Sample records for mov reliability evaluation

  1. Application of reliability-centered maintenance to boiling water reactor emergency core cooling systems fault-tree analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Choi, Y.A.; Feltus, M.A.

    1995-07-01

    Reliability-centered maintenance (RCM) methods are applied to boiling water reactor plant-specific emergency core cooling system probabilistic risk assessment (PRA) fault trees. The RCM is a technique that is system function-based, for improving a preventive maintenance (PM) program, which is applied on a component basis. Many PM programs are based on time-directed maintenance tasks, while RCM methods focus on component condition-directed maintenance tasks. Stroke time test data for motor-operated valves (MOVs) are used to address three aspects concerning RCM: (a) to determine if MOV stroke time testing was useful as a condition-directed PM task; (b) to determine and compare the plant-specificmore » MOV failure data from a broad RCM philosophy time period compared with a PM period and, also, compared with generic industry MOV failure data; and (c) to determine the effects and impact of the plant-specific MOV failure data on core damage frequency (CDF) and system unavailabilities for these emergency systems. The MOV stroke time test data from four emergency core cooling systems [i.e., high-pressure coolant injection (HPCI), reactor core isolation cooling (RCIC), low-pressure core spray (LPCS), and residual heat removal/low-pressure coolant injection (RHR/LPCI)] were gathered from Philadelphia Electric Company`s Peach Bottom Atomic Power Station Units 2 and 3 between 1980 and 1992. The analyses showed that MOV stroke time testing was not a predictor for eminent failure and should be considered as a go/no-go test. The failure data from the broad RCM philosophy showed an improvement compared with the PM-period failure rates in the emergency core cooling system MOVs. Also, the plant-specific MOV failure rates for both maintenance philosophies were shown to be lower than the generic industry estimates.« less

  2. A soft computing scheme incorporating ANN and MOV energy in fault detection, classification and distance estimation of EHV transmission line with FSC.

    PubMed

    Khadke, Piyush; Patne, Nita; Singh, Arvind; Shinde, Gulab

    2016-01-01

    In this article, a novel and accurate scheme for fault detection, classification and fault distance estimation for a fixed series compensated transmission line is proposed. The proposed scheme is based on artificial neural network (ANN) and metal oxide varistor (MOV) energy, employing Levenberg-Marquardt training algorithm. The novelty of this scheme is the use of MOV energy signals of fixed series capacitors (FSC) as input to train the ANN. Such approach has never been used in any earlier fault analysis algorithms in the last few decades. Proposed scheme uses only single end measurement energy signals of MOV in all the 3 phases over one cycle duration from the occurrence of a fault. Thereafter, these MOV energy signals are fed as input to ANN for fault distance estimation. Feasibility and reliability of the proposed scheme have been evaluated for all ten types of fault in test power system model at different fault inception angles over numerous fault locations. Real transmission system parameters of 3-phase 400 kV Wardha-Aurangabad transmission line (400 km) with 40 % FSC at Power Grid Wardha Substation, India is considered for this research. Extensive simulation experiments show that the proposed scheme provides quite accurate results which demonstrate complete protection scheme with high accuracy, simplicity and robustness.

  3. Advanced Technology Training System on Motor-Operated Valves

    NASA Technical Reports Server (NTRS)

    Wiederholt, Bradley J.; Widjaja, T. Kiki; Yasutake, Joseph Y.; Isoda, Hachiro

    1993-01-01

    This paper describes how features from the field of Intelligent Tutoring Systems are applied to the Motor-Operated Valve (MOV) Advanced Technology Training System (ATTS). The MOV ATTS is a training system developed at Galaxy Scientific Corporation for the Central Research Institute of Electric Power Industry in Japan and the Electric Power Research Institute in the United States. The MOV ATTS combines traditional computer-based training approaches with system simulation, integrated expert systems, and student and expert modeling. The primary goal of the MOV ATTS is to reduce human errors that occur during MOV overhaul and repair. The MOV ATTS addresses this goal by providing basic operational information of the MOV, simulating MOV operation, providing troubleshooting practice of MOV failures, and tailoring this training to the needs of each individual student. The MOV ATTS integrates multiple expert models (functional and procedural) to provide advice and feedback to students. The integration also provides expert model validation support to developers. Student modeling is supported by two separate student models: one model registers and updates the student's current knowledge of basic MOV information, while another model logs the student's actions and errors during troubleshooting exercises. These two models are used to provide tailored feedback to the student during the MOV course.

  4. RNA helicase MOV10 functions as a co-factor of HIV-1 Rev to facilitate Rev/RRE-dependent nuclear export of viral mRNAs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Feng; Zhang, Junsong; Zhang, Yijun

    Human immunodeficiency virus type 1 (HIV-1) exploits multiple host factors during its replication. The REV/RRE-dependent nuclear export of unspliced/partially spliced viral transcripts needs the assistance of host proteins. Recent studies have shown that MOV10 overexpression inhibited HIV-1 replication at various steps. However, the endogenous MOV10 was required in certain step(s) of HIV-1 replication. In this report, we found that MOV10 potently enhances the nuclear export of viral mRNAs and subsequently increases the expression of Gag protein and other late products through affecting the Rev/RRE axis. The co-immunoprecipitation analysis indicated that MOV10 interacts with Rev in an RNA-independent manner. The DEAG-boxmore » of MOV10 was required for the enhancement of Rev/RRE-dependent nuclear export and the DEAG-box mutant showed a dominant-negative activity. Our data propose that HIV-1 utilizes the anti-viral factor MOV10 to function as a co-factor of Rev and demonstrate the complicated effects of MOV10 on HIV-1 life cycle. - Highlights: • MOV10 can function as a co-factor of HIV-1 Rev. • MOV10 facilitates Rev/RRE-dependent transport of viral mRNAs. • MOV10 interacts with Rev in an RNA-independent manner. • The DEAG-box of MOV10 is required for the enhancement of Rev/RRE-dependent export.« less

  5. Update on Multiple Ovulations in Dairy Cattle

    PubMed Central

    Macmillan, Kira; Kastelic, John P.

    2018-01-01

    Simple Summary Multiple ovulations (MOV) in cattle can lead to twin pregnancies, which negatively affects the health, production, and reproduction of cows. Despite many studies, the causal mechanisms behind MOV are still not well understood. There is a general agreement that MOV are more likely during periods of low progesterone (P4), which may increase the luteinizing hormone (LH) release at the time of selection, resulting in more than one follicle becoming dominant. The MOV rate also increases in older cows and when the selection of a dominant follicle occurs concurrently with a high milk yield. Additional risk factors for MOV are ovarian cysts, diet, season, and genetics. A better understanding of the mechanisms underlying MOV may help to mitigate twinning, perhaps through the appropriate reproductive management protocols or genetic selection. Abstract This review updates the causal mechanisms and risk factors for multiple ovulations (MOV) in cattle. Clearly, MOV can lead to twin pregnancies, which negatively affects the health, production, and reproduction of cows. Therefore, a better understanding of the factors causing MOV may help to reduce twinning. Multiple ovulations occur after two or more follicles deviate and achieve codominance. The MOV rate is influenced by a complex network of hormones. For example, MOV is more common during periods of low progesterone (P4), that is, in anovulatory cattle or when luteolysis coincides with the selection of the future ovulatory follicle. There is also strong evidence for the luteinizing hormone (LH) being the primary factor leading to codominance, as high P4 concentrations suppress the transient LH surges and can reduce the ovulation rate in cattle or even inhibit deviation. Rates of MOV are increased in older and higher-producing dairy cows. Increased milk production and dry matter intake (DMI) increases hormone clearance, including P4; however, the association between milk yield and MOV has not been consistent. Additional risk factors for MOV include ovarian cysts, diet, season, and genetics. PMID:29695075

  6. 78 FR 17290 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-21

    ... the motor-operated valve (MOV) actuators of the main and center fuel tanks; replacing certain MOV actuators with new MOV actuators; and measuring the electrical resistance of the bond from the adapter plate... prevent electrical current from flowing through an MOV actuator into a fuel tank, which could create a...

  7. Update on Multiple Ovulations in Dairy Cattle.

    PubMed

    Macmillan, Kira; Kastelic, John P; Colazo, Marcos G

    2018-04-24

    This review updates the causal mechanisms and risk factors for multiple ovulations (MOV) in cattle. Clearly, MOV can lead to twin pregnancies, which negatively affects the health, production, and reproduction of cows. Therefore, a better understanding of the factors causing MOV may help to reduce twinning. Multiple ovulations occur after two or more follicles deviate and achieve codominance. The MOV rate is influenced by a complex network of hormones. For example, MOV is more common during periods of low progesterone (P4), that is, in anovulatory cattle or when luteolysis coincides with the selection of the future ovulatory follicle. There is also strong evidence for the luteinizing hormone (LH) being the primary factor leading to codominance, as high P4 concentrations suppress the transient LH surges and can reduce the ovulation rate in cattle or even inhibit deviation. Rates of MOV are increased in older and higher-producing dairy cows. Increased milk production and dry matter intake (DMI) increases hormone clearance, including P4; however, the association between milk yield and MOV has not been consistent. Additional risk factors for MOV include ovarian cysts, diet, season, and genetics.

  8. Exercise-Based Performance Enhancement and Injury Prevention for Firefighters: Contrasting the Fitness- and Movement-Related Adaptations to Two Training Methodologies.

    PubMed

    Frost, David M; Beach, Tyson A C; Callaghan, Jack P; McGill, Stuart M

    2015-09-01

    Using exercise to enhance physical fitness may have little impact on performers' movement patterns beyond the gym environment. This study examined the fitness and movement adaptations exhibited by firefighters in response to 2 training methodologies. Fifty-two firefighters were assigned to a movement-guided fitness (MOV), conventional fitness (FIT), or control (CON) group. Before and after 12 weeks of training, participants performed a fitness evaluation and laboratory-based test. Three-dimensional lumbar spine and frontal plane knee kinematics were quantified. Five whole-body tasks not included in the interventions were used to evaluate the transfer of training. FIT and MOV groups exhibited significant improvements in all aspects of fitness; however, only MOV exhibited improvements in spine and frontal plane knee motion control when performing each transfer task (effect sizes [ESs] of 0.2-1.5). FIT exhibited less controlled spine and frontal plane knee motions while squatting, lunging, pushing, and pulling (ES: 0.2-0.7). More MOV participants (43%) exhibited only positive posttraining changes (i.e., improved control), in comparison with FIT (30%) and CON (23%). Fewer negative posttraining changes were also noted (19, 25, and 36% for MOV, FIT, and CON). These findings suggest that placing an emphasis on how participants move while exercising may be an effective training strategy to elicit behavioral changes beyond the gym environment. For occupational athletes such as firefighters, soldiers, and police officers, this implies that exercise programs designed with a movement-oriented approach to periodization could have a direct impact on their safety and effectiveness by engraining desirable movement patterns that transfer to occupational tasks.

  9. Ovarian volume and gluco-insulinaemic markers in the diagnosis of PCOS during adolescence.

    PubMed

    Villa, Paola; Rossodivita, Aurora; Sagnella, Francesca; Moruzzi, Maria Cristina; Mariano, Nicoletta; Lassandro, Anna Pia; Pontecorvi, Alfredo; Scambia, Giovanni; Lanzone, Antonio

    2013-02-01

    To evaluate the role of mean ovarian volume (MOV) in the diagnosis of polycystic ovary syndrome (PCOS) during adolescence, and its relationship with metabolic and endocrine parameters. Observational study. A total of 134 young girls, including 86 adolescents with PCOS and 48 controls, were studied. During the early follicular phase, a pelvic ultrasound examination was performed to measure the ovarian volume of both ovaries and to calculate the MOV. All subjects underwent hormonal assessment and an ultrasound examination. PCOS subjects were submitted to an oral glucose tolerance test. The homeostasis model assessment for insulin resistance (HOMA-IR) and several insulin resistance indexes were also determined. Androgens, free androgen index (FAI), LH and insulin resistance indexes were higher in the PCOS group. MOV was significantly different between the two groups: control group 4·6 ± 1·9 cm(3) , adolescent PCOS group 9·6 ± 4·4 cm(3) . The MOV threshold of 5·596 cm(3) offered the best compromise between sensitivity and specificity based on the characteristics of the operating receiver curve analysis. Therefore, an ovarian volume higher than 5·6 increased the risk of PCOS by about 15 times (OR 16·25 IC 95% 6·3-41·3). In adolescent PCOS girls, the ovarian volume was significantly associated with circulating testosterone and insulin, and indices of insulin resistance. During early adolescence MOV evaluation may offer an effective means to screen and follow up young girls with irregular cycles in order to prevent the long-term metabolic disturbances of the polycystic ovary syndrome. © 2012 Blackwell Publishing Ltd.

  10. Interplay between RNASEH2 and MOV10 controls LINE-1 retrotransposition

    PubMed Central

    Choi, Jongsu; Hwang, Sung-Yeon; Ahn, Kwangseog

    2018-01-01

    Abstract Long interspersed nuclear element 1 is an autonomous non-long terminal repeat retrotransposon that comprises ∼17% of the human genome. Its spontaneous retrotransposition and the accumulation of heritable L1 insertions can potentially result in genome instability and sporadic disorders. Moloney leukemia virus 10 homolog (MOV10), a putative RNA helicase, has been implicated in inhibiting L1 replication, although its underlying mechanism of action remains obscure. Moreover, the physiological relevance of MOV10-mediated L1 regulation in human disease has not yet been examined. Using a proteomic approach, we identified RNASEH2 as a binding partner of MOV10. We show that MOV10 interacts with RNASEH2, and their interplay is crucial for restricting L1 retrotransposition. RNASEH2 and MOV10 co-localize in the nucleus, and RNASEH2 binds to L1 RNAs in a MOV10-dependent manner. Small hairpin RNA-mediated depletion of either RNASEH2A or MOV10 results in an accumulation of L1-specific RNA-DNA hybrids, suggesting they contribute to prevent formation of vital L1 heteroduplexes during retrotransposition. Furthermore, we show that RNASEH2-MOV10-mediated L1 restriction downregulates expression of the rheumatoid arthritis-associated inflammatory cytokines and matrix-degrading proteinases in synovial cells, implicating a potential causal relationship between them and disease development in terms of disease predisposition. PMID:29315404

  11. RNA helicase MOV10 functions as a co-factor of HIV-1 Rev to facilitate Rev/RRE-dependent nuclear export of viral mRNAs.

    PubMed

    Huang, Feng; Zhang, Junsong; Zhang, Yijun; Geng, Guannan; Liang, Juanran; Li, Yingniang; Chen, Jingliang; Liu, Chao; Zhang, Hui

    2015-12-01

    Human immunodeficiency virus type 1 (HIV-1) exploits multiple host factors during its replication. The REV/RRE-dependent nuclear export of unspliced/partially spliced viral transcripts needs the assistance of host proteins. Recent studies have shown that MOV10 overexpression inhibited HIV-1 replication at various steps. However, the endogenous MOV10 was required in certain step(s) of HIV-1 replication. In this report, we found that MOV10 potently enhances the nuclear export of viral mRNAs and subsequently increases the expression of Gag protein and other late products through affecting the Rev/RRE axis. The co-immunoprecipitation analysis indicated that MOV10 interacts with Rev in an RNA-independent manner. The DEAG-box of MOV10 was required for the enhancement of Rev/RRE-dependent nuclear export and the DEAG-box mutant showed a dominant-negative activity. Our data propose that HIV-1 utilizes the anti-viral factor MOV10 to function as a co-factor of Rev and demonstrate the complicated effects of MOV10 on HIV-1 life cycle. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. MovAid- a novel device for advanced rehabilitation monitoring.

    PubMed

    Gupta, Prashant; Verma, Piyush; Gupta, Rakesh; Verma, Bhawna

    2015-08-01

    The present article introduces a new device "MovAid" which helps to measure and monitor rehabilitation. It has two main components- "MovAid device" and the "MovAid Smart Phone Application". The device connects wirelessly to the MovAid smart phone application via Bluetooth. It has electronic sensors to measure three important parameters of the patient- Angle of Joint Bent, Lift from the ground and Orientation of the limb. A mono-axis flex sensor to measure the degree of joint bent and a 3-axis accelerometer and gyroscope to measure the orientation of the limb and lift from the ground have been used. MovAid system bridges the gap between caretakers and patients, empowering both in ways never thought of before, by providing detailed and accurate data on every move.

  13. Distribution of OV-TL 3 and MOv18 in normal and malignant ovarian tissue.

    PubMed

    Buist, M R; Molthoff, C F; Kenemans, P; Meijer, C J

    1995-07-01

    To analyse the distribution of OV-TL 3 and MOv18 in normal ovarian tissue to determine which antibody is most suitable for (radio)immunotherapy of ovarian carcinoma. The distribution of OV-TL 3 and MOv18 was determined using immunohistochemistry and flow cytometry. Epithelial and other cells in many tissues, and leucocytes in peripheral blood, bone marrow and spleen stained positively with OV-TL 3. The staining pattern of MOv18 in normal tissues was more restricted and was confined to epithelial cells in the lung, kidney, pancreas, salivary gland, ovary, Fallopian tubes, and cervix. Reactivity was also observed with pneumocytes in the lung, tubuli in the kidney, acinar cells in the salivary gland and pancreas, in the placenta, and with Kupffer cells in the liver. The staining pattern of chimeric MOv18 was identical with the murine form. OV-TL 3 and MOv18 reacted with 100% and 98% (45/46) of the 46 tested epithelial ovarian cancers, respectively. In ovarian carcinoma tissue homogeneous staining of epithelial cells was observed with OV-TL 3 and more heterogeneous staining with MOv18. In 12 and nine patients, respectively, a difference in staining intensity for OV-TL 3 and MOv18 was observed between various tumour samples from the same patient. MOv18 has greater therapeutic potential because of its restricted reactivity with normal tissues and especially, in contrast to OV-TL 3, its lack of reactivity with haematopoietic cells.

  14. Generation of monoclonal antibodies reacting with human epithelial ovarian cancer.

    PubMed

    Tagliabue, E; Mènard, S; Della Torre, G; Barbanti, P; Mariani-Costantini, R; Porro, G; Colnaghi, M I

    1985-01-01

    Fusion of the murine myeloma line P3-X63-Ag8-U1 with spleen cells from a mouse immunized with a membrane preparations (CM) of a mucinous ovarian cystoadenocarcinoma yielded two monoclonal antibodies, MOv1 and MOv2, which reacted by solid-phase radioimmunoassay with immunizing tumor CM but were unreactive with normal kidney CM as well as with plasma proteins and peripheral blood cells from the immunizing carcinoma patient. MOv1 and MOv2 were further tested by solid-phase radioimunoassay on a panel of different CM from fresh surgical specimens of ovarian and nonovarian carcinomas, benign ovarian tumors, normal ovary and kidney tissues, and on various tumor cell lines. In addition, the antibodies were characterized by immunofluorescence on live cells from cell lines and surgical specimens, and on frozen sections of benign and malignant ovarian tumors, of nonovarian tumors, and of normal tissues. The results obtained indicate that MOv1 and MOv2 recognize two different epitopes on molecules present on malignant and benign ovarian mucinous tumors and colonic glands. In addition, the antigen recognized by MOv2 was also detected in carcinmas of lung, colon, stomach, and breast; in gastrointestinal glands; and in the glandular lumina of normal lactating breast.

  15. Effect of different ventilation regimens on ewes' milk and Canestrato Pugliese cheese quality in summer.

    PubMed

    Albenzio, Marzia; Santillo, Antonella; Caroprese, Mariangela; Marino, Rosaria; Centoducati, Pasquale; Sevi, Agostino

    2005-11-01

    The influence of three different ventilation regimens on air pollution in sheep houses and on the quality of ewe milk and of Canestrato Pugliese cheese was investigated during the summer season. The experimental treatments were low ventilation regimen (VR=35 m3/h per ewe) split in 30-min ventilation cycles (LOV-30); moderate ventilation regimen (VR=70 m3/h per ewe) split in 30-min ventilation cycles (MOV-30); moderate ventilation regimen (VR=70 m3/h per ewe) split in 60-min ventilation cycles (MOV-60). The LOV-30 milk had higher microbial load and bulk milk somatic cell count (BMSCC) and resulted in a weaker casein matrix in the curd compared with the MOV-30 and MOV-60 treatments. At 45 d of ripening, the LOV-30 cheeses had a lower casein content and higher non-casein nitrogen (NCN) and water-soluble nitrogen (WSN) contents than the MOV-30 and MOV-60 cheeses. Urea-polyacrylamide gel electrophoresis (urea-PAGE) of the pH 4.6-soluble N extract showed that the MOV-60 cheeses had fewer bands derived from casein (CN) hydrolysis than the LOV-30 or MOV-30 cheeses, despite its having exhibited the highest plasmin (PL) activity levels. Our results suggest that the ventilation regimen is critical in dairy sheep housing for optimizing the hygienic quality of ewe milk and the proteolytic processes occurring in Canestrato Pugliese cheese during ripening.

  16. Electrical insulation design requirements and reliability goals

    NASA Astrophysics Data System (ADS)

    Ross, R. G., Jr.

    1983-11-01

    The solar cells in a photovoltaic module which must be electrically isolated from module exterior surfaces to satisfy a variety of safety and operating considerations are discussed. The performance and reliability of the insulation system are examined. Technical requirements involve the capability of withstanding the differential voltage from the solar cells to the module frame. The maximum system voltage includes consideration of maximum open circuit array voltages achieved under low-temperature, high-irradiance conditions, and transient overvoltages due to system feedback of lightning transients. The latter is bounded by the characteristics of incorporated voltage limiting devices such as MOVs.

  17. A Fault Location Algorithm for Two-End Series-Compensated Double-Circuit Transmission Lines Using the Distributed Parameter Line Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kang, Ning; Gombos, Gergely; Mousavi, Mirrasoul J.

    A new fault location algorithm for two-end series-compensated double-circuit transmission lines utilizing unsynchronized two-terminal current phasors and local voltage phasors is presented in this paper. The distributed parameter line model is adopted to take into account the shunt capacitance of the lines. The mutual coupling between the parallel lines in the zero-sequence network is also considered. The boundary conditions under different fault types are used to derive the fault location formulation. The developed algorithm directly uses the local voltage phasors on the line side of series compensation (SC) and metal oxide varistor (MOV). However, when potential transformers are not installedmore » on the line side of SC and MOVs for the local terminal, these measurements can be calculated from the local terminal bus voltage and currents by estimating the voltages across the SC and MOVs. MATLAB SimPowerSystems is used to generate cases under diverse fault conditions to evaluating accuracy. The simulation results show that the proposed algorithm is qualified for practical implementation.« less

  18. Purification and properties of formate dehydrogenase from Pseudomonas aeruginosa. Electron-paramagnetic-resonance studies on the molybdenum centre.

    PubMed Central

    Gadsby, P M; Greenwood, C; Coddington, A; Thomson, A J; Godfrey, C

    1987-01-01

    Formate dehydrogenase from Pseudomonas aeruginosa contains molybdenum, a [4Fe-4S] cluster and cytochrome b. This paper reports the detection of molybdenum as Mo(V) by e.p.r. spectroscopy. In order to generate Mo(V) signals, addition of amounts of excess formate varying between 10- and 50-fold over enzyme, followed by 200-fold excess of sodium dithionite, were used. Two Mo(V) species were observed. One, the major component, has g1 = 2.012, g2 = 1.985 and g3 = 1.968, appeared at low concentrations of formate and increased linearly in intensity with increasing concentrations of formate up to 25-fold excess over the enzyme. At higher formate concentration this signal disappeared. The appearance and disappearance of this Mo(V) signal seems to parallel the state of reduction of the [4Fe-4S] clusters. A second, minor, Mo(V) species with g-values g1 = 1.996, g2 = 1.981 and g3 = 1.941 appears at a constant level during the formate-dithionite titration. No evidence has been obtained for nuclear hyperfine coupling to protons. The major Mo(V) species has unusual e.p.r. signals compared with other molybdenum-containing enzymes, except for that observed in the formate dehydrogenase from Methanobacterium formicicum [Barber, Siegel, Schauer, May & Ferry (1983) J. Biol. Chem. 258, 10839-10845]. The present work suggests that the enzyme is acting as a CO2 reductase, with dithionite as an electron donor to a [4Fe-4S] cluster, which in turn donates electrons to molybdenum, producing a Mo(V) species with CO2 bound to the metal. PMID:3038082

  19. Apparatus and method for non-invasive diagnosis and control of motor operated valve condition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lyon, R.H.; Chai, J.; Lang, J.H.

    1997-01-14

    An apparatus compares the torque from an MOV motor with the valve displacement, and from the comparison assesses MOV operating condition. A transducer measures the vibration of the housing of an MOV. The vibrations are due to the motions of the rotating elements within the housing, which motions are directly related to the motion of the valve relative to its seat. Signal processing apparatus analyzes the vibrations to recover the rotations of the rotating elements and thus the motion of the valve plug. Lost motion can also be determined (if a lost motion connection exists) by demodulating the vibration signalmore » and thus taking into account also the lost motion. Simultaneously, the forces applied to the valve are estimated by estimating the torque between the stator and the rotor of the motor. Such torque can be estimated from measuring the input current and voltage alone, using a forgetting factor and a correction for the forgetting factor. A signature derived from relating the torque to the valve position can be used to assess the condition of the MOV, by comparing the signature to signatures for MOVs of known conditions. The vibration analysis components generate signals that relate to the position of elements in the operator. Similarly, the torque estimator estimates the torque output by any type of electric motor, whether or not part of an MOV analysis unit. 28 figs.« less

  20. Apparatus and method for non-invasive diagnosis and control of motor operated valve condition

    DOEpatents

    Lyon, R.H.; Chai, J.; Lang, J.H.; Hagman, W.H.; Umans, S.D.; Saarela, O.J.

    1997-01-14

    An apparatus compares the torque from an MOV motor with the valve displacement, and from the comparison assesses MOV operating condition. A transducer measures the vibration of the housing of an MOV. The vibrations are due to the motions of the rotating elements within the housing, which motions are directly related to the motion of the valve relative to its seat. Signal processing apparatus analyzes the vibrations to recover the rotations of the rotating elements and thus the motion of the valve plug. Lost motion can also be determined (if a lost motion connection exists) by demodulating the vibration signal and thus taking into account also the lost motion. Simultaneously, the forces applied to the valve are estimated by estimating the torque between the stator and the rotor of the motor. Such torque can be estimated from measuring the input current and voltage alone, using a forgetting factor and a correction for the forgetting factor. A signature derived from relating the torque to the valve position can be used to assess the condition of the MOV, by comparing the signature to signatures for MOVs of known conditions. The vibration analysis components generate signals that relate to the position of elements in the operator. Similarly, the torque estimator estimates the torque output by any type of electric motor, whether or not part of an MOV analysis unit. 28 figs.

  1. Apparatus and method for non-invasive diagnosis and control of motor operated valve condition

    DOEpatents

    Lyon, Richard H.; Chai, Jangbom; Lang, Jeffrey H.; Hagman, Wayne H.; Umans, Stephen D.; Saarela, Olli J.

    1997-01-01

    An apparatus compares the torque from an MOV motor with the valve displacement, and from the comparison assesses MOV operating condition. A transducer measures the vibration of the housing of an MOV. The vibrations are due to the motions of the rotating elements within the housing, which motions are directly related to the motion of the valve relative to its seat. Signal processing apparatus analyzes the vibrations to recover the rotations of the rotating elements and thus the motion of the valve plug. Lost motion can also be determined (if a lost motion connection exists) by demodulating the vibration signal and thus taking into account also the lost motion. Simultaneously, the forces applied to the valve are estimated by estimating the torque between the stator and the rotor of the motor. Such torque can be estimated from measuring the input current and voltage alone, using a forgetting factor and a correction for the forgetting factor. A signature derived from relating the torque to the valve position can be used to assess the condition of the MOV, by comparing the signature to signatures for MOVs of known conditions. The vibration analysis components generate signals that relate to the position of elements in the operator. Similarly, the torque estimator estimates the torque output by any type of electric motor, whether or not part of an MOV analysis unit.

  2. Decomposing the gap in missed opportunities for vaccination between poor and non-poor in sub-Saharan Africa: A Multicountry Analyses.

    PubMed

    Ndwandwe, Duduzile; Uthman, Olalekan A; Adamu, Abdu A; Sambala, Evanson Z; Wiyeh, Alison B; Olukade, Tawa; Bishwajit, Ghose; Yaya, Sanni; Okwo-Bele, Jean-Marie; Wiysonge, Charles S

    2018-04-24

    Understanding the gaps in missed opportunities for vaccination (MOV) in sub-Saharan Africa would inform interventions for improving immunisation coverage to achieving universal childhood immunisation. We aimed to conduct a multicountry analyses to decompose the gap in MOV between poor and non-poor in SSA. We used cross-sectional data from 35 Demographic and Health Surveys in SSA conducted between 2007 and 2016. Descriptive statistics used to understand the gap in MOV between the urban poor and non-poor, and across the selected covariates. Out of the 35 countries included in this analysis, 19 countries showed pro-poor inequality, 5 showed pro-non-poor inequality and remaining 11 countries showed no statistically significant inequality. Among the countries with statistically significant pro-illiterate inequality, the risk difference ranged from 4.2% in DR Congo to 20.1% in Kenya. Important factors responsible for the inequality varied across countries. In Madagascar, the largest contributors to inequality in MOV were media access, number of under-five children, and maternal education. However, in Liberia media access narrowed inequality in MOV between poor and non-poor households. The findings indicate that in most SSA countries, children belonging to poor households are most likely to have MOV and that socio-economic inequality in is determined not only by health system functions, but also by factors beyond the scope of health authorities and care delivery system. The findings suggest the need for addressing social determinants of health.

  3. Mo(V) co-ordination in the periplasmic nitrate reductase from Paracoccus pantotrophus probed by electron nuclear double resonance (ENDOR) spectroscopy.

    PubMed Central

    Butler, Clive S; Fairhurst, Shirley A; Ferguson, Stuart J; Thomson, Andrew J; Berks, Ben C; Richardson, David J; Lowe, David J

    2002-01-01

    The first electron nuclear double resonance (ENDOR) study of a member of the Mo-bis-molybdopterin guanine dinucleotide family of molybdoenzymes is presented, using the periplasmic nitrate reductase from Paracoccus pantotrophus. Rapid freeze-quenched time-resolved EPR revealed that during turnover the intensity of a Mo(V) EPR signal known as High-g [resting] increases. This signal is split by two interacting protons that are not solvent-exchangeable. X-band proton-ENDOR analysis resolved broad symmetrical resonance features that arose from four classes of protons weakly coupled to the Mo(V). Signals from two of these were lost upon exchange into deuterated buffer, suggesting that they may originate from OH(-) or H(2)O groups. One of these signals was also lost when the enzyme was redox-cycled in the presence of azide. Since these protons are very weakly coupled OH/H(2)O groups, they are not likely to be ligated directly to the Mo(V). This suggests that protonation of a Mo(VI)zO group does not occur on reduction to Mo(V), but most probably accompanies reduction of Mo(V) to Mo(IV). A resonance feature from a more strongly coupled proton, that was not lost following exchange into deuterated buffer, could also be resolved at 22-24 MHz. The anisotropy of this feature, determined from ENDOR spectra collected at a range of field positions, indicated a Mo-proton distance of approx. 3.2 A, consistent with this being one of the beta-methylene protons of a Mo-Cys ligand. PMID:11964184

  4. Radioimmunotherapy of nude mice with intraperitoneally growing ovarian cancer xenograft utilizing 211At-labelled monoclonal antibody MOv18.

    PubMed

    Andersson, H; Lindegren, S; Back, T; Jacobsson, L; Leser, G; Horvath, G

    2000-01-01

    The aim of this study was to investigate the therapeutic efficacy of 211At-labelled monoclonal antibody given intraperitoneally to nude mice with intraperitoneal growth of a human ovarian cancer cell line. Female nude mice were inoculated intraperitoneally with 1 x 10(7) cells of the human ovarian cancer cell line NIH:OVCAR 3. After about two weeks they were injected with the 211At-labelled specific monoclonal antibody MOv18 intraperitoneally. For comparison, other groups of mice were given the same labelled antibody intravenously, 211At-labelled unspecific antibody C242 intraperitoneally or unalbelled MOv18 intraperitoneally. Six weeks later the animals were sacrificed and the occurrence of tumour and ascites was determined. When the mice were treated with 211At-labelled MOv18 intraperitoneally 9 out of 10 were apparently free of both ascites and tumour compared to none of the mice given unlabelled antibody. 211At-labelled MOv18 given intravenously or 211At-labelled unspecific antibody given intraperitoneally were less effective. Regional radioimmunotherapy with the alpa-emitter 211Astatine seems to be an effective treatment of nude mice with intraperitoneally growing human ovarian cancer. Hopefully this treatment can be given in an adjuvant setting to women with minimal residual ovarian cancer in the future.

  5. Investigations into Recycling Zinc from Used Metal Oxide Varistors via pH Selective Leaching: Characterization, Leaching, and Residue Analysis

    PubMed Central

    Gutknecht, Toni; Gustafsson, Anna; Forsgren, Christer; Steenari, Britt-Marie

    2015-01-01

    Metal oxide varistors (MOVs) are a type of resistor with significantly nonlinear current-voltage characteristics commonly used in power lines to protect against overvoltages. If a proper recycling plan is developed MOVs can be an excellent source of secondary zinc because they contain over 90 weight percent zinc oxide. The oxides of antimony, bismuth, and to a lesser degree cobalt, manganese, and nickel are also present in varistors. Characterization of the MOV showed that cobalt, nickel, and manganese were not present in the varistor material at concentrations greater than one weight percent. This investigation determined whether a pH selective dissolution (leaching) process can be utilized as a starting point for hydrometallurgical recycling of the zinc in MOVs. This investigation showed it was possible to selectively leach zinc from the MOV without coleaching of bismuth and antimony by selecting a suitable pH, mainly higher than 3 for acids investigated. It was not possible to leach zinc without coleaching of manganese, cobalt, and nickel. It can be concluded from results obtained with the acids used, acetic, hydrochloric, nitric, and sulfuric, that sulfate leaching produced the most desirable results with respect to zinc leaching and it is also used extensively in industrial zinc production. PMID:26421313

  6. Moving standard deviation and moving sum of outliers as quality tools for monitoring analytical precision.

    PubMed

    Liu, Jiakai; Tan, Chin Hon; Badrick, Tony; Loh, Tze Ping

    2018-02-01

    An increase in analytical imprecision (expressed as CV a ) can introduce additional variability (i.e. noise) to the patient results, which poses a challenge to the optimal management of patients. Relatively little work has been done to address the need for continuous monitoring of analytical imprecision. Through numerical simulations, we describe the use of moving standard deviation (movSD) and a recently described moving sum of outlier (movSO) patient results as means for detecting increased analytical imprecision, and compare their performances against internal quality control (QC) and the average of normal (AoN) approaches. The power of detecting an increase in CV a is suboptimal under routine internal QC procedures. The AoN technique almost always had the highest average number of patient results affected before error detection (ANPed), indicating that it had generally the worst capability for detecting an increased CV a . On the other hand, the movSD and movSO approaches were able to detect an increased CV a at significantly lower ANPed, particularly for measurands that displayed a relatively small ratio of biological variation to CV a. CONCLUSION: The movSD and movSO approaches are effective in detecting an increase in CV a for high-risk measurands with small biological variation. Their performance is relatively poor when the biological variation is large. However, the clinical risks of an increase in analytical imprecision is attenuated for these measurands as an increased analytical imprecision will only add marginally to the total variation and less likely to impact on the clinical care. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  7. Experiments of a 100 kV-level pulse generator based on metal-oxide varistor

    NASA Astrophysics Data System (ADS)

    Cui, Yan-cheng; Wu, Qi-lin; Yang, Han-wu; Gao, Jing-ming; Li, Song; Shi, Cheng-yu

    2018-03-01

    This paper introduces the development and experiments of a 100 kV-level pulse generator based on a metal-oxide varistor (MOV). MOV has a high energy handling capacity and nonlinear voltage-current (V-I) characteristics, which makes it useful for high voltage pulse shaping. Circuit simulations based on the measured voltage-current characteristics of MOV verified the shaping concept and showed that a circuit containing a two-section pulse forming network (PFN) will result in better defined square pulse than a simple L-C discharging circuit. A reduced-scale experiment was carried out and the result agreed well with simulation prediction. Then a 100 kV-level pulse generator with multiple MOVs in a stack and a two-section pulse forming network (PFN) was experimented. A pulse with a voltage amplitude of 90 kV, rise time of about 50 ns, pulse width of 500 ns, and flat top of about 400 ns was obtained with a water dummy load of 50 Ω. The results reveal that the combination of PFN and MOV is a practical way to generate high voltage pulses with better flat top waveforms, and the load voltage is stable even if the load's impedance varies. Such pulse generator can be applied in many fields such as surface treatment, corona plasma generation, industrial dedusting, and medical disinfection.

  8. Effect of laser absorption on picosecond laser ablation of Cr12MoV mold steel, 9Cr18 stainless steel and H13A cemented carbide

    NASA Astrophysics Data System (ADS)

    Wu, Baoye; Liu, Peng; Wang, Xizhao; Zhang, Fei; Deng, Leimin; Duan, Jun; Zeng, Xiaoyan

    2018-05-01

    Due to excellent properties, Cr12MoV mold steel, 9Cr18 stainless steel and H13A cemented carbide are widely used in industry. In this paper, the effect of absorption of laser light on ablation efficiency and roughness have been studied using a picosecond pulse Nd:YVO4 laser. The experimental results reveal that laser wavelength, original surface roughness and chemical composition play an important role in controlling ablation efficiency and roughness. Firstly, higher ablation efficiency with lower surface roughness is achieved on the ablation of 9Cr18 at 532, comparing with 1064 nm. Secondly, the ablation efficiency increases while the Ra of the ablated region decreases with the decrease of original surface roughness on ablation of Cr12MoV mold steel at 532 nm. Thirdly, the ablation efficiency of H13A cemented carbide is much higher than 9Cr18 stainless steel and Cr12MoV mold steel at 1064 nm. Scanning electron microscopy images reveals the formation of pores on the surface of 9Cr18 stainless steel and Cr12MoV mold steel at 532 nm while no pores are formed at 1064 nm. As to H13A cemented carbide, worm-like structure is formed at 1064 nm. The synergetic effects of the heat accumulation, plasma shielding and ablation threshold on laser ablation efficiency and machining quality were analyzed and discussed systematically in this paper.

  9. Real time measurements of surface growth evolution in magnetron sputtered single crystal Mo/V superlattices using in situ reflection high energy electron diffraction analysis

    NASA Astrophysics Data System (ADS)

    Svedberg, E. B.; Birch, J.; Edvardsson, C. N. L.; Sundgren, J.-E.

    1999-07-01

    The use of video recording of reflection high energy electron diffraction (RHEED) patterns for assessing the dynamic evolution of the surface morphology and crystallinity during growth was evaluated. As an example, Mo/V(001) superlattices with varying layer thickness (with periods Λ of 2.5 to 8.9 nm and a constant Mo:V ratio of 1:1) were examined. During the deposition, changes from two- to three-dimensional growth were observed in situ. From prior transmission electron microscopy (TEM) and X-ray diffraction (XRD) studies, it is known that this transition is associated with a critical thickness and concurrent roughening of the V layer. Video recording and subsequent image and data processing allowed the surface morphology to be continuously followed during growth. Post-growth analyses of the recorded data provided the evolution of surface lattice parameters and short range [1-2 monolayer (ML)] surface roughnesses with a time resolution of 200-400 ms (0.02-0.04 nm thickness resolution). During growth of Mo, a smoothening effect could be observed while the growth of V evidently increased the surface roughness from 1 to 2 ML. Furthermore, the onset of coherency strain relaxation of the topmost growing layers was observed to occur at 2.0-2.5 nm layer thicknesses for both materials, which is in qualitative agreement with theoretical predictions.

  10. Basaltic material in the main belt: a tale of two (or more) parent bodies?

    NASA Astrophysics Data System (ADS)

    Ieva, S.; Dotto, E.; Lazzaro, D.; Fulvio, D.; Perna, D.; Epifani, E. Mazzotta; Medeiros, H.; Fulchignoni, M.

    2018-06-01

    The majority of basaltic objects in the main belt are dynamically connected to Vesta, the largest differentiated asteroid known. Others, due to their current orbital parameters, cannot be easily dynamically linked to Vesta. This is particularly true for all the basaltic asteroids located beyond 2.5 au, where lies the 3:1 mean motion resonance with Jupiter. In order to investigate the presence of other V-type asteroids in the middle and outer main belt (MOVs) we started an observational campaign to spectroscopically characterize in the visible range MOV candidates. We observed 18 basaltic candidates from TNG and ESO - NTT between 2015 and 2016. We derived spectral parameters using the same approach adopted in our recent statistical analysis and we compared our data with orbital parameters to look for possible clusters of MOVs in the main belt, symptomatic for a new basaltic family. Our analysis seemed to point out that MOVs show different spectral parameters respect to other basaltic bodies in the main belt, which could account for a diverse mineralogy than Vesta; moreover, some of them belong to the Eos family, suggesting the possibility of another basaltic progenitor. This could have strong repercussions on the temperature gradient present in the early Solar System, and on our current understanding of differentiation processes.

  11. Genetic characterization of bank vole virus (BaVV), a new paramyxovirus isolated from kidneys of bank voles in Russia.

    PubMed

    Alkhovsky, Sergey; Butenko, Alexander; Eremyan, Aykaz; Shchetinin, Alexey

    2018-03-01

    A genome of bank vole virus (BaVV), isolated from kidney tissues of bank voles (Myodes glareolus) in Russia in 1973, was sequenced. The genomic organization of BaVV (3'-N-P/V/C-M-F-G-L-5', 16,992 nt in length; GenBank accession number MF943130) is most similar to that of Mossman virus (MoV) and Nariva virus (NarPV), two ungrouped paramyxoviruses isolated from rodents in Australia and Trinidad, respectively. The proteins of BaVV have the highest level of sequence identity (ranging from 23-28% for G protein to 66-73% for M protein) to proteins of MoV and NarPV. The results of genetic and phylogenetic analysis suggest that BaVV represents a new species and, together with MoV and NarPV, belongs to a new, yet not established genus of the family Paramyxoviridae.

  12. Pain in chemotherapy-induced neuropathy--more than neuropathic?

    PubMed

    Geber, Christian; Breimhorst, Markus; Burbach, Berenike; Egenolf, Christina; Baier, Bernhard; Fechir, Marcel; Koerber, Juergen; Treede, Rolf-Detlef; Vogt, Thomas; Birklein, Frank

    2013-12-01

    Chemotherapy-induced neuropathy (CIN) is an adverse effect of chemotherapy. Pain in CIN might comprise neuropathic and nonneuropathic (ie, musculoskeletal) pain components, which might be characterized by pain patterns, electrophysiology, and somatosensory profiling. Included were 146 patients (100 female, 46 male; aged 56 ± 0.8 years) with CIN arising from different chemotherapy regimens. Patients were characterized clinically through nerve conduction studies (NCS) and quantitative sensory testing (QST). Questionnaires for pain (McGill) and anxiety/depression (Hospital Anxiety and Depression Scale) were supplied. Patients were followed-up after 17 days. Large- (61%) and mixed- (35%) fibre neuropathies were more frequent than small-fibre neuropathy (1.4%). The 5 major chemotherapeutic regimens impacted differently on large- but not on small-fibre function and did not predict painfulness. Chronic pain associated with CIN was reported in 41.7%. Painless and painful CIN did not differ in QST profiles or electrophysiological findings, but different somatosensory patterns were found in CIN subgroups (pain at rest [RestP], n = 25; movement-associated pain [MovP], n = 15; both pain characteristics [MovP+RestP], n = 21; or no pain [NonP], n = 85): small-fibre function (cold-detection threshold, CDT: z score: -1.46 ± 0.21, P < 0.01) was most impaired in RestP; mechanical hyperalgesia was exclusively found in MovP (z score: +0.81 ± 0.30, P < 0.05). "Anxiety" discriminated between painful and painless CIN; "CDT" and "anxiety" discriminated between patients with ongoing (RestP) and movement-associated pain (MovP) or pain components (MovP+RestP). The detrimental effect of chemotherapy on large fibres failed to differentiate painful from painless CIN. Patients stratified for musculoskeletal or neuropathic pain, however, differed in psychological and somatosensory parameters. This stratification might allow for the application of a more specific therapy. Copyright © 2013 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.

  13. Low-Cycle Fatigue Behavior of 10CrNi3MoV High Strength Steel and Its Undermatched Welds

    PubMed Central

    Liu, Xuesong; Berto, Filippo

    2018-01-01

    The use of high strength steel allows the design of lighter, more slender and simpler structures due to high strength and favorable ductility. Nevertheless, the increase of yield strength does not guarantee the corresponding improvement of fatigue resistance, which becomes a major concern for engineering structure design, especially for the welded joints. The paper presents a comparison of the low cycle fatigue behaviors between 10CrNi3MoV high strength steel and its undermatched weldments. Uniaxial tension tests, Push-pull, strain-controlled fatigue tests were conducted on base metal and weldments in the strain range of 0.2–1.2%. The monotonic and cyclic stress-strain curves, stress-life, strain-life and energy-life in terms of these materials were analyzed for fatigue assessment of materials discrepancy. The stress-life results of base metal and undermatched weld metal exhibit cyclic softening behaviors. Furthermore, the shapes of 10CrNi3MoV steel hysteresis loops show a satisfactory Masing-type behavior, while the weld metal shows a non-Masing type behavior. Strain, plastic and total strain energy density amplitudes against the number of reversals to failure results demonstrate that the undermatched weld metal presents a higher resistance to fatigue crack initiation than 10CrNi3MoV high strength steel. Finally, fatigue fracture surfaces of specimens were compared by scanning electron microscopy to identify the differences of crack initiation and the propagation between them. PMID:29695140

  14. Low-Cycle Fatigue Behavior of 10CrNi3MoV High Strength Steel and Its Undermatched Welds.

    PubMed

    Song, Wei; Liu, Xuesong; Berto, Filippo; Razavi, S M J

    2018-04-24

    The use of high strength steel allows the design of lighter, more slender and simpler structures due to high strength and favorable ductility. Nevertheless, the increase of yield strength does not guarantee the corresponding improvement of fatigue resistance, which becomes a major concern for engineering structure design, especially for the welded joints. The paper presents a comparison of the low cycle fatigue behaviors between 10CrNi3MoV high strength steel and its undermatched weldments. Uniaxial tension tests, Push-pull, strain-controlled fatigue tests were conducted on base metal and weldments in the strain range of 0.2⁻1.2%. The monotonic and cyclic stress-strain curves, stress-life, strain-life and energy-life in terms of these materials were analyzed for fatigue assessment of materials discrepancy. The stress-life results of base metal and undermatched weld metal exhibit cyclic softening behaviors. Furthermore, the shapes of 10CrNi3MoV steel hysteresis loops show a satisfactory Masing-type behavior, while the weld metal shows a non-Masing type behavior. Strain, plastic and total strain energy density amplitudes against the number of reversals to failure results demonstrate that the undermatched weld metal presents a higher resistance to fatigue crack initiation than 10CrNi3MoV high strength steel. Finally, fatigue fracture surfaces of specimens were compared by scanning electron microscopy to identify the differences of crack initiation and the propagation between them.

  15. Optimal quality (131)I-monoclonal antibodies on high-dose labeling in a large reaction volume and temporarily coating the antibody with IODO-GEN.

    PubMed

    Visser, G W; Klok, R P; Gebbinck, J W; ter Linden, T; van Dongen, G A; Molthoff, C F

    2001-03-01

    A novel, facile procedure for efficient coupling of high doses of (131)I to monoclonal antibodies (MAbs) was developed with minimal chemical and radiation damage. To diminish the radiation and chemical burden during labeling, iodination was performed in a large reaction volume and by temporarily coating the MAb with a minimal amount of IODO-GEN. The MAb was coated by injection of IODO-GEN (dissolved in acetonitrile [MeCN]) into the aqueous MAb solution, and the coating was subsequently removed by addition of ascorbic acid. For chemoprotection before, during, and after PD-10 purification of the (131)I-MAbs, ascorbic acid and human serum albumin were used. The effects of autoradiolysis in the starting (131)I solution were countered by treatment with NaOH and ascorbic acid. For this so-called IODO-GEN-coated MAb method, the sensitive chimeric MAb MOv18 (c-MOv18) and the more robust murine MAbs K928 and E48 were used. The high-dose (131)I-labeled MAbs were characterized for radiochemical purity and MAb integrity by thin-layer chromatography, high-performance liquid chromatography, and sodium dodecyl sulfate polyacrylamide gel electrophoresis followed by phosphor imager quantification. The high-dose (131)I-labeled MAbs were also characterized for immunoreactivity. The radiopharmacokinetics and biodistribution of (131)I-c-MOv18 were analyzed in human tumor-bearing nude mice. For comparison, (131)I-c-MOv18 batches were made using the conventional chloramine-T or IODO-GEN-coated vial method. Conventional high-dose labeling of 5 mg c-MOv18 with 4.4 GBq (131)I resulted in a labeling yield of 60%, a radiochemical purity of 90%, an immunoreactive fraction of 25% (72% being the maximum in the assay used), and the presence of aggregation and degradation products. Using similar amounts of (131)I and MAb in the IODO-GEN-coated MAb method, 85%-89% overall radiochemical yield, at least 99.7% radiochemical purity, and full preservation of MAb integrity and immunoreactivity were achieved. For this labeling, 5 mg MAb were coated with 35 microg IODO-GEN during 3 min in a reaction volume of 6 mL. Also, biodistribution was optimal, and tumor accumulation was superior to that of coinjected (125)I-c-MOv18 labeled according to the conventional IODO-GEN-coated vial method. A new, facile, high-dose (131)I-labeling method was developed for production of (131)I-labeled MAbs with optimal quality for use in clinical radioimmunotherapy.

  16. Assembly of a basket-like {Sr ⊂ P6Mo18O73} cage from 0D dimmer to 2D network and its photo-/electro-catalytic properties.

    PubMed

    Zhang, He; Lv, Jing-Hua; Yu, Kai; Wang, Chun-mei; Wang, Chun-xiao; Sun, Di; Zhou, Bai-bin

    2015-07-28

    A series of basket-like heteropoly blues, formulated as (H4bth)[{Cu(H2O)}2{Sr ⊂ P6MoV2MoVI16O73}]·4H2O (1), {H2bih}3[{FeII(H2O)2}{Sr ⊂ P6MoV2MoVI16O73}]·2H2O (2), (H2bih)3[{CoII(H2O)2}{Sr ⊂ P6MoV2MoVI16O73}]·2H2O (3), (H2bih)3[{NiII(H2O)2}{Sr ⊂ P6MoV2MoVI16O73}]·2H2O (4), (H2bih)2(H2bip)[{Zn (H2O)0.5}{Sr ⊂ P6MoV2MoVI16O73}]·5.5H2O (5), (bth = 1,6-bis(triazole)hexane; bih = 1,6-bis(imidazol)hexane; bip = 1,5-bis(imidazol)pentane) have been synthesized hydrothermally and fully characterized. The structural analysis shows that all the compounds contain two electron reduced polyanions [Sr ⊂ P6MoV2MoVI16O73]8− (abbreviated as {P6Mo18O73}), which consists of a tetra vacant γ-Dawson-type{P2Mo14} unit and a “handle”-shaped {P4Mo4} segment encapsulating a Sr2+ cation in the central cavity. Compound 1 is a 6-connected two-dimensional (2D) layer, which represents the first 2D assembly of basket-type polyoxometalates. Compounds 2–4 are isostructural one-dimensional zigzag chains linked by an M(H2O)2 linker (M = iron for 2, cobalt for 3, and nickel for 4). Compound 5 is a dimeric cluster supported by a binuclear {Zn2(H2O)} unit. The optical band gaps of 1–5 reveal their semiconductive natures. The compounds if used as photocatalysts exhibit a universal high efficiency degradation ability for dyes such as methylene blue, Rhodamine B, and Azon phloxine. The lifetime and reaction mechanism of the catalysts were investigated with a series of experiments. The compounds also show good bifunctional electrocatalytic behavior for the oxidation of ascorbic acid (AA) and reduction of nitrite ions.

  17. Equilibrium Noise in Ion Selective Field Effect Transistors.

    DTIC Science & Technology

    1982-07-21

    face. These parameters have been evaluated for several ion-selective membranes. DD I JAN ") 1473 EDITION or I Mov 09SIS OSSOLETE ONi 0102-LF-0146601...the "integrated circuit" noise on the processing parameters which were different for the two laboratories. This variability in the "integrated circuit...systems and is useful in the identification of the parameters limiting the performance of -11- these systems. In thermodynamic equilibrium, every

  18. Missed detection of significant positive and negative shifts in gentamicin assay: implications for routine laboratory quality practices.

    PubMed

    Koerbin, Gus; Liu, Jiakai; Eigenstetter, Alex; Tan, Chin Hon; Badrick, Tony; Loh, Tze Ping

    2018-02-15

    A product recall was issued for the Roche/Hitachi Cobas Gentamicin II assays on 25 th May 2016 in Australia, after a 15 - 20% positive analytical shift was discovered. Laboratories were advised to employ the Thermo Fisher Gentamicin assay as an alternative. Following the reintroduction of the revised assay on 12 th September 2016, a second reagent recall was made on 20 th March 2017 after the discovery of a 20% negative analytical shift due to erroneous instrument adjustment factor. The practices of an index laboratory were examined to determine how the analytical shifts evaded detection by routine internal quality control (IQC) and external quality assurance (EQA) systems. The ability of the patient result-based approaches, including moving average (MovAvg) and moving sum of outliers (MovSO) approaches in detecting these shifts were examined. Internal quality control data of the index laboratory were acceptable prior to the product recall. The practice of adjusting IQC target following a change in assay method resulted in the missed negative shift when the revised Roche assay was reintroduced. While the EQA data of the Roche subgroup showed clear negative bias relative to other laboratory methods, the results were considered as possible 'matrix effect'. The MovAvg method detected the positive shift before the product recall. The MovSO did not detect the negative shift in the index laboratory but did so in another laboratory 5 days before the second product recall. There are gaps in current laboratory quality practices that leave room for analytical errors to evade detection.

  19. s8ORF2 protein of infectious salmon anaemia virus is a RNA-silencing suppressor and interacts with Salmon salar Mov10 (SsMov10) of the host RNAi machinery.

    PubMed

    Thukral, Vandana; Varshney, Bhavna; Ramly, Rimatulhana B; Ponia, Sanket S; Mishra, Sumona Karjee; Olsen, Christel M; Banerjea, Akhil C; Mukherjee, Sunil K; Zaidi, Rana; Rimstad, Espen; Lal, Sunil K

    2018-04-01

    The infectious salmon anaemia virus (ISAV) is a piscine virus, a member of Orthomyxoviridae family. It encodes at least 10 proteins from eight negative-strand RNA segments. Since ISAV belongs to the same virus family as Influenza A virus, with similarities in protein functions, they may hence be characterised by analogy. Like NS1 protein of Influenza A virus, s8ORF2 of ISAV is implicated in interferon antagonism and RNA-binding functions. In this study, we investigated the role of s8ORF2 in RNAi suppression in a well-established Agrobacterium transient suppression assay in stably silenced transgenic Nicotiana xanthi. In addition, s8ORF2 was identified as a novel interactor with SsMov10, a key molecule responsible for RISC assembly and maturation in the RNAi pathway. This study thus sheds light on a novel route undertaken by viral proteins in promoting viral growth, using the host RNAi machinery.

  20. Towards a Formal Model of the X86 ISA

    DTIC Science & Technology

    2012-03-30

    implies (and (natp i) (natp j) (< i *2^27*)) 101 (equal (nth i (nth *mem-tablei* (initialize-mem-table j x86-64))) (if (<= j i) 1 (nth i (nth *mem...for a MOV instruction ; targeting a GPR ; see Intel 2.2.1.5, p. 2-14, and see AMD Vol. 3 Sec. 1.6 ; (p. 24), which restricts 64-bit immediates to "MOV...instructions that load ; GPRs ". And see AMD Vol. 1 Sec. 3.2.3.3 ("Immediate Operand Size"), which ; specifies those opcodes as "B8h through BFh

  1. Effect of ion-beam treatment on structure and fracture resistance of 12Cr1MoV steel under static, cyclic and dynamic loading

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Panin, S. V., E-mail: svp@ispms.tsc.ru; Vlasov, I. V., E-mail: good0@yandex.ru; Sergeev, V. P., E-mail: retc@ispms.tsc.ru

    2015-10-27

    Features of the structure and properties modification of 12Cr1MoV steel subjected to irradiation by zirconium ion beam have been investigated with the use of optical and electron microscopy as well as microhardness measurement. It has been shown that upon treatment the structure modification occurred across the entire cross-section of specimens with the thickness of 1 mm. Changes in the mechanical properties of these specimens under static, cyclic and impact loading are interpreted in terms of identified structure changes.

  2. Quality of milk and of Canestrato Pugliese cheese from ewes exposed to different ventilation regimens.

    PubMed

    Albenzio, Marzia; Marino, Rosaria; Caroprese, Mariangela; Santillo, Antonella; Annicchiarico, Giovanni; Sevi, Agostino

    2004-11-01

    Effects of ventilation regimen on the quality of ewes' milk and on proteolysis in Canestrato Pugliese cheese during ripening were studied. Cheeses were manufactured from the bulk milk of Comisana ewes subjected to three different ventilation regimens, which were designated low (LOV, 23 m3/h per ewe), moderate (MOV, 47 m3/h per ewe) and programmed ventilation regimen (PROV, 73 m3/h per ewe; fan set to maintain 70% relative humidity). Bulk milk was analysed for chemical and microbial composition, renneting parameters and plasmin-plasminogen activities. At 1, 15, 30 and 45 d of ripening, the cheeses were analysed for gross chemical composition, nitrogen fractions, and plasmin and plasminogen activities. The pH 4.6-insoluble nitrogen fractions were analysed by urea-PAGE. Free amino acid content was determined at the end of ripening. Lower concentrations of bulk milk somatic cell count (BMSCC) and of mesophilic bacteria were found in the MOV group than in the LOV and the PROV groups. A lower plasminogen (PG) to plasmin (PL) ratio (PG/PL) was observed in the MOV and PROV than in the LOV cheeses. Irrespective of treatment, PL activity in cheeses was higher at 15d of ripening, while a sudden decrease of PL and PG activities was observed at 30 d, which was associated with a marked increase in non-protein nitrogen. The peptide profile characterized in the urea-PAGE showed a greater intensity of alpha- and beta-CN hydrolysis in the MOV than in the PROV and LOV cheeses. The results provide evidence that a proper ventilation regimen is critical for optimizing the hygienic quality of milk and the proteolysis of Canestrato Pugliese cheese during ripening.

  3. Tensile Properties of 17-7 PH and 12 MoV Stainless-Steel Sheet under Rapid-Heating and Constant-Temperature Conditions

    NASA Technical Reports Server (NTRS)

    Manning, Charles R., Jr.; Price, Howard L.

    1961-01-01

    Results are presented of rapid-heating tests of 17-7 PH and 12 MoV stainless-steel sheet heated to failure at temperature rates from about 1 F to 170 F per second under constant-load conditions. Yield and rupture strengths obtained from rapid-heating tests are compared with yield and tensile strengths obtained from short-time elevated-temperature tensile tests (30-minute exposure). A rate-temperature parameter was used to construct master curves from which yield and rupture stresses or temperatures can be predicted. A method for measuring strain by optical means is described.

  4. Main Oxidizer Valve Design

    NASA Technical Reports Server (NTRS)

    Addona, Brad; Eddleman, David

    2015-01-01

    A developmental Main Oxidizer Valve (MOV) was designed by NASA-MSFC using additive manufacturing processes. The MOV is a pneumatically actuated poppet valve to control the flow of liquid oxygen to an engine's injector. A compression spring is used to return the valve to the closed state when pneumatic pressure is removed from the valve. The valve internal parts are cylindrical in shape, which lends itself to traditional lathe and milling operations. However, the valve body represents a complicated shape and contains the majority of the mass of the valve. Additive manufacturing techniques were used to produce a part that optimized mass and allowed for design features not practical with traditional machining processes.

  5. Consensus structures of the Mo(v) sites of sulfite-oxidizing enzymes derived from variable frequency pulsed EPR spectroscopy, isotopic labelling and DFT calculations.

    PubMed

    Enemark, John H

    2017-10-10

    Sulfite-oxidizing enzymes from eukaryotes and prokaryotes have five-coordinate distorted square-pyramidal coordination about the molybdenum atom. The paramagnetic Mo(v) state is easily generated, and over the years four distinct CW EPR spectra have been identified, depending upon enzyme source and the reaction conditions, namely high and low pH (hpH and lpH), phosphate inhibited (P i ) and sulfite (or blocked). Extensive studies of these paramagnetic forms of sulfite-oxidizing enzymes using variable frequency pulsed electron spin echo (ESE) spectroscopy, isotopic labeling and density functional theory (DFT) calculations have led to the consensus structures that are described here. Errors in some of the previously proposed structures are corrected.

  6. Can the Functional Movement Screen™ be used to capture changes in spine and knee motion control following 12 weeks of training?

    PubMed

    Frost, David M; Beach, Tyson A C; Campbell, Troy L; Callaghan, Jack P; McGill, Stuart M

    2017-01-01

    To examine whether objective measures of spine and frontal plane knee motion exhibited during Functional Movement Screen™ (FMS) task performance changed following a movement-guided fitness (MOV) and conventional fitness (FIT) exercise intervention. Secondary analysis of a randomized controlled experiment. Before and after 12 weeks of exercise, participants' kinematics were quantified while performing the FMS and a series of general whole-body movement tasks. Biomechanics laboratory. Fifty-two firefighters were assigned to MOV, FIT, or a control (CON) group. Peak lumbar spine flexion/extension, lateral bend and axial twist, and frontal plane knee motion. The post-training kinematic changes exhibited by trainees while performing the FMS tasks were similar in magnitude (effect size < 0.8) to those exhibited by CON. However, when performing the battery of general whole-body movement tasks, only MOV showed significant improvements in spine and frontal plane knee motion control (effect size > 0.5). Whether graded qualitatively, or quantitatively via kinematic analyses, the FMS may not be a viable tool to detect movement-based exercise adaptations. Amendments to the FMS tasks and/or scoring method are needed before it can be used for reasons beyond appraising the ability to move freely, symmetrically, and without pain. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Keplerate cluster (Mo-132) mediated electrostatic assembly of nanoparticles.

    PubMed

    Gooch, Jonathan; Jalan, Abhishek A; Jones, Stephanie; Hine, Corey R; Alam, Rabeka; Garai, Somenath; Maye, Mathew M; Müller, Achim; Zubieta, Jon

    2014-10-15

    The electrostatic assembly between a series of differently charged Mo-132-type Keplerates present in the compounds (NH4)42[{(Mo(VI))Mo(VI)5O21(H2O)6}12 {Mo(V)2O4(CH3COO)}30].ca. {300 H2O+10 CH3COONH4} (Mo-132a), (NH4)72-n[{(H2O)81-n+(NH4)n} {(Mo(VI))Mo(VI)5O21(H2O)6}12 {Mo(V)2O4(SO4)}30].ca. 200 H2O (Mo-132b), and Na10(NH4)62[{(Mo(VI))Mo(VI)5O21(H2O)6}12 {Mo(V)2O4(HPO4)}30]. ca. {300H2O+2Na(+)+2NH4(+)+4H2PO4(-)} (Mo-132c) with cationic gold nanoparticles (AuNPs) was investigated for the first time. The rapid electrostatic assembly from nanoscopic entities to micron scale aggregates was observed upon precipitation, which closely matched the point of aggregate electroneutrality. Successful assembly was demonstrated using UV-vis, DLS, TEM, and zeta-potential analysis. Results indicate that the point at which precipitation occurs is related to charge balance or electroneutrality, and that counterions at both the Mo-132 and AuNP play a significant role in assembly. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Effect of parameters on picosecond laser ablation of Cr12MoV cold work mold steel

    NASA Astrophysics Data System (ADS)

    Wu, Baoye; Liu, Peng; Zhang, Fei; Duan, Jun; Wang, Xizhao; Zeng, Xiaoyan

    2018-01-01

    Cr12MoV cold work mold steel, which is a difficult-to-machining material, is widely used in the mold and dye industry. A picosecond pulse Nd:YVO4 laser at 1064 nm was used to conduct the study. Effects of operation parameters (i.e., laser fluence, scanning speed, hatched space and number of scans) were studied on ablation depth and quality of Cr12MoV at the repetition rate of 20 MHz. The experimental results reveal that all the four parameters affect the ablation depth significantly. While the surface roughness depends mainly on laser fluence or scanning speed and secondarily on hatched space or number of scans. For laser fluence and scanning speed, three distinct surface morphologies were observed experiencing transition from flat (Ra < 1.40 μm) to bumpy (Ra = 1.40 - 2.40 μm) eventually to rough (Ra > 2.40 μm). However, for hatched space and number of scan, there is a small bumpy and rough zone or even no rough zone. Mechanisms including heat accumulation, plasma shielding and combustion reaction effects are proposed based on the ablation depth and processing morphology. By appropriate management of the laser fluence and scanning speed, high ablation depth with low surface roughness can be obtained at small hatched space and high number of scans.

  9. Rapid detection of pandemic influenza in the presence of seasonal influenza

    PubMed Central

    2010-01-01

    Background Key to the control of pandemic influenza are surveillance systems that raise alarms rapidly and sensitively. In addition, they must minimise false alarms during a normal influenza season. We develop a method that uses historical syndromic influenza data from the existing surveillance system 'SERVIS' (Scottish Enhanced Respiratory Virus Infection Surveillance) for influenza-like illness (ILI) in Scotland. Methods We develop an algorithm based on the weekly case ratio (WCR) of reported ILI cases to generate an alarm for pandemic influenza. From the seasonal influenza data from 13 Scottish health boards, we estimate the joint probability distribution of the country-level WCR and the number of health boards showing synchronous increases in reported influenza cases over the previous week. Pandemic cases are sampled with various case reporting rates from simulated pandemic influenza infections and overlaid with seasonal SERVIS data from 2001 to 2007. Using this combined time series we test our method for speed of detection, sensitivity and specificity. Also, the 2008-09 SERVIS ILI cases are used for testing detection performances of the three methods with a real pandemic data. Results We compare our method, based on our simulation study, to the moving-average Cumulative Sums (Mov-Avg Cusum) and ILI rate threshold methods and find it to be more sensitive and rapid. For 1% case reporting and detection specificity of 95%, our method is 100% sensitive and has median detection time (MDT) of 4 weeks while the Mov-Avg Cusum and ILI rate threshold methods are, respectively, 97% and 100% sensitive with MDT of 5 weeks. At 99% specificity, our method remains 100% sensitive with MDT of 5 weeks. Although the threshold method maintains its sensitivity of 100% with MDT of 5 weeks, sensitivity of Mov-Avg Cusum declines to 92% with increased MDT of 6 weeks. For a two-fold decrease in the case reporting rate (0.5%) and 99% specificity, the WCR and threshold methods, respectively, have MDT of 5 and 6 weeks with both having sensitivity close to 100% while the Mov-Avg Cusum method can only manage sensitivity of 77% with MDT of 6 weeks. However, the WCR and Mov-Avg Cusum methods outperform the ILI threshold method by 1 week in retrospective detection of the 2009 pandemic in Scotland. Conclusions While computationally and statistically simple to implement, the WCR algorithm is capable of raising alarms, rapidly and sensitively, for influenza pandemics against a background of seasonal influenza. Although the algorithm was developed using the SERVIS data, it has the capacity to be used at other geographic scales and for different disease systems where buying some early extra time is critical. PMID:21106071

  10. Viewers & Players

    MedlinePlus

    ... Player Play video and audio files on Apple operating systems. mov Apple iTunes Download NLM podcasts and applications. ... Player Play video and audio files on PC operating systems. mp3 wav wmz About MedlinePlus Site Map FAQs ...

  11. Molecular orbital study of some eight-coordinate sulfur chelate complexes of molybdenum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perkins, P.G.; Schultz, F.A.

    1983-03-30

    A number of molybdenum complexes involving the formal oxidation states Mo(IV) and Mo(V) have been studied by a self-consistent-field molecular orbital technique. All the complexes were of dodecahedral geometry and had eight sulfurs chelated to the central metal atom. In all, a series of five tetrakis complexes was studied, including the ligands dithiocarbamate (dtc), thioxanthate (txn), 1,1-dicyano-2,2-ethylenedithiolate (i-mnt), 1-cyano-1-carbethoxy-2,2-ethylenedithiolate (ced), and 1,1-dicarbethoxy-2,2-ethylenedithiolate (ded). The 4d orbitals were included on molybdenum, and the empty 3d levels on all sulfur atoms. The results show that the highest occupied molecular orbital in each case has over 90% metal d/sub xy/ character. Further, themore » energy of this orbital is linearly related to the reversible half-wave potentials for Mo(IV) ..-->.. Mo(V) and Mo(V) ..-->.. Mo(VI) oxidations of the complexes. A further irreversible oxidation observed experimentally also is closely related to the calculated energy levels. Relationships between the calculated results and Mo 3d/sub 5///sub 2/ X-ray photoelectron binding energies, EPR parameters, and charge-transfer absorption energies are discussed. Electrochemical and spectroscopic properties of these MoS/sub 8/ complexes can be understood in terms of a manifold of orbital energies that retain approximately constant spacings between one another and that move up or down in absolute energy in response to the charge donated or withdrawn by the ligands.« less

  12. Mo-doped V2O5 hierarchical nanorod/nanoparticle core/shell porous microspheres with improved performance for cathode of lithium-ion battery

    NASA Astrophysics Data System (ADS)

    Yu, Haolin; Zeng, Jianyun; Hao, Wen; Zhou, Peng; Wen, Xiaogang

    2018-05-01

    Mo-doped V2O5 hierarchical nanorod/nanoparticle core/shell porous microspheres (MVHPMs) were prepared via a simple hydrothermal approach using ammonium metavanadate and ammonium molybdate as precursors followed by a thermal annealing process. The samples were characterized by XRD, SEM, TEM, EDS, and XPS carefully; it confirmed that porous microspheres with uniform Mo doping in the V2O5 matrix were obtained, and it contains an inner core self-assembled with 1D nanorods and outer shell consisting of nanoparticles. A plausible growth mechanism of Mo-doped V2O5 (Mo-V2O5) porous microspheres is suggested. The unique microstructure made the Mo-V2O5 hierarchical microspheres a good cathode material for Li-ion battery. The results indicate the synthesized Mo-V2O5 hierarchical microspheres exhibit well-improved electrochemical performance compared to the undoped samples. It delivers a high initial reversible capacity of 282 mAh g-1 at 0.2 C, 208 mAh g-1 at 2 C, and 111 mAh g-1 at 10 C, and it also exhibits good cycling stabilities; a capacity of 144 mAh g-1 is obtained after 200 cycles at 6 C with a capacity retention of > 82%, which is much high than that of pure V2O5 (95 mAh g-1 with a capacity retention of 72%). [Figure not available: see fulltext.

  13. A little adjustment of synthetic strategy led to a new highly repeated heteropolyblue: Structure, characterizations and photocatalytic properties

    NASA Astrophysics Data System (ADS)

    Chen, Wu-Hua; Zhang, Zhu-Sen; Zhao, Jin-Hua; Qiu, Ze-Hai; Yuan, Qiu-Lan; Huang, Tian-Fu; Lin, Xue-Yu; Hu, Zhi-Biao

    2017-06-01

    Hydrothermal synthesis is known as the most efficient method to prepare novel structural polyoxometalate (POM)-based materials, but controlled synthesis of a structure-directing POM is always challenging task. The experimental repeatability is usually one of the key topics. To explore a reliable hydrothermal synthesis approach for new POMs will be a meaningful work. Our previous work, which we have hydrothermally synthesized the first Cr-complexes-capped Keggin-type POM, [Hdma]3[H2phen]{[Cr(phen)]2[MoV8MoVI4O36(PO4)]}·nH2O (n ≈ 2) (Chen et al., polyhedron, 2015, 85, 117), afford us some commendable synthetic experiences, arouse us some introspections as well for its tricky preparation conditions and low experimental repeatability. Based on the aforementioned work, a new high-repetition-rate and more steady heteropolyblue, [H3O]0.5(Hdma)2.5(dma)0.25{[Cr(phen)]2[MoV6MoVI6O8(PO4)]}·2H2O (1) (dma = dimethylamine (C2H7N), phen = 1,10-phenanthroline (C12H8N2)), has been successfully obtained by virtue of reasonably adjusting synthetic strategy. The adjustment of synthetic strategy includes controlling ratio of reactants and aging time, reasonably using redoxes and stepwise self-assembly plans. Compound 1 is the second POM with Keggin-type polyanion capped by Cr-complexes. Experiments demonstrate that compound 1 has good catalytic activity in the both degradation reactions of rhodamine B (RHB) and methyl orange (MO) under ultraviolet (UV)-light and oxidant H2O2 conditions. Detailed structural characterizations include single-crystal X-ray diffraction (XRD) analyses, energy-dispersive X-ray spectrometry (EDS) analyses, elemental analyses, cerate oxidimetry, powder XRD, fourier transform infrared (FT-IR) spectroscopy, ultraviolet-visible-near-infrared (UV-Vis-NIR) solid diffuse reflection spectrum and X-ray photoelectron spectroscopy (XPS) analyses. The electrochemical property (cyclic voltammetry (CV)) of compound 1 has also been studied.

  14. PANDAS: The Need to Use Definitive Diagnostic Criteria.

    PubMed

    Singer, Harvey S

    2015-01-01

    In Response to: Helm CE, Blackwood RA. Pediatric autoimmune neuropsychiatric disorder associated with streptococcal infections (PANDAS): Experience at a tertiary referral center. Tremor Other Hyperkinet Mov. 2015; 5. doi: 10.7916/D8348JCX.

  15. Alternative Fuels Data Center: Hydrogen Drive

    Science.gov Websites

    , contact Greater Washington Region Clean Cities Coalition. Download QuickTime Video QuickTime (.mov ) Download Windows Media Video Windows Media (.wmv) Video Download Help Text version See more videos provided

  16. Synthesis and high proton conductive performance of a quaternary vanadomolybdotungstosilicic heteropoly acid.

    PubMed

    Cai, Huaxue; Wu, Xuefei; Wu, Qingyin; Yan, Wenfu

    2016-09-28

    A new vanadium and molybdenum-substituted quaternary silicon-containing heteropoly acid H6SiW9MoV2O40·15H2O has been synthesized in this paper by the stepwise acidification and the stepwise addition of elemental solutions. The structural feature and hydration of this product were characterized by IR, UV, XRD and TG-DTA, and its proton conductivity was measured by electrochemical impedance spectroscopy (EIS). The result of EIS shows that H6SiW9MoV2O40·15H2O is a solid high-proton conductor with a conductivity of 6.01 × 10(-3) S cm(-1) at 22 °C and 80% relative humidity, which increases at higher temperatures. Its conductive activation energy is 27.5 kJ mol(-1), which suggests that the mechanism of proton conduction is dominated by the vehicle mechanism.

  17. Catechin concentrates of garden tea leaves (Camellia sinensis L.): extraction/isolation and evaluation of chemical composition.

    PubMed

    Gadkari, Pravin Vasantrao; Kadimi, Udaya Sankar; Balaraman, Manohar

    2014-11-01

    Solid-liquid (SLE) and liquid-liquid (LLE) extraction techniques were applied to extract catechins and caffeine from quick mechanically expelled tea leaf juice (QMETLJ) and freeze-dried (FD)-QMETLJ of Camellia sinensis L. The concentrates obtained were analyzed for total polyphenol content and antioxidant activity (DPPH(•) inhibition, FRAP and phosphomolybdenum assay). Catechins were identified and quantified using HPLC. Overall, 95% (v/v) ethanol was the best solvent system for extracting total polyphenols (355.26 ± 23.68 to 457.89 ± 28.94 g GAE kg(-1) extractable solid yield (ESY)) and antioxidants (DPPH(•) inhibition, 16.97 ± 0.52 to 20.83 ± 3.11%; FRAP, 4.15 ± 0.32 to 6.38 ± 0.57 mmol TE g(-1) ESY; Mo(V) reduction, 2.47 ± 0.19 to 3.84 ± 0.39 mmol AAE g(-1) ESY) from FD-QMETLJ. Similarly, in LLE, ethyl acetate showed the best results for recovering polyphenols (960.52 ± 7.89 g GAE kg(-1) ESY) and antioxidants (DPPH(•) inhibition, 42.39 ± 0.91%; FRAP, 11.39 ± 0.83 mmol TE g(-1) ESY; Mo(V) reduction, 6.71 ± 1.14 mmol AAE g(-1) ESY) from QMETLJ. It was found that 95% ethanol can be used to increase the total polyphenols and antioxidants in extracts from FD-QMETLJ, while ethyl acetate can be effectively employed for concentrating catechins from QMETLJ. © 2014 Society of Chemical Industry.

  18. Automated segmentation of mouse OCT volumes (ASiMOV): Validation & clinical study of a light damage model.

    PubMed

    Antony, Bhavna Josephine; Kim, Byung-Jin; Lang, Andrew; Carass, Aaron; Prince, Jerry L; Zack, Donald J

    2017-01-01

    The use of spectral-domain optical coherence tomography (SD-OCT) is becoming commonplace for the in vivo longitudinal study of murine models of ophthalmic disease. Longitudinal studies, however, generate large quantities of data, the manual analysis of which is very challenging due to the time-consuming nature of generating delineations. Thus, it is of importance that automated algorithms be developed to facilitate accurate and timely analysis of these large datasets. Furthermore, as the models target a variety of diseases, the associated structural changes can also be extremely disparate. For instance, in the light damage (LD) model, which is frequently used to study photoreceptor degeneration, the outer retina appears dramatically different from the normal retina. To address these concerns, we have developed a flexible graph-based algorithm for the automated segmentation of mouse OCT volumes (ASiMOV). This approach incorporates a machine-learning component that can be easily trained for different disease models. To validate ASiMOV, the automated results were compared to manual delineations obtained from three raters on healthy and BALB/cJ mice post LD. It was also used to study a longitudinal LD model, where five control and five LD mice were imaged at four timepoints post LD. The total retinal thickness and the outer retina (comprising the outer nuclear layer, and inner and outer segments of the photoreceptors) were unchanged the day after the LD, but subsequently thinned significantly (p < 0.01). The retinal nerve fiber-ganglion cell complex and the inner plexiform layers, however, remained unchanged for the duration of the study.

  19. Automated segmentation of mouse OCT volumes (ASiMOV): Validation & clinical study of a light damage model

    PubMed Central

    Lang, Andrew; Carass, Aaron; Prince, Jerry L.; Zack, Donald J.

    2017-01-01

    The use of spectral-domain optical coherence tomography (SD-OCT) is becoming commonplace for the in vivo longitudinal study of murine models of ophthalmic disease. Longitudinal studies, however, generate large quantities of data, the manual analysis of which is very challenging due to the time-consuming nature of generating delineations. Thus, it is of importance that automated algorithms be developed to facilitate accurate and timely analysis of these large datasets. Furthermore, as the models target a variety of diseases, the associated structural changes can also be extremely disparate. For instance, in the light damage (LD) model, which is frequently used to study photoreceptor degeneration, the outer retina appears dramatically different from the normal retina. To address these concerns, we have developed a flexible graph-based algorithm for the automated segmentation of mouse OCT volumes (ASiMOV). This approach incorporates a machine-learning component that can be easily trained for different disease models. To validate ASiMOV, the automated results were compared to manual delineations obtained from three raters on healthy and BALB/cJ mice post LD. It was also used to study a longitudinal LD model, where five control and five LD mice were imaged at four timepoints post LD. The total retinal thickness and the outer retina (comprising the outer nuclear layer, and inner and outer segments of the photoreceptors) were unchanged the day after the LD, but subsequently thinned significantly (p < 0.01). The retinal nerve fiber-ganglion cell complex and the inner plexiform layers, however, remained unchanged for the duration of the study. PMID:28817571

  20. Development of a miniaturized optical viscosity sensor with an optical surface tracking system

    NASA Astrophysics Data System (ADS)

    Abe, H.; Nagamachi, R.; Taguchi, Y.; Nagasaka, Y.

    2010-02-01

    A new viscosity sensor enabling non-contact measurement at high speed, with less sample volume and high stability is required in a broad field. For example, in the industrial field, process control by real time monitoring of viscosity can enhance the quality of coating films and the process yield such as conductive films and optical films. Therefore, we have developed a new miniaturized optical viscosity sensor, namely MOVS (Miniaturized Optical Viscosity Sensor), based on a laser-induced capillary wave (LiCW) method which can meet the requirements above. In the MOVS, viscosity is estimated by observing the damping oscillation of LiCW, which is generated by an interference of two excitation laser beams on a liquid surface. By irradiating a probing laser on LiCW, a first order diffracted beam containing information of sample viscosity, is generated. The intensity of the reflected beam is utilized to control the distance between liquid-level and the sensor. The newly integrated optical surface tracking system makes possible the stable viscosity measurement in the presence of disturbance such as evaporation and external vibration. MOVS consists of five U-grooves fabricated by MEMS (Micro Electro Mechanical Systems) process to possess the optical fibers (photonic crystal fibers and fusion-spliced lensed fibers). In this study, by integrating the optical surface tracking system on the chip, nanosecond order damping oscillation of LiCW is successfully observed in the presence of external forced vibration, high speed evaporation (speed of 1 micrometer per second) and drying process of a liquid film (thickness of hundreds micrometer order).

  1. Ghrelin

    USDA-ARS?s Scientific Manuscript database

    The gut hormone ghrelin was discovered in 1999. In the last 15 years, ample data have been generated on ghrelin. Bedsides its hallmark function as an appetite stimulator, ghrelin also has many other important functions. In this review, we discussed ghrelin's functions in learning and memory, gut mov...

  2. An immunologically relevant rodent model demonstrates safety of therapy using a tumour-specific IgE.

    PubMed

    Josephs, Debra H; Nakamura, Mano; Bax, Heather J; Dodev, Tihomir S; Muirhead, Gareth; Saul, Louise; Karagiannis, Panagiotis; Ilieva, Kristina M; Crescioli, Silvia; Gazinska, Patrycja; Woodman, Natalie; Lomardelli, Cristina; Kareemaghay, Sedigeh; Selkirk, Christopher; Lentfer, Heike; Barton, Claire; Canevari, Silvana; Figini, Mariangela; Downes, Noel; Dombrowicz, David; Corrigan, Christopher J; Nestle, Frank O; Jones, Paul S; Gould, Hannah J; Blower, Philip J; Tsoka, Sophia; Spicer, James F; Karagiannis, Sophia N

    2018-04-13

    Designing biologically informative models for assessing the safety of novel agents, especially for cancer immunotherapy, carries substantial challenges. The choice of an in vivo system for studies on IgE antibodies represents a major impediment to their clinical translation, especially with respect to class-specific immunological functions and safety. Fcε receptor expression and structure are different in humans and mice, so that the murine system is not informative when studying human IgE biology. By contrast, FcεRI expression and cellular distribution in rats mirrors that of humans. We are developing MOv18 IgE, a human chimeric antibody recognizing the tumour-associated antigen folate receptor alpha. We created an immunologically congruent surrogate rat model likely to recapitulate human IgE-FcεR interactions, and engineered a surrogate rat IgE equivalent to MOv18. Employing this model, we examined in vivo safety and efficacy of anti-tumour IgE antibodies. In immunocompetent rats, rodent IgE restricted growth of syngeneic tumours in the absence of clinical, histopathological or metabolic signs associated with obvious toxicity. No physiological or immunological evidence of a 'cytokine-storm' or allergic response was seen, even at 50 mg/kg weekly doses. IgE treatment was associated with elevated serum concentrations of TNFα, a mediator previously linked with IgE-mediated anti-tumour and anti-parasitic functions, alongside evidence of substantially elevated tumoural immune cell infiltration and immunological pathway activation in tumour-bearing lungs. Our findings indicate safety of MOv18 IgE, in conjunction with efficacy and immune activation, supporting the translation of this therapeutic approach to the clinical arena. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  3. Immunotherapy in a human ovarian cancer xenograft model with two bispecific monoclonal antibodies: OV-TL 3/CD3 and OC/TR.

    PubMed

    van Ravenswaay Claasen, H H; Eggermont, A M; Nooyen, Y A; Warnaar, S O; Fieuren, G J

    1994-02-01

    The bispecific antibodies (bs-mAbs) OV-TL 3/CD3 and OC/TR (MOv18/CD3) efficiently mediate ovarian tumor cell lysis by cytotoxic T cells and activated peripheral blood lymphocytes (PBL) in vitro. OV-TL 3/CD3 and OC/TR are reactive with tumor-associated antigens on ovarian carcinoma cells (OA3 and CA-MOv18, respectively), and CD3 on activated PBL, bridging both cells and simultaneously inducing activation of the effector cells. In a comparative study we investigated the therapeutic efficacy of OV-TL 3/CD3 and OC/TR by targeting activated PBL with the bs-mAbs against intraperitoneally growing NIH:OVCAR-3 human ovarian carcinoma cells. As they have good tumor localization characteristics, HPLC-purified bispecific F(ab')2 fragments were used to target highly active PHA and IL-2-stimulated PBL effector cells. The efficacy of OV-TL 3/CD3 was compared to OC/TR with respect to tumor-associated antigen (TAA) binding on NIH:OVCAR-3 ascites cells and NIH:OVCAR-3 tumor cell lysis in vitro. In this report we show that ip ovarian cancer-bearing nude mice treated with IL-2 and activated PBL coated with bispecific F(ab')2 had a significantly longer survival than the untreated mice. No significant difference in survival was found between the OC/TR or OV-TL 3/CD3 bispecific antibody, although MOv18 expression was higher on NIH:OVCAR-3 ascites cells and PBL targeted with OC/TR induced slightly higher tumor cell lysis in vitro. Thus, the therapeutic efficacy of these bs-mAbs in vivo could not be predicted by TAA expression or bs-mAb-mediated tumor cell lysis in vitro.

  4. Species of the Mississippi River Headwaters Reservoirs Region.

    DTIC Science & Technology

    1976-07-01

    inventory and analysis system (ERIAS). _ 00, ’<*" 14175 JAM TO WJ COITION OF > MOV «S IS OBSOLETE UNCLASSIFIED SECURITY CLASSIFICATION1 OF THIS...COMMON) SUNFISH, GREEN (SUNFISH), PUMPKIN SEED SWALLOW, BANK SWALLOW, BARN SWALLOW, ROUGH-WINGED SWALLOW, TREE SWAN, WHISTLING SWIFT

  5. Introduction to tillage erosion

    USDA-ARS?s Scientific Manuscript database

    Tillage as a source of erosion Tillage erosion is the downslope movement of soil by tillage. During tillage, soil is lifted and gravity moves soil downslope. Soil movement by tillage increases with slope steepness. However, net soil transport by tillage is determined by the change in slope. Soil mov...

  6. A workflow to process 3D+time microscopy images of developing organisms and reconstruct their cell lineage

    PubMed Central

    Faure, Emmanuel; Savy, Thierry; Rizzi, Barbara; Melani, Camilo; Stašová, Olga; Fabrèges, Dimitri; Špir, Róbert; Hammons, Mark; Čúnderlík, Róbert; Recher, Gaëlle; Lombardot, Benoît; Duloquin, Louise; Colin, Ingrid; Kollár, Jozef; Desnoulez, Sophie; Affaticati, Pierre; Maury, Benoît; Boyreau, Adeline; Nief, Jean-Yves; Calvat, Pascal; Vernier, Philippe; Frain, Monique; Lutfalla, Georges; Kergosien, Yannick; Suret, Pierre; Remešíková, Mariana; Doursat, René; Sarti, Alessandro; Mikula, Karol; Peyriéras, Nadine; Bourgine, Paul

    2016-01-01

    The quantitative and systematic analysis of embryonic cell dynamics from in vivo 3D+time image data sets is a major challenge at the forefront of developmental biology. Despite recent breakthroughs in the microscopy imaging of living systems, producing an accurate cell lineage tree for any developing organism remains a difficult task. We present here the BioEmergences workflow integrating all reconstruction steps from image acquisition and processing to the interactive visualization of reconstructed data. Original mathematical methods and algorithms underlie image filtering, nucleus centre detection, nucleus and membrane segmentation, and cell tracking. They are demonstrated on zebrafish, ascidian and sea urchin embryos with stained nuclei and membranes. Subsequent validation and annotations are carried out using Mov-IT, a custom-made graphical interface. Compared with eight other software tools, our workflow achieved the best lineage score. Delivered in standalone or web service mode, BioEmergences and Mov-IT offer a unique set of tools for in silico experimental embryology. PMID:26912388

  7. Structures and reaction pathways of the molybdenum centres of sulfite-oxidizing enzymes by pulsed EPR spectroscopy.

    PubMed

    Enemark, John H; Astashkin, Andrei V; Raitsimring, Arnold M

    2008-12-01

    SOEs (sulfite-oxidizing enzymes) are physiologically vital and occur in all forms of life. During the catalytic cycle, the five-co-ordinate square pyramidal oxo-molybdenum active site passes through the Mo(V) state, and intimate details of the structure can be obtained from variable frequency pulsed EPR spectroscopy through the hyperfine and nuclear quadrupole interactions of nearby magnetic nuclei. By employing variable spectrometer operational frequencies, it is possible to optimize the measurement conditions for difficult quadrupolar nuclei of interest (e.g. (17)O, (33)S, (35)Cl and (37)Cl) and to simplify the interpretation of the spectra. Isotopically labelled model Mo(V) compounds provide further insight into the electronic and geometric structures and chemical reactions of the enzymes. Recently, blocked forms of SOEs having co-ordinated sulfate, the reaction product, were detected using (33)S (I=3/2) labelling. This blocking of product release is a possible contributor to fatal human sulfite oxidase deficiency in young children.

  8. The effect of RGB monochromatic and polychromatic LED lighting on growth performance, behavior, and development of broilers

    NASA Astrophysics Data System (ADS)

    Morrill, Waldirene B. B.; Barnabé, Janice M. C.; da Silva, Tatiana P. N.; Pandorfi, Héliton; Gouveia-Neto, Artur S.; Souza, Wellington S.

    2014-03-01

    Growth performance, behavior, and development of broilers reared under red, green, and blue monochromatic and/or multicolor LED-based illuminants is investigated. The lighting treatments were performed on a 24h lighting basis during six weeks. Monochromatic red(630 nm), green(520 nm), and blue(460 nm), and simultaneous blue-green, and whitelight housing illumination was employed. Bodyweight, food consumption, and behavior were monitored and compared amongst light treatments. The behavioral data showed that broilers reared under green lighting presented the lowest respiratory rate (87 mov. min-1) while those under red lighting presented the highest (96 mov. min-1). Results also showed that broilers under blue and/or green monochromatic illumination exhibited up to 6%, and 8.9 % increase in final bodyweight when compared to those under red or white-light, respectively. The highest feed intake, and lowest body weight gain was observed in broilers reared under blue and red illumination, respectively.

  9. Statistical Analysis of the LMS and Modified Stochastic Gradient Algorithms

    DTIC Science & Technology

    1989-05-14

    siloare of the input data and incorporated directly Into recurisive descriptions and/or nonuniform weighted mov- the altorithmn ar, a data-dependent time...houlsotaion- are al.~, ii%ed tito rteod the welitht tranotienitwbhav- These results are a measure of how rapidly the algo- lair . The Mrnuation,; aalggeut

  10. Genetics Home Reference: infantile neuroaxonal dystrophy

    MedlinePlus

    ... with brain iron accumulation (NBIA): an update on clinical presentations, histological and genetic underpinnings, and treatment considerations. Mov Disord. 2012 Jan;27(1):42-53. doi: 10.1002/mds.23971. Epub 2011 Oct 26. Review. ... Zhang Y, Xiao J, Wu X. Clinical study and PLA2G6 mutation screening analysis in Chinese ...

  11. Nondestructive analysis of three-dimensional objects using a fluid displacement method

    USDA-ARS?s Scientific Manuscript database

    Quantification of three-dimensional (3-D) objects has been a real challenge in agricultural, hydrological and environmental studies. We designed and tested a method that is capable of quantifying 3-D objects using measurements of fluid displacement. The device consists of a stand that supports a mov...

  12. 76 FR 15814 - Airworthiness Directives; The Boeing Company Model 747 Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-22

    ... listed above. This AD requires measuring the electrical bond resistance between the motor operated valve... SNPRM proposed to require measuring the electrical bond resistance between the motor operated valve (MOV... the relevant data, considered the comment received, and determined that air safety and the public...

  13. Theoretical Analyses of the Functional Regions of the Heavy Chain of Botulinum Neurotoxin

    DTIC Science & Technology

    1994-01-01

    SE. Schulz GM. liallctt M. Effects of hb)tulinum toxin injections on speech in adductor spasmodic dysphonia . Neurology 1988,38:1220-1225. 3. Jankovic...hemifacial spasm. Mov Disord 1987:4:237-254. 5. Brin MF. Blitzer A, Fahn S, Gould W. Lovelace RE. Adductor laryngeal dystonia (spastic dysphonia ): treatment

  14. Alternative Fuels Data Center: Schwan's Home Service Delivers With

    Science.gov Websites

    distribute products across the United States. For information about this project, contact Twin Cities Clean Cities Coalition. Download QuickTime Video QuickTime (.mov) Download Windows Media Video Windows Media (.wmv) Video Download Help Text version See more videos provided by Clean Cities TV and FuelEconomy.gov

  15. The curative and palliative potential of the monoclonal antibody MOv18 labelled with 211At in nude mice with intraperitoneally growing ovarian cancer xenografts--a long-term study.

    PubMed

    Andersson, H; Lindegren, S; Bäck, T; Jacobsson, L; Leser, G; Horvath, G

    2000-01-01

    The purpose of the present study was to investigate the therapeutic efficacy of 211At-labelled specific monoclonal antibody MOv18 in nude mice with intraperitoneal growth of the human ovarian cancer cell line OVCAR3. In the first part of the study the antibody was injected intraperitoneally when the cancer growth was microscopic. The injected activity was 485-555 kBq. The median survival for treated mice was 213 days compared to 138 days for untreated mice (p < 0.014, log-rank test). No obvious toxicity was seen. Thirty-three percent of the mice were apparently free of cancer after 7 months and were probably cured. In the second part of the study mice with macroscopic cancer and signs of ascites were injected intraperitoneally with the same 211At-labelled antibody (377-389 kBq). This treatment possibly delayed the production of ascites. Hopefully radioimmunotherapy with regionally administered 211At-labelled antibody will be of value in women with ovarian cancer as well.

  16. Amplified Rate Acceleration by Simultaneous Up-Regulation of Multiple Active Sites in an Endo-Functionalized Porous Capsule.

    PubMed

    Kopilevich, Sivil; Müller, Achim; Weinstock, Ira A

    2015-10-14

    Using the hydrolysis of epoxides in water as a model reaction, the effect of multiple active sites on Michaelis-Menten compliant rate accelerations in a porous capsule is demonstrated. The capsule is a water-soluble Ih-symmetry Keplerate-type complex of the form, [{Mo(VI)6O21(H2O)6}12{Mo(V)2O4(L)}30](42-), in which 12 pentagonal "ligands," {(Mo(VI))Mo(VI)5O21(H2O)6}(6-), are coordinated to 30 dimolybdenum sites, {Mo(V)2O4L}(1+) (L = an endohedrally coordinated η(2)-bound carboxylate anion), resulting in 20 Mo9O9 pores. When "up-regulated" by removal of ca. one-third of the blocking ligands, L, an equal number of dimolybdenum sites are activated, and the newly freed-up space allows for encapsulation of nearly twice as many substrate guests, leading to a larger effective molarity (amplification), and an increase in the rate acceleration (k(cat)/k(uncat)) from 16,000 to an enzyme-like value of 182,800.

  17. Effect of electroslag remelting on carbides in 8Cr13MoV martensitic stainless steel

    NASA Astrophysics Data System (ADS)

    Zhu, Qin-tian; Li, Jing; Shi, Cheng-bin; Yu, Wen-tao

    2015-11-01

    The effect of electroslag remelting (ESR) on carbides in 8Cr13MoV martensitic stainless steel was experimentally studied. Phases precipitated from liquid steel during solidification were calculated using the Thermo-Calc software. The carbon segregation was analyzed by original position analysis (OPA), and the carbides were analyzed by optical microscopy (OM), scanning electron microscopy (SEM), energy- dispersive X-ray spectroscopy (EDS) and X-ray diffraction (XRD). The results indicated that more uniform carbon distribution and less segregation were obtained in the case of samples subjected to the ESR process. After ESR, the amount of netty carbides decreased significantly, and the chromium and vanadium contents in the grain-boundary carbides was reduced. The total area and average size of carbides were obviously smaller after the ESR process. In the sample subjected to ESR, the morphology of carbides changed from lamellar and angular to globular or lump, whereas the types of carbides did not change; both M23C6 and M7C3 were present before and after the ESR process.

  18. The effect of user experience and inflation technique on endotracheal tube cuff pressure using a feline airway simulator.

    PubMed

    White, Donna M; Redondo, José I; Mair, Alastair R; Martinez-Taboada, Fernando

    2017-09-01

    The effect of user experience and inflation technique on endotracheal tube cuff pressure using a feline airway simulator. Prospective, experimental clinical study. Participants included veterinary students at the beginning (group S1) and end (group S2) of their 2-week anaesthesia rotation and veterinary anaesthetists (group A). The feline airway simulator was designed to simulate an average size feline trachea, intubated with a 4.5 mm low-pressure, high-volume cuffed endotracheal tube, connected to a Bain breathing system with oxygen flow of 2 L minute -1 . Participants inflated the on-endotracheal tube cuff by pilot balloon palpation and by instilling the minimum occlusive volume (MOV) required for loss of airway leaks during manual ventilation. Intracuff pressures were measured by manometers obscured to participants and ideally were 20-30 cm H 2 O. Student t, Fisher exact, and Chi-squared tests were used where appropriate to analyse data (p < 0.05). Participants were 12 students and eight anaesthetists. Measured intracuff pressures for palpation and MOV, respectively, were 19 ± 12 and 29 ± 19 cm H 2 O for group S1, 10 ± 5 and 20 ± 11 cm H 2 O for group S2 and 13 ± 6 and 29 ± 18 cm H 2 O for group A. All groups performed poorly at achieving intracuff pressures within the ideal range. There was no significant difference in intracuff pressures between techniques. Students administered lower (p = 0.02) intracuff pressures using palpation after their training. When using palpation and MOV for cuff inflation operators rarely achieved optimal intracuff pressures. Experience had no effect on this skill and, as such, a cuff manometer is recommended. Copyright © 2017 Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and Analgesia. Published by Elsevier Ltd. All rights reserved.

  19. Incidence of premature estrus in lactating dairy cows and conception rates to standing estrus or fixed-time inseminations after synchronization using GnRH and PGF(2alpha).

    PubMed

    DeJarnette, J M; Salverson, R R; Marshall, C E

    2001-07-03

    Fixed-time AI (TAI) after GnRH-PGF(2alpha)-GnRH treatment is a method to achieve pregnancies in dairy herds without estrous detection. However, cows that fail to respond to the initial GnRH may have compromised TAI conception rates due to asynchronous ovarian response. This study documented the percentage of GnRH-treated Holstein cows (n=345) in two herds that displayed estrus at an inopportune time for optimum TAI conception rate (< or =48h post-PGF(2alpha); premature estrus (PE)) and compared conception rates of two TAI protocols in cows that did not display PE. At biweekly herd health exams, cows diagnosed as not pregnant to a previous AI and cows >80 days postpartum with no AI were treated with 100 microg GnRH (day -7) and 25mg PGF(2alpha) (day 0). Cows detected in PE by twice-daily visual observation from day -7 to day 2 were bred by AI 8-12h later. Cows not detected in PE were randomly assigned by parity, body condition score, and postpartum interval to receive either: (1) 100microg GnRH at 48h after PGF(2alpha) and TAI 16 to 18h later (Ovsynch); or (2) TAI at 72h post-PGF(2alpha) and a concurrent 100 microg GnRH injection to those cows not detected in estrus between 48 and 72h post-PGF(2alpha) (modified Ovsynch (MOV)). All hormone injections were im. Twenty percent (68/345) of the cows were detected in estrus before 48 after PGF(2alpha), of which 5% (17/345) were detected in estrus before PGF(2alpha) (< or =day 0). Herd influenced the percentage of cows in the PE group (herd A versus herd B; 25% versus 14%; P<0.05). Conception rates were not affected by treatment (PE versus Ovsynch versus MOV; 32% (21/65) versus 30% (37/125) versus 32% (47/145); P>0.10). However, within MOV-treated cows, conception rates were greater (P<0.05) in cows detected in estrus (46% (23/50)) compared with cows not detected in estrus (25% (24/95)). In conclusion, 20% of GnRH-treated cows displayed PE and necessitates estrous detection during this period if maximal pregnancy rates are to be achieved. Although additional estrous detection is required compared to Ovsynch, reduced cow handling and hormone usage, efficient use of expensive semen through greater conception rates in cows detected in estrus, and comparable TAI conception rates, suggests the MOV protocol may be a cost effective alternative to Ovsynch in many dairy herd reproductive management programs.

  20. 76 FR 13534 - Airworthiness Directives; The Boeing Company Model 767-200, -300, -300F, and -400ER Series Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-14

    ... certain motor operated valve actuators for the fuel tanks are installed, and related investigative and... additional inspections to determine if certain motor operated valve actuators for the fuel tanks are... requires an inspection to determine if certain motor operated valve (MOV) actuators for the fuel tanks are...

  1. Alternative Fuels Data Center: Maine's Only Biodiesel Manufacturer Powers

    Science.gov Websites

    this project, contact Maine Clean Communities. Download QuickTime Video QuickTime (.mov) Download Windows Media Video Windows Media (.wmv) Video Download Help Text version See more videos provided by truck Krug Energy Opens Natural Gas Fueling Station in Arkansas June 18, 2016 photo of natural gas

  2. Alternative Fuels Data Center: Texas Taxis Go Hybrid

    Science.gov Websites

    information about this project, contact Alamo Area Clean Cities (San Antonio). Download QuickTime Video QuickTime (.mov) Download Windows Media Video Windows Media (.wmv) Video Download Help Text version See more car Hydrogen Powers Fuel Cell Vehicles in California Nov. 18, 2017 Photo of a car Smart Car Shopping

  3. Alternative Fuels Data Center: Kentucky Trucking Company Adds CNG Vehicles

    Science.gov Websites

    run on compressed natural gas (CNG) in Lousiville, Kentucky. Download QuickTime Video QuickTime (.mov California Nov. 18, 2017 Photo of a car Smart Car Shopping Nov. 4, 2017 Photo of a truck Natural Gas Vehicles truck Idaho Transports Mail and Reduces Emissions with Natural Gas Trucks June 23, 2017 Photo of a

  4. Alternative Fuels Data Center: Coca-Cola Continues to Expand Its Heavy-Duty

    Science.gov Websites

    Hybrid Fleet in AtlantaA> Coca-Cola Continues to Expand Its Heavy-Duty Hybrid Fleet in Atlanta to information about this project, contact Clean Cities-Georgia. Download QuickTime Video QuickTime (.mov Provided by Maryland Public Television Related Videos Photo of a car Electric Vehicles Charge up at State

  5. 77 FR 47080 - Announcement of Requirements and Registration for “Stop Bullying Video Challenge”

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-07

    ... must upload their video to YouTube as private. To do this, select ``Privacy Settings,'' mark video as private, enter the YouTube username ``stopbullyinggov'' in the box that appears below, then select ``save changes.'' Videos must be uploaded to YouTube in one of the following file formats: WebM, MPEG4, 3GPP, MOV...

  6. Soil Movement in Established Gullies After A Single Prescribed Burn in the South Carolina Piedmont

    Treesearch

    Charles T. Cushwa; Melvin Hopkins; Burd S. McGinnes

    1971-01-01

    The effect of prescribed burning on soil movement in 25 established gullies was studied on Sumter National Forest, South Carolina. One moderately intense backfire in Piedmont pine communities did not have a measurable effect on soil mov.ement in these gullies. Studies involving the effects of burning on factors other than soil movement are recommended.

  7. Alternative Fuels Data Center: America's Largest Home Runs on Biodiesel in

    Science.gov Websites

    Coalition (Western North Carolina). Download QuickTime Video QuickTime (.mov) Download Windows Media Video Windows Media (.wmv) Video Download Help Text version See more videos provided by Clean Cities TV and Photo of a car Hydrogen Powers Fuel Cell Vehicles in California Nov. 18, 2017 Photo of a car Smart Car

  8. Alternative Fuels Data Center: Rhode Island EV Initiative Adds Chargers

    Science.gov Websites

    Ocean State Clean Cities. Download QuickTime Video QuickTime (.mov) Download Windows Media Video Windows Media (.wmv) Video Download Help Text version See more videos provided by Clean Cities TV and Photo of a car Hydrogen Powers Fuel Cell Vehicles in California Nov. 18, 2017 Photo of a car Smart Car

  9. Alternative Fuels Data Center: Worcester Regional Transit Authority Drives

    Science.gov Websites

    Clean Cities. Download QuickTime Video QuickTime (.mov) Download Windows Media Video Windows Media (.wmv ) Video Download Help Text version See more videos provided by Clean Cities TV and FuelEconomy.gov Fuel Cell Vehicles in California Nov. 18, 2017 Photo of a car Smart Car Shopping Nov. 4, 2017 Image of

  10. Alternative Fuels Data Center: Propane Powers Airport Shuttles in New

    Science.gov Websites

    Clean Fuel Partnership. Download QuickTime Video QuickTime (.mov) Download Windows Media Video Windows Media (.wmv) Video Download Help Text version See more videos provided by Clean Cities TV and Vehicles in California Nov. 18, 2017 Photo of a car Smart Car Shopping Nov. 4, 2017 Photo of a truck

  11. Spectroscopic Characterization of YedY: The Role of Sulfur Coordination in a Mo(V) Sulfite Oxidase Family Enzyme Form

    PubMed Central

    Yang, Jing; Rothery, Richard; Sempombe, Joseph

    2011-01-01

    Electronic paramagnetic resonance, electronic absorption, and magnetic circular dichroism spectroscopies have been performed on YedY, a SUOX fold protein with a Mo domain that is remarkably similar to that found in chicken sulfite oxidase, A. thaliana plant sulfite oxidase, and the bacterial sulfite dehydrogenase from S. novella. Low-energy dithiolene→Mo and cysteine thiolate→Mo charge transfer bands have been assigned for the first time in a Mo(V) form of a SUOX fold protein, and the spectroscopic data have been used to interpret the results of bonding calculations. The analysis shows that second coordination sphere effects modulate dithiolene and cysteine sulfur covalency contributions to the Mo bonding scheme. Namely, a more acute Ooxo-Mo-SCys-C dihedral angle results in increased cysteine thiolate S→Mo charge transfer and a high g1 in the EPR spectrum. The spectrosocopic results, coupled with the available structural data, indicate that these second coordination sphere effects may play key roles in modulating the active site redox potential, facilitating hole superexchange pathways for electron transfer regeneration, and affecting the type of reactions catalyzed by sulfite oxidase family enzymes. PMID:19860477

  12. Shipbuilding and Conversion, Navy, (SCN) Funds Flow for Major Shipbuilding Programs

    DTIC Science & Technology

    1975-05-01

    Idenlty by bloc,. number) SEE ATTACHED SHEET D IAM 1473 EDITION OF I NOV 65 I OBSOLETE SECURITY CLASSIFICATI(Y’ OF THIS PAGE (Whaen Data Lnter..d...A C CEPTRJCE gTA; see foe*s aisa odstiens oe r usifeetey ,..d ~.ect"lJJ I AC -TitU OfIC11 (roe mov ox tite) . fIiNATUMI 40 ~I- MILITARY

  13. Alternative Fuels Data Center: Kentucky Charges Forward with All-Electric

    Science.gov Websites

    Partnership. Download QuickTime Video QuickTime (.mov) Download Windows Media Video Windows Media (.wmv) Video Fuel Cell Vehicles in California Nov. 18, 2017 Photo of a car Smart Car Shopping Nov. 4, 2017 Image of Photo of a truck Natural Gas Fuels School Buses and Refuse Trucks in Tulsa, Oklahoma Feb. 18, 2017 Photo

  14. Knowledge, attitudes, and practices of private sector immunization service providers in Gujarat, India.

    PubMed

    Hagan, José E; Gaonkar, Narayan; Doshi, Vikas; Patni, Anas; Vyas, Shailee; Mazumdar, Vihang; Kosambiya, J K; Gupta, Satish; Watkins, Margaret

    2018-01-02

    India is responsible for 30% of the annual global cohort of unvaccinated children worldwide. Private practitioners provide an estimated 21% of vaccinations in urban centers of India, and are important partners in achieving high vaccination coverage. We used an in-person questionnaire and on-site observation to assess knowledge, attitudes, and practices of private immunization service providers regarding delivery of immunization services in the urban settings of Surat and Baroda, in Gujarat, India. We constructed a comprehensive sampling frame of all private physician providers of immunization services in Surat and Baroda cities, by consulting vaccine distributors, local branches of physician associations, and published lists of private medical practitioners. All providers were contacted and asked to participate in the study if they provided immunization services. Data were collected using an in-person structured questionnaire and directly observing practices; one provider in each practice setting was interviewed. The response rate was 82% (121/147) in Surat, and 91% (137/151) in Baroda. Of 258 participants 195 (76%) were pediatricians, and 63 (24%) were general practitioners. Practices that were potential missed opportunities for vaccination (MOV) included not strictly following vaccination schedules if there were concerns about ability to pay (45% of practitioners), and not administering more than two injections in the same visit (60%). Only 22% of respondents used a vaccination register to record vaccine doses, and 31% reported vaccine doses administered to the government. Of 237 randomly selected vaccine vials, 18% had expired vaccine vial monitors. Quality of immunization services in Gujarat can be strengthened by providing training and support to private immunization service providers to reduce MOVs and improve quality and safety; other more context specific strategies that should be evaluated may involve giving feedback to providers on quality of services delivered and working through professional societies to adopt standards of practice. Published by Elsevier Ltd.

  15. Corrosion of Steel in a Black Mangrove Environment

    DTIC Science & Technology

    1982-10-01

    neceaaary and Identify by block number) Black Mangrove Environment Chloride Salts Corrosion Iron- Tannin Complex Steel Tannic Acid Tropic Test Center...identified to be as follows: rain water falling through the mangrove canopy picks up salts and tannins from the black mangroves. The salts...attack steel, forming water-soluble ferric ions. The tannins react DD , JAN 73 •*/J EDITION OF » MOV 65 IS OBSOLETE UNCLASSIFIED SECURITY

  16. Robotic Prostate Biopsy in Closed MRI Scanner

    DTIC Science & Technology

    2009-02-01

    radioactive seeds or diagnosis by harvesting tissue samples inside the mag- net bore, under remote control of the physician without mov- ing the patient out...and allows fast removal for reloading brachytherapy needles or col- lecting harvested biopsy tissue. The primary actuated motions of the robot...include two prismatic motions and two rotational motions for aligning the needle axis. In addition to these base motions, application-specific motions are

  17. Visualization Development of the Ballistic Threat Geospatial Optimization

    DTIC Science & Technology

    2015-07-01

    topographic globes, Keyhole Markup Language (KML), and Collada files. World Wind gives the user the ability to import 3-D models and navigate...present. After the first person view window is closed , the images stored in memory are then converted to a QuickTime movie (.MOV). The video will be...processing unit HPC high-performance computing JOGL Java implementation of OpenGL KML Keyhole Markup Language NASA National Aeronautics and Space

  18. Morphology and Performance of 5Cr5MoV Casting Die Steel in the Process of Surfacing

    NASA Astrophysics Data System (ADS)

    Song, Yulai; Kong, Xiangrui; Yang, Pengcong; Fu, Hongde; Wang, Xuezhu

    2017-12-01

    To investigate the microstructures and mechanical properties of the deposited metal on surface of die steel, two layer of weld-seam were prepared on the surface of 5Cr5MoV die steel by arc surfacing. The surface microstructures and microhardness were characterized by scanning electron microscopy, energy dispersive spectrometer and Vickers microhardness tester, respectively. The effect of load on the abrasion resistance and wear mechanism of the base metal and surfacing metal was studied by pin-on-disk tribometer. The results showed that martensite and retained austenite exist in weld-seam, both of them grow up in the form of dendrites and equiaxed grains and microhardness reach 774.2HV. The microstructures of the quenching zone mainly consist of martensite and retained austenite, while tempered martensite is the dominant phase in partial quenching zone. The abrasion resistance of the surfacing metal is superior to the base metal based on the results of wear test. The wear rates of surfacing metal and base metal raise with the increase of load. The wear rates of base metal raise extremely when the load reach 210N. Both of two kinds of materials have the similar wear mechanism, namely, abrasive wear at low load, oxidative wear and adhesive wear at high load.

  19. Redox chemistry of molybdenum in natural waters and its involvement in biological evolution

    PubMed Central

    Wang, Deli

    2012-01-01

    The transition element molybdenum (Mo) possesses diverse valances (+II to +VI), and is involved in forming cofactors in more than 60 enzymes in biology. Redox switching of the element in these enzymes catalyzes a series of metabolic reactions in both prokaryotes and eukaryotes, and the element therefore plays a fundamental role in the global carbon, nitrogen, and sulfur cycling. In the present oxygenated waters, oxidized Mo(VI) predominates thermodynamically, whilst reduced Mo species are mainly confined within specific niches including cytoplasm. Only recently has the reduced Mo(V) been separated from Mo(VI) in sulfidic mats and even in some reducing waters. Given the presence of reduced Mo(V) in contemporary anaerobic habitats, it seems that reduced Mo species were present in the ancient reducing ocean (probably under both ferruginous and sulfidic conditions), prompting the involvement of Mo in enzymes including nitrogenase and nitrate reductase. During the global transition to oxic conditions, reduced Mo species were constrained to specific anaerobic habitats, and efficient uptake systems of oxidized Mo(VI) became a selective advantage for current prokaryotic and eukaryotic cells. Some prokaryotes are still able to directly utilize reduced Mo if any exists in ambient environments. In total, this mini-review describes the redox chemistry and biogeochemistry of Mo over the Earth’s history. PMID:23267355

  20. 2006 NRL Review

    DTIC Science & Technology

    2006-01-01

    cool , the ink is solid and does not flow. When the cantilever is heated , the ink melts and flows from the tip onto the surface. Mov­ ing the tip...IBM for use in the “Millipede” memory storage system. Thermal cantilevers may be designed to give rapid heating (1 to 20 µs) and cooling (1 to 50 µs...ability of combin- ing reconfigurable hardware devices with optimization software capable of executing real-time autonomous reconfiguration opens up a

  1. Exercise Desert Rock VII. Operation Order Number 1. Army, Camp Desert Rock, Nevada

    DTIC Science & Technology

    1957-05-11

    te locetod at the rear of the serial. Vehic ’es * td ii break down durirG the mov ant to Uhe observer area will be pushed to the side of the road ni...26th TC Bn,Hq & IHq co 2d TC Truck Co (Peo) 38th TC Co (Hv) 351st TC Co (Red) TC Provisional Aircraft Uaint Det DESE,t- ROCK PROJECTS Project 50.3

  2. Factors affecting the inter-annual to centennial timescale variability of Indian summer monsoon rainfall

    NASA Astrophysics Data System (ADS)

    Malik, Abdul; Brönnimann, Stefan

    2017-09-01

    The Modes of Ocean Variability (MOV) namely Atlantic Multidecadal Oscillation (AMO), Pacific Decadal Oscillation (PDO), and El Niño Southern Oscillation (ENSO) can have significant impacts on Indian Summer Monsoon Rainfall (ISMR) on different timescales. The timescales at which these MOV interacts with ISMR and the factors which may perturb their relationship with ISMR need to be investigated. We employ De-trended Cross-Correlation Analysis (DCCA), and De-trended Partial-Cross-Correlation Analysis (DPCCA) to study the timescales of interaction of ISMR with AMO, PDO, and ENSO using observational dataset (AD 1854-1999), and atmosphere-ocean-chemistry climate model simulations with SOCOL-MPIOM (AD 1600-1999). Further, this study uses De-trended Semi-Partial Cross-Correlation Analysis (DSPCCA) to address the relation between solar variability and the ISMR. We find statistically significant evidence of intrinsic correlations of ISMR with AMO, PDO, and ENSO on different timescales, consistent between model simulations and observations. However, the model fails to capture modulation in intrinsic relationship between ISRM and MOV due to external signals. Our analysis indicates that AMO is a potential source of non-stationary relationship between ISMR and ENSO. Furthermore, the pattern of correlation between ISMR and Total Solar Irradiance (TSI) is inconsistent between observations and model simulations. The observational dataset indicates statistically insignificant negative intrinsic correlation between ISMR and TSI on decadal-to-centennial timescales. This statistically insignificant negative intrinsic correlation is transformed to statistically significant positive extrinsic by AMO on 61-86-year timescale. We propose a new mechanism for Sun-monsoon connection which operates through AMO by changes in summer (June-September; JJAS) meridional gradient of tropospheric temperatures (ΔTTJJAS). There is a negative (positive) intrinsic correlation between ΔTTJJAS (AMO) and TSI. The negative intrinsic correlation between ΔTTJJAS and TSI indicates that high (low) solar activity weakens (strengthens) the meridional gradient of tropospheric temperature during the summer monsoon season and subsequently the weak (strong) ΔTTJJAS decreases (increases) the ISMR. However, the presence of AMO transforms the negative intrinsic relation between ΔTTJJAS and TSI into positive extrinsic and strengthens the ISMR. We conclude that the positive relation between ISMR and solar activity, as found by other authors, is mainly due to the effect of AMO on ISMR.

  3. {Mo96La8} eggshell ring and self-assembly to {Mo132} Keplerate through Mo-blue intermediate, involved in UV-photolysis of [Mo7O24](6-)/carboxylic acid system at pH 4.

    PubMed

    Yamase, Toshihiro; Kumagai, Shun; Prokop, Petra V; Ishikawa, Eri; Tomsa, Adrian-Raul

    2010-10-18

    The prolonged UV-photolysis of aqueous solutions containing [Mo(7)O(24)](6-) and C(2)H(5)CO(2)H (as electron donor) at pH 3.9-4.1 generates the carboxylate-coordinated {Mo(132)} Keplerate (1a) isolated as a formamidinium/ammonium-mixed salt, [HC(NH(2))(2)](26)(NH(4))(28)[Mo(V)(60)Mo(VI)(72)O(372)(H(2)O)(48)(C(2)H(5)CO(2))(36)((i)C(3)H(7)CO(2))(6)]·16H(2)O (1), through the Mo-blue intermediate (2). The coordination of 2 to La(3+) gives rise to the formation of the chain structure of the C(2)-symmetric {Mo(96)La(8)} eggshell rings, formulated by H(22)[Mo(V)(20)Mo(VI)(76)O(301)(H(2)O)(29){La(H(2)O)(6)}(2)]{La(H(2)O)(5)}(6)]·54.5H(2)O (3). The eggshell-ring geometry results from the insertion of [Mo(VI)(2)O(7)(H(2)O)](2-) (spacer) into the equator outer ring of the wheel-shaped Mo-blue, and 10 {(Mo(VI))(Mo(VI)(5))} pentagonal subunits alternately above and below the equator outer ring are connected by eight La(3+) and two {Mo(VI)(2)} linkers within two inner rings. The neighboring eggshell rings are linked through two Mo-O-Mo bonds formed by dehydrative condensation between the {Mo(VI)(2)} linkers to result in the chain structure. Together with the results of the elemental analysis and IR, electronic absorption, (13)C NMR, and ESI-MS spectra for 2, the ring profile analysis of 3 let us identify 2 with a carbolylate-coordinated Mo-blue ring of high nuclearity. The Mo(VI)→Mo(V) photoreductive change of 2 to the 60-electron reduced Keplerate in the presence of C(2)H(5)CO(2)H involves both degradation of the outer ring and splitting of the binuclear linkers, which leads to the formation of [(Mo(VI))Mo(VI)(5)O(21)(H(2)O)(4)(carboxylate)](7-) pentagonal subunits and [Mo(V)(2)O(4)(carboxylate)](+)/[Mo(V)O(2)(carboxylate)(1/2)](0.5+)-mixed linkers for 1.

  4. Factors affecting the inter-annual to centennial timescale variability of Indian summer monsoon rainfall

    NASA Astrophysics Data System (ADS)

    Malik, Abdul; Brönnimann, Stefan

    2018-06-01

    The Modes of Ocean Variability (MOV) namely Atlantic Multidecadal Oscillation (AMO), Pacific Decadal Oscillation (PDO), and El Niño Southern Oscillation (ENSO) can have significant impacts on Indian Summer Monsoon Rainfall (ISMR) on different timescales. The timescales at which these MOV interacts with ISMR and the factors which may perturb their relationship with ISMR need to be investigated. We employ De-trended Cross-Correlation Analysis (DCCA), and De-trended Partial-Cross-Correlation Analysis (DPCCA) to study the timescales of interaction of ISMR with AMO, PDO, and ENSO using observational dataset (AD 1854-1999), and atmosphere-ocean-chemistry climate model simulations with SOCOL-MPIOM (AD 1600-1999). Further, this study uses De-trended Semi-Partial Cross-Correlation Analysis (DSPCCA) to address the relation between solar variability and the ISMR. We find statistically significant evidence of intrinsic correlations of ISMR with AMO, PDO, and ENSO on different timescales, consistent between model simulations and observations. However, the model fails to capture modulation in intrinsic relationship between ISRM and MOV due to external signals. Our analysis indicates that AMO is a potential source of non-stationary relationship between ISMR and ENSO. Furthermore, the pattern of correlation between ISMR and Total Solar Irradiance (TSI) is inconsistent between observations and model simulations. The observational dataset indicates statistically insignificant negative intrinsic correlation between ISMR and TSI on decadal-to-centennial timescales. This statistically insignificant negative intrinsic correlation is transformed to statistically significant positive extrinsic by AMO on 61-86-year timescale. We propose a new mechanism for Sun-monsoon connection which operates through AMO by changes in summer (June-September; JJAS) meridional gradient of tropospheric temperatures (ΔTTJJAS). There is a negative (positive) intrinsic correlation between ΔTTJJAS (AMO) and TSI. The negative intrinsic correlation between ΔTTJJAS and TSI indicates that high (low) solar activity weakens (strengthens) the meridional gradient of tropospheric temperature during the summer monsoon season and subsequently the weak (strong) ΔTTJJAS decreases (increases) the ISMR. However, the presence of AMO transforms the negative intrinsic relation between ΔTTJJAS and TSI into positive extrinsic and strengthens the ISMR. We conclude that the positive relation between ISMR and solar activity, as found by other authors, is mainly due to the effect of AMO on ISMR.

  5. Properties of synaptic transmission from the reticular formation dorsal to the facial nucleus to trigeminal motoneurons during early postnatal development in rats.

    PubMed

    Gemba-Nishimura, A; Inoue, T; Nakamura, S; Nakayama, K; Mochizuki, A; Shintani, S; Yoshimura, S

    2010-03-31

    We previously reported that electrical stimulation of the reticular formation dorsal to the facial nucleus (RdVII) elicited excitatory masseter responses at short latencies and that RdVII neurons were antidromically activated by stimulation of the trigeminal motor nucleus (MoV), suggesting that excitatory premotor neurons targeting the MoV are likely located in the RdVII. We thus examined the properties of synaptic transmission from the RdVII to jaw-closing and jaw-opening motoneurons in horizontal brainstem preparations from developing rats using voltage-sensitive dye, patch-clamp recordings and laser photostimulation. Electrical stimulation of the RdVII evoked optical responses in the MoV. Combined bath application of the non-N-methyl-d-aspartate (non-NMDA) receptor antagonist 6-cyano-7-nitroquinoxaline-2,3-dione (CNQX), and the NMDA receptor antagonist DL-2-amino-5-phosphonopentanoic acid (APV) reduced these optical responses, and addition of the glycine receptor antagonist strychnine and the GABA(A) receptor antagonist bicuculline further reduced the remaining responses. Electrical stimulation of the RdVII evoked postsynaptic currents (PSCs) in all 19 masseter motoneurons tested in postnatal day (P)1-4 rats, and application of CNQX and the NMDA receptor antagonist (+/-)-3(2-carboxypiperazin-4-yl)propyl-1-phosphonic acid (CPP) reduced the PSC amplitudes by more than 50%. In the presence of CNQX and CPP, the GABA(A) receptor antagonist SR95531 further reduced PSC amplitude, and addition of strychnine abolished the remaining PSCs. Photostimulation of the RdVII with caged glutamate also evoked PSCs in masseter motoneurons of P3-4 rats. In P8-11 rats, electrical stimulation of the RdVII also evoked PSCs in all 14 masseter motoneurons tested, and the effects of the antagonists on the PSCs were similar to those in P1-4 rats. On the other hand, RdVII stimulation evoked PSCs in only three of 16 digastric motoneurons tested. These results suggest that both neonatal and juvenile jaw-closing motoneurons receive strong synaptic inputs from the RdVII through activation of glutamate, glycine and GABA(A) receptors, whereas inputs from the RdVII to jaw-opening motoneurons seem to be weak. Copyright 2010 IBRO. Published by Elsevier Ltd. All rights reserved.

  6. Serious Gaming Technologies Support Human Factors Investigations of Advanced Interfaces for Semi-Autonomous Vehicles

    DTIC Science & Technology

    2006-06-01

    conventional camera vs. thermal imager vs. night vision; camera field of view (narrow, wide, panoramic); keyboard + mouse vs. joystick control vs...motorised platform which could scan the immediate area, producing a 360o panorama of “stitched-together” digital pictures. The picture file, together with...VBS was used to automate the process of creating a QuickTime panorama (.mov or .qt), which includes the initial retrieval of the images, the

  7. Platinum Group Coatings for Refractory Metals

    DTIC Science & Technology

    1984-06-01

    temperatures and deposition was very slow. We decided to try iridium hexaflouride, Siridium trichloride hydrate, iridiuw carbonyl and tris-acetyl acetonato...T:*ouu sue. CO. Rhenium Refractory Metals 03 1 d.pRsiý C rg Iridium Coatings 2i 8 bapo i 10. ASSTRACT Won#~.. on mov ofot~sfte.. iad k.dhItfV by b...b q Oxidation resistant coatings of iridium on rhenium substrates have been produced by chemical vapor deposition from an iridium acetyl acetonate

  8. The Perception of the Higher Derivatives of Visual Motion.

    DTIC Science & Technology

    1986-06-24

    uniform velocity in one run with a target mov- ing with either an accelerating or decelerating motion on another run , and had to decide on which of...the two runs the motion was uniform. It was found that sensitivity to acceleration (as indicated by proportion of correct dis- criminations) decreased...20 subjects had 8 In an experiment by Runeson (1975), one target (the stan- tracking runs with each of the three tvpes of moving target. The third

  9. Crystallization of a Keplerate-type polyoxometalate into a superposed kagome-lattice with huge channels.

    PubMed

    Saito, Masaki; Ozeki, Tomoji

    2012-09-07

    Crystal structures of two Sr(2+) salts of the Keplerate-type polyoxometalate, [Mo(VI)(72)Mo(V)(60)O(372)(CH(3)COO)(30)(H(2)O)(72)](42-), have been determined by single crystal X-ray diffraction. One compound exhibits a superposed kagome-lattice with huge channels whose diameters measure approximately 3.0 nm, while the arrangement of the Keplerate anions in the other compound approximates to a distorted cubic close packing.

  10. Strengthening Sustainability and Resiliency of a Future Force, Phase 1. FY2010-2011 Summer Study

    DTIC Science & Technology

    2011-03-01

    Resiliency of a Future Force: Phase I Interim Report - 48 Please Enter Custom Water factor adjustments below: m Unit Level* (Gat/Ptisan/ Dti ...cost of mov- ing the consumables in terms of the assets required to move the commodity and the security Intra Theater Resupply: 4 Legs Army...Expeditionary Force-Logistics ResupplyDetails Legl Leg 2 Leg 3 Leg 4 Resupply Trip Legs Super FOB (Div)to Base Camp (bde) Base Camp (Bde) to FOB (Bn

  11. Digital Control System for An On-Borad Oxygen Generator

    DTIC Science & Technology

    1980-12-01

    pecple who contributed to the success of this thesis. They include the following: Major Borky, my thesis advisor; the entire staff of the Electrical ...to required concentration. OE4 23 MOV A, # Combine rotation direction OE5 OD 0000/1101 with LEC control and016 4Q ORL A, R3 output resulItsOE7 AB MDV ...then attended the University of Texas at Austin and graduated with a Bachelor of Science degree in Electrical Engineering in 1971. After graduation, he

  12. Trapping {BW12}2 tungstoborate: synthesis and crystal structure of hybrid [{(H2BW12O42)2O}{Mo6O6S6(OH)4(H2O)2}]14- anion.

    PubMed

    Korenev, V S; Abramov, P A; Vicent, C; Mainichev, D A; Floquet, S; Cadot, E; Sokolov, M N; Fedin, V P

    2012-12-28

    Reaction between monolacunary {BW(11)} tungstoborate and oxothiocationic building block, {Mo(2)O(2)S(2)}, results in the formation of a new polyoxothiometalate with a unique architecture in which two [H(2)BW(12)O(43)](9-) tungstoborate subunits are linked together with a hexamolybdate [Mo(V)(6)O(6)S(6)(OH)(4)(H(2)O)(2)](2+) bridge.

  13. A new oxomolybdate component extracted from the "virtual dynamic library" yielding the macrocyclic anion [(Mo(VI)(8)O(28))(4)(Mo(V)(2)O(2)S(2))(4)](24-).

    PubMed

    Korenev, Vladimir S; Boulay, Antoine G; Dolbecq, Anne; Sokolov, Maxim N; Hijazi, Akram; Floquet, Sébastien; Fedin, Vladimir P; Cadot, Emmanuel

    2010-11-01

    A rare isomer of the {Mo(8)O(28)}(8-) anion has been trapped from an acidified aqueous solution of molybdate by using the {Mo(2)O(2)S(2)}(2+) oxothio cation as the linker and isolated as a part of a unique macrocyclic anion, which consists of four isopolyoxomolybdate fragments {Mo(8)O(28)} bridged by four {Mo(2)O(2)S(2)} units.

  14. Infrared Heat Lamps used in Drying Chemical Samples, September-October 1974

    DTIC Science & Technology

    1974-10-01

    reflected from the planchette exceeds current recommended limits. DD F2MM73 1473 ED’Tt0" OF ’MOV •*IS o"SOLETE UNCLASSIFIED SECÜmTY CLASSIFICATION OF... planchette exceeds current recommended limits. Recommendations include reducing reflected luminance from the sample planchette and placing a warning...Samples, Sep-Oct 74 Figure 1. Nuclear Associates Sample Dryer Showing Metal Planchettes and Heat Lamp at Top of Page •■;’^’""- ■■ ■ ■ *wmzm

  15. Toxicity of TNT Wastewaters to Aquatic Organisms. Volume 1. Acute Toxicity of LAP Wastewater and 2,4,6-Trinitrotoluene

    DTIC Science & Technology

    1983-03-01

    trinitrobenzonitrile, 1, 3,5-trinitrobenzene, and 4,6-dinitroanthranil, which are phototransformation products of TNT and RDX. D D tA 1473 mSTIo ar I mov Is is...toxicity of these materials decreased as the photolytic degradation of TNT in- creased. The phototransformaticn products of TNT were generally mcre...Department of the Army endorsement or approval of the products or services of these organizations. Acco:sion For NTIS CG’iA&I DTIC TAB Unnnnoilinced

  16. SFD-261 Crossed-Field Amplifier Manufacturing Technology Program.

    DTIC Science & Technology

    1979-09-28

    microwave amplifier used to increase tet pow--rlel of pulses of energy by a factor of 20. It is used in the Aegis A4/SPY1V DD 1473 ECIIOwOF I MOV 65...transmitter. A single ship.,; complement without spares is seventy-six. Its internal parts are made from high purity copper and many are complex and...23 Cathode Support 39 24 Mounting Plate ’i 25 Support Plate 42 26 Tubing Support 43 27 SFD-261 High Voltage Can End 45 b 28 Comparison of MT Tube

  17. The research of axial corrosion fatigue on 10Ni3CrMoV steel

    NASA Astrophysics Data System (ADS)

    Xie, Xing; Yi, Hong; Xu, Jian; Xie, Kun

    2017-09-01

    Fatigue life had been studied with 10CrNi3MoV steel at different load ratios and in different environmental medias. The microstructure and micro-topography had been observed and analyzed by means of SEM, EDS and TEM. Our findings indicated that, the fatigue life of 10Ni3CrMoV steel in seawater was shorter than in air, the difference in longevity was larger with the decreasing of axis stress. Corrosion pits had a great influence on corrosion fatigue life.

  18. Effect of T-2 Toxin, Fasting, and 2-Methyl-thiazolidine-4-carboxylate, a Glutathione Prodrug, on Hepatic Glutathione Levels1,2

    DTIC Science & Technology

    1986-11-14

    Iftnvi fnr fard mirn: O Fo, M73 3 r0tiON OF I MOV 6s IS OBSOLETE SECURITY CLASSIFICATION OF THIS PACE (When Does Entoeed) , I I I I I 4.5± 0.39...Glende, 1973). An important cellular defense against peroxida- tive damage is the presence of glutathione and its use as an enzyme substrate or...cofactor. Even though intracellular glutathione concentration is in the millimolar range (Kosower and Kosower, 1978), there are conditions which lead to

  19. Control Electronics for Air-Borne Quadrupole Ion Mass Spectrometer.

    DTIC Science & Technology

    1981-10-01

    If .1J ACN1 A 7 SIA A,) ADI ;’C NI’~ ’IA N, 41t ; :)’’’ DATA ICJ M TOS F1 95 .SVf 9,O~ 1iIC CCHF03)~2 C if 1:-TR 1YU .1 1.1 Ui; C .. XkA A OUT "A4...OUT 0FBH ;OUTrPUT TO ANY G71 LXI H, 1962H ;LOAD -HL- WITH ANALOG 5 POINTER SCALL ALLDEF JC G48 ;JUMP IF BYPASSED MOV A, L i - 289- OUT OF9H ;OUTPUT TO

  20. Development of a potentiometric EDTA method for determination of molybdenum. Use of the analysis for molybdenite concentrates

    NASA Technical Reports Server (NTRS)

    Khristova, R.; Vanmen, M.

    1986-01-01

    Based on considerations of principles and experimental data, the interference of sulfate ions in poteniometric titration of EDTA with FeCl3 was confirmed. The method of back complexometric titration of molybdenum of Nonova and Gasheva was improved by replacing hydrazine sulfate with hydrazine hydrochloride for reduction of Mo(VI) to Mo(V). The method can be used for one to tenths of mg of molybdenum with 0.04 mg standard deviation. The specific method of determination of molybdenum in molybdenite concentrates is presented.

  1. Plant maintenance and advanced reactors issue, 2004

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agnihotri, Newal

    2004-09-15

    The focus of the September-October issue is on plant maintenance and advanced reactors. Major articles/reports in this issue include: Optimism about the future of nuclear power, by Ruth G. Shaw, Duke Power Company; Licensed in three countries, by GE Energy; Enhancing public acceptance, by Westinghouse Electric Company; Standardized MOV program, by Ted Neckowicz, Exelon; Inservice testing, by Steven Unikewicz, U.S. Nuclear Regulatory Commission; Asian network for education, Fatimah Mohd Amin, Malaysian Institute for Nuclear Technology Research; and, Cooling water intake optimization, by Jeffrey M. Jones and Bert Mayer, P.E., Framatome ANP.

  2. A further step towards tuning the properties of metal-chalcogenide nanocapsules by replacing skeletal oxide by sulphide ligands.

    PubMed

    Schäffer, Christian; Todea, Ana Maria; Bögge, Hartmut; Floquet, Sébastien; Cadot, Emmanuel; Korenev, Vladimir S; Fedin, Vladimir P; Gouzerh, Pierre; Müller, Achim

    2013-01-14

    Addition of [Mo(2)(V)O(2)(μ-O)(μ-S)(aq)](2+) linker-type units to a solution/dynamic library containing tungstates results via the formation of the complementary pentagonal {(W)W(5)} units logically in the self-assembly of a mixed oxide/sulphide {W(VI)(72)Mo(V)(60)}-type Keplerate, thereby demonstrating the ability to tune the capsule's skeletal softness (the (μ-O)(2) and (μ-S)(2) scenarios are known) and providing options to influence differently important capsule-substrate interactions.

  3. Demand Controlled Economizer Cycles: A Direct Digital Control Scheme for Heating, Ventilating, and Air Conditioning Systems,

    DTIC Science & Technology

    1984-05-01

    Control Ignored any error of 1/10th degree or less. This was done by setting the error term E and the integral sum PREINT to zero If then absolute value of...signs of two errors jeq tdiff if equal, jump clr @preint else zero integal sum tdiff mov @diff,rl fetch absolute value of OAT-RAT ci rl,25 is...includes a heating coil and thermostatic control to maintain the air in this path at an elevated temperature, typically around 80 degrees Farenheit (80 F

  4. Enhanced Wnt signaling improves bone mass and strength, but not brittleness, in the Col1a1(+/mov13) mouse model of type I Osteogenesis Imperfecta.

    PubMed

    Jacobsen, Christina M; Schwartz, Marissa A; Roberts, Heather J; Lim, Kyung-Eun; Spevak, Lyudmila; Boskey, Adele L; Zurakowski, David; Robling, Alexander G; Warman, Matthew L

    2016-09-01

    Osteogenesis Imperfecta (OI) comprises a group of genetic skeletal fragility disorders. The mildest form of OI, Osteogenesis Imperfecta type I, is frequently caused by haploinsufficiency mutations in COL1A1, the gene encoding the α1(I) chain of type 1 collagen. Children with OI type I have a 95-fold higher fracture rate compared to unaffected children. Therapies for OI type I in the pediatric population are limited to anti-catabolic agents. In adults with osteoporosis, anabolic therapies that enhance Wnt signaling in bone improve bone mass, and ongoing clinical trials are determining if these therapies also reduce fracture risk. We performed a proof-of-principle experiment in mice to determine whether enhancing Wnt signaling in bone could benefit children with OI type I. We crossed a mouse model of OI type I (Col1a1(+/Mov13)) with a high bone mass (HBM) mouse (Lrp5(+/p.A214V)) that has increased bone strength from enhanced Wnt signaling. Offspring that inherited the OI and HBM alleles had higher bone mass and strength than mice that inherited the OI allele alone. However, OI+HBM and OI mice still had bones with lower ductility compared to wild-type mice. We conclude that enhancing Wnt signaling does not make OI bone normal, but does improve bone properties that could reduce fracture risk. Therefore, agents that enhance Wnt signaling are likely to benefit children and adults with OI type 1. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. The H-bond network surrounding the pyranopterins modulates redox cooperativity in the molybdenum-bisPGD cofactor in arsenite oxidase.

    PubMed

    Duval, Simon; Santini, Joanne M; Lemaire, David; Chaspoul, Florence; Russell, Michael J; Grimaldi, Stephane; Nitschke, Wolfgang; Schoepp-Cothenet, Barbara

    2016-09-01

    While the molybdenum cofactor in the majority of bisPGD enzymes goes through two consecutive 1-electron redox transitions, previous protein-film voltammetric results indicated the possibility of cooperative (n=2) redox behavior in the bioenergetic enzyme arsenite oxidase (Aio). Combining equilibrium redox titrations, optical and EPR spectroscopies on concentrated samples obtained via heterologous expression, we unambiguously confirm this claim and quantify Aio's redox cooperativity. The stability constant, Ks, of the Mo(V) semi-reduced intermediate is found to be lower than 10(-3). Site-directed mutagenesis of residues in the vicinity of the Mo-cofactor demonstrates that the degree of redox cooperativity is sensitive to H-bonding interactions between the pyranopterin moieties and amino acid residues. Remarkably, in particular replacing the Gln-726 residue by Gly results in stabilization of (low-temperature) EPR-observable Mo(V) with KS=4. As evidenced by comparison of room temperature optical and low temperature EPR titrations, the degree of stabilization is temperature-dependent. This highlights the importance of room-temperature redox characterizations for correctly interpreting catalytic properties in this group of enzymes. Geochemical and phylogenetic data strongly indicate that molybdenum played an essential biocatalytic roles in early life. Molybdenum's redox versatility and in particular the ability to show cooperative (n=2) redox behavior provide a rationale for its paramount catalytic importance throughout the evolutionary history of life. Implications of the H-bonding network modulating Molybdenum's redox properties on details of a putative inorganic metabolism at life's origin are discussed. Copyright © 2016. Published by Elsevier B.V.

  6. Oxidation-reduction potentials of molybdenum, flavin and iron-sulphur centres in milk xanthine oxidase.

    PubMed Central

    Cammack, R; Barber, M J; Bray, R C

    1976-01-01

    1. The mid-point reduction potentials of the various groups in xanthine oxidase from bovine milk were determined by potentiometric titration with dithionite in the presence of dye mediators, removing samples for quantification of the reduced species by e.p.r. (electron-paramagnetic-resonance) spectroscopy. The values obtained for the functional enzyme in pyrophosphate buffer, pH8.2, are: Fe/S centre I, -343 +/- 15mV; Fe/S II, -303 +/- 15mV; FAD/FADH-; -351 +/- 20mV; FADH/FADH2, -236 +/-mV; Mo(VI)/Mo(V) (Rapid), -355 +/- 20mV; Mo(V) (Rapid)/Mo(IV), -355 +/- 20mV. 2. Behaviour of the functional enzyme is essentially ideal in Tris but less so in pyrophosphate. In Tris, the potential for Mo(VI)/Mo(V) (Rapid) is lowered relative to that in pyrophosphate, but the potential for Fe/S II is raised. The influence of buffer on the potentials was investigated by partial-reduction experiments with six other buffers. 3. Conversion of the enzyme with cyanide into the non-functional form, which gives the Slow molybdenum signal, or alkylation of FAD, has little effect on the mid-point potentials of the other centres. The potentials associated with the Slow signal are: Mo(VI)/Mo(V) (Slow), -440 +/- 25mV; Mo(V) (Slow)/Mo(IV), -480 +/- 25 mV. This signal exhibits very sluggish equilibration with the mediator system. 4. The deviations from ideal behaviour are discussed in terms of possible binding of buffer ions or anti-co-operative interactions amongst the redox centres. PMID:183752

  7. An Investigation of the Mold-Flux Performance for the Casting of Cr12MoV Steel Using a Mold Simulator Technique

    NASA Astrophysics Data System (ADS)

    Zhou, Lejun; Wang, Wanlin; Xu, Chao; Zhang, Chen

    2017-08-01

    Mold flux plays important roles in the process of continuous casting. In this article, the performance of mold flux for the casting of Cr12MoV steel was investigated by using a mold simulator. The results showed that the slag film formed in the gap between the initial shell and mold hot surface is thin and discontinuous during the casting process with the Flux BM, due to the absorption of chromic oxide inclusions into the liquid slag, while the slag film formed in the case of the optimized Flux NEW casting process is uniform. The main precipitated crystals in Flux BM slag film are cuspidine (Ca4Si2O7F2) and Cr3O4, but only Ca4Si2O7F2 precipitated in the Flux NEW case. Besides, both the responding temperature and heat flux in the case of Flux BM are relatively higher and fluctuate in a larger amplitude. The surface of the shell obtained in the case of the Flux BM experiment is quite uneven, and many severe depressions, cracks, and entrapped slags are observed in the surface due to the lack of lubrication. However, the obtained shell surface in the case of the Flux NEW shows good surface quality due to the addition of B2O3 and the adjustment of basicity, which can compensate for the negative effects of the mold-flux properties caused by the absorption of chromic oxide during the casting process.

  8. Effect of Spheroidizing Annealing on Microstructure and Mechanical Properties of High-Carbon Martensitic Stainless Steel 8Cr13MoV

    NASA Astrophysics Data System (ADS)

    Yu, Wen-Tao; Li, Jing; Shi, Cheng-Bin; Zhu, Qin-Tian

    2017-02-01

    The effects of holding time during both austenitizing and spheroidizing on microstructure and mechanical properties of high-carbon martensitic stainless steel 8Cr13MoV were experimentally studied. The results showed that the amount of carbides and the proportion of fine carbides decrease first and then increase with the increase in austenitizing time ( t 1) in the case of short spheroidizing time ( t 2), whereas the amount of the lamellar carbides increases. In the case of long t 2, both the amount of carbides and the proportion of fine carbides decrease, and the amount of the lamellar carbides did not increase. The hardness of the steel decreases first and then increases with the increase of t 1. Under the conditions of different t 1, the change in the size of carbides and hardness of the steel show a same trend with the variation of t 2. The size of spheroidized carbides increases, whereas the hardness of the steel decreases with increasing t 2. The longer the holding time of austenitizing, the higher is the spheroidizing rate at the earlier stage. However, the spheroidizing rate shows an opposite trend with t 1 at the later stage of spheroidizing. The effect of cooling rate on microstructure is similar with t 2. With increasing cooling rate, the dimension of carbides became smaller, and the amount of lamellar carbides increased. The elongation of the sample fracture exhibits no corresponding relationship with holding time, whereas it is closely related to the precipitation of secondary carbides caused by the alloying elements segregation.

  9. Ada Compiler Validation Summary Report: Certificate Number: 900131I1. 10269,Telesoft and MODCOMP, MODCOMP TeleGen2 Ada System, MODCOMP 9730 Host and Target

    DTIC Science & Technology

    1990-01-31

    STrh FILE COPy 0 REPORT DOCUMENTATION PAGE O OW .- Sba,-, S Vm, _.b~ ,, S a. 1__ __ ,,.In ,,IWu O Sim w q viwim. _S . W .-.- smi Won m m,,~Ov -f ym...nd MODCOMP, MODCOMP TeleGen2 Ada System, MODUOMP 9730 (Hostt to arget), 90013111. 10269 CJ S AUHOR( S ) IABG-AVF 101tobrunn, FEDERAL REPUBLIC OF GERMANY...1. ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ a AGENCYG US NY(M W)LAP~rDT ~ ~ TTp N AE ORDIATO . PFIUNDI OGGNITION NAE( S ) ADO OOESS(ES) NUBER S IABG-AVF, Industr

  10. Endogenous proteolytic cleavage of disease-associated prion protein to produce C2 fragments is strongly cell- and tissue-dependent.

    PubMed

    Dron, Michel; Moudjou, Mohammed; Chapuis, Jérôme; Salamat, Muhammad Khalid Farooq; Bernard, Julie; Cronier, Sabrina; Langevin, Christelle; Laude, Hubert

    2010-04-02

    The abnormally folded form of the prion protein (PrP(Sc)) accumulating in nervous and lymphoid tissues of prion-infected individuals can be naturally cleaved to generate a N-terminal-truncated fragment called C2. Information about the identity of the cellular proteases involved in this process and its possible role in prion biology has remained limited and controversial. We investigated PrP(Sc) N-terminal trimming in different cell lines and primary cultured nerve cells, and in the brain and spleen tissue from transgenic mice infected by ovine and mouse prions. We found the following: (i) the full-length to C2 ratio varies considerably depending on the infected cell or tissue. Thus, in primary neurons and brain tissue, PrP(Sc) accumulated predominantly as untrimmed species, whereas efficient trimming occurred in Rov and MovS cells, and in spleen tissue. (ii) Although C2 is generally considered to be the counterpart of the PrP(Sc) proteinase K-resistant core, the N termini of the fragments cleaved in vivo and in vitro can actually differ, as evidenced by a different reactivity toward the Pc248 anti-octarepeat antibody. (iii) In lysosome-impaired cells, the ratio of full-length versus C2 species dramatically increased, yet efficient prion propagation could occur. Moreover, cathepsin but not calpain inhibitors markedly inhibited C2 formation, and in vitro cleavage by cathepsins B and L produced PrP(Sc) fragments lacking the Pc248 epitope, strongly arguing for the primary involvement of acidic hydrolases of the endolysosomal compartment. These findings have implications on the molecular analysis of PrP(Sc) and cell pathogenesis of prion infection.

  11. Endogenous Proteolytic Cleavage of Disease-associated Prion Protein to Produce C2 Fragments Is Strongly Cell- and Tissue-dependent*

    PubMed Central

    Dron, Michel; Moudjou, Mohammed; Chapuis, Jérôme; Salamat, Muhammad Khalid Farooq; Bernard, Julie; Cronier, Sabrina; Langevin, Christelle; Laude, Hubert

    2010-01-01

    The abnormally folded form of the prion protein (PrPSc) accumulating in nervous and lymphoid tissues of prion-infected individuals can be naturally cleaved to generate a N-terminal-truncated fragment called C2. Information about the identity of the cellular proteases involved in this process and its possible role in prion biology has remained limited and controversial. We investigated PrPSc N-terminal trimming in different cell lines and primary cultured nerve cells, and in the brain and spleen tissue from transgenic mice infected by ovine and mouse prions. We found the following: (i) the full-length to C2 ratio varies considerably depending on the infected cell or tissue. Thus, in primary neurons and brain tissue, PrPSc accumulated predominantly as untrimmed species, whereas efficient trimming occurred in Rov and MovS cells, and in spleen tissue. (ii) Although C2 is generally considered to be the counterpart of the PrPSc proteinase K-resistant core, the N termini of the fragments cleaved in vivo and in vitro can actually differ, as evidenced by a different reactivity toward the Pc248 anti-octarepeat antibody. (iii) In lysosome-impaired cells, the ratio of full-length versus C2 species dramatically increased, yet efficient prion propagation could occur. Moreover, cathepsin but not calpain inhibitors markedly inhibited C2 formation, and in vitro cleavage by cathepsins B and L produced PrPSc fragments lacking the Pc248 epitope, strongly arguing for the primary involvement of acidic hydrolases of the endolysosomal compartment. These findings have implications on the molecular analysis of PrPSc and cell pathogenesis of prion infection. PMID:20154089

  12. A Low-Cost, Passive Navigation Training System for Image-Guided Spinal Intervention.

    PubMed

    Lorias-Espinoza, Daniel; Carranza, Vicente González; de León, Fernando Chico-Ponce; Escamirosa, Fernando Pérez; Martinez, Arturo Minor

    2016-11-01

    Navigation technology is used for training in various medical specialties, not least image-guided spinal interventions. Navigation practice is an important educational component that allows residents to understand how surgical instruments interact with complex anatomy and to learn basic surgical skills such as the tridimensional mental interpretation of bidimensional data. Inexpensive surgical simulators for spinal surgery, however, are lacking. We therefore designed a low-cost spinal surgery simulator (Spine MovDigSys 01) to allow 3-dimensional navigation via 2-dimensional images without altering or limiting the surgeon's natural movement. A training system was developed with an anatomical lumbar model and 2 webcams to passively digitize surgical instruments under MATLAB software control. A proof-of-concept recognition task (vertebral body cannulation) and a pilot test of the system with 12 neuro- and orthopedic surgeons were performed to obtain feedback on the system. Position, orientation, and kinematic variables were determined and the lateral, posteroanterior, and anteroposterior views obtained. The system was tested with a proof-of-concept experimental task. Operator metrics including time of execution (t), intracorporeal length (d), insertion angle (α), average speed (v¯), and acceleration (a) were obtained accurately. These metrics were converted into assessment metrics such as smoothness of operation and linearity of insertion. Results from initial testing are shown and the system advantages and disadvantages described. This low-cost spinal surgery training system digitized the position and orientation of the instruments and allowed image-guided navigation, the generation of metrics, and graphic recording of the instrumental route. Spine MovDigSys 01 is useful for development of basic, noninnate skills and allows the novice apprentice to quickly and economically move beyond the basics. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Structural characterization of precious-mean quasiperiodic Mo/V single-crystal superlattices grown by dual-target magnetron sputtering

    NASA Astrophysics Data System (ADS)

    Birch, J.; Severin, M.; Wahlström, U.; Yamamoto, Y.; Radnoczi, G.; Riklund, R.; Sundgren, J.-E.; Wallenberg, L. R.

    1990-05-01

    A class of quasiperiodic superlattice structures, which can be generated by the concurrent inflation rule A-->AmB and B-->A (where m=positive integer), has been studied both theoretically and experimentally. Given that the ratios between the thicknesses of the two superlattice building blocks, A and B, are chosen to be γ(m)=[m+(m2+4)1/2]/2 (known as the ``precious means''), then the x-ray- and electron-diffraction peak positions are analytically found to be located at the wave vectors q=2πΛ-1r[γ(m)]k, where r and k are integers and Λ is an average superlattice wavelength. The analytically obtained results have been compared to experimental results from single-crystalline Mo/V superlattice structures, generated with m=1, 2, and 3. The superlattices were grown by dual-target dc-magnetron sputtering on MgO(001) substrates kept at 700 °C. X-ray diffraction (XRD) and selected-area electron diffraction (SAED) showed that the analytical model mentioned above predicts the peak positions of the experimental XRD and SAED spectra with a very high accuracy. Furthermore, numerical calculations of the diffraction intensities based on a kinematical model of diffraction showed good agreement with the experimental data for all three cases. In addition to a direct verification of the quasiperiodic modulation, both conventional and high-resolution cross-sectional transmission electron microscopy (XTEM) showed that the superlattices are of high crystalline quality with sharp interfaces. Based on lattice resolution images, the width of the interfaces was determined to be less than two (002) lattice-plane spacings (~=0.31 nm).

  14. Discovery and functional characterization of microRNAs and their potential roles for gonadal development in spotted knifejaw, Oplegnathus punctatus.

    PubMed

    Du, Xinxin; Liu, Xiaobing; Zhang, Kai; Liu, Yuxiang; Cheng, Jie; Zhang, Quanqi

    2018-05-16

    The spotted knifejaw (Oplegnathus punctatus) is a newly emerging economical fishery species in China. Studies focused on the regulation of gonadal development and gametogenesis of spotted knifejaw are still insufficient. As a key post-transcriptional regulator, miRNAs have been shown to play important roles in development and reproduction systems. In this study, small RNA deep sequencing in ovary and testis of spotted knifejaw were performed to screen miRNA expression patterns. After sequencing and bioinformatics analysis, a total of 247 conserved known miRNAs and 41 novel miRNAs were identified in spotted knifejaw gonads for the first time. In addition, 36 miRNAs were differentially expressed between testis and ovary. The putative target genes of differentially expressed (DE) miRNAs were significantly enriched in several pathways related to sexual differentiation and gonadal development, such as steroid hormone biosynthesis. Sequencing data was validated through qRT-PCR analysis of selected DE miRNAs. Dual-luciferase reporter analyses of filtered miRNA-target gene pairs confirmed that opu-miR-27b-3p targeted in piwi2 and mov10l1 3' UTRs and down-regulated their expressions in spotted knifejaw. The notion that mov10l1 and piwi2 enhance germ cells proliferation and regulate gonadal development and gametogenesis suggests that opu-miR-27b-3p may attenuated this process in the gonads of spotted knifejaw. These findings provided insights into regulatory roles of gonadal miRNAs and supplied fundamental resources for further studies on miRNA-mediated post-transcriptional regulation in reproductive system of spotted knifejaw. Copyright © 2018. Published by Elsevier Inc.

  15. National Dam Safety Program. J. Bristow Lake Dam (MO 30985), Mississippi - Kaskaskia - St. Louis River Basin, Crawford County, Missouri. Phase I Inspection Report.

    DTIC Science & Technology

    1980-08-01

    8217 m’-* k TOW LAKE DAM -- CRAWFORD COUNTY, MISSOURI * ~MO 30MS PHASE 1 INSPECTION REPORT NATIONAL DAM SAFETY PROGRAM Unkd Ska AnviV €Ow" of Ifntineers I...REPORT NUMBER Crawford County, Missouri 7. AUTHOR() 1 . CONTRACT OR GRANT NUMBER(@) Anderson Engineering, Inc. D6ACW4 3-8j-C-#73 9. PERFORMING ORGANIZATION...oF 1 MOV SS IS O~LET’E 𔄃UNCLASSIFIED SECUFITY CLASSIFICATION OF THIS PAGE (When Dote Entered) SI ’ SECURITY CLASSIFICATION OF THIS PAOR(3SOM DOS a

  16. Effect of load ratio and saltwater corrosive environment on the initiation life of fatigue of 10Ni5CrMoV steel

    NASA Astrophysics Data System (ADS)

    Xie, Xing; Yi, Hong; Xu, Jian; Gen, Liming; Chen, Luyun

    2017-09-01

    Fatigue initiation life has been studied with 10CrNi5MoV steel for use in ocean engineering at different load ratios and in different environmental media. The microstructure and micro-topography have been observed and analyzed by means of SEM, EDS and EBSD. Our findings indicate that, the initiation life of 10Ni5CrMoV steel in seawater is shorter than that in air, and the difference in longevity is larger with the increasing of load ratio. Corrosion pits had a great influence on initial corrosion fatigue life.

  17. Underdrain Systems for Large Structures Placed Below the Groundwater Table.

    DTIC Science & Technology

    1986-08-01

    460 -MODE 177 25. 76.2322 Vs 62.666 -moDE 176 x s 76.6667 Vs a 61.22 DoDE ISO 2. 73.0000 Vs s0.o 0 Done IS& , 62.0000 Vs 0.0000 mov DOSE lE Es 2.0000...426 166 iI 017 166150 161 40 .00006600 .200006400 0. 4 141 ISO 116 166 460 11 143 142 .200006600 .200006600 0. 4 142 III IGO Ii 162 152 145 166...200006*00 .20000600 0. 66 146 152 162 163 166 153 147 165 .00006600 .200006600 0. 46 166 16 171 172 172 1016111 ISO .2000000 .200006600 0. 4• 10 II ?? T

  18. USSR and Eastern Europe Scientific Abstracts Engineering and Equipment No.29

    DTIC Science & Technology

    1977-02-08

    Perlite (12CrlMoV and 12Cr2MoVSib), ferrite - martensite (lCrllW2MoV), and austentite (Crl8Nil2Ti) steels are discussed for use in the heat-transfer...620°C. Other austentite steels have been developed, including EI695R, EP184, EP17, 45Crl0Mnl4Al-2 (which has a 20-40% ferrite phase ), 0Crl3Mnl2Ni2NSi2...middle zone of 10 mm and at the corners -- up to 40 mm. The shell was reinforced with a grid having square meshes of low -carbon steel wire, 1 mm in diam

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dinwiddie, R. B.; Wang, H.; Johnnerfelt, B.

    Zinc Oxide based surge arresters are widely used to safeguard and improve reliability of the electrical power delivering and transmission systems. The primary application of surge arresters is to protect valuable components such as transformers from lightning strikes and switching transients in the transmission lines. Metal-oxide-varistor blocks (MOV, e.g. ZnO) are used in surge arrester assemblies. ORNL has developed an advanced infrared imaging technique to monitor the joule heating during transient heating of small varistors. In a recent short-term R&D effort, researchers from ABB and ORNL have expanded the use of IR imaging to larger station-class arrester blocks. An on-sitemore » visit to the ABB facility demonstrated that the use of IR imaging is not only feasible but also has the potential to improve arrester quality and reliability. The ASEA Brown Bower (ABB) Power and Technology & Development Company located at Greensburg PA having benefited from collaborative R&D cooperation with ORNL. ABB has decided a follow-on CRADA project is very important. While the previous efforts to study surge arresters included broader studies of IR imaging and computer modeling, ABB has recognized the potential of IR imaging, decided to focus on this particular area. ABB plans to use this technique to systematically study the possible defects in the arrester fabrication process. ORNL will improve the real-time monitoring capability and provide analysis of the infrared images. More importantly, the IR images will help us understand transient heating in a ceramic material from the scientific standpoint. With the improved IR imaging ABB and ORNL will employ the IR system to visualize manufacturing defects that could not be detected otherwise. The proposed on-site tests at ABB Power Technology & Development processing facility will identify the defects and also allow quick adjustments to be made since the resulting products can be inspected immediately. ABB matched the DOE $50K funding with $50K funds-in to ORNL. ABB also provided about $75K in-kind effort for on-site testing, and R&D to improve the fabrication process.« less

  20. Electronic structure of transition metal-cysteine complexes from X-ray absorption spectroscopy.

    PubMed

    Leung, Bonnie O; Jalilehvand, Farideh; Szilagyi, Robert K

    2008-04-17

    The electronic structures of HgII, NiII, CrIII, and MoV complexes with cysteine were investigated by sulfur K-edge X-ray absorption near-edge structure (XANES) spectroscopy and density functional theory. The covalency in the metal-sulfur bond was determined by analyzing the intensities of the electric-dipole allowed pre-edge features appearing in the XANES spectra below the ionization threshold. Because of the well-defined structures of the selected cysteine complexes, the current work provides a reference set for further sulfur K-edge XAS studies of bioinorganic active sites with transition metal-sulfur bonds from cysteine residues as well as more complex coordination compounds with thiolate ligands.

  1. An Evaluation Method of Equipment Reliability Configuration Management

    NASA Astrophysics Data System (ADS)

    Wang, Wei; Feng, Weijia; Zhang, Wei; Li, Yuan

    2018-01-01

    At present, many equipment development companies have been aware of the great significance of reliability of the equipment development. But, due to the lack of effective management evaluation method, it is very difficult for the equipment development company to manage its own reliability work. Evaluation method of equipment reliability configuration management is to determine the reliability management capabilities of equipment development company. Reliability is not only designed, but also managed to achieve. This paper evaluates the reliability management capabilities by reliability configuration capability maturity model(RCM-CMM) evaluation method.

  2. The Microcode for the Control Processor of the ARO (Array Oriented Processor) Array Processor.

    DTIC Science & Technology

    1983-08-01

    oiNi .TADDR=DBASE+MODE" 4CONT ŕWAfT’ FOR MEM, MORE", MOV) ,DRO BSX "S IGN EXT, MORE" SADD D FLDSEI,(6,3),IMN TADT)R=5+ 1 JMP I NDE-’XEI) "JU> IP ’ T1...JDTV1: YIP DIVI; TDIV2: Y,’ IP DIV2; JASHII: JMP ASHI; 4 JASH2: JMP AS112; JXOR1: YIP XDRI; JXOR2: YIP XOR2; JSOB: JMP SOB; JBPL: JMP BPL; JBMI: YIP BMI;0...JBHI: JMP BHill JBLOS: J! IP BLOS; JBVC: YIP BVC; JBWS: JMP BVS; JBCC: JMP BCC; JBCS: YIP BCS; JEMT: YIP EMT; JTRAP: YIP TRAPQ; JCLR6: YIP CLR6; JCOII

  3. Fault Location Based on Synchronized Measurements: A Comprehensive Survey

    PubMed Central

    Al-Mohammed, A. H.; Abido, M. A.

    2014-01-01

    This paper presents a comprehensive survey on transmission and distribution fault location algorithms that utilize synchronized measurements. Algorithms based on two-end synchronized measurements and fault location algorithms on three-terminal and multiterminal lines are reviewed. Series capacitors equipped with metal oxide varistors (MOVs), when set on a transmission line, create certain problems for line fault locators and, therefore, fault location on series-compensated lines is discussed. The paper reports the work carried out on adaptive fault location algorithms aiming at achieving better fault location accuracy. Work associated with fault location on power system networks, although limited, is also summarized. Additionally, the nonstandard high-frequency-related fault location techniques based on wavelet transform are discussed. Finally, the paper highlights the area for future research. PMID:24701191

  4. Porous inorganic capsules in action: modelling transmembrane cation-transport parameter-dependence based on water as vehicle.

    PubMed

    Haupt, Erhard T K; Wontorra, Claudia; Rehder, Dieter; Müller, Achim

    2005-08-21

    Insight into basic principles of cation transport through "molecular channels", and especially details of the related fundamental H2O vehicle function, could be obtained via7Li NMR studies of the Li+ uptake/release processes by the unique porous nanocapsule [{(MoVI)MoVI5O21(H2O)6}12{MoV2O4(SO4)}30]72- which behaves as a semi-permeable inorganic membrane open for H2O and small cations; channel traffic as well as internal cavity distribution processes show a strong dependence on "environmental" effects such as exerted by solvent properties, the amount of water present, and competing complexing ligands, and end up in a complex equilibrium situation as in biological leak channels.

  5. A study on reliability of power customer in distribution network

    NASA Astrophysics Data System (ADS)

    Liu, Liyuan; Ouyang, Sen; Chen, Danling; Ma, Shaohua; Wang, Xin

    2017-05-01

    The existing power supply reliability index system is oriented to power system without considering actual electricity availability in customer side. In addition, it is unable to reflect outage or customer’s equipment shutdown caused by instantaneous interruption and power quality problem. This paper thus makes a systematic study on reliability of power customer. By comparing with power supply reliability, reliability of power customer is defined and extracted its evaluation requirements. An indexes system, consisting of seven customer indexes and two contrast indexes, are designed to describe reliability of power customer from continuity and availability. In order to comprehensively and quantitatively evaluate reliability of power customer in distribution networks, reliability evaluation method is proposed based on improved entropy method and the punishment weighting principle. Practical application has proved that reliability index system and evaluation method for power customer is reasonable and effective.

  6. Study on evaluation of construction reliability for engineering project based on fuzzy language operator

    NASA Astrophysics Data System (ADS)

    Shi, Yu-Fang; Ma, Yi-Yi; Song, Ping-Ping

    2018-03-01

    System Reliability Theory is a research hotspot of management science and system engineering in recent years, and construction reliability is useful for quantitative evaluation of project management level. According to reliability theory and target system of engineering project management, the defination of construction reliability appears. Based on fuzzy mathematics theory and language operator, value space of construction reliability is divided into seven fuzzy subsets and correspondingly, seven membership function and fuzzy evaluation intervals are got with the operation of language operator, which provides the basis of corresponding method and parameter for the evaluation of construction reliability. This method is proved to be scientific and reasonable for construction condition and an useful attempt for theory and method research of engineering project system reliability.

  7. Improving reliability of a residency interview process.

    PubMed

    Peeters, Michael J; Serres, Michelle L; Gundrum, Todd E

    2013-10-14

    To improve the reliability and discrimination of a pharmacy resident interview evaluation form, and thereby improve the reliability of the interview process. In phase 1 of the study, authors used a Many-Facet Rasch Measurement model to optimize an existing evaluation form for reliability and discrimination. In phase 2, interviewer pairs used the modified evaluation form within 4 separate interview stations. In phase 3, 8 interviewers individually-evaluated each candidate in one-on-one interviews. In phase 1, the evaluation form had a reliability of 0.98 with person separation of 6.56; reproducibly, the form separated applicants into 6 distinct groups. Using that form in phase 2 and 3, our largest variation source was candidates, while content specificity was the next largest variation source. The phase 2 g-coefficient was 0.787, while confirmatory phase 3 was 0.922. Process reliability improved with more stations despite fewer interviewers per station-impact of content specificity was greatly reduced with more interview stations. A more reliable, discriminating evaluation form was developed to evaluate candidates during resident interviews, and a process was designed that reduced the impact from content specificity.

  8. Claims about the Reliability of Student Evaluations of Instruction: The Ecological Fallacy Rides Again

    ERIC Educational Resources Information Center

    Morley, Donald D.

    2012-01-01

    The vast majority of the research on student evaluation of instruction has assessed the reliability of groups of courses and yielded either a single reliability coefficient for the entire group, or grouped reliability coefficients for each student evaluation of teaching (SET) item. This manuscript argues that these practices constitute a form of…

  9. A fully human chimeric antigen receptor with potent activity against cancer cells but reduced risk for off-tumor toxicity

    PubMed Central

    Song, De-Gang; Ye, Qunrui; Poussin, Mathilde; Liu, Lin; Figini, Mariangela; Powell, Daniel J.

    2015-01-01

    Chimeric antigen receptors (CARs) can redirect T cells against antigen-expressing tumors in an HLA-independent manner. To date, various CARs have been constructed using mouse single chain antibody variable fragments (scFvs) of high affinity that are immunogenic in humans and have the potential to mediate “on-target” toxicity. Here, we developed and evaluated a fully human CAR comprised of the human C4 folate receptor-alpha (αFR)-specific scFv coupled to intracellular T cell signaling domains. Human T cells transduced to express the C4 CAR specifically secreted proinflammatory cytokine and exerted cytolytic functions when cultured with αFR-expressing tumors in vitro. Adoptive transfer of C4 CAR T cells mediated the regression of large, established human ovarian cancer in a xenogeneic mouse model. Relative to a murine MOv19 scFv-based αFR CAR, C4 CAR T cells mediated comparable cytotoxic tumor activity in vitro and in vivo but had lower affinity for αFR protein and exhibited reduced recognition of normal cells expressing low levels of αFR. Thus, T cells expressing a fully human CAR of intermediate affinity can efficiently kill antigen-expressing tumors in vitro and in vivo and may overcome issues of transgene immunogenicity and “on-target off-tumor” toxicity that plague trials utilizing CARs containing mouse-derived, high affinity scFvs. PMID:26101914

  10. A self-powered kinesin-microtubule system for smart cargo delivery

    NASA Astrophysics Data System (ADS)

    Jia, Yi; Dong, Weiguang; Feng, Xiyun; Li, Jieling; Li, Junbai

    2014-11-01

    A smart self-powered cargo delivery system that is composed of creatine phosphate kinase (CPK) microspheres, kinesins and microtubules is demonstrated. The CPK microsphere not only acts as an ATP generation and buffering system, but also as a carrier for cargo transport, thus realizing the easy loading and self-powered delivery of cargos at the same time.A smart self-powered cargo delivery system that is composed of creatine phosphate kinase (CPK) microspheres, kinesins and microtubules is demonstrated. The CPK microsphere not only acts as an ATP generation and buffering system, but also as a carrier for cargo transport, thus realizing the easy loading and self-powered delivery of cargos at the same time. Electronic supplementary information (ESI) available: Experimental details, Fig. S1-S4, and Mov. S1-S6. See DOI: 10.1039/c4nr04454a

  11. Monitoring the growth of polyoxomolybdate nanoparticles in suspension by flow field-flow fractionation.

    PubMed

    Chen, Bailin; Jiang, Huijian; Zhu, Yan; Cammers, Arthur; Selegue, John P

    2005-03-30

    We follow the evolution of polyoxomolybdate nanoparticles in suspensions derived from the keplerate (NH4)42[MoVI72MoV60O372(CH3CO2)30(H2O)72].ca..300H2O.ca..10CH3CO2NH4 ({Mo132}) by flow field-flow fractionation (FlFFF) to monitor the particle-size distribution in situ, atomic force and high-resolution transmission electron microscopy (AFM, SEM, and HRTEM) to confirm particle sizes, inductively coupled plasma-optical emission spectrometry (ICP-OES) to determine the Mo content of the FlFFF-separated fractions, and UV/visible spectroscopy to confirm the identity of the species in suspension. We observe the formation of 3-75-nm polyoxomolybdate particles in suspension and the dynamic growth of {Mo132} crystals.

  12. Evaluation of Reliability Coefficients for Two-Level Models via Latent Variable Analysis

    ERIC Educational Resources Information Center

    Raykov, Tenko; Penev, Spiridon

    2010-01-01

    A latent variable analysis procedure for evaluation of reliability coefficients for 2-level models is outlined. The method provides point and interval estimates of group means' reliability, overall reliability of means, and conditional reliability. In addition, the approach can be used to test simple hypotheses about these parameters. The…

  13. Reliability Evaluation of Machine Center Components Based on Cascading Failure Analysis

    NASA Astrophysics Data System (ADS)

    Zhang, Ying-Zhi; Liu, Jin-Tong; Shen, Gui-Xiang; Long, Zhe; Sun, Shu-Guang

    2017-07-01

    In order to rectify the problems that the component reliability model exhibits deviation, and the evaluation result is low due to the overlook of failure propagation in traditional reliability evaluation of machine center components, a new reliability evaluation method based on cascading failure analysis and the failure influenced degree assessment is proposed. A direct graph model of cascading failure among components is established according to cascading failure mechanism analysis and graph theory. The failure influenced degrees of the system components are assessed by the adjacency matrix and its transposition, combined with the Pagerank algorithm. Based on the comprehensive failure probability function and total probability formula, the inherent failure probability function is determined to realize the reliability evaluation of the system components. Finally, the method is applied to a machine center, it shows the following: 1) The reliability evaluation values of the proposed method are at least 2.5% higher than those of the traditional method; 2) The difference between the comprehensive and inherent reliability of the system component presents a positive correlation with the failure influenced degree of the system component, which provides a theoretical basis for reliability allocation of machine center system.

  14. A New Tool for Nutrition App Quality Evaluation (AQEL): Development, Validation, and Reliability Testing

    PubMed Central

    Huang, Wenhao; Chapman-Novakofski, Karen M

    2017-01-01

    Background The extensive availability and increasing use of mobile apps for nutrition-based health interventions makes evaluation of the quality of these apps crucial for integration of apps into nutritional counseling. Objective The goal of this research was the development, validation, and reliability testing of the app quality evaluation (AQEL) tool, an instrument for evaluating apps’ educational quality and technical functionality. Methods Items for evaluating app quality were adapted from website evaluations, with additional items added to evaluate the specific characteristics of apps, resulting in 79 initial items. Expert panels of nutrition and technology professionals and app users reviewed items for face and content validation. After recommended revisions, nutrition experts completed a second AQEL review to ensure clarity. On the basis of 150 sets of responses using the revised AQEL, principal component analysis was completed, reducing AQEL into 5 factors that underwent reliability testing, including internal consistency, split-half reliability, test-retest reliability, and interrater reliability (IRR). Two additional modifiable constructs for evaluating apps based on the age and needs of the target audience as selected by the evaluator were also tested for construct reliability. IRR testing using intraclass correlations (ICC) with all 7 constructs was conducted, with 15 dietitians evaluating one app. Results Development and validation resulted in the 51-item AQEL. These were reduced to 25 items in 5 factors after principal component analysis, plus 9 modifiable items in two constructs that were not included in principal component analysis. Internal consistency and split-half reliability of the following constructs derived from principal components analysis was good (Cronbach alpha >.80, Spearman-Brown coefficient >.80): behavior change potential, support of knowledge acquisition, app function, and skill development. App purpose split half-reliability was .65. Test-retest reliability showed no significant change over time (P>.05) for all but skill development (P=.001). Construct reliability was good for items assessing age appropriateness of apps for children, teens, and a general audience. In addition, construct reliability was acceptable for assessing app appropriateness for various target audiences (Cronbach alpha >.70). For the 5 main factors, ICC (1,k) was >.80, with a P value of <.05. When 15 nutrition professionals evaluated one app, ICC (2,15) was .98, with a P value of <.001 for all 7 constructs when the modifiable items were specified for adults seeking weight loss support. Conclusions Our preliminary effort shows that AQEL is a valid, reliable instrument for evaluating nutrition apps’ qualities for clinical interventions by nutrition clinicians, educators, and researchers. Further efforts in validating AQEL in various contexts are needed. PMID:29079554

  15. Reliability Evaluation and Improvement Approach of Chemical Production Man - Machine - Environment System

    NASA Astrophysics Data System (ADS)

    Miao, Yongchun; Kang, Rongxue; Chen, Xuefeng

    2017-12-01

    In recent years, with the gradual extension of reliability research, the study of production system reliability has become the hot topic in various industries. Man-machine-environment system is a complex system composed of human factors, machinery equipment and environment. The reliability of individual factor must be analyzed in order to gradually transit to the research of three-factor reliability. Meanwhile, the dynamic relationship among man-machine-environment should be considered to establish an effective blurry evaluation mechanism to truly and effectively analyze the reliability of such systems. In this paper, based on the system engineering, fuzzy theory, reliability theory, human error, environmental impact and machinery equipment failure theory, the reliabilities of human factor, machinery equipment and environment of some chemical production system were studied by the method of fuzzy evaluation. At last, the reliability of man-machine-environment system was calculated to obtain the weighted result, which indicated that the reliability value of this chemical production system was 86.29. Through the given evaluation domain it can be seen that the reliability of man-machine-environment integrated system is in a good status, and the effective measures for further improvement were proposed according to the fuzzy calculation results.

  16. Improving Reliability of a Residency Interview Process

    PubMed Central

    Serres, Michelle L.; Gundrum, Todd E.

    2013-01-01

    Objective. To improve the reliability and discrimination of a pharmacy resident interview evaluation form, and thereby improve the reliability of the interview process. Methods. In phase 1 of the study, authors used a Many-Facet Rasch Measurement model to optimize an existing evaluation form for reliability and discrimination. In phase 2, interviewer pairs used the modified evaluation form within 4 separate interview stations. In phase 3, 8 interviewers individually-evaluated each candidate in one-on-one interviews. Results. In phase 1, the evaluation form had a reliability of 0.98 with person separation of 6.56; reproducibly, the form separated applicants into 6 distinct groups. Using that form in phase 2 and 3, our largest variation source was candidates, while content specificity was the next largest variation source. The phase 2 g-coefficient was 0.787, while confirmatory phase 3 was 0.922. Process reliability improved with more stations despite fewer interviewers per station—impact of content specificity was greatly reduced with more interview stations. Conclusion. A more reliable, discriminating evaluation form was developed to evaluate candidates during resident interviews, and a process was designed that reduced the impact from content specificity. PMID:24159209

  17. Indices of Paraspinal Muscles Degeneration: Reliability and Association With Facet Joint Osteoarthritis: Feasibility Study.

    PubMed

    Kalichman, Leonid; Klindukhov, Alexander; Li, Ling; Linov, Lina

    2016-11-01

    A reliability and cross-sectional observational study. To introduce a scoring system for visible fat infiltration in paraspinal muscles; to evaluate intertester and intratester reliability of this system and its relationship with indices of muscle density; to evaluate the association between indices of paraspinal muscle degeneration and facet joint osteoarthritis. Current evidence suggests that the paraspinal muscles degeneration is associated with low back pain, facet joint osteoarthritis, spondylolisthesis, and degenerative disc disease. However, the evaluation of paraspinal muscles on computed tomography is not radiological routine, probably because of absence of simple and reliable indices of paraspinal degeneration. One hundred fifty consecutive computed tomography scans of the lower back (N=75) or abdomen (N=75) were evaluated. Mean radiographic density (in Hounsfield units) and SD of the density of multifidus and erector spinae were evaluated at the L4-L5 spinal level. A new index of muscle degeneration, radiographic density ratio=muscle density/SD of density, was calculated. To evaluate the visible fat infiltration in paraspinal muscles, we proposed a 3-graded scoring system. The prevalence of facet joint osteoarthritis was also evaluated. Intraclass correlation and κ statistics were used to evaluate inter-rater and intra-rater reliability. Logistic regression examined the association between paraspinal muscle indices and facet joint osteoarthritis. Intra-rater reliability for fat infiltration score (κ) ranged between 0.87 and 0.92; inter-rater reliability between 0.70 and 0.81. Intra-rater reliability (intraclass correlation) for mean density of paraspinal muscles ranged between 0.96 and 0.99, inter-rater reliability between 0.95 and 0.99; SD intra-rater reliability ranged between 0.82 and 0.91, inter-rater reliability between 0.80 and 0.89. Significant associations (P<0.01) were found between facet joint osteoarthritis, fat infiltration score, and radiographic density ratio. Two suggested indices of paraspinal muscle degeneration showed excellent reliability and were significantly associated with facet joint osteoarthritis. Additional studies are needed to evaluate the associations with other spinal degeneration features and low back pain.

  18. A study on the real-time reliability of on-board equipment of train control system

    NASA Astrophysics Data System (ADS)

    Zhang, Yong; Li, Shiwei

    2018-05-01

    Real-time reliability evaluation is conducive to establishing a condition based maintenance system for the purpose of guaranteeing continuous train operation. According to the inherent characteristics of the on-board equipment, the connotation of reliability evaluation of on-board equipment is defined and the evaluation index of real-time reliability is provided in this paper. From the perspective of methodology and practical application, the real-time reliability of the on-board equipment is discussed in detail, and the method of evaluating the realtime reliability of on-board equipment at component level based on Hidden Markov Model (HMM) is proposed. In this method the performance degradation data is used directly to realize the accurate perception of the hidden state transition process of on-board equipment, which can achieve a better description of the real-time reliability of the equipment.

  19. Interrater and intrarater reliability of FDI criteria applied to photographs of posterior tooth-colored restorations.

    PubMed

    Kim, Dohyun; Ahn, So-Yeon; Kim, Junyoung; Park, Sung-Ho

    2017-07-01

    Since 2007, the FDI World Dental Federation (FDI) criteria have been used for the clinical evaluation of dental restorations. However, the reliability of the FDI criteria has not been sufficiently addressed. The purpose of this study was to assess and compare the interrater and intrarater reliability of the FDI criteria by evaluating posterior tooth-colored restorations photographically. A total of 160 clinical photographs of posterior tooth-colored restorations were evaluated independently by 5 raters with 9 of the FDI criteria suitable for photographic evaluation. The raters recorded the score of each restoration by using 5 grades, and the score was dichotomized into the clinical evaluation scores. After 1 month, 2 of the raters reevaluated the same set of 160 photographs in random order. To estimate the interrater reliability among the 5 raters, the proportion of agreement was calculated, and the Fleiss multirater kappa statistic was used. For the intrarater reliability, the proportion of agreement was calculated, and the Cohen standard kappa statistic was used for each of the 2 raters. The interrater proportion of agreement was 0.41 to 0.57, and the kappa value was 0.09 to 0.39. Overall, the intrarater reliability was higher than the interrater reliability, and rater 1 demonstrated higher intrarater reliability than rater 2. The proportion of agreement and kappa values increased when the 5 scores were dichotomized. The reliability was relatively lower for the esthetic properties compared with the functional or biological properties. Within the limitations of this study, the FDI criteria presented slight to fair interrater reliability and fair to excellent intrarater reliability in the photographic evaluation of posterior tooth-colored restorations. The reliability was improved by simplifying the evaluation scores. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  20. Are Validity and Reliability "Relevant" in Qualitative Evaluation Research?

    ERIC Educational Resources Information Center

    Goodwin, Laura D.; Goodwin, William L.

    1984-01-01

    The views of prominant qualitative methodologists on the appropriateness of validity and reliability estimation for the measurement strategies employed in qualitative evaluations are summarized. A case is made for the relevance of validity and reliability estimation. Definitions of validity and reliability for qualitative measurement are presented…

  1. Evaluation of reliability modeling tools for advanced fault tolerant systems

    NASA Technical Reports Server (NTRS)

    Baker, Robert; Scheper, Charlotte

    1986-01-01

    The Computer Aided Reliability Estimation (CARE III) and Automated Reliability Interactice Estimation System (ARIES 82) reliability tools for application to advanced fault tolerance aerospace systems were evaluated. To determine reliability modeling requirements, the evaluation focused on the Draper Laboratories' Advanced Information Processing System (AIPS) architecture as an example architecture for fault tolerance aerospace systems. Advantages and limitations were identified for each reliability evaluation tool. The CARE III program was designed primarily for analyzing ultrareliable flight control systems. The ARIES 82 program's primary use was to support university research and teaching. Both CARE III and ARIES 82 were not suited for determining the reliability of complex nodal networks of the type used to interconnect processing sites in the AIPS architecture. It was concluded that ARIES was not suitable for modeling advanced fault tolerant systems. It was further concluded that subject to some limitations (the difficulty in modeling systems with unpowered spare modules, systems where equipment maintenance must be considered, systems where failure depends on the sequence in which faults occurred, and systems where multiple faults greater than a double near coincident faults must be considered), CARE III is best suited for evaluating the reliability of advanced tolerant systems for air transport.

  2. Blinded evaluation of interrater reliability of an operative competency assessment tool for direct laryngoscopy and rigid bronchoscopy.

    PubMed

    Ishman, Stacey L; Benke, James R; Johnson, Kaalan Erik; Zur, Karen B; Jacobs, Ian N; Thorne, Marc C; Brown, David J; Lin, Sandra Y; Bhatti, Nasir; Deutsch, Ellen S

    2012-10-01

    OBJECTIVES To confirm interrater reliability using blinded evaluation of a skills-assessment instrument to assess the surgical performance of resident and fellow trainees performing pediatric direct laryngoscopy and rigid bronchoscopy in simulated models. DESIGN Prospective, paired, blinded observational validation study. SUBJECTS Paired observers from multiple institutions simultaneously evaluated residents and fellows who were performing surgery in an animal laboratory or using high-fidelity manikins. The evaluators had no previous affiliation with the residents and fellows and did not know their year of training. INTERVENTIONS One- and 2-page versions of an objective structured assessment of technical skills (OSATS) assessment instrument composed of global and a task-specific surgical items were used to evaluate surgical performance. RESULTS Fifty-two evaluations were completed by 17 attending evaluators. The instrument agreement for the 2-page assessment was 71.4% when measured as a binary variable (ie, competent vs not competent) (κ = 0.38; P = .08). Evaluation as a continuous variable revealed a 42.9% percentage agreement (κ = 0.18; P = .14). The intraclass correlation was 0.53, considered substantial/good interrater reliability (69% reliable). For the 1-page instrument, agreement was 77.4% when measured as a binary variable (κ = 0.53, P = .0015). Agreement when evaluated as a continuous measure was 71.0% (κ = 0.54, P < .001). The intraclass correlation was 0.73, considered high interrater reliability (85% reliable). CONCLUSIONS The OSATS assessment instrument is an effective tool for evaluating surgical performance among trainees with acceptable interrater reliability in a simulator setting. Reliability was good for both the 1- and 2-page OSATS checklists, and both serve as excellent tools to provide immediate formative feedback on operational competency.

  3. A New Tool for Nutrition App Quality Evaluation (AQEL): Development, Validation, and Reliability Testing.

    PubMed

    DiFilippo, Kristen Nicole; Huang, Wenhao; Chapman-Novakofski, Karen M

    2017-10-27

    The extensive availability and increasing use of mobile apps for nutrition-based health interventions makes evaluation of the quality of these apps crucial for integration of apps into nutritional counseling. The goal of this research was the development, validation, and reliability testing of the app quality evaluation (AQEL) tool, an instrument for evaluating apps' educational quality and technical functionality. Items for evaluating app quality were adapted from website evaluations, with additional items added to evaluate the specific characteristics of apps, resulting in 79 initial items. Expert panels of nutrition and technology professionals and app users reviewed items for face and content validation. After recommended revisions, nutrition experts completed a second AQEL review to ensure clarity. On the basis of 150 sets of responses using the revised AQEL, principal component analysis was completed, reducing AQEL into 5 factors that underwent reliability testing, including internal consistency, split-half reliability, test-retest reliability, and interrater reliability (IRR). Two additional modifiable constructs for evaluating apps based on the age and needs of the target audience as selected by the evaluator were also tested for construct reliability. IRR testing using intraclass correlations (ICC) with all 7 constructs was conducted, with 15 dietitians evaluating one app. Development and validation resulted in the 51-item AQEL. These were reduced to 25 items in 5 factors after principal component analysis, plus 9 modifiable items in two constructs that were not included in principal component analysis. Internal consistency and split-half reliability of the following constructs derived from principal components analysis was good (Cronbach alpha >.80, Spearman-Brown coefficient >.80): behavior change potential, support of knowledge acquisition, app function, and skill development. App purpose split half-reliability was .65. Test-retest reliability showed no significant change over time (P>.05) for all but skill development (P=.001). Construct reliability was good for items assessing age appropriateness of apps for children, teens, and a general audience. In addition, construct reliability was acceptable for assessing app appropriateness for various target audiences (Cronbach alpha >.70). For the 5 main factors, ICC (1,k) was >.80, with a P value of <.05. When 15 nutrition professionals evaluated one app, ICC (2,15) was .98, with a P value of <.001 for all 7 constructs when the modifiable items were specified for adults seeking weight loss support. Our preliminary effort shows that AQEL is a valid, reliable instrument for evaluating nutrition apps' qualities for clinical interventions by nutrition clinicians, educators, and researchers. Further efforts in validating AQEL in various contexts are needed. ©Kristen Nicole DiFilippo, Wenhao Huang, Karen M. Chapman-Novakofski. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 27.10.2017.

  4. SPSS Macros for Assessing the Reliability and Agreement of Student Evaluations of Teaching

    ERIC Educational Resources Information Center

    Morley, Donald D.

    2009-01-01

    This article reports and demonstrates two SPSS macros for calculating Krippendorff's alpha and intraclass reliability coefficients in repetitive situations where numerous coefficients are needed. Specifically, the reported SPSS macros were used to evaluate the interrater agreement and reliability of student evaluations of teaching in thousands of…

  5. Evaluation methodologies for an advanced information processing system

    NASA Technical Reports Server (NTRS)

    Schabowsky, R. S., Jr.; Gai, E.; Walker, B. K.; Lala, J. H.; Motyka, P.

    1984-01-01

    The system concept and requirements for an Advanced Information Processing System (AIPS) are briefly described, but the emphasis of this paper is on the evaluation methodologies being developed and utilized in the AIPS program. The evaluation tasks include hardware reliability, maintainability and availability, software reliability, performance, and performability. Hardware RMA and software reliability are addressed with Markov modeling techniques. The performance analysis for AIPS is based on queueing theory. Performability is a measure of merit which combines system reliability and performance measures. The probability laws of the performance measures are obtained from the Markov reliability models. Scalar functions of this law such as the mean and variance provide measures of merit in the AIPS performability evaluations.

  6. Covariate-free and Covariate-dependent Reliability.

    PubMed

    Bentler, Peter M

    2016-12-01

    Classical test theory reliability coefficients are said to be population specific. Reliability generalization, a meta-analysis method, is the main procedure for evaluating the stability of reliability coefficients across populations. A new approach is developed to evaluate the degree of invariance of reliability coefficients to population characteristics. Factor or common variance of a reliability measure is partitioned into parts that are, and are not, influenced by control variables, resulting in a partition of reliability into a covariate-dependent and a covariate-free part. The approach can be implemented in a single sample and can be applied to a variety of reliability coefficients.

  7. A Review on VSC-HVDC Reliability Modeling and Evaluation Techniques

    NASA Astrophysics Data System (ADS)

    Shen, L.; Tang, Q.; Li, T.; Wang, Y.; Song, F.

    2017-05-01

    With the fast development of power electronics, voltage-source converter (VSC) HVDC technology presents cost-effective ways for bulk power transmission. An increasing number of VSC-HVDC projects has been installed worldwide. Their reliability affects the profitability of the system and therefore has a major impact on the potential investors. In this paper, an overview of the recent advances in the area of reliability evaluation for VSC-HVDC systems is provided. Taken into account the latest multi-level converter topology, the VSC-HVDC system is categorized into several sub-systems and the reliability data for the key components is discussed based on sources with academic and industrial backgrounds. The development of reliability evaluation methodologies is reviewed and the issues surrounding the different computation approaches are briefly analysed. A general VSC-HVDC reliability evaluation procedure is illustrated in this paper.

  8. Dynamic MRI to quantify musculoskeletal motion: A systematic review of concurrent validity and reliability, and perspectives for evaluation of musculoskeletal disorders.

    PubMed

    Borotikar, Bhushan; Lempereur, Mathieu; Lelievre, Mathieu; Burdin, Valérie; Ben Salem, Douraied; Brochard, Sylvain

    2017-01-01

    To report evidence for the concurrent validity and reliability of dynamic MRI techniques to evaluate in vivo joint and muscle mechanics, and to propose recommendations for their use in the assessment of normal and impaired musculoskeletal function. The search was conducted on articles published in Web of science, PubMed, Scopus, Academic search Premier, and Cochrane Library between 1990 and August 2017. Studies that reported the concurrent validity and/or reliability of dynamic MRI techniques for in vivo evaluation of joint or muscle mechanics were included after assessment by two independent reviewers. Selected articles were assessed using an adapted quality assessment tool and a data extraction process. Results for concurrent validity and reliability were categorized as poor, moderate, or excellent. Twenty articles fulfilled the inclusion criteria with a mean quality assessment score of 66% (±10.4%). Concurrent validity and/or reliability of eight dynamic MRI techniques were reported, with the knee being the most evaluated joint (seven studies). Moderate to excellent concurrent validity and reliability were reported for seven out of eight dynamic MRI techniques. Cine phase contrast and real-time MRI appeared to be the most valid and reliable techniques to evaluate joint motion, and spin tag for muscle motion. Dynamic MRI techniques are promising for the in vivo evaluation of musculoskeletal mechanics; however results should be evaluated with caution since validity and reliability have not been determined for all joints and muscles, nor for many pathological conditions.

  9. Revised Space Groups for Three Molybdenum(V) Phosphate Compounds

    NASA Astrophysics Data System (ADS)

    Leclaire, A.; Borel, M. M.; Guesdon, A.; Marsh, Richard E.

    2001-06-01

    The space groups of three previously described Mo(V) phosphate structures are revised. (1) δ-KMo2P3O13, originally reported as triclinic, Poverline1, is revised to monoclinic, C2/c; it is identical to the compound previously identified as K4Mo8P12O52. (2) The compound formulated as [Mo12CdP8O50(OH)12]Cd [N(CH3)4]2(H3O)6·5H2O, originally described as monoclinic, Pn, is revised to P21/n (also monoclinic). (3) Rb3O2(MoO)4(PO4)4, originally reported as orthorhombic, C2221, is revised to tetragonal, P43212. The general descriptions of the structures are unchanged; however, for compound 2 the revision involves the addition of a center of symmetry and, as a result, there are significant changes in the interatomic distances and angles.

  10. Effect of CeO2 on TiC Morphology in Ni-Based Composite Coating

    NASA Astrophysics Data System (ADS)

    Cai, Yangchuan; Luo, Zhen; Chen, Yao

    2018-03-01

    The TiC/Ni composite coating with different content of CeO2 was fabricated on the Cr12MoV steel by laser cladding. The microstructure of cladding layers with the different content of CeO2 from the bottom to the surface is columnar crystal, cellular crystal, and equiaxed crystal. When the content of CeO2 is 0 %, the cladding layer has a coarse and nonuniform microstructure and TiC particles gathering in the cladding layer, and then the wear resistance was reduced. Appropriate rare-earth elements refined and homogenised the microstructure and enhanced the content of carbides, precipitated TiC particles and original TiC particles were spheroidised and refined, the wear resistance of the cladding layer was improved significantly. Excessive rare-earth elements polluted the grain boundaries and made the excessive burning loss of TiC particles that reduced the wear resistance of the cladding layer.

  11. Data requirements to model creep in 9Cr-1Mo-V steel

    NASA Technical Reports Server (NTRS)

    Swindeman, R. W.

    1988-01-01

    Models for creep behavior are helpful in predicting response of components experiencing stress redistributions due to cyclic loads, and often the analyst would like information that correlates strain rate with history assuming simple hardening rules such as those based on time or strain. On the one hand, much progress has been made in the development of unified constitutive equations that include both hardening and softening through the introduction of state variables whose evolutions are history dependent. Although it is difficult to estimate specific data requirements for general application, there are several simple measurements that can be made in the course of creep testing and results reported in data bases. The issue is whether or not such data could be helpful in developing unified equations, and, if so, how should such data be reported. Data produced on a martensitic 9Cr-1Mo-V-Nb steel were examined with these issues in mind.

  12. Performance Evaluation of Reliable Multicast Protocol for Checkout and Launch Control Systems

    NASA Technical Reports Server (NTRS)

    Shu, Wei Wennie; Porter, John

    2000-01-01

    The overall objective of this project is to study reliability and performance of Real Time Critical Network (RTCN) for checkout and launch control systems (CLCS). The major tasks include reliability and performance evaluation of Reliable Multicast (RM) package and fault tolerance analysis and design of dual redundant network architecture.

  13. Students' Evaluation Strategies in a Web Research Task: Are They Sensitive to Relevance and Reliability?

    ERIC Educational Resources Information Center

    Rodicio, Héctor García

    2015-01-01

    When searching and using resources on the Web, students have to evaluate Web pages in terms of relevance and reliability. This evaluation can be done in a more or less systematic way, by either considering deep or superficial cues of relevance and reliability. The goal of this study was to examine how systematic students are when evaluating Web…

  14. The Number of Feedbacks Needed for Reliable Evaluation. A Multilevel Analysis of the Reliability, Stability and Generalisability of Students' Evaluation of Teaching

    ERIC Educational Resources Information Center

    Rantanen, Pekka

    2013-01-01

    A multilevel analysis approach was used to analyse students' evaluation of teaching (SET). The low value of inter-rater reliability stresses that any solid conclusions on teaching cannot be made on the basis of single feedbacks. To assess a teacher's general teaching effectiveness, one needs to evaluate four randomly chosen course implementations.…

  15. Assessing the Reliability of Student Evaluations of Teaching: Choosing the Right Coefficient

    ERIC Educational Resources Information Center

    Morley, Donald

    2014-01-01

    Many of the studies used to support the claim that student evaluations of teaching are reliable measures of teaching effectiveness have frequently calculated inappropriate reliability coefficients. This paper points to three coefficients that would be appropriate depending on if student evaluations were used for formative or summative purposes.…

  16. Reliable and valid tools for measuring surgeons' teaching performance: residents' vs. self evaluation.

    PubMed

    Boerebach, Benjamin C M; Arah, Onyebuchi A; Busch, Olivier R C; Lombarts, Kiki M J M H

    2012-01-01

    In surgical education, there is a need for educational performance evaluation tools that yield reliable and valid data. This paper describes the development and validation of robust evaluation tools that provide surgeons with insight into their clinical teaching performance. We investigated (1) the reliability and validity of 2 tools for evaluating the teaching performance of attending surgeons in residency training programs, and (2) whether surgeons' self evaluation correlated with the residents' evaluation of those surgeons. We surveyed 343 surgeons and 320 residents as part of a multicenter prospective cohort study of faculty teaching performance in residency training programs. The reliability and validity of the SETQ (System for Evaluation Teaching Qualities) tools were studied using standard psychometric techniques. We then estimated the correlations between residents' and surgeons' evaluations. The response rate was 87% among surgeons and 84% among residents, yielding 2625 residents' evaluations and 302 self evaluations. The SETQ tools yielded reliable and valid data on 5 domains of surgical teaching performance, namely, learning climate, professional attitude towards residents, communication of goals, evaluation of residents, and feedback. The correlations between surgeons' self and residents' evaluations were low, with coefficients ranging from 0.03 for evaluation of residents to 0.18 for communication of goals. The SETQ tools for the evaluation of surgeons' teaching performance appear to yield reliable and valid data. The lack of strong correlations between surgeons' self and residents' evaluations suggest the need for using external feedback sources in informed self evaluation of surgeons. Copyright © 2012 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  17. Use of a structured functional evaluation process for independent medical evaluations of claimants presenting with disabling mental illness: rationale and design for a multi-center reliability study.

    PubMed

    Bachmann, Monica; de Boer, Wout; Schandelmaier, Stefan; Leibold, Andrea; Marelli, Renato; Jeger, Joerg; Hoffmann-Richter, Ulrike; Mager, Ralph; Schaad, Heinz; Zumbrunn, Thomas; Vogel, Nicole; Bänziger, Oskar; Busse, Jason W; Fischer, Katrin; Kunz, Regina

    2016-07-29

    Work capacity evaluations by independent medical experts are widely used to inform insurers whether injured or ill workers are capable of engaging in competitive employment. In many countries, evaluation processes lack a clearly structured approach, standardized instruments, and an explicit focus on claimants' functional abilities. Evaluation of subjective complaints, such as mental illness, present additional challenges in the determination of work capacity. We have therefore developed a process for functional evaluation of claimants with mental disorders which complements usual psychiatric evaluation. Here we report the design of a study to measure the reliability of our approach in determining work capacity among patients with mental illness applying for disability benefits. We will conduct a multi-center reliability study, in which 20 psychiatrists trained in our functional evaluation process will assess 30 claimants presenting with mental illness for eligibility to receive disability benefits [Reliability of Functional Evaluation in Psychiatry, RELY-study]. The functional evaluation process entails a five-step structured interview and a reporting instrument (Instrument of Functional Assessment in Psychiatry [IFAP]) to document the severity of work-related functional limitations. We will videotape all evaluations which will be viewed by three psychiatrists who will independently rate claimants' functional limitations. Our primary outcome measure is the evaluation of claimant's work capacity as a percentage (0 to 100 %), and our secondary outcomes are the 12 mental functions and 13 functional capacities assessed by the IFAP-instrument. Inter-rater reliability of four psychiatric experts will be explored using multilevel models to estimate the intraclass correlation coefficient (ICC). Additional analyses include subgroups according to mental disorder, the typicality of claimants, and claimant perceived fairness of the assessment process. We hypothesize that a structured functional approach will show moderate reliability (ICC ≥ 0.6) of psychiatric evaluation of work capacity. Enrollment of actual claimants with mental disorders referred for evaluation by disability/accident insurers will increase the external validity of our findings. Finding moderate levels of reliability, we will continue with a randomized trial to test the reliability of a structured functional approach versus evaluation-as-usual.

  18. Computer-Aided Reliability Estimation

    NASA Technical Reports Server (NTRS)

    Bavuso, S. J.; Stiffler, J. J.; Bryant, L. A.; Petersen, P. L.

    1986-01-01

    CARE III (Computer-Aided Reliability Estimation, Third Generation) helps estimate reliability of complex, redundant, fault-tolerant systems. Program specifically designed for evaluation of fault-tolerant avionics systems. However, CARE III general enough for use in evaluation of other systems as well.

  19. Reliability models: the influence of model specification in generation expansion planning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stremel, J.P.

    1982-10-01

    This paper is a critical evaluation of reliability methods used for generation expansion planning. It is shown that the methods for treating uncertainty are critical for determining the relative reliability value of expansion alternatives. It is also shown that the specification of the reliability model will not favor all expansion options equally. Consequently, the model is biased. In addition, reliability models should be augmented with an economic value of reliability (such as the cost of emergency procedures or energy not served). Generation expansion evaluations which ignore the economic value of excess reliability can be shown to be inconsistent. The conclusionsmore » are that, in general, a reliability model simplifies generation expansion planning evaluations. However, for a thorough analysis, the expansion options should be reviewed for candidates which may be unduly rejected because of the bias of the reliability model. And this implies that for a consistent formulation in an optimization framework, the reliability model should be replaced with a full economic optimization which includes the costs of emergency procedures and interruptions in the objective function.« less

  20. Construction and Evaluation of Reliability and Validity of Reasoning Ability Test

    ERIC Educational Resources Information Center

    Bhat, Mehraj A.

    2014-01-01

    This paper is based on the construction and evaluation of reliability and validity of reasoning ability test at secondary school students. In this paper an attempt was made to evaluate validity, reliability and to determine the appropriate standards to interpret the results of reasoning ability test. The test includes 45 items to measure six types…

  1. Field reliability of competency and sanity opinions: A systematic review and meta-analysis.

    PubMed

    Guarnera, Lucy A; Murrie, Daniel C

    2017-06-01

    We know surprisingly little about the interrater reliability of forensic psychological opinions, even though courts and other authorities have long called for known error rates for scientific procedures admitted as courtroom testimony. This is particularly true for opinions produced during routine practice in the field, even for some of the most common types of forensic evaluations-evaluations of adjudicative competency and legal sanity. To address this gap, we used meta-analytic procedures and study space methodology to systematically review studies that examined the interrater reliability-particularly the field reliability-of competency and sanity opinions. Of 59 identified studies, 9 addressed the field reliability of competency opinions and 8 addressed the field reliability of sanity opinions. These studies presented a wide range of reliability estimates; pairwise percentage agreements ranged from 57% to 100% and kappas ranged from .28 to 1.0. Meta-analytic combinations of reliability estimates obtained by independent evaluators returned estimates of κ = .49 (95% CI: .40-.58) for competency opinions and κ = .41 (95% CI: .29-.53) for sanity opinions. This wide range of reliability estimates underscores the extent to which different evaluation contexts tend to produce different reliability rates. Unfortunately, our study space analysis illustrates that available field reliability studies typically provide little information about contextual variables crucial to understanding their findings. Given these concerns, we offer suggestions for improving research on the field reliability of competency and sanity opinions, as well as suggestions for improving reliability rates themselves. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  2. Evaluation of the Transit Reliability Information Program

    DOT National Transportation Integrated Search

    1982-06-01

    This report presents an evaluation of the rail portion of the Transit Reliability Information Program (TRIP), which was designed to collect and analyze equipment reliability data on U.S. transit systems. This assessment was conducted at the end of it...

  3. Reliability analysis of laminated CMC components through shell subelement techniques

    NASA Technical Reports Server (NTRS)

    Starlinger, Alois; Duffy, Stephen F.; Gyekenyesi, John P.

    1992-01-01

    An updated version of the integrated design program Composite Ceramics Analysis and Reliability Evaluation of Structures (C/CARES) was developed for the reliability evaluation of ceramic matrix composites (CMC) laminated shell components. The algorithm is now split into two modules: a finite-element data interface program and a reliability evaluation algorithm. More flexibility is achieved, allowing for easy implementation with various finite-element programs. The interface program creates a neutral data base which is then read by the reliability module. This neutral data base concept allows easy data transfer between different computer systems. The new interface program from the finite-element code Matrix Automated Reduction and Coupling (MARC) also includes the option of using hybrid laminates (a combination of plies of different materials or different layups) and allows for variations in temperature fields throughout the component. In the current version of C/CARES, a subelement technique was implemented, enabling stress gradients within an element to be taken into account. The noninteractive reliability function is now evaluated at each Gaussian integration point instead of using averaging techniques. As a result of the increased number of stress evaluation points, considerable improvements in the accuracy of reliability analyses were realized.

  4. Dynamic MRI to quantify musculoskeletal motion: A systematic review of concurrent validity and reliability, and perspectives for evaluation of musculoskeletal disorders

    PubMed Central

    Lempereur, Mathieu; Lelievre, Mathieu; Burdin, Valérie; Ben Salem, Douraied; Brochard, Sylvain

    2017-01-01

    Purpose To report evidence for the concurrent validity and reliability of dynamic MRI techniques to evaluate in vivo joint and muscle mechanics, and to propose recommendations for their use in the assessment of normal and impaired musculoskeletal function. Materials and methods The search was conducted on articles published in Web of science, PubMed, Scopus, Academic search Premier, and Cochrane Library between 1990 and August 2017. Studies that reported the concurrent validity and/or reliability of dynamic MRI techniques for in vivo evaluation of joint or muscle mechanics were included after assessment by two independent reviewers. Selected articles were assessed using an adapted quality assessment tool and a data extraction process. Results for concurrent validity and reliability were categorized as poor, moderate, or excellent. Results Twenty articles fulfilled the inclusion criteria with a mean quality assessment score of 66% (±10.4%). Concurrent validity and/or reliability of eight dynamic MRI techniques were reported, with the knee being the most evaluated joint (seven studies). Moderate to excellent concurrent validity and reliability were reported for seven out of eight dynamic MRI techniques. Cine phase contrast and real-time MRI appeared to be the most valid and reliable techniques to evaluate joint motion, and spin tag for muscle motion. Conclusion Dynamic MRI techniques are promising for the in vivo evaluation of musculoskeletal mechanics; however results should be evaluated with caution since validity and reliability have not been determined for all joints and muscles, nor for many pathological conditions. PMID:29232401

  5. A XPS Study of the Passivity of Stainless Steels Influenced by Sulfate-Reducing Bacteria.

    NASA Astrophysics Data System (ADS)

    Chen, Guocun

    The influence of sulfate-reducing bacteria (SRB) on the passivity of type 304 and 317L stainless steels (SS) was investigated by x-ray photoelectron spectroscopy (XPS), microbiological and electrochemical techniques. Samples were exposed to SRB, and then the resultant surfaces were analyzed by XPS, and the corrosion resistance by potentiodynamic polarization in deaerated 0.1 M HCl. To further understand their passivity, the SRB-exposed samples were analyzed by XPS after potentiostatic polarization at a passive potential in the hydrochloric solution. The characterization was performed under two surface conditions: unrinsed and rinsed by deaerated alcohol and deionized water. Comparisons were made with control samples immersed in uninoculated medium. SRB caused a severe loss of the passivity of 304 SS through sulfide formation and possible additional activation to form hexavalent chromium. The sulfides included FeS, FeS_2, Cr_2S _3, NiS and possibly Fe_ {rm 1-x}S. The interaction took place nonuniformly, resulting in undercutting of the passive film and preferential hydration of inner surface layers. The bacterial activation of the Cr^{6+ }^ecies was magnified by subsequent potentiostatic polarization. In contrast, 317L SS exhibited a limited passivity. The sulfides were formed mainly in the outer layers. Although Cr^{6+}^ecies were observed after the exposure, they were dissolved upon polarization. Since 317L SS has a higher Mo content, its higher passivity was ascribed to Mo existing as molybdate on the surface and Mo^{5+} species in the biofilm. Consequently, the interaction of SRB with Mo was studied. It was observed that molybdate could be retained on the surfaces of Mo coupons by corrosion products. In the presence of SRB, however, a considerable portion of the molybdate interacted with intermediate sulfur -containing proteins, forming Mo(V)-S complexes and reducing bacterial growth and sulfate reduction. The limited insolubility of the Mo(V)-S complexes in 0.1 M HCl provided a certain protection so that the pitting potential of the SRB-exposed Mo coupons was not considerably decreased. The interaction of the sulfur-containing proteins with Mo also provided mechanistic information about the adhesion of biofilm to Mo-bearing steels. Additionally, the interactions of SRB with other alloying elements, Cr and Ni, were investigated.

  6. Reduction-Triggered Self-Assembly of Nanoscale Molybdenum Oxide Molecular Clusters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yin, Panchao; Wu, Bin; Li, Tao

    A 2.9 nm molybdenum oxide cluster {Mo 132} (Formula: [Mo VI 72Mo V 60O 372(CH 3COO) 30(H 2O) 72] 42-) can be obtained by reducing ammonium molybdate with hydrazine sulfate in weakly acidic CH 3COOH/CH 3COO- buffers. This reaction has been monitored by time-resolved UV-Vis, 1H-NMR, small angle X-ray/neutron scattering, and X-ray absorption near edge structure spectroscopy. The growth of {Mo 132} cluster shows a typical sigmoid curve, suggesting a multi-step assembly mechanism for this reaction. The reaction starts with a lag phase period when partial MoVI centers of molybdate precursors are reduced to form {MoV2(acetate)} structures under the coordinationmore » effect of the acetate groups. Once the concentration of {Mo V 2(acetate)} reaches a critical value, it triggers the assembly of Mo V and Mo VI species into {Mo 132} clusters. Parameters such as the type and amount of reducing agent, the pH, the type of cation, and the type of organic ligand in the reaction buffer, have been studied for the roles they play in the formation of the target clusters.Understanding the formation mechanism of giant molecular clusters is essential for rational design and synthesis of cluster-based nanomaterials with required morphologies and functionalities. Here, typical synthetic reactions of a 2.9 nm spherical molybdenum oxide cluster, {Mo 132} (formula: [Mo VI 72Mo V 60O 372(CH 3COO) 30(H 2O) 72] 42), with systematically varied reaction parameters have been fully explored to determine the morphologies and concentration of products, reduction of metal centers, and chemical environments of the organic ligands. The growth of these clusters shows a typical sigmoid curve, suggesting a general multistep self-assembly mechanism for the formation of giant molecular clusters. The reaction starts with a lag phase period when partial MoVI centers of molybdate precursors are reduced to form {Mo V 2(acetate)} structures under the coordination effect of the acetate groups. Once the concentration of {MoV2(acetate)} reaches a critical value, it triggers the co-assembly of Mo V and Mo VI species into the giant clusters.« less

  7. New Defective Brannerite-Type Vanadates. I. Synthesis and Study of Mn 1- x- yφ xNa yV 2-2 x-yMo 2 x+yO 6 Solid Solutions

    NASA Astrophysics Data System (ADS)

    Masłowska, Bogna; Ziółkowski, Jacek

    1994-05-01

    MnV 2O 6 of the brannerite-type structure (below 540°C) doped with MoO 3 and Na 2O forms isomorphous solid solutions MnNaφ = Mn 1- x-yφ xNa yV 2-2 x-yMo 2 x+ yO 6 (φ cation vacancy in the original Mn position), belonging to the pseudoternary MnV 2O 6-NaVMoO 6-MoO 3 system. Particular cases are MnNa = Mn 1- yNa y V 2- yMo yO 6 ( x = 0), Mnφ = Mn 1- xφ xV 2-2 xMo 2 xO 6 ( y = 0), and Naφ = Na 1- xφ xV 1- xMo 1+ xO 6 ( x + y = 1). MnV 2O 6 and NaVMoO 6 show miscibility in the entire composition range (MnNa). The opposite boundary of MnNaφ passes through the (100 x, 100 y) points (45, 0), (33, 30), and (30, 70). The phase diagram of the pseudobinary MnV 2O 6-NaVMoO 6 system (determined with DTA) shows (i) a narrow double-lens-type solidus-liquidus gap at high values of y , (ii) two peritectic meltings at lower y (yielding the high temperature β-MnNa and Mn 2V 2O 7), and (iii) little area of β-MnNa. Lattice parameters of MnNa (determined with X-ray diffraction) reveal small deviations from Vegard's law. As the ionic radii of both dopants (Na + and Mo 6+) are, respectively, larger than those of mother ions (Mn 2+ and V 5+), the unit cell increases in all directions with rising y along the MnNa series of solid solutions. However, due to the anisotropy of the structure, parameter c is strongly sensitive to Na/Mn substitution, b is ruled by Mo/V, and a is weakly influenced by Mo/V. Close analogy to the behavior of the previously studied MnV 2O 6-LiVMoO 6-MoO 6 system is discussed.

  8. Reduction-Triggered Self-Assembly of Nanoscale Molybdenum Oxide Molecular Clusters

    DOE PAGES

    Yin, Panchao; Wu, Bin; Li, Tao; ...

    2016-07-26

    A 2.9 nm molybdenum oxide cluster {Mo 132} (Formula: [Mo VI 72Mo V 60O 372(CH 3COO) 30(H 2O) 72] 42-) can be obtained by reducing ammonium molybdate with hydrazine sulfate in weakly acidic CH 3COOH/CH 3COO- buffers. This reaction has been monitored by time-resolved UV-Vis, 1H-NMR, small angle X-ray/neutron scattering, and X-ray absorption near edge structure spectroscopy. The growth of {Mo 132} cluster shows a typical sigmoid curve, suggesting a multi-step assembly mechanism for this reaction. The reaction starts with a lag phase period when partial MoVI centers of molybdate precursors are reduced to form {MoV2(acetate)} structures under the coordinationmore » effect of the acetate groups. Once the concentration of {Mo V 2(acetate)} reaches a critical value, it triggers the assembly of Mo V and Mo VI species into {Mo 132} clusters. Parameters such as the type and amount of reducing agent, the pH, the type of cation, and the type of organic ligand in the reaction buffer, have been studied for the roles they play in the formation of the target clusters.Understanding the formation mechanism of giant molecular clusters is essential for rational design and synthesis of cluster-based nanomaterials with required morphologies and functionalities. Here, typical synthetic reactions of a 2.9 nm spherical molybdenum oxide cluster, {Mo 132} (formula: [Mo VI 72Mo V 60O 372(CH 3COO) 30(H 2O) 72] 42), with systematically varied reaction parameters have been fully explored to determine the morphologies and concentration of products, reduction of metal centers, and chemical environments of the organic ligands. The growth of these clusters shows a typical sigmoid curve, suggesting a general multistep self-assembly mechanism for the formation of giant molecular clusters. The reaction starts with a lag phase period when partial MoVI centers of molybdate precursors are reduced to form {Mo V 2(acetate)} structures under the coordination effect of the acetate groups. Once the concentration of {MoV2(acetate)} reaches a critical value, it triggers the co-assembly of Mo V and Mo VI species into the giant clusters.« less

  9. Reliability and risk assessment of structures

    NASA Technical Reports Server (NTRS)

    Chamis, C. C.

    1991-01-01

    Development of reliability and risk assessment of structural components and structures is a major activity at Lewis Research Center. It consists of five program elements: (1) probabilistic loads; (2) probabilistic finite element analysis; (3) probabilistic material behavior; (4) assessment of reliability and risk; and (5) probabilistic structural performance evaluation. Recent progress includes: (1) the evaluation of the various uncertainties in terms of cumulative distribution functions for various structural response variables based on known or assumed uncertainties in primitive structural variables; (2) evaluation of the failure probability; (3) reliability and risk-cost assessment; and (4) an outline of an emerging approach for eventual certification of man-rated structures by computational methods. Collectively, the results demonstrate that the structural durability/reliability of man-rated structural components and structures can be effectively evaluated by using formal probabilistic methods.

  10. Soft error evaluation and vulnerability analysis in Xilinx Zynq-7010 system-on chip

    NASA Astrophysics Data System (ADS)

    Du, Xuecheng; He, Chaohui; Liu, Shuhuan; Zhang, Yao; Li, Yonghong; Xiong, Ceng; Tan, Pengkang

    2016-09-01

    Radiation-induced soft errors are an increasingly important threat to the reliability of modern electronic systems. In order to evaluate system-on chip's reliability and soft error, the fault tree analysis method was used in this work. The system fault tree was constructed based on Xilinx Zynq-7010 All Programmable SoC. Moreover, the soft error rates of different components in Zynq-7010 SoC were tested by americium-241 alpha radiation source. Furthermore, some parameters that used to evaluate the system's reliability and safety were calculated using Isograph Reliability Workbench 11.0, such as failure rate, unavailability and mean time to failure (MTTF). According to fault tree analysis for system-on chip, the critical blocks and system reliability were evaluated through the qualitative and quantitative analysis.

  11. Reliability and Availability Evaluation Program Manual.

    DTIC Science & Technology

    1982-11-01

    research and development. The manual’s purpose was to provide a practical method for making reliability measurements, measurements directly related to... Research , Development, Test and Evaluation. RMA Reliability, Maintainability and Availability. R&R Repair and Refurbishment, Repair and Replacement, etc...length. phenomena such as mechanical wear and A number of researchers in the reliability chemical deterioration. Maintenance should field 14-pages 402

  12. Assessing Assessment: Evaluating Outcomes and Reliabilities of Grammar, Math, and Writing Skill Measures in an Introductory Journalism Course

    ERIC Educational Resources Information Center

    Farwell, Tricia M.; Alligood, Leon; Fitzgerald, Sharon; Blake, Ken

    2016-01-01

    This article introduces an objective grammar and math assessment and evaluates the assessment's outcome and reliability when fielded among eighty-one students in media writing courses. In addition, the article proposes a rubric for grading straight news leads and compares the rubric's reliability with the reliability of rating straight news leads…

  13. Handwriting Movement Analyses for Monitoring Drug-Induced Motor Side Effects in Schizophrenia Patients Treated with Risperidone

    PubMed Central

    Caligiuri, Michael P.; Teulings, Hans-Leo; Dean, Charles E.; Niculescu, Alexander B.; Lohr, James

    2009-01-01

    Epidemiologic studies indicate that nearly 60% of schizophrenia (SZ) patients treated with conventional antipsychotic drugs develop extrapyramidal side effects (EPS) such as parkinsonism and tardive dyskinesia. Although the prevalence of EPS has decreased due to the newer antipsychotics, EPS continue to limit the effectiveness of these medicines. Ongoing monitoring of EPS is likely to improve treatment outcome or compliance and reduce the frequency of re-hospitalization. A quantitative analysis of handwriting kinematics was used to evaluate effects of antipsychotic medication type and dose in schizophrenia patients. Twenty-seven schizophrenia patients treated with risperidone, six schizophrenia patients who received no antipsychotic medication and 46 healthy comparison participants were enrolled. Participants performed a 20-minute handwriting task consisting of loops of various sizes and a sentence. Data were captured and analyzed using MovAlyzeR software. Results indicated that risperidone-treated participants exhibited significantly more dysfluent handwriting movements than either healthy or untreated SZ participants. Risperidone-treated participants exhibited lower movement velocities during production of simple loops compared to unmedicated patients. Handwriting dysfluency during sentence writing increased with dose. A 3-factor model consisting of kinematic variables derived from sentence writing accounted for 83% (r = .91) of the variability in medication dose. In contrast, we found no association between observer-based EPS severity ratings and medication dose. These findings support the importance of handwriting-based measures to monitor EPS in medicated schizophrenia patients. PMID:19692133

  14. Evaluating reliability of WSN with sleep/wake-up interfering nodes

    NASA Astrophysics Data System (ADS)

    Distefano, Salvatore

    2013-10-01

    A wireless sensor network (WSN) (singular and plural of acronyms are spelled the same) is a distributed system composed of autonomous sensor nodes wireless connected and randomly scattered into a geographical area to cooperatively monitor physical or environmental conditions. Adequate techniques and strategies are required to manage a WSN so that it works properly, observing specific quantities and metrics to evaluate the WSN operational conditions. Among them, one of the most important is the reliability. Considering a WSN as a system composed of sensor nodes the system reliability approach can be applied, thus expressing the WSN reliability in terms of its nodes' reliability. More specifically, since often standby power management policies are applied at node level and interferences among nodes may arise, a WSN can be considered as a dynamic system. In this article we therefore consider the WSN reliability evaluation problem from the dynamic system reliability perspective. Static-structural interactions are specified by the WSN topology. Sleep/wake-up standby policies and interferences due to wireless communications can be instead considered as dynamic aspects. Thus, in order to represent and to evaluate the WSN reliability, we use dynamic reliability block diagrams and Petri nets. The proposed technique allows to overcome the limits of Markov models when considering non-linear discharge processes, since they cannot adequately represent the aging processes. In order to demonstrate the effectiveness of the technique, we investigate some specific WSN network topologies, providing guidelines for their representation and evaluation.

  15. A Standardized Rubric for Evaluating Webquest Design: Reliability Analysis of ZUNAL Webquest Design Rubric

    ERIC Educational Resources Information Center

    Unal, Zafer; Bodur, Yasar; Unal, Aslihan

    2012-01-01

    Current literature provides many examples of rubrics that are used to evaluate the quality of web-quest designs. However, reliability of these rubrics has not yet been researched. This is the first study to fully characterize and assess the reliability of a webquest evaluation rubric. The ZUNAL rubric was created to utilize the strengths of the…

  16. The Application of a Residual Risk Evaluation Technique Used for Expendable Launch Vehicles

    NASA Technical Reports Server (NTRS)

    Latimer, John A.

    2009-01-01

    This presentation provides a Residual Risk Evaluation Technique (RRET) developed by Kennedy Space Center (KSC) Safety and Mission Assurance (S&MA) Launch Services Division. This technique is one of many procedures used by S&MA at KSC to evaluate residual risks for each Expendable Launch Vehicle (ELV) mission. RRET is a straight forward technique that incorporates the proven methodology of risk management, fault tree analysis, and reliability prediction. RRET derives a system reliability impact indicator from the system baseline reliability and the system residual risk reliability values. The system reliability impact indicator provides a quantitative measure of the reduction in the system baseline reliability due to the identified residual risks associated with the designated ELV mission. An example is discussed to provide insight into the application of RRET.

  17. Dynamic decision-making for reliability and maintenance analysis of manufacturing systems based on failure effects

    NASA Astrophysics Data System (ADS)

    Zhang, Ding; Zhang, Yingjie

    2017-09-01

    A framework for reliability and maintenance analysis of job shop manufacturing systems is proposed in this paper. An efficient preventive maintenance (PM) policy in terms of failure effects analysis (FEA) is proposed. Subsequently, reliability evaluation and component importance measure based on FEA are performed under the PM policy. A job shop manufacturing system is applied to validate the reliability evaluation and dynamic maintenance policy. Obtained results are compared with existed methods and the effectiveness is validated. Some vague understandings for issues such as network modelling, vulnerabilities identification, the evaluation criteria of repairable systems, as well as PM policy during manufacturing system reliability analysis are elaborated. This framework can help for reliability optimisation and rational maintenance resources allocation of job shop manufacturing systems.

  18. Reliability in perceptual analysis of voice quality.

    PubMed

    Bele, Irene Velsvik

    2005-12-01

    This study focuses on speaking voice quality in male teachers (n = 35) and male actors (n = 36), who represent untrained and trained voice users, because we wanted to investigate normal and supranormal voices. In this study, both substantial and methodologic aspects were considered. It includes a method for perceptual voice evaluation, and a basic issue was rater reliability. A listening group of 10 listeners, 7 experienced speech-language therapists, and 3 speech-language therapist students evaluated the voices by 15 vocal characteristics using VA scales. Two sets of voice signals were investigated: text reading (2 loudness levels) and sustained vowel (3 levels). The results indicated a high interrater reliability for most perceptual characteristics. Connected speech was evaluated more reliably, especially at the normal level, but both types of voice signals were evaluated reliably, although the reliability for connected speech was somewhat higher than for vowels. Experienced listeners tended to be more consistent in their ratings than did the student raters. Some vocal characteristics achieved acceptable reliability even with a smaller panel of listeners. The perceptual characteristics grouped in 4 factors reflected perceptual dimensions.

  19. Reliability studies of Integrated Modular Engine system designs

    NASA Technical Reports Server (NTRS)

    Hardy, Terry L.; Rapp, Douglas C.

    1993-01-01

    A study was performed to evaluate the reliability of Integrated Modular Engine (IME) concepts. Comparisons were made between networked IME systems and non-networked discrete systems using expander cycle configurations. Both redundant and non-redundant systems were analyzed. Binomial approximation and Markov analysis techniques were employed to evaluate total system reliability. In addition, Failure Modes and Effects Analyses (FMEA), Preliminary Hazard Analyses (PHA), and Fault Tree Analysis (FTA) were performed to allow detailed evaluation of the IME concept. A discussion of these system reliability concepts is also presented.

  20. Reliability studies of integrated modular engine system designs

    NASA Technical Reports Server (NTRS)

    Hardy, Terry L.; Rapp, Douglas C.

    1993-01-01

    A study was performed to evaluate the reliability of Integrated Modular Engine (IME) concepts. Comparisons were made between networked IME systems and non-networked discrete systems using expander cycle configurations. Both redundant and non-redundant systems were analyzed. Binomial approximation and Markov analysis techniques were employed to evaluate total system reliability. In addition, Failure Modes and Effects Analyses (FMEA), Preliminary Hazard Analyses (PHA), and Fault Tree Analysis (FTA) were performed to allow detailed evaluation of the IME concept. A discussion of these system reliability concepts is also presented.

  1. A new criterion needed to evaluate reliability of digital protective relays

    NASA Astrophysics Data System (ADS)

    Gurevich, Vladimir

    2012-11-01

    There is a wide range of criteria and features for evaluating reliability in engineering; but as many as there are, only one of them has been chosen to evaluate reliability of Digital Protective Relays (DPR) in the technical documentation: Mean (operating) Time Between Failures (MTBF), which has gained universal currency and has been specified in technical manuals, information sheets, tender documentation as the key indicator of DPR reliability. But is the choice of this criterion indeed wise? The answer to this question is being sought by the author of this article.

  2. Reliability analysis of laminated CMC components through shell subelement techniques

    NASA Technical Reports Server (NTRS)

    Starlinger, A.; Duffy, S. F.; Gyekenyesi, J. P.

    1992-01-01

    An updated version of the integrated design program C/CARES (composite ceramic analysis and reliability evaluation of structures) was developed for the reliability evaluation of CMC laminated shell components. The algorithm is now split in two modules: a finite-element data interface program and a reliability evaluation algorithm. More flexibility is achieved, allowing for easy implementation with various finite-element programs. The new interface program from the finite-element code MARC also includes the option of using hybrid laminates and allows for variations in temperature fields throughout the component.

  3. Reliability studies of integrated modular engine system designs

    NASA Astrophysics Data System (ADS)

    Hardy, Terry L.; Rapp, Douglas C.

    1993-06-01

    A study was performed to evaluate the reliability of Integrated Modular Engine (IME) concepts. Comparisons were made between networked IME systems and non-networked discrete systems using expander cycle configurations. Both redundant and non-redundant systems were analyzed. Binomial approximation and Markov analysis techniques were employed to evaluate total system reliability. In addition, Failure Modes and Effects Analyses (FMEA), Preliminary Hazard Analyses (PHA), and Fault Tree Analysis (FTA) were performed to allow detailed evaluation of the IME concept. A discussion of these system reliability concepts is also presented.

  4. Reliability studies of Integrated Modular Engine system designs

    NASA Astrophysics Data System (ADS)

    Hardy, Terry L.; Rapp, Douglas C.

    1993-06-01

    A study was performed to evaluate the reliability of Integrated Modular Engine (IME) concepts. Comparisons were made between networked IME systems and non-networked discrete systems using expander cycle configurations. Both redundant and non-redundant systems were analyzed. Binomial approximation and Markov analysis techniques were employed to evaluate total system reliability. In addition, Failure Modes and Effects Analyses (FMEA), Preliminary Hazard Analyses (PHA), and Fault Tree Analysis (FTA) were performed to allow detailed evaluation of the IME concept. A discussion of these system reliability concepts is also presented.

  5. Reviewing Reliability and Validity of Information for University Educational Evaluation

    NASA Astrophysics Data System (ADS)

    Otsuka, Yusaku

    To better utilize evaluations in higher education, it is necessary to share the methods of reviewing reliability and validity of examination scores and grades, and to accumulate and share data for confirming results. Before the GPA system is first introduced into a university or college, the reliability of examination scores and grades, especially for essay examinations, must be assured. Validity is a complicated concept, so should be assured in various ways, including using professional audits, theoretical models, and statistical data analysis. Because individual students and teachers are continually improving, using evaluations to appraise their progress is not always compatible with using evaluations in appraising the implementation of accountability in various departments or the university overall. To better utilize evaluations and improve higher education, evaluations should be integrated into the current system by sharing the vision of an academic learning community and promoting interaction between students and teachers based on sufficiently reliable and validated evaluation tools.

  6. Evaluating the Inter-Respondent (Consumer vs. Staff) Reliability and Construct Validity (SIS vs. Vineland) of the Supports Intensity Scale on a Dutch Sample

    ERIC Educational Resources Information Center

    Claes, C.; Van Hove, G.; van Loon, J.; Vandevelde, S.; Schalock, R. L.

    2009-01-01

    Background: Despite various reliability studies on the Supports Intensity Scale (SIS), to date there has not been an evaluation of the reliability of client vs. staff judgments. Such determination is important, given the increasing consumer-driven approach to services. Additionally, there has not been an evaluation of the instrument's construct…

  7. Intra- and inter-observer reliability of ten major histological scoring systems used for the evaluation of in vivo cartilage repair.

    PubMed

    Bonasia, Davide Edoardo; Marmotti, Antongiulio; Massa, Alessandro Domenico Felice; Ferro, Andrea; Blonna, Davide; Castoldi, Filippo; Rossi, Roberto

    2015-09-01

    In the last two decades, many surgical techniques have been described for articular cartilage repair. Reliable histological scoring systems are fundamental tools to evaluate new procedures. Several histological scoring systems have been described, and these can be divided in elementary and comprehensive scores, according to the number of sub-items. The aim of this study was to test the inter- and intra-observer reliability of ten main scores used for the histological evaluation of in vivo cartilage repair. The authors tested the starting hypothesis that elementary scores would show superior intra- and inter-observer reliability compared with comprehensive scores. Fifty histological sections obtained from the trochlea of New Zealand Rabbit and stained with Safranin-O fast green were used. The histological sections were analysed by 4 observers: 2 experienced in cartilage histology and 2 inexperienced. Histological evaluations were performed at time 1 and time 2, separated by a 30-day interval. The following scores were used: Mankin, O'Driscoll, Pineda, Wakitani, Fortier, Selleres, ICRS, ICRSII, Oswestry (OsScore) and modified O'Driscoll. Intra- and inter-observer reliability were evaluated for each score. In addition, the pavement-ceiling effect and the Bland-Altman Coefficient of Repeatability were then evaluated for each sub-item of every score. Intra-observer reliability was high for all observers in every score, even though the reliability was significantly lower for non-expert observers compared with expert counterparts. In terms of Coefficient of Repeatability, some scores performed better (O'Driscoll, Modified O'Driscoll and ICRSII) than others (Fortier, Seller). Inter-observer reliability was high for all observers in every score, but significantly lower for non-expert compared with expert observers. In expert hands, all the scores showed high intra- and inter-observer reliability, independently of the complexity. Although every score has advantages and disadvantages, ICRSII, O'Driscoll and Modified O'Driscoll scores should be preferred for the evaluation of in vivo cartilage repair in animal models.

  8. Scale Reliability Evaluation with Heterogeneous Populations

    ERIC Educational Resources Information Center

    Raykov, Tenko; Marcoulides, George A.

    2015-01-01

    A latent variable modeling approach for scale reliability evaluation in heterogeneous populations is discussed. The method can be used for point and interval estimation of reliability of multicomponent measuring instruments in populations representing mixtures of an unknown number of latent classes or subpopulations. The procedure is helpful also…

  9. A reliability evaluation methodology for memory chips for space applications when sample size is small

    NASA Technical Reports Server (NTRS)

    Chen, Y.; Nguyen, D.; Guertin, S.; Berstein, J.; White, M.; Menke, R.; Kayali, S.

    2003-01-01

    This paper presents a reliability evaluation methodology to obtain the statistical reliability information of memory chips for space applications when the test sample size needs to be kept small because of the high cost of the radiation hardness memories.

  10. Reliability testing of two classification systems for osteoarthritis and post-traumatic arthritis of the elbow.

    PubMed

    Amini, Michael H; Sykes, Joshua B; Olson, Stephen T; Smith, Richard A; Mauck, Benjamin M; Azar, Frederick M; Throckmorton, Thomas W

    2015-03-01

    The severity of elbow arthritis is one of many factors that surgeons must evaluate when considering treatment options for a given patient. Elbow surgeons have historically used the Broberg and Morrey (BM) and Hastings and Rettig (HR) classification systems to radiographically stage the severity of post-traumatic arthritis (PTA) and primary osteoarthritis (OA). We proposed to compare the intraobserver and interobserver reliability between systems for patients with either PTA or OA. The radiographs of 45 patients were evaluated at least 2 weeks apart by 6 evaluators of different levels of training. Intraobserver and interobserver reliability were calculated by Spearman correlation coefficients with 95% confidence intervals. Agreement was considered almost perfect for coefficients >0.80 and substantial for coefficients of 0.61 to 0.80. In patients with both PTA and OA, intraobserver reliability and interobserver reliability were substantial, with no difference between classification systems. There were no significant differences in intraobserver or interobserver reliability between attending physicians and trainees for either classification system (all P > .10). The presence of fracture implants did not affect reliability in the BM system but did substantially worsen reliability in the HR system (intraobserver P = .04 and interobserver P = .001). The BM and HR classifications both showed substantial intraobserver and interobserver reliability for PTA and OA. Training level differences did not affect reliability for either system. Both trainees and fellowship-trained surgeons may easily and reliably apply each classification system to the evaluation of primary elbow OA and PTA, although the HR system was less reliable in the presence of fracture implants. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  11. Development of a Peer Teaching-Assessment Program and a Peer Observation and Evaluation Tool

    PubMed Central

    Trujillo, Jennifer M.; Barr, Judith; Gonyeau, Michael; Van Amburgh, Jenny A.; Matthews, S. James; Qualters, Donna

    2008-01-01

    Objectives To develop a formalized, comprehensive, peer-driven teaching assessment program and a valid and reliable assessment tool. Methods A volunteer taskforce was formed and a peer-assessment program was developed using a multistep, sequential approach and the Peer Observation and Evaluation Tool (POET). A pilot study was conducted to evaluate the efficiency and practicality of the process and to establish interrater reliability of the tool. Intra-class correlation coefficients (ICC) were calculated. Results ICCs for 8 separate lectures evaluated by 2-3 observers ranged from 0.66 to 0.97, indicating good interrater reliability of the tool. Conclusion Our peer assessment program for large classroom teaching, which includes a valid and reliable evaluation tool, is comprehensive, feasible, and can be adopted by other schools of pharmacy. PMID:19325963

  12. Modeling of unit operating considerations in generating-capacity reliability evaluation. Volume 1. Mathematical models, computing methods, and results. Final report. [GENESIS, OPCON and OPPLAN

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patton, A.D.; Ayoub, A.K.; Singh, C.

    1982-07-01

    Existing methods for generating capacity reliability evaluation do not explicitly recognize a number of operating considerations which may have important effects in system reliability performance. Thus, current methods may yield estimates of system reliability which differ appreciably from actual observed reliability. Further, current methods offer no means of accurately studying or evaluating alternatives which may differ in one or more operating considerations. Operating considerations which are considered to be important in generating capacity reliability evaluation include: unit duty cycles as influenced by load cycle shape, reliability performance of other units, unit commitment policy, and operating reserve policy; unit start-up failuresmore » distinct from unit running failures; unit start-up times; and unit outage postponability and the management of postponable outages. A detailed Monte Carlo simulation computer model called GENESIS and two analytical models called OPCON and OPPLAN have been developed which are capable of incorporating the effects of many operating considerations including those noted above. These computer models have been used to study a variety of actual and synthetic systems and are available from EPRI. The new models are shown to produce system reliability indices which differ appreciably from index values computed using traditional models which do not recognize operating considerations.« less

  13. Interexaminer reliability in physical examination of patients with low back pain.

    PubMed

    Strender, L E; Sjöblom, A; Sundell, K; Ludwig, R; Taube, A

    1997-04-01

    Seventy-one patients with low back pain were examined by two physiotherapists (50 patients) and two physicians (21 patients). The two physiotherapists had worked together for many years, but the two physicians had not. The interexaminer reliability of the clinical tests included in the physical examination was evaluated. To evaluate the interexaminer reliability of clinical tests used in the physical examination of patients with low back pain under ideal circumstances, which was the case for the physiotherapists. Numerous clinical tests are used in the evaluation of patients with low back pain. To reach the correct diagnosis, only tests with an acceptable validity and reliability should be used. Previous studies have mainly shown low reliability. It is important that clinical tests not be rejected because of low reliability caused by differences between examiners in performance of the examination and in their definition of normal results. Two examiners, either two physiotherapists or two physicians, independently examined patients with low back pain. In approximately half of the clinical tests studied, an acceptable reliability was demonstrated. On the basis of the physiotherapists series, the reliability was acceptable for a number of clinical tests that are used in the evaluation of patients with low back pain. The results suggest that clinical tests should be standardized to a much higher degree than they are today.

  14. Writing Evaluation: Rater and Task Effects on the Reliability of Writing Scores for Children in Grades 3 and 4

    PubMed Central

    Kim, Grace Young-Suk; Schatschneider, Christopher; Wanzek, Jeanne; Gatlin, Brandy; Al Otaiba, Stephanie

    2017-01-01

    We examined how raters and tasks influence measurement error in writing evaluation and how many raters and tasks are needed to reach a desirable level of .90 and .80 reliabilities for children in Grades 3 and 4. A total of 211 children (102 boys) were administered three tasks in narrative and expository genres, respectively, and their written compositions were evaluated in widely used evaluation methods for developing writers: holistic scoring, productivity, and curriculum-based writing scores. Results showed that 54% and 52% of variance in narrative and expository compositions were attributable to true individual differences in writing. Students’ scores varied largely by tasks (30.44% and 28.61% of variance), but not by raters. To reach the reliability of .90, multiple tasks and raters were needed, and for the reliability of .80, a single rater and multiple tasks were needed. These findings offer important implications about reliably evaluating children’s writing skills, given that writing is typically evaluated by a single task and a single rater in classrooms and even in state accountability systems. PMID:29075050

  15. Reproducibility of sonographic measurement of thickness and echogenicity of the plantar fascia.

    PubMed

    Cheng, Ju-Wen; Tsai, Wen-Chung; Yu, Tung-Yang; Huang, Kuo-Yao

    2012-01-01

    To evaluate the intra- and interrater reliability of ultrasonographic measurements of the thickness and echogenicity of the plantar fascia. Eleven patients (20 feet), who complained of inferior heel pain, and 26 volunteers (52 feet) were enrolled. Two sonographers independently imaged the plantar fascia in both longitudinal and transverse planes. Volunteers were assessed twice to evaluate intrarater reliability. Quantitative evaluation of the echogenicity of the plantar fascia was performed by measuring the mean gray level of the region of interest using Digital Imaging and Communications in Medicine viewer software. Sonographic evaluation of the thickness of the plantar fascia showed high reliability. Sonographic evaluations of the presence or absence of hypoechoic change in the plantar fascia showed surprisingly low agreement. The reliability of gray-scale evaluations appears to be much better than subjective judgments in the evaluation of echogenicity. Transverse scanning did not show any advantage in sonographic evaluation of the plantar fascia. The reliability of sonographic examination of the thickness of the plantar fascia is high. Mean gray-level analysis of quantitative sonography can be used for the evaluation of echogenicity, which could reduce discrepancies in the interpretation of echogenicity by different sonographers. Longitudinal instead of transverse scanning is recommended for imaging the plantar fascia. Copyright © 2011 Wiley Periodicals, Inc.

  16. Software reliability through fault-avoidance and fault-tolerance

    NASA Technical Reports Server (NTRS)

    Vouk, Mladen A.; Mcallister, David F.

    1992-01-01

    Accomplishments in the following research areas are summarized: structure based testing, reliability growth, and design testability with risk evaluation; reliability growth models and software risk management; and evaluation of consensus voting, consensus recovery block, and acceptance voting. Four papers generated during the reporting period are included as appendices.

  17. Behavioral Scale Reliability and Measurement Invariance Evaluation Using Latent Variable Modeling

    ERIC Educational Resources Information Center

    Raykov, Tenko

    2004-01-01

    A latent variable modeling approach to reliability and measurement invariance evaluation for multiple-component measuring instruments is outlined. An initial discussion deals with the limitations of coefficient alpha, a frequently used index of composite reliability. A widely and readily applicable structural modeling framework is next described…

  18. Automation of reliability evaluation procedures through CARE - The computer-aided reliability estimation program.

    NASA Technical Reports Server (NTRS)

    Mathur, F. P.

    1972-01-01

    Description of an on-line interactive computer program called CARE (Computer-Aided Reliability Estimation) which can model self-repair and fault-tolerant organizations and perform certain other functions. Essentially CARE consists of a repository of mathematical equations defining the various basic redundancy schemes. These equations, under program control, are then interrelated to generate the desired mathematical model to fit the architecture of the system under evaluation. The mathematical model is then supplied with ground instances of its variables and is then evaluated to generate values for the reliability-theoretic functions applied to the model.

  19. Reliability evaluation of microgrid considering incentive-based demand response

    NASA Astrophysics Data System (ADS)

    Huang, Ting-Cheng; Zhang, Yong-Jun

    2017-07-01

    Incentive-based demand response (IBDR) can guide customers to adjust their behaviour of electricity and curtail load actively. Meanwhile, distributed generation (DG) and energy storage system (ESS) can provide time for the implementation of IBDR. The paper focus on the reliability evaluation of microgrid considering IBDR. Firstly, the mechanism of IBDR and its impact on power supply reliability are analysed. Secondly, the IBDR dispatch model considering customer’s comprehensive assessment and the customer response model are developed. Thirdly, the reliability evaluation method considering IBDR based on Monte Carlo simulation is proposed. Finally, the validity of the above models and method is studied through numerical tests on modified RBTS Bus6 test system. Simulation results demonstrated that IBDR can improve the reliability of microgrid.

  20. Probability techniques for reliability analysis of composite materials

    NASA Technical Reports Server (NTRS)

    Wetherhold, Robert C.; Ucci, Anthony M.

    1994-01-01

    Traditional design approaches for composite materials have employed deterministic criteria for failure analysis. New approaches are required to predict the reliability of composite structures since strengths and stresses may be random variables. This report will examine and compare methods used to evaluate the reliability of composite laminae. The two types of methods that will be evaluated are fast probability integration (FPI) methods and Monte Carlo methods. In these methods, reliability is formulated as the probability that an explicit function of random variables is less than a given constant. Using failure criteria developed for composite materials, a function of design variables can be generated which defines a 'failure surface' in probability space. A number of methods are available to evaluate the integration over the probability space bounded by this surface; this integration delivers the required reliability. The methods which will be evaluated are: the first order, second moment FPI methods; second order, second moment FPI methods; the simple Monte Carlo; and an advanced Monte Carlo technique which utilizes importance sampling. The methods are compared for accuracy, efficiency, and for the conservativism of the reliability estimation. The methodology involved in determining the sensitivity of the reliability estimate to the design variables (strength distributions) and importance factors is also presented.

  1. Reliability and Validity of the TIMPSI for Infants With Spinal Muscular Atrophy Type I

    PubMed Central

    Krosschell, Kristin J.; Maczulski, Jo Anne; Scott, Charles; King, Wendy; Hartman, Jill T.; Case, Laura E.; Viazzo-Trussell, Donata; Wood, Janine; Roman, Carolyn A.; Hecker, Eva; Meffert, Marianne; Léveillé, Maude; Kienitz, Krista; Swoboda, Kathryn J.

    2014-01-01

    Purpose This study examined the reliability and validity of the Test of Infant Motor Performance Screening Items (TIMPSI) in infants with type I spinal muscular atrophy (SMA). Methods After training, 12 evaluators scored 4 videos of infants with type I SMA to assess interrater reliability. Intrarater and test-retest reliability was further assessed for 9 evaluators during a SMA type I clinical trial, with 9 evaluators testing a total of 38 infants twice. Relatedness of the TIMPSI score to ability to reach and ventilatory support was also examined. Results Excellent interrater video score reliability was noted (intraclass correlation coefficient, 0.97–0.98). Intrarater reliability was excellent (intraclass correlation coefficient, 0.91–0.98) and test-retest reliability ranged from r = 0.82 to r = 0.95. The TIMPSI score was related to the ability to reach (P ≤ .05). Conclusion The TIMPSI can reliably be used to assess motor function in infants with type I SMA. In addition, the TIMPSI scores are related to the ability to reach, an important functional skill in children with type I SMA. PMID:23542189

  2. Evaluation Applied to Reliability Analysis of Reconfigurable, Highly Reliable, Fault-Tolerant, Computing Systems for Avionics

    NASA Technical Reports Server (NTRS)

    Migneault, G. E.

    1979-01-01

    Emulation techniques are proposed as a solution to a difficulty arising in the analysis of the reliability of highly reliable computer systems for future commercial aircraft. The difficulty, viz., the lack of credible precision in reliability estimates obtained by analytical modeling techniques are established. The difficulty is shown to be an unavoidable consequence of: (1) a high reliability requirement so demanding as to make system evaluation by use testing infeasible, (2) a complex system design technique, fault tolerance, (3) system reliability dominated by errors due to flaws in the system definition, and (4) elaborate analytical modeling techniques whose precision outputs are quite sensitive to errors of approximation in their input data. The technique of emulation is described, indicating how its input is a simple description of the logical structure of a system and its output is the consequent behavior. The use of emulation techniques is discussed for pseudo-testing systems to evaluate bounds on the parameter values needed for the analytical techniques.

  3. How Reliable Are Students' Evaluations of Teaching Quality? A Variance Components Approach

    ERIC Educational Resources Information Center

    Feistauer, Daniela; Richter, Tobias

    2017-01-01

    The inter-rater reliability of university students' evaluations of teaching quality was examined with cross-classified multilevel models. Students (N = 480) evaluated lectures and seminars over three years with a standardised evaluation questionnaire, yielding 4224 data points. The total variance of these student evaluations was separated into the…

  4. Validity and reliability assessment of a peer evaluation method in team-based learning classes.

    PubMed

    Yoon, Hyun Bae; Park, Wan Beom; Myung, Sun-Jung; Moon, Sang Hui; Park, Jun-Bean

    2018-03-01

    Team-based learning (TBL) is increasingly employed in medical education because of its potential to promote active group learning. In TBL, learners are usually asked to assess the contributions of peers within their group to ensure accountability. The purpose of this study is to assess the validity and reliability of a peer evaluation instrument that was used in TBL classes in a single medical school. A total of 141 students were divided into 18 groups in 11 TBL classes. The students were asked to evaluate their peers in the group based on evaluation criteria that were provided to them. We analyzed the comments that were written for the highest and lowest achievers to assess the validity of the peer evaluation instrument. The reliability of the instrument was assessed by examining the agreement among peer ratings within each group of students via intraclass correlation coefficient (ICC) analysis. Most of the students provided reasonable and understandable comments for the high and low achievers within their group, and most of those comments were compatible with the evaluation criteria. The average ICC of each group ranged from 0.390 to 0.863, and the overall average was 0.659. There was no significant difference in inter-rater reliability according to the number of members in the group or the timing of the evaluation within the course. The peer evaluation instrument that was used in the TBL classes was valid and reliable. Providing evaluation criteria and rules seemed to improve the validity and reliability of the instrument.

  5. A Systems Engineering Approach to Aircraft Kinetic Kill Countermeasures Technology: Development of an Active Aircraft Defense System for the C/KC-135 Aircraft. Volume 1

    DTIC Science & Technology

    1995-12-01

    comparison among all candidate systems , the reliability of each aircraft defense would evenly affect the evaluation of each system , and would have the...more reliable data. Obviously the more reliable and accurate the data evaluated though the hierarchy chart, the better the results. 29 IV. System ...1.3.5 System Evaluation ................................................................ 6 1.3.6 Decision M aking

  6. Evaluation of General Classes of Reliability Estimators Often Used in Statistical Analyses of Quasi-Experimental Designs

    NASA Astrophysics Data System (ADS)

    Saini, K. K.; Sehgal, R. K.; Sethi, B. L.

    2008-10-01

    In this paper major reliability estimators are analyzed and there comparatively result are discussed. There strengths and weaknesses are evaluated in this case study. Each of the reliability estimators has certain advantages and disadvantages. Inter-rater reliability is one of the best ways to estimate reliability when your measure is an observation. However, it requires multiple raters or observers. As an alternative, you could look at the correlation of ratings of the same single observer repeated on two different occasions. Each of the reliability estimators will give a different value for reliability. In general, the test-retest and inter-rater reliability estimates will be lower in value than the parallel forms and internal consistency ones because they involve measuring at different times or with different raters. Since reliability estimates are often used in statistical analyses of quasi-experimental designs.

  7. Nutrition Environment Measures Survey in stores (NEMS-S): development and evaluation.

    PubMed

    Glanz, Karen; Sallis, James F; Saelens, Brian E; Frank, Lawrence D

    2007-04-01

    Eating, or nutrition, environments are believed to contribute to obesity and chronic diseases. There is a need for valid, reliable measures of nutrition environments. This article reports on the development and evaluation of measures of nutrition environments in retail food stores. The Nutrition Environment Measures Study developed observational measures of the nutrition environment within retail food stores (NEMS-S) to assess availability of healthy options, price, and quality. After pretesting, measures were completed by independent raters to evaluate inter-rater reliability and across two occasions to assess test-retest reliability in grocery and convenience stores in four neighborhoods differing on income and community design in the Atlanta metropolitan area. Data were collected and analyzed in 2004 and 2005. Ten food categories (e.g., fruits) or indicator food items (e.g., ground beef) were evaluated in 85 stores. Inter-rater reliability and test-retest reliability of availability were high: inter-rater reliability kappas were 0.84 to 1.00, and test-retest reliabilities were .73 to 1.00. Inter-rater reliability for quality across fresh produce was moderate (kappas, 0.44 to 1.00). Healthier options were higher priced for hot dogs, lean ground beef, and baked chips. More healthful options were available in grocery than convenience stores and in stores in higher income neighborhoods. The NEMS-S tool was found to have a high degree of inter-rater and test-retest reliability, and to reveal significant differences across store types and neighborhoods of high and low socioeconomic status. These observational measures of nutrition environments can be applied in multilevel studies of community nutrition, and can inform new approaches to conducting and evaluating nutrition interventions.

  8. Intertester and intratester reliability of movement control tests on the hip for patients with hip osteoarthritis.

    PubMed

    Lenzlinger-Asprion, Rahel; Keller, Niculina; Meichtry, André; Luomajoki, Hannu

    2017-01-31

    Hip joint complaints are a problem associated with increasing age and impair the mobility of a large section of the elderly population. Reliable and valid tests are necessary for a thorough investigation of a joint. A fundamental function of the hip joint is movement control and a test of this function forms a part of the standard examination. Until now there have been few scientific studies which specifically investigate the reliability of measurement tests of movement control of the hip joint. The aim of this study was to examine the intratester and intertester reliability of the movement control tests of the hip joint which are in use in current clinical practice. Sixteen participants with hip joint complaints and 14 without hip joint impairment were recruited. All participants performed five active movement control tests for the hip joint and were video filmed whilst performing these tests. These films formed the basis for the evaluation and were assessed by two independent physiotherapists. For the intertester and intratester reliability calculations specially set weighted kappa values and the calculated percentages were used. The intertester reliability of the five examined movement control tests of the hip joint showed good to almost perfect values (weighted kappa (wk) = 0.56-0.87). The intratester reliability of the more experienced evaluator A was better in regards to the less experienced evaluator B (average wk = 0.62 vs 0.38). The visual evaluation of movement control tests of the hip joint is especially reliable when carried out by an experienced evaluator. 4 out of 5 tests also showed good results for intertester reliability and support their use in clinical practice.

  9. Models for evaluating the performability of degradable computing systems

    NASA Technical Reports Server (NTRS)

    Wu, L. T.

    1982-01-01

    Recent advances in multiprocessor technology established the need for unified methods to evaluate computing systems performance and reliability. In response to this modeling need, a general modeling framework that permits the modeling, analysis and evaluation of degradable computing systems is considered. Within this framework, several user oriented performance variables are identified and shown to be proper generalizations of the traditional notions of system performance and reliability. Furthermore, a time varying version of the model is developed to generalize the traditional fault tree reliability evaluation methods of phased missions.

  10. Measuring stakeholder participation in evaluation: an empirical validation of the Participatory Evaluation Measurement Instrument (PEMI).

    PubMed

    Daigneault, Pierre-Marc; Jacob, Steve; Tremblay, Joël

    2012-08-01

    Stakeholder participation is an important trend in the field of program evaluation. Although a few measurement instruments have been proposed, they either have not been empirically validated or do not cover the full content of the concept. This study consists of a first empirical validation of a measurement instrument that fully covers the content of participation, namely the Participatory Evaluation Measurement Instrument (PEMI). It specifically examines (1) the intercoder reliability of scores derived by two research assistants on published evaluation cases; (2) the convergence between the scores of coders and those of key respondents (i.e., authors); and (3) the convergence between the authors' scores on the PEMI and the Evaluation Involvement Scale (EIS). A purposive sample of 40 cases drawn from the evaluation literature was used to assess reliability. One author per case in this sample was then invited to participate in a survey; 25 fully usable questionnaires were received. Stakeholder participation was measured on nominal and ordinal scales. Cohen's κ, the intraclass correlation coefficient, and Spearman's ρ were used to assess reliability and convergence. Reliability results ranged from fair to excellent. Convergence between coders' and authors' scores ranged from poor to good. Scores derived from the PEMI and the EIS were moderately associated. Evidence from this study is strong in the case of intercoder reliability and ranges from weak to strong in the case of convergent validation. Globally, this suggests that the PEMI can produce scores that are both reliable and valid.

  11. Exploring the validity and reliability of a questionnaire for evaluating veterinary clinical teachers' supervisory skills during clinical rotations.

    PubMed

    Boerboom, T B B; Dolmans, D H J M; Jaarsma, A D C; Muijtjens, A M M; Van Beukelen, P; Scherpbier, A J J A

    2011-01-01

    Feedback to aid teachers in improving their teaching requires validated evaluation instruments. When implementing an evaluation instrument in a different context, it is important to collect validity evidence from multiple sources. We examined the validity and reliability of the Maastricht Clinical Teaching Questionnaire (MCTQ) as an instrument to evaluate individual clinical teachers during short clinical rotations in veterinary education. We examined four sources of validity evidence: (1) Content was examined based on theory of effective learning. (2) Response process was explored in a pilot study. (3) Internal structure was assessed by confirmatory factor analysis using 1086 student evaluations and reliability was examined utilizing generalizability analysis. (4) Relations with other relevant variables were examined by comparing factor scores with other outcomes. Content validity was supported by theory underlying the cognitive apprenticeship model on which the instrument is based. The pilot study resulted in an additional question about supervision time. A five-factor model showed a good fit with the data. Acceptable reliability was achievable with 10-12 questionnaires per teacher. Correlations between the factors and overall teacher judgement were strong. The MCTQ appears to be a valid and reliable instrument to evaluate clinical teachers' performance during short rotations.

  12. Validity and Reliability of a Medicine Ball Explosive Power Test.

    ERIC Educational Resources Information Center

    Stockbrugger, Barry A.; Haennel, Robert G.

    2001-01-01

    Evaluated the validity and reliability of a medicine ball throw test to evaluate explosive power. Data on competitive sand volleyball players who performed a medicine ball throw and a standard countermovement jump indicated that the medicine ball throw test was a valid and reliable way to assess explosive power for an analogous total-body movement…

  13. Test-retest reliability of myofascial trigger point detection in hip and thigh areas.

    PubMed

    Rozenfeld, E; Finestone, A S; Moran, U; Damri, E; Kalichman, L

    2017-10-01

    Myofascial trigger points (MTrP's) are a primary source of pain in patients with musculoskeletal disorders. Nevertheless, they are frequently underdiagnosed. Reliable MTrP palpation is the necessary for their diagnosis and treatment. The few studies that have looked for intra-tester reliability of MTrPs detection in upper body, provide preliminary evidence that MTrP palpation is reliable. Reliability tests for MTrP palpation on the lower limb have not yet been performed. To evaluate inter- and intra-tester reliability of MTrP recognition in hip and thigh muscles. Reliability study. 21 patients (15 males and 6 females, mean age 21.1 years) referred to the physical therapy clinic, 10 with knee or hip pain and 11 with pain in an upper limb, low back, shin or ankle. Two experienced physical therapists performed the examinations, blinded to the subjects' identity, medical condition and results of the previous MTrP evaluation. Each subject was evaluated four times, twice by each examiner in a random order. Dichotomous findings included a palpable taut band, tenderness, referred pain, and relevance of referred pain to patient's complaint. Based on these, diagnosis of latent MTrP's or active MTrP's was established. The evaluation was performed on both legs and included a total of 16 locations in the following muscles: rectus femoris (proximal), vastus medialis (middle and distal), vastus lateralis (middle and distal) and gluteus medius (anterior, posterior and distal). Inter- and intra-tester reliability (Cohen's kappa (κ)) values for single sites ranged from -0.25 to 0.77. Median intra-tester reliability was 0.45 and 0.46 for latent and active MTrP's, and median inter-tester reliability was 0.51 and 0.64 for latent and active MTrPs, respectively. The examination of the distal vastus medialis was most reliable for latent and active MTrP's (intra-tester k = 0.27-0.77, inter-tester k = 0.77 and intra-tester k = 0.53-0.72, inter-tester k = 0.72, correspondingly). Inter- and intra-tester reliability of active and latent MTrP evaluation was moderate to substantial. Palpation evaluation can be used for clinical diagnosis of MTrP's in the hip and thigh muscles. This study provides evidence that MTrP palpation is a moderately reliable diagnostic tool in the hip and thigh muscles and can be used in clinical practice and research. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Reliability and Validity of the Professional Counseling Performance Evaluation

    ERIC Educational Resources Information Center

    Shepherd, J. Brad; Britton, Paula J.; Kress, Victoria E.

    2008-01-01

    The definition and measurement of counsellor trainee competency is an issue that has received increased attention yet lacks quantitative study. This research evaluates item responses, scale reliability and intercorrelations, interrater agreement, and criterion-related validity of the Professional Performance Fitness Evaluation/Professional…

  15. Reliability of the AMA Guides to the Evaluation of Permanent Impairment.

    PubMed

    Forst, Linda; Friedman, Lee; Chukwu, Abraham

    2010-12-01

    AMA's Guides to the Evaluation of Permanent Impairment is used to rate loss of function and determine compensation and ability to work after injury or illness; however, there are few studies that evaluate reliability or construct validity. To evaluate the reliability of the fifth and sixth editions for back injury; to determine best methods for further study. Intra-class correlation coefficients within and between raters were relatively high. There was wider variability for individual cases. Impairment ratings were lower and correlated less well for the sixth edition, though confidence intervals overlapped. The sixth edition may not be an improvement over the fifth. A research agenda should include investigations of reliability and construct validity for different body sites and organ systems along the entire rating scale and among different categories of raters.

  16. Techniques for control of long-term reliability of complex integrated circuits. I - Reliability assurance by test vehicle qualification.

    NASA Technical Reports Server (NTRS)

    Van Vonno, N. W.

    1972-01-01

    Development of an alternate approach to the conventional methods of reliability assurance for large-scale integrated circuits. The product treated is a large-scale T squared L array designed for space applications. The concept used is that of qualification of product by evaluation of the basic processing used in fabricating the product, providing an insight into its potential reliability. Test vehicles are described which enable evaluation of device characteristics, surface condition, and various parameters of the two-level metallization system used. Evaluation of these test vehicles is performed on a lot qualification basis, with the lot consisting of one wafer. Assembled test vehicles are evaluated by high temperature stress at 300 C for short time durations. Stressing at these temperatures provides a rapid method of evaluation and permits a go/no go decision to be made on the wafer lot in a timely fashion.

  17. Objective measurements of excess skin in post bariatric patients--inter-rater reliability.

    PubMed

    Biörserud, Christina; Fagevik Olsén, Monika; Elander, Anna; Wiklund, Malin

    2016-01-01

    An ability to reliably assess excess skin after massive weight loss using well-described and transferrable methods is important. The aim of this trial was to evaluate inter-rater reliability of ptosis and circumference measurements in patients with excess skin after bariatric surgery. Twenty-five postbariatric patients were included in the study, and their excess skin was measured 18 months after surgery. A protocol was designed to measure excess skin in a standardised way. To evaluate the inter-rater reliability in the measuring protocol, all patients were measured twice, by a specialist nurse and a specialist physiotherapist. All circumference measurements on different body parts had an ICC > 0.9, indicating high reliability. Furthermore, all breast and abdominal ptosis measurements had high reliability. In contrast, visual evaluation of abdominal ptosis had poor reliability. Measurements of ptoses on different body parts had an ICC > 0.6. There were no systematic differences between the results of the two testers, except for measurements of the buttocks and maximal knee circumference. The measuring protocol presented in this study has high reliability and, therefore, represents a useful instrument to provide a consistent and objective assessment of excess skin in the postbariatric patient.

  18. Brazilian version of the Protocole Montréal d'Evaluation de la Communication (Protocole MEC): normative and reliability data.

    PubMed

    Fonseca, Rochele Paz; Joanette, Yves; Côté, Hélène; Ska, Bernadette; Giroux, Francine; Fachel, Jandyra Maria Guimarães; Damasceno Ferreira, Gabriela; Parente, Maria Alice de Mattos Pimenta

    2008-11-01

    The lack of standardized instruments to evaluate communication disorders related to the right hemisphere was verified. A new evaluation tool was developed: Protocole Montréal d'Evaluation de la Communication--Protocole MEC, adapted to Brazilian Portuguese--Bateria Montreal de Avaliação da Comunicação--Bateria MAC (Montreal Evaluation of Communication Battery). The purpose was to present stratified normative data by age and educational level, and to verify the reliability parameters of the MEC Battery. 300 individuals, between the ages of 19 and 75 years, and levels of formal education between 2 and 35 years, participated in this study. They were divided equally into six normative groups, according to three age categories (young adults, intermediary age, and seniors) and two educational levels (low and high). Two procedures were used to check reliability: Cronbach alpha and reliability between evaluators, Results were established at the 10th percentile, and an alert point per task for each normative group. Cronbach's alpha was, in general, between .70 and .90 and the average rate of agreement between evaluators varied from .62 to .94. Standards of age and education were established. The reliability of this instrument was verified. The psychometric legitimization of the MEC Battery will contribute to the diagnostic process for communicative disorders.

  19. An Approach to the Lightning Overvoltage Protection of Medium Voltage Lines in Severe Lightning Areas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Omidiora, M. A.; Lehtonen, M.

    2008-05-08

    This paper deals with the effect of shield wires on lightning overvoltage reduction and the energy relief of MOV (Metal Oxide Varistor) arresters from direct strokes to distribution lines. The subject of discussion is the enhancement of lightning protection in Finnish distribution networks where lightning is most severe. The true index of lightning severity in these areas is based on the ground flash densities and return stroke data collected from the Finnish meteorological institute. The presented test case is the IEEE 34-node test feeder injected with multiple lightning strokes and simulated with the Alternative Transients Program/Electromagnetic Transients program (ATP/EMTP). Themore » response of the distribution line to lightning strokes was modeled with three different cases: no protection, protection with surge arresters and protection with a combination of shield wire and arresters. Simulations were made to compare the resulting overvoltages on the line for all the analyzed cases.« less

  20. The Heliosphere in Space

    NASA Astrophysics Data System (ADS)

    Frisch, P. C.; Hanson, A. J.; Fu, P. C.

    2008-12-01

    A scientifically accurate visualization of the Journey of the Sun through deep space has been created in order to share the excitement of heliospheric physics and scientific discovery with the non-expert. The MHD heliosphere model of Linde (1998) displays the interaction of the solar wind with the interstellar medium for a supersonic heliosphere traveling through a low density magnetized interstellar medium. The camera viewpoint follows the solar motion through a virtual space of the Milky Way Galaxy. This space is constructed from real data placed in the three-dimensional solar neighborhood, and populated with Hipparcos stars in front of a precisely aligned image of the Milky Way itself. The celestial audio track of this three minute movie includes the music of the heliosphere, heard by the two Voyager satellites as 3 kHz emissions from the edge of the heliosphere. This short heliosphere visualization can be downloaded from http://www.cs.indiana.edu/~soljourn/pub/AstroBioScene7Sound.mov, and the full scientific data visualization of the Solar Journey is available commercially.

  1. Selective Electrocatalytic Reduction of Nitrite to Dinitrogen Based on Decoupled Proton-Electron Transfer.

    PubMed

    He, Daoping; Li, Yamei; Ooka, Hideshi; Go, Yoo Kyung; Jin, Fangming; Kim, Sun Hee; Nakamura, Ryuhei

    2018-02-14

    The development of denitrification catalysts which can reduce nitrate and nitrite to dinitrogen is critical for sustaining the nitrogen cycle. However, regulating the selectivity has proven to be a challenge, due to the difficulty of controlling complex multielectron/proton reactions. Here we report that utilizing sequential proton-electron transfer (SPET) pathways is a viable strategy to enhance the selectivity of electrochemical reactions. The selectivity of an oxo-molybdenum sulfide electrocatalyst toward nitrite reduction to dinitrogen exhibited a volcano-type pH dependence with a maximum at pH 5. The pH-dependent formation of the intermediate species (distorted Mo(V) oxo species) identified using operando electron paramagnetic resonance (EPR) and Raman spectroscopy was in accord with a mathematical prediction that the pK a of the reaction intermediates determines the pH-dependence of the SPET-derived product. By utilizing this acute pH dependence, we achieved a Faradaic efficiency of 13.5% for nitrite reduction to dinitrogen, which is the highest value reported to date under neutral conditions.

  2. Reliability testing of the Larsen and Sharp classifications for rheumatoid arthritis of the elbow.

    PubMed

    Jew, Nicholas B; Hollins, Anthony M; Mauck, Benjamin M; Smith, Richard A; Azar, Frederick M; Miller, Robert H; Throckmorton, Thomas W

    2017-01-01

    Two popular systems for classifying rheumatoid arthritis affecting the elbow are the Larsen and Sharp schemes. To our knowledge, no study has investigated the reliability of these 2 systems. We compared the intraobserver and interobserver agreement of the 2 systems to determine whether one is more reliable than the other. The radiographs of 45 patients diagnosed with rheumatoid arthritis affecting the elbow were evaluated. Anteroposterior and lateral radiographs were deidentified and distributed to 6 evaluators (4 fellowship-trained upper extremity surgeons and 2 orthopedic trainees). Each evaluator graded all 45 radiographs according to the Larsen and Sharp scoring methods on 2 occasions, at least 2 weeks apart. Overall intraobserver reliability was 0.93 (95% confidence interval [CI], 0.90-0.95) for the Larsen system and 0.92 (95% CI, 0.86-0.96) for the Sharp classification, both indicating substantial agreement. Overall interobserver reliability was 0.70 (95% CI, 0.60-0.80) for the Larsen classification and 0.68 (95% CI, 0.54-0.81) for the Sharp system, both indicating good agreement. There were no significant differences in the intraobserver or interobserver reliability of the systems overall and no significant differences in reliability between attending surgeons and trainees for either classification system. The Larsen and Sharp systems both show substantial intraobserver reliability and good interobserver agreement for the radiographic classification of rheumatoid arthritis affecting the elbow. Differences in training level did not result in substantial variances in reliability for either system. We conclude that both systems can be reliably used to evaluate rheumatoid arthritis of the elbow by observers of varying training levels. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  3. Reliability and performance evaluation of systems containing embedded rule-based expert systems

    NASA Technical Reports Server (NTRS)

    Beaton, Robert M.; Adams, Milton B.; Harrison, James V. A.

    1989-01-01

    A method for evaluating the reliability of real-time systems containing embedded rule-based expert systems is proposed and investigated. It is a three stage technique that addresses the impact of knowledge-base uncertainties on the performance of expert systems. In the first stage, a Markov reliability model of the system is developed which identifies the key performance parameters of the expert system. In the second stage, the evaluation method is used to determine the values of the expert system's key performance parameters. The performance parameters can be evaluated directly by using a probabilistic model of uncertainties in the knowledge-base or by using sensitivity analyses. In the third and final state, the performance parameters of the expert system are combined with performance parameters for other system components and subsystems to evaluate the reliability and performance of the complete system. The evaluation method is demonstrated in the context of a simple expert system used to supervise the performances of an FDI algorithm associated with an aircraft longitudinal flight-control system.

  4. Inter- and intraexaminer reliability of bitewing radiography and near-infrared light transillumination for proximal caries detection and assessment.

    PubMed

    Litzenburger, Friederike; Heck, Katrin; Pitchika, Vinay; Neuhaus, Klaus W; Jost, Fabian N; Hickel, Reinhard; Jablonski-Momeni, Anahita; Welk, Alexander; Lederer, Alexander; Kühnisch, Jan

    2018-02-01

    The purpose of this in vitro study was to evaluate the inter- and intraexaminer reliability of digital bitewing (DBW) radiography and near-infrared light transillumination (NIRT) for proximal caries detection and assessment in posterior teeth. From a pool of 85 patients, 100 corresponding pairs of DBW and NIRT images (~1/3 healthy, ~1/3 with enamel caries and ~1/3 with dentin caries) were chosen. 12 dentists with different professional status and clinical experience repeated the evaluation in two blinded cycles. Two experienced dentists provided a reference diagnosis after analysing all images independently. Statistical analysis included the calculation of simple (κ) and weighted Kappa (wκ) values as a measure of reliability. Logistic regression with a backward elimination model was used to investigate the influence of the diagnostic method, evaluation cycle, type of tooth, and clinical experience on reliability. Altogether, inter- and intraexaminer reliability exhibited good to excellent κ and wκ values for DBW radiography (Inter: κ = 0.60/ 0.63; wκ = 0.74/0.76; Intra: κ = 0.64; wκ = 0.77) and NIRT (Inter: κ = 0.74/0.64; wκ = 0.86/0.82; Intra: κ = 0.68; wκ = 0.84). The backward elimination model revealed NIRT to be significantly more reliable than DBW radiography. This study revealed a good to excellent inter- and intraexaminer reliability for proximal caries detection using DBW and NIRT images. The logistic regression analysis revealed significantly better reliability for NIRT. Additionally, the first evaluation cycle was more reliable according to the reference diagnoses.

  5. Reliability of the Matson Evaluation of Social Skills with Youngsters (MESSY) for Children with Autism Spectrum Disorders

    ERIC Educational Resources Information Center

    Matson, Johnny L.; Horovitz, Max; Mahan, Sara; Fodstad, Jill

    2013-01-01

    The purpose of this paper was to update the psychometrics of the "Matson Evaluation of Social Skills for Youngsters" ("MESSY") with children with Autism Spectrum Disorders (ASD), specifically with respect to internal consistency, split-half reliability, and inter-rater reliability. In Study 1, 114 children with ASD (Autistic Disorder, Asperger's…

  6. Reliability Evaluation for Clustered WSNs under Malware Propagation

    PubMed Central

    Shen, Shigen; Huang, Longjun; Liu, Jianhua; Champion, Adam C.; Yu, Shui; Cao, Qiying

    2016-01-01

    We consider a clustered wireless sensor network (WSN) under epidemic-malware propagation conditions and solve the problem of how to evaluate its reliability so as to ensure efficient, continuous, and dependable transmission of sensed data from sensor nodes to the sink. Facing the contradiction between malware intention and continuous-time Markov chain (CTMC) randomness, we introduce a strategic game that can predict malware infection in order to model a successful infection as a CTMC state transition. Next, we devise a novel measure to compute the Mean Time to Failure (MTTF) of a sensor node, which represents the reliability of a sensor node continuously performing tasks such as sensing, transmitting, and fusing data. Since clustered WSNs can be regarded as parallel-serial-parallel systems, the reliability of a clustered WSN can be evaluated via classical reliability theory. Numerical results show the influence of parameters such as the true positive rate and the false positive rate on a sensor node’s MTTF. Furthermore, we validate the method of reliability evaluation for a clustered WSN according to the number of sensor nodes in a cluster, the number of clusters in a route, and the number of routes in the WSN. PMID:27294934

  7. Reliability Evaluation for Clustered WSNs under Malware Propagation.

    PubMed

    Shen, Shigen; Huang, Longjun; Liu, Jianhua; Champion, Adam C; Yu, Shui; Cao, Qiying

    2016-06-10

    We consider a clustered wireless sensor network (WSN) under epidemic-malware propagation conditions and solve the problem of how to evaluate its reliability so as to ensure efficient, continuous, and dependable transmission of sensed data from sensor nodes to the sink. Facing the contradiction between malware intention and continuous-time Markov chain (CTMC) randomness, we introduce a strategic game that can predict malware infection in order to model a successful infection as a CTMC state transition. Next, we devise a novel measure to compute the Mean Time to Failure (MTTF) of a sensor node, which represents the reliability of a sensor node continuously performing tasks such as sensing, transmitting, and fusing data. Since clustered WSNs can be regarded as parallel-serial-parallel systems, the reliability of a clustered WSN can be evaluated via classical reliability theory. Numerical results show the influence of parameters such as the true positive rate and the false positive rate on a sensor node's MTTF. Furthermore, we validate the method of reliability evaluation for a clustered WSN according to the number of sensor nodes in a cluster, the number of clusters in a route, and the number of routes in the WSN.

  8. Inter-rater reliability of the Sødring Motor Evaluation of Stroke patients (SMES).

    PubMed

    Halsaa, K E; Sødring, K M; Bjelland, E; Finsrud, K; Bautz-Holter, E

    1999-12-01

    The Sødring Motor Evaluation of Stroke patients is an instrument for physiotherapists to evaluate motor function and activities in stroke patients. The rating reflects quality as well as quantity of the patient's unassisted performance within three domains: leg, arm and gross function. The inter-rater reliability of the method was studied in a sample of 30 patients admitted to a stroke rehabilitation unit. Three therapists were involved in the study; two therapists assessed the same patient on two consecutive days in a balanced design. Cohen's weighted kappa and McNemar's test of symmetry were used as measures of item reliability, and the intraclass correlation coefficient was used to express the reliability of the sumscores. For 24 out of 32 items the weighted kappa statistic was excellent (0.75-0.98), while 7 items had a kappa statistic within the range 0.53-0.74 (fair to good). The reliability of one item was poor (0.13). The intraclass correlation coefficient for the three sumscores was 0.97, 0.91 and 0.97. We conclude that the Sødring Motor Evaluation of Stroke patients is a reliable measure of motor function in stroke patients undergoing rehabilitation.

  9. Scale for positive aspects of caregiving experience: development, reliability, and factor structure.

    PubMed

    Kate, N; Grover, S; Kulhara, P; Nehra, R

    2012-06-01

    OBJECTIVE. To develop an instrument (Scale for Positive Aspects of Caregiving Experience [SPACE]) that evaluates positive caregiving experience and assess its psychometric properties. METHODS. Available scales which assess some aspects of positive caregiving experience were reviewed and a 50-item questionnaire with a 5-point rating was constructed. In all, 203 primary caregivers of patients with severe mental disorders were asked to complete the questionnaire. Internal consistency, test-retest reliability, cross-language reliability, split-half reliability, and face validity were evaluated. Principal component factor analysis was run to assess the factorial validity of the scale. RESULTS. The scale developed as part of the study was found to have good internal consistency, test-retest reliability, cross-language reliability, split-half reliability, and face validity. Principal component factor analysis yielded a 4-factor structure, which also had good test-retest reliability and cross-language reliability. There was a strong correlation between the 4 factors obtained. CONCLUSION. The SPACE developed as part of this study has good psychometric properties.

  10. Superior model for fault tolerance computation in designing nano-sized circuit systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singh, N. S. S., E-mail: narinderjit@petronas.com.my; Muthuvalu, M. S., E-mail: msmuthuvalu@gmail.com; Asirvadam, V. S., E-mail: vijanth-sagayan@petronas.com.my

    2014-10-24

    As CMOS technology scales nano-metrically, reliability turns out to be a decisive subject in the design methodology of nano-sized circuit systems. As a result, several computational approaches have been developed to compute and evaluate reliability of desired nano-electronic circuits. The process of computing reliability becomes very troublesome and time consuming as the computational complexity build ups with the desired circuit size. Therefore, being able to measure reliability instantly and superiorly is fast becoming necessary in designing modern logic integrated circuits. For this purpose, the paper firstly looks into the development of an automated reliability evaluation tool based on the generalizationmore » of Probabilistic Gate Model (PGM) and Boolean Difference-based Error Calculator (BDEC) models. The Matlab-based tool allows users to significantly speed-up the task of reliability analysis for very large number of nano-electronic circuits. Secondly, by using the developed automated tool, the paper explores into a comparative study involving reliability computation and evaluation by PGM and, BDEC models for different implementations of same functionality circuits. Based on the reliability analysis, BDEC gives exact and transparent reliability measures, but as the complexity of the same functionality circuits with respect to gate error increases, reliability measure by BDEC tends to be lower than the reliability measure by PGM. The lesser reliability measure by BDEC is well explained in this paper using distribution of different signal input patterns overtime for same functionality circuits. Simulation results conclude that the reliability measure by BDEC depends not only on faulty gates but it also depends on circuit topology, probability of input signals being one or zero and also probability of error on signal lines.« less

  11. Basis And Application Of The CARES/LIFE Computer Program

    NASA Technical Reports Server (NTRS)

    Nemeth, Noel N.; Janosik, Lesley A.; Gyekenyesi, John P.; Powers, Lynn M.

    1996-01-01

    Report discusses physical and mathematical basis of Ceramics Analysis and Reliability Evaluation of Structures LIFE prediction (CARES/LIFE) computer program, described in "Program for Evaluation of Reliability of Ceramic Parts" (LEW-16018).

  12. Evaluation of Human Reliability in Selected Activities in the Railway Industry

    NASA Astrophysics Data System (ADS)

    Sujová, Erika; Čierna, Helena; Molenda, Michał

    2016-09-01

    The article focuses on evaluation of human reliability in the human - machine system in the railway industry. Based on a survey of a train dispatcher and of selected activities, we have identified risk factors affecting the dispatcher`s work and the evaluated risk level of their influence on the reliability and safety of preformed activities. The research took place at the authors` work place between 2012-2013. A survey method was used. With its help, authors were able to identify selected work activities of train dispatcher's risk factors that affect his/her work and the evaluated seriousness of its influence on the reliability and safety of performed activities. Amongst the most important finding fall expressions of unclear and complicated internal regulations and work processes, a feeling of being overworked, fear for one's safety at small, insufficiently protected stations.

  13. Inter- and intraobserver reliability of the vertebral, local and segmental kyphosis in 120 traumatic lumbar and thoracic burst fractures: evaluation in lateral X-rays and sagittal computed tomographies

    PubMed Central

    Brunner, Alexander; Gühring, Markus; Schmälzle, Traude; Weise, Kuno; Badke, Andreas

    2009-01-01

    Evaluation of the kyphosis angle in thoracic and lumbar burst fractures is often used to indicate surgical procedures. The kyphosis angle could be measured as vertebral, segmental and local kyphosis according to the method of Cobb. The vertebral, segmental and local kyphosis according to the method of Cobb were measured at 120 lateral X-rays and sagittal computed tomographies of 60 thoracic and 60 lumbar burst fractures by 3 independent observers on 2 separate occasions. Osteoporotic fractures were excluded. The intra- and interobserver reliability of these angles in X-ray and computed tomogram, using the intra class correlation coefficient (ICC) were evaluated. Highest reproducibility showed the segmental kyphosis followed by the vertebral kyphosis. For thoracic fractures segmental kyphosis shows in X-ray “excellent” inter- and intraobserver reliabilities (ICC 0.826, 0.802) and for lumbar fractures “good” to “excellent” inter- and intraobserver reliabilities (ICC = 0.790, 0.803). In computed tomography, the segmental kyphosis showed “excellent” inter- and intraobserver reliabilities (ICC = 0.824, 0.801) for thoracic and “excellent” inter- and intraobserver reliabilities (ICC = 0.874, 0.835) for the lumbar fractures. Regarding both diagnostic work ups (X-ray and computed tomography), significant differences were evaluated in interobserver reliabilities for vertebral kyphosis measured in lumbar fracture X-rays (p = 0.035) and interobserver reliabilities for local kyphosis, measured in thoracic fracture X-rays (p = 0.010). Regarding both fracture localizations (thoracic and lumbar fractures), significant differences could only be evaluated in interobserver reliabilities for the local kyphosis measured in computed tomographies (p = 0.045) and in intraobserver reliabilities for the vertebral kyphosis measured in X-rays (p = 0.024). “Good” to “excellent” inter- and intraobserver reliabilities for vertebral, segmental and local kyphosis in X-ray make these angles to a helpful tool, indicating surgical procedures. For the practical use in lateral X-ray, we emphasize the determination of the segmental kyphosis, because of the highest reproducibility of this angle. “Good” to “excellent” inter- and intraobserver reliabilities for these three angles could also be evaluated in computed tomographies. Therefore, also in computed tomography, the use of these three angles seems to be generally possible. For a direct correlation of the results in lateral X-ray and in computed tomography, further studies should be needed. PMID:19953277

  14. Interrater Reliability of mHealth App Rating Measures: Analysis of Top Depression and Smoking Cessation Apps.

    PubMed

    Powell, Adam C; Torous, John; Chan, Steven; Raynor, Geoffrey Stephen; Shwarts, Erik; Shanahan, Meghan; Landman, Adam B

    2016-02-10

    There are over 165,000 mHealth apps currently available to patients, but few have undergone an external quality review. Furthermore, no standardized review method exists, and little has been done to examine the consistency of the evaluation systems themselves. We sought to determine which measures for evaluating the quality of mHealth apps have the greatest interrater reliability. We identified 22 measures for evaluating the quality of apps from the literature. A panel of 6 reviewers reviewed the top 10 depression apps and 10 smoking cessation apps from the Apple iTunes App Store on these measures. Krippendorff's alpha was calculated for each of the measures and reported by app category and in aggregate. The measure for interactiveness and feedback was found to have the greatest overall interrater reliability (alpha=.69). Presence of password protection (alpha=.65), whether the app was uploaded by a health care agency (alpha=.63), the number of consumer ratings (alpha=.59), and several other measures had moderate interrater reliability (alphas>.5). There was the least agreement over whether apps had errors or performance issues (alpha=.15), stated advertising policies (alpha=.16), and were easy to use (alpha=.18). There were substantial differences in the interrater reliabilities of a number of measures when they were applied to depression versus smoking apps. We found wide variation in the interrater reliability of measures used to evaluate apps, and some measures are more robust across categories of apps than others. The measures with the highest degree of interrater reliability tended to be those that involved the least rater discretion. Clinical quality measures such as effectiveness, ease of use, and performance had relatively poor interrater reliability. Subsequent research is needed to determine consistent means for evaluating the performance of apps. Patients and clinicians should consider conducting their own assessments of apps, in conjunction with evaluating information from reviews.

  15. Interrater Reliability of mHealth App Rating Measures: Analysis of Top Depression and Smoking Cessation Apps

    PubMed Central

    Chan, Steven; Raynor, Geoffrey Stephen; Shwarts, Erik; Shanahan, Meghan; Landman, Adam B

    2016-01-01

    Background There are over 165,000 mHealth apps currently available to patients, but few have undergone an external quality review. Furthermore, no standardized review method exists, and little has been done to examine the consistency of the evaluation systems themselves. Objective We sought to determine which measures for evaluating the quality of mHealth apps have the greatest interrater reliability. Methods We identified 22 measures for evaluating the quality of apps from the literature. A panel of 6 reviewers reviewed the top 10 depression apps and 10 smoking cessation apps from the Apple iTunes App Store on these measures. Krippendorff’s alpha was calculated for each of the measures and reported by app category and in aggregate. Results The measure for interactiveness and feedback was found to have the greatest overall interrater reliability (alpha=.69). Presence of password protection (alpha=.65), whether the app was uploaded by a health care agency (alpha=.63), the number of consumer ratings (alpha=.59), and several other measures had moderate interrater reliability (alphas>.5). There was the least agreement over whether apps had errors or performance issues (alpha=.15), stated advertising policies (alpha=.16), and were easy to use (alpha=.18). There were substantial differences in the interrater reliabilities of a number of measures when they were applied to depression versus smoking apps. Conclusions We found wide variation in the interrater reliability of measures used to evaluate apps, and some measures are more robust across categories of apps than others. The measures with the highest degree of interrater reliability tended to be those that involved the least rater discretion. Clinical quality measures such as effectiveness, ease of use, and performance had relatively poor interrater reliability. Subsequent research is needed to determine consistent means for evaluating the performance of apps. Patients and clinicians should consider conducting their own assessments of apps, in conjunction with evaluating information from reviews. PMID:26863986

  16. Accuracy, reliability, and timing of visual evaluations of decay in fresh-cut lettuce

    USDA-ARS?s Scientific Manuscript database

    Visual assessments are used for evaluating the quality of food products, such as fresh-cut lettuce packaged in bags with modified atmosphere. We have compared the accuracy and the reliability of visual evaluations of decay on fresh-cut lettuce performed with experienced and inexperienced raters. In ...

  17. Inter-rater Reliability of Sustained Aberrant Movement Patterns as a Clinical Assessment of Muscular Fatigue

    PubMed Central

    Aerts, Frank; Carrier, Kathy; Alwood, Becky

    2016-01-01

    Background: The assessment of clinical manifestation of muscle fatigue is an effective procedure in establishing therapeutic exercise dose. Few studies have evaluated physical therapist reliability in establishing muscle fatigue through detection of changes in quality of movement patterns in a live setting. Objective: The purpose of this study is to evaluate the inter-rater reliability of physical therapists’ ability to detect altered movement patterns due to muscle fatigue. Design: A reliability study in a live setting with multiple raters. Participants: Forty-four healthy individuals (ages 19-35) were evaluated by six physical therapists in a live setting. Methods: Participants were evaluated by physical therapists for altered movement patterns during resisted shoulder rotation. Each participant completed a total of four tests: right shoulder internal rotation, right shoulder external rotation, left shoulder internal rotation and left shoulder external rotation. Results: For all tests combined, the inter-rater reliability for a single rater scoring ICC (2,1) was .65 (95%, .60, .71) This corresponds to moderate inter-rater reliability between physical therapists. Limitations: The results of this study apply only to healthy participants and therefore cannot be generalized to a symptomatic population. Conclusion: Moderate inter-rater reliability was found between physical therapists in establishing muscle fatigue through the observation of sustained altered movement patterns during dynamic resistive shoulder internal and external rotation. PMID:27347241

  18. On Some Methods in Safety Evaluation in Geotechnics

    NASA Astrophysics Data System (ADS)

    Puła, Wojciech; Zaskórski, Łukasz

    2015-06-01

    The paper demonstrates how the reliability methods can be utilised in order to evaluate safety in geotechnics. Special attention is paid to the so-called reliability based design that can play a useful and complementary role to Eurocode 7. In the first part, a brief review of first- and second-order reliability methods is given. Next, two examples of reliability-based design are demonstrated. The first one is focussed on bearing capacity calculation and is dedicated to comparison with EC7 requirements. The second one analyses a rigid pile subjected to lateral load and is oriented towards working stress design method. In the second part, applications of random field to safety evaluations in geotechnics are addressed. After a short review of the theory a Random Finite Element algorithm to reliability based design of shallow strip foundation is given. Finally, two illustrative examples for cohesive and cohesionless soils are demonstrated.

  19. Meta-analytic guidelines for evaluating single-item reliabilities of personality instruments.

    PubMed

    Spörrle, Matthias; Bekk, Magdalena

    2014-06-01

    Personality is an important predictor of various outcomes in many social science disciplines. However, when personality traits are not the principal focus of research, for example, in global comparative surveys, it is often not possible to assess them extensively. In this article, we first provide an overview of the advantages and challenges of single-item measures of personality, a rationale for their construction, and a summary of alternative ways of assessing their reliability. Second, using seven diverse samples (Ntotal = 4,263) we develop the SIMP-G, the German adaptation of the Single-Item Measures of Personality, an instrument assessing the Big Five with one item per trait, and evaluate its validity and reliability. Third, we integrate previous research and our data into a first meta-analysis of single-item reliabilities of personality measures, and provide researchers with guidelines and recommendations for the evaluation of single-item reliabilities. © The Author(s) 2013.

  20. Evaluating information skills training in health libraries: a systematic review.

    PubMed

    Brettle, Alison

    2007-12-01

    Systematic reviews have shown that there is limited evidence to demonstrate that the information literacy training health librarians provide is effective in improving clinicians' information skills or has an impact on patient care. Studies lack measures which demonstrate validity and reliability in evaluating the impact of training. To determine what measures have been used; the extent to which they are valid and reliable; to provide guidance for health librarians who wish to evaluate the impact of their information skills training. Systematic review methodology involved searching seven databases, and personal files. Studies were included if they were about information skills training, used an objective measure to assess outcomes, and occurred in a health setting. Fifty-four studies were included in the review. Most outcome measures used in the studies were not tested for the key criteria of validity and reliability. Three tested for validity and reliability are described in more detail. Selecting an appropriate measure to evaluate the impact of training is a key factor in carrying out any evaluation. This systematic review provides guidance to health librarians by highlighting measures used in various circumstances, and those that demonstrate validity and reliability.

  1. Investigation of thermodynamic properties of metal-oxide catalysts

    NASA Astrophysics Data System (ADS)

    Shah, Parag Rasiklal

    An apparatus for Coulometric Titration was developed and used to measure the redox isotherms (i.e. oxygen fugacity P(O2) vs oxygen stoichiometry) of ceria-zirconia solid solutions, mixed oxides of vanadia, and vanadia supported on ZrO2. This data was used to correlate the redox thermodynamics of these oxides to their structure and catalytic properties. From the redox isotherms measured between 873 K and 973 K, the differential enthalpies of oxidation (DeltaH) for Ce0.81Zr0.19O 2.0 and Ce0.25Zr0.75O2.0 were determined, and they were found to be independent of extent of reduction or composition of the solid solution. They were also lower than DeltaH for ceria, which explains the better redox properties of ceria-zirconia solid solutions. The oxidation was driven by entropy in the low reduction region, and a structural model was proposed to explain the observed entropy effects. Redox isotherms were also measured for a number of bulk vanadates between 823 K and 973 K. DeltaG, DeltaH and DeltaS were reported for V 2O5, Mg3(VO4)2, CeVO 4 and ZrV2O7 along with DeltaG values for AlVO 4, LaVO4, CrVO4. V2O5 and ZrV2O7, which were the only oxides having V-O-V bonds, showed a two-step transition of vanadium for V+3↔V +4 and V+4↔V+5 equilibrium in the redox isotherms. The other oxides, all of which have only M-O-V (M=cation other than V), showed a direct one-step transition, V+3↔V +5. The nature of the M-atom also influenced the P(O2) at which the V+3↔V+5 transition occurs. Redox isotherms at 748 K were measured for vanadia supported on ZrO 2; with two different vanadia loadings corresponding to isolated vanadyls and polymeric vanadyls. The isotherm for the sample with isolated vanadyls showed a single-step transition, similar to the one seen in bulk vanadates with M-O-V linkages, while no such one-step transition was observed in the isotherm of the other sample. To study the affect of the varying redox properties of the vanadium-based catalysts on oxidation rates, kinetic studies were performed for methanol and propane oxidation reactions on some of these catalysts. The results suggested that there was no effect of thermodynamic properties of these catalysts on the rates of these oxidation reactions.

  2. Test-retest and interrater reliability of the functional lower extremity evaluation.

    PubMed

    Haitz, Karyn; Shultz, Rebecca; Hodgins, Melissa; Matheson, Gordon O

    2014-12-01

    Repeated-measures clinical measurement reliability study. To establish the reliability and face validity of the Functional Lower Extremity Evaluation (FLEE). The FLEE is a 45-minute battery of 8 standardized functional performance tests that measures 3 components of lower extremity function: control, power, and endurance. The reliability and normative values for the FLEE in healthy athletes are unknown. A face validity survey for the FLEE was sent to sports medicine personnel to evaluate the level of importance and frequency of clinical usage of each test included in the FLEE. The FLEE was then administered and rated for 40 uninjured athletes. To assess test-retest reliability, each athlete was tested twice, 1 week apart, by the same rater. To assess interrater reliability, 3 raters scored each athlete during 1 of the testing sessions. Intraclass correlation coefficients were used to assess the test-retest and interrater reliability of each of the FLEE tests. In the face validity survey, the FLEE tests were rated as highly important by 58% to 71% of respondents but frequently used by only 26% to 45% of respondents. Interrater reliability intraclass correlation coefficients ranged from 0.83 to 1.00, and test-retest reliability ranged from 0.71 to 0.95. The FLEE tests are considered clinically important for assessing lower extremity function by sports medicine personnel but are underused. The FLEE also is a reliable assessment tool. Future studies are required to determine if use of the FLEE to make return-to-play decisions may reduce reinjury rates.

  3. A Reliability and Validity of an Instrument to Evaluate the School-Based Assessment System: A Pilot Study

    ERIC Educational Resources Information Center

    Ghazali, Nor Hasnida Md

    2016-01-01

    A valid, reliable and practical instrument is needed to evaluate the implementation of the school-based assessment (SBA) system. The aim of this study is to develop and assess the validity and reliability of an instrument to measure the perception of teachers towards the SBA implementation in schools. The instrument is developed based on a…

  4. Reliability of joint count assessment in rheumatoid arthritis: a systematic literature review.

    PubMed

    Cheung, Peter P; Gossec, Laure; Mak, Anselm; March, Lyn

    2014-06-01

    Joint counts are central to the assessment of rheumatoid arthritis (RA) but reliability is an issue. To evaluate the reliability and agreement of joint counts (intra-observer and inter-observer) by health care professionals (physicians, nurses, and metrologists) and patients in RA, and the impact of training and standardization on joint count reliability through a systematic literature review. Articles reporting joint count reliability or agreement in RA in PubMed, EMBase, and the Cochrane library between 1960 and 2012 were selected. Data were extracted regarding tender joint counts (TJCs) and swollen joint counts (SJCs) derived by physicians, metrologists, or patients for intra-observer and inter-observer reliability. In addition, methods and effects of training or standardization were extracted. Statistics expressing reliability such as intraclass correlation coefficients (ICCs) were extracted. Data analysis was primarily descriptive due to high heterogeneity. Twenty-eight studies on health care professionals (HCP) and 20 studies on patients were included. Intra-observer reliability for TJCs and SJCs was good for HCPs and patients (range of ICC: 0.49-0.98). Inter-observer reliability between HCPs for TJCs was higher than for SJCs (range of ICC: 0.64-0.88 vs. 0.29-0.98). Patient inter-observer reliability with HCPs as comparators was better for TJCs (range of ICC: 0.31-0.91) compared to SJCs (0.16-0.64). Nine studies (7 with HCPs and 2 with patients) evaluated consensus or training, with improvement in reliability of TJCs but conflicting evidence for SJCs. Intra- and inter-observer reliability was high for TJCs for HCPs and patients: among all groups, reliability was better for TJCs than SJCs. Inter-observer reliability of SJCs was poorer for patients than HCPs. Data were inconclusive regarding the potential for training to improve SJC reliability. Overall, the results support further evaluation for patient-reported joint counts as an outcome measure. © 2013 Published by Elsevier Inc.

  5. Reliability Generalization of the Alcohol Use Disorder Identification Test.

    ERIC Educational Resources Information Center

    Shields, Alan L.; Caruso, John C.

    2002-01-01

    Evaluated the reliability of scores from the Alcohol Use Disorders Identification Test (AUDIT; J. Sounders and others, 1993) in a reliability generalization study based on 17 empirical journal articles. Results show AUDIT scores to be generally reliable for basic assessment. (SLD)

  6. Measuring Educators' Attitudes and Beliefs about Evaluation: Construct Validity and Reliability of the Teacher Evaluation Experience Scale

    ERIC Educational Resources Information Center

    Reddy, Linda A.; Dudek, Christopher M.; Kettler, Ryan J.; Kurz, Alexander; Peters, Stephanie

    2016-01-01

    This study presents the reliability and validity of the Teacher Evaluation Experience Scale--Teacher Form (TEES-T), a multidimensional measure of educators' attitudes and beliefs about teacher evaluation. Confirmatory factor analyses of data from 583 teachers were conducted on the TEES-T hypothesized five-factor model, as well as on alternative…

  7. Translation, adaptation and inter-rater reliability of the administration manual for the Fugl-Meyer assessment.

    PubMed

    Michaelsen, Stella M; Rocha, André S; Knabben, Rodrigo J; Rodrigues, Luciano P; Fernandes, Claudia G C

    2011-01-01

    Recently, the reliability of the Brazilian version of the Fugl-Meyer Assessment (FMA) was assessed through the scoring given according to observations made by a single evaluator who applied the test. When different raters apply the scale, the reliability may depend on the interpretation given to the assessment sheet. In such cases, a clear administration manual is essential for ensuring homogeneity of application. To translate and adapt the French Canadian version of the FMA administration manual into Brazilian Portuguese and to evaluate the inter-rater reliability when different evaluators apply the FMA on the basis of the information contained in the manual. Eighteen adults (59±10 years) with chronic hemiparesis (38±35 months after a stroke) took part in this study. Eight patients participated in the first part of the study and 10 in the second part. Based on analyzing the results from part 1, an adapted version was developed, in which information and photos were added to illustrate the positions of the patient and evaluator. The inter-rater reliability was assessed using the intraclass correlation coefficient (ICC). The reliability of the FMA based on the adapted version of the manual was excellent for the total motor scores for the upper limbs (ICC=0.98) and lower limbs (ICC=0.90), as well as for movement sense (ICC=0.98) and upper and lower-limb passive range of motion (ICC=0.84 and 0.90, respectively). The reliability was moderate for tactile sensitivity (0.75). The joint pain assessment presented low reliability. The results showed that, except for pain assessment, application of the FMA based on the adapted version of the application manual for Brazilian Portuguese presented adequate inter-rater reliability.

  8. Evaluative frailty index for physical activity (EFIP): a reliable and valid instrument to measure changes in level of frailty.

    PubMed

    de Vries, Nienke M; Staal, J Bart; Olde Rikkert, Marcel G M; Nijhuis-van der Sanden, Maria W G

    2013-04-01

    Physical activity is assumed to be important in the prevention and treatment of frailty. It is unclear, however, to what extent frailty can be influenced because instruments designed to assess frailty have not been validated as evaluative outcome instruments in clinical practice. The aims of this study were: (1) to develop a frailty index (i.e., the evaluative frailty index for physical activity [EFIP]) based on the method of deficit accumulation and (2) to test the clinimetric properties of the EFIP. The content of the EFIP was determined using a written Delphi procedure. Intrarater reliability, interrater reliability, and construct validity were determined in an observational study (n=24). Intrarater reliability and interrater reliability were calculated using Cohen kappa and intraclass correlation coefficients (ICCs). Construct validity was determined by correlating the score on the EFIP with those on the timed "up & go" test (TUG), the performance-oriented mobility assessment (POMA), and the Cumulative Illness Rating Scale for Geriatrics (CIRS-G). Fifty items were included in the EFIP. Interrater reliability (Cohen kappa=0.72, ICC=.96) and intrarater reliability (Cohen kappa=0.77 and 0.80, ICC=.93 and .98) were good. As expected, a fair to moderate correlation with the TUG, POMA, and CIRS-G was found (.61, -.70, and .66, respectively). Reliability and validity of the EFIP have been tested in a small sample. These and other clinimetric properties, such as responsiveness, will be assessed or reassessed in a larger study population. The EFIP is a reliable and valid instrument to evaluate the effect of physical activity on frailty in research and in clinical practice.

  9. The reliability of physical examination tests for the diagnosis of anterior cruciate ligament rupture--A systematic review.

    PubMed

    Lange, Toni; Freiberg, Alice; Dröge, Patrik; Lützner, Jörg; Schmitt, Jochen; Kopkow, Christian

    2015-06-01

    Systematic literature review. Despite their frequent application in routine care, a systematic review on the reliability of clinical examination tests to evaluate the integrity of the ACL is missing. To summarize and evaluate intra- and interrater reliability research on physical examination tests used for the diagnosis of ACL tears. A comprehensive systematic literature search was conducted in MEDLINE, EMBASE and AMED until May 30th 2013. Studies were included if they assessed the intra- and/or interrater reliability of physical examination tests for the integrity of the ACL. Methodological quality was evaluated with the Quality Appraisal of Reliability Studies (QAREL) tool by two independent reviewers. 110 hits were achieved of which seven articles finally met the inclusion criteria. These studies examined the reliability of four physical examination tests. Intrarater reliability was assessed in three studies and ranged from fair to almost perfect (Cohen's k = 0.22-1.00). Interrater reliability was assessed in all included studies and ranged from slight to almost perfect (Cohen's k = 0.02-0.81). The Lachman test is the physical tests with the highest intrarater reliability (Cohen's k = 1.00), the Lachman test performed in prone position the test with the highest interrater reliability (Cohen's k = 0.81). Included studies were partly of low methodological quality. A meta-analysis could not be performed due to the heterogeneity in study populations, reliability measures and methodological quality of included studies. Systematic investigations on the reliability of physical examination tests to assess the integrity of the ACL are scarce and of varying methodological quality. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. An accurate and efficient reliability-based design optimization using the second order reliability method and improved stability transformation method

    NASA Astrophysics Data System (ADS)

    Meng, Zeng; Yang, Dixiong; Zhou, Huanlin; Yu, Bo

    2018-05-01

    The first order reliability method has been extensively adopted for reliability-based design optimization (RBDO), but it shows inaccuracy in calculating the failure probability with highly nonlinear performance functions. Thus, the second order reliability method is required to evaluate the reliability accurately. However, its application for RBDO is quite challenge owing to the expensive computational cost incurred by the repeated reliability evaluation and Hessian calculation of probabilistic constraints. In this article, a new improved stability transformation method is proposed to search the most probable point efficiently, and the Hessian matrix is calculated by the symmetric rank-one update. The computational capability of the proposed method is illustrated and compared to the existing RBDO approaches through three mathematical and two engineering examples. The comparison results indicate that the proposed method is very efficient and accurate, providing an alternative tool for RBDO of engineering structures.

  11. Reliability of Wireless Sensor Networks

    PubMed Central

    Dâmaso, Antônio; Rosa, Nelson; Maciel, Paulo

    2014-01-01

    Wireless Sensor Networks (WSNs) consist of hundreds or thousands of sensor nodes with limited processing, storage, and battery capabilities. There are several strategies to reduce the power consumption of WSN nodes (by increasing the network lifetime) and increase the reliability of the network (by improving the WSN Quality of Service). However, there is an inherent conflict between power consumption and reliability: an increase in reliability usually leads to an increase in power consumption. For example, routing algorithms can send the same packet though different paths (multipath strategy), which it is important for reliability, but they significantly increase the WSN power consumption. In this context, this paper proposes a model for evaluating the reliability of WSNs considering the battery level as a key factor. Moreover, this model is based on routing algorithms used by WSNs. In order to evaluate the proposed models, three scenarios were considered to show the impact of the power consumption on the reliability of WSNs. PMID:25157553

  12. The water balance questionnaire: design, reliability and validity of a questionnaire to evaluate water balance in the general population.

    PubMed

    Malisova, Olga; Bountziouka, Vassiliki; Panagiotakos, Demosthenes B; Zampelas, Antonis; Kapsokefalou, Maria

    2012-03-01

    There is a need to develop a questionnaire as a research tool for the evaluation of water balance in the general population. The water balance questionnaire (WBQ) was designed to evaluate water intake from fluid and solid foods and drinking water, and water loss from urine, faeces and sweat at sedentary conditions and physical activity. For validation purposes, the WBQ was administrated in 40 apparently healthy participants aged 22-57 years (37.5% males). Hydration indices in urine (24 h volume, osmolality, specific gravity, pH, colour) were measured through established procedures. Furthermore, the questionnaire was administered twice to 175 subjects to evaluate its reliability. Kendall's τ-b and the Bland and Altman method were used to assess the questionnaire's validity and reliability. The proposed WBQ to assess water balance in healthy individuals was found to be valid and reliable, and it could thus be a useful tool in future projects that aim to evaluate water balance.

  13. Effect of cow reference group on validation reliability of genomic evaluation.

    PubMed

    Koivula, M; Strandén, I; Aamand, G P; Mäntysaari, E A

    2016-06-01

    We studied the effect of including genomic data for cows in the reference population of single-step evaluations. Deregressed individual cow genetic evaluations (DRP) from milk production evaluations of Nordic Red Dairy cattle were used to estimate the single-step breeding values. Validation reliability and bias of the evaluations were calculated with four data sets including different amount of DRP record information from genotyped cows in the reference population. The gain in reliability was from 2% to 4% units for the production traits, depending on the used DRP data and the amount of genomic data. Moreover, inclusion of genotyped bull dams and their genotyped daughters seemed to create some bias in the single-step evaluation. Still, genotyping cows and their inclusion in the reference population is advantageous and should be encouraged.

  14. Updating the reference population to achieve constant genomic prediction reliability across generations.

    PubMed

    Pszczola, M; Calus, M P L

    2016-06-01

    The reliability of genomic breeding values (DGV) decays over generations. To keep the DGV reliability at a constant level, the reference population (RP) has to be continuously updated with animals from new generations. Updating RP may be challenging due to economic reasons, especially for novel traits involving expensive phenotyping. Therefore, the goal of this study was to investigate a minimal RP update size to keep the reliability at a constant level across generations. We used a simulated dataset resembling a dairy cattle population. The trait of interest was not included itself in the selection index, but it was affected by selection pressure by being correlated with an index trait that represented the overall breeding goal. The heritability of the index trait was assumed to be 0.25 and for the novel trait the heritability equalled 0.2. The genetic correlation between the two traits was 0.25. The initial RP (n=2000) was composed of cows only with a single observation per animal. Reliability of DGV using the initial RP was computed by evaluating contemporary animals. Thereafter, the RP was used to evaluate animals which were one generation younger from the reference individuals. The drop in the reliability when evaluating younger animals was then assessed and the RP was updated to re-gain the initial reliability. The update animals were contemporaries of evaluated animals (EVA). The RP was updated in batches of 100 animals/update. First, the animals most closely related to the EVA were chosen to update RP. The results showed that, approximately, 600 animals were needed every generation to maintain the DGV reliability at a constant level across generations. The sum of squared relationships between RP and EVA and the sum of off-diagonal coefficients of the inverse of the genomic relationship matrix for RP, separately explained 31% and 34%, respectively, of the variation in the reliability across generations. Combined, these parameters explained 53% of the variation in the reliability across generations. Thus, for an optimal RP update an algorithm considering both relationships between reference and evaluated animals, as well as relationships among reference animals, is required.

  15. Infant polysomnography: reliability and validity of infant arousal assessment.

    PubMed

    Crowell, David H; Kulp, Thomas D; Kapuniai, Linda E; Hunt, Carl E; Brooks, Lee J; Weese-Mayer, Debra E; Silvestri, Jean; Ward, Sally Davidson; Corwin, Michael; Tinsley, Larry; Peucker, Mark

    2002-10-01

    Infant arousal scoring based on the Atlas Task Force definition of transient EEG arousal was evaluated to determine (1). whether transient arousals can be identified and assessed reliably in infants and (2). whether arousal and no-arousal epochs scored previously by trained raters can be validated reliably by independent sleep experts. Phase I for inter- and intrarater reliability scoring was based on two datasets of sleep epochs selected randomly from nocturnal polysomnograms of healthy full-term, preterm, idiopathic apparent life-threatening event cases, and siblings of Sudden Infant Death Syndrome infants of 35 to 64 weeks postconceptional age. After training, test set 1 reliability was assessed and discrepancies identified. After retraining, test set 2 was scored by the same raters to determine interrater reliability. Later, three raters from the trained group rescored test set 2 to assess inter- and intrarater reliabilities. Interrater and intrarater reliability kappa's, with 95% confidence intervals, ranged from substantial to almost perfect levels of agreement. Interrater reliabilities for spontaneous arousals were initially moderate and then substantial. During the validation phase, 315 previously scored epochs were presented to four sleep experts to rate as containing arousal or no-arousal events. Interrater expert agreements were diverse and considered as noninterpretable. Concordance in sleep experts' agreements, based on identification of the previously sampled arousal and no-arousal epochs, was used as a secondary evaluative technique. Results showed agreement by two or more experts on 86% of the Collaborative Home Infant Monitoring Evaluation Study arousal scored events. Conversely, only 1% of the Collaborative Home Infant Monitoring Evaluation Study-scored no-arousal epochs were rated as an arousal. In summary, this study presents an empirically tested model with procedures and criteria for attaining improved reliability in transient EEG arousal assessments in infants using the modified Atlas Task Force standards. With training based on specific criteria, substantial inter- and intrarater agreement in identifying infant arousals was demonstrated. Corroborative validation results were too disparate for meaningful interpretation. Alternate evaluation based on concordance agreements supports reliance on infant EEG criteria for assessment. Results mandate additional confirmatory validation studies with specific training on infant EEG arousal assessment criteria.

  16. Multi-state time-varying reliability evaluation of smart grid with flexible demand resources utilizing Lz transform

    NASA Astrophysics Data System (ADS)

    Jia, Heping; Jin, Wende; Ding, Yi; Song, Yonghua; Yu, Dezhao

    2017-01-01

    With the expanding proportion of renewable energy generation and development of smart grid technologies, flexible demand resources (FDRs) have been utilized as an approach to accommodating renewable energies. However, multiple uncertainties of FDRs may influence reliable and secure operation of smart grid. Multi-state reliability models for a single FDR and aggregating FDRs have been proposed in this paper with regard to responsive abilities for FDRs and random failures for both FDR devices and information system. The proposed reliability evaluation technique is based on Lz transform method which can formulate time-varying reliability indices. A modified IEEE-RTS has been utilized as an illustration of the proposed technique.

  17. Reliability of adherence and competence assessment in cognitive behavioral therapy: influence of clinical experience.

    PubMed

    Weck, Florian; Hilling, Christine; Schermelleh-Engel, Karin; Rudari, Visar; Stangier, Ulrich

    2011-04-01

    The use of highly experienced expert judges was suggested for the assessment of therapists' adherence and competence. However, such an approach implies high costs. It can be questioned whether only experts are able to evaluate therapists' adherence and competence reliably. To test this, 4 judges evaluated therapist adherence and competence in 30 randomly selected videotapes of cognitive therapy sessions for depression. In that, 2 judges exhibited high clinical experience (experts), whereas 2 judges did not (novices). We could demonstrate that novices evaluated an aggregated adherence and competence measure with high reliability. However, several adherence and competence aspects were not assessed with satisfactory reliability by novices. Although adherence ratings of experts and novices showed high concordance, the concordance of competence ratings was only moderate. Results revealed that therapists' adherence could be evaluated satisfactorily by trained novices with some restrictions, but not their competence.

  18. Integrated Evaluation of Reliability and Power Consumption of Wireless Sensor Networks.

    PubMed

    Dâmaso, Antônio; Rosa, Nelson; Maciel, Paulo

    2017-11-05

    Power consumption is a primary interest in Wireless Sensor Networks (WSNs), and a large number of strategies have been proposed to evaluate it. However, those approaches usually neither consider reliability issues nor the power consumption of applications executing in the network. A central concern is the lack of consolidated solutions that enable us to evaluate the power consumption of applications and the network stack also considering their reliabilities. To solve this problem, we introduce a fully automatic solution to design power consumption aware WSN applications and communication protocols. The solution presented in this paper comprises a methodology to evaluate the power consumption based on the integration of formal models, a set of power consumption and reliability models, a sensitivity analysis strategy to select WSN configurations and a toolbox named EDEN to fully support the proposed methodology. This solution allows accurately estimating the power consumption of WSN applications and the network stack in an automated way.

  19. Confirmatory Factor Analysis of the System for Evaluation of Teaching Qualities (SETQ) in Graduate Medical Training.

    PubMed

    Boerebach, Benjamin C M; Lombarts, Kiki M J M H; Arah, Onyebuchi A

    2016-03-01

    The System for Evaluation of Teaching Qualities (SETQ) was developed as a formative system for the continuous evaluation and development of physicians' teaching performance in graduate medical training. It has been seven years since the introduction and initial exploratory psychometric analysis of the SETQ questionnaires. This study investigates the validity and reliability of the SETQ questionnaires across hospitals and medical specialties using confirmatory factor analyses (CFAs), reliability analysis, and generalizability analysis. The SETQ questionnaires were tested in a sample of 3,025 physicians and 2,848 trainees in 46 hospitals. The CFA revealed acceptable fit of the data to the previously identified five-factor model. The high internal consistency estimates suggest satisfactory reliability of the subscales. These results provide robust evidence for the validity and reliability of the SETQ questionnaires for evaluating physicians' teaching performance. © The Author(s) 2014.

  20. The reliability of a simplified water displacement instrument: a method for measuring arm volume.

    PubMed

    Sagen, Ase; Kåresen, Rolf; Risberg, May Arna

    2005-01-01

    To present a new water displacement measurement, the Simplified Water Displacement Instrument (SWDI), and to evaluate its intra- and intertester reliability. Reliability design. Hospital setting. Fifty-six healthy people were studied. Intratester reliability was evaluated once a week for 4 weeks in 20 women and 10 men. Intertester reliability was assessed by 2 physical therapists in 26 people. Not applicable. Coefficients of variation (CVs) and intraclass correlation coefficients (ICCs). The intratester reliability showed a CV range of 2.2% to 2.6% and an ICC range of .98 to .99. The intertester reliability showed a CV of 1.3% and an ICC of .99. There was a significant increase in arm volume in men compared with women. There were no significant differences in changes in volume over the 4 weeks. There was a significant greater right arm volume (3.3%) among the right-handed subjects (P<.001). Both intra- and intertester reliability were satisfactory for the SWDI.

  1. ASSESSING AND COMBINING RELIABILITY OF PROTEIN INTERACTION SOURCES

    PubMed Central

    LEACH, SONIA; GABOW, AARON; HUNTER, LAWRENCE; GOLDBERG, DEBRA S.

    2008-01-01

    Integrating diverse sources of interaction information to create protein networks requires strategies sensitive to differences in accuracy and coverage of each source. Previous integration approaches calculate reliabilities of protein interaction information sources based on congruity to a designated ‘gold standard.’ In this paper, we provide a comparison of the two most popular existing approaches and propose a novel alternative for assessing reliabilities which does not require a gold standard. We identify a new method for combining the resultant reliabilities and compare it against an existing method. Further, we propose an extrinsic approach to evaluation of reliability estimates, considering their influence on the downstream tasks of inferring protein function and learning regulatory networks from expression data. Results using this evaluation method show 1) our method for reliability estimation is an attractive alternative to those requiring a gold standard and 2) the new method for combining reliabilities is less sensitive to noise in reliability assignments than the similar existing technique. PMID:17990508

  2. Reading for Reliability: Preservice Teachers Evaluate Web Sources about Climate Change

    ERIC Educational Resources Information Center

    Damico, James S.; Panos, Alexandra

    2016-01-01

    This study examined what happened when 65 undergraduate prospective secondary level teachers across content areas evaluated the reliability of four online sources about climate change: an oil company webpage, a news report, and two climate change organizations with competing views on climate change. The students evaluated the sources at three time…

  3. Evaluation of air-displacement plethysmography for body composition assessment in preterm infants

    USDA-ARS?s Scientific Manuscript database

    Adiposity may contribute to the future risk of disease. The aim of this study was to evaluate the accuracy and reliability of an air-displacement plethysmography (ADP) system to estimate percentage fat mass (%FM) in preterm infants and to evaluate interdevice reliability in infants. A total of 70 pr...

  4. Colour evaluation in scars: tristimulus colorimeter, narrow-band simple reflectance meter or subjective evaluation?

    PubMed

    Draaijers, Lieneke J; Tempelman, Fenike R H; Botman, Yvonne A M; Kreis, Robert W; Middelkoop, Esther; van Zuijlen, Paul P M

    2004-03-01

    The evaluation of scar colour is, at present, usually limited to an assessment according to a scar assessment scale. Although useful, these assessment scales only evaluate subjectively the degree of scar colour. In this study, the reliability of the subjective assessment of scar colour by observers is compared to the reliability of the measurements of two objective colour measurement instruments. Four independent observers subjectively assessed the vascularisation and pigmentation of 49 scar areas in 20 patients. The degree of vascularisation and pigmentation was scored according to a scale ranging from '1', when it appeared to be like healthy skin, to '10', which corresponds to the worst imaginable outcome of vascularisation or pigmentation. The observers also scored the pigmentation categories of the scar (hypopigmention, hyperpigmention or mixed pigmentation). Finally, each observer measured the scar areas with a tristimulus colorimeter (Minolta Chromameter) and a narrow-band simple reflectance meter (DermaSpectrometer). A single observer could reliably carry out measurements of the DermaSpectrometer and the Minolta Chromameter for the evaluation of scar colour (r = 0.72). The vascularisation of scars could also be assessed reliably with a single observer (r = 0.76) whereas for a reliable assessment of pigmentation at least three observers were necessary (r > or = 0.77). The agreement between the observers for the pigmentation categories also turned out to be unacceptably low (k = 0.349). This study shows that an overall evaluation of scar colour with the DermaSpectrometer and the Minolta Chromameter is more reliable than the evaluation of scar colour with observers. Of both instruments for measuring scar colour, we prefer, because of its feasibility, the DermaSpectrometer.

  5. Evaluation of Fracture and Osteotomy Union in the Setting of Osteogenesis Imperfecta: Reliability of the Modified Radiographic Union Score for Tibial Fractures (RUST).

    PubMed

    Franzone, Jeanne M; Finkelstein, Mark S; Rogers, Kenneth J; Kruse, Richard W

    2017-09-08

    Evaluation of the union of osteotomies and fractures in patients with osteogenesis imperfecta (OI) is a critical component of patient care. Studies of the OI patient population have so far used varied criteria to evaluate bony union. The radiographic union score for tibial fractures (RUST), which was subsequently revised to the modified RUST, is an objective standardized method of evaluating fracture healing. We sought to evaluate the reliability of the modified RUST in the setting of the tibias of patients with OI. Tibial radiographs of 30 patients with OI fractures, or osteotomies were scored by 3 observers on 2 separate occasions. Each of the 4 cortices was given a score (1=no callus, 2=callus present, 3=bridging callus, and 4=remodeled, fracture not visible) and the modified RUST is the sum of these scores (range, 4 to 16). The interobserver and intraobserver reliabilities were evaluated using intraclass coefficients (ICC) with 95% confidence intervals. The ICC representing the interobserver reliability for the first iteration of scores was 0.926 (0.864 to 0.962) and for the second series was 0.915 (0.845 to 0.957). The ICCs representing the intraobserver reliability for each of the 3 reviewers for the measurements in series 1 and 2 were 0.860 (0.707 to 0.934), 0.994 (0.986 to 0.997), and 0.974 (0.946 to 0.988). The modified RUST has excellent interobserver and intraobserver reliability in the setting of OI despite challenges related to the poor quality of the bone and its dysplastic nature. The application and routine use of the modified RUST in the OI population will help standardize our evaluation of osteotomy and fracture healing. Level III-retrospective study of nonconsecutive patients.

  6. Partnering to Establish and Study Simulation in International Nursing Education.

    PubMed

    Garner, Shelby L; Killingsworth, Erin; Raj, Leena

    The purpose of this article was to describe an international partnership to establish and study simulation in India. A pilot study was performed to determine interrater reliability among faculty new to simulation when evaluating nursing student competency performance. Interrater reliability was below the ideal agreement level. Findings in this study underscore the need to obtain baseline interrater reliability data before integrating competency evaluation into a simulation program.

  7. The reliability of physical examination tests for the clinical assessment of scapular dyskinesis in subjects with shoulder complaints: A systematic review.

    PubMed

    Lange, Toni; Struyf, Filip; Schmitt, Jochen; Lützner, Jörg; Kopkow, Christian

    2017-07-01

    Systematic review. The aim of this systematic review was to summarize and evaluate intra- and interrater reliability research of physical examination tests used for the assessment of scapular dyskinesis. Scapular dyskinesis, defined as alteration of normal scapular kinematics, is described as a non-specific response to different shoulder pathologies. A systematic literature search was conducted in MEDLINE, EMBASE, AMED and PEDro until March 20th, 2015. Methodological quality was assessed with the Quality Appraisal of Reliability Studies (QAREL) by two independent reviewers. The search strategy revealed 3259 articles, of which 15 met the inclusion criteria. These studies evaluated the reliability of 41 test and test variations used for the assessment of scapular dyskinesis. This review identified a lack of high-quality studies evaluating intra- as well as interrater reliability of tests used for the assessment of scapular dyskinesis. In addition, reliability measures differed between included studies hindering proper cross-study comparisons. The effect of manual correction of the scapula on shoulder symptoms was evaluated in only one study, which is striking, since symptom alteration tests are used in routine care to guide further treatment. Thus, there is a strong need for further research in this area. Diagnosis, level 3a. Copyright © 2016. Published by Elsevier Ltd.

  8. Getting the story straight: evaluating the test-retest reliability of a university health history questionnaire.

    PubMed

    Gilkison, C R; Fenton, M V; Lester, J W

    1992-05-01

    This study was designed to establish the reliability of a health history questionnaire used as a screening tool for incoming university students. The authors used a test-retest design, with a test interval of 6 months, on a sample of medical and nursing students. The analysis focused on overall reliability of the questionnaire and reproducibility of specific items, based on question format. Questionnaire items of specific interest were those with dichotomous yes/no response options versus open-ended format questions, those using the words frequently or recently, or those that asked multiple questions. Demographic characteristics of the subjects were considered in the evaluation of reliability. Overall reliability of the questionnaire (93.6%) was above the anticipated level of 90%, and subject sex or program of study did not show any significant differences in reproducibility of responses. Although wording of questions did not affect item reliability, dichotomous format questions demonstrated a higher degree of reliability (96.4%) than the overall reliability of the questionnaire. Recommendations for enhancing the reliability of the questionnaire are based on item analysis and information gathered from interviews with subjects.

  9. Reliability model generator specification

    NASA Technical Reports Server (NTRS)

    Cohen, Gerald C.; Mccann, Catherine

    1990-01-01

    The Reliability Model Generator (RMG), a program which produces reliability models from block diagrams for ASSIST, the interface for the reliability evaluation tool SURE is described. An account is given of motivation for RMG and the implemented algorithms are discussed. The appendices contain the algorithms and two detailed traces of examples.

  10. Methods to approximate reliabilities in single-step genomic evaluation

    USDA-ARS?s Scientific Manuscript database

    Reliability of predictions from single-step genomic BLUP (ssGBLUP) can be calculated by inversion, but that is not feasible for large data sets. Two methods of approximating reliability were developed based on decomposition of a function of reliability into contributions from records, pedigrees, and...

  11. JUPITER PROJECT - JOINT UNIVERSAL PARAMETER IDENTIFICATION AND EVALUATION OF RELIABILITY

    EPA Science Inventory

    The JUPITER (Joint Universal Parameter IdenTification and Evaluation of Reliability) project builds on the technology of two widely used codes for sensitivity analysis, data assessment, calibration, and uncertainty analysis of environmental models: PEST and UCODE.

  12. Approximating genomic reliabilities for national genomic evaluation

    USDA-ARS?s Scientific Manuscript database

    With the introduction of standard methods for approximating effective daughter/data contribution by Interbull in 2001, conventional EDC or reliabilities contributed by daughter phenotypes are directly comparable across countries and used in routine conventional evaluations. In order to make publishe...

  13. The kinematics of upper extremity reaching: a reliability study on people with and without shoulder impingement syndrome

    PubMed Central

    2010-01-01

    Background Tasks chosen to evaluate motor performance should reflect the movement deficits characteristic of the target population and present an appropriate challenge for the patients who would be evaluated. A reaching task that evaluates impairment characteristics of people with shoulder impingement syndrome (SIS) was developed to evaluate the motor performance of this population. The objectives of this study were to characterize the reproducibility of this reaching task in people with and without SIS and to evaluate the impact of the number of trials on reproducibility. Methods Thirty subjects with SIS and twenty healthy subjects participated in the first measurement session to evaluate intrasession reliability. Ten healthy subjects were retested within 2 to 7 days to assess intersession reliability. At each measurement session, upper extremity kinematic patterns were evaluated during a reaching task. Ten trials were recorded. Thereafter, the upper extremity position at the end of reaching and total joint excursion that occurred during reaching were calculated. Intraclass correlation coefficient (ICC) and minimal detectable change (MDC) were used to estimate intra and intersession reliability. Results Intrasession reliability for total joint excursion was good to very good when based on the first two trials (0.770.92). As for end-reach position, intrasession reliability was very good when using either the first two, first five or last five trials (ICC>0.82). Globally, MDC were smaller for the last five trials. Intersession reliability of total joint excursion and position at the end of reaching was good to very good when using the mean of the first two or five trials (0.690.82). For most joints, MDC were smaller when using all ten trials. Conclusions The reaching task proposed to evaluate the upper limb motor performance was found reliable in people with and without SIS. Furthermore, the minimal difference necessary to infer a meaningful change in motor performance was determined, indicating that relatively small changes in task performance can be interpreted as a change in motor performance. PMID:20331889

  14. Validity and Reliability of Spine Rasterstereography in Patients With Adolescent Idiopathic Scoliosis.

    PubMed

    Tabard-Fougère, Anne; Bonnefoy-Mazure, Alice; Hanquinet, Sylviane; Lascombes, Pierre; Armand, Stéphane; Dayer, Romain

    2017-01-15

    Test-retest study. This study aimed to evaluate the validity and reliability of rasterstereography in patients with adolescent idiopathic scoliosis (AIS) with a major curve Cobb angle (CA) between 10° and 40° for frontal, sagittal, and transverse parameters. Previous studies evaluating the validity and reliability of rasterstereography concluded that this technique had good accuracy compared with radiographs and a high intra- and interday reliability in healthy volunteers. To the best of our knowledge, the validity and reliability have not been assessed in AIS patients. Thirty-five adolescents with AIS (male = 13) aged 13.1 ± 2.0 years were included. To evaluate the validity of the scoliosis angle (SA) provided by rasterstereography, a comparison (t test, Pearson correlation) was performed with the CA obtained using 2D EOS® radiography (XR). Three rasterstereographic repeated measurements were independently performed by two operators on the same day (interrater reliability) and again by the first operator 1 week later (intrarater reliability). The variables of interest were the SA, lumbar lordosis, and thoracic kyphosis angle, trunk length, pelvic obliquity, and maximum, root mean square and amplitude of vertebral rotations. The data analyses used intraclass correlation coefficients (ICCs). The CA and SA were strongly correlated (R = 0.70) and were nonsignificantly different (P = 0.60). The intrarater reliability (same day: ICC [1, 1], n = 35; 1 week later: ICC [1, 3], n = 28) and interrater reliability (ICC [3, 3], n = 16) were globally excellent (ICC > 0.75) except for the assessment of pelvic obliquity. This study showed that the rasterstereographic system allows for the evaluation of AIS patients with a good validity compared with XR with an overall excellent intra- and interrater reliability. Based on these results, this automatic, fast, and noninvasive system can be used for monitoring the evolution of AIS in growing patients instead of repetitive radiographs, thereby reducing radiation exposure and decreasing costs. 4.

  15. Survey of critical failure events in on-chip interconnect by fault tree analysis

    NASA Astrophysics Data System (ADS)

    Yokogawa, Shinji; Kunii, Kyousuke

    2018-07-01

    In this paper, a framework based on reliability physics is proposed for adopting fault tree analysis (FTA) to the on-chip interconnect system of a semiconductor. By integrating expert knowledge and experience regarding the possibilities of failure on basic events, critical issues of on-chip interconnect reliability will be evaluated by FTA. In particular, FTA is used to identify the minimal cut sets with high risk priority. Critical events affecting the on-chip interconnect reliability are identified and discussed from the viewpoint of long-term reliability assessment. The moisture impact is evaluated as an external event.

  16. Reliability of Various Measurement Stations for Determining Plantar Fascia Thickness and Echogenicity.

    PubMed

    Bisi-Balogun, Adebisi; Cassel, Michael; Mayer, Frank

    2016-04-13

    This study aimed to determine the relative and absolute reliability of ultrasound (US) measurements of the thickness and echogenicity of the plantar fascia (PF) at different measurement stations along its length using a standardized protocol. Twelve healthy subjects (24 feet) were enrolled. The PF was imaged in the longitudinal plane. Subjects were assessed twice to evaluate the intra-rater reliability. A quantitative evaluation of the thickness and echogenicity of the plantar fascia was performed using Image J, a digital image analysis and viewer software. A sonography evaluation of the thickness and echogenicity of the PF showed a high relative reliability with an Intra class correlation coefficient of ≥0.88 at all measurement stations. However, the measurement stations for both the PF thickness and echogenicity which showed the highest intraclass correlation coefficient (ICCs) did not have the highest absolute reliability. Compared to other measurement stations, measuring the PF thickness at 3 cm distal and the echogenicity at a region of interest 1 cm to 2 cm distal from its insertion at the medial calcaneal tubercle showed the highest absolute reliability with the least systematic bias and random error. Also, the reliability was higher using a mean of three measurements compared to one measurement. To reduce discrepancies in the interpretation of the thickness and echogenicity measurements of the PF, the absolute reliability of the different measurement stations should be considered in clinical practice and research rather than the relative reliability with the ICC.

  17. Reliability of Various Measurement Stations for Determining Plantar Fascia Thickness and Echogenicity

    PubMed Central

    Bisi-Balogun, Adebisi; Cassel, Michael; Mayer, Frank

    2016-01-01

    This study aimed to determine the relative and absolute reliability of ultrasound (US) measurements of the thickness and echogenicity of the plantar fascia (PF) at different measurement stations along its length using a standardized protocol. Twelve healthy subjects (24 feet) were enrolled. The PF was imaged in the longitudinal plane. Subjects were assessed twice to evaluate the intra-rater reliability. A quantitative evaluation of the thickness and echogenicity of the plantar fascia was performed using Image J, a digital image analysis and viewer software. A sonography evaluation of the thickness and echogenicity of the PF showed a high relative reliability with an Intra class correlation coefficient of ≥0.88 at all measurement stations. However, the measurement stations for both the PF thickness and echogenicity which showed the highest intraclass correlation coefficient (ICCs) did not have the highest absolute reliability. Compared to other measurement stations, measuring the PF thickness at 3 cm distal and the echogenicity at a region of interest 1 cm to 2 cm distal from its insertion at the medial calcaneal tubercle showed the highest absolute reliability with the least systematic bias and random error. Also, the reliability was higher using a mean of three measurements compared to one measurement. To reduce discrepancies in the interpretation of the thickness and echogenicity measurements of the PF, the absolute reliability of the different measurement stations should be considered in clinical practice and research rather than the relative reliability with the ICC. PMID:27089369

  18. In vitro model to evaluate reliability and accuracy of a dental shade-matching instrument.

    PubMed

    Kim-Pusateri, Seungyee; Brewer, Jane D; Dunford, Robert G; Wee, Alvin G

    2007-11-01

    There are several electronic shade-matching instruments available for clinical use; unfortunately, there are limited acceptable in vitro models to evaluate their reliability and accuracy. The purpose of this in vitro study was to evaluate the reliability and accuracy of a dental clinical shade-matching instrument. Using the shade-matching instrument (ShadeScan), color measurements were made of 3 commercial shade guides (VITA Classical, VITA 3D-Master, and Chromascop). Shade tabs were selected and placed in the middle of a gingival matrix (Shofu Gummy), with tabs of the same nominal shade from additional shade guides placed on both sides. Measurements were made of the central region of the shade tab inside a black box. For the reliability assessment, each shade tab from each of the 3 shade guide types was measured 10 times. For the accuracy assessment, each shade tab from 10 guides of each of the 3 types evaluated was measured once. Reliability, accuracy, and 95% confidence intervals were calculated for each shade tab. Differences were determined by 1-way ANOVA followed by the Bonferroni multiple comparison procedure. Reliability of ShadeScan was as follows: VITA Classical = 95.0%, VITA 3D-Master = 91.2%, and Chromascop = 76.5%. Accuracy of ShadeScan was as follows: VITA Classical = 65.0%, VITA 3D-Master = 54.2%, Chromascop = 84.5%. This in vitro study showed a varying degree of reliability and accuracy for ShadeScan, depending on the type of shade guide system used.

  19. Evaluation of ceramics for stator application: Gas turbine engine report

    NASA Technical Reports Server (NTRS)

    Trela, W.; Havstad, P. H.

    1978-01-01

    Current ceramic materials, component fabrication processes, and reliability prediction capability for ceramic stators in an automotive gas turbine engine environment are assessed. Simulated engine duty cycle testing of stators conducted at temperatures up to 1093 C is discussed. Materials evaluated are SiC and Si3N4 fabricated from two near-net-shape processes: slip casting and injection molding. Stators for durability cycle evaluation and test specimens for material property characterization, and reliability prediction model prepared to predict stator performance in the simulated engine environment are considered. The status and description of the work performed for the reliability prediction modeling, stator fabrication, material property characterization, and ceramic stator evaluation efforts are reported.

  20. Inter-rater reliability of measures to characterize the tobacco retail environment in Mexico.

    PubMed

    Hall, Marissa G; Kollath-Cattano, Christy; Reynales-Shigematsu, Luz Myriam; Thrasher, James F

    2015-01-01

    To evaluate the inter-rater reliability of a data collection instrument to assess the tobacco retail environment in Mexico, after major marketing regulations were implemented. In 2013, two data collectors independently evaluated 21 stores in two census tracts, through a data collection instrument that assessed the presence of price promotions, whether single cigarettes were sold, the number of visible advertisements, the presence of signage prohibiting the sale of cigarettes to minors, and characteristics of cigarette pack displays. We evaluated the inter-rater reliability of the collected data, through the calculation of metrics such as intraclass correlation coefficient, percent agreement, Cohen's kappa and Krippendorff's alpha. Most measures demonstrated substantial or perfect inter-rater reliability. Our results indicate the potential utility of the data collection instrument for future point-of-sale research.

  1. Development of Reliable and Validated Tools to Evaluate Technical Resuscitation Skills in a Pediatric Simulation Setting: Resuscitation and Emergency Simulation Checklist for Assessment in Pediatrics.

    PubMed

    Faudeux, Camille; Tran, Antoine; Dupont, Audrey; Desmontils, Jonathan; Montaudié, Isabelle; Bréaud, Jean; Braun, Marc; Fournier, Jean-Paul; Bérard, Etienne; Berlengi, Noémie; Schweitzer, Cyril; Haas, Hervé; Caci, Hervé; Gatin, Amélie; Giovannini-Chami, Lisa

    2017-09-01

    To develop a reliable and validated tool to evaluate technical resuscitation skills in a pediatric simulation setting. Four Resuscitation and Emergency Simulation Checklist for Assessment in Pediatrics (RESCAPE) evaluation tools were created, following international guidelines: intraosseous needle insertion, bag mask ventilation, endotracheal intubation, and cardiac massage. We applied a modified Delphi methodology evaluation to binary rating items. Reliability was assessed comparing the ratings of 2 observers (1 in real time and 1 after a video-recorded review). The tools were assessed for content, construct, and criterion validity, and for sensitivity to change. Inter-rater reliability, evaluated with Cohen kappa coefficients, was perfect or near-perfect (>0.8) for 92.5% of items and each Cronbach alpha coefficient was ≥0.91. Principal component analyses showed that all 4 tools were unidimensional. Significant increases in median scores with increasing levels of medical expertise were demonstrated for RESCAPE-intraosseous needle insertion (P = .0002), RESCAPE-bag mask ventilation (P = .0002), RESCAPE-endotracheal intubation (P = .0001), and RESCAPE-cardiac massage (P = .0037). Significantly increased median scores over time were also demonstrated during a simulation-based educational program. RESCAPE tools are reliable and validated tools for the evaluation of technical resuscitation skills in pediatric settings during simulation-based educational programs. They might also be used for medical practice performance evaluations. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Development of An Assessment Test for An Anesthetic Machine.

    PubMed

    Tiviraj, Supinya; Yokubol, Bencharatana; Amornyotin, Somchai

    2016-05-01

    The study is aimed to develop and assess the quality of an evaluation form used to evaluate the nurse anesthetic trainees' skills in undertaking a pre-use check of an anesthetic machine. An evaluation form comprising 25 items was developed, informed by the guidelines published by national anesthesiologist societies and refined to reflect the anesthetic machine used in our institution. The item-checking included the cylinder supplies and medical gas pipelines, vaporizer back bar, ventilator anesthetic breathing system, scavenging system and emergency back-up equipment. The authors sought the opinions of five experienced anesthetic trainers to judge the validity of the content. The authors measured its inter-rater reliability when used by two achievement scores evaluating the performance of 36 nurse anesthetic trainees undertaking 15-minute anesthetic machine checks and test-retest the reliability correlation scores between the two performances in the seven days interval. The five experienced anesthesiologists agreed that the evaluation form accurately reflected the objectives of anesthetic machine checking, equating to an index of congruency of 1.00. The inter-rater reliability of the independent assessors scoring was 0.977 (p = 0.01) and the test-retest reliability was 0.883 (p = 0.01). An evaluation form proved to be a reliable and effective tool for assessing the anesthetic nurse trainees' checking of an anesthetic machine before the use. This evaluation form was brief clear and practical to use, and should help to improve anesthetic nurse education and the patient safety.

  3. Validation of the Dementia Care Assessment Packet-Instrumental Activities of Daily Living

    PubMed Central

    Lee, Seok Bum; Park, Jeong Ran; Yoo, Jeong-Hwa; Park, Joon Hyuk; Lee, Jung Jae; Yoon, Jong Chul; Jhoo, Jin Hyeong; Lee, Dong Young; Woo, Jong Inn; Han, Ji Won; Huh, Yoonseok; Kim, Tae Hui

    2013-01-01

    Objective We aimed to evaluate the psychometric properties of the IADL measure included in the Dementia Care Assessment Packet (DCAP-IADL) in dementia patients. Methods The study involved 112 dementia patients and 546 controls. The DCAP-IADL was scored in two ways: observed score (OS) and predicted score (PS). The reliability of the DCAP-IADL was evaluated by testing its internal consistency, inter-rater reliability and test-retest reliability. Discriminant validity was evaluated by comparing the mean OS and PS between dementia patients and controls by ANCOVA. Pearson or Spearman correlation analysis was performed with other instruments to assess concurrent validity. Receiver operating characteristics curve analysis was performed to examine diagnostic accuracy. Results Chronbach's α coefficients of the DCAP-IADL were above 0.7. The values in dementia patients were much higher (OS=0.917, PS=0.927), indicating excellent degrees of internal consistency. Inter-rater reliabilities and test-retest reliabilities were statistically significant (p<0.05). PS exhibited higher reliabilities than OS. The mean OS and PS of dementia patients were significantly higher than those of the non-demented group after controlling for age, sex and education level. The DCAP-IADL was significantly correlated with other IADL instruments and MMSE-KC (p<0.001). Areas under the curves of the DCAP-IADL were above 0.9. Conclusion The DCAP-IADL is a reliable and valid instrument for evaluating instrumental ability of daily living for the elderly, and may also be useful for screening dementia. Moreover, administering PS may enable the DCAP-IADL to overcome the differences in gender, culture and life style that hinders accurate evaluation of the elderly in previous IADL instruments. PMID:24302946

  4. The analysis of reliability and validity of the IT-MAIS, MAIS and MUSS.

    PubMed

    Zhong, Yan; Xu, Tianqiu; Dong, Ruijuan; Lyu, Jing; Liu, Bo; Chen, Xueqing

    2017-05-01

    The aim of this study was to investigate the reliability and validity of the Infant-toddler Meaningful Auditory Integration Scale (IT-MAIS), Meaningful Auditory Integration Scale (MAIS), and Meaningful Use of Speech Scale (MUSS). IT-MAIS, MAIS and MUSS were divided into 3 sub dimensions. 300 children with cochlear implants (CI) were included in the investigation. To assess test-retest reliability of these questionnaires, 30 children were selected randomly to be evaluated at a two-week interval indicated that there were no significant changes between test and retest. Furthermore random test analysis by different evaluators was also administered to 30 users. Reliability test: Test-retest reliability of the three scales was proved to be satisfactory. All domains had correlation coefficients that exceeded 0.750(P < 0.01). The Cronbach's α of the three scales and their three domains were greater than 0.700. Reliability between evaluators of the three scales were considered to be satisfactory. All domains had correlation coefficients that exceeded 0.750(P < 0.01). Validity test: The evaluation of content validity by expert review showed the questionnaire had good content validity; The correlation coefficients between the overall scores of the three scales and their three domains were 0.699-0.978(P < 0.01). There were correlations among the three sub-domains but the strength of the correlations was relatively low. There was certain construct validity. IT-MAIS, MAIS, MUSS scales have good reliability and validity, and can be used to measure the outcome for children with cochlear implants hearing and speech evaluation. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Comparative ex vivo evaluation of two electronic percussive testing devices measuring the stability of dental implants.

    PubMed

    Geckili, Onur; Bilhan, Hakan; Cilingir, Altug; Bilmenoglu, Caglar; Ates, Gokcen; Urgun, Aliye Ceren; Bural, Canan

    2014-12-01

    A comparative ex vivo study was performed to determine electronic percussive test values (PTVs) measured by cabled and wireless electronic percussive testing (EPT) devices and to evaluate the intra- and interobserver reliability of the wireless EPT device. Forty implants were inserted into the vertebrae and forty into the pelvis of a steer, a safe distance apart. The implants were all 4.3 mm wide and 13 mm long, from the same manufacturer. PTV of each implant was measured by four different examiners, using both EPT devices, and compared. Additionally, the intra- and interobserver reliability of the wireless EPT device was evaluated. Statistically significant differences (P <0.05) were observed between PTVs made by the two EPT devices. PTVs measured by the wireless EPT device were significantly higher than the cabled EPT device (P <0.05), indicating lower implant stability. The intraobserver reliability of the wireless EPT device was evaluated as excellent for the measurements in type II bone and good-to-excellent in type IV bone; interobserver reliability was evaluated as fair-to-good in both bone types. The wireless EPT device gives PTVs higher than the cabled EPT device, indicating lower implant stability, and its inter- and intraobserver reliability is good and acceptable.

  6. Evaluating "The Safe Living Guide": A Home Hazard Checklist for Seniors

    ERIC Educational Resources Information Center

    Sorcinelli, Andrea; Shaw, Lynn; Freeman, Andrew; Cooper, Kim

    2007-01-01

    Purpose: The purpose of this study was to evaluate the utility and reliability of a home hazard checklist published in Health Canada, "The Safe Living Guide: A Guide to Home Safety for Seniors" (2003). Methods: 76 community-dwelling seniors evaluated the guide, and inter-rater reliability was determined through comparison of ratings of…

  7. Reliability and Validity of a Physical Capacity Evaluation Used to Assess Individuals with Intellectual Disabilities and Mental Illness

    ERIC Educational Resources Information Center

    Jang, Yuh; Chang, Tzyh-Chyang; Lin, Keh-Chung

    2009-01-01

    Physical capacity evaluations (PCEs) are important and frequently offered services in work practice. This study investigates the reliability and validity of the National Taiwan University Hospital Physical Capacity Evaluation (NTUH PCE) on a sample of 149 participants consisted of three groups: 45 intellectual disability (ID), 56 mental illness…

  8. A Study of Developing an Attitude Scale towards Authentic Learning Environments and Evaluation

    ERIC Educational Resources Information Center

    Çetinkaya, Murat

    2018-01-01

    The aim of the research is to improve a valid and reliable attributing scale which identifies authentic learning environments and evaluation attributes of the science teacher candidates. The study has been designed on the base of validity and reliability of the scale developed to evaluate the authentic learning environments. The research group is…

  9. Evaluating the Level of Degree Programmes in Higher Education: The Case of Nursing

    ERIC Educational Resources Information Center

    Rexwinkel, Trudy; Haenen, Jacques; Pilot, Albert

    2013-01-01

    The European Quality Assurance system demands that the degree programme level is represented in terms of quantitative outcomes to be valid and reliable. To meet this need the Educational Level Evaluator (ELE) was devised. This conceptually designed procedure with instrumentation aiming to evaluate the level of a degree validly and reliably still…

  10. Computer Usage and the Validity of Self-Assessed Computer Competence among First-Year Business Students

    ERIC Educational Resources Information Center

    Ballantine, Joan A.; McCourt Larres, Patricia; Oyelere, Peter

    2007-01-01

    This study evaluates the reliability of self-assessment as a measure of computer competence. This evaluation is carried out in response to recent research which has employed self-reported ratings as the sole indicator of students' computer competence. To evaluate the reliability of self-assessed computer competence, the scores achieved by students…

  11. Reliability model generator

    NASA Technical Reports Server (NTRS)

    Cohen, Gerald C. (Inventor); McMann, Catherine M. (Inventor)

    1991-01-01

    An improved method and system for automatically generating reliability models for use with a reliability evaluation tool is described. The reliability model generator of the present invention includes means for storing a plurality of low level reliability models which represent the reliability characteristics for low level system components. In addition, the present invention includes means for defining the interconnection of the low level reliability models via a system architecture description. In accordance with the principles of the present invention, a reliability model for the entire system is automatically generated by aggregating the low level reliability models based on the system architecture description.

  12. [Validation of the Polish version of The Authentic Leadership Questionnaire for the of evaluation purpose of nursing management staff in national hospital wards].

    PubMed

    Sierpińska, Lidia

    2013-09-01

    The Authentic Leadership Questionnaire (ALQ) is a standardized research instrument for the evaluation of individual elements of leader's conduct which contribute to the authentic leadership. The application of this questionnaire in Polish conditions required to carry out the validation process. The aim of the study was to evaluate of validity and reliability of the Polish version of the American research instrument for the needs of evaluation of authenticity of leadership of the nursing management in Polish hospitals. The study covered 286 nurses (143 head nurses and 143 of their subordinates) employed in 45 hospitals in Poland. Theoretical validity of the instrument was evaluated using Fisher's transformation (r-Person correlation coefficient), while the criterion validity of the ALQ was evaluated using rho-Spearman correlation coefficient and the BOHIPSZO questionnaire. The reliability of the ALQ was assessed by means of the Cronbach-alpha coefficient. The ALQ questionnaire applied for the evaluation of authenticity of leadership of the nursing management in Polish hospital wards shows an acceptable theoretical and criterion validity and reliability (Cronbach-alpha coefficient 0.80). The Polish version of the ALQ is valid and reliable, and may be applied in studies concerning the evaluation of authenticity of leadership of the nursing management in Polish hospital wards.

  13. A motor speech assessment for children with severe speech disorders: reliability and validity evidence.

    PubMed

    Strand, Edythe A; McCauley, Rebecca J; Weigand, Stephen D; Stoeckel, Ruth E; Baas, Becky S

    2013-04-01

    In this article, the authors report reliability and validity evidence for the Dynamic Evaluation of Motor Speech Skill (DEMSS), a new test that uses dynamic assessment to aid in the differential diagnosis of childhood apraxia of speech (CAS). Participants were 81 children between 36 and 79 months of age who were referred to the Mayo Clinic for diagnosis of speech sound disorders. Children were given the DEMSS and a standard speech and language test battery as part of routine evaluations. Subsequently, intrajudge, interjudge, and test-retest reliability were evaluated for a subset of participants. Construct validity was explored for all 81 participants through the use of agglomerative cluster analysis, sensitivity measures, and likelihood ratios. The mean percentage of agreement for 171 judgments was 89% for test-retest reliability, 89% for intrajudge reliability, and 91% for interjudge reliability. Agglomerative hierarchical cluster analysis showed that total DEMSS scores largely differentiated clusters of children with CAS vs. mild CAS vs. other speech disorders. Positive and negative likelihood ratios and measures of sensitivity and specificity suggested that the DEMSS does not overdiagnose CAS but sometimes fails to identify children with CAS. The value of the DEMSS in differential diagnosis of severe speech impairments was supported on the basis of evidence of reliability and validity.

  14. Summative assessment of undergraduates' communication competence in challenging doctor-patient encounters. Evaluation of the Düsseldorf CoMeD-OSCE.

    PubMed

    Mortsiefer, Achim; Immecke, Janine; Rotthoff, Thomas; Karger, André; Schmelzer, Regine; Raski, Bianca; Schmitten, Jürgen In der; Altiner, Attila; Pentzek, Michael

    2014-06-01

    To evaluate the summative assessment (OSCE) of a communication training programme for dealing with challenging doctor-patient encounters in the 4th study year. Our OSCE consists of 4 stations (breaking bad news, guilt and shame, aggressive patients, shared decision making), using a 4-item global rating (GR) instrument. We calculated reliability coefficients for different levels, discriminability of single items and interrater reliability. Validity was estimated by gender differences and accordance between GR and a checklist. In a pooled sample of 456 students in 3 OSCEs over 3 terms, total reliability was α=0.64, reliability coefficients for single stations were >0.80, and discriminability in 3 of 4 stations was within the range of 0.4-0.7. Except for one station, interrater reliability was moderate to strong. Reliability on item level was poor and pointed to some problems with the use of the GR. The application of the GR on regular undergraduate medical education shows moderate reliability in need of improvement and some traits of validity. Ongoing development and evaluation is needed with particular regard to the training of the examiners. Our CoMeD-OSCE proved suitable for the summative assessment of communication skills in challenging doctor-patient encounters. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  15. Toward a Common Language for Measuring Patient Mobility in the Hospital: Reliability and Construct Validity of Interprofessional Mobility Measures.

    PubMed

    Hoyer, Erik H; Young, Daniel L; Klein, Lisa M; Kreif, Julie; Shumock, Kara; Hiser, Stephanie; Friedman, Michael; Lavezza, Annette; Jette, Alan; Chan, Kitty S; Needham, Dale M

    2018-02-01

    The lack of common language among interprofessional inpatient clinical teams is an important barrier to achieving inpatient mobilization. In The Johns Hopkins Hospital, the Activity Measure for Post-Acute Care (AM-PAC) Inpatient Mobility Short Form (IMSF), also called "6-Clicks," and the Johns Hopkins Highest Level of Mobility (JH-HLM) are part of routine clinical practice. The measurement characteristics of these tools when used by both nurses and physical therapists for interprofessional communication or assessment are unknown. The purposes of this study were to evaluate the reliability and minimal detectable change of AM-PAC IMSF and JH-HLM when completed by nurses and physical therapists and to evaluate the construct validity of both measures when used by nurses. A prospective evaluation of a convenience sample was used. The test-retest reliability and the interrater reliability of AM-PAC IMSF and JH-HLM for inpatients in the neuroscience department (n = 118) of an academic medical center were evaluated. Each participant was independently scored twice by a team of 2 nurses and 1 physical therapist; a total of 4 physical therapists and 8 nurses participated in reliability testing. In a separate inpatient study protocol (n = 69), construct validity was evaluated via an assessment of convergent validity with other measures of function (grip strength, Katz Activities of Daily Living Scale, 2-minute walk test, 5-times sit-to-stand test) used by 5 nurses. The test-retest reliability values (intraclass correlation coefficients) for physical therapists and nurses were 0.91 and 0.97, respectively, for AM-PAC IMSF and 0.94 and 0.95, respectively, for JH-HLM. The interrater reliability values (intraclass correlation coefficients) between physical therapists and nurses were 0.96 for AM-PAC IMSF and 0.99 for JH-HLM. Construct validity (Spearman correlations) ranged from 0.25 between JH-HLM and right-hand grip strength to 0.80 between AM-PAC IMSF and the Katz Activities of Daily Living Scale. The results were obtained from inpatients in the neuroscience department of a single hospital. The AM-PAC IMSF and JH-HLM had excellent interrater reliability and test-retest reliability for both physical therapists and nurses. The evaluation of convergent validity suggested that AM-PAC IMSF and JH-HLM measured constructs of patient mobility and physical functioning. © 2017 American Physical Therapy Association

  16. Health measurement using the ICF: Test-retest reliability study of ICF codes and qualifiers in geriatric care

    PubMed Central

    Okochi, Jiro; Utsunomiya, Sakiko; Takahashi, Tai

    2005-01-01

    Background The International Classification of Functioning, Disability and Health (ICF) was published by the World Health Organization (WHO) to standardize descriptions of health and disability. Little is known about the reliability and clinical relevance of measurements using the ICF and its qualifiers. This study examines the test-retest reliability of ICF codes, and the rate of immeasurability in long-term care settings of the elderly to evaluate the clinical applicability of the ICF and its qualifiers, and the ICF checklist. Methods Reliability of 85 body function (BF) items and 152 activity and participation (AP) items of the ICF was studied using a test-retest procedure with a sample of 742 elderly persons from 59 institutional and at home care service centers. Test-retest reliability was estimated using the weighted kappa statistic. The clinical relevance of the ICF was estimated by calculating immeasurability rate. The effect of the measurement settings and evaluators' experience was analyzed by stratification of these variables. The properties of each item were evaluated using both the kappa statistic and immeasurability rate to assess the clinical applicability of WHO's ICF checklist in the elderly care setting. Results The median of the weighted kappa statistics of 85 BF and 152 AP items were 0.46 and 0.55 respectively. The reproducibility statistics improved when the measurements were performed by experienced evaluators. Some chapters such as genitourinary and reproductive functions in the BF domain and major life area in the AP domain contained more items with lower test-retest reliability measures and rated as immeasurable than in the other chapters. Some items in the ICF checklist were rated as unreliable and immeasurable. Conclusion The reliability of the ICF codes when measured with the current ICF qualifiers is relatively low. The result in increase in reliability according to evaluators' experience suggests proper education will have positive effects to raise the reliability. The ICF checklist contains some items that are difficult to be applied in the geriatric care settings. The improvements should be achieved by selecting the most relevant items for each measurement and by developing appropriate qualifiers for each code according to the interest of the users. PMID:16050960

  17. Reliability of the Client-Centeredness of Goal Setting (C-COGS) Scale in Acquired Brain Injury Rehabilitation.

    PubMed

    Doig, Emmah; Prescott, Sarah; Fleming, Jennifer; Cornwell, Petrea; Kuipers, Pim

    2016-01-01

    To examine the internal reliability and test-retest reliability of the Client-Centeredness of Goal Setting (C-COGS) scale. The C-COGS scale was administered to 42 participants with acquired brain injury after completion of multidisciplinary goal planning. Internal reliability of scale items was examined using item-partial total correlations and Cronbach's α coefficient. The scale was readministered within a 1-mo period to a subsample of 12 participants to examine test-retest reliability by calculating exact and close percentage agreement for each item. After examination of item-partial total correlations, test items were revised. The revised items demonstrated stronger internal consistency than the original items. Preliminary evaluation of test-retest reliability was fair, with an average exact percent agreement across all test items of 67%. Findings support the preliminary reliability of the C-COGS scale as a tool to evaluate and promote client-centered goal planning in brain injury rehabilitation. Copyright © 2016 by the American Occupational Therapy Association, Inc.

  18. Reliability and Validity of the Chinese (Mandarin) Tinnitus Handicap Inventory

    PubMed Central

    Meng, Zhaoli; Zheng, Yun; Wang, Kai; Kong, Xiudan; Tao, Yong; Xu, Ke; Liu, Guanjian

    2012-01-01

    Objectives The Tinnitus Handicap Inventory (THI) is a commonly used self-reporting tinnitus questionnaire. We undertook this study to determine the reliability and validity of the Chinese-Mandarin version of the Tinnitus Handicap Inventory (THI-CM) for measuring tinnitus-related handicaps. Methods We tested the test-retest reliability, internal reliability, and construct validity of the THI-CM. Two-hundred patients seeking treatment for primary or secondary tinnitus in Southwest China were asked to complete THI-CM prior to clinical evaluation. Patients were evaluated by a clinician using standard methods, and 40 patients were asked to complete THI-CM a second time 14±3 days after the initial interview. Results The test-retest reliability of THI-CM was high (Pearson correlation, 0.98), as was the internal reliability (Cronbach's α, 0.93). Factor analysis indicated that THI-CM has a unifactorial structure. Conclusion The THI-CM version is reliable. The total score in THI-CM can be used to measure tinnitus-related handicaps in Mandarin-speaking populations. PMID:22468196

  19. Reliability apportionment approach for spacecraft solar array using fuzzy reasoning Petri net and fuzzy comprehensive evaluation

    NASA Astrophysics Data System (ADS)

    Wu, Jianing; Yan, Shaoze; Xie, Liyang; Gao, Peng

    2012-07-01

    The reliability apportionment of spacecraft solar array is of significant importance for spacecraft designers in the early stage of design. However, it is difficult to use the existing methods to resolve reliability apportionment problem because of the data insufficiency and the uncertainty of the relations among the components in the mechanical system. This paper proposes a new method which combines the fuzzy comprehensive evaluation with fuzzy reasoning Petri net (FRPN) to accomplish the reliability apportionment of the solar array. The proposed method extends the previous fuzzy methods and focuses on the characteristics of the subsystems and the intrinsic associations among the components. The analysis results show that the synchronization mechanism may obtain the highest reliability value and the solar panels and hinges may get the lowest reliability before design and manufacturing. Our developed method is of practical significance for the reliability apportionment of solar array where the design information has not been clearly identified, particularly in early stage of design.

  20. CARES/LIFE Ceramics Analysis and Reliability Evaluation of Structures Life Prediction Program

    NASA Technical Reports Server (NTRS)

    Nemeth, Noel N.; Powers, Lynn M.; Janosik, Lesley A.; Gyekenyesi, John P.

    2003-01-01

    This manual describes the Ceramics Analysis and Reliability Evaluation of Structures Life Prediction (CARES/LIFE) computer program. The program calculates the time-dependent reliability of monolithic ceramic components subjected to thermomechanical and/or proof test loading. CARES/LIFE is an extension of the CARES (Ceramic Analysis and Reliability Evaluation of Structures) computer program. The program uses results from MSC/NASTRAN, ABAQUS, and ANSYS finite element analysis programs to evaluate component reliability due to inherent surface and/or volume type flaws. CARES/LIFE accounts for the phenomenon of subcritical crack growth (SCG) by utilizing the power law, Paris law, or Walker law. The two-parameter Weibull cumulative distribution function is used to characterize the variation in component strength. The effects of multiaxial stresses are modeled by using either the principle of independent action (PIA), the Weibull normal stress averaging method (NSA), or the Batdorf theory. Inert strength and fatigue parameters are estimated from rupture strength data of naturally flawed specimens loaded in static, dynamic, or cyclic fatigue. The probabilistic time-dependent theories used in CARES/LIFE, along with the input and output for CARES/LIFE, are described. Example problems to demonstrate various features of the program are also included.

  1. Ethical Implications of Validity-vs.-Reliability Trade-Offs in Educational Research

    ERIC Educational Resources Information Center

    Fendler, Lynn

    2016-01-01

    In educational research that calls itself empirical, the relationship between validity and reliability is that of trade-off: the stronger the bases for validity, the weaker the bases for reliability (and vice versa). Validity and reliability are widely regarded as basic criteria for evaluating research; however, there are ethical implications of…

  2. Interpretive Reliability of Six Computer-Based Test Interpretation Programs for the Minnesota Multiphasic Personality Inventory-2.

    PubMed

    Deskovitz, Mark A; Weed, Nathan C; McLaughlan, Joseph K; Williams, John E

    2016-04-01

    The reliability of six Minnesota Multiphasic Personality Inventory-Second edition (MMPI-2) computer-based test interpretation (CBTI) programs was evaluated across a set of 20 commonly appearing MMPI-2 profile codetypes in clinical settings. Evaluation of CBTI reliability comprised examination of (a) interrater reliability, the degree to which raters arrive at similar inferences based on the same CBTI profile and (b) interprogram reliability, the level of agreement across different CBTI systems. Profile inferences drawn by four raters were operationalized using q-sort methodology. Results revealed no significant differences overall with regard to interrater and interprogram reliability. Some specific CBTI/profile combinations (e.g., the CBTI by Automated Assessment Associates on a within normal limits profile) and specific profiles (e.g., the 4/9 profile displayed greater interprogram reliability than the 2/4 profile) were interpreted with variable consensus (α range = .21-.95). In practice, users should consider that certain MMPI-2 profiles are interpreted more or less consensually and that some CBTIs show variable reliability depending on the profile. © The Author(s) 2015.

  3. Bearing Procurement Analysis Method by Total Cost of Ownership Analysis and Reliability Prediction

    NASA Astrophysics Data System (ADS)

    Trusaji, Wildan; Akbar, Muhammad; Sukoyo; Irianto, Dradjad

    2018-03-01

    In making bearing procurement analysis, price and its reliability must be considered as decision criteria, since price determines the direct cost as acquisition cost and reliability of bearing determine the indirect cost such as maintenance cost. Despite the indirect cost is hard to identify and measured, it has high contribution to overall cost that will be incurred. So, the indirect cost of reliability must be considered when making bearing procurement analysis. This paper tries to explain bearing evaluation method with the total cost of ownership analysis to consider price and maintenance cost as decision criteria. Furthermore, since there is a lack of failure data when bearing evaluation phase is conducted, reliability prediction method is used to predict bearing reliability from its dynamic load rating parameter. With this method, bearing with a higher price but has higher reliability is preferable for long-term planning. But for short-term planning the cheaper one but has lower reliability is preferable. This contextuality can give rise to conflict between stakeholders. Thus, the planning horizon needs to be agreed by all stakeholder before making a procurement decision.

  4. Development and reliability of a Turkish version of the Short Form-Joint Protection Behavior Assessment (JPBA-S).

    PubMed

    Tonga, Eda; Atasavun Uysal, Songul; Karayazgan, Sedef; Hayran, Mutlu; Düger, Tülin

    2016-01-01

    Clinical measurement. To adapt the original JPBA-S to a Turkish version (TUR-JPBA-S) and to investigate its reliability in assessing patients with rheumatoid arthritis (RA). Twenty-two participants with RA and 21 healthy people were videotaped while performing tasks listed in the TUR-JPBA-S. Two raters scored the video recordings for to evaluate inter-rater reliability. One rater re-analyzed the recordings at a different time point for intra-rater reliability. Participants with RA were asked to perform the same tasks after three to four weeks which was also recorded to evaluate test-retest reliability. Internal consistency (Cronbach's α value) was found to be high (0.89) for participants with RA. Our results demonstrate excellent intra-rater (ICC: 0.99, SEM 1.2) inter-rater (ICC: 0.99, SEM 1.7) reliability, apart from excellent test-retest reliability (ICC: 0.96). The TUR-JPBA-S is a valid and reliable instrument for assessing JP behavior in patients with RA in Turkey. Level 2. Copyright © 2016 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  5. Updated Reliability Evaluation of V730 Transmission

    DOT National Transportation Integrated Search

    1983-11-01

    This report culminates a two-year review of factors concerning the reliability of the Detroit Diesel Allison V730 automatic three-speed transmission for urban transit buses. This report is a continuing examination of the transmission's reliability. M...

  6. Internal Consistency, Retest Reliability, and their Implications For Personality Scale Validity

    PubMed Central

    McCrae, Robert R.; Kurtz, John E.; Yamagata, Shinji; Terracciano, Antonio

    2010-01-01

    We examined data (N = 34,108) on the differential reliability and validity of facet scales from the NEO Inventories. We evaluated the extent to which (a) psychometric properties of facet scales are generalizable across ages, cultures, and methods of measurement; and (b) validity criteria are associated with different forms of reliability. Composite estimates of facet scale stability, heritability, and cross-observer validity were broadly generalizable. Two estimates of retest reliability were independent predictors of the three validity criteria; none of three estimates of internal consistency was. Available evidence suggests the same pattern of results for other personality inventories. Internal consistency of scales can be useful as a check on data quality, but appears to be of limited utility for evaluating the potential validity of developed scales, and it should not be used as a substitute for retest reliability. Further research on the nature and determinants of retest reliability is needed. PMID:20435807

  7. Status of the Ford program to evaluate ceramics for stator applications in automotive gas turbine engines

    NASA Technical Reports Server (NTRS)

    Trela, W.

    1980-01-01

    The paper reviews the progress of the major technical tasks of the DOE/NASA/Ford program Evaluation of Ceramics for Stator Applications in Automotive Gas Turbine Engines: reliability prediction, stator fabrication, material characterization, and stator evaluation. A fast fracture reliability model was prepared for a one-piece ceramic stator. Periodic inspection results are presented.

  8. The Turkish Version of Web-Based Learning Platform Evaluation Scale: Reliability and Validity Study

    ERIC Educational Resources Information Center

    Dag, Funda

    2016-01-01

    The purpose of this study is to determine the language equivalence and the validity and reliability of the Turkish version of the "Web-Based Learning Platform Evaluation Scale" ("Web Tabanli Ögrenme Ortami Degerlendirme Ölçegi" [WTÖODÖ]) used in the selection and evaluation of web-based learning environments. Within this scope,…

  9. BUILDING MODEL ANALYSIS APPLICATIONS WITH THE JOINT UNIVERSAL PARAMETER IDENTIFICATION AND EVALUATION OF RELIABILITY (JUPITER) API

    EPA Science Inventory

    The open-source, public domain JUPITER (Joint Universal Parameter IdenTification and Evaluation of Reliability) API (Application Programming Interface) provides conventions and Fortran-90 modules to develop applications (computer programs) for analyzing process models. The input ...

  10. Reliability, Validity, and Factor Structure of the Current Assessment Practice Evaluation-Revised (CAPER) in a National Sample.

    PubMed

    Lyon, Aaron R; Pullmann, Michael D; Dorsey, Shannon; Martin, Prerna; Grigore, Alexandra A; Becker, Emily M; Jensen-Doss, Amanda

    2018-05-11

    Measurement-based care (MBC) is an increasingly popular, evidence-based practice, but there are no tools with established psychometrics to evaluate clinician use of MBC practices in mental health service delivery. The current study evaluated the reliability, validity, and factor structure of scores generated from a brief, standardized tool to measure MBC practices, the Current Assessment Practice Evaluation-Revised (CAPER). Survey data from a national sample of 479 mental health clinicians were used to conduct exploratory and confirmatory factor analyses, as well as reliability and validity analyses (e.g., relationships between CAPER subscales and clinician MBC attitudes). Analyses revealed competing two- and three-factor models. Regardless of the model used, scores from CAPER subscales demonstrated good reliability and convergent and divergent validity with MBC attitudes in the expected directions. The CAPER appears to be a psychometrically sound tool for assessing clinician MBC practices. Future directions for development and application of the tool are discussed.

  11. Integrated Evaluation of Reliability and Power Consumption of Wireless Sensor Networks

    PubMed Central

    Dâmaso, Antônio; Maciel, Paulo

    2017-01-01

    Power consumption is a primary interest in Wireless Sensor Networks (WSNs), and a large number of strategies have been proposed to evaluate it. However, those approaches usually neither consider reliability issues nor the power consumption of applications executing in the network. A central concern is the lack of consolidated solutions that enable us to evaluate the power consumption of applications and the network stack also considering their reliabilities. To solve this problem, we introduce a fully automatic solution to design power consumption aware WSN applications and communication protocols. The solution presented in this paper comprises a methodology to evaluate the power consumption based on the integration of formal models, a set of power consumption and reliability models, a sensitivity analysis strategy to select WSN configurations and a toolbox named EDEN to fully support the proposed methodology. This solution allows accurately estimating the power consumption of WSN applications and the network stack in an automated way. PMID:29113078

  12. [Development and reliability evaluation of an instrument to measure health-related quality of life in independent elderly].

    PubMed

    Lima, Maria José Barbosa de; Portela, Margareth Crisóstomo

    2010-08-01

    This study presents an instrument, the health-related quality of life (HRQOL) profile for independent elderly, to measure the health-related quality of life of the functionally independent elderly assisted in the outpatient setting, based on the adaptation of four validated scales: Short-Form Health Survey (SF-36), Duke-UNC Health Profile (DUHP), Sickness Impact Profile (SIP), and Nottingham Health Profile (NHP). The study also evaluates the instrument's reliability based on its use by two different observers with a 15-day interval. The instrument includes five dimensions (health perception, symptoms, physical function, psychological function, and social function) and 45 items. Reliability evaluation of the QUASI instrument was based on interviews with 142 elderly outpatients in the city of Rio de Janeiro, Brazil. Prevalence-adjusted kappa statistic was used to assess all 45 items. Correlation was also calculated between overall scores and scores on individual dimensions. In the reliability evaluation, 39 of the 45 items showed prevalence-adjusted kappa greater than 0.60.

  13. The quality of orthodontic practice websites.

    PubMed

    Parekh, J; Gill, D S

    2014-05-01

    To evaluate orthodontic practice websites for the reliability of information presented, accessibility, usability for patients and compliance to General Dental Council (GDC) regulations on ethical advertising. World Wide Web. The term 'orthodontic practice' was entered into three separate search engines. The 30 websites from the UK were selected and graded according to the LIDA tool (a validated method of evaluating healthcare websites) for accessibility, usability of the website and reliability of information on orthodontic treatment. The websites were then evaluated against the GDC's Principles for ethical advertising in nine different criteria. On average, each website fulfilled six out of nine points of the GDC's criteria, with inclusion of a complaints policy being the most poorly fulfilled criteria. The mean LIDA score (a combination of usability, reliability and accessibility) was 102/144 (standard deviation 8.38). The websites scored most poorly on reliability (average 43% SD 11.7), with no single website reporting a clear, reliable method of content production. Average accessibility was 81% and usability 73%. In general, websites did not comply with GDC guidelines on ethical advertising. Furthermore, practitioners should consider reporting their method of information production, particularly when making claims about efficiency and speed of treatment in order to improve reliability.

  14. Reliability of the Cardiff Test of basic life support and automated external defibrillation version 3.1.

    PubMed

    Whitfield, Richard H; Newcombe, Robert G; Woollard, Malcolm

    2003-12-01

    The introduction of the European Resuscitation Guidelines (2000) for cardiopulmonary resuscitation (CPR) and automated external defibrillation (AED) prompted the development of an up-to-date and reliable method of assessing the quality of performance of CPR in combination with the use of an AED. The Cardiff Test of basic life support (BLS) and AED version 3.1 was developed to meet this need and uses standardised checklists to retrospectively evaluate performance from analyses of video recordings and data drawn from a laptop computer attached to a training manikin. This paper reports the inter- and intra-observer reliability of this test. Data used to assess reliability were obtained from an investigation of CPR and AED skill acquisition in a lay responder AED training programme. Six observers were recruited to evaluate performance in 33 data sets, repeating their evaluation after a minimum interval of 3 weeks. More than 70% of the 42 variables considered in this study had a kappa score of 0.70 or above for inter-observer reliability or were drawn from computer data and therefore not subject to evaluator variability. 85% of the 42 variables had kappa scores for intra-observer reliability of 0.70 or above or were drawn from computer data. The standard deviations for inter- and intra-observer measures of time to first shock were 11.6 and 7.7 s, respectively. The inter- and intra-observer reliability for the majority of the variables in the Cardiff Test of BLS and AED version 3.1 is satisfactory. However, reliability is less acceptable with respect to shaking when checking for responsiveness, initial check/clearing of the airway, checks for signs of circulation, time to first shock and performance of interventions in the correct sequence. Further research is required to determine if modifications to the method of assessing these variables can increase reliability.

  15. Inter-rater reliability of a food store checklist to assess availability of healthier alternatives to the energy-dense snacks and beverages commonly consumed by children.

    PubMed

    Izumi, Betty T; Findholt, Nancy E; Pickus, Hayley A; Nguyen, Thuan; Cuneo, Monica K

    2014-06-01

    Food stores have gained attention as potential intervention targets for improving children's eating habits. There is a need for valid and reliable instruments to evaluate changes in food store snack and beverage availability secondary to intervention. The aim of this study was to develop a valid, reliable, and resource-efficient instrument to evaluate the healthfulness of food store environments faced by children. The SNACZ food store checklist was developed to assess availability of healthier alternatives to the energy-dense snacks and beverages commonly consumed by children. After pretesting, two trained observers independently assessed the availability of 48 snack and beverage items in 50 food stores located near elementary and middle schools in Portland, Oregon, over a 2-week period in summer 2012. Inter-rater reliability was calculated using the kappa statistic. Overall, the instrument had mostly high inter-rater reliability. Seventy-three percent of items assessed had almost perfect or substantial reliability. Two items had moderate reliability (0.41-0.60), and no items had a reliability score less than 0.41. Eleven items occurred too infrequently to generate a kappa score. The SNACZ food store checklist is a first-step toward developing a valid and reliable tool to evaluate the healthfulness of food store environments faced by children. The tool can be used to compare availability of healthier snack and beverage alternatives across communities and measure change secondary to intervention. As a wider variety of healthier snack and beverage alternatives become available in food stores, the checklist should be updated.

  16. Assessing the reliability of ecotoxicological studies: An overview of current needs and approaches.

    PubMed

    Moermond, Caroline; Beasley, Amy; Breton, Roger; Junghans, Marion; Laskowski, Ryszard; Solomon, Keith; Zahner, Holly

    2017-07-01

    In general, reliable studies are well designed and well performed, and enough details on study design and performance are reported to assess the study. For hazard and risk assessment in various legal frameworks, many different types of ecotoxicity studies need to be evaluated for reliability. These studies vary in study design, methodology, quality, and level of detail reported (e.g., reviews, peer-reviewed research papers, or industry-sponsored studies documented under Good Laboratory Practice [GLP] guidelines). Regulators have the responsibility to make sound and verifiable decisions and should evaluate each study for reliability in accordance with scientific principles regardless of whether they were conducted in accordance with GLP and/or standardized methods. Thus, a systematic and transparent approach is needed to evaluate studies for reliability. In this paper, 8 different methods for reliability assessment were compared using a number of attributes: categorical versus numerical scoring methods, use of exclusion and critical criteria, weighting of criteria, whether methods are tested with case studies, domain of applicability, bias toward GLP studies, incorporation of standard guidelines in the evaluation method, number of criteria used, type of criteria considered, and availability of guidance material. Finally, some considerations are given on how to choose a suitable method for assessing reliability of ecotoxicity studies. Integr Environ Assess Manag 2017;13:640-651. © 2016 The Authors. Integrated Environmental Assessment and Management published by Wiley Periodicals, Inc. on behalf of Society of Environmental Toxicology & Chemistry (SETAC). © 2016 The Authors. Integrated Environmental Assessment and Management published by Wiley Periodicals, Inc. on behalf of Society of Environmental Toxicology & Chemistry (SETAC).

  17. Reliability of a functional test battery evaluating functionality, proprioception, and strength in recreational athletes with functional ankle instability.

    PubMed

    Sekir, U; Yildiz, Y; Hazneci, B; Ors, F; Saka, T; Aydin, T

    2008-12-01

    In contrast to the single evaluation methods used in the past, the combination of multiple tests allows one to obtain a global assessment of the ankle joint. The aim of this study was to determine the reliability of the different tests in a functional test battery. Twenty-four male recreational athletes with unilateral functional ankle instability (FAI) were recruited for this study. One component of the test battery included five different functional ability tests. These tests included a single limb hopping course, single-legged and triple-legged hop for distance, and six and cross six meter hop for time. The ankle joint position sense and one leg standing test were used for evaluation of proprioception and sensorimotor control. The isokinetic strengths of the ankle invertor and evertor muscles were evaluated at a velocity of 120 degrees /s. The reliability of the test battery was assessed by calculating the intraclass correlation coefficient (ICC). Each subject was tested two times, with an interval of 3-5 days between the test sessions. The ICCs for ankle functional and proprioceptive ability showed high reliability (ICCs ranging from 0.94 to 0.98). Additionally, isokinetic ankle joint inversion and eversion strength measurements represented good to high reliability (ICCs between 0.82 and 0.98). The functional test battery investigated in this study proved to be a reliable tool for the assessment of athletes with functional ankle instability. Therefore, clinicians may obtain reliable information from the functional test battery during the assessment of ankle joint performance in patients with functional ankle instability.

  18. The Arthroscopic Surgical Skill Evaluation Tool (ASSET).

    PubMed

    Koehler, Ryan J; Amsdell, Simon; Arendt, Elizabeth A; Bisson, Leslie J; Braman, Jonathan P; Bramen, Jonathan P; Butler, Aaron; Cosgarea, Andrew J; Harner, Christopher D; Garrett, William E; Olson, Tyson; Warme, Winston J; Nicandri, Gregg T

    2013-06-01

    Surgeries employing arthroscopic techniques are among the most commonly performed in orthopaedic clinical practice; however, valid and reliable methods of assessing the arthroscopic skill of orthopaedic surgeons are lacking. The Arthroscopic Surgery Skill Evaluation Tool (ASSET) will demonstrate content validity, concurrent criterion-oriented validity, and reliability when used to assess the technical ability of surgeons performing diagnostic knee arthroscopic surgery on cadaveric specimens. Cross-sectional study; Level of evidence, 3. Content validity was determined by a group of 7 experts using the Delphi method. Intra-articular performance of a right and left diagnostic knee arthroscopic procedure was recorded for 28 residents and 2 sports medicine fellowship-trained attending surgeons. Surgeon performance was assessed by 2 blinded raters using the ASSET. Concurrent criterion-oriented validity, interrater reliability, and test-retest reliability were evaluated. Content validity: The content development group identified 8 arthroscopic skill domains to evaluate using the ASSET. Concurrent criterion-oriented validity: Significant differences in the total ASSET score (P < .05) between novice, intermediate, and advanced experience groups were identified. Interrater reliability: The ASSET scores assigned by each rater were strongly correlated (r = 0.91, P < .01), and the intraclass correlation coefficient between raters for the total ASSET score was 0.90. Test-retest reliability: There was a significant correlation between ASSET scores for both procedures attempted by each surgeon (r = 0.79, P < .01). The ASSET appears to be a useful, valid, and reliable method for assessing surgeon performance of diagnostic knee arthroscopic surgery in cadaveric specimens. Studies are ongoing to determine its generalizability to other procedures as well as to the live operating room and other simulated environments.

  19. Rater methodology for stroboscopy: a systematic review.

    PubMed

    Bonilha, Heather Shaw; Focht, Kendrea L; Martin-Harris, Bonnie

    2015-01-01

    Laryngeal endoscopy with stroboscopy (LES) remains the clinical gold standard for assessing vocal fold function. LES is used to evaluate the efficacy of voice treatments in research studies and clinical practice. LES as a voice treatment outcome tool is only as good as the clinician interpreting the recordings. Research using LES as a treatment outcome measure should be evaluated based on rater methodology and reliability. The purpose of this literature review was to evaluate the rater-related methodology from studies that use stroboscopic findings as voice treatment outcome measures. Systematic literature review. Computerized journal databases were searched for relevant articles using terms: stroboscopy and treatment. Eligible articles were categorized and evaluated for the use of rater-related methodology, reporting of number of raters, types of raters, blinding, and rater reliability. Of the 738 articles reviewed, 80 articles met inclusion criteria. More than one-third of the studies included in the review did not report the number of raters who participated in the study. Eleven studies reported results of rater reliability analysis with only two studies reporting good inter- and intrarater reliability. The comparability and use of results from treatment studies that use LES are limited by a lack of rigor in rater methodology and variable, mostly poor, inter- and intrarater reliability. To improve our ability to evaluate and use the findings from voice treatment studies that use LES features as outcome measures, greater consistency of reporting rater methodology characteristics across studies and improved rater reliability is needed. Copyright © 2015 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  20. Inter-rater agreement in evaluation of disability: systematic review of reproducibility studies

    PubMed Central

    Barth, Jürgen; de Boer, Wout E L; Busse, Jason W; Hoving, Jan L; Kedzia, Sarah; Couban, Rachel; Fischer, Katrin; von Allmen, David Y; Spanjer, Jerry

    2017-01-01

    Objectives To explore agreement among healthcare professionals assessing eligibility for work disability benefits. Design Systematic review and narrative synthesis of reproducibility studies. Data sources Medline, Embase, and PsycINFO searched up to 16 March 2016, without language restrictions, and review of bibliographies of included studies. Eligibility criteria Observational studies investigating reproducibility among healthcare professionals performing disability evaluations using a global rating of working capacity and reporting inter-rater reliability by a statistical measure or descriptively. Studies could be conducted in insurance settings, where decisions on ability to work include normative judgments based on legal considerations, or in research settings, where decisions on ability to work disregard normative considerations.Teams of paired reviewers identified eligible studies, appraised their methodological quality and generalisability, and abstracted results with pretested forms. As heterogeneity of research designs and findings impeded a quantitative analysis, a descriptive synthesis stratified by setting (insurance or research) was performed. Results From 4562 references, 101 full text articles were reviewed. Of these, 16 studies conducted in an insurance setting and seven in a research setting, performed in 12 countries, met the inclusion criteria. Studies in the insurance setting were conducted with medical experts assessing claimants who were actual disability claimants or played by actors, hypothetical cases, or short written scenarios. Conditions were mental (n=6, 38%), musculoskeletal (n=4, 25%), or mixed (n=6, 38%). Applicability of findings from studies conducted in an insurance setting to real life evaluations ranged from generalisable (n=7, 44%) and probably generalisable (n=3, 19%) to probably not generalisable (n=6, 37%). Median inter-rater reliability among experts was 0.45 (range intraclass correlation coefficient 0.86 to κ−0.10). Inter-rater reliability was poor in six studies (37%) and excellent in only two (13%). This contrasts with studies conducted in the research setting, where the median inter-rater reliability was 0.76 (range 0.91-0.53), and 71% (5/7) studies achieved excellent inter-rater reliability. Reliability between assessing professionals was higher when the evaluation was guided by a standardised instrument (23 studies, P=0.006). No such association was detected for subjective or chronic health conditions or the studies’ generalisability to real world evaluation of disability (P=0.46, 0.45, and 0.65, respectively). Conclusions Despite their common use and far reaching consequences for workers claiming disabling injury or illness, research on the reliability of medical evaluations of disability for work is limited and indicates high variation in judgments among assessing professionals. Standardising the evaluation process could improve reliability. Development and testing of instruments and structured approaches to improve reliability in evaluation of disability are urgently needed. PMID:28122727

  1. [Instruments for evaluating oral health knowledge, attitudes and practice for parents /caregivers of small children].

    PubMed

    Martignon, Stefania; Bautista-Mendoza, Gloria; González-Carrera, María; Lafaurie-Villamil, Gloria; Morales, Veicy; Santamaría, Ruth

    2008-01-01

    Designing three instruments for evaluating oral health knowledge, attitudes and practice in parents/caregivers of low social-economic status 0-5 year-olds. Evaluating the instruments' reliability in terms of internal consistency and analysing items. Three instruments were constructed for evaluating low social-economic status 0-5 year-olds' parents/caregivers' oral health knowledge, attitudes and practice in the municipality of Usaquén , Bogotá , Colombia . 47 parents/caregivers were given a test establishing the instrument's reliability in terms of internal consistency and the adults' level of knowledge, attitudes and practice. A sub-sample was qualitatively analysed (content verification and understanding). Reliability was evaluated using Cronbach's alpha coefficient. Items were analysed for improving constructing and understanding the questions, taking four criteria into account: corrected homogeneity index (CHI), response trend, correlation between items and qualitative analysis. Cronbach's alpha coefficient for knowledge, attitudes and practice was 0,82, 0,80 and 0,62, respectively. Participants' level of knowledge, attitudes and practice was acceptable (60 %, 55 % and 91 %, respectively). This study found two out of the three evaluated instruments to be reliable (knowledge and attitudes); all three of them were then redesigned. The resulting instruments represent a valuable tool which can be used in future studies for describing and evaluating preventative programmes.

  2. An Enhanced Backbone-Assisted Reliable Framework for Wireless Sensor Networks

    PubMed Central

    Tufail, Ali; Khayam, Syed Ali; Raza, Muhammad Taqi; Ali, Amna; Kim, Ki-Hyung

    2010-01-01

    An extremely reliable source to sink communication is required for most of the contemporary WSN applications especially pertaining to military, healthcare and disaster-recovery. However, due to their intrinsic energy, bandwidth and computational constraints, Wireless Sensor Networks (WSNs) encounter several challenges in reliable source to sink communication. In this paper, we present a novel reliable topology that uses reliable hotlines between sensor gateways to boost the reliability of end-to-end transmissions. This reliable and efficient routing alternative reduces the number of average hops from source to the sink. We prove, with the help of analytical evaluation, that communication using hotlines is considerably more reliable than traditional WSN routing. We use reliability theory to analyze the cost and benefit of adding gateway nodes to a backbone-assisted WSN. However, in hotline assisted routing some scenarios where source and the sink are just a couple of hops away might bring more latency, therefore, we present a Signature Based Routing (SBR) scheme. SBR enables the gateways to make intelligent routing decisions, based upon the derived signature, hence providing lesser end-to-end delay between source to the sink communication. Finally, we evaluate our proposed hotline based topology with the help of a simulation tool and show that the proposed topology provides manifold increase in end-to-end reliability. PMID:22294890

  3. The live donor assessment tool: a psychosocial assessment tool for live organ donors.

    PubMed

    Iacoviello, Brian M; Shenoy, Akhil; Braoude, Jenna; Jennings, Tiane; Vaidya, Swapna; Brouwer, Julianna; Haydel, Brandy; Arroyo, Hansel; Thakur, Devendra; Leinwand, Joseph; Rudow, Dianne LaPointe

    2015-01-01

    Psychosocial evaluation is an important part of the live organ donor evaluation process, yet it is not standardized across institutions, and although tools exist for the psychosocial evaluation of organ recipients, none exist to assess donors. We set out to develop a semistructured psychosocial evaluation tool (the Live Donor Assessment Tool, LDAT) to assess potential live organ donors and to conduct preliminary analyses of the tool's reliability and validity. Review of the literature on the psychosocial variables associated with treatment adherence, quality of life, live organ donation outcome, and resilience, as well as review of the procedures for psychosocial evaluation at our center and other centers around the country, identified 9 domains to address; these domains were distilled into several items each, in collaboration with colleagues at transplant centers across the country, for a total of 29 items. Four raters were trained to use the LDAT, and they retrospectively scored 99 psychosocial evaluations conducted on live organ donor candidates. Reliability of the LDAT was assessed by calculating the internal consistency of the items in the scale and interrater reliability between raters; validity was estimated by comparing LDAT scores between those with a "positive" evaluation outcome and "negative" outcome. The LDAT was found to have good internal consistency, inter-rater reliability, and showed signs of validity: LDAT scores differentiated the positive vs. negative outcome groups. The LDAT demonstrated good reliability and validity, but future research on the LDAT and the ability to implement the LDAT prospectively is warranted. Copyright © 2015 The Academy of Psychosomatic Medicine. Published by Elsevier Inc. All rights reserved.

  4. Technical considerations in the evaluation of pediatric motor scales.

    PubMed

    Berk, R A; DeGangi, G A

    1979-04-01

    Guidelines are suggested for evaluating the validity and reliability of fine and gross motor scales. In the process of examining three types of validity (domain, construct, discriminant) and two types of reliability (interobserver, decision-making), it was found that there were marked deficiencies in most of the instruments currently available, particularly in the areas of discriminant validity and decision-making reliability. Each psychometric property of the scales was addressed from both scale-developer and user perspectives. An evaluative checklist is generated to assist occupational therapists who need to decide on the quality and appropriateness of a motor behavior scale for specific decision applications.

  5. Sources of medicine information and their reliability evaluated by medicine users.

    PubMed

    Närhi, Ulla

    2007-12-01

    To study the medicine users' sources of medicine information and the perceived reliability of these sources in different age groups. A computer-aided telephone interview (CATI) to Finnish consumers (n = 1,004). Those respondents (n = 714) who reported using any prescription or self-medication medicines more than once a month were included in the study. The respondents were interviewed about their use of sources of medicine information during the previous 6 months. The reliability of sources in different age groups was estimated using a 4-point scale: very reliable, somewhat reliable, somewhat unreliable and very unreliable. The respondents also had the option of being unable to make an appraisal. A proportion of respondents reporting using the source, number of mentioned sources and their reliability evaluated by respondents. About half of the respondents in each age group mentioned two to four sources. The most common sources of information were Patient Information Leaflets (PILs) (74%), doctors (68%) and pharmacists (60%). Next came television (40%), newspapers and magazines (40%), drug advertisements (32%), nurses (28%), drug information leaflets (27%), relatives and friends (24%), medicine guides and books (22%) and the Internet (20%). There was a significant difference between age groups in reporting the Internet as a source of medicine information (15-34-year-old respondents reported the greatest Internet use). The three most reliable sources in every age group were reported to be PILs, doctors and pharmacists. Nurses, drug regulatory authorities, drug information leaflets and medicine guides and books were considered next most reliable. Relatives and friends, television, newspapers and magazines were considered the least reliable. The respondents were most uncertain about the reliability of the Internet, patient organisations and telephone services. There was a significant difference between age groups in evaluating the reliability of telephone services (15-34-year-olds found them more reliable). Medicine users reported receiving medicine information from many sources. The most commonly used sources were perceived as the most reliable, but their reliability did not seem to depend on age. The counsellors should take into account that patients have many sources of medicine information, with varying validity.

  6. Computerized Analysis of Digital Photographs for Evaluation of Tooth Movement.

    PubMed

    Toodehzaeim, Mohammad Hossein; Karandish, Maryam; Karandish, Mohammad Nabi

    2015-03-01

    Various methods have been introduced for evaluation of tooth movement in orthodontics. The challenge is to adopt the most accurate and most beneficial method for patients. This study was designed to introduce analysis of digital photographs with AutoCAD software as a method to evaluate tooth movement and assess the reliability of this method. Eighteen patients were evaluated in this study. Three intraoral digital images from the buccal view were captured from each patient in half an hour interval. All the photos were sent to AutoCAD software 2011, calibrated and the distance between canine and molar hooks were measured. The data was analyzed using intraclass correlation coefficient. Photographs were found to have high reliability coefficient (P > 0.05). The introduced method is an accurate, efficient and reliable method for evaluation of tooth movement.

  7. 10 CFR 712.15 - Management evaluation.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 4 2014-01-01 2014-01-01 false Management evaluation. 712.15 Section 712.15 Energy DEPARTMENT OF ENERGY HUMAN RELIABILITY PROGRAM Establishment of and Procedures for the Human Reliability... workplace substance abuse program for DOE contractor employees, and DOE Order 3792.3, “Drug-Free Federal...

  8. 10 CFR 712.15 - Management evaluation.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 4 2012-01-01 2012-01-01 false Management evaluation. 712.15 Section 712.15 Energy DEPARTMENT OF ENERGY HUMAN RELIABILITY PROGRAM Establishment of and Procedures for the Human Reliability... workplace substance abuse program for DOE contractor employees, and DOE Order 3792.3, “Drug-Free Federal...

  9. 10 CFR 712.15 - Management evaluation.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 4 2011-01-01 2011-01-01 false Management evaluation. 712.15 Section 712.15 Energy DEPARTMENT OF ENERGY HUMAN RELIABILITY PROGRAM Establishment of and Procedures for the Human Reliability... workplace substance abuse program for DOE contractor employees, and DOE Order 3792.3, “Drug-Free Federal...

  10. 10 CFR 712.15 - Management evaluation.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 4 2013-01-01 2013-01-01 false Management evaluation. 712.15 Section 712.15 Energy DEPARTMENT OF ENERGY HUMAN RELIABILITY PROGRAM Establishment of and Procedures for the Human Reliability... workplace substance abuse program for DOE contractor employees, and DOE Order 3792.3, “Drug-Free Federal...

  11. Electric service reliability cost/worth assessment in a developing country

    NASA Astrophysics Data System (ADS)

    Pandey, Mohan Kumar

    Considerable work has been done in developed countries to optimize the reliability of electric power systems on the basis of reliability cost versus reliability worth. This has yet to be considered in most developing countries, where development plans are still based on traditional deterministic measures. The difficulty with these criteria is that they cannot be used to evaluate the economic impacts of changing reliability levels on the utility and the customers, and therefore cannot lead to an optimum expansion plan for the system. The critical issue today faced by most developing countries is that the demand for electric power is high and growth in supply is constrained by technical, environmental, and most importantly by financial impediments. Many power projects are being canceled or postponed due to a lack of resources. The investment burden associated with the electric power sector has already led some developing countries into serious debt problems. This thesis focuses on power sector issues facing by developing countries and illustrates how a basic reliability cost/worth approach can be used in a developing country to determine appropriate planning criteria and justify future power projects by application to the Nepal Integrated Electric Power System (NPS). A reliability cost/worth based system evaluation framework is proposed in this thesis. Customer surveys conducted throughout Nepal using in-person interviews with approximately 2000 sample customers are presented. The survey results indicate that the interruption cost is dependent on both customer and interruption characteristics, and it varies from one location or region to another. Assessments at both the generation and composite system levels have been performed using the customer cost data and the developed NPS reliability database. The results clearly indicate the implications of service reliability to the electricity consumers of Nepal, and show that the reliability cost/worth evaluation is both possible and practical in a developing country. The average customer interruption costs of Rs 35/kWh at Hierarchical Level I and Rs 26/kWh at Hierarchical Level II evaluated in this research work led to an optimum reserve margin of 7.5%, which is considerably lower than the traditional reserve margin of 15% used in the NPS. A similar conclusion may result in other developing countries facing difficulties in power system expansion planning using the traditional approach. A new framework for system planning is therefore recommended for developing countries which would permit an objective review of the traditional system planning approach, and the evaluation of future power projects using a new approach based on fundamental principles of power system reliability and economics.

  12. Combine Flash-Based FPGA TID and Long-Term Retention Reliabilities Through VT Shift

    NASA Astrophysics Data System (ADS)

    Wang, Jih-Jong; Rezzak, Nadia; Dsilva, Durwyn; Xue, Fengliang; Samiee, Salim; Singaraju, Pavan; Jia, James; Nguyen, Victor; Hawley, Frank; Hamdy, Esmat

    2016-08-01

    Reliability test results of data retention and total ionizing dose (TID) in 65 nm Flash-based field programmable gate array (FPGA) are presented. Long-chain inverter design is recommended for reliability evaluation because it is the worst case design for both effects. Based on preliminary test data, both issues are unified and modeled by one natural decay equation. The relative contributions of TID induced threshold-voltage shift and retention mechanisms are evaluated by analyzing test data.

  13. Reliability and the design process at Honeywell Avionics Division

    NASA Technical Reports Server (NTRS)

    Bezat, A.

    1981-01-01

    The division's philosophy for designed-in reliability and a comparison of reliability programs for space, manned military aircraft, and commercial aircraft, are presented. Topics include: the reliability interface with design and production; the concept phase through final proposal; the design, development, test and evaluation phase; the production phase; and the commonality among space, military, and commercial avionics.

  14. Manual muscle testing and hand-held dynamometry in people with inflammatory myopathy: An intra- and interrater reliability and validity study

    PubMed Central

    Baschung Pfister, Pierrette; Sterkele, Iris; Maurer, Britta; de Bie, Rob A.; Knols, Ruud H.

    2018-01-01

    Manual muscle testing (MMT) and hand-held dynamometry (HHD) are commonly used in people with inflammatory myopathy (IM), but their clinimetric properties have not yet been sufficiently studied. To evaluate the reliability and validity of MMT and HHD, maximum isometric strength was measured in eight muscle groups across three measurement events. To evaluate reliability of HHD, intra-class correlation coefficients (ICC), the standard error of measurements (SEM) and smallest detectable changes (SDC) were calculated. To measure reliability of MMT linear Cohen`s Kappa was computed for single muscle groups and ICC for total score. Additionally, correlations between MMT8 and HHD were evaluated with Spearman Correlation Coefficients. Fifty people with myositis (56±14 years, 76% female) were included in the study. Intra-and interrater reliability of HHD yielded excellent ICCs (0.75–0.97) for all muscle groups, except for interrater reliability of ankle extension (0.61). The corresponding SEMs% ranged from 8 to 28% and the SDCs% from 23 to 65%. MMT8 total score revealed excellent intra-and interrater reliability (ICC>0.9). Intrarater reliability of single muscle groups was substantial for shoulder and hip abduction, elbow and neck flexion, and hip extension (0.64–0.69); moderate for wrist (0.53) and knee extension (0.49) and fair for ankle extension (0.35). Interrater reliability was moderate for neck flexion (0.54) and hip abduction (0.44); fair for shoulder abduction, elbow flexion, wrist and ankle extension (0.20–0.33); and slight for knee extension (0.08). Correlations between the two tests were low for wrist, knee, ankle, and hip extension; moderate for elbow flexion, neck flexion and hip abduction; and good for shoulder abduction. In conclusion, the MMT8 total score is a reliable assessment to consider general muscle weakness in people with myositis but not for single muscle groups. In contrast, our results confirm that HHD can be recommended to evaluate strength of single muscle groups. PMID:29596450

  15. Bridge reliability assessment based on the PDF of long-term monitored extreme strains

    NASA Astrophysics Data System (ADS)

    Jiao, Meiju; Sun, Limin

    2011-04-01

    Structural health monitoring (SHM) systems can provide valuable information for the evaluation of bridge performance. As the development and implementation of SHM technology in recent years, the data mining and use has received increasingly attention and interests in civil engineering. Based on the principle of probabilistic and statistics, a reliability approach provides a rational basis for analysis of the randomness in loads and their effects on structures. A novel approach combined SHM systems with reliability method to evaluate the reliability of a cable-stayed bridge instrumented with SHM systems was presented in this paper. In this study, the reliability of the steel girder of the cable-stayed bridge was denoted by failure probability directly instead of reliability index as commonly used. Under the assumption that the probability distributions of the resistance are independent to the responses of structures, a formulation of failure probability was deduced. Then, as a main factor in the formulation, the probability density function (PDF) of the strain at sensor locations based on the monitoring data was evaluated and verified. That Donghai Bridge was taken as an example for the application of the proposed approach followed. In the case study, 4 years' monitoring data since the operation of the SHM systems was processed, and the reliability assessment results were discussed. Finally, the sensitivity and accuracy of the novel approach compared with FORM was discussed.

  16. Type I Interferon Controls Propagation of Long Interspersed Element-1*

    PubMed Central

    Yu, Qiujing; Carbone, Christopher J.; Katlinskaya, Yuliya V.; Zheng, Hui; Zheng, Ke; Luo, Mengcheng; Wang, P. Jeremy; Greenberg, Roger A.; Fuchs, Serge Y.

    2015-01-01

    Type I interferons (IFN) including IFNα and IFNβ are critical for the cellular defense against viruses. Here we report that increased levels of IFNβ were found in testes from mice deficient in MOV10L1, a germ cell-specific RNA helicase that plays a key role in limiting the propagation of retrotransposons including Long Interspersed Element-1 (LINE-1). Additional experiments revealed that activation of LINE-1 retrotransposons increases the expression of IFNβ and of IFN-stimulated genes. Conversely, pretreatment of cells with IFN suppressed the replication of LINE-1. Furthermore, the efficacy of LINE-1 replication was increased in isogenic cell lines harboring inactivating mutations in diverse elements of the IFN signaling pathway. Knockdown of the IFN receptor chain IFNAR1 also stimulated LINE-1 propagation in vitro. Finally, a greater accumulation of LINE-1 was found in mice that lack IFNAR1 compared with wild type mice. We propose that LINE-1-induced IFN plays an important role in restricting LINE-1 propagation and discuss the putative role of IFN in preserving the genome stability. PMID:25716322

  17. Real-time recording and classification of eye movements in an immersive virtual environment.

    PubMed

    Diaz, Gabriel; Cooper, Joseph; Kit, Dmitry; Hayhoe, Mary

    2013-10-10

    Despite the growing popularity of virtual reality environments, few laboratories are equipped to investigate eye movements within these environments. This primer is intended to reduce the time and effort required to incorporate eye-tracking equipment into a virtual reality environment. We discuss issues related to the initial startup and provide algorithms necessary for basic analysis. Algorithms are provided for the calculation of gaze angle within a virtual world using a monocular eye-tracker in a three-dimensional environment. In addition, we provide algorithms for the calculation of the angular distance between the gaze and a relevant virtual object and for the identification of fixations, saccades, and pursuit eye movements. Finally, we provide tools that temporally synchronize gaze data and the visual stimulus and enable real-time assembly of a video-based record of the experiment using the Quicktime MOV format, available at http://sourceforge.net/p/utdvrlibraries/. This record contains the visual stimulus, the gaze cursor, and associated numerical data and can be used for data exportation, visual inspection, and validation of calculated gaze movements.

  18. Real-time recording and classification of eye movements in an immersive virtual environment

    PubMed Central

    Diaz, Gabriel; Cooper, Joseph; Kit, Dmitry; Hayhoe, Mary

    2013-01-01

    Despite the growing popularity of virtual reality environments, few laboratories are equipped to investigate eye movements within these environments. This primer is intended to reduce the time and effort required to incorporate eye-tracking equipment into a virtual reality environment. We discuss issues related to the initial startup and provide algorithms necessary for basic analysis. Algorithms are provided for the calculation of gaze angle within a virtual world using a monocular eye-tracker in a three-dimensional environment. In addition, we provide algorithms for the calculation of the angular distance between the gaze and a relevant virtual object and for the identification of fixations, saccades, and pursuit eye movements. Finally, we provide tools that temporally synchronize gaze data and the visual stimulus and enable real-time assembly of a video-based record of the experiment using the Quicktime MOV format, available at http://sourceforge.net/p/utdvrlibraries/. This record contains the visual stimulus, the gaze cursor, and associated numerical data and can be used for data exportation, visual inspection, and validation of calculated gaze movements. PMID:24113087

  19. Improvement of Surge Protection by Using an AlGaN/GaN-Based Metal-Semiconductor-Metal Two-Dimensional Electron Gas Varactor

    NASA Astrophysics Data System (ADS)

    Ferng, Yi-Cherng; Chang, Liann-Be; Das, Atanu; Lin, Ching-Chi; Cheng, Chun-Yu; Kuei, Ping-Yu; Chow, Lee

    2012-12-01

    In this paper, a varactor with metal-semiconductor-metal diodes on top of the (NH4)2S/P2S5-treated AlGaN/GaN two-dimensional electron gas epitaxial structure (MSM-2DEG) is proposed to the surge protection for the first time. The sulfur-treated MSM-2DEG varactor properties, including current-voltage (I-V), capacitance-voltage (C-V), and frequency response of the proposed surge protection circuit, are presented. To verify its capability of surge protection, we replace the metal oxide varistor (MOV) and resistor (R) in a state-of-the-art surge protection circuit with the sulfur-treated MSM-2DEG varactor under the application conditions of system-level surge tests. The measured results show that the proposed surge protection circuit, consisted of a gas discharge arrester (GDA) and a sulfur-treated MSM-2DEG varactor, can suppress an electromagnetic pulse (EMP) voltage of 4000 to 360 V, a reduction of 91%, whereas suppression is to 1780 V, a reduction of 55%, when using only a GDA.

  20. Stem thrust prediction model for W-K-M double wedge parallel expanding gate valves

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eldiwany, B.; Alvarez, P.D.; Wolfe, K.

    1996-12-01

    An analytical model for determining the required valve stem thrust during opening and closing strokes of W-K-M parallel expanding gate valves was developed as part of the EPRI Motor-Operated Valve Performance Prediction Methodology (EPRI MOV PPM) Program. The model was validated against measured stem thrust data obtained from in-situ testing of three W-K-M valves. Model predictions show favorable, bounding agreement with the measured data for valves with Stellite 6 hardfacing on the disks and seat rings for water flow in the preferred flow direction (gate downstream). The maximum required thrust to open and to close the valve (excluding wedging andmore » unwedging forces) occurs at a slightly open position and not at the fully closed position. In the nonpreferred flow direction, the model shows that premature wedging can occur during {Delta}P closure strokes even when the coefficients of friction at different sliding surfaces are within the typical range. This paper summarizes the model description and comparison against test data.« less

  1. COPES Report: System Reliability Study.

    ERIC Educational Resources Information Center

    Foothill-De Anza Community Coll. District, Los Altos Hills, CA.

    The study examines the reliability of the Community College Occupational Programs Evaluation System (COPES). The COPES process is a system for evaluating program strengths and needs. A two-way test, college self-appraisal with third party validation of the self-appraisal, is utilized to assist community colleges in future institutional planning…

  2. Nurses as Evaluators of the Humanistic Behavior of Internal Medicine Residents.

    ERIC Educational Resources Information Center

    Butterfield, Paula S.; And Others

    1987-01-01

    The reliability of a 13-item questionnaire designed to assess the humanistic behaviors of internal medicine residents and the reliability of nurses as raters of those behaviors were examined. Residents were evaluated by nurses on two general medicine services and on cardiology and hematology-oncology services. (Author/MLW)

  3. A method to evaluate performance reliability of individual subjects in laboratory research applied to work settings.

    DOT National Transportation Integrated Search

    1978-10-01

    This report presents a method that may be used to evaluate the reliability of performance of individual subjects, particularly in applied laboratory research. The method is based on analysis of variance of a tasks-by-subjects data matrix, with all sc...

  4. The evaluation of advanced traveler information services (ATIS) impacts on truck travel time reliability : using the simulated yoked study concept

    DOT National Transportation Integrated Search

    2004-03-01

    The ability of Advanced Traveler Information Systems (ATIS) to improve the on-time reliability of urban truck movements is evaluated through the application of the Heuristic On-Line Web- : Linked Arrival Time Estimation (HOWLATE) methodology. In HOWL...

  5. TIGER reliability analysis in the DSN

    NASA Technical Reports Server (NTRS)

    Gunn, J. M.

    1982-01-01

    The TIGER algorithm, the inputs to the program and the output are described. TIGER is a computer program designed to simulate a system over a period of time to evaluate system reliability and availability. Results can be used in the Deep Space Network for initial spares provisioning and system evaluation.

  6. Reliability evaluation of a multistate network subject to time constraint under routing policy

    NASA Astrophysics Data System (ADS)

    Lin, Yi-Kuei

    2013-08-01

    A multistate network is a stochastic network composed of multistate arcs in which each arc has several possible capacities and may fail due to failure, maintenance, etc. The quality of a multistate network depends on how to meet the customer's requirements and how to provide the service in time. The system reliability, the probability that a given amount of data can be transmitted through a pair of minimal paths (MPs) simultaneously under the time constraint, is a proper index to evaluate the quality of a multistate network. An efficient solution procedure is first proposed to calculate it. In order to further enhance the system reliability, the network administrator decides the routing policy in advance to indicate the first and the second priority pairs of MPs. The second priority pair of MPs takes charge of the transmission duty if the first fails. The system reliability under the routing policy can be subsequently evaluated.

  7. Reliable protocol for shear wave elastography of lower limb muscles at rest and during passive stretching.

    PubMed

    Dubois, Guillaume; Kheireddine, Walid; Vergari, Claudio; Bonneau, Dominique; Thoreux, Patricia; Rouch, Philippe; Tanter, Mickael; Gennisson, Jean-Luc; Skalli, Wafa

    2015-09-01

    Development of shear wave elastography gave access to non-invasive muscle stiffness assessment in vivo. The aim of the present study was to define a measurement protocol to be used in clinical routine for quantifying the shear modulus of lower limb muscles. Four positions were defined to evaluate shear modulus in 10 healthy subjects: parallel to the fibers, in the anterior and posterior aspects of the lower limb, at rest and during passive stretching. Reliability was first evaluated on two muscles by three operators; these measurements were repeated six times. Then, measurement reliability was compared in 11 muscles by two operators; these measurements were repeated three times. Reproducibility of shear modulus was 0.48 kPa and repeatability was 0.41 kPa, with all muscles pooled. Position did not significantly influence reliability. Shear wave elastography appeared to be an appropriate and reliable tool to evaluate the shear modulus of lower limb muscles with the proposed protocol. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  8. The Data Evaluation for Obtaining Accuracy and Reliability

    NASA Astrophysics Data System (ADS)

    Kim, Chang Geun; Chae, Kyun Shik; Lee, Sang Tae; Bhang, Gun Woong

    2012-11-01

    Nemours scientific measurement results are flooded from the paper, data book, etc. as fast growing of internet. We meet many different measurement results on the same measurand. In this moment, we are face to choose most reliable one out of them. But it is not easy to choose and use the accurate and reliable data as we do at an ice cream parlor. Even expert users feel difficult to distinguish the accurate and reliable scientific data from huge amount of measurement results. For this reason, the data evaluation is getting more important as the fast growing of internet and globalization. Furthermore the expressions of measurement results are not in standardi-zation. As these need, the international movement has been enhanced. At the first step, the global harmonization of terminology used in metrology and the expression of uncertainty in measurement were published in ISO. These methods are wide spread to many area of science on their measurement to obtain the accuracy and reliability. In this paper, it is introduced that the GUM, SRD and data evaluation on atomic collisions.

  9. Inter-rater reliability of direct observations of the physical and psychosocial working conditions in eldercare: An evaluation in the DOSES project.

    PubMed

    Karstad, Kristina; Rugulies, Reiner; Skotte, Jørgen; Munch, Pernille Kold; Greiner, Birgit A; Burdorf, Alex; Søgaard, Karen; Holtermann, Andreas

    2018-05-01

    The aim of the study was to develop and evaluate the reliability of the "Danish observational study of eldercare work and musculoskeletal disorders" (DOSES) observation instrument to assess physical and psychosocial risk factors for musculoskeletal disorders (MSD) in eldercare work. During 1.5 years, sixteen raters conducted 117 inter-rater observations from 11 nursing homes. Reliability was evaluated using percent agreement and Gwet's AC1 coefficient. Of the 18 examined items, inter-rater reliability was excellent for 7 items (AC1>0.75) fair to good for 7 items (AC1 0.40-0.75) and poor for 2 items (AC1 0-0.40). For 2 items there was no agreement between the raters (AC1 <0). The reliability did not differ between the first and second half of the data collection period and the inter-rater observations were representative regarding occurrence of events in eldercare work. The instrument is appropriate for assessing physical and psychosocial risk factors for MSD among eldercare workers. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  10. Human Reliability Analysis in Support of Risk Assessment for Positive Train Control

    DOT National Transportation Integrated Search

    2003-06-01

    This report describes an approach to evaluating the reliability of human actions that are modeled in a probabilistic risk assessment : (PRA) of train control operations. This approach to human reliability analysis (HRA) has been applied in the case o...

  11. A simulation model for risk assessment of turbine wheels

    NASA Technical Reports Server (NTRS)

    Safie, Fayssal M.; Hage, Richard T.

    1991-01-01

    A simulation model has been successfully developed to evaluate the risk of the Space Shuttle auxiliary power unit (APU) turbine wheels for a specific inspection policy. Besides being an effective tool for risk/reliability evaluation, the simulation model also allows the analyst to study the trade-offs between wheel reliability, wheel life, inspection interval, and rejection crack size. For example, in the APU application, sensitivity analysis results showed that the wheel life limit has the least effect on wheel reliability when compared to the effect of the inspection interval and the rejection crack size. In summary, the simulation model developed represents a flexible tool to predict turbine wheel reliability and study the risk under different inspection policies.

  12. A simulation model for risk assessment of turbine wheels

    NASA Astrophysics Data System (ADS)

    Safie, Fayssal M.; Hage, Richard T.

    A simulation model has been successfully developed to evaluate the risk of the Space Shuttle auxiliary power unit (APU) turbine wheels for a specific inspection policy. Besides being an effective tool for risk/reliability evaluation, the simulation model also allows the analyst to study the trade-offs between wheel reliability, wheel life, inspection interval, and rejection crack size. For example, in the APU application, sensitivity analysis results showed that the wheel life limit has the least effect on wheel reliability when compared to the effect of the inspection interval and the rejection crack size. In summary, the simulation model developed represents a flexible tool to predict turbine wheel reliability and study the risk under different inspection policies.

  13. Relating Measurement Invariance, Cross-Level Invariance, and Multilevel Reliability.

    PubMed

    Jak, Suzanne; Jorgensen, Terrence D

    2017-01-01

    Data often have a nested, multilevel structure, for example when data are collected from children in classrooms. This kind of data complicate the evaluation of reliability and measurement invariance, because several properties can be evaluated at both the individual level and the cluster level, as well as across levels. For example, cross-level invariance implies equal factor loadings across levels, which is needed to give latent variables at the two levels a similar interpretation. Reliability at a specific level refers to the ratio of true score variance over total variance at that level. This paper aims to shine light on the relation between reliability, cross-level invariance, and strong factorial invariance across clusters in multilevel data. Specifically, we will illustrate how strong factorial invariance across clusters implies cross-level invariance and perfect reliability at the between level in multilevel factor models.

  14. Measurement in Sensory Modulation: The Sensory Processing Scale Assessment

    PubMed Central

    Miller, Lucy J.; Sullivan, Jillian C.

    2014-01-01

    OBJECTIVE. Sensory modulation issues have a significant impact on participation in daily life. Moreover, understanding phenotypic variation in sensory modulation dysfunction is crucial for research related to defining homogeneous groups and for clinical work in guiding treatment planning. We thus evaluated the new Sensory Processing Scale (SPS) Assessment. METHOD. Research included item development, behavioral scoring system development, test administration, and item analyses to evaluate reliability and validity across sensory domains. RESULTS. Items with adequate reliability (internal reliability >.4) and discriminant validity (p < .01) were retained. Feedback from the expert panel also contributed to decisions about retaining items in the scale. CONCLUSION. The SPS Assessment appears to be a reliable and valid measure of sensory modulation (scale reliability >.90; discrimination between group effect sizes >1.00). This scale has the potential to aid in differential diagnosis of sensory modulation issues. PMID:25184464

  15. Space flight risk data collection and analysis project: Risk and reliability database

    NASA Technical Reports Server (NTRS)

    1994-01-01

    The focus of the NASA 'Space Flight Risk Data Collection and Analysis' project was to acquire and evaluate space flight data with the express purpose of establishing a database containing measurements of specific risk assessment - reliability - availability - maintainability - supportability (RRAMS) parameters. The developed comprehensive RRAMS database will support the performance of future NASA and aerospace industry risk and reliability studies. One of the primary goals has been to acquire unprocessed information relating to the reliability and availability of launch vehicles and the subsystems and components thereof from the 45th Space Wing (formerly Eastern Space and Missile Command -ESMC) at Patrick Air Force Base. After evaluating and analyzing this information, it was encoded in terms of parameters pertinent to ascertaining reliability and availability statistics, and then assembled into an appropriate database structure.

  16. Evaluation of chondromalacia of the patellofemoral compartment with axial magnetic resonance imaging.

    PubMed

    Brown, T R; Quinn, S F

    1993-01-01

    Axial magnetic resonance (MR) imaging of the patellofemoral compartment was performed in 75 patients with arthroscopic correlation. Proton density and T2(2500/20/80) weighted images were obtained in all patients. Chondromalacia in stages I and II could not be reliably identified with MR imaging. For the evaluation of stage III and IV chondromalacia, the accuracy of MR was 89%. Focal or diffuse areas of increased or decreased signal alterations of the hyaline cartilage without a contour deformity or cartilaginous thinning do not correlate reliably with arthroscopic staging of chondromalacia. A normal signal intensity is no assurance that softening of the cartilage is not present. The most reliable indicators of chondromalacia are focal contour irregularities of the hyaline cartilage and/or thinning of the hyaline cartilage associated with high signal intensity changes within frank defects or contour irregularities with T2-weighted images. The poor MR-arthroscopic correlation in earlier stages of chondromalacia may be due in part to the subjective basis of the arthroscopic diagnosis. In conclusion, stage I and II chondromalacia of the patellofemoral compartment cannot be reliably evaluated with MR imaging. Stage III and IV chondromalacia is reliably evaluated with MR using the combination of proton density and T2-weighted images.

  17. Structural reliability assessment capability in NESSUS

    NASA Technical Reports Server (NTRS)

    Millwater, H.; Wu, Y.-T.

    1992-01-01

    The principal capabilities of NESSUS (Numerical Evaluation of Stochastic Structures Under Stress), an advanced computer code developed for probabilistic structural response analysis, are reviewed, and its structural reliability assessed. The code combines flexible structural modeling tools with advanced probabilistic algorithms in order to compute probabilistic structural response and resistance, component reliability and risk, and system reliability and risk. An illustrative numerical example is presented.

  18. Structural reliability assessment capability in NESSUS

    NASA Astrophysics Data System (ADS)

    Millwater, H.; Wu, Y.-T.

    1992-07-01

    The principal capabilities of NESSUS (Numerical Evaluation of Stochastic Structures Under Stress), an advanced computer code developed for probabilistic structural response analysis, are reviewed, and its structural reliability assessed. The code combines flexible structural modeling tools with advanced probabilistic algorithms in order to compute probabilistic structural response and resistance, component reliability and risk, and system reliability and risk. An illustrative numerical example is presented.

  19. Selection and Reporting of Statistical Methods to Assess Reliability of a Diagnostic Test: Conformity to Recommended Methods in a Peer-Reviewed Journal

    PubMed Central

    Park, Ji Eun; Han, Kyunghwa; Sung, Yu Sub; Chung, Mi Sun; Koo, Hyun Jung; Yoon, Hee Mang; Choi, Young Jun; Lee, Seung Soo; Kim, Kyung Won; Shin, Youngbin; An, Suah; Cho, Hyo-Min

    2017-01-01

    Objective To evaluate the frequency and adequacy of statistical analyses in a general radiology journal when reporting a reliability analysis for a diagnostic test. Materials and Methods Sixty-three studies of diagnostic test accuracy (DTA) and 36 studies reporting reliability analyses published in the Korean Journal of Radiology between 2012 and 2016 were analyzed. Studies were judged using the methodological guidelines of the Radiological Society of North America-Quantitative Imaging Biomarkers Alliance (RSNA-QIBA), and COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) initiative. DTA studies were evaluated by nine editorial board members of the journal. Reliability studies were evaluated by study reviewers experienced with reliability analysis. Results Thirty-one (49.2%) of the 63 DTA studies did not include a reliability analysis when deemed necessary. Among the 36 reliability studies, proper statistical methods were used in all (5/5) studies dealing with dichotomous/nominal data, 46.7% (7/15) of studies dealing with ordinal data, and 95.2% (20/21) of studies dealing with continuous data. Statistical methods were described in sufficient detail regarding weighted kappa in 28.6% (2/7) of studies and regarding the model and assumptions of intraclass correlation coefficient in 35.3% (6/17) and 29.4% (5/17) of studies, respectively. Reliability parameters were used as if they were agreement parameters in 23.1% (3/13) of studies. Reproducibility and repeatability were used incorrectly in 20% (3/15) of studies. Conclusion Greater attention to the importance of reporting reliability, thorough description of the related statistical methods, efforts not to neglect agreement parameters, and better use of relevant terminology is necessary. PMID:29089821

  20. Reduction of bias and variance for evaluation of computer-aided diagnostic schemes.

    PubMed

    Li, Qiang; Doi, Kunio

    2006-04-01

    Computer-aided diagnostic (CAD) schemes have been developed to assist radiologists in detecting various lesions in medical images. In addition to the development, an equally important problem is the reliable evaluation of the performance levels of various CAD schemes. It is good to see that more and more investigators are employing more reliable evaluation methods such as leave-one-out and cross validation, instead of less reliable methods such as resubstitution, for assessing their CAD schemes. However, the common applications of leave-one-out and cross-validation evaluation methods do not necessarily imply that the estimated performance levels are accurate and precise. Pitfalls often occur in the use of leave-one-out and cross-validation evaluation methods, and they lead to unreliable estimation of performance levels. In this study, we first identified a number of typical pitfalls for the evaluation of CAD schemes, and conducted a Monte Carlo simulation experiment for each of the pitfalls to demonstrate quantitatively the extent of bias and/or variance caused by the pitfall. Our experimental results indicate that considerable bias and variance may exist in the estimated performance levels of CAD schemes if one employs various flawed leave-one-out and cross-validation evaluation methods. In addition, for promoting and utilizing a high standard for reliable evaluation of CAD schemes, we attempt to make recommendations, whenever possible, for overcoming these pitfalls. We believe that, with the recommended evaluation methods, we can considerably reduce the bias and variance in the estimated performance levels of CAD schemes.

  1. Emulation applied to reliability analysis of reconfigurable, highly reliable, fault-tolerant computing systems

    NASA Technical Reports Server (NTRS)

    Migneault, G. E.

    1979-01-01

    Emulation techniques applied to the analysis of the reliability of highly reliable computer systems for future commercial aircraft are described. The lack of credible precision in reliability estimates obtained by analytical modeling techniques is first established. The difficulty is shown to be an unavoidable consequence of: (1) a high reliability requirement so demanding as to make system evaluation by use testing infeasible; (2) a complex system design technique, fault tolerance; (3) system reliability dominated by errors due to flaws in the system definition; and (4) elaborate analytical modeling techniques whose precision outputs are quite sensitive to errors of approximation in their input data. Next, the technique of emulation is described, indicating how its input is a simple description of the logical structure of a system and its output is the consequent behavior. Use of emulation techniques is discussed for pseudo-testing systems to evaluate bounds on the parameter values needed for the analytical techniques. Finally an illustrative example is presented to demonstrate from actual use the promise of the proposed application of emulation.

  2. Computerized Analysis of Digital Photographs for Evaluation of Tooth Movement

    PubMed Central

    Toodehzaeim, Mohammad Hossein; Karandish, Maryam; Karandish, Mohammad Nabi

    2015-01-01

    Objectives: Various methods have been introduced for evaluation of tooth movement in orthodontics. The challenge is to adopt the most accurate and most beneficial method for patients. This study was designed to introduce analysis of digital photographs with AutoCAD software as a method to evaluate tooth movement and assess the reliability of this method. Materials and Methods: Eighteen patients were evaluated in this study. Three intraoral digital images from the buccal view were captured from each patient in half an hour interval. All the photos were sent to AutoCAD software 2011, calibrated and the distance between canine and molar hooks were measured. The data was analyzed using intraclass correlation coefficient. Results: Photographs were found to have high reliability coefficient (P > 0.05). Conclusion: The introduced method is an accurate, efficient and reliable method for evaluation of tooth movement. PMID:26622272

  3. Experimental and evaluated photoneutron cross sections for 197Au

    NASA Astrophysics Data System (ADS)

    Varlamov, V.; Ishkhanov, B.; Orlin, V.

    2017-10-01

    There is a serious well-known problem of noticeable disagreements between the partial photoneutron cross sections obtained in various experiments. Such data were mainly determined using quasimonoenergetic annihilation photon beams and the method of neutron multiplicity sorting at Lawrence Livermore National Laboratory (USA) and Centre d'Etudes Nucleaires of Saclay (France). The analysis of experimental cross sections employing new objective physical data reliability criteria has shown that many of those are not reliable. The IAEA Coordinated Research Project (CRP) on photonuclear data evaluation was approved. The experimental and previously evaluated cross sections of the partial photoneutron reactions (γ ,1 n ) and (γ ,2 n ) on 197Au were analyzed using the new data reliability criteria. The data evaluated using the new experimental-theoretical method noticeably differ from both experimental data and data previously evaluated using nuclear modeling codes gnash, gunf, alice-f, and others. These discrepancies needed to be resolved.

  4. A human reliability based usability evaluation method for safety-critical software

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boring, R. L.; Tran, T. Q.; Gertman, D. I.

    2006-07-01

    Boring and Gertman (2005) introduced a novel method that augments heuristic usability evaluation methods with that of the human reliability analysis method of SPAR-H. By assigning probabilistic modifiers to individual heuristics, it is possible to arrive at the usability error probability (UEP). Although this UEP is not a literal probability of error, it nonetheless provides a quantitative basis to heuristic evaluation. This method allows one to seamlessly prioritize and identify usability issues (i.e., a higher UEP requires more immediate fixes). However, the original version of this method required the usability evaluator to assign priority weights to the final UEP, thusmore » allowing the priority of a usability issue to differ among usability evaluators. The purpose of this paper is to explore an alternative approach to standardize the priority weighting of the UEP in an effort to improve the method's reliability. (authors)« less

  5. Test-retest reliability of the Capute scales for neurodevelopmental screening of a high risk sample: Impact of test-retest interval and degree of neonatal risk.

    PubMed

    McCurdy, M; Bellows, A; Deng, D; Leppert, M; Mahone, E; Pritchard, A

    2015-01-01

    Reliable and valid screening and assessment tools are necessary to identify children at risk for neurodevelopmental disabilities who may require additional services. This study evaluated the test-retest reliability of the Capute Scales in a high-risk sample, hypothesizing adequate reliability across 6- and 12-month intervals. Capute Scales scores (N = 66) were collected via retrospective chart review from a NICU follow-up clinic within a large urban medical center spanning three age-ranges: 12-18, 19-24, and 25-36 months. On average, participants were classified as very low birth weight and premature. Reliability of the Capute Scales was evaluated with intraclass correlation coefficients across length of test-retest interval, age at testing, and degree of neonatal complications. The Capute Scales demonstrated high reliability, regardless of length of test-retest interval (ranging from 6 to 14 months) or age of participant, for all index scores, including overall Developmental Quotient (DQ), language-based skill index (CLAMS) and nonverbal reasoning index (CAT). Linear regressions revealed that greater neonatal risk was related to poorer test-retest reliability; however, reliability coefficients remained strong. The Capute Scales afford clinicians a reliable and valid means of screening and assessing for neurodevelopmental delay within high-risk infant populations.

  6. Training less-experienced faculty improves reliability of skills assessment in cardiac surgery.

    PubMed

    Lou, Xiaoying; Lee, Richard; Feins, Richard H; Enter, Daniel; Hicks, George L; Verrier, Edward D; Fann, James I

    2014-12-01

    Previous work has demonstrated high inter-rater reliability in the objective assessment of simulated anastomoses among experienced educators. We evaluated the inter-rater reliability of less-experienced educators and the impact of focused training with a video-embedded coronary anastomosis assessment tool. Nine less-experienced cardiothoracic surgery faculty members from different institutions evaluated 2 videos of simulated coronary anastomoses (1 by a medical student and 1 by a resident) at the Thoracic Surgery Directors Association Boot Camp. They then underwent a 30-minute training session using an assessment tool with embedded videos to anchor rating scores for 10 components of coronary artery anastomosis. Afterward, they evaluated 2 videos of a different student and resident performing the task. Components were scored on a 1 to 5 Likert scale, yielding an average composite score. Inter-rater reliabilities of component and composite scores were assessed using intraclass correlation coefficients (ICCs) and overall pass/fail ratings with kappa. All components of the assessment tool exhibited improvement in reliability, with 4 (bite, needle holder use, needle angles, and hand mechanics) improving the most from poor (ICC range, 0.09-0.48) to strong (ICC range, 0.80-0.90) agreement. After training, inter-rater reliabilities for composite scores improved from moderate (ICC, 0.76) to strong (ICC, 0.90) agreement, and for overall pass/fail ratings, from poor (kappa = 0.20) to moderate (kappa = 0.78) agreement. Focused, video-based anchor training facilitates greater inter-rater reliability in the objective assessment of simulated coronary anastomoses. Among raters with less teaching experience, such training may be needed before objective evaluation of technical skills. Published by Elsevier Inc.

  7. The Arthroscopic Surgical Skill Evaluation Tool (ASSET)

    PubMed Central

    Koehler, Ryan J.; Amsdell, Simon; Arendt, Elizabeth A; Bisson, Leslie J; Braman, Jonathan P; Butler, Aaron; Cosgarea, Andrew J; Harner, Christopher D; Garrett, William E; Olson, Tyson; Warme, Winston J.; Nicandri, Gregg T.

    2014-01-01

    Background Surgeries employing arthroscopic techniques are among the most commonly performed in orthopaedic clinical practice however, valid and reliable methods of assessing the arthroscopic skill of orthopaedic surgeons are lacking. Hypothesis The Arthroscopic Surgery Skill Evaluation Tool (ASSET) will demonstrate content validity, concurrent criterion-oriented validity, and reliability, when used to assess the technical ability of surgeons performing diagnostic knee arthroscopy on cadaveric specimens. Study Design Cross-sectional study; Level of evidence, 3 Methods Content validity was determined by a group of seven experts using a Delphi process. Intra-articular performance of a right and left diagnostic knee arthroscopy was recorded for twenty-eight residents and two sports medicine fellowship trained attending surgeons. Subject performance was assessed by two blinded raters using the ASSET. Concurrent criterion-oriented validity, inter-rater reliability, and test-retest reliability were evaluated. Results Content validity: The content development group identified 8 arthroscopic skill domains to evaluate using the ASSET. Concurrent criterion-oriented validity: Significant differences in total ASSET score (p<0.05) between novice, intermediate, and advanced experience groups were identified. Inter-rater reliability: The ASSET scores assigned by each rater were strongly correlated (r=0.91, p <0.01) and the intra-class correlation coefficient between raters for the total ASSET score was 0.90. Test-retest reliability: there was a significant correlation between ASSET scores for both procedures attempted by each individual (r = 0.79, p<0.01). Conclusion The ASSET appears to be a useful, valid, and reliable method for assessing surgeon performance of diagnostic knee arthroscopy in cadaveric specimens. Studies are ongoing to determine its generalizability to other procedures as well as to the live OR and other simulated environments. PMID:23548808

  8. Reliability and Validity of Survey Instruments to Measure Work-Related Fatigue in the Emergency Medical Services Setting: A Systematic Review.

    PubMed

    Patterson, P Daniel; Weaver, Matthew D; Fabio, Anthony; Teasley, Ellen M; Renn, Megan L; Curtis, Brett R; Matthews, Margaret E; Kroemer, Andrew J; Xun, Xiaoshuang; Bizhanova, Zhadyra; Weiss, Patricia M; Sequeira, Denisse J; Coppler, Patrick J; Lang, Eddy S; Higgins, J Stephen

    2018-02-15

    This study sought to systematically search the literature to identify reliable and valid survey instruments for fatigue measurement in the Emergency Medical Services (EMS) occupational setting. A systematic review study design was used and searched six databases, including one website. The research question guiding the search was developed a priori and registered with the PROSPERO database of systematic reviews: "Are there reliable and valid instruments for measuring fatigue among EMS personnel?" (2016:CRD42016040097). The primary outcome of interest was criterion-related validity. Important outcomes of interest included reliability (e.g., internal consistency), and indicators of sensitivity and specificity. Members of the research team independently screened records from the databases. Full-text articles were evaluated by adapting the Bolster and Rourke system for categorizing findings of systematic reviews, and the rated data abstracted from the body of literature as favorable, unfavorable, mixed/inconclusive, or no impact. The Grading of Recommendations, Assessment, Development and Evaluation (GRADE) methodology was used to evaluate the quality of evidence. The search strategy yielded 1,257 unique records. Thirty-four unique experimental and non-experimental studies were determined relevant following full-text review. Nineteen studies reported on the reliability and/or validity of ten different fatigue survey instruments. Eighteen different studies evaluated the reliability and/or validity of four different sleepiness survey instruments. None of the retained studies reported sensitivity or specificity. Evidence quality was rated as very low across all outcomes. In this systematic review, limited evidence of the reliability and validity of 14 different survey instruments to assess the fatigue and/or sleepiness status of EMS personnel and related shift worker groups was identified.

  9. Interim reliability evaluation program, Browns Ferry fault trees

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stewart, M.E.

    1981-01-01

    An abbreviated fault tree method is used to evaluate and model Browns Ferry systems in the Interim Reliability Evaluation programs, simplifying the recording and displaying of events, yet maintaining the system of identifying faults. The level of investigation is not changed. The analytical thought process inherent in the conventional method is not compromised. But the abbreviated method takes less time, and the fault modes are much more visible.

  10. Reliability and validity of a quantitative color scale to evaluate masticatory performance using color-changeable chewing gum.

    PubMed

    Hama, Yohei; Kanazawa, Manabu; Minakuchi, Shunsuke; Uchida, Tatsuro; Sasaki, Yoshiyuki

    2014-03-19

    In the present study, we developed a novel color scale for visual assessment, conforming to theoretical color changes of a gum, to evaluate masticatoryperformance; moreover, we investigated the reliability and validity of this evaluation method using the color scale. Ten participants (aged 26.30 years) with natural dentition chewed the gum at several chewing strokes. Changes in color were measured using a colorimeter, and then, linearregression expressions that represented changes in gum color were derived. The color scale was developed using these regression expressions. Thirty-two chewed gums were evaluated using colorimeter and were assessed three times using the color scale by six dentists aged 25.27 (mean, 25.8) years, six preclinical dental students aged 21.23 (mean, 22.2) years, and six elderly individuals aged 68.84 (mean, 74.0) years. The intrarater and interrater reliability of evaluations was assessed using intraclass correlation coefficients. Validity of the method compared with a colorimeter was assessed using Spearman's rank correlation coefficient. All intraclass correlation coefficients were > 0.90, and Spearman's rank-correlation coefficients were > 0.95 in all groups. These results indicated that the evaluation method of the color-changeable chewing gum using the newly developed color scale is reliable and valid.

  11. Evaluating training of screening, brief intervention, and referral to treatment (SBIRT) for substance use: Reliability of the MD3 SBIRT Coding Scale.

    PubMed

    DiClemente, Carlo C; Crouch, Taylor Berens; Norwood, Amber E Q; Delahanty, Janine; Welsh, Christopher

    2015-03-01

    Screening, brief intervention, and referral to treatment (SBIRT) has become an empirically supported and widely implemented approach in primary and specialty care for addressing substance misuse. Accordingly, training of providers in SBIRT has increased exponentially in recent years. However, the quality and fidelity of training programs and subsequent interventions are largely unknown because of the lack of SBIRT-specific evaluation tools. The purpose of this study was to create a coding scale to assess quality and fidelity of SBIRT interactions addressing alcohol, tobacco, illicit drugs, and prescription medication misuse. The scale was developed to evaluate performance in an SBIRT residency training program. Scale development was based on training protocol and competencies with consultation from Motivational Interviewing coding experts. Trained medical residents practiced SBIRT with standardized patients during 10- to 15-min videotaped interactions. This study included 25 tapes from the Family Medicine program coded by 3 unique coder pairs with varying levels of coding experience. Interrater reliability was assessed for overall scale components and individual items via intraclass correlation coefficients. Coder pair-specific reliability was also assessed. Interrater reliability was excellent overall for the scale components (>.85) and nearly all items. Reliability was higher for more experienced coders, though still adequate for the trained coder pair. Descriptive data demonstrated a broad range of adherence and skills. Subscale correlations supported concurrent and discriminant validity. Data provide evidence that the MD3 SBIRT Coding Scale is a psychometrically reliable coding system for evaluating SBIRT interactions and can be used to evaluate implementation skills for fidelity, training, assessment, and research. Recommendations for refinement and further testing of the measure are discussed. (PsycINFO Database Record (c) 2015 APA, all rights reserved).

  12. Introducing the Professionalism Mini-Evaluation Exercise (P-MEX) in Japan: results from a multicenter, cross-sectional study.

    PubMed

    Tsugawa, Yusuke; Ohbu, Sadayoshi; Cruess, Richard; Cruess, Sylvia; Okubo, Tomoya; Takahashi, Osamu; Tokuda, Yasuharu; Heist, Brian S; Bito, Seiji; Itoh, Toshiyuki; Aoki, Akiko; Chiba, Tsutomu; Fukui, Tsuguya

    2011-08-01

    Despite the growing importance of and interest in medical professionalism, there is no standardized tool for its measurement. The authors sought to verify the validity, reliability, and generalizability of the Professionalism Mini-Evaluation Exercise (P-MEX), a previously developed and tested tool, in the context of Japanese hospitals. A multicenter, cross-sectional evaluation study was performed to investigate the validity, reliability, and generalizability of the P-MEX in seven Japanese hospitals. In 2009-2010, 378 evaluators (attending physicians, nurses, peers, and junior residents) completed 360-degree assessments of 165 residents and fellows using the P-MEX. The content validity and criterion-related validity were examined, and the construct validity of the P-MEX was investigated by performing confirmatory factor analysis through a structural equation model. The reliability was tested using generalizability analysis. The contents of the P-MEX achieved good acceptance in a preliminary working group, and the poststudy survey revealed that 302 (79.9%) evaluators rated the P-MEX items as appropriate, indicating good content validity. The correlation coefficient between P-MEX scores and external criteria was 0.78 (P < .001), demonstrating good criterion-related validity. Confirmatory factor analysis verified high path coefficient (0.60-0.99) and adequate goodness of fit of the model. The generalizability analysis yielded a high dependability coefficient, suggesting good reliability, except when evaluators were peers or junior residents. Findings show evidence of adequate validity, reliability, and generalizability of the P-MEX in Japanese hospital settings. The P-MEX is the only evaluation tool for medical professionalism verified in both a Western and East Asian cultural context.

  13. Intra-and inter-observer reliability of nailfold videocapillaroscopy - A possible outcome measure for systemic sclerosis-related microangiopathy.

    PubMed

    Dinsdale, Graham; Moore, Tonia; O'Leary, Neil; Tresadern, Philip; Berks, Michael; Roberts, Christopher; Manning, Joanne; Allen, John; Anderson, Marina; Cutolo, Maurizio; Hesselstrand, Roger; Howell, Kevin; Pizzorni, Carmen; Smith, Vanessa; Sulli, Alberto; Wildt, Marie; Taylor, Christopher; Murray, Andrea; Herrick, Ariane L

    2017-07-01

    Our aim was to assess the reliability of nailfold capillary assessment in terms of image evaluability, image severity grade ('normal', 'early', 'active', 'late'), capillary density, capillary (apex) width, and presence of giant capillaries, and also to gain further insight into differences in these parameters between patients with systemic sclerosis (SSc), patients with primary Raynaud's phenomenon (PRP) and healthy control subjects. Videocapillaroscopy images (magnification 300×) were acquired from all 10 digits from 173 participants: 101 patients with SSc, 22 with PRP and 50 healthy controls. Ten capillaroscopy experts from 7 European centres evaluated the images. Custom image mark-up software allowed extraction of the following outcome measures: overall grade ('normal', 'early', 'active', 'late', 'non-specific', or 'ungradeable'), capillary density (vessels/mm), mean vessel apical width, and presence of giant capillaries. Observers analysed a median of 129 images each. Evaluability (i.e. the availability of measures) varied across outcome measures (e.g. 73.0% for density and 46.2% for overall grade in patients with SSc). Intra-observer reliability for evaluability was consistently higher than inter- (e.g. for density, intra-class correlation coefficient [ICC] was 0.71 within and 0.14 between observers). Conditional on evaluability, both intra- and inter-observer reliability were high for grade (ICC 0.93 and 0.78 respectively), density (0.91 and 0.64) and width (0.91 and 0.85). Evaluability is one of the major challenges in assessing nailfold capillaries. However, when images are evaluable, the high intra- and inter-reliabilities suggest that overall image grade, capillary density and apex width have potential as outcome measures in longitudinal studies. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Quality Evaluation Scores are no more Reliable than Gestalt in Evaluating the Quality of Emergency Medicine Blogs: A METRIQ Study.

    PubMed

    Thoma, Brent; Sebok-Syer, Stefanie S; Colmers-Gray, Isabelle; Sherbino, Jonathan; Ankel, Felix; Trueger, N Seth; Grock, Andrew; Siemens, Marshall; Paddock, Michael; Purdy, Eve; Kenneth Milne, William; Chan, Teresa M

    2018-01-30

    Construct: We investigated the quality of emergency medicine (EM) blogs as educational resources. Online medical education resources such as blogs are increasingly used by EM trainees and clinicians. However, quality evaluations of these resources using gestalt are unreliable. We investigated the reliability of two previously derived quality evaluation instruments for blogs. Sixty English-language EM websites that published clinically oriented blog posts between January 1 and February 24, 2016, were identified. A random number generator selected 10 websites, and the 2 most recent clinically oriented blog posts from each site were evaluated using gestalt, the Academic Life in Emergency Medicine (ALiEM) Approved Instructional Resources (AIR) score, and the Medical Education Translational Resources: Impact and Quality (METRIQ-8) score, by a sample of medical students, EM residents, and EM attendings. Each rater evaluated all 20 blog posts with gestalt and 15 of the 20 blog posts with the ALiEM AIR and METRIQ-8 scores. Pearson's correlations were calculated between the average scores for each metric. Single-measure intraclass correlation coefficients (ICCs) evaluated the reliability of each instrument. Our study included 121 medical students, 88 EM residents, and 100 EM attendings who completed ratings. The average gestalt rating of each blog post correlated strongly with the average scores for ALiEM AIR (r = .94) and METRIQ-8 (r = .91). Single-measure ICCs were fair for gestalt (0.37, IQR 0.25-0.56), ALiEM AIR (0.41, IQR 0.29-0.60) and METRIQ-8 (0.40, IQR 0.28-0.59). The average scores of each blog post correlated strongly with gestalt ratings. However, neither ALiEM AIR nor METRIQ-8 showed higher reliability than gestalt. Improved reliability may be possible through rater training and instrument refinement.

  15. [Intra-rater Reliability for the Questionnaire on Activity Limitations and Participation Restrictions of Children With ADHD].

    PubMed

    Salamanca Duque, Luisa Matilde; Naranjo Aristizábal, María Mercedes; Gutiérrez Ríos, Gladys Helena; Prieto, Jaime Bayona

    2014-03-01

    Questionnaires for evaluating activity limitations and participation restrictions in children with ADHD (CLARP-TDAH) has recently been developed in Colombia, based on the suggestions made by the WHO from the International Classification of Functioning, Disability and Health (ICF), allowing clinical evaluation beyond an evaluation of the functionality and functioning of children in their family and school environments. Previous research with the questionnaire proved useful in the multidisciplinary approach of Colombian children with ADHD. This study determines the level of intra-rater reliability for questionnaires CLARP-TDAH Parents and Teachers. The study included a non-random sample of 203 Colombian children attending school and diagnosed with ADHD. Intra-rater reliability and the reproducibility of the results was determined using the Kappa index. The informants were parents and teachers. Kappa values >0.7 were obtained for the intra-rater reliability of the questionnaire domains of CLARP-TDAH Parents, while for CLARP-TDAH Teachers domains these values were >0.8. CLARP-TDAH questionnaires are a tool with a good level of intra-rater reliability, which allows a reliable assessment of activity limitations and participation restrictions in order to determine the level of functioning at home and school. Copyright © 2014 Asociación Colombiana de Psiquiatría. Publicado por Elsevier España. All rights reserved.

  16. The Validity and Reliability Test of the Indonesian Version of Gastroesophageal Reflux Disease Quality of Life (GERD-QOL) Questionnaire.

    PubMed

    Siahaan, Laura A; Syam, Ari F; Simadibrata, Marcellus; Setiati, Siti

    2017-01-01

    to obtain a valid and reliable GERD-QOL questionnaire for Indonesian application. at the initial stage, the GERD-QOL questionnaire was first translated into Indonesian language and the translated questionnaire was subsequently translated back into the original language (back-to-back translation). The results were evaluated by the researcher team and therefore, an Indonesian version of GERD-QOL questionnaire was developed. Ninety-one patients who had been clinically diagnosed with GERD based on the Montreal criteria were interviewed using the Indonesian version of GERD-QOL questionnaire and the SF 36 questionnaire. The validity was evaluated using a method of construct validity and external validity, and reliability can be tested by the method of internal consistency and test retest. the Indonesian version of GERD-QOL questionnaire had a good internal consistency reliability with a Cronbach Alpha of 0.687-0.842 and a good test retest reliability with an intra-class correlation coefficient of 0.756-0.936; p<0.05). The questionnaire had also been demonstrated to have a good validity with a proven high correlation to each question of SF-36 (p<0.05). the Indonesian version of GERD-QOL questionnaire has been proven valid and reliable to evaluate the quality of life of GERD patients.

  17. Dental hygiene faculty calibration in the evaluation of calculus detection.

    PubMed

    Garland, Kandis V; Newell, Kathleen J

    2009-03-01

    The purpose of this pilot study was to explore the impact of faculty calibration training on intra- and interrater reliability regarding calculus detection. After IRB approval, twelve dental hygiene faculty members were recruited from a pool of twenty-two for voluntary participation and randomized into two groups. All subjects provided two pre- and two posttest scorings of calculus deposits on each of three typodonts by recording yes or no indicating if they detected calculus. Accuracy and consistency of calculus detection were evaluated using an answer key. The experimental group received three two-hour training sessions to practice a prescribed exploring sequence and technique for calculus detection. Participants immediately corrected their answers, received feedback from the trainer, and reconciled missed areas. Intra- and interrater reliability (pre- and posttest) was determined using Cohen's Kappa and compared between groups using repeated measures (split-plot) ANOVA. The groups did not differ from pre- to posttraining (intrarater reliability p=0.64; interrater reliability p=0.20). Training had no effect on reliability levels for simulated calculus detection in this study. Recommendations for future studies of faculty calibration when evaluating students include using patients for assessing rater reliability, employing larger samples at multiple sites, and assessing the impact on students' attitudes and learning outcomes.

  18. Test-retest reliability of the safe driving behavior measure for community-dwelling elderly drivers.

    PubMed

    Song, Chiang-Soon; Lee, Joo-Hyun; Han, Sang-Woo

    2016-06-01

    [Purpose] The Safe Driving Behavior Measure (SDBM) is a self-report measurement tools that assesses the safe-driving behaviors of the elderly. The purpose of this study was to evaluate the test-retest reliability of the SDBM among community-dwelling elderly drivers. [Subjects and Methods] A total of sixty-one community-dwelling elderly were enrolled to investigate the reliability of the SDBM. The SDBM was assessed in two sessions that were conducted three days apart in a quiet and well-organized assessment room. That test-retest reliability of overall scores and three domain scores of the SDBM were statistically evaluated using intraclass correlation coefficients [ICC (2.1)]. Pearson correlation coefficients were used to quantify bivariate associations among the three domains of the SDBM. [Results] The SDBM demonstrated excellent rest-retest reliability for community-dwelling elderly drivers. The Cronbach alpha coefficients of the three domains of person-vehicle (0.979), person-environment (0.944), and person-vehicle-environment (0.971) of the SDBM indicate high internal consistency. [Conclusion] The results of this study suggest that the SDBM is a reliable measure for evaluating the safe- driving of automobiles by community-dwelling elderly, and is adequate for detecting changes in scores in clinical settings.

  19. Evaluating the Performance of the IEEE Standard 1366 Method for Identifying Major Event Days

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eto, Joseph H.; LaCommare, Kristina Hamachi; Sohn, Michael D.

    IEEE Standard 1366 offers a method for segmenting reliability performance data to isolate the effects of major events from the underlying year-to-year trends in reliability. Recent analysis by the IEEE Distribution Reliability Working Group (DRWG) has found that reliability performance of some utilities differs from the expectations that helped guide the development of the Standard 1366 method. This paper proposes quantitative metrics to evaluate the performance of the Standard 1366 method in identifying major events and in reducing year-to-year variability in utility reliability. The metrics are applied to a large sample of utility-reported reliability data to assess performance of themore » method with alternative specifications that have been considered by the DRWG. We find that none of the alternatives perform uniformly 'better' than the current Standard 1366 method. That is, none of the modifications uniformly lowers the year-to-year variability in System Average Interruption Duration Index without major events. Instead, for any given alternative, while it may lower the value of this metric for some utilities, it also increases it for other utilities (sometimes dramatically). Thus, we illustrate some of the trade-offs that must be considered in using the Standard 1366 method and highlight the usefulness of the metrics we have proposed in conducting these evaluations.« less

  20. Reliability and validity of the revised Gibson Test of Cognitive Skills, a computer-based test battery for assessing cognition across the lifespan.

    PubMed

    Moore, Amy Lawson; Miller, Terissa M

    2018-01-01

    The purpose of the current study is to evaluate the validity and reliability of the revised Gibson Test of Cognitive Skills, a computer-based battery of tests measuring short-term memory, long-term memory, processing speed, logic and reasoning, visual processing, as well as auditory processing and word attack skills. This study included 2,737 participants aged 5-85 years. A series of studies was conducted to examine the validity and reliability using the test performance of the entire norming group and several subgroups. The evaluation of the technical properties of the test battery included content validation by subject matter experts, item analysis and coefficient alpha, test-retest reliability, split-half reliability, and analysis of concurrent validity with the Woodcock Johnson III Tests of Cognitive Abilities and Tests of Achievement. Results indicated strong sources of evidence of validity and reliability for the test, including internal consistency reliability coefficients ranging from 0.87 to 0.98, test-retest reliability coefficients ranging from 0.69 to 0.91, split-half reliability coefficients ranging from 0.87 to 0.91, and concurrent validity coefficients ranging from 0.53 to 0.93. The Gibson Test of Cognitive Skills-2 is a reliable and valid tool for assessing cognition in the general population across the lifespan.

  1. An improved spanning tree approach for the reliability analysis of supply chain collaborative network

    NASA Astrophysics Data System (ADS)

    Lam, C. Y.; Ip, W. H.

    2012-11-01

    A higher degree of reliability in the collaborative network can increase the competitiveness and performance of an entire supply chain. As supply chain networks grow more complex, the consequences of unreliable behaviour become increasingly severe in terms of cost, effort and time. Moreover, it is computationally difficult to calculate the network reliability of a Non-deterministic Polynomial-time hard (NP-hard) all-terminal network using state enumeration, as this may require a huge number of iterations for topology optimisation. Therefore, this paper proposes an alternative approach of an improved spanning tree for reliability analysis to help effectively evaluate and analyse the reliability of collaborative networks in supply chains and reduce the comparative computational complexity of algorithms. Set theory is employed to evaluate and model the all-terminal reliability of the improved spanning tree algorithm and present a case study of a supply chain used in lamp production to illustrate the application of the proposed approach.

  2. Validity and Reliability of Clinical Examination in the Diagnosis of Myofascial Pain Syndrome and Myofascial Trigger Points in Upper Quarter Muscles.

    PubMed

    Mayoral Del Moral, Orlando; Torres Lacomba, María; Russell, I Jon; Sánchez Méndez, Óscar; Sánchez Sánchez, Beatriz

    2017-12-15

    To determine whether two independent examiners can agree on a diagnosis of myofascial pain syndrome (MPS). To evaluate interexaminer reliability in identifying myofascial trigger points in upper quarter muscles. To evaluate the reliability of clinical diagnostic criteria for the diagnosis of MPS. To evaluate the validity of clinical diagnostic criteria for the diagnosis of MPS. Validity and reliability study. Provincial Hospital. Toledo, Spain. Twenty myofascial pain syndrome patients and 20 healthy, normal control subjects, enrolled by a trained and experienced examiner. Ten bilateral muscles from the upper quarter were evaluated by two experienced examiners. The second examiner was blinded to the diagnosis group. The MPS diagnosis required at least one muscle to have an active myofascial trigger point. Three to four days separated the two examinations. The primary outcome measure was the frequency with which the two examiners agreed on the classification of the subjects as patients or as healthy controls. The kappa statistic (K) was used to determine the level of agreement between both examinations, interpreted as very good (0.81-1.00), good (0.61-0.80), moderate (0.41-0.60), fair (0.21-0.40), or poor (≤0.20). Interexaminer reliability for identifying subjects with MPS was very good (K = 1.0). Interexaminer reliability for identifying muscles leading to a diagnosis of MPS was also very good (K = 0.81). Sensitivity and specificity showed high values for most examination tests in all muscles, which confirms the validity of clinical diagnostic criteria in the diagnosis of MPS. Interrater reliability between two expert examiners identifying subjects with MPS involving upper quarter muscles exhibited substantial agreement. These results suggest that clinical criteria can be valid and reliable in the diagnosis of this condition. © 2017 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  3. [Reliability and validity analysis of simplified Chinese version of QOL questionnaire of olfactory disorders].

    PubMed

    Jin, X F; Wang, J; Li, Y J; Liu, J F; Ni, D F

    2016-09-20

    Objective: To cross-culturally translate the questionnaire of olfactory disorders(QOD)into a simplified Chinese version, and evaluate its reliability and validity in clinical. Method: A simplified Chinese version of the QOD was evaluated in test-retest reliability, split-half reliability and internal consistency.Then it was evaluated in validity test including content validity, criterion-related validity, responsibility. Criterion-related validity was using the medical outcome study's 36-item short rorm health survey(SF-36) and the World Health Organization quality of life-brief (WHOQOL-BREF) for comparison. Result: A total of 239 patients with olfactory dysfunction were enrolled and tested, in which 195 patients completed all three surveys(QOD, SF-36, WHOQOL-BREF). The test-retest reliabilities of the QOD-parosmia statements(QOD-P), QOD-quality of life(QOD-QoL), and the QOD-visual simulation(QOD-VAS)sections were 0.799( P <0.01),0.781( P <0.01),0.488( P <0.01), respectively, and the Cronbach' s α coefficients reliability were 0.477,0.812,0.889,respectively.The split-half reliability of QOD-QoL was 0.89. There was no correlation between the QOD-P section and the SF-36, but there were statistically significant correlations between the QOD-QoL and QOD-VAS sections with the SF-36. There was no correlation between the QOD-P section and the WHOQOL-BREF, but there were statistically significant correlations between the QOD-QoL and QOD-VAS sections with the SF-36 in most sections. Conclusion: The simplified Chinese version of the QOD was testified to be a reliable and valid questionnaire for evaluating patients with olfactory dysfunction living in mainland of China.The QOD-P section needs further modifications to properly adapt patients with Chinese cultural and knowledge background. Copyright© by the Editorial Department of Journal of Clinical Otorhinolaryngology Head and Neck Surgery.

  4. The reliability of WorkWell Systems Functional Capacity Evaluation: a systematic review

    PubMed Central

    2014-01-01

    Background Functional capacity evaluation (FCE) determines a person’s ability to perform work-related tasks and is a major component of the rehabilitation process. The WorkWell Systems (WWS) FCE (formerly known as Isernhagen Work Systems FCE) is currently the most commonly used FCE tool in German rehabilitation centres. Our systematic review investigated the inter-rater, intra-rater and test-retest reliability of the WWS FCE. Methods We performed a systematic literature search of studies on the reliability of the WWS FCE and extracted item-specific measures of inter-rater, intra-rater and test-retest reliability from the identified studies. Intraclass correlation coefficients ≥ 0.75, percentages of agreement ≥ 80%, and kappa coefficients ≥ 0.60 were categorised as acceptable, otherwise they were considered non-acceptable. The extracted values were summarised for the five performance categories of the WWS FCE, and the results were classified as either consistent or inconsistent. Results From 11 identified studies, 150 item-specific reliability measures were extracted. 89% of the extracted inter-rater reliability measures, all of the intra-rater reliability measures and 96% of the test-retest reliability measures of the weight handling and strength tests had an acceptable level of reliability, compared to only 67% of the test-retest reliability measures of the posture/mobility tests and 56% of the test-retest reliability measures of the locomotion tests. Both of the extracted test-retest reliability measures of the balance test were acceptable. Conclusions Weight handling and strength tests were found to have consistently acceptable reliability. Further research is needed to explore the reliability of the other tests as inconsistent findings or a lack of data prevented definitive conclusions. PMID:24674029

  5. Bayesian Meta-Analysis of Cronbach's Coefficient Alpha to Evaluate Informative Hypotheses

    ERIC Educational Resources Information Center

    Okada, Kensuke

    2015-01-01

    This paper proposes a new method to evaluate informative hypotheses for meta-analysis of Cronbach's coefficient alpha using a Bayesian approach. The coefficient alpha is one of the most widely used reliability indices. In meta-analyses of reliability, researchers typically form specific informative hypotheses beforehand, such as "alpha of…

  6. Evaluation of Scale Reliability with Binary Measures Using Latent Variable Modeling

    ERIC Educational Resources Information Center

    Raykov, Tenko; Dimitrov, Dimiter M.; Asparouhov, Tihomir

    2010-01-01

    A method for interval estimation of scale reliability with discrete data is outlined. The approach is applicable with multi-item instruments consisting of binary measures, and is developed within the latent variable modeling methodology. The procedure is useful for evaluation of consistency of single measures and of sum scores from item sets…

  7. The Universal Design for Play Tool: Establishing Validity and Reliability

    ERIC Educational Resources Information Center

    Ruffino, Amy Goetz; Mistrett, Susan G.; Tomita, Machiko; Hajare, Poonam

    2006-01-01

    The Universal Design for Play (UDP) Tool is an instrument designed to evaluate the presence of universal design (UD) features in toys. This study evaluated its psychometric properties, including content validity, construct validity, and test-retest reliability. The UDP tool was designed to assist in selecting toys most appropriate for children…

  8. An Evaluation of the Technical Adequacy of a Revised Measure of Quality Indicators of Transition

    ERIC Educational Resources Information Center

    Morningstar, Mary E.; Lee, Hyunjoo; Lattin, Dana L.; Murray, Angela K.

    2016-01-01

    This study confirmed the reliability and validity of the Quality Indicators of Exemplary Transition Programs Needs Assessment-2 (QI-2). Quality transition program indicators were identified through a systematic synthesis of transition research, policies, and program evaluation measures. To verify reliability and validity of the QI-2, we…

  9. Evaluation of Weighted Scale Reliability and Criterion Validity: A Latent Variable Modeling Approach

    ERIC Educational Resources Information Center

    Raykov, Tenko

    2007-01-01

    A method is outlined for evaluating the reliability and criterion validity of weighted scales based on sets of unidimensional measures. The approach is developed within the framework of latent variable modeling methodology and is useful for point and interval estimation of these measurement quality coefficients in counseling and education…

  10. Value-Added Models for Teacher Preparation Programs: Validity and Reliability Threats, and a Manageable Alternative

    ERIC Educational Resources Information Center

    Brady, Michael P.; Heiser, Lawrence A.; McCormick, Jazarae K.; Forgan, James

    2016-01-01

    High-stakes standardized student assessments are increasingly used in value-added evaluation models to connect teacher performance to P-12 student learning. These assessments are also being used to evaluate teacher preparation programs, despite validity and reliability threats. A more rational model linking student performance to candidates who…

  11. Inter-rater agreement in evaluation of disability: systematic review of reproducibility studies.

    PubMed

    Barth, Jürgen; de Boer, Wout E L; Busse, Jason W; Hoving, Jan L; Kedzia, Sarah; Couban, Rachel; Fischer, Katrin; von Allmen, David Y; Spanjer, Jerry; Kunz, Regina

    2017-01-25

     To explore agreement among healthcare professionals assessing eligibility for work disability benefits.  Systematic review and narrative synthesis of reproducibility studies.  Medline, Embase, and PsycINFO searched up to 16 March 2016, without language restrictions, and review of bibliographies of included studies.  Observational studies investigating reproducibility among healthcare professionals performing disability evaluations using a global rating of working capacity and reporting inter-rater reliability by a statistical measure or descriptively. Studies could be conducted in insurance settings, where decisions on ability to work include normative judgments based on legal considerations, or in research settings, where decisions on ability to work disregard normative considerations. : Teams of paired reviewers identified eligible studies, appraised their methodological quality and generalisability, and abstracted results with pretested forms. As heterogeneity of research designs and findings impeded a quantitative analysis, a descriptive synthesis stratified by setting (insurance or research) was performed.  From 4562 references, 101 full text articles were reviewed. Of these, 16 studies conducted in an insurance setting and seven in a research setting, performed in 12 countries, met the inclusion criteria. Studies in the insurance setting were conducted with medical experts assessing claimants who were actual disability claimants or played by actors, hypothetical cases, or short written scenarios. Conditions were mental (n=6, 38%), musculoskeletal (n=4, 25%), or mixed (n=6, 38%). Applicability of findings from studies conducted in an insurance setting to real life evaluations ranged from generalisable (n=7, 44%) and probably generalisable (n=3, 19%) to probably not generalisable (n=6, 37%). Median inter-rater reliability among experts was 0.45 (range intraclass correlation coefficient 0.86 to κ-0.10). Inter-rater reliability was poor in six studies (37%) and excellent in only two (13%). This contrasts with studies conducted in the research setting, where the median inter-rater reliability was 0.76 (range 0.91-0.53), and 71% (5/7) studies achieved excellent inter-rater reliability. Reliability between assessing professionals was higher when the evaluation was guided by a standardised instrument (23 studies, P=0.006). No such association was detected for subjective or chronic health conditions or the studies' generalisability to real world evaluation of disability (P=0.46, 0.45, and 0.65, respectively).  Despite their common use and far reaching consequences for workers claiming disabling injury or illness, research on the reliability of medical evaluations of disability for work is limited and indicates high variation in judgments among assessing professionals. Standardising the evaluation process could improve reliability. Development and testing of instruments and structured approaches to improve reliability in evaluation of disability are urgently needed. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  12. Care 3, Phase 1, volume 1

    NASA Technical Reports Server (NTRS)

    Stiffler, J. J.; Bryant, L. A.; Guccione, L.

    1979-01-01

    A computer program to aid in accessing the reliability of fault tolerant avionics systems was developed. A simple mathematical expression was used to evaluate the reliability of any redundant configuration over any interval during which the failure rates and coverage parameters remained unaffected by configuration changes. Provision was made for convolving such expressions in order to evaluate the reliability of a dual mode system. A coverage model was also developed to determine the various relevant coverage coefficients as a function of the available hardware and software fault detector characteristics, and subsequent isolation and recovery delay statistics.

  13. Redesign of the System for Evaluation of Teaching Qualities in Anesthesiology Residency Training (SETQ Smart).

    PubMed

    Lombarts, Kiki M J M H; Ferguson, Andrew; Hollmann, Markus W; Malling, Bente; Arah, Onyebuchi A

    2016-11-01

    Given the increasing international recognition of clinical teaching as a competency and regulation of residency training, evaluation of anesthesiology faculty teaching is needed. The System for Evaluating Teaching Qualities (SETQ) Smart questionnaires were developed for assessing teaching performance of faculty in residency training programs in different countries. This study investigated (1) the structure, (2) the psychometric qualities of the new tools, and (3) the number of residents' evaluations needed per anesthesiology faculty to use the instruments reliably. Two SETQ Smart questionnaires-for faculty self-evaluation and for resident evaluation of faculty-were developed. A multicenter survey was conducted among 399 anesthesiology faculty and 430 residents in six countries. Statistical analyses included exploratory factor analysis, reliability analysis using Cronbach α, item-total scale correlations, interscale correlations, comparison of composite scales to global ratings, and generalizability analysis to assess residents' evaluations needed per faculty. In total, 240 residents completed 1,622 evaluations of 247 faculty. The SETQ Smart questionnaires revealed six teaching qualities consisting of 25 items. Cronbach α's were very high (greater than 0.95) for the overall SETQ Smart questionnaires and high (greater than 0.80) for the separate teaching qualities. Interscale correlations were all within the acceptable range of moderate correlation. Overall, questionnaire and scale scores correlated moderately to highly with the global ratings. For reliable feedback to individual faculty, three to five resident evaluations are needed. The first internationally piloted questionnaires for evaluating individual anesthesiology faculty teaching performance can be reliably, validly, and feasibly used for formative purposes in residency training.

  14. The Validity of Reliability Assessments.

    ERIC Educational Resources Information Center

    Basch, Charles E.; Gold, Robert S.

    1985-01-01

    Reliability guides research design and is used as a standard for judging the credibility of findings and inferences. Using data gathered in a school health education curriculum evaluation as an example, possible errors in hypothesis testing are examined. Appropriateness of internal consistency as a measure of reliability is discussed and…

  15. Retest Reliability of the Rosenzweig Picture-Frustration Study and Similar Semiprojective Techniques

    ERIC Educational Resources Information Center

    Rosenzweig, Saul; And Others

    1975-01-01

    The research dealing with the reliability of the Rosenzweig Picture-Frustration Study is surveyed. Analysis of various split-half, and retest procedures are reviewed and their relative effectiveness evaluated. Reliability measures as applied to projective techniques in general are discussed. (Author/DEP)

  16. Education Research: Bias and poor interrater reliability in evaluating the neurology clinical skills examination

    PubMed Central

    Schuh, L A.; London, Z; Neel, R; Brock, C; Kissela, B M.; Schultz, L; Gelb, D J.

    2009-01-01

    Objective: The American Board of Psychiatry and Neurology (ABPN) has recently replaced the traditional, centralized oral examination with the locally administered Neurology Clinical Skills Examination (NEX). The ABPN postulated the experience with the NEX would be similar to the Mini-Clinical Evaluation Exercise, a reliable and valid assessment tool. The reliability and validity of the NEX has not been established. Methods: NEX encounters were videotaped at 4 neurology programs. Local faculty and ABPN examiners graded the encounters using 2 different evaluation forms: an ABPN form and one with a contracted rating scale. Some NEX encounters were purposely failed by residents. Cohen’s kappa and intraclass correlation coefficients (ICC) were calculated for local vs ABPN examiners. Results: Ninety-eight videotaped NEX encounters of 32 residents were evaluated by 20 local faculty evaluators and 18 ABPN examiners. The interrater reliability for a determination of pass vs fail for each encounter was poor (kappa 0.32; 95% confidence interval [CI] = 0.11, 0.53). ICC between local faculty and ABPN examiners for each performance rating on the ABPN NEX form was poor to moderate (ICC range 0.14-0.44), and did not improve with the contracted rating form (ICC range 0.09-0.36). ABPN examiners were more likely than local examiners to fail residents. Conclusions: There is poor interrater reliability between local faculty and American Board of Psychiatry and Neurology examiners. A bias was detected for favorable assessment locally, which is concerning for the validity of the examination. Further study is needed to assess whether training can improve interrater reliability and offset bias. GLOSSARY ABIM = American Board of Internal Medicine; ABPN = American Board of Psychiatry and Neurology; CI = confidence interval; HFH = Henry Ford Hospital; ICC = intraclass correlation coefficients; IM = internal medicine; mini-CEX = Mini-Clinical Evaluation Exercise; NEX = Neurology Clinical Skills Examination; RITE = residency inservice training examination; UC = University of Cincinnati; UM = University of Michigan; USF = University of South Florida. PMID:19605769

  17. Semi-Markov adjunction to the Computer-Aided Markov Evaluator (CAME)

    NASA Technical Reports Server (NTRS)

    Rosch, Gene; Hutchins, Monica A.; Leong, Frank J.; Babcock, Philip S., IV

    1988-01-01

    The rule-based Computer-Aided Markov Evaluator (CAME) program was expanded in its ability to incorporate the effect of fault-handling processes into the construction of a reliability model. The fault-handling processes are modeled as semi-Markov events and CAME constructs and appropriate semi-Markov model. To solve the model, the program outputs it in a form which can be directly solved with the Semi-Markov Unreliability Range Evaluator (SURE) program. As a means of evaluating the alterations made to the CAME program, the program is used to model the reliability of portions of the Integrated Airframe/Propulsion Control System Architecture (IAPSA 2) reference configuration. The reliability predictions are compared with a previous analysis. The results bear out the feasibility of utilizing CAME to generate appropriate semi-Markov models to model fault-handling processes.

  18. Student Practice Evaluation Form-Revised Edition online comment bank: development and reliability analysis.

    PubMed

    Rodger, Sylvia; Turpin, Merrill; Copley, Jodie; Coleman, Allison; Chien, Chi-Wen; Caine, Anne-Maree; Brown, Ted

    2014-08-01

    The reliable evaluation of occupational therapy students completing practice education placements along with provision of appropriate feedback is critical for both students and for universities from a quality assurance perspective. This study describes the development of a comment bank for use with an online version of the Student Practice Evaluation Form-Revised Edition (SPEF-R Online) and investigates its reliability. A preliminary bank of 109 individual comments (based on previous students' placement performance) was developed via five stages. These comments reflected all 11 SPEF-R domains. A purpose-designed online survey was used to examine the reliability of the comment bank. A total of 37 practice educators returned surveys, 31 of which were fully completed. Participants were asked to rate each individual comment using the five-point SPEF-R rating scale. One hundred and two of 109 comments demonstrated satisfactory agreement with their respective default ratings that were determined by the development team. At each domain level, the intra-class correlation coefficients (ranging between 0.86 and 0.96) also demonstrated good to excellent inter-rater reliability. There were only seven items that required rewording prior to inclusion in the final SPEF-R Online comment bank. The development of the SPEF-R Online comment bank offers a source of reliable comments (consistent with the SPEF-R rating scale across different domains) and aims to assist practice educators in providing reliable and timely feedback to students in a user-friendly manner. © 2014 Occupational Therapy Australia.

  19. Test-retest reliability of quantitative sensory testing for mechanical somatosensory and pain modulation assessment of masticatory structures.

    PubMed

    Costa, Y M; Morita-Neto, O; de Araújo-Júnior, E N S; Sampaio, F A; Conti, P C R; Bonjardim, L R

    2017-03-01

    Assessing the reliability of medical measurements is a crucial step towards the elaboration of an applicable clinical instrument. There are few studies that evaluate the reliability of somatosensory assessment and pain modulation of masticatory structures. This study estimated the test-retest reliability, that is over time, of the mechanical somatosensory assessment of anterior temporalis, masseter and temporomandibular joint (TMJ) and the conditioned pain modulation (CPM) using the anterior temporalis as the test site. Twenty healthy women were evaluated in two sessions (1 week apart) by the same examiner. Mechanical detection threshold (MDT), mechanical pain threshold (MPT), wind-up ratio (WUR) and pressure pain threshold (PPT) were assessed on the skin overlying the anterior temporalis, masseter and TMJ of the dominant side. CPM was tested by comparing PPT before and during the hand immersion in a hot water bath. anova and intra-class correlation coefficients (ICCs) were applied to the data (α = 5%). The overall ICCs showed acceptable values for the test-retest reliability of mechanical somatosensory assessment of masticatory structures. The ICC values of 75% of all quantitative sensory measurements were considered fair to excellent (fair = 8·4%, good = 33·3% and excellent = 33·3%). However, the CPM paradigm presented poor reliability (ICC = 0·25). The mechanical somatosensory assessment of the masticatory structures, but not the proposed CPM protocol, can be considered sufficiently reliable over time to evaluate the trigeminal sensory function. © 2016 John Wiley & Sons Ltd.

  20. The reliability and validity of ultrasound to quantify muscles in older adults: a systematic review

    PubMed Central

    Scafoglieri, Aldo; Jager‐Wittenaar, Harriët; Hobbelen, Johannes S.M.; van der Schans, Cees P.

    2017-01-01

    Abstract This review evaluates the reliability and validity of ultrasound to quantify muscles in older adults. The databases PubMed, Cochrane, and Cumulative Index to Nursing and Allied Health Literature were systematically searched for studies. In 17 studies, the reliability (n = 13) and validity (n = 8) of ultrasound to quantify muscles in community‐dwelling older adults (≥60 years) or a clinical population were evaluated. Four out of 13 reliability studies investigated both intra‐rater and inter‐rater reliability. Intraclass correlation coefficient (ICC) scores for reliability ranged from −0.26 to 1.00. The highest ICC scores were found for the vastus lateralis, rectus femoris, upper arm anterior, and the trunk (ICC = 0.72 to 1.000). All included validity studies found ICC scores ranging from 0.92 to 0.999. Two studies describing the validity of ultrasound to predict lean body mass showed good validity as compared with dual‐energy X‐ray absorptiometry (r 2 = 0.92 to 0.96). This systematic review shows that ultrasound is a reliable and valid tool for the assessment of muscle size in older adults. More high‐quality research is required to confirm these findings in both clinical and healthy populations. Furthermore, ultrasound assessment of small muscles needs further evaluation. Ultrasound to predict lean body mass is feasible; however, future research is required to validate prediction equations in older adults with varying function and health. PMID:28703496

  1. Establishing Inter- and Intrarater Reliability for High-Stakes Testing Using Simulation.

    PubMed

    Kardong-Edgren, Suzan; Oermann, Marilyn H; Rizzolo, Mary Anne; Odom-Maryon, Tamara

    This article reports one method to develop a standardized training method to establish the inter- and intrarater reliability of a group of raters for high-stakes testing. Simulation is used increasingly for high-stakes testing, but without research into the development of inter- and intrarater reliability for raters. Eleven raters were trained using a standardized methodology. Raters scored 28 student videos over a six-week period. Raters then rescored all videos over a two-day period to establish both intra- and interrater reliability. One rater demonstrated poor intrarater reliability; a second rater failed all students. Kappa statistics improved from the moderate to substantial agreement range with the exclusion of the two outlier raters' scores. There may be faculty who, for different reasons, should not be included in high-stakes testing evaluations. All faculty are content experts, but not all are expert evaluators.

  2. The application of emulation techniques in the analysis of highly reliable, guidance and control computer systems

    NASA Technical Reports Server (NTRS)

    Migneault, Gerard E.

    1987-01-01

    Emulation techniques can be a solution to a difficulty that arises in the analysis of the reliability of guidance and control computer systems for future commercial aircraft. Described here is the difficulty, the lack of credibility of reliability estimates obtained by analytical modeling techniques. The difficulty is an unavoidable consequence of the following: (1) a reliability requirement so demanding as to make system evaluation by use testing infeasible; (2) a complex system design technique, fault tolerance; (3) system reliability dominated by errors due to flaws in the system definition; and (4) elaborate analytical modeling techniques whose precision outputs are quite sensitive to errors of approximation in their input data. Use of emulation techniques for pseudo-testing systems to evaluate bounds on the parameter values needed for the analytical techniques is then discussed. Finally several examples of the application of emulation techniques are described.

  3. Reliability Analysis of Sealing Structure of Electromechanical System Based on Kriging Model

    NASA Astrophysics Data System (ADS)

    Zhang, F.; Wang, Y. M.; Chen, R. W.; Deng, W. W.; Gao, Y.

    2018-05-01

    The sealing performance of aircraft electromechanical system has a great influence on flight safety, and the reliability of its typical seal structure is analyzed by researcher. In this paper, we regard reciprocating seal structure as a research object to study structural reliability. Having been based on the finite element numerical simulation method, the contact stress between the rubber sealing ring and the cylinder wall is calculated, and the relationship between the contact stress and the pressure of the hydraulic medium is built, and the friction force on different working conditions are compared. Through the co-simulation, the adaptive Kriging model obtained by EFF learning mechanism is used to describe the failure probability of the seal ring, so as to evaluate the reliability of the sealing structure. This article proposes a new idea of numerical evaluation for the reliability analysis of sealing structure, and also provides a theoretical basis for the optimal design of sealing structure.

  4. NEPP DDR Device Reliability FY13 Report

    NASA Technical Reports Server (NTRS)

    Guertin, Steven M.; Armbar, Mehran

    2014-01-01

    This document reports the status of the NEPP Double Data Rate (DDR) Device Reliability effort for FY2013. The task targeted general reliability of > 100 DDR2 devices from Hynix, Samsung, and Micron. Detailed characterization of some devices when stressed by several data storage patterns was studied, targeting ability of the data cells to store the different data patterns without refresh, highlighting the weakest bits. DDR2, Reliability, Data Retention, Temperature Stress, Test System Evaluation, General Reliability, IDD measurements, electronic parts, parts testing, microcircuits

  5. Reliability program requirements for aeronautical and space system contractors

    NASA Technical Reports Server (NTRS)

    1987-01-01

    General reliability program requirements for NASA contracts involving the design, development, fabrication, test, and/or use of aeronautical and space systems including critical ground support equipment are prescribed. The reliability program requirements require (1) thorough planning and effective management of the reliability effort; (2) definition of the major reliability tasks and their place as an integral part of the design and development process; (3) planning and evaluating the reliability of the system and its elements (including effects of software interfaces) through a program of analysis, review, and test; and (4) timely status indication by formal documentation and other reporting to facilitate control of the reliability program.

  6. Reliable computation from contextual correlations

    NASA Astrophysics Data System (ADS)

    Oestereich, André L.; Galvão, Ernesto F.

    2017-12-01

    An operational approach to the study of computation based on correlations considers black boxes with one-bit inputs and outputs, controlled by a limited classical computer capable only of performing sums modulo-two. In this setting, it was shown that noncontextual correlations do not provide any extra computational power, while contextual correlations were found to be necessary for the deterministic evaluation of nonlinear Boolean functions. Here we investigate the requirements for reliable computation in this setting; that is, the evaluation of any Boolean function with success probability bounded away from 1 /2 . We show that bipartite CHSH quantum correlations suffice for reliable computation. We also prove that an arbitrarily small violation of a multipartite Greenberger-Horne-Zeilinger noncontextuality inequality also suffices for reliable computation.

  7. A reliable in vitro fruiting system for armillaria mellea for evaluation of agrobacterium tumefaciens transformation vectors

    USDA-ARS?s Scientific Manuscript database

    Armillaria mellea is a serious pathogen of horticultural and agricultural systems in Europe and North America. The lack of a reliable in vitro fruiting system has hindered research, and necessitated dependence on intermittently available wild-collected basidiospores. Here we describe a reliable, rep...

  8. Reliability and Validity of the Evidence-Based Practice Confidence (EPIC) Scale

    ERIC Educational Resources Information Center

    Salbach, Nancy M.; Jaglal, Susan B.; Williams, Jack I.

    2013-01-01

    Introduction: The reliability, minimal detectable change (MDC), and construct validity of the evidence-based practice confidence (EPIC) scale were evaluated among physical therapists (PTs) in clinical practice. Methods: A longitudinal mail survey was conducted. Internal consistency and test-retest reliability were estimated using Cronbach's alpha…

  9. Videotape Reliability: A Method of Evaluation of a Clinical Performance Examination.

    ERIC Educational Resources Information Center

    And Others; Liu, Philip

    1980-01-01

    A method of statistically analyzing clinical performance examinations for reliability and the application of this method in determining the reliability of two examinations of skill in administering anesthesia are described. Videotaped performances for the Spinal Anesthesia Skill Examination and the Anesthesia Setup and Machine Checkout Examination…

  10. Coefficient Alpha: A Reliability Coefficient for the 21st Century?

    ERIC Educational Resources Information Center

    Yang, Yanyun; Green, Samuel B.

    2011-01-01

    Coefficient alpha is almost universally applied to assess reliability of scales in psychology. We argue that researchers should consider alternatives to coefficient alpha. Our preference is for structural equation modeling (SEM) estimates of reliability because they are informative and allow for an empirical evaluation of the assumptions…

  11. 77 FR 53877 - Commission Information Collection Activities (FERC-715); Comment Request; Extension

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-04

    ...; A detailed description of the transmission planning reliability criteria used to evaluate system... reliability criteria are applied and the steps taken in performing transmission planning studies); and A... reliability criteria using its stated assessment practices. The FERC-715 enables the Commission to use the...

  12. Evaluation of Validity and Reliability for Hierarchical Scales Using Latent Variable Modeling

    ERIC Educational Resources Information Center

    Raykov, Tenko; Marcoulides, George A.

    2012-01-01

    A latent variable modeling method is outlined, which accomplishes estimation of criterion validity and reliability for a multicomponent measuring instrument with hierarchical structure. The approach provides point and interval estimates for the scale criterion validity and reliability coefficients, and can also be used for testing composite or…

  13. The Reliability and Validity of a Scale to Measure Teachers' Attitudes toward Integration in an Australian Context.

    ERIC Educational Resources Information Center

    Roberts, Clare; Pratt, Chris

    1988-01-01

    The study evaluated the psychometric properties of reliability and construct validity of the Attitude Toward Mainstreaming Scale (ATMS) in an Australian context. It was concluded that the scale is both reliable and factorially valid in an Australian context. (Author/DB)

  14. A simulation-based evaluation of methods for inferring linear barriers to gene flow

    Treesearch

    Christopher Blair; Dana E. Weigel; Matthew Balazik; Annika T. H. Keeley; Faith M. Walker; Erin Landguth; Sam Cushman; Melanie Murphy; Lisette Waits; Niko Balkenhol

    2012-01-01

    Different analytical techniques used on the same data set may lead to different conclusions about the existence and strength of genetic structure. Therefore, reliable interpretation of the results from different methods depends on the efficacy and reliability of different statistical methods. In this paper, we evaluated the performance of multiple analytical methods to...

  15. Reliability-Related Issues in the Context of Student Evaluations of Teaching in Higher Education

    ERIC Educational Resources Information Center

    Kalender, Ilker

    2015-01-01

    Student evaluations of teaching (SET) have been the principal instrument to elicit students' opinions in higher education institutions. Many decisions, including high-stake ones, are made based on SET scores reported by students. In this respect, reliability of SET scores is of considerable importance. This paper has an argument that there are…

  16. An Evaluation of Available Models for Estimating the Reliability and Validity of Criterion Referenced Measures.

    ERIC Educational Resources Information Center

    Oakland, Thomas

    New strategies for evaluation criterion referenced measures (CRM) are discussed. These strategies examine the following issues: (1) the use of normed referenced measures (NRM) as CRM and then estimating the reliability and validity of such measures in terms of variance from an arbitrarily specified criterion score, (2) estimation of the…

  17. RADC thermal guide for reliability engineers

    NASA Astrophysics Data System (ADS)

    Morrison, G. N.; Kallis, J. M.; Strattan, L. A.; Jones, I. R.; Lena, A. L.

    1982-06-01

    This guide was developed to provide a reliability engineer, who is not proficient in thermal design and analysis techniques, with the tools for managing and evaluating the thermal design and production of electronic equipment. It defines the requirements and tasks that should be addressed in system equipment specifications and statements of work, and describes how to evaluate performance.

  18. Modifying the Clinical Outcomes in Routine Evaluation Measure for Use with People Who Have a Learning Disability

    ERIC Educational Resources Information Center

    Marshall, Keith; Willoughby-Booth, Simon

    2007-01-01

    There are few reliable self-report measures suitable for people with a learning disability in reporting psychological distress. This study examines the modification of the Clinical Outcomes in Routine Evaluation-Outcome Measure (CORE-OM), exploring its reliability, using two different presentation styles. One style included a sequencing task then…

  19. Evaluating the Impact of the 2017 Solar Eclipse on U.S. Western Interconnection Operations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Veda, Santosh; Zhang, Yingchen; Tan, Jin

    With support from the U.S. Department of Energy (DOE) Solar Energy Technologies Office (SETO), the National Renewable Energy Laboratory (NREL) partnered with Peak Reliability to evaluate the impact of the August 21, 2017 total solar eclipse on the reliability and grid operations in the Western Electricity Coordinating Council (WECC) territory.

  20. Integrated Approach To Design And Analysis Of Systems

    NASA Technical Reports Server (NTRS)

    Patterson-Hine, F. A.; Iverson, David L.

    1993-01-01

    Object-oriented fault-tree representation unifies evaluation of reliability and diagnosis of faults. Programming/fault tree described more fully in "Object-Oriented Algorithm For Evaluation Of Fault Trees" (ARC-12731). Augmented fault tree object contains more information than fault tree object used in quantitative analysis of reliability. Additional information needed to diagnose faults in system represented by fault tree.

  1. Bones, Boys, Bombs and Booze: An Exploratory Study of the Reliability of Marking Dissertations across Disciplines

    ERIC Educational Resources Information Center

    Bettany-Saltikov, Josette; Kilinc, Stephanie; Stow, Karen

    2009-01-01

    The primary aim of this study was to evaluate the reliability of the University's Masters' level (M-level) generic assessment criteria when used by lecturers from different disciplines. A further aim was to evaluate if subject-specific knowledge was essential to marking these dissertations. Four senior lecturers from diverse disciplines…

  2. An Evaluation of Test Speededness in an Assessment for Third-Grade Gifted Students

    ERIC Educational Resources Information Center

    Hailey, Emily; Callahan, Carolyn M.; Azano, Amy; Moon, Tonya R.

    2012-01-01

    Reliability and validity are integral concepts in assessment design. Test speededness, the influence of time constraints on test taker performance, is often an overlooked threat to reliability and validity, especially in classroom-based testing. The purpose of this study is to evaluate the degree of test speededness of classroom-based assessments…

  3. Nutrition and Physical Activity Knowledge Assessment: Development of Questionnaires and Evaluation of Reliability in African American and Latino Children

    ERIC Educational Resources Information Center

    Roberts, Lindsay S.; Sharma, Sushma; Hudes, Mark L.; Fleming, Sharon E.

    2012-01-01

    Background: African-American and Latino children living in neighborhoods with a low-socioeconomic index are more at risk of obesity-associated metabolic disease than their higher socioeconomic index and/or white peers. Currently, consistent and reliable questionnaires to evaluate nutrition and physical activity knowledge in these children are…

  4. An evaluation of the reliability of muscle fiber cross-sectional area and fiber number measurements in rat skeletal muscle

    USDA-ARS?s Scientific Manuscript database

    Background: The reliability of estimating muscle fiber cross-sectional area (measure of muscle fiber size) and fiber number from only a subset of fibers in rat hindlimb muscle cross-sections has not been systematically evaluated. This study examined the variability in mean estimates of fiber cross-s...

  5. Evaluating North American Electric Grid Reliability Using the Barabasi-Albert Network Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chassin, David P.; Posse, Christian

    2005-09-15

    The reliability of electric transmission systems is examined using a scale-free model of network topology and failure propagation. The topologies of the North American eastern and western electric grids are analyzed to estimate their reliability based on the Barabási-Albert network model. A commonly used power system reliability index is computed using a simple failure propagation model. The results are compared to the values of power system reliability indices previously obtained using other methods and they suggest that scale-free network models are usable to estimate aggregate electric grid reliability.

  6. Evaluating North American Electric Grid Reliability Using the Barabasi-Albert Network Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chassin, David P.; Posse, Christian

    2005-09-15

    The reliability of electric transmission systems is examined using a scale-free model of network topology and failure propagation. The topologies of the North American eastern and western electric grids are analyzed to estimate their reliability based on the Barabasi-Albert network model. A commonly used power system reliability index is computed using a simple failure propagation model. The results are compared to the values of power system reliability indices previously obtained using standard power engineering methods, and they suggest that scale-free network models are usable to estimate aggregate electric grid reliability.

  7. Development of the evaluation instrument use CIPP on the implementation of project assessment topic optik

    NASA Astrophysics Data System (ADS)

    Asfaroh, Jati Aurum; Rosana, Dadan; Supahar

    2017-08-01

    This research aims to develop an evaluation instrument models CIPP valid and reliable as well as determine the feasibility and practicality of an evaluation instrument models CIPP. An evaluation instrument models CIPP to evaluate the implementation of the project assessment topic optik to measure problem-solving skills of junior high school class VIII in the Yogyakarta region. This research is a model of development that uses 4-D. Subject of product trials are students in class VIII SMP N 1 Galur and SMP N 1 Sleman. Data collection techniques in this research using non-test techniques include interviews, questionnaires and observations. Validity in this research was analyzed using V'Aikens. Reliability analyzed using ICC. This research uses 7 raters are derived from two lecturers expert (expert judgment), two practitioners (science teacher) and three colleagues. The results of this research is the evaluation's instrument model of CIPP is used to evaluate the implementation of the implementation of the project assessment instruments. The validity result of evaluation instrument have V'Aikens values between 0.86 to 1, which means a valid and 0.836 reliability values into categories so well that it has been worth used as an evaluation instrument.

  8. Evaluating abdominal core muscle fatigue: Assessment of the validity and reliability of the prone bridging test.

    PubMed

    De Blaiser, C; De Ridder, R; Willems, T; Danneels, L; Vanden Bossche, L; Palmans, T; Roosen, P

    2018-02-01

    The aims of this study were to research the amplitude and median frequency characteristics of selected abdominal, back, and hip muscles of healthy subjects during a prone bridging endurance test, based on surface electromyography (sEMG), (a) to determine if the prone bridging test is a valid field test to measure abdominal muscle fatigue, and (b) to evaluate if the current method of administrating the prone bridging test is reliable. Thirty healthy subjects participated in this experiment. The sEMG activity of seven abdominal, back, and hip muscles was bilaterally measured. Normalized median frequencies were computed from the EMG power spectra. The prone bridging tests were repeated on separate days to evaluate inter and intratester reliability. Significant differences in normalized median frequency slope (NMF slope ) values between several abdominal, back, and hip muscles could be demonstrated. Moderate-to-high correlation coefficients were shown between NMF slope values and endurance time. Multiple backward linear regression revealed that the test endurance time could only be significantly predicted by the NMF slope of the rectus abdominis. Statistical analysis showed excellent reliability (ICC=0.87-0.89). The findings of this study support the validity and reliability of the prone bridging test for evaluating abdominal muscle fatigue. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Reliability of Instruments Measuring At-Risk and Problem Gambling Among Young Individuals: A Systematic Review Covering Years 2009-2015.

    PubMed

    Edgren, Robert; Castrén, Sari; Mäkelä, Marjukka; Pörtfors, Pia; Alho, Hannu; Salonen, Anne H

    2016-06-01

    This review aims to clarify which instruments measuring at-risk and problem gambling (ARPG) among youth are reliable and valid in light of reported estimates of internal consistency, classification accuracy, and psychometric properties. A systematic search was conducted in PubMed, Medline, and PsycInfo covering the years 2009-2015. In total, 50 original research articles fulfilled the inclusion criteria: target age under 29 years, using an instrument designed for youth, and reporting a reliability estimate. Articles were evaluated with the revised Quality Assessment of Diagnostic Accuracy Studies tool. Reliability estimates were reported for five ARPG instruments. Most studies (66%) evaluated the South Oaks Gambling Screen Revised for Adolescents. The Gambling Addictive Behavior Scale for Adolescents was the only novel instrument. In general, the evaluation of instrument reliability was superficial. Despite its rare use, the Canadian Adolescent Gambling Inventory (CAGI) had a strong theoretical and methodological base. The Gambling Addictive Behavior Scale for Adolescents and the CAGI were the only instruments originally developed for youth. All studies, except the CAGI study, were population based. ARPG instruments for youth have not been rigorously evaluated yet. Further research is needed especially concerning instruments designed for clinical use. Copyright © 2016 The Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  10. Reliability of the penetration aspiration scale with flexible endoscopic evaluation of swallowing.

    PubMed

    Butler, Susan G; Markley, Lisa; Sanders, Brian; Stuart, Andrew

    2015-06-01

    The Penetration Aspiration Scale (PAS), although designed for videofluoroscopy, has been utilized with flexible endoscopic evaluation of swallowing (FEES) in both research and clinical practice. The purpose of this investigation was to determine inter- and intrarater reliability of the PAS with FEES as a function of clinician FEES experience and retest interval. Three groups of 3 clinicians (N=9) with varying FEES experience (beginning, intermediate, and advanced) assigned PAS scores to 35 swallows. Initial ratings were repeated following short-term (ie, 1 day) and long-term (ie, 1 week) retest intervals. Intraclass correlation coefficients were calculated to assess interrater reliability on the first rating for each group. The coefficients were .91, .82, and .89 for the beginning, intermediate, and advanced clinicians, respectively. Overall interrater reliability across all 9 clinicians, irrespective of experience, was .85. Intraclass correlation coefficients were also calculated to assess intrarater reliability. The intrarater reliability for short- and long-term ratings was .90, .94, and .96 and .96, .97, and .94 for the beginning, intermediate, and advanced clinicians, respectively. Overall intrarater reliability across all 9 clinicians and all 3 ratings was .94. Excellent inter- and intrarater reliability was evidenced with the application of the PAS for FEES regardless of clinician experience and retest interval. © The Author(s) 2015.

  11. Measuring acuity of the approximate number system reliably and validly: the evaluation of an adaptive test procedure

    PubMed Central

    Lindskog, Marcus; Winman, Anders; Juslin, Peter; Poom, Leo

    2013-01-01

    Two studies investigated the reliability and predictive validity of commonly used measures and models of Approximate Number System acuity (ANS). Study 1 investigated reliability by both an empirical approach and a simulation of maximum obtainable reliability under ideal conditions. Results showed that common measures of the Weber fraction (w) are reliable only when using a substantial number of trials, even under ideal conditions. Study 2 compared different purported measures of ANS acuity as for convergent and predictive validity in a within-subjects design and evaluated an adaptive test using the ZEST algorithm. Results showed that the adaptive measure can reduce the number of trials needed to reach acceptable reliability. Only direct tests with non-symbolic numerosity discriminations of stimuli presented simultaneously were related to arithmetic fluency. This correlation remained when controlling for general cognitive ability and perceptual speed. Further, the purported indirect measure of ANS acuity in terms of the Numeric Distance Effect (NDE) was not reliable and showed no sign of predictive validity. The non-symbolic NDE for reaction time was significantly related to direct w estimates in a direction contrary to the expected. Easier stimuli were found to be more reliable, but only harder (7:8 ratio) stimuli contributed to predictive validity. PMID:23964256

  12. Sensitivity, reliability and the effects of diurnal variation on a test battery of field usable upper limb fatigue measures.

    PubMed

    Yung, Marcus; Wells, Richard P

    2017-07-01

    Fatigue has been linked to deficits in production quality and productivity and, if of long duration, work-related musculoskeletal disorders. It may thus be a useful risk indicator and design and evaluation tool. However, there is limited information on the test-retest reliability, the sensitivity and the effects of diurnal fluctuation on field usable fatigue measures. This study reports on an evaluation of 11 measurement tools and their 14 parameters. Eight measures were found to have test-retest ICC values greater than 0.8. Four measures were particularly responsive during an intermittent fatiguing condition. However, two responsive measures demonstrated rhythmic behaviour, with significant time effects from 08:00 to mid-afternoon and early evening. Action tremor, muscle mechanomyography and perceived fatigue were found to be most reliable and most responsive; but additional analytical considerations might be required when interpreting daylong responses of MMG and action tremor. Practitioner Summary: This paper presents findings from test-retest and daylong reliability and responsiveness evaluations of 11 fatigue measures. This paper suggests that action tremor, muscle mechanomyography and perceived fatigue were most reliable and most responsive. However, mechanomyography and action tremor may be susceptible to diurnal changes.

  13. [Modification and evaluation of assessment of 
medication literacy].

    PubMed

    Zheng, Feng; Zhong, Zhuqing; Ding, Siqing; Luo, Aijing; Liu, Zina

    2016-11-28

    To translate and revise the Medication Literacy Assessment in English (MedLitRxSE-English) and evaluate its validity and reliability.
 Methods: We introduced MedLitRxSE-English from abroad. According to the principles of Brislin and culture adjustment, we revised it as a Chinese edition. Using random sampling method, from Oct, 2014 to Jan, 2015, 461 non-hospitalized patients from the outpatient departments of the top three hospitals in Changsha city were investigated. The reliability and validity of the scale was tested.
 Results: The test-retest reliability of the Chinese version for medication literacy scale was 0.885; the split reliability was 0.840; K-R was 0.820; the correlations between the assessment of medication literacy and the corresponding items were 0.427-0.587; the confirmatory factor analysis revealed overall good fit. Root mean square error of approximation (RMSEA), χ2/df, goodness of fit index (GFI) and comparative fit index (CFI) was 0.08, 3.06, 0.91 and 0.94, respectively. 
 Conclusion: The Chinese version for the assessment of medication literacy is in good reliability and validity, and it can be used to evaluate the medication literacy in our country.

  14. Inter-Observer Reliability of DSM-5 Substance Use Disorders*

    PubMed Central

    Denis, Cécile M.; Gelernter, Joel; Hart, Amy B.; Kranzler, Henry R.

    2015-01-01

    Aims Although studies have examined the impact of changes made in DSM-5 on the estimated prevalence of substance use disorder (SUD) diagnoses, there is limited evidence of the reliability of DSM-5 SUDs. We evaluated the inter-observer reliability of four DSM-5 SUDs in a sample in which we had previously evaluated the reliability of DSM-IV diagnoses, allowing us to compare the two systems. Methods Two different interviewers each assessed 173 subjects over a 2-week period using the Semi-Structured Assessment for Drug Dependence and Alcoholism (SSADDA). Using the percent agreement and kappa (κ) coefficient, we examined the reliability of DSM-5 lifetime alcohol, opioid, cocaine, and cannabis use disorders, which we compared to that of SSADDA-derived DSM-IV SUD diagnoses. We also assessed the effect of additional lifetime SUD and lifetime mood or anxiety disorder diagnoses on the reliability of the DSM-5 SUD diagnoses. Results Reliability was good to excellent for the four disorders, with κ values ranging from 0.65 to 0.94. Agreement was consistently lower for SUDs of mild severity than for moderate or severe disorders. DSM-5 SUD diagnoses showed greater reliability than DSM-IV diagnoses of abuse or dependence or dependence only. Co-occurring SUD and lifetime mood or anxiety disorders exerted a modest effect on the reliability of the DSM-5 SUD diagnoses. Conclusions For alcohol, opioid, cocaine and cannabis use disorders, DSM-5 criteria and diagnoses are at least as reliable as those of DSM-IV. PMID:26048641

  15. Reliability of CGA/LGA/HDI Package Board/Assembly (Revision A)

    NASA Technical Reports Server (NTRS)

    Ghaffarian, Reza

    2013-01-01

    This follow-up report presents reliability test results conducted by thermal cycling of five CGA assemblies evaluated under two extreme cycle profiles, representative of use for high-reliability applications. The thermal cycles ranged from a low temperature of 55 C to maximum temperatures of either 100 C or 125 C with slow ramp-up rate (3 C/min) and dwell times of about 15 minutes at the two extremes. Optical photomicrographs that illustrate key inspection findings of up to 200 thermal cycles are presented. Other information presented include an evaluation of the integrity of capacitors on CGA substrate after thermal cycling as well as process evaluation for direct assembly of an LGA onto PCB. The qualification guidelines, which are based on the test results for CGA/LGA/HDI packages and board assemblies, will facilitate NASA projects' use of very dense and newly available FPGA area array packages with known reliably and mitigation risks, allowing greater processing power in a smaller board footprint and lower system weight.

  16. The Internal Reliability of Family Crisis Oriented Personal Evaluation Scale (F-COPES) in Malay version among caregivers of individual with learning disabilities.

    PubMed

    Alwi, N; Harun, D; Omar, B; Ahmad, M; Zagan, M; Leonard, J H

    2015-01-01

    Caregivers face challenges to adapt while handling individual with learning disabilities (LD). The Family Crisis Oriented Personal Evaluation Scale (F-COPES) is a widely used instrument to measure coping strategies among caregivers. The current study performed cross cultural translation of F-COPES in Malay language. This study aims to examine the reliability by testing internal consistency of Malay version of F-COPES which is developed through back to back translation method from original English version. The Malay version of F-COPES was administered among 30 caregivers. The reliability of F-COPES in Malay version is good with Cronbach's alpha coefficient value of 0.79. The internal consistency on sub domains of F-COPES such as reframing, acquiring social support and seeking spiritual support also acceptable with Cronbach's alpha values 0.67, 0.74, and 0.80, respectively. The Malay version of F-COPES is a reliable tool to evaluate the coping strategies adopted by the caregivers of individual with LD.

  17. TEST-RETEST RELIABILITY OF THE CLOSED KINETIC CHAIN UPPER EXTREMITY STABILITY TEST (CKCUEST) IN ADOLESCENTS: RELIABILITY OF CKCUEST IN ADOLESCENTS.

    PubMed

    de Oliveira, Valéria M A; Pitangui, Ana C R; Nascimento, Vinícius Y S; da Silva, Hítalo A; Dos Passos, Muana H P; de Araújo, Rodrigo C

    2017-02-01

    The Closed Kinetic Chain Upper Extremity Stability Test (CKCUEST) has been proposed as an option to assess upper limb function and stability; however, there are few studies that support the use of this test in adolescents. The purpose of the present study was to investigate the intersession reliability and agreement of three CKCUEST scores in adolescents and establish clinimetric values for this test. Test-retest reliability. Twenty-five healthy adolescents of both sexes were evaluated. The subjects performed two CKCUEST with an interval of one week between the tests. An intraclass correlation coefficient (ICC 3,3 ) two-way mixed model with a 95% interval of confidence was utilized to determine intersession reliability. A Bland-Altman graph was plotted to analyze the agreement between assessments. The presence of systematic error was evaluated by a one-sample t test. The difference between the evaluation and reevaluation was observed using a paired-sample t test. The level of significance was set at 0.05. Standard error of measurements and minimum detectable changes were calculated. The intersession reliability of the average touches score, normalized score, and power score were 0.68, 0.68 and 0.87, the standard error of measurement were 2.17, 1.35 and 6.49, and the minimal detectable change was 6.01, 3.74 and 17.98, respectively. The presence of systematic error (p < 0.014), the significant difference between the measurements (p < 0.05), and the analysis of the Bland-Altman graph infer that CKCUEST is a discordant test with moderate to excellent reliability when used with adolescents. The CKCUEST is a measurement with moderate to excellent reliability for adolescents. 2b.

  18. The interrater and test-retest reliability of the Home Falls and Accidents Screening Tool (HOME FAST) in Malaysia: Using raters with a range of professional backgrounds.

    PubMed

    Romli, Muhammad Hibatullah; Mackenzie, Lynette; Lovarini, Meryl; Tan, Maw Pin; Clemson, Lindy

    2017-06-01

    Falls can be a devastating issue for older people living in the community, including those living in Malaysia. Health professionals and community members have a responsibility to ensure that older people have a safe home environment to reduce the risk of falls. Using a standardised screening tool is beneficial to intervene early with this group. The Home Falls and Accidents Screening Tool (HOME FAST) should be considered for this purpose; however, its use in Malaysia has not been studied. Therefore, the aim of this study was to evaluate the interrater and test-retest reliability of the HOME FAST with multiple professionals in the Malaysian context. A cross-sectional design was used to evaluate interrater reliability where the HOME FAST was used simultaneously in the homes of older people by 2 raters and a prospective design was used to evaluate test-retest reliability with a separate group of older people at different times in their homes. Both studies took place in an urban area of Kuala Lumpur. Professionals from 9 professional backgrounds participated as raters in this study, and a group of 51 community older people were recruited for the interrater reliability study and another group of 30 for the test-retest reliability study. The overall agreement was moderate for interrater reliability and good for test-retest reliability. The HOME FAST was consistently rated by different professionals, and no bias was found among the multiple raters. The HOME FAST can be used with confidence by a variety of professionals across different settings. The HOME FAST can become a universal tool to screen for home hazards related to falls. © 2017 John Wiley & Sons, Ltd.

  19. Test-retest reliability of resting-state magnetoencephalography power in sensor and source space.

    PubMed

    Martín-Buro, María Carmen; Garcés, Pilar; Maestú, Fernando

    2016-01-01

    Several studies have reported changes in spontaneous brain rhythms that could be used as clinical biomarkers or in the evaluation of neuropsychological and drug treatments in longitudinal studies using magnetoencephalography (MEG). There is an increasing necessity to use these measures in early diagnosis and pathology progression; however, there is a lack of studies addressing how reliable they are. Here, we provide the first test-retest reliability estimate of MEG power in resting-state at sensor and source space. In this study, we recorded 3 sessions of resting-state MEG activity from 24 healthy subjects with an interval of a week between each session. Power values were estimated at sensor and source space with beamforming for classical frequency bands: delta (2-4 Hz), theta (4-8 Hz), alpha (8-13 Hz), low beta (13-20 Hz), high beta (20-30 Hz), and gamma (30-45 Hz). Then, test-retest reliability was evaluated using the intraclass correlation coefficient (ICC). We also evaluated the relation between source power and the within-subject variability. In general, ICC of theta, alpha, and low beta power was fairly high (ICC > 0.6) while in delta and gamma power was lower. In source space, fronto-posterior alpha, frontal beta, and medial temporal theta showed the most reliable profiles. Signal-to-noise ratio could be partially responsible for reliability as low signal intensity resulted in high within-subject variability, but also the inherent nature of some brain rhythms in resting-state might be driving these reliability patterns. In conclusion, our results described the reliability of MEG power estimates in each frequency band, which could be considered in disease characterization or clinical trials. © 2015 Wiley Periodicals, Inc.

  20. How to assess and compare inter-rater reliability, agreement and correlation of ratings: an exemplary analysis of mother-father and parent-teacher expressive vocabulary rating pairs

    PubMed Central

    Stolarova, Margarita; Wolf, Corinna; Rinker, Tanja; Brielmann, Aenne

    2014-01-01

    This report has two main purposes. First, we combine well-known analytical approaches to conduct a comprehensive assessment of agreement and correlation of rating-pairs and to dis-entangle these often confused concepts, providing a best-practice example on concrete data and a tutorial for future reference. Second, we explore whether a screening questionnaire developed for use with parents can be reliably employed with daycare teachers when assessing early expressive vocabulary. A total of 53 vocabulary rating pairs (34 parent–teacher and 19 mother–father pairs) collected for two-year-old children (12 bilingual) are evaluated. First, inter-rater reliability both within and across subgroups is assessed using the intra-class correlation coefficient (ICC). Next, based on this analysis of reliability and on the test-retest reliability of the employed tool, inter-rater agreement is analyzed, magnitude and direction of rating differences are considered. Finally, Pearson correlation coefficients of standardized vocabulary scores are calculated and compared across subgroups. The results underline the necessity to distinguish between reliability measures, agreement and correlation. They also demonstrate the impact of the employed reliability on agreement evaluations. This study provides evidence that parent–teacher ratings of children's early vocabulary can achieve agreement and correlation comparable to those of mother–father ratings on the assessed vocabulary scale. Bilingualism of the evaluated child decreased the likelihood of raters' agreement. We conclude that future reports of agreement, correlation and reliability of ratings will benefit from better definition of terms and stricter methodological approaches. The methodological tutorial provided here holds the potential to increase comparability across empirical reports and can help improve research practices and knowledge transfer to educational and therapeutic settings. PMID:24994985

  1. Research on Novel Algorithms for Smart Grid Reliability Assessment and Economic Dispatch

    NASA Astrophysics Data System (ADS)

    Luo, Wenjin

    In this dissertation, several studies of electric power system reliability and economy assessment methods are presented. To be more precise, several algorithms in evaluating power system reliability and economy are studied. Furthermore, two novel algorithms are applied to this field and their simulation results are compared with conventional results. As the electrical power system develops towards extra high voltage, remote distance, large capacity and regional networking, the application of a number of new technique equipments and the electric market system have be gradually established, and the results caused by power cut has become more and more serious. The electrical power system needs the highest possible reliability due to its complication and security. In this dissertation the Boolean logic Driven Markov Process (BDMP) method is studied and applied to evaluate power system reliability. This approach has several benefits. It allows complex dynamic models to be defined, while maintaining its easy readability as conventional methods. This method has been applied to evaluate IEEE reliability test system. The simulation results obtained are close to IEEE experimental data which means that it could be used for future study of the system reliability. Besides reliability, modern power system is expected to be more economic. This dissertation presents a novel evolutionary algorithm named as quantum evolutionary membrane algorithm (QEPS), which combines the concept and theory of quantum-inspired evolutionary algorithm and membrane computation, to solve the economic dispatch problem in renewable power system with on land and offshore wind farms. The case derived from real data is used for simulation tests. Another conventional evolutionary algorithm is also used to solve the same problem for comparison. The experimental results show that the proposed method is quick and accurate to obtain the optimal solution which is the minimum cost for electricity supplied by wind farm system.

  2. Can we have an overall osteoarthritis severity score for the patellofemoral joint using magnetic resonance imaging? Reliability and validity.

    PubMed

    Kobayashi, Sarah; Peduto, Anthony; Simic, Milena; Fransen, Marlene; Refshauge, Kathryn; Mah, Jean; Pappas, Evangelos

    2018-04-01

    This work aimed to assess inter-rater reliability and agreement of a magnetic resonance imaging (MRI)-based Kellgren and Lawrence (K&L) grading for patellofemoral joint osteoarthritis (OA) and to validate it against the MRI Osteoarthritis Knee Score (MOAKS). MRI scans from people aged 45 to 75 years with chronic knee pain participating in a randomised clinical trial evaluating dietary supplements were utilised. Fifty participants were randomly selected and scored using the MRI-based K&L grading using axial and sagittal MRI scans. Raters conducted inter-rater reliability, blinded to clinical information, radiology reports and other rater results. Intra- and inter-rater reliability and agreement were evaluated using the intra-class correlation coefficient (ICC) and Cohen's weighted kappa. There was a 2-week interval between the first and second readings for intra-rater reliability. Validity was assessed using the MOAKS and evaluated using Spearman's correlation coefficient. Intra-rater reliability of the K&L system was excellent: ICC 0.91 (95% CI 0.82-0.95); weighted kappa (ĸ = 0.69). Inter-rater reliability was high (ICC 0.88; 95% CI 0.79-0.93), while agreement between raters was moderate (ĸ = 0.49-0.57). Validity analysis demonstrated a strong correlation between the total MOAKS features score and the K&L grading system (ρ = 0.62-0.67) but weak correlations when compared with individual MOAKS features (ρ = 0.19-0.61). The high reliability and good agreement show consistency in grading the severity of patellofemoral OA with the MRI-based K&L score. Our validity results suggest that the scale may be useful, particularly in the clinical environment. Future research should validate this method against clinical findings.

  3. Functional gait assessment and balance evaluation system test: reliability, validity, sensitivity, and specificity for identifying individuals with Parkinson disease who fall.

    PubMed

    Leddy, Abigail L; Crowner, Beth E; Earhart, Gammon M

    2011-01-01

    Gait impairments, balance impairments, and falls are prevalent in individuals with Parkinson disease (PD). Although the Berg Balance Scale (BBS) can be considered the reference standard for the determination of fall risk, it has a noted ceiling effect. Development of ceiling-free measures that can assess balance and are good at discriminating "fallers" from "nonfallers" is needed. The purpose of this study was to compare the Functional Gait Assessment (FGA) and the Balance Evaluation Systems Test (BESTest) with the BBS among individuals with PD and evaluate the tests' reliability, validity, and discriminatory sensitivity and specificity for fallers versus nonfallers. This was an observational study of community-dwelling individuals with idiopathic PD. The BBS, FGA, and BESTest were administered to 80 individuals with PD. Interrater reliability (n=15) was assessed by 3 raters. Test-retest reliability was based on 2 tests of participants (n=24), 2 weeks apart. Intraclass correlation coefficients (2,1) were used to calculate reliability, and Spearman correlation coefficients were used to assess validity. Cutoff points, sensitivity, and specificity were based on receiver operating characteristic plots. Test-retest reliability was .80 for the BBS, .91 for the FGA, and .88 for the BESTest. Interrater reliability was greater than .93 for all 3 tests. The FGA and BESTest were correlated with the BBS (r=.78 and r=.87, respectively). Cutoff scores to identify fallers were 47/56 for the BBS, 15/30 for the FGA, and 69% for the BESTest. The overall accuracy (area under the curve) for the BBS, FGA, and BESTest was .79, .80, and .85, respectively. Fall reports were retrospective. Both the FGA and the BESTest have reliability and validity for assessing balance in individuals with PD. The BESTest is most sensitive for identifying fallers.

  4. Validity and Reliability of the Clinical Competency Evaluation Instrument for Use among Physiotherapy Students: Pilot study.

    PubMed

    Muhamad, Zailani; Ramli, Ayiesah; Amat, Salleh

    2015-05-01

    The aim of this study was to determine the content validity, internal consistency, test-retest reliability and inter-rater reliability of the Clinical Competency Evaluation Instrument (CCEVI) in assessing the clinical performance of physiotherapy students. This study was carried out between June and September 2013 at University Kebangsaan Malaysia (UKM), Kuala Lumpur, Malaysia. A panel of 10 experts were identified to establish content validity by evaluating and rating each of the items used in the CCEVI with regards to their relevance in measuring students' clinical competency. A total of 50 UKM undergraduate physiotherapy students were assessed throughout their clinical placement to determine the construct validity of these items. The instrument's reliability was determined through a cross-sectional study involving a clinical performance assessment of 14 final-year undergraduate physiotherapy students. The content validity index of the entire CCEVI was 0.91, while the proportion of agreement on the content validity indices ranged from 0.83-1.00. The CCEVI construct validity was established with factor loading of ≥0.6, while internal consistency (Cronbach's alpha) overall was 0.97. Test-retest reliability of the CCEVI was confirmed with a Pearson's correlation range of 0.91-0.97 and an intraclass coefficient correlation range of 0.95-0.98. Inter-rater reliability of the CCEVI domains ranged from 0.59 to 0.97 on initial and subsequent assessments. This pilot study confirmed the content validity of the CCEVI. It showed high internal consistency, thereby providing evidence that the CCEVI has moderate to excellent inter-rater reliability. However, additional refinement in the wording of the CCEVI items, particularly in the domains of safety and documentation, is recommended to further improve the validity and reliability of the instrument.

  5. The validity and reliability of the Thai version of the Kujala score for patients with patellofemoral pain syndrome.

    PubMed

    Apivatgaroon, Adinun; Angthong, Chayanin; Sanguanjit, Prakasit; Chernchujit, Bancha

    2016-10-01

    To develop a Thai version of the Kujala score and show the evaluation of the validity and reliability of the score. The Thai version of the Kujala score was developed using the forward-backward translation protocol. The 49 PFPS patients answered the Thai version of questionnaires including the Kujala score, Short Form-36 (SF-36) and International Knee Documentation Committee (IKDC) Subjective Knee Form. The validity between the scores has been tested. The reliability was assessed using test-retest reliability and internal consistency. The Thai version of the Kujala score showed a good correlation with Thai IKDC Subjective Knee Form (Pearson's correlation coefficient; r = 0.74: p < 0.01) and moderate correlation with the Thai SF-36 subscales of physical component summary, total score and role physical (r = 0.586, 0.571 and 0.524, respectively: p < 0.01). The test-retest reliability was excellent with an intra-class correlation coefficient of 0.908 (p < 0.001; 95% CI [0.842-0.947]). The internal consistency was strong with Cronbach's alpha of 0.952 (p < 0.001). No floor and ceiling effects were observed. The Thai version of the Kujala score has shown good validity and reliability. This score can be effectively used for evaluating Thai patients with patellofemoral pain syndrome. Implications for Rehabilitation The Kujala score is a self-administered questionnaire for patients with patellofemoral pain syndrome (PFPS). The validity and reliability of the Thai version of Kujala are compatible with other versions (Turkish, Chinese and Persian version). The Thai version of Kujala has been shown to have validity and reliability in Thai PFPS patients and can be used for clinical evaluation and also in the research work.

  6. Validity and Reliability of a Virtual Reality Game in Evaluating the Projected Frontal Plane Knee Angle When Landing From a Drop Vertical Jump.

    PubMed

    Mills, Kathryn; Idris, Aula; Pham, Thu-An; Porte, John; Wiggins, Mark; Kavakli, Manolya

    2017-12-18

    To determine the validity and reliability of the peak frontal plane knee angle evaluated by a virtual reality (VR) netball game when landing from a drop vertical jump (DVJ). Laboratory Methods: Forty participants performed 3 DVJs evaluated by 3-dimensional (3D) motion analysis and 3 DVJs evaluated by the VR game. Limits of agreement for the peak projected frontal plane knee angle and peak knee abduction were determined. Participants were given a consensus category of "Above threshold" or "Below threshold" based on a pre-specified threshold angle of 9˚ during landing. Classification agreement was determined using kappa coefficient and accuracy was determined using specificity and sensitivity. Ten participants returned 1-week later to determine intra-rater reliability, standard error of the measure and typical error. The mean difference in detected frontal plane knee angle was 3.39˚ (1.03˚, 5.74˚). Limits of agreement were -10.27˚ (-14.36˚, -6.19˚) to 17.05˚ (12.97˚, 21.14˚). Substantial agreement, specificity and sensitivity were observed for the threshold classification (ĸ = 0.66, [0.42, 0.88] specificity= 0.96 [0.78, 1.0], sensitivity= 0.75 [0.43, 0.95]). The game exhibited acceptable reliability over time (ICC (3,1) = 0.844) and error was approximately 2˚. The VR game reliably evaluated a projected frontal plane knee angle. While the knee angle detected by the VR game is strongly related peak knee abduction, the accuracy of detecting the exact angle was limited. A threshold approach may be a more accurate approach for gaming technology to evaluate frontal plane knee angles when landing from a jump.

  7. Reliability and Validity of the Hip Stability Isometric Test (HipSIT): A New Method to Assess Hip Posterolateral Muscle Strength.

    PubMed

    Almeida, Gabriel Peixoto Leão; das Neves Rodrigues, Helena Larissa; de Freitas, Bruno Wesley; de Paula Lima, Pedro Olavo

    2017-12-01

    Study Design Cross-sectional study. Background The Hip Stability Isometric Test (HipSIT) evaluates the strength of the hip posterolateral stabilizers in a position that favors greater activation of the gluteus maximus and gluteus medius and lower activation of the tensor fascia lata. Objectives To check the validity and reliability of the HipSIT and to evaluate the HipSIT in women with patellofemoral pain (PFP). Methods The HipSIT was evaluated with a handheld dynamometer. During testing, the participants were sidelying, with their legs positioned at 45° of hip flexion and 90° of knee flexion. Participants were instructed to raise the knee of the upper leg while keeping the upper and lower heels in contact. To establish reliability and validity, 49 women were tested with the HipSIT by 2 different evaluators on day 1, and then again 7 days later. The strength of the hip extensors, abductors, and external rotators was also evaluated. Twenty women with unilateral PFP were also evaluated. Results The HipSIT has excellent intrarater and interrater reliability. The standard error of measurement was 0.01 kgf/kg, and the minimal detectable change was 0.036 kgf/kg. The HipSIT showed good validity in isolated hip abduction, external rotation, and extension (P<.01). Women with PFP showed a 10% deficit in the HipSIT results for the symptomatic limb (P = .01). Conclusion The HipSIT showed excellent interrater and intrarater reliability, moderate to good validity in women, and was able to identify strength deficits in women with PFP. J Orthop Sports Phys Ther 2017;47(12):906-913. Epub 9 Oct 2017. doi:10.2519/jospt.2017.7274.

  8. Combining web-based tools for transparent evaluation of data for risk assessment: developmental effects of bisphenol A on the mammary gland as a case study.

    PubMed

    Molander, Linda; Hanberg, Annika; Rudén, Christina; Ågerstrand, Marlene; Beronius, Anna

    2017-03-01

    Different tools have been developed that facilitate systematic and transparent evaluation and handling of toxicity data in the risk assessment process. The present paper sets out to explore the combined use of two web-based tools for study evaluation and identification of reliable data relevant to health risk assessment. For this purpose, a case study was performed using in vivo toxicity studies investigating low-dose effects of bisphenol A on mammary gland development. The reliability of the mammary gland studies was evaluated using the Science in Risk Assessment and Policy (SciRAP) criteria for toxicity studies. The Health Assessment Workspace Collaborative (HAWC) was used for characterizing and visualizing the mammary gland data in terms of type of effects investigated and reported, and the distribution of these effects within the dose interval. It was then investigated whether there was any relationship between study reliability and the type of effects reported and/or their distribution in the dose interval. The combination of the SciRAP and HAWC tools allowed for transparent evaluation and visualization of the studies investigating developmental effects of BPA on the mammary gland. The use of these tools showed that there were no apparent differences in the type of effects and their distribution in the dose interval between the five studies assessed as most reliable and the whole data set. Combining the SciRAP and HAWC tools was found to be a useful approach for evaluating in vivo toxicity studies and identifying reliable and sensitive information relevant to regulatory risk assessment of chemicals. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  9. [An instrument in Spanish to evaluate the performance of clinical teachers by students].

    PubMed

    Bitran, Marcela; Mena, Beltrán; Riquelme, Arnoldo; Padilla, Oslando; Sánchez, Ignacio; Moreno, Rodrigo

    2010-06-01

    The modernization of clinical teaching has called for the creation of faculty development programs, and the design of suitable instruments to evaluate clinical teachers' performance. To report the development and validation of an instrument in Spanish designed to measure the students' perceptions of their clinical teachers' performance and to provide them with feedback to improve their teaching practices. In a process that included the active participation of authorities, professors in charge of courses and internships, clinical teachers, students and medical education experts, we developed a 30-item questionnaire called MEDUC30 to evaluate the performance of clinical teachers by their students. The internal validity was assessed by factor analysis of 5214 evaluations of 265 teachers, gathered from 2004 to 2007. The reliability was measured with the Cronbach's alpha coefficient and the generalizability coefficient (g). MEDUC30 had good content and construct validity. Its internal structure was compatible with four factors: patient-centered teaching, teaching skills, assessment skills and learning climate, and it proved to be consistent with the structure anticipated by the theory. The scores were highly reliable (Cronbach's alpha: 0.97); five evaluations per teacher were sufficient to reach a reliability coefficient (g) of 0.8. MEDUC30 is a valid, reliable and useful instrument to evaluate the performance of clinical teachers. To our knowledge, this is the first instrument in Spanish for which solid validity and reliability evidences have been reported. We hope that MEDUC30 will be used to improve medical education in Spanish-speaking medical schools, providing teachers a specific feedback upon which to improve their pedagogical practice, and authorities with valuable information for the assessment of their faculty.

  10. Reliability and validity of Edinburgh visual gait score as an evaluation tool for children with cerebral palsy.

    PubMed

    Del Pilar Duque Orozco, Maria; Abousamra, Oussama; Church, Chris; Lennon, Nancy; Henley, John; Rogers, Kenneth J; Sees, Julieanne P; Connor, Justin; Miller, Freeman

    2016-09-01

    Assessment of gait abnormalities in cerebral palsy (CP) is challenging, and access to instrumented gait analysis is not always feasible. Therefore, many observational gait analysis scales have been devised. This study aimed to evaluate the interobserver reliability, intraobserver reliability, and validity of Edinburgh visual gait score (EVGS). Video of 30 children with spastic CP were reviewed by 7 raters (10 children each in GMFCS levels I, II, and III, age 6-12 years). Three observers had high level of experience in gait analysis (10+ years), two had medium level (2-5 years) and two had no previous experience (orthopedic fellows). Interobserver reliability was evaluated using percentage of complete agreement and kappa values. Criterion validity was evaluated by comparing EVGS scores with 3DGA data taken from the same video visit. Interobserver agreement was 60-90% and Kappa values were 0.18-0.85 for the 17 items in EVGS. Reliability was higher for distal segments (foot/ankle/knee 63-90%; trunk/pelvis/hip 60-76%), with greater experience (high 66-91%, medium 62-90%, no-experience 41-87%), with more EVGS practice (1st 10 videos 52-88%, last 10 videos 64-97%) and when used with higher functioning children (GMFCS I 65-96%, II 58-90%, III 35-65%). Intraobserver agreement was 64-92%. Agreement between EVGS and 3DGA was 52-73%. We believe that having EVGS as part of the standardized gait evaluation is helpful in optimizing the visual scoring. EVGS can be a supportive tool that adds quantitative data instead of only qualitative assessment to a video only gait evaluation. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. [Evaluation of Suicide Risk Levels in Hospitals: Validity and Reliability Tests].

    PubMed

    Macagnino, Sandro; Steinert, Tilman; Uhlmann, Carmen

    2018-05-01

    Examination of in-hospital suicide risk levels concerning their validity and their reliability. The internal suicide risk levels were evaluated in a cross sectional study of in 163 inpatients. A reliability check was performed via determining interrater-reliability of senior physician, therapist and the responsible nurse. Within the scope of the validity check, we conducted analyses of criterion validity and construct validity. For the total sample an "acceptable" to "good" interrater-reliability (Kendalls W = .77) of suicide risk levels were obtained. Schizophrenic disorders showed the lowest values, for personality disorders we found the highest level of interrater-reliability. When examining the criterion validity, Item-9 of the BDI-II is substantial correlated to our suicide risk levels (ρ m  = .54, p < .01). Within the scope of construct validity check, affective disorders showed the highest correlation (ρ = .77), compatible also with "convergent validity". They differed with schizophrenic disorders which showed the least concordance (ρ = .43). In-hospital suicide risk levels may represent an important contribution to the assessment of suicidal behavior of inpatients experiencing psychiatric treatment due to their overall good validity and reliability. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Developing Sustainable Life Support System Concepts

    NASA Technical Reports Server (NTRS)

    Thomas, Evan A.

    2010-01-01

    Sustainable spacecraft life support concepts may allow the development of more reliable technologies for long duration space missions. Currently, life support technologies at different levels of development are not well evaluated against each other, and evaluation methods do not account for long term reliability and sustainability of the hardware. This paper presents point-of-departure sustainability evaluation criteria for life support systems, that may allow more robust technology development, testing and comparison. An example sustainable water recovery system concept is presented.

  13. [Quality Assurance in Sociomedical Evaluation by Peer Review: A Pilot Project of the German Statutory Pension Insurance].

    PubMed

    Strahl, A; Gerlich, C; Wolf, H-D; Gehrke, J; Müller-Garnn, A; Vogel, H

    2016-03-01

    The sociomedical evaluation by the German Pension Insurance serves the purpose of determining entitlement to disability pensions. A quality assurance concept for the sociomedical evaluation was developed, which is based on a peer Review process. Peer review is an established process of external quality assurance in health care. The review is based on a hierarchically constructed manual that was evaluated in this pilot project. The database consists of 260 medical reports for disability pension of 12 pension insurance agencies. 771 reviews from 19 peers were included in the evaluation of the inter-rater reliability. Kendall's coefficient of concordance W for more than 2 raters is used as primary measure of inter-rater reliability. Reliability appeared to be heterogeneous. Kendalls W varies for the particular criteria from 0.09 to 0.88 and reached for primary criterion reproducibility a value of 0.37. The reliability of the manual seemed acceptable in the context of existing research data and is in line with existing peer review research outcomes. Nevertheless, the concordance is limited and requires optimisation. Starting points for improvement can be seen in a systematic training and regular user meetings of the peers involved. © Georg Thieme Verlag KG Stuttgart · New York.

  14. An evaluation of pediatric dental patient education materials using contemporary health literacy measures.

    PubMed

    Kang, Edith; Fields, Henry W; Cornett, Sandy; Beck, F Michael

    2005-01-01

    The purpose of this study was to determine the appropriateness of nationally available dental information materials according to the suitability assessment of materials (SAM) method. Clinically related, professionally produced patient dental health education materials (N=22) provided by the American Academy of Pediatric Dentistry (AAPD) were evaluated using the SAM method that had previously been judged valid and reliable. A rater was trained by an experienced health literacy evaluator to establish validity. The rater then rated all materials for 5 categories of assessment (content, literacy demand, graphics, layout and typography, and learning stimulation/motivation) and an overall assessment, and repeated 5 materials to establish intrarater reliability. When compared to the experienced rater, the validity was K=0.43. The reliability was established for all ratings as K=0.52. The consistently weakest categories were content, graphics, and learning stimulation, while reading level as part of literacy demand was often not suitable. The overall suitability of the AAPD materials was generally classified as superior. Reliable and valid evaluation of available dental patient information materials can be accomplished. The materials were largely superior. There is great variability within the categories of evaluation. The categories of content, graphics, and learning stimulation require attention and could raise the overall quality of the materials.

  15. The role of test-retest reliability in measuring individual and group differences in executive functioning.

    PubMed

    Paap, Kenneth R; Sawi, Oliver

    2016-12-01

    Studies testing for individual or group differences in executive functioning can be compromised by unknown test-retest reliability. Test-retest reliabilities across an interval of about one week were obtained from performance in the antisaccade, flanker, Simon, and color-shape switching tasks. There is a general trade-off between the greater reliability of single mean RT measures, and the greater process purity of measures based on contrasts between mean RTs in two conditions. The individual differences in RT model recently developed by Miller and Ulrich was used to evaluate the trade-off. Test-retest reliability was statistically significant for 11 of the 12 measures, but was of moderate size, at best, for the difference scores. The test-retest reliabilities for the Simon and flanker interference scores were lower than those for switching costs. Standard practice evaluates the reliability of executive-functioning measures using split-half methods based on data obtained in a single day. Our test-retest measures of reliability are lower, especially for difference scores. These reliability measures must also take into account possible day effects that classical test theory assumes do not occur. Measures based on single mean RTs tend to have acceptable levels of reliability and convergent validity, but are "impure" measures of specific executive functions. The individual differences in RT model shows that the impurity problem is worse than typically assumed. However, the "purer" measures based on difference scores have low convergent validity that is partly caused by deficiencies in test-retest reliability. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Reliability and Validity of the Italian Version of the Protocol of Orofacial Myofunctional Evaluation with Scores (I-OMES).

    PubMed

    Scarponi, Letizia; de Felicio, Claudia Maria; Sforza, Chiarella; Pimenta Ferreira, Claudia Lucia; Ginocchio, Daniela; Pizzorni, Nicole; Barozzi, Stefania; Mozzanica, Francesco; Schindler, Antonio

    2018-05-30

    To evaluate the reliability, validity, and responsiveness of the Italian OMES (I-OMES). The study consisted of 3 phases: (1) internal consistency and reliability, (2) validity, and (3) responsiveness analysis. The recruited population included 27 patients with orofacial myofunctional disorders (OMD) and 174 healthy volunteers. Forty-seven subjects, 18 healthy and all recruited patients with OMD were assessed for inter-rater and test-retest reliability analysis. I-OMES and Nordic Orofacial Test - Screening (NOT-S) scores of the patients were correlated for concurrent validity analysis. I-OMES scores from 27 patients with OMD and 27 age- and gender-matched healthy subjects were compared to investigate construct validity. I-OMES scores before and after successful swallowing rehabilitation in patients were compared for responsiveness analysis. Adequate internal consistency (Cronbach α = 0.71) and strong inter-rater and test-retest reliability (intraclass coefficient correlation = 0.97 and 0.98, respectively) were found. I-OMES and NOT-S scores significantly and inversely correlated (r = -0.38). A statistical significance (p < 0.001) was found between the pathological group and the control group for the total I-OMES score. The mean I-OMES score improved from 90 (78-102) to 99 (89-103) after myofunctional rehabilitation (p < 0.001). The I-OMES is a reliable and valid tool to evaluate OMD. © 2018 S. Karger AG, Basel.

  17. Reducing random measurement error in assessing postural load on the back in epidemiologic surveys.

    PubMed

    Burdorf, A

    1995-02-01

    The goal of this study was to design strategies to assess postural load on the back in occupational epidemiology by taking into account the reliability of measurement methods and the variability of exposure among the workers under study. Intermethod reliability studies were evaluated to estimate the systematic bias (accuracy) and random measurement error (precision) of various methods to assess postural load on the back. Intramethod reliability studies were reviewed to estimate random variability of back load over time. Intermethod surveys have shown that questionnaires have a moderate reliability for gross activities such as sitting, whereas duration of trunk flexion and rotation should be assessed by observation methods or inclinometers. Intramethod surveys indicate that exposure variability can markedly affect the reliability of estimates of back load if the estimates are based upon a single measurement over a certain time period. Equations have been presented to evaluate various study designs according to the reliability of the measurement method, the optimum allocation of the number of repeated measurements per subject, and the number of subjects in the study. Prior to a large epidemiologic study, an exposure-oriented survey should be conducted to evaluate the performance of measurement instruments and to estimate sources of variability for back load. The strategy for assessing back load can be optimized by balancing the number of workers under study and the number of repeated measurements per worker.

  18. An In vitro evaluation of the reliability of QR code denture labeling technique.

    PubMed

    Poovannan, Sindhu; Jain, Ashish R; Krishnan, Cakku Jalliah Venkata; Chandran, Chitraa R

    2016-01-01

    Positive identification of the dead after accidents and disasters through labeled dentures plays a key role in forensic scenario. A number of denture labeling methods are available, and studies evaluating their reliability under drastic conditions are vital. This study was conducted to evaluate the reliability of QR (Quick Response) Code labeled at various depths in heat-cured acrylic blocks after acid treatment, heat treatment (burns), and fracture in forensics. It was an in vitro study. This study included 160 specimens of heat-cured acrylic blocks (1.8 cm × 1.8 cm) and these were divided into 4 groups (40 samples per group). QR Codes were incorporated in the samples using clear acrylic sheet and they were assessed for reliability under various depths, acid, heat, and fracture. Data were analyzed using Chi-square test, test of proportion. The QR Code inclusion technique was reliable under various depths of acrylic sheet, acid (sulfuric acid 99%, hydrochloric acid 40%) and heat (up to 370°C). Results were variable with fracture of QR Code labeled acrylic blocks. Within the limitations of the study, by analyzing the results, it was clearly indicated that the QR Code technique was reliable under various depths of acrylic sheet, acid, and heat (370°C). Effectiveness varied in fracture and depended on the level of distortion. This study thus suggests that QR Code is an effective and simpler denture labeling method.

  19. Relevance and reliability of experimental data in human health risk assessment of pesticides.

    PubMed

    Kaltenhäuser, Johanna; Kneuer, Carsten; Marx-Stoelting, Philip; Niemann, Lars; Schubert, Jens; Stein, Bernd; Solecki, Roland

    2017-08-01

    Evaluation of data relevance, reliability and contribution to uncertainty is crucial in regulatory health risk assessment if robust conclusions are to be drawn. Whether a specific study is used as key study, as additional information or not accepted depends in part on the criteria according to which its relevance and reliability are judged. In addition to GLP-compliant regulatory studies following OECD Test Guidelines, data from peer-reviewed scientific literature have to be evaluated in regulatory risk assessment of pesticide active substances. Publications should be taken into account if they are of acceptable relevance and reliability. Their contribution to the overall weight of evidence is influenced by factors including test organism, study design and statistical methods, as well as test item identification, documentation and reporting of results. Various reports make recommendations for improving the quality of risk assessments and different criteria catalogues have been published to support evaluation of data relevance and reliability. Their intention was to guide transparent decision making on the integration of the respective information into the regulatory process. This article describes an approach to assess the relevance and reliability of experimental data from guideline-compliant studies as well as from non-guideline studies published in the scientific literature in the specific context of uncertainty and risk assessment of pesticides. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  20. Reliability of specific physical examination tests for the diagnosis of shoulder pathologies: a systematic review and meta-analysis.

    PubMed

    Lange, Toni; Matthijs, Omer; Jain, Nitin B; Schmitt, Jochen; Lützner, Jörg; Kopkow, Christian

    2017-03-01

    Shoulder pain in the general population is common and to identify the aetiology of shoulder pain, history, motion and muscle testing, and physical examination tests are usually performed. The aim of this systematic review was to summarise and evaluate intrarater and inter-rater reliability of physical examination tests in the diagnosis of shoulder pathologies. A comprehensive systematic literature search was conducted using MEDLINE, EMBASE, Allied and Complementary Medicine Database (AMED) and Physiotherapy Evidence Database (PEDro) through 20 March 2015. Methodological quality was assessed using the Quality Appraisal of Reliability Studies (QAREL) tool by 2 independent reviewers. The search strategy revealed 3259 articles, of which 18 finally met the inclusion criteria. These studies evaluated the reliability of 62 test and test variations used for the specific physical examination tests for the diagnosis of shoulder pathologies. Methodological quality ranged from 2 to 7 positive criteria of the 11 items of the QAREL tool. This review identified a lack of high-quality studies evaluating inter-rater as well as intrarater reliability of specific physical examination tests for the diagnosis of shoulder pathologies. In addition, reliability measures differed between included studies hindering proper cross-study comparisons. PROSPERO CRD42014009018. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  1. The precision and reliability evaluation of 3-dimensional printed damaged bone and prosthesis models by stereo lithography appearance

    PubMed Central

    Zou, Yun; Han, Qing; Weng, Xisheng; Zou, Yongwei; Yang, Yingying; Zhang, Kesong; Yang, Kerong; Xu, Xiaolin; Wang, Chenyu; Qin, Yanguo; Wang, Jincheng

    2018-01-01

    Abstract Recently, clinical application of 3D printed model was increasing. However, there was no systemic study for confirming the precision and reliability of 3D printed model. Some senior clinical doctors mistrusted its reliability in clinical application. The purpose of this study was to evaluate the precision and reliability of stereolithography appearance (SLA) 3D printed model. Some related parameters were selected to research the reliability of SLA 3D printed model. The computed tomography (CT) data of bone/prosthesis and model were collected and 3D reconstructed. Some anatomical parameters were measured and statistical analysis was performed; the intraclass correlation coefficient (ICC) was used to was used to evaluate the similarity between the model and real bone/prosthesis. the absolute difference (mm) and relative difference (%) were conducted. For prosthesis model, the 3-dimensional error was measured. There was no significant difference in the anatomical parameters except max height (MH) of long bone. All the ICCs were greater than 0.990. The maximum absolute and relative difference were 0.45 mm and 1.10%; The 3-dimensional error analysis showed that positive/minus distance were 0.273 mm/0.237 mm. The application of SLA 3D printed model in diagnosis and treatment process of complex orthopedic disease was reliable and precise. PMID:29419675

  2. The precision and reliability evaluation of 3-dimensional printed damaged bone and prosthesis models by stereo lithography appearance.

    PubMed

    Zou, Yun; Han, Qing; Weng, Xisheng; Zou, Yongwei; Yang, Yingying; Zhang, Kesong; Yang, Kerong; Xu, Xiaolin; Wang, Chenyu; Qin, Yanguo; Wang, Jincheng

    2018-02-01

    Recently, clinical application of 3D printed model was increasing. However, there was no systemic study for confirming the precision and reliability of 3D printed model. Some senior clinical doctors mistrusted its reliability in clinical application. The purpose of this study was to evaluate the precision and reliability of stereolithography appearance (SLA) 3D printed model.Some related parameters were selected to research the reliability of SLA 3D printed model. The computed tomography (CT) data of bone/prosthesis and model were collected and 3D reconstructed. Some anatomical parameters were measured and statistical analysis was performed; the intraclass correlation coefficient (ICC) was used to was used to evaluate the similarity between the model and real bone/prosthesis. the absolute difference (mm) and relative difference (%) were conducted. For prosthesis model, the 3-dimensional error was measured.There was no significant difference in the anatomical parameters except max height (MH) of long bone. All the ICCs were greater than 0.990. The maximum absolute and relative difference were 0.45 mm and 1.10%; The 3-dimensional error analysis showed that positive/minus distance were 0.273 mm/0.237 mm.The application of SLA 3D printed model in diagnosis and treatment process of complex orthopedic disease was reliable and precise.

  3. Reliability and validity of a talent identification test battery for seated and standing Paralympic throws.

    PubMed

    Spathis, Jemima Grace; Connick, Mark James; Beckman, Emma Maree; Newcombe, Peter Anthony; Tweedy, Sean Michael

    2015-01-01

    Paralympic throwing events for athletes with physical impairments comprise seated and standing javelin, shot put, discus and seated club throwing. Identification of talented throwers would enable prediction of future success and promote participation; however, a valid and reliable talent identification battery for Paralympic throwing has not been reported. This study evaluates the reliability and validity of a talent identification battery for Paralympic throws. Participants were non-disabled so that impairment would not confound analyses, and results would provide an indication of normative performance. Twenty-eight non-disabled participants (13 M; 15 F) aged 23.6 years (±5.44) performed five kinematically distinct criterion throws (three seated, two standing) and nine talent identification tests (three anthropometric, six motor); 23 were tested a second time to evaluate test-retest reliability. Talent identification test-retest reliability was evaluated using Intra-class Correlation Coefficient (ICC) and Bland-Altman plots (Limits of Agreement). Spearman's correlation assessed strength of association between criterion throws and talent identification tests. Reliability was generally acceptable (mean ICC = 0.89), but two seated talent identification tests require more extensive familiarisation. Correlation strength (mean rs = 0.76) indicated that the talent identification tests can be used to validly identify individuals with competitively advantageous attributes for each of the five kinematically distinct throwing activities. Results facilitate further research in this understudied area.

  4. [Reliability of a positron emission tomography system (CTI:PT931/04-12)].

    PubMed

    Watanuki, Shoichi; Ishii, Keizo; Itoh, Masatoshi; Orihara, Hikonojyo

    2002-05-01

    The maintenance data of a PET system (PT931/04-12 CTI Inc.) was analyzed to evaluate its reliability. We examined whether the initial performance for the system resolution and efficiency is kept. The reliability of the PET system was evaluated from the value of MTTF (mean time to failure) and MTBF (mean time between failures) for each part of the system obtained from the maintenance data for 13 years. The initial performance was kept for the resolution, but the efficiency decreased to 72% of the initial value. The 83% of the troubles of the system was for detector block (DB) and DB control module (BC). The MTTF of DB and BC were 2,733 and 3,314 days, and the MTBF of DB and BC per detector ring were 38 and 114 days. The MTBF of the system was 23 days. We found seasonal dependence for the number of troubles of DB and BC. This means that the trouble may be related the humidity. The reliability of the PET system strongly depends on the MTBF of DB and BC. The improvement in quality of these parts and optimization of the environment in operation may increase the reliability of the PET system. For the popularization of PET, it is effective to evaluate the reliability of the system and to show it to the users.

  5. Validation of the Spanish adaptation of the Consensus Auditory-Perceptual Evaluation of Voice (CAPE-V).

    PubMed

    Núñez-Batalla, Faustino; Morato-Galán, Marta; García-López, Isabel; Ávila-Menéndez, Arántzazu

    2015-01-01

    The Consensus Auditory-Perceptual Evaluation of Voice (CAPE-V) was developed.to promote a standardised approach to evaluating and documenting auditory perceptual judgments of vocal quality. This tool was originally developed in English language and its Spanish version is still inexistent. The aim of this study was to develop a Spanish adaptation of CAPE-V and to examine the reliability and empirical validity of this Spanish version. To adapt the CAPE-V protocol to the Spanish language, we proposed 6 phrases phonetically designed according to the CAPE-V requirements. Prospective instrument validation was performed. The validity of the Spanish version of the CAPE-V was examined in 4 ways: intra-rater reliability, inter-rater reliability and CAPE-V versus GRABS judgments. Inter-rater reliability coefficients for the CAPE-V ranged from 0.93 for overall severity to 0.54 for intensity; intra-rater reliability ranged from 0.98 for overall severity to 0.85 for intensity. The comparison of judgments between GRABS and CAPE-V ranged from 0.86 for overall severity to 0.61 for breathiness. The present study supports the use of the Spanish version of CAPE-V because of its validity and reliability. Copyright © 2014 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Patología Cérvico-Facial. All rights reserved.

  6. Standards and reliability in evaluation: when rules of thumb don't apply.

    PubMed

    Norcini, J J

    1999-10-01

    The purpose of this paper is to identify situations in which two rules of thumb in evaluation do not apply. The first rule is that all standards should be absolute. When selection decisions are being made or when classroom tests are given, however, relative standards may be better. The second rule of thumb is that every test should have a reliability of .80 or better. Depending on the circumstances, though, the standard error of measurement, the consistency of pass/fail classifications, and the domain-referenced reliability coefficients may be better indicators of reproducibility.

  7. Beyond the buildingcentric approach: A vision for an integrated evaluation of sustainable buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Conte, Emilia, E-mail: conte@poliba.it; Monno, Valeria, E-mail: vmonno@poliba.it

    2012-04-15

    The available sustainable building evaluation systems have produced a new environmental design paradigm. However, there is an increasing need to overcome the buildingcentric approach of these systems, in order to further exploit their innovate potential for sustainable building practices. The paper takes this challenge by developing a cross-scale evaluation approach focusing on the reliability of sustainable building design solutions for the context in which the building is situated. An integrated building-urban evaluation model is proposed based on the urban matrix, which is a conceptualisation of the built environment as a social-ecological system. The model aims at evaluating the sustainability ofmore » a building considering it as an active entity contributing to the resilience of the urban matrix. Few holistic performance indicators are used for evaluating such contribution, so expressing the building reliability. The discussion on the efficacy of the model shows that it works as a heuristic tool, supporting the acquisition of a better insight into the complexity which characterises the relationships between the building and the built environment sustainability. Shading new lights on the meaning of sustainable buildings, the model can play a positive role in innovating sustainable building design practices, thus complementing current evaluation systems. - Highlights: Black-Right-Pointing-Pointer We model an integrated building-urban evaluation approach. Black-Right-Pointing-Pointer The urban matrix represents the social-ecological functioning of the urban context. Black-Right-Pointing-Pointer We introduce the concept of reliability to evaluate sustainable buildings. Black-Right-Pointing-Pointer Holistic indicators express the building reliability. Black-Right-Pointing-Pointer The evaluation model works as heuristic tool and complements other tools.« less

  8. Is School-Based Height and Weight Screening of Elementary Students Private and Reliable?

    ERIC Educational Resources Information Center

    Stoddard, Sarah A.; Kubik, Martha Y.; Skay, Carol

    2008-01-01

    The Institute of Medicine recommends school-based body mass index (BMI) screening as an obesity prevention strategy. While school nurses have provided height/weight screening for years, little has been published describing measurement reliability or process. This study evaluated the reliability of height/weight measures collected by school nurses…

  9. Reliability and Validity of Information about Student Achievement: Comparing Large-Scale and Classroom Testing Contexts

    ERIC Educational Resources Information Center

    Cizek, Gregory J.

    2009-01-01

    Reliability and validity are two characteristics that must be considered whenever information about student achievement is collected. However, those characteristics--and the methods for evaluating them--differ in large-scale testing and classroom testing contexts. This article presents the distinctions between reliability and validity in the two…

  10. The Reliability, Impact, and Cost-Effectiveness of Value-Added Teacher Assessment Methods

    ERIC Educational Resources Information Center

    Yeh, Stuart S.

    2012-01-01

    This article reviews evidence regarding the intertemporal reliability of teacher rankings based on value-added methods. Value-added methods exhibit low reliability, yet are broadly supported by prominent educational researchers and are increasingly being used to evaluate and fire teachers. The article then presents a cost-effectiveness analysis…

  11. Reliability and precision of pellet-group counts for estimating landscape-level deer density

    Treesearch

    David S. deCalesta

    2013-01-01

    This study provides hitherto unavailable methodology for reliably and precisely estimating deer density within forested landscapes, enabling quantitative rather than qualitative deer management. Reliability and precision of the deer pellet-group technique were evaluated in 1 small and 2 large forested landscapes. Density estimates, adjusted to reflect deer harvest and...

  12. Reliability and Validity of Finger Strength and Endurance Measurements in Rock Climbing

    ERIC Educational Resources Information Center

    Michailov, Michail Lubomirov; Baláš, Jirí; Tanev, Stoyan Kolev; Andonov, Hristo Stoyanov; Kodejška, Jan; Brown, Lee

    2018-01-01

    Purpose: An advanced system for the assessment of climbing-specific performance was developed and used to: (a) investigate the effect of arm fixation (AF) on construct validity evidence and reliability of climbing-specific finger-strength measurement; (b) assess reliability of finger-strength and endurance measurements; and (c) evaluate the…

  13. A Validity and Reliability Update on the Informal Reading Inventory with Suggestions for Improvement.

    ERIC Educational Resources Information Center

    Klesius, Janell P.; Homan, Susan P.

    1985-01-01

    The article reviews validity and reliability studies on the informal reading inventory, a diagnostic instrument to identify reading grade-level placement and strengths and weaknesses in work recognition and comprehension. Gives suggestions to improve the validity and reliability of existing inventories and to evaluate them in newly published…

  14. Impact of Device Scaling on Deep Sub-micron Transistor Reliability: A Study of Reliability Trends using SRAM

    NASA Technical Reports Server (NTRS)

    White, Mark; Huang, Bing; Qin, Jin; Gur, Zvi; Talmor, Michael; Chen, Yuan; Heidecker, Jason; Nguyen, Duc; Bernstein, Joseph

    2005-01-01

    As microelectronics are scaled in to the deep sub-micron regime, users of advanced technology CMOS, particularly in high-reliability applications, should reassess how scaling effects impact long-term reliability. An experimental based reliability study of industrial grade SRAMs, consisting of three different technology nodes, is proposed to substantiate current acceleration models for temperature and voltage life-stress relationships. This reliability study utilizes step-stress techniques to evaluate memory technologies (0.25mum, 0.15mum, and 0.13mum) embedded in many of today's high-reliability space/aerospace applications. Two acceleration modeling approaches are presented to relate experimental FIT calculations to Mfr's qualification data.

  15. Bayesian Inference for NASA Probabilistic Risk and Reliability Analysis

    NASA Technical Reports Server (NTRS)

    Dezfuli, Homayoon; Kelly, Dana; Smith, Curtis; Vedros, Kurt; Galyean, William

    2009-01-01

    This document, Bayesian Inference for NASA Probabilistic Risk and Reliability Analysis, is intended to provide guidelines for the collection and evaluation of risk and reliability-related data. It is aimed at scientists and engineers familiar with risk and reliability methods and provides a hands-on approach to the investigation and application of a variety of risk and reliability data assessment methods, tools, and techniques. This document provides both: A broad perspective on data analysis collection and evaluation issues. A narrow focus on the methods to implement a comprehensive information repository. The topics addressed herein cover the fundamentals of how data and information are to be used in risk and reliability analysis models and their potential role in decision making. Understanding these topics is essential to attaining a risk informed decision making environment that is being sought by NASA requirements and procedures such as 8000.4 (Agency Risk Management Procedural Requirements), NPR 8705.05 (Probabilistic Risk Assessment Procedures for NASA Programs and Projects), and the System Safety requirements of NPR 8715.3 (NASA General Safety Program Requirements).

  16. Reliability of Radioisotope Stirling Convertor Linear Alternator

    NASA Technical Reports Server (NTRS)

    Shah, Ashwin; Korovaichuk, Igor; Geng, Steven M.; Schreiber, Jeffrey G.

    2006-01-01

    Onboard radioisotope power systems being developed and planned for NASA s deep-space missions would require reliable design lifetimes of up to 14 years. Critical components and materials of Stirling convertors have been undergoing extensive testing and evaluation in support of a reliable performance for the specified life span. Of significant importance to the successful development of the Stirling convertor is the design of a lightweight and highly efficient linear alternator. Alternator performance could vary due to small deviations in the permanent magnet properties, operating temperature, and component geometries. Durability prediction and reliability of the alternator may be affected by these deviations from nominal design conditions. Therefore, it is important to evaluate the effect of these uncertainties in predicting the reliability of the linear alternator performance. This paper presents a study in which a reliability-based methodology is used to assess alternator performance. The response surface characterizing the induced open-circuit voltage performance is constructed using 3-D finite element magnetic analysis. Fast probability integration method is used to determine the probability of the desired performance and its sensitivity to the alternator design parameters.

  17. Validation of the INCEPT: A Multisource Feedback Tool for Capturing Different Perspectives on Physicians' Professional Performance.

    PubMed

    van der Meulen, Mirja W; Boerebach, Benjamin C M; Smirnova, Alina; Heeneman, Sylvia; Oude Egbrink, Mirjam G A; van der Vleuten, Cees P M; Arah, Onyebuchi A; Lombarts, Kiki M J M H

    2017-01-01

    Multisource feedback (MSF) instruments are used to and must feasibly provide reliable and valid data on physicians' performance from multiple perspectives. The "INviting Co-workers to Evaluate Physicians Tool" (INCEPT) is a multisource feedback instrument used to evaluate physicians' professional performance as perceived by peers, residents, and coworkers. In this study, we report on the validity, reliability, and feasibility of the INCEPT. The performance of 218 physicians was assessed by 597 peers, 344 residents, and 822 coworkers. Using explorative and confirmatory factor analyses, multilevel regression analyses between narrative and numerical feedback, item-total correlations, interscale correlations, Cronbach's α and generalizability analyses, the psychometric qualities, and feasibility of the INCEPT were investigated. For all respondent groups, three factors were identified, although constructed slightly different: "professional attitude," "patient-centeredness," and "organization and (self)-management." Internal consistency was high for all constructs (Cronbach's α ≥ 0.84 and item-total correlations ≥ 0.52). Confirmatory factor analyses indicated acceptable to good fit. Further validity evidence was given by the associations between narrative and numerical feedback. For reliable total INCEPT scores, three peer, two resident and three coworker evaluations were needed; for subscale scores, evaluations of three peers, three residents and three to four coworkers were sufficient. The INCEPT instrument provides physicians performance feedback in a valid and reliable way. The number of evaluations to establish reliable scores is achievable in a regular clinical department. When interpreting feedback, physicians should consider that respondent groups' perceptions differ as indicated by the different item clustering per performance factor.

  18. Reliability analysis of composite structures

    NASA Technical Reports Server (NTRS)

    Kan, Han-Pin

    1992-01-01

    A probabilistic static stress analysis methodology has been developed to estimate the reliability of a composite structure. Closed form stress analysis methods are the primary analytical tools used in this methodology. These structural mechanics methods are used to identify independent variables whose variations significantly affect the performance of the structure. Once these variables are identified, scatter in their values is evaluated and statistically characterized. The scatter in applied loads and the structural parameters are then fitted to appropriate probabilistic distribution functions. Numerical integration techniques are applied to compute the structural reliability. The predicted reliability accounts for scatter due to variability in material strength, applied load, fabrication and assembly processes. The influence of structural geometry and mode of failure are also considerations in the evaluation. Example problems are given to illustrate various levels of analytical complexity.

  19. Development and psychometric evaluation of supportive leadership scales.

    PubMed

    McGilton, Katherine S

    2003-12-01

    The purpose of this study was to develop and evaluate the psychometric properties of 2 supportive leadership scales, the Charge Nurse Support Scale and the Unit Manager Support Scale, designed for long-term-care environments. These 6-item self-report scales were administered to 70 nursing staff and their internal consistency reliability, test-retest reliability, content validity, factor structure, and construct validity investigated. Content validity was established with the assistance of experts. Both scales were deemed reliable. As hypothesized, a significant relationship was found between the measure of how nursing staff related to residents and measures of charge nurses' supportive behaviours (r = .42, p = .05). Reliable and valid measures of supportive leadership could be developed for use in identifying the quality of support provided to staff in long-term-care environments.

  20. Psychometric Evaluation of the D-Catch, an Instrument to Measure the Accuracy of Nursing Documentation.

    PubMed

    D'Agostino, Fabio; Barbaranelli, Claudio; Paans, Wolter; Belsito, Romina; Juarez Vela, Raul; Alvaro, Rosaria; Vellone, Ercole

    2017-07-01

    To evaluate the psychometric properties of the D-Catch instrument. A cross-sectional methodological study. Validity and reliability were estimated with confirmatory factor analysis (CFA) and internal consistency and inter-rater reliability, respectively. A sample of 250 nursing documentations was selected. CFA showed the adequacy of a 1-factor model (chronologically descriptive accuracy) with an outlier item (nursing diagnosis accuracy). Internal consistency and inter-rater reliability were adequate. The D-Catch is a valid and reliable instrument for measuring the accuracy of nursing documentation. Caution is needed when measuring diagnostic accuracy since only one item measures this dimension. The D-Catch can be used as an indicator of the accuracy of nursing documentation and the quality of nursing care. © 2015 NANDA International, Inc.

Top