Sample records for monitoring system cgms

  1. [Usefulness of continuous glucose monitoring system (CGMS) in monitoring glycaemic profile in small children with diabetes type 1].

    PubMed

    Głowińska-Olszewska, Barbara; Urban, Mirosława; Peczyńska, Jadwiga; Florys, Bozena; Kowalewski, Marek

    2005-01-01

    Improved methods of diabetes therapy result in a near normoglycaemic state in many patients. This leads however unfortunately to more frequent hypoglycaemic incidents. Particularly small children, whose nervous system is not fully mature, are at high risk of central nervous system damage in case of hypoglycaemia. A new method of detail monitoring of glycaemia provides CGMS system. The aim of the study was to compare the glycaemic profile, with high attention to hypoglycaemia in groups of young and older children with diabetes type 1, using CGMS and routine glucose meter. We studied 32 children with diabetes type 1. Children were divided into groups: group I--small children, n=17 (<7 yrs of age), mean age 5,8 years, with disease duration--2,46 years, with mean HbA1c level--7,22%, and group II--older children, n=15 (>10 years of age), mean age--12 years, with disease duration--3 years, with HbA1c level--7,21%. Continuous glucose monitoring system (CGMS), by MiniMed, was applied in outpatient or hospital conditions, after short training of patient and parents; together with routine glucose meter measurements, 4-8 times/24 hours. In 9 patients from small children group CGMS was repeated after 2 months. Hypoglycaemic incidents detected with CGMS were similar in both groups: 4,6 in I group vs. 4,2 in II group (ns). Hypoglycaemic incidents found with meter were lower in I group--1,6 vs. 2,3 in II group (ns). Mean hypoglycaemic time/24 hour was longer in small children group: 101 min vs. 74 min in group II (p<00,05). In I group we found higher number of hypoglycaemic incidents during the night compared to group II--1,7 vs. 0,8 (p<00,05) and longer duration of night hypoglycaemia: in I group--56 min vs. 32 min in group II (p<00,05). Repeated CGMS study in 9 children from I group revealed decreased mean time of hypoglycaemia/24 hours from 134 min/24 h to 90 min/24 h (p<00,05) and decreased time of night hypoglycaemia from 65 min to 40 min (p<00,05), with a comparable number of hypoglycaemic incidents. Hypoglycaemic incidents found with routine meter measurements in small children were 1,6 vs. 4,6 hypoglycaemia found with CGMS (p<00,05), in the older children group routine measurement found 2,3 hypoglycaemia vs. 4,2 detected with CGMS (ns). 1. CGMS can be particularly usefull in monitoring glucose profile and detecting hypoglycaemia incidents, mainly nocturnal in small children. 2. CGMS allows to verify meal dose of insulin and to decrease postprandial hyperglycaemia. 3. Modification of insulin therapy on the base of CGMS helps to decrease the time of hypoglycaemia and hyperglycemia, particularly during the night.

  2. Parental sleep quality and continuous glucose monitoring system use in children with type 1 diabetes.

    PubMed

    Landau, Z; Rachmiel, M; Pinhas-Hamiel, O; Boaz, M; Bar-Dayan, Y; Wainstein, J; Tauman, R

    2014-01-01

    To compare sleep quality and sleep-wake patterns in parents of children with type 1 diabetes before routine use of the continuous glucose monitoring system (CGMS) and while using it. Thirteen parents completed the Pittsburg Sleep Quality Index (PSQI), a 7-day sleep diary, and wore an actigraph (a wristwatch-size motion detector) during the night for 1 week before pediatric use of CGMS and 4-8 weeks after initiating routine use of the CGMS. Mean age of parents (ten mothers, three fathers) was 39 (range 32-47) years; mean age of children was 9.3 years (range 5.5-16.5 years); mean disease duration was 3.4 (range 0.6-11.2) years. PSQI total score demonstrated similar quality of sleep with and without use of the CGMS (4.6 and 4.9, respectively, p = 0.45). Six of the 13 parents reported severe sleep problems (PSQI ≥ 5) with and without the CGMS. The sleep diary indicated a greater number of awakening episodes during CGMS use than without the CGMS (1.6 and 1, respectively, p = 0.03), and actigraphy documented an increase in the number of wake bouts (22.9 and 19.7, p = 0.03) as well as in total wake time (48.3 and 42.2 min, p = 0.03) during CGMS use as compared with the period prior to CGMS use. Although self-perception of sleep quality remained unchanged, CGMS use appeared to affect actual parental sleep continuity somewhat negatively. This should be made clear to parents who may hold expectations of improvement in sleep quality following initiation of CGMS use.

  3. Clinical assessment of blood glucose homeostasis in horses: comparison of a continuous glucose monitoring system with a combined intravenous glucose and insulin test protocol.

    PubMed

    Johnson, P J; Wiedmeyer, C E; LaCarrubba, A; Messer, N T; Dingfelder, H A; Cogswell, A M; Amorim, J R R; Ganjam, V K

    2011-01-01

    The combined glucose-insulin test (CGIT) is helpful for evaluating insulin sensitivity. A continuous glucose monitoring system (CGMS) reports changes in interstitial glucose concentrations as they occur in the blood. Use of the CGMS minimizes animal contact and may be useful when performing a CGIT. Results obtained using a CGMS are useful for the evaluation of glucose responses during the evaluation of insulin sensitivity in equids. Seven mature, obese ponies. Ponies were equipped with CGMS for determination of interstitial glucose concentrations. Glucose (150 mg/kg, i.v.) and insulin (0.1 U/kg, i.v.) were administered and blood glucose concentrations determined at (minutes after time zero) 1, 5, 15, 25, 35, 45, 60, 75, 90, 105, and 120 with a hand-held glucometer. Blood chemistry results were compared with simultaneously obtained results using CGMS. Concordance coefficients determined for comparison of blood glucose concentrations determined by a hand-held glucometer and those determined by CGMS after the zero time point were 0.623, 0.764, 0.834, 0.854, and 0.818 (for delays of 0, 5, 10, 15, and 20 minutes, respectively). Interstitial glucose concentrations obtained by the CGMS compared favorably to blood glucose concentrations. CGMS may be useful for assessment of glucose dynamics in the CGIT. Copyright © 2010 by the American College of Veterinary Internal Medicine.

  4. Glucose metabolism disorder in obese children assessed by continuous glucose monitoring system.

    PubMed

    Zou, Chao-Chun; Liang, Li; Hong, Fang; Zhao, Zheng-Yan

    2008-02-01

    Continuous glucose monitoring system (CGMS) can measure glucose levels at 5-minute intervals over a few days, and may be used to detect hypoglycemia, guide insulin therapy, and control glucose levels. This study was undertaken to assess the glucose metabolism disorder by CGMS in obese children. Eighty-four obese children were studied. Interstitial fluid (ISF) glucose levels were measured by CGMS for 24 hours covering the time for oral glucose tolerance test (OGTT). Impaired glucose tolerance (IGT), impaired fasting glucose (IFG), type 2 diabetic mellitus (T2DM) and hypoglycemia were assessed by CGMS. Five children failed to complete CGMS test. The glucose levels in ISF measured by CGMS were highly correlated with those in capillary samples (r=0.775, P<0.001). However, the correlation between ISF and capillary glucose levels was lower during the first hour than that in the later time period (r=0.722 vs r=0.830), and the ISF glucose levels in 69.62% of children were higher than baseline levels in the initial 1-3 hours. In 79 obese children who finished the CGMS, 2 children had IFG, 2 had IGT, 3 had IFG + IGT, and 2 had T2DM. Nocturnal hypoglycemia was noted during the overnight fasting in 11 children (13.92%). Our data suggest that glucose metabolism disorder including hyperglycemia and hypoglycemia is very common in obese children. Further studies are required to improve the precision of the CGMS in children.

  5. Use of the continuous glucose monitoring system in Goettingen Minipigs, with a special focus on the evaluation of insulin-dependent diabetes.

    PubMed

    Strauss, A; Tiurbe, C; Chodnevskaja, I; Thiede, A; Timm, S; Ulrichs, K; Moskalenko, V

    2008-03-01

    Adult pig islet isolation has greatly improved in the past few years. Islet grafts may now be tested in large animals. Continuous Glucose Monitoring System (CGMS) was applied to diabetic Goettingen Minipigs (GMP) to improve the management of hyperglycemia and hypoglycemia and their welfare before transplantation. GMP (25-35 kg) received a minipig diet once daily. Diabetes was induced by streptozotocin (STZ; 150 mg/kg intravenous [IV]; n = 5) or by surgical pancreatectomy (PGMP; n = 3). Interstitial glucose concentration (IGC) was monitored continuously with an implanted sensor; CGMS was calibrated using conventional blood glucose tests 3-4 times per day; CGMS data were fed into the monitor memory and analyzed using CGMS software. Glucose sensors were handled accurately. Diabetes occurred 2-3 days after STZ or immediately after pancreatectomy with basal C-peptide secretion of <0.4 ng/mL (measured using intravenous glucose tolerance test) and prompt loss of body weight. Insulin substitution was necessary to keep the GMP in good condition for up to 5-6 months, with stable body weight and normal behavior. Some GMP became hypoglycemic, which was only documented by CGMS, but not by conventional glucose assays. Tight glucose control and substitution of exocrine enzymes (Creon 25,000 E/d) reduced morbidity of the PGMP, which was then comparable with that of STZ-GMP. The CGMS, developed for humans, is equally suitable for the 2 GMP diabetes models. Close-meshed glucose monitoring and insulin treatment improved the general condition of the diabetic GMP, ie, the islet graft recipients, and will thus greatly add to posttransplantation success.

  6. Accuracy of a real-time continuous glucose monitoring system in children with septic shock: A pilot study.

    PubMed

    Prabhudesai, Sumant; Kanjani, Amruta; Bhagat, Isha; Ravikumar, Karnam G; Ramachandran, Bala

    2015-11-01

    The aim of this prospective, observational study was to determine the accuracy of a real-time continuous glucose monitoring system (CGMS) in children with septic shock. Children aged 30 days to 18 years admitted to the Pediatric Intensive Care Unit with septic shock were included. A real-time CGMS sensor was used to obtain interstitial glucose readings. CGMS readings were compared statistically with simultaneous laboratory blood glucose (BG). Nineteen children were included, and 235 pairs of BG-CGMS readings were obtained. BG and CGMS had a correlation coefficient of 0.61 (P < 0.001) and a median relative absolute difference of 17.29%. On Clarke's error grid analysis, 222 (94.5%) readings were in the clinically acceptable zones (A and B). When BG was < 70, 70-180, and > 180 mg/dL, 44%, 100%, and 76.9% readings were in zones A and B, respectively (P < 0.001). The accuracy of CGMS was not affected by the presence of edema, acidosis, vasopressors, steroids, or renal replacement therapy. On receiver operating characteristics curve analysis, a CGMS reading <97 mg/dL predicted hypoglycemia (sensitivity 85.2%, specificity 75%, area under the curve [AUC] =0.85). A reading > 141 mg/dL predicted hyperglycemia (sensitivity 84.6%, specificity 89.6%, AUC = 0.87). CGMS provides a fairly, accurate estimate of BG in children with septic shock. It is unaffected by a variety of clinical variables. The accuracy over extremes of blood sugar may be a concern. We recommend larger studies to evaluate its use for the early detection of hypoglycemia and hyperglycemia.

  7. Accuracy of a continuous glucose monitoring system in dogs and cats with diabetic ketoacidosis.

    PubMed

    Reineke, Erica L; Fletcher, Daniel J; King, Lesley G; Drobatz, Kenneth J

    2010-06-01

    (1) To determine the ability of a continuous interstitial glucose monitoring system (CGMS) to accurately estimate blood glucose (BG) in dogs and cats with diabetic ketoacidosis. (2) To determine the effect of perfusion, hydration, body condition score, severity of ketosis, and frequency of calibration on the accuracy of the CGMS. Prospective study. University Teaching Hospital. Thirteen dogs and 11 cats diagnosed with diabetic ketoacidosis were enrolled in the study within 24 hours of presentation. Once BG dropped below 22.2 mmol/L (400 mg/dL), a sterile flexible glucose sensor was placed aseptically in the interstitial space and attached to the continuous glucose monitoring device for estimation of the interstitial glucose every 5 minutes. BG measurements were taken with a portable BG meter every 2-4 hours at the discretion of the primary clinician and compared with CGMS glucose measurements. The CGMS estimates of BG and BG measured on the glucometer were strongly associated regardless of calibration frequency (calibration every 8 h: r=0.86, P<0.001; calibration every 12 h: r=0.85, P<0.001). Evaluation of this data using both the Clarke and Consensus error grids showed that 96.7% and 99% of the CGMS readings, respectively, were deemed clinically acceptable (Zones A and B errors). Interpatient variability in the accuracy of the CGMS glucose measurements was found but was not associated with body condition, perfusion, or degree of ketosis. A weak association between hydration status of the patient as assessed with the visual analog scale and absolute percent error (Spearman's rank correlation, rho=-0.079, 95% CI=-0.15 to -0.01, P=0.03) was found, with the device being more accurate in the more hydrated patients. The CGMS provides clinically accurate estimates of BG in patients with diabetic ketoacidosis.

  8. Real-Time Continuous Glucose Monitoring Reduces the Duration of Hypoglycemia Episodes: A Randomized Trial in Very Low Birth Weight Neonates

    PubMed Central

    Uettwiller, Florence; Chemin, Aude; Bonnemaison, Elisabeth; Favrais, Géraldine; Saliba, Elie; Labarthe, François

    2015-01-01

    Objectives Hypoglycemia is frequent in very low birth weight (VLBW) neonates and compromises their neurological outcome. The aim of this study was to compare real-time continuous glucose monitoring system (RT-CGMS) to standard methods by intermittent capillary blood glucose testing in detecting and managing hypoglycemia. Study design Forty-eight VLBW neonates were enrolled in this prospective study. During their 3 first days of life, their glucose level was monitored either by RT-CGMS (CGM-group), or by intermittent capillary glucose testing (IGM-group) associated with a blind-CGMS to detect retrospectively missed hypoglycemia. Outcomes were the number and duration of hypoglycemic (≤50mg/dl) episodes per patient detected by CGMS. Results Forty-three monitorings were analyzed (IGM n = 21, CGM n = 22), with a median recording time of 72 hours. In the IGM group, blind-CGMS revealed a significantly higher number of hypoglycemia episodes than capillary blood glucose testing (1.2±0.4 vs 0.4±0.2 episode/patient, p<0.01). In the CGM-group, the use of RT-CGMS made it possible (i) to detect the same number of hypoglycemia episodes as blind-CGMS (1.2±0.4 episode/patient), (ii) to adapt the glucose supply in neonates with hypoglycemia (increased supply during days 1 and 2), and (iii) to significantly reduce the duration of hypoglycemia episodes per patient (CGM 44[10–140] min versus IGM 95[15–520] min, p<0.05). Furthermore, it reduced the number of blood samples (CGM 16.9±1.0 vs IGM 21.9±1.0 blood sample/patient, p<0.001). Conclusion RT-CGMS played a beneficial role in managing hypoglycemia in VLBW neonates by adjusting the carbohydrate supply to the individual needs and by reducing the duration of hypoglycemia episodes. The clinical significance of the biological differences observed in our study need to be explored. PMID:25590334

  9. Continuous glucose monitoring system in the screening of early glucose derangements in children and adolescents with cystic fibrosis.

    PubMed

    Franzese, Adriana; Valerio, Giuliana; Buono, Pietro; Spagnuolo, Maria Immacolata; Sepe, Angela; Mozzillo, Enza; De Simone, Ilaria; Raia, Valeria

    2008-02-01

    In cystic fibrosis (CF), diabetes mellitus (DM) is associated with progression of pulmonary disease and nutritional impairment. To compare oral glucose tolerance test (OGTT) and continuous glucose monitoring system (CGMS) in patients with CF with early glucose derangements. Thirty-two patients with CF (5-20 years) with intermediate glucose values > 7.7 mmol/l during OGTT received a CGMS registration. Patients were classified into those with normal glucose tolerance (NGT), impaired glucose tolerance (IGT) and DM, according to glucose values at 120 min of OGTT and during CGMS. Furthermore BMI z-scores, forced expiratory volume in 1 second (FEV1%), number of respiratory infections/year, enzyme supplementation, and HbA1c were evaluated. OGTT and CGMS derangements were in agreement in 43.7% of the patients. BMI z-scores, FEV1%, number of respiratory infections/ year, enzyme supplementation, and HbA1c did not differ among the three groups. HbA1c, correlated positively with 120 min OGTT (r = 0.34; p = 0.059), CGMS area (r = 0.35; p = 0.048) and the number of respiratory infections, and negatively with FEV1%. Intermediate glucose values during OGTT should be considered as a screening test in patients with CF. CGMS can be useful in studying the early occurrence of glucose derangements in selected patients.

  10. Comparison of glucose fluctuations between day- and night-time measured using a continuous glucose monitoring system in diabetic dogs.

    PubMed

    Mori, Akihiro; Kurishima, Miyuki; Oda, Hitomi; Saeki, Kaori; Arai, Toshiro; Sako, Toshinori

    2013-01-31

    Monitoring of blood glucose concentration is important to evaluate the diabetic status of dogs. Continuous glucose monitoring systems (CGMS) have been applied in veterinary medicine for glucose monitoring in diabetic dogs. The purpose of the study was to evaluate the daily glycemic profiles obtained with CGMS and compare glucose fluctuations between day- and night-time in diabetic dogs. Five diabetic dogs were used in this study and were treated with either NPH insulin or insulin detemir. For data analyses, day-time was defined as 9:00 am-9:00 pm and night-time as 9:00 pm-9:00 am. Using glucose profiles, we determined the mean glucose concentrations (1- and 12-hr intervals), and times spent in hyperglycemia >200 mg/dl or hypoglycemia <60 mg/dl. None of the parameters differed significantly between day-time and night-time in dogs treated with NPH insulin or insulin detemir. In conclusion, this study confirmed, using CGMS, that there are no differences in glucose fluctuations between day- and night-time, in diabetic dogs on a similar feeding regimen and insulin administration.

  11. Continuous glucose monitoring system in the operating room and intensive care unit: any difference according to measurement sites?

    PubMed

    Song, In-Kyung; Lee, Ji-Hyun; Kang, Joo-Eun; Park, Yang-Hyo; Kim, Hee-Soo; Kim, Jin-Tae

    2017-02-01

    Given the benefit of glucose control in the perioperative period, we evaluated the accuracy and performance of the continuous glucose monitoring system (CGMS) depending on different measurement sites in the operating room (OR) and in the intensive care unit (ICU). Patients over 18 years of age scheduled for elective surgery and ICU admission were enrolled prospectively. Two CGMS sensors were inserted into the subcutaneous tissue of the proximal lateral thigh and the lateral abdomen. The rate of successful measurements from thigh and abdomen in the OR and in the ICU were calculated separately. Each CGMS values were compared with the time-matched arterial blood glucose measurements. CGMS values from both measurement sites were also compared. A total of 22 patients undergoing cardiac surgeries were studied. The rate of successful measurements was higher in the ICU (73.2 %) than in the OR (66.0 %) (P = 0.01); however, that from thigh (72.9 %) and from abdomen (58.7 %) showed statistically significant difference only in the OR (P = 0.04). The Pearson correlation coefficient of thigh and abdomen versus arterial values was 0.67 and 0.60, respectively (P < 0.001). In Clarke error grid analysis, 94.6 % (89.3 % in the OR and 96.1 % in the ICU) of values from thigh fell into clinically acceptable zones compared to 93.7 % (89.0 % in the OR and 95.4 % in the ICU) from abdomen. There were no statistically significant differences in the accuracy according to measurement sites. The CGMS showed high measurement failure rate, especially in the OR. In the OR, the rate of successful measurement was higher from thigh than from abdomen. The CGMS showed low accuracy compared to arterial reference values. Nevertheless, there was no difference in the accuracy of the CGMS between two measurement sites. Perioperative performance of the CGMS still needs to be improved considering relatively low successful measurement rates.

  12. Validation of the continuous glucose monitoring sensor in preterm infants.

    PubMed

    Beardsall, K; Vanhaesebrouck, S; Ogilvy-Stuart, A L; Vanhole, C; VanWeissenbruch, M; Midgley, P; Thio, M; Cornette, L; Ossuetta, I; Palmer, C R; Iglesias, I; de Jong, M; Gill, B; de Zegher, F; Dunger, D B

    2013-03-01

    Recent studies have highlighted the need for improved methods of monitoring glucose control in intensive care to reduce hyperglycaemia, without increasing the risk of hypoglycaemia. Continuous glucose monitoring is increasingly used in children with diabetes, but there are little data regarding its use in the preterm infant, particularly at extremes of glucose levels and over prolonged periods. This study aimed to assess the accuracy of the continuous glucose monitoring sensor (CGMS) across the glucose profile, and to determine whether there was any deterioration over a 7 day period. Prospectively collected CGMS data from the NIRTURE Trial was compared with the data obtained simultaneously using point of care glucose monitors. An international multicentre randomised controlled trial. One hundred and eighty-eight very low birth weight control infants. Optimal accuracy, performance goals (American Diabetes Association consensus), Bland Altman, Error Grid analyses and accuracy. The mean (SD) duration of CGMS recordings was 156.18 (29) h (6.5 days), with a total of 5207 paired glucose levels. CGMS data correlated well with point of care devices (r=0.94), with minimal bias. It met the Clarke Error Grid and Consensus Grid criteria for clinical significance. Accuracy of single readings to detect set thresholds of hypoglycaemia, or hyperglycaemia was poor. There was no deterioration over time from insertion. CGMS can provide information on trends in glucose control, and guidance on the need for blood glucose assessment. This highlights the potential use of CGMS in optimising glucose control in preterm infants.

  13. Hypoglycemia alarm enhancement using data fusion.

    PubMed

    Skladnev, Victor N; Tarnavskii, Stanislav; McGregor, Thomas; Ghevondian, Nejhdeh; Gourlay, Steve; Jones, Timothy W

    2010-01-01

    The acceptance of closed-loop blood glucose (BG) control using continuous glucose monitoring systems (CGMS) is likely to improve with enhanced performance of their integral hypoglycemia alarms. This article presents an in silico analysis (based on clinical data) of a modeled CGMS alarm system with trained thresholds on type 1 diabetes mellitus (T1DM) patients that is augmented by sensor fusion from a prototype hypoglycemia alarm system (HypoMon). This prototype alarm system is based on largely independent autonomic nervous system (ANS) response features. Alarm performance was modeled using overnight BG profiles recorded previously on 98 T1DM volunteers. These data included the corresponding ANS response features detected by HypoMon (AiMedics Pty. Ltd.) systems. CGMS data and alarms were simulated by applying a probabilistic model to these overnight BG profiles. The probabilistic model developed used a mean response delay of 7.1 minutes, measurement error offsets on each sample of +/- standard deviation (SD) = 4.5 mg/dl (0.25 mmol/liter), and vertical shifts (calibration offsets) of +/- SD = 19.8 mg/dl (1.1 mmol/liter). Modeling produced 90 to 100 simulated measurements per patient. Alarm systems for all analyses were optimized on a training set of 46 patients and evaluated on the test set of 56 patients. The split between the sets was based on enrollment dates. Optimization was based on detection accuracy but not time to detection for these analyses. The contribution of this form of data fusion to hypoglycemia alarm performance was evaluated by comparing the performance of the trained CGMS and fused data algorithms on the test set under the same evaluation conditions. The simulated addition of HypoMon data produced an improvement in CGMS hypoglycemia alarm performance of 10% at equal specificity. Sensitivity improved from 87% (CGMS as stand-alone measurement) to 97% for the enhanced alarm system. Specificity was maintained constant at 85%. Positive predictive values on the test set improved from 61 to 66% with negative predictive values improving from 96 to 99%. These enhancements were stable within sensitivity analyses. Sensitivity analyses also suggested larger performance increases at lower CGMS alarm performance levels. Autonomic nervous system response features provide complementary information suitable for fusion with CGMS data to enhance nocturnal hypoglycemia alarms. 2010 Diabetes Technology Society.

  14. Hypoglycemia in Type 2 Diabetes--More Common Than You Think: A Continuous Glucose Monitoring Study.

    PubMed

    Gehlaut, Richa Redhu; Dogbey, Godwin Y; Schwartz, Frank L; Marling, Cynthia R; Shubrook, Jay H

    2015-04-27

    Hypoglycemia is often the limiting factor for intensive glucose control in diabetes management, however its actual prevalence in type 2 diabetes (T2DM) is not well documented. A total of 108 patients with T2DM wore a continuous glucose monitoring system (CGMS) for 5 days. Rates and patterns of hypoglycemia and glycemic variability (GV) were calculated. Patient and medication factors were correlated with rates, timing, and severity of hypoglycemia. Of the patients, 49.1% had at least 1 hypoglycemic episode (mean 1.74 episodes/patient/ 5 days of CGMS) and 75% of those patients experienced at least 1 asymptomatic hypoglycemic episode. There was no significant difference in the frequency of daytime versus nocturnal hypoglycemia. Hypoglycemia was more frequent in individuals on insulin (alone or in combination) (P = .02) and those on oral hypoglycemic agents (P < .001) compared to noninsulin secretagogues. CGMS analysis resulted in treatment modifications in 64% of the patients. T2DM patients on insulin exhibited higher glycemic variability (GV) scores (2.3 ± 0.6) as compared to those on oral medications (1.8 ± 0.7, P = .017). CGMS can provide rich data that show glucose excursions in diabetes patients throughout the day. Consequently, unwarranted onset of hypo- and hyperglycemic events can be detected, intervened, and prevented by using CGMS. Hypoglycemia was frequently unrecognized by the patients in this study (75%), which increases their potential risk of significant adverse events. Incorporation of CGMS into the routine management of T2DM would increase the detection and self-awareness of hypoglycemia resulting in safer and potentially better overall control. © 2015 Diabetes Technology Society.

  15. Vascular Glucose Sensor Symposium: Continuous Glucose Monitoring Systems (CGMS) for Hospitalized and Ambulatory Patients at Risk for Hyperglycemia, Hypoglycemia, and Glycemic Variability.

    PubMed

    Joseph, Jeffrey I; Torjman, Marc C; Strasma, Paul J

    2015-07-01

    Hyperglycemia, hypoglycemia, and glycemic variability have been associated with increased morbidity, mortality, length of stay, and cost in a variety of critical care and non-critical care patient populations in the hospital. The results from prospective randomized clinical trials designed to determine the risks and benefits of intensive insulin therapy and tight glycemic control have been confusing; and at times conflicting. The limitations of point-of-care blood glucose (BG) monitoring in the hospital highlight the great clinical need for an automated real-time continuous glucose monitoring system (CGMS) that can accurately measure the concentration of glucose every few minutes. Automation and standardization of the glucose measurement process have the potential to significantly improve BG control, clinical outcome, safety and cost. © 2015 Diabetes Technology Society.

  16. [Clinical use of continuous glucose monitoring system in gestational diabetes mellitus and type 2 diabetes complicated with pregnancy].

    PubMed

    Song, Yilin; Yang, Huixia

    2014-08-01

    To compare the clinical use of continuous glucose monitoring system (CGMS) and self-monitoring blood glucose (SMBG) when monitoring blood glucose level of patients with gestational diabetes mellitus (GDM) or type 2 diabetes mellitus (DM) complicated with pregnancy. A total of 99 patients with GDM (n = 70) and type 2 DM complicated with pregnancy (n = 29) that whether hospitalized or in clinical of Peking University First Hospital were recruited from Aug 2012 to Apr 2013. The CGMS was used to monitor their blood glucose level during the 72-hour time period, while the SMBG was also taken seven times daily. The correlation between these blood glucose levels and their glycosylated hemoglobin (HbA1c) levels were analyzed by comparing the average value, the maximum and the minimum value of blood glucose, and the appeared time of these extremum values in these two monitoring methods, and the amount of insulin usage was recorded as well. (1) The maximum, minimum and the average blood glucose value in the GDM group were (8.7 ± 1.2), (4.5 ± 0.6)and (6.3 ± 0.6)mmol/L of SMBG vs. (10.1 ± 1.7), (3.1 ± 0.7), (6.0 ± 0.6) mmol/L of CGMS. These values in DM group were(10.1 ± 2.2), (4.5 ± 1.0), (6.9 ± 1.1)mmol/L of SMBG vs.(12.2 ± 2.6), (2.8 ± 0.8), (6.6 ± 1.1) mmol/L of CGMS. By using the two methods, the maximum and the average value of the two groups showed significant differences (P < 0.01) while the minimum value showed no significant differences (P > 0.05). (2) In the GDM group, the average blood glucose values of CGMS and SMBG were significantly correlated (r = 0.864, P < 0.01). The maximum values presented the same result (r = 0.734, P < 0.01). Correlation was not found in the minimum values of CGMS and SMBG (r = 0.138, P > 0.05). In the DM group, the average valves of two methods were significantly correlated (r = 0.962, P < 0.01), the maximum values showed the same result (r = 0.831, P < 0.01).It can also be observed in the minimum values (r = 0.460, P < 0.05). (3) There was significant correlation between the average value of CGMS and HbA1c level (r = 0.400, P < 0.01), and the average value of SMBG and HbA1c level were correlated (r = 0.031, P < 0.05) in the GDM group; the average values of CGMS (r = 0.695, P < 0.01) and SMBG (r = 0.673, P < 0.01) were both significantly correlated with the HbA1c level in the DM group. (4) In the GDM group, 37% (26/70) of the minimum values of SMBG appeared 30 minutes before breakfast, while 34% (24/70) of them appeared 30 minutes before lunch; 86% (60/70) of the maximum values of SMBG were evenly distributed 2 hours after each of the three meals. In the DM group, 41% (12/29) of the minimum values of SMBG presented 30 minutes before lunch, while 21% (6/29) and 14% (4/29) of them were showed 30 minutes before breakfast and dinner respectively; about 30% of the maximum values of SMBG appeared 2 hours after each of the three meals. (5) In the GDM group, 23% (16/70) of the minimum values of CGMS occurred between 0:00-2:59 am., and most of the other minimum values of CGMS were evenly distributed in the rest of the day, except for 3% (2/70) of them were found during 18:00- 20:59 pm. 43% (30/70) of the maximum values of CGMS appeared during 6:00-8:59 am., only 1% (1/70) and 3% (2/70) of them presented during 0:00-2:59 am. and 21:00-23:59 pm., and the rest were evenly distributed for the other times of the day. In the DM group, 34% (10/29) of the minimum values of CGMS were found during 0:00-2:59 am., 14% (4/29) of them appeared during 9:00-11:59 am. and 15:00-17:59 pm., 45% (13/29) of the maximum values of the CGMS presented during 6:00-8:59 am., none was found during 21:00-23:59 pm.,0:00-2:59 am. and 3:00-5:59 am., and the rest were evenly distributed for the other times of the day. (6) 64% (45/70) of the patients in the GDM group did not require for insulin treatment, while 36% (25/70) of them did. For those patients who received insulin treatment, after CGMS, 64% (16/25) of them adjusted the insulin dosage according to their blood glucose levels. In the DM group, 14% (4/29) of them did not receive insulin treatment, while for the others who did (86%, 25/29); 60% (15/25) of them adjusted the insulin dosage according to their blood glucose levels after CGMS. Both CGMS and SMBG could correctly reflect patients' blood glucose levels. It was more difficult to control the blood glucose levels in patients with type 2 DM complicated with pregnancy than the GDM patients. Compared with SMBG, CGMS could detect postprandial hyperglycemia and nocturnal hypoglycemia more effectively.

  17. Assessment of hypoglycaemia awareness using continuous glucose monitoring.

    PubMed

    Kubiak, T; Hermanns, N; Schreckling, H J; Kulzer, B; Haak, T

    2004-05-01

    To investigate the possibility of assessing hypoglycaemia awareness in patients with Type 1 diabetes using continuous glucose monitoring. Twenty patients with Type 1 diabetes were investigated. Ten patients with Type 1 diabetes and strongly impaired hypoglycaemia awareness were compared with 10 patients with intact hypoglycaemia awareness regarding quality of hypoglycaemia perception (number of undetected hypoglycaemic episodes per 24 h, glucose level < 3.3 mmol/l). Hypoglycaemia detection was assessed using the event function of the Continuous Glucose Monitoring System (CGMS; Medtronic MiniMed, Northridge, CA, USA). Patients were instructed to enter an event upon suspecting being hypoglycaemic. Satisfactory CGMS performance could be achieved [mean r = 0.893 between calibration measurements and CGMS data, mean absolute difference (MAD) = 20.6%], although artefacts were observable and had to be controlled. Hypoglycaemia unaware patients showed a significantly higher total number of hypoglycaemic episodes (P < 0.05), number of undetected hypoglycaemic episodes (P < 0.01), and mean glucose levels (P < 0.05). Even in aware patients, undetected hypoglycaemia was observable. No significant differences regarding occurrence of nocturnal hypoglycaemia were observable. The possibility of direct assessment of hypoglycaemia awareness using continuous glucose monitoring was demonstrated. Its application in clinical practice could be of use for assessing hypoglycaemia perception and evaluating the impact of treatment changes on hypoglycaemia awareness.

  18. Current concepts in blood glucose monitoring

    PubMed Central

    Khadilkar, Kranti Shreesh; Bandgar, Tushar; Shivane, Vyankatesh; Lila, Anurag; Shah, Nalini

    2013-01-01

    Blood glucose monitoring has evolved over the last century. The concept of adequate glycemic control and minimum glycemic variability requires an ideal, accurate and reliable glucose monitoring system. The search for an ideal blood glucose monitoring system still continues. This review explains the various blood glucose monitoring systems with special focus on the monitoring systems like self- monitored blood glucose (SMBG) and continuous glucose monitoring system (CGMS). It also focuses on the newer concepts of blood glucose monitoring and their incorporation in routine clinical management of diabetes mellitus. PMID:24910827

  19. A history of continuous glucose monitors (CGMs) in self-monitoring of diabetes mellitus.

    PubMed

    Olczuk, David; Priefer, Ronny

    Self-monitoring of glucose for individuals afflicted with diabetes mellitus has allowed patients to take control of their disease and thus directly affect the outcomes related to it. It has been almost a century since the first test to monitor one's sugar was developed; that being a urine test. The most well-known and prominent medical device for monitor blood glucose for individuals with diabetes are the finger-prick devices. This itself is an approximately 50year old technology. More recently has been the introduction of continuous glucose monitors (CGMs) which entered the market place in the last year of the 20th century. As this technology has been further refined and improved, limitations associated with it have decreased. The scope of this review is to present a brief history of CGMs, both with the development of these medical devices and the challenges/limitations that they have shown. Copyright © 2017 Diabetes India. Published by Elsevier Ltd. All rights reserved.

  20. [From insulin pump and continuous glucose monitoring to the artificial pancreas].

    PubMed

    Apablaza, Pamela; Soto, Néstor; Codner, Ethel

    2017-05-01

    Technology for diabetes care has undergone major development during recent decades. These technological advances include continuous subcutaneous insulin infusion (CSII), also known as insulin pumps, and real-time continuous glucose monitoring system (RT-CGMS). The integration of CSII and RT-CGMS into a single device has led to sensor-augmented pump therapy and more recently, a technology that has automated delivery of basal insulin therapy, known as hybrid system. These new technologies have led to benefits in attaining better metabolic control and decreasing the incidence of severe hypoglycemia, especially in patients with type 1 diabetes. This review describes the types of technologies currently available or under investigation for these purposes, their benefits and disadvantages, recommendations and the appropriate patient selection for their use. The clinical use of the hybrid system and artificial pancreas seem to be possible in the near future.

  1. [Current status and recommendations on the use of continuous blood glucose monitoring systems in children and adolescents with type 1 diabetes mellitus].

    PubMed

    Torres Lacruz, M; Barrio Castellanos, R; García Cuartero, B; Gómez Gila, A; González Casado, I; Hermoso López, F; Luzuriaga Tomás, C; Oyarzabal Irigoyen, M; Rica Etxebarria, I; Rodríguez Rigual, M

    2011-08-01

    Glucose monitoring methods have made great advances in the last decade with the appearance of the continuous glucose monitoring systems (CGMS) that measure the glucose levels in the interstitial liquid, providing information about glucose patterns and trends, but do not replace the self-monitoring of capillary glucose. Improvement in diabetes control using the CGMS depends on the motivation and training received by the patient and family and on the continuity in its use. Due to the development and widespread use of these systems in clinical practice, the diabetes group of the Sociedad Española de Endocrinología Pediátrica has drafted a document of consensus for their indication and use in children and adolescents. Only a limited number of trials have been performed in children and adolescent populations. More data are needed on the use of this technology in order to define the impact on metabolic control. Copyright © 2010 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  2. Sensitivity and specificity of different methods for cystic fibrosis-related diabetes screening: is the oral glucose tolerance test still the standard?

    PubMed

    Mainguy, Catherine; Bellon, Gabriel; Delaup, Véronique; Ginoux, Tiphanie; Kassai-Koupai, Behrouz; Mazur, Stéphane; Rabilloud, Muriel; Remontet, Laurent; Reix, Philippe

    2017-01-01

    Cystic fibrosis-related diabetes (CFRD) is a late cystic fibrosis (CF)-associated comorbidity whose prevalence is increasing sharply lifelong. Guidelines for glucose metabolism (GM) monitoring rely on the oral glucose tolerance test (OGTT). However, this test is neither sensitive nor specific. The aim of this study was to compare sensitivity and specificity of different methods for GM monitoring in children and adolescents with CF. Continuous glucose monitoring system (CGMS), used as the reference method, was compared with the OGTT, intravenous glucose tolerance test (IGTT), homeostasis model assessment index of insulin resistance (HOMA-IR), homeostasis model assessment index of β-cell function (HOMA-%B) and glycated haemoglobin A1C. Patients were classified into three groups according to CGMS: normal glucose tolerance (NGT), impaired glucose tolerance (IGT) and diabetes mellitus (DM). Twenty-nine patients (median age: 13.1 years) were recruited. According to CGMS, 11 had DM, 12 IGT and six NGT, whereas OGTT identified three patients with DM and five with IGT. While 13 of 27 had insulin deficiency according to IGTT, there was 19 of 28 according to HOMA-%B. According to HOMA-IR, 12 of 28 had insulin resistance. HOMA-%B was the most sensitive method for CFRD screening [sensitivity 91% (95% CI), specificity 47% (95% CI) and negative predictive value 89% (95% CI)]. OGTT showed the weak capacity to diagnose DM in CF and should no longer be considered as the reference method for CFRD screening in patients with CF. In our study, HOMA-%B showed promising metrics for CFRD screening. Finally, CGMS revealed that pathological glucose excursions were frequent even early in life.

  3. Hypoglycemia in Type 2 Diabetes - More Common Than You Think

    PubMed Central

    Gehlaut, Richa Redhu; Dogbey, Godwin Y.; Schwartz, Frank L.; Marling, Cynthia R.; Shubrook, Jay H.

    2015-01-01

    Background: Hypoglycemia is often the limiting factor for intensive glucose control in diabetes management, however its actual prevalence in type 2 diabetes (T2DM) is not well documented. Methodology: A total of 108 patients with T2DM wore a continuous glucose monitoring system (CGMS) for 5 days. Rates and patterns of hypoglycemia and glycemic variability (GV) were calculated. Patient and medication factors were correlated with rates, timing, and severity of hypoglycemia. Results: Of the patients, 49.1% had at least 1 hypoglycemic episode (mean 1.74 episodes/patient/ 5 days of CGMS) and 75% of those patients experienced at least 1 asymptomatic hypoglycemic episode. There was no significant difference in the frequency of daytime versus nocturnal hypoglycemia. Hypoglycemia was more frequent in individuals on insulin (alone or in combination) (P = .02) and those on oral hypoglycemic agents (P < .001) compared to noninsulin secretagogues. CGMS analysis resulted in treatment modifications in 64% of the patients. T2DM patients on insulin exhibited higher glycemic variability (GV) scores (2.3 ± 0.6) as compared to those on oral medications (1.8 ± 0.7, P = .017). Conclusions: CGMS can provide rich data that show glucose excursions in diabetes patients throughout the day. Consequently, unwarranted onset of hypo- and hyperglycemic events can be detected, intervened, and prevented by using CGMS. Hypoglycemia was frequently unrecognized by the patients in this study (75%), which increases their potential risk of significant adverse events. Incorporation of CGMS into the routine management of T2DM would increase the detection and self-awareness of hypoglycemia resulting in safer and potentially better overall control. PMID:25917335

  4. Evaluation of factors affecting CGMS calibration.

    PubMed

    Buckingham, Bruce A; Kollman, Craig; Beck, Roy; Kalajian, Andrea; Fiallo-Scharer, Rosanna; Tansey, Michael J; Fox, Larry A; Wilson, Darrell M; Weinzimer, Stuart A; Ruedy, Katrina J; Tamborlane, William V

    2006-06-01

    The optimal number/timing of calibrations entered into the CGMS (Medtronic MiniMed, Northridge, CA) continuous glucose monitoring system have not been previously described. Fifty subjects with Type 1 diabetes mellitus (10-18 years old) were hospitalized in a clinical research center for approximately 24 h on two separate days. CGMS and OneTouch Ultra meter (LifeScan, Milpitas, CA) data were obtained. The CGMS was retrospectively recalibrated using the Ultra data varying the number and timing of calibrations. Resulting CGMS values were compared against laboratory reference values. There was a modest improvement in accuracy with increasing number of calibrations. The median relative absolute deviation (RAD) was 14%, 15%, 13%, and 13% when using three, four, five, and seven calibration values, respectively (P < 0.001). Corresponding percentages of CGMS-reference pairs meeting the International Organisation for Standardisation criteria were 66%, 67%, 71%, and 72% (P < 0.001). Nighttime accuracy improved when daytime calibrations (pre-lunch and pre-dinner) were removed leaving only two calibrations at 9 p.m. and 6 a.m. (median difference, -2 vs. -9 mg/dL, P < 0.001; median RAD, 12% vs. 15%, P = 0.001). Accuracy was better on visits where the average absolute rate of glucose change at the times of calibration was lower. On visits with average absolute rates <0.5, 0.5 to <1.0, 1.0 to <1.5, and >or=1.5 mg/dL/min, median RAD values were 13% versus 14% versus 17% versus 19%, respectively (P = 0.05). Although accuracy is slightly improved with more calibrations, the timing of the calibrations appears more important. Modifying the algorithm to put less weight on daytime calibrations for nighttime values and calibrating during times of relative glucose stability may have greater impact on accuracy.

  5. Continuous glucose monitoring: a valuable monitoring tool for management of hypoglycemia during chemotherapy for acute lymphoblastic leukemia.

    PubMed

    Visavachaipan, Nipapat; Aledo, Alexander; Franklin, Bonita H; Brar, Preneet C

    2013-01-01

    Acute lymphoblastic leukemia (ALL) maintenance therapy (MT) has been occasionally associated with symptomatic hypoglycemia (SH), attributed to purine analog (mercaptopurine [6-MP]). This hypoglycemia has been hypothesized to affect substrate utilization of gluconeogenic precursor alanine in the liver. An overweight 5-year-old boy with ALL was evaluated for SH (lethargy and vomiting) that occurred 8-10 h after fasting while receiving daily 6-MP. Hypoglycemic episodes (>20 episodes per month) occurred predominantly around midmorning but not during the 5-day dexamethasone pulse. The adrenocorticotropic hormone test yielded a normal cortisol response, which ruled out pituitary adrenal suppression. A 12-h overnight fasting glucose was 49 mg/dL, with suppressed insulin response <2 IU/mL, low C-peptide of 0.5 ng/mL, high insulin-like growth factor-binding protein >160 ng/mL, high free fatty acid of 2.64 mmol/L, and negative glucagon stimulation test (change in blood glucose [BG] <5 mg/dL). These results ruled out hyperinsulinism. The patient was placed on cornstarch therapy 5 h prior to dosing with 6-MP. This treatment reduced the SH events to fewer than two episodes per month. To study the efficacy of cornstarch, the patient was fitted with the iPro™ professional continuous glucose monitoring system (CGMS) (Medtronic MiniMed, Northridge, CA) with a preset low alarm at 70 mg/dL, which was worn for a period of 5 days while the patient was on cornstarch. With 1,000 sensor reading the BG range was 65-158 mg/dL, and the percentage mean absolute difference between sensor and finger-stick BG readings (the parent monitored his BG four times a day) was 9.4%. There were no hypoglycemic episodes detected by the CGMS while the patient was on cornstarch. After the cessation of chemotherapy, a 15-h fasting study was performed, and the CGMS was placed. Results showed resolution of hypoglycemia. The CGMS helped us devise an effective management plan for our patient. CGMS proved useful as an adjunct to characterize the pattern of hypoglycemia and to validate the benefit of cornstarch in hypoglycemia associated with 6-MP treatment of ALL.

  6. Comparison of Glycemic Excursion in Patients with New Onset Type 2 Diabetes Mellitus before and after Treatment with Repaglinide.

    PubMed

    Hezarkhani, Sharabeh; Bonakdaran, Shokufeh; Rajabian, Reza; Shahini, Najmeh; Marjani, Abdoljalal

    2013-01-01

    Due to industrialization and sedentary life, incidence of type 2 diabetes (DM2) is increasing seriously. Repaglinide is a glucose reducing agent that predominantly reduces post-prandial glucose. Continuous glucose monitoring system (CGMS) monitors blood glucose excursions over a 3-day period. CGMS can be used as a therapeutic and diagnostic instrument in diabetics. There are not enough studies about using CGMS in DM2. The aim of this study was to determine the blood glucose excursions in patients with new onset of DM2. 10 patients with new onset of DM2 were entered to this study. As the first therapeutic management, patients received diabetic diet and moderate exercise for 3-weeks, if they did not achieve blood glucose goal (Fasting blood glucoser (FBG) <120mg/dl, 2-hour postprandial blood glucose (2hpp) <180mg/dl), were considered to undergo 3-days CGMS at baseline and after 4-weeks on Repaglinide (0.5mg three times before meals). Mean excursions of blood glucose were not different at the onset and at the end of treatment (6±4.05 VS 7.6±5.2 episodes, P=0.49). There were also no significant differences between mean duration of hypoglycemic episodes (zero VS 5.1±14.1 hours, P =0.28) and hyperglycemic episodes before and after therapy (7.6±5.2 VS 5.7±4.1, P=0.42), but mean hyperglycemia duration was significantly reduced at the end of therapy (21±26.17 VS 57.7±35.3, P=0.001). Patients experienced a mean of 0.3±0.67 episodes of hypoglycemia after therapy showed no significant difference before it (P =0.19). Mean FBG (with CGMS) was significantly lower after therapy than before it (142.9±54.31 VS 222.9±82.6, P <0.001). This study showed the usefulness of CGMS not only as a diagnostic but also as an educational and therapeutic tool that in combination with Repaglinide (with the lowest effective dose and duration) can significantly reduce FBG and glycemic excursions in DM2 patients and hypoglycemic events are low.

  7. Monthly use of a real-time continuous glucose monitoring system as an educational and motivational tool for poorly controlled type 1 diabetes adolescents.

    PubMed

    Głowińska-Olszewska, B; Tobiaszewska, M; Łuczyński, W; Bossowski, A

    2013-01-01

    Experience with the use of real-time continuous glucose monitoring systems (RT-CGMS) in teenagers with type 1 diabetes mellitus (T1DM) is limited. We aimed to assess the possibility of glycaemic control improvement and to characterize the group of adolescents, who may gain long-term benefits from the use of the RT-CGMS. Forty T1DM patients, aged 14.6 ± 2.1 years, with diabetes duration 7.4 ± 3.6 years and initial HbA₁c 9.3 ± 1.5% were recruited. The analysis was based on one-month glucose sensors use, combined with the thorough family support. Patients were analysed in groups according to baseline HbA₁c: below and above 7.5%, and 10.0%. Comparison between patients with or without improvement in HbA₁c after 3-month follow-up was also performed. Patients' satisfaction based on the questionnaire was assessed. HbA₁c level in entire study group decreased after three months, from 9.3 ± 1.0% to 8.8 ± 1.6% (P<0.001). In the group with HbA1c improvement, reduction was the highest: 9.0 ± 1.3% vs. 8.0 ± 1.2% (P<0.001). Only the group with initial HbA₁c>10% did not achieve significant improvement: 11.2 ± 0.5% vs. 10.9 ± 1.1 (P=0.06). In satisfaction questionnaire the lowest scores (negative opinion) were reported by group of patients with initial HbA₁c above 10%, while the highest scores (positive opinion) were found in the group with improvement of HbA₁c after 3 month follow-up. Short-term use of CGMS RT, united with satisfaction questionnaire, performed in poorly controlled teenagers with T1DM, can be useful in defining the group of young patients, who can benefit from long-term CGMS RT use in metabolic control improvement.

  8. Test-retest reliability of a continuous glucose monitoring system in individuals with type 2 diabetes.

    PubMed

    Terada, Tasuku; Loehr, Sarah; Guigard, Emmanuel; McCargar, Linda J; Bell, Gordon J; Senior, Peter; Boulé, Normand G

    2014-08-01

    This study determined the test-retest reliability of a continuous glucose monitoring system (CGMS) (iPro™2; Medtronic, Northridge, CA) under standardized conditions in individuals with type 2 diabetes (T2D). Fourteen individuals with T2D spent two nonconsecutive days in a calorimetry unit. On both days, meals, medication, and exercise were standardized. Glucose concentrations were measured continuously by CGMS, from which daily mean glucose concentration (GLU(mean)), time spent in hyperglycemia (t(>10.0 mmol/L)), and meal, exercise, and nocturnal mean glucose concentrations, as well as glycemic variability (SD(w), percentage coefficient of variation [%cv(w)], mean amplitude of glycemic excursions [MAGEc, MAGE(ave), and MAGE(abs.gos)], and continuous overlapping net glycemic action [CONGA(n)]) were estimated. Absolute and relative reliabilities were investigated using coefficient of variation (CV) and intraclass correlation, respectively. Relative reliability ranged from 0.77 to 0.95 (P<0.05) for GLU(mean) and meal, exercise, and nocturnal glycemia with CV ranging from 3.9% to 11.7%. Despite significant relative reliability (R=0.93; P<0.01), t(>10.0 mmol/L) showed larger CV (54.7%). Among the different glycemic variability measures, a significant between-day difference was observed in MAGEc, MAGE(ave), CONGA6, and CONGA12. The remaining measures (i.e., SD(w), %cv(w), MAGE(abs.gos), and CONGA1-4) indicated no between-day differences and significant relative reliability. In individuals with T2D, CGMS-estimated glycemic profiles were characterized by high relative and absolute reliability for both daily and shorter-term measurements as represented by GLUmean and meal, exercise, and nocturnal glycemia. Among the different methods to calculate glycemic variability, our results showed SD(w), %cv(w), MAGE(abs.gos), and CONGAn with n ≤ 4 were reliable measures. These results suggest the usefulness of CGMS in clinical trials utilizing repeated measured.

  9. Electromagnetic interference from electronic devices used in the management of type 1 diabetes can impair the performance of an avalanche transceiver in search mode.

    PubMed

    Miller, Steven C M

    2015-06-01

    Portable electronic devices play an important role in the management of type 1 diabetes mellitus. Electromagnetic interference from electronic devices has been shown to impair the function of an avalanche transceiver in search mode (but not in transmitting mode). This study investigates the influence of electromagnetic interference from diabetes devices on a searching avalanche beacon. The greatest distance at which an avalanche transceiver (in search mode) could accurately indicate the location of a transmitting transceiver was assessed when portable electronic devices (including an insulin pump and commonly used real-time continuous subcutaneous glucose monitoring system [rtCGMS]) were held in close proximity to each transceiver. The searching transceiver could accurately locate a transmitted signal at a distance of 30 m when used alone. This distance was unchanged by the Dexcom G4 rtCGMS, but was reduced to 10 m when the Medtronic Guardian rtCGMS was held close (within 30 cm) to the receiving beacon. Interference from the Animas Vibe insulin pump reduced this distance to 5 m, impairing the searching transceiver in a manner identical to the effect of a cell phone. Electromagnetic interference produced by some diabetes devices when held within 30 cm of a searching avalanche transceiver can impair the ability to locate a signal. Such interference could significantly compromise the outcome of a companion rescue scenario. Further investigation using other pumps and rtCGMS devices is required to evaluate all available diabetes electronics. Meantime, all electronic diabetes devices including rtCGMS and insulin pumps should not be used within 30 cm of an avalanche transceiver. Copyright © 2015 Wilderness Medical Society. Published by Elsevier Inc. All rights reserved.

  10. Evaluation of Factors Affecting CGMS Calibration

    PubMed Central

    2006-01-01

    Background The optimal number/timing of calibrations entered into the Continuous Glucose Monitoring System (“CGMS”; Medtronic MiniMed, Northridge, CA) have not been previously described. Methods Fifty subjects with T1DM (10–18y) were hospitalized in a clinical research center for ~24h on two separate days. CGMS and OneTouch® Ultra® Meter (“Ultra”; LifeScan, Milpitas, CA) data were obtained. The CGMS was retrospectively recalibrated using the Ultra data varying the number and timing of calibrations. Resulting CGMS values were compared against laboratory reference values. Results There was a modest improvement in accuracy with increasing number of calibrations. The median relative absolute deviation (RAD) was 14%, 15%, 13% and 13% when using 3, 4, 5 and 7 calibration values, respectively (p<0.001). Corresponding percentages of CGMS-reference pairs meeting the ISO criteria were 66%, 67%, 71% and 72% (p<0.001). Nighttime accuracy improved when daytime calibrations (pre-lunch and pre-dinner) were removed leaving only two calibrations at 9p.m. and 6a.m. (median difference: −2 vs. −9mg/dL, p<0.001; median RAD: 12% vs. 15%, p=0.001). Accuracy was better on visits where the average absolute rate of glucose change at the times of calibration was lower. On visits with average absolute rates <0.5, 0.5-<1.0, 1.0-<1.5 and ≥1.5mg/dL/min, median RAD values were 13% vs. 14% vs. 17% vs. 19%, respectively (p=0.05). Conclusions Although accuracy is slightly improved with more calibrations, the timing of the calibrations appears more important. Modifying the algorithm to put less weight on daytime calibrations for nighttime values and calibrating during times of relative glucose stability may have greater impact on accuracy. PMID:16800753

  11. Nocturnal hypoglycemia identified by a continuous glucose monitoring system in patients with primary adrenal insufficiency (Addison's Disease).

    PubMed

    Meyer, Gesine; Hackemann, Annika; Reusch, Juergen; Badenhoop, Klaus

    2012-05-01

    Hypoglycemia can be a symptom in patients with Addison's disease. The common regimen of replacement therapy with oral glucocorticoids results in unphysiological low cortisol levels in the early morning, the time of highest insulin sensitivity. Therefore patients with Addison's disease are at risk for unrecognized and potentially severe nocturnal hypoglycemia also because of a disturbed counterregulatory function. Use of a continuous glucose monitoring system (CGMS) could help to adjust hydrocortisone treatment and to avoid nocturnal hypoglycemia in these patients. Thirteen patients with Addison's disease were screened for hypoglycemia wearing a CGMS for 3-5 days. In one patient we identified a hypoglycemic episode at 3:45 a.m. with a blood glucose level of 46 mg/dL, clearly beneath the 95% tolerance interval of minimal glucose levels between 2 and 4 a.m. (53.84 mg/dL). After the hydrocortisone replacement scheme was changed, the minimum blood glucose level between 2 and 4 a.m. normalized to 87 mg/dL. Continuous glucose monitoring can detect nocturnal hypoglycemia in patients with primary adrenal insufficiency and hence prevent in these patients an impaired quality of life and even serious adverse effects.

  12. Nocturnal Hypoglycemia Identified by a Continuous Glucose Monitoring System in Patients with Primary Adrenal Insufficiency (Addison's Disease)

    PubMed Central

    Hackemann, Annika; Reusch, Juergen; Badenhoop, Klaus

    2012-01-01

    Abstract Background Hypoglycemia can be a symptom in patients with Addison's disease. The common regimen of replacement therapy with oral glucocorticoids results in unphysiological low cortisol levels in the early morning, the time of highest insulin sensitivity. Therefore patients with Addison's disease are at risk for unrecognized and potentially severe nocturnal hypoglycemia also because of a disturbed counterregulatory function. Use of a continuous glucose monitoring system (CGMS) could help to adjust hydrocortisone treatment and to avoid nocturnal hypoglycemia in these patients. Methods Thirteen patients with Addison's disease were screened for hypoglycemia wearing a CGMS for 3–5 days. Results In one patient we identified a hypoglycemic episode at 3:45 a.m. with a blood glucose level of 46 mg/dL, clearly beneath the 95% tolerance interval of minimal glucose levels between 2 and 4 a.m. (53.84 mg/dL). After the hydrocortisone replacement scheme was changed, the minimum blood glucose level between 2 and 4 a.m. normalized to 87 mg/dL. Conclusions Continuous glucose monitoring can detect nocturnal hypoglycemia in patients with primary adrenal insufficiency and hence prevent in these patients an impaired quality of life and even serious adverse effects. PMID:22242902

  13. Privacy and Security Issues Surrounding the Protection of Data Generated by Continuous Glucose Monitors.

    PubMed

    Britton, Katherine E; Britton-Colonnese, Jennifer D

    2017-03-01

    Being able to track, analyze, and use data from continuous glucose monitors (CGMs) and through platforms and apps that communicate with CGMs helps achieve better outcomes and can advance the understanding of diabetes. The risks to patients' expectation of privacy are great, and their ability to control how their information is collected, stored, and used is virtually nonexistent. Patients' physical security is also at risk if adequate cybersecurity measures are not taken. Currently, data privacy and security protections are not robust enough to address the privacy and security risks and stymies the current and future benefits of CGM and the platforms and apps that communicate with them.

  14. Privacy and Security Issues Surrounding the Protection of Data Generated by Continuous Glucose Monitors

    PubMed Central

    Britton, Katherine E.; Britton-Colonnese, Jennifer D.

    2017-01-01

    Being able to track, analyze, and use data from continuous glucose monitors (CGMs) and through platforms and apps that communicate with CGMs helps achieve better outcomes and can advance the understanding of diabetes. The risks to patients’ expectation of privacy are great, and their ability to control how their information is collected, stored, and used is virtually nonexistent. Patients’ physical security is also at risk if adequate cybersecurity measures are not taken. Currently, data privacy and security protections are not robust enough to address the privacy and security risks and stymies the current and future benefits of CGM and the platforms and apps that communicate with them. PMID:28264188

  15. Treatment with continuous positive airway pressure may affect blood glucose levels in nondiabetic patients with obstructive sleep apnea syndrome.

    PubMed

    Czupryniak, Leszek; Loba, Jerzy; Pawlowski, Maciej; Nowak, Dariusz; Bialasiewicz, Piotr

    2005-05-01

    Obstructive sleep apnea syndrome (OSAS) is often associated with impaired glucose metabolism. Data on the effects of OSAS treatment with continuous positive airway pressure (CPAP) on blood glucose and insulin resistance are conflicting. The study aimed at assessing the immediate effect of CPAP on glucose control measured with a continuous glucose monitoring system (CGMS). Nine non-diabetes subjects with OSAS (mean age 53.0 +/- 8.0 years; body mass index 34.8 +/- 5.3 kg/m2) underwent 2 overnight polysomnographic examinations: a diagnostic study and one with CPAP treatment. Continuous glucose monitoring system (CGMS) was applied overnight on both occasions. Glucose metabolism was assessed with a 75-g oral glucose tolerance test, plasma insulin and homeostatic model assessment of insulin resistance (HOMA-IR) index. The mean (+/- SD) apnoea-hypopnea index (AHI) at diagnostic polysomnography was 54.3 +/- 29.3 (range 16-81). Fasting plasma insulin levels in patients with OSAS was 84.3 +/- 43.4 pM at baseline, and the HOMA-IR was 3.6 +/- 2.2. CPAP treatment in the subjects with OSAS resulted in a significant reduction in the AHI to 4.5 +/- 7.1. All of the major saturation parameters improved significantly on CPAP. CGMS showed mean glucose values significantly higher during the CPAP night than during the diagnostic night: 80 +/- 11 mg/dL versus 63 +/- 7 mg/dL (P < .01). Fasting insulin and HOMA-IR measured after the CPAP night tended to be higher than at baseline (98.4 +/- 51.0 pmol vs 84.3 +/- 43.4 pmol and 3.9 pmol +/- 2.6 vs 3.6 +/- 2.2 pmol, respectively, P > .05). CPAP treatment in nondiabetic obese patients with OSAS may have an immediate elevating effect on blood glucose.

  16. Description and Preliminary Evaluation of a Diabetes Technology Simulation Course

    PubMed Central

    Wilson, Rebecca D.; Bailey, Marilyn; Boyle, Mary E.; Seifert, Karen M.; Cortez, Karla Y.; Baker, Leslie J.; Hovan, Michael J.; Stepanek, Jan; Cook, Curtiss B.

    2013-01-01

    Background We aim to provide data on a diabetes technology simulation course (DTSC) that instructs internal medicine residents in the use of continuous subcutaneous insulin infusion (CSII) and continuous glucose monitoring system (CGMS) devices. Methods The DTSC was implemented during calendar year 2012 and conducted in the institution’s simulation center. It consisted of a set of prerequisites, a practicum, and completion of a web-based inpatient CSII-ordering simulation. DTSC participants included only those residents in the outpatient endocrinology rotation. Questionnaires were used to determine whether course objectives were met and to assess the satisfaction of residents with the course. Questionnaires were also administered before and after the endocrine rotation to gauge improvement in familiarity with CSII and CGMS technologies. Results During the first year, 12 of 12 residents in the outpatient endocrinology rotation completed the DTSC. Residents reported that the course objectives were fully met. The mean satisfaction score with the course ranged from 4.0 to 4.9 (maximum, 5), with most variables rated above 4.5. Self-reported familiarity with the operation of CSII and CGMS devices increased significantly in the postrotation survey compared with that on the prerotation survey (both p < .01). Conclusions In this pilot program, simulation-based education increased the perceived familiarity of residents with CSII and CGMS technologies. In light of these preliminary findings, the course will continue to be offered, with further data accrual. Future work will involve piloting the DTSC approach among other types of providers, such as residents in other specialties or inpatient nursing staff. PMID:24351182

  17. A comparative effectiveness analysis of three continuous glucose monitors: the Navigator, G4 Platinum, and Enlite.

    PubMed

    Damiano, Edward R; McKeon, Katherine; El-Khatib, Firas H; Zheng, Hui; Nathan, David M; Russell, Steven J

    2014-07-01

    The effectiveness and safety of continuous glucose monitors (CGMs) is dependent on their accuracy and reliability. The objective of this study was to compare 3 CGMs in adult and pediatric subjects with type 1 diabetes under closed-loop blood-glucose (BG) control. Twenty-four subjects (12 adults) with type 1 diabetes each participated in one 48-hour closed-loop BG control experiment. Venous plasma glucose (PG) measurements obtained every 15 minutes (4657 values) were paired in time with corresponding CGM glucose (CGMG) measurements obtained from 3 CGMs (FreeStyle Navigator, Abbott Diabetes Care; G4 Platinum, Dexcom; Enlite, Medtronic) worn simultaneously by each subject. The Navigator and G4 Platinum (G4) had the best overall accuracy, with an aggregate mean absolute relative difference (MARD) of all paired points of 12.3 ± 12.1% and 10.8 ± 9.9%, respectively. Both had lower MARDs of all paired points than Enlite (17.9 ± 15.8%, P < .005). Very large errors (MARD > 50%) were less common with the G4 (0.5%) than with the Enlite (4.3%, P = .0001) while the number of very large errors with the Navigator (1.4%) was intermediate between the G4 and Enlite (P = .1 and P = .06, respectively). The average MARD for experiments in adolescent subjects were lower than in adult subjects for the Navigator and G4, while there was no difference for Enlite. All 3 devices had similar reliability. A comprehensive head-to-head-to-head comparison of 3 CGMs revealed marked differences in both accuracy and precision. The Navigator and G4 were found to outperform the Enlite in these areas. © 2014 Diabetes Technology Society.

  18. Daily energy expenditure, cardiorespiratory fitness and glycaemic control in people with type 1 diabetes.

    PubMed

    Valletta, John Joseph; Chipperfield, Andrew J; Clough, Geraldine F; Byrne, Christopher D

    2014-01-01

    Encouraging daily physical activity improves cardiorespiratory fitness and many cardiovascular risk factors. However, increasing physical activity often creates a challenge for people with type 1 diabetes, because of difficulties maintaining euglycemia in the face of altered food intake and adjustments to insulin doses. Our aim was to examine the triangular relationship between glucose control measured by continuous glucose monitoring system (CGMS), objective measures of total daily energy expenditure (TEE) recorded by a multi-sensory monitoring device, and cardiorespiratory fitness (CRF), in free-living subjects with type 1 diabetes. Twenty-three individuals (12 women) with type 1 diabetes who were free from micro- and macrovascular complications were recruited. TEE and glucose control were monitored simultaneously for up to 12 days, using a multi-sensory device and CGMS respectively. CRF was recorded as V02 max from a maximal treadmill test with the Bruce protocol. Subjects (mean±SD) were aged 37±11 years, with BMI = 26.5±5.1 kg.m⁻², HbA1c = 7.7±1.3% (61±14 mmol/mol) and V02 max (ml.min⁻¹.kg⁻¹)  = 39.9±8.4 (range 22.4-58.6). TEE (36.3±5.5 kcal.kg⁻¹.day⁻¹) was strongly associated with CRF(39.9±8.4 ml.min⁻¹.kg⁻¹) independently of sex (r = 0.63, p<0.01). However, neither TEE (r = -0.20, p = 0.36) nor CRF (r = -0.20, p = 0.39; adjusted for sex), were significantly associated with mean glycaemia measured by CGMS. Higher levels of energy expenditure (due to a more active lifestyle) are associated with increased cardiorespiratory fitness, but not necessarily better glycaemic control. Since increased levels of energy expenditure and good glycaemic control are both needed to protect against diabetes-related complications our data suggest they need to be achieved independently.

  19. Evaluating the clinical accuracy of two continuous glucose sensors using continuous glucose-error grid analysis.

    PubMed

    Clarke, William L; Anderson, Stacey; Farhy, Leon; Breton, Marc; Gonder-Frederick, Linda; Cox, Daniel; Kovatchev, Boris

    2005-10-01

    To compare the clinical accuracy of two different continuous glucose sensors (CGS) during euglycemia and hypoglycemia using continuous glucose-error grid analysis (CG-EGA). FreeStyle Navigator (Abbott Laboratories, Alameda, CA) and MiniMed CGMS (Medtronic, Northridge, CA) CGSs were applied to the abdomens of 16 type 1 diabetic subjects (age 42 +/- 3 years) 12 h before the initiation of the study. Each system was calibrated according to the manufacturer's recommendations. Each subject underwent a hyperinsulinemic-euglycemic clamp (blood glucose goal 110 mg/dl) for 70-210 min followed by a 1-mg.dl(-1).min(-1) controlled reduction in blood glucose toward a nadir of 40 mg/dl. Arterialized blood glucose was determined every 5 min using a Beckman Glucose Analyzer (Fullerton, CA). CGS glucose recordings were matched to the reference blood glucose with 30-s precision, and rates of glucose change were calculated for 5-min intervals. CG-EGA was used to quantify the clinical accuracy of both systems by estimating combined point and rate accuracy of each system in the euglycemic (70-180 mg/dl) and hypoglycemic (<70 mg/dl) ranges. A total of 1,104 data pairs were recorded in the euglycemic range and 250 data pairs in the hypoglycemic range. Overall correlation between CGS and reference glucose was similar for both systems (Navigator, r = 0.84; CGMS, r = 0.79, NS). During euglycemia, both CGS systems had similar clinical accuracy (Navigator zones A + B, 88.8%; CGMS zones A + B, 89.3%, NS). However, during hypoglycemia, the Navigator was significantly more clinically accurate than the CGMS (zones A + B = 82.4 vs. 61.6%, Navigator and CGMS, respectively, P < 0.0005). CG-EGA is a helpful tool for evaluating and comparing the clinical accuracy of CGS systems in different blood glucose ranges. CG-EGA provides accuracy details beyond other methods of evaluation, including correlational analysis and the original EGA.

  20. Prolonged episodes of hypoglycaemia in HNF4A-MODY mutation carriers with IGT. Evidence of persistent hyperinsulinism into early adulthood.

    PubMed

    Bacon, S; Kyithar, M P; Condron, E M; Vizzard, N; Burke, M; Byrne, M M

    2016-12-01

    HNF4A is an established cause of maturity onset diabetes of the young (MODY). Congenital hyperinsulinism can also be associated with mutations in the HNF4A gene. A dual phenotype is observed in HNF4A-MODY with hyperinsulinaemic hypoglycaemia in the neonatal period progressing to diabetes in adulthood. The nature and timing of the transition remain poorly defined. We performed an observational study to establish changes in glycaemia and insulin secretion over a 6-year period. We investigated glycaemic variability and hypoglycaemia in HNF4A-MODY using a continuous glucose monitoring system (CGMS). An OGTT with measurement of glucose, insulin and C-peptide was performed in HNF4A participants with diabetes mellitus (DM) (n = 14), HNF4A-IGT (n = 7) and age- and BMI-matched MODY negative family members (n = 10). Serial assessment was performed in the HNF4A-IGT cohort. In a subset of HNF4A-MODY mutation carriers (n = 10), CGMS was applied over a 72-h period. There was no deterioration in glycaemic control in the HNF4A-IGT cohort. The fasting glucose-to-insulin ratio was significantly lower in the HNF4A-IGT cohort when compared to the normal control group (0.13 vs. 0.24, p = 0.03). CGMS profiling demonstrated prolonged periods of hypoglycaemia in the HNF4A-IGT group when compared to the HNF4A-DM group (432 vs. 138 min p = 0.04). In a young adult HNF4A-IGT cohort, we demonstrate preserved glucose, insulin and C-peptide secretory responses to oral glucose. Utilising CGMS, prolonged periods of hypoglycaemia are evident despite a median age of 21 years. We propose a prolonged hyperinsulinaemic phase into adulthood is responsible for the notable hypoglycaemic episodes.

  1. Decreased complexity of glucose dynamics in diabetes: evidence from multiscale entropy analysis of continuous glucose monitoring system data.

    PubMed

    Chen, Jin-Long; Chen, Pin-Fan; Wang, Hung-Ming

    2014-07-15

    Parameters of glucose dynamics recorded by the continuous glucose monitoring system (CGMS) could help in the control of glycemic fluctuations, which is important in diabetes management. Multiscale entropy (MSE) analysis has recently been developed to measure the complexity of physical and physiological time sequences. A reduced MSE complexity index indicates the increased repetition patterns of the time sequence, and, thus, a decreased complexity in this system. No study has investigated the MSE analysis of glucose dynamics in diabetes. This study was designed to compare the complexity of glucose dynamics between the diabetic patients (n = 17) and the control subjects (n = 13), who were matched for sex, age, and body mass index via MSE analysis using the CGMS data. Compared with the control subjects, the diabetic patients revealed a significant increase (P < 0.001) in the mean (diabetic patients 166.0 ± 10.4 vs. control subjects 93.3 ± 1.5 mg/dl), the standard deviation (51.7 ± 4.3 vs. 11.1 ± 0.5 mg/dl), and the mean amplitude of glycemic excursions (127.0 ± 9.2 vs. 27.7 ± 1.3 mg/dl) of the glucose levels; and a significant decrease (P < 0.001) in the MSE complexity index (5.09 ± 0.23 vs. 7.38 ± 0.28). In conclusion, the complexity of glucose dynamics is decreased in diabetes. This finding implies the reactivity of glucoregulation is impaired in the diabetic patients. Such impairment presenting as an increased regularity of glycemic fluctuating pattern could be detected by MSE analysis. Thus, the MSE complexity index could potentially be used as a biomarker in the monitoring of diabetes.

  2. Hypo- and Hyperglycemic Alarms

    PubMed Central

    Howsmon, Daniel; Bequette, B. Wayne

    2015-01-01

    Soon after the discovery that insulin regulates blood glucose by Banting and Best in 1922, the symptoms and risks associated with hypoglycemia became widely recognized. This article reviews devices to warn individuals of impending hypo- and hyperglycemia; biosignals used by these devices include electroencephalography, electrocardiography, skin galvanic resistance, diabetes alert dogs, and continuous glucose monitors (CGMs). While systems based on other technology are increasing in performance and decreasing in size, CGM technology remains the best method for both reactive and predictive alarming of hypo- or hyperglycemia. PMID:25931581

  3. Daily Energy Expenditure, Cardiorespiratory Fitness and Glycaemic Control in People with Type 1 Diabetes

    PubMed Central

    Valletta, John Joseph; Chipperfield, Andrew J.; Clough, Geraldine F.; Byrne, Christopher D.

    2014-01-01

    Objective Encouraging daily physical activity improves cardiorespiratory fitness and many cardiovascular risk factors. However, increasing physical activity often creates a challenge for people with type 1 diabetes, because of difficulties maintaining euglycemia in the face of altered food intake and adjustments to insulin doses. Our aim was to examine the triangular relationship between glucose control measured by continuous glucose monitoring system (CGMS), objective measures of total daily energy expenditure (TEE) recorded by a multi-sensory monitoring device, and cardiorespiratory fitness (CRF), in free-living subjects with type 1 diabetes. Research Design and Methods Twenty-three individuals (12 women) with type 1 diabetes who were free from micro- and macrovascular complications were recruited. TEE and glucose control were monitored simultaneously for up to 12 days, using a multi-sensory device and CGMS respectively. CRF was recorded as V02 max from a maximal treadmill test with the Bruce protocol. Results Subjects (mean±SD) were aged 37±11 years, with BMI = 26.5±5.1 kg.m−2, HbA1c = 7.7±1.3% (61±14 mmol/mol) and V02 max (ml.min−1.kg−1)  = 39.9±8.4 (range 22.4 – 58.6). TEE (36.3±5.5 kcal.kg−1.day−1) was strongly associated with CRF(39.9±8.4 ml.min−1.kg−1) independently of sex (r = 0.63, p<0.01). However, neither TEE (r = −0.20, p = 0.36) nor CRF (r = −0.20, p = 0.39; adjusted for sex), were significantly associated with mean glycaemia measured by CGMS. Conclusion Higher levels of energy expenditure (due to a more active lifestyle) are associated with increased cardiorespiratory fitness, but not necessarily better glycaemic control. Since increased levels of energy expenditure and good glycaemic control are both needed to protect against diabetes-related complications our data suggest they need to be achieved independently. PMID:24826899

  4. Continuous determination of blood glucose in children admitted with malaria in a rural hospital in Mozambique.

    PubMed

    Madrid, Lola; Sitoe, Antonio; Varo, Rosauro; Nhampossa, Tacilta; Lanaspa, Miguel; Nhama, Abel; Acácio, Sozinho; Riaño, Isolina; Casellas, Aina; Bassat, Quique

    2017-05-02

    Hypoglycaemia is a frequent complication among admitted children, particularly in malaria-endemic areas. This study aimed to estimate the occurrence of hypoglycaemia not only upon admission but throughout the first 72 h of hospitalization in children admitted with malaria. A simple pilot study to continuously monitor glycaemia in children aged 0-10 years, admitted with malaria in a rural hospital was conducted in Southern Mozambique by inserting continuous glucose monitors (CGMs) in subcutaneous tissue of the abdominal area, producing glycaemia readings every 5 min. Glucose was continuously monitored during a mean of 48 h, in 74 children. Continuous measurements of blood glucose were available for 72/74 children (97.3%). Sixty-five of them were admitted with density-specific malaria diagnosis criteria (17 severe, 48 uncomplicated). Five children (7.7%) had hypoglycaemia (<54 mg/dL) on admission as detected by routine capillary determination. Analysing the data collected by the CGMs, hypoglycaemia episodes (<54 mg/dL) were detected in 10/65 (15.4%) of the children, of which 7 (10.8%) could be classified as severe (≤45 mg/dL). No risk factors were independently associated with the presence of at least one episode of hypoglycaemia (<54 mg/dL) during hospitalization. Only one death occurred among a normoglycaemic child. All episodes of hypoglycaemia detected by CGMs were subclinical episodes or not perceived by caregivers or clinical staff. Hypoglycaemia beyond admission in children with malaria appears to be much more frequent than what had been previously described. The clinical relevance of these episodes of hypoglycaemia in the medium or long term remains to be determined.

  5. Occurence of adverse events due to continuous glucose monitoring.

    PubMed

    Jadviscokova, Tereza; Fajkusova, Zuzana; Pallayova, Maria; Luza, Jiri; Kuzmina, Galina

    2007-12-01

    Continuous glucose monitoring (CGM) using transcutaneous sensors is becoming a sophisticated method to control and regulate glucose metabolism. The transcutaneous sensor of the CGM system (CGMS Medtronic Minimed, Northridge, CA, USA) is chosen to measure glucose concentration in interstitial fluid up to three days after insertion even though its function remains stable for a longer period. The question arises, which factors really limit the period of sensor insertion without unnecessary risk. The aim of this study was to assess any adverse events occurring in the course of 9 days after the sensor insertion. In a group of 22 healthy volunteers aged 21.8+/-1.30 y (mean +/- SE) a total of 26 sensors was inserted subcutaneously in gluteal or lumbar region for 9 days. Before insertion the site was sprayed with an antiseptic (Cutasept F, Bode Chemie, Hamburg, Germany). Local adverse reactions and disturbances in general condition were examined. In the course of 184 sensor-days, there were only minor local adverse events: hypersensitivity, itching, pain, redness, burning, subcutaneous hemorrhage. Additionally, sleep disturbances, attention deficits, problems related to the CGMS monitor, to adhesive tape and/or sensor were found. None of these resulted in sensor withdrawal. In 12 volunteers (55 %) no complications were observed. The sensor function measured according to electrical signals (ISIG) failed (always on day 1-2) in 4 cases (16 %). The present FDA approved 3-day insertion period for Medtronic transcutaneous sensor does not seem to limit its use and appears to be worth a careful revision.

  6. Glucose sensor evaluation of glycemic instability in pediatric type 1 diabetes mellitus.

    PubMed

    Alemzadeh, Ramin; Loppnow, Cindy; Parton, Elaine; Kirby, Midge

    2003-01-01

    Maintaining blood glucose (BG) levels within the target range can be an elusive goal in children with type 1 diabetes mellitus (DM). To identify factor(s) that may contribute to glycemic instability, we analyzed the Continuous Glucose Monitoring System (CGMS) (Medtronic MiniMed, Northridge, CA) profiles of a group of children with type 1 DM and a history of frequent BG fluctuations and hypoglycemia. A total of 30 (17 girls, 13 boys) pediatric patients with a history of frequent BG fluctuations and hypoglycemia (mean age, 10.5 +/- 0.7 years; duration, 5.0 +/- 0.6 years), on three to four injections of insulin daily or insulin pump therapy, were evaluated by the CGMS. The mean BG (MBG), absolute means of daily differences (MODD), mean amplitude of glycemic excursion (MAGE), and number of hypoglycemic events (BG <60 mg/dL) for 48 h were calculated in each patient. There was a significant correlation between MBG and glycosylated hemoglobin (HbA1c) (r(2) = 0.22, p < 0.009). There was also a significant correlation between severity of lipohypertrophy and glycemic control (HbA1c) (r(2) = 0.20, p < 0.01). The MODD values had a positive correlation with the severity of injection site lipohypertrophy (r(2) = 0.37, p < 0.0003). The MAGE values had a positive correlation with bolus:basal insulin ratio (r(2) = 0.22, p < 0.009) and number of hypoglycemic events (r(2) = 0.21, p < 0.008), independent of age, MBG, and glycemic control. The 48-h CGMS profile can help characterize day-to-day and within-day BG variability and identify factors influencing glycemic instability in pediatric type 1 DM.

  7. Continuous glucose monitoring, oral glucose tolerance, and insulin - glucose parameters in adolescents with simple obesity.

    PubMed

    El Awwa, A; Soliman, A; Al-Ali, M; Yassin, M; De Sanctis, V

    2012-09-01

    In obese adolescents pancreatic beta-cells may not be able to cope with insulin resistance leading to hyperglycemia and type2 diabetes (T2DM To assess oral glucose tolerance, 72-h continuous blood glucose concentrations (CGM) and calculate homeostatic model assessment (HOMA), and the quantitative insulin sensitivity check index (QUICKI) in 13 adolescents with simple obesity (BMI SDS=4 ± 1.06). OGTT performed in 13 obese adolescents (13.47 ± 3 years) revealed 3 cases (23%) with impaired fasting glucose (IFG: fasting glucose >5.6 mmol/L), 4 cases (30%) with impaired glucose tolerance (IGT: 2h blood glucose >7.8 <11.1 mmol/L), and none with diabetes. Using the continuous glucose monitoring system ( CGMS), IFG was detected in 4 cases, the maximum serum blood glucose (BG : 2h or more after meal) was >7.8 and <11.1 mmol/L (IGT) in 9 children (69%) and >11.1 mmol/L (diabetes) in one case (7.6%). Five cases had a minimum BG recorded of <2.7 mmol/L (hypoglycemia). No glycemic abnormality was detected using HbA1C (5.7 ± 0.3%). 11/13 patients had HOMA values >2.6 and QUICKI values <0.35 denoting insulin resistance. Beta cell mass percent (B %) = 200 ± 94.8% and insulin sensitivity values (IS)=50.4 ± 45.5% denoted insulin resistance with hyper-insulinaemia and preserved beta cell mass. In obese adolescents, CGMS is superior to OGTT and HbA1C in detecting glycemic abnormalities, which appears to be secondary to insulin resistance.

  8. A Promising Solution to Enhance the Sensocompatibility of Biosensors in Continuous Glucose Monitoring Systems

    PubMed Central

    van den Bosch, Edith E.M.; de Bont, Nik H.M.; Qiu, Jun; Gelling, Onko-Jan

    2013-01-01

    Background Continuous glucose monitors (CGMs) measure glucose in real time, making it possible to improve glycemic control. A promising technique involves glucose sensors implanted in subcutaneous tissue measuring glucose concentration in interstitial fluid. A major drawback of this technique is sensor bioinstability, which can lead to unpredictable drift and reproducibility. The bioinstability is partly due to sensor design but is also affected by naturally occurring subcutaneous inflammations. Applying a nonbiofouling coating to the sensor membrane could be a means to enhancing sensocompatibility. Methods This study evaluates the suitability of a polyethylene-glycol-based coating on sensors in CGMs. Methods used include cross hatch, wet paper rub, paper double rub, bending, hydrophilicity, protein adsorption, bio-compatibility, hemocompatibility, and glucose/oxygen permeability testing. Results Results demonstrate that coating homogeneity, adhesion, integrity, and scratch resistance are good. The coating repels lysozyme and bovine serum albumin, and only a low level of fibrin and blood platelet adsorption to the coating was recorded when testing in whole human blood. Cytotoxicity, irritation, sensitization, and hemolysis were assessed, and levels suggested good biocompatibility of the coating in subcutaneous tissue. Finally, it was shown that the coating can be applied to cellulose acetate membranes of different porosity without changing their permeability for glucose and oxygen. Conclusions These results suggest that the mechanical properties of the coating are sufficient for the given application, that the coating is effective in preventing protein adsorption and blood clot formation on the sensor surface, and that the coating can be applied to membranes without hindering their glucose and oxygen transport. PMID:23567005

  9. Subcutaneous glucagon infusion and continuous glucose monitoring enable effective management of hypoglycemia in a patient with IGF-2-producing hemangiopericytoma.

    PubMed

    Buras, Eric D; Weatherup, Emily; Wyckoff, Jennifer

    2018-01-01

    Ectopic insulin-like growth factor (IGF)-2 production is a rare complication of an array of epithelial and mesenchymal tumors, and can clinically manifest as life-threatening hypoglycemia. A 49-year-old woman with 13-year history of metastatic hemangiopericytoma, previously treated with multiple rounds of chemotherapy and palliative radiation, presented to the emergency department after a hypoglycemic seizure. On arrival, glucose was 18 mg/dL (1.0 mmol/L) and required continuous dextrose infusion for maintenance within normal limits. Insulin was <2.0 μU/mL, C-peptide 0.1 ng/mL, and beta-hydroxybutyrate <0.2 mmol/L. Random cortisol was 21 μg/dL; sulfonylurea screen, and insulin antibodies were negative. IGF-2 level was 1320 ng/mL; IGF-1 was within normal limits and IGF binding protein (BP)-3 suppressed. Dexamethasone, started at 6 mg twice daily, allowed discontinuation of the glucose infusion. Given concern for nocturnal hypoglycemia, and patient interest in steroid-sparing anti-hypoglycemic regimen, she was also started on overnight continuous subcutaneous glucagon infusion via insulin pump. She was discharged with instructions to maintain a diet high in complex carbohydrates during the day, while utilizing glucagon pump at night. She was also started on continuous glucose monitoring system (CGMS) with an alarm to warn of hypoglycemia. Glucagon infusion rate was later titrated based on CGMS readings. Abdominal CT revealed increasing size of a right upper quadrant mass not previously subjected to radiotherapy. After radiation to this area, hypoglycemia improved, allowing further glucagon titration. In parallel, IGF-2 level declined to 380 ng/mL. Ectopic IGF-2 production is a rare but often fatal complication of many cancers, and should be considered on the differential diagnosis in patients with malignancy and unexplained hypoglycemia. Once hypoglycemia is diagnosed, patients often have end-stage disease. While treatment of the causative tumor is the only definitive intervention, anti-hypoglycemia therapy is a life-saving, temporizing measure. In this case, the patient attained euglycemia and survived 3 months after presentation before ultimately succumbing to other malignancy-related complications. Given efficacy in management of hypoglycemia while awaiting definitive tumor-directed therapy, we submit nighttime subcutaneous glucagon infusion and CGMS are valuable additions to the physician's armamentarium in managing this condition.

  10. Preparation of three-dimensional macroporous chitosan-gelatin B microspheres and HepG2-cell culture.

    PubMed

    Huang, Fang; Cui, Long; Peng, Cheng-Hong; Wu, Xu-Bo; Han, Bao-San; Dong, Ya-Dong

    2016-12-01

    Chitosan-gelatin B microspheres with an open, interconnected, highly macroporous (100-200 µm) structure were prepared via a three-step protocol combining freeze-drying with an electrostatic and ionic cross-linking method. Saturated tripolyphosphate ethanol solution (85% ethanol) was chosen as the crosslinking agent to prevent destruction of the porous structure and to improve the biostability of the chitosan-gelatin B microspheres, with N-(3-dimethylaminopropyl)-N'-ethyl-carbodiimide/N-hydroxysuccinimide as a second crosslinking agent to react with gelatin A and fixed chitosan-gelatin B microspheres to attain improved biocompatibility. Water absorption of the three-dimensional macroporous chitosan-gelatin B microspheres (3D-P-CGMs) was 12.84, with a porosity of 85.45%. In vitro lysozyme degradation after 1, 3, 5, 7, 10, 14, and 21 days showed improved biodegradation in the 3D-P-CGMs. The morphology of human hepatoma cell lines (HepG2 cells) cultured on the 3D-P-CGMs was spherical, unlike that of cells cultured under traditional two-dimensional conditions. Scanning electron microscopy and paraffin sections were used to confirm the porous structure of the 3D-P-CGMs. HepG2 cells were able to migrate inside through the pore. Cell proliferation and levels of albumin and lactate dehydrogenase suggested that the 3D-P-CGMs could provide a larger specific surface area and an appropriate microenvironment for cell growth and survival. Hence, the 3D-P-CGMs are eminently suitable as macroporous scaffolds for cell cultures in tissue engineering and cell carrier studies. Copyright © 2014 John Wiley & Sons, Ltd. Copyright © 2014 John Wiley & Sons, Ltd.

  11. Recurrent nocturnal hypoglycaemia as a cause of morning fatigue in treated Addison's disease--favourable response to dietary management: a case report.

    PubMed

    Petersen, Kristina S; Rushworth, R Louise; Clifton, Peter M; Torpy, David J

    2015-10-24

    Addison's disease, or primary adrenal insufficiency, is often associated with reduced well-being and fatigue despite use of currently recommended adrenal hormone replacement. Hypoglycaemia is a known manifestation of glucocorticoid deficiency, but is generally considered rare in adults and not relevant to troubling ongoing symptoms in patients with Addison's disease. A 43 year old woman with a three year history of Addison's disease complained of severe morning fatigue and headaches, despite standard glucocorticoid replacement therapy in the form of thrice daily hydrocortisone and mineralocorticoid replacement with fludrocortisone. Alternative glucocorticoid replacement regimens and the addition of dehydroepiandrosterone replacement therapy had no effect. Nocturnal hypoglycaemia was suspected and a 4-day continuous glucose monitor system (CGMS) revealed hypoglycaemia (interstitial glucose < 2.2 mmol/L) between 0200-0400 h on 3 of 4 days. The patient was counselled to take an evening snack designed to ensure slow absorption of ingested carbohydrates. Nocturnal hypoglycaemia was then absent on follow up CGMS assessment. The patient noted a marked symptomatic improvement in morning symptoms, but with persistent fatigue during the day. Currently, the best strategy for control of non-specific symptoms in treated Addison's disease is unknown, but it may be that investigation for hypoglycaemia and treatment, where necessary, could assist some sufferers to achieve improved wellbeing. A systematic study of this phenomenon in Addison's disease is required.

  12. Extended Prandial Glycemic Profiles of Foods as Assessed Using Continuous Glucose Monitoring Enhance the Power of the 120-Minute Glycemic Index

    PubMed Central

    Chlup, Rudolf; Peterson, Karolina; Zapletalová, Jana; Kudlová, Pavla; Sečkař, Pavel

    2010-01-01

    Background The glycemic index (GI) is routinely measured 120 minutes after food intake (GI120). The purpose of this prospective open label study was to assess (1) the dynamics of glycemia over the 210 minutes following food consumption and (2) the evolution of GIs based on 120-, 150-, 180-, and 210-minute glycemic profiles. Method Twenty healthy subjects (mean ± SE; 21.9 ± 1.39 years of age; body mass index 23.6 ± 0.63 kg/m2; 7 men and 13 women) completed the study. Each subject consumed 10 different foods with known GI120 on three separate occasions at four different times of day according to a defined meal plan over a 9-day period; 32 meals were evaluated. The GIs for intervals of 120, 150, 180 and 210 minutes after food consumption were determined using a continuous glucose monitoring system (CGMS) to measure glycemia. The Wilcoxon signed-rank test was applied to compare the GIs. Results Glycemia returned to baseline within 120 minutes for honey and tomato soup; within 210 minutes for white bread, choco-rice cookies, fish and potatoes, wafers, and meat ravioli with cheese; and later for dark chocolate, apricot dumplings, and choco-wheat cookies. The extended GIs were higher than the respective GI120s in eight of the foods. Conclusions The 120-minute glycemic index fails to fully account for changes in glycemia after ingestion of a mixed meal because glycemia remains above baseline for a longer period. The CGMS is a convenient method to determine the glucose response/GIs over intervals extended up to 210 minutes, which is adequate time for the absorption of most foods. PMID:20513328

  13. Reasoning with Causal Cycles

    ERIC Educational Resources Information Center

    Rehder, Bob

    2017-01-01

    This article assesses how people reason with categories whose features are related in causal cycles. Whereas models based on causal graphical models (CGMs) have enjoyed success modeling category-based judgments as well as a number of other cognitive phenomena, CGMs are only able to represent causal structures that are acyclic. A number of new…

  14. A portable measuring system for a competitive binding glucose biosensor

    NASA Astrophysics Data System (ADS)

    Colvin, Lydia E.; Means, A. Kristen; Grunlan, Melissa A.; Coté, Gerard L.

    2018-02-01

    Central to minimizing the long- and short-term complications associated with diabetes is careful monitoring and maintenance of blood glucose at normal levels. Towards replacing conventionally used finger-prick glucose testing, indwelling continuous glucose monitors (CGMs) based on amperometric electrodes have been introduced to the market. Envisioned to lead to a CGM with an increased lifetime, we report herein a fluorescently-labeled competitive binding assay contained within a hydrogel membrane whose glucose response is measured via a novel portable system. The optical system design included a laser source, bifurcated fiber, laser filter and simple fiber coupled spectrometer to obtain the change in FRET pair ratio of the assay. Glucose response of the assay in free solution was measured using this system across the physiologic range (0-200 mg/dL). The FRET pair ratio signal was seen to increase with glucose and the standard error of calibration was 22.42 mg/dL with a MARD value of 14.85%. When the assay was contained within the hydrogel membrane's central cavity and similarly analyzed, the standard error increased but the assay maintained its reversibility.

  15. Drought-related vulnerability and risk assessment of groundwater in Belgium: estimation of the groundwater recharge and crop yield vulnerability with the B-CGMS

    NASA Astrophysics Data System (ADS)

    Jacquemin, Ingrid; Verbeiren, Boud; Vanderhaegen, Sven; Canters, Frank; Vermeiren, Karolien; Engelen, Guy; Huysmans, Marijke; Batelaan, Okke; Tychon, Bernard

    2016-04-01

    Due to common belief that regions under temperate climate are not affected by (meteorological and groundwater) drought, these events and their impacts remain poorly studied: in the GroWaDRISK, we propose to take stock of this question. We aim at providing a better understanding of the influencing factors (land use and land cover changes, water demand and climate) and the drought-related impacts on the environment, water supply and agriculture. The study area is located in the North-East of Belgium, corresponding approximatively to the Dijle and Demer catchments. To establish an overview of the groundwater situation, we assess the system input: the recharge. To achieve this goal, two models, B-CGMS and WetSpass are used to evaluate the recharge, respectively, over agricultural land and over the remaining areas, as a function of climate and for various land uses and land covers. B-CGMS, which is an adapted version for Belgium of the European Crop Growth Monitoring System, is used for assessing water recharge at a daily timestep and under different agricultural lands: arable land (winter wheat, maize...), orchards, horticulture and floriculture and for grassland. B-CGMS is designed to foresee crop yield and obviously it studies the impact of drought on crop yield and raises issues for the potential need of irrigation. For both yields and water requirements, the model proposes a potential mode, driven by temperature and solar radiation, and a water-limited mode for which water availability can limit crop growth. By this way, we can identify where and when water consumption and yield are not optimal, in addition to the Crop Water Stress Index. This index is calculated for a given crop, as the number of days affected by water stress during the growth sensitive period. Both recharge and crop yield are assessed for the current situation (1980 - 2012), taking into account the changing land use/land cover, in terms of areas and localization of the agricultural land and where the proportion of the different crops had considerably evolved through time (e.g., increase of grain maize and potatoes while winter cereals decrease). The preliminary results of the recharge lead to an average value in the area showing a significant negative trend, in both simulations with fixed (base = 1980) and changing land cover. In the same time, we could observe an increasing number of water stress periods, especially for maize, one of the main crops in the area. Finally, a preliminary test will be presented for the horizon 2040, for which we use meteorological time series (for high and low hydrologic impacts) given by the CCI-HYDR Perturbation Tool (Ntegeka V. and Willems P., 2009). This preliminary test aims to (1) evaluate the amplitude of the potential recharge deficit and, (2) especially, to define vulnerability zones, affected by frequent water stress, in connection with irrigation needs which could possibly increase the groundwater extraction.

  16. Modeling the Error of the Medtronic Paradigm Veo Enlite Glucose Sensor.

    PubMed

    Biagi, Lyvia; Ramkissoon, Charrise M; Facchinetti, Andrea; Leal, Yenny; Vehi, Josep

    2017-06-12

    Continuous glucose monitors (CGMs) are prone to inaccuracy due to time lags, sensor drift, calibration errors, and measurement noise. The aim of this study is to derive the model of the error of the second generation Medtronic Paradigm Veo Enlite (ENL) sensor and compare it with the Dexcom SEVEN PLUS (7P), G4 PLATINUM (G4P), and advanced G4 for Artificial Pancreas studies (G4AP) systems. An enhanced methodology to a previously employed technique was utilized to dissect the sensor error into several components. The dataset used included 37 inpatient sessions in 10 subjects with type 1 diabetes (T1D), in which CGMs were worn in parallel and blood glucose (BG) samples were analyzed every 15 ± 5 min Calibration error and sensor drift of the ENL sensor was best described by a linear relationship related to the gain and offset. The mean time lag estimated by the model is 9.4 ± 6.5 min. The overall average mean absolute relative difference (MARD) of the ENL sensor was 11.68 ± 5.07% Calibration error had the highest contribution to total error in the ENL sensor. This was also reported in the 7P, G4P, and G4AP. The model of the ENL sensor error will be useful to test the in silico performance of CGM-based applications, i.e., the artificial pancreas, employing this kind of sensor.

  17. Continuous glucose monitoring: quality of hypoglycaemia detection.

    PubMed

    Zijlstra, E; Heise, T; Nosek, L; Heinemann, L; Heckermann, S

    2013-02-01

    To evaluate the accuracy of a (widely used) continuous glucose monitoring (CGM)-system and its ability to detect hypoglycaemic events. A total of 18 patients with type 1 diabetes mellitus used continuous glucose monitoring (Guardian REAL-Time CGMS) during two 9-day in-house periods. A hypoglycaemic threshold alarm alerted patients to sensor readings <70 mg/dl. Continuous glucose monitoring sensor readings were compared to laboratory reference measurements taken every 4 h and in case of a hypoglycaemic alarm. A total of 2317 paired data points were evaluated. Overall, the mean absolute relative difference (MARD) was 16.7%. The percentage of data points in the clinically accurate or acceptable Clarke Error Grid zones A + B was 94.6%. In the hypoglycaemic range, accuracy worsened (MARD 38.8%) leading to a failure to detect more than half of the true hypoglycaemic events (sensitivity 37.5%). Furthermore, more than half of the alarms that warn patients for hypoglycaemia were false (false alert rate 53.3%). Above the low alert threshold, the sensor confirmed 2077 of 2182 reference values (specificity 95.2%). Patients using continuous glucose monitoring should be aware of its limitation to accurately detect hypoglycaemia. © 2012 Blackwell Publishing Ltd.

  18. Continuous glucose monitors: current status and future developments.

    PubMed

    Lane, Jennifer E; Shivers, Joseph P; Zisser, Howard

    2013-04-01

    Advances in diabetes technologies allow patients to manage their diabetes with greater precision and flexibility. Many recent studies show that continuous glucose monitors (CGMs) can be used to tighten glycemic control safely and to ease certain burdens of diabetes self-management. The following summary reflects the most recent findings in CGM and provides an overall review of who would most benefit from CGM use. Benefits of CGM may vary based on age, type of diabetes, pregnancy, health, sleep, or heart rate. Accuracy and reliability are critical in current uses of CGM and especially for new and future systems that automate insulin partially (e.g., low glucose suspend) or entirely (e.g., 'fully closed-loop' artificial pancreas). Clinicians are simultaneously testing available products in new patient groups such as the critically ill and type 2 diabetes patients not using mealtime insulin. In a widening set of circumstances, use of CGM has been shown to promote safer and more effective glycemic control than self-monitoring of blood glucose. Imperfections remain in certain scenarios such as hypoglycemia and in certain populations such as young children. Ongoing research on sensors and calibration software should translate to better systems.

  19. Transcriptome profiling and cataloging differential gene expression in floral buds of fertile and sterile lines of cotton (Gossypium hirsutum L.).

    PubMed

    Hamid, Rasmieh; Tomar, Rukam S; Marashi, Hassan; Shafaroudi, Saeid Malekzadeh; Golakiya, Balaji A; Mohsenpour, Motahhareh

    2018-06-20

    Cytoplasmic Male Sterility is maternally inherited trait in plants, characterized by failure to produce functional pollen during anther development. Anther development is modulated through the interaction of nuclear and mitochondrial genes. In the present study, differential gene expression of floral buds at the sporogenous stage (SS) and microsporocyte stage (MS) between CGMS and its fertile maintainer line of cotton plants was studied. A total of 320 significantly differentially expressed genes, including 20 down-regulated and 37 up-regulated in CGMS comparing with its maintainer line at the SS stage, as well as and 89 down-regulated and 4 up-regulated in CGMS compared to the fertile line at MS stage. Comparing the two stages in the same line, there were 6 down-regulated differentially expressed genes only induced in CGMS and 9 up-regulated differentially expressed gene only induced in its maintainer. GO analysis revealed essential genes responsible for pollen development, and cytoskeleton category show differential expression between the fertile and CGMS lines. Validation studies by qRT-PCR shows concordance with RNA-seq result. A set of novel SSRs identified in this study can be used in evaluating genetic relationships among cultivars, QTL mapping, and marker-assisted breeding. We reported aberrant expression of genes related to pollen exine formation, and synthesis of pectin lyase, myosine heavy chain, tubulin, actin-beta, heat shock protein and myeloblastosis (MYB) protein as targets for CMS in cotton. The results of this study contribute to basic information for future screening of genes and identification of molecular portraits responsible for CMS as well as to elucidate molecular mechanisms that lead to CMS in cotton. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. A higher-complex carbohydrate diet in gestational diabetes mellitus achieves glucose targets and lowers postprandial lipids: a randomized crossover study.

    PubMed

    Hernandez, Teri L; Van Pelt, Rachael E; Anderson, Molly A; Daniels, Linda J; West, Nancy A; Donahoo, William T; Friedman, Jacob E; Barbour, Linda A

    2014-01-01

    The conventional diet approach to gestational diabetes mellitus (GDM) advocates carbohydrate restriction, resulting in higher fat (HF), also a substrate for fetal fat accretion and associated with maternal insulin resistance. Consequently, there is no consensus about the ideal GDM diet. We hypothesized that, compared with a conventional, lower-carbohydrate/HF diet (40% carbohydrate/45% fat/15% protein), consumption of a higher-complex carbohydrate (HCC)/lower-fat (LF) Choosing Healthy Options in Carbohydrate Energy (CHOICE) diet (60/25/15%) would result in 24-h glucose area under the curve (AUC) profiles within therapeutic targets and lower postprandial lipids. Using a randomized, crossover design, we provided 16 GDM women (BMI 34 ± 1 kg/m2) with two 3-day isocaloric diets at 31 ± 0.5 weeks (washout between diets) and performed continuous glucose monitoring. On day 4 of each diet, we determined postprandial (5 h) glucose, insulin, triglycerides (TGs), and free fatty acids (FFAs) following a controlled breakfast meal. There were no between-diet differences for fasting or mean nocturnal glucose, but 24-h AUC was slightly higher (∼6%) on the HCC/LF CHOICE diet (P = 0.02). The continuous glucose monitoring system (CGMS) revealed modestly higher 1- and 2-h postprandial glucose on CHOICE (1 h, 115 ± 2 vs. 107 ± 3 mg/dL, P ≤ 0.01; 2 h, 106 ± 3 vs. 97 ± 3 mg/dL, P = 0.001) but well below current targets. After breakfast, 5-h glucose and insulin AUCs were slightly higher (P < 0.05), TG AUC was no different, but the FFA AUC was significantly lower (∼19%; P ≤ 0.01) on the CHOICE diet. This highly controlled study randomizing isocaloric diets and using a CGMS is the first to show that liberalizing complex carbohydrates and reducing fat still achieved glycemia below current treatment targets and lower postprandial FFAs. This diet strategy may have important implications for preventing macrosomia.

  1. Coexistence of insulin resistance and increased glucose tolerance in pregnant rats: a physiological mechanism for glucose maintenance.

    PubMed

    Carrara, Marcia Aparecida; Batista, Márcia Regina; Saruhashi, Tiago Ribeiro; Felisberto, Antonio Machado; Guilhermetti, Marcio; Bazotte, Roberto Barbosa

    2012-06-06

    The contribution of insulin resistance (IR) and glucose tolerance to the maintenance of blood glucose levels in non diabetic pregnant Wistar rats (PWR) was investigated. PWR were submitted to conventional insulin tolerance test (ITT) and glucose tolerance test (GTT) using blood sample collected 0, 10 and 60 min after intraperitoneal insulin (1 U/kg) or oral (gavage) glucose (1g/kg) administration. Moreover, ITT, GTT and the kinetics of glucose concentration changes in the fed and fasted states were evaluated with a real-time continuous glucose monitoring system (RT-CGMS) technique. Furthermore, the contribution of the liver glucose production was investigated. Conventional ITT and GTT at 0, 7, 14 and 20 days of pregnancy revealed increased IR and glucose tolerance after 20 days of pregnancy. Thus, this period of pregnancy was used to investigate the kinetics of glucose changes with the RT-CGMS technique. PWR (day 20) exhibited a lower (p<0.05) glucose concentration in the fed state. In addition, we observed IR and increased glucose tolerance in the fed state (PWR-day 20 vs. day 0). Furthermore, our data from glycogenolysis and gluconeogenesis suggested that the liver glucose production did not contribute to these changes in insulin sensitivity and/or glucose tolerance during late pregnancy. In contrast to the general view that IR is a pathological process associated with gestational diabetes, a certain degree of IR may represent an important physiological mechanism for blood glucose maintenance during fasting. Copyright © 2012 Elsevier Inc. All rights reserved.

  2. Wireless connection of continuous glucose monitoring system to the electronic patient record

    NASA Astrophysics Data System (ADS)

    Murakami, Alexandre; Gutierrez, Marco A.; Lage, Silvia G.; Rebelo, Marina S.; Granja, Luiz A. R.; Ramires, Jose A. F.

    2005-04-01

    The control of blood sugar level (BSL) at near-normal levels has been documented to reduce both acute and chronic complications of diabetes mellitus. Recent studies suggested, the reduction of mortality in a surgical intensive care unit (ICU), when the BSL are maintained at normal levels. Despite of the benefits appointed by these and others clinical studies, the strict BSL control in critically ill patients suffers from some difficulties: a) medical staff need to measure and control the patient"s BSL using blood sample at least every hour. This is a complex and time consuming task; b) the inaccuracy of standard capillary glucose monitoring (fingerstick) in hypotensive patients and, if frequently used to sample arterial or venous blood, may lead to excess phlebotomy; c) there is no validated procedure for continuously monitoring of BSL levels. This study used the MiniMed CGMS in ill patients at ICU to send, in real-time, BSL values to a Web-Based Electronic Patient Record. The BSL values are parsed and delivered through a wireless network as an HL7 message. The HL7 messages with BSL values are collected, stored into the Electronic Patient Record and presented into a bed-side monitor at the ICU together with other relevant patient information.

  3. Fire Monitoring from the New Generation of US Polar and Geostationary Satellites

    NASA Astrophysics Data System (ADS)

    Csiszar, I.; Justice, C. O.; Prins, E.; Schroeder, W.; Schmidt, C.; Giglio, L.

    2012-04-01

    Sensors on the new generation of US operational environmental satellites will provide measurements suitable for active fire detection and characterization. The NPOESS Preparatory Project (NPP) satellite, launched on October 28, 2011, carries the Visible Infrared Imager Radiometer Suite (VIIRS), which is expected to continue the active fire data record from the Moderate Resolution Imaging Spectroradiometer (MODIS) on the NASA Earth Observing System Terra and Aqua Satellites. Early evaluation of the VIIRS active fire product, including comparison to near-simultaneous MODIS data, is underway. The new generation of Geostationary Operational Environmental Satellite (GOES) series, starting with GOES-R to be launched in 2015, will carry the Advanced Baseline Imager (ABI), providing higher spatial and temporal resolution than the current GOES imager. The ABI will also include a dedicated band to provide radiance observations over a wider dynamic range to detect and characterize hot targets. In this presentation we discuss details of the monitoring capabilities from both VIIRS and ABI and the current status of the corresponding algorithm development and testing efforts. An integral part of this activity is explicit product validation, utilizing high resolution satellite and airborne imagery as reference data. The new capabilities also represent challenges to establish continuity with data records from heritage missions, and to coordinate compatible international missions towards a global multi-platform fire monitoring system. These objectives are pursued by the Fire Mapping and Monitoring Implementation Team of the Global Observation of Forest and Land Cover Dynamics (GOFC-GOLD) program, which also provides coordinated contribution to relevant initiatives by the Committee on Earth Observation Satellites (CEOS), the Coordination Group for Meteorological Satellites (CGMS) and the Global Climate Observing System (GCOS).

  4. [Continuous glucose monitoring with type 1 diabetes mellitus].

    PubMed

    López-Siguero, J P; García Arias, M J; del Pino de la Fuente, A; Moreno Molina, J A

    2003-03-01

    Appropriate metabolic control of children with type 1 diabetes mellitus (DM) is based on frequent measurements of capillary glycemia. However, this method offers only partial information on fluctuations in glycemia during the day, while episodes of postprandial hyperglycemia and hypoglycemia, mainly nocturnal, go unnoticed. To analyze pre- and postprandial blood glucose levels, as well as the presence and duration of hypoglycemic episodes in diabetic children aged more than 8 years old with more than one year of disease duration. Seventeen patients of both sexes (mean age: 12 years old) with type 1 DM were monitored with the continuous glucose monitoring system (CGMS) during working days. Maximum values of pre- and postprandial glucose (1-3 hours after breakfast, lunch and dinner) were registered. Data were downloaded with a Com-station. The mean duration of sensor-wearing was 2.97 days. Pre- and postprandial values were high: mean preprandial values were between 144.9 and 160.5 mg % and mean postprandial values were between 230.4 and 248.8 mg %. The mean number of hypoglycemic episodes detected with the sensor was 4.9 compared with 1.8 detected with the glucometer (p < 0.05). Episodes of mainly nocturnal asymptomatic hypoglycemia were detected with a mean duration of 145 minutes during the night and 75 minutes during the day. The use of continuous subcutaneous glucose monitoring demonstrates that glycemic objectives are not achieved by conventional insulin therapy. It also shows that there are a high number of hypoglycemic episodes, most of which are asymptomatic.

  5. Performance of Cleared Blood Glucose Monitors.

    PubMed

    Klonoff, David C; Prahalad, Priya

    2015-07-01

    Cleared blood glucose monitor (BGM) systems do not always perform as accurately for users as they did to become cleared. We performed a literature review of recent publications between 2010 and 2014 that present data about the frequency of inaccurate performance using ISO 15197 2003 and ISO 15197 2013 as target standards. We performed an additional literature review of publications that present data about the clinical and economic risks of inaccurate BGMs for making treatment decisions or calibrating continuous glucose monitors (CGMs). We found 11 publications describing performance of 98 unique BGM systems. 53 of these 98 (54%) systems met ISO 15197 2003 and 31 of the 98 (32%) tested systems met ISO 15197 2013 analytical accuracy standards in all studies in which they were evaluated. Of the tested systems, 33 were identified by us as FDA-cleared. Among these FDA-cleared BGM systems, 24 out of 32 (75%) met ISO 15197 2003 and 15 out of 31 (48.3%) met ISO 15197 2013 in all studies in which they were evaluated. Among the non-FDA-cleared BGM systems, 29 of 65 (45%) met ISO 15197 2003 and 15 out of 65 (23%) met ISO 15197 2013 in all studies in which they were evaluated. It is more likely that an FDA-cleared BGM system, compared to a non-FDA-cleared BGM system, will perform according to ISO 15197 2003 (χ(2) = 6.2, df = 3, P = 0.04) and ISO 15197 2013 (χ(2) = 11.4, df = 3, P = 0.003). We identified 7 articles about clinical risks and 3 articles about economic risks of inaccurate BGMs. We conclude that a significant proportion of cleared BGMs do not perform at the level for which they were cleared or according to international standards of accuracy. Such poor performance leads to adverse clinical and economic consequences. © 2015 Diabetes Technology Society.

  6. Diabetic Coma

    MedlinePlus

    ... unawareness). CGMs are devices that use a small sensor inserted underneath the skin to track trends in ... may help you control your glucose better. Drink alcohol with caution. Because alcohol can have an unpredictable ...

  7. Do high blood glucose peaks contribute to higher HbA1c? Results from repeated continuous glucose measurements in children.

    PubMed

    Ulf, Samuelsson; Ragnar, Hanas; Arne, Whiss Per; Johnny, Ludvigsson

    2008-08-01

    HbA1c levels are influenced by the glycemic control of previous 2-3 months. Sometimes patients have surprisingly low HbA1c in spite of many correctly measured high blood glucose values, which is difficult to explain. As glucose sensors give an objective picture based on glucose readings several times per minute over 24 hours, we used the area under the curve (AUC) of such subcutaneous glucose profiles to evaluate their relationship with HbA1c. Thirty-two patients were randomized into two study arms, one open and the other blinded. Both arms had 8 pump users and 8 patients with multiple daily injections (MDI). After three months the two arms crossed over. Both study arms wore a continuous glucose monitoring system (CGMS) for 3 days every 2 weeks. HbA1c was determined before and after each 3-month study period. There was no relationship between HbA1c and s.c. glucose AUC or between HbA1c and the number of peaks >15.0 mmol/L when all CGMS profiles during the 6 months were taken together. Children on MDI showed a positive relationship between HbA1c and AUC (P<0.01) as well as the number of peaks (P<0.01). Children with a negative relationship between HbA1c and AUC generally had fewer fluctuations in blood glucose values, whereas children with a positive relationship had wide fluctuations. between s.c. glucose AUC and HbA1c, the results indicate that wide blood glucose fluctuations may be related to high HbA1c values. Therefore, complications and therapeutic interventions should aim at reducing such fluctuations. Although there was no relationship between s.c. glucose AUC and HbA1c, the results indicate that wide blood glucose fluctuations may be related to high HbA1c values. Therefore, complications and therapeutic interventions should aim at reducing such fluctuations.

  8. One Bout of Exercise Alters Free-Living Postprandial Glycemia in Type 2 Diabetes

    PubMed Central

    Oberlin, Douglas J.; Mikus, Catherine R.; Kearney, Monica L.; Hinton, Pamela S.; Manrique, Camila; Leidy, Heather J.; Kanaley, Jill A.; Rector, R. Scott; Thyfault, John P.

    2015-01-01

    PURPOSE Elevated postprandial glycemic excursions (PPG) are significant risk factors for cardiovascular disease in type 2 diabetes patients. Here we tested if and for how many meals a single bout of exercise would reduce PPG responses to subsequent meals in type 2 diabetes (T2D) patients using continuous glucose monitors (CGMS). METHODS We recruited 9 sedentary (<30 minutes/week of exercise) individuals with T2D (BMI: 36.0 ± 1.1 kg/m2; age 60.3 ± 1.0 years; HbA1c: 6.3 ± 0.2 %). The subjects consumed a eucaloric diet (51% carbohydrate, 31% fat, 18% protein) consisting of 3 meals, identical in composition, over a 2-day period while wearing CGMS in two different conditions (exercise (EX; one 60 minute bout at 60-75% of heart rate reserve performed prior to breakfast) vs. a sedentary (SED) condition). We quantified 24-h average glucose, PPG-AUC (4 h glucose AUC following meals) and PPG-2 h (2 hour post-prandial glucose). RESULTS EX significantly reduced average [glucose] during the first 24 hour period (p=0.03). EX caused a reduction in PPG-AUC (p=0.02) for all of the meals over the two days (main effect between conditions). Comparison between the EX and SED conditions at each meal revealed that EX reduced PPG-AUC following the second meal of day 1 (lunch) (p=0.04). PPG-2 h was not significantly different between EX and SED. CONCLUSION Although a single EX bout does lower 24-h average [glucose], it only significantly lowered PPG-AUC at the second meal following the bout suggesting that daily exercise may be needed to most effectively improve PPG at the advent of exercise training in T2D patients. PMID:23872939

  9. Steroids in porcine follicular fluid: analysis by HPLC, capillary CG and capillary CG/MS after purification on SEP-PAK C18 and ion exchange chromatography.

    PubMed

    Khalil, M W; Lawson, V

    1983-04-01

    Steroids in porcine follicular fluid have been concentrated by reverse phase chromatography in SEP-PAK C18 and purified further on the cation exchanger SP-Sephadex C-25. Fractionation into unconjugated neutral and phenolic steroids, glucuronides and sulfates was carried out on triethylaminohydroxypropyl Sephadex LH-20 (TEAP-LH-20). The unconjugated neutral fraction was analysed by high pressure liquid chromatography (HPLC) on a C18 radial cartridge 5 mm I.D.; 10 mu, or on a C18 5 mu RESOLVE column, and by capillary gas chromatography (GC) on a 12 M OV-1 cross linked fused silica column. Testosterone, progesterone and androstenedione were the major steroids detected by HPLC monitored at 254 nm, although 17- hydroxy-, 20 alpha-dihydro- and 20 beta-dihydroprogesterone were also present. Pregnenolone, pregnanediol, dehydroepiandrosterone, 17-hydroxypregnenolone and androsterone were detected by capillary CG as their 0-methyloxime trimethylsilyether derivatives. Further confirmation of structure was provided by complete mass spectral data or by selective ion monitoring (SIM).

  10. Integrating Crop Growth Models with Whole Genome Prediction through Approximate Bayesian Computation.

    PubMed

    Technow, Frank; Messina, Carlos D; Totir, L Radu; Cooper, Mark

    2015-01-01

    Genomic selection, enabled by whole genome prediction (WGP) methods, is revolutionizing plant breeding. Existing WGP methods have been shown to deliver accurate predictions in the most common settings, such as prediction of across environment performance for traits with additive gene effects. However, prediction of traits with non-additive gene effects and prediction of genotype by environment interaction (G×E), continues to be challenging. Previous attempts to increase prediction accuracy for these particularly difficult tasks employed prediction methods that are purely statistical in nature. Augmenting the statistical methods with biological knowledge has been largely overlooked thus far. Crop growth models (CGMs) attempt to represent the impact of functional relationships between plant physiology and the environment in the formation of yield and similar output traits of interest. Thus, they can explain the impact of G×E and certain types of non-additive gene effects on the expressed phenotype. Approximate Bayesian computation (ABC), a novel and powerful computational procedure, allows the incorporation of CGMs directly into the estimation of whole genome marker effects in WGP. Here we provide a proof of concept study for this novel approach and demonstrate its use with synthetic data sets. We show that this novel approach can be considerably more accurate than the benchmark WGP method GBLUP in predicting performance in environments represented in the estimation set as well as in previously unobserved environments for traits determined by non-additive gene effects. We conclude that this proof of concept demonstrates that using ABC for incorporating biological knowledge in the form of CGMs into WGP is a very promising and novel approach to improving prediction accuracy for some of the most challenging scenarios in plant breeding and applied genetics.

  11. Integrating Crop Growth Models with Whole Genome Prediction through Approximate Bayesian Computation

    PubMed Central

    Technow, Frank; Messina, Carlos D.; Totir, L. Radu; Cooper, Mark

    2015-01-01

    Genomic selection, enabled by whole genome prediction (WGP) methods, is revolutionizing plant breeding. Existing WGP methods have been shown to deliver accurate predictions in the most common settings, such as prediction of across environment performance for traits with additive gene effects. However, prediction of traits with non-additive gene effects and prediction of genotype by environment interaction (G×E), continues to be challenging. Previous attempts to increase prediction accuracy for these particularly difficult tasks employed prediction methods that are purely statistical in nature. Augmenting the statistical methods with biological knowledge has been largely overlooked thus far. Crop growth models (CGMs) attempt to represent the impact of functional relationships between plant physiology and the environment in the formation of yield and similar output traits of interest. Thus, they can explain the impact of G×E and certain types of non-additive gene effects on the expressed phenotype. Approximate Bayesian computation (ABC), a novel and powerful computational procedure, allows the incorporation of CGMs directly into the estimation of whole genome marker effects in WGP. Here we provide a proof of concept study for this novel approach and demonstrate its use with synthetic data sets. We show that this novel approach can be considerably more accurate than the benchmark WGP method GBLUP in predicting performance in environments represented in the estimation set as well as in previously unobserved environments for traits determined by non-additive gene effects. We conclude that this proof of concept demonstrates that using ABC for incorporating biological knowledge in the form of CGMs into WGP is a very promising and novel approach to improving prediction accuracy for some of the most challenging scenarios in plant breeding and applied genetics. PMID:26121133

  12. Toward Global Harmonization of Derived Cloud Products

    NASA Technical Reports Server (NTRS)

    Wu, Dong L.; Baum, Bryan A.; Choi, Yong-Sang; Foster, Michael J.; Karlsson, Karl-Goeran; Heidinger, Andrew; Poulsen, Caroline; Pavolonis, Michael; Riedi, Jerome; Roebeling, Robert

    2017-01-01

    Formerly known as the Cloud Retrieval Evaluation Workshop (CREW; see the list of acronyms used in this paper below) group (Roebeling et al. 2013, 2015), the International Cloud Working Group (ICWG) was created and endorsed during the 42nd Meeting of CGMS. The CGMS-ICWG provides a forum for space agencies to seek coherent progress in science and applications and also to act as a bridge between space agencies and the cloud remote sensing and applications community. The ICWG plans to serve as a forum to exchange and enhance knowledge on state-of-the-art cloud parameter retrievals algorithms, to stimulate support for training in the use of cloud parameters, and to encourage space agencies and the cloud remote sensing community to share knowledge. The ICWG plans to prepare recommendations to guide the direction of future research-for example, on observing severe weather events or on process studies-and to influence relevant programs of the WMO, WCRP, GCOS, and the space agencies.

  13. Self-Monitoring Using Continuous Glucose Monitors with Real-Time Feedback Improves Exercise Adherence in Individuals with Impaired Blood Glucose: A Pilot Study.

    PubMed

    Bailey, Kaitlyn J; Little, Jonathan P; Jung, Mary E

    2016-03-01

    Exercise helps individuals with prediabetes or type 2 diabetes (T2D) manage their blood glucose (BG); however, exercise adherence in this population is dismal. In this pilot study we tested the efficacy of a self-monitoring group-based intervention using continuous glucose monitors (CGMs) at increasing exercise adherence in individuals with impaired BG. Thirteen participants with prediabetes or T2D were randomized to an 8-week standard care exercise program (CON condition) (n = 7) or self-monitoring exercise intervention (SM condition) (n = 6). Participants in the SM condition were taught how to self-monitor their exercise and BG, to goal set, and to use CGM to observe how exercise influences BG. We hypothesized that compared with the CON condition, using a real-time CGM would facilitate self-monitoring behavior, resulting in increased exercise adherence. Repeated-measures analysis of variance revealed significant Condition × Time interactions for self-monitoring (P < 0.01), goal setting (P = 0.01), and self-efficacy to self-monitor (P = 0.01), such that the SM condition showed greater increases in these outcomes immediately after the program and at the 1-month follow-up compared with the CON condition. The SM condition had higher program attendance rates (P = 0.03), and a greater proportion of participants reregistered for additional exercise programs (P = 0.048) compared with the CON condition. Participants in both conditions experienced improvements in health-related quality of life, waist circumference, and fitness (P values <0.05). These findings provide promising initial support for the use of a real-time CGM to foster self-monitoring and exercise behavior in individuals living with prediabetes or T2D.

  14. Metabolic regulation during constant moderate physical exertion in extreme conditions in Type 1 diabetes.

    PubMed

    Valletta, J J; Chipperfield, A J; Clough, G F; Byrne, C D

    2012-06-01

    Constant moderate intensity physical exertion in humid environments at altitude poses a considerable challenge to maintaining euglycaemia with Type 1 diabetes. Blood glucose concentrations and energy expenditure were continuously recorded in a person trekking at altitude in a tropical climate to quantify changes in glucose concentrations in relation to energy expenditure. Blood glucose concentrations and energy expenditure were continuously monitored with a Guardian® real-time continuous glucose monitoring system (CGMS) and a SenseWear® Pro3 armband (BodyMedia Inc., USA), in a 27-year-old woman with Type 1 diabetes, during her climb up Mount Kinabalu in Borneo (c. 4095 m). Comparative control data from the same person was collected in the UK (temperate climate at sea level) and Singapore (tropical climate at sea level). Maximum physical effort during the climb was < 60% VO(2MAX) (maximal oxygen consumption). Mean daily calorific intakes were 2300 kcal (UK), 2370 kcal (Singapore) and 2274 kcal (Mount Kinabalu), and mean daily insulin doses were 54 U (UK), 40 U (Singapore) and 47 U (Mount Kinabalu). Despite markedly increased energy expenditure during the climb [4202 kcal (Mount Kinabalu) vs. 2948 kcal (UK) and 2662 kcal (Singapore)], mean blood glucose was considerably higher during the trek up Mount Kinabalu [13.2 ± 5.9 mmol/l, vs. 7.9 ± 3.8 mmol/l (UK) and 8.6 ± 4.0 mmol/l (Singapore)]. Marked unexpected hyperglycaemia occurred while trekking on Mount Kinabalu, despite similar calorie consumption and insulin doses to control conditions. Because of the risk of unexpected hyperglycaemia in these conditions, we recommend that patients embarking on similar activity holidays undertake frequent blood glucose monitoring. © 2011 The Authors. Diabetic Medicine © 2011 Diabetes UK.

  15. Optimal insulin pump dosing and postprandial glycemia following a pizza meal using the continuous glucose monitoring system.

    PubMed

    Jones, Susan M; Quarry, Jill L; Caldwell-McMillan, Molly; Mauger, David T; Gabbay, Robert A

    2005-04-01

    We attempted to identify an optimal insulin pump meal bolus by comparing postprandial sensor glucose values following three methods of insulin pump meal bolusing for a consistent pizza meal. Twenty-four patients with type 1 diabetes participated in a study to compare postprandial glucose values following three meal bolus regimens for a consistent evening pizza meal. Each participant utilized the following insulin lispro regimens on consecutive evenings, and glucose values were tracked by the Continuous Glucose Monitoring System (CGMS, Medtronic MiniMed, Northridge, CA): (a) single-wave bolus (100% of insulin given immediately); (b) 4-h dual-wave bolus (50% of insulin given immediately and 50% given over a 4-h period); and (c) 8-h dual-wave bolus (50% of insulin given immediately and 50% given over a 8-h period). Total insulin bolus amount was kept constant for each pizza meal. Divergence in blood glucose among the regimens was greatest at 8-12 h. The 8-h dual-wave bolus provided the best glycemic control and lowest mean glucose values (singlewave bolus, 133 mg/dL; 4-h dual-wave bolus, 145 mg/dL; 8-h dual-wave bolus, 104 mg/dL), leading to a difference in mean glucose of 29 mg/dL for the single-wave bolus versus the 8-h dual-wave bolus and 42 mg/dL for the 4-h dual-wave bolus versus the 8-h dual-wave bolus. The lower mean glucose in the 8-h dual-wave bolus was not associated with any increased incidence of hypoglycemia. Use of a dual-wave bolus extended over an 8-h period following a pizza meal provided significantly less postprandial hyperglycemia in the late postprandial period (8-12 h) with no increased risk of hypoglycemia.

  16. Drought Dynamics and Food Security in Ukraine

    NASA Astrophysics Data System (ADS)

    Kussul, N. M.; Kogan, F.; Adamenko, T. I.; Skakun, S. V.; Kravchenko, O. M.; Kryvobok, O. A.; Shelestov, A. Y.; Kolotii, A. V.; Kussul, O. M.; Lavrenyuk, A. M.

    2012-12-01

    In recent years food security became a problem of great importance at global, national and regional scale. Ukraine is one of the most developed agriculture countries and one of the biggest crop producers in the world. According to the 2011 statistics provided by the USDA FAS, Ukraine was the 8th largest exporter and 10th largest producer of wheat in the world. Therefore, identifying current and projecting future trends in climate and agriculture parameters is a key element in providing support to policy makers in food security. This paper combines remote sensing, meteorological, and modeling data to investigate dynamics of extreme events, such as droughts, and its impact on agriculture production in Ukraine. Two main problems have been considered in the study: investigation of drought dynamics in Ukraine and its impact on crop production; and investigation of crop growth models for yield and production forecasting and its comparison with empirical models that use as a predictor satellite-derived parameters and meteorological observations. Large-scale weather disasters in Ukraine such as drought were assessed using vegetation health index (VHI) derived from satellite data. The method is based on estimation of green canopy stress/no stress from indices, characterizing moisture and thermal conditions of vegetation canopy. These conditions are derived from the reflectance/emission in the red, near infrared and infrared parts of solar spectrum measured by the AVHRR flown on the NOAA afternoon polar-orbiting satellites since 1981. Droughts were categorized into exceptional, extreme, severe and moderate. Drought area (DA, in % from total Ukrainian area) was calculated for each category. It was found that maximum DA over past 20 years was 10% for exceptional droughts, 20% for extreme droughts, 50% for severe droughts, and 80% for moderate droughts. Also, it was shown that in general the drought intensity and area did not increase considerably over past 10 years. Analysis of interrelation between DA of different categories at oblast level with agriculture production will be discussed as well. A comparative study was carried out to assess three approaches to forecast winter wheat yield in Ukraine at oblast level: (i) empirical regression-based model that uses as a predictor 16-day NDVI composites derived from MODIS at the 250 m resolution, (ii) empirical regression-based model that uses as predictors meteorological parameters, and (iii) adapted for Ukraine Crop Growth Monitoring System (CGMS) that is based on WOFOST crop growth simulation model and meteorological parameters. These three approaches were calibrated for 2000-2009 and 2000-2010 data, and compared while performing forecasts on independent data for 2010 and 2011. For 2010, the best results in terms of root mean square error (RMSE, by oblast, deviation of predicted values from official statistics) were achieved using CGMS models: 0.3 t/ha. For NDVI and meteorological models RMSE values were 0.79 and 0.77 t/ha, respectively. When forecasting winter wheat yield for 2011, the following RMSE values were obtained: 0.58 t/ha for CGMS, 0.56 t/ha for meteorological model, and 0.62 t/ha for NDVI. In this case performance of all three approaches was relatively the same. Acknowledgements. This work was supported by the U.S. CRDF Grant "Analysis of climate change & food security based on remote sensing & in situ data sets" (UKB2-2972-KV-09).

  17. Molecular mechanisms of OLIG2 transcription factor in brain cancer

    PubMed Central

    Lian, Nathan; Kesari, Santosh

    2016-01-01

    Oligodendrocyte lineage transcription factor 2 (OLIG2) plays a pivotal role in glioma development. Here we conducted a comprehensive study of the critical gene regulatory networks involving OLIG2. These include the networks responsible for OLIG2 expression, its translocation to nucleus, cell cycle, epigenetic regulation, and Rho-pathway interactions. We described positive feedback loops including OLIG2: loops of epigenetic regulation and loops involving receptor tyrosine kinases. These loops may be responsible for the prolonged oncogenic activity of OLIG2. The proposed schemes for epigenetic regulation of the gene networks involving OLIG2 are confirmed by patient survival (Kaplan–Meier) curves based on the cancer genome atlas (TCGA) datasets. Finally, we elucidate the Coherent-Gene Modules (CGMs) networks—framework of OLIG2 involvement in cancer. We showed that genes interacting with OLIG2 formed eight CGMs having a set of intermodular connections. We showed also that among the genes involved in these modules the most connected hub is EGFR, then, on lower level, HSP90 and CALM1, followed by three lower levels including epigenetic genes KDM1A and NCOR1. The genes on the six upper levels of the hierarchy are involved in interconnections of all eight CGMs and organize functionally defined gene-signaling subnetworks having specific functions. For example, CGM1 is involved in epigenetic control. CGM2 is significantly related to cell proliferation and differentiation. CGM3 includes a number of interconnected helix–loop–helix transcription factors (bHLH) including OLIG2. Many of these TFs are partially controlled by OLIG2. The CGM4 is involved in PDGF-related: angiogenesis, tumor cell proliferation and differentiation. These analyses provide testable hypotheses and approaches to inhibit OLIG2 pathway and relevant feed-forward and feedback loops to be interrogated. This broad approach can be applied to other TFs. PMID:27447975

  18. Continuous glucose monitoring technology for personal use: an educational program that educates and supports the patient.

    PubMed

    Evert, Alison; Trence, Dace; Catton, Sarah; Huynh, Peter

    2009-01-01

    The purpose of this article is to describe the development and implementation of an educational program for the initiation of real-time continuous glucose monitoring (CGM) technology for personal use, not 3-day CGMS diagnostic studies. The education program was designed to meet the needs of patients managing their diabetes with either diabetes medications or insulin pump therapy in an outpatient diabetes education center using a team-based approach. Observational research, complemented by literature review, was used to develop an educational program model and teaching strategies. Diabetes educators, endocrinologists, CGM manufacturer clinical specialists, and patients with diabetes were also interviewed for their clinical observations and experience. The program follows a progressive educational model. First, patients learn in-depth about real-time CGM technology by attending a group presensor class that provides detailed information about CGM. This presensor class facilitates self-selection among patients concerning their readiness to use real-time CGM. If the patient decides to proceed with real-time CGM use, CGM initiation is scheduled, using a clinic-centered protocol for both start-up and follow-up. Successful use of real-time CGM involves more than just patient enthusiasm or interest in a new technology. Channeling patient interest into a structured educational setting that includes the benefits and limitations of real-time CGM helps to manage patient expectations.

  19. Glycaemic index of selected foodstuffs in healthy persons.

    PubMed

    Fajkusova, Zuzana; Jadviscokova, Tereza; Pallayova, Maria; Matuskova, Veronika; Luza, Jiri; Kuzmina, Galina

    2007-12-01

    The aim of this study was to determine glycaemic index (GI) of 10 popular foodstuffs/mixed meals in healthy persons. Ten tested foodstuffs and glucose standard were consumed in three replicates in the course of a defined 9-day meal plan: puffed rice squares with chocolate, dark chocolate, white bread, honey and glucose for breakfast (at 7 a.m.) and dinner (at 8 p.m.); pasta with meat, fried fish with mashed potatoes, and buttered apricot dumplings for lunch (at 12 a.m.); wafers, puffed spelt squares with chocolate, and tomato soup for snack (at 4 p.m.). Each portion contained 50 g of carbohydrates and was consumed within 30 minutes. Glucose concentrations were measured by means of the Continous Glucose Monitoring System (CGMS, Medtronic Minimed, Northridge, CA, USA). The results were processed by Solutions Software (Medtronic Minimed, Northridge, CA, USA) and DegifXL4 software, Palacký University, Olomouc, CZ. Twenty healthy persons aged 21.9 +/- 1.39 y (mean +/- SE), BMI 23.6 +/- 0.63 kg/m(2) completed the study. GI of tested foodstuffs ranged from 34.7 % (chocolate) to 105.3 % (puffed rice squares with chocolate). There were more than tenfold differences between minimal and maximal values of the GI for some foodstuffs. Significant interindividual differences were found between GIs of foodstuffs. In twenty healthy persons the glycaemic indexes of ten popular foodstuffs were determined, to be added to the nutritional labels in order to facilitate the optimum meal planning.

  20. Susceptibility of interstitial continuous glucose monitor performance to sleeping position.

    PubMed

    Mensh, Brett D; Wisniewski, Natalie A; Neil, Brian M; Burnett, Daniel R

    2013-07-01

    Developing a round-the-clock artificial pancreas requires accurate and stable continuous glucose monitoring. The most widely used continuous glucose monitors (CGMs) are percutaneous, with the sensor residing in the interstitial space. Inaccuracies in percutaneous CGM readings during periods of lying on the devices (e.g., in various sleeping positions) have been anecdotally reported but not systematically studied. In order to assess the impact of sleep and sleep position on CGM performance, we conducted a study in human subjects in which we measured the variability of interstitial CGM data at night as a function of sleeping position. Commercially available sensors were placed for 4 days in the abdominal subcutaneous tissue in healthy, nondiabetic volunteers (four sensors per person, two per side). Nocturnal sleeping position was determined from video recordings and correlated to sensor data. We observed that, although the median of the four sensor readings was typically 70-110 mg/dl during sleep, individual sensors intermittently exhibited aberrant glucose readings (>25 mg/dl away from median) and that these aberrant readings were strongly correlated with subjects lying on the sensors. We expected and observed that most of these aberrant sleep-position-related CGM readings were sudden decreases in reported glucose values, presumably due to local blood-flow decreases caused by tissue compression. Curiously, in rare cases, the aberrant CGM readings were elevated values. These findings highlight limitations in our understanding of interstitial fluid physiology in the subcutaneous space and have significant implications for the utilization of sensors in the construction of an artificial pancreas. © 2013 Diabetes Technology Society.

  1. Probing Circum Galactic Medium of Galaxies in Emission

    NASA Astrophysics Data System (ADS)

    Gupta, Anjali

    Nearby late-type galaxies are missing a large fraction of their baryonic mass. Galaxies have also lost most of the metals that they produced. Cosmological simulations of galaxy formation suggest that a large fraction of the missing baryonic mass and metals should reside in the circum-galactic medium (CGM), in a warm-hot gas phase at temperatures between one million and 10 million K. Although theoretical models predict the existence of the warm-hot gas in the CGM, detecting and characterizing the diffuse CGM has been difficult. At the expected temperatures the baryons are in the form of highly ionized plasma,observable in soft X-rays. Using observations from Chandra, XMM-Newton and Suzaku, we found that there is a huge reservoir of ionized gas around the Milky Way, with a mass of over 2 billion solar masses and a radius of over 100 kpc. The baryonic mass fraction of this gas is consistent with the Universal value. Similar to the Milky Way, other spiral galaxies should also have massive, extended reservoirs of ionized hot gas in the CGM. Searches of such a warm-hot gas in CGMs of external galaxies, however, have given mixed results. There are three sets of observations which are in apparent conflict: (1) CGMs around nearby spiral galaxies are apparently not extended (this might be an observational bias which we will test with the proposed program); (2) CGMs around massive spirals are extended and massive, but given the large mass of these galaxies, about an order of magnitude higher than the Milky Way, the fraction of baryons in the CGM is still small, and the baryons are still missing; (3) the Milky Way CGM is extended and massive and may account for the missing baryons. Theoretical models suggest that CGM properties depend on galaxy properties such as the gravitational mass, stellar mass and specific star formation rate. So to understand the physics of galaxy formation and evolution and the role of the accretion and feedback mechanisms, we must probe the entire parameter space of these galaxy properties. Given that CGMs of giant massive galaxies have been studied already, in this proposed program we will study galaxies with lower, Milky Way-type masses and a range of star formation rate. Our proposed program has two parts: (1) new observations with Suzaku (now archived), and (2) archival XMM-Newton observations (1.09 Ms). We have been awarded 200ks of Suzaku time to detect and characterize the warm-hot CGM in a nearby late type galaxy NGC3221 with very high sSFR. We request support for the analysis of these observations. With our novel XMM-Newton program we will probe the relevant parameter space of stellar mass, star formation rate and gravitational mass of galaxies. XMM-Newton has the ideal combination of large field of view and large effective area at soft X-ray energies, which is crucial for faint diffuse emission studies. With the proposed program we will detect and characterize the warm-hot CGM in our targets, determine their density profiles, and measure their mass and baryon fraction. We will probe an extended parameter space of galaxy properties to understand how the properties of CGMs depend on stellar mass, halo mass, and star formation rate of galaxies. With the proposed study we will present the best and the most comprehensive phenomenological picture of the CGM of external galaxies which we will compare with theoretical models of galaxy formation. This will significantly advance our understanding of galaxy formation and evolution, feedback and metal enrichment. The proposed study is relevant to the NASA Strategic Goal to discover how the Universe works, explore how the Universe began and evolved into its present form. The PI's efforts to involve undergraduates from a Community College in her research will improve retention of students in STEM disciplines by providing opportunities and activities along the full length of the education pipeline (NASA Strategic Plan sub-goal Goal 6).

  2. Glucose sensing in the peritoneal space offers faster kinetics than sensing in the subcutaneous space.

    PubMed

    Burnett, Daniel R; Huyett, Lauren M; Zisser, Howard C; Doyle, Francis J; Mensh, Brett D

    2014-07-01

    The paramount goal in the treatment of type 1 diabetes is the maintenance of normoglycemia. Continuous glucose monitoring (CGM) technologies enable frequent sensing of glucose to inform exogenous insulin delivery timing and dosages. The most commonly available CGMs are limited by the physiology of the subcutaneous space in which they reside. The very same advantages of this minimally invasive approach are disadvantages with respect to speed. Because subcutaneous blood flow is sensitive to local fluctuations (e.g., temperature, mechanical pressure), subcutaneous sensing can be slow and variable. We propose the use of a more central, physiologically stable body space for CGM: the intraperitoneal space. We compared the temporal response characteristics of simultaneously placed subcutaneous and intraperitoneal sensors during intravenous glucose tolerance tests in eight swine. Using compartmental modeling based on simultaneous intravenous sensing, blood draws, and intraarterial sensing, we found that intraperitoneal kinetics were more than twice as fast as subcutaneous kinetics (mean time constant of 5.6 min for intraperitoneal vs. 12.4 min for subcutaneous). Combined with the known faster kinetics of intraperitoneal insulin delivery over subcutaneous delivery, our findings suggest that artificial pancreas technologies may be optimized by sensing glucose and delivering insulin in the intraperitoneal space. © 2014 by the American Diabetes Association.

  3. Glucose Sensing in the Peritoneal Space Offers Faster Kinetics Than Sensing in the Subcutaneous Space

    PubMed Central

    Burnett, Daniel R.; Huyett, Lauren M.; Zisser, Howard C.; Doyle, Francis J.

    2014-01-01

    The paramount goal in the treatment of type 1 diabetes is the maintenance of normoglycemia. Continuous glucose monitoring (CGM) technologies enable frequent sensing of glucose to inform exogenous insulin delivery timing and dosages. The most commonly available CGMs are limited by the physiology of the subcutaneous space in which they reside. The very same advantages of this minimally invasive approach are disadvantages with respect to speed. Because subcutaneous blood flow is sensitive to local fluctuations (e.g., temperature, mechanical pressure), subcutaneous sensing can be slow and variable. We propose the use of a more central, physiologically stable body space for CGM: the intraperitoneal space. We compared the temporal response characteristics of simultaneously placed subcutaneous and intraperitoneal sensors during intravenous glucose tolerance tests in eight swine. Using compartmental modeling based on simultaneous intravenous sensing, blood draws, and intraarterial sensing, we found that intraperitoneal kinetics were more than twice as fast as subcutaneous kinetics (mean time constant of 5.6 min for intraperitoneal vs. 12.4 min for subcutaneous). Combined with the known faster kinetics of intraperitoneal insulin delivery over subcutaneous delivery, our findings suggest that artificial pancreas technologies may be optimized by sensing glucose and delivering insulin in the intraperitoneal space. PMID:24622798

  4. Different methods and settings for glucose monitoring for gestational diabetes during pregnancy.

    PubMed

    Raman, Puvaneswary; Shepherd, Emily; Dowswell, Therese; Middleton, Philippa; Crowther, Caroline A

    2017-10-29

    Incidence of gestational diabetes mellitus (GDM) is increasing worldwide. Blood glucose monitoring plays a crucial part in maintaining glycaemic control in women with GDM and is generally recommended by healthcare professionals. There are several different methods for monitoring blood glucose which can be carried out in different settings (e.g. at home versus in hospital). The objective of this review is to compare the effects of different methods and settings for glucose monitoring for women with GDM on maternal and fetal, neonatal, child and adult outcomes, and use and costs of health care. We searched the Cochrane Pregnancy and Childbirth Group Trials Register (30 September 2016) and reference lists of retrieved studies. Randomised controlled trials (RCTs) or quasi-randomised controlled trials (qRCTs) comparing different methods (such as timings and frequencies) or settings, or both, for blood glucose monitoring for women with GDM. Two authors independently assessed study eligibility, risk of bias, and extracted data. Data were checked for accuracy.We assessed the quality of the evidence for the main comparisons using GRADE, for:- primary outcomes for mothers: that is, hypertensive disorders of pregnancy; caesarean section; type 2 diabetes; and- primary outcomes for children: that is, large-for-gestational age; perinatal mortality; death or serious morbidity composite; childhood/adulthood neurosensory disability;- secondary outcomes for mothers: that is, induction of labour; perineal trauma; postnatal depression; postnatal weight retention or return to pre-pregnancy weight; and- secondary outcomes for children: that is, neonatal hypoglycaemia; childhood/adulthood adiposity; childhood/adulthood type 2 diabetes. We included 11 RCTs (10 RCTs; one qRCT) that randomised 1272 women with GDM in upper-middle or high-income countries; we considered these to be at a moderate to high risk of bias. We assessed the RCTs under five comparisons. For outcomes assessed using GRADE, we downgraded for study design limitations, imprecision and inconsistency. Three trials received some support from commercial partners who provided glucose meters or financial support, or both. Main comparisons Telemedicine versus standard care for glucose monitoring (five RCTs): we observed no clear differences between the telemedicine and standard care groups for the mother, for:- pre-eclampsia or pregnancy-induced hypertension (risk ratio (RR) 1.49, 95% confidence interval (CI) 0.69 to 3.20; 275 participants; four RCTs; very low quality evidence);- caesarean section (average RR 1.05, 95% CI 0.72 to 1.53; 478 participants; 5 RCTs; very low quality evidence); and- induction of labour (RR 1.06, 95% CI 0.63 to 1.77; 47 participants; 1 RCT; very low quality evidence);or for the child, for:- large-for-gestational age (RR 1.41, 95% CI 0.76 to 2.64; 228 participants; 3 RCTs; very low quality evidence);- death or serious morbidity composite (RR 1.06, 95% CI 0.68 to 1.66; 57 participants; 1 RCT; very low quality evidence); and- neonatal hypoglycaemia (RR 1.14, 95% CI 0.48 to 2.72; 198 participants; 3 RCTs; very low quality evidence).There were no perinatal deaths in two RCTs (131 participants; very low quality evidence). Self-monitoring versus periodic glucose monitoring (two RCTs): we observed no clear differences between the self-monitoring and periodic glucose monitoring groups for the mother, for:- pre-eclampsia (RR 0.17, 95% CI 0.01 to 3.49; 58 participants; 1 RCT; very low quality evidence); and- caesarean section (average RR 1.18, 95% CI 0.61 to 2.27; 400 participants; 2 RCTs; low quality evidence);or for the child, for:- perinatal mortality (RR 1.54, 95% CI 0.21 to 11.24; 400 participants; 2 RCTs; very low quality evidence);- large-for-gestational age (RR 0.82, 95% CI 0.50 to 1.37; 400 participants; 2 RCTs; low quality evidence); and- neonatal hypoglycaemia (RR 0.64, 95% CI 0.39 to 1.06; 391 participants; 2 RCTs; low quality evidence). Continuous glucose monitoring system (CGMS) versus self-monitoring of glucose (two RCTs): we observed no clear differences between the CGMS and self-monitoring groups for the mother, for:- caesarean section (RR 0.91, 95% CI 0.68 to 1.20; 179 participants; 2 RCTs; very low quality evidence);or for the child, for:- large-for-gestational age (RR 0.67, 95% CI 0.43 to 1.05; 106 participants; 1 RCT; very low quality evidence) and- neonatal hypoglycaemia (RR 0.79, 95% CI 0.35 to 1.78; 179 participants; 2 RCTs; very low quality evidence).There were no perinatal deaths in the two RCTs (179 participants; very low quality evidence). Other comparisons Modem versus telephone transmission for glucose monitoring (one RCT): none of the review's primary outcomes were reported in this trial Postprandial versus preprandial glucose monitoring (one RCT): we observed no clear differences between the postprandial and preprandial glucose monitoring groups for the mother, for:- pre-eclampsia (RR 1.00, 95% CI 0.15 to 6.68; 66 participants; 1 RCT);- caesarean section (RR 0.62, 95% CI 0.29 to 1.29; 66 participants; 1 RCT); and- perineal trauma (RR 0.38, 95% CI 0.11 to 1.29; 66 participants; 1 RCT);or for the child, for:- neonatal hypoglycaemia (RR 0.14, 95% CI 0.02 to 1.10; 66 participants; 1 RCT).There were fewer large-for-gestational-age infants born to mothers in the postprandial compared with the preprandial glucose monitoring group (RR 0.29, 95% CI 0.11 to 0.78; 66 participants; 1 RCT). Evidence from 11 RCTs assessing different methods or settings for glucose monitoring for GDM suggests no clear differences for the primary outcomes or other secondary outcomes assessed in this review.However, current evidence is limited by the small number of RCTs for the comparisons assessed, small sample sizes, and the variable methodological quality of the RCTs. More evidence is needed to assess the effects of different methods and settings for glucose monitoring for GDM on outcomes for mothers and their children, including use and costs of health care. Future RCTs may consider collecting and reporting on the standard outcomes suggested in this review.

  5. Quantifying temporal glucose variability in diabetes via continuous glucose monitoring: mathematical methods and clinical application.

    PubMed

    Kovatchev, Boris P; Clarke, William L; Breton, Marc; Brayman, Kenneth; McCall, Anthony

    2005-12-01

    Continuous glucose monitors (CGMs) collect detailed blood glucose (BG) time series, which carry significant information about the dynamics of BG fluctuations. In contrast, the methods for analysis of CGM data remain those developed for infrequent BG self-monitoring. As a result, important information about the temporal structure of the data is lost during the translation of raw sensor readings into clinically interpretable statistics and images. The following mathematical methods are introduced into the field of CGM data interpretation: (1) analysis of BG rate of change; (2) risk analysis using previously reported Low/High BG Indices and Poincare (lag) plot of risk associated with temporal BG variability; and (3) spatial aggregation of the process of BG fluctuations and its Markov chain visualization. The clinical application of these methods is illustrated by analysis of data of a patient with Type 1 diabetes mellitus who underwent islet transplantation and with data from clinical trials. Normative data [12,025 reference (YSI device, Yellow Springs Instruments, Yellow Springs, OH) BG determinations] in patients with Type 1 diabetes mellitus who underwent insulin and glucose challenges suggest that the 90%, 95%, and 99% confidence intervals of BG rate of change that could be maximally sustained over 15-30 min are [-2,2], [-3,3], and [-4,4] mg/dL/min, respectively. BG dynamics and risk parameters clearly differentiated the stages of transplantation and the effects of medication. Aspects of treatment were clearly visualized by graphs of BG rate of change and Low/High BG Indices, by a Poincare plot of risk for rapid BG fluctuations, and by a plot of the aggregated Markov process. Advanced analysis and visualization of CGM data allow for evaluation of dynamical characteristics of diabetes and reveal clinical information that is inaccessible via standard statistics, which do not take into account the temporal structure of the data. The use of such methods improves the assessment of patients' glycemic control.

  6. Accuracy of continuous glucose monitoring during exercise in type 1 diabetes pregnancy.

    PubMed

    Kumareswaran, Kavita; Elleri, Daniela; Allen, Janet M; Caldwell, Karen; Nodale, Marianna; Wilinska, Malgorzata E; Amiel, Stephanie A; Hovorka, Roman; Murphy, Helen R

    2013-03-01

    Performance of continuous glucose monitors (CGMs) may be lower when glucose levels are changing rapidly, such as occurs during physical activity. Our aim was to evaluate accuracy of a current-generation CGM during moderate-intensity exercise in type 1 diabetes (T1D) pregnancy. As part of a study of 24-h closed-loop insulin delivery in 12 women with T1D (disease duration, 17.6 years; glycosylated hemoglobin, 6.4%) during pregnancy (gestation, 21 weeks), we evaluated the Freestyle Navigator(®) sensor (Abbott Diabetes Care, Alameda, CA) during afternoon (15:00-18:00 h) and morning (09:30-12:30 h) exercise (55 min of brisk walking on a treadmill followed by a 2-h recovery), compared with sedentary conditions (18:00-09:00 h). Plasma (reference) glucose, measured at regular 15-30-min intervals with the YSI Ltd. (Fleet, United Kingdom) model YSI 2300 analyzer, was used to assess CGM performance. Sensor accuracy, as indicated by the larger relative absolute difference (RAD) between paired sensor and reference glucose values, was lower during exercise compared with rest (median RAD, 11.8% vs. 18.4%; P<0.001). These differences remained significant when correcting for plasma glucose relative rate of change (P<0.001). Analysis by glucose range showed lower accuracy during hypoglycemia for both sedentary (median RAD, 24.4%) and exercise (median RAD, 32.1%) conditions. Using Clarke error grid analysis, 96% of CGM values were clinically safe under resting conditions compared with only 87% during exercise. Compared with sedentary conditions, accuracy of the Freestyle Navigator CGM was lower during moderate-intensity exercise in pregnant women with T1D. This difference was particularly marked in hypoglycemia and could not be solely explained by the glucose rate of change associated with physical activity.

  7. Continuous glucose monitors: use of waveform versus glycemic values in the improvements of glucose control, quality of life, and fear of hypoglycemia.

    PubMed

    Walker, Tomas C; Yucha, Carolyn B

    2014-05-01

    How patients are benefitting from continuous glucose monitoring (CGM) remains poorly understood. The focus on numerical glucose values persists, even though access to the glucose waveform and rate of change may contribute more to improved control. This pilot study compared outcomes of patients using CGMs with or without access to the numerical values on their CGM. Ten persons with type 1 diabetes, naïve to CGM use, enrolled in a 12-week study. Subjects were randomly assigned to either unmodified CGM receivers, or to CGM receivers that had their numerical values obscured but otherwise functioned normally. HbA1c, quality of life (QLI-D), and fear of hypoglycemia (HFS) were assessed, at baseline and at week 12. Baseline HbA1c for the entire group was 7.46 ± 1.27%. At week 12 the experimental group HbA1c reduction was 1.5 ± 0.9% (p < .05), the control group's reduction was 0.06 ± 0.61% (p > .05). Repeated measures testing revealed no significant difference in HbA1c reduction between groups. Both groups had reductions in HFS; these reductions were statistically significant within groups (p < .05), but not between groups. QLI-D indices demonstrated improvements (p < .05) in QLI-D total and the health and family subscales, but not between groups. The results of this pilot study suggest that benefits of CGM extend beyond reductions in HbA1c to reductions in fear of hypoglycemia and improvements in quality of life. The display of a numerical glucose value did not improve control when compared to numerically blinded units. © 2014 Diabetes Technology Society.

  8. Diabetes induction by total pancreatectomy in minipigs with simultaneous splenectomy: a feasible approach for advanced diabetes research.

    PubMed

    Heinke, Sophie; Ludwig, Barbara; Schubert, Undine; Schmid, Janine; Kiss, Thomas; Steffen, Anja; Bornstein, Stefan; Ludwig, Stefan

    2016-09-01

    Safe and reliable diabetes models are a key prerequisite for advanced preclinical studies on diabetes. Chemical induction is the standard model of diabetes in rodents and also widely used in large animal models of non-human primates and minipigs. However, uncertain efficacy, the potential of beta-cell regeneration, and relevant side effects are debatable aspects particularly in large animals. Therefore, we aimed to evaluate a surgical approach of total pancreatectomy combined with splenectomy for diabetes induction in an exploratory study in Goettingen minipigs. Total pancreatectomy was performed in Goettingen minipigs (n = 4) under general anesthesia and endotracheal intubation. Prior to surgery, a central venous line was established for drug application and blood sampling. After median laparotomy, splenectomy was performed and the lobular pancreas was carefully dissected with particular attention to the duodenal vascular arcade. Close monitoring of blood glucose was initiated immediately after surgery by standard glucometer measurement or continuous glucose monitoring systems (CGMS). Exogenous insulin was given by multiple daily subcutaneous (s.c.) injections or via insulin pump systems (CSII). Complete endogenous insulin deficiency was confirmed by intravenous glucose tolerance test (ivGTT) and measurement of c-peptide. For establishing a suitable regimen for diabetes management, the animals were followed for 4-6 weeks. Following pancreatectomy and splenectomy, the animals showed a quick recovery from surgery and initial analgetic medication and volume substitution could be terminated within 24 h. A rapid increase in blood glucose was observed immediately following pancreatectomy necessitating insulin therapy. The induced exocrine insufficiency did not cause any clinical symptoms. Complete insulin deficiency could be confirmed in all animals by determination of negative c-peptide during glucose challenge. The two regimen of insulin treatment (multiple daily injections (MDI) and continuous subcutaneous insulin infusion (CSII)) were both feasible with respect to acceptable glycemic control whereas CSII was considerably advantageous in comfort and popularity for both animals and care takers. Surgical pancreatectomy in combination with splenectomy to facilitate access to the pancreas is a feasible model for efficient diabetes induction in minipigs. The procedure itself and postoperative animal care could be performed without complications in this exploratory study. Nevertheless, this approach requires well-equipped infrastructure, experienced and skilled surgeons and anesthesiologists and dedicated animal care takers. The impact of total pancreatectomy in combination with splenectomy on the digestive and immune system must be considered in the design and definition of end points of experimental diabetes and transplantation studies. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Effective stabilization of CLA by microencapsulation in pea protein.

    PubMed

    Costa, A M M; Nunes, J C; Lima, B N B; Pedrosa, C; Calado, V; Torres, A G; Pierucci, A P T R

    2015-02-01

    CLA was microencapsulated by spray drying in ten varied wall systems (WS) consisting of pea protein isolate or pea protein concentrate (PPC) alone at varied core:WS ratios (1:2; 1:3 and 1:4), or blended with maltodextrin (M) and carboxymethylcellulose at a pea protein:carbohydrate ratio of 3:1. The physical-chemical properties of the CLA microparticles were characterised by core retention, microencapsulation efficiency (ME), particle size and moisture. CLA:M:PPC (1:1:3) showed the most promising results, thus we evaluated the effect of M addition in the WS on other physical-chemical characteristics and oxidative stability (CLA isomer profile, quantification of CLA and volatile compounds by SPME coupled with CG-MS) during two months of storage at room temperature, CLA:PPC (1:4) was selected for comparisons. CLA:M:PPC (1:1:3) microparticles demonstrated better morphology, solubility, dispersibility and higher glass-transition temperature values. M addition did not influence the oxidative stability of CLA, however its presence improved physical-chemical characteristics necessary for food applications. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Nocturnal continuous glucose monitoring: accuracy and reliability of hypoglycemia detection in patients with type 1 diabetes at high risk of severe hypoglycemia.

    PubMed

    Bay, Christiane; Kristensen, Peter Lommer; Pedersen-Bjergaard, Ulrik; Tarnow, Lise; Thorsteinsson, Birger

    2013-05-01

    A reliable method to detect biochemical nocturnal hypoglycemia is highly needed, especially in patients with recurrent severe hypoglycemia. We evaluated reliability of nocturnal continuous glucose monitoring (CGM) in patients with type 1 diabetes at high risk of severe hypoglycemia. Seventy-two type 1 diabetes patients with recurrent severe hypoglycemia (two or more events within the last year) participated for 4 nights in blinded CGM recordings (Guardian(®) REAL-Time CGMS and Sof-Sensor(®); Medtronic MiniMed, Northridge, CA). Blood was drawn hourly from 23:00 to 07:00 h for plasma glucose (PG) measurements (gold standard). Valid data were obtained in 217 nights. The sensitivity of CGM was 65% (95% confidence interval, 53-77%) below 4 mmol/L, 40% (24-56%) below 3 mmol/L, and 17% (0-47%) below 2.2 mmol/L. PG and CGM readings correlated in the total measurement range (Spearman's ρ=0.82; P<0.001). In the normo- and hyperglycemic ranges CGM underestimated PG by 1.1 mmol/L (0.9-1.2 mmol/L) (P<0.001); in contrast, in the hypoglycemic range (PG<4 mmol/L) CGM overestimated PG levels by 1.0 mmol/L (P<0.001). The mean absolute relative differences in the hypo- (≤3.9 mmol/L), normo- (4-9.9 mmol/L), and hyperglycemic (≥10 mmol/L) ranges were 45% (37-53%), 23% (22-25%), and 20% (19-21%), respectively. Continuous glucose error grid analysis indicated a clinical accuracy of 56%, 99%, and 93% in the hypo-, normo-, and hyperglycemic ranges, respectively. The accuracy in the hypoglycemic range of nocturnal CGM data using Sof-Sensor is suboptimal in type 1 diabetes patients at high risk of severe hypoglycemia. To ensure clinical useful sensitivity in detection of nocturnal hypoglycemic episodes, an alarm threshold should not be lower than 4 mmol/L.

  11. Disappearance of six pesticides in fresh and processed zucchini, bioavailability and health risk assessment.

    PubMed

    Oliva, J; Cermeño, S; Cámara, M A; Martínez, G; Barba, A

    2017-08-15

    A field study was carried out on the dissipation of three insecticides and three fungicides during the freezing of zucchini. A simultaneous residue analysis method is validated using QuEChERS extraction with acetonitrile and CG-MS and LC-MS analysis. The residues detected after field application never exceeded the established maximum residue limits. The processing factors calculated (fresh product/frozen product) are lower than 1, indicating a clear influence of the stages of the freezing process, especially the washing and blanching. The in vitro study of bioavailability establishes a low percentage of stomach absorption capacity. The level of residues detected in fresh zucchini and the Estimated Daily Intake calculated for Spain suggest that there is no risk of acute toxicity due to dietary exposure. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Prognostic value of early in-hospital glycemic excursion in elderly patients with acute myocardial infarction.

    PubMed

    Su, Gong; Mi, Shu-hua; Li, Zhao; Tao, Hong; Yang, Hong-xia; Zheng, Hong

    2013-02-11

    Acute phase hyperglycemia has been associated with increased mortality in patients with acute myocardial infarction (AMI). However, the predictive value of glycemic excursion for adverse outcome in elderly AMI patients is not clear. The aim of this study is to investigate the prognostic value of early in-hospital glycemic excursion and hemoglobin A1c (HbA1c) for one-year major adverse cardiac event (MACE) in elderly patients with AMI. We studied 186 elderly AMI patients, whose clinical data were collected and the Global Registry of Acute Coronary Events (GRACE) risk score were calculated on admission. The fluctuations of blood glucose in patients were measured by a continuous glucose monitoring system (CGMS) for 72 hours. Participants were grouped into tertiles of mean amplitude of glycemic excursions (MAGE) and grouped into HbA1c levels (as ≥6.5% or <6.5%). The MACE of patients, including new-onset myocardial infarction, acute heart failure and cardiac death, was documented during one year follow-up. The relationship of MAGE and HbA1c to the incidence of MACE in elderly AMI patients was analyzed. In all participants, a higher MAGE level was associated with the higher GRACE score (r = 0.335, p < 0.001). The rate of MACE by MAGE tertiles (>3.94 mmol/L, 2.55-3.94 mmol/L or <2.55 mmol/L) was 30.2% vs. 14.8% vs. 8.1%, respectively (p = 0.004); by HbA1c category (≥6.5% vs. <6.5%) was 22.7% vs. 14.4%, respectively (p = 0.148). Elderly AMI patients with a higher MAGE level had a significantly higher cardiac mortality. In multivariable analysis, high MAGE level was significantly associated with incidence of MACE (HR 3.107, 95% CI 1.190-8.117, p = 0.021) even after adjusting for GRACE risk score, but HbA1c was not. The early in-hospital intraday glycemic excursion may be an important predictor of mortality and MACE even stronger than HbA1c in elderly patients after AMI.

  13. The impact of a low glycemic index (GI) breakfast and snack on daily blood glucose profiles and food intake in young Chinese adult males.

    PubMed

    Kaur, Bhupinder; Ranawana, Viren; Teh, Ai-Ling; Henry, C Jeya K

    2015-09-01

    Low glycemic index (GI) foods have been suggested to minimize large fluctuations in blood glucose levels and reduce food intake. However, the majority of studies have been conducted on Caucasian populations with limited data on Asians. The objective of this study was to investigate how the provision of a low GI breakfast and afternoon snack affected daily blood glucose profiles and food intake. In a randomized, controlled crossover non blind design, 11 healthy Chinese male adults (body mass index 22.4 ± 1.3 kg m -2 ) attended two sessions where they consumed either a high or low GI breakfast and afternoon snack, and a standardized buffet lunch. Daily changes in glycemic response (GR) were measured using the Medtronic MiniMed (Northridge, CA) iPro™2 continuous glucose monitoring system (CGMS). The GR was further calculated to obtain the incremental area under the curve (IAUC). Glycemic variability was calculated as mean amplitude of glycemic excursion (MAGE) and energy intake (kcal) was measured quantitatively at the buffet lunch. Compared to the high GI intervention, the low GI intervention significantly reduced the GR following breakfast ( p  = 0.02), lunch ( p  = 0.02) and dinner ( p  = 0.05). The low GI treatment showed a reduction in daily AUC ( p  = 0.03). There was a significant reduction in IAUC after a low GI breakfast compared to the high GI breakfast ( p  = 0.03). The low GI breakfast resulted in a significantly lower food intake at lunch and a resulting decreased energy intake of 285 kcal ( p  = 0.02). The MAGE was significantly lower during the entire low GI treatment ( p  = 0.03). Consumption of a low GI breakfast and afternoon snack was capable of attenuating 24-h blood glucose profiles, minimize glycemic excursions and reduce food intake in healthy Asian males. This simple dietary intervention may be an acceptable approach in improving overall glycemia and energy balance in Asians. NCT02340507.

  14. Test tools and test data for the future EUMETSAT EPS-SG platform

    NASA Astrophysics Data System (ADS)

    Khlystova, Iryna; Sunda, Michela

    2017-04-01

    The EUMETSAT Polar System - Second Generation (EPS-SG) represents Europe's contribution to the future Joint Polar System (JPS), which is planned to be established together with the National Oceanic and Atmospheric Administration (NOAA) of the United States, following on from the Initial Joint Polar System (IJPS). Due to its global coverage and the variety of passive and active sensors on the EPS-SG platform, a significant positive impact on Numerical Weather Prediction (NWP) can be expected for all forecasts based on NWP in the 2020-2040 time frame. It will increase direct socio-economic benefits to Member States and leverage additional benefits through its integration into the JPS and cooperation in the context of CGMS and WMO. For the EUMETSAT will develop the EPS-SG overall system of satellites and the Overall Ground Segment (OGS) and be responsible for the Payload Data Acquisition and Processing (PDAP) system. This will include all the functionality dedicated to the L0, L1 and L2 Operational Processor, for generation of the near-real time L1 and L2 mission central products. Also the European Space Agency will develop the EPS-SG satellites and a number of instruments, with CNES and DLR playing a key role. The general processing chain should be in place and be extensively tested before the first data set is sent from the space platform to the ground. For this, numerous test tools, such as satellite data simulators (IDS) and processors prototypes (GPPs and IPPs) need to be developed and operated before the launch of the satellites. EUMETSAT cooperated with several European agencies in order to provide all the testing items in time. Here, we present the insight into the EPS-SG the logic of the test tools for the generation of the test data and provide insights into the modern space-based mission planning and preparation activities.

  15. Effect of insulin analog initiation therapy on LDL/HDL subfraction profile and HDL associated enzymes in type 2 diabetic patients.

    PubMed

    Aslan, Ibrahim; Kucuksayan, Ertan; Aslan, Mutay

    2013-04-24

    Insulin treatment can lead to good glycemic control and result in improvement of lipid parameters in type 2 diabetic patients. This study was designed to evaluate the effect of insulin analog initiation therapy on low-density lipoprotein (LDL)/ high-density lipoprotein (HDL) sub-fractions and HDL associated enzymes in type 2 diabetic patients during early phase. Twenty four type 2 diabetic patients with glycosylated hemoglobin (HbA1c) levels above 10% despite ongoing combination therapy with sulphonylurea and metformin were selected. Former treatment regimen was continued for the first day followed by substitution of sulphonylurea therapy with different insulin analogs (0.4 U/kg/day) plus metformin. Glycemic profiles were determined over 72 hours by continuous glucose monitoring system (CGMS) and blood samples were obtained from all patients at 24 and 72 hours. Plasma levels of cholesteryl ester transfer protein (CETP), lecithin-cholesterol acyltransferase (LCAT), apolipoprotein B (apoB) and apolipoprotein A-1 (apoA-I) were determined by enzyme-linked immunosorbent assay (ELISA). Measurement of CETP and LCAT activity was performed via fluorometric analysis. Paraoxonase (PON1) enzyme activity was assessed from the rate of enzymatic hydrolysis of phenyl acetate to phenol formation. LDL and HDL subfraction analysis was done by continuous disc polyacrylamide gel electrophoresis. Mean blood glucose, total cholesterol (TC), triglyceride (TG) and very low-density lipoprotein cholesterol (VLDL-C) levels were significantly decreased while HDL-C levels were significantly increased after insulin treatment. Although LDL-C levels were not significantly different before and after insulin initiation therapy a significant increase in LDL-1 subgroup and a significant reduction in atherogenic LDL-3 and LDL-4 subgroups were observed. Insulin analog initiation therapy caused a significant increase in HDL-large, HDL- intermediate and a significant reduction in HDL-small subfractions. CETP protein level and activity was significantly increased while apoB levels were significantly decreased following insulin analog initiation therapy. No significant difference was found in LCAT mass, LCAT activity, apoA-I and PON-1 arylesterase levels following insulin initiation therapy. These findings indicate that insulin analog initiation therapy activates lipid metabolism via up-regulating CETP and shows anti-atherogenic effects by increasing HDL-large and decreasing LDL-3 and LDL-4 subfractions in a short time period.

  16. Insulin Pump and CGM Usage in the United States and Germany

    PubMed Central

    Walsh, John; Roberts, Ruth; Weber, Dietmar; Faber-Heinemann, Gabriele; Heinemann, Lutz

    2015-01-01

    Background: This survey collected and evaluated user responses about routine tasks and preferences regarding insulin pumps and infusion sets (IIS) with comparison of intercountry differences between the United States (US) and Germany (GER), chosen for their large insulin pump populations. Methods: A total of 985 subjects (534 US, 451 GER; 60% female) with type 1 diabetes on pump therapy anonymously answered 20 pump-related questions. US subjects also answered 11 questions about continuous glucose monitoring (CGM) usage. Results: Length of use of insulin cartridges is shorter in US than in GER, mean (SD) 4.3 (5.0) versus 5.3 (3.2) days (P < .001), while the IIS is used longer: 3.3 (1.0) versus 2.7 (1.1) days (P < .001). Lower self-reported HbA1c levels were associated with longer use of insulin cartridges (7.3% for >3 days vs 7.7% for <3 days; P < .01), and with use of an auto-insertion device (vs manual IIS insertion) in the US (7.2% vs 6.9%), but not in GER (7.7% vs 7.9%). Only 47% of pump wearers stated that they were “very satisfied” with their pump (49% US vs 45% GER, ns). However, 98% would recommend the pump to others (95% vs 93%, ns). Analysis of CGM questions showed that 297 (60%) of 496 US responders currently wore one. Of these, 84% said they would recommend CGM to others. CGM wearers who stated they were “very satisfied” with their CGM had lower HbA1c than those who said they were “partly satisfied” (6.9% vs 7.2%). Conclusions: This survey shows interesting differences in real-world use of insulin pumps in 2 large markets, and suggests areas where insulin pumps and CGMs might be improved. PMID:26071425

  17. Effect of a low dose whey/guar preload on glycemic control in people with type 2 diabetes--a randomised controlled trial.

    PubMed

    Clifton, Peter M; Galbraith, Claire; Coles, Leah

    2014-10-25

    Large preloads of protein and fat have been shown to lower glucose after a carbohydrate-rich meal in people with type 2 diabetes but add a considerable energy burden. Low calorie preloads [<5% of daily energy intake] have been tested in this study in people with prediabetes and with type 2 diabetes. This was an unblinded randomised crossover study with two placebo days and two active treatment days. Glucose was measured for 3 hours with fingerprick samples as well as continuous glucose monitoring [CGMS]. Twenty-four subjects with pre-diabetes or moderately controlled type 2 diabetes [fasting glucose < 10 and HbA1c < 8.5%] were recruited. The preload contained 17 g whey protein plus 3 g lactose and 5 g guar, and 1 g flavour material [including sucralose] dissolved in 150 ml cold water or 150 ml cold water with no additives. The breakfast test meal consisted of 2 slices of bread, margarine and jam [3 slices for men] with the test drink 15 minutes beforehand. Peak fingerprick glucose was reduced by 2.1 mmol/L at 45 min [p < 0.0001]. Average fingerprick glucose over 3 hours was reduced by 0.8 mmol/L [p = 0.0003]. There was no difference between those with diabetes or prediabetes or those on medication or not on medication. An 80 kcal whey protein/fibre preload can lower average glucose over 3 hours by 0.8 mmol/L. If used long term before at least two carbohydrate-rich meals/day this preload could lower HbA1c by up to 1%. The trial was registered with the Australian New Zealand Clinical Trials Registry number ACTRN12612001251819.

  18. Chemical composition and anticancer activity of essential oils of Mediterranean sage (Salvia officinalis L.) grown in different environmental conditions.

    PubMed

    Russo, Alessandra; Formisano, Carmen; Rigano, Daniela; Senatore, Felice; Delfine, Sebastiano; Cardile, Venera; Rosselli, Sergio; Bruno, Maurizio

    2013-05-01

    Salvia officinalis L. can be found worldwide and its leaves are commonly used as ingredient in food industry. Sage essential oil is applied in the treatment of a range of diseases and has been shown to possess different biological activities. The objectives of our research were to study the effects of environment on crop, chemical composition and anticancer activity on S. officinalis essential oil. Sage was cultivated at eighteen experimental sites in south-central Italy (Molise) in different growing environments. The essential oils (S1-S18), extracted by hydrodistillation, were analyzed by GC and CG/MS. Results show that the main components were α-thujone, camphor, borneol, γ-muurolene and sclareol for all the samples, but the percentages of these compounds varied depending on environmental factors such as altitude, water availability and pedo-climatic conditions. The growth-inhibitory and proapoptotic effects of the eighteen sage essential oils were evaluated in three human melanoma cell lines, A375, M14, and A2058. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. Whey acerola-flavoured drink submitted Ohmic Heating: Bioactive compounds, antioxidant capacity, thermal behavior, water mobility, fatty acid profile and volatile compounds.

    PubMed

    Cappato, Leandro P; Ferreira, Marcus Vinicius S; Moraes, Jeremias; Pires, Roberto P S; Rocha, Ramon S; Silva, Ramon; Neto, Roberto P C; Tavares, Maria Inês B; Freitas, Mônica Q; Rodrigues, Flavio N; Calado, Veronica M A; Raices, Renata S L; Silva, Marcia C; Cruz, Adriano G

    2018-10-15

    Whey acerola-flavoured drink was subjected to Ohmic Heating (OH) under different operational conditions (45, 60, 80 V at 60 Hz and 10, 100, 1000 Hz with 25 V, 65 °C/30 min) and conventional pasteurization (65 °C/30 min). Bioactive compounds (total phenolics, DPPH, FRAP, ACE levels), fatty acid profile, volatile compounds (CG-MS), thermal behaviors (DSC) and water mobility (TD-NMR) were performed. Reduction of frequency (1000-10 Hz) resulted in a lower bioactive compounds and antioxidant capacity of the samples, except for the DPPH values. Concerning the thermal behaviors, fatty acids profile and volatile compounds, different findings were observed as a function of the parameters used (voltage and frequency). In respect of TD-NMR parameters, OH led to a slightly reduction of the relaxation time when compared to the conventional treatment, suggesting more viscous beverages. Overall, OH may be interesting option to whey acerola-flavoured drink processing. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Chemical composition and biological activity of the essential oil from Helichrysum microphyllum Cambess. ssp. tyrrhenicum Bacch., Brullo e Giusso growing in La Maddalena Archipelago, Sardinia.

    PubMed

    Ornano, Luigi; Venditti, Alessandro; Sanna, Cinzia; Ballero, Mauro; Maggi, Filippo; Lupidi, Giulio; Bramucci, Massimo; Quassinti, Luana; Bianco, Armandodoriano

    2015-01-01

    Helichrysum microphyllum Cambess. subsp. tyrrhenicum Bacch., Brullo e Giusso (Asteraceae), previously known as Helichrysum italicum ssp. microphyllum (Willd.) Nyman, is one of the many endemic species growing in Sardinia, Corsica and Balearic Islands. In the present work the composition of the essential oil obtained from a population of H. microphyllum ssp. thyrrenicum growing in a littoral location of La Maddalena Archipelago was investigated by GC-FID and CG-MS. The major compounds of the oil were the monoterpene ester neryl acetate (18.2%), the oxygenated sesquiterpene 5-eudesmen-11-ol (rosifoliol, 11.3%), the sequiterpene hydrocarbons δ-cadinene (8.4%) and γ-cadinene (6.7%), showing a peculiar composition in comparison with other Sardinian populations. The oil was tested for cytotoxicity on three human tumor cell lines (MDA-MB 231, HCT116 and A375) by MTT assay showing a strong inhibitory activity on human malignant melanoma cells A375 (IC50 of 16 µg/ml). In addition the oil was assessed for antioxidant activity by DPPH and ABTS assay.

  1. Grab and passive sampling applied to pesticide analysis in the São Lourenço river headwater in Campo Verde - MT, Brazil.

    PubMed

    Berton, André; Brugnera, Michelle F; Dores, Eliana F G C

    2018-04-03

    In this study, the quality of surface water in the headwaters of São Lourenço River in Mato Grosso, Brazil, was evaluated in relation to contamination by pesticides. For this purpose, samples were collected between December 2015 and June 2016 by grab sampling and by passive sampling using an integrative polar organic compound sampler installed in the field during four 14-day cycles between March and June 2016. The analyses were performed by gas chromatography (CG/MS) and by liquid chromatography (UPLC-MS/MS). The results showed the detection of two pesticides (atrazine and pyraclostrobin) of the five analyzed by passive sampling and eight active principles among the 20 analyzed (malathion, diuron, carbofuran, carbendazim, trifluralin, imidacloprid, metolachlor, and acetamiprid) by grab sampling. The detection of 10 pesticides, even almost a decade after the beginning of a recovery process of the ciliary forest, confirms the headwaters' vulnerability to these contaminants and passive sampling proved to be an important tool in capturing small concentrations of pesticides constituting an interesting complement to grab sampling.

  2. How Do Inflows and Outflows from Galaxies Create Their Inner Circumgalactic Medium?

    NASA Astrophysics Data System (ADS)

    Bowen, David

    2017-08-01

    We propose using COS to observe 7 QSO sightlines within half a virial radius each of two galaxies in order to probe their circumgalactic mediums (CGMs) along multiple sightlines. Results from higher redshift QSO absorption line surveys suggest that this is the region where most metal line absorbing gas clouds reside, but their origin remains controversial. The two spiral galaxies studied in this proposal are NGC 4565 (the Needle Galaxy) which is highly inclined (i=86 degrees), and NGC 3184, which has a very low inclination (i=9 degrees). Their orientation makes them ideal targets for looking for kinematic and metallicity signatures from outflows along the minor axis, or inflows into the disk along the major axis. For both galaxies, we will measure how HI and metal line column densities change globally with radius, and how the ionzation structure of the absorbers varies with position. We predict that the HI column densities we detect will be similar to the Lyman Limit, or partial-Lyman Limit systems, and that we will be able to measure the gas metallicity in these clouds. These measurements can be used to infer whether the absorbing gas is flowing into the galaxy from the IGM (where the metallicity is lower than in the galaxy) or out of the galaxy (which should be metal enriched). Given that LLS and pLLS have been shown to have a bimodal distribution in their metallicity, we will see which of the two regimes the gas in our galaxies belong to, and even whether the bimodality can be seen in a single galaxy towards different sightlines.

  3. [Effect of CPAP therapy on dynamic glucose level in OSAHS patients with newly diagnosed T2DM].

    PubMed

    Zhao, Lijun; Hui, Peilin; Xie, Yuping; Hou, Yiping; Wei, Xiaoquan; Ma, Wei; Wang, Jinfeng; Zhou, Liya; Zhang, Wenjuan

    2015-11-24

    To investigate the characteristic of dynamic glucose level in obstructive sleep apnea-hypopnea syndrome (OSAHS) patients with newly diagnosed type 2 diabetes mellitus (T2DM) and to evaluate the effect of continuous positive airway pressure (CPAP) treatment on the glucose level. A total of 65 cases of patients with T2DM who were newly diagnosed by oral glucose tolerance test (OGTT) were enrolled from April 2014 to April 2015 in Gansu Provincial Hospital, and divided into simple T2DM group (n=30) and OSAHS with T2DM group (n=35) according to aponea-hypopnea index (AHI) which was monitored by polysomnography (PSG). Their general clinical data were collected, and glucose level of different periods was monitored by continuous glucose moitoring system (CGMS). Changes of glucose level were compared between two groups before and after CPAP treatment. Age, gender proportion, BMI, smoking and drinking history, glycosylated hemoglobin (HbA1c) and blood lipid profile had no significantly difference between two groups. Longer neck circumstance and higher waist-hip ration (WHR), higher systolic blood pressure and diastolic blood pressure, higher fasting plasma glucose (FPG) [(9.4 ± 3.2) vs (7.3 ± 2.1) mmol/L, P=0.028] and fasting insulin (FINS) [(19.2 ± 8.7) vs (11.1 ± 4.7) mU/L, P=0.044] level, more serious homeostasis model assessment insulin resistance (HOMA-IR) were found in OSAHS patients with T2DM when compared to patients in simple T2DM group. The average dynamic glucose level of 24 hours, daytime, nocturnal and sleep time in OSAHS with T2DM group were higher than that in the simple T2DM group (all P<0.05). The alarming times when the average dynamic glucose level of nocturnal time was more than 0.1 mmol·L⁻¹·min⁻¹ in T2DM with OSAHS was more than that in control group (P=0.001). After treatment of CPAP, the level of AHI [(5.9 ± 3.6) vs (56.7 ± 11.4) times/h, P<0.001], average dynamic glucose level of 24 hours, day, nocturnal and sleep time were obviously decreased (all P<0.05); lowest saturation oxygen (LSpO₂) was significantly increased [(92.3 ± 3.7)% vs (81.5 ± 20.2)%, P<0.001]; the alarming times and HOMA-IR were obviously decreased (P=0.019, 0.043). According to multiple linear regression analysis, the AHI (β=0.736, P<0.001) in OSAHS with T2DM group was positively related to the average dynamic glucose level during sleep time, but the LSpO₂(β=-0.889, P<0.001) was negatively correlated. OSAHS patients with newly diagnosed T2DM have higher glucose level than that in simple T2DM patients, and CPAP therapy can obviously decrease the glucose level in newly diagnosed T2DM patients with OSAHS. AHI and LSpO₂may influence the average dynamic glucose level during sleep time.

  4. Chemical composition, antibacterial and antifungal activities of essential oil from Cordia verbenacea DC leaves.

    PubMed

    Rodrigues, Fabiola F G; Oliveira, Liana G S; Rodrigues, Fábio F G; Saraiva, Manuele E; Almeida, Sheyla C X; Cabral, Mario E S; Campos, Adriana R; Costa, Jose Galberto M

    2012-07-01

    Cordia verbenacea is a Brazilian coastal shrub popularly known as "erva baleeira". The essential oil from fresh leaves was obtained by hydrodistillation and analyzed by CG/MS. The main components were identified as β-caryophyllene (25.4%), bicyclogermacrene (11.3%), δ-cadinene (9.%) and α-pinene (9.5%). In this study, the antimicrobial activity of Cordia verbenacea was evaluated. The minimal inhibitory concentration (MIC) of the essential oil was obtained using the broth microdilution assay (from 512 to 8 μg/ml). The results showed that the essential oil presented fungistatic activity against Candida albicans and Candida krusei and antibacterial activity against Gram-positive strains (Staphylococcus aureus and Bacillus cereus) and against multiresistant Gram-negative (Escherichia coli 27), in all tests the MIC was 64 μg/ml. When the essential oil was associated to aminoglycosides (subinhibitory concentrations, MIC/8), a synergic and antagonic activity was verified. The synergic effect was observed to the amikacin association (MIC reduction from 256 mlto 64 μg/ml) in all strains tested. The essential oil of Cordia verbenacea influences the activity of antibiotics and may be used as an adjuvant in antibiotic therapy against respiratory tract bacterial pathogens.

  5. The characteristics of palm oil plantation solid biomass wastes as raw material for bio oil

    NASA Astrophysics Data System (ADS)

    Yanti, RN; Hambali, E.; Pari, G.; Suryani, A.

    2018-03-01

    Indonesia is the largest palm oil plantations estate in the world. It reached 11,30 million hectares in 2015 and increased up to 11,67 million hectares in 2016. The advancement of technology recent, the solid waste of palm oil plantation can be re-produced become bio oil through pyrolysis hydrothermal process and utilized for biofuel. The purpose of this research was to analyze the characteristics of feedstock of bio oil of solid waste of palm oil plantations estate. The feedstock used was derived from solid waste of palm oil plantations in Riau Province. Characteristic analysis of waste oil included chemical compound content (cellulose, hemicellulose, lignin), ultimate analysis (C, H, N, O, S) to know height heating value (HHV). The result of analysis of chemical content showed that solid waste of palm cellulose 31,33 – 66,36 %, hemicellulose 7,54 – 17,94 %, lignin 21,43 - 43,1. The HHV of hydrothermal pyrolysis feedstock was 15,18 kJ/gram - 19,57 kJ/gram. Generally, the solid waste of palm oil plantations estate containing lignocellulose can be utilized as bio oil through hydrothermal pyrolysis. The CG-MS analysis of bio oil indicated hydrocarbon contents such as pentadecane, octadecane, hexadecane and benzene.

  6. Preparation and Characterization of Microencapsulated Phase Change Materials for Use in Building Applications.

    PubMed

    Giro-Paloma, Jessica; Al-Shannaq, Refat; Fernández, Ana Inés; Farid, Mohammed M

    2015-12-26

    A method for preparing and characterizing microencapsulated phase change materials (MPCM) was developed. A comparison with a commercial MPCM is also presented. Both MPCM contained paraffin wax as PCM with acrylic shell. The melting temperature of the PCM was around 21 °C, suitable for building applications. The M-2 (our laboratory made sample) and Micronal ® DS 5008 X (BASF) samples were characterized using SEM, DSC, nano-indentation technique, and Gas Chromatography/Mass spectrometry (GC-MS). Both samples presented a 6 μm average size and a spherical shape. Thermal energy storage (TES) capacities were 111.73 J·g -1 and 99.3 J·g -1 for M-2 and Micronal ® DS 5008 X, respectively. Mechanical characterization of the samples was performed by nano-indentation technique in order to determine the elastic modulus ( E ), load at maximum displacement ( P m ), and displacement at maximum load ( h m ), concluding that M-2 presented slightly better mechanical properties. Finally, an important parameter for considering use in buildings is the release of volatile organic compounds (VOC's). This characteristic was studied at 65 °C by CG-MS. Both samples showed VOC's emission after 10 min of heating, however peaks intensity of VOC's generated from M-2 microcapsules showed a lower concentration than Micronal ® DS 5008 X.

  7. Chemical composition, antibacterial and antifungal activities of essential oil from Cordia verbenacea DC leaves

    PubMed Central

    Rodrigues, Fabiola F. G.; Oliveira, Liana G. S.; Rodrigues, Fábio F. G.; Saraiva, Manuele E.; Almeida, Sheyla C. X.; Cabral, Mario E. S.; Campos, Adriana R.; Costa, Jose Galberto M.

    2012-01-01

    Background: Cordia verbenacea is a Brazilian coastal shrub popularly known as “erva baleeira”. The essential oil from fresh leaves was obtained by hydrodistillation and analyzed by CG/MS. The main components were identified as β-caryophyllene (25.4%), bicyclogermacrene (11.3%), δ-cadinene (9.%) and α-pinene (9.5%). In this study, the antimicrobial activity of Cordia verbenacea was evaluated. Materials and Methods: The minimal inhibitory concentration (MIC) of the essential oil was obtained using the broth microdilution assay (from 512 to 8 μg/ml). Results: The results showed that the essential oil presented fungistatic activity against Candida albicans and Candida krusei and antibacterial activity against Gram-positive strains (Staphylococcus aureus and Bacillus cereus) and against multiresistant Gram-negative (Escherichia coli 27), in all tests the MIC was 64 μg/ml. When the essential oil was associated to aminoglycosides (subinhibitory concentrations, MIC/8), a synergic and antagonic activity was verified. The synergic effect was observed to the amikacin association (MIC reduction from 256 mlto 64 μg/ml) in all strains tested. Conclusion: The essential oil of Cordia verbenacea influences the activity of antibiotics and may be used as an adjuvant in antibiotic therapy against respiratory tract bacterial pathogens. PMID:22923954

  8. Fumigant activity of the Psidium guajava var. pomifera (Myrtaceae) essential oil in Drosophila melanogaster by means of oxidative stress.

    PubMed

    Pinho, Antonio Ivanildo; Wallau, Gabriel Luz; Nunes, Mauro Eugenio Medina; Leite, Nadghia Figueiredo; Tintino, Saulo Relison; da Cruz, Litiele Cezar; da Cunha, Francisco Assis Bezerra; da Costa, José Galberto Martins; Douglas Melo Coutinho, Henrique; Posser, Thais; Franco, Jeferson Luis

    2014-01-01

    The guava fruit, Psidium guajava var. pomifera (Myrtaceae family), is a native plant from South America. Its leaves and fruits are widely used in popular medicine in tropical and subtropical countries. Drosophila melanogaster has been used as one of the main model organisms in genetic studies since the 1900s. The extensive knowledge about this species makes it one of the most suitable organisms to study many aspects of toxic compound effects. Due to the lack of studies on the effects of the bioactive compounds present in the P. guajava var. pomifera essential oil, we performed a phytochemical characterization by CG-MS and evaluated the toxicity induced by the essential oil in the D. melanogaster insect model. In order to understand the biochemical mechanisms of toxicity, changes on the Nrf2 signaling as well as hallmarks of oxidative stress response were followed in the exposed flies. Our results showed that exposure of insects to the P. guajava oil increased mortality and locomotor deficits in parallel with an oxidative stress response signaling. Therefore, it suggested a bioinsecticidal activity for P. guajava volatile compounds by means of oxidative stress. Further studies are ongoing to identify which oil compounds are responsible for such effect.

  9. Fumigant Activity of the Psidium guajava Var. Pomifera (Myrtaceae) Essential Oil in Drosophila melanogaster by Means of Oxidative Stress

    PubMed Central

    Pinho, Antonio Ivanildo; Wallau, Gabriel Luz; Nunes, Mauro Eugenio Medina; Leite, Nadghia Figueiredo; Tintino, Saulo Relison; da Cruz, Litiele Cezar; da Cunha, Francisco Assis Bezerra; da Costa, José Galberto Martins; Douglas Melo Coutinho, Henrique; Posser, Thais

    2014-01-01

    The guava fruit, Psidium guajava var. pomifera (Myrtaceae family), is a native plant from South America. Its leaves and fruits are widely used in popular medicine in tropical and subtropical countries. Drosophila melanogaster has been used as one of the main model organisms in genetic studies since the 1900s. The extensive knowledge about this species makes it one of the most suitable organisms to study many aspects of toxic compound effects. Due to the lack of studies on the effects of the bioactive compounds present in the P. guajava var. pomifera essential oil, we performed a phytochemical characterization by CG-MS and evaluated the toxicity induced by the essential oil in the D. melanogaster insect model. In order to understand the biochemical mechanisms of toxicity, changes on the Nrf2 signaling as well as hallmarks of oxidative stress response were followed in the exposed flies. Our results showed that exposure of insects to the P. guajava oil increased mortality and locomotor deficits in parallel with an oxidative stress response signaling. Therefore, it suggested a bioinsecticidal activity for P. guajava volatile compounds by means of oxidative stress. Further studies are ongoing to identify which oil compounds are responsible for such effect. PMID:25478063

  10. [Glycemic control through physical exercise in type 2 diabetes systematic review].

    PubMed

    Quílez Llopiz, Pablo; Reig García-Galbis, Manuel

    2015-04-01

    In Spain, nearly 14% of the population is diabetic, 95% corresponds to Type 2 Diabetes Mellitus patients. Poor glycemic control increases morbidity and mortality. There are three pillars in the treatment of type 2 diabetes: diet, medication and exercise. However, the potential for prescribing exercise training has not been fully exploited. To analyze the effect of different exercise modalities (AE, RT, Combo, HIIT) on glycemic control in patients with type 2 diabetes mellitus. The reserch was performed in 3 electronic databases (Pubmed, Scopus and Proquest), including publications from 2011 to the present, publications undertaking interventions with AE, RT, Combo or HIIT, and those that measured capillary glucose, CGMS or HbA1c. Of the 386 articles found, 14 met the inclusion criteria. These items were classified according to exercise intervention modality (AE, RT, Combo, HIIT) and whether glycemic control was measured as a result of continued training or 24-48h post-workout. EA, RT, Combo and HIIT show efficacy in glycemic control in both the continuous training and 24-48h post-training. To achieve certain benefits in glycemic control, prescribing a structured frequency, volume and intensity training is required. Combo is the modality that gets better results through continued training. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  11. Effect of processing on the disappearance of pesticide residues in fresh-cut lettuce: Bioavailability and dietary risk.

    PubMed

    Camara, Miguel A; Barba, Alberto; Cermeño, Sandra; Martinez, Gracia; Oliva, Jose

    2017-12-02

    The aim of this research is to establish the processing factors of six pesticides durong the preparation of fresh-cut lettuce and to assess the risk of ingestion of pesticide residues associated with the consumption of the same. A field study was carried out on the dissipation of three insecticides (imidacloprid, tebufenozide, cypermethrin) and three fungicides (metalaxyl, tebuconazole, azoxystrobin) during treatment conditions simulating those used for commercial fresh-cut lettuce. A simultaneous residue analysis method is validated using QuEChERS extraction with acetonitrile and CG-MS and LC-MS/MS analysis. The residues detected after field application never exceed the established Maximum Residue Limits. The processing factors were generally less than 1 (between 0.34 for tebufenozide and 0.53 for imidacloprid), indicating that the process, as a whole, considerably reduces residue levels in processed lettuce compared to fresh lettuce. It is confirmed that cutting, followed by washing and drying, considerably reduces the residues. A matrix effect in the dialyzation of the pesticides is observed and the in vitro study of bioavailability establishes a low percentage of stomach absorption capacity (<15%). The EDI/ADI ratios found in all cases were well below their ADI values, and the dietary exposure assessed (EDI) in fresh-cut lettuce showed no concerns for consumer health.

  12. Monitoring system and methods for a distributed and recoverable digital control system

    NASA Technical Reports Server (NTRS)

    Stange, Kent (Inventor); Hess, Richard (Inventor); Kelley, Gerald B (Inventor); Rogers, Randy (Inventor)

    2010-01-01

    A monitoring system and methods are provided for a distributed and recoverable digital control system. The monitoring system generally comprises two independent monitoring planes within the control system. The first monitoring plane is internal to the computing units in the control system, and the second monitoring plane is external to the computing units. The internal first monitoring plane includes two in-line monitors. The first internal monitor is a self-checking, lock-step-processing monitor with integrated rapid recovery capability. The second internal monitor includes one or more reasonableness monitors, which compare actual effector position with commanded effector position. The external second monitor plane includes two monitors. The first external monitor includes a pre-recovery computing monitor, and the second external monitor includes a post recovery computing monitor. Various methods for implementing the monitoring functions are also disclosed.

  13. 40 CFR 75.16 - Special provisions for monitoring emissions from common, bypass, and multiple stacks for SO2...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... maintain an SO2 continuous emission monitoring system and flow monitoring system in the duct to the common... emission monitoring system and flow monitoring system in the common stack and combine emissions for the... continuous emission monitoring system and flow monitoring system in the duct to the common stack from each...

  14. INDUCTION OF CELL CYCLE ARREST AND APOPTOSIS BY ORMENIS ERIOLEPIS A MORROCAN ENDEMIC PLANT IN VARIOUS HUMAN CANCER CELL LINES.

    PubMed

    Belayachi, Lamiae; Aceves-Luquero, Clara; Merghoub, Nawel; de Mattos, Silvia Fernández; Amzazi, Saaîd; Villalonga, Priam; Bakri, Youssef

    2017-01-01

    Ormenis eriolepis Coss (Asteraceae) is an endemic Moroccan subspecies, traditionally named "Hellala" or "Fergoga". It's usually used for its hypoglycemic effect as well as for the treatment of stomacal pain. As far as we know, there is no scientific exploration of anti tumoral activity of Ormenis eriolepis extracts. In this regard, we performed a screening of organic extracts and fractions in a panel of both hematological and solid cancer cell lines, to evaluate the potential in vitro anti tumoral activity and to elucidate the respective mechanisms that may be responsible for growth arrest and cell death induction. The plant was extracted using organic solvents, and four different extracts were screened on Jurkat, Jeko-1, TK-6, LN229, SW620, U2OS, PC-3 and NIH3T3 cells. Cell viability assays revealed that, the IC50 values were (11,63±5,37μg/ml) for Jurkat, (13,33±1,67μg/ml) for Jeko-1, (41,67±1,98μg/ml) for LN229 and (19,31±4,88μg/ml) for PC-3 cells upon treatment with Oe-DF and Oe-HE respectively. Both the fraction and extract exhibited no effects on TK6 and NIH3T3. Cytometry analysis accompanied by DNA damage signaling protein levels monitoring (p-H2A.X), showed that both the Dichloromethane Fraction and Hexanic extract induce DNA double stranded breaks (DSBs) accompanied by cell cycle arrest in G1 (Jurkat, Jeko -1 and LN22) and G2/M (PC-3) phases which is agreed with the caspase activity observed. Additional experiments with selective inhibitors of stress and survival pathways (JNK, MAPK, Rho, p53, and JAK3) indicated that none of these pathways was significantly involved in apoptosis induction. The bioactive compound analysis by CG/MS indicated that the major compounds in Oe-DF were: Linoleic Acid (15,89%), Podophyllotoxin (17,89%) and Quercetin (22,95%). For Oe-HE the major molecules were: Linoleic Acid (9,76%), α-curcumene (7,07%), α-bisabolol (5,49%), Campesterol (4,41%), Stigmasterol (14,08%) and β-sitosterol (7,49%). Our data suggest that bioactive compounds present in Ormenis eriolepis show significant anti proliferative activity inducing cell cycle arrest and cell death operating through apoptosis pathway.

  15. EPMOSt: An Energy-Efficient Passive Monitoring System for Wireless Sensor Networks

    PubMed Central

    Garcia, Fernando P.; Andrade, Rossana M. C.; Oliveira, Carina T.; de Souza, José Neuman

    2014-01-01

    Monitoring systems are important for debugging and analyzing Wireless Sensor Networks (WSN). In passive monitoring, a monitoring network needs to be deployed in addition to the network to be monitored, named the target network. The monitoring network captures and analyzes packets transmitted by the target network. An energy-efficient passive monitoring system is necessary when we need to monitor a WSN in a real scenario because the lifetime of the monitoring network is extended and, consequently, the target network benefits from the monitoring for a longer time. In this work, we have identified, analyzed and compared the main passive monitoring systems proposed for WSN. During our research, we did not identify any passive monitoring system for WSN that aims to reduce the energy consumption of the monitoring network. Therefore, we propose an Energy-efficient Passive MOnitoring SysTem for WSN named EPMOSt that provides monitoring information using a Simple Network Management Protocol (SNMP) agent. Thus, any management tool that supports the SNMP protocol can be integrated with this monitoring system. Experiments with real sensors were performed in several scenarios. The results obtained show the energy efficiency of the proposed monitoring system and the viability of using it to monitor WSN in real scenarios. PMID:24949639

  16. 40 CFR 63.7747 - How do I apply for alternative monitoring requirements for a continuous emissions monitoring system?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... monitoring requirements for a continuous emissions monitoring system? 63.7747 Section 63.7747 Protection of... apply for alternative monitoring requirements for a continuous emissions monitoring system? (a) You may... prevention technique, a description of the continuous monitoring system or method including appropriate...

  17. 40 CFR 63.7747 - How do I apply for alternative monitoring requirements for a continuous emissions monitoring system?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... monitoring requirements for a continuous emissions monitoring system? 63.7747 Section 63.7747 Protection of... apply for alternative monitoring requirements for a continuous emissions monitoring system? (a) You may... prevention technique, a description of the continuous monitoring system or method including appropriate...

  18. Monitoring Distributed Real-Time Systems: A Survey and Future Directions

    NASA Technical Reports Server (NTRS)

    Goodloe, Alwyn E.; Pike, Lee

    2010-01-01

    Runtime monitors have been proposed as a means to increase the reliability of safety-critical systems. In particular, this report addresses runtime monitors for distributed hard real-time systems. This class of systems has had little attention from the monitoring community. The need for monitors is shown by discussing examples of avionic systems failure. We survey related work in the field of runtime monitoring. Several potential monitoring architectures for distributed real-time systems are presented along with a discussion of how they might be used to monitor properties of interest.

  19. 21 CFR 876.1725 - Gastrointestinal motility monitoring system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Gastrointestinal motility monitoring system. 876... Gastrointestinal motility monitoring system. (a) Identification. A gastrointestinal motility monitoring system is a... esophageal motility monitor and tube, the gastrointestinal motility (electrical) system, and certain...

  20. 21 CFR 876.1725 - Gastrointestinal motility monitoring system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gastrointestinal motility monitoring system. 876... Gastrointestinal motility monitoring system. (a) Identification. A gastrointestinal motility monitoring system is a... esophageal motility monitor and tube, the gastrointestinal motility (electrical) system, and certain...

  1. Smart health monitoring systems: an overview of design and modeling.

    PubMed

    Baig, Mirza Mansoor; Gholamhosseini, Hamid

    2013-04-01

    Health monitoring systems have rapidly evolved during the past two decades and have the potential to change the way health care is currently delivered. Although smart health monitoring systems automate patient monitoring tasks and, thereby improve the patient workflow management, their efficiency in clinical settings is still debatable. This paper presents a review of smart health monitoring systems and an overview of their design and modeling. Furthermore, a critical analysis of the efficiency, clinical acceptability, strategies and recommendations on improving current health monitoring systems will be presented. The main aim is to review current state of the art monitoring systems and to perform extensive and an in-depth analysis of the findings in the area of smart health monitoring systems. In order to achieve this, over fifty different monitoring systems have been selected, categorized, classified and compared. Finally, major advances in the system design level have been discussed, current issues facing health care providers, as well as the potential challenges to health monitoring field will be identified and compared to other similar systems.

  2. 40 CFR 60.2941 - What is my schedule for evaluating continuous emission monitoring systems?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... continuous emission monitoring systems? 60.2941 Section 60.2941 Protection of Environment ENVIRONMENTAL... emission monitoring systems? (a) Conduct annual evaluations of your continuous emission monitoring systems... emission monitoring systems daily and quarterly as specified in appendix F of this part. ...

  3. 30 CFR 27.21 - Methane-monitoring system.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Methane-monitoring system. 27.21 Section 27.21... APPROVAL OF MINING PRODUCTS METHANE-MONITORING SYSTEMS Construction and Design Requirements § 27.21 Methane-monitoring system. (a) A methane-monitoring system shall be so designed that any machine or equipment, which...

  4. 30 CFR 27.21 - Methane-monitoring system.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Methane-monitoring system. 27.21 Section 27.21... APPROVAL OF MINING PRODUCTS METHANE-MONITORING SYSTEMS Construction and Design Requirements § 27.21 Methane-monitoring system. (a) A methane-monitoring system shall be so designed that any machine or equipment, which...

  5. 30 CFR 27.21 - Methane-monitoring system.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Methane-monitoring system. 27.21 Section 27.21... APPROVAL OF MINING PRODUCTS METHANE-MONITORING SYSTEMS Construction and Design Requirements § 27.21 Methane-monitoring system. (a) A methane-monitoring system shall be so designed that any machine or equipment, which...

  6. 30 CFR 27.21 - Methane-monitoring system.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Methane-monitoring system. 27.21 Section 27.21... APPROVAL OF MINING PRODUCTS METHANE-MONITORING SYSTEMS Construction and Design Requirements § 27.21 Methane-monitoring system. (a) A methane-monitoring system shall be so designed that any machine or equipment, which...

  7. 30 CFR 27.21 - Methane-monitoring system.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Methane-monitoring system. 27.21 Section 27.21... APPROVAL OF MINING PRODUCTS METHANE-MONITORING SYSTEMS Construction and Design Requirements § 27.21 Methane-monitoring system. (a) A methane-monitoring system shall be so designed that any machine or equipment, which...

  8. Preparation and Characterization of Microencapsulated Phase Change Materials for Use in Building Applications

    PubMed Central

    Giro-Paloma, Jessica; Al-Shannaq, Refat; Fernández, Ana Inés; Farid, Mohammed M.

    2015-01-01

    A method for preparing and characterizing microencapsulated phase change materials (MPCM) was developed. A comparison with a commercial MPCM is also presented. Both MPCM contained paraffin wax as PCM with acrylic shell. The melting temperature of the PCM was around 21 °C, suitable for building applications. The M-2 (our laboratory made sample) and Micronal® DS 5008 X (BASF) samples were characterized using SEM, DSC, nano-indentation technique, and Gas Chromatography/Mass spectrometry (GC-MS). Both samples presented a 6 μm average size and a spherical shape. Thermal energy storage (TES) capacities were 111.73 J·g−1 and 99.3 J·g−1 for M-2 and Micronal® DS 5008 X, respectively. Mechanical characterization of the samples was performed by nano-indentation technique in order to determine the elastic modulus (E), load at maximum displacement (Pm), and displacement at maximum load (hm), concluding that M-2 presented slightly better mechanical properties. Finally, an important parameter for considering use in buildings is the release of volatile organic compounds (VOC’s). This characteristic was studied at 65 °C by CG-MS. Both samples showed VOC’s emission after 10 min of heating, however peaks intensity of VOC’s generated from M-2 microcapsules showed a lower concentration than Micronal® DS 5008 X. PMID:28787812

  9. Organotin compounds in Brachidontes rodriguezii mussels from the Bahía Blanca Estuary, Argentina.

    PubMed

    Quintas, Pamela Y; Arias, Andrés H; Oliva, Ana L; Domini, Claudia E; Alvarez, Mónica B; Garrido, Mariano; Marcovecchio, Jorge E

    2017-11-01

    Levels of tributyltin and its breakdown compounds, including the first record of monobutyltin (MBT) in history for Latin America, were determined in native mussels (Brachidontes rodriguezii) by means of CG-MS, after extraction/derivatization assisted by ultrasound. The samples were collected in 2013 in Bahía Blanca Estuary (Argentina) at 6 sites, which reflect different levels of maritime activities. Total butyltins (TBts = TBT+ DBT+ MBT) levels ranged from 19.64 to 180.57ng Sn g -1 dry weight. According to the Oslo-Paris commission, the results indicated that 73.9% of mussels could be under biological effects risks associated with TBT pollution. In accordance with the calculated bioaccumulation factors, approximately 56% of samples appeared to have accumulated TBT through the sediments. All sampling sites were shown to be impacted by organotin compounds (OTCs) showing variable levels through seasons, which could be related with the variation of the water temperature. Degradation index analyses suggested aged inputs of TBT possibly under a general degradation process at the area of study. In addition, the occurrence of DBT and MBT could not be uniquely attributed to the degradation pathway of the TBT; in fact, results outlined the possible contribution of some punctual and diffuse sources at the area such as proximity to plastic industries, industrial effluents, sewage outlets and domestic wastewaters. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. 40 CFR 60.3038 - What continuous emission monitoring systems must I install?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... December 9, 2004 Model Rule-Monitoring § 60.3038 What continuous emission monitoring systems must I install? (a) You must install, calibrate, maintain, and operate continuous emission monitoring systems for... system according to the “Monitoring Requirements” in § 60.13. ...

  11. 49 CFR 385.703 - Safety monitoring system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Safety monitoring system. 385.703 Section 385.703... Safety Monitoring System for Non-North American Carriers § 385.703 Safety monitoring system. (a) General... Vehicle Safety Standards (FMVSSs), and Hazardous Materials Regulations (HMRs). (b) Roadside monitoring...

  12. 49 CFR 385.103 - Safety monitoring system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Safety monitoring system. 385.103 Section 385.103... Safety Monitoring System for Mexico-Domiciled Carriers § 385.103 Safety monitoring system. (a) General... Vehicle Safety Standards (FMVSSs), and Hazardous Materials Regulations (HMRs). (b) Roadside monitoring...

  13. 40 CFR 60.3038 - What continuous emission monitoring systems must I install?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... December 9, 2004 Model Rule-Monitoring § 60.3038 What continuous emission monitoring systems must I install? (a) You must install, calibrate, maintain, and operate continuous emission monitoring systems for... system according to the “Monitoring Requirements” in § 60.13. ...

  14. 49 CFR 385.703 - Safety monitoring system.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 5 2011-10-01 2011-10-01 false Safety monitoring system. 385.703 Section 385.703... Safety Monitoring System for Non-North American Carriers § 385.703 Safety monitoring system. (a) General... Vehicle Safety Standards (FMVSSs), and Hazardous Materials Regulations (HMRs). (b) Roadside monitoring...

  15. 49 CFR 385.103 - Safety monitoring system.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 5 2011-10-01 2011-10-01 false Safety monitoring system. 385.103 Section 385.103... Safety Monitoring System for Mexico-Domiciled Carriers § 385.103 Safety monitoring system. (a) General... Vehicle Safety Standards (FMVSSs), and Hazardous Materials Regulations (HMRs). (b) Roadside monitoring...

  16. 29 CFR 1954.2 - Monitoring system.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 9 2014-07-01 2014-07-01 false Monitoring system. 1954.2 Section 1954.2 Labor Regulations...) PROCEDURES FOR THE EVALUATION AND MONITORING OF APPROVED STATE PLANS General § 1954.2 Monitoring system. (a... Act, the Assistant Secretary has established a State Program Performance Monitoring System. Evaluation...

  17. 29 CFR 1954.2 - Monitoring system.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 9 2013-07-01 2013-07-01 false Monitoring system. 1954.2 Section 1954.2 Labor Regulations...) PROCEDURES FOR THE EVALUATION AND MONITORING OF APPROVED STATE PLANS General § 1954.2 Monitoring system. (a... Act, the Assistant Secretary has established a State Program Performance Monitoring System. Evaluation...

  18. 29 CFR 1954.2 - Monitoring system.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 9 2012-07-01 2012-07-01 false Monitoring system. 1954.2 Section 1954.2 Labor Regulations...) PROCEDURES FOR THE EVALUATION AND MONITORING OF APPROVED STATE PLANS General § 1954.2 Monitoring system. (a... Act, the Assistant Secretary has established a State Program Performance Monitoring System. Evaluation...

  19. 29 CFR 1954.2 - Monitoring system.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 9 2010-07-01 2010-07-01 false Monitoring system. 1954.2 Section 1954.2 Labor Regulations...) PROCEDURES FOR THE EVALUATION AND MONITORING OF APPROVED STATE PLANS General § 1954.2 Monitoring system. (a... Act, the Assistant Secretary has established a State Program Performance Monitoring System. Evaluation...

  20. 29 CFR 1954.2 - Monitoring system.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 9 2011-07-01 2011-07-01 false Monitoring system. 1954.2 Section 1954.2 Labor Regulations...) PROCEDURES FOR THE EVALUATION AND MONITORING OF APPROVED STATE PLANS General § 1954.2 Monitoring system. (a... Act, the Assistant Secretary has established a State Program Performance Monitoring System. Evaluation...

  1. 40 CFR 60.3040 - What is my schedule for evaluating continuous emission monitoring systems?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... continuous emission monitoring systems? 60.3040 Section 60.3040 Protection of Environment ENVIRONMENTAL... continuous emission monitoring systems? (a) Conduct annual evaluations of your continuous emission monitoring... emission monitoring systems daily and quarterly as specified in appendix F of this part. ...

  2. 40 CFR 60.2939 - What continuous emission monitoring systems must I install?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... and Qualification Monitoring § 60.2939 What continuous emission monitoring systems must I install? (a) You must install, calibrate, maintain, and operate continuous emission monitoring systems for carbon... carbon monoxide. (b) You must install, evaluate, and operate each continuous emission monitoring system...

  3. 40 CFR 60.2939 - What continuous emission monitoring systems must I install?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... and Qualification Monitoring § 60.2939 What continuous emission monitoring systems must I install? (a) You must install, calibrate, maintain, and operate continuous emission monitoring systems for carbon... carbon monoxide. (b) You must install, evaluate, and operate each continuous emission monitoring system...

  4. Wireless patient monitoring system for a moving-actuator type artificial heart.

    PubMed

    Nam, K W; Chung, J; Choi, S W; Sun, K; Min, B G

    2006-10-01

    In this study, we developed a wireless monitoring system for outpatients equipped with a moving-actuator type pulsatile bi-ventricular assist device, AnyHeart. The developed monitoring system consists of two parts; a Bluetooth-based short-distance self-monitoring system that can monitor and control the operating status of a VAD using a Bluetooth-embedded personal digital assistant or a personal computer within a distance of 10 meters, and a cellular network-based remote monitoring system that can continuously monitor and control the operating status of AnyHeart at any location. Results of in vitro experiments demonstrate the developed system's ability to monitor the operational status of an implanted AnyHeart.

  5. Hybrid Wireless Hull Monitoring System for Naval Combat Vessels

    DTIC Science & Technology

    2010-03-01

    Payload Data Acquisition System (SPDAS) is designed by the Technology Management Group, Inc. ( TMG ). In its design, the monitoring system is intended...monitoring system custom designed by TMG for the U.S. Navy. The Scientific Payload Data Acquisition System (SPDAS) is a wired hull monitoring system

  6. 40 CFR 265.91 - Ground-water monitoring system.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 26 2011-07-01 2011-07-01 false Ground-water monitoring system. 265.91... DISPOSAL FACILITIES Ground-Water Monitoring § 265.91 Ground-water monitoring system. (a) A ground-water monitoring system must be capable of yielding ground-water samples for analysis and must consist of: (1...

  7. 33 CFR 157.12 - Oil discharge monitoring and control system.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Oil discharge monitoring and... CARRYING OIL IN BULK Design, Equipment, and Installation § 157.12 Oil discharge monitoring and control system. (a) Each vessel must have an oil discharge monitoring and control system (monitoring system) that...

  8. 33 CFR 157.12 - Oil discharge monitoring and control system.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Oil discharge monitoring and... CARRYING OIL IN BULK Design, Equipment, and Installation § 157.12 Oil discharge monitoring and control system. (a) Each vessel must have an oil discharge monitoring and control system (monitoring system) that...

  9. 33 CFR 157.12 - Oil discharge monitoring and control system.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Oil discharge monitoring and... CARRYING OIL IN BULK Design, Equipment, and Installation § 157.12 Oil discharge monitoring and control system. (a) Each vessel must have an oil discharge monitoring and control system (monitoring system) that...

  10. 33 CFR 157.12 - Oil discharge monitoring and control system.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Oil discharge monitoring and... CARRYING OIL IN BULK Design, Equipment, and Installation § 157.12 Oil discharge monitoring and control system. (a) Each vessel must have an oil discharge monitoring and control system (monitoring system) that...

  11. 33 CFR 157.12 - Oil discharge monitoring and control system.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Oil discharge monitoring and... CARRYING OIL IN BULK Design, Equipment, and Installation § 157.12 Oil discharge monitoring and control system. (a) Each vessel must have an oil discharge monitoring and control system (monitoring system) that...

  12. 40 CFR 258.51 - Ground-water monitoring systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 25 2014-07-01 2014-07-01 false Ground-water monitoring systems. 258... CRITERIA FOR MUNICIPAL SOLID WASTE LANDFILLS Ground-Water Monitoring and Corrective Action § 258.51 Ground-water monitoring systems. (a) A ground-water monitoring system must be installed that consists of a...

  13. 40 CFR 258.51 - Ground-water monitoring systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 26 2012-07-01 2011-07-01 true Ground-water monitoring systems. 258.51... FOR MUNICIPAL SOLID WASTE LANDFILLS Ground-Water Monitoring and Corrective Action § 258.51 Ground-water monitoring systems. (a) A ground-water monitoring system must be installed that consists of a...

  14. 40 CFR 265.91 - Ground-water monitoring system.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 27 2012-07-01 2012-07-01 false Ground-water monitoring system. 265.91... DISPOSAL FACILITIES Ground-Water Monitoring § 265.91 Ground-water monitoring system. (a) A ground-water monitoring system must be capable of yielding ground-water samples for analysis and must consist of: (1...

  15. 40 CFR 265.91 - Ground-water monitoring system.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 27 2013-07-01 2013-07-01 false Ground-water monitoring system. 265.91... DISPOSAL FACILITIES Ground-Water Monitoring § 265.91 Ground-water monitoring system. (a) A ground-water monitoring system must be capable of yielding ground-water samples for analysis and must consist of: (1...

  16. 40 CFR 257.22 - Ground-water monitoring systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 25 2014-07-01 2014-07-01 false Ground-water monitoring systems. 257... Waste Disposal Units Ground-Water Monitoring and Corrective Action § 257.22 Ground-water monitoring systems. (a) A ground-water monitoring system must be installed that consists of a sufficient number of...

  17. 40 CFR 265.91 - Ground-water monitoring system.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 26 2014-07-01 2014-07-01 false Ground-water monitoring system. 265.91... DISPOSAL FACILITIES Ground-Water Monitoring § 265.91 Ground-water monitoring system. (a) A ground-water monitoring system must be capable of yielding ground-water samples for analysis and must consist of: (1...

  18. 40 CFR 258.51 - Ground-water monitoring systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Ground-water monitoring systems. 258... CRITERIA FOR MUNICIPAL SOLID WASTE LANDFILLS Ground-Water Monitoring and Corrective Action § 258.51 Ground-water monitoring systems. (a) A ground-water monitoring system must be installed that consists of a...

  19. 40 CFR 257.22 - Ground-water monitoring systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Ground-water monitoring systems. 257... Waste Disposal Units Ground-Water Monitoring and Corrective Action § 257.22 Ground-water monitoring systems. (a) A ground-water monitoring system must be installed that consists of a sufficient number of...

  20. 40 CFR 60.1250 - What is my schedule for evaluating continuous emission monitoring systems?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... continuous emission monitoring systems? 60.1250 Section 60.1250 Protection of Environment ENVIRONMENTAL... Continuous Emission Monitoring § 60.1250 What is my schedule for evaluating continuous emission monitoring systems? (a) Conduct annual evaluations of your continuous emission monitoring systems no more than 13...

  1. 40 CFR 60.1235 - How are the data from the continuous emission monitoring systems used?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... emission monitoring systems used? 60.1235 Section 60.1235 Protection of Environment ENVIRONMENTAL... Continuous Emission Monitoring § 60.1235 How are the data from the continuous emission monitoring systems used? You must use data from the continuous emission monitoring systems for sulfur dioxide, nitrogen...

  2. 40 CFR 60.1235 - How are the data from the continuous emission monitoring systems used?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... emission monitoring systems used? 60.1235 Section 60.1235 Protection of Environment ENVIRONMENTAL... Continuous Emission Monitoring § 60.1235 How are the data from the continuous emission monitoring systems used? You must use data from the continuous emission monitoring systems for sulfur dioxide, nitrogen...

  3. 40 CFR 62.15220 - What additional requirements must I meet for the operation of my continuous emission monitoring...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... meet for the operation of my continuous emission monitoring systems and continuous opacity monitoring system? 62.15220 Section 62.15220 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... the operation of my continuous emission monitoring systems and continuous opacity monitoring system...

  4. 40 CFR 62.15220 - What additional requirements must I meet for the operation of my continuous emission monitoring...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... meet for the operation of my continuous emission monitoring systems and continuous opacity monitoring system? 62.15220 Section 62.15220 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... the operation of my continuous emission monitoring systems and continuous opacity monitoring system...

  5. A remote drip infusion monitoring system employing Bluetooth.

    PubMed

    Amano, Hikaru; Ogawa, Hidekuni; Maki, Hiromichi; Tsukamoto, Sosuke; Yonezawa, Yoshiharu; Caldwell, W Morton

    2012-01-01

    We have developed a remote drip infusion monitoring system for use in hospitals. The system consists of several infusion monitoring devices and a central monitor. The infusion monitoring device employing a Bluetooth module can detect the drip infusion rate and an empty infusion solution bag, and then these data are sent to the central monitor placed at the nurses' station via the Bluetooth. The central monitor receives the data from several infusion monitoring devices and then displays graphically them. Therefore, the developed system can monitor intensively the drip infusion situation of the several patients at the nurses' station.

  6. The future of remote ECG monitoring systems.

    PubMed

    Guo, Shu-Li; Han, Li-Na; Liu, Hong-Wei; Si, Quan-Jin; Kong, De-Feng; Guo, Fu-Su

    2016-09-01

    Remote ECG monitoring systems are becoming commonplace medical devices for remote heart monitoring. In recent years, remote ECG monitoring systems have been applied in the monitoring of various kinds of heart diseases, and the quality of the transmission and reception of the ECG signals during remote process kept advancing. However, there remains accompanying challenges. This report focuses on the three components of the remote ECG monitoring system: patient (the end user), the doctor workstation, and the remote server, reviewing and evaluating the imminent challenges on the wearable systems, packet loss in remote transmission, portable ECG monitoring system, patient ECG data collection system, and ECG signals transmission including real-time processing ST segment, R wave, RR interval and QRS wave, etc. This paper tries to clarify the future developmental strategies of the ECG remote monitoring, which can be helpful in guiding the research and development of remote ECG monitoring.

  7. 40 CFR 60.1270 - What is required for my continuous opacity monitoring system and how are the data used?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... opacity monitoring system and how are the data used? 60.1270 Section 60.1270 Protection of Environment... Continuous Emission Monitoring § 60.1270 What is required for my continuous opacity monitoring system and how... system. (b) Install, evaluate, and operate each continuous opacity monitoring system according to § 60.13...

  8. HyperCard Monitor System.

    ERIC Educational Resources Information Center

    Harris, Julian; Maurer, Hermann

    An investigation into high level event monitoring within the scope of a well-known multimedia application, HyperCard--a program on the Macintosh computer, is carried out. A monitoring system is defined as a system which automatically monitors usage of some activity and gathers statistics based on what is has observed. Monitor systems can give the…

  9. 40 CFR 60.1765 - What additional requirements must I meet for the operation of my continuous emission monitoring...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... meet for the operation of my continuous emission monitoring systems and continuous opacity monitoring system? 60.1765 Section 60.1765 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... continuous emission monitoring systems and continuous opacity monitoring system? Use the required span values...

  10. 40 CFR 60.1765 - What additional requirements must I meet for the operation of my continuous emission monitoring...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... meet for the operation of my continuous emission monitoring systems and continuous opacity monitoring system? 60.1765 Section 60.1765 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... continuous emission monitoring systems and continuous opacity monitoring system? Use the required span values...

  11. Development of living body information monitoring system

    NASA Astrophysics Data System (ADS)

    Sakamoto, Hidetoshi; Ohbuchi, Yoshifumi; Torigoe, Ippei; Miyagawa, Hidekazu; Murayama, Nobuki; Hayashida, Yuki; Igasaki, Tomohiko

    2010-03-01

    The easy monitoring systems of contact and non-contact living body information for preventing the the Sudden Infant Death Syndrome (SIDS) were proposed as an alternative monitoring system of the infant's vital information. As for the contact monitoring system, respiration sensor, ECG electrodes, thermistor and IC signal processor were integrated into babies' nappy holder. This contact-monitoring unit has RF transmission function and the obtained data are analyzed in real time by PC. In non-contact mortaring system, the infrared thermo camera was used. The surrounding of the infant's mouth and nose is monitored and the respiration rate is obtained by thermal image processing of its temperature change image of expired air. This proposed system of in-sleep infant's vital information monitoring system and unit are very effective as not only infant's condition monitoring but also nursing person's one.

  12. Development of living body information monitoring system

    NASA Astrophysics Data System (ADS)

    Sakamoto, Hidetoshi; Ohbuchi, Yoshifumi; Torigoe, Ippei; Miyagawa, Hidekazu; Murayama, Nobuki; Hayashida, Yuki; Igasaki, Tomohiko

    2009-12-01

    The easy monitoring systems of contact and non-contact living body information for preventing the the Sudden Infant Death Syndrome (SIDS) were proposed as an alternative monitoring system of the infant's vital information. As for the contact monitoring system, respiration sensor, ECG electrodes, thermistor and IC signal processor were integrated into babies' nappy holder. This contact-monitoring unit has RF transmission function and the obtained data are analyzed in real time by PC. In non-contact mortaring system, the infrared thermo camera was used. The surrounding of the infant's mouth and nose is monitored and the respiration rate is obtained by thermal image processing of its temperature change image of expired air. This proposed system of in-sleep infant's vital information monitoring system and unit are very effective as not only infant's condition monitoring but also nursing person's one.

  13. 30 CFR 77.312 - Fail safe monitoring systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Fail safe monitoring systems. 77.312 Section 77... Thermal Dryers § 77.312 Fail safe monitoring systems. Thermal dryer systems and controls shall be protected by a fail safe monitoring system which will safely shut down the system and any related equipment...

  14. 30 CFR 77.312 - Fail safe monitoring systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Fail safe monitoring systems. 77.312 Section 77... Thermal Dryers § 77.312 Fail safe monitoring systems. Thermal dryer systems and controls shall be protected by a fail safe monitoring system which will safely shut down the system and any related equipment...

  15. 30 CFR 77.312 - Fail safe monitoring systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Fail safe monitoring systems. 77.312 Section 77... Thermal Dryers § 77.312 Fail safe monitoring systems. Thermal dryer systems and controls shall be protected by a fail safe monitoring system which will safely shut down the system and any related equipment...

  16. 30 CFR 77.312 - Fail safe monitoring systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fail safe monitoring systems. 77.312 Section 77... Thermal Dryers § 77.312 Fail safe monitoring systems. Thermal dryer systems and controls shall be protected by a fail safe monitoring system which will safely shut down the system and any related equipment...

  17. 30 CFR 77.312 - Fail safe monitoring systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Fail safe monitoring systems. 77.312 Section 77... Thermal Dryers § 77.312 Fail safe monitoring systems. Thermal dryer systems and controls shall be protected by a fail safe monitoring system which will safely shut down the system and any related equipment...

  18. Integrated photovoltaic (PV) monitoring system

    NASA Astrophysics Data System (ADS)

    Mahinder Singh, Balbir Singh; Husain, NurSyahidah; Mohamed, Norani Muti

    2012-09-01

    The main aim of this research work is to design an accurate and reliable monitoring system to be integrated with solar electricity generating system. The performance monitoring system is required to ensure that the PVEGS is operating at an optimum level. The PV monitoring system is able to measure all the important parameters that determine an optimum performance. The measured values are recorded continuously, as the data acquisition system is connected to a computer, and data is stored at fixed intervals. The data can be locally used and can also be transmitted via internet. The data that appears directly on the local monitoring system is displayed via graphical user interface that was created by using Visual basic and Apache software was used for data transmission The accuracy and reliability of the developed monitoring system was tested against the data that captured simultaneously by using a standard power quality analyzer device. The high correlation which is 97% values indicates the level of accuracy of the monitoring system. The aim of leveraging on a system for continuous monitoring system is achieved, both locally, and can be viewed simultaneously at a remote system.

  19. 40 CFR 75.10 - General operating requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... continuous emission monitoring system and a flow monitoring system with an automated data acquisition and handling system for measuring and recording SO2 concentration (in ppm), volumetric gas flow (in scfh), and... emission monitoring system and a flow monitoring system with an automated data acquisition and handling...

  20. 21 CFR 884.2800 - Computerized Labor Monitoring System.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Computerized Labor Monitoring System. 884.2800... Devices § 884.2800 Computerized Labor Monitoring System. (a) Identification. A computerized labor monitoring system is a system intended to continuously measure cervical dilation and fetal head descent and...

  1. 40 CFR 65.161 - Continuous records and monitoring system data handling.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Routing to a Fuel Gas System or a Process § 65.161 Continuous records and monitoring system data handling...) Monitoring system breakdowns, repairs, preventive maintenance, calibration checks, and zero (low-level) and... section unless an alternative monitoring or recordkeeping system has been requested and approved under...

  2. 40 CFR 65.161 - Continuous records and monitoring system data handling.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Routing to a Fuel Gas System or a Process § 65.161 Continuous records and monitoring system data handling...) Monitoring system breakdowns, repairs, preventive maintenance, calibration checks, and zero (low-level) and... section unless an alternative monitoring or recordkeeping system has been requested and approved under...

  3. 40 CFR 75.13 - Specific provisions for monitoring CO2 emissions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Specific provisions for monitoring CO2... monitoring CO2 emissions. (a) CO 2 continuous emission monitoring system. If the owner or operator chooses to... operating requirements in § 75.10 for a CO2 continuous emission monitoring system and flow monitoring system...

  4. 40 CFR 75.13 - Specific provisions for monitoring CO2 emissions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 16 2011-07-01 2011-07-01 false Specific provisions for monitoring CO2... monitoring CO2 emissions. (a) CO 2 continuous emission monitoring system. If the owner or operator chooses to... operating requirements in § 75.10 for a CO2 continuous emission monitoring system and flow monitoring system...

  5. 40 CFR 75.13 - Specific provisions for monitoring CO2 emissions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 17 2012-07-01 2012-07-01 false Specific provisions for monitoring CO2... monitoring CO2 emissions. (a) CO 2 continuous emission monitoring system. If the owner or operator chooses to... operating requirements in § 75.10 for a CO2 continuous emission monitoring system and flow monitoring system...

  6. Use of Low-Cost Acquisition Systems with an Embedded Linux Device for Volcanic Monitoring

    PubMed Central

    Moure, David; Torres, Pedro; Casas, Benito; Toma, Daniel; Blanco, María José; Del Río, Joaquín; Manuel, Antoni

    2015-01-01

    This paper describes the development of a low-cost multiparameter acquisition system for volcanic monitoring that is applicable to gravimetry and geodesy, as well as to the visual monitoring of volcanic activity. The acquisition system was developed using a System on a Chip (SoC) Broadcom BCM2835 Linux operating system (based on DebianTM) that allows for the construction of a complete monitoring system offering multiple possibilities for storage, data-processing, configuration, and the real-time monitoring of volcanic activity. This multiparametric acquisition system was developed with a software environment, as well as with different hardware modules designed for each parameter to be monitored. The device presented here has been used and validated under different scenarios for monitoring ocean tides, ground deformation, and gravity, as well as for monitoring with images the island of Tenerife and ground deformation on the island of El Hierro. PMID:26295394

  7. Use of Low-Cost Acquisition Systems with an Embedded Linux Device for Volcanic Monitoring.

    PubMed

    Moure, David; Torres, Pedro; Casas, Benito; Toma, Daniel; Blanco, María José; Del Río, Joaquín; Manuel, Antoni

    2015-08-19

    This paper describes the development of a low-cost multiparameter acquisition system for volcanic monitoring that is applicable to gravimetry and geodesy, as well as to the visual monitoring of volcanic activity. The acquisition system was developed using a System on a Chip (SoC) Broadcom BCM2835 Linux operating system (based on DebianTM) that allows for the construction of a complete monitoring system offering multiple possibilities for storage, data-processing, configuration, and the real-time monitoring of volcanic activity. This multiparametric acquisition system was developed with a software environment, as well as with different hardware modules designed for each parameter to be monitored. The device presented here has been used and validated under different scenarios for monitoring ocean tides, ground deformation, and gravity, as well as for monitoring with images the island of Tenerife and ground deformation on the island of El Hierro.

  8. Systems safety monitoring using the National Full-Scale Aerodynamic Complex Bar Chart Monitor

    NASA Technical Reports Server (NTRS)

    Jung, Oscar

    1990-01-01

    Attention is given to the Bar Chart Monitor system designed for safety monitoring of all model and facility test-related articles in wind tunnels. The system's salient features and its integration into the data acquisition system are discussed.

  9. 40 CFR 75.40 - General demonstration requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) CONTINUOUS EMISSION MONITORING Alternative Monitoring Systems § 75.40 General demonstration... continuous emission monitoring system may apply to the Administrator for approval of an alternative monitoring system (or system component) to determine average hourly emission data for SO2, NOX, and/or...

  10. Clinical Impact of Accurate Point-of-Care Glucose Monitoring for Tight Glycemic Control in Severely Burned Children.

    PubMed

    Tran, Nam K; Godwin, Zachary R; Steele, Amanda N; Wolf, Steven E; Palmieri, Tina L

    2016-09-01

    The goal of this study was to retrospectively evaluate the clinical impact of an accurate autocorrecting blood glucose monitoring system in children with severe burns. Blood glucose monitoring system accuracy is essential for providing appropriate intensive insulin therapy and achieving tight glycemic control in critically ill patients. Unfortunately, few comparison studies have been performed to evaluate the clinical impact of accurate blood glucose monitoring system monitoring in the high-risk pediatric burn population. Retrospective analysis of an electronic health record system. Pediatric burn ICU at an academic medical center. Children (aged < 18 yr) with severe burns (≥ 20% total body surface area) receiving intensive insulin therapy guided by either a noncorrecting (blood glucose monitoring system-1) or an autocorrecting blood glucose monitoring system (blood glucose monitoring system-2). Patient demographics, insulin rates, and blood glucose monitoring system measurements were collected. The frequency of hypoglycemia and glycemic variability was compared between the two blood glucose monitoring system groups. A total of 122 patient charts from 2001 to 2014 were reviewed. Sixty-three patients received intensive insulin therapy using blood glucose monitoring system-1 and 59 via blood glucose monitoring system-2. Patient demographics were similar between the two groups. Mean insulin infusion rates (5.1 ± 3.8 U/hr; n = 535 paired measurements vs 2.4 ± 1.3 U/hr; n = 511 paired measurements; p < 0.001), glycemic variability, and frequency of hypoglycemic events (90 vs 12; p < 0.001) were significantly higher in blood glucose monitoring system-1-treated patients. Compared with laboratory measurements, blood glucose monitoring system-2 yielded the most accurate results (mean ± SD bias: -1.7 ± 6.9 mg/dL [-0.09 ± 0.4 mmol/L] vs 7.4 ± 13.5 mg/dL [0.4 ± 0.7 mmol/L]). Blood glucose monitoring system-2 patients achieve glycemic control more quickly (5.7 ± 4.3 vs 13.1 ± 6.9 hr; p< 0.001) and stayed within the target glycemic control range longer compared with blood glucose monitoring system-1 patients (85.2% ± 13.9% vs 57.9% ± 29.1%; p < 0.001). Accurate autocorrecting blood glucose monitoring system optimizes intensive insulin therapy, improves tight glycemic control, and reduces the risk of hypoglycemia and glycemic variability. The use of an autocorrecting blood glucose monitoring system for intensive insulin therapy may improve glycemic control in severely burned children.

  11. 40 CFR 75.24 - Out-of-control periods and adjustment for system bias.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... § 75.24 Out-of-control periods and adjustment for system bias. (a) If an out-of-control period occurs... monitor or continuous emission monitoring system is out-of-control, any data recorded by the monitor or... pursuant to § 75.32 of this part. (c) When a monitor or continuous emission monitoring system is out-of...

  12. Coma Patient Monitoring System Using Image Processing

    NASA Astrophysics Data System (ADS)

    Sankalp, Meenu

    2011-12-01

    COMA PATIENT MONITORING SYSTEM provides high quality healthcare services in the near future. To provide more convenient and comprehensive medical monitoring in big hospitals since it is tough job for medical personnel to monitor each patient for 24 hours.. The latest development in patient monitoring system can be used in Intensive Care Unit (ICU), Critical Care Unit (CCU), and Emergency Rooms of hospital. During treatment, the patient monitor is continuously monitoring the coma patient to transmit the important information. Also in the emergency cases, doctor are able to monitor patient condition efficiently to reduce time consumption, thus it provides more effective healthcare system. So due to importance of patient monitoring system, the continuous monitoring of the coma patient can be simplified. This paper investigates about the effects seen in the patient using "Coma Patient Monitoring System" which is a very advanced product related to physical changes in body movement of the patient and gives Warning in form of alarm and display on the LCD in less than one second time. It also passes a sms to a person sitting at the distant place if there exists any movement in any body part of the patient. The model for the system uses Keil software for the software implementation of the developed system.

  13. On the matter of the reliability of the chemical monitoring system based on the modern control and monitoring devices

    NASA Astrophysics Data System (ADS)

    Andriushin, A. V.; Dolbikova, N. S.; Kiet, S. V.; Merzlikina, E. I.; Nikitina, I. S.

    2017-11-01

    The reliability of the main equipment of any power station depends on the correct water chemistry. In order to provide it, it is necessary to monitor the heat carrier quality, which, in its turn, is provided by the chemical monitoring system. Thus, the monitoring system reliability plays an important part in providing reliability of the main equipment. The monitoring system reliability is determined by the reliability and structure of its hardware and software consisting of sensors, controllers, HMI and so on [1,2]. Workers of a power plant dealing with the measuring equipment must be informed promptly about any breakdowns in the monitoring system, in this case they are able to remove the fault quickly. A computer consultant system for personnel maintaining the sensors and other chemical monitoring equipment can help to notice faults quickly and identify their possible causes. Some technical solutions for such a system are considered in the present paper. The experimental results were obtained on the laboratory and experimental workbench representing a physical model of a part of the chemical monitoring system.

  14. Physiologic monitoring. A guide to networking your monitoring systems.

    PubMed

    2011-10-01

    There are many factors to consider when choosing a physiologic monitoring system. not only should these systems perform well clinically, but they should also be able to exchange data with other information systems. We discuss some of the ins and outs of physiologic monitoring system networking and highlight eight product lines from seven suppliers.

  15. Shared performance monitor in a multiprocessor system

    DOEpatents

    Chiu, George; Gara, Alan G; Salapura, Valentina

    2014-12-02

    A performance monitoring unit (PMU) and method for monitoring performance of events occurring in a multiprocessor system. The multiprocessor system comprises a plurality of processor devices units, each processor device for generating signals representing occurrences of events in the processor device, and, a single shared counter resource for performance monitoring. The performance monitor unit is shared by all processor cores in the multiprocessor system. The PMU is further programmed to monitor event signals issued from non-processor devices.

  16. 21 CFR 884.2800 - Computerized Labor Monitoring System.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... monitoring system is a system intended to continuously measure cervical dilation and fetal head descent and... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Computerized Labor Monitoring System. 884.2800... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Monitoring...

  17. 21 CFR 884.2800 - Computerized Labor Monitoring System.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... monitoring system is a system intended to continuously measure cervical dilation and fetal head descent and... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Computerized Labor Monitoring System. 884.2800... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Monitoring...

  18. 21 CFR 884.2800 - Computerized Labor Monitoring System.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... monitoring system is a system intended to continuously measure cervical dilation and fetal head descent and... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Computerized Labor Monitoring System. 884.2800... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Monitoring...

  19. Procedure 5 Quality Assurance Requirements For Vapor Phase Mercury Continuous Emissions Monitoring Systems And Sorbent Trap Monitoring Systems Used For Compliance Determination At Stationary Sources

    EPA Pesticide Factsheets

    Promulgated quality assurance Procedure 5 Quality Assurance Requirements For Vapor Phase Mercury Continuous Emissions Monitoring Systems And Sorbent Trap Monitoring Systems Used For Compliance Determination At Stationary Sources

  20. 40 CFR 60.2941 - What is my schedule for evaluating continuous emission monitoring systems?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... continuous emission monitoring systems? 60.2941 Section 60.2941 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES... emission monitoring systems? (a) Conduct annual evaluations of your continuous emission monitoring systems...

  1. 77 FR 18709 - Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-28

    ... Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources AGENCY... direct final rule titled ``Quality Assurance Requirements for Continuous Opacity Monitoring Systems at...--Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources Docket, EPA...

  2. A remote condition monitoring system for wind-turbine based DG systems

    NASA Astrophysics Data System (ADS)

    Ma, X.; Wang, G.; Cross, P.; Zhang, X.

    2012-05-01

    In this paper, a remote condition monitoring system is proposed, which fundamentally consists of real-time monitoring modules on the plant side, a remote support centre and the communications between them. The paper addresses some of the key issues related on the monitoring system, including i) the implementation and configuration of a VPN connection, ii) an effective database system to be able to handle huge amount of monitoring data, and iii) efficient data mining techniques to convert raw data into useful information for plant assessment. The preliminary results have demonstrated that the proposed system is practically feasible and can be deployed to monitor the emerging new energy generation systems.

  3. Demonstration of subsidence monitoring system

    NASA Astrophysics Data System (ADS)

    Conroy, P. J.; Gyarmaty, J. H.; Pearson, M. L.

    1981-06-01

    Data on coal mine subsidence were studied as a basis for the development of subsidence control technology. Installation, monitoring, and evaluation of three subsidence monitoring instrument systems were examined: structure performance, performance of supported systems, and performance of caving systems. Objectives of the instrument program were: (1) to select, test, assemble, install, monitor, and maintain all instrumentation required for implementing the three subsidence monitoring systems; and (2) to evaluate performance of each instrument individually and as part of the appropriate monitoring system or systems. The use of an automatic level and a rod extensometer for measuring structure performance, and the automatic level, steel tape extensometer, FPBX, FPBI, USBM borehole deformation gauge, and vibrating wire stressmeters for measuring the performance of caving systems are recommended.

  4. 21 CFR 880.2420 - Electronic monitor for gravity flow infusion systems.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electronic monitor for gravity flow infusion... and Personal Use Monitoring Devices § 880.2420 Electronic monitor for gravity flow infusion systems. (a) Identification. An electronic monitor for gravity flow infusion systems is a device used to...

  5. 21 CFR 880.2420 - Electronic monitor for gravity flow infusion systems.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Electronic monitor for gravity flow infusion... and Personal Use Monitoring Devices § 880.2420 Electronic monitor for gravity flow infusion systems. (a) Identification. An electronic monitor for gravity flow infusion systems is a device used to...

  6. 21 CFR 880.2420 - Electronic monitor for gravity flow infusion systems.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Electronic monitor for gravity flow infusion... and Personal Use Monitoring Devices § 880.2420 Electronic monitor for gravity flow infusion systems. (a) Identification. An electronic monitor for gravity flow infusion systems is a device used to...

  7. 21 CFR 880.2420 - Electronic monitor for gravity flow infusion systems.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Electronic monitor for gravity flow infusion... and Personal Use Monitoring Devices § 880.2420 Electronic monitor for gravity flow infusion systems. (a) Identification. An electronic monitor for gravity flow infusion systems is a device used to...

  8. 21 CFR 880.2420 - Electronic monitor for gravity flow infusion systems.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Electronic monitor for gravity flow infusion... and Personal Use Monitoring Devices § 880.2420 Electronic monitor for gravity flow infusion systems. (a) Identification. An electronic monitor for gravity flow infusion systems is a device used to...

  9. 40 CFR 60.2939 - What continuous emission monitoring systems must I install?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... systems must I install? 60.2939 Section 60.2939 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... and Qualification Monitoring § 60.2939 What continuous emission monitoring systems must I install? (a) You must install, calibrate, maintain, and operate continuous emission monitoring systems for carbon...

  10. Introducing a new monitoring manual for home fortification and strengthening capacity to monitor nutrition interventions.

    PubMed

    Jefferds, Maria Elena D; Flores-Ayala, Rafael

    2015-12-01

    Lack of monitoring capacity is a key barrier for nutrition interventions and limits programme management, decision making and programme effectiveness in many low-income and middle-income countries. A 2011 global assessment reported lack of monitoring capacity was the top barrier for home fortification interventions, such as micronutrient powders or lipid-based nutrient supplements. A Manual for Developing and Implementing Monitoring Systems for Home Fortification Interventions was recently disseminated. It is comprehensive and describes monitoring concepts and frameworks and includes monitoring tools and worksheets. The monitoring manual describes the steps of developing and implementing a monitoring system for home fortification interventions, including identifying and engaging stakeholders; developing a programme description including logic model and logical framework; refining the purpose of the monitoring system, identifying users and their monitoring needs; describing the design of the monitoring system; developing indicators; describing the core components of a comprehensive monitoring plan; and considering factors related to stage of programme development, sustainability and scale up. A fictional home fortification example is used throughout the monitoring manual to illustrate these steps. The monitoring manual is a useful tool to support the development and implementation of home fortification intervention monitoring systems. In the context of systematic capacity gaps to design, implement and monitor nutrition interventions in many low-income and middle-income countries, the dissemination of new tools, such as monitoring manuals may have limited impact without additional attention to strengthening other individual, organisational and systems levels capacities. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.

  11. Towards an Ontology-Based Approach to Support Monitoring the Data of the International Monitoring System (IMS)

    NASA Astrophysics Data System (ADS)

    Laban, Shaban; El-Desouky, Ali

    2010-05-01

    The heterogeneity of the distributed processing systems, monitored data and resources is an obvious challenge in monitoring the data of International Monitoring System (IMS) of the Comprehensive Nuclear Test-Ban Treaty organization (CTBTO). Processing engineers, analysts, operators and other interested parties seek for intelligent tools and software that hide the underlying complexity of the systems, allowing them to manage the operation and monitoring the systems at a higher level, focusing on what the expected behavior and results should be instead of how to specifically achieve it. Also, it is needed to share common understanding of the structure of organization information, data, and products among staff, software agents, and policy making organs. Additionally, introducing new monitoring object or system should not complicate the overall system and should be feasible. An ontologybased approach is presented in this paper aiming to support monitoring real-time data processing and supervising the various system resources, focusing on integrating and sharing same knowledge and status information of the system among different environments. The results of a prototype framework is presented and analyzed.

  12. General Purpose Data-Driven Online System Health Monitoring with Applications to Space Operations

    NASA Technical Reports Server (NTRS)

    Iverson, David L.; Spirkovska, Lilly; Schwabacher, Mark

    2010-01-01

    Modern space transportation and ground support system designs are becoming increasingly sophisticated and complex. Determining the health state of these systems using traditional parameter limit checking, or model-based or rule-based methods is becoming more difficult as the number of sensors and component interactions grows. Data-driven monitoring techniques have been developed to address these issues by analyzing system operations data to automatically characterize normal system behavior. System health can be monitored by comparing real-time operating data with these nominal characterizations, providing detection of anomalous data signatures indicative of system faults, failures, or precursors of significant failures. The Inductive Monitoring System (IMS) is a general purpose, data-driven system health monitoring software tool that has been successfully applied to several aerospace applications and is under evaluation for anomaly detection in vehicle and ground equipment for next generation launch systems. After an introduction to IMS application development, we discuss these NASA online monitoring applications, including the integration of IMS with complementary model-based and rule-based methods. Although the examples presented in this paper are from space operations applications, IMS is a general-purpose health-monitoring tool that is also applicable to power generation and transmission system monitoring.

  13. An Internet of Things based physiological signal monitoring and receiving system for virtual enhanced health care network.

    PubMed

    Rajan, J Pandia; Rajan, S Edward

    2018-01-01

    Wireless physiological signal monitoring system designing with secured data communication in the health care system is an important and dynamic process. We propose a signal monitoring system using NI myRIO connected with the wireless body sensor network through multi-channel signal acquisition method. Based on the server side validation of the signal, the data connected to the local server is updated in the cloud. The Internet of Things (IoT) architecture is used to get the mobility and fast access of patient data to healthcare service providers. This research work proposes a novel architecture for wireless physiological signal monitoring system using ubiquitous healthcare services by virtual Internet of Things. We showed an improvement in method of access and real time dynamic monitoring of physiological signal of this remote monitoring system using virtual Internet of thing approach. This remote monitoring and access system is evaluated in conventional value. This proposed system is envisioned to modern smart health care system by high utility and user friendly in clinical applications. We claim that the proposed scheme significantly improves the accuracy of the remote monitoring system compared to the other wireless communication methods in clinical system.

  14. 21 CFR 876.1725 - Gastrointestinal motility monitoring system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Gastrointestinal motility monitoring system. 876... Gastrointestinal motility monitoring system. (a) Identification. A gastrointestinal motility monitoring system is a device used to measure peristalic activity or pressure in the stomach or esophagus by means of a probe...

  15. 40 CFR 60.1730 - How do I make sure my continuous emission monitoring systems are operating correctly?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... emission monitoring systems are operating correctly? 60.1730 Section 60.1730 Protection of Environment... continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or carbon dioxide...

  16. 40 CFR 60.1730 - How do I make sure my continuous emission monitoring systems are operating correctly?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... emission monitoring systems are operating correctly? 60.1730 Section 60.1730 Protection of Environment... continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or carbon dioxide...

  17. 40 CFR 62.15185 - How do I make sure my continuous emission monitoring systems are operating correctly?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... emission monitoring systems are operating correctly? 62.15185 Section 62.15185 Protection of Environment... make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or...

  18. 40 CFR 60.2940 - How do I make sure my continuous emission monitoring systems are operating correctly?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... emission monitoring systems are operating correctly? 60.2940 Section 60.2940 Protection of Environment... monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure carbon monoxide and oxygen. (b) Complete your...

  19. 40 CFR 60.3039 - How do I make sure my continuous emission monitoring systems are operating correctly?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... emission monitoring systems are operating correctly? 60.3039 Section 60.3039 Protection of Environment... emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure carbon monoxide and oxygen. (b...

  20. 40 CFR 60.1730 - How do I make sure my continuous emission monitoring systems are operating correctly?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... emission monitoring systems are operating correctly? 60.1730 Section 60.1730 Protection of Environment... continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or carbon dioxide...

  1. 40 CFR 60.2940 - How do I make sure my continuous emission monitoring systems are operating correctly?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... emission monitoring systems are operating correctly? 60.2940 Section 60.2940 Protection of Environment... monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure carbon monoxide and oxygen. (b) Complete your...

  2. 40 CFR 60.2940 - How do I make sure my continuous emission monitoring systems are operating correctly?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... emission monitoring systems are operating correctly? 60.2940 Section 60.2940 Protection of Environment... monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure carbon monoxide and oxygen. (b) Complete your...

  3. 40 CFR 60.1730 - How do I make sure my continuous emission monitoring systems are operating correctly?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... emission monitoring systems are operating correctly? 60.1730 Section 60.1730 Protection of Environment... continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or carbon dioxide...

  4. 40 CFR 60.3039 - How do I make sure my continuous emission monitoring systems are operating correctly?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... emission monitoring systems are operating correctly? 60.3039 Section 60.3039 Protection of Environment... emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure carbon monoxide and oxygen. (b...

  5. 40 CFR 62.15185 - How do I make sure my continuous emission monitoring systems are operating correctly?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... emission monitoring systems are operating correctly? 62.15185 Section 62.15185 Protection of Environment... make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or...

  6. 40 CFR 60.3039 - How do I make sure my continuous emission monitoring systems are operating correctly?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... emission monitoring systems are operating correctly? 60.3039 Section 60.3039 Protection of Environment... emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure carbon monoxide and oxygen. (b...

  7. 40 CFR 60.3039 - How do I make sure my continuous emission monitoring systems are operating correctly?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... emission monitoring systems are operating correctly? 60.3039 Section 60.3039 Protection of Environment... emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure carbon monoxide and oxygen. (b...

  8. 40 CFR 60.1730 - How do I make sure my continuous emission monitoring systems are operating correctly?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... emission monitoring systems are operating correctly? 60.1730 Section 60.1730 Protection of Environment... continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or carbon dioxide...

  9. 40 CFR 62.15185 - How do I make sure my continuous emission monitoring systems are operating correctly?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... emission monitoring systems are operating correctly? 62.15185 Section 62.15185 Protection of Environment... make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or...

  10. 40 CFR 60.3039 - How do I make sure my continuous emission monitoring systems are operating correctly?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... emission monitoring systems are operating correctly? 60.3039 Section 60.3039 Protection of Environment... emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure carbon monoxide and oxygen. (b...

  11. 40 CFR 62.15185 - How do I make sure my continuous emission monitoring systems are operating correctly?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... emission monitoring systems are operating correctly? 62.15185 Section 62.15185 Protection of Environment... make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or...

  12. 40 CFR 62.15185 - How do I make sure my continuous emission monitoring systems are operating correctly?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... emission monitoring systems are operating correctly? 62.15185 Section 62.15185 Protection of Environment... make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or...

  13. 50 CFR 665.19 - Vessel monitoring system.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 50 Wildlife and Fisheries 13 2012-10-01 2012-10-01 false Vessel monitoring system. 665.19 Section... monitoring system. (a) Applicability. The holder of any of the following permits is subject to the vessel monitoring system requirements in this part: (1) Hawaii longline limited access permit issued pursuant to...

  14. 50 CFR 665.19 - Vessel monitoring system.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 50 Wildlife and Fisheries 13 2013-10-01 2013-10-01 false Vessel monitoring system. 665.19 Section... monitoring system. (a) Applicability. The holder of any of the following permits is subject to the vessel monitoring system requirements in this part: (1) Hawaii longline limited access permit issued pursuant to...

  15. 50 CFR 665.19 - Vessel monitoring system.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 50 Wildlife and Fisheries 11 2011-10-01 2011-10-01 false Vessel monitoring system. 665.19 Section... monitoring system. (a) Applicability. The holder of any of the following permits is subject to the vessel monitoring system requirements in this part: (1) Hawaii longline limited access permit issued pursuant to...

  16. 40 CFR 60.1740 - What is my schedule for evaluating continuous emission monitoring systems?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... continuous emission monitoring systems? 60.1740 Section 60.1740 Protection of Environment ENVIRONMENTAL... evaluating continuous emission monitoring systems? (a) Conduct annual evaluations of your continuous emission monitoring systems no more than 13 months after the previous evaluation was conducted. (b) Evaluate your...

  17. 49 CFR 385.715 - Duration of safety monitoring system.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 5 2011-10-01 2011-10-01 false Duration of safety monitoring system. 385.715... SAFETY FITNESS PROCEDURES Safety Monitoring System for Non-North American Carriers § 385.715 Duration of safety monitoring system. (a) Each non-North America-domiciled carrier subject to this subpart will...

  18. 50 CFR 665.19 - Vessel monitoring system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 50 Wildlife and Fisheries 9 2010-10-01 2010-10-01 false Vessel monitoring system. 665.19 Section... monitoring system. (a) Applicability. The holder of any of the following permits is subject to the vessel monitoring system requirements in this part: (1) Hawaii longline limited access permit issued pursuant to...

  19. 49 CFR 385.117 - Duration of safety monitoring system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Duration of safety monitoring system. 385.117... SAFETY FITNESS PROCEDURES Safety Monitoring System for Mexico-Domiciled Carriers § 385.117 Duration of safety monitoring system. (a) Each Mexico-domiciled carrier subject to this subpart will remain in the...

  20. 49 CFR 385.117 - Duration of safety monitoring system.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 5 2011-10-01 2011-10-01 false Duration of safety monitoring system. 385.117... SAFETY FITNESS PROCEDURES Safety Monitoring System for Mexico-Domiciled Carriers § 385.117 Duration of safety monitoring system. (a) Each Mexico-domiciled carrier subject to this subpart will remain in the...

  1. 40 CFR 62.15195 - What is my schedule for evaluating continuous emission monitoring systems?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... continuous emission monitoring systems? 62.15195 Section 62.15195 Protection of Environment ENVIRONMENTAL... evaluating continuous emission monitoring systems? (a) Conduct annual evaluations of your continuous emission monitoring systems no more than 13 months after the previous evaluation was conducted. (b) Evaluate your...

  2. 49 CFR 385.715 - Duration of safety monitoring system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Duration of safety monitoring system. 385.715... SAFETY FITNESS PROCEDURES Safety Monitoring System for Non-North American Carriers § 385.715 Duration of safety monitoring system. (a) Each non-North America-domiciled carrier subject to this subpart will...

  3. 40 CFR 62.15195 - What is my schedule for evaluating continuous emission monitoring systems?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... continuous emission monitoring systems? 62.15195 Section 62.15195 Protection of Environment ENVIRONMENTAL... evaluating continuous emission monitoring systems? (a) Conduct annual evaluations of your continuous emission monitoring systems no more than 13 months after the previous evaluation was conducted. (b) Evaluate your...

  4. 78 FR 58286 - Proposed Information Collection; Comment Request; Western Region Vessel Monitoring System and Pre...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-23

    ... Collection; Comment Request; Western Region Vessel Monitoring System and Pre-Trip Reporting Requirements... information or new problems in the fisheries. Vessel Monitoring System (VMS) units will facilitate enforcement... monitoring system (VMS) activation reports, 15 minutes; pre-trip reports, 5 minutes. Estimated Burden Hours...

  5. Evaluation of the Monitor-CTA Automatic Vehicle Monitoring System

    DOT National Transportation Integrated Search

    1974-03-01

    In June 1972 the Urban Mass Transportation Administration requested that the Transportation System Center of DOT perform an evaluation of the CTA (Chicago Transit Authority) Monitor-Automatic Vehicle Monitor (AVM) system. TSC planned the overall eval...

  6. Automated monitoring of recovered water quality

    NASA Technical Reports Server (NTRS)

    Misselhorn, J. E.; Hartung, W. H.; Witz, S. W.

    1974-01-01

    Laboratory prototype water quality monitoring system provides automatic system for online monitoring of chemical, physical, and bacteriological properties of recovered water and for signaling malfunction in water recovery system. Monitor incorporates whenever possible commercially available sensors suitably modified.

  7. [Implementation of Oncomelania hupensis monitoring system based on Baidu Map].

    PubMed

    Zhi-Hua, Chen; Yi-Sheng, Zhu; Zhi-Qiang, Xue; Xue-Bing, Li; Yi-Min, Ding; Li-Jun, Bi; Kai-Min, Gao; You, Zhang

    2017-10-25

    To construct the Oncomelania hupensis snail monitoring system based on the Baidu Map. The environmental basic information about historical snail environment and existing snail environment, etc. was collected with the monitoring data about different kinds of O. hupensis snails, and then the O. hupensis snail monitoring system was built. Geographic Information System (GIS) and the electronic fence technology and Application Program Interface (API) were applied to set up the electronic fence of the snail surveillance environments, and the electronic fence was connected to the database of the snail surveillance. The O. hupensis snail monitoring system based on the Baidu Map were built up, including three modules of O. hupensis Snail Monitoring Environmental Database, Dynamic Monitoring Platform and Electronic Map. The information about monitoring O. hupensis snails could be obtained through the computer and smartphone simultaneously. The O. hupensis snail monitoring system, which is based on Baidu Map, is a visible platform to follow the process of snailsearching and molluscaciding.

  8. Space shuttle propulsion systems on-board checkout and monitoring system development study

    NASA Technical Reports Server (NTRS)

    1971-01-01

    Investigations on the fundamental space shuttle propulsion systems program are reported, with emphasis on in-depth reviews of preliminary drafts of the guidelines. The guidelines will be used to incorporate the onboard checkout and monitoring function into the basic design of the propulsion systems and associated interfacing systems. The analysis of checkout and monitoring requirements of the Titan 3 L expandable booster propulsion systems was completed, and the techniques for accomplishing the checkout and monitoring functions were determined. Updating results of the basic study of propulsion system checkout and monitoring is continuing.

  9. Design of a Water Environment Monitoring System Based on Wireless Sensor Networks

    PubMed Central

    Jiang, Peng; Xia, Hongbo; He, Zhiye; Wang, Zheming

    2009-01-01

    A water environmental monitoring system based on a wireless sensor network is proposed. It consists of three parts: data monitoring nodes, data base station and remote monitoring center. This system is suitable for the complex and large-scale water environment monitoring, such as for reservoirs, lakes, rivers, swamps, and shallow or deep groundwaters. This paper is devoted to the explanation and illustration for our new water environment monitoring system design. The system had successfully accomplished the online auto-monitoring of the water temperature and pH value environment of an artificial lake. The system's measurement capacity ranges from 0 to 80 °C for water temperature, with an accuracy of ±0.5 °C; from 0 to 14 on pH value, with an accuracy of ±0.05 pH units. Sensors applicable to different water quality scenarios should be installed at the nodes to meet the monitoring demands for a variety of water environments and to obtain different parameters. The monitoring system thus promises broad applicability prospects. PMID:22454592

  10. 40 CFR 75.24 - Out-of-control periods and adjustment for system bias.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... subsequent tests: (1) Apply the procedures for missing data substitution to emissions from affected unit(s... monitor or continuous emission monitoring system is out-of-control, any data recorded by the monitor or monitoring system are not quality-assured and shall not be used in calculating monitor data availabilities...

  11. 40 CFR 75.24 - Out-of-control periods and adjustment for system bias.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... subsequent tests: (1) Apply the procedures for missing data substitution to emissions from affected unit(s... monitor or continuous emission monitoring system is out-of-control, any data recorded by the monitor or monitoring system are not quality-assured and shall not be used in calculating monitor data availabilities...

  12. 40 CFR 75.24 - Out-of-control periods and adjustment for system bias.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... subsequent tests: (1) Apply the procedures for missing data substitution to emissions from affected unit(s... monitor or continuous emission monitoring system is out-of-control, any data recorded by the monitor or monitoring system are not quality-assured and shall not be used in calculating monitor data availabilities...

  13. 40 CFR 75.24 - Out-of-control periods and adjustment for system bias.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... subsequent tests: (1) Apply the procedures for missing data substitution to emissions from affected unit(s... monitor or continuous emission monitoring system is out-of-control, any data recorded by the monitor or monitoring system are not quality-assured and shall not be used in calculating monitor data availabilities...

  14. 40 CFR 62.15180 - How are the data from the continuous emission monitoring systems used?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... emission monitoring systems used? 62.15180 Section 62.15180 Protection of Environment ENVIRONMENTAL... Constructed on or Before August 30, 1999 Continuous Emission Monitoring § 62.15180 How are the data from the continuous emission monitoring systems used? You must use data from the continuous emission monitoring...

  15. 40 CFR 62.15205 - What minimum amount of monitoring data must I collect with my continuous emission monitoring...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... must I collect with my continuous emission monitoring systems and is this requirement enforceable? 62... with my continuous emission monitoring systems and is this requirement enforceable? (a) Where continuous emission monitoring systems are required, obtain 1-hour arithmetic averages. Make sure the...

  16. 40 CFR 62.15205 - What minimum amount of monitoring data must I collect with my continuous emission monitoring...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... must I collect with my continuous emission monitoring systems and is this requirement enforceable? 62... with my continuous emission monitoring systems and is this requirement enforceable? (a) Where continuous emission monitoring systems are required, obtain 1-hour arithmetic averages. Make sure the...

  17. 40 CFR 60.1725 - How are the data from the continuous emission monitoring systems used?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... emission monitoring systems used? 60.1725 Section 60.1725 Protection of Environment ENVIRONMENTAL... Before August 30, 1999 Model Rule-Continuous Emission Monitoring § 60.1725 How are the data from the continuous emission monitoring systems used? You must use data from the continuous emission monitoring...

  18. 40 CFR 60.2942 - What is the minimum amount of monitoring data I must collect with my continuous emission...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... monitoring data I must collect with my continuous emission monitoring systems, and is the data collection... with my continuous emission monitoring systems, and is the data collection requirement enforceable? (a) Where continuous emission monitoring systems are required, obtain 1-hour arithmetic averages. Make sure...

  19. 40 CFR 60.1275 - What additional requirements must I meet for the operation of my continuous emission monitoring...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... meet for the operation of my continuous emission monitoring systems and continuous opacity monitoring... additional requirements must I meet for the operation of my continuous emission monitoring systems and continuous opacity monitoring system? Use the required span values and applicable performance specifications...

  20. 40 CFR 60.3041 - What is the minimum amount of monitoring data I must collect with my continuous emission...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... monitoring data I must collect with my continuous emission monitoring systems, and is the data collection... collect with my continuous emission monitoring systems, and is the data collection requirement enforceable? (a) Where continuous emission monitoring systems are required, obtain 1-hour arithmetic averages...

  1. 40 CFR 60.3041 - What is the minimum amount of monitoring data I must collect with my continuous emission...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... monitoring data I must collect with my continuous emission monitoring systems, and is the data collection... collect with my continuous emission monitoring systems, and is the data collection requirement enforceable? (a) Where continuous emission monitoring systems are required, obtain 1-hour arithmetic averages...

  2. 40 CFR 62.15280 - What minimum amount of monitoring data must I collect with my continuous parameter monitoring...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... must I collect with my continuous parameter monitoring systems and is this requirement enforceable? 62... with my continuous parameter monitoring systems and is this requirement enforceable? (a) Where continuous parameter monitoring systems are used, obtain 1-hour arithmetic averages for three parameters: (1...

  3. 40 CFR 60.1275 - What additional requirements must I meet for the operation of my continuous emission monitoring...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... meet for the operation of my continuous emission monitoring systems and continuous opacity monitoring... additional requirements must I meet for the operation of my continuous emission monitoring systems and continuous opacity monitoring system? Use the required span values and applicable performance specifications...

  4. 40 CFR 62.15280 - What minimum amount of monitoring data must I collect with my continuous parameter monitoring...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... must I collect with my continuous parameter monitoring systems and is this requirement enforceable? 62... with my continuous parameter monitoring systems and is this requirement enforceable? (a) Where continuous parameter monitoring systems are used, obtain 1-hour arithmetic averages for three parameters: (1...

  5. 40 CFR 60.1335 - What is the minimum amount of monitoring data I must collect with my continuous parameter...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... monitoring data I must collect with my continuous parameter monitoring systems and is the data collection... parameter monitoring systems and is the data collection requirement enforceable? (a) Where continuous parameter monitoring systems are used, obtain 1-hour arithmetic averages for three parameters: (1) Load...

  6. 40 CFR 62.15180 - How are the data from the continuous emission monitoring systems used?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... emission monitoring systems used? 62.15180 Section 62.15180 Protection of Environment ENVIRONMENTAL... Constructed on or Before August 30, 1999 Continuous Emission Monitoring § 62.15180 How are the data from the continuous emission monitoring systems used? You must use data from the continuous emission monitoring...

  7. 40 CFR 60.1335 - What is the minimum amount of monitoring data I must collect with my continuous parameter...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... monitoring data I must collect with my continuous parameter monitoring systems and is the data collection... parameter monitoring systems and is the data collection requirement enforceable? (a) Where continuous parameter monitoring systems are used, obtain 1-hour arithmetic averages for three parameters: (1) Load...

  8. 40 CFR 60.2942 - What is the minimum amount of monitoring data I must collect with my continuous emission...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... monitoring data I must collect with my continuous emission monitoring systems, and is the data collection... with my continuous emission monitoring systems, and is the data collection requirement enforceable? (a) Where continuous emission monitoring systems are required, obtain 1-hour arithmetic averages. Make sure...

  9. 40 CFR 60.1725 - How are the data from the continuous emission monitoring systems used?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... emission monitoring systems used? 60.1725 Section 60.1725 Protection of Environment ENVIRONMENTAL... Before August 30, 1999 Model Rule-Continuous Emission Monitoring § 60.1725 How are the data from the continuous emission monitoring systems used? You must use data from the continuous emission monitoring...

  10. NASA JSC water monitor system: City of Houston field demonstration

    NASA Technical Reports Server (NTRS)

    Taylor, R. E.; Jeffers, E. L.; Fricks, D. H.

    1979-01-01

    A water quality monitoring system with on-line and real time operation similar to the function in a spacecraft was investigated. A system with the capability to determine conformance to future high effluent quality standards and to increase the potential for reclamation and reuse of water was designed. Although all system capabilities were not verified in the initial field trial, fully automated operation over a sustained period with only routine manual adjustments was accomplished. Two major points were demonstrated: (1) the water monitor system has great potential in water monitoring and/or process control applications; and (2) the water monitor system represents a vast improvement over conventional (grab sample) water monitoring techniques.

  11. Monitoring industrial facilities using principles of integration of fiber classifier and local sensor networks

    NASA Astrophysics Data System (ADS)

    Korotaev, Valery V.; Denisov, Victor M.; Rodrigues, Joel J. P. C.; Serikova, Mariya G.; Timofeev, Andrey V.

    2015-05-01

    The paper deals with the creation of integrated monitoring systems. They combine fiber-optic classifiers and local sensor networks. These systems allow for the monitoring of complex industrial objects. Together with adjacent natural objects, they form the so-called geotechnical systems. An integrated monitoring system may include one or more spatially continuous fiber-optic classifiers based on optic fiber and one or more arrays of discrete measurement sensors, which are usually combined in sensor networks. Fiber-optic classifiers are already widely used for the control of hazardous extended objects (oil and gas pipelines, railways, high-rise buildings, etc.). To monitor local objects, discrete measurement sensors are generally used (temperature, pressure, inclinometers, strain gauges, accelerometers, sensors measuring the composition of impurities in the air, and many others). However, monitoring complex geotechnical systems require a simultaneous use of continuous spatially distributed sensors based on fiber-optic cable and connected local discrete sensors networks. In fact, we are talking about integration of the two monitoring methods. This combination provides an additional way to create intelligent monitoring systems. Modes of operation of intelligent systems can automatically adapt to changing environmental conditions. For this purpose, context data received from one sensor (e.g., optical channel) may be used to change modes of work of other sensors within the same monitoring system. This work also presents experimental results of the prototype of the integrated monitoring system.

  12. Implementation of Multiple Host Nodes in Wireless Sensing Node Network System for Landslide Monitoring

    NASA Astrophysics Data System (ADS)

    Abas, Faizulsalihin bin; Takayama, Shigeru

    2015-02-01

    This paper proposes multiple host nodes in Wireless Sensing Node Network System (WSNNS) for landslide monitoring. As landslide disasters damage monitoring system easily, one major demand in landslide monitoring is the flexibility and robustness of the system to evaluate the current situation in the monitored area. For various reasons WSNNS can provide an important contribution to reach that aim. In this system, acceleration sensors and GPS are deployed in sensing nodes. Location information by GPS, enable the system to estimate network topology and enable the system to perceive the location in emergency by monitoring the node mode. Acceleration sensors deployment, capacitate this system to detect slow mass movement that can lead to landslide occurrence. Once deployed, sensing nodes self-organize into an autonomous wireless ad hoc network. The measurement parameter data from sensing nodes is transmitted to Host System via host node and "Cloud" System. The implementation of multiple host nodes in Local Sensing Node Network System (LSNNS), improve risk- management of the WSNNS for real-time monitoring of landslide disaster.

  13. Inductive monitoring system constructed from nominal system data and its use in real-time system monitoring

    NASA Technical Reports Server (NTRS)

    Iverson, David L. (Inventor)

    2008-01-01

    The present invention relates to an Inductive Monitoring System (IMS), its software implementations, hardware embodiments and applications. Training data is received, typically nominal system data acquired from sensors in normally operating systems or from detailed system simulations. The training data is formed into vectors that are used to generate a knowledge database having clusters of nominal operating regions therein. IMS monitors a system's performance or health by comparing cluster parameters in the knowledge database with incoming sensor data from a monitored-system formed into vectors. Nominal performance is concluded when a monitored-system vector is determined to lie within a nominal operating region cluster or lies sufficiently close to a such a cluster as determined by a threshold value and a distance metric. Some embodiments of IMS include cluster indexing and retrieval methods that increase the execution speed of IMS.

  14. 40 CFR Table 4 to Subpart Hhhhhhh... - Applicability of the General Provisions to Part 63

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... SSM plan for continuous monitoring systems No. § 63.8(c)(5) Continuous opacity monitoring system...) Written procedures for continuous monitoring systems Yes, except for last sentence, which refers to an SSM plan. SSM plans are not required § 63.8(e) Continuous monitoring systems performance evaluation Yes...

  15. A precipitation collector and automated pH-monitoring system

    Treesearch

    Gerald M. Aubertin; Benjamin C. Thorner; John Campbell

    1976-01-01

    A sensitive precipitation collector and automated pH-monitoring system are described. This system provides for continuous monitoring and recording of the pH of precipitation. Discrete or composite rainwater samples are manually obtainable for chemical analyses. The system can easily be adapted to accommodate a flow-through specific conductance probe and monitoring...

  16. 40 CFR Table 3 of Subpart Aaaa to... - Requirements for Validating Continuous Emission Monitoring Systems (CEMS)

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Requirements for Validating Continuous Emission Monitoring Systems (CEMS) 3 Table 3 of Subpart AAAA to Part 60 Protection of Environment... Continuous Emission Monitoring Systems (CEMS) For the following continuous emission monitoring systems Use...

  17. 40 CFR Table 3 of Subpart Aaaa to... - Requirements for Validating Continuous Emission Monitoring Systems (CEMS)

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Requirements for Validating Continuous Emission Monitoring Systems (CEMS) 3 Table 3 of Subpart AAAA to Part 60 Protection of Environment... Continuous Emission Monitoring Systems (CEMS) For the following continuous emission monitoring systems Use...

  18. Improved Real-Time Monitoring Using Multiple Expert Systems

    NASA Technical Reports Server (NTRS)

    Schwuttke, Ursula M.; Angelino, Robert; Quan, Alan G.; Veregge, John; Childs, Cynthia

    1993-01-01

    Monitor/Analyzer of Real-Time Voyager Engineering Link (MARVEL) computer program implements combination of techniques of both conventional automation and artificial intelligence to improve monitoring of complicated engineering system. Designed to support ground-based operations of Voyager spacecraft, also adapted to other systems. Enables more-accurate monitoring and analysis of telemetry, enhances productivity of monitoring personnel, reduces required number of such personnel by performing routine monitoring tasks, and helps ensure consistency in face of turnover of personnel. Programmed in C language and includes commercial expert-system software shell also written in C.

  19. Microfabricated Hydrogen Sensor Technology for Aerospace and Commercial Applications

    NASA Technical Reports Server (NTRS)

    Hunter, Gary W.; Bickford, R. L.; Jansa, E. D.; Makel, D. B.; Liu, C. C.; Wu, Q. H.; Powers, W. T.

    1994-01-01

    Leaks on the Space Shuttle while on the Launch Pad have generated interest in hydrogen leak monitoring technology. An effective leak monitoring system requires reliable hydrogen sensors, hardware, and software to monitor the sensors. The system should process the sensor outputs and provide real-time leak monitoring information to the operator. This paper discusses the progress in developing such a complete leak monitoring system. Advanced microfabricated hydrogen sensors are being fabricated at Case Western Reserve University (CWRU) and tested at NASA Lewis Research Center (LeRC) and Gencorp Aerojet (Aerojet). Changes in the hydrogen concentrations are detected using a PdAg on silicon Schottky diode structure. Sensor temperature control is achieved with a temperature sensor and heater fabricated onto the sensor chip. Results of the characterization of these sensors are presented. These sensors can detect low concentrations of hydrogen in inert environments with high sensitivity and quick response time. Aerojet is developing the hardware and software for a multipoint leak monitoring system designed to provide leak source and magnitude information in real time. The monitoring system processes data from the hydrogen sensors and presents the operator with a visual indication of the leak location and magnitude. Work has commenced on integrating the NASA LeRC-CWRU hydrogen sensors with the Aerojet designed monitoring system. Although the leak monitoring system was designed for hydrogen propulsion systems, the possible applications of this monitoring system are wide ranged. Possible commercialization of the system will also be discussed.

  20. Water monitor system: Phase 1 test report

    NASA Technical Reports Server (NTRS)

    Taylor, R. E.; Jeffers, E. L.

    1976-01-01

    Automatic water monitor system was tested with the objectives of assuring high-quality effluent standards and accelerating the practice of reclamation and reuse of water. The NASA water monitor system is described. Various components of the system, including the necessary sensors, the sample collection system, and the data acquisition and display system, are discussed. The test facility and the analysis methods are described. Test results are reviewed, and recommendations for water monitor system design improvement are presented.

  1. Coordinated Monitoring Systems for Early Care and Education. OPRE Research Brief 2016-19

    ERIC Educational Resources Information Center

    Maxwell, Kelly; Sosinsky, Laura; Tout, Kathryn; Hegseth, Danielle

    2016-01-01

    Early care and education providers are subject to monitoring by multiple agencies and organizations. In this brief provides an overview of monitoring and the major early care and education monitoring systems. It then offers possible goals for a coordinated monitoring system and describes some approaches to addressing those goals. Eleven dimensions…

  2. 40 CFR 60.1230 - What continuous emission monitoring systems must I install for gaseous pollutants?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... according to the “Monitoring Requirements” in § 60.13. (c) You must monitor the oxygen (or carbon dioxide... systems must I install for gaseous pollutants? 60.1230 Section 60.1230 Protection of Environment... Continuous Emission Monitoring § 60.1230 What continuous emission monitoring systems must I install for...

  3. 40 CFR 60.1230 - What continuous emission monitoring systems must I install for gaseous pollutants?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... according to the “Monitoring Requirements” in § 60.13. (c) You must monitor the oxygen (or carbon dioxide... systems must I install for gaseous pollutants? 60.1230 Section 60.1230 Protection of Environment... Continuous Emission Monitoring § 60.1230 What continuous emission monitoring systems must I install for...

  4. 40 CFR 60.1230 - What continuous emission monitoring systems must I install for gaseous pollutants?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... according to the “Monitoring Requirements” in § 60.13. (c) You must monitor the oxygen (or carbon dioxide... systems must I install for gaseous pollutants? 60.1230 Section 60.1230 Protection of Environment... Continuous Emission Monitoring § 60.1230 What continuous emission monitoring systems must I install for...

  5. 40 CFR 60.1825 - What is the minimum amount of monitoring data I must collect with my continuous parameter...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... monitoring data I must collect with my continuous parameter monitoring systems and is the data collection... must collect with my continuous parameter monitoring systems and is the data collection requirement enforceable? (a) Where continuous parameter monitoring systems are used, obtain 1-hour arithmetic averages for...

  6. 40 CFR 60.1750 - What is the minimum amount of monitoring data I must collect with my continuous emission...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... monitoring data I must collect with my continuous emission monitoring systems and is the data collection... I must collect with my continuous emission monitoring systems and is the data collection requirement enforceable? (a) Where continuous emission monitoring systems are required, obtain 1-hour arithmetic averages...

  7. 40 CFR 60.1825 - What is the minimum amount of monitoring data I must collect with my continuous parameter...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... monitoring data I must collect with my continuous parameter monitoring systems and is the data collection... must collect with my continuous parameter monitoring systems and is the data collection requirement enforceable? (a) Where continuous parameter monitoring systems are used, obtain 1-hour arithmetic averages for...

  8. 40 CFR 60.1260 - What is the minimum amount of monitoring data I must collect with my continuous emission...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... monitoring data I must collect with my continuous emission monitoring systems and is the data collection... monitoring systems and is the data collection requirement enforceable? (a) Where continuous emission monitoring systems are required, obtain 1-hour arithmetic averages. Make sure the averages for sulfur dioxide...

  9. 40 CFR 60.1260 - What is the minimum amount of monitoring data I must collect with my continuous emission...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... monitoring data I must collect with my continuous emission monitoring systems and is the data collection... monitoring systems and is the data collection requirement enforceable? (a) Where continuous emission monitoring systems are required, obtain 1-hour arithmetic averages. Make sure the averages for sulfur dioxide...

  10. 40 CFR 60.1750 - What is the minimum amount of monitoring data I must collect with my continuous emission...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... monitoring data I must collect with my continuous emission monitoring systems and is the data collection... I must collect with my continuous emission monitoring systems and is the data collection requirement enforceable? (a) Where continuous emission monitoring systems are required, obtain 1-hour arithmetic averages...

  11. Application research of Ganglia in Hadoop monitoring and management

    NASA Astrophysics Data System (ADS)

    Li, Gang; Ding, Jing; Zhou, Lixia; Yang, Yi; Liu, Lei; Wang, Xiaolei

    2017-03-01

    There are many applications of Hadoop System in the field of large data, cloud computing. The test bench of storage and application in seismic network at Earthquake Administration of Tianjin use with Hadoop system, which is used the open source software of Ganglia to operate and monitor. This paper reviews the function, installation and configuration process, application effect of operating and monitoring in Hadoop system of the Ganglia system. It briefly introduces the idea and effect of Nagios software monitoring Hadoop system. It is valuable for the industry in the monitoring system of cloud computing platform.

  12. Inductive System Health Monitoring

    NASA Technical Reports Server (NTRS)

    Iverson, David L.

    2004-01-01

    The Inductive Monitoring System (IMS) software was developed to provide a technique to automatically produce health monitoring knowledge bases for systems that are either difficult to model (simulate) with a computer or which require computer models that are too complex to use for real time monitoring. IMS uses nominal data sets collected either directly from the system or from simulations to build a knowledge base that can be used to detect anomalous behavior in the system. Machine learning and data mining techniques are used to characterize typical system behavior by extracting general classes of nominal data from archived data sets. IMS is able to monitor the system by comparing real time operational data with these classes. We present a description of learning and monitoring method used by IMS and summarize some recent IMS results.

  13. Development of monitoring and control system for a mine main fan based on frequency converter

    NASA Astrophysics Data System (ADS)

    Zhang, Y. C.; Zhang, R. W.; Kong, X. Z.; Y Gong, J.; Chen, Q. G.

    2013-12-01

    In the process of mine exploitation, the requirement of air flow rate often changes. The procedure of traditional control mode of the fan is complex and it is hard to meet the worksite requirement for air. This system is based on Principal Computer (PC) monitoring system and high performance PLC control system. In this system, the frequency converter is adapted to adjust the fan speed and the air of worksite can be regulated steplessly. The function of the monitoring and control system contains on-line monitoring and centralized control. The system can monitor the parameters of fan in real-time, control the operation of frequency converter, as well as, control the fan and its accessory equipments. At the same time, the automation level of the system is highly, the field equipments can be monitored and controlled automatically. So, the system is an important safeguard for mine production.

  14. Engine health monitoring systems: Tools for improved maintenance management in the 1980's

    NASA Technical Reports Server (NTRS)

    Kimball, J. C.

    1981-01-01

    The performance monitoring aspect of maintenance, characteristic of the engine health monitoring system are discussed. An overview of the system activities is presented and a summary of programs for improved monitoring in the 1980's are discussed.

  15. Acoustic Techniques for Structural Health Monitoring

    NASA Astrophysics Data System (ADS)

    Frankenstein, B.; Augustin, J.; Hentschel, D.; Schubert, F.; Köhler, B.; Meyendorf, N.

    2008-02-01

    Future safety and maintenance strategies for industrial components and vehicles are based on combinations of monitoring systems that are permanently attached to or embedded in the structure, and periodic inspections. The latter belongs to conventional nondestructive evaluation (NDE) and can be enhanced or partially replaced by structural health monitoring systems. However, the main benefit of this technology for the future will consist of systems that can be differently designed based on improved safety philosophies, including continuous monitoring. This approach will increase the efficiency of inspection procedures at reduced inspection times. The Fraunhofer IZFP Dresden Branch has developed network nodes, miniaturized transmitter and receiver systems for active and passive acoustical techniques and sensor systems that can be attached to or embedded into components or structures. These systems have been used to demonstrate intelligent sensor networks for the monitoring of aerospace structures, railway systems, wind energy generators, piping system and other components. Material discontinuities and flaws have been detected and monitored during full scale fatigue testing. This paper will discuss opportunities and future trends in nondestructive evaluation and health monitoring based on new sensor principles and advanced microelectronics. It will outline various application examples of monitoring systems based on acoustic techniques and will indicate further needs for research and development.

  16. Integrated System of Structural Health Monitoring and Intelligent Management for a Cable-Stayed Bridge

    PubMed Central

    Chen, Bin; Wang, Xu; Sun, Dezhang; Xie, Xu

    2014-01-01

    It is essential to construct structural health monitoring systems for large important bridges. Zhijiang Bridge is a cable-stayed bridge that was built recently over the Hangzhou Qiantang River (the largest river in Zhejiang Province). The length of Zhijiang Bridge is 478 m, which comprises an arched twin-tower space and a twin-cable plane structure. As an example, the present study describes the integrated system of structural health monitoring and intelligent management for Zhijiang Bridge, which comprises an information acquisition system, data management system, evaluation and decision-making system, and application service system. The monitoring components include the working environment of the bridge and various factors that affect bridge safety, such as the stress and strain of the main bridge structure, vibration, cable force, temperature, and wind speed. In addition, the integrated system includes a forecasting and decision-making module for real-time online evaluation, which provides warnings and makes decisions based on the monitoring information. From this, the monitoring information, evaluation results, maintenance decisions, and warning information can be input simultaneously into the bridge monitoring center and traffic emergency center to share the monitoring data, thereby facilitating evaluations and decision making using the system. PMID:25140342

  17. Integrated system of structural health monitoring and intelligent management for a cable-stayed bridge.

    PubMed

    Chen, Bin; Wang, Xu; Sun, Dezhang; Xie, Xu

    2014-01-01

    It is essential to construct structural health monitoring systems for large important bridges. Zhijiang Bridge is a cable-stayed bridge that was built recently over the Hangzhou Qiantang River (the largest river in Zhejiang Province). The length of Zhijiang Bridge is 478 m, which comprises an arched twin-tower space and a twin-cable plane structure. As an example, the present study describes the integrated system of structural health monitoring and intelligent management for Zhijiang Bridge, which comprises an information acquisition system, data management system, evaluation and decision-making system, and application service system. The monitoring components include the working environment of the bridge and various factors that affect bridge safety, such as the stress and strain of the main bridge structure, vibration, cable force, temperature, and wind speed. In addition, the integrated system includes a forecasting and decision-making module for real-time online evaluation, which provides warnings and makes decisions based on the monitoring information. From this, the monitoring information, evaluation results, maintenance decisions, and warning information can be input simultaneously into the bridge monitoring center and traffic emergency center to share the monitoring data, thereby facilitating evaluations and decision making using the system.

  18. Experimental Validation of a Resilient Monitoring and Control System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wen-Chiao Lin; Kris R. E. Villez; Humberto E. Garcia

    2014-05-01

    Complex, high performance, engineering systems have to be closely monitored and controlled to ensure safe operation and protect public from potential hazards. One of the main challenges in designing monitoring and control algorithms for these systems is that sensors and actuators may be malfunctioning due to malicious or natural causes. To address this challenge, this paper addresses a resilient monitoring and control (ReMAC) system by expanding previously developed resilient condition assessment monitoring systems and Kalman filter-based diagnostic methods and integrating them with a supervisory controller developed here. While the monitoring and diagnostic algorithms assess plant cyber and physical health conditions,more » the supervisory controller selects, from a set of candidates, the best controller based on the current plant health assessments. To experimentally demonstrate its enhanced performance, the developed ReMAC system is then used for monitoring and control of a chemical reactor with a water cooling system in a hardware-in-the-loop setting, where the reactor is computer simulated and the water cooling system is implemented by a machine condition monitoring testbed at Idaho National Laboratory. Results show that the ReMAC system is able to make correct plant health assessments despite sensor malfunctioning due to cyber attacks and make decisions that achieve best control actions despite possible actuator malfunctioning. Monitoring challenges caused by mismatches between assumed system component models and actual measurements are also identified for future work.« less

  19. IN VIVO AND IN VITRO ANTILEISHMANIAL EFFECTS OF METHANOLIC EXTRACT FROM BARK OF BURSERA APTERA.

    PubMed

    Nieto-Yañez, O J; Resendiz-Albor, A A; Ruiz-Hurtado, P A; Rivera-Yañez, N; Rodriguez-Canales, M; Rodriguez-Sosa, M; Juarez-Avelar, I; Rodriguez-Lopez, M G; Canales-Martinez, M M; Rodriguez-Monroy, M A

    2017-01-01

    Cutaneous leishmaniasis lacks effective and well-tolerated treatments. The current therapies mainly rely on antimonial drugs that are inadequate because of their poor efficacy. Traditional medicine offers a complementary alternative for the treatment of various diseases. Additionally, several plants have shown success as anti-leishmanial agents. Therefore, we sought to evaluate the in vitro and in vivo activity of MEBA against Leishmania mexicana . Methanolic extract of B. aptera was obtained by macetration, after we determined in vitro anti-leishmanial activity of MEBA by MTT assay and the induced apoptosis in promastigotes by flow cytometry. To analyze the in vivo anti-leishmanial activity, we used infected mice that were treated and not treated with MEBA and we determined the levels of cytokines using ELISA. The phytochemical properties were determined by CG-MS and DPPH assay. We determined of LC 50 of 0.408 mg/mL of MEBA for in vitro anti-leishmanial activity. MEBA induced apoptosis in promastigotes (15.3% ± 0.86). Treated mice exhibited smaller lesions and contained significantly fewer parasites than did untreated mice; in addition, we found that IFN-γ and TNF-α increased in the sera of MEBA-treated mice. GC-MS analysis showed that podophyllotoxin was the most abundant compound. Evaluation of the activity by DPPH assay demonstrated an SC 50 of 11.72 μg/mL. Based on the above data, it was concluded that MEBA is a good candidate in the search for new anti-leishmanial agents.

  20. 45 CFR 310.40 - What requirements apply for accessing systems and records for monitoring Computerized Tribal IV-D...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... records for monitoring Computerized Tribal IV-D Systems and Office Automation? 310.40 Section 310.40... COMPUTERIZED TRIBAL IV-D SYSTEMS AND OFFICE AUTOMATION Accountability and Monitoring Procedures for... monitoring Computerized Tribal IV-D Systems and Office Automation? In accordance with Part 95 of this title...

  1. 40 CFR 60.1760 - What is required for my continuous opacity monitoring system and how are the data used?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... opacity monitoring system and how are the data used? 60.1760 Section 60.1760 Protection of Environment... continuous opacity monitoring system and how are the data used? (a) Install, calibrate, maintain, and operate a continuous opacity monitoring system. (b) Install, evaluate, and operate each continuous opacity...

  2. 40 CFR 62.15225 - What must I do if my continuous emission monitoring system is temporarily unavailable to meet the...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... emission monitoring system is temporarily unavailable to meet the data collection requirements? 62.15225... Emission Monitoring § 62.15225 What must I do if my continuous emission monitoring system is temporarily... methods for collecting data when these systems malfunction or when repairs, calibration checks, or zero...

  3. 40 CFR Table 6 to Subpart Bbbb of... - Model Rule-Requirements for Validating Continuous Emission Monitoring Systems (CEMS)

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Continuous Emission Monitoring Systems (CEMS) 6 Table 6 to Subpart BBBB of Part 60 Protection of Environment...—Requirements for Validating Continuous Emission Monitoring Systems (CEMS) For the following continuous emission monitoring systems Use the following methods in appendix A of this part to validate poollutant concentratin...

  4. 40 CFR 60.1770 - What must I do if any of my continuous emission monitoring systems are temporarily unavailable to...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... emission monitoring systems are temporarily unavailable to meet the data collection requirements? 60.1770... Emission Monitoring § 60.1770 What must I do if any of my continuous emission monitoring systems are... alternate methods for collecting data when systems malfunction or when repairs, calibration checks, or zero...

  5. 40 CFR 62.15225 - What must I do if my continuous emission monitoring system is temporarily unavailable to meet the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... emission monitoring system is temporarily unavailable to meet the data collection requirements? 62.15225... Emission Monitoring § 62.15225 What must I do if my continuous emission monitoring system is temporarily... methods for collecting data when these systems malfunction or when repairs, calibration checks, or zero...

  6. 40 CFR Table 6 to Subpart Bbbb of... - Model Rule-Requirements for Validating Continuous Emission Monitoring Systems (CEMS)

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Continuous Emission Monitoring Systems (CEMS) 6 Table 6 to Subpart BBBB of Part 60 Protection of Environment...—Requirements for Validating Continuous Emission Monitoring Systems (CEMS) For the following continuous emission monitoring systems Use the following methods in appendix A of this part to validate poollutant concentratin...

  7. 40 CFR 62.15215 - What is required for my continuous opacity monitoring system and how are the data used?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... opacity monitoring system and how are the data used? 62.15215 Section 62.15215 Protection of Environment... required for my continuous opacity monitoring system and how are the data used? (a) Install, calibrate, maintain, and operate a continuous opacity monitoring system. (b) Install, evaluate, and operate each...

  8. 40 CFR 60.1770 - What must I do if any of my continuous emission monitoring systems are temporarily unavailable to...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... emission monitoring systems are temporarily unavailable to meet the data collection requirements? 60.1770... Emission Monitoring § 60.1770 What must I do if any of my continuous emission monitoring systems are... alternate methods for collecting data when systems malfunction or when repairs, calibration checks, or zero...

  9. INDUCTION OF CELL CYCLE ARREST AND APOPTOSIS BY ORMENIS ERIOLEPIS A MORROCAN ENDEMIC PLANT IN VARIOUS HUMAN CANCER CELL LINES

    PubMed Central

    Belayachi, Lamiae; Aceves-Luquero, Clara; Merghoub, Nawel; de Mattos, Silvia Fernández; Amzazi, Saaîd; Villalonga, Priam; Bakri, Youssef

    2017-01-01

    Background: Ormenis eriolepis Coss (Asteraceae) is an endemic Moroccan subspecies, traditionally named “Hellala” or “Fergoga”. It’s usually used for its hypoglycemic effect as well as for the treatment of stomacal pain. As far as we know, there is no scientific exploration of anti tumoral activity of Ormenis eriolepis extracts. Materials and Methods: In this regard, we performed a screening of organic extracts and fractions in a panel of both hematological and solid cancer cell lines, to evaluate the potential in vitro anti tumoral activity and to elucidate the respective mechanisms that may be responsible for growth arrest and cell death induction. The plant was extracted using organic solvents, and four different extracts were screened on Jurkat, Jeko-1, TK-6, LN229, SW620, U2OS, PC-3 and NIH3T3 cells. Results: Cell viability assays revealed that, the IC50 values were (11,63±5,37μg/ml) for Jurkat, (13,33±1,67μg/ml) for Jeko-1, (41,67±1,98μg/ml) for LN229 and (19,31±4,88μg/ml) for PC-3 cells upon treatment with Oe-DF and Oe-HE respectively. Both the fraction and extract exhibited no effects on TK6 and NIH3T3. Cytometry analysis accompanied by DNA damage signaling protein levels monitoring (p-H2A.X), showed that both the Dichloromethane Fraction and Hexanic extract induce DNA double stranded breaks (DSBs) accompanied by cell cycle arrest in G1 (Jurkat, Jeko -1 and LN22) and G2/M (PC-3) phases which is agreed with the caspase activity observed. Additional experiments with selective inhibitors of stress and survival pathways (JNK, MAPK, Rho, p53, and JAK3) indicated that none of these pathways was significantly involved in apoptosis induction. The bioactive compound analysis by CG/MS indicated that the major compounds in Oe-DF were: Linoleic Acid (15,89%), Podophyllotoxin (17,89%) and Quercetin (22,95%). For Oe-HE the major molecules were: Linoleic Acid (9,76%), α-curcumene (7,07%), α-bisabolol (5,49%), Campesterol (4,41%), Stigmasterol (14,08%) and β-sitosterol (7,49%). Conclusion: Our data suggest that bioactive compounds present in Ormenis eriolepis show significant anti proliferative activity inducing cell cycle arrest and cell death operating through apoptosis pathway. PMID:28573252

  10. Expert systems for real-time monitoring and fault diagnosis

    NASA Technical Reports Server (NTRS)

    Edwards, S. J.; Caglayan, A. K.

    1989-01-01

    Methods for building real-time onboard expert systems were investigated, and the use of expert systems technology was demonstrated in improving the performance of current real-time onboard monitoring and fault diagnosis applications. The potential applications of the proposed research include an expert system environment allowing the integration of expert systems into conventional time-critical application solutions, a grammar for describing the discrete event behavior of monitoring and fault diagnosis systems, and their applications to new real-time hardware fault diagnosis and monitoring systems for aircraft.

  11. 77 FR 551 - Privacy Act of 1974; Amended System of Records

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-05

    ... Act system of records entitled ``Treasury/BEP .027--Access Control and Alarm Monitoring Systems (ACAMS... .027--Access Control and Alarm Monitoring Systems (ACAMS).'' BEP proposes to amend that system of... records entitled ``BEP .027--Access Control and Alarm Monitoring Systems (ACAMS),'' as follows: Treasury...

  12. Smart Vest: wearable multi-parameter remote physiological monitoring system.

    PubMed

    Pandian, P S; Mohanavelu, K; Safeer, K P; Kotresh, T M; Shakunthala, D T; Gopal, Parvati; Padaki, V C

    2008-05-01

    The wearable physiological monitoring system is a washable shirt, which uses an array of sensors connected to a central processing unit with firmware for continuously monitoring physiological signals. The data collected can be correlated to produce an overall picture of the wearer's health. In this paper, we discuss the wearable physiological monitoring system called 'Smart Vest'. The Smart Vest consists of a comfortable to wear vest with sensors integrated for monitoring physiological parameters, wearable data acquisition and processing hardware and remote monitoring station. The wearable data acquisition system is designed using microcontroller and interfaced with wireless communication and global positioning system (GPS) modules. The physiological signals monitored are electrocardiogram (ECG), photoplethysmogram (PPG), body temperature, blood pressure, galvanic skin response (GSR) and heart rate. The acquired physiological signals are sampled at 250samples/s, digitized at 12-bit resolution and transmitted wireless to a remote physiological monitoring station along with the geo-location of the wearer. The paper describes a prototype Smart Vest system used for remote monitoring of physiological parameters and the clinical validation of the data are also presented.

  13. High-Performance Monitoring Architecture for Large-Scale Distributed Systems Using Event Filtering

    NASA Technical Reports Server (NTRS)

    Maly, K.

    1998-01-01

    Monitoring is an essential process to observe and improve the reliability and the performance of large-scale distributed (LSD) systems. In an LSD environment, a large number of events is generated by the system components during its execution or interaction with external objects (e.g. users or processes). Monitoring such events is necessary for observing the run-time behavior of LSD systems and providing status information required for debugging, tuning and managing such applications. However, correlated events are generated concurrently and could be distributed in various locations in the applications environment which complicates the management decisions process and thereby makes monitoring LSD systems an intricate task. We propose a scalable high-performance monitoring architecture for LSD systems to detect and classify interesting local and global events and disseminate the monitoring information to the corresponding end- points management applications such as debugging and reactive control tools to improve the application performance and reliability. A large volume of events may be generated due to the extensive demands of the monitoring applications and the high interaction of LSD systems. The monitoring architecture employs a high-performance event filtering mechanism to efficiently process the large volume of event traffic generated by LSD systems and minimize the intrusiveness of the monitoring process by reducing the event traffic flow in the system and distributing the monitoring computation. Our architecture also supports dynamic and flexible reconfiguration of the monitoring mechanism via its Instrumentation and subscription components. As a case study, we show how our monitoring architecture can be utilized to improve the reliability and the performance of the Interactive Remote Instruction (IRI) system which is a large-scale distributed system for collaborative distance learning. The filtering mechanism represents an Intrinsic component integrated with the monitoring architecture to reduce the volume of event traffic flow in the system, and thereby reduce the intrusiveness of the monitoring process. We are developing an event filtering architecture to efficiently process the large volume of event traffic generated by LSD systems (such as distributed interactive applications). This filtering architecture is used to monitor collaborative distance learning application for obtaining debugging and feedback information. Our architecture supports the dynamic (re)configuration and optimization of event filters in large-scale distributed systems. Our work represents a major contribution by (1) survey and evaluating existing event filtering mechanisms In supporting monitoring LSD systems and (2) devising an integrated scalable high- performance architecture of event filtering that spans several kev application domains, presenting techniques to improve the functionality, performance and scalability. This paper describes the primary characteristics and challenges of developing high-performance event filtering for monitoring LSD systems. We survey existing event filtering mechanisms and explain key characteristics for each technique. In addition, we discuss limitations with existing event filtering mechanisms and outline how our architecture will improve key aspects of event filtering.

  14. 40 CFR 60.2170 - Is there a minimum amount of monitoring data I must obtain?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... monitoring system quality assurance or quality control activities (including, as applicable, calibration... required monitoring system quality assurance or quality control activities including, as applicable... required monitoring system quality assurance or control activities in calculations used to report emissions...

  15. 40 CFR 63.567 - Recordkeeping and reporting requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... emissions and monitoring system performance reports—(1) Schedule for summary report and excess emissions and monitoring system performance reports. Excess emissions and parameter monitoring exceedances are defined in... install a CMS shall submit an excess emissions and continuous monitoring system performance report and/or...

  16. 40 CFR 60.3040 - What is my schedule for evaluating continuous emission monitoring systems?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... continuous emission monitoring systems? 60.3040 Section 60.3040 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES... continuous emission monitoring systems? (a) Conduct annual evaluations of your continuous emission monitoring...

  17. Remote monitoring system for the cryogenic system of superconducting magnets in the SuperKEKB interaction region

    NASA Astrophysics Data System (ADS)

    Aoki, K.; Ohuchi, N.; Zong, Z.; Arimoto, Y.; Wang, X.; Yamaoka, H.; Kawai, M.; Kondou, Y.; Makida, Y.; Hirose, M.; Endou, T.; Iwasaki, M.; Nakamura, T.

    2017-12-01

    A remote monitoring system was developed based on the software infrastructure of the Experimental Physics and Industrial Control System (EPICS) for the cryogenic system of superconducting magnets in the interaction region of the SuperKEKB accelerator. The SuperKEKB has been constructed to conduct high-energy physics experiments at KEK. These superconducting magnets consist of three apparatuses, the Belle II detector solenoid, and QCSL and QCSR accelerator magnets. They are each contained in three cryostats cooled by dedicated helium cryogenic systems. The monitoring system was developed to read data of the EX-8000, which is an integrated instrumentation system to control all cryogenic components. The monitoring system uses the I/O control tools of EPICS software for TCP/IP, archiving techniques using a relational database, and easy human-computer interface. Using this monitoring system, it is possible to remotely monitor all real-time data of the superconducting magnets and cryogenic systems. It is also convenient to share data among multiple groups.

  18. Real-Time Remote Monitoring with Data Acquisition System

    NASA Astrophysics Data System (ADS)

    Faizal Zainal Abidin, Ahmad; Huzaimy Jusoh, Mohammad; James, Elster; Junid, Syed Abdul Mutalib Al; Mohd Yassin, Ahmad Ihsan

    2015-11-01

    The purpose of this system is to provide monitoring system for an electrical device and enable remote monitoring via web based application. This monitoring system allow the user to monitor the device condition from anywhere as the information will be synchronised to the website. The current and voltage reading of the monitored equipment, ambient temperature and humidity level are monitored and recorded. These parameters will be updated on the web page. All these sensor are connected to the microcontroller and the data will saved in micro secure digital (SD) card and send all the gathered information to a web page using the GPRS service connection synchronously. The collected data will be displayed on the website and the user enable to download the data directly from the website. The system will help user to monitor the devices condition and ambient changes with ease. The system is successfully developed, tested and has been installed at residential area in Taman Cahaya Alam, Section U12, Shah Alam, Selangor, Malaysia.

  19. Definition, Capabilities, and Components of a Terrestrial Carbon Monitoring System

    NASA Technical Reports Server (NTRS)

    West, Tristram O.; Brown, Molly E.; Duren, Riley M.; Ogle, Stephen M.; Moss, Richard H.

    2013-01-01

    Research efforts for effectively and consistently monitoring terrestrial carbon are increasing in number. As such, there is a need to define carbon monitoring and how it relates to carbon cycle science and carbon management. There is also a need to identify capabilities of a carbon monitoring system and the system components needed to develop the capabilities. Capabilities that enable the effective application of a carbon monitoring system for monitoring and management purposes may include: reconciling carbon stocks and fluxes, developing consistency across spatial and temporal scales, tracking horizontal movement of carbon, attribution of emissions to originating sources, cross-sectoral accounting, uncertainty quantification, redundancy and policy relevance. Focused research is needed to integrate these capabilities for sustained estimates of carbon stocks and fluxes. Additionally, if monitoring is intended to inform management decisions, management priorities should be considered prior to development of a monitoring system.

  20. Development of on-line monitoring system for Nuclear Power Plant (NPP) using neuro-expert, noise analysis, and modified neural networks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Subekti, M.; Center for Development of Reactor Safety Technology, National Nuclear Energy Agency of Indonesia, Puspiptek Complex BO.80, Serpong-Tangerang, 15340; Ohno, T.

    2006-07-01

    The neuro-expert has been utilized in previous monitoring-system research of Pressure Water Reactor (PWR). The research improved the monitoring system by utilizing neuro-expert, conventional noise analysis and modified neural networks for capability extension. The parallel method applications required distributed architecture of computer-network for performing real-time tasks. The research aimed to improve the previous monitoring system, which could detect sensor degradation, and to perform the monitoring demonstration in High Temperature Engineering Tested Reactor (HTTR). The developing monitoring system based on some methods that have been tested using the data from online PWR simulator, as well as RSG-GAS (30 MW research reactormore » in Indonesia), will be applied in HTTR for more complex monitoring. (authors)« less

  1. An Integrated Patient Information and In-Home Health Monitoring System Using Smartphones and Web Services.

    PubMed

    Sorwar, Golam; Ali, Mortuza; Islam, Md Kamrul; Miah, Mohammad Selim

    2016-01-01

    Modern healthcare systems are undergoing a paradigm shift from in-hospital care to in-home monitoring, leveraging the emerging technologies in the area of bio-sensing, wireless communication, mobile computing, and artificial intelligence. In-home monitoring promises to significantly reduce healthcare spending by preventing unnecessary hospital admissions and visits to healthcare professionals. Most of the in-home monitoring systems, proposed in the literature, focus on monitoring a set of specific vital signs. However, from the perspective of caregivers it is infeasible to maintain a collection of specialized monitoring systems. In this paper, we view the problem of in-home monitoring from the perspective of caregivers and present a framework that supports various monitoring capabilities while making the complexity transparent to the end users. The essential idea of the framework is to define a 'general purpose architecture' where the system specifies a particular protocol for communication and makes it public. Then any bio-sensing system can communicate with the system as long as it conforms to the protocol. We then argue that as the system grows in terms of number of patients and bio-sensing systems, artificial intelligence technologies need to be employed for patients' risk assessment, prioritization, and recommendation. Finally, we present an initial prototype of the system designed according to the proposed framework.

  2. Design and Development of Patient Monitoring System

    NASA Astrophysics Data System (ADS)

    Hazwanie Azizulkarim, Azra; Jamil, Muhammad Mahadi Abdul; Ambar, Radzi

    2017-08-01

    Patient monitoring system allows continuous monitoring of patient vital signs, support decision making among medical personnel and help enhance patient care. This system can consist of devices that measure, display and record human’s vital signs, including body temperature, heart rate, blood pressure and other health-related criteria. This paper proposes a system to monitor the patient’s conditions by monitoring the body temperature and pulse rate. The system consists of a pulse rate monitoring software and a wearable device that can measure a subject’s temperature and pulse rate only by using a fingertip. The device is able to record the measurement data and interface to PC via Arduino microcontroller. The recorded data can be viewed as a historical file or can be archived for further analysis. This work also describes the preliminary experimental results of the selected sensors to show the usefulness of the sensors for the proposed patient monitoring system.

  3. Integrated wireless sensor network and real time smart controlling and monitoring system for efficient energy management in standalone photovoltaic systems

    NASA Astrophysics Data System (ADS)

    Abou-Elnour, Ali; Thabt, A.; Helmy, S.; Kashf, Y.; Hadad, Y.; Tarique, M.; Abo-Elnor, Ossama

    2014-04-01

    In the present work, wireless sensor network and smart real-time controlling and monitoring system are integrated for efficient energy management of standalone photovoltaic system. The proposed system has two main components namely the monitoring and controlling system and the wireless communication system. LabView software has been used in the implementation of the monitoring and controlling system. On the other hand, ZigBee wireless modules have been used to implement the wireless system. The main functions of monitoring and controlling unit is to efficiently control the energy consumption form the photovoltaic system based on accurate determination of the periods of times at which the loads are required to be operated. The wireless communication system send the data from the monitoring and controlling unit to the loads at which desired switching operations are performed. The wireless communication system also continuously feeds the monitoring and controlling unit with updated input data from the sensors and from the photovoltaic module send to calculate and record the generated, the consumed, and the stored energy to apply load switching saving schemes if necessary. It has to be mentioned that our proposed system is a low cost and low power system because and it is flexible to be upgraded to fulfill additional users' requirements.

  4. The development of a tele-monitoring system for physiological parameters based on the B/S model.

    PubMed

    Shuicai, Wu; Peijie, Jiang; Chunlan, Yang; Haomin, Li; Yanping, Bai

    2010-01-01

    The development of a new physiological multi-parameter remote monitoring system is based on the B/S model. The system consists of a server monitoring center, Internet network and PC-based multi-parameter monitors. Using the B/S model, the clients can browse web pages via the server monitoring center and download and install ActiveX controls. The physiological multi-parameters are collected, displayed and remotely transmitted. The experimental results show that the system is stable, reliable and operates in real time. The system is suitable for use in physiological multi-parameter remote monitoring for family and community healthcare. Copyright © 2010 Elsevier Ltd. All rights reserved.

  5. Implementation of a Portable Personal EKG Signal Monitoring System

    NASA Astrophysics Data System (ADS)

    Tan, Tan-Hsu; Chang, Ching-Su; Chen, Yung-Fu; Lee, Cheng

    This research develops a portable personal EKG signal monitoring system to help patients monitor their EKG signals instantly to avoid the occurrence of tragedies. This system is built with two main units: signal pro-cessing unit and monitoring and evaluation unit. The first unit consists of EKG signal sensor, signal amplifier, digitalization circuit, and related control circuits. The second unit is a software tool developed on an embedded Linux platform (called CSA). Experimental result indicates that the proposed system has the practical potential for users in health monitoring. It is demonstrated to be more convenient and with greater portability than the conventional PC-based EKG signal monitoring systems. Furthermore, all the application units embedded in the system are built with open source codes, no licensed fee is required for operating systems and authorized applications. Thus, the building cost is much lower than the traditional systems.

  6. A Fully Redundant On-Line Mass Spectrometer System Used to Monitor Cryogenic Fuel Leaks on the Space Shuttle

    NASA Technical Reports Server (NTRS)

    Griffin, Timothy P.; Naylor, Guy R.; Haskell, William D.; Breznik, Greg S.; Mizell, Carolyn A.; Helms, William R.; Voska, N. (Technical Monitor)

    2002-01-01

    An on-line gas monitoring system was developed to replace the older systems used to monitor for cryogenic leaks on the Space Shuttles before launch. The system uses a mass spectrometer to monitor multiple locations in the process, which allows the system to monitor all gas constituents of interest in a nearly simultaneous manner. The system is fully redundant and meets all requirements for ground support equipment (GSE). This includes ruggedness to withstand launch on the Mobile Launcher Platform (MLP), ease of operation, and minimal operator intervention. The system can be fully automated so that an operator is notified when an unusual situation or fault is detected. User inputs are through personal computer using mouse and keyboard commands. The graphical user for detecting cryogenic leaks, many other gas constituents could be monitored using the Hazardous Gas Detection System (HGDS) 2000.

  7. 47 CFR 76.614 - Cable television system regular monitoring.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 4 2013-10-01 2013-10-01 false Cable television system regular monitoring. 76... system regular monitoring. Cable television operators transmitting carriers in the frequency bands 108-137 and 225-400 MHz shall provide for a program of regular monitoring for signal leakage by...

  8. 47 CFR 76.614 - Cable television system regular monitoring.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 4 2012-10-01 2012-10-01 false Cable television system regular monitoring. 76... system regular monitoring. Cable television operators transmitting carriers in the frequency bands 108-137 and 225-400 MHz shall provide for a program of regular monitoring for signal leakage by...

  9. 47 CFR 76.614 - Cable television system regular monitoring.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 4 2014-10-01 2014-10-01 false Cable television system regular monitoring. 76... system regular monitoring. Cable television operators transmitting carriers in the frequency bands 108-137 and 225-400 MHz shall provide for a program of regular monitoring for signal leakage by...

  10. Visual monitoring of autonomous life sciences experimentation

    NASA Technical Reports Server (NTRS)

    Blank, G. E.; Martin, W. N.

    1987-01-01

    The design and implementation of a computerized visual monitoring system to aid in the monitoring and control of life sciences experiments on board a space station was investigated. A likely multiprocessor design was chosen, a plausible life science experiment with which to work was defined, the theoretical issues involved in the programming of a visual monitoring system for the experiment was considered on the multiprocessor, a system for monitoring the experiment was designed, and simulations of such a system was implemented on a network of Apollo workstations.

  11. System for monitoring non-coincident, nonstationary process signals

    DOEpatents

    Gross, Kenneth C.; Wegerich, Stephan W.

    2005-01-04

    An improved system for monitoring non-coincident, non-stationary, process signals. The mean, variance, and length of a reference signal is defined by an automated system, followed by the identification of the leading and falling edges of a monitored signal and the length of the monitored signal. The monitored signal is compared to the reference signal, and the monitored signal is resampled in accordance with the reference signal. The reference signal is then correlated with the resampled monitored signal such that the reference signal and the resampled monitored signal are coincident in time with each other. The resampled monitored signal is then compared to the reference signal to determine whether the resampled monitored signal is within a set of predesignated operating conditions.

  12. A reliable low cost integrated wireless sensor network for water quality monitoring and level control system in UAE

    NASA Astrophysics Data System (ADS)

    Abou-Elnour, Ali; Khaleeq, Hyder; Abou-Elnour, Ahmad

    2016-04-01

    In the present work, wireless sensor network and real-time controlling and monitoring system are integrated for efficient water quality monitoring for environmental and domestic applications. The proposed system has three main components (i) the sensor circuits, (ii) the wireless communication system, and (iii) the monitoring and controlling unit. LabView software has been used in the implementation of the monitoring and controlling system. On the other hand, ZigBee and myRIO wireless modules have been used to implement the wireless system. The water quality parameters are accurately measured by the present computer based monitoring system and the measurement results are instantaneously transmitted and published with minimum infrastructure costs and maximum flexibility in term of distance or location. The mobility and durability of the proposed system are further enhanced by fully powering via a photovoltaic system. The reliability and effectiveness of the system are evaluated under realistic operating conditions.

  13. A computerized assessment to compare the impact of standard, stereoscopic, and high-definition laparoscopic monitor displays on surgical technique.

    PubMed

    Feng, Chuan; Rozenblit, Jerzy W; Hamilton, Allan J

    2010-11-01

    Surgeons performing laparoscopic surgery have strong biases regarding the quality and nature of the laparoscopic video monitor display. In a comparative study, we used a unique computerized sensing and analysis system to evaluate the various types of monitors employed in laparoscopic surgery. We compared the impact of different types of monitor displays on an individual's performance of a laparoscopic training task which required the subject to move the instrument to a set of targets. Participants (varying from no laparoscopic experience to board-certified surgeons) were asked to perform the assigned task while using all three display systems, which were randomly assigned: a conventional laparoscopic monitor system (2D), a high-definition monitor system (HD), and a stereoscopic display (3D). The effects of monitor system on various performance parameters (total time consumed to finish the task, average speed, and movement economy) were analyzed by computer. Each of the subjects filled out a subjective questionnaire at the end of their training session. A total of 27 participants completed our study. Performance with the HD monitor was significantly slower than with either the 3D or 2D monitor (p < 0.0001). Movement economy with the HD monitor was significantly reduced compared with the 3D (p < 0.0004) or 2D (p < 0.0001) monitor. In terms of average time required to complete the task, performance with the 3D monitor was significantly faster than with the HD (p < 0.0001) or 2D (p < 0.0086) monitor. However, the HD system was the overwhelming favorite according to subjective evaluation. Computerized sensing and analysis is capable of quantitatively assessing the seemingly minor effect of monitor display on surgical training performance. The study demonstrates that, while users expressed a decided preference for HD systems, actual quantitative analysis indicates that HD monitors offer no statistically significant advantage and may even worsen performance compared with standard 2D or 3D laparoscopic monitors.

  14. 23 CFR 500.201 - Purpose.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... AND MONITORING SYSTEMS Traffic Monitoring System § 500.201 Purpose. The purpose of this subpart is to... traffic monitoring system for highways and public transportation facilities and equipment (TMS) in each...

  15. Design and implementation of a 3-lead ECG wireless remote monitoring system

    NASA Astrophysics Data System (ADS)

    Zhang, Shi; Jia, Xiaonan; Shang, Shuai

    2006-11-01

    Cardiovascular disease is one of the main diseases that menaces human health. It is necessary to monitor the patient's real-time electrocardiograph (ECG) for a long time to realize diagnosis and salvage. Remote ECG monitoring system is the solution. This paper introduces the design and implement of a 3-lead ECG wireless remote monitoring system. It collects, stores and transmits user's ECG which can be received by hospital and diagnosed by doctors. The development of the whole system contains three parts, the hardware and embedded software implementation of MONITOR, software of the MONITORING CENTER, and the routing software of NETWORK CENTER. According to the clinic experimentation, this system has high reliability and utility. There will be great social and economic benefit if this system is put into use.

  16. 75 FR 52711 - Notice of Request for Approval of an Information Collection; National Animal Health Monitoring...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-27

    ...] Notice of Request for Approval of an Information Collection; National Animal Health Monitoring System... to support the National Animal Health Monitoring System Sheep 2011 Study. DATES: We will consider all... Coordinator, at (301) 851-2908. SUPPLEMENTARY INFORMATION: Title: National Animal Health Monitoring System...

  17. 40 CFR 258.51 - Ground-water monitoring systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 26 2013-07-01 2013-07-01 false Ground-water monitoring systems. 258.51 Section 258.51 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES CRITERIA FOR MUNICIPAL SOLID WASTE LANDFILLS Ground-Water Monitoring and Corrective Action § 258.51 Ground-water monitoring systems. (a) A...

  18. 40 CFR 60.1235 - How are the data from the continuous emission monitoring systems used?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... emission monitoring systems used? 60.1235 Section 60.1235 Protection of Environment ENVIRONMENTAL... Continuous Emission Monitoring § 60.1235 How are the data from the continuous emission monitoring systems... oxides, and carbon monoxide to demonstrate continuous compliance with the emission limits specified in...

  19. 40 CFR 60.1235 - How are the data from the continuous emission monitoring systems used?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... emission monitoring systems used? 60.1235 Section 60.1235 Protection of Environment ENVIRONMENTAL... Continuous Emission Monitoring § 60.1235 How are the data from the continuous emission monitoring systems... oxides, and carbon monoxide to demonstrate continuous compliance with the emission limits specified in...

  20. 40 CFR 60.1235 - How are the data from the continuous emission monitoring systems used?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... emission monitoring systems used? 60.1235 Section 60.1235 Protection of Environment ENVIRONMENTAL... Continuous Emission Monitoring § 60.1235 How are the data from the continuous emission monitoring systems... oxides, and carbon monoxide to demonstrate continuous compliance with the emission limits specified in...

  1. The arrangement of deformation monitoring project and analysis of monitoring data of a hydropower engineering safety monitoring system

    NASA Astrophysics Data System (ADS)

    Wang, Wanshun; Chen, Zhuo; Li, Xiuwen

    2018-03-01

    The safety monitoring is very important in the operation and management of water resources and hydropower projects. It is the important means to understand the dam running status, to ensure the dam safety, to safeguard people’s life and property security, and to make full use of engineering benefits. This paper introduces the arrangement of engineering safety monitoring system based on the example of a water resource control project. The monitoring results of each monitoring project are analyzed intensively to show the operating status of the monitoring system and to provide useful reference for similar projects.

  2. Distributed Interplanetary Delay/Disruption Tolerant Network (DTN) Monitor and Control System

    NASA Technical Reports Server (NTRS)

    Wang, Shin-Ywan

    2012-01-01

    The main purpose of Distributed interplanetary Delay Tolerant Network Monitor and Control System as a DTN system network management implementation in JPL is defined to provide methods and tools that can monitor the DTN operation status, detect and resolve DTN operation failures in some automated style while either space network or some heterogeneous network is infused with DTN capability. In this paper, "DTN Monitor and Control system in Deep Space Network (DSN)" exemplifies a case how DTN Monitor and Control system can be adapted into a space network as it is DTN enabled.

  3. On the use of multi-agent systems for the monitoring of industrial systems

    NASA Astrophysics Data System (ADS)

    Rezki, Nafissa; Kazar, Okba; Mouss, Leila Hayet; Kahloul, Laid; Rezki, Djamil

    2016-03-01

    The objective of the current paper is to present an intelligent system for complex process monitoring, based on artificial intelligence technologies. This system aims to realize with success all the complex process monitoring tasks that are: detection, diagnosis, identification and reconfiguration. For this purpose, the development of a multi-agent system that combines multiple intelligences such as: multivariate control charts, neural networks, Bayesian networks and expert systems has became a necessity. The proposed system is evaluated in the monitoring of the complex process Tennessee Eastman process.

  4. Implementation monitoring temperature, humidity and mositure soil based on wireless sensor network for e-agriculture technology

    NASA Astrophysics Data System (ADS)

    Sumarudin, A.; Ghozali, A. L.; Hasyim, A.; Effendi, A.

    2016-04-01

    Indonesian agriculture has great potensial for development. Agriculture a lot yet based on data collection for soil or plant, data soil can use for analys soil fertility. We propose e-agriculture system for monitoring soil. This system can monitoring soil status. Monitoring system based on wireless sensor mote that sensing soil status. Sensor monitoring utilize soil moisture, humidity and temperature. System monitoring design with mote based on microcontroler and xbee connection. Data sensing send to gateway with star topology with one gateway. Gateway utilize with mini personal computer and connect to xbee cordinator mode. On gateway, gateway include apache server for store data based on My-SQL. System web base with YII framework. System done implementation and can show soil status real time. Result the system can connection other mote 40 meters and mote lifetime 7 hours and minimum voltage 7 volt. The system can help famer for monitoring soil and farmer can making decision for treatment soil based on data. It can improve the quality in agricultural production and would decrease the management and farming costs.

  5. Integration of structural health monitoring and asset management.

    DOT National Transportation Integrated Search

    2012-08-01

    This project investigated the feasibility and potential benefits of the integration of infrastructure monitoring systems into enterprise-scale transportation management systems. An infrastructure monitoring system designed for bridges was implemented...

  6. Operational Monitoring of Data Production at KNMI

    NASA Astrophysics Data System (ADS)

    van de Vegte, John; Kwidama, Anecita; van Moosel, Wim; Oosterhof, Rijk; de Wit de Wit, Ronny; Klein Ikkink, Henk Jan; Som de Cerff, Wim; Verhoef, Hans; Koutek, Michal; Duin, Frank; van der Neut, Ian; verhagen, Robert; Wollerich, Rene

    2016-04-01

    Within KNMI a new fully automated system for monitoring the KNMI operational data production systems is being developed: PRISMA (PRocessflow Infrastructure Surveillance and Monitoring Application). Currently the KNMI operational (24/7) production systems consist of over 60 applications, running on different hardware systems and platforms. They are interlinked for the production of numerous data products, which are delivered to internal and external customers. Traditionally these applications are individually monitored by different applications or not at all; complicating root cause and impact analysis. Also, the underlying hardware and network is monitored via an isolated application. Goal of the PRISMA system is to enable production chain monitoring, which enables root cause analysis (what is the root cause of the disruption) and impact analysis (what downstream products/customers will be effected). The PRISMA system will make it possible to reduce existing monitoring applications and provides one interface for monitoring the data production. For modeling and storing the state of the production chains a graph database is used. The model is automatically updated by the applications and systems which are to be monitored. The graph models enables root cause and impact analysis. In the PRISMA web interface interaction with the graph model is accomplished via a graphical representation. The presentation will focus on aspects of: • Modeling real world computers, applications, products to a conceptual model; • Architecture of the system; • Configuration information and (real world) event handling of the to be monitored objects; • Implementation rules for root cause and impact analysis. • How PRISMA was developed (methodology, facts, results) • Presentation of the PRISMA system as it now looks and works

  7. Feasibility of a fetal measurement electrode system

    NASA Technical Reports Server (NTRS)

    1977-01-01

    Findings of the study are summarized and conclude that all monitoring requirements are not currently satisfied. An approach is presented to provide a multiparametric monitoring system through combinations of existing transducers. This monitoring system would be appropriate, not only for intrapartum monitoring, but also for neonatal and adult blood gas evaluations. A literature search was conducted to provide an insight into current state-of-the-art in fetal monitoring.

  8. A wireless portable system with microsensors for monitoring respiratory diseases.

    PubMed

    Cao, Zhe; Zhu, Rong; Que, Rui-Yi

    2012-11-01

    A wireless portable monitoring system for respiratory diseases using microsensors is proposed. The monitoring system consists of two sensor nodes integrating with Bluetooth transmitters that measure user's respiratory airflow, blood oxygen saturation, and body posture. The utility of micro-hot-film flow sensor makes the monitor can acquire comprehensive respiration parameters which are useful for diagnoses of obstructive sleep apnea, chronic obstructive pulmonary disease, and asthma. The system can serve as both sleep recorder and spirometer. Additionally, a mobile phone or a PC connected to the Internet serving as a monitoring and transfer terminal makes telemedicine achievable. Several experiments were conducted to verify the feasibility and effectiveness of the proposed system for monitoring and diagnosing OSA, COPD, and asthma.

  9. Object-oriented Approach to High-level Network Monitoring and Management

    NASA Technical Reports Server (NTRS)

    Mukkamala, Ravi

    2000-01-01

    An absolute prerequisite for the management of large investigating methods to build high-level monitoring computer networks is the ability to measure their systems that are built on top of existing monitoring performance. Unless we monitor a system, we cannot tools. Due to the heterogeneous nature of the hope to manage and control its performance. In this underlying systems at NASA Langley Research Center, paper, we describe a network monitoring system that we use an object-oriented approach for the design, we are currently designing and implementing. Keeping, first, we use UML (Unified Modeling Language) to in mind the complexity of the task and the required model users' requirements. Second, we identify the flexibility for future changes, we use an object-oriented existing capabilities of the underlying monitoring design methodology. The system is built using the system. Third, we try to map the former with the latter. APIs offered by the HP OpenView system.

  10. Development of a laboratory prototype water quality monitoring system suitable for use in zero gravity

    NASA Technical Reports Server (NTRS)

    Misselhorn, J. E.; Witz, S.; Hartung, W. H.

    1973-01-01

    The development of a laboratory prototype water quality monitoring system for use in the evaluation of candidate water recovery systems and for study of techniques for measuring potability parameters is reported. Sensing techniques for monitoring of the most desirable parameters are reviewed in terms of their sensitivities and complexities, and their recommendations for sensing techniques are presented. Rationale for selection of those parameters to be monitored (pH, specific conductivity, Cr(+6), I2, total carbon, and bacteria) in a next generation water monitor is presented along with an estimate of flight system specifications. A master water monitor development schedule is included.

  11. A Method of High Throughput Monitoring Crop Physiology Using Chlorophyll Fluorescence and Multispectral Imaging.

    PubMed

    Wang, Heng; Qian, Xiangjie; Zhang, Lan; Xu, Sailong; Li, Haifeng; Xia, Xiaojian; Dai, Liankui; Xu, Liang; Yu, Jingquan; Liu, Xu

    2018-01-01

    We present a high throughput crop physiology condition monitoring system and corresponding monitoring method. The monitoring system can perform large-area chlorophyll fluorescence imaging and multispectral imaging. The monitoring method can determine the crop current condition continuously and non-destructively. We choose chlorophyll fluorescence parameters and relative reflectance of multispectral as the indicators of crop physiological status. Using tomato as experiment subject, the typical crop physiological stress, such as drought, nutrition deficiency and plant disease can be distinguished by the monitoring method. Furthermore, we have studied the correlation between the physiological indicators and the degree of stress. Besides realizing the continuous monitoring of crop physiology, the monitoring system and method provide the possibility of machine automatic diagnosis of the plant physiology. Highlights: A newly designed high throughput crop physiology monitoring system and the corresponding monitoring method are described in this study. Different types of stress can induce distinct fluorescence and spectral characteristics, which can be used to evaluate the physiological status of plants.

  12. Wide-area, real-time monitoring and visualization system

    DOEpatents

    Budhraja, Vikram S.; Dyer, James D.; Martinez Morales, Carlos A.

    2013-03-19

    A real-time performance monitoring system for monitoring an electric power grid. The electric power grid has a plurality of grid portions, each grid portion corresponding to one of a plurality of control areas. The real-time performance monitoring system includes a monitor computer for monitoring at least one of reliability metrics, generation metrics, transmission metrics, suppliers metrics, grid infrastructure security metrics, and markets metrics for the electric power grid. The data for metrics being monitored by the monitor computer are stored in a data base, and a visualization of the metrics is displayed on at least one display computer having a monitor. The at least one display computer in one said control area enables an operator to monitor the grid portion corresponding to a different said control area.

  13. Wide-area, real-time monitoring and visualization system

    DOEpatents

    Budhraja, Vikram S [Los Angeles, CA; Dyer, James D [La Mirada, CA; Martinez Morales, Carlos A [Upland, CA

    2011-11-15

    A real-time performance monitoring system for monitoring an electric power grid. The electric power grid has a plurality of grid portions, each grid portion corresponding to one of a plurality of control areas. The real-time performance monitoring system includes a monitor computer for monitoring at least one of reliability metrics, generation metrics, transmission metrics, suppliers metrics, grid infrastructure security metrics, and markets metrics for the electric power grid. The data for metrics being monitored by the monitor computer are stored in a data base, and a visualization of the metrics is displayed on at least one display computer having a monitor. The at least one display computer in one said control area enables an operator to monitor the grid portion corresponding to a different said control area.

  14. Real-time performance monitoring and management system

    DOEpatents

    Budhraja, Vikram S [Los Angeles, CA; Dyer, James D [La Mirada, CA; Martinez Morales, Carlos A [Upland, CA

    2007-06-19

    A real-time performance monitoring system for monitoring an electric power grid. The electric power grid has a plurality of grid portions, each grid portion corresponding to one of a plurality of control areas. The real-time performance monitoring system includes a monitor computer for monitoring at least one of reliability metrics, generation metrics, transmission metrics, suppliers metrics, grid infrastructure security metrics, and markets metrics for the electric power grid. The data for metrics being monitored by the monitor computer are stored in a data base, and a visualization of the metrics is displayed on at least one display computer having a monitor. The at least one display computer in one said control area enables an operator to monitor the grid portion corresponding to a different said control area.

  15. 40 CFR 75.10 - General operating requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... part, a flow monitoring system and a CO2 continuous emission monitoring system that uses an O2...) Primary Measurement Requirement. The owner or operator shall measure opacity, and all SO2, NOX, and CO2... continuous emission monitoring system (consisting of a NOX pollutant concentration monitor and an O2 or CO2...

  16. 40 CFR 75.10 - General operating requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... part, a flow monitoring system and a CO2 continuous emission monitoring system that uses an O2...) Primary Measurement Requirement. The owner or operator shall measure opacity, and all SO2, NOX, and CO2... continuous emission monitoring system (consisting of a NOX pollutant concentration monitor and an O2 or CO2...

  17. 40 CFR 60.1240 - How do I make sure my continuous emission monitoring systems are operating correctly?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... emission monitoring systems are operating correctly? 60.1240 Section 60.1240 Protection of Environment... Continuous Emission Monitoring § 60.1240 How do I make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous...

  18. 40 CFR 60.2940 - How do I make sure my continuous emission monitoring systems are operating correctly?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... emission monitoring systems are operating correctly? 60.2940 Section 60.2940 Protection of Environment... 16, 2006 Monitoring § 60.2940 How do I make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous...

  19. 40 CFR 60.1240 - How do I make sure my continuous emission monitoring systems are operating correctly?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... emission monitoring systems are operating correctly? 60.1240 Section 60.1240 Protection of Environment... Continuous Emission Monitoring § 60.1240 How do I make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous...

  20. 40 CFR 60.2940 - How do I make sure my continuous emission monitoring systems are operating correctly?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... emission monitoring systems are operating correctly? 60.2940 Section 60.2940 Protection of Environment... 16, 2006 Monitoring § 60.2940 How do I make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous...

  1. 40 CFR 60.1240 - How do I make sure my continuous emission monitoring systems are operating correctly?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... emission monitoring systems are operating correctly? 60.1240 Section 60.1240 Protection of Environment... Continuous Emission Monitoring § 60.1240 How do I make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous...

  2. 40 CFR 60.1240 - How do I make sure my continuous emission monitoring systems are operating correctly?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... emission monitoring systems are operating correctly? 60.1240 Section 60.1240 Protection of Environment... Continuous Emission Monitoring § 60.1240 How do I make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous...

  3. 40 CFR 60.1240 - How do I make sure my continuous emission monitoring systems are operating correctly?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... emission monitoring systems are operating correctly? 60.1240 Section 60.1240 Protection of Environment... Continuous Emission Monitoring § 60.1240 How do I make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous...

  4. 75 FR 18110 - Antarctic Marine Living Resources; Use of Centralized-Vessel Monitoring System and Importation of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-09

    .... 0907141130-0112-02] RIN 0648-AX80 Antarctic Marine Living Resources; Use of Centralized-Vessel Monitoring... documentation that the harvesting vessel participated in the Centralized-Vessel Monitoring System (C-VMS... Centralized-Vessel Monitoring System (C-VMS) regardless of where the fish was harvested. This final rule also...

  5. 40 CFR 75.74 - Annual and ozone season monitoring and reporting requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... owner or operator of an affected unit subject both to an Acid Rain emission limitation and to a State or... State or federal NOX mass reduction program that adopts the provisions of this part and that requires...-diluent monitoring system, each flow rate monitoring system, each moisture monitoring system and each...

  6. 40 CFR 60.3038 - What continuous emission monitoring systems must I install?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... systems must I install? 60.3038 Section 60.3038 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... December 9, 2004 Model Rule-Monitoring § 60.3038 What continuous emission monitoring systems must I install... carbon monoxide and for oxygen. You must monitor the oxygen concentration at each location where you...

  7. 40 CFR 60.3038 - What continuous emission monitoring systems must I install?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... systems must I install? 60.3038 Section 60.3038 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... December 9, 2004 Model Rule-Monitoring § 60.3038 What continuous emission monitoring systems must I install... carbon monoxide and for oxygen. You must monitor the oxygen concentration at each location where you...

  8. 40 CFR 60.3038 - What continuous emission monitoring systems must I install?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... systems must I install? 60.3038 Section 60.3038 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... December 9, 2004 Model Rule-Monitoring § 60.3038 What continuous emission monitoring systems must I install... carbon monoxide and for oxygen. You must monitor the oxygen concentration at each location where you...

  9. Study on an agricultural environment monitoring server system using Wireless Sensor Networks.

    PubMed

    Hwang, Jeonghwan; Shin, Changsun; Yoe, Hyun

    2010-01-01

    This paper proposes an agricultural environment monitoring server system for monitoring information concerning an outdoors agricultural production environment utilizing Wireless Sensor Network (WSN) technology. The proposed agricultural environment monitoring server system collects environmental and soil information on the outdoors through WSN-based environmental and soil sensors, collects image information through CCTVs, and collects location information using GPS modules. This collected information is converted into a database through the agricultural environment monitoring server consisting of a sensor manager, which manages information collected from the WSN sensors, an image information manager, which manages image information collected from CCTVs, and a GPS manager, which processes location information of the agricultural environment monitoring server system, and provides it to producers. In addition, a solar cell-based power supply is implemented for the server system so that it could be used in agricultural environments with insufficient power infrastructure. This agricultural environment monitoring server system could even monitor the environmental information on the outdoors remotely, and it could be expected that the use of such a system could contribute to increasing crop yields and improving quality in the agricultural field by supporting the decision making of crop producers through analysis of the collected information.

  10. A Study about the 3S-based Great Ruins Monitoring and Early-warning System

    NASA Astrophysics Data System (ADS)

    Xuefeng, W.; Zhongyuan, H.; Gongli, L.; Li, Z.

    2015-08-01

    Large-scale urbanization construction and new countryside construction, frequent natural disasters, and natural corrosion pose severe threat to the great ruins. It is not uncommon that the cultural relics are damaged and great ruins are occupied. Now the ruins monitoring mainly adopt general monitoring data processing system which can not effectively exert management, display, excavation analysis and data sharing of the relics monitoring data. Meanwhile those general software systems require layout of large number of devices or apparatuses, but they are applied to small-scope relics monitoring only. Therefore, this paper proposes a method to make use of the stereoscopic cartographic satellite technology to improve and supplement the great ruins monitoring index system and combine GIS and GPS to establish a highly automatic, real-time and intelligent great ruins monitoring and early-warning system in order to realize collection, processing, updating, spatial visualization, analysis, distribution and sharing of the monitoring data, and provide scientific and effective data for the relics protection, scientific planning, reasonable development and sustainable utilization.

  11. 40 CFR 63.7535 - Is there a minimum amount of monitoring data I must obtain?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...-control periods, or required monitoring system quality assurance or control activities in data averages... required monitoring system quality assurance or quality control activities (including, as applicable... control activities. You must calculate monitoring results using all other monitoring data collected while...

  12. 40 CFR 63.7535 - Is there a minimum amount of monitoring data I must obtain?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...-control periods, or required monitoring system quality assurance or control activities in data averages... required monitoring system quality assurance or quality control activities (including, as applicable... control activities. You must calculate monitoring results using all other monitoring data collected while...

  13. 30 CFR 822.13 - Monitoring.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Monitoring. 822.13 Section 822.13 Mineral... § 822.13 Monitoring. (a) A monitoring system shall be installed, maintained, and operated by the... until all bonds are released in accordance with Subchapter J of this chapter. The monitoring system...

  14. Instantaneous angular speed monitoring of gearboxes under non-cyclic stationary load conditions

    NASA Astrophysics Data System (ADS)

    Stander, C. J.; Heyns, P. S.

    2005-07-01

    Recent developments in the condition monitoring and asset management market have led to the commercialisation of online vibration-monitoring systems. These systems are primarily utilised to monitor large mineral mining equipment such as draglines, continuous miners and hydraulic shovels. Online monitoring systems make diagnostic information continuously available for asset management, production outsourcing and maintenance alliances with equipment manufacturers. However, most online vibration-monitoring systems are based on conventional vibration-monitoring technologies, which are prone to giving false equipment deterioration warnings on gears that operate under fluctuating load conditions. A simplified mathematical model of a gear system was developed to illustrate the feasibility of monitoring the instantaneous angular speed (IAS) as a means of monitoring the condition of gears that are subjected to fluctuating load conditions. A distinction is made between cyclic stationary load modulation and non-cyclic stationary load modulation. It is shown that rotation domain averaging will suppress the modulation caused by non-cyclic stationary load conditions but will not suppress the modulation caused by cyclic stationary load conditions. An experimental investigation on a test rig indicated that the IAS of a gear shaft could be monitored with a conventional shaft encoder to indicate a deteriorating gear fault condition.

  15. Winter wheat quality monitoring and forecasting system based on remote sensing and environmental factors

    NASA Astrophysics Data System (ADS)

    Haiyang, Yu; Yanmei, Liu; Guijun, Yang; Xiaodong, Yang; Dong, Ren; Chenwei, Nie

    2014-03-01

    To achieve dynamic winter wheat quality monitoring and forecasting in larger scale regions, the objective of this study was to design and develop a winter wheat quality monitoring and forecasting system by using a remote sensing index and environmental factors. The winter wheat quality trend was forecasted before the harvest and quality was monitored after the harvest, respectively. The traditional quality-vegetation index from remote sensing monitoring and forecasting models were improved. Combining with latitude information, the vegetation index was used to estimate agronomy parameters which were related with winter wheat quality in the early stages for forecasting the quality trend. A combination of rainfall in May, temperature in May, illumination at later May, the soil available nitrogen content and other environmental factors established the quality monitoring model. Compared with a simple quality-vegetation index, the remote sensing monitoring and forecasting model used in this system get greatly improved accuracy. Winter wheat quality was monitored and forecasted based on the above models, and this system was completed based on WebGIS technology. Finally, in 2010 the operation process of winter wheat quality monitoring system was presented in Beijing, the monitoring and forecasting results was outputted as thematic maps.

  16. Modeling of human movement monitoring using Bluetooth Low Energy technology.

    PubMed

    Mokhtari, G; Zhang, Q; Karunanithi, M

    2015-01-01

    Bluetooth Low Energy (BLE) is a wireless communication technology which can be used to monitor human movements. In this monitoring system, a BLE signal scanner scans signal strength of BLE tags carried by people, to thus infer human movement patterns within its monitoring zone. However to the extent of our knowledge one main aspect of this monitoring system which has not yet been thoroughly investigated in literature is how to build a sound theoretical model, based on tunable BLE communication parameters such as scanning time interval and advertising time interval, to enable the study and design of effective and efficient movement monitoring systems. In this paper, we proposed and developed a statistical model based on Monte-Carlo simulation, which can be utilized to assess impacts of BLE technology parameters in terms of latency and efficiency, on a movement monitoring system, and can thus benefit a more efficient system design.

  17. [Probe into monitoring mechanism of Chinese materia medica resources].

    PubMed

    Zhang, Xiao-Bo; Li, Da-Ning; Guo, Lan-Ping; Lu, Jian-Wei; Sun, Li-Ying; Huang, Lu-Qi

    2013-10-01

    Focusing on the problems of Chinese materia medica resources,and combining with the national Chinese materia medica resources survey, the paper probes into monitoring mechanism of Chinese materia medica resources. The establishment of the monitoring mechanism needs one organization and management agencies to supervise and guide monitoring work, one network system to gather data information, a group of people to perform monitoring work, a system of technical methods to assure monitoring work scientific and practical, a series of achievements and products to figure out the methods for solving problems, a group of monitoring index system to accumulate basic data, and a plenty of funds to keep normal operation of monitoring work.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cho, M; Kim, T; Kang, S

    Purpose: The purpose of this work is to develop a new patient set-up monitoring system using force sensing resistor (FSR) sensors that can confirm pressure of contact surface and evaluate its feasibility. Methods: In this study, we focused on develop the patient set-up monitoring system to compensate for the limitation of existing optical based monitoring system, so the developed system can inform motion in the radiation therapy. The set-up monitoring system was designed consisting of sensor units (FSR sensor), signal conditioning devices (USB cable/interface electronics), a control PC, and a developed analysis software. The sensor unit was made by attachingmore » FSR sensor and dispersing pressure sponge to prevent error which is caused by concentrating specific point. Measured signal from the FSR sensor was sampled to arduino mega 2560 microcontroller, transferred to control PC by using serial communication. The measured data went through normalization process. The normalized data was displayed through the developed graphic user interface (GUI) software. The software was designed to display a single sensor unit intensity (maximum 16 sensors) and display 2D pressure distribution (using 16 sensors) according to the purpose. Results: Changes of pressure value according to motion was confirmed by the developed set-up monitoring system. Very small movement such as little physical change in appearance can be confirmed using a single unit and using 2D pressure distribution. Also, the set-up monitoring system can observe in real time. Conclusion: In this study, we developed the new set-up monitoring system using FSR sensor. Especially, we expect that the new set-up monitoring system is suitable for motion monitoring of blind area that is hard to confirm existing optical system and compensate existing optical based monitoring system. As a further study, an integrated system will be constructed through correlation of existing optical monitoring system. This work was supported by the Industrial R&D program of MOTIE/KEIT. [10048997, Development of the core technology for integrated therapy devices based on real-time MRI guided tumor tracking] and the Mid-career Researcher Program (2014R1A2A1A10050270) through the National Research Foundation of Korea funded by the Ministry of Science, ICT&Future Planning.« less

  19. Personnel reliability impact on petrochemical facilities monitoring system's failure skipping probability

    NASA Astrophysics Data System (ADS)

    Kostyukov, V. N.; Naumenko, A. P.

    2017-08-01

    The paper dwells upon urgent issues of evaluating impact of actions conducted by complex technological systems operators on their safe operation considering application of condition monitoring systems for elements and sub-systems of petrochemical production facilities. The main task for the research is to distinguish factors and criteria of monitoring system properties description, which would allow to evaluate impact of errors made by personnel on operation of real-time condition monitoring and diagnostic systems for machinery of petrochemical facilities, and find and objective criteria for monitoring system class, considering a human factor. On the basis of real-time condition monitoring concepts of sudden failure skipping risk, static and dynamic error, monitoring systems, one may solve a task of evaluation of impact that personnel's qualification has on monitoring system operation in terms of error in personnel or operators' actions while receiving information from monitoring systems and operating a technological system. Operator is considered as a part of the technological system. Although, personnel's behavior is usually a combination of the following parameters: input signal - information perceiving, reaction - decision making, response - decision implementing. Based on several researches on behavior of nuclear powers station operators in USA, Italy and other countries, as well as on researches conducted by Russian scientists, required data on operator's reliability were selected for analysis of operator's behavior at technological facilities diagnostics and monitoring systems. The calculations revealed that for the monitoring system selected as an example, the failure skipping risk for the set values of static (less than 0.01) and dynamic (less than 0.001) errors considering all related factors of data on reliability of information perception, decision-making, and reaction fulfilled is 0.037, in case when all the facilities and error probability are under control - not more than 0.027. In case when only pump and compressor units are under control, the failure skipping risk is not more than 0.022, when the probability of error in operator's action is not more than 0.011. The work output shows that on the basis of the researches results an assessment of operators' reliability can be made in terms of almost any kind of production, but considering only technological capabilities, since operators' psychological and general training considerable vary in different production industries. Using latest technologies of engineering psychology and design of data support systems, situation assessment systems, decision-making and responding system, as well as achievement in condition monitoring in various production industries one can evaluate hazardous condition skipping risk probability considering static, dynamic errors and human factor.

  20. Control system for high power laser drilling workover and completion unit

    DOEpatents

    Zediker, Mark S; Makki, Siamak; Faircloth, Brian O; DeWitt, Ronald A; Allen, Erik C; Underwood, Lance D

    2015-05-12

    A control and monitoring system controls and monitors a high power laser system for performing high power laser operations. The control and monitoring system is configured to perform high power laser operation on, and in, remote and difficult to access locations.

  1. An American knowledge base in England - Alternate implementations of an expert system flight status monitor

    NASA Technical Reports Server (NTRS)

    Butler, G. F.; Graves, A. T.; Disbrow, J. D.; Duke, E. L.

    1989-01-01

    A joint activity between the Dryden Flight Research Facility of the NASA Ames Research Center (Ames-Dryden) and the Royal Aerospace Establishment (RAE) on knowledge-based systems has been agreed. Under the agreement, a flight status monitor knowledge base developed at Ames-Dryden has been implemented using the real-time AI (artificial intelligence) toolkit MUSE, which was developed in the UK. Here, the background to the cooperation is described and the details of the flight status monitor and a prototype MUSE implementation are presented. It is noted that the capabilities of the expert-system flight status monitor to monitor data downlinked from the flight test aircraft and to generate information on the state and health of the system for the test engineers provides increased safety during flight testing of new systems. Furthermore, the expert-system flight status monitor provides the systems engineers with ready access to the large amount of information required to describe a complex aircraft system.

  2. Monitoring, safety systems for LNG and LPG operators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    True, W.R.

    Operators in Korea and Australia have chosen monitoring and control systems in recent contracts for LNG and LPG storage. Korea Gas Corp. (Kogas) has hired Whessoe Varec, Calais, to provide monitoring systems for four LNG storage tanks being built at Kogas` Inchon terminal. For Elgas Ltd., Port Botany, Australia, Whessoe Varec has already shipped a safety valve-shutdown system to a new LPG cavern-storage facility under construction. The paper describes the systems, terminal monitoring, dynamic approach to tank management, and meeting the growing demand for LPG.

  3. Gamma ray spectroscopy monitoring method and apparatus

    DOEpatents

    Stagg, William R; Policke, Timothy A

    2017-05-16

    The present invention relates generally to the field of gamma ray spectroscopy monitoring and a system for accomplishing same to monitor one or more aspects of various isotope production processes. In one embodiment, the present invention relates to a monitoring system, and method of utilizing same, for monitoring one or more aspects of an isotope production process where the monitoring system comprises: (A) at least one sample cell; (B) at least one measuring port; (C) at least one adjustable collimator device; (D) at least one shutter; and (E) at least one high resolution gamma ray spectrometer.

  4. Space Technology for Patient Monitoring

    NASA Technical Reports Server (NTRS)

    1989-01-01

    A contract for the development of an astronaut monitoring system in the early days of the space program provided Mennen Medical, Inc. with a foundation in telemetry that led to the development of a computerized medical electronic system used by hospitals. Mennen was the first company to adopt solid state design in patient monitoring and to offer multipatient telemetry monitoring. Telemetry converts instrument data to electrical signals and relays them to a remote receiver where they are displayed. From a central station, a nurse can monitor several patients. Company products include VISTA systems and Horizon 2000 Monitor.

  5. Connecticut permanent long-term bridge monitoring network, volume 7 : lessons learned for specifications to guide design of structural health monitoring systems.

    DOT National Transportation Integrated Search

    2014-08-01

    This report proposes a set of specifications for bridge structural health monitoring that has resulted from the : experiences gained during the installation and monitoring of six permanent long-term bridge monitoring systems in : Connecticut. As expe...

  6. On-line, continuous monitoring in solar cell and fuel cell manufacturing using spectral reflectance imaging

    DOEpatents

    Sopori, Bhushan; Rupnowski, Przemyslaw; Ulsh, Michael

    2016-01-12

    A monitoring system 100 comprising a material transport system 104 providing for the transportation of a substantially planar material 102, 107 through the monitoring zone 103 of the monitoring system 100. The system 100 also includes a line camera 106 positioned to obtain multiple line images across a width of the material 102, 107 as it is transported through the monitoring zone 103. The system 100 further includes an illumination source 108 providing for the illumination of the material 102, 107 transported through the monitoring zone 103 such that light reflected in a direction normal to the substantially planar surface of the material 102, 107 is detected by the line camera 106. A data processing system 110 is also provided in digital communication with the line camera 106. The data processing system 110 is configured to receive data output from the line camera 106 and further configured to calculate and provide substantially contemporaneous information relating to a quality parameter of the material 102, 107. Also disclosed are methods of monitoring a quality parameter of a material.

  7. The difference of delay time in monitoring system of facial acupressure learning media using bluetooth, wireless and ethernet

    NASA Astrophysics Data System (ADS)

    Agustin, Eny Widhia; Hangga, Arimaz; Fahrian, Muhammad Iqbal; Azhari, Anis Fikri

    2018-03-01

    The implementation of monitoring system in the facial acupressure learning media could increase the students' proficiency. However the common learning media still has not implemented a monitoring system in their learning process. This research was conducted to implement monitoring system in the mannequin head prototype as a learning media of facial acupressure using Bluetooth, wireless and Ethernet. The results of the implementation of monitoring system in the prototype showed that there were differences in the delay time between Bluetooth and wireless or Ethernet. The results data showed no difference in the average delay time between the use of Bluetooth with wireless and the use of Bluetooth with Ethernet in monitoring system of facial acupressure learning media. From all the facial acupressure points, the forehead facial acupressure point has the longest delay time of 11.93 seconds. The average delay time in all 3 class rooms was 1.96 seconds therefore the use of Bluetooth, wireless and Ethernet is highly recommended in the monitoring system of facial acupressure.

  8. 40 CFR 63.11221 - How do I monitor and collect data to demonstrate continuous compliance?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... malfunctions or out-of-control periods, or required monitoring system quality assurance or control activities... collect data according to this section. (b) You must operate the monitoring system and collect data at all required intervals at all times the affected source is operating except for periods of monitoring system...

  9. 40 CFR 63.11221 - How do I monitor and collect data to demonstrate continuous compliance?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... malfunctions or out-of-control periods, or required monitoring system quality assurance or control activities... collect data according to this section. (b) You must operate the monitoring system and collect data at all required intervals at all times the affected source is operating except for periods of monitoring system...

  10. 40 CFR 75.72 - Determination of NOX mass emissions for common stack and multiple stack configurations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the hourly stack flow rate (in scfh). Only one methodology for determining NOX mass emissions shall be...-diluent continuous emissions monitoring system and a flow monitoring system in the common stack, record... maintain a flow monitoring system and diluent monitor in the duct to the common stack from each unit; or...

  11. 40 CFR 60.4345 - What are the requirements for the continuous emission monitoring system equipment, if I choose to...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... continuous emission monitoring system equipment, if I choose to use this option? 60.4345 Section 60.4345... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Stationary Combustion Turbines Monitoring § 60.4345 What are the requirements for the continuous emission monitoring system equipment, if I...

  12. 40 CFR 60.1280 - What must I do if any of my continuous emission monitoring systems are temporarily unavailable to...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... emission monitoring systems are temporarily unavailable to meet the data collection requirements? 60.1280... Modification or Reconstruction is Commenced After June 6, 2001 Continuous Emission Monitoring § 60.1280 What must I do if any of my continuous emission monitoring systems are temporarily unavailable to meet the...

  13. 40 CFR 60.4345 - What are the requirements for the continuous emission monitoring system equipment, if I choose to...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... continuous emission monitoring system equipment, if I choose to use this option? 60.4345 Section 60.4345... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Stationary Combustion Turbines Monitoring § 60.4345 What are the requirements for the continuous emission monitoring system equipment, if I...

  14. 40 CFR 60.1280 - What must I do if any of my continuous emission monitoring systems are temporarily unavailable to...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... emission monitoring systems are temporarily unavailable to meet the data collection requirements? 60.1280... Modification or Reconstruction is Commenced After June 6, 2001 Continuous Emission Monitoring § 60.1280 What must I do if any of my continuous emission monitoring systems are temporarily unavailable to meet the...

  15. Automated acquisition system for routine, noninvasive monitoring of physiological data.

    PubMed

    Ogawa, M; Tamura, T; Togawa, T

    1998-01-01

    A fully automated, noninvasive data-acquisition system was developed to permit long-term measurement of physiological functions at home, without disturbing subjects' normal routines. The system consists of unconstrained monitors built into furnishings and structures in a home environment. An electrocardiographic (ECG) monitor in the bathtub measures heart function during bathing, a temperature monitor in the bed measures body temperature, and a weight monitor built into the toilet serves as a scale to record weight. All three monitors are connected to one computer and function with data-acquisition programs and a data format rule. The unconstrained physiological parameter monitors and fully automated measurement procedures collect data noninvasively without the subject's awareness. The system was tested for 1 week by a healthy male subject, aged 28, in laboratory-based facilities.

  16. Engineering monitoring expert system's developer

    NASA Technical Reports Server (NTRS)

    Lo, Ching F.

    1991-01-01

    This research project is designed to apply artificial intelligence technology including expert systems, dynamic interface of neural networks, and hypertext to construct an expert system developer. The developer environment is specifically suited to building expert systems which monitor the performance of ground support equipment for propulsion systems and testing facilities. The expert system developer, through the use of a graphics interface and a rule network, will be transparent to the user during rule constructing and data scanning of the knowledge base. The project will result in a software system that allows its user to build specific monitoring type expert systems which monitor various equipments used for propulsion systems or ground testing facilities and accrues system performance information in a dynamic knowledge base.

  17. A real time status monitor for transistor bank driver power limit resistor in boost injection kicker power supply

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mi, J.; Tan, Y.; Zhang, W.

    2011-03-28

    For years suffering of Booster Injection Kicker transistor bank driver regulator troubleshooting, a new real time monitor system has been developed. A simple and floating circuit has been designed and tested. This circuit monitor system can monitor the driver regulator power limit resistor status in real time and warn machine operator if the power limit resistor changes values. This paper will mainly introduce the power supply and the new designed monitoring system. This real time resistor monitor circuit shows a useful method to monitor some critical parts in the booster pulse power supply. After two years accelerator operation, it showsmore » that this monitor works well. Previously, we spent a lot of time in booster machine trouble shooting. We will reinstall all 4 PCB into Euro Card Standard Chassis when the power supply system will be updated.« less

  18. Software design of a remote real-time ECG monitoring system

    NASA Astrophysics Data System (ADS)

    Yu, Chengbo; Tao, Hongyan

    2005-12-01

    Heart disease is one of the main diseases that threaten the health and lives of human beings. At present, the normal remote ECG monitoring system has the disadvantages of a short testing distance and limitation of monitoring lines. Because of accident and paroxysmal disease, ECG monitoring has extended from the hospital to the family. Therefore, remote ECG monitoring through the Internet has the actual value and significance. The principle and design method of software of the remote dynamic ECG monitor was presented and discussed. The monitoring software is programmed with Delphi software based on client-sever interactive mode. The application program of the system, which makes use of multithreading technology, is shown to perform in an excellent manner. The program includes remote link users and ECG processing, i.e. ECG data's receiving, real-time displaying, recording and replaying. The system can connect many clients simultaneously and perform real-time monitoring to patients.

  19. A Fully Redundant On-Line Mass Spectrometer System Used to Monitor Cryogenic Fuel Leaks on the Space Shuttle

    NASA Technical Reports Server (NTRS)

    Griffin, Timothy P.; Naylor, Guy R.; Haskell, William D.; Breznik, Greg S.; Mizell, Carolyn A.; Helms, William R.; Steinrock, T. (Technical Monitor)

    2001-01-01

    An on-line gas monitoring system was developed to replace the older systems used to monitor for cryogenic leaks on the Space Shuttles before launch. The system uses a mass spectrometer to monitor multiple locations in the process, which allows the system to monitor all gas constituents of interest in a nearly simultaneous manner. The system is fully redundant and meets all requirements for ground support equipment (GSE). This includes ruggedness to withstand launch on the Mobile Launcher Platform (MLP), ease of operation, and minimal operator intervention. The system can be fully automated so that an operator is notified when an unusual situation or fault is detected. User inputs are through personal computer using mouse and keyboard commands. The graphical user interface is very intuitive and easy to operate. The system has successfully supported four launches to date. It is currently being permanently installed as the primary system monitoring the Space Shuttles during ground processing and launch operations. Time and cost savings will be substantial over the current systems when it is fully implemented in the field. Tests were performed to demonstrate the performance of the system. Low limits-of-detection coupled with small drift make the system a major enhancement over the current systems. Though this system is currently optimized for detecting cryogenic leaks, many other gas constituents could be monitored using the Hazardous Gas Detection System (HGDS) 2000.

  20. Automated Intelligent Monitoring and the Controlling Software System for Solar Panels

    NASA Astrophysics Data System (ADS)

    Nalamwar, H. S.; Ivanov, M. A.; Baidali, S. A.

    2017-01-01

    The inspection of the solar panels on a periodic basis is important to improve longevity and ensure performance of the solar system. To get the most solar potential of the photovoltaic (PV) system is possible through an intelligent monitoring & controlling system. The monitoring & controlling system has rapidly increased its popularity because of its user-friendly graphical interface for data acquisition, monitoring, controlling and measurements. In order to monitor the performance of the system especially for renewable energy source application such as solar photovoltaic (PV), data-acquisition systems had been used to collect all the data regarding the installed system. In this paper the development of a smart automated monitoring & controlling system for the solar panel is described, the core idea is based on IoT (the Internet of Things). The measurements of data are made using sensors, block management data acquisition modules, and a software system. Then, all the real-time data collection of the electrical output parameters of the PV plant such as voltage, current and generated electricity is displayed and stored in the block management. The proposed system is smart enough to make suggestions if the panel is not working properly, to display errors, to remind about maintenance of the system through email or SMS, and to rotate panels according to a sun position using the Ephemeral table that stored in the system. The advantages of the system are the performance of the solar panel system which can be monitored and analyzed.

  1. Continuous emission monitoring and accounting automated systems at an HPP

    NASA Astrophysics Data System (ADS)

    Roslyakov, P. V.; Ionkin, I. L.; Kondrateva, O. E.; Borovkova, A. M.; Seregin, V. A.; Morozov, I. V.

    2015-03-01

    Environmental and industrial emission monitoring at HPP's is a very urgent task today. Industrial monitoring assumes monitoring of emissions of harmful pollutants and optimization of fuel combustion technological processes at HPP's. Environmental monitoring is a system to assess ambient air quality with respect to a number of separate sources of harmful substances in pollution of atmospheric air of the area. Works on creating an industrial monitoring system are carried out at the National Research University Moscow Power Engineering Institute (MPEI) on the basis of the MPEI combined heat and power plant, and environmental monitoring stations are installed in Lefortovo raion, where the CHPP is located.

  2. Performance Monitoring of Distributed Data Processing Systems

    NASA Technical Reports Server (NTRS)

    Ojha, Anand K.

    2000-01-01

    Test and checkout systems are essential components in ensuring safety and reliability of aircraft and related systems for space missions. A variety of systems, developed over several years, are in use at the NASA/KSC. Many of these systems are configured as distributed data processing systems with the functionality spread over several multiprocessor nodes interconnected through networks. To be cost-effective, a system should take the least amount of resource and perform a given testing task in the least amount of time. There are two aspects of performance evaluation: monitoring and benchmarking. While monitoring is valuable to system administrators in operating and maintaining, benchmarking is important in designing and upgrading computer-based systems. These two aspects of performance evaluation are the foci of this project. This paper first discusses various issues related to software, hardware, and hybrid performance monitoring as applicable to distributed systems, and specifically to the TCMS (Test Control and Monitoring System). Next, a comparison of several probing instructions are made to show that the hybrid monitoring technique developed by the NIST (National Institutes for Standards and Technology) is the least intrusive and takes only one-fourth of the time taken by software monitoring probes. In the rest of the paper, issues related to benchmarking a distributed system have been discussed and finally a prescription for developing a micro-benchmark for the TCMS has been provided.

  3. Research of hydroelectric generating set low-frequency vibration monitoring system based on optical fiber sensing

    NASA Astrophysics Data System (ADS)

    Min, Li; Zhang, Xiaolei; Zhang, Faxiang; Sun, Zhihui; Li, ShuJuan; Wang, Meng; Wang, Chang

    2017-10-01

    In order to satisfy hydroelectric generating set low-frequency vibration monitoring, the design of Passive low-frequency vibration monitoring system based on Optical fiber sensing in this paper. The hardware of the system adopts the passive optical fiber grating sensor and unbalanced-Michelson interferometer. The software system is used to programming by Labview software and finishing the control of system. The experiment show that this system has good performance on the standard vibration testing-platform and it meets system requirements. The frequency of the monitoring system can be as low as 0.2Hz and the resolution is 0.01Hz.

  4. A Hydrogen Leak Detection System for Aerospace and Commercial Applications

    NASA Technical Reports Server (NTRS)

    Hunter, Gary W.; Makel, D. B.; Jansa, E. D.; Patterson, G.; Cova, P. J.; Liu, C. C.; Wu, Q. H.; Powers, W. T.

    1995-01-01

    Leaks on the space shuttle while on the launch pad have generated interest in hydrogen leak monitoring technology. Microfabricated hydrogen sensors are being fabricated at Case Western Reserve University (CWRU) and tested at NASA Lewis Research Center (LeRC). These sensors have been integrated into hardware and software designed by Aerojet. This complete system allows for multipoint leak monitoring designed to provide leak source and magnitude information in real time. The monitoring system processes data from the hydrogen sensors and presents the operator with a visual indication of the leak location and magnitude. Although the leak monitoring system was designed for hydrogen propulsion systems, the possible applications of this monitoring system are wide ranged. This system is in operation in an automotive application which requires high sensitivity to hydrogen.

  5. 105KE Basin Area Radiation Monitor System (ARMS) Acceptance Test Procedure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    KINKEL, C.C.

    1999-12-14

    This procedure is intended for the Area Radiation Monitoring System, ARMS, that is replacing the existing Programmable Input-Output Processing System, PIOPS, radiation monitoring system in the 105KE basin. The new system will be referred to as the 105KE ARMS, 105KE Area Radiation Monitoring System. This ATP will ensure calibration integrity of the 105KE radiation detector loops. Also, this ATP will test and document the display, printing, alarm output, alarm acknowledgement, upscale check, and security functions. This ATP test is to be performed after completion of the 105KE ARMS installation. The alarm outputs of the 105KE ARMS will be connected tomore » the basin detector alarms, basin annunciator system, and security Alarm Monitoring System, AMS, located in the 200 area Central Alarm Station (CAS).« less

  6. Arduino Based Infant Monitoring System

    NASA Astrophysics Data System (ADS)

    Farhanah Mohamad Ishak, Daing Noor; Jamil, Muhammad Mahadi Abdul; Ambar, Radzi

    2017-08-01

    This paper proposes a system for monitoring infant in an incubator and records the relevant data into a computer. The data recorded by the system can be further referred by the neonatal intensive care unit (NICU) personnel for diagnostic or research purposes. The study focuses on designing the monitoring system that consists of an incubator equipped with humidity sensor to measure the humidity level, and a pulse sensor that can be attached on an infant placed inside the incubator to monitor infant’s heart pulse. The measurement results which are the pulse rate and humidity level are sent to the PC via Arduino microcontroller. The advantage of this system will be that in the future, it may also enable doctors to closely monitor the infant condition through local area network and internet. This work is aimed as an example of an application that contributes towards remote tele-health monitoring system.

  7. A Mobile Multi-Agent Information System for Ubiquitous Fetal Monitoring

    PubMed Central

    Su, Chuan-Jun; Chu, Ta-Wei

    2014-01-01

    Electronic fetal monitoring (EFM) systems integrate many previously separate clinical activities related to fetal monitoring. Promoting the use of ubiquitous fetal monitoring services with real time status assessments requires a robust information platform equipped with an automatic diagnosis engine. This paper presents the design and development of a mobile multi-agent platform-based open information systems (IMAIS) with an automated diagnosis engine to support intensive and distributed ubiquitous fetal monitoring. The automatic diagnosis engine that we developed is capable of analyzing data in both traditional paper-based and digital formats. Issues related to interoperability, scalability, and openness in heterogeneous e-health environments are addressed through the adoption of a FIPA2000 standard compliant agent development platform—the Java Agent Development Environment (JADE). Integrating the IMAIS with light-weight, portable fetal monitor devices allows for continuous long-term monitoring without interfering with a patient’s everyday activities and without restricting her mobility. The system architecture can be also applied to vast monitoring scenarios such as elder care and vital sign monitoring. PMID:24452256

  8. INDUCTIVE SYSTEM HEALTH MONITORING WITH STATISTICAL METRICS

    NASA Technical Reports Server (NTRS)

    Iverson, David L.

    2005-01-01

    Model-based reasoning is a powerful method for performing system monitoring and diagnosis. Building models for model-based reasoning is often a difficult and time consuming process. The Inductive Monitoring System (IMS) software was developed to provide a technique to automatically produce health monitoring knowledge bases for systems that are either difficult to model (simulate) with a computer or which require computer models that are too complex to use for real time monitoring. IMS processes nominal data sets collected either directly from the system or from simulations to build a knowledge base that can be used to detect anomalous behavior in the system. Machine learning and data mining techniques are used to characterize typical system behavior by extracting general classes of nominal data from archived data sets. In particular, a clustering algorithm forms groups of nominal values for sets of related parameters. This establishes constraints on those parameter values that should hold during nominal operation. During monitoring, IMS provides a statistically weighted measure of the deviation of current system behavior from the established normal baseline. If the deviation increases beyond the expected level, an anomaly is suspected, prompting further investigation by an operator or automated system. IMS has shown potential to be an effective, low cost technique to produce system monitoring capability for a variety of applications. We describe the training and system health monitoring techniques of IMS. We also present the application of IMS to a data set from the Space Shuttle Columbia STS-107 flight. IMS was able to detect an anomaly in the launch telemetry shortly after a foam impact damaged Columbia's thermal protection system.

  9. Design and implementation of temperature and humidity monitoring system for poultry farm

    NASA Astrophysics Data System (ADS)

    Purnomo, Hindriyanto Dwi; Somya, Ramos; Fibriani, Charitas; Purwoko, Angga; Sadiyah, Ulfa

    2016-10-01

    Automatic monitoring system gains significant interest in poultry industry due to the need of consistent environment condition. Appropriate environment increase the feed conversion ratio as well as birds productivity. This will increase the competitiveness of the poultry industry. In this research, a temperature and humidity monitoring system is proposed to observer the temperature and relative humidity of a poultry house. The system is intended to be applied in the poultry industry with partnership schema. The proposed system is equipped with CCTV for visual monitoring. The measured temperature and humidity implement wireless sensor network technology. The experiment results reveals that proposed system have the potential to increase the effectiveness of monitoring of poultry house in poultry industry with partnership schema.

  10. Radio Frequency Identification (RFID) and communication technologies for solid waste bin and truck monitoring system.

    PubMed

    Hannan, M A; Arebey, Maher; Begum, R A; Basri, Hassan

    2011-12-01

    This paper deals with a system of integration of Radio Frequency Identification (RFID) and communication technologies for solid waste bin and truck monitoring system. RFID, GPS, GPRS and GIS along with camera technologies have been integrated and developed the bin and truck intelligent monitoring system. A new kind of integrated theoretical framework, hardware architecture and interface algorithm has been introduced between the technologies for the successful implementation of the proposed system. In this system, bin and truck database have been developed such a way that the information of bin and truck ID, date and time of waste collection, bin status, amount of waste and bin and truck GPS coordinates etc. are complied and stored for monitoring and management activities. The results showed that the real-time image processing, histogram analysis, waste estimation and other bin information have been displayed in the GUI of the monitoring system. The real-time test and experimental results showed that the performance of the developed system was stable and satisfied the monitoring system with high practicability and validity. Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. 48 CFR 342.7001 - Contract monitoring responsibilities.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 4 2013-10-01 2013-10-01 false Contract monitoring responsibilities. 342.7001 Section 342.7001 Federal Acquisition Regulations System HEALTH AND HUMAN SERVICES CONTRACT MANAGEMENT CONTRACT ADMINISTRATION Contract Monitoring 342.7001 Contract monitoring...

  12. 48 CFR 342.7001 - Contract monitoring responsibilities.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 4 2011-10-01 2011-10-01 false Contract monitoring responsibilities. 342.7001 Section 342.7001 Federal Acquisition Regulations System HEALTH AND HUMAN SERVICES CONTRACT MANAGEMENT CONTRACT ADMINISTRATION Contract Monitoring 342.7001 Contract monitoring...

  13. 48 CFR 342.7001 - Contract monitoring responsibilities.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 4 2012-10-01 2012-10-01 false Contract monitoring responsibilities. 342.7001 Section 342.7001 Federal Acquisition Regulations System HEALTH AND HUMAN SERVICES CONTRACT MANAGEMENT CONTRACT ADMINISTRATION Contract Monitoring 342.7001 Contract monitoring...

  14. 48 CFR 342.7001 - Contract monitoring responsibilities.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 4 2014-10-01 2014-10-01 false Contract monitoring responsibilities. 342.7001 Section 342.7001 Federal Acquisition Regulations System HEALTH AND HUMAN SERVICES CONTRACT MANAGEMENT CONTRACT ADMINISTRATION Contract Monitoring 342.7001 Contract monitoring...

  15. Simultaneous Authentication and Certification of Arms-Control Measurement Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MacArthur, Duncan W.; Hauck, Danielle K.; Thron, Jonathan L.

    2012-07-09

    Most arms-control-treaty-monitoring scenarios involve a host party that makes a declaration regarding its nuclear material or items and a monitoring party that verifies that declaration. A verification system developed for such a use needs to be trusted by both parties. The first concern, primarily from the host party's point of view, is that any sensitive information that is collected must be protected without interfering in the efficient operation of the facility being monitored. This concern is addressed in what can be termed a 'certification' process. The second concern, of particular interest to the monitoring party, is that it must bemore » possible to confirm the veracity of both the measurement system and the data produced by this measurement system. The monitoring party addresses these issues during an 'authentication' process. Addressing either one of these concerns independently is relatively straightforward. However, it is more difficult to simultaneously satisfy host party certification concerns and monitoring party authentication concerns. Typically, both parties will want the final access to the measurement system. We will describe an alternative approach that allows both parties to gain confidence simultaneously. This approach starts with (1) joint development of the measurement system followed by (2) host certification of several copies of the system and (3) random selection by the inspecting party of one copy to be use during the monitoring visit and one (or more) copy(s) to be returned to the inspecting party's facilities for (4) further hardware authentication; any remaining copies are stored under joint seal for use as spares. Following this process, the parties will jointly (5) perform functional testing on the selected measurement system and then (6) use this system during the monitoring visit. Steps (1) and (2) assure the host party as to the certification of whichever system is eventually used in the monitoring visit. Steps (1), (3), (4), and (5) increase the monitoring party's confidence in the authentication of the measurement system.« less

  16. 47 CFR 73.68 - Sampling systems for antenna monitors.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 4 2014-10-01 2014-10-01 false Sampling systems for antenna monitors. 73.68... RADIO BROADCAST SERVICES AM Broadcast Stations § 73.68 Sampling systems for antenna monitors. (a) Each AM station permittee authorized to construct a new directional antenna system which will be subject...

  17. 47 CFR 73.68 - Sampling systems for antenna monitors.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 4 2013-10-01 2013-10-01 false Sampling systems for antenna monitors. 73.68... RADIO BROADCAST SERVICES AM Broadcast Stations § 73.68 Sampling systems for antenna monitors. (a) Each AM station permittee authorized to construct a new directional antenna system which will be subject...

  18. 47 CFR 73.68 - Sampling systems for antenna monitors.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Sampling systems for antenna monitors. 73.68... RADIO BROADCAST SERVICES AM Broadcast Stations § 73.68 Sampling systems for antenna monitors. (a) Each AM station permittee authorized to construct a new directional antenna system which will be subject...

  19. 47 CFR 73.68 - Sampling systems for antenna monitors.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 4 2012-10-01 2012-10-01 false Sampling systems for antenna monitors. 73.68... RADIO BROADCAST SERVICES AM Broadcast Stations § 73.68 Sampling systems for antenna monitors. (a) Each AM station permittee authorized to construct a new directional antenna system which will be subject...

  20. 47 CFR 73.68 - Sampling systems for antenna monitors.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 4 2011-10-01 2011-10-01 false Sampling systems for antenna monitors. 73.68... RADIO BROADCAST SERVICES AM Broadcast Stations § 73.68 Sampling systems for antenna monitors. (a) Each AM station permittee authorized to construct a new directional antenna system which will be subject...

  1. Monitoring components of GypsES

    Treesearch

    Lukas P. Schaub; F. William Ravlin; Jesse A. Logan; Shelby J. Fleischer

    1991-01-01

    The manager needs tools for assistance in planning and interpreting monitoring systems. We are building a system that designs sampling programs by interpreting data about Gypsy Moth, stand condition and management objectives. The system prioritizes areas within the management unit within budgetary constraints and defines the areas to be monitored. The system proposes...

  2. 40 CFR 60.2939 - What continuous emission monitoring systems must I install?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... systems must I install? 60.2939 Section 60.2939 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 60.2939 What continuous emission monitoring systems must I install? (a) You must install, calibrate, maintain, and operate continuous emission monitoring systems for carbon monoxide and for oxygen. You must...

  3. 40 CFR 60.2939 - What continuous emission monitoring systems must I install?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... systems must I install? 60.2939 Section 60.2939 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 60.2939 What continuous emission monitoring systems must I install? (a) You must install, calibrate, maintain, and operate continuous emission monitoring systems for carbon monoxide and for oxygen. You must...

  4. 75 FR 62098 - Proposed Information Collection; Comment Request; Expanded Vessel Monitoring System Requirement...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-07

    ... Collection; Comment Request; Expanded Vessel Monitoring System Requirement in the Pacific Coast Groundfish... and use a vessel monitoring system (VMS) that automatically sends hourly position reports. Exemptions... declaration reporting system are not expected to change the public reporting burden. II. Method of Collection...

  5. Synergy of Earth Observation and In-Situ Monitoring Data for Flood Hazard Early Warning System

    NASA Astrophysics Data System (ADS)

    Brodsky, Lukas; Kodesova, Radka; Spazierova, Katerina

    2010-12-01

    In this study, we demonstrate synergy of EO and in-situ monitoring data for early warning flood hazard system in the Czech Republic developed within ESA PECS project FLOREO. The development of the demonstration system is oriented to support existing monitoring activities, especially snow melt and surface water runoff contributing to flooding events. The system consists of two main parts accordingly, the first is snow cover and snow melt monitoring driven mainly by EO data and the other is surface water runoff modeling and monitoring driven by synergy of in-situ and EO data.

  6. 40 CFR 141.26 - Monitoring frequency and compliance requirements for radionuclides in community water systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... For the purposes of monitoring for gross alpha particle activity, radium-226, radium-228, uranium, and... monitoring: Systems must conduct initial monitoring for gross alpha particle activity, radium-226, radium-228...) For gross alpha particle activity, uranium, radium-226, and radium-228 monitoring, the State may waive...

  7. Acoustic emission monitoring of composite containment systems

    NASA Astrophysics Data System (ADS)

    Maguire, John R.

    2011-07-01

    This paper considers two different types of composite containment system, and two different types of acoustic emission (AE) monitoring approach. The first system is a composite reinforced pressure vessel (CRPV) which is monitored both during construction and in-service using a broadband modal acoustic emission (MAE) technique. The second system is a membrane cargo containment system which is monitored using both a global as well as a local AE technique. For the CRPV, the damage assessment is concerned mainly with the integrity of the composite outer layer at the construction stage, and possible fatigue cracking of the inner steel liner at the in-service stage. For the membrane tank, the damage assessment is concerned with locating and quantifying any abnormal porosities that might develop in-service. By comparing and contrasting the different types of structural system and different monitoring approaches inferences are drawn as to what role AE monitoring could take in the damage assessment of other types of composite containment system. (Detailed technical data have not been included, due to client confidentiality constraints.)

  8. Research and design of smart grid monitoring control via terminal based on iOS system

    NASA Astrophysics Data System (ADS)

    Fu, Wei; Gong, Li; Chen, Heli; Pan, Guangji

    2017-06-01

    Aiming at a series of problems existing in current smart grid monitoring Control Terminal, such as high costs, poor portability, simple monitoring system, poor software extensions, low system reliability when transmitting information, single man-machine interface, poor security, etc., smart grid remote monitoring system based on the iOS system has been designed. The system interacts with smart grid server so that it can acquire grid data through WiFi/3G/4G networks, and monitor each grid line running status, as well as power plant equipment operating conditions. When it occurs an exception in the power plant, incident information can be sent to the user iOS terminal equipment timely, which will provide troubleshooting information to help the grid staff to make the right decisions in a timely manner, to avoid further accidents. Field tests have shown the system realizes the integrated grid monitoring functions, low maintenance cost, friendly interface, high security and reliability, and it possesses certain applicable value.

  9. Design of smart neonatal health monitoring system using SMCC

    PubMed Central

    Mukherjee, Anwesha; Bhakta, Ishita

    2016-01-01

    Automated health monitoring and alert system development is a demanding research area today. Most of the currently available monitoring and controlling medical devices are wired which limits freeness of working environment. Wireless sensor network (WSN) is a better alternative in such an environment. Neonatal intensive care unit is used to take care of sick and premature neonates. Hypothermia is an independent risk factor for neonatal mortality and morbidity. To prevent it an automated monitoring system is required. In this Letter, an automated neonatal health monitoring system is designed using sensor mobile cloud computing (SMCC). SMCC is based on WSN and MCC. In the authors’ system temperature sensor, acceleration sensor and heart rate measurement sensor are used to monitor body temperature, acceleration due to body movement and heart rate of neonates. The sensor data are stored inside the cloud. The health person continuously monitors and accesses these data through the mobile device using an Android Application for neonatal monitoring. When an abnormal situation arises, an alert is generated in the mobile device of the health person. By alerting health professional using such an automated system, early care is provided to the affected babies and the probability of recovery is increased. PMID:28261491

  10. Remote maintenance monitoring system

    NASA Technical Reports Server (NTRS)

    Simpkins, Lorenz G. (Inventor); Owens, Richard C. (Inventor); Rochette, Donn A. (Inventor)

    1992-01-01

    A remote maintenance monitoring system retrofits to a given hardware device with a sensor implant which gathers and captures failure data from the hardware device, without interfering with its operation. Failure data is continuously obtained from predetermined critical points within the hardware device, and is analyzed with a diagnostic expert system, which isolates failure origin to a particular component within the hardware device. For example, monitoring of a computer-based device may include monitoring of parity error data therefrom, as well as monitoring power supply fluctuations therein, so that parity error and power supply anomaly data may be used to trace the failure origin to a particular plane or power supply within the computer-based device. A plurality of sensor implants may be rerofit to corresponding plural devices comprising a distributed large-scale system. Transparent interface of the sensors to the devices precludes operative interference with the distributed network. Retrofit capability of the sensors permits monitoring of even older devices having no built-in testing technology. Continuous real time monitoring of a distributed network of such devices, coupled with diagnostic expert system analysis thereof, permits capture and analysis of even intermittent failures, thereby facilitating maintenance of the monitored large-scale system.

  11. Design of smart neonatal health monitoring system using SMCC.

    PubMed

    De, Debashis; Mukherjee, Anwesha; Sau, Arkaprabha; Bhakta, Ishita

    2017-02-01

    Automated health monitoring and alert system development is a demanding research area today. Most of the currently available monitoring and controlling medical devices are wired which limits freeness of working environment. Wireless sensor network (WSN) is a better alternative in such an environment. Neonatal intensive care unit is used to take care of sick and premature neonates. Hypothermia is an independent risk factor for neonatal mortality and morbidity. To prevent it an automated monitoring system is required. In this Letter, an automated neonatal health monitoring system is designed using sensor mobile cloud computing (SMCC). SMCC is based on WSN and MCC. In the authors' system temperature sensor, acceleration sensor and heart rate measurement sensor are used to monitor body temperature, acceleration due to body movement and heart rate of neonates. The sensor data are stored inside the cloud. The health person continuously monitors and accesses these data through the mobile device using an Android Application for neonatal monitoring. When an abnormal situation arises, an alert is generated in the mobile device of the health person. By alerting health professional using such an automated system, early care is provided to the affected babies and the probability of recovery is increased.

  12. Performance Monitoring Applied to System Supervision

    PubMed Central

    Somon, Bertille; Campagne, Aurélie; Delorme, Arnaud; Berberian, Bruno

    2017-01-01

    Nowadays, automation is present in every aspect of our daily life and has some benefits. Nonetheless, empirical data suggest that traditional automation has many negative performance and safety consequences as it changed task performers into task supervisors. In this context, we propose to use recent insights into the anatomical and neurophysiological substrates of action monitoring in humans, to help further characterize performance monitoring during system supervision. Error monitoring is critical for humans to learn from the consequences of their actions. A wide variety of studies have shown that the error monitoring system is involved not only in our own errors, but also in the errors of others. We hypothesize that the neurobiological correlates of the self-performance monitoring activity can be applied to system supervision. At a larger scale, a better understanding of system supervision may allow its negative effects to be anticipated or even countered. This review is divided into three main parts. First, we assess the neurophysiological correlates of self-performance monitoring and their characteristics during error execution. Then, we extend these results to include performance monitoring and error observation of others or of systems. Finally, we provide further directions in the study of system supervision and assess the limits preventing us from studying a well-known phenomenon: the Out-Of-the-Loop (OOL) performance problem. PMID:28744209

  13. Nashville Solar-Water-Heater Demonstration Project. Monitoring-data analysis

    NASA Astrophysics Data System (ADS)

    1982-03-01

    Field monitoring data which were collected for the Nashville Solar Water Heater Demonstration Project from September through November of 1981 are presented. Twenty-six solar domestic water heaters were monitored during September, 35 during October, and 37 during November. Homeowners were audited to assure adequate solar access, and each selected a solar water heating system from an approved list. Two tank and one tank systems are included. The monitoring sample technique and monitoring system are described. Data are analyzed by computer to produce daily and monthly total summaries for each site. The performance of each site was assessed to compare total energy saved by the solar system, solar system savings percentage, and the energy multiplier.

  14. Potential of plant genetic systems for monitoring and screening mutagens

    PubMed Central

    Nilan, R. A.

    1978-01-01

    Plants have too long been ignored as useful screening and monitoring systems of environmental mutagens. However, there are about a dozen reliable, some even unique, plant genetic systems that can increase the scope and effectiveness of chemical and physical mutagen screening and monitoring procedures. Some of these should be included in the Tier II tests. Moreover, plants are the only systems now in use as monitors of genetic effects caused by polluted atmosphere and water and by pesticides. There are several major advantages of the plant test systems which relate to their reproductive nature, easy culture and growth habits that should be considered in mutagen screening and monitoring. In addition to these advantages, the major plant test systems exhibit numerous genetic and chromosome changes for determining the effects of mutagens. Some of these have not yet been detected in other nonmammalian and mammalian test systems, but probably occur in the human organism. Plants have played major roles in various aspects of mutagenesis research, primarily in mutagen screening (detection and verification of mutagenic activity), mutagen monitoring, and determining mutagen effects and mechanisms of mutagen action. They have played lesser roles in quantification of mutagenic activity and understanding the nature of induced mutations. Mutagen monitoring with plants, especially in situ on land or in water, will help determine potential genetic hazards of air and water pollutants and protect the genetic purity of crop plants and the purity of the food supply. The Tradescantia stamen-hair system is used in a mobile laboratory for determining the genetic effects of industrial and automobile pollution in a number of sites in the U.S.A. The fern is employed for monitoring genetic effects of water pollution in the Eastern states. The maize pollen system and certain weeds have monitored genetic effects of pesticides. Several other systems that have considerable value and should be developed and more widely used in mutagen monitoring and screening, especially for in situ monitoring, are discussed. Emphasis is placed on pollen systems in which changes in pollen structure, chemistry, and chromosomes can be scored for monitoring; and screening systems which can record low levels of genetic effects as well as provide information on the nature of induced mutations. The value of plant systems for monitoring and screening mutagens can be improved by: greater knowledge of plant cell processes at the molecular and ultrastructural levels; relating these processes to mutagen effects and plant cell responses; improving current systems for increased sensitivity, ease of detecting genetic and chromosome changes, recording of data (including automation), and for extending the range of genetic and chromosome end points; and designing and developing new systems with the aid of previous and current botanical and genetic knowledge. PMID:367768

  15. Low-cost measurement and monitoring system for cryogenic applications

    NASA Astrophysics Data System (ADS)

    Tubío Araújo, Óscar; Hernández Suárez, Elvio; Gracia Temich, Félix

    2016-07-01

    Cryostats are closed chambers that hinder the monitoring of materials, structures or systems installed therein. This paper presents a webcam-based measurement and monitoring system, which can operate under vacuum and cryogenic conditions to be mainly used in astrophysical applications. The system can be configured in two different assemblies: wide field that can be used for mechanism monitoring and narrow field, especially useful in cryogenic precision measurements with a resolution up to 4 microns/pixel.

  16. Hydrological Monitoring System Design and Implementation Based on IOT

    NASA Astrophysics Data System (ADS)

    Han, Kun; Zhang, Dacheng; Bo, Jingyi; Zhang, Zhiguang

    In this article, an embedded system development platform based on GSM communication is proposed. Through its application in hydrology monitoring management, the author makes discussion about communication reliability and lightning protection, suggests detail solutions, and also analyzes design and realization of upper computer software. Finally, communication program is given. Hydrology monitoring system from wireless communication network is a typical practical application of embedded system, which has realized intelligence, modernization, high-efficiency and networking of hydrology monitoring management.

  17. Formal verification of medical monitoring software using Z language: a representative sample.

    PubMed

    Babamir, Seyed Morteza; Borhani, Mehdi

    2012-08-01

    Medical monitoring systems are useful aids assisting physicians in keeping patients under constant surveillance; however, taking sound decision by the systems is a physician concern. As a result, verification of the systems behavior in monitoring patients is a matter of significant. The patient monitoring is undertaken by software in modern medical systems; so, software verification of modern medial systems have been noticed. Such verification can be achieved by the Formal Languages having mathematical foundations. Among others, the Z language is a suitable formal language has been used to formal verification of systems. This study aims to present a constructive method to verify a representative sample of a medical system by which the system is visually specified and formally verified against patient constraints stated in Z Language. Exploiting our past experience in formal modeling Continuous Infusion Insulin Pump (CIIP), we think of the CIIP system as a representative sample of medical systems in proposing our present study. The system is responsible for monitoring diabetic's blood sugar.

  18. Design of conveyor utilization monitoring system: a case study of powder coating line in sheet metal fabrication

    NASA Astrophysics Data System (ADS)

    Prasetyo, Hoedi; Sugiarto, Yohanes; Nur Rosyidi, Cucuk

    2018-03-01

    Conveyor is a very useful equipment to replace manpower in transporting the goods. It highly influences the productivity, production capacity utilization and eventually the production cost. This paper proposes a system to monitor the utilization of conveyor at a low cost through a case study at powder coating process line in a sheet metal fabrication. Preliminary observation was conducted to identify the problems. The monitoring system was then built and executed. The system consists of two sub systems. First is sub system for collecting and transmitting the required data and the second is sub system for displaying the data. The system utilizes sensors, wireless data transfer and windows-based application. The test results showed that the whole system works properly. By this system, the productivity and status of the conveyor can be monitored in real time. This research enriches the development of conveyor monitoring system especially for implementation in small and medium enterprises.

  19. International remote monitoring project Argentina Nuclear Power Station Spent Fuel Transfer Remote Monitoring System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schneider, S.; Lucero, R.; Glidewell, D.

    1997-08-01

    The Autoridad Regulataria Nuclear (ARN) and the United States Department of Energy (DOE) are cooperating on the development of a Remote Monitoring System for nuclear nonproliferation efforts. A Remote Monitoring System for spent fuel transfer will be installed at the Argentina Nuclear Power Station in Embalse, Argentina. The system has been designed by Sandia National Laboratories (SNL), with Los Alamos National Laboratory (LANL) and Oak Ridge National Laboratory (ORNL) providing gamma and neutron sensors. This project will test and evaluate the fundamental design and implementation of the Remote Monitoring System in its application to regional and international safeguards efficiency. Thismore » paper provides a description of the monitoring system and its functions. The Remote Monitoring System consists of gamma and neutron radiation sensors, RF systems, and video systems integrated into a coherent functioning whole. All sensor data communicate over an Echelon LonWorks Network to a single data logger. The Neumann DCM 14 video module is integrated into the Remote Monitoring System. All sensor and image data are stored on a Data Acquisition System (DAS) and archived and reviewed on a Data and Image Review Station (DIRS). Conventional phone lines are used as the telecommunications link to transmit on-site collected data and images to remote locations. The data and images are authenticated before transmission. Data review stations will be installed at ARN in Buenos Aires, Argentina, ABACC in Rio De Janeiro, IAEA Headquarters in Vienna, and Sandia National Laboratories in Albuquerque, New Mexico. 2 refs., 2 figs.« less

  20. [Evaluation and analysis of monitoring and early warning functions of the occupational disease reporting system in China].

    PubMed

    Zhu, Xiaojun; Li, Tao; Liu, Mengxuan

    2015-06-01

    To evaluate the monitoring and early warning functions of the occupational disease reporting system right now in China, and to analyze their influencing factors. An improved audit tool (ODIT) was used to score the monitoring and early warning functions with a total score of 10. The nine indices were completeness of information on the reporting form, coverage of the reporting system, accessibility of criteria or guidelines for diagnosis, education and training for physicians, completeness of the reporting system, statistical methods, investigation of special cases, release of monitoring information, and release of early warning information. According to the evaluation, the occupational disease reporting system in China had a score of 5.5 in monitoring existing occupational diseases with a low score for release of monitoring information; the reporting system had a score of 6.5 in early warning of newly occurring occupational diseases with low scores for education and training for physicians as well as completeness of the reporting system. The occupational disease reporting system in China still does not have full function in monitoring and early warning. It is the education and participation of physicians from general hospitals in the diagnosis and treatment of occupational diseases and suspected occupational diseases that need to be enhanced. In addition, the problem of monitoring the incidence of occupational diseases needs to be solved as soon as possible.

  1. Development of a New ICT-Based Multisensor Blood Pressure Monitoring System for Use in Hemodynamic Biomarker-Initiated Anticipation Medicine for Cardiovascular Disease: The National IMPACT Program Project.

    PubMed

    Kario, Kazuomi; Tomitani, Naoko; Kanegae, Hiroshi; Yasui, Nobuhiko; Nishizawa, Masafumi; Fujiwara, Takeshi; Shigezumi, Takeya; Nagai, Ryozo; Harada, Hiroshi

    We have developed a multisensor home and ambulatory blood pressure (BP) monitoring system for monitoring 24-h central and brachial BP variability concurrent with physical activity (PA), temperature, and atmospheric pressure. The new BP monitoring system utilizes our recently developed biological and environmental signal monitoring Information Communication Technology/Internet of Things system, which can simultaneously monitor the environment (temperature, illumination, etc.) of different rooms in a house (entryway, bedroom, living room, bathing room, and toilet), and a wrist-type high-sensitivity actigraph for identifying the location of patients. By collecting both data on BP and environmental parameters, the system can assess the brachial and central hemodynamic BP reactivity profiles of patients, such as actisensitivity (BP change with PA), thermosensitivity (with temperature), and atmospheric sensitivity (with atmospheric pressure). We used this new system to monitor ambulatory BP variability in outpatients with one or more cardiovascular disease (CVD) risk factors both in summer and winter. Actisensitivity (the slope of the regression line of ambulatory BP against the log-physical activity) was higher in winter than summer. By multi-level analysis using the parameters monitored by this system, we estimated the ambulatory BPs under different conditions. The individual time-series big data collected by this system will contribute to anticipation medicine for CVD. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. A custom acoustic emission monitoring system for harsh environments: application to freezing-induced damage in alpine rock-walls

    NASA Astrophysics Data System (ADS)

    Girard, L.; Beutel, J.; Gruber, S.; Hunziker, J.; Lim, R.; Weber, S.

    2012-06-01

    We present a custom acoustic emission (AE) monitoring system designed to perform long-term measurements on high-alpine rock-walls. AE monitoring is a common technique for characterizing damage evolution in solid materials. The system is based on a two-channel AE sensor node (AE-node) integrated into a Wireless Sensor Network (WSN) customized for operation in harsh environments. This wireless architecture offers flexibility in the deployment of AE-nodes at any position of the rock-wall that needs to be monitored, within a range of a few hundred meters from a core station connected to the internet. The system achieves near real-time data delivery and allows the user to remotely control the AE detection threshold. In order to protect AE sensors and capture acoustic signals from specific depths of the rock-wall, a special casing was developed. The monitoring system is completed by two probes that measure rock temperature and liquid water content, both probes being also integrated into the WSN. We report a first deployment of the monitoring system on a rock-wall at Jungfraujoch, 3500 m a.s.l., Switzerland. While this first deployment of the monitoring system aims to support fundamental research on processes that damage rock under cold climate, the system could serve a number of other applications, including rock-fall hazard surveillance or structural monitoring of concrete structures.

  3. A custom acoustic emission monitoring system for harsh environments: application to freezing-induced damage in alpine rock walls

    NASA Astrophysics Data System (ADS)

    Girard, L.; Beutel, J.; Gruber, S.; Hunziker, J.; Lim, R.; Weber, S.

    2012-11-01

    We present a custom acoustic emission (AE) monitoring system designed to perform long-term measurements on high-alpine rock walls. AE monitoring is a common technique for characterizing damage evolution in solid materials. The system is based on a two-channel AE sensor node (AE-node) integrated into a wireless sensor network (WSN) customized for operation in harsh environments. This wireless architecture offers flexibility in the deployment of AE-nodes at any position of the rock wall that needs to be monitored, within a range of a few hundred meters from a core station connected to the internet. The system achieves near real-time data delivery and allows the user to remotely control the AE detection threshold. In order to protect AE sensors and capture acoustic signals from specific depths of the rock wall, a special casing was developed. The monitoring system is completed by two probes that measure rock temperature and liquid water content, both probes being also integrated into the WSN. We report a first deployment of the monitoring system on a rock wall at Jungfraujoch, 3500 m a.s.l., Switzerland. While this first deployment of the monitoring system aims to support fundamental research on processes that damage rock under cold climate, the system could serve a number of other applications, including rock fall hazard surveillance or structural monitoring of concrete structures.

  4. Feasibility of wake vortex monitoring systems for air terminals

    NASA Technical Reports Server (NTRS)

    Wilson, D. J.; Shrider, K. R.; Lawrence, T. R.

    1972-01-01

    Wake vortex monitoring systems, especially those using laser Doppler sensors, were investigated. The initial phases of the effort involved talking with potential users (air traffic controllers, pilots, etc.) of a wake vortex monitoring system to determine system requirements from the user's viewpoint. These discussions involved the volumes of airspace to be monitored for vortices, and potential methods of using the monitored vortex data once the data are available. A subsequent task led to determining a suitable mathematical model of the vortex phenomena and developing a mathematical model of the laser Doppler sensor for monitoring the vortex flow field. The mathematical models were used in combination to help evaluate the capability of laser Doppler instrumentation in monitoring vortex flow fields both in the near vicinity of the sensor (within 1 kilometer and at long ranges(10 kilometers).

  5. A Wireless Monitoring System for Cracks on the Surface of Reactor Containment Buildings.

    PubMed

    Zhou, Jianguo; Xu, Yaming; Zhang, Tao

    2016-06-14

    Structural health monitoring with wireless sensor networks has been increasingly popular in recent years because of the convenience. In this paper, a real-time monitoring system for cracks on the surface of reactor containment buildings is presented. Customized wireless sensor networks platforms are designed and implemented with sensors especially for crack monitoring, which include crackmeters and temperature detectors. Software protocols like route discovery, time synchronization and data transfer are developed to satisfy the requirements of the monitoring system and stay simple at the same time. Simulation tests have been made to evaluate the performance of the system before full scale deployment. The real-life deployment of the crack monitoring system is carried out on the surface of reactor containment building in Daya Bay Nuclear Power Station during the in-service pressure test with 30 wireless sensor nodes.

  6. Attitudes of Austrian Psychotherapists Towards Process and Outcome Monitoring.

    PubMed

    Kaiser, Tim; Schmutzhart, Lisa; Laireiter, Anton-Rupert

    2018-03-08

    While monitoring systems in psychotherapy have become more common, little is known about the attitudes that mental health practitioners have towards these systems. In an online survey among 111 Austrian psychotherapists and trainees, attitudes towards therapy monitoring were measured. A well-validated questionnaire measuring attitudes towards outcome monitoring, the Outcome Measurement Questionnaire, was used. Clinicians' theoretical orientations as well as previous knowledge and experience with monitoring systems were associated with positive attitudes towards monitoring. Possible factors that may have led to these findings, like the views of different theoretical orientations or obstacles in Austrian public health care, are discussed.

  7. A Fiber Bragg Grating-Based Monitoring System for Roof Safety Control in Underground Coal Mining

    PubMed Central

    Zhao, Yiming; Zhang, Nong; Si, Guangyao

    2016-01-01

    Monitoring of roof activity is a primary measure adopted in the prevention of roof collapse accidents and functions to optimize and support the design of roadways in underground coalmines. However, traditional monitoring measures, such as using mechanical extensometers or electronic gauges, either require arduous underground labor or cannot function properly in the harsh underground environment. Therefore, in this paper, in order to break through this technological barrier, a novel monitoring system for roof safety control in underground coal mining, using fiber Bragg grating (FBG) material as a perceived element and transmission medium, has been developed. Compared with traditional monitoring equipment, the developed, novel monitoring system has the advantages of providing accurate, reliable, and continuous online monitoring of roof activities in underground coal mining. This is expected to further enable the prevention of catastrophic roof collapse accidents. The system has been successfully implemented at a deep hazardous roadway in Zhuji Coal Mine, China. Monitoring results from the study site have demonstrated the advantages of FBG-based sensors over traditional monitoring approaches. The dynamic impacts of progressive face advance on roof displacement and stress have been accurately captured by the novel roadway roof activity and safety monitoring system, which provided essential references for roadway support and design of the mine. PMID:27775657

  8. On the efficiency of driver state monitoring systems

    NASA Astrophysics Data System (ADS)

    Dementienko, V. V.; Dorokhov, V. B.; Gerus, S. V.; Markov, A. G.; Shakhnarovich, V. M.

    2007-06-01

    Statistical data on road traffic and the results of laboratory studies are used to construct a mathematical model of a driver-driver state monitor-automobile-traffic system. In terms of the model, the probability of an accident resulting from the drowsy state of the driver is determined both in the absence and presence of a monitor. The model takes into account the efficiency and safety level provided by different monitoring systems, as well as psychological factors associated with the excessive reliance of drivers upon monitoring.

  9. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT ANR PIPELINE COMPANY PARAMETRIC EMISSIONS MONITORING SYSTEM (PEMS)

    EPA Science Inventory

    The Environmental Technology Verification report discusses the technology and performance of a gaseous-emissions monitoring system for large, natural-gas-fired internal combustion engines. The device tested is the Parametric Emissions Monitoring System (PEMS) manufactured by ANR ...

  10. Data Link Test and Analysis System/TCAS Monitor User's Guide

    DOT National Transportation Integrated Search

    1991-02-01

    This document is a user's guide for the Data Link Test and Analysis System : (DATAS) Traffic Alert and Collision Avoidance System (TCAS) monitor application. : It provides a brief overall hardware description of DATAS configured as a TCAS : Monitor, ...

  11. [A wireless mobile monitoring system based on bluetooth technology].

    PubMed

    Sun, Shou-jun; Wu, Kai; Wu, Xiao-Ming

    2006-09-01

    This paper presents a wireless mobile monitoring system based on Bluetooth technology. This system realizes the remote mobile monitoring of multiple physiological parameters, and has the characters of easy use, low cost, good reliability and strong capability of anti-jamming.

  12. The design of remote temperature monitoring system

    NASA Astrophysics Data System (ADS)

    Li, Biqing; Li, Zhao; Wei, Liuren

    2017-08-01

    This design is made on the basis of the single-chip microcomputer remote temperature monitoring system. STC89C51RC is the main core part, this design use the sensor DHT11 of temperature or humidity and wireless transceiver NRF24L01 the temperature of the test site for long-range wireless measurement and monitoring. The design contains the main system and the small system, of which the main system can show the actual test site temperature and humidity values, voice broadcast, out of control and receive data alarm function; The small system has the function of temperature and humidity, temperature monitoring and sending data. After debugging, the user customizable alarm upper and lower temperature, when the temperature exceeds limit value, the main system of buzzer alarm immediately. The system has simple structure, complete functions and can alarm in time, it can be widely used remote temperature acquisition and monitoring of the site.

  13. The immunization data quality audit: verifying the quality and consistency of immunization monitoring systems.

    PubMed Central

    Ronveaux, O.; Rickert, D.; Hadler, S.; Groom, H.; Lloyd, J.; Bchir, A.; Birmingham, M.

    2005-01-01

    OBJECTIVE: To evaluate the consistency and quality of immunization monitoring systems in 27 countries during 2002-03 using standardized data quality audits (DQAs) that had been launched within the framework of the Global Alliance for Vaccines and Immunization. METHODS: The consistency of reporting systems was estimated by determining the proportion of third doses of diphtheria-tetanuspertussis (DTP-3) vaccine reported as being administered that could be verified by written documentation at health facilities and districts. The quality of monitoring systems was measured using quality indices for different components of the monitoring systems. These indices were applied to each level of the health service (health unit, district and national). FINDINGS: The proportion of verified DTP-3 doses was lower than 85% in 16 countries. Difficulties in verifying the doses administered often arose at the peripheral level of the health service, usually as the result of discrepancies in information between health units and their corresponding districts or because completed recording forms were not available from health units. All countries had weaknesses in their monitoring systems; these included the inconsistent use of monitoring charts; inadequate monitoring of vaccine stocks, injection supplies and adverse events; unsafe computer practices; and poor monitoring of completeness and timeliness of reporting. CONCLUSION: Inconsistencies in immunization data occur in many countries, hampering their ability to manage their immunization programmes. Countries should use these findings to strengthen monitoring systems so that data can reliably guide programme activities. The DQA is an innovative tool that provides a way to independently assess the quality of immunization monitoring systems at all levels of a health service and serves as a point of entry to make improvements. It provides a useful example for other global health initiatives. PMID:16175824

  14. Monitoring operational data production applying Big Data tooling

    NASA Astrophysics Data System (ADS)

    Som de Cerff, Wim; de Jong, Hotze; van den Berg, Roy; Bos, Jeroen; Oosterhoff, Rijk; Klein Ikkink, Henk Jan; Haga, Femke; Elsten, Tom; Verhoef, Hans; Koutek, Michal; van de Vegte, John

    2015-04-01

    Within the KNMI Deltaplan programme for improving the KNMI operational infrastructure an new fully automated system for monitoring the KNMI operational data production systems is being developed: PRISMA (PRocessflow Infrastructure Surveillance and Monitoring Application). Currently the KNMI operational (24/7) production systems consist of over 60 applications, running on different hardware systems and platforms. They are interlinked for the production of numerous data products, which are delivered to internal and external customers. All applications are individually monitored by different applications, complicating root cause and impact analysis. Also, the underlying hardware and network is monitored separately using Zabbix. Goal of the new system is to enable production chain monitoring, which enables root cause analysis (what is the root cause of the disruption) and impact analysis (what other products will be effected). The PRISMA system will make it possible to dispose all the existing monitoring applications, providing one interface for monitoring the data production. For modeling the production chain, the Neo4j Graph database is used to store and query the model. The model can be edited through the PRISMA web interface, but is mainly automatically provided by the applications and systems which are to be monitored. The graph enables us to do root case and impact analysis. The graph can be visualized in the PRISMA web interface on different levels. Each 'monitored object' in the model will have a status (OK, error, warning, unknown). This status is derived by combing all log information available. For collecting and querying the log information Splunk is used. The system is developed using Scrum, by a multi-disciplinary team consisting of analysts, developers, a tester and interaction designer. In the presentation we will focus on the lessons learned working with the 'Big data' tooling Splunk and Neo4J.

  15. The evolution of computer monitoring of real time data during the Atlas Centaur launch countdown

    NASA Technical Reports Server (NTRS)

    Thomas, W. F.

    1981-01-01

    In the last decade, improvements in computer technology have provided new 'tools' for controlling and monitoring critical missile systems. In this connection, computers have gradually taken a large role in monitoring all flights and ground systems on the Atlas Centaur. The wide body Centaur which will be launched in the Space Shuttle Cargo Bay will use computers to an even greater extent. It is planned to use the wide body Centaur to boost the Galileo spacecraft toward Jupiter in 1985. The critical systems which must be monitored prior to liftoff are examined. Computers have now been programmed to monitor all critical parameters continuously. At this time, there are two separate computer systems used to monitor these parameters.

  16. Noninvasive Real-Time Assessment of Cell Viability in a Three-Dimensional Tissue.

    PubMed

    Mahfouzi, Seyed Hossein; Amoabediny, Ghassem; Doryab, Ali; Safiabadi-Tali, Seyed Hamid; Ghanei, Mostafa

    2018-04-01

    Maintaining cell viability within 3D tissue engineering scaffolds is an essential step toward a functional tissue or organ. Assessment of cell viability in 3D scaffolds is necessary to control and optimize tissue culture process. Monitoring systems based on respiration activity of cells (e.g., oxygen consumption) have been used in various cell cultures. In this research, an online monitoring system based on respiration activity was developed to monitor cell viability within acellular lung scaffolds. First, acellular lung scaffolds were recellularized with human umbilical cord vein endothelial cells, and then, cell viability was monitored during a 5-day period. The real-time monitoring system generated a cell growth profile representing invaluable information on cell viability and proliferative states during the culture period. The cell growth profile obtained by the monitoring system was consistent with 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide analysis and glucose consumption measurement. This system provided a means for noninvasive, real-time, and repetitive investigation of cell viability. Also, we showed the applicability of this monitoring system by introducing shaking as an operating parameter in a long-term culture.

  17. Long distance high power optical laser fiber break detection and continuity monitoring systems and methods

    DOEpatents

    Rinzler, Charles C.; Gray, William C.; Faircloth, Brian O.; Zediker, Mark S.

    2016-02-23

    A monitoring and detection system for use on high power laser systems, long distance high power laser systems and tools for performing high power laser operations. In particular, the monitoring and detection systems provide break detection and continuity protection for performing high power laser operations on, and in, remote and difficult to access locations.

  18. Design and modelling of a link monitoring mechanism for the Common Data Link (CDL)

    NASA Astrophysics Data System (ADS)

    Eichelberger, John W., III

    1994-09-01

    The Common Data Link (CDL) is a full duplex, point-to-point microwave communications system used in imagery and signals intelligence collection systems. It provides a link between two remote Local Area Networks (LAN's) aboard collection and surface platforms. In a hostile environment, there is an overwhelming need to dynamically monitor the link and thus, limit the impact of jamming. This work describes steps taken to design, model, and evaluate a link monitoring system suitable for the CDL. The monitoring system is based on features and monitoring constructs of the Link Control Protocol (LCP) in the Point-to-Point Protocol (PPP) suite. The CDL model is based on a system of two remote Fiber Distributed Data Interface (FDDI) LAN's. In particular, the policies and mechanisms associated with monitoring are described in detail. An implementation of the required mechanisms using the OPNET network engineering tool is described. Performance data related to monitoring parameters is reported. Finally, integration of the FDDI-CDL model with the OPNET Internet model is described.

  19. Autonomous System for Monitoring the Integrity of Composite Fan Housings

    NASA Technical Reports Server (NTRS)

    Qing, Xinlin P.; Aquino, Christopher; Kumar, Amrita

    2010-01-01

    A low-cost and reliable system assesses the integrity of composite fan-containment structures. The system utilizes a network of miniature sensors integrated with the structure to scan the entire structural area for any impact events and resulting structural damage, and to monitor degradation due to usage. This system can be used to monitor all types of composite structures on aircraft and spacecraft, as well as automatically monitor in real time the location and extent of damage in the containment structures. This diagnostic information is passed to prognostic modeling that is being developed to utilize the information and provide input on the residual strength of the structure, and maintain a history of structural degradation during usage. The structural health-monitoring system would consist of three major components: (1) sensors and a sensor network, which is permanently bonded onto the structure being monitored; (2) integrated hardware; and (3) software to monitor in-situ the health condition of in-service structures.

  20. 40 CFR 60.1735 - Am I exempt from any appendix B or appendix F requirements to evaluate continuous emission...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... appendix F requirements to evaluate continuous emission monitoring systems? 60.1735 Section 60.1735... systems? Yes, the accuracy tests for your sulfur dioxide continuous emission monitoring system require you to also evaluate your oxygen (or carbon dioxide) continuous emission monitoring system. Therefore...

  1. 76 FR 38107 - Atlantic Highly Migratory Species; Vessel Monitoring Systems; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-29

    .... 110520295-1295-01] RIN 0648-BA64 Atlantic Highly Migratory Species; Vessel Monitoring Systems; Correction... Monitoring System requirements in Atlantic HMS fisheries. The document contained an incorrect time for a..., 2011 3:30-6:30 p.m Atlantic County Library System, Brigantine Branch, 201 15th St. South, Brigantine...

  2. 40 CFR 60.1735 - Am I exempt from any appendix B or appendix F requirements to evaluate continuous emission...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... appendix F requirements to evaluate continuous emission monitoring systems? 60.1735 Section 60.1735... systems? Yes, the accuracy tests for your sulfur dioxide continuous emission monitoring system require you to also evaluate your oxygen (or carbon dioxide) continuous emission monitoring system. Therefore...

  3. Recent Changes in State Special Education Part B Monitoring Systems.

    ERIC Educational Resources Information Center

    Tschantz, Jennifer

    The document reports the changes states have made in their monitoring of the provision of special education services by local education agencies from 1997 to 2001. It includes a brief background on the federal monitoring process and an outline of the federal requirements for state monitoring. Changes in state monitoring systems are discussed,…

  4. 40 CFR 86.005-17 - On-board diagnostics.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... other available operating parameters), and functionality checks for computer output components (proper... considered acceptable. (e) Storing of computer codes. The OBD system shall record and store in computer... monitors that can be considered continuously operating monitors (e.g., misfire monitor, fuel system monitor...

  5. 40 CFR 86.005-17 - On-board diagnostics.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... other available operating parameters), and functionality checks for computer output components (proper... considered acceptable. (e) Storing of computer codes. The OBD system shall record and store in computer... monitors that can be considered continuously operating monitors (e.g., misfire monitor, fuel system monitor...

  6. Hybrid wireless sensor network for rescue site monitoring after earthquake

    NASA Astrophysics Data System (ADS)

    Wang, Rui; Wang, Shuo; Tang, Chong; Zhao, Xiaoguang; Hu, Weijian; Tan, Min; Gao, Bowei

    2016-07-01

    This paper addresses the design of a low-cost, low-complexity, and rapidly deployable wireless sensor network (WSN) for rescue site monitoring after earthquakes. The system structure of the hybrid WSN is described. Specifically, the proposed hybrid WSN consists of two kinds of wireless nodes, i.e., the monitor node and the sensor node. Then the mechanism and the system configuration of the wireless nodes are detailed. A transmission control protocol (TCP)-based request-response scheme is proposed to allow several monitor nodes to communicate with the monitoring center. UDP-based image transmission algorithms with fast recovery have been developed to meet the requirements of in-time delivery of on-site monitor images. In addition, the monitor node contains a ZigBee module that used to communicate with the sensor nodes, which are designed with small dimensions to monitor the environment by sensing different physical properties in narrow spaces. By building a WSN using these wireless nodes, the monitoring center can display real-time monitor images of the monitoring area and visualize all collected sensor data on geographic information systems. In the end, field experiments were performed at the Training Base of Emergency Seismic Rescue Troops of China and the experimental results demonstrate the feasibility and effectiveness of the monitor system.

  7. Development of a component centered fault monitoring and diagnosis knowledge based system for space power system

    NASA Technical Reports Server (NTRS)

    Lee, S. C.; Lollar, Louis F.

    1988-01-01

    The overall approach currently being taken in the development of AMPERES (Autonomously Managed Power System Extendable Real-time Expert System), a knowledge-based expert system for fault monitoring and diagnosis of space power systems, is discussed. The system architecture, knowledge representation, and fault monitoring and diagnosis strategy are examined. A 'component-centered' approach developed in this project is described. Critical issues requiring further study are identified.

  8. Body surface mounted biomedical monitoring system using Bluetooth.

    PubMed

    Nambu, Masayuki

    2007-01-01

    Continuous monitoring in daily life is important for the health condition control of the elderly. However, portable or wearable devices need to carry by user on their own will. On the other hand, implantation sensors are not adoptable, because of generic users dislike to insert the any object in the body for monitoring. Therefore, another monitoring system of the health condition to carry it easily is necessary. In addition, ID system is necessary even if the subject live with few families. Furthermore, every measurement system should be wireless system, because not to obstruct the daily life of the user. In this paper, we propose the monitoring system, which is mounted on the body surface. This system will not obstruct the action or behavior of user in daily life, because this system attached the body surface on the back of the user. In addition, this system has wireless communication system, using Bluetooth, and acquired data transfer to the outside of the house via the Internet.

  9. Effectiveness of a simple and real-time baseline shift monitoring system during stereotactic body radiation therapy of lung tumors.

    PubMed

    Uchida, Yukihiro; Tachibana, Hidenobu; Kamei, Yoshiyuki; Kashihara, Kenichi

    2017-11-01

    This study aimed to clinically validate a simple real-time baseline shift monitoring system in a prospective study of consecutive patients undergoing stereotactic body radiation therapy (SBRT) of lung tumors, and to investigate baseline shift due to intrafraction motion of the patient's body during lung SBRT. Ten consecutive patients with peripheral lung tumors were treated by SBRT consisting of four fractions of 12 Gy each, with a total dose of 48 Gy. During treatment, each patient's geometric displacement in the anterior-posterior and left-right directions (the baseline shift) was measured using a real-time monitoring webcam system. Displacement between the start and end of treatment was measured using an X-ray fluoroscopic imaging system. The displacement measurements of the two systems were compared, and the measurements of baseline shift acquired by the monitoring system during treatment were analyzed for all patients. There was no significant deviation between the monitoring system and the X-ray imaging system, with the accuracy of measurement being within 1 mm. Measurements using the monitoring system showed that 7 min of treatment generated displacements of more than 1 mm in 50% of the patients. Baseline shift of a patient's body may be measured accurately in real time, using a monitoring system without X-ray exposure. The manubrium of the sternum is a good location for measuring the baseline shift of a patient's body at all times. The real-time monitoring system may be useful for measuring the baseline shift of a patient's body independently of a gating system. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  10. Development of GUI Type On-Line Condition Monitoring Program for a Turboprop Engine Using Labview

    NASA Astrophysics Data System (ADS)

    Kong, Changduk; Kim, Keonwoo

    2011-12-01

    Recently, an aero gas turbine health monitoring system has been developed for precaution and maintenance action against faults or performance degradations of the advanced propulsion system which occurs in severe environments such as high altitude, foreign object damage particles, hot and heavy rain and snowy atmospheric conditions. However to establish this health monitoring system, the online condition monitoring program is firstly required, and the program must monitor the engine performance trend through comparison between measured engine performance data and base performance results calculated by base engine performance model. This work aims to develop a GUI type on-line condition monitoring program for the PT6A-67 turboprop engine of a high altitude and long endurance operation UAV using LabVIEW. The base engine performance of the on-line condition monitoring program is simulated using component maps inversely generated from the limited performance deck data provided by engine manufacturer. The base engine performance simulation program is evaluated because analysis results by this program agree well with the performance deck data. The proposed on-line condition program can monitor the real engine performance as well as the trend through precise comparison between clean engine performance results calculated by the base performance simulation program and measured engine performance signals. In the development phase of this monitoring system, a signal generation module is proposed to evaluate the proposed online monitoring system. For user friendly purpose, all monitoring program are coded by LabVIEW, and monitoring examples are demonstrated using the proposed GUI type on-condition monitoring program.

  11. Technology evaluation of control/monitoring systems for MIUS application. [utility services management

    NASA Technical Reports Server (NTRS)

    Pringle, L. M., Jr.

    1974-01-01

    Potential ways of providing control and monitoring for the Modular Integrated Utility System (MIUS) program are elaborated. Control and monitoring hardware and operational systems are described. The requirements for the MIUS program and the development requirements are discussed.

  12. 30 CFR 27.2 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... MINING PRODUCTS METHANE-MONITORING SYSTEMS General Provisions § 27.2 Definitions. As used in this part... designs, manufactures, or assembles and that seeks certification or preliminary testing of a methane-monitoring system or component. (c) Methane-monitoring system means a complete assembly of one or more...

  13. Integrated Analysis Tools for the NERRS System-Wide Monitoring Program Data

    EPA Science Inventory

    Standardized monitoring programs have vastly improved the quantity and quality of data that form the basis of environmental decision-making. One example is the NOAA-funded National Estuarine Research Reserve System (NERRS) System-wide Monitoring Program (SWMP) that was implement...

  14. WATER QUALITY EARLY WARNING SYSTEMS FOR SOURCE WATER AND DISTRIBUTION SYSTEM MONITORING

    EPA Science Inventory

    A variety of probes for use in continuous monitoring of water quality exist. They range from single parameter chemical/physical probes to comprehensive screening systems based on whole organism responses. Originally developed for monitoring specific characteristics of water qua...

  15. Data link test and analysis system/TCAS monitor user's guide

    NASA Astrophysics Data System (ADS)

    Vandongen, John; Wapelhorst, Leo

    1991-02-01

    This document is a user's guide for the Data Link Test and Analysis System (DATAS) Traffic Alert and Collision Avoidance System (TCAS) monitor. It provides a brief overall hardware description of DATAS configured as a TCAS monitor, and the applications software.

  16. 78 FR 55060 - Proposed Information Collection; Comment Request; Expanded Vessel Monitoring System Requirement...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-09

    ... DEPARTMENT OF COMMERCE National Oceanic and Atmospheric Administration Proposed Information Collection; Comment Request; Expanded Vessel Monitoring System Requirement in the Pacific Coast Groundfish... and use a vessel monitoring system (VMS) that automatically sends hourly position reports. Exemptions...

  17. 76 FR 38598 - Atlantic Highly Migratory Species; Vessel Monitoring Systems

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-01

    ... DEPARTMENT OF COMMERCE National Oceanic and Atmospheric Administration 50 CFR Part 635 RIN 0648-BA64 Atlantic Highly Migratory Species; Vessel Monitoring Systems AGENCY: National Marine Fisheries... on June 21, 2011, concerning modifications to vessel monitoring system (VMS) requirements in Atlantic...

  18. The CUORE slow monitoring systems

    NASA Astrophysics Data System (ADS)

    Gladstone, L.; Biare, D.; Cappelli, L.; Cushman, J. S.; Del Corso, F.; Fujikawa, B. K.; Hickerson, K. P.; Moggi, N.; Pagliarone, C. E.; Schmidt, B.; Wagaarachchi, S. L.; Welliver, B.; Winslow, L. A.

    2017-09-01

    CUORE is a cryogenic experiment searching primarily for neutrinoless double decay in 130Te. It will begin data-taking operations in 2016. To monitor the cryostat and detector during commissioning and data taking, we have designed and developed Slow Monitoring systems. In addition to real-time systems using LabVIEW, we have an alarm, analysis, and archiving website that uses MongoDB, AngularJS, and Bootstrap software. These modern, state of the art software packages make the monitoring system transparent, easily maintainable, and accessible on many platforms including mobile devices.

  19. Dielectric cure monitoring: Preliminary studies

    NASA Technical Reports Server (NTRS)

    Goldberg, B. E.; Semmel, M. L.

    1984-01-01

    Preliminary studies have been conducted on two types of dielectric cure monitoring systems employing both epoxy resins and phenolic composites. An Audrey System was used for 23 cure monitoring runs with very limited success. Nine complete cure monitoring runs have been investigated using a Micromet System. Two additional measurements were performed to investigate the Micromet's sensitivity to water absorption in a post-cure carbon-phenolic material. While further work is needed to determine data significance, the Micromet system appears to show promise as a feedback control device during processing.

  20. A System for Monitoring Employee Health in a Navy Occupational Setting.

    DTIC Science & Technology

    1980-12-30

    AD0AIGI 064 NAVAL HEALTH RESEARCH CENTER SAN DIEGO CA F/G 6/5 A SYSTEM FOR MONITORING EMPLOYEE HEALTH IN A NAVY OCCUPATIONAL --ETC(U) DEC 80 L...CALORWIM , NAVAL IMEDCAL. REEARC AIND DEVELOPMUT Claww KWh~v, - ji, A System for Monitoring Employee Health in a Navy Occupational Setting Larry Hermansen...and Health Act of 1970 and Executive Order 11807 have engendered a need for a comprehensive system that can monitor and document employee health and

  1. The development of control and monitoring system on marine current renewable energy Case study: strait of Toyapakeh - Nusa Penida, Bali

    NASA Astrophysics Data System (ADS)

    Arief, I. S.; Suherman, I. H.; Wardani, A. Y.; Baidowi, A.

    2017-05-01

    Control and monitoring system is a continuous process of securing the asset in the Marine Current Renewable Energy. A control and monitoring system is existed each critical components which is embedded in Failure Mode Effect Analysis (FMEA) method. As the result, the process in this paper developed through a matrix sensor. The matrix correlated to critical components and monitoring system which supported by sensors to conduct decision-making.

  2. The Overview of the Health Monitoring Management System

    NASA Astrophysics Data System (ADS)

    Zhong-Ji, Tan; Zhiqiang, Zhang; Yan-Bin, Shi

    The health monitoring management system has prominent function to improve the security and dependability of the aircraft, can also shortens the maintain cycle by a large margin, improves the sortie rate at the same time. This paper has explained the concept, the development in domestic and international and the key technology of the health monitoring management system of aircraft; Construct the structure of the aircraft health monitoring management system, and has carried on analysis and research to its implementation method.

  3. Design and implementation of a remote UAV-based mobile health monitoring system

    NASA Astrophysics Data System (ADS)

    Li, Songwei; Wan, Yan; Fu, Shengli; Liu, Mushuang; Wu, H. Felix

    2017-04-01

    Unmanned aerial vehicles (UAVs) play increasing roles in structure health monitoring. With growing mobility in modern Internet-of-Things (IoT) applications, the health monitoring of mobile structures becomes an emerging application. In this paper, we develop a UAV-carried vision-based monitoring system that allows a UAV to continuously track and monitor a mobile infrastructure and transmit back the monitoring information in real- time from a remote location. The monitoring system uses a simple UAV-mounted camera and requires only a single feature located on the mobile infrastructure for target detection and tracking. The computation-effective vision-based tracking solution based on a single feature is an improvement over existing vision-based lead-follower tracking systems that either have poor tracking performance due to the use of a single feature, or have improved tracking performance at a cost of the usage of multiple features. In addition, a UAV-carried aerial networking infrastructure using directional antennas is used to enable robust real-time transmission of monitoring video streams over a long distance. Automatic heading control is used to self-align headings of directional antennas to enable robust communication in mobility. Compared to existing omni-communication systems, the directional communication solution significantly increases the operation range of remote monitoring systems. In this paper, we develop the integrated modeling framework of camera and mobile platforms, design the tracking algorithm, develop a testbed of UAVs and mobile platforms, and evaluate system performance through both simulation studies and field tests.

  4. Power system monitoring and source control of the Space Station Freedom DC power system testbed

    NASA Technical Reports Server (NTRS)

    Kimnach, Greg L.; Baez, Anastacio N.

    1992-01-01

    Unlike a terrestrial electric utility which can purchase power from a neighboring utility, the Space Station Freedom (SSF) has strictly limited energy resources; as a result, source control, system monitoring, system protection, and load management are essential to the safe and efficient operation of the SSF Electric Power System (EPS). These functions are being evaluated in the DC Power Management and Distribution (PMAD) Testbed which NASA LeRC has developed at the Power System Facility (PSF) located in Cleveland, Ohio. The testbed is an ideal platform to develop, integrate, and verify power system monitoring and control algorithms. State Estimation (SE) is a monitoring tool used extensively in terrestrial electric utilities to ensure safe power system operation. It uses redundant system information to calculate the actual state of the EPS, to isolate faulty sensors, to determine source operating points, to verify faults detected by subsidiary controllers, and to identify high impedance faults. Source control and monitoring safeguard the power generation and storage subsystems and ensure that the power system operates within safe limits while satisfying user demands with minimal interruptions. System monitoring functions, in coordination with hardware implemented schemes, provide for a complete fault protection system. The objective of this paper is to overview the development and integration of the state estimator and the source control algorithms.

  5. Power system monitoring and source control of the Space Station Freedom dc-power system testbed

    NASA Technical Reports Server (NTRS)

    Kimnach, Greg L.; Baez, Anastacio N.

    1992-01-01

    Unlike a terrestrial electric utility which can purchase power from a neighboring utility, the Space Station Freedom (SSF) has strictly limited energy resources; as a result, source control, system monitoring, system protection, and load management are essential to the safe and efficient operation of the SSF Electric Power System (EPS). These functions are being evaluated in the dc Power Management and Distribution (PMAD) Testbed which NASA LeRC has developed at the Power System Facility (PSF) located in Cleveland, Ohio. The testbed is an ideal platform to develop, integrate, and verify power system monitoring and control algorithms. State Estimation (SE) is a monitoring tool used extensively in terrestrial electric utilities to ensure safe power system operation. It uses redundant system information to calculate the actual state of the EPS, to isolate faulty sensors, to determine source operating points, to verify faults detected by subsidiary controllers, and to identify high impedance faults. Source control and monitoring safeguard the power generation and storage subsystems and ensure that the power system operates within safe limits while satisfying user demands with minimal interruptions. System monitoring functions, in coordination with hardware implemented schemes, provide for a complete fault protection system. The objective of this paper is to overview the development and integration of the state estimator and the source control algorithms.

  6. Field evaluation of Fourier transform infrared continuous emissions monitoring (FTIR CEM) systems

    NASA Astrophysics Data System (ADS)

    Dunder, Thomas A.; Geyer, Thomas J.; Kinner, Laura L.; Plummer, Grant M.

    1995-02-01

    Recent environmental regulations, including the Clean Air Act and the Enhanced Monitoring Regulations, may require continuous emissions monitoring (CEM) of hazardous air pollutants (HAPs). A promising technique for this application is Fourier transform infrared spectroscopy (FTIR). FTIR spectroscopy can, in principle, be used to monitor virtually any gas phase species. Two evaluations of FTIR CEM systems are discussed. The first study, performed in 1993 - 94, compared two FTIR CEM systems on a side-by-side basis in an extended field test at two coal-fired electric power plants. The FTIR CEM systems monitored the legally mandated criteria pollutants and diluents (CO, CO2, NO, NO2, and SO2) as well as H2O. In addition, one system monitored two HAPs (HCl and HF) and NH3. The FTIR CEM measurements were compared with those from the compliance CEM systems at the facilities. Several relative accuracy test audits were also performed to verify the FTIR CEM accuracy. The second evaluation was recently commenced on behalf of the Environmental Protection Agency. In this study, FTIR CEM systems are evaluated specifically for the monitoring of HAP species by conducting laboratory and field tests. The evaluation culminates in the development of proposed performance specifications and protocols for FTIR CEM systems.

  7. Real-time monitoring system for improving corona electrostatic separation in the process of recovering waste printed circuit boards.

    PubMed

    Li, Jia; Zhou, Quan; Xu, Zhenming

    2014-12-01

    Although corona electrostatic separation is successfully used in recycling waste printed circuit boards in industrial applications, there are problems that cannot be resolved completely, such as nonmetal particle aggregation and spark discharge. Both of these problems damage the process of separation and are not easy to identify during the process of separation in industrial applications. This paper provides a systematic study on a real-time monitoring system. Weight monitoring systems were established to continuously monitor the separation process. A Virtual Instrumentation program written by LabVIEW was utilized to sample and analyse the mass increment of the middling product. It includes four modules: historical data storage, steady-state analysis, data computing and alarm. Three kinds of operating conditions were used to verify the applicability of the monitoring system. It was found that the system achieved the goal of monitoring during the separation process and realized the function of real-time analysis of the received data. The system also gave comprehensible feedback on the accidents of material blockages in the feed inlet and high-voltage spark discharge. With the warning function of the alarm system, the whole monitoring system could save the human cost and help the new technology to be more easily applied in industry. © The Author(s) 2014.

  8. Implementing an electronic hand hygiene monitoring system: Lessons learned from community hospitals.

    PubMed

    Edmisten, Catherine; Hall, Charles; Kernizan, Lorna; Korwek, Kimberly; Preston, Aaron; Rhoades, Evan; Shah, Shalin; Spight, Lori; Stradi, Silvia; Wellman, Sonia; Zygadlo, Scott

    2017-08-01

    Measuring and providing feedback about hand hygiene (HH) compliance is a complicated process. Electronic HH monitoring systems have been proposed as a possible solution; however, there is little information available about how to successfully implement and maintain these systems for maximum benefit in community hospitals. An electronic HH monitoring system was implemented in 3 community hospitals by teams at each facility with support from the system vendor. Compliance rates were measured by the electronic monitoring system. The implementation challenges, solutions, and drivers of success were monitored within each facility. The electronic HH monitoring systems tracked on average more than 220,000 compliant HH events per facility per month, with an average monthly compliance rate >85%. The sharing of best practices between facilities was valuable in addressing challenges encountered during implementation and maintaining a high rate of use. Drivers of success included a collaborative environment, leadership commitment, using data to drive improvement, consistent and constant messaging, staff empowerment, and patient involvement. Realizing the full benefit of investments in electronic HH monitoring systems requires careful consideration of implementation strategies, planning for ongoing support and maintenance, and presenting data in a meaningful way to empower and inspire staff. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  9. Real-time indoor monitoring system based on wireless sensor networks

    NASA Astrophysics Data System (ADS)

    Wu, Zhengzhong; Liu, Zilin; Huang, Xiaowei; Liu, Jun

    2008-10-01

    Wireless sensor networks (WSN) greatly extend our ability to monitor and control the physical world. It can collaborate and aggregate a huge amount of sensed data to provide continuous and spatially dense observation of environment. The control and monitoring of indoor atmosphere conditions represents an important task with the aim of ensuring suitable working and living spaces to people. However, the comprehensive air quality, which includes monitoring of humidity, temperature, gas concentrations, etc., is not so easy to be monitored and controlled. In this paper an indoor WSN monitoring system was developed. In the system several sensors such as temperature sensor, humidity sensor, gases sensor, were built in a RF transceiver board for monitoring indoor environment conditions. The indoor environmental monitoring parameters can be transmitted by wireless to database server and then viewed throw PC or PDA accessed to the local area networks by administrators. The system, which was also field-tested and showed a reliable and robust characteristic, is significant and valuable to people.

  10. Total On-line Access Data System (TOADS): Phase II Final Report for the Period August 2002 - August 2004

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yuracko, K. L.; Parang, M.; Landguth, D. C.

    2004-09-13

    TOADS (Total On-line Access Data System) is a new generation of real-time monitoring and information management system developed to support unattended environmental monitoring and long-term stewardship of U.S. Department of Energy facilities and sites. TOADS enables project managers, regulators, and stakeholders to view environmental monitoring information in realtime over the Internet. Deployment of TOADS at government facilities and sites will reduce the cost of monitoring while increasing confidence and trust in cleanup and long term stewardship activities. TOADS: Reliably interfaces with and acquires data from a wide variety of external databases, remote systems, and sensors such as contaminant monitors, areamore » monitors, atmospheric condition monitors, visual surveillance systems, intrusion devices, motion detectors, fire/heat detection devices, and gas/vapor detectors; Provides notification and triggers alarms as appropriate; Performs QA/QC on data inputs and logs the status of instruments/devices; Provides a fully functional data management system capable of storing, analyzing, and reporting on data; Provides an easy-to-use Internet-based user interface that provides visualization of the site, data, and events; and Enables the community to monitor local environmental conditions in real time. During this Phase II STTR project, TOADS has been developed and successfully deployed for unattended facility, environmental, and radiological monitoring at a Department of Energy facility.« less

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maxwell, Don E; Ezell, Matthew A; Becklehimer, Jeff

    While sites generally have systems in place to monitor the health of Cray computers themselves, often the cooling systems are ignored until a computer failure requires investigation into the source of the failure. The Liebert XDP units used to cool the Cray XE/XK models as well as the Cray proprietary cooling system used for the Cray XC30 models provide data useful for health monitoring. Unfortunately, this valuable information is often available only to custom solutions not accessible by a center-wide monitoring system or is simply ignored entirely. In this paper, methods and tools used to harvest the monitoring data availablemore » are discussed, and the implementation needed to integrate the data into a center-wide monitoring system at the Oak Ridge National Laboratory is provided.« less

  12. Technology Transfer Opportunities: Automated Ground-Water Monitoring

    USGS Publications Warehouse

    Smith, Kirk P.; Granato, Gregory E.

    1997-01-01

    Introduction A new automated ground-water monitoring system developed by the U.S. Geological Survey (USGS) measures and records values of selected water-quality properties and constituents using protocols approved for manual sampling. Prototypes using the automated process have demonstrated the ability to increase the quantity and quality of data collected and have shown the potential for reducing labor and material costs for ground-water quality data collection. Automation of water-quality monitoring systems in the field, in laboratories, and in industry have increased data density and utility while reducing operating costs. Uses for an automated ground-water monitoring system include, (but are not limited to) monitoring ground-water quality for research, monitoring known or potential contaminant sites, such as near landfills, underground storage tanks, or other facilities where potential contaminants are stored, and as an early warning system monitoring groundwater quality near public water-supply wells.

  13. System and Method for Monitoring Distributed Asset Data

    NASA Technical Reports Server (NTRS)

    Gorinevsky, Dimitry (Inventor)

    2015-01-01

    A computer-based monitoring system and monitoring method implemented in computer software for detecting, estimating, and reporting the condition states, their changes, and anomalies for many assets. The assets are of same type, are operated over a period of time, and outfitted with data collection systems. The proposed monitoring method accounts for variability of working conditions for each asset by using regression model that characterizes asset performance. The assets are of the same type but not identical. The proposed monitoring method accounts for asset-to-asset variability; it also accounts for drifts and trends in the asset condition and data. The proposed monitoring system can perform distributed processing of massive amounts of historical data without discarding any useful information where moving all the asset data into one central computing system might be infeasible. The overall processing is includes distributed preprocessing data records from each asset to produce compressed data.

  14. An intelligent health monitoring system using radio-frequency identification technology.

    PubMed

    Lai, Yeong-Lin; Chen, Chin-Ling; Chang, Ching-Hisang; Hsu, Chih-Yu; Lai, Yeong-Kang; Tseng, Kuo-Kun; Chen, Chih-Cheng; Zheng, Chun-Yi

    2015-01-01

    Long-term care (LTC) for the elderly has become extremely important in recent years. It is necessary for the different physiological monitoring systems to be integrated on the same interface to help oversee and manage the elderly's needs. This paper presents a novel health monitoring system for LTC services using radio-frequency identification (RFID) technology. Dual-band RFID protocols were included in the system, in which the high-frequency (HF) band of 13.56 MHz was used to identify individuals and the microwave band of 2.45 GHz was used to monitor physiological information. Distinct physiological data, including oxyhemoglobin saturation by pulse oximetry (SpO2), blood pressure, blood sugar, electrocardiogram (ECG) readings, body temperature, and respiration rate, were monitored by various biosensors. The intelligent RFID health monitoring system provided the features of the real-time acquisition of biomedical signals and the identification of personal information pertaining to the elderly and patients in nursing homes.

  15. Effects of blind spot monitoring systems on police-reported lane-change crashes.

    PubMed

    Cicchino, Jessica B

    2018-06-21

    To examine the effectiveness of blind spot monitoring systems in preventing police-reported lane-change crashes. Poisson regression was used to compare crash involvement rates per insured vehicle year in police-reported lane-change crashes in 26 U.S. states during 2009-2015 between vehicles with blind spot monitoring and the same vehicle models without the optional system, controlling for other factors that can affect crash risk. Crash involvement rates in lane-change crashes were 14% lower (95% confidence limits -24% to -2%) among vehicles with blind spot monitoring than those without. Blind spot monitoring systems are effective in preventing police-reported lane-change crashes when considering crashes of all severities. If every U.S. vehicle in 2015 were equipped with blind spot monitoring that performed like the study systems, it is estimated that about 50,000 crashes could have been prevented.

  16. A Wireless Monitoring System for Cracks on the Surface of Reactor Containment Buildings

    PubMed Central

    Zhou, Jianguo; Xu, Yaming; Zhang, Tao

    2016-01-01

    Structural health monitoring with wireless sensor networks has been increasingly popular in recent years because of the convenience. In this paper, a real-time monitoring system for cracks on the surface of reactor containment buildings is presented. Customized wireless sensor networks platforms are designed and implemented with sensors especially for crack monitoring, which include crackmeters and temperature detectors. Software protocols like route discovery, time synchronization and data transfer are developed to satisfy the requirements of the monitoring system and stay simple at the same time. Simulation tests have been made to evaluate the performance of the system before full scale deployment. The real-life deployment of the crack monitoring system is carried out on the surface of reactor containment building in Daya Bay Nuclear Power Station during the in-service pressure test with 30 wireless sensor nodes. PMID:27314357

  17. A web-based GPS system for displacement monitoring and failure mechanism analysis of reservoir landslide.

    PubMed

    Li, Yuanyao; Huang, Jinsong; Jiang, Shui-Hua; Huang, Faming; Chang, Zhilu

    2017-12-07

    It is important to monitor the displacement time series and to explore the failure mechanism of reservoir landslide for early warning. Traditionally, it is a challenge to monitor the landslide displacements real-timely and automatically. Globe Position System (GPS) is considered as the best real-time monitoring technology, however, the accuracies of the landslide displacements monitored by GPS are not assessed effectively. A web-based GPS system is developed to monitor the landslide displacements real-timely and automatically in this study. And the discrete wavelet transform (DWT) is proposed to assess the accuracy of the GPS monitoring displacements. Wangmiao landslide in Three Gorges Reservoir area in China is used as case study. The results show that the web-based GPS system has advantages of high precision, real-time, remote control and automation for landslide monitoring; the Root Mean Square Errors of the monitoring landslide displacements are less than 5 mm. Meanwhile, the results also show that a rapidly falling reservoir water level can trigger the reactivation of Wangmiao landslide. Heavy rainfall is also an important factor, but not a crucial component.

  18. DESIGN, DEVELOPMENT, AND FIELD DEMONSTRATION OF A REMOTELY DEPLOYABLE WATER QUALITY MONITORING SYSTEM

    EPA Science Inventory

    A prototype water quality monitoring system is described which offers almost continuous in situ monitoring. The two-man portable system features: (1) a microprocessor controlled central processing unit which allows preprogrammed sampling schedules and reprogramming in situ; (2) a...

  19. Performance assessment of an onboard monitoring system for commercial motor vehicle drivers : a field operational test.

    DOT National Transportation Integrated Search

    2016-11-01

    The onboard monitoring system (OBMS) field operational test (FOT) was conducted to determine whether onboard monitoring systems that provide real-time performance feedback to commercial truck and motorcoach drivers could reduce the number of safety-c...

  20. 14 CFR 171.259 - Performance requirements: General.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... components: (1) C-Band (5000 MHz-5030 MHz) localizer equipment, associated monitor system, and remote indicator equipment; (2) C-Band (5220 MHz-5250 MHz) glide path equipment, associated monitor system, and remote indicator equipment; (3) VHF marker beacons (75 MHz), associated monitor systems, and remote...

Top