STS-40 Exp. No. 192 urine monitoring system (UMS) on OV-102's middeck
NASA Technical Reports Server (NTRS)
1991-01-01
STS-40 Experiment No. 192, Fluid-Electrolyte Regulation During Space Flight, urine monitoring system (UMS) is set up on the middeck of Columbia, Orbiter Vehicle (OV) 102, at the side hatch. The UMS is attached to OV-102's waste collection system (WCS). The urine specimen tray with sample tubes appears to the right of the UMS equipment.
NASA Technical Reports Server (NTRS)
Feedback, Daniel L.; Cibuzar, Branelle R.
2009-01-01
The Urine Monitoring System (UMS) is a system designed to collect an individual crewmember's void, gently separate urine from air, accurately measure void volume, allow for void sample acquisition, and discharge remaining urine into the Waste Collector Subsystem (WCS) onboard the International Space Station. The Urine Monitoring System (UMS) is a successor design to the existing Space Shuttle system and will resolve anomalies such as: liquid carry-over, inaccurate void volume measurements, and cross contamination in void samples. The crew will perform an evaluation of airflow at the ISS UMS urinal hose interface, a calibration evaluation, and a full user interface evaluation. o The UMS can be used to facilitate non-invasive methods for monitoring crew health, evaluation of countermeasures, and implementation of a variety of biomedical research protocols on future exploration missions.
Single Pass Stripline Beam Position Monitor Design, Fabrication and Commissioning
NASA Astrophysics Data System (ADS)
Tan, Y.-R. E.; Wang, D.; Van Garderen, E.; McKinlay, J.
2012-10-01
To monitor the position of the electron beam during transport from the Booster Synchrotron to the Storage Ring at the Australian Synchrotron, a stripline Beam Position Monitor (BPM) has been designed, fabricated and installed in-house. The design was based on an existing stripline in the Booster and modified for the transfer line with a particular emphasis on ensuring the line impedance is properly matched to the detector system. The initial bench tests of a prototype stripline showed that the fabrication of the four individual striplines in the BPM was made precisely, each with a measured standing wave ratio (SWR) of 1.8 at 500 MHz. Further optimization for impedance matching will be done for new stripline BPMs. The linearity and gain factor was measured with the detector system. The detector system that digitizes the signals is an Instrumentation Technologies Brilliance Single Pass [1]. The results show an error of 1 mm at an offset (from the electrical centre) of 10 mm when a linear gain factor is assumed and an RMS noise of ~150 um that decreases to < 10 um with increasing signal intensity. The results were under our requirements for the transport line. The commissioning results of the stripline will also be presented showing a strong signal for an electron beam with an estimated integrated charge of ~50 nC with a position stability of 28 um (horizontal) and 75 um (vertical).
STS-40 Exp. No. 192 urine monitoring system (UMS) on OV-102's middeck
1991-06-14
STS040-04-036 (5-14 June 1991) --- Closeup view of urine monitoring system and test samples, part of the busy schedule of life sciences testing on the nine-day STS-40/Spacelab Life Sciences (SLS-1) mission aboard the earth-orbiting Columbia.
Development of an Inline Urine Monitoring System for the International Space Station
NASA Technical Reports Server (NTRS)
Broyan, James Lee, Jr.; Cibuzar, Banelle R.
2008-01-01
Human exposure to microgravity during spaceflight causes bone loss. Calcium and other metabolic byproducts are excreted in urine voids. Frequent and accurate measurement of urine void volume and constituents is essential to determining crew bone loss and the effectiveness of countermeasures. Previous US Space Shuttle (SS) Urine Monitoring System (UMS) technology was unable to accurately measure urine void volumes due to cross contamination between users and fluid system instabilities. Currently, urine voids must be collected manually in a flexible plastic bag containing a known tracer quantity. The crew member must completely mix the bag then withdraw a representative syringe sample for later ground analysis. The current bag system accuracy is highly dependent on mixing technique. The International Space Station (ISS) UMS has been developed as an automated device that collects urine from the Waste and Hygiene Compartment (WHC) urinal funnel interface, separates the urine, measures the void volume, and allows for syringe sampling. After operations, the ISS UMS delivers the urine to the WHC for normal processing then flushes its plumbing with a small water volume. The current ISS UMS design incorporates an innovative rotary separator that minimizes foaming, greatly reduces cross contamination between urine voids (< 0.5 ml urine), and provides accurate volume measurements (< +/- 2% error for 100 to 1000 ml void volumes). The system performance has been validated with extensive ground tests and reduced gravity aircraft flights. The lockersized ISS UMS is currently being modified to interface with the ISS Node 3 WHC Russian ACY hardware. The operation principles, characteristics, and results are outlined in the paper.
The International Space Station Urine Monitoring System (UMS)
NASA Technical Reports Server (NTRS)
Feeback, Daniel L.; Cibuzar, Branelle R.; Milstead, Jeffery R.; Pietrzyk,, Robert A.; Clark, Mark S.F.
2009-01-01
A device capable of making in-flight volume measurements of single void urine samples, the Urine Monitoring System (UMS), was developed and flown on seven U.S. Space Shuttle missions. This device provided volume data for each urine void from multiple crewmembers and allowed samples of each to be taken and returned to Earth for post-flight analysis. There were a number of design flaws in the original instrument including the presence of liquid carry-over producing invalid "actual" micturition volumes and cross-contamination between successive users from residual urine in "dead" spots". Additionally, high or low volume voids could not be accurately measured, the on-orbit calibration and nominal use sequence was time intensive, and the unit had to be returned and disassembled to retrieve the volume data. These problems have been resolved in a new version, the International Space Station (ISS) UMS, that has been designed to provide real-time in-flight volume data with accuracy and precision equivalent to measurements made on Earth and the ability to provide urine samples that are unadulterated by the device. Originally conceived to be interfaced with a U.S.-built Waste Collection System (WCS), the unit now has been modified to interface with the Russian-supplied Sanitary Hygiene Device (ASY). The ISS UMS provides significant advantages over the current method of collecting urine samples into Urine Collection Devices (UCDs), from which samples are removed and returned to Earth for analyses. A significant future advantage of the UMS is that it can provide an interface to analytical instrumentation that will allow real-time measurement of urine bioanalytes allowing monitoring of crewmember health status during flight and the ability to provide medical interventions based on the results of these measurements. Currently, the ISS UMS is scheduled to launch along with Node-3 on STS-130 (20A) in December 2009. UMS will be installed and scientific/functional verification completed prior to placing the instrument into operation. Samples collected during the verification sequence will be returned for analyses on STS-131 (19A) currently scheduled for launch in March 2010. The presence of a UMS on ISS will provide the capability to conduct additional collaborative human life science investigations among the ISS International Partners.
Development of an In-line Urine Monitoring System for the International Space Station
NASA Technical Reports Server (NTRS)
Broyan, James Lee, Jr.; Cibuzar, Branelle R.
2009-01-01
Exposure to microgravity during space flight causes bone loss when calcium and other metabolic by-products are excreted in urine voids. Frequent and accurate measurement of urine void volume and constituents is thus essential in determining crew bone loss and the effectiveness of the countermeasures that are taken to minimize this loss. Earlier space shuttle Urine Monitoring System (UMS) technology was unable to accurately measure urine void volumes due to the cross-contamination that took place between users, as well as to fluid system instabilities. Crew urine voids are currently collected manually in a flexible plastic bag that contains a known tracer quantity. A crew member must completely mix the contents of this bag before withdrawing a representative syringe sample for later ground analysis. The existing bag system accuracy is therefore highly dependent on mixing technique. The International Space Station (ISS) UMS has been developed as an automated device that collects urine from the Waste and Hygiene Compartment (WHC) urinal funnel interface, separates the urine, measures void volume, and allows for syringe sampling. After the ISS UMS has been used by a crew member, it delivers urine to the WHC for normal processing. The UMS plumbing is then flushed with a small volume of water. The current ISS UMS design incorporates an innovative rotary separator that minimizes foaming, consequently greatly reducing cross-contamination among urine voids (less than 0.5 mL urine) while also providing accurate volume measurements (less than 2 percent error for 100 to 1,000 mL void volumes). ISS UMS performance has been validated through extensive ground tests and reduced-gravity aircraft flights. The locker-sized ISS UMS is currently undergoing a design modification that will permit it to interface with the ISS Node 3 WHC Russian toilet (ACY) hardware. The operating principles, characteristics, and results of this design modification are outlined here.
International Space Station Urine Monitoring System Functional Integration and Science Testing
NASA Technical Reports Server (NTRS)
Rodriquez, Branelle R.; Broyan, James Lee, Jr.
2011-01-01
Exposure to microgravity during human spaceflight needs to be better understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Measuring the calcium and other metabolic byproducts in a crew member s urine can evaluate the effectiveness of bone loss countermeasures. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross-contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross-contamination (<0.7 mL urine) and has volume accuracy of 2% between 100 to 1000 mL urine voids. Designed to provide a non-invasive means to collect urine samples from crew members, the ISS UMS operates in-line with the Node 3 Waste and Hygiene Compartment (WHC). The ISS UMS has undergone modifications required to interface with the WHC, including material changes, science algorithm improvements, and software platform revisions. Integrated functional testing was performed to determine the pressure drop, air flow rate, and the maximum amount of fluid capable of being discharged from the UMS to the WHC. This paper will detail the results of the science and the functional integration tests.
BME Estimation of Residential Exposure to Ambient PM10 and Ozone at Multiple Time Scales
Yu, Hwa-Lung; Chen, Jiu-Chiuan; Christakos, George; Jerrett, Michael
2009-01-01
Background Long-term human exposure to ambient pollutants can be an important contributing or etiologic factor of many chronic diseases. Spatiotemporal estimation (mapping) of long-term exposure at residential areas based on field observations recorded in the U.S. Environmental Protection Agency’s Air Quality System often suffer from missing data issues due to the scarce monitoring network across space and the inconsistent recording periods at different monitors. Objective We developed and compared two upscaling methods: UM1 (data aggregation followed by exposure estimation) and UM2 (exposure estimation followed by data aggregation) for the long-term PM10 (particulate matter with aerodynamic diameter ≤ 10 μm) and ozone exposure estimations and applied them in multiple time scales to estimate PM and ozone exposures for the residential areas of the Health Effects of Air Pollution on Lupus (HEAPL) study. Method We used Bayesian maximum entropy (BME) analysis for the two upscaling methods. We performed spatiotemporal cross-validations at multiple time scales by UM1 and UM2 to assess the estimation accuracy across space and time. Results Compared with the kriging method, the integration of soft information by the BME method can effectively increase the estimation accuracy for both pollutants. The spatiotemporal distributions of estimation errors from UM1 and UM2 were similar. The cross-validation results indicated that UM2 is generally better than UM1 in exposure estimations at multiple time scales in terms of predictive accuracy and lack of bias. For yearly PM10 estimations, both approaches have comparable performance, but the implementation of UM1 is associated with much lower computation burden. Conclusion BME-based upscaling methods UM1 and UM2 can assimilate core and site-specific knowledge bases of different formats for long-term exposure estimation. This study shows that UM1 can perform reasonably well when the aggregation process does not alter the spatiotemporal structure of the original data set; otherwise, UM2 is preferable. PMID:19440491
International Space Station Urine Monitoring System Functional Integration and Science Testing
NASA Technical Reports Server (NTRS)
Rodriguez, Branelle R.; Broyan, James Lee, Jr.
2008-01-01
Exposure to microgravity during human spaceflight is required to be defined and understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Urine voids are capable of measuring the calcium and other metabolic byproducts in a constituent s urine. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross contamination (<0.7 ml urine) and has volume accuracy of +/-2% between 100 to 1000 ml urine voids.
International Space Station Urine Monitoring System Functional Integration and Science Testing
NASA Technical Reports Server (NTRS)
Cibuzar, Branelle R.; Broyan, James Lee, Jr.
2009-01-01
Exposure to microgravity during human spaceflight is required to be defined and understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Urine voids are capable of measuring the calcium and other metabolic byproducts in a constituent s urine. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross contamination (<0.7 ml urine) and has volume accuracy of +/-2% between 100 to 1000 ml urine voids.
Urine monitoring system failure analysis and operational verification test report
NASA Technical Reports Server (NTRS)
Glanfield, E. J.
1978-01-01
Failure analysis and testing of a prototype urine monitoring system (UMS) are reported. System performance was characterized by a regression formula developed from volume measurement test data. When the volume measurement test data. When the volume measurement data was imputted to the formula, the standard error of the estimate calculated using the regression formula was found to be within 1.524% of the mean of the mass of the input. System repeatability was found to be somewhat dependent upon the residual volume of the system and the evaporation of fluid from the separator. The evaporation rate was determined to be approximately 1cc/minute. The residual volume in the UMS was determined by measuring the concentration of LiCl in the flush water. Observed results indicated residual levels in the range of 9-10ml, however, results obtained during the flushing efficiency test indicated a residual level of approximately 20ml. It is recommended that the phase separator pumpout time be extended or the design modified to minimize the residual level.
In vivo monitoring of nanosphere onsite delivery using fiber optic microprobe
NASA Astrophysics Data System (ADS)
Lo, Leu-Wei; Yang, Chung-Shi
2005-02-01
To recognize the information of ischemia-induced blood vessel permeability would be valuable to formulate the drugs for optimal local delivery, we constructed an implantable needle type fiber-optic microprobe for the monitoring of in vivo fluorescent substances in anesthetized rats. This fiber-optic microprobe was composed of coaxial optical fibers and catheterized using a thin wall tubing of stainless steel (~400 um O.D. and ~300 um I.D.). The central fiber, with 100 um core diameter and 20 um cladding, coated with a 30 um layer of gold, was surrounded by 10 fibers with 50 um cores. The central fiber carried the light from the 488 nm Argon laser to the tissue while the surrounding fibers collected the emitted fluorescence to the detector. When the fiber-optic microprobe was placed in the solutions containing various concentrations of fluorescent nanospheres (20 nm), either with or without 10% lipofundin as optical phantom, nanosphere concentration-dependent responses of the fluorescence intensity were observed. The microprobe was then implanted into the liver and the brain of anesthetized rats to monitor the in situ extravasation of pre-administered fluorescent nanospheres from vasculature following the ischemic insults. Both the hepatic and cerebral ischemic insults showed immediate increases of the extracellular 20 nm fluorescent nanospheres. The implantable fiber-optic microprobe constructed in present study provides itself as a minimally-invasive technique capable of investigating the vascular permeability for in vivo nanosphere delivery in both ischemic liver and brain.
1994-04-01
1 lfm ýA a I - @0 38Ud U 0 E loll I0 F4J O 3Uv ~:~3 Igaas .1c % jWC (9 Um IDP. 0 di d0 1.00 00 .d .d d V d d~ di dI C-14 rM D0209- II dUmW o iNc cl...5C15-1 (In River) I FIGURE E-6. MEASUREMENT POINT AT TRANSMISSION UNE; 5C15-1. E-9 IITRI D06209-1 I I 0CS I C .00o tD I I- U, I S IcEoE 0 E0 a-0
An RFID-based on-lens sensor system for long-term IOP monitoring.
Hsu, Shun-Hsi; Chiou, Jin-Chern; Liao, Yu-Te; Yang, Tzu-Sen; Kuei, Cheng-Kai; Wu, Tsung-Wei; Huang, Yu-Chieh
2015-01-01
In this paper, an RFID-based on-lens sensor system is proposed for noninvasive long-term intraocular pressure monitoring. The proposed sensor IC, fabricated in a 0.18um CMOS process, consists of capacitive sensor readout circuitry, RFID communication circuits, and digital processing units. The sensor IC is integrated with electroplating capacitive sensors and a receiving antenna on the contact lens. The sensor IC can be wirelessly powered, communicate with RFID compatible equipment, and perform IOP measurement using on-lens capacitive sensor continuously from a 2cm distance while the incident power from an RFID reader is 20 dBm. The proposed system is compatible to Gen2 RFID protocol, extending the flexibility and reducing the self-developed firmware efforts.
Hammoud, Abbas; Chamseddine, Ahmad; Nguyen, Dang K; Sawan, Mohamad
2016-08-01
The need of continuous real-time monitoring device for in-vivo drug level detection has been widely articulated lately. Such monitoring could guide drug posology and timing of intake, detect low or high drug levels, in order to take adequate measures, and give clinicians a valuable window into patients' health and their response to therapeutics. This paper presents a novel implantable bio-sensor based on impedance measurement capable of continuously monitoring various antiepileptic drug levels. This portable point-of-care microsystem replaces large and stationary conventional macrosystems, and is a one of a kind system designed with an array of electrodes to monitor various anti-epileptic drugs rather than one drug. The micro-system consists of (i) the front-end circuit including an inductive coil to receive energy from an external base station, and to exchange data with the latter; (ii) the power management block; (iii) the readout and control block; and (iv) the biosensor array. The electrical circuitry was designed using the 0.18-um CMOS process technology intended to be miniature and consume ultra-low power.
Active Time-Domain Reflectometry for Unattended Safeguards Systems: FY16 Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tedeschi, Jonathan R.; Smith, Leon E.; Conrad, Ryan C.
2016-10-21
The International Atomic Energy Agency (IAEA) continues to expand its use of unattended measurement systems. An increasing number of systems and an expanding family of instruments create challenges in terms of deployment efficiency and the implementation of data authentication measures. Traditional data security measures, for example tamper-indicating (TI) conduit, are impractical for the long separation distances (often 100 meters or more) between unattended monitoring system (UMS) components. Pacific Northwest National Laboratory (PNNL) is studying the viability of active time-domain reflectometry (TDR) for the detection of cable tampering in unattended radiation detection systems. The instrument concept under investigation would allow formore » unmanned cable integrity measurements, remote surveillance reporting and locating of cable faults and/or tampers. This report describes PNNL’s FY16 progress and includes: an overview of the TDR methods under investigation; description of the TDR evaluation testbed developed by PNNL; development and testing of advanced signal processing algorithms to extract weak signals from relatively high noise levels; and initial testing of a laboratory prototype intended for IAEA UMS applications and based on a commercially available TDR module. Preliminary viability findings and recommendations for the next stage of development and testing are provided.« less
NASA Astrophysics Data System (ADS)
Terroux, Marc; Marchese, Linda; Bolduc, Martin; Mercier, Luc; Chevalier, Claude; Gagnon, Lucie; Tremblay, Bruno; Généreux, Francis; Paultre, Jacques-Edmond; Provençal, Francis; Beaupré, Patrick; Desroches, Yan; Châteauneuf, François; Bergeron, Alain
2017-11-01
In the past, bolometer-based imagers have been used for earth observation. Uncooled-bolometer based imagers are especially well suited for this due to their low power consumption. NIRST (New Infra-Red Sensor Technology), an example of an imager based on uncooled bolometers, monitors high temperature events on the ground related to fires and volcanic events, and will measure their physical parameters and takes measurements of sea surface temperatures mainly off the coast of South America as well as other targeted opportunities. NIRST has one band in the mid-wave infrared centered at 3.8 um with a bandwidth of 0.8 um, and two bands in the thermal infrared, centered respectively at 10.85 and 11.85 um with a bandwidth of 0.9 um.
Wallace, Lorraine S; Keenum, Amy J
2008-08-01
To evaluate the readability and related features of English language Quick Reference Guides (QRGs) and User Manuals (UMs) accompanying home blood pressure monitors (HBPMs). We evaluated QRGs and UMs for 22 HBPMs [arm (n=12); wrist (n=10)]. Using established criteria, we evaluated reading grade level, language availability, dimensions, text point size, use of illustrations, layout/formatting characteristics, and emphasis of key points of English-language patient instructions accompanying HBPMs. Readability was calculated using McLaughlin's Simplified Measure of Gobbledygoop. Items from the Suitability of Materials Assessment and User-Friendliness Tool were used to assess various layout features. Simplified Measure of Gobbledygoop scores of both QRGs (mean+/-SD=9.1+/-0.8) and UMs (9.3+/-0.8) ranged from 8th to 10th grade. QRGs and UMs presented steps in chronological order, used active voice throughout, avoided use of specialty fonts, focused on need to know, and used realistic illustrations. Seven sets of instructions included all seven key points related to proper HPBM use, whereas three sets of instructions included less than or equal to three key points (mean=4.8+/-1.9). Although most QRGs and UMs met at least some recommended low-literacy formatting guidelines, all instructional materials should be developed and tested to meet the needs of the patient population at large. Key points related to proper HBPM use should not only be included within these instructions, but highlighted to emphasize their importance.
NASA Astrophysics Data System (ADS)
La Valle, F. F.; Thomas, F. I. M.
2016-02-01
As populations grow and development efforts continue in coastal regions throughout the world, eutrophication is one of the leading issues surrounding coastal ecosystems. Currently, studies on subterranean groundwater discharge (SGD) are confirming that SGD can contain substantial nutrient concentrations due to agricultural activities, urbanization, leaky septic and sewer systems, and use of fertilizers. Thus, it is important for SGD with high nutrient concentrations to be monitored for its impact on coastal dynamics. Coral reef systems are especially sensitive to changes in nutrient concentrations which can change community composition by creating advantageous biochemical environments for specific algal species. Excess nutrients along with decreased herbivory have been attributed to phase shifts from coral dominated to algal dominated reefs. In this study we mapped algal cover and nutrient load with respect to the groundwater in two fringing reefs (Black Point and Wailupe) in Maunalua Bay, Oahu, Hawaíi. We established relationships between salinity and nutrient concentrations for the two sites by sampling synoptically on an onshore to offshore transect from the SGD seeps (n = 48 Black Point, n = 40 Wailupe, R2 > 0.965). The groundwater end members at the two sites have different nutrient signatures: concentrations at Black Point averaged 167.3 uM N+N (NO3- + NO2-) and 3.57 uM PO43-, while at Wailupe nutrient concentrations averaged 68.7 uM N+N and 1.96 uM PO43-. We used these relationships to calculate nutrient time series after deploying 23 autonomous salinity sensors for one month across the benthos at each site respectively. Benthic surveys taken over 2 seasons indicate that the algal composition and distribution relative to the groundwater sources differ at the two sites. Growth rates of some major macroalgal species also differ with distance from SGD source. Further studies on the biological effects of high SGD-associated nutrients on coastal systems are warranted.
Park, Chul Soon; Ha, Tai Hwan; Kim, Moonil; Raja, Naren; Yun, Hui-Suk; Sung, Mi Jeong; Kwon, Oh Seok; Yoon, Hyeonseok; Lee, Chang-Soo
2018-05-15
Alkaline phosphatase (ALP) is a critical biological marker for osteoblast activity during early osteoblast differentiation, but few biologically compatible methods are available for its detection. Here, we describe the discovery of highly sensitive and rapidly responsive novel near-infrared (NIR) fluorescent probes (NIR-Phos-1, NIR-Phos-2) for the fluorescent detection of ALP. ALP cleaves the phosphate group from the NIR skeleton and substantially alters its photophysical properties, therefore generating a large "turn-on" fluorescent signal resulted from the catalytic hydrolysis on fluorogenic moiety. Our assay quantified ALP activity from 0 to 1.0UmL -1 with a 10 -5 -10 -3 UmL -1 limit of detection (LOD), showing a response rate completed within 1.5min. A potentially powerful approach to probe ALP activity in biological systems demonstrated real-time monitoring using both concentration- and time-dependent variations of endogenous ALP in live cells and animals. Based on high binding affinity to bone tissue of phosphate moiety, bone-like scaffold-based ALP detection in vivo was accessed using NIR probe-labeled three-dimensional (3D) calcium deficient hydroxyapatite (CDHA) scaffolds. They were subcutaneously implanted into mice and monitored ALP signal changes using a confocal imaging system. Our results suggest the possibility of early-stage ALP detection during neo-bone formation inside a bone defect, by in vivo fluorescent evaluation using 3D CDHA scaffolds. Copyright © 2018 Elsevier B.V. All rights reserved.
Mid-infrared Flux Variability in an Awakening AGN
NASA Astrophysics Data System (ADS)
Yeh, Sherry
We propose FORCAST spectroscopic observations between 8 um to 40 um near the nucleus of NGC 660. NGC 660 underwent an AGN outburst 6 years ago, which is an ideal case for studying AGN astrophysics in a rather quiecent system. However, this rare event has not yet been monitored. Our immidiate goal is to verify the MIR spectroscipic variabilitiy in NGC 660, and to study the AGN effects on dust destruction and ISM. We will compare the FORCAST spectra with the Spitzer IRS spectra (taken before the AGN outburst), including dust continuum, PAH emission, and high- and low-ionization emission lines. FORCAST's slit width is a close match to the IRS slit width, allowing a direct comparison of the spectra between FORCAST and IRS. Our single-slit Subaru COMICS spectrum taken after the outburst shows significantly weakened PAH emission and dust continuum, suggesting dust destruction. However, it is difficult to draw robust intepretations due to systematic uncertainties in the Subaru data. If dust destruction is confirmed in the post-outburst FORCAST observaitons, we will evaluate the energy budget using the MIR line ratio diagnostics, with archival X-ray and radio data. We will then propose cadence observations of MGC 660's nucleus to monitor the MIR flux variability, and employ the reverberation mapping technique to study NGC 660's AGN.
Active depth-guiding handheld micro-forceps for membranectomy based on CP-SSOCT
NASA Astrophysics Data System (ADS)
Cheon, Gyeong Woo; Lee, Phillip; Gonenc, Berk; Gehlbach, Peter L.; Kang, Jin U.
2016-03-01
In this study, we demonstrate a handheld motion-compensated micro-forceps system using common-path swept source optical coherence tomography with highly accurate depth-targeting and depth-locking for Epiretinal Membrane Peeling. Two motors and a touch sensor were used to separate the two independent motions: motion compensation and tool-tip manipulation. A smart motion monitoring and guiding algorithm was devised for precise and intuitive freehand control. Ex-vivo bovine eye experiments were performed to evaluate accuracy in a bovine retina retinal membrane peeling model. The evaluation demonstrates system capabilities of 40 um accuracy when peeling the epithelial layer of bovine retina.
Injection-depth-locking axial motion guided handheld micro-injector using CP-SSOCT.
Cheon, Gyeong Woo; Huang, Yong; Kwag, Hye Rin; Kim, Ki-Young; Taylor, Russell H; Gehlbach, Peter L; Kang, Jin U
2014-01-01
This paper presents a handheld micro-injector system using common-path swept source optical coherence tomography (CP-SSOCT) as a distal sensor with highly accurate injection-depth-locking. To achieve real-time, highly precise, and intuitive freehand control, the system used graphics processing unit (GPU) to process the oversampled OCT signal with high throughput and a smart customized motion monitoring control algorithm. A performance evaluation was conducted with 60-insertions and fluorescein dye injection tests to show how accurately the system can guide the needle and lock to the target depth. The evaluation tests show our system can guide the injection needle into the desired depth with 4.12 um average deviation error while injecting 50 nl of fluorescein dye.
DEVELOPMENT AND EVALUATION OF A CONTINUOUS COARSE (PM10-PM2.5) PARTICLE MONITOR
In this paper, we describe the development and laboratory and field evaluation of a continuous coarse (2.5-10 um) particle mass (PM) monitor that can provide reliable measurements of the coarse mass (CM) concentrations in time intervals as short as 5-10 min. The operating princ...
1982-09-30
OF TI4IS PIAGE(,,aW Date Eateed) cont. block 20: .... differential wheelwear and thereby prevent form errors. Wheel sharpness can also be monitored to...80 5. NOMENCLATURE V = Work surface speed (m/s) w Nw = Work speed (RPM) Vs = Wheel surface speed (m/sec) Ns = Wheel ...speed (RPM) Vt = Traverse speed (m/sec) 0 = Work diameter (mm)W D = Wheel diameter (mm) z= Dress lead (um/rev) c = 2*diamond depth-of-dress (um) d
NASA Astrophysics Data System (ADS)
Zhi, Zhongwei; Jung, Yeongri; Jia, Yali; An, Lin; Wang, Ruikang K.
2011-03-01
We present a non-invasive, label-free imaging technique called Ultrahigh Sensitive Optical Microangiography (UHSOMAG) for high sensitive volumetric imaging of renal microcirculation. The UHS-OMAG imaging system is based on spectral domain optical coherence tomography (SD-OCT), which uses a 47000 A-line scan rate CCD camera to perform an imaging speed of 150 frames per second that takes only ~7 seconds to acquire a 3D image. The technique, capable of measuring slow blood flow down to 4 um/s, is sensitive enough to image capillary networks, such as peritubular capillaries and glomerulus within renal cortex. We show superior performance of UHS-OMAG in providing depthresolved volumetric images of rich renal microcirculation. We monitored the dynamics of renal microvasculature during renal ischemia and reperfusion. Obvious reduction of renal microvascular density due to renal ischemia was visualized and quantitatively analyzed. This technique can be helpful for the assessment of chronic kidney disease (CKD) which relates to abnormal microvasculature.
Size Distribution and First Flush Effects of Mercury Containing Particles in Highway Runoff Water
NASA Astrophysics Data System (ADS)
Ferguson, K.; Green, P.
2007-12-01
Human and environmental health concerns have recently prompted many California water quality control boards to lower the Total Maximum Daily Loads (TMDL) of Mercury into their water systems. A size distribution study of mercury containing particles was conducted in order to begin to understand the possible sources of the contamination in highway storm water runoff. Four storms were studied from a monitoring site in the Los Angeles area near the crossing of highways 605 and 91. Storm water ran through an extended detention basin made of earthen material with a maximum water depth of 1.17m. Grab samples were collected manually starting at the beginning of the runoff, continuing at every fifteen minutes for the first hour, followed by a collection every hour after that for the duration of the storm. The particle sizes were separated into five size ranges (larger than 100um, 20-100um, 8-20um, 0.45-8um, and 0-0.45um) by sequential filtration. The samples were then acid digested for further analysis. Five standard Mercury solutions ranging from 5 to 100 parts per trillion were prepared in nitric acid immediately before analysis. Samples were analyzed for both the Hg-199 and the Hg-202 isotopes using an Agilent 7500i Inductively Coupled Plasma Mass Spectrometer. Substantial sub-micron concentrations of mercury were detected from all four storms, and in all five particle size ranges studied. The total amount of Mercury detected from each of the storms ranged from 8.5 to 35.5 pptr. Bursts of rain correlate well with increases of influent Hg concentration. Although a First Flush effect can be seen in the first storm, it is not as strong and/or not shown at all in the remaining three. The detention basin used at the site was shown to be an efficient BMP, reducing the amount of Hg in the effluent runoff as much as 30 pptr and down to as little as 2 pptr. The majority of Hg was found in either the 8-20um or the 0-0.45um particle size ranges. Mitigation of either portion will be challenging, but necessary to meet proposed 50 percent reductions.
UM-PRS: An implementation of the procedural reasoning system for multirobot applications
NASA Technical Reports Server (NTRS)
Lee, Jaeho; Huber, Marcus J.; Durfee, Edmund H.; Kenny, Patrick G.
1994-01-01
The Procedural Reasoning System (PRS) is used in applications where predetermined situations might arise. The UM-PRS provides a reasoning system that represents robotic applications even in unpredictable domains, such as the robotic reconnaissance task domain outlined here. UM-PRS incorporates a changing context, rather than relying solely on a prearranged plan. The UM-PRS here provides representation important in the reasoning and interface between a mission plan and the executable map of an outdoor vehicle that changes its behavior based on what it comes in contact with in its environment. PRS is thus used in the dynamic control of such a vehicle, providing the basis for coordinating the joint task of multiple robotic vehicles by the their individual observations and representation.
Design of the SAC-D/NIRST camera module
NASA Astrophysics Data System (ADS)
Gauvin, Jonny; Châteauneuf, François; Marchese, Linda; Coté, Patrice; Leclerc, Mélanie; Chevalier, Claude; Marraco, Hugo; Phong, Linh N.
2007-09-01
Aquarius/SAC-D is a cooperative international mission conducted jointly by the National Aeronautics and Space Administration (NASA) of the United States of America (USA) and the Comisión Nacional de Actividades Espaciales (CONAE) of Argentina. The overall mission targets the understanding of the total Earth system and the consequences of the natural and man-made changes in the environment of the planet. Jointly developed by CONAE and the Canadian Space Agency (CSA), the New IR Sensor Technology (NIRST) instrument will monitor high temperature events on the ground related to fires and volcanic events, and will measure their physical parameters. Furthermore, NIRST will take measurements of sea surface temperatures mainly off the coast of South America as well as other targeted opportunities. NIRST has one band in the mid-wave infrared centered at 3.8 um with a bandwidth of 0.8 um, and two bands in the thermal infrared, centered respectively at 10.85 and 11.85 um with a bandwidth of 0.9 um. The temperature range is from 300 to 600 K with an NEDT < 0.5 K for the mid-infrared band and from 200 to 400 K with an NEDT < 0.4 K for the thermal bands. The baseline design of the NIRST is based on micro-bolometer technology developed jointly by INO and the CSA. Two arrays of 512x3 uncooled bolometric sensors will be used to measure brightness temperatures. The instantaneous field-of-view is 534 microradians corresponding to a ground sampling distance of 350 m at the subsatellite point. A pointing mirror allows a total swath of +/- 500 km. This paper describes the detailed design of the NIRST camera module. Key performance parameters are also presented.
Short-range lidar for bioagent detection and classification
NASA Astrophysics Data System (ADS)
Hô, Nicolas; Émond, Frédéric; Babin, François; Healy, Dave; Simard, Jean-Robert; Buteau, Sylvie; McFee, John E.
2010-04-01
We have developed a small, relatively lightweight and efficient short range (<100 m) LIDAR instrument for remotely detecting harmful bioagents. The system is based on a pulsed, eye-safe, 355 nm laser exciting aerosols which then fluoresce with a typical spectrum. The system makes use of a novel technology for continuously monitoring for the presence of unusual concentrations of bioaerosols at a precise remote location within the monitored area, with response within seconds. Fluorescence is spectrally resolved over 32 channels capable of photon counting. Results show a sensitivity level of 40 ACPLA of Bacillus Globigii, an anthrax simulant, at a distance of 100 m (assumed worst case where 1 ppl = 1 ACPLA) considering particle sizes between 0.5 and 10 μm, with a geometric mean at 1 um. The apparatus has been tested in the field during three test and evaluation campaigns with multiple bioagents and public security products. Preliminary results show that the system is able to distinguish between harmful bioagents and naturally occurring ones. A classification algorithm was successfully tested with a single type of bioagent; experiments for daytime measurements are discussed.
Cheng, H W; Jeng, B M; Chen, C Y; Huang, H Y; Chiou, J C; Luo, C H
2013-01-01
This paper proposed a wireless power harvesting system with micro-electro-mechanical-systems (MEMS) fabrication for noninvasive intraocular pressure (IOP) measurement on soft contact lens substructure. The power harvesting IC consists of a loop antenna, an impedance matching network and a rectifier. The proposed IC has been designed and fabricated by CMOS 0.18 um process that operates at the ISM band of 5.8 GHz. The antenna and the power harvesting IC would be bonded together by using flip chip bonding technologies without extra wire interference. The circuit utilized an impedance transformation circuit to boost the input RF signal that improves the circuit performance. The proposed design achieves an RF-to-DC conversion efficiency of 35% at 5.8 GHz.
2010-06-01
QCM Quartz Crystal Deposition Monitor SEM Scanning Electron Microscope SRF Superconducting Radio Frequency T Torr Ti Titanium UHV Ultra...High Vacuum ( -7 Torr) UM University of Maryland QCM Quartz Crystal Deposition Monitor V Volt VAC Voltage-Alternating Current xvii...event. The two originally had problems with their tungsten filaments crystallizing and breaking. Being experimentalists, they added thorium in an
Evaluation of Laser Stabilization and Imaging Systems for LCLS-II - Final Paper
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barry, Matthew
2015-08-20
By combining the top performing commercial laser beam stabilization system with the most ideal optical imaging configuration, the beamline for the Linear Accelerator Coherent Light Source II (LCLS-II) will deliver the highest quality and most stable beam to the cathode. To determine the optimal combination, LCLS-II beamline conditions were replicated and the systems tested with a He-Ne laser. The Guidestar-II and MRC active laser beam stabilization systems were evaluated for their ideal positioning and stability. Both a two and four lens optical imaging configuration was then evaluated for beam imaging quality, magnification properties, and natural stability. In their best performancesmore » when tested over fifteen hours, Guidestar-II kept the beam stable over approximately 70-110um while the MRC system kept it stable over approximately 90-100um. During short periods of time, Guidestar-II kept the beam stable between 10-20um, but was more susceptible to drift over time, while the MRC system maintained the beam between 30-50um with less overall drift. The best optical imaging configuration proved to be a four lens system that images to the iris located in the cathode room and from there, imaged to the cathode. The magnification from the iris to the cathode was 2:1, within an acceptable tolerance to the expected 2.1:1 magnification. The two lens configuration was slightly more stable in small periods of time (less than 10 minutes) without the assistance of a stability system, approximately 55um compared to approximately 70um, but the four lens configurations beam image had a significantly flatter intensity distribution compared to the two lens configuration which had a Gaussian distribution. A final test still needs to be run with both stability systems running at the same time through the four lens system. With this data, the optimal laser beam stabilization system can be determined for the beamline of LCLS-II.« less
Bhavsar, Preetish; Rathod, Kirtikumar Jagdish; Rathod, Darshana; Chamania, C S
2013-02-01
Rhabdomyolysis due to trauma and burns is an important cause of acute renal failure (ARF) secondary to myoglobinuria. To prevent morbidity and mortality from ARF due to rhabdomyolysis, early detection of ARF by monitoring the biochemical parameters such as serum creatinine, serum creatine kinase (CK), and urinary myoglobin (UM) can be helpful. The aims of the study were (1) to detect ARF due to rhabdomyolysis using serum creatinine, serum CK, and UM in trauma and electrical burn patients (2) to compare utility of these parameters in early prediction of ARF in patients of rhabdomyolysis. A total of 50 patients with trauma and electrical burns were included in the study. Serum creatinine, serum CK, and UM measurements were done at the time of admission and after 48 h. Diagnosis of ARF was made in the patients by Rifle's criteria. The presence of significant elevation of creatinine, serum CK, and UM at the time of admission and after 48 h was compared in patients developing ARF by Fisher's exact test. Fifteen of the 50 patients developed ARF as per the defined criteria. Of these, 9 patients (60 %) had raised level of serum creatinine above 1.4 mg% at admission and 14 patients (93.33 %) had CK level >1250 U/L at admission, whereas UM was positive in 6 (40 %) patients. Serum creatinine was significantly raised in all of the 15 ARF patients (100 %) after 48 h of admission and serum CK was raised in 14 of the 15 ARF patients (93.33 %). UM was negative in all the patients after 48 h of admission. Statistical analysis showed that rise in serum CK on admission was significantly increased in patients developing ARF as compared with serum creatinine and UM (P < 0.0001). On admission, CK is a better predictor of ARF due to rhabdomyolysis than creatinine and UM. Initial creatinine is a better predictor of ARF due to rhabdomyolysis than UM. UM assay is not a good investigation for early prediction of ARF in rhabdomyolysis.
NASA Astrophysics Data System (ADS)
Durst, Phillip J.; Gray, Wendell; Trentini, Michael
2013-05-01
A simple, quantitative measure for encapsulating the autonomous capabilities of unmanned systems (UMS) has yet to be established. Current models for measuring a UMS's autonomy level require extensive, operational level testing, and provide a means for assessing the autonomy level for a specific mission/task and operational environment. A more elegant technique for quantifying autonomy using component level testing of the robot platform alone, outside of mission and environment contexts, is desirable. Using a high level framework for UMS architectures, such a model for determining a level of autonomy has been developed. The model uses a combination of developmental and component level testing for each aspect of the UMS architecture to define a non-contextual autonomous potential (NCAP). The NCAP provides an autonomy level, ranging from fully non- autonomous to fully autonomous, in the form of a single numeric parameter describing the UMS's performance capabilities when operating at that level of autonomy.
NASA Astrophysics Data System (ADS)
Skrutskie, Michael F.; Nelson, Matthew J.; Schmidt, Carl
2016-10-01
Fan Mountain Observatory, near Charlottesville, Virginia, is a dark-sky site that supports a number of telescopes including a 31-inch reflecting telescope equipped with a 1024x1024 HgCdTe 1-2.5 um (YJHK) imager. Reflected sunlight ordinarily overwhelms Io's comparatively weak K-band (2.0-2.4 um) volcanic emission in unresolved observations, however when Io is eclipsed in Jupiter's shadow even a small infrared-equipped telescope can detect Io's volcanic emission. The Fan Mountain Infrared Camera observed Io in eclipse at regular intervals, typically weekly, during the few months before and after Jupiter's March 2016 opposition. When in eclipse Io's Jupiter-facing hemisphere is oriented toward Earth with sub-Earth longitudes at the time of observation ranging from 345 - 360 degrees (pre-opposition) to 0 - 15 degrees (post-opposition). A K-band filter (2.04-2.42 um) provided a bulk measurement of Io's volcanic flux weighted largely toward the 2.4 um end of this filter given the typical 500K color temperature of the volcanic emission. Most epochs also included observation in a narrowband filter centered at 2.12 um that, when combined with the broadband "long" wavelength measurement, provided a proxy for color temperature. The K-band flux of Io varied by more than 2 magnitudes during the 7 month observation interval. The [2.12 um - K-band] color of the emission strongly correlated with the K-band flux in the expected sense that the color temperature of the emission increased when Io's broadband volcanic flux was the greatest. One epoch of TripleSpec near-IR Io eclipse spectroscopy (0.90 - 2.45 um; R~3000) from the Apache Point Observatory 3.5-meter telescope provided ground truth for transforming the filter photometry into quantitative temperatures.
Weather and Rotation on Young Brown Dwarfs
NASA Astrophysics Data System (ADS)
Vos, Johanna; Biller, Beth; Allers, Katelyn; Manjavacas, Elena; Liu, Michael; Best, William; Metchev, Stanimir; Buenzli, Esther; Bonavita, Mariangela; Eriksson, Simon; Dupuy, Trent; Kopytova, Taisiya; Brandner, Wolfgang; Henning, Thomas; Bonnefoy, Mickael; Crossfield, Ian; Schlieder, Joshua; Homeier, Derek; Janson, Markus; Radigan, Jacqueline
2018-05-01
As part of a large, ground-based survey for weather patterns on exoplanet analogues, we have detected J-band variability in 5 young exoplanet analogues. We have already carried out followup Spitzer monitoring of two objects and here we propose Spitzer 3.6um and 4.5um monitoring of three early-mid-L detections in our survey. The proposed observations will enable us to assess the role of gravity in the variability properties of these young objects by providing a full measure of mid-IR amplitude across the full L spectral sequence for low-gravity objects. The proposed observations will also allow us to measure the rotational periods of our three targets. This will provide vital information on the angular momentum of young brown dwarfs, while enabling us to correct for geometric effects when considering the variability properties of our targets. This study will act as a necessary pathfinder for future variability studies of free-floating and companion exoplanets with JWST.
2012-01-01
Microorganisms are ubiquitous on earth and have diverse metabolic transformative capabilities important for environmental biodegradation of chemicals that helps maintain ecosystem and human health. Microbial biodegradative metabolism is the main focus of the University of Minnesota Biocatalysis/Biodegradation Database (UM-BBD). UM-BBD data has also been used to develop a computational metabolic pathway prediction system that can be applied to chemicals for which biodegradation data is currently lacking. The UM-Pathway Prediction System (UM-PPS) relies on metabolic rules that are based on organic functional groups and predicts plausible biodegradative metabolism. The predictions are useful to environmental chemists that look for metabolic intermediates, for regulators looking for potential toxic products, for microbiologists seeking to understand microbial biodegradation, and others with a wide-range of interests. PMID:22587916
Urine Multi-drug Screening with GC-MS or LC-MS-MS Using SALLE-hybrid PPT/SPE.
Lee, Junhui; Park, Jiwon; Go, Ahra; Moon, Heesung; Kim, Sujin; Jung, Sohee; Jeong, Wonjoon; Chung, Heesun
2018-05-14
To intoxicated patients in the emergency room, toxicological analysis can be considerably helpful for identifying the involved toxicants. In order to develop a urine multi-drug screening (UmDS) method, gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS-MS) were used to determine targeted and unknown toxicants in urine. A GC-MS method in scan mode was validated for selectivity, limit of detection (LOD) and recovery. An LC-MS-MS multiple reaction monitoring (MRM) method was validated for lower LOD, recovery and matrix effect. The results of the screening analysis were compared with patient medical records to check the reliability of the screen. Urine samples collected from an emergency room were extracted through a combination of salting-out assisted liquid-liquid extraction (SALLE) and hybrid protein precipitation/solid phase extraction (hybrid PPT/SPE) plates and examined by GC-MS and LC-MS-MS. GC-MS analysis was performed as unknown drug screen and LC-MS-MS analysis was conducted as targeted drug screen. After analysis by GC-MS, a library search was conducted using an in-house library established with the automated mass spectral deconvolution and identification system (AMDISTM). LC-MS-MS used Cliquid®2.0 software for data processing and acquisition in MRM mode. An UmDS method by GC-MS and LC-MS-MS was developed by using a SALLE-hybrid PPT/SPE and in-house library. The results of UmDS by GC-MS and LC-MS-MS showed that toxicants could be identified from 185 emergency room patient samples containing unknown toxicants. Zolpidem, acetaminophen and citalopram were the most frequently encountered drugs in emergency room patients. The UmDS analysis developed in this study can be used effectively to detect toxic substances in a short time. Hence, it could be utilized in clinical and forensic toxicology practices.
CONTINUOUS MEASUREMENT OF PARTICLES (0.01-20.0 UM) IN AN OCCUPIED HOME, REED AND WALLACE, AAAR.
To better understand the contribution of outdoor and indoor sources to particle concentrations found in residential indoor air, an extensive monitoring effort has been undertaken in a three-story townhouse located in Reston, VA. Of particular interest was the determination of i...
VizieR Online Data Catalog: 14 unusual IR transients with Spitzer (SPRITEs) (Kasliwal+, 2017)
NASA Astrophysics Data System (ADS)
Kasliwal, M. M.; Bally, J.; Masci, F.; Cody, A. M.; Bond, H. E.; Jencson, J. E.; Tinyanont, S.; Cao, Yi; Contreras, C.; Dykhoff, D. A.; Amodeo, S.; Armus, L.; Boyer, M.; Cantiello, M.; Carlon, R. L.; Cass, A. C.; Cook, D.; Corgan, D. T.; Faella, J.; Fox, O. D.; Green, W.; Gehrz, R. D.; Helou, G.; Hsiao, E.; Johansson, J.; Khan, R. M.; Lau, R. M.; Langer, N.; Levesque, E.; Milne, P.; Mohamed, S.; Morrell, N.; Monson, A.; Moore, A.; Ofek, E. O.; O'Sullivan, D.; Parthasarathy, M.; Perez, A.; Perley, D. A.; Phillips, M.; Prince, T. A.; Shenoy, D.; Smith, N.; Surace, J.; van Dyk, S. D.; Whitelock, P. A.; Williams, R.
2017-11-01
The SPitzer InfraRed Intensive Transients Survey (SPIRITS) survey uses the IRAC instrument (FoV 5'x5') on board the warm Spitzer telescope to search for IR transients at 3.6um ([3.6]) and 4.5um ([4.5]). SPIRITS is a five-year survey from 2014 to 2018 (Kasliwal+ 2013sptz.prop10136K, 2016sptz.prop13053K). We are undertaking concomitant ground-based surveys to monitor the SPIRITS galaxy sample in the near-IR and the optical at roughly a monthly cadence. At the University of Minnesota's Mt. Lemmon Observing Facility (MLOF), we use the three-channel Two Micron All Sky Survey cameras mounted on the 1.52m IR telescope. At Las Campanas, we undertake near-IR monitoring with the Retrocam on Dupont 100 inch telescope and optical monitoring using the CCD on the Swope 40 inch telescope. At Palomar, we use the Samuel Oschin 48 inch (primarily gr-band) and Palomar 60 inch telescopes (gri-bands) for optical monitoring. Using the LCOGT network, we obtain additional optical monitoring in gri-bands. In addition, a follow-up of discovered transients was undertaken by a myriad of facilities including Keck, Magellan, Palomar 200 inch, SALT, and RATIR. Following non-detections from the ground, we were able to set even deeper magnitude limits for two transients based on a small HST Director's Discretionary program (GO/DD-13935, PI H. Bond). We imaged SPIRITS 14aje (in M101) and SPIRITS 14axa (in M81) with the Wide Field Camera 3 (WFC3) in 2014 September. (5 data files).
Fania, Claudio; Albertini, Federica; Palatini, Paolo
2017-08-01
The aim of this study was to determine the accuracy of the A&D UM-201 device coupled to several cuffs for different arm sizes for office blood pressure (BP) measurement according to the International Protocol of the European Society of Hypertension. Evaluation was carried out in 33 individuals. The mean age of the individuals was 59.3±13.2 years, systolic BP was 145.4±20.6 mmHg (range: 109-186 mmHg), diastolic BP was 87.3±18.0 mmHg (range: 50-124 mmHg), and arm circumference was 30.4±4.2 cm (range: 23-39 cm). The protocol requirements were followed precisely. The UM-201 monitor passed all requirements, fulfilling the standards of the protocol. On average, the device overestimated systolic BP by 3.0±2.1 mmHg and diastolic BP by 2.6±2.0 mmHg. These data show that the A&D UM-201 device coupled to several cuffs for different ranges of arm circumference fulfilled the requirements for validation by the International Protocol and can be recommended for clinical use in the adult population.
Development of a Biosensor Nanofluidic Platform for Integration with Terahertz Spectroscopic System
2014-06-27
space. The instrumentation for fabrication of micro/nano-fluidic chips including a Laser-Cutting System, a Sputtering system, a Spin Coating ...polyester (PET) substrate, as PET is more chemically and thermally resistant, and can be readily obtained in a variety of thicknesses down to 12.5 um...to create the array pattern on the silver coated PET substrate. Copper was then electrodeposited to a thickness of 5 um around the photoresist
User Modeling in Adaptive Hypermedia Educational Systems
ERIC Educational Resources Information Center
Martins, Antonio Constantino; Faria, Luiz; Vaz de Carvalho, Carlos; Carrapatoso, Eurico
2008-01-01
This document is a survey in the research area of User Modeling (UM) for the specific field of Adaptive Learning. The aims of this document are: To define what it is a User Model; To present existing and well known User Models; To analyze the existent standards related with UM; To compare existing systems. In the scientific area of User Modeling…
NASA Astrophysics Data System (ADS)
Huh, Keon; Oh, Darong; Son, Seok Young; Yoo, Hyung Jung; Song, Byeonghwa; Cho, Dong-il Dan; Seo, Jong-Mo; Kim, Sung Jae
2016-12-01
The concepts of microrobots has been drawn significant attentions recently since its unprecedented applicability in nanotechnology and biomedical field. Bacteria attached microparticles presented in this work are one of pioneering microrobot technology for self-propulsion or producing kinetic energy from ambient for their motions. Microfluidic device, especially utilizing laminar flow characteristics, were employed for anisotropic attachment of Salmonella typhimurium flagellated chemotactic bacteria to 30 um × 30 um and 50 um × 50 um microparticles that made of biodegradable polymer. Any toxic chemicals or harmful treatments were excluded during the attachment process and it finished within 100 s for the anisotropic attachment. The attachments were directly confirmed by fluorescent intensity changes and SEM visualization. Chemotaxis motions were tracked using aspartate and the maximum velocity of the bacteria-attached microrobot was measured to be 5 um/s which is comparable to prior state of art technologies. This reusable and scalable method could play a key role in chemotaxis delivery of functional microparticles such as drug delivery system.
NASA Astrophysics Data System (ADS)
Johnson, Marcus; Jung, Youngsun; Dawson, Daniel; Supinie, Timothy; Xue, Ming; Park, Jongsook; Lee, Yong-Hee
2018-07-01
The UK Met Office Unified Model (UM) is employed by many weather forecasting agencies around the globe. This model is designed to run across spatial and time scales and known to produce skillful predictions for large-scale weather systems. However, the model has only recently begun running operationally at horizontal grid spacings of ˜1.5 km [e.g., at the UK Met Office and the Korea Meteorological Administration (KMA)]. As its microphysics scheme was originally designed and tuned for large-scale precipitation systems, we investigate the performance of UM microphysics to determine potential inherent biases or weaknesses. Two rainfall cases from the KMA forecasting system are considered in this study: a Changma (quasi-stationary) front, and Typhoon Sanba (2012). The UM output is compared to polarimetric radar observations in terms of simulated polarimetric radar variables. Results show that the UM generally underpredicts median reflectivity in stratiform rain, producing high reflectivity cores and precipitation gaps between them. This is partially due to the diagnostic rain intercept parameter formulation used in the one-moment microphysics scheme. Model drop size is generally both underand overpredicted compared to observations. UM frozen hydrometeors favor generic ice (crystals and snow) rather than graupel, which is reasonable for Changma and typhoon cases. The model performed best with the typhoon case in terms of simulated precipitation coverage.
Petersen Multipliers for Several SEU (Single Event Upset) Environment Models.
1986-09-30
The Aerospace Corporation El Segundo, CA 90245 30 Scptcmbcr 1986 Prepared for SPACE DIVISION AIR FORCE SYSTEMS COMMAND 0Los Angeles Air Force Station...X (pC/om)2 /Um " (for S in Pm2 and for in picocoulombs per um). (In another system of units, the constant in the equation for F, above, takes the...distributions that may be expected under a wide variety of conditions. These models have since become standards for use in the specification of system
Modeling Suomi-NPP VIIRS Solar Diffuser Degradation due to Space Radiation
NASA Astrophysics Data System (ADS)
Shao, X.; Cao, C.
2014-12-01
The Visible Infrared Imaging Radiometer Suite (VIIRS) onboard Suomi-NPP uses a solar diffuser (SD) as on-board radiometric calibrator for the reflective solar band (RSB) calibration. Solar diffuser is made of Spectralon (one type of fluoropolymer) and was chosen because of its controlled reflectance in the VIS-NIR-SWIR region and its near-Lambertian reflectance profile. Spectralon is known to degrade in reflectance at the blue end of the spectrum due to exposure to space radiations such as solar UV radiation and energetic protons. These space radiations can modify the Spectralon surface through breaking C-C and C-F bonds and scissioning or cross linking the polymer, which causes the surface roughness and degrades its reflectance. VIIRS uses a SDSM (Solar Diffuser Stability Monitor) to monitor the change in the Solar Diffuser reflectance in the 0.4 - 0.94 um wavelength range and provide a correction to the calibration constants. The H factor derived from SDSM reveals that reflectance of 0.4 to 0.6um channels of VIIRS degrades faster than the reflectance of longer wavelength RSB channels. A model is developed to derive characteristic parameters such as mean SD surface roughness height and autocovariance length of SD surface roughness from the long term spectral degradation of SD reflectance as monitored by SDSM. These two parameters are trended to assess development of surface roughness of the SD over the operation period of VIIRS.
DIRECT-DEPOSITION INFRARED SPECTROMETRY WITH GAS AND SUPERCRITICAL FLUID CHROMATOGRAPHY
A direct-deposition Fourier transform infrared (FT-IR) system has been evaluated for applicability to gas chromatography (GC) and supercritical fluid chromatography (SFC) of environmental analytes. A 100-um i.d. fused-silica transfer line was used for GC, and a 50-um transfer lin...
A Large-Telescope Natural Guide Star AO System
NASA Technical Reports Server (NTRS)
Redding, David; Milman, Mark; Needels, Laura
1994-01-01
None given. From overview and conclusion:Keck Telescope case study. Objectives-low cost, good sky coverage. Approach--natural guide star at 0.8um, correcting at 2.2um.Concl- Good performance is possible for Keck with natural guide star AO system (SR>0.2 to mag 17+).AO-optimized CCD should b every effective. Optimizing td is very effective.Spatial Coadding is not effective except perhaps at extreme low light levels.
A Systems Engineering Analysis of Unmanned Maritime Systems for U.S. Coast Guard Missions
2013-06-01
accidental, are apparent when considering the Fukushima Daiichi nuclear disaster and its follow -on radiation hazards [52]. In addition, recent increases in...on the maritime domain increases innovative approaches such as UMS will be vital in gaining awareness , especially in remote locations such as the...Horizon oil disaster clean-up employed a limited use of UMS, specifically Remotely Op- erated Vehicles [20]. As oil drilling increases throughout the
Transboundary influences of paniculate matter less than or equal to 2.5 um in aerodynamic diameter (PM2.5,) have been investigated in a U.S.-Mexican border region using a dual fine particle sequential sampler (DFPSS) and tapered element oscillating microbalance (TEOM). Daily me...
Towards reducing the impacts of unwanted movements on identification of motion intentions.
Li, Xiangxin; Chen, Shixiong; Zhang, Haoshi; Samuel, Oluwarotimi Williams; Wang, Hui; Fang, Peng; Zhang, Xiufeng; Li, Guanglin
2016-06-01
Surface electromyogram (sEMG) has been extensively used as a control signal in prosthesis devices. However, it is still a great challenge to make multifunctional myoelectric prostheses clinically available due to a number of critical issues associated with existing EMG based control strategy. One such issue would be the effect of unwanted movements (UMs) that are inadvertently done by users on the performance of movement classification in EMG pattern recognition based algorithms. Since UMs are not considered in training a classifier, they would decay the performance of a trained classifier in identifying the target movements (TMs), which would cause some undesired actions in control of multifunctional prostheses. In this study, the impact of UMs was systemically investigated in both able-bodied subjects and transradial amputees. Our results showed that the UMs would be unevenly classified into all classes of the TMs. To reduce the impact of the UMs on the performance of a classifier, a new training strategy that would categorize all possible UMs into a new movement class was proposed and a metric called Reject Ratio that is a measure of how many UMs is rejected by a trained classifier was adopted. The results showed that the average Reject Ratio across all the participants was greater than 91%, meanwhile the average classification accuracy of TMs was above 99% when UMs occurred. This suggests that the proposed training strategy could greatly reduce the impact of UMs on the performance of the trained classifier in identifying the TMs and may enhance the robustness of myoelectric control in clinical applications. Copyright © 2016 Elsevier Ltd. All rights reserved.
Novel ophthalmological OCT instrument design
NASA Astrophysics Data System (ADS)
Xu, Xiaonan; Gao, Jiansong; Guo, Jihua; Xue, Ping
2002-04-01
This paper presents a novel ophthamological optical coherence tomography detecting instrument, which we design, and introduces measuring arm emphatically. For glaucoma which is very common in the Orient, this system can achieve both the eyeground detection and the canthus detection. And it combines the cranny lamp's conventional detection with optical coherence tomography. Considering all the system, this design has a longitudinal resolution of 15 um, and a transverse resolution of 20 um at imaging velocity of 4 frames per second.
Students' Perceptions of Blackboard and Moodle in a Portuguese University
ERIC Educational Resources Information Center
Carvalho, Ana; Areal, Nelson; Silva, Joaquim
2011-01-01
The use of learning management systems (LMS) has grown considerably in universities around the world. The University of Minho (UM) has pioneered in this area in Portugal, adopting Blackboard as its official LMS. Moodle is also used in UM in scattered initiatives, allowing for interesting comparisons. Previous studies comparing Blackboard and…
III-V strain layer superlattice based band engineered avalanche photodiodes (Presentation Recording)
NASA Astrophysics Data System (ADS)
Ghosh, Sid
2015-08-01
Laser detection and ranging (LADAR)-based systems operating in the Near Infrared (NIR) and Short Wave Infrared (SWIR) have become popular optical sensors for remote sensing, medical, and environmental applications. Sophisticated laser-based radar and weapon systems used for long-range military and astronomical applications need to detect, recognize, and track a variety of targets under a wide spectrum of atmospheric conditions. Infrared APDs play an important role in LADAR systems by integrating the detection and gain stages in a single device. Robust silicon-APDs are limited to visible and very near infrared region (< 1 um), while InGaAs works well up to wavelengths of about 1.5um. Si APDs have low multiplication or excess noise but are limited to below 1um due very poor quantum efficiency above 0.8um. InGaAs and Ge APDs operate up to wavelengths of 1.5um but have poor multiplication or excess noise due to a low impact ionization coefficient ratio between electrons and holes. For the past several decades HgCdTe has been traditionally used in longer wavelength (> 3um) infrared photon detection applications. Recently, various research groups (including Ghosh et. al.) have reported SWIR and MWIR HgCdTe APDs on CdZnTe and Si substrates. However, HgCdTe APDs suffer from low breakdown fields due to material defects, and excess noise increases significantly at high electric fields. During the past decade, InAs/GaSb Strain Layer Superlattice (SLS) material system has emerged as a potential material for the entire infrared spectrum because of relatively easier growth, comparable absorption coefficients, lower tunneling currents and longer Auger lifetimes resulting in enhanced detectivities (D*). Band engineering in type II SLS allows us to engineer avalanche properties of electrons and holes. This is a great advantage over bulk InGaAs and HgCdTe APDs where engineering avalanche properties is not possible. The talk will discuss the evolution of superlattice based avalanche photodiodes and some of the recent results on the work being done at Raytheon on SWIR avalanche photodiodes.
Bolte, Gabriele; David, Madlen; Dębiak, Małgorzata; Fiedel, Lotta; Hornberg, Claudia; Kolossa-Gehring, Marike; Kraus, Ute; Lätzsch, Rebecca; Paeck, Tatjana; Palm, Kerstin; Schneider, Alexandra
2018-06-01
The comprehensive consideration of sex/gender in health research is essential to increase relevance and validity of research results. Contrary to other areas of health research, there is no systematic summary of the current state of research on the significance of sex/gender in environmental health. Within the interdisciplinary research network Sex/Gender-Environment-Health (GeUmGe-NET) the current state of integration of sex/gender aspects or, respectively, gender theoretical concepts into research was systematically assessed within selected topics of the research areas environmental toxicology, environmental medicine, environmental epidemiology and public health research on environment and health. Knowledge gaps and research needs were identified in all research areas. Furthermore, the potential for methodological advancements by using gender theoretical concepts was depicted. A dialogue between biomedical research, public health research, and gender studies was started with the research network GeUmGe-NET. This dialogue has to be continued particularly regarding a common testing of methodological innovations in data collection and data analysis. Insights of this interdisciplinary research are relevant for practice areas such as environmental health protection, health promotion, environmental justice, and environmental health monitoring.
NASA Astrophysics Data System (ADS)
Prieto, Sandra P.; Greening, Gage J.; Lai, Keith K.; Muldoon, Timothy J.
2016-03-01
Two-photon excitation of label-free tissue is of increasing interest, as advances have been made in endoscopic clinical application of multiphoton microscopy, such as second harmonic generation (SHG) scanning endoscopy used to monitor cervical collagen in mice1. We used C57BL mice as a model to investigate the progression of gastrointestinal structures, specifically glandular area and circularity. We used multiphoton microscopy to image ex-vivo label-free murine colon, focusing on the collagen structure changes over time, in mice ranging from 10 to 20 weeks of age. Series of images were acquired within the colonic and intestinal tissue at depth intervals of 20 microns from muscularis to the epithelium, up to a maximum depth of 180 microns. The imaging system comprised a two-photon laser tuned to 800nm wavelength excitation, and the SHG emission was filtered with a 400/40 bandpass filter before reaching the photomultiplier tube. Images were acquired at 15 frames per second, for 200 to 300 cumulative frames, with a field of view of 261um by 261um, and 40mW at sample. Image series were compared to histopathology H&E slides taken from adjacent locations. Quantitative metrics for determining differences between murine glandular structures were applied, specifically glandular area and circularity.
LIDAR technology for measuring trace gases on Mars and Earth
NASA Astrophysics Data System (ADS)
Riris, H.; Abshire, J. B.; Graham, Allan; Hasselbrack, William; Rodriguez, Mike; Sun, Xiaoli; Weaver, Clark; Mao, Jianping; Kawa, Randy; Li, Steve; Numata, Kenji; Wu, Stewart
2017-11-01
Trace gases and their isotopic ratios in planetary atmospheres offer important but subtle clues as to the origins of a planet's atmosphere, hydrology, geology, and potential for biology. An orbiting laser remote sensing instrument is capable of measuring trace gases on a global scale with unprecedented accuracy, and higher spatial resolution that can be obtained by passive instruments. For Earth we have developed laser technique for the remote measurement of the tropospheric CO2, O2, and CH4 concentrations from space. Our goal is to develop a space instrument and mission approach for active CO2 measurements. Our technique uses several on and off-line wavelengths tuned to the CO2 and O2 absorption lines. This exploits the atmospheric pressure broadening of the gas lines to weigh the measurement sensitivity to the atmospheric column below 5 km and maximizes sensitivity to CO2 changes in the boundary layer where variations caused by surface sources and sinks are largest. Simultaneous measurements of O2 column use a selected region in the Oxygen A-band. Laser altimetry and atmospheric backscatter can also be measured simultaneously, which permits determining the surface height and measurements made to thick cloud tops and through aerosol layers. We use the same technique but with a different transmitter at 1.65 um to measure methane concentrations. Methane is also a very important trace gas on earth, and a stronger greenhouse gas than CO2 on a per molecule basis. Accurate, global observations are needed in order to better understand climate change and reduce the uncertainty in the carbon budget. Although carbon dioxide is currently the primary greenhouse gas of interest, methane can have a much larger impact on climate change. Methane levels have remained relatively constant over the last decade but recent observations in the Arctic have indicated that levels may be on the rise due to permafrost thawing. NASA's Decadal Survey underscored the importance of Methane as a greenhouse gas and called for a mission to measure CO2, CO and CH4. Methane has absorptions in the mid-infrared (3.3 um) and the near infrared (1.65 um). The 3.3 um spectral region is ideal for planetary (Mars) Methane monitoring, but unfortunately is not suitable for earth monitoring since the Methane absorption lines are severely interfered with by water. The near infra-red overtones of Methane at 1.65 um are relatively free of interference from other atmospheric species and are suitable for Earth observations. The methane instrument uses Optical Parametric Generation (OPG) along with sensitive detectors to achieve the necessary sensitivity. Our instrument generates and detects tunable laser signals in the 3.3 or 1.65 um spectral regions with different detectors in order to measure methane on Earth or Mars. For Mars, the main interest in methane is its importance as a biogenic marker.
Desenvolvimento das câmeras de raios-X duros do satélite MIRAX
NASA Astrophysics Data System (ADS)
Braga, J.; Rothschild, R.; Staubert, R.; Heise, J.; Remillard, R.; D'Amico, F.; Jablonski, F.; Mejía, J.; Carvalho, H.; Heindl, B.; Matteson, J.; Kendziorra, E.; Wilms, J.; in't Zand, J.; Kuulkers, E.
2003-08-01
O MIRAX (Monitor e Imageador de RAios-X) é um projeto de desenvolvimento de um pequeno satélite astronômico de raios-X (~200 kg, ~240 W). A estratégia básica da missão será observar continuamente (~9 meses por ano) a região central (~1000 graus2) do plano Galáctico e realizar estudos espectroscópicos de banda larga (2-200 keV) e alta sensibilidade de um grande conjunto de fontes através de imagens com resolução de ~6'. Isso proporcionará uma cobertura inédita do "espaço de descobertas" através da detecção, localização, identificação e estudo detalhado de fenômenos imprevisíveis, tais como transientes fracos de raios-X, novas rápidas de raios-X e bursts de raios gama, assim como o estudo de fontes com emissão persistente. Neste trabalho apresentamos o projeto das duas câmeras de raios-X duros (CXDs) do MIRAX, que irão operar na faixa de 10 a 200 keV. Cada CXD consistirá de um plano de detectores CZT (Cd0,9Zn0,1Te) de 0,5 mm de resolução espacial e 370 cm2 de área total, e de uma máscara codificada com elementos quadrados de 1,3 mm de lado e 0,5 cm de espessura. A máscara terá dimensões de 315 cm ´ 275 cm e será montada a 700 cm de distância dos detectores. Com essa configuração as CXDs terão 6' de resolução angular e, quando colocadas a um ângulo de 29° entre si, as duas câmeras propiciam um campo totalmente codificado de 39° ´ 6°12' e um campo total de 76° ´ 44°. Serão apresentadas simulações de observações da região do plano Galáctico com o conjunto formado pelas duas CXDs.
Observations of the new gravitational lens system UM 673 = Q 0142-100
NASA Astrophysics Data System (ADS)
Surdej, J.; Magain, P.; Swings, J.-P.; Borgeest, U.; Courvoisier, T. J.-L.; Kayer, R.; Kellermann, K. I.; Kuhr, H.; Refsdal, S.
1988-06-01
The authors have recently initiated a high resolution direct imaging survey of a selected sample of highly luminous quasars (HLQs). The observations are carried out with the 2.2 m telescope at ESO, and with the VLA at the NRAO, New Mexico. Following the first observing run at ESO, the authors have reported the discovery of a new gravitational lens system for the HLQ UM 673 = Q 0142-100. Additional observations supporting this interpretation are discussed here. Application of gravitational optometry to this system is given: a value of M0 = 2.4×1011M_sun; is derived for the mass of the lensing galaxy located between UM 673 A and B and a most likely estimate of Δt = 7 weeks is found for the expected delay between the arrival times of a similar variability event in the two lensed images of the quasar (H0 = 75 km s-1Mpc-1, q0 = 0).
Thermodynamics of Anharmonic Systems: Uncoupled Mode Approximations for Molecules
Li, Yi-Pei; Bell, Alexis T.; Head-Gordon, Martin
2016-05-26
The partition functions, heat capacities, entropies, and enthalpies of selected molecules were calculated using uncoupled mode (UM) approximations, where the full-dimensional potential energy surface for internal motions was modeled as a sum of independent one-dimensional potentials for each mode. The computational cost of such approaches scales the same with molecular size as standard harmonic oscillator vibrational analysis using harmonic frequencies (HO hf). To compute thermodynamic properties, a computational protocol for obtaining the energy levels of each mode was established. The accuracy of the UM approximation depends strongly on how the one-dimensional potentials of each modes are defined. If the potentialsmore » are determined by the energy as a function of displacement along each normal mode (UM-N), the accuracies of the calculated thermodynamic properties are not significantly improved versus the HO hf model. Significant improvements can be achieved by constructing potentials for internal rotations and vibrations using the energy surfaces along the torsional coordinates and the remaining vibrational normal modes, respectively (UM-VT). For hydrogen peroxide and its isotopologs at 300 K, UM-VT captures more than 70% of the partition functions on average. By con trast, the HO hf model and UM-N can capture no more than 50%. For a selected test set of C2 to C8 linear and branched alkanes and species with different moieties, the enthalpies calculated using the HO hf model, UM-N, and UM-VT are all quite accurate comparing with reference values though the RMS errors of the HO model and UM-N are slightly higher than UM-VT. However, the accuracies in entropy calculations differ significantly between these three models. For the same test set, the RMS error of the standard entropies calculated by UM-VT is 2.18 cal mol -1 K -1 at 1000 K. By contrast, the RMS error obtained using the HO model and UM-N are 6.42 and 5.73 cal mol -1 K -1, respectively. For a test set composed of nine alkanes ranging from C5 to C8, the heat capacities calculated with the UM-VT model agree with the experimental values to within a RMS error of 0.78 cal mol -1 K -1 , which is less than one-third of the RMS error of the HO hf (2.69 cal mol -1 K -1) and UM-N (2.41 cal mol -1 K -1) models.« less
Correction of large amplitude wavefront aberrations
NASA Astrophysics Data System (ADS)
Cornelissen, S. A.; Bierden, P. A.; Bifano, T. G.; Webb, R. H.; Burns, S.; Pappas, S.
2005-12-01
Recently, a number of research groups around the world have developed ophthalmic instruments capable of in vivo diffraction limited imaging of the human retina. Adaptive optics was used in these systems to compensate for the optical aberrations of the eye and provide high contrast, high resolution images. Such compensation uses a wavefront sensor and a wavefront corrector (usually a deformable mirror) coordinated in a closed- loop control system that continuously works to counteract aberrations. While those experiments produced promising results, the deformable mirrors have had insufficient range of motion to permit full correction of the large amplitude aberrations of the eye expected in a normal population of human subjects. Other retinal imaging systems developed to date with MEMS (micro-electromechanical systems) DMs suffer similar limitations. This paper describes the design, manufacture and testing of a 6um stroke polysilicon surface micromachined deformable mirror that, coupled with an new optical method to double the effective stroke of the MEMS-DM, will permit diffraction-limited retinal imaging through dilated pupils in at least 90% of the human population. A novel optical design using spherical mirrors provides a double pass of the wavefront over the deformable mirror such that a 6um mirror displacement results in 12um of wavefront compensation which could correct for 24um of wavefront error. Details of this design are discussed. Testing of the effective wavefront modification was performed using a commercial wavefront sensor. Results are presented demonstrating improvement in the amplitude of wavefront control using an existing high degree of freedom MEMS deformable mirror.
Portable microscopy platform for the clinical and environmental monitoring
NASA Astrophysics Data System (ADS)
Wang, Weiming; Yu, Yan; Huang, Hui; Ou, Jinping
2016-04-01
Light microscopy can not only address various diagnosis needs such as aquatic parasites and bacteria such as E. coli in water, but also provide a method for the screening of red tide. Traditional microscope based on the smartphone created by adding lens couldn't keep the tradeoff between field-of-view(FOV) and the resolution. In this paper, we demonstrate a non-contact, light and cost-effective microscope platform, that can image highly dense samples with a spatial resolution of ~0.8um over a field-of-view(FOV) of >1mm2. After captured the direct images, we performed the pixel super-resolution algorithm to improve the image resolution and overcome the hardware interference. The system would be a good point-of-care diagnostic solution in resource limited settings. We validated the performance of the system by imaging resolution test targets, the squamous cell cancer(SqCC) and green algae that necessary to detect the squamous carcinoma and red tide
Erfassung tribologischer Zusammenhänge und Erkenntnisse in einer Datenbank
NASA Astrophysics Data System (ADS)
Gold, Peter Werner; Jacobs, Georg; Loos, J.; Rombach, Volker; Kurutas, Savas; Fröde, Astrid
Die Datenbank enthält die tribologischen und stofflichen Daten, die innerhalb des Sonderforschungsbereichs 442 ermittelt wurden. Sie wird genutzt, um Informationen über die Eigenschaften von Schmierstoffen und Werkstoffverbunden, sowie über Prüfstände und Versuchsergebnisse zu erhalten. Diese Wissensbasis kann dazu beitragen, ökologisch verträgliche Tribosysteme mit Hilfe der Auswerte-Systeme (Module) auszulegen. Dabei handelt es sich um Berechnungswerkzeuge und Expertenwissen z. B. in Bezug auf die Auswahl von Schichtsystemen. Eine nähere Beschreibung der Auswerte-Systeme kann den folgenden Abschnitten entnommen werden.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giessen, B.C.; Elliott, R.O.
1978-01-01
The results of a preparative and calorimetric study forming part of a continuing investigation of the new actinide glasses are reported. Specifically, lower bounds for the composition limits of glass formation (G.F.) at moderate cooling rates have been obtained for the U-M (M = Mn, Fe, Co, Ni) systems and the thermal stabilities of glasses in these four systems as well as for a U-V glass and a U-Cr glass have been surveyed.
Thermal Analysis of the European XFEL Intersection Control Rack
NASA Astrophysics Data System (ADS)
Concha, P.; Vazquez, C.
2014-04-01
The three undulator segments of the European X-ray Free Electron Laser contain a total of 88 intersections cells. Each intersection accommodates a quadrupole magnet on top of a high precision X-Y positioning table, a beam position monitor, four air coil correctors and a phase shifter. The Intersection Control Rack is an electrical cabinet containing the necessary electronics to control both the quadrupole and the phase shifter movements (which are stepper motor based) with a repeatability of less than 1 um and 10 um, respectively. Four different cabinets have been extensively tested to ensure that they meet specifications. These tests include a thermal analysis to study position measurements dependence on the temperature. This paper introduces a description of the thermal issue, analyses the causes and consequences of heating, presents the results of the different tests performed, and concludes the best design and operating conditions to achieve a good performance.
Comparison of heavy metal toxicity in continuous flow and batch reactors
NASA Astrophysics Data System (ADS)
Sengor, S. S.; Gikas, P.; Moberly, J. G.; Peyton, B. M.; Ginn, T. R.
2009-12-01
The presence of heavy metals may significantly affect microbial growth. In many cases, small amounts of particular heavy metals may stimulate microbial growth; however, larger quantities may result in microbial growth reduction. Environmental parameters, such as growth pattern may alter the critical heavy metal concentration, above which microbial growth stimulation turns to growth inhibition. Thus, it is important to quantify the effects of heavy metals on microbial activity for understanding natural or manmade biological reactors, either in situ or ex situ. Here we compare the toxicity of Zn and Cu on Arthrobacter sp., a heavy metal tolerant microorganism, under continuous flow versus batch reactor operations. Batch and continuous growth tests of Arthrobacter sp. were carried out at various individual and combined concentrations of Zn and Cu. Biomass concentration (OD) was measured for both the batch and continuous reactors, whereas ATP, oxygen uptake rates and substrate concentrations were additionally measured for the continuous system. Results indicated that Cu was more toxic than Zn under all conditions for both systems. In batch reactors, all tested Zn concentrations up to 150 uM showed a stimulatory effect on microbial growth. However, in the case of mixed Zn and Cu exposures, the presence of Zn either eliminated (at the 50 uM level both Zn and Cu) or reduced by ~25% (at the 100 and 150 uM levels both Zn and Cu) the Cu-induced inhibition. In the continuous system, only one test involved combined Cu (40uM) and Zn (125uM) and this test showed similar results to the 40uM Cu continuous test, i.e., no reduction in inhibition. The specific ATP concentration, i.e., ATP/OD, results for the continuous reactor showed an apparent recovery for both Cu-treated populations, although neither the OD nor glucose data showed any recovery. This may reflect that the individual microorganisms that survived after the addition of heavy metals, kept maintaining the usual ATP levels, as before metal addition. The last may imply a short of adaptation by some microorganisms to the presence of heavy metals. Overall, the batch reactor tests underestimated significantly the heavy metal inhibition, as compared to the continuous flow reactors. Therefore, the results of batch reactor tests should be used with some caution when heavy metal inhibition is to be interpreted for continuous flow natural environmental systems, such as rivers or wetlands.
NASA Astrophysics Data System (ADS)
Kim, Daeik D.; Thomas, Mikkel A.; Brooke, Martin A.; Jokerst, Nan M.
2004-06-01
Arrays of embedded bipolar junction transistor (BJT) photo detectors (PD) and a parallel mixed-signal processing system were fabricated as a silicon complementary metal oxide semiconductor (Si-CMOS) circuit for the integration optical sensors on the surface of the chip. The circuit was fabricated with AMI 1.5um n-well CMOS process and the embedded PNP BJT PD has a pixel size of 8um by 8um. BJT PD was chosen to take advantage of its higher gain amplification of photo current than that of PiN type detectors since the target application is a low-speed and high-sensitivity sensor. The photo current generated by BJT PD is manipulated by mixed-signal processing system, which consists of parallel first order low-pass delta-sigma oversampling analog-to-digital converters (ADC). There are 8 parallel ADCs on the chip and a group of 8 BJT PDs are selected with CMOS switches. An array of PD is composed of three or six groups of PDs depending on the number of rows.
Representing metabolic pathway information: an object-oriented approach.
Ellis, L B; Speedie, S M; McLeish, R
1998-01-01
The University of Minnesota Biocatalysis/Biodegradation Database (UM-BBD) is a website providing information and dynamic links for microbial metabolic pathways, enzyme reactions, and their substrates and products. The Compound, Organism, Reaction and Enzyme (CORE) object-oriented database management system was developed to contain and serve this information. CORE was developed using Java, an object-oriented programming language, and PSE persistent object classes from Object Design, Inc. CORE dynamically generates descriptive web pages for reactions, compounds and enzymes, and reconstructs ad hoc pathway maps starting from any UM-BBD reaction. CORE code is available from the authors upon request. CORE is accessible through the UM-BBD at: http://www. labmed.umn.edu/umbbd/index.html.
VizieR Online Data Catalog: 70um-1.2mm and N2H+ maps of IRDC18454 (W43) (Beuther+,
NASA Astrophysics Data System (ADS)
Beuther, H.; Tackenberg, J.; Linz, H.; Henning, T.; Krause, O.; Ragan, S.; Nielbock, M.; Launhardt, R.; Schmiedeke, A.; Schuller, F.; Carlhoff, P.; Nguyen-Luong, Q.; Sakai, T.
2011-11-01
The cloud complex with a size of ~6'x6' was observed with PACS on Herschel on 2010 March 9. Maps at 250, 350, and 500um were obtained with SPIRE 2010) on 2010 March 11. We observed IRDC18454-1 with the Plateau de Bure Interferometer during five nights in October and November 2009 at 93GHz in the C and D configurations. The N2H+ data has been observed using the BEARS receiver at the NRO 45m telescope in Nobeyama, Japan. The different velocity components have been observed one in April 2010 with an average system temperature of Tsys=206K, the second in June, at slightly lower Tsys. The MIPS 24um data (from MIPSGAL) as well as the IRAC 8um observations (from GLIMPSE) are taken from the Spitzer archive. The 1.2mm continuum data were first presented in Beuther et al. (2002, Cat. J/ApJ/566/945) and the APEX 870um data are part of the ATLASGAL survey of the Galactic plane (Schuller et al., 2009A&A...504..415S). (2 data files).
A Portable Farmland Information Collection System with Multiple Sensors.
Zhang, Jianfeng; Hu, Jinyang; Huang, Lvwen; Zhang, Zhiyong; Ma, Yimian
2016-10-22
Precision agriculture is the trend of modern agriculture, and it is also one of the important ways to realize the sustainable development of agriculture. In order to meet the production requirements of precision agriculture-efficient use of agricultural resources, and improving the crop yields and quality-some necessary field information in crop growth environment needs to be collected and monitored. In this paper, a farmland information collection system is developed, which includes a portable farmland information collection device based on STM32 (a 32-bit comprehensive range of microcontrollers based on ARM Crotex-M3), a remote server and a mobile phone APP. The device realizes the function of portable and mobile collecting of multiple parameters farmland information, such as chlorophyll content of crop leaves, air temperature, air humidity, and light intensity. UM220-III (Unicore Communication Inc., Beijing, China) is used to realize the positioning based on BDS/GPS (BeiDou Navigation Satellite System, BDS/Global Positioning System, GPS) dual-mode navigation and positioning system, and the CDMA (Code Division Multiple Access, CDMA) wireless communication module is adopted to realize the real-time remote transmission. The portable multi-function farmland information collection system is real-time, accurate, and easy to use to collect farmland information and multiple information parameters of crops.
A Portable Farmland Information Collection System with Multiple Sensors
Zhang, Jianfeng; Hu, Jinyang; Huang, Lvwen; Zhang, Zhiyong; Ma, Yimian
2016-01-01
Precision agriculture is the trend of modern agriculture, and it is also one of the important ways to realize the sustainable development of agriculture. In order to meet the production requirements of precision agriculture—efficient use of agricultural resources, and improving the crop yields and quality—some necessary field information in crop growth environment needs to be collected and monitored. In this paper, a farmland information collection system is developed, which includes a portable farmland information collection device based on STM32 (a 32-bit comprehensive range of microcontrollers based on ARM Crotex-M3), a remote server and a mobile phone APP. The device realizes the function of portable and mobile collecting of multiple parameters farmland information, such as chlorophyll content of crop leaves, air temperature, air humidity, and light intensity. UM220-III (Unicore Communication Inc., Beijing, China) is used to realize the positioning based on BDS/GPS (BeiDou Navigation Satellite System, BDS/Global Positioning System, GPS) dual-mode navigation and positioning system, and the CDMA (Code Division Multiple Access, CDMA) wireless communication module is adopted to realize the real-time remote transmission. The portable multi-function farmland information collection system is real-time, accurate, and easy to use to collect farmland information and multiple information parameters of crops. PMID:27782076
Slips, lapses and mistakes inthe use of equipment by nurses in an intensive care unit.
Ribeiro, Gabriella da Silva Rangel; Silva, Rafael Celestino da; Ferreira, Márcia de Assunção; Silva, Grazielle Rezende da
2016-01-01
Toidentify the occurrence of errors in the use of equipment by nurses working in intensive careandanalyzing them in the framework of James Reason's theory of human error. Qualitative field study in the intensive care unit of a federal hospital in the city of Rio de Janeiro. Observation and interviews were conductedwith eight nurses, from March to December 2014. Content analysis was used for the interviews, as well as the description of the scenes observed. Lapses of memory and attention were identified in the handling of infusion pumps, as well as planning failures during the programming of monitors. Errors cause adverse events that compromise patient safety. The authors propose creation of an instrument for daily checking of equipment, with checks throughout the work process in the programming of infusion pumps and monitors, in order to reduce failures and memory lapses. Identificar a ocorrência de erros na utilização de equipamentos por enfermeiros que atuam na terapia intensiva, analisando-os à luz da teoria do erro humano de James Reason. Pesquisa de campo, qualitativa, na Unidade de Terapia Intensiva de um hospital federal do Rio de Janeiro. Realizou-se observação e entrevista com oito enfermeiros, de março a dezembro de 2014. Aplicou-se análise de conteúdo nas entrevistas e descrição densa nas cenas observadas. Identificaram-se falhas de memória e de atenção no manuseio das bombas infusoras e falhas de planejamento durante a programação dos monitores. Os erros causam eventos adversos que comprometem a segurança do paciente. Propõe-se um instrumento de verificação diária dos equipamentos, com checagens ao longo do processo de trabalho da programação das bombas infusoras e monitores, no intuito de reduzir as falhas e esquecimentos.
Description of the REMS Ground Temperature Sensor aboard MSL NASA mission to Mars
NASA Astrophysics Data System (ADS)
Armiens, C.; Sebastian, E.; Gomez-Elvira, J.
2009-04-01
The Rover Environmental Monitoring Station, REMS, is part of the payload of the Mars Science Laboratory, MSL, a NASA mission to the red planet recently scheduled to launch on the fall of 2011. REMS comprises several instruments aimed at measuring ground and air temperature, wind speed and direction, ultraviolet radiation, pressure and humidity. The Ground Temperature Sensor, GTS, is a contactless multi band pyrometer. It is composed of three thermopiles measuring in different bands: 8 - 14 um, 16 - 20 um and 14.5 - 15.5 um. The first two bands are optimized for the higher and lower temperatures expected to be present on Mars during the lifetime of the mission. They also avoid the radiation generated by the rover itself, the Radioisotope Thermoelectric Generator, RTG, and the Sun that is reflected on the ground and reaches the thermopiles, as well as the atmospheric emission originated by the CO2. The use of two different bands to measure ground temperature allows the estimation of the emissivity of the surface by means of colour pyrometry algorithms. Thus we may determine not only the brightness temperature but also the real temperature of the ground, i.e., the kinetic temperature. The estimation of the emissivity may serve also to detect changes in the composition of the ground, as, for example, the formation of frost. The third thermopile is centred in the CO2 absorption band, the main component of the Martian atmosphere. This allows the determination of the residual influence that the atmosphere may have in the other two thermopile's bands. The brightness temperature of the air may also be estimated from this third thermopile. During Martian operations, the system may be degraded due to the deposition of dust over the thermopiles' filter. In order to correct for this degradation, the system includes a calibration plate, which partially fills the field of view of the thermopiles. This plate may be heated several degrees. Analyzing the signals before and during the heating process, one may estimate the fraction of the filter covered by dust. This procedure needs the ground temperature to be as stable as possible, so it will be performed just before dawn, when soil temperature changes are expected to be minimum.
Origins Space Telescope: The Far Infrared Imager and Polarimeter FIP
NASA Astrophysics Data System (ADS)
Staguhn, Johannes G.; Chuss, David; Howard, Joseph; Meixner, Margaret; Vieira, Joaquin; Amatucci, Edward; Bradley, Damon; Carter, Ruth; Cooray, Asantha; Flores, Anel; Leisawitz, David; Moseley, Samuel Harvey; Wollack, Edward; Origins Space Telescope Study Team
2018-01-01
The Origins Space Telescope (OST)* is the mission concept for the Far-Infrared Surveyor, one of the four science and technology definition studies of NASA Headquarters for the 2020 Astronomy and Astrophysics Decadal survey. The current "concept 1", which envisions a cold (4K) 9m space telescope, includes 5 instruments, providing a wavelength coverage ranging from 6um and 667um. The achievable sensitivity of the observatory will provide three to four orders of magnitude of improvement in sensitivity over current observational capabilities, allowing to address a wide range of new and so far inaccessible scientific questions, ranging from bio-signatures on exo-planets to mapping primordial H_2 from the "dark ages" before the universe went through the phase of re-ionization.Here we present the Far Infrared Imager and Polarimeter (FIP) for OST. The cameral will cover four bands, 40um, 80um, 120um, and 240um. It will allow for differential polarimetry in those bands with the ability to observe two colors in polarimtery mode simultaneously, while all four bands can be observed simultaneously in total power mode. While the confusion limit will be reached in only 32ms at 240um, at 40um the source density on the sky is so low, that at the angular resolution of 1" of OST at this wavelength there will be no source confusion, even for the longest integration times. Science topics that can be addressed by FIP include but are not limited to galactic and extragalactic magnetic field studies, Deep Galaxy Surveys, and Outer Solar System objects..*Origins will enable flagship-quality general observing programs led by the astronomical community in the 2030s. We welcome you to contact the Science and Technology Definition Team (STDT) with your science needs and ideas by emailing us at ost_info@lists.ipac.caltech.edu
NASA Astrophysics Data System (ADS)
Nalepa, N. A.; Murray, K. S.; Napieralski, J. A.
2009-12-01
According to recent studies, more than 40% of students within the Detroit Public Schools (DPS) drop out and only 21% graduate within 4 years. In an attempt to improve these statistics, The Geosciences Institute for Research and Education was developed by the University of Michigan-Dearborn (UM-D) and funded by two grants from the National Science Foundation’s (NSF) OEDG Program. The Geosciences Institute, a collaboration between the UM-D, DPS, and local corporations, aims to generate awareness of the geosciences to middle school students, facilitate an enthusiastic learning environment, encourage underrepresented minorities to stay in school, and consider the geosciences as a viable career option. This is accomplished by involving their teachers, UM-D faculty and students, and local geoscience professionals in community-based research problems relevant to SE Michigan. Students use the geosciences as a tool in which they are actively participating in research that is in their backyards. Through a mixture of field trips, participation, and demonstrational activities the students become aware of local environmental and social problems and how a background in the geosciences can prepare them. As part of the Geosciences Institute, students participate in three ongoing research projects with UM-D faculty: (1) build, install, and monitor groundwater wells along the Lower Rouge River, (2) collect soil samples from and mapping brownfields in SW Detroit, and (3) learn basic GPS and GIS skills to map local natural resources. The students also work with faculty on creating video diaries that record ideas, experiences, and impressions throughout the Institute, including during fieldtrips, modules, research, and editing. Finally, small teams of students collaborate to design and print a poster that summarizes their experience in the Institute. The Geosciences Institute concludes with a ceremony that celebrates student efforts (posters and videos) and involves school administrators and teachers, faculty, and family. It is expected that this experience will generate enthusiasm for learning before entering high school and might lead some of these underrepresented students to pursue their education at UM-D, and possibly for a career in geology.
Nulling at the Keck Interferometer
NASA Technical Reports Server (NTRS)
Colavita, M. Mark; Serabyn, Gene; Wizinowich, Peter L.; Akeson, Rachel L.
2006-01-01
The nulling mode of the Keck Interferometer is being commissioned at the Mauna Kea summit. The nuller combines the two Keck telescope apertures in a split-pupil mode to both cancel the on-axis starlight and to coherently detect the residual signal. The nuller, working at 10 um, is tightly integrated with the other interferometer subsystems including the fringe and angle trackers, the delay lines and laser metrology, and the real-time control system. Since first 10 um light in August 2004, the system integration is proceeding with increasing functionality and performance, leading to demonstration of a 100:1 on-sky null in 2005. That level of performance has now been extended to observations with longer coherent integration times. An overview of the overall system is presented, with emphasis on the observing sequence, phasing system, and differences with respect to the V2 system, along with a presentation of some recent engineering data.
2013-12-01
M TIME PPC1 Volume of Spheroid Ctrl (respective media) .2% DMSO 10 uM Free Curcumin 20 uM Free Curcumin 10 uM Tagged Curcumin 20 uM Tagged... Curcumin FIGURE 6 Ctrl media 10uM FC 20uM FC 20uM TC 10uM TC 2% DMSO PC3 t0 Div 8 FIGURE 7 Phospho-p65 NFκB subunit expression decreased In
U.S. Army unmanned aircraft systems roadmap 2010-2035
DOT National Transportation Integrated Search
2010-01-01
The Unmanned Aircraft System (UAS) Roadmap outlines how the U.S. Army will develop, organize, and employ UAS from 2010 to 2035 across full spectrum operations. The Army UAS Roadmap is nested with the Unmanned Systems (UMS) Initial Capabilities Docume...
Development and Implementation of Metrics for Identifying Military Impulse Noise
2010-09-01
False Negative Rate FP False Positive FPR False Positive Rate FtC Fort Carson, CO GIS Geographic Information System GMM Gaussian mixture model Hz...60 70 80 90 100 110 Bin Number B in N um be r N um ber of D ata Points M apped to B in 14 Figure 8. Plot of typical neuron activation...signal metrics and waveform itself were saved and transmitted to the home base. There is also a provision to download the entire recorded waveform
VizieR Online Data Catalog: The hot Jupiter Kepler-13Ab planet's occultation (Shporer+, 2014)
NASA Astrophysics Data System (ADS)
Shporer, A.; O'Rourke, J. G.; Knutson, H. A.; Szabo, G. M.; Zhao, M.; Burrows, A.; Fortney, J.; Agol, E.; Cowan, N. B.; Desert, J.-M.; Howard, A. W.; Isaacson, H.; Lewis, N. K.; Showman, A. P.; Todorov, K. O.
2017-07-01
Here we carry out an atmospheric characterization of Kepler-13Ab by measuring its occultation in four different wavelength bands, from the infrared (IR; Spitzer/Infrared array camera (IRAC) 4.5 um and 3.6 um), through the near-IR (NIR; Ks band), to the optical (Kepler). We also analyze the Kepler phase curve and obtain Keck/high-resolution echelle spectrometer (HIRES) spectra that result in revised parameters for the objects in the system. (4 data files).
Smith, Kevin A; Athey, Brian D; Chahal, Amar P S; Sahai, Priti
2008-11-06
Velos eResearch is a commercially-developed, regulatory-compliant, web-based clinical research information system from Velos Inc. Aithent Inc. is a software development services company. The University of Michigan (UM) has public/private partnerships with Velos and Aithent to collaborate on development of additional capabilities, modules, and new products to better support the needs of clinical and translational research communities. These partnerships provide UM with a mechanism for obtaining high-quality functionally comprehensive capabilities more quickly and at lower cost, while the corporate partners get a quality advisory and development partner--this benefits all parties. The UM chose to partner with Velos in part because of its commitment to interoperability. Velos is an active participant in the NCI caBIG project and is committed to caBIG compatibility. Velos already provides interoperability with other Velos sites in the CTSA context. One example of the partnership is co-development of integrated specimen management capabilities. UM spent more than a year defining business requirements and technical specifications for, and is funding development of, this capability. UM also facilitates an autonomous user community (20+ institutions, 7 CTSA awardees); the broad goal of the group is to share experiences, expertise, identify collaborative opportunities, and support one another as well as provide a source of future needs identification to Velos. Advantages and risks related to delivering informatics capabilities to an AHC research community through a public/private partnership will be presented. The UM, Velos and Aithent will discuss frameworks, agreements and other factors that have contributed to a successful partnership.
Seulimeum segment characteristic indicated by 2-D resistivity imaging method
NASA Astrophysics Data System (ADS)
Syukri, M.; Saad, R.
2017-06-01
The study conducted at Aceh (Indonesia) within Krueng Raya and Ie Seu Um vicinity with the same geology setting (Lam Teuba volcanic), to study Seulimeum Segment characteristic using 2-D resistivity imaging method. The 2-D resistivity survey applied Pole-dipole array with minimum electrode spacing of 2 and 5 m for Ie Seu Um study area, while 10 m for Krueng Raya area. Resistivity value of Ie Seu Um study area has been correlated and validated with existing outcrops and hot springs which the value used to identify overburden, saturated area and bedrock of Krueng Raya area. The resistivity value of overburden in Krueng Raya area was identify as <30 Ohm.m, bedrock is >30 Ohm.m and saturated zone is <9 Ohm.m. The imaging results used to identify the Seulimeum segment system, where the depth is increasing from southern part (20-50 m) to northern part (50-200 m) when approaching the Andaman Sea and breaks into two sections to produce horst and graben system which indicate that it produced from the moving plat.
1973 environmental monitoring report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hull, A.P.; Ash, J.A.
1974-03-01
>Results from radiation monitoring during 1973 in the environment of the Brookhaven National Laboratory are presented. Data are included on: the gross alpha and BETA activity and content of tritium and gamma-emitting radionuclides in surface air; gross BETA activity and gamma and tritium content in atmospheric precipitation; activities and concentration of gamma emitters in liquid effiuents and ground water; gross BETA , tritium and /sup 90/Sr in effluents; gross BETA and tritl um in surface waters; /sup 90/Sr and gamma- emitting radionuclides in river ecosystem; gross alpha , gross BETA , tritium, / sup 90/Sr, and /sup 137/Cs in groundmore » and well water; /sup 137/Cs, K, /sup 131/I, and /sup 90/Sr content in area milk; and gamma-emitting radionuclides in soils and grasses. (LCL)« less
In-vitro ablation of fibrocartilage by XeCl excimer laser
NASA Astrophysics Data System (ADS)
Buchelt, Martin; Papaioannou, Thanassis; Fishbein, Michael C.; Peters, Werner; Beeder, Clain; Grundfest, Warren S.
1991-07-01
A 308 nm excimer laser was employed for ablation of human fibrocartilage. Experiments were conducted in vitro. The tissue response was investigated with respect to dosimetry (ablation rate versus radiant exposure) and thermal effect (thermographic analysis). Irradiation was performed via a 600 um fiber, with radiant exposures ranging between 20mj/mm2 and 80mj/mm2, at 20Hz. The ablation rates were found to range from 3um/pulse to 80um/pulse depending on the radiant exposure and/or the applied pressure on the delivery system. Thermographic analysis, during ablation, revealed maximum average temperatures of about 65 degree(s)C. Similar measurements performed, for the purpose of comparison, with a CW Nd:YAG and a CW CO2 laser showed higher values, of the order of 200 degree(s)C.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dewald, E; Kozioziemski, B; Moody, J
2008-06-26
We use x-ray phase contrast imaging to characterize the inner surface roughness of DT ice layers in capsules planned for future ignition experiments. It is therefore important to quantify how well the x-ray data correlates with the actual ice roughness. We benchmarked the accuracy of our system using surrogates with fabricated roughness characterized with high precision standard techniques. Cylindrical artifacts with azimuthally uniform sinusoidal perturbations with 100 um period and 1 um amplitude demonstrated 0.02 um accuracy limited by the resolution of the imager and the source size of our phase contrast system. Spherical surrogates with random roughness close tomore » that required for the DT ice for a successful ignition experiment were used to correlate the actual surface roughness to that obtained from the x-ray measurements. When comparing average power spectra of individual measurements, the accuracy mode number limits of the x-ray phase contrast system benchmarked against surface characterization performed by Atomic Force Microscopy are 60 and 90 for surrogates smoother and rougher than the required roughness for the ice. These agreement mode number limits are >100 when comparing matching individual measurements. We will discuss the implications for interpreting DT ice roughness data derived from phase-contrast x-ray imaging.« less
Colors and Compositional Characteristics of Kuiper Belt Objects and Centaurs
NASA Astrophysics Data System (ADS)
Lederer, S. M.; Vilas, F.; Jarvis, K. S.; French, L.
2001-11-01
We present a study designed by Painter et al. (DPS 2000) to search for evidence of aqueous alteration in the surface material of solar system objects. Using VRI broadband photometry, we will search for the presence of the 0.7 um absorption feature (indicative of Fe-bearing hydrated silicates) in KBOs and Centaurs. Vilas (Icarus 111, 1994) found a strong correlation between the presence of the 0.7-um feature in low-albedo asteroids with solar-like colors and the 3-um water of hydration feature, indicative of phyllosilicates. Recent work by Howell et al. (LPSC, 2001) confirms that the presence of the 0.7 um feature in low-albedo asteroids definitely indicates the presence of the 3.0-um water of hydration absorption feature, suggesting the action of aqueous alteration in asteroids. In addition, Feierberg et al. (Icarus 63, 1985) showed that when the U - B color difference is > 0.12 in ECAS photometry, the 3.0-um absorption feature is often present in low albedo asteroids. Therefore, if the U-B color difference is > 0.12 and the 0.7-um feature is present in UBVRI reflectance photometry, water of hydration is implied in KBOs and Centaurs. We pursue these studies based on the mixed flat or steeply reddened photometry of these objects: Water ice has been identified in near-IR dark, flat spectra of some Centaurs, providing a source for the action of aqueous alteration. The complex collisional history proposed for these objects suggests a potential source of heating that would melt water ice, providing a mechanism for aqueous alteration to occur. Finally, we will use BVR photometry to determine the B-V and V-R colors, as has been done by Tegler and Romanishin (Nature, 407). We will compare our results with colors of KBOs and Centaurs published in the literature. This research was supported by the National Research Council and the NASA Planetary Astronomy Program.
NASA Astrophysics Data System (ADS)
Wu, Yuan-Yun
In this dissertation, fluxless silver (Ag)-indium (In) binary system bonding and Ag solid-state bonding are used between different bonded pairs which have large thermal expansion coefficient (CTE) mismatch and flip-chip interconnect bonding application. In contrast to the conventional soldering process, fluxless bonding technique eliminates contamination and reliability problems caused by flux to fabricate high quality joints. There are two section are reported. In the first section, the reactions of Ag-In binary system are presented. In the second section, the high melting temperature, thermal and electrical conductivity joint materials bonding by either Ag-In binary system bonding or solid-state bonding processes for different bonded pairs and flip-chip application are designed, developed, and reported. Our group have studied Ag-In system for several years and developed the bonding processes successfully. However, the detailed reactions of Ag and In were seldom studied. To design a proper bonding structure, it is necessary to understand the reaction between Ag and In. The systematic experiments were performed to investigate these reactions. A 40 um Ag layer was electroplated on copper (Cu) substrates, followed by indium layers of 1, 3, 5, 10, and 15 um, respectively. The samples were annealed at 180 °C in 0.1 torr vacuum. For samples with In thickness less than 5 mum, the joint compositions are Ag2In only (1 um) or AgIn2, Ag2In, and Ag solid solution (Ag) after annealing. No indium is identified. For 10 and 15 um thick In samples, In covers almost over the entire sample surface after annealing. Later, an Ag layer was annealed at 450 °C for 3 hours to grow Ag grains, followed by plating 10 um In and annealing at 180 °C. By annealing Ag before plating In, more In is kept in the structure during annealing at 180 °C. Based on above results, for those designs with In thinner than 5 um, the Ag layer needs to be annealed, prior to In plating in order to make a successful bonding. In this section, we further studied the Ag-In bonding and solid-state bonding for different bonded pairs and flip-chip application. For the silicon (Si) and aluminum (Al) pair, Al has been used as the material for interconnect pads on the ICs. However, its high CTE (23 x 10-6/°C) and non-solderable property limit its applications in electronic products. To overcome these problems, a fluxless Ag-In bonding was developed. Al was deposited Cr/Cu layer on the surface by E-beam evaporator to make it solderable. 15 um of Ag and 8 um of In were sequentially plated on the Al substrates and 15 um of Ag was on Si chips with Cr/Au coating layer. The bonding was performed at 180 °C in 0.1 torr vacuum. The joint consists of Ag/(Ag)/Ag2In/(Ag)/Ag. The joint can achieve a solidus temperature of beyond 600 °C. From shear test results, the shear strengths far exceed the requirement in MIL-STD-883H. Al is not considered as a favorable substrate material because it is not solderable and has a high CTE. The new method presented in this thesis seems to have surmounted these two challenges. Since Ag2In is weak inside the joint in Ag-In system, an annealed process was used to convert the joints into Ag solid solution (Ag) to increase the joint strength and ductility. Two copper (Cu) substrates were bonded at 180 °C without flux. Bonding samples were annealed at 200 °C for 1,000 hours (first design) and at 250 °C for 350 hours (second design), respectively. Scanning electron microscope with energy dispersive X-ray (EDX) analysis results indicate that the joint of the first design is an alloy of mostly (Ag) with micron-size Ag2In and Ag3In regions, and that of second design has converted to a single (Ag) phase. Shear test results show that the breaking forces far exceed the requirement in MIL-STD-883H. The joint solidus temperatures are 600 °C and 800 °C for the first and second designs, respectively. The research results have shown that high-strength and high temperature joints can be manufactured using fluxless low temperature processes with the Ag-In system and are valuable in developing high temperature package. (Abstract shortened by UMI.).
Attenuation of midinfrared free electron laser energy with eyewear
NASA Astrophysics Data System (ADS)
Joos, Karen M.; Gabella, William
2005-04-01
Purpose: To determine the attenuation of free electron laser (FEL) energy at several wavelengths through microscope objective and eyeglass lenses. Materials and Methods: The FEL at wavelengths of 2.3 um, 2.5 um, 3.0 um, 3.5 um, 4.0 um, 4.5 um, 5.0 um, 6.45 um, 7.0 um, 7.5 um, and 8.0 um was telescoped using a 500 mm nominal focal length lens and a 200 mm focal length lens. The beam had a final spot of about 3 mm and was passed through a 3 mm aperture and onto the 8 mm active area of a J9LP Molectron detector. The eyeglass sample was placed 3 cm in front of the detector. Energy readings were averaged over multiple pulses. Results: Attenuation varied greatly with wavelength and sample from a low attenuation of 0.46 dB, 90% transmission, for short wavelengths through common glass to greater than 60 dB attenuation (transmission at the detector noise level) for IR safe glass by Aura, Inc. Conclusion: Only the designated laser safety goggles effectively attenuate free electron laser energy at 2.3 um and 2.5 um. A microscope objective lens, polycarbonate, and silica glass eyewear is capable of effectively attenuating FEL energy at wavelengths greater than 4.5 um, but the polycarbonate lenses demonstrated material damage.
Carvalho, Lilian Regina de; Évora, Yolanda Dora Martinez; Zem-Mascarenhas, Silvia Helena
2016-08-29
to assess the usability of a digital learning technology prototype as a new method for minimally invasive monitoring of intracranial pressure. descriptive study using a quantitative approach on assessing the usability of a prototype based on Nielsen's ten heuristics. Four experts in the area of Human-Computer interaction participated in the study. the evaluation delivered eight violated heuristics and 31 usability problems in the 32 screens of the prototype. the suggestions of the evaluators were critical for developing an intuitive, user-friendly interface and will be included in the final version of the digital learning technology. avaliar a usabilidade de um protótipo educacional digital sobre um novo método para monitoração da pressão intracraniana de forma minimamente invasivo para enfermeiros e médicos. estudo descritivo com abordagem quantitativa sobre a avaliação de usabilidade de um protótipo com base nas dez Heurísticas de Nielsen. Participaram quatro especialistas da área de Interação Humano Computador. a avaliação resultou em oito heurísticas violadas e 31 problemas de usabilidade nas 32 telas do protótipo. as sugestões dos avaliadores foram cruciais para o desenvolvimento de uma interface amigável e intuitiva e serão consideradas na versão final da tecnologia educacional digital. evaluar la usabilidad de un prototipo educacional digital sobre un nuevo método para monitorización de la presión intracraneal, de manera mínimamente invasiva. estudio descriptivo con abordaje cuantitativo sobre la evaluación de usabilidad de un prototipo con base en las diez reglas Heurísticas de Nielsen. Participaron cuatro especialistas del área de Interacción Humana Computador. la evaluación resultó en ocho reglas heurísticas violadas y 31 problemas de usabilidad en las 32 pantallas del prototipo. las sugestiones de los evaluadores fueron cruciales para el desarrollo de una interfaz amigable e intuitiva y éstas serán consideradas en la versión final de la tecnología educacional digital.
VizieR Online Data Catalog: Herschel FIR spectra of GOALS galaxies (Diaz-Santos+, 2017)
NASA Astrophysics Data System (ADS)
Diaz-Santos, T.; Armus, L.; Charmandaris, V.; Lu, N.; Stierwalt, S.; Stacey, G.; Malhotra, S.; van der Werf, P. P.; Howell, J. H.; Privon, G. C.; Mazzarella, J. M.; Goldsmith, P. F.; Murphy, E. J.; Barcos-Munoz, L.; Linden, S. T.; Inami, H.; Larson, K. L.; Evans, A. S.; Appleton, P.; Iwasawa, K.; Lord, S.; Sanders, D. B.; Surace, J. A.
2018-04-01
We have obtained FIR spectroscopic observations for 200 luminous infrared galaxies (LIRG) systems from the Great Observatories All-Sky LIRG Survey (GOALS; Armus+ 2009PASP..121..559A) using the Integral Field Spectrometer (IFS) of the PACS instrument on board Herschel. Since some targets contain multiple components, there are 241 individual galaxies with available spectra in at least one emission line. Most of the data were collected as part of our OT1 and OT2 programs (OT1larmus1, OT2larmus1; P.I.: L. Armus), accounting for more than 200hr of observing time in total. Additional observations that are publicly available in the Herschel archive were included from various projects. The main programs from where these complementary data were gathered are KPGTesturm1 (P.I.: E. Sturm), KPOTpvanderw1 (PI: P. van der Werf), and OT1dweedman1 (P.I.: D. Weedman). The IFS on PACS is able to perform simultaneous spectroscopy in the 51-73 or 70-105um and the 102-210um ranges. In addition to the PACS/IFS spectra, we obtained observations of the [NII]205 emission line using the SPIRE FTS for 121 galaxies in the GOALS sample (Lu+ 2017, J/ApJS/230/1 ; OT1nlu1; P.I.: N. Lu). As part of the Spitzer GOALS legacy program, all galaxies observed with Herschel/PACS have available Spitzer/IRS low-resolution, R~60-120 (SL module: 5.2-14.5um; LL module: 14-38um), and medium-resolution, R~600 (SH module: 9.9-19.6um; LH module: 18.7-37.2um), slit spectroscopy. (3 data files).
Montanari, R M; Bangali, A M; Talukder, K R; Baqui, A; Maheswary, N P; Gosh, A; Rahman, M; Mahmood, A H
2001-01-01
In countries where malaria is endemic, routine blood slide examinations remain the major source of data for the public health surveillance system. This approach has become inadequate, however, as the public health emphasis has changed from surveillance of laboratory-confirmed malaria infections to the early detection and treatment of the disease. As a result, it has been advocated that the information collected about malaria be changed radically and should include the monitoring of morbidity and mortality, clinical practice and quality of care. To improve the early diagnosis and prompt treatment (EDPT) of malaria patients, three malaria case definitions (MCDs) were developed, with treatment and reporting guidelines, and used in all static health facilities of Cox's Bazar district, Bangladesh (population 1.5 million). The three MCDs were: uncomplicated malaria (UM); treatment failure malaria (TFM); and severe malaria (SM). The number of malaria deaths was also reported. This paper reviews the rationale and need for MCDs in malaria control programmes and presents an analysis of the integrated surveillance information collected during the three-year period, 1995-97. The combined analysis of slide-based and clinical data and their related indicators shows that blood slide analysis is no longer used to document fever episodes but to support EDPT, with priority given to SM and TFM patients. Data indicate a decrease in the overall positive predictive value of the three MCDs as malaria prevalence decreases. Hence the data quantify the extent to which the mainly clinical diagnosis of UM leads to over-diagnosis and over-treatment in changing epidemiological conditions. Also the new surveillance data show: a halving in the case fatality rate among SM cases (from 6% to 3.1%) attributable to improved quality of care, and a stable proportion of TFM cases (around 7%) against a defined population denominator. Changes implemented in the EDPT of malaria patients and in the surveillance system were based on existing staff capacity and routine reporting structures.
Care production for tuberculosis cases:analysis according to the elements of the Chronic Care Model.
Silva, Daiane Medeiros da; Farias, Hérika Brito Gomes de; Villa, Tereza Cristina Scatena; Sá, Lenilde Duarte de; Brunello, Maria Eugênia Firmino; Nogueira, Jordana de Almeida
2016-04-01
To analyze the care provided to tuberculosis cases in primary health care services according to the elements of the Chronic Care Model. Cross-sectional study conducted in a capital city of the northeastern region of Brazil involving 83 Family Health Strategy professionals.A structured tool adapted to tuberculosis-related care in Brazil was applied.Analysis was based on the development of indicators with capacity to produce care varying between limited and optimum. The organization of care for tuberculosis and supported self-care presented reasonable capacity.In the coordination with the community, the presence of the community agent presented optimum capacity.Partnership with organizations of the community and involvement of experts presented limited capacity.The qualification of professionals, the system for scheduling and monitoring tuberculosis in the community, and the clinical information system presented basic capacity. The capacity of the primary health care services to produce tuberculosis-related care according to the elements of the Chronic Care Model is still limited.Overcoming the fragmentation of care and prioritizing a systemic operation between actions and services of the health care network remains as a major challenge. Analisar,segundo os elementos doChronicCareModel,a produção do cuidado aos casos de tuberculose nos serviços de Atenção Primária à Saúde. Estudo transversal, realizado em capital do nordeste brasileiro, envolvendo 83 profissionais da Estratégia Saúde da Família. Aplicou-se um instrumento estruturado, adaptado para atenção à tuberculose no Brasil. A análise pautou-se na construção de indicadores, cujacapacidade para produção de cuidados variou entre limitada a ótima. A organização da atenção à tuberculose e o autocuidado apoiado apresentaram capacidade razoável. Na articulação com a comunidade, a presençadoagente comunitário de saúde apresentou capacidade ótima. A parceria com organizações da comunidade e o envolvimento de especialistas obtiveram capacidade limitada. A capacitação dos profissionais, o sistema de agendamento e monitoramento da tuberculose na comunidade e o sistema de informação clínica alcançaram capacidade básica. A capacidade dos serviços da Atenção Primária à Saúde para produção do cuidado aos casos de tuberculose,segundo os elementos doChronicCareModel,ainda é limitada.Superar a fragmentação do cuidado e priorizar um funcionamento sistêmico entre ações e serviços da rede de atenção à saúde é ainda um grande desafio.
Quantification of Tumor Vascular Permeability and Blood Volume by Positron Emission Tomography
Chen, Haojun; Tong, Xiao; Lang, Lixin; Jacobson, Orit; Yung, Bryant C.; Yang, Xiangyu; Bai, Ruiliang; Kiesewetter, Dale O.; Ma, Ying; Wu, Hua; Niu, Gang; Chen, Xiaoyuan
2017-01-01
Purpose: Evans Blue (EB) is an azo dye that binds quantitatively with serum albumin. With an albumin binding, NOTA conjugated truncated Evan's blue (NEB) dye derived PET tracer, we aimed to establish a strategy for evaluating vascular permeability in malignant tumors via non-invasive PET. Experimental design: Sixty-minute dynamic PET using [18F]FAl-NEB was performed in three xenograft tumor models including INS-1 rat insulinoma, UM-SCC-22B human head and neck carcinoma and U-87 MG human glioblastoma. Tumor vascular permeability was quantified by the difference of the slopes between tumor and blood time-activity curve (TACs, expressed as Ps). The method was further substantiated by EB extraction and colorimetric assay and correlates with that calculated from dynamic contrast enhanced magnetic resonance imaging (DCE-MRI). The changes in tumor vasculature at different time points were assessed with NEB PET in U-87 MG and UM-SCC-22B tumor models after treatment with bevacizumab or doxorubicin. Result: The Ps values calculated from tumor and blood TACs from multiple time-point static images are consistent with those from dynamic images. Moreover, the Ps showed a positive and significant correlation with extracted EB concentration and KPS-MRI generated from DCE-MRI, which further confirmed the soundness of this methodology. The antiangiogenic effect of bevacizumab could be revealed by NEB PET in U-87 MG tumors as early as 8 hrs after therapy, demonstrated by a substantial decrease of Ps. On the contrary, there was no significant change of Ps in bevacizumab treated UM-SCC-22B tumors, compared with control group. However, the significant changes of Pswere overestimated in doxorubicin treated UM-SCC-22B tumors. Conclusions: We successfully developed a relatively convenient and novel strategy to evaluate vascular permeability and blood volume using NEB PET. This method will be advantageous in evaluating vascular permeability, promoting drug delivery, and monitoring tumor response to therapeutics that affect tumor angiogenesis. PMID:28744320
NASA Astrophysics Data System (ADS)
Gholoum, M.; Bruce, D.; Hazeam, S. Al
2012-07-01
A coral reef ecosystem, one of the most complex marine environmental systems on the planet, is defined as biologically diverse and immense. It plays an important role in maintaining a vast biological diversity for future generations and functions as an essential spawning, nursery, breeding and feeding ground for many kinds of marine species. In addition, coral reef ecosystems provide valuable benefits such as fisheries, ecological goods and services and recreational activities to many communities. However, this valuable resource is highly threatened by a number of environmental changes and anthropogenic impacts that can lead to reduced coral growth and production, mass coral mortality and loss of coral diversity. With the growth of these threats on coral reef ecosystems, there is a strong management need for mapping and monitoring of coral reef ecosystems. Remote sensing technology can be a valuable tool for mapping and monitoring of these ecosystems. However, the diversity and complexity of coral reef ecosystems, the resolution capabilities of satellite sensors and the low reflectivity of shallow water increases the difficulties to identify and classify its features. This paper reviews the methods used in mapping and monitoring coral reef ecosystems. In addition, this paper proposes improved methods for mapping and monitoring coral reef ecosystems based on image fusion techniques. This image fusion techniques will be applied to satellite images exhibiting high spatial and low to medium spectral resolution with images exhibiting low spatial and high spectral resolution. Furthermore, a new method will be developed to fuse hyperspectral imagery with multispectral imagery. The fused image will have a large number of spectral bands and it will have all pairs of corresponding spatial objects. This will potentially help to accurately classify the image data. Accuracy assessment use ground truth will be performed for the selected methods to determine the quality of the information derived from image classification. The research will be applied to the Kuwait's southern coral reefs: Kubbar and Um Al-Maradim.
2010-04-01
Characteristics associated with “Free Flight” Shroud and Stage Separation and Mode Switching in LENS II Michael S. Holden, PhD CUBRC , Inc. 4455 Genesee...ADDRESS(ES) CUBRC , Inc. 4455 Genesee Street Buffalo, NY 14225, USA 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND...switching and inlet-starting validation • Validation to CFD community ( CUBRC /UM) Figure 32: Numerical Simulation of the Unsteady Flow Dynamics during
Real-Time Environmental Artic Monitoring (R-TEAM).
1987-11-01
critical points of the mooring. Tension, tilt, pressure and temperature data are recorded on solid state memory for the duration of the deployment. Two...To iUe Tna£ LA6aksIIorZ. Um DESCaiPTiow r oj.t.TAK 2ALUMINUM PIPE -ob.I’ -WALL. 5e1 . Sm IVI IlSdh7 Z BOT’TOM END CAPME G,15473 (5 2 R.OD 3__ MX 306 as...described in Reference 2. Each instrument, located at a critical point of the mooring, measures and records in solid state memory tension, tilt, temperature
2008-02-01
v ol um e (c m ^3 ) Injection Internal pump External Pump Treatment starts Rat’s condition before treatment 0 0.2 0.4 0.6 0.8 1 550 650...of polysilicon thermal flexure actuator,” J. of Micromechanics and Microengineering.9, 2005. [36] A. Grayson, et.al., “Electronic MEMS for...36. [59] Q-H. Huang and N. K. S. Lee, “Analysis and design of polysilicon thermal flexure actuator,” J. Micromech. Microeng. 9 (1) pp. 64–70 (1999
Code of Federal Regulations, 2011 CFR
2011-04-01
... Glass Fiber Reinforcing Mesh for Use in Exterior Insulation and Finish Systems (EIFS), Class PB. (xv... certification program for exterior finish and insulation systems, use of Materials Bulletin UM 101. 200.946... product standards and certification program for exterior finish and insulation systems, use of Materials...
Code of Federal Regulations, 2010 CFR
2010-04-01
... Glass Fiber Reinforcing Mesh for Use in Exterior Insulation and Finish Systems (EIFS), Class PB. (xv... certification program for exterior finish and insulation systems, use of Materials Bulletin UM 101. 200.946... product standards and certification program for exterior finish and insulation systems, use of Materials...
NASA Astrophysics Data System (ADS)
Wu, Hao; Yu, Jun; Cao, Rui; Yang, Yinghua; Tang, Zhenan
2018-05-01
A high-performance low-power micro hotplate (MHP) hydrogen sensor was fabricated through electrohydrodynamic (EHD) inkjet printing technique. Electrospun Pd loaded SnO2 nanofibers with lengths of 250-850 nm were precisely printed on the suspended central part of an MHP with an area of 100 um × 100 um. The printhead in the printing system was a low-cost metallic needle with an inner diameter of 110 um, which was large enough to prevent clogging by the nanofibers. The printing process was observed by a high-speed camera. Small droplets with diameters of 50-80 um were produced at each ejection by providing a high voltage to the metallic needle. It was found that the bridge-type MHPs used in our experiment can promote the positioning precision due to its bound effect to the droplet. In the gas sensing measurement, the Pd loaded SnO2 MHP gas sensor showed a remarkable response to H2 with a low power of only 9.1 mW. The experiment results demonstrate the excellent adequacy of EHD inkjet printing technique to realize effective mass fabrication of MHP gas sensors or sensor arrays.
Increased fracture depth range in controlled spalling of (100)-oriented germanium via electroplating
Crouse, Dustin; Simon, John; Schulte, Kevin L.; ...
2018-01-31
Controlled spalling in (100)-oriented germanium using a nickel stressor layer shows promise for semiconductor device exfoliation and kerfless wafering. Demonstrated spall depths of 7-60 um using DC sputtering to deposit the stressor layer are appropriate for the latter application but spall depths < 5 um may be required to minimize waste for device applications. This work investigates the effect of tuning both electroplating current density and electrolyte chemistry on the residual stress in the nickel and on the achievable spall depth range for the Ni/Ge system as a lower-cost, higher-throughput alternative to sputtering. By tuning current density and electrolyte phosphorousmore » concentration, it is shown that electroplating can successfully span the same range of spalled thicknesses as has previously been demonstrated by sputtering and can reach sufficiently high stresses to enter a regime of thickness (<7 um) appropriate to minimize substrate consumption for device applications.« less
Increased fracture depth range in controlled spalling of (100)-oriented germanium via electroplating
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crouse, Dustin; Simon, John; Schulte, Kevin L.
Controlled spalling in (100)-oriented germanium using a nickel stressor layer shows promise for semiconductor device exfoliation and kerfless wafering. Demonstrated spall depths of 7-60 um using DC sputtering to deposit the stressor layer are appropriate for the latter application but spall depths < 5 um may be required to minimize waste for device applications. This work investigates the effect of tuning both electroplating current density and electrolyte chemistry on the residual stress in the nickel and on the achievable spall depth range for the Ni/Ge system as a lower-cost, higher-throughput alternative to sputtering. By tuning current density and electrolyte phosphorousmore » concentration, it is shown that electroplating can successfully span the same range of spalled thicknesses as has previously been demonstrated by sputtering and can reach sufficiently high stresses to enter a regime of thickness (<7 um) appropriate to minimize substrate consumption for device applications.« less
Human-model hybrid Korean air quality forecasting system.
Chang, Lim-Seok; Cho, Ara; Park, Hyunju; Nam, Kipyo; Kim, Deokrae; Hong, Ji-Hyoung; Song, Chang-Keun
2016-09-01
The Korean national air quality forecasting system, consisting of the Weather Research and Forecasting, the Sparse Matrix Operator Kernel Emissions, and the Community Modeling and Analysis (CMAQ), commenced from August 31, 2013 with target pollutants of particulate matters (PM) and ozone. Factors contributing to PM forecasting accuracy include CMAQ inputs of meteorological field and emissions, forecasters' capacity, and inherent CMAQ limit. Four numerical experiments were conducted including two global meteorological inputs from the Global Forecast System (GFS) and the Unified Model (UM), two emissions from the Model Intercomparison Study Asia (MICS-Asia) and the Intercontinental Chemical Transport Experiment (INTEX-B) for the Northeast Asia with Clear Air Policy Support System (CAPSS) for South Korea, and data assimilation of the Monitoring Atmospheric Composition and Climate (MACC). Significant PM underpredictions by using both emissions were found for PM mass and major components (sulfate and organic carbon). CMAQ predicts PM2.5 much better than PM10 (NMB of PM2.5: -20~-25%, PM10: -43~-47%). Forecasters' error usually occurred at the next day of high PM event. Once CMAQ fails to predict high PM event the day before, forecasters are likely to dismiss the model predictions on the next day which turns out to be true. The best combination of CMAQ inputs is the set of UM global meteorological field, MICS-Asia and CAPSS 2010 emissions with the NMB of -12.3%, the RMSE of 16.6μ/m(3) and the R(2) of 0.68. By using MACC data as an initial and boundary condition, the performance skill of CMAQ would be improved, especially in the case of undefined coarse emission. A variety of methods such as ensemble and data assimilation are considered to improve further the accuracy of air quality forecasting, especially for high PM events to be comparable to for all cases. The growing utilization of the air quality forecast induced the public strongly to demand that the accuracy of the national forecasting be improved. In this study, we investigated the problems in the current forecasting as well as various alternatives to solve the problems. Such efforts to improve the accuracy of the forecast are expected to contribute to the protection of public health by increasing the availability of the forecast system.
Cryogenic solid Schmidt camera as a base for future wide-field IR systems
NASA Astrophysics Data System (ADS)
Yudin, Alexey N.
2011-11-01
Work is focused on study of capability of solid Schmidt camera to serve as a wide-field infrared lens for aircraft system with whole sphere coverage, working in 8-14 um spectral range, coupled with spherical focal array of megapixel class. Designs of 16 mm f/0.2 lens with 60 and 90 degrees sensor diagonal are presented, their image quality is compared with conventional solid design. Achromatic design with significantly improved performance, containing enclosed soft correcting lens behind protective front lens is proposed. One of the main goals of the work is to estimate benefits from curved detector arrays in 8-14 um spectral range wide-field systems. Coupling of photodetector with solid Schmidt camera by means of frustrated total internal reflection is considered, with corresponding tolerance analysis. The whole lens, except front element, is considered to be cryogenic, with solid Schmidt unit to be flown by hydrogen for improvement of bulk transmission.
NASA Astrophysics Data System (ADS)
Kremens, R.; Dickinson, M. B.; Hardy, C.; Skowronski, N.; Ellicott, E. A.; Schroeder, W.
2016-12-01
We have developed a wide dynamic range (24-bit) data acquisition system for collection of radiant flux density (FRFD) data from wildland fires. The data collection subsystem was designed as an Arduino `shield' and incorporates a 24-bit analog-to-digital converter, precision voltage reference, real time clock, microSD card interface, audible annuciator and interface for various digital communication interfaces (RS232, I2C, SPI, etc.). The complete radiometer system consists of our custom-designed `shield', a commercially available Arduino MEGA computer circuit board and a thermopile sensor -amplifier daughter board. Software design and development is greatly assisted by the availability of a library of public-domain, user-implemented software. The daughter board houses a 5-band radiometer using thermopiles designed for this experiment (Dexter Research Corp., Dexter, MI) to allow determination of the total FRFD from the fire (using a wide band thermopile with a KRS-5 window, 0.1 - 30 um), the FRFD as would be received by an orbital asset like MODIS (3.95 um center wavelength (CWL) and 10.95 CWL, corresponding to MODIS bands 21/22 and 31, respectively) and wider bandpass (0.1-5.5 um and 8-14 um) corresponding to the FRFD recorded by `MWIR' and `LWIR' imaging systems. We required a very wide dynamic range system in order to be able to record the flux density from `cold' ground before the fire, through the `hot' flaming combustion stage, to the `cool' phase after passage of the fire front. The recording dynamic range required (with reasonable resolution at the lowest temperatures) is on the order of 106, which is not currently available in commercial instrumentation at a price point, size or feature set that is suitable for wildland fire investigations. The entire unit, along with rechargeable battery power supply is housed in a fireproof aluminum chassis box, which is then mounted on a mast at a height of 5 - 7 m above the fireground floor. We will report initial results on observation of wildland fires using this system for prescribed fires in the pitch-pine scrub oak forest type and the use of the system to determine the differences between actual and remotely sensed measures of FRFD, which is of importance in quantifying the release of CO2 and other fire products from wildland fire combustion.
NASA Astrophysics Data System (ADS)
Szabo, Zoltan; Oden, Jeannette H.; Gibs, Jacob; Rice, Donald E.; Ding, Yuan
2002-02-01
Particulates that move with ground water and those that are artificially mobilized during well purging could be incorporated into water samples during collection and could cause trace-element concentrations to vary in unfiltered samples, and possibly in filtered samples (typically 0.45-um (micron) pore size) as well, depending on the particle-size fractions present. Therefore, measured concentrations may not be representative of those in the aquifer. Ground water may contain particles of various sizes and shapes that are broadly classified as colloids, which do not settle from water, and particulates, which do. In order to investigate variations in trace-element concentrations in ground-water samples as a function of particle concentrations and particle-size fractions, the U.S. Geological Survey, in cooperation with the U.S. Air Force, collected samples from five wells completed in the unconfined, oxic Kirkwood-Cohansey aquifer system of the New Jersey Coastal Plain. Samples were collected by purging with a portable pump at low flow (0.2-0.5 liters per minute and minimal drawdown, ideally less than 0.5 foot). Unfiltered samples were collected in the following sequence: (1) within the first few minutes of pumping, (2) after initial turbidity declined and about one to two casing volumes of water had been purged, and (3) after turbidity values had stabilized at less than 1 to 5 Nephelometric Turbidity Units. Filtered samples were split concurrently through (1) a 0.45-um pore size capsule filter, (2) a 0.45-um pore size capsule filter and a 0.0029-um pore size tangential-flow filter in sequence, and (3), in selected cases, a 0.45-um and a 0.05-um pore size capsule filter in sequence. Filtered samples were collected concurrently with the unfiltered sample that was collected when turbidity values stabilized. Quality-assurance samples consisted of sequential duplicates (about 25 percent) and equipment blanks. Concentrations of particles were determined by light scattering.
Impact of Tile Drainage on the Distribution of Concentration and Age of Inorganic Soil Nitrogen.
NASA Astrophysics Data System (ADS)
Woo, D.; Kumar, P.
2017-12-01
Extensive network of tile drainage network across the Midwestern United States, northern Europe and other regions of the world have enhanced agricultural productivity. Because of its impact on sub-surface flow patterns and moisture and temperature dynamics, it controls the nitrogen cycle in agricultural systems, and its influence on nitrogen dynamics plays a key role in determining the short- and long-term evolution of soil inorganic nitrogen concentration and age. The spatial mapping of nitrogen concentration and age under tile-drained fields has, therefore, the potential to open up novel solution to the vexing challenge of reducing environmental impacts while at the same time maintaining agricultural productivity. The objective of this study is to explore the impacts of tile drains on the age dynamics of nitrate, immobile ammonium, mobile ammonia/um, and non-reactive tracer (such as chloride) by implementing two mobile interacting pore domains to capture matrix and preferential flow paths in a coupled ecohydrology and biogeochemistry model, Dhara. We applied this model to an agricultural farm supporting a corn-soybean rotation in the Midwestern United States. It should be expected that the installation of tile drains decrease the age of soil nutrient due to nutrient losses through tile drainage. However, an increase in the age of mobile ammonia/um is observed in contrast to the cases for nitrate, immobile ammonium, and non-reactive tracer. These results arise because the depletion of mobile ammonia/um due to tile drainage causes a high mobility flux from immobile ammonium to mobile ammonia/um, which also carries a considerable amount of relatively old age of immobile ammonium to mobile ammonia/um. In addition, the ages of nitrate and mobile ammonia/um in tile drainage range from 1 to 3 years, and less than a year, respectively, implying that not considering age transformations between nitrogen species would result in substantial underestimation of nitrogen ages, possibly leading to an erroneous conclusion.
NASA Astrophysics Data System (ADS)
Albuquerque, Daniel Filipe
Esta tese apresenta um sistema de localizacao baseado exclusivamente em ultrassons, nao necessitando de recorrer a qualquer outra tecnologia. Este sistema de localizacao foi concebido para poder operar em ambientes onde qualquer outra tecnologia nao pode ser utilizada ou o seu uso esta condicionado, como sao exemplo aplicacoes subaquaticas ou ambientes hospitalares. O sistema de localizacao proposto faz uso de uma rede de farois fixos permitindo que estacoes moveis se localizem. Devido a necessidade de transmissao de dados e medicao de distancias foi desenvolvido um pulso de ultrassons robusto a ecos que permite realizar ambas as tarefas com sucesso. O sistema de localizacao permite que as estacoes moveis se localizem escutando apenas a informacao em pulsos de ultrassons enviados pelos farois usando para tal um algoritmo baseado em diferencas de tempo de chegada. Desta forma a privacidade dos utilizadores e garantida e o sistema torna-se completamente independente do numero de utilizadores. Por forma a facilitar a implementacao da rede de farois apenas sera necessario determinar manualmente a posicao de alguns dos farois, designados por farois ancora. Estes irao permitir que os restantes farois, completamente autonomos, se possam localizar atraves de um algoritmo iterativo de localizacao baseado na minimizacao de uma funcao de custo. Para que este sistema possa funcionar como previsto sera necessario que os farois possam sincronizar os seus relogios e medir a distancia entre eles. Para tal, esta tese propoe um protocolo de sincronizacao de relogio que permite tambem obter as medidas de distancia entre os farois trocando somente tres mensagens de ultrassons. Adicionalmente, o sistema de localizacao permite que farois danificados possam ser substituidos sem comprometer a operabilidade da rede reduzindo a complexidade na manutencao. Para alem do mencionado, foi igualmente implementado um simulador de ultrassons para ambientes fechados, o qual provou ser bastante preciso e uma ferramenta de elevado valor para simular o comportamento do sistema de localizacao sobre condicoes controladas.
NASA Astrophysics Data System (ADS)
Park, Moon-Soo; Park, Sung-Hwa; Chae, Jung-Hoon; Choi, Min-Hyeok; Song, Yunyoung; Kang, Minsoo; Roh, Joon-Woo
2017-04-01
To improve our knowledge of urban meteorology, including those processes applicable to high-resolution meteorological models in the Seoul Metropolitan Area (SMA), the Weather Information Service Engine (WISE) Urban Meteorological Observation System (UMS-Seoul) has been designed and installed. The UMS-Seoul incorporates 14 surface energy balance (EB) systems, 7 surface-based three-dimensional (3-D) meteorological observation systems and applied meteorological (AP) observation systems, and the existing surface-based meteorological observation network. The EB system consists of a radiation balance system, sonic anemometers, infrared CO2/H2O gas analyzers, and many sensors measuring the wind speed and direction, temperature and humidity, precipitation, and air pressure. The EB-produced radiation, meteorological, and turbulence data will be used to quantify the surface EB according to land use and to improve the boundary-layer and surface processes in meteorological models. The 3-D system, composed of a wind lidar, microwave radiometer, aerosol lidar, or ceilometer, produces the cloud height, vertical profiles of backscatter by aerosols, wind speed and direction, temperature, humidity, and liquid water content. It will be used for high-resolution reanalysis data based on observations and for the improvement of the boundary-layer, radiation, and microphysics processes in meteorological models. The AP system includes road weather information, mosquito activity, water quality, and agrometeorological observation instruments. The standardized metadata for networks and stations are documented and renewed periodically to provide a detailed observation environment. The UMS-Seoul data are designed to support real-time acquisition and display and automatically quality check within 10 min from observation. After the quality check, data can be distributed to relevant potential users such as researchers and policy makers. Finally, two case studies demonstrate that the observed data have a great potential to help to understand the boundary-layer structures more deeply, improve the performance of high-resolution meteorological models, and provide useful information customized based on the user demands in the SMA.
Female Reproductive System (For Teens)
... uterus, called the endometrium (pronounced: en-doh-MEE-tree-um). The hormone estrogen causes the endometrium to ... may be necessary. endometriosis (pronounced: en-doh-mee-tree-OH-sus), when tissue normally found only in ...
CNN universal machine as classificaton platform: an art-like clustering algorithm.
Bálya, David
2003-12-01
Fast and robust classification of feature vectors is a crucial task in a number of real-time systems. A cellular neural/nonlinear network universal machine (CNN-UM) can be very efficient as a feature detector. The next step is to post-process the results for object recognition. This paper shows how a robust classification scheme based on adaptive resonance theory (ART) can be mapped to the CNN-UM. Moreover, this mapping is general enough to include different types of feed-forward neural networks. The designed analogic CNN algorithm is capable of classifying the extracted feature vectors keeping the advantages of the ART networks, such as robust, plastic and fault-tolerant behaviors. An analogic algorithm is presented for unsupervised classification with tunable sensitivity and automatic new class creation. The algorithm is extended for supervised classification. The presented binary feature vector classification is implemented on the existing standard CNN-UM chips for fast classification. The experimental evaluation shows promising performance after 100% accuracy on the training set.
Collective Behavior of Amoebae in Thin Films
NASA Astrophysics Data System (ADS)
Bae, Albert
2005-03-01
We have discovered new aspects of social behavior in Dictyostelium discoideum by culturing high density colonies in liquid media depleted of nutrients in confined geometries by using three different preparations: I. thin (15-40um thick) and II. ultrathin (<3um) films of liquid media with a mineral oil overlayer, and III. microfluidic chambers fabricated in PDMS (˜7um tall). We find greatly reduced, if not eliminated, cell on cell layering in the microfluidic system when compared to the wetting layer preparations. The ultrathin films reveal robust behavior of cells despite flattening that increased their areas by over an order of magnitude. We also observed that the earliest synchronized response of cells following the onset of starvation, a precursor to aggregation, was hastened by reducing the thickness of the aqueous culture layer. We were surprised to find that the threshold concentration for aggregation was raised by thin film confinement when compared to bulk behavior. Finally, both the ultra thin and microfluidic preparations reveal, with new clarity, vortex states of aggregation.
Student Outcomes: Annual Summary Report.
ERIC Educational Resources Information Center
Prince George's Community Coll., Largo, MD. Office of Institutional Research.
Each year a study is conducted at Prince George's Community College (PGCC) to update student outcomes data using quantifiable measures of student achievement. Data for the 1989 study were obtained from the college's student information system, the University of Maryland (UM) system, and surveys of all 825 fiscal year 1988 graduates and 118 of…
NASA Astrophysics Data System (ADS)
Zemek, P. G.
2017-12-01
Quantum Cascade Lasers (QCLs) are quickly replacing Tunable Diode Lasers (TDL) for multi-target species identification and quantification in both extractive and open-path (OP) Optical Remote Sensing (ORS) fence-line instrumentation. As was seen with TDL incorporation and pricing drops as the adoption by the telecommunications industry and its current scaling has improved robustness and pricing, the QCL is also, albiet more slowly, becoming a mature market. There are several advantages of QCLs over conventional TDLs such as improved brightness and beam density, high resolution, as well as the incorporation of external etalons or internal gratings to scan over wide spectral areas. QCLs typically operate in the Mid infra-red (MIR) as opposed to the Near-Infrared (NIR) region used with TDL. The MidIR is a target rich absorption band area where compounds have high absorbtivity coefficients resulting in better detection limits as compared to TDL instruments. The use of novel chemometrics and more sensitive non-cryo-cooled detectors has allowed some of the first QCL open-path instruments in both active and passive operation. Data and field studies of one of the newest QCL OP systems is presented that allows one system to measure multiple target compounds. Multiple QCL spectral regions may be stitched together to increase the capability of QCLs over TDL OP systems. A comparison of several ORS type systems will be presented.
Gravells, P; Hoh, L; Canovas, D; Rennie, I G; Sisley, K; Bryant, H E
2011-01-01
Background: Uveal melanoma (UM) is the most common primary intraocular tumour of adults, frequently metastasising to the liver. Hepatic metastases are difficult to treat and are mainly unresponsive to chemotherapy. To investigate why UM are so chemo-resistant we explored the effect of interstrand cross-linking agents mitomycin C (MMC) and cisplatin in comparison with hydroxyurea (HU). Methods: Sensitivity to MMC, cisplatin and HU was tested in established UM cell lines using clonogenic assays. The response of UM to MMC was confirmed in MTT assays using short-term cultures of primary UM. The expression of cytochrome P450 reductase (CYP450R) was analysed by western blotting, and DNA cross-linking was assessed using COMET analysis supported by γ-H2AX foci formation. Results: Both established cell lines and primary cultures of UM were resistant to the cross-linking agent MMC (in each case P<0.001 in Student's t-test compared with controls). In two established UM cell lines, DNA cross-link damage was not induced by MMC (in both cases P<0.05 in Students's t-test compared with damage induced in controls). In all, 6 out of 6 UMs tested displayed reduced expression of the metabolising enzyme CYP450R and transient expression of CYP450R increased MMC sensitivity of UM. Conclusion: We suggest that reduced expression of CYP450R is responsible for MMC resistance of UM, through a lack of bioactivation, which can be reversed by complementing UM cell lines with CYP450R. PMID:21386838
Development and Applications of the GOES Sounder Products
NASA Astrophysics Data System (ADS)
Li, Jun; Menzel, W. P.; Li, Z.; Wade, G.; Schmit, T. J.; Li, J. L.; Aune, R.; Schreiner, A. J.; Schmidt, C. C.; Genkova, I.
Since 1994 a new generation of Geostationary Operational Environmental Satellite GOES Sounders GOES-8 9 10 11 12 has been measuring radiances in 18 infrared spectral bands ranging from approximately 3 7um - 14 7 um This data has been used to provide atmospheric sounding and cloud products for meteorological applications on an hourly basis over North America and adjacent oceanic regions The products include atmospheric temperature and moisture profiles total precipitable water cloud-top pressure water-vapor tracked winds etc Products are generated operationally by NOAA NESDIS in Washington D C Some Sounder products including total column ozone are also produced at the Cooperative Institute for Meteorological Satellite Studies at the University of Wisconsin-Madison Applications of those products include nowcasting and forecasting of weather events assimilation of cloud products into regional numerical forecast models and monitoring of temperature and moisture changes during active convective periods The impact of GOES Sounder products on numerical model forecasts will be demonstrated Furthermore recent improvements to several of the products have been made by taking into account the GOES Sounder temporal and spatial information within the processing algorithms These improvements and implications thereof will be presented and discussed
NASA Astrophysics Data System (ADS)
Iria Machado, Daniel
2013-07-01
The apparent motion of the Sun on the celestial sphere and the behavior of the shadows of objects over time are observable phenomena in everyday life. However, students often do not have a proper understanding of such occurrences, and can even display misconceptions about them. Therefore, we performed a research in order to know students' notions about these subjects and to evaluate the contribution to their understanding brought about by an activity performed with an interactive sundial in an informal learning environment. We investigated the ideas of 43 students from the seventh grade of middle school by applying a test with open questions before and after an activity with an analemmatic sundial, conducted by a monitor. A significant proportion of students were initially unaware of most of the phenomena treated. The intervention performed helped the students to assimilate new concepts, providing the contact with new phenomena and to a lesser degree, the development of explanations about them, indicating an educational potential of this action. However, the contribution to the understanding of some of the ideas explored was small, pointing to the need to make additional observations, studies and discussions. O movimento aparente do Sol na esfera celeste e o comportamento das sombras dos objetos com o passar do tempo são fenômenos observáveis no dia a dia. No entanto, muitas vezes os estudantes não possuem uma compreensão adequada de tais ocorrências, podendo inclusive exibir concepções alternativas a seu respeito. Por isso, efetuou-se uma pesquisa com o intuito de conhecer as noções dos alunos sobre esses temas e avaliar a contribuição para seu entendimento propiciada por uma atividade feita com um relógio de Sol interativo, em um ambiente de ensino informal. Foram investigadas as ideias de 43 alunos do sétimo ano do Ensino Fundamental mediante a aplicação de um teste com questões abertas antes e depois de uma atividade com um relógio de Sol analemático, conduzida por um monitor. Uma proporção significativa de estudantes desconhecia inicialmente a maioria dos fenômenos tratados. A intervenção realizada colaborou para uma parte dos alunos assimilar novos conceitos, propiciando o contato com novos fenômenos e, em menor grau, a elaboração de explicações a respeito destes, indicando um potencial educativo dessa ação. Porém, a contribuição para o entendimento de algumas das ideias exploradas foi pequena, apontando para a necessidade de se fazer observações, estudos e discussões complementares. El movimiento aparente del Sol en la esfera celeste y el comportamiento de las sombras de los objetos a lo largo del tiempo son fenómenos observables en la vida cotidiana. Sin embargo, los estudiantes a menudo no tienen una adecuada comprensión de dichos problemas, e incluso pueden mostrar conceptos erróneos acerca de ellos. Por lo tanto, se realizó una investigación a fin de conocer las nociones de los estudiantes acerca de estas cuestiones y evaluar la contribución a su comprensión proporcionada por una actividad realizada con un reloj de Sol interactivo, en un entorno informal de aprendizaje. Se investigaron las ideas de 43 estudiantes del séptimo grado del ciclo primario mediante la aplicación de un test con preguntas abiertas antes y después de una actividad con un reloj de Sol analemático, dirigida por un monitor. Una proporción significativa de los estudiantes inicialmente desconocía la mayoría de los fenómenos tratados. La intervención realizada contribuyó para que los estudiantes asimilasen nuevos conceptos, proporcionando el contacto con nuevos fenómenos y, en menor medida, desarrollasen explicaciones acerca de estos, lo que indica un potencial educativo de esta acción. Sin embargo, la contribución a la comprensión de algunas de las ideas exploradas fue pequeña, lo que apunta a la necesidad de hacer observaciones, estudios y debates adicionales.
Practice, awareness and opinion of pharmacists toward disposal of unwanted medications in Kuwait
Abahussain, Eman; Waheedi, Mohammad; Koshy, Samuel
2012-01-01
Background The disposal of unwanted medications has been a concern in many countries, as pharmaceutical waste enters the ecosystem, ultimately having an effect on human health and environment. Earlier studies in Kuwait found that the method of disposal by the public was by disposing in the garbage or by flushing down the drain. In accordance with patient preference and environment safety, it would be appropriate to use local government pharmacies as collection points for proper disposal. Objective To determine the practice of pharmacists, working in government healthcare sectors, with regard to disposal of returned unwanted medications by the public. This study also aims to assess pharmacists’ awareness toward the impact of improper disposal on the environment and to investigate whether pharmacists agree to have their pharmacies as collection points for future take-back programs. Method A random sample of 144 pharmacists from the six main governmental hospitals and 12 specialized polyclinics in Kuwait, completed a self-administered questionnaire about their practice of disposal, awareness and opinion on using pharmacies as collection points for proper disposal of UMs. Data were analyzed using descriptive statistics. Results A total of 144 pharmacists completed the survey. Throwing UMs in the trash was the main method of disposal by majority of the respondents (73%). Only 23 pharmacists disposed UMs according to the guidelines of Ministry of Health, Kuwait (MOH). However, about 82% are aware that improper disposal causes damage to the environment and 97% agree that it is their responsibility to protect the environment. About 86–88% of the pharmacists agree to have government hospital pharmacies and polyclinics as collection points for future take-back programs. Conclusion Even though the current practice of disposal by majority of pharmacists is inappropriate, they are aware of the damage and acknowledge their responsibilities toward environment protection. Concerned authorities should monitor and implement proper disposal guidelines in all pharmacies. Majority of pharmacists support the idea of having the government pharmacies as collection points for safe disposal of UMs in Kuwait. PMID:23960793
Use of milk amyloid A in the diagnosis of subclinical mastitis in dairy ewes.
Miglio, Arianna; Moscati, Livia; Fruganti, Gabriele; Pela, Michela; Scoccia, Eleonora; Valiani, Andrea; Maresca, Carmen
2013-11-01
Subclinical mastitis (SM) is one of the most important diseases affecting dairy ewes worldwide, with negative impact on the animal health, farm income and public health. Animals with SM often remain untreated because the disease may not be revealed. Increase in somatic cell count (SCC) and positive bacteriology for mastitis pathogens in milk samples are indicative of SM but the evidence of only one of these alterations must suggest an uncertain SM (UM). UM is defined when positive bacteriological examination (Latent-SM) or SCC>500 000 cells/ml (non-specific-SM) are detected in milk. Nevertheless, SCC and bacteriological examination are expensive, time consuming and are not yet in use at the farm level in dairy ewes. Recently, a sensitive acute phase protein, amyloid A, displaying multiple isoforms in plasma and different body fluids including mammary secretion (milk amyloid A-MAA), has been investigated as a marker of mastitis in cows and, in a few studies, in sheep. The aim of this trial was to compare the concentration of MAA of single udder-halves in ewes with healthy udder-halves (HU-control group) and naturally occurring subclinical mastitis, both confirmed (SM group) and uncertain (UM groups: Latent-SM and non-specific-SM), for monitoring udder health. The reliability of a specific ELISA kit for the measurement of MAA was also tested. During a 3-month trial period, 153 udder halves were assigned to the experimental groups based on their health status: 25 with SM, 40 with UM (11 with latent-SM and 29 with non-specific-SM) and 88 HU. SCC and bacteriological analysis were performed to establish the control and subclinical mastitis groups. MAA concentrations in milk samples were measured using a specific commercially milk ELISA kit. The data were submitted to statistical analysis. Significant (P<0·05) differences among the groups SM, non-specific-SM and HU were detected with the SM having the highest level and HU the lowest. MAA concentration is affected by the udder health status and is a useful indicator of subclinical mastitis and increased SCC in sheep.
NASA Astrophysics Data System (ADS)
Kredzinski, Lukasz; Connelly, Michael J.
2012-06-01
Full-field Optical coherence tomography is an en-face interferometric imaging technology capable of carrying out high resolution cross-sectional imaging of the internal microstructure of an examined specimen in a non-invasive manner. The presented system is based on competitively priced optical components available at the main optical communications band located in the 1550 nm region. It consists of a superluminescent diode and an anti-stokes imaging device. The single mode fibre coupled SLD was connected to a multi-mode fibre inserted into a mode scrambler to obtain spatially incoherent illumination, suitable for OCT wide-field modality in terms of crosstalk suppression and image enhancement. This relatively inexpensive system with moderate resolution of approximately 24um x 12um (axial x lateral) was constructed to perform a 3D cross sectional imaging of a human tooth. To our knowledge this is the first 1550 nm full-field OCT system reported.
NASA Astrophysics Data System (ADS)
Ogata, Tomomichi; Johnson, Stephanie J.; Schiemann, Reinhard; Demory, Marie-Estelle; Mizuta, Ryo; Yoshida, Kohei; Osamu Arakawa
2017-11-01
In this study, we compare the resolution sensitivity of the Asian Summer Monsoon (ASM) in two Atmospheric General Circulation Models (AGCMs): the MRI-AGCM and the MetUM. We analyze the MetUM at three different resolutions, N96 (approximately 200-km mesh on the equator), N216 (90-km mesh) and N512 (40-km mesh), and the MRI-AGCM at TL95 (approximately 180-km mesh on the equator), TL319 (60-km mesh), and TL959 (20-km mesh). The MRI-AGCM and the MetUM both show decreasing precipitation over the western Pacific with increasing resolution, but their precipitation responses differ over the Indian Ocean. In MRI-AGCM, a large precipitation increase appears off the equator (5-20°N). In MetUM, this off-equatorial precipitation increase is less significant and precipitation decreases over the equator. Moisture budget analysis demonstrates that a changing in moisture flux convergence at higher resolution is related to the precipitation response. Orographic effects, intra-seasonal variability and the representation of the meridional thermal gradient are explored as possible causes of the resolution sensitivity. Both high-resolution AGCMs (TL959 and N512) can represent steep topography, which anchors the rainfall pattern over south Asia and the Maritime Continent. In MRI-AGCM, representation of low pressure systems in TL959 also contributes to the rainfall pattern. Furthermore, the seasonal evolution of the meridional thermal gradient appears to be more accurate at higher resolution, particularly in the MRI-AGCM. These findings emphasize that the impact of resolution is only robust across the two AGCMs for some features of the ASM, and highlights the importance of multi-model studies of GCM resolution sensitivity.
Wang, Panpan; Ge, Lei; Yan, Mei; Song, Xianrang; Ge, Shenguang; Yu, Jinghua
2012-02-15
In this study, electrochemical immunoassay was introduced into the recently proposed microfluidic paper-based analytical device (μPADs). To improve the performance of electrochemical immunoassay on μPAD for point-of-care testing (POCT), a novel wax-patterned microfluidic paper-based three-dimensional electrochemical device (3D-μPED) was demonstrated based on the multi-walled carbon nanotubes (MWCNTs) modified μPAD. Using typical HRP-O-Phenylenediamine-H(2)O(2) electrochemical system, a sandwich immunoassay on this 3D-μPED for sensitive diagnosis of two tumor markers simultaneously in real clinical serum samples was developed with a linear range of 0.001-75.0 UmL(-1) for cancer antigen 125 and 0.05-50.0 ngmL(-1) for carcinoembryonic antigen. In addition, this 3D-μPED can be easily integrated and combined with the recently emerging paper electronics to further develop simple, sensitive, low-cost, disposable and portable μPAD for POCT, public health and environmental monitoring in remote regions, developing or developed countries. Copyright © 2011 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Close, L. M.; Merline, W. J.; Tholen, D.; Owen, T.; Roddier, F.; Dumas, C.
1999-12-01
We outline two separate projects which highlight the power of adaptive optics (AO) to aid planetary research. The first project utilized AO to resolve the Pluto-Charon system by producing 0.15" FWHM images. We used the University of Hawaii AO system (Roddier et al. PASP 103, 131,1991) at CFHT to obtain deep (20 min) narrow band images in/out the molecular bands of water and methane ices. Our images confirm that the variation of Pluto's albedo is mainly governed by the presence of methane ice over its surface, resulting in a lower albedo at 2.26 um than at 2.02 um. Our observations confirm also that Charon is mostly covered with water-ice (Buie et al. NATURE 329, 522,1987). See Tholen et al. (ICARUS submitted) for more details on these AO results. In another application of AO, we discovered a moon around asteroid 45 Eugenia by use of the PUEO AO facility at CFHT (Rigaut et al. PASP 110, 152, 1998). With PUEO we preformed a search for asteroidal satellites among two dozen asteroids, achieving moderate Strehl ratios (35%) and FWHM of about 0.12" at H band. During this survey, we detected a faint close companion to 45 Eugenia. The satellite was 6.14 magnitudes (at 1.65 um) fainter and located at most 0.75" from Eugenia. Without the ability of AO (to sharpen the contrast and increase the resolution to 0.1"), the detection of this companion would have been impossible with ground based-telescopes. The companion was found to be in a 1200 km circular orbit with a period of 4.7 days. A more detailed discussion of this new satellite is given by Merline et al. in this volume. Adaptive optics is entering a powerful new age as all the major ground based large telescopes are developing facility AO systems. Planetary astronomy is particularly well posed to take advantage of the diffraction-limited, near-IR images (0.050" FWHM) that will become commonplace at all 8 m facilities in the near future (It is already occurring on the KECK and GEMINI-North telescopes). In particular, we review plans for the NAOS/CONICA AO facility instrument at the ESO 8m VLT that will have first light in late 2000. It is planned that NAOS/CONICA will obtain K-band Strehl ratios of 60% with reference objects (extended up to 3") of brightness V=13 (or brighter). The instrument will allow guiding on faint V=15 sources (with Strehls 20 well as tracking planetary targets that have a velocity different from the guide source. The ability to carry out remote service observing and an automatic data reduction pipeline will make the ESO VLT AO system ideal for monitoring temporal changes in planetary targets and carrying out targets of opportunity programs in general. These AO observations were made possible by support from the NSF, NASA, SwRI, and ESO.
The next generation in optical transport semiconductors: IC solutions at the system level
NASA Astrophysics Data System (ADS)
Gomatam, Badri N.
2005-02-01
In this tutorial overview, we survey some of the challenging problems facing Optical Transport and their solutions using new semiconductor-based technologies. Advances in 0.13um CMOS, SiGe/HBT and InP/HBT IC process technologies and mixed-signal design strategies are the fundamental breakthroughs that have made these solutions possible. In combination with innovative packaging and transponder/transceiver architectures IC approaches have clearly demonstrated enhanced optical link budgets with simultaneously lower (perhaps the lowest to date) cost and manufacturability tradeoffs. This paper will describe: *Electronic Dispersion Compensation broadly viewed as the overcoming of dispersion based limits to OC-192 links and extending link budgets, *Error Control/Coding also known as Forward Error Correction (FEC), *Adaptive Receivers for signal quality monitoring for real-time estimation of Q/OSNR, eye-pattern, signal BER and related temporal statistics (such as jitter). We will discuss the theoretical underpinnings of these receiver and transmitter architectures, provide examples of system performance and conclude with general market trends. These Physical layer IC solutions represent a fundamental new toolbox of options for equipment designers in addressing systems level problems. With unmatched cost and yield/performance tradeoffs, it is expected that IC approaches will provide significant flexibility in turn, for carriers and service providers who must ultimately manage the network and assure acceptable quality of service under stringent cost constraints.
Assessment of Near-Source Air Pollution at a Fine Spatial ...
Mobile monitoring is an emerging strategy to characterize spatially and temporally variable air pollution in areas near sources. EPA’s Geospatial Monitoring of Air Pollution (GMAP) vehicle – an all-electric vehicle measuring real-time concentrations of particulate and gaseous pollutants – was used to map air pollution levels near the Port of Charleston in South Carolina. High-resolution monitoring was performed along driving routes near several port terminals and rail yard facilities, recording geospatial coordinates and concentrations of pollutants including black carbon, size-resolved particle count ranging from ultrafine to coarse (6 nm to 20 um), carbon monoxide, carbon dioxide, and nitrogen dioxide. Additionally, a portable meteorological station was used to characterize local conditions. The primary objective of this work is to characterize the impact of port facilities on local scale air quality. It is found that elevated concentration measurements of Black Carbon and PM correlate to periods of increased port activity and a significant elevation in concentration is observed downwind of ports. However, limitations in study design prevent a more complete analysis of the port effect. As such, we discuss the ways in which this study is limited and how future work could be improved. Mobile monitoring is an emerging strategy to characterize spatially and temporally variable air pollution in areas near sources. EPA’s Geospatial Monitoring of Air Pollut
NASA Astrophysics Data System (ADS)
James, B. L.; Tsamis, Y. G.; Barlow, M. J.; Walsh, J. R.; Westmoquette, M. S.
2013-01-01
Using Very Large Telescope/Fibre Large Array Multi Element Spectrograph optical integral field unit observations, we present a detailed study of UM 448, a nearby blue compact galaxy (BCG) previously reported to have an anomalously high N/O abundance ratio. New Technology Telescope/Superb-Seeing Imager images reveal a morphology suggestive of a merger of two systems of contrasting colour, whilst our Hα emission maps resolve UM 448 into three separate regions that do not coincide with the stellar continuum peaks. UM 448 exhibits complex emission line profiles, with most lines consisting of a narrow [full width at half-maximum (FWHM) ≲ 100 km s-1], central component, an underlying broad component (FWHM ˜ 150-300 km s-1) and a third, narrow blueshifted component. Radial velocity maps of all three components show signs of solid body rotation across UM 448, with a projected rotation axis that correlates with the continuum morphology of the galaxy. A spatially resolved, chemodynamical analysis, based on the [O iii] λλ4363, 4959, [N ii] λ6584, [S ii] λλ6716, 6731 and [Ne iii] λ3868 line maps, is presented. Whilst the eastern tail of UM 448 has electron temperatures (Te) that are typical of BCGs, we find a region within the main body of the galaxy where the narrow and broad [O iii] λ4363 line components trace temperatures differing by 5000 K and oxygen abundances differing by 0.4 dex. We measure spatially resolved and integrated ionic and elemental abundances for O, N, S and Ne throughout UM 448, and find that they do not agree, possibly due the flux weighting of Te from the integrated spectrum. This has significant implications for abundances derived from long-slit and integrated spectra of star-forming galaxies in the nearby and distant universe. A region of enhanced N/O ratio is indeed found, extended over a ˜0.6 kpc2 region within the main body of the galaxy. Contrary to previous studies, however, we do not find evidence for a large Wolf-Rayet (WR) population, and conclude that WR stars alone cannot be responsible for producing the observed N/O excess. Instead, the location and disturbed morphology of the N-enriched region suggest that interaction-induced inflow of metal-poor gas may be responsible.
NASA Astrophysics Data System (ADS)
Alin, S. R.; Aalto, R.; Remington, S. M.; Richey, J. E.
2003-12-01
The Fly-Strickland fluvial dispersal system comprises one of the largest river basins in tropical Oceania, ranking among the top 20 rivers in the world for water and sediment discharge. From the New Guinea highlands, these rivers flow >1000 km across lowland tropical floodplains to the Gulf of Papua, with an average annual depth of runoff 100 times that of the Amazon. Within the system, the Strickland has greater sediment discharge and a steeper gradient than the Fly, providing an opportunity to investigate biogeochemical differences associated with particulate flux. For eight lowland sites across the Fly-Strickland river system, we analyzed water and suspended sediment (SS) samples for an initial survey of various carbon cycle parameters. Both the Fly and Strickland Rivers were strongly supersaturated with carbon dioxide (2008-10,479 uatm CO2) and undersaturated with oxygen (1.10-5.48 mg/l O2), with the Fly having higher CO2 and lower O2 concentrations than the Strickland River. These pCO2 and O2 concentrations are comparable to and lower than (respectively) typical values in the Amazon. Measured Fly-Strickland alkalinity values fell in the range of 0.893-1.888 meq, and pH measurements were neutral to slightly alkaline (6.916-7.852). In a sample from a sediment-impoverished tributary from Lake Murray to the Strickland (Herbert R.), pH was neutral (7.060), and alkalinity and pCO2 had their lowest observed values at 0.234 meq and 1407 uatm, respectively. Nutrient concentrations were generally higher in the Strickland ([NO3]=3.36+/-0.69 uM, [PO4]=0.09+/-0.10 uM, and [Si(OH)4]=176.6+/-41.7 uM) than in the Fly River ([NO3]=1.09+/-0.04 uM, [PO4]=0.01+/-0.01 uM, and [Si(OH)4]=110.6+/-4.8 uM). NO3 and PO4 concentrations in the Fly-Strickland river system were lower than in the Amazon, and silicate was comparable. SS concentrations were higher in the Strickland than in the Fly (49.4-231.1 mg/l vs. 19.5-59.6 mg/l). Coarse particulates were organic-poor in the Fly and Strickland rivers, with <1% organic carbon (OC). Fine particulates contained more OC in the Fly (2.32-9.03%) than in the Strickland (0.99-3.08%). In aggregate, the average OC concentration of Fly-Strickland river SS samples is 3.75+/-3.07%, which is substantially higher than %OC values measured in fine particulates in the Amazon. C/N ratios for fine particulate organic matter (FPOM) are higher in the Fly (13.0-24.1) than in the Strickland (9.5-14.4), suggesting a greater contribution of N-poor, terrestrial organics to the Fly River. FPOM δ 13C values in the Fly are more depleted (-31.1--30.3‰ ) than in the Strickland River (-29.6--28.4‰ ). We intend to estimate the total biogeochemical fluxes associated with these reported concentrations. Collectively, these preliminary data on carbon cycling in the Fly and Strickland rivers suggest that this fluvial dispersal system outgases a substantial volume of CO2 each year relative to its area, much like the Amazon River. However, in contrast to the Amazon, where the majority of the sediment from the Andes is trapped in sub-aerial, intra-cratonal basins, most fluviatile sediment is advected beyond the Fly River mouth. Therefore, due to the higher organic content of the fine suspended sediment in this river system, it seems probable that a relatively greater export and burial flux of organic carbon may occur within the delta and shelf deposits of the Gulf of Papua.
Rahman, M R; Hassan, M R; Faiz, M A; Samad, R; Paul, B; Jalil, M A
1998-12-01
The study was done in a new settler's camp "Barachara" under Sadar thana of Cox's Bazar district. It has a total population of 784 of all age groups, registered in the middle of the study period. A prospective evaluation of all cases of fever were done over 12 months, to see the pattern of febrile illness among the population and to compare the therapeutic efficacy of two alternative drug regimens for uncomplicated falciparum malaria (UM). Blood for malarial parasite (MP) was done in all cases of fever and was treated in line with the new clinical case definitions and treatment guidelines for malaria in Bangladesh. Slide positive UM cases were subjected to a "14-day in-vivo test" for therapeutic efficacy testing of antimalarial agents. The two drug regimens were randomised by lottery--a) 3 days oral chloroquine plus single dose sulphadoxin/pyrimethamine (CQ + SP) and, b) 3 days oral quinine plus single dose sulphadoxin/pyrimethamine (Q3 + SP). Drug administration was supervised by the field assistant and was followed up on days 3, 7 and 14 for blood slide examinations and clinical assessment. Sensitive response was observed in 79% of the cases in the CQ + SP group and 84% in the Q3 + SP group. Early treatment failure (persistently febrile and parasitaemic on days 3 or 7) was observed in 16% in the CQ + SP group and 9% in the Q3 + SP group. Both the evaluated drug regimens had less than 20% failures and can be used as alternative first line agents and Q3 + SP regimens can also be used as the second line agents for treatment failure (to chloroquine and/or SP) UM cases in the study area.
Luscan, A; Just, P A; Briand, A; Burin des Roziers, C; Goussard, P; Nitschké, P; Vidaud, M; Avril, M F; Terris, B; Pasmant, E
2015-04-01
Uveal melanoma (UM) is the most common malignant tumour of the eye. Diagnosis often occurs late in the course of disease, and prognosis is generally poor. Recently, recurrent somatic mutations were described, unravelling additional specific altered pathways in UM. Targeted next-generation sequencing (NGS) can now be applied to an accurate and fast identification of somatic mutations in cancer. The aim of the present study was to characterise the mutation pattern of five UM hepatic metastases with well-defined clinical and pathological features. We analysed the UM mutation spectrum using targeted NGS on 409 cancer genes. Four previous reported genes were found to be recurrently mutated. All tumours presented mutually exclusive GNA11 or GNAQ missense mutations. BAP1 loss-of-function mutations were found in three UMs. SF3B1 missense mutations were found in the two UMs with no BAP1 mutations. We then searched for additional mutation targets. We identified the Arg505Cys mutation in the tumour suppressor FBXW7. The same mutation was previously described in different cancer types, and FBXW7 was recently reported to be mutated in UM exomes. Further studies are required to confirm FBXW7 implication in UM tumorigenesis. Elucidating the molecular mechanisms underlying UM tumorigenesis holds the promise for novel and effective targeted UM therapies. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
NASA Astrophysics Data System (ADS)
Kumari, Seema; Paul, Debajyoti; Stracke, Andreas
2016-12-01
An open system evolutionary model of the Earth, comprising continental crust (CC), upper and lower mantle (UM, LM), and an additional isolated reservoir (IR) has been developed to study the isotopic evolution of the silicate Earth. The model is solved numerically at 1 Myr time steps over 4.55 Gyr of Earth history to reproduce both the present-day concentrations and isotope ratios of key radioactive decay systems (Rb-Sr, Sm-Nd, and U-Th-Pb) in these terrestrial reservoirs. Various crustal growth scenarios - continuous versus episodic and early versus late crustal growth - and their effect on the evolution of Sr-Nd-Pb isotope systematics in the silicate reservoirs have been evaluated. Modeling results where the present-day UM is ∼60% of the total mantle mass and a lower mantle that is non-primitive reproduce the estimated geochemical composition and isotope ratios in Earth's silicate reservoirs. The isotopic evolution of the silicate Earth is strongly affected by the mode of crustal growth; only an exponential crustal growth pattern with crustal growth since the early Archean satisfactorily explains the chemical and isotopic evolution of the crust-mantle system and accounts for the so-called Pb paradoxes. Assuming that the OIB source is located in the deeper mantle, our model could, however, not reproduce its target ɛNd of +4.6 for the UM, which has been estimated from the average isotope ratios of 32 individual ocean island localities. Hence, either mantle plumes sample the LM in a non-representative way, or the simplified model set-up does not capture the full complexity of Earth's lower mantle (Nd isotope) evolution. Compared to the results obtained for a 4.55 Ga Earth, a model assuming a protracted U-Pb evolution of silicate Earth by ca. 100 Myr reproduces a slightly better fit for the Pb isotope ratios in Earth's silicate reservoirs. One notable feature of successful models is the early depletion of incompatible elements (as well as rapid decrease in Th/U) in the UM within the initial 500 Myr, as a result of early formation of CC, which supports other evidence in favor of the presence of Hadean continental crust. Therefore, a chondritic Th/U ratio (4 ± 0.2) in the UM until 2 Gyr appears rather unlikely. We find that the κ conundrum - the observation that measured Th/U ratios and those deduced from 208Pb-206Pb isotope systematics differ - is a natural outcome of an open system evolution in which preferential recycling of U for the past 2 Gyr has played a dominant role. Overall, our simulations strongly favor exponential crustal growth, starting in the early Hadean, the transient preservation of compositionally distinct mantle reservoirs over billion year time periods, and a generally less incompatible element depleted, but non-primitive composition of the lower mantle.
CHARMS: The Cryogenic, High-Accuracy Refraction Measuring System
NASA Technical Reports Server (NTRS)
Frey, Bradley; Leviton, Douglas
2004-01-01
The success of numerous upcoming NASA infrared (IR) missions will rely critically on accurate knowledge of the IR refractive indices of their constituent optical components at design operating temperatures. To satisfy the demand for such data, we have built a Cryogenic, High-Accuracy Refraction Measuring System (CHARMS), which, for typical 1R materials. can measure the index of refraction accurate to (+ or -) 5 x 10sup -3 . This versatile, one-of-a-kind facility can also measure refractive index over a wide range of wavelengths, from 0.105 um in the far-ultraviolet to 6 um in the IR, and over a wide range of temperatures, from 10 K to 100 degrees C, all with comparable accuracies. We first summarize the technical challenges we faced and engineering solutions we developed during the construction of CHARMS. Next we present our "first light," index of refraction data for fused silica and compare our data to previously published results.
Remote Detection of Explosive Molecules by a Microfluidic SERS Device
NASA Astrophysics Data System (ADS)
Piorek, Brian; Lee, Seung Joon; Moskovits, Martin; Banerjee, Sanjoy; Meinhart, Carl
2007-11-01
Free-surface microfluidics (FSF) is combined with surface-enhanced Raman spectroscopy (SERS) to detect trace explosives vapors at room temperature and pressure. A free surface, with a large surface to volume ratio, is created using an open microchannel. Since surface tension is a dominant force at the microscale, it can be used to confine the fluid in the microchannel and create a pressure gradient to drive the flow with velocities ranging from ˜ 1um/s - 1mm/s. The curvature of the free surface is measured by confocal microscopy in order to determine the local Laplace pressure in the free-surface microchannel flow. The system has been used for the molecular-specific detection of vapor emanated from explosives such as DNT, TNT and picric acid. The system does not show signs of performance degradation from common interferents such as saturated gasoline vapor and perfume.
Kim, Jin Young; Carlson, Bradley A.; Xu, Xue-Ming; Zeng, Yu; Chen, Shawn; Gladyshev, Vadim N.; Lee, Byeong Jae; Hatfield, Dolph L.
2011-01-01
There are two isoforms of selenocysteine (Sec) tRNA[Ser]Sec that differ by a single methyl group, Um34. The non-Um34 isoform supports the synthesis of a subclass of selenoproteins, designated housekeeping, while the Um34 isoform supports the expression of another subclass, designated stress-related selenoproteins. Herein, we investigated the relationship between tRNA[Ser]Sec aminoacylation and Um34 synthesis which is the last step in the maturation of this tRNA. Mutation of the discriminator base at position 73 in tRNA[Ser]Sec dramatically reduced aminoacylation with serine, as did an inhibitor of seryl-tRNA synthetase, SB-217452. Although both the mutation and the inhibitor prevented Um34 synthesis, neither precluded the synthesis of any other of the known base modifications on tRNA[Ser]Sec following microinjection and incubation of the mutant tRNA[Ser]Sec transcript, or the wild type transcript along with inhibitor, in Xenopus oocytes. The data demonstrate that Sec tRNA[Ser]Sec must be aminoacylated for Um34 addition. The fact that selenium is required for Um34 methylation suggests that Sec must be attached to its tRNA for Um34 methylation. This would explain why selenium is essential for the function of Um34 methylase and provides further insights into the hierarchy of selenoprotein expression. PMID:21624347
Predictability of short-range forecasting: a multimodel approach
NASA Astrophysics Data System (ADS)
García-Moya, Jose-Antonio; Callado, Alfons; Escribà, Pau; Santos, Carlos; Santos-Muñoz, Daniel; Simarro, Juan
2011-05-01
Numerical weather prediction (NWP) models (including mesoscale) have limitations when it comes to dealing with severe weather events because extreme weather is highly unpredictable, even in the short range. A probabilistic forecast based on an ensemble of slightly different model runs may help to address this issue. Among other ensemble techniques, Multimodel ensemble prediction systems (EPSs) are proving to be useful for adding probabilistic value to mesoscale deterministic models. A Multimodel Short Range Ensemble Prediction System (SREPS) focused on forecasting the weather up to 72 h has been developed at the Spanish Meteorological Service (AEMET). The system uses five different limited area models (LAMs), namely HIRLAM (HIRLAM Consortium), HRM (DWD), the UM (UKMO), MM5 (PSU/NCAR) and COSMO (COSMO Consortium). These models run with initial and boundary conditions provided by five different global deterministic models, namely IFS (ECMWF), UM (UKMO), GME (DWD), GFS (NCEP) and CMC (MSC). AEMET-SREPS (AE) validation on the large-scale flow, using ECMWF analysis, shows a consistent and slightly underdispersive system. For surface parameters, the system shows high skill forecasting binary events. 24-h precipitation probabilistic forecasts are verified using an up-scaling grid of observations from European high-resolution precipitation networks, and compared with ECMWF-EPS (EC).
NASA Astrophysics Data System (ADS)
Terrano, Daniel; Tsuper, Ilona; Maraschky, Adam; Holland, Nolan; Streletzky, Kiril
Temperature sensitive nanoparticles were generated from a construct (H20F) of three chains of elastin-like polypeptides (ELP) linked to a negatively charged foldon domain. This ELP system was mixed at different ratios with linear chains of ELP (H40L) which lacks the foldon domain. The mixed system is soluble at room temperature and at a transition temperature (Tt) will form swollen micelles with the hydrophobic linear chains hidden inside. This system was studied using depolarized dynamic light scattering (DDLS) and static light scattering (SLS) to determine the size, shape, and internal structure of the mixed micelles. The mixed micelle in equal parts of H20F and H40L show a constant apparent hydrodynamic radius of 40-45 nm at the concentration window from 25:25 to 60:60 uM (1:1 ratio). At a fixed 50 uM concentration of the H20F, varying H40L concentration from 5 to 80 uM resulted in a linear growth in the hydrodynamic radius from about 11 to about 62 nm, along with a 1000-fold increase in VH signal. A possible simple model explaining the growth of the swollen micelles is considered. Lastly, the VH signal can indicate elongation in the geometry of the particle or could possibly be a result from anisotropic properties from the core of the micelle. SLS was used to study the molecular weight, and the radius of gyration of the micelle to help identify the structure and morphology of mixed micelles and the tangible cause of the VH signal.
Comparative research on medicine application with 0.53-um, 1.06-um, and 1.32-um Nd:YAG lasers
NASA Astrophysics Data System (ADS)
Li, Yahua; Li, Zhenjia; Zhu, Changhong; Huang, Yizhong
1996-09-01
Because of its high power and excellent optical features, laser has almost been applied to everywhere of medical research and clinic. Over the past several years, laser medical has achieved a rapid progress, and laser medical instruments has developed promptly, each new wavelength can be successfully applied in diagnostic and treatment of diseases. Among the medical lasers, Nd:YAG solid-state laser systems have proven useful in surgical use operate, such as neurosurgery, gastroenterology, cardioangiology, urology, gynecology, dermatology and ENT. As with other solid-state lasers, the Nd:YAG laser can be made to emit various wavelengths by means of suitable resonator configurations and some newest solid-state laser technology, pumped by the Krypton lamp, the Nd:YAG laser at room temperature exhibits transition at 1.06 micrometer Nd:YAG, using nonlinear crystal and Q-switch to double its frequency can attain 0.53 micrometer green beam. In our laser systems, the efficiency at 1.06 micrometer is more than 3 percent, an efficiency of 0.5 percent at 1.32 micrometer and 0.53 micrometer can be attained. For a power of 100w at 1.06 micrometer, 15w at 1.32 micrometer and 0.53 micrometer can therefore be produced. All of three kinds Nd:YAG laser hold these characteristics: high output power; optical fiber transition that can be cooperated with endoscope. The paper mainly discusses laser operating characteristics and clinic applications of three kinds wavelengths at 0.53 micrometer 1.06 micrometer and 1.32 micrometer Nd:YAG laser systems.
Implications of Proposed University of Maryland System Patenting Policy Change.
ERIC Educational Resources Information Center
Clinch, Richard
As a result of actual and anticipated growth in the level of entrepreneurial activities within the University of Maryland System (UMS), and corresponding growth in licensing and royalty revenues, a threshold policy was recommended in the Joint Chairmen's Report of 1996. Such a policy would establish a maximum threshold beyond which a portion of…
Comprehensive Marine Particle Analysis System
2000-09-30
23 00 26 00 29 00 32 00 35 00 38 00 41 00 44 00 47 00 50 00 ESD (microns) N um be r m -3 trichodesm ium Salp and Doliolid pteropod Protist gelatinous...capability of the new sensor system. RESULTS •Data gathered from HRS deployments provided information for HyCODE / ECOHAB models. •Multiple- season optical and
Recent Developments for Satellite-Based Fire Monitoring in Canada
NASA Astrophysics Data System (ADS)
Abuelgasim, A.; Fraser, R.
2002-05-01
Wildfires in Canadian forests are a major source of natural disturbance. These fires have a tremendous impact on the local environment, humans and wildlife, ecosystem function, weather, and climate. Approximately 9000 fires burn 3 million hectares per year in Canada (based on a 10-year average). While only 2 to 3 percent of these wildfires grow larger than 200 hectares in size, they account for almost 97 percent of the annual area burned. This provides an excellent opportunity to monitor active fires using a combination of low and high resolution sensors for the purpose of determining fire location and burned areas. Given the size of Canada, the use of remote sensing data is a cost-effective way to achieve a synoptic overview of large forest fire activity in near-real time. In 1998 the Canada Centre for Remote Sensing (CCRS) and the Canadian Forest Service (CFS) developed a system for Fire Monitoring, Mapping and Modelling (Fire M3;http://fms.nofc.cfs.nrcan.gc.ca/FireM3/). Fire M3 automatically identifies, monitors, and maps large forest fires on a daily basis using NOAA AVHRR data. These data are processed daily using the GEOCOMP-N satellite image processing system. This presentation will describe recent developments to Fire M3, included the addition of a set of algorithms tailored for NOAA-16 (N-16) data. The two fire detection algorithms are developed for N-16 day and night-time daily data collection. The algorithms exploit both the multi-spectral and thermal information from the AVHRR daily images. The set of N-16 day and night algorithms was used to generate daily active fire maps across North America for the 2001 fire season. Such a combined approach for fire detection leads to an improved detection rate, although day-time detection based on the new 1.6 um channel was much less effective (note - given the low detection rate with day time imagery, I don't think we can make the statement about capturing the diurnal cycle). Selected validation sites in western Canada and the United States showed reasonable correspondence with the location of fires mapped by CFS and those mapped by the USDA Forest Service using conventional means.
Reid, Paul; Wilson, Puthenparampil; Li, Yanrui; Marcu, Loredana G; Staudacher, Alexander H; Brown, Michael P; Bezak, Eva
2017-01-01
Some head and neck squamous cell carcinomas (HNSCC) have a distinct aetiology, which depends on the presence of oncogenic human papilloma virus (HPV). Also, HNSCC contains cancer stem cells (CSCs) that have greater radioresistance and capacity to change replication dynamics in response to irradiation compared to non-clonogenic cells. Since there is limited data on CSCs in HNSCC as a function of HPV status, better understanding of their radiobiology may enable improved treatment outcome. Baseline and post-irradiation changes in CSC proportions were investigated by flow cytometry in a HPV-negative (UM-SCC-1) and a HPV-positive (UM-SCC-47) HNSCC cell line, using fluorescent staining with CD44/ALDH markers. CSC proportions in both irradiated and unirradiated cultures were compared for the two cell lines at various times post-irradiation. To assess repopulation of CSCs, untreated cultures were depleted of CD44+/ALDH+ cells and re-cultured for 3 weeks before flow cytometry analysis. CSC proportions in untreated cell lines were 0.57% (UM-SCC-1) and 2.87% (UM-SCC-47). Untreated cell lines depleted of CD44+/ALDH+ repopulated this phenotype to a mean of 0.15% (UM-SCC-1) and 6.76% (UM-SCC-47). All UM-SCC-47 generations showed elevated CSC proportions after irradiation, with the most significant increase at 2 days post-irradiation. The highest elevation in UM-SCC-1 CSCs was observed at 1 day post-irradiation in the 2nd generation and at 3 days after irradiation in the 3rd generation. When measured after 10 days, only the 3rd generation of UM-SCC-1 showed elevated CSCs. CSC proportions in both cell lines were elevated after exposure and varied with time post irradiation. UM-SCC-47 displayed significant plasticity in repopulating the CSC phenotype in depleted cultures, which was not seen in UM-SCC-1.
Study of factors affecting growth and cold acclimation of Vitis callus cultures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deng, L.
1987-01-01
In vitro grape tissue culture initiation, growth, and cold acclimation were studied. Factors involved were genotypes, media, plant growth regulators, age, light, temperature, antioxidant, clearing and adsorbing agents, sucrose level, osmotic potential, ABA, chilling and freezing treatments. Murashige and Skoog (MS) medium containing 1 ..mu..M 2,4-d + 0.1 uM Ba, MS containing 1 uM 2,4-D, and woody plant medium containing 1 uM 2,4-D + 0.1 uM BA produced abundant callus tissue for most grape genotypes; either WPM or MS containing 1 uM BA stimulated shoot growth in all the 12 genotypes tested. Adding 1 uM abscisic acid (ABA) to themore » B5 medium with 1 uM 2,4-D and 0.5 uM BA enhanced growth and quality of Chancellor callus. /sup 3/H-ABA was taken up actively by callus tissue at 12 days after subculture, but by 20 d this effect disappeared. When /sup 14/C-sucrose was added to the medium. /sup 14/C level of cells reached a plateau after 48 h; this plateau was higher if ABA was also present in the medium. Cells on media containing ABA were larger in size, lighter in color, and more loosely connected.« less
NASA Astrophysics Data System (ADS)
Rahayuningsih, Titi; Pranoto, Nindyawati, Umniati, B. Sri; Mardhika, Moch Aqfa Syabahid
2017-09-01
Universitas Negeri Malang (UM) is a university with the second largest academic community in Malang. The activities of the academic community should be supported by adequate facilities, such as pedestrian facilities—crucial yet much neglected matters, so pedestrians to walk along the roadway. As a result, conflicts between pedestrians with motor vehicle users and accidents might occur at any time. This research aimed at: 1) investigating the geometric conditions of pedestrian facilities at UM; 2) identifying the characteristics of pedestrians and the pedestrian facilities at UM; and 3) determining the level of service for pedestrian facilities at UM using Geographic Information System (GIS). The research was conducted through survey of location, survey of geometric conditions, estimation of the number of pedestrians using sidewalk (data were recorded every 15 minutes), measurement of pedestrian speed, and questionnaire about pedestrians' identity, destination, as well as travel time and distance. Data analysis was carried out to identify the pedestrian characteristics, pedestrian flow characteristics, and pedestrian level of service. The research result showed that the percentage of road segments in campus without sidewalks was 52%. The average width of sidewalk was 1.33 m, which was less than the minimum standard of i.e. 2 m. In terms of pedestrian characteristics, the pedestrians consisted of more female (51%) who were mostly students of the Faculty of Letters whose destination was classroom building. The maximum pedestrian flow was at 10.00-13.30 i.e. 4.2018 p/m/min. The average speed of pedestrian was 63.49 m/min. The highest pedestrian density of 0.0609 p/m2 occurred at 10.00-13.30. The largest walking space was 28.0348 m2/p and occurred in the afternoon at 13.30-17.00. The level of service for pedestrian facilities belonged to category A in the morning and afternoon. The level of service at 10.00-13.30 decreased to category B.
Three-frequency Nd:YAG laser for dental treatment
NASA Astrophysics Data System (ADS)
Kadlecová, Martina; Dostálová, Tat'jana; Jelínková, Helena; Němec, Michal; Å ulc, Jan; Fibrich, Martin; Bradna, Pavel; Nejezchleb, Karel; Kapitch, Nickalai; Å koda, Václav
2018-02-01
In the last decade, lasers found a number of indications in dentistry. However, there is still one problem: the narrow spectrum of usefulness for individual radiation wavelengths. The aim of our study is to demonstrate the use of a compact three-frequency pulsed Nd-YAG laser for more than one treatment, namely disinfection, coagulation, selective ablation, and soft tissue removal. The laser wavelengths and the maximal energies achieved were the following: 1.06 um, 1.32 um, 1.44 um and 830 mJ, 425 mJ, and 200 mJ, respectively. It has been found that all of the investigated wavelengths exhibit disinfection properties. Moreover, radiation of 1.06 um wavelength removes soft tissue and exhibits also coagulation properties. Radiation of 1.44 um is most useful for selective ablation of initial caries and disinfection, and 1.32 um radiation can be used for precise ablation when higher energy is applied.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fong, Theodore E.
2013-05-06
The technical paper summarizes the project work conducted in the development of Kerf-Free silicon wafering equipment for silicon solar wafering. This new PolyMax technology uses a two step process of implantation and cleaving to exfoliate 50um to 120um wafers with thicknesses ranging from 50um to 120um from a 125mm or 156mm pseudo-squared silicon ingot. No kerf is generated using this method of wafering. This method of wafering contrasts with the current method of making silicon solar wafers using the industry standard wire saw equipment. The report summarizes the activity conducted by Silicon Genesis Corporation in working to develop this technologymore » further and to define the roadmap specifications for the first commercial proto-type equipment for high volume solar wafer manufacturing using the PolyMax technology.« less
NASA Technical Reports Server (NTRS)
1991-01-01
Project UM-Haul is the preliminary design of a reusable lunar transportation vehicle that travels between a lunar parking orbit and the lunar surface. This vehicle is an indispensible link in the overall task of establishing a lunar base as defined by the NASA Space Exploration Initiative. The response to this need consists of two independent vehicles: a lander and an unloader. The system can navigate and unload itself with a minimum amount of human intervention. The design addresses structural analysis, propulsion, power, controls, communications, payload handling and orbital operations. The Lander has the capacity to decend from low lunar orbit (LLO) to the lunar surface carrying a 7000 kg payload, plus the unloader, plus propellant for ascent to LLO. The Lander employs the Unloader by way of a motorized ramp. The Unloader is a terrain vehicle capable of carrying cargoes of 8,500 kg mass and employs a lift system to lower payloads to the ground. The system can perform ten missions before requiring major servicing.
Shuttle Flight Experiment on USMP-4: In Situ Monitoring of Crystal Growth Using MEPHISTO
NASA Technical Reports Server (NTRS)
Abbaschian, Reza; deGroh, Henry C., III; Leonardi, E.; deVahlDavis, Graham; Coriell, Sam; Cambon, Gerard
2001-01-01
This reports on the MEPHISTO-4 experiment on the Space Shuttle Columbia, STS-87, November 19-December 5, 1997. Involved were NASA; the University of Florida at Gainesville; groups from France that developed and built the furnace; the National Institute of Standards and Technology; The University of New South Wales, Australia; and Purdue University. This was a solidification study in which three long rods of Bismuth- 1 at.% Tin were directionally solidified. The goals were to solidify in an environment free of natural convection; to determine the relationship among solidification growth velocity, growth mode, and temperature; and determine the diffusivity of Sn in Bi. The flight samples grew with a planar solid/liquid interface at velocities less than 3.4 gm/s, and cellular growth was present at velocities greater than 6.7 um/s; grain orientation influenced the planar to cellular transition. The temperature gradient in the liquid was 204 K/cm. The s/l interface was flat with slight concavity. Diffusion-dominated conditions were present during MEPHISTO-4. The Seebeck technique was used to determine the s/I interface temperature during growth, however, to date, analysis of the Seebeck results has not yielded a reliable measurement of the interface temperature. The partition coefficient for Bi alloyed with Sn was measured, k = 0.029.
Compositional control of continuously graded anode functional layer
NASA Astrophysics Data System (ADS)
McCoppin, J.; Barney, I.; Mukhopadhyay, S.; Miller, R.; Reitz, T.; Young, D.
2012-10-01
In this work, solid oxide fuel cells (SOFC's) are fabricated with linear-compositionally graded anode functional layers (CGAFL) using a computer-controlled compound aerosol deposition (CCAD) system. Cells with different CGAFL thicknesses (30 um and 50 um) are prepared with a continuous compositionally graded interface deposited between the electrolyte and anode support current collecting regions. The compositional profile was characterized using energy dispersive X-ray spectroscopic mapping. An analytical model of the compound aerosol deposition was developed. The model predicted compositional profiles for both samples that closely matched the measured profiles, suggesting that aerosol-based deposition methods are capable of creating functional gradation on length scales suitable for solid oxide fuel cell structures. The electrochemical performances of the two cells are analyzed using electrochemical impedance spectroscopy (EIS).
Hübner, Uwe; von Gunten, Urs; Jekel, Martin
2015-01-01
Ozonation is an efficient treatment system to reduce the concentration of trace organic compounds (TrOCs) from technical aquatic systems such as drinking water, wastewater and industrial water, etc. Although it is well established that ozonation generally improves the removal of organic matter in biological post-treatment, little is known about the biodegradability of individual transformation products resulting from ozonation of TrOCs. This publication provides a qualified assessment of the persistence of ozone-induced transformation products based on a review of published product studies and an evaluation of the biodegradability of transformation products with the biodegradability probability program (BIOWIN) and the University of Minnesota Pathway Prediction System (UM-PPS). The oxidation of TrOCs containing the four major ozone-reactive sites (olefins, amines, aromatics and sulfur-containing compounds) follows well described reaction pathways leading to characteristic transformation products. Assessment of biodegradability revealed a high sensitivity to the formed products and hence the ozone-reactive site present in the target compound. Based on BIOWIN, efficient removal can be expected for products from cleavage of olefin groups and aromatic rings. In contrast, estimations and literature indicate that hydroxylamines and N-oxides, the major products from ozonation of secondary and tertiary amines are not necessarily better removed in biological post-treatment. According to UM-PPS, degradation of these products might even occur via reformation of the corresponding amine. Some product studies with sulfide-containing TrOCs showed a stoichiometric formation of sulfoxides from oxygen transfer reactions. However, conclusions on the fate of transformation products in biological post-treatment cannot be drawn based on BIOWIN and UM-PPS.
Interstellar and Solar System Organic Matter Preserved in Interplanetary Dust
NASA Technical Reports Server (NTRS)
Messenger, Scott; Nakamura-Messenger, Keiko
2015-01-01
Interplanetary dust particles (IDPs) collected in the Earth's stratosphere derive from collisions among asteroids and by the disruption and outgassing of short-period comets. Chondritic porous (CP) IDPs are among the most primitive Solar System materials. CP-IDPs have been linked to cometary parent bodies by their mineralogy, textures, C-content, and dynamical histories. CP-IDPs are fragile, fine-grained (less than um) assemblages of anhydrous amorphous and crystalline silicates, oxides and sulfides bound together by abundant carbonaceous material. Ancient silicate, oxide, and SiC stardust grains exhibiting highly anomalous isotopic compositions are abundant in CP-IDPs, constituting 0.01 - 1 % of the mass of the particles. The organic matter in CP-IDPs is isotopically anomalous, with enrichments in D/H reaching 50x the terrestrial SMOW value and 15N/14N ratios up to 3x terrestrial standard compositions. These anomalies are indicative of low T (10-100 K) mass fractionation in cold molecular cloud or the outermost reaches of the protosolar disk. The organic matter shows distinct morphologies, including sub-um globules, bubbly textures, featureless, and with mineral inclusions. Infrared spectroscopy and mass spectrometry studies of organic matter in IDPs reveals diverse species including aliphatic and aromatic compounds. The organic matter with the highest isotopic anomalies appears to be richer in aliphatic compounds. These materials also bear similarities and differences with primitive, isotopically anomalous organic matter in carbonaceous chondrite meteorites. The diversity of the organic chemistry, morphology, and isotopic properties in IDPs and meteorites reflects variable preservation of interstellar/primordial components and Solar System processing. One unifying feature is the presence of sub-um isotopically anomalous organic globules among all primitive materials, including IDPs, meteorites, and comet Wild-2 samples returned by the Stardust mission.
NASA Astrophysics Data System (ADS)
Guo, Yanhui; Zhou, Chuan; Chan, Heang-Ping; Wei, Jun; Chughtai, Aamer; Sundaram, Baskaran; Hadjiiski, Lubomir M.; Patel, Smita; Kazerooni, Ella A.
2013-04-01
A 3D multiscale intensity homogeneity transformation (MIHT) method was developed to reduce false positives (FPs) in our previously developed CAD system for pulmonary embolism (PE) detection. In MIHT, the voxel intensity of a PE candidate region was transformed to an intensity homogeneity value (IHV) with respect to the local median intensity. The IHVs were calculated in multiscales (MIHVs) to measure the intensity homogeneity, taking into account vessels of different sizes and different degrees of occlusion. Seven new features including the entropy, gradient, and moments that characterized the intensity distributions of the candidate regions were derived from the MIHVs and combined with the previously designed features that described the shape and intensity of PE candidates for the training of a linear classifier to reduce the FPs. 59 CTPA PE cases were collected from our patient files (UM set) with IRB approval and 69 cases from the PIOPED II data set with access permission. 595 and 800 PEs were identified as reference standard by experienced thoracic radiologists in the UM and PIOPED set, respectively. FROC analysis was used for performance evaluation. Compared with our previous CAD system, at a test sensitivity of 80%, the new method reduced the FP rate from 18.9 to 14.1/scan for the PIOPED set when the classifier was trained with the UM set and from 22.6 to 16.0/scan vice versa. The improvement was statistically significant (p<0.05) by JAFROC analysis. This study demonstrated that the MIHT method is effective in reducing FPs and improving the performance of the CAD system.
Detecting metal-poor gas accretion in the star-forming dwarf galaxies UM 461 and Mrk 600
NASA Astrophysics Data System (ADS)
Lagos, P.; Scott, T. C.; Nigoche-Netro, A.; Demarco, R.; Humphrey, A.; Papaderos, P.
2018-06-01
Using VIsible MultiObject Spectrograph (VIMOS)-integral field unit (IFU) observations, we study the interstellar medium (ISM) of two star-forming dwarf galaxies, UM 461 and Mrk 600. Our aim was to search for the existence of metallicity inhomogeneities that might arise from infall of nearly pristine gas feeding ongoing localized star formation. The IFU data allowed us to study the impact of external gas accretion on the chemical evolution as well as the ionized gas kinematics and morphologies of these galaxies. Both systems show signs of morphological distortions, including cometary-like morphologies. We analysed the spatial variation of 12 + log(O/H) abundances within both galaxies using the direct method (Te), the widely applied HII-CHI-mistry code, as well as by employing different standard calibrations. For UM 461, our results show that the ISM is fairly well mixed, at large scales; however, we find an off-centre and low-metallicity region with 12 + log(O/H) < 7.6 in the SW part of the brightest H II region, using the direct method. This result is consistent with the recent infall of a metal-poor H I cloud into the region now exhibiting the lowest metallicity, which also displays localized perturbed neutral and ionized gas kinematics. Mrk 600 in contrast, appears to be chemically homogeneous on both large and small scales. The intrinsic differences in the spatially resolved properties of the ISM in our analysed galaxies are consistent with these systems being at different evolutionary stages.
NASA Astrophysics Data System (ADS)
Qi, Yadong; Bai, Shuju; Vogelmann, Thomas C.; Heisler, Gordon M.
2003-11-01
The depth of light penetration from the adaxial surfaces of the mature leaves of pecan (Carya illinoensis) was measured using a fiber optic microprobe system at four wavelengths: UV-B (310nm), UV-A (360 nm), blue light (430nm), and red light (680nm). The average thickness of the leaf adaxial epidermal layer was 15um and the total leaf thickness was 219um. The patterns of the light attenuation by the leaf tissues exhibited strong wavelength dependence. The leaf adaxial epidermal layer was chiefly responsible for absorbing the UV-A UV-B radiation. About 98% of 310 nm light was steeply attenuated within the first 5 um of the adaxial epidermis; thus, very little UV-B radiation was transmitted to the mesophyll tissues where contain photosynthetically sensitive sites. The adaxial epidermis also attenuated 96% of the UV-A radiation. In contrast, the blue and red light penetrated much deeper and was gradually attenutated by the leaves. The mesophyll tissues attenuated 17% of the blue light and 42% of the red light, which were available for photosynthesis use. Since the epidermal layer absorbed nearly all UV-B light, it acted as an effective filter screening out the harmful radiation and protecting photosynthetically sensitive tissues from the UV-B damage. Therefore, the epidermal function of the UV-B screening effectiveness can be regarded as one of the UV-B protection mechanisms in pecan.
NASA Astrophysics Data System (ADS)
Noh, Young-Chan; Sohn, Byung-Ju; Kim, Yoonjae; Joo, Sangwon; Bell, William; Saunders, Roger
2017-11-01
A new set of Infrared Atmospheric Sounding Interferometer (IASI) channels was re-selected from 314 EUMETSAT channels. In selecting channels, we calculated the impact of the individually added channel on the improvement in the analysis outputs from a one-dimensional variational analysis (1D-Var) for the Unified Model (UM) data assimilation system at the Met Office, using the channel score index (CSI) as a figure of merit. Then, 200 channels were selected in order by counting each individual channel's CSI contribution. Compared with the operationally used 183 channels for the UM at the Met Office, the new set shares 149 channels, while the other 51 channels are new. Also examined is the selection from the entropy reduction method with the same 1D-Var approach. Results suggest that channel selection can be made in a more objective fashion using the proposed CSI method. This is because the most important channels can be selected across the whole IASI observation spectrum. In the experimental trial runs using the UM global assimilation system, the new channels had an overall neutral impact in terms of improvement in forecasts, as compared with results from the operational channels. However, upper-tropospheric moist biases shown in the control run with operational channels were significantly reduced in the experimental trial with the newly selected channels. The reduction of moist biases was mainly due to the additional water vapor channels, which are sensitive to the upper-tropospheric water vapor.
Histone deacetylase inhibitors induce growth arrest and differentiation in uveal melanoma
Landreville, Solange; Agapova, Olga A.; Matatall, Katie A.; Kneass, Zachary T.; Onken, Michael D.; Lee, Ryan S.; Bowcock, Anne M.; Harbour, J. William
2011-01-01
Purpose Metastasis is responsible for the death of most cancer patients, yet few therapeutic agents are available which specifically target the molecular events that lead to metastasis. We recently showed that inactivating mutations in the tumor suppressor gene BAP1 are closely associated with loss of melanocytic differentiation in uveal melanoma and metastasis (UM). The purpose of this study was to identify therapeutic agents that reverse the phenotypic effects of BAP1 loss in UM. Experimental Design In silico screens were performed to identify therapeutic compounds predicted to differentiate UM cells using Gene Set Enrichment Analysis and Connectivity Map databases. Valproic acid, trichostatin A, LBH-589 and suberoylanilide hydroxamic acid were evaluated for their effects on UM cells using morphologic evaluation, MTS viability assays, BrdU incorporation, flow cytometry, clonogenic assays, gene expression profiling, histone acetylation and ubiquitination assays, and a murine xenograft tumorigenicity model. Results HDAC inhibitors induced morphologic differentiation, cell cycle exit, and a shift to a differentiated, melanocytic gene expression profile in cultured UM cells. Valproic acid inhibited the growth of UM tumors in vivo. Conclusions These findings suggest that HDAC inhibitors may have therapeutic potential for inducing differentiation and prolonged dormancy of micrometastatic disease in UM. PMID:22038994
Levels of Autonomy and Autonomous System Performance Assessment for Intelligent Unmanned Systems
2014-04-01
LIDAR and camera sensors that is driven entirely by teleoperation would be AL 0. If that same robot used its LIDAR and camera data to generate a...obstacle detection, mapping, path planning 3 CMMAD semi- autonomous counter- mine system (Few 2010) Talon UGV, camera, LIDAR , metal detector...NCAP framework are performed on individual UMS components and do not require mission level evaluations. For example, bench testing of camera, LIDAR
NASA Astrophysics Data System (ADS)
Kaenders, Rainer; Kvasz, Ladislav
Wenn jemand sagt, dass ein Bus um 9 Uhr abfährt - weiß man es dann? Angenommen, man ist darüber unterrichtet, dass die Busse unter der Woche immer zur vollen Stunde abfahren - von 7 Uhr morgens bis 7 Uhr abends, weiß man es dann mit dem Wissen um diese allgemeine Regel besser, dass der Bus um 9 Uhr abfährt? Macht es einen Unterschied, ob man den Fahrplan erstellt, den Bus lenkt oder nur mitfährt, um sich dieser Tatsache bewusst zu sein?
VizieR Online Data Catalog: YSOs in California Molecular Cloud (Lada+, 2017)
NASA Astrophysics Data System (ADS)
Lada, C. J.; Lewis, J. A.; Lombardi, M.; Alves, J.
2018-01-01
The CMC was observed by the all-sky Planck observatory and by the Herschel Space Observatory as part of the "Auriga-California" program (Harvey et al. 2013, Cat J/ApJ/764/133). The Herschel data we used consisted of observations obtained in parallel mode simultaneously using the PACS and SPIRE instruments. For the purposes of this study we use Herschel observations made in the PACS 160um band, and the SPIRE 250um, 350um and 500um bands. (1 data file).
NASA Astrophysics Data System (ADS)
Imaki, Masaharu; Kojima, Ryota; Kameyama, Shumpei
2018-04-01
We have studied a ground based coherent differential absorption LIDAR (DIAL) for vertical profiling of water vapor density using a 1.5μm laser wavelength. A coherent LIDAR has an advantage in daytime measurement compared with incoherent LIDAR because the influence of background light is greatly suppressed. In addition, the LIDAR can simultaneously measure wind speed and water vapor density. We had developed a wavelength locking circuit using the phase modulation technique and offset locking technique, and wavelength stabilities of 0.123 pm which corresponds to 16 MHz are realized. In this paper, we report the wavelength locking circuits for the 1.5 um wavelength.
1985-09-04
health effects was noted in any of the monitor wells. Wells RFW- I , RFW-2A, . and RFW-4, at the Base Landfill, RFW-5 (CFTA) and RFW-10 (PFSA) were...88-D-4006 F/G 24/4 UmEohEEEEEEmiE EEEEEAhEEEEEEEEEEEEEEEEEE EhEEEEmmhmmhhEEE I EEEEEEEEEEEEE 11111 3315 111W12 w ~ ~ ~ ~ d -W w w - v w v w ,!:..4 4...OEHL) Brooks Air Force Ba:;e, Texas 78235-5501• DTIC ECTE October 1935 JUL 0 6 1988 H p.’ DESI CONSULTANTS Approve-. h)r pvhTElMre Volume I - Text " L
Media processors using a new microsystem architecture designed for the Internet era
NASA Astrophysics Data System (ADS)
Wyland, David C.
1999-12-01
The demands of digital image processing, communications and multimedia applications are growing more rapidly than traditional design methods can fulfill them. Previously, only custom hardware designs could provide the performance required to meet the demands of these applications. However, hardware design has reached a crisis point. Hardware design can no longer deliver a product with the required performance and cost in a reasonable time for a reasonable risk. Software based designs running on conventional processors can deliver working designs in a reasonable time and with low risk but cannot meet the performance requirements. What is needed is a media processing approach that combines very high performance, a simple programming model, complete programmability, short time to market and scalability. The Universal Micro System (UMS) is a solution to these problems. The UMS is a completely programmable (including I/O) system on a chip that combines hardware performance with the fast time to market, low cost and low risk of software designs.
An ethical leadership program for nursing unit managers.
Jeon, Sang Hee; Park, Mihyun; Choi, Kyungok; Kim, Mi Kyoung
2018-03-01
The aims of this study were to evaluate the effect of an ethical leadership program (ELP) on ethical leadership, organizational citizenship behavior (OCB), and job outcomes of nursing unit managers (UMs) and to examine changes in staff nurses' perception about UMs' EL, OCB, job outcomes, and ethical work environments (EWEs) post-ELP. A quasi-experimental (pre- and post-test design) study conducted six-month intervention (ELP) using self-reported UM survey (n=44), and staff nurses (n=158) were randomly extracted by two steps. The Korean version of Ethical Leadership at Work for UMs' self-ethical leadership, the Ethical Leadership Scale for staff nurses' perceived ethical leadership, a 19-item OCB scale, and six dimensions of the medium-sized Copenhagen Psychosocial Questionnaire II for job outcomes and EWEs were administered at baseline and post-intervention. UMs' ethical leadership scores differed significantly over time in people orientation (p=0.041) and concern for ethical leadership sustainability (p=0.002) adjusting for UM experience duration and nursing unit type. Total mean and level of power-sharing of ethical leadership among UMs with <5years of UM experience improved significantly over time. Of staff nurses' perception changes about UMs' ethical leadership, OCB, job outcomes, and EWEs, significant improvement over time appeared only in EWEs' work influence level (p=0.007). This study provides useful information for clinical ELP development and examining the program's effect on leadership skills and followers' outcomes. Program facilitation relies on practical training methods, participant motivation, and assessment outcome designs by controlling clinical confounding factors. Findings have implications as an attempt for intervention to promote competencies related to ethical leadership of nursing unit managers. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Mainzer, Amy K.; NEOCam Science Team
2017-10-01
The Near-Earth Object Camera (NEOCam) is a NASA mission in formulation designed to find, track, and provide basic physical characterization of asteroids and comets that make close approaches to Earth. Its goal is to reduce the risk of impacts from undetected near-Earth objects (NEOs) capable of causing global and regional disasters. NEOCam consists of a 50 cm telescope operating at two channels dominated by NEO thermal emission, 4.2-5.0um and 6-10um, in order to better constrain the objects' temperatures and diameters. Orbiting the Sun-Earth L1 Lagrange point, the mission would find hundreds of thousands of NEOs and would make significant progress toward the Congressional objective of discovering more than 90% of NEOs larger than 140 m during its five-year lifetime. The mission uses novel 2048x2048 HgCdTe detectors that extend the wavelength cutoff beyond 10um at an operating temperature of 40K (Dorn et al. 2016). Both the optical system and the detectors are cooled passively using radiators and thermal shields to enable long mission life and to avoid the complexity of cryocoolers or cryogens. NEOCam is currently in an extended Phase A.
Novel method of finding extreme edges in a convex set of N-dimension vectors
NASA Astrophysics Data System (ADS)
Hu, Chia-Lun J.
2001-11-01
As we published in the last few years, for a binary neural network pattern recognition system to learn a given mapping {Um mapped to Vm, m=1 to M} where um is an N- dimension analog (pattern) vector, Vm is a P-bit binary (classification) vector, the if-and-only-if (IFF) condition that this network can learn this mapping is that each i-set in {Ymi, m=1 to M} (where Ymithere existsVmiUm and Vmi=+1 or -1, is the i-th bit of VR-m).)(i=1 to P and there are P sets included here.) Is POSITIVELY, LINEARLY, INDEPENDENT or PLI. We have shown that this PLI condition is MORE GENERAL than the convexity condition applied to a set of N-vectors. In the design of old learning machines, we know that if a set of N-dimension analog vectors form a convex set, and if the machine can learn the boundary vectors (or extreme edges) of this set, then it can definitely learn the inside vectors contained in this POLYHEDRON CONE. This paper reports a new method and new algorithm to find the boundary vectors of a convex set of ND analog vectors.
NASA Astrophysics Data System (ADS)
Albert, Felicie; Pak, A.; Kerr, S.; Lemos, N.; Link, A.; Patel, P.; Pollock, B. B.; Haberberger, D.; Froula, D.; Gauthier, M.; Glenzer, S. H.; Longman, A.; Manzoor, L.; Fedosejevs, R.; Tochitsky, S.; Joshi, C.; Fiuza, F.
2017-10-01
In this work, we report on electrostatic collisionless shock wave acceleration experiments that produced proton beams with peak energies between 10-17.5 MeV, with narrow energy spreads between Δ E / E of 10-20%, and with a total number of protons in these peaks of 1e7-1e8. These beams of ions were created by driving an electrostatic collisionless shock wave in a tailored near critical density plasma target using the ultra-intense ps duration Titan laser that operates at a wavelength of 1 um. The near critical density target was produced through the ablation of an initially 0.5 um thick Mylar foil with a separate low intensity laser. A narrow energy spread distribution of carbon / oxygen ions with a similar velocity to the accelerated proton distribution, consistent with the reflection and acceleration of ions from an electrostatic field, was also observed. This work was supported by Lawrence Livermore National Laboratory's Laboratory Directed Research and Development program under project 15-LW-095, and the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA2734.
Double Fourier Series Solution of Poisson’s Equation on a Sphere.
1980-10-29
algebraic systems, the solution of these systems, and the inverse transform of the solution in Fourier space back to physi- cal space. 6. Yee, S. Y. K...Multiply each count in steps (2) through (5) by K] 7. Inverse transform um(0j j = 1, J - 1, to obtain u k; set u(P) = u 0 (P). [K(J - 1) log 2 K
Unique Spectroscopy and Imaging of Terrestrial Planets with JWST
NASA Astrophysics Data System (ADS)
Villanueva, Geronimo Luis; JWST Mars Team
2017-06-01
In this talk, I will present the main capabilities of the James Webb Space Telescope (JWST) for performing observations of terrestrial planets, using Mars as a test case. The distinctive vantage point of JWST at the Sun-Earth Lagrange point (L2) will allow sampling the full observable disk, permitting the study of short-term phenomena, diurnal processes (across the East-West axis) and latitudinal processes between the hemispheres (including seasonal effects) with excellent spatial resolutions (0.07 arcsec at 2 um). Spectroscopic observations will be achievable in the 0.7-5 um spectral region with NIRSpec at a maximum resolving power of 2700, and with 8000 in the 1-1.25 um range. Imaging will be attainable with NIRCam at 4.3 um and with two narrow filters near 2 um, while the nightside will be accessible with several filters in the 0.5 to 2 um. Such a powerful suite of instruments will be a major asset for the exploration and characterization of Mars, and terrestrial planets in general. Some science cases include the mapping of the water D/H ratio, investigations of the Martian mesosphere via the characterization of the non-LTE CO2 emission at 4.3 um, studies of chemical transport via observations of the O2 nightglow at 1.27 um, high cadence mapping of the variability dust and water ice clouds, and sensitive searches for trace species and hydrated features on the planetary surface.
Development and External Validation of a Prognostic Nomogram for Metastatic Uveal Melanoma
Valpione, Sara; Moser, Justin C.; Parrozzani, Raffaele; Bazzi, Marco; Mansfield, Aaron S.; Mocellin, Simone; Pigozzo, Jacopo; Midena, Edoardo; Markovic, Svetomir N.; Aliberti, Camillo; Campana, Luca G.; Chiarion-Sileni, Vanna
2015-01-01
Background Approximately 50% of patients with uveal melanoma (UM) will develop metastatic disease, usually involving the liver. The outcome of metastatic UM (mUM) is generally poor and no standard therapy has been established. Additionally, clinicians lack a validated prognostic tool to evaluate these patients. The aim of this work was to develop a reliable prognostic nomogram for clinicians. Patients and Methods Two cohorts of mUM patients, from Veneto Oncology Institute (IOV) (N=152) and Mayo Clinic (MC) (N=102), were analyzed to develop and externally validate, a prognostic nomogram. Results The median survival of mUM was 17.2 months in the IOV cohort and 19.7 in the MC cohort. Percentage of liver involvement (HR 1.6), elevated levels of serum LDH (HR 1.6), and a WHO performance status=1 (HR 1.5) or 2–3 (HR 4.6) were associated with worse prognosis. Longer disease-free interval from diagnosis of UM to that of mUM conferred a survival advantage (HR 0.9). The nomogram had a concordance probability of 0.75 (SE .006) in the development dataset (IOV), and 0.80 (SE .009) in the external validation (MC). Nomogram predictions were well calibrated. Conclusions The nomogram, which includes percentage of liver involvement, LDH levels, WHO performance status and disease free-interval accurately predicts the prognosis of mUM and could be useful for decision-making and risk stratification for clinical trials. PMID:25780931
VizieR Online Data Catalog: A dust model for bet Pic from 0.58 to 870um (Ballering+, 2016)
NASA Astrophysics Data System (ADS)
Ballering, N. P.; Su, K. Y. L.; Rieke, G. H.; Gaspar, A.
2016-08-01
β Pic was imaged with the HST/STIS CCD in coronagraphic (50CORON) mode under program GO-12551 (PI: Apai), and the results of these observations were published in Apai et al. (2015ApJ...800..136A). The instrument bandpass is set by the response of the CCD and centered at 0.58um. We searched the HST archive and found previously unpublished observations of β Pic with the WFC3 instrument in the IR channel (filter F110W at ~1.16um) from program GO-11150 (PI: Graham). The Spitzer/MIPS observations of β Pic were taken under the Spitzer Guaranteed Time Observing Program 90 (PI: M. Werner). The data at all three bands (24, 70, and 160um) are published here for the first time. Two sets of 24um observations were obtained. The first set was obtained on 2004 March 20, the second set of data was obtained on 2004 April 11. Two sets of 70um observations were obtained. The first set was obtained on 2004 April 12. The second set was obtained on 2005 April 4. Herschel/PACS 70um scan map observations of β Pic (PI G. Olofsson, observation IDs 1342186612 and 1342186613) were published by Vandenbussche et al. (2010A&A...518L.133V). We used the ALMA 870um continuum image previously published by Dent et al. (2014Sci...343.1490D). (1 data file).
Xiong, Qiulin; Zhao, Wenji; Gong, Zhaoning; Zhao, Wenhui; Tang, Tao
2015-09-22
Fine particulate matter has become the premier air pollutant of Beijing in recent years, enormously impacting the environmental quality of the city and the health of the residents. Fine particles with aerodynamic diameters of 0~0.3 μm, 0.3~0.5 μm, and 0.5~1.0 μm, from the yeasr 2007 to 2012, were monitored, and the hospital data about respiratory diseases during the same period was gathered and calculated. Then the correlation between respiratory health and fine particles was studied by spatial analysis and grey correlation analysis. The results showed that the aerial fine particulate matter pollution was mainly distributed in the Zizhuyuan sub-district office. There was a certain association between respiratory health and fine particles. Outpatients with respiratory system disease in this study area were mostly located in the southeastern regions (Balizhuang sub-district office, Ganjiakou sub-district office, Wanshoulu sub-district office, and Yongdinglu sub-district office) and east-central regions (Zizhuyuan sub-district office and Shuangyushu sub-district office) of the study area. Correspondingly, PM₁ (particulate matter with aerodynamic diameter smaller than 1.0 um) concentrations in these regions were higher than those in any other regions. Grey correlation analysis results showed that the correlation degree of the fine particle concentration with the number of outpatients is high, and the smaller fine particles had more obvious effects on respiratory system disease than larger particles.
Selma, María V; González-Sarrías, Antonio; Salas-Salvadó, Jordi; Andrés-Lacueva, Cristina; Alasalvar, Cesarettin; Örem, Asım; Tomás-Barberán, Francisco A; Espín, Juan C
2018-06-01
Urolithins are microbial metabolites produced after consumption of ellagitannin-containing foods such as pomegranates and walnuts. Parallel to isoflavone-metabolizing phenotypes, ellagitannin-metabolizing phenotypes (urolithin metabotypes A, B and 0; UM-A, UM-B and UM-0, respectively) can vary among individuals depending on their body mass index (BMI), but correlations between urolithin metabotypes (UMs) and cardiometabolic risk (CMR) factors are unexplored. We investigated the association between UMs and CMR factors in individuals with different BMI and health status. UM was identified using UPLC-ESI-qToF-MS in individuals consuming pomegranate or nuts. The associations between basal CMR factors and the urine urolithin metabolomic signature were explored in 20 healthy normoweight individuals consuming walnuts (30 g/d), 49 healthy overweight-obese individuals ingesting pomegranate extract (450 mg/d) and 25 metabolic syndrome (MetS) patients consuming nuts (15 g-walnuts, 7.5 g-hazelnuts and 7.5 g-almonds/d). Correlations between CMR factors and urolithins were found in overweight-obese individuals. Urolithin-A (mostly present in UM-A) was positively correlated with apolipoprotein A-I (P ≤ 0.05) and intermediate-HDL-cholesterol (P ≤ 0.05) while urolithin-B and isourolithin-A (characteristic from UM-B) were positively correlated with total-cholesterol, LDL-cholesterol (P ≤ 0.001), apolipoprotein B (P ≤ 0.01), VLDL-cholesterol, IDL-cholesterol, oxidized-LDL and apolipoprotein B:apolipoprotein A-I ratio (P ≤ 0.05). In MetS patients, urolithin-A only correlated inversely with glucose (P ≤ 0.05). Statin-treated MetS patients with UM-A showed a lipid profile similar to that of healthy normoweight individuals while a poor response to lipid-lowering therapy was observed in MB patients. UMs are potential CMR biomarkers. Overweight-obese individuals with UM-B are at increased risk of cardiometabolic disease, whereas urolithin-A production could protect against CMR factors. Further research is warranted to explore these associations in larger cohorts and whether the effect of lipid-lowering drugs or ellagitannin-consumption on CMR biomarkers depends on individuals' UM. NCT01916239 (https://clinicaltrials.gov/ct2/show/NCT01916239) and ISRCTN36468613 (http://www.isrctn.com/ISRCTN36468613). Copyright © 2017 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
Unit 5, STA. 50+00+RB, Orner Building, First U.M. Church Rectory, ...
Unit 5, STA. 50+00+RB, Orner Building, First U.M. Church Rectory, & First U.M. Church-context - Johnstown Local Flood Protection Project, Beginning on Conemaugh River approx 3.8 miles downstream from confluence of Little Conemaugh & Stony Creek Rivers at Johnstown, Johnstown, Cambria County, PA
VizieR Online Data Catalog: 24um excesses in clusters & membership of NGC2244 (Meng+, 2017)
NASA Astrophysics Data System (ADS)
Meng, H. Y. A.; Rieke, G. H.; Su, K. Y. L.; Gaspar, A.
2017-09-01
We re-measured the Spitzer/MIPS 24um photometry for all the clusters except for a few noted in Appendix A. We obtained the 24um data from the Spitzer Heritage Archive between 2004 Jan 28 and 2008 Oct 23. (3 data files).
VizieR Online Data Catalog: X-ray AGNs with Subaru/FMOS NIR observations (Suh+, 2015)
NASA Astrophysics Data System (ADS)
Suh, H.; Hasinger, G.; Steinhardt, C.; Silverman, J. D.; Schramm, M.
2016-03-01
We performed NIR spectroscopic observations for the AGN sources with the FMOS high-resolution spectrographs on the Subaru telescope; in J-short (0.92-1.12um), J-long (1.11-1.35um), H-short (1.40-1.60um), and H-long (1.60-1.80um) coverage with a spectral resolution of R~2200. The data span the 2012 Mar 25-2013 Oct 24 period. In addition to NIR spectra, we use existing optical spectroscopy (see section 3.2). (2 data files).
VizieR Online Data Catalog: MILO. I. HD 7449 radial velocities (Rodigas+, 2016)
NASA Astrophysics Data System (ADS)
Rodigas, T. J.; Arriagada, P.; Faherty, J.; Anglada-Escude, G.; Kaib, N.; Butler, R. P.; Shectman, S.; Weinberger, A.; Males, J. R.; Morzinski, K. M.; Close, L. M.; Hinz, P. M.; Crane, J. D.; Thompson, I.; Teske, J.; Diaz, M.; Minniti, D.; Lopez-Morales, M.; Adams, F. C.; Boss, A. P.
2016-04-01
We observed HD 7449 using the Magellan Clay Telescope at the Las Campanas Observatory in Chile on the nights of UT 2014 November 5 and 22. We observed the star with VisAO at Ys (0.99um) and with Clio-2 at H (1.65um) and Ks (2.15um) on the first night and with VisAO at r' (0.63um), i' (0.77um), z' (0.91um), and with Clio-2 at J (1.1um) on the second night. RV data on HD 7449 were first acquired as part of the Magellan Planet Search Program, which originally made use of the MIKE echelle spectrometer (R~70000 in the blue and ~50000 in the red; wavelength coverage ranges from 3900 to 6200Å) on the Magellan Clay telescope until 2009 September. HD 7449 was subsequently observed using the Carnegie Magellan/PFS (3880-6680Å with R~80000 in the iodine region). We also included in our analysis RVs measured with HARPS and CORALIE. These RVs were originally reported in Dumusque et al. (2011, J/A+A/535/A55). HARPS data on HD 7449 has been supplemented by the ESO archive. See section 2.2 for further explanations. (1 data file).
Area Handbook Series. Pakistan: A Country Study,
1983-10-01
economic. national security, political, and social systems and institutions and ex - amining the interrelationshins of those systems and institutions...people of Paklsten. For example . the reade wil lAd um.a rather than Ramadan, ,eyd rather than ,md, s." r.athe dn ,aykh. kkod rather da Iud. and em rather...aUend the Constitution to mawe the o11e of the presidency the most powerful post of jsvernmeet (see Ensevgn Political System. ch. 4). He also anounced
Wide-field Astronomy Projects at the UKATC
NASA Astrophysics Data System (ADS)
Hawarden, T. G.; Casali, M. M.; Holland, W. S.; Ivison, R. J.; Wright, G. S.
2001-12-01
The UK Astronomy Technology Centre is engaged on a number of projects which are defining the stare of the art in several areas of wide-field astronomy. The most advanced of these will equip the UK Infrared Telescope (UKIRT) with a wide-field NIR (1 - 2.5 um) imager, WFCAM, in 2003. WFCAM will use 4 2k-square HgCdTe arrays to cover 0.19 square degrees in a single exposure. It will have 0."4 pixels and will employ multiple exposures (16 in the basic case) and microstepping to obtain full sampling of the PSF. WFCAM will reach K=19.4 at 5 sigma over 1 sq. deg. in 1 hour. Several deep surveys are planned; details are at http://www.roe.ac.uk/atc/projects/wfcam/science/. The project is in collaboration with the SUBARU telescope of the National Astronomy Observatory of Japan. Major data centres and archives will be established within the UK widefield astronomy groups and at SUBARU. SCUBA, on the JCMT, is currently the most-cited facility in Astronomy after the HST. Plans and technology development are well advanced for its replacement, SCUBA-2. This ambitious instrument is also an imager working at 450 and 850 um, but with greatly enlarged FOV and improved sensitivity. Technical developments at the NIST, Boulder, Co. are aimed at producing 2 6400-pixel arrays of Transition Edge Sensors, covering 8' x 8', with a system NEFD of 30mJy at 850 and 100 mJy at 450um. The 850 um FOV will be fully sampled; the 450 um FOV will be 2X undersampled. SCUBA-2 will be able to make a confusion-limited survey of 1 ° 2 of sky in just 24 hours of observing; indeed it will map large areas of sky up to an order of magnitude faster than ALMA in compact mode; it will make major new contributions to all areas of astronomy, from the solar system to Z=10 galaxies. Lastly, designs are well advanced for a powerful multiple cryogenic Integral Field spectroscopic facility. The design is well suited to VLTs or ELTs and will employ up to 8 unit spectrometers, each with a 2k2 array fed by four cryogenic deployable optical feed arms. These use a simple design to maintain a constant optical path length while placing the input apertures for the Integral Field Units anywhere in a 10' field of view.
Development of KIAPS Observation Processing Package for Data Assimilation System
NASA Astrophysics Data System (ADS)
Kang, Jeon-Ho; Chun, Hyoung-Wook; Lee, Sihye; Han, Hyun-Jun; Ha, Su-Jin
2015-04-01
The Korea Institute of Atmospheric Prediction Systems (KIAPS) was founded in 2011 by the Korea Meteorological Administration (KMA) to develop Korea's own global Numerical Weather Prediction (NWP) system as nine year (2011-2019) project. Data assimilation team at KIAPS has been developing the observation processing system (KIAPS Package for Observation Processing: KPOP) to provide optimal observations to the data assimilation system for the KIAPS Global Model (KIAPS Integrated Model - Spectral Element method based on HOMME: KIM-SH). Currently, the KPOP is capable of processing the satellite radiance data (AMSU-A, IASI), GPS Radio Occultation (GPS-RO), AIRCRAFT (AMDAR, AIREP, and etc…), and synoptic observation (SONDE and SURFACE). KPOP adopted Radiative Transfer for TOVS version 10 (RTTOV_v10) to get brightness temperature (TB) for each channel at top of the atmosphere (TOA), and Radio Occultation Processing Package (ROPP) 1-dimensional forward module to get bending angle (BA) at each tangent point. The observation data are obtained from the KMA which has been composited with BUFR format to be converted with ODB that are used for operational data assimilation and monitoring at the KMA. The Unified Model (UM), Community Atmosphere - Spectral Element (CAM-SE) and KIM-SH model outputs are used for the bias correction (BC) and quality control (QC) of the observations, respectively. KPOP provides radiance and RO data for Local Ensemble Transform Kalman Filter (LETKF) and also provides SONDE, SURFACE and AIRCRAFT data for Three-Dimensional Variational Assimilation (3DVAR). We are expecting all of the observation type which processed in KPOP could be combined with both of the data assimilation method as soon as possible. The preliminary results from each observation type will be introduced with the current development status of the KPOP.
Advanced Seal Delivery System: Perspectives and Options
2006-01-01
in that order of importance. Once cracked by whatever mechanism, alloy 6-4 titanium (unlike some other titani - um materials) will fail immediately...NGC and its potential subcontractors is not as effective as it could be. Given the early history of the ASDS program, it does not surprise us that
Life-cycle optimization model for distributed generation in buildings
NASA Astrophysics Data System (ADS)
Safaei, Amir
O setor da construcao e responsavel por uma grande parte do consumo de energia e emissoes na Uniao Europeia. A Geracao Distribuida (GD) de energia, nomeadamente atraves de sistemas de cogeracao e tecnologias solares, representa um papel importante no futuro energetico deste setor. A otimizacao do funcionamento dos sistemas de cogeracao e uma tarefa complexa, devido as diversas variaveis em jogo, designadamente: os diferentes tipos de necessidades energeticas (eletricidade, aquecimento e arrefecimento), os precos dinamicos dos combustiveis (gas natural) e da eletricidade, e os custos fixos e variaveis dos diferentes sistemas de GD. Tal torna-se mais complexo considerando a natureza flutuante das tecnologias solares termicas e fotovoltaicas. Ao mesmo tempo, a liberalizacao do mercado da eletricidade permite exportar para a rede, a electricidade gerada localmente. Adicionalmente, a operacao estrategica de um sistema de GD deve atender aos quadros politicos nacionais, se tiver como objetivo beneficiar de tais regimes. Alem disso, considerando os elevados impactes ambientais do setor da construcao, qualquer avaliacao energetica de edificios rigorosa deve tambem integrar aspetos ambientais, utilizando uma abordagem de Ciclo de Vida (CV). Uma avaliacao de Ciclo de Vida (ACV) completa de um sistema de GD deve incluir as fases relativas a operacao e construcao do sistema, bem como os impactes associados a producao dos combustiveis. Foram analisadas as emissoes da producao de GN, as quais variam de acordo com a origem, tipo (convencional ou nao-convencional), e estado (na forma de GN Liquefeito (GNL) ou gas). Do mesmo modo, o impacte dos sistemas solares e afetado pela meteorologia e radiacao solar, de acordo com a sua localizacao geografica. Sendo assim, uma avaliacao adequada dos sistemas de GD exige um modelo de ACV adequado a localizacao geografica (Portugal), integrando tambem a producao de combustivel (GN), tendo em conta as suas diferentes fontes de abastecimento. O principal objetivo desta tese de doutoramento foi desenvolver um modelo para otimizar o desenho e operacao de sistemas de GD para o setor da construcao de edificios comerciais em Portugal, considerando os respetivos Impactes de Ciclo de Vida (IAVC) e Custos de Ciclo de Vida (CCV), de modo a satisfazer as necessidades energeticas do edificio. Tres tipos de tecnologias de cogeracao (Micro-Turbinas, Motores de combustao interna, e Celulas combustiveis de Oxido solido), e dois tipos de tecnologias de energia solar, solar termica e fotovoltaica, constituem os sistemas de GD que sao acoplados aos sistemas convencionais. Foi desenvolvido um modelo de CV, tendo em conta todos os impactes relacionados com a construcao e operacao dos sistemas de energia, bem como os processos a montante relacionados com a producao do GN. Em particular, o mix de GN consumido em Portugal em 2011 foi identificado (60% da Nigeria, 40% da Argelia) e os impactes relativos a cada uma das vias de abastecimento foram avaliados separadamente para quatro categorias de impacte ambiental: Consumo de Energia Primaria (CEP), Gases com Efeito de Estufa (GEE), acidificacao, e eutrofizacao. Devido a importancia das emissoes de GEE na formulacao de politicas, foi tambem realizada uma analise de incerteza as emissoes de GEE do GN fornecido a Portugal. Foi desenvolvido um modelo matematico, em linguagem de Programacao General Algebraic Modeling System (GAMS), que utiliza os resultados da ACV dos sistemas de energia e as suas implicacoes economicas para minimizar o CCV e IACV ao longo de um horizonte de planeamento definido pelo decisor. Foram derivadas fronteiras otimas de Pareto, representando as relacoes entre o tipo de IACV (CEP, GEE, acidificacao, eutrofizacao) e CCV decorrentes da satisfacao das necessidades energeticas do edificio. Para aumentar a robustez do modelo, dada a incerteza dos precos dos combustiveis (GN e eletricidade), foi desenvolvido um modelo de custos robusto para os sistemas de GD, que e menos afetado por perturbacoes relativas aos custos de combustivel. A aplicacao do modelo proposto foi testada num caso de estudo real, um edificio comercial localizado na cidade de Coimbra, em Portugal.
Ga Lithography in Sputtered Niobium for Superconductive Micro and Nanowires.
Henry, Michael David; Lewis, Rupert M.; Wolfley, Steven L.; ...
2014-08-18
This work demonstrates the use of FIB implanted Ga as a lithographic mask for plasma etching of Nb films. Using a highly collimated Ga beam of a FIB, Nb is implanted 12 nm deep with a 14 nm thick Ga layer providing etch selectivity better than 15:1 with fluorine based etch chemistry. Implanted square test patterns, both 10 um by and 10 um and 100 um by 100 um, demonstrate that doses above than 7.5 x 1015 cm-2 at 30 kV provide adequate mask protection for a 205 nm thick, sputtered Nb film. The resolution of this dry lithographic techniquemore » is demonstrated by fabrication of nanowires 75 nm wide by 10 um long connected to 50 um wide contact pads. The residual resistance ratio of patterned Nb films was 3. The superconducting transition temperature, Tc =7.7 K, was measured using MPMS. This nanoscale, dry lithographic technique was extended to sputtered TiN and Ta here and could be used on other fluorine etched superconductors such as NbN, NbSi, and NbTi.« less
2011-03-23
sensors (e.g., sensor fusion) or use different detector materials to increase spectral bands into the Near IR (NIR). 3. Holst2provides an...a. Detector type: Multi-element MCT SPRITE b. Wavelength: Long wave, 8-12 um c. Cooling system: Integrated Sterling cooler d. Cooldown...A-1 B. COLLIMATOR SYSTEM DESIGN AND EO/ IR TOPICS ................ B-1 C. ATTC FACILITIES AND INSTRUMENTATION
NASA Astrophysics Data System (ADS)
Nontapot, Kanokwan
2018-03-01
The carbon dioxide laser (CO2 laser) is one of the most useful and is the highest CW laser at the present. The laser produces infrared light at 10.6 um. Due to its high power, CO2 lasers are usually used in industrial applications such as cutting and welding, or for engraving at less power. CO2 lasers are also used widely in medical applications, such as laser surgery, skin resurfacing, and removing mold, due to water (biological tissue) absorb light at this wavelength very well. CO2 lasers are also used as LIDAR laser source for military range finding applications because of the transparency of the atmosphere to infrared light. Due to the increasing use of CO2 lasers laser in industrial and medical applications in Thailand, the National Institute of Metrology (Thailand) has set up a CO2 laser power calibration system and provide calibration service to customers this year. The service support calibration of medium-level laser power at wavelength of 10.6 um and at power range 100 mW-10W. The design and development of the calibration system will be presented.
VizieR Online Data Catalog: Reflectance spectra of 12 Trojans and Hildas (Marsset+, 2014)
NASA Astrophysics Data System (ADS)
Marsset, M.; Vernazza, P.; Gourgeot, F.; Dumas, C.; Birlan, M.; Lamy, P.; Binzel, R. P.
2014-07-01
We present 17 reflectance spectra of 12 high albedo (pv>0.14) Trojans (8 objects) and Hildas (4 objects) obtained with the ESO/VLT Echelle spectrograph X-SHOOTER in the 0.3-2.2um spectral range (14 spectra) and with the NASA/IRTF spectrograph SpeX in the 0.8-2.5um spectral range (3 spectra). X-SHOOTER spectra were normalized to unity at 0.55um and SpeX spectra were normalized to unity at 2.2um . The spectra presented in this work were collected between April and December 2013. (18 data files).
Guarini, Anna; Chiaretti, Sabina; Tavolaro, Simona; Maggio, Roberta; Peragine, Nadia; Citarella, Franca; Ricciardi, Maria Rosaria; Santangelo, Simona; Marinelli, Marilisa; De Propris, Maria Stefania; Messina, Monica; Mauro, Francesca Romana; Del Giudice, Ilaria; Foà, Robert
2008-08-01
Chronic lymphocytic leukemia (CLL) patients exhibit a variable clinical course. To investigate the association between clinicobiologic features and responsiveness of CLL cells to anti-IgM stimulation, we evaluated gene expression changes and modifications in cell-cycle distribution, proliferation, and apoptosis of IgV(H) mutated (M) and unmutated (UM) samples upon BCR cross-linking. Unsupervised analysis highlighted a different response profile to BCR stimulation between UM and M samples. Supervised analysis identified several genes modulated exclusively in the UM cases upon BCR cross-linking. Functional gene groups, including signal transduction, transcription, cell-cycle regulation, and cytoskeleton organization, were up-regulated upon stimulation in UM cases. Cell-cycle and proliferation analyses confirmed that IgM cross-linking induced a significant progression into the G(1) phase and a moderate increase of proliferative activity exclusively in UM patients. Moreover, we observed only a small reduction in the percentage of subG(0/1) cells, without changes in apoptosis, in UM cases; contrariwise, a significant increase of apoptotic levels was observed in stimulated cells from M cases. These results document that a differential genotypic and functional response to BCR ligation between IgV(H) M and UM cases is operational in CLL, indicating that response to antigenic stimulation plays a pivotal role in disease progression.
NE VIII lambda 774 and time variable associated absorption in the QSO UM 675
NASA Technical Reports Server (NTRS)
Hamann, Fred; Barlow, Thomas A.; Beaver, E. A.; Burbidge, E. M.; Cohen, Ross D.; Junkkarinen, Vesa; Lyons, R.
1995-01-01
We discuss measurements of Ne VIII lambda 774 absorption and the time variability of other lines in the z(sub a) approximately equal z(sub e) absorption system of the z(sub e) = 2.15 QSO UM 675 (0150-203). The C IV lambda 1549 and N V 1240 doublets at z(sub a) = 2.1340 (shifted approximately 1500 km/s from z(sub e) strengthened by a factor of approximately 3 between observations by Sargent, Boksenberg and Steidel (1981 November) and our earliest measurements (1990 November and December). We have no information on changes in other z(sub a) approximately equal z(sub e) absorption lines. Continued monitoring since 1990 November shows no clear changes in any of the absorptions between approximately 1100 and 1640 A rest. The short timescale of the variability (less than or approximately equal to 2.9 yr rest) strongly suggests that the clouds are dense, compact, close to the QSO, and photoionized by the QSO continuum. If the line variability is caused by changes in the ionization, the timescale requires densities greater than approximately 4000/cu cm. Photoionization calculations place the absorbing clouds within approximately 200 pc of the continuum source. The full range of line ionizations (from Ne VIII lambda 774 to C III lambda 977) in optically thin gas (no Lyman limit) implies that the absorbing regions span a factor of more than approximately 10 in distance or approximately 100 in density. Across these regions, the total hydrogen (H I + H II) column ranges from a few times 10(exp 18)/sq cm in the low-ionization gas to approximately 10(exp 20)/sq cm where the Ne VIII doublet forms. The metallicity is roughly solar or higher, with nitrogen possibly more enhanced by factors of a few. The clouds might contribute significant line emission if they nearly envelop the QSO. The presence of highly ionized Ne VIII lambda 774 absorption near the QSO supports recent studies that link z(sub a) approximately equal to z(sub e) systems with X-ray 'wamr absorbers. We show that the Ne VIII absorbing gas would itself produce measurable warm absorption -- characterized by bound-free O VII or O VIII edegs near 0.8 keV -- if the column densities were N(sub H) greater than or approximately equal to 10(exp 21)/sq cm (for solar abundances).
NE VIII lambda 774 and time variable associated absorption in the QSO UM 675
NASA Astrophysics Data System (ADS)
Hamann, Fred; Barlow, Thomas A.; Beaver, E. A.; Burbidge, E. M.; Cohen, Ross D.; Junkkarinen, Vesa; Lyons, R.
1995-04-01
We discuss measurements of Ne VIII lambda 774 absorption and the time variability of other lines in the za approximately equal ze absorption system of the ze = 2.15 QSO UM 675 (0150-203). The C IV lambda 1549 and N V 1240 doublets at za = 2.1340 (shifted approximately 1500 km/s from ze strengthened by a factor of approximately 3 between observations by Sargent, Boksenberg and Steidel (1981 November) and our earliest measurements (1990 November and December). We have no information on changes in other za approximately equal ze absorption lines. Continued monitoring since 1990 November shows no clear changes in any of the absorptions between approximately 1100 and 1640 A rest. The short timescale of the variability (less than or approximately equal to 2.9 yr rest) strongly suggests that the clouds are dense, compact, close to the QSO, and photoionized by the QSO continuum. If the line variability is caused by changes in the ionization, the timescale requires densities greater than approximately 4000/cu cm. Photoionization calculations place the absorbing clouds within approximately 200 pc of the continuum source. The full range of line ionizations (from Ne VIII lambda 774 to C III lambda 977) in optically thin gas (no Lyman limit) implies that the absorbing regions span a factor of more than approximately 10 in distance or approximately 100 in density. Across these regions, the total hydrogen (H I + H II) column ranges from a few times 1018/sq cm in the low-ionization gas to approximately 1020/sq cm where the Ne VIII doublet forms. The metallicity is roughly solar or higher, with nitrogen possibly more enhanced by factors of a few. The clouds might contribute significant line emission if they nearly envelop the QSO. The presence of highly ionized Ne VIII lambda 774 absorption near the QSO supports recent studies that link za approximately equal to ze systems with X-ray 'wamr absorbers. We show that the Ne VIII absorbing gas would itself produce measurable warm absorption -- characterized by bound-free O VII or O VIII edegs near 0.8 keV -- if the column densities were NH greater than or approximately equal to 1021/sq cm (for solar abundances).
NASA Astrophysics Data System (ADS)
Hamilton, V. E.; McDowell, M. L.; Berger, J. A.; Cady, S. L.; Knauth, L. P.
2011-12-01
We have collected visible to near infrared reflectance (VNIR, ~0.4 - 2.5 um), thermal infrared emissivity (TIR, ~5 - 45 um), SEM, XRD, surface roughness, and petrographic data for 18 silica samples. These rocks (e.g., replacement chert, geyserite, opal-A/-CT) represent a variety of geologic formation environments, including hydrothermal, and have XRD-determined crystallinities ranging from <1 to >10 according to the quartz crystallinity index. Our findings are relevant to the interpretation of orbital and in situ spectral observations of crystalline or amorphous silica on the Martian surface, some of which may have formed in hydrothermal systems. Almost all of our samples' VNIR spectra contain discernible bands. The most common features are related to hydration (H2O and/or OH) of silica (e.g., at ~1.4, 1.9, and 2.2 um). The visibility and strength of these bands is not always constant between spectra from different areas of a sample. Other features include those of carbonate, phyllosilicate, and iron oxide impurities. All of our amorphous silica samples have hydration features in the VNIR, but we note that the absorptions around ~2.2 um can be very weak in amorphous samples relative to features at other wavelengths and relative to ~2.2-um features observed in Martian data, suggesting that some amorphous silica on Mars could go undetected. Deposits containing significant anhydrous, crystalline silica (chert) may be assumed to lack features in the VNIR, but many of our cherts have spectral features and could be misidentified as materials dominated by what is a minor contaminant. Thermal infrared spectra of chert and opaline silica differ from each other as a result of the loss of long-range Si-O order in increasingly amorphous samples. Our samples display a clear trend in TIR band shapes where features attributable to crystalline quartz and amorphous silica are blended in samples with intermediate crystallinities. Most diagnostic TIR spectral features observable in laboratory data typically are recognizable in hyperspectral remote sensing data. These features are more difficult to distinguish (or are not included) at multispectral resolutions, but in nearly all uncontaminated samples, the positions of Si-O emissivity minima shift towards longer wavelengths with decreasing crystallinity. Contaminating phases with strong VNIR spectral features are observed in some of the TIR spectra but have a negligible effect in others, suggesting that TIR spectroscopy helps constrain the abundances of these phases. In addition to compositional and crystallinity information, our laboratory data demonstrate that TIR spectra can be used to deduce important information on silica phases' texture and orientation. If used in combination, VNIR and TIR spectroscopy can detect and characterize silica phases, allowing us to estimate conditions of silica formation, e.g., high- or low-temperature aqueous systems.
Unmanned air vehicle (UAV) ultra-persitence research
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dron, S. B.
2012-03-01
Sandia National Laboratories and Northrop Grumman Corporation Integrated Systems, Unmanned Systems (NGIS UMS) collaborated to further ultra-persistence technologies for unmanned air vehicles (UAVs). The greatest shortfalls in UAV capabilities have been repeatedly identified as (1) insufficient flight persistence or 'hang time,' (2) marginal electrical power for running higher power avionics and payload systems, and (3) inadequate communications bandwidth and reach. NGIS UMS requested support from Sandia to develop an ultra-persistent propulsion and power system (UP3S) for potential incorporation into next generation UAV systems. The team members tried to determine which energy storage and power generation concepts could most effectively pushmore » UAV propulsion and electrical power capabilities to increase UAV sortie duration from days to months while increasing available electrical power at least two-fold. Primary research and development areas that were pursued included these goals: perform general system engineering and integration analyses; develop initial thermal and electrical power estimates; provide mass, volume, dimensional, and balance estimates; conduct preliminary safety assessments; assess logistics support requirements; perform, preliminary assessments of any security and safeguards; evaluate options for removal, replacement, and disposition of materials; generally advance the potential of the UP3S concept. The effort contrasted and compared eight heat sources technologies, three power conversion, two dual cycle propulsion system configurations, and a single electrical power generation scheme. Overall performance, specific power parameters, technical complexities, security, safety, and other operational features were successfully investigated. Large and medium sized UAV systems were envisioned and operational flight profiles were developed for each concept. Heat source creation and support challenges for domestic and expeditionary operations were considered. Fundamental cost driver analysis was also performed. System development plans were drafted in order to determine where the technological and programmatic critical paths lay. As a result of this effort, UAVs were to be able to provide far more surveillance time and intelligence information per mission while reducing the high cost of support activities. This technology was intended to create unmatched global capabilities to observe and preempt terrorist and weapon of mass destruction (WMD) activities. Various DOE laboratory and contractor personnel and facilities could have been used to perform detailed engineering, fabrication, assembly and test operations including follow-on operational support. Unfortunately, none of the results will be used in the near-term or mid-term future. NGIS UMS and SNL felt that the technical goals for the project were accomplished. NGIS UMS was quite pleased with the results of analysis and design although it was disappointing to all that the political realities would not allow use of the results. Technology and system designs evaluated under this CRADA had previously never been applied to unmanned air vehicles (UAVs). Based upon logistic support cost predictions, because the UAVs would not have had to refuel as often, forward basing support costs could have been reduced due to a decrease in the number and extent of support systems and personnel being required to operate UAVs in remote areas. Basic application of the advanced propulsion and power approach is well understood and industry now understands the technical, safety, and political issues surrounding implementation of these strategies. However, the overall economic impact was not investigated. The results will not be applied/implemented. No near-term benefit to industry or the taxpayer will be encountered as a result of these studies.« less
"Uh" and "Um" Revisited: Are They Interjections for Signaling Delay?
ERIC Educational Resources Information Center
O'Connell, Daniel C.; Kowal, Sabine
2005-01-01
Clark and Fox Tree (2002) have presented empirical evidence, based primarily on the London-Lund corpus (LL; Svartvik & Quirk, 1980), that the fillers "uh" and "um" are conventional English words that signal a speaker's intention to initiate a minor and a major delay, respectively. We present here empirical analyses of "uh" and "um" and of silent…
Demedts, Dennis; Roelands, Marc; Libbrecht, Julien; Bilsen, Johan
2018-05-26
Euthanasia because of unbearable mental suffering (UMS euthanasia) has been legal in Belgium since 2002, under certain circumstances that govern careful practice. Despite the legal framework, there are specific difficulties and concerns regarding UMS euthanasia. Mental health nurses are often involved in the process, but little is known about their attitudes towards UMS euthanasia, their role and their knowledge. To determine the attitudes, role and knowledge of mental health nurses regarding UMS euthanasia. A cross-sectional survey was performed at a convenience sample of four psychiatric hospitals in Belgium (n=133) as a pilot study. Self-administered questionnaires were provided to mental health nurses. Half the nurses in our sample had been involved at least once in the process of UMS euthanasia. A large majority of mental health nurses were supportive of UMS euthanasia. Nurses show differences in attitudes related to the different psychiatric pathologies of the patients, and in whether or not minors are involved. In some cases, they believed that the mental suffering of psychiatric patients can be unbearable and irreversible and that psychiatric patients can be competent to voluntarily request UMS euthanasia. Nurses stated that they have an important role in the UMS euthanasia process, but also demanded more knowledge and clear guidelines to implement the procedure. Nurses have a key role regarding UMS euthanasia but face several challenges: the recent process, resistance to a multidisciplinary approach by psychiatrists and an unclear role defined by the legal framework. Nurses do not appear to have a common voice on the topic and the development of clear guidelines appears to be essential. Social recovery can offer a way out of an UMS euthanasia request, but it will not always offer a solution. Sufficient attention must be paid to how mental health nurses can be involved in the process of UMS euthanasia at various levels: bedside practice, healthcare management, education and policy. A form of systematic cooperation between nurses, physicians and patients can contribute to the utmost careful decision-making process needed in these cases. There is a need for proper training in: knowledge of psychiatric pathologies and remaining treatment options; communication skills; the legal framework and all its difficulties; transdisciplinary and multicultural approaches; ethical reflection and how nurses handle their own emotions. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Brundiek, Henrike; Saß, Stefan; Evitt, Andrew; Kourist, Robert; Bornscheuer, Uwe T
2012-04-01
The Ustilago maydis lipase UM03410 belongs to the mostly unexplored Candida antarctica lipase (CAL-A) subfamily. The two lipases with [corrected] the highest identity are a lipase from Sporisorium reilianum and the prototypic CAL-A. In contrast to the other CAL-A-type lipases, this hypothetical U. maydis lipase is annotated to possess a prolonged N-terminus of unknown function. Here, we show for the first time the recombinant expression of two versions of lipase UM03410: the full-length form (lipUMf) and an Nterminally truncated form (lipUMs). For comparison to the prototype, the expression of recombinant CAL-A in E. coli was investigated. Although both forms of lipase UM03410 could be expressed functionally in E. coli, the N-terminally truncated form (lipUMs) demonstrated significantly higher activities towards p-nitrophenyl esters. The functional expression of the N-terminally truncated lipase was further optimized by the appropriate choice of the E. coli strain, lowering the cultivation temperature to 20 °C and enrichment of the cultivation medium with glucose. Primary characteristics of the recombinant lipase are its pH optimum in the range of 6.5-7.0 and its temperature optimum at 55 °C. As is typical for lipases, lipUM03410 shows preference for long chain fatty acid esters with myristic acid ester (C14:0 ester) being the most preferred one.More importantly, lipUMs exhibits an inherent preference for C18:1Δ9 trans and C18:1Δ11 trans-fatty acid esters similar to CAL-A. Therefore, the short form of this U. maydis lipase is the only other currently known lipase with a distinct trans-fatty acid selectivity.
Uh and um revisited: are they interjections for signaling delay?
O'Connell, Daniel C; Kowal, Sabine
2005-11-01
Clark and Fox Tree (2002) have presented empirical evidence, based primarily on the London-Lund corpus (LL; Svartvik & Quirk, 1980), that the fillers uh and um are conventional English words that signal a speaker's intention to initiate a minor and a major delay, respectively. We present here empirical analyses of uh and um and of silent pauses (delays) immediately following them in six media interviews of Hillary Clinton. Our evidence indicates that uh and um cannot serve as signals of upcoming delay, let alone signal it differentially: In most cases, both uh and um were not followed by a silent pause, that is, there was no delay at all; the silent pauses that did occur after um were too short to be counted as major delays; finally, the distributions of durations of silent pauses after uh and um were almost entirely overlapping and could therefore not have served as reliable predictors for a listener. The discrepancies between Clark and Fox Tree's findings and ours are largely a consequence of the fact that their LL analyses reflect the perceptions of professional coders, whereas our data were analyzed by means of acoustic measurements with the PRAAT software (www.praat.org). A comparison of our findings with those of O'Connell, Kowal, and Ageneau (2005) did not corroborate the hypothesis of Clark and Fox Tree that uh and um are interjections: Fillers occurred typically in initial, interjections in medial positions; fillers did not constitute an integral turn by themselves, whereas interjections did; fillers never initiated cited speech, whereas interjections did; and fillers did not signal emotion, whereas interjections did. Clark and Fox Tree's analyses were embedded within a theory of ideal delivery that we find inappropriate for the explication of these phenomena.
González-Sarrías, Antonio; García-Villalba, Rocío; Romo-Vaquero, María; Alasalvar, Cesarettin; Örem, Asim; Zafrilla, Pilar; Tomás-Barberán, Francisco A; Selma, María V; Espín, Juan Carlos
2017-05-01
The pomegranate lipid-lowering properties remain controversial, probably due to the interindividual variability in polyphenol (ellagitannins) metabolism. We aimed at investigating whether the microbially derived ellagitannin-metabolizing phenotypes, i.e. urolithin metabotypes A, (UM-A), B (UM-B), and 0 (UM-0), influence the effects of pomegranate extract (PE) consumption on 18 cardiovascular risk biomarkers in healthy overweight-obese individuals. A double-blind, crossover, dose-response, randomized, placebo-controlled trial was conducted. The study (POMEcardio) consisted of two test phases (dose-1 and dose-2, lasting 3 weeks each) and a 3-week washout period between each phase. Forty-nine participants (BMI > 27 kg/m 2 ) daily consumed one (dose-1, 160 mg phenolics/day) or four (dose-2, 640 mg phenolics/day) PE or placebo capsules. Notably, UM-B individuals showed the highest baseline cardiovascular risk. After dose-2, total cholesterol (-15.5 ± 3.7%), LDL-cholesterol (-14.9 ± 2.1%), small LDL-cholesterol (-47 ± 7%), non-HDL-cholesterol (-11.3 ± 2.5%), apolipoprotein-B (-12 ± 2.2%), and oxidized LDL-cholesterol -24 ± 2.5%) dose dependently decreased (P < 0.05) but only in UM-B subjects. These effects were partially correlated with urolithin production and the increase in Gordonibacter levels. Three (50%) nonproducers (UM-0) became producers following PE consumption. UM clustering suggests a personalized effect of ellagitannin-containing foods and could explain the controversial pomegranate benefits. Research on the specific role of urolithins and the microbiota associated with each UM is warranted. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Mor, Zohar; Raveh, Yuval; Lurie, Ido; Leventhal, Alex; Gamzu, Roni; Davidovitch, Nadav; Benari, Orel; Grotto, Itamar
2017-07-14
Approximately 150,000 undocumented migrants (UM) who are medically uninsured reside in Israel, including ~50,000 originating from the horn of Africa (MHA). Free medical-care is provided by two walk-in clinics in Tel-Aviv. This study aims to compare the medical complaints of UM from different origins, define their community health needs and assess gaps between medical needs and available services. This cross-sectional study included a random sample of 610 UM aged 18-64 years, who were treated in these community clinics between 2008 and 2011. The study compared UM who had complex medical conditions which necessitated referral to more equipped medical settings with UM having mild/simple medical conditions, who were treated at the clinics. MHA were younger, unemployed and more commonly males compared with UM originating from other countries. MHA also had longer referral-delays and visited the clinics less frequently. UM with complex medical conditions were more commonly females, had chronic diseases and demonstrated longer referral-delays than those who had mild/simple medical conditions. The latter more commonly presented with complained of respiratory, muscular and skeletal discomfort. In multivariate analysis, the variables which predicted complex medical conditions included female gender, chronic illnes and self-referral to the clinics. The ambulatory clinics were capable of responding to mild/simple medical conditions. Yet, the health needs of women and migrants suffering from complex medical conditions and chronic diseases necessitated referrals to secondary/tertiary medical settings, while jeopardizing the continuity of care. The health gaps can be addressed by a more holistic social approach, which includes integration of UM in universal health insurance.
Refractive index sensor based on the leaky radiation of a microfiber.
Gao, F; Liu, H; Sheng, C; Zhu, C; Zhu, S N
2014-05-19
In this work we present a refractive index sensor based on the leaky radiation of a microfiber. The 5.3um diameter microfiber is fabricated by drawing a commercial optical fiber. When the microfiber is immersed into a liquid with larger refractive index than the effective index of fiber mode, the light will leak out through the leaky radiation process. The variation of refractive index of liquid can be monitored by measuring radiation angle of light. The refractive index sensitivity can be over 400 degree/RIU in theory. In the experiment, the variation value 0.001 of refractive index of liquid around this microfiber can be detected through this technique. This work provides a simple and sensitive method for refractive index sensing application.
High-speed, large-area, p-i-n InGaAs photodiode linear array at 2-micron wavelength
NASA Astrophysics Data System (ADS)
Joshi, Abhay; Datta, Shubhashish
2012-06-01
We present 16-element and 32-element lattice-mismatched InGaAs photodiode arrays having a cut-off wavelength of ~2.2 um. Each 100 um × 200 um large pixel of the 32-element array has a capacitance of 2.5 pF at 5 V reverse bias, thereby allowing a RC-limited bandwidth of ~1.3 GHz. At room temperature, each pixel demonstrates a dark current of 25 uA at 5 V reverse bias. Corresponding results for the 16-element array having 200 um × 200 um pixels are also reported. Cooling the photodiode array to 150K is expected to reduce its dark current to < 50 nA per pixel at 5 V reverse bias. Additionally, measurement results of 2-micron single photodiodes having 16 GHz bandwidth and corresponding PIN-TIA photoreceiver having 6 GHz bandwidth are also reported.
Risk stratification for death and all-cause hospitalization in heart failure clinic outpatients.
Hummel, Scott L; Ghalib, Hussam H; Ratz, David; Koelling, Todd M
2013-11-01
Most heart failure (HF) risk stratification models were developed for inpatient use, and available outpatient models use a complex set of variables. We hypothesized that routinely collected clinical data could predict the 6-month risk of death and all-cause medical hospitalization in HF clinic outpatients. Using a quality improvement database and multivariable Cox modeling, we derived the Heart Failure Patient Severity Index (HFPSI) in the University of Michigan HF clinic (UM cohort, n = 1,536; 314 reached primary outcome). We externally validated the HFPSI in the Ann Arbor Veterans' Affairs HF clinic (VA cohort, n = 445; 106 outcomes) and explored "real-time" HFPSI use (VA-RT cohort, n = 486; 141 outcomes) by tracking VA patients for 6 months from their most recently calculated HFPSI, rather than using an arbitrary start date for the cohort. The HFPSI model included blood urea nitrogen, B-type natriuretic peptide, New York Heart Association class, diabetes status, history of atrial fibrillation/flutter, and all-cause hospitalization within the prior 1 and 2 to 6 months. The concordance c statistics in the UM/VA/VA-RT cohorts were 0.71/0.68/0.74. Kaplan-Meier curves and log-rank testing demonstrated excellent risk stratification, particularly between a large, low-risk group (40% of patients, 6-month event rates in the UM/VA/VA-RT cohorts 8%/12%/12%) and a small, high-risk group (10% of patients, 6-month event rates in the UM/VA/VA-RT cohorts 57%/58%/79%). The HFPSI uses readily available data to predict the 6-month risk of death and/or all-cause medical hospitalization in HF clinic outpatients and could potentially help allocate specialized HF resources within health systems. © 2013.
NASA Astrophysics Data System (ADS)
Higdon, S. J. U.; Weedman, D.; Higdon, J. L.; Houck, J. R.; Soifer, B. T.; Armus, L.; Charmandaris, V.; Herter, T. L.; Brandl, B. R.; Brown, M. J. I.; Dey, A.; Jannuzi, B.; Le Floc'h, E.; Rieke, M.
2004-12-01
We have surveyed a field covering 8.4 degrees2 within the NOAO Deep Wide Field Survey region in Boötes with the Multiband Imaging Photometer on the Spitzer Space Telescope to a limiting 24 um flux density of 0.3 mJy, identifying ˜ 22,000 point sources. Thirty one sources from this survey with F(24 um) > 0.75 mJy , which are optically ``invisible'' (R > 26) or very faint (I > 24) have been observed with the low-resolution modules of the Infrared Spectrograph on SST. The spectra were extracted using the IRS SMART spectral analysis package in order to optimize their signal to noise. A suite of mid-IR spectral templates of well known galaxies, observed as part of the IRS GTO program, is used to perform formal fits to the spectral energy distribution of the Boötes sources. These fits enable us to measure their redshift, to calculate the depth of the 9.7 um silicate feature along with the strength of 7.7 um PAH, as well as to estimate their bolometric luminosities. We compare the mid-IR slope, the measured PAH luminosity, and the optical depth of these sources with those of galaxies in the local Universe. As a result we are able to estimate the contribution of a dust enshrouded active nucleus to the mid-IR and bolometric luminosity of these systems. This work is based [in part] on observations made with the Spitzer Space Telescope, which is operated by the Jet Propulsion Laboratory, California Institute of Technology under NASA contract 1407. Support for this work was provided by NASA through Contract Number 1257184 issued by JPL/Caltech.
NASA Technical Reports Server (NTRS)
2002-01-01
Full resolution visible and near-infrared image (1.4 MB) Full resolution shortwave infrared image (1.6 MB) This Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) image covers 30 by 23 km (full images 30 x 37 km) in the Atacama Desert, Chile, and was acquired on April 23, 2000. The Escondida copper, gold, and silver open-pit mine is at an elevation of 3050 m, and began operations in 1990. Current capacity is 127,000 tons/day of ore; in 1999 production totaled 827,000 tons of copper, 150,000 ounces of gold, and 3.53 million ounces of silver. Primary concentrate of the ore is done on-site; the concentrate is then sent to the coast for further processing through a 170 km long, 9-inch pipe. Escondida is related geologically to three porphyry bodies intruded along the Chilean West Fissure Fault System. A high grade supergene cap overlies primary sulfide ore. The top image is a conventional 3-2-1 (near infrared, red, green) RGB composite. The bottom image displays shortwave infrared bands 4-6-8 (1.65um, 2.205um, 2.33um) in RGB, and highlights the different rock types present on the surface, as well as the changes caused by mining. Image courtesy NASA/GSFC/MITI/ERSDAC/JAROS, and U.S./Japan ASTER Science Team
The reductive dehalogenation of hexachloroethane (C2CI6), carbon tetrachloride (CC14), and bromoform (CHBr3) was examined at 50 degrees C in aqueous solutions containing either (1) 500 uM of 2,6-anthrahydroquinone disulfonate (AHQDS), (2) 250 uM Fe2+, or (3) 250 uM HS. The pH ran...
Assessment of Teams and Teamwork in the University of Maryland Libraries
ERIC Educational Resources Information Center
Baughman, M. Sue
2008-01-01
Teams play an important role in the University of Maryland (UM) Libraries. Since 1998, teams and collaborative teamwork have become the way librarians address the myriad of issues affecting the needs of UM's faculty, students, and staff. There has been much change in the UM Libraries over the past nine years, and the development is ongoing.…
Somatic embryogenesis in immature cotyledons of Manchurian ash (Fraxinus mandshurica Rupr.)
USDA-ARS?s Scientific Manuscript database
Somatic embryogenesis was obtained from immature cotyledon explants that were cultured on half-strength Murashige and Skoog (MS) salts and vitamins with 5.4 uM naphthaleneacetic acid (NAA) and 0.2 uM thidiazuron (TDZ) plus a 4x4 factorial combination of 0,9.8, 34.6, or 49.2 uM indole-3-butyric acid ...
VizieR Online Data Catalog: Young clumps embedded in IRDC (Traficante+, 2015)
NASA Astrophysics Data System (ADS)
Traficante, A.; Fuller, G. A.; Peretto, N.; Pineda, J. E.; Molinari, S.
2015-06-01
Photometric parameters for 667 starless clumps (sources identified at 160um with a counterpart at 250 and 350um) and 1056 protostellar clumps (sources identified at 160um with a counterpart at 70, 250 and 350um). Photometric parameters obtained with Hyper photometry code (2015A&A...574A.119T). The photometry is corrected for aperture and colour corrections. The parameter list is the standard Hyper output (see description below). SED fit parameters for 650 starless clumps and 1034 protostellar clumps (all clumps with good SED fitting: Chi2<10, Temperature<40K. See the paper for details) (4 data files).
VizieR Online Data Catalog: Draco nebula Herschel 250um map (Miville-Deschenes+, 2017)
NASA Astrophysics Data System (ADS)
Miville-Deschenes, M.-A.; Salome, Q.; Martin, P. G.; Joncas, G.; Blagrave, K.; Dassas, K.; Abergel, A.; Beelen, A.; Boulanger, F.; Lagache, G.; Lockman, F. J.; Marshall, D. J.
2017-03-01
Draco was observed with Herschel PACS (110 and 170um) and SPIRE (250, 350 and 500um) as part of the open-time program "First steps toward star formation: unveiling the atomic to molecular transition in the diffuse interstellar medium" (P.I. M-A Miville-Deschenes). A field of 3.85x3.85 was observed in parallel mode. Unfortunately, an error occurred during the acquisition of the PACS data making them unusable. Therefore, the results presented here are solely based on SPIRE data, especially the 250um map that has the highest angular resolution. (2 data files).
NASA Astrophysics Data System (ADS)
Soos, J. I.; Rosemeier, R. G.
1989-02-01
The edge of a transmission window for a GaAs Bragg cell starts about lum, which allows this material to be used for infrared fiber-optic applications, especially at 1.3um and 1.5um. The single crystal of GaAs is acoustically anisotropic and has the highest figure of merit, M2, along <111> direction for a longitudinal mode sound wave. Recently, Brimrose has designed and fabricated an acousto-optic modulator from GaAs operating at a carrier frequency of 2.3 GHz with a diffraction efficiency of 4%/RF watt.
VizieR Online Data Catalog: LRLL54361 protostar Herschel/PACS fluxes (Balog+, 2014)
NASA Astrophysics Data System (ADS)
Balog, Z.; Muzerolle, J.; Flaherty, K.; Detre, O. H.; Bouwmann, J.; Furlan, E.; Gutermuth, R.; Juhasz, A.; Bally, J.; Nielbock, M.; Klaas, U.; Krause, O.; Henning, T.; Marton, G.
2017-03-01
We observed a 14'x14' area in IC348 with the Photodetector Array Camera and Spectrometer (PACS; Poglitsch et al. 2010A&A...518L...2P) Herschel Space Observatory (Pilbratt et al. 2010A&A...518L...1P) simultaneously at 70 and 160um 24 times in scan map mode. An additional five epoch were observed during a later pulse phase of LRLL54361 in all three PACS photometer bands. The PACS spectrograph consists of a 5x5 array of 9.4" x 9.4" spatial pixels (hereafter referred to as spaxels) covering the spectral range from 52-210 um with λ/δλ ~1000-3000. Spectra were obtained in two spectral orders simultaneously, with the second order ranging from 51 to 105um and the first order from 102 to 210um. The spatial resolution of PACS-S ranges from ~9'' at 50um to ~18'' at 210um. Our target was observed in the standard range-scan spectroscopy mode with a grating step size corresponding to Nyquist sampling (see further Poglitsch et al. 2010A&A...518L...2P). (1 data file).
[Estimation of uncertainty of measurement in clinical biochemistry].
Enea, Maria; Hristodorescu, Cristina; Schiriac, Corina; Morariu, Dana; Mutiu, Tr; Dumitriu, Irina; Gurzu, B
2009-01-01
The uncertainty of measurement (UM) or measurement uncertainty is known as the parameter associated with the result of a measurement. Repeated measurements usually reveal slightly different results for the same analyte, sometimes a little higher, sometimes a little lower, because the results of a measurement are depending not only by the analyte itself, but also, by a number of error factors that could give doubts about the estimate. The uncertainty of the measurement represent the quantitative, mathematically expression of this doubt. UM is a range of measured values which is probably to enclose the true value of the measured. Calculation of UM for all types of laboratories is regularized by the ISO Guide to the Expression of Uncertainty in Measurement (abbreviated GUM) and the SR ENV 13005 : 2003 (both recognized by European Accreditation). Even if the GUM rules about UM estimation are very strictly, the offering of the result together with UM will increase the confidence of customers (patients or physicians). In this study the authors are presenting the possibilities of UM assessing in labs from our country by using the data obtained in the procedures of methods validation, during the internal and external quality control.
VizieR Online Data Catalog: Spectrophotometric distances of HII regions (Moises+, 2011)
NASA Astrophysics Data System (ADS)
Moises, A. P.; Damineli, A.; Figueredo, E.; Blum, R. D.; Conti, P. S.; Barbosa, C. L.
2011-11-01
The J-band (λ1.28um, δλ=0.3um), H-band (λ1.63um, δλ=0.3um) and Ks-band (λ2.19um, δλ=0.4um) images were obtained on the nights of 1999 May 1, 4 and 20, 2000 May 19 and 21 and 2001 July 10 and 12, at the Cerro Tololo Inter-American Observatory (CTIO) 4-m Blanco telescope, using the facility's infrared imager OSIRIS, which has a field of view (FOV) of 93x93arcsec2 and a pixel scale of 0.161arcsec/pixel. On the nights of 2005 Jult 3-6 and 11 and 2006 June 3-7, we obtained images using the facility's infrared imager ISPI (with a FOV of 10.25x10.25arcmin2 and a pixel scale of 0.3arcsec/pix), also at the 4-m Blanco telescope. Also, on the nights of 1998 August 28 and 29, we obtained images on the CTIO 4-m telescope using the facility's infrared imager CIRIM (with a FOV of 102x102arcsec2 and a pixel scale of 0.40arcsec/pix). (3 data files).
Unconsummated marriage: can it still be considered a consequence of vaginismus?
Michetti, P M; Silvaggi, M; Fabrizi, A; Tartaglia, N; Rossi, R; Simonelli, C
2014-01-01
Unconsummated marriage (UM) is the failure to perform successful sexual intercourse at the beginning of the marriage. Vaginismus has been traditionally reported as the leading cause. ED is also a leading cause for UM. This appears to be a significant problem in the conservative middle-Eastern societies and in the developing countries, where couples are strongly prevented by religious rules and cultural taboos from sexual experiences before wedding. One could think that according to major sexual freedom and information, in Western countries UM is now disappearing, but the number of observed cases by the authors in 2008-2012 was relevant. The aim of this study is to compare the literature data from non-Western countries with the features of UM in Western ones, focusing on cases observed by the authors, and to verify whether the etiology of UM proposed in the '70s is still relevant, outlining any changes that occur in current reality. In our series, traditional appearance of UM is no more effective, while the role of man is undervalued, because of his frailty, lack of self-confidence and ignorance, expressing a social and cultural change of man's role in the couple.
Yan, Fengxia; Liao, Rifang; Farhan, Mohd; Wang, Tinghuai; Chen, Jiashu; Wang, Zhong; Little, Peter J; Zheng, Wenhua
2016-12-01
Uveal melanoma (UM) is the most common primary intraocular malignant tumor of adults. It has high mortality rate due to liver metastasis. However, the epidemiology and pathogenesis of liver metastasis in UM are not elucidated and there is no effective therapy available for preventing the development of this disease. IGF-1 is a growth factor involved in cell proliferation, malignant transformation and inhibition of apoptosis. In previous report, IGF-1 receptor was found to be highly expressed in UM and this was related to tumor prognosis. FoxO3a is a Forkhead box O (FOXO) transcription factor and a downstream target of the IGF-1R/PI3K/Akt pathway involved in a number of physiological and pathological processes including cancer. However, the role of FoxO3a in UM is unknown. In the present study, we investigated fundamental mechanisms in the growth, migration and invasion of UM and the involvement of FoxO3a. IGF-1 increased the cell viability, invasion, migration and S-G2/M cell cycle phase accumulation of UM cells. Western blot analysis showed that IGF-1 led to activation of Akt and concomitant phosphorylation of FoxO3a. FoxO3a phosphorylation was associated with its translocation into the cytoplasm from the nucleus and its functional inhibition led to the inhibition of expression of Bim and p27, but an increase in the expression of Cyclin D1. The effects of IGF-1 on UM cells were reversed by LY294002 (a PI3K inhibitor) or Akt siRNA, and the overexpression of FoxO3a also attenuated basal invasion and migration of UM. Taken all together, these results suggest that inhibition of FoxO3a by IGF-1 via the PI3K/Akt pathway has an important role in IGF-1 induced proliferation and invasion of UM cells. These findings also support FoxO3a and IGF signaling may represent a valid target for investigating the development of new strategies for the treatment and prevention of the pathology of UM. Copyright © 2016. Published by Elsevier Masson SAS.
Ford/BASF/UM Activities in Support of the Hydrogen Storage Engineering Center of Excellence
DOE Office of Scientific and Technical Information (OSTI.GOV)
Veenstra, Mike; Purewal, Justin; Xu, Chunchuan
Widespread adoption of hydrogen as a vehicular fuel depends critically on the development of low-cost, on-board hydrogen storage technologies capable of achieving high energy densities and fast kinetics for hydrogen uptake and release. As present-day technologies -- which rely on physical storage methods such as compressed hydrogen -- are incapable of attaining established Department of Energy (DOE) targets, development of materials-based approaches for storing hydrogen have garnered increasing attention. Material-based storage technologies have potential to store hydrogen beyond twice the density of liquid hydrogen. To hasten development of these ‘hydride’ materials, the DOE previously established three centers of excellence formore » materials storage R&D associated with the key classes of materials: metal hydrides, chemical hydrogen, and adsorbents. While these centers made progress in identifying new storage materials, the challenges associated with the engineering of the system around a candidate storage material are in need of further advancement. In 2009 the DOE established the Hydrogen Storage Engineering Center of Excellence with the objective of developing innovative engineering concepts for materials-based hydrogen storage systems. As a partner in the Hydrogen Storage Engineering Center of Excellence, the Ford-UM-BASF team conducted a multi-faceted research program that addresses key engineering challenges associated with the development of materials-based hydrogen storage systems. First, we developed a novel framework that allowed for a material-based hydrogen storage system to be modeled and operated within a virtual fuel cell vehicle. This effort resulted in the ability to assess dynamic operating parameters and interactions between the storage system and fuel cell power plant, including the evaluation of performance throughout various drive cycles. Second, we engaged in cost modeling of various incarnations of the storage systems. This analysis revealed cost gaps and opportunities that identified a storage system that was lower cost than a 700 bar compressed system. Finally, we led the HSECoE efforts devoted to characterizing and enhancing metal organic framework (MOF) storage materials. This report serves as a final documentation of the Ford-UM-BASF project contributions to the HSECoE during the 6-year timeframe of the Center. The activities of the HSECoE have impacted the broader goals of the DOE-EERE and USDRIVE, leading to improved understanding in the engineering of materials-based hydrogen storage systems. This knowledge is a prerequisite to the development of a commercially-viable hydrogen storage system.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Petrun`kin, S.P.; Garavina, E.V.; Trostin, V.N.
1995-02-01
A container (cell) and a temperature-control system have been designed enabling one to carry out x-ray diffraction study of liquid samples both at a fixed temperature and within a certain temperature range using a commercial DRON-UMl x-ray diffractometer. Special features of the cell and the materials used for it allow one to study both chemically inert and corrosive liquids.
Benchmarking the Economic Impact and Effectiveness of University Technology Transfer in Maryland.
ERIC Educational Resources Information Center
Clinch, Richard
This study examined university technology transfer in Maryland in terms of three issues: (1) the economic impact of university technology transfer; (2) a comparison of the technology transfer effort of University of Maryland System (UMS) institutions with other regional and "best practice" institutions; and (3) the technology transfer…
Association of proteomics changes with Al-sensitive root zones in switchgrass
USDA-ARS?s Scientific Manuscript database
In this paper, we report on aluminum (Al)-induced root proteomic changes in switchgrass. After growth in a hydroponic culture system supplemented with 400 uM of Al, plants began to show signs of physiological stress such as a reduction in photosynthetic rate. At this time, the basal 2-cmlong root ti...
Engine Inlet Anti-Icing System Evaluation Procedure
1980-01-01
Content: Approximately 0.5 to 2.0 g/m3 Median Droplet Size: 11 to 20 Um Airspeed capability with the TFE731 nacelle installed was approximately 240 KTAS...employed for icing tests was adapted from a full-scale nacelle for the Garret-AiResearch Corporation TFE731 -2 turbofan engine. Modification to the nacelle
Systemic Arterial Hypertension in Patients Exposed to Cesium-137 in Goiânia-GO: Prevalence Study.
Rodrigues, José Victor Rabelo; Pinto, Murillo Macêdo; Figueredo, Roberto Miller Pires; Lima, Helen de; Souto, Rafael; Sacchetim, Sylvana de Castro
2017-01-01
Systemic Arterial Hypertension (SAH) in the Brazilian population, in populations not exposed to Césio-137, presents a prevalence of 28% nationwide. However, in the group of radioactivity victims, these values are unknown. To analyze the prevalence of hypertension in patients exposed to Cesium-137 in Goiânia, enrolled in the Sistema de Monitoramento dos Radioacidentados (SISRAD) (Radioactivtity Victims Monitoring System) of the Centro de Assistência aos Radioacidentados (C.A.R.A) (Assistence Center for Radioactivity Victims). This is a descriptive, observational cross-sectional epidemiological study carried out in Goiânia-Goiás, from August 2013 to October 2014, with a group of patients enrolled in the Sistema de Monitoramento dos Radioacidentados (SISRAD) of the Centro de Assistência a Radioacidentados (C.A.R.A.). A total of 102 radioactive patients were divided into two groups: group 1 with 40 and group 2 with 62 participants. A field survey was conducted with a closed and semi-structured questionnaire in which the following contexts were addressed: sociodemographic profile, life habits and personal background. A database was created using the Google Forms application from the Google Web technologies company. The duly collected and stored data were imported and analyzed in the statistical software SPSS, version 21. The prevalence of SAH reached a total of 25% (12 individuals) of the 48 interviewees, 50% of women (24) and 50% of men (24), of which 22.9% (11) of the radioactivity victims revealed to be smokers. The prevalence of SAH in the radioactivity victims population is similar to that of the population in general. A Hipertensão Arterial Sistêmica (HAS) na população brasileira, em populações não expostas ao Césio-137, apresenta prevalência de 28% em âmbito nacional. Porém, no grupo de radioacidentados, esses valores são desconhecidos. Analisar a prevalência da HAS em pacientes expostos ao Césio-137 ocorrido em Goiânia, cadastrados no Sistema de Monitoramento dos Radioacidentados (SISRAD) do Centro de Assistência aos Radioacidentados (C.A.R.A). Estudo epidemiológico do tipo descritivo, observacional de caráter transversal realizado em Goiânia-Goiás, no período de agosto de 2013 a outubro de 2014, com grupo de pacientes cadastrados no Sistema de Monitoramento dos Radioacidentados (SISRAD) do Centro de Assistência aos Radioacidentados (C.A.R.A). Participaram da pesquisa 48 radioacidentados de um total de 102 que foram subdivididos em dois grupos: grupo 1 com 40 e o grupo 2 com 62 participantes. Realizou-se uma pesquisa de campo com questionário fechado e semi-estruturado em que foram abordados os seguintes contextos: perfil sociodemográfico, hábitos de vida e antecedentes pessoais. Criou-se um banco de dados utilizando-se o aplicativo Google Forms, da empresa de tecnologias na Web Google. Os dados devidamente coletados e armazenados foram importados e analisados no software estatístico SPSS, versão 21. Dos 48 entrevistados a prevalência de HAS atingiu um total 25% deles (12 indivíduos), sendo 50% de mulheres (24) e 50% de homens (24), dentre estes, 22,9% (11) dos radioacidentados revelaram ser tabagistas. A prevalência de HAS na população de radioacidentados se manifesta de forma semelhante ao da população em geral.
Undermethylated DNA as a source of microsatellites from a conifer genome.
Zhou, Y; Bui, T; Auckland, L D; Williams, C G
2002-02-01
Developing microsatellites from the large, highly duplicated conifer genome requires special tools. To improve the efficiency of developing Pinus taeda L. microsatellites, undermethylated (UM) DNA fragments were used to construct a microsatellite-enriched copy library. A methylation-sensitive restriction enzyme, McrBC, was used to enrich for UM DNA before library construction. Digested DNA fragments larger than 9 kb were then excised and digested with RsaI and used to construct nine dinucleotide and trinucleotide libraries. A total of 1016 microsatellite-positive clones were detected among 11 904 clones and 620 of these were unique. Of 245 primer sets that produced a PCR product, 113 could be developed as UM microsatellite markers and 70 were polymorphic. Inheritance and marker informativeness were tested for a random sample of 36 polymorphic markers using a three-generation outbred pedigree. Thirty-one microsatellites (86%) had single-locus inheritance despite the highly duplicated nature of the P. taeda genome. Nineteen UM microsatellites had highly informative intercross mating type configurations. Allele number and frequency were estimated for eleven UM microsatellites using a population survey. Allele numbers for these UM microsatellites ranged from 3 to 12 with an average of 5.7 alleles/locus. Frequencies for the 63 alleles were mostly in the low-common range; only 14 of the 63 were in the rare allele (q < 0.05) class. Enriching for UM DNA was an efficient method for developing polymorphic microsatellites from a large plant genome.
Downscaling Alkaline Phosphatase Activity in a Subtropical Reservoir
NASA Astrophysics Data System (ADS)
Tseng, Y.
2011-12-01
This research was conducted by downscaling study to understand phosphorus (P)-deficient status of different plankton and the role of alkaline phosphatase activity (APA) in subtropical Feitsui Reservoir. Results from field survey showed that bulk APA (1.6~95.2 nM h-1) was widely observed in the epilimnion (0~20 m) with an apparent seasonal variations, suggesting that plankton in the system were subjected to P-deficient seasonally. Mixed layer depth (an index of phosphate availability) is the major factor influencing the variation of bulk APA and specific APA (124~1,253 nmol mg C-1 h-1), based on multiple linear regression analysis. Size-fractionated APA assays showed that picoplankton (size 0.2~3 um) contributed most of the bulk APA in the system. In addition, single-cell APA detected by enzyme-labeled fluorescence (ELF) assay indicated that heterotrophic bacteria are the major contributors of APA. Thus, we can infer that bacteria play an important role in accelerating P-cycle within P-deficient systems. Light/nutrient manipulation bioassays showed that bacterial growth was directly controlled by phosphate, while picocyanobacterial growth is controlled by light and can out-compete bacteria under P-limited condition with the aid of light. Further analysis revealed that the strength of summer typhoon is a factor responsible for the inter-annual variability of bulk and specific APA. APA study demonstrated the episodic events (e.g. strong typhoon and extreme precipitation) had significant influence on APA variability in sub-tropical to tropical aquatic ecosystems. Hence, the results herein will allow future studies on monitoring typhoon disturbance (intensity and frequency) as well as the APA of plankton during summer-to-autumn in subtropical systems.
Monitoring system and methods for a distributed and recoverable digital control system
NASA Technical Reports Server (NTRS)
Stange, Kent (Inventor); Hess, Richard (Inventor); Kelley, Gerald B (Inventor); Rogers, Randy (Inventor)
2010-01-01
A monitoring system and methods are provided for a distributed and recoverable digital control system. The monitoring system generally comprises two independent monitoring planes within the control system. The first monitoring plane is internal to the computing units in the control system, and the second monitoring plane is external to the computing units. The internal first monitoring plane includes two in-line monitors. The first internal monitor is a self-checking, lock-step-processing monitor with integrated rapid recovery capability. The second internal monitor includes one or more reasonableness monitors, which compare actual effector position with commanded effector position. The external second monitor plane includes two monitors. The first external monitor includes a pre-recovery computing monitor, and the second external monitor includes a post recovery computing monitor. Various methods for implementing the monitoring functions are also disclosed.
VizieR Online Data Catalog: UKIDSS-DR8 LAS, GCS and DXS Surveys (Lawrence+ 2012)
NASA Astrophysics Data System (ADS)
Lawrence, A.; Warren, S. J.; Almaini, O.; Edge, A. C.; Hambly, N. C.; Jameson, R. F.; Lucas, P.; Casali, M.; Adamson, A.; Dye, S.; Emerson, J. P.; Foucaud, S.; Hewett, P.; Hirst, P.; Hodgkin, S. T.; Irwin, M. J.; Lodieu, N.; McMahon, R. G.; Simpson, C.; Smail, I.; Mortlock, D.; Folger, M.
2012-03-01
The UKIRT Infrared Deep Sky Survey (UKIDSS) is a large-scale near-IR survey which aim is to cover 7500 square degrees of the Northern sky. The survey is carried out using the Wide Field Camera (WFCAM), with a field of view of 0.21 square degrees, mounted on the 3.8m United Kingdom Infra-red Telescope (UKIRT) in Hawaii. The project comprises five surveys (LAS, GCS, DXS, GPS and UDS). The Large Area Survey (LAS) covers an area of 4000 square degrees in high Galactic latitudes (extragalactic) in the four bands Y(1.0um) J(1.2um) H(1.6um) and K(2.2um) to a depth of K=18.4. The Galactic Clusters Survey (GCS) aims to survey ten large open star clusters and star formation associations, covering a total of 1067 square degrees in the five bands Z (0.9um), Y(1.0um) J(1.2um) H(1.6um) and K(2.2um), plus a second pass in K for proper motions, to a depth of Z=20.4, Y=20.3, J=19.5, H=18.6, K=18.6. The Deep Extragalactic Survey (DXS) aims to map 35 square degrees of sky to a 5-σ point-source sensitivity of J=22.3 and K=20.8 in four carefully selected, multi-wavelength survey areas. The central regions of each field will also be mapped to H=21.8. The primary aim of the survey is to produce a photometric galaxy sample at a redshift of 1-2, within a volume comparable to that of the SDSS, selected in the same passband (rest frame optical). Details of the surveys can be found in the in the paper by Lawrence et al. (2007MNRAS.379.1599L), and at the UKIDSS Surveys site (http://www.ukidss.org/surveys/surveys.html). The data described here represent a subset of the UKIDSS data, limited to the public data and most representative columns. In the "Byte-by-byte Description" below the original names of the columns are given as bracketed names. (3 data files).
NASA Astrophysics Data System (ADS)
Qiang, Liangliang
A miniature wireless implantable electrochemical glucose system for continuous glucose monitoring with good selectivity, sensitivity, linearity and long term stability was developed. First, highly sensitive, long-term stable and reusable planar H2O2 microelectrodes have been fabricated by microlithography. These electrodes composed of a 300 nm Pt black layer situated on a 5 um thick Au layer, provide effective protection to the underlying chromium adhesion layer. Using repeated cyclic voltammetric sweeps in flowing buffer solution, highly sensitive Pt black working electrodes were realized with five-decade linear dynamic range and low detection limit (10 nM) for H2O2 at low oxidation potentials. Second, a highly sensitive, low cost and flexible microwire biosensor was described using 25-mum thick gold wire as working electrode together with 125-mum thick Pt/Ir and Ag wires as counter and reference electrode, embedded within a PDMS-filled polyethylene tube. Surface area and activity of sensor was enhanced by converting gold electrode to nanoporous configuration followed by electrodeposition of platinum black. Glucose oxidase based biosensors by electrodeposition of poly(o-phenylenediamine) and glucose oxidase on the working electrode, displayed a higher glucose sensitivity (1.2 mA mM-1 cm-2) than highest literature reported. In addition it exhibits wide detection range (up to 20 mM) and selectivity (>95%). Third, novel miniaturized and flexible microelectrode arrays with 8 of 25 mum electrodes displayed the much needed 3D diffusion profiles similar to a single 25 mum microelectrode, but with one order increase in current levels. These microelectrode arrays displayed a H2O2 sensitivity of 13 mA mM-1 cm-2, a wide dynamic range of 100 nM to 10 mM, limit of detection of 10 nM. These microwire based edge plane microsensors incorporated flexibility, miniaturization and low operation potential are an promising approach for continuous in vivo metabolic monitoring. Fourth, homemade miniature wireless potentisotat was fabricated based on low power consumption integrated circuits and surface mount parts. The miniature wireless potentisotat with up to two week life-time for continuous glucose sensing has a size less than 9x22x10 mm and weight ˜3.4 grams. Primary in vivo experiment showed homemade system has the exactly same respond and trend as commercial glucose meter.
Study on extrusion process of SiC ceramic matrix
NASA Astrophysics Data System (ADS)
Dai, Xiao-Yuan; Shen, Fan; Ji, Jia-You; Wang, Shu-Ling; Xu, Man
2017-11-01
In this thesis, the extrusion process of SiC ceramic matrix has been systematically studied.The effect of different cellulose content on the flexural strength and pore size distribution of SiC matrix was discussed.Reselts show that with the increase of cellulose content, the flexural strength decreased.The pore size distribution in the sample was 1um-4um, and the 1um-2um concentration was more concentrated. It is found that the cellulose content has little effect on the pore size distribution.When the cellulose content is 7%, the flexural strength of the sample is 40.9Mpa. At this time, the mechanical properties of the sample are the strongest.
NASA Technical Reports Server (NTRS)
Cook, William
1999-01-01
Measuring and understanding the distribution of ozone through the lower levels of Earth's atmosphere are high priorities in global change and climate research. Of particular interest now is the global distribution of ozone in the upper troposphere and lower stratosphere. Global coverage of the stratospheric ozone is feasible only via remote sensing instruments on a space-based platform. And though extensive monitoring tropospheric ozone is possible using instruments flown aboard conventional aircraft, a space-based system would be significantly less costly and provide information over a much broader area and produce more uniform coverage. Here we describe the prototype of an instrument being developed to monitor, from an orbiting spacecraft, the ozone found in Earth's upper troposphere and lower stratosphere. Our new spectrometer is an infrared Fabry-Perot interferometer which uses two synchrounously tuned etalons: a high resolution narrow band device and a lower resolution broader band filtering etalon. The prototype is a scanning device making use of nearly collimated input radiation and a single element detector. As presently configured, it is capable of providing a resolution better than 0.07/cm with a spectral band width approximately 5/cm wide and centered at 1054.7/cm. For the future space-based emission device a modification of the the prototype was to be made to employ innovative circle-to-line detector optics, those developed or in development at UM/SPRL, and a focal plane array detector. These enhancements would enable a simultaneous recording of the entire spectral range of interest, but with simple detection electronics and a significant gain in signal-to-noise over that of the scanning version.
NASA Astrophysics Data System (ADS)
Silva, Jaime Pedro Oliveira da
A presente tese centrou-se no estudo da resposta da constante dieletrica e condutividade eletrica em materiais compositos nos quais o reforco tinha uma elevada proporcao entre comprimento e diametro. O objeto de estudo foi o efeito de um reforco com uma elevada razao entre comprimento e diametro, concentracao e orientacao na resposta eletrica e dieletrica de um composito. Estes compositos tem uma grande importancia no desenvolvimento de materiais para sensores e atuadores. Num primeiro momento da dissertacao, explorou-se a resposta da constante dieletrica de um composito constituido por nanotubos de carbono como reforco e uma matriz polimerica. Verificou-se que um aumento da razao entre comprimento e diametro do reforco tem o efeito de aumentar a constante dieletrica do composito para uma igual fracao volumetrica de reforco. Constatou-se tambem que materiais na fase nematica demonstram uma constante dieletrica mais baixa quando comparados com materiais onde o reforco esta distribuido aleatoriamente. Ficou ainda demonstrado nesta dissertacao que materiais na fase nematica com razoes entre o comprimento e diametro diferentes a constante dieletrica segue uma lei de potencia. Numa segunda fase do trabalho, foi explorada a condutividade de nanocompositos polimericos reforcados com nanotubos de carbono, atraves de um modelo baseado em cilindros impenetraveis. Ficou demonstrado que o modelo e apropriado para descrever a condutividade eletrica de um nanocomposito polimerico reforcado com nanotubos. As simulacoes desenvolvidas demonstram que, aumentando a razao entre o comprimento e o diametro dos nanotubos de carbono, aumenta a condutividade eletrica do nanocomposito. No entanto, verifica-se que aumentando a anisotropia diminui a condutividade, sendo este efeito mais evidente para fracoes volumetricas maiores. Nesta dissertacao comprovou-se ainda que uma microestrutura gerada por um algoritmo de empacotamento sequencial pode ser descrita por um grafo aleatorio e que a condutividade num composito reforcado com nanofibras de carbono pode ser descrito por uma rede de Bethe. Atraves do uso da teoria das redes complexas, chegou-se a uma expressao para o limite de percolacao e, do mesmo modo, demonstrou-se que “hopping” entre fibras adjacentes resulta numa expressao que corresponde a um regime de desordem fraca. No trabalho desenvolvido tambem foi calculado os expoentes criticos, atraves da teoria das redes, para um sistema 3D composto por cilindros impenetraveis com uma interacao de curto alcance, demonstrando que os expoentes criticos estao relacionados por uma relacao de hiperescala comum para 3D e nao pertencem a mesma classe de universalidade como a percolacao numa rede. A aplicacao do modelo desenvolvido a compositos de epoxy reforcada, com diferentes metodos de dispersao de nanofibras de carbono, revelou que os metodos de dispersao usados para preparar os compositos tem uma forte influencia nas propriedades eletricas que podem ser capturadas pelo modelo. Neste contexto, ficou ainda demonstrado que a condutividade eletrica pode ser descrita por um regime de desordem fraca, isto ´e, um regime onde todas as conexoes fibra-fibra participam na condutividade do composito. O modelo desenvolvido foi aplicado igualmente a compositos de poly (vinylidene fluoride) reforcado com nanotubos de carbono com diferentes tratamentos de termicos de oxidacao. Verificou-se que os tratamentos de superficie aumentam o limite de percolacao e diminuem a condutividade. Nesta dissertacao provamos ainda que a condutividade do composito pode ser atribuida a um mecanismo de “hopping”, fortemente afetado pelos tratamentos de superficie dos reforcos.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Obata, T.; Yamamura, H.I.
1988-01-01
The effects of triazolobenzodiazepines of GABA-stimulated /sup 36/Cl/sup -/ uptake by membrane vesicles from rat cerebral cortex were examined. Triazolam and alprazolam showed a significant enhancement of GABA-stimulated /sup 36/Cl/sup -/ uptake at 0.01-10 uM. On the other hand, adinazolam showed a small enhancement at 0.1-1 uM followed by a significant inhibition of GABA-stimulated /sup 36/Cl/sup -/ uptake at 100 uM. The enhancement of GABA-stimulated /sup 36/Cl/sup -/ uptake by 1 uM alprazolam was antagonized by Ro15-1788, a benzodiazepine antagonist, but the inhibition of this response by 30 uM adinazolam was not antagonized by Ro15-1788. These results indicate that triazolobenzodiazepinesmore » enhanced GABA-stimulated /sup 36/Cl/sup -/ uptake through benzodiazepine receptors. High concentrations of adinazolam inhibit GABA-stimulated /sup 36/Cl/sup -/ uptake which may be due to the direct blockade of GABA-gated chloride channel. 23 references, 4 figures.« less
Selumetinib-based therapy in uveal melanoma patient-derived xenografts
Decaudin, Didier; El Botty, Rania; Diallo, Béré; Massonnet, Gerald; Fleury, Justine; Naguez, Adnan; Raymondie, Chloé; Davies, Emma; Smith, Aaron; Wilson, Joanne; Howes, Colin; Smith, Paul D.; Cassoux, Nathalie; Piperno-Neumann, Sophie; Roman-Roman, Sergio; Némati, Fariba
2018-01-01
The prognosis of metastatic uveal melanoma (UM) is among the worst of all human cancers. The identification of near-ubiquitous GNAQ/GNA11 mutations and the activation of MAPK signaling in UM have raised hopes of more effective, targeted therapies, based on MEK inhibition, for example. We evaluated the potential of drug combinations to increase the efficacy of the MEK inhibitor selumetinib (AZD6244, ARRY-142886), in UM cell lines and Patient-Derived Xenografts. We first evaluated the combination of selumetinib and DTIC. We found that DTIC did not improve the in vitro or in vivo antitumor efficacy of selumetinib, consistent with the outcome of the SUMIT clinical trial assessing the efficacy of this combination in UM. We then tested additional selumetinib combinations with the chemotherapy agent docetaxel, the ERK inhibitor AZ6197, and the mTORC1/2 inhibitor, vistusertib (AZD2014). Combinations of selumetinib with ERK and mTORC1/2 inhibitors appeared to be the most effective in UM PDX models. PMID:29774094
Immunostaining, dehydration, and clearing of mouse embryos for ultramicroscopy.
Becker, Klaus; Jährling, Nina; Saghafi, Saiedeh; Dodt, Hans-Ulrich
2013-08-01
This protocol describes the preparation of mouse embryos for ultramicroscopy (UM), a powerful imaging technique that achieves precise and accurate three-dimensional (3D) reconstructions of intact macroscopic specimens with micrometer resolution. In UM, a specimen in the size range of ∼1-15 mm is illuminated perpendicular to the observation pathway by two thin counterpropagating sheets of laser light. In combination with fluorescein isothiocyanate (FITC) immunostaining, UM allows visualization of somatic motor and sensorial nerve fibers in whole mouse embryos. Even the fine branches of the sensomotoric fibers can be visualized over a distance of up to several millimeters. In this protocol, mouse embryos are fixed and immunostained in preparation for UM. Because UM requires the excitation light sheet to travel throughout the entire horizontal width of the specimen, specimens usually have to be rendered transparent before microscope inspection. Here, the embryos are dehydrated in ethanol and then cleared in a solution of benzyl alcohol and benzyl benzoate.
The mental health of unaccompanied refugee minors on arrival in the host country.
Vervliet, Marianne; Meyer Demott, Melinda A; Jakobsen, Marianne; Broekaert, Eric; Heir, Trond; Derluyn, Ilse
2014-02-01
Despite increasing numbers of unaccompanied refugee minors (UM) in Europe and heightened concerns for this group, research on their mental health has seldom included the factor "time since arrival." As a result, our knowledge of the mental health statuses of UM at specific points in time and over periods in their resettlement trajectories in European host countries is limited. This study therefore examined the mental health of UM shortly after their arrival in Norway (n = 204) and Belgium (n = 103) through the use of self-report questionnaires (HSCL-37A, SLE, RATS, HTQ). High prevalence scores of anxiety, depression and posttraumatic stress disorder (PTSD) symptoms were found. In addition, particular associations were found with the number of traumatic events the UM reported. The results indicate that all UM have high support needs on arrival in the host country. Longitudinal studies following up patterns of continuity and change in their mental health during their trajectories in the host country are necessary. © 2014 Scandinavian Psychological Associations and John Wiley & Sons Ltd.
NASA Technical Reports Server (NTRS)
Mattox, D. M.
1981-01-01
Surface tension gradient in melt forces gas bubbles to surface, increasing glass strength and transparency. Conventional chemical and buoyant fining are extremely slow in viscous glasses, but tension gradient method moves 250 um bubbles as rapidly as 30 um/s. Heat required for high temperature part of melt is furnished by stationary electrical or natural-gas heater; induction and laser heating are also possible. Method has many applications in industry processes.
Patient population management: taking the leap from variance analysis to outcomes measurement.
Allen, K M
1998-01-01
Case managers today at BCHS have a somewhat different role than at the onset of the Collaborative Practice Model. They are seen throughout the organization as: Leaders/participants on cross-functional teams. Systems change agents. Integrating/merging with quality services and utilization management. Outcomes managers. One of the major cross-functional teams is in the process of designing a Care Coordinator role. These individuals will, as one of their functions, assume responsibility for daily patient care management activities. A variance tracking program has come into the Utilization Management (UM) department as part of a software package purchased to automate UM work activities. This variance program could potentially be used by the new care coordinators as the role develops. The case managers are beginning to use a Decision Support software, (Transition Systems Inc.) in the collection of data that is based on a cost accounting system and linked to clinical events. Other clinical outcomes data bases are now being used by the case manager to help with the collection and measurement of outcomes information. Hoshin planning will continue to be a framework for defining and setting the targets for clinical and financial improvements throughout the organization. Case managers will continue to be involved in many of these system-wide initiatives. In the words of Galileo, 1579, "You need to count what's countable, measure what's measurable, and what's not measurable, make measurable."
Filker, Phyllis J; Muckey, Erin Joy; Kelner, Steven M; Kodish-Stav, Jodi
2009-09-01
The Obama administration is seeking to increase access to and improve the efficiency of the health care system in the United States. One aspect of those efforts is a push towards the utilization of electronic health records (EHRs) by health care providers. Nova Southeastern University College of Dental Medicine (NSU-CDM) opened its doors in 1997 and began its evolution from paper charts to EHRs in 2006. AxiUm, a computer-run patient record and clinical management system, has become an integral part of the college's quality assurance program and its students' clinical education. Since the introduction of axiUm, the school has already noticed an increase in the quality of patient care due to improved oversight of patient management and the ability to more efficiently track treatment outcomes. Over time, the system will enable data collected by students providing care in the clinics to be quantified. Opposition to EHRs tends to stem primarily from the amount of time required for users to gain proficiency in the new technology, as well as from the initial cost to the provider. But there is no better place to begin this learning process regarding the importance and utilization of EHR systems than universities, where health professions students can acquire a comfort level with EHRs in an academic environment that they may then implement in their future practice.
Dopierala, Justyna; Damato, Bertil E; Lake, Sarah L; Taktak, Azzam F G; Coupland, Sarah E
2010-10-01
To determine intratumor genetic heterogeneity in uveal melanoma (UM) by multiplex ligation-dependent probe amplification (MLPA) in formalin-fixed, paraffin-embedded (FFPE) tumor tissues. DNA was extracted from whole tumor sections and from two to nine different areas microdissected from 32 FFPE UMs. Thirty-one loci on chromosomes 1, 3, 6, and 8 were tested with MLPA for copy number changes. The tumor was considered heterogeneous at a locus if (1) the difference in dosage quotients (DQs) of any two areas was 0.2 or more, and (2) the DQs of the areas belonged to different ranges. Comparison of MLPA data obtained from microdissected areas of the UMs showed heterogeneity in 1 to 26 examined loci in 24 (75%) tumors, with only 25% of the tumors being homogeneous. Intratumor heterogeneity of 3p12.2, 6p21.2, and 8q11.23 was most common, occurring in >30% of the UMs. Gains of chromosome 3 were observed in four UMs, with three of these tumors showing the highest degree of heterogeneity. Copy number variation was associated with differences in tumor cell type, but not with differences in tumor pigmentation or reactive inflammation. UMs with genetic heterogeneity across multiple sample sites showed equivocal MLPA results when the whole tumor section was examined. These results suggest that different clones dilute MLPA results. Heterogeneity of chromosomal abnormalities of chromosomes 1, 3, 6, and 8 is present in most UMs. This heterogeneity causes equivocal MLPA results. One random tumor sample may not be representative of the whole tumor and, therefore, may be insufficient for prognostic testing.
Genomic insight into pathogenicity of dematiaceous fungus Corynespora cassiicola
Looi, Hong Keat; Toh, Yue Fen; Yew, Su Mei; Na, Shiang Ling; Tan, Yung-Chie; Chong, Pei-Sin; Khoo, Jia-Shiun; Yee, Wai-Yan; Ng, Kee Peng
2017-01-01
Corynespora cassiicola is a common plant pathogen that causes leaf spot disease in a broad range of crop, and it heavily affect rubber trees in Malaysia (Hsueh, 2011; Nghia et al., 2008). The isolation of UM 591 from a patient’s contact lens indicates the pathogenic potential of this dematiaceous fungus in human. However, the underlying factors that contribute to the opportunistic cross-infection have not been fully studied. We employed genome sequencing and gene homology annotations in attempt to identify these factors in UM 591 using data obtained from publicly available bioinformatics databases. The assembly size of UM 591 genome is 41.8 Mbp, and a total of 13,531 (≥99 bp) genes have been predicted. UM 591 is enriched with genes that encode for glycoside hydrolases, carbohydrate esterases, auxiliary activity enzymes and cell wall degrading enzymes. Virulent genes comprising of CAZymes, peptidases, and hypervirulence-associated cutinases were found to be present in the fungal genome. Comparative analysis result shows that UM 591 possesses higher number of carbohydrate esterases family 10 (CE10) CAZymes compared to other species of fungi in this study, and these enzymes hydrolyses wide range of carbohydrate and non-carbohydrate substrates. Putative melanin, siderophore, ent-kaurene, and lycopene biosynthesis gene clusters are predicted, and these gene clusters denote that UM 591 are capable of protecting itself from the UV and chemical stresses, allowing it to adapt to different environment. Putative sterigmatocystin, HC-toxin, cercosporin, and gliotoxin biosynthesis gene cluster are predicted. This finding have highlighted the necrotrophic and invasive nature of UM 591. PMID:28149676
Measuring Broadband IR Irradiance in the Direct Solar Beam and Recent Developments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reda, Ibrahim; Andreas, Afshin; Dooraghi, Mike
2016-12-14
Solar and atmospheric science radiometers such as pyranometers, pyrheliometers, and photovoltaic cells are calibrated with traceability to a consensus reference which is maintained by Absolute Cavity Radiometers (ACRs). An ACR is an open cavity with no window, developed to measure the extended broadband spectrum of the terrestrial direct solar beam irradiance that extends beyond the ultraviolet and infrared bands; i.e. below 0.2 um and above 50 um, respectively. On the other hand, the pyranometers and pyrheliometers were developed to measure broadband shortwave irradiance from approximately 0.3 um to 3 um, while the present photovoltaic cells are limited to the spectralmore » range of approximately 0.3 um to 1 um. The broadband mismatch of ACR versus such radiometers causes discrepancy in radiometers' calibration methods that has not been discussed or addressed in the solar and atmospheric science literature. Pyrgeometers, which measure the atmospheric longwave irradiance, are also used for solar and atmospheric science applications and calibrated with traceability to a consensus reference, yet they are calibrated during nighttime only, because no consensus reference has been established for the daytime longwave irradiance. This poster describes a method to measure the broadband longwave irradiance in the terrestrial direct solar beam from 3 um to 50 um, as a first step that might be used to help develop calibration methods to address the mismatch between broadband ACR and shortwave radiometers, and the lack of a daytime reference for pyrgeometers. The described method is used to measure the irradiance from sunrise to sunset; the irradiance varied from approximately 1 Wm-2 to 16 Wm-2 with an estimated uncertainty of 1.5 Wm-2, for a solar zenith angle range from 80 degrees to 16 degrees, respectively. Recent development shows that there is greater than 1.1 percent bias in measuring shortwave solar irradiance.« less
Optical mechanisms for detection of lipid-rich atherosclerotic plaques by near-infrared spectroscopy
NASA Astrophysics Data System (ADS)
Hull, Edward L.; Gardner, Craig M.; Muller, James E.; Muller, Vianna J.; Salvato, Christopher V.; Lisauskas, Jennifer B.; Caplan, Jay D.
2008-02-01
InfraReDx has developed a spectroscopic cardiac catheter system capable of acquiring near-infrared (NIR) reflectance spectra from coronary arteries in vivo for identification of lipid-rich plaques of interest (LRP). The spectral data are analyzed with a chemometric model, producing a hyperspectral image (a chemogram) used to identify LRP in the interrogated region. In this paper, we describe a FT-IR microscopy system for measurement of the NIR scattering and absorption properties of healthy and diseased regions of human coronary arteries in small volumes (~10 μl). Scattering and absorption coefficients are obtained from sequential 140 um x 140 um regions of interest across the face of 500-micron thick, saline-irrigated fresh coronary artery sections. A customized FTIR microscope, measurement protocol, and inversion algorithm are used for optical property determination, and the system is calibrated using measurements of tissue-simulating phantoms having well-characterized optical properties. Tissue optical properties are co-registered with brightfield transmission images as well as with stained histologic thin sections (H&E, Movat Pentachrome, and Oil Red O) acquired from an immediately-adjacent section. The ultimate goal of these experiments is to establish a mechanistic link between the multivariate model predictions displayed on the InfraReDx chemogram and the light-tissue interactions that govern the measured NIR reflectance spectra.
Analysis and design of a high power laser adaptive phased array transmitter
NASA Technical Reports Server (NTRS)
Mevers, G. E.; Soohoo, J. F.; Winocur, J.; Massie, N. A.; Southwell, W. H.; Brandewie, R. A.; Hayes, C. L.
1977-01-01
The feasibility of delivering substantial quantities of optical power to a satellite in low earth orbit from a ground based high energy laser (HEL) coupled to an adaptive antenna was investigated. Diffraction effects, atmospheric transmission efficiency, adaptive compensation for atmospheric turbulence effects, including the servo bandwidth requirements for this correction, and the adaptive compensation for thermal blooming were examined. To evaluate possible HEL sources, atmospheric investigations were performed for the CO2, (C-12)(O-18)2 isotope, CO and DF wavelengths using output antenna locations of both sea level and mountain top. Results indicate that both excellent atmospheric and adaption efficiency can be obtained for mountain top operation with a micron isotope laser operating at 9.1 um, or a CO laser operating single line (P10) at about 5.0 (C-12)(O-18)2um, which was a close second in the evaluation. Four adaptive power transmitter system concepts were generated and evaluated, based on overall system efficiency, reliability, size and weight, advanced technology requirements and potential cost. A multiple source phased array was selected for detailed conceptual design. The system uses a unique adaption technique of phase locking independent laser oscillators which allows it to be both relatively inexpensive and most reliable with a predicted overall power transfer efficiency of 53%.
Made in Maine: A State Report Card on Public Higher Education
ERIC Educational Resources Information Center
Markley, Eric; Poliakoff, Michael
2011-01-01
Maine is blessed with universities that have records of significant achievement. The seven campuses of the University of Maine System (UMS) together educated over 23,000 students (full-time equivalent) during the past year. But for good reason, in recent years public confidence in higher education throughout the nation has fallen. Half of the…
Unmanned Maritime Systems Incremental Acquisition Approach
2016-12-01
We find that current UMS acquisitions are utilizing previous acquisition reforms, but could benefit from additional contractor peer competition and...peer review. Additional cost and schedule benefits could result from contractor competition during build processes in each incremental process. We...acquisitions are utilizing previous acquisition reforms, but could benefit from additional contractor peer competition and peer review. Additional
Cryogenic Target-Implosion Experiments on OMEGA
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harding, D.R.; Meyerhofer, D.D.; Sangster, T.C.
The University of Rochester’s Laboratory for Laser Energetics has been imploding thick cryogenic targets for six years. Improvements in the Cryogenic Target Handling System and the ability to accurately design laser pulse shapes that properly time shocks and minimize electron preheat, produced high fuel areal densities in deuterium cryogenic targets (202+/-7 mg/cm^2). The areal density was inferred from the energy loss of secondary protons in the fuel (D2) shell. Targets were driven on a low final adiabat (alpha = 2) employing techniques to radially grade the adiabat (the highest adiabat at the ablation surface). The ice layer meets the target-designmore » toughness specification for DT ice of 1-um rms (all modes), while D2 ice layers average 3.0-um-rms roughness. The implosion experiments and the improvements in the quality and understanding of cryogenic targets are presented.« less
A time-resolved image sensor for tubeless streak cameras
NASA Astrophysics Data System (ADS)
Yasutomi, Keita; Han, SangMan; Seo, Min-Woong; Takasawa, Taishi; Kagawa, Keiichiro; Kawahito, Shoji
2014-03-01
This paper presents a time-resolved CMOS image sensor with draining-only modulation (DOM) pixels for tube-less streak cameras. Although the conventional streak camera has high time resolution, the device requires high voltage and bulky system due to the structure with a vacuum tube. The proposed time-resolved imager with a simple optics realize a streak camera without any vacuum tubes. The proposed image sensor has DOM pixels, a delay-based pulse generator, and a readout circuitry. The delay-based pulse generator in combination with an in-pixel logic allows us to create and to provide a short gating clock to the pixel array. A prototype time-resolved CMOS image sensor with the proposed pixel is designed and implemented using 0.11um CMOS image sensor technology. The image array has 30(Vertical) x 128(Memory length) pixels with the pixel pitch of 22.4um. .
NASA Astrophysics Data System (ADS)
Simpson, R. A.; Davis, D. E.
1982-09-01
This paper describes techniques to detect submicron pattern defects on optical photomasks with an enhanced direct-write, electron-beam lithographic tool. EL-3 is a third generation, shaped spot, electron-beam lithography tool developed by IBM to fabricate semiconductor devices and masks. This tool is being upgraded to provide 100% inspection of optical photomasks for submicron pattern defects, which are subsequently repaired. Fixed-size overlapped spots are stepped over the mask patterns while a signal derived from the back-scattered electrons is monitored to detect pattern defects. Inspection does not require pattern recognition because the inspection scan patterns are derived from the original design data. The inspection spot is square and larger than the minimum defect to be detected, to improve throughput. A new registration technique provides the beam-to-pattern overlay required to locate submicron defects. The 'guard banding" of inspection shapes prevents mask and system tolerances from producing false alarms that would occur should the spots be mispositioned such that they only partially covered a shape being inspected. A rescanning technique eliminates noise-related false alarms and significantly improves throughput. Data is accumulated during inspection and processed offline, as required for defect repair. EL-3 will detect 0.5 um pattern defects at throughputs compatible with mask manufacturing.
NASA Astrophysics Data System (ADS)
McNerney, Gregory Paul
Human immunodeficiency virus 1 (HIV-1) is a human retrovirus that efficiently, albeit gradually, overruns the immune system. An already infected T lymphocyte can latch onto another T lymphocyte whereby creating a virological synapse (VS); this junction drives viral assembly and transfer to the target cell in batches in an efficient, protective manor. My Ph.D. doctoral thesis focused on studying this transmission mechanism using advanced optical imaging modalities and the fully infectious fluorescent clone HIV Gag-iGFP. T lymphocytes are non-adherent cells (˜10 um thick) and the viral transmission process is fairly dynamic, hence we employed a custom spinning disk confocal microscope that revealed many interesting characteristics of this cooperative event. This methodology has low throughput as cell contact and transfer is at random. Optical tweezers was then added to the microscope to directly initiate cell contact at will. To assess when viral maturation occurs post-transfer, an optical assay based off of Forster resonance energy transfer was developed to monitor maturation. Structured illumination microscopy was further used to image the process at higher resolution and it showed that viral particles are not entering existing degradative compartments. Non-HIV-1 applications of the optical technologies are also reviewed.
Pitch variable liquid lens array using electrowetting
NASA Astrophysics Data System (ADS)
Kim, YooKwang; Lee, Jin Su; Kim, Junoh; Won, Yong Hyub
2017-02-01
These days micro lens array is used in various fields such as fiber coupling, laser collimation, imaging and sensor system and beam homogenizer, etc. One of important thing in using micro lens array is, choice of its pitch. Especially imaging systems like integral imaging or light-field camera, pitch of micro lens array defines the system property and thus it could limit the variability of the system. There are already researches about lens array using liquid, and droplet control by electrowetting. This paper reports the result of combining them, the liquid lens array that could vary its pitch by electrowetting. Since lens array is a repeated system, realization of a small part of lens array is enough to show its property. The lens array is composed of nine (3 by 3) liquid droplets on flat surface. On substrate, 11 line electrodes are patterned along vertical and horizontal direction respectively. The width of line electrodes is 300um and interval is 200um. Each droplet is positioned to contain three electrode lines for both of vertical and horizontal direction. So there is one remaining electrode line in each of outermost side for both direction. In original state the voltage is applied to inner electrodes. When voltage of outermost electrodes are turned on, eight outermost droplets move to outer side, thereby increasing pitch of lens array. The original pitch was 1.5mm and it increased to 2.5mm after electrodes of voltage applied is changed.
VizieR Online Data Catalog: FIR spectra of AGNs from Herschel (Fernandez-Ontiveros+, 2016)
NASA Astrophysics Data System (ADS)
Fernandez-Ontiveros, J. A.; Spinoglio, L.; Pereira-Santaella, M.; Malkan, M. A.; Andreani, P.; Dasyra, K. M.
2016-11-01
The combination of Herschel/PACS during its 3.5yr of operational life and Spitzer/IRS allows us to cover the fine-structure emission lines from the mid- to the far-IR (10-200um in the rest-frame) for all the galaxies in the sample. This database was completed with the Herschel/SPIRE published values of the [NII]205um, and [CI]371,609um line fluxes (mainly from Kamenetzky+ 2016ApJ...829...93K). Table 8 collects published mid-IR (10-35um) fine-structure line fluxes measured with Spitzer/IRS for our samples of AGN and starburst galaxies. These values were complemented with unpublished IRS observations from the Spitzer archive. (10 data files).
NASA Astrophysics Data System (ADS)
Gao, Lingyu; Li, Xinghua; Guo, Qianrui; Quan, Jing; Hu, Zhengyue; Su, Zhikun; Zhang, Dong; Liu, Peilu; Li, Haopeng
2018-01-01
The internal structure of off-axis three-mirror system is commonly complex. The mirror installation error in assembly always affects the imaging line-of-sight and further degrades the image quality. Due to the complexity of the optical path in off-axis three-mirror optical system, the straightforward theoretical analysis on the variations of imaging line-of-sight is extremely difficult. In order to simplify the theoretical analysis, an equivalent single-mirror system is proposed and presented in this paper. In addition, the mathematical model of single-mirror system is established and the accurate expressions of imaging coordinate are derived. Utilizing the simulation software ZEMAX, off-axis three-mirror model and single-mirror model are both established. By adjusting the position of mirror and simulating the line-of-sight rotation of optical system, the variations of imaging coordinates are clearly observed. The final simulation results include: in off-axis three-mirror system, the varying sensitivity of the imaging coordinate to the rotation of line-of-sight is approximately 30 um/″; in single-mirror system, the varying sensitivity of the imaging coordinate to the rotation of line-of-sight is 31.5 um/″. Compared to the simulation results of the off-axis three-mirror model, the 5% relative error of single-mirror model analysis highly satisfies the requirement of equivalent analysis and also verifies its validity. This paper presents a new method to analyze the installation error of the mirror in the off-axis three-mirror system influencing on the imaging line-of-sight. Moreover, the off-axis three-mirror model is totally equivalent to the single-mirror model in theoretical analysis.
VizieR Online Data Catalog: OJ 287 far-infrared photometry (Kidger+, 2018)
NASA Astrophysics Data System (ADS)
Kidger, M.; Zola, S.; Valtonen, M.; Laehteenmaeki, A.; Jaervelae, E.; Tornikoski, M.; Tammi, J.; Liakos, A.; Poyner, G.
2017-11-01
A search was made using the Herschel Science Archive (HSA) for calibration observations of OJ 287 made in standard photometric observing modes. A total of five photometric observations were found, all taken with the SPIRE photometer (Griffin 2010), each giving simultaneous photometry at 250, 350, and 500um. The observations were made on four Operational Days (ODs) between 2010/04/20 and 2010/05/23. We have three sources of visible monitoring data for this period. Our first source is the data in R only from the database of long-term monitoring maintained at the Astronomical Observatory of the Jagiellonian University (Cracow, Poland). This consists of 27 observations obtained from 19 nights of photometry in R, taken between April 1 and May 28, 2010. Additionally, very high-quality data are publicly available from the SMARTS telescope (Bonning et al. 2012ApJ...756...13B) in B, V, and R. 26 sets of BVR photometry are available between April 1 and May 31, 2010. The SMARTS monitoring programme also obtains high-quality data in the J and K bands in the near-infrared. Three nights have visible, but no infrared photometry, hence J and K data are available on 23 nights in April and May 2010. The 37GHz observations were made with the 13.7m diameter Metsahovi radio telescope, which is a radome-enclosed paraboloid antenna situated in Finland. (1 data file).
Preamplifiers for non-contact capacitive biopotential measurements.
Peng, GuoChen; Ignjatovic, Zeljko; Bocko, Mark F
2013-01-01
Non-contact biopotential sensing is an attractive measurement strategy for a number of health monitoring applications, primarily the ECG and the EEG. In all such applications a key technical challenge is the design of a low-noise trans-impedance preamplifier for the typically low-capacitance, high source impedance sensing electrodes. In this paper, we compare voltage and charge amplifier designs in terms of their common mode rejection ratio, noise performance, and frequency response. Both amplifier types employ the same operational-transconductance amplifier (OTA), which was fabricated in a 0.35 um CMOS process. The results show that a charge amplifier configuration has advantages for small electrode-to-subject coupling capacitance values (less than 10 pF--typical of noncontact electrodes) and that the voltage amplifier configuration has advantages for electrode capacitances above 10 pF.
Code of Federal Regulations, 2010 CFR
2010-07-01
... maintain an SO2 continuous emission monitoring system and flow monitoring system in the duct to the common... emission monitoring system and flow monitoring system in the common stack and combine emissions for the... continuous emission monitoring system and flow monitoring system in the duct to the common stack from each...
The structure and large-scale organization of extreme cold waves over the conterminous United States
NASA Astrophysics Data System (ADS)
Xie, Zuowei; Black, Robert X.; Deng, Yi
2017-12-01
Extreme cold waves (ECWs) occurring over the conterminous United States (US) are studied through a systematic identification and documentation of their local synoptic structures, associated large-scale meteorological patterns (LMPs), and forcing mechanisms external to the US. Focusing on the boreal cool season (November-March) for 1950‒2005, a hierarchical cluster analysis identifies three ECW patterns, respectively characterized by cold surface air temperature anomalies over the upper midwest (UM), northwestern (NW), and southeastern (SE) US. Locally, ECWs are synoptically organized by anomalous high pressure and northerly flow. At larger scales, the UM LMP features a zonal dipole in the mid-tropospheric height field over North America, while the NW and SE LMPs each include a zonal wave train extending from the North Pacific across North America into the North Atlantic. The Community Climate System Model version 4 (CCSM4) in general simulates the three ECW patterns quite well and successfully reproduces the observed enhancements in the frequency of their associated LMPs. La Niña and the cool phase of the Pacific Decadal Oscillation (PDO) favor the occurrence of NW ECWs, while the warm PDO phase, low Arctic sea ice extent and high Eurasian snow cover extent (SCE) are associated with elevated SE-ECW frequency. Additionally, high Eurasian SCE is linked to increases in the occurrence likelihood of UM ECWs.
Chauhan, Aishwarya; Siddiqi, Nikhat Jamal
2014-01-01
A potential fungal strain of Trichoderma sp. (WF-3) was isolated and selected for the production of α-galactosidase. Optimum conditions for mycelial growth and enzyme induction were determined. Basal media selected for the growth of fungal isolate containing different carbon sources like guar gum (GG), soya bean meal (SM), and wheat straw (WS) and combinations of these carbon substrates with basic sugars like galactose and sucrose were used to monitor their effects on α-galactosidase production. The results of this study indicated that galactose and sucrose enhanced the enzyme activity in guar gum (GG) and wheat straw (WS). Maximum α-galactosidase production (213.63 UmL−1) was obtained when the basic medium containing GG is supplemented with galactose (5 mg/mL). However, the presence of galactose and sucrose alone in the growth media shows no effect. Soya meal alone was able to support T. evansii to produce maximum enzyme activity (170.36 UmL−1). The incubation time, temperature, and pH for the maximum enzyme synthesis were found to be 120 h (5 days), 28°C, and 4.5–5.5, respectively. All the carbon sources tested exhibited maximum enzyme production at 10 mg/mL concentration. Among the metal ions tested, Hg was found to be the strongest inhibitor of the enzyme. Among the chelators, EDTA acted as stronger inhibitor than succinic acid. PMID:25126562
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chan, Chai Ling; Yew, Su Mei; Ngeow, Yun Fong
Background: Daldinia eschscholtzii is a wood-inhabiting fungus that causes wood decay under certain conditions. It has a broad host range and produces a large repertoire of potentially bioactive compounds. However, there is no extensive genome analysis on this fungal species. Results: Two fungal isolates (UM 1400 and UM 1020) from human specimens were identified as Daldinia eschscholtzii by morphological features and ITS-based phylogenetic analysis. Both genomes were similar in size with 10,822 predicted genes in UM 1400 (35.8 Mb) and 11,120 predicted genes in UM 1020 (35.5 Mb). A total of 751 gene families were shared among both UM isolates,more » including gene families associated with fungus-host interactions. In the CAZyme comparative analysis, both genomes were found to contain arrays of CAZyme related to plant cell wall degradation. Genes encoding secreted peptidases were found in the genomes, which encode for the peptidases involved in the degradation of structural proteins in plant cell wall. In addition, arrays of secondary metabolite backbone genes were identified in both genomes, indicating of their potential to produce bioactive secondary metabolites. Both genomes also contained an abundance of gene encoding signaling components, with three proposed MAPK cascades involved in cell wall integrity, osmoregulation, and mating/filamentation. Besides genomic evidence for degrading capability, both isolates also harbored an array of genes encoding stress response proteins that are potentially significant for adaptation to living in the hostile environments. In conclusion: Our genomic studies provide further information for the biological understanding of the D. eschscholtzii and suggest that these wood-decaying fungi are also equipped for adaptation to adverse environments in the human host.« less
Activation pathways of synovial T lymphocytes. Expression and function of the UM4D4/CDw60 antigen.
Fox, D A; Millard, J A; Kan, L; Zeldes, W S; Davis, W; Higgs, J; Emmrich, F; Kinne, R W
1990-01-01
Accumulating evidence implicates a central role for synovial T cells in the pathogenesis of rheumatoid arthritis, but the activation pathways that drive proliferation and effector function of these cells are not known. We have recently generated a novel monoclonal antibody against a rheumatoid synovial T cell line that recognizes an antigen termed UM4D4 (CDw60). This antigen is expressed on a minority of peripheral blood T cells, and represents the surface component of a distinct pathway of human T cell activation. The current studies were performed to examine the expression and function of UM4D4 on T cells obtained from synovial fluid and synovial membranes of patients with rheumatoid arthritis and other forms of inflammatory joint disease. The UM4D4 antigen is expressed at high surface density on about three-fourths of synovial fluid T cells and on a small subset of synovial fluid natural killer cells; in synovial tissue it is present on more than 90% of T cells in lymphoid aggregates, and on approximately 50% of T cells in stromal infiltrates In addition, UM4D4 is expressed in synovial tissue on a previously undescribed population of HLA-DR/DP-negative non-T cells with a dendritic morphology. Anti-UM4D4 was co-mitogenic for both RA and non-RA synovial fluid mononuclear cells, and induced IL-2 receptor expression. The UM4D4/CDw60 antigen may represent a functional activation pathway for synovial compartment T cells, which could play an important role in the pathogenesis of inflammatory arthritis. Images PMID:2212003
Teunissen, Erik; Sherally, Jamilah; van den Muijsenbergh, Maria; Dowrick, Chris; van Weel-Baumgarten, Evelyn; van Weel, Chris
2014-01-01
Objective To explore health-seeking behaviour and experiences of undocumented migrants (UMs) in general practice in relation to mental health problems. Design Qualitative study using semistructured interviews and thematic analysis. Participants 15 UMs in the Netherlands, varying in age, gender, country of origin and education; inclusion until theoretical saturation was reached. Setting 4 cities in the Netherlands. Results UMs consider mental health problems to be directly related to their precarious living conditions. For support, they refer to friends and religion first, the general practitioner (GP) is their last resort. Barriers for seeking help include taboo on mental health problems, lack of knowledge of and trust in GPs competencies regarding mental health and general barriers in accessing healthcare as an UM (lack of knowledge of the right to access healthcare, fear of prosecution, financial constraints and practical difficulties). Once access has been gained, satisfaction with care is high. This is primarily due to the attitude of the GPs and the effectiveness of the treatment. Reasons for dissatisfaction with GP care are an experienced lack of time, lack of personal attention and absence of physical examination. Expectations of the GP vary, medication for mental health problems is not necessarily seen as a good practice. Conclusions UMs often see their precarious living conditions as an important determinant of their mental health; they do not easily seek help for mental health problems and various barriers hamper access to healthcare for them. Rather than for medication, UMs are looking for encouragement and support from their GP. We recommend that barriers experienced in seeking professional care are tackled at an institutional level as well as at the level of GP. PMID:25416057
Kobulnik, Jeremy; Kuliszewski, Michael A; Stewart, Duncan J; Lindner, Jonathan R; Leong-Poi, Howard
2009-10-27
This study was designed to compare the efficacy of angiogenic gene delivery by ultrasound-mediated (UM) destruction of intravenous carrier microbubbles to direct intramuscular (IM) injections. Current trials of gene therapy for angiogenesis remain limited by suboptimal, invasive delivery techniques. Hind-limb ischemia was produced by iliac artery ligation in 99 rats. In 32 rats, UM delivery of green fluorescent protein (GFP)/vascular endothelial growth factor-165 (VEGF(165)) plasmid deoxyribonucleic acid was performed. Thirty-five animals received IM injections of VEGF(165)/GFP plasmid. Remaining rats received no treatment. Before delivery (day 14 after ligation) and at days 17, 21, and 28 and week 8 after ligation, microvascular blood volume and microvascular blood flow to the proximal hind limbs were assessed by contrast-enhanced ultrasound (n = 8 per group). Total transfection was assessed by reverse transcriptase-polymerase chain reaction, and localization of transfection was determined by immunohistochemistry. By day 28, both IM and UM delivery of VEGF(165) produced significant increases in microvascular blood volume and microvascular blood flow. Whereas increases in microvascular blood volume were similar between treatment groups, microvascular blood flow was greater (p < 0.005) in UM-treated animals as compared with IM-treated animals, persisting to week 8. The VEGF(165)/GFP messenger ribonucleic acid expression was greater (p < 0.05) for IM-treated animals. A strong GFP signal was detected for both groups and was localized to focal perivascular regions and myocytes around injection sites for IM and to the vascular endothelium of arterioles/capillaries in a wider distribution for UM delivery. Despite lower transfection levels, UM delivery of VEGF(165) is as effective as IM injections. The UM delivery results in directed vascular transfection over a wider distribution, which may account for the more efficient angiogenesis.
Teunissen, Erik; Van Bavel, Eric; Van Den Driessen Mareeuw, Francine; Macfarlane, Anne; Van Weel-Baumgarten, Evelyn; Van Den Muijsenbergh, Maria; Van Weel, Chris
2015-06-01
To explore the views and experiences of general practitioners (GPs) in relation to recognition, recording, and treatment of mental health problems of undocumented migrants (UMs), and to gain insight in the reasons for under-registration of mental health problems in the electronic medical records. Qualitative study design with semi-structured interviews using a topic guide. Sixteen GPs in the Netherlands with clinical expertise in the care of UMs. GPs recognized many mental health problems in UMs. Barriers that prevented them from recording these problems and from delivering appropriate care were their low consultation rates, physical presentation of mental health problems, high number of other problems, the UM's lack of trust towards health care professionals, and cultural differences in health beliefs and language barriers. Referrals to mental health care organizations were often seen as problematic by GPs. To overcome these barriers, GPs provided personalized care as far as possible, referred to other primary care professionals such as social workers or mental health care nurses in their practice, and were a little less restrictive in prescribing psychotropics than guidelines recommended. GPs experienced a variety of barriers in engaging with UMs when identifying or suspecting mental health problems. This explains why there is a gap between the high recognition of mental health problems and the low recording of these problems in general practice files. It is recommended that GPs address mental health problems more actively, strive for continuity of care in order to gain trust of the UMs, and look for opportunities to provide mental care that is accessible and acceptable for UMs.
Di Paola, Rosanna; Cordaro, Marika; Crupi, Rosalia; Siracusa, Rosalba; Campolo, Michela; Bruschetta, Giuseppe; Fusco, Roberta; Pugliatti, Pietro; Esposito, Emanuela; Cuzzocrea, Salvatore
2016-08-01
Myocardial infarction is the leading cause of death, occurs after prolonged ischemia of the coronary arteries. Restore blood flow is the first intervention help against heart attack. However, reperfusion of the arteries leads to ischemia/reperfusion injury (I/R). The fatty acid amide palmitoylethanolamide (PEA) is an endogenous compound widely present in living organisms, with analgesic and anti-inflammatory properties. The present study evaluated the effect of ultramicronized palmitoylethanolamide (PEA-um) treatment on the inflammatory process associated with myocardial I/R. Myocardial ischemia reperfusion injury was induced by occlusion of the left anterior descending coronary artery for 30 min followed by 2 h of reperfusion. PEA-um, was administered (10 mg/kg) 15 min after ischemia and 1 h after reperfusion. In this study, we demonstrated that PEA-um treatment reduces myocardial tissue injury, neutrophil infiltration, adhesion molecules (ICAM-1, P-selectin) expression, proinflammatory cytokines (TNF-α, IL-1β) production, nitrotyrosine and PAR formation, nuclear factor kB expression, and apoptosis (Fas-L, Bcl-2) activation. In addition to study whether the protective effect of PEA-um on myocardial ischemia reperfusion injury is also related to the activation of PPAR-α, in a separate set of experiments it has been performed myocardial I/R in PPARα mice. Genetic ablation of peroxisome proliferator activated receptor (PPAR)-α in PPAR-αKO mice exacerbated Myocardial ischemia reperfusion injury when compared with PPAR-αWT mice. PEA-um induced cardioprotection in PPAR-α wild-type mice, but the same effect cannot be observed in PPAR-αKO mice. Our results have clearly shown a modulation of the inflammatory process, associated with myocardial ischemia reperfusion injury, following administration of PEA-um.
Contralateral prophylactic mastectomy rate stable at major Canadian breast cancer center.
Roberts, Amanda; Sandhu, Lakhbir; Cil, Tulin D; Hofer, Stefan O P; Zhong, Toni
2016-06-10
To examine trends of contralateral prophylactic mastectomy (CPM) rates at a Canadian academic breast cancer center. A single-institution retrospective cohort study was completed. Women of any age who underwent at least a unilateral mastectomy (UM) for primary unilateral breast carcinoma between January 1, 2004 and December 31, 2010 were included. Patients who underwent CPM on the same day as UM were isolated to create two distinct cohorts. Patient and procedure characteristics were compared across groups using R software (version 3.1.0). The percentage of CPMs per year was determined. The Cochrane-Armitage test was used to assess the trend of CPMs over time. A P value of < 0.05 was considered significant. A total of 811 women met the inclusions/exclusion criteria; 759 (93.6%) underwent UM alone and 52 (6.4%) underwent UM with immediate CPM. The absolute number of procedures (UM and UM + CPM) increased over time, from 83 in 2004 to 147 in 2010 reflecting an increase in mastectomy volume. Annual CPM rates did not increase over time (P = 0.7) and varied between 2.6% to 10.7%. Family history of breast cancer [OR 3.6 (1.8-7.3)] and immediate reconstruction [10.0 (5.2-19.3)] were both significantly associated with CPM. Women who underwent CPM were younger (median age CPM 49 years vs UM 52 years, P < 0.0001) but age less than 50 years was not statistically associated with increased rates of CPM. CPM rates from 2004 to 2010 at a high-volume Canadian breast cancer center did not increase over time, in contrast to trends observed in the United States.
First Asteroid Spectrometric Observations with BTA: 3045 Alois
NASA Astrophysics Data System (ADS)
Busarev, V. V.; Burenkov, A. N.; Pramskij, A. G.
2001-11-01
BTA, Russian 6-m telescope, was mainly used for faint stars and extragalactic objects observations. We have firstly performed with the telescope spectrometric observations of a main belt asteroid, 3045 Alois, and are planning to use it for Centaurs and Kuiper Belt objects spectrometry. We have obtained some results of the observations. Spectra of Alois were recorded on two nights of March 2001 (29/30 and 30/31) with a long slit spectrograph (UAGS + CCD) in the .38-.80 um spectral range. HD105633 (G5) [1] considered as a solar analog was also observed, and the data were used for calculation the asteroid reflectance spectra. It was found that reflectance spectra of Alois obtained on different nights have various continuum slopes and absorption features. The reflectance spectrum on 29/30 March had a flat continuum in the range .44-.65 um and absorption bands at .5 um (ab. 7 % with respect to the continuum) similar to that found on the E-type asteroid 2035 Stearns [2], and at .80 um (ab. 25 %). Another one on 30/31 March had a red continuum in the range .40-.67 um and absorption bands at .43 um (ab. 6 %) resembling absorption features found on some C-, M- and S-type asteroids [3, 4], and at .80 um (ab. 17 %). From the data and taking into account the mean heliocentric distance of 3045 Alois (3.13 AU) we suppose that the asteroid having irregular spectral characteristics may be of M- or E-type and possibly hydrated. Unfortunately, its albedo and rotational period remain still unknown. [1] Mermilliod J.-C. (1994) Bull. Inf. CDS 45, 3. [2] Fornasier S. and Lazzarine M. (2001) Icarus 152, 127-133. [3] Vilas F. et al. (1993) Icarus 102, 225-231. [4] Busarev V. V. (2001) LPSC XXXII, abs. 1927.
Chan, Chai Ling; Yew, Su Mei; Ngeow, Yun Fong; ...
2015-11-18
Background: Daldinia eschscholtzii is a wood-inhabiting fungus that causes wood decay under certain conditions. It has a broad host range and produces a large repertoire of potentially bioactive compounds. However, there is no extensive genome analysis on this fungal species. Results: Two fungal isolates (UM 1400 and UM 1020) from human specimens were identified as Daldinia eschscholtzii by morphological features and ITS-based phylogenetic analysis. Both genomes were similar in size with 10,822 predicted genes in UM 1400 (35.8 Mb) and 11,120 predicted genes in UM 1020 (35.5 Mb). A total of 751 gene families were shared among both UM isolates,more » including gene families associated with fungus-host interactions. In the CAZyme comparative analysis, both genomes were found to contain arrays of CAZyme related to plant cell wall degradation. Genes encoding secreted peptidases were found in the genomes, which encode for the peptidases involved in the degradation of structural proteins in plant cell wall. In addition, arrays of secondary metabolite backbone genes were identified in both genomes, indicating of their potential to produce bioactive secondary metabolites. Both genomes also contained an abundance of gene encoding signaling components, with three proposed MAPK cascades involved in cell wall integrity, osmoregulation, and mating/filamentation. Besides genomic evidence for degrading capability, both isolates also harbored an array of genes encoding stress response proteins that are potentially significant for adaptation to living in the hostile environments. In conclusion: Our genomic studies provide further information for the biological understanding of the D. eschscholtzii and suggest that these wood-decaying fungi are also equipped for adaptation to adverse environments in the human host.« less
Aircraft Natural/Artificial Icing
2009-02-12
LWC are 0.1 to 0.8 g/m3 for stratiform clouds and 0.2 to 2.5 g/m3 for cumuliform clouds. The drop size distribution in the cloud is usually...cloud hydrometeor size distributions from 0.5 to 50 um, particle shape (discrimination between water and ice), particle optical properties (refractive...index), precipitation size distributions from 25 um to 1550 um, liquid water content from 0.01 to 3 gm-3 and aircraft velocity and atmospheric
Novel Preclinical Testing Strategies for Treatment of Metastatic Pheochromocytoma
2013-09-01
proliferation using this protocol as reported or with any modifications tested Medium Y27632 (uM) Hydrocortisone (ug/mL) Insulin (ug/mL) rhEGF...0 + + 0 + + 0 + 0 Medium Y27632 (uM) Hydrocortisone (ug/mL) Insulin (ug/mL) rhEGF (ng/mL) Adenine (ug/mL) Result...reported (1) except for cholera toxin, which was toxic to this tumor under these conditions 17 Medium Y27632 (uM) Hydrocortisone (ug/mL
Novel Manufacturing Technologies for GHZ/THz Integrated Circuits on Synthetic Diamond Substrates
2010-11-15
silicon form palladium silicide Pd2Si at a temperature of 400 ºС, thus ensuring high reliability of the contacts. All the above metallization layers were...indicate possibility of realization of ICs on diamond substrates. In the course of our studies it was found that the Ti-Pd-Au metallization system...thickness of 2-3 um) can be applied when forming the topology of IC elements on synthetic diamond layers, while the Cr–Cu–Ni–Au metallization system with
2000-06-01
Anwendung und Pflege des neuen Systems dienen soil, wenn die entscheidenden Vorgaben bereits durch die Deckelung gegeben sind. Oder denkt man an den...Software und die da- mit verbundenen Lizenzgebuhren, sondern auch in der Folge um die Schulung der Mitarbeiter sowie die Pflege und Weiterentwicklung...sung an die medizinische Entwicklung" sowie von "Verfahren zur laufen- den Pflege des VergOtungssystems" gesprochen. Es mossen jedoch klare
1999-06-18
and 1.54 microns and to compute the spectral extinction coefficient. 3. Near IR (1.54 um) Laser rangefinders measure the time-of-flight of a short...quantitative understanding n n Research ( long term) n Encourage research in adaptive systems : evolutionary programming, genetic algorithms, neural nets... measures , such as false alarm rate , are not measurable in field applications. Other measures such as Incremental Fault Resolution, Operational Isolation
VizieR Online Data Catalog: Spitzer obs. of warm dust in 83 debris disks (Ballering+, 2017)
NASA Astrophysics Data System (ADS)
Ballering, N. P.; Rieke, G. H.; Su, K. Y. L.; Gaspar, A.
2018-04-01
For our sample, we used the systems with a warm component found by Ballering+ (2013, J/ApJ/775/55), where "warm" was defined as warmer than 130K. All of these systems have data available from the Multiband Imaging Photometer for Spitzer (MIPS) at 24 and 70um and from the Spitzer Infrared Spectrograph (IRS). The selected 83 targets used for our analysis are listed in Table 1. (5 data files).
1982-11-01
band, due to higher molecular absorption by water vapor in the 8-12 um band. On the other hand, aerosol extinction may affect the shorter wavelenghts ...precipitation, and aerosol growth . While relative humidity is a LOWTRAN 5 model input, single parameter sensitivity analysis indicates that this fact alone does...M.J., and Vaklyes, D.W., Comparison of Canadian and German Weather, Systems Planning Corporation SPP 566, March 1980. 13. Atwater, M.A., and Ball
BRD4-targeted therapy induces Myc-independent cytotoxicity in Gnaq/11-mutatant uveal melanoma cells.
Ambrosini, Grazia; Sawle, Ashley D; Musi, Elgilda; Schwartz, Gary K
2015-10-20
Uveal melanoma (UM) is an aggressive intraocular malignancy with limited therapeutic options. Both primary and metastatic UM are characterized by oncogenic mutations in the G-protein alpha subunit q and 11. Furthermore, nearly 40% of UM has amplification of the chromosomal arm 8q and monosomy of chromosome 3, with consequent anomalies of MYC copy number. Chromatin regulators have become attractive targets for cancer therapy. In particular, the bromodomain and extra-terminal (BET) inhibitor JQ1 has shown selective inhibition of c-Myc expression with antiproliferative activity in hematopoietic and solid tumors. Here we provide evidence that JQ1 had cytotoxic activity in UM cell lines carrying Gnaq/11 mutations, while in cells without the mutations had little effects. Using microarray analysis, we identified a large subset of genes modulated by JQ1 involved in the regulation of cell cycle, apoptosis and DNA repair. Further analysis of selected genes determined that the concomitant silencing of Bcl-xL and Rad51 represented the minimal requirement to mimic the apoptotic effects of JQ1 in the mutant cells, independently of c-Myc. In addition, administration of JQ1 to mouse xenograft models of Gnaq-mutant UM resulted in significant inhibition of tumor growth.Collectively, our results define BRD4 targeting as a novel therapeutic intervention against UM with Gnaq/Gna11 mutations.
Unsaponifiable matter from oil of green coffee beans: cosmetic properties and safety evaluation.
Wagemaker, Tais A L; Campos, Patrícia M B G Maia; Fernandes, Ana Sofia; Rijo, Patrícia; Nicolai, Marisa; Roberto, Amílcar; Rosado, Catarina; Reis, Catarina; Rodrigues, Luis M; Carvalho, Cássia Regina Limonta; Maia, Nilson Borlina; Guerreiro Filho, Oliveiro
2016-10-01
Unsaponifiable matter (UM), a fraction of green coffee oil (GCO) contains functional compounds responsible for desirable cosmetic properties such as UV-B absorption. To evaluate oil content and sun protection factor (SPF) variability of the two most important species of coffee and, the toxic and cytotoxic effects, as well as cosmetic properties, including antioxidant and antimicrobial activities of UM obtained from green Coffea arabica seed oil. The safety and potential cosmetic properties of UM extracted from green coffee oil (GCO) were evaluated by the brine shrimp viability and the MTT cytotoxicity assays. The SPF and antioxidant activity were evaluated using in vitro methods. Relevant cytotoxicity was found against keratinocytes for concentrations ≥25 µg/mL and in the brine shrimp assay (LC50 24 µg/mL). Antimicrobial and antioxidant activities (IC50 1448 µg/mL) were low in UM but SPF was 10 times higher than in GCO. UM is a novel potential UV-B absorbent but its use as a cosmetic ingredient should be better considered due to the considerable cytotoxicity shown in the experimental conditions described.
Medusa consumption and prey selection of silver pomfret Pampus argenteus juveniles
NASA Astrophysics Data System (ADS)
Liu, Chunsheng; Zhuang, Zhimeng; Chen, Siqing; Shi, Zhaohong; Yan, Jingping; Liu, Changlin
2014-01-01
The current study explored Aurelia aurita and Rhopilema esculent um consumption by silver pomfret juveniles, as well as their prey selection between the two jellyfish species. Silver pomfret juveniles weighing 1±0.1 g actively preyed on both the species. Their daily A. aurita consumption was 11.6 times their own body weights regardless of the size of A. aurita medusae. Their daily R. esculent um consumption was 13, 9.1, 5, and 4.1 times their own body weights when the R. esculentum medusae were 10, 20, 30, and 40 mm in bell diameter, respectively. The survival rates of the R. esculent um were higher than those of the A. aurita. When the R. esculent um medusae were more than 30 mm in bell diameter, their survival rate exceeded 92%. Silver pomfrets serve as a type of potential predators on A. aurita in coastal waters, and they have little influence on R. esculent um with a size exceeding 30 mm. Besides, A. aurita may be able to be used as fish prey in silver pomfret artificial breeding.
Design of a concise Féry-prism hyperspectral imaging system based on multi-configuration
NASA Astrophysics Data System (ADS)
Dong, Wei; Nie, Yun-feng; Zhou, Jin-song
2013-08-01
In order to meet the needs of space borne and airborne hyperspectral imaging system for light weight, simplification and high spatial resolution, a novel design of Féry-prism hyperspectral imaging system based on Zemax multi-configuration method is presented. The novel structure is well arranged by analyzing optical monochromatic aberrations theoretically, and the optical structure of this design is concise. The fundamental of this design is Offner relay configuration, whereas the secondary mirror is replaced by Féry-prism with curved surfaces and a reflective front face. By reflection, the light beam passes through the Féry-prism twice, which promotes spectral resolution and enhances image quality at the same time. The result shows that the system can achieve light weight and simplification, compared to other hyperspectral imaging systems. Composed of merely two spherical mirrors and one achromatized Féry-prism to perform both dispersion and imaging functions, this structure is concise and compact. The average spectral resolution is 6.2nm; The MTFs for 0.45~1.00um spectral range are greater than 0.75, RMSs are less than 2.4um; The maximal smile is less than 10% pixel, while the keystones is less than 2.8% pixel; image quality approximates the diffraction limit. The design result shows that hyperspectral imaging system with one modified Féry-prism substituting the secondary mirror of Offner relay configuration is feasible from the perspective of both theory and practice, and possesses the merits of simple structure, convenient optical alignment, and good image quality, high resolution in space and spectra, adjustable dispersive nonlinearity. The system satisfies the requirements of airborne or space borne hyperspectral imaging system.
VizieR Online Data Catalog: Multiwavelength study of HII region S311 (Yadav+, 2016)
NASA Astrophysics Data System (ADS)
Yadav, R. K.; Pandey, A. K.; Sharma, S.; Ojha, D. K.; Samal, M. R.; Mallick, K. K.; Jose, J.; Ogura, K.; Richichi, A.; Irawati, P.; Kobayashi, N.; Eswaraiah, C.
2017-11-01
We observed the HII region S311 (centred on RA(2000)=07:52:24, DE(2000)=-26:24:58.40) in NIR broad-bands J (1.25um), H (1.63um) and Ks (2.14um) on 2010 March 3 using the Infrared Side Port Imager (ISPI) camera mounted on the CTIO Blanco 4-m telescope. We consider only those sources having error <0.1mag in all three bands, resulting in a final catalogue of 2671 point sources. The Spitzer-IRAC observations for the S311 region (PID 20726) were made on 2006 May 3 using the 3.6, 4.5, 5.8 and 8.0um bands and were downloaded from the Spitzer heritage archive (SHA). (4 data files).
VizieR Online Data Catalog: UKIDSS-DR7 Large Area Survey (Lawrence+ 2011)
NASA Astrophysics Data System (ADS)
UKIDSS Consortium
2012-03-01
The UKIRT Infrared Deep Sky Survey (UKIDSS) is a large-scale near-IR survey which aim is to cover 7500 square degrees of the Northern sky. The survey is carried out using the Wide Field Camera (WFCAM), with a field of view of 0.21 square degrees, mounted on the 3.8m United Kingdom Infra-red Telescope (UKIRT) in Hawaii. The Large Area Survey (LAS) covers an area of 4000 square degrees in high Galactic latitudes (extragalactic) in the four bands Y(1.0um) J(1.2um) H(1.6um) and K(2.2um) to a depth of K = 18.4. Details of the survey can be found in the in the paper by Lawrence et al. (2007MNRAS.379.1599L) (1 data file).
Misalignment tolerant efficient inverse taper coupler for silicon waveguide
NASA Astrophysics Data System (ADS)
Wang, Peng; Michael, Aron; Kwok, Chee Yee; Chen, Ssu-Han
2015-12-01
This paper describes an efficient fiber to submicron silicon waveguide coupling based on an inversely tapered silicon waveguide embedded in a SiO2 waveguide that is suspended in air. The inverse taper waveguide consist of a 50um long and 240nm thick silicon that linearly taper in width from 500nm to 120nm, which is embedded in SiO2. The SiO2 waveguide is 6um wide and 10um long. The simulation results show that the coupling loss of this new approach is 2.7dB including the interface loss at the input and output. The tolerance to fiber misalignment at the input of the coupler is 2um in both horizontal and vertical directions for only 1.5dB additional loss.
Effect of aluminum treatment on proteomes of radicles of seeds derived from Al-treated tomato plants
USDA-ARS?s Scientific Manuscript database
Aluminum (Al) toxicity is a major constraint to plant growth and crop yield in acid soils. Tomato cultivars are especially susceptible to excessive A1 3+ accumulated in the root zone. In this study, tomato plants were grown in a hydroponic culture system supplemented with 50 uM AlK(SO4)2. Seeds harv...
Convective Electrokinetic Instability With Conductivity Gradients
NASA Astrophysics Data System (ADS)
Chen, Chuan-Hua; Lin, Hao; Lele, Sanjiva; Santiago, Juan
2003-11-01
Electrokinetic flow instability has been experimentally identified and quantified in a glass T-junction microchannel system with a cross section of 11 um x 155 um. In this system, buffers of different conductivities were electrokinetically driven into a common mixing channel by a DC electric field. A convective instability was observed with a threshold electric field of 0.45 kV/cm for a 10:1 conductivity ratio. A physical model has been developed which consists of a modified Ohmic model formulation for electrolyte solutions and the Navier-Stokes equations with an electric body force term. The model and experiments show that bulk charge accumulation in regions of conductivity gradients is the key mechanism of such instabilities. A linear stability analysis was performed in a convective framework, and Briggs-Bers criteria were applied to determine the nature of instability. The analysis shows the instability is governed by two key parameters: the ratio of molecular diffusion to electroviscous time scale which governs the onset of instability, and the ratio of electroviscous to electroosmotic velocity which governs whether the instability is convective or absolute. The model predicted critical electric field, growth rate, wavelength, and phase speed which were comparable to experimental data.
Schnelle, Christoph; Minford, Eunice J; McHardy, Vanessa; Keep, Jane
2017-11-23
Longitudinal studies of women's health often seek to identify predictors of good health. Research has shown that following simple guidelines can halve women's mortality. The ongoing Australian Longitudinal Study of Women's Health (ALSWH) shows that Australian women are getting better at reducing their smoking and alcohol use, and are generally diligent about attending recommended health screenings, but are becoming less successful at dealing with obesity. There are communities of women who live unusually healthy lives (Rosetans, Seventh-Day Adventists, traditional Japanese women), but their lifestyles are unlikely to be adopted widely. Universal Medicine (UM) is a complementary-to-medicine approach that emphasizes personal empowerment and the importance of menstrual health symptoms. This survey investigates whether the approximately 500 women associated with UM exhibit health status significantly above the norm. As part of this investigation, questions for a newly developed menstrual attitudes questionnaire will also be evaluated. A quantitative cross-sectional survey of women in a UM cohort was designed with the help of three focus groups of women at three life stages: in menses, peri-menopausal, and menopausal. The menstrual attitudes portion of the survey incorporates the insights of these women regarding female health issues. The survey also includes 41 questions taken from the ALSWH. Focus groups generated additional questions about symptoms experienced and attitudes toward female health issues. ALSWH questions, including a range of health scales like the Short Form 36 (SF-36), Center for Epidemiologic Studies Depression Scale, Perceived Control Scale, Kessler Psychological Distress Scale, and the Multi-Item Summed Score for Perceived Stress, along with questions about experienced major health events, were investigated and incorporated if considered suitable. The validity of the menstrual attitudes questionnaire will be evaluated with Cohen's kappa. ALSWH respondents and UM participants will be compared, using unweighted regression or regression weighted or normalized by age, education, and interest in alternative treatments (to increase comparability), as appropriate. Analyses will determine whether UM-related variables (being a UM participant, length of UM participation, number of UM events attended) are associated with: differences in the number of major health events and health symptoms experienced; SF-36 physical and mental health scores; body mass index; and consumption of alcohol, tobacco, sugar, salt, caffeine, and dairy. If women in the UM cohort are truly in substantially better health than the norm, further investigations may be worthwhile to see whether UM plays a causal role, and whether the women's practices are generalizable. ©Christoph Schnelle, Eunice J Minford, Vanessa McHardy, Jane Keep. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 23.11.2017.
Hypermethylation of AP-2Alpha as a Prognostic Marker for DCIS
2008-05-01
Unfortunately, among the methylation status of the AP2, CYCLIN D, ECAD , GSTP, and SSOCS genes, either as individual genes, or in combinations, no...0.61 to 4.10) 1.00 (referent) 0.35 ECAD M UM 0 100 3 97 GSTP M UM 40 60 24 76 2.02 (0.72 to 5.64) 1.00...Missing data: 1.4% for AP2, CYCLIN D, ECAD , GSTP; 4.2% for SSOCS; 2.8% for nuclear grade. §M=methylated; UM=unmethylated; +Two-sided
Attache Extraordinaire: Vernon A. Walters and Brazil
2009-03-01
contudo, o primeiro encontro com um brasileiro. De acordo com uma entrevista que Walters concedeu, em 1966, ao Jornal O Globo, o primeiro brasileiro...21 de fevereiro de 1964, às 18 h, Lincoln Gordon enviou um telegrama ao Departamento de Estado. A mensagem dava conta de um encontro que o...disposição de Goulart em assumir riscos extremos, por meio do incentivo a violência esporádica no interior, encontros de grandes multidões e greves com o
EPMOSt: An Energy-Efficient Passive Monitoring System for Wireless Sensor Networks
Garcia, Fernando P.; Andrade, Rossana M. C.; Oliveira, Carina T.; de Souza, José Neuman
2014-01-01
Monitoring systems are important for debugging and analyzing Wireless Sensor Networks (WSN). In passive monitoring, a monitoring network needs to be deployed in addition to the network to be monitored, named the target network. The monitoring network captures and analyzes packets transmitted by the target network. An energy-efficient passive monitoring system is necessary when we need to monitor a WSN in a real scenario because the lifetime of the monitoring network is extended and, consequently, the target network benefits from the monitoring for a longer time. In this work, we have identified, analyzed and compared the main passive monitoring systems proposed for WSN. During our research, we did not identify any passive monitoring system for WSN that aims to reduce the energy consumption of the monitoring network. Therefore, we propose an Energy-efficient Passive MOnitoring SysTem for WSN named EPMOSt that provides monitoring information using a Simple Network Management Protocol (SNMP) agent. Thus, any management tool that supports the SNMP protocol can be integrated with this monitoring system. Experiments with real sensors were performed in several scenarios. The results obtained show the energy efficiency of the proposed monitoring system and the viability of using it to monitor WSN in real scenarios. PMID:24949639
Code of Federal Regulations, 2011 CFR
2011-07-01
... monitoring requirements for a continuous emissions monitoring system? 63.7747 Section 63.7747 Protection of... apply for alternative monitoring requirements for a continuous emissions monitoring system? (a) You may... prevention technique, a description of the continuous monitoring system or method including appropriate...
Code of Federal Regulations, 2010 CFR
2010-07-01
... monitoring requirements for a continuous emissions monitoring system? 63.7747 Section 63.7747 Protection of... apply for alternative monitoring requirements for a continuous emissions monitoring system? (a) You may... prevention technique, a description of the continuous monitoring system or method including appropriate...
Peng, Jun; Chen, Yi-Ting; Chen, Chien-Lun; Li, Liang
2014-07-01
Large-scale metabolomics study requires a quantitative method to generate metabolome data over an extended period with high technical reproducibility. We report a universal metabolome-standard (UMS) method, in conjunction with chemical isotope labeling liquid chromatography-mass spectrometry (LC-MS), to provide long-term analytical reproducibility and facilitate metabolome comparison among different data sets. In this method, UMS of a specific type of sample labeled by an isotope reagent is prepared a priori. The UMS is spiked into any individual samples labeled by another form of the isotope reagent in a metabolomics study. The resultant mixture is analyzed by LC-MS to provide relative quantification of the individual sample metabolome to UMS. UMS is independent of a study undertaking as well as the time of analysis and useful for profiling the same type of samples in multiple studies. In this work, the UMS method was developed and applied for a urine metabolomics study of bladder cancer. UMS of human urine was prepared by (13)C2-dansyl labeling of a pooled sample from 20 healthy individuals. This method was first used to profile the discovery samples to generate a list of putative biomarkers potentially useful for bladder cancer detection and then used to analyze the verification samples about one year later. Within the discovery sample set, three-month technical reproducibility was examined using a quality control sample and found a mean CV of 13.9% and median CV of 9.4% for all the quantified metabolites. Statistical analysis of the urine metabolome data showed a clear separation between the bladder cancer group and the control group from the discovery samples, which was confirmed by the verification samples. Receiver operating characteristic (ROC) test showed that the area under the curve (AUC) was 0.956 in the discovery data set and 0.935 in the verification data set. These results demonstrated the utility of the UMS method for long-term metabolomics and discovering potential metabolite biomarkers for diagnosis of bladder cancer.
Monitoring Distributed Real-Time Systems: A Survey and Future Directions
NASA Technical Reports Server (NTRS)
Goodloe, Alwyn E.; Pike, Lee
2010-01-01
Runtime monitors have been proposed as a means to increase the reliability of safety-critical systems. In particular, this report addresses runtime monitors for distributed hard real-time systems. This class of systems has had little attention from the monitoring community. The need for monitors is shown by discussing examples of avionic systems failure. We survey related work in the field of runtime monitoring. Several potential monitoring architectures for distributed real-time systems are presented along with a discussion of how they might be used to monitor properties of interest.
Warpage Measurement of Thin Wafers by Reflectometry
NASA Astrophysics Data System (ADS)
Ng, Chi Seng; Asundi, Anand Krishna
To cope with advances in the electronic and portable devices, electronic packaging industries have employed thinner and larger wafers to produce thinner packages/ electronic devices. As the thickness of the wafer decrease (below 250um), there is an increased tendency for it to warp. Large stresses are induced during manufacturing processes, particularly during backside metal deposition. The wafers bend due to these stresses. Warpage results from the residual stress will affect subsequent manufacturing processes. For example, warpage due to this residual stresses lead to crack dies during singulation process which will severely reorient the residual stress distributions, thus, weakening the mechanical and electrical properties of the singulated die. It is impossible to completely prevent the residual stress induced on thin wafers during the manufacturing processes. Monitoring of curvature/flatness is thus necessary to ensure reliability of device and its uses. A simple whole-field curvature measurement system using a novel computer aided phase shift reflection grating method has been developed and this project aims to take it to the next step for residual stress and full field surface shape measurement. The system was developed from our earlier works on Computer Aided Moiré Methods and Novel Techniques in Reflection Moiré, Experimental Mechanics (1994) in which novel structured light approach was shown for surface slope and curvature measurement. This method uses similar technology but coupled with a novel phase shift system to accurately measure slope and curvature. In this study, slope of the surface were obtain using the versatility of computer aided reflection grating method to manipulate and generate gratings in two orthogonal directions. The curvature and stress can be evaluated by performing a single order differentiation on slope data.
Mobile Particulate Emission Measurements of New York City Transit Buses and Other in use Vehicles
NASA Astrophysics Data System (ADS)
Jayne, J. T.; Canagaratna, M.; Herndon, S.; Shorter, J.; Zahniser, M.; Kolb, C.; Williams, L.; Worsnop, D.; Drewnick, F.; Demerjian, K. L.; Lanni, T.
2002-12-01
Emissions from both diesel and gasoline powered motor vehicles are a significant source of particulate (PM2.5) and trace gas pollution, especially in urban environments. Emission characterizations of motor vehicles can be performed using a dynamometer but these studies make fleet characterization impractical. Few studies have been performed which characterize emissions from in-use vehicles using a mobile sampling platform. This work describes application of new technology instrumentation for rapid (1-5 second) and real-time characterization of both gas and particulate emissions from in-use vehicles and is part of the PM2.5 Technology Assessment and Characterization Study in New York (PMTACS-NY). An aerosol mass spectrometer (AMS) and a tunable infrared laser differential absorption spectrometer (TILDAS) system were deployed on the Aerodyne Research mobile laboratory designed to "chase" target vehicles in and around the New York City area and measure their emissions under actual driving conditions. The AMS provides particle size and composition information for volatile and semi-volatile matter (0.03 - 1 um) while the TILDAS system was configured to measure NO, NO2, CO, CH4, SO2 and formaldehyde. In addition to a global positioning system, an ELPI and a condensation particle counter, the mobile laboratory was also equipped with a Licor CO2 monitor to allow emission indices to be computed for the targeted vehicles. Emission indices for both particulate and trace gases correlated with engine type are reported for a representative fraction of the NYC Metropolitan Transit Authority (MTA) bus fleet in an effort to characterize new emission control technologies currently implemented by the NYC MTA.
Current concepts in blood glucose monitoring
Khadilkar, Kranti Shreesh; Bandgar, Tushar; Shivane, Vyankatesh; Lila, Anurag; Shah, Nalini
2013-01-01
Blood glucose monitoring has evolved over the last century. The concept of adequate glycemic control and minimum glycemic variability requires an ideal, accurate and reliable glucose monitoring system. The search for an ideal blood glucose monitoring system still continues. This review explains the various blood glucose monitoring systems with special focus on the monitoring systems like self- monitored blood glucose (SMBG) and continuous glucose monitoring system (CGMS). It also focuses on the newer concepts of blood glucose monitoring and their incorporation in routine clinical management of diabetes mellitus. PMID:24910827
NASA Astrophysics Data System (ADS)
Memon, Sanober F.; Lewis, Elfed; Pembroke, J. Tony; Chowdhry, Bhawani S.
2017-04-01
A novel, low cost and highly sensitive optical fibre probe sensor for concentration measurement of ethanol solvent (C2H5OH) corresponding to bio-ethanol production rate by an algae is reported. The principle of operation of the sensor is based on inter-fibre light coupling through an evanescent field interaction to couple the light between two multimode fibres mounted parallel to each other at a minimum possible separation i.e. < 1mm. The sensor was fabricated using a low cost 1000um plastic optical fibre (POF) and was characterized for real time measurement in the broadband spectrum including visible and near infra-red. The wavelength dependency of this sensor design was also investigated by post processing analysis of real time data and hence the optimum wavelength range determined. The proposed sensor has shown significant response in the range of 0.005 - 0.1 %v/v (%volume/volume or volume concentration) which depicts the high sensitivity for monitoring very minute changes in concentration corresponding refractive index changes of the solution. Numerically, sensor has shown the sensitivity of 21945 intensity counts/%v/v or 109.7 counts per every 0.0050 %v/v.
Li, Ye; Röhrl, Stephan M; Bøe, B; Nordsletten, Lars
2014-09-01
Radiostereometric analysis (RSA) is the gold standard of measurement for in vivo 3D implants migration. The aim of this study was to evaluate the in vivo precision of 2 RSA marker-based systems compared with that of marker-free, elementary geometrical shape modeling RSA. Stem migration was measured in 50 patients recruited from an on-going Randomized Controlled Trial. We performed marker-based analysis with the Um RSA and RSAcore systems and compared these results with those of the elementary geometrical shape RSA. The precision for subsidence was 0.118 mm for Um RSA, 0.141 mm for RSAcore, and 0.136 mm for elementary geometrical shape RSA. The precision for retroversion was 1.3° for elementary geometrical shape RSA, approximately 2-fold greater than that for the other methods. The intraclass correlation coefficient between the marker-based systems and elementary geometrical shape RSA was approximately 0.5 for retroversion. All 3 methods yielded ICCs for subsidence and varus-valgus rotation above 0.9. We found an excellent correlation between marker-based RSA and elementary geometrical shape RSA for subsidence and varus-valgus rotation, independent of the system used. The precisions for out-of-plane migration were inferior for elementary geometrical shape RSA. Therefore, as a mechanism of failure, retroversion may be more difficult to detect early. This is to our knowledge the first study to compare different RSA systems with or without markers on the implant. Marker-based RSA has high precision in all planes, independent of the system used. Elementary geometrical shape RSA is inferior in out-of-plane migration. Copyright © 2014 Elsevier Ltd. All rights reserved.
Gupta, Rahul; Audhkhasi, Kartik; Lee, Sungbok; Narayanan, Shrikanth
2017-01-01
Non-verbal communication involves encoding, transmission and decoding of non-lexical cues and is realized using vocal (e.g. prosody) or visual (e.g. gaze, body language) channels during conversation. These cues perform the function of maintaining conversational flow, expressing emotions, and marking personality and interpersonal attitude. In particular, non-verbal cues in speech such as paralanguage and non-verbal vocal events (e.g. laughters, sighs, cries) are used to nuance meaning and convey emotions, mood and attitude. For instance, laughters are associated with affective expressions while fillers (e.g. um, ah, um) are used to hold floor during a conversation. In this paper we present an automatic non-verbal vocal events detection system focusing on the detect of laughter and fillers. We extend our system presented during Interspeech 2013 Social Signals Sub-challenge (that was the winning entry in the challenge) for frame-wise event detection and test several schemes for incorporating local context during detection. Specifically, we incorporate context at two separate levels in our system: (i) the raw frame-wise features and, (ii) the output decisions. Furthermore, our system processes the output probabilities based on a few heuristic rules in order to reduce erroneous frame-based predictions. Our overall system achieves an Area Under the Receiver Operating Characteristics curve of 95.3% for detecting laughters and 90.4% for fillers on the test set drawn from the data specifications of the Interspeech 2013 Social Signals Sub-challenge. We perform further analysis to understand the interrelation between the features and obtained results. Specifically, we conduct a feature sensitivity analysis and correlate it with each feature's stand alone performance. The observations suggest that the trained system is more sensitive to a feature carrying higher discriminability with implications towards a better system design. PMID:28713197
21 CFR 876.1725 - Gastrointestinal motility monitoring system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Gastrointestinal motility monitoring system. 876... Gastrointestinal motility monitoring system. (a) Identification. A gastrointestinal motility monitoring system is a... esophageal motility monitor and tube, the gastrointestinal motility (electrical) system, and certain...
21 CFR 876.1725 - Gastrointestinal motility monitoring system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gastrointestinal motility monitoring system. 876... Gastrointestinal motility monitoring system. (a) Identification. A gastrointestinal motility monitoring system is a... esophageal motility monitor and tube, the gastrointestinal motility (electrical) system, and certain...
Multi-emitter laser multiplexer using a two-mirror beam shaper
NASA Astrophysics Data System (ADS)
Cobb, Joshua M.; Brennan, John; Bhatia, Vikram
2014-12-01
A system was designed and built to spatially multiplex four broad area laser diodes (BALD) and condense the light into a multi-mode fiber with a core diameter of 105 um and an NA of 0.15. The lasers were efficiently combined with an étendue aspect ratio scaler (EARS) optic. The EARS works under the principle of a two mirror beam shaper. We were able to successfully couple more than 87% of the optical energy into the fiber. The design of the optical system and the results of several built systems are discussed.
NASA Astrophysics Data System (ADS)
Li, Gaoming; Li, Haijun; Duan, Xiyu; Zhou, Quan; Zhou, Juan; Oldham, Kenn R.; Wang, Thomas D.
2017-02-01
We demonstrate a dual axes confocal architecture, which can be used to collect horizontal(XY-plane) or vertical cross-sectional(XZ-plane) images for tissue. This scanner head is 5.5mm in outer diameter(OD), and integrates a 3D MEMS scanner with a compact chip size of 3.2×2.9mm2. To realize the miniaturization, there are some obstacles of the small size of 3D MEMS scanner, MEMS wire bundle, the air pressure effect for MEMS motion, the processing of parabolic mirror, and optical alignment to come over. In our probe, separation mechanical structure for optical alignment was adopted and a step shape MEMS holder was designed to deal with the difficult of MEMS wire bundle. Peptides have been demonstrated tremendous potential for in vivo use to detect colonic dysplasia. This class of in vivo molecular probe can be labeled with near-infrared (NIR) dyes for visualizing the full depth of the epithelium in small animals. To confirm our probe performance, we take use of USAF 1951 resolution target to test its lateral and axial resolution. It has lateral and axial resolution of 2.49um and 4.98um, respectively. When we collect the fluorescence imaging of colon, it shows that the field of view are 1000um×1000um (horizontal) and 1000um×430um (vertical). The horizontal and vertical cross-sectional images of fresh mouse colonic mucosa demonstrate imaging performance with this miniature instrument.
Smart health monitoring systems: an overview of design and modeling.
Baig, Mirza Mansoor; Gholamhosseini, Hamid
2013-04-01
Health monitoring systems have rapidly evolved during the past two decades and have the potential to change the way health care is currently delivered. Although smart health monitoring systems automate patient monitoring tasks and, thereby improve the patient workflow management, their efficiency in clinical settings is still debatable. This paper presents a review of smart health monitoring systems and an overview of their design and modeling. Furthermore, a critical analysis of the efficiency, clinical acceptability, strategies and recommendations on improving current health monitoring systems will be presented. The main aim is to review current state of the art monitoring systems and to perform extensive and an in-depth analysis of the findings in the area of smart health monitoring systems. In order to achieve this, over fifty different monitoring systems have been selected, categorized, classified and compared. Finally, major advances in the system design level have been discussed, current issues facing health care providers, as well as the potential challenges to health monitoring field will be identified and compared to other similar systems.
NASA Astrophysics Data System (ADS)
Hand, K. P.; Calrson, R.; Sun, H.; Anderson, M.; Wynn, W.; Levy, R.
2005-12-01
We have analyzed both the surface expression and depth profile of cryptoendolithic microbial communities at Battleship Promontory, in the Dry Valleys of Antarctica. Data was collected on site with an active mid-infrared Fourier transform microspectrometer (2.6 - 15 um), a near-infrared spectrometer (0.9-1.8 um), and a visible spectrometer (0.4-1 um). The trio of instruments are connected to microscopes that yield ~1 mm2 spatial resolution on the sample and they are mounted on two perpendicular motorized stages that allow for spatial scanning over an area of ~2cm2. Here we present results on the surface expression of the subsurface microbes in these three spectral regions and we present results on the analysis of a colonized sample examined in cross section. The former case has direct application to the remote, robotic detection of life within the rocks of Mars and the later case provides fundamental insights into the geological and biological interactions that make the Antarctic cryptoendolithic ecosystems possible. Non-invasive surface detection of cyanobacterial dominated communities was possible through the observation of several distinct bands: the carbon-hydrogen stretching modes (symmetric and asymmetric) for CH, CH2, and CH3 in the regions of 3.3-3.6 um and 3.6-3.7 um; the NH2 scissoring and C=O stretch near 6.0 um; the amide I of beta-pleated structures at ~6.1 um; and the 6.4 um - 6.6 um bands of N-H in plane bend of the amide II functional group. In combination, these bands make a strong case for carbohydrates and proteins associated with life. Not surprisingly, as the integrity of the amorphous silica surface varnish improved, our ability to detected the subsurface biosignature decreased. We note, however, that by utilizing the JPL rock crusher in Antarctica, a device designed to fly on the Mars Science Laboratory mission, the mid-infrared biosignature was easily detected. In the cross-section analysis the mid-infrared data provide a depth profile tracking the presence of hydrocarbons, amide bonds, and the mineralogical transition from amorphous quartz to crystalline sandstone. Mapped onto this are the changes in the oxidation states of iron, as recorded by the visible and near-infrared spectrometers. Together, this data set allows us to track the role of biologically produced compounds, such as oxalic acid, in the chelation and leaching of iron compounds from the surface through the rock and into the deposition zone below the colonized subsurface region.
40 CFR 60.2941 - What is my schedule for evaluating continuous emission monitoring systems?
Code of Federal Regulations, 2011 CFR
2011-07-01
... continuous emission monitoring systems? 60.2941 Section 60.2941 Protection of Environment ENVIRONMENTAL... emission monitoring systems? (a) Conduct annual evaluations of your continuous emission monitoring systems... emission monitoring systems daily and quarterly as specified in appendix F of this part. ...
Development of an unmanned maritime system reference architecture
NASA Astrophysics Data System (ADS)
Duarte, Christiane N.; Cramer, Megan A.; Stack, Jason R.
2014-06-01
The concept of operations (CONOPS) for unmanned maritime systems (UMS) continues to envision systems that are multi-mission, re-configurable and capable of acceptable performance over a wide range of environmental and contextual variability. Key enablers for these concepts of operation are an autonomy module which can execute different mission directives and a mission payload consisting of re-configurable sensor or effector suites. This level of modularity in mission payloads enables affordability, flexibility (i.e., more capability with future platforms) and scalability (i.e., force multiplication). The modularity in autonomy facilitates rapid technology integration, prototyping, testing and leveraging of state-of-the-art advances in autonomy research. Capability drivers imply a requirement to maintain an open architecture design for both research and acquisition programs. As the maritime platforms become more stable in their design (e.g. unmanned surface vehicles, unmanned underwater vehicles) future developments are able to focus on more capable sensors and more robust autonomy algorithms. To respond to Fleet needs, given an evolving threat, programs will want to interchange the latest sensor or a new and improved algorithm in a cost effective and efficient manner. In order to make this possible, the programs need a reference architecture that will define for technology providers where their piece fits and how to successfully integrate. With these concerns in mind, the US Navy established the Unmanned Maritime Systems Reference Architecture (UMS-RA) Working Group in August 2011. This group consists of Department of Defense and industry participants working the problem of defining reference architecture for autonomous operations of maritime systems. This paper summarizes its efforts to date.
Combined two-photon microscopy and optical coherence tomography using individually optimized sources
NASA Astrophysics Data System (ADS)
Jeong, Bosu; Lee, Byunghak; Jang, Min Seong; Nam, Hyoseok; Kim, Hae Koo; Yoon, Sang June; Doh, Junsang; Lee, Sang-Joon; Yang, Bo-Gie; Jang, Myoung Ho; Kim, Ki Hean
2011-03-01
Two-photon microscopy (TPM) and optical coherence tomography (OCT) are 3D tissue imaging techniques based on different contrast mechanisms. We developed a combined system of TPM and OCT to provide information of both imaging modalities for in-vivo tissue study. TPM and OCT were implemented by using separate light sources, a Ti-Sapphire laser and a wavelength-swept source centered at 1300 nm respectively, and scanners. Light from the two sources was combined for the simultaneous imaging of tissue samples. TPM provided molecular, cellular information of tissues in the region of a few hundred microns on one side at a sub-cellular resolution, and ran at approximately 40 frames per second. OCT provided structural information in the tissue region larger than TPM images at a sub-tenth micron resolution by using 0.1 numerical aperture. OCT had the field of view of 800 um × 800 um based on a 20x objective, the sensitivity of 97dB, and the imaging speed of 0.8 volumes per second. This combined system was tested with simple microsphere specimens, and then was applied to image the explanted intestine of a mouse model and the plant leaves. Morphology and micro-structures of the intestine villi and immune cells within the villi were shown in the intestine image, and chloroplasts and various microstructures of the maize leaves were visualized in 3D by the combined system.
Nieter, Annabel; Kelle, Sebastian; Takenberg, Meike; Linke, Diana; Bunzel, Mirko; Popper, Lutz; Berger, Ralf G
2016-10-15
Ustilago maydis, an edible mushroom growing on maize (Zea mays), is consumed as the food delicacy huitlacoche in Mexico. A chlorogenic acid esterase from this basidiomycete was expressed in good yields cultivating the heterologous host Pichia pastoris on the 5L bioreactor scale (reUmChlE; 45.9UL(-1)). In contrast to previously described chlorogenic acid esterases, the reUmChlE was also active towards feruloylated saccharides. The enzyme preferred substrates with the ferulic acid esterified to the O-5 position of arabinose residues, typical of graminaceous monocots, over the O-2 position of arabinose or the O-6 position of galactose residues. Determination of kcat/Km showed that the reUmChlE hydrolyzed chlorogenic acid 18-fold more efficiently than methyl ferulate, p-coumarate or caffeate. Phenolic acids were released by reUmChlE from natural substrates, such as destarched wheat bran, sugar beet pectin and coffee pulp. Treatment of wheat dough using reUmChlE resulted in a noticeable softening indicating a potential application of the enzyme in bakery and confectionery. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Lu, Xuecong; Moeini, Mohammad; Li, Baoqiang; Zhang, Cong; Sakadžić, Sava; Lesage, Frédéric
2018-02-01
Cardiovascular risk factors, such as hypertension, have been associated with cognitive decline, potentially due to their impact on brain tissue oxygenation. In this study, high spatial resolution imaging in three dimensions was used to understand changes in brain oxygenation with hypertension. Experiments were performed on Young (WT_Y, 3-4 months, n=8), Old (WT_O, 6-7 months, n=8), and Old with hypertension (HP_O, 6-7 months, n=8) C57bL/6 awake mice. Two photon phosphorescence lifetime microscopy using an O2-sensitive phosphorescent dye PtPC343 was employed to measure two dimensional grids of PO2 in capillary beds (400um*400um, 25*25 pixels, acquired in 4 mins) and decays from arterioles. Scans were obtained continuously at depths from 50 um to 300 um under the brain surface. Using 3D measurements and a 250 um depth stack, we removed the compounding effects on brain oxygenation diffusion from surrounding brain vessels. The entire measurement of each vasculature stack required less than 30 minutes. This study indicates that among vascular risk factors, hypertension can reduce oxygen delivery and could potentially contribute to cognition decline.
Spitzer/IRS spectroscopy of the 12um Seyferts
NASA Astrophysics Data System (ADS)
Wu, Yanling; Charmandaris, V.; Huang, J.; Houck, J.
2009-01-01
The extended 12um galaxy sample is a flux-limited sample of 893 galaxies selected from the IRAS Faint Source Catalog 2. A total of 118 objects from this sample have been classified optically as Seyfert galaxies, providing one of the largest infrared selected unbiased sample of active galactic nuclei (AGN). We present our prelimary results from our analysis of mid-infrared Spitzer/IRS spectra of 102 12um Seyferts (that is 86 % of the 12um Seyfert sample) which have been observed by various Spitzer programs and are available in the Spitzer archive. A number of mid-infared diagnostics have been developed to study the nature of nuclear dust enshrouded emission from AGNs, in order to disentangle the starburst-AGN connection. Since PAH emission is a tracer of star formation activity we have measured the 11.3um PAH feature for our Seyfert sample. We find that as the strength of the radiation field in AGNs increases the PAH molecules are destroyed, while the PAH EWs increase with the IRAS f60/f25 ratios of the host galaxies. We further probe this warm/cold color diagnostic, by contrasting our findings with those of we starbust galaxies, ULIRGs, as well as blue compact dwarf galaxies.
30 CFR 27.21 - Methane-monitoring system.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Methane-monitoring system. 27.21 Section 27.21... APPROVAL OF MINING PRODUCTS METHANE-MONITORING SYSTEMS Construction and Design Requirements § 27.21 Methane-monitoring system. (a) A methane-monitoring system shall be so designed that any machine or equipment, which...
30 CFR 27.21 - Methane-monitoring system.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Methane-monitoring system. 27.21 Section 27.21... APPROVAL OF MINING PRODUCTS METHANE-MONITORING SYSTEMS Construction and Design Requirements § 27.21 Methane-monitoring system. (a) A methane-monitoring system shall be so designed that any machine or equipment, which...
30 CFR 27.21 - Methane-monitoring system.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Methane-monitoring system. 27.21 Section 27.21... APPROVAL OF MINING PRODUCTS METHANE-MONITORING SYSTEMS Construction and Design Requirements § 27.21 Methane-monitoring system. (a) A methane-monitoring system shall be so designed that any machine or equipment, which...
30 CFR 27.21 - Methane-monitoring system.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Methane-monitoring system. 27.21 Section 27.21... APPROVAL OF MINING PRODUCTS METHANE-MONITORING SYSTEMS Construction and Design Requirements § 27.21 Methane-monitoring system. (a) A methane-monitoring system shall be so designed that any machine or equipment, which...
30 CFR 27.21 - Methane-monitoring system.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Methane-monitoring system. 27.21 Section 27.21... APPROVAL OF MINING PRODUCTS METHANE-MONITORING SYSTEMS Construction and Design Requirements § 27.21 Methane-monitoring system. (a) A methane-monitoring system shall be so designed that any machine or equipment, which...
Preamplifiers for non-contact capacitive biopotential measurements*
Peng, GuoChen; Ignjatovic, Zeljko; Bocko, Mark F.
2014-01-01
Non-contact biopotential sensing is an attractive measurement strategy for a number of health monitoring applications, primarily the ECG and the EEG. In all such applications a key technical challenge is the design of a low-noise trans-impedance preamplifier for the typically low-capacitance, high source impedance sensing electrodes. In this paper, we compare voltage and charge amplifier designs in terms of their common mode rejection ratio, noise performance, and frequency response. Both amplifier types employ the same operational-transconductance amplifier (OTA), which was fabricated in a 0.35um CMOS process. The results show that a charge amplifier configuration has advantages for small electrode-to-subject coupling capacitance values (less than 10 pF - typical of noncontact electrodes) and that the voltage amplifier configuration has advantages for electrode capacitances above 10 pF. PMID:24109979
NASA Astrophysics Data System (ADS)
Hong, Wei; Wang, Shaoping; Liu, Haokuo; Tomovic, Mileta M.; Chao, Zhang
2017-01-01
The inductive debris detection is an effective method for monitoring mechanical wear, and could be used to prevent serious accidents. However, debris detection during early phase of mechanical wear, when small debris (<100 um) is generated, requires that the sensor has high sensitivity with respect to background noise. In order to detect smaller debris by existing sensors, this paper presents a hybrid method which combines Band Pass Filter and Correlation Algorithm to improve sensor signal-to-noise ratio (SNR). The simulation results indicate that the SNR will be improved at least 2.67 times after signal processing. In other words, this method ensures debris identification when the sensor's SNR is bigger than -3 dB. Thus, smaller debris will be detected in the same SNR. Finally, effectiveness of the proposed method is experimentally validated.
2008-04-26
substrate Si3N4 Diameter : 540 nm Pitch : 760 nm Diamond Holes in Diamond (HID) Pillars of Diamond (POD) POD with Electrooptic Polymer at Center 3D ...Diamond film : 2 um Si- substrate Al : 0.2 um PMMA : 0.5um 1. Deposit UNCD film 2. Deposit Al metal 3. Deposit PMMA on Al 4. E-beam Lithography 5...band-gap (PBG) based cavities. The cavities are etched directly on to the diamond substrate . The set of coupled qubits in each spot represents an
Direct hip joint distraction during acetabular fracture surgery using the AO universal manipulator.
Calafi, L Afshin; Routt, M L Chip
2010-02-01
Certain acetabular fractures may necessitate distraction of the hip joint for removal of intra-articular debris and assessment of reduction. Distraction can be accomplished by manual traction, using a traction table or an AO universal manipulator (UM). The UM is a relatively simple and an inexpensive device that can provide focal distraction in a controlled manner without the risks associated with the use of a traction table. We describe a technique using the UM for hip joint distraction during acetabular fracture surgery through a Kocher-Langenbeck surgical exposure.
Yusof, Zamros Y M; Hassan, Wan Nurazreena Wan; Razak, Ishak A; Hashim, Siti Marini N; Tahir, Mohd Khairul A M; Keng, Siong Beng
2016-11-01
This study aimed to evaluate the association between dental students’ personality traits and stress levels in relation to dental education programs among senior dental students in University Malaya (UM) in Malaysia and National University of Singapore (NUS). A cross-sectional survey using a self-administered questionnaire was conducted on UM and NUS senior dental students. The questionnaire comprised items on demographic background, the Big Five Inventory Personality Traits (BFIPT) test and a modified Dental Environment Stress (DES) scale. Rasch analysis was used to convert raw data to interval scores. Analyses were done by t-test, Pearson correlation, and Hierarchical regression statistics. The response rate was 100% (UM=132, NUS=76). Personality trait Agreeableness (mean=0.30) was significantly more prevalent among UM than NUS students (mean=0.15, p=0.016). In NUS, Neuroticism (mean=0.36) was significantly more prevalent than in UM (mean=0.14, p=0.002). The DES mean score was higher among NUS (mean=0.23) than UM students (mean=0.07). In UM, Neuroticism was significantly correlated with stress levels (r=0.338, p<0.001). In NUS, these were Neuroticism (r=0.278, p=0.015), Agreeableness (r=0.250, p=0.029) and Conscientiousness (r=-0.242, p=0.035) personality traits. The correlation was strongest for personality trait Neuroticism in both schools. Hierarchical regression analysis showed that gender and Neuroticism were significant predictors for students’ stress levels (p<0.05) with the latter exerting a bigger effect size (R2=0.18) than gender (R2=004). This study showed that gender and Neuroticism personality trait were significant predictors for stress levels among selected groups of dental students in Southeast Asia. Information on students’ personality may be useful in new students’ intake, stress management counseling and future program reviews.
An indirect continuous running multistage field test: the Université de Montréal track test.
Léger, L; Boucher, R
1980-06-01
The object of this study was to report on the validity and reliability of the Université de Montréal Track Test (UM-TT). The UM-TT is a continuous maximal indirect multistage running field test based on the energy cost of running. The first stage is set at a walking speed that requires 5 Mets; thereafter the speed is increased by 1 Met every two minutes. In order to assess the validity of the UM-TT, 25 subjects, 24.4 +/- 2.8 years old (X +/- SD) had their VO2max predicted with the UM-TT and measured directly with a running multistage treadmill test. Averages (+/- SD) were not significantly different (61.5 +/- 10.6 and 61.4 +/- 10.9 ml O2 . kg-1 . min-1, respectively), other statistics being r = 0.96, delta = 0.09 +/- 2.90 ml O2 . kg-1 . min-1 and Syx = 2.81 ml O2 . kg-1 . min-1. Seven males, 20.6 +/- 1.0 years old, had also their VO2max measured directly during the UM-TT. Comparison of predicted and directly measured VO2max yielded similar results: 70.0 +/- 4.5 and 70.7 +/- 6.0 ml O2 . kg-1 . min-1, respectively with r = 0.66, delta = 0.67 +/- 4.53 and Syx = 3.71. Reliability of the UM-TT was assessed by repeating the test twice on 60 subjects (49 males and 11 females; 39 subjects below 30 years old and 21, above; and 30 subjects below and above 15 Mets). Results were as follows: X +/- SD = 54.1 +/- 8.2 and 54.2 +/- 8.5, r = 0.97, delta 0.11 +/- 1.92, and Syx = 1.92. Similar reliability trends were observed for each one of the subgroups of subjects. It is concluded that the UM-TT is valid and reliable to estimate the VO2max of trained and untrained young and middle-age males and females.
Long-Term Satisfaction and Body Image After Contralateral Prophylactic Mastectomy
Anderson, Chelsea; Islam, Jessica Y.; Hodgson, M. Elizabeth; Sabatino, Susan A.; Rodriguez, Juan L.; Lee, Clara N.; Sandler, Dale P.; Nichols, Hazel B.
2017-01-01
Background Contralateral prophylactic mastectomy (CPM) rates have been increasing in the U.S. Though some studies have reported high overall satisfaction among women who undergo CPM, it is unclear how long-term satisfaction differs from that of women who undergo unilateral mastectomy (UM). Furthermore, few studies have assessed whether the effects of CPM on body image differ from those of breast conserving surgery (BCS) or UM. Methods We analyzed responses from a survey of women with both a personal and family history of breast cancer who were enrolled in the Sister Study (n=1176). Among women who underwent mastectomy, satisfaction with mastectomy decision and reconstruction was compared between women who underwent CPM and UM. We also evaluated responses on 5 items related to body image according to surgery type (BCS, UM without reconstruction, CPM without reconstruction, UM with reconstruction, and CPM with reconstruction). Results Participants were, on average, 60.8 years old at diagnosis (SD=8.7) and 3.6 years post-diagnosis at the time of survey (SD=1.7). BCS was the most common surgical treatment reported (63%), followed by CPM (22%) and UM (15%). Satisfaction with mastectomy decision was reported by 97% of women who underwent CPM and 89% of those who underwent UM. Compared to other surgery types, women who underwent CPM without reconstruction reported feeling more self-conscious, less feminine, less whole, and less satisfied with the appearance of their breasts. Body image was consistently highest among women who underwent BCS. Conclusions In our sample of women with both a personal and family history of breast cancer, most were highly satisfied with their mastectomy decision, including those who elected to undergo CPM. However, body image was lowest among women who underwent CPM without reconstruction. Our findings may inform decisions among women considering various courses of surgical treatment. PMID:28058563
VizieR Online Data Catalog: Galactic CHaMP. II. Dense gas clumps. (Ma+, 2013)
NASA Astrophysics Data System (ADS)
Ma, B.; Tan, J. C.; Barnes, P. J.
2015-04-01
A total of 303 dense gas clumps have been detected using the HCO+(1-0) line in the CHaMP survey (Paper I, Barnes et al. 2011, J/ApJS/196/12). In this article we have derived the SED for these clumps using Spitzer, MSX, and IRAS data. The Midcourse Space Experiment (MSX) was launched in 1996 April. It conducted a Galactic plane survey (0
Moya, G; Dorado, P; Ferreiro, V; Naranjo, M E G; Peñas-Lledó, E M; LLerena, A
2017-07-01
A twofold higher frequency of CYP2D6 ultrarapid metabolizers (estimated from genotype: gUMs) was reported among Ashkenazi Jews (AJ) living in New York (USA) than in other North American Caucasians, which might be important to guide the prescription for CYP2D6 substrates in AJ communities around the world. This study was aimed to determine whether the high frequency of CYP2D6 gUMs described in AJ from USA was replicated in AJ from Argentina when compared with other multiethnic admixture Argentines (GA). The frequency of the most common allelic variants and of CYP2D6 gUMs (>2 active genes) and poor metabolizers (0 active genes, gPMs) was also compared among the studied Argentine populations. CYP2D6 genotyping was performed in 173 AJ and 246 GA DNA samples of unrelated donors from the metropolitan area of Buenos Aires. CYP2D6 alleles (*2, *3, *4, *5, *6, *10, *17, *35, *41 and multiple copies), genotypes and functional phenotype frequencies were determined. The frequencies of gUMs and gPMs in AJ from Argentina were 11.5% and 5.2%, respectively, whereas in GA, the frequencies of gUM and gPMs were 6.5% and 4.9%, respectively. Comparisons between AJ and GA showed that gUMs frequencies were twofold higher (P<0.05) in AJ than GA. CYP2D6*35 allele was more frequent in GA than AJ, whereas CYP2D6*41 and *1xN were more frequent in AJ than in GA (P<0.05). This study supports the previously reported high frequency of gUMs on another Ashkenazi population in New York. The present findings also support the interethnic variability of CYP2D6 genetic polymorphism in the overall Argentine population.
NASA Astrophysics Data System (ADS)
Ferreyra, R.; Stockle, C. O.; Huggins, D. R.
2014-12-01
Soil water storage and dynamics are of critical importance for a variety of processes in terrestrial ecosystems, including agriculture. Many of those systems are under significant pressure in terms of water availability and use. Therefore, assessing alternative scenarios through hydrological models is an increasingly valuable exercise. Soil water holding capacity is defined by the concepts of soil field capacity and plant available water, which are directly related to soil physical properties. Both concepts define the energy status of water in the root system and closely interact with plant physiological processes. Furthermore, these concepts play a key role in the environmental transport of nutrients and pollutants. Soil physical parameters (e.g. saturated hydraulic conductivity, total porosity and water release curve) are required as input for field-scale soil water redistribution models. These parameters are normally not easy to measure or monitor, and estimation through pedotransfer functions is often inadequate. Our objectives are to improve field-scale hydrological modeling by: (1) assessing new undisturbed methodologies for determining important soil physical parameters necessary for model inputs; and (2) evaluating model outputs, making a detailed specification of soil parameters and the particular boundary condition that are driving water movement under two contrasting environments. Soil physical properties (saturated hydraulic conductivity and determination of water release curves) were quantified using undisturbed laboratory methodologies for two different soil textural classes (silt loam and sandy loam) and used to evaluate two soil water redistribution models (finite difference solution and hourly cascade approach). We will report on model corroboration results performed using in situ, continuous, field measurements with soil water content capacitance probes and digital tensiometers. Here, natural drainage and water redistribution were monitored following a controlled water application where the study areas were isolated from other water inputs and outputs. We will also report on the assessment of two soil water sensors (Decagon Devices 5TM capacitance probe and UMS T4 tensiometers) for the two soil textural classes in terms of consistency and replicability.
VizieR Online Data Catalog: [CII] emission in the ISM of 20 nearby galaxies (Croxall+, 2017)
NASA Astrophysics Data System (ADS)
Croxall, K. V.; Smith, J. D.; Pellegrini, E.; Groves, B.; Bolatto, A.; Herrera-Camus, R.; Sandstrom, K. M.; Draine, B.; Wolfire, M. G.; Armus, L.; Boquien, M.; Brandl, B.; Dale, D.; Galametz, M.; Hunt, L.; Kennicutt, R.; Kreckel, K.; Rigopoulou, D.; van der Werf, P.; Wilson, C.
2018-04-01
Our observations include photometric and spectral-line observations from both the PACS and SPIRE instruments onboard Herschel, obtained as part of the large KINGFISH (Key Insights on Nearby Galaxies: a Far- Infrared Survey with Herschel, Kennicutt+ 2011PASP..123.1347K) and BtP (Beyond the Peak; OT1_jsmith1; P.I. J.D. Smith) projects. [NII]205um BtP observations were performed with SPIRE-FTS intermediate mapping, which is a 4-point dither. E. Pellegrini et al. (2017, in preparation) will contain a full description of the observations and reductions. [CII]158um and [NII]122um emission lines, and 70 and 160um continuum maps have been observed as part the Herschel Open Time Key Program KINGFISH. The data and the associated reduction are described in Kennicutt+ (2011PASP..123.1347K) and Croxall+ (2013ApJ...777...96C). (2 data files).
Development of a compact E ? B microchannel plate detector for beam imaging
Wiggins, B. B.; Singh, Varinderjit; Vadas, J.; ...
2017-06-17
A beam imaging detector was developed by coupling a multi-strip anode with delay line readout to an E×B microchannel plate (MCP) detector. This detector is capable of measuring the incident position of the beam particles in one-dimension. To assess the spatial resolution, the detector was illuminated by an α-source with an intervening mask that consists of a series of precisely-machined slits. The measured spatial resolution was 520 um source FWHM, which was improved to 413 um FWHM by performing an FFT of the signals, rejecting spurious signals on the delay line, and requiring a minimum signal amplitude. This measured spatialmore » resolution of 413 um FWHM corresponds to an intrinsic resolution of 334 um FWHM when the effect of the finite slit width is de-convoluted. To understand the measured resolution, the performance of the detector is simulated with the ion-trajectory code SIMION.« less
Development of a compact E ? B microchannel plate detector for beam imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wiggins, B. B.; Singh, Varinderjit; Vadas, J.
A beam imaging detector was developed by coupling a multi-strip anode with delay line readout to an E×B microchannel plate (MCP) detector. This detector is capable of measuring the incident position of the beam particles in one-dimension. To assess the spatial resolution, the detector was illuminated by an α-source with an intervening mask that consists of a series of precisely-machined slits. The measured spatial resolution was 520 um source FWHM, which was improved to 413 um FWHM by performing an FFT of the signals, rejecting spurious signals on the delay line, and requiring a minimum signal amplitude. This measured spatialmore » resolution of 413 um FWHM corresponds to an intrinsic resolution of 334 um FWHM when the effect of the finite slit width is de-convoluted. To understand the measured resolution, the performance of the detector is simulated with the ion-trajectory code SIMION.« less
Dysregulated GPCR Signaling and Therapeutic Options in Uveal Melanoma
Chua, Vivian; Lapadula, Dominic; Randolph, Clinita; Benovic, Jeffrey L.; Wedegaertner, Philip; Aplin, Andrew E.
2017-01-01
Uveal melanoma (UM) is the most common primary intraocular malignant tumor in adults and arises from the transformation of melanocytes in the uveal tract. Even after treatment of the primary tumor, up to 50% of patients succumb to metastatic disease. The liver is the predominant organ of metastasis. There is an important need to provide effective treatment options for advanced stage UM. In order to provide the preclinical basis for new treatments, it is important to understand the molecular underpinnings of the disease. Recent genomic studies have shown that mutations within components of G protein-coupled receptor (GPCR) signaling are early events associated with ~98% of UMs. Implications This review discusses the alterations in GPCR signaling components (GNAQ and GNA11), dysregulated GPCR signaling cascades, and viable targeted therapies with the intent to provide insight into new therapeutic strategies in UM. PMID:28223438
Thompson, CL; Schulz1, Wade L.; Terrence, Adam
2011-01-01
The University of Minnesota medical student wiki (UMMedWiki) allows students to collaboratively edit classroom notes to support medical education. Since 2007, UMMedWiki has grown to include 1,591 articles that have collectively received 1.2 million pageviews. Although small-scale wikis have become increasingly important, little is known about their dynamics compared to large wikis, such as Wikipedia. To better understand UMMedWiki’s management and its potential reproducibility at other medical schools, we used an edit log with 28,000 entries to evaluate the behavior of its student editors. The development of tools to survey UMMedwiki allows for quality comparisons that improve both the wiki and the curriculum itself. We completed a content survey by comparing the UMMedWiki with two types of rubric data: TIME, a medical education taxonomy consisting of 1500 terms and national epidemiological data on 2,100 diseases. PMID:22195202
40 CFR 60.3038 - What continuous emission monitoring systems must I install?
Code of Federal Regulations, 2011 CFR
2011-07-01
... December 9, 2004 Model Rule-Monitoring § 60.3038 What continuous emission monitoring systems must I install? (a) You must install, calibrate, maintain, and operate continuous emission monitoring systems for... system according to the “Monitoring Requirements” in § 60.13. ...
49 CFR 385.703 - Safety monitoring system.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 5 2010-10-01 2010-10-01 false Safety monitoring system. 385.703 Section 385.703... Safety Monitoring System for Non-North American Carriers § 385.703 Safety monitoring system. (a) General... Vehicle Safety Standards (FMVSSs), and Hazardous Materials Regulations (HMRs). (b) Roadside monitoring...
49 CFR 385.103 - Safety monitoring system.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 5 2010-10-01 2010-10-01 false Safety monitoring system. 385.103 Section 385.103... Safety Monitoring System for Mexico-Domiciled Carriers § 385.103 Safety monitoring system. (a) General... Vehicle Safety Standards (FMVSSs), and Hazardous Materials Regulations (HMRs). (b) Roadside monitoring...
40 CFR 60.3038 - What continuous emission monitoring systems must I install?
Code of Federal Regulations, 2010 CFR
2010-07-01
... December 9, 2004 Model Rule-Monitoring § 60.3038 What continuous emission monitoring systems must I install? (a) You must install, calibrate, maintain, and operate continuous emission monitoring systems for... system according to the “Monitoring Requirements” in § 60.13. ...
49 CFR 385.703 - Safety monitoring system.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 5 2011-10-01 2011-10-01 false Safety monitoring system. 385.703 Section 385.703... Safety Monitoring System for Non-North American Carriers § 385.703 Safety monitoring system. (a) General... Vehicle Safety Standards (FMVSSs), and Hazardous Materials Regulations (HMRs). (b) Roadside monitoring...
49 CFR 385.103 - Safety monitoring system.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 5 2011-10-01 2011-10-01 false Safety monitoring system. 385.103 Section 385.103... Safety Monitoring System for Mexico-Domiciled Carriers § 385.103 Safety monitoring system. (a) General... Vehicle Safety Standards (FMVSSs), and Hazardous Materials Regulations (HMRs). (b) Roadside monitoring...
Nuclear Weapons Effects on Army Tactical Systems. Volume 1. Overview
1979-04-01
UNCLASSI I I E >D ICV.RI , CLAISGFICAIO04 or TRIS v f, I t’,, *I tn, ) REPORT DOCUMENTATION PAGE ..... ro"..,T.UV IOR REP041 UM"ER . oOVI ACCESSION NO...Effects on Archimy. e ~ Tactical System!p- e . -,- o 0. CON . on GRANT NUMBER(., Joseph J. Halpin (also ed.) John P. Swirczynski (also ed.) D 212 112...THIS PAGE(7h"n Va0m Ent..’. E ) FOREWORD This document describes the general insights and the key issues for the nuclear survivability of tactical
1998-04-17
concerns center around its ultimate goal to maximize appropriate care and minimize or eliminate inappropriate care (DoD UM Policy , 1996). While the...uasp cncd . GCK Tobacco taw disorder tr’O: Anemia ID: Acute bronchial ID: A«Jtt]ihiir<rtiK*i» 10: Acute refft iafection ID: Acute xinucm ID...181-187. Department of Defense (DoD) Ultilization Management Policy for the Direct Care System (Draft) (1996). Duncan, D.G. & Servais, C.S., (1996
1975-05-20
across the anode side of the membrane -electrode assembly. Flow distribution of the hydrogen gas from cell to cell is not a problem as that system is...DOCUMENTATION PAGE RiEAI T C OMPLETING FORM V ~i 12.BR NUMVE AccEisioN NO4 II T AAO UM811" 4. TITL[ (Wd SibItl@) ... . I YPE or REPORT I PERIOD COVERED...instructions for Fuel Cell Module FS-2. The ion exchange membrane fuel cell module is produced by the General Electric Company, Direct Energy
Wee, Wei Yee; Tan, Tze King; Jakubovics, Nicholas S; Choo, Siew Woh
2016-01-01
Mycobacterium brisbanense is a member of Mycobacterium fortuitum third biovariant complex, which includes rapidly growing Mycobacterium spp. that normally inhabit soil, dust and water, and can sometimes cause respiratory tract infections in humans. We present the first whole-genome analysis of M. brisbanense UM_WWY which was isolated from a 70-year-old Malaysian patient. Molecular phylogenetic analyses confirmed the identification of this strain as M. brisbanense and showed that it has an unusually large genome compared with related mycobacteria. The large genome size of M. brisbanense UM_WWY (~7.7Mbp) is consistent with further findings that this strain has a highly variable genome structure that contains many putative horizontally transferred genomic islands and prophage. Comparative analysis showed that M. brisbanense UM_WWY is the only Mycobacterium species that possesses a complete set of genes encoding enzymes involved in the urea cycle, suggesting that this soil bacterium is able to synthesize urea for use as plant fertilizers. It is likely that M. brisbanense UM_WWY is adapted to live in soil as its primary habitat since the genome contains many genes associated with nitrogen metabolism. Nevertheless, a large number of predicted virulence genes were identified in M. brisbanense UM_WWY that are mostly shared with well-studied mycobacterial pathogens such as Mycobacterium tuberculosis and Mycobacterium abscessus. These findings are consistent with the role of M. brisbanense as an opportunistic pathogen of humans. The whole-genome study of UM_WWY has provided the basis for future work of M. brisbanense.
Morita, Wataru; Yano, Wataru; Nagaoka, Tomohito; Abe, Mikiko; Ohshima, Hayato; Nakatsukasa, Masato
2014-01-01
Tooth crown patterning is governed by the growth and folding of the inner enamel epithelium (IEE) and the following enamel deposition forms outer enamel surface (OES). We hypothesized that overall dental crown shape and covariation structure are determined by processes that configurate shape at the enamel–dentine junction (EDJ), the developmental vestige of IEE. This this hypothesis was tested by comparing patterns of morphological variation between EDJ and OES in human permanent maxillary first molar (UM1) and deciduous second molar (um2). Using geometric morphometric methods, we described morphological variation and covariation between EDJ and OES, and evaluated the strength of two components of phenotypic variability, canalization and morphological integration, in addition to the relevant evolutionary flexibility, i.e. the ability to respond to selective pressure. The strength of covariation between EDJ and OES was greater in um2 than in UM1, and the way that multiple traits covary between EDJ and OES was different between these teeth. The variability analyses showed that EDJ had less shape variation and a higher level of morphological integration than OES, which indicated that canalization and morphological integration acted as developmental constraints. These tendencies were greater in UM1 than in um2. On the other hand, EDJ and OES had a comparable level of evolvability in these teeth. Amelogenesis could play a significant role in tooth shape and covariation structure, and its influence was not constant among teeth, which may be responsible for the differences in the rate and/or period of enamel formation. PMID:24689536
Clinical analysis of a large kindred with the pallister ulnar-mammary syndrome
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bamshad, M.; Root, S.; Carey, J.C.
1996-11-11
The ulnar-mammary syndrome (UMS) is an autosomal dominant disorder characterized by posterior limb deficiencies or duplications, apocrine/mammary gland hypoplasia and/or dysfunction, abnormal dentition, delayed puberty in males, and genital anomalies. We present the clinical descriptions of 33 members of a six generation kindred with UMS. The number of affected individuals in this family is more than the sum of all previously reported cases of UMS. The clinical expression of UMS is highly variable. While most patients have limb deficiencies, the range of abnormalities extends from hypoplasia of the terminal phalanx of the 5th digit to complete absence of the ulnamore » and 3rd, 4th, and 5th digits. Moreover, affected individuals may have posterior digital duplications with or without contralateral limb deficiencies. Apocrine gland abnormalities range from diminished axillary perspiration with normal breast development and lactation, to complete absence of the breasts and no axillary perspiration. Dental abnormalities include misplaced or absent teeth. Affected males consistently undergo delayed puberty, and both sexes have diminished to absent axillary hair. Imperforate hymen were seen in some affected women. A gene for UMS was mapped to chromosome area 12q23-q24.1. A mutation in the gene causing UMS can interfere with limb patterning in the proximal/distal, anterior/posterior, and dorsal/ventral axes. This mutation disturbs development of the posterior elements of forearm, wrist, and hand while growth and development of the anterior elements remain normal. 24 refs., 4 figs., 1 tab.« less
VCSEL-based optical transceiver module operating at 25 Gb/s and using a single CMOS IC
NASA Astrophysics Data System (ADS)
Afriat, Gil; Horwitz, Lior; Lazar, Dror; Issachar, Assaf; Pogrebinsky, Alexander; Ran, Adee; Shoor, Ehud; Bar, Roi; Saba, Rushdy
2012-01-01
We present here a low cost, small form factor, optical transceiver module composed of a CMOS IC transceiver, 850 nm emission wavelength VCSEL modulated at 25 Gb/s, and an InGaAs/InP PIN Photo Diode (PD). The transceiver IC is fabricated in a standard 28 nm CMOS process and integrates the analog circuits interfacing the VCSEL and PD, namely the VCSEL driver and Transimpedance Amplifier (TIA), as well as all other required transmitter and receiver circuits like Phase Locked Loop (PLL), Post Amplifier and Clock & Data Recovery (CDR). The transceiver module couples into a 62.5/125 um multi-mode (OM1) TX/RX fiber pair via a low cost plastic cover realizing the transmitter and receiver lens systems and demonstrates BER < 10-12 at the 25 Gb/s data rate over a distance of 3 meters. Using a 50/125 um laser optimized multi-mode fiber (OM3), the same performance was achieved over a distance of 30 meters.
Visible-light vertical-cavity surface-emitting lasers grown by solid-source molecular beam epitaxy
NASA Astrophysics Data System (ADS)
Saarinen, Mika J.; Xiang, Ning; Dumitrescu, Mihail M.; Vilokkinen, Ville; Melanen, Petri; Orsila, Seppo; Uusimaa, Petteri; Savolainen, Pekka; Pessa, Markus
2001-05-01
Visible vertical-cavity surface-emitting lasers (VCSELs) are potential light sources for polymer optical fibre (POF) data transmission systems. Minimum attenuation of light in standard PMMA-POFs occurs at about 650 nm. For POFs of a few tens of meters in length VCSELs at slightly longer wavelengths (670 - 690 nm) are also acceptable. So far, the visible VCSELs have been grown by metal organic chemical vapour deposition (MOCVD). They may also be grown by a novel variant of molecular beam epitaxy (MBE), a so-called all-solid-source MBE or SSMBE. In this paper, we describe growth of the first visible-light VCSELs by SSMBE and present the main results obtained. In particular, we have achieved lasing action at a sub-milliamp cw drive current for a VCSEL having the emission window of 8um in diameter, while a 10um device exhibited an external quantum efficiency of 6.65% in CW operation at room temperature. The lasing action up to temperature of 45°C has been demonstrated.
29 CFR 1954.2 - Monitoring system.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 29 Labor 9 2014-07-01 2014-07-01 false Monitoring system. 1954.2 Section 1954.2 Labor Regulations...) PROCEDURES FOR THE EVALUATION AND MONITORING OF APPROVED STATE PLANS General § 1954.2 Monitoring system. (a... Act, the Assistant Secretary has established a State Program Performance Monitoring System. Evaluation...
29 CFR 1954.2 - Monitoring system.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 29 Labor 9 2013-07-01 2013-07-01 false Monitoring system. 1954.2 Section 1954.2 Labor Regulations...) PROCEDURES FOR THE EVALUATION AND MONITORING OF APPROVED STATE PLANS General § 1954.2 Monitoring system. (a... Act, the Assistant Secretary has established a State Program Performance Monitoring System. Evaluation...
29 CFR 1954.2 - Monitoring system.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 29 Labor 9 2012-07-01 2012-07-01 false Monitoring system. 1954.2 Section 1954.2 Labor Regulations...) PROCEDURES FOR THE EVALUATION AND MONITORING OF APPROVED STATE PLANS General § 1954.2 Monitoring system. (a... Act, the Assistant Secretary has established a State Program Performance Monitoring System. Evaluation...
29 CFR 1954.2 - Monitoring system.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 29 Labor 9 2010-07-01 2010-07-01 false Monitoring system. 1954.2 Section 1954.2 Labor Regulations...) PROCEDURES FOR THE EVALUATION AND MONITORING OF APPROVED STATE PLANS General § 1954.2 Monitoring system. (a... Act, the Assistant Secretary has established a State Program Performance Monitoring System. Evaluation...
29 CFR 1954.2 - Monitoring system.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 29 Labor 9 2011-07-01 2011-07-01 false Monitoring system. 1954.2 Section 1954.2 Labor Regulations...) PROCEDURES FOR THE EVALUATION AND MONITORING OF APPROVED STATE PLANS General § 1954.2 Monitoring system. (a... Act, the Assistant Secretary has established a State Program Performance Monitoring System. Evaluation...
40 CFR 60.3040 - What is my schedule for evaluating continuous emission monitoring systems?
Code of Federal Regulations, 2011 CFR
2011-07-01
... continuous emission monitoring systems? 60.3040 Section 60.3040 Protection of Environment ENVIRONMENTAL... continuous emission monitoring systems? (a) Conduct annual evaluations of your continuous emission monitoring... emission monitoring systems daily and quarterly as specified in appendix F of this part. ...
40 CFR 60.2939 - What continuous emission monitoring systems must I install?
Code of Federal Regulations, 2010 CFR
2010-07-01
... and Qualification Monitoring § 60.2939 What continuous emission monitoring systems must I install? (a) You must install, calibrate, maintain, and operate continuous emission monitoring systems for carbon... carbon monoxide. (b) You must install, evaluate, and operate each continuous emission monitoring system...
40 CFR 60.2939 - What continuous emission monitoring systems must I install?
Code of Federal Regulations, 2011 CFR
2011-07-01
... and Qualification Monitoring § 60.2939 What continuous emission monitoring systems must I install? (a) You must install, calibrate, maintain, and operate continuous emission monitoring systems for carbon... carbon monoxide. (b) You must install, evaluate, and operate each continuous emission monitoring system...
Wireless patient monitoring system for a moving-actuator type artificial heart.
Nam, K W; Chung, J; Choi, S W; Sun, K; Min, B G
2006-10-01
In this study, we developed a wireless monitoring system for outpatients equipped with a moving-actuator type pulsatile bi-ventricular assist device, AnyHeart. The developed monitoring system consists of two parts; a Bluetooth-based short-distance self-monitoring system that can monitor and control the operating status of a VAD using a Bluetooth-embedded personal digital assistant or a personal computer within a distance of 10 meters, and a cellular network-based remote monitoring system that can continuously monitor and control the operating status of AnyHeart at any location. Results of in vitro experiments demonstrate the developed system's ability to monitor the operational status of an implanted AnyHeart.
Hayes, Michael C.; Rubin, Stephen P.; Hensleigh, Jay E.; Reisenbichler, Reginald R.; Wetzel, Lisa A.
2005-01-01
Despite the expanding use of milt cryopreservation in aquaculture, the performance of fish produced from this technique has not been fully explored beyond initial rearing stages. We compared the performance of juvenile steelhead Oncorhynchus mykiss produced from untreated (UM) and cryopreserved milt (CM) and reared for 4–9 months. For the 1996 brood, CM alevins were heavier (∼ 1.7%, P < 0.01) than UM alevins and length was influenced by a significant milt-by-family interaction (P < 0.03) suggesting a greater treatment effect for some families. No significant differences were found in length or weight (P > 0.05) for 1997 brood alevins and percent yolk was similar for both broods (P > 0.34). In growth and survival experiment I (GSE-I, 1996), UM and CM juveniles reared in separate tanks and fed to satiation (130 days) showed no significant differences in survival, length or weight (P > 0.05) between milt groups. In contrast, for UM and CM siblings reared in the same tank for 210 days on a low food ration (GSE-II), survival was similar (P > 0.05), but length (UM 4% > CM, P < 0.05) and possibly weight (UM 15% > CM, P = 0.08), were influenced by cryopreservation. Fish from the 1997 brood (GSE-III) were reared for 313 days in a repeat of GSE-II and no differences were found in survival (P = 0.47), length (P = 0.75) or weight (P = 0.76) suggesting considerable heterogeneity between broods. Performance of the 1996 brood was also tested for response to stress and a disease challenge. Cortisol responses of juveniles exposed to acute stress were not significantly different (P = 0.19), but mean cortisol was consistently and significantly greater (P < 0.01) for CM than UM fish exposed to a 48-h stress (increased density). After exposure to three dosages of the bacteria, Listonella anguillarum, we found similar mortality proportions (P = 0.72) for UM and CM fish. Variable juvenile performance for the parameters tested indicated significant differences among broods and families and suggests a cautionary approach to the widespread use of cryopreservation for steelhead.
Initiation of the TLR4 signal transduction network : deeper understanding for better therapeutics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Branda, Steven S.; Hayden, Carl C.; Sherman, Michael Y.
2010-09-01
The innate immune system represents our first line of defense against microbial pathogens, and in many cases is activated by recognition of pathogen cellular components (dsRNA, flagella, LPS, etc.) by cell surface membrane proteins known as toll-like receptors (TLRs). As the initial trigger for innate immune response activation, TLRs also represent a means by which we can effectively control or modulate inflammatory responses. This proposal focused on TLR4, which is the cell-surface receptor primarily responsible for initiating the innate immune response to lipopolysaccharide (LPS), a major component of the outer membrane envelope of gram-negative bacteria. The goal was to bettermore » understand TLR4 activation and associated membrane proximal events, in order to enhance the design of small molecule therapeutics to modulate immune activation. Our approach was to reconstitute the receptor in biomimetic systems in-vitro to allow study of the structure and dynamics with biophysical methods. Structural studies were initiated in the first year but were halted after the crystal structure of the dimerized receptor was published early in the second year of the program. Methods were developed to determine the association constant for oligomerization of the soluble receptor. LPS-induced oligomerization was observed to be a strong function of buffer conditions. In 20 mM Tris pH 8.0 with 200 mM NaCl, the onset of receptor oligomerization occurred at 0.2 uM TLR4/MD2 with E coli LPS Ra mutant in excess. However, in the presence of 0.5 uM CD14 and 0.5 uM LBP, the onset of receptor oligomerization was observed to be less than 10 nM TLR4/MD2. Several methods were pursued to study LPS-induced oligomerization of the membrane-bound receptor, including CryoEM, FRET, colocalization and codiffusion followed by TIRF, and fluorescence correlation spectroscopy. However, there approaches met with only limited success.« less
Deehan, Gerald A.; Hauser, Sheketha R.; Waeiss, R. Aaron; Knight, Christopher P.; Toalston, Jamie E.; Truitt, William A.; McBride, William J.; Rodd, Zachary A.
2016-01-01
Rationale The co-abuse of ethanol (EtOH) and nicotine (NIC) increases the likelihood that an individual will relapse to drug-use while attempting to maintain abstinence. There is limited research examining the consequences of long-term EtOH and NIC co-abuse. Objectives The current experiments determined the enduring effects of chronic EtOH, NIC, or EtOH + NIC intake on the reinforcing properties of NIC and glutamate (GLU) activity within the mesocorticolimbic (MCL) system. Methods Alcohol-preferring (P) rats self-administered EtOH, Sacc + NIC or EtOH + NIC combined for 10 weeks. The reinforcing properties of 0.1–3.0 uM NIC within the nucleus accumbens shell (AcbSh) were assessed following a 2–3 week drug-free period using intracranial self-administration (ICSA) procedures. The effects of EtOH, Sacc, Sacc + NIC or EtOH + NIC intake on extracellular levels and clearance of glutamate (GLU) in the medial prefrontal cortex (mPFC) were also determined. Results Binge intake of EtOH (96–100 mg%) and NIC (21–27 mg/ml) were attained. All groups of P rats self-infused 3.0 uM NIC directly into the AcbSh; whereas only animals in the EtOH + NIC co-abuse group self-infused the 0.3 and 1.0 uM NIC concentrations. Additionally, self-administration of EtOH + NIC, but not EtOH, Sacc or Sacc + NIC, resulted in enduring increases in basal extracellular GLU levels in the mPFC. Conclusions Overall, the co-abuse of EtOH + NIC produced enduring neuronal alterations within the MCL which enhanced the rewarding properties of NIC in the AcbSh and elevated extracellular GLU levels within the mPFC. PMID:26306917
Park, Soon-Ung; Lee, In-Hye; Joo, Seung Jin; Ju, Jae-Won
2017-12-01
Site specific radionuclide dispersion databases were archived for the emergency response to the hypothetical releases of 137 Cs from the Uljin nuclear power plant in Korea. These databases were obtained with the horizontal resolution of 1.5 km in the local domain centered the power plant site by simulations of the Lagrangian Particle Dispersion Model (LPDM) with the Unified Model (UM)-Local Data Assimilation Prediction System (LDAPS). The Eulerian Dispersion Model-East Asia (EDM-EA) with the UM-Global Data Assimilation Prediction System (UM-GDAPS) meteorological models was used to get dispersion databases in the regional domain. The LPDM model was performed for a year with a 5-day interval yielding 72 synoptic time-scale cases in a year. For each case hourly mean near surface concentrations, hourly mean column integrated concentrations, hourly total depositions for 5 consecutive days were archived by the LPDM model in the local domain and by the EDM-EA model in the regional domain of Asia. Among 72 synoptic cases in a year the worst synoptic case that showed the highest mean surface concentration averaged for 5 days in the LPDM model domain was chosen to illustrate the emergency preparedness to the hypothetical accident at the site. The simulated results by the LPDM model with the 137 Cs emission rate of the Fukushima nuclear power plant accident for the first 5-day period were found to be able to provide prerequisite information for the emergency response to the early phase of the accident whereas those of the EDM-EA model could provide information required for the environmental impact assessment of the accident in the regional domain. The archived site-specific database of 72 synoptic cases in a year could have a great potential to be used as a prognostic information on the emergency preparedness for the early phase of accident. Copyright © 2017 Elsevier Ltd. All rights reserved.
Hybrid Wireless Hull Monitoring System for Naval Combat Vessels
2010-03-01
Payload Data Acquisition System (SPDAS) is designed by the Technology Management Group, Inc. ( TMG ). In its design, the monitoring system is intended...monitoring system custom designed by TMG for the U.S. Navy. The Scientific Payload Data Acquisition System (SPDAS) is a wired hull monitoring system
40 CFR 265.91 - Ground-water monitoring system.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 26 2011-07-01 2011-07-01 false Ground-water monitoring system. 265.91... DISPOSAL FACILITIES Ground-Water Monitoring § 265.91 Ground-water monitoring system. (a) A ground-water monitoring system must be capable of yielding ground-water samples for analysis and must consist of: (1...
33 CFR 157.12 - Oil discharge monitoring and control system.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Oil discharge monitoring and... CARRYING OIL IN BULK Design, Equipment, and Installation § 157.12 Oil discharge monitoring and control system. (a) Each vessel must have an oil discharge monitoring and control system (monitoring system) that...
33 CFR 157.12 - Oil discharge monitoring and control system.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Oil discharge monitoring and... CARRYING OIL IN BULK Design, Equipment, and Installation § 157.12 Oil discharge monitoring and control system. (a) Each vessel must have an oil discharge monitoring and control system (monitoring system) that...
33 CFR 157.12 - Oil discharge monitoring and control system.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Oil discharge monitoring and... CARRYING OIL IN BULK Design, Equipment, and Installation § 157.12 Oil discharge monitoring and control system. (a) Each vessel must have an oil discharge monitoring and control system (monitoring system) that...
33 CFR 157.12 - Oil discharge monitoring and control system.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Oil discharge monitoring and... CARRYING OIL IN BULK Design, Equipment, and Installation § 157.12 Oil discharge monitoring and control system. (a) Each vessel must have an oil discharge monitoring and control system (monitoring system) that...
33 CFR 157.12 - Oil discharge monitoring and control system.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Oil discharge monitoring and... CARRYING OIL IN BULK Design, Equipment, and Installation § 157.12 Oil discharge monitoring and control system. (a) Each vessel must have an oil discharge monitoring and control system (monitoring system) that...
40 CFR 258.51 - Ground-water monitoring systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 25 2014-07-01 2014-07-01 false Ground-water monitoring systems. 258... CRITERIA FOR MUNICIPAL SOLID WASTE LANDFILLS Ground-Water Monitoring and Corrective Action § 258.51 Ground-water monitoring systems. (a) A ground-water monitoring system must be installed that consists of a...
40 CFR 258.51 - Ground-water monitoring systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 26 2012-07-01 2011-07-01 true Ground-water monitoring systems. 258.51... FOR MUNICIPAL SOLID WASTE LANDFILLS Ground-Water Monitoring and Corrective Action § 258.51 Ground-water monitoring systems. (a) A ground-water monitoring system must be installed that consists of a...
40 CFR 265.91 - Ground-water monitoring system.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 27 2012-07-01 2012-07-01 false Ground-water monitoring system. 265.91... DISPOSAL FACILITIES Ground-Water Monitoring § 265.91 Ground-water monitoring system. (a) A ground-water monitoring system must be capable of yielding ground-water samples for analysis and must consist of: (1...
40 CFR 265.91 - Ground-water monitoring system.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 27 2013-07-01 2013-07-01 false Ground-water monitoring system. 265.91... DISPOSAL FACILITIES Ground-Water Monitoring § 265.91 Ground-water monitoring system. (a) A ground-water monitoring system must be capable of yielding ground-water samples for analysis and must consist of: (1...
40 CFR 257.22 - Ground-water monitoring systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 25 2014-07-01 2014-07-01 false Ground-water monitoring systems. 257... Waste Disposal Units Ground-Water Monitoring and Corrective Action § 257.22 Ground-water monitoring systems. (a) A ground-water monitoring system must be installed that consists of a sufficient number of...
40 CFR 265.91 - Ground-water monitoring system.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 26 2014-07-01 2014-07-01 false Ground-water monitoring system. 265.91... DISPOSAL FACILITIES Ground-Water Monitoring § 265.91 Ground-water monitoring system. (a) A ground-water monitoring system must be capable of yielding ground-water samples for analysis and must consist of: (1...
40 CFR 258.51 - Ground-water monitoring systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Ground-water monitoring systems. 258... CRITERIA FOR MUNICIPAL SOLID WASTE LANDFILLS Ground-Water Monitoring and Corrective Action § 258.51 Ground-water monitoring systems. (a) A ground-water monitoring system must be installed that consists of a...
40 CFR 257.22 - Ground-water monitoring systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Ground-water monitoring systems. 257... Waste Disposal Units Ground-Water Monitoring and Corrective Action § 257.22 Ground-water monitoring systems. (a) A ground-water monitoring system must be installed that consists of a sufficient number of...
40 CFR 60.1250 - What is my schedule for evaluating continuous emission monitoring systems?
Code of Federal Regulations, 2011 CFR
2011-07-01
... continuous emission monitoring systems? 60.1250 Section 60.1250 Protection of Environment ENVIRONMENTAL... Continuous Emission Monitoring § 60.1250 What is my schedule for evaluating continuous emission monitoring systems? (a) Conduct annual evaluations of your continuous emission monitoring systems no more than 13...
40 CFR 60.1235 - How are the data from the continuous emission monitoring systems used?
Code of Federal Regulations, 2010 CFR
2010-07-01
... emission monitoring systems used? 60.1235 Section 60.1235 Protection of Environment ENVIRONMENTAL... Continuous Emission Monitoring § 60.1235 How are the data from the continuous emission monitoring systems used? You must use data from the continuous emission monitoring systems for sulfur dioxide, nitrogen...
40 CFR 60.1235 - How are the data from the continuous emission monitoring systems used?
Code of Federal Regulations, 2011 CFR
2011-07-01
... emission monitoring systems used? 60.1235 Section 60.1235 Protection of Environment ENVIRONMENTAL... Continuous Emission Monitoring § 60.1235 How are the data from the continuous emission monitoring systems used? You must use data from the continuous emission monitoring systems for sulfur dioxide, nitrogen...
Code of Federal Regulations, 2011 CFR
2011-07-01
... meet for the operation of my continuous emission monitoring systems and continuous opacity monitoring system? 62.15220 Section 62.15220 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... the operation of my continuous emission monitoring systems and continuous opacity monitoring system...
Code of Federal Regulations, 2010 CFR
2010-07-01
... meet for the operation of my continuous emission monitoring systems and continuous opacity monitoring system? 62.15220 Section 62.15220 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... the operation of my continuous emission monitoring systems and continuous opacity monitoring system...
Wood, Curtis R; Chapman, Jason W; Reynolds, Donald R; Barlow, Janet F; Smith, Alan D; Woiwod, Ian P
2006-03-01
Insects migrating at high altitude over southern Britain have been continuously monitored by automatically operating, vertical-looking radars over a period of several years. During some occasions in the summer months, the migrants were observed to form well-defined layer concentrations, typically at heights of 200-400 m, in the stable night-time atmosphere. Under these conditions, insects are likely to have control over their vertical movements and are selecting flight heights that are favourable for long-range migration. We therefore investigated the factors influencing the formation of these insect layers by comparing radar measurements of the vertical distribution of insect density with meteorological profiles generated by the UK Meteorological Office's (UKMO) Unified Model (UM). Radar-derived measurements of mass and displacement speed, along with data from Rothamsted Insect Survey light traps, provided information on the identity of the migrants. We present here three case studies where noctuid and pyralid moths contributed substantially to the observed layers. The major meteorological factors influencing the layer concentrations appeared to be: (a) the altitude of the warmest air, (b) heights corresponding to temperature preferences or thresholds for sustained migration and (c) on nights when air temperatures are relatively high, wind-speed maxima associated with the nocturnal jet. Back-trajectories indicated that layer duration may have been determined by the distance to the coast. Overall, the unique combination of meteorological data from the UM and insect data from entomological radar described here show considerable promise for systematic studies of high-altitude insect layering.
A remote drip infusion monitoring system employing Bluetooth.
Amano, Hikaru; Ogawa, Hidekuni; Maki, Hiromichi; Tsukamoto, Sosuke; Yonezawa, Yoshiharu; Caldwell, W Morton
2012-01-01
We have developed a remote drip infusion monitoring system for use in hospitals. The system consists of several infusion monitoring devices and a central monitor. The infusion monitoring device employing a Bluetooth module can detect the drip infusion rate and an empty infusion solution bag, and then these data are sent to the central monitor placed at the nurses' station via the Bluetooth. The central monitor receives the data from several infusion monitoring devices and then displays graphically them. Therefore, the developed system can monitor intensively the drip infusion situation of the several patients at the nurses' station.
The future of remote ECG monitoring systems.
Guo, Shu-Li; Han, Li-Na; Liu, Hong-Wei; Si, Quan-Jin; Kong, De-Feng; Guo, Fu-Su
2016-09-01
Remote ECG monitoring systems are becoming commonplace medical devices for remote heart monitoring. In recent years, remote ECG monitoring systems have been applied in the monitoring of various kinds of heart diseases, and the quality of the transmission and reception of the ECG signals during remote process kept advancing. However, there remains accompanying challenges. This report focuses on the three components of the remote ECG monitoring system: patient (the end user), the doctor workstation, and the remote server, reviewing and evaluating the imminent challenges on the wearable systems, packet loss in remote transmission, portable ECG monitoring system, patient ECG data collection system, and ECG signals transmission including real-time processing ST segment, R wave, RR interval and QRS wave, etc. This paper tries to clarify the future developmental strategies of the ECG remote monitoring, which can be helpful in guiding the research and development of remote ECG monitoring.
Code of Federal Regulations, 2011 CFR
2011-07-01
... opacity monitoring system and how are the data used? 60.1270 Section 60.1270 Protection of Environment... Continuous Emission Monitoring § 60.1270 What is required for my continuous opacity monitoring system and how... system. (b) Install, evaluate, and operate each continuous opacity monitoring system according to § 60.13...
Szabo, Z.; Oden, J.H.; Gibs, J.; Rice, D.E.; Ding, Y.; ,
2001-01-01
Particulates that move with ground water and those that are artificially mobilized during well purging could be incorporated into water samples during collection and could cause trace-element concentrations to vary in unfiltered samples, and possibly in filtered samples (typically 0.45-um (micron) pore size) as well, depending on the particle-size fractions present. Therefore, measured concentrations may not be representative of those in the aquifer. Ground water may contain particles of various sizes and shapes that are broadly classified as colloids, which do not settle from water, and particulates, which do. In order to investigate variations in trace-element concentrations in ground-water samples as a function of particle concentrations and particle-size fractions, the U.S. Geological Survey, in cooperation with the U.S. Air Force, collected samples from five wells completed in the unconfined, oxic Kirkwood-Cohansey aquifer system of the New Jersey Coastal Plain. Samples were collected by purging with a portable pump at low flow (0.2-0.5 liters per minute and minimal drawdown, ideally less than 0.5 foot). Unfiltered samples were collected in the following sequence: (1) within the first few minutes of pumping, (2) after initial turbidity declined and about one to two casing volumes of water had been purged, and (3) after turbidity values had stabilized at less than 1 to 5 Nephelometric Turbidity Units. Filtered samples were split concurrently through (1) a 0.45-um pore size capsule filter, (2) a 0.45-um pore size capsule filter and a 0.0029-um pore size tangential-flow filter in sequence, and (3), in selected cases, a 0.45-um and a 0.05-um pore size capsule filter in sequence. Filtered samples were collected concurrently with the unfiltered sample that was collected when turbidity values stabilized. Quality-assurance samples consisted of sequential duplicates (about 25 percent) and equipment blanks. Concentrations of particles were determined by light scattering. Variations in concentrations aluminum and iron (1 -74 and 1-199 ug/L (micrograms per liter), respectively), common indicators of the presence of particulate-borne trace elements, were greatest in sample sets from individual wells with the greatest variations in turbidity and particle concentration. Differences in trace-element concentrations in sequentially collected unfiltered samples with variable turbidity were 5 to 10 times as great as those in concurrently collected samples that were passed through various filters. These results indicate that turbidity must be both reduced and stabilized even when low-flow sample-collection techniques are used in order to obtain water samples that do not contain considerable particulate artifacts. Currently (2001) available techniques need to be refined to ensure that the measured trace-element concentrations are representative of those that are mobile in the aquifer water.
Raízes pós-mitológicas da Astronomia Clássica
NASA Astrophysics Data System (ADS)
di Bartolo, L.; Villas da Rocha, J. F.
2004-02-01
Apresentamos como a invenção de um modelo astronômico e cosmológico fundado em causas naturais foi um processo gestado num ambiente cultural específico, o do advento do pensamento pós-mitológico, que tem como sua raiz mais funda a trajetória particular da Grécia Antiga, com ênfase na resolução de uma grave crise social e a evolução do mundo clássico para o contexto espiritual de um império universal.
Dehydration and clearing of adult Drosophila for ultramicroscopy.
Becker, Klaus; Jährling, Nina; Saghafi, Saiedeh; Dodt, Hans-Ulrich
2013-07-01
This protocol describes the preparation of adult flies for ultramicroscopy (UM), a powerful imaging technique that achieves precise and accurate three-dimensional (3D) reconstructions of intact macroscopic specimens with micrometer resolution. In UM, a specimen in the size range of ∼1-15 mm is illuminated perpendicular to the observation pathway by two thin counterpropagating sheets of laser light. Thus, specimens for UM need to be sufficiently transparent, which requires chemical clearing in most cases. In this protocol, Drosophila melanogaster adults are fixed, dehydrated in ethanol, and then cleared in a solution of benzyl alcohol and benzyl benzoate.
VizieR Online Data Catalog: GJ 1214b optical and near-IR transit phot. (Angerhausen+, 2017)
NASA Astrophysics Data System (ADS)
Angerhausen, D.; Dreyer, C.; Placek, B.; Csizmadia, Sz.; Eigmueller, P.; Godolt, M.; Kitzmann, D.; Mallonn, M.; Becklin, E.; Collins, P.; Dunham, E. W.; Grenfell, J. L.; Hamilton, R. T.; Kabath, P.; Logsdon, S. E.; Mandell, A.; Mandushev, G.; McElwain, M.; McLean, I. S.; Pfueller, E.; Rauer, H.; Savage, M.; Shenoy, S.; Vacca, W. D.; van Cleve, J. E.; Wiedemann, M.; Wolf, J.
2017-11-01
The joint US-German Cycle 2 Guest Investigator (GI) programme - US-proposal: Angerhausen (2013); Germanproposal: Dreyer (2013) - was performed on SOFIAs flight number 149 on UT February 27, 2014. Observations were simultaneously conducted in two optical HIPO channels: open blue at 0.3-0.6um and Sloan z' at 0.9-m; and one infrared FLITECAM fiter: Paschen-α cont. at 1.9um. Complementary data were also obtained with the optical focal plane guiding camera FPI+ in the Sloan i' band (0.8um). (5 data files).
Landsat 7 - First Cloud-free Image of Yellowstone National Park
NASA Technical Reports Server (NTRS)
2002-01-01
This image of Yellowstone Lake, in the center of Yellowstone National Park, was taken by Landsat 7 on July 13, 1999. Bands 5 (1.65um),4 (.825um), and 2 (.565um) were used for red, green, and blue, respectively. Water appears blue/black, snow light blue, mature forest red/green, young forest pink, and grass and fields appear light green. Southwest of the lake is young forest that is growing in the wake of the widespread fires of 1988. For more information, see: Landsat 7 Fact Sheet Landsat 7 in Mission Control Image by Rich Irish, NASA GSFC
VizieR Online Data Catalog: ISOCAM survey of Serpens/G3-G6 (Djupvik+, 2006)
NASA Astrophysics Data System (ADS)
Djupvik, A. A.; Andre, P.; Bontemps, S.; Motte, F.; Olofsson, G.; Gaalfalk, M.; Floren, H.-G.
2006-08-01
We present results from an ISOCAM survey in the two broadband filters LW2 (5-8.5um) and LW3 (12-18um) of a 19'x16' field called Serp_NH3 centred on the optical group Serpens/G3-G6. A total of 186 sources were detected in the 6.7um band and/or the 14.3um band to a limiting sensitivity of ~2mJy. These have been cross-correlated with the 2MASS catalogue and are all listed in table1. Deep follow-up photometry in the Ks band obtained with Arnica at the Nordic Optical Telescope (NOT) is listed in table2. Deep L' band photometry of selected sources using SIRCA at the NOT is listed in table3. Continuum emission at 1.3mm and 3.6cm was observed with IRAM and VLA, respectively, and deep imaging in the 2.12um S(1) line of H2 was obtained with NOTCam at the NOT. We find strong evidence for a stellar population of 31 Class II sources (listed in table5), 5 flat-spectrum sources, 5 Class I sources (listed in table4), and two Class 0 sources. Our method does not sample the Class III sources. (3 data files).
Ultramicroscopy as a novel tool to unravel the tropism of AAV gene therapy vectors in the brain.
Alves, Sandro; Bode, Julia; Bemelmans, Alexis-Pierre; von Kalle, Christof; Cartier, Nathalie; Tews, Björn
2016-06-20
Recombinant adeno-associated viral (AAV) vectors have advanced to the vanguard of gene therapy. Numerous naturally occurring serotypes have been used to target cells in various tissues. There is a strong need for fast and dynamic methods which efficiently unravel viral tropism in whole organs. Ultramicroscopy (UM) is a novel fluorescence microscopy technique that images optically cleared undissected specimens, achieving good resolutions at high penetration depths while being non-destructive. UM was applied to obtain high-resolution 3D analysis of AAV transduction in adult mouse brains, especially in the hippocampus, a region of interest for Alzheimer's disease therapy. We separately or simultaneously compared transduction efficacies for commonly used serotypes (AAV9 and AAVrh10) using fluorescent reporter expression. We provide a detailed comparative and quantitative analysis of the transduction profiles. UM allowed a rapid analysis of marker fluorescence expression in neurons with intact projections deep inside the brain, in defined anatomical structures. Major hippocampal neuronal transduction was observed with both vectors, with slightly better efficacy for AAV9 in UM. Glial response and synaptic marker expression did not change post transduction.We propose UM as a novel valuable complementary tool to efficiently and simultaneously unravel tropism of different viruses in a single non-dissected adult rodent brain.
Bailey, Fiona P; Clarke, Kim; Kalirai, Helen; Kenyani, Jenna; Shahidipour, Haleh; Falciani, Francesco; Coulson, Judy M; Sacco, Joseph J; Coupland, Sarah E; Eyers, Patrick A
2018-03-01
Metastatic uveal melanoma (UM) is invariably fatal, usually within a year of diagnosis. There are currently no effective therapies, and clinical studies employing kinase inhibitors have so far demonstrated limited success. This is despite common activating mutations in GNAQ/11 genes, which trigger signalling pathways that might predispose tumours to a variety of targeted drugs. In this study, we have profiled kinome expression network dynamics in various human ocular melanomas. We uncovered a shared transcriptional profile in human primary UM samples and across a variety of experimental cell-based models. The poor overall response of UM cells to FDA-approved kinase inhibitors contrasted with much higher sensitivity to the bromodomain inhibitor JQ1, a broad transcriptional repressor. Mechanistically, we identified a repressed FOXM1-dependent kinase subnetwork in JQ1-exposed cells that contained multiple cell cycle-regulated protein kinases. Consistently, we demonstrated vulnerability of UM cells to inhibitors of mitotic protein kinases within this network, including the investigational PLK1 inhibitor BI6727. We conclude that analysis of kinome-wide signalling network dynamics has the potential to reveal actionable drug targets and inhibitors of potential therapeutic benefit for UM patients. © 2017 The Authors. Pigment Cell & Melanoma Research Published by John Wiley & Sons.
VizieR Online Data Catalog: Water masers in M31. I. Recombination lines (Darling+, 2016)
NASA Astrophysics Data System (ADS)
Darling, J.; Gerard, B.; Amiri, N.; Lawrence, K.
2016-09-01
We constructed a catalog of 506 unresolved 24um sources from the Spitzer 24um map of M31 (Gordon et al. 2006ApJ...638L..87G); see Figure 1. Darling (2011ApJ...732L...2D) observed 206 24um sources in M31 using the Green Bank Telescope (GBT) in 2010 October through December. The 616-523 22.23508GHz ortho-water maser line observations were reported in Darling (2011ApJ...732L...2D), but simultaneous observations of the para-ammonia (NH3) rotational ground-state inversion transitions in the metastable states (J,K)=(1,1) and (2,2) at 23.6945 and 23.72263GHz, respectively, and the hydrogen recombination line H66α at 22.36417GHz were not. We subsequently observed all four of these lines toward an additional 300 24um sources in 2011 October through 2012 January. The resolution of the 24um Spitzer image is 6" (Gordon et al. 2006ApJ...638L..87G), so the unresolved IR sources remained within the 33" GBT beam even during the largest pointing drifts. The 33" beam (FWHM) at 22GHz spans 125pc in M31. (1 data file).
Bishop, Malcolm G. H.
2017-01-01
In 1978 M. J. Peterson examined the role played by the Royal College of Surgeons (RCS) in nineteenth-century dental reform, noting the establishment of its Licence in Dental Surgery (LDS) in 1859. In a paper published in Notes and Records in 2010, the present author described the influential role played by Fellows of the Royal Society during the nineteenth-century campaign for dental reform led by Sir John Tomes. Key players in this campaign, including the dentists Samuel Cartwright, Thomas Bell and James Salter, were, as well as being Fellows of the Royal Society, members of the Athenæum Club. The present research report indicates the roles played by those members of the Athenæum Club who were also Fellows of the Royal Society in the scientific and professional reform of nineteenth-century dentistry. Although it does not attempt to document meetings at the Club, it suggests the potential for a symbiotic effect between the Royal Society and the Athenæum. Where the previous paper proposed an active scientific role for the Royal Society in reforming dentistry, this paper presents the Athenæum as a significant extension of the sphere of influence into the cultural realm for those who did enjoy membership of both organizations.
Organic mixed conductors for bioelectronic applications (Conference Presentation)
NASA Astrophysics Data System (ADS)
Rivnay, Jonathan
2016-09-01
Direct measurement and stimulation of electrophysiological activity is a staple of neural and cardiac health monitoring, diagnosis and/or therapy. The ability to sensitively detect these signals can be enhanced by organic electronic materials that show mixed conduction properties (both electronic and ionic transport) in order to bridge the inherent mismatch that is prevalent between biological systems and traditional microelectronic materials/devices. Organic electrochemical transistors (OECTs) are one class of devices that utilize organic mixed conductors as the transistor channel, and have shown considerable promise as amplifying transducers due to their stability in aqueous conditions and high transconductance. These devices are fabricated in flexible, conformable form factors for in vivo recordings of epileptic activity, and for cutaneous EEG and ECG recordings in human subjects. The majority of high performance devices are based on conducting polymers such as poly(3,4-ethylenedioxythiophene) :poly(styrenesulfonate), PEDOT:PSS. By investigating PEDOT-based materials and devices, we are able to construct design rules for new formulations/materials. Introducing glycolated side chains to carefully selected semiconducting polymer backbones has enabled a new class high performance bioelectronic materials that feature high volumetric capacitance, transconductance >10mS (device dimensions ca. 10um), and steep subthreshold switching characteristics. A sub-set of these materials outperform PEDOT:PSS and shows significant promise for low power in vitro and in vivo biosensing applications.
Assessment of earthquake effects - contribution from online communication
NASA Astrophysics Data System (ADS)
D'Amico, Sebastiano; Agius, Matthew; Galea, Pauline
2014-05-01
The rapid increase of social media and online newspapers in the last years have given the opportunity to make a national investigation on macroseismic effects on the Maltese Islands based on felt earthquake reports. A magnitude 4.1 earthquake struck close to Malta on Sunday 24th April 2011 at 13:02 GMT. The earthquake was preceded and followed by a series of smaller magnitude quakes throughout the day, most of which were felt by the locals on the island. The continuous news media coverage during the day and the extensive sharing of the news item on social media resulted in a strong public response to fill in the 'Did you feel it?' online form on the website of the Seismic Monitoring and Research Unit (SMRU) at the University of Malta (http://seismic.research.um.edu.mt/). The results yield interesting information about the demographics of the island, and the different felt experiences possibly relating to geological settings and diverse structural and age-classified buildings. Based on this case study, the SMRU is in the process of developing a mobile phone application dedicated to share earthquake information to the local community. The application will automatically prompt users to fill in a simplified 'Did you feel it?' report to potentially felt earthquakes. Automatic location using Global Positioning Systems can be incorporated to provide a 'real time' intensity map that can be used by the Civil Protection Department.
ERIC Educational Resources Information Center
Harris, Julian; Maurer, Hermann
An investigation into high level event monitoring within the scope of a well-known multimedia application, HyperCard--a program on the Macintosh computer, is carried out. A monitoring system is defined as a system which automatically monitors usage of some activity and gathers statistics based on what is has observed. Monitor systems can give the…
Code of Federal Regulations, 2011 CFR
2011-07-01
... meet for the operation of my continuous emission monitoring systems and continuous opacity monitoring system? 60.1765 Section 60.1765 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... continuous emission monitoring systems and continuous opacity monitoring system? Use the required span values...
Code of Federal Regulations, 2010 CFR
2010-07-01
... meet for the operation of my continuous emission monitoring systems and continuous opacity monitoring system? 60.1765 Section 60.1765 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... continuous emission monitoring systems and continuous opacity monitoring system? Use the required span values...
1977-01-01
ENGINEERING INC * 2 e GENERAL i:tT~ LU l4 e DEWEEY ELECI-ONICS CORP It 160 E GENERAL I % 5TkUM E’t: 61.mP 9 43 DIGITAL CCt.MUNICATIONS C3O* 49 8...NORTHROP CORP • 63 h RANE CORP -- , 424 N NORTHWESTERN UNIVERSITY 4 .27 E RAYCLPN INOUSTKIES INC 383 8 OCEAN DATA SYSTEMS INC • 481 8 RAYPhNO ENGINEERING ...CONTROL INC . 344 h VIRGLNIA UNIVEkSITY (.;F 268 a SYSTEMS ENGINE -ING LAdORATONIES * 366 e VISIDYNE INC 26? 8 SYSTEMS EXPLOQATICN INC * 62 e VOUGHT CORP
Poveda, Vanessa de Brito; Nascimento, Ariane de Souza
2016-01-01
To verify the correlation between temperature measurements performed using an infrared tympanic thermometer and an esophageal thermometer during the intraoperative period. A longitudinal study of repeated measures was performed including subjects aged 18 years or older undergoing elective oncologic surgery of the digestive system, with anesthesia duration of at least 1 hour. Temperature measurements were performed simultaneously by a calibrated esophageal thermometer and by a calibrated infrared tympanic thermometer, with laboratory reading precision of ±0.2ºC. The operating room temperature remained between 19 and 21ºC. The study included 51 patients, mostly men (51%), white (80.4%). All patients were kept warm by a forced-air heating system, for an average of 264.14 minutes (SD = 87.7). The two temperature measurements showed no different behavior over time (p = 0.2205), however, tympanic measurements were consistently 1.24°C lower (p<0.0001). The tympanic thermometer presented reliable results but reflected lower temperatures than the esophageal thermometer. Verificar a correlação entre as medidas de temperatura realizadas por meio de um termômetro timpânico por infravermelho e por um termômetro esofágico, durante o período intraoperatório. Realizou-se um estudo longitudinal, de medidas repetidas, incluindo sujeitos com idade igual ou superior a 18 anos, submetidos à cirurgia oncológica eletiva do sistema digestório, com duração da anestesia de, no mínimo, 1 hora. As medidas de temperatura eram realizadas, ao mesmo tempo, por meio de um termômetro esofágico calibrado e por termômetro timpânico por infravermelho calibrado, com precisão de leitura em laboratório de ±0,2ºC. A temperatura da sala operatória permaneceu entre 19 e 21ºC. Foram incluídos 51 pacientes, em sua maioria homens (51%), brancos (80,4%). Todos os pacientes foram aquecidos com o sistema de ar forçado aquecido, em média por 264,14 minutos (DP = 87,7). As duas medidas de temperatura não tiveram comportamento diferente ao longo do tempo (p = 0,2205), mas a medida timpânica foi consistentemente menor em 1,24°C (p < 0,0001). O termômetro timpânico apresentou resultados confiáveis, mas refletiu temperaturas mais baixas do que o termômetro esofágico.
NASA Astrophysics Data System (ADS)
Bizheva, Kostadinka; Tan, Bingyao; Mason, Erik; Carter, Kirsten; Haines, Lacey; Sorbara, Luigina
2017-02-01
Keratoconus causes progressive morphological changes in the corneal epithelium (EPI), Bowman's membrane (BM) and anterior stroma. However, it is still not well understood if KC originates in the corneal epithelium and propagates to the anterior stroma through disruptions of the BM, or vice versa. In this study we used a sub-micrometer axial resolution OCT system to image in-vivo the cellular structure of the EPI layer and the fibrous structure of the BM and the anterior stroma in mild to advanced keratoconics, as well as healthy subjects. The imaging study was approved by the University of Waterloo Human Research Ethics Committee. The OCT system operates in the 800 nm spectral region at 34 kHz image acquisition rate and provides 0.95 um axial and < 2 um lateral resolution in corneal tissue, which is sufficient to visualize the cellular structure of the corneal epithelium and the fibrous structure of the BM. In some subjects, localized thinning and thickening of the EPI layer was observed, while there was no visible damage to the BM or anterior stroma. In other subjects, localized breakage of the stromal collagen fibrils was observed with no significant morphological changes of the corneal EPI.
Direct Generation and Detection of Quantum Correlated Photons with 3.2 um Wavelength Spacing.
Sua, Yong Meng; Fan, Heng; Shahverdi, Amin; Chen, Jia-Yang; Huang, Yu-Ping
2017-12-13
Quantum correlated, highly non-degenerate photons can be used to synthesize disparate quantum nodes and link quantum processing over incompatible wavelengths, thereby constructing heterogeneous quantum systems for otherwise unattainable superior performance. Existing techniques for correlated photons have been concentrated in the visible and near-IR domains, with the photon pairs residing within one micron. Here, we demonstrate direct generation and detection of high-purity photon pairs at room temperature with 3.2 um wavelength spacing, one at 780 nm to match the rubidium D2 line, and the other at 3950 nm that falls in a transparent, low-scattering optical window for free space applications. The pairs are created via spontaneous parametric downconversion in a lithium niobate waveguide with specially designed geometry and periodic poling. The 780 nm photons are measured with a silicon avalanche photodiode, and the 3950 nm photons are measured with an upconversion photon detector using a similar waveguide, which attains 34% internal conversion efficiency. Quantum correlation measurement yields a high coincidence-to-accidental ratio of 54, which indicates the strong correlation with the extremely non-degenerate photon pairs. Our system bridges existing quantum technology to the challenging mid-IR regime, where unprecedented applications are expected in quantum metrology and sensing, quantum communications, medical diagnostics, and so on.
Development of living body information monitoring system
NASA Astrophysics Data System (ADS)
Sakamoto, Hidetoshi; Ohbuchi, Yoshifumi; Torigoe, Ippei; Miyagawa, Hidekazu; Murayama, Nobuki; Hayashida, Yuki; Igasaki, Tomohiko
2010-03-01
The easy monitoring systems of contact and non-contact living body information for preventing the the Sudden Infant Death Syndrome (SIDS) were proposed as an alternative monitoring system of the infant's vital information. As for the contact monitoring system, respiration sensor, ECG electrodes, thermistor and IC signal processor were integrated into babies' nappy holder. This contact-monitoring unit has RF transmission function and the obtained data are analyzed in real time by PC. In non-contact mortaring system, the infrared thermo camera was used. The surrounding of the infant's mouth and nose is monitored and the respiration rate is obtained by thermal image processing of its temperature change image of expired air. This proposed system of in-sleep infant's vital information monitoring system and unit are very effective as not only infant's condition monitoring but also nursing person's one.
Development of living body information monitoring system
NASA Astrophysics Data System (ADS)
Sakamoto, Hidetoshi; Ohbuchi, Yoshifumi; Torigoe, Ippei; Miyagawa, Hidekazu; Murayama, Nobuki; Hayashida, Yuki; Igasaki, Tomohiko
2009-12-01
The easy monitoring systems of contact and non-contact living body information for preventing the the Sudden Infant Death Syndrome (SIDS) were proposed as an alternative monitoring system of the infant's vital information. As for the contact monitoring system, respiration sensor, ECG electrodes, thermistor and IC signal processor were integrated into babies' nappy holder. This contact-monitoring unit has RF transmission function and the obtained data are analyzed in real time by PC. In non-contact mortaring system, the infrared thermo camera was used. The surrounding of the infant's mouth and nose is monitored and the respiration rate is obtained by thermal image processing of its temperature change image of expired air. This proposed system of in-sleep infant's vital information monitoring system and unit are very effective as not only infant's condition monitoring but also nursing person's one.
30 CFR 77.312 - Fail safe monitoring systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Fail safe monitoring systems. 77.312 Section 77... Thermal Dryers § 77.312 Fail safe monitoring systems. Thermal dryer systems and controls shall be protected by a fail safe monitoring system which will safely shut down the system and any related equipment...
30 CFR 77.312 - Fail safe monitoring systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Fail safe monitoring systems. 77.312 Section 77... Thermal Dryers § 77.312 Fail safe monitoring systems. Thermal dryer systems and controls shall be protected by a fail safe monitoring system which will safely shut down the system and any related equipment...
30 CFR 77.312 - Fail safe monitoring systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Fail safe monitoring systems. 77.312 Section 77... Thermal Dryers § 77.312 Fail safe monitoring systems. Thermal dryer systems and controls shall be protected by a fail safe monitoring system which will safely shut down the system and any related equipment...
30 CFR 77.312 - Fail safe monitoring systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fail safe monitoring systems. 77.312 Section 77... Thermal Dryers § 77.312 Fail safe monitoring systems. Thermal dryer systems and controls shall be protected by a fail safe monitoring system which will safely shut down the system and any related equipment...
30 CFR 77.312 - Fail safe monitoring systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Fail safe monitoring systems. 77.312 Section 77... Thermal Dryers § 77.312 Fail safe monitoring systems. Thermal dryer systems and controls shall be protected by a fail safe monitoring system which will safely shut down the system and any related equipment...
Integrated photovoltaic (PV) monitoring system
NASA Astrophysics Data System (ADS)
Mahinder Singh, Balbir Singh; Husain, NurSyahidah; Mohamed, Norani Muti
2012-09-01
The main aim of this research work is to design an accurate and reliable monitoring system to be integrated with solar electricity generating system. The performance monitoring system is required to ensure that the PVEGS is operating at an optimum level. The PV monitoring system is able to measure all the important parameters that determine an optimum performance. The measured values are recorded continuously, as the data acquisition system is connected to a computer, and data is stored at fixed intervals. The data can be locally used and can also be transmitted via internet. The data that appears directly on the local monitoring system is displayed via graphical user interface that was created by using Visual basic and Apache software was used for data transmission The accuracy and reliability of the developed monitoring system was tested against the data that captured simultaneously by using a standard power quality analyzer device. The high correlation which is 97% values indicates the level of accuracy of the monitoring system. The aim of leveraging on a system for continuous monitoring system is achieved, both locally, and can be viewed simultaneously at a remote system.
40 CFR 75.10 - General operating requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... continuous emission monitoring system and a flow monitoring system with an automated data acquisition and handling system for measuring and recording SO2 concentration (in ppm), volumetric gas flow (in scfh), and... emission monitoring system and a flow monitoring system with an automated data acquisition and handling...
21 CFR 884.2800 - Computerized Labor Monitoring System.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Computerized Labor Monitoring System. 884.2800... Devices § 884.2800 Computerized Labor Monitoring System. (a) Identification. A computerized labor monitoring system is a system intended to continuously measure cervical dilation and fetal head descent and...
The U. S. Geological Survey, Digital Spectral Library: Version 1 (0.2 to 3.0um)
Clark, Roger N.; Swayze, Gregg A.; Gallagher, Andrea J.; King, Trude V.V.; Calvin, Wendy M.
1993-01-01
We have developed a digital reflectance spectral library, with management and spectral analysis software. The library includes 498 spectra of 444 samples (some samples include a series of grain sizes) measured from approximately 0.2 to 3.0 um . The spectral resolution (Full Width Half Maximum) of the reflectance data is <= 4 nm in the visible (0.2-0.8 um) and <= 10 nm in the NIR (0.8-2.35 um). All spectra were corrected to absolute reflectance using an NIST Halon standard. Library management software lets users search on parameters (e.g. chemical formulae, chemical analyses, purity of samples, mineral groups, etc.) as well as spectral features. Minerals from borate, carbonate, chloride, element, halide, hydroxide, nitrate, oxide, phosphate, sulfate, sulfide, sulfosalt, and the silicate (cyclosilicate, inosilicate, nesosilicate, phyllosilicate, sorosilicate, and tectosilicate) classes are represented. X-Ray and chemical analyses are tabulated for many of the entries, and all samples have been evaluated for spectral purity. The library also contains end and intermediate members for the olivine, garnet, scapolite, montmorillonite, muscovite, jarosite, and alunite solid-solution series. We have included representative spectra of H2O ice, kerogen, ammonium-bearing minerals, rare-earth oxides, desert varnish coatings, kaolinite crystallinity series, kaolinite-smectite series, zeolite series, and an extensive evaporite series. Because of the importance of vegetation to climate-change studies we have include 17 spectra of tree leaves, bushes, and grasses. The library and software are available as a series of U.S.G.S. Open File reports. PC user software is available to convert the binary data to ascii files (a separate U.S.G.S. open file report). Additionally, a binary data files are on line at the U.S.G.S. in Denver for anonymous ftp to users on the Internet. The library search software enables a user to search on documentation parameters as well as spectral features. The analysis system includes general spectral analysis routines, plotting packages, radiative transfer software for computing intimate mixtures, routines to derive optical constants from reflectance spectra, tools to analyze spectral features, and the capability to access imaging spectrometer data cubes for spectral analysis. Users may build customized libraries (at specific wavelengths and spectral resolution) for their own instruments using the library software. We are currently extending spectral coverage to 150 um. The libraries (original and convolved) will be made available in the future on a CD-ROM.
543 N McClurg, October 2010, Lindsay Light Radiological Survey
The field gamma measurements within the excavation andthe spoil materials generated during the excavation process did not exceed the respective thresholdvalues previously stated and ranged from a minim um of 1,020 cpm to a maxim um of 7,150 cpm.
VizieR Online Data Catalog: FourStar galaxy evolution survey (ZFOURGE) (Straatman+, 2016)
NASA Astrophysics Data System (ADS)
Straatman, C. M. S.; Spitler, L. R.; Quadri, R. F.; Labbe, I.; Glazebrook, K.; Persson, S. E.; Papovich, C.; Tran, K.-V.; Brammer, G. B.; Cowley, M.; Tomczak, A.; Nanayakkara, T.; Alcorn, L.; Allen, R.; Broussard, A.; van Dokkum, P.; Forrest, B.; van Houdt, J.; Kacprzak, G. G.; Kawinwanichakij, L.; Kelson, D. D.; Lee, J.; McCarthy, P. J.; Mehrtens, N.; Monson, A.; Murphy, D.; Rees, G.; Tilvi, V.; Whitaker, K. E.
2017-03-01
We present the FourStar galaxy evolution survey (ZFOURGE) photometric catalogs comprising >70000 galaxies, selected from ultradeep Ks-band detection images (25.5-26.5 AB mag, 5σ, total). We use 5 near-IR medium-bandwidth filters (J1, J2, J3, Hs, Hl) as well as broad-band Ks at 1.05-2.16 micron to 25-26 AB at a seeing of ~0.5 arcsec. Each field has ancillary imaging in 26-40 filters at 0.3-8 micron. We derive photometric redshifts, rest-frame U-V and V-J colors, and stellar population properties from SED fitting. The photometric redshifts have uncertainty σz=0.010, 0.009, and 0.011 in CDFS, COSMOS and UDS, respectively, if compared with spectroscopic redshifts. A pair test indicates σz,pairs=0.01-0.02 at 1
Parylene supported 20um*20um uncooled thermoelectric infrared detector with high fill factor
NASA Astrophysics Data System (ADS)
Modarres-Zadeh, Mohammad J.; Carpenter, Zachary S.; Rockley, Mark G.; Abdolvand, Reza
2012-06-01
Presented is a novel design for an uncooled surface-micromachined thermoelectric (TE) infrared (IR) detector. The detector features a P-doped polysilicon/Nichrome (Cr20-Ni80) thermocouple, which is embedded into a thin layer of Parylene-N to provide structural support. The low thermal conductivity (~0.1W/m.K), chemical resistance, and ease of deposition/patterning of Parylene-N make it an excellent choice of material for use in MEMS thermal detectors. This detector also features an umbrella-like IR absorber composed of a three layer stack of NiCr/SiN/NiCr to optimize IR absorption. The total device area is 20 um * 20 um per pixel with an absorber area of ~19 um * 19 um resulting in a fill factor of 90%. At room temperature, a DC responsivity of ~170V/W with a rise time of less than 8 ms is measured from the fabricated devices in vacuum when viewing a 500K blackbody without any concentrating optics. The dominant source of noise in thermoelectric IR detectors is typically Johnson noise when the detectors are operating in an open circuit condition. The fabricated detectors have resistances about 85KOhm which results in Johnson noise of about 38nV/Hz^0.5. The D* is calculated to be 9 * 106 cm*Hz0.5/ W. Preliminary finite element analysis indicates that the thermal conduction from the hot junction to the substrate through the TE wires is dominant ( GTE >> Gparylene) considering the fabricated dimensions of the parylene film and the TE wires. Thus, by further reducing the size of the TE wires, GTE can be decreased and hence, responsivity can be improved while the parylene film sustains the structural integrity of the cell.
Lynch, Caitlin; Pan, Yongmei; Li, Linhao; Heyward, Scott; Moeller, Timothy; Swaan, Peter W.; Wang, Hongbing
2014-01-01
Objective Accumulating evidence suggests that activation of mouse constitutive androstane receptor (mCAR) alleviates type 2 diabetes and obesity by inhibiting hepatic gluconeogenesis, lipogenesis, and fatty acid synthesis. However, the role of human (h) CAR in energy metabolism is largely unknown. The present study aims to investigate the effects of selective hCAR activators on hepatic energy metabolism in human primary hepatocytes (HPH). Methods Ligand-based structure-activity models were used for virtual screening of the Specs database (www.specs.net) followed by biological validation in cell-based luciferase assays. The effects of two novel hCAR activators (UM104 and UM145) on hepatic energy metabolism were evaluated in HPH. Results Real-time PCR and Western blotting analyses reveal that activation of hCAR by UM104 and UM145 significantly repressed the expression of glucose-6-phosphatase and phosphoenolpyruvate carboxykinase, two pivotal gluconeogenic enzymes, while exerting negligible effects on the expression of genes associated with lipogenesis and fatty acid synthesis. Functional experiments show that UM104 and UM145 markedly inhibit hepatic synthesis of glucose but not triglycerides in HPH. In contrast, activation of mCAR by 1,4-bis[2-(3,5-dichloropyridyloxy)]benzene, a selective mCAR activator, repressed the expression of genes associated with gluconeogenesis, lipogenesis, and fatty acid synthesis in mouse primary hepatocytes, which were consistent with previous observations in mouse model in vivo. Conclusion Our findings uncover an important species difference between hCAR and mCAR in hepatic energy metabolism, where hCAR selectively inhibits gluconeogenesis without suppressing fatty acid synthesis. Implications Such species selectivity should be considered when exploring CAR as a potential therapeutic target for metabolic disorders. PMID:24878338
Cheong, Kit-Leong; Wang, Lan-Ying; Wu, Ding-Tao; Hu, De-Jun; Zhao, Jing; Li, Shao-Ping
2016-09-01
Cordyceps sinensis is a well-known tonic food with broad medicinal properties. The aim of the present study was to investigate the optimization of microwave-assisted extraction (MAE) and characterize chemical structures and chain conformation of polysaccharides from a novel C. sinensis fungus UM01. Ion-exchange and gel filtration chromatography were used to purify the polysaccharides. The chemical structure of purified polysaccharide was determined through gas chromatography-mass spectrometry. Moreover, high performance size exclusion chromatography combined with refractive index detector and multiangle laser light scattering were conducted to analyze the molecular weight (Mw ) and chain conformation of purified polysaccharide. Based on the orthogonal design L9 , optimal MAE conditions could be obtained through 1300 W of microwave power, with a 5-min irradiation time at a solid to water ratio of 1:60, generating the highest extraction yield of 6.20%. Subsequently, the polysaccharide UM01-S1 was purified. The UM01-S1 is a glucan-type polysaccharide with a (1→4)-β-d-glucosyl backbone and branching points located at O-3 of Glcp with a terminal-d-Glcp. The Mw , radius of gyration (Rg ) and hydrodynamic radius (Rh ) of UM01-S1 were determined as 5.442 × 10(6) Da, 21.8 and 20.2 nm, respectively. Using the polymer solution theory, the exponent (ν) value of the power law function was calculated as 0.38, and the shape factor (ρ = Rg /Rh ) was 1.079, indicating that UM01-S1 has a sphere-like conformation with a branched structure in an aqueous solution. These results provide fundamental information for the future application of polysaccharides from cultured C. sinensis in health and functional food area. © 2016 Institute of Food Technologists®
Chromosomal rearrangements in uveal melanoma: Chromothripsis.
van Poppelen, Natasha M; Yavuzyigitoglu, Serdar; Smit, Kyra N; Vaarwater, Jolanda; Eussen, Bert; Brands, Tom; Paridaens, Dion; Kiliç, Emine; de Klein, Annelies
2018-05-04
Uveal melanoma (UM) is the most common primary intraocular malignancy in the Western world. Recurrent mutations in GNAQ, GNA11, CYSLTR2, PLCB4, BAP1, EIF1AX and SF3B1 are described as well as non-random chromosomal aberrations. Chromothripsis is a rare event in which chromosomes are shattered and rearranged and has been reported in a variety of cancers including UM. SNP arrays of 249 UM from patients who underwent enucleation, biopsy or endoresection were reviewed for the presence of chromothripsis. Chromothripsis was defined as ten or more breakpoints per chromosome involved. Genetic analysis of GNAQ, GNA11, BAP1, SF3B1 and EIF1AX was conducted using Sanger and next-generation sequencing. In addition, immunohistochemistry for BAP1 was performed. Chromothripsis was detected in seven out of 249 tumors and the affected chromosomes were chromosomes 3, 5, 6, 8, 12 and 13. The mean total of fragments per chromosome was 39.8 (range 12 - 116). In one UM, chromothripsis was present in two different chromosomes. GNAQ, GNA11 or CYSLTR2 mutations were present in six of these tumors and five tumors harbored a BAP1 mutation and/or lacked BAP1 protein expression by immunohistochemistry. Four of these tumors metastasized and for the fifth only short follow-up data are available. One of these metastatic tumors tumor harbored an SF3B1 mutation. No EIF1AX mutations were detected in any of the tumors. To conclude, chromothripsis is a rare event in UM, occurring in 2.8% of samples and without significant association with mutations in any of the common UM driver genes. This article is protected by copyright. All rights reserved. © 2018 Wiley Periodicals, Inc.
Ultramicronized palmitoylethanolamide (PEA-um(®)) in the treatment of idiopathic pulmonary fibrosis.
Di Paola, Rosanna; Impellizzeri, Daniela; Fusco, Roberta; Cordaro, Marika; Siracusa, Rosalba; Crupi, Rosalia; Esposito, Emanuela; Cuzzocrea, Salvatore
2016-09-01
Pulmonary fibrosis is a chronic condition characterized by progressive scarring of lung parenchyma. The aim of this study was to examine the effects of an ultramicronized preparation of palmitoylethanolamide (PEA-um(®)), an endogenous fatty acid amide, in mice subjected to idiopathic pulmonary fibrosis. Idiopathic pulmonary fibrosis was induced in male mice by a single intratracheal administration of saline with bleomycin sulphate (1mg/kg body weight) in a volume of 100μL. PEA-um(®) was injected intraperitoneally at 1, 3 or 10mg/kg 1h after bleomycin instillation and daily thereafter. Animals were sacrificed after 7 and 21days by pentobarbitone overdose. One cohort of mice was sacrificed after seven days of bleomycin administration, followed by bronchoalveloar lavage and determination of myeloperoxidase activity, lung edema and histopathology features. In the 21-day cohort, mortality was assessed daily, and surviving mice were sacrificed followed by the above analyses together with immunohistochemical localization of CD8, tumor necrosis factor-α, CD4, interleukin-1β, transforming growth factor-β, inducible nitric oxide synthase and basic fibroblast growth factor. Compared to bleomycin-treated mice, animals that received also PEA-um(®) (3 or 10mg/kg) had significantly decreased weight loss, mortality, inflammation, lung damage at the histological level, and lung fibrosis at 7 and 21days. PEA-um(®) (1mg/kg) did not significantly inhibit the inflammation response and lung fibrosis. This study demonstrates that PEA-um(®) (3 and 10mg/kg) reduces the extent of lung inflammation in a mouse model of idiopathic pulmonary fibrosis. Copyright © 2016 Elsevier Ltd. All rights reserved.
Targeting Bcl-2/Bcl-XL induces antitumor activity in uveal melanoma patient-derived xenografts.
Némati, Fariba; de Montrion, Catherine; Lang, Guillaume; Kraus-Berthier, Laurence; Carita, Guillaume; Sastre-Garau, Xavier; Berniard, Aurélie; Vallerand, David; Geneste, Olivier; de Plater, Ludmilla; Pierré, Alain; Lockhart, Brian; Desjardins, Laurence; Piperno-Neumann, Sophie; Depil, Stéphane; Decaudin, Didier
2014-01-01
Uveal melanoma (UM) is associated with a high risk of metastases and lack of efficient therapies. Reduced capacity for apoptosis induction by chemotherapies is one obstacle to efficient treatments. Human UM is characterized by high expression of the anti-apoptotic protein Bcl-2. Consequently, regulators of apoptosis such as Bcl-2 family inhibitors may constitute an attractive approach to UM therapeutics. In this aim, we have investigated the efficacy of the Bcl-2/Bcl-XL inhibitor S44563 on 4 UM Patient-Derived Xenografts (PDXs) and derived-cell lines. Four well characterized UM PDXs were used for in vivo experiments. S44563 was administered alone or combined with fotemustine either concomitantly or after the alkylating agent. Bcl-2, Bcl-XL, and Mcl-1 expressions after S44563 administration were evaluated by immunohistochemistry (IHC). S44563 administered alone by at 50 and 100 mg/kg i.p. induced a significant tumour growth inhibition in only one xenograft model with a clear dose effect. However, when S44563 was concomitantly administered with fotemustine, we observed a synergistic activity in 3 out of the 4 tested models. In addition, S44563 administered after fotemustine induced a tumour growth delay in 2 out of 3 tested xenografts. Finally, IHC analyses showed that Bcl-2, Bcl-XL, and Mcl-1 expression were not modified after S44563 administration. The novel anti-apoptotic experimental compound S44563, despite a relative low efficacy when administered alone, increased the efficacy of fotemustine in either concomitant or sequential combinations or indeed subsequent to fotemustine. These data support further exploration of potential therapeutic effect of Bcl-2/Bcl-xl inhibition in human UM.
Nor, Nor Azlida M; Yusof, Zamros Y M; Shahidan, Mohd Noor F M
2011-12-01
The Ministry of Higher Education in Malaysia has called for the implementation of a soft skills module in all public universities in Malaysia. In response to this and as part of curriculum development efforts for a new integrated program for 2011, a study was undertaken to improve the University of Malaya (UM) Faculty of Dentistry's communication skills course. One of the study objectives was to investigate dental students' attitudes towards communication skills learning and the association between their attitudes and demographic and education-related characteristics. A cross-sectional survey--using a self-administered twenty-four-item adapted Communication Skills Attitude Scale (CSAS) that contained both positive (PAS) and negative (NAS) attitude subscales--was carried out targeting all final-year dental students at the UM and the Universiti Kebangsaan Malaysia (UKM). A total of 148 students completed the survey, yielding a response rate of 88.1 percent. Overall, UKM students had significantly more positive attitudes towards communication skills learning (PAS score: mean=48.69, SD=4.48, p<0.001) than UM students (mean=46.03, SD=4.22). There was no statistically significant difference in negative attitudes between the two groups. UKM students with more positive attitudes tended to be female (p<0.05). UM students with more negative attitudes perceived themselves as poor communicators (p<0.05), and UKM students with more negative attitudes tended to have poor English proficiency (p<0.05). This study found that both UM and UKM final-year dental students have positive and negative attitudes towards learning communication skills. These attitudes were significantly associated with certain background and education-related attributes. Outcomes of this study served as a valuable guide in strengthening the communication skills course for the UM's new, integrated dental curriculum.
40 CFR 65.161 - Continuous records and monitoring system data handling.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Routing to a Fuel Gas System or a Process § 65.161 Continuous records and monitoring system data handling...) Monitoring system breakdowns, repairs, preventive maintenance, calibration checks, and zero (low-level) and... section unless an alternative monitoring or recordkeeping system has been requested and approved under...
40 CFR 65.161 - Continuous records and monitoring system data handling.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Routing to a Fuel Gas System or a Process § 65.161 Continuous records and monitoring system data handling...) Monitoring system breakdowns, repairs, preventive maintenance, calibration checks, and zero (low-level) and... section unless an alternative monitoring or recordkeeping system has been requested and approved under...
40 CFR 75.13 - Specific provisions for monitoring CO2 emissions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Specific provisions for monitoring CO2... monitoring CO2 emissions. (a) CO 2 continuous emission monitoring system. If the owner or operator chooses to... operating requirements in § 75.10 for a CO2 continuous emission monitoring system and flow monitoring system...
40 CFR 75.13 - Specific provisions for monitoring CO2 emissions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 16 2011-07-01 2011-07-01 false Specific provisions for monitoring CO2... monitoring CO2 emissions. (a) CO 2 continuous emission monitoring system. If the owner or operator chooses to... operating requirements in § 75.10 for a CO2 continuous emission monitoring system and flow monitoring system...
40 CFR 75.13 - Specific provisions for monitoring CO2 emissions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 17 2012-07-01 2012-07-01 false Specific provisions for monitoring CO2... monitoring CO2 emissions. (a) CO 2 continuous emission monitoring system. If the owner or operator chooses to... operating requirements in § 75.10 for a CO2 continuous emission monitoring system and flow monitoring system...
Use of Low-Cost Acquisition Systems with an Embedded Linux Device for Volcanic Monitoring
Moure, David; Torres, Pedro; Casas, Benito; Toma, Daniel; Blanco, María José; Del Río, Joaquín; Manuel, Antoni
2015-01-01
This paper describes the development of a low-cost multiparameter acquisition system for volcanic monitoring that is applicable to gravimetry and geodesy, as well as to the visual monitoring of volcanic activity. The acquisition system was developed using a System on a Chip (SoC) Broadcom BCM2835 Linux operating system (based on DebianTM) that allows for the construction of a complete monitoring system offering multiple possibilities for storage, data-processing, configuration, and the real-time monitoring of volcanic activity. This multiparametric acquisition system was developed with a software environment, as well as with different hardware modules designed for each parameter to be monitored. The device presented here has been used and validated under different scenarios for monitoring ocean tides, ground deformation, and gravity, as well as for monitoring with images the island of Tenerife and ground deformation on the island of El Hierro. PMID:26295394
Use of Low-Cost Acquisition Systems with an Embedded Linux Device for Volcanic Monitoring.
Moure, David; Torres, Pedro; Casas, Benito; Toma, Daniel; Blanco, María José; Del Río, Joaquín; Manuel, Antoni
2015-08-19
This paper describes the development of a low-cost multiparameter acquisition system for volcanic monitoring that is applicable to gravimetry and geodesy, as well as to the visual monitoring of volcanic activity. The acquisition system was developed using a System on a Chip (SoC) Broadcom BCM2835 Linux operating system (based on DebianTM) that allows for the construction of a complete monitoring system offering multiple possibilities for storage, data-processing, configuration, and the real-time monitoring of volcanic activity. This multiparametric acquisition system was developed with a software environment, as well as with different hardware modules designed for each parameter to be monitored. The device presented here has been used and validated under different scenarios for monitoring ocean tides, ground deformation, and gravity, as well as for monitoring with images the island of Tenerife and ground deformation on the island of El Hierro.
406 E Grand, October 2010, Lindsay Light Radiological Survey
The field gamma measurements within the excavation and the spoil materials generated during the excavation process did not exceed the respective threshold values previously stated and ranged from a minim um of 1, 120 cpm to a maxim um of 6,640 cpm.
VizieR Online Data Catalog: SCUBA-2 high-redshift galaxies sample (Barger+, 2014)
NASA Astrophysics Data System (ADS)
Barger, A. J.; Cowie, L. L.; Chen, C.-C.; Owen, F. N.; Wang, W.-H.; Casey, C. M.; Lee, N.; Sanders, D. B.; Williams, J. P.
2017-05-01
We obtained 25.4 hr of observations on the CDF-N with SCUBA-2 on the JCMT during observing runs in 2012 and 2013. The data were obtained using a mixture of scanning modes and under a variety of weather conditions. Using the CV Daisy scanning mode (detailed information about the SCUBA-2 scan patterns can be found in Holland et al. 2013MNRAS.430.2513H), we obtained a 2.2 hr observation in band 1 weather (225 GHz opacity<0.05) and a 16.5 hr observation in band 2 weather (225 GHz opacity ~0.05-0.08). We also obtained a 6.7 hr observation in band 2 weather using the pong-900 scanning mode. While SCUBA-2 observes at both 450 um and 850 um simultaneously, there are too few sources directly detected at 450 um in our data to be interesting. Thus, we only use the 850 um data in our subsequent analysis. (1 data file).
Phillips, J S; Hamm, C K; Pierce, J R; Kussman, M J
1999-12-01
The Department of Defense has embraced utilization management (UM) as an important tool to control and possibly decrease medical costs. Budgetary withholds have been taken by the Office of the Assistant Secretary of Defense (Health Affairs) to encourage the military services to implement UM programs. In response, Walter Reed Army Medical Center implemented a UM program along with other initiatives to effect changes in the delivery of inpatient care. This paper describes this UM program and other organizational initiatives, such as the introduction of new levels of care in an attempt to effect reductions in length of stay and unnecessary admissions. We demonstrate the use of a diversity of databases and analytical methods to quantify improved utilization and management of resources. The initiatives described significantly reduced hospital length of stay and inappropriate inpatient days. Without solid command and clinical leadership support and empowerment of the professional staffs, these significant changes and improvements could not have occurred.
Peterson, Kristina; Rogers, Bonnie M. E.; Brosseau, Lisa M.; Payne, Julianne; Cooney, Jennifer; Joe, Lauren; Novak, Debra
2017-01-01
This article compares hospital managers’ (HM), unit managers’ (UM), and health care workers’ (HCW) perceptions of respiratory protection safety climate in acute care hospitals. The article is based on survey responses from 215 HMs, 245 UMs, and 1,105 HCWs employed by 98 acute care hospitals in six states. Ten survey questions assessed five of the key dimensions of safety climate commonly identified in the literature: managerial commitment to safety, management feedback on safety procedures, coworkers’ safety norms, worker involvement, and worker safety training. Clinically and statistically significant differences were found across the three respondent types. HCWs had less positive perceptions of management commitment, worker involvement, and safety training aspects of safety climate than HMs and UMs. UMs had more positive perceptions of management’s supervision of HCWs’ respiratory protection practices. Implications for practice improvements indicate the need for frontline HCWs’ inclusion in efforts to reduce safety climate barriers and better support effective respiratory protection programs and daily health protection practices. PMID:27056750
Peterson, Kristina; Rogers, Bonnie M E; Brosseau, Lisa M; Payne, Julianne; Cooney, Jennifer; Joe, Lauren; Novak, Debra
2016-07-01
This article compares hospital managers' (HM), unit managers' (UM), and health care workers' (HCW) perceptions of respiratory protection safety climate in acute care hospitals. The article is based on survey responses from 215 HMs, 245 UMs, and 1,105 HCWs employed by 98 acute care hospitals in six states. Ten survey questions assessed five of the key dimensions of safety climate commonly identified in the literature: managerial commitment to safety, management feedback on safety procedures, coworkers' safety norms, worker involvement, and worker safety training. Clinically and statistically significant differences were found across the three respondent types. HCWs had less positive perceptions of management commitment, worker involvement, and safety training aspects of safety climate than HMs and UMs. UMs had more positive perceptions of management's supervision of HCWs' respiratory protection practices. Implications for practice improvements indicate the need for frontline HCWs' inclusion in efforts to reduce safety climate barriers and better support effective respiratory protection programs and daily health protection practices. © 2016 The Author(s).
Robust boosting via convex optimization
NASA Astrophysics Data System (ADS)
Rätsch, Gunnar
2001-12-01
In this work we consider statistical learning problems. A learning machine aims to extract information from a set of training examples such that it is able to predict the associated label on unseen examples. We consider the case where the resulting classification or regression rule is a combination of simple rules - also called base hypotheses. The so-called boosting algorithms iteratively find a weighted linear combination of base hypotheses that predict well on unseen data. We address the following issues: o The statistical learning theory framework for analyzing boosting methods. We study learning theoretic guarantees on the prediction performance on unseen examples. Recently, large margin classification techniques emerged as a practical result of the theory of generalization, in particular Boosting and Support Vector Machines. A large margin implies a good generalization performance. Hence, we analyze how large the margins in boosting are and find an improved algorithm that is able to generate the maximum margin solution. o How can boosting methods be related to mathematical optimization techniques? To analyze the properties of the resulting classification or regression rule, it is of high importance to understand whether and under which conditions boosting converges. We show that boosting can be used to solve large scale constrained optimization problems, whose solutions are well characterizable. To show this, we relate boosting methods to methods known from mathematical optimization, and derive convergence guarantees for a quite general family of boosting algorithms. o How to make Boosting noise robust? One of the problems of current boosting techniques is that they are sensitive to noise in the training sample. In order to make boosting robust, we transfer the soft margin idea from support vector learning to boosting. We develop theoretically motivated regularized algorithms that exhibit a high noise robustness. o How to adapt boosting to regression problems? Boosting methods are originally designed for classification problems. To extend the boosting idea to regression problems, we use the previous convergence results and relations to semi-infinite programming to design boosting-like algorithms for regression problems. We show that these leveraging algorithms have desirable theoretical and practical properties. o Can boosting techniques be useful in practice? The presented theoretical results are guided by simulation results either to illustrate properties of the proposed algorithms or to show that they work well in practice. We report on successful applications in a non-intrusive power monitoring system, chaotic time series analysis and a drug discovery process. --- Anmerkung: Der Autor ist Träger des von der Mathematisch-Naturwissenschaftlichen Fakultät der Universität Potsdam vergebenen Michelson-Preises für die beste Promotion des Jahres 2001/2002. In dieser Arbeit werden statistische Lernprobleme betrachtet. Lernmaschinen extrahieren Informationen aus einer gegebenen Menge von Trainingsmustern, so daß sie in der Lage sind, Eigenschaften von bisher ungesehenen Mustern - z.B. eine Klassenzugehörigkeit - vorherzusagen. Wir betrachten den Fall, bei dem die resultierende Klassifikations- oder Regressionsregel aus einfachen Regeln - den Basishypothesen - zusammengesetzt ist. Die sogenannten Boosting Algorithmen erzeugen iterativ eine gewichtete Summe von Basishypothesen, die gut auf ungesehenen Mustern vorhersagen. Die Arbeit behandelt folgende Sachverhalte: o Die zur Analyse von Boosting-Methoden geeignete Statistische Lerntheorie. Wir studieren lerntheoretische Garantien zur Abschätzung der Vorhersagequalität auf ungesehenen Mustern. Kürzlich haben sich sogenannte Klassifikationstechniken mit großem Margin als ein praktisches Ergebnis dieser Theorie herausgestellt - insbesondere Boosting und Support-Vektor-Maschinen. Ein großer Margin impliziert eine hohe Vorhersagequalität der Entscheidungsregel. Deshalb wird analysiert, wie groß der Margin bei Boosting ist und ein verbesserter Algorithmus vorgeschlagen, der effizient Regeln mit maximalem Margin erzeugt. o Was ist der Zusammenhang von Boosting und Techniken der konvexen Optimierung? Um die Eigenschaften der entstehenden Klassifikations- oder Regressionsregeln zu analysieren, ist es sehr wichtig zu verstehen, ob und unter welchen Bedingungen iterative Algorithmen wie Boosting konvergieren. Wir zeigen, daß solche Algorithmen benutzt werden koennen, um sehr große Optimierungsprobleme mit Nebenbedingungen zu lösen, deren Lösung sich gut charakterisieren laesst. Dazu werden Verbindungen zum Wissenschaftsgebiet der konvexen Optimierung aufgezeigt und ausgenutzt, um Konvergenzgarantien für eine große Familie von Boosting-ähnlichen Algorithmen zu geben. o Kann man Boosting robust gegenüber Meßfehlern und Ausreissern in den Daten machen? Ein Problem bisheriger Boosting-Methoden ist die relativ hohe Sensitivität gegenüber Messungenauigkeiten und Meßfehlern in der Trainingsdatenmenge. Um dieses Problem zu beheben, wird die sogenannte 'Soft-Margin' Idee, die beim Support-Vector Lernen schon benutzt wird, auf Boosting übertragen. Das führt zu theoretisch gut motivierten, regularisierten Algorithmen, die ein hohes Maß an Robustheit aufweisen. o Wie kann man die Anwendbarkeit von Boosting auf Regressionsprobleme erweitern? Boosting-Methoden wurden ursprünglich für Klassifikationsprobleme entwickelt. Um die Anwendbarkeit auf Regressionsprobleme zu erweitern, werden die vorherigen Konvergenzresultate benutzt und neue Boosting-ähnliche Algorithmen zur Regression entwickelt. Wir zeigen, daß diese Algorithmen gute theoretische und praktische Eigenschaften haben. o Ist Boosting praktisch anwendbar? Die dargestellten theoretischen Ergebnisse werden begleitet von Simulationsergebnissen, entweder, um bestimmte Eigenschaften von Algorithmen zu illustrieren, oder um zu zeigen, daß sie in der Praxis tatsächlich gut funktionieren und direkt einsetzbar sind. Die praktische Relevanz der entwickelten Methoden wird in der Analyse chaotischer Zeitreihen und durch industrielle Anwendungen wie ein Stromverbrauch-Überwachungssystem und bei der Entwicklung neuer Medikamente illustriert.
Systems safety monitoring using the National Full-Scale Aerodynamic Complex Bar Chart Monitor
NASA Technical Reports Server (NTRS)
Jung, Oscar
1990-01-01
Attention is given to the Bar Chart Monitor system designed for safety monitoring of all model and facility test-related articles in wind tunnels. The system's salient features and its integration into the data acquisition system are discussed.
40 CFR 75.40 - General demonstration requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... (CONTINUED) CONTINUOUS EMISSION MONITORING Alternative Monitoring Systems § 75.40 General demonstration... continuous emission monitoring system may apply to the Administrator for approval of an alternative monitoring system (or system component) to determine average hourly emission data for SO2, NOX, and/or...
Tran, Nam K; Godwin, Zachary R; Steele, Amanda N; Wolf, Steven E; Palmieri, Tina L
2016-09-01
The goal of this study was to retrospectively evaluate the clinical impact of an accurate autocorrecting blood glucose monitoring system in children with severe burns. Blood glucose monitoring system accuracy is essential for providing appropriate intensive insulin therapy and achieving tight glycemic control in critically ill patients. Unfortunately, few comparison studies have been performed to evaluate the clinical impact of accurate blood glucose monitoring system monitoring in the high-risk pediatric burn population. Retrospective analysis of an electronic health record system. Pediatric burn ICU at an academic medical center. Children (aged < 18 yr) with severe burns (≥ 20% total body surface area) receiving intensive insulin therapy guided by either a noncorrecting (blood glucose monitoring system-1) or an autocorrecting blood glucose monitoring system (blood glucose monitoring system-2). Patient demographics, insulin rates, and blood glucose monitoring system measurements were collected. The frequency of hypoglycemia and glycemic variability was compared between the two blood glucose monitoring system groups. A total of 122 patient charts from 2001 to 2014 were reviewed. Sixty-three patients received intensive insulin therapy using blood glucose monitoring system-1 and 59 via blood glucose monitoring system-2. Patient demographics were similar between the two groups. Mean insulin infusion rates (5.1 ± 3.8 U/hr; n = 535 paired measurements vs 2.4 ± 1.3 U/hr; n = 511 paired measurements; p < 0.001), glycemic variability, and frequency of hypoglycemic events (90 vs 12; p < 0.001) were significantly higher in blood glucose monitoring system-1-treated patients. Compared with laboratory measurements, blood glucose monitoring system-2 yielded the most accurate results (mean ± SD bias: -1.7 ± 6.9 mg/dL [-0.09 ± 0.4 mmol/L] vs 7.4 ± 13.5 mg/dL [0.4 ± 0.7 mmol/L]). Blood glucose monitoring system-2 patients achieve glycemic control more quickly (5.7 ± 4.3 vs 13.1 ± 6.9 hr; p< 0.001) and stayed within the target glycemic control range longer compared with blood glucose monitoring system-1 patients (85.2% ± 13.9% vs 57.9% ± 29.1%; p < 0.001). Accurate autocorrecting blood glucose monitoring system optimizes intensive insulin therapy, improves tight glycemic control, and reduces the risk of hypoglycemia and glycemic variability. The use of an autocorrecting blood glucose monitoring system for intensive insulin therapy may improve glycemic control in severely burned children.
The Orion Bullets: New GEMS MCAO images
NASA Astrophysics Data System (ADS)
Ginsburg, Adam; Bally, John; Youngblood, Allison
2013-07-01
The Orion A molecular cloud (OMC1) is the nearest site of massive star formation at a distance of 414 pc. The BN/KL region within it contains signs of a massive explosion triggered 500 years ago by decay of a non- hierarchical multiple system of massive stars. We present observations of the OMC1 core at high spatial resolution (<0.1") in narrow-band [Fe II] 1.64um and H2 S(1) 1-0 2.12um filters. The new data reveal compact (0.1" to 0.5") knots with unique excitation and chemical properties, unveiling new details about the three-dimensional structure of the explosion. Bright H2 emission from these compact, high proper-motion knots and compact [Fe II] features are consistent with scenario proposed by Bally et al. (2011) in which they are interpreted to be high density (n > 10^8 cm^{-3}) disk fragments launched from within a few AU of a massive star by a > three-body dynamical interaction that led to the ejection of the BN objects and the formation of a compact (separation < few AU) binary, most likely radio source I. The proper motions are as high as 400 km/s, hinting at the enormous energy unleashed in the explosion. The data also unveiled a population of obscured close binary systems. This new population will allow a comparison of embedded young binary systems with the older, un-obscured, visual binary population to test models of the evolution of multiplicity statistics in the Orion Nebula Cluster.
40 CFR 75.24 - Out-of-control periods and adjustment for system bias.
Code of Federal Regulations, 2013 CFR
2013-07-01
... § 75.24 Out-of-control periods and adjustment for system bias. (a) If an out-of-control period occurs... monitor or continuous emission monitoring system is out-of-control, any data recorded by the monitor or... pursuant to § 75.32 of this part. (c) When a monitor or continuous emission monitoring system is out-of...
Coma Patient Monitoring System Using Image Processing
NASA Astrophysics Data System (ADS)
Sankalp, Meenu
2011-12-01
COMA PATIENT MONITORING SYSTEM provides high quality healthcare services in the near future. To provide more convenient and comprehensive medical monitoring in big hospitals since it is tough job for medical personnel to monitor each patient for 24 hours.. The latest development in patient monitoring system can be used in Intensive Care Unit (ICU), Critical Care Unit (CCU), and Emergency Rooms of hospital. During treatment, the patient monitor is continuously monitoring the coma patient to transmit the important information. Also in the emergency cases, doctor are able to monitor patient condition efficiently to reduce time consumption, thus it provides more effective healthcare system. So due to importance of patient monitoring system, the continuous monitoring of the coma patient can be simplified. This paper investigates about the effects seen in the patient using "Coma Patient Monitoring System" which is a very advanced product related to physical changes in body movement of the patient and gives Warning in form of alarm and display on the LCD in less than one second time. It also passes a sms to a person sitting at the distant place if there exists any movement in any body part of the patient. The model for the system uses Keil software for the software implementation of the developed system.
NASA Astrophysics Data System (ADS)
Andriushin, A. V.; Dolbikova, N. S.; Kiet, S. V.; Merzlikina, E. I.; Nikitina, I. S.
2017-11-01
The reliability of the main equipment of any power station depends on the correct water chemistry. In order to provide it, it is necessary to monitor the heat carrier quality, which, in its turn, is provided by the chemical monitoring system. Thus, the monitoring system reliability plays an important part in providing reliability of the main equipment. The monitoring system reliability is determined by the reliability and structure of its hardware and software consisting of sensors, controllers, HMI and so on [1,2]. Workers of a power plant dealing with the measuring equipment must be informed promptly about any breakdowns in the monitoring system, in this case they are able to remove the fault quickly. A computer consultant system for personnel maintaining the sensors and other chemical monitoring equipment can help to notice faults quickly and identify their possible causes. Some technical solutions for such a system are considered in the present paper. The experimental results were obtained on the laboratory and experimental workbench representing a physical model of a part of the chemical monitoring system.
Physiologic monitoring. A guide to networking your monitoring systems.
2011-10-01
There are many factors to consider when choosing a physiologic monitoring system. not only should these systems perform well clinically, but they should also be able to exchange data with other information systems. We discuss some of the ins and outs of physiologic monitoring system networking and highlight eight product lines from seven suppliers.
Shared performance monitor in a multiprocessor system
Chiu, George; Gara, Alan G; Salapura, Valentina
2014-12-02
A performance monitoring unit (PMU) and method for monitoring performance of events occurring in a multiprocessor system. The multiprocessor system comprises a plurality of processor devices units, each processor device for generating signals representing occurrences of events in the processor device, and, a single shared counter resource for performance monitoring. The performance monitor unit is shared by all processor cores in the multiprocessor system. The PMU is further programmed to monitor event signals issued from non-processor devices.
21 CFR 884.2800 - Computerized Labor Monitoring System.
Code of Federal Regulations, 2014 CFR
2014-04-01
... monitoring system is a system intended to continuously measure cervical dilation and fetal head descent and... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Computerized Labor Monitoring System. 884.2800... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Monitoring...
21 CFR 884.2800 - Computerized Labor Monitoring System.
Code of Federal Regulations, 2012 CFR
2012-04-01
... monitoring system is a system intended to continuously measure cervical dilation and fetal head descent and... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Computerized Labor Monitoring System. 884.2800... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Monitoring...
21 CFR 884.2800 - Computerized Labor Monitoring System.
Code of Federal Regulations, 2013 CFR
2013-04-01
... monitoring system is a system intended to continuously measure cervical dilation and fetal head descent and... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Computerized Labor Monitoring System. 884.2800... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Monitoring...
Promulgated quality assurance Procedure 5 Quality Assurance Requirements For Vapor Phase Mercury Continuous Emissions Monitoring Systems And Sorbent Trap Monitoring Systems Used For Compliance Determination At Stationary Sources
40 CFR 60.2941 - What is my schedule for evaluating continuous emission monitoring systems?
Code of Federal Regulations, 2010 CFR
2010-07-01
... continuous emission monitoring systems? 60.2941 Section 60.2941 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES... emission monitoring systems? (a) Conduct annual evaluations of your continuous emission monitoring systems...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-28
... Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources AGENCY... direct final rule titled ``Quality Assurance Requirements for Continuous Opacity Monitoring Systems at...--Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources Docket, EPA...
Unconsummated marriages: a separate and different clinical entity.
Gindin, Leon Roberto; Resnicoff, Diana
2002-01-01
We bring our experience in the treatment of unconsummated marriages (UM). We postulate that it is an independent clinical entity. Since 1991, 199 couples with UM have sought treatment in our center in Buenos Aires. A new approach to this problem is based on an intensive treatment session that lasts a whole day and a pledge to pay only if therapy succeeds. The outcome was a success (97%) with coitus consummation. We make a long-term follow up. The advantages are the brevity of the treatment and lack of desertions. We postulate that UM cannot be approached with an individual perspective or with the usual psychotherapy techniques.
A remote condition monitoring system for wind-turbine based DG systems
NASA Astrophysics Data System (ADS)
Ma, X.; Wang, G.; Cross, P.; Zhang, X.
2012-05-01
In this paper, a remote condition monitoring system is proposed, which fundamentally consists of real-time monitoring modules on the plant side, a remote support centre and the communications between them. The paper addresses some of the key issues related on the monitoring system, including i) the implementation and configuration of a VPN connection, ii) an effective database system to be able to handle huge amount of monitoring data, and iii) efficient data mining techniques to convert raw data into useful information for plant assessment. The preliminary results have demonstrated that the proposed system is practically feasible and can be deployed to monitor the emerging new energy generation systems.
Demonstration of subsidence monitoring system
NASA Astrophysics Data System (ADS)
Conroy, P. J.; Gyarmaty, J. H.; Pearson, M. L.
1981-06-01
Data on coal mine subsidence were studied as a basis for the development of subsidence control technology. Installation, monitoring, and evaluation of three subsidence monitoring instrument systems were examined: structure performance, performance of supported systems, and performance of caving systems. Objectives of the instrument program were: (1) to select, test, assemble, install, monitor, and maintain all instrumentation required for implementing the three subsidence monitoring systems; and (2) to evaluate performance of each instrument individually and as part of the appropriate monitoring system or systems. The use of an automatic level and a rod extensometer for measuring structure performance, and the automatic level, steel tape extensometer, FPBX, FPBI, USBM borehole deformation gauge, and vibrating wire stressmeters for measuring the performance of caving systems are recommended.
Phytoplankton nutrient limitation was studied in a sub-estuary of lower Pensacola Bay using several techniques. Results for <5 um and . 5 um phytoplankton were similar. Nutrient-addition bioassays indicated year-round nutrient limitation, in contrast to seasonal patterns often ...
Unit 5, STA. 50+00+RB, retaining wall at First U.M. Churchdetail ...
Unit 5, STA. 50+00+RB, retaining wall at First U.M. Church-detail - Johnstown Local Flood Protection Project, Beginning on Conemaugh River approx 3.8 miles downstream from confluence of Little Conemaugh & Stony Creek Rivers at Johnstown, Johnstown, Cambria County, PA
21 CFR 880.2420 - Electronic monitor for gravity flow infusion systems.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electronic monitor for gravity flow infusion... and Personal Use Monitoring Devices § 880.2420 Electronic monitor for gravity flow infusion systems. (a) Identification. An electronic monitor for gravity flow infusion systems is a device used to...
21 CFR 880.2420 - Electronic monitor for gravity flow infusion systems.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Electronic monitor for gravity flow infusion... and Personal Use Monitoring Devices § 880.2420 Electronic monitor for gravity flow infusion systems. (a) Identification. An electronic monitor for gravity flow infusion systems is a device used to...
21 CFR 880.2420 - Electronic monitor for gravity flow infusion systems.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Electronic monitor for gravity flow infusion... and Personal Use Monitoring Devices § 880.2420 Electronic monitor for gravity flow infusion systems. (a) Identification. An electronic monitor for gravity flow infusion systems is a device used to...
21 CFR 880.2420 - Electronic monitor for gravity flow infusion systems.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Electronic monitor for gravity flow infusion... and Personal Use Monitoring Devices § 880.2420 Electronic monitor for gravity flow infusion systems. (a) Identification. An electronic monitor for gravity flow infusion systems is a device used to...
21 CFR 880.2420 - Electronic monitor for gravity flow infusion systems.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Electronic monitor for gravity flow infusion... and Personal Use Monitoring Devices § 880.2420 Electronic monitor for gravity flow infusion systems. (a) Identification. An electronic monitor for gravity flow infusion systems is a device used to...
Linguistic camouflage in girls with autism spectrum disorder.
Parish-Morris, Julia; Liberman, Mark Y; Cieri, Christopher; Herrington, John D; Yerys, Benjamin E; Bateman, Leila; Donaher, Joseph; Ferguson, Emily; Pandey, Juhi; Schultz, Robert T
2017-01-01
Autism spectrum disorder (ASD) is diagnosed more frequently in boys than girls, even when girls are equally symptomatic. Cutting-edge behavioral imaging has detected "camouflaging" in girls with ASD, wherein social behaviors appear superficially typical, complicating diagnosis. The present study explores a new kind of camouflage based on language differences. Pauses during conversation can be filled with words like UM or UH, but research suggests that these two words are pragmatically distinct (e.g., UM is used to signal longer pauses, and may correlate with greater social communicative sophistication than UH). Large-scale research suggests that women and younger people produce higher rates of UM during conversational pauses than do men and older people, who produce relatively more UH. Although it has been argued that children and adolescents with ASD use UM less often than typical peers, prior research has not included sufficient numbers of girls to examine whether sex explains this effect. Here, we explore UM vs. UH in school-aged boys and girls with ASD, and ask whether filled pauses relate to dimensional measures of autism symptom severity. Sixty-five verbal school-aged participants with ASD (49 boys, 16 girls, IQ estimates in the average range) participated, along with a small comparison group of typically developing children (8 boys, 9 girls). Speech samples from the Autism Diagnostic Observation Schedule were orthographically transcribed and time-aligned, with filled pauses marked. Parents completed the Social Communication Questionnaire and the Vineland Adaptive Behavior Scales. Girls used UH less often than boys across both diagnostic groups. UH suppression resulted in higher UM ratios for girls than boys, and overall filled pause rates were higher for typical children than for children with ASD. Higher UM ratios correlated with better socialization in boys with ASD, but this effect was driven by increased use of UH by boys with greater symptoms. Pragmatic language markers distinguish girls and boys with ASD, mirroring sex differences in the general population. One implication of this finding is that typical-sounding disfluency patterns (i.e., reduced relative UH production leading to higher UM ratios) may normalize the way girls with ASD sound relative to other children, serving as "linguistic camouflage" for a naïve listener and distinguishing them from boys with ASD. This first-of-its-kind study highlights the importance of continued commitment to understanding how sex and gender change the way that ASD manifests, and illustrates the potential of natural language to contribute to objective "behavioral imaging" diagnostics for ASD.
Telescópio de patrulhamento solar em 12 GHz
NASA Astrophysics Data System (ADS)
Utsumi, F.; Costa, J. E. R.
2003-08-01
O telescópio de patrulhamento solar é um instrumento dedicado à observação de explosões solares com início de suas operações em janeiro de 2002, trabalhando próximo ao pico de emissão do espectro girossincrotrônico (12 GHz). Trata-se de um arranjo de três antenas concebido para a detecção de explosões e determinação em tempo real da localização da região emissora. Porém, desde sua implementação em uma montagem equatorial movimentada por um sistema de rotação constante (15 graus/hora) o rastreio apresentou pequenas variações de velocidade e folgas nas caixas de engrenagens. Assim, tornou-se necessária a construção de um sistema de correção automática do apontamento que era de fundamental importância para os objetivos do projeto. No segundo semestre de 2002 empreendemos uma série de tarefas com o objetivo de automatizar completamente o rastreio, a calibração, a aquisição de dados, controle de ganhos, offsets e transferência dos dados pela internet através de um projeto custeado pela FAPESP. O rastreio automático é realizado através de um inversor que controla a freqüência da rede de alimentação do motor de rastreio podendo fazer micro-correções na direção leste-oeste conforme os radiômetros desta direção detectem uma variação relativa do sinal. Foi adicionado também um motor na direção da declinação para correção automática da variação da direção norte-sul. Após a implementação deste sistema a precisão do rastreio melhorou para um desvio máximo de 30 segundos de arco, o que está muito bom para este projeto. O Telescópio se encontra em funcionamento automático desde março de 2003 e já conta com várias explosões observadas após a conclusão desta fase de automação. Estamos apresentando as explosões mais intensas do período e com as suas respectivas posições no disco solar.
Design and characterization of dielectric subwavelength focusing lens with polarization dependence
NASA Astrophysics Data System (ADS)
Kim, Sung W.; Pang, Lin; Fainman, Yeshaiahu
2016-03-01
We introduce and develop design, fabrication and characterization methodology for engineering the effective refractive index of a composite dielectric planar surface created by controlling the density of deeply subwavelength low index nanoholes (e.g., air) in a high index dielectric layer (e.g., Si). The nanoscale properties of a composite dielectric layer allows for full control of the optical wavefront phase by designing arbitrary space-variant refractive index profiles. We present the composite dielectric metasurface microlens exploiting symmetric design to achieve polarization invariant impulse response, and use asymmetric design to demonstrate polarization sensitive impulse response of the lens. This composite dielectric layers lenses were fabricated by patterning nanohole distributions on a dielectric surface and etching to submicron depths. Our dielectric microlens with asymmetric distribution of neff (neff x ≠ neff y) demonstrates a graded index lens with polarization dependent focusing with of 32um and 22 um for linearly x- and y-polarized light, respectively operating at a wavelength of λ = 1550nm. We also show numerically and demonstrate experimentally achromatic performance of the devices operating in the wavelength range of 1500nm - 1900nm with FWHM of the focal spots of about 4um. Namely, we have constructed a graded index lens that can overcome diffraction effects even when aperture/wavelength (D/λ) is smaller than 40. The demonstrated novel approach to engineer dielectric composite nanosurfaces has the potential to realize arbitrary phase functions with minimal insertion loss, submicron thickness and miniaturization to reduce element size and weight, and may have a significant impact on numerous miniature imaging systems applications.
Study of the kinematic variables of unilateral and habitual mastication of healthy individuals.
Pasinato, Fernanda; Oliveira, Andréia Gussi de; Santos-Couto-Paz, Clarissa C; Zeredo, Jorge Luis Lopes; Bolzan, Geovana de Paula; Macedo, Sergio Bruzadelli; Corrêa, Eliane C R
2017-03-30
To describe and compare the temporal-spatial kinematic variables of mandibular movement during deliberate unilateral and habitual mastication in healthy young-adult individuals. The study sample was composed of eight male healthy volunteers aged 19 to 24 years. The kinematic data were obtained using a motion analysis system - Qualisys Track Manager (QTM) ProReflex MCU. Recordings were performed during deliberate unilateral mastication (UM) and habitual mastication (HM) of firm-consistency gummy candy. The following variables were analyzed: (1) masticatory sequence: duration, number of masticatory cycles, and chewing rate; (2) masticatory cycle: duration, vertical and medial-lateral mandibular range of motion in relation to the skull, and maximum velocity during the opening and closing phases. Data of the variables were compared during UM and HM by the paired t test, and the effect sizes ('d' Cohen) were calculated. Regarding the variables of the masticatory sequence, smaller chewing rate was observed for UM compared with that for HM (1.19±0.21Hz and 1.29±0.16Hz, respectively, p=0.004, d=0.53). Smaller values of maximum velocity during the opening (MU=67.4 mm/s and MH=80.02, p=0.053, d=0.80) and closing (MU=71.77±9.35mm/s and MH=3.51±7mm/s, p=0.014, d=0.79) phases of the masticatory cycle were observed in deliberate unilateral mastication compared with those in habitual mastication. Kinematic variables associated with the sequence and cycle of mastication are influenced by the chewing pattern adopted - deliberate unilateral or habitual.
40 CFR 60.2939 - What continuous emission monitoring systems must I install?
Code of Federal Regulations, 2012 CFR
2012-07-01
... systems must I install? 60.2939 Section 60.2939 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... and Qualification Monitoring § 60.2939 What continuous emission monitoring systems must I install? (a) You must install, calibrate, maintain, and operate continuous emission monitoring systems for carbon...
The effect of 648 nm diode laser irradiation on second messengers in senescent human keratinocytes
NASA Astrophysics Data System (ADS)
Hawkins Evans, D.; Abrahamse, H.
2009-02-01
Background/purpose: Stress induced premature senescence (SIPS) is defined as the long-term effect of subcytotoxic stress on proliferative cell types. Cells in SIPS display differences at the level of protein expression which affect energy metabolism, defense systems, redox potential, cell morphology and transduction pathways. This study aimed to determine the effect of laser irradiation on second messengers in senescent cells and to establish if that effect can be directly linked to changes in cellular function such as cell viability or proliferation. Materials and Methods: Human keratinocyte cell cultures were modified to induce premature senescence using repeated sub-lethal stresses of 200 uM H2O2 or 5% OH every day for four days with two days recovery. SIPS was confirmed by senescence-associated β-galactosidase staining. Control conditions included normal, repeated stress of 500 uM H2O2 to induce apoptosis and 200 uM PBN as an anti-oxidant or free radical scavenger. Cells were irradiated with 1.5 J/cm2 on day 1 and 4 using a 648 nm diode laser (3.3 mW/cm2) and cellular responses were measured 1 h post irradiation. The affect on second messengers was assessed by measuring cAMP, cGMP, nitric oxide and intracellular calcium (Ca2+) while functional changes were assessed using cell morphology, ATP cell viability, LDH membrane integrity and WST-1 cell proliferation. Results: Results indicate an increase in NO and a decrease in cGMP and Ca2+ in 200 uM H2O2 irradiated cells while PBN irradiated cells showed a decrease in cAMP and an increase in ATP viability and cell proliferation. Conclusion: Laser irradiation influences cell signaling which ultimately changes the biological function of senescent cells. If laser therapy can stimulate the biological function of senescent cells it may be beneficial to conditions such as immune senescence, skin ageing, muscle atrophy, premature ageing of arteries in patients with advanced heart disease, neurodegenerative disorders and chronic renal failure.
NASA Astrophysics Data System (ADS)
Zhou, Chuan; Chan, Heang-Ping; Guo, Yanhui; Wei, Jun; Chughtai, Aamer; Hadjiiski, Lubomir M.; Sundaram, Baskaran; Patel, Smita; Kuriakose, Jean W.; Kazerooni, Ella A.
2013-03-01
The curved planar reformation (CPR) method re-samples the vascular structures along the vessel centerline to generate longitudinal cross-section views. The CPR technique has been commonly used in coronary CTA workstation to facilitate radiologists' visual assessment of coronary diseases, but has not yet been used for pulmonary vessel analysis in CTPA due to the complicated tree structures and the vast network of pulmonary vasculature. In this study, a new curved planar reformation and optimal path tracing (CROP) method was developed to facilitate feature extraction and false positive (FP) reduction and improve our PE detection system. PE candidates are first identified in the segmented pulmonary vessels at prescreening. Based on Dijkstra's algorithm, the optimal path (OP) is traced from the pulmonary trunk bifurcation point to each PE candidate. The traced vessel is then straightened and a reformatted volume is generated using CPR. Eleven new features that characterize the intensity, gradient, and topology are extracted from the PE candidate in the CPR volume and combined with the previously developed 9 features to form a new feature space for FP classification. With IRB approval, CTPA of 59 PE cases were retrospectively collected from our patient files (UM set) and 69 PE cases from the PIOPED II data set with access permission. 595 and 800 PEs were manually marked by experienced radiologists as reference standard for the UM and PIOPED set, respectively. At a test sensitivity of 80%, the average FP rate was improved from 18.9 to 11.9 FPs/case with the new method for the PIOPED set when the UM set was used for training. The FP rate was improved from 22.6 to 14.2 FPs/case for the UM set when the PIOPED set was used for training. The improvement in the free response receiver operating characteristic (FROC) curves was statistically significant (p<0.05) by JAFROC analysis, indicating that the new features extracted from the CROP method are useful for FP reduction.
Evaluation of Nonpoint-Source Contamination, Wisconsin: Selected Topics for Water Year 1995
Owens, D.W.; Corsi, Steven R.; Rappold, K.F.
1997-01-01
The objective of the watershed-management evaluation monitoring program in Wisconsin is to evaluate the effectiveness of best-management practices (BMP's) for controlling nonpoint-source contamination in eight rural and four urban watersheds. This report, the fourth in an annual series of reports, presents a summary of the data collected for the program by the U.S. Geological Survey and the results of several detailed analyses of the data. To complement assessments of water quality, a land-use and BMP inventory is ongoing for 12 evaluation monitoring projects to track nonpoint sources of contamination in each watershed and to document implementation of BMP's that were designed to cause changes in the water quality of streams. Each year, updated information is gathered, mapped, and stored in a geographic-information-system data base. Summaries of land-use, BMP implementation, and water-quality data collected during water years 1989-95 are presented. Storm loads, snowmelt-period loads, and annual loads of suspended sediment and total phosphorus are summarized for eight rural sites. Storm-load data for suspended solids, total phosphorus, total recoverable lead, copper, zinc, and cadmium are summarized for four urban sites. Quality-assurance and quality-control (QA/QC) samples were collected at the eight rural sites to evaluate inorganic sample contamination and at one urban site to evaluate sample-collection and filtration techniques for polycyclic aromatic hydrocarbons (PAR's). Some suspended solids and fecal coliform contamination was detected at the rural sites. Corrective actions will be taken to address this contamination. Evaluation of PAR sample-collection techniques did not uncover any deficiencies, but the small amount of data collected was not sufficient to draw any definite conclusions. Evaluation of PAR filtration techniques indicate that water-sample filtration with O.7-um glass-fiber filters in an aluminum filter unit does not result in significant loss of PAR.
Jefferds, Maria Elena D; Flores-Ayala, Rafael
2015-12-01
Lack of monitoring capacity is a key barrier for nutrition interventions and limits programme management, decision making and programme effectiveness in many low-income and middle-income countries. A 2011 global assessment reported lack of monitoring capacity was the top barrier for home fortification interventions, such as micronutrient powders or lipid-based nutrient supplements. A Manual for Developing and Implementing Monitoring Systems for Home Fortification Interventions was recently disseminated. It is comprehensive and describes monitoring concepts and frameworks and includes monitoring tools and worksheets. The monitoring manual describes the steps of developing and implementing a monitoring system for home fortification interventions, including identifying and engaging stakeholders; developing a programme description including logic model and logical framework; refining the purpose of the monitoring system, identifying users and their monitoring needs; describing the design of the monitoring system; developing indicators; describing the core components of a comprehensive monitoring plan; and considering factors related to stage of programme development, sustainability and scale up. A fictional home fortification example is used throughout the monitoring manual to illustrate these steps. The monitoring manual is a useful tool to support the development and implementation of home fortification intervention monitoring systems. In the context of systematic capacity gaps to design, implement and monitor nutrition interventions in many low-income and middle-income countries, the dissemination of new tools, such as monitoring manuals may have limited impact without additional attention to strengthening other individual, organisational and systems levels capacities. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.
DOT National Transportation Integrated Search
2017-12-01
For the incident response operations to be appreciated by the general public, it is essential that responsible highway agencies be capable of providing the estimated clearance duration of a detected incident at the level sufficiently reliable for mot...
NASA Astrophysics Data System (ADS)
Laban, Shaban; El-Desouky, Ali
2010-05-01
The heterogeneity of the distributed processing systems, monitored data and resources is an obvious challenge in monitoring the data of International Monitoring System (IMS) of the Comprehensive Nuclear Test-Ban Treaty organization (CTBTO). Processing engineers, analysts, operators and other interested parties seek for intelligent tools and software that hide the underlying complexity of the systems, allowing them to manage the operation and monitoring the systems at a higher level, focusing on what the expected behavior and results should be instead of how to specifically achieve it. Also, it is needed to share common understanding of the structure of organization information, data, and products among staff, software agents, and policy making organs. Additionally, introducing new monitoring object or system should not complicate the overall system and should be feasible. An ontologybased approach is presented in this paper aiming to support monitoring real-time data processing and supervising the various system resources, focusing on integrating and sharing same knowledge and status information of the system among different environments. The results of a prototype framework is presented and analyzed.
General Purpose Data-Driven Online System Health Monitoring with Applications to Space Operations
NASA Technical Reports Server (NTRS)
Iverson, David L.; Spirkovska, Lilly; Schwabacher, Mark
2010-01-01
Modern space transportation and ground support system designs are becoming increasingly sophisticated and complex. Determining the health state of these systems using traditional parameter limit checking, or model-based or rule-based methods is becoming more difficult as the number of sensors and component interactions grows. Data-driven monitoring techniques have been developed to address these issues by analyzing system operations data to automatically characterize normal system behavior. System health can be monitored by comparing real-time operating data with these nominal characterizations, providing detection of anomalous data signatures indicative of system faults, failures, or precursors of significant failures. The Inductive Monitoring System (IMS) is a general purpose, data-driven system health monitoring software tool that has been successfully applied to several aerospace applications and is under evaluation for anomaly detection in vehicle and ground equipment for next generation launch systems. After an introduction to IMS application development, we discuss these NASA online monitoring applications, including the integration of IMS with complementary model-based and rule-based methods. Although the examples presented in this paper are from space operations applications, IMS is a general-purpose health-monitoring tool that is also applicable to power generation and transmission system monitoring.
Rajan, J Pandia; Rajan, S Edward
2018-01-01
Wireless physiological signal monitoring system designing with secured data communication in the health care system is an important and dynamic process. We propose a signal monitoring system using NI myRIO connected with the wireless body sensor network through multi-channel signal acquisition method. Based on the server side validation of the signal, the data connected to the local server is updated in the cloud. The Internet of Things (IoT) architecture is used to get the mobility and fast access of patient data to healthcare service providers. This research work proposes a novel architecture for wireless physiological signal monitoring system using ubiquitous healthcare services by virtual Internet of Things. We showed an improvement in method of access and real time dynamic monitoring of physiological signal of this remote monitoring system using virtual Internet of thing approach. This remote monitoring and access system is evaluated in conventional value. This proposed system is envisioned to modern smart health care system by high utility and user friendly in clinical applications. We claim that the proposed scheme significantly improves the accuracy of the remote monitoring system compared to the other wireless communication methods in clinical system.
NASA Astrophysics Data System (ADS)
Heintze, Joachim
In diesem Kapitel werden wir uns vornehmlich mit zwei Vorgängen befassen, ohne die das Erreichen des thermischen Gleichgewichts und die Veränderung des thermischen Zustands eines Systems unmöglich wäre: Wärmeleitung und Diffusion. Bei der Wärmeleitung wird die kinetische Energie der Teilchen durch Stöße auf die Nachbarn übertragen: Es handelt sich um den Transport von Wärmeenergie. Unter Diffusion versteht man den Transport von Molekülen aufgrund ihrer Wärmebewegung. Sie tritt in Erscheinung, wenn in einem System verschiedene Arten von Molekülen vorhanden und ungleichmäßig verteilt sind.
21 CFR 876.1725 - Gastrointestinal motility monitoring system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Gastrointestinal motility monitoring system. 876... Gastrointestinal motility monitoring system. (a) Identification. A gastrointestinal motility monitoring system is a device used to measure peristalic activity or pressure in the stomach or esophagus by means of a probe...
Code of Federal Regulations, 2010 CFR
2010-07-01
... emission monitoring systems are operating correctly? 60.1730 Section 60.1730 Protection of Environment... continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or carbon dioxide...
Code of Federal Regulations, 2014 CFR
2014-07-01
... emission monitoring systems are operating correctly? 60.1730 Section 60.1730 Protection of Environment... continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or carbon dioxide...
Code of Federal Regulations, 2010 CFR
2010-07-01
... emission monitoring systems are operating correctly? 62.15185 Section 62.15185 Protection of Environment... make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or...
Code of Federal Regulations, 2012 CFR
2012-07-01
... emission monitoring systems are operating correctly? 60.2940 Section 60.2940 Protection of Environment... monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure carbon monoxide and oxygen. (b) Complete your...
Code of Federal Regulations, 2012 CFR
2012-07-01
... emission monitoring systems are operating correctly? 60.3039 Section 60.3039 Protection of Environment... emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure carbon monoxide and oxygen. (b...
Code of Federal Regulations, 2012 CFR
2012-07-01
... emission monitoring systems are operating correctly? 60.1730 Section 60.1730 Protection of Environment... continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or carbon dioxide...
Code of Federal Regulations, 2010 CFR
2010-07-01
... emission monitoring systems are operating correctly? 60.2940 Section 60.2940 Protection of Environment... monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure carbon monoxide and oxygen. (b) Complete your...
Code of Federal Regulations, 2011 CFR
2011-07-01
... emission monitoring systems are operating correctly? 60.2940 Section 60.2940 Protection of Environment... monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure carbon monoxide and oxygen. (b) Complete your...
Code of Federal Regulations, 2013 CFR
2013-07-01
... emission monitoring systems are operating correctly? 60.1730 Section 60.1730 Protection of Environment... continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or carbon dioxide...
Code of Federal Regulations, 2011 CFR
2011-07-01
... emission monitoring systems are operating correctly? 60.3039 Section 60.3039 Protection of Environment... emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure carbon monoxide and oxygen. (b...
Code of Federal Regulations, 2014 CFR
2014-07-01
... emission monitoring systems are operating correctly? 62.15185 Section 62.15185 Protection of Environment... make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or...
Code of Federal Regulations, 2014 CFR
2014-07-01
... emission monitoring systems are operating correctly? 60.3039 Section 60.3039 Protection of Environment... emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure carbon monoxide and oxygen. (b...
Code of Federal Regulations, 2010 CFR
2010-07-01
... emission monitoring systems are operating correctly? 60.3039 Section 60.3039 Protection of Environment... emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure carbon monoxide and oxygen. (b...
Code of Federal Regulations, 2011 CFR
2011-07-01
... emission monitoring systems are operating correctly? 60.1730 Section 60.1730 Protection of Environment... continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or carbon dioxide...
Code of Federal Regulations, 2012 CFR
2012-07-01
... emission monitoring systems are operating correctly? 62.15185 Section 62.15185 Protection of Environment... make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or...
Code of Federal Regulations, 2013 CFR
2013-07-01
... emission monitoring systems are operating correctly? 60.3039 Section 60.3039 Protection of Environment... emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure carbon monoxide and oxygen. (b...
Code of Federal Regulations, 2011 CFR
2011-07-01
... emission monitoring systems are operating correctly? 62.15185 Section 62.15185 Protection of Environment... make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or...
Code of Federal Regulations, 2013 CFR
2013-07-01
... emission monitoring systems are operating correctly? 62.15185 Section 62.15185 Protection of Environment... make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or...
50 CFR 665.19 - Vessel monitoring system.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 50 Wildlife and Fisheries 13 2012-10-01 2012-10-01 false Vessel monitoring system. 665.19 Section... monitoring system. (a) Applicability. The holder of any of the following permits is subject to the vessel monitoring system requirements in this part: (1) Hawaii longline limited access permit issued pursuant to...
50 CFR 665.19 - Vessel monitoring system.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 50 Wildlife and Fisheries 13 2013-10-01 2013-10-01 false Vessel monitoring system. 665.19 Section... monitoring system. (a) Applicability. The holder of any of the following permits is subject to the vessel monitoring system requirements in this part: (1) Hawaii longline limited access permit issued pursuant to...
50 CFR 665.19 - Vessel monitoring system.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 50 Wildlife and Fisheries 11 2011-10-01 2011-10-01 false Vessel monitoring system. 665.19 Section... monitoring system. (a) Applicability. The holder of any of the following permits is subject to the vessel monitoring system requirements in this part: (1) Hawaii longline limited access permit issued pursuant to...
40 CFR 60.1740 - What is my schedule for evaluating continuous emission monitoring systems?
Code of Federal Regulations, 2011 CFR
2011-07-01
... continuous emission monitoring systems? 60.1740 Section 60.1740 Protection of Environment ENVIRONMENTAL... evaluating continuous emission monitoring systems? (a) Conduct annual evaluations of your continuous emission monitoring systems no more than 13 months after the previous evaluation was conducted. (b) Evaluate your...
49 CFR 385.715 - Duration of safety monitoring system.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 5 2011-10-01 2011-10-01 false Duration of safety monitoring system. 385.715... SAFETY FITNESS PROCEDURES Safety Monitoring System for Non-North American Carriers § 385.715 Duration of safety monitoring system. (a) Each non-North America-domiciled carrier subject to this subpart will...
50 CFR 665.19 - Vessel monitoring system.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 50 Wildlife and Fisheries 9 2010-10-01 2010-10-01 false Vessel monitoring system. 665.19 Section... monitoring system. (a) Applicability. The holder of any of the following permits is subject to the vessel monitoring system requirements in this part: (1) Hawaii longline limited access permit issued pursuant to...
49 CFR 385.117 - Duration of safety monitoring system.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 5 2010-10-01 2010-10-01 false Duration of safety monitoring system. 385.117... SAFETY FITNESS PROCEDURES Safety Monitoring System for Mexico-Domiciled Carriers § 385.117 Duration of safety monitoring system. (a) Each Mexico-domiciled carrier subject to this subpart will remain in the...
49 CFR 385.117 - Duration of safety monitoring system.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 5 2011-10-01 2011-10-01 false Duration of safety monitoring system. 385.117... SAFETY FITNESS PROCEDURES Safety Monitoring System for Mexico-Domiciled Carriers § 385.117 Duration of safety monitoring system. (a) Each Mexico-domiciled carrier subject to this subpart will remain in the...
40 CFR 62.15195 - What is my schedule for evaluating continuous emission monitoring systems?
Code of Federal Regulations, 2010 CFR
2010-07-01
... continuous emission monitoring systems? 62.15195 Section 62.15195 Protection of Environment ENVIRONMENTAL... evaluating continuous emission monitoring systems? (a) Conduct annual evaluations of your continuous emission monitoring systems no more than 13 months after the previous evaluation was conducted. (b) Evaluate your...
49 CFR 385.715 - Duration of safety monitoring system.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 5 2010-10-01 2010-10-01 false Duration of safety monitoring system. 385.715... SAFETY FITNESS PROCEDURES Safety Monitoring System for Non-North American Carriers § 385.715 Duration of safety monitoring system. (a) Each non-North America-domiciled carrier subject to this subpart will...
40 CFR 62.15195 - What is my schedule for evaluating continuous emission monitoring systems?
Code of Federal Regulations, 2011 CFR
2011-07-01
... continuous emission monitoring systems? 62.15195 Section 62.15195 Protection of Environment ENVIRONMENTAL... evaluating continuous emission monitoring systems? (a) Conduct annual evaluations of your continuous emission monitoring systems no more than 13 months after the previous evaluation was conducted. (b) Evaluate your...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-23
... Collection; Comment Request; Western Region Vessel Monitoring System and Pre-Trip Reporting Requirements... information or new problems in the fisheries. Vessel Monitoring System (VMS) units will facilitate enforcement... monitoring system (VMS) activation reports, 15 minutes; pre-trip reports, 5 minutes. Estimated Burden Hours...
Evaluation of the Monitor-CTA Automatic Vehicle Monitoring System
DOT National Transportation Integrated Search
1974-03-01
In June 1972 the Urban Mass Transportation Administration requested that the Transportation System Center of DOT perform an evaluation of the CTA (Chicago Transit Authority) Monitor-Automatic Vehicle Monitor (AVM) system. TSC planned the overall eval...
Automated monitoring of recovered water quality
NASA Technical Reports Server (NTRS)
Misselhorn, J. E.; Hartung, W. H.; Witz, S. W.
1974-01-01
Laboratory prototype water quality monitoring system provides automatic system for online monitoring of chemical, physical, and bacteriological properties of recovered water and for signaling malfunction in water recovery system. Monitor incorporates whenever possible commercially available sensors suitably modified.
[Implementation of Oncomelania hupensis monitoring system based on Baidu Map].
Zhi-Hua, Chen; Yi-Sheng, Zhu; Zhi-Qiang, Xue; Xue-Bing, Li; Yi-Min, Ding; Li-Jun, Bi; Kai-Min, Gao; You, Zhang
2017-10-25
To construct the Oncomelania hupensis snail monitoring system based on the Baidu Map. The environmental basic information about historical snail environment and existing snail environment, etc. was collected with the monitoring data about different kinds of O. hupensis snails, and then the O. hupensis snail monitoring system was built. Geographic Information System (GIS) and the electronic fence technology and Application Program Interface (API) were applied to set up the electronic fence of the snail surveillance environments, and the electronic fence was connected to the database of the snail surveillance. The O. hupensis snail monitoring system based on the Baidu Map were built up, including three modules of O. hupensis Snail Monitoring Environmental Database, Dynamic Monitoring Platform and Electronic Map. The information about monitoring O. hupensis snails could be obtained through the computer and smartphone simultaneously. The O. hupensis snail monitoring system, which is based on Baidu Map, is a visible platform to follow the process of snailsearching and molluscaciding.