Morgellons disease, illuminating an undefined illness: a case series.
Harvey, William T; Bransfield, Robert C; Mercer, Dana E; Wright, Andrew J; Ricchi, Rebecca M; Leitao, Mary M
2009-07-01
This review of 25 consecutive patients with Morgellons disease (MD) was undertaken for two primary and extremely fundamental reasons. For semantic accuracy, there is only one "proven" MD patient: the child first given that label. The remainder of inclusive individuals adopted the label based on related descriptions from 1544 through 1884, an internet description quoted from Sir Thomas Browne (1674), or was given the label by practitioners using similar sources. Until now, there has been no formal characterization of MD from detailed examination of all body systems. Our second purpose was to differentiate MD from Delusions of Parasitosis (DP), another "informal" label that fit most of our MD patients. How we defined and how we treated these patients depended literally on factual data that would determine outcome. How they were labeled in one sense was irrelevant, except for the confusing conflict rampant in the medical community, possibly significantly skewing treatment outcomes. Clinical information was collected from 25 of 30 consecutive self-defined patients with Morgellons disease consisting of laboratory data, medical history and physical examination findings. Abnormalities were quantified and grouped by system, then compared and summarized, but the numbers were too small for more complex mathematical analysis. The quantification of physical and laboratory abnormalities allowed at least the creation of a practical clinical boundary, separating probable Morgellons from non-Morgellons patients. All the 25 patients studied meet the most commonly used DP definitions. These data suggest Morgellons disease can be characterized as a physical human illness with an often-related delusional component in adults. All medical histories support that behavioral aberrancies onset only after physical symptoms. The identified abnormalities include both immune deficiency and chronic inflammatory markers that correlate strongly with immune cytokine excess. The review of 251 current NLM DP references leads us to the possibility that Morgellons disease and DP are grossly truncated labels of the same illness but with the reversal of the cause-effect order. Further, the patients' data suggest that both illnesses have an infectious origin.
Morgellons disease, illuminating an undefined illness: a case series
2009-01-01
Introduction This review of 25 consecutive patients with Morgellons disease (MD) was undertaken for two primary and extremely fundamental reasons. For semantic accuracy, there is only one "proven" MD patient: the child first given that label. The remainder of inclusive individuals adopted the label based on related descriptions from 1544 through 1884, an internet description quoted from Sir Thomas Browne (1674), or was given the label by practitioners using similar sources. Until now, there has been no formal characterization of MD from detailed examination of all body systems. Our second purpose was to differentiate MD from Delusions of Parasitosis (DP), another "informal" label that fit most of our MD patients. How we defined and how we treated these patients depended literally on factual data that would determine outcome. How they were labeled in one sense was irrelevant, except for the confusing conflict rampant in the medical community, possibly significantly skewing treatment outcomes. Case presentation Clinical information was collected from 25 of 30 consecutive self-defined patients with Morgellons disease consisting of laboratory data, medical history and physical examination findings. Abnormalities were quantified and grouped by system, then compared and summarized, but the numbers were too small for more complex mathematical analysis. The quantification of physical and laboratory abnormalities allowed at least the creation of a practical clinical boundary, separating probable Morgellons from non-Morgellons patients. All the 25 patients studied meet the most commonly used DP definitions. Conclusions These data suggest Morgellons disease can be characterized as a physical human illness with an often-related delusional component in adults. All medical histories support that behavioral aberrancies onset only after physical symptoms. The identified abnormalities include both immune deficiency and chronic inflammatory markers that correlate strongly with immune cytokine excess. The review of 251 current NLM DP references leads us to the possibility that Morgellons disease and DP are grossly truncated labels of the same illness but with the reversal of the cause-effect order. Further, the patients' data suggest that both illnesses have an infectious origin. PMID:19830222
The mystery of Morgellons disease: infection or delusion?
Savely, Virginia R; Leitao, Mary M; Stricker, Raphael B
2006-01-01
Morgellons disease is a mysterious skin disorder that was first described more than 300 years ago. The disease is characterized by fiber-like strands extruding from the skin in conjunction with various dermatologic and neuropsychiatric symptoms. In this respect, Morgellons disease resembles and may be confused with delusional parasitosis. The association with Lyme disease and the apparent response to antibacterial therapy suggest that Morgellons disease may be linked to an undefined infectious process. Further clinical and molecular research is needed to unlock the mystery of Morgellons disease.
HYPNOSIS IN THE TREATMENT OF MORGELLONS DISEASE: A Case Study1
Gartner, Ashley M.; Dolan, Sara L.; Stanford, Matthew S.; Elkins, Gary R.
2014-01-01
Morgellons Disease is a condition involving painful skin lesions, fibrous growths protruding from the skin, and subcutaneous stinging and burning sensations, along with symptoms of anxiety, depression, fatigue, and memory and attention deficits. The etiological and physiological bases of these symptoms are unclear, making the diagnosis controversial and challenging to treat. There are currently no established treatments for Morgellons Disease. The following case example depicts treatment of a woman with Morgellons Disease using hypnotherapy. Data from this case example suggest that hypnotherapy is a promising intervention for the physical and psychological symptoms associated with Morgellons Disease. PMID:21390982
Hypnosis in the treatment of Morgellons disease: a case study.
Gartner, Ashley M; Dolan, Sara L; Stanford, Matthew S; Elkins, Gary R
2011-04-01
Morgellons Disease is a condition involving painful skin lesions, fibrous growths protruding from the skin, and subcutaneous stinging and burning sensations, along with symptoms of anxiety, depression, fatigue, and memory and attention deficits. The etiological and physiological bases of these symptoms are unclear, making the diagnosis controversial and challenging to treat. There are currently no established treatments for Morgellons Disease. The following case example depicts treatment of a woman with Morgellons Disease using hypnotherapy. Data from this case example suggest that hypnotherapy is a promising intervention for the physical and psychological symptoms associated with Morgellons Disease.
Disorder or delusion? Living with Morgellons disease.
Simpson, Lindsay; Baier, Marjorie
2009-08-01
Whether Morgellons disease is a delusional disorder or even a disease has been a mystery for more than 300 years. Symptoms of Morgellons include crawling and stinging sensations, feeling of "bugs" and/or fiber-like material beneath the skin, disabling fatigue, and memory loss. The cause, transmission, and treatment are unknown. Research about Morgellons is staggeringly sparse and limited in scope. However, in recent years, discussion about Morgellons has become more common because of the Internet and online support groups. Mental health professionals and the general public need to be aware of the signs, symptoms, and treatment of this disease. Focusing on the disease and listening to patients can make a difference in the way health care professionals provide the best possible care for people with Morgellons. Copyright (c) 2009, SLACK Incorporated.
Characterization and evolution of dermal filaments from patients with Morgellons disease.
Middelveen, Marianne J; Mayne, Peter J; Kahn, Douglas G; Stricker, Raphael B
2013-01-01
Morgellons disease is an emerging skin disease characterized by formation of dermal filaments associated with multisystemic symptoms and tick-borne illness. Some clinicians hypothesize that these often colorful dermal filaments are textile fibers, either self-implanted by patients or accidentally adhering to lesions, and conclude that patients with this disease have delusions of infestation. We present histological observations and electron microscopic imaging from representative Morgellons disease samples revealing that dermal filaments in these cases are keratin and collagen in composition and result from proliferation and activation of keratinocytes and fibroblasts in the epidermis. Spirochetes were detected in the dermatological specimens from our study patients, providing evidence that Morgellons disease is associated with an infectious process.
Characterization and evolution of dermal filaments from patients with Morgellons disease
Middelveen, Marianne J; Mayne, Peter J; Kahn, Douglas G; Stricker, Raphael B
2013-01-01
Morgellons disease is an emerging skin disease characterized by formation of dermal filaments associated with multisystemic symptoms and tick-borne illness. Some clinicians hypothesize that these often colorful dermal filaments are textile fibers, either self-implanted by patients or accidentally adhering to lesions, and conclude that patients with this disease have delusions of infestation. We present histological observations and electron microscopic imaging from representative Morgellons disease samples revealing that dermal filaments in these cases are keratin and collagen in composition and result from proliferation and activation of keratinocytes and fibroblasts in the epidermis. Spirochetes were detected in the dermatological specimens from our study patients, providing evidence that Morgellons disease is associated with an infectious process. PMID:23326202
Intraoral Morgellons disease or delusional parasitosis: a first case report.
Dovigi, Allan J
2010-08-01
Morgellons disease is a new emerging disease that is still controversial and believed to be, by some practitioners, as nothing more than delusional parasitosis. The Center for Disease Control has recently launched an epidemiological investigation into this disease due to the increased number of reports. A first case is reported of an oral lesion and symptoms consistent with Morgellons disease. The nature of the characteristic fibers associated with the intraoral lesion is investigated. Research has started at a number of institutions to elucidate the nature of this emerging disease.
An oral ulceration associated with Morgellons disease: a case report.
Grosskopf, Courtney; Desai, Bhavik; Stoopler, Eric T
2011-08-01
Morgellons disease is a psycho-dermatologic condition in which patients report fibers or filaments "growing" out of their skin. This case report highlights an oral ulceration in a young woman associated with Morgellons disease, a condition that has not been previously described in the dental literature. An increasing number of individuals are self-reporting this condition and oral health care providers must be familiar with this disorder. Copyright © 2011 Mosby, Inc. All rights reserved.
History of Morgellons disease: the same name for different psychodermatologic diseases?
Ferreira, Bárbara Roque; Roccia, Maria Grazia; Cardoso, José Carlos; França, Katlein; Wollina, Uwe; Lotti, Torello; Fioranelli, Massimo
2017-10-01
"Morgellons disease" has been a controversial topic in the history of psychodermatology. The most consensual scientific opinion is that it is a primary psychiatric disorder, particularly, a delusional disorder, although others were also pointed out. Some authors have suggested that it may correspond to a common dermatosis with secondary psychopathology. The Morgellons Research Foundation has advocated that it is "an emerging infectious" entity. This paper intends to critically review the main ideas and controversies, since its first description.
Morgellons Disease: Managing a Mysterious Skin Condition
... 98. Vulink NC. Delusional infestation: State of the art. Acta Dermato-Venereologica. 2016;96(suppl 217):58. ... Original article: http://www.mayoclinic.org/morgellons-disease/ART-20044996 . Mayo Clinic Footer Legal Conditions and Terms ...
Ohn, Jungyoon; Park, Seon Yong; Moon, Jungyoon; Choe, Yun Seon; Kim, Kyu Han
2017-04-01
Morgellons disease is a rare disease with unknown etiology. Herein, we report the first case of Morgellons disease in Korea. A 30-year-old woman presented with a 2-month history of pruritic erythematous patches and erosions on the arms, hands, and chin. She insisted that she had fiber-like materials under her skin, which she had observed through a magnifying device. We performed skin biopsy, and observed a fiber extruding from the dermal side of the specimen. Histopathological examination showed only mild lymphocytic infiltration, and failed to reveal evidence of any microorganism. The polymerase chain reaction for Borrelia burgdorferi was negative in her serum.
Ohn, Jungyoon; Park, Seon Yong; Moon, Jungyoon; Choe, Yun Seon
2017-01-01
Morgellons disease is a rare disease with unknown etiology. Herein, we report the first case of Morgellons disease in Korea. A 30-year-old woman presented with a 2-month history of pruritic erythematous patches and erosions on the arms, hands, and chin. She insisted that she had fiber-like materials under her skin, which she had observed through a magnifying device. We performed skin biopsy, and observed a fiber extruding from the dermal side of the specimen. Histopathological examination showed only mild lymphocytic infiltration, and failed to reveal evidence of any microorganism. The polymerase chain reaction for Borrelia burgdorferi was negative in her serum. PMID:28392653
Harth, Wolfgang; Hermes, Barbara; Freudenmann, Roland W
2010-04-01
Delusional parasitosis (DP) is the most frequent delusional disorder in dermatology. In DP there is a fixed belief of a usually skin-related invasion or infestation by a number of alleged infectious species (usually parasites and bacteria), whose identity has varied over the decades. Since 2002 worldwide an increasing number of patients have complained of unverifiable fibers and filaments in or on the skin, associated with numerous nonspecific complaints (arthralgias, altered cognitive function and extreme fatigue). This entity has been named "Morgellons disease" by the patients themselves, although medical evidence for its existence is lacking. As an example, we discuss a 55-year-old woman who complained of Morgellons disease and was treated as if she had DP. Currently the delusional assumption of infestation with Morgellons should be considered as a new type of DP with some kind of inanimate material. We therefore recommend in case of DP including Morgellons the use of the broader term "delusional infestation".
Morgellons Disease Presenting As an Eyelid Lesion.
Sandhu, Rasanamar K; Steele, Eric A
2016-01-01
Morgellons disease is characterized by complaints of uncomfortable skin sensations and fibers emanating from nonhealing skin lesions. Morgellons disease is well-known in the dermatology and psychiatry literature, where it is typically considered a subtype of delusional parasitosis, but it has not yet been described in the ophthalmology literature. A patient with self-reported Morgellons disease is presented, who was referred for evaluation of left lower eyelid ectropion. She reported that her skin was infested with fibers that were "trying to get down into the eyelid." On examination, she had ectropion of the left lower eyelid, broken cilia, and an ulcerated left upper eyelid lesion concerning for carcinoma. Biopsy of the lesion was consistent with excoriation. Treatment of her ectropion was deferred out of concern for wound dehiscence, given the patient's aggressive excoriation behavior. This case is presented to make the ophthalmologist aware of this disorder and to highlight the appropriate clinical management.
Middelveen, Marianne J; Stricker, Raphael B
2011-01-01
Bovine digital dermatitis is an emerging infectious disease that causes lameness, decreased milk production, and weight loss in livestock. Proliferative stages of bovine digital dermatitis demonstrate keratin filament formation in skin above the hooves in affected animals. The multifactorial etiology of digital dermatitis is not well understood, but spirochetes and other coinfecting microorganisms have been implicated in the pathogenesis of this veterinary illness. Morgellons disease is an emerging human dermopathy characterized by the presence of filamentous fibers of undetermined composition, both in lesions and subdermally. While the etiology of Morgellons disease is unknown, there is serological and clinical evidence linking this phenomenon to Lyme borreliosis and coinfecting tick-borne agents. Although the microscopy of Morgellons filaments has been described in the medical literature, the structure and pathogenesis of these fibers is poorly understood. In contrast, most microscopy of digital dermatitis has focused on associated pathogens and histology rather than the morphology of late-stage filamentous fibers. Clinical, laboratory, and microscopic characteristics of these two diseases are compared. PMID:22253541
Middelveen, Marianne J; Stricker, Raphael B
2011-01-01
Bovine digital dermatitis is an emerging infectious disease that causes lameness, decreased milk production, and weight loss in livestock. Proliferative stages of bovine digital dermatitis demonstrate keratin filament formation in skin above the hooves in affected animals. The multifactorial etiology of digital dermatitis is not well understood, but spirochetes and other coinfecting microorganisms have been implicated in the pathogenesis of this veterinary illness. Morgellons disease is an emerging human dermopathy characterized by the presence of filamentous fibers of undetermined composition, both in lesions and subdermally. While the etiology of Morgellons disease is unknown, there is serological and clinical evidence linking this phenomenon to Lyme borreliosis and coinfecting tick-borne agents. Although the microscopy of Morgellons filaments has been described in the medical literature, the structure and pathogenesis of these fibers is poorly understood. In contrast, most microscopy of digital dermatitis has focused on associated pathogens and histology rather than the morphology of late-stage filamentous fibers. Clinical, laboratory, and microscopic characteristics of these two diseases are compared.
Mortillaro, Gino; Rodgman, Christopher; Kinzie, Erik; Ryals, Sarah
2013-01-01
"Morgellon's Disease" is a term used to describe a bizarre condition characterized by the belief that strange sensations in the skin are due to filaments called "Morgellon's Bodies."' The focus of this case report is to inform readers of the growing incidence of this psychosomatic condition. Unfortunately, self-diagnosis has become increasingly common because of the widespread coverage on the Internet. While the validity of the diagnosis is in question, the impact on patient's lives is real, often debilitating, and bears more examination.
Accordino, Robert E; Engler, Danielle; Ginsburg, Iona H; Koo, John
2008-01-01
Morgellons disease, a pattern of dermatologic symptoms very similar, if not identical, to those of delusions of parasitosis, was first described many centuries ago, but has recently been given much attention on the internet and in the mass media. The present authors present a history of Morgellons disease, in addition to which they discuss the potential benefit of using this diagnostic term as a means of building trust and rapport with patients to maximize treatment benefit. The present authors also suggest "meeting the patient halfway" and creating a therapeutic alliance when providing dermatologic treatment by taking their cutaneous symptoms seriously enough to provide both topical ointments as well as antipsychotic medications, which can be therapeutic in these patients.
Savely, Virginia R; Stricker, Raphael B
2010-05-13
Morgellons disease is a controversial illness in which patients complain of stinging, burning, and biting sensations under the skin. Unusual subcutaneous fibers are the unique objective finding. The etiology of Morgellons disease is unknown, and diagnostic criteria have yet to be established. Our goal was to identify prevalent symptoms in patients with clinically confirmed subcutaneous fibers in order to develop a case definition for Morgellons disease. Patients with subcutaneous fibers observed on physical examination (designated as the fiber group) were evaluated using a data extraction tool that measured clinical and demographic characteristics. The prevalence of symptoms common to the fiber group was then compared with the prevalence of these symptoms in patients with Lyme disease and no complaints of skin fibers. The fiber group consisted of 122 patients. Significant findings in this group were an association with tick-borne diseases and hypothyroidism, high numbers from two states (Texas and California), high prevalence in middle-aged Caucasian women, and an increased prevalence of smoking and substance abuse. Although depression was noted in 29% of the fiber patients, pre-existing delusional disease was not reported. After adjusting for nonspecific symptoms, the most common symptoms reported in the fiber group were: crawling sensations under the skin; spontaneously appearing, slow-healing lesions; hyperpigmented scars when lesions heal; intense pruritus; seed-like objects, black specks, or "fuzz balls" in lesions or on intact skin; fine, thread-like fibers of varying colors in lesions and intact skin; lesions containing thick, tough, translucent fibers that are highly resistant to extraction; and a sensation of something trying to penetrate the skin from the inside out. This study of the largest clinical cohort reported to date provides the basis for an accurate and clinically useful case definition for Morgellons disease.
Savely, Virginia R; Stricker, Raphael B
2010-01-01
Background: Morgellons disease is a controversial illness in which patients complain of stinging, burning, and biting sensations under the skin. Unusual subcutaneous fibers are the unique objective finding. The etiology of Morgellons disease is unknown, and diagnostic criteria have yet to be established. Our goal was to identify prevalent symptoms in patients with clinically confirmed subcutaneous fibers in order to develop a case definition for Morgellons disease. Methods: Patients with subcutaneous fibers observed on physical examination (designated as the fiber group) were evaluated using a data extraction tool that measured clinical and demographic characteristics. The prevalence of symptoms common to the fiber group was then compared with the prevalence of these symptoms in patients with Lyme disease and no complaints of skin fibers. Results: The fiber group consisted of 122 patients. Significant findings in this group were an association with tick-borne diseases and hypothyroidism, high numbers from two states (Texas and California), high prevalence in middle-aged Caucasian women, and an increased prevalence of smoking and substance abuse. Although depression was noted in 29% of the fiber patients, pre-existing delusional disease was not reported. After adjusting for nonspecific symptoms, the most common symptoms reported in the fiber group were: crawling sensations under the skin; spontaneously appearing, slow-healing lesions; hyperpigmented scars when lesions heal; intense pruritus; seed-like objects, black specks, or “fuzz balls” in lesions or on intact skin; fine, thread-like fibers of varying colors in lesions and intact skin; lesions containing thick, tough, translucent fibers that are highly resistant to extraction; and a sensation of something trying to penetrate the skin from the inside out. Conclusions: This study of the largest clinical cohort reported to date provides the basis for an accurate and clinically useful case definition for Morgellons disease. PMID:21437061
The first investigative science-based evidence of Morgellons psychogenesis.
Roncati, Luca; Gatti, Antonietta Morena; Pusiol, Teresa; Piscioli, Francesco; Barbolini, Giuseppe; Maiorana, Antonio
2016-01-01
Morgellons disease is an infrequent syndromic condition, that typically affects middle-aged white women, characterized by crawling sensations on and under the skin, associated with itchy rashes, stinging sores, fiber-like filaments emerging from the sores, severe fatigue, concentrating difficulty, and memory loss. The scientific community is prone to believe that Morgellons is the manifestation of various psychiatric syndromes (Munchausen, Munchausen by proxy, Ekbom, Wittmaack-Ekbom). Up until now, no investigative science-based evidence about its psychogenesis has ever been provided. In order to close this gap, we have analyzed the filaments extracted from the skin lesions of a 49-year-old Caucasian female patient, by using a Field Emission Gun-Environmental Electron Scanning Microscope equipped with an X-ray microprobe, for the chemico-elemental characterization of the filaments, comparing them with those collected during a detailed indoor investigation, with careful air monitoring, in her apartment. Our results prove the self-introduction under the epidermis of environmental filaments. For the first time in the literature, we have scientifically demonstrated the self-induced nature of Morgellons disease, thereby wiping out fanciful theories about its etiopathogenesis.
Information, consent and treatment of patients with Morgellons disease: an ethical perspective.
Söderfeldt, Ylva; Groß, Dominik
2014-04-01
Morgellons is a medically contested diagnosis with foremost dermatological symptoms. Patients experience fibers emerging from the skin, together with a range of other somatic, psychiatric, and neurological complaints. Within the medical community, it is generally held to be a variation of delusional parasitosis/delusional infestation, which is usually treated with antipsychotics. Little attention has been paid in the literature to the ethical aspects of treating patients with Morgellons disease. The communicative strategies suggested in the literature display significant ethical issues, primarily the use of therapeutic privilege, i.e. withholding information from the patient. Since this limits patient autonomy, that approach is ethically problematic. Instead, the physician has an ethical obligation to respect the patient's autonomy, provide full information, and seek consent before initiating a psychiatric referral.
Morgellons disease: a filamentous borrelial dermatitis.
Middelveen, Marianne J; Stricker, Raphael B
2016-01-01
Morgellons disease (MD) is a dermopathy characterized by multicolored filaments that lie under, are embedded in, or project from skin. Although MD was initially considered to be a delusional disorder, recent studies have demonstrated that the dermopathy is associated with tickborne infection, that the filaments are composed of keratin and collagen, and that they result from proliferation of keratinocytes and fibroblasts in epithelial tissue. Culture, histopathological and molecular evidence of spirochetal infection associated with MD has been presented in several published studies using a variety of techniques. Spirochetes genetically identified as Borrelia burgdorferi sensu stricto predominate as the infective agent in most of the Morgellons skin specimens studied so far. Other species of Borrelia including Borrelia garinii , Borrelia miyamotoi , and Borrelia hermsii have also been detected in skin specimens taken from MD patients. The optimal treatment for MD remains to be determined.
Morgellons disease: a filamentous borrelial dermatitis
Middelveen, Marianne J; Stricker, Raphael B
2016-01-01
Morgellons disease (MD) is a dermopathy characterized by multicolored filaments that lie under, are embedded in, or project from skin. Although MD was initially considered to be a delusional disorder, recent studies have demonstrated that the dermopathy is associated with tickborne infection, that the filaments are composed of keratin and collagen, and that they result from proliferation of keratinocytes and fibroblasts in epithelial tissue. Culture, histopathological and molecular evidence of spirochetal infection associated with MD has been presented in several published studies using a variety of techniques. Spirochetes genetically identified as Borrelia burgdorferi sensu stricto predominate as the infective agent in most of the Morgellons skin specimens studied so far. Other species of Borrelia including Borrelia garinii, Borrelia miyamotoi, and Borrelia hermsii have also been detected in skin specimens taken from MD patients. The optimal treatment for MD remains to be determined. PMID:27789971
Morgellons: contested illness, diagnostic compromise and medicalisation.
Fair, Brian
2010-05-01
The case of Morgellons illustrates how the emergence of a new medically contested illness intersected with and impacted on the diagnostic processes of an existing uncontested psychiatric condition, Delusional Parasitosis (DP). More specifically, the sociopolitical processes at play in the contested illness, Morgellons, dubiously reflect patient empowerment, as well the resilience and power of medical jurisdiction. This research offers insights into the contested illness and medicalisation literatures, and aims to bridge these two approaches towards the relationship between patient empowerment and medical authority, which I do through the notion of doctor-patient compromise. The data for this research come from a comprehensive qualitative analysis of Morgellons discourse through four key sources: the pro-Morgellons website Morgellons.org; the anti-Morgellons website Morgellonswatch.com; the popular media's portrayal of Morgellons; and the DP and Morgellons articles published in peer-reviewed medical journals, as made available on PubMed.
Morgellons disease and delusions of parasitosis.
Robles, David T; Olson, Jonathan M; Combs, Heidi; Romm, Sharon; Kirby, Phil
2011-02-01
Morgellons disease is a controversial and poorly defined symptom cluster of skin lesions and somatic symptoms, most notably 'fibers' in the skin. Because of widespread coverage in the media and on the Internet, there are an increasing number of patients presenting to dermatologists. We present three patients who believed that they had fibers in their skin. We offer a discussion of delusions of parasitosis to demonstrate similarities between these conditions. It has been suggested by a limited number of healthcare providers that an unknown infectious agent underlies this symptom complex yet no available evidence supports this assertion. Laboratory values that would be reflective of an infectious process (e.g. elevated white blood cells, sedimentation rate, C reactive protein) are routinely normal and biopsies often reflect only nonspecific findings such as acute and chronic inflammation with erosion or ulceration. Patients with Morgellons disease generally lack insight into their disease and reject the need for psychiatric help. The goal is to build trust and refrain from minimizing what the patient experiences. Attentive examination of the patient's skin and fragments they present is necessary to rule out a true underlying pathologic process and to establish a trusting relationship. A supportive, non-confrontational approach is ideal. The patient is best treated by a team of practitioners of several specialties, including dermatologists, psychiatrists, and counselors.
Association of spirochetal infection with Morgellons disease.
Middelveen, Marianne J; Burugu, Divya; Poruri, Akhila; Burke, Jennie; Mayne, Peter J; Sapi, Eva; Kahn, Douglas G; Stricker, Raphael B
2013-01-01
Morgellons disease (MD) is an emerging multisystem illness characterized by skin lesions with unusual filaments embedded in or projecting from epithelial tissue. Filament formation results from abnormal keratin and collagen expression by epithelial-based keratinocytes and fibroblasts. Recent research comparing MD to bovine digital dermatitis, an animal infectious disease with similar skin features, provided clues that spirochetal infection could play an important role in the human disease as it does in the animal illness. Based on histological staining, immunofluorescent staining, electron microscopic imaging and polymerase chain reaction, we report the detection of Borrelia spirochetes in dermatological tissue of four randomly-selected MD patients. The association of MD with spirochetal infection provides evidence that this infection may be a significant factor in the illness and refutes claims that MD lesions are self-inflicted and that people suffering from this disorder are delusional. Molecular characterization of the Borrelia spirochetes found in MD patients is warranted.
Association of spirochetal infection with Morgellons disease
Stricker, Raphael B
2013-01-01
Morgellons disease (MD) is an emerging multisystem illness characterized by skin lesions with unusual filaments embedded in or projecting from epithelial tissue. Filament formation results from abnormal keratin and collagen expression by epithelial-based keratinocytes and fibroblasts. Recent research comparing MD to bovine digital dermatitis, an animal infectious disease with similar skin features, provided clues that spirochetal infection could play an important role in the human disease as it does in the animal illness. Based on histological staining, immunofluorescent staining, electron microscopic imaging and polymerase chain reaction, we report the detection of Borrelia spirochetes in dermatological tissue of four randomly-selected MD patients. The association of MD with spirochetal infection provides evidence that this infection may be a significant factor in the illness and refutes claims that MD lesions are self-inflicted and that people suffering from this disorder are delusional. Molecular characterization of the Borrelia spirochetes found in MD patients is warranted. PMID:24715950
Middelveen, Marianne J; Bandoski, Cheryl; Burke, Jennie; Sapi, Eva; Filush, Katherine R; Wang, Yean; Franco, Agustin; Mayne, Peter J; Stricker, Raphael B
2015-02-12
Morgellons disease (MD) is a complex skin disorder characterized by ulcerating lesions that have protruding or embedded filaments. Many clinicians refer to this condition as delusional parasitosis or delusional infestation and consider the filaments to be introduced textile fibers. In contrast, recent studies indicate that MD is a true somatic illness associated with tickborne infection, that the filaments are keratin and collagen in composition and that they result from proliferation and activation of keratinocytes and fibroblasts in the skin. Previously, spirochetes have been detected in the dermatological specimens from four MD patients, thus providing evidence of an infectious process. Based on culture, histology, immunohistochemistry, electron microscopy and molecular testing, we present corroborating evidence of spirochetal infection in a larger group of 25 MD patients. Irrespective of Lyme serological reactivity, all patients in our study group demonstrated histological evidence of epithelial spirochetal infection. Strength of evidence based on other testing varied among patients. Spirochetes identified as Borrelia strains by polymerase chain reaction (PCR) and/or in-situ DNA hybridization were detected in 24/25 of our study patients. Skin cultures containing Borrelia spirochetes were obtained from four patients, thus demonstrating that the organisms present in dermatological specimens were viable. Spirochetes identified by PCR as Borrelia burgdorferi were cultured from blood in seven patients and from vaginal secretions in three patients, demonstrating systemic infection. Based on these observations, a clinical classification system for MD is proposed. Our study using multiple detection methods confirms that MD is a true somatic illness associated with Borrelia spirochetes that cause Lyme disease. Further studies are needed to determine the optimal treatment for this spirochete-associated dermopathy.
Mohandas, Padma; Bewley, Anthony; Taylor, Ruth
2018-03-01
In recent years, there has been a reported increase in affliction of the skin with small fibres or other particles. The condition has been referred to as Morgellons disease. Patients present with stinging, burning or crawling sensations of the skin, with perceived extrusion of inanimate material alongside fatigue and other systemic symptoms. Sufferers often experience significant morbidity and reduction in quality of life. We aimed to explore the various clinical presentations, management strategies and outcomes employed to treat this condition in our patients. We conducted a retrospective case notes review of 35 patients referred to our multidisciplinary psycho-dermatology clinic at the Royal London Hospital between January 2004 and January 2017. The majority of patients were women (25) 71.4%, with a mean age of 54.6 years (26-80 years). Most (26) 74.2% were living alone. The average duration of illness prior to presentation was 3.8 years (4 months-20 years). Many patients had perceived precipitating factors (54.2%) and often self-diagnosed (28.5%). Psychiatric co-morbidities included 42.8% with depressive symptoms and 25.7% with anxiety. Substance misuse was elicited in five patients (14%). Management of patients included both the treatment of skin disease and psychosocial co-morbidities. Out of the 35 patients who attended (14) 40% cleared or showed significant improvement. Sixteen (45.7%) patients were stable and under review. One patient declined treatment and three did not attend review. One patient died from disease unrelated to her skin condition. Morgellons disease is a condition, which is widely discussed on the internet and patients often self-diagnose. The course of the disease can be chronic and debilitating. For a positive outcome, it is important that a strong physican-patient relationship is cultivated. As demonstrated in this case series, managing patients holistically in an integrated multidisciplinary dermatology setting helps achieve positive outcomes.
History of Morgellons disease: from delusion to definition
Middelveen, Marianne J; Fesler, Melissa C
2018-01-01
Morgellons disease (MD) is a skin condition characterized by the presence of multicolored filaments that lie under, are embedded in, or project from skin. Although the condition may have a longer history, disease matching the above description was first reported in the US in 2002. Since that time, the condition that we know as MD has become a polemic topic. Because individuals afflicted with the disease may have crawling or stinging sensations and sometimes believe they have an insect or parasite infestation, most medical practitioners consider MD a purely delusional disorder. Clinical studies supporting the hypothesis that MD is exclusively delusional in origin have considerable methodological flaws and often neglect the fact that mental disorders can result from underlying somatic illness. In contrast, rigorous experimental investigations show that this skin affliction results from a physiological response to the presence of an infectious agent. Recent studies from that point of view show an association between MD and spirochetal infection in humans, cattle, and dogs. These investigations have determined that the cutaneous filaments are not implanted textile fibers, but are composed of the cellular proteins keratin and collagen and result from overproduction of these filaments in response to spirochetal infection. Further studies of the genetics, pathogenesis, and treatment of MD are warranted. PMID:29467580
History of Morgellons disease: from delusion to definition.
Middelveen, Marianne J; Fesler, Melissa C; Stricker, Raphael B
2018-01-01
Morgellons disease (MD) is a skin condition characterized by the presence of multicolored filaments that lie under, are embedded in, or project from skin. Although the condition may have a longer history, disease matching the above description was first reported in the US in 2002. Since that time, the condition that we know as MD has become a polemic topic. Because individuals afflicted with the disease may have crawling or stinging sensations and sometimes believe they have an insect or parasite infestation, most medical practitioners consider MD a purely delusional disorder. Clinical studies supporting the hypothesis that MD is exclusively delusional in origin have considerable methodological flaws and often neglect the fact that mental disorders can result from underlying somatic illness. In contrast, rigorous experimental investigations show that this skin affliction results from a physiological response to the presence of an infectious agent. Recent studies from that point of view show an association between MD and spirochetal infection in humans, cattle, and dogs. These investigations have determined that the cutaneous filaments are not implanted textile fibers, but are composed of the cellular proteins keratin and collagen and result from overproduction of these filaments in response to spirochetal infection. Further studies of the genetics, pathogenesis, and treatment of MD are warranted.
Clinical evaluation of Morgellons disease in a cohort of North American patients
Fesler, Melissa C.; Middelveen, Marianne J.; Stricker, Raphael B.
2018-01-01
Morgellons disease (MD) is a dermatological condition characterized by aberrant production of keratin and collagen fibers in skin. Although infection with Borrelia burgdorferi, the causative agent of Lyme disease (LD), has been associated with MD, relatively few studies have hitherto provided epidemiological evidence regarding this association. A cohort of 1000 seropositive North American LD patients was evaluated for the presence of MD. Patients were diagnosed with MD based on detection of microscopic fibers in skin lesions or under unbroken skin. Demographic and clinical features of MD patients were analyzed, and laboratory testing for tickborne coinfections and other infectious agents, was performed. Subjective and objective features of MD were analyzed using statistical methods. Of 1000 seropositive LD patients, 60 (6%) were diagnosed with MD. Of these 60 patients, 75% were female and 78% presented in the late disseminated stage of MD. All 60 patients (100%) were seropositive for B. burgdorferi infection. Tickborne coinfections in these patients included Babesia spp (62%), Bartonella and Rickettsia (25% each), Ehrlichia (15%) and Anaplasma (10%). Helicobacter pylori was detected in 12% of MD patients. In all, 77% of MD patients had one or more coinfections. This study confirms recent findings that MD occurs in a limited subset of LD patients. The clinical and genetic determinants of MD in LD patients require further study. PMID:29774138
Clinical evaluation of Morgellons disease in a cohort of North American patients.
Fesler, Melissa C; Middelveen, Marianne J; Stricker, Raphael B
2018-04-23
Morgellons disease (MD) is a dermatological condition characterized by aberrant production of keratin and collagen fibers in skin. Although infection with Borrelia burgdorferi , the causative agent of Lyme disease (LD), has been associated with MD, relatively few studies have hitherto provided epidemiological evidence regarding this association. A cohort of 1000 seropositive North American LD patients was evaluated for the presence of MD. Patients were diagnosed with MD based on detection of microscopic fibers in skin lesions or under unbroken skin. Demographic and clinical features of MD patients were analyzed, and laboratory testing for tickborne coinfections and other infectious agents, was performed. Subjective and objective features of MD were analyzed using statistical methods. Of 1000 seropositive LD patients, 60 (6%) were diagnosed with MD. Of these 60 patients, 75% were female and 78% presented in the late disseminated stage of MD. All 60 patients (100%) were seropositive for B. burgdorferi infection. Tickborne coinfections in these patients included Babesia spp (62%), Bartonella and Rickettsia (25% each), Ehrlichia (15%) and Anaplasma (10%). Helicobacter pylori was detected in 12% of MD patients. In all, 77% of MD patients had one or more coinfections. This study confirms recent findings that MD occurs in a limited subset of LD patients. The clinical and genetic determinants of MD in LD patients require further study.
Psychosomatic factors in pruritus
Tey, Hong Liang; Wallengren, Joanna; Yosipovitch, Gil
2013-01-01
Pruritus and psyche are intricately and reciprocally related, with psychophysiological evidence and psychopathological explanations helping us to understand their complex association. Their interaction may be conceptualized and classified into 3 groups: pruritic diseases with psychiatric sequelae, pruritic diseases aggravated by psychosocial factors, and psychiatric disorders causing pruritus. Management of chronic pruritus is directed at treating the underlying causes and adopting a multidisciplinary approach to address the dermatologic, somatosensory, cognitive, and emotional aspects. Pharmcotherapeutic agents that are useful for chronic pruritus with comorbid depression and/or anxiety comprise selective serotonin reuptake inhibitors, mirtazapine, tricyclic antidepressants (amitriptyline and doxepin), and anticonvulsants (gabapentin, pregabalin); the role of neurokinin receptor-1 antagonists awaits verification. Antipsychotics are required for treating itch and formication associated with schizophrenia and delusion of parasitosis (including Morgellons disease). PMID:23245971
New findings in delusions of parasitosis.
Fellner, Michael J
2012-01-01
Two new cases are presented with delusions of parasitosis. Both were women, one middle-aged and one elderly, and exhibited classic symptoms of parasites and "strings" in the skin indicative of Morgellons disease. Each had an additional psychiatric disorder: drug addiction to cocaine and senile dementia. They also illustrate the difficulty encountered by the dermatologist in providing adequate therapy because of resistance to psychiatric referral as well as to standard accepted medication. Newer psychotropics, such as risperdal and lexapro, show promise in helping these patients and add to the therapeutic armamentarium of pimozide.
Psychosomatic factors in pruritus.
Tey, Hong Liang; Wallengren, Joanna; Yosipovitch, Gil
2013-01-01
Pruritus and psyche are intricately and reciprocally related, with psychophysiological evidence and psychopathological explanations helping us to understand their complex association. Their interaction may be conceptualized and classified into 3 groups: pruritic diseases with psychiatric sequelae, pruritic diseases aggravated by psychosocial factors, and psychiatric disorders causing pruritus. Management of chronic pruritus is directed at treating the underlying causes and adopting a multidisciplinary approach to address the dermatologic, somatosensory, cognitive, and emotional aspects. Pharmcotherapeutic agents that are useful for chronic pruritus with comorbid depression and/or anxiety comprise selective serotonin reuptake inhibitors, mirtazapine, tricyclic antidepressants (amitriptyline and doxepin), and anticonvulsants (gabapentin, pregabalin); the role of neurokinin receptor-1 antagonists awaits verification. Antipsychotics are required for treating itch and formication associated with schizophrenia and delusion of parasitosis (including Morgellons disease). Copyright © 2013 Elsevier Inc. All rights reserved.
Delusional infestation with unusual pathogens: a report of three cases.
Dewan, P; Miller, J; Musters, C; Taylor, R E; Bewley, A P
2011-10-01
Delusional infestation (DI) is a psychiatric disorder characterized by a fixed, false belief that the patient is infested with extracorporeal agents. It is known by several names, including the more commonly used term 'delusional parasitosis'. The psychiatric disease is responsible for the cutaneous pathology. About 90% of patients with DI seek help from dermatologists, and most reject psychiatric referral. Thus, effective management requires incorporation of psychiatric principles. We report three cases of DI with inanimate materials, and examine 'Morgellons' disease. We believe that patients with unusual presentations of DI are likely to be seen more commonly in the future. These patients appear to be a subgroup of DI, and may be even more difficult to treat than other patients with DI. © The Author(s). CED © 2011 British Association of Dermatologists.
Krooks, J A; Weatherall, A G; Holland, P J
2018-06-01
Approximately half of all patients presenting to dermatologists exhibit signs and symptoms of psychiatric conditions that are either primary or secondary to cutaneous disease. Because patients typically resist psychiatric consult, dermatologists often are on the front line in evaluating and treating these patients. Accordingly, distinguishing the specific underlying or resulting psychiatric condition is essential for effective treatment. The etiology, epidemiology, clinical presentation, diagnosis, and first-line treatment of specific primary psychiatric causes of dermatologic conditions, including delusional infestation, Morgellons syndrome, olfactory reference syndrome, body dysmorphic disorder, excoriation disorder, trichotillomania, and dermatitis artefacta are discussed here, followed by a discussion of the recommended treatment approach with an overview of the different first-line therapies discussed in this review, specifically cognitive behavioral therapy, atypical antipsychotics, selective serotonin reuptake inhibitors, and tricyclic antidepressants. Included is a guide for dermatologists to use while prescribing these medications.
Treatment of Oral Mucosal Lesions Associated With Overlapping Psychodermatologic Disorders.
Alfaris, Sausan; France, Katherine; Sollecito, Thomas P; Stoopler, Eric T
2018-04-01
Delusional infestations are psychodermatologic disorders in which those affected have a false belief they are infested by parasites and/or "growing" inanimate objects from cutaneous surfaces. Individuals with delusional parasitosis (DP) believe parasites, bacteria, worms, mites, or other living organisms are the source of cutaneous symptoms, while those with Morgellons disease (MD) attribute their symptoms to growth of small fibers or inorganic material. In both DP and MD, self-inflicted, non-healing cutaneous lesions caused by scratching at the affected areas to alleviate symptoms are commonly observed. This report describes a case of oral mucosal lesions in a patient demonstrating overlapping symptoms of DP and MD. It is important for oral healthcare providers to recognize oral signs and symptoms that may be associated with psychodermatologic disorders.
Delusional disorders in dermatology: a brief review.
Robles, David T; Romm, Sharon; Combs, Heidi; Olson, Jonathan; Kirby, Phil
2008-06-15
There are several unique psychiatric disorders that are likely to present to a dermatologist because of their accompanying skin complaints. Delusions of parasitosis (DP) is a fixed, false belief of parasitic infestation that may lead patients to compulsively self-mutilate while attempting to remove the non-existent parasites. Morgellons disease is a controversial condition characterized by a fixed belief that fibers that are imbedded or extruding from the skin; this condition is likely in the spectrum of DP. Body dysmorphic disorder (BDD) is a preoccupation with an imagined defect in appearance that causes significant distress and is associated with time consuming rituals, isolation, depression, and increased risk of suicide. Olfactory reference syndrome (ORS) is a preoccupation with body odor leading to the stigmata of shame, embarrassment, and social isolation. This brief review examines each of these conditions and their management because any one of them may present to a dermatologist.
Reduced-illuminance autofluorescence imaging in ABCA4-associated retinal degenerations
NASA Astrophysics Data System (ADS)
Cideciyan, Artur V.; Swider, Malgorzata; Aleman, Tomas S.; Roman, Marisa I.; Sumaroka, Alexander; Schwartz, Sharon B.; Stone, Edwin M.; Jacobson, Samuel G.
2007-05-01
The health of the retinal pigment epithelium (RPE) can be estimated with autofluorescence (AF) imaging of lipofuscin, which accumulates as a byproduct of retinal exposure to light. Lipofuscin may be toxic to the RPE, and its toxicity may be enhanced by short-wavelength (SW) illumination. The high-intensity and SW excitation light used in conventional AF imaging could, at least in principle, increase the rate of lipofuscin accumulation and/or increase its toxicity. We considered two reduced-illuminance AF imaging (RAFI) methods as alternatives to conventional AF imaging. RAFI methods use either near-infrared (NIR) light or reduced-radiance SW illumination for excitation of fluorophores. We quantified the distribution of RAFI signals in relation to retinal structure and function in patients with the prototypical lipofuscin accumulation disease caused by mutations in ABCA4. There was evidence for two subclinical stages of macular ABCA4 disease involving hyperautofluorescence of both SW- and NIR-RAFI with and without associated loss of visual function. Use of RAFI methods and microperimetry in future clinical trials involving lipofuscinopathies should allow quantification of subclinical disease expression and progression without subjecting the diseased retina/RPE to undue light exposure.
... BDSRA Store BDSRA Membership About BDSRA Chapter Locator Financials and Reporting History and Mission Illuminator Newsletter Our Staff and ... BDSRA Membership About BDSRA About BDSRA Chapter Locator Financials and Reporting History and Mission Illuminator Newsletter Our Staff and ...
NASA Astrophysics Data System (ADS)
Adal, Kedir M.; van Etten, Peter G.; Martinez, Jose P.; Rouwen, Kenneth; Vermeer, Koenraad A.; van Vliet, Lucas J.
2017-03-01
Automated detection and quantification of spatio-temporal retinal changes is an important step to objectively assess disease progression and treatment effects for dynamic retinal diseases such as diabetic retinopathy (DR). However, detecting retinal changes caused by early DR lesions such as microaneurysms and dot hemorrhages from longitudinal pairs of fundus images is challenging due to intra and inter-image illumination variation between fundus images. This paper explores a method for automated detection of retinal changes from illumination normalized fundus images using a deep convolutional neural network (CNN), and compares its performance with two other CNNs trained separately on color and green channel fundus images. Illumination variation was addressed by correcting for the variability in the luminosity and contrast estimated from a large scale retinal regions. The CNN models were trained and evaluated on image patches extracted from a registered fundus image set collected from 51 diabetic eyes that were screened at two different time-points. The results show that using normalized images yield better performance than color and green channel images, suggesting that illumination normalization greatly facilitates CNNs to quickly and correctly learn distinctive local image features of DR related retinal changes.
Spectrally optimal illuminations for diabetic retinopathy detection in retinal imaging
NASA Astrophysics Data System (ADS)
Bartczak, Piotr; Fält, Pauli; Penttinen, Niko; Ylitepsa, Pasi; Laaksonen, Lauri; Lensu, Lasse; Hauta-Kasari, Markku; Uusitalo, Hannu
2017-04-01
Retinal photography is a standard method for recording retinal diseases for subsequent analysis and diagnosis. However, the currently used white light or red-free retinal imaging does not necessarily provide the best possible visibility of different types of retinal lesions, important when developing diagnostic tools for handheld devices, such as smartphones. Using specifically designed illumination, the visibility and contrast of retinal lesions could be improved. In this study, spectrally optimal illuminations for diabetic retinopathy lesion visualization are implemented using a spectrally tunable light source based on digital micromirror device. The applicability of this method was tested in vivo by taking retinal monochrome images from the eyes of five diabetic volunteers and two non-diabetic control subjects. For comparison to existing methods, we evaluated the contrast of retinal images taken with our method and red-free illumination. The preliminary results show that the use of optimal illuminations improved the contrast of diabetic lesions in retinal images by 30-70%, compared to the traditional red-free illumination imaging.
Quantitative phase imaging of retinal cells (Conference Presentation)
NASA Astrophysics Data System (ADS)
LaForest, Timothé; Carpentras, Dino; Kowalczuk, Laura; Behar-Cohen, Francine; Moser, Christophe
2017-02-01
Vision process is ruled by several cells layers of the retina. Before reaching the photoreceptors, light entering the eye has to pass through a few hundreds of micrometers thick layer of ganglion and neurons cells. Macular degeneration is a non-curable disease of themacula occurring with age. This disease can be diagnosed at an early stage by imaging neuronal cells in the retina and observing their death chronically. These cells are phase objects locatedon a background that presents an absorption pattern and so difficult to see with standard imagingtechniques in vivo. Phase imaging methods usually need the illumination system to be on the opposite side of the sample with respect to theimaging system. This is a constraintand a challenge for phase imaging in-vivo. Recently, the possibility of performing phase contrast imaging from one side using properties of scattering media has been shown. This phase contrast imaging is based on the back illumination generated by the sample itself. Here, we present a reflection phase imaging technique based on oblique back-illumination. The oblique back-illumination creates a dark field image of the sample. Generating asymmetric oblique illumination allows obtaining differential phase contrast image, which in turn can be processed to recover a quantitative phase image. In the case of the eye, a transcleral illumination can generate oblique incident light on the retina and the choroidal layer.The back reflected light is then collected by the eye lens to produce dark field image. We show experimental results of retinal phase imagesin ex vivo samples of human and pig retina.
Freudenmann, Roland W; Lepping, Peter
2009-10-01
This papers aims at familiarizing psychiatric and nonpsychiatric readers with delusional infestation (DI), also known as delusional parasitosis. It is characterized by the fixed belief of being infested with pathogens against all medical evidence. DI is no single disorder but can occur as a delusional disorder of the somatic type (primary DI) or secondary to numerous other conditions. A set of minimal diagnostic criteria and a classification are provided. Patients with DI pose a truly interdisciplinary problem to the medical system. They avoid psychiatrists and consult dermatologists, microbiologists, or general practitioners but often lose faith in professional medicine. Epidemiology and history suggest that the imaginary pathogens change constantly, while the delusional theme "infestation" is stable and ubiquitous. Patients with self-diagnosed "Morgellons disease" can be seen as a variation of this delusional theme. For clinicians, clinical pathways for efficient diagnostics and etiology-specific treatment are provided. Specialized outpatient clinics in dermatology with a liaison psychiatrist are theoretically best placed to provide care. The most intricate problem is to engage patients in psychiatric therapy. In primary DI, antipsychotics are the treatment of choice, according to limited but sufficient evidence. Pimozide is no longer the treatment of choice for reasons of drug safety. Future research should focus on pathophysiology and the neural basis of DI, as well as on conclusive clinical trials, which are widely lacking. Innovative approaches will be needed, since otherwise patients are unlikely to adhere to any study protocol.
Kim, Min-Jeong; Tang, Chee Hwa; Bang, Woo Suk; Yuk, Hyun-Gyun
2017-03-06
To investigate a potential of 405±5nm light emitting diode (LED) as a novel technology for food preservation, the antibacterial effect of 405±5nm LED on Escherichia coli O157:H7, Listeria monocytogenes, and Salmonella spp. on the surface of fresh-cut mango and its influence on fruit quality were evaluated at different storage temperatures. LED-illumination inactivated 1.0-1.6 logCFU/cm 2 of populations at 4 and 10°C for 36-48h (total dose, 2.6-3.5kJ/cm 2 ) regardless of bacterial species, while those on non-illuminated mange remained unchanged or slightly increased during storage. At 20°C for 24h (total dose, 1.7kJ/cm 2 ), non-illuminated E. coli O157:H7 and Salmonella gradually grew, whereas LED-illumination reduced 1.2 log of Salmonella and inhibited the growth of E. coli O157:H7. Unlike these, non-illuminated L. monocytogenes cells rapidly increased to 7.3 log, while illuminated cells reached 4.6 log, revealing that LED-illumination delayed their growth. There were no significant (P>0.05) differences in color, antioxidant capacity, ascorbic acid, β-carotene, and flavonoid between non-illuminated and illuminated cut mangoes, regardless of storage temperature. These results suggest that 405±5nm LEDs in combination with chilling temperatures could be applied to preserve fresh-cut fruits without deterioration of physicochemical quality of fruits at food establishments, minimizing the risk of foodborne disease. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Li, Hao; Liu, Wenzhong; Zhang, Hao F.
2015-10-01
Rodent models are indispensable in studying various retinal diseases. Noninvasive, high-resolution retinal imaging of rodent models is highly desired for longitudinally investigating the pathogenesis and therapeutic strategies. However, due to severe aberrations, the retinal image quality in rodents can be much worse than that in humans. We numerically and experimentally investigated the influence of chromatic aberration and optical illumination bandwidth on retinal imaging. We confirmed that the rat retinal image quality decreased with increasing illumination bandwidth. We achieved the retinal image resolution of 10 μm using a 19 nm illumination bandwidth centered at 580 nm in a home-built fundus camera. Furthermore, we observed higher chromatic aberration in albino rat eyes than in pigmented rat eyes. This study provides a design guide for high-resolution fundus camera for rodents. Our method is also beneficial to dispersion compensation in multiwavelength retinal imaging applications.
Introduction to Protein Structure through Genetic Diseases
ERIC Educational Resources Information Center
Schneider, Tanya L.; Linton, Brian R.
2008-01-01
An illuminating way to learn about protein function is to explore high-resolution protein structures. Analysis of the proteins involved in genetic diseases has been used to introduce students to protein structure and the role that individual mutations can play in the onset of disease. Known mutations can be correlated to changes in protein…
NASA Astrophysics Data System (ADS)
Mang, Ou-Yang; Ko, Mei Lan; Tsai, Yi-Chun; Chiou, Jin-Chern; Huang, Ting-Wei
2016-03-01
The pupil response to light can reflect various kinds of diseases which are related to physiological health. Pupillary abnormalities may be influenced on people by autonomic neuropathy, glaucoma, diabetes, genetic diseases, and high myopia. In the early stage of neuropathy, it is often asymptomatic and difficulty detectable by ophthalmologists. In addition, the position of injured nerve can lead to unsynchronized pupil response for human eyes. In our study, we design the pupilometer to measure the binocular pupil response simultaneously. It uses the different wavelength of LEDs such as white, red, green and blue light to stimulate the pupil and record the process. Therefore, the pupilometer mainly contains two systems. One is the image acquisition system, it use the two cameras modules with the same external triggered signal to capture the images of the pupil simultaneously. The other one is the illumination system. It use the boost converter ICs and LED driver ICs to supply the constant current for LED to maintain the consistent luminance in each experiments for reduced experimental error. Furthermore, the four infrared LEDs are arranged nearby the stimulating LEDs to illuminate eyes and increase contrast of image for image processing. In our design, we success to implement the function of synchronized image acquisition with the sample speed in 30 fps and the stable illumination system for precise measurement of experiment.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Institute for Occupational Safety and Health, Center for Disease Control, Public Health Service, Department... section. Examples of physical agents are noise, temperature, illumination, vibration, radiation, and...
Hylwa, Sara A; Foster, Ashley A; Bury, Jessica E; Davis, Mark D P; Pittelkow, Mark R; Bostwick, J Michael
2012-01-01
Delusional infestation, which encompasses both delusions of parasitosis and delusions of infestation with inanimate objects (sometimes called Morgellons disease), has been said to represent a distinct and encapsulated delusion, that is, a stand-alone diagnosis. Anecdotally, we have observed that patients with delusional infestation often have one or more psychiatric comorbid conditions and that delusional infestation should not be regarded as a stand-alone diagnosis. The purpose of this study was to identify whether patients with delusional infestation have psychiatric comorbid conditions. We therefore identified patients who had been formally evaluated in the Department of Psychiatry during their visit to Mayo Clinic. We retrospectively searched for and reviewed the cases of all patients with delusional infestation seen from 2001 through 2007 at Mayo Clinic, Rochester, Minnesota, and who underwent psychiatric evaluation. The diagnoses resulting from psychiatric evaluation were analyzed. During the 7-year study period, 109 patients seen for delusional infestation at Mayo Clinic were referred to the Department of Psychiatry, 54 (50%) of whom actually followed through with psychiatric consultation. Of these 54 patients, 40 (74%) received additional active psychiatric diagnoses; 14 patients (26%) had delusional infestation alone. Abnormal personality traits were rarely documented. Most patients with delusional infestation have multiple coexisting or underlying psychiatric disorders. Therefore, evaluation by a psychiatrist, when possible, is advised for all patients with delusional infestation. Copyright © 2012 The Academy of Psychosomatic Medicine. Published by Elsevier Inc. All rights reserved.
Beck, W; Gobatto, C
2016-03-01
Nocturnal rodents should be assessed at an appropriate time of day, which leads to a challenge in identifying an adequate environmental light which allows animal visualisation without perturbing physiological homeostasis. Thus, we analysed the influence of high wavelength and low intensity light during dark period on physical exercise and biochemical and haematological parameters of nocturnal rats. We submitted 80 animals to an exhaustive exercise at individualised intensity under two different illuminations during dark period. Red light (> 600 nm; < 15lux) was applied constantly during dark period (EI; for experimental illumination groups) or only for handling and assessments (SI; for standard illumination groups). EI led to worse haematological and biochemical conditions, demonstrating that EI alone can influence physiological parameters and jeopardise result interpretation. SI promotes normal physiological conditions and greater aerobic tolerance than EI, showing the importance of a correct illumination pattern for all researchers that employ nocturnal rats for health/disease or sports performance experiments.
Small angle x-ray scattering with edge-illumination
NASA Astrophysics Data System (ADS)
Modregger, Peter; Cremona, Tiziana P.; Benarafa, Charaf; Schittny, Johannes C.; Olivo, Alessandro; Endrizzi, Marco
2016-08-01
Sensitivity to sub-pixel sample features has been demonstrated as a valuable capability of phase contrast x-ray imaging. Here, we report on a method to obtain angular-resolved small angle x-ray scattering distributions with edge-illumination- based imaging utilizing incoherent illumination from an x-ray tube. Our approach provides both the three established image modalities (absorption, differential phase and scatter strength), plus a number of additional contrasts related to unresolved sample features. The complementarity of these contrasts is experimentally validated by using different materials in powder form. As a significant application example we show that the extended complementary contrasts could allow the diagnosis of pulmonary emphysema in a murine model. In support of this, we demonstrate that the properties of the retrieved scattering distributions are consistent with the expectation of increased feature sizes related to pulmonary emphysema. Combined with the simplicity of implementation of edge-illumination, these findings suggest a high potential for exploiting extended sub-pixel contrasts in the diagnosis of lung diseases and beyond.
Using a metagenomic approach to improve our understanding of Armillaria root disease
Amy Ross-Davis; Matt Settles; John W. Hanna; John D. Shaw; Andrew T. Hudak; Deborah S. Page-Dumroese; Ned B. Klopfenstein
2015-01-01
Metagenomics has illuminated our understanding of how microbial communities influence health and disease. Researchers are beginning to characterize what constitutes healthy microbiota in terms of structure, function, and diversity in a variety of environments. Although investigation lags behind the more well-studied human microbiome, a growing body of research is using...
The National Institutes of Health Common Fund announces two new Funding Opportunity Announcements with a focus on the Illuminating the Druggable Genome (IDG). These funding opportunities are designed to foster the development of technologies and information management to facilitate the unveiling of the functions of the poorly characterized and/or un-annotated members in four protein classes of the Druggable Genome. The IDG project is predicated on the need to fully explore the underlying biology and role in disease of genes linked to already drugged genes within the Druggable Genome.
Hoffman, Robert W; Merrill, Joan T; Alarcón-Riquelme, Marta M E; Petri, Michelle; Dow, Ernst R; Nantz, Eric; Nisenbaum, Laura K; Schroeder, Krista M; Komocsar, Wendy J; Perumal, Narayanan B; Linnik, Matthew D; Airey, David C; Liu, Yushi; Rocha, Guilherme V; Higgs, Richard E
2017-03-01
To characterize baseline gene expression and pharmacodynamically induced changes in whole blood gene expression in 1,760 systemic lupus erythematosus (SLE) patients from 2 phase III, 52-week, randomized, placebo-controlled, double-blind studies in which patients were treated with the BAFF-blocking IgG4 monoclonal antibody tabalumab. Patient samples were obtained from SLE patients from the ILLUMINATE-1 and ILLUMINATE-2 studies, and control samples were obtained from healthy donors. Blood was collected in Tempus tubes at baseline, week 16, and week 52. RNA was analyzed using Affymetrix Human Transcriptome Array 2.0 and NanoString. At baseline, expression of the interferon (IFN) response gene was elevated in patients compared with controls, with 75% of patients being positive for this IFN response gene signature. There was, however, substantial heterogeneity of IFN response gene expression and complex relationships among gene networks. The IFN response gene signature was a predictor of time to disease flare, independent of anti-double-stranded DNA (anti-dsDNA) antibody and C3 and C4 levels, and overall disease activity. Pharmacodynamically induced changes in gene expression following tabalumab treatment were extensive, occurring predominantly in B cell-related and immunoglobulin genes, and were consistent with other pharmacodynamic changes including anti-dsDNA antibody, C3, and immunoglobulin levels. SLE patients demonstrated increased expression of an IFN response gene signature (75% of patients had an elevated IFN response gene signature) at baseline in ILLUMINATE-1 and ILLUMINATE-2. Substantial heterogeneity of gene expression was detected among individual patients and in gene networks. The IFN response gene signature was an independent risk factor for future disease flares. Pharmacodynamic changes in gene expression were consistent with the mechanism of BAFF blockade by tabalumab. © 2016, American College of Rheumatology.
Measuring the retina optical properties using a structured illumination imaging system
NASA Astrophysics Data System (ADS)
Basiri, A.; Nguyen, T. A.; Ibrahim, M.; Nguyen, Q. D.; Ramella-Roman, Jessica C.
2011-03-01
Patients with diabetic retinopathy (DR) may experience a reduction in retinal oxygen saturation (SO2). Close monitoring with a fundus ophthalmoscope can help in the prediction of the progression of disease. In this paper we present a noninvasive instrument based on structured illumination aimed at measuring the retina optical properties including oxygen saturation. The instrument uses two wavelngths one in the NIR and one visible, a fast acquisition camera, and a splitter system that allows for contemporaneous collection of images at two different wavelengths. This scheme greatly reduces eye movement artifacts. Structured illumination was achieved in two different ways, firstly several binary illumination masks fabricated using laser micro-machining were used, a near-sinusoidal projection pattern is ultimately achieved at the image plane by appropriate positioning of the binary masks. Secondarily a sinusoidal pattern printed on a thin plastic sheet was positioned at image plane of a fundus ophthalmoscope. The system was calibrated using optical phantoms of known optical properties as well as an eye phantom that included a 150μm capillary vessel containing different concentrations of oxygenated and deoxygenated hemoglobin.
Highly Resolved Intravital Striped-illumination Microscopy of Germinal Centers
Andresen, Volker; Sporbert, Anje
2014-01-01
Monitoring cellular communication by intravital deep-tissue multi-photon microscopy is the key for understanding the fate of immune cells within thick tissue samples and organs in health and disease. By controlling the scanning pattern in multi-photon microscopy and applying appropriate numerical algorithms, we developed a striped-illumination approach, which enabled us to achieve 3-fold better axial resolution and improved signal-to-noise ratio, i.e. contrast, in more than 100 µm tissue depth within highly scattering tissue of lymphoid organs as compared to standard multi-photon microscopy. The acquisition speed as well as photobleaching and photodamage effects were similar to standard photo-multiplier-based technique, whereas the imaging depth was slightly lower due to the use of field detectors. By using the striped-illumination approach, we are able to observe the dynamics of immune complex deposits on secondary follicular dendritic cells – on the level of a few protein molecules in germinal centers. PMID:24748007
Lee, Seungah; Nan, He; Yu, Hyunung; Kang, Seong Ho
2016-05-15
A nanoimmunosensor based on wavelength-dependent dark-field illumination with enhanced sensitivity was used to detect a disease-related protein molecule at zeptomolar (zM) concentrations. The assay platform of 100-nm gold nanospots could be selectively acquired using the wavelength-dependence of enhanced scattering signals from antibody-conjugated plasmonic silver nanoparticles (NPs) with on-off switching using optical filters. Detection of human thyroid-stimulating hormone (hTSH) at a sensitivity of 100 zM, which corresponds to 1-2 molecules per gold spot, was possible within a linear range of 100 zM-100 fM (R=0.9968). A significantly enhanced sensitivity (~4-fold) was achieved with enhanced dark-field illumination compared to using a total internal reflection fluorescence immunosensor. Immunoreactions were confirmed via optical axial-slicing based on the spectral characteristics of two plasmonic NPs. This method of using wavelength-dependent dark-field illumination had an enhanced sensitivity and a wide, linear dynamic range of 100 zM-100 fM, and was an effective tool for quantitatively detecting a single molecule on a nanobiochip for molecular diagnostics. Copyright © 2016 Elsevier B.V. All rights reserved.
Structured illumination microscopy as a diagnostic tool for nephrotic disease
NASA Astrophysics Data System (ADS)
Nylk, Jonathan; Pullman, James M.; Campbell, Elaine C.; Gunn-Moore, Frank J.; Prystowsky, Michael B.; Dholakia, Kishan
2017-02-01
Nephrotic disease is a group of debilitating and sometimes lethal diseases affecting kidney function, specifically the loss of ability to retain vital proteins in the blood while smaller molecules are removed through filtration into the urine. Treatment routes are often dictated by microscopic analysis of kidney biopsies. Podocytes within the glomeruli of the kidney have many interdigitating projections (foot processes), which form the main filtration system. Nephrotic disease is characterised by the loss of this tightly interdigitating substructure and its observation by electron microscopy (EM) is necessitated as these structures are typically 250 500nm wide, with 40nm spacing. Diagnosis by EM is both expensive and time consuming; it can take up to one week to complete the preparation, imaging, and analysis of a single sample. We propose structured illumination microscopy (SIM) as an alternative, optical diagnostic tool. Our results show that SIM can resolve the structure of fluorescent probes tagged to podocin, a protein localised to the periphery of the podocyte foot processes. Three-dimensional podocin maps were acquired in healthy tissue and tissue from patients diagnosed with two different nephrotic disease states; minimal change disease and membranous nephropathy. These structures correlated well with EM images of the same structure. Preparation, imaging, and analysis could be achieved in several hours. Additionally, the volumetric information of the SIM images revealed morphological changes in disease states not observed by EM. This evidence supports the use of SIM as a diagnostic tool for nephrotic disease and can potentially reduce the time and cost per diagnosis.
Red and NIR light dosimetry in the human deep brain
NASA Astrophysics Data System (ADS)
Pitzschke, A.; Lovisa, B.; Seydoux, O.; Zellweger, M.; Pfleiderer, M.; Tardy, Y.; Wagnières, G.
2015-04-01
Photobiomodulation (PBM) appears promising to treat the hallmarks of Parkinson’s Disease (PD) in cellular or animal models. We measured light propagation in different areas of PD-relevant deep brain tissue during transcranial, transsphenoidal illumination (at 671 and 808 nm) of a cadaver head and modeled optical parameters of human brain tissue using Monte-Carlo simulations. Gray matter, white matter, cerebrospinal fluid, ventricles, thalamus, pons, cerebellum and skull bone were processed into a mesh of the skull (158 × 201 × 211 voxels; voxel side length: 1 mm). Optical parameters were optimized from simulated and measured fluence rate distributions. The estimated μeff for the different tissues was in all cases larger at 671 than at 808 nm, making latter a better choice for light delivery in the deep brain. Absolute values were comparable to those found in the literature or slightly smaller. The effective attenuation in the ventricles was considerably larger than literature values. Optimization yields a new set of optical parameters better reproducing the experimental data. A combination of PBM via the sphenoid sinus and oral cavity could be beneficial. A 20-fold higher efficiency of light delivery to the deep brain was achieved with ventricular instead of transcranial illumination. Our study demonstrates that it is possible to illuminate deep brain tissues transcranially, transsphenoidally and via different application routes. This opens therapeutic options for sufferers of PD or other cerebral diseases necessitating light therapy.
Water hardness affects catfish susceptibility to columnaris
USDA-ARS?s Scientific Manuscript database
Columnaris disease can cause tremendous losses of freshwater fish. While it has been studied exhaustively, little is known about its affinity to specific water chemistries that affects attachment. Recent studies in our labs have illuminated this subject. In the first experiment, two waters were ...
Veigh, Clare Mc; Reid, Joanne; Larkin, Philip; Porter, Sam; Hudson, Peter
2017-07-11
Previous research and key guidelines have suggested potential models of palliative care for patients with COPD and interstitial lung disease. However, these recommendations are often not effectively implemented in clinical practice and are void of guidance regarding palliative care for patients with bronchiectasis, another form of non-malignant respiratory disease. The aim of this research was to explore generalist and specialist palliative care service provision for people with non-malignant respiratory disease in the North and Republic of Ireland. Qualitative study involving a convenience sample of 17 bereaved carers and 18 healthcare professionals recruited from 2 rural and 2 urban sites on the Island of Ireland. Data collection consisted of semi-structured interviews with carers of patients with COPD, interstitial lung disease or bronchiectasis who had died 3-18 months previously; and 4 focus groups with healthcare professionals. Data analysed using thematic analysis. Findings highlighted the lack of a clear model of holistic care delivery for patients with non-malignant respiratory disease and illuminated the varying levels of palliative care provision this client group experienced. Additionally, ambiguity amongst healthcare professionals regarding prognostication illuminated the importance of the provision of palliative care being based on patient need, not prognosis. This research developed a potential model of palliative care which may help healthcare professionals introduce palliative care, and specialist respiratory care, early in the disease trajectory of non-malignant respiratory disease, whilst also encouraging the involvement of specialist palliative care for complex symptom management. This research provides an important insight into a potential model of palliative care for people with non-malignant respiratory disease, inclusive of bronchiectasis. However, the feasibility of integrating this model into clinical practice requires further exploration.
Skin image illumination modeling and chromophore identification for melanoma diagnosis
NASA Astrophysics Data System (ADS)
Liu, Zhao; Zerubia, Josiane
2015-05-01
The presence of illumination variation in dermatological images has a negative impact on the automatic detection and analysis of cutaneous lesions. This paper proposes a new illumination modeling and chromophore identification method to correct lighting variation in skin lesion images, as well as to extract melanin and hemoglobin concentrations of human skin, based on an adaptive bilateral decomposition and a weighted polynomial curve fitting, with the knowledge of a multi-layered skin model. Different from state-of-the-art approaches based on the Lambert law, the proposed method, considering both specular reflection and diffuse reflection of the skin, enables us to address highlight and strong shading effects usually existing in skin color images captured in an uncontrolled environment. The derived melanin and hemoglobin indices, directly relating to the pathological tissue conditions, tend to be less influenced by external imaging factors and are more efficient in describing pigmentation distributions. Experiments show that the proposed method gave better visual results and superior lesion segmentation, when compared to two other illumination correction algorithms, both designed specifically for dermatological images. For computer-aided diagnosis of melanoma, sensitivity achieves 85.52% when using our chromophore descriptors, which is 8~20% higher than those derived from other color descriptors. This demonstrates the benefit of the proposed method for automatic skin disease analysis.
ERIC Educational Resources Information Center
Morse, A. R.; And Others
1987-01-01
Eye diseases of the aged include diabetic retinopathy, senile cataracts, senile macular degeneration, and glaucoma. Environmental modifications such as better levels of illumination and reduction of glare can enhance an individual's ability to function. Programs to screen and treat visual problems in elderly persons are called for. (Author/JDD)
NASA Astrophysics Data System (ADS)
Uzunov, Tzonko; Gizbreht, Alexander I.; Nenchev, Marin N.
1996-12-01
The results of the measurement of the penetration of the laser light inside dental configurations are reported. The illumination of the pulp chamber is carried out. The results can be employed in clinical practice for dosage in treatment of periodontal diseases.
Ebola images emerge from the cave.
Diamond, Michael S; Fremont, Daved H
2008-08-14
Ebola virus causes a lethal hemorrhagic disease for which no therapy or vaccine is currently approved. Recently, the crystal structure of the Ebola virus glycoprotein in complex with a human neutralizing antibody was illuminated, providing a path from the shadows toward understanding cellular attachment, viral fusion, and immune evasion.
Laser scattering by transcranial rat brain illumination
NASA Astrophysics Data System (ADS)
Sousa, Marcelo V. P.; Prates, Renato; Kato, Ilka T.; Sabino, Caetano P.; Suzuki, Luis C.; Ribeiro, Martha S.; Yoshimura, Elisabeth M.
2012-06-01
Due to the great number of applications of Low-Level-Laser-Therapy (LLLT) in Central Nervous System (CNS), the study of light penetration through skull and distribution in the brain becomes extremely important. The aim is to analyze the possibility of precise illumination of deep regions of the rat brain, measure the penetration and distribution of red (λ = 660 nm) and Near Infra-Red (NIR) (λ = 808 nm) diode laser light and compare optical properties of brain structures. The head of the animal (Rattus Novergicus) was epilated and divided by a sagittal cut, 2.3 mm away from mid plane. This section of rat's head was illuminated with red and NIR lasers in points above three anatomical structures: hippocampus, cerebellum and frontal cortex. A high resolution camera, perpendicularly positioned, was used to obtain images of the brain structures. Profiles of scattered intensities in the laser direction were obtained from the images. There is a peak in the scattered light profile corresponding to the skin layer. The bone layer gives rise to a valley in the profile indicating low scattering coefficient, or frontal scattering. Another peak in the region related to the brain is an indication of high scattering coefficient (μs) for this tissue. This work corroborates the use of transcranial LLLT in studies with rats which are subjected to models of CNS diseases. The outcomes of this study point to the possibility of transcranial LLLT in humans for a large number of diseases.
The Memory Ensemble: Improvising Connections among Performance, Disability, and Ageing
ERIC Educational Resources Information Center
Dunford, Christine Mary; Yoshizaki-Gibbons, Hailee M.; Morhardt, Darby
2017-01-01
There is a recognised need for research that illuminates mutually beneficial connections among performance, ageing, disability theory, and praxis. One such project is the Memory Ensemble™, an improvisational theatre intervention for persons with early stage Alzheimer's disease and related dementias (ADRD). This case study explores how the…
The influence of water chemistries on Flavobacterium columnare pathogenesis in channel catfish
USDA-ARS?s Scientific Manuscript database
Columnaris disease can cause tremendous losses of freshwater fish. While it has been studied exhaustively, little is known about its affinity to specific water chemistries that affects attachment. Recent studies in our labs have illuminated this subject. In the first experiment, two waters were u...
USDA-ARS?s Scientific Manuscript database
Because disease can be devastating to crops, growers often spray fungicides as preventative measures. Unfortunately, many sprays are applied to in-bloom crops, which expose bees to fungicide residues. Generally considered “bee-safe,” fungicides are applied globally on flowering crops. However, there...
Polarized hyperspectral imaging system for in vivo detection of vulvar lichen sclerosis
NASA Astrophysics Data System (ADS)
Qu, Yingjie; Ren, Wenqi; Liu, Songde; Liu, Peng; Xie, Lan; Zhang, Xiaoyuan; Zhang, Shiwu; Chang, Shufang; Xu, Ronald
2016-03-01
Vulvar lichen sclerosis (VLS) is a chronic, inflammatory and mucocutaneous disease of extragenital skin, which often goes undetected for years. The underlying causes are associated with the decrease of VEGF that reduces the blood oxygenation of vulva and the structural changes in the collagen fibrils, which can lead to scarring of the affected area. However, few methods are available for quantitative detection of VLS. Clinician's examinations are subjective and may lead to misdiagnosis. Spectroscopy is a potentially effective method for noninvasive detection of VLS. In this paper, we developed a polarized, hyperspectral imaging system for quantitative assessment. The system utilized a hyperspectral camera to collect the reflectance images of the entire vulva under Xenon lamp illumination with and without a polarizer in front of the fiber. One image (Ipar) acquired with the AOTF parallel to the polarization of illumination and the other image (Iper) acquired with the AOTF perpendicular to the illumination. This paper compares polarized images of VLS in a pilot clinical study. The collected reflectance data under Xenon lamp illumination without a polarizer are calibrated and the hyperspectral signals are extracted. An IRB approved clinical trial was carried out to evaluate the clinical utility for VLS detection. Our pilot study has demonstrated the technical potential of using this polarized hyperspectral imaging system for in vivo detection of vulvar lichen sclerosis.
Light pollution: the possible consequences of excessive illumination on retina.
Contín, M A; Benedetto, M M; Quinteros-Quintana, M L; Guido, M E
2016-02-01
Light is the visible part of the electromagnetic radiation within a range of 380-780 nm; (400-700 on primates retina). In vertebrates, the retina is adapted to capturing light photons and transmitting this information to other structures in the central nervous system. In mammals, light acts directly on the retina to fulfill two important roles: (1) the visual function through rod and cone photoreceptor cells and (2) non-image forming tasks, such as the synchronization of circadian rhythms to a 24 h solar cycle, pineal melatonin suppression and pupil light reflexes. However, the excess of illumination may cause retinal degeneration or accelerate genetic retinal diseases. In the last century human society has increased its exposure to artificial illumination, producing changes in the Light/Dark cycle, as well as in light wavelengths and intensities. Although, the consequences of unnatural illumination or light pollution have been underestimated by modern society in its way of life, light pollution may have a strong impact on people's health. The effects of artificial light sources could have direct consequences on retinal health. Constant exposure to different wavelengths and intensities of light promoted by light pollution may produce retinal degeneration as a consequence of photoreceptor or retinal pigment epithelium cells death. In this review we summarize the different mechanisms of retinal damage related to the light exposure, which generates light pollution.
Light pollution: the possible consequences of excessive illumination on retina
Contín, M A; Benedetto, M M; Quinteros-Quintana, M L; Guido, M E
2016-01-01
Light is the visible part of the electromagnetic radiation within a range of 380–780 nm; (400–700 on primates retina). In vertebrates, the retina is adapted to capturing light photons and transmitting this information to other structures in the central nervous system. In mammals, light acts directly on the retina to fulfill two important roles: (1) the visual function through rod and cone photoreceptor cells and (2) non-image forming tasks, such as the synchronization of circadian rhythms to a 24 h solar cycle, pineal melatonin suppression and pupil light reflexes. However, the excess of illumination may cause retinal degeneration or accelerate genetic retinal diseases. In the last century human society has increased its exposure to artificial illumination, producing changes in the Light/Dark cycle, as well as in light wavelengths and intensities. Although, the consequences of unnatural illumination or light pollution have been underestimated by modern society in its way of life, light pollution may have a strong impact on people's health. The effects of artificial light sources could have direct consequences on retinal health. Constant exposure to different wavelengths and intensities of light promoted by light pollution may produce retinal degeneration as a consequence of photoreceptor or retinal pigment epithelium cells death. In this review we summarize the different mechanisms of retinal damage related to the light exposure, which generates light pollution. PMID:26541085
NASA Astrophysics Data System (ADS)
Viard, Clément; Nakashima, Kiyoko; Lamory, Barbara; Pâques, Michel; Levecq, Xavier; Château, Nicolas
2011-03-01
This research is aimed at characterizing in vivo differences between healthy and pathological retinal tissues at the microscopic scale using a compact adaptive optics (AO) retinal camera. Tests were performed in 120 healthy eyes and 180 eyes suffering from 19 different pathological conditions, including age-related maculopathy (ARM), glaucoma and rare diseases such as inherited retinal dystrophies. Each patient was first examined using SD-OCT and infrared SLO. Retinal areas of 4°x4° were imaged using an AO flood-illumination retinal camera based on a large-stroke deformable mirror. Contrast was finally enhanced by registering and averaging rough images using classical algorithms. Cellular-resolution images could be obtained in most cases. In ARM, AO images revealed granular contents in drusen, which were invisible in SLO or OCT images, and allowed the observation of the cone mosaic between drusen. In glaucoma cases, visual field was correlated to changes in cone visibility. In inherited retinal dystrophies, AO helped to evaluate cone loss across the retina. Other microstructures, slightly larger in size than cones, were also visible in several retinas. AO provided potentially useful diagnostic and prognostic information in various diseases. In addition to cones, other microscopic structures revealed by AO images may also be of interest in monitoring retinal diseases.
Elucidating the triggers, progression, and effects of Alzheimer's disease.
Medeiros, Rodrigo; Chabrier, Meredith A; LaFerla, Frank M
2013-01-01
As the number of patients with Alzheimer's disease (AD) continues to rise, the need for efficacious therapeutics is becoming more and more urgent. Understanding the molecular relationship and interactions between Aβ and tau and their contribution to cognitive decline remain one of the most fundamental and unresolved questions in the AD field. Likewise, elucidating the initial triggers of disease pathology, as well as the impact of various factors such as stress and inflammation on disease progression, are equally important to fully understand this devastating disorder. Here we discuss recent studies that have illuminated the importance of key facilitators of disease progression using the 3xTg-AD and CaM/Tet-DTA mouse models, and suggest viable targets for ameliorating both molecular pathology and cognitive decline.
Sapronosis: a distinctive type of infectious agent
Kuris, Armand M.; Lafferty, Kevin D.; Sokolow, Susanne H.
2014-01-01
Sapronotic disease agents have evolutionary and epidemiological properties unlike other infectious organisms. Their essential saprophagic existence prevents coevolution, and no host–parasite virulence trade-off can evolve. However, the host may evolve defenses. Models of pathogens show that sapronoses, lacking a threshold of transmission, cannot regulate host populations, although they can reduce host abundance and even extirpate their hosts. Immunocompromised hosts are relatively susceptible to sapronoses. Some particularly important sapronoses, such as cholera and anthrax, can sustain an epidemic in a host population. However, these microbes ultimately persist as saprophages. One-third of human infectious disease agents are sapronotic, including nearly all fungal diseases. Recognition that an infectious disease is sapronotic illuminates a need for effective environmental control strategies.
Blonz, Edward R.
2017-01-01
The decreased availability of metabolizable energy resources in the central nervous system is hypothesized to be a key factor in the pathogenesis of Alzheimer’s disease. More specifically, the age-related decline in the ability of glucose to cross the blood-brain barrier creates a metabolic stress that shifts the normal, benign processing of amyloid-β protein precursor toward pathways associated with the production of amyloid-β plaques and tau-containing neurofibrillary tangles that are characteristic of the disease. The neuroenergetic hypothesis provides insight into the etiology of Alzheimer’s disease and illuminates new approaches for diagnosis, monitoring, and treatment. PMID:28946565
Demand illumination control apparatus
NASA Technical Reports Server (NTRS)
Warren, Carl (Inventor); Arline, Jimmie (Inventor); LaPalme, Julius (Inventor)
1981-01-01
Solar illuminating compensating apparatus is disclosed whereby the interior of a building is illuminated to a substantially constant, predetermined level of light intensity by a combination of natural illumination from the sun and artificial illumination from electricity wherein the intensity of said artificial illumination is controlled by fully electronic means which increases the level of artificial illumination when the natural illumination is inadequate and vice versa.
Therapy-Related Myeloid Neoplasms: When Genetics and Environment Collide
McNerney, Megan E.; Godley, Lucy A.; Le Beau, Michelle M.
2018-01-01
Therapy-related myeloid neoplasms (t-MN) arise as a late-effect of chemotherapy and/or radiation administered for a primary condition, typically a malignant disease, solid organ transplant, or autoimmune disease. Survival is measured in months, not years, making t-MN one of the most aggressive and lethal cancers. In this review, we discuss recent developments that reframe our understanding of the genetic and environmental etiology of t-MN. Emerging data illuminate who is at highest risk for developing t-MN, why t-MN is chemoresistant, and how we may use this information to treat and ultimately prevent this dreaded disease. PMID:28835720
Illuminating Neural Circuits: From Molecules to MRI.
Lee, Jin Hyung; Kreitzer, Anatol C; Singer, Annabelle C; Schiff, Nicholas D
2017-11-08
Neurological disease drives symptoms through pathological changes to circuit functions. Therefore, understanding circuit mechanisms that drive behavioral dysfunction is of critical importance for quantitative diagnosis and systematic treatment of neurological disease. Here, we describe key technologies that enable measurement and manipulation of neural activity and neural circuits. Applying these approaches led to the discovery of circuit mechanisms underlying pathological motor behavior, arousal regulation, and protein accumulation. Finally, we discuss how optogenetic functional magnetic resonance imaging reveals global scale circuit mechanisms, and how circuit manipulations could lead to new treatments of neurological diseases. Copyright © 2017 the authors 0270-6474/17/3710817-09$15.00/0.
USDA-ARS?s Scientific Manuscript database
A good understanding of pathogen transmission in a host population should illuminate methods for disease prevention and control. A case in point for this is the alfalfa leafcutting bee (Megachile rotundata), a solitary bee which is used extensively for pollination of alfalfa grown for seed. Propaga...
Non-contact finger vein acquisition system using NIR laser
NASA Astrophysics Data System (ADS)
Kim, Jiman; Kong, Hyoun-Joong; Park, Sangyun; Noh, SeungWoo; Lee, Seung-Rae; Kim, Taejeong; Kim, Hee Chan
2009-02-01
Authentication using finger vein pattern has substantial advantage than other biometrics. Because human vein patterns are hidden inside the skin and tissue, it is hard to forge vein structure. But conventional system using NIR LED array has two drawbacks. First, direct contact with LED array raise sanitary problem. Second, because of discreteness of LEDs, non-uniform illumination exists. We propose non-contact finger vein acquisition system using NIR laser and Laser line generator lens. Laser line generator lens makes evenly distributed line laser from focused laser light. Line laser is aimed on the finger longitudinally. NIR camera was used for image acquisition. 200 index finger vein images from 20 candidates are collected. Same finger vein pattern extraction algorithm was used to evaluate two sets of images. Acquired images from proposed non-contact system do not show any non-uniform illumination in contrary with conventional system. Also results of matching are comparable to conventional system. We developed Non-contact finger vein acquisition system. It can prevent potential cross contamination of skin diseases. Also the system can produce uniformly illuminated images unlike conventional system. With the benefit of non-contact, proposed system shows almost equivalent performance compared with conventional system.
Retinal image restoration by means of blind deconvolution
NASA Astrophysics Data System (ADS)
Marrugo, Andrés G.; Šorel, Michal; Šroubek, Filip; Millán, María S.
2011-11-01
Retinal imaging plays a key role in the diagnosis and management of ophthalmologic disorders, such as diabetic retinopathy, glaucoma, and age-related macular degeneration. Because of the acquisition process, retinal images often suffer from blurring and uneven illumination. This problem may seriously affect disease diagnosis and progression assessment. Here we present a method for color retinal image restoration by means of multichannel blind deconvolution. The method is applied to a pair of retinal images acquired within a lapse of time, ranging from several minutes to months. It consists of a series of preprocessing steps to adjust the images so they comply with the considered degradation model, followed by the estimation of the point-spread function and, ultimately, image deconvolution. The preprocessing is mainly composed of image registration, uneven illumination compensation, and segmentation of areas with structural changes. In addition, we have developed a procedure for the detection and visualization of structural changes. This enables the identification of subtle developments in the retina not caused by variation in illumination or blur. The method was tested on synthetic and real images. Encouraging experimental results show that the method is capable of significant restoration of degraded retinal images.
Toward unraveling the complexity of simple epithelial keratins in human disease.
Omary, M Bishr; Ku, Nam-On; Strnad, Pavel; Hanada, Shinichiro
2009-07-01
Simple epithelial keratins (SEKs) are found primarily in single-layered simple epithelia and include keratin 7 (K7), K8, K18-K20, and K23. Genetically engineered mice that lack SEKs or overexpress mutant SEKs have helped illuminate several keratin functions and served as important disease models. Insight into the contribution of SEKs to human disease has indicated that K8 and K18 are the major constituents of Mallory-Denk bodies, hepatic inclusions associated with several liver diseases, and are essential for inclusion formation. Furthermore, mutations in the genes encoding K8, K18, and K19 predispose individuals to a variety of liver diseases. Hence, as we discuss here, the SEK cytoskeleton is involved in the orchestration of several important cellular functions and contributes to the pathogenesis of human liver disease.
Toward unraveling the complexity of simple epithelial keratins in human disease
Omary, M. Bishr; Ku, Nam-On; Strnad, Pavel; Hanada, Shinichiro
2009-01-01
Simple epithelial keratins (SEKs) are found primarily in single-layered simple epithelia and include keratin 7 (K7), K8, K18–K20, and K23. Genetically engineered mice that lack SEKs or overexpress mutant SEKs have helped illuminate several keratin functions and served as important disease models. Insight into the contribution of SEKs to human disease has indicated that K8 and K18 are the major constituents of Mallory-Denk bodies, hepatic inclusions associated with several liver diseases, and are essential for inclusion formation. Furthermore, mutations in the genes encoding K8, K18, and K19 predispose individuals to a variety of liver diseases. Hence, as we discuss here, the SEK cytoskeleton is involved in the orchestration of several important cellular functions and contributes to the pathogenesis of human liver disease. PMID:19587454
Could Sensory Mechanisms Be a Core Factor That Underlies Freezing of Gait in Parkinson’s Disease?
Ehgoetz Martens, Kaylena A.; Pieruccini-Faria, Frederico; Almeida, Quincy J.
2013-01-01
The main objective of this study was to determine how manipulating the amount of sensory information available about the body and surrounding environment influenced freezing of gait (FOG), while walking through a doorway. It was hypothesized that the more limited the sensory information, the greater the occurrence of freezing of gait. Nineteen patients with Parkinsoǹs disease who experience freezing of gait (PD-FOG) walked through a doorway or into open space in complete darkness. The three doorway conditions included: (i) FRAME (DARK) – walking through the remembered door frame; (ii) FRAME - walking through the door with the door frame illuminated; (iii) FRAME+BODY - walking through the door (both the door and the limbs illuminated). Additionally, two conditions of walking away from the doorway included: (iv) NO FRAME (DARK) - walking into open space; (v) NO FRAME+BODY - walking into open space with the limbs illuminated, to evaluate whether perception (or fear) of the doorway might account for FOG behaviour. Key outcome measures included: the number of freezing of gait episodes recorded, total duration of freezing of gait, and the percentage of time spent frozen. Significantly more freezing of gait episodes occurred when participants walked toward the doorway in complete darkness compared to walking into open space (p<0.05). Similar to previous studies, velocity (p<0.001) and step length (p<0.0001) significantly decreased when walking through the door in complete darkness, compared to all other conditions. Significant increases in step width variability were also identified but only when walking into open space (p<0.005). These results support the notion that sensory deficits may have a profound impact on freezing of gait that need to be carefully considered. PMID:23667499
Wavelength dependence of the apparent diameter of retinal blood vessels
NASA Astrophysics Data System (ADS)
Park, Robert; Twietmeyer, Karen; Chipman, Russell; Beaudry, Neil; Salyer, David
2005-04-01
Imaging of retinal blood vessels may assist in the diagnosis and monitoring of diseases such as glaucoma, diabetic retinopathy, and hypertension. However, close examination reveals that the contrast and apparent diameter of vessels are dependent on the wavelength of the illuminating light. In this study multispectral images of large arteries and veins within enucleated swine eyes are obtained with a modified fundus camera by use of intravitreal illumination. The diameters of selected vessels are measured as a function of wavelength by cross-sectional analysis. A fixed scale with spectrally independent dimension is placed above the retina to isolate the chromatic effects of the imaging system and eye. Significant apparent differences between arterial and venous diameters are found, with larger diameters observed at shorter wavelengths. These differences are due primarily to spectral absorption in the cylindrical blood column.
Testing optimum viewing conditions for mammographic image displays.
Waynant, R W; Chakrabarti, K; Kaczmarek, R A; Dagenais, I
1999-05-01
The viewbox luminance and viewing room light level are important parameters in a medical film display, but these parameters have not had much attention. Spatial variations and too much room illumination can mask real signal or create the false perception of a signal. This presentation looks at how scotopic light sources and dark-adapted radiologists may identify more real diseases.
3D quantitative photoacoustic image reconstruction using Monte Carlo method and linearization
NASA Astrophysics Data System (ADS)
Okawa, Shinpei; Hirasawa, Takeshi; Tsujita, Kazuhiro; Kushibiki, Toshihiro; Ishihara, Miya
2018-02-01
To quantify the functional and structural information of peripheral blood vessels for diagnoses of diseases which affects peripheral blood vessels such as diabetes and peripheral vascular disease, a 3D quantitative photoacoustic tomography (QPAT) reconstructing the optical properties such as the absorption coefficient reflecting microvascular structures and hemoglobin concentration and oxygenation saturation is studied. QPAT image reconstruction algorithms based on radiative transfer equation (RTE) and photon diffusion equation (PDE) have been proposed. However, it is not easy to use RTE in the clinical practice because of the huge computational load and long calculation time. On the other hand, it is always considered problematic to use PDE, because it does not approximate RTE well near the illuminating position. In this study, we developed the 3D QPAT image reconstruction using Monte Carlo (MC) method which approximates RTE better than PDE to reconstruct the optical properties in the region near the illuminating surface. To reduce the calculation time, we applied linearization. The QPAT image reconstruction algorithm with MC method and linearization was examined in numerical simulations and phantom experiment by use of a scanning system with a single probe consisting of P(VDF-TrFE) piezo electric film and optical fiber.
Price, Jeffery R.; Bingham, Philip R.
2005-11-08
Systems and methods are described for rapid acquisition of fused off-axis illumination direct-to-digital holography. A method of recording a plurality of off-axis object illuminated spatially heterodyne holograms, each of the off-axis object illuminated spatially heterodyne holograms including spatially heterodyne fringes for Fourier analysis, includes digitally recording, with a first illumination source of an interferometer, a first off-axis object illuminated spatially heterodyne hologram including spatially heterodyne fringes for Fourier analysis; and digitally recording, with a second illumination source of the interferometer, a second off-axis object illuminated spatially heterodyne hologram including spatially heterodyne fringes for Fourier analysis.
Lee, Onseok; Park, Sunup; Kim, Jaeyoung; Oh, Chilhwan
2017-11-01
The visual scoring method has been used as a subjective evaluation of pigmentary skin disorders. Severity of pigmentary skin disease, especially melasma, is evaluated using a visual scoring method, the MASI (melasma area severity index). This study differentiates between epidermal and dermal pigmented disease. The study was undertaken to determine methods to quantitatively measure the severity of pigmentary skin disorders under ultraviolet illumination. The optical imaging system consists of illumination (white LED, UV-A lamp) and image acquisition (DSLR camera, air cooling CMOS CCD camera). Each camera is equipped with a polarizing filter to remove glare. To analyze images of visible and UV light, images are divided into frontal, cheek, and chin regions of melasma patients. Each image must undergo image processing. To reduce the curvature error in facial contours, a gradient mask is used. The new method of segmentation of front and lateral facial images is more objective for face-area-measurement than the MASI score. Image analysis of darkness and homogeneity is adequate to quantify the conventional MASI score. Under visible light, active lesion margins appear in both epidermal and dermal melanin, whereas melanin is found in the epidermis under UV light. This study objectively analyzes severity of melasma and attempts to develop new methods of image analysis with ultraviolet optical imaging equipment. Based on the results of this study, our optical imaging system could be used as a valuable tool to assess the severity of pigmentary skin disease. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Shen, Y. Z.; Guo, S. S.; Ai, W. D.; Tang, Y. K.
2014-07-01
Effects of illuminants and illumination time on the growth of lettuce were researched. Red-blue light-emitting diodes (LEDs, 90% red light +10% blue light) and white light fluorescent (WF) lamps were compared as the illuminants for plant cultivation. Under each type of illuminant, lettuce was grown at 4 illumination times: 12 h, 16 h, 20 h and 24 h, with the same light intensity of 600 μmolm-2s-1. The leaf net photosynthetic rate (Pn) under the two illuminants was comparable but the shape of lettuce was obviously affected by the illuminant. The WF lamps produced more compact plant, while red-blue LED resulted in less but longer leaves. However, the total leaf area was not significantly affected by the illuminant. The red-blue LED produced nearly same aboveground biomass with far less energy consumption relative to WF lamps. The underground biomass was lowered under red-blue LED in comparison with WF lamps. Red-blue LED could improve the nutritional quality of lettuce by increasing the concentration of soluble sugar and vitamin C (VC) and reducing the concentration of nitrate. Under each type of illuminant, longer illumination time resulted in higher Pn, more leaves and larger leaf area. The total chlorophyll concentration increased while the concentration ratio of chlorophyll a/b decreased with the extension of illumination time. Illumination time had highly significant positive correlation with biomass. Moreover, when total daily light input was kept the same, longer illumination time increased the biomass significantly as well. In addition, longer illumination time increased the concentration of crude fiber, soluble sugar and VC and reduced the concentration of nitrate. In summary, red-blue LEDs and 24 h illumination time were demonstrated to be more suitable for lettuce cultivation in the controlled environment.
[The role of neurotrophic factors in regeneration of the nervous system].
Machaliński, Bogusław; Lażewski-Banaszak, Piotr; Dąbkowska, Elżbieta; Paczkowska, Edyta; Gołąb-Janowska, Monika; Nowacki, Przemysław
2012-01-01
Neurotrophic factors regulate survival, development, and function of nervous tissue. They act via two different classes of receptors and activation of various signaling pathways in the target cells. Illumination of their physiological role in the maintenance of central nervous system homeostasis as well as regeneration of damaged tissue have ignited expectations to heal neurodegenerative diseases, including amyotrophic late-ral sclerosis and Parkinson disease. Advances in pharmaco-therapy, gene therapy, and stem cell biology have enabled development of novel therapies with application of regenerating cell transplantation. In the foreseeable future, it may lead to the establishment of safe and effective ways of treatment of these severe and currently incurable diseases.
Multispectral imaging of the ocular fundus using light emitting diode illumination
NASA Astrophysics Data System (ADS)
Everdell, N. L.; Styles, I. B.; Calcagni, A.; Gibson, J.; Hebden, J.; Claridge, E.
2010-09-01
We present an imaging system based on light emitting diode (LED) illumination that produces multispectral optical images of the human ocular fundus. It uses a conventional fundus camera equipped with a high power LED light source and a highly sensitive electron-multiplying charge coupled device camera. It is able to take pictures at a series of wavelengths in rapid succession at short exposure times, thereby eliminating the image shift introduced by natural eye movements (saccades). In contrast with snapshot systems the images retain full spatial resolution. The system is not suitable for applications where the full spectral resolution is required as it uses discrete wavebands for illumination. This is not a problem in retinal imaging where the use of selected wavelengths is common. The modular nature of the light source allows new wavelengths to be introduced easily and at low cost. The use of wavelength-specific LEDs as a source is preferable to white light illumination and subsequent filtering of the remitted light as it minimizes the total light exposure of the subject. The system is controlled via a graphical user interface that enables flexible control of intensity, duration, and sequencing of sources in synchrony with the camera. Our initial experiments indicate that the system can acquire multispectral image sequences of the human retina at exposure times of 0.05 s in the range of 500-620 nm with mean signal to noise ratio of 17 dB (min 11, std 4.5), making it suitable for quantitative analysis with application to the diagnosis and screening of eye diseases such as diabetic retinopathy and age-related macular degeneration.
Multispectral imaging of the ocular fundus using light emitting diode illumination.
Everdell, N L; Styles, I B; Calcagni, A; Gibson, J; Hebden, J; Claridge, E
2010-09-01
We present an imaging system based on light emitting diode (LED) illumination that produces multispectral optical images of the human ocular fundus. It uses a conventional fundus camera equipped with a high power LED light source and a highly sensitive electron-multiplying charge coupled device camera. It is able to take pictures at a series of wavelengths in rapid succession at short exposure times, thereby eliminating the image shift introduced by natural eye movements (saccades). In contrast with snapshot systems the images retain full spatial resolution. The system is not suitable for applications where the full spectral resolution is required as it uses discrete wavebands for illumination. This is not a problem in retinal imaging where the use of selected wavelengths is common. The modular nature of the light source allows new wavelengths to be introduced easily and at low cost. The use of wavelength-specific LEDs as a source is preferable to white light illumination and subsequent filtering of the remitted light as it minimizes the total light exposure of the subject. The system is controlled via a graphical user interface that enables flexible control of intensity, duration, and sequencing of sources in synchrony with the camera. Our initial experiments indicate that the system can acquire multispectral image sequences of the human retina at exposure times of 0.05 s in the range of 500-620 nm with mean signal to noise ratio of 17 dB (min 11, std 4.5), making it suitable for quantitative analysis with application to the diagnosis and screening of eye diseases such as diabetic retinopathy and age-related macular degeneration.
The role of nutrition in the prevention of coronary heart disease in women of the developed world.
Greene, Christine M; Fernandez, Maria Luz
2007-01-01
Cardiovascular disease claims more than 500,000 women per year, making this disease the number one killer of women. Coronary heart disease in developed countries can be used as a representative classification when discussing cardiovascular disease management. Within the last 10 years research has illuminated the contributing risk factors and disease progression as they uniquely relate to women. Yet, current approaches to the prevention of primary risk factors in the development of cardiovascular disease fail to reach the potential described in scientific literature. Traditional prescriptions relied on hormone therapy or pharmacologic intervention to manage coronary heart diseases ignoring the non-hormonal aspects of cardiovascular health. Recent trends have begun to emphasize diet as a tool for the prevention of heart disease in women. This review attempts to highlight nutrition as a prescription that can be utilized to reduce the significant risk factors that women, who live in developed nations, face throughout their lifetime.
Surface color perception under two illuminants: the second illuminant reduces color constancy
NASA Technical Reports Server (NTRS)
Yang, Joong Nam; Shevell, Steven K.
2003-01-01
This study investigates color perception in a scene with two different illuminants. The two illuminants, in opposite corners, simultaneously shine on a (simulated) scene with an opaque dividing wall, which controls how much of the scene is illuminated by each source. In the first experiment, the height of the dividing wall was varied. This changed the amount of each illuminant reaching objects on the opposite side of the wall. Results showed that the degree of color constancy decreased when a region on one side of the wall had cues to both illuminants, suggesting that cues from the second illuminant are detrimental to color constancy. In a later experiment, color constancy was found to improve when the specular highlight cues from the second illuminant were altered to be consistent with the first illuminant. This corroborates the influence of specular highlights in surface color perception, and suggests that the reduced color constancy in the first experiment is due to the inconsistent, though physically correct, cues from the two illuminants.
Timmermann, Carsten
2012-01-01
Summary Risk factors have become a dominant approach to the aetiology of chronic disease worldwide. The concept emerged in the new field of chronic disease epidemiology in the United States in the 1950s, around near-iconic projects such as the Framingham Heart Study. In this article I examine how chronic disease epidemiology and the risk factor concept were adopted and adapted in the two German states. I draw on case studies that illuminate the characteristics of the different contexts and different take on traditions in social hygiene, social medicine and epidemiology. I also look at critics of the risk factor approach in East and West Germany, who viewed risk factors as intellectually dishonest and a new surveillance tool.
The role of epigenetics in genetic and environmental epidemiology.
Ladd-Acosta, Christine; Fallin, M Daniele
2016-02-01
Epidemiology is the branch of science that investigates the causes and distribution of disease in populations in order to provide preventative measures and promote human health. The fields of genetic and environmental epidemiology primarily seek to identify genetic and environmental risk factors for disease, respectively. Epigenetics is emerging as an important piece of molecular data to include in these studies because it can provide mechanistic insights into genetic and environmental risk factors for disease, identify potential intervention targets, provide biomarkers of exposure, illuminate gene-environment interactions and help localize disease-relevant genomic regions. Here, we describe the importance of including epigenetics in genetic and environmental epidemiology studies, provide a conceptual framework when considering epigenetic data in population-based studies and touch upon the many challenges that lie ahead.
Jia, Zhilong; Liu, Ying; Guan, Naiyang; Bo, Xiaochen; Luo, Zhigang; Barnes, Michael R
2016-05-27
Drug repositioning, finding new indications for existing drugs, has gained much recent attention as a potentially efficient and economical strategy for accelerating new therapies into the clinic. Although improvement in the sensitivity of computational drug repositioning methods has identified numerous credible repositioning opportunities, few have been progressed. Arguably the "black box" nature of drug action in a new indication is one of the main blocks to progression, highlighting the need for methods that inform on the broader target mechanism in the disease context. We demonstrate that the analysis of co-expressed genes may be a critical first step towards illumination of both disease pathology and mode of drug action. We achieve this using a novel framework, co-expressed gene-set enrichment analysis (cogena) for co-expression analysis of gene expression signatures and gene set enrichment analysis of co-expressed genes. The cogena framework enables simultaneous, pathway driven, disease and drug repositioning analysis. Cogena can be used to illuminate coordinated changes within disease transcriptomes and identify drugs acting mechanistically within this framework. We illustrate this using a psoriatic skin transcriptome, as an exemplar, and recover two widely used Psoriasis drugs (Methotrexate and Ciclosporin) with distinct modes of action. Cogena out-performs the results of Connectivity Map and NFFinder webservers in similar disease transcriptome analyses. Furthermore, we investigated the literature support for the other top-ranked compounds to treat psoriasis and showed how the outputs of cogena analysis can contribute new insight to support the progression of drugs into the clinic. We have made cogena freely available within Bioconductor or https://github.com/zhilongjia/cogena . In conclusion, by targeting co-expressed genes within disease transcriptomes, cogena offers novel biological insight, which can be effectively harnessed for drug discovery and repositioning, allowing the grouping and prioritisation of drug repositioning candidates on the basis of putative mode of action.
Arnold, Sarah E J; Chittka, Lars
2012-07-01
Patchy illumination presents foraging animals with a challenge, as the targets being sought may appear to vary in colour depending on the illumination, compromising target identification. We sought to explore how the bumblebee Bombus terrestris copes with tasks involving flower colour discrimination under patchy illumination. Light patches varied between unobscured daylight and leaf-shade, as a bee might encounter in and around woodland. Using a flight arena and coloured filters, as well as one or two different colours of artificial flower, we quantified how bees chose to forage when presented with foraging tasks under patchy illumination. Bees were better at discriminating a pair of similar colours under simulated unobscured daylight illumination than when foraging under leaf-shade illumination. Accordingly, we found that bees with prior experience of simulated daylight but not leaf-shade illumination initially preferred to forage in simulated daylight when all artificial flowers contained rewards as well as when only one colour was rewarding, whereas bees with prior experience of both illuminants did not exhibit this preference. Bees also switched between illuminants less than expected by chance. This means that bees prefer illumination conditions with which they are familiar, and in which rewarding flower colours are easily distinguishable from unrewarding ones. Under patchy illumination, colour discrimination performance was substantially poorer than in homogenous light. The bees' abilities at coping with patchy light may therefore impact on foraging behaviour in the wild, particularly in woodlands, where illumination can change over short spatial scales.
Retinal axial focusing and multi-layer imaging with a liquid crystal adaptive optics camera
NASA Astrophysics Data System (ADS)
Liu, Rui-Xue; Zheng, Xian-Liang; Li, Da-Yu; Xia, Ming-Liang; Hu, Li-Fa; Cao, Zhao-Liang; Mu, Quan-Quan; Xuan, Li
2014-09-01
With the help of adaptive optics (AO) technology, cellular level imaging of living human retina can be achieved. Aiming to reduce distressing feelings and to avoid potential drug induced diseases, we attempted to image retina with dilated pupil and froze accommodation without drugs. An optimized liquid crystal adaptive optics camera was adopted for retinal imaging. A novel eye stared system was used for stimulating accommodation and fixating imaging area. Illumination sources and imaging camera kept linkage for focusing and imaging different layers. Four subjects with diverse degree of myopia were imaged. Based on the optical properties of the human eye, the eye stared system reduced the defocus to less than the typical ocular depth of focus. In this way, the illumination light can be projected on certain retina layer precisely. Since that the defocus had been compensated by the eye stared system, the adopted 512 × 512 liquid crystal spatial light modulator (LC-SLM) corrector provided the crucial spatial fidelity to fully compensate high-order aberrations. The Strehl ratio of a subject with -8 diopter myopia was improved to 0.78, which was nearly close to diffraction-limited imaging. By finely adjusting the axial displacement of illumination sources and imaging camera, cone photoreceptors, blood vessels and nerve fiber layer were clearly imaged successfully.
Concepts in Light Microscopy of Viruses
Witte, Robert; Georgi, Fanny
2018-01-01
Viruses threaten humans, livestock, and plants, and are difficult to combat. Imaging of viruses by light microscopy is key to uncover the nature of known and emerging viruses in the quest for finding new ways to treat viral disease and deepening the understanding of virus–host interactions. Here, we provide an overview of recent technology for imaging cells and viruses by light microscopy, in particular fluorescence microscopy in static and live-cell modes. The review lays out guidelines for how novel fluorescent chemical probes and proteins can be used in light microscopy to illuminate cells, and how they can be used to study virus infections. We discuss advantages and opportunities of confocal and multi-photon microscopy, selective plane illumination microscopy, and super-resolution microscopy. We emphasize the prevalent concepts in image processing and data analyses, and provide an outlook into label-free digital holographic microscopy for virus research. PMID:29670029
Semiconductor lasers vs LEDs in diagnostic and therapeutic medicine
NASA Astrophysics Data System (ADS)
Gryko, Lukasz; Zajac, Andrzej; Szymanska, Justyna; Blaszczak, Urszula; Palkowska, Anna; Kulesza, Ewa
2016-12-01
Semiconductor emitters are used in many areas of medicine, allowing for new methods of diagnosis, treatment and effective prevention of many diseases. The article presents selected areas of application of semiconductor sources in UVVIS- NIR range, where in recent years competition in semiconductor lasers and LEDs applications has been observed. Examples of applications of analyzed sources are indicated for LLLT, PDT and optical diagnostics using the procedure of color contrast. Selected results of LLLT research of the authors are presented that were obtained by means of the developed optoelectronic system for objectified irradiation and studies on the impact of low-energy laser and LED on lines of endothelial cells of umbilical vein. Usefulness of the spectrally tunable LED lighting system for diagnostic purposes is also demonstrated, also as an illuminator for surface applications - in procedure of variable color contrast of the illuminated object.
Concepts in Light Microscopy of Viruses.
Witte, Robert; Andriasyan, Vardan; Georgi, Fanny; Yakimovich, Artur; Greber, Urs F
2018-04-18
Viruses threaten humans, livestock, and plants, and are difficult to combat. Imaging of viruses by light microscopy is key to uncover the nature of known and emerging viruses in the quest for finding new ways to treat viral disease and deepening the understanding of virus–host interactions. Here, we provide an overview of recent technology for imaging cells and viruses by light microscopy, in particular fluorescence microscopy in static and live-cell modes. The review lays out guidelines for how novel fluorescent chemical probes and proteins can be used in light microscopy to illuminate cells, and how they can be used to study virus infections. We discuss advantages and opportunities of confocal and multi-photon microscopy, selective plane illumination microscopy, and super-resolution microscopy. We emphasize the prevalent concepts in image processing and data analyses, and provide an outlook into label-free digital holographic microscopy for virus research.
Topology-aware illumination design for volume rendering.
Zhou, Jianlong; Wang, Xiuying; Cui, Hui; Gong, Peng; Miao, Xianglin; Miao, Yalin; Xiao, Chun; Chen, Fang; Feng, Dagan
2016-08-19
Direct volume rendering is one of flexible and effective approaches to inspect large volumetric data such as medical and biological images. In conventional volume rendering, it is often time consuming to set up a meaningful illumination environment. Moreover, conventional illumination approaches usually assign same values of variables of an illumination model to different structures manually and thus neglect the important illumination variations due to structure differences. We introduce a novel illumination design paradigm for volume rendering on the basis of topology to automate illumination parameter definitions meaningfully. The topological features are extracted from the contour tree of an input volumetric data. The automation of illumination design is achieved based on four aspects of attenuation, distance, saliency, and contrast perception. To better distinguish structures and maximize illuminance perception differences of structures, a two-phase topology-aware illuminance perception contrast model is proposed based on the psychological concept of Just-Noticeable-Difference. The proposed approach allows meaningful and efficient automatic generations of illumination in volume rendering. Our results showed that our approach is more effective in depth and shape depiction, as well as providing higher perceptual differences between structures.
Belova, L V; Mishkich, I A; Kresova, G A; Liubomudrova, T A
1999-03-01
Assessment of harmful industrial factors caused by work conditions in a modern milk processing plant. Work conditions, rest, nutrition, medical service, and subjective health indices among the employees in a new milk processing plant were studied. We used a specially formed questionnaire; instrumental measurements of microclimate parameters, noise, and illumination at workplace; laboratory physical and chemical evaluation of air pollution with aerosols and gases in the plant premises; chronometric studies determining the workers' activity during the working day location, and physical and psychological body exertion at the time of industrial activities; and assessment of design and operating documents of the plant. Laboratory studies included 157 workers, 1,724 tests, 26 chronometric studies, and analysis of 11 plant's documents. Unfavorable microclimatic conditions, noise, inadequate illumination, air pollution with dust and toxic substances, physical workload, increased demand for concentration, and monotony of labor in mass production professions were found. A great proportion of workers was dissatisfied with their working conditions and many suffered from occupational diseases and work-related diseases. The conditions of work in the studied milk processing plant may be classified as harmful and dangerous. The flaws in technological process, omissions in design and construction of the plant, as well as its improper exploitation aggravated industrial harmful factors. In combination with unsatisfactory organization of rest, nutrition, and medical services in the plant these factors may affect the workers' health and cause general and occupational diseases.
Synchrotron-based EUV lithography illuminator simulator
Naulleau, Patrick P.
2004-07-27
A lithographic illuminator to illuminate a reticle to be imaged with a range of angles is provided. The illumination can be employed to generate a pattern in the pupil of the imaging system, where spatial coordinates in the pupil plane correspond to illumination angles in the reticle plane. In particular, a coherent synchrotron beamline is used along with a potentially decoherentizing holographic optical element (HOE), as an experimental EUV illuminator simulation station. The pupil fill is completely defined by a single HOE, thus the system can be easily modified to model a variety of illuminator fill patterns. The HOE can be designed to generate any desired angular spectrum and such a device can serve as the basis for an illuminator simulator.
Bessel light sheet structured illumination microscopy
NASA Astrophysics Data System (ADS)
Noshirvani Allahabadi, Golchehr
Biomedical study researchers using animals to model disease and treatment need fast, deep, noninvasive, and inexpensive multi-channel imaging methods. Traditional fluorescence microscopy meets those criteria to an extent. Specifically, two-photon and confocal microscopy, the two most commonly used methods, are limited in penetration depth, cost, resolution, and field of view. In addition, two-photon microscopy has limited ability in multi-channel imaging. Light sheet microscopy, a fast developing 3D fluorescence imaging method, offers attractive advantages over traditional two-photon and confocal microscopy. Light sheet microscopy is much more applicable for in vivo 3D time-lapsed imaging, owing to its selective illumination of tissue layer, superior speed, low light exposure, high penetration depth, and low levels of photobleaching. However, standard light sheet microscopy using Gaussian beam excitation has two main disadvantages: 1) the field of view (FOV) of light sheet microscopy is limited by the depth of focus of the Gaussian beam. 2) Light-sheet images can be degraded by scattering, which limits the penetration of the excitation beam and blurs emission images in deep tissue layers. While two-sided sheet illumination, which doubles the field of view by illuminating the sample from opposite sides, offers a potential solution, the technique adds complexity and cost to the imaging system. We investigate a new technique to address these limitations: Bessel light sheet microscopy in combination with incoherent nonlinear Structured Illumination Microscopy (SIM). Results demonstrate that, at visible wavelengths, Bessel excitation penetrates up to 250 microns deep in the scattering media with single-side illumination. Bessel light sheet microscope achieves confocal level resolution at a lateral resolution of 0.3 micron and an axial resolution of 1 micron. Incoherent nonlinear SIM further reduces the diffused background in Bessel light sheet images, resulting in confocal quality images in thick tissue. The technique was applied to live transgenic zebra fish tg(kdrl:GFP), and the sub-cellular structure of fish vasculature genetically labeled with GFP was captured in 3D. The superior speed of the microscope enables us to acquire signal from 200 layers of a thick sample in 4 minutes. The compact microscope uses exclusively off-the-shelf components and offers a low-cost imaging solution for studying small animal models or tissue samples.
Seo, Hyejin; Nam, Dong Heun; Lee, Jong Yeon; Park, Su Jin; Kim, Yu Jeong; Kim, Seong-Woo; Chung, Tae-Young; Inoue, Makoto; Kim, Terry
2018-02-01
To evaluate macular photostress and visual experience between coaxial microscope illumination versus oblique intracameral illumination during cataract surgery. Gachon University Gil Hospital, Incheon, South Korea. Prospective case series. Consecutive patients who had cataract surgery using microscope illumination and intracameral illumination were included. The patients were asked to complete a questionnaire (seeing strong lights, feeling photophobia, feeling startled (fright) when seeing lights, seeing any colors, seeing any instruments or surgical procedures, and estimating intraoperative visual function) designed to describe their cataract surgery experience. The images projected on the retina of the model eye (rear view) with artificial opaque fragments in the anterior chamber during simulating cataract surgery were compared between the 2 illumination types. Sixty patients completed the questionnaire. Scores for strong lights, photophobia, fright, and color perception were significantly higher with microscope illumination than with intracameral illumination (all P < .001). More patients preferred the intracameral illumination (45 [75.0%]) to the microscope illumination (13 [21.7%]). In the rear-view images created in a model eye, only the bright microscope light in the center was seen without any lens image in the microscope illumination. However, in the intracameral illumination, the less bright light from the light pipe in the periphery and the lens fragments were seen more clearly. In a view of the patients' visual experience, oblique intracameral illumination caused less subjective photostress and was preferred over coaxial microscope illumination. Objective findings from the model-eye experiment correlated to the result of visual experience. Copyright © 2018 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Sindhu, Annu; Arora, Pooja; Chaudhury, Ashok
2012-07-01
A novel laboratory revolution for disease therapy, the RNA interference (RNAi) technology, has adopted a new era of molecular research as the next generation "Gene-targeted prophylaxis." In this review, we have focused on the chief technological challenges associated with the efforts to develop RNAi-based therapeutics that may guide the biomedical researchers. Many non-curable maladies, like neurodegenerative diseases and cancers have effectively been cured using this technology. Rapid advances are still in progress for the development of RNAi-based technologies that will be having a major impact on medical research. We have highlighted the recent discoveries associated with the phenomenon of RNAi, expression of silencing molecules in mammals along with the vector systems used for disease therapeutics.
Electrohydrodynamically patterned colloidal crystals
NASA Technical Reports Server (NTRS)
Hayward, Ryan C. (Inventor); Poon, Hak F. (Inventor); Xiao, Yi (Inventor); Saville, Dudley A. (Inventor); Aksay, Ilhan A. (Inventor)
2003-01-01
A method for assembling patterned crystalline arrays of colloidal particles using ultraviolet illumination of an optically-sensitive semiconducting anode while using the anode to apply an electronic field to the colloidal particles. The ultraviolet illumination increases current density, and consequently, the flow of the colloidal particles. As a result, colloidal particles can be caused to migrate from non-illuminated areas of the anode to illuminated areas of the anode. Selective illumination of the anode can also be used to permanently affix colloidal crystals to illuminated areas of the anode while not affixing them to non-illuminated areas of the anode.
Pupillary efficient lighting system
Berman, Samuel M.; Jewett, Don L.
1991-01-01
A lighting system having at least two independent lighting subsystems each with a different ratio of scotopic illumination to photopic illumination. The radiant energy in the visible region of the spectrum of the lighting subsystems can be adjusted relative to each other so that the total scotopic illumination of the combined system and the total photopic illumination of the combined system can be varied independently. The dilation or contraction of the pupil of an eye is controlled by the level of scotopic illumination and because the scotopic and photopic illumination can be separately controlled, the system allows the pupil size to be varied independently of the level of photopic illumination. Hence, the vision process can be improved for a given level of photopic illumination.
Azlan, C A; Ng, K H; Anandan, S; Nizam, M S
2006-09-01
Illuminance level in the softcopy image viewing room is a very important factor to optimize productivity in radiological diagnosis. In today's radiological environment, the illuminance measurements are normally done during the quality control procedure and performed annually. Although the room is equipped with dimmer switches, radiologists are not able to decide the level of illuminance according to the standards. The aim of this study is to develop a simple real-time illuminance detector system to assist the radiologists in deciding an adequate illuminance level during radiological image viewing. The system indicates illuminance in a very simple visual form by using light emitting diodes. By employing the device in the viewing room, illuminance level can be monitored and adjusted effectively.
Pearce, Bradley; Crichton, Stuart; Mackiewicz, Michal; Finlayson, Graham D; Hurlbert, Anya
2014-01-01
The phenomenon of colour constancy in human visual perception keeps surface colours constant, despite changes in their reflected light due to changing illumination. Although colour constancy has evolved under a constrained subset of illuminations, it is unknown whether its underlying mechanisms, thought to involve multiple components from retina to cortex, are optimised for particular environmental variations. Here we demonstrate a new method for investigating colour constancy using illumination matching in real scenes which, unlike previous methods using surface matching and simulated scenes, allows testing of multiple, real illuminations. We use real scenes consisting of solid familiar or unfamiliar objects against uniform or variegated backgrounds and compare discrimination performance for typical illuminations from the daylight chromaticity locus (approximately blue-yellow) and atypical spectra from an orthogonal locus (approximately red-green, at correlated colour temperature 6700 K), all produced in real time by a 10-channel LED illuminator. We find that discrimination of illumination changes is poorer along the daylight locus than the atypical locus, and is poorest particularly for bluer illumination changes, demonstrating conversely that surface colour constancy is best for blue daylight illuminations. Illumination discrimination is also enhanced, and therefore colour constancy diminished, for uniform backgrounds, irrespective of the object type. These results are not explained by statistical properties of the scene signal changes at the retinal level. We conclude that high-level mechanisms of colour constancy are biased for the blue daylight illuminations and variegated backgrounds to which the human visual system has typically been exposed.
"When pirates feast … who pays?" condoms, advertising, and the visibility paradox, 1920s and 1930s.
Treichler, Paula A
2014-12-01
For most of the 20th century, the condom in the United States was a cheap, useful, but largely unmentionable product. Federal and state statutes prohibited the advertising and open display of condoms, their distribution by mail and across state lines, and their sale for the purpose of birth control; in some states, even owning or using condoms was illegal. By the end of World War I, condoms were increasingly acceptable for the prevention of sexually transmitted disease, but their unique dual function--for disease prevention and contraception--created ongoing ambiguities for sellers, consumers, and distributors as well as for legal, political, health, and moral leaders. Not until the 1970s did condoms emerge from the shadows and join other personal hygiene products on open drugstore and supermarket shelves and in national advertisements. Then came the 1980s and AIDS when, despite the rise of Ronald Reagan, the radical right's demonization of condoms, and the initial reluctance of condom merchants to market to gay constituencies, the HIV/AIDS epidemic slowly but inexorably propelled the condom to the top of the prevention agenda. The condom's journey from lewd device to global superstar was fitful, but colorful. The Comstock Act of 1873, prohibiting birth control information and devices, created a vast underground operation--periodically illuminated, however, by arrests, protests, legal proceedings, and media coverage. This essay chronicles one such moment of illumination: the legal battle in the 1920s and 1930s over the legitimacy and legality of the Trojan Brand condom trademark and the unusual series of advertisements produced by the Youngs Rubber Corporation, makers of Trojans, to dramatize the ethical and economic issues of the trademark battle. Culminating in Youngs Rubber Corporation v. C.I. Lee & Co., Inc. (45 F, U.S. Court of Appeals for the Second Circuit 103 [1930]), this landmark case in trademark law established the right of the Trojan Brand condom, despite its ambiguous dual function, to the protection of a federal trademark. I seek to show how the Youngs antipiracy ad series illuminates the paradox of visibility by illuminating the paradox of any binary division: to establish the one depends inevitably on invoking or making visible--even if to suppress--the other. This essay is a case study in the negotiation of such a dialectic.
Shrestha, Ravi; Mohammed, Shahed K; Hasan, Md Mehedi; Zhang, Xuechao; Wahid, Khan A
2016-08-01
Wireless capsule endoscopy (WCE) plays an important role in the diagnosis of gastrointestinal (GI) diseases by capturing images of human small intestine. Accurate diagnosis of endoscopic images depends heavily on the quality of captured images. Along with image and frame rate, brightness of the image is an important parameter that influences the image quality which leads to the design of an efficient illumination system. Such design involves the choice and placement of proper light source and its ability to illuminate GI surface with proper brightness. Light emitting diodes (LEDs) are normally used as sources where modulated pulses are used to control LED's brightness. In practice, instances like under- and over-illumination are very common in WCE, where the former provides dark images and the later provides bright images with high power consumption. In this paper, we propose a low-power and efficient illumination system that is based on an automated brightness algorithm. The scheme is adaptive in nature, i.e., the brightness level is controlled automatically in real-time while the images are being captured. The captured images are segmented into four equal regions and the brightness level of each region is calculated. Then an adaptive sigmoid function is used to find the optimized brightness level and accordingly a new value of duty cycle of the modulated pulse is generated to capture future images. The algorithm is fully implemented in a capsule prototype and tested with endoscopic images. Commercial capsules like Pillcam and Mirocam were also used in the experiment. The results show that the proposed algorithm works well in controlling the brightness level accordingly to the environmental condition, and as a result, good quality images are captured with an average of 40% brightness level that saves power consumption of the capsule.
In vivo dark-field imaging of the retinal pigment epithelium cell mosaic
Scoles, Drew; Sulai, Yusufu N.; Dubra, Alfredo
2013-01-01
Non-invasive reflectance imaging of the human RPE cell mosaic is demonstrated using a modified confocal adaptive optics scanning light ophthalmoscope (AOSLO). The confocal circular aperture in front of the imaging detector was replaced with a combination of a circular aperture 4 to 16 Airy disks in diameter and an opaque filament, 1 or 3 Airy disks thick. This arrangement reveals the RPE cell mosaic by dramatically attenuating the light backscattered by the photoreceptors. The RPE cell mosaic was visualized in all 7 recruited subjects at multiple retinal locations with varying degrees of contrast and cross-talk from the photoreceptors. Various experimental settings were explored for improving the visualization of the RPE cell boundaries including: pinhole diameter, filament thickness, illumination and imaging pupil apodization, unmatched imaging and illumination focus, wavelength and polarization. None of these offered an obvious path for enhancing image contrast. The demonstrated implementation of dark-field AOSLO imaging using 790 nm light requires low light exposures relative to light safety standards and it is more comfortable for the subject than the traditional autofluorescence RPE imaging with visible light. Both these factors make RPE dark-field imaging appealing for studying mechanisms of eye disease, as well as a clinical tool for screening and monitoring disease progression. PMID:24049692
Lee, Alex C H; Elson, Daniel S; Neil, Mark A; Kumar, Sunil; Ling, Bingo W; Bello, Fernando; Hanna, George B
2009-03-01
Current arc-lamp illumination systems have a number of technical and ergonomic limitations. White light-emitting diodes (LEDs) are energy-efficient solid-state lighting devices which are small, durable and inexpensive. Their use as an alternative to arc-lamp light sources in minimal access surgery has not been explored. This study aims to develop an LED-based endo-illuminator and to determine its lighting characteristics for use in minimal access surgery. We developed an LED endo-illuminator using a white LED mounted at the tip of a steel rod. Offline image analysis was carried out to compare the illuminated field using the LED endo-illuminator or an arc-lamp based endoscope in terms of uniformity, shadow sharpness and overall image intensity. Direct radiometric power measurements in light intensity and stability were obtained. Visual perception of fine details at the peripheral endoscopic field was assessed by 13 subjects using the different illumination systems. Illumination from the LED endo-illuminator was more uniform compared to illumination from an arc-lamp source, especially at the closer distance of 4 cm (0.0006 versus 0.0028 arbitrary units--lower value indicates more uniform illumination). The shadows were also sharper (edge widths of 16 versus 44 pixels for the first edge and 15 versus 61 pixels for the second edge). The overall mean image intensity was higher (127 versus 100 arbitrary units) when using the autoshutter mode despite the lower direct radiometric power, about one tenth of the arc-lamp endoscopic system. The illumination was also more stable with less flickering (0.02% versus 5% of total power in non-DC components). Higher median scores on visual perception was also obtained (237 versus 157, p < 0.001). The LED endo-illuminator provides more uniform illumination with sharper shadows, less flickering and better illumination for visual perception than the arc-lamp-based system currently used.
NASA Astrophysics Data System (ADS)
Toadere, Florin
2017-12-01
A spectral image processing algorithm that allows the illumination of the scene with different illuminants together with the reconstruction of the scene's reflectance is presented. Color checker spectral image and CIE A (warm light 2700 K), D65 (cold light 6500 K) and Cree TW Series LED T8 (4000 K) are employed for scene illumination. Illuminants used in the simulations have different spectra and, as a result of their illumination, the colors of the scene change. The influence of the illuminants on the reconstruction of the scene's reflectance is estimated. Demonstrative images and reflectance showing the operation of the algorithm are illustrated.
Pearce, Bradley; Crichton, Stuart; Mackiewicz, Michal; Finlayson, Graham D.; Hurlbert, Anya
2014-01-01
The phenomenon of colour constancy in human visual perception keeps surface colours constant, despite changes in their reflected light due to changing illumination. Although colour constancy has evolved under a constrained subset of illuminations, it is unknown whether its underlying mechanisms, thought to involve multiple components from retina to cortex, are optimised for particular environmental variations. Here we demonstrate a new method for investigating colour constancy using illumination matching in real scenes which, unlike previous methods using surface matching and simulated scenes, allows testing of multiple, real illuminations. We use real scenes consisting of solid familiar or unfamiliar objects against uniform or variegated backgrounds and compare discrimination performance for typical illuminations from the daylight chromaticity locus (approximately blue-yellow) and atypical spectra from an orthogonal locus (approximately red-green, at correlated colour temperature 6700 K), all produced in real time by a 10-channel LED illuminator. We find that discrimination of illumination changes is poorer along the daylight locus than the atypical locus, and is poorest particularly for bluer illumination changes, demonstrating conversely that surface colour constancy is best for blue daylight illuminations. Illumination discrimination is also enhanced, and therefore colour constancy diminished, for uniform backgrounds, irrespective of the object type. These results are not explained by statistical properties of the scene signal changes at the retinal level. We conclude that high-level mechanisms of colour constancy are biased for the blue daylight illuminations and variegated backgrounds to which the human visual system has typically been exposed. PMID:24586299
Black light - How sensors filter spectral variation of the illuminant
NASA Technical Reports Server (NTRS)
Brainard, David H.; Wandell, Brian A.; Cowan, William B.
1989-01-01
Visual sensor responses may be used to classify objects on the basis of their surface reflectance functions. In a color image, the image data are represented as a vector of sensor responses at each point in the image. This vector depends both on the surface reflectance functions and on the spectral power distribution of the ambient illumination. Algorithms designed to classify objects on the basis of their surface reflectance functions typically attempt to overcome the dependence of the sensor responses on the illuminant by integrating sensor data collected from multiple surfaces. In machine vision applications, it is shown that it is often possible to design the sensor spectral responsivities so that the vector direction of the sensor responses does not depend upon the illuminant. The conditions under which this is possible are given and an illustrative calculation is performed. In biological systems, where the sensor responsivities are fixed, it is shown that some changes in the illumination cause no change in the sensor responses. Such changes in illuminant are called black illuminants. It is possible to express any illuminant as the sum of two unique components. One component is a black illuminant. The second component is called the visible component. The visible component of an illuminant completely characterizes the effect of the illuminant on the vector of sensor responses.
Internal-illumination photoacoustic computed tomography
NASA Astrophysics Data System (ADS)
Li, Mucong; Lan, Bangxin; Liu, Wei; Xia, Jun; Yao, Junjie
2018-03-01
We report a photoacoustic computed tomography (PACT) system using a customized optical fiber with a cylindrical diffuser to internally illuminate deep targets. The traditional external light illumination in PACT usually limits the penetration depth to a few centimeters from the tissue surface, mainly due to strong optical attenuation along the light propagation path from the outside in. By contrast, internal light illumination, with external ultrasound detection, can potentially detect much deeper targets. Different from previous internal illumination PACT implementations using forward-looking optical fibers, our internal-illumination PACT system uses a customized optical fiber with a 3-cm-long conoid needle diffuser attached to the fiber tip, which can homogeneously illuminate the surrounding space and substantially enlarge the field of view. We characterized the internal illumination distribution and PACT system performance. We performed tissue phantom and in vivo animal studies to further demonstrate the superior imaging depth using internal illumination over external illumination. We imaged a 7.5-cm-deep leaf target embedded in optically scattering medium and the beating heart of a mouse overlaid with 3.7-cm-thick chicken tissue. Our results have collectively demonstrated that the internal light illumination combined with external ultrasound detection might be a useful strategy to improve the penetration depth of PACT in imaging deep organs of large animals and humans.
Large Volume, Behaviorally-relevant Illumination for Optogenetics in Non-human Primates.
Acker, Leah C; Pino, Erica N; Boyden, Edward S; Desimone, Robert
2017-10-03
This protocol describes a large-volume illuminator, which was developed for optogenetic manipulations in the non-human primate brain. The illuminator is a modified plastic optical fiber with etched tip, such that the light emitting surface area is > 100x that of a conventional fiber. In addition to describing the construction of the large-volume illuminator, this protocol details the quality-control calibration used to ensure even light distribution. Further, this protocol describes techniques for inserting and removing the large volume illuminator. Both superficial and deep structures may be illuminated. This large volume illuminator does not need to be physically coupled to an electrode, and because the illuminator is made of plastic, not glass, it will simply bend in circumstances when traditional optical fibers would shatter. Because this illuminator delivers light over behaviorally-relevant tissue volumes (≈ 10 mm 3 ) with no greater penetration damage than a conventional optical fiber, it facilitates behavioral studies using optogenetics in non-human primates.
Illumination estimation via thin-plate spline interpolation.
Shi, Lilong; Xiong, Weihua; Funt, Brian
2011-05-01
Thin-plate spline interpolation is used to interpolate the chromaticity of the color of the incident scene illumination across a training set of images. Given the image of a scene under unknown illumination, the chromaticity of the scene illumination can be found from the interpolated function. The resulting illumination-estimation method can be used to provide color constancy under changing illumination conditions and automatic white balancing for digital cameras. A thin-plate spline interpolates over a nonuniformly sampled input space, which in this case is a training set of image thumbnails and associated illumination chromaticities. To reduce the size of the training set, incremental k medians are applied. Tests on real images demonstrate that the thin-plate spline method can estimate the color of the incident illumination quite accurately, and the proposed training set pruning significantly decreases the computation.
NASA Astrophysics Data System (ADS)
Amelard, Robert; Scharfenberger, Christian; Wong, Alexander; Clausi, David A.
2015-03-01
Non-contact camera-based imaging photoplethysmography (iPPG) is useful for measuring heart rate in conditions where contact devices are problematic due to issues such as mobility, comfort, and sanitation. Existing iPPG methods analyse the light-tissue interaction of either active or passive (ambient) illumination. Many active iPPG methods assume the incident ambient light is negligible to the active illumination, resulting in high power requirements, while many passive iPPG methods assume near-constant ambient conditions. These assumptions can only be achieved in environments with controlled illumination and thus constrain the use of such devices. To increase the number of possible applications of iPPG devices, we propose a dual-mode active iPPG system that is robust to changes in ambient illumination variations. Our system uses a temporally-coded illumination sequence that is synchronized with the camera to measure both active and ambient illumination interaction for determining heart rate. By subtracting the ambient contribution, the remaining illumination data can be attributed to the controlled illuminant. Our device comprises a camera and an LED illuminant controlled by a microcontroller. The microcontroller drives the temporal code via synchronizing the frame captures and illumination time at the hardware level. By simulating changes in ambient light conditions, experimental results show our device is able to assess heart rate accurately in challenging lighting conditions. By varying the temporal code, we demonstrate the trade-off between camera frame rate and ambient light compensation for optimal blood pulse detection.
Looking inside the heart: a see-through view of the vascular tree
Nehrhoff, Imke; Ripoll, Jorge; Samaniego, Rafael; Desco, Manuel; Gómez-Gaviro, Maria Victoria
2017-01-01
The ability to acquire 3D images of the heart and its vasculature at cellular resolution facilitates a more detailed study of many heart diseases. Here, we describe a novel technique to image in 3D the heart vasculature by combining the CUBIC clearing protocol combined with in vivo administration of fluorescent-labeled lectin. The use of these techniques in combination with Selective Plane Illumination Microscopy (SPIM) made it possible to obtain high resolution 3D images of the cardiac vascular tree. This methodological approach may enhance the visualization of 3D images of the cardiac vasculature remodeling associated with coronary disease. PMID:28663930
Biological Effects Of Full-Spectrum Lighting
NASA Astrophysics Data System (ADS)
Bickford, Elwood D.
1980-10-01
Humans and other living organisms have evolved various known and unknown photoreceptors and responses under full-spectrum optical radiation of sun and sky at the earth's surface. The trend to indoor living over the past 100 years has produced a self-exile from this radiation environment resulting in the disease conditions of rickets and erythema. Concerns for these diseases have pointed attention to the delicate balance between the beneficial and detrimental effects of full-spectrum optical radiation and has confounded the concepts of illumination and radiation safety criteria. Further knowledge has to be obtained to better evaluate the known and unknown effects of full-spectrum optical radiation in a modern society.
Effect of Illumination on Ocular Status Modifications Induced by Short-Term 3D TV Viewing
Chen, Yuanyuan; Xu, Aiqin; Jiang, Jian
2017-01-01
Objectives. This study aimed to compare changes in ocular status after 3D TV viewing under three modes of illumination and thereby identify optimal illumination for 3D TV viewing. Methods. The following measures of ocular status were assessed: the accommodative response, accommodative microfluctuation, accommodative facility, relative accommodation, gradient accommodative convergence/accommodation (AC/A) ratio, phoria, and fusional vergence. The observers watched 3D television for 90 minutes through 3D shutter glasses under three illumination modes: A, complete darkness; B, back illumination (50 lx); and C, front illumination (130 lx). The ocular status of the observers was assessed both before and after the viewing. Results. After 3D TV viewing, the accommodative response and accommodative microfluctuation were significantly changed under illumination Modes A and B. The near positive fusional vergence decreased significantly after the 90-minute 3D viewing session under each illumination mode, and this effect was not significantly different among the three modes. Conclusions. Short-term 3D viewing modified the ocular status of adults. The least amount of such change occurred with front illumination, suggesting that this type of illumination is an appropriate mode for 3D shutter TV viewing. PMID:28348893
The relationship between ambient illumination and psychological factors in viewing of display Images
NASA Astrophysics Data System (ADS)
Iwanami, Takuya; Kikuchi, Ayano; Kaneko, Takashi; Hirai, Keita; Yano, Natsumi; Nakaguchi, Toshiya; Tsumura, Norimichi; Yoshida, Yasuhiro; Miyake, Yoichi
2009-01-01
In this paper, we have clarified the relationship between ambient illumination and psychological factors in viewing of display images. Psychological factors were obtained by the factor analysis with the results of the semantic differential (SD) method. In the psychological experiments, subjects evaluated the impressions of displayed images with changing ambient illuminating conditions. The illumination conditions were controlled by a fluorescent ceiling light and a color LED illumination which was located behind the display. We experimented under two kinds of conditions. One was the experiment with changing brightness of the ambient illumination. The other was the experiment with changing the colors of the background illumination. In the results of the experiment, two factors "realistic sensation, dynamism" and "comfortable," were extracted under different brightness of the ambient illumination of the display surroundings. It was shown that the "comfortable" was improved by the brightness of display surroundings. On the other hand, when the illumination color of surroundings was changed, three factors "comfortable," "realistic sensation, dynamism" and "activity" were extracted. It was also shown that the value of "comfortable" and "realistic sensation, dynamism" increased when the display surroundings were illuminated by the average color of the image contents.
Optimal color temperature adjustment for mobile devices under varying illuminants
NASA Astrophysics Data System (ADS)
Choi, Kyungah; Suk, Hyeon-Jeong
2014-01-01
With the wide use of mobile devices, display color reproduction has become extremely important. The purpose of this study is to investigate the optimal color temperature for mobile displays under varying illuminants. The effect of the color temperature and the illuminance of ambient lighting on user preferences were observed. For a visual examination, a total of 19 nuanced whites were examined under 20 illuminants. A total of 19 display stimuli with different color temperatures (2,500 K ~ 19,600 K) were presented on an iPad3 (New iPad). The ambient illuminants ranged in color temperature from 2,500 K to 19,800 K and from 0 lx to 3,000 lx in illuminance. Supporting previous studies of color reproduction, there was found to be a positive correlation between the color temperature of illuminants and that of optimal whites. However, the relationship was not linear. Based on assessments by 56 subjects, a regression equation was derived to predict the optimal color temperature adjustment under varying illuminants, as follows: [Display Tcp = 5138.93 log(Illuminant Tcp) - 11956.59, p<.001, R2=0.94]. Moreover, the influence of an illuminant was positively correlated with the illuminance level, confirming the findings of previous studies. It is expected that the findings of this study can be used as the theoretical basis when designing a color strategy for mobile display devices.
Diffraction analysis of customized illumination technique
NASA Astrophysics Data System (ADS)
Lim, Chang-Moon; Kim, Seo-Min; Eom, Tae-Seung; Moon, Seung Chan; Shin, Ki S.
2004-05-01
Various enhancement techniques such as alternating PSM, chrome-less phase lithography, double exposure, etc. have been considered as driving forces to lead the production k1 factor towards below 0.35. Among them, a layer specific optimization of illumination mode, so-called customized illumination technique receives deep attentions from lithographers recently. A new approach for illumination customization based on diffraction spectrum analysis is suggested in this paper. Illumination pupil is divided into various diffraction domains by comparing the similarity of the confined diffraction spectrum. Singular imaging property of individual diffraction domain makes it easier to build and understand the customized illumination shape. By comparing the goodness of image in each domain, it was possible to achieve the customized shape of illumination. With the help from this technique, it was found that the layout change would not gives the change in the shape of customized illumination mode.
User-preferred color temperature adjustment for smartphone display under varying illuminants
NASA Astrophysics Data System (ADS)
Choi, Kyungah; Suk, Hyeon-Jeong
2014-06-01
The study aims to investigate the user-preferred color temperature adjustment for smartphone displays by observing the effect of the illuminant's chromaticity and intensity on the optimal white points preferred by users. For visual examination, subjects evaluated 14 display stimuli presented on the Samsung Galaxy S3 under 19 ambient illuminants. The display stimuli were composed of 14 nuanced whites varying in color temperature from 2900 to 18,900 K. The illuminant conditions varied with combinations of color temperature (2600 to 20,100 K) and illuminance level (30 to 3100 lx) that simulated daily lighting experiences. The subjects were asked to assess the optimal level of the display color temperatures based on their mental representation of the ideal white point. The study observed a positive correlation between the illuminant color temperatures and the optimal display color temperatures (r=0.89, p<0.05). However, the range of the color temperature of the smartphone display was much narrower than that of the illuminants. Based on the assessments by 100 subjects, a regression formula was derived to predict the adjustment of user-preferred color temperature under changing illuminant chromaticity. The formula is as follows: [Display Tcp=6534.75 log (Illuminant Tcp)-16304.68 (R=0.87, p<0.05)]. Moreover, supporting previous studies on color reproduction, the effect of illuminant chromaticity was relatively weaker under lower illuminance. The results of this experiment could be used as a theoretical basis for designers and manufacturers to adjust user-preferred color temperature for smartphone displays under various illuminant conditions.
Lightness of an object under two illumination levels.
Zdravković, Suncica; Economou, Elias; Gilchrist, Alan
2006-01-01
Anchoring theory (Gilchrist et al, 1999 Psychological Review 106 795-834) predicts a wide range of lightness errors, including failures of constancy in multi-illumination scenes and a long list of well-known lightness illusions seen under homogeneous illumination. Lightness values are computed both locally and globally and then averaged together. Local values are computed within a given region of homogeneous illumination. Thus, for an object that extends through two different illumination levels, anchoring theory produces two values, one for the patch in brighter illumination and one for the patch in dimmer illumination. Observers can give matches for these patches separately, but they can also give a single match for the whole object. Anchoring theory in its current form is unable to predict these object matches. We report eight experiments in which we studied the relationship between patch matches and object matches. The results show that the object match represents a compromise between the match for the patch in the field of highest illumination and the patch in the largest field of illumination. These two principles are parallel to the rules found for anchoring lightness: highest luminance rule and area rule.
Micro-optics: enabling technology for illumination shaping in optical lithography
NASA Astrophysics Data System (ADS)
Voelkel, Reinhard
2014-03-01
Optical lithography has been the engine that has empowered semiconductor industry to continually reduce the half-pitch for over 50 years. In early mask aligners a simple movie lamp was enough to illuminate the photomask. Illumination started to play a more decisive role when proximity mask aligners appeared in the mid-1970s. Off-axis illumination was introduced to reduce diffraction effects. For early projection lithography systems (wafer steppers), the only challenge was to collect the light efficiently to ensure short exposure time. When projection optics reached highest level of perfection, further improvement was achieved by optimizing illumination. Shaping the illumination light, also referred as pupil shaping, allows the optical path from reticle to wafer to be optimized and thus has a major impact on aberrations and diffraction effects. Highly-efficient micro-optical components are perfectly suited for this task. Micro-optics for illumination evolved from simple flat-top (fly's-eye) to annular, dipole, quadrupole, multipole and freeform illumination. Today, programmable micro-mirror arrays allow illumination to be changed on the fly. The impact of refractive, diffractive and reflective microoptics for photolithography will be discussed.
Determinants of Colour Constancy and the Blue Bias
Gegenfurtner, Karl
2017-01-01
We investigated several sensory and cognitive determinants of colour constancy across 40 illumination hues. In the first experiment, we measured colour naming for the illumination and for the colour induced by the illumination on the colorimetric grey. Results confirmed that the induced colours are approximately complementary to the colour of the illumination. In the second experiment, we measured colour constancy using achromatic adjustments. Average colour constancy was perfect under the blue daylight illumination and decreased in colour directions away from the blue daylight illumination due to undershooting and a strong blue bias. Apart from this blue bias, colour constancy was not related to illumination discrimination and to chromatic detection measured previously with the same setup and stimuli. We also observed a strong negative relationship between the degree of colour constancy and the consensus of naming the illumination colour. Constancy coincided with a low naming consensus, in particular because bluish illumination colours were sometimes seen as achromatic. Blue bias and category consensus alone explained >68%, and all determinants together explained >94% of the variance of achromatic adjustments. These findings suggest that colour constancy is optimised for blue daylight. PMID:29348910
Genome-scale approaches to the epigenetics of common human disease
2011-01-01
Traditionally, the pathology of human disease has been focused on microscopic examination of affected tissues, chemical and biochemical analysis of biopsy samples, other available samples of convenience, such as blood, and noninvasive or invasive imaging of varying complexity, in order to classify disease and illuminate its mechanistic basis. The molecular age has complemented this armamentarium with gene expression arrays and selective analysis of individual genes. However, we are entering a new era of epigenomic profiling, i.e., genome-scale analysis of cell-heritable nonsequence genetic change, such as DNA methylation. The epigenome offers access to stable measurements of cellular state and to biobanked material for large-scale epidemiological studies. Some of these genome-scale technologies are beginning to be applied to create the new field of epigenetic epidemiology. PMID:19844740
Adaptive non-local smoothing-based weberface for illumination-insensitive face recognition
NASA Astrophysics Data System (ADS)
Yao, Min; Zhu, Changming
2017-07-01
Compensating the illumination of a face image is an important process to achieve effective face recognition under severe illumination conditions. This paper present a novel illumination normalization method which specifically considers removing the illumination boundaries as well as reducing the regional illumination. We begin with the analysis of the commonly used reflectance model and then expatiate the hybrid usage of adaptive non-local smoothing and the local information coding based on Weber's law. The effectiveness and advantages of this combination are evidenced visually and experimentally. Results on Extended YaleB database show its better performance than several other famous methods.
Santos, Silvia; Chu, Kengyeh K; Lim, Daryl; Bozinovic, Nenad; Ford, Tim N; Hourtoule, Claire; Bartoo, Aaron C; Singh, Satish K; Mertz, Jerome
2009-01-01
We present an endomicroscope apparatus that exhibits out-of-focus background rejection based on wide-field illumination through a flexible imaging fiber bundle. Our technique, called HiLo microscopy, involves acquiring two images, one with grid-pattern illumination and another with standard uniform illumination. An evaluation of the image contrast with grid-pattern illumination provides an optically sectioned image with low resolution. This is complemented with high-resolution information from the uniform illumination image, leading to a full-resolution image that is optically sectioned. HiLo endomicroscope movies are presented of fluorescently labeled rat colonic mucosa.
NASA Astrophysics Data System (ADS)
Santos, Silvia; Chu, Kengyeh K.; Lim, Daryl; Bozinovic, Nenad; Ford, Tim N.; Hourtoule, Claire; Bartoo, Aaron C.; Singh, Satish K.; Mertz, Jerome
2009-05-01
We present an endomicroscope apparatus that exhibits out-of-focus background rejection based on wide-field illumination through a flexible imaging fiber bundle. Our technique, called HiLo microscopy, involves acquiring two images, one with grid-pattern illumination and another with standard uniform illumination. An evaluation of the image contrast with grid-pattern illumination provides an optically sectioned image with low resolution. This is complemented with high-resolution information from the uniform illumination image, leading to a full-resolution image that is optically sectioned. HiLo endomicroscope movies are presented of fluorescently labeled rat colonic mucosa.
Illumination discrimination in real and simulated scenes
Radonjić, Ana; Pearce, Bradley; Aston, Stacey; Krieger, Avery; Dubin, Hilary; Cottaris, Nicolas P.; Brainard, David H.; Hurlbert, Anya C.
2016-01-01
Characterizing humans' ability to discriminate changes in illumination provides information about the visual system's representation of the distal stimulus. We have previously shown that humans are able to discriminate illumination changes and that sensitivity to such changes depends on their chromatic direction. Probing illumination discrimination further would be facilitated by the use of computer-graphics simulations, which would, in practice, enable a wider range of stimulus manipulations. There is no a priori guarantee, however, that results obtained with simulated scenes generalize to real illuminated scenes. To investigate this question, we measured illumination discrimination in real and simulated scenes that were well-matched in mean chromaticity and scene geometry. Illumination discrimination thresholds were essentially identical for the two stimulus types. As in our previous work, these thresholds varied with illumination change direction. We exploited the flexibility offered by the use of graphics simulations to investigate whether the differences across direction are preserved when the surfaces in the scene are varied. We show that varying the scene's surface ensemble in a manner that also changes mean scene chromaticity modulates the relative sensitivity to illumination changes along different chromatic directions. Thus, any characterization of sensitivity to changes in illumination must be defined relative to the set of surfaces in the scene. PMID:28558392
An intraocular micro light-emitting diode device for endo-illumination during pars plana vitrectomy.
Koelbl, Philipp S; Lingenfelder, Christian; Spraul, Christoph W; Kampmeier, Juergen; Koch, Frank Hj; Kim, Yong Keun; Hessling, Martin
2018-03-01
Development of a new, fiber-free, single-use endo-illuminator for pars plana vitrectomy as a replacement for fiber-based systems with external light sources. The hand-guided intraocularly placed white micro light-emitting diode is evaluated for its illumination properties and potential photochemical and thermal hazards. A micro light-emitting diode was used to develop a single-use intraocular illumination system. The light-source-on-tip device was implemented in a prototype with 23G trocar compatible outer diameter of 0.6 mm. The experimental testing was performed on porcine eyes. All calculations of possible photochemical and thermal hazards during the application of the intraocular micro light-emitting diode were calculated according to DIN EN ISO 15007-2: 2014. The endo-illuminator generated a homogeneous and bright illumination of the intraocular space. The color impression was physiologic and natural. Contrary to initial apprehension, the possible risk caused by inserting a light-emitting diode into the intraocular vitreous was much smaller when compared to conventional fiber-based illumination systems. The photochemical and thermal hazards allowed a continuous exposure time to the retina of at least 4.7 h. This first intraocular light source showed that a light-emitting diode can be introduced into the eye. The system can be built as single-use illumination system. This light-source-on-tip light-emitting diode-endo-illumination combines a chandelier wide-angle illumination with an adjustable endo-illuminator.
Wide-field fundus imaging with trans-palpebral illumination.
Toslak, Devrim; Thapa, Damber; Chen, Yanjun; Erol, Muhammet Kazim; Paul Chan, R V; Yao, Xincheng
2017-01-28
In conventional fundus imaging devices, transpupillary illumination is used for illuminating the inside of the eye. In this method, the illumination light is directed into the posterior segment of the eye through the cornea and passes the pupillary area. As a result of sharing the pupillary area for the illumination beam and observation path, pupil dilation is typically necessary for wide-angle fundus examination, and the field of view is inherently limited. An alternative approach is to deliver light from the sclera. It is possible to image a wider retinal area with transcleral-illumination. However, the requirement of physical contact between the illumination probe and the sclera is a drawback of this method. We report here trans-palpebral illumination as a new method to deliver the light through the upper eyelid (palpebra). For this study, we used a 1.5 mm diameter fiber with a warm white LED light source. To illuminate the inside of the eye, the fiber illuminator was placed at the location corresponding to the pars plana region. A custom designed optical system was attached to a digital camera for retinal imaging. The optical system contained a 90 diopter ophthalmic lens and a 25 diopter relay lens. The ophthalmic lens collected light coming from the posterior of the eye and formed an aerial image between the ophthalmic and relay lenses. The aerial image was captured by the camera through the relay lens. An adequate illumination level was obtained to capture wide angle fundus images within ocular safety limits, defined by the ISO 15004-2: 2007 standard. This novel trans-palpebral illumination approach enables wide-angle fundus photography without eyeball contact and pupil dilation.
Photovoltaic Retinal Prosthesis with High Pixel Density
Mathieson, Keith; Loudin, James; Goetz, Georges; Huie, Philip; Wang, Lele; Kamins, Theodore I.; Galambos, Ludwig; Smith, Richard; Harris, James S.; Sher, Alexander; Palanker, Daniel
2012-01-01
Retinal degenerative diseases lead to blindness due to loss of the “image capturing” photoreceptors, while neurons in the “image processing” inner retinal layers are relatively well preserved. Electronic retinal prostheses seek to restore sight by electrically stimulating surviving neurons. Most implants are powered through inductive coils, requiring complex surgical methods to implant the coil-decoder-cable-array systems, which deliver energy to stimulating electrodes via intraocular cables. We present a photovoltaic subretinal prosthesis, in which silicon photodiodes in each pixel receive power and data directly through pulsed near-infrared illumination and electrically stimulate neurons. Stimulation was produced in normal and degenerate rat retinas, with pulse durations from 0.5 to 4 ms, and threshold peak irradiances from 0.2 to 10 mW/mm2, two orders of magnitude below the ocular safety limit. Neural responses were elicited by illuminating a single 70 μm bipolar pixel, demonstrating the possibility of a fully-integrated photovoltaic retinal prosthesis with high pixel density. PMID:23049619
NASA Astrophysics Data System (ADS)
Fei, Peng; Lee, Juhyun; Packard, René R. Sevag; Sereti, Konstantina-Ioanna; Xu, Hao; Ma, Jianguo; Ding, Yichen; Kang, Hanul; Chen, Harrison; Sung, Kevin; Kulkarni, Rajan; Ardehali, Reza; Kuo, C.-C. Jay; Xu, Xiaolei; Ho, Chih-Ming; Hsiai, Tzung K.
2016-03-01
Light Sheet Fluorescence Microscopy (LSFM) enables multi-dimensional and multi-scale imaging via illuminating specimens with a separate thin sheet of laser. It allows rapid plane illumination for reduced photo-damage and superior axial resolution and contrast. We hereby demonstrate cardiac LSFM (c-LSFM) imaging to assess the functional architecture of zebrafish embryos with a retrospective cardiac synchronization algorithm for four-dimensional reconstruction (3-D space + time). By combining our approach with tissue clearing techniques, we reveal the entire cardiac structures and hypertrabeculation of adult zebrafish hearts in response to doxorubicin treatment. By integrating the resolution enhancement technique with c-LSFM to increase the resolving power under a large field-of-view, we demonstrate the use of low power objective to resolve the entire architecture of large-scale neonatal mouse hearts, revealing the helical orientation of individual myocardial fibers. Therefore, our c-LSFM imaging approach provides multi-scale visualization of architecture and function to drive cardiovascular research with translational implication in congenital heart diseases.
Developing a Fluorescent Toolbox To Shed Light on the Mysteries of RNA.
Alexander, Seth C; Devaraj, Neal K
2017-10-03
Technologies that detect and image RNA have illuminated the complex roles played by RNA, redefining the traditional and superficial role first outlined by the central dogma of biology. Because there is such a wide diversity of RNA structure arising from an assortment of functions within biology, a toolbox of approaches have emerged for investigation of this important class of biomolecules. These methods are necessary to detect and elucidate the localization and dynamics of specific RNAs and in doing so unlock our understanding of how RNA dysregulation leads to disease. Current methods for detecting and imaging RNA include in situ hybridization techniques, fluorescent aptamers, RNA binding proteins fused to fluorescent reporters, and covalent labeling strategies. Because of the inherent diversity of these methods, each approach comes with a set of strengths and limitations that leave room for future improvement. This perspective seeks to highlight the most recent advances and remaining challenges for the wide-ranging toolbox of technologies that illuminate RNA's contribution to cellular complexity.
Steinbauer, Julia Maria; Schreml, Stephan; Babilas, Philipp; Zeman, Florian; Karrer, Sigrid; Landthaler, Michael; Szeimies, Rolf-Markus
2009-08-01
Photodynamic therapy (PDT) with aminolevulinic acid (ALA) or methyl aminolevulinate (MAL) is an approved modality for the non-invasive treatment of actinic keratoses (AK) and basal cell carcinoma (BCC) offering excellent cosmetic outcome. However, pain during and after illumination is the most frequent and limiting side effect. The aim of this study was to precisely assess how reported pain during PDT is influenced by sex, age, treatment site, disease (AK/BCC) as well as the photosensitizer used. 467 lesions consisting of AK (primary treatments: n=158; follow-up: n=47) or BCC (primary treatments: n=138; follow-up: 124) were treated by ALA- or MAL-PDT using metal halide lamps (580-750 nm). Pain was assessed during illumination using a continuous visual analogue scale (VAS). Factors predictive for higher pain levels during PDT are treatment of the head, treating AK and using ALA. The observed results may improve patient management and predict which level of pain to expect, and what kind of pain relief to prepare.
21 CFR 892.1890 - Radiographic film illuminator.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Radiographic film illuminator. 892.1890 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1890 Radiographic film illuminator. (a) Identification. A radiographic film illuminator is a device containing a visible light source covered with a...
21 CFR 892.1890 - Radiographic film illuminator.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Radiographic film illuminator. 892.1890 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1890 Radiographic film illuminator. (a) Identification. A radiographic film illuminator is a device containing a visible light source covered with a...
21 CFR 892.1890 - Radiographic film illuminator.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Radiographic film illuminator. 892.1890 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1890 Radiographic film illuminator. (a) Identification. A radiographic film illuminator is a device containing a visible light source covered with a...
21 CFR 892.1890 - Radiographic film illuminator.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Radiographic film illuminator. 892.1890 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1890 Radiographic film illuminator. (a) Identification. A radiographic film illuminator is a device containing a visible light source covered with a...
21 CFR 892.1890 - Radiographic film illuminator.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic film illuminator. 892.1890 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1890 Radiographic film illuminator. (a) Identification. A radiographic film illuminator is a device containing a visible light source covered with a...
32 CFR 707.10 - Wake illumination light.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 32 National Defense 5 2013-07-01 2013-07-01 false Wake illumination light. 707.10 Section 707.10... RESPECT TO ADDITIONAL STATION AND SIGNAL LIGHTS § 707.10 Wake illumination light. Naval vessels may display a white spot light located near the stern to illuminate the wake. ...
32 CFR 707.10 - Wake illumination light.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 32 National Defense 5 2014-07-01 2014-07-01 false Wake illumination light. 707.10 Section 707.10... RESPECT TO ADDITIONAL STATION AND SIGNAL LIGHTS § 707.10 Wake illumination light. Naval vessels may display a white spot light located near the stern to illuminate the wake. ...
32 CFR 707.10 - Wake illumination light.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 32 National Defense 5 2011-07-01 2011-07-01 false Wake illumination light. 707.10 Section 707.10... RESPECT TO ADDITIONAL STATION AND SIGNAL LIGHTS § 707.10 Wake illumination light. Naval vessels may display a white spot light located near the stern to illuminate the wake. ...
32 CFR 707.10 - Wake illumination light.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 32 National Defense 5 2012-07-01 2012-07-01 false Wake illumination light. 707.10 Section 707.10... RESPECT TO ADDITIONAL STATION AND SIGNAL LIGHTS § 707.10 Wake illumination light. Naval vessels may display a white spot light located near the stern to illuminate the wake. ...
Optical Diagnostics for Classifying Stages of Dental Erythema
NASA Astrophysics Data System (ADS)
Davis, Matthew J.; Splinter, Robert; Lockhart, Peter; Brennan, Michael; Fox, Philip C.
2003-02-01
Periodontal disease is a term used to describe an inflammatory disease affecting the tissues surrounding and supporting the teeth. Periodontal diseases are some of the most common chronic disorders, which affect humans in all parts of the world. Treatment usually involves the removal of plaque and calculus by scaling and polishing the tooth. In some cases a surgical reduction of hyperplastic tissue, may also be required. In addition, periodontitis is a risk factor for systemic disorders such as cardiovascular disease and diabetes. Current detection methods are qualitative, inaccurate, and often do not detect the periodontal disease in its early, reversible stages. Therefore, an early detection method should be implemented identifying the relationship of periodontal disease with erythema. In order to achieve this purpose we are developing an optical erythema meter to diagnose the periodontal disease in its reversible, gingival stage. The discrimination between healthy and diseased gum tissue was made by using the reflection of two illuminating wavelengths provided by light emitting diodes operating at wavelengths that target the absorption and reflection spectra of the highlights of each particular tissue type (healthy or diseased, and what kind of disease). Three different color gels could successfully be distinguished with a statistical significance of P < 0.05.
Wagner, Ines; Steinweg, Christian; Posten, Clemens
2016-08-01
Illumination with red and blue photons is known to be efficient for cultivation of higher plants. For microalgae cultivation, illumination with specific wavelengths rather than full spectrum illumination can be an alternative where there is a lack of knowledge about achievable biomass yields. This study deals with the usage of color LED illumination to cultivate microalgae integrated into closed life support systems for outer space. The goal is to quantify biomass yields using color illumination (red, blue, green and mixtures) compared to white light. Chlamydomonas reinhardtii was cultivated in plate reactors with color compared to white illumination regarding PCE, specific pigment concentration and cell size. Highest PCE values were achieved under low PFDs with a red/blue illumination (680 nm/447 nm) at a 90 to 10% molar ratio. At higher PFDs saturation effects can be observed resulting from light absorption characteristics and the linear part of PI curve. Cell size and aggregation are also influenced by the applied light color. Red/blue color illumination is a promising option applicable for microalgae-based modules of life support systems under low to saturating light intensities and double-sided illumination. Results of higher PCE with addition of blue photons to red light indicate an influence of sensory pigments. Copyright © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Zahiruddin, Kowser; Banu, Shaj; Dharmarajan, Ramya; Kulothungan, Vaitheeswaran; Vijayan, Deepa; Raman, Rajiv; Sharma, Tarun
2010-06-01
To evaluate a customized, portable Farnsworth-Munsell 100 (FM 100) hue viewing booth for compliance with colour vision testing standards and to compare it with room illumination in subjects with normal colour vision (trichromats), subjects with acquired colour vision defects (secondary to diabetes mellitus), and subjects with congenital colour vision defects (dichromats). Discrete wavelengths of the tube in the customized booth were measured using a spectrometer using the normal incident method and were compared with the spectral distribution of sunlight. Forty-eight subjects were recruited for the study and were divided into 3 groups: Group 1, Normal Trichromats (30 eyes); Group 2, Congenital Colour Vision Defects (16 eyes); and Group 3, Diabetes Mellitus (20 eyes). The FM 100 hue test performance was compared using two illumination conditions, booth illumination and room illumination. Total error scores of the classical method in Group 2 as mean+/-SD for room and booth illumination was 243.05+/-85.96 and 149.85+/-54.50 respectively (p=0.0001). Group 2 demonstrated lesser correlation (r=0.50, 0.55), lesser reliability (Cronbach's alpha, 0.625, 0.662) and greater variability (Bland & Altman value, 10.5) in total error scores for the classical method and the moment of inertia method between the two illumination conditions when compared to the other two groups. The customized booth demonstrated illumination meeting CIE standards. The total error scores were overestimated by the classical and moment of inertia methods in all groups for room illumination compared with booth illumination, however overestimation was more significant in the diabetes group.
Liu, Ling; Huang, Jin-Sha; Han, Chao; Zhang, Guo-Xin; Xu, Xiao-Yun; Shen, Yan; Li, Jie; Jiang, Hai-Yang; Lin, Zhi-Cheng; Xiong, Nian; Wang, Tao
2016-12-01
Huntington's disease (HD) is an incurable neurodegenerative disorder that is characterized by motor dysfunction, cognitive impairment, and behavioral abnormalities. It is an autosomal dominant disorder caused by a CAG repeat expansion in the huntingtin gene, resulting in progressive neuronal loss predominately in the striatum and cortex. Despite the discovery of the causative gene in 1993, the exact mechanisms underlying HD pathogenesis have yet to be elucidated. Treatments that slow or halt the disease process are currently unavailable. Recent advances in induced pluripotent stem cell (iPSC) technologies have transformed our ability to study disease in human neural cells. Here, we firstly review the progress made to model HD in vitro using patient-derived iPSCs, which reveal unique insights into illuminating molecular mechanisms and provide a novel human cell-based platform for drug discovery. We then highlight the promises and challenges for pluripotent stem cells that might be used as a therapeutic source for cell replacement therapy of the lost neurons in HD brains.
21 CFR 886.1160 - Color vision plate illuminator.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Color vision plate illuminator. 886.1160 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1160 Color vision plate illuminator. (a) Identification. A color vision plate illuminator is an AC-powered device that is a lamp intended...
21 CFR 886.1160 - Color vision plate illuminator.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Color vision plate illuminator. 886.1160 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1160 Color vision plate illuminator. (a) Identification. A color vision plate illuminator is an AC-powered device that is a lamp intended...
21 CFR 886.1160 - Color vision plate illuminator.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Color vision plate illuminator. 886.1160 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1160 Color vision plate illuminator. (a) Identification. A color vision plate illuminator is an AC-powered device that is a lamp intended...
Manufacturing Methods and Technology Program Automatic In-Process Microcircuit Evaluation.
1978-09-01
illumination system consists of an illuminati on controlle r , three illumination power- supplies , and three illuminator housings . The illumination... illuminati on level. - - The main power (115 V , 60 Hz) for the power-supplies is derived from the power distribu- tion panel. There are two switches In the
21 CFR 886.1160 - Color vision plate illuminator.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Color vision plate illuminator. 886.1160 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1160 Color vision plate illuminator. (a) Identification. A color vision plate illuminator is an AC-powered device that is a lamp intended...
21 CFR 886.1160 - Color vision plate illuminator.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Color vision plate illuminator. 886.1160 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1160 Color vision plate illuminator. (a) Identification. A color vision plate illuminator is an AC-powered device that is a lamp intended...
Holographic high-resolution endoscopic image recording
NASA Astrophysics Data System (ADS)
Bjelkhagen, Hans I.
1991-03-01
Endoscopic holography or endoholography combines the features of endoscopy and holography. The purpose of endoholographic imaging is to provide the physician with a unique means of extending diagnosis by providing a life-like record of tissue. Endoholographic recording will provide means for microscopic examination of tissue and in some cases may obviate the need to excise specimens for biopsy. In this method holograms which have the unique properties of three-dimensionality large focal depth and high resolution are made with a newly designed endoscope. The endoscope uses a single-mode optical fiber for illumination and single-beam reflection holograms are recorded in close contact with the tissue at the distal end of the endoscope. The holograms are viewed under a microscope. By using the proper combinations of dyes for staining specific tissue types with various wavelengths of laser illumination increased contrast on the cellular level can be obtained. Using dyes such as rose bengal in combination with the 514. 5 nm line of an argon ion laser and trypan blue or methylene blue with the 647. 1 nm line of a krypton ion laser holograms of the stained colon of a dog showed the architecture of the colon''s columnar epithelial cells. It is hoped through chronological study using this method in-vivo an increased understanding of the etiology and pathology of diseases such as Crohn''s diseases colitis proctitis and several different forms of cancer will help
Human Mendelian pain disorders: a key to discovery and validation of novel analgesics.
Goldberg, Y P; Pimstone, S N; Namdari, R; Price, N; Cohen, C; Sherrington, R P; Hayden, M R
2012-10-01
We have utilized a novel application of human genetics, illuminating the important role that rare genetic disorders can play in the development of novel drugs that may be of relevance for the treatment of both rare and common diseases. By studying a very rare Mendelian disorder of absent pain perception, congenital indifference to pain, we have defined Nav1.7 (endocded by SCN9A) as a critical and novel target for analgesic development. Strong human validation has emerged with SCN9A gain-of-function mutations causing inherited erythromelalgia (IEM) and paroxysmal extreme pain disorder, both Mendelian disorder of spontaneous or easily evoked pain. Furthermore, variations in the Nav1.7 channel also modulate pain perception in healthy subjects as well as in painful conditions such as osteoarthritis and Parkinson disease. On the basis of this, we have developed a novel compound (XEN402) that exhibits potent, voltage-dependent block of Nav1.7. In a small pilot study, we showed that XEN402 blocks Nav1.7 mediated pain associated with IEM thereby demonstrating the use of rare genetic disorders with mutant target channels as a novel approach to rapid proof-of-concept. Our approach underscores the critical role that human genetics can play by illuminating novel and critical pathways pertinent for drug discovery. © 2012 John Wiley & Sons A/S.
Display conditions and lesion detectability: effect of background light
NASA Astrophysics Data System (ADS)
Razavi, Mahmood; Hall, Theodore R.; Aberle, Denise R.; Hayrapetian, Alek S.; Loloyan, Mansur; Eldredge, Sandra L.
1990-08-01
We assessed the effect of high background light on observer performance for the detection of a variety of chest radiographic abnormalities. Five observers reviewed 66 digital hard copy chest images formatted to 1 1 x 14 inch size under two display conditions: 1) on a specially prepared 1 1 x 14 inch illuminated panel with no peripheral light and 2) on a standard viewing panel designed for 14 x 17 inch radiographs. The images contained one - or more of the following conditions: pneumothorax, interstitial disease, nodules, alveolar process, or no abnormality. The results of receiver operator characteristic analysis show that extraneous light does reduce observer performance and the detectability of nodules, interstitial disease.
Hyperspectral microscope for in vivo imaging of microstructures and cells in tissues
Demos,; Stavros, G [Livermore, CA
2011-05-17
An optical hyperspectral/multimodal imaging method and apparatus is utilized to provide high signal sensitivity for implementation of various optical imaging approaches. Such a system utilizes long working distance microscope objectives so as to enable off-axis illumination of predetermined tissue thereby allowing for excitation at any optical wavelength, simplifies design, reduces required optical elements, significantly reduces spectral noise from the optical elements and allows for fast image acquisition enabling high quality imaging in-vivo. Such a technology provides a means of detecting disease at the single cell level such as cancer, precancer, ischemic, traumatic or other type of injury, infection, or other diseases or conditions causing alterations in cells and tissue micro structures.
Flinkman, Mika; Nakauchi, Shigeki
2017-10-01
In this research, three illuminants that improve color discrimination ability of people with red-green color vision deficiency were developed. The illuminants are close to daylight-colored and were produced by using spectral optimization. Deutans were the focus of this research, but a few protans were also tested for reference. The illuminants were produced by combining different types of LEDs, and their effects were tested with several test subjects with and without color vision deficiency using the Ishihara color vision test and the Farnsworth Panel D-15 test. The illuminant with the most powerful effect provided near perfect results with the Ishihara test for deutans, while the other two illuminants produced smaller improvements. The Farnsworth Panel D-15 test produced results that were similar to the Ishihara test though generally the color discrimination of blue hues was weaker under the most powerful illuminant.
Reduction of background clutter in structured lighting systems
Carlson, Jeffrey J.; Giles, Michael K.; Padilla, Denise D.; Davidson, Jr., Patrick A.; Novick, David K.; Wilson, Christopher W.
2010-06-22
Methods for segmenting the reflected light of an illumination source having a characteristic wavelength from background illumination (i.e. clutter) in structured lighting systems can comprise pulsing the light source used to illuminate a scene, pulsing the light source synchronously with the opening of a shutter in an imaging device, estimating the contribution of background clutter by interpolation of images of the scene collected at multiple spectral bands not including the characteristic wavelength and subtracting the estimated background contribution from an image of the scene comprising the wavelength of the light source and, placing a polarizing filter between the imaging device and the scene, where the illumination source can be polarized in the same orientation as the polarizing filter. Apparatus for segmenting the light of an illumination source from background illumination can comprise an illuminator, an image receiver for receiving images of multiple spectral bands, a processor for calculations and interpolations, and a polarizing filter.
Sohn, Martin Y; Barnes, Bryan M; Silver, Richard M
2018-03-01
Accurate optics-based dimensional measurements of features sized well-below the diffraction limit require a thorough understanding of the illumination within the optical column and of the three-dimensional scattered fields that contain the information required for quantitative metrology. Scatterfield microscopy can pair simulations with angle-resolved tool characterization to improve agreement between the experiment and calculated libraries, yielding sub-nanometer parametric uncertainties. Optimized angle-resolved illumination requires bi-telecentric optics in which a telecentric sample plane defined by a Köhler illumination configuration and a telecentric conjugate back focal plane (CBFP) of the objective lens; scanning an aperture or an aperture source at the CBFP allows control of the illumination beam angle at the sample plane with minimal distortion. A bi-telecentric illumination optics have been designed enabling angle-resolved illumination for both aperture and source scanning modes while yielding low distortion and chief ray parallelism. The optimized design features a maximum chief ray angle at the CBFP of 0.002° and maximum wavefront deviations of less than 0.06 λ for angle-resolved illumination beams at the sample plane, holding promise for high quality angle-resolved illumination for improved measurements of deep-subwavelength structures using deep-ultraviolet light.
NASA Astrophysics Data System (ADS)
Yu, You; Han, Yanchao; Xu, Miao; Zhang, Lingling; Dong, Shaojun
2016-04-01
Inverted illumination compensation is important in energy-saving projects, artificial photosynthesis and some forms of agriculture, such as hydroponics. However, only a few illumination adjustments based on self-powered biodetectors that quantitatively detect the intensity of visible light have been reported. We constructed an automatic illumination compensation device based on a photoelectrochemical biofuel cell (PBFC) driven by visible light. The PBFC consisted of a glucose dehydrogenase modified bioanode and a p-type semiconductor cuprous oxide photocathode. The PBFC had a high power output of 161.4 μW cm-2 and an open circuit potential that responded rapidly to visible light. It adjusted the amount of illumination inversely irrespective of how the external illumination was changed. This rational design of utilizing PBFCs provides new insights into automatic light adjustable devices and may be of benefit to intelligent applications.Inverted illumination compensation is important in energy-saving projects, artificial photosynthesis and some forms of agriculture, such as hydroponics. However, only a few illumination adjustments based on self-powered biodetectors that quantitatively detect the intensity of visible light have been reported. We constructed an automatic illumination compensation device based on a photoelectrochemical biofuel cell (PBFC) driven by visible light. The PBFC consisted of a glucose dehydrogenase modified bioanode and a p-type semiconductor cuprous oxide photocathode. The PBFC had a high power output of 161.4 μW cm-2 and an open circuit potential that responded rapidly to visible light. It adjusted the amount of illumination inversely irrespective of how the external illumination was changed. This rational design of utilizing PBFCs provides new insights into automatic light adjustable devices and may be of benefit to intelligent applications. Electronic supplementary information (ESI) available. See DOI: 10.1039/c6nr00759g
Unravelling biology and shifting paradigms in cancer with single-cell sequencing.
Baslan, Timour; Hicks, James
2017-08-24
The fundamental operative unit of a cancer is the genetically and epigenetically innovative single cell. Whether proliferating or quiescent, in the primary tumour mass or disseminated elsewhere, single cells govern the parameters that dictate all facets of the biology of cancer. Thus, single-cell analyses provide the ultimate level of resolution in our quest for a fundamental understanding of this disease. Historically, this quest has been hampered by technological shortcomings. In this Opinion article, we argue that the rapidly evolving field of single-cell sequencing has unshackled the cancer research community of these shortcomings. From furthering an elemental understanding of intra-tumoural genetic heterogeneity and cancer genome evolution to illuminating the governing principles of disease relapse and metastasis, we posit that single-cell sequencing promises to unravel the biology of all facets of this disease.
Energy efficient LED layout optimization for near-uniform illumination
NASA Astrophysics Data System (ADS)
Ali, Ramy E.; Elgala, Hany
2016-09-01
In this paper, we consider the problem of designing energy efficient light emitting diodes (LEDs) layout while satisfying the illumination constraints. Towards this objective, we present a simple approach to the illumination design problem based on the concept of the virtual LED. We formulate a constrained optimization problem for minimizing the power consumption while maintaining a near-uniform illumination throughout the room. By solving the resulting constrained linear program, we obtain the number of required LEDs and the optimal output luminous intensities that achieve the desired illumination constraints.
Enhanced facial texture illumination normalization for face recognition.
Luo, Yong; Guan, Ye-Peng
2015-08-01
An uncontrolled lighting condition is one of the most critical challenges for practical face recognition applications. An enhanced facial texture illumination normalization method is put forward to resolve this challenge. An adaptive relighting algorithm is developed to improve the brightness uniformity of face images. Facial texture is extracted by using an illumination estimation difference algorithm. An anisotropic histogram-stretching algorithm is proposed to minimize the intraclass distance of facial skin and maximize the dynamic range of facial texture distribution. Compared with the existing methods, the proposed method can more effectively eliminate the redundant information of facial skin and illumination. Extensive experiments show that the proposed method has superior performance in normalizing illumination variation and enhancing facial texture features for illumination-insensitive face recognition.
Pulmonary decontamination for photodynamic inactivation with extracorporeal illumination
NASA Astrophysics Data System (ADS)
Geralde, Mariana C.; Leite, Ilaiáli S.; Inada, Natalia M.; Grecco, Clóvis; Medeiros, Alexandra I.; Kurachi, Cristina; Bagnato, Vanderlei S.
2014-03-01
Infectious pneumonia is a major cause of morbidity and mortality, despite advances in diagnostics and therapeutics in pulmonary infections. One of the major difficulties associated with the infection comes from the high rate of antibiotic resistant microorganisms, claiming for the use of alternative techniques with high efficiency and low cost. The photodynamic inactivation (PDI) is emerging as one of the great possibilities in this area, once its action is oxidative, not allowing microorganism develops resistance against the treatment. PDI for decontamination pulmonary has potential for treatment or creating better conditions for the action of antibiotics. In this study, we are developing a device to implement PDI for the treatment of lung diseases with extracorporeal illumination. To validate our theory, we performed measurements in liquid phantom to simulate light penetration in biological tissues at various fluency rates, the temperature was monitored in a body of hairless mice and the measurements of light transmittance in this same animal model. A diode laser emitting at 810 nm in continuous mode was used. Our results show 70% of leakage at 0.5 mm of thickness in phantom model. The mouse body temperature variation was 5.4 °C and was observed light transmittance through its chest. These results are suggesting the possible application of the extracorporeal illumination using infrared light source. Based on these findings, further studies about photodynamic inactivation will be performed in animal model using indocyanine green and bacteriochlorin as photosensitizers. The pulmonary infection will be induced with Streptococcus pneumoniae and Klebsiella pneumoniae.
Rahimy, Ehsan; Reddy, Sahitya; DeCroos, Francis Char; Khan, M Ali; Boyer, David S; Gupta, Omesh P; Regillo, Carl D; Haller, Julia A
2015-08-01
To evaluate the visual acuity agreement between a standard back-illuminated Early Treatment Diabetic Retinopathy Study (ETDRS) chart and a handheld internally illuminated ETDRS chart. Two-center prospective study. Seventy patients (134 eyes) with retinal pathology were enrolled between October 2012 and August 2013. Visual acuity was measured using both the ETDRS chart and the handheld device by masked independent examiners after best protocol refraction. Examination was performed in the same room under identical illumination and testing conditions. The mean number of letters seen was 63.0 (standard deviation: 19.8 letters) and 61.2 letters (standard deviation: 19.1 letters) for the ETDRS chart and handheld device, respectively. Mean difference per eye between the ETDRS and handheld device was 1.8 letters. A correlation coefficient (r) of 0.95 demonstrated a positive linear correlation between ETDRS chart and handheld device measured acuities. Intraclass correlation coefficient was performed to assess the reproducibility of the measurements made by different observers measuring the same quantity and was calculated to be 0.95 (95% confidence interval: 0.93-0.96). Agreement was independent of retinal disease. The strong correlation between measured visual acuity using the ETDRS and handheld equivalent suggests that they may be used interchangeably, with accurate measurements. Potential benefits of this device include convenience and portability, as well as the ability to assess ETDRS visual acuity without a dedicated testing lane.
On-chip ultraviolet holography for high-throughput nanoparticle and biomolecule detection
NASA Astrophysics Data System (ADS)
Daloglu, Mustafa Ugur; Ray, Aniruddha; Gorocs, Zoltán.; Xiong, Matthew; Malik, Ravinder; Bitan, Gal; McLeod, Euan; Ozcan, Aydogan
2018-02-01
Nanoparticle and biomolecule imaging has become an important need for various applications. In an effort to find a higher throughput alternative to existing devices, we have designed a lensfree on-chip holographic imaging platform operating at an ultraviolet (UV) wavelength of 266 nm. With a custom-designed free-space light delivery system to illuminate the sample that is placed very close (<0.5 mm) to an opto-electronic image sensor chip, without any imaging lenses in between, the full active area of the imager chip (>16 mm2 ) was utilized as the imaging field-of-view (FOV) capturing holographic signatures of target objects on a chip. These holograms were then digitally back propagated to extract both the amplitude and phase information of the sample. The increased forward scattering from nanoparticles due to this shorter illumination wavelength has enabled us to image individual particles that are smaller than 30 nm over an FOV of >16 mm2 . Our platform was further utilized in high-contrast imaging of nanoscopic biomolecule aggregates since 266 nm illumination light is strongly absorbed by biomolecules including proteins and nucleic acids. Aggregates of Cu/Zn-superoxide dismutase (SOD1), which has been linked to a fatal neurodegenerative disease, ALS (amyotrophic lateral sclerosis), have been imaged with significantly improved contrast compared to imaging at visible wavelengths. This unique UV imaging modality could be valuable for biomedical applications (e.g., viral load measurements) and environmental monitoring including air and water quality monitoring.
Endoscopic digital holography for measuring flows in opaque vessels
NASA Astrophysics Data System (ADS)
Arévalo, Laura; Palero, Virginia; Lobera, Julia; Arroyo, M. Pilar
2012-10-01
In this work a new application of digital holography for the study of cardio vascular diseases is proposed. The simultaneous measurement of the blood flow velocity and the vein wall deformation can be obtained by combining digital holography and endoscopy. Endoscopes are used for the illumination and recording of digital holograms inside a vein model. Two different endoscopes have been used in different vein models in order to test the technique performance. Preliminary results of flow velocity and wall deformation are presented.
Comparison of two structured illumination techniques based on different 3D illumination patterns
NASA Astrophysics Data System (ADS)
Shabani, H.; Patwary, N.; Doblas, A.; Saavedra, G.; Preza, C.
2017-02-01
Manipulating the excitation pattern in optical microscopy has led to several super-resolution techniques. Among different patterns, the lateral sinusoidal excitation was used for the first demonstration of structured illumination microscopy (SIM), which provides the fastest SIM acquisition system (based on the number of raw images required) compared to the multi-spot illumination approach. Moreover, 3D patterns that include lateral and axial variations in the illumination have attracted more attention recently as they address resolution enhancement in three dimensions. A threewave (3W) interference technique based on coherent illumination has already been shown to provide super-resolution and optical sectioning in 3D-SIM. In this paper, we investigate a novel tunable technique that creates a 3D pattern from a set of multiple incoherently illuminated parallel slits that act as light sources for a Fresnel biprism. This setup is able to modulate the illumination pattern in the object space both axially and laterally with adjustable modulation frequencies. The 3D forward model for the new system is developed here to consider the effect of the axial modulation due to the 3D patterned illumination. The performance of 3D-SIM based on 3W interference and the tunable system are investigated in simulation and compared based on two different criteria. First, restored images obtained for both 3D-SIM systems using a generalized Wiener filter are compared to determine the effect of the illumination pattern on the reconstruction. Second, the effective frequency response of both systems is studied to determine the axial and lateral resolution enhancement that is obtained in each case.
What #theDress reveals about the role of illumination priors in color perception and color constancy
Aston, Stacey; Hurlbert, Anya
2018-01-01
The disagreement between people who named #theDress (the Internet phenomenon of 2015) “blue and black” versus “white and gold” is thought to be caused by individual differences in color constancy. It is hypothesized that observers infer different incident illuminations, relying on illumination “priors” to overcome the ambiguity of the image. Different experiences may drive the formation of different illumination priors, and these may be indicated by differences in chronotype. We assess this hypothesis, asking whether matches to perceived illumination in the image and/or perceived dress colors relate to scores on the morningness-eveningness questionnaire (a measure of chronotype). We find moderate correlations between chronotype and illumination matches (morning types giving bluer illumination matches than evening types) and chronotype and dress body matches, but these are significant only at the 10% level. Further, although inferred illumination chromaticity in the image explains variation in the color matches to the dress (confirming the color constancy hypothesis), color constancy thresholds obtained using an established illumination discrimination task are not related to dress color perception. We also find achromatic settings depend on luminance, suggesting that subjective white point differences may explain the variation in dress color perception only if settings are made at individually tailored luminance levels. The results of such achromatic settings are inconsistent with their assumed correspondence to perceived illumination. Finally, our results suggest that perception and naming are disconnected, with observers reporting different color names for the dress photograph and their isolated color matches, the latter best capturing the variation in the matches. PMID:28793353
Yazar, Tamer; Yazar, Hülya Olgun; Zayimoğlu, Emel; Çankaya, Soner
2018-05-12
In this study, the aim was to identify the incidence of sarcopenia and dynapenia according to disease stage among idiopathic Parkinson's disease (IPD) patients and collect data to illuminate precautions related to reducing the disease load. The study was completed with 166 patients divided by stage according to modified Hoehn and Yahr (HYR) criteria and 249 healthy volunteers aged from 18 to 39 and 68 to 75 years met the inclusion criteria. In our prospective and cross-sectional study, patients with IPD according to "UK Brain Bank" diagnostic criteria had the Unified Parkinson's Disease Rating Scale (UPDRS) and HYR scales applied. The patient and control groups had skeletal muscle mass index (SMMI), muscle power, and physical performance assessed. Diagnosis of sarcopenia used the European Working Group on Sarcopenia in Older People (EWGSOP) diagnostic criteria. In our study, in parallel with the increase in disease stage among IPD patients, the incidence of sarcopenia (led by severe sarcopenia) and dynapenia was high compared to that among the control group of the same age. In the early stages of chronic progressive diseases like IPD, identification of sarcopenia and dynapenia is important considering the limitations of disease-preventive effects in treatments applied after diagnosis.
Miniature self-contained vacuum compatible electronic imaging microscope
Naulleau, Patrick P.; Batson, Phillip J.; Denham, Paul E.; Jones, Michael S.
2001-01-01
A vacuum compatible CCD-based microscopic camera with an integrated illuminator. The camera can provide video or still feed from the microscope contained within a vacuum chamber. Activation of an optional integral illuminator can provide light to illuminate the microscope subject. The microscope camera comprises a housing with a objective port, modified objective, beam-splitter, CCD camera, and LED illuminator.
Xu, Yilei; Roy-Chowdhury, Amit K
2007-05-01
In this paper, we present a theory for combining the effects of motion, illumination, 3D structure, albedo, and camera parameters in a sequence of images obtained by a perspective camera. We show that the set of all Lambertian reflectance functions of a moving object, at any position, illuminated by arbitrarily distant light sources, lies "close" to a bilinear subspace consisting of nine illumination variables and six motion variables. This result implies that, given an arbitrary video sequence, it is possible to recover the 3D structure, motion, and illumination conditions simultaneously using the bilinear subspace formulation. The derivation builds upon existing work on linear subspace representations of reflectance by generalizing it to moving objects. Lighting can change slowly or suddenly, locally or globally, and can originate from a combination of point and extended sources. We experimentally compare the results of our theory with ground truth data and also provide results on real data by using video sequences of a 3D face and the entire human body with various combinations of motion and illumination directions. We also show results of our theory in estimating 3D motion and illumination model parameters from a video sequence.
Real-time global illumination on mobile device
NASA Astrophysics Data System (ADS)
Ahn, Minsu; Ha, Inwoo; Lee, Hyong-Euk; Kim, James D. K.
2014-02-01
We propose a novel method for real-time global illumination on mobile devices. Our approach is based on instant radiosity, which uses a sequence of virtual point lights in order to represent the e ect of indirect illumination. Our rendering process consists of three stages. With the primary light, the rst stage generates a local illumination with the shadow map on GPU The second stage of the global illumination uses the re ective shadow map on GPU and generates the sequence of virtual point lights on CPU. Finally, we use the splatting method of Dachsbacher et al 1 and add the indirect illumination to the local illumination on GPU. With the limited computing resources in mobile devices, a small number of virtual point lights are allowed for real-time rendering. Our approach uses the multi-resolution sampling method with 3D geometry and attributes simultaneously and reduce the total number of virtual point lights. We also use the hybrid strategy, which collaboratively combines the CPUs and GPUs available in a mobile SoC due to the limited computing resources in mobile devices. Experimental results demonstrate the global illumination performance of the proposed method.
Side-emitting illuminators using LED sources
NASA Astrophysics Data System (ADS)
Zhao, Feng; Van Derlofske, John F.
2003-11-01
This study investigates illuminators composed of light emitting diode (LED) array sources and side-emitting light guides to provide efficient general illumination. Specifically, new geometries are explored to increase the efficiency of current systems while maintaining desired light distribution. LED technology is already successfully applied in many illumination applications, such as traffic signals and liquid crystal display (LCD) backlighting. It provides energy-efficient, small-package, long-life, and color-adjustable illumination. However, the use of LEDs in general illumination is still in its early stages. Current side-emitting systems typically use a light guide with light sources at one end, an end-cap surface at the other end, and light releasing sidewalls. This geometry introduces efficiency loss that can be as high as 40%. The illuminators analyzed in this study use LED array sources along the longitude of a light guide to increase the system efficiency. These new geometries also provide the freedom of elongating the system without sacrificing system efficiency. In addition, alternative geometries can be used to create white light with monochromatic LED sources. As concluded by this study, the side-emitting illuminators using LED sources gives the possibility of an efficient, distribution-controllable linear lighting system.
Microscopy illumination engineering using a low-cost liquid crystal display.
Guo, Kaikai; Bian, Zichao; Dong, Siyuan; Nanda, Pariksheet; Wang, Ying Min; Zheng, Guoan
2015-02-01
Illumination engineering is critical for obtaining high-resolution, high-quality images in microscope settings. In a typical microscope, the condenser lens provides sample illumination that is uniform and free from glare. The associated condenser diaphragm can be manually adjusted to obtain the optimal illumination numerical aperture. In this paper, we report a programmable condenser lens for active illumination control. In our prototype setup, we used a $15 liquid crystal display as a transparent spatial light modulator and placed it at the back focal plane of the condenser lens. By setting different binary patterns on the display, we can actively control the illumination and the spatial coherence of the microscope platform. We demonstrated the use of such a simple scheme for multimodal imaging, including bright-field microscopy, darkfield microscopy, phase-contrast microscopy, polarization microscopy, 3D tomographic imaging, and super-resolution Fourier ptychographic imaging. The reported illumination engineering scheme is cost-effective and compatible with most existing platforms. It enables a turnkey solution with high flexibility for researchers in various communities. From the engineering point-of-view, the reported illumination scheme may also provide new insights for the development of multimodal microscopy and Fourier ptychographic imaging.
The importance of illumination in nest site choice and nest characteristics of cavity nesting birds.
Podkowa, Paweł; Surmacki, Adrian
2017-05-02
Light has a significant impact on many aspects of avian biology, physiology and behaviour. An increasing number of studies show that illumination may positively influences birds' offspring fitness by e.g. acceleration of embryo development, stimulation of skeleton growth or regulation of circadian rhythm. Because nest cavities have especially low illumination, suitable light levels may be especially important for species which nest there. We may therefore expect that birds breeding in relatively dim conditions should prefer brighter nest sites and/or evolve behavioral mechanisms to secure sufficient light levels in the nest. Using nest boxes with modified internal illumination, we experimentally tested whether light regime is a cue for nest site selection of secondary cavity-nesting species. Additionally, we investigated whether nest building strategies are tuned to internal illumination. Our results demonstrate that, nest boxes with elevated illumination were chosen twice as often as dark nest boxes. Moreover, birds built higher nests in dark nest boxes than birds in boxes with elevated illumination, which suggests a mechanism of compensating for low light conditions. Our results provide the first experimental support for the idea that nest site choice and nest building behaviour in cavity-nesting birds are influenced by ambient illumination.
Multiple Illuminant Colour Estimation via Statistical Inference on Factor Graphs.
Mutimbu, Lawrence; Robles-Kelly, Antonio
2016-08-31
This paper presents a method to recover a spatially varying illuminant colour estimate from scenes lit by multiple light sources. Starting with the image formation process, we formulate the illuminant recovery problem in a statistically datadriven setting. To do this, we use a factor graph defined across the scale space of the input image. In the graph, we utilise a set of illuminant prototypes computed using a data driven approach. As a result, our method delivers a pixelwise illuminant colour estimate being devoid of libraries or user input. The use of a factor graph also allows for the illuminant estimates to be recovered making use of a maximum a posteriori (MAP) inference process. Moreover, we compute the probability marginals by performing a Delaunay triangulation on our factor graph. We illustrate the utility of our method for pixelwise illuminant colour recovery on widely available datasets and compare against a number of alternatives. We also show sample colour correction results on real-world images.
Oonincx, D G A B; Volk, N; Diehl, J J E; van Loon, J J A; Belušič, G
2016-12-01
Mating in the black soldier fly (BSF) is a visually mediated behaviour that under natural conditions occurs in full sunlight. Artificial light conditions promoting mating by BSF were designed based on the spectral characteristics of the compound eye retina. Electrophysiological measurements revealed that BSF ommatidia contained UV-, blue- and green-sensitive photoreceptor cells, allowing trichromatic vision. An illumination system for indoor breeding based on UV, blue and green LEDs was designed and its efficiency was compared with illumination by fluorescent tubes which have been successfully used to sustain a BSF colony for five years. Illumination by LEDs and the fluorescent tubes yielded equal numbers of egg clutches, however, the LED illumination resulted in significantly more larvae. The possibilities to optimize the current LED illumination system to better approximate the skylight illuminant and potentially optimize the larval yield are discussed. Copyright © 2016 Elsevier Ltd. All rights reserved.
Interconnectivity of human cellular metabolism and disease prevalence
NASA Astrophysics Data System (ADS)
Lee, Deok-Sun
2010-12-01
Fluctuations of metabolic reaction fluxes may cause abnormal concentrations of toxic or essential metabolites, possibly leading to metabolic diseases. The mutual binding of enzymatic proteins and ones involving common metabolites enforces distinct coupled reactions, by which local perturbations may spread through the cellular network. Such network effects at the molecular interaction level in human cellular metabolism can reappear in the patterns of disease occurrence. Here we construct the enzyme-reaction network and the metabolite-reaction network, capturing the flux coupling of metabolic reactions caused by the interacting enzymes and the shared metabolites, respectively. Diseases potentially caused by the failure of individual metabolic reactions can be identified by using the known disease-gene association, which allows us to derive the probability of an inactivated reaction causing diseases from the disease records at the population level. We find that the greater the number of proteins that catalyze a reaction, the higher the mean prevalence of its associated diseases. Moreover, the number of connected reactions and the mean size of the avalanches in the networks constructed are also shown to be positively correlated with the disease prevalence. These findings illuminate the impact of the cellular network topology on disease development, suggesting that the global organization of the molecular interaction network should be understood to assist in disease diagnosis, treatment, and drug discovery.
Content-based fused off-axis object illumination direct-to-digital holography
Price, Jeffery R.
2006-05-02
Systems and methods are described for content-based fused off-axis illumination direct-to-digital holography. A method includes calculating an illumination angle with respect to an optical axis defined by a focusing lens as a function of data representing a Fourier analyzed spatially heterodyne hologram; reflecting a reference beam from a reference mirror at a non-normal angle; reflecting an object beam from an object the object beam incident upon the object at the illumination angle; focusing the reference beam and the object beam at a focal plane of a digital recorder to from the content-based off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes for Fourier analysis; and digitally recording the content based off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes for Fourier analysis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mielenz, K.D.; Hsia, J.J.
1990-01-01
The differences between ITS-90 and IPTS-68 (International Practical Temperature Scale of 1968) above 1235 K are described. It is shown that none of the following CIE (Commission Internationale de l'Eclairage or International Commission on Illumination) definitions or recommendations require revision because of the introduction of the ITS-90: International Lighting Vocabulary definitions; CIE Standard Illuminants A, D(65), other illuminants; and sources for realizing CIE Illuminants. The effect of the ITS-90 on previously calibrated sources for realizing CIE illuminants is negligibly small.
Kim, Min-Jeong; Yuk, Hyun-Gyun
2017-03-01
The aim of this study was to elucidate the antibacterial mechanism of 405 ± 5-nm light-emitting diode (LED) illumination against Salmonella at 4°C in phosphate-buffered saline (PBS) by determining endogenous coproporphyrin content, DNA oxidation, damage to membrane function, and morphological change. Gene expression levels, including of oxyR , recA , rpoS , sodA , and soxR , were also examined to understand the response of Salmonella to LED illumination. The results showed that Salmonella strains responded differently to LED illumination, revealing that S. enterica serovar Enteritidis (ATCC 13076) and S. enterica subsp. enterica serovar Saintpaul (ATCC 9712) were more susceptible and resistant, respectively, than the 16 other strains tested. There was no difference in the amounts of endogenous coproporphyrin in the two strains. Compared with that in nonilluminated cells, the DNA oxidation levels in illuminated cells increased. In illuminated cells, we observed a loss of efflux pump activity, damage to the glucose uptake system, and changes in membrane potential and integrity. Transmission electron microscopy revealed a disorganization of chromosomes and ribosomes due to LED illumination. The levels of the five genes measured in the nonilluminated and illuminated S Saintpaul cells were upregulated in PBS at a set temperature of 4°C, indicating that increased gene expression levels might be due to a temperature shift and nutrient deficiency rather than to LED illumination. In contrast, only oxyR in S Enteritidis cells was upregulated. Thus, different sensitivities of the two strains to LED illumination were attributed to differences in gene regulation. IMPORTANCE Bacterial inactivation using visible light has recently received attention as a safe and environmentally friendly technology, in contrast with UV light, which has detrimental effects on human health and the environment. This study was designed to understand how 405 ± 5-nm light-emitting diode (LED) illumination kills Salmonella strains at refrigeration temperature. The data clearly demonstrated that the effectiveness of LED illumination on Salmonella strains depended highly on the serotype and strain. Our findings also revealed that its antibacterial mechanism was mainly attributed to DNA oxidation and a loss of membrane functions rather than membrane lipid peroxidation, which has been proposed by other researchers who studied the antibacterial effect of LED illumination by adding exogenous photosensitizers, such as chlorophyllin and hypericin. Therefore, this study suggests that the detailed antibacterial mechanisms of 405-nm LED illumination without additional photosensitizers may differ from that by exogenous photosensitizers. Furthermore, a change in stress-related gene regulation may alter the susceptibility of Salmonella cells to LED illumination at refrigeration temperature. Thus, our study provides new insights into the antibacterial mechanism of 405 ± 5-nm LED illumination on Salmonella cells. Copyright © 2017 American Society for Microbiology.
Kim, Min-Jeong
2016-01-01
ABSTRACT The aim of this study was to elucidate the antibacterial mechanism of 405 ± 5-nm light-emitting diode (LED) illumination against Salmonella at 4°C in phosphate-buffered saline (PBS) by determining endogenous coproporphyrin content, DNA oxidation, damage to membrane function, and morphological change. Gene expression levels, including of oxyR, recA, rpoS, sodA, and soxR, were also examined to understand the response of Salmonella to LED illumination. The results showed that Salmonella strains responded differently to LED illumination, revealing that S. enterica serovar Enteritidis (ATCC 13076) and S. enterica subsp. enterica serovar Saintpaul (ATCC 9712) were more susceptible and resistant, respectively, than the 16 other strains tested. There was no difference in the amounts of endogenous coproporphyrin in the two strains. Compared with that in nonilluminated cells, the DNA oxidation levels in illuminated cells increased. In illuminated cells, we observed a loss of efflux pump activity, damage to the glucose uptake system, and changes in membrane potential and integrity. Transmission electron microscopy revealed a disorganization of chromosomes and ribosomes due to LED illumination. The levels of the five genes measured in the nonilluminated and illuminated S. Saintpaul cells were upregulated in PBS at a set temperature of 4°C, indicating that increased gene expression levels might be due to a temperature shift and nutrient deficiency rather than to LED illumination. In contrast, only oxyR in S. Enteritidis cells was upregulated. Thus, different sensitivities of the two strains to LED illumination were attributed to differences in gene regulation. IMPORTANCE Bacterial inactivation using visible light has recently received attention as a safe and environmentally friendly technology, in contrast with UV light, which has detrimental effects on human health and the environment. This study was designed to understand how 405 ± 5-nm light-emitting diode (LED) illumination kills Salmonella strains at refrigeration temperature. The data clearly demonstrated that the effectiveness of LED illumination on Salmonella strains depended highly on the serotype and strain. Our findings also revealed that its antibacterial mechanism was mainly attributed to DNA oxidation and a loss of membrane functions rather than membrane lipid peroxidation, which has been proposed by other researchers who studied the antibacterial effect of LED illumination by adding exogenous photosensitizers, such as chlorophyllin and hypericin. Therefore, this study suggests that the detailed antibacterial mechanisms of 405-nm LED illumination without additional photosensitizers may differ from that by exogenous photosensitizers. Furthermore, a change in stress-related gene regulation may alter the susceptibility of Salmonella cells to LED illumination at refrigeration temperature. Thus, our study provides new insights into the antibacterial mechanism of 405 ± 5-nm LED illumination on Salmonella cells. PMID:28003197
NASA Astrophysics Data System (ADS)
van den Boogert, Jolanda; de Bruin, Ron W. F.; van Staveren, Hugo J.; Siersema, Peter D.; van Hillegersberg, Richard
1999-02-01
Photodynamic therapy (PDT) is an experimental treatment modality for (pre)malignant oesophageal lesions. 5- Aminolevulinic acid (ALA)-induced, protoporphyrin IX (PpIX)- mediated photo-sensitization could be very useful as ALA- induced porphrin accumulation selectively occurs in the oesophageal epithelium. The present study aimed to optimize the time between illumination and the administration of ALA. 200 mg/kg ALA was given orally to 24 rats (allocated to 6 groups of 4 animals each). Four animals served as controls and received phosphate buffered saline orally. The animals were illuminated at various time-points (either 1, 2, 3, 4, 6, or 12 hours) after ALA administration. Illumination was performed with a cylindrical diffuser placed in a balloon catheter. The device was originally made for percutaneous transluminal coronary angioplasty and consisted of a semi-flexible catheter and an inflatable cylindric optically clear balloon. The diffuser was placed centrally in the catheter. The same illumination parameters (633 nm, 25 J radiant energy/cm diffuser, power output 100 mW/cm diffuser) were used for each animal. During illumination, fluorescence measurements and light dosimetry were performed. The animals were sacrificed at 48 hours after PDT for histological assessment. Highest PpIX fluorescence was found at 2, 3, and 4 hours after ALA administration. Dosimetric measurements showed a 2 - 3 times higher in vivo fluence rate compared to the estimated fluence rate. Histology at 48 hours after PDT showed diffuse epithelial damage at the laser site only in rats illuminated at 2 hours after ALA administration. Illumination at 3, 4, and 6 hours after ALA administration resulted in diffuse epithelial damage in only one of four rats. In none of the rats illuminated at 1 and 12 hours after administration of ALA epithelial damage was found. These results show that illumination at 2 hours after oral ALA administration provides an efficient and safe scheme for ALA-PDT in the normal rat oesophagus. Illumination at other time points results in incomplete epithelial damage.
NASA Astrophysics Data System (ADS)
Lizotte, Todd E.; Ohar, Orest
2004-02-01
Illuminators used in machine vision applications typically produce non-uniform illumination onto the targeted surface being observed, causing a variety of problems with machine vision alignment or measurement. In most circumstances the light source is broad spectrum, leading to further problems with image quality when viewed through a CCD camera. Configured with a simple light bulb and a mirrored reflector and/or frosted glass plates, these general illuminators are appropriate for only macro applications. Over the last 5 years newer illuminators have hit the market including circular or rectangular arrays of high intensity light emitting diodes. These diode arrays are used to create monochromatic flood illumination of a surface that is to be inspected. The problem with these illumination techniques is that most of the light does not illuminate the desired areas, but broadly spreads across the surface, or when integrated with diffuser elements, tend to create similar shadowing effects to the broad spectrum light sources. In many cases a user will try to increase the performance of these illuminators by adding several of these assemblies together, increasing the intensity or by moving the illumination source closer or farther from the surface being inspected. In this case these non-uniform techniques can lead to machine vision errors, where the computer machine vision may read false information, such as interpreting non-uniform lighting or shadowing effects as defects. This paper will cover a technique involving the use of holographic / diffractive hybrid optical elements that are integrated into standard and customized light sources used in the machine vision industry. The bulk of the paper will describe the function and fabrication of the holographic/diffractive optics and how they can be tailored to improve illuminator design. Further information will be provided a specific design and examples of it in operation will be disclosed.
Effects of chromatic image statistics on illumination induced color differences.
Lucassen, Marcel P; Gevers, Theo; Gijsenij, Arjan; Dekker, Niels
2013-09-01
We measure the color fidelity of visual scenes that are rendered under different (simulated) illuminants and shown on a calibrated LCD display. Observers make triad illuminant comparisons involving the renderings from two chromatic test illuminants and one achromatic reference illuminant shown simultaneously. Four chromatic test illuminants are used: two along the daylight locus (yellow and blue), and two perpendicular to it (red and green). The observers select the rendering having the best color fidelity, thereby indirectly judging which of the two test illuminants induces the smallest color differences compared to the reference. Both multicolor test scenes and natural scenes are studied. The multicolor scenes are synthesized and represent ellipsoidal distributions in CIELAB chromaticity space having the same mean chromaticity but different chromatic orientations. We show that, for those distributions, color fidelity is best when the vector of the illuminant change (pointing from neutral to chromatic) is parallel to the major axis of the scene's chromatic distribution. For our selection of natural scenes, which generally have much broader chromatic distributions, we measure a higher color fidelity for the yellow and blue illuminants than for red and green. Scrambled versions of the natural images are also studied to exclude possible semantic effects. We quantitatively predict the average observer response (i.e., the illuminant probability) with four types of models, differing in the extent to which they incorporate information processing by the visual system. Results show different levels of performance for the models, and different levels for the multicolor scenes and the natural scenes. Overall, models based on the scene averaged color difference have the best performance. We discuss how color constancy algorithms may be improved by exploiting knowledge of the chromatic distribution of the visual scene.
Oleari, Claudio; Melgosa, Manuel; Huertas, Rafael
2011-11-01
The most widely used color-difference formulas are based on color-difference data obtained under D65 illumination or similar and for a 10° visual field; i.e., these formulas hold true for the CIE 1964 observer adapted to D65 illuminant. This work considers the psychometric color-vision model based on the Optical Society of America-Uniform Color Scales (OSA-UCS) system previously published by the first author [J. Opt. Soc. Am. A 21, 677 (2004); Color Res. Appl. 30, 31 (2005)] with the additional hypothesis that complete illuminant adaptation with perfect color constancy exists in the visual evaluation of color differences. In this way a computational procedure is defined for color conversion between different illuminant adaptations, which is an alternative to the current chromatic adaptation transforms. This color conversion allows the passage between different observers, e.g., CIE 1964 and CIE 1931. An application of this color conversion is here made in the color-difference evaluation for any observer and in any illuminant adaptation: these transformations convert tristimulus values related to any observer and illuminant adaptation to those related to the observer and illuminant adaptation of the definition of the color-difference formulas, i.e., to the CIE 1964 observer adapted to the D65 illuminant, and then the known color-difference formulas can be applied. The adaptations to the illuminants A, C, F11, D50, Planckian and daylight at any color temperature and for CIE 1931 and CIE 1964 observers are considered as examples, and all the corresponding transformations are given for practical use.
Motoneuron firing in amyotrophic lateral sclerosis (ALS)
de Carvalho, Mamede; Eisen, Andrew; Krieger, Charles; Swash, Michael
2014-01-01
Amyotrophic lateral sclerosis is an inexorably progressive neurodegenerative disorder involving the classical motor system and the frontal effector brain, causing muscular weakness and atrophy, with variable upper motor neuron signs and often an associated fronto-temporal dementia. The physiological disturbance consequent on the motor system degeneration is beginning to be well understood. In this review we describe aspects of the motor cortical, neuronal, and lower motor neuron dysfunction. We show how studies of the changes in the pattern of motor unit firing help delineate the underlying pathophysiological disturbance as the disease progresses. Such studies are beginning to illuminate the underlying disordered pathophysiological processes in the disease, and are important in designing new approaches to therapy and especially for clinical trials. PMID:25294995
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnston, R.; McIvor, A.
2004-07-01
This essay uses oral histories of dust disease in twentieth-century Scotland to illustrate the ways in which such history can illuminate how the working environment and work cultures affect workers' bodies and how workers come to terms with the ill-health caused by their employment. It emphasizes the agency of the interpreter but argues further that oral histories of dust disease in twentieth-century Scotland are simultaneously influenced by, and evidence for, material conditions. The essay explores the notion that the bodies, not just the voices of interviewees, are material testament to health-corroding work practices, cultures, and habitat. The focus is themore » problems caused by the inhalation of coal and asbestos dust.« less
Tolerancing a lens for LED uniform illumination
NASA Astrophysics Data System (ADS)
Ryu, Jieun; Sasian, Jose
2017-08-01
A method to evaluate tolerance sensitivities for lenses used to produce uniform illumination is presented. Closed form surfaces are used to define optical surfaces and relative illumination is calculated from light etendue considerations.
Dual LED/incandescent security fixture
Gauna, Kevin Wayne
2005-06-21
A dual LED and incandescent security lighting system uses a hybrid approach to LED illumination. It combines an ambient LED illuminator with a standard incandescent lamp on a motion control sensor. The LED illuminator will activate with the onset of darkness (daylight control) and typically remain on during the course of the night ("always on"). The LED illumination, typically amber, is sufficient to provide low to moderate level lighting coverage to the wall and ground area adjacent to and under the fixture. The incandescent lamp is integrated with a motion control circuit and sensor. When movement in the field of view is detected (after darkness), the incandescent lamp is switched on, providing an increased level of illumination to the area. Instead of an "always on" LED illuminator, the LEDs may also be switched off when the incandescent lamp is switched on.
Hennessy, Elizabeth J; Moore, Kathryn J
2013-09-01
It is now appreciated that over 90% of the human genome is comprised of noncoding RNAs that have the ability to affect other components of the genome and regulate gene expression. This has galvanized the development of RNA-based therapeutics for a myriad of diseases, including cancer, inflammatory conditions, and cardiovascular disease. Several classes of RNA therapeutics are currently under clinical development, including antisense oligonucleotides, small interfering RNA, and microRNA mimetics and inhibitors. The field of antisense technology saw a huge leap forward with the recent Food and Drug Administration approval of the first antisense therapy, directed against apolipoprotein B, for the treatment of familial hypercholesterolemia. In addition, recent progress in the development of approaches to inhibit microRNAs has helped to illuminate their roles in repressing gene networks and also revealed their potential as therapeutic targets. In this review, these exciting opportunities in the field of drug discovery, with a focus on emerging therapeutics in the field of cardiovascular disease, are summarized.
Inherited dystonias: clinical features and molecular pathways.
Weisheit, Corinne E; Pappas, Samuel S; Dauer, William T
2018-01-01
Recent decades have witnessed dramatic increases in understanding of the genetics of dystonia - a movement disorder characterized by involuntary twisting and abnormal posture. Hampered by a lack of overt neuropathology, researchers are investigating isolated monogenic causes to pinpoint common molecular mechanisms in this heterogeneous disease. Evidence from imaging, cellular, and murine work implicates deficiencies in dopamine neurotransmission, transcriptional dysregulation, and selective vulnerability of distinct neuronal populations to disease mutations. Studies of genetic forms of dystonia are also illuminating the developmental dependence of disease symptoms that is typical of many forms of the disease. As understanding of monogenic forms of dystonia grows, a clearer picture will develop of the abnormal motor circuitry behind this relatively common phenomenology. This chapter focuses on the current data covering the etiology and epidemiology, clinical presentation, and pathogenesis of four monogenic forms of isolated dystonia: DYT-TOR1A, DYT-THAP1, DYT-GCH1, and DYT-GNAL. Copyright © 2018 Elsevier B.V. All rights reserved.
Cancer genetics meets biomolecular mechanism-bridging an age-old gulf.
González-Sánchez, Juan Carlos; Raimondi, Francesco; Russell, Robert B
2018-02-01
Increasingly available genomic sequencing data are exploited to identify genes and variants contributing to diseases, particularly cancer. Traditionally, methods to find such variants have relied heavily on allele frequency and/or familial history, often neglecting to consider any mechanistic understanding of their functional consequences. Thus, while the set of known cancer-related genes has increased, for many, their mechanistic role in the disease is not completely understood. This issue highlights a wide gap between the disciplines of genetics, which largely aims to correlate genetic events with phenotype, and molecular biology, which ultimately aims at a mechanistic understanding of biological processes. Fortunately, new methods and several systematic studies have proved illuminating for many disease genes and variants by integrating sequencing with mechanistic data, including biomolecular structures and interactions. These have provided new interpretations for known mutations and suggested new disease-relevant variants and genes. Here, we review these approaches and discuss particular examples where these have had a profound impact on the understanding of human cancers. © 2018 Federation of European Biochemical Societies.
Psychodynamic theory and counseling in predictive testing for Huntington's disease.
Tassicker, Roslyn J
2005-04-01
This paper revisits psychodynamic theory, which can be applied in predictive testing counseling for Huntington's Disease (HD). Psychodynamic theory has developed from the work of Freud and places importance on early parent-child experiences. The nature of these relationships, or attachments are reflected in adult expectations and relationships. Two significant concepts, identification and fear of abandonment, have been developed and expounded by the psychodynamic theorist, Melanie Klein. The processes of identification and fear of abandonment can become evident in predictive testing counseling and are colored by the client's experience of growing up with a parent affected by Huntington's Disease. In reflecting on family-of-origin experiences, clients can also express implied expectations of the future, and future relationships. Case examples are given to illustrate the dynamic processes of identification and fear of abandonment which may present in the clinical setting. Counselor recognition of these processes can illuminate and inform counseling practice.
2013-01-01
Advances in stress physiology and molecular dynamics can illuminate population health inequality. The “weathering” hypothesis posits that socially structured, repeated stress process activation can accumulate and increase disease vulnerability across the life course in marginalized groups. The developmental origins of health and disease (DOHaD) hypothesis focuses on youthful programming for later life disease via epigenetic modifications to limiting uterine or early environments. Weathering and DOHaD are overlapping biopsychosocial models; yet, their emphases and implications vary. Evidence for the primacy of early development over experiences in young through middle adulthood for explaining population health inequality is lacking. By considering weathering and DOHaD together, we call for biomedical researchers to be more cautious in their claims about the social world and for a broader range of social researchers—including qualitative ones—to collaborate with them. PMID:23927509
Laser agile illumination for object tracking and classification - Feasibility study
NASA Technical Reports Server (NTRS)
Scholl, Marija S.; Vanzyl, Jakob J.; Meinel, Aden B.; Meinel, Marjorie P.; Scholl, James W.
1988-01-01
The 'agile illumination' concept for discrimination between ICBM warheads and decoys involves a two-aperture illumination with coherent light, diffraction of light by propagation, and a resulting interference pattern on the object surface. A scanning two-beam interference pattern illuminates one object at a time; depending on the shape, momentum, spinning, and tumbling characteristics of the interrogated object, different temporal signals will be obtained for different classes of objects.
Huang, Hsin-Tao; Tsai, Chuang-Chuang; Huang, Yi-Pai
2010-08-01
The UV-excited flat lighting (UFL) technique differs from conventional fluorescent lamp or LED illumination. It involves using a remote phosphor film to convert the wavelength of UV light to visible light, achieving high brightness and planar and uniform illumination. In particular, UFL can accomplish compact size, low power consumption, and symmetrical dual-sided illumination. Additionally, UFL utilizes a thermal radiation mechanism to release the large amount of heat that is generated upon illumination without thermal accumulation. These characteristics of the UFL technique can motivate a wide range of lighting applications in thin-film transistor LCD backlighting or general lighting.
Hertog, W; Llenas, A; Carreras, J
2015-11-30
This article demonstrates the benefits of complementing a daylight-lit environment with a spectrally tunable illumination system. The spectral components of daylight present in the room are measured by a low-cost miniature spectrophotometer and processed through a number of optimization algorithms, carefully trading color fidelity for energy efficiency. Spectrally-tunable luminaires provide only those wavelengths that ensure that either the final illumination spectrum inside the room is kept constant or carefully follows the dynamic spectral pattern of natural daylight. Analyzing the measured data proves that such a hybrid illumination system brings both unprecendented illumination quality and significant energy savings.
Off-axis illumination direct-to-digital holography
Thomas, Clarence E.; Price, Jeffery R.; Voelkl, Edgar; Hanson, Gregory R.
2004-06-08
Systems and methods are described for off-axis illumination direct-to-digital holography. A method of recording an off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes for Fourier analysis, includes: reflecting a reference beam from a reference mirror at a non-normal angle; reflecting an object beam from an object at an angle with respect to an optical axis defined by a focusing lens; focusing the reference beam and the object beam at a focal plane of a digital recorder to form the off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes for Fourier analysis; digitally recording the off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes for Fourier analysis; Fourier analyzing the recorded off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes by transforming axes of the recorded off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes in Fourier space to sit on top of a heterodyne carrier frequency defined as an angle between the reference beam and the object beam; applying a digital filter to cut off signals around an original origin; and then performing an inverse Fourier transform.
Digital micromirror device-based laser-illumination Fourier ptychographic microscopy
Kuang, Cuifang; Ma, Ye; Zhou, Renjie; Lee, Justin; Barbastathis, George; Dasari, Ramachandra R.; Yaqoob, Zahid; So, Peter T. C.
2015-01-01
We report a novel approach to Fourier ptychographic microscopy (FPM) by using a digital micromirror device (DMD) and a coherent laser source (532 nm) for generating spatially modulated sample illumination. Previously demonstrated FPM systems are all based on partially-coherent illumination, which offers limited throughput due to insufficient brightness. Our FPM employs a high power coherent laser source to enable shot-noise limited high-speed imaging. For the first time, a digital micromirror device (DMD), imaged onto the back focal plane of the illumination objective, is used to generate spatially modulated sample illumination field for ptychography. By coding the on/off states of the micromirrors, the illumination plane wave angle can be varied at speeds more than 4 kHz. A set of intensity images, resulting from different oblique illuminations, are used to numerically reconstruct one high-resolution image without obvious laser speckle. Experiments were conducted using a USAF resolution target and a fiber sample, demonstrating high-resolution imaging capability of our system. We envision that our approach, if combined with a coded-aperture compressive-sensing algorithm, will further improve the imaging speed in DMD-based FPM systems. PMID:26480361
Digital micromirror device-based laser-illumination Fourier ptychographic microscopy.
Kuang, Cuifang; Ma, Ye; Zhou, Renjie; Lee, Justin; Barbastathis, George; Dasari, Ramachandra R; Yaqoob, Zahid; So, Peter T C
2015-10-19
We report a novel approach to Fourier ptychographic microscopy (FPM) by using a digital micromirror device (DMD) and a coherent laser source (532 nm) for generating spatially modulated sample illumination. Previously demonstrated FPM systems are all based on partially-coherent illumination, which offers limited throughput due to insufficient brightness. Our FPM employs a high power coherent laser source to enable shot-noise limited high-speed imaging. For the first time, a digital micromirror device (DMD), imaged onto the back focal plane of the illumination objective, is used to generate spatially modulated sample illumination field for ptychography. By coding the on/off states of the micromirrors, the illumination plane wave angle can be varied at speeds more than 4 kHz. A set of intensity images, resulting from different oblique illuminations, are used to numerically reconstruct one high-resolution image without obvious laser speckle. Experiments were conducted using a USAF resolution target and a fiber sample, demonstrating high-resolution imaging capability of our system. We envision that our approach, if combined with a coded-aperture compressive-sensing algorithm, will further improve the imaging speed in DMD-based FPM systems.
Color constancy in 3D-2D face recognition
NASA Astrophysics Data System (ADS)
Meyer, Manuel; Riess, Christian; Angelopoulou, Elli; Evangelopoulos, Georgios; Kakadiaris, Ioannis A.
2013-05-01
Face is one of the most popular biometric modalities. However, up to now, color is rarely actively used in face recognition. Yet, it is well-known that when a person recognizes a face, color cues can become as important as shape, especially when combined with the ability of people to identify the color of objects independent of illuminant color variations. In this paper, we examine the feasibility and effect of explicitly embedding illuminant color information in face recognition systems. We empirically examine the theoretical maximum gain of including known illuminant color to a 3D-2D face recognition system. We also investigate the impact of using computational color constancy methods for estimating the illuminant color, which is then incorporated into the face recognition framework. Our experiments show that under close-to-ideal illumination estimates, one can improve face recognition rates by 16%. When the illuminant color is algorithmically estimated, the improvement is approximately 5%. These results suggest that color constancy has a positive impact on face recognition, but the accuracy of the illuminant color estimate has a considerable effect on its benefits.
High-resolution imaging using endoscopic holography
NASA Astrophysics Data System (ADS)
Bjelkhagen, Hans I.
1990-08-01
Endoscopic holography or endoholography combines the features of endoscopy and holography. The purpose of endoholographic imaging is to provide the physician with a unique means of extending diagnosis by providing a life-like record of tissue. Endoholographic recording will provide means for microscopic examination of tissue and in some cases may obviate the need to excise specimens for biopsy. In this method holograms which have the unique properties of three-dimensionality large focal depth and high resolution are made with a newly designed endoscope. The endoscope uses a single-mode optical fiber for illumination and single-beam reflection holograms are recorded in close contact with the tissue at the distal end of the endoscope. The holograms are viewed under a microscope. By using the proper combinations of dyes for staining specific tissue types with various wavelengths of laser illumination increased contrast on the cellular level can be obtained. Using dyes such as rose bengal in combination with the 514. 5 nm line of an argon ion laser and trypan blue or methylene blue with the 647. 1 nm line of a krypton ion laser holograms of the stained colon of a dog showed the architecture of the colon''s columnar epithelial cells. It is hoped through chronological study using this method in-vivo an increased understanding of the etiology and pathology of diseases such as Crohn''s diseases colitis proctitis and several different forms of cancer will help to their control. 1.
Sun, Ryan; Bouchard, Matthew B.; Hillman, Elizabeth M. C.
2010-01-01
Camera-based in-vivo optical imaging can provide detailed images of living tissue that reveal structure, function, and disease. High-speed, high resolution imaging can reveal dynamic events such as changes in blood flow and responses to stimulation. Despite these benefits, commercially available scientific cameras rarely include software that is suitable for in-vivo imaging applications, making this highly versatile form of optical imaging challenging and time-consuming to implement. To address this issue, we have developed a novel, open-source software package to control high-speed, multispectral optical imaging systems. The software integrates a number of modular functions through a custom graphical user interface (GUI) and provides extensive control over a wide range of inexpensive IEEE 1394 Firewire cameras. Multispectral illumination can be incorporated through the use of off-the-shelf light emitting diodes which the software synchronizes to image acquisition via a programmed microcontroller, allowing arbitrary high-speed illumination sequences. The complete software suite is available for free download. Here we describe the software’s framework and provide details to guide users with development of this and similar software. PMID:21258475
Optical control of pain in vivo with a photoactive mGlu5 receptor negative allosteric modulator.
Font, Joan; López-Cano, Marc; Notartomaso, Serena; Scarselli, Pamela; Di Pietro, Paola; Bresolí-Obach, Roger; Battaglia, Giuseppe; Malhaire, Fanny; Rovira, Xavier; Catena, Juanlo; Giraldo, Jesús; Pin, Jean-Philippe; Fernández-Dueñas, Víctor; Goudet, Cyril; Nonell, Santi; Nicoletti, Ferdinando; Llebaria, Amadeu; Ciruela, Francisco
2017-04-11
Light-operated drugs constitute a major target in drug discovery, since they may provide spatiotemporal resolution for the treatment of complex diseases (i.e. chronic pain). JF-NP-26 is an inactive photocaged derivative of the metabotropic glutamate type 5 (mGlu 5 ) receptor negative allosteric modulator raseglurant. Violet light illumination of JF-NP-26 induces a photochemical reaction prompting the active-drug's release, which effectively controls mGlu 5 receptor activity both in ectopic expressing systems and in striatal primary neurons. Systemic administration in mice followed by local light-emitting diode (LED)-based illumination, either of the thalamus or the peripheral tissues, induced JF-NP-26-mediated light-dependent analgesia both in neuropathic and in acute/tonic inflammatory pain models. These data offer the first example of optical control of analgesia in vivo using a photocaged mGlu 5 receptor negative allosteric modulator. This approach shows potential for precisely targeting, in time and space, endogenous receptors, which may allow a better management of difficult-to-treat disorders.
Photodynamic therapy for treatment of solid tumors – potential and technical challenges
Huang, Zheng; Xu, Heping; Meyers, Arlen D.; Musani, Ali I.; Wang, Luowei; Tagg, Randall; Barqawi, Al B.; Chen, Yang K.
2008-01-01
Photodynamic therapy (PDT) involves the administration of photosensitizer followed by local illumination with visible light of specific wavelength(s). In the presence of oxygen molecules, the light illumination of photosensitizer can lead to a series of photochemical reactions and consequently the generation of cytotoxic species. The quantity and location of PDT-induced cytotoxic species determine the nature and consequence of PDT. Much progress has been seen in both basic research and clinical application in recent years. Although the majority of approved PDT clinical protocols have primarily been used for the treatment of superficial lesions of both malignant and non-malignant diseases, interstitial PDT for the ablation of deep-seated solid tumors are now being investigated worldwide. The complexity of the geometry and non-homogeneity of solid tumor pose a great challenge on the implementation of minimally invasive interstitial PDT and the estimation of PDT dosimetry. This review will discuss the recent progress and technical challenges of various forms of interstitial PDT for the treatment of parenchymal and/or stromal tissues of solid tumors. PMID:18642969
Systems Health: A Transition from Disease Management Toward Health Promotion.
Shen, Li; Ye, Benchen; Sun, Huimin; Lin, Yuxin; van Wietmarschen, Herman; Shen, Bairong
2017-01-01
To date, most of the chronic diseases such as cancer, cardiovascular disease, and diabetes, are the leading cause of death. Current strategies toward disease treatment, e.g., risk prediction and target therapy, still have limitations for precision medicine due to the dynamic and complex nature of health. Interactions among genetics, lifestyle, and surrounding environments have nonnegligible effects on disease evolution. Thus a transition in health-care area is urgently needed to address the hysteresis of diagnosis and stabilize the increasing health-care costs. In this chapter, we explored new insights in the field of health promotion and introduced the integration of systems theories with health science and clinical practice. On the basis of systems biology and systems medicine, a novel concept called "systems health" was comprehensively advocated. Two types of bioinformatics models, i.e., causal loop diagram and quantitative model, were selected as examples for further illumination. Translational applications of these models in systems health were sequentially discussed. Moreover, we highlighted the bridging of ancient and modern views toward health and put forward a proposition for citizen science and citizen empowerment in health promotion.
Hybrid daylight/light-emitting diode illumination system for indoor lighting.
Ge, Aiming; Qiu, Peng; Cai, Jinlin; Wang, Wei; Wang, Junwei
2014-03-20
A hybrid illumination method using both daylight and light-emitting diodes (LEDs) for indoor lighting is presented in this study. The daylight can be introduced into the indoor space by a panel-integration system. The daylight part and LEDs are combined within a specific luminaire that can provide uniform illumination. The LEDs can be turned on and dimmed through closed-loop control when the daylight illuminance is inadequate. We simulated the illumination and calculated the indoor lighting efficiency of our hybrid daylight and LED lighting system, and compared this with that of LED and fluorescent lighting systems. Simulation results show that the efficiency of the hybrid daylight/LED illumination method is better than that of LED and traditional lighting systems, under the same lighting conditions and lighting time; the method has hybrid lighting average energy savings of T5 66.28%, and that of the LEDs is 41.62%.
NASA Astrophysics Data System (ADS)
Chang, Chia-Yuan; Chen, Shean-Jen
2017-02-01
Conventional temporal focusing-based multiphoton excitation microscopy (TFMPEM) can offer widefield optical sectioning with an axial excitation confinement (AEC) of a few microns. Herein, a developed TFMPEM with a digital micromirror device (DMD), acting as the blazed grating for light spatial dispersion and simultaneous patterned illumination, has been extended to implement spatially modulated illumination at structured frequency and orientation. By implementing the spatially modulated illumination, the beam coverage at the back-focal aperture of the objective lens can be increased. As a result, the AEC can be condensed from 3.0 μm to 1.5 μm in full width at half maximum for a 2-fold enhancement. Furthermore, by using HiLo microscopy with two structured illuminations at the same spatial frequency but different orientation, biotissue images according to the structured illumination with condensed AEC is obviously superior in contrast and scattering suppression.
Effects of color combination and ambient illumination on visual perception time with TFT-LCD.
Lin, Chin-Chiuan; Huang, Kuo-Chen
2009-10-01
An empirical study was carried out to examine the effects of color combination and ambient illumination on visual perception time using TFT-LCD. The effect of color combination was broken down into two subfactors, luminance contrast ratio and chromaticity contrast. Analysis indicated that the luminance contrast ratio and ambient illumination had significant, though small effects on visual perception. Visual perception time was better at high luminance contrast ratio than at low luminance contrast ratio. Visual perception time under normal ambient illumination was better than at other ambient illumination levels, although the stimulus color had a confounding effect on visual perception time. In general, visual perception time was better for the primary colors than the middle-point colors. Based on the results, normal ambient illumination level and high luminance contrast ratio seemed to be the optimal choice for design of workplace with video display terminals TFT-LCD.
NASA Astrophysics Data System (ADS)
Gao, Jin-gui; Zhao, Hong-gang; Luo, Lai-peng
2017-04-01
In this paper, MJ3310A band saw machine as the research object, through the Beijing VIBSYS vibration signal acquisition and analysis software illumination value analysis, analysis of different circumstances to find good and crack band saw blade illumination value of the law. The results show that the illuminance of the cracked band saw blade is significantly higher than that of the complete band saw blade illumination value. Under the optimum working conditions, if the band saw blade illumination value exceeds 286 Lux, it can be determined that the band saw blade has at least one crack length greater than 1.68 mm Of the defects, the need for timely replacement band saw blade. So as to rational use of band saw blade, band saw blade on-line fault diagnosis provides a technical basis.
Influence of illuminants on the color distribution of shade guides.
Park, Ji-Hoon; Lee, Yong-Keun; Lim, Bum-Soon
2006-12-01
Although a shade tab in a shade guide is matched to a natural tooth in the order of value, hue, and chroma, there are limited data on the color distribution of currently available shade guides sorted by these 3 parameters. Furthermore, spectrophotometric color measurements of shade tabs differ depending on the standard illuminant employed. The purpose of this study was to determine the color distributions of 2 shade guides in value (CIE L( *)), chroma (C( *)(ab)) and hue angle (h(o)) scale relative to the standard illuminants D(65), A, and F2. Color of shade tabs (n=36) from 2 shade guides (Vita Lumin and Chromascop) were measured, and the distributions for CIE L( *), C( *)(ab) and h(o) values were compared. Color differences of shade tabs depending on the illuminant were calculated. The distributions of the ratios of CIE L( *) and C( *)(ab) values of each shade tab compared with the lowest value tab or the lowest chroma tab were determined. The data for the value, chroma, and hue angle within each shade guide were analyzed with a 2-way ANOVA with the factors of shade designation and type of illuminant (alpha=.05). Color difference caused by change of illuminant was analyzed with a 2-way ANOVA with the factors of shade designation and pair of illuminants compared (alpha=.05). The Scheffe multiple comparison test was performed as a post hoc test. CIE L( *), C( *)(ab) and h(o) values were influenced by shade designation and type of illuminant in both shade guides. Color difference caused by change of the illuminant was influenced by the shade designation and pair of illuminants compared. The order of mean color differences of 16 Vita Lumin shade tabs by pairs of illuminants compared was as follows: DeltaE( *)(ab) (D(65)/F2) = 1.63
Freudenmann, Roland W.; Lepping, Peter
2009-01-01
Summary: This papers aims at familiarizing psychiatric and nonpsychiatric readers with delusional infestation (DI), also known as delusional parasitosis. It is characterized by the fixed belief of being infested with pathogens against all medical evidence. DI is no single disorder but can occur as a delusional disorder of the somatic type (primary DI) or secondary to numerous other conditions. A set of minimal diagnostic criteria and a classification are provided. Patients with DI pose a truly interdisciplinary problem to the medical system. They avoid psychiatrists and consult dermatologists, microbiologists, or general practitioners but often lose faith in professional medicine. Epidemiology and history suggest that the imaginary pathogens change constantly, while the delusional theme “infestation” is stable and ubiquitous. Patients with self-diagnosed “Morgellons disease” can be seen as a variation of this delusional theme. For clinicians, clinical pathways for efficient diagnostics and etiology-specific treatment are provided. Specialized outpatient clinics in dermatology with a liaison psychiatrist are theoretically best placed to provide care. The most intricate problem is to engage patients in psychiatric therapy. In primary DI, antipsychotics are the treatment of choice, according to limited but sufficient evidence. Pimozide is no longer the treatment of choice for reasons of drug safety. Future research should focus on pathophysiology and the neural basis of DI, as well as on conclusive clinical trials, which are widely lacking. Innovative approaches will be needed, since otherwise patients are unlikely to adhere to any study protocol. PMID:19822895
Slow updating of the achromatic point after a change in illumination
Lee, R. J.; Dawson, K. A.; Smithson, H. E.
2015-01-01
For a colour constant observer, the colour appearance of a surface is independent of the spectral composition of the light illuminating it. We ask how rapidly colour appearance judgements are updated following a change in illumination. We obtained repeated binary colour classifications for a set of stimuli defined by their reflectance functions and rendered under either sunlight or skylight. We used these classifications to derive boundaries in colour space that identify the observer’s achromatic point. In steady-state conditions of illumination, the achromatic point lay close to the illuminant chromaticity. In our experiment the illuminant changed abruptly every 21 seconds (at the onset of every 10th trial), allowing us to track changes in the achromatic point that were caused by the cycle of illuminant changes. In one condition, the test reflectance was embedded in a spatial pattern of reflectance samples under consistent illumination. The achromatic point migrated across colour space between the chromaticities of the steady-state achromatic points. This update took several trials rather than being immediate. To identify the factors that governed perceptual updating of appearance judgements we used two further conditions, one in which the test reflectance was presented in isolation and one in which the surrounding reflectances were rendered under an inconsistent and unchanging illumination. Achromatic settings were not well predicted by the information available from scenes at a single time-point. Instead the achromatic points showed a strong dependence on the history of chromatic samples. The strength of this dependence differed between observers and was modulated by the spatial context. PMID:22275468
Pakkala, T; Kuusela, L; Ekholm, M; Wenzel, A; Haiter-Neto, F; Kortesniemi, M
2012-01-01
In clinical practice, digital radiographs taken for caries diagnostics are viewed on varying types of displays and usually in relatively high ambient lighting (room illuminance) conditions. Our purpose was to assess the effect of room illuminance and varying display types on caries diagnostic accuracy in digital dental radiographs. Previous studies have shown that the diagnostic accuracy of caries detection is significantly better in reduced lighting conditions. Our hypothesis was that higher display luminance could compensate for this in higher ambient lighting conditions. Extracted human teeth with approximal surfaces clinically ranging from sound to demineralized were radiographed and evaluated by 3 observers who detected carious lesions on 3 different types of displays in 3 different room illuminance settings ranging from low illumination, i.e. what is recommended for diagnostic viewing, to higher illumination levels corresponding to those found in an average dental office. Sectioning and microscopy of the teeth validated the presence or absence of a carious lesion. Sensitivity, specificity and accuracy were calculated for each modality and observer. Differences were estimated by analyzing the binary data assuming the added effects of observer and modality in a generalized linear model. The observers obtained higher sensitivities in lower illuminance settings than in higher illuminance settings. However, this was related to a reduction in specificity, which meant that there was no significant difference in overall accuracy. Contrary to our hypothesis, there were no significant differences between the accuracy of different display types. Therefore, different displays and room illuminance levels did not affect the overall accuracy of radiographic caries detection. Copyright © 2012 S. Karger AG, Basel.
Illuminated push-button switch
NASA Technical Reports Server (NTRS)
Iwagiri, T.
1983-01-01
An illuminated push-button switch is described. It is characterized by the fact that is consists of a switch group, an operator button opening and closing the switch group, and a light-emitting element which illuminates the face of the operator button.
Gokce, Hasan Suat; Piskin, Bulent; Ceyhan, Dogan; Gokce, Sila Mermut; Arisan, Volkan
2010-03-01
The lighting conditions of the environment and visual deficiencies such as red-green color vision deficiency affect the clinical shade matching performance of dental professionals. The purpose of this study was to evaluate the shade matching performance of normal and color vision-deficient dental professionals with standard daylight and tungsten illuminants. Two sets of porcelain disc replicas of 16 shade guide tabs (VITA Lumin) were manufactured to exact L*a*b* values by using a colorimeter. Then these twin porcelain discs (13 mm x 2.4 mm) were mixed up and placed into a color-matching cabinet that standardized the lighting conditions for the observation tests. Normal and red-green color vision-deficient dental professionals were asked to match the 32 porcelain discs using standard artificial daylight D65 (high color temperature) and tungsten filament lamp light (T) (low color temperature) illuminants. The results were analyzed by repeated-measures ANOVA and paired and independent samples t tests for the differences between dental professionals and differences between the illuminants (alpha=.05). Regarding the sum of the correct shade match scores of all observations with both illuminants, the difference between normal vision and red-green color vision-deficient dental professional groups was not statistically significant (F=4.132; P=.054). However, the correct shade match scores of each group were significantly different for each illuminant (P<.005). The correct shade matching scores of normal color vision dental professionals were significantly higher with D65 illuminant (t=7.004; P<.001). Color matching scores of red-green color vision-deficient dental professionals (approximately 5.7 more pairs than with D65) were significantly higher with T illuminant (t=5.977; P<.001). CONCLUSIONS.: Within the limitations of this study, the shade matching performance of dental professionals was affected by color vision deficiency and the color temperature of the illuminant. The color vision-deficient group was notably unsuccessful with the D65 illuminant in shade matching. In contrast, there was a significant increase in the shade matching performance of the color vision-deficient group with T illuminant. The lower color temperature illuminant dramatically decreased the normal color vision groups' correct shade matching score. (c) 2010 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.
IR Image upconversion using band-limited ASE illumination fiber sources.
Maestre, H; Torregrosa, A J; Capmany, J
2016-04-18
We study the field-of-view (FOV) of an upconversion imaging system that employs an Amplified Spontaneous Emission (ASE) fiber source to illuminate a transmission target. As an intermediate case between narrowband laser and thermal illumination, an ASE fiber source allows for higher spectral intensity than thermal illumination and still keeps a broad wavelength spectrum to take advantage of an increased non-collinear phase-matching angle acceptance that enlarges the FOV of the upconversion system when compared to using narrowband laser illumination. A model is presented to predict the angular acceptance of the upconverter in terms of focusing and ASE spectral width and allocation. The model is experimentally checked in case of 1550-630 nm upconversion.
Even illumination in total internal reflection fluorescence microscopy using laser light.
Fiolka, R; Belyaev, Y; Ewers, H; Stemmer, A
2008-01-01
In modern fluorescence microscopy, lasers are a widely used source of light, both for imaging in total internal reflection and epi-illumination modes. In wide-field imaging, scattering of highly coherent laser light due to imperfections in the light path typically leads to nonuniform illumination of the specimen, compromising image analysis. We report the design and construction of an objective-launch total internal reflection fluorescence microscopy system with excellent evenness of specimen illumination achieved by azimuthal rotation of the incoming illuminating laser beam. The system allows quick and precise changes of the incidence angle of the laser beam and thus can also be used in an epifluorescence mode. 2007 Wiley-Liss, Inc
Improvement of illumination uniformity for LED flat panel light by using micro-secondary lens array.
Lee, Hsiao-Wen; Lin, Bor-Shyh
2012-11-05
LED flat panel light is an innovative lighting product in recent years. However, current flat panel light products still contain some drawbacks, such as narrow lighting areas and hot spots. In this study, a micro-secondary lens array technique was proposed and applied for the design of the light guide surface to improve the illumination uniformity. By using the micro-secondary lens array, the candela distribution of the LED flat panel light can be adjusted to similar to batwing distribution to improve the illumination uniformity. The experimental results show that the enhancement of the floor illumination uniformity is about 61%, and that of the wall illumination uniformity is about 20.5%.
Scattering and absorption control in biocompatible fibers towards equalized photobiomodulation.
George, J; Haghshenas, H; d'Hemecourt, D; Zhu, W; Zhang, L; Sorger, V
2017-03-01
Transparent tissue scaffolds enable illumination of growing tissue to accelerate cell proliferation and improve other cell functions through photobiomodulation. The biphasic dose response of cells exposed to photobiomodulating light dictates that the illumination be evenly distributed across the scaffold such that the cells are neither under nor over exposed to light. However, equalized illumination has not been sufficiently addressed. Here we analyze and experimentally demonstrate spatially equalizing illumination by three methods, namely: engineered surface scattering, reflection by a gold mirror, and traveling-waves in a ring mesh. Our results show that nearly equalized illumination is achievable by controlling the light scattering-to-loss ratio. This demonstration furthers opportunities for dose-optimized photobiomodulation in tissue regeneration.
Design of illumination system in ring field capsule endoscope
NASA Astrophysics Data System (ADS)
Jeng, Wei-De; Mang, Ou-Yang; Chen, Yu-Ta; Wu, Ying-Yi
2011-03-01
This paper is researching about the illumination system in ring field capsule endoscope. It is difficult to obtain the uniform illumination on the observed object because the light intensity of LED will be changed along its angular displacement and same as luminous intensity distribution curve. So we use the optical design software which is Advanced Systems Analysis Program (ASAP) to build a photometric model for the optimal design of LED illumination system in ring field capsule endoscope. In this paper, the optimal design of illumination uniformity in the ring field capsule endoscope is from origin 0.128 up to optimum 0.603 and it would advance the image quality of ring field capsule endoscope greatly.
Chen, Yibing; Ogata, Taiki; Ueyama, Tsuyoshi; Takada, Toshiyuki; Ota, Jun
2018-01-01
Machine vision is playing an increasingly important role in industrial applications, and the automated design of image recognition systems has been a subject of intense research. This study has proposed a system for automatically designing the field-of-view (FOV) of a camera, the illumination strength and the parameters in a recognition algorithm. We formulated the design problem as an optimisation problem and used an experiment based on a hierarchical algorithm to solve it. The evaluation experiments using translucent plastics objects showed that the use of the proposed system resulted in an effective solution with a wide FOV, recognition of all objects and 0.32 mm and 0.4° maximal positional and angular errors when all the RGB (red, green and blue) for illumination and R channel image for recognition were used. Though all the RGB illumination and grey scale images also provided recognition of all the objects, only a narrow FOV was selected. Moreover, full recognition was not achieved by using only G illumination and a grey-scale image. The results showed that the proposed method can automatically design the FOV, illumination and parameters in the recognition algorithm and that tuning all the RGB illumination is desirable even when single-channel or grey-scale images are used for recognition. PMID:29786665
Chen, Yibing; Ogata, Taiki; Ueyama, Tsuyoshi; Takada, Toshiyuki; Ota, Jun
2018-05-22
Machine vision is playing an increasingly important role in industrial applications, and the automated design of image recognition systems has been a subject of intense research. This study has proposed a system for automatically designing the field-of-view (FOV) of a camera, the illumination strength and the parameters in a recognition algorithm. We formulated the design problem as an optimisation problem and used an experiment based on a hierarchical algorithm to solve it. The evaluation experiments using translucent plastics objects showed that the use of the proposed system resulted in an effective solution with a wide FOV, recognition of all objects and 0.32 mm and 0.4° maximal positional and angular errors when all the RGB (red, green and blue) for illumination and R channel image for recognition were used. Though all the RGB illumination and grey scale images also provided recognition of all the objects, only a narrow FOV was selected. Moreover, full recognition was not achieved by using only G illumination and a grey-scale image. The results showed that the proposed method can automatically design the FOV, illumination and parameters in the recognition algorithm and that tuning all the RGB illumination is desirable even when single-channel or grey-scale images are used for recognition.
Color constancy influenced by unnatural spatial structure.
Mizokami, Yoko; Yaguchi, Hirohisa
2014-04-01
The recognition of spatial structures is important for color constancy because we cannot identify an object's color under different illuminations without knowing which space it is in and how that space is illuminated. To show the importance of the natural structure of environments on color constancy, we investigated the way in which color appearance was affected by unnatural viewing conditions in which a spatial structure was distorted. Observers judged the color of a test patch placed in the center of a small room illuminated by white or reddish lights, as well as two rooms illuminated by white and reddish light, respectively. In the natural viewing condition, an observer saw the room(s) through a viewing window, whereas in an unnatural viewing condition, the scene structure was scrambled by a kaleidoscope-type viewing box. Results of single room condition with one illuminant color showed little difference in color constancy between the two viewing conditions. However, it decreased in the two-rooms condition with a more complex arrangement of space and illumination. The patch's appearance under the unnatural viewing condition was more influenced by simultaneous contrast than its appearance under the natural viewing condition. It also appears that color appearance under white illumination is more stable compared to that under reddish illumination. These findings suggest that natural spatial structure plays an important role for color constancy in a complex environment.
Biological Effects Of Artificial Illumination
NASA Astrophysics Data System (ADS)
Corth, Richard
1980-10-01
We are increasingly being warned of the possible effects of so called "polluted" light, that is light that differs in spectral content from that of sunlight. We should be concerned, we are told, because all animals and plants have evolved under this natural daylight and therefore any difference between that illuminant and the artificial illuminants that are on the market today, is suspect. The usual presentation of the differences between the sunlight and the artificial illuminants are as shown in Figure 1. Here we are shown the spectral power distribution of sunlight and Cool White fluorescent light. The spectral power distributions of each have been normalized to some convenient wavelength so that each can be seen and easily compared on the same figure. But this presentation is misleading for one does not experience artificial illuminants at the same intensity as one experiences sunlight. Sunlight intensities are ordinarily found to be in the 8000 to 10,000 footcandle range whereas artificial illuminants are rarely experienced at intensity levels greater than 100 footcandles. Therefore a representative difference between the two types of illumination conditions is more accurately represented as in Figure 2. Thus if evolutionary adaptations require that humans and other animals be exposed to sunlight to ensure wellbeing, it is clear that one must be exposed to sunlight intensities. It is not feasible to expect that artificially illuminated environments will be lit to the same intensity as sunlight
Improved illumination system of laparoscopes using an aspherical lens array.
Wu, Rengmao; Qin, Yi; Hua, Hong
2016-06-01
The current fiber-based illumination systems of laparoscopes are unable to uniformly illuminate a large enough area in abdomen due to the limited numerical aperture (NA) of the fiber bundle. Most energy is concentrated in a small region at the center of the illumination area. This limitation becomes problematic in laparoscopes which require capturing a wide field of view. In this paper, we propose an aspherical lens array which is used to direct the outgoing rays from the fiber bundle of laparoscope to produce a more uniformly illuminated, substantially larger field coverage than standalone fiber source. An intensity feedback method is developed to design the aspherical lens unit for extended non-Lambertian sources, which is the key to the design of this lens array. By this method, the lens unit is obtained after only one iteration, and the lens array is constructed by Boolean operation. Then, the ray-tracing technique is used to verify the design. Further, the lens array is fabricated and experimental tests are performed. The results clearly show that the well-illuminated area is increased to about 0.107m(2) from 0.02m(2) (about 5x larger than a standard fiber illumination source). More details of the internal organs can be clearly observed under this improved illumination condition, which also reflects the significant improvement in the optical performance of the laparoscope.
Yi, Jizheng; Mao, Xia; Chen, Lijiang; Xue, Yuli; Rovetta, Alberto; Caleanu, Catalin-Daniel
2015-01-01
Illumination normalization of face image for face recognition and facial expression recognition is one of the most frequent and difficult problems in image processing. In order to obtain a face image with normal illumination, our method firstly divides the input face image into sixteen local regions and calculates the edge level percentage in each of them. Secondly, three local regions, which meet the requirements of lower complexity and larger average gray value, are selected to calculate the final illuminant direction according to the error function between the measured intensity and the calculated intensity, and the constraint function for an infinite light source model. After knowing the final illuminant direction of the input face image, the Retinex algorithm is improved from two aspects: (1) we optimize the surround function; (2) we intercept the values in both ends of histogram of face image, determine the range of gray levels, and stretch the range of gray levels into the dynamic range of display device. Finally, we achieve illumination normalization and get the final face image. Unlike previous illumination normalization approaches, the method proposed in this paper does not require any training step or any knowledge of 3D face and reflective surface model. The experimental results using extended Yale face database B and CMU-PIE show that our method achieves better normalization effect comparing with the existing techniques.
Swanson, William H; Dul, Mitchell W; Horner, Douglas G; Liu, Tiffany; Tran, Irene
2014-01-20
To develop perimetric stimuli for which sensitivities are more resistant to reduced retinal illumination than current clinical perimeters. Fifty-four people free of eye disease were dilated and tested monocularly. For each test, retinal illumination was attenuated with neutral density (ND) filters, and a standard adaptation model was fit to derive mean and SEM for the adaptation parameter (NDhalf). For different stimuli, t-tests on NDhalf were used to assess significance of differences in consistency with Weber's law. Three experiments used custom Gaussian-windowed contrast sensitivity perimetry (CSP). Experiment 1 used CSP-1, with a Gaussian temporal pulse, a spatial frequency of 0.375 cyc/deg (cpd), and SD of 1.5°. Experiment 1 also used the Humphrey Matrix perimeter, with the N-30 test using 0.25 cpd and 25 Hz flicker. Experiment 2 used a rectangular temporal pulse, SDs of 0.25° and 0.5°, and spatial frequencies of 0.0 and 1.0 cpd. Experiment 3 used CSP-2, with 5-Hz flicker, SDs from 0.5° to 1.8°, and spatial frequencies from 0.14 to 0.50 cpd. In Experiment 1, CSP-1 was more consistent with Weber's law (NDhalf ± SEM = 1.86 ± 0.08 log unit) than N-30 (NDhalf = 1.03 ± 0.03 log unit; t > 9, P < 0.0001). All stimuli used in Experiments 2 and 3 had comparable consistency with Weber's law (NDhalf = 1.49-1.69 log unit; t < 2). Perimetric sensitivities were consistent with Weber's law when higher temporal frequencies were avoided.
Evaluation of the cost-effectiveness of illumination as a safety treatment at rural intersections.
DOT National Transportation Integrated Search
2016-09-01
This research study seeks to improve current understanding of the relationship between rural intersection safety and different illumination levels. It uses three parallel studies: a survey of rural intersection illumination practices among US state d...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Surface Installations § 77.207 Illumination. Illumination sufficient to provide safe working conditions shall be...
Intermittent illumination increases biophotolytic hydrogen yield by Anabaena cylindrica
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jeffries, T.W.; Leach, K.L.
Intermittent illumination increased H/sub 2/ and C/sub 2/H/sub 4/ yields per unit of light from growing cells and from nitrogen-starved cells by 1.7- and 1.35-fold, respectively, as compared with continuous illumination.
NASA Astrophysics Data System (ADS)
Tegegne, Z. G.; Viana, C.; Polleux, J. L.; Grzeskowiak, M.; Richalot, E.
2016-03-01
This paper demonstrates the experimental study of edge and top illuminated SiGe phototransistors (HPT) implemented using the existing industrial SiGe2RF Telefunken GmbH BiCMOS technology for opto-microwave (OM) applications using 850nm Multi-Mode Fibers (MMF). Its technology and structure are described. Two different optical window size HPTs with top illumination (5x5μm2, 10x10μm2) and an edge illuminated HPTs having 5μm x5μm size are presented and compared. A two-step post fabrication process was used to create an optical access on the edge of the HPT for lateral illumination with a lensed MMF through simple polishing and dicing techniques. We perform Opto-microwave Scanning Near-field Optical Microscopy (OM-SNOM) analysis on edge and top illuminated HPTs in order to observe the fastest and the highest sensitive regions of the HPTs. This analysis also allows understanding the parasitic effect from the substrate, and thus draws a conclusion on the design aspect of SiGe/Si HPT. A low frequency OM responsivity of 0.45A/W and a cutoff frequency, f-3dB, of 890MHz were measured for edge illuminated HPT. Compared to the top illuminated HPT of the same size, the edge illuminated HPT improves the f-3dB by a factor of more than two and also improves the low frequency responsivity by a factor of more than four. These results demonstrate that a simple etched HPT is still enough to achieve performance improvements compared to the top illuminated HPT without requiring a complex coupling structure. Indeed, it also proves the potential of edge coupled SiGe HPT in the ultra-low-cost silicon based optoelectronics circuits with a new approach of the optical packaging and system integration to 850nm MMF.
The Influence of Very Low Illumination on the Postural Sway of Young and Elderly Adults
Rugelj, Darja; Gomišček, Gregor; Sevšek, France
2014-01-01
The purpose of the present study was to evaluate the influence of very low ambient illumination and complete darkness on the postural sway of young and elderly adults. Eighteen healthy young participants aged 23.8±1.5 years and 26 community-dwelling elderly aged 69.8±5.6 years were studied. Each participant performed four tests while standing on a force platform in the following conditions: in normal light (215 lx) with open eyes and with closed eyes, in very low illumination (0.25 lx) with open eyes, and in complete darkness with open eyes. The sequences of the tests in the altered visual conditions were determined by random blocs. Postural sway was assessed by means of the force platform measurements. The centre of pressure variables: the medio-lateral and antero-posterior path lengths, mean velocities, sway areas, and fractal dimensions were analysed. Very low illumination resulted in a statistically significant increase in postural sway in both the young and elderly groups compared to normal light, although the increase was significantly smaller than those observed in the eyes closed and complete darkness condition, and no significant effects of illumination on fractal dimensions were detected. The gains of the sways in the very low or no illumination conditions relative to the normal light condition were significantly larger in the group of young participants than in the group of elderly participants (up to 50% and 25%, respectively). However, the response patterns to changes in illumination were similar in the young and elderly participants, with the exception of the short-range fractal dimension of the medio-lateral sway. In conclusion, very low illumination resulted in increased postural sway compared to normal illumination; however, in the closed eye and complete darkness conditions, postural sway was significantly higher than in the very low illumination condition regardless of the age of the participants. PMID:25084015
Portable system to luminaries characterization
NASA Astrophysics Data System (ADS)
Tecpoyotl-Torres, M.; Vera-Dimas, J. G.; Koshevaya, S.; Escobedo-Alatorre, J.; Cisneros-Villalobos, L.; Sanchez-Mondragon, J.
2014-09-01
For illumination sources designers is important to know the illumination distribution of their products. They can use several viewers of IES files (standard file format determined by Illuminating Engineering Society). This files are necessary not only know the distribution of illumination, but also to plain the construction of buildings by means of specialized softwares, such as Autodesk Revit. In this paper, a complete portable system for luminaries' characterization is given. The components of the systems are: Irradiance profile meter, which can generate photometry of luminaries of small sizes which covers indoor illumination requirements and luminaries for general areas. One of the meteŕs attributes is given by the color sensor implemented, which allows knowing the color temperature of luminary under analysis. The Graphic Unit Interface (GUI) has several characteristics: It can control the meter, acquires the data obtained by the sensor and graphs them in 2D under Cartesian and polar formats or 3D, in Cartesian format. The graph can be exported to png, jpg, or bmp formats, if necessary. These remarkable characteristics differentiate this GUI. This proposal can be considered as a viable option for enterprises of illumination design and manufacturing, due to the relatively low investment level and considering the complete illumination characterization provided.
NASA Astrophysics Data System (ADS)
Liang, Wenxuan; Murari, Kartikeya; Zhang, Yuying; Chen, Yongping; Li, Ming-Jun; Li, Xingde
2012-02-01
We compare the illumination uniformity and the associated effects of the spiral and Lissajous scanning patterns that are commonly used in an endomicroscope. Theoretical analyses and numerical simulations were first performed to quantitatively investigate the area illumination density in the spiral scanning pattern. The results revealed the potential problem of manifest photodamage due to the very high illumination density in the center of the spiral scan. Similar analyses of the Lissajous scanning pattern, which can be conveniently implemented on the same endomicroscope with no hardware modifications, showed a more uniform illumination density with about an 80-fold reduction in the peak illumination density. To underscore the benefit offered by the improved illumination uniformity, we conducted in vitro two-photon fluorescence imaging of cultured cells stained with a LIVE/DEAD viability assay using our home-built, fiber-optic, two-channel endomicroscopy system. Both the spiral and the Lissajous scans were implemented. Our experimental results showed that cells near the spiral scan center experienced obvious photodamage, whereas cells remained alive over the entire region under the Lissajous beam scanning, confirming the predicted advantage offered by the Lissajous scan over this spiral scan in an endomicroscopy setting.
NASA Astrophysics Data System (ADS)
Zhuang, Zhenfeng; Thibault, Simon
2017-11-01
One of the key issues in conventional wide-angle lenses is the well-known cosine-fourth power law problem causing the illumination falloff at its image space. This paper explores methods of improving illumination in the image space in panomorph lenses. By tracing skew rays within the defined field of view and pupil diameter, we obtained the actual position of the three-dimensional pupil model of the entrance pupil (EP) and exit pupil (XP). Based on the law of irradiance transport conservation, the relation between the area of the EP projection and illumination in the image space is derived to investigate the factors affecting the illumination on the peripheral field. A panomorph lens has been optimized as an example by providing a self-defined operation in the optimization process. The characteristic of the EP and XP in panomorph lenses is qualitatively analyzed. Compared with the conventional design method, the proposed design strategy can enhance the illumination with and without polarized light based on qualitatively evaluating the area of projected EP. It is demonstrated that this method enables the enhancement of the illumination without additional film coating.
Shimakawa, Ginga; Miyake, Chikahiro
2018-03-08
Oxygenic phototrophs are vulnerable to damage by reactive oxygen species (ROS) that are produced in photosystem I (PSI) by excess photon energy over the demand of photosynthetic CO 2 assimilation. In plant leaves, repetitive short-pulse (rSP) illumination produces ROS to inactivate PSI. The production of ROS is alleviated by oxidation of the reaction center chlorophyll in PSI, P700, during the illumination with the short-pulse light, which is supported by flavodiiron protein (FLV). In this study, we found that in the cyanobacterium Synechocystis sp. PCC 6803 P700 was oxidized and PSI was not inactivated during rSP illumination even in the absence of FLV. Conversely, the mutant deficient in respiratory terminal oxidases was impaired in P700 oxidation during the illumination with the short-pulse light to suffer from photo-oxidative damage in PSI. Interestingly, the other cyanobacterium Synechococcus sp. PCC 7002 could not oxidize P700 without FLV during rSP illumination. These data indicate that respiratory terminal oxidases are critical to protect PSI from ROS damage during rSP illumination in Synechocystis sp. PCC 6803 but not Synechococcus sp. PCC 7002.
Lunar South Pole Illumination: Review, Reassessment, and Power System Implications
NASA Technical Reports Server (NTRS)
Fincannon, James
2007-01-01
This paper reviews past analyses and research related to lunar south pole illumination and presents results of independent illumination analyses using an analytical tool and a radar digital elevation model. The analysis tool enables assessment at most locations near the lunar poles for any time and any year. Average illumination fraction, energy storage duration, solar/horizon terrain elevation profiles and illumination fraction profiles are presented for various highly illuminated sites which have been identified for manned or unmanned operations. The format of the data can be used by power system designers to develop mass optimized solar and energy storage systems. Data are presented for the worse case lunar day (a critical power planning bottleneck) as well as three lunar days during lunar south pole winter. The main site under consideration by present lunar mission planners (on the Crater Shackleton rim) is shown to have, for the worse case lunar day, a 0.71 average illumination fraction and 73 to 117 hours required for energy storage (depending on power system type). Linking other sites and including towers at either site are shown to not completely eliminate the need for energy storage.
Liu, Chao; Gu, Jinwei
2014-01-01
Classifying raw, unpainted materials--metal, plastic, ceramic, fabric, and so on--is an important yet challenging task for computer vision. Previous works measure subsets of surface spectral reflectance as features for classification. However, acquiring the full spectral reflectance is time consuming and error-prone. In this paper, we propose to use coded illumination to directly measure discriminative features for material classification. Optimal illumination patterns--which we call "discriminative illumination"--are learned from training samples, after projecting to which the spectral reflectance of different materials are maximally separated. This projection is automatically realized by the integration of incident light for surface reflection. While a single discriminative illumination is capable of linear, two-class classification, we show that multiple discriminative illuminations can be used for nonlinear and multiclass classification. We also show theoretically that the proposed method has higher signal-to-noise ratio than previous methods due to light multiplexing. Finally, we construct an LED-based multispectral dome and use the discriminative illumination method for classifying a variety of raw materials, including metal (aluminum, alloy, steel, stainless steel, brass, and copper), plastic, ceramic, fabric, and wood. Experimental results demonstrate its effectiveness.
Validation of an inexpensive test illuminant for aeromedical color vision screening.
DOT National Transportation Integrated Search
1993-09-01
An inexpensive illuminant for color vision screening suggested by the NRC-NAS Committee on Vision was evaluated as a substitute for the Macbeth Easel Lamp. The Macbeth Easel Lamp is the recommended illuminant for pseudoisochromatic plate tests used i...
IODC 2014 Illumination design problem: the Cinderella Lamp
NASA Astrophysics Data System (ADS)
Cassarly, William J.
2014-12-01
For the 3rd time, the International Optical Design Conference (IODC) included an Illumination Design contest. This year, the contest involved designing the illuminator to project the 1950 Walt Disney "Cinderella" movie using a box of optical knick-knacks. The goal of the problem was to provide the highest screen lumens with greater than 30% uniformity. There were 12 entries from 3 different countries. Three different commercial optical/illumination design packages were used. The winning solution, provided by Alois Herkommer, provided 371 screen lumens.
2010-11-01
Connecting the Medtronic MAST Quadrant Illumination System, Radiance Illumination System, or Radiance X Illumination System--all of which are specialized fiberoptic light cables used with the company's minimally invasive spinal products--to a high-power surgical light source significantly increases the risk of patient burns. Hospitals should ensure that the products are used only with 100 W light sources and 5 mm light cables, as prescribed in the product labeling.
Wide-field airborne laser diode array illuminator: demonstration results
NASA Astrophysics Data System (ADS)
Suiter, H. R.; Holloway, J. H., Jr.; Tinsley, K. R.; Pham, C. N.; Kloess, E. C., III; Witherspoon, N. H.; Stetson, S.; Crosby, F.; Nevis, A.; McCarley, K. A.; Seales, T. C.
2005-06-01
The Airborne Littoral Reconnaissance Technology (ALRT) program has successfully demonstrated the Wide-Field Airborne Laser Diode Array Illuminator (ALDAI-W). This illuminator is designed to illuminate a large area from the air with limited power, weight, and volume. A detection system, of which the ALDAI-W is a central portion, is capable of detecting surface-laid minefields in absolute darkness, extending the allowed mission times to night operations. This will be an overview report, giving processing results and suggested paths for additional development.
Allende, Maria L.; Cook, Emily K.; Larman, Bridget C.; Nugent, Adrienne; Brady, Jacqueline M.; Golebiowski, Diane; Sena-Esteves, Miguel; Tifft, Cynthia J.
2018-01-01
Sandhoff disease, one of the GM2 gangliosidoses, is a lysosomal storage disorder characterized by the absence of β-hexosaminidase A and B activity and the concomitant lysosomal accumulation of its substrate, GM2 ganglioside. It features catastrophic neurodegeneration and death in early childhood. How the lysosomal accumulation of ganglioside might affect the early development of the nervous system is not understood. Recently, cerebral organoids derived from induced pluripotent stem (iPS) cells have illuminated early developmental events altered by disease processes. To develop an early neurodevelopmental model of Sandhoff disease, we first generated iPS cells from the fibroblasts of an infantile Sandhoff disease patient, then corrected one of the mutant HEXB alleles in those iPS cells using CRISPR/Cas9 genome-editing technology, thereby creating isogenic controls. Next, we used the parental Sandhoff disease iPS cells and isogenic HEXB-corrected iPS cell clones to generate cerebral organoids that modeled the first trimester of neurodevelopment. The Sandhoff disease organoids, but not the HEXB-corrected organoids, accumulated GM2 ganglioside and exhibited increased size and cellular proliferation compared with the HEXB-corrected organoids. Whole-transcriptome analysis demonstrated that development was impaired in the Sandhoff disease organoids, suggesting that alterations in neuronal differentiation may occur during early development in the GM2 gangliosidoses. PMID:29358305
Economic value evaluation in disease management programs.
Magnezi, Racheli; Reicher, Sima; Shani, Mordechai
2008-05-01
Chronic disease management has been a rapidly growing entity in the 21st century as a strategy for managing chronic illnesses in large populations. However, experience has shown that disease management programs have not been able to demonstrate their financial value. The objectives of disease management programs are to create quality benchmarks, such as principles and guidelines, and to establish a uniform set of metrics and a standardized methodology for evaluating them. In order to illuminate the essence of disease management and its components, as well as the complexity and the problematic nature of performing economic calculations of their profitability and value, we collected data from several reports that dealt with the economic intervention of disease management programs. The disease management economic evaluation is composed of a series of steps, including the following major categories: data/information technology, information generation, assessment/recommendations, actionable customer plans, and program assessment/reassessment. We demonstrate the elements necessary for economic analysis. Disease management is one of the most innovative tools in the managed care environment and is still in the process of being defined. Therefore, objectives should include the creation of quality measures, such as principles and guidelines, and the establishment of a uniform set of metrics and a standardized methodology for evaluating them.
Allende, Maria L; Cook, Emily K; Larman, Bridget C; Nugent, Adrienne; Brady, Jacqueline M; Golebiowski, Diane; Sena-Esteves, Miguel; Tifft, Cynthia J; Proia, Richard L
2018-03-01
Sandhoff disease, one of the GM2 gangliosidoses, is a lysosomal storage disorder characterized by the absence of β-hexosaminidase A and B activity and the concomitant lysosomal accumulation of its substrate, GM2 ganglioside. It features catastrophic neurodegeneration and death in early childhood. How the lysosomal accumulation of ganglioside might affect the early development of the nervous system is not understood. Recently, cerebral organoids derived from induced pluripotent stem (iPS) cells have illuminated early developmental events altered by disease processes. To develop an early neurodevelopmental model of Sandhoff disease, we first generated iPS cells from the fibroblasts of an infantile Sandhoff disease patient, then corrected one of the mutant HEXB alleles in those iPS cells using CRISPR/Cas9 genome-editing technology, thereby creating isogenic controls. Next, we used the parental Sandhoff disease iPS cells and isogenic HEXB -corrected iPS cell clones to generate cerebral organoids that modeled the first trimester of neurodevelopment. The Sandhoff disease organoids, but not the HEXB -corrected organoids, accumulated GM2 ganglioside and exhibited increased size and cellular proliferation compared with the HEXB -corrected organoids. Whole-transcriptome analysis demonstrated that development was impaired in the Sandhoff disease organoids, suggesting that alterations in neuronal differentiation may occur during early development in the GM2 gangliosidoses.
Patients, persons or partners? Involving those with chronic disease in their care.
McWilliam, Carol L
2009-12-01
Self-care management is essential for effective chronic disease management. Yet prevailing approaches of healthcare practitioners often undermine the efforts of those who require on-going medical attention for chronic conditions, emphasizing their status as patients, failing to consider their larger life experience as people, and most importantly, failing to consider them as people with the potential to be partners in their care. This article explores two approaches for professional-patient interaction in chronic disease management, namely, patient-centred care and empowering partnering, illuminating how professionals might better interact with chronically ill individuals who seek their care. The opportunities, challenges, theory and research evidence associated with each approach are explored. The advantages of moving beyond patient-centred care to the empowering partnering approach are elaborated. For people with chronic disease, having the opportunity to engage in the social construction of their own health as a resource for everyday living, the opportunity to experience interdependence rather than dependence/independence throughout on-going healthcare, and the opportunity to optimize their potential for self-care management of chronic disease are important justifications for being involved in an empowering partnering approach to their chronic disease management.
Visible-light optical coherence tomography: a review
NASA Astrophysics Data System (ADS)
Shu, Xiao; Beckmann, Lisa; Zhang, Hao F.
2017-12-01
Visible-light optical coherence tomography (vis-OCT) is an emerging imaging modality, providing new capabilities in both anatomical and functional imaging of biological tissue. It relies on visible light illumination, whereas most commercial and investigational OCTs use near-infrared light. As a result, vis-OCT requires different considerations in engineering design and implementation but brings unique potential benefits to both fundamental research and clinical care of several diseases. Here, we intend to provide a summary of the development of vis-OCT and its demonstrated applications. We also provide perspectives on future technology improvement and applications.
Sleep and breathing in congestive heart failure.
Rosen, David; Roux, Francoise Joelle; Shah, Neomi
2014-09-01
Heart failure (HF) is one of the most prevalent and costly diseases in the United States. Sleep apnea is now recognized as a common, yet underdiagnosed, comorbidity of HF. This article discusses the unique qualities that sleep apnea has when it occurs in HF and explains the underlying pathophysiology that illuminates why sleep apnea and HF frequently occur together. The authors provide an overview of the treatment options for sleep apnea in HF and discuss the relative efficacies of these treatments. Copyright © 2014 Elsevier Inc. All rights reserved.
[Study on single-walled carbon nanotube thin film photoelectric device].
Xie, Wen-bin; Zhu, Yong; Gong, Tian-cheng; Chen, Yu-lin; Zhang, Jie
2015-01-01
The single-walled carbon nanotube film photoelectric device was invented, and it can generate net photocurrent under bias voltage when it is illuminated by the laser. The influences of bias voltage, laser power and illuminating position on the net photocurrent were investigated. The experimental results showed that when the center of the film was illuminated, the photocurrent increased with the applied bias, but tended to saturate as the laser power increased. As the voltage and the laser power reached 0. 2 V and 22. 7 mW respectively, the photocurrent reached 0. 24 µA. When the voltage was removed, the photocurrent varied with the laser illuminating position on the film and its value was distributed symmetrically about the center of the device. The photocurrent reached maximum and almost zero respectively when the laser illuminated on two ends and the center of the film. Analysis proposes that the net photocurrent can be generated due to internal photoelectric effect when the device is under voltage and the laser illuminates on the center of the film. It can be also generated due to photo-thermoelectric effect when the device is under no voltage and the laser illuminates on the film, and the relation between the net photocurrent and the illuminating position was derived according to the nature of thermoelectric power of single-walled carbon nanotubes with the established temperature model, which coincides with experimental result. Two effects are the reasons for the generation and variety of the net photocurrent and they superimpose to form the result of the net photocurrent when the device is under general conditions of voltage and laser illuminating position. The device has potential applications in the areas of photovoltaic device and optical sensor for its characteristic.
Back-illuminated imager and method for making electrical and optical connections to same
NASA Technical Reports Server (NTRS)
Pain, Bedabrata (Inventor)
2010-01-01
Methods for bringing or exposing metal pads or traces to the backside of a backside-illuminated imager allow the pads or traces to reside on the illumination side for electrical connection. These methods provide a solution to a key packaging problem for backside thinned imagers. The methods also provide alignment marks for integrating color filters and microlenses to the imager pixels residing on the frontside of the wafer, enabling high performance multispectral and high sensitivity imagers, including those with extremely small pixel pitch. In addition, the methods incorporate a passivation layer for protection of devices against external contamination, and allow interface trap density reduction via thermal annealing. Backside-illuminated imagers with illumination side electrical connections are also disclosed.
Role of color memory in successive color constancy.
Ling, Yazhu; Hurlbert, Anya
2008-06-01
We investigate color constancy for real 2D paper samples using a successive matching paradigm in which the observer memorizes a reference surface color under neutral illumination and after a temporal interval selects a matching test surface under the same or different illumination. We find significant effects of the illumination, reference surface, and their interaction on the matching error. We characterize the matching error in the absence of illumination change as the "pure color memory shift" and introduce a new index for successive color constancy that compares this shift against the matching error under changing illumination. The index also incorporates the vector direction of the matching errors in chromaticity space, unlike the traditional constancy index. With this index, we find that color constancy is nearly perfect.
Illumination-redistribution lenses for non-circular spots
NASA Astrophysics Data System (ADS)
Parkyn, William A.; Pelka, David G.
2005-08-01
The design of illumination lenses is far easier under the regime of the small-source approximation, whereby central rays are taken as representative of the entire source. This implies that the lens is much larger than the source's active emitter, and its entire interior surface is nowhere close to the source. Also, a given source luminance requires a minimum lens area to achieve the candlepower necessary for target illumination. We introduce two-surface aspheric lenses for specific illuminations tasks involving ceiling-mounted downlights, lenses that achieve uniform illuminance at the output aperture as well as at the target. This means that squared-off lenses will produce square spots. In particular, a semicircular lens and a vertical mirror will produce a semicircular spot suitable for gambling tables.
Probabilistic BPRRC: Robust Change Detection against Illumination Changes and Background Movements
NASA Astrophysics Data System (ADS)
Yokoi, Kentaro
This paper presents Probabilistic Bi-polar Radial Reach Correlation (PrBPRRC), a change detection method that is robust against illumination changes and background movements. Most of the traditional change detection methods are robust against either illumination changes or background movements; BPRRC is one of the illumination-robust change detection methods. We introduce a probabilistic background texture model into BPRRC and add the robustness against background movements including foreground invasions such as moving cars, walking people, swaying trees, and falling snow. We show the superiority of PrBPRRC in the environment with illumination changes and background movements by using three public datasets and one private dataset: ATON Highway data, Karlsruhe traffic sequence data, PETS 2007 data, and Walking-in-a-room data.
Modelling of a laser-pumped light source for endoscopic surgery
NASA Astrophysics Data System (ADS)
Nadeau, Valerie J.; Elson, Daniel S.; Hanna, George B.; Neil, Mark A. A.
2008-09-01
A white light source, based on illumination of a yellow phosphor with a fibre-coupled blue-violet diode laser, has been designed and built for use in endoscopic surgery. This narrow light probe can be integrated into a standard laparoscope or inserted into the patient separately via a needle. We present a Monte Carlo model of light scattering and phosphorescence within the phosphor/silicone matrix at the probe tip, and measurements of the colour, intensity, and uniformity of the illumination. Images obtained under illumination with this light source are also presented, demonstrating the improvement in illumination quality over existing endoscopic light sources. This new approach to endoscopic lighting has the advantages of compact design, improved ergonomics, and more uniform illumination in comparison with current technologies.
Illumination control apparatus for compensating solar light
NASA Technical Reports Server (NTRS)
Owens, L. J. (Inventor)
1978-01-01
An illumination control apparatus is presented for supplementing light from solar radiation with light from an artificial light source to compensate for periods of insufficient levels of solar light. The apparatus maintains a desired illumination level within an interior space comprising an artificial light source connected to an electrical power source with a switch means for selectively energizing said light source. An actuator means for controlling the on-off operation of the switch means is connected to a light sensor which responses to the illumination level of the interior space. A limit switch carried adjacent to the actuator limits the movement of the actuator within a predetermined range so as to prevent further movement thereof during detection of erroneous illumination conditions.
Multibeam interferometric illumination as the primary source of resolution in optical microscopy
NASA Astrophysics Data System (ADS)
Ryu, J.; Hong, S. S.; Horn, B. K. P.; Freeman, D. M.; Mermelstein, M. S.
2006-04-01
High-resolution images of a fluorescent target were obtained using a low-resolution optical detector by illuminating the target with interference patterns produced with 31 coherent beams. The beams were arranged in a cone with 78° half angle to produce illumination patterns consistent with a numerical aperture of 0.98. High-resolution images were constructed from low-resolution images taken with 930 different illumination patterns. Results for optical detectors with numerical apertures of 0.1 and 0.2 were similar, demonstrating that the resolution is primarily determined by the illuminator and not by the low-resolution detector. Furthermore, the long working distance, large depth of field, and large field of view of the low-resolution detector are preserved.
Enhancing multi-spot structured illumination microscopy with fluorescence difference
NASA Astrophysics Data System (ADS)
Ward, Edward N.; Torkelsen, Frida H.; Pal, Robert
2018-03-01
Structured illumination microscopy is a super-resolution technique used extensively in biological research. However, this technique is limited in the maximum possible resolution increase. Here we report the results of simulations of a novel enhanced multi-spot structured illumination technique. This method combines the super-resolution technique of difference microscopy with structured illumination deconvolution. Initial results give at minimum a 1.4-fold increase in resolution over conventional structured illumination in a low-noise environment. This new technique also has the potential to be expanded to further enhance axial resolution with three-dimensional difference microscopy. The requirement for precise pattern determination in this technique also led to the development of a new pattern estimation algorithm which proved more efficient and reliable than other methods tested.
Detection of Single Molecules Illuminated by a Light-Emitting Diode
Gerhardt, Ilja; Mai, Lijian; Lamas-Linares, Antía; Kurtsiefer, Christian
2011-01-01
Optical detection and spectroscopy of single molecules has become an indispensable tool in biological imaging and sensing. Its success is based on fluorescence of organic dye molecules under carefully engineered laser illumination. In this paper we demonstrate optical detection of single molecules on a wide-field microscope with an illumination based on a commercially available, green light-emitting diode. The results are directly compared with laser illumination in the same experimental configuration. The setup and the limiting factors, such as light transfer to the sample, spectral filtering and the resulting signal-to-noise ratio are discussed. A theoretical and an experimental approach to estimate these parameters are presented. The results can be adapted to other single emitter and illumination schemes. PMID:22346610
NASA Astrophysics Data System (ADS)
Li, Jun; Fu, Yi-Zhou; Huang, Chuan-Xin; Zhang, Jian-Hua; Jiang, Xue-Yin; Zhang, Zhi-Lin
2016-04-01
This work presents a strategy of nitrogen anion doping to suppress negative gate-bias illumination instability. The electrical performance and negative gate-bias illumination stability of the ZnSnON thin film transistors (TFTs) are investigated. Compared with ZnSnO-TFT, ZnSnON-TFT has a 53% decrease in the threshold voltage shift under negative bias illumination stress and electrical performance also progresses obviously. The stability improvement of ZnSnON-TFT is attributed to the reduction in ionized oxygen vacancy defects and the photodesorption of oxygen-related molecules. It suggests that anion doping can provide an effective solution to the adverse tradeoff between field effect mobility and negative bias illumination stability.
Midwestern Medieval Illuminations Archives.
ERIC Educational Resources Information Center
Purdue Univ., Lafayette, IN. Audio-Visual Center.
This catalog lists the slides of medieval manuscript illuminations available at the Midwestern Medieval Illuminations Archives at the Purdue University Audio-Visual Center. Instructions are provided for ordering slides from the Center. Slide sets are listed by title, with citations including catalog number, rental price, producer/vendor code,…
Identification and Comprehension of Symbolic Exit Signs for Small Transport-Category Airplanes
2014-02-01
8 Phase Two: Self -illuminated Exit Signs...11 Self -illuminated Exit Sign Comprehension ---------------------------------------------------------------------- 12 Automatic...other sign parameters such as stroke width to height, contrast ratios, and self -illumination, fall within those recommended by 14 CFR 25.812(b)(2
USDA-ARS?s Scientific Manuscript database
Structured illumination using sinusoidal patterns has been utilized for optical imaging of biological tissues in biomedical research and, of horticultural products. Implementation of structured-illumination imaging relies on retrieval of amplitude images, which is conventionally achieved by a phase-...
32 CFR 707.10 - Wake illumination light.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 32 National Defense 5 2010-07-01 2010-07-01 false Wake illumination light. 707.10 Section 707.10 National Defense Department of Defense (Continued) DEPARTMENT OF THE NAVY NAVIGATION SPECIAL RULES WITH... display a white spot light located near the stern to illuminate the wake. ...
Investigation of interface property in Al/SiO2/ n-SiC structure with thin gate oxide by illumination
NASA Astrophysics Data System (ADS)
Chang, P. K.; Hwu, J. G.
2017-04-01
The reverse tunneling current of Al/SiO2/ n-SiC structure employing thin gate oxide is introduced to examine the interface property by illumination. The gate current at negative bias decreases under blue LED illumination, yet increases under UV lamp illumination. Light-induced electrons captured by interface states may be emitted after the light sources are off, leading to the recovery of gate currents. Based on transient characteristics of gate current, the extracted trap level is close to the light energy for blue LED, indicating that electron capture induced by lighting may result in the reduction of gate current. Furthermore, bidirectional C- V measurements exhibit a positive voltage shift caused by electron trapping under blue LED illumination, while a negative voltage shift is observed under UV lamp illumination. Distinct trapping and detrapping behaviors can be observed from variations in I- V and C- V curves utilizing different light sources for 4H-SiC MOS capacitors with thin insulators.
Wang, Benquan; Toslak, Devrim; Alam, Minhaj Nur; Chan, R V Paul; Yao, Xincheng
2018-06-08
In conventional fundus photography, trans-pupillary illumination delivers illuminating light to the interior of the eye through the peripheral area of the pupil, and only the central part of the pupil can be used for collecting imaging light. Therefore, the field of view of conventional fundus cameras is limited, and pupil dilation is required for evaluating the retinal periphery which is frequently affected by diabetic retinopathy (DR), retinopathy of prematurity (ROP), and other chorioretinal conditions. We report here a nonmydriatic wide field fundus camera employing trans-pars-planar illumination which delivers illuminating light through the pars plana, an area outside of the pupil. Trans-pars-planar illumination frees the entire pupil for imaging purpose only, and thus wide field fundus photography can be readily achieved with less pupil dilation. For proof-of-concept testing, using all off-the-shelf components a prototype instrument that can achieve 90° fundus view coverage in single-shot fundus images, without the need of pharmacologic pupil dilation was demonstrated.
Chandelier Illumination for Descemet Membrane Endothelial Keratoplasty
Hayashi, Takahiko; Yuda, Kentaro; Tsuchiya, Ayako; Oyakawa, Itaru; Mizuki, Nobuhisa; Kato, Naoko
2017-01-01
Purpose: To describe a simple technique that uses posterior chandelier illumination during Descemet membrane endothelial keratoplasty in cases of severe bullous keratopathy (BK). Methods: Five eyes of 4 patients with advanced BK undergoing Descemet membrane endothelial keratoplasty were retrospectively analyzed. The pupil of the host eye was not treated with mydriatic or miotic agents. The chandelier illuminator was inserted transconjunctivally into the vitreous cavity from the pars plana. Results: In all eyes, BK was secondary to laser iridotomy, which was performed for prevention or treatment of angle closure glaucoma. The implanted graft was clearly confirmed in the anterior chamber using activated chandelier illumination. The graft was immediately attached to the host cornea, with eventual healing of BK in all eyes. No complication involving insertion or removal of the 25-gauge trocar and the chandelier illuminator was observed. No vision-threatening complication was observed in any of the 5 eyes. Conclusions: The chandelier illuminator provided good visibility of the anterior chamber and enhanced the safety of surgery by preventing formation of an inverted graft. PMID:28644235
New reversing design method for LED uniform illumination.
Wang, Kai; Wu, Dan; Qin, Zong; Chen, Fei; Luo, Xiaobing; Liu, Sheng
2011-07-04
In light-emitting diode (LED) applications, it is becoming a big issue that how to optimize light intensity distribution curve (LIDC) and design corresponding optical component to achieve uniform illumination when distance-height ratio (DHR) is given. A new reversing design method is proposed to solve this problem, including design and optimization of LIDC to achieve high uniform illumination and a new algorithm of freeform lens to generate the required LIDC by LED light source. According to this method, two new LED modules integrated with freeform lenses are successfully designed for slim direct-lit LED backlighting with thickness of 10mm, and uniformities of illuminance increase from 0.446 to 0.915 and from 0.155 to 0.887 when DHRs are 2 and 3 respectively. Moreover, the number of new LED modules dramatically decreases to 1/9 of the traditional LED modules while achieving similar uniform illumination in backlighting. Therefore, this new method provides a practical and simple way for optical design of LED uniform illumination when DHR is much larger than 1.
Direct design of achromatic lens for Lambertian sources in collimating illumination
NASA Astrophysics Data System (ADS)
Yin, Peng; Xu, Xiping; Jiang, Zhaoguo; Wang, Hongshu
2017-10-01
Illumination design used to redistribute the spatial energy distribution of light source is a key technique in lighting applications. However, there is still no effective illumination design method for the removing of the chromatic dispersion. What we present here is an achromatic lens design to enhance the efficiency and uniform illumination of white light-emitting diode (LED) with diffractive optical element (DOE). We employ the chromatic aberration value (deg) to measure the degree of chromatic dispersion in illumination systems. Monte Carlo ray tracing simulation results indicate that the chromatic dispersion of the modified achromatic collimator significantly decreases from 0.5 to 0.1 with LED chip size of 1.0mm×1.0mm and simulation efficiency of 90.73%, compared with the traditional collimator. Moreover, with different corrected wavelengths we compared different chromatic aberration values that followed with the changing pupil percent. The achromatic collimator provided an effective way to achieve white LED with low chromatic dispersion at high efficiency and uniform illumination.
Jung, Hyunjun; Kang, Hongki; Nam, Yoonkey
2017-06-01
Light-mediated neuromodulation techniques provide great advantages to investigate neuroscience due to its high spatial and temporal resolution. To generate a spatial pattern of neural activity, it is necessary to develop a system for patterned-light illumination to a specific area. Digital micromirror device (DMD) based patterned illumination system have been used for neuromodulation due to its simple configuration and design flexibility. In this paper, we developed a patterned near-infrared (NIR) illumination system for region specific photothermal manipulation of neural activity using NIR-sensitive plasmonic gold nanorods (GNRs). The proposed system had high power transmission efficiency for delivering power density up to 19 W/mm 2 . We used a GNR-coated microelectrode array (MEA) to perform biological experiments using E18 rat hippocampal neurons and showed that it was possible to inhibit neural spiking activity of specific area in neural circuits with the patterned NIR illumination. This patterned NIR illumination system can serve as a promising neuromodulation tool to investigate neuroscience in a wide range of physiological and clinical applications.
Memory color assisted illuminant estimation through pixel clustering
NASA Astrophysics Data System (ADS)
Zhang, Heng; Quan, Shuxue
2010-01-01
The under constrained nature of illuminant estimation determines that in order to resolve the problem, certain assumptions are needed, such as the gray world theory. Including more constraints in this process may help explore the useful information in an image and improve the accuracy of the estimated illuminant, providing that the constraints hold. Based on the observation that most personal images have contents of one or more of the following categories: neutral objects, human beings, sky, and plants, we propose a method for illuminant estimation through the clustering of pixels of gray and three dominant memory colors: skin tone, sky blue, and foliage green. Analysis shows that samples of the above colors cluster around small areas under different illuminants and their characteristics can be used to effectively detect pixels falling into each of the categories. The algorithm requires the knowledge of the spectral sensitivity response of the camera, and a spectral database consisted of the CIE standard illuminants and reflectance or radiance database of samples of the above colors.
Optical detection dental disease using polarized light
Everett, Matthew J.; Colston, Jr., Billy W.; Sathyam, Ujwal S.; Da Silva, Luiz B.; Fried, Daniel
2003-01-01
A polarization sensitive optical imaging system is used to detect changes in polarization in dental tissues to aid the diagnosis of dental disease such as caries. The degree of depolarization is measured by illuminating the dental tissue with polarized light and measuring the polarization state of the backscattered light. The polarization state of this reflected light is analyzed using optical polarimetric imaging techniques. A hand-held fiber optic dental probe is used in vivo to direct the incident beam to the dental tissue and collect the reflected light. To provide depth-resolved characterization of the dental tissue, the polarization diagnostics may be incorporated into optical coherence domain reflectometry and optical coherence tomography (OCDR/OCT) systems, which enables identification of subsurface depolarization sites associated with demineralization of enamel or bone.
Breast cancer early detection via tracking of skin back-scattered secondary speckle patterns
NASA Astrophysics Data System (ADS)
Bennett, Aviya; Sirkis, Talia; Beiderman, Yevgeny; Agdarov, Sergey; Beiderman, Yafim; Zalevsky, Zeev
2018-02-01
Breast cancer has become a major cause of death among women. The lifetime risk of a woman developing this disease has been established as one in eight. The most useful way to reduce breast cancer death is to treat the disease as early as possible. The existing methods of early diagnostics of breast cancer are mainly based on screening mammography or Magnetic Resonance Imaging (MRI) periodically conducted at medical facilities. In this paper the authors proposing a new approach for simple breast cancer detection. It is based on skin stimulation by sound waves, illuminating it by laser beam and tracking the reflected secondary speckle patterns. As first approach, plastic balls of different sizes were placed under the skin of chicken breast and detected by the proposed method.
Sampling populations of humans across the world: ELSI issues.
Knoppers, Bartha Maria; Zawati, Ma'n H; Kirby, Emily S
2012-01-01
There are an increasing number of population studies collecting data and samples to illuminate gene-environment contributions to disease risk and health. The rising affordability of innovative technologies capable of generating large amounts of data helps achieve statistical power and has paved the way for new international research collaborations. Most data and sample collections can be grouped into longitudinal, disease-specific, or residual tissue biobanks, with accompanying ethical, legal, and social issues (ELSI). Issues pertaining to consent, confidentiality, and oversight cannot be examined using a one-size-fits-all approach-the particularities of each biobank must be taken into account. It remains to be seen whether current governance approaches will be adequate to handle the impact of next-generation sequencing technologies on communication with participants in population biobanking studies.
Construction and validation of a Tamil logMAR chart.
Varadharajan, Srinivasa; Srinivasan, Krithica; Kumaresan, Brindha
2009-09-01
To design, construct and validate a new Tamil logMAR visual acuity chart based on current recommendations. Ten Tamil letters of equal legibility were identified experimentally and were used in the chart. Two charts, one internally illuminated and one externally illuminated, were constructed for testing at 4 m distance. The repeatability of the two charts was tested. For validation, the two charts were compared with a standard English logMAR chart (ETDRS). When compared to the ETDRS chart, a difference of 0.06 +/- 0.07 and 0.07 +/- 0.07 logMAR was found for the internally and externally illuminated charts respectively. Limits of agreement between the internally illuminated Tamil logMAR chart and ETDRS chart were found to be (-0.08, 0.19), and (-0.07, 0.20) for the externally illuminated chart. The test - retest results showed a difference of 0.02 +/- 0.04 and 0.02 +/- 0.06 logMAR for the internally and externally illuminated charts respectively. Limits of agreement for repeated measurements for the internally illuminated Tamil logMAR chart were found to be (-0.06, 0.10), and (-0.10, 0.14) for the externally illuminated chart. The newly constructed Tamil logMAR charts have good repeatability. The difference in visual acuity scores between the newly constructed Tamil logMAR chart and the standard English logMAR chart was within acceptable limits. This new chart can be used for measuring visual acuity in the literate Tamil population.
Cionni, Robert J; Pei, Ron; Dimalanta, Ramon; Lubeck, David
2015-08-01
To evaluate the intensity and stability of the red reflex produced by ophthalmic surgical microscopes with nearly-collimated versus focused illumination systems and to assess surgeon preference in a simulated surgical setting. This two-part evaluation consisted of postproduction surgical video analysis of red reflex intensity and a microscope use and preference survey completed by 13 experienced cataract surgeons. Survey responses were based on bench testing and experience in a simulated surgical setting. A microscope with nearly-collimated beam illumination and two focused beam microscopes were assessed. Red reflex intensity and stability were greater with the nearly-collimated microscope illumination system. In the bench testing survey, surgeons reported that the red reflex was maintained over significantly greater distances away from pupillary center, and depth of focus was numerically greater with nearly-collimated illumination relative to focused illumination. Most participating surgeons (≥64%) reported a preference for the microscope with nearly-collimated illumination with regard to red reflex stability, depth of focus, visualization, surgical working distance, and perceived patient comfort. The microscope with nearly-collimated illumination produced a more intense and significantly more stable red reflex and was preferred overall by more surgeons. This is the first report of an attempt to quantify red reflex intensity and stability and to evaluate surgically-relevant parameters between microscope systems. The data and methods presented here may provide a basis for future studies attempting to quantify differences between surgical microscopes that may affect surgeon preference and microscope use in ophthalmic surgery.
Kumar, Amit; Ghate, Vinayak; Kim, Min-Jeong; Zhou, Weibiao; Khoo, Gek Hoon; Yuk, Hyun-Gyun
2017-05-01
The objective of this study was to investigate the effect of 460 nm light-emitting diode (LED) on the inactivation of foodborne bacteria. Additionally, the change in the endogenous metabolic profile of LED illuminated cells was analyzed to understand the bacterial response to the LED illumination. Six different species of bacteria (Bacillus cereus, Listeria monocytogenes, Staphylococcus aureus, Escherichia coli O157:H7, Pseudomonas aeruginosa and Salmonella Typhimurium) were illuminated with 460 nm LED to a maximum dose of 4080 J/cm 2 at 4, 10 and 25 °C. Inactivation curves were modeled using Hom model. Metabolic profiling of the non-illuminated and illuminated cells was performed using a Liquid chromatography-mass spectrometry system. Results indicate that the 460 nm LED significantly (p < 0.05) reduced the populations of all six bacterial species. For example, the population of S. aureus reached below detection limit within 7 h. B. cereus was most resistant to photo-inactivation and exhibited about 3-log reduction in 9 h. Metabolic profiling of the illuminated cells indicated that several metabolites e.g. 11-deoxycortisol, actinonin, coformycin, tyramine, chitobiose etc. were regulated during LED illumination. These results elucidate the effectiveness of 460 nm LED against foodborne bacteria and hence, its suitability as a novel antimicrobial control method to ensure food safety. Copyright © 2016 Elsevier Ltd. All rights reserved.
Context-aware tunable office lighting application and user response
NASA Astrophysics Data System (ADS)
Chen, Nancy H.; Nawyn, Jason; Thompson, Maria; Gibbs, Julie; Larson, Kent
2013-09-01
LED light sources having multiple independently controllable color channels allow tuning of both the intensity and color output. Consequently, highly tailored lighting can be applied according to instantaneous user needs and preferences. Besides improving lighting performance, energy use can also be reduced since the brightest illumination is applied only when necessary. In an example application, low activity or vacant areas of a multi-zone office are lit by low power illumination, including colored light options, which can reduce energy consumption to 20-45% of typical full-time, fullbrightness, office-wide illumination. The availability of color also allows communication functions and additional aesthetic design possibilities. To reduce user burden in frequent switching between various illumination settings, an activity recognition sensor network is used to identify selected office activities. The illumination is then adjusted automatically to satisfy the needs of the occupants. A handheld mobile device provides an interactive interface for gathering user feedback regarding impressions and illumination preferences. The activity-triggered queries collect contemporaneous feedback that reduces reliance on memory; immediate previews of illumination options are also provided. Through mobile queries and post-experience interviews, user feedback was gathered regarding automation, colored lighting, and illumination preferences. Overall reaction was indicated by a range of response words such as fun, stimulating, very cool, very pleasant, enjoyed, good, comfortable, satisfactory, fine, energy saving, interesting, curious, dim, cave, isolated, distracting, and unfamiliar. Positive reaction from a meaningful, though not universal, fraction of users indicates reasonable application potential, particularly as personal preferences and control are accommodated.
Pouzoulet, Jérôme; Pivovaroff, Alexandria L.; Santiago, Louis S.; Rolshausen, Philippe E.
2014-01-01
This review illuminates key findings in our understanding of grapevine xylem resistance to fungal vascular wilt diseases. Grapevine (Vitis spp.) vascular diseases such as esca, botryosphaeria dieback, and eutypa dieback, are caused by a set of taxonomically unrelated ascomycete fungi. Fungal colonization of the vascular system leads to a decline of the plant host because of a loss of the xylem function and subsequent decrease in hydraulic conductivity. Fungal vascular pathogens use different colonization strategies to invade and kill their host. Vitis vinifera cultivars display different levels of tolerance toward vascular diseases caused by fungi, but the plant defense mechanisms underlying those observations have not been completely elucidated. In this review, we establish a parallel between two vascular diseases, grapevine esca disease and Dutch elm disease, and argue that the former should be viewed as a vascular wilt disease. Plant genotypes exhibit differences in xylem morphology and resistance to fungal pathogens causing vascular wilt diseases. We provide evidence that the susceptibility of three commercial V. vinifera cultivars to esca disease is correlated to large vessel diameter. Additionally, we explore how xylem morphological traits related to water transport are influenced by abiotic factors, and how these might impact host tolerance of vascular wilt fungi. Finally, we explore the utility of this concept for predicting which V. vinifera cultivars are most vulnerable of fungal vascular wilt diseases and propose new strategies for disease management. PMID:24971084
Whole exome resequencing distinguishes cystic kidney diseases from phenocopies in renal ciliopathies
Gee, Heon Yung; Otto, Edgar A.; Hurd, Toby W.; Ashraf, Shazia; Chaki, Moumita; Cluckey, Andrew; Vega-Warner, Virginia; Saisawat, Pawaree; Diaz, Katrina A.; Fang, Humphrey; Kohl, Stefan; Allen, Susan J.; Airik, Rannar; Zhou, Weibin; Ramaswami, Gokul; Janssen, Sabine; Fu, Clementine; Innis, Jamie L.; Weber, Stefanie; Vester, Udo; Davis, Erica E.; Katsanis, Nicholas; Fathy, Hanan M.; Jeck, Nikola; Klaus, Gunther; Nayir, Ahmet; Rahim, Khawla A.; Attrach, Ibrahim Al; Hassoun, Ibrahim Al; Ozturk, Savas; Drozdz, Dorota; Helmchen, Udo; O’Toole, John F.; Attanasio, Massimo; Nürnberg, Gudrun; Nürnberg, Peter; Washburn, Joseph; MacDonald, James; James, Jeffrey W.; Levy, Shawn; Hildebrandt, Friedhelm
2013-01-01
Rare single-gene disorders cause chronic disease. However, half of the 6,000 recessive single gene causes of disease are still unknown. Because recessive disease genes can illuminate, at least in part, disease pathomechanism, their identification offers direct opportunities for improved clinical management and potentially treatment. Rare diseases comprise the majority of chronic kidney disease (CKD) in children but are notoriously difficult to diagnose. Whole exome resequencing facilitates identification of recessive disease genes. However, its utility is impeded by the large number of genetic variants detected. We here overcome this limitation by combining homozygosity mapping with whole exome resequencing in 10 sib pairs with a nephronophthisis-related ciliopathy, which represents the most frequent genetic cause of CKD in the first three decades of life. In 7 of 10 sib-ships with a histologic or ultrasonographic diagnosis of nephronophthisis-related ciliopathy we detect the causative gene. In six sib-ships we identify mutations of known nephronophthisis-related ciliopathy genes, while in two additional sib-ships we found mutations in the known CKD-causing genes SLC4A1 and AGXT as phenocopies of nephronophthisis-related ciliopathy. Thus whole exome resequencing establishes an efficient, non-invasive approach towards early detection and causation-based diagnosis of rare kidney diseases. This approach can be extended to other rare recessive disorders, thereby providing accurate diagnosis and facilitating the study of disease mechanisms. PMID:24257694
Gee, Heon Yung; Otto, Edgar A; Hurd, Toby W; Ashraf, Shazia; Chaki, Moumita; Cluckey, Andrew; Vega-Warner, Virginia; Saisawat, Pawaree; Diaz, Katrina A; Fang, Humphrey; Kohl, Stefan; Allen, Susan J; Airik, Rannar; Zhou, Weibin; Ramaswami, Gokul; Janssen, Sabine; Fu, Clementine; Innis, Jamie L; Weber, Stefanie; Vester, Udo; Davis, Erica E; Katsanis, Nicholas; Fathy, Hanan M; Jeck, Nikola; Klaus, Gunther; Nayir, Ahmet; Rahim, Khawla A; Al Attrach, Ibrahim; Al Hassoun, Ibrahim; Ozturk, Savas; Drozdz, Dorota; Helmchen, Udo; O'Toole, John F; Attanasio, Massimo; Lewis, Richard A; Nürnberg, Gudrun; Nürnberg, Peter; Washburn, Joseph; MacDonald, James; Innis, Jeffrey W; Levy, Shawn; Hildebrandt, Friedhelm
2014-04-01
Rare single-gene disorders cause chronic disease. However, half of the 6000 recessive single gene causes of disease are still unknown. Because recessive disease genes can illuminate, at least in part, disease pathomechanism, their identification offers direct opportunities for improved clinical management and potentially treatment. Rare diseases comprise the majority of chronic kidney disease (CKD) in children but are notoriously difficult to diagnose. Whole-exome resequencing facilitates identification of recessive disease genes. However, its utility is impeded by the large number of genetic variants detected. We here overcome this limitation by combining homozygosity mapping with whole-exome resequencing in 10 sib pairs with a nephronophthisis-related ciliopathy, which represents the most frequent genetic cause of CKD in the first three decades of life. In 7 of 10 sibships with a histologic or ultrasonographic diagnosis of nephronophthisis-related ciliopathy, we detect the causative gene. In six sibships, we identify mutations of known nephronophthisis-related ciliopathy genes, while in two additional sibships we found mutations in the known CKD-causing genes SLC4A1 and AGXT as phenocopies of nephronophthisis-related ciliopathy. Thus, whole-exome resequencing establishes an efficient, noninvasive approach towards early detection and causation-based diagnosis of rare kidney diseases. This approach can be extended to other rare recessive disorders, thereby providing accurate diagnosis and facilitating the study of disease mechanisms.
Structured-illumination reflectance imaging as a new modality for food quality detection
USDA-ARS?s Scientific Manuscript database
Uniform or diffuse illumination is the standard in implementing many different imaging modalities. This form of illumination, however, has some major limitations in acquisition of useful information from food products because reflectance from the food products is non-uniform due to irregular, curved...
DOT National Transportation Integrated Search
2016-03-01
This report is for the first phase of a two-phase research program to develop recommended practices for GDOT for lighting rural roundabouts. Phase I of the study was designed to improve our understanding of the relationship between roundabout illumin...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-26
... Laser Illumination of Aircraft AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice and... collection covers the reporting of unauthorized illumination of aircraft by lasers. DATES: Written comments.... Title: Reporting of Laser Illumination of Aircraft. Form Numbers: Advisory Circular 70-2. Type of Review...
Back-illuminated CCD imager adapted for contrast transfer function measurements thereon
NASA Technical Reports Server (NTRS)
Levine, Peter A. (Inventor)
1987-01-01
Stripe patterns of varying spatial frequency, formed in the top-metalization of a back-illuminated solid-state imager, facilitate on-line measurement of contrast transfer function during wafer-probe testing. The imager may be packaged to allow front-illumination during in-the-field testing after its manufacture.
USDA-ARS?s Scientific Manuscript database
Structured-illumination reflectance imaging (SIRI) provides a new means for enhanced detection of defects in horticultural products. Implementing the technique relies on retrieving amplitude images by illuminating the object with sinusoidal patterns of single spatial frequencies, which, however, are...
30 CFR 56.17001 - Illumination of surface working areas.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Illumination of surface working areas. 56.17001 Section 56.17001 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Illumination...
10 CFR 431.202 - Definitions concerning illuminated exit signs.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Section 431.202 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN... efficiency, water consumption, or water efficiency. Face means an illuminated side of an illuminated exit... batteries, input power demand shall be measured with batteries at full charge. [70 FR 60417, Oct. 18, 2005...
10 CFR 431.202 - Definitions concerning illuminated exit signs.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Section 431.202 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN... efficiency, water consumption, or water efficiency. Face means an illuminated side of an illuminated exit... batteries, input power demand shall be measured with batteries at full charge. [70 FR 60417, Oct. 18, 2005...
10 CFR 431.202 - Definitions concerning illuminated exit signs.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Section 431.202 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN... efficiency, water consumption, or water efficiency. Face means an illuminated side of an illuminated exit... batteries, input power demand shall be measured with batteries at full charge. [70 FR 60417, Oct. 18, 2005...
Adaptive Ambient Illumination Based on Color Harmony Model
NASA Astrophysics Data System (ADS)
Kikuchi, Ayano; Hirai, Keita; Nakaguchi, Toshiya; Tsumura, Norimichi; Miyake, Yoichi
We investigated the relationship between ambient illumination and psychological effect by applying a modified color harmony model. We verified the proposed model by analyzing correlation between psychological value and modified color harmony score. Experimental results showed the possibility to obtain the best color for illumination using this model.
USDA-ARS?s Scientific Manuscript database
In this research, a novel method of fresh bruise detection was developed using a structured illumination reflectance imaging (SIRI) system. The SIRI system projects sinusoidal patterns of illumination onto samples, and image demodulation is then used to recover depth-specific information through var...
Sabatini, Jesse J; Raab, James M; Hann, Ronald K; Damavarapu, Reddy; Klapötke, Thomas M
2012-06-01
The development of perchlorate-free hand-held signal illuminants for the US Army's M195 green star parachute is described. Compared with the perchlorate-containing control, the optimized perchlorate-free illuminants were less sensitive toward various ignition stimuli while offering comparable burn times and visible-light outputs. The results were also important from the perspective of civilian fireworks because the development of perchlorate-free illuminants remains an important objective of the commercial fireworks industry. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
[Light modes and ovulation function in rats in ontogenesis].
Vinogradova, I A; Chernova, I V
2007-01-01
Enhancement of illumination was shown to lead to occurrence of early and more obvious age-dependent changes of ovulation cycle in rats as compared with the same changes in animals staying in conditions of light deprivation or standard illumination. The effect of 24-hour illumination during a year induced more obvious and still earlier changes of the estrus cycle that the effect of natural illumination in the North-West of Russia with its peculiar yearly photo-periodicity (short light day in the autumn-winter period and "white nights" in the spring-summer period).
Optical design applications for enhanced illumination performance
NASA Astrophysics Data System (ADS)
Gilray, Carl; Lewin, Ian
1995-08-01
Nonimaging optical design techniques have been applied in the illumination industry for many years. Recently however, powerful software has been developed which allows accurate simulation and optimization of illumination devices. Wide experience has been obtained in using such design techniques for practical situations. These include automotive lighting where safety is of greatest importance, commercial lighting systems designed for energy efficiency, and numerous specialized applications. This presentation will discuss the performance requirements of a variety of illumination devices. It will further cover design methodology and present a variety of examples of practical applications for enhanced system performance.
Study of chromatic adaptation via neutral white matches on different viewing media.
Zhai, Qiyan; Luo, Ming R
2018-03-19
Two experiments were carried out to study the neutral white and the chromatic adaptation in human vision and color science. After matching neutral whites under different illuminants using both surface and self-luminous colors, the result were used to verify the previous study about the chromatic adaptation. Not all the white illuminants were found neutral even the adaptation time is long. The baseline illuminant of the two-step chromatic adaptation transform was found as the illuminant with the same chromaticity of the neutral white under it and depended on viewing medium in the present study. The results were also used as corresponding colors to derive models of the effective degree of chromatic adaptation, which were found highly associated with the chromaticity of the adapting illuminant.
An inexpensive programmable illumination microscope with active feedback.
Tompkins, Nathan; Fraden, Seth
2016-02-01
We have developed a programmable illumination system capable of tracking and illuminating numerous objects simultaneously using only low-cost and reused optical components. The active feedback control software allows for a closed-loop system that tracks and perturbs objects of interest automatically. Our system uses a static stage where the objects of interest are tracked computationally as they move across the field of view allowing for a large number of simultaneous experiments. An algorithmically determined illumination pattern can be applied anywhere in the field of view with simultaneous imaging and perturbation using different colors of light to enable spatially and temporally structured illumination. Our system consists of a consumer projector, camera, 35-mm camera lens, and a small number of other optical and scaffolding components. The entire apparatus can be assembled for under $4,000.
[Effects of illumination and seed-soaking reagent on seed germination of Solanum nigrum].
Yang, Chuan-Jie; Wei, Shu-He; Zhou, Qi-Xing; Hu, Ya-Hu; Niu, Rong-Cheng
2009-05-01
To explore a rapid seed germination method for hyperaccumulator Solanum nigrum, a germination experiment with different illumination and seed-soaking treatments was conducted in constant temperature box and greenhouse, with filter as burgeon base. Under illumination, the germination rate was about 5 times high of that without illumination (P < 0.05), indicating that illumination was one of the prerequisites for the seed germination of S. nigrum. All test seed-soaking reagents could significantly improve the germination rate of S. nigrum (P < 0.05), with the best effect of H2O2. The seeds treated with H2O2 had the shortest germination time. The germination rate of seeds soaked but without cleaning was 2-3 times as high as that of seeds soaked and cleaned with water.
Rectangular illumination using a secondary optics with cylindrical lens for LED street light.
Chen, Hsi-Chao; Lin, Jun-Yu; Chiu, Hsuan-Yi
2013-02-11
The illumination pattern of an LED street light is required to have a rectangular distribution at a divergence-angle ratio of 7:3 for economical illumination. Hence, research supplying a secondary optics with two cylindrical lenses was different from free-form curvature for rectangular illumination. The analytical solution for curvatures with different ratio rectangles solved this detail by light tracing and boundary conditions. Similarities between the experiments and the simulation for a single LED and a 9-LED module were analyzed by Normalized Cross Correlation (NCC), and the error rate was studied by the Root Mean Square (RMS). The tolerance of position must be kept under ± 0.2 mm in the x, y and z directions to ensure that the relative illumination is over 99%.
Enhancing multi-spot structured illumination microscopy with fluorescence difference
Torkelsen, Frida H.
2018-01-01
Structured illumination microscopy is a super-resolution technique used extensively in biological research. However, this technique is limited in the maximum possible resolution increase. Here we report the results of simulations of a novel enhanced multi-spot structured illumination technique. This method combines the super-resolution technique of difference microscopy with structured illumination deconvolution. Initial results give at minimum a 1.4-fold increase in resolution over conventional structured illumination in a low-noise environment. This new technique also has the potential to be expanded to further enhance axial resolution with three-dimensional difference microscopy. The requirement for precise pattern determination in this technique also led to the development of a new pattern estimation algorithm which proved more efficient and reliable than other methods tested. PMID:29657751
Bosse, Jens B.; Tanneti, Nikhila S.; Hogue, Ian B.; Enquist, Lynn W.
2015-01-01
Dual-color live cell fluorescence microscopy of fast intracellular trafficking processes, such as axonal transport, requires rapid switching of illumination channels. Typical broad-spectrum sources necessitate the use of mechanical filter switching, which introduces delays between acquisition of different fluorescence channels, impeding the interpretation and quantification of highly dynamic processes. Light Emitting Diodes (LEDs), however, allow modulation of excitation light in microseconds. Here we provide a step-by-step protocol to enable any scientist to build a research-grade LED illuminator for live cell microscopy, even without prior experience with electronics or optics. We quantify and compare components, discuss our design considerations, and demonstrate the performance of our LED illuminator by imaging axonal transport of herpes virus particles with high temporal resolution. PMID:26600461
Detection Technique for Artificially Illuminated Objects in the Outer Solar System and Beyond
Loeb, Abraham
2012-01-01
Abstract Existing and planned optical telescopes and surveys can detect artificially illuminated objects, comparable in total brightness to a major terrestrial city, at the outskirts of the Solar System. Orbital parameters of Kuiper belt objects (KBOs) are routinely measured to exquisite precisions of<10−3. Here, we propose to measure the variation of the observed flux F from such objects as a function of their changing orbital distances D. Sunlight-illuminated objects will show a logarithmic slope α ≡ (d log F/d log D)=−4, whereas artificially illuminated objects should exhibit α=−2. The proposed Large Synoptic Survey Telescope (LSST) and other planned surveys will provide superb data and allow measurement of α for thousands of KBOs. If objects with α=−2 are found, follow-up observations could measure their spectra to determine whether they are illuminated by artificial lighting. The search can be extended beyond the Solar System with future generations of telescopes on the ground and in space that would have the capacity to detect phase modulation due to very strong artificial illumination on the nightside of planets as they orbit their parent stars. Key Words: Astrobiology—SETI—Kuiper belt objects—Artificial illumination. Astrobiology 12, 290–294. PMID:22490065
Rohmer, Kai; Buschel, Wolfgang; Dachselt, Raimund; Grosch, Thorsten
2015-12-01
At present, photorealistic augmentation is not yet possible since the computational power of mobile devices is insufficient. Even streaming solutions from stationary PCs cause a latency that affects user interactions considerably. Therefore, we introduce a differential rendering method that allows for a consistent illumination of the inserted virtual objects on mobile devices, avoiding delays. The computation effort is shared between a stationary PC and the mobile devices to make use of the capacities available on both sides. The method is designed such that only a minimum amount of data has to be transferred asynchronously between the participants. This allows for an interactive illumination of virtual objects with a consistent appearance under both temporally and spatially varying real illumination conditions. To describe the complex near-field illumination in an indoor scenario, HDR video cameras are used to capture the illumination from multiple directions. In this way, sources of illumination can be considered that are not directly visible to the mobile device because of occlusions and the limited field of view. While our method focuses on Lambertian materials, we also provide some initial approaches to approximate non-diffuse virtual objects and thereby allow for a wider field of application at nearly the same cost.
Matsuzaki, Jun; Masumori, Masaya; Tange, Takeshi
2007-05-01
Active phototropic bending of non-elongating and radially growing portion of stems (woody stems) has not been previously documented, whereas negative gravitropic bending is well known. We found phototropic bending in woody stems and searched for the underlying mechanism. We inclined 1-year-old Quercus crispula Blume seedlings and unilaterally illuminated them from a horizontal direction perpendicular to ('normal' illumination) or parallel to ('parallel' illumination) the inclination azimuth. With normal illumination, active phototropic bending and xylem formation could be evaluated separately from the negative gravitropic response and vertical deflection resulting from the weight of the seedlings. One-year-old stems with normal illumination bent significantly, with asymmetrical xylem formation towards the illuminated upper surface and side of the stem, whereas those with parallel illumination showed non-significant lateral bending, with asymmetrical xylem formation only on the upper side. A mechanical model was built on the assumption that a bending moment resulted from the asymmetrical xylem formation during phototropic bending of the woody stems. The model fitted the relationship between the observed spatial distributions of the xylem and the observed lateral bending, and thus supported the hypothesis that phototropic bending of woody stems results from asymmetrical xylem formation, as such occurs during gravitropism.
Lai, Jinxing; Qiu, Junling; Chen, Jianxun; Wang, Yaqiong; Fan, Haobo
2014-01-01
Because of the particularity of the environment in the tunnel, the rational tunnel illumination system should be developed, so as to optimize the tunnel environment. Considering the high cost of traditional tunnel illumination system with high-pressure sodium (HPS) lamps as well as the effect of a single light source on tunnel entrance, the energy-saving illumination system with HPS lamps and LEDs combined illumination in road tunnel, which could make full use of these two kinds of lamps, was proposed. The wireless intelligent control system based on HPS lamps and LEDs combined illumination and microcontrol unit (MCU) Si1000 wireless communication technology was designed. And the remote monitoring, wireless communication, and PWM dimming module of this system were designed emphatically. Intensity detector and vehicle flow detector can be configured in wireless intelligent control system, which gather the information to the master control unit, and then the information is sent to the monitoring center through the Ethernet. The control strategies are got by the monitoring center according to the calculated results, and the control unit wirelessly sends parameters to lamps, which adjust the luminance of each segment of the tunnel and realize the wireless intelligent control of combined illumination in road tunnel. PMID:25587266
Human genomic disease variants: a neutral evolutionary explanation.
Dudley, Joel T; Kim, Yuseob; Liu, Li; Markov, Glenn J; Gerold, Kristyn; Chen, Rong; Butte, Atul J; Kumar, Sudhir
2012-08-01
Many perspectives on the role of evolution in human health include nonempirical assumptions concerning the adaptive evolutionary origins of human diseases. Evolutionary analyses of the increasing wealth of clinical and population genomic data have begun to challenge these presumptions. In order to systematically evaluate such claims, the time has come to build a common framework for an empirical and intellectual unification of evolution and modern medicine. We review the emerging evidence and provide a supporting conceptual framework that establishes the classical neutral theory of molecular evolution (NTME) as the basis for evaluating disease- associated genomic variations in health and medicine. For over a decade, the NTME has already explained the origins and distribution of variants implicated in diseases and has illuminated the power of evolutionary thinking in genomic medicine. We suggest that a majority of disease variants in modern populations will have neutral evolutionary origins (previously neutral), with a relatively smaller fraction exhibiting adaptive evolutionary origins (previously adaptive). This pattern is expected to hold true for common as well as rare disease variants. Ultimately, a neutral evolutionary perspective will provide medicine with an informative and actionable framework that enables objective clinical assessment beyond convenient tendencies to invoke past adaptive events in human history as a root cause of human disease.
Human genomic disease variants: A neutral evolutionary explanation
Dudley, Joel T.; Kim, Yuseob; Liu, Li; Markov, Glenn J.; Gerold, Kristyn; Chen, Rong; Butte, Atul J.; Kumar, Sudhir
2012-01-01
Many perspectives on the role of evolution in human health include nonempirical assumptions concerning the adaptive evolutionary origins of human diseases. Evolutionary analyses of the increasing wealth of clinical and population genomic data have begun to challenge these presumptions. In order to systematically evaluate such claims, the time has come to build a common framework for an empirical and intellectual unification of evolution and modern medicine. We review the emerging evidence and provide a supporting conceptual framework that establishes the classical neutral theory of molecular evolution (NTME) as the basis for evaluating disease- associated genomic variations in health and medicine. For over a decade, the NTME has already explained the origins and distribution of variants implicated in diseases and has illuminated the power of evolutionary thinking in genomic medicine. We suggest that a majority of disease variants in modern populations will have neutral evolutionary origins (previously neutral), with a relatively smaller fraction exhibiting adaptive evolutionary origins (previously adaptive). This pattern is expected to hold true for common as well as rare disease variants. Ultimately, a neutral evolutionary perspective will provide medicine with an informative and actionable framework that enables objective clinical assessment beyond convenient tendencies to invoke past adaptive events in human history as a root cause of human disease. PMID:22665443
Kashuk, Carl S.; Stone, Eric A.; Grice, Elizabeth A.; Portnoy, Matthew E.; Green, Eric D.; Sidow, Arend; Chakravarti, Aravinda; McCallion, Andrew S.
2005-01-01
The ability to discriminate between deleterious and neutral amino acid substitutions in the genes of patients remains a significant challenge in human genetics. The increasing availability of genomic sequence data from multiple vertebrate species allows inclusion of sequence conservation and physicochemical properties of residues to be used for functional prediction. In this study, the RET receptor tyrosine kinase serves as a model disease gene in which a broad spectrum (≥116) of disease-associated mutations has been identified among patients with Hirschsprung disease and multiple endocrine neoplasia type 2. We report the alignment of the human RET protein sequence with the orthologous sequences of 12 non-human vertebrates (eight mammalian, one avian, and three teleost species), their comparative analysis, the evolutionary topology of the RET protein, and predicted tolerance for all published missense mutations. We show that, although evolutionary conservation alone provides significant information to predict the effect of a RET mutation, a model that combines comparative sequence data with analysis of physiochemical properties in a quantitative framework provides far greater accuracy. Although the ability to discern the impact of a mutation is imperfect, our analyses permit substantial discrimination between predicted functional classes of RET mutations and disease severity even for a multigenic disease such as Hirschsprung disease. PMID:15956201
Natural light illumination system.
Whang, Allen Jong-Woei; Chen, Yi-Yung; Yang, Shu-Hua; Pan, Po-Hsuan; Chou, Kao-Hsu; Lee, Yu-Chi; Lee, Zong-Yi; Chen, Chi-An; Chen, Cheng-Nan
2010-12-10
In recent years, green energy has undergone a lot of development and has been the subject of many applications. Many research studies have focused on illumination with sunlight as a means of saving energy and creating healthy lighting. Natural light illumination systems have collecting, transmitting, and lighting elements. Today, most daylight collectors use dynamic concentrators; these include Sun tracking systems. However, this design is too expensive to be cost effective. To create a low-cost collector that can be easily installed on a large building, we have designed a static concentrator, which is prismatic and cascadable, to collect sunlight for indoor illumination. The transmission component uses a large number of optical fibers. Because optical fibers are expensive, this means that most of the cost for the system will be related to transmission. In this paper, we also use a prismatic structure to design an optical coupler for coupling n to 1. With the n-to-1 coupler, the number of optical fibers necessary can be greatly reduced. Although this new natural light illumination system can effectively guide collected sunlight and send it to the basement or to other indoor places for healthy lighting, previously there has been no way to manage the collected sunlight when lighting was not desired. To solve this problem, we have designed an optical switch and a beam splitter to control and separate the transmitted light. When replacing traditional sources, the lighting should have similar characteristics, such as intensity distribution and geometric parameters, to those of traditional artificial sources. We have designed, simulated, and optimized an illumination lightpipe with a dot pattern to redistribute the collected sunlight from the natural light illumination system such that it equals the qualities of a traditional lighting system. We also provide an active lighting module that provides lighting from the natural light illumination system or LED auxiliary sources, depending on circumstances. The system is controlled by a light detector. We used optical simulation tools to design and simulate the efficiency of the active module. Finally, we used the natural light illumination system to provide natural illumination for a traffic tunnel. This system will provide a great number of benefits for the people who use it.
Back-illuminate fiber system research for multi-object fiber spectroscopic telescope
NASA Astrophysics Data System (ADS)
Zhou, Zengxiang; Liu, Zhigang; Hu, Hongzhuan; Wang, Jianping; Zhai, Chao; Chu, Jiaru
2016-07-01
In the telescope observation, the position of fiber will highly influence the spectra efficient input in the fiber to the spectrograph. When the fibers were back illuminated on the spectra end, they would export light on the positioner end, so the CCD cameras could capture the photo of fiber tip position covered the focal plane, calculates the precise position information by light centroid method and feeds back to control system. A set of fiber back illuminated system was developed which combined to the low revolution spectro instruments in LAMOST. It could provide uniform light output to the fibers, meet the requirements for the CCD camera measurement. The paper was introduced the back illuminated system design and different test for the light resource. After optimization, the effect illuminated system could compare with the integrating sphere, meet the conditions of fiber position measurement.Using parallel controlled fiber positioner as the spectroscopic receiver is an efficiency observation system for spectra survey, has been used in LAMOST recently, and will be proposed in CFHT and rebuilt telescope Mayall. In the telescope observation, the position of fiber will highly influence the spectra efficient input in the fiber to the spectrograph. When the fibers were back illuminated on the spectra end, they would export light on the positioner end, so the CCD cameras could capture the photo of fiber tip position covered the focal plane, calculates the precise position information by light centroid method and feeds back to control system. After many years on these research, the back illuminated fiber measurement was the best method to acquire the precision position of fibers. In LAMOST, a set of fiber back illuminated system was developed which combined to the low revolution spectro instruments in LAMOST. It could provide uniform light output to the fibers, meet the requirements for the CCD camera measurement and was controlled by high-level observation system which could shut down during the telescope observation. The paper was introduced the back illuminated system design and different test for the light resource. After optimization, the effect illuminated system could compare the integrating sphere, meet the conditions of fiber position measurement.
Post-illumination Pupil Response in Subjects without Ocular Disease
Kankipati, Laxmikanth; Girkin, Christopher A.; Gamlin, Paul D.
2010-01-01
Purpose. A sustained pupilloconstriction is often observed after the cessation of a bright visual stimulus. This post-illumination pupil response (PIPR) is produced by the intrinsically photosensitive retinal ganglion cells (ipRGCs). The present study was designed to examine the characteristics of the PIPR in a normal population without ocular disease. Methods. Thirty-seven subjects (mean age, 48.6 years) were tested by presenting a 60°, 10-second light stimulus (13 log quanta/cm2/s retinal irradiance) and recording pupillary responses for 50 seconds after light cessation. The light stimuli (470 [blue] and 623 [red] nm) were presented by an optical system to one eye after dilation, while the consensual pupil response of the fellow, undilated eye was recorded by infrared pupillometry. Results. A positive PIPR was seen in all subjects tested. The population average of the PIPR for 470-nm light was 1.5 mm (SEM 0.10, P < 0.05) and the net PIPR (blue PIPR minus red PIPR) was 1.4 mm (SEM 0.09, P < 0.0001). The net PIPR correlated positively with baseline pupil diameter (P < 0.05), but not significantly with age, race, or sex (P > 0.05) in the test population. Conclusions. All normal subjects displayed a significant PIPR for a 10-second, 470-nm light stimulus, but not a 623-nm stimulus, which is consistent with the proposed melanopsin-mediated response. In most normal individuals, the amplitude of the PIPR was substantial. This test has the potential to be used as a tool in evaluating subjects with inner retinal dysfunction or melanopsin-related disorders. PMID:20007832
NASA Astrophysics Data System (ADS)
Ma, Chen; Cheng, Dewen; Xu, Chen; Wang, Yongtian
2014-11-01
Fundus camera is a complex optical system for retinal photography, involving illumination and imaging of the retina. Stray light is one of the most significant problems of fundus camera because the retina is so minimally reflective that back reflections from the cornea and any other optical surface are likely to be significantly greater than the light reflected from the retina. To provide maximum illumination to the retina while eliminating back reflections, a novel design of illumination system used in portable fundus camera is proposed. Internal illumination, in which eyepiece is shared by both the illumination system and the imaging system but the condenser and the objective are separated by a beam splitter, is adopted for its high efficiency. To eliminate the strong stray light caused by corneal center and make full use of light energy, the annular stop in conventional illumination systems is replaced by a fiber-coupled, ring-shaped light source that forms an annular beam. Parameters including size and divergence angle of the light source are specially designed. To weaken the stray light, a polarized light source is used, and an analyzer plate is placed after beam splitter in the imaging system. Simulation results show that the illumination uniformity at the fundus exceeds 90%, and the stray light is within 1%. Finally, a proof-of-concept prototype is developed and retinal photos of an ophthalmophantom are captured. The experimental results show that ghost images and stray light have been greatly reduced to a level that professional diagnostic will not be interfered with.
NASA Astrophysics Data System (ADS)
Batra, V.; Kotru, S.
2017-12-01
We report the effects of illumination on the ferroelectric and photovoltaic properties of the Pb0.95La0.05Zr0.54Ti0.46O3 (PLZT) thin film based asymmetric metal/ferroelectric/metal capacitor structure, using Au as a top electrode and Pt as a bottom electrode. Conductive-AFM (atomic force microscopy) measurements demonstrate the evolution of charge carriers in PLZT films on illumination. The capacitance-voltage, the polarization-electric field, and the leakage current-voltage characteristics of the asymmetric Au/PLZT/Pt capacitor are discussed under dark and illuminated conditions. The light generates charge carriers in the film, which increase the coercive field and net remnant polarization and decrease the capacitance. The leakage current of the capacitor increases by an order of magnitude upon illumination. The leakage current data analyzed to study the conduction mechanism shows that the capacitor structure follows the Schottky emission "1/4" law. The illuminated current density-voltage curve of the capacitor shows non-zero photovoltaic parameters. An open circuit voltage (Voc) of -0.19 V and a short circuit current density (Jsc) of 1.48 μA/cm2 were obtained in an unpoled film. However, after positive poling, the illuminated curve shifts towards a higher voltage value resulting in a Voc of -0.93 V. After negative poling, the curve shows no change in the Voc value. For both poling directions, the Jsc values decrease. The photocurrent in the capacitor shows a linear variation with the incident illumination intensity.
Cionni, Robert J.; Pei, Ron; Dimalanta, Ramon; Lubeck, David
2015-01-01
Purpose To evaluate the intensity and stability of the red reflex produced by ophthalmic surgical microscopes with nearly-collimated versus focused illumination systems and to assess surgeon preference in a simulated surgical setting. Methods This two-part evaluation consisted of postproduction surgical video analysis of red reflex intensity and a microscope use and preference survey completed by 13 experienced cataract surgeons. Survey responses were based on bench testing and experience in a simulated surgical setting. A microscope with nearly-collimated beam illumination and two focused beam microscopes were assessed. Results Red reflex intensity and stability were greater with the nearly-collimated microscope illumination system. In the bench testing survey, surgeons reported that the red reflex was maintained over significantly greater distances away from pupillary center, and depth of focus was numerically greater with nearly-collimated illumination relative to focused illumination. Most participating surgeons (≥64%) reported a preference for the microscope with nearly-collimated illumination with regard to red reflex stability, depth of focus, visualization, surgical working distance, and perceived patient comfort. Conclusions The microscope with nearly-collimated illumination produced a more intense and significantly more stable red reflex and was preferred overall by more surgeons. Translational Relevance This is the first report of an attempt to quantify red reflex intensity and stability and to evaluate surgically-relevant parameters between microscope systems. The data and methods presented here may provide a basis for future studies attempting to quantify differences between surgical microscopes that may affect surgeon preference and microscope use in ophthalmic surgery. PMID:26290778
Kim, Min-Jeong; Bang, Woo Suk; Yuk, Hyun-Gyun
2017-04-01
This study evaluated the antibacterial effect of 405 ± 5 nm light emitting diode (LED) illumination against four Salmonella serovars on fresh-cut papaya and on fruit quality at various storage temperatures. To determine the antibacterial mechanism of LED illumination at 0.9 kJ/cm 2 , oxidative damage to DNA and membrane lipids of Salmonella in phosphate-buffered saline solution was measured. The populations of Salmonella on cut fruits were significantly (P < 0.05) reduced by 0.3-1.3 log CFU/cm 2 at chilling temperatures following LED illumination for 36-48 h (1.3-1.7 kJ/cm 2 ). However, at room temperature, bacterial populations increased rapidly to 6.3-7.0 log CFU/cm 2 following LED illumination for 24 h (0.9 kJ/cm 2 ), which was approximately 1.0 log lower than the number of colonies on non-illuminated fruits. Levels of bacterial DNA oxidation significantly increased, whereas lipid peroxidation in bacterial membrane was not observed, suggesting that DNA oxidation contributes to photodynamic inactivation by LED illumination. LED illumination did not adversely affect the physicochemical and nutritional qualities of cut papaya, regardless of storage temperature. These results indicate that a food chiller equipped with 405 ± 5 nm LEDs can preserve fresh-cut papayas in retail stores without deterioration, minimizing the risk of salmonellosis. Copyright © 2016 Elsevier Ltd. All rights reserved.
Gray-world-assumption-based illuminant color estimation using color gamuts with high and low chroma
NASA Astrophysics Data System (ADS)
Kawamura, Harumi; Yonemura, Shunichi; Ohya, Jun; Kojima, Akira
2013-02-01
A new approach is proposed for estimating illuminant colors from color images under an unknown scene illuminant. The approach is based on a combination of a gray-world-assumption-based illuminant color estimation method and a method using color gamuts. The former method, which is one we had previously proposed, improved on the original method that hypothesizes that the average of all the object colors in a scene is achromatic. Since the original method estimates scene illuminant colors by calculating the average of all the image pixel values, its estimations are incorrect when certain image colors are dominant. Our previous method improves on it by choosing several colors on the basis of an opponent-color property, which is that the average color of opponent colors is achromatic, instead of using all colors. However, it cannot estimate illuminant colors when there are only a few image colors or when the image colors are unevenly distributed in local areas in the color space. The approach we propose in this paper combines our previous method and one using high chroma and low chroma gamuts, which makes it possible to find colors that satisfy the gray world assumption. High chroma gamuts are used for adding appropriate colors to the original image and low chroma gamuts are used for narrowing down illuminant color possibilities. Experimental results obtained using actual images show that even if the image colors are localized in a certain area in the color space, the illuminant colors are accurately estimated, with smaller estimation error average than that generated in the conventional method.
Light-Regulated Electrochemical Sensor Array for Efficiently Discriminating Hazardous Gases.
Liang, Hongqiu; Zhang, Xin; Sun, Huihui; Jin, Han; Zhang, Xiaowei; Jin, Qinghui; Zou, Jie; Haick, Hossam; Jian, Jiawen
2017-10-27
Inadequate detection limit and unsatisfactory discrimination features remain the challenging issues for the widely applied electrochemical gas sensors. Quite recently, we confirmed that light-regulated electrochemical reaction significantly enhanced the electrocatalytic activity, and thereby can potentially extend the detection limit to the parts per billion (ppb) level. Nevertheless, impact of the light-regulated electrochemical reaction on response selectivity has been discussed less. Herein, we systematically report on the effect of illumination on discrimination features via design and fabrication of a light-regulated electrochemical sensor array. Upon illumination (light on), response signal to the examined gases (C 3 H 6 , NO, and CO) is selectively enhanced, resulting in the sensor array demonstrating disparate response patterns when compared with that of the sensor array operated at light off. Through processing all the response patterns derived from both light on and light off with a pattern recognition algorithm, a satisfactory discrimination feature is observed. In contrast, apparent mutual interference between NO and CO is found when the sensor array is solely operated without illumination. The impact mechanism of the illumination is studied and it is deduced that the effect of the illumination on the discriminating features can be mainly attributed to the competition of electrocatalytic activity and gas-phase reactivity. If the enhanced electrocatalytic activity (to specific gas) dominates the whole sensing progress, enhancements in the corresponding response signal would be observed upon illumination. Otherwise, illumination gives a negligible impact. Hence, the response signal to part of the examined gases is selectively enhanced by illumination. Conclusively, light-regulated electrochemical reaction would provide an efficient approach to designing future smart sensing devices.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morgan, Cynthia A.; Hurley, Thomas D.
Aldehyde dehydrogenases (ALDH) catalyze the irreversible oxidation of aldehydes to their corresponding carboxylic acid. Alterations in ALDH1A1 activity are associated with such diverse diseases as cancer, Parkinson’s disease, obesity, and cataracts. Inhibitors of ALDH1A1 could aid in illuminating the role of this enzyme in disease processes. However, there are no commercially available selective inhibitors for ALDH1A1. Here we characterize two distinct chemical classes of inhibitors that are selective for human ALDH1A1 compared to eight other ALDH isoenzymes. The prototypical members of each structural class, CM026 and CM037, exhibit sub-micromolar inhibition constants, but have different mechanisms of inhibition. The crystal structuresmore » of these compounds bound to ALDH1A1 demonstrate that they bind within the aldehyde binding pocket of ALDH1A1 and exploit the presence of a unique Glycine residue to achieve their selectivity. Lastly, these two novel and selective ALDH1A1 inhibitors may serve as chemical tools to better understand the contributions of ALDH1A1 to normal biology and to disease states.« less
Derickson, A
1991-06-01
This study examines the early efforts of the United Mine Workers of America to illuminate the problem of occupational respiratory diseases in the coal fields. The union used the hearings of the US Anthracite Coal Strike Commission of 1902-3 to draw public attention to "miners' asthma." In 1915, it began to agitate for the provision of workers' compensation benefits for victims of this disorder. Throughout the 1950s and 1960s, the union's Welfare and Retirement Fund disseminated information on advances in understanding chronic pulmonary diseases of mining. In particular, the miners' fund promoted the British conceptualization of a distinctive coal workers' pneumoconiosis. At the same time, the staff of the union health plan pressed the US Public Health Service and the Pennsylvania Department of Health to investigate the prevalence of occupational respiratory diseases among bituminous miners. Taken together, these endeavors contributed significantly to growing recognition of the severity and extent of this important public health problem and thus helped lay the foundation for the Federal Coal Mine Health and Safety Act of 1969.
Derickson, A
1991-01-01
This study examines the early efforts of the United Mine Workers of America to illuminate the problem of occupational respiratory diseases in the coal fields. The union used the hearings of the US Anthracite Coal Strike Commission of 1902-3 to draw public attention to "miners' asthma." In 1915, it began to agitate for the provision of workers' compensation benefits for victims of this disorder. Throughout the 1950s and 1960s, the union's Welfare and Retirement Fund disseminated information on advances in understanding chronic pulmonary diseases of mining. In particular, the miners' fund promoted the British conceptualization of a distinctive coal workers' pneumoconiosis. At the same time, the staff of the union health plan pressed the US Public Health Service and the Pennsylvania Department of Health to investigate the prevalence of occupational respiratory diseases among bituminous miners. Taken together, these endeavors contributed significantly to growing recognition of the severity and extent of this important public health problem and thus helped lay the foundation for the Federal Coal Mine Health and Safety Act of 1969. Images p784-a p787-a PMID:1827571
Chaufan, Claudia
2007-10-01
I offer a critical perspective on a large-scale population study on gene-environment interactions and common diseases proposed by the US Secretary of Health and Human Services' Advisory Committee on Genetics, Health, and Society (SACGHS). I argue that for scientific and policy reasons this and similar studies have little to add to current knowledge about how to prevent, treat, or decrease inequalities in common diseases, all of which are major claims of the proposal. I use diabetes as an exemplar of the diseases that the study purports to illuminate. I conclude that the question is not whether the study will meet expectations or whether the current emphasis on a genetic paradigm is real or imagined, desirable or not. Rather, the question is why, given the flaws of the science underwriting the study, its assumptions remain unchallenged. Future research should investigate the reasons for this immunity from criticism and for the popularity of this and similar projects among laypersons as well as among intellectuals.
Illuminating Chaucer through Poetry, Manuscript Illuminations, and a Critical Rap Album
ERIC Educational Resources Information Center
Lynch, Tom Liam
2007-01-01
Drawing connections between Chaucer, Eminem, and social issues, New York City high school teacher Tom Liam Lynch helped students become familiar with "The Canterbury Tales." Students wrote poems of rhymed couplets about today's social and political issues, created illuminated manuscripts, and recorded a rap CD. A book and album were…
USDA-ARS?s Scientific Manuscript database
A scalable and modular LED illumination dome for microscopic scientific photography is described and illustrated, and methods for constructing such a dome are detailed. Dome illumination for insect specimens has become standard practice across the field of insect systematics, but many dome designs ...
Evaluation of Particle Image Velocimetry Measurement Using Multi-wavelength Illumination
NASA Astrophysics Data System (ADS)
Lai, HC; Chew, TF; Razak, NA
2018-05-01
In past decades, particle image velocimetry (PIV) has been widely used in measuring fluid flow and a lot of researches have been done to improve the PIV technique. Many researches are conducted on high power light emitting diode (HPLED) to replace the traditional laser illumination system in PIV. As an extended work to the research in PIV illumination system, two high power light emitting diodes (HPLED) with different wavelength are introduced as PIV illumination system. The objective of this research is using dual colours LED to directly replace laser as illumination system in order for a single frame to be captured by a normal camera instead of a high speed camera. Dual colours HPLEDs PIV are capable with single frame double pulses mode which able to plot the velocity vector of the particles after correlation. An illumination system is designed and fabricated and evaluated by measuring water flow in a small tank. The results indicates that HPLEDs promises a few advantages in terms of cost, safety and performance. It has a high potential to be develop into an alternative for PIV in the near future.
Coaxial fundus camera for opthalmology
NASA Astrophysics Data System (ADS)
de Matos, Luciana; Castro, Guilherme; Castro Neto, Jarbas C.
2015-09-01
A Fundus Camera for ophthalmology is a high definition device which needs to meet low light illumination of the human retina, high resolution in the retina and reflection free image1. Those constraints make its optical design very sophisticated, but the most difficult to comply with is the reflection free illumination and the final alignment due to the high number of non coaxial optical components in the system. Reflection of the illumination, both in the objective and at the cornea, mask image quality, and a poor alignment make the sophisticated optical design useless. In this work we developed a totally axial optical system for a non-midriatic Fundus Camera. The illumination is performed by a LED ring, coaxial with the optical system and composed of IR of visible LEDs. The illumination ring is projected by the objective lens in the cornea. The Objective, LED illuminator, CCD lens are coaxial making the final alignment easily to perform. The CCD + capture lens module is a CCTV camera with autofocus and Zoom built in, added to a 175 mm focal length doublet corrected for infinity, making the system easily operated and very compact.
Effects of illumination and packaging on non-heme iron and color attributes of sliced ham.
Li, H; Li, C B; Xu, X L; Zhou, G H
2012-08-01
This study was designed to investigate effects of illumination and packaging on color of cooked cured sliced ham during refrigeration, and the possibility of decomposition of nitrosylheme under light and oxygen exposure. Three illumination levels and three packaging films with different oxygen transmission rates (OTRs) were used in two separate experiments during 35 days storage, and pH value, a* value, nitrosylheme, residual nitrite and non-heme iron were evaluated. Packaging OTRs had significant effects (P<0.01) on a* value, but illumination level and packaging OTR did not affect (P>0.05) nitrosylheme concentration during storage. For both groups, storage time had a significant effect (P<0.01) on a* value and nitrosylheme. Negative relationships between nitrosylheme and nitrite in the illumination group, and between nitrosylheme and non-heme iron in the packaging group were observed. Therefore, illumination level and packaging OTR had limited effects on overall pigment stability, but more discoloration and loss of redness occurred on the surface of products. Copyright © 2012 Elsevier Ltd. All rights reserved.
Museum lighting: Why are some illuminants preferred?
NASA Astrophysics Data System (ADS)
Scuello, Michael; Abramov, Israel; Gordon, James; Weintraub, Steven
2004-02-01
We had shown earlier that viewers prefer to look at artworks under illuminants of ~3600 K. In the latest paper we tested the hypothesis that the preferred illuminant is one that appears neither warm nor cool and repeated the settings at each of four illuminances to test the stability of the findings. Observers looked at a neutral white reflectance standard hung on a matte-gray wall lit by overhead banks of lamps whose combined value could be adjusted continuously between 3000 and 4400 K while illuminance was kept constant. Illuminance ranged from 50 to 2000 lux. Observers adjusted color temperature until they were satisfied that the standard looked neither warm nor cool. The mean for a group of eight observers was approximately 3700, independent of intensity; this corresponds to a dominant wavelength of ~580 nm. In a separate study four observers scaled the apparent warmth or coolness of flashes of equiluminant monochromatic lights; the warm-cool transition was between 560 and 580 nm; warmness was completely predicted by the perceived redness of each light as derived from hue and saturation scaling functions from the same group.
Chang, Chia-Yuan; Lin, Cheng-Han; Lin, Chun-Yu; Sie, Yong-Da; Hu, Yvonne Yuling; Tsai, Sheng-Feng; Chen, Shean-Jen
2018-01-01
A developed temporal focusing-based multiphoton excitation microscope (TFMPEM) has a digital micromirror device (DMD) which is adopted not only as a blazed grating for light spatial dispersion but also for patterned illumination simultaneously. Herein, the TFMPEM has been extended to implement spatially modulated illumination at structured frequency and orientation to increase the beam coverage at the back-focal aperture of the objective lens. The axial excitation confinement (AEC) of TFMPEM can be condensed from 3.0 μm to 1.5 μm for a 50 % improvement. By using the TFMPEM with HiLo technique as two structured illuminations at the same spatial frequency but different orientation, reconstructed biotissue images according to the condensed AEC structured illumination are shown obviously superior in contrast and better scattering suppression. Picture: TPEF images of the eosin-stained mouse cerebellar cortex by conventional TFMPEM (left), and the TFMPEM with HiLo technique as 1.09 μm -1 spatially modulated illumination at 90° (center) and 0° (right) orientations. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Jung, Hyunjun; Kang, Hongki; Nam, Yoonkey
2017-01-01
Light-mediated neuromodulation techniques provide great advantages to investigate neuroscience due to its high spatial and temporal resolution. To generate a spatial pattern of neural activity, it is necessary to develop a system for patterned-light illumination to a specific area. Digital micromirror device (DMD) based patterned illumination system have been used for neuromodulation due to its simple configuration and design flexibility. In this paper, we developed a patterned near-infrared (NIR) illumination system for region specific photothermal manipulation of neural activity using NIR-sensitive plasmonic gold nanorods (GNRs). The proposed system had high power transmission efficiency for delivering power density up to 19 W/mm2. We used a GNR-coated microelectrode array (MEA) to perform biological experiments using E18 rat hippocampal neurons and showed that it was possible to inhibit neural spiking activity of specific area in neural circuits with the patterned NIR illumination. This patterned NIR illumination system can serve as a promising neuromodulation tool to investigate neuroscience in a wide range of physiological and clinical applications. PMID:28663912
Colour perception with changes in levels of illumination
NASA Astrophysics Data System (ADS)
Baah, Kwame F.; Green, Phil; Pointer, Michael
2012-01-01
The perceived colour of a stimulus depends on the conditions under which it is viewed. For colours employed as an important cue or identifier, such as signage and brand colours, colour reproduction tolerances are critically important. Typically, such stimuli would be judged using a known level of illumination but, in the target environment, the level of illumination used to view the samples may be entirely different. The effect of changes in the viewing condition on the perceptibility and acceptability of small colour differences should be understood when such tolerances and associated viewing conditions, are specified. A series of psychophysical experiments was conducted to determine whether changes in illumination level significantly alter acceptability and perceptibility thresholds of uniform colour stimuli. It was found that perceived colour discrimination thresholds varied by up to 2.0 ΔE00. For the perceptual correlate of hue however, this value could be of significance if the accepted error of colour difference was at the threshold, thereby yielding the possibility of rejection with changes in illumination level. Lightness and chroma on the other hand, exhibited greater tolerance and were less likely to be rejected with illuminance changes.
Detection technique for artificially illuminated objects in the outer solar system and beyond.
Loeb, Abraham; Turner, Edwin L
2012-04-01
Existing and planned optical telescopes and surveys can detect artificially illuminated objects, comparable in total brightness to a major terrestrial city, at the outskirts of the Solar System. Orbital parameters of Kuiper belt objects (KBOs) are routinely measured to exquisite precisions of<10(-3). Here, we propose to measure the variation of the observed flux F from such objects as a function of their changing orbital distances D. Sunlight-illuminated objects will show a logarithmic slope α ≡ (d log F/d log D)=-4, whereas artificially illuminated objects should exhibit α=-2. The proposed Large Synoptic Survey Telescope (LSST) and other planned surveys will provide superb data and allow measurement of α for thousands of KBOs. If objects with α=-2 are found, follow-up observations could measure their spectra to determine whether they are illuminated by artificial lighting. The search can be extended beyond the Solar System with future generations of telescopes on the ground and in space that would have the capacity to detect phase modulation due to very strong artificial illumination on the nightside of planets as they orbit their parent stars.
Improving the uniformity of luminous system in radial imaging capsule endoscope system
NASA Astrophysics Data System (ADS)
Ou-Yang, Mang; Jeng, Wei-De
2013-02-01
This study concerns the illumination system in a radial imaging capsule endoscope (RICE). Uniformly illuminating the object is difficult because the intensity of the light from the light emitting diodes (LEDs) varies with angular displacement. When light is emitted from the surface of the LED, it first encounters the cone mirror, from which it is reflected, before directly passing through the lenses and complementary metal oxide semiconductor (CMOS) sensor. The light that is strongly reflected from the transparent view window (TVW) propagates again to the cone mirror, to be reflected and to pass through the lenses and CMOS sensor. The above two phenomena cause overblooming on the image plane. Overblooming causes nonuniform illumination on the image plane and consequently reduced image quality. In this work, optical design software was utilized to construct a photometric model for the optimal design of the LED illumination system. Based on the original RICE model, this paper proposes an optimal design to improve the uniformity of the illumination. The illumination uniformity in the RICE is increased from its original value of 0.128 to 0.69, greatly improving light uniformity.
Reticle stage based linear dosimeter
Berger, Kurt W [Livermore, CA
2007-03-27
A detector to measure EUV intensity employs a linear array of photodiodes. The detector is particularly suited for photolithography systems that includes: (i) a ringfield camera; (ii) a source of radiation; (iii) a condenser for processing radiation from the source of radiation to produce a ringfield illumination field for illuminating a mask; (iv) a reticle that is positioned at the ringfield camera's object plane and from which a reticle image in the form of an intensity profile is reflected into the entrance pupil of the ringfield camera, wherein the reticle moves in a direction that is transverse to the length of the ringfield illumination field that illuminates the reticle; (v) detector for measuring the entire intensity along the length of the ringfield illumination field that is projected onto the reticle; and (vi) a wafer onto which the reticle imaged is projected from the ringfield camera.
Reticle stage based linear dosimeter
Berger, Kurt W.
2005-06-14
A detector to measure EUV intensity employs a linear array of photodiodes. The detector is particularly suited for photolithography systems that includes: (i) a ringfield camera; (ii) a source of radiation; (iii) a condenser for processing radiation from the source of radiation to produce a ringfield illumination field for illuminating a mask; (iv) a reticle that is positioned at the ringfield camera's object plane and from which a reticle image in the form of an intensity profile is reflected into the entrance pupil of the ringfield camera, wherein the reticle moves in a direction that is transverse to the length of the ringfield illumination field that illuminates the reticle; (v) detector for measuring the entire intensity along the length of the ringfield illumination field that is projected onto the reticle; and (vi) a wafer onto which the reticle imaged is projected from the ringfield camera.
An inexpensive programmable illumination microscope with active feedback
Tompkins, Nathan; Fraden, Seth
2016-01-01
We have developed a programmable illumination system capable of tracking and illuminating numerous objects simultaneously using only low-cost and reused optical components. The active feedback control software allows for a closed-loop system that tracks and perturbs objects of interest automatically. Our system uses a static stage where the objects of interest are tracked computationally as they move across the field of view allowing for a large number of simultaneous experiments. An algorithmically determined illumination pattern can be applied anywhere in the field of view with simultaneous imaging and perturbation using different colors of light to enable spatially and temporally structured illumination. Our system consists of a consumer projector, camera, 35-mm camera lens, and a small number of other optical and scaffolding components. The entire apparatus can be assembled for under $4,000. PMID:27642182
Li, Y; Kinoshita, H; Watanabe, T; Irie, S; Shirayone, S; Okazaki, S
2000-07-01
A scanning critical illumination system is designed to couple a synchrotron radiation source to a three-aspherical-mirror imaging system for extreme ultraviolet lithography. A static illumination area of H x V = 8 mm x 3 mm (where H is horizontal and V is vertical) can be obtained. Uniform intensity distribution and a large ring field of H x V = 150 mm x 3 mm can be achieved by scanning of the mirror of the condenser. The coherence factor (sigma) of this illumination system is approximately 0.6, with the same beam divergence in both the horizontal and the vertical directions. We describe the performance of the imaging optics at sigma = 0.6 to confirm that the illumination optics can meet the requirements for three-aspherical-mirror imaging optics with a feature size of 0.06 microm.
Active illumination using a digital micromirror device for quantitative phase imaging.
Shin, Seungwoo; Kim, Kyoohyun; Yoon, Jonghee; Park, YongKeun
2015-11-15
We present a powerful and cost-effective method for active illumination using a digital micromirror device (DMD) for quantitative phase-imaging techniques. Displaying binary illumination patterns on a DMD with appropriate spatial filtering, plane waves with various illumination angles are generated and impinged onto a sample. Complex optical fields of the sample obtained with various incident angles are then measured via Mach-Zehnder interferometry, from which a high-resolution 2D synthetic aperture phase image and a 3D refractive index tomogram of the sample are reconstructed. We demonstrate the fast and stable illumination-control capability of the proposed method by imaging colloidal spheres and biological cells. The capability of high-speed optical diffraction tomography is also demonstrated by measuring 3D Brownian motion of colloidal particles with the tomogram acquisition rate of 100 Hz.
NASA Astrophysics Data System (ADS)
Ando, Yoriko; Sawahata, Hirohito; Kawano, Takeshi; Koida, Kowa; Numano, Rika
2018-02-01
Bundled fiber optics allow in vivo imaging at deep sites in a body. The intrinsic optical contrast detects detailed structures in blood vessels and organs. We developed a bundled-fiber-coupled endomicroscope, enabling stereoscopic three-dimensional (3-D) reflectance imaging with a multipositional illumination scheme. Two illumination sites were attached to obtain reflectance images with left and right illumination. Depth was estimated by the horizontal disparity between the two images under alternative illuminations and was calibrated by the targets with known depths. This depth reconstruction was applied to an animal model to obtain the 3-D structure of blood vessels of the cerebral cortex (Cereb cortex) and preputial gland (Pre gla). The 3-D endomicroscope could be instrumental to microlevel reflectance imaging, improving the precision in subjective depth perception, spatial orientation, and identification of anatomical structures.
The possible ocular hazards of LED dental illumination applications.
Stamatacos, Catherine; Harrison, Janet L
2014-04-01
The use of high-intensity illumination via Light-Emitting Diode (LED) headlamps is gaining in popularity with dentists and student dentists. Practitioners are using LED headlamps together with magnifying loupes, overhead LED illumination and fiber-optic dental handpieces for long periods of time. Although most manufacturers of these LED illuminators advertise that their devices emit "white" light, these still consist of two spectral bands - the blue spectral band, with its peak at 445 nm, and the green with its peak at 555 nm. While manufacturers suggest that their devices emit "white" light, spectral components of LED lights from different companies are significantly different. Dental headlamp manufacturers strive to create a white LED, and they advertise that this type of light emitted from their product offers bright white-light illumination. However, the manufacturing of a white LED light is done through selection of a white LED-type based on the peak blue strength in combination with the green peak strength and thus creating a beam-forming optic, which determines the beam quality. Some LED illuminators have a strong blue-light component versus the green-light component. Blue-light is highly energized and is close in the color spectrum to ultraviolet-light. The hazards of retinal damage with the use of high-intensity blue-lights has been well-documented. There is limited research regarding the possible ocular hazards of usage of high-intensity illuminating LED devices. Furthermore, the authors have found little research, standards, or guidelines examining the possible safety issues regarding the unique dental practice setting consisting of the combined use of LED illumination systems. Another unexamined component is the effect of high-intensity light reflective glare and magnification back to the practitioner's eyes due to the use of water during dental procedures. Based on the result of Dr. Janet Harrison's observations of beginning dental students in a laboratory setting, the aim of this review is to raise awareness of the potential risk for eye damage when singular or combinations of LED illumination are used.
The possible ocular hazards of LED dental illumination applications.
Stamatacos, Catherine; Harrison, Janet L
2013-01-01
The use of high-intensity illumination via Light-Emitting Diode (LED) headlamps is gaining in popularity with dentists and student dentists. Practitioners are using LED headlamps together with magnifying loupes, overhead LED illumination and fiber-optic dental handpieces for long periods of time. Although most manufacturers of these LED illuminators advertise that their devices emit "white" light, these still consist of two spectral bands--the blue spectral band, with its peak at 445 nm, and the green with its peak at 555 nm. While manufacturers suggest that their devices emit "white" light, spectral components of LED lights from different companies are significantly different. Dental headlamp manufacturers strive to create a white LED, and they advertise that this type of light emitted from their product offers bright white-light illumination. However, the manufacturing of a white LED light is done through selection of a white LED-type based on the peak blue strength in combination with the green peak strength and thus creating a beam-forming optic, which determines the beam quality. Some LED illuminators have a strong blue-light component versus the green-light component. Blue-light is highly energized and is close in the color spectrum to ultraviolet-light. The hazards of retinal damage with the use of high-intensity blue-lights has been well-documented. There is limited research regarding the possible ocular hazards of usage of high-intensity illuminating LED devices. Furthermore, the authors have found little research, standards, or guidelines examining the possible safety issues regarding the unique dental practice setting consisting of the combined use of LED illumination systems. Another unexamined component is the effect of high-intensity light reflective glare and magnification back to the practitioner's eyes due to the use of water during dental procedures. Based on the result of Dr. Janet Harrison's observations of beginning dental students in a laboratory setting, the aim of this review is to raise awareness of the potential risk for eye damage when singular or combinations of LED illumination are used.
Laryngoscope illuminance in a tertiary children's hospital: implications for quality laryngoscopy.
Volsky, Peter G; Murphy, Michael K; Darrow, David H
2014-07-01
Laryngoscopes are used by otolaryngologists in a variety of hospital emergency and critical care settings. However, only rarely have quality-related aspects of laryngoscope function and application been studied. To compare the illuminance of laryngoscopes commonly used in a hospital setting to established standards and to assess the potential effects of maintenance practices on laryngoscope illuminance. Observational study of laryngoscope light output and cross-sectional survey of individuals charged with laryngoscope maintenance in a tertiary care children's hospital. Illuminance was chosen as the unit of measurement (lux). Laryngoscopes in the operating room, emergency department, and pediatric intensive care unit were tested according to a standard technique. Illuminance standards for laryngoscopes, published by the International Organization for Standardization (ISO) (500 lux) and in the medical literature (867 lux) were used as benchmarks. Mean laryngoscope illuminance by type of laryngoscope and light source and percentage of laryngoscopes with illuminance below established standards as well as nonfunctioning units. Maintenance practices were evaluated as a secondary outcome. A total of 319 laryngoscopes were tested; 283 were incandescent bulb units used by anesthesiologists, emergency physicians, and intensivists and 36 were xenon light units used by otolaryngologists. Mean (SD) illuminance was 1330 (1160) lux in the incandescent group and 16,600 (13,000) lux in the xenon group (P < .001). Substandard illuminance was observed only in the incandescent group, in 29% to 43% of laryngoscopes; 5% of the incandescent group did not turn on at all. Maintenance of laryngoscopes was performed on a reactive rather than a preventive basis. At our facility, approximately one-third of incandescent laryngoscopes exhibited substandard light output. On the basis of these findings, our hospital has converted all of its incandescent laryngoscopes to light-emitting diode (LED) devices. Such changes, as well as the institution of a quality-control program including scheduled laryngoscope inspection and battery and bulb replacement for incandescent laryngoscopes, may reduce adverse events associated with poor-quality direct laryngoscopy.
Analysis of the color rendition of flexible endoscopes
NASA Astrophysics Data System (ADS)
Murphy, Edward M.; Hegarty, Francis J.; McMahon, Barry P.; Boyle, Gerard
2003-03-01
Endoscopes are imaging devices routinely used for the diagnosis of disease within the human digestive tract. Light is transmitted into the body cavity via incoherent fibreoptic bundles and is controlled by a light feedback system. Fibreoptic endoscopes use coherent fibreoptic bundles to provide the clinician with an image. It is also possible to couple fibreoptic endoscopes to a clip-on video camera. Video endoscopes consist of a small CCD camera, which is inserted into gastrointestinal tract, and associated image processor to convert the signal to analogue RGB video signals. Images from both types of endoscope are displayed on standard video monitors. Diagnosis is dependent upon being able to determine changes in the structure and colour of tissues and biological fluids, and therefore is dependent upon the ability of the endoscope to reproduce the colour of these tissues and fluids with fidelity. This study investigates the colour reproduction of flexible optical and video endoscopes. Fibreoptic and video endoscopes alter image colour characteristics in different ways. The colour rendition of fibreoptic endoscopes was assessed by coupling them to a video camera and applying video colorimetric techniques. These techniques were then used on video endoscopes to assess how the colour rendition of video endoscopes compared with that of optical endoscopes. In both cases results were obtained at fixed illumination settings. Video endoscopes were then assessed with varying levels of illumination. Initial results show that at constant luminance endoscopy systems introduce non-linear shifts in colour. Techniques for examining how this colour shift varies with illumination intensity were developed and both methodology and results will be presented. We conclude that more rigorous quality assurance is required to reduce colour error and are developing calibration procedures applicable to medical endoscopes.
Swanson, William H.; Dul, Mitchell W.; Horner, Douglas G.; Liu, Tiffany; Tran, Irene
2014-01-01
Purpose. To develop perimetric stimuli for which sensitivities are more resistant to reduced retinal illumination than current clinical perimeters. Methods. Fifty-four people free of eye disease were dilated and tested monocularly. For each test, retinal illumination was attenuated with neutral density (ND) filters, and a standard adaptation model was fit to derive mean and SEM for the adaptation parameter (NDhalf). For different stimuli, t-tests on NDhalf were used to assess significance of differences in consistency with Weber's law. Three experiments used custom Gaussian-windowed contrast sensitivity perimetry (CSP). Experiment 1 used CSP-1, with a Gaussian temporal pulse, a spatial frequency of 0.375 cyc/deg (cpd), and SD of 1.5°. Experiment 1 also used the Humphrey Matrix perimeter, with the N-30 test using 0.25 cpd and 25 Hz flicker. Experiment 2 used a rectangular temporal pulse, SDs of 0.25° and 0.5°, and spatial frequencies of 0.0 and 1.0 cpd. Experiment 3 used CSP-2, with 5-Hz flicker, SDs from 0.5° to 1.8°, and spatial frequencies from 0.14 to 0.50 cpd. Results. In Experiment 1, CSP-1 was more consistent with Weber's law (NDhalf ± SEM = 1.86 ± 0.08 log unit) than N-30 (NDhalf = 1.03 ± 0.03 log unit; t > 9, P < 0.0001). All stimuli used in Experiments 2 and 3 had comparable consistency with Weber's law (NDhalf = 1.49–1.69 log unit; t < 2). Conclusions. Perimetric sensitivities were consistent with Weber's law when higher temporal frequencies were avoided. PMID:24370832
Photoinduced currents in pristine and ion irradiated kapton-H polyimide
NASA Astrophysics Data System (ADS)
Sharma, Anu; Sridharbabu, Y.; Quamara, J. K.
2014-10-01
The photoinduced currents in pristine and ion irradiated kapton-H polyimide have been investigated for different applied electric fields at 200°C. Particularly the effect of illumination intensity on the maximum current obtained as a result of photoinduced polarization has been studied. Samples were irradiated by using PELLETRON facility, IUAC, New Delhi. The photo-carrier charge generation depends directly on intensity of illumination. The samples irradiated at higher fluence show a decrease in the peak current with intensity of illumination. The secondary radiation induced crystallinity (SRIC) is responsible for the increase in maximum photoinduced currents generated with intensity of illumination.
Interactive Dynamic Volume Illumination with Refraction and Caustics.
Magnus, Jens G; Bruckner, Stefan
2018-01-01
In recent years, significant progress has been made in developing high-quality interactive methods for realistic volume illumination. However, refraction - despite being an important aspect of light propagation in participating media - has so far only received little attention. In this paper, we present a novel approach for refractive volume illumination including caustics capable of interactive frame rates. By interleaving light and viewing ray propagation, our technique avoids memory-intensive storage of illumination information and does not require any precomputation. It is fully dynamic and all parameters such as light position and transfer function can be modified interactively without a performance penalty.
Full color natural light holographic camera.
Kim, Myung K
2013-04-22
Full-color, three-dimensional images of objects under incoherent illumination are obtained by a digital holography technique. Based on self-interference of two beam-split copies of the object's optical field with differential curvatures, the apparatus consists of a beam-splitter, a few mirrors and lenses, a piezo-actuator, and a color camera. No lasers or other special illuminations are used for recording or reconstruction. Color holographic images of daylight-illuminated outdoor scenes and a halogen lamp-illuminated toy figure are obtained. From a recorded hologram, images can be calculated, or numerically focused, at any distances for viewing.
Label-free super-resolution with coherent nonlinear structured-illumination microscopy
NASA Astrophysics Data System (ADS)
Huttunen, Mikko J.; Abbas, Aazad; Upham, Jeremy; Boyd, Robert W.
2017-08-01
Structured-illumination microscopy enables up to a two-fold lateral resolution improvement by spatially modulating the intensity profile of the illumination beam. We propose a novel way to generalize the concept of structured illumination to nonlinear widefield modalities by spatially modulating, instead of field intensities, the phase of the incident field while interferometrically measuring the complex-valued scattered field. We numerically demonstrate that for second-order and third-order processes an almost four- and six-fold increase in lateral resolution is achievable, respectively. This procedure overcomes the conventional Abbe diffraction limit and provides new possibilities for label-free super-resolution microscopy.
Photoinduced currents in pristine and ion irradiated kapton-H polyimide
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sharma, Anu, E-mail: sharmaanu81@gmail.com; Sridharbabu, Y., E-mail: sharmaanu81@gmail.com; Quamara, J. K., E-mail: sharmaanu81@gmail.com
2014-10-15
The photoinduced currents in pristine and ion irradiated kapton-H polyimide have been investigated for different applied electric fields at 200°C. Particularly the effect of illumination intensity on the maximum current obtained as a result of photoinduced polarization has been studied. Samples were irradiated by using PELLETRON facility, IUAC, New Delhi. The photo-carrier charge generation depends directly on intensity of illumination. The samples irradiated at higher fluence show a decrease in the peak current with intensity of illumination. The secondary radiation induced crystallinity (SRIC) is responsible for the increase in maximum photoinduced currents generated with intensity of illumination.
Cash, R. A.; Narasimhan, V.
2000-01-01
Globalization has led to an increase in the spread of emerging and re-emerging infectious diseases. International efforts are being launched to control their dissemination through global surveillance, a major hindrance to which is the failure of some countries to report outbreaks. Current guidelines and regulations on emerging and re-emerging infectious diseases do not sufficiently take into account the fact that when developing countries report outbreaks they often derive few benefits and suffer disproportionately heavy social and economic consequences. In order to facilitate full participation in global surveillance by developing countries there should be: better and more affordable diagnostic capabilities to allow for timely and accurate information to be delivered in an open and transparent fashion; accurate, less sensationalist news reporting of outbreaks of diseases; adherence by countries to international regulations, including those of the World Trade Organization and the International Health Regulations; financial support for countries that are economically damaged by the diseases in question. The article presents two cases--plague in India and cholera in Peru--that illuminate some of the limitations of current practices. Recommendations are made on measures that could be taken by WHO and the world community to make global surveillance acceptable. PMID:11143197
The topographical model of multiple sclerosis
Cook, Karin; De Nino, Scott; Fletcher, Madhuri
2016-01-01
Relapses and progression contribute to multiple sclerosis (MS) disease course, but neither the relationship between them nor the spectrum of clinical heterogeneity has been fully characterized. A hypothesis-driven, biologically informed model could build on the clinical phenotypes to encompass the dynamic admixture of factors underlying MS disease course. In this medical hypothesis, we put forth a dynamic model of MS disease course that incorporates localization and other drivers of disability to propose a clinical manifestation framework that visualizes MS in a clinically individualized way. The topographical model encapsulates 5 factors (localization of relapses and causative lesions; relapse frequency, severity, and recovery; and progression rate), visualized utilizing dynamic 3-dimensional renderings. The central hypothesis is that, like symptom recrudescence in Uhthoff phenomenon and pseudoexacerbations, progression clinically recapitulates prior relapse symptoms and unmasks previously silent lesions, incrementally revealing underlying lesion topography. The model uses real-time simulation software to depict disease course archetypes and illuminate several well-described but poorly reconciled phenomena including the clinical/MRI paradox and prognostic significance of lesion location and burden on disease outcomes. Utilization of this model could allow for earlier and more clinically precise identification of progressive MS and predictive implications can be empirically tested. PMID:27648465
Urbanization Increases Pathogen Pressure on Feral and Managed Honey Bees.
Youngsteadt, Elsa; Appler, R Holden; López-Uribe, Margarita M; Tarpy, David R; Frank, Steven D
2015-01-01
Given the role of infectious disease in global pollinator decline, there is a need to understand factors that shape pathogen susceptibility and transmission in bees. Here we ask how urbanization affects the immune response and pathogen load of feral and managed colonies of honey bees (Apis mellifera Linnaeus), the predominant economically important pollinator worldwide. Using quantitative real-time PCR, we measured expression of 4 immune genes and relative abundance of 10 honey bee pathogens. We also measured worker survival in a laboratory bioassay. We found that pathogen pressure on honey bees increased with urbanization and management, and the probability of worker survival declined 3-fold along our urbanization gradient. The effect of management on pathogens appears to be mediated by immunity, with feral bees expressing immune genes at nearly twice the levels of managed bees following an immune challenge. The effect of urbanization, however, was not linked with immunity; instead, urbanization may favor viability and transmission of some disease agents. Feral colonies, with lower disease burdens and stronger immune responses, may illuminate ways to improve honey bee management. The previously unexamined effects of urbanization on honey-bee disease are concerning, suggesting that urban areas may favor problematic diseases of pollinators.
Urbanization Increases Pathogen Pressure on Feral and Managed Honey Bees
López-Uribe, Margarita M.; Tarpy, David R.; Frank, Steven D.
2015-01-01
Given the role of infectious disease in global pollinator decline, there is a need to understand factors that shape pathogen susceptibility and transmission in bees. Here we ask how urbanization affects the immune response and pathogen load of feral and managed colonies of honey bees (Apis mellifera Linnaeus), the predominant economically important pollinator worldwide. Using quantitative real-time PCR, we measured expression of 4 immune genes and relative abundance of 10 honey bee pathogens. We also measured worker survival in a laboratory bioassay. We found that pathogen pressure on honey bees increased with urbanization and management, and the probability of worker survival declined 3-fold along our urbanization gradient. The effect of management on pathogens appears to be mediated by immunity, with feral bees expressing immune genes at nearly twice the levels of managed bees following an immune challenge. The effect of urbanization, however, was not linked with immunity; instead, urbanization may favor viability and transmission of some disease agents. Feral colonies, with lower disease burdens and stronger immune responses, may illuminate ways to improve honey bee management. The previously unexamined effects of urbanization on honey-bee disease are concerning, suggesting that urban areas may favor problematic diseases of pollinators. PMID:26536606
Lamy, Philippe; Nordentoft, Iver; Birkenkamp-Demtröder, Karin; Thomsen, Mathilde Borg Houlberg; Villesen, Palle; Vang, Søren; Hedegaard, Jakob; Borre, Michael; Jensen, Jørgen Bjerggaard; Høyer, Søren; Pedersen, Jakob Skou; Ørntoft, Torben F; Dyrskjøt, Lars
2016-10-01
Greater knowledge concerning tumor heterogeneity and clonality is needed to determine the impact of targeted treatment in the setting of bladder cancer. In this study, we performed whole-exome, transcriptome, and deep-focused sequencing of metachronous tumors from 29 patients initially diagnosed with early-stage bladder tumors (14 with nonprogressive disease and 15 with progressive disease). Tumors from patients with progressive disease showed a higher variance of the intrapatient mutational spectrum and a higher frequency of APOBEC-related mutations. Allele-specific expression was also higher in these patients, particularly in tumor suppressor genes. Phylogenetic analysis revealed a common origin of the metachronous tumors, with a higher proportion of clonal mutations in the ancestral branch; however, 19 potential therapeutic targets were identified as both ancestral and tumor-specific alterations. Few subclones were present based on PyClone analysis. Our results illuminate tumor evolution and identify candidate therapeutic targets in bladder cancer. Cancer Res; 76(19); 5894-906. ©2016 AACR. ©2016 American Association for Cancer Research.
Gallenga, P E; Neri, Giampiero; D'Anastasio, Ruggero; Pettorrossi, Vito Enrico; Alfieri, Emilio; Capasso, Luigi
2012-06-01
Charged by the Pope Julius II for painting the Cappella Sistina in Rome (between 1508 and 1512), Michelangelo worked in an elevated scaffolding, in an anomalous position with dyes (including poisoning lead salts) and solvents (such as toxic turpentine) dripping on his face and continuously inhaling, in a dim environment illuminated only with oil lamps and candles, as he described himself and sketched in a sonet addressed to Giovanni da Pistoia. In 1510 he began suffering from eye disease: the main symptom was the necessity to elevate the document he was reading up to the level of his eyes. This defect disappeared few months after he finished painting his masterpiece. We hypothesize that the Michelangelo's eyes disease was a form of acquired and transitory nystagmus induced by the many hours he spent in up gaze, with a skew deviation, a form of ocular tilt reaction resulting from the impairment of spatial sensitivity (inversion illusion) due to the persistence of the artist's head in a horizontal position, looking upward. Copyright © 2012 Elsevier Ltd. All rights reserved.
Mehta, A M; Sonabend, A M; Bruce, J N
2017-04-01
Convection-enhanced delivery (CED) is a promising technique that generates a pressure gradient at the tip of an infusion catheter to deliver therapeutics directly through the interstitial spaces of the central nervous system. It addresses and offers solutions to many limitations of conventional techniques, allowing for delivery past the blood-brain barrier in a targeted and safe manner that can achieve therapeutic drug concentrations. CED is a broadly applicable technique that can be used to deliver a variety of therapeutic compounds for a diversity of diseases, including malignant gliomas, Parkinson's disease, and Alzheimer's disease. While a number of technological advances have been made since its development in the early 1990s, clinical trials with CED have been largely unsuccessful, and have illuminated a number of parameters that still need to be addressed for successful clinical application. This review addresses the physical principles behind CED, limitations in the technique, as well as means to overcome these limitations, clinical trials that have been performed, and future developments.
Man’s Best Friend Becomes Biology’s Best in Show: Genome Analyses in the Domestic Dog*
Parker, Heidi G.; Shearin, Abigail L.; Ostrander, Elaine A.
2012-01-01
In the last five years, canine genetics has gone from map construction to complex disease deconstruction. The availability of a draft canine genome sequence, dense marker chips, and an understanding of the genome architecture has changed the types of studies canine geneticists can undertake. There is now a clear recognition that the dog system offers the opportunity to understand the genetics of both simple and complex traits, including those associated with morphology, disease susceptibility, and behavior. In this review, we summarize recent findings regarding canine domestication and review new information on the organization of the canine genome. We discuss studies aimed at finding genes controlling morphological phenotypes and provide examples of the way such paradigms may be applied to studies of behavior. We also discuss the many ways in which the dog has illuminated our understanding of human disease and conclude with a discussion on where the field is likely headed in the next five years. PMID:21047261
Ma, Ruiqing; Kawamoto, Ken-Ichiro; Shinomori, Keizo
2016-03-01
We explored the color constancy mechanisms of color-deficient observers under red, green, blue, and yellow illuminations. The red and green illuminations were defined individually by the longer axis of the color discrimination ellipsoid measured by the Cambridge Colour Test. Four dichromats (3 protanopes and 1 deuteranope), two anomalous trichromats (2 deuteranomalous observers), and five color-normal observers were asked to complete the color constancy task by making a simultaneous paper match under asymmetrical illuminations in haploscopic view on a monitor. The von Kries adaptation model was applied to estimate the cone responses. The model fits showed that for all color-deficient observers under all illuminations, the adjustment of the S-cone response or blue-yellow chromatically opponent responses modeled with the simple assumption of cone deletion in a certain type (S-M, S-L or S-(L+M)) was consistent with the principle of the von Kries model. The degree of adaptation was similar to that of color-normal observers. The results indicate that the color constancy of color-deficient observers is mediated by the simplified blue-yellow color system with a von Kries-type adaptation effect, even in the case of brightness match, as well as by a possible cone-level adaptation to the S-cone when the illumination produces a strong S-cone stimulation, such as blue illumination.
Karimov, K S; Qazi, I; Khan, T A; Draper, P H; Khalid, F A; Mahroof-Tahir, M
2008-06-01
In this investigation properties of organic semiconductor copper phthalocyanine (CuPc) capacitive humidity and illumination sensors were studied. Organic thin film was deposited by vacuum evaporation on a glass substrate with silver surface-type electrodes to form the Ag/CuPc/Ag sensor. The capacitance of the samples was evaluated at room temperature in the relative humidity range of 35-92%. It was observed that capacitance of the Ag/CuPc/Ag sensor increases with increase in humidity. The ratio of the relative capacitance to relative humidity was about 200. It is assumed that in general the capacitive response of the sensor is associated with polarization due to absorption of water molecules and transfer of charges (electrons and holes). It was observed that under filament lamp illumination of up to 1,000 lx the capacitance of the Ag/CuPc/Ag photo capacitive detectors increased continuously by 20% as compared to dark condition. It is assumed that photo capacitive response of the sensor is associated with polarization due to transfer of photo-generated electrons and holes. An equivalent circuit of the Ag/CuPc/Ag capacitive humidity and illumination sensor was developed. Humidity and illumination dependent capacitance properties of this sensor make it attractive for use in humidity and illumination multi-meters. The sensor may be used in instruments for environmental monitoring of humidity and illumination.
NASA Astrophysics Data System (ADS)
Wang, Pengbo; Gao, Yuan; Chen, Xiao; Li, Ting
2016-03-01
Low-level light therapy (LLLT) has been clinically applied. Recently, more and more cases are reported with positive therapeutic effect by using transcranial light emitting diodes (LEDs) illumination. Here, we developed a LLLT helmet for treating brain injuries based on LED arrays. We designed the LED arrays in circle shape and assembled them in multilayered 3D printed helmet with water-cooling module. The LED arrays can be adjust to touch the head of subjects. A control circuit was developed to drive and control the illumination of the LLLT helmet. The software portion provides the control of on and off of each LED arrays, the setup of illumination parameters, and 3D distribution of LLLT light dose in human subject according to the illumination setups. This LLLT light dose distribution was computed by a Monte Carlo model for voxelized media and the Visible Chinese Human head dataset and displayed in 3D view at the background of head anatomical structure. The performance of the whole system was fully tested. One stroke patient was recruited in the preliminary LLLT experiment and the following neuropsychological testing showed obvious improvement in memory and executive functioning. This clinical case suggested the potential of this Illumination-parameter adjustable and illuminationdistribution visible LED helmet as a reliable, noninvasive, and effective tool in treating brain injuries.
Huang, Shih-Hao; Yu, Chu-Hung; Chien, Yi-Lung
2015-01-01
We have developed a digital light modulation system that utilizes a modified commercial projector equipped with a laser diode as a light source for quantitative measurements of in vivo tissue oxygenation in an unanesthetized zebrafish embryo via phase-based phosphorescence lifetime detection. The oxygen-sensitive phosphorescent probe (Oxyphor G4) was first inoculated into the bloodstream of 48 h post-fertilization (48 hpf) zebrafish embryos via the circulation valley to rapidly disperse probes throughout the embryo. The unanesthetized zebrafish embryo was introduced into the microfluidic device and immobilized on its lateral side by using a pneumatically actuated membrane. By controlling the illumination pattern on the digital micromirror device in the projector, the modulated excitation light can be spatially projected to illuminate arbitrarily-shaped regions of tissue of interest for in vivo oxygen measurements. We have successfully measured in vivo oxygen changes in the cardiac region and cardinal vein of a 48 hpf zebrafish embryo that experience hypoxia and subsequent normoxic conditions. Our proposed platform provides the potential for the real-time investigation of oxygen distribution in tissue microvasculature that relates to physiological stimulation and diseases in a developing organism. PMID:25856326
Alonso-Caneiro, David; Sampson, Danuta M.; Chew, Avenell L.; Collins, Michael J.; Chen, Fred K.
2018-01-01
Adaptive optics flood illumination ophthalmoscopy (AO-FIO) allows imaging of the cone photoreceptor in the living human retina. However, clinical interpretation of the AO-FIO image remains challenging due to suboptimal quality arising from residual uncorrected wavefront aberrations and rapid eye motion. An objective method of assessing image quality is necessary to determine whether an AO-FIO image is suitable for grading and diagnostic purpose. In this work, we explore the use of focus measure operators as a surrogate measure of AO-FIO image quality. A set of operators are tested on data sets acquired at different focal depths and different retinal locations from healthy volunteers. Our results demonstrate differences in focus measure operator performance in quantifying AO-FIO image quality. Further, we discuss the potential application of the selected focus operators in (i) selection of the best quality AO-FIO image from a series of images collected at the same retinal location and (ii) assessment of longitudinal changes in the diseased retina. Focus function could be incorporated into real-time AO-FIO image processing and provide an initial automated quality assessment during image acquisition or reading center grading. PMID:29552404
Real-time yield estimation based on deep learning
NASA Astrophysics Data System (ADS)
Rahnemoonfar, Maryam; Sheppard, Clay
2017-05-01
Crop yield estimation is an important task in product management and marketing. Accurate yield prediction helps farmers to make better decision on cultivation practices, plant disease prevention, and the size of harvest labor force. The current practice of yield estimation based on the manual counting of fruits is very time consuming and expensive process and it is not practical for big fields. Robotic systems including Unmanned Aerial Vehicles (UAV) and Unmanned Ground Vehicles (UGV), provide an efficient, cost-effective, flexible, and scalable solution for product management and yield prediction. Recently huge data has been gathered from agricultural field, however efficient analysis of those data is still a challenging task. Computer vision approaches currently face diffident challenges in automatic counting of fruits or flowers including occlusion caused by leaves, branches or other fruits, variance in natural illumination, and scale. In this paper a novel deep convolutional network algorithm was developed to facilitate the accurate yield prediction and automatic counting of fruits and vegetables on the images. Our method is robust to occlusion, shadow, uneven illumination and scale. Experimental results in comparison to the state-of-the art show the effectiveness of our algorithm.
Implantable photonic devices for improved medical treatments
NASA Astrophysics Data System (ADS)
Sheinman, Victor; Rudnitsky, Arkady; Toichuev, Rakhmanbek; Eshiev, Abdyrakhman; Abdullaeva, Svetlana; Egemkulov, Talantbek; Zalevsky, Zeev
2014-10-01
An evolving area of biomedical research is related to the creation of implantable units that provide various possibilities for imaging, measurement, and the monitoring of a wide range of diseases and intrabody phototherapy. The units can be autonomic or built-in in some kind of clinically applicable implants. Because of specific working conditions in the live body, such implants must have a number of features requiring further development. This topic can cause wide interest among developers of optical, mechanical, and electronic solutions in biomedicine. We introduce preliminary clinical trials obtained with an implantable pill and devices that we have developed. The pill and devices are capable of applying in-body phototherapy, low-level laser therapy, blue light (450 nm) for sterilization, and controlled injection of chemicals. The pill is also capable of communicating with an external control box, including the transmission of images from inside the patient's body. In this work, our pill was utilized for illumination of the sinus-carotid zone in dog and red light influence on arterial pressure and heart rate was demonstrated. Intrabody liver tissue laser ablation and nanoparticle-assisted laser ablation was investigated. Sterilization effect of intrabody blue light illumination was applied during a maxillofacial phlegmon treatment.
Alonso-Caneiro, David; Sampson, Danuta M; Chew, Avenell L; Collins, Michael J; Chen, Fred K
2018-02-01
Adaptive optics flood illumination ophthalmoscopy (AO-FIO) allows imaging of the cone photoreceptor in the living human retina. However, clinical interpretation of the AO-FIO image remains challenging due to suboptimal quality arising from residual uncorrected wavefront aberrations and rapid eye motion. An objective method of assessing image quality is necessary to determine whether an AO-FIO image is suitable for grading and diagnostic purpose. In this work, we explore the use of focus measure operators as a surrogate measure of AO-FIO image quality. A set of operators are tested on data sets acquired at different focal depths and different retinal locations from healthy volunteers. Our results demonstrate differences in focus measure operator performance in quantifying AO-FIO image quality. Further, we discuss the potential application of the selected focus operators in (i) selection of the best quality AO-FIO image from a series of images collected at the same retinal location and (ii) assessment of longitudinal changes in the diseased retina. Focus function could be incorporated into real-time AO-FIO image processing and provide an initial automated quality assessment during image acquisition or reading center grading.
Structured Illumination Microscopy for the Investigation of Synaptic Structure and Function.
Hong, Soyon; Wilton, Daniel K; Stevens, Beth; Richardson, Douglas S
2017-01-01
The neuronal synapse is a primary building block of the nervous system to which alterations in structure or function can result in numerous pathologies. Studying its formation and elimination is the key to understanding how brains are wired during development, maintained throughout adulthood plasticity, and disrupted during disease. However, due to its diffraction-limited size, investigations of the synaptic junction at the structural level have primarily relied on labor-intensive electron microscopy or ultra-thin section array tomography. Recent advances in the field of super-resolution light microscopy now allow researchers to image synapses and associated molecules with high-spatial resolution, while taking advantage of the key characteristics of light microscopy, such as easy sample preparation and the ability to detect multiple targets with molecular specificity. One such super-resolution technique, Structured Illumination Microscopy (SIM), has emerged as an attractive method to examine synapse structure and function. SIM requires little change in standard light microscopy sample preparation steps, but results in a twofold improvement in both lateral and axial resolutions compared to widefield microscopy. The following protocol outlines a method for imaging synaptic structures at resolutions capable of resolving the intricacies of these neuronal connections.
Subsurface Optical Microscopy of Coarse Grain Spinels. Phase 1
2013-12-01
A 456 nm LED line bar illuminated in figure 15 and a Xenon fiber optic bar illuminator is shown for figure 16. The optical in situ or subsurface ... imaging of coarse grain spinels and AlONs is optically more complex than expected. An overhead view of the side illumination field is shown in figure 20
NASA Technical Reports Server (NTRS)
Stoker, Carol R.; Rages, Kathy
2002-01-01
We correct spectra of Yogi to remove diffuse illumination and show that the part of Yogi facing the wind is less red than other faces of the rock. Our method eliminates ambiguity in interpreting spectra obtained under Mars illumination conditions. Additional information is contained in the original extended abstract.
Transfer between Pose and Illumination Training in Face Recognition
ERIC Educational Resources Information Center
Liu, Chang Hong; Bhuiyan, Md. Al-Amin; Ward, James; Sui, Jie
2009-01-01
The relationship between pose and illumination learning in face recognition was examined in a yes-no recognition paradigm. The authors assessed whether pose training can transfer to a new illumination or vice versa. Results show that an extensive level of pose training through a face-name association task was able to generalize to a new…
Colour differences in Caucasian and Oriental women's faces illuminated by white LED sources.
Melgosa, M; Richard, N; Fernández-Maloigne, C; Xiao, K; de Clermont-Gallerande, H; Jost-Boissard, S; Okajima, K
2018-04-10
To provide an approach to facial contrast, analysing CIELAB colour differences (ΔE* ab,10 ) and its components in women's faces from two different ethnic groups, illuminated by modern white light-emitting diodes (LEDs) or traditional illuminants recommended by the International Commission on Illumination (CIE). We performed spectrophotometric measurements of spectral reflectance factors on forehead and cheek of 87 young healthy women (50 Caucasians and 37 Orientals), plus 5 commercial red lipsticks. We considered a set of 10 white LED illuminants, representative of technologies currently available on the market, plus 8 main illuminants currently recommended by the CIE, representative of conventional incandescent, daylight, and fluorescent light sources. Under each of these 18 illuminants we analysed the magnitude and components of ΔE* ab,10 between Caucasian and Oriental women (considering cheek and forehead), as well as for cheek-forehead and cheek-lipsticks in Caucasian and Oriental women. Colour-inconstancy indices for cheek, forehead, and lipsticks were computed, assuming D65 and A as reference illuminants. ΔE* ab,10 between forehead and cheek were quantitatively and qualitatively different in Orientals and Caucasians, but discrepancies with respect to average values for 18 illuminants were small (1.5% and 5.0% for Orientals and Caucasians, respectively). ΔE* ab,10 between Caucasians and Orientals were also quantitatively and qualitatively different both for forehead and cheek, and discrepancies with respect to average values were again small (1.0% and 3.9% for forehead and cheek, respectively). ΔE* ab,10 between lipsticks and cheek were at least 2 times higher than those between forehead and cheek. Regarding ΔE* ab,10 between lipsticks and cheeks, discrepancies with respect to average values were in the range 1.5% - 12.3%, although higher values of up to 54.2% were found for a white RGB LED. This white RGB LED provided the highest average colour-inconstancy indices: 17.1 and 11.5 CIELAB units, under reference illuminants D65 and A, respectively. Colour contrasts in women's faces under CIE standard illuminants for outdoor and indoor conditions may be strongly altered by using specific white LEDs. More research needs to be done on the impact of spectral power distribution of light sources with high colour rendering indices on visual colour appearance of cosmetic products. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Generation of realistic scene using illuminant estimation and mixed chromatic adaptation
NASA Astrophysics Data System (ADS)
Kim, Jae-Chul; Hong, Sang-Gi; Kim, Dong-Ho; Park, Jong-Hyun
2003-12-01
The algorithm of combining a real image with a virtual model was proposed to increase the reality of synthesized images. Currently, synthesizing a real image with a virtual model facilitated the surface reflection model and various geometric techniques. In the current methods, the characteristics of various illuminants in the real image are not sufficiently considered. In addition, despite the chromatic adaptation plays a vital role for accommodating different illuminants in the two media viewing conditions, it is not taken into account in the existing methods. Thus, it is hardly to get high-quality synthesized images. In this paper, we proposed the two-phase image synthesis algorithm. First, the surface reflectance of the maximum high-light region (MHR) was estimated using the three eigenvectors obtained from the principal component analysis (PCA) applied to the surface reflectances of 1269 Munsell samples. The combined spectral value, i.e., the product of surface reflectance and the spectral power distributions (SPDs) of an illuminant, of MHR was then estimated using the three eigenvectors obtained from PCA applied to the products of surface reflectances of Munsell 1269 samples and the SPDs of four CIE Standard Illuminants (A, C, D50, D65). By dividing the average combined spectral values of MHR by the average surface reflectances of MHR, we could estimate the illuminant of a real image. Second, the mixed chromatic adaptation (S-LMS) using an estimated and an external illuminants was applied to the virtual-model image. For evaluating the proposed algorithm, experiments with synthetic and real scenes were performed. It was shown that the proposed method was effective in synthesizing the real and the virtual scenes under various illuminants.
Herbst, Kristina; Sander, Birgit; Lund-Andersen, Henrik; Wegener, Marianne; Hannibal, Jens; Milea, Dan
2013-01-01
The intrinsically photosensitive retinal ganglion cells (ipRGCs) express the photopigment melanopsin, which is sensitive to blue light. Previous chromatic pupillometry studies have shown that the post-illumination response is considered an indicator of the melanopsin activation. The aim of this study was to investigate the ipRGC mediated pupil response in patients with a unilateral non-arteritic anterior ischemic optic neuropathy (NAION). Consensual pupil responses during and after exposure to continuous 20 s blue (470 nm) or red (660 nm) light of high intensity (300 cd/m2) were recorded in each eye for 10 patients. Comparisons were performed both intra-individually (affected versus non-affected eyes) and inter-individually (compared with healthy controls). The pupil response was calculated both during the illumination and during the post-illumination phase. The pupil responses to blue and red colors were significantly reduced in the NAION-affected eyes, compared with the fellow non-affected eyes. When comparing the affected eyes with the healthy control eyes, the post-illumination responses were not significantly different. In addition, the post-illumination pupil responses after blue light exposure were increased in the fellow non-affected patients’ eyes, compared with the healthy controls. However, significance was only reached for the late post-illumination response. In conclusion, chromatic pupillometry disclosed reduced post-illumination pupil responses in the NAION-affected eyes, compared with the non-affected fellow eyes, suggesting dysfunction of the ipRGCs. Compared with the responses of the healthy controls, the blue light post-illumination pupil responses were similar in the affected eyes and increased in the fellow non-affected eyes. This suggests a possible adaptive phenomenon, involving the ipRGCs of both eyes after unilateral NAION. PMID:23717301
Pellagatti, Andrea; Boultwood, Jacqueline
2017-01-01
Splicing factor gene mutations are the most frequent mutations found in patients with the myeloid malignancy myelodysplastic syndrome (MDS), suggesting that spliceosomal dysfunction plays a major role in disease pathogenesis. The aberrantly spliced target genes and deregulated cellular pathways associated with the commonly mutated splicing factor genes in MDS (SF3B1, SRSF2 and U2AF1) are being identified, illuminating the molecular mechanisms underlying MDS. Emerging data from mouse modeling studies indicate that the presence of splicing factor gene mutations can lead to bone marrow hematopoietic stem/myeloid progenitor cell expansion, impaired hematopoiesis and dysplastic differentiation that are hallmarks of MDS. Importantly, recent evidence suggests that spliceosome inhibitors and splicing modulators may have therapeutic value in the treatment of splicing factor mutant myeloid malignancies. Copyright © 2016 Elsevier Ltd. All rights reserved.
Genetic treatment of a molecular disorder: gene therapy approaches to sickle cell disease
Hoban, Megan D.; Bauer, Daniel E.
2016-01-01
Effective medical management for sickle cell disease (SCD) remains elusive. As a prevalent and severe monogenic disorder, SCD has been long considered a logical candidate for gene therapy. Significant progress has been made in moving toward this goal. These efforts have provided substantial insight into the natural regulation of the globin genes and illuminated challenges for genetic manipulation of the hematopoietic system. The initial γ-retroviral vectors, next-generation lentiviral vectors, and novel genome engineering and gene regulation approaches each share the goal of preventing erythrocyte sickling. After years of preclinical studies, several clinical trials for SCD gene therapies are now open. This review focuses on progress made toward achieving gene therapy, the current state of the field, consideration of factors that may determine clinical success, and prospects for future development. PMID:26758916
Method for detection of dental caries and periodontal disease using optical imaging
Nathel, Howard; Kinney, John H.; Otis, Linda L.
1996-01-01
A method for detecting the presence of active and inactive caries in teeth and diagnosing periodontal disease uses non-ionizing radiation with techniques for reducing interference from scattered light. A beam of non-ionizing radiation is divided into sample and reference beams. The region to be examined is illuminated by the sample beam, and reflected or transmitted radiation from the sample is recombined with the reference beam to form an interference pattern on a detector. The length of the reference beam path is adjustable, allowing the operator to select the reflected or transmitted sample photons that recombine with the reference photons. Thus radiation scattered by the dental or periodontal tissue can be prevented from obscuring the interference pattern. A series of interference patterns may be generated and interpreted to locate dental caries and periodontal tissue interfaces.
Contrast sensitivity perimetry data from adults free of eye disease.
Swanson, William H; Dul, Mitchell W; Horner, Douglas G; Malinovsky, Victor E
2016-09-01
This data article contains data referenced in "Individual Differences in the Shape of the Nasal Visual Field" [1]. The data were gathered from volunteers free of eye disease ages 21-85 who were tested with Contrast Sensitivity Perimetry (CSP), which uses a stimulus resistant to effects of defocus and reduced retinal illumination. Some subjects were tested only once or a few times, and others were part of a longitudinal cohort with as many as 10 tests. Parameters from maximum likelihood estimation of psychophysical threshold at each tested location are included in the data file, along with the participant׳s sex, age at time of test, the center of their physiological blind spot, the duration of test, the time of day that the test was begun, and the starting contrast used for the psychophysical staircases.
Minimally invasive optical biopsy for oximetry
NASA Astrophysics Data System (ADS)
van der Putten, Marieke A.; Brewer, James M.; Harvey, Andrew R.
2017-02-01
The study of localised oxygen saturation in blood vessels can shed light on the etiology and progression of many diseases with which hypoxia is associated. For example, hypoxia in the tendon has been linked to early stages of rheumatoid arthritis, an auto-immune inflammatory disease. Vascular oximetry of deep tissue presents significant challenges as vessels are not optically accessible. In this paper, we present a novel multispectral imaging technique for vascular oximetry, and recent developments made towards its adaptation for minimally invasive imaging. We present proof-of-concept of the system and illumination scheme as well as the analysis technique. We present results of a validation study performed in vivo on mice with acutely inflamed tendons. Adaptation of the technique for minimally invasive microendoscopy is also presented, along with preliminary results of minimally invasive ex vivo vascular oximetry.
Li, Baopu; Meng, Max Q-H
2012-05-01
Tumor in digestive tract is a common disease and wireless capsule endoscopy (WCE) is a relatively new technology to examine diseases for digestive tract especially for small intestine. This paper addresses the problem of automatic recognition of tumor for WCE images. Candidate color texture feature that integrates uniform local binary pattern and wavelet is proposed to characterize WCE images. The proposed features are invariant to illumination change and describe multiresolution characteristics of WCE images. Two feature selection approaches based on support vector machine, sequential forward floating selection and recursive feature elimination, are further employed to refine the proposed features for improving the detection accuracy. Extensive experiments validate that the proposed computer-aided diagnosis system achieves a promising tumor recognition accuracy of 92.4% in WCE images on our collected data.
Improvement of unbalanced illumination induced telecentricity within the exposure slit
NASA Astrophysics Data System (ADS)
Jang, Jonghoon; Lee, ByeongSoo; Kang, Young Seog; Chang, Chansam; Kong, Jeong-Heung; Kim, Young Ha; Bouman, Wim; de Graaf, Roelof; Weichselbaum, Stefan; Droste, Richard; de Boeij, Wim P.; van Bussel, Bart; Neefs, Patrick; Rijke, Arij
2016-03-01
Adjustment and control of the illumination pupil asymmetry is relevant for wafer alignment and overlay of lithography tools. Pupil asymmetries can cause a tilt in aerial image (Aerial Image Tilt, or AIT). This AIT, combined with a focus offset, leads to a horizontal image shift. Pupil asymmetries can be related to a shift of the entire illumination pupil (geometrical telecentricity) caused by illuminator misalign. Another type of pupil asymmetry is energetic imbalance (quantified by pupil Center of Gravity, COG). The scanner can show pupil variation across the exposure slit. In general the COG at the edge of the slit is often worse than in the center part of the slit. Recently, ASML has released the NXT:1980Di that is equipped with an enhanced illuminator to improve pupil COG variation across the slit. In this paper we explore the performance of this scanner system and show that the AIT variation across the slit is also reduced significantly.
Study on Formulation of Optimum Lighting-system for Purchasing Power at Stores
NASA Astrophysics Data System (ADS)
Fujita, Hiroki; Nakashima, Yoshio; Takamatsu, Mamoru; Oota, Masaaki; Sawa, Kazuhiro
In store lighting, difference in the look-and-feel of foods gives effects on the purchasing power of customers. This study conducted the digitalization and quantification on the effects of the variation of light-source color and illuminance used for lighting foods on image recognition on foods. As a result, it was clarified that when meat was illuminated with the light source of “pink” or “faint pink,” image evaluation on foods became higher. In addition, when illuminance increase was applied to these two light-source colors, image evaluation on “faint pink” became further higher. The reason is supposed to be that the redness of meat increased, which may have enhanced fresher impression. From this study, it has been clarified that the light-source color and illuminance optimum for each food are variant. The results show that lighting foods with the optimum light-source color and illuminance can make foods look better.
Active illuminated space object imaging and tracking simulation
NASA Astrophysics Data System (ADS)
Yue, Yufang; Xie, Xiaogang; Luo, Wen; Zhang, Feizhou; An, Jianzhu
2016-10-01
Optical earth imaging simulation of a space target in orbit and it's extraction in laser illumination condition were discussed. Based on the orbit and corresponding attitude of a satellite, its 3D imaging rendering was built. General simulation platform was researched, which was adaptive to variable 3D satellite models and relative position relationships between satellite and earth detector system. Unified parallel projection technology was proposed in this paper. Furthermore, we denoted that random optical distribution in laser-illuminated condition was a challenge for object discrimination. Great randomicity of laser active illuminating speckles was the primary factor. The conjunction effects of multi-frame accumulation process and some tracking methods such as Meanshift tracking, contour poid, and filter deconvolution were simulated. Comparison of results illustrates that the union of multi-frame accumulation and contour poid was recommendable for laser active illuminated images, which had capacities of high tracking precise and stability for multiple object attitudes.
Integral freeform illumination lens design of LED based pico-projector.
Zhao, Shuang; Wang, Kai; Chen, Fei; Qin, Zong; Liu, Sheng
2013-05-01
In this paper, an illumination lens design for a LED-based pico-projector is presented. Different from the traditional illumination systems composed by lens group, the integral illumination lens consists of a total internal reflector (TIR) and a freeform surface. TIR acts as collimation lens and its top surface formed by a freeform surface reshapes the nonuniform circular light pattern generated by TIR to be rectangular and uniform. Diameter and height of the lens are 16 and 10 mm, respectively. An optimization method to deal with the problem of extended light source is also presented in detail in this paper. According to the simulation results of the final optimized lens, 77% (neglecting the effect of polarization) of the power of light source is collected on liquid crystal on silicon panel with a 16∶9 ratio and illumination uniformity achieves 92%.
Critical illumination condenser for x-ray lithography
Cohen, S.J.; Seppala, L.G.
1998-04-07
A critical illumination condenser system is disclosed, particularly adapted for use in extreme ultraviolet (EUV) projection lithography based on a ring field imaging system and a laser produced plasma source. The system uses three spherical mirrors and is capable of illuminating the extent of the mask plane by scanning either the primary mirror or the laser plasma source. The angles of radiation incident upon each mirror of the critical illumination condenser vary by less than eight (8) degrees. For example, the imaging system in which the critical illumination condenser is utilized has a 200 {micro}m source and requires a magnification of 26. The three spherical mirror system constitutes a two mirror inverse Cassegrain, or Schwarzschild configuration, with a 25% area obstruction (50% linear obstruction). The third mirror provides the final pupil and image relay. The mirrors include a multilayer reflective coating which is reflective over a narrow bandwidth. 6 figs.
RESPIRATION AND INTENSITY DEPENDENCE OF PHOTOSYNTHESIS IN CHLORELLA
Brackett, Frederick S.; Olson, Rodney A.; Crickard, Robert G.
1953-01-01
1. Respiration changes as a result of illumination. 2. In the absence of glucose or other supply of substrate, respiration decays in the dark showing at least two types—a fast decay in a few minutes and a slow decay lasting hours. 3. Respiratory response to illumination is delayed. 4. Intermittent illumination (in the absence of glucose, etc.) produces a periodic variation in respiration with a delay or phase lag. 5. Periodic variation of respiration may produce a higher average value in the dark than in the light due to the lag and depending upon the period of intermittent illumination. 6. Based upon average respiration values our data confirm the Kok effect. 7. Interpolated values of respiration, however, result in photosynthetic rates which are linearly dependent upon intensity of illumination. 8. Thus the quantum efficiency is found to be independent of intensity, over the wide range of intensities investigated. PMID:13035068
Kiyokawa, Masatoshi; Sakuma, Toshiro; Hatano, Noriko; Mizota, Atsushi; Tanaka, Minoru
2009-06-01
The purpose of this article is to report the characteristics and advantages of using a newly designed quartz contact lens with slit illumination from an operating microscope for intraocular surgery. The new contact lens is made of quartz. The lens is convex-concave and is used in combination with slit illumination from an operating microscope. The optical properties of quartz make this lens less reflective with greater transmittance. The combination of a quartz contact lens with slit illumination provided a brighter and wider field of view than conventional lenses. This system enabled us to perform bimanual vitrectomy and scleral buckling surgery without indirect ophthalmoscope. Small intraocular structures in the posterior pole or in the periphery were detected more easily. In conclusion, the newly designed quartz lens with slit beam illumination from an operating microscope provided a bright, clear and wide surgical field, and allowed intraocular surgery to be performed more easily.
Supercontinuum as a light source for miniaturized endoscopes.
Lu, M K; Lin, H Y; Hsieh, C C; Kao, F J
2016-09-01
In this work, we have successfully implemented supercontinuum based illumination through single fiber coupling. The integration of a single fiber illumination with a miniature CMOS sensor forms a very slim and powerful camera module for endoscopic imaging. A set of tests and in vivo animal experiments are conducted accordingly to characterize the corresponding illuminance, spectral profile, intensity distribution, and image quality. The key illumination parameters of the supercontinuum, including color rendering index (CRI: 72%~97%) and correlated color temperature (CCT: 3,100K~5,200K), are modified with external filters and compared with those from a LED light source (CRI~76% & CCT~6,500K). The very high spatial coherence of the supercontinuum allows high luminosity conduction through a single multimode fiber (core size~400μm), whose distal end tip is attached with a diffussion tip to broaden the solid angle of illumination (from less than 10° to more than 80°).
Low-Light-Level InGaAs focal plane arrays with and without illumination
NASA Astrophysics Data System (ADS)
Macdougal, Michael; Geske, Jon; Wang, Chad; Follman, David
2010-04-01
Short wavelength IR imaging using InGaAs-based FPAs is shown. Aerius demonstrates low dark current in InGaAs detector arrays with 15 μm pixel pitch. The same material is mated with a 640x 512 CTIA-based readout integrated circuit. The resulting FPA is capable of imaging photon fluxes with wavelengths between 1 and 1.6 microns at low light levels. The mean dark current density on the FPAs is extremely low at 0.64 nA/cm2 at 10°C. Noise due to the readout can be reduced from 95 to 57 electrons by using off-chip correlated double sampling (CDS). In addition, Aerius has developed laser arrays that provide flat illumination in scenes that are normally light-starved. The illuminators have 40% wall-plug efficiency and provide speckle-free illumination, provide artifact-free imagery versus conventional laser illuminators.
Color constancy by characterization of illumination chromaticity
NASA Astrophysics Data System (ADS)
Nikkanen, Jarno T.
2011-05-01
Computational color constancy algorithms play a key role in achieving desired color reproduction in digital cameras. Failure to estimate illumination chromaticity correctly will result in invalid overall colour cast in the image that will be easily detected by human observers. A new algorithm is presented for computational color constancy. Low computational complexity and low memory requirement make the algorithm suitable for resource-limited camera devices, such as consumer digital cameras and camera phones. Operation of the algorithm relies on characterization of the range of possible illumination chromaticities in terms of camera sensor response. The fact that only illumination chromaticity is characterized instead of the full color gamut, for example, increases robustness against variations in sensor characteristics and against failure of diagonal model of illumination change. Multiple databases are used in order to demonstrate the good performance of the algorithm in comparison to the state-of-the-art color constancy algorithms.
Low energy sign illumination system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Minogue, R.W.
A low energy sign contruction is illustrated for illumination of signs of the type having translucent illuminated faces. An opaque sign border is bridged by a reflector extending generally parallel to the illuminated face and having a truncated sawtooth profile. For single sided signs, one set of sawtooth points is truncated; for dual sided signs, both set of sawtooth points are truncated. Bayonet mounted lighting sockets are mounted at apertures in the respective truncations and utilize the metallic reflective surface as one side of a low voltage (10.5-volt) ac circuit. The reflector forms a cooled heat sink mounting the bulbsmore » as well as a supporting matrix. The lamps, as mounted to this supporting matrix, are typically spaced at distances which do not exceed twice the distance of the lamp filament to the translucent face. By the expedient of using 14-V lamps, prolonged lamp life with low energy illumination results.« less
Critical illumination condenser for x-ray lithography
Cohen, Simon J.; Seppala, Lynn G.
1998-01-01
A critical illumination condenser system, particularly adapted for use in extreme ultraviolet (EUV) projection lithography based on a ring field imaging system and a laser produced plasma source. The system uses three spherical mirrors and is capable of illuminating the extent of the mask plane by scanning either the primary mirror or the laser plasma source. The angles of radiation incident upon each mirror of the critical illumination condenser vary by less than eight (8) degrees. For example, the imaging system in which the critical illumination condenser is utilized has a 200 .mu.m source and requires a magnification of 26.times.. The three spherical mirror system constitutes a two mirror inverse Cassegrain, or Schwarzschild configuration, with a 25% area obstruction (50% linear obstruction). The third mirror provides the final pupil and image relay. The mirrors include a multilayer reflective coating which is reflective over a narrow bandwidth.
Pulsed laser linescanner for a backscatter absorption gas imaging system
Kulp, Thomas J.; Reichardt, Thomas A.; Schmitt, Randal L.; Bambha, Ray P.
2004-02-10
An active (laser-illuminated) imaging system is described that is suitable for use in backscatter absorption gas imaging (BAGI). A BAGI imager operates by imaging a scene as it is illuminated with radiation that is absorbed by the gas to be detected. Gases become "visible" in the image when they attenuate the illumination creating a shadow in the image. This disclosure describes a BAGI imager that operates in a linescanned manner using a high repetition rate pulsed laser as its illumination source. The format of this system allows differential imaging, in which the scene is illuminated with light at least 2 wavelengths--one or more absorbed by the gas and one or more not absorbed. The system is designed to accomplish imaging in a manner that is insensitive to motion of the camera, so that it can be held in the hand of an operator or operated from a moving vehicle.
On analyzing colour constancy approach for improving SURF detector performance
NASA Astrophysics Data System (ADS)
Zulkiey, Mohd Asyraf; Zaki, Wan Mimi Diyana Wan; Hussain, Aini; Mustafa, Mohd. Marzuki
2012-04-01
Robust key point detector plays a crucial role in obtaining a good tracking feature. The main challenge in outdoor tracking is the illumination change due to various reasons such as weather fluctuation and occlusion. This paper approaches the illumination change problem by transforming the input image through colour constancy algorithm before applying the SURF detector. Masked grey world approach is chosen because of its ability to perform well under local as well as global illumination change. Every image is transformed to imitate the canonical illuminant and Gaussian distribution is used to model the global change. The simulation results show that the average number of detected key points have increased by 69.92%. Moreover, the average of improved performance cases far out weight the degradation case where the former is improved by 215.23%. The approach is suitable for tracking implementation where sudden illumination occurs frequently and robust key point detection is needed.
White constancy method for mobile displays
NASA Astrophysics Data System (ADS)
Yum, Ji Young; Park, Hyun Hee; Jang, Seul Ki; Lee, Jae Hyang; Kim, Jong Ho; Yi, Ji Young; Lee, Min Woo
2014-03-01
In these days, consumer's needs for image quality of mobile devices are increasing as smartphone is widely used. For example, colors may be perceived differently when displayed contents under different illuminants. Displayed white in incandescent lamp is perceived as bluish, while same content in LED light is perceived as yellowish. When changed in perceived white under illuminant environment, image quality would be degraded. Objective of the proposed white constancy method is restricted to maintain consistent output colors regardless of the illuminants utilized. Human visual experiments are performed to analyze viewers'perceptual constancy. Participants are asked to choose the displayed white in a variety of illuminants. Relationship between the illuminants and the selected colors with white are modeled by mapping function based on the results of human visual experiments. White constancy values for image control are determined on the predesigned functions. Experimental results indicate that propsed method yields better image quality by keeping the display white.
Laser Illumination Modality of Photoacoustic Imaging Technique for Prostate Cancer
NASA Astrophysics Data System (ADS)
Peng, Dong-qing; Peng, Yuan-yuan; Guo, Jian; Li, Hui
2016-02-01
Photoacoustic imaging (PAI) has recently emerged as a promising imaging technique for prostate cancer. But there was still a lot of challenge in the PAI for prostate cancer detection, such as laser illumination modality. Knowledge of absorbed light distribution in prostate tissue was essential since the distribution characteristic of absorbed light energy would influence the imaging depth and range of PAI. In order to make a comparison of different laser illumination modality of photoacoustic imaging technique for prostate cancer, optical model of human prostate was established and combined with Monte Carlo simulation method to calculate the light absorption distribution in the prostate tissue. Characteristic of light absorption distribution of transurethral and trans-rectal illumination case, and of tumor at different location was compared with each other.The relevant conclusions would be significant for optimizing the light illumination in a PAI system for prostate cancer detection.
Development of electroluminescence based pressure-sensitive paint system.
Iijima, Yoshimi; Sakaue, Hirotaka
2011-01-01
We introduce a pressure-sensitive paint (PSP) measurement system based on an electroluminescence (EL) as a surface illumination. This consists of an inorganic EL as the illumination, a short-pass filter, and a platinum-porphyrin based PSP. The short-pass filter, which passes below 500 nm, was used to separate an overlay of the EL illumination and the PSP emission. The EL shows an opposite temperature dependency to that of the PSP. It gives a uniform illumination compared to that of a point illumination source such as a xenon lamp. Under atmospheric conditions, the resultant EL-PSP system reduces the temperature dependency by 54% compared to that of a conventional PSP system. An application of the EL-PSP system to a sonic jet impingement shows that the system demonstrated its reduction of the temperature dependency by 75% in a pressure measurement and reduces an image misalignment error.
Illumination from space with orbiting solar-reflector spacecraft
NASA Technical Reports Server (NTRS)
Canady, J. E., Jr.; Allen, J. L., Jr.
1982-01-01
The feasibility of using orbiting mirrors to reflect sunlight to Earth for several illumination applications is studied. A constellation of sixteen 1 km solar reflector spacecraft in geosynchronous orbit can illuminate a region 333 km in diameter to 8 lux, which is brighter than most existing expressway lighting systems. This constellation can serve one region all night long or can provide illumination during mornings and evenings to five regions across the United States. Preliminary cost estimates indicate such an endeavor is economically feasible. The studies also explain how two solar reflectors can illuminate the in-orbit nighttime operations of Space Shuttle. An unfurlable, 1 km diameter solar reflector spacecraft design concept was derived. This spacecraft can be packaged in the Space, Shuttle, transported to low Earth orbit, unfurled, and solar sailed to operational orbits up to geosynchronous. The necessary technical studies and improvements in technology are described, and potential environmental concerns are discussed.
GLADIATOR: a global approach for elucidating disease modules.
Silberberg, Yael; Kupiec, Martin; Sharan, Roded
2017-05-26
Understanding the genetic basis of disease is an important challenge in biology and medicine. The observation that disease-related proteins often interact with one another has motivated numerous network-based approaches for deciphering disease mechanisms. In particular, protein-protein interaction networks were successfully used to illuminate disease modules, i.e., interacting proteins working in concert to drive a disease. The identification of these modules can further our understanding of disease mechanisms. We devised a global method for the prediction of multiple disease modules simultaneously named GLADIATOR (GLobal Approach for DIsease AssociaTed mOdule Reconstruction). GLADIATOR relies on a gold-standard disease phenotypic similarity to obtain a pan-disease view of the underlying modules. To traverse the search space of potential disease modules, we applied a simulated annealing algorithm aimed at maximizing the correlation between module similarity and the gold-standard phenotypic similarity. Importantly, this optimization is employed over hundreds of diseases simultaneously. GLADIATOR's predicted modules highly agree with current knowledge about disease-related proteins. Furthermore, the modules exhibit high coherence with respect to functional annotations and are highly enriched with known curated pathways, outperforming previous methods. Examination of the predicted proteins shared by similar diseases demonstrates the diverse role of these proteins in mediating related processes across similar diseases. Last, we provide a detailed analysis of the suggested molecular mechanism predicted by GLADIATOR for hyperinsulinism, suggesting novel proteins involved in its pathology. GLADIATOR predicts disease modules by integrating knowledge of disease-related proteins and phenotypes across multiple diseases. The predicted modules are functionally coherent and are more in line with current biological knowledge compared to modules obtained using previous disease-centric methods. The source code for GLADIATOR can be downloaded from http://www.cs.tau.ac.il/~roded/GLADIATOR.zip .
Psychosocially influenced cancer: diverse early-life stress experiences and links to breast cancer.
Schuler, Linda A; Auger, Anthony P
2010-11-01
This perspective on Boyd et al. (beginning on page 1398 in this issue of the journal) discusses recent published research examining the interplay between social stress and breast cancer. Cross-disciplinary studies using genetically defined mouse models and established neonatal and peripubertal paradigms of social stress are illuminating biological programming by diverse early-life experiences for the risk of breast cancer. Understanding the mechanisms underlying this programming can lead to the identification of risk factors and sensitive developmental windows, enabling improved prevention and treatment strategies for this devastating disease. ©2010 AACR.
Son, Taeyoon; Kang, Heesung; Jung, Byungjo
2016-05-01
Intense pulsed light (IPL) with low energy insufficient to completely destroy a vasculature was applied to rabbit ears to investigate vasculature alteration. Glycerol was combined with IPL to enhance the transfer efficacy of IPL energy. Both trans-illumination and laser speckle contrast images were obtained and analyzed after treatment. The application of IPL and glycerol combination induced vasodilation and improvement in blood flow. Moreover, such phenomenon was maintained over time. IPL may be applied to treat blood circulatory diseases by inducing vasodilation and to improve blood flow. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
2004-01-01
The WEstinghouse Lighting Corporation's Eye Saver[TM] Easy Reading Light Bulb is the result of collaboration between Westinghouse, Marshall Research LLC, and NASA's Space Optics Manufacturing Technology Center at Marshall Space Flight Center. The light bulb contains a chrome top that directs light to areas where it is needed most. The bulb, which lasts 2,000 hours, provides 40 percent more surface illumination on work and reading surfaces, compared to a standard incandescent bulb. The lightly frosted finish reduces glare, which helps to reduce eyestrain. The bulb is particularly helpful for people with low vision and eye diseases such as macular degeneration.
Pigment dispersion syndrome and pigmentary glaucoma--a major review.
Niyadurupola, Nuwan; Broadway, David C
2008-12-01
Pigment dispersion syndrome (PDS) is an interesting condition that can lead to secondary open angle glaucoma. Pigmentary glaucoma is primarily a disease of young people, myopes and men. PDS is characterized by the presence of Krukenberg spindles, iris trans-illumination defects, trabecular meshwork pigmentation and backward bowing of the iris. Posterior bowing of the iris causes rubbing of the pigmented iris epithelium against lens structures, liberation of pigment and trabecular meshwork changes that result in reduced aqueous outflow with the risk of glaucoma. Peripheral laser iridotomy can reverse backward bowing of the iris and may prevent progression of pigmentary glaucoma.
Peppercorn, Amanda F.; Miller, Melissa B.; Fitzgerald, David; Weber, David J.; Groben, Pamela A.; Cairns, Bruce A.
2015-01-01
The pathogenesis of Stevens Johnson Syndrome (SJS) remains obscure but it has been associated with various infectious agents, including members of the Herpes virus family. We present the first report of high level human herpesvirus-6 (HHV-6) viremia at the onset of SJS suggesting a possible new association. This finding supports the need for further investigation into the possible relationship between HHV-6 and SJS which may illuminate the pathogenesis of SJS and bring us closer to achieving enhanced prevention and treatment of this rare disease. PMID:20182379
ERIC Educational Resources Information Center
van Rensburg, Estelle
2008-01-01
This article outlines an illuminative evaluation study of the work-based module in a vocational qualification in Animal Health offered for the paraveterinary industry by a distance education institution in South Africa. In illuminative evaluation, a programme is studied by qualitative methods to gain an in-depth understanding of its…
ERIC Educational Resources Information Center
Illuminating Engineering Research Inst., New York, NY.
Several of the more familiar Illuminating Engineering Research Institute projects which have been chronicled progressively during the past several years are discussed in this report. Those elaborated on are--(1) visual performance and illumination, (2) roadway visual tasks, (3) color preference studies, (4) glare from large sources, (5) discomfort…
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Uniform test method for the measurement of energy consumption of illuminated exit signs. 431.204 Section 431.204 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION... Procedures § 431.204 Uniform test method for the measurement of energy consumption of illuminated exit signs...
A method of solving tilt illumination for multiple distance phase retrieval
NASA Astrophysics Data System (ADS)
Guo, Cheng; Li, Qiang; Tan, Jiubin; Liu, Shutian; Liu, Zhengjun
2018-07-01
Multiple distance phase retrieval is a technique of using a series of intensity patterns to reconstruct a complex-valued image of object. However, tilt illumination originating from the off-axis displacement of incident light significantly impairs its imaging quality. To eliminate this affection, we use cross-correlation calibration to estimate oblique angle of incident light and a Fourier-based strategy to correct tilted illumination effect. Compared to other methods, binary and biological object are both stably reconstructed in simulation and experiment. This work provides a simple but beneficial method to solve the problem of tilt illumination for lens-free multi-distance system.
Zhang, Haiyan; Vasanthan, Thava; Wettasinghe, Mahinda
2004-12-29
The effect of germination and growth under illuminated and dark environments on canola seed reserves was investigated. Depletion of proteins and lipids in whole seedlings and their top (leaf/cotyledons) and bottom parts (stem/roots/seed coat) was independent of light, whereas the protein solubility increased at a faster rate under an illuminated environment than in the dark. A rapid increase in free fatty acids but a net decrease of dry matter content in seedlings grown in the dark environment was observed. The dry matter content of seedlings grown in the illuminated environment increased due to photosynthetic biomass accumulation.
Sun, Wen-Shing; Tien, Chuen-Lin; Tsuei, Chih-Hsuan; Pan, Jui-Wen
2014-10-10
We simulate and compare the illuminance, uniformity, and efficiency of metal-halide lamps, white LED light sources, and hybrid light box designs combining sunlight and white LED lighting used for indoor basketball court illumination. According to the optical simulation results and our examination of real situations, we find that hybrid light box designs combining sunlight and white LEDs do perform better than either metal-halide lamps or white LED lights. An evaluation of the sunlight concentrator system used in our inverted solar cell shows that the energy consumption of stadium lighting can be reduced significantly.
Mutual Comparative Filtering for Change Detection in Videos with Unstable Illumination Conditions
NASA Astrophysics Data System (ADS)
Sidyakin, Sergey V.; Vishnyakov, Boris V.; Vizilter, Yuri V.; Roslov, Nikolay I.
2016-06-01
In this paper we propose a new approach for change detection and moving objects detection in videos with unstable, abrupt illumination changes. This approach is based on mutual comparative filters and background normalization. We give the definitions of mutual comparative filters and outline their strong advantage for change detection purposes. Presented approach allows us to deal with changing illumination conditions in a simple and efficient way and does not have drawbacks, which exist in models that assume different color transformation laws. The proposed procedure can be used to improve a number of background modelling methods, which are not specifically designed to work under illumination changes.
Three-dimensional wide-field pump-probe structured illumination microscopy
Kim, Yang-Hyo; So, Peter T.C.
2017-01-01
We propose a new structured illumination scheme for achieving depth resolved wide-field pump-probe microscopy with sub-diffraction limit resolution. By acquiring coherent pump-probe images using a set of 3D structured light illumination patterns, a 3D super-resolution pump-probe image can be reconstructed. We derive the theoretical framework to describe the coherent image formation and reconstruction scheme for this structured illumination pump-probe imaging system and carry out numerical simulations to investigate its imaging performance. The results demonstrate a lateral resolution improvement by a factor of three and providing 0.5 µm level axial optical sectioning. PMID:28380860
NASA Astrophysics Data System (ADS)
Hamadeh, H.; Naddaf, M.; Jazmati, A.
2008-12-01
Porous silicon (PS) has been prepared by anodic etching of boron doped silicon under the influence of monochromatic light illumination. The optical properties of the PS samples have been investigated using temperature dependent photoluminescence (PL) spectroscopy. An overall enhancement of the infrared luminescence yield is caused by the light illumination. In the visible spectral range, changes at the low energy side of the broad PL band were observed. In the near infrared spectral range, a new PL band at 850 nm, which is strongly correlated with light illumination, was detected. The new PL band disappears once blue light is used, whereas an increase in its intensity is observed, when the etching is performed under the illumination of light with wavelengths close to the band gap. By increasing the temperature, the 850 nm transition band grows at the expense of the main near infrared transition at 1100 nm. The recombination characteristics of this PL band are indicative of its extrinsic nature. The macroscopic morphology shows strong dependence on the wavelength of the illumination light. Photoassisted preparation could provide a tool for the control of the optical and structural properties of PS.
NASA Astrophysics Data System (ADS)
Li, Shuo; Wang, Hui; Wang, Liyong; Yu, Xiangzhou; Yang, Le
2018-01-01
The uneven illumination phenomenon reduces the quality of remote sensing image and causes interference in the subsequent processing and applications. A variational method based on Retinex with double-norm hybrid constraints for uneven illumination correction is proposed. The L1 norm and the L2 norm are adopted to constrain the textures and details of reflectance image and the smoothness of the illumination image, respectively. The problem of separating the illumination image from the reflectance image is transformed into the optimal solution of the variational model. In order to accelerate the solution, the split Bregman method is used to decompose the variational model into three subproblems, which are calculated by alternate iteration. Two groups of experiments are implemented on two synthetic images and three real remote sensing images. Compared with the variational Retinex method with single-norm constraint and the Mask method, the proposed method performs better in both visual evaluation and quantitative measurements. The proposed method can effectively eliminate the uneven illumination while maintaining the textures and details of the remote sensing image. Moreover, the proposed method using split Bregman method is more than 10 times faster than the method with the steepest descent method.
Shaping plasmon beams via the controlled illumination of finite-size plasmonic crystals
Bouillard, J.-S.; Segovia, P.; Dickson, W.; Wurtz, G. A.; Zayats, A. V.
2014-01-01
Plasmonic crystals provide many passive and active optical functionalities, including enhanced sensing, optical nonlinearities, light extraction from LEDs and coupling to and from subwavelength waveguides. Here we study, both experimentally and numerically, the coherent control of SPP beam excitation in finite size plasmonic crystals under focussed illumination. The correct combination of the illuminating spot size, its position relative to the plasmonic crystal, wavelength and polarisation enables the efficient shaping and directionality of SPP beam launching. We show that under strongly focussed illumination, the illuminated part of the crystal acts as an antenna, launching surface plasmon waves which are subsequently filtered by the surrounding periodic lattice. Changing the illumination conditions provides rich opportunities to engineer the SPP emission pattern. This offers an alternative technique to actively modulate and control plasmonic signals, either via micro- and nano-electromechanical switches or with electro- and all-optical beam steering which have direct implications for the development of new integrated nanophotonic devices, such as plasmonic couplers and switches and on-chip signal demultiplexing. This approach can be generalised to all kinds of surface waves, either for the coupling and discrimination of light in planar dielectric waveguides or the generation and control of non-diffractive SPP beams. PMID:25429786
Depth Structure from Asymmetric Shading Supports Face Discrimination
Chen, Chien-Chung; Chen, Chin-Mei; Tyler, Christopher W.
2013-01-01
To examine the effect of illumination direction on the ability of observers to discriminate between faces, we manipulated the direction of illumination on scanned 3D face models. In order to dissociate the surface reflectance and illumination components of front-view face images, we introduce a symmetry algorithm that can separate the symmetric and asymmetric components of the face in both low and high spatial frequency bands. Based on this approach, hybrid faces stimuli were constructed with different combinations of symmetric and asymmetric spatial content. Discrimination results with these images showed that asymmetric illumination information biased face perception toward the structure of the shading component, while the symmetric illumination information had little, if any, effect. Measures of perceived depth showed that this property increased systematically with the asymmetric but not the symmetric low spatial frequency component. Together, these results suggest that (1) the asymmetric 3D shading information dramatically affects both the perceived facial information and the perceived depth of the facial structure; and (2) these effects both increase as the illumination direction is shifted to the side. Thus, our results support the hypothesis that face processing has a strong 3D component. PMID:23457484
Color rendering indices in global illumination methods
NASA Astrophysics Data System (ADS)
Geisler-Moroder, David; Dür, Arne
2009-02-01
Human perception of material colors depends heavily on the nature of the light sources used for illumination. One and the same object can cause highly different color impressions when lit by a vapor lamp or by daylight, respectively. Based on state-of-the-art colorimetric methods we present a modern approach for calculating color rendering indices (CRI), which were defined by the International Commission on Illumination (CIE) to characterize color reproduction properties of illuminants. We update the standard CIE method in three main points: firstly, we use the CIELAB color space, secondly, we apply a Bradford transformation for chromatic adaptation, and finally, we evaluate color differences using the CIEDE2000 total color difference formula. Moreover, within a real-world scene, light incident on a measurement surface is composed of a direct and an indirect part. Neumann and Schanda1 have shown for the cube model that interreflections can influence the CRI of an illuminant. We analyze how color rendering indices vary in a real-world scene with mixed direct and indirect illumination and recommend the usage of a spectral rendering engine instead of an RGB based renderer for reasons of accuracy of CRI calculations.
PET and NIR Optical Imaging Using Self-Illuminating 64Cu-Doped Chelator-Free Gold Nanoclusters
Hu, Hao; Huang, Peng; Weiss, Orit Jacobson; Yan, Xuefeng; Yue, Xuyi; Zhang, Molly Gu; Tang, Yuxia; Nie, Liming; Ma, Ying; Niu, Gang; Wu, Kaichun; Chen, Xiaoyuan
2014-01-01
Self-illuminating fluorescence imaging without autofluorescence background interference has recently aroused more research interests in molecular imaging. Currently, only a few self-illuminating probes were developed, based mainly on toxic quantum dots such as CdSe, CdTe. Herein, we report a novel design of nontoxic self-illuminating gold nanocluster (64Cu-doped AuNCs) for dual-modality positron emission tomography (PET) and near-infrared (NIR) fluorescence imaging based on Cerenkov resonance energy transfer (CRET). PET radionuclide 64Cu was introduced by a chelator-free doping method, which played dual roles as the energy donor and the PET imaging source. Meanwhile, AuNCs acted as the energy acceptor for NIR fluorescence imaging. 64Cu-doped AuNCs exhibited efficient CRET-NIR and PET imaging both in vitro and in vivo. In a U87MG glioblastoma xenograft model, 64Cu-doped AuNCs showed high tumor uptake (14.9%ID/g at 18 h) and produced satisfactory tumor self-illuminating NIR images in the absence of external excitation. This self-illuminating nanocluster with non-toxicity and good biocompatibility can be employed as a novel imaging contrast agent for biomedical applications, especially for molecular imaging. PMID:25224367
PET and NIR optical imaging using self-illuminating (64)Cu-doped chelator-free gold nanoclusters.
Hu, Hao; Huang, Peng; Weiss, Orit Jacobson; Yan, Xuefeng; Yue, Xuyi; Zhang, Molly Gu; Tang, Yuxia; Nie, Liming; Ma, Ying; Niu, Gang; Wu, Kaichun; Chen, Xiaoyuan
2014-12-01
Self-illuminating fluorescence imaging without autofluorescence background interference has recently aroused more research interests in molecular imaging. Currently, only a few self-illuminating probes were developed, based mainly on toxic quantum dots such as CdSe, CdTe. Herein, we report a novel design of nontoxic self-illuminating gold nanocluster ((64)Cu-doped AuNCs) for dual-modality positron emission tomography (PET) and near-infrared (NIR) fluorescence imaging based on Cerenkov resonance energy transfer (CRET). PET radionuclide (64)Cu was introduced by a chelator-free doping method, which played dual roles as the energy donor and the PET imaging source. Meanwhile, AuNCs acted as the energy acceptor for NIR fluorescence imaging. (64)Cu-doped AuNCs exhibited efficient CRET-NIR and PET imaging both in vitro and in vivo. In a U87MG glioblastoma xenograft model, (64)Cu-doped AuNCs showed high tumor uptake (14.9 %ID/g at 18 h) and produced satisfactory tumor self-illuminating NIR images in the absence of external excitation. This self-illuminating nanocluster with non-toxicity and good biocompatibility can be employed as a novel imaging contrast agent for biomedical applications, especially for molecular imaging. Published by Elsevier Ltd.
Complementary aspects of spatial resolution and signal-to-noise ratio in computational imaging
NASA Astrophysics Data System (ADS)
Gureyev, T. E.; Paganin, D. M.; Kozlov, A.; Nesterets, Ya. I.; Quiney, H. M.
2018-05-01
A generic computational imaging setup is considered which assumes sequential illumination of a semitransparent object by an arbitrary set of structured coherent illumination patterns. For each incident illumination pattern, all transmitted light is collected by a photon-counting bucket (single-pixel) detector. The transmission coefficients measured in this way are then used to reconstruct the spatial distribution of the object's projected transmission. It is demonstrated that the square of the spatial resolution of such a setup is usually equal to the ratio of the image area to the number of linearly independent illumination patterns. If the noise in the measured transmission coefficients is dominated by photon shot noise, then the ratio of the square of the mean signal to the noise variance is proportional to the ratio of the mean number of registered photons to the number of illumination patterns. The signal-to-noise ratio in a reconstructed transmission distribution is always lower if the illumination patterns are nonorthogonal, because of spatial correlations in the measured data. Examples of imaging methods relevant to the presented analysis include conventional imaging with a pixelated detector, computational ghost imaging, compressive sensing, super-resolution imaging, and computed tomography.
Spectrally enhanced image resolution of tooth enamel surfaces
NASA Astrophysics Data System (ADS)
Zhang, Liang; Nelson, Leonard Y.; Berg, Joel H.; Seibel, Eric J.
2012-01-01
Short-wavelength 405 nm laser illumination of surface dental enamel using an ultrathin scanning fiber endoscope (SFE) produced enhanced detail of dental topography. The surfaces of human extracted teeth and artificial erosions were imaged with 405 nm, 444 nm, 532 nm, or 635 nm illumination lasers. The obtained images were then processed offline to compensate for any differences in the illumination beam diameters between the different lasers. Scattering and absorption coefficients for a Monte Carlo model of light propagation in dental enamel for 405 nm were scaled from published data at 532 nm and 633 nm. The value of the scattering coefficient used in the model was scaled from the coefficients at 532 nm and 633 nm by the inverse third power of wavelength. Simulations showed that the penetration depth of short-wavelength illumination is localized close to the enamel surface, while long-wavelength illumination travels much further and is backscattered from greater depths. Therefore, images obtained using short wavelength laser are not contaminated by the superposition of light reflected from enamel tissue at greater depths. Hence, the SFE with short-wavelength illumination may make it possible to visualize surface manifestations of phenomena such as demineralization, thus better aiding the clinician in the detection of early caries.
Laser exposure incidents: pilot ocular health and aviation safety issues.
Nakagawara, Van B; Wood, Kathryn J; Montgomery, Ron W
2008-09-01
A database of aviation reports involving laser illumination of flight crewmembers has been established and maintained at the Civil Aerospace Medical Institute. A review of recent laser illumination reports was initiated to investigate the significance of these events. Reports that involved laser exposures of civilian aircraft in the United States were analyzed for the 13-month period (January 1, 2004, through January 31, 2005). There were 90 reported instances of laser illumination during the study period. A total of 53 reports involved laser exposure of commercial aircraft. Lasers illuminated the cockpit in 41 (46%) of the incidents. Of those, 13 (32%) incidents resulted in a visual impairment or distraction to a pilot, including 1 incident that reportedly resulted in an ocular injury. Nearly 96% of these reports occurred in the last 3 months of the study period. There were no aviation accidents in which laser light illumination was found to be a contributing factor. Operational problems have resulted from laser illumination incidents in the national airspace system. Eye care practitioners, to provide effective consultations to their pilot patients, should be familiar with the problems that can occur with laser exposure.
Changing lamp type and position to improve lighting quality
NASA Astrophysics Data System (ADS)
Anizar; Syahputri, K.; Sari, RM; Rizkya, I.; Hardianti, DA
2018-03-01
This study investigates the lighting quality on the production floor in a cigarette paper industry by measuring illumination level and luminance. Cigarette paper inspection is performed manually by operators, and the criteria of defects are the cigarette paper has a hole, is rough and dirty. Operators complain that the room is pretty dark, which makes them unable to see clearly the cigarette paper defect. The government of Indonesia Health Ministerial Decree No 1405 The Year 2002 states that illumination level for continuous manual labor is 200 lux. Illumination level is measured for four days at 08.00, 10.00, 12.30, and 14.00 o’clock with 4 in 1 environmental meter. From the measurement result, it is found that using 7 LED lamps of 60 Watts can produce average illumination level of 70 lux. Low illuminance is caused by illumination level that does not meet the need 0f 569.759 lumen. Alternatives that can be used to increase lumen number are changing lamp type and position. One of the possibilities is using 24 LED of 138 Watts set 5.7 meters apart from one another can meet this demand. Another is using 5 LED of 150 Watts installed above the field of work.
Effects of illumination on image reconstruction via Fourier ptychography
NASA Astrophysics Data System (ADS)
Cao, Xinrui; Sinzinger, Stefan
2017-12-01
The Fourier ptychographic microscopy (FPM) technique provides high-resolution images by combining a traditional imaging system, e.g. a microscope or a 4f-imaging system, with a multiplexing illumination system, e.g. an LED array and numerical image processing for enhanced image reconstruction. In order to numerically combine images that are captured under varying illumination angles, an iterative phase-retrieval algorithm is often applied. However, in practice, the performance of the FPM algorithm degrades due to the imperfections of the optical system, the image noise caused by the camera, etc. To eliminate the influence of the aberrations of the imaging system, an embedded pupil function recovery (EPRY)-FPM algorithm has been proposed [Opt. Express 22, 4960-4972 (2014)]. In this paper, we study how the performance of FPM and EPRY-FPM algorithms are affected by imperfections of the illumination system using both numerical simulations and experiments. The investigated imperfections include varying and non-uniform intensities, and wavefront aberrations. Our study shows that the aberrations of the illumination system significantly affect the performance of both FPM and EPRY-FPM algorithms. Hence, in practice, aberrations in the illumination system gain significant influence on the resulting image quality.
Violet LED light enhances the recruitment of a thrip predator in open fields.
Ogino, Takumi; Uehara, Takuya; Muraji, Masahiko; Yamaguchi, Terumi; Ichihashi, Takahisa; Suzuki, Takahiro; Kainoh, Yooichi; Shimoda, Masami
2016-09-08
The predatory bug Orius sauteri is an indigenous natural enemy of thrips and whiteflies in Asian countries. To put these bugs to practical use in pest management, methods to attract and retain the bugs in agricultural fields are needed. We previously showed that violet light (405 nm) attracts O. sauteri selectively. Many thrips and whiteflies are attracted to UV or green light. In this study, we examined the effect of violet-LED illumination on O. sauteri in pesticide-free eggplant (Solanum melongena L.) cultivation. In three cultivation trials, the density of O. sauteri on eggplant leaves was consistently higher in the illuminated plots; at least twice that of the non-illuminated plots. Simultaneously, the density of thrips declined markedly to less than half that of the non-illuminated plots. We identified three positive effects of violet light including an "immediate-effect" on predator attraction, a "persistent-effect" on predator reproduction, and a "secondary-effect" on the food web structure. Our results showed that illumination with violet light provides a powerful tool for integrated pest management. This is the first report on the use of illumination to manipulate the behavior of natural enemies.
Violet LED light enhances the recruitment of a thrip predator in open fields
Ogino, Takumi; Uehara, Takuya; Muraji, Masahiko; Yamaguchi, Terumi; Ichihashi, Takahisa; Suzuki, Takahiro; Kainoh, Yooichi; Shimoda, Masami
2016-01-01
The predatory bug Orius sauteri is an indigenous natural enemy of thrips and whiteflies in Asian countries. To put these bugs to practical use in pest management, methods to attract and retain the bugs in agricultural fields are needed. We previously showed that violet light (405 nm) attracts O. sauteri selectively. Many thrips and whiteflies are attracted to UV or green light. In this study, we examined the effect of violet-LED illumination on O. sauteri in pesticide-free eggplant (Solanum melongena L.) cultivation. In three cultivation trials, the density of O. sauteri on eggplant leaves was consistently higher in the illuminated plots; at least twice that of the non-illuminated plots. Simultaneously, the density of thrips declined markedly to less than half that of the non-illuminated plots. We identified three positive effects of violet light including an “immediate-effect” on predator attraction, a “persistent-effect” on predator reproduction, and a “secondary-effect” on the food web structure. Our results showed that illumination with violet light provides a powerful tool for integrated pest management. This is the first report on the use of illumination to manipulate the behavior of natural enemies. PMID:27604315
Wide-area SWIR arrays and active illuminators
NASA Astrophysics Data System (ADS)
MacDougal, Michael; Hood, Andrew; Geske, Jon; Wang, Chad; Renner, Daniel; Follman, David; Heu, Paula
2012-01-01
We describe the factors that go into the component choices for a short wavelength (SWIR) imager, which include the SWIR sensor, the lens, and the illuminator. We have shown the factors for reducing dark current, and shown that we can achieve well below 1.5 nA/cm2 for 15 μm devices at 7°C. We have mated our InGaAs detector arrays to 640x512 readout integrated integrated circuits (ROICs) to make focal plane arrays (FPAs). In addition, we have fabricated high definition 1920x1080 FPAs for wide field of view imaging. The resulting FPAs are capable of imaging photon fluxes with wavelengths between 1 and 1.6 microns at low light levels. The dark current associated with these FPAs is extremely low, exhibiting a mean dark current density of 0.26 nA/cm2 at 0°C. FLIR has also developed a high definition, 1920x1080, 15 um pitch SWIR sensor. In addition, FLIR has developed laser arrays that provide flat illumination in scenes that are normally light-starved. The illuminators have 40% wall-plug efficiency and provide low-speckle illumination, provide artifact-free imagery versus conventional laser illuminators.
NASA Astrophysics Data System (ADS)
Macdougal, Michael; Geske, Jon; Wang, Chad; Follman, David
2011-06-01
We describe the factors that go into the component choices for a short wavelength IR (SWIR) imager, which include the SWIR sensor, the lens, and the illuminator. We have shown the factors for reducing dark current, and shown that we can achieve well below 1.5 nA/cm2 for 15 μm devices at 7 °C. In addition, we have mated our InGaAs detector arrays to 640×512 readout integrated integrated circuits to make focal plane arrays (FPAs). The resulting FPAs are capable of imaging photon fluxes with wavelengths between 1 and 1.6 μm at low light levels. The dark current associated with these FPAs is extremely low, exhibiting a mean dark current density of 0.26 nA/cm2 at 0 °C. Noise due to the readout can be reduced from 95 to 57 electrons by using off-chip correlated double sampling. In addition, Aerius has developed laser arrays that provide flat illumination in scenes that are normally light-starved. The illuminators have 40% wall-plug efficiency and provide low-speckle illumination, and provide artifact-free imagery versus conventional laser illuminators.
Color and illuminance level of lighting can modulate willingness to eat bell peppers.
Hasenbeck, Aimee; Cho, Sungeun; Meullenet, Jean-François; Tokar, Tonya; Yang, Famous; Huddleston, Elizabeth A; Seo, Han-Seok
2014-08-01
Food products are often encountered under colored lighting, particularly in restaurants and retail stores. However, relatively little attention has been paid to whether the color of ambient lighting can affect consumers' motivation for consumption. This study aimed to determine whether color (Experiment 1) and illuminance level (Experiment 2) of lighting can influence consumers' liking of appearance and their willingness to eat bell peppers. For red, green, and yellow bell peppers, yellow and blue lighting conditions consistently increased participants' liking of appearance the most and the least, respectively. Participants' willingness to consume bell peppers increased the most under yellow lighting and the least under blue lighting. In addition, a dark condition (i.e. low level of lighting illuminance) decreased liking of appearance and willingness to eat the bell peppers compared to a bright condition (i.e. high level of lighting illuminance). Our findings demonstrate that lighting color and illuminance level can influence consumers' hedonic impression and likelihood to consume bell peppers. Furthermore, the influences of color and illuminance level of lighting appear to be dependent on the surface color of bell peppers. © 2013 Society of Chemical Industry.
Illumination discrimination in the absence of a fixed surface-reflectance layout
Radonjić, Ana; Ding, Xiaomao; Krieger, Avery; Aston, Stacey; Hurlbert, Anya C.; Brainard, David H.
2018-01-01
Previous studies have shown that humans can discriminate spectral changes in illumination and that this sensitivity depends both on the chromatic direction of the illumination change and on the ensemble of surfaces in the scene. These studies, however, always used stimulus scenes with a fixed surface-reflectance layout. Here we compared illumination discrimination for scenes in which the surface reflectance layout remains fixed (fixed-surfaces condition) to those in which surface reflectances were shuffled randomly across scenes, but with the mean scene reflectance held approximately constant (shuffled-surfaces condition). Illumination discrimination thresholds in the fixed-surfaces condition were commensurate with previous reports. Thresholds in the shuffled-surfaces condition, however, were considerably elevated. Nonetheless, performance in the shuffled-surfaces condition exceeded that attainable through random guessing. Analysis of eye fixations revealed that in the fixed-surfaces condition, low illumination discrimination thresholds (across observers) were predicted by low overall fixation spread and high consistency of fixation location and fixated surface reflectances across trial intervals. Performance in the shuffled-surfaces condition was not systematically related to any of the eye-fixation characteristics we examined for that condition, but was correlated with performance in the fixed-surfaces condition. PMID:29904786
Intraperitoneal photodynamic therapy of the rat CC531 adenocarcinoma.
Veenhuizen, R. B.; Marijnissen, J. P.; Kenemans, P.; Ruevekamp-Helmers, M. C.; 't Mannetje, L. W.; Helmerhorst, T. J.; Stewart, F. A.
1996-01-01
The goal of this study was to investigate the efficacy of photodynamic therapy (PDT) of a single tumour growing intraperitoneally. For this purpose the CC531 colon carcinoma, implanted in an intraperitoneal fat pad of Wag/RijA rats, was treated with intraperitoneal photodynamic therapy (IPPDT) using Photofrin as the photosensitiser. Two illumination techniques have been compared. An invasive illumination technique using Perspex blocks to illuminate 30 cm2 of the lower abdomen gave a significant delay in tumour growth with 25 J cm-2 applied 1 day after Photofrin. A minimally invasive illumination technique using a balloon catheter to illuminate 14 cm2 resulted in an equivalent growth delay with 75 J cm-2. The route of administration of the photosensitiser did not influence regrowth times of the tumour. Mitomycin C (MMC), a bioreductive agent, was used to exploit the known PDT-induced hypoxia. The combination of IPPDT with MMC resulted in an increased tumoricidal effect. In conclusion, IPPDT led to a significant growth delay for a single tumour implanted intraperitoneally and repetition of the PDT treatment was possible using a minimally invasive illumination technique. Repeated treatments resulted in increased tumour response. PMID:8645584
Physiological responses to illuminance and color temperature of lighting.
Kobayashi, H; Sato, M
1992-01-01
The present study was designed to examine the effects of illuminance and color temperature of room lighting. Four male students volunteered as subjects. Each of them performed a calculation task for 95 minutes under nine different lighting environments consisting of a combination of three levels of illuminance (320lx, 1000lx and 2000lx) and three levels of color temperature (3000 degrees K, 5000 degrees K and 7500 degrees K). Three types of fluorescent lamps were used as a light source to vary the color temperature. Blood pressure, critical flicker frequency (CFF) and accommodation time of eye movements were measured every 30 minutes during the task. The accommodation time was significantly influenced by the illuminance level and both the relaxation time and contraction time were prolonged under 2000lx. The diastolic blood pressure was significantly affected by the color temperature level and increased under 7500 degrees K. As for the CFF, the interaction between illuminance and color temperature was significant. These results mean that not only the illuminance but also color temperature produces physiological effects. The present study may be the first to recognize the effect of color temperature on the blood pressure.
Up-converted ultraviolet luminescence of Er3+:BaGd2ZnO5 phosphors for healthy illumination
NASA Astrophysics Data System (ADS)
Zhang, Ya; Cui, Qingzhi; Wang, Zhanyong; Liu, Gan; Tian, Tian; Xu, Jiayue
2016-09-01
Moderate level of exposure to the solar irradiation containing UV component is essential for health care. To incorporate the UV-emitting phosphors into the commercial YAG-based white light-emitting diode introduces the possibilities of healthy illumination to individuals' daily lives. 1 mol.% Er3+-doped BaGd2ZnO5 (BGZ) particles were synthesized via sol-gel method and efficient up-converted luminescence peaked at 380 nm was detected under 480 nm excitation. The mixed phosphors with varied mass ratio of Er3+:BGZ and Ce3+:YAG particles were encapsulated to form LEDs. The study of the LEDs indicated that the introduction of BGZ component favored the enhancement of color-rendering index and the neutralization of the white light emitting. The WLED with the BGZ/YAG ratio of 8:2 was recommendable for its excellent overall white light luminous performances and UV intensity of 84.55 mW/cm2. The UV illumination dose of the WLEDs with mixed YAG and BGZ was controllable by adjusting the ratio, the illumination distance and the illumination time. Er3+:BGZ phosphors are promising UVemitting phosphors for healthy indoor illumination.
Characterization of Lunar Polar Illumination from a Power System Perspective
NASA Technical Reports Server (NTRS)
Fincannon, James
2008-01-01
This paper presents the results of illumination analyses for the lunar south and north pole regions obtained using an independently developed analytical tool and two types of digital elevation models (DEM). One DEM was based on radar height data from Earth observations of the lunar surface and the other was a combination of the radar data with a separate dataset generated using Clementine spacecraft stereo imagery. The analysis tool enables the assessment of illumination at most locations in the lunar polar regions for any time and any year. Maps are presented for both lunar poles for the worst case winter period (the critical power system design and planning bottleneck) and for the more favorable best case summer period. Average illumination maps are presented to help understand general topographic trends over the regions. Energy storage duration maps are presented to assist in power system design. Average illumination fraction, energy storage duration, solar/horizon terrain elevation profiles and illumination fraction profiles are presented for favorable lunar north and south pole sites which have the potential for manned or unmanned spacecraft operations. The format of the data is oriented for use by power system designers to develop mass optimized solar and energy storage systems.
Rasta, Seyed Hossein; Partovi, Mahsa Eisazadeh; Seyedarabi, Hadi; Javadzadeh, Alireza
2015-01-01
To investigate the effect of preprocessing techniques including contrast enhancement and illumination correction on retinal image quality, a comparative study was carried out. We studied and implemented a few illumination correction and contrast enhancement techniques on color retinal images to find out the best technique for optimum image enhancement. To compare and choose the best illumination correction technique we analyzed the corrected red and green components of color retinal images statistically and visually. The two contrast enhancement techniques were analyzed using a vessel segmentation algorithm by calculating the sensitivity and specificity. The statistical evaluation of the illumination correction techniques were carried out by calculating the coefficients of variation. The dividing method using the median filter to estimate background illumination showed the lowest Coefficients of variations in the red component. The quotient and homomorphic filtering methods after the dividing method presented good results based on their low Coefficients of variations. The contrast limited adaptive histogram equalization increased the sensitivity of the vessel segmentation algorithm up to 5% in the same amount of accuracy. The contrast limited adaptive histogram equalization technique has a higher sensitivity than the polynomial transformation operator as a contrast enhancement technique for vessel segmentation. Three techniques including the dividing method using the median filter to estimate background, quotient based and homomorphic filtering were found as the effective illumination correction techniques based on a statistical evaluation. Applying the local contrast enhancement technique, such as CLAHE, for fundus images presented good potentials in enhancing the vasculature segmentation.
Using color histogram normalization for recovering chromatic illumination-changed images.
Pei, S C; Tseng, C L; Wu, C C
2001-11-01
We propose a novel image-recovery method using the covariance matrix of the red-green-blue (R-G-B) color histogram and tensor theories. The image-recovery method is called the color histogram normalization algorithm. It is known that the color histograms of an image taken under varied illuminations are related by a general affine transformation of the R-G-B coordinates when the illumination is changed. We propose a simplified affine model for application with illumination variation. This simplified affine model considers the effects of only three basic forms of distortion: translation, scaling, and rotation. According to this principle, we can estimate the affine transformation matrix necessary to recover images whose color distributions are varied as a result of illumination changes. We compare the normalized color histogram of the standard image with that of the tested image. By performing some operations of simple linear algebra, we can estimate the matrix of the affine transformation between two images under different illuminations. To demonstrate the performance of the proposed algorithm, we divide the experiments into two parts: computer-simulated images and real images corresponding to illumination changes. Simulation results show that the proposed algorithm is effective for both types of images. We also explain the noise-sensitive skew-rotation estimation that exists in the general affine model and demonstrate that the proposed simplified affine model without the use of skew rotation is better than the general affine model for such applications.
Ambient light-based optical biosensing platform with smartphone-embedded illumination sensor.
Park, Yoo Min; Han, Yong Duk; Chun, Hyeong Jin; Yoon, Hyun C
2017-07-15
We present a hand-held optical biosensing system utilizing a smartphone-embedded illumination sensor that is integrated with immunoblotting assay method. The smartphone-embedded illumination sensor is regarded as an alternative optical receiver that can replaces the conventional optical analysis apparatus because the illumination sensor can respond to the ambient light in a wide range of wavelengths, including visible and infrared. To demonstrate the biosensing applicability of our system employing the enzyme-mediated immunoblotting and accompanying light interference, various types of ambient light conditions including outdoor sunlight and indoor fluorescent were tested. For the immunoblotting assay, the biosensing channel generating insoluble precipitates as an end product of the enzymatic reaction is fabricated and mounted on the illumination sensor of the smartphone. The intensity of penetrating light arrives on the illumination sensor is inversely proportional to the amount of precipitates produced in the channel, and these changes are immediately analyzed and quantified via smartphone software. In this study, urinary C-terminal telopeptide fragment of type II collagen (uCTX-II), a biomarker of osteoarthritis diagnosis, was tested as a model analyte. The developed smartphone-based sensing system efficiently measured uCTX-II in the 0-5ng/mL concentration range with a high sensitivity and accuracy under various light conditions. These assay results show that the illumination sensor-based optical biosensor is suitable for point-of-care testing (POCT). Copyright © 2016 Elsevier B.V. All rights reserved.
Mao, Xianglong; Li, Hongtao; Han, Yanjun; Luo, Yi
2014-10-20
Designing an illumination system for a surface light source with a strict compactness requirement is quite challenging, especially for the general three-dimensional (3D) case. In accordance with the two key features of an expected illumination distribution, i.e., a well-controlled boundary and a precise illumination pattern, a two-step design method is proposed in this paper for highly compact 3D freeform illumination systems. In the first step, a target shape scaling strategy is combined with an iterative feedback modification algorithm to generate an optimized freeform optical system with a well-controlled boundary of the target distribution. In the second step, a set of selected radii of the system obtained in the first step are optimized to further improve the illuminating quality within the target region. The method is quite flexible and effective to design highly compact optical systems with almost no restriction on the shape of the desired target field. As examples, three highly compact freeform lenses with ratio of center height h of the lens and the maximum dimension D of the source ≤ 2.5:1 are designed for LED surface light sources to form a uniform illumination distribution on a rectangular, a cross-shaped and a complex cross pierced target plane respectively. High light control efficiency of η > 0.7 as well as low relative standard illumination deviation of RSD < 0.07 is obtained simultaneously for all the three design examples.
Advanced illumination control algorithm for medical endoscopy applications
NASA Astrophysics Data System (ADS)
Sousa, Ricardo M.; Wäny, Martin; Santos, Pedro; Morgado-Dias, F.
2015-05-01
CMOS image sensor manufacturer, AWAIBA, is providing the world's smallest digital camera modules to the world market for minimally invasive surgery and one time use endoscopic equipment. Based on the world's smallest digital camera head and the evaluation board provided to it, the aim of this paper is to demonstrate an advanced fast response dynamic control algorithm of the illumination LED source coupled to the camera head, over the LED drivers embedded on the evaluation board. Cost efficient and small size endoscopic camera modules nowadays embed minimal size image sensors capable of not only adjusting gain and exposure time but also LED illumination with adjustable illumination power. The LED illumination power has to be dynamically adjusted while navigating the endoscope over changing illumination conditions of several orders of magnitude within fractions of the second to guarantee a smooth viewing experience. The algorithm is centered on the pixel analysis of selected ROIs enabling it to dynamically adjust the illumination intensity based on the measured pixel saturation level. The control core was developed in VHDL and tested in a laboratory environment over changing light conditions. The obtained results show that it is capable of achieving correction speeds under 1 s while maintaining a static error below 3% relative to the total number of pixels on the image. The result of this work will allow the integration of millimeter sized high brightness LED sources on minimal form factor cameras enabling its use in endoscopic surgical robotic or micro invasive surgery.
Vimalanathan, Komalanathan; Ramesh Babu, Thangavelu
2014-01-01
The effect of indoor environment may have an influence on the performance, productivity health and well-being of office workers. Environmental factors such as indoor temperature and illumination have been investigated at three levels. A neurobehavioral test (NBT) has been proposed for the evaluation of office workersc performance. A field lab to emulate an office has been created. In controlled condition of environmental factors, the neurobehavioral test was conducted. The response time and the number of errors in each test have been recorded. A randomized block factorial design was used to analyze the responses of office worker's performance. The results revealed that the independent and interaction effect of temperature and illumination have significant effect on the office workers' performance. The effect of indoor room temperature has more influences than the effect of illumination. The effect of indoor temperature has 38.56% of contribution on the performance. The optimum levels of indoor temperature at 21°C and illumination at 1000 lux have improved the work performance and health of office workers. The indoor room temperature and illumination are more influence on the performance of the office workers. It may be concluded that the impact of indoor room temperature (38.56%) is more on the office worker's performance than the effect of illumination (19.91%). Further, it may be concluded that the optimum level of indoor room temperature (21°C) and illumination (1000lux) have improved the work performance, health and productivity of office workers.
Ito, Yuhei; Suzuki, Kyouichi; Ichikawa, Tsuyoshi; Watanabe, Yoichi; Sato, Taku; Sakuma, Jun; Saito, Kiyoshi
2018-06-12
Laser surgical microscopes should enable uniform illumination of the operative field, and require less luminous energy compared with existing xenon surgical microscopes. To examine the utility of laser illumination in fluorescence cerebral angiography. Fluorescein sodium (fluorescein) was used as a fluorescent dye. We first compared the clarity of cerebral blood flow images collected by fluorescence angiography between the laser illumination and xenon illumination methods. We then assessed use of the laser illuminator for simultaneous observation of blood flow and surrounding structures during fluorescence angiography. Furthermore, the study was designed to evaluate usefulness of the thus determined excitation light in clinical cases. Fluorescence angiography using blue light laser for excitation provided higher clarity and contrast blood flow images compared with using blue light generated from a xenon lamp. Further, illumination with excitation light consisting of a combination of 3 types of laser (higher level of blue light, no green light, and lower level of red light) enabled both blood flow and surrounding structures to be observed through the microscope directly by the surgeon. Laser-illuminated fluorescence angiography provides high clarity and contrast images of cerebral blood flow. Further, a laser providing strong blue light and weak red light for excitation light enables simultaneous visual observation of fluorescent blood flow and surrounding structures by the surgeon using a surgical microscope. Overall, these data suggest that laser surgical microscopes are useful for both ordinary operative manipulations and fluorescence angiography.
ERIC Educational Resources Information Center
Çaliskan, Ilke
2014-01-01
The aim of this study was to identify the needs of third grade classroom teaching students about science teaching course in terms of Parlett's Illuminative program evaluation model. Phenomographic research design was used in this study. Illuminative program evaluation model was chosen for this study in terms of its eclectic and process-based…
ERIC Educational Resources Information Center
Çaliskan, Ilke
2014-01-01
The aim of this study was to identify the needs of third grade classroom teaching students about science teaching course in terms of Parlett's Illuminative program evaluation model. Phenomographic research design was used in this study. Illuminative program evaluation model was chosen for this study in terms of its eclectic and process-based…
Asher, A; Shabtay, A; Brosh, A; Eitam, H; Agmon, R; Cohen-Zinder, M; Zubidat, A E; Haim, A
2015-01-01
Pineal melatonin (MLT) is produced at highest levels during the night, under dark conditions. We evaluated differences in MLT-concentration by comparing daytime versus night time milk samples, from two dairy farms with different night illumination conditions: (1) natural dark (Dark-Night); (2) short wavelength Artificial Light at Night (ALAN, Night-Illuminated). Samples were collected from 14 Israeli Holstein cows from each commercial dairy farm at 04:30 h ("Night-milk") 12:30 h ("Day-milk") and analyzed for MLT-concentration. In order to study the effects of night illumination conditions on cows circadian rhythms, Heart Rate (HR) daily rhythms were recorded. MLT-concentrations of Night-milk samples from the dark-night group were significantly (p < 0.001) higher than those of Night-illuminated conditions (30.70 ± 1.79 and 17.81 ± 0.33 pg/ml, respectively). Interestingly, night illumination conditions also affected melatonin concentrations at daytime where under Dark-Night conditions values are significantly (p < 0.001) higher than Night-Illuminated conditions, (5.36 ± 0.33 and 3.30 ± 0.18 pg/ml, respectively). There were no significant differences between the two treatments in the milk yield and milk composition except somatic cell count (SCC), which was significantly lower (p = 0.02) in the Dark-Night group compared with the Night-Illuminated group. Cows in both groups presented a significant (p < 0.01) HR daily rhythm, therefore we assume that in the night illuminated cows feeding and milking time are the "time keeper", while in the Dark-night cows, HR rhythms were entrained by the light/dark cycle. The higher MLT-concentration in Dark-night cows with the lower SCC values calls upon farmers to avoid exposure of cows to ALAN. Therefore, under Dark-night conditions milk quality will improve by lowering SCC values where separation between night and day of such milk can produce chrono-functional milk, naturally rich with MLT.
Ghate, Vinayak S; Ng, Kheng Siang; Zhou, Weibiao; Yang, Hyunsoo; Khoo, Gek Hoon; Yoon, Won-Byong; Yuk, Hyun-Gyun
2013-09-16
The antibacterial effect of light emitting diodes (LEDs) in the visible region (461, 521 and 642 nm) of the electromagnetic spectrum was investigated on Escherichia coli O157:H7, Salmonella typhimurium, Listeria monocytogenes and Staphylococcus aureus. The irradiances of the 461, 521 and 642 nm LEDs were 22.1, 16 and 25.4 mW/cm², respectively. Bacterial cultures suspended in tryptic soy broth were illuminated by 10-watt LEDs at a distance of 4.5 cm for 7.5h at 20, 15 and 10 °C. Regardless of the bacterial strains, bacterial inactivation was observed with the range of 4.6-5.2 logCFU/ml at 10 and 15 °C after illumination with the 461 nm LED, while illumination with the 521 nm LED resulted in only 1.0-2.0 log reductions after 7.5h. On the other hand, no antibacterial effect was observed using the 642 nm LED treatment. The photodynamic inactivation by 461 and 521 nm LEDs was found to be greater at the set temperatures of 10 and 15 °C than at 20 °C. The D-values for the four bacterial strains at 10 and 15 °C after the illumination of 461 nm LED ranged from 1.29 to 1.74 h, indicating that there was no significant difference in the susceptibility of the bacterial strains to the LED illumination between 10 and 15 °C, except for L. monocytogenes. Regardless of the illumination temperature, sublethal injury was observed in all bacterial strains during illumination with the 461 and the 521 nm LED and the percentage of injured cells increased as the treatment time increased. Thus, the results show that the antibacterial effect of the LEDs was highly dependent on the wavelength and the illumination temperature. This study suggests the potential of 461 and 521 nm LEDs in combination with chilling to be used as a novel food preservation technology. © 2013 Elsevier B.V. All rights reserved.
An extraocular non-invasive transscleral LED-endoilluminator for eye speculum integration.
Kölbl, Philipp Simon; Lindner, Christoph; Lingenfelder, Christian; Deuchler, Svenja; Singh, Pankaj; Koch, Frank; Hessling, Martin
2015-09-01
Conventional chandelier-endoilluminators used for pars-plana vitrectomy consist of a light-emitting tip attached to an optical fibre. The tip requires introduction into the ocular space through an incision. To achieve complete illumination of the intraocular space, the introduction of more than just one tip is sometimes necessary. An extraocular vitreoretinal LED-endoilluminator discussed in this paper represents a new approach to illuminate the intraocular space. The light source is integrated into a speculum and firmly apposed to the sclera. This approach offers the advantage of effectively illuminating the interior of the eye even though the procedure is non-invasive. Furthermore, this approach significantly reduces the risk of damage to the retina by phototoxic effects. A round white LED was used as a light source. By integrating the light source into a speculum, the LED was firmly held against the sclera. Thus, the ocular space was illuminated transsclerally. As a result, indirect uniform illumination of the complete intraocular space was achieved. The prototype was developed considering the relevant international standards. Porcine eyes were used because their properties are similar to those of human eyes. Porcine eyes could be acceptably illuminated with the selected LED. The LED-endoilluminator conforms with international standards for endoillumination. Thus, possible photochemical and thermal risks are considered and reduced to a minimum. A novel LED-endoilluminator which can be attached to a speculum was developed. The system does not need any connection to an external light source and, consequently, also avoids usage of an optical fibre. Regular and uniform illumination of the intraocular space was achieved by transmitted and scattered visible irradiation, avoiding an incision. The duration of potential light exposure, compared to existing illumination systems, can be significantly increased. This is also true when the illuminator is not directly placed over the pars-plana and the distance to the retina is reduced. Only a part of the light reaches the retina and the fraction of short wavelength becomes very small. Increased safety of the system results from now being able to increase the exposure time and reduce phototoxic stress to the retina.
Laffita-Mesa, José Miguel; Bauer, Peter
2014-10-21
Epigenetics is the group of changes in the phenotype which are related with the process independently of the primary DNA sequence. These changes are intimately related with changes in the gene expression level and its profile across the body. These are mediated by histone tail modifications, DNA methylation, micro-RNAs, with chromatin remodeling remaining as the foundation of epigenetic changes. DNA methylation involves the covalent addition of methyl group to cytosine of the DNA, which is mediated by methyltransferases enzymes. DNA methylation regulates gene expression by repressing transcription, while de-methylation activates gene transcription. Several human diseases are related with the epigenetic process: cancer, Alzheimer disease, stroke, Parkinson disease, and diabetes. We present here the basis of epigenetic inheritance and show the pathogenic mechanisms relating epigenetics in human diseases, specifically with regard to neurodegeneration. We discuss current concepts aimed at understanding the contribution of epigenetics to human neurodegenerative diseases. We also discuss recent findings obtained in our and other centers regarding the ATXN2 gene that causes spinocerebellar ataxia 2 and amyotrophic lateral sclerosis. Epigenetics play a pivotal role in the pathogenesis of human diseases and in several neurodegenerative disorders, and this knowledge will illuminate the pathways in the diagnostic and therapeutic field, which ultimately will be translated into the clinic context of neurodegenerative diseases. Copyright © 2013 Elsevier España, S.L.U. All rights reserved.
The Human Microbiota, Infectious Disease, and Global Health: Challenges and Opportunities.
Waldman, Abraham J; Balskus, Emily P
2018-01-12
Despite significant advances in treating infectious diseases worldwide, morbidity and mortality associated with pathogen infection remains extraordinarily high and represents a critical scientific and global health challenge. Current strategies to combat these infectious agents include a combination of vaccines, small molecule drugs, increased hygiene standards, and disease-specific interventions. While these approaches have helped to drastically reduce the incidence and number of deaths associated with infection, continued investment in current strategies and the development of novel therapeutic approaches will be required to address these global health threats. Recently, human- and vector-associated microbiotas, the assemblages of microorganisms living on and within their hosts, have emerged as a potentially important factor mediating both infection risk and disease progression. These complex microbial communities are involved in intricate and dynamic interactions with both pathogens as well as the innate and adaptive immune systems of their hosts. Here, we discuss recent findings that have illuminated the importance of resident microbiotas in infectious disease, emphasizing opportunities for novel therapeutic intervention and future challenges for the field. Our discussion will focus on four major global health threats: tuberculosis, malaria, HIV, and enteric/diarrheal diseases. We hope this Perspective will highlight the many opportunities for chemists and chemical biologists in this field as well as inspire efforts to elucidate the mechanisms underlying established disease correlations, identify novel microbiota-based risk factors, and develop new therapeutic interventions.
Stories of chronic kidney disease: listening for the unsayable.
Makaroff, Kara L Schick; Sheilds, Laurene; Molzahn, Anita
2013-12-01
To explore individuals' stories of chronic kidney disease, particularly those aspects of experience that are difficult to discuss using language (i.e. unsayable). Chronic kidney disease is continuous, but it is also life-threatening and sometimes people ask difficult questions about life and death that can be challenging and for some, impossible to discuss. These 'unsayables' are the focus of this article. The unsayable may reside both within and beyond language. Careful analysis of narratives of illness for sayable and unsayable aspects of the experience can help illuminate new areas of concern for people with chronic kidney disease. Narrative inquiry, located in a social constructionist framework, guided this study. Secondary data analysis was conducted with 46 in-depth interviews (collected between 2008-2011) with 14 people living with chronic kidney disease. Through narrative thematic analysis, we identify that the unsayable includes the following five themes: living with death, embodied experiences that were difficult to language, that which was unthinkable, unknowable mystery and that which was untold/unheard. Whereas the first four themes attend to that which is unsayable for people living with chronic kidney disease, the last theme acknowledges that which is unsayable to people living with chronic kidney disease. Not all experiences of illness can be explicitly articulated in language. Listening for both the sayable and unsayable aspects of life with chronic and life-threatening illness is an important nursing role. © 2013 John Wiley & Sons Ltd.
A simple and low-cost structured illumination microscopy using a pico-projector
NASA Astrophysics Data System (ADS)
Özgürün, Baturay
2018-02-01
Here, development of a low-cost structured illumination microscopy (SIM) based on a pico-projector is presented. The pico-projector consists of independent red, green and blue LEDs that remove need for an external illumination source. Moreover, display element of the pico-projector serves as a pattern generating spatial light modulator. A simple lens group is employed to couple light from the projector to an epi-illumination port of a commercial microscope system. 2D sub SIM images are acquired and synthesized to surpass the diffraction limit using 40x (0.75 NA) objective. Resolution of the reconstructed SIM images is verified with a dye-and-object object and a fixed cell sample.
Chromatic perception of non-invasive lighting of cave paintings
NASA Astrophysics Data System (ADS)
Zoido, Jesús; Vazquez, Daniel; Álvarez, Antonio; Bernabeu, Eusebio; García, Ángel; Herraez, Juán A.; del Egido, Marian
2009-08-01
This work is intended to deal with the problems which arise when illuminanting Paleolithic cave paintings. We have carried out the spectral and colorimetric characterization of some paintings located in the Murcielagos (bats) cave (Zuheros, Córdoba, Spain). From this characterization, the chromatic changes produced under different lighting conditions are analysed. The damage function is also computed for the different illuminants used. From the results obtained, it is proposed an illuminant whose spectral distribution diminishes the damage by minimizing the absorption of radiation and optimises the color perception of the paintings in this cave. The procedure followed in this study can be applied to optimise the lighting systems used when illuminating any other art work
Metal-Free Photocatalyst with Visible-Light-Driven Post-Illumination Catalytic Memory.
Zhang, Qi; Wang, Hua; Li, Zhangliang; Geng, Cong; Leng, Jinhui
2017-07-05
A novel metal-free photocatalyst with post-illumination catalytic memory was fabricated by the graphitic carbon nitride (g-C 3 N 4 ), carbon nanotubes (CNTs), and graphene (Gr), in which g-C 3 N 4 acts as an efficient photocatalyst and the CNTs and Gr act as supercapacitors. The removal of phenol was achieved in the dark by post-illumination catalytic memory because the photocatalyst could store a portion of its photoactivity via photogenerated electrons in the CNTs and Gr under visible-light illumination and then release the electrons again in the dark. Therefore, this metal-free photocatalyst is capable of operation in the dark for a broad range of applications.
Reflector system for a lighting fixture
Siminovitch, Michael J.; Page, Erik; Gould, Carl T.
1998-01-01
Disclosed herein is a reflector system for a lighting fixture having a illumination source surrounded by an envelope. The reflector system includes a first reflector surrounding the illumination source. The reflector system also includes a second reflector which is non-contiguous with the first reflector and which surrounds the illumination source. The illumination source creates light rays which are reflected by the first and second reflectors. The first reflector directs light rays toward the center line of the fixture. However, the reflected rays despite being so reflected do not substantially intersect the envelope. The reflected light rays from the second reflector being directed so that they diverge from the center line of the fixture avoiding intersection with the semi-transparent envelope.
Reflector system for a lighting fixture
Siminovitch, Michael J.; Page, Erik; Gould, Carl T.
2001-01-01
Disclosed herein is a reflector system for a lighting fixture having a illumination source surrounded by an envelope. The reflector system includes a first reflector surrounding the illumination source. The reflector system also includes a second reflector which is non-contiguous with the first reflector and which surrounds the illumination source. The illumination source creates light rays which are reflected by the first and second reflectors. The first reflector directs light rays toward the center line of the fixture. However, the reflected rays despite being so reflected do not substantially intersect the envelope. The reflected light rays from the second reflector being directed so that they diverge from the center line of the fixture avoiding intersection with the semi-transparent envelope.
Lee, Robert J.; Smithson, Hannah E.
2016-01-01
We tested whether surface specularity alone supports operational color constancy – the ability to discriminate changes in illumination or reflectance. Observers viewed short animations of illuminant or reflectance changes in rendered scenes containing a single spherical surface, and were asked to classify the change. Performance improved with increasing specularity, as predicted from regularities in chromatic statistics. Peak performance was impaired by spatial rearrangements of image pixels that disrupted the perception of illuminated surfaces, but was maintained with increased surface complexity. The characteristic chromatic transformations that are available with non-zero specularity are useful for operational color constancy, particularly if accompanied by appropriate perceptual organisation. PMID:26974938
Study of polarization phenomena in Schottky CdTe diodes using infrared light illumination
NASA Astrophysics Data System (ADS)
Sato, Goro; Fukuyama, Taro; Watanabe, Shin; Ikeda, Hirokazu; Ohta, Masayuki; Ishikawa, Shin'nosuke; Takahashi, Tadayuki; Shiraki, Hiroyuki; Ohno, Ryoichi
2011-10-01
Schottky CdTe diode detectors suffer from a polarization phenomenon, which is characterized by degradation of the spectral properties over time following exposure to high bias voltage. This is considered attributable to charge accumulation at deep acceptor levels. A Schottky CdTe diode was illuminated with an infrared light for a certain period during a bias operation, and two opposite behaviors emerged. The detector showed a recovery when illuminated after the bias-induced polarization had completely progressed. Conversely, when the detector was illuminated before the emergence of bias-induced polarization, the degradation of the spectral properties was accelerated. Interpretation of these effects and discussion on the energy level of deep acceptors are presented.
Astor-Stetson, E; Lane, S
1991-08-01
Reflectance contrast (i.e., black as compared to grey figures on white ground) and display illumination were manipulated to vary the brightness contrast of Wundt-Hering figures. 16 college students and 16 older adults were presented with high, medium, and low reflectance contrast figures. For half the participants, display illumination was manipulated by covering the figures with a .5 yellow neutral density filter. Magnitude of the illusion increased significantly with increased reflectance contrast for college students, and college students were significantly more susceptible to the high contrast figures than were older adults. Display illumination had no effect on the performance of either group.
Grosges, Thomas; Barchiesi, Dominique
2018-05-31
In cancer therapy, the thermal ablation of diseased cells by embedded nanoparticles is one of the known therapies. It is based on the absorption of the energy of the illuminating laser by nanoparticles. The resulting heating of nanoparticles kills the cell where these photothermal agents are embedded. One of the main constraints of this therapy is preserving the surrounding healthy cells. Therefore, two parameters are of interest. The first one is the thermal ablation characteristic length, which corresponds to an action distance around the nanoparticles for which the temperature exceeds the ablation threshold. This critical geometric parameter is related to the expected conservation of the body temperature in the surroundings of the diseased cell. The second parameter is the temperature that should be reached to achieve active thermal agents. The temperature depends on the power of the illuminating laser, on the size of nanoparticles and on their physical properties. The purpose of this paper is to propose behavior laws under the constraints of both the body temperature at the boundary of the cell to preserve surrounding cells and an acceptable range of temperature in the target cell. The behavior laws are deduced from the finite element method, which is able to model aggregates of nanoparticles. We deduce sensitivities to the laser power and to the particle size. We show that the tuning of the temperature elevation and of the distance of action of a single nanoparticle is not significantly affected by variations of the particle size and of the laser power. Aggregates of nanoparticles are much more efficient, but represent a potential risk to the surrounding cells. Fortunately, by tuning the laser power, the thermal ablation characteristic length can be controlled.
NASA Technical Reports Server (NTRS)
Mullican, R. C.; Hayes, B. C.
1991-01-01
Preliminary results of research conducted in the late 1970's indicate that perceptual qualities of an enclosure can be influenced by the distribution of illumination within the enclosure. Subjective impressions such as spaciousness, perceptual clarity, and relaxation or tenseness, among others, appear to be related to different combinations of surface luminance. A prototype indirect ambient illumination system was developed which will allow crew members to alter surface luminance distributions within an enclosed module, thus modifying perceptual cues to match crew preferences. A traditional lensed direct lighting system was compared to the prototype utilizing the full-scale mockup of Space Station Freedom developed by Marshall Space Flight Center. The direct lensed system was installed in the habitation module with the indirect prototype deployed in the U.S. laboratory module. Analysis centered on the illuminance and luminance distributions resultant from these systems and the implications of various luminaire spacing options. All test configurations were evaluated for compliance with NASA Standard 3000, Man-System Integration Standards.
Specimen illumination apparatus with optical cavity for dark field illumination
Pinkel, Daniel; Sudar, Damir; Albertson, Donna
1999-01-01
An illumination apparatus with a specimen slide holder, an illumination source, an optical cavity producing multiple reflection of illumination light to a specimen comprising a first and a second reflective surface arranged to achieve multiple reflections of light to a specimen is provided. The apparatus can further include additional reflective surfaces to achieve the optical cavity, a slide for mounting the specimen, a coverslip which is a reflective component of the optical cavity, one or more prisms for directing light within the optical cavity, antifading solutions for improving the viewing properties of the specimen, an array of materials for analysis, fluorescent components, curved reflective surfaces as components of the optical cavity, specimen detection apparatus, optical detection equipment, computers for analysis of optical images, a plane polarizer, fiberoptics, light transmission apertures, microscopic components, lenses for viewing the specimen, and upper and lower mirrors above and below the specimen slide as components of the optical cavity. Methods of using the apparatus are also provided.
NASA Astrophysics Data System (ADS)
Rakleviciene, D.; Svegzdiene, D.; Tamulaitis, G.; Zukauskas, A.
2005-08-01
The growth rate and orientation of cress seedlings in response to the direction of illumination under clino- rotation were investigated at the initial stage of intensive hypocotyl elongation. Roots and hypocotyls growing in normal gravity conditions (1 g) and under clino-rotation at 3 rpm were illuminated with red (660 nm) or blue (450 nm) light from light-emitting diodes (LEDs). Unidirectional illumination in the direction opposite to the gravity vector promoted the growth rate of roots. Inhibition of gravitropism by clino-rotation reduced the growth of roots and stimulated the elongation of hypocotyls in both red and blue light. Illumination of roots invoked changes in the formation of gravisensing cells in the columella. Illumination under clino-rotation stimulated root statocyte growth and increased the number of amyloplasts in cells of the 3rd-6th columella rows. Also, an increase in the columella cell area, mainly caused by cell elongation in blue light and by enhanced radial growth in red light, was observed.
Inoue, Tomoyuki; Oshima, Yusuke; Hori, Yuich; Maeda, Naoyuki
2010-08-01
A new 25-gauge illuminated anterior chamber maintainer composed of a 25-gauge infusion cannula through which a 29-gauge chandelier fiber probe passes was developed for use during Descemet stripping automated endothelial keratoplasty to treat patients with advanced bullous keratopathy. This device, which is compatible with a xenon or mercury vapor illuminator to generate powerful wide-angle illumination from the cone-shaped chandelier fiber tip, is self-retained at the corneal limbus after insertion of the infusion cannula through a corneal side port. Because of its bifunctionality, that is, bright illumination and adequate irrigation flow, excellent visibility with stable anterior chamber maintenance can be concurrently obtained for Descemet stripping, endothelial graft insertion, and subsequent intraocular manipulations without the need for use of a biologic staining technique or ophthalmic viscosurgical products even in patients with severe corneal haze. This new device facilitates safe and simple intraocular manipulation during Descemet stripping automated endothelial keratoplasty.
A Context-Aware Method for Authentically Simulating Outdoors Shadows for Mobile Augmented Reality.
Barreira, Joao; Bessa, Maximino; Barbosa, Luis; Magalhaes, Luis
2018-03-01
Visual coherence between virtual and real objects is a major issue in creating convincing augmented reality (AR) applications. To achieve this seamless integration, actual light conditions must be determined in real time to ensure that virtual objects are correctly illuminated and cast consistent shadows. In this paper, we propose a novel method to estimate daylight illumination and use this information in outdoor AR applications to render virtual objects with coherent shadows. The illumination parameters are acquired in real time from context-aware live sensor data. The method works under unprepared natural conditions. We also present a novel and rapid implementation of a state-of-the-art skylight model, from which the illumination parameters are derived. The Sun's position is calculated based on the user location and time of day, with the relative rotational differences estimated from a gyroscope, compass and accelerometer. The results illustrated that our method can generate visually credible AR scenes with consistent shadows rendered from recovered illumination.
Optically controlled polarization in highly oriented ferroelectric thin films
NASA Astrophysics Data System (ADS)
Borkar, Hitesh; Tomar, M.; Gupta, Vinay; Katiyar, Ram S.; Scott, J. F.; Kumar, Ashok
2017-08-01
The out-of-plane and in-plane polarization of (Pb0.6Li0.2Bi0.2)(Zr0.2Ti0.8)O3 (PLBZT) thin film has been studied in the dark and under illumination from a weak light source of a comparable bandgap. A highly oriented PLBZT thin film was grown on a LaNiO3/LaAlO3 substrate by pulsed laser deposition; it showed well-saturated polarization which was significantly enhanced under light illumination. We employed two configurations for polarization characterization: the first deals with out-of-plane polarization with a single capacitor under investigation, whereas the second uses two capacitors connected in series via the bottom electrode. Two different configurations were illuminated using different energy sources and their effects were studied. The latter configuration shows a significant change in polarization under light illumination that may provide an extra degree of freedom for device miniaturization. The polarization was also tested using positive-up and negative-down measurements, confirming robust polarization and its switching under illumination.
Back-side hydrogenation technique for defect passivation in silicon solar cells
Sopori, Bhushan L.
1994-01-01
A two-step back-side hydrogenation process includes the steps of first bombarding the back side of the silicon substrate with hydrogen ions with intensities and for a time sufficient to implant enough hydrogen atoms into the silicon substrate to potentially passivate substantially all of the defects and impurities in the silicon substrate, and then illuminating the silicon substrate with electromagnetic radiation to activate the implanted hydrogen, so that it can passivate the defects and impurities in the substrate. The illumination step also annihilates the hydrogen-induced defects. The illumination step is carried out according to a two-stage illumination schedule, the first or low-power stage of which subjects the substrate to electromagnetic radiation that has sufficient intensity to activate the implanted hydrogen, yet not drive the hydrogen from the substrate. The second or high-power illumination stage subjects the substrate to higher intensity electromagnetic radiation, which is sufficient to annihilate the hydrogen-induced defects and sinter/alloy the metal contacts.
Back-side hydrogenation technique for defect passivation in silicon solar cells
Sopori, B.L.
1994-04-19
A two-step back-side hydrogenation process includes the steps of first bombarding the back side of the silicon substrate with hydrogen ions with intensities and for a time sufficient to implant enough hydrogen atoms into the silicon substrate to potentially passivate substantially all of the defects and impurities in the silicon substrate, and then illuminating the silicon substrate with electromagnetic radiation to activate the implanted hydrogen, so that it can passivate the defects and impurities in the substrate. The illumination step also annihilates the hydrogen-induced defects. The illumination step is carried out according to a two-stage illumination schedule, the first or low-power stage of which subjects the substrate to electromagnetic radiation that has sufficient intensity to activate the implanted hydrogen, yet not drive the hydrogen from the substrate. The second or high-power illumination stage subjects the substrate to higher intensity electromagnetic radiation, which is sufficient to annihilate the hydrogen-induced defects and sinter/alloy the metal contacts. 3 figures.
NASA Astrophysics Data System (ADS)
Krishnaswami, Venkataraman; De Luca, Giulia M. R.; Breedijk, Ronald M. P.; Van Noorden, Cornelis J. F.; Manders, Erik M. M.; Hoebe, Ron A.
2017-02-01
Fluorescence microscopy is an important tool in biomedical imaging. An inherent trade-off lies between image quality and photodamage. Recently, we have introduced rescan confocal microscopy (RCM) that improves the lateral resolution of a confocal microscope down to 170 nm. Previously, we have demonstrated that with controlled-light exposure microscopy, spatial control of illumination reduces photodamage without compromising image quality. Here, we show that the combination of these two techniques leads to high resolution imaging with reduced photodamage without compromising image quality. Implementation of spatially-controlled illumination was carried out in RCM using a line scanning-based approach. Illumination is spatially-controlled for every line during imaging with the help of a prediction algorithm that estimates the spatial profile of the fluorescent specimen. The estimation is based on the information available from previously acquired line images. As a proof-of-principle, we show images of N1E-115 neuroblastoma cells, obtained by this new setup with reduced illumination dose, improved resolution and without compromising image quality.
NASA Astrophysics Data System (ADS)
Shi, Zhemin; Taguchi, Dai; Manaka, Takaaki; Iwamoto, Mitsumasa
2016-04-01
The details of turnover process of spontaneous polarization and associated carrier motions in indium-tin oxide/poly-(vinylidene-trifluoroethylene)/pentacene/Au capacitor were analyzed by coupling displacement current measurement (DCM) and electric-field-induced optical second-harmonic generation (EFISHG) measurement. A model was set up from DCM results to depict the relationship between electric field in semiconductor layer and applied external voltage, proving that photo illumination effect on the spontaneous polarization process lied in variation of semiconductor conductivity. The EFISHG measurement directly and selectively probed the electric field distribution in semiconductor layer, modifying the model and revealing detailed carrier behaviors involving photo illumination effect, dipole reversal, and interfacial charging in the device. A further decrease of DCM current in the low voltage region under illumination was found as the result of illumination effect, and the result was argued based on the changing of the total capacitance of the double-layer capacitors.
Structural and optical properties of annealed and illuminated (Ag3AsS3)0.6(As2S3)0.4 thin films
NASA Astrophysics Data System (ADS)
Studenyak, I. P.; Neimet, Yu. Yu.; Rati, Y. Y.; Stanko, D.; Kranjčec, M.; Kökényesi, S.; Daróci, L.; Bohdan, R.
2014-11-01
(Ag3AsS3)0.6(As2S3)0.4 thin films were deposited upon a quartz substrate by rapid thermal evaporation. Structural studies of the as-deposited, annealed and illuminated films were performed using XRD, scanning electron and atomic force microscopies. Surfaces of all the films were found to be covered with Ag-rich crystalline micrometer sized cones. Thermal annealing leads to mechanical deformation of part of the cones and their detachment from the base film surface while the laser illumination leads to the new formations appearance on the surface of thin films. The spectroscopic studies of optical transmission spectra for as-deposited, annealed and illuminated thin films were carried out. The optical absorption spectra in the region of its exponential behaviour were analysed, the dispersion dependences of refractive index as well as their variation after annealing and illumination were investigated.
Beam uniformity analysis of infrared laser illuminators
NASA Astrophysics Data System (ADS)
Allik, Toomas H.; Dixon, Roberta E.; Proffitt, R. Patrick; Fung, Susan; Ramboyong, Len; Soyka, Thomas J.
2015-02-01
Uniform near-infrared (NIR) and short-wave infrared (SWIR) illuminators are desired in low ambient light detection, recognition, and identification of military applications. Factors that contribute to laser illumination image degradation are high frequency, coherent laser speckle and low frequency nonuniformities created by the laser or external laser cavity optics. Laser speckle analysis and beam uniformity improvements have been independently studied by numerous authors, but analysis to separate these two effects from a single measurement technique has not been published. In this study, profiles of compact, diode laser NIR and SWIR illuminators were measured and evaluated. Digital 12-bit images were recorded with a flat-field calibrated InGaAs camera with measurements at F/1.4 and F/16. Separating beam uniformity components from laser speckle was approximated by filtering the original image. The goal of this paper is to identify and quantify the beam quality variation of illumination prototypes, draw awareness to its impact on range performance modeling, and develop measurement techniques and methodologies for military, industry, and vendors of active sources.
NASA Astrophysics Data System (ADS)
Meola, Joseph; Absi, Anthony; Islam, Mohammed N.; Peterson, Lauren M.; Ke, Kevin; Freeman, Michael J.; Ifaraguerri, Agustin I.
2014-06-01
Hyperspectral imaging systems are currently used for numerous activities related to spectral identification of materials. These passive imaging systems rely on naturally reflected/emitted radiation as the source of the signal. Thermal infrared systems measure radiation emitted from objects in the scene. As such, they can operate at both day and night. However, visible through shortwave infrared systems measure solar illumination reflected from objects. As a result, their use is limited to daytime applications. Omni Sciences has produced high powered broadband shortwave infrared super-continuum laser illuminators. A 64-watt breadboard system was recently packaged and tested at Wright-Patterson Air Force Base to gauge beam quality and to serve as a proof-of-concept for potential use as an illuminator for a hyperspectral receiver. The laser illuminator was placed in a tower and directed along a 1.4km slant path to various target materials with reflected radiation measured with both a broadband camera and a hyperspectral imaging system to gauge performance.
NASA Technical Reports Server (NTRS)
Obenschain, A. F.; Faith, T. J.
1973-01-01
Emperical equations have been derived from measurements of solar cell photovoltaic characteristics relating light generated current, IL, and open circuit voltage, VO, to cell temperature, T, intensity of illumination, W, and 1 Mev electron fluence, phi both 2 ohm-cm and 10 ohm-cm cells were tested. The temperature dependency of IL is similar for both resistivities at 140mw/sq cm; at high temperature the coefficient varies with fluence as phi 0.18, while at low temperatures the coefficient is relatively independent of fluence. Fluence dependent degration causes a decrease in IL at a rate proportional to phi 0.153 for both resistivities. At all intensities other than 560 mw/sq cm, a linear dependence of IL on illumination was found. The temperature coefficient of voltage was, to a good approximation, independent of both temperature and illumination for both resistivities. Illumination dependence of VOC was logarithmic, while the decrease with fluence of VOC varied as phi 0.25 for both resistivities.
The twilight envelope: a user-centered approach to describing roadway illumination at night.
Andre, J; Owens, D A
2001-01-01
Visual recognition functions, such as acuity and contrast sensitivity, deteriorate rapidly over the declining luminances found during civil twilight. Thus civil twilight, a critical part of the transition between daylight and darkness, represents lighting conditions that may be useful to describe artificial illumination. Automotive headlamps project a three-dimensional beam that ranges from illumination levels comparable to daylight at the vehicle to the dark limit of civil twilight (3.3 1x) at some distance ahead. This twilight envelope is characterized as a distance beyond which foveal visual functions are severely impaired, and thus it provides a general, functional description of the useful extent of the headlamp beam. This user-centered approach to describing illumination is useful for characterizing visibility when driving at night or in other artificially lit environments. This paper discusses the twilight envelope approach and its application to intervehicle variations in headlamp systems. Actual or potential applications of this research include user-centered description of artificial illumination and driver/pedestrian safety education.
Non-contact assessment of melanin distribution via multispectral temporal illumination coding
NASA Astrophysics Data System (ADS)
Amelard, Robert; Scharfenberger, Christian; Wong, Alexander; Clausi, David A.
2015-03-01
Melanin is a pigment that is highly absorptive in the UV and visible electromagnetic spectra. It is responsible for perceived skin tone, and protects against harmful UV effects. Abnormal melanin distribution is often an indicator for melanoma. We propose a novel approach for non-contact melanin distribution via multispectral temporal illumination coding to estimate the two-dimensional melanin distribution based on its absorptive characteristics. In the proposed system, a novel multispectral, cross-polarized, temporally-coded illumination sequence is synchronized with a camera to measure reflectance under both multispectral and ambient illumination. This allows us to eliminate the ambient illumination contribution from the acquired reflectance measurements, and also to determine the melanin distribution in an observed region based on the spectral properties of melanin using the Beer-Lambert law. Using this information, melanin distribution maps can be generated for objective, quantitative assessment of skin type of individuals. We show that the melanin distribution map correctly identifies areas with high melanin densities (e.g., nevi).
NASA Technical Reports Server (NTRS)
Taranik, J. V.; Slemmons, D. B.; Bell, E. J.; Borengasser, M.; Lugaski, T. P.; Vreeland, H.; Vreeland, P.; Kleiner, E.; Peterson, F. F.; Kleiforth, H.
1984-01-01
The measurement capability provided by the Shuttle Imaging Radar (SIR-B) was used to determine: (1) the relationships between radar illumination geometry and depth of penetration in different climatic and physiographic environments in Nevada; and, (2) the relationships between radar illumination geometry and detection and analysis of structural features in different climatic and physiographic environments in Nevada.
Pigeons' Memory for Number of Events: Effects of Intertrial Interval and Delay Interval Illumination
ERIC Educational Resources Information Center
Hope, Chris; Santi, Angelo
2004-01-01
In Experiment 1, pigeons were trained at a 0-s baseline delay to discriminate sequences of light flashes (illumination of the feeder) that varied in number but not time (2f/4s and 8f/4s). During training, the intertrial interval was illuminated by the houselight for Group Light, but it was dark for Group Dark. Testing conducted with dark delay…
Illumination in diverse codimensions
NASA Technical Reports Server (NTRS)
Banks, David C.
1994-01-01
This paper derives a model of diffuse and specular illumination in arbitrarily large dimensions, based on a few characteristics of material and light in three-space. It then describes how to adjust for the anomaly of excess brightness in large codimensions. If a surface is grooved or furry, it can be illuminated with a hybrid model that incorporates both the one dimensional geometry (the grooves or fur) and the two dimensional geometry (the surface).
Color appearance of familiar objects: effects of object shape, texture, and illumination changes.
Olkkonen, Maria; Hansen, Thorsten; Gegenfurtner, Karl R
2008-05-26
People perceive roughly constant surface colors despite large changes in illumination. The familiarity of colors of some natural objects might help achieve this feat through direct modulation of the objects' color appearance. Research on memory colors and color appearance has yielded controversial results and due to the employed methods has often confounded perceptual with semantic effects. We studied the effect of memory colors on color appearance by presenting photographs of fruit on a monitor under various simulated illuminations and by asking observers to make either achromatic or typical color settings without placing demands on short-term memory or semantic processing. In a control condition, we presented photographs of 3D fruit shapes without texture and 2D outline shapes. We found that (1) achromatic settings for fruit were systematically biased away from the gray point toward the opposite direction of a fruit's memory color; (2) the strength of the effect depended on the degree of naturalness of the stimuli; and (3) the effect was evident under all tested illuminations, being strongest for illuminations whose chromaticity was closest to the stimulus chromaticity. We conclude that the visual identity of an object has a measurable effect on color perception, and that this effect is robust under illuminant changes, indicating its potential significance as an additional mechanism for color constancy.
Quantitative studies of animal colour constancy: using the chicken as model
2016-01-01
Colour constancy is the capacity of visual systems to keep colour perception constant despite changes in the illumination spectrum. Colour constancy has been tested extensively in humans and has also been described in many animals. In humans, colour constancy is often studied quantitatively, but besides humans, this has only been done for the goldfish and the honeybee. In this study, we quantified colour constancy in the chicken by training the birds in a colour discrimination task and testing them in changed illumination spectra to find the largest illumination change in which they were able to remain colour-constant. We used the receptor noise limited model for animal colour vision to quantify the illumination changes, and found that colour constancy performance depended on the difference between the colours used in the discrimination task, the training procedure and the time the chickens were allowed to adapt to a new illumination before making a choice. We analysed literature data on goldfish and honeybee colour constancy with the same method and found that chickens can compensate for larger illumination changes than both. We suggest that future studies on colour constancy in non-human animals could use a similar approach to allow for comparison between species and populations. PMID:27170714
NASA Astrophysics Data System (ADS)
Mo, Weirong; Mohan, Rachit; Li, Weizhi; Zhang, Xu; Sellke, Eric W.; Fan, Wensheng; DiMaio, J. Michael; Thatcher, Jeffery E.
2015-02-01
We present a non-contact, reflective photoplethysmogram (PPG) imaging method and a prototype system for identifying the presence of dermal burn wounds during a burn debridement surgery. This system aims to provide assistance to clinicians and surgeons in the process of dermal wound management and wound triage decisions. We examined the system variables of illumination uniformity and intensity and present our findings. An LED array, a tungsten light source, and eventually high-power LED emitters were studied as illumination methods for our PPG imaging device. These three different illumination sources were tested in a controlled tissue phantom model and an animal burn model. We found that the low heat and even illumination pattern using high power LED emitters provided a substantial improvement to the collected PPG signal in our animal burn model. These improvements allow the PPG signal from different pixels to be comparable in both time-domain and frequency-domain, simplify the illumination subsystem complexity, and remove the necessity of using high dynamic range cameras. Through the burn model output comparison, such as the blood volume in animal burn data and controlled tissue phantom model, our optical improvements have led to more clinically applicable images to aid in burn assessment.
Micromilled optical elements for edge-lit illumination panels
NASA Astrophysics Data System (ADS)
Ronny, Rahima Afrose; Knopf, George K.; Bordatchev, Evgueni; Nikumb, Suwas
2013-04-01
Edge-lit light guide panels (LGPs) with micropatterned surfaces represent a new technology for developing small- and medium-sized illumination sources for application such as automotive, residential lighting, and advertising displays. The shape, density, and spatial distribution of the micro-optical structures (MOSs) imprinted on the transparent LGP must be selected to achieve high brightness and uniform luminance over the active surface. We examine how round-tip cylindrical MOSs fabricated by precision micromilling can be used to create patterned surfaces on low-cost transparent polymethyl-methacrylate substrates for high-intensity illumination applications. The impact of varying the number, pitch, spatial distribution, and depth of the optical microstructures on lighting performance is initially investigated using LightTools™ simulation software. To illustrate the microfabrication process, several 100×100×6 mm3 LGP prototypes are constructed and tested. The prototypes include an "optimized" array of MOSs that exhibit near-uniform illumination (approximately 89%) across its active light-emitting surface. Although the average illumination was 7.3% less than the value predicted from numerical simulation, it demonstrates how LGPs can be created using micromilling operations. Customized MOS arrays with a bright rectangular pattern near the center of the panel and a sequence of MOSs that illuminate a predefined logo are also presented.
To compute lightness, illumination is not estimated, it is held constant.
Gilchrist, Alan L
2018-05-03
The light reaching the eye from a surface does not indicate the black-gray-white shade of a surface (called lightness) because the effects of illumination level are confounded with the reflectance of the surface. Rotating a gray paper relative to a light source alters its luminance (intensity of light reaching the eye) but the lightness of the paper remains relatively constant. Recent publications have argued, as had Helmholtz (1866/1924), that the visual system unconsciously estimates the direction and intensity of the light source. We report experiments in which this theory was pitted against an alternative theory according to which illumination level and surface reflectance are disentangled by comparing only those surfaces that are equally illuminated, in other words, by holding illumination level constant. A 3-dimensional scene was created within which the rotation of a target surface would be expected to become darker gray according to the lighting estimation theory, but lighter gray according to the equi-illumination comparison theory, with results clearly favoring the latter. In a further experiment cues held to indicate light source direction (cast shadows, attached shadows, and glossy highlights) were completely eliminated and yet this had no effect on the results. (PsycINFO Database Record (c) 2018 APA, all rights reserved).