience. The freshness and beauty of the water body would please people as well as benefit the local aquatic ecosystems. Water quality monitoring approach has evolved from the manual lab-based monitoring approach to the manual in-situ monitoring approach, and finally to the latest wireless-sensor-network (WSN) based solutions in recent decades. The development of the in-situ water quality sensors enable humans to collect high-frequency and real-time water quality data. This poster aims to explore the advantages of the high-frequency water quality data over the low-frequency data collected manually. The data is collected by a remote real-time high-frequency water quality monitor system based on the cutting edge smart city infrastructure in Bristol - `Bristol Is Open'. The water quality of Bristol Floating Harbour is monitored which is the focal area of Bristol with new buildings and features redeveloped in the past decades. This poster will first briefly introduce the water quality monitoring system, followed by the analysis of the advantages of the sub-hourly water quality data. Thus, the suggestion on the monitoring frequency will be given.

  2. Crack classification in concrete beams using AE parameters

    NASA Astrophysics Data System (ADS)

    Bahari, N. A. A. S.; Shahidan, S.; Abdullah, S. R.; Ali, N.; Zuki, S. S. Mohd; Ibrahim, M. H. W.; Rahim, M. A.

    2017-11-01

    The acoustic emission (AE) technique is an effective tool for the evaluation of crack growth. The aim of this study is to evaluate crack classification in reinforced concrete beams using statistical analysis. AE has been applied for the early monitoring of reinforced concrete structures using AE parameters such as average frequency, rise time, amplitude counts and duration. This experimental study focuses on the utilisation of this method in evaluating reinforced concrete beams. Beam specimens measuring 150 mm × 250 mm × 1200 mm were tested using a three-point load flexural test using Universal Testing Machines (UTM) together with an AE monitoring system. The results indicated that RA value can be used to determine the relationship between tensile crack and shear movement in reinforced concrete beams.

  3. Ethical issues in using Twitter for population-level depression monitoring: a qualitative study.

    PubMed

    Mikal, Jude; Hurst, Samantha; Conway, Mike

    2016-04-14

    Recently, significant research effort has focused on using Twitter (and other social media) to investigate mental health at the population-level. While there has been influential work in developing ethical guidelines for Internet discussion forum-based research in public health, there is currently limited work focused on addressing ethical problems in Twitter-based public health research, and less still that considers these issues from users' own perspectives. In this work, we aim to investigate public attitudes towards utilizing public domain Twitter data for population-level mental health monitoring using a qualitative methodology. The study explores user perspectives in a series of five, 2-h focus group interviews. Following a semi-structured protocol, 26 Twitter users with and without a diagnosed history of depression discussed general Twitter use, along with privacy expectations, and ethical issues in using social media for health monitoring, with a particular focus on mental health monitoring. Transcripts were then transcribed, redacted, and coded using a constant comparative approach. While participants expressed a wide range of opinions, there was an overall trend towards a relatively positive view of using public domain Twitter data as a resource for population level mental health monitoring, provided that results are appropriately aggregated. Results are divided into five sections: (1) a profile of respondents' Twitter use patterns and use variability; (2) users' privacy expectations, including expectations regarding data reach and permanence; (3) attitudes towards social media based population-level health monitoring in general, and attitudes towards mental health monitoring in particular; (4) attitudes towards individual versus population-level health monitoring; and (5) users' own recommendations for the appropriate regulation of population-level mental health monitoring. Focus group data reveal a wide range of attitudes towards the use of public-domain social media "big data" in population health research, from enthusiasm, through acceptance, to opposition. Study results highlight new perspectives in the discussion of ethical use of public data, particularly with respect to consent, privacy, and oversight.

  4. LANDMON a new integrated system for the management of landslide monitoring networks

    NASA Astrophysics Data System (ADS)

    Wrzesniak, Aleksandra; Giordan, Daniele; Allasia, Paolo

    2017-04-01

    Over the last decades, technological development has strongly increased the number of instruments that can be used to monitor landslide phenomena. Robotized Total Stations, GB-InSAR and GPS are only few examples of the devices that can be adapted to monitor the topographic changes due to mass movements. They are often organized in a complex network, aimed at controlling physical parameters related to the evolution of landslide activity. The level of complexity of these monitoring networks increases with the number of new available monitoring devices and this could generate a paradox: the source of data is so numerous and difficult to interpret that a full understanding of the phenomenon could be hampered. The Geohazard Monitoring Group (GMG) of Italian National Research Council (CNR) has a long experience in landslide monitoring. Over the years, GMG has developed a multidisciplinary approach for landslide management strategy called LANDMON (LANDslide MOnitoring Network). It is an automatic hybrid system focused not only on capturing and elaborating data from monitored site but also on web applications and on publishing bulletins aimed to disseminate monitoring results and to support decision makers. LANDMON is currently active in many landslide sites distributed in several areas in Italy and in Europe. LANDMON is derived from the previously developed systems like ADVICE (ADVanced dIsplaCement monitoring system for Early warning) and 3DA (three-dimensional Displacement Analysis). These systems are aimed to collect and to process monitoring dataset, to manage early warning application based on pre-defined thresholds, and to publish three-dimensional displacement maps in near real time. In addition, LANDMON integrates several new features, such as WebGIS application, modelling using inverse velocity method, and management of webcam monitoring system, meteorological parameters and borehole inclinometric data. Moreover, LANDMON is a communication strategy that focuses on dissemination of the landslide monitoring results in order to obtain a user-friendly system. In fact, this kind of results are usually very complex and they are dedicated exclusively to professionals with a proper background. This approach may be inefficient during the management of emergencies, especially when groups of non-expert people (decision and policy makers, population) are involved. For this purpose, an automatic procedure to produce a single page bulletin has been developed. The algorithm performs the analysis of complex data regarding the activity of the monitored landslide, but the results shared with end-users of LANDMON are summarized in a clear, illustrative and quickly interpretable manner. Therefore, LANDMON is a complex, complete and self-contained system, designed for efficient acquisition, analysis, representation and appropriate dissemination of the monitoring data.

  5. Understanding Monitoring Technologies for Adults With Pain: Systematic Literature Review.

    PubMed

    Rodríguez, Iyubanit; Herskovic, Valeria; Gerea, Carmen; Fuentes, Carolina; Rossel, Pedro O; Marques, Maíra; Campos, Mauricio

    2017-10-27

    Monitoring of patients may decrease treatment costs and improve quality of care. Pain is the most common health problem that people seek help for in hospitals. Therefore, monitoring patients with pain may have significant impact in improving treatment. Several studies have studied factors affecting pain; however, no previous study has reviewed the contextual information that a monitoring system may capture to characterize a patient's situation. The objective of this study was to conduct a systematic review to (1) determine what types of technologies have been used to monitor adults with pain, and (2) construct a model of the context information that may be used to implement apps and devices aimed at monitoring adults with pain. A literature search (2005-2015) was conducted in electronic databases pertaining to medical and computer science literature (PubMed, Science Direct, ACM Digital Library, and IEEE Xplore) using a defined search string. Article selection was done through a process of removing duplicates, analyzing title and abstract, and then reviewing the full text of the article. In the final analysis, 87 articles were included and 53 of them (61%) used technologies to collect contextual information. A total of 49 types of context information were found and a five-dimension (activity, identity, wellness, environment, physiological) model of context information to monitor adults with pain was proposed, expanding on a previous model. Most technological interfaces for pain monitoring were wearable, possibly because they can be used in more realistic contexts. Few studies focused on older adults, creating a relevant avenue of research on how to create devices for users that may have impaired cognitive skills or low digital literacy. The design of monitoring devices and interfaces for adults with pain must deal with the challenge of selecting relevant contextual information to understand the user's situation, and not overburdening or inconveniencing users with information requests. A model of contextual information may be used by researchers to choose possible contextual information that may be monitored during studies on adults with pain. ©Iyubanit Rodríguez, Valeria Herskovic, Carmen Gerea, Carolina Fuentes, Pedro O Rossel, Maíra Marques, Mauricio Campos. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 27.10.2017.

  6. Facilitators and barriers for the adoption, implementation and monitoring of child safety interventions: a multinational qualitative analysis.

    PubMed

    Scholtes, Beatrice; Schröder-Bäck, Peter; MacKay, J Morag; Vincenten, Joanne; Förster, Katharina; Brand, Helmut

    2017-06-01

    The efficiency and effectiveness of child safety interventions are determined by the quality of the implementation process. This multinational European study aimed to identify facilitators and barriers for the three phases of implementation: adoption, implementation and monitoring (AIM process). Twenty-seven participants from across the WHO European Region were invited to provide case studies of child safety interventions from their country. Cases were selected by the authors to ensure broad coverage of injury issues, age groups and governance level of implementation (eg, national, regional or local). Each participant presented their case and provided a written account according to a standardised template. Presentations and question and answer sessions were recorded. The presentation slides, written accounts and the notes taken during the workshops were analysed using thematic content analysis to elicit facilitators and barriers. Twenty-six cases (from 26 different countries) were presented and analysed. Facilitators and barriers were identified within eight general themes, applicable across the AIM process: management and collaboration; resources; leadership; nature of the intervention; political, social and cultural environment; visibility; nature of the injury problem and analysis and interpretation. The importance of the quality of the implementation process for intervention effectiveness, coupled with limited resources for child safety makes it more difficult to achieve successful actions. The findings of this study, divided by phase of the AIM process, provide practitioners with practical suggestions, where proactive planning might help increase the likelihood of effective implementation. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  7. Three-month validation of a turbuhaler electronic monitoring device: implications for asthma clinical trial use

    PubMed Central

    Pilcher, Janine; Shirtcliffe, Philippa; Patel, Mitesh; McKinstry, Steve; Cripps, Terrianne; Weatherall, Mark; Beasley, Richard

    2015-01-01

    Background Electronic monitoring of inhaled asthma therapy is suggested as the ‘gold standard’ for measuring patterns of medication use in clinical trials. The SmartTurbo (Adherium (NZ) Ltd, Auckland, New Zealand) is an electronic monitor for use with a turbuhaler device (AstraZeneca, UK). The aim of this study was to determine the accuracy of the SmartTurbo in recording Symbicort actuations over a 12-week period of use. Methods Twenty SmartTurbo monitors were attached to the base of 20 Symbicort turbuhalers. Bench testing in a research facility was undertaken on days 0, 5, 6, 7, 8, 9, 14, 21, 28, 56 and 84. Patterns of ‘low-use’ (2 sets of 2 actuations on the same day) and ‘high-use’ (2 sets of 8 actuations on the same day) were performed. The date and time of actuations were recorded in a paper diary and compared with data uploaded from the SmartTurbo monitors. Results 2800 actuations were performed. Monitor sensitivity was 99.9% with a lower 97.5% confidence bound of 99.6%. The positive predictive value was 99.9% with a 97.5% lower confidence bound of 99.7%. Accuracy was not affected by whether the pattern of inhaler use was low or high, or whether there was a delay in uploading the actuation data. Conclusions The SmartTurbo monitor is highly accurate in recording and retaining electronic data in this 12-week bench study. It can be recommended for use in clinical trial settings, in which quality control systems are incorporated into study protocols to ensure accurate data acquisition. PMID:26629345

  8. Remote sensing of Northern mines: supporting operation and environmental monitoring in cold conditions

    NASA Astrophysics Data System (ADS)

    Tuomela, Anne; Davids, Corine; Knutsson, Sven; Knutsson, Roger; Rauhala, Anssi; Rossi, Pekka M.; Rouyet, Line

    2017-04-01

    Northern areas of Finland, Sweden and Norway have mineral-rich deposits. There are several active mines in the area but also closed ones and deposits with plans for future mining. With increasing demand for environmental protection in the sensitive Northern conditions, there is a need for more comprehensive monitoring of the mining environment. In our study, we aim to develop new opportunities to use remote sensing data from satellites and unmanned aerial vehicles (UAVs) in improving mining safety and monitoring, for example in the case of mine waste storage facilities. Remote sensing methods have evolved fast, and could in many cases enable precise, reliable, and cost-efficient data collection over large areas. The study has focused on four mining areas in Northern Fennoscandia. Freely available medium-resolution (e.g. Sentinel-1), commercial high-resolution (e.g. TerraSAR-X) and Synthetic Aperture Radar (SAR) data has been collected during 2015-2016 to study how satellite remote sensing could be used e.g. for displacement monitoring using SAR Interferometry (InSAR). Furthermore, UAVs have been utilized in similar data collection in a local scale, and also in collection of thermal infrared data for hydrological monitoring of the areas. The development and efficient use of the methods in mining areas requires experts from several fields. In addition, the Northern conditions with four distinct seasons bring their own challenges for the efficient use of remote sensing, and further complicate their integration as standardised monitoring methods for mine environments. Based on the initial results, remote sensing could especially enhance the monitoring of large-scale structures in mine areas such as tailings impoundments.

  9. Impact of feedback on physical activity levels of individuals with chronic obstructive pulmonary disease during pulmonary rehabilitation: A feasibility study.

    PubMed

    Cruz, Joana; Brooks, Dina; Marques, Alda

    2014-11-01

    This study aimed at investigating whether providing feedback on physical activity (PA) levels to patients with chronic obstructive pulmonary disease (COPD) is feasible and enhances daily PA during pulmonary rehabilitation (PR). Patients with COPD participated in a 12-week PR program. Daily PA was measured using activity monitors on weeks 1, 7, and 12, and feedback was given in the following weeks on the number of steps, time spent in sedentary, light, and moderate-to-vigorous intensity activities, and time spent standing, sitting, and lying. Compliance with PA monitoring was collected. Two focus groups were conducted to obtain patients' perspectives on the use of activity monitors and on the feedback given. Differences in PA data were also assessed. Sixteen patients (65.63 ± 10.57 years; forced expiratory volume in one second (FEV1) 70.31 ± 22.74% predicted) completed the study. From those, only eleven participants used the activity monitors during all monitoring days. Participants identified several problems regarding the use of activity monitors and monitoring duration. Daily steps (p = 0.026) and standing time (p = 0.030) were improved from week 1 to week 7; however, the former declined from week 7 to week 12. Findings suggest that using feedback to improve PA during PR is feasible and results in improved daily steps and standing time on week 7. The subsequent decline suggests that additional strategies may be needed to stimulate/maintain PA improvements. Further research with more robust designs is needed to investigate the impact of feedback on patients' daily PA. © The Author(s) 2014.

  10. Amalgamation of management information system into anaesthesiology practice: A boon for the modern anaesthesiologists

    PubMed Central

    Bajwa, Sukhminder Jit Singh

    2014-01-01

    Over the years, traditional anaesthesia record keeping system has been the backbone of anaesthesiology ever since its introduction in the 1890s by Dr. Harvey Cushing and Dr. Ernest A. Codman. Besides providing the important information regarding patients’ vital physiologic parameters, paper records had been a reliable source for various clinical research activities. The introduction of electronic monitoring gadgets and electronic record keeping systems has revolutionised the anaesthesiology practice to a large extent. Recently, the introduction of anaesthesia information management system (AIMS), which incorporates all the features of monitoring gadgets, such as electronic storage of large accurate data, quality assurance in anaesthesia, enhancing patient safety, ensuring legal protection, improved billing services and effecting an organisational change, is almost a revolution in modern-day anaesthesiology practice. The clinical research activities that are responsible for taking anaesthesiology discipline to higher peaks have also been boosted by the amalgamation of AIMS, enabling multicenter studies and sharing of clinical data. Barring few concerns in its installation, cost factors and functional aspects, the future of AIMS seems to be bright and will definitely prove to be a boon for modern-day anaesthesiology practice. PMID:24963173

  11. Refinery evaluation of optical imaging to locate fugitive emissions.

    PubMed

    Robinson, Donald R; Luke-Boone, Ronke; Aggarwal, Vineet; Harris, Buzz; Anderson, Eric; Ranum, David; Kulp, Thomas J; Armstrong, Karla; Sommers, Ricky; McRae, Thomas G; Ritter, Karin; Siegell, Jeffrey H; Van Pelt, Doug; Smylie, Mike

    2007-07-01

    Fugitive emissions account for approximately 50% of total hydrocarbon emissions from process plants. Federal and state regulations aiming at controlling these emissions require refineries and petrochemical plants in the United States to implement a Leak Detection and Repair Program (LDAR). The current regulatory work practice, U.S. Environment Protection Agency Method 21, requires designated components to be monitored individually at regular intervals. The annual costs of these LDAR programs in a typical refinery can exceed US$1,000,000. Previous studies have shown that a majority of controllable fugitive emissions come from a very small fraction of components. The Smart LDAR program aims to find cost-effective methods to monitor and reduce emissions from these large leakers. Optical gas imaging has been identified as one such technology that can help achieve this objective. This paper discusses a refinery evaluation of an instrument based on backscatter absorption gas imaging technology. This portable camera allows an operator to scan components more quickly and image gas leaks in real time. During the evaluation, the instrument was able to identify leaking components that were the source of 97% of the total mass emissions from leaks detected. More than 27,000 components were monitored. This was achieved in far less time than it would have taken using Method 21. In addition, the instrument was able to find leaks from components that are not required to be monitored by the current LDAR regulations. The technology principles and the parameters that affect instrument performance are also discussed in the paper.

  12. Quality aspects of digital radiography in general dental practice.

    PubMed

    Hellén-Halme, Kristina

    2007-01-01

    The number of dentists who have converted from conventional film radiography to digital radiography continues to grow. A digital system has numerous advantages, but there are also many new aspects to consider. The overall aim of this thesis was to study how digital radiography was used in general dental practices. The specific aims were to study how different factors affected image quality. To determine whether there were any differences in image quality between conventional film radiographs and digital radiographs, 4863 images (540 cases) were evaluated. The cases had been sent to the Swedish Dental Insurance Office for prior treatment approval. The image quality of digital radiographs was found to be significantly lower than that of film radiographs. This result led to a questionnaire study of dentists experienced in digital radiography. In 2003, a questionnaire was sent to the 139 general practice dentists who worked with digital radiography in Skine, Sweden; the response rate was 94%. Many general practice dentists had experienced several problems (65%), and less than half of the digital systems (40%) underwent some kind of quality control. One of the weaker links in the technical chain of digital radiography appeared to be the monitor. A field study to 19 dentists at their clinics found that the brightness and contrast settings of the monitors had to be adjusted to obtain the subjectively best image quality. The ambient light in the evaluation room was also found to affect the diagnostic outcome of low-contrast patterns in radiographs. To evaluate the effects of ambient light and technical adjustments of the monitor, a study using standardised set-ups was designed. Seven observers evaluated radiographs of 100 extracted human teeth for approximal caries under five different combinations of brightness and contrast settings on two different occasions with high and low ambient light levels in the evaluation room. The ability to diagnose carious lesions was found to be significantly better in a room with lower ambient light and on a monitor with well-adjusted brightness and contrast values than in a room with bright light and on an unadjusted monitor. In conclusion, many problems with dental digital radiography were identified. Knowledge of digital techniques and how to optimise each link in the system to maintain high radiographic quality at all times must be improved.

  13. Determination of uncertainties associated to the in vivo measurement of iodine-131 in the thyroid.

    PubMed

    Dantas, B M; Lima, F F; Dantas, A L; Lucena, E A; Gontijo, R M G; Carvalho, C B; Hazin, C

    2016-07-01

    Intakes of radionuclides can be estimated through in vivo measurements, and the uncertainties associated to the measured activities should be clearly stated in monitoring program reports. This study aims to evaluate the uncertainties of in vivo monitoring of iodine 131 in the thyroid. The reference values for high-energy photons are based on the IDEAS Guide. Measurements were performed at the In Vivo Monitoring Laboratory of the Institute of Radiation Protection and Dosimetry (IRD) and at the Internal Dosimetry Laboratory of the Regional Center of Nuclear Sciences (CRCN-NE). In both institutions, the experiment was performed using a NaI(Tl) 3''3″ scintillation detector and a neck-thyroid phantom. Scattering factors were calculated and compared in different counting geometries. The results show that the technique produces reproducibility equivalent to the values suggested in the IDEAS Guide and measurement uncertainties is comparable to international quality standards for this type of in vivo monitoring. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Small-scale loess landslide monitoring with small baseline subsets interferometric synthetic aperture radar technique-case study of Xingyuan landslide, Shaanxi, China

    NASA Astrophysics Data System (ADS)

    Zhao, Chaoying; Zhang, Qin; He, Yang; Peng, Jianbing; Yang, Chengsheng; Kang, Ya

    2016-04-01

    Small baseline subsets interferometric synthetic aperture radar technique is analyzed to detect and monitor the loess landslide in the southern bank of the Jinghe River, Shaanxi province, China. Aiming to achieve the accurate preslide time-series deformation results over small spatial scale and abrupt temporal deformation loess landslide, digital elevation model error, coherence threshold for phase unwrapping, and quality of unwrapping interferograms must be carefully checked in advance. In this experience, land subsidence accompanying a landslide with the distance <1 km is obtained, which gives a sound precursor for small-scale loess landslide detection. Moreover, the longer and continuous land subsidence has been monitored while deformation starting point for the landslide is successfully inverted, which is key to monitoring the similar loess landslide. In addition, the accelerated landslide deformation from one to two months before the landslide can provide a critical clue to early warning of this kind of landslide.

  15. BreathSens: A Continuous On-Bed Respiratory Monitoring System With Torso Localization Using an Unobtrusive Pressure Sensing Array.

    PubMed

    Liu, Jason J; Huang, Ming-Chun; Xu, Wenyao; Zhang, Xiaoyi; Stevens, Luke; Alshurafa, Nabil; Sarrafzadeh, Majid

    2015-09-01

    The ability to continuously monitor respiration rates of patients in homecare or in clinics is an important goal. Past research showed that monitoring patient breathing can lower the associated mortality rates for long-term bedridden patients. Nowadays, in-bed sensors consisting of pressure sensitive arrays are unobtrusive and are suitable for deployment in a wide range of settings. Such systems aim to extract respiratory signals from time-series pressure sequences. However, variance of movements, such as unpredictable extremities activities, affect the quality of the extracted respiratory signals. BreathSens, a high-density pressure sensing system made of e-Textile, profiles the underbody pressure distribution and localizes torso area based on the high-resolution pressure images. With a robust bodyparts localization algorithm, respiratory signals extracted from the localized torso area are insensitive to arbitrary extremities movements. In a study of 12 subjects, BreathSens demonstrated its respiratory monitoring capability with variations of sleep postures, locations, and commonly tilted clinical bed conditions.

  16. A network of autonomous surface ozone monitors in Antarctica: technical description and first results

    NASA Astrophysics Data System (ADS)

    Bauguitte, S. J.; Brough, N.; Frey, M. M.; Jones, A. E.; Roscoe, H. K.; Wolff, E. W.

    2009-12-01

    Concentrations of surface ozone over polar regions cannot be derived from satellite data so can only be studied from ground-based platforms. To understand the regional picture a carefully-designed network of ground-based monitors is required. Here we report on a network of 10 autonomous ozone monitors that was established around the Weddell Sea sector of coastal Antarctica with a transect up onto the Antarctic Plateau during the International Polar Year. The aim was to measure for a full year, thus gaining a much-improved broader view of boundary layer ozone seasonality at different locations as well as on factors affecting the budget of surface ozone in Antarctica. Of specific interest were the balance between halogen-driven destruction and photochemical production from snow-emitted precursors, as well as the spatial extent of ozone depletion events. Each ozone monitor measured successfully within its predefined duty cycle throughout the year, with some differences in performance dependent on power availability. Here we present technical information and first results from the network.

  17. Amphibian and reptile road-kills on tertiary roads in relation to landscape structure: using a citizen science approach with open-access land cover data.

    PubMed

    Heigl, Florian; Horvath, Kathrin; Laaha, Gregor; Zaller, Johann G

    2017-06-26

    Amphibians and reptiles are among the most endangered vertebrate species worldwide. However, little is known how they are affected by road-kills on tertiary roads and whether the surrounding landscape structure can explain road-kill patterns. The aim of our study was to examine the applicability of open-access remote sensing data for a large-scale citizen science approach to describe spatial patterns of road-killed amphibians and reptiles on tertiary roads. Using a citizen science app we monitored road-kills of amphibians and reptiles along 97.5 km of tertiary roads covering agricultural, municipal and interurban roads as well as cycling paths in eastern Austria over two seasons. Surrounding landscape was assessed using open access land cover classes for the region (Coordination of Information on the Environment, CORINE). Hotspot analysis was performed using kernel density estimation (KDE+). Relations between land cover classes and amphibian and reptile road-kills were analysed with conditional probabilities and general linear models (GLM). We also estimated the potential cost-efficiency of a large scale citizen science monitoring project. We recorded 180 amphibian and 72 reptile road-kills comprising eight species mainly occurring on agricultural roads. KDE+ analyses revealed a significant clustering of road-killed amphibians and reptiles, which is an important information for authorities aiming to mitigate road-kills. Overall, hotspots of amphibian and reptile road-kills were next to the land cover classes arable land, suburban areas and vineyards. Conditional probabilities and GLMs identified road-kills especially next to preferred habitats of green toad, common toad and grass snake, the most often found road-killed species. A citizen science approach appeared to be more cost-efficient than monitoring by professional researchers only when more than 400 km of road are monitored. Our findings showed that freely available remote sensing data in combination with a citizen science approach would be a cost-efficient method aiming to identify and monitor road-kill hotspots of amphibians and reptiles on a larger scale.

  18. Accelerated Aging Experiments for Capacitor Health Monitoring and Prognostics

    NASA Technical Reports Server (NTRS)

    Kulkarni, Chetan S.; Celaya, Jose Ramon; Biswas, Gautam; Goebel, Kai

    2012-01-01

    This paper discusses experimental setups for health monitoring and prognostics of electrolytic capacitors under nominal operation and accelerated aging conditions. Electrolytic capacitors have higher failure rates than other components in electronic systems like power drives, power converters etc. Our current work focuses on developing first-principles-based degradation models for electrolytic capacitors under varying electrical and thermal stress conditions. Prognostics and health management for electronic systems aims to predict the onset of faults, study causes for system degradation, and accurately compute remaining useful life. Accelerated life test methods are often used in prognostics research as a way to model multiple causes and assess the effects of the degradation process through time. It also allows for the identification and study of different failure mechanisms and their relationships under different operating conditions. Experiments are designed for aging of the capacitors such that the degradation pattern induced by the aging can be monitored and analyzed. Experimental setups and data collection methods are presented to demonstrate this approach.

  19. Aerophagia: excessive air swallowing demonstrated by esophageal impedance monitoring.

    PubMed

    Hemmink, Gerrit J M; Weusten, Bas L A M; Bredenoord, Albert J; Timmer, Robin; Smout, André J P M

    2009-10-01

    Patients with aerophagia suffer from the presence of an excessive volume of intestinal gas, which is thought to result from excessive air ingestion. However, this has not been shown thus far. The aim of this study was therefore to assess swallowing and air swallowing frequencies in patients with suspected aerophagia. Ambulatory 24-hour pH-impedance monitoring was performed in patients in whom excessive amounts of intestinal gas were visualized on plain abdominal radiograms. All patients had symptoms of bloating, abdominal distention, flatulence, or excessive belching. Reflux parameters and the number of swallows and air swallows were assessed. The most common symptoms were bloating, abdominal distention, and constipation. Only 3 patients reported excessive belching and 1 patient reported flatulence as their predominant symptom. During the 24-hour measurement, patients showed high incidences of air swallows (521 +/- 63) and gastric belches (126 +/- 37). Patients had normal swallowing frequency (741 +/- 71). This study presents objective parameters that confirm the existence of excessive air swallowing or aerophagia using esophageal impedance monitoring.

  20. Environmental exposure to arsenic and chromium in an industrial area.

    PubMed

    Vimercati, Luigi; Gatti, Maria F; Gagliardi, Tommaso; Cuccaro, Francesco; De Maria, Luigi; Caputi, Antonio; Quarato, Marco; Baldassarre, Antonio

    2017-04-01

    Arsenic and chromium are widespread environmental contaminants that affect global health due to their toxicity and carcinogenicity. To date, few studies have investigated exposure to arsenic and chromium in a population residing in a high-risk environmental area. The aim of this study is to evaluate the exposure to arsenic and chromium in the general population with no occupational exposure to these metals, resident in the industrial area of Taranto, Southern Italy, through biological monitoring techniques. We measured the levels of chromium, inorganic arsenic, and methylated metabolites, in the urine samples of 279 subjects residing in Taranto and neighboring areas. Qualified health staff administered a standardized structured questionnaire investigating lifestyle habits and controlling for confounding factors. The biological monitoring data showed high urinary concentrations of both the heavy metals investigated, particularly Cr. On this basis, it will be necessary to carry out an organized environmental monitoring program, taking into consideration all exposure routes so as to correlate the environmental concentrations of these metals with the biomonitoring results.

  1. Advances in Scientific Possibilities Offered by Real-Time Monitoring Technology.

    PubMed

    Kleiman, Evan M; Nock, Matthew K

    2017-01-01

    There has been a marked increase in research aimed at studying dynamic (e.g., day-to-day, moment-to-moment) changes in mental disorders and related behavior problems. Indeed, the number of scientific papers published that focus on real-time monitoring has been nearly doubling every five years for the past several decades. These methods allow for a more fine-grained description of phenomena of interest as well as for real-world tests of theoretical models of human behavior. Here we comment on the recent study by van Winkel and colleagues (this issue)as an excellent example of the use of real-time monitoring methods to better understand mental disorders. We also discuss the expanding universe of new technologies (e.g., smartphones, wearable biosensors) that can be used to make discoveries about psychopathology and related constructs and describe what we perceive to be some of the most exciting scientific possibilities that can be achieved in the near term by taking advantage of these new and rapidly developing tools.

  2. The effect of health payment reforms on cost containment in Taiwan hospitals: the agency theory perspective.

    PubMed

    Chang, Li

    2011-01-01

    This study aims to determine whether the Taiwanese government's implementation of new health care payment reforms (the National Health Insurance with fee-for-service (NHI-FFS) and global budget (NHI-GB)) has resulted in better cost containment. Also, the question arises under the agency theory whether the monitoring system is effective in reducing the risk of information asymmetry. This study uses panel data analysis with fixed effects model to investigate changes in cost containment at Taipei municipal hospitals before and after adopting reforms from 1989 to 2004. The results show that the monitoring system does not reduce information asymmetry to improve cost containment under the NHI-FFS. In addition, after adopting the NHI-GB system, health care costs are controlled based on an improved monitoring system in the policymaker's point of view. This may suggest that the NHI's fee-for-services system actually causes health care resource waste. The GB may solve the problems of controlling health care costs only on the macro side.

  3. Engagement Strategies for Self-Monitoring Symptoms of Bipolar Disorder With Mobile and Wearable Technology: Protocol for a Randomized Controlled Trial.

    PubMed

    Cochran, Amy; Belman-Wells, Livia; McInnis, Melvin

    2018-05-10

    Monitoring signs and symptoms in bipolar disorder (BP) is typically based on regular assessments from patient-clinician interactions. Mobile and wearable technology promises to make monitoring symptoms in BP easier, but little is known about how best to engage individuals with BP in monitoring symptoms. The objective of this study was to provide the rationale and protocol for a randomized controlled trial that investigates engagement strategies for monitoring symptoms of BP, including the strategies of using activity trackers compared with self-reports and reviewing recorded symptoms weekly with an interviewer. A total of 50 individuals with BP will be recruited from the Prechter Longitudinal Study of Bipolar Disorder at the University of Michigan to participate in a 6-week study. Participants will monitor their symptoms through an activity tracker (Fitbit Alta HR) and a mobile phone app designed for this study. In addition to monitoring symptoms, participants have a 50-50 chance of being assigned to an arm that reviews self-reports and activity information weekly. Statistical tests will be performed to test hypotheses that participants adhere to activity tracking significantly more than self-reporting, prefer activity tracking significantly more than self-reporting, and better adhere to both activity tracking and self-reporting when reviewing collected information weekly. Recruitment commenced in November 2017. The first group of participants began the study in January 2018. This study aims to establish strategies to engage individuals with BP in monitoring their symptoms with mobile and wearable technology. Better engagement strategies are expected to aid current efforts in bipolar research and clinical care, from the development of new mobile phone apps to providing the right intervention to the right individual at the right moment. ClinicalTrials.gov NCT03358238; https://clinicaltrials.gov/ct2/show/NCT03358238 (Archived by WebCite at http://www.webcitation.org/6yebuNfz5). RR1-10.2196/9899. ©Amy Cochran, Livia Belman-Wells, Melvin McInnis. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 10.05.2018.

  4. Deciphering the Sensitivity and Specificity of the Implantable Doppler Probe in Free Flap Monitoring.

    PubMed

    Chang, Edward I; Ibrahim, Amir; Zhang, Hong; Liu, Jun; Nguyen, Alexander T; Reece, Gregory P; Yu, Peirong

    2016-03-01

    The efficacy of implantable Doppler probes remains an area of considerable debate. This study aims to decipher its sensitivity and specificity for free flap monitoring. A retrospective review of all free flaps with an implantable Doppler probe was performed between 2000 and 2012. A Cook-Swartz implantable Doppler probe was used in 439 patients (head and neck, n = 364; breast, n = 53; extremity, n = 22), and demonstrated equivalent sensitivity and specificity between flap types. The overall sensitivity and specificity were 77.8 percent and 88.4 percent, respectively. The artery was monitored in 267 patients, compared to venous monitoring in 101 patients, and in 71 patients both the artery and vein were monitored. Arterial monitoring had significantly greater specificity than venous monitoring, (94.2 percent versus 74.0 percent; p < 0.001), but no benefit was found in monitoring both the artery and the vein. Venous monitoring was significantly associated with reoperation (OR, 3.17; 95 percent CI, 1.70 to 5.91; p = 0.0003). There were 284 flaps that had a monitoring segment in addition to the implantable Doppler probe that significantly increased overall specificity for microvascular complications (OR, 17.71; 95 percent CI, 3.39 to 92.23; p = 0.0006). The specificity (90.5 percent versus 84.8 percent) and sensitivity (80.0 percent versus 66.7 percent) were significantly higher for clinically monitored flaps. The take-back rate was 13.0 percent, with positive findings in 59.6 percent, and 5.2 percent total flap loss. The use of implantable Doppler probes has high sensitivity and specificity for buried free flaps despite positive findings in less than 60 percent of take-backs. Monitoring the artery is recommended, but clinical examination remains the gold standard for flap monitoring. Diagnostic, IV.

  5. Food Fortification Stability Study

    NASA Technical Reports Server (NTRS)

    Sirmons, T. A.; Cooper, M. R.; Douglas, G. L.

    2016-01-01

    This study aims to assess the stability of vitamin content, sensory acceptability and color variation in fortified spaceflight foods over a period of 2 years. Findings will identify optimal formulation, processing, and storage conditions to maintain stability and acceptability of commercially available fortification nutrients. Changes in food quality are being monitored to indicate whether fortification affects quality over time (compared to the unfortified control), thus indicating their potential for use on long-duration missions.

  6. Walk Test Used to Monitor the Performance in the Health-Directed Nordic Walking

    ERIC Educational Resources Information Center

    Kamien, Dorota

    2008-01-01

    Study aim: To assess the performance of subjects engaged in health-directed Nordic Walking training (with poles) and subjected to 2-km walk test (no poles). Material and methods: A total of 72 subjects, including 8 men and 32 women aged 23-73 years and 32 female students aged 19-25 years participated in the study. They were subjected twice to 2-km…

  7. Food Fortification Stability Study

    NASA Technical Reports Server (NTRS)

    Sirmons, T. A.; Cooper, M. R.; Douglas, G. L.

    2017-01-01

    This study aimed to assess the stability of vitamin content, sensory acceptability and color variation in fortified spaceflight foods over a period of two years. Findings will help to identify optimal formulation, processing, and storage conditions to maintain stability and acceptability of commercially available fortification nutrients. Changes in food quality were monitored to indicate whether fortification affects quality over time (compared to the unfortified control), thus indicating their potential for use on long-duration missions.

  8. [Effect of short term graded physical exercise on the level of glycemia in children and adolescents with type 1 diabetes mellitus: data of long term ECG monitoring and registration of motor activity].

    PubMed

    Laptev, D N; Kruzhkova, M N; Riabykina, G V; Poliakov, S D; Korneeva, I T

    2012-01-01

    Study aim was to elucidate effect of graded physical exercise on glycemia level and interval QT duration in children and adolescents with type 1 diabetes mellitus. We carried out 25-hours parallel monitoring of glycemia, ECG and physical activity in 15 children and adolescents aged 9-17 years. During monitoring these patients performed an exercise test (PWC170). We found that there were two periods of significant and prolonged lowering of glycemia: in 120-420 min and 19-21 hours after exercise. Lowering of glycemia after physical exercise was associated with prolongation of QT interval. Registration of motor activity allowed to exclude changes of glycemia due to physical activity unrelated to graded exercise.

  9. Wireless body sensor networks for health-monitoring applications.

    PubMed

    Hao, Yang; Foster, Robert

    2008-11-01

    Current wireless technologies, such as wireless body area networks and wireless personal area networks, provide promising applications in medical monitoring systems to measure specified physiological data and also provide location-based information, if required. With the increasing sophistication of wearable and implantable medical devices and their integration with wireless sensors, an ever-expanding range of therapeutic and diagnostic applications is being pursued by research and commercial organizations. This paper aims to provide a comprehensive review of recent developments in wireless sensor technology for monitoring behaviour related to human physiological responses. It presents background information on the use of wireless technology and sensors to develop a wireless physiological measurement system. A generic miniature platform and other available technologies for wireless sensors have been studied in terms of hardware and software structural requirements for a low-cost, low-power, non-invasive and unobtrusive system.

  10. The Effects of Group Monitoring on Fatigue-Related Einstellung during Mathematical Problem Solving

    ERIC Educational Resources Information Center

    Frings, Daniel

    2011-01-01

    Fatigue resulting from sleep deficit can lead to decreased performance in a variety of cognitive domains and can result in potentially serious accidents. The present study aimed to test whether fatigue leads to increased Einstellung (low levels of cognitive flexibility) in a series of mathematical problem-solving tasks. Many situations involving…

  11. The Main Concept Analysis in Cantonese Aphasic Oral Discourse: External Validation and Monitoring Chronic Aphasia

    ERIC Educational Resources Information Center

    Kong, Anthony Pak-Hin

    2011-01-01

    Purpose: The 1st aim of this study was to further establish the external validity of the main concept (MC) analysis by examining its relationship with the Cantonese Linguistic Communication Measure (CLCM; Kong, 2006; Kong & Law, 2004)--an established quantitative system for narrative production--and the Cantonese version of the Western Aphasia…

  12. From the Learning Diary to the ELP: An E-Portfolio for Autonomous Language Learning

    ERIC Educational Resources Information Center

    Bertolotti, Greta; Beseghi, Micol

    2016-01-01

    In 2011 the Language Centre of the University of Parma introduced a self-study programme aimed at creating an autonomy-inspired language learning environment. Students are actively engaged in the management of their own learning and co-directed by advisors and teachers in the phases of planning, monitoring and assessment. Reflective diary writing…

  13. Longitudinal Associations between Adolescent Alcohol Use and Parents' Sources of Knowledge

    ERIC Educational Resources Information Center

    Stavrinides, Panayiotis; Georgiou, Stelios; Demetriou, Andreas

    2010-01-01

    The aim of this study was to test the direction of effect in the relationship between parents' sources of knowledge (parental monitoring and child disclosure) and adolescent alcohol use. The participants were 215 adolescents and their mothers, randomly selected from urban and rural areas in Cyprus. A 3-month, two-timepoint longitudinal design was…

  14. Relationship between Self-Reflectivity, Theory of Mind, Neurocognition, and Global Functioning: An Investigation of Schizophrenic Disorder

    ERIC Educational Resources Information Center

    Giusti, Laura; Mazza, Monica; Pollice, Rocco; Casacchia, Massimo; Roncone, Rita

    2013-01-01

    Background: People with schizophrenia show impairments in metacognitive function, including awareness and monitoring of one's mental processes (Self-Reflectivity (SR)), recognition of the fallibility of one's thoughts, and the ability to infer others' emotions and intentions (Theory of Mind (ToM)). The aim of the present study was to explore…

  15. Monitoring Ambulation of Patients in Geriatric Rehabilitation Wards: The Accuracy of Clinicians' Prediction of Patients' Walking Time

    ERIC Educational Resources Information Center

    Cheung, Vivian H. Y.; Salih, Salih A.; Crouch, Alisa; Karunanithi, Mohanraj K.; Gray, Len

    2012-01-01

    The aim of this study is to determine whether clinicians' estimates of patients' walking time agree with those determined by accelerometer devices. The walking time was measured using a waist-mounted accelerometer device everyday during the patients' waking hours. At each weekly meeting, clinicians estimated the patients' average daily walking…

  16. Critical Neural Substrates for Correcting Unexpected Trajectory Errors and Learning from Them

    ERIC Educational Resources Information Center

    Mutha, Pratik K.; Sainburg, Robert L.; Haaland, Kathleen Y.

    2011-01-01

    Our proficiency at any skill is critically dependent on the ability to monitor our performance, correct errors and adapt subsequent movements so that errors are avoided in the future. In this study, we aimed to dissociate the neural substrates critical for correcting unexpected trajectory errors and learning to adapt future movements based on…

  17. The Contribution of International Large-Scale Assessments to Educational Research: Combining Individual and Institutional Data Sources

    ERIC Educational Resources Information Center

    Strietholt, Rolf; Scherer, Ronny

    2018-01-01

    The present paper aims to discuss how data from international large-scale assessments (ILSAs) can be utilized and combined, even with other existing data sources, in order to monitor educational outcomes and study the effectiveness of educational systems. We consider different purposes of linking data, namely, extending outcomes measures,…

  18. Is There a Role for Educational Psychologists in Facilitating Managed Moves?

    ERIC Educational Resources Information Center

    Bagley, Christopher; Hallam, Susan

    2017-01-01

    The current research aimed to explore the extent to which school professionals and local authority staff perceived that there was a role for educational psychologists in the processes involved in implementing, monitoring and offering support to young people for whom a managed move was being arranged. The study was conducted in one English local…

  19. Transitioning in Higher Education: An Exploration of Psychological and Contextual Factors Affecting Student Satisfaction

    ERIC Educational Resources Information Center

    Pennington, Charlotte R.; Bates, Elizabeth A.; Kaye, Linda K.; Bolam, Lauren T.

    2018-01-01

    In view of recent changes in the higher education sector, such as increased tuition fees, a greater focus has been placed on widening participation initiatives and monitoring student satisfaction. The aims of the current study were twofold: (1) to explore whether pre-entry programmes foster successful transition to higher education, and (2) to…

  20. FRAMEWORK FOR STRUCTURAL ONLINE HEALTH MONITORING OF AGING AND DEGRADATION OF SECONDARY PIPING SYSTEMS DUE TO SOME ASPECTS OF EROSION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gribok, Andrei V.; Agarwal, Vivek

    This paper describes the current state of research related to critical aspects of erosion and selected aspects of degradation of secondary components in nuclear power plants (NPPs). The paper also proposes a framework for online health monitoring of aging and degradation of secondary components. The framework consists of an integrated multi-sensor modality system, which can be used to monitor different piping configurations under different degradation conditions. The report analyses the currently known degradation mechanisms and available predictive models. Based on this analysis, the structural health monitoring framework is proposed. The Light Water Reactor Sustainability Program began to evaluate technologies thatmore » could be used to perform online monitoring of piping and other secondary system structural components in commercial NPPs. These online monitoring systems have the potential to identify when a more detailed inspection is needed using real time measurements, rather than at a pre-determined inspection interval. This transition to condition-based, risk-informed automated maintenance will contribute to a significant reduction of operations and maintenance costs that account for the majority of nuclear power generation costs. Furthermore, of the operations and maintenance costs in U.S. plants, approximately 80% are labor costs. To address the issue of rising operating costs and economic viability, in 2017, companies that operate the national nuclear energy fleet started the Delivering the Nuclear Promise Initiative, which is a 3 year program aimed at maintaining operational focus, increasing value, and improving efficiency. There is unanimous agreement between industry experts and academic researchers that identifying and prioritizing inspection locations in secondary piping systems (for example, in raw water piping or diesel piping) would eliminate many excessive in-service inspections. The proposed structural health monitoring framework takes aim at answering this challenge by combining long range guided wave technologies with other monitoring techniques, which can significantly increase the inspection length and pinpoint the locations that degraded the most. More widely, the report suggests research efforts aimed at developing, validating, and deploying online corrosion monitoring techniques for complex geometries, which are pervasive in NPPs.« less

  1. Effects of computer monitor-emitted radiation on oxidant/antioxidant balance in cornea and lens from rats

    PubMed Central

    Namuslu, Mehmet; Devrim, Erdinç; Durak, İlker

    2009-01-01

    Purpose This study aims to investigate the possible effects of computer monitor-emitted radiation on the oxidant/antioxidant balance in corneal and lens tissues and to observe any protective effects of vitamin C (vit C). Methods Four groups (PC monitor, PC monitor plus vitamin C, vitamin C, and control) each consisting of ten Wistar rats were studied. The study lasted for three weeks. Vitamin C was administered in oral doses of 250 mg/kg/day. The computer and computer plus vitamin C groups were exposed to computer monitors while the other groups were not. Malondialdehyde (MDA) levels and superoxide dismutase (SOD), glutathione peroxidase (GSH-Px), and catalase (CAT) activities were measured in corneal and lens tissues of the rats. Results In corneal tissue, MDA levels and CAT activity were found to increase in the computer group compared with the control group. In the computer plus vitamin C group, MDA level, SOD, and GSH-Px activities were higher and CAT activity lower than those in the computer and control groups. Regarding lens tissue, in the computer group, MDA levels and GSH-Px activity were found to increase, as compared to the control and computer plus vitamin C groups, and SOD activity was higher than that of the control group. In the computer plus vitamin C group, SOD activity was found to be higher and CAT activity to be lower than those in the control group. Conclusion The results of this study suggest that computer-monitor radiation leads to oxidative stress in the corneal and lens tissues, and that vitamin C may prevent oxidative effects in the lens. PMID:19960068

  2. 6(th) Annual Symposium on Self-Monitoring of Blood Glucose (SMBG) applications and beyond, April 25-27, 2013, Riga, Latvia.

    PubMed

    Alzaid, Aus; Schlaeger, Christof; Hinzmann, Rolf

    2013-12-01

    International experts in the fields of diabetes, diabetes technology, endocrinology, and pediatrics gathered for the 6(th) Annual Symposium on Self-Monitoring of Blood Glucose (SMBG) Applications and beyond. The aim of this meeting was to continue setting up a global network of experts in this field and provide an international platform for exchange of ideas to improve life for people with diabetes. The 2013 meeting comprised a comprehensive scientific program, parallel interactive workshops, and two keynote lectures. All these discussions were intended to help identify gaps and areas where further scientific work and clinical studies are warranted.

  3. A guide to processing bat acoustic data for the North American Bat Monitoring Program (NABat)

    USGS Publications Warehouse

    Reichert, Brian; Lausen, Cori; Loeb, Susan; Weller, Ted; Allen, Ryan; Britzke, Eric; Hohoff, Tara; Siemers, Jeremy; Burkholder, Braden; Herzog, Carl; Verant, Michelle

    2018-06-14

    The North American Bat Monitoring Program (NABat) aims to improve the state of conservation science for all species of bats shared by the United States, Canada, and Mexico. To accomplish this goal, NABat offers guidance and standardized protocols for acoustic monitoring of bats. In this document, “A Guide to Processing Bat Acoustic Data for the North American Bat Monitoring Program (NABat),” we provide general recommendations and specific workflows for the process of identifying bat species from acoustic files recorded using the NABat stationary point and mobile transect acoustic monitoring protocols.

  4. Detection of physical activities using a physical activity monitor system for wheelchair users.

    PubMed

    Hiremath, Shivayogi V; Intille, Stephen S; Kelleher, Annmarie; Cooper, Rory A; Ding, Dan

    2015-01-01

    Availability of physical activity monitors for wheelchair users can potentially assist these individuals to track regular physical activity (PA), which in turn could lead to a healthier and more active lifestyle. Therefore, the aim of this study was to develop and validate algorithms for a physical activity monitoring system (PAMS) to detect wheelchair based activities. The PAMS consists of a gyroscope based wheel rotation monitor (G-WRM) and an accelerometer device (wocket) worn on the upper arm or on the wrist. A total of 45 persons with spinal cord injury took part in the study, which was performed in a structured university-based laboratory environment, a semi-structured environment at the National Veterans Wheelchair Games, and in the participants' home environments. Participants performed at least ten PAs, other than resting, taken from a list of PAs. The classification performance for the best classifiers on the testing dataset for PAMS-Arm (G-WRM and wocket on upper arm) and PAMS-Wrist (G-WRM and wocket on wrist) was 89.26% and 88.47%, respectively. The outcomes of this study indicate that multi-modal information from the PAMS can help detect various types of wheelchair-based activities in structured laboratory, semi-structured organizational, and unstructured home environments. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  5. Liquid-containing Refluxes and Acid Refluxes May Be Less Frequent in the Japanese Population Than in Other Populations: Normal Values of 24-hour Esophageal Impedance and pH Monitoring

    PubMed Central

    Kawamura, Osamu; Kohata, Yukie; Kawami, Noriyuki; Iida, Hiroshi; Kawada, Akiyo; Hosaka, Hiroko; Shimoyama, Yasuyuki; Kuribayashi, Shiko; Fujiwara, Yasuhiro; Iwakiri, Katsuhiko; Inamori, Masahiko; Kusano, Motoyasu; Hongo, Micho

    2016-01-01

    Background/Aims Twenty-four-hour esophageal impedance and pH monitoring allows detection of all types of reflux episodes and is considered the best technique for identifying gastroesophageal refluxes. However, normative data for the Japanese population are lacking. This multicenter study aimed to establish the normal range of 24-hour esophageal impedance and pH data both in the distal and the proximal esophagus in Japanese subjects. Methods Forty-two healthy volunteers (25 men and 17 women) with a mean ± standard deviation age of 33.3 ± 12.4 years (range: 22–72 years) underwent a combined 24-hour esophageal impedance and pH monitoring. According to the physical and pH properties, distal or proximal esophageal reflux events were categorized. Results Median 45 reflux events occurred in 24 hours, and the 95th percentile was 85 events. Unlike previous reports, liquid-containing reflux events are median 25/24 hours with the 95th percentile of 62/24 hours. Acidic reflux events were median 11/24 hours with the 95th percentile of 39/24 hours. Non-acidic gas reflux events were median 15/24 hours with the 95th percentile of 39/24 hours. Proximal reflux events accounted for 80% of the total reflux events and were mainly non-acidic gas refluxes. About 19% of liquid and mixed refluxes reached the proximal esophagus. Conclusions Unlike previous studies, liquid-containing and acidic reflux events may be less frequent in the Japanese population. Non-acidic gas reflux events may be frequent and a cause of frequent proximal reflux events. This study provides important normative data for 24-hour impedance and pH monitoring in both the distal and the proximal esophagus in the Japanese population. PMID:27247103

  6. Comparative analysis of three different methods for monitoring the use of green bridges by wildlife.

    PubMed

    Gužvica, Goran; Bošnjak, Ivana; Bielen, Ana; Babić, Danijel; Radanović-Gužvica, Biserka; Šver, Lidija

    2014-01-01

    Green bridges are used to decrease highly negative impact of roads/highways on wildlife populations and their effectiveness is evaluated by various monitoring methods. Based on the 3-year monitoring of four Croatian green bridges, we compared the effectiveness of three indirect monitoring methods: track-pads, camera traps and active infrared (IR) trail monitoring system. The ability of the methods to detect different species and to give good estimation of number of animal crossings was analyzed. The accuracy of species detection by track-pad method was influenced by granulometric composition of track-pad material, with the best results obtained with higher percentage of silt and clay. We compared the species composition determined by track-pad and camera trap methods and found that monitoring by tracks underestimated the ratio of small canids, while camera traps underestimated the ratio of roe deer. Regarding total number of recorder events, active IR detectors recorded from 11 to 19 times more events then camera traps and app. 80% of them were not caused by animal crossings. Camera trap method underestimated the real number of total events. Therefore, an algorithm for filtration of the IR dataset was developed for approximation of the real number of crossings. Presented results are valuable for future monitoring of wildlife crossings in Croatia and elsewhere, since advantages and disadvantages of used monitoring methods are shown. In conclusion, different methods should be chosen/combined depending on the aims of the particular monitoring study.

  7. Representativeness of shorter measurement sessions in long-term indoor air monitoring.

    PubMed

    Maciejewska, M; Szczurek, A

    2015-02-01

    Indoor air quality (IAQ) considerably influences health, comfort and the overall performance of people who spend most of their lives in confined spaces. For this reason, there is a strong need to develop methods for IAQ assessment. The fundamental issue in the quantitative determination of IAQ is the duration of measurements. Its inadequate choice may result in providing incorrect information and this potentially leads to wrong conclusions. The most complete information may be acquired through long-term monitoring. However it is typically perceived as impractical due to time and cost load. The aim of this study was to determine whether long-term monitoring can be adequately represented by a shorter measurement session. There were considered three measurable quantities: temperature, relative humidity and carbon dioxide concentration. They are commonly recognized as indicatives for IAQ and may be readily monitored. Scaled Kullback-Leibler divergence, also called relative entropy, was applied as a measure of data representativeness. We considered long-term monitoring in a range from 1 to 9 months. Based on our work, the representative data on CO2 concentration may be acquired while performing measurements during 20% of time dedicated to long-term monitoring. In the case of temperature and relative humidity the respective time demand was 50% of long-term monitoring. From our results, in indoor air monitoring strategies, there could be considered shorter measurement sessions, while still collecting data which are representative for long-term monitoring.

  8. [DIFFERENT APPROACHES FOR CHEMICAL RISK ASSESSMENT IN LABORATORIES].

    PubMed

    Caporossi, Lidia; Papaleo, Bruno; Capanna, Silvia; Calicchia, Sara; Marcellini, Laura; De Rosa, Mariangela; Castellano, Paola

    2015-01-01

    The aim of this study was to compare the different approaches used for chemical risk assessment, in relation to the perception of riskfor operators, in some research laboratories of a hospital in Rome. All information regarding the chemicals used for the application of three algorithmic models for chemical risk assessment ("Movarisch", "Inforisk", "Archimede") were collected. An environmental and biological monitoring and a study on the combined exposure to multiple chemicals using the World Health Organization proposed steps were carried out. A questionnaire was prepared for the identification of risk perception. An estimation of chemical risk with algorithms was compared with data from monitoring: findings showed that estimated risk was higher than those identified with airborne or urine concentrations, always under their limit values. The study of multiple exposure showed a possible cumulative risk, in some cases, but the conditions of use (volume and time) often bring to a reduced one. The perception of risk attributed to the monitored hazardous substances showed a correct perception in all laboratories and for all workers, with regard to the substances manipulated.

  9. Automatized Photometric Monitoring of Active Galactic Nuclei with the 46cm Telescope of the Wise Observatory

    NASA Astrophysics Data System (ADS)

    Pozo Nuñez, Francisco; Chelouche, Doron; Kaspi, Shai; Niv, Saar

    2017-09-01

    We present the first results of an ongoing variability monitoring program of active galactic nuclei (AGNs) using the 46 cm telescope of the Wise Observatory in Israel. The telescope has a field of view of 1.25^\\circ × 0.84^\\circ and is specially equipped with five narrowband filters at 4300, 5200, 5700, 6200, and 7000 Å to perform photometric reverberation mapping studies of the central engine of AGNs. The program aims to observe a sample of 27 AGNs (V < 17 mag) selected according to tentative continuum and line time delay measurements obtained in previous works. We describe the autonomous operation of the telescope together with the fully automatic pipeline used to achieve high-performance unassisted observations, data reduction, and light curves extraction using different photometric methods. The science verification data presented here demonstrates the performance of the monitoring program in particular for efficiently photometric reverberation mapping of AGNs with additional capabilities to carry out complementary studies of other transient and variable phenomena such as variable stars studies.

  10. The Emerging Wireless Body Area Network on Android Smartphones: A Review

    NASA Astrophysics Data System (ADS)

    Puspitaningayu, P.; Widodo, A.; Yundra, E.

    2018-01-01

    Our society now has driven us into an era where almost everything can be digitally monitored and controlled including the human body. The growth of wireless body area network (WBAN), as a specific scope of sensor networks which mounted or attached to human body also developing rapidly. It allows people to monitor their health and several daily activities. This study is intended to review the trend of WBAN especially on Android, one of the most popular smartphone platforms. A systematic literature review is concerned to the following parameters: the purpose of the device and/or application, the type of sensors, the type of Android device, and its connectivity. Most of the studies were more concern to healthcare or medical monitoring systems: blood pressure, electro cardiograph, tremor detection, etc. On the other hand, the rest of them aimed for activity tracker, environment sensing, and epidemic control. After all, those studies shown that not only Android can be a powerful platform to process data from various sensors but also smartphones can be a good alternative to develop WBANs for medical and other daily applications.

  11. Are vital signs indicative for bacteremia in newborns?

    PubMed

    Yapıcıoğlu, Hacer; Özlü, Ferda; Sertdemir, Yaşar

    2015-01-01

    Neonatal systemic infection is a leading cause of morbidity and mortality both in industrialized and developing countries. The aim of this prospective study was to evaluate if vital signs had a predictive power in neonatal sepsis as an early marker. This study was designed as a matched case-control study. Vital signs were monitorized prior to infection in newborns that had healthcare-associated blood stream infection (BSI). Maximum and minimum values of the vital signs (blood pressure, heart rate, respiratory rate and temperature) of the babies at rest were recorded from the nurse observation charts five days prior to clinical sepsis and compared with vital signs of healthy, age-matched babies. Maximum mean heart rates, respiratory rates and systolic blood pressure levels of the patients in BSI group were significantly higher than the control group in the past three days prior to clinical deterioration. Monitoring vital signs closely might be helpful in a newborn infant to define a BSI. In future, a respiratory and blood pressure predictive monitoring system such as heart rate variability index may be developed for newborn patients with sepsis.

  12. Vibrio Species in Wastewater Final Effluents and Receiving Watershed in South Africa: Implications for Public Health.

    PubMed

    Okeyo, Allisen N; Nontongana, Nolonwabo; Fadare, Taiwo O; Okoh, Anthony I

    2018-06-15

    Wastewater treatment facilities in South Africa are obliged to make provision for wastewater effluent quality management, with the aim of securing the integrity of the surrounding watersheds and environments. The Department of Water Affairs has documented regulatory parameters that have, over the years, served as a guideline for quality monitoring/management purposes. However, these guidelines have not been regularly updated and this may have contributed to some of the water quality anomalies. Studies have shown that promoting the monitoring of the current routinely monitored parameters (both microbial and physicochemical) may not be sufficient. Organisms causing illnesses or even outbreaks, such as Vibrio pathogens with their characteristic environmental resilience, are not included in the guidelines. In South Africa, studies that have been conducted on the occurrence of Vibrio pathogens in domestic and wastewater effluent have made it apparent that these pathogens should also be monitored. The importance of effective wastewater management as one of the key aspects towards protecting surrounding environments and receiving watersheds, as well as protecting public health, is highlighted in this review. Emphasis on the significance of the Vibrio pathogen in wastewater is a particular focus.

  13. Environmental microbial contamination in a stem cell bank.

    PubMed

    Cobo, F; Concha, A

    2007-04-01

    The aim of this study was to evaluate the main environmental microbial contaminants of the clean rooms in our stem cell bank. We have measured the microbial air contamination by both passive and active air sampling and the microbial monitoring of surfaces by means of Rodac plates. The environmental monitoring tests were carried out in accordance with the guidelines of European Pharmacopeia and US Pharmacopeia. The micro-organisms were identified by means of an automated system (VITEK 2). During the monitoring, the clean rooms are continually under good manufacturing practices specifications. The most frequent contaminants were Gram-positive cocci. The main contaminants in our stem cell bank were coagulase-negative staphylococci and other opportunistic human pathogens. In order to assure the levels of potential contamination in both embryonic and adult stem cell lines, a continuous sampling of air particles and testing for viable microbiological contamination is necessary. This study is the first evaluation of the environmental contaminants in stem cell banks and can serve as initial evaluation for these establishments. The introduction of environmental monitoring programmes in the processing of stem cell lines could diminish the risk of contamination in stem cell cultures.

  14. Intelligent monitoring of Aedes aegypti in a rural area of Rio de Janeiro State, Brazil

    PubMed Central

    Sanavria, Argemiro; da Silva, Claudia Bezerra; Electo, Érica Heleno; Nogueira, Lidiane Cristina Rocha; Thomé, Sandra Maria Gomes; Angelo, Isabele da Costa; Vita, Gilmar Ferreira; Sanavria, Talles Eduardo Cabral; Padua, Elisa Domingues; Gaiotte, Denise Glória

    2017-01-01

    ABSTRACT The aim of this research was to monitor the presence of females of Aedes aegypti (Linnaeus, 1762) on the Seropédica municipality, Rio de Janeiro State, from 2010 to 2013. For this purpose, the Intelligent Dengue Monitoring (IM-Dengue) and Intelligent Virus Monitoring (IM-Virus) developed by Universidade Federal de Minas Gerais (Ecovec – Minas Gerais, Brazil), were used. IM-Dengue is a tool that allows achieving a weekly overview of A. aegypti infestation, while IM-Virus is another tool that allows detecting dengue virus directly from the mosquito, by Real Time-PCR. Both tools were developed for diagnosis in a prepathogenesis period of the disease, before infection occurrence. Traps were distributed in 19 locations inside the municipality and the bugs were collected weekly during the years of the research. As a result, the presence of 163 females of A. aegypti was recorded over the period; there was no circulation of the virus in the municipality. In one of the 19 study sites, a high degree of disease transmission risk was verified. The study concluded that the municipality, as a whole, showed no risk of disease transmission throughout the field research period. PMID:28793020

  15. Efficacy of Monitoring Patient’s Position during Neurosurgical Procedures: Introduction of Real-time Display and Record

    PubMed Central

    HASEGAWA, Mitsuhiro; NOURI, Mohsen; FUJISAWA, Hironori; HAYASHI, Yutaka; INAMASU, Joji; HIROSE, Yuichi; YAMASHITA, Junkoh

    2015-01-01

    There are many reports on position-related complications in neurosurgical literature but so far, continuous quantification of the patient’s position during the surgery has not been reported. This study aims to explore the utility of a new surgical table system and its software in displaying the patient’s body positions during surgery on real-time basis. More than 200 neurosurgical cases were monitored for their positions intra-operatively. The position was digitally recorded and could be seen by all the members in the operating team. It also displayed the three-dimensional relationship between the head and the heart positions. No position-related complications were observed during the study. The system was able to serve as an excellent indicator for monitoring the patient’s position. The recordings were analyzed and even used to reproduce or improve the position in the subsequent operations. The novel technique of monitoring the position of the head and the heart of the patients and the operating table planes are considered to be useful during delicate neurosurgical procedures thereby, preventing inadvertent procedural errors. This can be used to quantify various surgical positions in the future and define safety measures accordingly. PMID:25797776

  16. Ten years of preanalytical monitoring and control: Synthetic Balanced Score Card Indicator

    PubMed Central

    López-Garrigós, Maite; Flores, Emilio; Santo-Quiles, Ana; Gutierrez, Mercedes; Lugo, Javier; Lillo, Rosa; Leiva-Salinas, Carlos

    2015-01-01

    Introduction Preanalytical control and monitoring continue to be an important issue for clinical laboratory professionals. The aim of the study was to evaluate a monitoring system of preanalytical errors regarding not suitable samples for analysis, based on different indicators; to compare such indicators in different phlebotomy centres; and finally to evaluate a single synthetic preanalytical indicator that may be included in the balanced scorecard management system (BSC). Materials and methods We collected individual and global preanalytical errors in haematology, coagulation, chemistry, and urine samples analysis. We also analyzed a synthetic indicator that represents the sum of all types of preanalytical errors, expressed in a sigma level. We studied the evolution of those indicators over time and compared indicator results by way of the comparison of proportions and Chi-square. Results There was a decrease in the number of errors along the years (P < 0.001). This pattern was confirmed in primary care patients, inpatients and outpatients. In blood samples, fewer errors occurred in outpatients, followed by inpatients. Conclusion We present a practical and effective methodology to monitor unsuitable sample preanalytical errors. The synthetic indicator results summarize overall preanalytical sample errors, and can be used as part of BSC management system. PMID:25672466

  17. Efficacy of monitoring patient's position during neurosurgical procedures: introduction of real-time display and record.

    PubMed

    Hasegawa, Mitsuhiro; Nouri, Mohsen; Fujisawa, Hironori; Hayashi, Yutaka; Inamasu, Joji; Hirose, Yuichi; Yamashita, Junkoh

    2015-01-01

    There are many reports on position-related complications in neurosurgical literature but so far, continuous quantification of the patient's position during the surgery has not been reported. This study aims to explore the utility of a new surgical table system and its software in displaying the patient's body positions during surgery on real-time basis. More than 200 neurosurgical cases were monitored for their positions intra-operatively. The position was digitally recorded and could be seen by all the members in the operating team. It also displayed the three-dimensional relationship between the head and the heart positions. No position-related complications were observed during the study. The system was able to serve as an excellent indicator for monitoring the patient's position. The recordings were analyzed and even used to reproduce or improve the position in the subsequent operations. The novel technique of monitoring the position of the head and the heart of the patients and the operating table planes are considered to be useful during delicate neurosurgical procedures thereby, preventing inadvertent procedural errors. This can be used to quantify various surgical positions in the future and define safety measures accordingly.

  18. Gastro-oesophageal reflux in patients with chronic rhino-sinusitis investigated with multichannel impedance - pH monitoring.

    PubMed

    Katle, E J; Hatlebakk, J G; Grimstad, T; Kvaløy, J T; Steinsvåg, S K

    2017-03-01

    The pathophysiology of chronic rhinosinusitis (CRS) is unclear. It has been discussed for decades whether gastro-oesophageal reflux (GOR) may be a contributing factor for some patients. The aim of the present study was to evaluate the level of GOR in an unselected group of patients with CRS using multichannel impedance-pH monitoring. Consecutive patients with CRS diagnosed using the EPOS2012 criteria, completed questionnaires on GOR symptoms and were offered 24-h multichannel intraluminal impedance (MII)-pH monitoring. The results were compared with a group of healthy controls. Forty-six patients completed MII-pH-monitoring and were compared with 45 control subjects, with comparable age and gender distributions. The median number of reflux episodes in the patients was 56.5 compared with 33 in controls, while, the numbers of proximal reflux episodes was 27.5 versus 3, respectively. Thirty nine patients had abnormal pH-impedance recordings compared with five controls. The CRS patients had significantly higher incidences of gastro-oesophageal reflux compared with asymptomatic controls. The results of this study suggest that GOR may be a causative or contributing factor of CRS.

  19. Electrical engineering support of telemetered traffic monitoring sites : final report, March 2009.

    DOT National Transportation Integrated Search

    2009-03-01

    "The aim of this project was to provide electrical engineering support for the telemetered traffic monitoring sites (TTMS) operated by the Statistics Office of the Florida Department of Transportation. This project was a companion to project BD-543-1...

  20. Civil engineering support for the traffic monitoring program : final report, January 2010.

    DOT National Transportation Integrated Search

    2010-01-01

    This project was aimed at providing various civil engineering support services for the telemetered traffic monitoring sites operated by the Statistics Office of the Florida Department of Transportation. This was a companion project to the one that pr...

  1. Combining model based and data based techniques in a robust bridge health monitoring algorithm.

    DOT National Transportation Integrated Search

    2014-09-01

    Structural Health Monitoring (SHM) aims to analyze civil, mechanical and aerospace systems in order to assess : incipient damage occurrence. In this project, we are concerned with the development of an algorithm within the : SHM paradigm for applicat...

  2. An adaptive field detection method for bridge scour monitoring using motion-sensing radio transponders (RFIDs).

    DOT National Transportation Integrated Search

    2014-01-01

    A comprehensive field detection method is proposed that is aimed at developing advanced capability for : reliable monitoring, inspection and life estimation of bridge infrastructure. The goal is to utilize Motion-Sensing Radio Transponders (RFIDS) on...

  3. Wireless Sensor Network Based Subsurface Contaminant Plume Monitoring

    DTIC Science & Technology

    2012-04-16

    Sensor Network (WSN) to monitor contaminant plume movement in naturally heterogeneous subsurface formations to advance the sensor networking based...time to assess the source and predict future plume behavior. This proof-of-concept research aimed at demonstrating the use of an intelligent Wireless

  4. A continuous glucose monitoring and problem-solving intervention to change physical activity behavior in women with type 2 diabetes: a pilot study.

    PubMed

    Allen, Nancy; Whittemore, Robin; Melkus, Gail

    2011-11-01

    Diabetes technology has the potential to provide useful data for theory-based behavioral counseling. The aims of this study are to evaluate the feasibility, acceptability, and preliminary efficacy of a continuous glucose monitoring and problem-solving counseling intervention to change physical activity (PA) behavior in women with type 2 diabetes. Women (n=29) with type 2 diabetes were randomly assigned to one of two treatment conditions: continuous glucose counseling and problem-solving skills or continuous glucose monitoring counseling and general diabetes education. Feasibility data were obtained on intervention dose, implementation, and satisfaction. Preliminary efficacy data were collected at baseline and 12 weeks on the following measures: PA amount and intensity, diet, problem-solving skills, self-efficacy for PA, depression, hemogoloin A1c, weight, and blood pressure. Demographic and implementation variables were described using frequency distributions and summary statistics. Satisfaction data were analyzed using Wilcoxon rank. Differences between groups were analyzed using linear mixed-modeling. Women were mostly white/non-Latina with a mean age of 53 years, a 6.5-year history of diabetes, and suboptimal glycemic control. Continuous glucose monitoring plus problem-solving group participants had significantly greater problem-solving skills and had greater, although not statistically significant, dietary adherence, moderate activity minutes, weight loss, and higher intervention satisfaction pre- to post-intervention than did participants in the continuous glucose monitoring plus education group. A continuous glucose monitoring plus problem-solving intervention was feasible and acceptable, and participants had greater problem-solving skills than continuous glucose monitoring plus education group participants.

  5. The economic costs of routine INR monitoring in infants and children--examining point-of-care devices used within the home setting compared to traditional anticoagulation clinic monitoring.

    PubMed

    Gaw, James R; Crowley, Steven; Monagle, Paul; Jones, Sophie; Newall, Fiona

    2013-07-01

    The use of point-of-care (POC) devices within the home for routine INR monitoring has demonstrated reliability, safety and effectiveness in the management of infants and children requiring long-term warfarin therapy. However, a comprehensive cost-analysis of using this method of management, compared to attending anticoagulation clinics has not been reported. The aim of this study was to compare the estimated societal costs of attending anticoagulation clinics for routine INR monitoring to using a POC test in the home. This study used a comparative before-and-after design that included 60 infants and children managed via the Haematology department at a tertiary paediatric centre. Each participant was exposed to both modes of management at various times for a period of ≥3 months. A questionnaire, consisting of 25 questions was sent to families to complete and return. Data collected included: the frequency of monitoring, mode of travel to and from clinics, total time consumed, and primary carer's income level. The home monitoring cohort saved a total of 1 hour 19 minutes per INR test compared to attending anticoagulation clinics and had a cost saving to society of $66.83 (AUD) per INR test compared to traditional care; incorporating health sector costs, travel expenses and lost time. The traditional model of care requires a considerable investment of time per test from both child and carer. Home INR monitoring in infants and children provides greater societal economic benefits compared to traditional models. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Optimal ergonomics for laparoscopic surgery in minimally invasive surgery suites: a review and guidelines.

    PubMed

    van Det, M J; Meijerink, W J H J; Hoff, C; Totté, E R; Pierie, J P E N

    2009-06-01

    With minimally invasive surgery (MIS), a man-machine environment was brought into the operating room, which created mental and physical challenges for the operating team. The science of ergonomics analyzes these challenges and formulates guidelines for creating a work environment that is safe and comfortable for its operators while effectiveness and efficiency of the process are maintained. This review aimed to formulate the ergonomic challenges related to monitor positioning in MIS. Background and guidelines are formulated for optimal ergonomic monitor positioning within the possibilities of the modern MIS suite, using multiple monitors suspended from the ceiling. All evidence-based experimental ergonomic studies conducted in the fields of laparoscopic surgery and applied ergonomics for other professions working with a display were identified by PubMed searches and selected for quality and applicability. Data from ergonomic studies were evaluated in terms of effectiveness and efficiency as well as comfort and safety aspects. Recommendations for individual monitor positioning are formulated to create a personal balance between these two ergonomic aspects. Misalignment in the eye-hand-target axis because of limited freedom in monitor positioning is recognized as an important ergonomic drawback during MIS. Realignment of the eye-hand-target axis improves personal values of comfort and safety as well as procedural values of effectiveness and efficiency. Monitor position is an important ergonomic factor during MIS. In the horizontal plain, the monitor should be straight in front of each person and aligned with the forearm-instrument motor axis to avoid axial rotation of the spine. In the sagittal plain, the monitor should be positioned lower than eye level to avoid neck extension.

  7. Effectiveness of a simple and real-time baseline shift monitoring system during stereotactic body radiation therapy of lung tumors.

    PubMed

    Uchida, Yukihiro; Tachibana, Hidenobu; Kamei, Yoshiyuki; Kashihara, Kenichi

    2017-11-01

    This study aimed to clinically validate a simple real-time baseline shift monitoring system in a prospective study of consecutive patients undergoing stereotactic body radiation therapy (SBRT) of lung tumors, and to investigate baseline shift due to intrafraction motion of the patient's body during lung SBRT. Ten consecutive patients with peripheral lung tumors were treated by SBRT consisting of four fractions of 12 Gy each, with a total dose of 48 Gy. During treatment, each patient's geometric displacement in the anterior-posterior and left-right directions (the baseline shift) was measured using a real-time monitoring webcam system. Displacement between the start and end of treatment was measured using an X-ray fluoroscopic imaging system. The displacement measurements of the two systems were compared, and the measurements of baseline shift acquired by the monitoring system during treatment were analyzed for all patients. There was no significant deviation between the monitoring system and the X-ray imaging system, with the accuracy of measurement being within 1 mm. Measurements using the monitoring system showed that 7 min of treatment generated displacements of more than 1 mm in 50% of the patients. Baseline shift of a patient's body may be measured accurately in real time, using a monitoring system without X-ray exposure. The manubrium of the sternum is a good location for measuring the baseline shift of a patient's body at all times. The real-time monitoring system may be useful for measuring the baseline shift of a patient's body independently of a gating system. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  8. Inconsistency in the Diagnosis of Functional Heartburn: Usefulness of Prolonged Wireless pH Monitoring in Patients With Proton Pump Inhibitor Refractory Gastroesophageal Reflux Disease

    PubMed Central

    Penagini, Roberto; Sweis, Rami; Mauro, Aurelio; Domingues, Gerson; Vales, Andres; Sifrim, Daniel

    2015-01-01

    Background/Aims The diagnosis of functional heartburn is important for management, however it stands on fragile pH monitoring variables, ie, acid exposure time varies from day to day and symptoms are often few or absent. Aim of this study was to investigate consistency of the diagnosis of functional heartburn in subsequent days using prolonged wireless pH monitoring and its impact on patients’ outcome. Methods Fifty proton pump inhibitotor refractory patients (11 male, 48 years [range, 38–57 years]) with a diagnosis of functional heart-burn according to Rome III in the first 24 hours of wireless pH monitoring were reviewed. pH variables were analysed in the following 24-hour periods to determine if tracings were indicative of diagnosis of non-erosive reflux disease (either acid exposure time > 5% or normal acid exposure time and symptom index ≥ 50%). Outcome was assessed by review of hospital files and/or telephone interview. Results Fifteen out of 50 patients had a pathological acid exposure time after the first day of monitoring (10 in the second day and 5 in subsequent days), which changed their diagnosis from functional heartburn to non-erosive reflux disease. Fifty-four percent of non-erosive reflux disease vs 11% of functional heartburn patients (P < 0.003) increased the dose of proton pump inhibitors or underwent fundoplication after the pH test. Outcome was positive in 77% of non-erosive reflux disease vs 43% of functional heartburn patients (P < 0.05). Conclusions One-third of patients classified as functional heartburn at 24-hour pH-monitoring can be re-classified as non-erosive reflux disease after a more prolonged pH recording period. This observation has a positive impact on patients’ management. PMID:25843078

  9. Aeronomy of Ice in the Mesosphere Mission Overview and Collaborative Studies Using the AIM and TIMED Data Sets

    NASA Astrophysics Data System (ADS)

    Rusell, J. M.; Bailey, S. M.; Rusch, D.; Gordley, L. L.; Hervig, M. E.; Merkel, A.

    2007-12-01

    The Aeronomy of Ice in the Mesosphere (AIM) mission was launched from Vandenberg Air Force Base in California on April 25, 2007 becoming the first satellite mission dedicated to the study of noctilucent clouds that occur at approximately 83km altitude. A Pegasus XL rocket launched the satellite into a near perfect 600 km sun synchronous circular orbit. AIM carries three instruments - a nadir imager, a solar occultation instrument and an in-situ cosmic dust detector - that were specifically selected because of their ability to provide key measurements needed to address the six AIM science objectives. The Thermosphere Ionosphere Mesosphere Energetics and Dynamics mission was launched from Vandenberg Air Force Base on December 7, 2001 and is dedicated to the study of the structure, chemistry, energetics and dynamics of the atmospheric region between 60 km and 180 km altitude. TIMED carries four instruments including an infrared limb sounder to characteristic the temperature, chemistry, energetics and dynamics of the region; a global ultraviolet imager; a solar flux monitor and an instrument to measure winds. Together AIM and TIMED form an important component of the Heliophysics Great Observatory. This paper will provide an overview of the AIM mission and will discuss collaborative studies using the combined AIM/TIMED data sets in a synergistic way to advance our knowledge of this region where the sun first interacts with Earth's atmosphere.

  10. The Johns Hopkins RTR Consortium: A Collaborative Approach to Advance Translational Science and Standardize Clinical Monitoring of Restorative Transplantation

    DTIC Science & Technology

    2016-10-01

    non-myeloablative conditioning plus bone marrow infusion (BMI) and intermediate dose tacrolimus (10-15 ng/ml) for 30 days only. Group VIII received the...induction regimen, BMI and CTLA4-Ig and a short-term dose of tacrolimus (30 days ). In all groups, graft rejection was monitored by clinical...long-term graft survival (>230 days ). In the current reporting period (Aim 2 and Aim 3), 3/3 animals in group IV and 4/5 animals in Group V achieved

  11. Analyzing Dental Implant Sites From Cone Beam Computed Tomography Scans on a Tablet Computer: A Comparative Study Between iPad and 3 Display Systems.

    PubMed

    Carrasco, Alejandro; Jalali, Elnaz; Dhingra, Ajay; Lurie, Alan; Yadav, Sumit; Tadinada, Aditya

    2017-06-01

    The aim of this study was to compare a medical-grade PACS (picture archiving and communication system) monitor, a consumer-grade monitor, a laptop computer, and a tablet computer for linear measurements of height and width for specific implant sites in the posterior maxilla and mandible, along with visualization of the associated anatomical structures. Cone beam computed tomography (CBCT) scans were evaluated. The images were reviewed using PACS-LCD monitor, consumer-grade LCD monitor using CB-Works software, a 13″ MacBook Pro, and an iPad 4 using OsiriX DICOM reader software. The operators had to identify anatomical structures in each display using a 2-point scale. User experience between PACS and iPad was also evaluated by means of a questionnaire. The measurements were very similar for each device. P-values were all greater than 0.05, indicating no significant difference between the monitors for each measurement. The intraoperator reliability was very high. The user experience was similar in each category with the most significant difference regarding the portability where the PACS display received the lowest score and the iPad received the highest score. The iPad with retina display was comparable with the medical-grade monitor, producing similar measurements and image visualization, and thus providing an inexpensive, portable, and reliable screen to analyze CBCT images in the operating room during the implant surgery.

  12. Validation of the AVITA BPM64 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Kang, Yuan-Yuan; Chen, Qi; Liu, Chang-Yuan; Li, Yan; Wang, Ji-Guang

    2018-02-01

    The aim of this study was to evaluate the accuracy of the automated oscillometric upper arm blood pressure (BP) monitor AVITA BPM64 for home BP monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic BPs were measured sequentially in 33 adult Chinese (14 women, mean age 47.0 years) using a mercury sphygmomanometer (two observers) and the AVITA BPM64 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The AVITA BPM64 device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 91/99, 98/99, and 98/99, respectively, for systolic BP and 92/99, 99/99, and 99/99, respectively, for diastolic BP. The device also fulfilled the criteria in part 2 of the validation study. Thirty-two participants for both systolic and diastolic BP had at least two of the three device-observer differences within 5 mmHg (required ≥24). Only one participant for systolic BP had all three device-observer comparisons greater than 5 mmHg. The AVITA upper arm BP monitor BPM64 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  13. Development of a seroprevalence map for avian influenza in broiler chickens from Comunidad Valenciana, Spain.

    PubMed

    2014-12-01

    The aim of this study was to design and implement a seroprevalence map based on business intelligence for low pathogenicity notifiable avian influenza (LPNAI) in broilerchickens in Comunidad Valenciana (Spain). The software mapping tool developed for this study consisted of three main phases: data collection, data analysis and data representation. To obtain the serological data, the authors analysed 8,520 serum samples from broiler farms over three years. The data were represented on a map of Comunidad Valenciana, including geographical information of flock locations to facilitate disease monitoring. No clinical signs of LPNAI were reported in the studied flocks. The data from this study showed no evidence of contact with LPNAI in broiler flocks and the novel software mapping tool proved a valuable method for easily monitoring on the serological response to avian influenza information, including geographical information.

  14. Evaluating the Use of Tissue Oximetry to Decrease Intensive Unit Monitoring for Free Flap Breast Reconstruction.

    PubMed

    Ricci, Joseph A; Vargas, Christina R; Ho, Olivia A; Lin, Samuel J; Tobias, Adam M; Lee, Bernard T

    2017-07-01

    Postoperative free flap care has historically required intensive monitoring for 24 hours in an intensive care unit. Continuous monitoring with tissue oximetry has allowed earlier detection of vascular compromise, decreasing flap loss and improving salvage. This study aims to identify whether a fast-track postoperative paradigm can be safely used with tissue oximetry to decrease intensive monitoring and costs. All consecutive microsurgical breast reconstructions performed at a single institution were reviewed (2008-2014) and cases requiring return to the operating room were identified. Data evaluated included patient demographics, the take back time course, and complications of flap loss and salvage. A cost-benefit analysis was performed to analyse the utility of a postoperative intensive monitoring setting. There were 900 flaps performed and 32 required an unplanned return to the operating room. There were 16 flaps that required a reexploration within the first 24 hours; the standard length of intensive unit monitoring. After 4 hours, there were 7 flaps (44%) detected by tissue oximetry for reexploration. After 15 hours of intensive monitoring postoperatively, cost analysis revealed that the majority (15/16; 94%) of failing flaps had been identified and the cost of identifying each subsequent failing flap exceeded the cost of another hour of intensive monitoring. The postoperative paradigm for microsurgical flaps has historically required intensive unit monitoring. Using tissue oximetry, a fast-track pathway can reduce time spent in an intensive monitoring setting from 24 to 15 hours with significant cost savings and minimal risk of missing a failing free flap.

  15. Real-time stress monitoring of highway bridges with a secured wireless sensor network.

    DOT National Transportation Integrated Search

    2011-12-01

    "This collaborative research aims to develop a real-time stress monitoring system for highway bridges with a secured wireless sensor network. The near term goal is to collect wireless sensor data under different traffic patterns from local highway br...

  16. 76 FR 69214 - Approval and Promulgation of Air Quality Implementation Plans; Virginia; Consumer and Commercial...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-08

    ... portable fuel containers, consumer products, architectural and industrial (AIM) coatings, adhesives and... the control technology, testing, monitoring, administrative, recordkeeping, and reporting requirements... and products subject to the standards subject to the provisions of Chapter 45, specify monitoring...

  17. Implementation of evidence-based home visiting programs aimed at reducing child maltreatment: A meta-analytic review.

    PubMed

    Casillas, Katherine L; Fauchier, Angèle; Derkash, Bridget T; Garrido, Edward F

    2016-03-01

    In recent years there has been an increase in the popularity of home visitation programs as a means of addressing risk factors for child maltreatment. The evidence supporting the effectiveness of these programs from several meta-analyses, however, is mixed. One potential explanation for this inconsistency explored in the current study involves the manner in which these programs were implemented. In the current study we reviewed 156 studies associated with 9 different home visitation program models targeted to caregivers of children between the ages of 0 and 5. Meta-analytic techniques were used to determine the impact of 18 implementation factors (e.g., staff selection, training, supervision, fidelity monitoring, etc.) and four study characteristics (publication type, target population, study design, comparison group) in predicting program outcomes. Results from analyses revealed that several implementation factors, including training, supervision, and fidelity monitoring, had a significant effect on program outcomes, particularly child maltreatment outcomes. Study characteristics, including the program's target population and the comparison group employed, also had a significant effect on program outcomes. Implications of the study's results for those interested in implementing home visitation programs are discussed. A careful consideration and monitoring of program implementation is advised as a means of achieving optimal study results. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Real-time monitoring, prognosis, and resilient control for wind turbine systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gao, Zhiwei; Sheng, Shuangwen

    This special issue aims to provide a platform for academic and industrial communities to report recent results and emerging research in real-time monitoring, fault diagnosis, prognosis, and resilient control and design of wind turbine systems. After a strict peer-review process, 20 papers were selected, which represent the most recent progress of the real-time monitoring, diagnosis, prognosis, and resilient control methods/techniques in wind turbine systems.

  19. Heath Monitoring of Thermal Protection Systems - Preliminary Measurements and Design Specifications

    NASA Technical Reports Server (NTRS)

    Scott, D. A.; Price, D. C.

    2007-01-01

    The work reported here is the first stage of a project that aims to develop a health monitoring system for Thermal Protection Systems (TPS) that enables a vehicle to safely re-enter the Earth's atmosphere. The TPS health monitoring system is to be integrated into an existing acoustic emissions-based Concept Demonstrator, developed by CSIRO, which has been previously demonstrated for evaluating impact damage of aerospace systems.

  20. Generating visual flickers for eliciting robust steady-state visual evoked potentials at flexible frequencies using monitor refresh rate.

    PubMed

    Nakanishi, Masaki; Wang, Yijun; Wang, Yu-Te; Mitsukura, Yasue; Jung, Tzyy-Ping

    2014-01-01

    In the study of steady-state visual evoked potentials (SSVEPs), it remains a challenge to present visual flickers at flexible frequencies using monitor refresh rate. For example, in an SSVEP-based brain-computer interface (BCI), it is difficult to present a large number of visual flickers simultaneously on a monitor. This study aims to explore whether or how a newly proposed frequency approximation approach changes signal characteristics of SSVEPs. At 10 Hz and 12 Hz, the SSVEPs elicited using two refresh rates (75 Hz and 120 Hz) were measured separately to represent the approximation and constant-period approaches. This study compared amplitude, signal-to-noise ratio (SNR), phase, latency, scalp distribution, and frequency detection accuracy of SSVEPs elicited using the two approaches. To further prove the efficacy of the approximation approach, this study implemented an eight-target BCI using frequencies from 8-15 Hz. The SSVEPs elicited by the two approaches were found comparable with regard to all parameters except amplitude and SNR of SSVEPs at 12 Hz. The BCI obtained an averaged information transfer rate (ITR) of 95.0 bits/min across 10 subjects with a maximum ITR of 120 bits/min on two subjects, the highest ITR reported in the SSVEP-based BCIs. This study clearly showed that the frequency approximation approach can elicit robust SSVEPs at flexible frequencies using monitor refresh rate and thereby can largely facilitate various SSVEP-related studies in neural engineering and visual neuroscience.

  1. A pilot crossover study: effects of an intervention using an activity monitor with computerized game functions on physical activity and body composition.

    PubMed

    Nishiwaki, Masato; Kuriyama, Akinori; Ikegami, Yumi; Nakashima, Nana; Matsumoto, Naoyuki

    2014-12-02

    Wearing an activity monitor as a motivational tool and incorporating a behavior-based reward system or a computerized game element might have a synergistic effect on an increase in daily physical activity, thereby inducing body fat reduction. This pilot crossover study aimed to examine the effects of a short-term lifestyle intervention using an activity monitor with computerized game functions on physical activity and body composition. Twenty healthy volunteers (31 ± 3 years) participated in a 12-week crossover study. The participants were randomly assigned to either Group A (a 6-week game intervention followed by a 6-week normal intervention) or Group B (a 6-week normal intervention followed by a 6-week game intervention). The participants wore both a normal activity monitor (Lifecorder EX) and an activity monitor with computerized game functions (Yuuhokei) during the game intervention, whereas they only wore a normal activity monitor during the normal intervention. Before, during, and after the intervention, body composition was assessed. Significantly more daily steps were recorded for the game intervention than for the normal intervention (10,520 ± 562 versus 8,711 ± 523 steps/day, P < 0.01). The participants performed significantly more physical activity at an intensity of ≥ 3 metabolic equivalents (METs) in the game intervention than in the normal intervention (3.1 ± 0.2 versus 2.4 ± 0.2 METs · hour/day, P < 0.01). Although body mass and fat were significantly reduced in both periods (P < 0.01), the difference in body fat reduction was significantly greater in the game intervention than in the normal intervention (P < 0.05). A short-term intervention using an activity monitor with computerized game functions increases physical activity and reduces body fat more effectively than an intervention using a standard activity monitor.

  2. Multicriteria relocation analysis of an off-site radioactive monitoring network for a nuclear power plant.

    PubMed

    Chang, Ni-Bin; Ning, Shu-Kuang; Chen, Jen-Chang

    2006-08-01

    Due to increasing environmental consciousness in most countries, every utility that owns a commercial nuclear power plant has been required to have both an on-site and off-site emergency response plan since the 1980s. A radiation monitoring network, viewed as part of the emergency response plan, can provide information regarding the radiation dosage emitted from a nuclear power plant in a regular operational period and/or abnormal measurements in an emergency event. Such monitoring information might help field operators and decision-makers to provide accurate responses or make decisions to protect the public health and safety. This study aims to conduct an integrated simulation and optimization analysis looking for the relocation strategy of a long-term regular off-site monitoring network at a nuclear power plant. The planning goal is to downsize the current monitoring network but maintain its monitoring capacity as much as possible. The monitoring sensors considered in this study include the thermoluminescence dosimetry (TLD) and air sampling system (AP) simultaneously. It is designed for detecting the radionuclide accumulative concentration, the frequency of violation, and the possible population affected by a long-term impact in the surrounding area regularly while it can also be used in an accidental release event. With the aid of the calibrated Industrial Source Complex-Plume Rise Model Enhancements (ISC-PRIME) simulation model to track down the possible radionuclide diffusion, dispersion, transport, and transformation process in the atmospheric environment, a multiobjective evaluation process can be applied to achieve the screening of monitoring stations for the nuclear power plant located at Hengchun Peninsula, South Taiwan. To account for multiple objectives, this study calculated preference weights to linearly combine objective functions leading to decision-making with exposure assessment in an optimization context. Final suggestions should be useful for narrowing the set of scenarios that decision-makers need to consider in this relocation process.

  3. Automated Instrumentation, Monitoring and Visualization of PVM Programs Using AIMS

    NASA Technical Reports Server (NTRS)

    Mehra, Pankaj; VanVoorst, Brian; Yan, Jerry; Tucker, Deanne (Technical Monitor)

    1994-01-01

    We present views and analysis of the execution of several PVM codes for Computational Fluid Dynamics on a network of Sparcstations, including (a) NAS Parallel benchmarks CG and MG (White, Alund and Sunderam 1993); (b) a multi-partitioning algorithm for NAS Parallel Benchmark SP (Wijngaart 1993); and (c) an overset grid flowsolver (Smith 1993). These views and analysis were obtained using our Automated Instrumentation and Monitoring System (AIMS) version 3.0, a toolkit for debugging the performance of PVM programs. We will describe the architecture, operation and application of AIMS. The AIMS toolkit contains (a) Xinstrument, which can automatically instrument various computational and communication constructs in message-passing parallel programs; (b) Monitor, a library of run-time trace-collection routines; (c) VK (Visual Kernel), an execution-animation tool with source-code clickback; and (d) Tally, a tool for statistical analysis of execution profiles. Currently, Xinstrument can handle C and Fortran77 programs using PVM 3.2.x; Monitor has been implemented and tested on Sun 4 systems running SunOS 4.1.2; and VK uses X11R5 and Motif 1.2. Data and views obtained using AIMS clearly illustrate several characteristic features of executing parallel programs on networked workstations: (a) the impact of long message latencies; (b) the impact of multiprogramming overheads and associated load imbalance; (c) cache and virtual-memory effects; and (4significant skews between workstation clocks. Interestingly, AIMS can compensate for constant skew (zero drift) by calibrating the skew between a parent and its spawned children. In addition, AIMS' skew-compensation algorithm can adjust timestamps in a way that eliminates physically impossible communications (e.g., messages going backwards in time). Our current efforts are directed toward creating new views to explain the observed performance of PVM programs. Some of the features planned for the near future include: (a) ConfigView, showing the physical topology of the virtual machine, inferred using specially formatted IP (Internet Protocol) packets; and (b) LoadView, synchronous animation of PVM-program execution and resource-utilization patterns.

  4. Long-Term Continuous Ambulatory ECG Monitors and External Cardiac Loop Recorders for Cardiac Arrhythmia: A Health Technology Assessment

    PubMed Central

    Kabali, Conrad; Xie, Xuanqian; Higgins, Caroline

    2017-01-01

    Background Ambulatory electrocardiography (ECG) monitors are often used to detect cardiac arrhythmia. For patients with symptoms, an external cardiac loop recorder will often be recommended. The improved recording capacity of newer Holter monitors and similar devices, collectively known as longterm continuous ambulatory ECG monitors, suggests that they will perform just as well as, or better than, external loop recorders. This health technology assessment aimed to evaluate the effectiveness, cost-effectiveness, and budget impact of longterm continuous ECG monitors compared with external loop recorders in detecting symptoms of cardiac arrhythmia. Methods Based on our systematic search for studies published up to January 15, 2016, we did not identify any studies directly comparing the clinical effectiveness of longterm continuous ECG monitors and external loop recorders. Therefore, we conducted an indirect comparison, using a 24-hour Holter monitor as a common comparator. We used a meta-regression model to control for bias due to variation in device-wearing time and baseline syncope rate across studies. We conducted a similar systematic search for cost-utility and cost-effectiveness studies comparing the two types of devices; none were found. Finally, we used historical claims data (2006–2014) to estimate the future 5-year budget impact in Ontario, Canada, of continued public funding for both types of longterm ambulatory ECG monitors. Results Our clinical literature search yielded 7,815 non-duplicate citations, of which 12 cohort studies were eligible for indirect comparison. Seven studies assessed the effectiveness of longterm continuous monitors and five assessed external loop recorders. Both types of devices were more effective than a 24-hour Holter monitor, and we found no substantial difference between them in their ability to detect symptoms (risk difference 0.01; 95% confidence interval −0.18, 0.20). Using GRADE for network meta-analysis, we evaluated the quality of the evidence as low. Our budget impact analysis showed that use of the longterm continuous monitors has grown steadily in Ontario since they became publicly funded in 2006, particularly since 2011 when monitors that can record for 14 days or longer became funded, and the use of external cardiac loop recorders has correspondingly declined. The analysis suggests that, with these trends, continued public funding of both types of longterm ambulatory ECG testing will result in additional costs ranging from $130,000 to $370,000 per year over the next 5 years. Conclusions Although both longterm continuous ambulatory ECG monitors and external cardiac loop recorders were more effective than a 24-hour Holter monitor in detecting symptoms of cardiac arrhythmia, we found no evidence to suggest that these two devices differ in effectiveness. Assuming that the use of longterm continuous monitors will continue to increase in the next 5 years, the public health care system in Ontario can expect to see added costs of $130,000 to $370,000 per year. PMID:28194254

  5. An anaesthesia information management system as a tool for a quality assurance program: 10years of experience.

    PubMed

    Motamed, Cyrus; Bourgain, Jean Louis

    2016-06-01

    Anaesthesia Information Management Systems (AIMS) generate large amounts of data, which might be useful for quality assurance programs. This study was designed to highlight the multiple contributions of our AIMS system in extracting quality indicators over a period of 10years. The study was conducted from 2002 to 2011. Two methods were used to extract anaesthesia indicators: the manual extraction of individual files for monitoring neuromuscular relaxation and structured query language (SQL) extraction for other indicators which were postoperative nausea and vomiting (PONV), pain, sedation scores, pain-related medications, scores and postoperative hypothermia. For each indicator, a program of information/meetings and adaptation/suggestions for operating room and PACU personnel was initiated to improve quality assurance, while data were extracted each year. The study included 77,573 patients. The mean overall completeness of data for the initial years ranged from 55 to 85% and was indicator-dependent, which then improved to 95% completeness for the last 5years. The incidence of neuromuscular monitoring was initially 67% and then increased to 95% (P<0.05). The rate of pharmacological reversal remained around 53% throughout the study. Regarding SQL data, an improvement of severe postoperative pain and PONV scores was observed throughout the study, while mild postoperative hypothermia remained a challenge, despite efforts for improvement. The AIMS system permitted the follow-up of certain indicators through manual sampling and many more via SQL extraction in a sustained and non-time-consuming way across years. However, it requires competent and especially dedicated resources to handle the database. Copyright © 2016 Société française d'anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.

  6. Study protocol for evaluating the implementation and effectiveness of an emergency department longitudinal patient monitoring system using a mixed-methods approach.

    PubMed

    Ward, Marie; McAuliffe, Eilish; Wakai, Abel; Geary, Una; Browne, John; Deasy, Conor; Schull, Michael; Boland, Fiona; McDaid, Fiona; Coughlan, Eoin; O'Sullivan, Ronan

    2017-01-23

    Early detection of patient deterioration is a key element of patient safety as it allows timely clinical intervention and potential rescue, thus reducing the risks of serious patient safety incidents. Longitudinal patient monitoring systems have been widely recommended for use to detect clinical deterioration. However, there is conflicting evidence on whether they improve patient outcomes. This may in part be related to variation in the rigour with which they are implemented and evaluated. This study aims to evaluate the implementation and effectiveness of a longitudinal patient monitoring system designed for adult patients in the unique environment of the Emergency Department (ED). A novel participatory action research (PAR) approach is taken where socio-technical systems (STS) theory and analysis informs the implementation through the improvement methodology of 'Plan Do Study Act' (PDSA) cycles. We hypothesise that conducting an STS analysis of the ED before beginning the PDSA cycles will provide for a much richer understanding of the current situation and possible challenges to implementing the ED-specific longitudinal patient monitoring system. This methodology will enable both a process and an outcome evaluation of implementing the ED-specific longitudinal patient monitoring system. Process evaluations can help distinguish between interventions that have inherent faults and those that are badly executed. Over 1.2 million patients attend EDs annually in Ireland; the successful implementation of an ED-specific longitudinal patient monitoring system has the potential to affect the care of a significant number of such patients. To the best of our knowledge, this is the first study combining PAR, STS and multiple PDSA cycles to evaluate the implementation of an ED-specific longitudinal patient monitoring system and to determine (through process and outcome evaluation) whether this system can significantly improve patient outcomes by early detection and appropriate intervention for patients at risk of clinical deterioration.

  7. An Analysis of the Mother and Child Education Program's Effects on the Relationship between Mothers and Their Five- or Six-Year-Old Children

    ERIC Educational Resources Information Center

    Ulutas, Aysegul; Kanak, Mehmet

    2016-01-01

    This study aims to analyze the effect of the Mother and Child Education Program on the relationship between mothers and their five- or six-year-old children. The study used an experimental design of pretest-posttest-monitoring test with a control group. The participants consisted of 50 preschool children aged five or six along with their mothers.…

  8. An experimental study on the application of radionuclide imaging in repair of the bone defect

    PubMed Central

    Zhu, Weimin; Wang, Daping; Zhang, Xiaojun; Lu, Wei; Liu, Jianquan; Peng, Liangquan; Li, Hao; Han, Yun; Zeng, Yanjun

    2011-01-01

    The aim of our study was to validate the effect of radionuclide imaging in early monitoring of the bone’s reconstruction, the animal model of bone defect was made on the rabbits repaired with HA artificial bone. The ability of bone defect repair was evaluated by using radionuclide bone imaging at 2, 4, 8 and 12 weeks postoperatively. The results indicate that the experimental group stimulated more bone formation than that of the control group. The differences of the bone reconstruction ability were statistically significant (p<0.05). The nano-HA artificial has good bone conduction, and it can be used for the treatment of bone defects. Radionuclide imaging may be an effective and first choice method for the early monitoring of the bone’s reconstruction. PMID:21875418

  9. Orbital Sciences Pegasus XL Flight Simulation

    NASA Image and Video Library

    2007-02-28

    At Vandenberg Air Force Base in California, workers monitor the data produced by the second flight simulation of the Orbital Sciences Pegasus XL rocket. The rocket is the launch vehicle for NASA's Aeronomy of Ice in the Mesosphere, or AIM, spacecraft. AIM is the seventh Small Explorers mission under NASA's Explorer Program. The program provides frequent flight opportunities for world-class scientific investigations from space within heliophysics and astrophysics. The AIM spacecraft will fly three instruments designed to study polar mesospheric clouds located at the edge of space, 50 miles above the Earth's surface in the coldest part of the planet's atmosphere. The mission's primary goal is to explain why these clouds form and what has caused them to become brighter and more numerous and appear at lower latitudes in recent years. AIM's results will provide the basis for the study of long-term variability in the mesospheric climate and its relationship to global climate change. AIM is scheduled to be mated to the Pegasus XL during the second week of April, after which final inspections will be conducted. Launch is scheduled for April 25.

  10. Orbital Sciences Pegasus XL Flight Simulation

    NASA Image and Video Library

    2007-02-28

    At Vandenberg Air Force Base in California, a worker monitors the data produced by the second flight simulation of the Orbital Sciences Pegasus XL rocket. The rocket is the launch vehicle for NASA's Aeronomy of Ice in the Mesosphere, or AIM, spacecraft. AIM is the seventh Small Explorers mission under NASA's Explorer Program. The program provides frequent flight opportunities for world-class scientific investigations from space within heliophysics and astrophysics. The AIM spacecraft will fly three instruments designed to study polar mesospheric clouds located at the edge of space, 50 miles above the Earth's surface in the coldest part of the planet's atmosphere. The mission's primary goal is to explain why these clouds form and what has caused them to become brighter and more numerous and appear at lower latitudes in recent years. AIM's results will provide the basis for the study of long-term variability in the mesospheric climate and its relationship to global climate change. AIM is scheduled to be mated to the Pegasus XL during the second week of April, after which final inspections will be conducted. Launch is scheduled for April 25.

  11. Orbital Sciences Pegasus XL Flight Simulation

    NASA Image and Video Library

    2007-02-28

    At Vandenberg Air Force Base in California, a worker monitors the Orbital Sciences Pegasus XL rocket after a second flight simulation. The rocket is the launch vehicle for NASA's Aeronomy of Ice in the Mesosphere, or AIM, spacecraft. AIM is the seventh Small Explorers mission under NASA's Explorer Program. The program provides frequent flight opportunities for world-class scientific investigations from space within heliophysics and astrophysics. The AIM spacecraft will fly three instruments designed to study polar mesospheric clouds located at the edge of space, 50 miles above the Earth's surface in the coldest part of the planet's atmosphere. The mission's primary goal is to explain why these clouds form and what has caused them to become brighter and more numerous and appear at lower latitudes in recent years. AIM's results will provide the basis for the study of long-term variability in the mesospheric climate and its relationship to global climate change. AIM is scheduled to be mated to the Pegasus XL during the second week of April, after which final inspections will be conducted. Launch is scheduled for April 25.

  12. On the use of multi-agent systems for the monitoring of industrial systems

    NASA Astrophysics Data System (ADS)

    Rezki, Nafissa; Kazar, Okba; Mouss, Leila Hayet; Kahloul, Laid; Rezki, Djamil

    2016-03-01

    The objective of the current paper is to present an intelligent system for complex process monitoring, based on artificial intelligence technologies. This system aims to realize with success all the complex process monitoring tasks that are: detection, diagnosis, identification and reconfiguration. For this purpose, the development of a multi-agent system that combines multiple intelligences such as: multivariate control charts, neural networks, Bayesian networks and expert systems has became a necessity. The proposed system is evaluated in the monitoring of the complex process Tennessee Eastman process.

  13. “I Was Relieved to Know That My Baby Was Safe”: Women’s Attitudes and Perceptions on Using a New Electronic Fetal Heart Rate Monitor during Labor in Tanzania

    PubMed Central

    Rivenes Lafontan, Sara; Sundby, Johanne; Ersdal, Hege L.; Abeid, Muzdalifat; Kidanto, Hussein L.; Mbekenga, Columba K.

    2018-01-01

    To increase labor monitoring and prevent neonatal morbidity and mortality, a new wireless, strap-on electronic fetal heart rate monitor called Moyo was introduced in Tanzania in 2016. As part of the ongoing evaluation of the introduction of the monitor, the aim of this study was to explore the attitudes and perceptions of women who had worn the monitor continuously during their most recent delivery and perceptions about how it affected care. This knowledge is important to identify barriers towards adaptation in order to introduce new technology more effectively. We carried out 20 semi-structured individual interviews post-labor at two hospitals in Tanzania. A thematic content analysis was used to analyze the data. Our results indicated that the use of the monitor positively affected the women’s birth experience. It provided much-needed reassurance about the wellbeing of the child. The women considered that wearing Moyo improved care due to an increase in communication and attention from birth attendants. However, the women did not fully understand the purpose and function of the device and overestimated its capabilities. This highlights the need to improve how and when information is conveyed to women in labor. PMID:29425167

  14. INFORMAS (International Network for Food and Obesity/non-communicable diseases Research, Monitoring and Action Support): summary and future directions.

    PubMed

    Kumanyika, S

    2013-10-01

    This supplement presents the foundational elements for INFORMAS (International Network for Food and Obesity/non-communicable diseases Research, Monitoring and Action Support). As explained in the overview article by Swinburn and colleagues, INFORMAS has a compelling rationale and has set forth clear objectives, outcomes, principles and frameworks for monitoring and benchmarking key aspects of food environments and the policies and actions that influence the healthiness of food environments. This summary highlights the proposed monitoring approaches for the 10 interrelated INFORMAS modules: public and private sector policies and actions; key aspects of food environments (food composition, labelling, promotion, provision, retail, prices, and trade and investment) and population outcomes (diet quality). This ambitious effort should be feasible when approached in a step-wise manner, taking into account existing monitoring efforts, data sources, country contexts and capacity, and when adequately resourced. After protocol development and pilot testing of the modules, INFORMAS aims to be a sustainable, low-cost monitoring framework. Future directions relate to institutionalization, implementation and, ultimately, to leveraging INFORMAS data in ways that will bring key drivers of food environments into alignment with public health goals. © 2013 The Authors. Obesity Reviews published by John Wiley & Sons Ltd on behalf of the International Association for the Study of Obesity.

  15. 4onse: four times open & non-conventional technology for sensing the environment

    NASA Astrophysics Data System (ADS)

    Cannata, Massimiliano; Ratnayake, Rangageewa; Antonovic, Milan; Strigaro, Daniele; Cardoso, Mirko; Hoffmann, Marcus

    2017-04-01

    The availability of complete, quality and dense monitoring hydro-meteorological data is essential to address a number of practical issues including, but not limited to, flood-water and urban drainage management, climate change impact assessment, early warning and risk management, now-casting and weather predictions. Thanks to the recent technological advances such as Internet Of Things, Big Data and Ubiquitous Internet, non-conventional monitoring systems based on open technologies and low cost sensors may represent a great opportunity either as a complement of authoritative monitoring network or as a vital source of information wherever existing monitoring networks are in decline or completely missing. Nevertheless, scientific literature on such a kind of open and non-conventional monitoring systems is still limited and often relates to prototype engineering and testing in rather limited case studies. For this reason the 4onse project aims at integrating existing open technologies in the field of Free & Open Source Software, Open Hardware, Open Data, and Open Standards and evaluate this kind of system in a real case (about 30 stations) for a medium period of 2 years to better scientifically understand strengths, criticalities and applicabilities in terms of data quality; system durability; management costs; performances; sustainability. The ultimate objective is to contribute in non-conventional monitoring systems adoption based on four open technologies.

  16. [Implementation of a post-discharge surgical site infection system in herniorrhaphy and mastectomy procedures].

    PubMed

    San Juan Sanz, Isabel; Díaz-Agero-Pérez, Cristina; Robustillo-Rodela, Ana; Pita López, María José; Oliva Iñiguez, Lourdes; Monge-Jodrá, Vicente

    2014-10-01

    Monitoring surgical site infection (SSI) performed during hospitalization can underestimate its rates due to the shortening in hospital stay. The aim of this study was to determine the actual rates of SSI using a post-discharge monitoring system. All patients who underwent herniorraphy or mastectomy in the Hospital Universitario Ramón y Cajal from 1 January 2011 to 31 December 2011 were included. SSI data were collected prospectively according to the continuous quality improvement indicators (Indicadores Clinicos de Mejora Continua de la Calidad [INCLIMECC]) monitoring system. Post-discharge follow-up was conducted by telephone survey. A total of 409patients were included in the study, of whom 299 underwent a herniorraphy procedure, and 110 underwent a mastectomy procedure. For herniorrhaphy, the SSI rate increased from 6.02% to 7.6% (the post-discharge survey detected 21.7% of SSI). For mastectomy, the SSI rate increased from 1.8% to 3.6% (the post-discharge survey detected 50% of SSI). Post-discharge monitoring showed an increased detection of SSI incidence. Post-discharge monitoring is useful to analyze the real trend of SSI, and evaluate improvement actions. Post-discharge follow-up methods need to standardised. Copyright © 2013 Elsevier España, S.L.U. y Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  17. Features and application of wearable biosensors in medical care

    PubMed Central

    Ajami, Sima; Teimouri, Fotooheh

    2015-01-01

    One of the new technologies in the field of health is wearable biosensor, which provides vital signs monitoring of patients, athletes, premature infants, children, psychiatric patients, people who need long-term care, elderly, and people in impassable regions far from health and medical services. The aim of this study was to explain features and applications of wearable biosensors in medical services. This was a narrative review study that done in 2015. Search conducted with the help of libraries, books, conference proceedings, through databases of Science Direct, PubMed, Proquest, Springer, and SID (Scientific Information Database). In our searches, we employed the following keywords and their combinations; vital sign monitoring, medical smart shirt, smart clothing, wearable biosensors, physiological monitoring system, remote detection systems, remote control health, and bio-monitoring system. The preliminary search resulted in 54 articles, which published between 2002 and 2015. After a careful analysis of the content of each paper, 41 sources selected based on their relevancy. Although the use of wearable in healthcare is still in an infant stage, it could have a magic effect on healthcare. Smart wearable in the technology industry for 2015 is one that is looking to be a big and profitable market. Wearable biosensors capable of continuous vital signs monitoring and feedback to the user will be significantly effective in timely prevention, diagnosis, treatment, and control of diseases. PMID:26958058

  18. Finding the Key Periods for Assimilating HJ-1A/B CCD Data and the WOFOST Model to Evaluate Heavy Metal Stress in Rice.

    PubMed

    Zhao, Shuang; Qian, Xu; Liu, Xiangnan; Xu, Zhao

    2018-04-17

    Accurately monitoring heavy metal stress in crops is vital for food security and agricultural production. The assimilation of remote sensing images into the World Food Studies (WOFOST) model provides an efficient way to solve this problem. In this study, we aimed at investigating the key periods of the assimilation framework for continuous monitoring of heavy metal stress in rice. The Harris algorithm was used for the leaf area index (LAI) curves to select the key period for an optimized assimilation. To obtain accurate LAI values, the measured dry weight of rice roots (WRT), which have been proven to be the most stress-sensitive indicator of heavy metal stress, were incorporated into the improved WOFOST model. Finally, the key periods, which contain four dominant time points, were used to select remote sensing images for the RS-WOFOST model for continuous monitoring of heavy metal stress. Compared with the key period which contains all the available remote sensing images, the results showed that the optimal key period can significantly improve the time efficiency of the assimilation framework by shortening the model operation time by more than 50%, while maintaining its accuracy. This result is highly significant when monitoring heavy metals in rice on a large-scale. Furthermore, it can also offer a reference for the timing of field measurements in monitoring heavy metal stress in rice.

  19. Yield of prolonged wireless pH monitoring in achalasia patients successfully treated with pneumatic dilation

    PubMed Central

    Franchina, Marianna; Elvevi, Alessandra; Pugliese, Delia; Tenca, Andrea; Conte, Dario; Penagini, Roberto

    2016-01-01

    Background Gastro-oesophageal reflux disease (GORD) is a long-term complication of achalasia treatments. The aim of our study was to evaluate the yield of prolonged wireless pH monitoring in patients with successfully treated achalasia and its influence on proton pump inhibitor (PPI) use. Methods Twenty-five patients with achalasia who underwent prolonged wireless pH monitoring after a successful treatment with pneumatic dilation were enrolled. pH variables were analysed in the first 24 hours of monitoring to determine if tracings were indicative of GORD; the same variables were analysed in the following 24-hour period in order to obtain a worst-day diagnosis of GORD. PPI therapy before and after the test was recorded. Results Five out of 25 patients had GORD diagnosis during the first day of monitoring and four of them had oesophagitis at endoscopy. During the following days of monitoring four more patients had a diagnosis of GORD. Out of the 25 patients, PPIs were started after the test in six asymptomatic GORD-positive ones, whereas prescription of PPIs was stopped without detrimental effect on symptoms in three GORD-negative patients. Conclusions Prolonged wireless pH monitoring is a useful test to be added to endoscopy in order to evaluate GORD and to optimise antisecretory treatment in successfully treated achalasia patients. PMID:29026592

  20. Scaled Inverse Probability Weighting: A Method to Assess Potential Bias Due to Event Nonreporting in Ecological Momentary Assessment Studies

    ERIC Educational Resources Information Center

    Kovalchik, Stephanie A.; Martino, Steven C.; Collins, Rebecca L.; Shadel, William G.; D'Amico, Elizabeth J.; Becker, Kirsten

    2018-01-01

    Ecological momentary assessment (EMA) is a popular assessment method in psychology that aims to capture events, emotions, and cognitions in real time, usually repeatedly throughout the day. Because EMA typically involves more intensive monitoring than traditional assessment methods, missing data are commonly an issue and this missingness may bias…

  1. Peer Interaction and Corrective Feedback for Accuracy and Fluency Development: Monitoring, Practice, and Proceduralization

    ERIC Educational Resources Information Center

    Sato, Masatoshi; Lyster, Roy

    2012-01-01

    This quasi-experimental study is aimed at (a) teaching learners how to provide corrective feedback (CF) during peer interaction and (b) assessing the effects of peer interaction and CF on second language (L2) development. Four university-level English classes in Japan participated (N = 167), each assigned to one of four treatment conditions. Of…

  2. Access to What? Creating a Composite Measure of Educational Quantity and Educational Quality for 11 African Countries

    ERIC Educational Resources Information Center

    Spaull, Nicholas; Taylor, Stephen

    2015-01-01

    The aim of the current study is to create a composite statistic of educational quantity and educational quality by combining household data (Demographic and Health Survey) on grade completion and survey data (Southern and Eastern African Consortium for Monitoring Educational Quality) on cognitive outcomes for 11 African countries: Kenya, Lesotho,…

  3. Assessment of Metacognitive Knowledge among Science Students, a Case Study of Two Bilingual and Two NNS Students

    ERIC Educational Resources Information Center

    Ali, Gadacha

    2007-01-01

    This investigation aims to assess awareness of genre and writing skills among science students via an abstract writing task, with recall and follow-up protocols to monitor the students, and to characterize the relationship between the abstract and the base article. Abstract writing involves specific data selection techniques of activities involved…

  4. Assessment of Job Satisfaction among Faculty Members and Its Relationship with Some Variables in Najran University

    ERIC Educational Resources Information Center

    Al-Smadi, Marwan Saleh; Qblan, Yahya Mohammed

    2015-01-01

    It is vital that colleges and universities monitor the satisfaction levels of their employees to secure high levels of their performance. The current study aimed to identify the impact of some variables (gender, Teaching experience and college type) on assessing the level of job satisfaction among faculty of Najran University. A survey was…

  5. Early Markers of Language Delay in Children with and without Family Risk for Dyslexia

    ERIC Educational Resources Information Center

    Unhjem, Astrid; Eklund, Kenneth; Nergård-Nilssen, Trude

    2015-01-01

    This study examined the extent to which receptive and productive vocabulary between ages 12 and 18 months predicted language skills at age 24 months in children born with family risk for dyslexia (FR) and a control group born without that risk. The aim was to identify possible markers of early language delay. The authors monitored vocabulary…

  6. Forest fires and air quality issues in southern Europe

    Treesearch

    Ana Isabel Miranda; Enrico Marchi; Marco Ferretti; Millán M. Millán

    2009-01-01

    Each summer forest fires in southern Europe emit large quantities of pollutants to the atmosphere. These fires can generate a number of air pollution episodes as measured by air quality monitoring networks. We analyzed the impact of forest fires on air quality of specific regions of southern Europe. Data from several summer seasons were studied with the aim of...

  7. Recall of a Live and Personally Experienced Eyewitness Event by Adults with Autism Spectrum Disorder

    ERIC Educational Resources Information Center

    Maras, Katie L.; Memon, Amina; Lambrechts, Anna; Bowler, Dermot M.

    2013-01-01

    The aim of the present study was to (a) extend previous eyewitness research in autism spectrum disorder (ASD) using a live and personally experienced event; (b) examine whether witnesses with ASD demonstrate a facilitative effect in memory for self- over other-performed actions; (c) explore source monitoring abilities by witnesses with ASD in…

  8. Parenting Behaviors, Association with Deviant Peers, and Delinquency in African American Adolescents: A Mediated-Moderation Model

    ERIC Educational Resources Information Center

    Bowman, Marvella A.; Prelow, Hazel M.; Weaver, Scott R.

    2007-01-01

    The aim of the present study was to examine a model positing that association with deviant peers mediates the relation between adolescent perceived parenting behaviors (maternal monitoring and involvement), the interaction of these parenting behaviors, and delinquency in a sample of 135 urban African American adolescents (13-19 years of age).…

  9. Asessment of adequacy of the monitoring method in the activity of a verification laboratory

    NASA Astrophysics Data System (ADS)

    Ivanov, R. N.; Grinevich, V. A.; Popov, A. A.; Shalay, V. V.; Malaja, L. D.

    2018-04-01

    Questions of assessing adequacy of a risk monitoring technique for a verification laboratory operation concerning the conformity to the accreditation criteria, and aimed at decision-making on advisability of a verification laboratory activities in the declared area of accreditation are considered.

  10. Environmental Monitoring Curriculum System and Application-Oriented Training

    ERIC Educational Resources Information Center

    Wang, Jing-Ping; Wang, Xin-Hong

    2016-01-01

    Through building the environmental monitoring curriculum system for application-oriented talents, the comprehensive design and practice were constructed from the syllabus, textbooks, web-based courses, top-quality courses, test paper bank, open laboratory and scientific research etc. The aims are to promote environmental science professional,…

  11. Trigger Menu-aware Monitoring for the ATLAS experiment

    NASA Astrophysics Data System (ADS)

    Hoad, Xanthe; ATLAS Collaboration

    2017-10-01

    We present a“trigger menu-aware” monitoring system designed for the Run-2 data-taking of the ATLAS experiment at the LHC. Unlike Run-1, where a change in the trigger menu had to be matched by the installation of a new software release at Tier-0, the new monitoring system aims to simplify the ATLAS operational workflows. This is achieved by integrating monitoring updates in a quick and flexible manner via an Oracle DB interface. We present the design and the implementation of the menu-aware monitoring, along with lessons from the operational experience of the new system with the 2016 collision data.

  12. Salivary alpha amylase in on-call from home fire and emergency service personnel.

    PubMed

    Hall, Sarah J; Aisbett, Brad; Robertson, Samuel J; Ferguson, Sally A; Turner, Anne I

    2017-11-01

    The effect of working on-call from home on the sympatho-adrenal medullary system activity is currently unknown. This study had two aims, Aim 1: examine salivary alpha amylase awakening response (AAR) and diurnal salivary alpha amylase (sAA) profile in fire and emergency service workers who operate on-call from home following a night on-call with a call (NIGHT-CALL), a night on-call without a call (NO-CALL) and an off-call night (OFF-CALL), and Aim 2: explore whether there was an anticipatory effect of working on-call from home (ON) compared to when there was an off-call (OFF) on the diurnal sAA profile. Participants wore activity monitors, completed sleep and work diaries and collected seven saliva samples a day for one week. AAR area under the curve with respect to ground (AUC G ), AAR area under the curve with respect to increase (AUC I ), AAR reactivity, diurnal sAA slope, diurnal sAA AUC G and mean 12-h sAA concentrations were calculated. Separate generalised estimating equation models were constructed for each variable of interest for each aim. For Aim 1, there were no differences between NIGHT-CALL or NO-CALL and OFF-CALL for any response variable. For Aim 2, there was no difference between any response variable of interest when ON the following night compared to when OFF the following night ( n  = 14). These findings suggest that there is no effect of working on-call from home on sAA, but should be interpreted with caution, as overnight data were not collected. Future research, using overnight heart rate monitoring, could help confirm these findings. © 2017 The authors.

  13. Screening for asymptomatic atrial fibrillation while monitoring the blood pressure at home: trial of regular versus irregular pulse for prevention of stroke (TRIPPS 2.0).

    PubMed

    Wiesel, Joseph; Abraham, Saji; Messineo, Frank C

    2013-06-01

    Asymptomatic atrial fibrillation (AF) is a common cause of strokes. Physician screening for AF has been recommended. Home screening for AF may increase the likelihood of detecting asymptomatic AF in patients at risk for stroke because of AF. The aim of this study was to assess the feasibility and accuracy of screening for AF when taking home blood pressure (BP) measurements using an automatic AF-detecting BP monitor. Subjects aged >64 years or those with hypertension, diabetes, congestive heart failure, or previous stroke were enrolled by their primary physicians and given the AF-BP monitor and an electrocardiographic event monitor to use at home for 30 days. The AF-BP monitor reading was compared with the electrocardiographic reading to calculate the sensitivity and specificity of the device for detecting AF. A total of 160 subjects were enrolled, with 10 withdrawing, 1 excluded, and 10 with no AF-BP monitor logs or electrocardiographic recordings. Of the 139 subjects included, 14 had known AF. There was a total of 3,316 days with AF-BP monitor readings and electrocardiographic readings. On the basis of the initial daily AF-BP monitor readings, the AF-BP monitor demonstrated sensitivity of 99.2% and specificity of 92.9% for detecting AF. Two subjects with no histories of AF had AF-BP monitor readings of AF that were confirmed by the electrocardiographic monitor. One of these subjects was started on warfarin. In conclusion, home screening for asymptomatic AF while taking BP measurements can be performed accurately. This can be used to detect new AF, allowing treatment with anticoagulation to reduce the future risk for stroke. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. Total Arsenic, Cadmium, and Lead Determination in Brazilian Rice Samples Using ICP-MS

    PubMed Central

    Buzzo, Márcia Liane; de Arauz, Luciana Juncioni; Carvalho, Maria de Fátima Henriques; Arakaki, Edna Emy Kumagai; Matsuzaki, Richard; Tiglea, Paulo

    2016-01-01

    This study is aimed at investigating a suitable method for rice sample preparation as well as validating and applying the method for monitoring the concentration of total arsenic, cadmium, and lead in rice by using Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Various rice sample preparation procedures were evaluated. The analytical method was validated by measuring several parameters including limit of detection (LOD), limit of quantification (LOQ), linearity, relative bias, and repeatability. Regarding the sample preparation, recoveries of spiked samples were within the acceptable range from 89.3 to 98.2% for muffle furnace, 94.2 to 103.3% for heating block, 81.0 to 115.0% for hot plate, and 92.8 to 108.2% for microwave. Validation parameters showed that the method fits for its purpose, being the total arsenic, cadmium, and lead within the Brazilian Legislation limits. The method was applied for analyzing 37 rice samples (including polished, brown, and parboiled), consumed by the Brazilian population. The total arsenic, cadmium, and lead contents were lower than the established legislative values, except for total arsenic in one brown rice sample. This study indicated the need to establish monitoring programs for emphasizing the study on this type of cereal, aiming at promoting the Public Health. PMID:27766178

  15. "It's Like a Cyber-Security Blanket": The Utility of Remote Activity Monitoring in Family Dementia Care.

    PubMed

    Mitchell, Lauren L; Peterson, Colleen M; Rud, Shaina R; Jutkowitz, Eric; Sarkinen, Andrielle; Trost, Sierra; Porta, Carolyn M; Finlay, Jessica M; Gaugler, Joseph E

    2018-03-01

    Technologies have emerged that aim to help older persons with Alzheimer's disease and related dementias (ADRDs) remain at home while also supporting their caregiving family members. However, the usefulness of these innovations, particularly in home-based care contexts, remains underexplored. The current study evaluated the acceptability and utility of an in-home remote activity monitoring (RAM) system for 30 family caregivers of persons with ADRD via quantitative survey data collected over a 6-month period and qualitative survey and interview data collected for up to 18 months. A parallel convergent mixed methods design was employed. The integrated qualitative and quantitative data suggested that RAM technology offered ongoing monitoring and provided caregivers with a sense of security. Considerable customization was needed so that RAM was most appropriate for persons with ADRD. The findings have important clinical implications when considering how RAM can supplement, or potentially substitute for, ADRD family care.

  16. Wireless Sensor Networks for Oceanographic Monitoring: A Systematic Review

    PubMed Central

    Albaladejo, Cristina; Sánchez, Pedro; Iborra, Andrés; Soto, Fulgencio; López, Juan A.; Torres, Roque

    2010-01-01

    Monitoring of the marine environment has come to be a field of scientific interest in the last ten years. The instruments used in this work have ranged from small-scale sensor networks to complex observation systems. Among small-scale networks, Wireless Sensor Networks (WSNs) are a highly attractive solution in that they are easy to deploy, operate and dismantle and are relatively inexpensive. The aim of this paper is to identify, appraise, select and synthesize all high quality research evidence relevant to the use of WSNs in oceanographic monitoring. The literature is systematically reviewed to offer an overview of the present state of this field of study and identify the principal resources that have been used to implement networks of this kind. Finally, this article details the challenges and difficulties that have to be overcome if these networks are to be successfully deployed. PMID:22163583

  17. Automatic diet monitoring: a review of computer vision and wearable sensor-based methods.

    PubMed

    Hassannejad, Hamid; Matrella, Guido; Ciampolini, Paolo; De Munari, Ilaria; Mordonini, Monica; Cagnoni, Stefano

    2017-09-01

    Food intake and eating habits have a significant impact on people's health. Widespread diseases, such as diabetes and obesity, are directly related to eating habits. Therefore, monitoring diet can be a substantial base for developing methods and services to promote healthy lifestyle and improve personal and national health economy. Studies have demonstrated that manual reporting of food intake is inaccurate and often impractical. Thus, several methods have been proposed to automate the process. This article reviews the most relevant and recent researches on automatic diet monitoring, discussing their strengths and weaknesses. In particular, the article reviews two approaches to this problem, accounting for most of the work in the area. The first approach is based on image analysis and aims at extracting information about food content automatically from food images. The second one relies on wearable sensors and has the detection of eating behaviours as its main goal.

  18. Hemodynamic monitoring of middle cerebral arteries during cognitive tasks performance.

    PubMed

    Boban, Marina; Črnac, Petra; Junaković, Anamari; Malojčić, Branko

    2014-11-01

    The aim of this study was to obtain temporal pattern and hemispheric dominance of blood flow velocity (BFV) changes and to assess suitability of different cognitive tasks for monitoring of BFV changes in the middle cerebral arteries (MCA). BFV were recorded simultaneously in MCA during performance of phonemic verbal fluency test (pVFT), Trail Making Tests A and B (TMTA and TMTB) and Stroop tests in 14 healthy, right-handed volunteers aged 20-26 years. A significant increase of BFV in both MCA was obtained during performance of all cognitive tasks. Statistically significant lateralization was found during performance of Stroop test with incongruent stimuli, while TMTB was found to have the best activation potential for MCA. Our findings specify TMTB as the most suitable cognitive test for monitoring of BFV in MCA. © 2014 The Authors. Psychiatry and Clinical Neurosciences © 2014 Japanese Society of Psychiatry and Neurology.

  19. Community-Based ECG Monitoring System for Patients with Cardiovascular Diseases.

    PubMed

    Lin, Bor-Shyh; Wong, Alice M; Tseng, Kevin C

    2016-04-01

    This study aims to develop a community-based electrocardiogram (ECG) monitoring system for cardiac outpatients to wirelessly detect heart rate, provide personalized healthcare, and enhance interactive social contact because of the prevalence of deaths from cardiovascular disease and the growing problem of aging in the world. The system not only strengthens the performance of the ECG monitoring system but also emphasizes the ergonomic design of wearable devices and user interfaces. In addition, it enables medical professionals to diagnose cardiac symptoms remotely and electronically manage medical reports and suggestions. The experimental result shows high performance of the dry electrode, even in dynamic conditions. The comparison result with different ECG healthcare systems shows the essential factors that the system should possess and the capability of the proposed system. Finally, a user survey was conducted based on the unified theory of acceptance and users of technology (UTAUT) model.

  20. Impaired cerebral autoregulation and brain injury in newborns with hypoxic-ischemic encephalopathy treated with hypothermia.

    PubMed

    Massaro, An N; Govindan, R B; Vezina, Gilbert; Chang, Taeun; Andescavage, Nickie N; Wang, Yunfei; Al-Shargabi, Tareq; Metzler, Marina; Harris, Kari; du Plessis, Adre J

    2015-08-01

    Impaired cerebral autoregulation may contribute to secondary injury in newborns with hypoxic-ischemic encephalopathy (HIE). Continuous, noninvasive assessment of cerebral pressure autoregulation can be achieved with bedside near-infrared spectroscopy (NIRS) and systemic mean arterial blood pressure (MAP) monitoring. This study aimed to evaluate whether impaired cerebral autoregulation measured by NIRS-MAP monitoring during therapeutic hypothermia and rewarming relates to outcome in 36 newborns with HIE. Spectral coherence analysis between NIRS and MAP was used to quantify changes in the duration [pressure passivity index (PPI)] and magnitude (gain) of cerebral autoregulatory impairment. Higher PPI in both cerebral hemispheres and gain in the right hemisphere were associated with neonatal adverse outcomes [death or detectable brain injury by magnetic resonance imaging (MRI), P < 0.001]. NIRS-MAP monitoring of cerebral autoregulation can provide an ongoing physiological biomarker that may help direct care in perinatal brain injury. Copyright © 2015 the American Physiological Society.

  1. Capacitive Sensing for Non-Invasive Breathing and Heart Monitoring in Non-Restrained, Non-Sedated Laboratory Mice.

    PubMed

    González-Sánchez, Carlos; Fraile, Juan-Carlos; Pérez-Turiel, Javier; Damm, Ellen; Schneider, Jochen G; Zimmermann, Heiko; Schmitt, Daniel; Ihmig, Frank R

    2016-07-07

    Animal testing plays a vital role in biomedical research. Stress reduction is important for improving research results and increasing the welfare and the quality of life of laboratory animals. To estimate stress we believe it is of great importance to develop non-invasive techniques for monitoring physiological signals during the transport of laboratory animals, thereby allowing the gathering of information on the transport conditions, and, eventually, the improvement of these conditions. Here, we study the suitability of commercially available electric potential integrated circuit (EPIC) sensors, using both contact and contactless techniques, for monitoring the heart rate and breathing rate of non-restrained, non-sedated laboratory mice. The design has been tested under different scenarios with the aim of checking the plausibility of performing contactless capture of mouse heart activity (ideally with an electrocardiogram). First experimental results are shown.

  2. Carers' perceptions of the impact of home telehealth monitoring on the provision of care and sustainability of use.

    PubMed

    Wade, Rachael; Cartwright, Colleen; Shaw, Kelly

    2015-06-01

    This paper aims to report carers' perceptions of the impact of home telehealth on the provision of care and the sustainability of home telehealth use. This paper is reporting on a sample of 15 carers who were involved in the telehealth arm of a larger controlled trial. Carers primarily believed that telehealth helped to provide better care. None of the carers had organised, or planned to organise, ongoing telehealth monitoring beyond the study. The main reason given for non-sustained usage was the belief that the person they cared for no longer required, or would benefit from, the monitoring. As the person being cared for was a frail older person with multiple chronic diseases and a history of recent hospitalisation, the non-sustained usage of home telehealth by carers raises questions about what is needed to ensure sustainability of use; this requires further investigation. © 2014 AJA Inc.

  3. Ambient air quality programmes for health impact assessment in the WHO European region.

    PubMed

    Mücke, H G

    2000-06-01

    An important aim of air quality assessment is to provide information about population exposure and health impact assessment. Numerous epidemiological studies have already shown that exposure to excessive levels of ambient air pollutants are associated with either acute or chronic health effects. Until recently, the adequacy of monitoring population exposure in relation to quantitative assessment of health effects of air pollution was rarely considered in ambient air monitoring strategies. This made the formulation of health-related recommendations to risk management difficult and weakens preventive and other measures to reduce adverse health effects of air pollution. To improve local and national capacities for health impact assessment, the European Centre for Environment and Health of the World Health Organization has prepared methodology guidelines concerning selected aspects of air monitoring. The WHO Collaborating Centre for Air Quality Management and Air Pollution Control support efforts in line with international programmes on quality assurance and control for Europe.

  4. Note: Real time optical sensing of alpha-radiation emitting radioactive aerosols based on solid state nuclear track detector.

    PubMed

    Kulkarni, A; Ha, S; Joshirao, P; Manchanda, V; Bak, M S; Kim, T

    2015-06-01

    A sensitive radioactive aerosols sensor has been designed and developed. Its design guidance is based on the need for a low operational cost and reliable measurements to provide daily aerosol monitoring. The exposure of diethylene-glycol bis (allylcarbonate) to radiation causes modification of its physico-chemical properties like surface roughness and reflectance. In the present study, optical sensor based on the reflectance measurement has been developed with an aim to monitor real time presence of alpha radioactive aerosols emitted from thorium nitrate hydrate. The results shows that the fabricated sensor can detect 0.0157 kBq to 0.1572 kBq of radio activity by radioactive aerosols generated from (Th(NO3)4 ⋅ 5H2O) at 0.1 ml/min flow rate. The proposed instrument will be helpful to monitor radioactive aerosols in/around a nuclear facility, building construction sites, mines, and granite polishing factories.

  5. MRI in the assessment and monitoring of multiple sclerosis: an update on best practice

    PubMed Central

    Kaunzner, Ulrike W.; Gauthier, Susan A.

    2017-01-01

    Magnetic resonance imaging (MRI) has developed into the most important tool for the diagnosis and monitoring of multiple sclerosis (MS). Its high sensitivity for the evaluation of inflammatory and neurodegenerative processes in the brain and spinal cord has made it the most commonly used technique for the evaluation of patients with MS. Moreover, MRI has become a powerful tool for treatment monitoring, safety assessment as well as for the prognostication of disease progression. Clinically, the use of MRI has increased in the past couple decades as a result of improved technology and increased availability that now extends well beyond academic centers. Consequently, there are numerous studies supporting the role of MRI in the management of patients with MS. The aim of this review is to summarize the latest insights into the utility of MRI in MS. PMID:28607577

  6. Adolescent-Parent Attachment and Externalizing Behavior: The Mediating Role of Individual and Social Factors.

    PubMed

    de Vries, Sanne L A; Hoeve, Machteld; Stams, Geert Jan J M; Asscher, Jessica J

    2016-02-01

    The aim of this study was to test whether the associations between adolescent-parent attachment and externalizing problem behavior of adolescents were mediated by adolescent cognitive distortions, self-esteem, parental monitoring and association with deviant peers. A total of 102 adolescents (71 % male; aged 12-19 years) at risk for developing delinquent behaviors reported on attachment, parental monitoring, aggressive and delinquent behavior and peers. Mediation effects were tested by using structural equation modeling. Different pathways were found depending on the type of externalizing behavior. The association between attachment and direct and indirect aggressive behavior was mediated by cognitive distortions. The relation between attachment and delinquency was mediated by deviant peers and parental monitoring. We argue that clinical practice should focus on the attachment relationship between adolescent and parents in order to positively affect risk and protective factors for adolescents' aggressive and delinquent behavior.

  7. Utility of video-EEG monitoring in a tertiary care epilepsy center.

    PubMed

    Kumar-Pelayo, M; Oller-Cramsie, M; Mihu, N; Harden, C

    2013-09-01

    Our video-EEG monitoring (VEEG) unit is part of a typical metropolitan tertiary care center that services a diverse patient population. We aimed to determine if the specific clinical reason for inpatient VEEG was actually resolved. Our method was to retrospectively determine the stated goal of inpatient VEEG and to analyze the outcome of one hundred consecutive adult patients admitted for VEEG. The reason for admission fit into one of four categories: 1) to characterize paroxysmal events as either epileptic or nonepileptic, 2) to localize epileptic foci, 3) to characterize the epilepsy syndrome, and 4) to attempt safe antiepileptic drug adjustment. We found that VEEG was successful in accomplishing the goal of admission in 77% of cases. The remaining 23% failed primarily due to lack of typical events during monitoring. Furthermore, of the overall study cohort, VEEG outcomes altered medical management in 53% and surgery was pursued in 5%. © 2013.

  8. Small scale monitoring of a bioremediation barrier using miniature electrical resistivity tomography

    NASA Astrophysics Data System (ADS)

    Sentenac, Philippe; Hogson, Tom; Keenan, Helen; Kulessa, Bernd

    2015-04-01

    The aim of this study was to assess, in the laboratory, the efficiency of a barrier of oxygen release compound (ORC) to block and divert a diesel plume migration in a scaled aquifer model using miniature electrical resistivity tomography (ERT) as the monitoring system. Two plumes of contaminant (diesel) were injected in a soil model made of local sand and clay. The diesel plumes migration was imaged and monitored using a miniature resistivity array system that has proved to be accurate in soil resistivity variations in small-scaled models of soil. ERT results reflected the lateral spreading and diversion of the diesel plumes in the unsaturated zone. One of the contaminant plumes was partially blocked by the ORC barrier and a diversion and reorganisation of the diesel in the soil matrix was observed. The technique of time-lapse ERT imaging showed that a dense non-aqueous phase liquid (DNAPL) contaminant like diesel can be monitored through a bioremediation barrier and the technique is well suited to monitor the efficiency of the barrier. Therefore, miniature ERT as a small-scale modelling tool could complement conventional techniques, which require more expensive and intrusive site investigation prior to remediation.

  9. Monitoring and root cause analysis of clinical biochemistry turn around time at an academic hospital.

    PubMed

    Chauhan, Kiran P; Trivedi, Amit P; Patel, Dharmik; Gami, Bhakti; Haridas, N

    2014-10-01

    Quality can be defined as the ability of a product or service to satisfy the needs and expectations of the customer. Laboratories are more focusing on technical and analytical quality for reliability and accuracy of test results. Patients and clinicians however are interested in rapid, reliable and efficient service from laboratory. Turn around time (TAT), the timeliness with which laboratory personnel deliver test results, is one of the most noticeable signs of laboratory service and is often used as a key performance indicator of laboratory performance. This study is aims to provide clue for laboratory TAT monitoring and root cause analysis. In a 2 year period a total of 75,499 specimens of outdoor patient department were monitor, of this a total of 4,142 specimens exceeded TAT. With consistent efforts to monitor, root cause analysis and corrective measures, we are able to decreased the specimens exceeding TAT from 7-8 to 3.7 %. Though it is difficult task to monitor TAT with the help of laboratory information system, real time documentation and authentic data retrievable, along with identification of causes for delays and its remedial measures, improve laboratory TAT and thus patient satisfaction.

  10. Low cost self-made pressure distribution sensors for ergonomic chair: Are they suitable for posture monitoring?

    PubMed

    Martinaitis, Arnas; Daunoraviciene, Kristina

    2018-05-18

    Long sitting causes many health problems for people. Healthy sitting monitoring systems, like real-time pressure distribution measuring, is in high demand and many methods of posture recognition were developed. Such systems are usually expensive and hardly available for the regular user. The aim of study is to develop low cost but sensitive enough pressure sensors and posture monitoring system. New self-made pressure sensors have been developed and tested, and prototype of pressure distribution measuring system was designed. Sensors measured at average noise amplitude of a = 56 mV (1.12%), average variation in sequential measurements of the same sensor s = 17 mV (0.34%). Signal variability between sensors averaged at 100 mV (2.0%). Weight to signal dependency graph was measured and hysteresis calculated. Results suggested the use of total sixteen sensors for posture monitoring system with accuracy of < 1.5% after relaxation and repeatability of around 2%. Results demonstrate that hand-made sensor sensitivity and repeatability are acceptable for posture monitoring, and it is possible to build low cost pressure distribution measurement system with graphical visualization without expensive equipment or complicated software.

  11. Development of on-line monitoring system for Nuclear Power Plant (NPP) using neuro-expert, noise analysis, and modified neural networks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Subekti, M.; Center for Development of Reactor Safety Technology, National Nuclear Energy Agency of Indonesia, Puspiptek Complex BO.80, Serpong-Tangerang, 15340; Ohno, T.

    2006-07-01

    The neuro-expert has been utilized in previous monitoring-system research of Pressure Water Reactor (PWR). The research improved the monitoring system by utilizing neuro-expert, conventional noise analysis and modified neural networks for capability extension. The parallel method applications required distributed architecture of computer-network for performing real-time tasks. The research aimed to improve the previous monitoring system, which could detect sensor degradation, and to perform the monitoring demonstration in High Temperature Engineering Tested Reactor (HTTR). The developing monitoring system based on some methods that have been tested using the data from online PWR simulator, as well as RSG-GAS (30 MW research reactormore » in Indonesia), will be applied in HTTR for more complex monitoring. (authors)« less

  12. To track or not to track: user reactions to concepts in longitudinal health monitoring.

    PubMed

    Beaudin, Jennifer S; Intille, Stephen S; Morris, Margaret E

    2006-01-01

    Advances in ubiquitous computing, smart homes, and sensor technologies enable novel, longitudinal health monitoring applications in the home. Many home monitoring technologies have been proposed to detect health crises, support aging-in-place, and improve medical care. Health professionals and potential end users in the lay public, however, sometimes question whether home health monitoring is justified given the cost and potential invasion of privacy. The aim of the study was to elicit specific feedback from health professionals and laypeople about how they might use longitudinal health monitoring data for proactive health and well-being. Interviews were conducted with 8 health professionals and 26 laypeople. Participants were asked to evaluate mock data visualization displays that could be generated by novel home monitoring systems. The mock displays were used to elicit reactions to longitudinal monitoring in the home setting as well as what behaviors, events, and physiological indicators people were interested in tracking. Based on the qualitative data provided by the interviews, lists of benefits of and concerns about health tracking from the perspectives of the practitioners and laypeople were compiled. Variables of particular interest to the interviewees, as well as their specific ideas for applications of collected data, were documented. Based upon these interviews, we recommend that ubiquitous "monitoring" systems may be more readily adopted if they are developed as tools for personalized, longitudinal self-investigation that help end users learn about the conditions and variables that impact their social, cognitive, and physical health.

  13. Study design and rationale for biomedical shirt-based electrocardiography monitoring in relevant clinical situations: ECG-shirt study.

    PubMed

    Balsam, Paweł; Lodziński, Piotr; Tymińska, Agata; Ozierański, Krzysztof; Januszkiewicz, Łukasz; Główczyńska, Renata; Wesołowska, Katarzyna; Peller, Michał; Pietrzak, Radosław; Książczyk, Tomasz; Borodzicz, Sonia; Kołtowski, Łukasz; Borkowski, Mariusz; Werner, Bożena; Opolski, Grzegorz; Grabowski, Marcin

    2018-01-01

    Today, the main challenge for researchers is to develop new technologies which may help to improve the diagnoses of cardiovascular disease (CVD), thereby reducing healthcare costs and improving the quality of life for patients. This study aims to show the utility of biomedical shirt-based electrocardiography (ECG) monitoring of patients with CVD in different clinical situations using the Nuubo® ECG (nECG) system. An investigator-initiated, multicenter, prospective observational study was carried out in a cardiology (adult and pediatric) and cardiac rehabilitation wards. ECG monitoring was used with the biomedical shirt in the following four independent groups of patients: 1) 30 patients after pulmonary vein isolation (PVI), 2) 30 cardiac resynchronization therapy (CRT) recipients, 3) 120 patients during cardiac rehabilitation after myocardial infarction, and 4) 40 pediatric patients with supraventricular tachycardia (SVT) before electrophysiology study. Approval for all study groups was obtained from the institutional review board. The biomedical shirt captures the electrocardiographic signal via textile electrodes integrated into a garment. The software allows the visualization and analysis of data such as ECG, heart rate, arrhythmia detecting algorithm and relative position of the body is captured by an electronic device. The major advantages of the nECG system are continuous ECG monitoring during daily activities, high quality of ECG recordings, as well as assurance of a proper adherence due to adequate comfort while wearing the shirt. There are only a few studies that have examined wearable systems, especially in pediatric populations. This study is registered in ClinicalTrials.gov: Identifier NCT03068169. (Cardiol J 2018; 25, 1: 52-59).

  14. Variation in monitoring and treatment policies for intracranial hypertension in traumatic brain injury: a survey in 66 neurotrauma centers participating in the CENTER-TBI study.

    PubMed

    Cnossen, Maryse C; Huijben, Jilske A; van der Jagt, Mathieu; Volovici, Victor; van Essen, Thomas; Polinder, Suzanne; Nelson, David; Ercole, Ari; Stocchetti, Nino; Citerio, Giuseppe; Peul, Wilco C; Maas, Andrew I R; Menon, David; Steyerberg, Ewout W; Lingsma, Hester F

    2017-09-06

    No definitive evidence exists on how intracranial hypertension should be treated in patients with traumatic brain injury (TBI). It is therefore likely that centers and practitioners individually balance potential benefits and risks of different intracranial pressure (ICP) management strategies, resulting in practice variation. The aim of this study was to examine variation in monitoring and treatment policies for intracranial hypertension in patients with TBI. A 29-item survey on ICP monitoring and treatment was developed on the basis of literature and expert opinion, and it was pilot-tested in 16 centers. The questionnaire was sent to 68 neurotrauma centers participating in the Collaborative European Neurotrauma Effectiveness Research in Traumatic Brain Injury (CENTER-TBI) study. The survey was completed by 66 centers (97% response rate). Centers were mainly academic hospitals (n = 60, 91%) and designated level I trauma centers (n = 44, 67%). The Brain Trauma Foundation guidelines were used in 49 (74%) centers. Approximately 90% of the participants (n = 58) indicated placing an ICP monitor in patients with severe TBI and computed tomographic abnormalities. There was no consensus on other indications or on peri-insertion precautions. We found wide variation in the use of first- and second-tier treatments for elevated ICP. Approximately half of the centers were classified as using a relatively aggressive approach to ICP monitoring and treatment (n = 32, 48%), whereas the others were considered more conservative (n = 34, 52%). Substantial variation was found regarding monitoring and treatment policies in patients with TBI and intracranial hypertension. The results of this survey indicate a lack of consensus between European neurotrauma centers and provide an opportunity and necessity for comparative effectiveness research.

  15. SCORHE: A novel and practical approach to video monitoring of laboratory mice housed in vivarium cage racks

    PubMed Central

    Dennis, John U.; Krynitsky, Jonathan; Garmendia-Cedillos, Marcial; Swaroop, Kanchan; Malley, James D.; Pajevic, Sinisa; Abuhatzira, Liron; Bustin, Michael; Gillet, Jean-Pierre; Gottesman, Michael M.; Mitchell, James B.; Pohida, Thomas J.

    2015-01-01

    The System for Continuous Observation of Rodents in Home-cage Environment (SCORHE) was developed to demonstrate the viability of compact and scalable designs for quantifying activity levels and behavior patterns for mice housed within a commercial ventilated cage rack. The SCORHE in-rack design provides day- and night-time monitoring with the consistency and convenience of the home-cage environment. The dual-video camera custom hardware design makes efficient use of space, does not require home-cage modification, and is animal-facility user-friendly. Given the system’s low cost and suitability for use in existing vivariums without modification to the animal husbandry procedures or housing setup, SCORHE opens up the potential for the wider use of automated video monitoring in animal facilities. SCORHE’s potential uses include day-to-day health monitoring, as well as advanced behavioral screening and ethology experiments, ranging from the assessment of the short- and long-term effects of experimental cancer treatments to the evaluation of mouse models. When used for phenotyping and animal model studies, SCORHE aims to eliminate the concerns often associated with many mouse-monitoring methods, such as circadian rhythm disruption, acclimation periods, lack of night-time measurements, and short monitoring periods. Custom software integrates two video streams to extract several mouse activity and behavior measures. Studies comparing the activity levels of ABCB5 knockout and HMGN1 overexpresser mice with their respective C57BL parental strains demonstrate SCORHE’s efficacy in characterizing the activity profiles for singly- and doubly-housed mice. Another study was conducted to demonstrate the ability of SCORHE to detect a change in activity resulting from administering a sedative. PMID:24706080

  16. SCORHE: a novel and practical approach to video monitoring of laboratory mice housed in vivarium cage racks.

    PubMed

    Salem, Ghadi H; Dennis, John U; Krynitsky, Jonathan; Garmendia-Cedillos, Marcial; Swaroop, Kanchan; Malley, James D; Pajevic, Sinisa; Abuhatzira, Liron; Bustin, Michael; Gillet, Jean-Pierre; Gottesman, Michael M; Mitchell, James B; Pohida, Thomas J

    2015-03-01

    The System for Continuous Observation of Rodents in Home-cage Environment (SCORHE) was developed to demonstrate the viability of compact and scalable designs for quantifying activity levels and behavior patterns for mice housed within a commercial ventilated cage rack. The SCORHE in-rack design provides day- and night-time monitoring with the consistency and convenience of the home-cage environment. The dual-video camera custom hardware design makes efficient use of space, does not require home-cage modification, and is animal-facility user-friendly. Given the system's low cost and suitability for use in existing vivariums without modification to the animal husbandry procedures or housing setup, SCORHE opens up the potential for the wider use of automated video monitoring in animal facilities. SCORHE's potential uses include day-to-day health monitoring, as well as advanced behavioral screening and ethology experiments, ranging from the assessment of the short- and long-term effects of experimental cancer treatments to the evaluation of mouse models. When used for phenotyping and animal model studies, SCORHE aims to eliminate the concerns often associated with many mouse-monitoring methods, such as circadian rhythm disruption, acclimation periods, lack of night-time measurements, and short monitoring periods. Custom software integrates two video streams to extract several mouse activity and behavior measures. Studies comparing the activity levels of ABCB5 knockout and HMGN1 overexpresser mice with their respective C57BL parental strains demonstrate SCORHE's efficacy in characterizing the activity profiles for singly- and doubly-housed mice. Another study was conducted to demonstrate the ability of SCORHE to detect a change in activity resulting from administering a sedative.

  17. On the rapid and efficient divulgation of monitoring results in landslide emergency scenarios

    NASA Astrophysics Data System (ADS)

    Giordan, Daniele; Allasia, Paolo; Manconi, Andrea; Bertolo, Davide

    2014-05-01

    In last decades, the availability of several technological systems to monitor different physical parameters that can be used to control a landslide evolution recorded an exponential growth. In particular, surficial and deep-seated displacements of an instable area, as well as meteorological or hydrological parameters can be nowadays acquired with high spatial and temporal resolutions. As a consequence, the application of complex monitoring systems produces large amounts of data. While this can be considered an important progress in the field of landslide monitoring applications, the availability of large volumes of high resolution and multiparametric information implies important challenges. In this context, two main criticalities are: i) the integrated management of dataset produced by different monitoring systems and ii) the correct divulgation of monitoring results. In this work, we present the results of a real case-study relevant to a complex emergency scenario, i.e. the Mont de La Saxe landslide, a large rockslide (with an estimated volume or more than 8 million of cubic meters) that threatens La Palud and Entrèves hamlets in the Courmayeur municipality (Aosta Valley, Italy). We developed a web-based system based on the ADVICE algorithm (Allasia et al., 2013) in order to manage several data sources. The system collects, analyzes and publishes the results obtained by monitoring instrumentations in near-real-time at each new measurement cycle. Moreover, by collecting all the data in an unique web-based platform reduces the problems of compatibility amongst different monitoring systems, which usually rely on customized software for the data processing, delaying the comparative analysis comparison amongst different data sources. This is indeed a crucial task for decision makers, in particular during the emergency phases. In addition, by using the developed web-based platform we aimed at coping with another important task, often not considered and/or underestimated, relevant to the landslide monitoring results, i.e. the divulgation. Starting from the analysis of different landslide scenarios, we identified and classified people belonging to emergency management teams into several categories according to their role, the level of knowledge of landslides, and/or of monitoring systems. Our aim is to define standards to share the monitoring results, in order to disseminate the information about the recent evolution of the landslide, as well as the level of criticality, within all the people involved (scientists, technicians, civil protection operators, decision makers, politicians, press, population). This task is particularly critical during the emergency phases, when a correct understanding of the situation is (in particular for the population) the first step for a successful emergency management. References: Allasia, P.; Manconi, A.; Giordan, D.; Baldo, M.; Lollino, G. ADVICE: A New Approach for Near-Real-Time Monitoring of Surface Displacements in Landslide Hazard Scenarios. Sensors 2013, 13, 8285-8302.

  18. The FOBIMO (FOraminiferal BIo-MOnitoring) initiative—Towards a standardised protocol for soft-bottom benthic foraminiferal monitoring studies

    USGS Publications Warehouse

    Schoenfeld, Joachim; Alve, Elisabeth; Geslin, Emmanuelle; Jorissen, Frans; Korsun, Sergei; Spezzaferri, Silva; Abramovich, Sigal; Almogi-Labin, Ahuva; Armynot du Chatelet, Eric; Barras, Christine; Bergamin, Luisa; Bicchi, Erica; Bouchet, Vincent; Cearreta, Alejandro; Di Bella, Letizia; Dijkstra, Noortje; Trevisan Disaro, Sibelle; Ferraro, Luciana; Frontalini, Fabrizio; Gennari, Giordana; Golikova, Elena; Haynert, Kristin; Hess, Silvia; Husum, Katrine; Martins, Virginia; McGann, Mary; Oron, Shai; Romano, Elena; Mello Sousa, Silvia; Tsujimoto, Akira

    2012-01-01

    The European Community Marine Strategy Framework Directive (MSFD) was established to provide guidelines for monitoring the quality of marine ecosystems. Monitoring the status of marine environments is traditionally based on macrofauna surveys, for which standardised methods have been established. Benthic foraminifera are also good indicators of environmental status because of their fast turnover rates, high degree of specialisation, and the preservation of dead assemblages in the fossil record. In spite of the growing interest in foraminiferal bio-monitoring during the last decades, no standardised methodology has been proposed until today. The aim of the FOraminiferal BIo-MOnitoring (FOBIMO) expert workshop, held in June 2011 at Fribourg, Switzerland, which assembled 37 scientists from 24 research groups and 13 countries, was to develop a suite of standard methods. This paper presents the main outcome of the workshop, a list of motivated recommendations with respect to sampling devices, sample storage, treatment, faunal analysis and documentation. Our recommendations fulfil the criteria imposed both by scientific rigour and by the practical limitations of routine studies. Hence, our aim is to standardise methodologies used in bio-monitoring only and not to limit the use of different methods in pure scientific studies. Unless otherwise stated, all recommendations concern living (stained) benthic foraminiferal assemblages. We have chosen to propose two types of recommendations. Mandatory recommendations have to be followed if a study wants to qualify as sound and compatible to the norms. The most important of these recommendations are the interval from 0 to 1 cm below the sediment surface has to be sampled, and an interface corer or box corer that keeps the sediment surface intact is to be used for offshore surveys. A grab sampler must not be deployed in soft sediments. Three replicate samples are to be taken and analysed separately. Samples are to be washed on a 63-μm screen, and the living benthic foraminiferal fauna of the > 125 μm fraction is to be analysed. Splits are to be picked and counted entirely, and all counted foraminifera from at least one replicate per station have to be stored in micropalaeontological slides. Census data, supplementary laboratory data and microslides have to be archived. Advisory recommendations are to sample in autumn, to have a sample size of 50 cm2 or a tube of 8 cm inner diameter, to use > 70% ethanol as a preservative, rose Bengal at a concentration of 2 grams per litre for staining, and a staining time of at least 14 days. The split size should be defined by a target value of 300 specimens, heavy liquid separation should be avoided, and the 63–125 μm fraction or deeper sediment levels may be considered in some environments. We are convinced that the application of this protocol by a large number of scientists is a necessary first step to a general acceptance of benthic foraminifera as a reliable tool in bio-monitoring studies.

  19. Framework for Structural Online Health Monitoring of Aging and Degradation of Secondary Systems due to some Aspects of Erosion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gribok, Andrei; Patnaik, Sobhan; Williams, Christian

    This report describes the current state of research related to critical aspects of erosion and selected aspects of degradation of secondary components in nuclear power plants. The report also proposes a framework for online health monitoring of aging and degradation of secondary components. The framework consists of an integrated multi-sensor modality system which can be used to monitor different piping configurations under different degradation conditions. The report analyses the currently known degradation mechanisms and available predictive models. Based on this analysis, the structural health monitoring framework is proposed. The Light Water Reactor Sustainability Program began to evaluate technologies that couldmore » be used to perform online monitoring of piping and other secondary system structural components in commercial NPPs. These online monitoring systems have the potential to identify when a more detailed inspection is needed using real-time measurements, rather than at a pre-determined inspection interval. This transition to condition-based, risk informed automated maintenance will contribute to a significant reduction of operations and maintenance costs that account for the majority of nuclear power generation costs. There is unanimous agreement between industry experts and academic researchers that identifying and prioritizing inspection locations in secondary piping systems (for example, in raw water piping or diesel piping) would eliminate many excessive in-service inspections. The proposed structural health monitoring framework takes aim at answering this challenge by combining long-range guided wave technologies with other monitoring techniques, which can significantly increase the inspection length and pinpoint the locations that degraded the most. More widely, the report suggests research efforts aimed at developing, validating, and deploying online corrosion monitoring techniques for complex geometries, which are pervasive in NPPs.« less

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Costa, Mafalda T., E-mail: mafaldatcosta@gmail.com; Carolino, Elisabete, E-mail: lizcarolino@gmail.com; Oliveira, Teresa A., E-mail: teresa.oliveira@uab.pt

    In water supply systems with distribution networkthe most critical aspects of control and Monitoring of water quality, which generates crises system, are the effects of cross-contamination originated by the network typology. The classics of control of quality systems through the application of Shewhart charts are generally difficult to manage in real time due to the high number of charts that must be completed and evaluated. As an alternative to the traditional control systems with Shewhart charts, this study aimed to apply a simplified methodology of a monitoring plan quality parameters in a drinking water distribution, by applying Hotelling’s T{sup 2}more » charts and supplemented with Shewhart charts with Bonferroni limits system, whenever instabilities with processes were detected.« less

  1. Analysis of Benefits and Pitfalls of Satellite SAR for Coastal Area Monitoring

    NASA Astrophysics Data System (ADS)

    Nunziata, F.; Buono, A.; Mgliaccio, M.; Li, X.; Wei, Y.

    2016-08-01

    This study aims at describing the outcomes of the Dragon-3 project no. 10689. The undertaken activities deal with coastal area monitoring and they include sea pollution and coastline extraction. The key remote sensing tool is the Synthetic Aperture Radar (SAR) that provides fine resolution images of the microwave reflectivity of the observed scene. However, the interpretation of SAR images is not at all straightforward and all the above-mentioned coastal area applications cannot be easily addressed using single-polarization SAR. Hence, the main outcome of this project is investigating the capability of multi-polarization SAR measurements to generate added-vale product in the frame of coastal area management.

  2. A study to assess the long-term stability of the ionization chamber reference system in the LNMRI

    NASA Astrophysics Data System (ADS)

    Trindade Filho, O. L.; Conceição, D. A.; da Silva, C. J.; Delgado, J. U.; de Oliveira, A. E.; Iwahara, A.; Tauhata, L.

    2018-03-01

    Ionization chambers are used as secondary standard in order to maintain the calibration factors of radionuclides in the activity measurements in metrology laboratories. Used as radionuclide calibrator in nuclear medicine clinics to control dose in patients, its long-term performance is not evaluated systematically. A methodology for long-term evaluation for its stability is monitored and checked. Historical data produced monthly of 2012 until 2017, by an ionization chamber, electrometer and 226Ra, were analyzed via control chart, aiming to follow the long-term performance. Monitoring systematic errors were consistent within the limits of control, demonstrating the quality of measurements in compliance with ISO17025.

  3. 6th Annual Symposium on Self-Monitoring of Blood Glucose (SMBG) Applications and Beyond, April 25–27, 2013, Riga, Latvia

    PubMed Central

    Schlaeger, Christof; Hinzmann, Rolf

    2013-01-01

    Abstract International experts in the fields of diabetes, diabetes technology, endocrinology, and pediatrics gathered for the 6th Annual Symposium on Self-Monitoring of Blood Glucose (SMBG) Applications and beyond. The aim of this meeting was to continue setting up a global network of experts in this field and provide an international platform for exchange of ideas to improve life for people with diabetes. The 2013 meeting comprised a comprehensive scientific program, parallel interactive workshops, and two keynote lectures. All these discussions were intended to help identify gaps and areas where further scientific work and clinical studies are warranted. PMID:24074038

  4. Cancer incidence and incidence rates in Japan in 2009: a study of 32 population-based cancer registries for the Monitoring of Cancer Incidence in Japan (MCIJ) project.

    PubMed

    Hori, Megumi; Matsuda, Tomohiro; Shibata, Akiko; Katanoda, Kota; Sobue, Tomotaka; Nishimoto, Hiroshi

    2015-09-01

    The Japan Cancer Surveillance Research Group aimed to estimate the cancer incidence in Japan in 2009 based on data collected from 32 of 37 population-based cancer registries, as part of the Monitoring of Cancer Incidence in Japan (MCIJ) project. The incidence of only primary invasive cancer in Japan for 2009 was estimated to be 775 601. Stomach cancer and breast cancer were the leading types of cancer in males and females, respectively. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Combined phosphorescence-holographic approach for singlet oxygen detection in biological media

    NASA Astrophysics Data System (ADS)

    Semenova, I. V.; Belashov, A. V.; Beltukova, D. M.; Petrov, N. V.; Vasyutinskii, O. S.

    2015-06-01

    The paper presents a novel combined approach aimed to detect and monitor singlet oxygen molecules in biological specimens by means of the simultaneous recording and monitoring of their deactivation dynamics in the two complementary channels: radiative and nonradiative. The approach involves both the direct registration of phosphorescence at the wavelength of about 1270 nm caused by radiative relaxation of excited singlet oxygen molecules and holographic recording of thermal disturbances in the medium produced by their nonradiative relaxation. The data provides a complete set of information on singlet oxygen location and dynamics in the medium. The approach was validated in the case study of photosensitized generation of singlet oxygen in onion cell structures.

  6. Smartphone electrographic monitoring for atrial fibrillation in acute ischemic stroke and transient ischemic attack.

    PubMed

    Tu, Hans T; Chen, Ziyuan; Swift, Corey; Churilov, Leonid; Guo, Ruibing; Liu, Xinfeng; Jannes, Jim; Mok, Vincent; Freedman, Ben; Davis, Stephen M; Yan, Bernard

    2017-10-01

    Rationale Paroxysmal atrial fibrillation is a common and preventable cause of devastating strokes. However, currently available monitoring methods, including Holter monitoring, cardiac telemetry and event loop recorders, have drawbacks that restrict their application in the general stroke population. AliveCor™ heart monitor, a novel device that embeds miniaturized electrocardiography (ECG) in a smartphone case coupled with an application to record and diagnose the ECG, has recently been shown to provide an accurate and sensitive single lead ECG diagnosis of atrial fibrillation. This device could be used by nurses to record a 30-s ECG instead of manual pulse taking and automatically provide a diagnosis of atrial fibrillation. Aims To compare the proportion of patients with paroxysmal atrial fibrillation detected by AliveCor™ ECG monitoring with current standard practice. Sample size 296 Patients. Design Consecutive ischemic stroke and transient ischemic attack patients presenting to participating stroke units without known atrial fibrillation will undergo intermittent AliveCor™ ECG monitoring administered by nursing staff at the same frequency as the vital observations of pulse and blood pressure until discharge, in addition to the standard testing paradigm of each participating stroke unit to detect paroxysmal atrial fibrillation. Study outcome Proportion of patients with paroxysmal atrial fibrillation detected by AliveCor™ ECG monitoring compared to 12-lead ECG, 24-h Holter monitoring and cardiac telemetry. Discussion Use of AliveCor™ heart monitor as part of routine stroke unit nursing observation has the potential to be an inexpensive non-invasive method to increase paroxysmal atrial fibrillation detection, leading to improvement in stroke secondary prevention.

  7. Smart homes and home health monitoring technologies for older adults: A systematic review.

    PubMed

    Liu, Lili; Stroulia, Eleni; Nikolaidis, Ioanis; Miguel-Cruz, Antonio; Rios Rincon, Adriana

    2016-07-01

    Around the world, populations are aging and there is a growing concern about ways that older adults can maintain their health and well-being while living in their homes. The aim of this paper was to conduct a systematic literature review to determine: (1) the levels of technology readiness among older adults and, (2) evidence for smart homes and home-based health-monitoring technologies that support aging in place for older adults who have complex needs. We identified and analyzed 48 of 1863 relevant papers. Our analyses found that: (1) technology-readiness level for smart homes and home health monitoring technologies is low; (2) the highest level of evidence is 1b (i.e., one randomized controlled trial with a PEDro score ≥6); smart homes and home health monitoring technologies are used to monitor activities of daily living, cognitive decline and mental health, and heart conditions in older adults with complex needs; (3) there is no evidence that smart homes and home health monitoring technologies help address disability prediction and health-related quality of life, or fall prevention; and (4) there is conflicting evidence that smart homes and home health monitoring technologies help address chronic obstructive pulmonary disease. The level of technology readiness for smart homes and home health monitoring technologies is still low. The highest level of evidence found was in a study that supported home health technologies for use in monitoring activities of daily living, cognitive decline, mental health, and heart conditions in older adults with complex needs. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. Jewel scarabs (Chrysina sp.) in Honduras: key species for cloud forest conservation monitoring?

    PubMed

    Jocque, M; Vanhove, M P M; Creedy, T J; Burdekin, O; Nuñez-Miño, J M; Casteels, J

    2013-01-01

    Jewel scarabs, beetles in the genus Chrysina Kirby (Coleoptera: Rutelinae: Scarabaeidae), receive their name from the bright, often gold, green elytra that reflect light like a precious stone. Jewel scarabs are commonly observed at light traps in Mesoamerican cloud forests, and their association with mountain forests makes them potentially interesting candidates for cloud forest conservation monitoring. The absence of survey protocols and identification tools, and the little ecological information available are barriers. In the present study, collection of Chrysina species assembled during biodiversity surveys by Operation Wallacea in Cusuco National Park (CNP), Honduras, were studied. The aim of this overview is to provide an easy to use identification tool for in the field, hopefully stimulating data collection on these beetles. Based on the data associated with the collection localities, elevation distribution of the species in the park was analyzed. The limited data points available were complemented with potential distribution areas generated with distribution models based on climate and elevation data. This study is aimed at initializing the development of a survey protocol for Chrysina species that can be used in cloud forest conservation monitoring throughout Central America. A list of Chrysina species recorded from Honduras so far is provided. The six identified and one unidentified species recorded from CNP are easy to identify in the field based on color and straightforward morphological characteristics. Literature research revealed ten species currently recorded from Honduras. This low species richness in comparison with surrounding Central American countries indicates the poor knowledge of this genus in Honduras. Chrysina species richness in CNP increases with elevation, thereby making the genus one of a few groups of organisms where this correlation is observed, and rendering it a suitable invertebrate representative for cloud forest habitats in Central America.

  9. Earthquake forecasting studies using radon time series data in Taiwan

    NASA Astrophysics Data System (ADS)

    Walia, Vivek; Kumar, Arvind; Fu, Ching-Chou; Lin, Shih-Jung; Chou, Kuang-Wu; Wen, Kuo-Liang; Chen, Cheng-Hong

    2017-04-01

    For few decades, growing number of studies have shown usefulness of data in the field of seismogeochemistry interpreted as geochemical precursory signals for impending earthquakes and radon is idendified to be as one of the most reliable geochemical precursor. Radon is recognized as short-term precursor and is being monitored in many countries. This study is aimed at developing an effective earthquake forecasting system by inspecting long term radon time series data. The data is obtained from a network of radon monitoring stations eastblished along different faults of Taiwan. The continuous time series radon data for earthquake studies have been recorded and some significant variations associated with strong earthquakes have been observed. The data is also examined to evaluate earthquake precursory signals against environmental factors. An automated real-time database operating system has been developed recently to improve the data processing for earthquake precursory studies. In addition, the study is aimed at the appraisal and filtrations of these environmental parameters, in order to create a real-time database that helps our earthquake precursory study. In recent years, automatic operating real-time database has been developed using R, an open source programming language, to carry out statistical computation on the data. To integrate our data with our working procedure, we use the popular and famous open source web application solution, AMP (Apache, MySQL, and PHP), creating a website that could effectively show and help us manage the real-time database.

  10. A Study on the Optimal Positions of ECG Electrodes in a Garment for the Design of ECG-Monitoring Clothing for Male.

    PubMed

    Cho, Hakyung; Lee, Joo Hyeon

    2015-09-01

    Smart clothing is a sort of wearable device used for ubiquitous health monitoring. It provides comfort and efficiency in vital sign measurements and has been studied and developed in various types of monitoring platforms such as T-shirt and sports bra. However, despite these previous approaches, smart clothing for electrocardiography (ECG) monitoring has encountered a serious shortcoming relevant to motion artifacts caused by wearer movement. In effect, motion artifacts are one of the major problems in practical implementation of most wearable health-monitoring devices. In the ECG measurements collected by a garment, motion artifacts are usually caused by improper location of the electrode, leading to lack of contact between the electrode and skin with body motion. The aim of this study was to suggest a design for ECG-monitoring clothing contributing to reduction of motion artifacts. Based on the clothing science theory, it was assumed in this study that the stability of the electrode in a dynamic state differed depending on the electrode location in an ECG-monitoring garment. Founded on this assumption, effects of 56 electrode positions were determined by sectioning the surface of the garment into grids with 6 cm intervals in the front and back of the bodice. In order to determine the optimal locations of the ECG electrodes from the 56 positions, ECG measurements were collected from 10 participants at every electrode position in the garment while the wearer was in motion. The electrode locations indicating both an ECG measurement rate higher than 80.0 % and a large amplitude during motion were selected as the optimal electrode locations. The results of this analysis show four electrode locations with consistently higher ECG measurement rates and larger amplitudes amongst the 56 locations. These four locations were abstracted to be least affected by wearer movement in this research. Based on this result, a design of the garment-formed ECG monitoring platform reflecting the optimal positions of the electrode was suggested.

  11. A validation study comparing self-reported travel diaries and objective data obtained from in-vehicle monitoring devices in older drivers with bilateral cataract.

    PubMed

    Agramunt, Seraina; Meuleners, Lynn; Chow, Kyle Chi; Ng, Jonathon Q; Morlet, Nigel

    2017-09-01

    Advances in technology have made it possible to examine real-world driving using naturalistic data obtained from in-vehicle monitoring devices. These devices overcome the weaknesses of self-report methods and can provide comprehensive insights into driving exposure, habits and practices of older drivers. The aim of this study is to compare self-reported and objectively measured driving exposure, habits and practices using a travel diary and an in-vehicle driver monitoring device in older drivers with bilateral cataract. A cross-sectional study was undertaken. Forty seven participants aged 58-89 years old (mean=74.1; S.D.=7.73) were recruited from three eye clinics over a one year period. Data collection consisted of a cognitive test, a researcher-administered questionnaire, a travel diary and an in-vehicle monitoring device. Participants' driving exposure and patterns were recorded for one week using in-vehicle monitoring devices. They also completed a travel diary each time they drove a motor vehicle as the driver. Paired t-tests were used to examine differences/agreement between the two instruments under different driving circumstances. The data from the older drivers' travel diaries significantly underestimated the number of overall trips (p<0.001), weekend trips (p=0.002) and trips during peak hour (p=0.004). The travel diaries also significantly overestimated overall driving duration (p<0.001) and weekend driving duration (p=0.003), compared to the data obtained from the in-vehicle monitoring devices. No significant differences were found between instruments for kilometres travelled under any of the driving circumstances. The results of this study found that relying solely on self-reported travel diaries to assess driving outcomes may not be accurate, particularly for estimates of the number of trips made and duration of trips. The clear advantages of using in-vehicle monitoring devices over travel diaries to monitor driving habits and exposure among an older population are evident. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Balanced: a randomised trial examining the efficacy of two self-monitoring methods for an app-based multi-behaviour intervention to improve physical activity, sitting and sleep in adults.

    PubMed

    Duncan, Mitch J; Vandelanotte, Corneel; Trost, Stewart G; Rebar, Amanda L; Rogers, Naomi; Burton, Nicola W; Murawski, Beatrice; Rayward, Anna; Fenton, Sasha; Brown, Wendy J

    2016-07-30

    Many adults are insufficiently physically active, have prolonged sedentary behaviour and report poor sleep. These behaviours can be improved by interventions that include education, goal setting, self-monitoring, and feedback strategies. Few interventions have explicitly targeted these behaviours simultaneously or examined the relative efficacy of different self-monitoring methods. This study aims to compare the efficacy of two self-monitoring methods in an app-based multi-behaviour intervention to improve objectively measured physical activity, sedentary, and sleep behaviours, in a 9 week 2-arm randomised trial. Participants will be adults (n = 64) who report being physically inactive, sitting >8 h/day and frequent insufficient sleep (≥14 days out of last 30). The "Balanced" intervention is delivered via a smartphone 'app', and includes education materials (guidelines, strategies to promote change in behaviour), goal setting, self-monitoring and feedback support. Participants will be randomly allocated to either a device-entered or user-entered self-monitoring method. The device-entered group will be provided with a activity tracker to self-monitor behaviours. The user-entered group will recall and manually record behaviours. Assessments will be conducted at 0, 3, 6, and 9 weeks. Physical activity, sedentary behaviour and sleep-wake behaviours will be measured using the wrist worn Geneactiv accelerometer. Linear mixed models will be used to examine differences between groups and over time using an alpha of 0.01. This study will evaluate an app-based multi-behavioural intervention to improve physical activity, sedentary behaviour and sleep; and the relative efficacy of two different approaches to self-monitoring these behaviours. Outcomes will provide information to inform future interventions and self-monitoring targeting these behaviours. ACTRN12615000182594 (Australian New Zealand Clinical Trials Registry. Registry URL: www.anzctr.org.au ; registered prospectively on 25 February 2015).

  13. Key beliefs influencing young drivers' engagement with social interactive technology on their smartphones: A qualitative study.

    PubMed

    Gauld, Cassandra S; Lewis, Ioni M; White, Katherine M; Watson, Barry

    2016-01-01

    The main aim of this study was to identify young drivers' underlying beliefs (i.e., behavioral, normative, and control) regarding initiating, monitoring/reading, and responding to social interactive technology (i.e., functions on a Smartphone that allow the user to communicate with other people). This qualitative study was a beliefs elicitation study in accordance with the theory of planned behavior and sought to elicit young drivers' behavioral (i.e., advantages, disadvantages), normative (i.e., who approves, who disapproves), and control beliefs (i.e., barriers, facilitators) that underpin social interactive technology use while driving. Young drivers (N = 26) aged 17 to 25 years took part in an interview or focus group discussion. Though differences emerged between the 3 behaviors of initiating, monitoring/reading, and responding for each of the behavioral, normative, and control belief categories, the strongest distinction was within the behavioral beliefs category (e.g., communicating with the person that they were on the way to meet was an advantage of initiating; being able to determine whether to respond was an advantage of monitoring/reading; and communicating with important people was an advantage of responding). Normative beliefs were similar for initiating and responding behaviors (e.g., friends and peers more likely to approve than other groups) and differences emerged for monitoring/reading (e.g., parents were more likely to approve of this behavior than initiating and responding). For control beliefs, there were differences between the beliefs regarding facilitators of these behaviors (e.g., familiar roads and conditions facilitated initiating; having audible notifications of an incoming communication facilitated monitoring/reading; and receiving a communication of immediate importance facilitated responding); however, the control beliefs that presented barriers were consistent across the 3 behaviors (e.g., difficult traffic/road conditions). The current study provides an important addition to the extant literature and supports emerging research that suggests that initiating, monitoring/reading, and responding may indeed be distinct behaviors with different underlying motivations.

  14. Dermal uptake and excretion of 4,4'-methylenedianiline during rotor blade production in helicopter industry--an intervention study.

    PubMed

    Weiss, Tobias; Schuster, Hubert; Müller, Johannes; Schaller, Karl-Heinz; Drexler, Hans; Angerer, Jürgen; Käfferlein, Heiko U

    2011-10-01

    Workers using composite materials by fibre reinforced laminate technology are exposed to 4,4'-methylenedianiline (MDA), a liver toxicant and suspected human carcinogen, during the production of rotor blades in helicopter industry. The aim of the study presented here was to assess the internal dose of MDA and the suitability of various personal protection measures at the workplace. Ambient monitoring and biological monitoring was carried out by analysing MDA in air and urine samples in seven workers of a highly specialized workplace (rotor blade production). Three different concepts of personal protection measures were applied to study the route of uptake and to evaluate strategies in decreasing workplace exposure. In addition, elimination kinetics of MDA was studied in three workers who were exposed to MDA on three consecutive working days. Ambient monitoring consistently provided air levels at or below the limit of quantification of 0.1 μg m(-3). Nevertheless, MDA was detected in 89% of all post-shift urine samples and median concentration was 4.2 μg l(-1). MDA in urine were >20 times higher than expected on data from ambient monitoring alone. A significant decrease in exposure could be achieved when workers have worn MDA-protective overalls in combination with MDA-protective gloves and a splash protection shield (from 9.8 μg l(-1) down to 3.7 μg l(-1)). The results show that MDA is taken up primarily via the skin at the workplaces under study. The excretion of MDA in urine was observed to be delayed after dermal exposure. Exposure assessment of MDA should be carried out by biological monitoring rather than ambient monitoring. For this purpose, urine samples midweek or at the end of the week should be used based on the observed delay in the excretion of MDA after dermal absorption. Uptake of MDA via the skin could not be completely avoided even if state-of-the-art personal protection measures were applied.

  15. Physical activity monitoring in patients with peripheral arterial disease: validation of an activity monitor.

    PubMed

    Fokkenrood, H J P; Verhofstad, N; van den Houten, M M L; Lauret, G J; Wittens, C; Scheltinga, M R M; Teijink, J A W

    2014-08-01

    The daily life physical activity (PA) of patients with peripheral arterial disease (PAD) may be severely hampered by intermittent claudication (IC). From a therapeutic, as well as research, point of view, it may be more relevant to determine improvement in PA as an outcome measure in IC. The aim of this study was to validate daily activities using a novel type of tri-axial accelerometer (Dynaport MoveMonitor) in patients with IC. Patients with IC were studied during a hospital visit. Standard activities (locomotion, lying, sitting, standing, shuffling, number of steps and "not worn" detection) were video recorded and compared with activities scored by the MoveMonitor. Inter-rater reliability (expressed in intraclass correlation coefficients [ICC]), sensitivity, specificity, and positive predictive values (PPV) were calculated for each activity. Twenty-eight hours of video observation were analysed (n = 21). Our video annotation method (the gold standard method) appeared to be accurate for most postures (ICC > 0.97), except for shuffling (ICC = 0.38). The MoveMonitor showed a high sensitivity (>86%), specificity (>91%), and PPV (>88%) for locomotion, lying, sitting, and "not worn" detection. Moderate accuracy was found for standing (46%), while shuffling appeared to be undetectable (18%). A strong correlation was found between video recordings and the MoveMonitor with regard to the calculation of the "number of steps" (ICC = 0.90). The MoveMonitor provides accurate information on a diverse set of postures, daily activities, and number of steps in IC patients. However, the detection of low amplitude movements, such as shuffling and "sitting to standing" transfers, is a matter of concern. This tool is useful in assessing the role of PA as a novel, clinically relevant outcome parameter in IC. Copyright © 2014 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  16. Cerebral hyperperfusion following carotid endarterectomy: diagnostic utility of intraoperative transcranial Doppler ultrasonography compared with single-photon emission computed tomography study.

    PubMed

    Ogasawara, Kuniaki; Inoue, Takashi; Kobayashi, Masakazu; Endo, Hidehoko; Yoshida, Kenji; Fukuda, Takeshi; Terasaki, Kazunori; Ogawa, Akira

    2005-02-01

    Cerebral hyperperfusion syndrome is a rare but serious complication of carotid endarterectomy (CEA). The aim of the present study was to determine whether intraoperative blood flow velocity (BFV) monitoring in the middle cerebral artery (MCA) by using transcranial Doppler ultrasonography (TCD) could be used as a reliable technique to detect cerebral hyperperfusion following CEA by comparing findings with those of brain single photon emission CT (SPECT). Intraoperative BFV monitoring was attempted in 67 patients undergoing CEA for treatment of ipsilateral internal carotid artery (ICA) stenosis (> or =70%). Cerebral blood flow (CBF) was also assessed using SPECT, which was performed before and immediately after CEA. Intraoperative BFV monitoring was achieved in 60 patients. Of the 60 patients, post-CEA hyperperfusion (CBF increase > or =100%, compared with preoperative values) was observed in six patients. The sensitivity, specificity, and positive predictive value of the BFV increases immediately after declamping of the ICA for detecting post-CEA hyperperfusion was 100%, 94% and 67%, respectively, with a cut-off point 2.0-fold that of preclamping BFV. The sensitivity and specificity of the BFV increases at the end of the procedure for detecting post-CEA hyperperfusion were 100% for both parameters, with cut-off points of 2.0- to 2.2-fold BFV of preclamping value. Hyperperfusion syndrome developed in two patients with post-CEA hyperperfusion, but intracerebral hemorrhage did not occur. In one of these two patients, BFV monitoring was not possible because of failure to obtain an adequate bone window. Intraoperative MCA BFV monitoring by using TCD is a less reliable method to detect cerebral hyperperfusion following CEA than postoperative MCA BFV monitoring, provided adequate monitoring can be achieved.

  17. Field evidence of biodegradation of N-Nitrosodimethylamine (NDMA) in groundwater with incidental and active recycled water recharge.

    PubMed

    Zhou, Quanlin; McCraven, Sally; Garcia, Julio; Gasca, Monica; Johnson, Theodore A; Motzer, William E

    2009-02-01

    Biodegradation of N-Nitrosodimethylamine (NDMA) has been found through laboratory incubation in unsaturated and saturated soil samples under both aerobic and anaerobic conditions. However, direct field evidence of in situ biodegradation in groundwater is very limited. This research aimed to evaluate biodegradation of NDMA in a large-scale groundwater system receiving recycled water as incidental and active recharge. NDMA concentrations in 32 monitoring and production wells with different screen intervals were monitored over a period of seven years. Groundwater monitoring was used to characterize changes in the magnitude and extent of NDMA in groundwater in response to seasonal hydrogeologic conditions and, more importantly, to significant concentration variations in effluent from water reclamation plants (associated with treatment-process changes). Extensive monitoring of NDMA concentrations and flow rates at effluent discharge locations and surface-water stations was also conducted to reasonably estimate mass loading through unlined river reaches to underlying groundwater. Monitoring results indicate that significant biodegradation of NDMA occurred in groundwater, accounting for an estimated 90% mass reduction over the seven-year monitoring period. In addition, a discrete effluent-discharge and groundwater-extraction event was extensively monitored in a well-characterized, localized groundwater subsystem for 626 days. Analysis of the associated NDMA fate and transport in the subsystem indicated that an estimated 80% of the recharged mass was biodegraded. The observed field evidence of NDMA biodegradation is supported by groundwater transport modeling accounting for various dilution mechanisms and first-order decay for biodegradation, and by a previous laboratory study on soil samples collected from the study site [Bradley, P.M., Carr, S.A., Baird, R.B., Chapelle, F.H., 2005. Biodegradation of N-Nitrosodimethylamine in soil from a water reclamation facility. Bioremediat. J. 9 (2), 115-120.].

  18. Challenges for Better thesis supervision.

    PubMed

    Ghadirian, Laleh; Sayarifard, Azadeh; Majdzadeh, Reza; Rajabi, Fatemeh; Yunesian, Masoud

    2014-01-01

    Conduction of thesis by the students is one of their major academic activities. Thesis quality and acquired experiences are highly dependent on the supervision. Our study is aimed at identifing the challenges in thesis supervision from both students and faculty members point of view. This study was conducted using individual in-depth interviews and Focus Group Discussions (FGD). The participants were 43 students and faculty members selected by purposive sampling. It was carried out in Tehran University of Medical Sciences in 2012. Data analysis was done concurrently with data gathering using content analysis method. Our data analysis resulted in 162 codes, 17 subcategories and 4 major categories, "supervisory knowledge and skills", "atmosphere", "bylaws and regulations relating to supervision" and "monitoring and evaluation". This study showed that more attention and planning in needed for modifying related rules and regulations, qualitative and quantitative improvement in mentorship training, research atmosphere improvement and effective monitoring and evaluation in supervisory area.

  19. Adapting a rapid assessment protocol to environmentally assess palm swamp (Veredas) springs in the Cerrado biome, Brazil.

    PubMed

    Guimarães, Ariane; de Lima Rodrigues, Aline Sueli; Malafaia, Guilherme

    2017-10-30

    The exploitation and degradation of natural environments exert intense pressure on important ecosystems worldwide. Thus, it is necessary developing or adapting assessment methods to monitor environmental changes and to generate results to be applied to environmental management programs. The Brazilian Veredas (phytophysiognomies typical to the Cerrado biome) are threatened by several human activities; thus, the aim of the present study is to adapt a rapid assessment protocol (RAP) to be applied to Veredas springs, by using the upper course of the Vai-e-Vem stream watershed (Ipameri County, Goiás State, Brazil). Therefore, several springs in the study site were visited and 11 of them were considered Veredas springs. After the RAP was adapted, the instrument was validated and used to environmentally assess the springs in order to demonstrate its applicability. The present study has provided an instrument of option to monitor Veredas springs.

  20. [Urban individual exposure to cadmium and baroreceptor response to posture].

    PubMed

    Sancini, A; Sinibaldi, F; Loreti, B; De Sio, S; Casale, T; Sacco, C; Scala, B; Monti, C; Chighine, A; Bonomi, S; Cirelli, P; Massimi, R; Giubilati, R; Tomei, F; Rosati, M V

    2014-01-01

    Outdoor workers are daily exposed to urban pollutants. The aim of the study is to evaluate the relationship between the values of environmental monitoring collected by personal dosimetries and changes in blood pressure due to posture in outdoor workers. 32 subjects of both sexes were enrolled in the study, we evaluated the values of environmental monitoring of breathable dust, nickel, arsenic, cadmium, lead, benzene, toluene, xylene and 16 PAHs. Blood pressure in supine and standing positions was measured in all subjects. The multiple linear regression analysis showed a significant reduction of orthostatic response of diastolic blood pressure in non-smoking outdoor workers occupationally exposed to cadmium. The results of our study let us to believe that exposure to low doses of urban polluted cadmium may affect the response of diastolic blood pressure to orthostatism, as per a paraphysiological condition of sympathetic down-regulation.

  1. Challenges for Better thesis supervision

    PubMed Central

    Ghadirian, Laleh; Sayarifard, Azadeh; Majdzadeh, Reza; Rajabi, Fatemeh; Yunesian, Masoud

    2014-01-01

    Background: Conduction of thesis by the students is one of their major academic activities. Thesis quality and acquired experiences are highly dependent on the supervision. Our study is aimed at identifing the challenges in thesis supervision from both students and faculty members point of view. Methods: This study was conducted using individual in-depth interviews and Focus Group Discussions (FGD). The participants were 43 students and faculty members selected by purposive sampling. It was carried out in Tehran University of Medical Sciences in 2012. Data analysis was done concurrently with data gathering using content analysis method. Results: Our data analysis resulted in 162 codes, 17 subcategories and 4 major categories, "supervisory knowledge and skills", "atmosphere", "bylaws and regulations relating to supervision" and "monitoring and evaluation". Conclusion: This study showed that more attention and planning in needed for modifying related rules and regulations, qualitative and quantitative improvement in mentorship training, research atmosphere improvement and effective monitoring and evaluation in supervisory area. PMID:25250273

  2. Detection of mesoscale convective complexes using multispectral RGB technique of Himawari-8 (Case Study: Jakarta, 20 February 2017)

    NASA Astrophysics Data System (ADS)

    Fatkhuroyan; Wati, T.

    2018-05-01

    Mesoscale Convective Complexes (MCC) is a well-organized convective cloud that has big size and long lifetime. The aim of the study is to detect and to monitor the development of MCC around Jakarta on 20th February 2017 using satellite Himawari-8. This study uses the analyzing method of the infrared channel and multispectral imagery RGB Technique to monitor the development of radiative, morphology and cloud position which describe the cloud top microphysics, structure and movement of the MCC. On 20th February 2017, the result from Himawari-8 shows that there are many dense-clouds with small ice particle and cloud top temperature could be < -50°C which can be seen as red and yellow dot colour by RGB Technique. The MCC caused a severe storm at Jakarta and its surrounding area.

  3. The Active Metabolite of Warfarin (3'-Hydroxywarfarin) and Correlation with INR, Warfarin and Drug Weekly Dosage in Patients under Oral Anticoagulant Therapy: A Pharmacogenetics Study.

    PubMed

    Gemmati, Donato; Burini, Francesco; Talarico, Anna; Fabbri, Matteo; Bertocco, Cesare; Vigliano, Marco; Moratelli, Stefano; Cuneo, Antonio; Serino, Maria Luisa; Avato, Francesco Maria; Tisato, Veronica; Gaudio, Rosa Maria

    2016-01-01

    Warfarin oral anticoagulant therapy (OAT) requires regular and frequent drug adjustment monitored by INR. Interindividual variability, drug and diet interferences, and genetics (VKORC1 and CYP2C9) make the maintenance/reaching of stable INR a not so easy task. HPLC assessment of warfarin/enantiomers was suggested as a valid monitoring-tool along with INR, but definite results are still lacking. We evaluated possible correlations between INR, warfarin/3'-hydroxywarfarin, and drug weekly dosage aimed at searching novel alternatives to OAT monitoring. VKORC1/CYP2C9 pharmacogenetics investigation was performed to account for the known influence on warfarin homeostasis. 133 OAT patients were recruited and assessed for warfarin/3'-hydroxywarfarin serum levels (HPLC), INR, and VKORC1 and CYP2C9 genotypes. A subgroup of 52 patients were monitored in detail (5 consecutive controls; c0-c4) till the target INR was reached. Correlation analyses were performed in both groups. In the whole OAT group both warfarin and 3'-hydroxywarfarin correlate with INR at comparable degree (r2 = 0.0388 and 0.0362 respectively). Conversely, warfarin weekly dosage better correlates with warfarin than with 3'-hydroxywarfarin (r2 = 0.0975 and r2 = 0.0381 respectively), but considering together warfarin plus 3'-hydroxywarfarin the correlation strongly increased (r2 = 0.1114; p<0.0001). Interestingly, 3'-hydroxywarfarin reached a strong correlation at c4 respect to warfarin (r2 = 0.2157 and r2 = 0.0549; p = 0.0005 and p = 0.0944 respectively) seeming less affected by drug adjustments in the subgroup of 52 patients who started OAT. The multivariate analyses aimed at estimating the true contribution of 3'-hydroxywarfarin on INR value ascribed it the unique significant value (p = 0.0021) in spite of warfarin who lost association. The pharmacogenetics studies confirmed that patients carrying the VKORC1 variant-allele required lower warfarin maintenance dosage and that the combination of VKORC1 and CYP2C9 yielded a warfarin responsive index (WRI) inversely related to the number variant alleles. Our results overall suggest that 3'-hydroxywarfarin monitoring could be of great advantage in INR monitoring respect to classical warfarin assessment showing significant contribution also in multivariate analysis. Therefore, additional active metabolites should be recognized and investigated as novel useful indicators.

  4. Low cost monitoring from space using Landsat TM time series and open source technologies: the case study of Iguazu park

    NASA Astrophysics Data System (ADS)

    Nole, Gabriele; Lasaponara, Rosa

    2015-04-01

    Up to nowadays, satellite data have become increasingly available, thus offering a low cost or even free of charge unique tool, with a great potential for operational monitoring of vegetation cover, quantitative assessment of urban expansion and urban sprawl, as well as for monitoring of land use changes and soil consumption. This growing observational capacity has also highlighted the need for research efforts aimed at exploring the potential offered by data processing methods and algorithms, in order to exploit as much as possible this invaluable space-based data source. The work herein presented concerns an application study on the monitoring of vegetation cover and urban sprawl conducted with the use of satellite Landsat TM data. The selected test site is the Iguazu park highly significant, being it one of the most threatened global conservation priorities (http://whc.unesco.org/en/list/303/). In order to produce synthetic maps of the investigated areas to monitor the status of vegetation and ongoing subtle changes, satellite Landsat TM data images were classified using two automatic classifiers, Maximum Likelihood (MLC) and Support Vector Machines (SVMs) applied by changing setting parameters, with the aim to compare their respective performances in terms of robustness, speed and accuracy. All process steps have been developed integrating Geographical Information System and Remote Sensing, and adopting free and open source software. Results pointed out that the SVM classifier with RBF kernel was generally the best choice (with accuracy higher than 90%) among all the configurations compared, and the use of multiple bands globally improves classification. One of the critical elements found in the case of monitoring of urban area expansion is given by the presence of urban garden mixed with urban fabric. The use of different configurations for the SVMs, i.e. different kernels and values of the setting parameters, allowed us to calibrate the classifier also to cope with a specific need, as in our case, to achieve a reliable discrimination of urban from non urban areas. Acknowledgement This research was performed within the framework of the Great relevance project " Smart management of cultural heritage sites in Italy and Argentina: Earth Observation and pilot projects funded by the Ministero degli Affari Esteri e della Cooperazione Internazionale --MAE, 17/04/2014, Prot. nr. 0090692, 2014-2016

  5. Factors controlling stream water nitrate and phosphor loads during precipitation events

    NASA Astrophysics Data System (ADS)

    Rozemeijer, J. C.; van der Velde, Y.; van Geer, F. G.; de Rooij, G. H.; Broers, H. P.; Bierkens, M. F. P.

    2009-04-01

    Pollution of surface waters in densely populated areas with intensive land use is a serious threat to their ecological, industrial and recreational utilization. European and national manure policies and several regional and local pilot projects aim at reducing pollution loads to surface waters. For the evaluation of measures, water authorities and environmental research institutes are putting a lot of effort into monitoring surface water quality. Fro regional surface water quality monitoring, the measurement locations are usually situated in the downstream part of the catchment to represent a larger area. The monitoring frequency is usually low (e.g. monthly), due to the high costs for sampling and analysis. As a consequence, human induced trends in nutrient loads and concentrations in these monitoring data are often concealed by the large variability of surface water quality caused by meteorological variations. Because natural surface water quality variability is poorly understood, large uncertainties occur in the estimates of (trends in) nutrient loads or average concentrations. This study aims at uncertainty reduction in the estimates of mean concentrations and loads of N and P from regional monitoring data. For this purpose, we related continuous N and P records of stream water to variations in precipitation, discharge, groundwater level and tube drain discharge. A specially designed multi scale experimental setup was installed in an agricultural lowland catchment in The Netherlands. At the catchment outlet, continuous measurements of water quality and discharge were performed from July 2007-January 2009. At an experimental field within the catchment continuous measurements of precipitation, groundwater levels and tube drain discharges were collected. 20 significant rainfall events with a variety of antecedent conditions, durations and intensities were selected for analysis. Singular and multiple regression analysis was used to identify relations between the continuous N and P records and characteristics of the dynamics of discharge, precipitation, groundwater level and tube drain discharge. From this study, we conclude that generally available and easy to measure explanatory data (such as continuous records of discharge, precipitation and groundwater level) can reduce uncertainty in estimations of N and P loads and mean concentrations. However, for capturing the observed short load pulses of P, continuous or discharge proportional sampling is needed.

  6. Preliminary analysis of an extensive one year survey of trace elements and compounds in the suspended particulate matter in Cleveland, Ohio

    NASA Technical Reports Server (NTRS)

    King, R. B.; Fordyce, J. S.; Antoine, A. C.; Leibecki, H. F.; Neustadter, H. E.; Sidik, S. M.; Burr, J. C.; Craig, G. T.; Cornett, C. L.

    1974-01-01

    Preliminary review of a study of trace elements and compound concentrations in the ambient suspended particulate matter in Cleveland, Ohio, measured from August 1971 through June 1973, as a function of source, monitoring location, and meteorological conditions. The study is aimed at the development of techniques for identifying specific pollution sources which could be integrated into a practical system readily usable by an enforcement agency.

  7. Smart health monitoring systems: an overview of design and modeling.

    PubMed

    Baig, Mirza Mansoor; Gholamhosseini, Hamid

    2013-04-01

    Health monitoring systems have rapidly evolved during the past two decades and have the potential to change the way health care is currently delivered. Although smart health monitoring systems automate patient monitoring tasks and, thereby improve the patient workflow management, their efficiency in clinical settings is still debatable. This paper presents a review of smart health monitoring systems and an overview of their design and modeling. Furthermore, a critical analysis of the efficiency, clinical acceptability, strategies and recommendations on improving current health monitoring systems will be presented. The main aim is to review current state of the art monitoring systems and to perform extensive and an in-depth analysis of the findings in the area of smart health monitoring systems. In order to achieve this, over fifty different monitoring systems have been selected, categorized, classified and compared. Finally, major advances in the system design level have been discussed, current issues facing health care providers, as well as the potential challenges to health monitoring field will be identified and compared to other similar systems.

  8. Individually Coded Telemetry: a Tool for Studying Heart Rate and Behaviour in Reindeer Calves

    PubMed Central

    Eloranta, E; Norberg, H; Nilsson, A; Pudas, T; Säkkinen, H

    2002-01-01

    The aim of the study was to test the performance of a silver wire modified version of the coded telemetric heart rate monitor Polar Vantage NV™ (PVNV) and to measure heart rate (HR) in a group of captive reindeer calves during different behaviour. The technical performance of PVNV HR monitors was tested in cold conditions (-30°C) using a pulse generator and the correlation between generated pulse and PVNV values was high (r = 0.9957). The accuracy was tested by comparing the HR obtained with the PVNV monitor with the standard ECG, and the correlation was significant (r = 0.9965). Both circadian HR and HR related to behavioural pattern were recorded. A circadian rhythm was observed in the HR in reindeer with a minimum during night and early morning hours and maximum at noon and during the afternoon, the average HR of the reindeer calves studied being 42.5 beats/min in February. The behaviour was recorded by focal individual observations and the data was synchronized with the output of the HR monitors. Running differed from all other behavioural categories in HR. Inter-individual differences were seen expressing individual responses to external and internal stimuli. The silver wire modified Polar Vantage NV™ provides a suitable and reliable tool for measuring heart rate in reindeer, also in natural conditions. PMID:12564543

  9. Crosslinking EEG time-frequency decomposition and fMRI in error monitoring.

    PubMed

    Hoffmann, Sven; Labrenz, Franziska; Themann, Maria; Wascher, Edmund; Beste, Christian

    2014-03-01

    Recent studies implicate a common response monitoring system, being active during erroneous and correct responses. Converging evidence from time-frequency decompositions of the response-related ERP revealed that evoked theta activity at fronto-central electrode positions differentiates correct from erroneous responses in simple tasks, but also in more complex tasks. However, up to now it is unclear how different electrophysiological parameters of error processing, especially at the level of neural oscillations are related, or predictive for BOLD signal changes reflecting error processing at a functional-neuroanatomical level. The present study aims to provide crosslinks between time domain information, time-frequency information, MRI BOLD signal and behavioral parameters in a task examining error monitoring due to mistakes in a mental rotation task. The results show that BOLD signal changes reflecting error processing on a functional-neuroanatomical level are best predicted by evoked oscillations in the theta frequency band. Although the fMRI results in this study account for an involvement of the anterior cingulate cortex, middle frontal gyrus, and the Insula in error processing, the correlation of evoked oscillations and BOLD signal was restricted to a coupling of evoked theta and anterior cingulate cortex BOLD activity. The current results indicate that although there is a distributed functional-neuroanatomical network mediating error processing, only distinct parts of this network seem to modulate electrophysiological properties of error monitoring.

  10. The Real-Time Monitoring Service Platform for Land Supervision Based on Cloud Integration

    NASA Astrophysics Data System (ADS)

    Sun, J.; Mao, M.; Xiang, H.; Wang, G.; Liang, Y.

    2018-04-01

    Remote sensing monitoring has become the important means for land and resources departments to strengthen supervision. Aiming at the problems of low monitoring frequency and poor data currency in current remote sensing monitoring, this paper researched and developed the cloud-integrated real-time monitoring service platform for land supervision which enhanced the monitoring frequency by acquiring the domestic satellite image data overall and accelerated the remote sensing image data processing efficiency by exploiting the intelligent dynamic processing technology of multi-source images. Through the pilot application in Jinan Bureau of State Land Supervision, it has been proved that the real-time monitoring technical method for land supervision is feasible. In addition, the functions of real-time monitoring and early warning are carried out on illegal land use, permanent basic farmland protection and boundary breakthrough in urban development. The application has achieved remarkable results.

  11. Health information system model for monitoring treatment and surveillance for leprosy patients in indonesia (case study in Pekalongan District, Central Java, Indonesia).

    PubMed

    Rachmani, Enny; Kurniadi, Arif; Hsu, Chien Yeh

    2013-01-01

    After India and Brazil, Indonesia has the third highest incidence/prevalence of leprosy in the world. Every year thousands of new cases and case with grade-2 disability are reported and, while the recovery rate lingers only 80-90 %. Therefore, more than 10 % of leprosy patients drop out of treatment and can be a source of new infections in the community. Our research was aimed at determining apparent difficulties in the leprosy control program as well as how a health information system (HIS) could assist the Indonesian leprosy control program. We used qualitative method with deep interview and observation of document. One of the difficulties which the Indonesian leprosy control program faces is discontinuity of patient's data due to rotating staff as well as the treatment monitoring and queries patients which should be monitored after treatment has ceased. Technology implementation is feasible through short message service (sms) reminders and web base applications. The leprosy control program urgently needs to implement continuous monitoring and recording of patients because of the particular characteristics of this contagious disease.

  12. Aggregation pheromones for monitoring the coconut rhinoceros beetle (Oryctes rhinoceros) in Jerukwangi Village, Jepara, Indonesia

    NASA Astrophysics Data System (ADS)

    Indriyanti, D. R.; Lutfiana, J. E.; Widiyaningrum, P.; Susilowati, E.; Slamet, M.

    2018-03-01

    Oryctes rhinoceros (Coleoptera: Scarabaeidae) is the most serious pest of coconut plantations in Indonesia. Jerukwangi Village is O. rhinoceros attacked one of the coconuts producing villages with more than 75% of the coconut plant population O. rhinoceros. The study aimed to monitor the population and analyze the sex ratio of O. rhinoceros that were attracted to aggregation pheromones in the field. Aggregation pheromones is a chemical compound containing Ethyl 4-methyl octanoate. The pheromone compounds were placed in traps (buckets), hung 2 meters above the ground. The traps were observed, and the beetles trapped were counted every week. In 12 weeks of monitoring, the traps captured 101 insects consist of 90.1% O. rhinoceros and 9.9% other insect species (Rhynchophorus ferrugineus and Xylotrupes gideon). This result indicates the high population of O. rhinoceros in the field. Aggregation pheromone is useful for attracting females. Rhinoceros by 61% and the males by 39%. The advantage of research is it can be used in integrated pest management (IPM) packages for monitoring of beetle population, and removal of beetles.

  13. Permanent Monitoring of the Reference Point of the 20m Radio Telescope Wettzell

    NASA Technical Reports Server (NTRS)

    Neidhardt, Alexander; Losler, Michael; Eschelbach, Cornelia; Schenk, Andreas

    2010-01-01

    To achieve the goals of the VLBI2010 project and the Global Geodetic Observing System (GGOS), an automated monitoring of the reference points of the various geodetic space techniques, including Very Long Baseline Interferometry (VLBI), is desirable. The resulting permanent monitoring of the local-tie vectors at co-location stations is essential to obtain the sub-millimeter level in the combinations. For this reason a monitoring system was installed at the Geodetic Observatory Wettzell by the Geodetic Institute of the University of Karlsruhe (GIK) to observe the 20m VLBI radio telescope from May to August 2009. A specially developed software from GIK collected data from automated total station measurements, meteorological sensors, and sensors in the telescope monument (e.g., Invar cable data). A real-time visualization directly offered a live view of the measurements during the regular observation operations. Additional scintillometer measurements allowed refraction corrections during the post-processing. This project is one of the first feasibility studies aimed at determining significant deformations of the VLBI antenna due to, for instance, changes in temperature.

  14. On the use of the EMI for the health monitoring of bonded elements

    NASA Astrophysics Data System (ADS)

    Gulizzi, Vincenzo; Rizzo, Piervincenzo; Milazzo, Alberto

    2014-03-01

    The low weight, robustness and fatigue resistance of adhesive joints make them suitable for structural joints. A fully developed nondestructive evaluation technique however is needed to monitor and assess the quality of bonded joints. In the present paper the application of the electromechanical impedance (EMI) technique is proposed. In the EMI method a piezoelectric transducer (PZT) is attached to the structure of interest. The high sensitivity and low power consumption make the EMI method feasible for real time structural health monitoring. In this study we investigated the sensitivity of the electromechanical response of a PZT to the curing and the quality of the adhesive used for bonded joints. A PXI unit running under LabView and an auxiliary circuit were employed to measure the electric impedance of a PZT glued to an aluminum plate. The system aimed at monitoring the bond line between an aluminum strip and the plate. The conductive signature of the PZT was measured and analyzed during the curing. The experimental results show that the electromechanical impedance technique is sensitive to the curing time and variations are observed for adhesives of different quality.

  15. Continuous monitoring of arthritis in animal models using optical imaging modalities

    NASA Astrophysics Data System (ADS)

    Son, Taeyoon; Yoon, Hyung-Ju; Lee, Saseong; Jang, Won Seuk; Jung, Byungjo; Kim, Wan-Uk

    2014-10-01

    Given the several difficulties associated with histology, including difficulty in continuous monitoring, this study aimed to investigate the feasibility of optical imaging modalities-cross-polarization color (CPC) imaging, erythema index (EI) imaging, and laser speckle contrast (LSC) imaging-for continuous evaluation and monitoring of arthritis in animal models. C57BL/6 mice, used for the evaluation of arthritis, were divided into three groups: arthritic mice group (AMG), positive control mice group (PCMG), and negative control mice group (NCMG). Complete Freund's adjuvant, mineral oil, and saline were injected into the footpad for AMG, PCMG, and NCMG, respectively. LSC and CPC images were acquired from 0 through 144 h after injection for all groups. EI images were calculated from CPC images. Variations in feet area, EI, and speckle index for each mice group over time were calculated for quantitative evaluation of arthritis. Histological examinations were performed, and the results were found to be consistent with those from optical imaging analysis. Thus, optical imaging modalities may be successfully applied for continuous evaluation and monitoring of arthritis in animal models.

  16. Pilot Study for Managing Complex Chronic Care Medicaid Patients With Diabetes Using a Mobile Health Application Achieves "Triple Aim" Improvement in a Primary Care Setting.

    PubMed

    Bovbjerg, Marit L; Lee, Jenney; Wolff, Rosa; Bangs, Bobby; May, Michael A

    2017-10-01

    IN BRIEF Cost-effective innovations to improve health and health care in patients with complex chronic diseases are urgently needed. Mobile health (mHealth) remote monitoring applications (apps) are a promising technology to meet this need. This article reports on a study evaluating patients' use of a tablet device with an mHealth app and a cellular-enabled glucose meter that automatically uploaded blood glucose values to the app. Improvements were observed across all three components of the Patient Protection and Affordable Care Act's "triple aim." Self-rated wellness and numerous quality-of-care metrics improved, billed charges and paid claims decreased, but no changes in clinical endpoints were observed.

  17. Multi-proxy monitoring approaches at Kangaroo Island, South Australia

    NASA Astrophysics Data System (ADS)

    Dixon, Bronwyn; Drysdale, Russell; Tyler, Jonathan; Goodwin, Ian

    2017-04-01

    Interpretations of geochemical signals preserved in young speleothems are greatly enhanced by comprehensive cave-site monitoring. In the light of this, a cave monitoring project is being conducted concurrently with the development of a new palaeoclimate record from Kelly Hill Cave (Kangaroo Island, South Australia). The site is strategically located because it is situated between longer-lived monitoring sites in southeastern and southwestern Australia, as well as being climatically 'upstream' from major population and agricultural centres. This study aims to understand possible controls on speleothem δ18O in Kelly Hill Cave through i. identification of local and regional δ18O drivers in precipitation; and ii. preservation and modification of climatic signals within the epikarst as indicated by dripwater δ18O. These aims are achieved through analysis of a five-year daily rainfall (amount and δ18O) dataset in conjunction with in-cave drip monitoring. Drivers of precipitation δ18O were identified through linear regression between δ18O values and local meteorological variables, air-parcel back trajectories, and synoptic-typing. Synoptically driven moisture sources were identified through the use of NCEP/NCAR climate reanalysis sea-level pressure, precipitable moisture, and outgoing longwave radiation data in order to trace moisture sources and travel mechanisms from surrounding ocean basins. Local controls on δ18O at Kelly Hill Cave are consistent with published interpretations of southern Australia sites, with oxygen isotopes primarily controlled by rainfall amount on both daily and monthly time scales. Back-trajectory analysis also supports previous observations that the Southern Ocean is the major source for moisture-bearing cold-front systems. However, synoptic typing of daily rainfall δ18O and amount extremes reveals a previously unreported tropical connection and moisture source. This tropical connection appears to be strongest in summer and autumn, but exists throughout the year. This indicates that a wider range of precipitation data sources can be combined to present a more comprehensive understanding of moisture dynamics and interaction of synoptic conditions to drive rainfall geochemistry. Within the cave environment at Kelly Hill Cave there is high spatial variability in drip characteristics, both in terms of drip frequency and drip water δ18O. Ongoing analyses are aimed at determining if monthly and/or seasonal rainfall δ18O drivers are also reflected in dripwater values. Overall, Kangaroo Island presents a new location to investigate the interplay between tropical and temperate influences in southern Australia, as well as a location for east - west comparisons between monitoring sites across southern Australia.

  18. Relationships Between Internal and External Match-Load Indicators in Soccer Match Officials.

    PubMed

    Castillo, Daniel; Weston, Matthew; McLaren, Shaun J; Cámara, Jesús; Yanci, Javier

    2017-08-01

    The aims of this study were to describe the internal and external match loads (ML) of refereeing activity during official soccer matches and to investigate the relationship among the methods of ML quantification across a competitive season. A further aim was to examine the usefulness of differential perceived exertion (dRPE) as a tool for monitoring internal ML in soccer referees. Twenty field referees (FRs) and 43 assistant referees (ARs) participated in the study. Data were collected from 30 competitive matches (FR = 20 observations, AR = 43 observations) and included measures of internal (Edwards' heart-rate-derived training impulse [TRIMP EDW ]) ML, external (total distance covered, distance covered at high speeds, and player load) ML, and ML differentiated ratings of perceived respiratory (sRPE res ) and leg-muscle (sRPE mus ) exertion. Internal and external ML were all greater for FRs than for ARs (-19.7 to -72.5), with differences ranging from very likely very large to most likely extremely large. The relationships between internal-ML and external-ML indicators were, in most cases, unclear for FR (r < .35) and small to moderate for AR (r < .40). The authors found substantial differences between RPE res and RPE mus scores in both FRs (0.6 AU; ±90% confidence limits 0.4 AU) and ARs (0.4; ±0.3). These data demonstrate the multifaceted demands of soccer refereeing and thereby highlight the importance of monitoring both internal and external ML. Moreover, dRPE represents distinct dimensions of effort and may be useful in monitoring soccer referees' ML during official matches.

  19. Monitoring of Plasmodium infection in humans and potential vectors of malaria in a newly emerged focus in southern Iran

    PubMed Central

    Kalantari, Mohsen; Soltani, Zahra; Ebrahimi, Mostafa; Yousefi, Masoud; Amin, Masoumeh; Shafiei, Ayda; Azizi, Kourosh

    2017-01-01

    Despite control programs, which aim to eliminate malaria from Iran by 2025, transmission of malaria has not been removed from the country. This study aimed to monitor malaria from asymptomatic parasitaemia and clinical cases from about one year of active case surveillance and potential vectors of malaria in the newly emerged focus of Mamasani and Rostam, southern Iran during 2014–2015. Samples were collected and their DNAs were extracted for Polymerase Chain Reaction (PCR) assay using specific primers for detection of Plasmodium species. The Annual Parasite Incidence rate (API) was three cases per 1,000 population from 2,000 individuals in three villages. Parasites species were detected in 9 out of the 4,000 blood smear samples among which, 6 cases were indigenous and had no history of travels to endemic areas of malaria. Also, the prevalence rate of asymptomatic parasites was about 0.3%. Overall, 1073 Anopheles spp. were caught from 9 villages. Totally, 512 female samples were checked by PCR, which indicated that none of them was infected with Plasmodium. Despite new malaria local transmission in humans in Mamasani and Rostam districts, no infection with Plasmodium was observed in Anopheles species. Because of neighboring of the studied area to the re-emerged focus in Fars province (Kazerun) and important endemic foci of malaria in other southern provinces, such as Hormozgan and Kerman, monitoring of the vectors and reservoir hosts of Plasmodium species would be unavoidable. Application of molecular methods, such as PCR, can simplify access to the highest level of accuracy in malaria researches. PMID:28078947

  20. Long- range transport of Xe-133 emissions under convective and non-convective conditions.

    NASA Astrophysics Data System (ADS)

    Kusmierczyk-Michulec, Jolanta; Gheddou, Abdelhakim

    2015-04-01

    The International Monitoring System (IMS) developed by the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) is a global system of monitoring stations, using four complementary technologies: seismic, hydroacoustic, infrasound and radionuclide. Data from all stations, belonging to IMS, are collected and transmitted to the International Data Centre (IDC) in Vienna, Austria. The radionuclide network comprises 80 stations, of which more than 60 are certified. The aim of radionuclide stations is a global monitoring of radioactive aerosols and radioactive noble gases, in particular xenon isotopes, supported by the atmospheric transport modeling (ATM). The aim of this study is to investigate the long-range transport of Xe-133 emissions under convective and non-convective conditions. For that purpose a series of 14 days forward simulations was conducted using the Lagrangian Particle Diffusion Model FLEXPART, designed for calculating the long-range and mesoscale dispersion of air pollution from point sources. The release point was at the ANSTO facility in Australia. The geographical localization to some extent justifies the assumption that the only source of Xe-133 observed at the neighbouring stations, comes from the ANSTO facility. In the simulations the analysed wind data provided by the European Centre for Medium-Range Weather Forecasts (ECMWF) were used with the spatial resolution of 0.5 degree. Studies have been performed to link Xe-133 emissions with detections at the IMS stations supported by the ATM, and to assess the impact of atmospheric convection on non-detections at the IMS stations. The results of quantitative and qualitative comparison will be presented.

  1. Remote monitoring of cardiac implantable electronic devices in Europe: results of the European Heart Rhythm Association survey.

    PubMed

    Hernández-Madrid, Antonio; Lewalter, Thorsten; Proclemer, Alessandro; Pison, Laurent; Lip, Gregory Y H; Blomstrom-Lundqvist, Carina

    2014-01-01

    The aim of this European Heart Rhythm Association survey was to provide an insight into the current use of remote monitoring for cardiac implantable electronic devices in Europe. The following topics were explored: use of remote monitoring, infrastructure and organization, patient selection and benefits. Centres using remote monitoring reported performing face-to-face visits less frequently. In many centres (56.9%), a nurse reviews all the data and forwards them to the responsible physician. The majority of the centres (91.4%) stated that remote monitoring is best used in patients with implantable cardioverter-defibrillators and those live far from the hospital (76.6% top benefit). Supraventricular and ventricular arrhythmias were reported to be the major events detected earlier by remote monitoring. Remote monitoring will have a significant impact on device management.

  2. Supporting Teachers' Well-Being in the Context of Schools for Children with Social, Emotional and Behavioural Difficulties

    ERIC Educational Resources Information Center

    Rae, Tina; Cowell, Naina; Field, Louise

    2017-01-01

    The importance of nurture for the development of well-being has been extensively documented as has the importance of the relationship between education and well-being. Supervision is seen as an invaluable and essential resource for monitoring staff well-being and as a means of maintaining effective practice. This exploratory study had two aims.…

  3. Psychometric Evaluation of a Scale to Assess Satisfaction with Life among People with Intellectual Disabilities Living in Community Residences

    ERIC Educational Resources Information Center

    Bergstrom, H.; Hochwalder, J.; Kottorp, A.; Elinder, L. S.

    2013-01-01

    Background: In the context of a health intervention among people with intellectual disabilities (ID), there was a need to assess satisfaction with some aspects of life, in order to monitor both potential positive and negative effects of the intervention. The aim of the present study was to develop and evaluate an easily administered scale for…

  4. Portugal's 2001 Drugs Liberalisation Policy: A UK Service Provider's Perspective on the Psychoactive Substances Act (2016)

    ERIC Educational Resources Information Center

    Banbury, Samantha; Lusher, Joanne; Guedelha, Francisco

    2018-01-01

    The Misuse of Drugs Act (1971) and the Psychoactive Substances Act (2016) both reinforce the criminalisation of drug use in the UK. The Psychoactive Substances Act (2016) has been developed to control and monitor the use of legal highs, particularly in institutions. This study aimed to establish drug service providers' viewpoints on how effective…

  5. FMRI Brain Activation in a Finnish Family with Specific Language Impairment Compared with a Normal Control Group

    ERIC Educational Resources Information Center

    Hugdahl, Kenneth; Gundersen, Hilde; Brekke, Cecilie; Thomsen, Tormod; Rimol, Lars Morten; Ersland, Lars; Niemi, Jussi

    2004-01-01

    The aim of the present study was to investigate differences in brain activation in a family with SLI as compared to intact individuals with normally developed language during processing of language stimuli. Functional magnetic resonance imaging (fMRI) was used to monitor changes in neuronal activation in temporal and frontal lobe areas in 5…

  6. Effect of Using Paperless Partogram on the Management and Outcome of Labour and the Nurses' Opinion

    ERIC Educational Resources Information Center

    Fatouh, Entesar; Ramadan, Sabah

    2015-01-01

    The paperless partogram refers to monitoring progress of labour and arriving at an accurate decision for intervention to ensure safe delivery. It needs no graph paper, no extra time to do it and uses the routine that the nurses are already used to. The study aimed to evaluate effect of using paperless partogram on the management and outcome of…

  7. The Differential Effects of Collaborative vs. Individual Prewriting Planning on Computer-Mediated L2 Writing: Transferability of Task-Based Linguistic Skills in Focus

    ERIC Educational Resources Information Center

    Amiryousefi, Mohammad

    2017-01-01

    The current study aimed at investigating the effects of three types of prewriting planning conditions, namely teacher-monitored collaborative planning (TMCP), student-led collaborative planning (SLCP), and individual planning (IP) on EFL learners' computer-mediated L2 written production and learning transfer from a pedagogic task to a new task of…

  8. UPLC-MS/MS method for therapeutic drug monitoring of 10 antibiotics used in intensive care units.

    PubMed

    El-Najjar, Nahed; Hösl, Julian; Holzmann, Thomas; Jantsch, Jonathan; Gessner, André

    2018-03-01

    A large variation in the levels of different ß-lactams and other antibiotics used in critically ill patients has been documented. The aim of this study is to establish and validate a fast, ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for the simultaneous analysis of ten antibiotics (Meropenem, Cefepime, Ceftazidime, Piperacillin, Benzylpenicillin, Ampicillin, Flucloxacillin, Linezolid, and Sulfamethoxazole/Trimethoprim) in human plasma according to European Medicines Agency (EMA) guidelines. Protein precipitation with ice-cold methanol containing 9 isotopically labeled internal standards was used for sample clean up. Antibiotics were detected, following a 4-minute gradient separation, in multiple reactions monitoring (MRM) using API 4000 instrument equipped with electrospray source operating in positive ion mode. The lower limit of quantification was 0.1 mg/L for Meropenem, Ceftazidime, Piperacillin, Ampicillin, Flucloxacillin, and Sulfamethoxazole; 0.05 mg/L for Cefepime, Benzylpenicillin, and Trimethoprim; and 0.02 mg/L for Linezolid. The method proved to be precise and accurate and applicable for therapeutic drug monitoring and other pharmacokinetic studies. Copyright © 2017 John Wiley & Sons, Ltd.

  9. Monitoring of pipelines in nuclear power plants by measuring laser-based mechanical impedance

    NASA Astrophysics Data System (ADS)

    Lee, Hyeonseok; Sohn, Hoon; Yang, Suyoung; Yang, Jinyeol

    2014-06-01

    Using laser-based mechanical impedance (LMI) measurement, this study proposes a damage detection technique that enables structural health monitoring of pipelines under the high temperature and radioactive environments of nuclear power plants (NPPs). The applications of conventional electromechanical impedance (EMI) based techniques to NPPs have been limited, mainly due to the contact nature of piezoelectric transducers, which cannot survive under the high temperature and high radiation environments of NPPs. The proposed LMI measurement technique aims to tackle the limitations of the EMI techniques by utilizing noncontact laser beams for both ultrasound generation and sensing. An Nd:Yag pulse laser is used for ultrasound generation, and a laser Doppler vibrometer is employed for the measurement of the corresponding ultrasound responses. For the monitoring of pipes covered by insulation layers, this study utilizes optical fibers to guide the laser beams to specific target locations. Then, an outlier analysis is adopted for autonomous damage diagnosis. Validation of the proposed LMI technique is carried out on a carbon steel pipe elbow under varying temperatures. A corrosion defect chemically engraved in the specimen is successfully detected.

  10. Acute ecotoxicity bioassay using Dendrocephalus brasiliensis: alternative test species for monitoring of contaminants in tropical and subtropical freshwaters.

    PubMed

    Santos, Vanessa Santana Vieira; Campos, Carlos Fernando; de Campos Júnior, Edimar Olegário; Pereira, Boscolli Barbosa

    2018-05-23

    In International guidelines for standard ecotoxicological bioassays, Daphnia magna is the most applied microcrustacea for assessing toxicity of different pollutants. However, in research realized in tropical and subtropical areas, autochthonous species must be prioritized because they are adapted to the specificities of ecosystems. In this sense, the present study aimed to assess and compare (with D. magna) the sensitivity of the tropical species Dendrocephalus brasiliensis as alternative test species for monitoring of contaminants in tropical and subtropical freshwaters, by carrying out acute toxicity tests with different pollutants. According results, D. brasiliensis presented EC50-48 h values lower than D. magna for all substances tested, indicating higher sensitivity of the tropical organism in relation to the temperate organism. Furthermore, comparing the results obtained with data from other studies, D. brasiliensis is more sensitive to the chemicals tested than D. magna and has similar sensitivity to Pseudosida ramosa and Ceriodaphnia dubia, common species in tropical areas. In view of this, we suggest that D. brasiliensis can be used as alternative test species for monitoring of contaminants in tropical and subtropical freshwaters.

  11. Review of Temephos Discriminating Concentration for Monitoring the Susceptibility of Anopheles labranchiae (Falleroni, 1926), Malaria Vector in Morocco

    PubMed Central

    Faraj, C.; Adlaoui, E.; Elkohli, M.; Herrak, T.; Ameur, B.; Chandre, F.

    2010-01-01

    In Morocco, the resistance monitoring of Anopheles labranchiae larvae to temephos is done using discriminating concentration of 0.125 mg, which is half of the WHO recommended dose for Anopheles. However, this dosage seemed to be too high to allow an early detection of the resistance and its revision was found necessary. The present study was carried out during May-June 2008 and 2009 in nine provinces from the north-west of the country. The aim was to determine the lethal concentrations LC100 of temephos for the most susceptible populations and to define the discriminating dosage as the double of this value. The bioassays were conducted according to WHO standard operating protocol to establish the dose-mortality relationship and deduct the LC50 and LC95. The results of this study indicated that the LC100 obtained on the most susceptible populations was close to 0.05 mg/L. Therefore, the temephos discriminating dosage for susceptibility monitoring of An. labranchiae larvae in Morocco was set to be 0.1 mg/L. PMID:22332019

  12. Plateau Waves of Intracranial Pressure and Multimodal Brain Monitoring.

    PubMed

    Dias, Celeste; Maia, Isabel; Cerejo, Antonio; Smielewski, Peter; Paiva, José-Artur; Czosnyka, Marek

    2016-01-01

    The aim of this study was to describe multimodal brain monitoring characteristics during plateau waves of intracranial pressure (ICP) in patients with head injury, using ICM+ software for continuous recording. Plateau waves consist of an abrupt elevation of ICP above 40 mmHg for 5-20 min. This is a prospective observational study of patients with head injury who were admitted to a neurocritical care unit and who developed plateau waves. We analyzed 59 plateau waves that occurred in 8 of 18 patients (44 %). At the top of plateau waves arterial blood pressure remained almost constant, but cerebral perfusion pressure, cerebral blood flow, brain tissue oxygenation, and cerebral oximetry decreased. After plateau waves, patients with a previously better autoregulation status developed hyperemia, demonstrated by an increase in cerebral blood flow and brain oxygenation. Pressure and oxygen cerebrovascular reactivity indexes (pressure reactivity index and ORxshort) increased significantly during the plateau wave as a sign of disruption of autoregulation. Bedside multimodal brain monitoring is important to characterize increases in ICP and give differential diagnoses of plateau waves, as management of this phenomenon differs from that of regular ICP.

  13. Detection of long duration cloud contamination in hyper-temporal NDVI imagery

    NASA Astrophysics Data System (ADS)

    Ali, A.; de Bie, C. A. J. M.; Skidmore, A. K.; Scarrott, R. G.

    2012-04-01

    NDVI time series imagery are commonly used as a reliable source for land use and land cover mapping and monitoring. However long duration cloud can significantly influence its precision in areas where persistent clouds prevails. Therefore quantifying errors related to cloud contamination are essential for accurate land cover mapping and monitoring. This study aims to detect long duration cloud contamination in hyper-temporal NDVI imagery based land cover mapping and monitoring. MODIS-Terra NDVI imagery (250 m; 16-day; Feb'03-Dec'09) were used after necessary pre-processing using quality flags and upper envelope filter (ASAVOGOL). Subsequently stacked MODIS-Terra NDVI image (161 layers) was classified for 10 to 100 clusters using ISODATA. After classifications, 97 clusters image was selected as best classified with the help of divergence statistics. To detect long duration cloud contamination, mean NDVI class profiles of 97 clusters image was analyzed for temporal artifacts. Results showed that long duration clouds affect the normal temporal progression of NDVI and caused anomalies. Out of total 97 clusters, 32 clusters were found with cloud contamination. Cloud contamination was found more prominent in areas where high rainfall occurs. This study can help to stop error propagation in regional land cover mapping and monitoring, caused by long duration cloud contamination.

  14. Field application of passive SBSE for the monitoring of pesticides in surface waters.

    PubMed

    Assoumani, A; Coquery, M; Liger, L; Mazzella, N; Margoum, C

    2015-03-01

    Spot sampling lacks representativeness for monitoring organic contaminants in most surface waters. Passive sampling has emerged as a cost-effective complementary sampling technique. We recently developed passive stir bar sorptive extraction (passive SBSE), with Twister from Gerstel, for monitoring moderately hydrophilic to hydrophobic pesticides (2.18 < log K ow < 5.11) in surface water. The aims of the present study were to assess this new passive sampler for the determination of representative average concentrations and to evaluate the contamination levels of two French rivers. Passive SBSE was evaluated for the monitoring of 16 pesticides in two rivers located in a small vineyard watershed during two 1-month field campaigns in spring 2010 and spring 2011. Passive SBSE was applied for periods of 1 or 2 weeks during the field campaigns and compared with spot sampling and weekly average automated sampling. The results showed that passive SBSE could achieve better time-representativeness than spot sampling and lower limits of quantification than automated sampling coupled with analytical SBSE for the pesticides studied. Finally, passive SBSE proved useful for revealing spatial and temporal variations in pesticide contamination of both rivers and the impact of rainfall and runoff on the river water quality.

  15. Social Media and Sexual Behavior Among Adolescents: Is there a link?

    PubMed Central

    2017-01-01

    Background Adolescent sexual risk taking and its consequences remain a global public health concern. Empirical evidence on the impact that social media has on sexual health behaviors among youth is sparse. Objective The study aimed to examine the relationship between social media and the change in sexual risk over time and whether parental monitoring moderates this relationship. Methods This study comprised a sample of 555 Latino youth aged 13-19 years from Maryland, United States completing baseline and follow-up surveys. Mixed-effects linear regression was used to examine the relationship between social media and the change in sexual risk over time and whether parental monitoring moderated the relationship. Results Sexual risk behaviors significantly increased between baseline (T1) and follow up (T2) (mean=0.432 vs mean=0.734, P<.001). Youth sending more than 100 text messages per day had significantly higher sexual risk scores (beta=1.008, P<.001) but significantly larger declines in sexual risk scores for higher levels of parental monitoring (beta=−.237, P=.009). Conclusions Although adolescents exchange SMS at high rates, parental monitoring remains vital to parent-child relationships and can moderate SMS frequency and sexual risk behaviors, despite parental influence diminishing and peer pressure and social influences increasing during adolescence. PMID:28526670

  16. [Nephro-urological monitoring technology based on radionuclide functional tests (tasks of an automated workplace)].

    PubMed

    Averinova, S G; Kashkadaeva, A V; Shiriaev, S V; Nechipaĭ, A M; Dmitrieva, G D

    1999-01-01

    The paper deals with a diagnostic informational and analytical system (DIAS). The system is based on the current concept of a dynamic model of nephro-urological clearance macroregulation under retention factors at the pre-, intra-, and postrenal levels during drug load tests. DIAS includes a package of dynamic renoscintigraphic techniques, as well as original software support. A system for parameters of renal clearance regulation has been developed, which is effective at nephro-urological screening and monitoring at all treatment stages for cancer patients. A two-detector chamber which permits the mounting of a detector at an angle to the patient's body is the optimum diagnostic apparatus for a cancer clinic. The use of functional tests makes it possible to examine the regulatory reserves for each kidney, followed up by the choice of adequate corrective measures to prevent renal failure during treatment. In some cases, DIAS monitoring frequently shows a higher sensitivity to the signs of latent renal failure than does routine clinical and laboratory monitoring. The effective radiation dose taken by a patient during a study by the DIAS technology aimed at reducing radioopaque doses is 100-150 times higher than that at an X-ray study and is an order less than during routine urinary tests.

  17. Why do some therapists not deal with outcome monitoring feedback? A feasibility study on the effect of regulatory focus and person-organization fit on attitude and outcome.

    PubMed

    de Jong, Kim; de Goede, Marije

    2015-01-01

    Despite research on its effectiveness, many therapists still have negative attitudes toward using outcome monitoring feedback. The current study aims to investigate how the perceived match between values of an individual and those of the organization (Person-Organization fit; PO fit), and motivation to prevent failure or to achieve success (regulatory focus) are related to therapists' attitude, attitude changes over time, and outcomes. Therapists (n = 20) filled out a feedback attitude questionnaire at two points in time: before the start of outcome monitoring, and after six months. In addition, they completed measures on PO fit and regulatory focus. PO fit was predictive of outcomes, when feedback was provided, but did not predict therapists' attitude. Therapists with a strong prevention focus (prevent failures), had a more positive attitude toward feedback, but achieved slower symptom reduction in their at risk cases. A strong promotion focus (achieve success) was not predictive of attitude, but did result in faster symptom reduction in at risk patients when feedback was provided. Therapists motivational approach to work and the perceived match with the organization they work for, can influence both their attitude toward outcome monitoring and their outcomes.

  18. Use of Time-Resolved Fluorescence to Monitor Bioactive Compounds in Plant Based Foodstuffs

    PubMed Central

    Lemos, M. Adília; Sárniková, Katarína; Bot, Francesca; Anese, Monica; Hungerford, Graham

    2015-01-01

    The study of compounds that exhibit antioxidant activity has recently received much interest in the food industry because of their potential health benefits. Most of these compounds are plant based, such as polyphenolics and carotenoids, and there is a need to monitor them from the field through processing and into the body. Ideally, a monitoring technique should be non-invasive with the potential for remote capabilities. The application of the phenomenon of fluorescence has proved to be well suited, as many plant associated compounds exhibit fluorescence. The photophysical behaviour of fluorescent molecules is also highly dependent on their microenvironment, making them suitable probes to monitor changes in pH, viscosity and polarity, for example. Time-resolved fluorescence techniques have recently come to the fore, as they offer the ability to obtain more information, coupled with the fact that the fluorescence lifetime is an absolute measure, while steady state just provides relative and average information. In this work, we will present illustrative time-resolved measurements, rather than a comprehensive review, to show the potential of time-resolved fluorescence applied to the study of bioactive substances. The aim is to help assess if any changes occur in their form, going from extraction via storage and cooking to the interaction with serum albumin, a principal blood transport protein. PMID:26132136

  19. Emerging ecological datasets with application for modeling North American dust emissions

    NASA Astrophysics Data System (ADS)

    McCord, S.; Stauffer, N. G.; Garman, S.; Webb, N.

    2017-12-01

    In 2011 the US Bureau of Land Management (BLM) established the Assessment, Inventory and Monitoring (AIM) program to monitor the condition of BLM land and to provide data to support evidence-based management of multi-use public lands. The monitoring program shares core data collection methods with the Natural Resources Conservation Service's (NRCS) National Resources Inventory (NRI), implemented on private lands nationally. Combined, the two programs have sampled >30,000 locations since 2003 to provide vegetation composition, vegetation canopy height, the size distribution of inter-canopy gaps, soil texture and crusting information on rangelands and pasture lands across North America. The BLM implements AIM on more than 247.3 million acres of land across the western US, encompassing major dust source regions of the Chihuahuan, Sonoran, Mojave and Great Basin deserts, the Colorado Plateau, and potential high-latitude dust sources in Alaska. The AIM data are publicly available and can be used to support modeling of land surface and boundary-layer processes, including dust emission. While understanding US dust source regions and emission processes has been of national interest since the 1930s Dust Bowl, most attention has been directed to the croplands of the Great Plains and emission hot spots like Owens Lake, California. The magnitude, spatial extent and temporal dynamics of dust emissions from western dust source areas remain highly uncertain. Here, we use ensemble modeling with empirical and physically-based dust emission schemes applied to AIM monitoring data to assess regional-scale patterns of aeolian sediment mass fluxes and dust emissions. The analysis enables connections to be made between dust emission rates at source and other indicators of ecosystem function at the landscape scale. Emerging ecological datasets like AIM provide new opportunities to evaluate aeolian sediment transport responses to land surface conditions, potential interactions with disturbances (e.g., fire) and ecological change (e.g., invasive species), and the impacts of anthropogenic land use and land cover change.

  20. Combined intracranial pressure monitoring and cerebrospinal fluid infusion study to guide management of slit ventricle syndrome.

    PubMed

    Hart, Michael Gavin; Czosnyka, Marek; Czosnyka, Zofia Helena; Fernandes, Helen Marie

    2013-01-01

    Slit ventricle syndrome remains a complex entity presenting a considerable challenge to treat successfully. This study aims to demonstrate the application of dual intracranial pressure (ICP) and infusion studies together with the novel shunt occlusion test in both a diagnostic and therapeutic role. An 8-year-old child had aqueduct stenosis treated with a ventriculoperitoneal shunt (medium-pressure valve). The presentation was of headaches with papilloedema. Imaging with both computed tomography and magnetic resonance imaging revealed slit ventricles. Initially a shunt exploration revealed distal obstruction that was treated together with insertion of a paediatric strata II regular valve; however, the child continued to deteriorate. Overnight ICP monitoring revealed dramatically raised ICP with poor compensatory reserve. Intra-operative infusion study revealed a shunt that was patent distally but with proximal obstruction. A subtemporal decompression ipsilateral to the shunt was performed together with adjustment of the paediatric strata II regular valve to 2.5 in order to prevent overdrainage. This led to normalisation of ICP, resolution of papilloedema and symptomatic improvement. We demonstrate how combined ICP monitoring and shunt infusion studies can be used to help guide management. Unilateral subtemporal decompressions and preventing shunt overdrainage can result in normalisation of ICP and cerebrospinal fluid dynamics.

Top