Sample records for monitoring system cems

  1. Field evaluation of Fourier transform infrared continuous emissions monitoring (FTIR CEM) systems

    NASA Astrophysics Data System (ADS)

    Dunder, Thomas A.; Geyer, Thomas J.; Kinner, Laura L.; Plummer, Grant M.

    1995-02-01

    Recent environmental regulations, including the Clean Air Act and the Enhanced Monitoring Regulations, may require continuous emissions monitoring (CEM) of hazardous air pollutants (HAPs). A promising technique for this application is Fourier transform infrared spectroscopy (FTIR). FTIR spectroscopy can, in principle, be used to monitor virtually any gas phase species. Two evaluations of FTIR CEM systems are discussed. The first study, performed in 1993 - 94, compared two FTIR CEM systems on a side-by-side basis in an extended field test at two coal-fired electric power plants. The FTIR CEM systems monitored the legally mandated criteria pollutants and diluents (CO, CO2, NO, NO2, and SO2) as well as H2O. In addition, one system monitored two HAPs (HCl and HF) and NH3. The FTIR CEM measurements were compared with those from the compliance CEM systems at the facilities. Several relative accuracy test audits were also performed to verify the FTIR CEM accuracy. The second evaluation was recently commenced on behalf of the Environmental Protection Agency. In this study, FTIR CEM systems are evaluated specifically for the monitoring of HAP species by conducting laboratory and field tests. The evaluation culminates in the development of proposed performance specifications and protocols for FTIR CEM systems.

  2. 40 CFR Table 3 of Subpart Aaaa to... - Requirements for Validating Continuous Emission Monitoring Systems (CEMS)

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Requirements for Validating Continuous Emission Monitoring Systems (CEMS) 3 Table 3 of Subpart AAAA to Part 60 Protection of Environment... Continuous Emission Monitoring Systems (CEMS) For the following continuous emission monitoring systems Use...

  3. 40 CFR Table 3 of Subpart Aaaa to... - Requirements for Validating Continuous Emission Monitoring Systems (CEMS)

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Requirements for Validating Continuous Emission Monitoring Systems (CEMS) 3 Table 3 of Subpart AAAA to Part 60 Protection of Environment... Continuous Emission Monitoring Systems (CEMS) For the following continuous emission monitoring systems Use...

  4. 40 CFR Table 6 to Subpart Bbbb of... - Model Rule-Requirements for Validating Continuous Emission Monitoring Systems (CEMS)

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Continuous Emission Monitoring Systems (CEMS) 6 Table 6 to Subpart BBBB of Part 60 Protection of Environment...—Requirements for Validating Continuous Emission Monitoring Systems (CEMS) For the following continuous emission monitoring systems Use the following methods in appendix A of this part to validate poollutant concentratin...

  5. 40 CFR Table 6 to Subpart Bbbb of... - Model Rule-Requirements for Validating Continuous Emission Monitoring Systems (CEMS)

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Continuous Emission Monitoring Systems (CEMS) 6 Table 6 to Subpart BBBB of Part 60 Protection of Environment...—Requirements for Validating Continuous Emission Monitoring Systems (CEMS) For the following continuous emission monitoring systems Use the following methods in appendix A of this part to validate poollutant concentratin...

  6. 40 CFR Table 7 to Subpart Jjj of... - Requirements for Continuous Emission Monitoring Systems (CEMS) a

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 8 2011-07-01 2011-07-01 false Requirements for Continuous Emission Monitoring Systems (CEMS) a 7 Table 7 to Subpart JJJ of Part 62 Protection of Environment ENVIRONMENTAL...—Requirements for Continuous Emission Monitoring Systems (CEMS) a ER31JA03.013 ...

  7. 40 CFR Table 7 to Subpart Jjj of... - Requirements for Continuous Emission Monitoring Systems (CEMS) a

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Requirements for Continuous Emission Monitoring Systems (CEMS) a 7 Table 7 to Subpart JJJ of Part 62 Protection of Environment ENVIRONMENTAL...—Requirements for Continuous Emission Monitoring Systems (CEMS) a ER31JA03.013 ...

  8. 40 CFR Table 3 to Subpart Eeee of... - Requirements for Continuous Emission Monitoring Systems (CEMS)

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Monitoring Systems (CEMS) 3 Table 3 to Subpart EEEE of Part 60 Protection of Environment ENVIRONMENTAL..., Subpt. EEEE, Table 3 Table 3 to Subpart EEEE of Part 60—Requirements for Continuous Emission Monitoring Systems (CEMS) As stated in § 60.2940, you must comply with the following: For the followingpollutants Use...

  9. 40 CFR Table 6 to Subpart Jjj of... - Requirements for Validating Continuous Emission Monitoring Systems (CEMS)

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 8 2011-07-01 2011-07-01 false Requirements for Validating Continuous Emission Monitoring Systems (CEMS) 6 Table 6 to Subpart JJJ of Part 62 Protection of Environment... of Part 62—Requirements for Validating Continuous Emission Monitoring Systems (CEMS) ER31JA03.012 ...

  10. 40 CFR Table 4 to Subpart Ffff of... - Model Rule-Requirements for Continuous Emission Monitoring Systems (CEMS)

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Model Rule-Requirements for Continuous Emission Monitoring Systems (CEMS) 4 Table 4 to Subpart FFFF of Part 60 Protection of Environment...—Model Rule—Requirements for Continuous Emission Monitoring Systems (CEMS) As stated in § 60.3039, you...

  11. 40 CFR Table 4 to Subpart Ffff of... - Model Rule-Requirements for Continuous Emission Monitoring Systems (CEMS)

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Model Rule-Requirements for Continuous Emission Monitoring Systems (CEMS) 4 Table 4 to Subpart FFFF of Part 60 Protection of Environment...—Model Rule—Requirements for Continuous Emission Monitoring Systems (CEMS) As stated in § 60.3039, you...

  12. 40 CFR Table 3 to Subpart Eeee of... - Requirements for Continuous Emission Monitoring Systems (CEMS)

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Monitoring Systems (CEMS) 3 Table 3 to Subpart EEEE of Part 60 Protection of Environment ENVIRONMENTAL..., Subpt. EEEE, Table 3 Table 3 to Subpart EEEE of Part 60—Requirements for Continuous Emission Monitoring Systems (CEMS) As stated in § 60.2940, you must comply with the following: For the followingpollutants Use...

  13. 40 CFR Table 6 to Subpart Jjj of... - Requirements for Validating Continuous Emission Monitoring Systems (CEMS)

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Requirements for Validating Continuous Emission Monitoring Systems (CEMS) 6 Table 6 to Subpart JJJ of Part 62 Protection of Environment... of Part 62—Requirements for Validating Continuous Emission Monitoring Systems (CEMS) ER31JA03.012 ...

  14. 40 CFR Table 7 to Subpart Bbbb of... - Model Rule-Requirements for Continuous Emission Monitoring Systems (CEMS)

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...—Requirements for Continuous Emission Monitoring Systems (CEMS) For the following pollutants Use the following span values for CEMS Use the following performance specifications in appendix B of this part for your CEMS If needed to meet minimum data requirements, use the folloiwng alternate methods in appendix A of...

  15. 40 CFR Table 7 to Subpart Bbbb of... - Model Rule-Requirements for Continuous Emission Monitoring Systems (CEMS)

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...—Requirements for Continuous Emission Monitoring Systems (CEMS) For the following pollutants Use the following span values for CEMS Use the following performance specifications in appendix B of this part for your CEMS If needed to meet minimum data requirements, use the folloiwng alternate methods in appendix A of...

  16. 40 CFR Table 4 to Subpart Ffff of... - Model Rule-Requirements for Continuous Emission Monitoring Systems (CEMS)

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Emission Monitoring Systems (CEMS) 4 Table 4 to Subpart FFFF of Part 60 Protection of Environment... Construction On or Before December 9, 2004 Pt. 60, Subpt. FFFF, Table 4 Table 4 to Subpart FFFF of Part 60—Model Rule—Requirements for Continuous Emission Monitoring Systems (CEMS) As stated in § 60.3039, you...

  17. 40 CFR Table 4 to Subpart Ffff of... - Model Rule-Requirements for Continuous Emission Monitoring Systems (CEMS)

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Emission Monitoring Systems (CEMS) 4 Table 4 to Subpart FFFF of Part 60 Protection of Environment... Construction On or Before December 9, 2004 Pt. 60, Subpt. FFFF, Table 4 Table 4 to Subpart FFFF of Part 60—Model Rule—Requirements for Continuous Emission Monitoring Systems (CEMS) As stated in § 60.3039, you...

  18. 40 CFR Table 4 to Subpart Ffff of... - Model Rule-Requirements for Continuous Emission Monitoring Systems (CEMS)

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Emission Monitoring Systems (CEMS) 4 Table 4 to Subpart FFFF of Part 60 Protection of Environment... Construction On or Before December 9, 2004 Pt. 60, Subpt. FFFF, Table 4 Table 4 to Subpart FFFF of Part 60—Model Rule—Requirements for Continuous Emission Monitoring Systems (CEMS) As stated in § 60.3039, you...

  19. How to select a continuous emission monitoring system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Radigan, M.J.

    1994-02-01

    Selecting a continuous emission monitoring system (CEMS) involves more than picking an analyzer. Successful CEMS interface sampling and data-management systems to produce accurate, reliable reports required by regulatory agencies. Following objective guidelines removes some of the misery from CEMS shopping. However, prospective CEMS buyers should do their homework and develop well-thought-out, detailed specification for the processes' sampling criteria. Fine tuning the analyzer/data management system can eliminate maintenance costs and keep the facility operating within its permit restrictions.

  20. 40 CFR Table 4 of Subpart Aaaa to... - Requirements for Continuous Emission Monitoring Systems (CEMS)

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Monitoring Systems (CEMS) For the following pollutants Use the following span values for your CEMS Use the... requirements, use the following alternate methods in appendix A of this part to collect data 1. Opacity 100... unit P.S. 2 Method 6C. 4. Carbon Monoxide 125 percent of the maximum expected hourly potential carbon...

  1. 40 CFR Table 4 of Subpart Aaaa to... - Requirements for Continuous Emission Monitoring Systems (CEMS)

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Monitoring Systems (CEMS) For the following pollutants Use the following span values for your CEMS Use the... requirements, use the following alternate methods in appendix A of this part to collect data 1. Opacity 100... unit P.S. 2 Method 6C. 4. Carbon Monoxide 125 percent of the maximum expected hourly potential carbon...

  2. AN ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) TESTING OF FOUR MERCURY EMISSION SAMPLING SYSTEMS

    EPA Science Inventory

    CEMs - Tekran Instrument Corp. Series 3300 and Thermo Electron's Mercury Freedom System Continuous Emission Monitors (CEMs) for mercury are designed to determine total and/or chemically speciated vapor-phase mercury in combustion emissions. Performance for mercury CEMs are cont...

  3. 40 CFR Table 3 to Subpart Eeee of... - Requirements for Continuous Emission Monitoring Systems (CEMS)

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Monitoring Systems (CEMS) 3 Table 3 to Subpart EEEE of Part 60 Protection of Environment ENVIRONMENTAL... December 9, 2004, or for Which Modification or Reconstruction is Commenced on or After June 16, 2006 Pt. 60, Subpt. EEEE, Table 3 Table 3 to Subpart EEEE of Part 60—Requirements for Continuous Emission Monitoring...

  4. 40 CFR Table 3 to Subpart Eeee of... - Requirements for Continuous Emission Monitoring Systems (CEMS)

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Monitoring Systems (CEMS) 3 Table 3 to Subpart EEEE of Part 60 Protection of Environment ENVIRONMENTAL... December 9, 2004, or for Which Modification or Reconstruction is Commenced on or After June 16, 2006 Pt. 60, Subpt. EEEE, Table 3 Table 3 to Subpart EEEE of Part 60—Requirements for Continuous Emission Monitoring...

  5. 40 CFR Table 3 to Subpart Eeee of... - Requirements for Continuous Emission Monitoring Systems (CEMS)

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Monitoring Systems (CEMS) 3 Table 3 to Subpart EEEE of Part 60 Protection of Environment ENVIRONMENTAL... December 9, 2004, or for Which Modification or Reconstruction is Commenced on or After June 16, 2006 Pt. 60, Subpt. EEEE, Table 3 Table 3 to Subpart EEEE of Part 60—Requirements for Continuous Emission Monitoring...

  6. 40 CFR Table 7 to Subpart Bbbb of... - Model Rule-Requirements for Continuous Emission Monitoring Systems (CEMS)

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Emission Monitoring Systems (CEMS) 7 Table 7 to Subpart BBBB of Part 60 Protection of Environment... or Before August 30, 1999 Pt. 60, Subpt. BBBB, Table 7 Table 7 to Subpart BBBB of Part 60—Model Rule... sulfur dioxide emissions of the municipal waste combustion unit 4. Carbon Monoxide 125 percent of the...

  7. 40 CFR Table 4 of Subpart Aaaa to... - Requirements for Continuous Emission Monitoring Systems (CEMS)

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Monitoring Systems (CEMS) 4 Table 4 of Subpart AAAA to Part 60 Protection of Environment ENVIRONMENTAL.... 60, Subpt. AAAA, Table 4 Table 4 of Subpart AAAA to Part 60—Requirements for Continuous Emission... unit P.S. 2 Method 6C. 4. Carbon Monoxide 125 percent of the maximum expected hourly potential carbon...

  8. 40 CFR Table 3 of Subpart Aaaa of... - Requirements for Validating Continuous Emission Monitoring Systems (CEMS)

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Emission Monitoring Systems (CEMS) 3 Table 3 of Subpart AAAA of Part 60 Protection of Environment... Definitions What definitions must I know? Pt. 60, Subpt. AAAA, Table 3 Table 3 of Subpart AAAA of Part 60... levels Use the following methods in appendix A of this part to measure oxygen (or carbon dioxide) 1...

  9. 40 CFR Table 4 of Subpart Aaaa of... - Requirements for Continuous Emission Monitoring Systems (CEMS)

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Monitoring Systems (CEMS) 4 Table 4 of Subpart AAAA of Part 60 Protection of Environment ENVIRONMENTAL... Definitions What definitions must I know? Pt. 60, Subpt. AAAA, Table 4 Table 4 of Subpart AAAA of Part 60... dioxide emissions of the municipal waste combustion unit P.S. 2 Method 6C. 4. Carbon Monoxide 125 percent...

  10. 40 CFR Table 4 of Subpart Aaaa of... - Requirements for Continuous Emission Monitoring Systems (CEMS)

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Monitoring Systems (CEMS) 4 Table 4 of Subpart AAAA of Part 60 Protection of Environment ENVIRONMENTAL... Definitions What definitions must I know? Pt. 60, Subpt. AAAA, Table 4 Table 4 of Subpart AAAA of Part 60... dioxide emissions of the municipal waste combustion unit P.S. 2 Method 6C. 4. Carbon Monoxide 125 percent...

  11. 40 CFR Table 7 to Subpart Bbbb of... - Model Rule-Requirements for Continuous Emission Monitoring Systems (CEMS)

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Emission Monitoring Systems (CEMS) 7 Table 7 to Subpart BBBB of Part 60 Protection of Environment... or Before August 30, 1999 Pt. 60, Subpt. BBBB, Table 7 Table 7 to Subpart BBBB of Part 60—Model Rule... sulfur dioxide emissions of the municipal waste combustion unit 4. Carbon Monoxide 125 percent of the...

  12. 40 CFR Table 3 of Subpart Aaaa to... - Requirements for Validating Continuous Emission Monitoring Systems (CEMS)

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Emission Monitoring Systems (CEMS) 3 Table 3 of Subpart AAAA to Part 60 Protection of Environment... SOURCES Pt. 60, Subpt. AAAA, Table 3 Table 3 of Subpart AAAA to Part 60—Requirements for Validating... following methods in appendix A of this part to measure oxygen (or carbon dioxide) 1. Nitrogen Oxides (Class...

  13. 40 CFR Table 7 to Subpart Bbbb of... - Model Rule-Requirements for Continuous Emission Monitoring Systems (CEMS)

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Emission Monitoring Systems (CEMS) 7 Table 7 to Subpart BBBB of Part 60 Protection of Environment... or Before August 30, 1999 Pt. 60, Subpt. BBBB, Table 7 Table 7 to Subpart BBBB of Part 60—Model Rule... sulfur dioxide emissions of the municipal waste combustion unit 4. Carbon Monoxide 125 percent of the...

  14. 40 CFR 63.9307 - What are my continuous emissions monitoring system installation, operation, and maintenance...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... install, operate, and maintain each CEMS to monitor carbon monoxide (CO) or total hydrocarbons (THC) and... emission control device. (b) To comply with the CO or THC percent reduction emission limitation, you may install, operate, and maintain a CEMS to monitor CO or THC and O2 at both the inlet and the outlet of the...

  15. 40 CFR 63.9307 - What are my continuous emissions monitoring system installation, operation, and maintenance...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... install, operate, and maintain each CEMS to monitor carbon monoxide (CO) or total hydrocarbons (THC) and... emission control device. (b) To comply with the CO or THC percent reduction emission limitation, you may install, operate, and maintain a CEMS to monitor CO or THC and O2 at both the inlet and the outlet of the...

  16. 40 CFR 63.9307 - What are my continuous emissions monitoring system installation, operation, and maintenance...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... install, operate, and maintain each CEMS to monitor carbon monoxide (CO) or total hydrocarbons (THC) and... emission control device. (b) To comply with the CO or THC percent reduction emission limitation, you may install, operate, and maintain a CEMS to monitor CO or THC and O2 at both the inlet and the outlet of the...

  17. 40 CFR 63.9307 - What are my continuous emissions monitoring system installation, operation, and maintenance...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... install, operate, and maintain each CEMS to monitor carbon monoxide (CO) or total hydrocarbons (THC) and... emission control device. (b) To comply with the CO or THC percent reduction emission limitation, you may install, operate, and maintain a CEMS to monitor CO or THC and O2 at both the inlet and the outlet of the...

  18. 40 CFR 63.9307 - What are my continuous emissions monitoring system installation, operation, and maintenance...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... install, operate, and maintain each CEMS to monitor carbon monoxide (CO) or total hydrocarbons (THC) and... emission control device. (b) To comply with the CO or THC percent reduction emission limitation, you may install, operate, and maintain a CEMS to monitor CO or THC and O2 at both the inlet and the outlet of the...

  19. 40 CFR Table 6 to Subpart Bbbb of... - Model Rule-Requirements for Validating Continuous Emission Monitoring Systems (CEMS)

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Continuous Emission Monitoring Systems (CEMS) 6 Table 6 to Subpart BBBB of Part 60 Protection of Environment... or Before August 30, 1999 Pt. 60, Subpt. BBBB, Table 6 Table 6 to Subpart BBBB of Part 60—Model Rule... levels Use the following methods in appendix A of this part to measure oxygen (or carbon dioxide) 1...

  20. 40 CFR Table 6 to Subpart Bbbb of... - Model Rule-Requirements for Validating Continuous Emission Monitoring Systems (CEMS)

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Continuous Emission Monitoring Systems (CEMS) 6 Table 6 to Subpart BBBB of Part 60 Protection of Environment... or Before August 30, 1999 Pt. 60, Subpt. BBBB, Table 6 Table 6 to Subpart BBBB of Part 60—Model Rule... levels Use the following methods in appendix A of this part to measure oxygen (or carbon dioxide) 1...

  1. 40 CFR Table 2 to Subpart Hhhh of... - Applicability of General Provisions (40 CFR Part 63, Subpart A) to Subpart HHHH

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Alternative Test Method Yes EPA retains approval authority § 63.7(g) Data Analysis Yes § 63.7(h) Waiver of... monitoring systems (CEMS) § 63.8(g)(1) Data Reduction Yes § 63.8(g)(2) Data Reduction No Subpart HHHH does not require the use of CEMS or continuous opacity monitoring systems (COMS). § 63.8(g)(3)-(5) Data...

  2. 40 CFR 60.2710 - How do I demonstrate continuous compliance with the emission limitations and the operating limits?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... performance test deadline for PM CEMS. Relative accuracy testing for other CEMS need not be repeated if that... system. (i) Installation of the continuous monitoring system sampling probe or other interface at a... equipment specifications for the sample interface, the pollutant concentration or parametric signal analyzer...

  3. Continuous ECG monitoring for tracking down atrial fibrillation after stroke: Holter or automated analysis strategy?

    PubMed

    Suissa, Laurent; Lachaud, Sylvain; Mahagne, Marie-Hélène

    2014-01-01

    Tracking down atrial fibrillation (AF) in the stroke unit is a relevant challenge for the prevention of recurrent AF-related stroke. The optimal terms of use of continuous ECG monitoring (CEM) are unknown. We compared 24-hour routine Holter ECG with two different CEM analysis strategies for AF detection. We prospectively enrolled consecutive ischemic stroke patients. All AF-naïve patients received CEM during hospitalization. Two methods for reading CEM data were compared: manual analysis using the Holter function (hCEM) and semiautomated analysis using software (aCEM). The McNemar test was used to compare AF detection rates. Of the 362 patients included, 58 (16.0%) were non-AF-naïve patients and 304 were AF-naïve patients. AF-Naïve patients underwent CEM with a median duration of 5.3 days (3.4-9.7). We detected 22 new AF cases (7.2%) with first-24-hour hCEM, 31 (10.2%) with aCEM, and 42 (13.8%) with hCEM. hCEM and aCEM both significantly increased the AF detection rate compared to first-24-hour hCEM. hCEM detected more new AF cases than aCEM (+3.6%, p = 0.003). In stroke patients, early and prolonged aCEM and hCEM both increase the AF detection rate compared to first-24-hour hCEM. hCEM gives the best AF detection rate. We suggest that in aCEM, detection based only on the ventricular rhythm analysis explains its lower specificity and sensitivity. © 2014 S. Karger AG, Basel.

  4. Field testing of particulate matter continuous emission monitors at the DOE Oak Ridge TSCA incinerator. Toxic Substances Control Act.

    PubMed

    Dunn, James E; Davis, Wayne T; Calcagno, James A; Allen, Marshall W

    2002-01-01

    A field study to evaluate the performance of three commercially available particulate matter (PM) continuous emission monitors (CEMs) was conducted in 1999-2000 at the US Department of Energy (DOE) Toxic Substances Control Act (TSCA) Incinerator. This study offers unique features that are believed to enhance the collective US experience with PM CEMs. The TSCA Incinerator is permitted to treat PCB-contaminated RCRA hazardous low-level radioactive wastes. The air pollution control system utilizes MACT control technology and is comprised of a rapid quench, venturi scrubber, packed bed scrubber, and two ionizing wet scrubbers in series, which create a saturated flue gas that must be conditioned by the CEMs prior to measurement. The incinerator routinely treats a wide variety of wastes including high and low BTU organic liquids, aqueous, and solid wastes. The various possible combinations for treating liquid and solid wastes may present a challenge in establishing a single, acceptable correlation relationship for individual CEMs. The effect of low-level radioactive material present in the waste is a unique site-specific factor not evaluated in previous tests. The three systems chosen for evaluation were two beta gauge devices and a light scattering device. The performance of the CEMs was evaluated using the requirements in draft Environmental Protection Agency (EPA) Performance Specification 11 (PS11) and Procedure 2. The results of Reference Method 5i stack tests for establishing statistical correlations between the reference method data and the CEMs responses are discussed.

  5. A feasibility study on the predictive emission monitoring system applied to the Hsinta power plant of Taiwan Power Company.

    PubMed

    Chien, T W; Chu, H; Hsu, W C; Tseng, T K; Hsu, C H; Chen, K Y

    2003-08-01

    The continuous emission monitoring system (CEMS) can monitor flue gas emissions continuously and instantaneously. However, it has the disadvantages of enormous cost, easily producing errors in sampling periods of bad weather, lagging response in variable ambient environments, and missing data in daily zero and span tests and maintenance. The concept of a predictive emission monitoring system (PEMS) is to use the operating parameters of combustion equipment through thermodynamic or statistical methods to construct a mathematic model that can predict emissions by a computer program. The goal of this study is to set up a PEMS in a gas-fired combined cycle power generation unit at the Hsinta station of Taiwan Power Co. The emissions to be monitored include nitrogen oxides (NOx) and oxygen (O2) in flue gas. The major variables of the predictive model were determined based on the combustion theory. The data of these variables then were analyzed to establish a regression model. From the regression results, the influences of these variables are discussed and the predicted values are compared with the CEMS data for accuracy. In addition, according to the cost information, the capital and operation and maintenance costs for a PEMS can be much lower than those for a CEMS.

  6. 40 CFR Table 1 to Subpart Lll of... - Applicability of General Provisions

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... requirements for THC CEMS Temperature and activated carbon injection monitoring data reduction requirements... specification supersedes requirements for THC CEMS. 63.8(f)(1)-(5) Alternative Monitoring Method Yes Additional... requirements for THC CEMS. 63.10(c)(2)-(4) No [Reserved] 63.10(c)(5)-(8) Additional CMS Recordkeeping Yes PS-8A...

  7. Eliminating Bias

    EPA Pesticide Factsheets

    Learn how to eliminate bias from monitoring systems by instituting appropriate installation, operation, and quality assurance procedures. Provides links to download An Operator's Guide to Eliminating Bias in CEM Systems.

  8. Predictive NO x emission monitoring on board a passenger ferry

    NASA Astrophysics Data System (ADS)

    Cooper, D. A.; Andreasson, K.

    NO x emissions from a medium speed diesel engine on board a servicing passenger ferry have been indirectly measured using a predictive emission monitoring system (PEMS) over a 1-yr period. Conventional NO x measurements were carried out with a continuous emission monitoring system (CEMS) at the start of the study to provide historical data for the empirical PEMS function. On three other occasions during the year the CEMS was also used to verify the PEMS and follow any changes in emission signature of the engine. The PEMS consisted of monitoring exhaust O 2 concentrations (in situ electrochemical probe), engine load, combustion air temperature and humidity, and barometric pressure. Practical experiences with the PEMS equipment were positive and measurement data were transferred to a land-based office by using a modem data communication system. The initial PEMS function (PEMS1) gave systematic differences of 1.1-6.9% of the calibration domain (0-1725 ppm) and a relative accuracy of 6.7% when compared with CEMS for whole journeys and varying load situations. Further improvements on the performance could be obtained by updating this function. The calculated yearly emission for a total engine running time of 4618 h was 316 t NO x±38 t and the average NO x emission corrected for ambient conditions 14.3 g kWh corr-1. The exhaust profile of the engine in terms of NO x, CO and CO 2 emissions as determined by CEMS was similar for most of the year. Towards the end of the study period, a significantly lower NO x emission was detected which was probably caused by replacement of fuel injector nozzles. The study suggests that PEMS can be a viable option for continuous, long-term NO x measurements on board ships.

  9. 40 CFR 97.71 - Initial certification and recertification procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Monitoring and Reporting § 97.71 Initial certification and recertification procedures. (a) The owner or... monitors, NOX concentration CEMS, or excepted monitoring systems under appendix E of part 75 of this... operator of such a unit that qualifies to use the low mass emissions excepted monitoring methodology under...

  10. 40 CFR 97.71 - Initial certification and recertification procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Monitoring and Reporting § 97.71 Initial certification and recertification procedures. (a) The owner or... monitors, NOX concentration CEMS, or excepted monitoring systems under appendix E of part 75 of this... operator of such a unit that qualifies to use the low mass emissions excepted monitoring methodology under...

  11. MERCURY CEMS: TECHNOLOGY UPDATE

    EPA Science Inventory

    The paper reviews the technologies involved with continuous emission monitors (CEMs) for mercury (Hg) which are receiving incresed attention and focus. Their potential use as a compliance assurance tool is of particular interest. While Hg CEMs are currently used in Europe for com...

  12. CEM43°C thermal dose thresholds: a potential guide for magnetic resonance radiofrequency exposure levels?

    PubMed

    van Rhoon, Gerard C; Samaras, Theodoros; Yarmolenko, Pavel S; Dewhirst, Mark W; Neufeld, Esra; Kuster, Niels

    2013-08-01

    To define thresholds of safe local temperature increases for MR equipment that exposes patients to radiofrequency fields of high intensities for long duration. These MR systems induce heterogeneous energy absorption patterns inside the body and can create localised hotspots with a risk of overheating. The MRI + EUREKA research consortium organised a "Thermal Workshop on RF Hotspots". The available literature on thresholds for thermal damage and the validity of the thermal dose (TD) model were discussed. The following global TD threshold guidelines for safe use of MR are proposed: 1. All persons: maximum local temperature of any tissue limited to 39 °C 2. Persons with compromised thermoregulation AND (a) Uncontrolled conditions: maximum local temperature limited to 39 °C (b) Controlled conditions: TD < 2 CEM43°C 3. Persons with uncompromised thermoregulation AND (a) Uncontrolled conditions: TD < 2 CEM43°C (b) Controlled conditions: TD < 9 CEM43°C The following definitions are applied: Controlled conditions A medical doctor or a dedicated trained person can respond instantly to heat-induced physiological stress Compromised thermoregulation All persons with impaired systemic or reduced local thermoregulation • Standard MRI can cause local heating by radiofrequency absorption. • Monitoring thermal dose (in units of CEM43°C) can control risk during MRI. • 9 CEM43°C seems an acceptable thermal dose threshold for most patients. • For skin, muscle, fat and bone,16 CEM43°C is likely acceptable.

  13. 40 CFR 75.38 - Standard missing data procedures for Hg CEMS.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Standard missing data procedures for...) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Missing Data Substitution Procedures § 75.38 Standard missing data procedures for Hg CEMS. (a) Once 720 quality assured monitor operating hours of Hg...

  14. 40 CFR 63.427 - Continuous monitoring.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... concentration shall be installed in the exhaust air stream. (2) Where a refrigeration condenser system is used... immediately downstream from the outlet to the condenser section. Alternatively, a CEMS capable of measuring...

  15. 40 CFR Appendix to Subpart Eee of... - Quality Assurance Procedures for Continuous Emissions Monitors Used for Hazardous Waste Combustors

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... and CEMS control capabilities. 2.2Relative Accuracy (RA). The absolute mean difference between the... readings at the zero pollutant level after a stated period of operation during which no unscheduled... Evaluation for CO, O2, and HC CEMS Carbon Monoxide (CO), Oxygen (O2), and Hydrocarbon (HC) CEMS. An Absolute...

  16. 40 CFR Appendix to Subpart Eee of... - Quality Assurance Procedures for Continuous Emissions Monitors Used for Hazardous Waste Combustors

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... and CEMS control capabilities. 2.2Relative Accuracy (RA). The absolute mean difference between the... readings at the zero pollutant level after a stated period of operation during which no unscheduled... Evaluation for CO, O2, and HC CEMS Carbon Monoxide (CO), Oxygen (O2), and Hydrocarbon (HC) CEMS. An Absolute...

  17. 40 CFR 60.4335 - How do I demonstrate compliance for NOX if I use water or steam injection?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... monitor and record the fuel consumption and the ratio of water or steam to fuel being fired in the turbine... continuous emission monitoring system (CEMS) consisting of a NOX monitor and a diluent gas (oxygen (O2) or... rate, temperature, and pressure, to continuously measure the total thermal energy output in British...

  18. 40 CFR 60.4335 - How do I demonstrate compliance for NOX if I use water or steam injection?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... monitor and record the fuel consumption and the ratio of water or steam to fuel being fired in the turbine... continuous emission monitoring system (CEMS) consisting of a NOX monitor and a diluent gas (oxygen (O2) or... rate, temperature, and pressure, to continuously measure the total thermal energy output in British...

  19. 40 CFR 60.4335 - How do I demonstrate compliance for NOX if I use water or steam injection?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... monitor and record the fuel consumption and the ratio of water or steam to fuel being fired in the turbine... continuous emission monitoring system (CEMS) consisting of a NOX monitor and a diluent gas (oxygen (O2) or... rate, temperature, and pressure, to continuously measure the total thermal energy output in British...

  20. 40 CFR 60.4335 - How do I demonstrate compliance for NOX if I use water or steam injection?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... monitor and record the fuel consumption and the ratio of water or steam to fuel being fired in the turbine... continuous emission monitoring system (CEMS) consisting of a NOX monitor and a diluent gas (oxygen (O2) or... rate, temperature, and pressure, to continuously measure the total thermal energy output in British...

  1. 40 CFR 60.4335 - How do I demonstrate compliance for NOX if I use water or steam injection?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... monitor and record the fuel consumption and the ratio of water or steam to fuel being fired in the turbine... continuous emission monitoring system (CEMS) consisting of a NOX monitor and a diluent gas (oxygen (O2) or... rate, temperature, and pressure, to continuously measure the total thermal energy output in British...

  2. Status and Needs Research for On-line Monitoring of VOCs Emissions from Stationary Sources

    NASA Astrophysics Data System (ADS)

    Zhou, Gang; Wang, Qiang; Zhong, Qi; Zhao, Jinbao; Yang, Kai

    2018-01-01

    Based on atmospheric volatile organic compounds (VOCs) pollution control requirements during the twelfth-five year plan and the current status of monitoring and management at home and abroad, instrumental architecture and technical characteristics of continuous emission monitoring systems (CEMS) for VOCs emission from stationary sources are investigated and researched. Technological development needs of VOCs emission on-line monitoring techniques for stationary sources in china are proposed from the system sampling pretreatment technology and analytical measurement techniques.

  3. Protocol Gas Verification Program Audit Reports

    EPA Pesticide Factsheets

    View the full reports from 2010 and 2013 of the PGVP audits, which tested the EPA Protocol gases that are used to calibrate continuous emission monitoring systems (CEMS), and the instruments used in EPA reference methods.

  4. 40 CFR Appendix to Subpart Eee of... - Quality Assurance Procedures for Continuous Emissions Monitors Used for Hazardous Waste Combustors

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... capabilities. 2.2Relative Accuracy (RA). The absolute mean difference between the pollutant concentration... adjustment took place. 2.4Zero Drift (ZD). The difference in CEMS output readings at the zero pollutant level... Evaluation for CO, O2, and HC CEMS Carbon Monoxide (CO), Oxygen (O2), and Hydrocarbon (HC) CEMS. An Absolute...

  5. 40 CFR Appendix to Subpart Eee of... - Quality Assurance Procedures for Continuous Emissions Monitors Used for Hazardous Waste Combustors

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... capabilities. 2.2Relative Accuracy (RA). The absolute mean difference between the pollutant concentration... adjustment took place. 2.4Zero Drift (ZD). The difference in CEMS output readings at the zero pollutant level... Evaluation for CO, O2, and HC CEMS Carbon Monoxide (CO), Oxygen (O2), and Hydrocarbon (HC) CEMS. An Absolute...

  6. Development and Validation of a Collocated Exposure Monitoring Methodology using Portable Air Monitors

    NASA Astrophysics Data System (ADS)

    Li, Z.; Che, W.; Frey, H. C.; Lau, A. K. H.

    2016-12-01

    Portable air monitors are currently being developed and used to enable a move towards exposure monitoring as opposed to fixed site monitoring. Reliable methods are needed regarding capturing spatial and temporal variability in exposure concentration to obtain credible data from which to develop efficient exposure mitigation measures. However, there are few studies that quantify the validity and repeatability of the collected data. The objective of this study is to present and evaluate a collocated exposure monitoring (CEM) methodology including the calibration of portable air monitors against stationary reference equipment, side-by-side comparison of portable air monitors, personal or microenvironmental exposure monitoring and the processing and interpretation of the collected data. The CEM methodology was evaluated based on application to portable monitors TSI DustTrak II Aerosol Monitor 8530 for fine particulate matter (PM2.5) and TSI Q-Trak model 7575 with probe model 982 for CO, CO2, temperature and relative humidity. Taking a school sampling campaign in Hong Kong in January and June, 2015 as an example, the calibrated side-by-side measured 1 Hz PM2.5 concentrations showed good consistency between two sets of portable air monitors. Confidence in side-by-side comparison, PM2.5 concentrations of which most of the time were within 2 percent, enabled robust inference regarding differences when the monitors measured in classroom and pedestrian during school hour. The proposed CEM methodology can be widely applied in sampling campaigns with the objective of simultaneously characterizing pollutant concentrations in two or more locations or microenvironments. The further application of the CEM methodology to transportation exposure will be presented and discussed.

  7. Carbon dioxide emission tallies for 210 U.S. coal-fired power plants: a comparison of two accounting methods.

    PubMed

    Quick, Jeffrey C

    2014-01-01

    Annual CO2 emission tallies for 210 coal-fired power plants during 2009 were more accurately calculated from fuel consumption records reported by the US. Energy Information Administration (EIA) than measurements from Continuous Emissions Monitoring Systems (CEMS) reported by the US. Environmental Protection Agency. Results from these accounting methods for individual plants vary by +/- 10.8%. Although the differences systematically vary with the method used to certify flue-gas flow instruments in CEMS, additional sources of CEMS measurement error remain to be identified. Limitations of the EIA fuel consumption data are also discussed. Consideration of weighing, sample collection, laboratory analysis, emission factor, and stock adjustment errors showed that the minimum error for CO2 emissions calculated from the fuel consumption data ranged from +/- 1.3% to +/- 7.2% with a plant average of +/- 1.6%. This error might be reduced by 50% if the carbon content of coal delivered to U.S. power plants were reported. Potentially, this study might inform efforts to regulate CO2 emissions (such as CO2 performance standards or taxes) and more immediately, the U.S. Greenhouse Gas Reporting Rule where large coal-fired power plants currently use CEMS to measure CO2 emissions. Moreover, if, as suggested here, the flue-gas flow measurement limits the accuracy of CO2 emission tallies from CEMS, then the accuracy of other emission tallies from CEMS (such as SO2, NOx, and Hg) would be similarly affected. Consequently, improved flue gas flow measurements are needed to increase the reliability of emission measurements from CEMS.

  8. 40 CFR 98.164 - Monitoring and QA/QC requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... CEMS is not used to measure GHG emissions. (2) Fossil fuel consumption, when, pursuant to § 98.33(e), the owner or operator of a unit that uses CEMS to quantify CO2 emissions and that combusts both fossil...

  9. 40 CFR 98.164 - Monitoring and QA/QC requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... CEMS is not used to measure GHG emissions. (2) Fossil fuel consumption, when, pursuant to § 98.33(e), the owner or operator of a unit that uses CEMS to quantify CO2 emissions and that combusts both fossil...

  10. 40 CFR 63.6625 - What are my monitoring, installation, collection, operation, and maintenance requirements?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... requirements? (a) If you elect to install a CEMS as specified in Table 5 of this subpart, you must install... periodic data quality checks in accordance with 40 CFR part 60, appendix F, procedure 1. (3) As specified... you are required to install a continuous parameter monitoring system (CPMS) as specified in Table 5 of...

  11. 40 CFR 63.2164 - If I monitor brew ethanol, what are my monitoring installation, operation, and maintenance...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... specifications and in accordance with § 63.6(e)(1). (b) Each CEMS must complete a minimum of one cycle of... cycles of operation in a 1-hour period to have a valid hour of data. (c) The CEMS data must be reduced to... water (0.05 percent, 0.15 percent, and 0.3 percent). (2) For use in calibrating the GC, prepare the...

  12. Mercury Emission Measurement in Coal-Fired Boilers by Continuous Mercury Monitor and Ontario Hydro Method

    NASA Astrophysics Data System (ADS)

    Zhu, Yanqun; Zhou, Jinsong; He, Sheng; Cai, Xiaoshu; Hu, Changxin; Zheng, Jianming; Zhang, Le; Luo, Zhongyang; Cen, Kefa

    2007-06-01

    The mercury emission control approach attaches more importance. The accurate measurement of mercury speciation is a first step. Because OH method (accepted method) can't provide the real-time data and 2-week time for results attained, it's high time to seek on line mercury continuous emission monitors(Hg-CEM). Firstly, the gaseous elemental and oxidized mercury were conducted to measure using OH and CEM method under normal operation conditions of PC boiler after ESP, the results between two methods show good consistency. Secondly, through ESP, gaseous oxidized mercury decrease a little and particulate mercury reduce a little bit, but the elemental mercury is just the opposite. Besides, the WFGD system achieved to gaseous oxidized mercury removal of 53.4%, gaseous overall mercury and elemental mercury are 37.1% and 22.1%, respectively.

  13. The Civitavecchia Coastal Environment Monitoring System (C-CEMS): an integrated approach to the study of coastal oceanographic processes

    NASA Astrophysics Data System (ADS)

    Marcelli, Marco; Piermattei, Viviana; Madonia, Alice; Bonamano, Simone; Martellucci, Riccardo; Pierattini, Alberto; Albani, Marta; Borsellino, Chiara; Zappalà, Giuseppe

    2015-04-01

    The study of the physical and biological processes of the coastal environment, characterized by high spatial and time variability, requires the adoption of multidisciplinary strategies of investigation that takes into account, not only the biotic and abiotic components of coastal marine ecosystems, but also the terrestrial, atmospheric and hydrological features linked to them. The understanding of coastal environment is fundamental to face efficiently and effectively the pollution phenomena, as expected by Marine Strategy (2008/56 EC) Directive, which is focused on the achievement of GES by 2020 in all Member States. Following these lines, the Laboratory of Experimental Oceanology and Marine Ecology (University of Tuscia) has developed a multi-platform observing network (the Civitavecchia Coastal Environment Monitoring System, C-CEMS) that operates since 2005 in the coastal marine area of Civitavecchia (northern Tyrrhenian Sea, Italy), where multiple uses (industrial, commercial and tourist activities) and high ecological values (Posidonia oceanica meadows, hard-bottom benthic communities, priority species, etc.) closely coexist. Furthermore, in the last years the Civitavecchia harbour, which is one of the main ports of Europe, has been subjected to a series of expansion works that could impact significantly on the coastal environment. The C-CEMS, implemented in the current configuration, is composed by five main modules (fixed stations, in-situ measurements and samplings, satellite observations, numerical models, GIS) which provide integrated informations to be used in different fields of the environmental research. The fixed stations system controls one weather, two water quality and two wave-buoy stations along the coast. In addition to the long term observations acquired by the fixed stations (L-TER), in situ surveys are periodically carried out for the monitoring of the physical, chemical and biological characteristics of the water column and marine sediments as well as of the benthic biota. The in situ data, integrated with satellite observations (temperature, chlorophyll a and TSM), are used to feed and validate the numerical models, which allow to analyse and forecast the dynamics of conservative and non-conservative particles under different conditions. Finally, the C-CEMS informations combined with diverse kind of datasets (fishery, land use, hydrology, orography, archeologic, naturalistic, etc) can be represented in thematic maps called Sea Uses Maps, supporting the management decisions of the stakeholders. As examples of C-CEMS applications two case studies are reported in this work: the analysis of faecal bacteria dispersion for bathing water quality assessment, and the evaluation of the effects of the dredged activities on Posidonia meadows and soft-bottom benthic communities.

  14. Recommendations on the choice of gas analysis equipment for systems of continuous monitoring and accounting of emissions from thermal power plants

    NASA Astrophysics Data System (ADS)

    Kondrat'eva, O. E.; Roslyakov, P. V.; Burdyukov, D. A.; Khudolei, O. D.; Loktionov, O. A.

    2017-10-01

    According to Federal Law no. 219-FZ, dated July 21, 2014, all enterprises that have a significant negative impact on the environment shall continuously monitor and account emissions of harmful substances into the atmospheric air. The choice of measuring equipment that is included in continuous emission monitoring and accounting systems (CEM&ASs) is a complex technical problem; in particular, its solution requires a comparative analysis of gas analysis systems; each of these systems has its advantages and disadvantages. In addition, the choice of gas analysis systems for CEM&ASs should be maximally objective and not depend on preferences of separate experts and specialists. The technique of choosing gas analysis equipment that was developed in previous years at Moscow Power Engineering Institute (MPEI) has been analyzed and the applicability of the mathematical tool of a multiple criteria analysis to choose measuring equipment for the continuous emission monitoring and accounting system have been estimated. New approaches to the optimal choice of gas analysis equipment for systems of the continuous monitoring and accounting of harmful emissions from thermal power plants have been proposed, new criteria of evaluation of gas analysis systems have been introduced, and weight coefficients have been determined for these criteria. The results of this study served as a basis for the Preliminary National Standard of the Russian Federation "Best Available Technologies. Automated Systems of Continuous Monitoring and Accounting of Emissions of Harmful (Polluting) Substances from Thermal Power Plants into the Atmospheric Air. Basic Requirements," which was developed by the Moscow Power Engineering Institute, National Research University, in cooperation with the Council of Power Producers and Strategic Electric Power Investors Association and the All-Russia Research Institute for Materials and Technology Standardization.

  15. 40 CFR 63.7947 - What are my monitoring alternatives?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...). (3) You must conduct a performance evaluation of the CEMS according to the requirements in § 63.8 and Performance Specification 8 (for a total organic emissions CEMS) or Performance Specification 9 (for a HAP...? 63.7947 Section 63.7947 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR...

  16. A novel dual luciferase assay for the simultaneous monitoring of HIV infection and cell viability.

    PubMed

    Mitsuki, Yu-Ya; Yamamoto, Takuya; Mizukoshi, Fuminori; Momota, Masatoshi; Terahara, Kazutaka; Yoshimura, Kazuhisa; Harada, Shigeyoshi; Tsunetsugu-Yokota, Yasuko

    2016-05-01

    Human immunodeficiency virus type 1 (HIV-1) reporter cell lines are critical tools for drug development. However, one disadvantage of HIV-1 reporter cell lines is that reductions in reporter gene activity need to be normalized to cytotoxicity, i.e., live cell numbers. Here, we developed a dual luciferase assay based on a R. reniformis luciferase (hRLuc)-expressing R5-type HIV-1 (NLAD8-hRLuc) and a CEM cell line expressing CCR5 and firefly luciferase (R5CEM-FiLuc). The NLAD8-hRLuc reporter virus was replication competent in peripheral blood mononuclear cells. The level of hRLuc was correlated with p24 antigen levels (p<0.001, R=0.862). The target cell line, R5CEM-FiLuc, stably expressed the firefly luciferase (FiLuc) reporter gene and allowed the simultaneous monitoring of compound cytotoxicity. The dual reporter assay combining a NLAD8-hRLuc virus with R5CEM-FiLuc cells permitted the accurate determination of drug susceptibility for entry, reverse transcriptase, integrase, and protease inhibitors at different multiplicities of infection. This dual reporter assay provides a rapid and direct method for the simultaneous monitoring of HIV infection and cell viability. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. 40 CFR 63.6625 - What are my monitoring, installation, collection, operation, and maintenance requirements?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... CEMS must be installed at both the inlet and outlet of the control device. If you are meeting a requirement to limit the concentration of CO, the CEMS must be installed at the outlet of the control device... appropriate for the applicable limitation) at 15 percent oxygen or the equivalent CO2 concentration. (b) If...

  18. 76 FR 49303 - Approval and Promulgation of Air Quality Implementation Plans; Minnesota; Rules Update

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-10

    ... design requirements for the monitoring systems. The revised CMS rules also delineate the recordkeeping..., [Insert page number where the document begins]. 7017.1140 CEMS design 03/01/99 08/10/11, [Insert page...]. 7017.1190 COMS design 03/01/99 08/10/11, [Insert page requirements. number where the document begins...

  19. 40 CFR 63.10009 - May I use emissions averaging to comply with this subpart?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... performance test must not be less than the design efficiency of the emissions control technology employed 180... properties, belonging to a single major industrial grouping, which are under common control of the same person (or persons under common control); and (ii) You use CEMS (or sorbent trap monitoring systems for...

  20. 40 CFR 63.10009 - May I use emissions averaging to comply with this subpart?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... performance test must not be less than the design efficiency of the emissions control technology employed 180... properties, belonging to a single major industrial grouping, which are under common control of the same person (or persons under common control); and (ii) You use CEMS (or sorbent trap monitoring systems for...

  1. A semantic-web oriented representation of the clinical element model for secondary use of electronic health records data.

    PubMed

    Tao, Cui; Jiang, Guoqian; Oniki, Thomas A; Freimuth, Robert R; Zhu, Qian; Sharma, Deepak; Pathak, Jyotishman; Huff, Stanley M; Chute, Christopher G

    2013-05-01

    The clinical element model (CEM) is an information model designed for representing clinical information in electronic health records (EHR) systems across organizations. The current representation of CEMs does not support formal semantic definitions and therefore it is not possible to perform reasoning and consistency checking on derived models. This paper introduces our efforts to represent the CEM specification using the Web Ontology Language (OWL). The CEM-OWL representation connects the CEM content with the Semantic Web environment, which provides authoring, reasoning, and querying tools. This work may also facilitate the harmonization of the CEMs with domain knowledge represented in terminology models as well as other clinical information models such as the openEHR archetype model. We have created the CEM-OWL meta ontology based on the CEM specification. A convertor has been implemented in Java to automatically translate detailed CEMs from XML to OWL. A panel evaluation has been conducted, and the results show that the OWL modeling can faithfully represent the CEM specification and represent patient data.

  2. A semantic-web oriented representation of the clinical element model for secondary use of electronic health records data

    PubMed Central

    Tao, Cui; Jiang, Guoqian; Oniki, Thomas A; Freimuth, Robert R; Zhu, Qian; Sharma, Deepak; Pathak, Jyotishman; Huff, Stanley M; Chute, Christopher G

    2013-01-01

    The clinical element model (CEM) is an information model designed for representing clinical information in electronic health records (EHR) systems across organizations. The current representation of CEMs does not support formal semantic definitions and therefore it is not possible to perform reasoning and consistency checking on derived models. This paper introduces our efforts to represent the CEM specification using the Web Ontology Language (OWL). The CEM-OWL representation connects the CEM content with the Semantic Web environment, which provides authoring, reasoning, and querying tools. This work may also facilitate the harmonization of the CEMs with domain knowledge represented in terminology models as well as other clinical information models such as the openEHR archetype model. We have created the CEM-OWL meta ontology based on the CEM specification. A convertor has been implemented in Java to automatically translate detailed CEMs from XML to OWL. A panel evaluation has been conducted, and the results show that the OWL modeling can faithfully represent the CEM specification and represent patient data. PMID:23268487

  3. Air Quality Monitor

    NASA Technical Reports Server (NTRS)

    1996-01-01

    The Stak-Tracker CEM (Continuous Emission Monitor) Gas Analyzer is an air quality monitor capable of separating the various gases in a bulk exhaust stream and determining the amounts of individual gases present within the stream. The monitor is produced by GE Reuter- Stokes, a subsidiary of GE Corporate Research & Development Center. The Stak-Tracker uses a Langley Research Center software package which measures the concentration of a target gas by determining the degree to which molecules of that gas absorb an infrared beam. The system is environmental-friendly, fast and has relatively low installation and maintenance costs. It is applicable to gas turbines and various industries including glass, paper and cement.

  4. 40 CFR 63.562 - Standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... barrels per day; and (C) For 1997, 1,445,000 barrels per day. (ii) Maximum extent practicable means that... (thermocouples, pressure transducers, continuous emissions monitors (CEMS), etc.) variances. (i) The plan shall... monitoring equipment functions properly and variances of the control equipment and monitoring equipment are...

  5. EPA Protocol Gas Verification Program

    EPA Science Inventory

    Accurate compressed gas calibration standards are needed to calibrate continuous emission monitors (CEMs) and ambient air quality monitors that are being used for regulatory purposes. US Environmental Protection Agency (EPA) established its traceability protocol to ensure that co...

  6. CEM data quality: Survey of the utility industry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mitnick, S.A.; Wade, S.

    1995-09-01

    The Acid Rain Allowance Trading program of the Clean Air Act Amendments of 1990 (CAAA) represents a spectacular departure from traditional Command-and-Control regulation. The program is noteworthy both in its scale and because, defacto, it turns the pollutant Sulfur Dioxide (SO{sub 2}) into a valuable asset. The market has responded accordingly with the development of an infrastructure to support the financial aspects of the program; it includes the Electronic Emission Tracking System, the Chicago Board of Trade`s SO{sub 2} Allowance Futures Market and, more recently, Cantor Fitzgerald`s Market Price Index (MPI). While this may increase the potential for successful implementationmore » of the allowance market, one should not lose sight of the fact that these institutional supports are the trappings of an emission reduction program, not the substance. The allowance trading program will not work unless it meets its environmental goals. Continuous Emission Monitoring (CEM) requirements in the CAAA address this concern by providing the infrastructure to support the environmental aspects of the allowance trading program. CEM systems are relied upon to provide accurate, quality-assured emissions data. This information is critical to the success of the allowance trading program in the eyes of both the general public and the financial/utility community. December 31, 1994 marked the close of the fifth CEM reporting quarter since the program was initiated in November 1993. Since that time, the electric utility industry has submitted over 1,000 quarterly reports, known as electronic data reports (EDRs), to EPA. Hagler Bailly evaluated the quality of data contained in these EDRs using Superbase, software it developed to perform this task. This paper presents selected findings from that review.« less

  7. 40 CFR Table 7 to Subpart Mmmmm of... - Applicability of General Provisions to Subpart MMMMM

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... alternative test method Yes. § 63.7(g) Performance test data analysis, recordkeeping, and reporting Yes. § 63... emissions monitoring systems (CEMS). § 63.8(g) Data reduction Yes Applies as modified by § 63.8794(g). § 63... CMS notifications—date of CMS performance evaluation Yes. § 63.9(g)(2) Use of COMS data No Subpart...

  8. Study on advanced information processing system

    NASA Technical Reports Server (NTRS)

    Shin, Kang G.; Liu, Jyh-Charn

    1992-01-01

    Issues related to the reliability of a redundant system with large main memory are addressed. In particular, the Fault-Tolerant Processor (FTP) for Advanced Launch System (ALS) is used as a basis for our presentation. When the system is free of latent faults, the probability of system crash due to nearly-coincident channel faults is shown to be insignificant even when the outputs of computing channels are infrequently voted on. In particular, using channel error maskers (CEMs) is shown to improve reliability more effectively than increasing the number of channels for applications with long mission times. Even without using a voter, most memory errors can be immediately corrected by CEMs implemented with conventional coding techniques. In addition to their ability to enhance system reliability, CEMs--with a low hardware overhead--can be used to reduce not only the need of memory realignment, but also the time required to realign channel memories in case, albeit rare, such a need arises. Using CEMs, we have developed two schemes, called Scheme 1 and Scheme 2, to solve the memory realignment problem. In both schemes, most errors are corrected by CEMs, and the remaining errors are masked by a voter.

  9. Study on fault-tolerant processors for advanced launch system

    NASA Technical Reports Server (NTRS)

    Shin, Kang G.; Liu, Jyh-Charn

    1990-01-01

    Issues related to the reliability of a redundant system with large main memory are addressed. The Fault-Tolerant Processor (FTP) for the Advanced Launch System (ALS) is used as a basis for the presentation. When the system is free of latent faults, the probability of system crash due to multiple channel faults is shown to be insignificant even when voting on the outputs of computing channels is infrequent. Using channel error maskers (CEMs) is shown to improve reliability more effectively than increasing redundancy or the number of channels for applications with long mission times. Even without using a voter, most memory errors can be immediately corrected by those CEMs implemented with conventional coding techniques. In addition to their ability to enhance system reliability, CEMs (with a very low hardware overhead) can be used to dramatically reduce not only the need of memory realignment, but also the time required to realign channel memories in case, albeit rare, such a need arises. Using CEMs, two different schemes were developed to solve the memory realignment problem. In both schemes, most errors are corrected by CEMs, and the remaining errors are masked by a voter.

  10. CEM-designer: design of custom expression microarrays in the post-ENCODE Era.

    PubMed

    Arnold, Christian; Externbrink, Fabian; Hackermüller, Jörg; Reiche, Kristin

    2014-11-10

    Microarrays are widely used in gene expression studies, and custom expression microarrays are popular to monitor expression changes of a customer-defined set of genes. However, the complexity of transcriptomes uncovered recently make custom expression microarray design a non-trivial task. Pervasive transcription and alternative processing of transcripts generate a wealth of interweaved transcripts that requires well-considered probe design strategies and is largely neglected in existing approaches. We developed the web server CEM-Designer that facilitates microarray platform independent design of custom expression microarrays for complex transcriptomes. CEM-Designer covers (i) the collection and generation of a set of unique target sequences from different sources and (ii) the selection of a set of sensitive and specific probes that optimally represents the target sequences. Probe design itself is left to third party software to ensure that probes meet provider-specific constraints. CEM-Designer is available at http://designpipeline.bioinf.uni-leipzig.de. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. A CRF-based system for recognizing chemical entity mentions (CEMs) in biomedical literature

    PubMed Central

    2015-01-01

    Background In order to improve information access on chemical compounds and drugs (chemical entities) described in text repositories, it is very crucial to be able to identify chemical entity mentions (CEMs) automatically within text. The CHEMDNER challenge in BioCreative IV was specially designed to promote the implementation of corresponding systems that are able to detect mentions of chemical compounds and drugs, which has two subtasks: CDI (Chemical Document Indexing) and CEM. Results Our system processing pipeline consists of three major components: pre-processing (sentence detection, tokenization), recognition (CRF-based approach), and post-processing (rule-based approach and format conversion). In our post-challenge system, the cost parameter in CRF model was optimized by 10-fold cross validation with grid search, and word representations feature induced by Brown clustering method was introduced. For the CEM subtask, our official runs were ranked in top position by obtaining maximum 88.79% precision, 69.08% recall and 77.70% balanced F-measure, which were improved further to 88.43% precision, 76.48% recall and 82.02% balanced F-measure in our post-challenge system. Conclusions In our system, instead of extracting a CEM as a whole, we regarded it as a sequence labeling problem. Though our current system has much room for improvement, our system is valuable in showing that the performance in term of balanced F-measure can be improved largely by utilizing large amounts of relatively inexpensive un-annotated PubMed abstracts and optimizing the cost parameter in CRF model. From our practice and lessons, if one directly utilizes some open-source natural language processing (NLP) toolkits, such as OpenNLP, Standford CoreNLP, false positive (FP) rate may be very high. It is better to develop some additional rules to minimize the FP rate if one does not want to re-train the related models. Our CEM recognition system is available at: http://www.SciTeMiner.org/XuShuo/Demo/CEM. PMID:25810768

  12. The design, development, and implementation of a data acquisition and handling system at Basin Electric Power Cooperative

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baranowski, S.T.; Culp, L.R.; Jonas, T.S.

    1995-12-31

    The Clean Air Act Amendments of 1990 require all Phase 1 and 2 utilities to install Continuous Emissions Monitoring Systems (CEMS), which can consist of instrumentation including analyzers and a Data Acquisition and Handling System (DAHS). To meet these requirements, Basin Electric Power Cooperative contracted with Black and Veatch to design and develop a DAHS which would meet all 40 CFR Part 75 requirements. Basin Electric provided the specifications for the DAHS and the graphical user interface, and B and V designed, developed, and installed a DAHS at 3 units at Laramie River Station, 2 units at Antelope Valley Station,more » and 2 units at Leland Olds Station. B and V utilized the existing equipment, adding to it a unique DAHS design. B and V designed and implemented the DAHS which operates in the OS/2 environment to interface with multiple programmable logic controllers. This unique software was written in modular form so that multiple programs run in unison, monitoring each other for errors to ensure continuous operation. The reporting structure is flexible to allow for a variety of formats, including those specifically required by the state to meet CAAA guidelines. Today, these seven units are in operation and comply with the CAAA. This paper describes the issues faced during specification, general design, compliance, and implementation of the DAHS at BEPC, including the lessons learned. The continuous emissions monitoring (CEM) system for each unit at BEPC consisted of a set of dilution probe analyzers for measuring SO{sub 2}, NO{sub x}, and CO{sub 2}.« less

  13. Performance Efficiency of a Crash Energy Management System

    DOT National Transportation Integrated Search

    2007-03-13

    Previous work has led to the development of a crash energy : management (CEM) system designed to distribute crush : throughout unoccupied areas of a passenger train in a collision : event. This CEM system is comprised of crush zones at the : front an...

  14. The Influence of Manufacturing Variations on a Crash Energy Management System

    DOT National Transportation Integrated Search

    2008-09-24

    Crash Energy Management (CEM) systems protect passengers in the event of a train collision. A CEM system distributes crush throughout designated unoccupied crush zones of a passenger rail consist. This paper examines the influence of manufacturing va...

  15. Current Status of EPA Protocol Gas Verification Program

    EPA Science Inventory

    Accurate compressed gas reference standards are needed to calibrate and audit continuous emission monitors (CEMs) and ambient air quality monitors that are being used for regulatory purposes. US Environmental Protection Agency (EPA) established its traceability protocol to ensur...

  16. Channel electron multiplier compatibility with Viton and Apiezon-L vacuum grease

    NASA Astrophysics Data System (ADS)

    McComas, D. J.; Baldonado, J. R.; Bame, S. J.; Barraclough, B. L.

    1987-12-01

    Clean Viton and Viton coated with Apiezon-L vacuum grease were tested for their noncontaminating compatibility with channel electron multipliers (CEMs). The test setup and procedure were the same as those used previously in conjunction with CEM compatibility tests of certain epoxies, solder, and fluorocarbon polymer materials useful for construction of spaceflight sensors. While some CEM gain degradation was noted during exposure to Viton and Apiezon-L, the present tests indicate that, at least over instrument lifetimes of about 2 x 10 to the 12th counts, these materials should be suitable for (1) preflight space sensor testing systems, (2) hermetic seals for CEM-based space sensors, and (3) terrestrial CEM-based instrumentation.

  17. CURRENT STATUS OF THE EPA PROTOCOL GAS PROGRAM

    EPA Science Inventory

    Accurate compressed gas calibration standards are needed to calibrate continuous emission monitors (CEMs) and ambient air quality monitors that are being used for regulatory purposes. EPA has published a protocol to establish the traceability of these standards to national refer...

  18. Current Status of EPA Verification Program for EPA Protocol Gases

    EPA Science Inventory

    Accurate compressed gas calibration standards are needed to calibrate continuous emission monitors (CEMs) and ambient air quality monitors that are being used for regulatory purposes. US Environmental Protection Agency (EPA) established its traceability protocol to ensure that c...

  19. EPA Protocol Gas Verification Program - Presented at NIST Gas Panel Meeting

    EPA Science Inventory

    Accurate compressed gas calibration standards are needed to calibrate continuous emission monitors (CEMs) and ambient air quality monitors that are being used for regulatory purposes. US Environmental Protection Agency (EPA) established its traceability protocol to ensure that c...

  20. 40 CFR Table 7 to Subpart Nnnnn of... - Applicability of General Provisions to Subpart NNNNN

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Yes. § 63.7(f) Use of an alternative test method Yes. § 63.7(g) Performance test data analysis... Only applies to sources that use continuous emissions monitoring systems (CEMS). § 63.8(g) Data... evaluation Yes. § 63.9(g)(2) Use of COMS data No Subpart NNNNN does not require the use of COMS. § 63.9(g)(3...

  1. Aerosol Beam Focused-Laser Induced Plasma Spectrometer (ABF-LIPS) Continuous Emissions Multi-Metals Analyzer

    DTIC Science & Technology

    2012-06-01

    heating are possible, but will add to system cost. 6.5 LESSONS LEARNED Reliable spiking of the airstream with metals proved to be a challenge . Based on...designed to allow calibration of the CEMS by use of standard solutions, filters, etc that challenge the pollutant analyzer part of the CEMS (and as much...of the whole system as possible), but which do not challenge the entire CEMS, including the sampling interface. Satisfactory response of the entire

  2. Assessment and Optimization of the Accuracy of an Aircraft-Based Technique Used to Quantify Greenhouse Gas Emission Rates from Point Sources

    NASA Astrophysics Data System (ADS)

    Shepson, P. B.; Lavoie, T. N.; Kerlo, A. E.; Stirm, B. H.

    2016-12-01

    Understanding the contribution of anthropogenic activities to atmospheric greenhouse gas concentrations requires an accurate characterization of emission sources. Previously, we have reported the use of a novel aircraft-based mass balance measurement technique to quantify greenhouse gas emission rates from point and area sources, however, the accuracy of this approach has not been evaluated to date. Here, an assessment of method accuracy and precision was performed by conducting a series of six aircraft-based mass balance experiments at a power plant in southern Indiana and comparing the calculated CO2 emission rates to the reported hourly emission measurements made by continuous emissions monitoring systems (CEMS) installed directly in the exhaust stacks at the facility. For all flights, CO2 emissions were quantified before CEMS data were released online to ensure unbiased analysis. Additionally, we assess the uncertainties introduced to the final emission rate caused by our analysis method, which employs a statistical kriging model to interpolate and extrapolate the CO2 fluxes across the flight transects from the ground to the top of the boundary layer. Subsequently, using the results from these flights combined with the known emissions reported by the CEMS, we perform an inter-model comparison of alternative kriging methods to evaluate the performance of the kriging approach.

  3. Hypoactive medial prefrontal cortex functioning in adults reporting childhood emotional maltreatment.

    PubMed

    van Harmelen, Anne-Laura; van Tol, Marie-José; Dalgleish, Tim; van der Wee, Nic J A; Veltman, Dick J; Aleman, André; Spinhoven, Philip; Penninx, Brenda W J H; Elzinga, Bernet M

    2014-12-01

    Childhood emotional maltreatment (CEM) has adverse effects on medial prefrontal cortex (mPFC) morphology, a structure that is crucial for cognitive functioning and (emotional) memory and which modulates the limbic system. In addition, CEM has been linked to amygdala hyperactivity during emotional face processing. However, no study has yet investigated the functional neural correlates of neutral and emotional memory in adults reporting CEM. Using functional magnetic resonance imaging, we investigated CEM-related differential activations in mPFC during the encoding and recognition of positive, negative and neutral words. The sample (N = 194) consisted of patients with depression and/or anxiety disorders and healthy controls (HC) reporting CEM (n = 96) and patients and HC reporting no abuse (n = 98). We found a consistent pattern of mPFC hypoactivation during encoding and recognition of positive, negative and neutral words in individuals reporting CEM. These results were not explained by psychopathology or severity of depression or anxiety symptoms, or by gender, level of neuroticism, parental psychopathology, negative life events, antidepressant use or decreased mPFC volume in the CEM group. These findings indicate mPFC hypoactivity in individuals reporting CEM during emotional and neutral memory encoding and recognition. Our findings suggest that CEM may increase individuals' risk to the development of psychopathology on differential levels of processing in the brain; blunted mPFC activation during higher order processing and enhanced amygdala activation during automatic/lower order emotion processing. These findings are vital in understanding the long-term consequences of CEM. © The Author (2014). Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.

  4. 40 CFR 60.2165 - What monitoring equipment must I install and what parameters must I monitor?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... installed in each baghouse compartment or cell. For negative pressure or induced air fabric filters, the bag... hydrogen chloride testing with EPA Method 321 at 40 CFR part 63, appendix A, an owner or operator must install, calibrate, maintain, and operate a CEMS for monitoring hydrogen chloride emissions discharged to...

  5. Evaluation of mist-netting, nest-searching and other methods for monitoring demographic processes in landbird populations

    Treesearch

    Nadav Nur; Geoffrey R. Geupel

    1993-01-01

    Demographic processes (reproductive success, survival of young and adults, recruitment of young into the breeding population) are critical to monitoring and managing landbird populations. We discuss different techniques that have been used to monitor these demographic processes in landbird populations, focusing on constant-effort mist-netting (CEM). We assess whether...

  6. 40 CFR 63.6625 - What are my monitoring, installation, collection, operation, and maintenance requirements?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., operate, and maintain a CEMS to monitor CO and either O2 or CO2 according to the requirements in... program must be part of the maintenance plan for the engine. (j) If you own or operate a stationary SI...

  7. Public-Private roundtables at the fourth Clean Energy Ministerial, 17-18 April 2013, New Delhi, India

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crowe, Tracey

    2013-06-30

    The Clean Energy Ministerial (CEM) is a high-level global forum to share best practices and promote policies and programs that advance clean energy technologies and accelerate the transition to a global clean energy economy. The CEM works to increase energy efficiency, expand clean energy supply, and enhance clean energy access worldwide. To achieve these goals, the CEM pursues a three-part strategy that includes high-level policy dialogue, technical cooperation, and engagement with the private sector and other stakeholders. Each year, energy ministers and other high-level delegates from the 23 participating CEM governments come together to discuss clean energy, review clean energymore » progress, and identify tangible next steps to accelerate the clean energy transition. The U.S. Department of Energy, which played a crucial role in launching the CEM, hosted the first annual meeting of energy ministers in Washington, DC, in June 2010. The United Arab Emirates hosted the second Clean Energy Ministerial in 2011, and the United Kingdom hosted the third Clean Energy Ministerial in 2012. In April 2013, India hosted the fourth Clean Energy Ministerial (CEM4) in New Delhi. Key insights from CEM4 are summarized in the report. It captures the ideas and recommendations of the government and private sector leaders who participated in the discussions on six discussion topics: reducing soft costs of solar PV; energy management systems; renewables policy and finance; clean vehicle adoption; mini-grid development; and power systems in emerging economies.« less

  8. Comparison of central corneal thickness and endothelial cell measurements by Scheimpflug camera system and two noncontact specular microscopes.

    PubMed

    Karaca, Irmak; Yilmaz, Suzan Guven; Palamar, Melis; Ates, Halil

    2017-07-03

    To investigate the correlation of Scheimpflug camera system and two noncontact specular microscopes in terms of central corneal thickness (CCT) and corneal endothelial cell morphology measurements. One hundred eyes of 50 healthy subjects were examined by Pentacam Scheimpflug Analyzer, CEM-530 (Nidek Co, Ltd, Gamagori, Japan) and CellChek XL (Konan Medical, California, USA) via fully automated image analysis with no corrections made. Measurement differences and agreement between instruments were determined by intraclass correlation analysis. The mean age of the subjects was 36.74 ± 8.59 (range 22-57). CCTs were well correlated among all devices, with having CEM-530 the thinnest and CellChek XL the thickest measurements (intraclass correlation coefficient (ICC) = 0.83; p < 0.001 and ICC = 0.78; p < 0.001, respectively). Mean endothelial cell density (ECD) given by CEM-530 was lower than CellChek XL (2613.17 ± 228.62 and 2862.72 ± 170.42 cells/mm 2 , respectively; ICC = 0.43; p < 0.001). Mean value for coefficient of variation (CV) was 28.57 ± 3.61 in CEM-530 and 30.30 ± 3.53 in CellChek XL. Cell hexagonality (HEX) with CEM-530 was higher than with CellChek XL (68.70 ± 4.16% and 45.19 ± 6.58%, respectively). ECDs with CellChek XL and CEM-530 have good correlation, but the values obtained by CellChek XL are higher than CEM-530. Measurements for HEX and CV differ significantly and show weak correlation. Thus, we do not recommend interchangeable use of CellChek XL and CEM-530. In terms of CCTs, Pentacam, CEM-530 and CellChek XL specular microscopy instruments are reliable devices.

  9. The Civitavecchia Coastal Environment Monitoring System (C-CEMS): a new tool to analyze the conflicts between coastal pressures and sensitivity areas

    NASA Astrophysics Data System (ADS)

    Bonamano, S.; Piermattei, V.; Madonia, A.; Paladini de Mendoza, F.; Pierattini, A.; Martellucci, R.; Stefanì, C.; Zappalà, G.; Caruso, G.; Marcelli, M.

    2016-01-01

    The understanding of the coastal environment is fundamental for efficiently and effectively facing the pollution phenomena as expected by the Marine Strategy Framework Directive, and for limiting the conflicts between anthropic activities and sensitivity areas, as stated by Maritime Spatial Planning Directive. To address this, the Laboratory of Experimental Oceanology and Marine Ecology developed a multi-platform observing network that has been in operation since 2005 in the coastal marine area of Civitavecchia (Latium, Italy) where multiple uses and high ecological values closely coexist. The Civitavecchia Coastal Environment Monitoring System (C-CEMS), implemented in the current configuration, includes various components allowing one to analyze the coastal conflicts by an ecosystem-based approach. The long-term observations acquired by the fixed stations are integrated with in situ data collected for the analysis of the physical, chemical and biological parameters of the water column, sea bottom and pollution sources detected along the coast. The in situ data, integrated with satellite observations (e.g., temperature, chlorophyll a and TSM), are used to feed and validate the numerical models, which allow the analysis and forecasting of the dynamics of pollutant dispersion under different conditions. To test the potential capabilities of C-CEMS, two case studies are reported here: (1) the analysis of fecal bacteria dispersion for bathing water quality assessment, and (2) the evaluation of the effects of the dredged activities on Posidonia meadows, which make up most of the two sites of community importance located along the Civitavecchia coastal zone. The simulation outputs are overlapped by the thematic maps showing bathing areas and Posidonia oceanica distribution, thus giving a first practical tool that could improve the resolution of the conflicts between coastal uses (in terms of stress produced by anthropic activities) and sensitivity areas.

  10. NEAR-REAL-TIME MEASUREMENT OF TRACE VOLATILE ORGANIC COMPOUNDS FROM COMBUSTION PROCESSES USING AN ON-LINE GAS CHROMATOGRAPH

    EPA Science Inventory

    The U.S. EPA's current regulatory approach for combustion and incineration sources emphasizes the use of real-time continuous emission monitors (CEMs) for particulate, Metals, and volatile, semivolatile, and of nonvolatile organic compounds to monitor source emissions. Currently...

  11. Techniques for forced response involving discrete nonlinearities. I - Theory. II - Applications

    NASA Astrophysics Data System (ADS)

    Avitabile, Peter; Callahan, John O.

    Several new techniques developed for the forced response analysis of systems containing discrete nonlinear connection elements are presented and compared to the traditional methods. In particular, the techniques examined are the Equivalent Reduced Model Technique (ERMT), Modal Modification Response Technique (MMRT), and Component Element Method (CEM). The general theory of the techniques is presented, and applications are discussed with particular reference to the beam nonlinear system model using ERMT, MMRT, and CEM; frame nonlinear response using the three techniques; and comparison of the results obtained by using the ERMT, MMRT, and CEM models.

  12. 77 FR 1434 - Proposed Confidentiality Determinations for Data Elements Under the Mandatory Reporting of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-10

    .... EPA-HQ- OAR-2011-0028, by one of the following methods: Federal eRulemaking Portal: http://www... document. BAMM Best Available Monitoring Methods CAA Clean Air Act CEMS continuous emission monitoring... Methodology and Methodological Tier..... X Data Elements Reported for Periods of Missing Data X that are Not...

  13. Installation and certification of continuous VOC emissions monitoring systems for a steel mill sinter plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor, K.L.; Macak, J.J. III; Cioffi, J.

    1999-07-01

    The counties of Lake, Porter, and LaPorte in Northwest Indiana are classified as severe non-attainment for the ozone National Ambient Air Quality Standard (NAAQS). In response to the non-attainment problem, the Indiana Department of Environmental Management (IDEM) promulgated a number of regulations over the last several years. One of these rules requires steel mills with sinter plants to control and continuously monitor volatile organic compound (VOC) emissions from the facilities. One of the accepted compliance methods is to install and certify Continuous Emission Monitoring Systems (CEMS) to monitor VOC emissions and volumetric flow rate in order to generate a VOCmore » emission number in units of pounds per hour. Compliance with the regulation also requires that the sinter plants accurately monitor sinter production in order to determine compliance during the winter months, when the limits are based on pounds of VOC emissions per ton of sinter produced.« less

  14. Water quality monitoring in a bathing area of Civitavecchia (Latium, Italy) using Chromophoric Dissolved Organic Matter (CDOM) as a tracer of faecal contamination

    NASA Astrophysics Data System (ADS)

    Madonia, Alice; Bonamano, Simone; Caruso, Gabriella; Stefani', Chiara; Consalvi, Natalizia; Piermattei, Viviana; Zappalà, Giuseppe; Marcelli, Marco

    2017-04-01

    Coastal urban bathing areas are often affected by events of faecal contamination, caused by the discharge of untreated wastewaters during the bathing season that can increase the risk for public health. Monitoring the quality of recreational waters is still closely linked to time-consuming seawater sampling and laboratory analysis, not allowing promptly management interventions. To face this issue, the European environmental policies strongly promote the development of coastal observing systems, above all in the Southern European Seas (SES). Chromophoric Dissolved Organic Matter (CDOM) has been increasingly used as a tracer of bacterial loads, since wastewaters are characterized by a large amount of organic compounds. The aim of this work was to study the relation between CDOM and Escherichia coli abundance, giving relevance to bacterial physiological state detected using both the standard culture method and the innovative fluorescent antibody technique. Attention has been paid also on the expression of extracellular enzymatic activity by the total microbial community to explore the role of bacteria in the decomposition processes of dissolved organic matter. Data were collected during summer 2015 and 2016 in a bathing area of Civitavecchia at increasing distances from the discharge point. The results confirm the usefulness of CDOM measurements as a proxy of faecal pollution in bathing areas. In this perspective, the low-cost stand-alone systems equipped with CDOM fluorescence sensors developed by the Laboratory of Experimental Oceanology and Marine Ecology (Tuscia University) (Marcelli et al., 2014) could allow the continous monitoring of water quality, increasing the capabilities of the Civitavecchia Coastal Environmental Monitoring System (C-CEMS) in the analysis of pollution events. Thanks to the integration of in situ fixed stations, high-resolution satellites imagery and numerical models, C-CEMS provides a management tool to support the stakeholders for timely decision making (Bonamano et al., 2016).

  15. 40 CFR 63.2163 - If I monitor fermenter exhaust, what are my monitoring installation, operation, and maintenance...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...-accuracy test PS 8 requires. (3) If you continuously monitor VOC emissions using gas chromatography, you... percent of the span value (or more than 10 percent of the calibration gas value if your CEMS is a gas... calibration drift exceeds 5 percent of the span value (or more than 20 percent of the calibration gas value...

  16. 40 CFR 63.2163 - If I monitor fermenter exhaust, what are my monitoring installation, operation, and maintenance...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...-accuracy test PS 8 requires. (3) If you continuously monitor VOC emissions using gas chromatography, you... percent of the span value (or more than 10 percent of the calibration gas value if your CEMS is a gas... calibration drift exceeds 5 percent of the span value (or more than 20 percent of the calibration gas value...

  17. Modern nature and climate changes in Siberia: new methods and results of analysis of instrumented observations

    NASA Astrophysics Data System (ADS)

    Kabanov, Mikhail V.

    2002-02-01

    Peculiarity of nature and climate changes in middle latitudes of the Northern Hemisphere and in Siberia is that the temporal variability of meteorological quantities here has a wide range and their spatial variability has a complicated zone structure. Therefore, regional monitoring of modern nature and climate changes in Siberia is of scientific interest from the viewpoint of the global changes observed. Another Siberian peculiarity is associated with the fact that there are many unique objects that have global importance both as natural complexes (boreal forests, water- bog systems, Baikal lake, etc.) And as technogenic objects (oil and gas production, coal mining, metallurgy, transport, etc.). Therefore monitoring and modeling of regional nature and climate changes in Siberia have great practical importance, which is underestimated now, for industrial development of Siberia. Taking into account the above peculiarities and tendencies on investigation of global and regional environmental and climate changes, the multidisciplinary project on Climate and Ecological Monitoring of Siberia (CEMS) was accepted to the research and development program Sibir' since 1993. To realize this project, the Climate and Ecological Observatory was established in Tomsk at the Institute for Optical Monitoring (IOM) SB RAS. At the present time the stations (the basic and background ones) of this observatory are in a progress and theory and instruments for monitoring are being developed as well. In this paper we discuss some results obtained in the framework of CEMS project that were partially published in the monographs, in scientific journals, and will be published in the Proceedings of the 8th Joint International Symposium on Atmospheric and Ocean Optics and Atmosphere Physics. This review has a purpose not only to discuss the obtained regularities but also to formulate scientific and technical tasks for further investigations into the regional changes of technogenic, natural, and climate systems.

  18. 8760-Based Method for Representing Variable Generation Capacity Value in Capacity Expansion Models: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frew, Bethany A; Cole, Wesley J; Sun, Yinong

    Capacity expansion models (CEMs) are widely used to evaluate the least-cost portfolio of electricity generators, transmission, and storage needed to reliably serve demand over the evolution of many years or decades. Various CEM formulations are used to evaluate systems ranging in scale from states or utility service territories to national or multi-national systems. CEMs can be computationally complex, and to achieve acceptable solve times, key parameters are often estimated using simplified methods. In this paper, we focus on two of these key parameters associated with the integration of variable generation (VG) resources: capacity value and curtailment. We first discuss commonmore » modeling simplifications used in CEMs to estimate capacity value and curtailment, many of which are based on a representative subset of hours that can miss important tail events or which require assumptions about the load and resource distributions that may not match actual distributions. We then present an alternate approach that captures key elements of chronological operation over all hours of the year without the computationally intensive economic dispatch optimization typically employed within more detailed operational models. The updated methodology characterizes the (1) contribution of VG to system capacity during high load and net load hours, (2) the curtailment level of VG, and (3) the potential reductions in curtailments enabled through deployment of storage and more flexible operation of select thermal generators. We apply this alternate methodology to an existing CEM, the Regional Energy Deployment System (ReEDS). Results demonstrate that this alternate approach provides more accurate estimates of capacity value and curtailments by explicitly capturing system interactions across all hours of the year. This approach could be applied more broadly to CEMs at many different scales where hourly resource and load data is available, greatly improving the representation of challenges associate with integration of variable generation resources.« less

  19. 40 CFR 98.164 - Monitoring and QA/QC requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Fossil fuel consumption, when, pursuant to § 98.33(e), the owner or operator of a unit that uses CEMS to quantify CO2 emissions and that combusts both fossil and biogenic fuels separately reports the biogenic...

  20. 40 CFR 63.5545 - What are my monitoring installation, operation, and maintenance requirements?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... measure organic HAP emissions; and (iv) PS-15 of 40 CFR part 60, appendix B, for CEMS that use Fourier transform infrared spectroscopy to measure organic HAP emissions. (2) You must conduct a performance...

  1. A small, lightweight multipollutant sensor system for ground ...

    EPA Pesticide Factsheets

    Characterizing highly dynamic, transient, and vertically lofted emissions from open area sources poses unique measurement challenges. This study developed and applied a multipollutant sensor and integrated sampler system for use on mobile applications including tethered balloons (aerostats) and unmanned aerial vehicles (UAVs). The system is particularly applicable to open area sources, such as forest fires, due to its light weight (3.5 kg), compact size (6.75 L), and internal power supply. The sensor system, termed “Kolibri”, consists of sensors measuring CO2 and CO, and samplers for particulate matter (PM) and volatile organic compounds (VOCs). The Kolibri is controlled by a microcontroller which can record and transfer data in real time through a radio module. Selection of the sensors was based on laboratory testing for accuracy, response delay and recovery, cross-sensitivity, and precision. The Kolibri was compared against rack-mounted continuous emissions monitoring system (CEMs) and another mobile sampling instrument (the “Flyer”) that has been used in over ten open area pollutant sampling events. Our results showed that the time series of CO, CO2, and PM2.5 concentrations measured by the Kolibri agreed well with those from the CEMs and the Flyer, with a laboratory-tested percentage error of 4.9%, 3%, and 5.8%, respectively. The VOC emission factors obtained using the Kolibri were consistent with existing literature values that relate concentration

  2. Capacity expansion model of wind power generation based on ELCC

    NASA Astrophysics Data System (ADS)

    Yuan, Bo; Zong, Jin; Wu, Shengyu

    2018-02-01

    Capacity expansion is an indispensable prerequisite for power system planning and construction. A reasonable, efficient and accurate capacity expansion model (CEM) is crucial to power system planning. In most current CEMs, the capacity of wind power generation is considered as boundary conditions instead of decision variables, which may lead to curtailment or over construction of flexible resource, especially at a high renewable energy penetration scenario. This paper proposed a wind power generation capacity value(CV) calculation method based on effective load-carrying capability, and a CEM that co-optimizes wind power generation and conventional power sources. Wind power generation is considered as decision variable in this model, and the model can accurately reflect the uncertainty nature of wind power.

  3. Closed Environment Module - modularization and extension of the V-HAB

    NASA Astrophysics Data System (ADS)

    Plötner, Peter; Czupalla, M. Markus; Zhukov, Anton

    2012-07-01

    The `Virtual Habitat' (V-HAB), is a Life Support System (LSS) simulation, created to provide the possibility for dynamic simulation of LSS for future human spaceflight missions. V-HAB creates the option to optimize LSS during early design phases. Furthermore, it allows simulating e.g. worst case scenarios which cannot be tested in reality. In a nutshell the tool allows the testing of LSS robustness by means of computer simulations. V-HAB is a modular simulation consisting of a: Closed Environment Module (CEM) Crew Module Biological Module Physio-Chemical Module The focus of the paper will be the Closed Environment Module (CEM) which is the core of V-HAB. The main function of the CEM is the embedding of all modules in the entire simulation and the control of the LSS. The CEM includes the possibility to simulate an arbitrary number of compartments and tanks with the interaction between connected compartments. Furthermore, a control program to actuate the LSS Technologies was implemented in the CEM, and is also introduced. In this paper the capabilities of the CEM are introduced based on selected test cases. In particular the following capabilities are demonstrated: Supply Leakage ON/OFF controller Power management Un-/docking Controller for tanks with maximum filling degree The CEM of the V-HAB simulation was verified by simulating the Atmosphere Revitalization part of the ISS and comparing it to actual measurement data. The results of this analysis are also presented in the paper.

  4. An instrumental electrode model for solving EIT forward problems.

    PubMed

    Zhang, Weida; Li, David

    2014-10-01

    An instrumental electrode model (IEM) capable of describing the performance of electrical impedance tomography (EIT) systems in the MHz frequency range has been proposed. Compared with the commonly used Complete Electrode Model (CEM), which assumes ideal front-end interfaces, the proposed model considers the effects of non-ideal components in the front-end circuits. This introduces an extra boundary condition in the forward model and offers a more accurate modelling for EIT systems. We have demonstrated its performance using simple geometry structures and compared the results with the CEM and full Maxwell methods. The IEM can provide a significantly more accurate approximation than the CEM in the MHz frequency range, where the full Maxwell methods are favoured over the quasi-static approximation. The improved electrode model will facilitate the future characterization and front-end design of real-world EIT systems.

  5. Advanced Boundary Electrode Modeling for tES and Parallel tES/EEG.

    PubMed

    Pursiainen, Sampsa; Agsten, Britte; Wagner, Sven; Wolters, Carsten H

    2018-01-01

    This paper explores advanced electrode modeling in the context of separate and parallel transcranial electrical stimulation (tES) and electroencephalography (EEG) measurements. We focus on boundary condition-based approaches that do not necessitate adding auxiliary elements, e.g., sponges, to the computational domain. In particular, we investigate the complete electrode model (CEM) which incorporates a detailed description of the skin-electrode interface including its contact surface, impedance, and normal current distribution. The CEM can be applied for both tES and EEG electrodes which are advantageous when a parallel system is used. In comparison to the CEM, we test two important reduced approaches: the gap model (GAP) and the point electrode model (PEM). We aim to find out the differences of these approaches for a realistic numerical setting based on the stimulation of the auditory cortex. The results obtained suggest, among other things, that GAP and GAP/PEM are sufficiently accurate for the practical application of tES and parallel tES/EEG, respectively. Differences between CEM and GAP were observed mainly in the skin compartment, where only CEM explains the heating effects characteristic to tES.

  6. Safety and Effectiveness of Highly Active Antiretroviral Therapy in Treatment-Naïve HIV Patients: Preliminary Findings of a Cohort Event Monitoring Study in Belarus.

    PubMed

    Setkina, Svetlana; Dotsenko, Marina; Bondar, Sviatlana; Charnysh, Iryna; Kuchko, Alla; Kaznacheeva, Alena; Kozorez, Elena; Dodaleva, Alena; Rossa, Natalia

    2015-04-01

    Antiretroviral drugs have well-documented evidence-based favorable benefit-risk ratios. Although various studies have investigated and characterized the safety profile of antiretroviral medicines, there are a limited number of studies evaluating the safety of first-line antiretroviral therapy (ART) in patients with a specific co-morbidity. A cohort event monitoring (CEM) study of the safety and effectiveness of antiretroviral medicines in a target population that has a significant level of co-morbidities (chronic infectious diseases, peripheral blood cytopenias) was implemented. The aim was to evaluate the safety profile of the highly active ART (HAART) in the target population and subpopulations with risk factors, to optimize the monitoring and decision-making procedure for subgroups of patients with specific types of co-morbidity, and to implement a more vigilant approach to therapy management in risk groups of patients. Prospective observational CEM was implemented among HAART-naïve HIV-positive patients at four clinical sites from December 2012. Eligible patients were those starting first-line HAART. Close medical supervision of all enrolled patients, with regular clinical and laboratory monitoring, was provided by healthcare professionals within 1 year after commencement of therapy. Standardized forms were used for data collection on initial and subsequent visits. All objective or subjective deviations in condition (events) were assessed for a causal relationship with ART, and for severity, seriousness, reversibility, preventability, and pre-existing risk factors in the case of adverse drug reactions (ADRs). A total of 518 HAART-naïve HIV-positive patients were enrolled in the CEM study. Of these patients, 65% (337) experienced one or several ADRs related to one or more components of HAART. Most of the ADRs reported were non-serious, expected, common (very common), transient (correctable), or reversible. The most common were hematotoxic, hepatotoxic, and neurotoxic adverse reactions. In several cases, some types of toxicities, associated with zidovudine, efavirenz, and nevirapine, had a high level of severity, necessitating hospitalization and drug regimen or single-agent substitution. Severe cases of hematological, hepatobiliary, and psychiatric toxicities were associated with pre-existing risk factors. CEM is an effective tool for safety and effectiveness monitoring and could be successfully implemented for intensive study of important safety issues and for overcoming knowledge gaps regarding safety. In order to achieve a favorable benefit-risk ratio for HAART in the specific sections of the population with pre-existing risk factors for development of ART toxicities, more vigilant consideration and careful assessment before therapy is commenced and further regular monitoring of key laboratory parameters is required.

  7. Extended Community: An Oral History of the Community Environmental Monitoring Program (CEMP), 1989 - 2003

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Susan DeSilva

    2004-07-01

    Studying the Community Environmental Monitoring Program (CEMP) provides a unique opportunity to trace a concept created by two nuclear industry originators from inception, as it transitioned through several stewardship agencies, to management by a non-profit organization. This transition is informed not only by changes over two decades in the views of the general populace toward nuclear testing but also by changing political climates and public policies. Several parallel histories accompanied the development of the CEMP: an administrative history, an environmental history, and a history of changing public perception of not only nuclear testing, but other activities involving radiation such asmore » waste transportation, as well. Although vital, those histories will be provided only as background to the subject of this study, the oral histories gathered in this project. The oral histories collected open a window into the nuclear testing history of Nevada and Utah that has not heretofore been opened. The nuclear industry has generated a great deal of positive and negative reaction since its inception. The CEMP emerged with specific objectives. It was designed to provide information to potential downwind communities and counter negative perceptions by creating more community involvement and education about the testing. The current objectives of the program are to: (1) Manage and maintain the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO) offsite monitoring program including 26 radiation and environmental monitoring stations with associated equipment. Provide air sample collection and analysis, radiological and meteorological data collection, interpretation and reporting. (2) Facilitate independent operation of radiological monitoring stations and data verification by private citizens living in communities in proximity to the Nevada Test Site (NTS). (3) Hire and initiate training of local citizens to serve as Community Environmental Monitors (CEMs) in designated communities. (4) Provide relevant training by qualified instructors to the CEMs as necessary. (5) Assist and manage CEMs in accomplishing their duties, and ensure that contracts and paychecks are issued on schedule. (6) Provide CEMs and Emeriti monthly materials to facilitate public awareness. This project explores how those objectives evolved over time with changes in the nuclear testing program. How similar are today's objectives to those originally established for the program? Do those objectives reflect a changing political landscape as well as changes in testing needs? Those questions and more will be addressed as we follow the program from its inception, through earlier versions administered first by the Public Health Service (PHS), then by the U.S. Environmental Protection Agency (EPA) to the current administrator, the Desert Research Institute (DRI).« less

  8. 8760-Based Method for Representing Variable Generation Capacity Value in Capacity Expansion Models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frew, Bethany A

    Capacity expansion models (CEMs) are widely used to evaluate the least-cost portfolio of electricity generators, transmission, and storage needed to reliably serve load over many years or decades. CEMs can be computationally complex and are often forced to estimate key parameters using simplified methods to achieve acceptable solve times or for other reasons. In this paper, we discuss one of these parameters -- capacity value (CV). We first provide a high-level motivation for and overview of CV. We next describe existing modeling simplifications and an alternate approach for estimating CV that utilizes hourly '8760' data of load and VG resources.more » We then apply this 8760 method to an established CEM, the National Renewable Energy Laboratory's (NREL's) Regional Energy Deployment System (ReEDS) model (Eurek et al. 2016). While this alternative approach for CV is not itself novel, it contributes to the broader CEM community by (1) demonstrating how a simplified 8760 hourly method, which can be easily implemented in other power sector models when data is available, more accurately captures CV trends than a statistical method within the ReEDS CEM, and (2) providing a flexible modeling framework from which other 8760-based system elements (e.g., demand response, storage, and transmission) can be added to further capture important dynamic interactions, such as curtailment.« less

  9. Microbial desalination cell with sulfonated sodium poly(ether ether ketone) as cation exchange membranes for enhancing power generation and salt reduction.

    PubMed

    Moruno, Francisco Lopez; Rubio, Juan E; Atanassov, Plamen; Cerrato, José M; Arges, Christopher G; Santoro, Carlo

    2018-06-01

    Microbial desalination cell (MDC) is a bioelectrochemical system capable of oxidizing organics, generating electricity, while reducing the salinity content of brine streams. As it is designed, anion and cation exchange membranes play an important role on the selective removal of ions from the desalination chamber. In this work, sulfonated sodium (Na + ) poly(ether ether ketone) (SPEEK) cation exchange membranes (CEM) were tested in combination with quaternary ammonium chloride poly(2,6-dimethyl 1,4-phenylene oxide) (QAPPO) anion exchange membrane (AEM). Non-patterned and patterned (varying topographical features) CEMs were investigated and assessed in this work. The results were contrasted against a commercially available CEM. This work used real seawater from the Pacific Ocean in the desalination chamber. The results displayed a high desalination rate and power generation for all the membranes, with a maximum of 78.6±2.0% in salinity reduction and 235±7mWm -2 in power generation for the MDCs with the SPEEK CEM. Desalination rate and power generation achieved are higher with synthesized SPEEK membranes when compared with an available commercial CEM. An optimized combination of these types of membranes substantially improves the performances of MDC, making the system more suitable for real applications. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  10. Effect of the type of ion exchange membrane on performance, ion transport, and pH in biocatalyzed electrolysis of wastewater.

    PubMed

    Rozendal, R A; Sleutels, T H J A; Hamelers, H V M; Buisman, C J N

    2008-01-01

    Previous studies have shown that the application of cation exchange membranes (CEMs) in bioelectrochemical systems running on wastewater can cause operational problems. In this paper the effect of alternative types of ion exchange membrane is studied in biocatalyzed electrolysis cells. Four types of ion exchange membranes are used: (i) a CEM, (ii) an anion exchange membrane (AEM), (iii) a bipolar membrane (BPM), and (iv) a charge mosaic membrane (CMM). With respect to the electrochemical performance of the four biocatalyzed electrolysis configurations, the ion exchange membranes are rated in the order AEM > CEM > CMM > BPM. However, with respect to the transport numbers for protons and/or hydroxyl ions (t(H/OH)) and the ability to prevent pH increase in the cathode chamber, the ion exchange membranes are rated in the order BPM > AEM > CMM > CEM.

  11. 40 CFR Table 7 to Subpart Dddd of... - Continuous Compliance With the Compliance Options and Operating Requirements

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... requirements in Table 2 of this subpart based on THC CEMS data Collecting and recording the THC monitoring data... block average THC concentration in the exhaust gases less than or equal to the THC concentration...

  12. 40 CFR Table 7 to Subpart Dddd of... - Continuous Compliance With the Compliance Options and Operating Requirements

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... requirements in Table 2 of this subpart based on THC CEMS data Collecting and recording the THC monitoring data... block average THC concentration in the exhaust gases less than or equal to the THC concentration...

  13. 40 CFR Table 7 to Subpart Dddd of... - Continuous Compliance With the Compliance Options and Operating Requirements

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... requirements in Table 2 of this subpart based on THC CEMS data Collecting and recording the THC monitoring data... block average THC concentration in the exhaust gases less than or equal to the THC concentration...

  14. Comparison of Conjugate Gradient Density Matrix Search and Chebyshev Expansion Methods for Avoiding Diagonalization in Large-Scale Electronic Structure Calculations

    NASA Technical Reports Server (NTRS)

    Bates, Kevin R.; Daniels, Andrew D.; Scuseria, Gustavo E.

    1998-01-01

    We report a comparison of two linear-scaling methods which avoid the diagonalization bottleneck of traditional electronic structure algorithms. The Chebyshev expansion method (CEM) is implemented for carbon tight-binding calculations of large systems and its memory and timing requirements compared to those of our previously implemented conjugate gradient density matrix search (CG-DMS). Benchmark calculations are carried out on icosahedral fullerenes from C60 to C8640 and the linear scaling memory and CPU requirements of the CEM demonstrated. We show that the CPU requisites of the CEM and CG-DMS are similar for calculations with comparable accuracy.

  15. Comparison of Mercury Measurement Methods Using Two Active Filter Measurement Methods and a Tekran Speciation Unit

    NASA Astrophysics Data System (ADS)

    Pierce, A.; Gustin, M. S.; Huang, J.; Heidecorn, K.

    2014-12-01

    Three active mercury (Hg) measurement methods were operated side by side at an urban site (University of Nevada, Reno College of Agriculture Greenhouse facility, elev. 1370 m) in Reno, and at a high elevation site (Peavine Peak, elev. 2515 m) adjacent to Reno from December 2013 to October 2014. A model 602 BetaPlus Teledyne Advanced Pollution Instrumentation (TAPI, San Diego, CA USA) particulate measurement system was used to collect particulate matter on a 47 mm diameter cation exchange membrane (CEM, PN# MSTGS3R Mustang S, Pall Corp. Port Washington, NY) at a rate of 16.7 lpm for 24 hours to four days. Particulate concentrations were calculated using beta attenuation across the filters (non-destructive to filter material); the CEM filters were then analyzed for total Hg on a Tekran Total Hg Analysis system (model 2600, Tekran Instruments Corp. Knoxville, TN, USA). Concurrently, samples were collected on an active Hg membrane system. The active Hg membrane system consisted of 3 CEM filters sampling at a rate of 1 lpm for one to two weeks. CEM filters were then analyzed on the Tekran 2600. A Tekran speciation unit (model 1130, 1135, 2537) was also in operation and ambient air samples were analyzed for gaseous elemental Hg (GEM), gaseous oxidized Hg (GOM), and particulate bound Hg (PBM). Both the 602 BetaPlus system and the active Hg membrane system should collect RM on the CEM filters. The active Hg membrane system most likely captures mainly GOM based on previous tests with the Teflon inlet setup that indicated there was high static electricity effective in removing particulate matter. Flow rate and length of measurement (24 hours vs. four days) affected the Hg concentrations on the 602 BetaPlus system. Based on these measurements we hypothesize that, due to the high flow rate, and therefore short retention time, the 602 BetaPlus only captured PBM. It is also possible that there was loss of Hg to inlet walls due to the longer inlet on the 602 BetaPlus system compared to the active Hg membrane system.

  16. RESULTS OF THE SEPTEMBER 1997 DOE/EPA DEMONSTRATION OF MULTIMETAL CONTINUOUS EMISSION MONITORING TECHNOLOGIES

    EPA Science Inventory

    In September 1997, the U.S. Department of Energy (DOE) and U.S. Environmental Protection Agency (EPA) co-sponsored a demonstration of several multimetal continuous emission monitos (CEMs). The demonstration, performed at the EPA National Risk Management Research Laboratory, Air P...

  17. 40 CFR 63.8 - Monitoring requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... operation requirements as follows: (i) All COMS shall complete a minimum of one cycle of sampling and analyzing for each successive 10-second period and one cycle of data recording for each successive 6-minute period. (ii) All CEMS for measuring emissions other than opacity shall complete a minimum of one cycle of...

  18. An integrated approach to manage coastal ecosystems and prevent marine pollution effects

    NASA Astrophysics Data System (ADS)

    Marcelli, Marco; Bonamano, Simone; Carli, Filippo Maria; Giovacchini, Monica; Madonia, Alice; Mancini, Emanuele; Molino, Chiara; Piermattei, Viviana; Manfredi Frattarelli, Francesco

    2016-04-01

    This work focuses an integrated approach based on Sea-Use-Map (SUM), backed by a permanent monitoring system (C-CEMS-Civitavecchia Coastal Environmental Monitoring System). This tool supports the management of the marine coastal area, contributing substantially to ecosystem benefits evaluation and to minimize pollution impacts. Within the Blue Growth strategy, the protection of marine ecosystems is considered a priority for the sustainable growth of marine and maritime sectors. To face this issue, the European MSP and MSFD directives (2014/89/EU; 2008/56/EC) strongly promote the adoption of an ecosystem-based approach, paying particular attention to the support of monitoring networks that use L-TER (long-term ecological research) observations and integrate multi-disciplinary data sets. Although not largely used in Europe yet, the Environmental Sensitivity Index (ESI), developed in 1979 by NOAA (and promoted by IMO in 2010), can be considered an excellent example of ecosystem-based approach to reduce the environmental consequences of an oil spill event in a coastal area. SUM is an ecosystem oriented cartographic tool specifically designed to support the sustainable management of the coastal areas, such as the selection of the best sites for the introduction of new uses or the identification of the coastal areas subjected to potential impacts. It also enables a rapid evaluation of the benefits produced by marine areas as well as of their anthropogenic disturbance. SUM integrates C-CEMS dataset, geomorphological and ecological features and knowledge on the coastal and maritime space uses. The SUM appliance allowed to obtain relevant operational results in the Civitavecchia coastal area (Latium, Italy), characterized by high variability of marine and coastal environments, historical heritage and affected by the presence of a big harbour, relevant industrial infrastructures, and touristic features. In particular, the valuation of marine ecosystem services based on benthic biocenosis as relevant spatial unit, and the ESI calculation for Civitavecchia coastal areas, are reported.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krishnan, Venkat; Cole, Wesley

    Power sector capacity expansion models (CEMs) have a broad range of spatial resolutions. This paper uses the Regional Energy Deployment System (ReEDS) model, a long-term national scale electric sector CEM, to evaluate the value of high spatial resolution for CEMs. ReEDS models the United States with 134 load balancing areas (BAs) and captures the variability in existing generation parameters, future technology costs, performance, and resource availability using very high spatial resolution data, especially for wind and solar modeled at 356 resource regions. In this paper we perform planning studies at three different spatial resolutions--native resolution (134 BAs), state-level, and NERCmore » region level--and evaluate how results change under different levels of spatial aggregation in terms of renewable capacity deployment and location, associated transmission builds, and system costs. The results are used to ascertain the value of high geographically resolved models in terms of their impact on relative competitiveness among renewable energy resources.« less

  20. Characterization of contact offenders and child exploitation material trafficking on five peer-to-peer networks.

    PubMed

    Bissias, George; Levine, Brian; Liberatore, Marc; Lynn, Brian; Moore, Juston; Wallach, Hanna; Wolak, Janis

    2016-02-01

    We provide detailed measurement of the illegal trade in child exploitation material (CEM, also known as child pornography) from mid-2011 through 2014 on five popular peer-to-peer (P2P) file sharing networks. We characterize several observations: counts of peers trafficking in CEM; the proportion of arrested traffickers that were identified during the investigation as committing contact sexual offenses against children; trends in the trafficking of sexual images of sadistic acts and infants or toddlers; the relationship between such content and contact offenders; and survival rates of CEM. In the 5 P2P networks we examined, we estimate there were recently about 840,000 unique installations per month of P2P programs sharing CEM worldwide. We estimate that about 3 in 10,000 Internet users worldwide were sharing CEM in a given month; rates vary per country. We found an overall month-to-month decline in trafficking of CEM during our study. By surveying law enforcement we determined that 9.5% of persons arrested for P2P-based CEM trafficking on the studied networks were identified during the investigation as having sexually offended against children offline. Rates per network varied, ranging from 8% of arrests for CEM trafficking on Gnutella to 21% on BitTorrent. Within BitTorrent, where law enforcement applied their own measure of content severity, the rate of contact offenses among peers sharing the most-severe CEM (29%) was higher than those sharing the least-severe CEM (15%). Although the persistence of CEM on the networks varied, it generally survived for long periods of time; e.g., BitTorrent CEM had a survival rate near 100%. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Transformation of standardized clinical models based on OWL technologies: from CEM to OpenEHR archetypes

    PubMed Central

    Legaz-García, María del Carmen; Menárguez-Tortosa, Marcos; Fernández-Breis, Jesualdo Tomás; Chute, Christopher G; Tao, Cui

    2015-01-01

    Introduction The semantic interoperability of electronic healthcare records (EHRs) systems is a major challenge in the medical informatics area. International initiatives pursue the use of semantically interoperable clinical models, and ontologies have frequently been used in semantic interoperability efforts. The objective of this paper is to propose a generic, ontology-based, flexible approach for supporting the automatic transformation of clinical models, which is illustrated for the transformation of Clinical Element Models (CEMs) into openEHR archetypes. Methods Our transformation method exploits the fact that the information models of the most relevant EHR specifications are available in the Web Ontology Language (OWL). The transformation approach is based on defining mappings between those ontological structures. We propose a way in which CEM entities can be transformed into openEHR by using transformation templates and OWL as common representation formalism. The transformation architecture exploits the reasoning and inferencing capabilities of OWL technologies. Results We have devised a generic, flexible approach for the transformation of clinical models, implemented for the unidirectional transformation from CEM to openEHR, a series of reusable transformation templates, a proof-of-concept implementation, and a set of openEHR archetypes that validate the methodological approach. Conclusions We have been able to transform CEM into archetypes in an automatic, flexible, reusable transformation approach that could be extended to other clinical model specifications. We exploit the potential of OWL technologies for supporting the transformation process. We believe that our approach could be useful for international efforts in the area of semantic interoperability of EHR systems. PMID:25670753

  2. CE-MS for metabolomics: developments and applications in the period 2012-2014.

    PubMed

    Ramautar, Rawi; Somsen, Govert W; de Jong, Gerhardus J

    2015-01-01

    In the field of metabolomics, CE-MS is now regarded as a useful complementary analytical technique for the profiling of (highly) polar ionogenic metabolites in biological samples. Over the past few years, significant advancements have been made in CE-MS approaches for metabolic profiling studies. This paper, which is a follow-up of three previous review papers covering the years 2000-2012 [Electrophoresis 2009, 30, 276-291; Electrophoresis 2011, 32, 52-65; Electrophoresis 2013, 34, 86-98], provides an update of these developments covering the scientific literature from July 2012 to June 2014. Attention will be paid to novel interfacing techniques for coupling CE to MS and their implications for metabolomics studies. The potential of CEC-MS and MEKC-MS are also considered, and CE-MS systems for high-throughput metabolic profiling are discussed. The applicability of CE-MS for metabolomics studies is demonstrated by representative examples in the fields of biomedical, clinical, microbial, plant, environmental, and food metabolomics. An overview of recent CE-MS-based metabolomics studies is given in a table, which provides information on sample type and pretreatment, capillary coatings, and MS detection mode. Finally, general conclusions and perspectives are given. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Parameterizing the Variability and Uncertainty of Wind and Solar in CEMs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frew, Bethany

    We present current and improved methods for estimating the capacity value and curtailment impacts from variable generation (VG) in capacity expansion models (CEMs). The ideal calculation of these variability metrics is through an explicit co-optimized investment-dispatch model using multiple years of VG and load data. Because of data and computational limitations, existing CEMs typically approximate these metrics using a subset of all hours from a single year and/or using statistical methods, which often do not capture the tail-event impacts or the broader set of interactions between VG, storage, and conventional generators. In our proposed new methods, we use hourly generationmore » and load values across all hours of the year to characterize the (1) contribution of VG to system capacity during high load hours, (2) the curtailment level of VG, and (3) the reduction in VG curtailment due to storage and shutdown of select thermal generators. Using CEM model outputs from a preceding model solve period, we apply these methods to exogenously calculate capacity value and curtailment metrics for the subsequent model solve period. Preliminary results suggest that these hourly methods offer improved capacity value and curtailment representations of VG in the CEM from existing approximation methods without additional computational burdens.« less

  4. Can Curriculum-Embedded Measures Predict the Later Reading Achievement of Kindergarteners at Risk of Reading Disability?

    ERIC Educational Resources Information Center

    Oslund, Eric L.; Simmons, Deborah C.; Hagan-Burke, Shanna; Kwok, Oi-Man; Simmons, Leslie E.; Taylor, Aaron B.; Coyne, Michael D.

    2015-01-01

    This study examined the changing role and longitudinal predictive validity of curriculum-embedded progress-monitoring measures (CEMs ) for kindergarten students receiving Tier 2 intervention and identified as at risk of developing reading difficulties. Multiple measures were examined to determine whether they could predict comprehensive latent…

  5. 40 CFR 60.13 - Monitoring requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... operators of a CEMS installed in accordance with the provisions of this part, must check the zero (or low...) calibration drifts at least once each operating day in accordance with a written procedure. The zero and span must, at a minimum, be adjusted whenever either the 24-hour zero drift or the 24-hour span drift...

  6. 40 CFR 60.13 - Monitoring requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... operators of a CEMS installed in accordance with the provisions of this part, must check the zero (or low...) calibration drifts at least once daily in accordance with a written procedure. The zero and span must, as a minimum, be adjusted whenever either the 24-hour zero drift or the 24-hour span drift exceeds two times...

  7. 40 CFR 60.13 - Monitoring requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... operators of a CEMS installed in accordance with the provisions of this part, must check the zero (or low...) calibration drifts at least once daily in accordance with a written procedure. The zero and span must, as a minimum, be adjusted whenever either the 24-hour zero drift or the 24-hour span drift exceeds two times...

  8. 40 CFR 60.13 - Monitoring requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... operators of a CEMS installed in accordance with the provisions of this part, must check the zero (or low...) calibration drifts at least once daily in accordance with a written procedure. The zero and span must, as a minimum, be adjusted whenever either the 24-hour zero drift or the 24-hour span drift exceeds two times...

  9. AN ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) OF TWO CONTINUOUS EMISSION MONITORS (CEMS) FOR MEASURING AMMONIA EMISSIONS: SIEMENS AG LDS 3000, AND OPSIS AB LD500

    EPA Science Inventory

    The Environmental Technology Verification (ETV) Program, beginning as an initiative of the U.S. Environmental Protection Agency (EPA) in 1995, verifies the performance of commercially available, innovative technologies that can be used to measure environmental quality. The ETV ...

  10. 40 CFR 60.13 - Monitoring requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... operators of a CEMS installed in accordance with the provisions of this part, must check the zero (or low...) calibration drifts at least once daily in accordance with a written procedure. The zero and span must, as a minimum, be adjusted whenever either the 24-hour zero drift or the 24-hour span drift exceeds two times...

  11. A Smart Detection System Based on Specific Magnetic and Rolling Cycle Amplification Signal-Amplified Dual-Aptamers to Accurately Monitor Minimal Residual Diseases in Patients with T-ALL.

    PubMed

    Li, Xa; Zhou, Bo; Zhao, Zilong; Hu, Zixi; Zhou, Sufang; Yang, Nuo; Huang, Yong; Zhang, Zhenghua; Su, Jing; Lan, Dan; Qin, Xue; Meng, Jinyu; Zheng, Duo; He, Jian; Huang, Xianing; Zhao, Jing; Zhang, Zhiyong; Tan, Weihong; Lu, Xiaoling; Zhao, Yongxiang

    2016-12-01

    It is a major clinical challenge for clinicians how to early find out minimal residual diseases (MRD) of leukemia. Here, we developed a smart detection system for MRD involving magnetic aptamer sgc8 probe (M-sgc8 probe) to capture CEM cells and rolling cycle amplification probe (RCA-sgc8 probe) to initiate RCA, producing a single-stranded tandem repeated copy of the circular template. The DNA products were hybridized with molecular beacon to generate the amplified fluorescence signal. An in vitro model to mimic MRD was established to evaluate the sensitivity of the smart detection system. The smart detection system was used to detect MRD in patients with T-ALL peri-chemotherapy, which could not only specifically captured T-ALL cells, but also significantly amplified fluorescence signals on them. The sensitivity was 1/20,000. These results indicate that the smart detection system with high specificity and sensitivity could more efficiently monitor the progress of T-ALL peri-chemotherapy.

  12. A portable blood plasma clot micro-elastometry device based on resonant acoustic spectroscopy

    NASA Astrophysics Data System (ADS)

    Krebs, C. R.; Li, Ling; Wolberg, Alisa S.; Oldenburg, Amy L.

    2015-07-01

    Abnormal blood clot stiffness is an important indicator of coagulation disorders arising from a variety of cardiovascular diseases and drug treatments. Here, we present a portable instrument for elastometry of microliter volume blood samples based upon the principle of resonant acoustic spectroscopy, where a sample of well-defined dimensions exhibits a fundamental longitudinal resonance mode proportional to the square root of the Young's modulus. In contrast to commercial thromboelastography, the resonant acoustic method offers improved repeatability and accuracy due to the high signal-to-noise ratio of the resonant vibration. We review the measurement principles and the design of a magnetically actuated microbead force transducer applying between 23 pN and 6.7 nN, providing a wide dynamic range of elastic moduli (3 Pa-27 kPa) appropriate for measurement of clot elastic modulus (CEM). An automated and portable device, the CEMport, is introduced and implemented using a 2 nm resolution displacement sensor with demonstrated accuracy and precision of 3% and 2%, respectively, of CEM in biogels. Importantly, the small strains (<0.13%) and low strain rates (<1/s) employed by the CEMport maintain a linear stress-to-strain relationship which provides a perturbative measurement of the Young's modulus. Measurements of blood plasma CEM versus heparin concentration show that CEMport is sensitive to heparin levels below 0.050 U/ml, which suggests future applications in sensing heparin levels of post-surgical cardiopulmonary bypass patients. The portability, high accuracy, and high precision of this device enable new clinical and animal studies for associating CEM with blood coagulation disorders, potentially leading to improved diagnostics and therapeutic monitoring.

  13. A portable blood plasma clot micro-elastometry device based on resonant acoustic spectroscopy.

    PubMed

    Krebs, C R; Li, Ling; Wolberg, Alisa S; Oldenburg, Amy L

    2015-07-01

    Abnormal blood clot stiffness is an important indicator of coagulation disorders arising from a variety of cardiovascular diseases and drug treatments. Here, we present a portable instrument for elastometry of microliter volume blood samples based upon the principle of resonant acoustic spectroscopy, where a sample of well-defined dimensions exhibits a fundamental longitudinal resonance mode proportional to the square root of the Young's modulus. In contrast to commercial thromboelastography, the resonant acoustic method offers improved repeatability and accuracy due to the high signal-to-noise ratio of the resonant vibration. We review the measurement principles and the design of a magnetically actuated microbead force transducer applying between 23 pN and 6.7 nN, providing a wide dynamic range of elastic moduli (3 Pa-27 kPa) appropriate for measurement of clot elastic modulus (CEM). An automated and portable device, the CEMport, is introduced and implemented using a 2 nm resolution displacement sensor with demonstrated accuracy and precision of 3% and 2%, respectively, of CEM in biogels. Importantly, the small strains (<0.13%) and low strain rates (<1/s) employed by the CEMport maintain a linear stress-to-strain relationship which provides a perturbative measurement of the Young's modulus. Measurements of blood plasma CEM versus heparin concentration show that CEMport is sensitive to heparin levels below 0.050 U/ml, which suggests future applications in sensing heparin levels of post-surgical cardiopulmonary bypass patients. The portability, high accuracy, and high precision of this device enable new clinical and animal studies for associating CEM with blood coagulation disorders, potentially leading to improved diagnostics and therapeutic monitoring.

  14. The Effects of Alkaline pH on Microleakage of Mineral Trioxide Aggregate and Calcium Enriched Mixture Apical Plugs.

    PubMed

    Mirhadi, Hossein; Moazzami, Fariborz; Rangani Jahromi, Saeed; Safarzade, Sareh

    2016-03-01

    Alkaline pH can affect the physical and chemical properties and sealing ability of apical plug material. Calcium hydroxide is used as an intracanal medication to complete disinfection of root canals. It raises the pH of environment to alkaline value. The aim of this in vitro study was to evaluate and compare the effect of alkaline pH on the sealing ability of calcium-enriched mixture (CEM) cement and mineral trioxide aggregate (MTA) apical plugs. Seventy single-rooted human maxillary anterior teeth were randomly divided to two experimental groups for Angelus MTA and CEM cement (n=30) and two control groups (n=5). Each group was divided into two subgroups of 15 for neutral and alkaline pH, and 1 negative and 1 positive control groups of 5. The root canals were cleaned and shaped by using ProTaper rotary system (Dentsply Maillefer; Ballaigues, Switzerland) and the terminal 3mm of the roots were resected. Then, MTA and CEM cement were condensed in apical region with 3mm thickness. The samples were exposed to two environments with different pH values of 13 and 7.4. The leakage was assessed by using the fluid filtration technique at 1, 7, 14, 30 days intervals. Data were analyzed by the repeated measures MANOVA. There was no statistically significant difference in the rate of microleakage between neutral and alkaline pH of CEM cement and MTA (p> 0.05). The sealing ability of MTA in an alkaline pH of 13 was significantly less than CEM cement in this pH (p< 0.05). An environment with alkaline pH had no adverse effect on the sealing ability of MTA and CEM cement used as apical plugs. CEM cement had better sealing ability in alkaline pH.

  15. In vitro activity of solithromycin and its metabolites, CEM-214 and N-acetyl-CEM-101, against 100 clinical Ureaplasma spp. isolates compared with azithromycin.

    PubMed

    Furfaro, Lucy L; Spiller, O Brad; Keelan, Jeffrey A; Payne, Matthew S

    2015-09-01

    There is a strong association between vaginal and/or amniotic fluid Ureaplasma spp. colonisation and risk of preterm birth. The novel fluoroketolide antibiotic solithromycin (CEM-101) is active against Ureaplasma spp. in vitro. Evidence from ex vivo and in vivo models suggests that, unlike most macrolide antibiotics, solithromycin readily crosses the placenta. Solithromycin metabolism varies according to species; in pregnant sheep, the bioactive metabolites CEM-214 and N-acetyl-CEM-101 (NAc-CEM-101) have been shown to accumulate in the amniotic cavity following maternal solithromycin administration, potentially contributing to its antimicrobial effects. To determine the antimicrobial activity of these metabolites against Ureaplasma spp., the effects of solithromycin, CEM-214, NAc-CEM-101 and the comparator azithromycin were tested on a collection of 100 clinical Ureaplasma spp. isolates from the UK and Australia using a modified 96-well broth microdilution method. MIC90 values observed for the combined cohort were: solithromycin, 0.125 mg/L; CEM-214, 0.5mg/L; NAc-CEM-101, 0.5mg/L; and azithromycin, 2mg/L. Solithromycin showed 34-fold greater activity against Ureaplasma spp. isolates than azithromycin, whilst CEM-214 and NAc-CEM-101 possessed ca. 22% and 17% of the activity of solithromycin, respectively, significantly greater than that of azithromycin. One bacterial isolate showed resistance to azithromycin (MIC=16 mg/L) but had a much lower MIC for solithromycin (MIC=0.25mg/L). In conclusion, the metabolites of solithromycin had reduced, but still potent, activity against 100 clinical Ureaplasma spp. isolates in vitro. This may be important in some instances such as pregnancy, however studies to determine levels of the metabolites in these settings are required. Copyright © 2015 Elsevier B.V. and the International Society of Chemotherapy. All rights reserved.

  16. Transformation of standardized clinical models based on OWL technologies: from CEM to OpenEHR archetypes.

    PubMed

    Legaz-García, María del Carmen; Menárguez-Tortosa, Marcos; Fernández-Breis, Jesualdo Tomás; Chute, Christopher G; Tao, Cui

    2015-05-01

    The semantic interoperability of electronic healthcare records (EHRs) systems is a major challenge in the medical informatics area. International initiatives pursue the use of semantically interoperable clinical models, and ontologies have frequently been used in semantic interoperability efforts. The objective of this paper is to propose a generic, ontology-based, flexible approach for supporting the automatic transformation of clinical models, which is illustrated for the transformation of Clinical Element Models (CEMs) into openEHR archetypes. Our transformation method exploits the fact that the information models of the most relevant EHR specifications are available in the Web Ontology Language (OWL). The transformation approach is based on defining mappings between those ontological structures. We propose a way in which CEM entities can be transformed into openEHR by using transformation templates and OWL as common representation formalism. The transformation architecture exploits the reasoning and inferencing capabilities of OWL technologies. We have devised a generic, flexible approach for the transformation of clinical models, implemented for the unidirectional transformation from CEM to openEHR, a series of reusable transformation templates, a proof-of-concept implementation, and a set of openEHR archetypes that validate the methodological approach. We have been able to transform CEM into archetypes in an automatic, flexible, reusable transformation approach that could be extended to other clinical model specifications. We exploit the potential of OWL technologies for supporting the transformation process. We believe that our approach could be useful for international efforts in the area of semantic interoperability of EHR systems. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Numerical Technology for Large-Scale Computational Electromagnetics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sharpe, R; Champagne, N; White, D

    The key bottleneck of implicit computational electromagnetics tools for large complex geometries is the solution of the resulting linear system of equations. The goal of this effort was to research and develop critical numerical technology that alleviates this bottleneck for large-scale computational electromagnetics (CEM). The mathematical operators and numerical formulations used in this arena of CEM yield linear equations that are complex valued, unstructured, and indefinite. Also, simultaneously applying multiple mathematical modeling formulations to different portions of a complex problem (hybrid formulations) results in a mixed structure linear system, further increasing the computational difficulty. Typically, these hybrid linear systems aremore » solved using a direct solution method, which was acceptable for Cray-class machines but does not scale adequately for ASCI-class machines. Additionally, LLNL's previously existing linear solvers were not well suited for the linear systems that are created by hybrid implicit CEM codes. Hence, a new approach was required to make effective use of ASCI-class computing platforms and to enable the next generation design capabilities. Multiple approaches were investigated, including the latest sparse-direct methods developed by our ASCI collaborators. In addition, approaches that combine domain decomposition (or matrix partitioning) with general-purpose iterative methods and special purpose pre-conditioners were investigated. Special-purpose pre-conditioners that take advantage of the structure of the matrix were adapted and developed based on intimate knowledge of the matrix properties. Finally, new operator formulations were developed that radically improve the conditioning of the resulting linear systems thus greatly reducing solution time. The goal was to enable the solution of CEM problems that are 10 to 100 times larger than our previous capability.« less

  18. Applicability of the PEMS technique for simplified NO X monitoring on board ships

    NASA Astrophysics Data System (ADS)

    Cooper, D. A.; Ekström, M.

    The performance of a predictive emission monitoring system (PEMS) as a technique for NO x monitoring on medium speed marine diesel engines has been evaluated for 16 similar engines on four different ships. The PEMS function tested measured O 2 concentration in the exhaust gas, engine load, combustion air temperature and humidity, and barometric pressure to calculate the NO x concentration. Emission measurements were carried out by means of a conventional continuous emission monitoring system (CEMS) and the measured NO x concentrations were compared with those calculated by the PEMS function. For 11 of the 16 engines, the average error between measured and calculated NO x concentration was <10% of the calibration range (1725 ppm). In addition, 10 of the engines displayed correlation coefficients between measured and calculated NO x as 0.90 or higher. For two of the ships, the predicted NO x concentrations from all engines on board gave good agreement with those measured (2.6-4.7% and 2.6-8.0% average error). In other cases however, the performance of the PEMS function was poor e.g. the four engines of ship D showed average errors of 10.3-17.7%. Although similar engine models, fuel and load characteristics were compared in the tests, the specific NO x emissions at steady-state loads used varied from 12.6 up to 15.8 g k -1Wh corr. Although a single PEMS function may prove universal and adequate for calculating NO x emissions from similar engines on board the same ship, an engine specific PEMS function is recommended. The form of the PEMS function, i.e. using exhaust O 2 and engine load as inputs, is however likely to be applicable to most propeller-law diesel engines. Bearing in mind the performance criteria for using PEMS at land-based installations, the results from this study are promising. Viewed as a single data set of 56 h with 16 separate engine comparisons between CEMS and PEMS, the data set shows a relative accuracy of 14.5% i.e. within the 20% requirement of the US Environmental Protection Agency. In light of the increased interest and international guidelines for continuous NO x monitoring on board ships, the PEMS technique can offer a simple but cost-effective option.

  19. Evaluating the Value of High Spatial Resolution in National Capacity Expansion Models using ReEDS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krishnan, Venkat; Cole, Wesley

    2016-11-14

    Power sector capacity expansion models (CEMs) have a broad range of spatial resolutions. This paper uses the Regional Energy Deployment System (ReEDS) model, a long-term national scale electric sector CEM, to evaluate the value of high spatial resolution for CEMs. ReEDS models the United States with 134 load balancing areas (BAs) and captures the variability in existing generation parameters, future technology costs, performance, and resource availability using very high spatial resolution data, especially for wind and solar modeled at 356 resource regions. In this paper we perform planning studies at three different spatial resolutions--native resolution (134 BAs), state-level, and NERCmore » region level--and evaluate how results change under different levels of spatial aggregation in terms of renewable capacity deployment and location, associated transmission builds, and system costs. The results are used to ascertain the value of high geographically resolved models in terms of their impact on relative competitiveness among renewable energy resources.« less

  20. Separation and Analysis of Adherent and Non-Adherent Cancer Cells Using a Single-Cell Microarray Chip.

    PubMed

    Yamamura, Shohei; Yamada, Eriko; Kimura, Fukiko; Miyajima, Kumiko; Shigeto, Hajime

    2017-10-21

    A new single-cell microarray chip was designed and developed to separate and analyze single adherent and non-adherent cancer cells. The single-cell microarray chip is made of polystyrene with over 60,000 microchambers of 10 different size patterns (31-40 µm upper diameter, 11-20 µm lower diameter). A drop of suspension of adherent carcinoma (NCI-H1650) and non-adherent leukocyte (CCRF-CEM) cells was placed onto the chip, and single-cell occupancy of NCI-H1650 and CCRF-CEM was determined to be 79% and 84%, respectively. This was achieved by controlling the chip design and surface treatment. Analysis of protein expression in single NCI-H1650 and CCRF-CEM cells was performed on the single-cell microarray chip by multi-antibody staining. Additionally, with this system, we retrieved positive single cells from the microchambers by a micromanipulator. Thus, this system demonstrates the potential for easy and accurate separation and analysis of various types of single cells.

  1. Scanning Electron Microscopy and Energy-Dispersive X-Ray Microanalysis of Set CEM Cement after Application of Different Bleaching Agents.

    PubMed

    Samiei, Mohammad; Janani, Maryam; Vahdati, Amin; Alemzadeh, Yalda; Bahari, Mahmoud

    2017-01-01

    The present study evaluated the element distribution in completely set calcium-enriched mixture (CEM) cement after application of 35% carbamide peroxide, 40% hydrogen peroxide and sodium perborate as commercial bleaching agents using an energy-dispersive x-ray microanalysis (EDX) system. The surface structure was also observed using the scanning electron microscope (SEM). Twenty completely set CEM cement samples, measuring 4×4 mm 2 , were prepared in the present in vitro study and randomly divided into 4 groups based on the preparation technique as follows: the control group; 35% carbamide peroxide group in contact for 30-60 min for 4 times; 40% hydrogen peroxide group with contact time of 15-20 min for 3 times; and sodium perborate group, where the powder and liquid were mixed and placed on CEM cement surface 4 times. Data were analyzed at a significance level of 0.05 through the one Way ANOVA and Tukey's post hoc tests. EDX showed similar element distribution of oxygen, sodium, calcium and carbon in CEM cement with the use of carbamide peroxide and hydroxide peroxide; however, the distribution of silicon was different ( P <0.05). In addition, these bleaching agents resulted in significantly higher levels of oxygen and carbon ( P <0.05) and a lower level of calcium ( P <0.05) compared to the control group. SEM of the control group showed plate-like and globular structure. Sodium perborate was similar to control group due to its weak oxidizing properties. Globular structures and numerous woodpecker holes were observed on the even surface on the carbamide peroxide group. The mean elemental distribution of completely set CEM cement was different when exposed to sodium perborate, carbamide peroxide and hydrogen peroxide.

  2. Application of computational physics within Northrop

    NASA Technical Reports Server (NTRS)

    George, M. W.; Ling, R. T.; Mangus, J. F.; Thompkins, W. T.

    1987-01-01

    An overview of Northrop programs in computational physics is presented. These programs depend on access to today's supercomputers, such as the Numerical Aerodynamical Simulator (NAS), and future growth on the continuing evolution of computational engines. Descriptions here are concentrated on the following areas: computational fluid dynamics (CFD), computational electromagnetics (CEM), computer architectures, and expert systems. Current efforts and future directions in these areas are presented. The impact of advances in the CFD area is described, and parallels are drawn to analagous developments in CEM. The relationship between advances in these areas and the development of advances (parallel) architectures and expert systems is also presented.

  3. A New Objective Technique for Verifying Mesoscale Numerical Weather Prediction Models

    NASA Technical Reports Server (NTRS)

    Case, Jonathan L.; Manobianco, John; Lane, John E.; Immer, Christopher D.

    2003-01-01

    This report presents a new objective technique to verify predictions of the sea-breeze phenomenon over east-central Florida by the Regional Atmospheric Modeling System (RAMS) mesoscale numerical weather prediction (NWP) model. The Contour Error Map (CEM) technique identifies sea-breeze transition times in objectively-analyzed grids of observed and forecast wind, verifies the forecast sea-breeze transition times against the observed times, and computes the mean post-sea breeze wind direction and speed to compare the observed and forecast winds behind the sea-breeze front. The CEM technique is superior to traditional objective verification techniques and previously-used subjective verification methodologies because: It is automated, requiring little manual intervention, It accounts for both spatial and temporal scales and variations, It accurately identifies and verifies the sea-breeze transition times, and It provides verification contour maps and simple statistical parameters for easy interpretation. The CEM uses a parallel lowpass boxcar filter and a high-order bandpass filter to identify the sea-breeze transition times in the observed and model grid points. Once the transition times are identified, CEM fits a Gaussian histogram function to the actual histogram of transition time differences between the model and observations. The fitted parameters of the Gaussian function subsequently explain the timing bias and variance of the timing differences across the valid comparison domain. Once the transition times are all identified at each grid point, the CEM computes the mean wind direction and speed during the remainder of the day for all times and grid points after the sea-breeze transition time. The CEM technique performed quite well when compared to independent meteorological assessments of the sea-breeze transition times and results from a previously published subjective evaluation. The algorithm correctly identified a forecast or observed sea-breeze occurrence or absence 93% of the time during the two- month evaluation period from July and August 2000. Nearly all failures in CEM were the result of complex precipitation features (observed or forecast) that contaminated the wind field, resulting in a false identification of a sea-breeze transition. A qualitative comparison between the CEM timing errors and the subjectively determined observed and forecast transition times indicate that the algorithm performed very well overall. Most discrepancies between the CEM results and the subjective analysis were again caused by observed or forecast areas of precipitation that led to complex wind patterns. The CEM also failed on a day when the observed sea- breeze transition affected only a very small portion of the verification domain. Based on the results of CEM, the RAMS tended to predict the onset and movement of the sea-breeze transition too early and/or quickly. The domain-wide timing biases provided by CEM indicated an early bias on 30 out of 37 days when both an observed and forecast sea breeze occurred over the same portions of the analysis domain. These results are consistent with previous subjective verifications of the RAMS sea breeze predictions. A comparison of the mean post-sea breeze winds indicate that RAMS has a positive wind-speed bias for .all days, which is also consistent with the early bias in the sea-breeze transition time since the higher wind speeds resulted in a faster inland penetration of the sea breeze compared to reality.

  4. Potential of capillary electrophoresis mass spectrometry for the characterization and monitoring of amine-derivatized naphthenic acids from oil sands process-affected water.

    PubMed

    MacLennan, Matthew S; Tie, Cai; Kovalchik, Kevin; Peru, Kerry M; Zhang, Xinxiang; Headley, John V; Chen, David D Y

    2016-11-01

    Capillary electrophoresis coupled to mass spectrometry (CE-MS) was used for the analysis of naphthenic acid fraction compounds (NAFCs) of oil sands process-affected water (OSPW). A standard mixture of amine-derivatized naphthenic acids is injected directly onto the CE column and analyzed by CE-MS in less than 15min. Time of flight MS analysis (TOFMS), optimized for high molecular weight ions, showed NAFCs between 250 and 800m/z. With a quadrupole mass analyzer, only low-molecular weight NAFCs (between 100 and 450m/z) are visible under our experimental conditions. Derivatization of NAFCs consisted of two-step amidation reactions mediated by 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide (EDC), or mediated by a mixture of EDC and N-hydroxysuccinimide, in dimethyl sulfoxide, dichloromethane or ethyl acetate. The optimum background electrolyte composition was determined to be 30% (V/V) methanol in water and 2% (V/V) formic acid. NAFCs extracted from OSPW in the Athabasca oil sands region were used to demonstrate the feasibility of CE-MS for the analysis of NAFCs in environmental samples, showing that the labeled naphthenic acids are in the mass range of 350 to 1500m/z. Copyright © 2016. Published by Elsevier B.V.

  5. A portable blood plasma clot micro-elastometry device based on resonant acoustic spectroscopy

    PubMed Central

    Krebs, C. R.; Li, Ling; Wolberg, Alisa S.; Oldenburg, Amy L.

    2015-01-01

    Abnormal blood clot stiffness is an important indicator of coagulation disorders arising from a variety of cardiovascular diseases and drug treatments. Here, we present a portable instrument for elastometry of microliter volume blood samples based upon the principle of resonant acoustic spectroscopy, where a sample of well-defined dimensions exhibits a fundamental longitudinal resonance mode proportional to the square root of the Young’s modulus. In contrast to commercial thromboelastography, the resonant acoustic method offers improved repeatability and accuracy due to the high signal-to-noise ratio of the resonant vibration. We review the measurement principles and the design of a magnetically actuated microbead force transducer applying between 23 pN and 6.7 nN, providing a wide dynamic range of elastic moduli (3 Pa–27 kPa) appropriate for measurement of clot elastic modulus (CEM). An automated and portable device, the CEMport, is introduced and implemented using a 2 nm resolution displacement sensor with demonstrated accuracy and precision of 3% and 2%, respectively, of CEM in biogels. Importantly, the small strains (<0.13%) and low strain rates (<1/s) employed by the CEMport maintain a linear stress-to-strain relationship which provides a perturbative measurement of the Young’s modulus. Measurements of blood plasma CEM versus heparin concentration show that CEMport is sensitive to heparin levels below 0.050 U/ml, which suggests future applications in sensing heparin levels of post-surgical cardiopulmonary bypass patients. The portability, high accuracy, and high precision of this device enable new clinical and animal studies for associating CEM with blood coagulation disorders, potentially leading to improved diagnostics and therapeutic monitoring. PMID:26233406

  6. Mammal responses to the human footprint vary across species and stressors.

    PubMed

    Toews, Mary; Juanes, Francis; Burton, A Cole

    2018-07-01

    A rapidly expanding human footprint - comprised of anthropogenic land-use change and infrastructure - is profoundly affecting wildlife distributions worldwide. Cumulative effects management (CEM) is a regional approach that seeks to manage combined effects of the human footprint on biodiversity across large spatial scales. Challenges to implementing this approach include a lack of ecological data at large spatial scales, the high cost of monitoring multiple indicators, and the need to manage multiple footprints across industries. To inform development of effective CEM, we used large mammals as indicators to address the following questions: a) do species respond more strongly to individual footprint features or to cumulative effects (combined area of all footprint types, measured as total footprint), b) which features elicit the strongest responses across species, and c) are the direction of responses to footprint consistent? We used data from 12 years of snowtrack surveys (2001-2013) in the boreal forest of Alberta, coupled with regional footprint and landcover data, to develop generalized linear mixed-effects models relating the relative abundance of five boreal mammals [gray wolf (Canis lupus), Canada lynx (Lynx canadensis), coyote (Canis latrans), white-tailed deer (Odocoileus virginianus) and moose (Alces alces)] to individual and cumulative effects of the human footprint. We found that across species the strongest responses were to agriculture, roads, and young cutblocks (<10 years), suggesting these as potential priority stressors to address within CEM. Most species also responded to total footprint, indicating that in the absence of detailed information on individual features, this coarse measure can serve as an index of cumulative effects. There was high variability in direction and magnitude of responses across species, indicating that community-level responses are likely and should be considered within CEM planning. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. Endomicroscopy and electromyography of neuromuscular junctions in situ

    PubMed Central

    Brown, Rosalind; Dissanayake, Kosala N; Skehel, Paul A; Ribchester, Richard R

    2014-01-01

    Objective Electromyography (EMG) is used routinely to diagnose neuromuscular dysfunction in a wide range of peripheral neuropathies, myopathies, and neuromuscular degenerative diseases including motor neuron diseases such as amyotrophic lateral sclerosis (ALS). Definitive neurological diagnosis may also be indicated by the analysis of pathological neuromuscular innervation in motor-point biopsies. Our objective in this study was to preempt motor-point biopsy by combining live imaging with electrophysiological analysis of slow degeneration of neuromuscular junctions (NMJs) in vivo. Methods We combined conventional needle electromyography with fiber-optic confocal endomicroscopy (CEM), using an integrated hand-held, 1.5-mm-diameter probe. We utilized as a test bed, various axotomized muscles in the hind limbs of anaesthetized, double-homozygous thy1.2YFP16: WldS mice, which coexpress the Wallerian-degeneration Slow (WldS) protein and yellow fluorescent protein (YFP) in motor neurons. We also tested exogenous vital stains, including Alexa488-α-bungarotoxin; the styryl pyridinium dye 4-Di-2-Asp; and a GFP conjugate of botulinum toxin Type A heavy chain (GFP-HcBoNT/A). Results We show that an integrated EMG/CEM probe is effective in longitudinal evaluation of functional and morphological changes that take place over a 7-day period during axotomy-induced, slow neuromuscular synaptic degeneration. EMG amplitude declined in parallel with overt degeneration of motor nerve terminals. EMG/CEM was safe and effective when nerve terminals and motor endplates were selectively stained with vital dyes. Interpretation Our findings constitute proof-of-concept, based on live imaging in an animal model, that combining EMG/CEM may be useful as a minimally invasive precursor or alternative to motor-point biopsy in neurological diagnosis and for monitoring local administration of potential therapeutics. PMID:25540801

  8. Validation of the Aerosol Beam-Focused Laser-Induced Plasma Spectrometer (ABF-LIPS) for Metal Emission Characterization

    DTIC Science & Technology

    2010-03-01

    Reliable spiking of the airstream with metals proved to be a challenge . Based on reference method results, it is unclear whether delivery of the...etc that challenge the pollutant analyzer part of the CEMS (and as much of the whole system as possible), but which do not challenge the entire...calibration, when developed, will be acceptable as a procedure for determining RA. Such a procedure will involve challenging the entire CEMS, including the

  9. Parameters that affect parallel processing for computational electromagnetic simulation codes on high performance computing clusters

    NASA Astrophysics Data System (ADS)

    Moon, Hongsik

    What is the impact of multicore and associated advanced technologies on computational software for science? Most researchers and students have multicore laptops or desktops for their research and they need computing power to run computational software packages. Computing power was initially derived from Central Processing Unit (CPU) clock speed. That changed when increases in clock speed became constrained by power requirements. Chip manufacturers turned to multicore CPU architectures and associated technological advancements to create the CPUs for the future. Most software applications benefited by the increased computing power the same way that increases in clock speed helped applications run faster. However, for Computational ElectroMagnetics (CEM) software developers, this change was not an obvious benefit - it appeared to be a detriment. Developers were challenged to find a way to correctly utilize the advancements in hardware so that their codes could benefit. The solution was parallelization and this dissertation details the investigation to address these challenges. Prior to multicore CPUs, advanced computer technologies were compared with the performance using benchmark software and the metric was FLoting-point Operations Per Seconds (FLOPS) which indicates system performance for scientific applications that make heavy use of floating-point calculations. Is FLOPS an effective metric for parallelized CEM simulation tools on new multicore system? Parallel CEM software needs to be benchmarked not only by FLOPS but also by the performance of other parameters related to type and utilization of the hardware, such as CPU, Random Access Memory (RAM), hard disk, network, etc. The codes need to be optimized for more than just FLOPs and new parameters must be included in benchmarking. In this dissertation, the parallel CEM software named High Order Basis Based Integral Equation Solver (HOBBIES) is introduced. This code was developed to address the needs of the changing computer hardware platforms in order to provide fast, accurate and efficient solutions to large, complex electromagnetic problems. The research in this dissertation proves that the performance of parallel code is intimately related to the configuration of the computer hardware and can be maximized for different hardware platforms. To benchmark and optimize the performance of parallel CEM software, a variety of large, complex projects are created and executed on a variety of computer platforms. The computer platforms used in this research are detailed in this dissertation. The projects run as benchmarks are also described in detail and results are presented. The parameters that affect parallel CEM software on High Performance Computing Clusters (HPCC) are investigated. This research demonstrates methods to maximize the performance of parallel CEM software code.

  10. CE-MS for metabolomics: Developments and applications in the period 2014-2016.

    PubMed

    Ramautar, Rawi; Somsen, Govert W; de Jong, Gerhardus J

    2017-01-01

    CE-MS can be considered a useful analytical technique for the global profiling of (highly) polar and charged metabolites in various samples. Over the past few years, significant advancements have been made in CE-MS approaches for metabolomics studies. In this paper, which is a follow-up of a previous review paper covering the years 2012-2014 (Electrophoresis 2015, 36, 212-224), recent CE-MS strategies developed for metabolomics covering the literature from July 2014 to June 2016 are outlined. Attention will be paid to new CE-MS approaches for the profiling of anionic metabolites and the potential of SPE coupled to CE-MS is also demonstrated. Representative examples illustrate the applicability of CE-MS in the fields of biomedical, clinical, microbial, plant, and food metabolomics. A complete overview of recent CE-MS-based metabolomics studies is given in a table, which provides information on sample type and pretreatment, capillary coatings, and MS detection mode. Finally, general conclusions and perspectives are given. © 2016 The Authors ELECTROPHORESIS Published by Wiley-VCH Verlag GmbH & Co. KGaA.

  11. 40 CFR 60.46c - Emission monitoring for sulfur dioxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... potential SO2 emission rate of the fuel combusted, and the span value of the SO2 CEMS at the outlet from the SO2 control device shall be 50 percent of the maximum estimated hourly potential SO2 emission rate of... estimated hourly potential SO2 emission rate of the fuel combusted. (d) As an alternative to operating a...

  12. 40 CFR 52.1220 - Identification of plan.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 49303 7017.1135 Applicability 03/01/99 08/10/11, 76 FR 49303 7017.1140 CEMS design requirements 03/01/99... 7017.1190 COMS design requirements 03/01/99 08/10/11, 76 FR 49303 7017.1200 COMS monitoring data 03/01.../01/99 08/10/11, 76 FR 49303 7017.2030 Performance test pretest requirements 03/01/99 08/10/11, 76 FR...

  13. 40 CFR 52.1220 - Identification of plan.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 49303 7017.1135 Applicability 03/01/99 08/10/11, 76 FR 49303 7017.1140 CEMS design requirements 03/01/99... 7017.1190 COMS design requirements 03/01/99 08/10/11, 76 FR 49303 7017.1200 COMS monitoring data 03/01.../01/99 08/10/11, 76 FR 49303 7017.2030 Performance test pretest requirements 03/01/99 08/10/11, 76 FR...

  14. 40 CFR 52.1220 - Identification of plan.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 49303 7017.1135 Applicability 03/01/99 08/10/11, 76 FR 49303 7017.1140 CEMS design requirements 03/01/99... 7017.1190 COMS design requirements 03/01/99 08/10/11, 76 FR 49303 7017.1200 COMS monitoring data 03/01.../01/99 08/10/11, 76 FR 49303 7017.2030 Performance test pretest requirements 03/01/99 08/10/11, 76 FR...

  15. 40 CFR 60.45 - Emissions and fuel monitoring.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... oil) with potential SO2 emissions rates of 26 ng/J (0.060 lb/MMBtu) or less and that does not use post... of a CEMS for NOX may be delayed until after the initial performance tests under § 60.8 have been conducted. If the owner or operator demonstrates during the performance test that emissions of NOX are less...

  16. 40 CFR 60.45 - Emissions and fuel monitoring.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... oil) with potential SO2 emissions rates of 26 ng/J (0.060 lb/MMBtu) or less and that does not use post... of a CEMS for NOX may be delayed until after the initial performance tests under § 60.8 have been conducted. If the owner or operator demonstrates during the performance test that emissions of NOX are less...

  17. 40 CFR 60.45 - Emissions and fuel monitoring.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... oil) with potential SO2 emissions rates of 26 ng/J (0.060 lb/MMBtu) or less and that does not use post... of a CEMS for NOX may be delayed until after the initial performance tests under § 60.8 have been conducted. If the owner or operator demonstrates during the performance test that emissions of NOX are less...

  18. Multiband tissue classification for ultrasonic transmission tomography using spectral profile detection

    NASA Astrophysics Data System (ADS)

    Jeong, Jeong-Won; Kim, Tae-Seong; Shin, Dae-Chul; Do, Synho; Marmarelis, Vasilis Z.

    2004-04-01

    Recently it was shown that soft tissue can be differentiated with spectral unmixing and detection methods that utilize multi-band information obtained from a High-Resolution Ultrasonic Transmission Tomography (HUTT) system. In this study, we focus on tissue differentiation using the spectral target detection method based on Constrained Energy Minimization (CEM). We have developed a new tissue differentiation method called "CEM filter bank". Statistical inference on the output of each CEM filter of a filter bank is used to make a decision based on the maximum statistical significance rather than the magnitude of each CEM filter output. We validate this method through 3-D inter/intra-phantom soft tissue classification where target profiles obtained from an arbitrary single slice are used for differentiation in multiple tomographic slices. Also spectral coherence between target and object profiles of an identical tissue at different slices and phantoms is evaluated by conventional cross-correlation analysis. The performance of the proposed classifier is assessed using Receiver Operating Characteristic (ROC) analysis. Finally we apply our method to classify tiny structures inside a beef kidney such as Styrofoam balls (~1mm), chicken tissue (~5mm), and vessel-duct structures.

  19. Performance of single chamber biocatalyzed electrolysis with different types of ion exchange membranes.

    PubMed

    Rozendal, René A; Hamelers, Hubertus V M; Molenkamp, Redmar J; Buisman, Cees J N

    2007-05-01

    In this paper hydrogen production through biocatalyzed electrolysis was studied for the first time in a single chamber configuration. Single chamber biocatalyzed electrolysis was tested in two configurations: (i) with a cation exchange membrane (CEM) and (ii) with an anion exchange membrane (AEM). Both configurations performed comparably and produced over 0.3 m3 H2/m3 reactor liquid volume/day at 1.0 V applied voltage (overall hydrogen efficiencies around 23%). Analysis of the water that permeated through the membrane revealed that a large part of potential losses in the system were associated with a pH gradient across the membrane (CEM DeltapH=6.4; AEM DeltapH=4.4). These pH gradient associated potential losses were lower in the AEM configuration (CEM 0.38 V; AEM 0.26 V) as a result of its alternative ion transport properties. This benefit of the AEM, however, was counteracted by the higher cathode overpotentials occurring in the AEM configuration (CEM 0.12 V at 2.39 A/m2; AEM 0.27 V at 2.15 A/m2) as a result of a less effective electroless plating method for the AEM membrane electrode assembly (MEA).

  20. Development of the CSI phase-3 evolutionary model testbed

    NASA Technical Reports Server (NTRS)

    Gronet, M. J.; Davis, D. A.; Tan, M. K.

    1994-01-01

    This report documents the development effort for the reconfiguration of the Controls-Structures Integration (CSI) Evolutionary Model (CEM) Phase-2 testbed into the CEM Phase-3 configuration. This step responds to the need to develop and test CSI technologies associated with typical planned earth science and remote sensing platforms. The primary objective of the CEM Phase-3 ground testbed is to simulate the overall on-orbit dynamic behavior of the EOS AM-1 spacecraft. Key elements of the objective include approximating the low-frequency appendage dynamic interaction of EOS AM-1, allowing for the changeout of components, and simulating the free-free on-orbit environment using an advanced suspension system. The fundamentals of appendage dynamic interaction are reviewed. A new version of the multiple scaling method is used to design the testbed to have the full-scale geometry and dynamics of the EOS AM-1 spacecraft, but at one-tenth the weight. The testbed design is discussed, along with the testing of the solar array, high gain antenna, and strut components. Analytical performance comparisons show that the CEM Phase-3 testbed simulates the EOS AM-1 spacecraft with good fidelity for the important parameters of interest.

  1. Ionization techniques in capillary electrophoresis-mass spectrometry: principles, design, and application.

    PubMed

    Hommerson, Paul; Khan, Amjad M; de Jong, Gerhardus J; Somsen, Govert W

    2011-01-01

    A major step forward in the development and application of capillary electrophoresis (CE) was its coupling to ESI-MS, first reported in 1987. More than two decades later, ESI has remained the principal ionization technique in CE-MS, but a number of other ionization techniques have also been implemented. In this review the state-of-the-art in the employment of soft ionization techniques for CE-MS is presented. First the fundamentals and general challenges of hyphenating conventional CE and microchip electrophoresis with MS are outlined. After elaborating on the characteristics and role of ESI, emphasis is put on alternative ionization techniques including sonic spray ionization (SSI), thermospray ionization (TSI), atmospheric pressure chemical ionization (APCI), atmospheric pressure photoionization (APPI), matrix-assisted laser desorption ionization (MALDI) and continuous-flow fast atom bombardment (CF-FAB). The principle of each ionization technique is outlined and the experimental set-ups of the CE-MS couplings are described. The strengths and limitations of each ionization technique with respect to CE-MS are discussed and the applicability of the various systems is illustrated by a number of typical examples. Copyright © 2011 Wiley Periodicals, Inc.

  2. Is There a Correlation Between Tensile Strength and Retrievability of Cemented Implant-Retained Crowns Using Artificial Aging?

    PubMed

    Mehl, Christian; Ali, Shurouk; El Bahra, Shadi; Harder, Sönke; Vollrath, Oliver; Kern, Matthias

    2016-01-01

    The main goal of this in-vitro study was to evaluate whether tensile strength and retrievability of cemented implant-retained crowns correlate when using artificial aging. A total of 128 crowns were fabricated from a cobalt-chromium alloy for 128 tapered titanium abutments (6 degrees taper, 4.3 mm diameter, 4 mm length, Camlog). The crowns were cemented with glass-ionomer (Ketac Cem, 3M) or resin cements (Multilink Implant, Telio CS Cem [Ivoclar Vivadent], Retrieve [Parkell]). Multilink Implant was used without priming. The experimental groups were subjected to either 37,500 thermal cycles between 5°C and 55°C, 1,200,000 chewing cycles, or a combination of both. Control groups were stored for 10 days in deionized water. The crowns were removed with a universal testing machine or a clinically used removal device (Coronaflex, KaVo). Data were statistically analyzed using nonparametrical tests. Retention values were recorded between 31 N and 362 N. Telio CS Cem showed the lowest retention values, followed by Retrieve, Ketac Cem, and Multilink Implant (P≤.0001). The number of removal attempts with the Coronaflex were not significantly different between the cements (P>.05). Thermal cycling and chewing simulation significantly influenced the retrieval of Retrieve Telio CS Cem, and Ketac Cem specimens (P≤.05). Only for Multilink Implant and Telio CS Cem correlations between removal with the universal testing machine and the Coronaflex could be revealed (P≤.0001). Ketac Cem and Multilink Implant (without silane) can be used for a semipermanent cementation. Retrieve and Telio CS Cem are recommendable for a temporary cementation.

  3. Understanding customer experience.

    PubMed

    Meyer, Christopher; Schwager, Andre

    2007-02-01

    Anyone who has signed up for cell phone service, attempted to claim a rebate, or navigated a call center has probably suffered from a company's apparent indifference to what should be its first concern: the customer experiences that culminate in either satisfaction or disappointment and defection. Customer experience is the subjective response customers have to direct or indirect contact with a company. It encompasses every aspect of an offering: customer care, advertising, packaging, features, ease of use, reliability. Customer experience is shaped by customers' expectations, which largely reflect previous experiences. Few CEOs would argue against the significance of customer experience or against measuring and analyzing it. But many don't appreciate how those activities differ from CRM or just how illuminating the data can be. For instance, the majority of the companies in a recent survey believed they have been providing "superior" experiences to customers, but most customers disagreed. The authors describe a customer experience management (CEM) process that involves three kinds of monitoring: past patterns (evaluating completed transactions), present patterns (tracking current relationships), and potential patterns (conducting inquiries in the hope of unveiling future opportunities). Data are collected at or about touch points through such methods as surveys, interviews, focus groups, and online forums. Companies need to involve every function in the effort, not just a single customer-facing group. The authors go on to illustrate how a cross-functional CEM system is created. With such a system, companies can discover which customers are prospects for growth and which require immediate intervention.

  4. Cost-engineering modeling to support rapid concept development of an advanced infrared satellite system

    NASA Astrophysics Data System (ADS)

    Bell, Kevin D.; Dafesh, Philip A.; Hsu, L. A.; Tsuda, A. S.

    1995-12-01

    Current architectural and design trade techniques often carry unaffordable alternatives late into the decision process. Early decisions made during the concept exploration and development (CE&D) phase will drive the cost of a program more than any other phase of development; thus, designers must be able to assess both the performance and cost impacts of their early choices. The Space Based Infrared System (SBIRS) cost engineering model (CEM) described in this paper is an end-to-end process integrating engineering and cost expertise through commonly available spreadsheet software, allowing for concurrent design engineering and cost estimation to identify and balance system drives to reduce acquisition costs. The automated interconnectivity between subsystem models using spreadsheet software allows for the quick and consistent assessment of the system design impacts and relative cost impacts due to requirement changes. It is different from most CEM efforts attempted in the past as it incorporates more detailed spacecraft and sensor payload models, and has been applied to determine the cost drivers for an advanced infrared satellite system acquisition. The CEM is comprised of integrated detailed engineering and cost estimating relationships describing performance, design, and cost parameters. Detailed models have been developed to evaluate design parameters for the spacecraft bus and sensor; both step-starer and scanner sensor types incorporate models of focal plane array, optics, processing, thermal, communications, and mission performance. The current CEM effort has provided visibility to requirements, design, and cost drivers for system architects and decision makers to determine the configuration of an infrared satellite architecture that meets essential requirements cost effectively. In general, the methodology described in this paper consists of process building blocks that can be tailored to the needs of many applications. Descriptions of the spacecraft and payload subsystem models provide insight into The Aerospace Corporation expertise and scope of the SBIRS concept development effort.

  5. Prostate tissue ablation with MRI guided transurethral therapeutic ultrasound and intraoperative assessment of the integrity of the neurovascular bundle

    NASA Astrophysics Data System (ADS)

    Sammet, Steffen; Partanen, Ari; Yousuf, Ambereen; Wardrip, Craig; Niekrasz, Marek; Antic, Tatjana; Razmaria, Aria; Sokka, Sham; Karczmar, Gregory; Oto, Aytekin

    2017-03-01

    OBJECTIVES: Evaluation of the precision of prostate tissue ablation with MRI guided therapeuticultrasound by intraoperative objective assessment of the neurovascular bundle in canines in-vivo. METHODS: In this ongoing IACUC approved study, eight male canines were scanned in a clinical 3T Achieva MRI scanner (Philips) before, during, and after ultrasound therapy with a prototype MR-guided ultrasound therapy system (Philips). The system includes a therapy console to plan treatment, to calculate real-time temperature maps, and to control ultrasound exposures with temperature feedback. Atransurethral ultrasound applicator with eight transducer elements was used to ablate canine prostate tissue in-vivo. Ablated prostate tissue volumes were compared to the prescribed target volumes to evaluate technical effectiveness. The ablated volumes determined by MRI (T1, T2, diffusion, dynamic contrast enhanced and 240 CEM43 thermal dose maps) were compared to H&E stained histological slides afterprostatectomy. Potential nerve damage of the neurovascular bundle was objectively assessed intraoperativelyduring prostatectomy with a CaverMap Surgical Aid nerve stimulator (Blue Torch Medical Technologies). RESULTS: Transurethral MRI -guided ultrasound therapy can effectively ablate canine prostate tissue invivo. Coronal MR-imaging confirmed the correct placement of the HIFU transducer. MRI temperature maps were acquired during HIFU treatment, and subsequently used for calculating thermal dose. Prescribed target volumes corresponded to the 240 CEM43 thermal dose maps during HIFU treatment in all canines. Ablated volumes on high resolution anatomical, diffusion weighted, and contrast enhanced MR images matched corresponding histological slides after prostatectomy. MRI guidance with realtime temperature monitoring showed no damage to surrounding tissues, especially to the neurovascular bundle (assessed intra-operatively with a nerve stimulator) or to the rectum wall. CONCLUSIONS: Our study demonstrates the effectiveness and precision of transurethral ultrasound ablation of prostatic tissue in canines with MRI monitoring and guidance. The canine prostate is an excellent model for the human prostate with similar anatomical characteristics and diseases. MRI guidance with real-time, intraoperative temperature monitoring reduces the risk of damaging critical surrounding anatomical structures in ultrasound therapy of the prostate.

  6. Transformation of primary chick embryo fibroblasts by Marek's disease virus.

    PubMed

    Buranathai, C; Rodriguez, J; Grose, C

    1997-12-08

    Marek's disease virus (MDV) is an alphaherpesvirus, which can mediate the malignant transformation of lymphocytes to form lymphomas in chickens. In this study, we demonstrate that MDV can transform primary chick embryo fibroblasts (CEF). The cell line derived from primary CEF infected with the GA strain of MDV was called CEM(MDV). The fibroblast nature of CEM(MDV) was verified by absence of cytokeratin type II. The CEM(MDV) phenotype differed from either primary CEF or MDV-infected CEF. CEM(MDV) were extensively vacuolated, with unusual multilamellar structures in the cytoplasm, The nuclei were considerably larger than those in primary CEF and were uniformly positive for proliferating cell nuclear antigen. The cell line was subcultured for more than 10 generations; however, CEM(MDV) did not support a fully productive MDV infection, because complete nucleocapsids were not detected and infectivity assays showed that cell line produced no infectious virus. PCR analyses demonstrated that this cell line carried both polypeptide 38 (pp38) and Meq DNA, MDV-specific genes associated with transformation. In addition, examination by laser scanning confocal microscopy revealed that CEM(MDV) constitutively produced MDV MEQ protein in nuclei and pp38 as well as glycoprotein B in the cytoplasm and on the plasma membrane. Growth in soft agar assay demonstrated that CEM(MDV) formed colonies, similar to HeLa and human melanoma cells. Retroviral insertion was not detected in DNA from the CEM(MDV) line.

  7. Evaluation of Four Pulpotomy Techniques in Primary Molars: A Randomized Controlled Trial

    PubMed Central

    Ansari, Ghassem; Morovati, Seyyedeh Pouya; Asgary, Saeed

    2018-01-01

    Introduction: This trial was designed to evaluate the clinical and radiographic success rates of calcium-enriched mixture (CEM) cement with and without low level laser therapy (LLLT) and compare them to that of formocresol (FC) and ferric sulfate (FS) in primary molar pulpotomies. Methods and Materials: This randomized clinical trial was conducted on a total of 160 teeth selected from 40 patients aged 3-9 years. Patients with at least four primary molars needing pulpotomy, were included in order to have each tooth assigned randomly in one of the four following groups; FC, FS, CEM, and LLLT/CEM. Six- and twelve-month follow-up periods were conducted in order to enable a clinical and radiographic evaluation of the treated teeth. Collected data were analyzed using Cochran Q Tests. Results: The 12-month clinical success rate for each technique was: FC=100%, FS=95%, CEM=97.5% and LLLT/CEM=100% with no significant differences (P>0.05). Furthermore, 12-month radiographic success rate for each technique was: FC=100%, FS=92.5%, CEM=95% and LLLT/CEM=100% with no significant differences (P>0.05). Conclusion: Favorable outcomes of four treatment techniques in pulpotomy of primary molar teeth were comparable. CEM with/without LLLT may be considered as a safe and successful pulpotomy treatment modality compared to current conventional methods. PMID:29692828

  8. Improving Power System Modeling. A Tool to Link Capacity Expansion and Production Cost Models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Diakov, Victor; Cole, Wesley; Sullivan, Patrick

    2015-11-01

    Capacity expansion models (CEM) provide a high-level long-term view at the prospects of the evolving power system. In simulating the possibilities of long-term capacity expansion, it is important to maintain the viability of power system operation in the short-term (daily, hourly and sub-hourly) scales. Production-cost models (PCM) simulate routine power system operation on these shorter time scales using detailed load, transmission and generation fleet data by minimizing production costs and following reliability requirements. When based on CEM 'predictions' about generating unit retirements and buildup, PCM provide more detailed simulation for the short-term system operation and, consequently, may confirm the validitymore » of capacity expansion predictions. Further, production cost model simulations of a system that is based on capacity expansion model solution are 'evolutionary' sound: the generator mix is the result of logical sequence of unit retirement and buildup resulting from policy and incentives. The above has motivated us to bridge CEM with PCM by building a capacity expansion - to - production cost model Linking Tool (CEPCoLT). The Linking Tool is built to onset capacity expansion model prescriptions onto production cost model inputs. NREL's ReEDS and Energy Examplar's PLEXOS are the capacity expansion and the production cost models, respectively. Via the Linking Tool, PLEXOS provides details of operation for the regionally-defined ReEDS scenarios.« less

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krishnan, Venkat; Cole, Wesley

    This poster is based on the paper of the same name, presented at the IEEE Power & Energy Society General Meeting, July18, 2016. Power sector capacity expansion models (CEMs) have a broad range of spatial resolutions. This paper uses the Regional Energy Deployment System (ReEDS) model, a long-term national scale electric sector CEM, to evaluate the value of high spatial resolution for CEMs. ReEDS models the United States with 134 load balancing areas (BAs) and captures the variability in existing generation parameters, future technology costs, performance, and resource availability using very high spatial resolution data, especially for wind and solarmore » modeled at 356 resource regions. In this paper we perform planning studies at three different spatial resolutions - native resolution (134 BAs), state-level, and NERC region level - and evaluate how results change under different levels of spatial aggregation in terms of renewable capacity deployment and location, associated transmission builds, and system costs. The results are used to ascertain the value of high geographically resolved models in terms of their impact on relative competitiveness among renewable energy resources.« less

  10. Design, analysis, and testing of the Phase 1 CSI Evolutionary Model erectable truss

    NASA Technical Reports Server (NTRS)

    Gronet, M. J.; Davis, D. A.; Kintis, D. H.; Brillhart, R. D.; Atkins, E. M.

    1992-01-01

    This report addressed the design, analysis, and testing of the erectable truss structure for the Phase 1 CSI Evolutionary Model (CEM) testbed. The Phase 1 CEM testbed is the second testbed to form part of an ongoing program of focused research at NASA/LaRC in the development of Controls-Structures Integration (CSI) technology. The Phase 1 CEM contains the same overall geometry, weight, and sensor locations as the Phase 0 CEM, but is based in an integrated controller and structure design, whereby both structure and controller design variables are sized simultaneously. The Phase 1 CEM design features seven truss sections composed of struts with tailored mass and stiffness properties. A common erectable joint is used and the strut stiffness is tailored by varying the cross-sectional area. To characterize the structure, static tests were conducted on individual struts and 10-bay truss assemblies. Dynamic tests were conducted on 10-bay truss assemblies as well as the fully-assembled CEM truss. The results indicate that the static and dynamic properties of the structure are predictable, well-characterized, and within the performance requirements established during the Phase 1 CEM integrated controller/structure design analysis.

  11. Original behavior of pore water radiolysis in cement-based materials containing sulfide: Coupling between experiments and simulations

    NASA Astrophysics Data System (ADS)

    Bouniol, P.; Guillot, W.; Dauvois, V.; Dridi, W.; Le Caër, S.

    2018-09-01

    Blended cements with high content of blast furnace slag (CEM III/C) can be used for nuclear waste conditioning because of their low hydration heat as compared to ordinary Portland cements (CEM I). They however contain some sulfide, an impurity whose role needs to be investigated. Indeed, they can have an effect on the radiolytic H2 production under irradiation. To study the impact of sulfide species on H2 production, gamma irradiation, at a dose rate of 356 Gy h-1, was performed during 6 months in a closed system without O2 on a cement paste made with CEM III/C. At short time, the radiolytic H2 production rate is higher than that measured using CEM I. On the basis of reaction data collected in the literature on sulfur species, radiolysis simulations performed for both systems confirm this behavior. Moreover, they suggest that the sulfide concentration, initially imposed in pore solution by the slag is of the order of 180 mM, and is responsible for this H2 production. For the first two irradiation months, the following phenomena are then evidenced in CEM III/C: 1) conversion of sulfide into polysulfide anions; 2) pH increase; 3) production of H2 due to the H•+ H2S reaction having a very high rate constant. Nevertheless, in the medium term, the residual sulfide concentration is not sufficient any more for this mechanism to occur. It imposes a reducing environment, leading to a very efficient recombination of H2 in pore solution. The resulting equilibrium state is reinforced by the high liquid saturation level in the cement paste porosity. Therefore, even if the presence of sulfide species in blended cements momentarily increases the H2 production rate, it strongly reduces it at long times.

  12. Early Life Stress and the Anxious Brain: Evidence for A Neural Mechanism Linking Childhood Emotional Maltreatment to Anxiety in Adulthood

    PubMed Central

    Fonzo, Gregory A.; Ramsawh, Holly J.; Flagan, Taru M.; Simmons, Alan N.; Sullivan, Sarah G.; Allard, Carolyn B.; Paulus, Martin P.; Stein, Murray B.

    2016-01-01

    Background Childhood emotional maltreatment (CEM) increases likelihood of developing an anxiety disorder in adulthood, but the neural processes underlying conferment of this risk have not been established. Here, we test the potential for neuroimaging the adult brain to inform understanding of the mechanism linking CEM to adult anxiety symptoms. Methods One hundred eighty-two adults (148 females, 34 males) with a normal-to-clinical range of anxiety symptoms underwent structural and functional magnetic resonance imaging while completing an emotion-processing paradigm with facial expressions of fear, anger, and happiness. Participants completed self-report measures of CEM and current anxiety symptoms. Voxelwise mediation analyses on gray matter volumes and activation to each emotion condition were used to identify candidate brain mechanisms relating CEM to anxiety in adulthood. Results During processing of fear and anger faces, greater amygdala and less right dorsolateral prefrontal (dlPFC) activation partially mediated the positive relationship between CEM and anxiety symptoms. Greater right posterior insula activation to fear also partially mediated this relationship, as did greater ventral anterior cingulate (ACC) and less dorsal ACC activation to anger. Responses to happy faces in these regions did not mediate the CEM-anxiety relationship. Smaller right dlPFC gray matter volumes also partially mediated the CEM-anxiety relationship. Conclusions Activation patterns of the adult brain demonstrate the potential to inform mechanistic accounts of the CEM conferment of anxiety symptoms. Results support the hypothesis that exaggerated limbic activation to negative valence facial emotions links CEM to anxiety symptoms, which may be consequent to a breakdown of cortical regulatory processes. PMID:26670947

  13. 40 CFR 63.9632 - What are the installation, operation, and maintenance requirements for my monitoring equipment?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... document is available on the EPA's Technology Transfer Network at http://www.epa.gov/ttn/emc/cem/tribo.pdf... alignment of each COMS. (3) You must operate and maintain each COMS according to § 63.8(e) and your quality... alignment audit. (4) You must determine and record the 6-minute average opacity for periods during which the...

  14. 40 CFR 63.9632 - What are the installation, operation, and maintenance requirements for my monitoring equipment?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... document is available on the EPA's Technology Transfer Network at http://www.epa.gov/ttn/emc/cem/tribo.pdf... alignment of each COMS. (3) You must operate and maintain each COMS according to § 63.8(e) and your quality... alignment audit. (4) You must determine and record the 6-minute average opacity for periods during which the...

  15. 40 CFR 63.9632 - What are the installation, operation, and maintenance requirements for my monitoring equipment?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... document is available on the EPA's Technology Transfer Network at http://www.epa.gov/ttn/emc/cem/tribo.pdf... alignment of each COMS. (3) You must operate and maintain each COMS according to § 63.8(e) and your quality... alignment audit. (4) You must determine and record the 6-minute average opacity for periods during which the...

  16. The Environmental Assessment and Management (TEAM) Guide: Colorado Supplement

    DTIC Science & Technology

    2010-03-01

    toluene, elthylbenzene, xylene CAR control area responsible party CAS Chemical Abstract Service CEM continuous emission monitoring CERCLA...for electric utility steam generators for which construction is commenced after 18 September 1978 (40 CFR 60, Subpart Da, effective 16 September 1998...except for certain electric generating stations owned and operated by the Public Service Company of Colorado.) Verify that the averaging time for all

  17. 40 CFR Table 7 to Subpart Dddd of... - Continuous Compliance With the Compliance Options and Operating Requirements

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... on THC CEMS data Collecting and recording the THC monitoring data listed in Table 2 to this subpart... according to calculations in § 63.2269(d); AND maintaining the 3-hour block average THC concentration in the exhaust gases less than or equal to the THC concentration established according to § 63.2262. (3) Each...

  18. 40 CFR Table 7 to Subpart Dddd of... - Continuous Compliance With the Compliance Options and Operating Requirements

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... on THC CEMS data Collecting and recording the THC monitoring data listed in Table 2 to this subpart... according to calculations in § 63.2269(d); AND maintaining the 3-hour block average THC concentration in the exhaust gases less than or equal to the THC concentration established according to § 63.2262. (3) Each...

  19. On-line capillary electrophoresis/laser-induced fluorescence/mass spectrometry analysis of glycans labeled with Teal™ fluorescent dye using an electrokinetic sheath liquid pump-based nanospray ion source.

    PubMed

    Khan, Shaheer; Liu, Jenkuei; Szabo, Zoltan; Kunnummal, Baburaj; Han, Xiaorui; Ouyang, Yilan; Linhardt, Robert J; Xia, Qiangwei

    2018-06-15

    N-linked glycan analysis of recombinant therapeutic proteins, such as monoclonal antibodies, Fc-fusion proteins, and antibody-drug conjugates, provides valuable information regarding protein therapeutics glycosylation profile. Both qualitative identification and quantitative analysis of N-linked glycans on recombinant therapeutic proteins are critical analytical tasks in the biopharma industry during the development of a biotherapeutic. Currently, such analyses are mainly carried out using capillary electrophoresis/laser-induced fluorescence (CE/LIF), liquid chromatography/fluorescence (LC/FLR), and liquid chromatography/fluorescence/mass spectrometry (LC/FLR/MS) technologies. N-linked glycans are first released from glycoproteins by enzymatic digestion, then labeled with fluorescence dyes for subsequent CE or LC separation, and LIF or MS detection. Here we present an on-line CE/LIF/MS N-glycan analysis workflow that incorporates the fluorescent Teal™ dye and an electrokinetic pump-based nanospray sheath liquid capillary electrophoresis/mass spectrometry (CE/MS) ion source. Electrophoresis running buffer systems using ammonium acetate and ammonium hydroxide were developed for the negative ion mode CE/MS analysis of fluorescence-labeled N-linked glycans. Results show that on-line CE/LIF/MS analysis can be readily achieved using this versatile CE/MS ion source on common CE/MS instrument platforms. This on-line CE/LIF/MS method using Teal™ fluorescent dye and electrokinetic pump-based nanospray sheath liquid CE/MS coupling technology holds promise for on-line quantitation and identification of N-linked glycans on recombinant therapeutic proteins. Copyright © 2018 John Wiley & Sons, Ltd.

  20. Train-to-Train Impact Test of Crash-Energy Management Passenger Rail Equipment: Occupant Experiments

    DOT National Transportation Integrated Search

    2006-11-06

    As part of an ongoing passenger rail crashworthiness effort, : a full-scale impact test of a train with crash energy management : (CEM) passenger cars was conducted on March 23, 2006. In : this test, a train made up of a CEM cab car, four CEM coach :...

  1. Extraction of Carbon Dioxide and Hydrogen from Seawater By an Electrolytic Cation Exchange Module (E-CEM) Part 5: E-CEM Effluent Discharge Composition as a Function of Electrode Water Composition

    DTIC Science & Technology

    2017-08-01

    Naval Research Laboratory Washington, DC 20375-5320 NRL/MR/6360--17-9743 Extraction of Carbon Dioxide and Hydrogen from Seawater by an Electrolytic...Cation Exchange Module (E-CEM) Part V: E-CEM Effluent Discharge Composition as a Function of Electrode Water Composition August 1, 2017 Approved for...Office of Naval Research Arlington, Virginia Dennis r. HarDy Nova Research Inc. Alexandria, Virginia i REPORT DOCUMENTATION PAGE Form

  2. FPGA design for constrained energy minimization

    NASA Astrophysics Data System (ADS)

    Wang, Jianwei; Chang, Chein-I.; Cao, Mang

    2004-02-01

    The Constrained Energy Minimization (CEM) has been widely used for hyperspectral detection and classification. The feasibility of implementing the CEM as a real-time processing algorithm in systolic arrays has been also demonstrated. The main challenge of realizing the CEM in hardware architecture in the computation of the inverse of the data correlation matrix performed in the CEM, which requires a complete set of data samples. In order to cope with this problem, the data correlation matrix must be calculated in a causal manner which only needs data samples up to the sample at the time it is processed. This paper presents a Field Programmable Gate Arrays (FPGA) design of such a causal CEM. The main feature of the proposed FPGA design is to use the Coordinate Rotation DIgital Computer (CORDIC) algorithm that can convert a Givens rotation of a vector to a set of shift-add operations. As a result, the CORDIC algorithm can be easily implemented in hardware architecture, therefore in FPGA. Since the computation of the inverse of the data correlction involves a series of Givens rotations, the utility of the CORDIC algorithm allows the causal CEM to perform real-time processing in FPGA. In this paper, an FPGA implementation of the causal CEM will be studied and its detailed architecture will be also described.

  3. CSI Flight Computer System and experimental test results

    NASA Technical Reports Server (NTRS)

    Sparks, Dean W., Jr.; Peri, F., Jr.; Schuler, P.

    1993-01-01

    This paper describes the CSI Computer System (CCS) and the experimental tests performed to validate its functionality. This system is comprised of two major components: the space flight qualified Excitation and Damping Subsystem (EDS) which performs controls calculations; and the Remote Interface Unit (RIU) which is used for data acquisition, transmission, and filtering. The flight-like RIU is the interface between the EDS and the sensors and actuators positioned on the particular structure under control. The EDS and RIU communicate over the MIL-STD-1553B, a space flight qualified bus. To test the CCS under realistic conditions, it was connected to the Phase-0 CSI Evolutionary Model (CEM) at NASA Langley Research Center. The following schematic shows how the CCS is connected to the CEM. Various tests were performed which validated the ability of the system to perform control/structures experiments.

  4. Readiness of district and regional hospitals in Burkina Faso to provide caesarean section and blood transfusion services: a cross-sectional study.

    PubMed

    Compaoré, Georges Dayitaba; Sombié, Issiaka; Ganaba, Rasmané; Hounton, Sennen; Meda, Nicolas; Brouwere, Vincent De; Borchert, Matthias

    2014-05-02

    Health centres and hospitals play a crucial role in reducing maternal mortality and morbidity by offering respectively Basic Emergency Obstetric and Newborn Care (BEmONC) and Comprehensive Emergency Obstetric and Newborn Care (CEmONC). The readiness of hospitals to provide CEmONC depends on the availability of qualified human resources, infrastructure like surgical theatres, and supplies like drugs and blood for transfusion. We assessed the readiness of district and regional hospitals in Burkina Faso to provide two key CEmONC functions, namely caesarean section and blood transfusion. As countries conduct EmONC needs assessments it is critical to provide national and subnational data, e.g. on the distribution of EmONC facilities as well as on facilities lacking the selected signal functions, to support the planning process for upgrading facilities so that they are ready to provide CEmONC. In a cross-sectional study we assessed the availability of relevant health workers, obstetric guidelines, caesarean section and blood transfusion services and experience with quality assurance approaches across all forty-three (43) district and nine (9) regional hospitals. The indicator corresponding to one comprehensive emergency care unit for 500,000 inhabitants was not achieved in Burkina Faso. Physicians with surgical skills, surgical assistants and anaesthesiologist assistants are sufficiently available in only 51.2%, 88.3% and 72.0% of district hospitals, respectively. Two thirds of regional and 20.9% of district hospitals had blood banks. Most district hospitals as opposed to only one third of regional hospitals had experience in maternal death reviews. Our findings suggest that only 27.8% of hospitals in Burkina Faso at the time of the study could continuously offer caesarean sections and blood transfusion services. Four years later, progress has likely been made but many challenges remain to be overcome. Information provided in this study can serve as a baseline for monitoring progress in district and regional hospitals.

  5. 40 CFR 63.1349 - Performance testing requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) THC emissions test. (i) If you are subject to limitations on THC emissions, you must operate a CEMS in... assurance evaluations for CEMS, the THC span value (as propane) is 50 ppmvd and the reference method (RM) is Method 25A of appendix A to part 60 of this chapter. (ii) Use the THC CEMS to conduct the initial...

  6. Changes in cigarette expenditure minimising strategies before and after a cigarette tax increase.

    PubMed

    Choi, Kelvin; Boyle, Raymond G

    2018-01-01

    Smokers use cigarette expenditure minimising strategies (CEMS) to alleviate the effect of tax increases on their cigarette expenses. We examined changes in smokers' CEMS use before and after a 2013 Minnesota $1.75 cigarette tax increase. Data were from representative samples of smokers who participated in the Minnesota Adult Tobacco Survey 2010 (n=948) and 2014 (n=1229). Participants indicated CEMS used in the past year from a list. Weighted multiple logistic regressions were used to examine changes in prevalence of each CEMS use over time adjusting for demographics and cigarette consumption. Characteristics associated with CEMS use in 2014 were examined. Between 2010 and 2014, more smokers tried to save money on cigarettes by rolling their own cigarettes (from 19% to 29%), using other tobacco products (from 13% to 25%), and buying cigarettes from cheaper places (from 48% to 55%). Yet, fewer smokers used coupons/promotions (from 63% to 50%) and bought cigarettes by the carton (from 39% to 32%). These changes varied somewhat by race/ethnicity and education, for example, more smokers with

  7. CEM2k and LAQGSM Codes as Event-Generators for Space Radiation Shield and Cosmic Rays Propagation Applications

    NASA Technical Reports Server (NTRS)

    Mashnik, S. G.; Gudima, K. K.; Sierk, A. J.; Moskalenko, I. V.

    2002-01-01

    Space radiation shield applications and studies of cosmic ray propagation in the Galaxy require reliable cross sections to calculate spectra of secondary particles and yields of the isotopes produced in nuclear reactions induced both by particles and nuclei at energies from threshold to hundreds of GeV per nucleon. Since the data often exist in a very limited energy range or sometimes not at all, the only way to obtain an estimate of the production cross sections is to use theoretical models and codes. Recently, we have developed improved versions of the Cascade-Exciton Model (CEM) of nuclear reactions: the codes CEM97 and CEM2k for description of particle-nucleus reactions at energies up to about 5 GeV. In addition, we have developed a LANL version of the Quark-Gluon String Model (LAQGSM) to describe reactions induced both by particles and nuclei at energies up to hundreds of GeVhucleon. We have tested and benchmarked the CEM and LAQGSM codes against a large variety of experimental data and have compared their results with predictions by other currently available models and codes. Our benchmarks show that CEM and LAQGSM codes have predictive powers no worse than other currently used codes and describe many reactions better than other codes; therefore both our codes can be used as reliable event-generators for space radiation shield and cosmic ray propagation applications. The CEM2k code is being incorporated into the transport code MCNPX (and several other transport codes), and we plan to incorporate LAQGSM into MCNPX in the near future. Here, we present the current status of the CEM2k and LAQGSM codes, and show results and applications to studies of cosmic ray propagation in the Galaxy.

  8. Software for Estimating Costs of Testing Rocket Engines

    NASA Technical Reports Server (NTRS)

    Hines, Merlon M.

    2004-01-01

    A high-level parametric mathematical model for estimating the costs of testing rocket engines and components at Stennis Space Center has been implemented as a Microsoft Excel program that generates multiple spreadsheets. The model and the program are both denoted, simply, the Cost Estimating Model (CEM). The inputs to the CEM are the parameters that describe particular tests, including test types (component or engine test), numbers and duration of tests, thrust levels, and other parameters. The CEM estimates anticipated total project costs for a specific test. Estimates are broken down into testing categories based on a work-breakdown structure and a cost-element structure. A notable historical assumption incorporated into the CEM is that total labor times depend mainly on thrust levels. As a result of a recent modification of the CEM to increase the accuracy of predicted labor times, the dependence of labor time on thrust level is now embodied in third- and fourth-order polynomials.

  9. Software for Estimating Costs of Testing Rocket Engines

    NASA Technical Reports Server (NTRS)

    Hines, Merion M.

    2002-01-01

    A high-level parametric mathematical model for estimating the costs of testing rocket engines and components at Stennis Space Center has been implemented as a Microsoft Excel program that generates multiple spreadsheets. The model and the program are both denoted, simply, the Cost Estimating Model (CEM). The inputs to the CEM are the parameters that describe particular tests, including test types (component or engine test), numbers and duration of tests, thrust levels, and other parameters. The CEM estimates anticipated total project costs for a specific test. Estimates are broken down into testing categories based on a work-breakdown structure and a cost-element structure. A notable historical assumption incorporated into the CEM is that total labor times depend mainly on thrust levels. As a result of a recent modification of the CEM to increase the accuracy of predicted labor times, the dependence of labor time on thrust level is now embodied in third- and fourth-order polynomials.

  10. Software for Estimating Costs of Testing Rocket Engines

    NASA Technical Reports Server (NTRS)

    Hines, Merlon M.

    2003-01-01

    A high-level parametric mathematical model for estimating the costs of testing rocket engines and components at Stennis Space Center has been implemented as a Microsoft Excel program that generates multiple spreadsheets. The model and the program are both denoted, simply, the Cost Estimating Model (CEM). The inputs to the CEM are the parameters that describe particular tests, including test types (component or engine test), numbers and duration of tests, thrust levels, and other parameters. The CEM estimates anticipated total project costs for a specific test. Estimates are broken down into testing categories based on a work-breakdown structure and a cost-element structure. A notable historical assumption incorporated into the CEM is that total labor times depend mainly on thrust levels. As a result of a recent modification of the CEM to increase the accuracy of predicted labor times, the dependence of labor time on thrust level is now embodied in third- and fourth-order polynomials.

  11. A small, lightweight multipollutant sensor system for ground-mobile and aerial emission sampling from open area sources

    NASA Astrophysics Data System (ADS)

    Zhou, Xiaochi; Aurell, Johanna; Mitchell, William; Tabor, Dennis; Gullett, Brian

    2017-04-01

    Characterizing highly dynamic, transient, and vertically lofted emissions from open area sources poses unique measurement challenges. This study developed and applied a multipollutant sensor and time-integrated sampler system for use on mobile applications such as vehicles, tethered balloons (aerostats) and unmanned aerial vehicles (UAVs) to determine emission factors. The system is particularly applicable to open area sources, such as forest fires, due to its light weight (3.5 kg), compact size (6.75 L), and internal power supply. The sensor system, termed ;Kolibri;, consists of sensors measuring CO2 and CO, and samplers for particulate matter (PM) and volatile organic compounds (VOCs). The Kolibri is controlled by a microcontroller which can record and transfer data in real time through a radio module. Selection of the sensors was based on laboratory testing for accuracy, response delay and recovery, cross-sensitivity, and precision. The Kolibri was compared against rack-mounted continuous emissions monitoring system (CEMs) and another mobile sampling instrument (the ;Flyer;) that has been used in over ten open area pollutant sampling events. Our results showed that the time series of CO, CO2, and PM2.5 concentrations measured by the Kolibri agreed well with those from the CEMs and the Flyer, with a laboratory-tested percentage error of 4.9%, 3%, and 5.8%, respectively. The VOC emission factors obtained using the Kolibri were consistent with existing literature values that relate concentration to modified combustion efficiency. The potential effect of rotor downwash on particle sampling was investigated in an indoor laboratory and the preliminary results suggested that its influence is minimal. Field application of the Kolibri sampling open detonation plumes indicated that the CO and CO2 sensors responded dynamically and their concentrations co-varied with emission transients. The Kolibri system can be applied to various challenging open area scenarios such as fires, lagoons, flares, and landfills.

  12. Capillary Electrophoresis-nanoelectrospray Ionization-selected Reaction Monitoring Mass Spectrometry Via A True Sheathless Metal-coated Emitter Interface For Robust And High Sensitivity Sample Quantification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guo, Xuejiang; Fillmore, Thomas L.; Gao, Yuqian

    A new sheathless CITP/CZE-MS interface, based on a commercially available capillary with an integrated metal coated ESI emitter, was developed in this study aiming at overcoming the reproducibility and ruggedness problems, suffered to a certain degree by almost all the available CE-MS interfaces, and pushing the CE-MS technology suitable for routine sample analysis with high sensitivity. The new CITP/CZE-MS interface allows the electric contact between ESI voltage power supply and the CE separation liquid by using a conductive liquid that comes in contact with the metal coated surface of the ESI emitter, making it a true sheathless CE-MS interface. Stablemore » electrospray was established by avoiding the formation of gas bubbles from electro chemical reaction at the emitter tip or inside of the CE capillary. Crucial operating parameters, such as sample loading volume, flow rate, and separation voltage, were systematically evaluated for their effects on both CITP/CZE separation efficiency and MS detection sensitivity. Around one hundred CITP/CZE-MS analyses can be easily achieved by using the new sheathless CITP/CZE interface without a noticeable loss of metal coating on the ESI emitter surface, or degrading of the ESI emitter performance. The reproducibility in analyte migration time and quantitative performance of the new interface was experimentally evaluated to demonstrate a LOQ bellow 5 attomole.« less

  13. Publications - PIR 2015-6 | Alaska Division of Geological & Geophysical

    Science.gov Websites

    content DGGS PIR 2015-6 Publication Details Title: Geologic map of the Talkeetna Mountains C-4 Quadrangle ., Freeman, L.K., and Lande, L.L., 2015, Geologic map of the Talkeetna Mountains C-4 Quadrangle and adjoining Sheets Sheet 1 Geologic map of the Talkeetna Mountains C-4 Quadrangle and adjoining areas, central Alaska

  14. 40 CFR Table 1 to Subpart Lll of... - Applicability of General Provisions

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... CMS Recordkeeping Yes PS-8A supersedes requirements for THC CEMS. 63.10(c)(1) Additional CMS Recordkeeping Yes PS-8A supersedes requirements for THC CEMS. 63.10(c)(2)-(4) No [Reserved] 63.10(c)(5)-(8) Additional CMS Recordkeeping Yes PS-8A supersedes requirements for THC CEMS. 63.10(c)(9) No [Reserved] 63.10...

  15. 40 CFR Table 1 to Subpart Lll of... - Applicability of General Provisions

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... CMS Recordkeeping Yes PS-8A supersedes requirements for THC CEMS. 63.10(c)(1) Additional CMS Recordkeeping Yes PS-8A supersedes requirements for THC CEMS. 63.10(c)(2)-(4) No [Reserved] 63.10(c)(5)-(8) Additional CMS Recordkeeping Yes PS-8A supersedes requirements for THC CEMS. 63.10(c)(9) No [Reserved] 63.10...

  16. Strategies Involving Mass Spectrometry Combined with Capillary Electrophoresis in Metabolomics.

    PubMed

    Rodrigues, Karina Trevisan; Cieslarová, Zuzana; Tavares, Marina Franco Maggi; Simionato, Ana Valéria Colnaghi

    2017-01-01

    This chapter focuses on the important contribution of CE-MS in metabolomics, describing the nature of CE-MS coupling and the technical improvements that have led to the interfaces used in modern instrumentation. Moreover, it will discourse how the variety of electrolyte compositions and additives, which has conferred CE the exceptional selectivity of its multiple separation modes, has been handled to allow interfacing with MS without compromising ionization efficiency and the spectrometer integrity. Finally, the methodologies of CE-MS in current use for metabolomics will be discussed in detail. To verify the scope of CE-MS in clinical metabolomics, a myriad of representative applications has been compiled.

  17. Light curing through glass ceramics: effect of curing mode on micromechanical properties of dual-curing resin cements.

    PubMed

    Flury, Simon; Lussi, Adrian; Hickel, Reinhard; Ilie, Nicoleta

    2014-04-01

    The aim of this study was to investigate micromechanical properties of five dual-curing resin cements after different curing modes including light curing through glass ceramic materials. Vickers hardness (VH) and indentation modulus (Y HU) of Panavia F2.0, RelyX Unicem 2 Automix, SpeedCEM, BisCem, and BeautiCem SA were measured after 1 week of storage (37 °C, 100 % humidity). The resin cements were tested following self-curing or light curing with the second-generation light-emitting diode (LED) curing unit Elipar FreeLight 2 in Standard Mode (1,545 mW/cm(2)) or with the third-generation LED curing unit VALO in High Power Mode (1,869 mW/cm(2)) or in XtraPower Mode (3,505 mW/cm(2)). Light curing was performed directly or through glass ceramic discs of 1.5 or 3 mm thickness of IPS Empress CAD or IPS e.max CAD. VH and Y HU were analysed with Kruskal-Wallis tests followed by pairwise Wilcoxon rank sum tests (α = 0.05). RelyX Unicem 2 Automix resulted in the highest VH and Y HU followed by BeautiCem SA, BisCem, SpeedCEM, and finally Panavia F2.0. Self-curing of RelyX Unicem 2 Automix and SpeedCEM lowered VH and Y HU compared to light curing whereas self-curing of Panavia F2.0, BisCem, and BeautiCem SA led to similar or significantly higher VH and Y HU compared to light curing. Generally, direct light curing resulted in similar or lower VH and Y HU compared to light curing through 1.5-mm-thick ceramic discs. Light curing through 3-mm-thick discs of IPS e.max CAD generally reduced VH and Y HU for all resin cements except SpeedCEM, which was the least affected by light curing through ceramic discs. The resin cements responded heterogeneously to changes in curing mode. The applied irradiances and light curing times adequately cured the resin cements even through 1.5-mm-thick ceramic discs. When light curing resin cements through thick glass ceramic restorations, clinicians should consider to prolong the light curing times even with LED curing units providing high irradiances.

  18. The role of CSP in Brazil: A multi-model analysis

    NASA Astrophysics Data System (ADS)

    Soria, Rafael; Lucena, André F. P.; Tomaschek, Jan; Fichter, Tobias; Haasz, Thomas; Szklo, Alexandre; Schaeffer, Roberto; Rochedo, Pedro; Fahl, Ulrich; Kern, Jürgen; Hoffmann, Susanne

    2016-05-01

    MESSAGE, TIMES and REMIX-CEM are potential tools for modelling a larger penetration of variable renewable energy (VRE) into the Brazilian power system. They also allow devising the opportunities that concentrated solar power (CSP) plants offer to the power system and to the wider energy system. There are different opportunities for CSP in Brazil in the short and medium term, consolidating this technology as a feasible alternative for greenhouse gas (GHG) mitigation in Brazil. This work verified that CSP is a cost-effective option only under very stringent mitigation scenarios (4DS and 2DS) and when carbon capture and storage (CCS) is not available. Still, according to the findings of REMIX-CEM-B, CSP can provide firm energy and dispatchable capacity in the Northeast region of Brazil, optimally complementing wind and PV generation. Moreover, CSP can offer additional flexibility to the Northeast power system, especially during winter and after 2030.

  19. Posterior Orbitofrontal and Anterior Cingulate Pathways to the Amygdala Target Inhibitory and Excitatory Systems with Opposite Functions.

    PubMed

    Zikopoulos, Basilis; Höistad, Malin; John, Yohan; Barbas, Helen

    2017-05-17

    The bidirectional dialogue of the primate posterior orbitofrontal cortex (pOFC) with the amygdala is essential in cognitive-emotional functions. The pOFC also sends a uniquely one-way excitatory pathway to the amygdalar inhibitory intercalated masses (IM), which inhibit the medial part of the central amygdalar nucleus (CeM). Inhibition of IM has the opposite effect, allowing amygdalar activation of autonomic structures and emotional arousal. Using multiple labeling approaches to identify pathways and their postsynaptic sites in the amygdala in rhesus monkeys, we found that the anterior cingulate cortex innervated mostly the basolateral and CeM amygdalar nuclei, poised to activate CeM for autonomic arousal. By contrast, a pathway from pOFC to IM exceeded all other pathways to the amygdala by density and size and proportion of large and efficient terminals. Moreover, whereas pOFC terminals in IM innervated each of the three distinct classes of inhibitory neurons, most targeted neurons expressing dopamine- and cAMP-regulated phosphoprotein (DARPP-32+), known to be modulated by dopamine. The predominant pOFC innervation of DARPP-32+ neurons suggests activation of IM and inhibition of CeM, resulting in modulated autonomic function. By contrast, inhibition of DARPP-32 neurons in IM by high dopamine levels disinhibits CeM and triggers autonomic arousal. The findings provide a mechanism to help explain how a strong pOFC pathway, which is poised to moderate activity of CeM, through IM, can be undermined by the high level of dopamine during stress, resulting in collapse of potent inhibitory mechanisms in the amygdala and heightened autonomic drive, as seen in chronic anxiety disorders. SIGNIFICANCE STATEMENT The dialogue between prefrontal cortex and amygdala allows thoughts and emotions to influence actions. The posterior orbitofrontal cortex sends a powerful pathway that targets a special class of amygdalar intercalated mass (IM) inhibitory neurons, whose wiring may help modulate autonomic function. By contrast, the anterior cingulate cortex innervates other amygdalar parts, activating circuits to help avoid danger. Most IM neurons in primates label for the protein DARPP-32, known to be activated or inhibited based on the level of dopamine. Stress markedly increases dopamine release and inhibits IM neurons, compromises prefrontal control of the amygdala, and sets off a general alarm system as seen in affective disorders, such as chronic anxiety and post-traumatic stress disorder. Copyright © 2017 the authors 0270-6474/17/375051-14$15.00/0.

  20. Cement Type Influence on Alkali-Silica Reaction in Concrete with Crushed Gravel Aggregate

    NASA Astrophysics Data System (ADS)

    Rutkauskas, A.; Nagrockienė, D.; Skripkiūnas, G.

    2017-10-01

    Alkali-silica reaction is one of the chemical reactions which have a significant influence for durability of concrete. During alkali and silica reaction, silicon located in aggregates of the concrete, reacts with high alkali content. This way in the micropores of concrete is forming hygroscopic gel, which at wet environment, expanding and slowly but strongly destroying concrete structures. The goal of this paper- to determine the influence of cement type on alkali-silica reaction of mortars with crushed gravel. In the study crushed gravel with fraction 4/16 mm was used and four types of cements tested: CEM I 42.5 R; CEM I 42.5 SR; CEM II/A-S 42.5; CEM II/A-V 52.5. This study showed that crushed gravel is low contaminated on reactive particles containing of amorphous silica dioxide. The expansion after 14 days exceed 0.054 %, by RILEM AAR-2 research methodology (testing specimen dimension 40×40×160 mm). Continuing the investigation to 56 days for all specimens occurred alkaline corrosion features: microcracking and the surface plaque of gel. The results showed that the best resistance to alkaline corrosion after 14 days was obtained with cement CEM I 42.5 SR containing ash additive, and after 56 days with cement CEM II/A-V 52.5 containing low alkali content. The highest expansion after 14 and 56 days was obtained with cement CEM I 42.5 R without active mineral additives.

  1. The development and application of landscape evolution models to coupled coast-estuarine environments

    NASA Astrophysics Data System (ADS)

    Morris, Chloe; Coulthard, Tom; Parsons, Daniel R.; Manson, Susan; Barkwith, Andrew

    2017-04-01

    Landscape Evolution Models (LEMs) are proven to be useful tools in understanding the morphodynamics of coast and estuarine systems. However, perhaps owing to the lack of research in this area, current models are not capable of simulating the dynamic interactions between these systems and their co-evolution at the meso-scale. Through a novel coupling of numerical models, this research is designed to explore coupled coastal-estuarine interactions, controls on system behaviour and the influence that environmental change could have. This will contribute to the understanding of the morphodynamics of these systems and how they may behave and evolve over the next century in response to climate changes, with the aim of informing management practices. This goal is being achieved through the modification and coupling of the one-line Coastline Evolution Model (CEM) with the hydrodynamic LEM CAESAR-Lisflood (C-L). The major issues faced with coupling these programs are their differing complexities and the limited graphical visualisations produced by the CEM that hinder the dissemination of results. The work towards overcoming these issues and reported here, include a new version of the CEM that incorporates a range of more complex geomorphological processes and boasts a graphical user interface that guides users through model set-up and projects a live output during model runs. The improved version is a stand-alone tool that can be used for further research projects and for teaching purposes. A sensitivity analysis using the Morris method has been completed to identify which key variables, including wave climate, erosion and weathering values, dominate the control of model behaviour. The model is being applied and tested using the evolution of the Holderness Coast, Humber Estuary and Spurn Point on the east coast of England (UK), which possess diverse geomorphologies and complex, co-evolving sediment pathways. Simulations using the modified CEM are currently being completed to ascertain the processes influential to the morphodynamics and evolution of these systems; presently this includes increasing sea levels and changing wave climate patterns. Outputs and findings from these runs will be presented and discussed, with the aid of the improved graphical visualisations and animations that illustrate the evolution of simulated environments.

  2. Kinematic optimization of upgrade to the Hobby-Eberly Telescope through novel use of commercially available three-dimensional CAD package

    NASA Astrophysics Data System (ADS)

    Wedeking, Gregory A.; Zierer, Joseph J.; Jackson, John R.

    2010-07-01

    The University of Texas, Center for Electromechanics (UT-CEM) is making a major upgrade to the robotic tracking system on the Hobby Eberly Telescope (HET) as part of theWide Field Upgrade (WFU). The upgrade focuses on a seven-fold increase in payload and necessitated a complete redesign of all tracker supporting structure and motion control systems, including the tracker bridge, ten drive systems, carriage frames, a hexapod, and many other subsystems. The cost and sensitivity of the scientific payload, coupled with the tracker system mass increase, necessitated major upgrades to personnel and hardware safety systems. To optimize kinematic design of the entire tracker, UT-CEM developed novel uses of constraints and drivers to interface with a commercially available CAD package (SolidWorks). For example, to optimize volume usage and minimize obscuration, the CAD software was exercised to accurately determine tracker/hexapod operational space needed to meet science requirements. To verify hexapod controller models, actuator travel requirements were graphically measured and compared to well defined equations of motion for Stewart platforms. To ensure critical hardware safety during various failure modes, UT-CEM engineers developed Visual Basic drivers to interface with the CAD software and quickly tabulate distance measurements between critical pieces of optical hardware and adjacent components for thousands of possible hexapod configurations. These advances and techniques, applicable to any challenging robotic system design, are documented and describe new ways to use commercially available software tools to more clearly define hardware requirements and help insure safe operation.

  3. 40 CFR Table 1 to Subpart Lll of... - Applicability of General Provisions

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Yes PS-8A supersedes requirements for THC CEMS. 63.10(c)(1) Additional CMS Recordkeeping Yes PS-8A supersedes requirements for THC CEMS. 63.10(c)(2)-(4) No [Reserved] 63.10(c)(5)-(8) Additional CMS Recordkeeping Yes PS-8A supersedes requirements for THC CEMS. 63.10(c)(9) No [Reserved] 63.10(c)(10)-(15...

  4. 40 CFR Table 1 to Subpart Lll of... - Applicability of General Provisions

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Yes PS-8A supersedes requirements for THC CEMS. 63.10(c)(1) Additional CMS Recordkeeping Yes PS-8A supersedes requirements for THC CEMS. 63.10(c)(2)-(4) No [Reserved] 63.10(c)(5)-(8) Additional CMS Recordkeeping Yes PS-8A supersedes requirements for THC CEMS. 63.10(c)(9) No [Reserved] 63.10(c)(10)-(15...

  5. Emergency obstetric and neonatal care availability, use, and quality: a cross-sectional study in the city of Lubumbashi, Democratic Republic of the Congo, 2011.

    PubMed

    Ntambue, Abel Mukengeshayi; Malonga, Françoise Kaj; Cowgill, Karen D; Dramaix-Wilmet, Michèle; Donnen, Philippe

    2017-01-19

    While emergency obstetric and neonatal care (EmONC) is a proxy indicator for monitoring maternal and perinatal mortalities, in Democratic Republic of the Congo (DRC), data on this care is rarely available. In the city of Lubumbashi, the second largest in DRC with an estimated population of 1.5 million, the availability, use and quality of EmONC are not known. This study aimed to assess these elements in Lubumbashi. This cross-sectional survey was conducted in April and May 2011. Fifty-three of the 180 health facilities that provide maternity care in Lubumbashi were included in this study. Only health facilities with at least six deliveries per month over the course of 2010 were included. The availability, use and quality of EmONC at each level of the health care system were assessed according to the WHO standards. The availability of EmONC in Lubumbashi falls short of WHO standards. In this study, we found one facility providing Comprehensive EmONC (CEmONC) for a catchment area of 918,819 inhabitants. Apart from the tertiary hospital (Sendwe), no other facility provided all the basic emergency obstetric and neonatal care (BEmONC) signal functions. However, all had carried out at least one of the nine signal functions during the 3 months preceding our survey: 73.6% of 53 facilities had administered parenteral antibiotics, 79.2% had systematically offered oxytocics, 39.6% had administered magnesium sulfate, 73.6% had manually evacuated placentas, 81.1% had removed retained placenta products, 54.7% had revived newborns, 35.8% had performed caesarean sections, and 47.2% had performed blood transfusions. Function 6, vaginal delivery assisted by ventouse or forceps, was performed in only two (3.8%) facilities. If this signal function was not taken into account in our assessment of EmONC availability, there would be five facilities providing CEmONC for 918,819 inhabitants, rather than one. In 2010, all the women in the surveyed facilities with obstetric complications delivered in facilities that had carried out at least one signal function in the 3 months before our survey; 7.0% of these women delivered in the facility which provided CEmONC. Mortality due to direct obstetric causes was 3.9% in the health facility that provided CEmONC. The intrapartum mortality was also high in this facility (5.1%). None of the maternity ward managers in any of the facilities surveyed had received training on the EmONC package. Essential supplies and equipment for performing certain EmONC functions were not available in all the surveyed facilities. Audits of maternal and neonatal deaths and near-misses should be established and used as a basis for monitoring the quality of care in Lubumbashi. To reduce maternal and perinatal mortality, it is essential that staff skills regarding EmONC be strengthened, the availability of supplies and equipment be increased, and that care processes be standardized in all health facilities in Lubumbashi.

  6. CEMS study of strain induced phase transformation in manganese Hadfield steel

    NASA Astrophysics Data System (ADS)

    Cabanillas, E. D.; Alvarez, E. P.; Hey, A.; Mercader, R. C.

    1991-11-01

    A Conversion Electron Mössbauer Spectroscopy, (CEMS), study of phase transformations in a Hadfield steel induced by high rate strains is reported. Hadfield steel samples were impact deformed and the ensuing changes in the magnetic properties at the deformed zone and its surroundings have been studied by CEMS. The CEMS results are compared with wear tests and optical microscopy and show a formation of martensite by impact deformation only at the surface. Martensite is not produced by compression or tensile stresses but appears after wear tests in proportions that depend on the load and velocity conditions of test. The understanding of martensite phase formation and its evolution during deformation processes is also addressed.

  7. Temporalization of Electric Generation Emissions for Improved Representation of Peak Air Quality Episodes

    NASA Astrophysics Data System (ADS)

    Farkas, C. M.; Moeller, M.; Carlton, A. G.

    2013-12-01

    Photochemical transport models routinely under predict peak air quality events. This deficiency may be due, in part, to inadequate temporalization of emissions from the electric generating sector. The National Emissions Inventory (NEI) reports emissions from Electric Generating Units (EGUs) by either Continuous Emission Monitors (CEMs) that report hourly values or as an annual total. The Sparse Matrix Operator Kernel Emissions preprocessor (SMOKE), used to prepare emissions data for modeling with the CMAQ air quality model, allocates annual emission totals throughout the year using specific monthly, weekly, and hourly weights according to standard classification code (SCC) and location. This approach represents average diurnal and seasonal patterns of electricity generation but does not capture spikes in emissions due to episodic use as with peaking units or due to extreme weather events. In this project we use a combination of state air quality permits, CEM data, and EPA emission factors to more accurately temporalize emissions of NOx, SO2 and particulate matter (PM) during the extensive heat wave of July and August 2006. Two CMAQ simulations are conducted; the first with the base NEI emissions and the second with improved temporalization, more representative of actual emissions during the heat wave. Predictions from both simulations are evaluated with O3 and PM measurement data from EPA's National Air Monitoring Stations (NAMS) and State and Local Air Monitoring Stations (SLAMS) during the heat wave, for which ambient concentrations of criteria pollutants were often above NAAQS. During periods of increased photochemistry and high pollutant concentrations, it is critical that emissions are most accurately represented in air quality models.

  8. Total reaction cross sections in CEM and MCNP6 at intermediate energies

    DOE PAGES

    Kerby, Leslie M.; Mashnik, Stepan G.

    2015-05-14

    Accurate total reaction cross section models are important to achieving reliable predictions from spallation and transport codes. The latest version of the Cascade Exciton Model (CEM) as incorporated in the code CEM03.03, and the Monte Carlo N-Particle transport code (MCNP6), both developed at Los Alamos National Laboratory (LANL), each use such cross sections. Having accurate total reaction cross section models in the intermediate energy region (50 MeV to 5 GeV) is very important for different applications, including analysis of space environments, use in medical physics, and accelerator design, to name just a few. The current inverse cross sections used inmore » the preequilibrium and evaporation stages of CEM are based on the Dostrovsky et al. model, published in 1959. Better cross section models are now available. Implementing better cross section models in CEM and MCNP6 should yield improved predictions for particle spectra and total production cross sections, among other results.« less

  9. Total reaction cross sections in CEM and MCNP6 at intermediate energies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kerby, Leslie M.; Mashnik, Stepan G.

    Accurate total reaction cross section models are important to achieving reliable predictions from spallation and transport codes. The latest version of the Cascade Exciton Model (CEM) as incorporated in the code CEM03.03, and the Monte Carlo N-Particle transport code (MCNP6), both developed at Los Alamos National Laboratory (LANL), each use such cross sections. Having accurate total reaction cross section models in the intermediate energy region (50 MeV to 5 GeV) is very important for different applications, including analysis of space environments, use in medical physics, and accelerator design, to name just a few. The current inverse cross sections used inmore » the preequilibrium and evaporation stages of CEM are based on the Dostrovsky et al. model, published in 1959. Better cross section models are now available. Implementing better cross section models in CEM and MCNP6 should yield improved predictions for particle spectra and total production cross sections, among other results.« less

  10. 40 CFR Table 11 to Subpart Sssss... - Applicability of General Provisions to Subpart SSSSS

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Requirements Applies only to sources required to install and operate a THC CEMS. § 63.8(c)(7)(i)(A) CMS Requirements Applies only to sources required to install and operate a THC CEMS. § 63.8(c)(7)(i)(B) CMS Requirements Applies only to sources required to install and operate a THC CEMS. § 63.8(c)(7)(i)(C) CMS...

  11. 40 CFR Table 11 to Subpart Sssss... - Applicability of General Provisions to Subpart SSSSS

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Requirements Applies only to sources required to install and operate a THC CEMS. § 63.8(c)(7)(i)(A) CMS Requirements Applies only to sources required to install and operate a THC CEMS. § 63.8(c)(7)(i)(B) CMS Requirements Applies only to sources required to install and operate a THC CEMS. § 63.8(c)(7)(i)(C) CMS...

  12. 40 CFR Table 11 to Subpart Sssss... - Applicability of General Provisions to Subpart SSSSS

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Requirements Applies only to sources required to install and operate a THC CEMS. § 63.8(c)(7)(i)(A) CMS Requirements Applies only to sources required to install and operate a THC CEMS. § 63.8(c)(7)(i)(B) CMS Requirements Applies only to sources required to install and operate a THC CEMS. § 63.8(c)(7)(i)(C) CMS...

  13. 40 CFR Table 11 to Subpart Sssss... - Applicability of General Provisions to Subpart SSSSS

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Requirements Applies only to sources required to install and operate a THC CEMS. § 63.8(c)(7)(i)(A) CMS Requirements Applies only to sources required to install and operate a THC CEMS. § 63.8(c)(7)(i)(B) CMS Requirements Applies only to sources required to install and operate a THC CEMS. § 63.8(c)(7)(i)(C) CMS...

  14. 40 CFR Table 11 to Subpart Sssss... - Applicability of General Provisions to Subpart SSSSS

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Requirements Applies only to sources required to install and operate a THC CEMS. § 63.8(c)(7)(i)(A) CMS Requirements Applies only to sources required to install and operate a THC CEMS. § 63.8(c)(7)(i)(B) CMS Requirements Applies only to sources required to install and operate a THC CEMS. § 63.8(c)(7)(i)(C) CMS...

  15. Cytotoxicity of arctigenin and matairesinol against the T-cell lymphoma cell line CCRF-CEM.

    PubMed

    Su, Shan; Cheng, Xinlai; Wink, Michael

    2015-09-01

    Arctigenin and matairesinol possess a diversity of bioactivities. Here we investigated the cytotoxicity of arctigenin and matairesinol against a T-cell lymphoma cell line CCRF-CEM and the underlying mechanisms that have not been explored before. The cytotoxic activity was investigated using MTT assay. The cell cycle arrest and reactive oxygen species (ROS) accumulation were determined by flow cytometric analysis. The apoptosis induction was assessed using Annexin V/Propidium Iodide assay. The gene quantification analysis was measured through real-time polymerase chain reaction. Arctigenin and matairesinol exhibited significant antiproliferative activity against CCRF-CEM cells after 72 h treatment with IC50 values of 1.21 ± 0.15 μm and 4.27 ± 0.41 μm, respectively. In addition, both lignans arrest CCRF-CEM cells in the S phase. Furthermore, they could induce apoptosis in CCRF-CEM cells in a concentration- and time-dependent manner. Interestingly, the lignans differentially regulated the expression of several key genes involved in apoptosis pathways, including Bax, Bad and caspase-9. Moreover, both lignans could increase ROS levels in CCRF-CEM cells. Our study provides an insight into the potential of arctigenin and matairesinol as good candidates for the development of novel agents against T-cell lymphoma. © 2015 Royal Pharmaceutical Society.

  16. CUE: counterfeit-resistant usable eye movement-based authentication via oculomotor plant characteristics and complex eye movement patterns

    NASA Astrophysics Data System (ADS)

    Komogortsev, Oleg V.; Karpov, Alexey; Holland, Corey D.

    2012-06-01

    The widespread use of computers throughout modern society introduces the necessity for usable and counterfeit-resistant authentication methods to ensure secure access to personal resources such as bank accounts, e-mail, and social media. Current authentication methods require tedious memorization of lengthy pass phrases, are often prone to shouldersurfing, and may be easily replicated (either by counterfeiting parts of the human body or by guessing an authentication token based on readily available information). This paper describes preliminary work toward a counterfeit-resistant usable eye movement-based (CUE) authentication method. CUE does not require any passwords (improving the memorability aspect of the authentication system), and aims to provide high resistance to spoofing and shoulder-surfing by employing the combined biometric capabilities of two behavioral biometric traits: 1) oculomotor plant characteristics (OPC) which represent the internal, non-visible, anatomical structure of the eye; 2) complex eye movement patterns (CEM) which represent the strategies employed by the brain to guide visual attention. Both OPC and CEM are extracted from the eye movement signal provided by an eye tracking system. Preliminary results indicate that the fusion of OPC and CEM traits is capable of providing a 30% reduction in authentication error when compared to the authentication accuracy of individual traits.

  17. Nano-hydroxyapatite and calcium-enriched mixture for pulp capping of sound primary teeth: a randomized clinical trial.

    PubMed

    Haghgoo, Roza; Asgary, Saeed; Mashhadi Abbas, Fatemeh; Montazeri Hedeshi, Roshanak

    2015-01-01

    Nano-hydroxyapatite (NHA) has been used for regeneration of osseous defects. Calcium-enriched mixture (CEM) cement is also used for various dental treatments. This trial compared the efficacy of NHA and CEM cement for direct pulp capping (DPC) of sound primary teeth. In this randomized clinical trial with split-mouth design, after attaining informed consent, 20 sound primary canines scheduled for orthodontic extraction, were selected. After mechanical pulp exposure, the exposed site was capped with either NHA or CEM cement and then immediately restored with glass-ionomer and resin composite. The teeth were extracted after two months and examined histologically. Parameters of hard tissue bridge (HTB) formation, its type and quality as well as pulpal inflammation scores were compared between the two experimental groups. The data were analyzed using the Mann Whitney U and Fisher's exact test. The level of significance was set at 0.001. All CEM specimens showed inflammation score of 0 (less than 10%). However, in NHA group, inflammation scores of 0 (less than 10%), 1 (10%-30%) and 2 (30%-50%) were observed in 2 (20%), 4 (40%) and 4 (40%) specimens, respectively (P<0.001). HTB was formed in all CEM specimens while it was developed in 2 specimens of NHA (20%; P<0.001). All CEM specimens showed normal pulp; only two cases in NHA group (20%) demonstrated uninflamed normal pulp. CEM cement was superior to NHA as a DPC agent in terms of HTB formation and pulp inflammation scores. It is a suitable material for the DPC of primary teeth.

  18. 40 CFR Table 13 to Subpart Ddddd... - Alternative Emission Limits for New or Reconstructed Boilers and Process Heaters That Commenced...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... coal boilers designed to burn coal/solid fossil fuel a. Carbon monoxide (CO) (or CEMS) 130 ppm by... dscm per run. 3. Stokers designed to burn coal/solid fossil fuel a. CO (or CEMS) 130 ppm by volume on a... per run. 4. Fluidized bed units designed to burn coal/solid fossil fuel a. CO (or CEMS) 130 ppm by...

  19. The Future of Contrast-Enhanced Mammography.

    PubMed

    Covington, Matthew F; Pizzitola, Victor J; Lorans, Roxanne; Pockaj, Barbara A; Northfelt, Donald W; Appleton, Catherine M; Patel, Bhavika K

    2018-02-01

    The purpose of this article is to discuss facilitators of and barriers to future implementation of contrast-enhanced mammography (CEM) in the United States. CEM provides low-energy 2D mammographic images analogous to digital mammography and contrast-enhanced recombined images that allow assessment of neovascularity similar to that offered by MRI. The utilization of CEM in the United States is currently low but could increase rapidly given the many potential indications for its clinical use.

  20. Enhancing Maternal and Perinatal Health in Under-Served Remote Areas in Sub-Saharan Africa: A Tanzanian Model

    PubMed Central

    Nyamtema, Angelo S.; Mwakatundu, Nguke; Dominico, Sunday; Mohamed, Hamed; Pemba, Senga; Rumanyika, Richard; Kairuki, Clementina; Kassiga, Irene; Shayo, Allan; Issa, Omary; Nzabuhakwa, Calist; Lyimo, Chagi; van Roosmalen, Jos

    2016-01-01

    Background In Tanzania, maternal mortality ratio (MMR), unmet need for emergency obstetric care and health inequities across the country are in a critical state, particularly in rural areas. This study was established to determine the feasibility and impact of decentralizing comprehensive emergency obstetric and neonatal care (CEmONC) services in underserved rural areas using associate clinicians. Methods Ten health centres (HCs) were upgraded by constructing and equipping maternity blocks, operating rooms, laboratories, staff houses and installing solar panels, standby generators and water supply systems. Twenty-three assistant medical officers (advanced level associate clinicians), and forty-four nurse-midwives and clinical officers (associate clinicians) were trained in CEmONC and anaesthesia respectively. CEmONC services were launched between 2009 and 2012. Monthly supportive supervision and clinical audits of adverse pregnancy outcomes were introduced in 2011 in these HCs and their respective district hospitals. Findings After launching CEmONC services from 2009 to 2014 institutional deliveries increased in all upgraded rural HCs. Mean numbers of monthly deliveries increased by 151% and obstetric referrals decreased from 9% to 3% (p = 0.03) in HCs. A total of 43,846 deliveries and 2,890 caesarean sections (CS) were performed in these HCs making the mean proportion of all births in EmONC facilities of 128% and mean population-based CS rate of 9%. There were 190 maternal deaths and 1,198 intrapartum and very early neonatal deaths (IVEND) in all health facilities. Generally, health centres had statistically significantly lower maternal mortality ratios and IVEND rates than district hospitals (p < 0.00 and < 0.02 respectively). Of all deaths (maternal and IVEND) 84% to 96% were considered avoidable. Conclusions These findings strongly indicate that remotely located health centres in resource limited settings hold a great potential to increase accessibility to CEmONC services and to improve maternal and perinatal health. PMID:26986725

  1. Enhancing Maternal and Perinatal Health in Under-Served Remote Areas in Sub-Saharan Africa: A Tanzanian Model.

    PubMed

    Nyamtema, Angelo S; Mwakatundu, Nguke; Dominico, Sunday; Mohamed, Hamed; Pemba, Senga; Rumanyika, Richard; Kairuki, Clementina; Kassiga, Irene; Shayo, Allan; Issa, Omary; Nzabuhakwa, Calist; Lyimo, Chagi; van Roosmalen, Jos

    2016-01-01

    In Tanzania, maternal mortality ratio (MMR), unmet need for emergency obstetric care and health inequities across the country are in a critical state, particularly in rural areas. This study was established to determine the feasibility and impact of decentralizing comprehensive emergency obstetric and neonatal care (CEmONC) services in underserved rural areas using associate clinicians. Ten health centres (HCs) were upgraded by constructing and equipping maternity blocks, operating rooms, laboratories, staff houses and installing solar panels, standby generators and water supply systems. Twenty-three assistant medical officers (advanced level associate clinicians), and forty-four nurse-midwives and clinical officers (associate clinicians) were trained in CEmONC and anaesthesia respectively. CEmONC services were launched between 2009 and 2012. Monthly supportive supervision and clinical audits of adverse pregnancy outcomes were introduced in 2011 in these HCs and their respective district hospitals. After launching CEmONC services from 2009 to 2014 institutional deliveries increased in all upgraded rural HCs. Mean numbers of monthly deliveries increased by 151% and obstetric referrals decreased from 9% to 3% (p = 0.03) in HCs. A total of 43,846 deliveries and 2,890 caesarean sections (CS) were performed in these HCs making the mean proportion of all births in EmONC facilities of 128% and mean population-based CS rate of 9%. There were 190 maternal deaths and 1,198 intrapartum and very early neonatal deaths (IVEND) in all health facilities. Generally, health centres had statistically significantly lower maternal mortality ratios and IVEND rates than district hospitals (p < 0.00 and < 0.02 respectively). Of all deaths (maternal and IVEND) 84% to 96% were considered avoidable. These findings strongly indicate that remotely located health centres in resource limited settings hold a great potential to increase accessibility to CEmONC services and to improve maternal and perinatal health.

  2. Cellular Accumulation and Pharmacodynamic Evaluation of the Intracellular Activity of CEM-101, a Novel Fluoroketolide, against Staphylococcus aureus, Listeria monocytogenes, and Legionella pneumophila in Human THP-1 Macrophages ▿ †

    PubMed Central

    Lemaire, Sandrine; Van Bambeke, Françoise; Tulkens, Paul M.

    2009-01-01

    CEM-101 is a novel fluoroketolide with lower MICs than those of telithromycin and macrolides. Our aim was to assess the cellular accumulation and intracellular activity of CEM-101 using models developed for analyzing the pharmacokinetics and pharmacological properties of antibiotics against phagocytized bacteria. We used THP-1 macrophages and Staphylococcus aureus (ATCC 25923 [methicillin (meticillin) sensitive]), Listeria monocytogenes (strain EGD), and Legionella pneumophila (ATCC 33153). CEM-101 reached cellular-to-extracellular-concentration ratios of about 350 within 24 h (versus approximately 20, 30, and 160 for telithromycin, clarithromycin, and azithromycin, respectively). This intracellular accumulation was suppressed by incubation at a pH of ≤6 and by monensin (proton ionophore) and was unaffected by verapamil (P-glycoprotein inhibitor; twofold accumulation increase for azithromycin) or gemfibrozil. While keeping with the general properties of the macrolide antibiotics in terms of maximal efficacy (Emax; approximately 1-log10-CFU decrease compared to the postphagocytosis inoculum after a 24-h incubation), CEM-101 showed significantly greater potency against phagocytized S. aureus than telithromycin, clarithromycin, and azithromycin (for which the 50% effective concentration [EC50] and static concentrations were about 3-, 6-, and 15-fold lower, respectively). CEM-101 was also about 50-fold and 100-fold more potent than azithromycin against phagocytized L. monocytogenes and L. pneumophila, respectively. These differences in EC50s and static concentrations between drugs were minimized when data were expressed as multiples of the MIC, demonstrating the critical role of intrinsic drug activity (MIC) in eliciting the antibacterial intracellular effects, whereas accumulation per se was unimportant. CEM-101 should show enhanced in vivo potency if used at doses similar to those of the comparators tested here. PMID:19564365

  3. Cellular accumulation and pharmacodynamic evaluation of the intracellular activity of CEM-101, a novel fluoroketolide, against Staphylococcus aureus, Listeria monocytogenes, and Legionella pneumophila in human THP-1 macrophages.

    PubMed

    Lemaire, Sandrine; Van Bambeke, Françoise; Tulkens, Paul M

    2009-09-01

    CEM-101 is a novel fluoroketolide with lower MICs than those of telithromycin and macrolides. Our aim was to assess the cellular accumulation and intracellular activity of CEM-101 using models developed for analyzing the pharmacokinetics and pharmacological properties of antibiotics against phagocytized bacteria. We used THP-1 macrophages and Staphylococcus aureus (ATCC 25923 [methicillin (meticillin) sensitive]), Listeria monocytogenes (strain EGD), and Legionella pneumophila (ATCC 33153). CEM-101 reached cellular-to-extracellular-concentration ratios of about 350 within 24 h (versus approximately 20, 30, and 160 for telithromycin, clarithromycin, and azithromycin, respectively). This intracellular accumulation was suppressed by incubation at a pH of < or = 6 and by monensin (proton ionophore) and was unaffected by verapamil (P-glycoprotein inhibitor; twofold accumulation increase for azithromycin) or gemfibrozil. While keeping with the general properties of the macrolide antibiotics in terms of maximal efficacy (Emax; approximately 1-log10-CFU decrease compared to the postphagocytosis inoculum after a 24-h incubation), CEM-101 showed significantly greater potency against phagocytized S. aureus than telithromycin, clarithromycin, and azithromycin (for which the 50% effective concentration [EC50] and static concentrations were about 3-, 6-, and 15-fold lower, respectively). CEM-101 was also about 50-fold and 100-fold more potent than azithromycin against phagocytized L. monocytogenes and L. pneumophila, respectively. These differences in EC50s and static concentrations between drugs were minimized when data were expressed as multiples of the MIC, demonstrating the critical role of intrinsic drug activity (MIC) in eliciting the antibacterial intracellular effects, whereas accumulation per se was unimportant. CEM-101 should show enhanced in vivo potency if used at doses similar to those of the comparators tested here.

  4. Impact of climate change on electricity systems and markets

    NASA Astrophysics Data System (ADS)

    Chandramowli, Shankar N.

    Climate change poses a serious threat to human welfare. There is now unequivocal scientific evidence that human actions are the primary cause of climate change. The principal climate forcing factor is the increasing accumulation of atmospheric carbon dioxide (CO2) due to combustion of fossil fuels for transportation and electricity generation. Generation of electricity account for nearly one-third of the greenhouse (GHG) emissions globally (on a CO2-equivalent basis). Any kind of economy-wide mitigation or adaptation effort to climate change must have a prominent focus on the electric power sector. I have developed a capacity expansion model for the power sector called LP-CEM (Linear Programming based Capacity Expansion Model). LP-CEM incorporates both the long-term climate change effects and the state/regional-level macroeconomic trends. This modeling framework is demonstrated for the electric power system in the Northeast region of United States. Some of the methodological advances introduced in this research are: the use of high-resolution temperature projections in a power sector capacity expansion model; the incorporation of changes in sectoral composition of electricity demand over time; the incorporation of the effects of climate change and variability on both the demand and supply-side of power sector using parameters estimated in the literature; and an inter-model coupling link with a macroeconomic model to account for price elasticity of demand and other effects on the broader macro-economy. LP-CEM-type models can be of use to state/regional level policymakers to plan for future mitigation and adaptation measures for the electric power sector. From the simulation runs, it is shown that scenarios with climate change effects and with high economic growth rates have resulted in higher capacity addition, optimal supply costs, wholesale/retail prices and total ratepayers' costs. LP-CEM is also adapted to model the implications of the proposed Clean Power Plan (Section 111 (d)) rules for the U.S. Northeast region. This dissertation applies an analytical model and an optimization model to investigate the implications of co-implementing an emission cap and an RPS policy for this region. A simplified analytical model of LP-CEM is specified and the first order optimality conditions are derived. The results from this analytical model are corroborated by running LP-CEM simulations under different carbon cap and RPS policy assumptions. A combination of these policies is shown to have a long-term beneficial effect for the final ratepayers in the region. This research conceptually explores the future implications of climate change and extreme weather events on the regional electricity market framework. The significant findings from this research and future policy considerations are discussed in the conclusion chapter.

  5. Enhanced Imaging of Specific Cell-Surface Glycosylation Based on Multi-FRET.

    PubMed

    Yuan, Baoyin; Chen, Yuanyuan; Sun, Yuqiong; Guo, Qiuping; Huang, Jin; Liu, Jianbo; Meng, Xiangxian; Yang, Xiaohai; Wen, Xiaohong; Li, Zenghui; Li, Lie; Wang, Kemin

    2018-05-15

    Cell-surface glycosylation contains abundant biological information that reflects cell physiological state, and it is of great value to image cell-surface glycosylation to elucidate its functions. Here we present a hybridization chain reaction (HCR)-based multifluorescence resonance energy transfer (multi-FRET) method for specific imaging of cell-surface glycosylation. By installing donors through metabolic glycan labeling and acceptors through aptamer-tethered nanoassemblies on the same glycoconjugate, intramolecular multi-FRET occurs due to near donor-acceptor distance. Benefiting from amplified effect and spatial flexibility of the HCR nanoassemblies, enhanced multi-FRET imaging of specific cell-surface glycosylation can be obtained. With this HCR-based multi-FRET method, we achieved obvious contrast in imaging of protein-specific GalNAcylation on 7211 cell surfaces. In addition, we demonstrated the general applicability of this method by visualizing the protein-specific sialylation on CEM cell surfaces. Furthermore, the expression changes of CEM cell-surface protein-specific sialylation under drug treatment was accurately monitored. This developed imaging method may provide a powerful tool in researching glycosylation functions, discovering biomarkers, and screening drugs.

  6. Channel electron multipliers - Detection efficiencies with opaque MgF2 photocathodes at XUV wavelengths

    NASA Technical Reports Server (NTRS)

    Lapson, L. B.; Timothy, J. G.

    1976-01-01

    Detection efficiencies of channel electron multipliers (CEM) with opaque MgF2 photocathodes obtained in the extreme ultraviolet (XUV), 44 A to 990 A, are reported. A stable highly efficient response is reported for that interval, with no adverse effects on CEM performance. Efficiencies twice those of uncoated CEMs are obtained for 50 A to 350 A. The Mullard B419BL and Galileo 4510WL single-stage cone-cathode CEMs were used in the experiments. A rare-gas double ionization chamber was employed as absolute standard detector for 406 A to 990 A, and a flow Geiger counter filled with 96% argon and 4% isobutane for 44 A to 256 A. Absolute detection efficiencies are 10% higher from 67 A to 990 A when photocathodes are illuminated at an angle of incidence 45 deg. The photocathodes suffered no loss of response in storage (in vacuum or air) after an initial aging period. Effects of scattered UV radiation are greatly reduced when MgF2-coated CEMs are used in the XUV.

  7. CEMS: Building a Cloud-Based Infrastructure to Support Climate and Environmental Data Services

    NASA Astrophysics Data System (ADS)

    Kershaw, P. J.; Curtis, M.; Pechorro, E.

    2012-04-01

    CEMS, the facility for Climate and Environmental Monitoring from Space, is a new joint collaboration between academia and industry to bring together their collective expertise to support research into climate change and provide a catalyst for growth in related Earth Observation (EO) technologies and services in the commercial sector. A recent major investment by the UK Space Agency has made possible the development of a dedicated facility at ISIC, the International Space Innovation Centre at Harwell in the UK. CEMS has a number of key elements: the provision of access to large-volume EO and climate datasets co-located with high performance computing facilities; a flexible infrastructure to support the needs of research projects in the academic community and new business opportunities for commercial companies. Expertise and tools for scientific data quality and integrity are another essential component, giving users confidence and transparency in its data, services and products. Central to the development of this infrastructure is the utilisation of cloud-based technology: multi-tenancy and the dynamic provision of resources are key characteristics to exploit in order to support the range of organisations using the facilities and the varied use cases. The hosting of processing services and applications next to the data within the CEMS facility is another important capability. With the expected exponential increase in data volumes within the climate science and EO domains it is becoming increasingly impracticable for organisations to retrieve this data over networks and provide the necessary storage. Consider for example, the factor of o20 increase in data volumes expected for the ESA Sentinel missions over the equivalent Envisat instruments. We explore the options for the provision of a hybrid community/private cloud looking at offerings from the commercial sector and developments in the Open Source community. Building on this virtualisation layer, a further core services tier will support and serve applications as part of a service oriented architecture. We consider the constituent services in this layer to support access to the data, data processing and the orchestration of workflows.

  8. B7-H4 as a Target for Breast Cancer Immunotherapy

    DTIC Science & Technology

    2012-06-01

    lymphoma and leukemia cell lines. CEM, Karpas 299, and TLBR -1, cell lines derived from acute T-cell lymphoblastic leukemia, large cell anaplastic...Accomplishments  Generation of human B7-H4-Fc fusion protein (antigen).  Discovery of a B7-H4 receptor on CEM, Karpas 299, and TLBR -1 cell lines...CEM Karpas 299 TLBR -1 Jurkat B7-H4R Figure 3. B7-H4 binding to human T-cell lymphoma cell lines. Red

  9. 38 CFR 39.31 - Preapplication requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., Veterans Cemetery Grants Service, through http://www.cem.va.gov/cem/scg_grants.asp. (b) No detailed... cemetery buildings, based on VA guidance on the net and gross square footage standards for cemetery...

  10. Channel electron multiplier operated on a sounding rocket without a cryogenic vacuum pump from 120 - 75 km altitude

    NASA Astrophysics Data System (ADS)

    Dickson, S.; Gausa, M. A.; Robertson, S. H.; Sternovsky, Z.

    2012-12-01

    We demonstrate that a channel electron multiplier (CEM) can be operated on a sounding rocket in the pulse-counting mode from 120 km to 75 km altitude without the cryogenic evacuation used in the past. Evacuation of the CEM is provided only by aerodynamic flow around the rocket. This demonstration is motivated by the need for additional flights of mass spectrometers to clarify the fate of metallic compounds and ions ablated from micrometeorites and their possible role in the nucleation of noctilucent clouds. The CEMs were flown as guest instruments on the two sounding rockets of the CHAMPS (CHarge And mass of Meteoritic smoke ParticleS) rocket campaign which were launched into the mesosphere in October 2011 from Andøya Rocket Range, Norway. Modeling of the aerodynamic flow around the payload with Direct Simulation Monte-Carlo (DSMC) code showed that the pressure is reduced below ambient in the void beneath an aft-facing surface. An enclosure containing the CEM was placed above an aft-facing deck and a valve was opened on the downleg to expose the CEM to the aerodynamically evacuated region below. The CEM operated successfully from apogee down to ~75 km. A Pirani gauge confirmed pressures reduced to as low as 20% of ambient with the extent of reduction dependent upon altitude and velocity. Additional DSMC simulations indicate that there are alternate payload designs with improved aerodynamic pumping for forward mounted instruments such as mass spectrometers.

  11. In Vitro Sealing Properties of Calcium-Enriched Mixture and Mineral Trioxide Aggregate Orifice Barriers during Intra-Coronal Bleaching

    PubMed Central

    Moghadam, Negar; Abdollahi, Amir Ardalan; Aghabalayi Fakhim, Hoda; Borna, Zahra

    2017-01-01

    Introduction: This study aimed at evaluating the sealing properties of calcium-enriched mixture (CEM) compared to mineral trioxide aggregate (MTA) as a cervical barriers in intra-coronal bleaching. Methods and Materials: In this in vitro study, endodontic treatment was performed on 60 extracted human incisors and canines without canal calcification, caries, restorations, resorption or cracks. The teeth were then randomly divided into two experimental groups and two control groups (n=15). Then, CEM cement and MTA were applied as 3-mm intra-orifice barriers in the test groups; a mixture of sodium perborate and 30% hydrogen peroxide bleaching agents were placed within the pulp chamber for one week. Dye penetration method was used to evaluate the sealing ability of agents. Statistical analysis was performed using SPSS software. The Kendall coefficient was used to evaluate inter-observer agreement. The chi-squared test was used for statistical analysis. Results: The results showed that the penetration rates of CEM and MTA were the same as positive control group, with no significant differences (P=0.673 and P=0.408, respectively). However, there was a significant difference between the negative control group and CEM and MTA groups (P=0.001 for both groups). In addition, the sealing ability of MTA and CEM cement were not significantly different (P=0.682). Conclusion: During intra-coronal bleaching procedures CEM cement can be used as a cervical barrier with sealing properties comparable to that of MTA. PMID:28512492

  12. In Vitro Sealing Properties of Calcium-Enriched Mixture and Mineral Trioxide Aggregate Orifice Barriers during Intra-Coronal Bleaching.

    PubMed

    Moghadam, Negar; Abdollahi, Amir Ardalan; Aghabalayi Fakhim, Hoda; Borna, Zahra

    2017-01-01

    This study aimed at evaluating the sealing properties of calcium-enriched mixture (CEM) compared to mineral trioxide aggregate (MTA) as a cervical barriers in intra-coronal bleaching. In this in vitro study, endodontic treatment was performed on 60 extracted human incisors and canines without canal calcification, caries, restorations, resorption or cracks. The teeth were then randomly divided into two experimental groups and two control groups ( n =15). Then, CEM cement and MTA were applied as 3-mm intra-orifice barriers in the test groups; a mixture of sodium perborate and 30% hydrogen peroxide bleaching agents were placed within the pulp chamber for one week. Dye penetration method was used to evaluate the sealing ability of agents. Statistical analysis was performed using SPSS software. The Kendall coefficient was used to evaluate inter-observer agreement. The chi-squared test was used for statistical analysis. The results showed that the penetration rates of CEM and MTA were the same as positive control group, with no significant differences ( P =0.673 and P =0.408, respectively). However, there was a significant difference between the negative control group and CEM and MTA groups ( P =0.001 for both groups). In addition, the sealing ability of MTA and CEM cement were not significantly different ( P =0.682). During intra-coronal bleaching procedures CEM cement can be used as a cervical barrier with sealing properties comparable to that of MTA.

  13. Estimates of Power Plant NOx Emissions and Lifetimes from OMI NO2 Satellite Retrievals

    NASA Technical Reports Server (NTRS)

    de Foy, Benjamin; Lu, Zifeng; Streets, David G.; Lamsal, Lok N.; Duncan, Bryan N.

    2015-01-01

    Isolated power plants with well characterized emissions serve as an ideal test case of methods to estimate emissions using satellite data. In this study we evaluate the Exponentially-Modified Gaussian (EMG) method and the box model method based on mass balance for estimating known NOx emissions from satellite retrievals made by the Ozone Monitoring Instrument (OMI). We consider 29 power plants in the USA which have large NOx plumes that do not overlap with other sources and which have emissions data from the Continuous Emission Monitoring System (CEMS). This enables us to identify constraints required by the methods, such as which wind data to use and how to calculate background values. We found that the lifetimes estimated by the methods are too short to be representative of the chemical lifetime. Instead, we introduce a separate lifetime parameter to account for the discrepancy between estimates using real data and those that theory would predict. In terms of emissions, the EMG method required averages from multiple years to give accurate results, whereas the box model method gave accurate results for individual ozone seasons.

  14. Hg0 and HgCl2 Reference Gas Standards: ?NIST Traceability ...

    EPA Pesticide Factsheets

    EPA and NIST have collaborated to establish the necessary procedures for establishing the required NIST traceability of commercially-provided Hg0 and HgCl2 reference generators. This presentation will discuss the approach of a joint EPA/NIST study to accurately quantify the true concentrations of Hg0 and HgCl2 reference gases produced from high quality, NIST-traceable, commercial Hg0 and HgCl2 generators. This presentation will also discuss the availability of HCl and Hg0 compressed reference gas standards as a result of EPA's recently approved Alternative Methods 114 and 118. Gaseous elemental mercury (Hg0) and oxidized mercury (HgCl2) reference standards are integral to the use of mercury continuous emissions monitoring systems (Hg CEMS) for regulatory compliance emissions monitoring. However, a quantitative disparity of approximately 7-10% has been observed between commercial Hg0 and HgCl2 reference gases which currently limits the use of (HgCl2) reference gas standards. Resolving this disparity would enable the expanded use of (HgCl2) reference gas standards for regulatory compliance purposes.

  15. A preliminary report on histological outcome of pulpotomy with endodontic biomaterials vs calcium hydroxide.

    PubMed

    Nosrat, Ali; Peimani, Ali; Asgary, Saeed

    2013-11-01

    The purpose of the study was to evaluate human dental pulp response to pulpotomy with calcium hydroxide (CH), mineral trioxide aggregate (MTA), and calcium enriched mixture (CEM) cement. A total of nine erupted third molars were randomly assigned to each pulpotomy group. The same clinician performed full pulpotomies and coronal restorations. The patients were followed clinically for six months; the teeth were then extracted and prepared for histological assessments. The samples were blindly assessed by an independent observer for pulp vitality, pulp inflammation, and calcified bridge formation. All patients were free of clinical signs/symptoms of pulpal/periradicular diseases during the follow up period. In CH group, one tooth had necrotic radicular pulp; other two teeth in this group had vital uninflamed pulps with complete dentinal bridge formation. In CEM cement and MTA groups all teeth had vital uninflamed radicular pulps. A complete dentinal bridge was formed beneath CEM cement and MTA in all roots. Odontoblast-like cells were present beneath CEM cement and MTA in all samples. This study revealed that CEM cement and MTA were reliable endodontic biomaterials in full pulpotomy treatment. In contrast, the human dental pulp response to CH might be unpredictable.

  16. CEM-Consumer Exposure Model Download and Install Instructions

    EPA Pesticide Factsheets

    CEM contains a combination of models and default parameters which are used to estimate inhalation, dermal, and oral exposures to consumer products and articles for a wide variety of product and article use categories.

  17. Object-Oriented Multi-Disciplinary Design, Analysis, and Optimization Tool

    NASA Technical Reports Server (NTRS)

    Pak, Chan-gi

    2011-01-01

    An Object-Oriented Optimization (O3) tool was developed that leverages existing tools and practices, and allows the easy integration and adoption of new state-of-the-art software. At the heart of the O3 tool is the Central Executive Module (CEM), which can integrate disparate software packages in a cross platform network environment so as to quickly perform optimization and design tasks in a cohesive, streamlined manner. This object-oriented framework can integrate the analysis codes for multiple disciplines instead of relying on one code to perform the analysis for all disciplines. The CEM was written in FORTRAN and the script commands for each performance index were submitted through the use of the FORTRAN Call System command. In this CEM, the user chooses an optimization methodology, defines objective and constraint functions from performance indices, and provides starting and side constraints for continuous as well as discrete design variables. The structural analysis modules such as computations of the structural weight, stress, deflection, buckling, and flutter and divergence speeds have been developed and incorporated into the O3 tool to build an object-oriented Multidisciplinary Design, Analysis, and Optimization (MDAO) tool.

  18. CEM V based special cementitious materials investigated by means of SANS method. Preliminary results

    NASA Astrophysics Data System (ADS)

    Dragolici, A. C.; Balasoiu, M.; Orelovich, O. L.; Ionascu, L.; Nicu, M.; Soloviov, D. V.; Kuklin, A. I.; Lizunov, E. I.; Dragolici, F.

    2017-05-01

    The management of the radioactive waste assume the conditioning in a cement matrix as an embedding, stable, disposal material. Cement matrix is the first and most important engineering barrier against the migration in the environment of the radionuclides contained in the waste packages. Knowing how the microstructure develops is therefore desirable in order to assess the compatibility of radioactive streams with cement and predict waste form performance during storage and disposal. For conditioning wastes containing radioactive aluminum new formulas of low basicity cements, using coatings as a barrier between the metal and the conditioning environment or introducing a corrosion inhibitor in the matrix system are required. Preliminary microstructure investigation of such improved CEM V based cement matrix is reported.

  19. A Graphene Oxide-Based Fluorescent Aptasensor for the Turn-on Detection of CCRF-CEM.

    PubMed

    Tan, Jie; Lai, Zongqiang; Zhong, Liping; Zhang, Zhenghua; Zheng, Rong; Su, Jing; Huang, Yong; Huang, Panpan; Song, Hui; Yang, Nuo; Zhou, Sufang; Zhao, Yongxiang

    2018-04-01

    A convenient, low-cost, and highly sensitive fluorescent aptasensor for detection of leukemia has been developed based on graphene oxide-aptamer complex (GO-apt). Graphene oxide (GO) can absorb carboxyfluorescein-labeled Sgc8 aptamer (FAM-apt) by π-π stacking and quench the fluorescence through fluorescence resonance energy transfer (FRET). In the absence of Sgc8 target cell CCRF-CEM, the fluorescence is almost all quenched. Conversely, when the CCRF-CEM cells are added, the quenched fluorescence can be recovered rapidly and significantly. Therefore, based on the change of fluorescence signals, we can detect the number of CCRF-CEM cells in a wide range from 1 × 10 2 to 1 × 10 7  cells/mL with a limit of detection (LOD) of 10 cells/mL. Therefore, this strategy of graphene oxide-based fluorescent aptasensor may be promising for the detection of cancer.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Knospe, W.H.; Husseini, S.G.

    Cellulose ester membranes (CEM) were coated with stromal cells from murine bone or bone marrow irradiated in vitro with 1000, 2000, or 4000 rad and then implanted i.p. in CAF1 mice for periods of six and 12 months. CEM coated with stromal cells from bone showed excellent regeneration of bone and hematopoiesis after 1000 rad in vitro irradiation. After 2000 rad, hematopoietic and bone regeneration was reduced by about 50%, and after 4000 rad it was completely absent in CEM coated with stromal cells from bone. CEM coated with stromal cells from bone marrow showed no regeneration of hematopoiesis ormore » bone after 1000, 2000, and 4000 rad in vitro irradiation and residence i.p. for six and 12 months. These results indicate that regeneration of the hematopoietic microenvironment is dependent upon living stromal cells. A difference in radiation sensitivity is demonstrated between stromal cells from bone and from bone marrow.« less

  1. Overcoming Geometry-Induced Stiffness with IMplicit-Explicit (IMEX) Runge-Kutta Algorithms on Unstructured Grids with Applications to CEM, CFD, and CAA

    NASA Technical Reports Server (NTRS)

    Kanevsky, Alex

    2004-01-01

    My goal is to develop and implement efficient, accurate, and robust Implicit-Explicit Runge-Kutta (IMEX RK) methods [9] for overcoming geometry-induced stiffness with applications to computational electromagnetics (CEM), computational fluid dynamics (CFD) and computational aeroacoustics (CAA). IMEX algorithms solve the non-stiff portions of the domain using explicit methods, and isolate and solve the more expensive stiff portions using implicit methods. Current algorithms in CEM can only simulate purely harmonic (up to lOGHz plane wave) EM scattering by fighter aircraft, which are assumed to be pure metallic shells, and cannot handle the inclusion of coatings, penetration into and radiation out of the aircraft. Efficient MEX RK methods could potentially increase current CEM capabilities by 1-2 orders of magnitude, allowing scientists and engineers to attack more challenging and realistic problems.

  2. Raytheon and NREL Validated Advanced Microgrid System for U.S. Marines |

    Science.gov Websites

    Schroeder Microgrids can work independently of the traditional grid, making them effective sources of backup work. It truly felt like history in the making." - Mick Wasco, PE, CEM Installation Energy Manager

  3. Constrained energy minimization applied to apparent reflectance and single-scattering albedo spectra: a comparison

    NASA Astrophysics Data System (ADS)

    Resmini, Ronald G.; Graver, William R.; Kappus, Mary E.; Anderson, Mark E.

    1996-11-01

    Constrained energy minimization (CEM) has been applied to the mapping of the quantitative areal distribution of the mineral alunite in an approximately 1.8 km2 area of the Cuprite mining district, Nevada. CEM is a powerful technique for rapid quantitative mineral mapping which requires only the spectrum of the mineral to be mapped. A priori knowledge of background spectral signatures is not required. Our investigation applies CEM to calibrated radiance data converted to apparent reflectance (AR) and to single scattering albedo (SSA) spectra. The radiance data were acquired by the 210 channel, 0.4 micrometers to 2.5 micrometers airborne Hyperspectral Digital Imagery Collection Experiment sensor. CEM applied to AR spectra assumes linear mixing of the spectra of the materials exposed at the surface. This assumption is likely invalid as surface materials, which are often mixtures of particulates of different substances, are more properly modeled as intimate mixtures and thus spectral mixing analyses must take account of nonlinear effects. One technique for approximating nonlinear mixing requires the conversion of AR spectra to SSA spectra. The results of CEM applied to SSA spectra are compared to those of CEM applied to AR spectra. The occurrence of alunite is similar though not identical to mineral maps produced with both the SSA and AR spectra. Alunite is slightly more widespread based on processing with the SSA spectra. Further, fractional abundances derived from the SSA spectra are, in general, higher than those derived from AR spectra. Implications for the interpretation of quantitative mineral mapping with hyperspectral remote sensing data are discussed.

  4. Capturing the Impact of Storage and Other Flexible Technologies on Electric System Planning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hale, Elaine; Stoll, Brady; Mai, Trieu

    Power systems of the future are likely to require additional flexibility. This has been well studied from an operational perspective, but has been more difficult to incorporate into capacity expansion models (CEMs) that study investment decisions on the decadal scale. There are two primary reasons for this. First, the necessary input data, including cost and resource projections, for flexibility options like demand response and storage are significantly uncertain. Second, it is computationally difficult to represent both investment and operational decisions in detail, the latter being necessary to properly value system flexibility, in CEMs for realistically sized systems. In this work,more » we extend a particular CEM, NREL's Resource Planning Model (RPM), to address the latter issue by better representing variable generation impacts on operations, and then adding two flexible technologies to RPM's suite of investment decisions: interruptible load and utility-scale storage. This work does not develop full suites of input data for these technologies, but is rather methodological and exploratory in nature. We thus exercise these new investment decisions in the context of exploring price points and value streams needed for significant deployment in the Western Interconnection by 2030. Our study of interruptible load finds significant variation by location, year, and overall system conditions. Some locations find no system need for interruptible load even with low costs, while others build the most expensive resources offered. System needs can include planning reserve capacity needs to ensure resource adequacy, but there are also particular cases in which spinning reserve requirements drive deployment. Utility-scale storage is found to require deep cost reductions to achieve wide deployment and is found to be more valuable in some locations with greater renewable deployment. Differences between more solar- and wind-reliant regions are also found: Storage technologies with lower energy capacities are deployed to support solar deployment, and higher energy capacity technologies support wind. Finally, we identify potential future research and areas of improvement to build on this initial analysis.« less

  5. 40 CFR 98.167 - Records that must be retained.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... CEMS is not used to measure GHG emissions. (2) Fossil fuel consumption, when, pursuant to § 98.33(e), the owner or operator of a unit that uses CEMS to quantify CO2 emissions and that combusts both fossil...

  6. Locomotive Crash Energy Management Coupling Tests

    DOT National Transportation Integrated Search

    2018-04-18

    This paper describes the results of the CEM equipped locomotive coupling tests. In this set of tests, a moving CEM locomotive was coupled to a standing cab car. The primary objective was to demonstrate the robustness of the PBC design and determine t...

  7. Development of a cell microarray chip for detection of circulating tumor cells

    NASA Astrophysics Data System (ADS)

    Yamamura, S.; Yatsushiro, S.; Abe, K.; Baba, Y.; Kataoka, M.

    2012-03-01

    Detection of circulating tumor cells (CTCs) in the peripheral blood of metastatic cancer patients has clinical significance in earlier diagnosis of metastases. In this study, a novel cell microarray chip for accurate and rapid detection of tumor cells from human leukocytes was developed. The chip with 20,944 microchambers (105 μm diameter and 50 μm depth) was made from polystyrene, and the surface was rendered to hydrophilic by means of reactive-ion etching, which led to the formation of mono-layers of leukocytes on the microchambers. As the model of CTCs detection, we spiked human bronchioalveolar carcinoma (H1650) cells into human T lymphoblastoid leukemia (CEM) cells suspension and detected H1650 cells using the chip. A CEM suspension contained with H1650 cells was dispersed on the chip surface, followed by 10 min standing to allow the cells to settle down into the microchambers. About 30 CEM cells were accommodated in each microchamber, over 600,000 CEM cells in total being on a chip. We could detect 1 H1650 cell per 106 CEM cells on the microarray by staining with fluorescence-conjugated antibody (Anti-Cytokeratin) and cell membrane marker (DiD). Thus, this cell microarray chip has highly potential to be a novel tool of accurate and rapid detection of CTCs.

  8. A preliminary report on histological outcome of pulpotomy with endodontic biomaterials vs calcium hydroxide

    PubMed Central

    Peimani, Ali; Asgary, Saeed

    2013-01-01

    Objectives The purpose of the study was to evaluate human dental pulp response to pulpotomy with calcium hydroxide (CH), mineral trioxide aggregate (MTA), and calcium enriched mixture (CEM) cement. Materials and Methods A total of nine erupted third molars were randomly assigned to each pulpotomy group. The same clinician performed full pulpotomies and coronal restorations. The patients were followed clinically for six months; the teeth were then extracted and prepared for histological assessments. The samples were blindly assessed by an independent observer for pulp vitality, pulp inflammation, and calcified bridge formation. Results All patients were free of clinical signs/symptoms of pulpal/periradicular diseases during the follow up period. In CH group, one tooth had necrotic radicular pulp; other two teeth in this group had vital uninflamed pulps with complete dentinal bridge formation. In CEM cement and MTA groups all teeth had vital uninflamed radicular pulps. A complete dentinal bridge was formed beneath CEM cement and MTA in all roots. Odontoblast-like cells were present beneath CEM cement and MTA in all samples. Conclusions This study revealed that CEM cement and MTA were reliable endodontic biomaterials in full pulpotomy treatment. In contrast, the human dental pulp response to CH might be unpredictable. PMID:24303358

  9. μ-Opioid Receptor-Mediated Inhibition of Intercalated Neurons and Effect on Synaptic Transmission to the Central Amygdala.

    PubMed

    Blaesse, Peter; Goedecke, Lena; Bazelot, Michaël; Capogna, Marco; Pape, Hans-Christian; Jüngling, Kay

    2015-05-13

    The amygdala is a key region for the processing of information underlying fear, anxiety, and fear extinction. Within the local neuronal networks of the amygdala, a population of inhibitory, intercalated neurons (ITCs) modulates the flow of information among various nuclei of amygdala, including the basal nucleus (BA) and the centromedial nucleus (CeM) of the amygdala. These ITCs have been shown to be important during fear extinction and are target of a variety of neurotransmitters and neuropeptides. Here we provide evidence that the activation of μ-opioid receptors (MORs) by the specific agonist DAMGO ([D-Ala2,N-Me-Phe4,Gly5-ol]-Enkephalin) hyperpolarizes medially located ITCs (mITCs) in acute brain slices of mice. Moreover, we use whole-cell patch-clamp recordings in combination with local electrical stimulation or glutamate uncaging to analyze the effect of MOR activation on local microcircuits. We show that the GABAergic transmission between mITCs and CeM neurons is attenuated by DAMGO, whereas the glutamatergic transmission on CeM neurons and mITCs is unaffected. Furthermore, MOR activation induced by theta burst stimulation in BA suppresses plastic changes of feedforward inhibitory transmission onto CeM neurons as revealed by the MOR antagonist CTAP d-Phe-Cys-Tyr-d-Trp-Arg-Thr-Pen-Thr-NH2. In summary, the mITCs constitute a target for the opioid system, and therefore, the activation of MOR in ITCs might play a central role in the modulation of the information processing between the basolateral complex of the amygdala and central nuclei of the amygdala. Copyright © 2015 Blaesse, Goedecke et al.

  10. Inhibition of spinal reflexes by paramedian reticular nucleus.

    PubMed

    Chai, C Y; Lin, Y F; Wang, H Y; Wu, W C; Yen, C T; Kuo, J S; Wayner, M J

    1990-10-01

    The inhibitory actions of the paramedian reticular nucleus (PRN), and its neighbouring structures, i.e., midline raphe nuclei (MRN) and dorsal medullary depressor area (DMD) on the knee jerk (KnJ) and crossed extension movement (CEM) induced by central sciatic stimulation and on the L5 ventral root response (EVRR) evoked by central tibial stimulation, were studied in cats under urethane (400 mg/kg) and alpha-chloralose (40 mg/kg) anesthesia alone, IP or further paralyzed with atracurium besylate (0.5 mg/kg/30 min), IV. Electrical stimulation of the above areas with rectangular pulses (80 Hz, 1.0 msec, 100-200 microA) decreased systemic arterial blood pressure (SAP) in an average value of: 36 +/- 3 mmHg for PRN; 19 +/- 2 mmHg for MRN; and 23 +/- 3 mmHg for DMD. The KnJ and CEM were almost completely suppressed by simultaneous PRN stimulation. The EVRR, including mono- and polysynaptic spinal reflexes with transmission velocity from 10 to 60 m/sec or above, were also suppressed. MRN stimulation only inhibited the KnJ, CEM and polysynaptic spinal reflexes with transmission velocities between 25 and 60 m/sec, but facilitated spinal reflexes with conduction velocities below 10 m/sec. On the other hand, DMD stimulation resulted in small suppression of KnJ, CEM and inhibition of polysynaptic spinal reflexes with conduction velocities between 25 and 60 m/sec. Even though MRN and DMD partially inhibited polysynaptic spinal reflexes, the magnitude of such inhibition was much smaller than that produced by PRN (-20% and -22% vs. -48%). The above-mentioned PRN effects on SAP and EVRR persisted in chronic animals decerebellated 9-12 days before.(ABSTRACT TRUNCATED AT 250 WORDS)

  11. Compact self-aligning assemblies with refractive microlens arrays made by contactless embossing

    NASA Astrophysics Data System (ADS)

    Schulze, Jens; Ehrfeld, Wolfgang; Mueller, Holger; Picard, Antoni

    1998-04-01

    The hybrid integration of microlenses and arrays of microlenses in micro-optical systems is simplified using contactless embossing of microlenses (CEM) in combination with LIGA microfabrication. CEM is anew fabrication technique for the production of precise refractive microlens arrays. A high precision matrix of holes made by LIGA technique is used as a compression molding tool to form the microlenses. The tool is pressed onto a thermoplastic sample which is heated close to the glass transformation temperature of the material. The material bulges into the openings of the molding tool due to the applied pressure and forms lens-like spherical structures. The name refers to the fact that the surface of the microlens does not get in contact with the compression molding tool during the shaping process and optical quality of the surface is maintained. Microlenses and arrays of microlenses with lens diameters from 30 micrometers up to 700 micrometers and numerical aperture values of up to 0.25 have been fabricated in different materials. Cost-effectiveness in the production process, excellent optical performance and the feature of easy replication are the main advantages of this technique. The most promising feature of this method is the possibility to obtain self- aligned assemblies then can be further integrated into a micro-optical bench setup. The CEM fabrication method in combination with LIGA microfabrication considerably enhances the hybrid integration in micro-optical devices which results in a more cost-effective production of compact micro-opto-electro-mechanical systems.

  12. Analysis of collision safety associated with CEM and conventional cars mixed within a consist

    DOT National Transportation Integrated Search

    2003-11-16

    collision dynamics model of a passenger train-to-passenger train collision has been developed to simulate the potential safety hazards and benefits associated with mixing conventional and crash energy management (CEM) cars within a consist. This pape...

  13. Validating Ultrasound-based HIFU Lesion-size Monitoring Technique with MR Thermometry and Histology

    NASA Astrophysics Data System (ADS)

    Zhou, Shiwei; Petruzzello, John; Anand, Ajay; Sethuraman, Shriram; Azevedo, Jose

    2010-03-01

    In order to control and monitor HIFU lesions accurately and cost-effectively in real-time, we have developed an ultrasound-based therapy monitoring technique using acoustic radiation force to track the change in tissue mechanical properties. We validate our method with concurrent MR thermometry and histology. Comparison studies have been completed on in-vitro bovine liver samples. A single-element 1.1 MHz focused transducer was used to deliver HIFU and produce acoustic radiation force (ARF). A 5 MHz single-element transducer was placed co-axially with the HIFU transducer to acquire the RF data, and track the tissue displacement induced by ARF. During therapy, the monitoring procedure was interleaved with HIFU. MR thermometry (Philips Panorama 1T system) and ultrasound monitoring were performed simultaneously. The tissue temperature and thermal dose (CEM43 = 240 mins) were computed from the MR thermometry data. The tissue displacement induced by the acoustic radiation force was calculated from the ultrasound RF data in real-time using a cross-correlation based method. A normalized displacement difference (NDD) parameter was developed and calibrated to estimate the lesion size. The lesion size estimated by the NDD was compared with both MR thermometry prediction and the histology analysis. For lesions smaller than 8mm, the NDD-based lesion monitoring technique showed very similar performance as MR thermometry. The standard deviation of lesion size error is 0.66 mm, which is comparable to MR thermal dose contour prediction (0.42 mm). A phased array is needed for tracking displacement in 2D and monitoring lesion larger than 8 mm. The study demonstrates the potential of our ultrasound based technique to achieve precise HIFU lesion control through real-time monitoring. The results compare well with histology and an established technique like MR Thermometry. This approach provides feedback control in real-time to terminate therapy when a pre-determined lesion size is achieved, and can be extended to 2D and implemented on commercial ultrasound scanner systems.

  14. Degradation of the Giant Magnetoresistance in Fe/Cr Multilayers Due to Ar-Ion Beam Mixing

    NASA Astrophysics Data System (ADS)

    Kopcewicz, M.; Stobiecki, F.; Jagielski, J.; Szymański, B.; Schmidt, M.; Kalinowska, J.

    2002-12-01

    The influence of 200 keV Ar-ion irradiation on the interlayer coupling in the Fe/Cr multilayer system exhibiting the giant magnetoresistance effect (GMR) is studied by conversion electron Mössbauer spectroscopy (CEMS), VSM hysteresis loops, magnetoresistivity and electric resistivity measurements and supplemented by the small-angle X-ray diffraction (SAXRD). The increase of Ar ion dose causes an increase of interface roughness, as evidenced by the increase of the Fe step-sites detected by CEMS as a result of which the GMR gradually decreases and vanishes at doses exceeding 1×1014 Ar/cm2. A degradation of GMR with increasing Ar-ion dose is related to the formation of pinholes between Fe layers and the decrease of the antiferromagnetically coupled fraction.

  15. Epidemiologic study of Taylorella equigenitalis strains by field inversion gel electrophoresis of genomic restriction endonuclease fragments.

    PubMed Central

    Bleumink-Pluym, N; ter Laak, E A; van der Zeijst, B A

    1990-01-01

    Contagious equine metritis (CEM), a sexually transmitted bacterial disease, was first described in thoroughbred horses. It also occurs in nonthoroughbred horses, in which it produces isolated, apparently unrelated outbreaks. Thirty-two strains of Taylorella equigenitalis, the causative agent of CEM, from all over the world were characterized by field inversion gel electrophoresis of fragments of genomic DNA obtained by digestion with low-cleavage-frequency restriction enzymes. This resulted in a division into five clearly distinct groups. Strains from thoroughbred horses from all continents belonged to one group. Strains from nonthoroughbred horses from various countries were different from strains from thoroughbred horses; four groups could be determined. Two groups contained both streptomycin-resistant and streptomycin-susceptible strains. The data indicate that CEM in nonthoroughbreds did not originate from the thoroughbred population; also, the reverse was not demonstrated. Thus, extensive international transportation directives regarding the testing of nonthoroughbred horses for CEM may need reconsideration. Images PMID:2172296

  16. Influence of bicarbonate ions on the deterioration of mortar bars in sulfate solutions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kunther, W., E-mail: Wolfgang.Kunther@empa.ch; Lothenbach, B.; Scrivener, K.

    2013-02-15

    This work investigates the influence of bicarbonate ions on the deterioration of cementitious material exposed to sulfate ions. Mortars based on a CEM I and on a CEM III/B cement were investigated. Experimental investigations were compared to thermodynamic modeling and phase characterization to understand the differences in deterioration. The presence of bicarbonate ions significantly reduced the expansion of the CEM I mortars. Thermodynamic modeling showed that at high concentrations of bicarbonate ettringite and gypsum become unstable. Microstructural characterization combined with information from thermodynamic modeling suggests that conditions of high supersaturation with respect to ettringite are unlikely in the samples exposedmore » in solutions containing bicarbonate. Consequently, expansive forces are not generated by the crystallization pressure of ettringite. There was little expansion of the CEM III/B sample even in the sodium sulfate solution. In the bicarbonate solution this mortar showed a highly leached zone at the surface in which calcite was observed.« less

  17. Channel Responses and Hydromodification in Southern California

    NASA Astrophysics Data System (ADS)

    Hawley, R. J.; Dust, D. W.; Bledsoe, B. P.

    2007-12-01

    Hydromodification (changes in watershed hydrologic characteristics, and the resulting hydraulics and channel forms due to urbanization) is ubiquitous in Southern California. In this region, the effects of hydromodification are driven and compounded by the arid/semiarid climate, high relief, erodible soils, high urbanization rates, and relatively low frequency of retention/detention. We conducted a preliminary survey of over 50 stream reaches along a gradient from least disturbed to fully urbanized. All stages of the Channel Evolution Model (CEM) of Schumm et al. (1984) were observed, from stable to degrading, widening, aggrading, and quasi-equilibrium channels. Several sites have CEM stages II through V in close proximity due to headcutting, hardpoints, and infrastructure. We also observed channels in undeveloped watersheds impacted by downstream urbanization via headcutting. A range of intervention measures was observed, with the frequent evolutionary endpoint as a concrete engineered flood control channel. We also observed multiple channel evolution sequences that deviate from the CEM for single-thread, incising channels. An alternative channel response, particularly on smaller urbanized streams is a stabilized, vegetation encroached low-flow channel with regular baseflow supplied by residential irrigation runoff. The limited cases of unimpacted streams that remain tend to be high gradient, high energy systems that are naturally proximate to the transition between braided and meandering form for a given sediment size.

  18. Raman spectroscopy investigation and improved knowledge on industrial cation-exchange membranes involved in electrodialysis process

    NASA Astrophysics Data System (ADS)

    Chaouki, M.; Huguet, P.; Bribes, J.-L.

    1996-06-01

    Raman spectra of three specific, industrial, cation-exchange membranes (CEMs) have shown the existence of an extra vibrational band. The relative intensity of this band is different in each membrane spectrum recorded. Chlorosulfonation of polymeric ethylenetrifluoroethylene (ETFE) film grafted with polystyrene chains is used to obtain these CEMs involved in the electrodialysis process. A Raman study of the above reaction has been undertaken and has shown that non-sulfonated polystyrene rings give rise to this extra vibrational band. Different behavior of CEMs synthesized under similar conditions can be explained by a variable amount of non-sulfonated polystyrene rings contained in these materials.

  19. A common type system for clinical natural language processing

    PubMed Central

    2013-01-01

    Background One challenge in reusing clinical data stored in electronic medical records is that these data are heterogenous. Clinical Natural Language Processing (NLP) plays an important role in transforming information in clinical text to a standard representation that is comparable and interoperable. Information may be processed and shared when a type system specifies the allowable data structures. Therefore, we aim to define a common type system for clinical NLP that enables interoperability between structured and unstructured data generated in different clinical settings. Results We describe a common type system for clinical NLP that has an end target of deep semantics based on Clinical Element Models (CEMs), thus interoperating with structured data and accommodating diverse NLP approaches. The type system has been implemented in UIMA (Unstructured Information Management Architecture) and is fully functional in a popular open-source clinical NLP system, cTAKES (clinical Text Analysis and Knowledge Extraction System) versions 2.0 and later. Conclusions We have created a type system that targets deep semantics, thereby allowing for NLP systems to encapsulate knowledge from text and share it alongside heterogenous clinical data sources. Rather than surface semantics that are typically the end product of NLP algorithms, CEM-based semantics explicitly build in deep clinical semantics as the point of interoperability with more structured data types. PMID:23286462

  20. A common type system for clinical natural language processing.

    PubMed

    Wu, Stephen T; Kaggal, Vinod C; Dligach, Dmitriy; Masanz, James J; Chen, Pei; Becker, Lee; Chapman, Wendy W; Savova, Guergana K; Liu, Hongfang; Chute, Christopher G

    2013-01-03

    One challenge in reusing clinical data stored in electronic medical records is that these data are heterogenous. Clinical Natural Language Processing (NLP) plays an important role in transforming information in clinical text to a standard representation that is comparable and interoperable. Information may be processed and shared when a type system specifies the allowable data structures. Therefore, we aim to define a common type system for clinical NLP that enables interoperability between structured and unstructured data generated in different clinical settings. We describe a common type system for clinical NLP that has an end target of deep semantics based on Clinical Element Models (CEMs), thus interoperating with structured data and accommodating diverse NLP approaches. The type system has been implemented in UIMA (Unstructured Information Management Architecture) and is fully functional in a popular open-source clinical NLP system, cTAKES (clinical Text Analysis and Knowledge Extraction System) versions 2.0 and later. We have created a type system that targets deep semantics, thereby allowing for NLP systems to encapsulate knowledge from text and share it alongside heterogenous clinical data sources. Rather than surface semantics that are typically the end product of NLP algorithms, CEM-based semantics explicitly build in deep clinical semantics as the point of interoperability with more structured data types.

  1. Highly potent artemisinin-derived dimers and trimers: Synthesis and evaluation of their antimalarial, antileukemia and antiviral activities.

    PubMed

    Reiter, Christoph; Fröhlich, Tony; Gruber, Lisa; Hutterer, Corina; Marschall, Manfred; Voigtländer, Cornelia; Friedrich, Oliver; Kappes, Barbara; Efferth, Thomas; Tsogoeva, Svetlana B

    2015-09-01

    New pharmaceutically active compounds can be obtained by modification of existing drugs to access more effective agents in the wake of drug resistance amongst others. To achieve this goal the concept of hybridization was established during the last decade. We employed this concept by coupling two artemisinin-derived precursors to obtain dimers or trimers with increased in vitro activity against Plasmodiumfalciparum 3D7 strain, leukemia cells (CCRF-CEM and multidrug-resistant subline CEM/ADR5000) and human cytomegalovirus (HCMV). Dimer 4 (IC50 of 2.6 nM) possess superior antimalarial activity compared with its parent compound artesunic acid(3) (IC50 of 9.0 nM). Dimer5 and trimers6 and 7 display superior potency against both leukemia cell lines (IC50 up to 0.002 μM for CCRF-CEM and IC50 up to 0.20 μM for CEM/ADR5000) and are even more active than clinically used doxorubicin (IC50 1.61 μM for CEM/ADR5000). With respect to anti-HCMV activity, trimer6 is the most efficient hybrid (IC50 0.04 μM) outperforming ganciclovir (IC50 2.6 μM), dihydroartemisinin(IC50 >10 μM) and artesunic acid (IC50 3.8 μM). Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Improved performance of single-chamber microbial fuel cells through control of membrane deformation.

    PubMed

    Zhang, Xiaoyuan; Cheng, Shaoan; Huang, Xia; Logan, Bruce E

    2010-03-15

    Cation (CEMs) and anion exchange membrane (AEMs) are commonly used in microbial fuel cells (MFCs) to enhance Coulombic efficiencies (CEs) by reducing the flux of oxygen through the cathode to bacteria on the anode. AEMs typically work better than CEMs, but in initial experiments we observed the opposite using a membrane electrode assembly MFC. The reason was identified to be membrane deformation, which resulted in water and gas trapped between the membrane and cathode. To correct this, stainless steel mesh was used to press the membrane flat against the cathode. With the steel mesh, AEM performance increased to 46+/-4 W/m(3) in a single cathode MFC, and 98+/-14 W/m(3) in a double-cathode MFC. These power densities were higher than those using a CEM of 32+/-2 W/m(3) (single cathode) and 63+/-6 W/m(3) (double cathode). Higher pH gradients across the membrane and salt precipitation on the cathode were responsible for the reduced performance of the CEM compared to the AEM. CEs reached over 90% for both membranes at >2A/m(2). These results demonstrate the importance of avoiding water accumulation in thin films between membranes and electrodes, and explain additional reasons for poorer performance of CEMs compared to AEMs. (c) 2009 Elsevier B.V. All rights reserved.

  3. An 'Early Warning System' for the prevention of dredging potential impacts on sensitive areas

    NASA Astrophysics Data System (ADS)

    Piermattei, Viviana; Martellucci, Riccardo; Pierattini, Alberto; Bonamano, Simone; Paladini de Mendoza, Francesco; Albani, Marta; Stefanì, Chiara; Madonia, Alice; Fersini, Giorgio; Marcelli, Marco

    2016-04-01

    Coastal marine ecosystems are increasingly subject to multiple pressures and stressors produced by the effects of human activities. Intense and frequent disturbances which affect marine environment can derive from dredging activity, which is a fundamental management for most ports and harbours. The potential environmental effects of dredging procedures are generally due to the excavation of material from the sea bottom and the relocation elsewhere for disposal, overflow from the dredger and loss of material from pipelines during transport. Depending on the location and the intensity of these activities the marine environment, particularly sensitive areas, may be affected by dredging. The main environmental effects can be associated with suspended sediments and increases in turbidity into the water column, which can have adverse effects on marine animals and plants by reducing light penetration and by physical disturbance. For this reason it is fundamental to implement a real time monitoring system to control and prevent negative effects, enabling a rapid response to adverse water quality conditions and a fast activation of mitigation procedures, in agreement with all the reference authorities. In this work we present the development of an innovative 'Early Warning System' based on fixed stations, ad hoc in situ surveys and forecasting models, which was applied to a dredging activity carried out in the Gulf of Gaeta (Latium, Italy). It represents an extension of the C-CEMS (Civitavecchia Coastal Environmental Monitoring System) network, which is operative in the Tyrrhenian sea since 2005.

  4. A crush zone design for an existing passenger rail cab car

    DOT National Transportation Integrated Search

    2005-11-05

    A Crash Energy Management (CEM) cab car crush zone : design has been developed for retrofit onto an existing Budd : M1 cab car. This design is to be used in the upcoming fullscale : train-to-train test of a CEM consist impacting a standing : freight ...

  5. The influence of train type, car weight, and train length on passenger train crashworthiness

    DOT National Transportation Integrated Search

    2005-03-16

    Crash energy management (CEM) is a type of equipment : design that is intended to protect occupant space during a : collision. Structures at the front and back of each car act as : crumple zones that absorb the collision energy. CEM is : intended to ...

  6. Fast and selective cell isolation from blood sample by microfiber fabric system with vacuum aspiration

    NASA Astrophysics Data System (ADS)

    Ueki, Takayuki; Yoshihara, Akifumi; Teramura, Yuji; Takai, Madoka

    2016-01-01

    Since circulating tumor cells (CTCs) are tumor cells which are found in the blood of cancer patients, CTCs are potential tumor markers, so a rapid isolation of CTCs is desirable for clinical applications. In this paper, a three-dimensional polystyrene (PS) microfiber fabric with vacuum aspiration system was developed for capturing CTCs within a short time. Various microfiber fabrics with different diameters were prepared by the electrospinning method and optimized for contact frequency with cells. Vacuum aspiration utilizing these microfiber fabrics could filter all cells within seconds without mechanical damage. The microfiber fabric with immobilized anti-EpCAM antibodies was able to specifically capture MCF-7 cells that express EpCAM on their surfaces. The specificity of the system was confirmed by monitoring the ability to isolate MCF-7 cells from a mixture containing CCRF-CEM cells that do not express EpCAM. Furthermore, the selective capture ability of the microfiber was retained even when the microfiber was exposed to the whole blood of pigs spiked with MCF-7 cells. The specific cell capture ratio of the vacuum aspiration system utilizing microfiber fabric could be improved by increasing the thickness of the microfiber fabric through electrospinning time.

  7. Mechanical and physical properties of cement blended with sewage sludge ash.

    PubMed

    Garcés, P; Pérez Carrión, M; García-Alcocel, E; Payá, J; Monzó, J; Borrachero, M V

    2008-12-01

    The aim of this paper is to evaluate the compatibility of sewage sludge ash (SSA) with various types of commercially available cements (CEM I and CEM II types, cements with several proportions of clinker). The behaviour of mortars fabricated with various percentages (10-30% by weight) of the cement replaced by SSA has been analyzed in terms of workability, mechanical strength, porosity and shrinkage/expansion. SSA exhibits moderate pozzolanic activity; the highest compressive strengths were obtained with 10% of the cement replaced by SSA. The CEM II/B-M (V-LL) 42.5R cement is considered ideal for preparing mortars containing SSA. Shrinkage data demonstrate that sulphates present in SSA are not reactive towards cement.

  8. 40 CFR 63.1349 - Performance testing requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... in accordance with § 63.1346(c)(1). (4) THC emissions test. (i) If you are subject to limitations on THC emissions, you must operate a CEMS in accordance with the requirements in § 63.1350(i). For the purposes of conducting the accuracy and quality assurance evaluations for CEMS, the THC span value (as...

  9. 40 CFR 63.1349 - Performance testing requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...)(1). (4)(i) THC CEMS relative accuracy test. (A) If you are subject to limitations on THC emissions... CEMS, the THC span value (as propane) is 50 ppmvd. You demonstrate compliance with a RATA when the... conducting the performance test for total organic HAP, you must also determine THC emissions by operating a...

  10. 40 CFR 63.1349 - Performance testing requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...)(1). (4)(i) THC CEMS relative accuracy test. (A) If you are subject to limitations on THC emissions... CEMS, the THC span value (as propane) is 50 ppmvd. You demonstrate compliance with a RATA when the... conducting the performance test for total organic HAP, you must also determine THC emissions by operating a...

  11. Performance characteristics of high-conductivity channel electron multipliers. [as UV and x ray detector

    NASA Technical Reports Server (NTRS)

    Timothy, J. G.; Bybee, R. L.

    1978-01-01

    The paper describes a new type of continuous channel multiplier (CEM) fabricated from a low-resistance glass to produce a high-conductivity channel section and thereby obtain a high count-rate capability. The flat-cone cathode configuration of the CEM is specifically designed for the detection of astigmatic exit images from grazing-incidence spectrometers at the optimum angle of illumination for high detection efficiencies at XUV wavelengths. Typical operating voltages are in the range of 2500-2900 V with stable counting plateau slopes in the range 3-6% per 100-V increment. The modal gain at 2800 V was typically in the range (50-80) million. The modal gain falls off at count rates in excess of about 20,000 per sec. The detection efficiency remains essentially constant to count rates in excess of 2 million per sec. Higher detection efficiencies (better than 20%) are obtained by coating the CEM with MgF2. In life tests of coated CEMs, no measurable change in detection efficiency was measured to a total accumulated signal of 2 times 10 to the 11th power counts.

  12. Crystalline phases involved in the hydration of calcium silicate-based cements: Semi-quantitative Rietveld X-ray diffraction analysis.

    PubMed

    Grazziotin-Soares, Renata; Nekoofar, Mohammad H; Davies, Thomas; Hübler, Roberto; Meraji, Naghmeh; Dummer, Paul M H

    2017-08-30

    Chemical comparisons of powder and hydrated forms of calcium silicate cements (CSCs) and calculation of alterations in tricalcium silicate (Ca 3 SiO 5 ) calcium hydroxide (Ca(OH) 2 ) are essential for understanding their hydration processes. This study aimed to evaluate and compare these changes in ProRoot MTA, Biodentine and CEM cement. Powder and hydrated forms of tooth coloured ProRoot MTA, Biodentine and CEM cement were subjected to X-ray diffraction (XRD) analysis with Rietveld refinement to semi-quantitatively identify and quantify the main phases involved in their hydration process. Data were reported descriptively. Reduction in Ca 3 SiO 5 and formation of Ca(OH) 2 were seen after the hydration of ProRoot MTA and Biodentine; however, in the case of CEM cement, no reduction of Ca 3 SiO 5 and no formation of Ca(OH) 2 were detected. The highest percentages of amorphous phases were seen in Biodentine samples. Ettringite was detected in the hydrated forms of ProRoot MTA and CEM cement but not in Biodentine. © 2017 Australian Society of Endodontology Inc.

  13. Current perspectives of bio-ceramic technology in endodontics: calcium enriched mixture cement - review of its composition, properties and applications

    PubMed Central

    Nawal, Ruchika Roongta; Talwar, Sangeeta; Verma, Mahesh

    2015-01-01

    Advancements in bio-ceramic technology has revolutionised endodontic material science by enhancing the treatment outcome for patients. This class of dental materials conciliates excellent biocompatibility with high osseoconductivity that render them ideal for endodontic care. Few recently introduced bio-ceramic materials have shown considerable clinical success over their early generations in terms of good handling characteristics. Calcium enriched mixture (CEM) cement, Endosequence sealer, and root repair materials, Biodentine and BioAggregate are the new classes of bio-ceramic materials. The aim of this literature review is to present investigations regarding properties and applications of CEM cement in endodontics. A review of the existing literature was performed by using electronic and hand searching methods for CEM cement from January 2006 to December 2013. CEM cement has a different chemical composition from that of mineral trioxide aggregate (MTA) but has similar clinical applications. It combines the biocompatibility of MTA with more efficient characteristics, such as significantly shorter setting time, good handling characteristics, no staining of tooth and effective seal against bacterial leakage. PMID:25671207

  14. Comparing the short and long term stability of biodegradable, ceramic and cation exchange membranes in microbial fuel cells.

    PubMed

    Winfield, Jonathan; Chambers, Lily D; Rossiter, Jonathan; Ieropoulos, Ioannis

    2013-11-01

    The long and short-term stability of two porous dependent ion exchange materials; starch-based compostable bags (BioBag) and ceramic, were compared to commercially available cation exchange membrane (CEM) in microbial fuel cells. Using bi-directional polarisation methods, CEM exhibited power overshoot during the forward sweep followed by significant power decline over the reverse sweep (38%). The porous membranes displayed no power overshoot with comparably smaller drops in power during the reverse sweep (ceramic 8%, BioBag 5.5%). The total internal resistance at maximum power increased by 64% for CEM compared to 4% (ceramic) and 6% (BioBag). Under fixed external resistive loads, CEM exhibited steeper pH reductions than the porous membranes. Despite its limited lifetime, the BioBag proved an efficient material for a stable microbial environment until failing after 8 months, due to natural degradation. These findings highlight porous separators as ideal candidates for advancing MFC technology in terms of cost and operation stability. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. BMDO Technology and the Electric Utility Industry

    DTIC Science & Technology

    1997-01-01

    use flue gas desulfurization systems, called scrubbers, to control the emissions of S02. In general, such systems allow combustion gases to pass...M) of flue gas desulfurization systems were about .0114 cents per kilowatt-hour. This small fraction of a penny translates to hundreds of millions...diluent gas , and opacity of units (the percentage of light that one can see through the flue gas ). According to requirements, CEM equipment must be

  16. Production of energetic light fragments in extensions of the CEM and LAQGSM event generators of the Monte Carlo transport code MCNP6 [Production of energetic light fragments in CEM, LAQGSM, and MCNP6

    DOE PAGES

    Mashnik, Stepan Georgievich; Kerby, Leslie Marie; Gudima, Konstantin K.; ...

    2017-03-23

    We extend the cascade-exciton model (CEM), and the Los Alamos version of the quark-gluon string model (LAQGSM), event generators of the Monte Carlo N-particle transport code version 6 (MCNP6), to describe production of energetic light fragments (LF) heavier than 4He from various nuclear reactions induced by particles and nuclei at energies up to about 1 TeV/nucleon. In these models, energetic LF can be produced via Fermi breakup, preequilibrium emission, and coalescence of cascade particles. Initially, we study several variations of the Fermi breakup model and choose the best option for these models. Then, we extend the modified exciton model (MEM)more » used by these codes to account for a possibility of multiple emission of up to 66 types of particles and LF (up to 28Mg) at the preequilibrium stage of reactions. Then, we expand the coalescence model to allow coalescence of LF from nucleons emitted at the intranuclear cascade stage of reactions and from lighter clusters, up to fragments with mass numbers A ≤ 7, in the case of CEM, and A ≤ 12, in the case of LAQGSM. Next, we modify MCNP6 to allow calculating and outputting spectra of LF and heavier products with arbitrary mass and charge numbers. The improved version of CEM is implemented into MCNP6. Lastly, we test the improved versions of CEM, LAQGSM, and MCNP6 on a variety of measured nuclear reactions. The modified codes give an improved description of energetic LF from particle- and nucleus-induced reactions; showing a good agreement with a variety of available experimental data. They have an improved predictive power compared to the previous versions and can be used as reliable tools in simulating applications involving such types of reactions.« less

  17. Production of energetic light fragments in extensions of the CEM and LAQGSM event generators of the Monte Carlo transport code MCNP6 [Production of energetic light fragments in CEM, LAQGSM, and MCNP6

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mashnik, Stepan Georgievich; Kerby, Leslie Marie; Gudima, Konstantin K.

    We extend the cascade-exciton model (CEM), and the Los Alamos version of the quark-gluon string model (LAQGSM), event generators of the Monte Carlo N-particle transport code version 6 (MCNP6), to describe production of energetic light fragments (LF) heavier than 4He from various nuclear reactions induced by particles and nuclei at energies up to about 1 TeV/nucleon. In these models, energetic LF can be produced via Fermi breakup, preequilibrium emission, and coalescence of cascade particles. Initially, we study several variations of the Fermi breakup model and choose the best option for these models. Then, we extend the modified exciton model (MEM)more » used by these codes to account for a possibility of multiple emission of up to 66 types of particles and LF (up to 28Mg) at the preequilibrium stage of reactions. Then, we expand the coalescence model to allow coalescence of LF from nucleons emitted at the intranuclear cascade stage of reactions and from lighter clusters, up to fragments with mass numbers A ≤ 7, in the case of CEM, and A ≤ 12, in the case of LAQGSM. Next, we modify MCNP6 to allow calculating and outputting spectra of LF and heavier products with arbitrary mass and charge numbers. The improved version of CEM is implemented into MCNP6. Lastly, we test the improved versions of CEM, LAQGSM, and MCNP6 on a variety of measured nuclear reactions. The modified codes give an improved description of energetic LF from particle- and nucleus-induced reactions; showing a good agreement with a variety of available experimental data. They have an improved predictive power compared to the previous versions and can be used as reliable tools in simulating applications involving such types of reactions.« less

  18. Reliability of plasma polar metabolite concentrations in a large-scale cohort study using capillary electrophoresis-mass spectrometry.

    PubMed

    Harada, Sei; Hirayama, Akiyoshi; Chan, Queenie; Kurihara, Ayako; Fukai, Kota; Iida, Miho; Kato, Suzuka; Sugiyama, Daisuke; Kuwabara, Kazuyo; Takeuchi, Ayano; Akiyama, Miki; Okamura, Tomonori; Ebbels, Timothy M D; Elliott, Paul; Tomita, Masaru; Sato, Asako; Suzuki, Chizuru; Sugimoto, Masahiro; Soga, Tomoyoshi; Takebayashi, Toru

    2018-01-01

    Cohort studies with metabolomics data are becoming more widespread, however, large-scale studies involving 10,000s of participants are still limited, especially in Asian populations. Therefore, we started the Tsuruoka Metabolomics Cohort Study enrolling 11,002 community-dwelling adults in Japan, and using capillary electrophoresis-mass spectrometry (CE-MS) and liquid chromatography-mass spectrometry. The CE-MS method is highly amenable to absolute quantification of polar metabolites, however, its reliability for large-scale measurement is unclear. The aim of this study is to examine reproducibility and validity of large-scale CE-MS measurements. In addition, the study presents absolute concentrations of polar metabolites in human plasma, which can be used in future as reference ranges in a Japanese population. Metabolomic profiling of 8,413 fasting plasma samples were completed using CE-MS, and 94 polar metabolites were structurally identified and quantified. Quality control (QC) samples were injected every ten samples and assessed throughout the analysis. Inter- and intra-batch coefficients of variation of QC and participant samples, and technical intraclass correlation coefficients were estimated. Passing-Bablok regression of plasma concentrations by CE-MS on serum concentrations by standard clinical chemistry assays was conducted for creatinine and uric acid. In QC samples, coefficient of variation was less than 20% for 64 metabolites, and less than 30% for 80 metabolites out of the 94 metabolites. Inter-batch coefficient of variation was less than 20% for 81 metabolites. Estimated technical intraclass correlation coefficient was above 0.75 for 67 metabolites. The slope of Passing-Bablok regression was estimated as 0.97 (95% confidence interval: 0.95, 0.98) for creatinine and 0.95 (0.92, 0.96) for uric acid. Compared to published data from other large cohort measurement platforms, reproducibility of metabolites common to the platforms was similar to or better than in the other studies. These results show that our CE-MS platform is suitable for conducting large-scale epidemiological studies.

  19. Modulation of transferrin receptor mRNA by transferrin-gallium in human myeloid HL60 and lymphoid CCRF-CEM leukaemic cells.

    PubMed Central

    Ul-Haq, R; Chitambar, C R

    1993-01-01

    Gallium binds to the iron transport protein transferrin (Tf), is incorporated into cells through transferrin receptors (TfR) and inhibits iron-dependent DNA synthesis. Since cellular TfR expression is tightly regulated by the availability of iron, we investigated the effects of transferrin-gallium (Tf-Ga) on TfR mRNA levels in myeloid HL60 and lymphoid CCRF-CEM cells. In HL60 cells, Tf-Ga increased TfR mRNA levels in a dose-dependent fashion. This increase in TfR mRNA was blocked by Tf-Fe and by cycloheximide. Analysis of the rate of mRNA decay in the presence of actinomycin D revealed that the half-life of TfR mRNA was increased in HL60 cells incubated with Tf-Ga. The rate of transcription of TfR mRNA was not increased by Tf-Ga. In contrast with HL60 cells, CCRF-CEM cells displayed a decrease in the level of TfR mRNA after incubation with Tf-Ga. Tf-Ga inhibited iron uptake in both HL60 and CCRF-CEM cells but increased the level of TfR mRNA only in HL60 cells, suggesting that the Tf-Ga induction of TfR mRNA was not solely due to inhibition of cellular iron uptake. At growth-inhibitory concentrations, Tf-Ga increased the TfR mRNA level in HL60 cells but decreased it in CCRF-CEM cells. Our studies suggest that in HL60 cells, gallium regulates TfR expression at the post-transcriptional level by mechanisms which require de novo protein synthesis and involve interaction with iron. The divergent effects of Tf-Ga on TfR mRNA in myeloid HL60 and lymphoid CCRF-CEM cells suggest that differences exist in the regulation of TfR expression between these two cell types. Images Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 PMID:8379943

  20. Relationships between thermal dose parameters and the efficacy of definitive chemoradiotherapy plus regional hyperthermia in the treatment of locally advanced cervical cancer: data from a multicentre randomised clinical trial.

    PubMed

    Ohguri, Takayuki; Harima, Yoko; Imada, Hajime; Sakurai, Hideyuki; Ohno, Tatsuya; Hiraki, Yoshiyuki; Tuji, Koh; Tanaka, Masahiro; Terashima, Hiromi

    2018-06-01

    To evaluate the contribution of the thermal dose parameters during regional hyperthermia (HT) treatment to the clinical outcomes in patients with cervical carcinoma (CC) who received chemoradiotherapy (CRT) plus HT. Data from a multicentre randomised clinical trial of concurrent CRT + HT vs. CRT alone were used to evaluate the efficacy and safety of this combination therapy in the CC patients. The intrarectal temperatures of patients undergoing HT were recorded. The complete thermal data of 47 (92%) of the 51 patients in the CRT + HT group were available for the thermal analysis. Thus, 47 patients who received CRT + HT were included in the present study. Among the patients who received CRT + HT, a higher CEM43T90 (≥1 min) value (a thermal dose parameter) was significantly associated with better local relapse-free survival in both univariate (p = 0.024) and multivariate (p = 0.0097) analyses. The disease-free survival of the patients with higher CEM43T90 (≥1 min) values tended to be better in comparison to patients with lower CEM43T90 (<1 min) value (p = 0.071). A complete response tended to be associated with the CEM43T90 (p = 0.056). Disease-free survival, local relapse-free survival and complete response rate for patients with higher CEM43T90 (≥1) were significantly better than those for patients with CRT alone (p = 0.036, p = 0.036 and p = 0.048). Dose-effect relationships between thermal dose parameters and clinical outcomes were confirmed in the CC patients treated with a combination of CRT + HT. This study also confirmed that HT with lower CEM43T90 is insufficient to achieve a significant hyperthermic sensitisation to CRT.

  1. Effect of Cements at Different Temperatures on the Clinical Performance and Marginal Adaptation of Inlay-Onlay Restorations In Vivo.

    PubMed

    Aygün Emiroğlu, Şeyda; Evren, Buket; Kulak Özkan, Yasemin

    2016-06-01

    To evaluate the clinical performance of inlays and onlays luted with two different resin cements, mixed at different temperatures and to evaluate the marginal adaptation of the restorations. One hundred IPS e.max restorations (82 onlays, 18 inlays; 84 molars, 16 premolars) were placed in 50 patients (28 females, 22 males, mean age, 33 years). The restorations were assigned to six groups according to the luting agent temperature (25°C, 37°C, and 54°C) and cement type (Variolink N high viscosity or G-Cem Automix). All restorations were evaluated after 1 week and 1 year by two examiners using modified USPHS criteria. Replicas of 30 selected onlay restorations (5 per group) were assessed for marginal quality under a scanning electron microscope (SEM) at 200×. Marginal adaptation was quantitatively evaluated in terms of percentage of gap formation, and marginal gap width was measured. After 1 year, the total survival rates of the Variolink N high viscosity group and G-Cem Automix group were 100% and 93.8%, respectively. Three debondings occurred with the G-Cem Automix group, one from each temperature group. For 1-year clinical service time, no significant difference was noticed in the marginal adaptation of Variolink N high viscosity groups and the 37°C G-Cem Automix group, while 25°C and 54°C G-Cem Automix groups' marginal adaptation scores decreased (p < 0.05). Regarding the SEM evaluations, Variolink N high viscosity cement groups showed better marginal adaptation than G-Cem Automix cement groups (p < 0.05). Cementation with the cements preheated to 37°C increased continuous margins in both enamel-cement and cement-ceramic interfaces, but these results were not statistically significant (p > 0.05). Cements at different temperatures did not have significant effects on marginal gap widths of the restorations. The restorations cemented with Variolink N high viscosity cement mixed at the three tested temperatures exhibited better treatment options than the self-adhesive groups. Preheating the self-adhesive cement (G-Cem Automix) to 37°C can be an effective method to have better marginal adaptation than the other self-adhesive groups (25°C, 54°C) tested in this study. © 2015 by the American College of Prosthodontists.

  2. Flight Model Discharge System

    DTIC Science & Technology

    1989-09-01

    Itterconnection wiring diagram for the ESA ............................... 34 3-13 Typical gain versus total count curve for CEM...42 3-16 Calibration curve for energy bin 12 of the ion ESA ....................... 43 3-17 Flight ESA S/N001...Calibration curves for SPM S/N001 ......................................... 67 4-11 Calibration curves for SPM S/N002

  3. Electrodialytic 2-compartment cells for emerging organic contaminants removal from effluent.

    PubMed

    Ferreira, Ana Rita; Couto, Nazaré; Guedes, Paula; Pinto, Joana; Mateus, Eduardo P; Ribeiro, Alexandra B

    2018-04-27

    The present work discusses the efficiency of the electrodialytic (ED) process to remove emerging organic contaminants (EOCs) from effluent. The ED process was carried out in a cell of two-compartments (2 C-cell) with effluent in either the anode or cathode compartment, separated from the electrolyte compartment through an anion or a cation exchange membrane (AEM and CEM, respectively). As effluent destination might be soil irrigation, and having in mind the nutrient recycling, phosphorus was also monitored in the process. The ED removals showed to be dependent of EOCs characteristics and cell design. Removals were higher when using an AEM (60-72%) than a CEM (8-63%), except for caffeine when the effluent was placed in the cathode, that did not show any removal. When using an AEM with the effluent placed in the anode compartment, all the EOCs (including caffeine) were removed between 57-72%, mainly through electrodegradation phenomena. Regarding phosphorus, a polarity switch may be done to a 2 C-cell with a AEM, depending on the effluent final use. This technology is still in its first steps and, in both cases, further optimization of ED parameters is needed. Still, this technological innovation and cross-cutting research envisages the promotion of economic, social and environmental benefits. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Pressurized liquid extraction combined with capillary electrophoresis-mass spectrometry as an improved methodology for the determination of sulfonamide residues in meat.

    PubMed

    Font, Guillermina; Juan-García, Ana; Picó, Yolanda

    2007-08-03

    A new analytical method, based on capillary electrophoresis and tandem mass spectrometry (CE-MS2), is proposed and validated for the identification and simultaneous quantification of 12 sulfonamides (SAs) in pork meat. The studied SAs include sulfathiazole, sulfadiazine, sulfamethoxypyridazine, sulfaguanidine, sulfanilamide, sulfadimethoxyne, sulfapyridine, sulfachloropyridazine, sulfisoxazole, sulfasalazine, sulfabenzamide and sulfadimidine. Different parameters (i.e. separation buffer, sheath liquid, electrospray conditions) were optimized to obtain an adequate CE separation and high MS sensitivity. MS2 experiments using an ion trap as analyzer, operating in the selected reaction monitoring (SRM) mode, were carried out to achieve the required number of identification points according to the 2002/657/EC European Decision. For the quantification in pork tissue samples, a pressurized liquid extraction (PLE) procedure, using hot water as extractant followed by an Oasis HLB cleanup, was developed. Linearity (r between 0.996 and 0.997), precision (RSD<14 %) and recoveries (from 76 to 98%) were satisfactory. The limits of detection and quantification (below 12.5 and 46.5 microg kg(-1), respectively) were in all cases lower than the maximum residue limits (MRLs), indicating the potential of CE-MS2 for the analysis of SAs, in the food quality and safety control areas.

  5. Isolation and characterization of dexamethasone-resistant mutants from human lymphoid cell line CEM-C7

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harmon, J.M.; Thompson, E.B.

    1981-06-01

    Fifty-four independent dexamethasone-resistant clones were isolated from the clonal, glucocorticoid-sensitive human leukemic T-cell line CEM-C7. Resistance to 1 ..mu..M dexamethasone was acquired spontaneously at a rate of 2.6 x 10/sup -5/ per cell per generation as determined by fluctuation analysis. After mutagenesis with N-methyl-N'-nitro-N-nitrosoguanidine (MNNG), the phenotypic expression time for dexamethasone resistance was determined to be 3 days. The mutagens ICR 191 and MNNG were effective in increasing the dexamethasone-resistant fraction of cells in mutagenized cultures; ICR 191 produced a 35.6-fold increase, and MNNG produced an 8.5-fold increase. All the spontaneous dexamethasone-resistant clones contained glucocorticoid receptors, usually less than halfmore » of the amount found in the parental clone. They are therefore strikingly different from dexamethasone-resistant clones derived from the mouse cell lines S49 and W7. Dexamethasone-resistant clones isolated after mutagenesis of CEM-C7 contained, on the average, lower concentrations of receptor than did those isolated spontaneously, and one clone contained no detectable receptor. These results are consistent with a mutational origin for dexamethasone resistance in these human cells at a haploid or functionally hemizygous locus. They also suggest that this is a useful system for mutation assay.« less

  6. Effect of different fermentation strategies on β-mannanase production in fed-batch bioreactor system.

    PubMed

    Germec, Mustafa; Yatmaz, Ercan; Karahalil, Ercan; Turhan, İrfan

    2017-05-01

    Mannanases, one of the important enzyme group for industry, are produced by numerous filamentous fungi, especially Aspergillus species with different fermentation methods. The aim of this study was to show the best fermentation method of β-mannanase production for fungal growth in fermenter. Therefore, different fermentation strategies in fed-batch fermentation (suspended, immobilized cell, biofilm and microparticle-enhanced bioreactor) were applied for β-mannanase production from glucose medium (GM) and carob extract medium (CEM) by using recombinant Aspergillus sojae. The highest β-mannanase activities were obtained from microparticle-enhanced bioreactor strategy. It was found to be 347.47 U/mL by adding 10 g/L of Al 2 O 3 to GM and 439.13 U/mL by adding 1 g/L of talcum into CEM. The maximum β-mannanase activities for suspended, immobilization, and biofilm reactor remained at 72.55 U/mL in GM, 148.81 U/mL in CEM, and 194.09 U/mL in GM, respectively. The reason for that is the excessive, and irregular shaped growth and bulk formation, inadequate oxygen transfer or substrate diffusion in bioreactor. Consequently, the enzyme activity was significantly enhanced by addition of microparticles compared to other fed-batch fermentation strategies. Also, repeatable β-mannanase activities were obtained by controlling of the cell morphology by adding microparticle inside the fermenter.

  7. 2,6-Dithiopurine blocks toxicity and mutagenesis in human skin cells exposed to sulfur mustard analogues, 2-chloroethyl ethyl sulfide and 2-chloroethyl methyl sulfide.

    PubMed

    Powell, K Leslie; Boulware, Stephen; Thames, Howard; Vasquez, Karen M; MacLeod, Michael C

    2010-03-15

    Sulfur mustard (bis-(2-chloroethyl)sulfide) is a well-known chemical warfare agent that induces debilitating cutaneous toxicity in exposed individuals. It is also known to be carcinogenic and mutagenic because of its ability to damage DNA via electrophilic attack. We previously showed that a nucleophilic scavenger, 2,6-dithiopurine (DTP), reacts chemically with several electrophilic carcinogens, blocking DNA damage in vitro and in vivo and abolishing tumor formation in a two-stage mouse skin carcinogenesis model. To assess the potential of DTP as an antagonist of sulfur mustard, we have utilized monofunctional chemical analogues of sulfur mustard, 2-chloroethyl ethyl sulfide (CEES) and 2-chloroethyl methyl sulfide (CEMS), to induce toxicity and mutagenesis in a cell line, NCTC2544, derived from a human skin tumor. We show that DTP blocks cytotoxicity in CEMS- and CEES-treated cells when present at approximately equimolar concentration. A related thiopurine, 9-methyl-6-mercaptopurine, is similarly effective. Correlated with this, we find that DTP is transported into these cells and that adducts between DTP and CEES are found intracellularly. Using a shuttle vector-based mutagenesis system, which allows enumeration of mutations induced in the skin cells by a blue/white colony screen, we find that DTP completely abolishes the mutagenesis induced by CEMS and CEES in human cells.

  8. Proteomics as a Quality Control Tool of Pharmaceutical Probiotic Bacterial Lysate Products

    PubMed Central

    Klein, Günter; Schanstra, Joost P.; Hoffmann, Janosch; Mischak, Harald; Siwy, Justyna; Zimmermann, Kurt

    2013-01-01

    Probiotic bacteria have a wide range of applications in veterinary and human therapeutics. Inactivated probiotics are complex samples and quality control (QC) should measure as many molecular features as possible. Capillary electrophoresis coupled to mass spectrometry (CE/MS) has been used as a multidimensional and high throughput method for the identification and validation of biomarkers of disease in complex biological samples such as biofluids. In this study we evaluate the suitability of CE/MS to measure the consistency of different lots of the probiotic formulation Pro-Symbioflor which is a bacterial lysate of heat-inactivated Escherichia coli and Enterococcus faecalis. Over 5000 peptides were detected by CE/MS in 5 different lots of the bacterial lysate and in a sample of culture medium. 71 to 75% of the total peptide content was identical in all lots. This percentage increased to 87–89% when allowing the absence of a peptide in one of the 5 samples. These results, based on over 2000 peptides, suggest high similarity of the 5 different lots. Sequence analysis identified peptides of both E. coli and E. faecalis and peptides originating from the culture medium, thus confirming the presence of the strains in the formulation. Ontology analysis suggested that the majority of the peptides identified for E. coli originated from the cell membrane or the fimbrium, while peptides identified for E. faecalis were enriched for peptides originating from the cytoplasm. The bacterial lysate peptides as a whole are recognised as highly conserved molecular patterns by the innate immune system as microbe associated molecular pattern (MAMP). Sequence analysis also identified the presence of soybean, yeast and casein protein fragments that are part of the formulation of the culture medium. In conclusion CE/MS seems an appropriate QC tool to analyze complex biological products such as inactivated probiotic formulations and allows determining the similarity between lots. PMID:23840518

  9. Profiling Fast Healthcare Interoperability Resources (FHIR) of Family Health History based on the Clinical Element Models.

    PubMed

    Lee, Jaehoon; Hulse, Nathan C; Wood, Grant M; Oniki, Thomas A; Huff, Stanley M

    2016-01-01

    In this study we developed a Fast Healthcare Interoperability Resources (FHIR) profile to support exchanging a full pedigree based family health history (FHH) information across multiple systems and applications used by clinicians, patients, and researchers. We used previously developed clinical element models (CEMs) that are capable of representing the FHH information, and derived essential data elements including attributes, constraints, and value sets. We analyzed gaps between the FHH CEM elements and existing FHIR resources. Based on the analysis, we developed a profile that consists of 1) FHIR resources for essential FHH data elements, 2) extensions for additional elements that were not covered by the resources, and 3) a structured definition to integrate patient and family member information in a FHIR message. We implemented the profile using an open-source based FHIR framework and validated it using patient-entered FHH data that was captured through a locally developed FHH tool.

  10. Exploring Robust Methods for Evaluating Treatment and Comparison Groups in Chronic Care Management Programs

    PubMed Central

    Hamar, Brent; Bradley, Chastity; Gandy, William M.; Harrison, Patricia L.; Sidney, James A.; Coberley, Carter R.; Rula, Elizabeth Y.; Pope, James E.

    2013-01-01

    Abstract Evaluation of chronic care management (CCM) programs is necessary to determine the behavioral, clinical, and financial value of the programs. Financial outcomes of members who are exposed to interventions (treatment group) typically are compared to those not exposed (comparison group) in a quasi-experimental study design. However, because member assignment is not randomized, outcomes reported from these designs may be biased or inefficient if study groups are not comparable or balanced prior to analysis. Two matching techniques used to achieve balanced groups are Propensity Score Matching (PSM) and Coarsened Exact Matching (CEM). Unlike PSM, CEM has been shown to yield estimates of causal (program) effects that are lowest in variance and bias for any given sample size. The objective of this case study was to provide a comprehensive comparison of these 2 matching methods within an evaluation of a CCM program administered to a large health plan during a 2-year time period. Descriptive and statistical methods were used to assess the level of balance between comparison and treatment members pre matching. Compared with PSM, CEM retained more members, achieved better balance between matched members, and resulted in a statistically insignificant Wald test statistic for group aggregation. In terms of program performance, the results showed an overall higher medical cost savings among treatment members matched using CEM compared with those matched using PSM (-$25.57 versus -$19.78, respectively). Collectively, the results suggest CEM is a viable alternative, if not the most appropriate matching method, to apply when evaluating CCM program performance. (Population Health Management 2013;16:35–45) PMID:22788834

  11. Erythrocyte membrane cholesterol and lipid core growth in a rabbit model of atherosclerosis: modulatory effects of rosuvastatin.

    PubMed

    Tziakas, Dimitrios; Chalikias, Georgios; Kapelouzou, Alkistis; Tentes, Ioannis; Schäfer, Katrin; Karayannakos, Panagiotis; Kostakis, Alkiviadis; Boudoulas, Harissios; Konstantinides, Stavros

    2013-12-10

    Lipid core expansion is partly responsible for the conversion of a stable atherosclerotic lesion to a rupture-prone plaque. Intraplaque hemorrhage contributes to the accumulation of cholesterol within unstable plaques. In the present study, we investigated, using a rabbit model of atherosclerosis, the extent to which diet-induced increases in cholesterol content of erythrocyte membranes (CEM) contribute to lipid core expansion and the modulatory effect of rosuvastatin use. Rabbits fed with atherogenic diet (0.75% cholesterol) for 5 months exhibited advanced atherosclerotic lesions (mean plaque area, 0.39 ± 0.03 mm(2)), and lipid core size was associated with the concentration-time integral (CTI) of CEM levels (r=0.567, P=0.004) independent of other established predictors of lipid core size. Further experiments were performed by feeding rabbits atherogenic diet (1% cholesterol) for 3 months, followed by either normal diet or normal diet plus rosuvastatin for the next 3 months. Although no differences were observed in total plaque area between both groups, administration of rosuvastatin was associated with significantly smaller lipid cores, fewer macrophages within the lipid core, less microvessels as well as with lower CTI of CEM levels compared to normal diet alone. Moreover, intraplaque erythrocyte membranes covered a smaller lipid core area in rabbits under rosuvastatin plus normal diet as opposed to rabbits under diet alone. Increased CEM levels, induced by high-cholesterol diet, are associated with lipid core growth. Ingestion of a potent HMG-CoA reductase inhibitor (rosuvastatin) may decrease CEM levels, and this effect may contribute to regression of the lipid core. © 2013.

  12. Integrated active and passive control design methodology for the LaRC CSI evolutionary model

    NASA Technical Reports Server (NTRS)

    Voth, Christopher T.; Richards, Kenneth E., Jr.; Schmitz, Eric; Gehling, Russel N.; Morgenthaler, Daniel R.

    1994-01-01

    A general design methodology to integrate active control with passive damping was demonstrated on the NASA LaRC CSI Evolutionary Model (CEM), a ground testbed for future large, flexible spacecraft. Vibration suppression controllers designed for Line-of Sight (LOS) minimization were successfully implemented on the CEM. A frequency-shaped H2 methodology was developed, allowing the designer to specify the roll-off of the MIMO compensator. A closed loop bandwidth of 4 Hz, including the six rigid body modes and the first three dominant elastic modes of the CEM was achieved. Good agreement was demonstrated between experimental data and analytical predictions for the closed loop frequency response and random tests. Using the Modal Strain Energy (MSE) method, a passive damping treatment consisting of 60 viscoelastically damped struts was designed, fabricated and implemented on the CEM. Damping levels for the targeted modes were more than an order of magnitude larger than for the undamped structure. Using measured loss and stiffness data for the individual damped struts, analytical predictions of the damping levels were very close to the experimental values in the (1-10) Hz frequency range where the open loop model matched the experimental data. An integrated active/passive controller was successfully implemented on the CEM and was evaluated against an active-only controller. A two-fold increase in the effective control bandwidth and further reductions of 30 percent to 50 percent in the LOS RMS outputs were achieved compared to an active-only controller. Superior performance was also obtained compared to a High-Authority/Low-Authority (HAC/LAC) controller.

  13. BiOBr@SiO2 flower-like nanospheres chemically-bonded on cement-based materials for photocatalysis

    NASA Astrophysics Data System (ADS)

    Wang, Dan; Hou, Pengkun; Yang, Ping; Cheng, Xin

    2018-02-01

    Endowment of photocatalytic property on the surface of concrete structure can contribute to the self-cleaning of the structure and purification of the polluted environment. We developed a nano-structured BiOBr@SiO2 photocatalyst and innovatively used for surface-treatment of cement-based materials with the hope of attaining the photocatalytic property in visible-light region and surface modification/densification performances. The SiO2 layer on the flower-like BiOBr@SiO2 helps to maintain a stable distribution of the photocatalyst, as well as achieving a chemical bonding between the coating and the cement matrix. Results showed that the color fading rate of during the degradation of Rhodamine B dye of the BiOBr-cem sample is 2 times higher compared with the commonly studied C, N-TiO2-cem sample. The photo-degradation rates of samples BiOBr-cem and BiOBr@SiO2-cem are 93 and 81% within 150 min, respectively, while sample BiOBr@SiO2-cem reveals a denser and smoother surface after curing for 28 days and pore-filling effect at size within 0.01-0.2 μm when compared with untreated samples. Moreover, additional C-S-H gel can be formed due to the pozzolanic reaction between BiOBr@SiO2 and the hardened cement matrix. Both advantages of the BiOBr@SiO2 favor its application for surface-treatment of hardened cement-based material to acquire an improved surface quality, as well as durable photocatalytic functionality.

  14. Dental Resin Cements-The Influence of Water Sorption on Contraction Stress Changes and Hydroscopic Expansion.

    PubMed

    Sokolowski, Grzegorz; Szczesio, Agata; Bociong, Kinga; Kaluzinska, Karolina; Lapinska, Barbara; Sokolowski, Jerzy; Domarecka, Monika; Lukomska-Szymanska, Monika

    2018-06-08

    Resin matrix dental materials undergo contraction and expansion changes due to polymerization and water absorption. Both phenomena deform resin-dentin bonding and influence the stress state in restored tooth structure in two opposite directions. The study tested three composite resin cements (Cement-It, NX3, Variolink Esthetic DC), three adhesive resin cements (Estecem, Multilink Automix, Panavia 2.0), and seven self-adhesive resin cements (Breeze, Calibra Universal, MaxCem Elite Chroma, Panavia SA Cement Plus, RelyX U200, SmartCem 2, and SpeedCEM Plus). The stress generated at the restoration-tooth interface during water immersion was evaluated. The shrinkage stress was measured immediately after curing and after 0.5 h, 24 h, 72 h, 96 h, 168 h, 240 h, 336 h, 504 h, 672 h, and 1344 h by means of photoelastic study. Water sorption and solubility were also studied. All tested materials during polymerization generated shrinkage stress ranging from 4.8 MPa up to 15.1 MPa. The decrease in shrinkage strain (not less than 57%) was observed after water storage (56 days). Self-adhesive cements, i.e., MaxCem Elite Chroma, SpeedCem Plus, Panavia SA Plus, and Breeze exhibited high values of water expansion stress (from 0 up to almost 7 MPa). Among other tested materials only composite resin cement Cement It and adhesive resin cement Panavia 2.0 showed water expansion stress (1.6 and 4.8, respectively). The changes in stress value (decrease in contraction stress or built up of hydroscopic expansion) in time were material-dependent.

  15. Exploring robust methods for evaluating treatment and comparison groups in chronic care management programs.

    PubMed

    Wells, Aaron R; Hamar, Brent; Bradley, Chastity; Gandy, William M; Harrison, Patricia L; Sidney, James A; Coberley, Carter R; Rula, Elizabeth Y; Pope, James E

    2013-02-01

    Evaluation of chronic care management (CCM) programs is necessary to determine the behavioral, clinical, and financial value of the programs. Financial outcomes of members who are exposed to interventions (treatment group) typically are compared to those not exposed (comparison group) in a quasi-experimental study design. However, because member assignment is not randomized, outcomes reported from these designs may be biased or inefficient if study groups are not comparable or balanced prior to analysis. Two matching techniques used to achieve balanced groups are Propensity Score Matching (PSM) and Coarsened Exact Matching (CEM). Unlike PSM, CEM has been shown to yield estimates of causal (program) effects that are lowest in variance and bias for any given sample size. The objective of this case study was to provide a comprehensive comparison of these 2 matching methods within an evaluation of a CCM program administered to a large health plan during a 2-year time period. Descriptive and statistical methods were used to assess the level of balance between comparison and treatment members pre matching. Compared with PSM, CEM retained more members, achieved better balance between matched members, and resulted in a statistically insignificant Wald test statistic for group aggregation. In terms of program performance, the results showed an overall higher medical cost savings among treatment members matched using CEM compared with those matched using PSM (-$25.57 versus -$19.78, respectively). Collectively, the results suggest CEM is a viable alternative, if not the most appropriate matching method, to apply when evaluating CCM program performance.

  16. 40 CFR Appendix Ix to Part 266 - Methods Manual for Compliance With the BIF Regulations

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... However, it is more time-consuming and is recommended only if the basic approach fails to meet the risk... used to evaluate the acceptability of the CEMS at the time of its installation or whenever specified in regulations or permits. The procedures are not designed to evaluate CEMS performance over an extended period...

  17. 40 CFR Appendix Ix to Part 266 - Methods Manual for Compliance With the BIF Regulations

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... However, it is more time-consuming and is recommended only if the basic approach fails to meet the risk... used to evaluate the acceptability of the CEMS at the time of its installation or whenever specified in regulations or permits. The procedures are not designed to evaluate CEMS performance over an extended period...

  18. 40 CFR Appendix Ix to Part 266 - Methods Manual for Compliance With the BIF Regulations

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... However, it is more time-consuming and is recommended only if the basic approach fails to meet the risk... used to evaluate the acceptability of the CEMS at the time of its installation or whenever specified in regulations or permits. The procedures are not designed to evaluate CEMS performance over an extended period...

  19. 75 FR 81349 - Change to the Reporting Date for Certain Data Elements Required Under the Mandatory Reporting of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-27

    ... steel mills, steel companies, sinter plants, blast furnaces, basic oxygen process furnace shops. Lead... data or data that are less expensive to collect such as process data or material consumption data. For...)(1) Only annual anode consumption (No CEMS). F 98.66(f)(1) Only annual paste consumption (No CEMS). F...

  20. Synergistic properties of graphitic carbon nitride/cerium molybdate nanocomposites for enhanced photocatalytic activity

    NASA Astrophysics Data System (ADS)

    Bhargava, V. S.; Singh, Gajendar; Sharma, Manu

    2018-05-01

    A polymeric semiconductor (g-C3N4), based nanocomposites have been achieved much attention due to its excellent thermal, chemical stability and suitable band positions for water splitting. g-C3N4 based nanocomposites show good performance in the field of photocatalysis, sensors, Li-ion batteries, supercapacitors and water purification technology. In this work, a series of novel g-C3N4/CeM nano composites were synthesized using a facile one-step ultra-sonication method. X-ray diffraction (XRD) pattern confirms the formation of g-C3N4 and cerium molybdate. The photocatalytic activity of nanocomposites indicated the substantial degradation of Methylene Blue (MB) dye up to 97% over the surface of g-C3N4/CeM under visible light illumination. All the g-C3N4/CeM composites possess higher photocatalytic activity than pure cerium molybdate. The proposed mechanism demonstrated that the different weight ratios of photocatalyst were most likely attributed to a synergistic effect between g-C3N4 and CeM. This approach is very simple, cost effective, and free from any surfactant that makes it valuable catalyst for various future applications.

  1. Development of conceptual ecological models linking management of the Missouri River to pallid sturgeon population dynamics

    USGS Publications Warehouse

    Jacobson, Robert B.; Parsley, Michael J.; Annis, Mandy L.; Colvin, Michael E.; Welker, Timothy L.; James, Daniel A.

    2015-01-01

    This report documents the process of developing and refining conceptual ecological models (CEMs) for linking river management to pallid sturgeon (Scaphirhynchus albus) population dynamics in the Missouri River. The refined CEMs are being used in the Missouri River Pallid Sturgeon Effects Analysis to organize, document, and formalize an understanding of pallid sturgeon population responses to past and future management alternatives. The general form of the CEMs, represented by a population-level model and component life-stage models, was determined in workshops held in the summer of 2013. Subsequently, the Missouri River Pallid Sturgeon Effects Analysis team designed a general hierarchical structure for the component models, refined the graphical structure, and reconciled variation among the components and between models developed for the upper river (Upper Missouri & Yellowstone Rivers) and the lower river (Missouri River downstream from Gavins Point Dam). Importance scores attributed to the relations between primary biotic characteristics and survival were used to define a candidate set of working dominant hypotheses about pallid sturgeon population dynamics. These CEMs are intended to guide research and adaptive-management actions to benefit pallid sturgeon populations in the Missouri River.

  2. A Cell Line-Based Neutralization Assay for Primary Human Immunodeficiency Virus Type 1 Isolates That Use either the CCR5 or the CXCR4 Coreceptor

    PubMed Central

    Trkola, Alexandra; Matthews, Jamie; Gordon, Cynthia; Ketas, Tom; Moore, John P.

    1999-01-01

    We describe here a cell line-based assay for the evaluation of human immunodeficiency virus type 1 (HIV-1) neutralization. The assay is based on CEM.NKR cells, transfected to express the HIV-1 coreceptor CCR5 to supplement the endogenous expression of CD4 and the CXCR4 coreceptor. The resulting CEM.NKR-CCR5 cells efficiently replicate primary HIV-1 isolates of both R5 and X4 phenotypes. A comparison of the CEM.NKR-CCR5 cells with mitogen-activated peripheral blood mononuclear cells (PBMC) in neutralization assays with sera from HIV-1-infected individuals or specific anti-HIV-1 monoclonal antibodies shows that the sensitivity of HIV-1 neutralization is similar in the two cell types. The CEM.NKR-CCR5 cell assay, however, is more convenient to perform and eliminates the donor-to-donor variation in HIV-1 replication efficiency, which is one of the principal drawbacks of the PBMC-based neutralization assay. We suggest that this new assay is suitable for the general measurement of HIV-1 neutralization by antibodies. PMID:10516002

  3. 40 CFR 60.58a - Compliance and performance testing.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... period when the affected facility is combusting only a fossil fuel or other non-MSW fuel and no MSW is... to the atmosphere and record the output of the system. (7) Following the date of the initial..., and operate a CEMS for measuring nitrogen oxides discharged to the atmosphere and record the output of...

  4. 40 CFR 60.58a - Compliance and performance testing.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... period when the affected facility is combusting only a fossil fuel or other non-MSW fuel and no MSW is... to the atmosphere and record the output of the system. (7) Following the date of the initial..., and operate a CEMS for measuring nitrogen oxides discharged to the atmosphere and record the output of...

  5. 40 CFR 60.58a - Compliance and performance testing.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... period when the affected facility is combusting only a fossil fuel or other non-MSW fuel and no MSW is... to the atmosphere and record the output of the system. (7) Following the date of the initial..., and operate a CEMS for measuring nitrogen oxides discharged to the atmosphere and record the output of...

  6. 40 CFR 60.58a - Compliance and performance testing.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... period when the affected facility is combusting only a fossil fuel or other non-MSW fuel and no MSW is... to the atmosphere and record the output of the system. (7) Following the date of the initial..., and operate a CEMS for measuring nitrogen oxides discharged to the atmosphere and record the output of...

  7. 40 CFR 60.58a - Compliance and performance testing.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... period when the affected facility is combusting only a fossil fuel or other non-MSW fuel and no MSW is... to the atmosphere and record the output of the system. (7) Following the date of the initial..., and operate a CEMS for measuring nitrogen oxides discharged to the atmosphere and record the output of...

  8. 40 CFR 60.56c - Compliance and performance testing.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ....56c Section 60.56c Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... (defined oxygen correction basis); 20.9=oxygen concentration in air, percent; and %O2=oxygen concentration... compliance with the PM standards using bag leak detection systems as specified in § 60.57c(h) or PM CEMS as...

  9. 40 CFR 60.56c - Compliance and performance testing.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....56c Section 60.56c Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... (defined oxygen correction basis); 20.9=oxygen concentration in air, percent; and %O2=oxygen concentration... compliance with the PM standards using bag leak detection systems as specified in § 60.57c(h) or PM CEMS as...

  10. Martensitic phase transformations in the nanostructured surface layers induced by mechanical attrition treatment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ni Zhichun; Wang Xiaowei; Wu Erdong

    2005-12-01

    Conversion electron Moessbauer spectroscopy (CEMS) and x-ray diffraction (XRD) analysis have been used to investigate the relationship between characteristics of phase transformation and the treatment time in surface nanocrystallized 316L stainless steel induced by surface mechanical attrition treatment (SMAT). A similar trend of development of the martensitic phase upon the treatment time has been observed from both CEMS and XRD measurements. However, in the CEMS measurement, two types of martensite phase with different magnetic hyperfine fields are revealed. Based on a random distribution of the non-iron coordinating atoms, a three-element theoretical model is developed to illustrate the difference of twomore » types of martensite phase. The calculated results indicate the segregation of the non-iron atoms associated with SMAT treatment.« less

  11. Use of electroporation to study the cytotoxic effects of fluorodeoxyuridylate in intact cells.

    PubMed

    Jastreboff, M M; Sokoloski, J A; Bertino, J R; Narayanan, R

    1987-04-15

    The introduction of 2'-deoxyuridine 5'-monophosphate and its analog, 5-fluoro-2'-deoxyuridine 5'-monophosphate, into intact CCRF-CEM and NIH3T3 cells was achieved by electroporation. Following electroporation, cells were shown to be fully functional as monitored by the incorporation of deoxyuridylate, after conversion to thymidylate, into DNA. Pretreatment of cells with fluorodeoxyuridine completely abolished this effect. In contrast, introduction of the fluoro analog into cells by electroporation markedly inhibited both DNA synthesis and cell growth in a time-dependent manner. Thus, electroporation offers a powerful tool to permeabilize cells to a variety of cellular metabolites and antimetabolites.

  12. Acquisition Management for System of Systems: Requirement Evolution and Acquisition Strategy Planning

    DTIC Science & Technology

    2013-01-29

    of modern portfolio and control theory . The reformulation allows for possible changes in estimated quantities (e.g., due to market shifts in... Portfolio Theory (MPT). Final Report: NPS award N00244-11-1-0003 5 Extending CEM and Markov: Agent-Based Modeling Approach Research conducted in the...integration and acquisition from a robust portfolio theory standpoint. Robust portfolio management methodologies have been widely used by financial

  13. Alterations of mitochondrial DNA in CEM cells selected for resistance toward ddC toxicity.

    PubMed

    Bjerke, M; Franco, M; Johansson, M; Balzarini, J; Karlsson, A

    2006-01-01

    2 ',3 '-dideoxycytidine (ddC) is a nucleoside analog that has been shown to produce a delayed toxicity which may be due to the depletion of mitochondrial DNA (mtDNA). In order to gain further understanding of the events involved in mitochondrial toxicity, two different CEM cell lines were selected for resistance to the delayed ddC toxicity.

  14. The Women's Studies Center--A Women's-Led NGO Deepening Democracy in Chile: Educating Women through Personal Empowerment and Political Agency.

    ERIC Educational Resources Information Center

    King, Caroline

    This paper explores how the Women's Studies Center (Centro de Estudios de la Mujer, CEM), a feminist, women-led nongovernmental organization (NGO), is contributing to socio-cultural change in Chile 11 years after the country's democratic transition. CEM merges the theoretical and the practical, and the personal and the political through education…

  15. The development and validation of the client expectations of massage scale.

    PubMed

    Boulanger, Karen T; Campo, Shelly; Glanville, Jennifer L; Lowe, John B; Yang, Jingzhen

    2012-01-01

    Although there is evidence that client expectations influence client outcomes, a valid and reliable scale for measuring the range of client expectations for both massage therapy and the behaviors of their massage therapists does not exist. Understanding how client expectations influence client outcomes would provide insight into how massage achieves its reported effects. To develop and validate the Client Expectations of Massage Scale (CEMS), a measure of clients' clinical, educational, interpersonal, and outcome expectations. Offices of licensed massage therapists in Iowa. A practice-based research methodology was used to collect data from two samples of massage therapy clients. For Sample 1, 21 volunteer massage therapists collected data from their clients before the massage. Factor analysis was conducted to test construct validity and coefficient alpha was used to assess reliability. Correlational analyses with the CEMS, previous measures of client expectations, and the Life Orientation Test-Revised were examined to test the convergent and discriminant validity of the CEMS. For Sample 2, 24 massage therapists distributed study materials for clients to complete before and after a massage therapy session. Structural equation modeling was used to assess the construct, discriminant, and predictive validity of the CEMS. Sample 1 involved 320 and Sample 2 involved 321 adult massage clients. Standard care provided by licensed massage therapists. Numeric Rating Scale for pain and Positive and Negative Affect Schedule-Revised (including the Serenity subscale). The CEMS demonstrated good construct, convergent, discriminant and predictive validity, and adequate reliability. Client expectations were generally positive toward massage and their massage therapists. Positive outcome expectations had a positive effect on clients' changes in pain and serenity. High interpersonal expectations had a negative effect on clients' changes in serenity. Client expectations contribute to the nonspecific effects of massage therapy.

  16. Quantifying Nanoparticle Internalization Using a High Throughput Internalization Assay.

    PubMed

    Mann, Sarah K; Czuba, Ewa; Selby, Laura I; Such, Georgina K; Johnston, Angus P R

    2016-10-01

    The internalization of nanoparticles into cells is critical for effective nanoparticle mediated drug delivery. To investigate the kinetics and mechanism of internalization of nanoparticles into cells we have developed a DNA molecular sensor, termed the Specific Hybridization Internalization Probe - SHIP. Self-assembling polymeric 'pHlexi' nanoparticles were functionalized with a Fluorescent Internalization Probe (FIP) and the interactions with two different cell lines (3T3 and CEM cells) were studied. The kinetics of internalization were quantified and chemical inhibitors that inhibited energy dependent endocytosis (sodium azide), dynamin dependent endocytosis (Dyngo-4a) and macropinocytosis (5-(N-ethyl-N-isopropyl) amiloride (EIPA)) were used to study the mechanism of internalization. Nanoparticle internalization kinetics were significantly faster in 3T3 cells than CEM cells. We have shown that ~90% of the nanoparticles associated with 3T3 cells were internalized, compared to only 20% of the nanoparticles associated with CEM cells. Nanoparticle uptake was via a dynamin-dependent pathway, and the nanoparticles were trafficked to lysosomal compartments once internalized. SHIP is able to distinguish between nanoparticles that are associated on the outer cell membrane from nanoparticles that are internalized. This study demonstrates the assay can be used to probe the kinetics of nanoparticle internalization and the mechanisms by which the nanoparticles are taken up by cells. This information is fundamental for engineering more effective nanoparticle delivery systems. The SHIP assay is a simple and a high-throughput technique that could have wide application in therapeutic delivery research.

  17. A synopsis of test results and knowledge gained from the Phase-0 CSI evolutionary model

    NASA Technical Reports Server (NTRS)

    Belvin, W. Keith; Elliott, Kenny B.; Horta, Lucas G.

    1993-01-01

    The Phase-0 CSI Evolutionary Model (CEM) is a testbed for the study of space platform global line-of-sight (LOS) pointing. Now that the tests have been completed, a summary of hardware and closed-loop test experiences is necessary to insure a timely dissemination of the knowledge gained. The testbed is described and modeling experiences are presented followed by a summary of the research performed by various investigators. Some early lessons on implementing the closed-loop controllers are described with particular emphasis on real-time computing requirements. A summary of closed-loop studies and a synopsis of test results are presented. Plans for evolving the CEM from phase 0 to phases 1 and 2 are also described. Subsequently, a summary of knowledge gained from the design and testing of the Phase-0 CEM is made.

  18. Publications - PDF 95-33D | Alaska Division of Geological & Geophysical

    Science.gov Websites

    D-1, C-1, and part of the B-1 quadrangles, east-central Alaska Authors: Pinney, D.S., Clough, J.G ., Reifenstuhl, R.R., and Liss, S.A., 1995, Derivative geologic materials map of the Charley River D-1, C-1, and part of the B-1 quadrangles, east-central Alaska: Alaska Division of Geological & Geophysical

  19. 40 CFR Table 8 to Subpart Aaaaa of... - Applicability of General Provisions to Subpart AAAAA

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Provisions to Subpart AAAAA As required in § 63.7140, you must comply with the applicable General Provisions...)(5)(v) Opacity/VE Standards Yes § 63.6(h)(6) Opacity/VE Standards Yes § 63.6(h)(7) COM Use Yes § 63.6...) Cycle Time for COM and CEMS Yes No CEMS are required under subpart AAAAA; see § 63.7113 for CPMS...

  20. Ceramic Electron Multiplier

    DOE PAGES

    Comby, G.

    1996-10-01

    The Ceramic Electron Multipliers (CEM) is a compact, robust, linear and fast multi-channel electron multiplier. The Multi Layer Ceramic Technique (MLCT) allows to build metallic dynodes inside a compact ceramic block. The activation of the metallic dynodes enhances their secondary electron emission (SEE). The CEM can be used in multi-channel photomultipliers, multi-channel light intensifiers, ion detection, spectroscopy, analysis of time of flight events, particle detection or Cherenkov imaging detectors. (auth)

  1. A capillary electrophoresis coupled to mass spectrometry pipeline for long term comparable assessment of the urinary metabolome.

    PubMed

    Boizard, Franck; Brunchault, Valérie; Moulos, Panagiotis; Breuil, Benjamin; Klein, Julie; Lounis, Nadia; Caubet, Cécile; Tellier, Stéphanie; Bascands, Jean-Loup; Decramer, Stéphane; Schanstra, Joost P; Buffin-Meyer, Bénédicte

    2016-10-03

    Although capillary electrophoresis coupled to mass spectrometry (CE-MS) has potential application in the field of metabolite profiling, very few studies actually used CE-MS to identify clinically useful body fluid metabolites. Here we present an optimized CE-MS setup and analysis pipeline to reproducibly explore the metabolite content of urine. We show that the use of a beveled tip capillary improves the sensitivity of detection over a flat tip. We also present a novel normalization procedure based on the use of endogenous stable urinary metabolites identified in the combined metabolome of 75 different urine samples from healthy and diseased individuals. This method allows a highly reproducible comparison of the same sample analyzed nearly 130 times over a range of 4 years. To demonstrate the use of this pipeline in clinical research we compared the urinary metabolome of 34 newborns with ureteropelvic junction (UPJ) obstruction and 15 healthy newborns. We identified 32 features with differential urinary abundance. Combination of the 32 compounds in a SVM classifier predicted with 76% sensitivity and 86% specificity UPJ obstruction in a separate validation cohort of 24 individuals. Thus, this study demonstrates the feasibility to use CE-MS as a tool for the identification of clinically relevant urinary metabolites.

  2. Contour Error Map Algorithm

    NASA Technical Reports Server (NTRS)

    Merceret, Francis; Lane, John; Immer, Christopher; Case, Jonathan; Manobianco, John

    2005-01-01

    The contour error map (CEM) algorithm and the software that implements the algorithm are means of quantifying correlations between sets of time-varying data that are binarized and registered on spatial grids. The present version of the software is intended for use in evaluating numerical weather forecasts against observational sea-breeze data. In cases in which observational data come from off-grid stations, it is necessary to preprocess the observational data to transform them into gridded data. First, the wind direction is gridded and binarized so that D(i,j;n) is the input to CEM based on forecast data and d(i,j;n) is the input to CEM based on gridded observational data. Here, i and j are spatial indices representing 1.25-km intervals along the west-to-east and south-to-north directions, respectively; and n is a time index representing 5-minute intervals. A binary value of D or d = 0 corresponds to an offshore wind, whereas a value of D or d = 1 corresponds to an onshore wind. CEM includes two notable subalgorithms: One identifies and verifies sea-breeze boundaries; the other, which can be invoked optionally, performs an image-erosion function for the purpose of attempting to eliminate river-breeze contributions in the wind fields.

  3. Power System Challenge: Synthesis Report for the 7th Clean Energy Ministerial

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None, None

    The Clean Energy Ministerial's (CEM's) Power System Challenge was established in 2015 to create a shared vision among major economies regarding the pathway to clean, reliable, resilient, and affordable power. Endorsing governments have created core principles and challenge propositions as a framework for government and industry action to support and guide power system transformation. This brochure details the status of the Challenge, how countries are working to meet the Challenge, and the relevant milestones reached by initiatives of the Clean Energy Ministerial.

  4. Tectonic and volcanic monitoring using Sentinel-1: Current status and future plans of the COMET InSAR portal

    NASA Astrophysics Data System (ADS)

    Spaans, Karsten; Hatton, Emma; Gonzalez, Pablo; Walters, Richard; McDougall, Alistair; Wright, Tim; Hooper, Andy

    2017-04-01

    The advantages of the Sentinel-1 constellation for InSAR applications over previous radar missions are numerous, and include small baselines, a planned operation time of 20 years, continuous and systematic acquisition of data over tectonic and volcanic areas, near-global coverage of the earth and free data availability. In order to take advantage of these properties, we at the Centre for the Observation and Modelling of Earthquakes, Volcanoes, and Tectonics (COMET) are developing a system that routinely processes and freely distributes interferometric products and time series over tectonic and volcanic regions. This project, and similar efforts at other institutions, will be a game changer for the monitoring and studying of tectonic and volcanic activity using InSAR. Since December 2016, the COMET-LiCS InSAR portal (http://comet.nerc.ac.uk/COMET-LiCS-portal/) has been live, delivering interferograms and coherence estimates over the entire Alpine-Himalayan belt. The portal already contains tens of thousands of products, which can be browsed in a user-friendly portal, and downloaded for free by the general public. For our processing, we use the Climate and Environmental Monitoring from Space (CEMS) facility, where we have large storage and processing facilities to our disposal and a complete duplicate of the Sentinel-1 archive is maintained. This greatly simplifies the infrastructure we have had to develop for automated processing of large areas. Here we will give an overview of the current status of the processing system, as well as discuss future plans. We will cover the infrastructure we developed to automatically produce interferograms and its challenges, and the processing strategy for time series analysis. We will outline the objectives of the system in the near and distant future, and a roadmap for its continued development. Finally, we will highlight some of the scientific results and projects linked to the system.

  5. Publications - PDF 95-33C | Alaska Division of Geological & Geophysical

    Science.gov Websites

    content DGGS PDF 95-33C Publication Details Title: Surficial geologic map of the Charley River D-1, C-1 , and part of the B-1 quadrangles, east-central Alaska Authors: Pinney, D.S., Clough, J.G., and Liss ., 1995, Surficial geologic map of the Charley River D-1, C-1, and part of the B-1 quadrangles, east

  6. Publications - PDF 95-33B | Alaska Division of Geological & Geophysical

    Science.gov Websites

    D-1, C-1, and part of the B-1 quadrangles, east-central Alaska Authors: Clough, J.G., Mull, C.G , Interpretive bedrock geologic map of the Charley River D-1, C-1, and part of the B-1 quadrangles, east-central 1:63,360. http://doi.org/10.14509/1713 Publication Products Maps & Other Oversized Sheets Maps

  7. Space Station UCS antenna pattern computation and measurement. [UHF Communication Subsystem

    NASA Technical Reports Server (NTRS)

    Hwu, Shian U.; Lu, Ba P.; Johnson, Larry A.; Fournet, Jon S.; Panneton, Robert J.; Ngo, John D.; Eggers, Donald S.; Arndt, G. D.

    1993-01-01

    The purpose of this paper is to analyze the interference to the Space Station Ultrahigh Frequency (UHF) Communication Subsystem (UCS) antenna radiation pattern due to its environment - Space Station. A hybrid Computational Electromagnetics (CEM) technique was applied in this study. The antenna was modeled using the Method of Moments (MOM) and the radiation patterns were computed using the Uniform Geometrical Theory of Diffraction (GTD) in which the effects of the reflected and diffracted fields from surfaces, edges, and vertices of the Space Station structures were included. In order to validate the CEM techniques, and to provide confidence in the computer-generated results, a comparison with experimental measurements was made for a 1/15 scale Space Station mockup. Based on the results accomplished, good agreement on experimental and computed results was obtained. The computed results using the CEM techniques for the Space Station UCS antenna pattern predictions have been validated.

  8. The Langley Research Center CSI phase-0 evolutionary model testbed-design and experimental results

    NASA Technical Reports Server (NTRS)

    Belvin, W. K.; Horta, Lucas G.; Elliott, K. B.

    1991-01-01

    A testbed for the development of Controls Structures Interaction (CSI) technology is described. The design philosophy, capabilities, and early experimental results are presented to introduce some of the ongoing CSI research at NASA-Langley. The testbed, referred to as the Phase 0 version of the CSI Evolutionary model (CEM), is the first stage of model complexity designed to show the benefits of CSI technology and to identify weaknesses in current capabilities. Early closed loop test results have shown non-model based controllers can provide an order of magnitude increase in damping in the first few flexible vibration modes. Model based controllers for higher performance will need to be robust to model uncertainty as verified by System ID tests. Data are presented that show finite element model predictions of frequency differ from those obtained from tests. Plans are also presented for evolution of the CEM to study integrated controller and structure design as well as multiple payload dynamics.

  9. Management by Objectives. ACSA School Management Digest, Series 1, No. 6. ERIC/CEM Research Analysis Series, Number 33.

    ERIC Educational Resources Information Center

    Dunn, Pierre

    This review of the literature briefly outlines the history of management by objectives (MBO), describing the Madison, Wisconsin, school district's application of this systems approach to school management, as well as alternatives to the Madison MBO plan developed by other districts across the country. Although there are many variations of MBO and…

  10. Modulation of P-glycoprotein activity by novel synthetic curcumin derivatives in sensitive and multidrug-resistant T-cell acute lymphoblastic leukemia cell lines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ooko, Edna

    Background: Multidrug resistance (MDR) and drug transporter P-glycoprotein (P-gp) represent major obstacles in cancer chemotherapy. We investigated 19 synthetic curcumin derivatives in drug-sensitive acute lymphoblastic CCRF–CEM leukemia cells and their multidrug-resistant P-gp-overexpressing subline, CEM/ADR5000. Material and methods: Cytotoxicity was tested by resazurin assays. Doxorubicin uptake was assessed by flow cytometry. Binding modes of compounds to P-gp were analyzed by molecular docking. Chemical features responsible for bioactivity were studied by quantitative structure activity relationship (QSAR) analyses. A 7-descriptor QSAR model was correlated with doxorubicin uptake values, IC{sub 50} values and binding energies. Results: The compounds displayed IC{sub 50} values between 0.7more » ± 0.03 and 20.2 ± 0.25 μM. CEM/ADR5000 cells exhibited cross-resistance to 10 compounds, collateral sensitivity to three compounds and regular sensitivity to the remaining six curcumins. Molecular docking studies at the intra-channel transmembrane domain of human P-gp resulted in lowest binding energies ranging from − 9.00 ± 0.10 to − 6.20 ± 0.02 kcal/mol and pKi values from 0.24 ± 0.04 to 29.17 ± 0.88 μM. At the ATP-binding site of P-gp, lowest binding energies ranged from − 9.78 ± 0.17 to − 6.79 ± 0.01 kcal/mol and pKi values from 0.07 ± 0.02 to 0.03 ± 0.03 μM. CEM/ADR5000 cells accumulated approximately 4-fold less doxorubicin than CCRF–CEM cells. The control P-gp inhibitor, verapamil, partially increased doxorubicin uptake in CEM/ADR5000 cells. Six curcumins increased doxorubicin uptake in resistant cells or even exceeded uptake levels compared to sensitive one. QSAR yielded good activity prediction (R = 0.797 and R = 0.794 for training and test sets). Conclusion: Selected derivatives may serve to guide future design of novel P-gp inhibitors and collateral sensitive drugs to combat MDR. - Highlights: • Novel derivatives of curcumin in reversing multidrug resistance (MDR) • Biological and Insilco assays to assess effect on P-glycoprotein (P-gp) • Curcumin synthetic derivatives as possible lead compound against multidrug resistant cancer.« less

  11. Effect of thermocycling with or without 1 year of water storage on retentive strengths of luting cements for zirconia crowns.

    PubMed

    Ehlers, Vicky; Kampf, Gabriel; Stender, Elmar; Willershausen, Brita; Ernst, Claus-Peter

    2015-06-01

    Bond stability between zirconia crowns and luting cement and between cement and dentin is a main concern; however, only limited evidence is available as to its longevity. The purpose of this in vitro study was to measure the retentive strengths of 7 self-adhesive cements (RelyX Unicem Aplicap, RelyX Unicem Clicker, RelyX Unicem 2 Automix, iCEM, Maxcem Elite, Bifix SE, SpeedCem), 2 adhesive cements with self-etch primers (Panavia 21, SEcure), 1 glass ionomer cement (Ketac Cem), 1 resin-modified glass ionomer cement (Meron Plus), and 1 zinc phosphate cement for luting zirconia crowns (LAVA) to extracted teeth after thermocycling with or without 1 year of water storage. Two-hundred-forty extracted human molars (2 treatments; n=10 per cement) were prepared in a standardized manner. All cements were used according to the manufacturers' recommendations. The intaglios of the crowns were treated with airborne-particle abrasion. After thermocycling (×5000, 5°C/55°C) with or without 1 year of water storage, the cemented ceramic crowns were removed by using a Zwick universal testing device. Statistical analyses were done with the Wilcoxon rank sum and the 2-independent-samples Kolmogorov-Smirnov test. Median retentive strengths [MPa] for specimens thermocycled only/thermocycled with 1 year of water storage were as follows: Panavia 21: 1.7/2.5, SEcure: 3.0/3.0, RelyX Unicem Aplicap: 3.1/3.4, RelyX Unicem Clicker: 4.1/4.2, RelyX Unicem 2 Automix: 3.8/3.1, iCEM: 2.3/2.7, Maxcem Elite: 3.0/3.2, Bifix SE: 1.7/1.7, SpeedCem: 1.3/1.6, Meron Plus: 3.1/2.7, Ketac Cem: 1.4/1.4, and zinc phosphate cement: 1.1/1.6. Statistically significant differences were found only among specimens thermocycled only or thermocycled with 1-year water storage (P<.001). Significant differences in retentive strengths were observed among cements after thermocycling only or thermocycling with 1 year of water storage, but not for the effect of the additional 1 year of water storage. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  12. Microleakage of Four Dental Cements in Metal Ceramic Restorations With Open Margins.

    PubMed

    Eftekhar Ashtiani, Reza; Farzaneh, Babak; Azarsina, Mohadese; Aghdashi, Farzad; Dehghani, Nima; Afshari, Aisooda; Mahshid, Minu

    2015-11-01

    Fixed prosthodontics is a routine dental treatment and microleakage is a major cause of its failure. The aim of this study was to assess the marginal microleakage of four cements in metal ceramic restorations with adapted and open margins. Sixty sound human premolars were selected for this experimental study performed in Tehran, Iran and prepared for full-crown restorations. Wax patterns were formed leaving a 300 µm gap on one of the proximal margins. The crowns were cast and the samples were randomly divided into four groups based on the cement used. Copings were cemented using zinc phosphate cement (Fleck), Fuji Plus resin-modified glass ionomer, Panavia F2.0 resin cement, or G-Cem resin cement, according to the manufacturers' instructions. Samples were immersed in 2% methylene blue solution. After 24 hours, dye penetration was assessed under a stereomicroscope and analyzed using the respective software. Data were analyzed using ANOVA, paired t-tests, and Kruskal-Wallis, Wilcoxon, and Mann-Whitney tests. The least microleakage occurred in the Panavia F2.0 group (closed margin, 0.18 mm; open margin, 0.64 mm) and the maximum was observed in the Fleck group (closed margin, 1.92 mm; open margin, 3.32 mm). The Fleck group displayed significantly more microleakage compared to the Fuji Plus and Panavia F2.0 groups (P < 0.001) in both closed and open margins. In open margins, differences in microleakage between the Fuji Plus and G-Cem as well as between the G-Cem and Panavia F2.0 groups were significant (P < 0.001). In closed margins, only the G-Cem group displayed significantly more microleakage as compared to the Panavia F2.0 group (P < 0.05). Paired t-test results showed significantly more microleakage in open margins compared to closed margins, except in the Fuji Plus group (P = 0.539). Fuji Plus cement exhibited better sealing ability in closed and open margins compared to G-Cem and Fleck cements. When using G-Cem and Fleck cements for full metal ceramic restorations, clinicians should try to minimize marginal gaps in order to reduce restoration failure. In situations where there are doubts about perfect marginal adaptation, the use of Fuji Plus cement may be helpful.

  13. 40 CFR Table 1 to Subpart Ddddd of... - Emission Limits for New or Reconstructed Boilers and Process Heaters

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... fossil fuel a. Filterable PM (or TSM) 1.1E-03 lb per MMBtu of heat input; or (2.3E-05 lb per MMBtu of... designed to burn coal/solid fossil fuel a. Carbon monoxide (CO) (or CEMS) 130 ppm by volume on a dry basis... minimum sampling time. 4. Stokers designed to burn coal/solid fossil fuel a. CO (or CEMS) 130 ppm by...

  14. Publications - PDF 95-33E | Alaska Division of Geological & Geophysical

    Science.gov Websites

    content DGGS PDF 95-33E Publication Details Title: Geologic hazards map of the Charley River D-1, C-1, and part of the B-1 quadrangles, east-central Alaska Authors: Pinney, D.S., Clough, J.G., Reifenstuhl, R.R ., Reifenstuhl, R.R., and Liss, S.A., 1995, Geologic hazards map of the Charley River D-1, C-1, and part of the B

  15. CE-MS analysis of heroin and its basic impurities using a charged polymer-protected gold nanoparticle-coated capillary.

    PubMed

    Zhang, Zhengxiang; Yan, Bo; Liu, Kelin; Liao, Yiping; Liu, Huwei

    2009-01-01

    The first application of charged polymer-protected gold nanoparticles (Au NPs) as semi-permanent capillary coating in CE-MS was presented. Poly(diallyldimethylammonium chloride) (PDDA) was the only reducing and stabilizing agent for Au NPs preparation. Stable and repeatable coating with good tolerance to 0.1 M HCl, methanol, and ACN was obtained via a simple rinsing procedure. Au NPs enhanced the coating stability toward flushing by methanol, improved the run-to-run and capillary-to-capillary repeatabilities, and improved the separation efficiency of heroin and its basic impurities for tracing geographical origins of illicit samples. Baseline resolution of eight heroin-related alkaloids was achieved on the PDDA-protected Au NPs-coated capillary under the optimum conditions: 120 mM ammonium acetate (pH 5.2) with addition of 13% methanol, separation temperature 20 degrees C, applied voltage -20 kV, and capillary effective length 60.0 cm. CE-MS analysis with run-to-run RSDs (n=5) of migration time in the range of 0.43-0.62% and RSDs (n=5) of peak area in the range of 1.49-4.68% was obtained. The established CE-MS method would offer sensitive detection and confident identification of heroin and related compounds and provide an alternative to LC-MS and GC-MS for illicit drug control.

  16. High-dose Carboplatin/Etoposide/Melphalan increases risk of thrombotic microangiopathy and organ injury after autologous stem cell transplantation in patients with neuroblastoma.

    PubMed

    Jodele, Sonata; Dandoy, Christopher E; Myers, Kasiani; Wallace, Gregory; Lane, Adam; Teusink-Cross, Ashley; Weiss, Brian; Davies, Stella M

    2018-04-19

    Transplant-associated thrombotic microangiopathy (TA-TMA) is an increasingly recognized complication of hematopoietic cell transplant that can result in multi-organ failure (MOF). Patients undergoing high-dose chemotherapy with autologous stem cell transplant (aHCT) for neuroblastoma require good organ function to receive post-transplant radiation and immunotherapy. We examined TA-TMA incidence and transplant outcomes in patients with neuroblastoma receiving different transplant preparative regimens. Sixty patients underwent aHCT using high-dose chemotherapy: 41 patients received carboplatin/etoposide/melphalan (CEM), 13 patients busulfan/melphalan (Bu/Mel) and six patients received tandem transplant (cyclophosphamide/thiotepa and CEM). TA-TMA with MOF was diagnosed in 13 patients (21.7%) at a median of 18 days after aHCT. TA-TMA occurred in 12 patients receiving CEM and in 1 after cyclophosphamide/thiotepa. There were no incidences of TA-TMA after Bu/Mel regimen. Six of 13 patients with TA-TMA and MOF received terminal complement blocker eculizumab for therapy. They all recovered organ function and received planned post-transplant therapy. Out of seven patients who did not get eculizumab, two died from TA-TMA complications and four progressed to ESRD. We conclude that the CEM regimen is associated with a high incidence of clinically significant TA-TMA after aHCT and eculizumab can be safe and effective treatment option to remediate TA-TMA associated MOF.

  17. Effect of cAMP signaling on expression of glucocorticoid receptor, Bim and Bad in glucocorticoid-sensitive and resistant leukemic and multiple myeloma cells.

    PubMed

    Dong, Hongli; Carlton, Michael E; Lerner, Adam; Epstein, Paul M

    2015-01-01

    Stimulation of cAMP signaling induces apoptosis in glucocorticoid-sensitive and resistant CEM leukemic and MM.1 multiple myeloma cell lines, and this effect is enhanced by dexamethasone in both glucocorticoid-sensitive cell types and in glucocorticoid-resistant CEM cells. Expression of the mRNA for the glucocorticoid receptor alpha (GR) promoters 1A3, 1B and 1C, expression of mRNA and protein for GR, and the BH3-only proapoptotic proteins, Bim and Bad, and the phosphorylation state of Bad were examined following stimulation of the cAMP and glucocorticoid signaling pathways. Expression levels of GR promoters were increased by cAMP and glucocorticoid signaling, but GR protein expression was little changed in CEM and decreased in MM.1 cells. Stimulation of these two signaling pathways induced Bim in CEM cells, induced Bad in MM.1 cells, and activated Bad, as indicated by its dephosphorylation on ser112, in both cell types. This study shows that leukemic and multiple myeloma cells, including those resistant to glucocorticoids, can be induced to undergo apoptosis by stimulating the cAMP signaling pathway, with enhancement by glucocorticoids, and the mechanism by which this occurs may be related to changes in Bim and Bad expression, and in all cases, to activation of Bad.

  18. A Conceptual Model of Natural and Anthropogenic Drivers and Their Influence on the Prince William Sound, Alaska, Ecosystem

    PubMed Central

    Harwell, Mark A.; Gentile, John H.; Cummins, Kenneth W.; Highsmith, Raymond C.; Hilborn, Ray; McRoy, C. Peter; Parrish, Julia; Weingartner, Thomas

    2010-01-01

    Prince William Sound (PWS) is a semi-enclosed fjord estuary on the coast of Alaska adjoining the northern Gulf of Alaska (GOA). PWS is highly productive and diverse, with primary productivity strongly coupled to nutrient dynamics driven by variability in the climate and oceanography of the GOA and North Pacific Ocean. The pelagic and nearshore primary productivity supports a complex and diverse trophic structure, including large populations of forage and large fish that support many species of marine birds and mammals. High intra-annual, inter-annual, and interdecadal variability in climatic and oceanographic processes as drives high variability in the biological populations. A risk-based conceptual ecosystem model (CEM) is presented describing the natural processes, anthropogenic drivers, and resultant stressors that affect PWS, including stressors caused by the Great Alaska Earthquake of 1964 and the Exxon Valdez oil spill of 1989. A trophodynamic model incorporating PWS valued ecosystem components is integrated into the CEM. By representing the relative strengths of driver/stressors/effects, the CEM graphically demonstrates the fundamental dynamics of the PWS ecosystem, the natural forces that control the ecological condition of the Sound, and the relative contribution of natural processes and human activities to the health of the ecosystem. The CEM illustrates the dominance of natural processes in shaping the structure and functioning of the GOA and PWS ecosystems. PMID:20862192

  19. Knowledge Transfer Project: Cultivating Smart Energy Solutions through Dynamic Peer-to-Peer Learning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    As energy policy makers and professionals convene in the Oresund region for the 9th Annual Clean Energy Ministerial (CEM9), the global community is as united as ever around the common goal of accelerating the transition to global clean energy. Through sustained collective effort and thought leadership, CEM partners and stakeholders are systematically addressing the barriers to the widescale deployment of clean energy technologies. Pivotal to their progress is the efficient sharing and dissemination of knowledge. To address that need, the CEM-initiative International SmartGrid Action Network (ISGAN) launched the Knowledge Transfer Project (KTP) in March 2016 to capture, collect, and sharemore » knowledge about smart grid technologies among countries and key stakeholders. Building on ISGAN's experience with delivering deep-dive workshops, the KTP fosters meaningful international dialogue on smart grids with a focus on developing competence and building capacity. After a successful 2016 pilot project and two consecutive projects, each with a different focus and structure, the KTP has become an established practice that can support existing ISGAN or CEM initiatives. To accommodate different purposes, needs, and practical circumstances, ISGAN has adopted three basic models for delivering KTP workshops: Country-Centric, Multilateral, and Hybrid. This fact sheet describes each approach through case studies of workshops in Mexico, India, and Belgium, and invites new ideas and partners for future KTPs.« less

  20. Lessons learned in detailed clinical modeling at Intermountain Healthcare

    PubMed Central

    Oniki, Thomas A; Coyle, Joseph F; Parker, Craig G; Huff, Stanley M

    2014-01-01

    Background and objective Intermountain Healthcare has a long history of using coded terminology and detailed clinical models (DCMs) to govern storage of clinical data to facilitate decision support and semantic interoperability. The latest iteration of DCMs at Intermountain is called the clinical element model (CEM). We describe the lessons learned from our CEM efforts with regard to subjective decisions a modeler frequently needs to make in creating a CEM. We present insights and guidelines, but also describe situations in which use cases conflict with the guidelines. We propose strategies that can help reconcile the conflicts. The hope is that these lessons will be helpful to others who are developing and maintaining DCMs in order to promote sharing and interoperability. Methods We have used the Clinical Element Modeling Language (CEML) to author approximately 5000 CEMs. Results Based on our experience, we have formulated guidelines to lead our modelers through the subjective decisions they need to make when authoring models. Reported here are guidelines regarding precoordination/postcoordination, dividing content between the model and the terminology, modeling logical attributes, and creating iso-semantic models. We place our lessons in context, exploring the potential benefits of an implementation layer, an iso-semantic modeling framework, and ontologic technologies. Conclusions We assert that detailed clinical models can advance interoperability and sharing, and that our guidelines, an implementation layer, and an iso-semantic framework will support our progress toward that goal. PMID:24993546

  1. A Conceptual Model of Natural and Anthropogenic Drivers and Their Influence on the Prince William Sound, Alaska, Ecosystem.

    PubMed

    Harwell, Mark A; Gentile, John H; Cummins, Kenneth W; Highsmith, Raymond C; Hilborn, Ray; McRoy, C Peter; Parrish, Julia; Weingartner, Thomas

    2010-07-01

    Prince William Sound (PWS) is a semi-enclosed fjord estuary on the coast of Alaska adjoining the northern Gulf of Alaska (GOA). PWS is highly productive and diverse, with primary productivity strongly coupled to nutrient dynamics driven by variability in the climate and oceanography of the GOA and North Pacific Ocean. The pelagic and nearshore primary productivity supports a complex and diverse trophic structure, including large populations of forage and large fish that support many species of marine birds and mammals. High intra-annual, inter-annual, and interdecadal variability in climatic and oceanographic processes as drives high variability in the biological populations. A risk-based conceptual ecosystem model (CEM) is presented describing the natural processes, anthropogenic drivers, and resultant stressors that affect PWS, including stressors caused by the Great Alaska Earthquake of 1964 and the Exxon Valdez oil spill of 1989. A trophodynamic model incorporating PWS valued ecosystem components is integrated into the CEM. By representing the relative strengths of driver/stressors/effects, the CEM graphically demonstrates the fundamental dynamics of the PWS ecosystem, the natural forces that control the ecological condition of the Sound, and the relative contribution of natural processes and human activities to the health of the ecosystem. The CEM illustrates the dominance of natural processes in shaping the structure and functioning of the GOA and PWS ecosystems.

  2. Tropospheric GOM at the Pic du Midi Observatory-Correcting Bias in Denuder Based Observations.

    PubMed

    Marusczak, Nicolas; Sonke, Jeroen E; Fu, Xuewu; Jiskra, Martin

    2017-01-17

    Gaseous elemental mercury (GEM, Hg) emissions are transformed to divalent reactive Hg (RM) forms throughout the troposphere and stratosphere. RM is often operationally quantified as the sum of particle bound Hg (PBM) and gaseous oxidized Hg (GOM). The measurement of GOM and PBM is challenging and under mounting criticism. Here we intercompare six months of automated GOM and PBM measurements using a Tekran (TK) KCl-coated denuder and quartz regenerable particulate filter method (GOM TK , PBM TK , and RM TK ) with RM CEM collected on cation exchange membranes (CEMs) at the high altitude Pic du Midi Observatory. We find that RM TK is systematically lower by a factor of 1.3 than RM CEM . We observe a significant relationship between GOM TK (but not PBM TK ) and Tekran flush TK blanks suggesting significant loss (36%) of labile GOM TK from the denuder or inlet. Adding the flush TK blank to RM TK results in good agreement with RM CEM (slope = 1.01, r 2 = 0.90) suggesting we can correct bias in RM TK and GOM TK . We provide a bias corrected (*) Pic du Midi data set for 2012-2014 that shows GOM* and RM* levels in dry free tropospheric air of 198 ± 57 and 229 ± 58 pg m -3 which agree well with in-flight observed RM and with model based GOM and RM estimates.

  3. Reducing CO2-Emission by using Eco-Cements

    NASA Astrophysics Data System (ADS)

    Voit, K.; Bergmeister, K.; Janotka, I.

    2012-04-01

    CO2 concentration in the air is rising constantly. Globally, cement companies are emitting nearly two billion tonnes/year of CO2 (or around 6 to 7 % of the planet's total CO2 emissions) by producing portland cement clinker. At this pace, by 2025 the cement industry will be emitting CO2 at a rate of 3.5 billion tones/year causing enormous environmental damage (Shi et al., 2011; Janotka et al., 2012). At the dawn of the industrial revolution in the mid-eighteenth century the concentration of CO2 was at a level of ca. 280 ppm. 200 years later at the time of World War II the CO2 level had risen to 310 ppm what results in a rate of increase of 0,15 ppm per year for that period (Shi et al., 2011). In November 2011 the CO2 concentration reached a value of 391 ppm (NOAA Earth System Research Laboratory, 2011), a rise of ca. 81 ppm in 66 years and an increased rate of around 1,2 ppm/year respectively. In the same period cement production in tons of cement has multiplied by a factor of ca. 62 (Kelly & Oss, US Geological Survey, 2010). Thus new CO2-saving eco-cement types are gaining in importance. In these cement types the energy-consuming portland cement clinker is partially replaced by latent hydraulic additives such as blast furnace slag, fly ash or zeolite. These hydraulic additives do not need to be fired in the rotary furnace. They ony need to be pulverized to the required grain size and added to the ground portland cement clinker. Hence energy is saved by skipping the engery-consuming firing process, in addition there is no CO2-degassing as there is in the case of lime burning. Therefore a research project between Austria and Slovakia, funded by the EU (Project ENVIZEO), was initiated in 2010. The main goal of this project is to develop new CEM V eco-types of cements and certificate them for common usage. CEM V is a portland clinker saving cement kind that allows the reduction of clinker to a proportion of 40-64% for CEM V/A and 20-39% for CEM V/B respectively by the input of slag sands, puzzolanes and fly ash (according to standard EN 197-1). In this context four new CEM V kinds have been created, two Austrian types based on slag and fly ash, and two Slovak types, one based on slag and fly ash, the other on slag and natural pozzolana. The pozzolana consist of zeolite of clinoptilolite type that is gained from a Slovak deposit.

  4. Comprehensive analysis of the MLH1 promoter region in 480 patients with colorectal cancer and 1150 controls reveals new variants including one with a heritable constitutional MLH1 epimutation.

    PubMed

    Morak, Monika; Ibisler, Ayseguel; Keller, Gisela; Jessen, Ellen; Laner, Andreas; Gonzales-Fassrainer, Daniela; Locher, Melanie; Massdorf, Trisari; Nissen, Anke M; Benet-Pagès, Anna; Holinski-Feder, Elke

    2018-04-01

    Germline defects in MLH1 , MSH2 , MSH6 and PMS2 predisposing for Lynch syndrome (LS) are mainly based on sequence changes, whereas a constitutional epimutation of MLH1 (CEM) is exceptionally rare. This abnormal MLH1 promoter methylation is not hereditary when arising de novo, whereas a stably heritable and variant-induced CEM was described for one single allele. We searched for MLH1 promoter variants causing a germline or somatic methylation induction or transcriptional repression. We analysed the MLH1 promoter sequence in five different patient groups with colorectal cancer (CRC) (n=480) composed of patients with i) CEM (n=16), ii) unsolved loss of MLH1 expression in CRC (n=37), iii) CpG-island methylator-phenotype CRC (n=102), iv) patients with LS (n=83) and v) MLH1-proficient CRC (n=242) as controls. 1150 patients with non-LS tumours also served as controls to correctly judge the results. We detected 10 rare MLH1 promoter variants. One novel, complex MLH1 variant c.-63_-58delins18 is present in a patient with CRC with CEM and his sister, both showing a complete allele-specific promoter methylation and transcriptional silencing. The other nine promoter variants detected in 17 individuals were not associated with methylation. For four of these, a normal, biallelic MLH1 expression was found in the patients' cDNA. We report the second promoter variant stably inducing a hereditary CEM. Concerning the classification of promoter variants, we discuss contradictory results from the literature for two variants, describe classification discrepancies between existing rules for five variants, suggest the (re-)classification of five promoter variants to (likely) benign and regard four variants as functionally unclear. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  5. Forward and inverse effects of the complete electrode model in neonatal EEG

    PubMed Central

    Lew, S.; Wolters, C. H.

    2016-01-01

    This paper investigates finite element method-based modeling in the context of neonatal electroencephalography (EEG). In particular, the focus lies on electrode boundary conditions. We compare the complete electrode model (CEM) with the point electrode model (PEM), which is the current standard in EEG. In the CEM, the voltage experienced by an electrode is modeled more realistically as the integral average of the potential distribution over its contact surface, whereas the PEM relies on a point value. Consequently, the CEM takes into account the subelectrode shunting currents, which are absent in the PEM. In this study, we aim to find out how the electrode voltage predicted by these two models differ, if standard size electrodes are attached to a head of a neonate. Additionally, we study voltages and voltage variation on electrode surfaces with two source locations: 1) next to the C6 electrode and 2) directly under the Fz electrode and the frontal fontanel. A realistic model of a neonatal head, including a skull with fontanels and sutures, is used. Based on the results, the forward simulation differences between CEM and PEM are in general small, but significant outliers can occur in the vicinity of the electrodes. The CEM can be considered as an integral part of the outer head model. The outcome of this study helps understanding volume conduction of neonatal EEG, since it enlightens the role of advanced skull and electrode modeling in forward and inverse computations. NEW & NOTEWORTHY The effect of the complete electrode model on electroencephalography forward and inverse computations is explored. A realistic neonatal head model, including a skull structure with fontanels and sutures, is used. The electrode and skull modeling differences are analyzed and compared with each other. The results suggest that the complete electrode model can be considered as an integral part of the outer head model. To achieve optimal source localization results, accurate electrode modeling might be necessary. PMID:27852731

  6. Comparison of capillary electrophoresis-mass spectrometry and hydrophilic interaction chromatography-mass spectrometry for anionic metabolic profiling of urine.

    PubMed

    Kok, Miranda G M; Somsen, Govert W; de Jong, Gerhardus J

    2015-01-01

    In order to assess the utility of a recently developed capillary electrophoresis-mass spectrometry (CE-MS) method for the study of anionic metabolites in urine, a comparison was made with hydrophilic interaction chromatography-MS (HILIC-MS) using negative electrospray ionization. After optimization of the HILIC conditions, a gradient employing 10mM ammonium acetate (pH 6.8) in acetonitrile-water (5 min 90% acetonitrile followed by 90%-50% acetonitrile in 10 min) was selected, providing baseline separation of five representative anionic test metabolites. Relative standard deviations (RSDs) for HILIC retention times and peak areas were below 0.2% and 7.7%, respectively, and detection limits were in the range 0.04-2.21 μM. Metabolites in rat urine could also be analysed in a reproducible way with retention time and peak area RSDs below 0.6% and 13.6%, respectively. The CE-MS and HILIC-MS methods were compared in terms of reproducibility, sensitivity, selectivity and coverage of the anionic urinary metabolome. In general, peak area RSDs were similar whereas HILIC-MS yielded better retention-time repeatability and up to 80 times lower detection limits (expressed in injected concentration) for test metabolites as compared to CE-MS. Rat urine analysis by HILIC-MS provided detection of 1360 molecular features compared to 347 molecular features revealed with CE-MS. Of these, a number of 144 molecular features were found with both HILIC-MS and CE-MS, which showed on average 10 times higher peak areas in HILIC-MS. The HILIC retention and CE migration times of the common features were clearly not correlated. The HILIC and CE behavior of the test metabolites and 16 putatively identified common features were evaluated involving their physicochemical properties, indicating a markedly different separation selectivity, and thus significant degree of orthogonality of HILIC and CE. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. The Development and Validation of the Client Expectations of Massage Scale

    PubMed Central

    Boulanger, Karen T.; Campo, Shelly; Glanville, Jennifer L.; Lowe, John B; Yang, Jingzhen

    2012-01-01

    Background: Although there is evidence that client expectations influence client outcomes, a valid and reliable scale for measuring the range of client expectations for both massage therapy and the behaviors of their massage therapists does not exist. Understanding how client expectations influence client outcomes would provide insight into how massage achieves its reported effects. Purpose: To develop and validate the Client Expectations of Massage Scale (CEMS), a measure of clients’ clinical, educational, interpersonal, and outcome expectations. Setting: Offices of licensed massage therapists in Iowa. Research Design: A practice-based research methodology was used to collect data from two samples of massage therapy clients. For Sample 1, 21 volunteer massage therapists collected data from their clients before the massage. Factor analysis was conducted to test construct validity and coefficient alpha was used to assess reliability. Correlational analyses with the CEMS, previous measures of client expectations, and the Life Orientation Test–Revised were examined to test the convergent and discriminant validity of the CEMS. For Sample 2, 24 massage therapists distributed study materials for clients to complete before and after a massage therapy session. Structural equation modeling was used to assess the construct, discriminant, and predictive validity of the CEMS. Participants: Sample 1 involved 320 and Sample 2 involved 321 adult massage clients. Intervention: Standard care provided by licensed massage therapists. Main Outcomes: Numeric Rating Scale for pain and Positive and Negative Affect Schedule–Revised (including the Serenity subscale). Results: The CEMS demonstrated good construct, convergent, discriminant and predictive validity, and adequate reliability. Client expectations were generally positive toward massage and their massage therapists. Positive outcome expectations had a positive effect on clients’ changes in pain and serenity. High interpersonal expectations had a negative effect on clients’ changes in serenity. Conclusions: Client expectations contribute to the nonspecific effects of massage therapy. PMID:23087774

  8. An Object-Oriented Approach to Writing Computational Electromagnetics Codes

    NASA Technical Reports Server (NTRS)

    Zimmerman, Martin; Mallasch, Paul G.

    1996-01-01

    Presently, most computer software development in the Computational Electromagnetics (CEM) community employs the structured programming paradigm, particularly using the Fortran language. Other segments of the software community began switching to an Object-Oriented Programming (OOP) paradigm in recent years to help ease design and development of highly complex codes. This paper examines design of a time-domain numerical analysis CEM code using the OOP paradigm, comparing OOP code and structured programming code in terms of software maintenance, portability, flexibility, and speed.

  9. Monitoring rFVIIa 90 μg kg⁻¹ dosing in haemophiliacs: comparing laboratory response using various whole blood assays over 6 h.

    PubMed

    Brophy, D F; Martin, E J; Christian Barrett, J; Nolte, M E; Kuhn, J G; Gerk, P M; Carr, M E; Pelzer, H; Agersø, H; Ezban, M; Hedner, U

    2011-09-01

    Recombinant FVIIa is a haemostatic agent administered to patients with severe FVIII or FIX deficiency with inhibitors. Although rFVIIa is effective at stopping bleeding, a reliable assay to monitor its effect is lacking. To characterize the pharmacokinetics and global coagulation effects of rFVIIa for 6 h following a IV dose of 90 μg kg⁻¹. Ten non-bleeding subjects with severe FVIII or FIX deficiency were infused with a single-dose of rFVIIa 90 μg k⁻¹ body weight and blood was collected before and at 0.5, 1, 2, 4 and 6 h postdose. Global haemostasis was characterized throughout the study utilizing whole blood analyses (Hemodyne HAS, TEG, ROTEM). The clearance and half-life of factor FVII:C was estimated as 39.0 ± 8.8 mL h⁻¹ kg⁻¹ and 2.1 ± 0.2 h respectively. There was good inter-assay agreement with respect to clot initiation parameters (R, CT and FOT) and these parameters all fell to a mean of approximately 9 min following rFVIIa dosing. The platelet contractile force (PCF) and clot elastic modulus (CEM) were positively correlated to FVII:C (P < 0.0001), and these parameters were dynamic throughout the 6-h period. The MA and MCF did not correlate to FVII:C nor did they significantly change during the study. Prothrombin F1 + 2 significantly increased following rFVIIa dosing (P < 0.001), but remained steady throughout the study. There was no change in D-dimer concentrations over time. The FOT, R and CT characterized clot initiation following rFVIIa dosing. The PCF and CEM were correlated to FVII:C and characterized the dynamics of platelet function and clot strength over the rFVIIa dosing interval. The clinical significance of these findings needs additional study. © 2011 Blackwell Publishing Ltd.

  10. The impact of oil burning on kraft recovery furnace SO sub 2 emissions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Someshwar, A.V.; Pinkerton, J.E.; Caron, A.L.

    1991-04-01

    Auxiliary fossil fuel, either natural gas or fuel oil, is burned in kraft recovery furnaces during furnace startups and shutdowns, furnace upsets, and periods of substantially reduced rates of black liquor firing. The efficiency of sulfur capture and retention during normal operation of a kraft recovery furnace is inherently high. Consequently, not all the SO{sub 2} from occasional burning of sulfur-containing fuel oil in the furnace would be expected to end up in the stack gases. However, the extent to which such SO{sub 2} is captured by the alkali fume generation processes has not been well documented. In this paper,more » the authors examines the impact that burning oil in kraft recovery furnaces has on the SO{sub 2} emissions. The work included analyses of long-term SO{sub 2} data from a continuous emission monitoring system (CEMS) obtained for four furnaces that burned medium sulfur fuel oil as auxiliary fuel. It also included tests conducted on four furnaces in which varying amounts of oil were co-fired with black liquor.« less

  11. Correlated Encounter Model for Cooperative Aircraft in the National Airspace System; Version 2.0

    DTIC Science & Technology

    2018-05-08

    Lincoln Laboratory MASSACHUSETTS INSTITUTE OF TECHNOLOGY LEXINGTON, MASSACHUSETTS Project Report ATC-440 Correlated Encounter Model for...specifically authorized by the U.S. Government may violate any copyrights that exist in this work. Correlated Encounter Model for Cooperative Aircraft...2008 Correlated Encounter Model for Cooperative Aircraft (CEM) subsequently referred to as the Extended Correlated Encounter Model (ECEM). This model

  12. Patterns and determinants of pathways to reach comprehensive emergency obstetric and neonatal care (CEmONC) in South Sudan: qualitative diagrammatic pathway analysis.

    PubMed

    Elmusharaf, Khalifa; Byrne, Elaine; AbuAgla, Ayat; AbdelRahim, Amal; Manandhar, Mary; Sondorp, Egbert; O'Donovan, Diarmuid

    2017-08-29

    Maternity referral systems have been under-documented, under-researched, and under-theorised. Responsive emergency referral systems and appropriate transportation are cornerstones in the continuum of care and central to the complex health system. The pathways that women follow to reach Emergency Obstetric and Neonatal Care (EmONC) once a decision has been made to seek care have received relatively little attention. The aim of this research was to identify patterns and determinants of the pathways pregnant women follow from the onset of labour or complications until they reach an appropriate health facility. This study was conducted in Renk County in South Sudan between 2010 and 2012. Data was collected using Critical Incident Technique (CIT) and stakeholder interviews. CIT systematically identified pathways to healthcare during labour, and factors associated with an event of maternal mortality or near miss through a series of in-depth interviews with witnesses or those involved. Face-to-face stakeholder interviews were conducted with 28 purposively identified key informants. Diagrammatic pathway and thematic analysis were conducted using NVIVO 10 software. Once the decision is made to seek emergency obstetric care, the pregnant woman may face a series of complex steps before she reaches an appropriate health facility. Four pathway patterns to CEmONC were identified of which three were associated with high rates of maternal death: late referral, zigzagging referral, and multiple referrals. Women who bypassed nonfunctional Basic EmONC facilities and went directly to CEmONC facilities (the fourth pathway pattern) were most likely to survive. Overall, the competencies of the providers and the functionality of the first point of service determine the pathway to further care. Our findings indicate that outcomes are better where there is no facility available than when the woman accesses a non-functioning facility, and the absence of a healthcare provider is better than the presence of a non-competent provider. Visiting non-functioning or partially functioning healthcare facilities on the way to competent providers places the woman at greater risk of dying. Non-functioning facilities and non-competent providers are likely to contribute to the deaths of women.

  13. India and the 21st Century Power Partnership: Paving the Way to a Smarter, Cleaner, More Resilient System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2017-05-09

    The 21st Century Power Partnership (21CPP) aims to accelerate the global transformation of power systems. The Power Partnership is a multilateral effort of the Clean Energy Ministerial (CEM) and serves as a platform for public-private collaboration to advance integrated policy, regulatory, financial, and technical solutions for the large-scale deployment of renewable energy in combination with deep energy efficiency and smart grid solutions. This fact sheet details the 21CPP's work in India.

  14. Ion-beam mixing at Fe:metallic-glass (Fe67Co18B14Si1) interface: A conversion-electron Mössbauer spectroscopic study

    NASA Astrophysics Data System (ADS)

    Bhandarkar, Y. V.; Ghaisas, S. V.; Ogale, S. B.

    1988-07-01

    Ion-beam mixing at an Fe:metallic glass (Fe67Co18B14Si1) interface is studied by employing the technique of conversion electron Mössbauer spectroscopy (CEMS). A 230-Å-thick overlayer of iron (enriched to 33% in the concentration of 57Fe Mössbauer isotope) was deposited on the shiny surface of metallic glass and such composites were bombarded with 100-keV Kr+ ions at dose values in the range between 1×1015 and 2×1016 ions/cm2. The transformations in the local atomic arrangements across the interface were investigated by monitoring the changes in the hyperfine-interaction parameters. It is shown that mixing leads to significant changes in the composition, in the vicinity of the interface as a function of the ion dose. At low dose (1×1015 ions/cm2) the local atomic coordination is found to be rich in the transition-metal concentration, while at a higher dose (2×1016 ions/cm2) it is observed to be rich in the boron concentration. Interestingly, at an intermediate dose 1×1016 ions/cm2 the composite near the interface region partially crystallizes and this structural state is found to revert back to the amorphous state upon thermal annealing at 300 °C. The observations made on the basis of CEMS are well supported by x-ray diffraction measurements.

  15. Calcium-enriched mixture pulpotomy of a human permanent molar with irreversible pulpitis and condensing apical periodontitis

    PubMed Central

    Asgary, Saeed

    2011-01-01

    This case report describes a pulpotomy treatment of a permanent mature molar tooth with established irreversible pulpitis and condensing apical periodontitis, using calcium-enriched mixture (CEM) cement. Clinical examination revealed that the first right lower molar had a large carious lesion with history of spontaneous/lingering pain; radiographic examination showed condensing apical periodontitis. Pulpotomy was opted as the treatment; cervical pulpotomy was carried out. Following hemostasis, the radicular pulp stumps were covered with ~2-mm-thick layer of the prepared CEM cement; the tooth was restored with amalgam. Two-year follow-up showed that the treated tooth had been symptomless, and there were no clinical signs/symptoms of either inflammation or infection. Radiographically, the periradicular lesion was completely healed with reconstruction of bone structures to normal appearance; the root canals were not calcified. According to chemical, physical, and biological properties of the CEM cement, this novel biomaterial may be suitable for endodontic treatment. PMID:21691516

  16. Calcium-enriched mixture cement as artificial apical barrier: A case series

    PubMed Central

    Nosrat, Ali; Asgary, Saeed; Eghbal, Mohammad Jafar; Ghoddusi, Jamileh; Bayat-Movahed, Saeed

    2011-01-01

    In comparison to the conventional apexification using calcium hydroxide, artificial apical barrier technique is more valuable and less time consuming. This article describes successful use of calcium-enriched mixture (CEM) cement as an artificial apical barrier in open apices. In this study, 13 single-rooted teeth with necrotic pulps and open apices were treated non-surgically. After copious irrigation of the root canals with NaOCl 5.25% and gentle filing, based on need for interappointment dressing, treatments were followed by CEM cement (BioniqueDent, Tehran, Iran) apical plug insertion in the first or second appointment. All cases were then permanently restored. All subjects were followed until radiographic evidence of periradicular healing was seen (mean 14.5 months). Clinically, all cases were functional and asymptomatic and complete osseous healing was observed in all the teeth. Considering the biological properties of CEM cement, this new endodontic biomaterial might be appropriate to be used as artificial apical barrier in the open apex teeth. PMID:22144818

  17. Synapse-specific astrocyte gating of amygdala-related behavior.

    PubMed

    Martin-Fernandez, Mario; Jamison, Stephanie; Robin, Laurie M; Zhao, Zhe; Martin, Eduardo D; Aguilar, Juan; Benneyworth, Michael A; Marsicano, Giovanni; Araque, Alfonso

    2017-11-01

    The amygdala plays key roles in fear and anxiety. Studies of the amygdala have largely focused on neuronal function and connectivity. Astrocytes functionally interact with neurons, but their role in the amygdala remains largely unknown. We show that astrocytes in the medial subdivision of the central amygdala (CeM) determine the synaptic and behavioral outputs of amygdala circuits. To investigate the role of astrocytes in amygdala-related behavior and identify the underlying synaptic mechanisms, we used exogenous or endogenous signaling to selectively activate CeM astrocytes. Astrocytes depressed excitatory synapses from basolateral amygdala via A 1 adenosine receptor activation and enhanced inhibitory synapses from the lateral subdivision of the central amygdala via A 2A receptor activation. Furthermore, astrocytic activation decreased the firing rate of CeM neurons and reduced fear expression in a fear-conditioning paradigm. Therefore, we conclude that astrocyte activity determines fear responses by selectively regulating specific synapses, which indicates that animal behavior results from the coordinated activity of neurons and astrocytes.

  18. Comparison of electrokinetic soil remediation methods using one fixed anode and approaching anodes.

    PubMed

    Shen, Zhemin; Chen, Xuejun; Jia, Jinping; Qu, Liya; Wang, Wenhua

    2007-11-01

    During the cation exchange membrane (CEM) enhanced electrokinetic (EK) soil remediation, the nearer to the anode, the higher are the H+ concentrations and the redox potentials. As both low pH and high redox potential are helpful to speed-up Cd electro-migration, soils near the anode can be quickly remedied. Usually EK process is operated with one fixed anode (FA). A novel CEM enhanced EK method with approaching anodes (AAs) is proposed to accelerate electro-migration effect. Several mesh Ti/Ru anodes were inserted as AAs in the treated soil. They were switched in turn from the anode towards the cathode. Thus high H+ ions concentrations and high redox potentials quickly migrate to the cathode. Consequently, soil remediation is accelerated and nearly 44% of energy and 40% of time can be saved. The mechanism of Cd electro-migration behavior in soils during CEM enhanced EK is described as the elution in an electrokinetically driven chromatogram.

  19. Junction Potentials Bias Measurements of Ion Exchange Membrane Permselectivity.

    PubMed

    Kingsbury, Ryan S; Flotron, Sophie; Zhu, Shan; Call, Douglas F; Coronell, Orlando

    2018-04-17

    Ion exchange membranes (IEMs) are versatile materials relevant to a variety of water and waste treatment, energy production, and industrial separation processes. The defining characteristic of IEMs is their ability to selectively allow positive or negative ions to permeate, which is referred to as permselectivity. Measured values of permselectivity that equal unity (corresponding to a perfectly selective membrane) or exceed unity (theoretically impossible) have been reported for cation exchange membranes (CEMs). Such nonphysical results call into question our ability to correctly measure this crucial membrane property. Because weighing errors, temperature, and measurement uncertainty have been shown to not explain these anomalous permselectivity results, we hypothesized that a possible explanation are junction potentials that occur at the tips of reference electrodes. In this work, we tested this hypothesis by comparing permselectivity values obtained from bare Ag/AgCl wire electrodes (which have no junction) to values obtained from single-junction reference electrodes containing two different electrolytes. We show that permselectivity values obtained using reference electrodes with junctions were greater than unity for CEMs. In contrast, electrodes without junctions always produced permselectivities lower than unity. Electrodes with junctions also resulted in artificially low permselectivity values for AEMs compared to electrodes without junctions. Thus, we conclude that junctions in reference electrodes introduce two biases into results in the IEM literature: (i) permselectivity values larger than unity for CEMs and (ii) lower permselectivity values for AEMs compared to those for CEMs. These biases can be avoided by using electrodes without a junction.

  20. Blind ICA detection based on second-order cone programming for MC-CDMA systems

    NASA Astrophysics Data System (ADS)

    Jen, Chih-Wei; Jou, Shyh-Jye

    2014-12-01

    The multicarrier code division multiple access (MC-CDMA) technique has received considerable interest for its potential application to future wireless communication systems due to its high data rate. A common problem regarding the blind multiuser detectors used in MC-CDMA systems is that they are extremely sensitive to the complex channel environment. Besides, the perturbation of colored noise may negatively affect the performance of the system. In this paper, a new coherent detection method will be proposed, which utilizes the modified fast independent component analysis (FastICA) algorithm, based on approximate negentropy maximization that is subject to the second-order cone programming (SOCP) constraint. The aim of the proposed coherent detection is to provide robustness against small-to-medium channel estimation mismatch (CEM) that may arise from channel frequency response estimation error in the MC-CDMA system, which is modulated by downlink binary phase-shift keying (BPSK) under colored noise. Noncoherent demodulation schemes are preferable to coherent demodulation schemes, as the latter are difficult to implement over time-varying fading channels. Differential phase-shift keying (DPSK) is therefore the natural choice for an alternative modulation scheme. Furthermore, the new blind differential SOCP-based ICA (SOCP-ICA) detection without channel estimation and compensation will be proposed to combat Doppler spread caused by time-varying fading channels in the DPSK-modulated MC-CDMA system under colored noise. In this paper, numerical simulations are used to illustrate the robustness of the proposed blind coherent SOCP-ICA detector against small-to-medium CEM and to emphasize the advantage of the blind differential SOCP-ICA detector in overcoming Doppler spread.

  1. Performance of Different Light Sources for the Absolute Calibration of Radiation Thermometers

    NASA Astrophysics Data System (ADS)

    Martín, M. J.; Mantilla, J. M.; del Campo, D.; Hernanz, M. L.; Pons, A.; Campos, J.

    2017-09-01

    The evolving mise en pratique for the definition of the kelvin (MeP-K) [1, 2] will, in its forthcoming edition, encourage the realization and dissemination of the thermodynamic temperature either directly (primary thermometry) or indirectly (relative primary thermometry) via fixed points with assigned reference thermodynamic temperatures. In the last years, the Centro Español de Metrología (CEM), in collaboration with the Instituto de Óptica of Consejo Superior de Investigaciones Científicas (IO-CSIC), has developed several setups for absolute calibration of standard radiation thermometers using the radiance method to allow CEM the direct dissemination of the thermodynamic temperature and the assignment of the thermodynamic temperatures to several fixed points. Different calibration facilities based on a monochromator and/or a laser and an integrating sphere have been developed to calibrate CEM's standard radiation thermometers (KE-LP2 and KE-LP4) and filter radiometer (FIRA2). This system is based on the one described in [3] placed in IO-CSIC. Different light sources have been tried and tested for measuring absolute spectral radiance responsivity: a Xe-Hg 500 W lamp, a supercontinuum laser NKT SuperK-EXR20 and a diode laser emitting at 6473 nm with a typical maximum power of 120 mW. Their advantages and disadvantages have been studied such as sensitivity to interferences generated by the laser inside the filter, flux stability generated by the radiant sources and so forth. This paper describes the setups used, the uncertainty budgets and the results obtained for the absolute temperatures of Cu, Co-C, Pt-C and Re-C fixed points, measured with the three thermometers with central wavelengths around 650 nm.

  2. Technical aspects and inter-laboratory variability in native peptide profiling: the CE-MS experience.

    PubMed

    Mischak, Harald; Vlahou, Antonia; Ioannidis, John P A

    2013-04-01

    Mass spectrometry platforms have attracted a lot of interest in the last 2 decades as profiling tools for native peptides and proteins with clinical potential. However, limitations associated with reproducibility and analytical robustness, especially pronounced with the initial SELDI systems, hindered the application of such platforms in biomarker qualification and clinical implementation. The scope of this article is to give a short overview on data available on performance and on analytical robustness of the different platforms for peptide profiling. Using the CE-MS platform as a paradigm, data on analytical performance are described including reproducibility (short-term and intermediate repeatability), stability, interference, quantification capabilities (limits of detection), and inter-laboratory variability. We discuss these issues by using as an example our experience with the development of a 273-peptide marker for chronic kidney disease. Finally, we discuss pros and cons and means for improvement and emphasize the need to test in terms of comparative clinical performance and impact, different platforms that pass reasonably well analytical validation tests. Copyright © 2012 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  3. Interface spins in polycrystalline FeMn/Fe bilayers with small exchange bias

    NASA Astrophysics Data System (ADS)

    Pires, M. J. M.

    2018-04-01

    The magnetic moments at the interface between ferromagnetic and antiferromagnetic layers play a central role in exchange biased systems, but their behavior is still not completely understood. In this work, the FeMn/Fe interface in polycrystalline thin films has been studied using conversion electron Mössbauer spectroscopy (CEMS), magneto-optic Kerr effect (MOKE) and micromagnetic simulations. Samples were prepared with 57Fe layers at two distinct depths in order to probe the interface and bulk behaviors. At the equilibrium, the interface moments are randomly oriented while the bulk of the Fe layer has an in-plane magnetic anisotropy. Several models for the interface and anisotropies of the layers were used in the simulations of spin configurations and hysteresis loops. From the whole set of simulations, one can conclude the direct analysis of hysteresis curves is not enough to infer whether the interface has a configuration with spins tilted out of the film plane at equilibrium since different choices of parameters provide similar curves. The simulations have also shown the occurrence of spin clusters at the interface is compatible with CEMS and MOKE measurements.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kerby, Leslie Marie

    Emission of light fragments (LF) from nuclear reactions is an open question. Different reaction mechanisms contribute to their production; the relative roles of each, and how they change with incident energy, mass number of the target, and the type and emission energy of the fragments is not completely understood. None of the available models are able to accurately predict emission of LF from arbitrary reactions. However, the ability to describe production of LF (especially at energies ≳ 30 MeV) from many reactions is important for different applications, such as cosmic-ray-induced Single Event Upsets (SEUs), radiation protection, and cancer therapy withmore » proton and heavy-ion beams, to name just a few. The Cascade-Exciton Model (CEM) version 03.03 and the Los Alamos version of the Quark-Gluon String Model (LAQGSM) version 03.03 event generators in Monte Carlo N-Particle Transport Code version 6 (MCNP6) describe quite well the spectra of fragments with sizes up to ⁴He across a broad range of target masses and incident energies (up to ~ 5 GeV for CEM and up to ~ 1 TeV/A for LAQGSM). However, they do not predict the high energy tails of LF spectra heavier than ⁴He well. Most LF with energies above several tens of MeV are emitted during the precompound stage of a reaction. The current versions of the CEM and LAQGSM event generators do not account for precompound emission of LF larger than ⁴He. The aim of our work is to extend the precompound model in them to include such processes, leading to an increase of predictive power of LF-production in MCNP6. This entails upgrading the Modified Exciton Model currently used at the preequilibrium stage in CEM and LAQGSM. It also includes expansion and examination of the coalescence and Fermi break-up models used in the precompound stages of spallation reactions within CEM and LAQGSM. Extending our models to include emission of fragments heavier than ⁴He at the precompound stage has indeed provided results that have much better agreement with experimental data.« less

  5. The sedimentological changes caused by human impact at the artificial channel of Medjerda-River (Coastal zone of Medjerda, Tunisia)

    NASA Astrophysics Data System (ADS)

    Benmoussa, Thouraya; Amrouni, Oula; Dezileau, Laurent; Mahé, Gil; Abdeljaouad, Saâdi

    2018-04-01

    Recent sedimentary and morphological changes at the new mouth of Medjerda-River (Gulf of Tunis) are investigated using a multiproxy approach of sediment cores complited by 210Pbex and 137Cs method dating. The subject of the study is to focus on surveying the sedimentary evolution of Medjerda-Raoued Delta caused by the human intervention in the management of the main tributaries of the Medjerda-River (artificial channel of Henchir Tobias). Sediment cores (CEM-1 and CEM-3) were subjected to both multiproxy approaches (Grain size, geochemical analysis and dating radiometric 210Pbex and 137Cs). The sedimentological analysis of the new deltaic deposits shows a progradation sequence with the silt and clay deposits on the historic sandy substratum. The mean grain size evolution on the old beach profile shows a decreasing trend from backshore (CEM-3) to nearshore (CEM-1). The geochemical results show varying concentrations of chemical elements such as Fe, K, Rb, Nb, Cr, Ti, Ba, Ca, Sr, Zr, V, and potentially toxic metal trace elements such as Pb, Zn and the As. The Principal component Analysis (PCA) applied in the geochemical elements evolution confirms the marine origin of the sand deposits in the basic layers of the two cores. The chronological method (210Pbex and 137Cs) affirms that the first fluvial deposits were set up only after 1950. The sedimentological and geochemical result confirm the actual unless of coarser fluvial supplies under the human activities leading the negative coastal sediment balance and the shoreline retreat as well.

  6. ROMANCE: A new software tool to improve data robustness and feature identification in CE-MS metabolomics.

    PubMed

    González-Ruiz, Víctor; Gagnebin, Yoric; Drouin, Nicolas; Codesido, Santiago; Rudaz, Serge; Schappler, Julie

    2018-05-01

    The use of capillary electrophoresis coupled to mass spectrometry (CE-MS) in metabolomics remains an oddity compared to the widely adopted use of liquid chromatography. This technique is traditionally regarded as lacking the reproducibility to adequately identify metabolites by their migration times. The major reason is the variability of the velocity of the background electrolyte, mainly coming from shifts in the magnitude of the electroosmotic flow and from the suction caused by electrospray interfaces. The use of the effective electrophoretic mobility is one solution to overcome this issue as it is a characteristic feature of each compound. To date, such an approach has not been applied to metabolomics due to the complexity and size of CE-MS data obtained in such studies. In this paper, ROMANCE (RObust Metabolomic Analysis with Normalized CE) is introduced as a new software for CE-MS-based metabolomics. It allows the automated conversion of batches of CE-MS files with minimal user intervention. ROMANCE converts the x-axis of each MS file from the time into the effective mobility scale and the resulting files are already pseudo-aligned, present normalized peak areas and improved reproducibility, and can eventually follow existing metabolomic workflows. The software was developed in Scala, so it is multi-platform and computationally-efficient. It is available for download under a CC license. In this work, the versatility of ROMANCE was demonstrated by using data obtained in the same and in different laboratories, as well as its application to the analysis of human plasma samples. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. The enzymatic activity of CEM15/Apobec-3G is essential for the regulation of the infectivity of HIV-1 virion but not a sole determinant of its antiviral activity.

    PubMed

    Shindo, Keisuke; Takaori-Kondo, Akifumi; Kobayashi, Masayuki; Abudu, Aierken; Fukunaga, Keiko; Uchiyama, Takashi

    2003-11-07

    Human immunodeficiency virus, type 1 (HIV-1) Vif protein plays an essential role in the regulation of the infectivity of HIV-1 virion. Vif functions to counteract an anti-HIV-1 cellular factor in non-permissive cells, CEM15/Apobec-3G, which shares a cytidine deaminase motif. CEM15/Apobec-3G deaminates dC to dU in the minus strand DNA of HIV-1, resulting in G to A hypermutation in the plus strand DNA. In this study, we have done the mutagenesis analysis on two cytidine deaminase motifs in CEM15/Apobec-3G and examined their antiviral functions as well as the DNA editing activity. Point mutations in the C-terminal active site such as E259Q and C291A almost completely abrogated the antiviral function, while those in the N-terminal active site such as E67Q and C100A retained this activity to a lesser extent as compared with that of the wild type. The DNA editing activities of E67Q and E259Q mutants were both retained but impaired to the same extent. This indicates that the enzymatic activity of this protein is essential but not a sole determinant of the antiviral activity. Furthermore, all the deletion mutants tested in this study lost the antiviral activity because of the loss of the activity for dimerization, suggesting that the entire protein structure is necessary for the antiviral function.

  8. Phytochemical analysis and cytotoxicity towards multidrug-resistant leukemia cells of essential oils derived from Lebanese medicinal plants.

    PubMed

    Saab, Antoine M; Guerrini, Alessandra; Sacchetti, Gianni; Maietti, Silvia; Zeino, Maʼen; Arend, Joachim; Gambari, Roberto; Bernardi, Francesco; Efferth, Thomas

    2012-12-01

    Juniperus excelsa fruit essential oil as well as J. oxycedrus, Cedrus libani, and Pinus pinea wood essential oils have been obtained with yields between 2.2 ± 0.3 % to 3.4 ± 0.5 % and analyzed by gas chromatography. Sesquiterpenes mainly characterized C. libani and J. oxycedrus essential oils, while in P. pinea and J. excelsa, monoterpenes were the most abundant compounds. In J. oxycedrus, cis-calamenene (7.8 %), cuparene (3.8 %), and cis-thujopsenal (2.0 %) have been detected for the first time. The cytotoxic activity of these essential oils against drug-sensitive CCRF-CEM and multidrug-resistant P-glycoprotein-expressing CEM/ADR5000 leukemia cells has been investigated (IC₅₀ values: 29.46 to 61.54 µg/mL). Remarkably, multidrug-resistant CEM/ADR5000 cells did not reveal cross-resistance, indicating that these essential oils might be useful to treat otherwise drug-resistant and refractory tumors. Georg Thieme Verlag KG Stuttgart · New York.

  9. Miniature Pulpotomy of Symptomatic Mature Permanent Teeth: A Report of Two Cases.

    PubMed

    Asgary, Saeed; Nourzadeh, Mahdieh; Eghbal, Mohammad Jafar

    2016-01-01

    Human dental pulp inflammation can progress to periapical lesion formation and conventional root canal treatment (RCT) has been the traditional method for disease management. This observational study presents two cases of vital pulp therapy in mature molars diagnosed with irreversible pulpitis and associated with apical periodontitis. In these two clinical cases, the involved teeth had deep carious lesions with a history of spontaneous/lingering pain and radiographic examinations revealed the presence of apical radiolucencies. A conservative miniature pulpotomy (MP) using calcium-enriched mixture (CEM) was performed and the teeth were permanently restored with amalgam. Clinical evaluations indicated resolution of pain 24 hours after treatment; the teeth showed normal vitality, remained asymptomatic and maintained normal function after recall examinations. Furthermore, the 18-month radiographic evaluation showed healing of the apical lesions. Vital pulp therapy using the MP technique with CEM appeared successful in avoiding RCT intervention. These two reports of case outcome suggest that simple MP using a CEM bioregenerative technique may provide a favorable outcome for permanent teeth diagnosed with irreversible pulpitis and associated with apical periodontitis.

  10. Two-photon absorption in conjugated energetic molecule

    DOE PAGES

    Bjorgaard, Josiah August; Sifain, Andrew; Nelson, Tammie Renee; ...

    2016-06-03

    Time-dependent density functional theory (TD-DFT) is used to investigate the relationship between molecular structure and one- and two-photon absorption (OPA and TPA, respectively) properties in novel and recently synthesized conjugated energetic molecules (CEMs). The molecular structure of CEMs can be strategically altered to influence the heat of formation and oxygen balance, two factors that can contribute to the sensitivity and strength of an explosive material. OPA and TPA are sensitive to changes in molecular structure as well, influencing optical range of excitation. We find calculated vertical excitation energies in good agreement with experiment for most molecules. Peak TPA intensities aremore » significant and on the order of 102 GM. Natural transition orbitals for essential electronic states defining TPA peaks of relatively large intensity to examine the character of relevant transitions. Minor modification of molecular substituents, such as additional oxygen and other functional groups, produces significant changes in electronic structure, OPA, TPA, and improves the oxygen balance. Results show that select molecules are apt to nonlinear absorption, opening the possibility for controlled, direct optical initiation of CEMs through photochemical pathways.« less

  11. Evaluation of hydrogen production and internal resistance in forward osmosis membrane integrated microbial electrolysis cells.

    PubMed

    Lee, Mi-Young; Kim, Kyoung-Yeol; Yang, Euntae; Kim, In S

    2015-01-01

    In order to enhance hydrogen production by facilitated proton transport through a forward osmosis (FO) membrane, the FO membrane was integrated into microbial electrolysis cells (MECs). An improved hydrogen production rate was obtained in the FO-MEC (12.5±1.84×10(-3)m(3)H2/m(3)/d) compared to that of the cation exchange membrane (CEM) - MEC (4.42±0.04×10(-3)m(3)H2/m(3)/d) during batch tests (72h). After an internal resistance analysis, it was confirmed that the enhanced hydrogen production in FO-MEC was attributed to the smaller charge transfer resistance than in the CEM-MEC (90.3Ω and 133.4Ω respectively). The calculation of partial internal resistance concluded that the transport resistance can be substantially reduced by replacing a CEM with a FO membrane; decrease of the resistance from 0.069Ωm(2) to 5.99×10(-4)Ωm(2). Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. HIV-1 Vpr increases Env expression by preventing Env from endoplasmic reticulum-associated protein degradation (ERAD).

    PubMed

    Zhang, Xianfeng; Zhou, Tao; Frabutt, Dylan A; Zheng, Yong-Hui

    2016-09-01

    Vpr enhances HIV-1 replication in macrophages and dendritic cells, as well as the human CD4(+) CEM.NKR T cell line. Recently, Vpr was reported to increase HIV-1 Env expression in macrophages. Here, we report that Vpr also increases HIV-1 Env expression in dendritic cells and CEM.NKR cells. The Vpr activity depends on its N-terminal region, which was disrupted by a single A30L mutation. Env was rapidly degraded in the absence of Vpr, which was blocked by the ERAD pathway inhibitor kifunesine or the lysosome inhibitor Bafilomycin. As2O3 or PK11195, which reportedly enhances HIV-1 Env folding, also blocked the Env degradation in CEM.NKR cells. Thus, these results not only identify Env as a primary target for Vpr to boost HIV-1 replication, but also suggest that Vpr likely promotes Env folding in the ER, which is otherwise misfolded and targeted by the ERAD pathway to lysosomes for degradation. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Vibration attenuation of the NASA Langley evolutionary structure experiment using H(sub infinity) and structured singular value (micron) robust multivariable control techniques

    NASA Technical Reports Server (NTRS)

    Balas, Gary J.

    1992-01-01

    The use is studied of active control to attenuate structural vibrations of the NASA Langley Phase Zero Evolutionary Structure due to external disturbance excitations. H sub infinity and structured singular value (mu) based control techniques are used to analyze and synthesize control laws for the NASA Langley Controls Structures Interaction (CSI) Evolutionary Model (CEM). The CEM structure experiment provides an excellent test bed to address control design issues for large space structures. Specifically, control design for structures with numerous lightly damped, coupled flexible modes, collocated and noncollocated sensors and actuators and stringent performance specifications. The performance objectives are to attenuate the vibration of the structure due to external disturbances, and minimize the actuator control force. The control design problem formulation for the CEM Structure uses a mathematical model developed with finite element techniques. A reduced order state space model for the control design is formulated from the finite element model. It is noted that there are significant variations between the design model and the experimentally derived transfer function data.

  14. Acid Rain Data System: Progressive application of information technology for operation of a market-based environmental program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Price, D.A.

    1995-12-31

    Under the Acid Rain Program, by statute and regulation, affected utility units are allocated annual allowances. Each allowance permits a unit to emit one ton of SO{sub 2} during or after a specified year. At year end, utilities must hold allowances equal to or greater than the cumulative SO{sub 2} emissions throughout the year from their affected units. The program has been developing, on a staged basis, two major computer-based information systems: the Allowance Tracking System (ATS) for tracking creation, transfer, and ultimate use of allowances; and the Emissions Tracking System (ETS) for transmission, receipt, processing, and inventory of continuousmore » emissions monitoring (CEM) data. The systems collectively form a logical Acid Rain Data System (ARDS). ARDS will be the largest information system ever used to operate and evaluate an environmental program. The paper describes the progressive software engineering approach the Acid Rain Program has been using to develop ARDS. Iterative software version releases, keyed to critical program deadlines, add the functionality required to support specific statutory and regulatory provisions. Each software release also incorporates continual improvements for efficiency, user-friendliness, and lower life-cycle costs. The program is migrating the independent ATS and ETS systems into a logically coordinated True-Up processing model, to support the end-of-year reconciliation for balancing allowance holdings against annual emissions and compliance plans for Phase 1 affected utility units. The paper provides specific examples and data to illustrate exciting applications of today`s information technology in ARDS.« less

  15. CSI computer system/remote interface unit acceptance test results

    NASA Technical Reports Server (NTRS)

    Sparks, Dean W., Jr.

    1992-01-01

    The validation tests conducted on the Control/Structures Interaction (CSI) Computer System (CCS)/Remote Interface Unit (RIU) is discussed. The CCS/RIU consists of a commercially available, Langley Research Center (LaRC) programmed, space flight qualified computer and a flight data acquisition and filtering computer, developed at LaRC. The tests were performed in the Space Structures Research Laboratory (SSRL) and included open loop excitation, closed loop control, safing, RIU digital filtering, and RIU stand alone testing with the CSI Evolutionary Model (CEM) Phase-0 testbed. The test results indicated that the CCS/RIU system is comparable to ground based systems in performing real-time control-structure experiments.

  16. Air pollution response to changing weather and power plant emissions in the eastern United States

    NASA Astrophysics Data System (ADS)

    Bloomer, Bryan Jaye

    Air pollution in the eastern United States causes human sickness and death as well as damage to crops and materials. NOX emission reduction is observed to improve air quality. Effectively reducing pollution in the future requires understanding the connections between smog, precursor emissions, weather, and climate change. Numerical models predict global warming will exacerbate smog over the next 50 years. My analysis of 21 years of CASTNET observations quantifies a climate change penalty. I calculate, for data collected prior to 2002, a climate penalty factor of ˜3.3 ppb O3/°C across the power plant dominated receptor regions in the rural, eastern U.S. Recent reductions in NOX emissions decreased the climate penalty factor to ˜2.2 ppb O3/°C. Prior to 1995, power plant emissions of CO2, SO2, and NOX were estimated with fuel sampling and analysis methods. Currently, emissions are measured with continuous monitoring equipment (CEMS) installed directly in stacks. My comparison of the two methods show CO 2 and SO2 emissions are ˜5% lower when inferred from fuel sampling; greater differences are found for NOX emissions. CEMS are the method of choice for emission inventories and commodity trading and should be the standard against which other methods are evaluated for global greenhouse gas trading policies. I used CEMS data and applied chemistry transport modeling to evaluate improvements in air quality observed by aircraft during the North American electrical blackout of 2003. An air quality model produced substantial reductions in O3, but not as much as observed. The study highlights weaknesses in the model as commonly used for evaluating a single day event and suggests areas for further investigation. A new analysis and visualization method quantifies local-daily to hemispheric-seasonal scale relationships between weather and air pollution, confirming improved air quality despite increasing temperatures across the eastern U.S. Climate penalty factors indicate amplified smog formation in areas of the world with rising temperatures and increasing emissions. Tools developed in this dissertation provide data for model evaluation and methods for establishing air quality standards with an adequate margin of safety for cleaning the air and protecting the public's health in a world with changing climate.

  17. Sample treatments prior to capillary electrophoresis-mass spectrometry.

    PubMed

    Hernández-Borges, Javier; Borges-Miquel, Teresa M; Rodríguez-Delgado, Miguel Angel; Cifuentes, Alejandro

    2007-06-15

    Sample preparation is a crucial part of chemical analysis and in most cases can become the bottleneck of the whole analytical process. Its adequacy is a key factor in determining the success of the analysis and, therefore, careful selection and optimization of the parameters controlling sample treatment should be carried out. This work revises the different strategies that have been developed for sample preparation prior to capillary electrophoresis-mass spectrometry (CE-MS). Namely the present work presents an exhaustive and critical revision of the different samples treatments used together with on-line CE-MS including works published from January 2000 to July 2006.

  18. Interfacial chemical reactions between MoS2 lubricants and bearing materials

    NASA Technical Reports Server (NTRS)

    Zabinski, J. S.; Tatarchuk, B. J.

    1989-01-01

    XPS and conversion-electron Moessbauer spectroscopy (CEMS) were used to examine iron that was deposited on the basal plane of MoS2 single crystals and subjected to vacuum annealing, oxidizing, and reducing environments. Iron either intercalated into the MoS2 structure or formed oriented iron sulfides, depending on the level of excess S in the MoS2 structure. CEMS data demonstrated that iron sulfide crystal structures preferentially aligned with respect to the MoS2 basal plane, and that alignment (and potentially adhesion) could be varied by appropriate high-temperature annealing procedures.

  19. Energy-Efficient Ammonia Recovery in an Up-Scaled Hydrogen Gas Recycling Electrochemical System

    PubMed Central

    2018-01-01

    Nutrient and energy recovery is becoming more important for a sustainable future. Recently, we developed a hydrogen gas recycling electrochemical system (HRES) which combines a cation exchange membrane (CEM) and a gas-permeable hydrophobic membrane for ammonia recovery. This allowed for energy-efficient ammonia recovery, since hydrogen gas produced at the cathode was oxidized at the anode. Here, we successfully up-scaled and optimized this HRES for ammonia recovery. The electrode surface area was increased to 0.04 m2 to treat up to 11.5 L/day (∼46 gN/day) of synthetic urine. The system was operated stably for 108 days at current densities of 20, 50, and 100 A/m2. Compared to our previous prototype, this new cell design reduced the anode overpotential and ionic losses, while the use of an additional membrane reduced the ion transport losses. Overall, this reduced the required energy input from 56.3 kJ/gN (15.6 kW h/kgN) at 50 A/m2 (prototype) to 23.4 kJ/gN (6.5 kW h/kgN) at 100 A/m2 (this work). At 100 A/m2, an average recovery of 58% and a TAN (total ammonia nitrogen) removal rate of 598 gN/(m2 day) were obtained across the CEM. The TAN recovery was limited by TAN transport from the feed to concentrate compartment. PMID:29888142

  20. Comparison of shear bond strength of self-etch and self-adhesive cements bonded to lithium disilicate, enamel and dentin.

    PubMed

    Naranjo, Jennifer; Ali, Mohsin; Belles, Donald

    2015-11-01

    Comparison of shear bond strength of self-etch and self-adhesive cements bonded to lithium disilicate, enamel and dentin. With several self-adhesive resin cements currently available, there is confusion about which product and technique is optimal for bonding ceramic restorations to teeth. The objective of this study was to compare the shear bond strength of lithium disilicate cemented to enamel and dentin using 5 adhesive cements. 100 lithium disilicate rods were pretreated with 5% hydrofluoric acid, silane, and cemented to 50 enamel and 50 dentin surfaces using five test cements: Variolink II (etch-and-rinse) control group, Clearfil Esthetic (two step self-etch), RelyX Unicem, SpeedCEM, and BifixSE (self-adhesive). All specimens were stored (37 degrees C, 100% humidity) for 24 hours before testing their shear bond strength using a universal testing machine (Instron). Debonded surfaces were observed under a low-power microscope to assess the location and type of failure. The highest bond strength for both enamel and dentin were recorded for Variolink II, 15.1MPa and 20.4MPa respectively, and the lowest were recorded for BifixSE, 0.6MPa and 0.9MPa respectively. Generally, higher bond strengths were found for dentin (7.4MPa) than enamel (5.3MPa). Tukey's post hoc test showed no significant difference between Clearfil Esthetic and SpeedCem (p = 0.059), Unicem and SpeedCem (p = 0.88), and Unicem and BifixSE (p = 0.092). All cements bonded better to lithium disilicate than to enamel or dentin, as all bond failures occurred at the tooth/adhesive interface except for Variolink II. Bond strengths recorded for self-adhesive cements were very low compared to the control "etch and rinse" and self-etch systems. Further improvements are apparently needed in self-adhesive cements for them to replace multistep adhesive systems. The use of conventional etch and rinse cements such as Veriolink II should be preferred for cementing all ceramic restorations over self-adhesive cements until the bond strengths are improved.

  1. Measurement and simulation of the cross sections for nuclide production in {sup nat}W and {sup 181}Ta targets irradiated with 0.04- to 2.6-GeV protons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Titarenko, Yu. E., E-mail: Yury.Titarenko@itep.ru; Batyaev, V. F.; Titarenko, A. Yu.

    The cross sections for nuclide production in thin {sup nat}Wand {sup 181}Ta targets irradiated by 0.04-2.6-GeV protons have been measured by direct {gamma} spectrometry using two {gamma} spectrometers with the resolutions of 1.8 and 1.7 keV in the {sup 60}Co 1332-keV {gamma} line. As a result, 1895 yields of radioactive residual product nuclei have been obtained. The {sup 27}Al(p, x){sup 22}Na reaction has been used as a monitor reaction. The experimental data have been compared with the MCNPX (BERTINI, ISABEL), CEM03.02, INCL4.2, INCL4.5, PHITS, and CASCADE07 calculations.

  2. Measurement and simulation of the cross sections for nuclide production in {sup 93}Nb and {sup nat}Ni targets irradiated with 0.04- to 2.6-GeV protons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Titarenko, Yu. E., E-mail: Yury.Titarenko@itep.ru; Batyaev, V. F.; Titarenko, A. Yu.

    The cross sections for nuclide production in thin {sup 93}Nb and {sup nat}Ni targets irradiated by 0.04- to 2.6-GeV protons have been measured by direct {gamma} spectrometry using two {gamma} spectrometers with the resolutions of 1.8 and 1.7 keV in the {sup 60}Co 1332-keV {gamma} line. As a result, 1112 yields of radioactive residual nuclei have been obtained. The {sup 27}Al(p, x){sup 22}Na reaction has been used as a monitor reaction. The experimental data have been compared with the MCNPX (BERTINI, ISABEL), CEM03.02, INCL4.2, INCL4.5, PHITS, and CASCADE07 calculations.

  3. Measurement and simulation of the cross sections for nuclide production in {sup 56}Fe and {sup nat}Cr targets irradiated with 0.04- to 2.6-GeV protons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Titarenko, Yu. E., E-mail: Yury.Titarenko@itep.ru; Batyaev, V. F.; Titarenko, A. Yu.

    The cross sections for nuclide production in thin {sup 56}Fe and {sup nat}Cr targets irradiated by 0.04-2.6-GeV protons are measured by direct {gamma} spectrometry using two {gamma} spectrometers with the resolutions of 1.8 and 1.7 keV for the {sup 60}Co 1332-keV {gamma} line. As a result, 649 yields of radioactive residual product nuclei have been obtained. The {sup 27}Al(p, x){sup 22}Na reaction has been used as a monitor reaction. The experimental data are compared with the MCNPX (BERTINI, ISABEL), CEM03.02, INCL4.2, INCL4.5, PHITS, and CASCADE07 calculations.

  4. Capillary electrophoresis/mass spectrometry determination of inorganic ions using an ion spray-sheath flow interface.

    PubMed

    Huggins, T G; Henion, J D

    1993-01-01

    The determination of inorganic cations and anions by capillary electrophoresis/mass spectrometry (CE/MS) is reported using an ion spray-sheath flow interface coupling. A twelve-component synthetic mixture of cations which included the positive ions of K, Ba, Ca, Mn, Cd, Co, Pb, Cr, Ni, Zn, Ag, and Cu was loaded into the capillary column at levels ranging from 30 to 300 pg, separated by CE, and detected by indirect UV and in the full-scan (m/z 35-450) positive ion CE/MS mode using an aqueous buffer containing 30 mM creatinine and 8 mM alpha-hydroxyisobutyric acid, pH 4.8. Creatinine forms adducts with the cations which are observed in the gas phase and requires rather high (120 electron volts) declustering energy to dissociate. This produces a reduction in charge state to form the free, singly charged, inorganic cations which are observed in the mass spectra. CE/MS analysis of an aqueous acidic extract of used aircraft engine oil revealed high levels of lead as well as lower levels of chromium and nickel. CE-indirect UV analysis of a synthetic mixture containing 300 pg each of 11 inorganic ions, which included the anions of Br, Cl, NO2, NO3, S2O3, N3, SCN, SO4, SeO4, oxalate, and MoO4, is shown. The running buffer which affected this separation contained 5 mM ammonium dichromate, 10 mM ammonium acetate, and 20 mM diethylenetriamine at pH 9.3. Although indirect UV detection revealed good separation of these anions, CE/MS analysis of this mixture was complicated by interfering ion current signals from the cluster ions formed by the interaction between the additives and the analytes.(ABSTRACT TRUNCATED AT 250 WORDS)

  5. In Vitro Cytotoxicity and Setting Time Assessment of Calcium-Enriched Mixture Cement, Retro Mineral Trioxide Aggregate and Mineral Trioxide Aggregate

    PubMed Central

    Pornamazeh, Tahereh; Yadegari, Zahra; Ghasemi, Amir; Sheykh-al-Eslamian, Seyedeh Mahsa; Shojaeian, Shiva

    2017-01-01

    Introduction: The present study sought to evaluate and compare biocompatibility and setting time of Retro mineral trioxide aggregate (MTA), calcium-enriched mixture (CEM) and Angelus MTA. Methods and Materials: CEM cement, Angelus MTA and Retro MTA were assessed in set and fresh states. Extracts transformed to each cavity of three 24-well plates in which 1×104 cell were seeded into each well 24 h earlier. All specimens were incubated in a humidified incubator with 5% CO2 at 37°C. Mosmann’s tetrazolium toxicity (MTT) assay was used to determine in vitro cytotoxicity on L929 mouse fibroblast cell line. Cell viability was determined at 1, 24, and 72 h after exposure. The initial setting time was measured by 113.4 g Gilmore needle testing. Then, final setting times were assessed by the 456.5 g Gilmore needle. Data comparisons were performed using the analysis of variance (ANOVA) and Tukey's post hoc test (α=0.05). Results: All groups in both forms indicated higher cell vitality compared to positive control group (P<0.001). After 24 h, the set Retro MTA showed better biocompatibility compared to set CEM and set Angelus MTA (P<0.001). Retro MTA showed significantly lower initial and final setting time compared to CEM and Angelus MTA (P<0.001). Conclusion: Our results indicated the good cell viability values of Retro MTA and relatively short period of setting time. It seems a promising alternative material in clinical situations where accelerated setting is required. However, more clinical and in vivo investigations are needed for a clear decision making. PMID:29225646

  6. Phase evolution, characterisation, and performance of cement prepared in an oxy-fuel atmosphere.

    PubMed

    Zheng, Liya; Hills, Thomas P; Fennell, Paul

    2016-10-20

    Cement manufacture is one of the major contributors (7-10%) to global anthropogenic CO 2 emissions. Carbon capture and storage (CCS) has been identified as a vital technology for decarbonising the sector. Oxy-fuel combustion, involving burning fuel in a mixture of recycled CO 2 and pure O 2 instead of air, makes CO 2 capture much easier. Since it combines a theoretically lower energy penalty with an increase in production, it is attractive as a CCS technology in cement plants. However, it is necessary to demonstrate that changes in the clinkering atmosphere do not reduce the quality of the clinker produced. Clinkers were successfully produced in an oxy-fuel atmosphere using only pure oxides as raw materials as well as a mixture of oxides and clay. Then, CEM I cements were prepared by the addition of 5 wt% gypsum to the clinkers. Quantitative XRD and XRF were used to obtain the phase and elemental compositions of the clinkers. The particle size distribution and compressive strength of the cements at 3, 7, 14, and 28 days' ages were tested, and the effect of the particle size distribution on the compressive strength was investigated. Additionally, the compressive strength of the cements produced in oxy-fuel atmospheres was compared with those of the cement produced in air and commercially available CEMEX CEM I. The results show that good-quality cement can be successfully produced in an oxy-fuel atmosphere and it has similar phase and chemical compositions to CEM I. Additionally, it has a comparable compressive strength to the cement produced in air and to commercially available CEMEX CEM I.

  7. CLIC, a tool for expanding biological pathways based on co-expression across thousands of datasets

    PubMed Central

    Li, Yang; Liu, Jun S.; Mootha, Vamsi K.

    2017-01-01

    In recent years, there has been a huge rise in the number of publicly available transcriptional profiling datasets. These massive compendia comprise billions of measurements and provide a special opportunity to predict the function of unstudied genes based on co-expression to well-studied pathways. Such analyses can be very challenging, however, since biological pathways are modular and may exhibit co-expression only in specific contexts. To overcome these challenges we introduce CLIC, CLustering by Inferred Co-expression. CLIC accepts as input a pathway consisting of two or more genes. It then uses a Bayesian partition model to simultaneously partition the input gene set into coherent co-expressed modules (CEMs), while assigning the posterior probability for each dataset in support of each CEM. CLIC then expands each CEM by scanning the transcriptome for additional co-expressed genes, quantified by an integrated log-likelihood ratio (LLR) score weighted for each dataset. As a byproduct, CLIC automatically learns the conditions (datasets) within which a CEM is operative. We implemented CLIC using a compendium of 1774 mouse microarray datasets (28628 microarrays) or 1887 human microarray datasets (45158 microarrays). CLIC analysis reveals that of 910 canonical biological pathways, 30% consist of strongly co-expressed gene modules for which new members are predicted. For example, CLIC predicts a functional connection between protein C7orf55 (FMC1) and the mitochondrial ATP synthase complex that we have experimentally validated. CLIC is freely available at www.gene-clic.org. We anticipate that CLIC will be valuable both for revealing new components of biological pathways as well as the conditions in which they are active. PMID:28719601

  8. Cytotoxicity of compounds from Xylopia aethiopica towards multi-factorial drug-resistant cancer cells.

    PubMed

    Kuete, Victor; Sandjo, Louis P; Mbaveng, Armelle T; Zeino, Maen; Efferth, Thomas

    2015-12-15

    Multidrug resistance (MDR) in cancer represent a major hurdle in chemotherapy. Previously, the methanol extract of the medicinal spice Xylopia aethiopica displayed considerable cytotoxicity against multidrug resistant (MDR) cancer cell lines. The present study was designed to assess the cytotoxicity of compounds, 16α-hydroxy-ent-kauran-19-oic acid (2), 3,4',5-trihydroxy-6″,6″-dimethylpyrano[2,3-g]flavone (3), isotetrandrine (5) and trans-tiliroside (6) derived from the methanol crude extract of Xylopia aethiopica against 9 drug-sensitive and -resistant cancer cell lines. The resazurin reduction assay was used to evaluate the cytotoxicity of these compounds, whilst caspase-Glo assay was used to detect caspase activation. Cell cycle, mitochondrial membrane potential (MMP) and levels of reactive oxygen species (ROS) were all analyzed via flow cytometry. Flavonoid 3 and alkaloid 5 also displayed IC50 values ranging from 2.61 µM (towards leukemia CCRF-CEM cells) to 18.60 µM (towards gliobastoma multiforme U87MG.ΔEGFR cells) and from 1.45 µM (towards HepG2 cells) to 7.28 µM (towards MDA-MB-231-pcDNA cells), respectively. IC50 values ranged from 0.20 µM (against CCRF-CEM cells) to 195.12 µM (against CEM/ADR5000 cells) for doxorubicin. Compound 3 induced apoptosis in leukemia CCRF-CEM cells mediated by the disruption of the MMP, whilst 5 induced apoptosis mediated by ROS production. Compounds 2 and 5 represent potential cytotoxic phytochemicals that deserve more investigations to develop novel antineoplastic drugs against multifactorial drug-resistant cancers. Copyright © 2015 Elsevier GmbH. All rights reserved.

  9. Cytotoxic Activity of Extracts from Plants of Central Argentina on Sensitive and Multidrug-Resistant Leukemia Cells: Isolation of an Active Principle from Gaillardia megapotamica

    PubMed Central

    González, María Laura; Joray, Mariana Belén; Laiolo, Jerónimo; Crespo, María Inés; Palacios, Sara María; Ruiz, Gustavo Miguel

    2018-01-01

    Plants are a significant reservoir of cytotoxic agents, including compounds with the ability to interfere with multidrug-resistant (MDR) cells. With the aim of finding promising candidates for chemotherapy, 91 native and naturalized plants collected from the central region of Argentina were screened for their cytotoxic effect toward sensitive and MDR P-glycoprotein (P-gp) overexpressing human leukemia cells by means of MTT assays. The ethanol extracts obtained from Aldama tucumanensis, Ambrosia elatior, Baccharis artemisioides, Baccharis coridifolia, Dimerostemma aspilioides, Gaillardia megapotamica, and Vernonanthura nudiflora presented outstanding antiproliferative activity at 50 μg/mL, with inhibitory values from 93 to 100%, when tested on the acute lymphoblastic leukemia (ALL) cell line CCRF-CEM and the resistant derivative CEM-ADR5000, while 70–90% inhibition was observed against the chronic myelogenous leukemia (CML) cell K562 and its corresponding resistant subline, Lucena 1. Subsequent investigation showed these extracts to possess marked cytotoxicity with IC50 values ranging from 0.37 to 29.44 μg/mL, with most of them being below 7 μg/mL and with ALL cells, including the drug-resistant phenotype, being the most affected. G. megapotamica extract found to be one of the most effective and bioguided fractionation yielded helenalin (1). The sesquiterpene lactone displayed IC50 values of 0.63, 0.19, 0.74, and 0.16 μg/mL against K562, CCRF-CEM, Lucena 1, and CEM/ADR5000, respectively. These results support the potential of these extracts as a source of compounds for treating sensitive and multidrug-resistant leukemia cells and support compound 1 as a lead for developing effective anticancer agents. PMID:29861776

  10. Modulation of ceramide metabolism in T-leukemia cell lines potentiates apoptosis induced by the cationic antimicrobial peptide bovine lactoferricin.

    PubMed

    Furlong, Suzanne J; Ridgway, Neale D; Hoskin, David W

    2008-03-01

    Bovine lactoferricin (LfcinB) is a cationic antimicrobial peptide that selectively induces apoptosis in several different types of human cancer cells. However, the potential use of LfcinB as an anticancer agent is presently limited by the need for relatively high concentrations of the peptide to trigger apoptosis. Ceramide is a membrane sphingolipid that is believed to function as a second messenger during apoptosis. In this study, we investigated the role of ceramide in LfcinB-induced apoptosis in CCRF-CEM and Jurkat T-leukemia cell lines. Exposure to LfcinB caused nuclear condensation and fragmentation, poly(ADP-ribose) polymerase (PARP) cleavage, and DNA fragmentation in CCRF-CEM and Jurkat T-cell acute lymphoblastic leukemia cell lines. Treatment with C6 ceramide, a cell-permeable, short-chain ceramide analog, also induced apoptotic nuclear morphology, PARP cleavage, and DNA fragmentation in T-leukemia cells. Although LfcinB treatment did not cause ceramide to accumulate in CCRF-CEM or Jurkat cells, the addition of C6 ceramide to LfcinB-treated T-leukemia cells resulted in increased DNA fragmentation. Furthermore, modulation of cellular ceramide metabolism either by inhibiting ceramidases with D-erythro-2-(N-myristoylamino)-1-phenyl-1-propanol or N-oleoylethanolamine, or by blocking glucosylceramide synthase activity with 1-phenyl-2-palmitoylamino-3-morpholino-1-propanol, enhanced the ability of LfcinB to trigger apoptosis in both Jurkat and CCRF-CEM cells. In addition, LfcinB-induced apoptosis of T-leukemia cells was enhanced in the presence of the antiestrogen tamoxifen, which has multiple effects on cancer cells, including inhibition of glucosylceramide synthase activity. We conclude that manipulation of cellular ceramide levels in combination with LfcinB therapy warrants further investigation as a novel strategy for the treatment of T cell-derived leukemias.

  11. Effect of 2',3'-didehydro-3'-deoxythymidine in an in vitro hollow-fiber pharmacodynamic model system correlates with results of dose-ranging clinical studies.

    PubMed Central

    Bilello, J A; Bauer, G; Dudley, M N; Cole, G A; Drusano, G L

    1994-01-01

    We sought to validate an in vitro system which could predict the minimal effect dose of antiretroviral agents. Mixtures of uninfected CEM cells and CEM cells chronically infected with human immunodeficiency virus (HIV) type 1 MN were exposed to 2',3'-didehydro-3'-deoxythymidine (D4T) in vitro in a hollow-fiber model which simulates the plasma concentration-time profile of D4T in patients. Drug concentration was adjusted to simulate continuous intravenous infusion, or an intravenous bolus administered twice daily. The effect of the dosing regimen was measured with viral infectivity, p24 antigen, and reverse transcriptase or PCR for unintegrated HIV DNA. Dose deescalation studies on a twice-daily dosing schedule predicted a minimum effect dose of 0.5 mg/kg of body weight per day which correlated with the results of a clinical trial. Antiviral effect was demonstrated to be independent of schedule for every 12-h dosing versus continuous infusion. Finally, at or near the minimal effect dose, efficacy appeared to depend on the viral load. The ability of this in vitro pharmacodynamic model to assess the response of HIV-infected cells to different doses and schedules of antiviral agents may be useful in the design of optimal dosing regimens for clinical trials but requires validation with other types of antiretroviral agents. PMID:8092842

  12. Mission Management Computer and Sequencing Hardware for RLV-TD HEX-01 Mission

    NASA Astrophysics Data System (ADS)

    Gupta, Sukrat; Raj, Remya; Mathew, Asha Mary; Koshy, Anna Priya; Paramasivam, R.; Mookiah, T.

    2017-12-01

    Reusable Launch Vehicle-Technology Demonstrator Hypersonic Experiment (RLV-TD HEX-01) mission posed some unique challenges in the design and development of avionics hardware. This work presents the details of mission critical avionics hardware mainly Mission Management Computer (MMC) and sequencing hardware. The Navigation, Guidance and Control (NGC) chain for RLV-TD is dual redundant with cross-strapped Remote Terminals (RTs) interfaced through MIL-STD-1553B bus. MMC is Bus Controller on the 1553 bus, which does the function of GPS aided navigation, guidance, digital autopilot and sequencing for the RLV-TD launch vehicle in different periodicities (10, 20, 500 ms). Digital autopilot execution in MMC with a periodicity of 10 ms (in ascent phase) is introduced for the first time and successfully demonstrated in the flight. MMC is built around Intel i960 processor and has inbuilt fault tolerance features like ECC for memories. Fault Detection and Isolation schemes are implemented to isolate the failed MMC. The sequencing hardware comprises Stage Processing System (SPS) and Command Execution Module (CEM). SPS is `RT' on the 1553 bus which receives the sequencing and control related commands from MMCs and posts to downstream modules after proper error handling for final execution. SPS is designed as a high reliability system by incorporating various fault tolerance and fault detection features. CEM is a relay based module for sequence command execution.

  13. Computational Electromagnetics (CEM) Laboratory: Simulation Planning Guide

    NASA Technical Reports Server (NTRS)

    Khayat, Michael A.

    2011-01-01

    The simulation process, milestones and inputs are unknowns to first-time users of the CEM Laboratory. The Simulation Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their engineering personnel in simulation planning and execution. Material covered includes a roadmap of the simulation process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, facility interfaces, and inputs necessary to define scope, cost, and schedule are included as an appendix to the guide.

  14. Production of Pions in pA-collisions

    NASA Technical Reports Server (NTRS)

    Moskalenko, I. V.; Mashnik, S. G.

    2003-01-01

    Accurate knowledge of pion production cross section in PA-collisions is of interest for astrophysics, CR physics, and space radiation studies. Meanwhile, pion production in pA-reactions is often accounted for by simple scaling of that for pp-collisions, which is not enough for many real applications. We evaluate the quality of existing parameterizations using the data and simulations with the Los Alamos version of the Quark-Gluon String Model code LAQGSM and the improved Cascade-Exciton Model code CEM2k. The LAQGSM and CEM2k models have been shown to reproduce well nuclear reactions and hadronic data in the range 0.01-800 GeV/nucleon.

  15. Conversion electron Mössbauer spectroscopy of plasma immersion ion implanted H13 tool steel

    NASA Astrophysics Data System (ADS)

    Terwagne, G.; Collins, G. A.; Hutchings, R.

    1994-12-01

    Conversion electron Mössbauer spectroscopy (CEMS) has been used to investigate nitride formation in AISI-H13 tool steel after treatment by plasma immersion ion implantation (PI3) at 350 °C. With only slight variation in the plasma conditions, it is possible to influence the kinetics of nitride precipitation so as to obtain nitrogen concentrations that range from those associated with ɛ-Fe2N through ɛ-Fe3N to γ'-Fe4N. The CEMS results enable a more definite identification of the nitrides than that obtained by glancing-angle X-ray diffraction and nuclear reaction analysis alone.

  16. Multipurpose setup for low-temperature conversion electron Mössbauer spectroscopy

    NASA Astrophysics Data System (ADS)

    Augustyns, V.; Trekels, M.; Gunnlaugsson, H. P.; Masenda, H.; Temst, K.; Vantomme, A.; Pereira, L. M. C.

    2017-05-01

    We describe an experimental setup for conversion electron Mössbauer spectroscopy (CEMS) at low temperature. The setup is composed of a continuous flow cryostat (temperature range of 4.2-500 K), detector housing, three channel electron multipliers, and corresponding electronics. We demonstrate the capabilities of the setup with CEMS measurements performed on a sample consisting of a thin enriched 57Fe film, with a thickness of 20 nm, deposited on a silicon substrate. We also describe exchangeable adaptations (lid and sample holder) which extend the applicability of the setup to emission Mössbauer spectroscopy as well as measurements under an applied magnetic field.

  17. Fresh-frozen Complete Extensor Mechanism Allograft versus Autograft Reconstruction in Rabbits

    PubMed Central

    Chen, Guanyin; Zhang, Hongtao; Ma, Qiong; Zhao, Jian; Zhang, Yinglong; Fan, Qingyu; Ma, Baoan

    2016-01-01

    Different clinical results have been reported in the repair of extensor mechanism disruption using fresh-frozen complete extensor mechanism (CEM) allograft, creating a need for a better understanding of fresh-frozen CME allograft reconstruction. Here, we perform histological and biomechanical analyses of fresh-frozen CEM allograft or autograft reconstruction in an in vivo rabbit model. Our histological results show complete incorporation of the quadriceps tendon into the host tissues, patellar survival and total integration of the allograft tibia, with relatively fewer osteocytes, into the host tibia. Vascularity and cellularity are reduced and delayed in the allograft but exhibit similar distributions to those in the autograft. The infrapatellar fat pad provides the main blood supply, and the lowest cellularity is observed in the patellar tendon close to the tibia in both the allograft and autograft. The biomechanical properties of the junction of quadriceps tendon and host tissues and those of the allograft patellar tendon are completely and considerably restored, respectively. Therefore, fresh-frozen CEM allograft reconstruction is viable, but the distal patellar tendon and the tibial block may be the weak links of the reconstruction. These findings provide new insight into the use of allograft in repairing disruption of the extensor mechanism. PMID:26911538

  18. Fresh-frozen Complete Extensor Mechanism Allograft versus Autograft Reconstruction in Rabbits.

    PubMed

    Chen, Guanyin; Zhang, Hongtao; Ma, Qiong; Zhao, Jian; Zhang, Yinglong; Fan, Qingyu; Ma, Baoan

    2016-02-25

    Different clinical results have been reported in the repair of extensor mechanism disruption using fresh-frozen complete extensor mechanism (CEM) allograft, creating a need for a better understanding of fresh-frozen CME allograft reconstruction. Here, we perform histological and biomechanical analyses of fresh-frozen CEM allograft or autograft reconstruction in an in vivo rabbit model. Our histological results show complete incorporation of the quadriceps tendon into the host tissues, patellar survival and total integration of the allograft tibia, with relatively fewer osteocytes, into the host tibia. Vascularity and cellularity are reduced and delayed in the allograft but exhibit similar distributions to those in the autograft. The infrapatellar fat pad provides the main blood supply, and the lowest cellularity is observed in the patellar tendon close to the tibia in both the allograft and autograft. The biomechanical properties of the junction of quadriceps tendon and host tissues and those of the allograft patellar tendon are completely and considerably restored, respectively. Therefore, fresh-frozen CEM allograft reconstruction is viable, but the distal patellar tendon and the tibial block may be the weak links of the reconstruction. These findings provide new insight into the use of allograft in repairing disruption of the extensor mechanism.

  19. The Effect of Different Mixing Methods on Working Time, Setting Time, Dimensional Changes and Film Thickness of Mineral Trioxide Aggregate and Calcium-Enriched Mixture.

    PubMed

    Shahi, Shahriar; Ghasemi, Negin; Rahimi, Saeed; Yavari, Hamidreza; Janani, Maryam; Mokhtari, Hadi; Bahari, Mahmood; Rabbani, Parastu

    2015-01-01

    The aim of the present study was to evaluate the effect of different mixing techniques (conventional, amalgamator and ultrasonic mixing) on the physical properties the working time (WT), setting time (ST), dimensional changes (DC) and film thickness (FT)] of calcium-enriched mixture (CEM) cement and mineral trioxide aggregate (MTA). The mentioned physical properties were determined using the ISO 6786:2001 specification. Six samples of each material were prepared for three mixing techniques (totally 36 samples). Data were analyzed using descriptive statistics, two-way ANOVA and Post Hoc Tukey's tests. The level of significance was defined at 0.05. Irrespective of mixing technique, there was no significant difference between the WT and FT of the tested materials. Except for the DC of MTA and the FT of the all materials, other properties were significantly affected with mixing techniques (P<0.05). The ultrasonic technique decreased the ST of MTA and CEM cement and increased the WT of CEM cement (P<0.05). The mixing technique of the materials had no significant effect on the dimensional changes of MTA and the film thickness of both materials.

  20. Electrophysiological changes correlated with temperature increases induced by high-intensity focused ultrasound ablation.

    PubMed

    Wu, Ziqi; Kumon, Ronald E; Laughner, Jacob I; Efimov, Igor R; Deng, Cheri X

    2015-02-01

    To gain better understanding of the detailed mechanisms of high-intensity focused ultrasound (HIFU) ablation for cardiac arrhythmias, we investigated how the cellular electrophysiological (EP) changes were correlated with temperature increases and thermal dose (cumulative equivalent minutes [CEM43]) during HIFU application using Langendorff-perfused rabbit hearts. Employing voltage-sensitive dye di-4-ANEPPS, we measured the EP and temperature during HIFU using simultaneous optical mapping and infrared imaging. Both action potential amplitude (APA) and action potential duration at 50% repolarization (APD50) decreased with temperature increases, and APD50 was more thermally sensitive than APA. EP and tissue changes were irreversible when HIFU-induced temperature increased above 52.3 ± 1.4°C and log10(CEM43) above 2.16 ± 0.51 (n = 5), but were reversible when temperature was below 50.1 ± 0.8°C and log10(CEM43) below -0.9 ± 0.3 (n = 9). EP and temperature/thermal dose changes were spatially correlated with HIFU-induced tissue necrosis surrounded by a transition zone. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  1. The Chloroplast atpA Gene Cluster in Chlamydomonas reinhardtii1

    PubMed Central

    Drapier, Dominique; Suzuki, Hideki; Levy, Haim; Rimbault, Blandine; Kindle, Karen L.; Stern, David B.; Wollman, Francis-André

    1998-01-01

    Most chloroplast genes in vascular plants are organized into polycistronic transcription units, which generate a complex pattern of mono-, di-, and polycistronic transcripts. In contrast, most Chlamydomonas reinhardtii chloroplast transcripts characterized to date have been monocistronic. This paper describes the atpA gene cluster in the C. reinhardtii chloroplast genome, which includes the atpA, psbI, cemA, and atpH genes, encoding the α-subunit of the coupling-factor-1 (CF1) ATP synthase, a small photosystem II polypeptide, a chloroplast envelope membrane protein, and subunit III of the CF0 ATP synthase, respectively. We show that promoters precede the atpA, psbI, and atpH genes, but not the cemA gene, and that cemA mRNA is present only as part of di-, tri-, or tetracistronic transcripts. Deletions introduced into the gene cluster reveal, first, that CF1-α can be translated from di- or polycistronic transcripts, and, second, that substantial reductions in mRNA quantity have minimal effects on protein synthesis rates. We suggest that posttranscriptional mRNA processing is common in C. reinhardtii chloroplasts, permitting the expression of multiple genes from a single promoter. PMID:9625716

  2. Influence of Cements Containing Calcareous Fly Ash as a Main Component Properties of Fresh Cement Mixtures

    NASA Astrophysics Data System (ADS)

    Gołaszewski, Jacek; Kostrzanowska-Siedlarz, Aleksandra; Ponikiewski, Tomasz; Miera, Patrycja

    2017-10-01

    The main goal of presented research was to examine usability of cements containing calcareous fly ash (W) from technological point of view. In the paper the results of tests concerning the influence of CEM II and CEM IV cements containing fly ash (W) on rheological properties, air content, setting times and plastic shrinkage of mortars are presented and discussed. Moreover, compatibility of plasticizers with cements containing fly ash (W) was also studied. Additionally, setting time and hydration heat of cements containing calcareous fly ash (W) were determined. In a broader aspect, the research contributes to promulgation of the possibility of using calcareous fly ash (W) in cement and concrete technology, what greatly benefits the environment protection (utilization of waste fly ash). Calcareous fly ash can be used successfully as the main component of cement. Cements produced by blending with processed fly ash or cements produced by interginding are characterized by acceptable technological properties. In respect to CEM I cements, cements containing calcareous fly ash worsen workability, decrease air content, delay setting time of mixtures. Cements with calcareous fly ash show good compatibility with plasticizers.

  3. 57Fe CEMS study on dilute metal ions codoped SnO2 thin films prepared by spray pyrolysis

    NASA Astrophysics Data System (ADS)

    Nomura, Kiyoshi; Koike, Yuya; Nakanishi, Akio

    2017-11-01

    Dilute Mn-Fe, Co-Fe and V-Fe codoped tin oxide films prepared by spray pyrolysis were characterized by 57Fe conversion electron Mössbauer spectrometry (CEMS) at room temperature (RT) and at 20 K. Two kinds of paramagnetic Fe3+ species were detected at RT; one doublet 1 (D1) with IS = 0.36-0.37 mm/s, QS = 0.69-0.75 mm/s and LW = 0.32-0.40 mm/s, and another doublet 2 (D2) with IS = 0.31-0.35 mm/s QS = 1.16-1.25 mm/s and LW = 0.46-0.52 mm/s. CEMS at 20 K provided more distinguished doublets than at RT. It is found that especially D2 with relatively small IS and large QS values are influenced by other metal ions codoped in SnO2 matrix, whereas D1 with relatively large IS and small QS has the parameters close to the models of Fe-VO1 and Fe-2VO1-Fe models (Nomura et al. Phys. Rev. B 75, 184411 2007; Mudarra Navarro et al. J. Phys. Chem. C 119, 5596-5603 2015).

  4. Cooperative enhancement of the nonlinear optical response in conjugated energetic materials: A TD-DFT study

    DOE PAGES

    Sifain, Andrew E.; Tadesse, Loza F.; Bjorgaard, Josiah August; ...

    2017-03-21

    Conjugated energetic molecules (CEMs) are a class of explosives with high nitrogen content that posses both enhanced safety and energetic performance properties and are ideal for direct optical initiation. As isolated molecules, they absorb within the range of conventional lasers. Crystalline CEMs are used in practice, however, and their properties can differ due to intermolecular interaction. Herein, time-dependent density functional theory was used to investigate one-photon absorption (OPA) and two-photon absorption (TPA) of monomers and dimers obtained from experimentally determined crystal structures of CEMs. OPA scales linearly with the number of chromophore units, while TPA scales nonlinearly, where a moremore » than 3-fold enhancement in peak intensity, per chromophore unit, is calculated. Cooperative enhancement depends on electronic delocalization spanning both chromophore units. An increase in sensitivity to nonlinear laser initiation makes these materials suitable for practical use. This is the first study predicting a cooperative enhancement of the nonlinear optical response in energetic materials composed of relatively small molecules. Finally, the proposed model quantum chemistry is validated by comparison to crystal structure geometries and the optical absorption of these materials dissolved in solution.« less

  5. SEM evaluation of pulp reaction to different pulp capping materials in dog’s teeth

    PubMed Central

    Asgary, Saeed; Parirokh, Masoud; Eghbal, Mohammad Jafar; Ghoddusi, Jamileh

    2006-01-01

    Introduction: This investigation evaluates the effects of mineral trioxide aggregate (MTA), calcium hydroxide (CH) and calcium enriched mixture (CEM) as pulp capping materials on dental pulp tissues. Materials and Methods: The experimental procedures were performed on eighteen intact dog canine teeth. The pulps were exposed. Cavities were randomly filled with CEM, MTA, or CH followed by glass ionomer filling. After 2 months, animals were sacrificed, each tooth was sectioned into halves, and the interface between each capping material and pulp tissue was evaluated by scanning electron microscope (SEM) in profile view of the specimens. Results: Dentinal bridge formation as the most characteristic reaction was resulted from SEM observation in all examined groups. Odontoblast-like cells were formed and create dens collagen network, which was calcified gradually by deposition of calcosphirit structures to form newly dentinal bridge. Conclusion: Based on the results of this in vivo study, it was concluded that these test materials are able to produce calcified tissue in underlying pulp in the case of being used as a pulp capping agent. Additionally, it appears that CEM has the potential to be used as a direct pulp capping material during vital pulp therapy. PMID:24379876

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Funsten, Herbert O.; Harper, Ronnie W.; Dors, Eric E.

    Channel electron multiplier (CEM) and microchannel plate (MCP) detectors are routinely used in space instrumentation for measurement of space plasmas. Here, our goal is to understand the relative sensitivities of these detectors to penetrating radiation in space, which can generate background counts and shorten detector lifetime. We use 662 keV γ-rays as a proxy for penetrating radiation such as γ-rays, cosmic rays, and high-energy electrons and protons that are ubiquitous in the space environment. We find that MCP detectors are ~20 times more sensitive to 662 keV γ-rays than CEM detectors. This is attributed to the larger total area ofmore » multiplication channels in an MCP detector that is sensitive to electronic excitation and ionization resulting from the interaction of penetrating radiation with the detector material. In contrast to the CEM detector, whose quantum efficiency ε γ for 662 keVγ -rays is found to be 0.00175 and largely independent of detector bias, the quantum efficiency of the MCP detector is strongly dependent on the detector bias, with a power law index of 5.5. Lastly, background counts in MCP detectors from penetrating radiation can be reduced using MCP geometries with higher pitch and smaller channel diameter.« less

  7. Indication for double parton scatterings in W+ prompt J/ψ production at the LHC

    NASA Astrophysics Data System (ADS)

    Lansberg, Jean-Philippe; Shao, Hua-Sheng; Yamanaka, Nodoka

    2018-06-01

    We re-analyse the associated production of a prompt J / ψ and a W boson in pp collisions at the LHC following the results of the ATLAS Collaboration. We perform the first study of the Single-Parton-Scattering (SPS) contributions at the Next-to-Leading Order (NLO) in αs in the Colour-Evaporation Model (CEM), an approach based on the quark-hadron-duality. Our study provides clear indications for Double-Parton-Scattering (DPS) contributions, in particular at low transverse momenta, since our SPS CEM evaluation, which can be viewed as a conservative upper limit of the SPS yields, falls short compared to the ATLAS experimental data by 3.1 standard deviations. We also determine a finite allowed region for σeff, inversely proportional to the size of the DPS yields, corresponding to the otherwise opposed hypotheses, namely our NLO CEM evaluation and the LO direct Colour-Singlet (CS) Model contribution. In both cases, the resulting DPS yields are significantly larger than that initially assumed by ATLAS based on jet-related analyses but is consistent with their observed raw-yield azimuthal distribution and with their prompt J / ψ + J / ψ and Z+ prompt J / ψ data.

  8. Sheathless interface to match flow rate of capillary electrophoresis with electrospray mass spectrometry using regular-sized capillary.

    PubMed

    Yin, Yue; Li, Gongyu; Guan, Yafeng; Huang, Guangming

    2016-08-01

    The flow rate match has been a great challenge when coupling capillary electrophoresis (CE) with electrospray ionization mass spectrometry (ESI-MS). Conventional CE-ESI-MS interfaces used liquid sheath flow, narrowed capillary or additional pressure to meet this requirement; sacrifice of either capillary inner diameter (i.d.) or separation efficiency is often inevitable. Thus, a regular-sized capillary-based sheathless interface would be attractive for flow rate match in CE-MS. The regular-sized capillary-based CE-MS interface was achieved by coupling CE with induced electrospray ionization (iESI) which was stimulated by the fact that the iESI could both achieve flow rate down to 0.2 μL/min and retain ionization efficiency. The CE-iESI-MS interface was completed with an intact separation capillary, outside the outlet end of which a metal electrode was attached for the application of alternating current (ac) high voltage (HV). The feasibility of this CE-iESI-MS interface was demonstrated through the stable total ion chromatograms obtained by continuous CE infusion of tripropylamine with regular-sized capillaries. Tripropylamine and atenolol were separated and detected successfully in phosphate buffer solution (PBS) by CE-iESI-MS using a 50 or 75 μm i.d. capillary. Furthermore, this new interface showed a better signal-to-noise (S/N) of 3 to 7 times enhancement compared with another sheathless CE-ESI-MS interface that using one high voltage for both separation and electrospray when analyzing the mixture of tripropylamine and proline in NH4 OAc buffer. In addition, the reproducibility of this interface gave satisfactory results with relative standard deviation (RSD) in retention time in the range between 1% and 3%. The novel sheathless CE-MS interface introduced here could match conventional electroosmotic flow (EOF) with electrospray which could also preserve the separation efficiency and sensitivity of CE-MS. This newly developed CE-iESI-MS interface was also demonstrated to be effective for different buffers, PBS and NH4 OAc, without any additives such as methanol and acetic acid. Hence, we believe that this sheathless CE-MS interface could be operated with other nonvolatile and volatile buffers. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  9. Analytical methods for multiresidue determination of sulfonamides and trimethoprim in meat and ground water samples by CE-MS and CE-MS/MS.

    PubMed

    Soto-Chinchilla, Jorge J; García-Campaña, Ana M; Gámiz-Gracia, Laura

    2007-11-01

    This paper presents two methods based on CZE-MS detection and CZE-MS/MS detection developed for the multiresidue determination of ten sulfonamides (sulfapyridine, sulfadoxin, sulfamethazine, sulfadimethoxine, sulfameter, sulfamerazine, sulfachlorpyridazine, sulfadiazine, sulfamethoxazole, and sulfamethizole) and a potentiator, trimethoprim (TMP), whose contents are regulated by the EU Council Regulation no. 2377/90 in animal edible tissues. Experimental designs were employed to optimize the electrospray conditions. MS/MS experiments using an IT as analyzer operating in multiple reaction monitoring (MRM) mode were carried out to achieve the minimum number of points according to the 2002/657/EC European Decision for unambiguous identification. The proposed procedures have been compared in terms of the performance characteristics and trueness. The limits of detection and quantification were in all cases lower than the maximum residue limits legislated for these compounds and the recoveries were satisfactory, being possible the application for their monitoring in foodstuff of animal origin and in environmental samples, allowing the determination of sulfonamides and TMP residues in meat and in superficial water in the low microg/L range.

  10. CE-UV/VIS and CE-MS for monitoring organic impurities during the downstream processing of fermentative-produced lactic acid from second-generation renewable feedstocks.

    PubMed

    Laube, Hendrik; Matysik, Frank-Michael; Schmidberger, Andreas; Mehlmann, Kerstin; Toursel, Andreas; Boden, Jana

    2016-01-01

    During the downstream process of bio-based bulk chemicals, organic impurities, mostly residues from the fermentation process, must be separated to obtain a pure and ready-to-market chemical. In this study, capillary electrophoresis was investigated for the non-targeting downstream process monitoring of organic impurities and simultaneous quantitative detection of lactic acid during the purification process of fermentatively produced lactic acid. The downstream process incorporated 11 separation units, ranging from filtration, adsorption and ion exchange to electrodialysis and distillation, and 15 different second-generation renewable feedstocks were processed into lactic acid. The identification of organic impurities was established through spiking and the utilization of an advanced capillary electrophoresis mass spectrometry system. A total of 53 % of the organic impurities were efficiently removed via bipolar electrodialysis; however, one impurity, pyroglutamic acid, was recalcitrant to separation. It was demonstrated that the presence of pyroglutamic acid disrupts the polymerization of lactic acid into poly lactic acid. Pyroglutamic acid was present in all lactic acid solutions, independent of the type of renewable resource or the bacterium applied. Pyroglutamic acid, also known as 5-oxoproline, is a metabolite in the glutathione cycle, which is present in all living microorganisms. pyroglutamic acid is found in many proteins, and during intracellular protein metabolism, N-terminal glutamic acid and glutamine residues can spontaneously cyclize to become pyroglutamic acid. Hence, the concentration of pyroglutamic acid in the lactic acid solution can only be limited to a certain amount. The present study proved the capillary electrophoresis system to be an important tool for downstream process monitoring. The high product concentration encountered in biological production processes did not hinder the capillary electrophoresis from separating and detecting organic impurities, even at minor concentrations. The coupling of the capillary electrophoresis with a mass spectrometry system allowed for the straightforward identification of the remaining critical impurity, pyroglutamic acid. Although 11 separation units were applied during the downstream process, the pyroglutamic acid concentration remained at 12,900 ppm, which was comparatively high. All organic impurities found were tracked by the capillary electrophoresis, allowing for further separation optimization.

  11. Genotoxic properties of haloacetonitriles: drinking water by-products of chlorine disinfection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daniel, F.B.; Schenck, K.M.; Mattox, J.K.

    Chlorinated and brominated haloacetonitriles (HAN), known drinking water contaminants which form during chlorine disinfection, were investigated for genotoxic activity. The HAN produced DNA strand breaks in cultured human lymphoblastic (CCRF-CEM) cells, bound to the nucleophilic trapping agent 4-(p-nitrobenzyl)pyridine and formed a covalent bond to polyadenylic acid in a cell-free reaction system. Thus, we have demonstrated that these chemicals are genotoxic, which would indicate a potential for carcinogenic activity and for human health hazard.

  12. Why give birth in health facility? Users’ and providers’ accounts of poor quality of birth care in Tanzania

    PubMed Central

    2013-01-01

    Background In Tanzania, half of all pregnant women access a health facility for delivery. The proportion receiving skilled care at birth is even lower. In order to reduce maternal mortality and morbidity, the government has set out to increase health facility deliveries by skilled care. The aim of this study was to describe the weaknesses in the provision of acceptable and adequate quality care through the accounts of women who have suffered obstetric fistula, nurse-midwives at both BEmOC and CEmOC health facilities and local community members. Methods Semi-structured interviews involving 16 women affected by obstetric fistula and five nurse-midwives at maternity wards at both BEmOC and CEmOC health facilities, and Focus Group Discussions with husbands and community members were conducted between October 2008 and February 2010 at Comprehensive Community Based Rehabilitation in Tanzania and Temeke hospitals in Dar es Salaam, and Mpwapwa district in Dodoma region. Results Health care users and health providers experienced poor quality caring and working environments in the health facilities. Women in labour lacked support, experienced neglect, as well as physical and verbal abuse. Nurse-midwives lacked supportive supervision, supplies and also seemed to lack motivation. Conclusions There was a consensus among women who have suffered serious birth injuries and nurse midwives staffing both BEmOC and CEmOC maternity wards that the quality of care offered to women in birth was inadequate. While the birth accounts of women pointed to failure of care, the nurses described a situation of disempowerment. The bad birth care experiences of women undermine the reputation of the health care system, lower community expectations of facility birth, and sustain high rates of home deliveries. The only way to increase the rate of skilled attendance at birth in the current Tanzanian context is to make facility birth a safer alternative than home birth. The findings from this study indicate that there is a long way to go. PMID:23663299

  13. Physico-chemical interactions at the concrete-bitumen interface of nuclear waste repositories

    NASA Astrophysics Data System (ADS)

    Bertron, A.; Ranaivomanana, H.; Jacquemet, N.; Erable, B.; Sablayrolles, C.; Escadeillas, G.; Albrecht, A.

    2013-07-01

    This study investigates the fate of nitrate and organic acids at the bitumenconcrete-steel interface within a repository storage cell for long-lived, intermediatelevel, radioactive wastes. The interface was simulated by a multiphase system in which cementitious matrices (CEM V-paste specimens) were exposed to bitumen model leachates consisting of nitrates and acetic acid with and without oxalic acid, chemical compounds likely to be released by bitumen. Leaching experiments were conducted with daily renewal of the solutions in order to accelerate reactions. C-steel chips, simulating the presence of steel in the repository, were added in the systems for some experiments. The concentrations of anions (acetate, oxalate, nitrate, and nitrite) and cations (calcium, potassium, ammonium) and the pH were monitored over time. Mineralogical changes of the cementitious matrices were analysed by XRD. The results confirmed the stability of nitrates in the absence of steel, whereas, reduction of nitrates was observed in the presence of steel (production of NH4+). The action of acetic acid on the cementitious matrix was similar to that of ordinary leaching; no specific interaction was detected between acetate and cementitious cations. The reaction of oxalic acid with the cementitious phases led to the precipitation of calcium oxalate salts in the outer layer of the matrix. The concentration of oxalate was reduced by 65% inside the leaching medium.

  14. Constant Group Velocity Ultrasonic Guided Wave Inspection for Corrosion and Erosion Monitoring in Pipes

    NASA Astrophysics Data System (ADS)

    Instanes, Geir; Pedersen, Audun; Toppe, Mads; Nagy, Peter B.

    2009-03-01

    This paper describes a novel ultrasonic guided wave inspection technique for the monitoring of internal corrosion and erosion in pipes, which exploits the fundamental flexural mode to measure the average wall thickness over the inspection path. The inspection frequency is chosen so that the group velocity of the fundamental flexural mode is essentially constant throughout the wall thickness range of interest, while the phase velocity is highly dispersive and changes in a systematic way with varying wall thickness in the pipe. Although this approach is somewhat less accurate than the often used transverse resonance methods, it smoothly integrates the wall thickness over the whole propagation length, therefore it is very robust and can tolerate large and uneven thickness variations from point to point. The constant group velocity (CGV) method is capable of monitoring the true average of the wall thickness over the inspection length with an accuracy of 1% even in the presence of one order of magnitude larger local variations. This method also eliminates spurious variations caused by changing temperature, which can cause fairly large velocity variations, but do not significantly influence the dispersion as measured by the true phase angle in the vicinity of the CGV point. The CGV guided wave CEM method was validated in both laboratory and field tests.

  15. Dating silk by capillary electrophoresis mass spectrometry.

    PubMed

    Moini, Mehdi; Klauenberg, Kathryn; Ballard, Mary

    2011-10-01

    A new capillary electrophoresis mass spectrometry (CE-MS) technique is introduced for age estimation of silk textiles based on amino acid racemization rates. With an L to D conversion half-life of ~2500 years for silk (B. mori) aspartic acid, the technique is capable of dating silk textiles ranging in age from several decades to a few-thousand-years-old. Analysis required only ~100 μg or less of silk fiber. Except for a 2 h acid hydrolysis at 110 °C, no other sample preparation is required. The CE-MS analysis takes ~20 min, consumes only nanoliters of the amino acid mixture, and provides both amino acid composition profiles and D/L ratios for ~11 amino acids.

  16. Toxecon Retrofit for Mercury and Mulit-Pollutant Control on Three 90-MW Coal-Fired Boilers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steven Derenne; Robin Stewart

    2009-09-30

    This U.S. Department of Energy (DOE) Clean Coal Power Initiative (CCPI) project was based on a cooperative agreement between We Energies and the DOE Office of Fossil Energy's National Energy Technology Laboratory (NETL) to design, install, evaluate, and demonstrate the EPRI-patented TOXECON{trademark} air pollution control process. Project partners included Cummins & Barnard, ADA-ES, and the Electric Power Research Institute (EPRI). The primary goal of this project was to reduce mercury emissions from three 90-MW units that burn Powder River Basin coal at the We Energies Presque Isle Power Plant in Marquette, Michigan. Additional goals were to reduce nitrogen oxide (NO{submore » x}), sulfur dioxide (SO{sub 2}), and particulate matter emissions; allow reuse and sale of fly ash; advance commercialization of the technology; demonstrate a reliable mercury continuous emission monitor (CEM) suitable for use at power plants; and demonstrate recovery of mercury from the sorbent. Mercury was controlled by injection of activated carbon upstream of the TOXECON{trademark} baghouse, which achieved more than 90% removal on average over a 44-month period. During a two-week test involving trona injection, SO{sub 2} emissions were reduced by 70%, although no coincident removal of NOx was achieved. The TOXECON{trademark} baghouse also provided enhanced particulate control, particularly during startup of the boilers. On this project, mercury CEMs were developed and tested in collaboration with Thermo Fisher Scientific, resulting in a reliable CEM that could be used in the power plant environment and that could measure mercury as low as 0.1 {micro}g/m{sup 3}. Sorbents were injected downstream of the primary particulate collection device, allowing for continued sale and beneficial use of captured fly ash. Two methods for recovering mercury using thermal desorption on the TOXECON{trademark} PAC/ash mixture were successfully tested during this program. Two methods for using the TOXECON{trademark} PAC/ash mixture in structural concrete were also successfully developed and tested. This project demonstrated a significant reduction in the rate of emissions from Presque Isle Units 7, 8, and 9, and substantial progress toward establishing the design criteria for one of the most promising mercury control retrofit technologies currently available. The Levelized Cost for 90% mercury removal at this site was calculated at $77,031 per pound of mercury removed with a capital cost of $63,189 per pound of mercury removed. Mercury removal at the Presque Isle Power Plant averages approximately 97 pounds per year.« less

  17. [Experimental study on TCRbeta idiotypic antigenic determinants DNA vaccine to induce anti-lymphoma antibodies].

    PubMed

    Zhang, Yeping; Zhu, Ping; Shi, Yongjin; Liu, Jihua; Pu, Dingfang; Cao, Xianghong; Zhu, Qiang; Wang, Yijia; Ma, Mingxin; Yu, Jiren

    2002-02-01

    To investigate the anti-human CEM lymphoma cell activities induced by TCR idiotypic DNA vaccine containing different antigen determinants in BALB/c mice. The specific rearranged gene fragment encoding TCRVbeta region of CEM cell line was obtained by RT-PCR technique. The PCR product was cloned into eukaryocytic expression vector pcDNA3, which was used as DNA vaccine and template for PCR amplifying different antigen determinant. Gene fragments encoding different antigen determinant were amplified and cloned into pcDNA3, separately. The experimental mice were immunized by intramuscular injection of the DNA vaccines. The specific anti-idiotype antibodies were detected by indirect immunofluorescence assay. TCRbetaV of CEM cell line contains five antigen determinants. Specific anti-idiotype antibody was detected in all of the six mice immunized with DNA vaccine containing all the five determinants (the highest titer was 1:480). Although the antibody could also be detected in four of the six mice immunized with DNA vaccine containing four of the five antigen determinants, the antibody titer was lower (the highest titer was 1:80). DNA vaccine containing two of the five determinants could not induce the specific antibody. The idiotypic DNA vaccine containing the whole TCRbetaV five antigen determinants could induce the specific anti-lymphoma idiotypic antibody in BALB/c mice.

  18. Life cycle energy efficiency and environmental impact assessment of bioethanol production from sweet potato based on different production modes

    PubMed Central

    Zhang, Jun; Jia, Chunrong; Wu, Yi; Xi, Beidou; Wang, Lijun; Zhai, Youlong

    2017-01-01

    The bioethanol is playing an increasingly important role in renewable energy in China. Based on the theory of circular economy, integration of different resources by polygeneration is one of the solutions to improve energy efficiency and to reduce environmental impact. In this study, three modes of bioethanol production were selected to evaluate the life cycle energy efficiency and environmental impact of sweet potato-based bioethanol. The results showed that, the net energy ratio was greater than 1 and the value of net energy gain was positive in the three production modes, in which the maximum value appeared in the circular economy mode (CEM). The environment emission mainly occurred to bioethanol conversion unit in the conventional production mode (CPM) and the cogeneration mode (CGM), and eutrophication potential (EP) and global warming potential (GWP) were the most significant environmental impact category. While compared with CPM and CGM, the environmental impact of CEM significantly declined due to increasing recycling, and plant cultivation unit mainly contributed to EP and GWP. And the comprehensive evaluation score of environmental impact decreased by 73.46% and 23.36%. This study showed that CEM was effective in improving energy efficiency, especially in reducing the environmental impact, and it provides a new method for bioethanol production. PMID:28672044

  19. Comparative Response of Microchannel Plate and Channel Electron Multiplier Detectors to Penetrating Radiation in Space

    DOE PAGES

    Funsten, Herbert O.; Harper, Ronnie W.; Dors, Eric E.; ...

    2015-10-02

    Channel electron multiplier (CEM) and microchannel plate (MCP) detectors are routinely used in space instrumentation for measurement of space plasmas. Here, our goal is to understand the relative sensitivities of these detectors to penetrating radiation in space, which can generate background counts and shorten detector lifetime. We use 662 keV γ-rays as a proxy for penetrating radiation such as γ-rays, cosmic rays, and high-energy electrons and protons that are ubiquitous in the space environment. We find that MCP detectors are ~20 times more sensitive to 662 keV γ-rays than CEM detectors. This is attributed to the larger total area ofmore » multiplication channels in an MCP detector that is sensitive to electronic excitation and ionization resulting from the interaction of penetrating radiation with the detector material. In contrast to the CEM detector, whose quantum efficiency ε γ for 662 keVγ -rays is found to be 0.00175 and largely independent of detector bias, the quantum efficiency of the MCP detector is strongly dependent on the detector bias, with a power law index of 5.5. Lastly, background counts in MCP detectors from penetrating radiation can be reduced using MCP geometries with higher pitch and smaller channel diameter.« less

  20. Child abuse and negative explicit and automatic self-associations: the cognitive scars of emotional maltreatment.

    PubMed

    van Harmelen, Anne-Laura; de Jong, Peter J; Glashouwer, Klaske A; Spinhoven, Philip; Penninx, Brenda W J H; Elzinga, Bernet M

    2010-06-01

    Individuals reporting Childhood Abuse (CA) (i.e., emotional neglect, emotional-, physical- and sexual-abuse) are marked by increased explicit (i.e. self-reported) negative self-associations, and an increased risk to develop depression or anxiety disorders. Automatic self-associations might play an important role in the development and maintenance of affective disorders after exposure to CA, since automatic associations are assumed to be involved in uncontrolled (spontaneous) affective behavior. This study examined whether individuals reporting a history of CA show stronger automatic (and explicit) self-depression and/or self-anxiety associations than individuals who report no CA in a large cohort study (Netherlands Study of Depression and Anxiety (NESDA), n = 2981). The Implicit Association Test (IAT) was utilized to assess automatic self-depression and self-anxiety associations. We found that CA was associated with enhanced automatic (and explicit) self-depression and self-anxiety associations. Additionally, when compared to physical- and sexual-abuse, Childhood Emotional Maltreatment (CEM; emotional abuse and emotional neglect) had the strongest link with enhanced automatic (and explicit) self-depression and self-anxiety associations. In addition, automatic and explicit negative self-associations partially mediated the association between CEM and depressive or anxious symptomatology. Implications regarding the importance of CA, and CEM in particular will be discussed. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  1. MCNP6 Simulation of Light and Medium Nuclei Fragmentation at Intermediate Energies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mashnik, Stepan Georgievich; Kerby, Leslie Marie

    2015-05-22

    MCNP6, the latest and most advanced LANL Monte Carlo transport code, representing a merger of MCNP5 and MCNPX, is actually much more than the sum of those two computer codes; MCNP6 is available to the public via RSICC at Oak Ridge, TN, USA. In the present work, MCNP6 was validated and verified (V&V) against different experimental data on intermediate-energy fragmentation reactions, and results by several other codes, using mainly the latest modifications of the Cascade-Exciton Model (CEM) and of the Los Alamos version of the Quark-Gluon String Model (LAQGSM) event generators CEM03.03 and LAQGSM03.03. It was found that MCNP6 usingmore » CEM03.03 and LAQGSM03.03 describes well fragmentation reactions induced on light and medium target nuclei by protons and light nuclei of energies around 1 GeV/nucleon and below, and can serve as a reliable simulation tool for different applications, like cosmic-ray-induced single event upsets (SEU’s), radiation protection, and cancer therapy with proton and ion beams, to name just a few. Future improvements of the predicting capabilities of MCNP6 for such reactions are possible, and are discussed in this work.« less

  2. Life cycle energy efficiency and environmental impact assessment of bioethanol production from sweet potato based on different production modes.

    PubMed

    Zhang, Jun; Jia, Chunrong; Wu, Yi; Xia, Xunfeng; Xi, Beidou; Wang, Lijun; Zhai, Youlong

    2017-01-01

    The bioethanol is playing an increasingly important role in renewable energy in China. Based on the theory of circular economy, integration of different resources by polygeneration is one of the solutions to improve energy efficiency and to reduce environmental impact. In this study, three modes of bioethanol production were selected to evaluate the life cycle energy efficiency and environmental impact of sweet potato-based bioethanol. The results showed that, the net energy ratio was greater than 1 and the value of net energy gain was positive in the three production modes, in which the maximum value appeared in the circular economy mode (CEM). The environment emission mainly occurred to bioethanol conversion unit in the conventional production mode (CPM) and the cogeneration mode (CGM), and eutrophication potential (EP) and global warming potential (GWP) were the most significant environmental impact category. While compared with CPM and CGM, the environmental impact of CEM significantly declined due to increasing recycling, and plant cultivation unit mainly contributed to EP and GWP. And the comprehensive evaluation score of environmental impact decreased by 73.46% and 23.36%. This study showed that CEM was effective in improving energy efficiency, especially in reducing the environmental impact, and it provides a new method for bioethanol production.

  3. Method development of enantiomer separations by affinity capillary electrophoresis, cyclodextrin electrokinetic chromatography and capillary electrophoresis-mass spectrometry.

    PubMed

    Tanaka, Yoshihide

    2002-07-01

    Capillary electrophoresis (CE) has become a powerful tool for enantiomer separations during the last decade. Since 1993, the author has investigated enantiomer separations by affinity capillary electrophoresis (affinity CE) with some proteins and by cyclodextrin electrokinetic chromatography (CDEKC) with some charged cyclodextrins (CDs). Many successful enantiomer separations are demonstrated from our study in this review article. In the enantiomer separations by affinity CE, the deterioration of detection sensitivity was observed under high concentration of the protein in running solutions. The partial filling technique was practically useful to solve the serious problem. It allowed operation at high protein concentrations, such as 500 mumol/L, without the detection problem. Charged CDs had several advantages for the enantiomer separations over neutral ones. Strong electrostatic interactions between a charged CD and oppositely charged analytes should be effective for the formation of the complex. A large difference in electrophoretic mobility between the free analyte and the inclusion complex should also enhance the enantiomeric resolution. In CE-mass spectrometry (CE-MS), the partial filling technique was applied to avoid the introduction of nonvolatile chiral selectors into the CE-MS interface. By replacing the nonvolatile electrolytes in the running buffer by volatile ones, the separation conditions employed in CE with the UV detection method could be transferred to CE-MS.

  4. Chemical synthesis of a very long oligoribonucleotide with 2-cyanoethoxymethyl (CEM) as the 2′-O-protecting group: structural identification and biological activity of a synthetic 110mer precursor-microRNA candidate

    PubMed Central

    Shiba, Yoshinobu; Masuda, Hirofumi; Watanabe, Naoki; Ego, Takeshi; Takagaki, Kazuchika; Ishiyama, Kouichi; Ohgi, Tadaaki; Yano, Junichi

    2007-01-01

    A long RNA oligomer, a 110mer with the sequence of a precursor-microRNA candidate, has been chemically synthesized in a single synthesizer run by means of standard automated phosphoramidite chemistry. The synthetic method involved the use of 2-cyanoethoxymethyl (CEM), a 2′-hydroxyl protecting group recently developed in our laboratory. We improved the methodology, introducing better coupling and capping conditions. The overall isolated yield of highly pure 110mer was 5.5%. Such a yield on a 1-μmol scale corresponds to 1 mg of product and emphasizes the practicality of the CEM method for synthesizing oligomers of more than 100 nt in sufficient quantity for biological research. We confirmed the identity of the 110mer by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry, as well as HPLC, electrophoretic methods, and RNase-digestion experiments. The 110mer also showed sense-selective specific gene-silencing activity. As far as we know, this is the longest chemically synthesized RNA oligomer reported to date. Furthermore, the identity of the 110mer was confirmed by both physicochemical and biological methods. PMID:17459888

  5. Looking into aqueous humor through metabolomics spectacles - exploring its metabolic characteristics in relation to myopia.

    PubMed

    Barbas-Bernardos, Cecilia; Armitage, Emily G; García, Antonia; Mérida, Salvador; Navea, Amparo; Bosch-Morell, Francisco; Barbas, Coral

    2016-08-05

    Aqueous humor is the transparent fluid found in the anterior chamber of the eye that provides the metabolic requirements to the avascular tissues surrounding it. Despite the fact that metabolomics could be a powerful tool in the characterization of this biofluid and in revealing metabolic signatures of common ocular diseases such as myopia, it has never to our knowledge previously been applied in humans. In this research a novel method for the analysis of aqueous humor is presented to show its application in the characterization of this biofluid using CE-MS. The method was extended to a dual platform method (CE-MS and LC-MS) in order to compare samples from patients with different severities of myopia in order to explore the disease from the metabolic phenotype point of view. With this method, a profound knowledge of the metabolites present in human aqueous humor has been obtained: over 40 metabolites were reproducibly and simultaneously identified from a low volume of sample by CE-MS, including among others, a vast number of amino acids and derivatives. When this method was extended to study groups of patients with high or low myopia in both CE-MS and LC-MS, it has been possible to identify over 20 significantly different metabolite and lipid signatures that distinguish patients based on the severity of myopia. Among these, the most notable higher abundant metabolites in high myopia were aminooctanoic acid, arginine, citrulline and sphinganine while features of low myopia were aminoundecanoic acid, dihydro-retinoic acid and cysteinylglycine disulfide. This dual platform approach offered complementarity such that different metabolites were detected in each technique. Together the experiments presented provide a whelm of valuable information about human aqueous humor and myopia, proving the utility of non-targeted metabolomics for the first time in analyzing this type of sample and the metabolic phenotype of this disease. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Comparative Analysis of Arterial Parameters Variations Associated with Inter-Individual Variations in Peripheral and Aortic Blood Pressure: Cross-Sectional Study in Healthy Subjects Aged 2-84 years.

    PubMed

    Zócalo, Yanina; Curcio, Santiago; García-Espinosa, Victoria; Chiesa, Pedro; Giachetto, Gustavo; Bia, Daniel

    2017-12-01

    The association between arterial parameters and blood pressure (BP) interindividual variations could depend on the arterial segment, BP component (systolic, SBP; diastolic, DBP; pulse pressure, PP) and/or on whether central (cBP) or peripheral (pBP) BP variations are considered. To assess and compare arterial parameters variations associated with interindividual variations in cBP and pBP. Healthy subjects (n = 923; 488 males, 2-84 years) were included. pBP and cBP waves were obtained (Mobil-O-Graph; SphygmoCor). Arterial diameter, intima-media thickness, local elastic modulus (carotid, CEM; brachial, BEM; femoral, FEM) and regional (carotid-radial and carotid-femoral pulse wave velocity; crPWV and cfPWV) arterial stiffness were determined. Associations between BP and arterial parameters interindividual variations were analyzed and compared (correlations; linear regressions; slopes comparisons) considering data transformed into z-scores. Given a variation in z-cSBP or z-pSBP, z-CEM, z-FEM and z-cfPWV (stiffness indexes), were among the parameters with major BP-associated variations. z-crPWV and z-cfPWV, rather than local stiffness indexes were the parameters with major variations associated with z-DBP variations. z-cPP or z-pPP were associated with z-CEM and z-FEM variations, but not with brachial or regional stiffness variations. Most of the arterial parameters-BP slopes did not show significant differences when considering a variation in z-cSBP and z-pSBP. z-CEM and z-FEM were mainly associated with z-cPP and z-pPP variations, respectively. Disregard of age and sex, the variations in arterial parameters associated with BP interindividual variations showed differences depending on whether variations were central or peripheral; in SBP, DBP or PP and depending on the arterial segment considered.

  7. The Discoloration effect of White Mineral Trioxide Aggregate (WMTA), Calcium Enriched Mixture (CEM), and Portland Cement (PC) on Human Teeth.

    PubMed

    Salem-Milani, Amin; Ghasemi, Saeede; Rahimi, Saeed; Ardalan-Abdollahi, Amir; Asghari-Jafarabadi, Mohammad

    2017-12-01

    The aim of this study was to evaluate the discoloration induced by CEM cement, Portland cement (PC) and MTA mixed with propylene glycol (MTA-PG) in comparison to White MTA. Ninety extracted premolar and canine teeth were resected 2 mm below the CEJ. The coronal part of crown was prepared with peeso reamer and Gates-Glidden drills, and the specimens were randomly divided into 4 experimental (n=20) and one control (n=10) groups. The tooth crowns in experimental groups 1 to 4 were filled with White MTA, PC, CEM cement and MTA-PG, respectively; and in group 5, the teeth were kept empty. After incubation, digital photographs of teeth were acquired at 4 time points (before, immediately after placing the materials, 3 and 6 months afterwards). Images were transferred to Adobe Photoshop CS4 and CIE L*a*b color space was used for tooth shade assessment. One-Way ANOVA and One-Sample t-test were used to compare discoloration of teeth between groups. Significant statistical discoloration was only observed in the cervical one third of all groups at each time points (except between 3 and 6 months). Tooth discoloration was greatest in PC and lower in MTA and MTA-PG at the end of 6 months. The tooth discoloration between immediately and 3 months after placing the materials had significant difference only between MTA and PC; and also the tooth discoloration between immediately and 6 months after placing the materials was observed only between PC and MTA, and PC and MTA-PG. All of the experimental biomaterials caused tooth discoloration after 6 months, of those, PC had the most and MTA and MTA-PG had the least discoloration effect. Key words: Mineral trioxide aggregate (MTA). Calcium enriched mixture (CEM). Propylene glycol. Portland cement.

  8. A comparative study on sealing ability of mineral trioxide aggregate, calcium enriched cement and bone cement in furcal perforations.

    PubMed

    Nazari Moghadam, K; Aghili, H; Rashed Mohassel, A; Zahedpasha, S; Moghadamnia, A A

    2014-06-01

    The aim of this study was to compare the bacterial leakage of mineral trioxide aggregate (MTA), calcium enriched cement (CEM), and bone cement (BC) as repair materials in furcal perforations. The pulp chambers of 57 human mandibular molar teeth were accessed and the root canal orifices were located. The roots were horizontally sectioned in the middle third. Composite resin was used to fill the root canal orifices and the apical end of the roots. The 1 mm furcation perforations were performed in the center of the pulp chamber floor, using diamond fissure burs. Fifty one teeth were divided into 3 groups. Six teeth were used as controls. Perforation defects were repaired with either MTA, CEM, or BC. A bacterial leakage model utilizing phenol red with 3% lactose broth was used for evaluation. The upper pulp chambers were subsequently filled with 5μL bacterial suspension containing Enterococcus faecalis. Then the top of the assembly was covered with aluminum foil to avoid unintentional contamination. The entire apparatus was incubated at 37°C, and bacterial leakage was evaluated daily by checking the turbidity in the culture medium of the lower part of the chamber. The bacterial inoculation was renewed every day, for 30 days. Leakage was noted when color conversion of the culture media was observed and was statistically analyzed using the Chi-square test with significance set at P< 0.05. Sixteen (94%) of the 17 samples of the MTA group, thirteen (81%) of the 17 samples of the CEM group and sixteen (94%) of the 17 samples in BC group were fully contaminated at 30 days. There was no statistically significant difference between the three study groups (P>0.05). According to the present study, in teeth with furcation perforations, the coronal seal produced by MTA preparations was equally to that produced by CEM cement and Bone cement.

  9. Biochemical characterization and anti-inflammatory properties of an isothiocyanate-enriched moringa (Moringa oleifera) seed extract.

    PubMed

    Jaja-Chimedza, Asha; Graf, Brittany L; Simmler, Charlotte; Kim, Youjin; Kuhn, Peter; Pauli, Guido F; Raskin, Ilya

    2017-01-01

    Moringa oleifera Lam. is a tropical plant, used for centuries as food and traditional medicine. The aim of this study was to develop, validate and biochemically characterize an isothiocyanate-enriched moringa seed extract (MSE), and to compare the anti-inflammatory effects of MSE-containing moringa isothiocyanate-1 (MIC-1) with a curcuminoid-enriched turmeric extract (CTE), and a material further enriched in its primary phytochemical, curcumin (curcumin-enriched material; CEM). MSE was prepared by incubating ground moringa seeds with water to allow myrosinase-catalyzed enzymatic formation of bioactive MIC-1, the predominant isothiocyanate in moringa seeds. Optimization of the extraction process yielded an extract of 38.9% MIC-1. Phytochemical analysis of MSE revealed the presence of acetylated isothiocyanates, phenolic glycosides unique to moringa, flavonoids, fats and fatty acids, proteins and carbohydrates. MSE showed a reduction in the carrageenan-induced rat paw edema (33% at 500 mg/kg MIC-1) comparable to aspirin (27% at 300 mg/kg), whereas CTE did not have any significant effect. In vitro, MIC-1 at 1 μM significantly reduced the production of nitric oxide (NO) and at 5 μM, the gene expression of LPS-inducible nitric oxide synthase (iNOS) and interleukins 1β and 6 (IL-1β and IL-6), whereas CEM did not show any significant activity at all concentrations tested. MIC-1 (10μM) was also more effective at upregulating the nuclear factor (erythroid-derived 2)-like 2 (Nrf2) target genes NAD(P)H:quinone oxidoreductase 1 (NQO1), glutathione S-transferase pi 1 (GSTP1), and heme oxygenase 1 (HO1) than the CEM. Thus, in contrast to CTE and CEM, MSE and its major isothiocyanate MIC-1 displayed strong anti-inflammatory and antioxidant properties in vivo and in vitro, making them promising botanical leads for the mitigation of inflammatory-mediated chronic disorders.

  10. Biochemical characterization and anti-inflammatory properties of an isothiocyanate-enriched moringa (Moringa oleifera) seed extract

    PubMed Central

    Simmler, Charlotte; Kim, Youjin; Kuhn, Peter; Pauli, Guido F.; Raskin, Ilya

    2017-01-01

    Moringa oleifera Lam. is a tropical plant, used for centuries as food and traditional medicine. The aim of this study was to develop, validate and biochemically characterize an isothiocyanate-enriched moringa seed extract (MSE), and to compare the anti-inflammatory effects of MSE-containing moringa isothiocyanate-1 (MIC-1) with a curcuminoid-enriched turmeric extract (CTE), and a material further enriched in its primary phytochemical, curcumin (curcumin-enriched material; CEM). MSE was prepared by incubating ground moringa seeds with water to allow myrosinase-catalyzed enzymatic formation of bioactive MIC-1, the predominant isothiocyanate in moringa seeds. Optimization of the extraction process yielded an extract of 38.9% MIC-1. Phytochemical analysis of MSE revealed the presence of acetylated isothiocyanates, phenolic glycosides unique to moringa, flavonoids, fats and fatty acids, proteins and carbohydrates. MSE showed a reduction in the carrageenan-induced rat paw edema (33% at 500 mg/kg MIC-1) comparable to aspirin (27% at 300 mg/kg), whereas CTE did not have any significant effect. In vitro, MIC-1 at 1 μM significantly reduced the production of nitric oxide (NO) and at 5 μM, the gene expression of LPS-inducible nitric oxide synthase (iNOS) and interleukins 1β and 6 (IL-1β and IL-6), whereas CEM did not show any significant activity at all concentrations tested. MIC-1 (10μM) was also more effective at upregulating the nuclear factor (erythroid-derived 2)-like 2 (Nrf2) target genes NAD(P)H:quinone oxidoreductase 1 (NQO1), glutathione S-transferase pi 1 (GSTP1), and heme oxygenase 1 (HO1) than the CEM. Thus, in contrast to CTE and CEM, MSE and its major isothiocyanate MIC-1 displayed strong anti-inflammatory and antioxidant properties in vivo and in vitro, making them promising botanical leads for the mitigation of inflammatory-mediated chronic disorders. PMID:28792522

  11. 3,3′-Diindolylmethane Induces G1 Arrest and Apoptosis in Human Acute T-Cell Lymphoblastic Leukemia Cells

    PubMed Central

    Shorey, Lyndsey E.; Hagman, Amanda M.; Williams, David E.; Ho, Emily; Dashwood, Roderick H.; Benninghoff, Abby D.

    2012-01-01

    Certain bioactive food components, including indole-3-carbinol (I3C) and 3,3′-diindolylmethane (DIM) from cruciferous vegetables, have been shown to target cellular pathways regulating carcinogenesis. Previously, our laboratory showed that dietary I3C is an effective transplacental chemopreventive agent in a dibenzo[def,p]chrysene (DBC)-dependent model of murine T-cell lymphoblastic lymphoma. The primary objective of the present study was to extend our chemoprevention studies in mice to an analogous human neoplasm in cell culture. Therefore, we tested the hypothesis that I3C or DIM may be chemotherapeutic in human T-cell acute lymphoblastic leukemia (T-ALL) cells. Treatment of the T-ALL cell lines CCRF-CEM, CCRF-HSB2, SUP-T1 and Jurkat with DIM in vitro significantly reduced cell proliferation and viability at concentrations 8- to 25-fold lower than the parent compound I3C. DIM (7.5 µM) arrested CEM and HSB2 cells at the G1 phase of the cell cycle and 15 µM DIM significantly increased the percentage of apoptotic cells in all T-ALL lines. In CEM cells, DIM reduced protein expression of cyclin dependent kinases 4 and 6 (CDK4, CDK6) and D-type cyclin 3 (CCND3); DIM also significantly altered expression of eight transcripts related to human apoptosis (BCL2L10, CD40LG, HRK, TNF, TNFRSF1A, TNFRSF25, TNFSF8, TRAF4). Similar anticancer effects of DIM were observed in vivo. Dietary exposure to 100 ppm DIM significantly decreased the rate of growth of human CEM xenografts in immunodeficient SCID mice, reduced final tumor size by 44% and increased the apoptotic index compared to control-fed mice. Taken together, our results demonstrate a potential for therapeutic application of DIM in T-ALL. PMID:22514694

  12. Analysis of heparin oligosaccharides by capillary electrophoresis-negative-ion electrospray ionization mass spectrometry.

    PubMed

    Lin, Lei; Liu, Xinyue; Zhang, Fuming; Chi, Lianli; Amster, I Jonathan; Leach, Franklyn E; Xia, Qiangwei; Linhardt, Robert J

    2017-01-01

    Most hyphenated analytical approaches that rely on liquid chromatography-MS require relatively long separation times, produce incomplete resolution of oligosaccharide mixtures, use eluents that are incompatible with electrospray ionization, or require oligosaccharide derivatization. Here we demonstrate the analysis of heparin oligosaccharides, including disaccharides, ultralow molecular weight heparin, and a low molecular weight heparin, using a novel electrokinetic pump-based CE-MS coupling eletrospray ion source. Reverse polarity CE separation and negative-mode electrospray ionization were optimized using a volatile methanolic ammonium acetate electrolyte and sheath fluid. The online CE hyphenated negative-ion electrospray ionization MS on an LTQ Orbitrap mass spectrometer was useful in disaccharide compositional analysis and bottom-up and top-down analysis of low molecular weight heparin. The application of this CE-MS method to ultralow molecular heparin suggests that a charge state distribution and the low level of sulfate group loss that is achieved make this method useful for online tandem MS analysis of heparins. Graphical abstract Most hyphenated analytical approaches that rely on liquid chromatography-MS require relatively long separation times, produce incomplete resolution of oligosaccharide mixtures, use eluents that are incompatible with electrospray ionization, or require oligosaccharide derivatization. Here we demonstrate the analysis of heparin oligosaccharides, including disaccharides, ultralow molecular weight heparin, and a low molecular weight heparin, using a novel electrokinetic pump-based CE-MS coupling eletrospray ion source. Reverse polarity CE separation and negative-mode electrospray ionization were optimized using a volatile methanolic ammonium acetate electrolyte and sheath fluid. The online CE hyphenated negative-ion electrospray ionization MS on an LTQ Orbitrap mass spectrometer was useful in disaccharide compositional analysis and bottom-up and top-down analysis of low molecular weight heparin. The application of this CE-MS method to ultralow molecular heparin suggests that a charge state distribution and the low level of sulfate group loss that is achieved make this method useful for online tandem MS analysis of heparins.

  13. Cytotoxicity and modes of action of four Cameroonian dietary spices ethno-medically used to treat cancers: Echinops giganteus, Xylopia aethiopica, Imperata cylindrica and Piper capense.

    PubMed

    Kuete, Victor; Sandjo, Louis P; Wiench, Benjamin; Efferth, Thomas

    2013-08-26

    Echinops giganteus, Imperata cylindrica, Piper capense and Xylopia aethiopica are four medicinal spices used in Cameroon to treat cancers. The above plants previously displayed cytotoxicity against leukemia CCRF-CEM and CEM/ADR5000 cell lines as well as human pancreatic MiaPaCa-2 cells. The present study aims at emphasizing the study of the cytotoxicity and the modes of action of the above plants on a panel of ten cancer cell lines including various sensitive and drug-resistant phenotypes. The study has been extended to the isolation of the bioactive constituents from Echinops giganteus. The cytotoxicity of the extracts was determined using a resazurin reduction assay, whereas the caspase-Glo assay was used to detect the activation of caspases 3/7, caspase 8 and caspase 9 in cells treated with the four extracts. Flow cytometry was used for cell cycle analysis and detection of apoptotic cells, analysis of mitochondrial membrane potential (MMP) as well as measurement of reactive oxygen species (ROS). The four tested extracts inhibited the proliferation of all tested cancer cell lines including sensitive and drug-resistant phenotypes. Collateral sensitivity of cancer cells to the extract of Echinops giganteus was generally better than to doxorubicin. The recorded IC50 ranges were 3.29 µg/mL [against human knockout clones HCT116 (p53(-/-)) colon cancer cells] to 14.32 µg/mL (against human liver hepatocellular carcinoma HepG2 cells) for the crude extract from Echinops giganteus, 4.17 µg/mL (against breast cancer cells transduced with control vector MDA-MB231 cells) to 19.45 µg/mL (against MDA-MB-231 BCRP cells) for that of Piper capense, 4.11 µg/mL (against leukemia CCRF-CEM cells) to 30.60 µg/mL (against leukemia HL60AR cells) for Xylopia aethiopica, 3.28 µg/mL [against HCT116 (p53(-/-)) cells] to 33.43 µg/mL (against HepG2 cells) for Imperata cylindica and 0.11 µg/mL (against CCRF-CEM cells) to 132.47 µg/mL (against HL60AR cells) for doxorubicin. The four tested extracts induced apoptosis in CCRF-CEM cells via the alteration loss of MMP whilst that of Piper capense also enhanced the production of ROS. The studied plants are potential cytotoxic drugs that deserve more detailed exploration in the future, to develop novel anticancer drugs against sensitive and otherwise drug-resistant phenotypes. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  14. Scalable High Performance Computing: Direct and Large-Eddy Turbulent Flow Simulations Using Massively Parallel Computers

    NASA Technical Reports Server (NTRS)

    Morgan, Philip E.

    2004-01-01

    This final report contains reports of research related to the tasks "Scalable High Performance Computing: Direct and Lark-Eddy Turbulent FLow Simulations Using Massively Parallel Computers" and "Devleop High-Performance Time-Domain Computational Electromagnetics Capability for RCS Prediction, Wave Propagation in Dispersive Media, and Dual-Use Applications. The discussion of Scalable High Performance Computing reports on three objectives: validate, access scalability, and apply two parallel flow solvers for three-dimensional Navier-Stokes flows; develop and validate a high-order parallel solver for Direct Numerical Simulations (DNS) and Large Eddy Simulation (LES) problems; and Investigate and develop a high-order Reynolds averaged Navier-Stokes turbulence model. The discussion of High-Performance Time-Domain Computational Electromagnetics reports on five objectives: enhancement of an electromagnetics code (CHARGE) to be able to effectively model antenna problems; utilize lessons learned in high-order/spectral solution of swirling 3D jets to apply to solving electromagnetics project; transition a high-order fluids code, FDL3DI, to be able to solve Maxwell's Equations using compact-differencing; develop and demonstrate improved radiation absorbing boundary conditions for high-order CEM; and extend high-order CEM solver to address variable material properties. The report also contains a review of work done by the systems engineer.

  15. Design and Development of a Clinical Risk Management Tool Using Radio Frequency Identification (RFID)

    PubMed Central

    Pourasghar, Faramarz; Tabrizi, Jafar Sadegh; Yarifard, Khadijeh

    2016-01-01

    Background: Patient safety is one of the most important elements of quality of healthcare. It means preventing any harm to the patients during medical care process. Objective: This paper introduces a cost-effective tool in which the Radio Frequency Identification (RFID) technology is used to identify medical errors in hospital. Methods: The proposed clinical error management system (CEMS) is consisted of a reader device, a transfer/receiver device, a database and managing software. The reader device works using radio waves and is wireless. The reader sends and receives data to/from the database via the transfer/receiver device which is connected to the computer via USB port. The database contains data about patients’ medication orders. Results: The CEMS has the ability to identify the clinical errors before they occur and then warns the care-giver with voice and visual messages to prevent the error. This device reduces the errors and thus improves the patient safety. Conclusion: A new tool including software and hardware was developed in this study. Application of this tool in clinical settings can help the nurses prevent medical errors. It can also be a useful tool for clinical risk management. Using this device can improve the patient safety to a considerable extent and thus improve the quality of healthcare. PMID:27147802

  16. Design and Development of a Clinical Risk Management Tool Using Radio Frequency Identification (RFID).

    PubMed

    Pourasghar, Faramarz; Tabrizi, Jafar Sadegh; Yarifard, Khadijeh

    2016-04-01

    Patient safety is one of the most important elements of quality of healthcare. It means preventing any harm to the patients during medical care process. This paper introduces a cost-effective tool in which the Radio Frequency Identification (RFID) technology is used to identify medical errors in hospital. The proposed clinical error management system (CEMS) is consisted of a reader device, a transfer/receiver device, a database and managing software. The reader device works using radio waves and is wireless. The reader sends and receives data to/from the database via the transfer/receiver device which is connected to the computer via USB port. The database contains data about patients' medication orders. The CEMS has the ability to identify the clinical errors before they occur and then warns the care-giver with voice and visual messages to prevent the error. This device reduces the errors and thus improves the patient safety. A new tool including software and hardware was developed in this study. Application of this tool in clinical settings can help the nurses prevent medical errors. It can also be a useful tool for clinical risk management. Using this device can improve the patient safety to a considerable extent and thus improve the quality of healthcare.

  17. [Treatment of acrylate wastewater by electrocatalytic reduction process].

    PubMed

    Yu, Li-Na; Song, Yu-Dong; Zhou, Yue-Xi; Zhu, Shu-Quan; Zheng, Sheng-Zhi; Ll, Si-Min

    2011-10-01

    High-concentration acrylate wastewater was treated by an electrocatalytic reduction process. The effects of the cation exchange membrane (CEM) and cathode materials on acrylate reduction were investigated. It indicated that the acrylate could be reduced to propionate acid efficiently by the electrocatalytic reduction process. The addition of CEM to separator with the cathode and anode could significantly improve current efficiency. The cathode materials had significant effect on the reduction of acrylate. The current efficiency by Pd/Nickel foam, was greater than 90%, while those by nickel foam, the carbon fibers and the stainless steel decreased successively. Toxicity of the wastewater decreased considerably and methane production rate in the biochemical methane potential (BMP) test increased greatly after the electrocatalytic reduction process.

  18. Results of the freeze resistance test, swelling index and coefficient of permeability of finegrained mining waste reinforced with cements

    NASA Astrophysics Data System (ADS)

    Morman, Justyna

    2018-04-01

    The article presents the result of laboratory tests for mining waste with grain size of 0 to 2 mm stabilized with cement. Used for stabilization of cement CEM I 42.5 R and blast furnace cement CEM III / A 42.5N - LH / HSR / NA and a plasticizer sealant. Cement was added to the mining waste test in the proportions of 5 - 8% in relation to the skeleton's weight. For the cemented samples, the freeze resistance test, swelling index, coefficient of permeability and pH of water leachate were tested. The addition of a cement binder resulted in diminishing the water permeability of mining waste and limiting the leaching of fine particles from the material.

  19. A preliminary evaluation of an F100 engine parameter estimation process using flight data

    NASA Technical Reports Server (NTRS)

    Maine, Trindel A.; Gilyard, Glenn B.; Lambert, Heather H.

    1990-01-01

    The parameter estimation algorithm developed for the F100 engine is described. The algorithm is a two-step process. The first step consists of a Kalman filter estimation of five deterioration parameters, which model the off-nominal behavior of the engine during flight. The second step is based on a simplified steady-state model of the compact engine model (CEM). In this step, the control vector in the CEM is augmented by the deterioration parameters estimated in the first step. The results of an evaluation made using flight data from the F-15 aircraft are presented, indicating that the algorithm can provide reasonable estimates of engine variables for an advanced propulsion control law development.

  20. A preliminary evaluation of an F100 engine parameter estimation process using flight data

    NASA Technical Reports Server (NTRS)

    Maine, Trindel A.; Gilyard, Glenn B.; Lambert, Heather H.

    1990-01-01

    The parameter estimation algorithm developed for the F100 engine is described. The algorithm is a two-step process. The first step consists of a Kalman filter estimation of five deterioration parameters, which model the off-nominal behavior of the engine during flight. The second step is based on a simplified steady-state model of the 'compact engine model' (CEM). In this step the control vector in the CEM is augmented by the deterioration parameters estimated in the first step. The results of an evaluation made using flight data from the F-15 aircraft are presented, indicating that the algorithm can provide reasonable estimates of engine variables for an advanced propulsion-control-law development.

  1. Design and development of a fast ion mass spectrometer

    NASA Technical Reports Server (NTRS)

    Burch, J. L.

    1983-01-01

    Two Fast Ion Mass Spectrometers (FIMS A and FIMS B) were developed. The design, development, construction, calibration, integration, and flight of these instruments, along with early results from the data analysis efforts are summarized. A medium energy ion mass spectrometer that covers mass velocity space with significantly higher time resolution, improved mass resolution, (particularly for heavier ions), and wider energy range than existing instruments had achieved was completed. The initial design consisted of a dual channel cylindrical electrostatic analyzer followed by a dual channel cylindrical velocity filter. The gain versus count rate characteristics of the high current channel electron multipliers (CEM's), which were chosen for ion detection, revealed a systematic behavior that can be used as a criterion for selection of CEM's for long counting lifetimes.

  2. Vital pulp therapy using calcium-enriched mixture: An evidence-based review

    PubMed Central

    Asgary, Saeed; Ahmadyar, Maryam

    2013-01-01

    Worldwide, casecontrol studies have revealed that the treatment outcomes of root canal therapy (RCT) are generally favorable; however, the overall epidemiological success rate of RCT in the general population is relatively low. On the other hand, vitality of dental pulp is a key factor in the long-term prognosis of permanent teeth; in recent years, vital pulp therapy (VPT) has received significant consideration as it has been revealed that the inflamed pulp has the potential to heal. In this review article, the current best evidence with regard to VPT using calcium-enriched mixture (CEM) cement in human permanent/primary teeth is discussed. A strategy based on a search using keywords for CEM cement as well as VPT was applied. PMID:23716958

  3. Diagnosis of Cell Death by Means of Infrared Spectroscopy

    PubMed Central

    Zelig, Udi; Kapelushnik, Joseph; Moreh, Raymond; Mordechai, Shaul; Nathan, Ilana

    2009-01-01

    Abstract Fourier transform infrared (FTIR) spectroscopy has been established as a fast spectroscopic method for biochemical analysis of cells and tissues. In this research we aimed to investigate FTIR's utility for identifying and characterizing different modes of cell death, using leukemic cell lines as a model system. CCRF-CEM and U937 leukemia cells were treated with arabinoside and doxorubicin apoptosis inducers, as well as with potassium cyanide, saponin, freezing-thawing, and H2O2 necrosis inducers. Cell death mode was determined by various gold standard biochemical methods in parallel with FTIR-microscope measurements. Both cell death modes exhibit large spectral changes in lipid absorbance during apoptosis and necrosis; however, these changes are similar and thus cannot be used to distinguish apoptosis from necrosis. In contrast to the above confounding factor, our results reveal that apoptosis and necrosis can still be distinguished by the degree of DNA opaqueness to infrared light. Moreover, these two cell death modes also can be differentiated by their infrared absorbance, which relates to the secondary structure of total cellular protein. In light of these findings, we conclude that, because of its capacity to monitor multiple biomolecular parameters, FTIR spectroscopy enables unambiguous and easy analysis of cell death modes and may be useful for biochemical and medical applications. PMID:19804743

  4. Assessing the Greenhouse Gas Emissions from Natural Gas Fired Power Plants

    NASA Astrophysics Data System (ADS)

    Hajny, K. D.; Shepson, P. B.; Rudek, J.; Stirm, B. H.; Kaeser, R.; Stuff, A. A.

    2017-12-01

    Natural gas is often discussed as a "bridge fuel" to transition to renewable energy as it only produces 51% the amount of CO2 per unit energy as coal. This, coupled with rapid increases in production fueled by technological advances, has led to a near tripling of natural gas used for electricity generation since 2005. One concern with this idea of a "bridge fuel" is that methane, the primary component of natural gas, is itself a potent greenhouse gas with 28 and 84 times the global warming potential of CO2 based on mass over a 100 and 20 year period, respectively. Studies have estimated that leaks from the point of extraction to end use of 3.2% would offset the climate benefits of natural gas. Previous work from our group saw that 3 combined cycle power plants emitted unburned CH4 from the stacks and leaked additional CH4 from equipment on site, but total loss rates were still less than 2.2%. Using Purdue's Airborne Laboratory for Atmospheric Research (ALAR) we completed additional aircraft based mass balance experiments combined with passes directly over power plant stacks to expand on the previous study. In this work, we have measured at 12 additional natural gas fired power plants including a mix of operation types (baseload, peaking, intermediate) and firing methods (combined cycle, simple thermal, combustion turbine). We have also returned to the 3 plants previously sampled to reinvestigate emissions for each of those, to assess reproducibility of the results. Here we report the comparison of reported continuous emissions monitoring systems (CEMS) data for CO2 to our emission rates calculated from mass balance experiments, as well as a comparison of calculated CH4 emission rates to estimated emission rates based on the EPA emission factor of 1 g CH4/mmbtu natural gas and CEMS reported heat input. We will also discuss emissions from a coal-fired plant which has been sampled by the group in the past and has since converted to natural gas. Lastly, we discuss the ratio of CH4 to CO2 in stack based emissions as it relates to our calculated emission rates and as compared to the same ratio for the emission factors.

  5. Effect of different mixing methods on the bacterial microleakage of calcium-enriched mixture cement.

    PubMed

    Shahi, Shahriar; Jeddi Khajeh, Soniya; Rahimi, Saeed; Yavari, Hamid R; Jafari, Farnaz; Samiei, Mohammad; Ghasemi, Negin; Milani, Amin S

    2016-10-01

    Calcium-enriched mixture (CEM) cement is used in the field of endodontics. It is similar to mineral trioxide aggregate in its main ingredients. The present study investigated the effect of different mixing methods on the bacterial microleakage of CEM cement. A total of 55 human single-rooted human permanent teeth were decoronated so that 14-mm-long samples were obtained and obturated with AH26 sealer and gutta-percha using lateral condensation technique. Three millimeters of the root end were cut off and randomly divided into 3 groups of 15 each (3 mixing methods of amalgamator, ultrasonic and conventional) and 2 negative and positive control groups (each containing 5 samples). BHI (brain-heart infusion agar) suspension containing Enterococcus faecalis was used for bacterial leakage assessment. Statistical analysis was carried out using descriptive statistics, Kaplan-Meier survival analysis with censored data and log rank test. Statistical significance was set at P<0.05. The survival means for conventional, amalgamator and ultrasonic methods were 62.13±12.44, 68.87±12.79 and 77.53±12.52 days, respectively. The log rank test showed no significant differences between the groups. Based on the results of the present study it can be concluded that different mixing methods had no significant effect on the bacterial microleakage of CEM cement.

  6. Mössbauer and X-ray Diffraction Investigations of Sn-containing Binary and Ternary Electrodeposited Alloys from a Gluconate Bath

    NASA Astrophysics Data System (ADS)

    Kuzmann, E.; Stichleutner, S.; Doyle, O.; Chisholm, C. U.; El-Sharif, M.; Homonnay, Z.; Vértes, A.

    2005-04-01

    Constant current technique was applied to electrodeposit tin-containing coatings such as tin-cobalt (Sn-Co), tin-iron (Sn-Fe) and a novel tin-cobalt-iron (Sn-Co-Fe) from a gluconate bath. The effect of plating parameters (current density, deposition time at an electrolyte temperature of 60°C and pH=7.0) on phase composition, crystal structure and magnetic anisotropy of alloy deposits has been investigated mainly by 57Fe CEMS, 119Sn CEMS and transmission Mössbauer Spectroscopy as well as XRD. 57Fe and 119Sn CEM spectra and XRD reflect that the dominant phases of the deposits are orthorhombic Co3Sn2, tetragonal FeSn2 or amorphous Fe-Sn and amorphous Sn-Co-Fe in Sn-Co, Sn-Fe and Sn-Co-Fe coatings, respectively. Furthermore, the relative area of the 2nd and 5th lines of the sextets representing the magnetic iron containing phases decreases continuously with increasing current density in all Fe-containing deposits. At the same time, no essential change in the magnetic anisotropy can be found with the plating time. 119Sn spectra reveal the presence of small amount of β-Sn besides the main phases in Sn-Fe and in the Sn-Co coatings. Magnetically split 119Sn spectra reflecting transferred hyperfine field were observed in the case of Co-Sn-Fe coatings.

  7. Treatment Outcomes of Full Pulpotomy as an Alternative to Tooth Extraction in Molars with Hyperplastic/Irreversible Pulpitis: A Case Report

    PubMed Central

    Asgary, Saeed; Verma, Prashant; Nosrat, Ali

    2017-01-01

    Root canal therapy (RCT) is a common and successful treatment for irreversible pulpitis due to carious pulp exposure in mature permanent teeth. However, it is often an expensive procedure, may require multiple appointments, and requires a high level of training and clinical skill, specifically in molars. Uninsured patients, low-income patients, and patients with limited access to specialist care often elect for extraction of restorable teeth with irreversible pulpitis. There is a need for an alternative affordable treatment option to preserve their teeth and maintain chewing function. A case of pulpotomy using calcium-enriched mixture (CEM) cement in two maxillary molars (#14 and 15) in a healthy 36-year-old patient is presented. Both teeth were diagnosed with symptomatic hyperplastic/irreversible pulpitis. Patient did not have dental insurance, was unable to afford RCT, and refused to extract the teeth. CEM pulpotomy and amalgam build-ups were done as an alternative to extraction. At 2-year recall, both teeth were functional with no signs/symptoms of inflammation/infection. Periapical radiographs and 3D images showed normal PDL around all roots. Pulpotomy with CEM biomaterial might be a viable alternative to tooth extraction for mature permanent teeth with hyperplastic/irreversible pulpitis, and can result in long-term tooth retention and improved oral health. PMID:28512498

  8. Iron silicide formation at different layers of (Fe/Si)3 multilayered structures determined by conversion electron Mössbauer spectroscopy

    NASA Astrophysics Data System (ADS)

    Badía-Romano, L.; Rubín, J.; Magén, C.; Bürgler, D. E.; Bartolomé, J.

    2014-07-01

    The morphology and the quantitative composition of the Fe-Si interface layer forming at each Fe layer of a (Fe/Si)3 multilayer have been determined by means of conversion electron Mössbauer spectroscopy (CEMS) and high-resolution transmission electron microscopy (HRTEM). For the CEMS measurements, each layer was selected by depositing the Mössbauer active 57Fe isotope with 95% enrichment. Samples with Fe layers of nominal thickness dFe = 2.6 nm and Si spacers of dSi = 1.5 nm were prepared by thermal evaporation onto a GaAs(001) substrate with an intermediate Ag(001) buffer layer. HRTEM images showed that Si layers grow amorphous and the epitaxial growth of the Fe is good only for the first deposited layer. The CEMS spectra show that at all Fe/Si and Si/Fe interfaces a paramagnetic c-Fe1-xSi phase is formed, which contains 16% of the nominal Fe deposited in the Fe layer. The bottom Fe layer, which is in contact with the Ag buffer, also contains α-Fe and an Fe1-xSix alloy that cannot be attributed to a single phase. In contrast, the other two layers only comprise an Fe1-xSix alloy with a Si concentration of ≃0.15, but no α-Fe.

  9. Glucocorticoids and Polyamine Inhibitors Synergize to Kill Human Leukemic CEM Cells1

    PubMed Central

    Miller, Aaron L; Johnson, Betty H; Medh, Rheem D; Townsend, Courtney M; Thompson, E Brad

    2002-01-01

    Abstract Glucocorticoids are well-known apoptotic agents in certain classes of lymphoid cell malignancies. Reduction of intracellular polyamine levels by use of inhibitors that block polyamine synthesis slows or inhibits growth of many cells in vitro. Several such inhibitors have shown efficacy in clinical trials, though the toxicity of some compounds has limited their usefulness. We have tested the effects of combinations of the glucocorticoid dexamethasone (Dex) and two polyamine inhibitors, difluoromethylornithine (DFMO) and methyl glyoxal bis guanylhydrazone (MGBG), on the clonal line of human acute lymphoblastic leukemia cells, CEM-C7-14. Dex alone kills these cells, though only after a delay of at least 24 hours. We also evaluated a partially glucocorticoid-resistant c-Myc-expressing CEM-C7-14 clone. We show that Dex downregulates ornithine decarboxylase (ODC), the rate-limiting enzyme in polyamine synthesis. Pretreatment with the ODC inhibitor DFMO, followed by addition of Dex, enhances steroid-evoked kill slightly. The combination of pretreatment with sublethal concentrations of both DFMO and the inhibitor of S-adenosylmethionine decarboxylase, MGBG, followed by addition of Dex, results in strong synergistic cell kill. Both the rapidity and extent of cell kill are enhanced compared to the effects of Dex alone. These results suggest that use of such combinations in vivo may result in apoptosis of malignant cells with lower overall toxicity. PMID:11922393

  10. Quantum cascade laser-based screening portal for the detection of explosive precursors

    NASA Astrophysics Data System (ADS)

    Lindley, Ruth; Normand, Erwan; Howieson, Iain; McCulloch, Michael; Black, Paul; Lewis, Colin; Foulger, Brian

    2007-10-01

    In recent years, quantum cascade lasers (QCL) have been proven in robust, high-performance gas analyzers designed for continuous emission monitoring (CEM) in harsh environments. In 2006, Cascade Technologies reported progress towards adapting its patented technology for homeland security applications by publishing initial results on explosive compound detection. This paper presents the performance and results from a QCL-based people screening portal developed during the past year and aimed at the detection of precursors used in the make up of improvised explosive devices (IED). System tests have been carried out on a large number of potential interferents, together with target precursor materials, reinforcing original assumptions that compound fingerprinting can be effectively demonstrated using this technique. Results have shown that an extremely high degree of specificity can be achieved with a sub-second response time. Furthermore, it has been shown that unambiguous precursor signature recognition can be extended to compound mixtures associated with the intermediate stages in the make up of IEDs, whilst maintaining interferent immunity. The portal sensitivity was configured for parts per billion (ppb) detection level thresholds, but is currently being reconfigured for sub-ppb detection. In summary, the results obtained from the QCL based portal indicate that development of a low cost detection system, with enhanced features such as low false positive and high throughput screening of individuals or items, is possible. Development and testing was carried out with the support of the UK government.

  11. 40 CFR 63.2182 - What records must I keep?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Standards for Hazardous Air Pollutants: Manufacturing of Nutritional Yeast Notification, Reports, and...) Fermentation stage for which you are using the fermenter. (3) Unique CEMS equipment identification number. ...

  12. Indirect resin composite restorations bonded to dentin using self-adhesive resin cements applied with an electric current-assisted method.

    PubMed

    Gotti, Valeria Bisinoto; Feitosa, Victor Pinheiro; Sauro, Salvatore; Correr-Sobrinho, Lourenço; Correr, Americo Bortolazzo

    2014-10-01

    To evaluate the effects of an electric current-assisted application on the bond strength and interfacial morphology of self-adhesive resin cements bonded to dentin. Indirect resin composite build-ups were luted to prepared dentin surfaces using two self-adhesive resin cements (RelyX Unicem and BisCem) and an ElectroBond device under 0, 20, or 40 μA electrical current. All specimens were submitted to microtensile bond strength test and to interfacial SEM analysis. The electric current-assisted application induced no change (P > 0.05) on the overall bond strength, although RelyX Unicem showed significantly higher bond strength (P < 0.05) than BisCem. Similarly, no differences were observed in terms of interfacial integrity when using the electrical current applicator.

  13. Virtual Habitat -a dynamic simulation of closed life support systems -human model status

    NASA Astrophysics Data System (ADS)

    Markus Czupalla, M. Sc.; Zhukov, Anton; Hwang, Su-Au; Schnaitmann, Jonas

    In order to optimize Life Support Systems on a system level, stability questions must be in-vestigated. To do so the exploration group of the Technical University of Munich (TUM) is developing the "Virtual Habitat" (V-HAB) dynamic LSS simulation software. V-HAB shall provide the possibility to conduct dynamic simulations of entire mission scenarios for any given LSS configuration. The Virtual Habitat simulation tool consists of four main modules: • Closed Environment Module (CEM) -monitoring of compounds in a closed environment • Crew Module (CM) -dynamic human simulation • P/C Systems Module (PCSM) -dynamic P/C subsystems • Plant Module (PM) -dynamic plant simulation The core module of the simulation is the dynamic and environment sensitive human module. Introduced in its basic version in 2008, the human module has been significantly updated since, increasing its capabilities and maturity significantly. In this paper three newly added human model subsystems (thermal regulation, digestion and schedule controller) are introduced touching also on the human stress subsystem which is cur-rently under development. Upon the introduction of these new subsystems, the integration of these into the overall V-HAB human model is discussed, highlighting the impact on the most important I/F. The overall human model capabilities shall further be summarized and presented based on meaningful test cases. In addition to the presentation of the results, the correlation strategy for the Virtual Habitat human model shall be introduced assessing the models current confidence level and giving an outlook on the future correlation strategy. Last but not least, the remaining V-HAB mod-ules shall be introduced shortly showing how the human model is integrated into the overall simulation.

  14. Building an Ontology for Identity Resolution in Healthcare and Public Health.

    PubMed

    Duncan, Jeffrey; Eilbeck, Karen; Narus, Scott P; Clyde, Stephen; Thornton, Sidney; Staes, Catherine

    2015-01-01

    Integration of disparate information from electronic health records, clinical data warehouses, birth certificate registries and other public health information systems offers great potential for clinical care, public health practice, and research. Such integration, however, depends on correctly matching patient-specific records using demographic identifiers. Without standards for these identifiers, record linkage is complicated by issues of structural and semantic heterogeneity. Our objectives were to develop and validate an ontology to: 1) identify components of identity and events subsequent to birth that result in creation, change, or sharing of identity information; 2) develop an ontology to facilitate data integration from multiple healthcare and public health sources; and 3) validate the ontology's ability to model identity-changing events over time. We interviewed domain experts in area hospitals and public health programs and developed process models describing the creation and transmission of identity information among various organizations for activities subsequent to a birth event. We searched for existing relevant ontologies. We validated the content of our ontology with simulated identity information conforming to scenarios identified in our process models. We chose the Simple Event Model (SEM) to describe events in early childhood and integrated the Clinical Element Model (CEM) for demographic information. We demonstrated the ability of the combined SEM-CEM ontology to model identity events over time. The use of an ontology can overcome issues of semantic and syntactic heterogeneity to facilitate record linkage.

  15. Cytotoxicity of South-African medicinal plants towards sensitive and multidrug-resistant cancer cells.

    PubMed

    Saeed, Mohamed E M; Meyer, Marion; Hussein, Ahmed; Efferth, Thomas

    2016-06-20

    Traditional medicine plays a major role for primary health care worldwide. Cancer belongs to the leading disease burden in industrialized and developing countries. Successful cancer therapy is hampered by the development of resistance towards established anticancer drugs. In the present study, we investigated the cytotoxicity of 29 extracts from 26 medicinal plants of South-Africa against leukemia cell lines, most of which are used traditionally to treat cancer and related symptoms. We have investigated the plant extracts for their cytotoxic activity towards drug-sensitive parental CCRF-CEM leukemia cells and their multidrug-resistant P-glycoprotein-overexpressing subline, CEM/ADR5000 by means of the resazurin assay. A panel of 60 NCI tumor cell lines have been investigated for correlations between selected phytochemicals from medicinal plants and the expression of resistance-conferring genes (ABC-transporters, oncogenes, tumor suppressor genes). Seven extracts inhibited both cell lines (Acokanthera oppositifolia, Hypoestes aristata, Laurus nobilis, Leonotis leonurus, Plectranthus barbatus, Plectranthus ciliates, Salvia apiana). CEM/ADR5000 cells exhibited a low degree of cross-resistance (3.35-fold) towards the L. leonurus extract, while no cross-resistance was observed to other plant extracts, although CEM/ADR5000 cells were highly resistant to clinically established drugs. The log10IC50 values for two out of 14 selected phytochemicals from these plants (acovenoside A and ouabain) of 60 tumor cell lines were correlated to the expression of ABC-transporters (ABCB1, ABCB5, ABCC1, ABCG2), oncogenes (EGFR, RAS) and tumor suppressors (TP53). Sensitivity or resistance of the cell lines were not statistically associated with the expression of these genes, indicating that multidrug-resistant, refractory tumors expressing these genes may still respond to acovenoside A and ouabain. The bioactivity of South African medicinal plants may represent a basis for the development of strategies to treat multidrug-resistant tumors either by phytotherapeutic approaches with whole plant preparations or by classical drug development with isolated compounds such as acovenoside A or ouabain. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  16. Kefir induces cell-cycle arrest and apoptosis in HTLV-1-negative malignant T-lymphocytes

    PubMed Central

    Maalouf, Katia; Baydoun, Elias; Rizk, Sandra

    2011-01-01

    Background: Adult lymphoblastic leukemia (ALL) is a malignancy that occurs in white blood cells. The overall cure rate in children is 85%, whereas it is only 40% in adults. Kefir is an important probiotic that contains many bioactive ingredients, which give it unique health benefits. It has been shown to control several cellular types of cancer. Purpose: The present study investigates the effect of a cell-free fraction of kefir on CEM and Jurkat cells, which are human T-lymphotropic virus type I (HTLV-1)-negative malignant T-lymphocytes. Methods: Cells were incubated with different kefir concentrations. The cytotoxicity of the compound was evaluated by determining the percentage viability of cells. The effect of all the noncytotoxic concentrations of kefir on the proliferation of CEM and Jurkat cells was then assessed. The levels of transforming growth factor-alpha (TGF-α), transforming growth factor- beta1 (TGF-β1), matrix metalloproteinase-2 (MMP-2), and MMP-9 mRNA upon kefir treatment were then analyzed using reverse transcriptase polymerase chain reaction (RT-PCR). Finally, the growth inhibitory effects of kefir on cell-cycle progression/apoptosis were assessed by Cell Death Detection (ELISA) and flow cytometry. Results: The maximum cytotoxicity recorded after 48-hours treatment with 80 μg/μL kefir was only 42% and 39% in CEM and Jurkat cells, respectively. The percent reduction in proliferation was very significant, and was dose-, and time-dependent. In both cell lines, kefir exhibited its antiproliferative effect by downregulating TGF-α and upregulating TGF-β1 mRNA expression. Upon kefir treatment, a marked increase in cell-cycle distribution was noted in the preG1 phase of CEM and Jurkat cells, indicating the proapoptotic effect of kefir, which was further confirmed by Cell Death Detection ELISA. However, kefir did not affect the mRNA expression of metalloproteinases needed for the invasion of leukemic cell lines. Conclusion: In conclusion, kefir is effective in inhibiting proliferation and inducing apoptosis of HTLV-1-negative malignant T-lymphocytes. Therefore, further in vivo investigation is highly recommended. PMID:21448298

  17. Integrating data from randomized controlled trials and observational studies to predict the response to pregabalin in patients with painful diabetic peripheral neuropathy.

    PubMed

    Alexander, Joe; Edwards, Roger A; Savoldelli, Alberto; Manca, Luigi; Grugni, Roberto; Emir, Birol; Whalen, Ed; Watt, Stephen; Brodsky, Marina; Parsons, Bruce

    2017-07-20

    More patient-specific medical care is expected as more is learned about variations in patient responses to medical treatments. Analytical tools enable insights by linking treatment responses from different types of studies, such as randomized controlled trials (RCTs) and observational studies. Given the importance of evidence from both types of studies, our goal was to integrate these types of data into a single predictive platform to help predict response to pregabalin in individual patients with painful diabetic peripheral neuropathy (pDPN). We utilized three pivotal RCTs of pregabalin (398 North American patients) and the largest observational study of pregabalin (3159 German patients). We implemented a hierarchical cluster analysis to identify patient clusters in the Observational Study to which RCT patients could be matched using the coarsened exact matching (CEM) technique, thereby creating a matched dataset. We then developed autoregressive moving average models (ARMAXs) to estimate weekly pain scores for pregabalin-treated patients in each cluster in the matched dataset using the maximum likelihood method. Finally, we validated ARMAX models using Observational Study patients who had not matched with RCT patients, using t tests between observed and predicted pain scores. Cluster analysis yielded six clusters (287-777 patients each) with the following clustering variables: gender, age, pDPN duration, body mass index, depression history, pregabalin monotherapy, prior gabapentin use, baseline pain score, and baseline sleep interference. CEM yielded 1528 unique patients in the matched dataset. The reduction in global imbalance scores for the clusters after adding the RCT patients (ranging from 6 to 63% depending on the cluster) demonstrated that the process reduced the bias of covariates in five of the six clusters. ARMAX models of pain score performed well (R 2 : 0.85-0.91; root mean square errors: 0.53-0.57). t tests did not show differences between observed and predicted pain scores in the 1955 patients who had not matched with RCT patients. The combination of cluster analyses, CEM, and ARMAX modeling enabled strong predictive capabilities with respect to pain scores. Integrating RCT and Observational Study data using CEM enabled effective use of Observational Study data to predict patient responses.

  18. Effectiveness of alternative rail passenger equipment crashworthiness strategies

    DOT National Transportation Integrated Search

    2006-04-04

    Crashworthiness strategies, which include crash energy : management (CEM), pushback couplers, and push/pull : operation, are evaluated and compared under specific collision : conditions. Comparisons of three strategies are evaluated in : this paper: ...

  19. Presidential Green Chemistry Challenge: 2009 Greener Reaction Conditions Award

    EPA Pesticide Factsheets

    Presidential Green Chemistry Challenge 2009 award winner, CEM Corporation, developed a fast, automated analytical process using less toxic reagents and less energy to distinguish protein from the food adulterant, melamine.

  20. Analysis of Halogen-Mercury Reactions in Flue Gas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paula Buitrago; Geoffrey Silcox; Constance Senior

    2010-01-01

    Oxidized mercury species may be formed in combustion systems through gas-phase reactions between elemental mercury and halogens, such as chorine or bromine. This study examines how bromine species affect mercury oxidation in the gas phase and examines the effects of mixtures of bromine and chlorine on extents of oxidation. Experiments were conducted in a bench-scale, laminar flow, methane-fired (300 W), quartz-lined reactor in which gas composition (HCl, HBr, NO{sub x}, SO{sub 2}) and temperature profile were varied. In the experiments, the post-combustion gases were quenched from flame temperatures to about 350 C, and then speciated mercury was measured using amore » wet conditioning system and continuous emissions monitor (CEM). Supporting kinetic calculations were performed and compared with measured levels of oxidation. A significant portion of this report is devoted to sample conditioning as part of the mercury analysis system. In combustion systems with significant amounts of Br{sub 2} in the flue gas, the impinger solutions used to speciate mercury may be biased and care must be taken in interpreting mercury oxidation results. The stannous chloride solution used in the CEM conditioning system to convert all mercury to total mercury did not provide complete conversion of oxidized mercury to elemental, when bromine was added to the combustion system, resulting in a low bias for the total mercury measurement. The use of a hydroxylamine hydrochloride and sodium hydroxide solution instead of stannous chloride showed a significant improvement in the measurement of total mercury. Bromine was shown to be much more effective in the post-flame, homogeneous oxidation of mercury than chlorine, on an equivalent molar basis. Addition of NO to the flame (up to 400 ppmv) had no impact on mercury oxidation by chlorine or bromine. Addition of SO{sub 2} had no effect on mercury oxidation by chlorine at SO{sub 2} concentrations below about 400 ppmv; some increase in mercury oxidation was observed at SO{sub 2} concentrations of 400 ppmv and higher. In contrast, SO{sub 2} concentrations as low as 50 ppmv significantly reduced mercury oxidation by bromine, this reduction could be due to both gas and liquid phase interactions between SO{sub 2} and oxidized mercury species. The simultaneous presence of chlorine and bromine in the flue gas resulted in a slight increase in mercury oxidation above that obtained with bromine alone, the extent of the observed increase is proportional to the chlorine concentration. The results of this study can be used to understand the relative importance of gas-phase mercury oxidation by bromine and chlorine in combustion systems. Two temperature profiles were tested: a low quench (210 K/s) and a high quench (440 K/s). For chlorine the effects of quench rate were slight and hard to characterize with confidence. Oxidation with bromine proved sensitive to quench rate with significantly more oxidation at the lower rate. The data generated in this program are the first homogeneous laboratory-scale data on bromine-induced oxidation of mercury in a combustion system. Five Hg-Cl and three Hg-Br mechanisms, some published and others under development, were evaluated and compared to the new data. The Hg-halogen mechanisms were combined with submechanisms from Reaction Engineering International for NO{sub x}, SO{sub x}, and hydrocarbons. The homogeneous kinetics under-predicted the levels of mercury oxidation observed in full-scale systems. This shortcoming can be corrected by including heterogeneous kinetics in the model calculations.« less

  1. Recognition of chemical entities: combining dictionary-based and grammar-based approaches.

    PubMed

    Akhondi, Saber A; Hettne, Kristina M; van der Horst, Eelke; van Mulligen, Erik M; Kors, Jan A

    2015-01-01

    The past decade has seen an upsurge in the number of publications in chemistry. The ever-swelling volume of available documents makes it increasingly hard to extract relevant new information from such unstructured texts. The BioCreative CHEMDNER challenge invites the development of systems for the automatic recognition of chemicals in text (CEM task) and for ranking the recognized compounds at the document level (CDI task). We investigated an ensemble approach where dictionary-based named entity recognition is used along with grammar-based recognizers to extract compounds from text. We assessed the performance of ten different commercial and publicly available lexical resources using an open source indexing system (Peregrine), in combination with three different chemical compound recognizers and a set of regular expressions to recognize chemical database identifiers. The effect of different stop-word lists, case-sensitivity matching, and use of chunking information was also investigated. We focused on lexical resources that provide chemical structure information. To rank the different compounds found in a text, we used a term confidence score based on the normalized ratio of the term frequencies in chemical and non-chemical journals. The use of stop-word lists greatly improved the performance of the dictionary-based recognition, but there was no additional benefit from using chunking information. A combination of ChEBI and HMDB as lexical resources, the LeadMine tool for grammar-based recognition, and the regular expressions, outperformed any of the individual systems. On the test set, the F-scores were 77.8% (recall 71.2%, precision 85.8%) for the CEM task and 77.6% (recall 71.7%, precision 84.6%) for the CDI task. Missed terms were mainly due to tokenization issues, poor recognition of formulas, and term conjunctions. We developed an ensemble system that combines dictionary-based and grammar-based approaches for chemical named entity recognition, outperforming any of the individual systems that we considered. The system is able to provide structure information for most of the compounds that are found. Improved tokenization and better recognition of specific entity types is likely to further improve system performance.

  2. Recognition of chemical entities: combining dictionary-based and grammar-based approaches

    PubMed Central

    2015-01-01

    Background The past decade has seen an upsurge in the number of publications in chemistry. The ever-swelling volume of available documents makes it increasingly hard to extract relevant new information from such unstructured texts. The BioCreative CHEMDNER challenge invites the development of systems for the automatic recognition of chemicals in text (CEM task) and for ranking the recognized compounds at the document level (CDI task). We investigated an ensemble approach where dictionary-based named entity recognition is used along with grammar-based recognizers to extract compounds from text. We assessed the performance of ten different commercial and publicly available lexical resources using an open source indexing system (Peregrine), in combination with three different chemical compound recognizers and a set of regular expressions to recognize chemical database identifiers. The effect of different stop-word lists, case-sensitivity matching, and use of chunking information was also investigated. We focused on lexical resources that provide chemical structure information. To rank the different compounds found in a text, we used a term confidence score based on the normalized ratio of the term frequencies in chemical and non-chemical journals. Results The use of stop-word lists greatly improved the performance of the dictionary-based recognition, but there was no additional benefit from using chunking information. A combination of ChEBI and HMDB as lexical resources, the LeadMine tool for grammar-based recognition, and the regular expressions, outperformed any of the individual systems. On the test set, the F-scores were 77.8% (recall 71.2%, precision 85.8%) for the CEM task and 77.6% (recall 71.7%, precision 84.6%) for the CDI task. Missed terms were mainly due to tokenization issues, poor recognition of formulas, and term conjunctions. Conclusions We developed an ensemble system that combines dictionary-based and grammar-based approaches for chemical named entity recognition, outperforming any of the individual systems that we considered. The system is able to provide structure information for most of the compounds that are found. Improved tokenization and better recognition of specific entity types is likely to further improve system performance. PMID:25810767

  3. Approaches to Estimate Consumer Exposure under TSCA

    EPA Pesticide Factsheets

    CEM contains a combination of models and default parameters which are used to estimate inhalation, dermal, and oral exposures to consumer products and articles for a wide variety of product and article use categories.

  4. 40 CFR Appendix F to Part 60 - Quality Assurance Procedures

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... automatically adjust the data to the corrected calibration values (e.g., microprocessor control) must be... calibration values (e.g., microprocessor control), you must program your PM CEMS to record the unadjusted...

  5. Electromagnetic, magnetic, and gravimetric surveys at the Bi'r Jarbuah gold prospect, Kingdom of Saudi Arabia

    USGS Publications Warehouse

    Miller, C.H.; Showail, A.A.; Bazzari, M.A.; Khoja, J.A.; Hajour, M.O.

    1990-01-01

    A detailed search for gold and associated minerals was begun in the Bi'r Jarbuah area in 1988. Crone electromagnetic (CEM), magnetic, and gravimetric surveys were run in the areas of greatest interest. Anomalous areas are most interesting in the southern part of the area where linear magnetic and gravity anomalies trend east-northeast and overlap in large part. They are most prominent at or near the south end of a diorite pluton where some quartz veins mined by the ancients also trend northeast. A second area, at the extreme southern end of the survey, contains a large CEM anomaly that coincides with northeast-trending magnetic and gravity anomalies. Although this second area is largely overlain by alluvium, a major quartz vein strikes to the northeast in the adjacent bedrock.

  6. In Vitro Activity of Fusidic Acid (CEM-102, Sodium Fusidate) against Staphylococcus aureus Isolates from Cystic Fibrosis Patients and Its Effect on the Activities of Tobramycin and Amikacin against Pseudomonas aeruginosa and Burkholderia cepacia▿

    PubMed Central

    McGhee, Pamela; Clark, Catherine; Credito, Kim; Beachel, Linda; Pankuch, Glenn A.; Appelbaum, Peter C.; Kosowska-Shick, Klaudia

    2011-01-01

    We tested the MICs of fusidic acid (CEM-102) plus other agents against 40 methicillin-resistant Staphylococcus aureus (MRSA) isolates from cystic fibrosis patients and the activities of fusidic acid with or without tobramycin or amikacin against Pseudomonas aeruginosa, MRSA, and Burkholderia cepacia isolates from cystic fibrosis patients in a 24-h time-kill study. Fusidic acid was potent (MICs, 0.125 to 0.5 μg/ml; a single 500-mg dose of fusidic acid at 8 h averaged 8 to 12. 5 μg/ml with 91 to 97% protein binding) against all MRSA strains. No antagonism was observed; synergy occurred for one MRSA strain treated with fusidic acid plus tobramycin. PMID:21343445

  7. In vitro activity of fusidic acid (CEM-102, sodium fusidate) against Staphylococcus aureus isolates from cystic fibrosis patients and its effect on the activities of tobramycin and amikacin against Pseudomonas aeruginosa and Burkholderia cepacia.

    PubMed

    McGhee, Pamela; Clark, Catherine; Credito, Kim; Beachel, Linda; Pankuch, Glenn A; Appelbaum, Peter C; Kosowska-Shick, Klaudia

    2011-05-01

    We tested the MICs of fusidic acid (CEM-102) plus other agents against 40 methicillin-resistant Staphylococcus aureus (MRSA) isolates from cystic fibrosis patients and the activities of fusidic acid with or without tobramycin or amikacin against Pseudomonas aeruginosa, MRSA, and Burkholderia cepacia isolates from cystic fibrosis patients in a 24-h time-kill study. Fusidic acid was potent (MICs, 0.125 to 0.5 μg/ml; a single 500-mg dose of fusidic acid at 8 h averaged 8 to 12. 5 μg/ml with 91 to 97% protein binding) against all MRSA strains. No antagonism was observed; synergy occurred for one MRSA strain treated with fusidic acid plus tobramycin.

  8. Development of loop-mediated isothermal amplification methods for detecting Taylorella equigenitalis and Taylorella asinigenitalis

    PubMed Central

    KINOSHITA, Yuta; NIWA, Hidekazu; KATAYAMA, Yoshinari; HARIU, Kazuhisa

    2015-01-01

    ABSTRACT Taylorella equigenitalis is a causative bacterium of contagious equine metritis (CEM), and Taylorella asinigenitalis is species belonging to genus Taylorella. The authors developed two loop-mediated isothermal amplification (LAMP) methods, Te-LAMP and Ta-LAMP, for detecting T. equigenitalis and T. asinigenitalis, respectively. Using experimentally spiked samples, Te-LAMP was as sensitive as a published semi-nested PCR method, and Ta-LAMP was more sensitive than conventional PCR. Multiplex LAMP worked well without nonspecific reactions, and the analytical sensitivities of multiplex LAMP in the spiked samples were almost equivalent to those of Te-LAMP and Ta-LAMP. Therefore, the LAMP methods are considered useful tools to detect T. equigenitalis and/or T. asinigenitalis, and preventive measures will be rapidly implemented if the occurrence of CEM is confirmed by the LAMP methods. PMID:25829868

  9. Mechanisms of mineral membrane fouling growth modulated by pulsed modes of current during electrodialysis: evidences of water splitting implications in the appearance of the amorphous phases of magnesium hydroxide and calcium carbonate.

    PubMed

    Cifuentes-Araya, Nicolás; Astudillo-Castro, Carolina; Bazinet, Laurent

    2014-07-15

    Experiments revealed the fouling nature evolutions along different electrodialysis (ED) trials, and how it disappears when current pulsation acts repetitively on the interfaces of ion-exchange membranes (IEMs). Fouling was totally controlled on the diluate side of cation-exchange membrane (CEM) by the repetitive pulsation frequency of the higher on-duty ratios applied. They created steady water splitting proton-barriers that neutralized OH(-) leakage through the membrane, decreasing the interfacial pH, and fouling of the concentrate side. The anion-exchange membrane (AEM) on the diluate side was similarly protected, but it was fouled once water splitting OH(-) generation became either intense enough or excessively weak. Interestingly, amorphous magnesium hydroxide (AMH) stemmed on the CEM-diluate side from brucite under intense water splitting OH(-) generation, and/or strong OH(-) leakage electromigration through the membrane. Water dissociation and overlimiting current regimes triggered drastic water molecule removal from crystal lattices through an accelerated cascade water splitting reaction. Also, amorphous calcium carbonate (ACC) appeared on CEM under intense water splitting reaction, and disappeared once intense OH(-) leakage was allowed by the water splitting proton-barrier dissipation. Our findings have implications for membrane fouling control, as well as for the understanding of the growth behavior of CaCO3 and Mg(OH)2 species on electromembrane interfaces. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. [Experimental investigation of laser plasma soft X-ray source with gas target].

    PubMed

    Ni, Qi-liang; Gong, Yan; Lin, Jing-quan; Chen, Bo; Cao, Jian-lin

    2003-02-01

    This paper describes a debris-free laser plasma soft X-ray source with a gas target, which has high operating frequency and can produce strong soft X-ray radiation. The valve of this light source is drived by a piezoelectrical ceramic whose operating frequency is up to 400 Hz. In comparison with laser plasma soft X-ray sources using metal target, the light source is debris-free. And it has higher operating frequency than gas target soft X-ray sources whose nozzle is controlled by a solenoid valve. A channel electron multiplier (CEM) operating in analog mode is used to detect the soft X-ray generated by the laser plasma source, and the CEM's output is fed to to a charge-sensitive preamplifier for further amplification purpose. Output charges from the CEM are proportional to the amplitude of the preamplifier's output voltage. Spectra of CO2, Xe and Kr at 8-14 nm wavelength which can be used for soft X-ray projection lithography are measured. The spectrum for CO2 consists of separate spectral lines originate mainly from the transitions in Li-like and Be-like ions. The Xe spectrum originating mainly from 4d-5f, 4d-4f, 4d-6p and 4d-5p transitions in multiply charged xenon ions. The spectrum for Kr consists of separate spectral lines and continuous broad spectra originating mainly from the transitions in Cu-, Ni-, Co- and Fe-like ions.

  11. Capillary electrophoresis interfaced with a mass spectrometer (CE-MS): technical considerations and applicability for biomarker studies in animals.

    PubMed

    Albalat, Amaya; Husi, Holger; Siwy, Justyna; Nally, Jarlath E; McLauglin, Mark; Eckersall, Peter D; Mullen, William

    2014-02-01

    Proteomics is a growing field that has the potential to be applied to many biology-related disciplines. However, the study of the proteome has proven to be very challenging due to its high level of complexity when compared to genome and transcriptome data. In order to analyse this level of complexity, high resolution separation of peptides/proteins are needed together with high resolution analysers. Currently, liquid chromatography and capillary electrophoresis (CE) are the two most widely used separation techniques that can be coupled on-line with a mass spectrometer (MS). In CE, proteins/ peptides are separated according to their size, charge and shape leading to high resolving power. Although further progress in the area of sensitivity, throughput and proteome coverage are expected, MS-based proteomics have developed to a level at which they are habitually applied to study a wide range of biological questions. The aim of this review is to present CE-MS as a proteomic analytical platform for biomarker research that could be used in farm animal and veterinary studies. This is a MS-analytical platform that has been widely used for biomarker research in the biomedical field but its application in animal proteomic studies is relatively novel. The review will focus on introducing the CE-MS platform and the primary considerations for its application to biomarker research. Furthermore, current applications but more importantly potential application in the field of farm animals and veterinary science will be presented and discussed.

  12. Current Application of Capillary Electrophoresis in Nanomaterial Characterisation and Its Potential to Characterise the Protein and Small Molecule Corona

    PubMed Central

    Guggenheim, Emily J.; Briffa, Sophie M.; Thorn, James A.; Lynch, Iseult; Valsami-Jones, Eugenia

    2018-01-01

    Due to the increasing use and production of nanomaterials (NMs), the ability to characterise their physical/chemical properties quickly and reliably has never been so important. Proper characterisation allows a thorough understanding of the material and its stability, and is critical to establishing dose-response curves to ascertain risks to human and environmental health. Traditionally, methods such as Transmission Electron Microscopy (TEM), Field Flow Fractionation (FFF) and Dynamic Light Scattering (DLS) have been favoured for size characterisation, due to their wide-availability and well-established protocols. Capillary Electrophoresis (CE) offers a faster and more cost-effective solution for complex dispersions including polydisperse or non-spherical NMs. CE has been used to rapidly separate NMs of varying sizes, shapes, surface modifications and compositions. This review will discuss the literature surrounding the CE separation techniques, detection and NM characteristics used for the analysis of a wide range of NMs. The potential of combining CE with mass spectrometry (CE-MS) will also be explored to further expand the characterisation of NMs, including the layer of biomolecules adsorbed to the surface of NMs in biological or environmental compartments, termed the acquired biomolecule corona. CE offers the opportunity to uncover new/poorly characterised low abundance and polar protein classes due to the high ionisation efficiency of CE-MS. Furthermore, the possibility of using CE-MS to characterise the poorly researched small molecule interactions within the NM corona is discussed. PMID:29439415

  13. Natural lignans from Arctium lappa modulate P-glycoprotein efflux function in multidrug resistant cancer cells.

    PubMed

    Su, Shan; Cheng, Xinlai; Wink, Michael

    2015-02-15

    Arctium lappa is a well-known traditional medicinal plant in China (TCM) and Europe that has been used for thousands of years to treat arthritis, baldness or cancer. The plant produces lignans as secondary metabolites which have a wide range of bioactivities. Yet, their ability to reverse multidrug resistance (MDR) in cancer cells has not been explored. In this study, we isolated six lignans from A. lappa seeds, namely arctigenin, matairesinol, arctiin, (iso)lappaol A, lappaol C, and lappaol F. The MDR reversal potential of the isolated lignans and the underlying mechanism of action were studied using two MDR cancer cell lines, CaCo2 and CEM/ADR 5000 which overexpress P-gp and other ABC transporters. In two-drug combinations of lignans with the cytotoxic doxorubicin, all lignans exhibited synergistic effects in CaCo2 cells and matairesinol, arctiin, lappaol C and lappaol F display synergistic activity in CEM/ADR 5000 cells. Additionally, in three-drug combinations of lignans with the saponin digitonin and doxorubicin MDR reversal activity was even stronger enhanced. The lignans can increase the retention of the P-gp substrate rhodamine 123 in CEM/ADR 5000 cells, indicating that lignans can inhibit the activity of P-gp. Our study provides a first insight into the potential chemosensitizing activity of a series of natural lignans, which might be candidates for developing novel adjuvant anticancer agents. Copyright © 2015 Elsevier GmbH. All rights reserved.

  14. Production and characterisation of a novel chicken IgY antibody raised against C-terminal peptide from human thymidine kinase 1.

    PubMed

    Wu, Chuanjing; Yang, Rongjiang; Zhou, Ji; Bao, Shing; Zou, Li; Zhang, Pinggan; Mao, Yongrong; Wu, Jianping; He, Qimin

    2003-06-01

    Egg yolk is a good source of highly specific antibodies against mammalian antigens because of the phylogenetic distance between birds and mammals. Chicken egg yolk immunoglobulins (IgY) were generated to a synthetic 31-amino acid peptide from the C-terminal of human HeLa thymidine kinase 1 (TK1) enzyme. The anti-TK1 IgY antibody was purified using affinity chromatography against the 31-amino acid peptide. The purified antibody inhibited the catalytic activity of the TK1 enzyme in the CEM TK1(+) cells and recognized the 25-kDa subunit and tetrameric form of TK1, which has a pI value of 8.3. No immunoreaction was observed in CEM TK1(-) cells. Western blot of the serum TK1 (S-TK1) also showed that only a single band was found in the serum of patients with malignancies. No band was seen in healthy serum. Furthermore, dot blots and enhanced chemiluminescence (ECL) detection of S-TK1 performed on sera of preoperative patients with gastric cancer (GC) (n=31) and healthy controls (n=62) showed that the levels of S-TK1 in the sera of cancer patients were significantly different (P<0.01). Using ECL dot blots, 0.1 pg of TK1 in 3 microl sera could be detected. Immunohistostaining of tissues in the 11 advanced-stage cancer patients (four breast carcinomas, three hepatocarcinomas and four thyroid carcinomas) indicated that a strong staining of TK1 enzyme was found in the cytoplasm of malignant cells. No staining or weak staining was seen in normal tissues. We suggest that screening for TK1 using anti-TK1 IgY may be potentially useful for serological and immunohistochemical detection of TK1 as an early prognosis and for monitoring patients undergoing treatment.

  15. Improved crashworthiness of rail passenger equipment in the United States

    DOT National Transportation Integrated Search

    2006-06-30

    The Federal Railroad Administration has been conducting research to develop strategies for improved passenger : protection in train accidents. Crash energy management (CEM) has been developed as a strategy for structural : crashworthiness. Interior s...

  16. Methods for open innovation on a genome-design platform associating scientific, commercial, and educational communities in synthetic biology.

    PubMed

    Toyoda, Tetsuro

    2011-01-01

    Synthetic biology requires both engineering efficiency and compliance with safety guidelines and ethics. Focusing on the rational construction of biological systems based on engineering principles, synthetic biology depends on a genome-design platform to explore the combinations of multiple biological components or BIO bricks for quickly producing innovative devices. This chapter explains the differences among various platform models and details a methodology for promoting open innovation within the scope of the statutory exemption of patent laws. The detailed platform adopts a centralized evaluation model (CEM), computer-aided design (CAD) bricks, and a freemium model. It is also important for the platform to support the legal aspects of copyrights as well as patent and safety guidelines because intellectual work including DNA sequences designed rationally by human intelligence is basically copyrightable. An informational platform with high traceability, transparency, auditability, and security is required for copyright proof, safety compliance, and incentive management for open innovation in synthetic biology. GenoCon, which we have organized and explained here, is a competition-styled, open-innovation method involving worldwide participants from scientific, commercial, and educational communities that aims to improve the designs of genomic sequences that confer a desired function on an organism. Using only a Web browser, a participating contributor proposes a design expressed with CAD bricks that generate a relevant DNA sequence, which is then experimentally and intensively evaluated by the GenoCon organizers. The CAD bricks that comprise programs and databases as a Semantic Web are developed, executed, shared, reused, and well stocked on the secure Semantic Web platform called the Scientists' Networking System or SciNetS/SciNeS, based on which a CEM research center for synthetic biology and open innovation should be established. Copyright © 2011 Elsevier Inc. All rights reserved.

  17. Increasing the availability and quality of caesarean section in Tanzania.

    PubMed

    Nyamtema, A; Mwakatundu, N; Dominico, S; Mohamed, H; Shayo, A; Rumanyika, R; Kairuki, C; Nzabuhakwa, C; Issa, O; Lyimo, C; Kasiga, I; van Roosmalen, J

    2016-09-01

    To describe the results of increasing availability and quality of caesarean deliveries and anaesthesia in rural Tanzania. Before-after intervention study design. Rural Tanzania. Ten health centres located in rural areas were upgraded to provide comprehensive emergency obstetric care (CEmOC) and the four related district hospitals were supported. Upgrading entailed constructing and equipping maternity blocks, operation rooms and laboratories; installing solar systems, backup generators and water supply systems. Associate clinicians were trained in anaesthesia and in CEmOC. Mentoring and audit of reasons for caesarean section (CS) and maternal deaths were carried out. Measures of interest were compared using analysis of variance (ANOVA) statistical tests. Trends in CS rates, proportion of unjustified CS, use of spinal anaesthesia, and the risk of death from complications related to CS and anaesthesia. During the audit period (2012-2014), 5868 of 58 751 deliveries were by CS (10%). The proportion of CS considered to be unjustified decreased from 30 to 17% in health centres (P = 0.02) and from 37 to 20% in hospitals (P < 0.001). Practice of spinal anaesthesia for CS increased from 10% to 64% in hospitals (P < 0.001). Of 110 maternal deaths, 18 (16.4%) were associated with complications of CS, giving a risk of 3.1 per 1000 CS; three (2.7%) were judged to be anaesthetic-associated deaths with a risk of 0.5 per 1000 caesarean deliveries. Increasing availability and quality of CS by improving infrastructure, training and audit of reasons for CS is feasible, acceptable and required in low resource settings. Increasing availability and quality of CS in rural Africa is feasible. © 2016 Royal College of Obstetricians and Gynaecologists.

  18. Single ion hit detection set-up for the Zagreb ion microprobe

    NASA Astrophysics Data System (ADS)

    Smith, R. W.; Karlušić, M.; Jakšić, M.

    2012-04-01

    Irradiation of materials by heavy ions accelerated in MV tandem accelerators may lead to the production of latent ion tracks in many insulators and semiconductors. If irradiation is performed in a high resolution microprobe facility, ion tracks can be ordered by submicrometer positioning precision. However, full control of the ion track positioning can only be achieved by a reliable ion hit detection system that should provide a trigger signal irrespectively of the type and thickness of the material being irradiated. The most useful process that can be utilised for this purpose is emission of secondary electrons from the sample surface that follows the ion impact. The status report of the set-up presented here is based on the use of a channel electron multiplier (CEM) detector mounted on an interchangable sample holder that is inserted into the chamber in a close geometry along with the sample to be irradiated. The set-up has been tested at the Zagreb ion microprobe for different ions and energies, as well as different geometrical arrangements. For energies of heavy ions below 1 MeV/amu, results show that efficient (100%) control of ion impact can be achieved only for ions heavier than silicon. The successful use of the set-up is demonstrated by production of ordered single ion tracks in a polycarbonate film and by monitoring fluence during ion microbeam patterning of Foturan glass.

  19. Determination of integral cross sections of 3H in Al foils monitors irradiated by protons with energies ranging from 40 to 2600 MeV

    NASA Astrophysics Data System (ADS)

    Titarenko, Yu. E.; Batyaev, V. F.; Chauzova, M. V.; Chauzova, M. V.; Kashirin, I. A.; Malinovskiy, S. V.; Pavlov, K. V.; Rogov, V. I.; Titarenko, A. Yu.; Zhivun, V. M.; Mashnik, S. G.; Stankovskiy, A. Yu.

    2016-05-01

    The results of 3H production in Al foil monitors (˜ 59 mg/cm2 thickness) are presented. These foils have been irradiated in 15×15 mm polyethylene bags of ˜ 14 mg/cm2 thickness together with foils of Cr (˜ 395 mg/cm2 thickness) and 56Fe (˜ 332 mg/cm2 thickness) by protons of different energies in a range of 0.04 - 2.6 GeV. The diameters of all the foils were 10.5 mm. The irradiations were carried out at the ITEP accelerator U-10 under the ISTC Project # 3266 in 2006-2009. 3H has been extracted from Al foils using an A307 Sample Oxidizer. An ultra low level liquid scintillation spectrometer Quantulus1220 was used to measure the 3H β-spectra and the SpectraDec software package was applied for spectra processing, deconvolution and 3H activity determination. The values of the Al (p, x)3H reaction cross sections obtained in these experiments are compared with data measured at other labs and with results of simulations by the MCNP6 radiation transport code using the CEM03.03 event generator.

  20. Determination of integral cross sections of 3 H in Al foils monitors irradiated by protons with energies ranging from 40 to 2600 MeV

    DOE PAGES

    Titarenko, Yu. E.; Batyaev, V. F.; Chauzova, M. V.; ...

    2016-01-01

    Our results of 3H production in Al foil monitors (~ 59 mg/cm 2 thickness) are presented. We irradiated these foils in 15×15 mm polyethylene bags of ~ 14 mg/cm 2 thickness together with foils of Cr (~ 395 mg/cm 2 thickness) and 56Fe (~ 332 mg/cm 2 thickness) by protons of different energies in a range of 0.04 – 2.6 GeV. The diameters of all the foils were 10.5 mm. The irradiations were carried out at the ITEP accelerator U–10 under the ISTC Project # 3266 in 2006–2009. 3H has been extracted from Al foils using an A307 Sample Oxidizer.more » We then used an ultra low level liquid scintillation spectrometer Quantulus1220 to measure the 3H β–spectra and the SpectraDec software package was applied for spectra processing, deconvolution and 3H activity determination. The values of the Al (p, x) 3H reaction cross sections obtained in these experiments are compared with data measured at other labs and with results of simulations by the MCNP6 radiation transport code using the CEM03.03 event generator.« less

Top