Sample records for mppt efficiency evaluation

  1. Dynamic Performance of Maximum Power Point Trackers in TEG Systems Under Rapidly Changing Temperature Conditions

    NASA Astrophysics Data System (ADS)

    Man, E. A.; Sera, D.; Mathe, L.; Schaltz, E.; Rosendahl, L.

    2016-03-01

    Characterization of thermoelectric generators (TEG) is widely discussed and equipment has been built that can perform such analysis. One method is often used to perform such characterization: constant temperature with variable thermal power input. Maximum power point tracking (MPPT) methods for TEG systems are mostly tested under steady-state conditions for different constant input temperatures. However, for most TEG applications, the input temperature gradient changes, exposing the MPPT to variable tracking conditions. An example is the exhaust pipe on hybrid vehicles, for which, because of the intermittent operation of the internal combustion engine, the TEG and its MPPT controller are exposed to a cyclic temperature profile. Furthermore, there are no guidelines on how fast the MPPT must be under such dynamic conditions. In the work discussed in this paper, temperature gradients for TEG integrated in several applications were evaluated; the results showed temperature variation up to 5°C/s for TEG systems. Electrical characterization of a calcium-manganese oxide TEG was performed at steady-state for different input temperatures and a maximum temperature of 401°C. By using electrical data from characterization of the oxide module, a solar array simulator was emulated to perform as a TEG. A trapezoidal temperature profile with different gradients was used on the TEG simulator to evaluate the dynamic MPPT efficiency. It is known that the perturb and observe (P&O) algorithm may have difficulty accurately tracking under rapidly changing conditions. To solve this problem, a compromise must be found between the magnitude of the increment and the sampling frequency of the control algorithm. The standard P&O performance was evaluated experimentally by using different temperature gradients for different MPPT sampling frequencies, and efficiency values are provided for all cases. The results showed that a tracking speed of 2.5 Hz can be successfully implemented on a TEG system to provide ˜95% MPPT efficiency when the input temperature is changing at 5°C/s.

  2. Performance analysis of ‘Perturb and Observe’ and ‘Incremental Conductance’ MPPT algorithms for PV system

    NASA Astrophysics Data System (ADS)

    Lodhi, Ehtisham; Lodhi, Zeeshan; Noman Shafqat, Rana; Chen, Fieda

    2017-07-01

    Photovoltaic (PV) system usually employed The Maximum power point tracking (MPPT) techniques for increasing its efficiency. The performance of the PV system perhaps boosts by controlling at its apex point of power, in this way maximal power can be given to load. The proficiency of a PV system usually depends upon irradiance, temperature and array architecture. PV array shows a non-linear style for V-I curve and maximal power point on V-P curve also varies with changing environmental conditions. MPPT methods grantees that a PV module is regulated at reference voltage and to produce entire usage of the maximal output power. This paper gives analysis between two widely employed Perturb and Observe (P&O) and Incremental Conductance (INC) MPPT techniques. Their performance is evaluated and compared through theoretical analysis and digital simulation on the basis of response time and efficiency under varying irradiance and temperature condition using Matlab/Simulink.

  3. Highly efficient maximum power point tracking using DC-DC coupled inductor single-ended primary inductance converter for photovoltaic power systems

    NASA Astrophysics Data System (ADS)

    Quamruzzaman, M.; Mohammad, Nur; Matin, M. A.; Alam, M. R.

    2016-10-01

    Solar photovoltaics (PVs) have nonlinear voltage-current characteristics, with a distinct maximum power point (MPP) depending on factors such as solar irradiance and operating temperature. To extract maximum power from the PV array at any environmental condition, DC-DC converters are usually used as MPP trackers. This paper presents the performance analysis of a coupled inductor single-ended primary inductance converter for maximum power point tracking (MPPT) in a PV system. A detailed model of the system has been designed and developed in MATLAB/Simulink. The performance evaluation has been conducted on the basis of stability, current ripple reduction and efficiency at different operating conditions. Simulation results show considerable ripple reduction in the input and output currents of the converter. Both the MPPT and converter efficiencies are significantly improved. The obtained simulation results validate the effectiveness and suitability of the converter model in MPPT and show reasonable agreement with the theoretical analysis.

  4. Dynamic Performance Comparison for MPPT-PV Systems using Hybrid Pspice/Matlab Simulation

    NASA Astrophysics Data System (ADS)

    Aouchiche, N.; Becherif, M.; HadjArab, A.; Aitcheikh, M. S.; Ramadan, H. S.; Cheknane, A.

    2016-10-01

    The power generated by solar photovoltaic (PV) module depends on the surrounding irradiance and temperature. This paper presents a hybrid Matlab™/Pspice™ simulation model of PV system, combined with Cadence software SLPS. The hybridization is performed in order to gain the advantages of both simulation tools such as accuracy and efficiency in both Pspice electronic circuit and Matlab™ mathematical modelling respectively. For this purpose, the PV panel and the boost converter are developed using Pspice™ and hybridized with the mathematical Matlab™ model of maximum power point method controller (MPPT) through SLPS. The main objective is verify the significance of using the proposed hybrid simulation techniques in comparing the different MPPT algorithms such as the perturbation and observation (P&O), incremental of conductance (Inc-Cond) and counter reaction voltage using pilot cell (Pilot-Cell). Various simulations are performed under different atmospheric conditions in order to evaluate the dynamic behaviour for the system under study in terms of stability, efficiency and rapidity.

  5. Simulation and experimental design of a new advanced variable step size Incremental Conductance MPPT algorithm for PV systems.

    PubMed

    Loukriz, Abdelhamid; Haddadi, Mourad; Messalti, Sabir

    2016-05-01

    Improvement of the efficiency of photovoltaic system based on new maximum power point tracking (MPPT) algorithms is the most promising solution due to its low cost and its easy implementation without equipment updating. Many MPPT methods with fixed step size have been developed. However, when atmospheric conditions change rapidly , the performance of conventional algorithms is reduced. In this paper, a new variable step size Incremental Conductance IC MPPT algorithm has been proposed. Modeling and simulation of different operational conditions of conventional Incremental Conductance IC and proposed methods are presented. The proposed method was developed and tested successfully on a photovoltaic system based on Flyback converter and control circuit using dsPIC30F4011. Both, simulation and experimental design are provided in several aspects. A comparative study between the proposed variable step size and fixed step size IC MPPT method under similar operating conditions is presented. The obtained results demonstrate the efficiency of the proposed MPPT algorithm in terms of speed in MPP tracking and accuracy. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.

  6. High Step-Up DC—DC Converter for AC Photovoltaic Module with MPPT Control

    NASA Astrophysics Data System (ADS)

    Sundar, Govindasamy; Karthick, Narashiman; Rama Reddy, Sasi

    2014-08-01

    This paper presents the high gain step-up BOOST converter which is essential to step up the low output voltage from PV panel to the high voltage according to the requirement of the application. In this paper a high gain BOOST converter with coupled inductor technique is proposed with the MPPT control. Without extreme duty ratios and the numerous turns-ratios of a coupled inductor this converter achieves a high step-up voltage-conversion ratio and the leakage energy of the coupled inductor is efficiently recycled to the load. MPPT control used to extract the maximum power from PV panel by controlling the Duty ratio of the converter. The PV panel, BOOST converter and the MPPT are modeled using Sim Power System blocks in MATLAB/SIMULINK environment. The prototype model of the proposed converter has been implemented with the maximum measured efficiency is up to 95.4% and full-load efficiency is 93.1%.

  7. Comparison of P&O and INC Methods in Maximum Power Point Tracker for PV Systems

    NASA Astrophysics Data System (ADS)

    Chen, Hesheng; Cui, Yuanhui; Zhao, Yue; Wang, Zhisen

    2018-03-01

    In the context of renewable energy, the maximum power point tracker (MPPT) is often used to increase the solar power efficiency, taking into account the randomness and volatility of solar energy due to changes in temperature and photovoltaic. In all MPPT techniques, perturb & observe and incremental conductance are widely used in MPPT controllers, because of their simplicity and ease of operation. According to the internal structure of the photovoltaic cell and the output volt-ampere characteristic, this paper established the circuit model and establishes the dynamic simulation model in Matlab/Simulink with the preparation of the s function. The perturb & observe MPPT method and the incremental conductance MPPT method were analyzed and compared by the theoretical analysis and digital simulation. The simulation results have shown that the system with INC MPPT method has better dynamic performance and improves the output power of photovoltaic power generation.

  8. Realworld maximum power point tracking simulation of PV system based on Fuzzy Logic control

    NASA Astrophysics Data System (ADS)

    Othman, Ahmed M.; El-arini, Mahdi M. M.; Ghitas, Ahmed; Fathy, Ahmed

    2012-12-01

    In the recent years, the solar energy becomes one of the most important alternative sources of electric energy, so it is important to improve the efficiency and reliability of the photovoltaic (PV) systems. Maximum power point tracking (MPPT) plays an important role in photovoltaic power systems because it maximize the power output from a PV system for a given set of conditions, and therefore maximize their array efficiency. This paper presents a maximum power point tracker (MPPT) using Fuzzy Logic theory for a PV system. The work is focused on the well known Perturb and Observe (P&O) algorithm and is compared to a designed fuzzy logic controller (FLC). The simulation work dealing with MPPT controller; a DC/DC Ćuk converter feeding a load is achieved. The results showed that the proposed Fuzzy Logic MPPT in the PV system is valid.

  9. Microprocessor-controlled step-down maximum-power-point tracker for photovoltaic systems

    NASA Astrophysics Data System (ADS)

    Mazmuder, R. K.; Haidar, S.

    1992-12-01

    An efficient maximum power point tracker (MPPT) has been developed and can be used with a photovoltaic (PV) array and a load which requires lower voltage than the PV array voltage to be operated. The MPPT makes the PV array to operate at maximum power point (MPP) under all insolation and temperature, which ensures the maximum amount of available PV power to be delivered to the load. The performance of the MPPT has been studied under different insolation levels.

  10. Solar Panel System for Street Light Using Maximum Power Point Tracking (MPPT) Technique

    NASA Astrophysics Data System (ADS)

    Wiedjaja, A.; Harta, S.; Josses, L.; Winardi; Rinda, H.

    2014-03-01

    Solar energy is one form of the renewable energy which is very abundant in regions close to the equator. One application of solar energy is for street light. This research focuses on using the maximum power point tracking technique (MPPT), particularly the perturb and observe (P&O) algorithm, to charge battery for street light system. The proposed charger circuit can achieve 20.73% higher power efficiency compared to that of non-MPPT charger. We also develop the LED driver circuit for the system which can achieve power efficiency up to 91.9% at a current of 1.06 A. The proposed street lightning system can be implemented with a relatively low cost for public areas.

  11. The use of a micropore particle technology in the treatment of acute wounds.

    PubMed

    Ryan, E

    2017-07-02

    A clinical audit was performed to evaluate whether Acapsil micropore particle technology (MPPT) powder could improve the management of acute wounds to heal by secondary intention. Wounds, which could be characterised as sloughy, wet and probably infected, normally managed by debridement followed by negative pressure wound therapy (NPWT), were included in the evaluation. The MPPT powder was applied topically to the wound surface either once daily or on alternate days, with each wound receiving a total of two to five applications. Most patients had NPWT after the MPPT powder treatment had finished to assist healing. The study included nine patients with dehisced surgical wounds and one with a category IV pressure ulcer (PU). The wounds were generally covered in slough, exudate and showing signs of local infection. The topical MPPT powder rapidly desloughed the wounds, controlled exudate levels, promoted granulation and was well tolerated. All wounds proceeded towards closure. Comparison of the present data with MPPT powder to standard treatment suggests that the speed of healing using MPPT was improved. Further examination is required to determine if this reduces dressing changes, nursing time, and financial cost.

  12. A High Efficiency Boost Converter with MPPT Scheme for Low Voltage Thermoelectric Energy Harvesting

    NASA Astrophysics Data System (ADS)

    Guan, Mingjie; Wang, Kunpeng; Zhu, Qingyuan; Liao, Wei-Hsin

    2016-11-01

    Using thermoelectric elements to harvest energy from heat has been of great interest during the last decade. This paper presents a direct current-direct current (DC-DC) boost converter with a maximum power point tracking (MPPT) scheme for low input voltage thermoelectric energy harvesting applications. Zero current switch technique is applied in the proposed MPPT scheme. Theoretical analysis on the converter circuits is explored to derive the equations for parameters needed in the design of the boost converter. Simulations and experiments are carried out to verify the theoretical analysis and equations. A prototype of the designed converter is built using discrete components and a low-power microcontroller. The results show that the designed converter can achieve a high efficiency at low input voltage. The experimental efficiency of the designed converter is compared with a commercial converter solution. It is shown that the designed converter has a higher efficiency than the commercial solution in the considered voltage range.

  13. Comparative Analysis of Reduced-Rule Compressed Fuzzy Logic Control and Incremental Conductance MPPT Methods

    NASA Astrophysics Data System (ADS)

    Kandemir, Ekrem; Borekci, Selim; Cetin, Numan S.

    2018-04-01

    Photovoltaic (PV) power generation has been widely used in recent years, with techniques for increasing the power efficiency representing one of the most important issues. The available maximum power of a PV panel is dependent on environmental conditions such as solar irradiance and temperature. To extract the maximum available power from a PV panel, various maximum-power-point tracking (MPPT) methods are used. In this work, two different MPPT methods were implemented for a 150-W PV panel. The first method, known as incremental conductance (Inc. Cond.) MPPT, determines the maximum power by measuring the derivative of the PV voltage and current. The other method is based on reduced-rule compressed fuzzy logic control (RR-FLC), using which it is relatively easier to determine the maximum power because a single input variable is used to reduce computing loads. In this study, a 150-W PV panel system model was realized using these MPPT methods in MATLAB and the results compared. According to the simulation results, the proposed RR-FLC-based MPPT could increase the response rate and tracking accuracy by 4.66% under standard test conditions.

  14. Microwatt power consumption maximum power point tracking circuit using an analogue differentiator for piezoelectric energy harvesting

    NASA Astrophysics Data System (ADS)

    Chew, Z. J.; Zhu, M.

    2015-12-01

    A maximum power point tracking (MPPT) scheme by tracking the open-circuit voltage from a piezoelectric energy harvester using a differentiator is presented in this paper. The MPPT controller is implemented by using a low-power analogue differentiator and comparators without the need of a sensing circuitry and a power hungry controller. This proposed MPPT circuit is used to control a buck converter which serves as a power management module in conjunction with a full-wave bridge diode rectifier. Performance of this MPPT control scheme is verified by using the prototyped circuit to track the maximum power point of a macro-fiber composite (MFC) as the piezoelectric energy harvester. The MFC was bonded on a composite material and the whole specimen was subjected to various strain levels at frequency from 10 to 100 Hz. Experimental results showed that the implemented full analogue MPPT controller has a tracking efficiency between 81% and 98.66% independent of the load, and consumes an average power of 3.187 μW at 3 V during operation.

  15. Design and simulation of maximum power point tracking (MPPT) system on solar module system using constant voltage (CV) method

    NASA Astrophysics Data System (ADS)

    Bhatara, Sevty Satria; Iskandar, Reza Fauzi; Kirom, M. Ramdlan

    2016-02-01

    Solar energy is one of renewable energy resource where needs a photovoltaic module to convert it into electrical energy. One of the problems on solar energy conversion is the process of battery charging. To improve efficiency of energy conversion, PV system needs another control method on battery charging called maximum power point tracking (MPPT). This paper report the study on charging optimation using constant voltage (CV) method. This method has a function of determining output voltage of the PV system on maximal condition, so PV system will always produce a maximal energy. A model represented a PV system with and without MPPT was developed using Simulink. PV system simulation showed a different outcome energy when different solar radiation and numbers of solar module were applied in the model. On the simulation of solar radiation 1000 W/m2, PV system with MPPT produces 252.66 Watt energy and PV system without MPPT produces 252.66 Watt energy. The larger the solar radiation, the greater the energy of PV modules was produced.

  16. Lightweight DC-DC Converter with Partial Power Processing and MPPT for a Solar Powered Aircraft

    NASA Astrophysics Data System (ADS)

    Diab-Marzouk, Ahmad

    A lightweight dc-dc partial power processing converter is demonstrated for solar aerospace applications. A system-level model is conceived to determine conformity to payload and target distance objectives, with the Solarship aircraft used as an application example. The concept of partial power processing is utilized to realize a high efficiency lightweight converter that performs Max Peak Power Tracking (MPPT) to transfer power from the aircraft solar array to the high-voltage battery bus. The isolated Cuk is determined to be a suitable converter topology for the application. A small-signal model is derived for control design. The operation of a 400V, 2.7 kW prototype is verified at high frequency (200 kHz), high efficiency (> 98%), small mass (0.604 kg), and uses no electrolytic capacitors. MPPT operation is verified on a 376 V commercial solar installation at The University of Toronto. The prototype serves as an enabling technology for solar aerospace applications.

  17. A Novel Technique for Maximum Power Point Tracking of a Photovoltaic Based on Sensing of Array Current Using Adaptive Neuro-Fuzzy Inference System (ANFIS)

    NASA Astrophysics Data System (ADS)

    El-Zoghby, Helmy M.; Bendary, Ahmed F.

    2016-10-01

    Maximum Power Point Tracking (MPPT) is now widely used method in increasing the photovoltaic (PV) efficiency. The conventional MPPT methods have many problems concerning the accuracy, flexibility and efficiency. The MPP depends on the PV temperature and solar irradiation that randomly varied. In this paper an artificial intelligence based controller is presented through implementing of an Adaptive Neuro-Fuzzy Inference System (ANFIS) to obtain maximum power from PV. The ANFIS inputs are the temperature and cell current, and the output is optimal voltage at maximum power. During operation the trained ANFIS senses the PV current using suitable sensor and also senses the temperature to determine the optimal operating voltage that corresponds to the current at MPP. This voltage is used to control the boost converter duty cycle. The MATLAB simulation results shows the effectiveness of the ANFIS with sensing the PV current in obtaining the MPPT from the PV.

  18. Issues regarding the usage of MPPT techniques in micro grid systems

    NASA Astrophysics Data System (ADS)

    Szeidert, I.; Filip, I.; Dragan, F.; Gal, A.

    2018-01-01

    The main objective of the control strategies applied at hybrid micro grid systems (wind/hydro/solar), that function based on maximum power point tracking (MPPT) techniques is to improve the conversion system’s efficiency and to preserve the quality of the generated electrical energy (voltage and power factor). One of the main goals of maximum power point tracking strategy is to achieve the harvesting of the maximal possible energy within a certain time period. In order to implement the control strategies for micro grid, there are typically required specific transducers (sensor for wind speed, optical rotational transducers, etc.). In the technical literature, several variants of the MPPT techniques are presented and particularized at some applications (wind energy conversion systems, solar systems, hydro plants, micro grid hybrid systems). The maximum power point tracking implementations are mainly based on two-level architecture. The lower level controls the main variable and the superior level represents the MPPT control structure. The paper presents micro grid structures developed at Politehnica University Timisoara (PUT) within the frame of a research grant. The paper is focused on the application of MPPT strategies on hybrid micro grid systems. There are presented several structures and control strategies and are highlighted their advantages and disadvantages, together with practical implementation guidelines.

  19. Design of New Power Management Circuit for Light Energy Harvesting System

    PubMed Central

    Jafer, Issa; Stack, Paul; MacNamee, Kevin

    2016-01-01

    Nowadays, it can be observed that Wireless Sensors Networks (WSN) are taking increasingly vital roles in many applications, such as building energy monitoring and control, which is the focus of the work in this paper. However, the main challenging issue with adopting WSN technology is the use of power sources such as batteries, which have a limited lifetime. A smart solution that could tackle this problem is using Energy Harvesting technology. The work in this paper will be focused on proposing a new power management design through harvesting indoor light intensity. The new approach is inspired by the use of the Fractional Open Circuit Voltage based Maximum Power Point tracking (MPPT) concept for sub mw Photo Voltaic (PV) cells. The new design adopts two main features: First, it minimizes the power consumed by the power management section; and second, it maximizes the MPPT-converted output voltage and consequently improves the efficiency of the power conversion in the sub mw power level. The new experimentally-tested design showed an improvement of 81% in the efficiency of MPPT conversion using 0.5 mW input power in comparison with the other presented solutions that showed less efficiency with higher input power. PMID:26907300

  20. Comparison of four MPPT techniques for PV systems

    NASA Astrophysics Data System (ADS)

    Atik, L.; Petit, P.; Sawicki, J. P.; Ternifi, Z. T.; Bachir, G.; Aillerie, M.

    2016-07-01

    The working behavior of a module / PV array is non-linear and highly dependent on working conditions. As a given condition, there is only one point at which the level of available power at its output is maximum. This point varies with time, enlightenment and temperature. To ensure optimum operation, the use of MPPT control allows us to extract the maximum power. This paper presents a comparative study of four widely-adopted MPPT algorithms, such as Perturb and Observe, Incremental Conductance, Measurements of the variation of the open circuit voltage or of the short-circuit current. Their performance is evaluated using, for all these techniques. In particular, this study compares the behaviors of each technique in presence of solar irradiation variations and temperature fluctuations. These MPPT techniques will be compared using the Matlab / Simulink tool.

  1. Sliding mode controller for a photovoltaic pumping system

    NASA Astrophysics Data System (ADS)

    ElOugli, A.; Miqoi, S.; Boutouba, M.; Tidhaf, B.

    2017-03-01

    In this paper, a sliding mode control scheme (SMC) for maximum power point tracking controller for a photovoltaic pumping system, is proposed. The main goal is to maximize the flow rate for a water pump, by forcing the photovoltaic system to operate in its MPP, to obtain the maximum power that a PV system can deliver.And this, through the intermediary of a sliding mode controller to track and control the MPP by overcoming the power oscillation around the operating point, which appears in most implemented MPPT techniques. The sliding mode control approach is recognized as one of the efficient and powerful tools for nonlinear systems under uncertainty conditions.The proposed controller with photovoltaic pumping system is designed and simulated using MATLAB/SIMULINK environment. In addition, to evaluate its performances, a classical MPPT algorithm using perturb and observe (P&O) has been used for the same system to compare to our controller. Simulation results are shown.

  2. Comparison of four MPPT techniques for PV systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Atik, L., E-mail: lotfi.atik@univ-usto.dz; Ternifi, Z. T.; Université de Lorraine, LMOPS, EA 4423, 57070 Metz

    2016-07-25

    The working behavior of a module / PV array is non-linear and highly dependent on working conditions. As a given condition, there is only one point at which the level of available power at its output is maximum. This point varies with time, enlightenment and temperature. To ensure optimum operation, the use of MPPT control allows us to extract the maximum power. This paper presents a comparative study of four widely-adopted MPPT algorithms, such as Perturb and Observe, Incremental Conductance, Measurements of the variation of the open circuit voltage or of the short-circuit current. Their performance is evaluated using, formore » all these techniques. In particular, this study compares the behaviors of each technique in presence of solar irradiation variations and temperature fluctuations. These MPPT techniques will be compared using the Matlab / Simulink tool.« less

  3. Increased Energy Delivery for Parallel Battery Packs with No Regulated Bus

    NASA Astrophysics Data System (ADS)

    Hsu, Chung-Ti

    In this dissertation, a new approach to paralleling different battery types is presented. A method for controlling charging/discharging of different battery packs by using low-cost bi-directional switches instead of DC-DC converters is proposed. The proposed system architecture, algorithms, and control techniques allow batteries with different chemistry, voltage, and SOC to be properly charged and discharged in parallel without causing safety problems. The physical design and cost for the energy management system is substantially reduced. Additionally, specific types of failures in the maximum power point tracking (MPPT) in a photovoltaic (PV) system when tracking only the load current of a DC-DC converter are analyzed. The periodic nonlinear load current will lead MPPT realized by the conventional perturb and observe (P&O) algorithm to be problematic. A modified MPPT algorithm is proposed and it still only requires typically measured signals, yet is suitable for both linear and periodic nonlinear loads. Moreover, for a modular DC-DC converter using several converters in parallel, the input power from PV panels is processed and distributed at the module level. Methods for properly implementing distributed MPPT are studied. A new approach to efficient MPPT under partial shading conditions is presented. The power stage architecture achieves fast input current change rate by combining a current-adjustable converter with a few converters operating at a constant current.

  4. Random Forest-Based Approach for Maximum Power Point Tracking of Photovoltaic Systems Operating under Actual Environmental Conditions.

    PubMed

    Shareef, Hussain; Mutlag, Ammar Hussein; Mohamed, Azah

    2017-01-01

    Many maximum power point tracking (MPPT) algorithms have been developed in recent years to maximize the produced PV energy. These algorithms are not sufficiently robust because of fast-changing environmental conditions, efficiency, accuracy at steady-state value, and dynamics of the tracking algorithm. Thus, this paper proposes a new random forest (RF) model to improve MPPT performance. The RF model has the ability to capture the nonlinear association of patterns between predictors, such as irradiance and temperature, to determine accurate maximum power point. A RF-based tracker is designed for 25 SolarTIFSTF-120P6 PV modules, with the capacity of 3 kW peak using two high-speed sensors. For this purpose, a complete PV system is modeled using 300,000 data samples and simulated using the MATLAB/SIMULINK package. The proposed RF-based MPPT is then tested under actual environmental conditions for 24 days to validate the accuracy and dynamic response. The response of the RF-based MPPT model is also compared with that of the artificial neural network and adaptive neurofuzzy inference system algorithms for further validation. The results show that the proposed MPPT technique gives significant improvement compared with that of other techniques. In addition, the RF model passes the Bland-Altman test, with more than 95 percent acceptability.

  5. Random Forest-Based Approach for Maximum Power Point Tracking of Photovoltaic Systems Operating under Actual Environmental Conditions

    PubMed Central

    Shareef, Hussain; Mohamed, Azah

    2017-01-01

    Many maximum power point tracking (MPPT) algorithms have been developed in recent years to maximize the produced PV energy. These algorithms are not sufficiently robust because of fast-changing environmental conditions, efficiency, accuracy at steady-state value, and dynamics of the tracking algorithm. Thus, this paper proposes a new random forest (RF) model to improve MPPT performance. The RF model has the ability to capture the nonlinear association of patterns between predictors, such as irradiance and temperature, to determine accurate maximum power point. A RF-based tracker is designed for 25 SolarTIFSTF-120P6 PV modules, with the capacity of 3 kW peak using two high-speed sensors. For this purpose, a complete PV system is modeled using 300,000 data samples and simulated using the MATLAB/SIMULINK package. The proposed RF-based MPPT is then tested under actual environmental conditions for 24 days to validate the accuracy and dynamic response. The response of the RF-based MPPT model is also compared with that of the artificial neural network and adaptive neurofuzzy inference system algorithms for further validation. The results show that the proposed MPPT technique gives significant improvement compared with that of other techniques. In addition, the RF model passes the Bland–Altman test, with more than 95 percent acceptability. PMID:28702051

  6. Optimized MPPT-based converter for TEG energy harvester to power wireless sensor and monitoring system in nuclear power plant

    NASA Astrophysics Data System (ADS)

    Xing, Shaoxu; Anakok, Isil; Zuo, Lei

    2017-04-01

    Accidents like Fukushima Disasters push people to improve the monitoring systems for the nuclear power plants. Thus, various types of energy harvesters are designed to power these systems and the Thermoelectric Generator (TEG) energy harvester is one of them. In order to enhance the amount of harvested power and the system efficiency, the power management stage needs to be carefully designed. In this paper, a power converter with optimized Maximum Power Point Tracking (MPPT) is proposed for the TEG Energy Harvester to power the wireless sensor network in nuclear power plant. The TEG Energy Harvester is installed on the coolant pipe of the nuclear plant and harvests energy from its heat energy while the power converter with optimized MPPT can make the TEG Energy Harvester output the maximum power, quickly response to the voltage change and provide sufficient energy for wireless sensor system to monitor the operation of the nuclear power plant. Due to the special characteristics of the Single-Ended Primary Inductor Converter (SEPIC) when it is working in the Discontinuous Inductor Current Mode (DICM) and Continuous Conduction Mode (CCM), the MPPT method presented in this paper would be able to control the converter to achieve the maximum output power in any working conditions of the TEG system with a simple circuit. The optimized MPPT algorithm will significantly reduce the cost and simplify the system as well as achieve a good performance. Experiment test results have shown that, comparing to a fixed- duty-cycle SEPIC which is specifically designed for the working on the secondary coolant loop in nuclear power plant, the optimized MPPT algorithm increased the output power by 55%.

  7. Indirect adaptive soft computing based wavelet-embedded control paradigms for WT/PV/SOFC in a grid/charging station connected hybrid power system.

    PubMed

    Mumtaz, Sidra; Khan, Laiq; Ahmed, Saghir; Bader, Rabiah

    2017-01-01

    This paper focuses on the indirect adaptive tracking control of renewable energy sources in a grid-connected hybrid power system. The renewable energy systems have low efficiency and intermittent nature due to unpredictable meteorological conditions. The domestic load and the conventional charging stations behave in an uncertain manner. To operate the renewable energy sources efficiently for harvesting maximum power, instantaneous nonlinear dynamics should be captured online. A Chebyshev-wavelet embedded NeuroFuzzy indirect adaptive MPPT (maximum power point tracking) control paradigm is proposed for variable speed wind turbine-permanent synchronous generator (VSWT-PMSG). A Hermite-wavelet incorporated NeuroFuzzy indirect adaptive MPPT control strategy for photovoltaic (PV) system to extract maximum power and indirect adaptive tracking control scheme for Solid Oxide Fuel Cell (SOFC) is developed. A comprehensive simulation test-bed for a grid-connected hybrid power system is developed in Matlab/Simulink. The robustness of the suggested indirect adaptive control paradigms are evaluated through simulation results in a grid-connected hybrid power system test-bed by comparison with conventional and intelligent control techniques. The simulation results validate the effectiveness of the proposed control paradigms.

  8. Indirect adaptive soft computing based wavelet-embedded control paradigms for WT/PV/SOFC in a grid/charging station connected hybrid power system

    PubMed Central

    Khan, Laiq; Ahmed, Saghir; Bader, Rabiah

    2017-01-01

    This paper focuses on the indirect adaptive tracking control of renewable energy sources in a grid-connected hybrid power system. The renewable energy systems have low efficiency and intermittent nature due to unpredictable meteorological conditions. The domestic load and the conventional charging stations behave in an uncertain manner. To operate the renewable energy sources efficiently for harvesting maximum power, instantaneous nonlinear dynamics should be captured online. A Chebyshev-wavelet embedded NeuroFuzzy indirect adaptive MPPT (maximum power point tracking) control paradigm is proposed for variable speed wind turbine-permanent synchronous generator (VSWT-PMSG). A Hermite-wavelet incorporated NeuroFuzzy indirect adaptive MPPT control strategy for photovoltaic (PV) system to extract maximum power and indirect adaptive tracking control scheme for Solid Oxide Fuel Cell (SOFC) is developed. A comprehensive simulation test-bed for a grid-connected hybrid power system is developed in Matlab/Simulink. The robustness of the suggested indirect adaptive control paradigms are evaluated through simulation results in a grid-connected hybrid power system test-bed by comparison with conventional and intelligent control techniques. The simulation results validate the effectiveness of the proposed control paradigms. PMID:28877191

  9. UNISAT-3 Power System

    NASA Astrophysics Data System (ADS)

    Santoni, Fabio; Piergentili, Fabrizio; Bulgarelli, Fabio; Graziani, Filippo

    2005-05-01

    An overview of the UNISAT-3 microsatellite power subsystem is given. This is an educational, low weight and low cost microsatellite designed, built, launched and operated in space by students and professors of Scuola di Ingegneria Aerospaziale, at University of Rome "La Sapienza". The satellite power system is based on terrestrial technology solar arrays and NiCd batteries. The microsatellite hosts other solar arrays, including multi-junction solar cells and mono- crystalline silicon high efficiency solar cells, in order to compare their behaviour in orbit. Moreover a MPPT (Maximum Power Point Tracking ) system has been designed and tested, and it is a technological payload of UNISAT-3. The MPPT design follows the studies performed in the field of solar powered racing cars, with modifications to make the system suitable for use in space. The system design, numerical simulation and hardware ground testing are described in the paper. The experiment and the performance evaluation criterion are described, together with the preliminary results of the first eight months of operation in orbit.

  10. A Miniaturized 0.78-mW/cm2 Autonomous Thermoelectric Energy-Harvesting Platform for Biomedical Sensors.

    PubMed

    Rozgic, Dejan; Markovic, Dejan

    2017-08-01

    In order to use thermoelectric energy harvesters (TEHs) as a truly autonomous energy source for size-limited sensing applications, it is essential to improve the power conversion efficiency and energy density. This study presents a thin-film, array-based TEH with a surface area of 0.83 cm 2 . The TEH autonomously supplies a power management IC fabricated in a 65-nm CMOS technology. The IC utilizes a single-inductor topology with integrated analog maximum power point tracking (MPPT), resulting in a 68% peak end-to-end efficiency (92% converter efficiency) and less than 20-ms MPPT. In an in-vivo test, a 645-μW regulated output power (effective 3.5 K of temperature gradient) was harvested from a rat implanted with our TEH, demonstrating true energy independence in a real environment while showing a 7.9 × improvement in regulated power density compared to the state-of-the-art. The system showed autonomous operation down to 65-mV TEH input.

  11. External Resistances Applied to MFC Affect Core Microbiome and Swine Manure Treatment Efficiencies

    PubMed Central

    Vilajeliu-Pons, Anna; Bañeras, Lluis; Puig, Sebastià; Molognoni, Daniele; Vilà-Rovira, Albert; Hernández-del Amo, Elena; Balaguer, Maria D.; Colprim, Jesús

    2016-01-01

    Microbial fuel cells (MFCs) can be designed to combine water treatment with concomitant electricity production. Animal manure treatment has been poorly explored using MFCs, and its implementation at full-scale primarily relies on the bacterial distribution and activity within the treatment cell. This study reports the bacterial community changes at four positions within the anode of two almost identically operated MFCs fed swine manure. Changes in the microbiome structure are described according to the MFC fluid dynamics and the application of a maximum power point tracking system (MPPT) compared to a fixed resistance system (Ref-MFC). Both external resistance and cell hydrodynamics are thought to heavily influence MFC performance. The microbiome was characterised both quantitatively (qPCR) and qualitatively (454-pyrosequencing) by targeting bacterial 16S rRNA genes. The diversity of the microbial community in the MFC biofilm was reduced and differed from the influent swine manure. The adopted electric condition (MPPT vs fixed resistance) was more relevant than the fluid dynamics in shaping the MFC microbiome. MPPT control positively affected bacterial abundance and promoted the selection of putatively exoelectrogenic bacteria in the MFC core microbiome (Sedimentibacter sp. and gammaproteobacteria). These differences in the microbiome may be responsible for the two-fold increase in power production achieved by the MPPT-MFC compared to the Ref-MFC. PMID:27701451

  12. A comparative study of artificial intelligent-based maximum power point tracking for photovoltaic systems

    NASA Astrophysics Data System (ADS)

    Hussain Mutlag, Ammar; Mohamed, Azah; Shareef, Hussain

    2016-03-01

    Maximum power point tracking (MPPT) is normally required to improve the performance of photovoltaic (PV) systems. This paper presents artificial intelligent-based maximum power point tracking (AI-MPPT) by considering three artificial intelligent techniques, namely, artificial neural network (ANN), adaptive neuro fuzzy inference system with seven triangular fuzzy sets (7-tri), and adaptive neuro fuzzy inference system with seven gbell fuzzy sets. The AI-MPPT is designed for the 25 SolarTIFSTF-120P6 PV panels, with the capacity of 3 kW peak. A complete PV system is modelled using 300,000 data samples and simulated in the MATLAB/SIMULINK. The AI-MPPT has been tested under real environmental conditions for two days from 8 am to 18 pm. The results showed that the ANN based MPPT gives the most accurate performance and then followed by the 7-tri-based MPPT.

  13. Maximum power point tracking for photovoltaic applications by using two-level DC/DC boost converter

    NASA Astrophysics Data System (ADS)

    Moamaei, Parvin

    Recently, photovoltaic (PV) generation is becoming increasingly popular in industrial applications. As a renewable and alternative source of energy they feature superior characteristics such as being clean and silent along with less maintenance problems compared to other sources of the energy. In PV generation, employing a Maximum Power Point Tracking (MPPT) method is essential to obtain the maximum available solar energy. Among several proposed MPPT techniques, the Perturbation and Observation (P&O;) and Model Predictive Control (MPC) methods are adopted in this work. The components of the MPPT control system which are P&O; and MPC algorithms, PV module and high gain DC-DC boost converter are simulated in MATLAB Simulink. They are evaluated theoretically under rapidly and slowly changing of solar irradiation and temperature and their performance is shown by the simulation results, finally a comprehensive comparison is presented.

  14. 76 FR 41556 - Petition for Waiver of Compliance

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-14

    ... Cannon at MP-PT 118.9 near Duncannon, PA to CP Solomon at MP-PT 352.5 near Pittsburgh, PA, with the... between CP Bloom at MP-PT 351.6 near Pittsburg, PA and CP Solomon. Operations on the Fort Wayne Line...

  15. An Efficient Modulation Strategy for Cascaded Photovoltaic Systems Suffering From Module Mismatch

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Cheng; Zhang, Kai; Xiong, Jian

    Modular multilevel cascaded converter (MMCC) is a promising technique for medium/high-voltage high-power photovoltaic systems due to its modularity, scalability, and capability of distributed maximum power point tracking (MPPT) etc. However, distributed MPPT under module-mismatch might polarize the distribution of ac output voltages as well as the dc-link voltages among the modules, distort grid currents, and even cause system instability. For the better acceptance in practical applications, such issues need to be well addressed. Based on mismatch degree that is defined to consider both active power distribution and maximum modulation index, this paper presents an efficient modulation strategy for a cascaded-H-bridge-basedmore » MMCC under module mismatch. It can operate in loss-reducing mode or range-extending mode. By properly switching between the two modes, performance indices such as system efficiency, grid current quality, and balance of dc voltages, can be well coordinated. In this way, the MMCC system can maintain high-performance over a wide range of operating conditions. As a result, effectiveness of the proposed modulation strategy is proved with experiments.« less

  16. An Efficient Modulation Strategy for Cascaded Photovoltaic Systems Suffering From Module Mismatch

    DOE PAGES

    Wang, Cheng; Zhang, Kai; Xiong, Jian; ...

    2017-09-26

    Modular multilevel cascaded converter (MMCC) is a promising technique for medium/high-voltage high-power photovoltaic systems due to its modularity, scalability, and capability of distributed maximum power point tracking (MPPT) etc. However, distributed MPPT under module-mismatch might polarize the distribution of ac output voltages as well as the dc-link voltages among the modules, distort grid currents, and even cause system instability. For the better acceptance in practical applications, such issues need to be well addressed. Based on mismatch degree that is defined to consider both active power distribution and maximum modulation index, this paper presents an efficient modulation strategy for a cascaded-H-bridge-basedmore » MMCC under module mismatch. It can operate in loss-reducing mode or range-extending mode. By properly switching between the two modes, performance indices such as system efficiency, grid current quality, and balance of dc voltages, can be well coordinated. In this way, the MMCC system can maintain high-performance over a wide range of operating conditions. As a result, effectiveness of the proposed modulation strategy is proved with experiments.« less

  17. Design of Solar Street Lamp Control System Based on MPPT

    NASA Astrophysics Data System (ADS)

    Cui, Fengying

    This paper proposes a new solar street lamp control system which is composed of photovoltaic cell, controller, battery and load. In this system controller as the key part applies the microchip to achieve many functions. According to the nonlinear output characteristics of solar cell and the influence of environment, it uses the perturbation and observation (P&O) method to realize the maximum power point tracking (MPPT) and promotes the efficiency. In order to prolong the battery life the pulse width modulation (PWM) charge mode is selected to control the battery capacity and provent the battery from the state of over-charge and over-discharge. Meanwhile the function of temperature compensation, charge and discharge protection are set to improve the running safety and stability.

  18. Design and experimental evaluation on an advanced multisource energy harvesting system for wireless sensor nodes.

    PubMed

    Li, Hao; Zhang, Gaofei; Ma, Rui; You, Zheng

    2014-01-01

    An effective multisource energy harvesting system is presented as power supply for wireless sensor nodes (WSNs). The advanced system contains not only an expandable power management module including control of the charging and discharging process of the lithium polymer battery but also an energy harvesting system using the maximum power point tracking (MPPT) circuit with analog driving scheme for the collection of both solar and vibration energy sources. Since the MPPT and the power management module are utilized, the system is able to effectively achieve a low power consumption. Furthermore, a super capacitor is integrated in the system so that current fluctuations of the lithium polymer battery during the charging and discharging processes can be properly reduced. In addition, through a simple analog switch circuit with low power consumption, the proposed system can successfully switch the power supply path according to the ambient energy sources and load power automatically. A practical WSNs platform shows that efficiency of the energy harvesting system can reach about 75-85% through the 24-hour environmental test, which confirms that the proposed system can be used as a long-term continuous power supply for WSNs.

  19. Design and Experimental Evaluation on an Advanced Multisource Energy Harvesting System for Wireless Sensor Nodes

    PubMed Central

    Li, Hao; Zhang, Gaofei; Ma, Rui; You, Zheng

    2014-01-01

    An effective multisource energy harvesting system is presented as power supply for wireless sensor nodes (WSNs). The advanced system contains not only an expandable power management module including control of the charging and discharging process of the lithium polymer battery but also an energy harvesting system using the maximum power point tracking (MPPT) circuit with analog driving scheme for the collection of both solar and vibration energy sources. Since the MPPT and the power management module are utilized, the system is able to effectively achieve a low power consumption. Furthermore, a super capacitor is integrated in the system so that current fluctuations of the lithium polymer battery during the charging and discharging processes can be properly reduced. In addition, through a simple analog switch circuit with low power consumption, the proposed system can successfully switch the power supply path according to the ambient energy sources and load power automatically. A practical WSNs platform shows that efficiency of the energy harvesting system can reach about 75–85% through the 24-hour environmental test, which confirms that the proposed system can be used as a long-term continuous power supply for WSNs. PMID:25032233

  20. Accurate Simulation of MPPT Methods Performance When Applied to Commercial Photovoltaic Panels

    PubMed Central

    2015-01-01

    A new, simple, and quick-calculation methodology to obtain a solar panel model, based on the manufacturers' datasheet, to perform MPPT simulations, is described. The method takes into account variations on the ambient conditions (sun irradiation and solar cells temperature) and allows fast MPPT methods comparison or their performance prediction when applied to a particular solar panel. The feasibility of the described methodology is checked with four different MPPT methods applied to a commercial solar panel, within a day, and under realistic ambient conditions. PMID:25874262

  1. Application of Copper Indium Gallium Diselenide Photovoltaic Cells to Extend the Endurance and Capabilities of the Raven RQ-11B Unmanned Aerial Vehicle

    DTIC Science & Technology

    2010-09-01

    POWER POINT TRACKER A more suitable component used in photovoltaic appli- cations is the Maximum Power Point Tracker ( MPPT ). An MPPT ... MPPT / power converter (Solar Charge Controller ) weighed 6.5-Oz, but without the casing it weighed only 3.6-Oz. We preferred to use it without the...for this test was the GV-4 Low Power Charge Controller from GENASUN used in previous the- sis work [5]. This MPPT was programmed to charge up

  2. Accurate simulation of MPPT methods performance when applied to commercial photovoltaic panels.

    PubMed

    Cubas, Javier; Pindado, Santiago; Sanz-Andrés, Ángel

    2015-01-01

    A new, simple, and quick-calculation methodology to obtain a solar panel model, based on the manufacturers' datasheet, to perform MPPT simulations, is described. The method takes into account variations on the ambient conditions (sun irradiation and solar cells temperature) and allows fast MPPT methods comparison or their performance prediction when applied to a particular solar panel. The feasibility of the described methodology is checked with four different MPPT methods applied to a commercial solar panel, within a day, and under realistic ambient conditions.

  3. Clinical relevance of the modified physical performance test versus the short physical performance battery for detecting mobility impairments in older men with peripheral arterial disease.

    PubMed

    Addison, Odessa; Kundi, Rishi; Ryan, Alice S; Goldberg, Andrew P; Patel, Richa; Lal, Brajesh K; Prior, Steven J

    2017-08-23

    The study is to compare the Modified Physical Performance Test (MPPT) and Short Physical Performance Battery (SPPB) as metrics of mobility and function in older men with peripheral arterial disease (PAD). A total of 51 men (55-87 years) with PAD underwent functional testing including the SPPB, MPPT, Walking Impairment Questionnaire (WIQ), stair ascent, and 6-min walk distance. Individuals were grouped according to SPPB and MPPT scores as not limited on either, limited only on the MPPT, or limited on both. The MPPT identified a higher proportion of patients as being functionally limited than the SPPB (p < 0.001). Men identified as limited only by the MPPT, and not the SPPB, were subsequently confirmed to have lower function on all measures compared to those not identified as limited by either the SPPB or the MPPT (p < 0.02). These findings suggest the MPPT is an appropriate measure to identify early declines in men with PAD and may identify global disability better than SPPB. Implications for rehabilitation Individuals with peripheral arterial disease have low activity levels and are at risk for a loss of independence and global disability. Early detection of decline in mobility and global function would allow for interventions before large changes in ambulatory ability or a loss of functional independence occur. This study shows the Modified Physical Performance Test may be an appropriate test to identify early decline in function in men with peripheral arterial disease.

  4. Smoothing PV System’s Output by Tuning MPPT Control

    NASA Astrophysics Data System (ADS)

    Ina, Nobuhiko; Yanagawa, Shigeyuki; Kato, Takeyoshi; Suzuoki, Yasuo

    A PV system’s output is not stable and fluctuates depending on a weather condition. Using a battery is one of the feasible ways to stabilize a PV system’s output, although it requires an additional cost and provides an additional waste of the used battery. In this paper, we propose tuning a characteristic of Maxiumum Power Point Tracking (MPPT) control for smoothing a short term change of PV system’s output during a sharp insolation fluctuation, as an approach without additional equipments. In our proposed method, when an insolation increases rapidly, the operation point of MPPT control changes to the new point where the maximum power is not generated with present insolation, so that the speed of PV system’s output increase is limited to a certain value, i. e. 1%/min. In order to evaluate the effect of our proposed method in terms of reducing the additional operation task of the electric power system, we evaluated the additional LFC capacity for a large-scale installation of PV systems. As a result, it was revealed that the additional LFC capacity is not required even if a PV system is installed by 5% of utility system, when our proposed method is applied to all PV systems.

  5. Energy-Efficient Underwater Surveillance by Means of Hybrid Aquacopters

    DTIC Science & Technology

    2014-12-01

    life-cycle analysis, photovoltaic device maximum power point tracking (MPPT), and surface treatments for antifouling of the solar cells can be...108 3. Power Conversion and Storage...15 Figure 10. Shallow Water Analysis and Forecast System product, displaying regional ocean current vectors overlaying a sea surface

  6. MPPT Algorithm Development for Laser Powered Surveillance Camera Power Supply Unit

    NASA Astrophysics Data System (ADS)

    Zhang, Yungui; Dushantha Chaminda, P. R.; Zhao, Kun; Cheng, Lin; Jiang, Yi; Peng, Kai

    2018-03-01

    Photovoltaics (PV) cells, modules which are semiconducting materials, convert light energy into electricity. Operation of a PV cell requires 3 basic features. When the light is absorbed it generate pairs of electron holes or excitons. An external circuit carrier opposite types of electrons irrespective of the source (sunlight or LASER light). The PV arrays have photovoltaic effect and the PV cells are defined as a device which has electrical characteristics: such as current, voltage and resistance. It varies when exposed to light, that the power output is depend on direct Laser-light. In this paper Laser-light to electricity by direct conversion with the use of PV cells and its concept of Band gap Energy, Series Resistance, Conversion Efficiency and Maximum Power Point Tracking (MPPT) methods [1].

  7. Implementation of Maximum Power Point Tracking (MPPT) Solar Charge Controller using Arduino

    NASA Astrophysics Data System (ADS)

    Abdelilah, B.; Mouna, A.; KouiderM’Sirdi, N.; El Hossain, A.

    2018-05-01

    the platform Arduino with a number of sensors standard can be used as components of an electronic system for acquiring measures and controls. This paper presents the design of a low-cost and effective solar charge controller. This system includes several elements such as the solar panel converter DC/DC, battery, circuit MPPT using Microcontroller, sensors, and the MPPT algorithm. The MPPT (Maximum Power Point Tracker) algorithm has been implemented using an Arduino Nano with the preferred program. The voltage and current of the Panel are taken where the program implemented will work and using this algorithm that MPP will be reached. This paper provides details on the solar charge control device at the maximum power point. The results include the change of the duty cycle with the change in load and thus mean the variation of the buck converter output voltage and current controlled by the MPPT algorithm.

  8. Study of Simple MPPT Converter Topologies for Grid Integration of Photovoltaic Systems

    NASA Astrophysics Data System (ADS)

    Zakis, Janis; Vinnikov, Dmitri

    2011-01-01

    This paper presents a study of two simple MPPT converter topologies for grid integration of photovoltaic (PV) systems. A general description and a steady state analysis of the discussed converters are presented. Main operating modes of the converters are explained. Calculations of main circuit element parameters are provided. Experimental setups of the MPPT converters with the power of 800 W were developed and verified by means of main operation waveforms. Also, experimental and theoretical boost properties of the studied topologies are compared. Finally, the integration possibilities of the presented MPPT converters with a grid side inverter are discussed and verified by simulations.

  9. A novel multi-model neuro-fuzzy-based MPPT for three-phase grid-connected photovoltaic system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chaouachi, Aymen; Kamel, Rashad M.; Nagasaka, Ken

    This paper presents a novel methodology for Maximum Power Point Tracking (MPPT) of a grid-connected 20 kW photovoltaic (PV) system using neuro-fuzzy network. The proposed method predicts the reference PV voltage guarantying optimal power transfer between the PV generator and the main utility grid. The neuro-fuzzy network is composed of a fuzzy rule-based classifier and three multi-layered feed forwarded Artificial Neural Networks (ANN). Inputs of the network (irradiance and temperature) are classified before they are fed into the appropriated ANN for either training or estimation process while the output is the reference voltage. The main advantage of the proposed methodology,more » comparing to a conventional single neural network-based approach, is the distinct generalization ability regarding to the nonlinear and dynamic behavior of a PV generator. In fact, the neuro-fuzzy network is a neural network based multi-model machine learning that defines a set of local models emulating the complex and nonlinear behavior of a PV generator under a wide range of operating conditions. Simulation results under several rapid irradiance variations proved that the proposed MPPT method fulfilled the highest efficiency comparing to a conventional single neural network and the Perturb and Observe (P and O) algorithm dispositive. (author)« less

  10. Research of MPPT for photovoltaic generation based on two-dimensional cloud model

    NASA Astrophysics Data System (ADS)

    Liu, Shuping; Fan, Wei

    2013-03-01

    The cloud model is a mathematical representation to fuzziness and randomness in linguistic concepts. It represents a qualitative concept with expected value Ex, entropy En and hyper entropy He, and integrates the fuzziness and randomness of a linguistic concept in a unified way. This model is a new method for transformation between qualitative and quantitative in the knowledge. This paper is introduced MPPT (maximum power point tracking, MPPT) controller based two- dimensional cloud model through analysis of auto-optimization MPPT control of photovoltaic power system and combining theory of cloud model. Simulation result shows that the cloud controller is simple and easy, directly perceived through the senses, and has strong robustness, better control performance.

  11. Control strategy of grid-connected photovoltaic generation system based on GMPPT method

    NASA Astrophysics Data System (ADS)

    Wang, Zhongfeng; Zhang, Xuyang; Hu, Bo; Liu, Jun; Li, Ligang; Gu, Yongqiang; Zhou, Bowen

    2018-02-01

    There are multiple local maximum power points when photovoltaic (PV) array runs under partial shading condition (PSC).However, the traditional maximum power point tracking (MPPT) algorithm might be easily trapped in local maximum power points (MPPs) and cannot find the global maximum power point (GMPP). To solve such problem, a global maximum power point tracking method (GMPPT) is improved, combined with traditional MPPT method and particle swarm optimization (PSO) algorithm. Under different operating conditions of PV cells, different tracking algorithms are used. When the environment changes, the improved PSO algorithm is adopted to realize the global optimal search, and the variable step incremental conductance (INC) method is adopted to achieve MPPT in optimal local location. Based on the simulation model of the PV grid system built in Matlab/Simulink, comparative analysis of the tracking effect of MPPT by the proposed control algorithm and the traditional MPPT method under the uniform solar condition and PSC, validate the correctness, feasibility and effectiveness of the proposed control strategy.

  12. A new maximum power tracking in PV system during partially shaded conditions based on shuffled frog leap algorithm

    NASA Astrophysics Data System (ADS)

    Sridhar, R.; Jeevananthan, S.; Dash, S. S.; Vishnuram, Pradeep

    2017-05-01

    Maximum Power Point Trackers (MPPTs) are power electronic conditioners used in photovoltaic (PV) system to ensure that PV structures feed maximum power for the given ambient temperature and sun's irradiation. When the PV panels are shaded by a fraction due to any environment hindrances then, conventional MPPT trackers may fail in tracking the appropriate peak power as there will be multi power peaks. In this work, a shuffled frog leap algorithm (SFLA) is proposed and it successfully identifies the global maximum power point among other local maxima. The SFLA MPPT is compared with a well-entrenched conventional perturb and observe (P&O) MPPT algorithm and a global search particle swarm optimisation (PSO) MPPT. The simulation results reveal that the proposed algorithm is highly advantageous than P&O, as it tracks nearly 30% more power for a given shading pattern. The credible nature of the proposed SFLA is ensured when it outplays PSO MPPT in convergence. The whole system is realised in MATLAB/Simulink environment.

  13. Utilizing Maximum Power Point Trackers in Parallel to Maximize the Power Output of a Solar (Photovoltaic) Array

    DTIC Science & Technology

    2012-12-01

    photovoltaic (PV) system to use a maximum power point tracker ( MPPT ) to increase... photovoltaic (PV) system to use a maximum power point tracker ( MPPT ) to increase the power output of the solar array. Currently, most military... MPPT ) is an optimizing circuit that is used in conjunction with photovoltaic (PV) arrays to achieve the maximum delivery of power from the array

  14. Magnification of starting torques of dc motors by maximum power point trackers in photovoltaic systems

    NASA Technical Reports Server (NTRS)

    Appelbaum, Joseph; Singer, S.

    1989-01-01

    Direct current (dc) motors are used in terrestrial photovoltaic (PV) systems such as in water-pumping systems for irrigation and water supply. Direct current motors may also be used for space applications. Simple and low weight systems including dc motors may be of special interest in space where the motors are directly coupled to the solar cell array (with no storage). The system will operate only during times when sufficient insolation is available. An important performance characteristic of electric motors is the starting to rated torque ratio. Different types of dc motors have different starting torque ratios. These ratios are dictated by the size of solar cell array, and the developed motor torque may not be sufficient to overcome the load starting torque. By including a maximum power point tracker (MPPT) in the PV system, the starting to rated torque ratio will increase, the amount of which depends on the motor type. The starting torque ratio is calculated for the permanent magnet, series and shunt excited dc motors when powered by solar cell arrays for two cases: with and without MPPT's. Defining a motor torque magnification by the ratio of the motor torque with an MPPT to the motor torque without an MPPT, a magnification of 3 was obtained for the permanent magnet motor and a magnification of 7 for both the series and shunt motors. The effect of the variation of solar insolation on the motor starting torque was covered. All motor types are less sensitive to insolation variation in systems including MPPT's as compared to systems with MPPT's. The analysis of this paper will assist the PV system designed to determine whether or not to include an MPPT in the system for a specific motor type.

  15. A state-of-the-art compact SiC photovoltaic inverter with maximum power point tracking function

    NASA Astrophysics Data System (ADS)

    Ando, Yuji; Oku, Takeo; Yasuda, Masashi; Ushijima, Kazufumi; Matsuo, Hiroshi; Murozono, Mikio

    2018-01-01

    We have developed a 150-W SiC-based photovoltaic (PV)-inverter with the maximum power point tracking (MPPT) function. The newly developed inverter achieved a state-of-the-art combination of the weight (0.79 kg) and the volume (790 mm3) as a 150-250 W class PV-inverter. As compared to the original version that we have previously reported, the weight and volume were decreased by 37% and 38%, respectively. This compactness originated from the optimized circuit structure and the increased density of a wiring circuit. Conversion efficiencies of the MPPT charge controller and the direct current (DC)-alternating current (AC) converter reached 96.4% and 87.6%, respectively. These efficiency values are comparable to those for the original version. We have developed a PV power generation system consisting of this inverter, a spherical Si solar cell module, and a 15-V Li-ion laminated battery. The total weight of the system was below 6 kg. The developed system exhibited stable output power characteristics, even when the weather conditions were fluctuated. These compactness, high efficiencies, and excellent stability clearly indicated the feasibility of SiC power devices even for sub-kW class PV power generation systems.

  16. Flow Control in Wells Turbines for Harnessing Maximum Wave Power.

    PubMed

    Lekube, Jon; Garrido, Aitor J; Garrido, Izaskun; Otaola, Erlantz; Maseda, Javier

    2018-02-10

    Oceans, and particularly waves, offer a huge potential for energy harnessing all over the world. Nevertheless, the performance of current energy converters does not yet allow us to use the wave energy efficiently. However, new control techniques can improve the efficiency of energy converters. In this sense, the plant sensors play a key role within the control scheme, as necessary tools for parameter measuring and monitoring that are then used as control input variables to the feedback loop. Therefore, the aim of this work is to manage the rotational speed control loop in order to optimize the output power. With the help of outward looking sensors, a Maximum Power Point Tracking (MPPT) technique is employed to maximize the system efficiency. Then, the control decisions are based on the pressure drop measured by pressure sensors located along the turbine. A complete wave-to-wire model is developed so as to validate the performance of the proposed control method. For this purpose, a novel sensor-based flow controller is implemented based on the different measured signals. Thus, the performance of the proposed controller has been analyzed and compared with a case of uncontrolled plant. The simulations demonstrate that the flow control-based MPPT strategy is able to increase the output power, and they confirm both the viability and goodness.

  17. Flow Control in Wells Turbines for Harnessing Maximum Wave Power

    PubMed Central

    Garrido, Aitor J.; Garrido, Izaskun; Otaola, Erlantz; Maseda, Javier

    2018-01-01

    Oceans, and particularly waves, offer a huge potential for energy harnessing all over the world. Nevertheless, the performance of current energy converters does not yet allow us to use the wave energy efficiently. However, new control techniques can improve the efficiency of energy converters. In this sense, the plant sensors play a key role within the control scheme, as necessary tools for parameter measuring and monitoring that are then used as control input variables to the feedback loop. Therefore, the aim of this work is to manage the rotational speed control loop in order to optimize the output power. With the help of outward looking sensors, a Maximum Power Point Tracking (MPPT) technique is employed to maximize the system efficiency. Then, the control decisions are based on the pressure drop measured by pressure sensors located along the turbine. A complete wave-to-wire model is developed so as to validate the performance of the proposed control method. For this purpose, a novel sensor-based flow controller is implemented based on the different measured signals. Thus, the performance of the proposed controller has been analyzed and compared with a case of uncontrolled plant. The simulations demonstrate that the flow control-based MPPT strategy is able to increase the output power, and they confirm both the viability and goodness. PMID:29439408

  18. A Power Conditioning Stage Based on Analog-Circuit MPPT Control and a Superbuck Converter for Thermoelectric Generators in Spacecraft Power Systems

    NASA Astrophysics Data System (ADS)

    Sun, Kai; Wu, Hongfei; Cai, Yan; Xing, Yan

    2014-06-01

    A thermoelectric generator (TEG) is a very important kind of power supply for spacecraft, especially for deep-space missions, due to its long lifetime and high reliability. To develop a practical TEG power supply for spacecraft, a power conditioning stage is indispensable, being employed to convert the varying output voltage of the TEG modules to a definite voltage for feeding batteries or loads. To enhance the system reliability, a power conditioning stage based on analog-circuit maximum-power-point tracking (MPPT) control and a superbuck converter is proposed in this paper. The input of this power conditioning stage is connected to the output of the TEG modules, and the output of this stage is connected to the battery and loads. The superbuck converter is employed as the main circuit, featuring low input current ripples and high conversion efficiency. Since for spacecraft power systems reliable operation is the key target for control circuits, a reset-set flip-flop-based analog circuit is used as the basic control circuit to implement MPPT, being much simpler than digital control circuits and offering higher reliability. Experiments have verified the feasibility and effectiveness of the proposed power conditioning stage. The results show the advantages of the proposed stage, such as maximum utilization of TEG power, small input ripples, and good stability.

  19. Tracking the global maximum power point of PV arrays under partial shading conditions

    NASA Astrophysics Data System (ADS)

    Fennich, Meryem

    This thesis presents the theoretical and simulation studies of the global maximum power point tracking (MPPT) for photovoltaic systems under partial shading. The main goal is to track the maximum power point of the photovoltaic module so that the maximum possible power can be extracted from the photovoltaic panels. When several panels are connected in series with some of them shaded partially either due to clouds or shadows from neighboring buildings, several local maxima appear in the power vs. voltage curve. A power increment based MPPT algorithm is effective in identifying the global maximum from the several local maxima. Several existing MPPT algorithms are explored and the state-of-the-art power increment method is simulated and tested for various partial shading conditions. The current-voltage and power-voltage characteristics of the PV model are studied under different partial shading conditions, along with five different cases demonstrating how the MPPT algorithm performs when shading switches from one state to another. Each case is supplemented with simulation results. The method of tracking the Global MPP is based on controlling the DC-DC converter connected to the output of the PV array. A complete system simulation including the PV array, the direct current to direct current (DC-DC) converter and the MPPT is presented and tested using MATLAB software. The simulation results show that the MPPT algorithm works very well with the buck converter, while the boost converter needs further changes and implementation.

  20. Fuzzy observer-based control for maximum power-point tracking of a photovoltaic system

    NASA Astrophysics Data System (ADS)

    Allouche, M.; Dahech, K.; Chaabane, M.; Mehdi, D.

    2018-04-01

    This paper presents a novel fuzzy control design method for maximum power-point tracking (MPPT) via a Takagi and Sugeno (TS) fuzzy model-based approach. A knowledge-dynamic model of the PV system is first developed leading to a TS representation by a simple convex polytopic transformation. Then, based on this exact fuzzy representation, a H∞ observer-based fuzzy controller is proposed to achieve MPPT even when we consider varying climatic conditions. A specified TS reference model is designed to generate the optimum trajectory which must be tracked to ensure maximum power operation. The controller and observer gains are obtained in a one-step procedure by solving a set of linear matrix inequalities (LMIs). The proposed method has been compared with some classical MPPT techniques taking into account convergence speed and tracking accuracy. Finally, various simulation and experimental tests have been carried out to illustrate the effectiveness of the proposed TS fuzzy MPPT strategy.

  1. Design of A Grid Integrated PV System with MPPT Control and Voltage Oriented Controller using MATLAB/PLECES

    NASA Astrophysics Data System (ADS)

    Soreng, Bineeta; Behera, Pradyumna; Pradhan, Raseswari

    2017-08-01

    This paper presents model of a grid-integrated photovoltaic array with Maximum Power Point Tracker (MPPT) and voltage oriented controller. The MPPT of the PV array is usually an essential part of PV system as MPPT helps the operating point of the solar array to align its maximum power point. In this model, the MPPT along with a DC-DC converter lets a PV generator to produce continuous power, despite of the measurement conditions. The neutral-point-clamped converter (NPC) with a boost converter raises the voltage from the panels to the DC-link. An LCL-filter smoothens the current ripple caused by the PWM modulation of the grid-side inverter. In addition to the MPPT, the system has two more two controllers, such as voltage controller and a current controller. The voltage control has a PI controller to regulate the PV voltage to optimal level by controlling the amount of current injected into the boost stage. Here, the grid-side converter transfers the power from the DC-link into the grid and maintains the DC-link voltage. Three-phase PV inverters are used for off-grid or designed to create utility frequency AC. The PV system can be connected in series or parallel to get the desired output power. To justify the working of this model, the grid-integrated PV system has been designed in MATLAB/PLECS. The simulation shows the P-V curve of implemented PV Array consisting 4 X 20 modules, reactive, real power, grid voltage and current.

  2. Modular Cascaded H-Bridge Multilevel PV Inverter with Distributed MPPT for Grid-Connected Applications

    DOE PAGES

    Xiao, Bailu; Hang, Lijun; Mei, Jun; ...

    2014-09-04

    This paper presents a modular cascaded H-bridge multilevel photovoltaic (PV) inverter for single- or three-phase grid-connected applications. The modular cascaded multilevel topology helps to improve the efficiency and flexibility of PV systems. To realize better utilization of PV modules and maximize the solar energy extraction, a distributed maximum power point tracking (MPPT) control scheme is applied to both single-phase and three-phase multilevel inverters, which allows the independent control of each dc-link voltage. For three-phase grid-connected applications, PV mismatches may introduce unbalanced supplied power, leading to unbalanced grid current. To solve this issue, a control scheme with modulation compensation is alsomore » proposed. An experimental three-phase 7-level cascaded H-bridge inverter has been built utilizing 9 H-bridge modules (3 modules per phase). Each H-bridge module is connected to a 185 W solar panel. Simulation and experimental results are presented to verify the feasibility of the proposed approach.« less

  3. Performance optimization of a hybrid micro-grid based on double-loop MPPT and SVC-MERS

    NASA Astrophysics Data System (ADS)

    Wei, Yewen; Hou, Xilun; Zhang, Xiang; Xiong, Shengnan; Peng, Fei

    2018-02-01

    With ever-increasing concerns on environmental pollution and energy shortage, the development of renewable resource has attracted a lot of attention. This paper first reviews both the wind and photovoltaic (PV) generation techniques and approaches of micro-grid voltage control. Then, a novel islanded micro-grid, which consists of wind & PV generation and hybrid-energy storage device, is built for application to remote and isolated areas. For the PV power generation branch, a double- maximum power point tracking (MPPT) technique is developed to trace the sunlight and regulate the tilt angle of PV panels. For wind-power generation branch, squirrel cage induction generator (SCIG) is used as its simple structure, robustness and less cost. In order to stabilize the output voltage of SCIGs, a new Static Var Compensator named magnetic energy recovery switch (SVC-MERS) is applied. Finally, experimental results confirm that both of the proposed methods can improve the efficiency of PV power generation and voltage stability of the micro-grid, respectively.

  4. Comparative Clinical Study of the Wound Healing Effects of a Novel Micropore Particle Technology: Effects on Wounds, Venous Leg Ulcers, and Diabetic Foot Ulcers

    PubMed

    Bilyayeva, Olga O; Neshta, Viacheslav V; Golub, Alexander A; Sams-Dodd, Frank

    2017-08-01

    The purpose of this study was to determine the wound healing effects of Acapsil, a white, odorless powder based on micropore particle technology (MPPT) (Willingsford Ltd, Southampton, UK) by comparing it to Gentaxane (Gentaksan, Borshchagovsky CCP, Kyiv, Ukraine) (polydimethylsiloxane powder with gentamicin antibiotic) and Ioddicerin (Farmak, Kyiv, Ukraine) (iodine with dimethyl sulfoxide [DMSO]). The study included 266 patients with primarily trophic ulcers caused by pancreatic diabetes and venous insufficiency of the lower extremities, carbuncles, phlegmons, infected third- or fourth-degree heat burns, and infiltrations of postoperative wounds. The products were applied once daily to the wound until it was clean (ie, free from necrosis, pus, and fibrinogenous thickenings). The number of days (mean ± standard deviation) to a clean wound was 3.0 ± 0.9 for MPPT (n = 88) compared with 7.0 ± 1.2 and 8.0 ± 1.1 for Gentaxane (n = 90) and iodine/DMSO (n = 88), respectively. Thus, MPPT reduced the time to reach a clean wound by 57% and 62%, respectively. Products were used once daily until a clean wound was reached, which also reflects the number of applications. Days to onset of granulation for MPPT, Gentaxane, and iodine/DMSO were 4.5 ± 0.8, 9.2 ± 1.4, and 10.3 ± 1.5 days, respectively; and days to onset of epithelialization were 7.8 ± 1.1, 14.1 ± 1.9, and 16.4 ± 2.7 days, respectively. Subgroup analysis of patients with diabetic foot and venous leg ulcers found that each of these demonstrated the same pattern of healing as the overall study. The number of hospitalization days was 14.6 ± 5.6 for MPPT, 21.0 ± 10.7 for Gentaxane, and 24.0 ± 7.9 for iodine/DMSO. Compared with Gentaxane, patients receiving MPPT had a 31% reduction in hospitalization duration and a 39% reduction compared with iodine/DMSO. These findings demonstrate that MPPT represents a valuable new approach to wound care.

  5. Magnification of starting torques of dc motors by maximum power point trackers in photovoltaic systems

    NASA Technical Reports Server (NTRS)

    Appelbaum, J.; Singer, S.

    1989-01-01

    A calculation of the starting torque ratio of permanent magnet, series, and shunt-excited dc motors powered by solar cell arrays is presented for two cases, i.e., with and without a maximum-power-point tracker (MPPT). Defining motor torque magnification by the ratio of the motor torque with an MPPT to the motor torque without an MPPT, a magnification of 3 for the permanent magnet motor and a magnification of 7 for both the series and shunt motors are obtained. The study also shows that all motor types are less sensitive to solar insolation variation in systems including MPPTs as compared to systems without MPPTs.

  6. Solar Array Hysteresis and its Interaction with the MPPT System

    NASA Astrophysics Data System (ADS)

    Fernandez, A.; Baur, C.; Gomez-Carpintero, F.

    2014-08-01

    It is well known that solar cells have a capacitance in parallel which value changes with the voltage. Depending on the section arrangement on the Solar Array, the power conversion unit connected to it will see a smaller or larger capacitance value and will have to cope with its adverse effects. In the case of converters with an MPPT, this capacitance gives place to an hysteresis effect that might shift the tracking point, reducing the power extracted from the Solar Array. This paper explores the different sides of this issue, from capacitance modelling to the effects on the MPPT. Additionally, this paper analyses a similar interaction between MPPTs and commercial SAS.

  7. Design of MPPT Controller Monitoring Software Based on QT Framework

    NASA Astrophysics Data System (ADS)

    Meng, X. Z.; Lu, P. G.

    2017-10-01

    The MPPT controller was a hardware device for tracking the maximum power point of solar photovoltaic array. Multiple controllers could be working as networking mode by specific communicating protocol. In this article, based on C++ GUI programming with Qt frame, we designed one sort of desktop application for monitoring and analyzing operational parameter of MPPT controller. The type of communicating protocol for building network was Modbus protocol which using Remote Terminal Unit mode and The desktop application of host computer was connected with all the controllers in the network through RS485 communication or ZigBee wireless communication. Using this application, user could monitor the parameter of controller wherever they were by internet.

  8. Power Management System Design for Solar-Powered UAS

    DTIC Science & Technology

    2015-12-01

    PV cells would have their own MPPT modules, which would enable two major advantages. The first can be considered more important to land-based solar ...The efficiency of the PV array is represented by ηpv. R represents the solar irradiance, and θ represents the angle between the array and the sun...SYSTEM DESIGN FOR SOLAR -POWERED UAS by Robert T. Fauci III December 2015 Thesis Advisor: Alejandro Hernandez Co-Advisor: Kevin Jones

  9. Hardware Implementation of Maximum Power Point Tracking for Thermoelectric Generators

    NASA Astrophysics Data System (ADS)

    Maganga, Othman; Phillip, Navneesh; Burnham, Keith J.; Montecucco, Andrea; Siviter, Jonathan; Knox, Andrew; Simpson, Kevin

    2014-06-01

    This work describes the practical implementation of two maximum power point tracking (MPPT) algorithms, namely those of perturb and observe, and extremum seeking control. The proprietary dSPACE system is used to perform hardware in the loop (HIL) simulation whereby the two control algorithms are implemented using the MATLAB/Simulink (Mathworks, Natick, MA) software environment in order to control a synchronous buck-boost converter connected to two commercial thermoelectric modules. The process of performing HIL simulation using dSPACE is discussed, and a comparison between experimental and simulated results is highlighted. The experimental results demonstrate the validity of the two MPPT algorithms, and in conclusion the benefits and limitations of real-time implementation of MPPT controllers using dSPACE are discussed.

  10. Adaptive smart simulator for characterization and MPPT construction of PV array

    NASA Astrophysics Data System (ADS)

    Ouada, Mehdi; Meridjet, Mohamed Salah; Dib, Djalel

    2016-07-01

    Partial shading conditions are among the most important problems in large photovoltaic array. Many works of literature are interested in modeling, control and optimization of photovoltaic conversion of solar energy under partial shading conditions, The aim of this study is to build a software simulator similar to hard simulator and to produce a shading pattern of the proposed photovoltaic array in order to use the delivered information to obtain an optimal configuration of the PV array and construct MPPT algorithm. Graphical user interfaces (Matlab GUI) are built using a developed script, this tool is easy to use, simple, and has a rapid of responsiveness, the simulator supports large array simulations that can be interfaced with MPPT and power electronic converters.

  11. A Study of a Two Stage Maximum Power Point Tracking Control of a Photovoltaic System under Partially Shaded Insolation Conditions

    NASA Astrophysics Data System (ADS)

    Kobayashi, Kenji; Takano, Ichiro; Sawada, Yoshio

    A photovoltaic array shows relatively low output power density, and has a greatly drooping Current-Voltage (I-V) characteristic. Therefore, Maximum Power Point Tracking (MPPT) control is used to maximize the output power of the array. Many papers have been reported in relation to MPPT. However, the Current-Power (I-P) curve sometimes shows multi-local maximum points mode under non-uniform insolation conditions. The operating point of the PV system tends to converge to a local maximum output point which is not the real maximal output point on the I-P curve. Some papers have been also reported, trying to avoid this difficulty. However most of those control systems become rather complicated. Then, the two stage MPPT control method is proposed in this paper to realize a relatively simple control system which can track the real maximum power point even under non-uniform insolation conditions. The feasibility of this control concept is confirmed for steady insolation as well as for rapidly changing insolation by simulation study using software PSIM and LabVIEW. In addition, simulated experiment confirms fundament al operation of the two stage MPPT control.

  12. Adaptive smart simulator for characterization and MPPT construction of PV array

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ouada, Mehdi, E-mail: mehdi.ouada@univ-annaba.org; Meridjet, Mohamed Salah; Dib, Djalel

    2016-07-25

    Partial shading conditions are among the most important problems in large photovoltaic array. Many works of literature are interested in modeling, control and optimization of photovoltaic conversion of solar energy under partial shading conditions, The aim of this study is to build a software simulator similar to hard simulator and to produce a shading pattern of the proposed photovoltaic array in order to use the delivered information to obtain an optimal configuration of the PV array and construct MPPT algorithm. Graphical user interfaces (Matlab GUI) are built using a developed script, this tool is easy to use, simple, and hasmore » a rapid of responsiveness, the simulator supports large array simulations that can be interfaced with MPPT and power electronic converters.« less

  13. Solar micro-power system for self-powered wireless sensor nodes

    NASA Astrophysics Data System (ADS)

    He, Yongtai; Li, Yangqiu; Liu, Lihui; Wang, Lei

    2008-10-01

    In self-powered wireless sensor nodes, the efficiency for environmental energy harvesting, storage and management determines the lifetime and environmental adaptability of the sensor nodes. However, the method of improving output efficiency for traditional photovoltaic power generation is not suitable for a solar micro-power system due to the special requirements for its application. This paper presents a solar micro-power system designed for a solar self-powered wireless sensor node. The Maximum Power Point Tracking (MPPT) of solar cells and energy storage are realized by the hybrid energy storage structure and "window" control. Meanwhile, the mathematical model of energy harvesting, storing and management is formulated. In the novel system, the output conversion efficiency of solar cells is 12%.

  14. A Maximum Power Point Tracking Control Method of a Photovoltaic Power Generator with Consideration of Dynamic Characteristics of Solar Cells

    NASA Astrophysics Data System (ADS)

    Watanabe, Takashi; Yoshida, Toshiya; Ohniwa, Katsumi

    This paper discusses a new control strategy for photovoltaic power generation systems with consideration of dynamic characteristics of the photovoltaic cells. The controller estimates internal currents of an equivalent circuit for the cells. This estimated, or the virtual current and the actual voltage of the cells are fed to a conventional Maximum-Power-Point-Tracking (MPPT) controller. Consequently, this MPPT controller still tracks the optimum point even though it is so designed that the seeking speed of the operating point is extremely high. This system may suit for applications, which are installed in rapidly changeable insolation and temperature-conditions e.g. automobiles, trains, and airplanes. The proposed method is verified by experiment with a combination of this estimating function and the modified Boehringer's MPPT algorithm.

  15. Chaos Quantum-Behaved Cat Swarm Optimization Algorithm and Its Application in the PV MPPT

    PubMed Central

    2017-01-01

    Cat Swarm Optimization (CSO) algorithm was put forward in 2006. Despite a faster convergence speed compared with Particle Swarm Optimization (PSO) algorithm, the application of CSO is greatly limited by the drawback of “premature convergence,” that is, the possibility of trapping in local optimum when dealing with nonlinear optimization problem with a large number of local extreme values. In order to surmount the shortcomings of CSO, Chaos Quantum-behaved Cat Swarm Optimization (CQCSO) algorithm is proposed in this paper. Firstly, Quantum-behaved Cat Swarm Optimization (QCSO) algorithm improves the accuracy of the CSO algorithm, because it is easy to fall into the local optimum in the later stage. Chaos Quantum-behaved Cat Swarm Optimization (CQCSO) algorithm is proposed by introducing tent map for jumping out of local optimum in this paper. Secondly, CQCSO has been applied in the simulation of five different test functions, showing higher accuracy and less time consumption than CSO and QCSO. Finally, photovoltaic MPPT model and experimental platform are established and global maximum power point tracking control strategy is achieved by CQCSO algorithm, the effectiveness and efficiency of which have been verified by both simulation and experiment. PMID:29181020

  16. Chaos Quantum-Behaved Cat Swarm Optimization Algorithm and Its Application in the PV MPPT.

    PubMed

    Nie, Xiaohua; Wang, Wei; Nie, Haoyao

    2017-01-01

    Cat Swarm Optimization (CSO) algorithm was put forward in 2006. Despite a faster convergence speed compared with Particle Swarm Optimization (PSO) algorithm, the application of CSO is greatly limited by the drawback of "premature convergence," that is, the possibility of trapping in local optimum when dealing with nonlinear optimization problem with a large number of local extreme values. In order to surmount the shortcomings of CSO, Chaos Quantum-behaved Cat Swarm Optimization (CQCSO) algorithm is proposed in this paper. Firstly, Quantum-behaved Cat Swarm Optimization (QCSO) algorithm improves the accuracy of the CSO algorithm, because it is easy to fall into the local optimum in the later stage. Chaos Quantum-behaved Cat Swarm Optimization (CQCSO) algorithm is proposed by introducing tent map for jumping out of local optimum in this paper. Secondly, CQCSO has been applied in the simulation of five different test functions, showing higher accuracy and less time consumption than CSO and QCSO. Finally, photovoltaic MPPT model and experimental platform are established and global maximum power point tracking control strategy is achieved by CQCSO algorithm, the effectiveness and efficiency of which have been verified by both simulation and experiment.

  17. Photovoltaic Cells Mppt Algorithm and Design of Controller Monitoring System

    NASA Astrophysics Data System (ADS)

    Meng, X. Z.; Feng, H. B.

    2017-10-01

    This paper combined the advantages of each maximum power point tracking (MPPT) algorithm, put forward a kind of algorithm with higher speed and higher precision, based on this algorithm designed a maximum power point tracking controller with ARM. The controller, communication technology and PC software formed a control system. Results of the simulation and experiment showed that the process of maximum power tracking was effective, and the system was stable.

  18. Variable frequency iteration MPPT for resonant power converters

    DOEpatents

    Zhang, Qian; Bataresh, Issa; Chen, Lin

    2015-06-30

    A method of maximum power point tracking (MPPT) uses an MPPT algorithm to determine a switching frequency for a resonant power converter, including initializing by setting an initial boundary frequency range that is divided into initial frequency sub-ranges bounded by initial frequencies including an initial center frequency and first and second initial bounding frequencies. A first iteration includes measuring initial powers at the initial frequencies to determine a maximum power initial frequency that is used to set a first reduced frequency search range centered or bounded by the maximum power initial frequency including at least a first additional bounding frequency. A second iteration includes calculating first and second center frequencies by averaging adjacent frequent values in the first reduced frequency search range and measuring second power values at the first and second center frequencies. The switching frequency is determined from measured power values including the second power values.

  19. Noble-TLBO MPPT Technique and its Comparative Analysis with Conventional methods implemented on Solar Photo Voltaic System

    NASA Astrophysics Data System (ADS)

    Patsariya, Ajay; Rai, Shiwani; Kumar, Yogendra, Dr.; Kirar, Mukesh, Dr.

    2017-08-01

    The energy crisis particularly with developing GDPs, has bring up to a new panorama of sustainable power source like solar energy, which has encountered huge development. Progressively high infiltration level of photovoltaic (PV) era emerges in keen matrix. Sunlight based power is irregular and variable, as the sun based source at the ground level is exceedingly subject to overcast cover inconstancy, environmental vaporized levels, and other climate parameters. The inalienable inconstancy of substantial scale sun based era acquaints huge difficulties with keen lattice vitality administration. Exact determining of sun powered power/irradiance is basic to secure financial operation of the shrewd framework. In this paper a noble TLBO-MPPT technique has been proposed to address the vitality of solar energy. A comparative analysis has been presented between conventional PO, IC and the proposed MPPT technique. The research has been done on Matlab Simulink software version 2013.

  20. Optimized MPPT algorithm for boost converters taking into account the environmental variables

    NASA Astrophysics Data System (ADS)

    Petit, Pierre; Sawicki, Jean-Paul; Saint-Eve, Frédéric; Maufay, Fabrice; Aillerie, Michel

    2016-07-01

    This paper presents a study on the specific behavior of the Boost DC-DC converters generally used for powering conversion of PV panels connected to a HVDC (High Voltage Direct Current) Bus. It follows some works pointing out that converter MPPT (Maximum Power Point Tracker) is severely perturbed by output voltage variations due to physical dependency of parameters as the input voltage, the output voltage and the duty cycle of the PWM switching control of the MPPT. As a direct consequence many converters connected together on a same load perturb each other because of the output voltage variations induced by fluctuations on the HVDC bus essentially due to a not insignificant bus impedance. In this paper we show that it is possible to include an internal computed variable in charge to compensate local and external variations to take into account the environment variables.

  1. Photovoltaic pumping system - Comparative study analysis between direct and indirect coupling mode

    NASA Astrophysics Data System (ADS)

    Harrag, Abdelghani; Titraoui, Abdessalem; Bahri, Hamza; Messalti, Sabir

    2017-02-01

    In this paper, P&O algorithm is used in order to improve the performance of photovoltaic water pumping system in both dynamic and static response. The efficiency of the proposed algorithm has been studied successfully using a DC motor-pump powered using controller by thirty six PV modules via DC-DC boost converter derived by a P&O MPPT algorithm. Comparative study results between the direct and indirect modes coupling confirm that the proposed algorithm can effectively improve simultaneously: accuracy, rapidity, ripple and overshoot.

  2. Power Considerations for Micro-Autonomous Systems

    DTIC Science & Technology

    2012-07-30

    PV cell APPROVED FOR PUBLIC RELEASE 15 Micro-Thermo- Photovoltaics POC: Ivan Celanovic low- power MPPT micro channel Silicon MEMs reactor Ill...max power density 150 W/kg (3000 mW, 500 sec) APPROVED FOR PUBLIC RELEASE 29 Micro-Thermo- Photovoltaics low- power MPPT micro channel Silicon MEMs...Secondary used as a Primary *Contour  4g (220Whr/kg, 750W/kg), 15g (400 Whr/kg, 1000W/kg) *Sion Power ??? •Lithium-Sulfur: promising rechargeable

  3. An adaptive scale factor based MPPT algorithm for changing solar irradiation levels in outer space

    NASA Astrophysics Data System (ADS)

    Kwan, Trevor Hocksun; Wu, Xiaofeng

    2017-03-01

    Maximum power point tracking (MPPT) techniques are popularly used for maximizing the output of solar panels by continuously tracking the maximum power point (MPP) of their P-V curves, which depend both on the panel temperature and the input insolation. Various MPPT algorithms have been studied in literature, including perturb and observe (P&O), hill climbing, incremental conductance, fuzzy logic control and neural networks. This paper presents an algorithm which improves the MPP tracking performance by adaptively scaling the DC-DC converter duty cycle. The principle of the proposed algorithm is to detect the oscillation by checking the sign (ie. direction) of the duty cycle perturbation between the current and previous time steps. If there is a difference in the signs then it is clear an oscillation is present and the DC-DC converter duty cycle perturbation is subsequently scaled down by a constant factor. By repeating this process, the steady state oscillations become negligibly small which subsequently allows for a smooth steady state MPP response. To verify the proposed MPPT algorithm, a simulation involving irradiances levels that are typically encountered in outer space is conducted. Simulation and experimental results prove that the proposed algorithm is fast and stable in comparison to not only the conventional fixed step counterparts, but also to previous variable step size algorithms.

  4. Simulation and experiment of a fuzzy logic based MPPT controller for a small wind turbine system

    NASA Astrophysics Data System (ADS)

    Petrila, Diana; Muntean, Nicolae

    2012-09-01

    This paper describes the development of a fuzzy logic based maximum power point tracking (MPPT) strategy for a variable speed wind turbine system (VSWT). For this scope, a fuzzy logic controller (FLC) was described, simulated and tested on a real time "hardware in the loop" wind turbine emulator. Simulation and experimental results show that the controller is able to track the maximum power point for various wind conditions and validate the proposed control strategy.

  5. Model Predictive Control techniques with application to photovoltaic, DC Microgrid, and a multi-sourced hybrid energy system

    NASA Astrophysics Data System (ADS)

    Shadmand, Mohammad Bagher

    Renewable energy sources continue to gain popularity. However, two major limitations exist that prevent widespread adoption: availability and variability of the electricity generated and the cost of the equipment. The focus of this dissertation is Model Predictive Control (MPC) for optimal sized photovoltaic (PV), DC Microgrid, and multi-sourced hybrid energy systems. The main considered applications are: maximum power point tracking (MPPT) by MPC, droop predictive control of DC microgrid, MPC of grid-interaction inverter, MPC of a capacitor-less VAR compensator based on matrix converter (MC). This dissertation firstly investigates a multi-objective optimization technique for a hybrid distribution system. The variability of a high-penetration PV scenario is also studied when incorporated into the microgrid concept. Emerging (PV) technologies have enabled the creation of contoured and conformal PV surfaces; the effect of using non-planar PV modules on variability is also analyzed. The proposed predictive control to achieve maximum power point for isolated and grid-tied PV systems speeds up the control loop since it predicts error before the switching signal is applied to the converter. The low conversion efficiency of PV cells means we want to ensure always operating at maximum possible power point to make the system economical. Thus the proposed MPPT technique can capture more energy compared to the conventional MPPT techniques from same amount of installed solar panel. Because of the MPPT requirement, the output voltage of the converter may vary. Therefore a droop control is needed to feed multiple arrays of photovoltaic systems to a DC bus in microgrid community. Development of a droop control technique by means of predictive control is another application of this dissertation. Reactive power, denoted as Volt Ampere Reactive (VAR), has several undesirable consequences on AC power system network such as reduction in power transfer capability and increase in transmission loss if not controlled appropriately. Inductive loads which operate with lagging power factor consume VARs, thus load compensation techniques by capacitor bank employment locally supply VARs needed by the load. Capacitors are highly unreliable components due to their failure modes and aging inherent. Approximately 60% of power electronic devices failure such as voltage-source inverter based static synchronous compensator (STATCOM) is due to the use of aluminum electrolytic DC capacitors. Therefore, a capacitor-less VAR compensation is desired. This dissertation also investigates a STATCOM capacitor-less reactive power compensation that uses only inductors combined with predictive controlled matrix converter.

  6. Maximum power point tracking algorithm based on sliding mode and fuzzy logic for photovoltaic sources under variable environmental conditions

    NASA Astrophysics Data System (ADS)

    Atik, L.; Petit, P.; Sawicki, J. P.; Ternifi, Z. T.; Bachir, G.; Della, M.; Aillerie, M.

    2017-02-01

    Solar panels have a nonlinear voltage-current characteristic, with a distinct maximum power point (MPP), which depends on the environmental factors, such as temperature and irradiation. In order to continuously harvest maximum power from the solar panels, they have to operate at their MPP despite the inevitable changes in the environment. Various methods for maximum power point tracking (MPPT) were developed and finally implemented in solar power electronic controllers to increase the efficiency in the electricity production originate from renewables. In this paper we compare using Matlab tools Simulink, two different MPP tracking methods, which are, fuzzy logic control (FL) and sliding mode control (SMC), considering their efficiency in solar energy production.

  7. Efficiency optimization of a photovoltaic water pumping system for irrigation in Ouargla, Algeria

    NASA Astrophysics Data System (ADS)

    Louazene, M. L.; Garcia, M. C. Alonso; Korichi, D.

    2017-02-01

    This work is technical study to contribute to the optimization of pumping systems powered by solar energy (clean) and used in the field of agriculture. To achieve our goals, we studied the techniques that must be entered on a photovoltaic system for maximum energy from solar panels. Our scientific contribution in this research is the realization of an efficient photovoltaic pumping system for irrigation needs. To achieve this and extract maximum power from the PV generator, two axes have been optimized: 1. Increase in the uptake of solar radiation by choice an optimum tilt angle of the solar panels, and 2. it is necessary to add an adaptation device, MPPT controller with a DC-DC converter, between the source and the load.

  8. The Evaluation of HOMER as a Marine Corps Expeditionary Energy Predeployment Tool

    DTIC Science & Technology

    2010-09-01

    experiment was used to ensure the HOMER models were accurate. Following the calibration, the concept of expeditionary energy density as it pertains to power ...Brigade–Afghanistan xvi MEP Mobile Electric Power MPP Maximum Power Point MPPT Maximum Power Point Tracker NASA National Aeronautics and...process was used to analyze HOMER’s modeling capability: • Conduct photovoltaic (PV) experiment, • Develop a calibration process to match the HOMER

  9. The Evaluation of HOMER as a Marine Corps Expeditionary Energy Pre-deployment Tool

    DTIC Science & Technology

    2010-11-21

    used to ensure the HOMER models were accurate. Following the calibration, the concept of expeditionary energy density as it pertains to power ...MEP Mobile Electric Power MPP Maximum Power Point MPPT Maximum Power Point Tracker NASA National Aeronautics and Space Administration...process was used to analyze HOMER’s modeling capability: • Conduct photovoltaic (PV) experiment, • Develop a calibration process to match the HOMER

  10. A novel maximum power point tracking system employing phase comparison techniques

    NASA Astrophysics Data System (ADS)

    Avaritsiotis, J. N.; Tsitomeneas, S.; Caroubalos, C.

    A new MPPT design is presented that is based on the comparison of the phase of a perturbing signal with that of the signal which is the result of the perturbation. More specifically, a voltage ripple is induced on the power loop of the P/V system and its phase is compared to the phase of the resulting ripple on the electric power P = I x V, where I and V are the current and voltage respectively of the P/V generator. A prototype MPPT based on the previous principle has been designed, constructed, and its performance has been studied.

  11. Research of PV Power Generation MPPT based on GABP Neural Network

    NASA Astrophysics Data System (ADS)

    Su, Yu; Lin, Xianfu

    2018-05-01

    Photovoltaic power generation has become the main research direction of new energy power generation. But high investment and low efficiency of photovoltaic industry arouse concern in some extent. So maximum power point tracking of photovoltaic power generation has been a popular study point. Due to slow response, oscillation at maximum power point and low precision, the algorithm based on genetic algorithm combined with BP neural network are designed detailedly in this paper. And the modeling and simulation are completed by use of MATLAB/SIMULINK. The results show that the algorithm is effective and the maximum power point can be tracked accurately and quickly.

  12. Maximum power point tracking techniques for wind energy systems using three levels boost converter

    NASA Astrophysics Data System (ADS)

    Tran, Cuong Hung; Nollet, Frédéric; Essounbouli, Najib; Hamzaoui, Abdelaziz

    2018-05-01

    This paper presents modeling and simulation of three level Boost DC-DC converter in Wind Energy Conversion System (WECS). Three-level Boost converter has significant advantage compared to conventional Boost. A maximum power point tracking (MPPT) method for a variable speed wind turbine using permanent magnet synchronous generator (PMSG) is also presented. Simulation of three-level Boost converter topology with Perturb and Observe algorithm and Fuzzy Logic Control is implemented in MATLAB/SIMULINK. Results of this simulation show that the system with MPPT using fuzzy logic controller has better performance to the Perturb and Observe algorithm: fast response under changing conditions and small oscillation.

  13. Dynamic Model and Control of a Photovoltaic Generation System using Energetic Macroscopic Representation

    NASA Astrophysics Data System (ADS)

    Solano, Javier; Duarte, José; Vargas, Erwin; Cabrera, Jhon; Jácome, Andrés; Botero, Mónica; Rey, Juan

    2016-10-01

    This paper addresses the Energetic Macroscopic Representation EMR, the modelling and the control of photovoltaic panel PVP generation systems for simulation purposes. The model of the PVP considers the variations on irradiance and temperature. A maximum power point tracking MPPT algorithm is considered to control the power converter. A novel EMR is proposed to consider the dynamic model of the PVP with variations in the irradiance and the temperature. The EMR is evaluated through simulations of a PVP generation system.

  14. Functional organization and restoration of the brain motor-execution network after stroke and rehabilitation

    PubMed Central

    Bajaj, Sahil; Butler, Andrew J.; Drake, Daniel; Dhamala, Mukesh

    2015-01-01

    Multiple cortical areas of the human brain motor system interact coherently in the low frequency range (<0.1 Hz), even in the absence of explicit tasks. Following stroke, cortical interactions are functionally disturbed. How these interactions are affected and how the functional organization is regained from rehabilitative treatments as people begin to recover motor behaviors has not been systematically studied. We recorded the intrinsic functional magnetic resonance imaging (fMRI) signals from 30 participants: 17 young healthy controls and 13 aged stroke survivors. Stroke participants underwent mental practice (MP) or both mental practice and physical therapy (MP+PT) within 14–51 days following stroke. We investigated the network activity of five core areas in the motor-execution network, consisting of the left primary motor area (LM1), the right primary motor area (RM1), the left pre-motor cortex (LPMC), the right pre-motor cortex (RPMC) and the supplementary motor area (SMA). We discovered that (i) the network activity dominated in the frequency range 0.06–0.08 Hz for all the regions, and for both able-bodied and stroke participants (ii) the causal information flow between the regions: LM1 and SMA, RPMC and SMA, RPMC and LM1, SMA and RM1, SMA and LPMC, was reduced significantly for stroke survivors (iii) the flow did not increase significantly after MP alone and (iv) the flow among the regions during MP+PT increased significantly. We also found that sensation and motor scores were significantly higher and correlated with directed functional connectivity measures when the stroke-survivors underwent MP+PT but not MP alone. The findings provide evidence that a combination of mental practice and physical therapy can be an effective means of treatment for stroke survivors to recover or regain the strength of motor behaviors, and that the spectra of causal information flow can be used as a reliable biomarker for evaluating rehabilitation in stroke survivors. PMID:25870557

  15. Practical Efficiency of Photovoltaic Panel Used for Solar Vehicles

    NASA Astrophysics Data System (ADS)

    Koyuncu, T.

    2017-08-01

    In this experimental investigation, practical efficiency of semi-flexible monocrystalline silicon solar panel used for a solar powered car called “Firat Force” and a solar powered minibus called “Commagene” was determined. Firat Force has 6 solar PV modules, a maintenance free long life gel battery pack, a regenerative brushless DC electric motor and Commagene has 12 solar PV modules, a maintenance free long life gel battery pack, a regenerative brushless DC electric motor. In addition, both solar vehicles have MPPT (Maximum power point tracker), ECU (Electronic control unit), differential, instrument panel, steering system, brake system, brake and gas pedals, mechanical equipments, chassis and frame. These two solar vehicles were used for people transportation in Adiyaman city, Turkey, during one year (June 2010-May 2011) of test. As a result, the practical efficiency of semi-flexible monocrystalline silicon solar panel used for Firat Force and Commagene was determined as 13 % in despite of efficiency value of 18% (at 1000 W/m2 and 25 °C ) given by the producer company. Besides, the total efficiency (from PV panels to vehicle wheel) of the system was also defined as 9%.

  16. Comparative Study Between Wind and Photovoltaic (PV) Systems

    NASA Astrophysics Data System (ADS)

    Taha, Wesam

    This paper reviews two renewable energy systems; wind and photovoltaic (PV) systems. The common debate between the two of them is to conclude which one is better, in terms of cost and efficiency. Therefore, comparative study, in terms of cost and efficiency, is attempted. Regarding total cost of both, wind and PV systems, many parameters must be taken into consideration such as availability of energy (either wind or solar), operation and maintenance, availability of costumers, political influence, and the components used in building the system. The main components and parameters that play major role in determining the overall efficiency of wind systems are the wind turbine generator (WTG), gearbox and control technologies such as power, and speed control. On the other hand, in grid-connected PV systems (GCPVS), converter architecture along with maximum power point tracking (MPPT) algorithm and inverter topologies are the issues that affects the efficiency significantly. Cost and efficiency analyses of both systems have been carried out based on the statistics available till today and would be useful in the progress of renewable energy penetration throughout the world.

  17. Chapter 11.2: Inverters, Power Optimizers, and Microinverters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deline, Christopher A

    Inverters span a wide range of sizes, topologies, and connection voltages: from utility-scale megawatt inverters to string inverters. Switch-mode power conversion relies on high frequency chopping of DC signal to periodically charge and discharge energy storage elements, such as inductors and capacitors. Additional circuit components are required to address practical issues in inverters such as voltage ripple and harmonic distortion. Inverters are beginning to incorporate components with a bandgap above should be 3 eV, such as SiC and GaN. Photovoltaic (PV) modules respond dynamically to changing temperature and irradiation conditions. Thus, maximum DC power extraction requires periodic adjustment of themore » PV voltage and current operating point. An inverter's total efficiency is measured by the product of its conversion efficiency and the maximum-power-point tracking (MPPT) efficiency. This chapter lists the primary functions of inverters that include auxiliary capabilities, such as monitoring of DC and AC performance, and other error reporting.« less

  18. Maximum power point tracker for photovoltaic power plants

    NASA Astrophysics Data System (ADS)

    Arcidiacono, V.; Corsi, S.; Lambri, L.

    The paper describes two different closed-loop control criteria for the maximum power point tracking of the voltage-current characteristic of a photovoltaic generator. The two criteria are discussed and compared, inter alia, with regard to the setting-up problems that they pose. Although a detailed analysis is not embarked upon, the paper also provides some quantitative information on the energy advantages obtained by using electronic maximum power point tracking systems, as compared with the situation in which the point of operation of the photovoltaic generator is not controlled at all. Lastly, the paper presents two high-efficiency MPPT converters for experimental photovoltaic plants of the stand-alone and the grid-interconnected type.

  19. Comparative study of adaptive controller using MIT rules and Lyapunov method for MPPT standalone PV systems

    NASA Astrophysics Data System (ADS)

    Tariba, N.; Bouknadel, A.; Haddou, A.; Ikken, N.; Omari, Hafsa El; Omari, Hamid El

    2017-01-01

    The Photovoltaic Generator have a nonlinear characteristic function relating the intensity at the voltage I = f (U) and depend on the variation of solar irradiation and temperature, In addition, its point of operation depends directly on the load that it supplies. To fix this drawback, and to extract the maximum power available to the terminal of the generator, an adaptation stage is introduced between the generator and the load to couple the two elements as perfectly as possible. The adaptation stage is associated with a command called MPPT MPPT (Maximum Power Point Tracker) whose is used to force the PVG to operate at the MPP (Maximum Power Point) under variation of climatic conditions and load variation. This paper presents a comparative study between the adaptive controller for PV Systems using MIT rules and Lyapunov method to regulate the PV voltage. The Incremental Conductance (IC) algorithm is used to extract the maximum power from the PVG by calculating the voltage Vref, and the adaptive controller is used to regulate and track quickly the PV voltage. The two methods of the adaptive controller will be compared to prove their performance by using the PSIM tools and experimental test, and the mathematical model of step-up with PVG model will be presented.

  20. Intelligent energy harvesting scheme for microbial fuel cells: Maximum power point tracking and voltage overshoot avoidance

    NASA Astrophysics Data System (ADS)

    Alaraj, Muhannad; Radenkovic, Miloje; Park, Jae-Do

    2017-02-01

    Microbial fuel cells (MFCs) are renewable and sustainable energy sources that can be used for various applications. The MFC output power depends on its biochemical conditions as well as the terminal operating points in terms of output voltage and current. There exists one operating point that gives the maximum possible power from the MFC, maximum power point (MPP), for a given operating condition. However, this MPP may vary and needs to be tracked in order to maintain the maximum power extraction from the MFC. Furthermore, MFC reactors often develop voltage overshoots that cause drastic drops in the terminal voltage, current, and the output power. When the voltage overshoot happens, an additional control measure is necessary as conventional MPPT algorithms will fail because of the change in the voltage-current relationship. In this paper, the extremum seeking (ES) algorithm was used to track the varying MPP and a voltage overshoot avoidance (VOA) algorithm is developed to manage the voltage overshoot conditions. The proposed ES-MPPT with VOA algorithm was able to extract 197.2 mJ during 10-min operation avoiding voltage overshoot, while the ES MPPT-only scheme stopped harvesting after only 18.75 mJ because of the voltage overshoot happened at 0.4 min.

  1. Prototype Combined Heater/Thermoelectric Power Generator for Remote Applications

    NASA Astrophysics Data System (ADS)

    Champier, D.; Favarel, C.; Bédécarrats, J. P.; Kousksou, T.; Rozis, J. F.

    2013-07-01

    This study presents a prototype thermoelectric generator (TEG) developed for remote applications in villages that are not connected to the electrical power grid. For ecological and economic reasons, there is growing interest in harvesting waste heat from biomass stoves to produce some electricity. Because regular maintenance is not required, TEGs are an attractive choice for small-scale power generation in inaccessible areas. The prototype developed in our laboratory is especially designed to be implemented in stoves that are also used for domestic hot water heating. The aim of this system is to provide a few watts to householders, so they have the ability to charge cellular phones and radios, and to get some light at night. A complete prototype TEG using commercial (bismuth telluride) thermoelectric modules has been built, including system integration with an electric DC/DC converter. The DC/DC converter has a maximum power point tracker (MPPT) driven by an MC9SO8 microcontroller, which optimizes the electrical energy stored in a valve-regulated lead-acid battery. Physical models were used to study the behavior of the thermoelectric system and to optimize the performance of the MPPT. Experiments using a hot gas generator to simulate the exhaust of the combustion chamber of a stove are used to evaluate the system. Additionally, potential uses of such generators are presented.

  2. Power Control and Optimization of Photovoltaic and Wind Energy Conversion Systems

    NASA Astrophysics Data System (ADS)

    Ghaffari, Azad

    Power map and Maximum Power Point (MPP) of Photovoltaic (PV) and Wind Energy Conversion Systems (WECS) highly depend on system dynamics and environmental parameters, e.g., solar irradiance, temperature, and wind speed. Power optimization algorithms for PV systems and WECS are collectively known as Maximum Power Point Tracking (MPPT) algorithm. Gradient-based Extremum Seeking (ES), as a non-model-based MPPT algorithm, governs the system to its peak point on the steepest descent curve regardless of changes of the system dynamics and variations of the environmental parameters. Since the power map shape defines the gradient vector, then a close estimate of the power map shape is needed to create user assignable transients in the MPPT algorithm. The Hessian gives a precise estimate of the power map in a neighborhood around the MPP. The estimate of the inverse of the Hessian in combination with the estimate of the gradient vector are the key parts to implement the Newton-based ES algorithm. Hence, we generate an estimate of the Hessian using our proposed perturbation matrix. Also, we introduce a dynamic estimator to calculate the inverse of the Hessian which is an essential part of our algorithm. We present various simulations and experiments on the micro-converter PV systems to verify the validity of our proposed algorithm. The ES scheme can also be used in combination with other control algorithms to achieve desired closed-loop performance. The WECS dynamics is slow which causes even slower response time for the MPPT based on the ES. Hence, we present a control scheme, extended from Field-Oriented Control (FOC), in combination with feedback linearization to reduce the convergence time of the closed-loop system. Furthermore, the nonlinear control prevents magnetic saturation of the stator of the Induction Generator (IG). The proposed control algorithm in combination with the ES guarantees the closed-loop system robustness with respect to high level parameter uncertainty in the IG dynamics. The simulation results verify the effectiveness of the proposed algorithm.

  3. Maximum Power Point Tracking with Dichotomy and Gradient Method for Automobile Exhaust Thermoelectric Generators

    NASA Astrophysics Data System (ADS)

    Fang, W.; Quan, S. H.; Xie, C. J.; Tang, X. F.; Wang, L. L.; Huang, L.

    2016-03-01

    In this study, a direct-current/direct-current (DC/DC) converter with maximum power point tracking (MPPT) is developed to down-convert the high voltage DC output from a thermoelectric generator to the lower voltage required to charge batteries. To improve the tracking accuracy and speed of the converter, a novel MPPT control scheme characterized by an aggregated dichotomy and gradient (ADG) method is proposed. In the first stage, the dichotomy algorithm is used as a fast search method to find the approximate region of the maximum power point. The gradient method is then applied for rapid and accurate tracking of the maximum power point. To validate the proposed MPPT method, a test bench composed of an automobile exhaust thermoelectric generator was constructed for harvesting the automotive exhaust heat energy. Steady-state and transient tracking experiments under five different load conditions were carried out using a DC/DC converter with the proposed ADG and with three traditional methods. The experimental results show that the ADG method can track the maximum power within 140 ms with a 1.1% error rate when the engine operates at 3300 rpm@71 NM, which is superior to the performance of the single dichotomy method, the single gradient method and the perturbation and observation method from the viewpoint of improved tracking accuracy and speed.

  4. Modeling and analysis of solar distributed generation

    NASA Astrophysics Data System (ADS)

    Ortiz Rivera, Eduardo Ivan

    Recent changes in the global economy are creating a big impact in our daily life. The price of oil is increasing and the number of reserves are less every day. Also, dramatic demographic changes are impacting the viability of the electric infrastructure and ultimately the economic future of the industry. These are some of the reasons that many countries are looking for alternative energy to produce electric energy. The most common form of green energy in our daily life is solar energy. To convert solar energy into electrical energy is required solar panels, dc-dc converters, power control, sensors, and inverters. In this work, a photovoltaic module, PVM, model using the electrical characteristics provided by the manufacturer data sheet is presented for power system applications. Experimental results from testing are showed, verifying the proposed PVM model. Also in this work, three maximum power point tracker, MPPT, algorithms would be presented to obtain the maximum power from a PVM. The first MPPT algorithm is a method based on the Rolle's and Lagrange's Theorems and can provide at least an approximate answer to a family of transcendental functions that cannot be solved using differential calculus. The second MPPT algorithm is based on the approximation of the proposed PVM model using fractional polynomials where the shape, boundary conditions and performance of the proposed PVM model are satisfied. The third MPPT algorithm is based in the determination of the optimal duty cycle for a dc-dc converter and the previous knowledge of the load or load matching conditions. Also, four algorithms to calculate the effective irradiance level and temperature over a photovoltaic module are presented in this work. The main reasons to develop these algorithms are for monitoring climate conditions, the elimination of temperature and solar irradiance sensors, reductions in cost for a photovoltaic inverter system, and development of new algorithms to be integrated with maximum power point tracking algorithms. Finally, several PV power applications will be presented like circuit analysis for a load connected to two different PV arrays, speed control for a do motor connected to a PVM, and a novel single phase photovoltaic inverter system using the Z-source converter.

  5. A novel power converter for photovoltaic applications

    NASA Astrophysics Data System (ADS)

    Yuvarajan, S.; Yu, Dachuan; Xu, Shanguang

    A simple and economical power conditioner to convert the power available from solar panels into 60 Hz ac voltage is described. The raw dc voltage from the solar panels is converted to a regulated dc voltage using a boost converter and a large capacitor and the dc output is then converted to 60 Hz ac using a bridge inverter. The ratio between the load current and the short-circuit current of a PV panel at maximum power point is nearly constant for different insolation (light) levels and this property is utilized in designing a simple maximum power point tracking (MPPT) controller. The controller includes a novel arrangement for sensing the short-circuit current without disturbing the operation of the PV panel and implementing MPPT. The switching losses in the inverter are reduced by using snubbers. The results obtained on an experimental converter are presented.

  6. Starting characteristics of direct current motors powered by solar cells

    NASA Technical Reports Server (NTRS)

    Singer, S.; Appelbaum, J.

    1989-01-01

    Direct current motors are used in photovoltaic systems. Important characteristics of electric motors are the starting to rated current and torque ratios. These ratios are dictated by the size of the solar cell array and are different for the various dc motor types. Discussed here is the calculation of the starting to rated current ratio and starting to rated torque ratio of the permanent magnet, and series and shunt excited motors when powered by solar cells for two cases: with and without a maximum-power-point-tracker (MPPT) included in the system. Comparing these two cases, one gets a torque magnification of about 3 for the permanent magnet motor and about 7 for other motor types. The calculation of the torques may assist the PV system designer to determine whether or not to include an MPPT in the system.

  7. Computerized implementation of higher-order electron-correlation methods and their linear-scaling divide-and-conquer extensions.

    PubMed

    Nakano, Masahiko; Yoshikawa, Takeshi; Hirata, So; Seino, Junji; Nakai, Hiromi

    2017-11-05

    We have implemented a linear-scaling divide-and-conquer (DC)-based higher-order coupled-cluster (CC) and Møller-Plesset perturbation theories (MPPT) as well as their combinations automatically by means of the tensor contraction engine, which is a computerized symbolic algebra system. The DC-based energy expressions of the standard CC and MPPT methods and the CC methods augmented with a perturbation correction were proposed for up to high excitation orders [e.g., CCSDTQ, MP4, and CCSD(2) TQ ]. The numerical assessment for hydrogen halide chains, polyene chains, and first coordination sphere (C1) model of photoactive yellow protein has revealed that the DC-based correlation methods provide reliable correlation energies with significantly less computational cost than that of the conventional implementations. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  8. Fuzzy logic, PSO based fuzzy logic algorithm and current controls comparative for grid-connected hybrid system

    NASA Astrophysics Data System (ADS)

    Borni, A.; Abdelkrim, T.; Zaghba, L.; Bouchakour, A.; Lakhdari, A.; Zarour, L.

    2017-02-01

    In this paper the model of a grid connected hybrid system is presented. The hybrid system includes a variable speed wind turbine controlled by aFuzzy MPPT control, and a photovoltaic generator controlled with PSO Fuzzy MPPT control to compensate the power fluctuations caused by the wind in a short and long term, the inverter currents injected to the grid is controlled by a decoupled PI current control. In the first phase, we start by modeling of the conversion system components; the wind system is consisted of a turbine coupled to a gearless permanent magnet generator (PMG), the AC/DC and DC-DC (Boost) converter are responsible to feed the electric energy produced by the PMG to the DC-link. The solar system consists of a photovoltaic generator (GPV) connected to a DC/DC boost converter controlled by a PSO fuzzy MPPT control to extract at any moment the maximum available power at the GPV terminals, the system is based on maximum utilization of both of sources because of their complementary. At the end. The active power reached to the DC-link is injected to the grid through a DC/AC inverter, this function is achieved by controlling the DC bus voltage to keep it constant and close to its reference value, The simulation studies have been performed using Matlab/Simulink. It can be concluded that a good control system performance can be achieved.

  9. A 66pW Discontinuous Switch-Capacitor Energy Harvester for Self-Sustaining Sensor Applications

    PubMed Central

    Wu, Xiao; Shi, Yao; Jeloka, Supreet; Yang, Kaiyuan; Lee, Inhee; Sylvester, Dennis; Blaauw, David

    2016-01-01

    We present a discontinuous harvesting approach for switch capacitor DC-DC converters that enables ultra-low power energy harvesting. By slowly accumulating charge on an input capacitor and then transferring it to a battery in burst-mode, switching and leakage losses in the DC-DC converter can be optimally traded-off with the loss due to non-ideal MPPT operation. The harvester uses a 15pW mode controller, an automatic conversion ratio modulator, and a moving sum charge pump for low startup energy upon a mode switch. In 180nm CMOS, the harvester achieves >40% end-to-end efficiency from 113pW to 1.5μW with 66pW minimum input power, marking a >10× improvement over prior ultra-low power harvesters. PMID:28392977

  10. A 66pW Discontinuous Switch-Capacitor Energy Harvester for Self-Sustaining Sensor Applications.

    PubMed

    Wu, Xiao; Shi, Yao; Jeloka, Supreet; Yang, Kaiyuan; Lee, Inhee; Sylvester, Dennis; Blaauw, David

    2016-06-01

    We present a discontinuous harvesting approach for switch capacitor DC-DC converters that enables ultra-low power energy harvesting. By slowly accumulating charge on an input capacitor and then transferring it to a battery in burst-mode, switching and leakage losses in the DC-DC converter can be optimally traded-off with the loss due to non-ideal MPPT operation. The harvester uses a 15pW mode controller, an automatic conversion ratio modulator, and a moving sum charge pump for low startup energy upon a mode switch. In 180nm CMOS, the harvester achieves >40% end-to-end efficiency from 113pW to 1.5μW with 66pW minimum input power, marking a >10× improvement over prior ultra-low power harvesters.

  11. Optimal Design of MPPT Controllers for Grid Connected Photovoltaic Array System

    NASA Astrophysics Data System (ADS)

    Ebrahim, M. A.; AbdelHadi, H. A.; Mahmoud, H. M.; Saied, E. M.; Salama, M. M.

    2016-10-01

    Integrating photovoltaic (PV) plants into electric power system exhibits challenges to power system dynamic performance. These challenges stem primarily from the natural characteristics of PV plants, which differ in some respects from the conventional plants. The most significant challenge is how to extract and regulate the maximum power from the sun. This paper presents the optimal design for the most commonly used Maximum Power Point Tracking (MPPT) techniques based on Proportional Integral tuned by Particle Swarm Optimization (PI-PSO). These suggested techniques are, (1) the incremental conductance, (2) perturb and observe, (3) fractional short circuit current and (4) fractional open circuit voltage techniques. This research work provides a comprehensive comparative study with the energy availability ratio from photovoltaic panels. The simulation results proved that the proposed controllers have an impressive tracking response. The system dynamic performance improved greatly using the proposed controllers.

  12. 76 FR 57796 - Petition for Waiver of Compliance

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-16

    ... CP Solomon at MP-PT 352.5 near Pittsburgh, PA, with an absolute block to be established in advance of... Solomon. 3. Operations on the Fort Wayne Line, Pittsburgh Division, from CP Rochester at MP-PC 29.5, near...

  13. Power Smoothing and MPPT for Grid-connected Wind Power Generation with Doubly Fed Induction Generator

    NASA Astrophysics Data System (ADS)

    Kai, Takaaki; Tanaka, Yuji; Kaneda, Hirotoshi; Kobayashi, Daichi; Tanaka, Akio

    Recently, doubly fed induction generator (DFIG) and synchronous generator are mostly applied for wind power generation, and variable speed control and power factor control are executed for high efficiently for wind energy capture and high quality for power system voltage. In variable speed control, a wind speed or a generator speed is used for maximum power point tracking. However, performances of a wind generation power fluctuation due to wind speed variation have not yet investigated for those controls. The authors discuss power smoothing by those controls for the DFIG inter-connected to 6.6kV distribution line. The performances are verified using power system simulation software PSCAD/EMTDC for actual wind speed data and are examined from an approximate equation of wind generation power fluctuation for wind speed variation.

  14. Modeling and Simulation for an 8 kW Three-Phase Grid-Connected Photo-Voltaic Power System

    NASA Astrophysics Data System (ADS)

    Cen, Zhaohui

    2017-09-01

    Gird-connected Photo-Voltaic (PV) systems rated as 5-10 kW level have advantages of scalability and energy-saving, so they are very typical for small-scale household solar applications. In this paper, an 8 kW three-phase grid-connected PV system model is proposed and studied. In this high-fidelity model, some basic PV system components such as solar panels, DC-DC converters, DC-AC inverters and three-phase utility grids are mathematically modelled and organized as a complete simulation model. Also, an overall power controller with Maximum Power Point Control (MPPT) is proposed to achieve both high-efficiency for solar energy harvesting and grid-connection stability. Finally, simulation results demonstrate the effectiveness of the PV system model and the proposed controller, and power quality issues are discussed.

  15. A technological review on electric vehicle DC charging stations using photovoltaic sources

    NASA Astrophysics Data System (ADS)

    Youssef, Cheddadi; Fatima, Errahimi; najia, Es-sbai; Chakib, Alaoui

    2018-05-01

    Within the next few years, Electrified vehicles are destined to become the essential component of the transport field. Consequently, the charging infrastructure should be developed in the same time. Among this substructure, Charging stations photovoltaic-assisted are attracting a substantial interest due to increased environmental awareness, cost reduction and rise in efficiency of the PV modules. The intention of this paper is to review the technological status of Photovoltaic–Electric vehicle (PV-EV) charging stations during the last decade. The PV-EV charging station is divided into two categories, which are PV-grid and PV-standalone charging systems. From a practical point view, the distinction between the two architectures is the bidirectional inverter, which is added to link the station to the smart grid. The technological infrastructure includes the common hardware components of every station, namely: PV array, dc-dc converter provided with MPPT control, energy storage unit, bidirectional dc charger and inverter. We investigate, compare and evaluate many valuable researches that contain the design and control of PV-EV charging system. Additionally, this concise overview reports the studies that include charging standards, the power converters topologies that focus on the adoption of Vehicle-to grid technology and the control for both PV–grid and PV standalone DC charging systems.

  16. MPPT implementation for the outdoor characterization of CPV modules

    NASA Astrophysics Data System (ADS)

    Sánchez, Daniel; Mora, Jaime; Calvo-Parra, Gustavo; Martínez, María

    2015-09-01

    One of the challenges during the characterization of CPV modules is to deal with the thermal behavior. During normal operation in the field the concentrator is connected to the inverter and a fraction of the energy coming from the sun is dissipated with the corresponding conversion into electricity. On the other hand, when making the characterization of CPV modules, they are usually kept in VOC between I-V sweeps, what means that none energy is converted into electricity resulting in a higher operation temperature. Current standards, like IEC-62108:2007 and IEC-62670-3 C01 draft, define that, during the outdoor characterization, the CPV module should be connected to an electrical load to maintain it near MPP between I-V sweeps, what simulates normal operating conditions. The easiest solution could be to use mini-inverters, but it is an expensive solution and not easily adaptable to the different technologies. ISFOC has designed and developed a low-cost MPPT equipment that can be easily implemented in an outdoor characterization laboratory. This equipment is compatible with most of the CPV technologies since it covers a wide range of voltage and current values (up to 150V and 10A) and it is able to distinguish between absolute and local MPP what permits working with modules in any phase of development or making shading effects measurements. Currently, the MPPT is implemented and in operation at ISFOC's outdoor laboratory to make the long term validation. But the results obtained up to now are very promising; the equipment is able to maintain the CPV module under test within a ±3% of the expected power in stable conditions and is able to keep tracking the MPP after any variation in the operating conditions, like cloudy periods, tracking incidence, shading, etc.

  17. Voltage oriented control of self-excited induction generator for wind energy system with MPPT

    NASA Astrophysics Data System (ADS)

    Amieur, Toufik; Taibi, Djamel; Amieur, Oualid

    2018-05-01

    This paper presents the study and simulation of the self-excited induction generator in the wind power production in isolated sites. With this intention, a model of the wind turbine was established. Extremum-seeking control algorithm method by using Maximum Power Point Tracking (MPPT) is proposed control solution aims at driving the average position of the operating point near to optimality. The reference of turbine rotor speed is adjusted such that the turbine operates around maximum power for the current wind speed value. After a brief review of the concepts of converting wind energy into electrical energy. The proposed modeling tools were developed to study the performance of standalone induction generators connected to capacitor bank. The purpose of this technique is to maintain a constant voltage at the output of the rectifier whatever the loads and speeds. The system studied in this work is developed and tested in MATLAB/Simulink environment. Simulation results validate the performance and effectiveness of the proposed control methods.

  18. Different types of maximum power point tracking techniques for renewable energy systems: A survey

    NASA Astrophysics Data System (ADS)

    Khan, Mohammad Junaid; Shukla, Praveen; Mustafa, Rashid; Chatterji, S.; Mathew, Lini

    2016-03-01

    Global demand for electricity is increasing while production of energy from fossil fuels is declining and therefore the obvious choice of the clean energy source that is abundant and could provide security for development future is energy from the sun. In this paper, the characteristic of the supply voltage of the photovoltaic generator is nonlinear and exhibits multiple peaks, including many local peaks and a global peak in non-uniform irradiance. To keep global peak, MPPT is the important component of photovoltaic systems. Although many review articles discussed conventional techniques such as P & O, incremental conductance, the correlation ripple control and very few attempts have been made with intelligent MPPT techniques. This document also discusses different algorithms based on fuzzy logic, Ant Colony Optimization, Genetic Algorithm, artificial neural networks, Particle Swarm Optimization Algorithm Firefly, Extremum seeking control method and hybrid methods applied to the monitoring of maximum value of power at point in systems of photovoltaic under changing conditions of irradiance.

  19. Flexible wearable sensor nodes with solar energy harvesting.

    PubMed

    Taiyang Wu; Arefin, Md Shamsul; Redoute, Jean-Michel; Yuce, Mehmet Rasit

    2017-07-01

    Wearable sensor nodes have gained a lot of attention during the past few years as they can monitor and record people's physical parameters in real time. Wearable sensor nodes can promote healthy lifestyles and prevent the occurrence of potential illness or injuries. This paper presents a flexible wearable sensor system powered by an efficient solar energy harvesting technique. It can measure the subject's heartbeats using a photoplethysmography (PPG) sensor and perform activity monitoring using an accelerometer. The solar energy harvester adopts an output current based maximum power point tracking (MPPT) algorithm, which controls the solar panel to operate within its high output power range. The power consumption of the flexible sensor nodes has been investigated under different operation conditions. Experimental results demonstrate that wearable sensor nodes can work for more than 12 hours when they are powered by the solar energy harvester for 3 hours in the bright sunlight.

  20. A hybrid indoor ambient light and vibration energy harvester for wireless sensor nodes.

    PubMed

    Yu, Hua; Yue, Qiuqin; Zhou, Jielin; Wang, Wei

    2014-05-19

    To take advantage of applications where both light and vibration energy are available, a hybrid indoor ambient light and vibration energy harvesting scheme is proposed in this paper. This scheme uses only one power conditioning circuit to condition the combined output power harvested from both energy sources so as to reduce the power dissipation. In order to more accurately predict the instantaneous power harvested from the solar panel, an improved five-parameter model for small-scale solar panel applying in low light illumination is presented. The output voltage is increased by using the MEMS piezoelectric cantilever arrays architecture. It overcomes the disadvantage of traditional MEMS vibration energy harvester with low voltage output. The implementation of the maximum power point tracking (MPPT) for indoor ambient light is implemented using analog discrete components, which improves the whole harvester efficiency significantly compared to the digital signal processor. The output power of the vibration energy harvester is improved by using the impedance matching technique. An efficient mechanism of energy accumulation and bleed-off is also discussed. Experiment results obtained from an amorphous-silicon (a-Si) solar panel of 4.8 × 2.0 cm2 and a fabricated piezoelectric MEMS generator of 11 × 12.4 mm2 show that the hybrid energy harvester achieves a maximum efficiency around 76.7%.

  1. Solar Array Power Conditioning for a Spinning Satellite

    NASA Astrophysics Data System (ADS)

    De Luca, Antonio; Chirulli, Giovanni

    2008-09-01

    The conditioning of the output power from a solar array can mainly be achieved by the adoption of DET or MPPT based architecture. There are several factors that can orientate the choice of the system designer towards one solution or the other; some of them maybe inherent to the mission derived requirements (Illumination levels, EMC cleanliness, etc.), others come directly from a careful assessment of performances and losses of both power conditioner and solar array.Definition of the criteria on which basis the final choice is justified is important as they have to guarantee a clear determination of the available versus the required power in all those mission conditions identifiable as design drivers for the overall satellite system both in terms of mass and costs.Such criteria cannot just be simple theoretical enunciations of principles; nor the meticulous definition of them on a case by case basis for different types of missions as neither option gives a guarantee of being conclusive.The aim of this paper is then to suggest assessment steps and guidelines that can be considered generically valid for any mission case, starting from the exposition of the trade off activity performed in order to choose the power conditioning solution for a spinning satellite having unregulated power bus architecture. Calculations and numerical simulations have been made in order to establish the needed solar array surface in case of adoption of a DET or MPPT solution, taking into account temperature and illumination levels on the solar cells, as well as power losses and inefficiencies from the solar generator to the main power bus, in different mission phases. Particular attention has been taken in order to correctly evaluate the thermal effects on the rest of the spacecraft as function of the adopted power system regulation.

  2. The effect of seasonal variation on the performances of grid connected photovoltaic system in southern of Algeria

    NASA Astrophysics Data System (ADS)

    Zaghba, L.; Khennane, M.; Terki, N.; Borni, A.; Bouchakour, A.; Fezzani, A.; Mahamed, I. Hadj; Oudjana, S. H.

    2017-02-01

    This paper presents modeling, simulation, and analysis evaluation of the grid-connected PV generation system performance under MATLAB/Simulink. The objective is to study the effect of seasonal variation on the performances of grid connected photovoltaic system in southern of Algeria. This system works with a power converter. This converter allows the connection to the network and extracts maximum power from photovoltaic panels with the MPPT algorithm based on robust neuro-fuzzy sliding approach. The photovoltaic energy produced by the PV generator will be completely injected on the network. Simulation results show that the system controlled by the neuro-fuzzy sliding adapts to changing external disturbances and show their effectiveness not only for continued maximum power point but also for response time and stability.

  3. A Modular PV System Using Chain-Link-Type Multilevel Converter

    NASA Astrophysics Data System (ADS)

    Hatano, Nobuhiko; Ise, Toshifumi

    This paper presents a modular photovoltaic system (MPVS) that uses a chain-link-type multilevel converter (CLMC). In large-scale PV generating systems, the DC power supply is generally composed of a large number of PV panels. Hence, losses are caused by differences in the maximum power point at each PV panel. An MPVS has been proposed to address the above mentioned problem. It helps improve the photoelectric conversion efficiency by applying maximum power point tracking (MPPT) control to each group of PV panels. In addition, if a CLMC is used in an MPVS, a high voltage can be output from the AC side and transmission losses can be decreased. However, with this circuit configuration, the current output from the AC side may be unbalanced. Therefore, we propose a method to output balanced current from the AC side, even if the output of the DC power supply is unbalanced. The validity of the proposed method is examined by digital simulation.

  4. A proposed adaptive step size perturbation and observation maximum power point tracking algorithm based on photovoltaic system modeling

    NASA Astrophysics Data System (ADS)

    Huang, Yu

    Solar energy becomes one of the major alternative renewable energy options for its huge abundance and accessibility. Due to the intermittent nature, the high demand of Maximum Power Point Tracking (MPPT) techniques exists when a Photovoltaic (PV) system is used to extract energy from the sunlight. This thesis proposed an advanced Perturbation and Observation (P&O) algorithm aiming for relatively practical circumstances. Firstly, a practical PV system model is studied with determining the series and shunt resistances which are neglected in some research. Moreover, in this proposed algorithm, the duty ratio of a boost DC-DC converter is the object of the perturbation deploying input impedance conversion to achieve working voltage adjustment. Based on the control strategy, the adaptive duty ratio step size P&O algorithm is proposed with major modifications made for sharp insolation change as well as low insolation scenarios. Matlab/Simulink simulation for PV model, boost converter control strategy and various MPPT process is conducted step by step. The proposed adaptive P&O algorithm is validated by the simulation results and detail analysis of sharp insolation changes, low insolation condition and continuous insolation variation.

  5. PSO Based PI Controller Design for a Solar Charger System

    PubMed Central

    Yau, Her-Terng; Lin, Chih-Jer; Liang, Qin-Cheng

    2013-01-01

    Due to global energy crisis and severe environmental pollution, the photovoltaic (PV) system has become one of the most important renewable energy sources. Many previous studies on solar charger integrated system only focus on load charge control or switching Maximum Power Point Tracking (MPPT) and charge control modes. This study used two-stage system, which allows the overall portable solar energy charging system to implement MPPT and optimal charge control of Li-ion battery simultaneously. First, this study designs a DC/DC boost converter of solar power generation, which uses variable step size incremental conductance method (VSINC) to enable the solar cell to track the maximum power point at any time. The voltage was exported from the DC/DC boost converter to the DC/DC buck converter, so that the voltage dropped to proper voltage for charging the battery. The charging system uses constant current/constant voltage (CC/CV) method to charge the lithium battery. In order to obtain the optimum PI charge controller parameters, this study used intelligent algorithm to determine the optimum parameters. According to the simulation and experimental results, the control parameters resulted from PSO have better performance than genetic algorithms (GAs). PMID:23766713

  6. PSO based PI controller design for a solar charger system.

    PubMed

    Yau, Her-Terng; Lin, Chih-Jer; Liang, Qin-Cheng

    2013-01-01

    Due to global energy crisis and severe environmental pollution, the photovoltaic (PV) system has become one of the most important renewable energy sources. Many previous studies on solar charger integrated system only focus on load charge control or switching Maximum Power Point Tracking (MPPT) and charge control modes. This study used two-stage system, which allows the overall portable solar energy charging system to implement MPPT and optimal charge control of Li-ion battery simultaneously. First, this study designs a DC/DC boost converter of solar power generation, which uses variable step size incremental conductance method (VSINC) to enable the solar cell to track the maximum power point at any time. The voltage was exported from the DC/DC boost converter to the DC/DC buck converter, so that the voltage dropped to proper voltage for charging the battery. The charging system uses constant current/constant voltage (CC/CV) method to charge the lithium battery. In order to obtain the optimum PI charge controller parameters, this study used intelligent algorithm to determine the optimum parameters. According to the simulation and experimental results, the control parameters resulted from PSO have better performance than genetic algorithms (GAs).

  7. Stable Adaptive Inertial Control of a Doubly-Fed Induction Generator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kang, Moses; Muljadi, Eduard; Hur, Kyeon

    2016-11-01

    This paper proposes a stable adaptive inertial control scheme of a doubly-fed induction generator. The proposed power reference is defined in two sections: the deceleration period and the acceleration period. The power reference in the deceleration period consists of a constant and the reference for maximum power point tracking (MPPT) operation. The latter contributes to preventing a second frequency dip (SFD) in this period because its reduction rate is large at the early stage of an event but quickly decreases with time. To improve the frequency nadir (FN), the constant value is set to be proportional to the rotor speedmore » prior to an event. The reference ensures that the rotor speed converges to a stable operating region. To accelerate the rotor speed while causing a small SFD, when the rotor speed converges, the power reference is reduced by a small amount and maintained until it meets the MPPT reference. The results show that the scheme causes a small SFD while improving the FN and the rate of change of frequency in any wind conditions, even in a grid that has a high penetration of wind power.« less

  8. An ultra-low power CMOS image sensor with on-chip energy harvesting and power management capability.

    PubMed

    Cevik, Ismail; Huang, Xiwei; Yu, Hao; Yan, Mei; Ay, Suat U

    2015-03-06

    An ultra-low power CMOS image sensor with on-chip energy harvesting and power management capability is introduced in this paper. The photodiode pixel array can not only capture images but also harvest solar energy. As such, the CMOS image sensor chip is able to switch between imaging and harvesting modes towards self-power operation. Moreover, an on-chip maximum power point tracking (MPPT)-based power management system (PMS) is designed for the dual-mode image sensor to further improve the energy efficiency. A new isolated P-well energy harvesting and imaging (EHI) pixel with very high fill factor is introduced. Several ultra-low power design techniques such as reset and select boosting techniques have been utilized to maintain a wide pixel dynamic range. The chip was designed and fabricated in a 1.8 V, 1P6M 0.18 µm CMOS process. Total power consumption of the imager is 6.53 µW for a 96 × 96 pixel array with 1 V supply and 5 fps frame rate. Up to 30 μW of power could be generated by the new EHI pixels. The PMS is capable of providing 3× the power required during imaging mode with 50% efficiency allowing energy autonomous operation with a 72.5% duty cycle.

  9. An Ultra-Low Power CMOS Image Sensor with On-Chip Energy Harvesting and Power Management Capability

    PubMed Central

    Cevik, Ismail; Huang, Xiwei; Yu, Hao; Yan, Mei; Ay, Suat U.

    2015-01-01

    An ultra-low power CMOS image sensor with on-chip energy harvesting and power management capability is introduced in this paper. The photodiode pixel array can not only capture images but also harvest solar energy. As such, the CMOS image sensor chip is able to switch between imaging and harvesting modes towards self-power operation. Moreover, an on-chip maximum power point tracking (MPPT)-based power management system (PMS) is designed for the dual-mode image sensor to further improve the energy efficiency. A new isolated P-well energy harvesting and imaging (EHI) pixel with very high fill factor is introduced. Several ultra-low power design techniques such as reset and select boosting techniques have been utilized to maintain a wide pixel dynamic range. The chip was designed and fabricated in a 1.8 V, 1P6M 0.18 µm CMOS process. Total power consumption of the imager is 6.53 µW for a 96 × 96 pixel array with 1 V supply and 5 fps frame rate. Up to 30 μW of power could be generated by the new EHI pixels. The PMS is capable of providing 3× the power required during imaging mode with 50% efficiency allowing energy autonomous operation with a 72.5% duty cycle. PMID:25756863

  10. High performance monolithic power management system with dynamic maximum power point tracking for microbial fuel cells.

    PubMed

    Erbay, Celal; Carreon-Bautista, Salvador; Sanchez-Sinencio, Edgar; Han, Arum

    2014-12-02

    Microbial fuel cell (MFC) that can directly generate electricity from organic waste or biomass is a promising renewable and clean technology. However, low power and low voltage output of MFCs typically do not allow directly operating most electrical applications, whether it is supplementing electricity to wastewater treatment plants or for powering autonomous wireless sensor networks. Power management systems (PMSs) can overcome this limitation by boosting the MFC output voltage and managing the power for maximum efficiency. We present a monolithic low-power-consuming PMS integrated circuit (IC) chip capable of dynamic maximum power point tracking (MPPT) to maximize the extracted power from MFCs, regardless of the power and voltage fluctuations from MFCs over time. The proposed PMS continuously detects the maximum power point (MPP) of the MFC and matches the load impedance of the PMS for maximum efficiency. The system also operates autonomously by directly drawing power from the MFC itself without any external power. The overall system efficiency, defined as the ratio between input energy from the MFC and output energy stored into the supercapacitor of the PMS, was 30%. As a demonstration, the PMS connected to a 240 mL two-chamber MFC (generating 0.4 V and 512 μW at MPP) successfully powered a wireless temperature sensor that requires a voltage of 2.5 V and consumes power of 85 mW each time it transmit the sensor data, and successfully transmitted a sensor reading every 7.5 min. The PMS also efficiently managed the power output of a lower-power producing MFC, demonstrating that the PMS works efficiently at various MFC power output level.

  11. Power Smoothing of a Variable-Speed Wind Turbine Generator in Association With the Rotor-Speed-Dependent Gain

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Yeonhee; Kang, Moses; Muljadi, Eduard

    This paper proposes a power-smoothing scheme for a variable-speed wind turbine generator (WTG) that can smooth out the WTG's fluctuating power caused by varying wind speeds, and thereby keep the system frequency within a narrow range. The proposed scheme employs an additional loop based on the system frequency deviation that operates in conjunction with the maximum power point tracking (MPPT) control loop. Unlike the conventional, fixed-gain scheme, its control gain is modified with the rotor speed. In the proposed scheme, the control gain is determined by considering the ratio of the output of the additional loop to that of themore » MPPT loop. To improve the contribution of the scheme toward maintaining the frequency while ensuring the stable operation of WTGs, in the low rotor speed region, the ratio is set to be proportional to the rotor speed; in the high rotor speed region, the ratio remains constant. The performance of the proposed scheme is investigated under varying wind conditions for the IEEE 14-bus system. The simulation results demonstrate that the scheme successfully operates regardless of the output power fluctuation of a WTG by adjusting the gain with the rotor speed, and thereby improves the frequency-regulating capability of a WTG.« less

  12. A control strategy for PV stand-alone applications

    NASA Astrophysics Data System (ADS)

    Slouma, S.; Baccar, H.

    2015-04-01

    This paper proposes a stand-alone photovoltaic (PV) system study in domestic applications. Because of the decrease in power of photovoltaic module as a consequence of changes in solar radiation and temperature which affect the photovoltaic module performance, the design and control of DC-DC buck converter was proposed for providing power to the load from a photovoltaic source.In fact, the control of this converter is carried out with integrated MPPT (Maximum Power Point Tracking) algorithm which ensures a maximum energy generated by the PV arrays. Moreover, the output stage is composed by a battery energy storage system, dc-ac inverter, LCL filter which enables higher efficiency, low distortion ac waveforms and low leakage currents. The control strategy adopted is cascade control composed by two regulation loops.Simulations performed with PSIM software were able to validate the control system.The realization and testing of the photovoltaic system were achieved in the Photovoltaic laboratory of the Centre for Research and Energy Technologies at the Technopark Borj Cedria. Experimental results verify the effeciency of the proposed system.

  13. PV based converter with integrated charger for DC micro-grid applications

    NASA Astrophysics Data System (ADS)

    Salve, Rima

    This thesis presents a converter topology for photovoltaic panels. This topology minimizes the number of switching devices used thereby reducing power losses that arise from high frequency switching operations. The control strategy is implemented using a simple microcontroller that implements the proportional plus integral control. All the control loops are closed feedback loops hence minimizing error instantaneously and adjusting efficiently to system variations. The energy management between three components, namely, the photovoltaic panel, a battery and a DC link for a microgrid is shown distributed over three modes. These modes are dependent on the irradiance from the sunlight. All three modes are simulated. The maximum power point tracking of the system plays a crutial role in this configuration as it is one of the main challenge tackled by the control system. Various methods of MPPT are discussed and the Perturb and Observe method is employed and is described in detail. Experimental results are shown for the maximum power point tracking of this system with a scaled down version of the panel's actual capability.

  14. Electrical Power Subsystem Integration and Test for the NPS Solar Cell Array Tester CubeSat

    DTIC Science & Technology

    2010-12-01

    Earth’s Gravitational Constant MCU Microcontroller Unit MPPT Maximum Power Point Tracker NiCr Nickel Chromium NPS Naval Postgraduate School P...new testing platform was designed, built, and used to conduct integrated testing on CubeSat Kit (CSK) compatible devices. The power budgets and...acceptance test results obtained from the testing platform were used with a solar array power generation simulation, and a battery state of charge

  15. Study of a thermoelectric system equipped with a maximum power point tracker for stand-alone electric generation.

    NASA Astrophysics Data System (ADS)

    Favarel, C.; Champier, D.; Bédécarrats, J. P.; Kousksou, T.; Strub, F.

    2012-06-01

    According to the International Energy Agency, 1.4 billion people are without electricity in the poorest countries and 2.5 billion people rely on biomass to meet their energy needs for cooking in developing countries. The use of cooking stoves equipped with small thermoelectric generator to provide electricity for basic needs (LED, cell phone and radio charging device) is probably a solution for houses far from the power grid. The cost of connecting every house with a landline is a lot higher than dropping thermoelectric generator in each house. Thermoelectric generators have very low efficiency but for isolated houses, they might become really competitive. Our laboratory works in collaboration with plane`te-bois (a non governmental organization) which has developed energy-efficient multifunction (cooking and hot water) stoves based on traditional stoves designs. A prototype of a thermoelectric generator (Bismuth Telluride) has been designed to convert a small part of the energy heating the sanitary water into electricity. This generator can produce up to 10 watts on an adapted load. Storing this energy in a battery is necessary as the cooking stove only works a few hours each day. As the working point of the stove varies a lot during the use it is also necessary to regulate the electrical power. An electric DC DC converter has been developed with a maximum power point tracker (MPPT) in order to have a good efficiency of the electronic part of the thermoelectric generator. The theoretical efficiency of the MMPT converter is discussed. First results obtained with a hot gas generator simulating the exhaust of the combustion chamber of a cooking stove are presented in the paper.

  16. A Study Examining Photovoltaic (PV) Solar Power as an Alternative for the Rebuilding of the Iraqi Electrical Power Generation Infrastructure

    DTIC Science & Technology

    2005-06-01

    Logistics, BA-5590, BB- 390, BB-2590, PVPC, Iraq, Power Grid, Infrastructure, Cost Estimate, Photovoltaic Power Conversion (PVPC), MPPT 16. PRICE...the cost and feasibility of using photovoltaic (PV) solar power to assist in the rebuilding of the Iraqi electrical infrastructure. This project...cost and feasibility of using photovoltaic (PV) solar power to assist in the rebuilding of the Iraqi infrastructure. The project examines available

  17. Comparison of Photovoltaic Energy Systems for the Solar Village

    DTIC Science & Technology

    1988-08-01

    power -point-trackIng ( MPPT ) for the array. It also Includes AC and DC contactors, an isolation transformer, and a control system that fully automates...the day when the array is producing power , the battery controller uses excess array power , not needed for household use , to recharge the batteries. As...alone design) The battery controller used Is the Balance of System Specialists, Inc. Power Control Series model *8104820 rated at 48 volt, 20 amp. This

  18. Multi-Layer Artificial Neural Networks Based MPPT-Pitch Angle Control of a Tidal Stream Generator

    PubMed Central

    Bouallègue, Soufiene; Garrido, Aitor J.; Haggège, Joseph

    2018-01-01

    Artificial intelligence technologies are widely investigated as a promising technique for tackling complex and ill-defined problems. In this context, artificial neural networks methodology has been considered as an effective tool to handle renewable energy systems. Thereby, the use of Tidal Stream Generator (TSG) systems aim to provide clean and reliable electrical power. However, the power captured from tidal currents is highly disturbed due to the swell effect and the periodicity of the tidal current phenomenon. In order to improve the quality of the generated power, this paper focuses on the power smoothing control. For this purpose, a novel Artificial Neural Network (ANN) is investigated and implemented to provide the proper rotational speed reference and the blade pitch angle. The ANN supervisor adequately switches the system in variable speed and power limitation modes. In order to recover the maximum power from the tides, a rotational speed control is applied to the rotor side converter following the Maximum Power Point Tracking (MPPT) generated from the ANN block. In case of strong tidal currents, a pitch angle control is set based on the ANN approach to keep the system operating within safe limits. Two study cases were performed to test the performance of the output power. Simulation results demonstrate that the implemented control strategies achieve a smoothed generated power in the case of swell disturbances. PMID:29695127

  19. Multi-Layer Artificial Neural Networks Based MPPT-Pitch Angle Control of a Tidal Stream Generator.

    PubMed

    Ghefiri, Khaoula; Bouallègue, Soufiene; Garrido, Izaskun; Garrido, Aitor J; Haggège, Joseph

    2018-04-24

    Artificial intelligence technologies are widely investigated as a promising technique for tackling complex and ill-defined problems. In this context, artificial neural networks methodology has been considered as an effective tool to handle renewable energy systems. Thereby, the use of Tidal Stream Generator (TSG) systems aim to provide clean and reliable electrical power. However, the power captured from tidal currents is highly disturbed due to the swell effect and the periodicity of the tidal current phenomenon. In order to improve the quality of the generated power, this paper focuses on the power smoothing control. For this purpose, a novel Artificial Neural Network (ANN) is investigated and implemented to provide the proper rotational speed reference and the blade pitch angle. The ANN supervisor adequately switches the system in variable speed and power limitation modes. In order to recover the maximum power from the tides, a rotational speed control is applied to the rotor side converter following the Maximum Power Point Tracking (MPPT) generated from the ANN block. In case of strong tidal currents, a pitch angle control is set based on the ANN approach to keep the system operating within safe limits. Two study cases were performed to test the performance of the output power. Simulation results demonstrate that the implemented control strategies achieve a smoothed generated power in the case of swell disturbances.

  20. A Case Analysis of Energy Savings Performance Contract Projects and Photovoltaic Energy at Fort Bliss, El Paso, Texas

    DTIC Science & Technology

    2006-06-01

    PHOTOVOLTAIC ENERGY AND FORT BLISS CASE BACKGROUND A. PHOTOVOLTAIC ENERGY The use of photovoltaic power systems is nothing new in the Department...against the Outback MPPT charge controller . This test will be done over a one month timeframe. The Arizona Power ISG test plan is contained in...cost-benefit analysis of conventional power versus emerging photovoltaic energy for the Army’s Fort Bliss in El Paso, TX. The project will also analyze

  1. The Modification of HOMER Software Application to Provide the United States Marine Corps with an Energy Planning Tool

    DTIC Science & Technology

    2012-12-01

    circuit used to discharge LiFePO4 batteries. .................84  Figure 33.  The PSPICE model of our constant current circuit...Ion Battery LiFePO4 Lithium Iron Phosphate xviii MEP Mobile Electric Power MP Maximum Power MPPT Maximum Power Point Tracker NASA National...GREENS). GREENS has eight large 200-W solar panels, four Lithium Iron Phosphate ( LiFePO4 ) batteries, and an integrated controller. GREENS is not

  2. Maximum Power Point Tracking Control of Hydrokinetic Turbine and Low-speed High-Thrust Permanent Magnet Generator Design

    DTIC Science & Technology

    2012-01-01

    Schematic of the generator and power converters built in PLECS ............. 26 Figure 3.12. Block diagram of the MPPT control built in Matlab/Simulink...validated by simulation results done in Matlab/Simulink R2010a and PLECS . Figure 3.9 shows the block diagram of the hydrokinetic system built in Matlab...rectifier, boost converter and battery model built in PLECS . The battery bank on the load side is simulated by a constant dc voltage source. 25

  3. Design of a Maximum Power Point Tracker with Simulation, Analysis, and Comparison of Algorithms

    DTIC Science & Technology

    2012-12-01

    BLANK xxvi CHAPTER 1: INTRODUCTION It is a warm summer day. You feel the sun warm your skin and rejuvenate your motiva- tion. The sun generates more... renewable , there has been an upsurge of interest in clean and renewable energy. While more than one option is available to fill that void, the most...solar array. When this algorithm is functioning correctly, it is said to be an MPPT . 1.2 Motivation Clean and renewable energy has greatly increased

  4. Fuzzy logic control of stand-alone photovoltaic system with battery storage

    NASA Astrophysics Data System (ADS)

    Lalouni, S.; Rekioua, D.; Rekioua, T.; Matagne, E.

    Photovoltaic energy has nowadays an increased importance in electrical power applications, since it is considered as an essentially inexhaustible and broadly available energy resource. However, the output power provided via the photovoltaic conversion process depends on solar irradiation and temperature. Therefore, to maximize the efficiency of the photovoltaic energy system, it is necessary to track the maximum power point of the PV array. The present paper proposes a maximum power point tracker (MPPT) method, based on fuzzy logic controller (FLC), applied to a stand-alone photovoltaic system. It uses a sampling measure of the PV array power and voltage then determines an optimal increment required to have the optimal operating voltage which permits maximum power tracking. This method carries high accuracy around the optimum point when compared to the conventional one. The stand-alone photovoltaic system used in this paper includes two bi-directional DC/DC converters and a lead-acid battery bank to overcome the scare periods. One converter works as an MPP tracker, while the other regulates the batteries state of charge and compensates the power deficit to provide a continuous delivery of energy to the load. The Obtained simulation results show the effectiveness of the proposed fuzzy logic controller.

  5. One-power IC with MPPT design

    NASA Astrophysics Data System (ADS)

    Xu, Shengzhi; Chu, Ian; Zhao, Gengshen; Wang, Qingzhang

    2008-03-01

    When proceed photovoltaic power system design, engineer needs prepared model of PV cells to evaluate system response, capability performance, and stability, the DC model is not enough, but an accuracy AC model plays a big role. This paper talks first about the AC model of PV cells, and DC model is also introduced in simple. There is a PV controller example explaining the steps to do system simulation in this paper. Two equivalent circuit models are implemented with mixed-signal language verilog-a, one hardware language easy to use and having good speed and high accuracy. Both of two models include solar cell arrays, one buck switched mode DC-DC converter, and the maximum power point tracking algorithm. The difference between them is that Solar cell in one of two models is with ac small signal parameter, another is without. The simulation result is given in comparison. This paper's work shows that ac parameter plays large role in switch-mode PV power system, especially when the switch frequency is higher than 100kHz.

  6. Robust fractional order sliding mode control of doubly-fed induction generator (DFIG)-based wind turbines.

    PubMed

    Ebrahimkhani, Sadegh

    2016-07-01

    Wind power plants have nonlinear dynamics and contain many uncertainties such as unknown nonlinear disturbances and parameter uncertainties. Thus, it is a difficult task to design a robust reliable controller for this system. This paper proposes a novel robust fractional-order sliding mode (FOSM) controller for maximum power point tracking (MPPT) control of doubly fed induction generator (DFIG)-based wind energy conversion system. In order to enhance the robustness of the control system, uncertainties and disturbances are estimated using a fractional order uncertainty estimator. In the proposed method a continuous control strategy is developed to achieve the chattering free fractional order sliding-mode control, and also no knowledge of the uncertainties and disturbances or their bound is assumed. The boundedness and convergence properties of the closed-loop signals are proven using Lyapunov׳s stability theory. Simulation results in the presence of various uncertainties were carried out to evaluate the effectiveness and robustness of the proposed control scheme. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  7. Solar power plant performance evaluation: simulation and experimental validation

    NASA Astrophysics Data System (ADS)

    Natsheh, E. M.; Albarbar, A.

    2012-05-01

    In this work the performance of solar power plant is evaluated based on a developed model comprise photovoltaic array, battery storage, controller and converters. The model is implemented using MATLAB/SIMULINK software package. Perturb and observe (P&O) algorithm is used for maximizing the generated power based on maximum power point tracker (MPPT) implementation. The outcome of the developed model are validated and supported by a case study carried out using operational 28.8kW grid-connected solar power plant located in central Manchester. Measurements were taken over 21 month's period; using hourly average irradiance and cell temperature. It was found that system degradation could be clearly monitored by determining the residual (the difference) between the output power predicted by the model and the actual measured power parameters. It was found that the residual exceeded the healthy threshold, 1.7kW, due to heavy snow in Manchester last winter. More important, the developed performance evaluation technique could be adopted to detect any other reasons that may degrade the performance of the P V panels such as shading and dirt. Repeatability and reliability of the developed system performance were validated during this period. Good agreement was achieved between the theoretical simulation and the real time measurement taken the online grid connected solar power plant.

  8. A Method of Maximum Power Control in Single-phase Utility Interactive Photovoltaic Generation System by using PWM Current Source Inverter

    NASA Astrophysics Data System (ADS)

    Neba, Yasuhiko

    This paper deals with a maximum power point tracking (MPPT) control of the photovoltaic generation with the single-phase utility interactive inverter. The photovoltaic arrays are connected by employing the PWM current source inverter to the utility. The use of the pulsating dc current and voltage allows the maximum power point to be searched. The inverter can regulate the array voltage and keep the arrays to the maximum power. This paper gives the control method and the experimental results.

  9. Adaptive control for solar energy based DC microgrid system development

    NASA Astrophysics Data System (ADS)

    Zhang, Qinhao

    During the upgrading of current electric power grid, it is expected to develop smarter, more robust and more reliable power systems integrated with distributed generations. To realize these objectives, traditional control techniques are no longer effective in either stabilizing systems or delivering optimal and robust performances. Therefore, development of advanced control methods has received increasing attention in power engineering. This work addresses two specific problems in the control of solar panel based microgrid systems. First, a new control scheme is proposed for the microgrid systems to achieve optimal energy conversion ratio in the solar panels. The control system can optimize the efficiency of the maximum power point tracking (MPPT) algorithm by implementing two layers of adaptive control. Such a hierarchical control architecture has greatly improved the system performance, which is validated through both mathematical analysis and computer simulation. Second, in the development of the microgrid transmission system, the issues related to the tele-communication delay and constant power load (CPL)'s negative incremental impedance are investigated. A reference model based method is proposed for pole and zero placements that address the challenges of the time delay and CPL in closed-loop control. The effectiveness of the proposed modeling and control design methods are demonstrated in a simulation testbed. Practical aspects of the proposed methods for general microgrid systems are also discussed.

  10. Developing a stability assessment method for power electronics-based microgrids

    NASA Astrophysics Data System (ADS)

    Austin, Peter M.

    Modern microgrids with microsources and energy storage are dependent on power electronics for control and regulation. Under certain circumstances power electronics can be destabilizing to the system due to an effect called negative incremental impedance. A careful review of the theory and literature on the subject is presented. This includes stability criteria for both AC and DC systems, as well as a discussion on the limitations posed by the analysis. A method to integrate stability assessment with higher-level microgrid architectural design is proposed. Crucial to this is impedance characterization of individual components, which was accomplished through simulation. DC and AC impedance measurement blocks were created in Matlab simulink to automate the process. A detailed switching-level model of a DC microgrid was implemented in simulink, including wind turbine microsource, battery storage, and three phase inverter. Maximum power point tracking (MPPT) was included to maximize the efficiency of the turbine and was implemented through three rectifier alternatives and control schemes. The stability characteristics of each was compared in the final analysis. Impedance data was collected individually from the components and used to assess stability in the system as a whole. The results included the assessment of stability, margin, and unstable operating points to demonstrate the feasibility of the proposed approach.

  11. A MPPT Algorithm Based PV System Connected to Single Phase Voltage Controlled Grid

    NASA Astrophysics Data System (ADS)

    Sreekanth, G.; Narender Reddy, N.; Durga Prasad, A.; Nagendrababu, V.

    2012-10-01

    Future ancillary services provided by photovoltaic (PV) systems could facilitate their penetration in power systems. In addition, low-power PV systems can be designed to improve the power quality. This paper presents a single-phase PV systemthat provides grid voltage support and compensation of harmonic distortion at the point of common coupling thanks to a repetitive controller. The power provided by the PV panels is controlled by a Maximum Power Point Tracking algorithm based on the incremental conductance method specifically modified to control the phase of the PV inverter voltage. Simulation and experimental results validate the presented solution.

  12. 3D Printing the Complete CubeSat

    NASA Technical Reports Server (NTRS)

    Kief, Craig

    2015-01-01

    The 3D Printing the Complete CubeSat project is designed to advance the state-of-the-art in 3D printing for CubeSat applications. Printing in 3D has the potential to increase reliability, reduce design iteration time and provide greater design flexibility in the areas of radiation mitigation, communications, propulsion, and wiring, among others. This project is investigating the possibility of including propulsion systems into the design of printed CubeSat components. One such concept, an embedded micro pulsed plasma thruster (mPPT), could provide auxiliary reaction control propulsion for a spacecraft as a means to desaturate momentum wheels.

  13. Investigation Results on Solar Array Thermal & Electrical Imbalance Phenomenon on Power Systems Equipped with MPPT

    NASA Astrophysics Data System (ADS)

    Mercier, F.; Samaniego, B.; Soriano, T.; Beaufils, G.; Fernandez Lisbona, E.; Dettlaff, K.; Jensen, H.

    2014-08-01

    The thermal / electrical imbalance phenomenon on the satellite solar arrays is a common issue inherent to the negative thermal voltage coefficient of the triple junction cells, which is usually already taken into account with basic precautions on the solar panel layout.In the frame of the ESA TRP study "Investigation on Solar Array thermal and electrical imbalance phenomenon on power systems equipped with Maximum Power Point Tracker (MPPT)" performed by Airbus Defence & Space (former Astrium Toulouse and Ottobrunn) and TERMA, in-depth analyses were conducted for the first time to better understand and characterize the secondary maximum power point phenomenon for various representative mission cases, whether in Earth vicinity or not. With the help of a newly developed detailed thermo-electrical coupled solver and a wide range of solar cell characterizations in flux and temperature, multiple sets of simulations were run to simulate realistic solar panel characteristics.The study showed that no secondary false maximum power point can be created on the solar panel characteristic IV curve for missions around Earth vicinity, at the sole exception of critical shadowing cases. Furthermore, the same conclusions apply for missions up to Mars orbit. The only potential threats come from the missions further than Mars (typically Jupiter missions) where various very high heterogeneities could lead to multiple maxima. This is deeply linked to the LILT (low illumination low temperature) conditions applied to the current solar cell triple junction characteristics and shape. Moreover, thermo-electrical imbalances that do not create secondary power point can still seriously grieve the solar array power output performances. This power loss can however be accurately assessed by the newly developed solver in support of in-development missions like Juice.

  14. Grid-connected wind and photovoltaic system

    NASA Astrophysics Data System (ADS)

    Devabakthuni, Sindhuja

    The objective of this thesis is to design a grid connected wind and photovoltaic system. A new model of converter control was designed which maintains the voltage of the bus to grid as constant when combined system of solar and wind is connected to AC bus. The model is designed to track maximum power at each point irrespective of changes in irradiance, temperature and wind speed which affects the power supplied to grid. Solar power from the sun is not constant as it is affected by changes in irradiances and temperature. Even the wind power is affected by wind speed. A MPPT controller was designed for both systems. A boost converter is designed which uses the pulses from MPPT controller to boost the output. Wind system consists of wind turbine block from the MATLAB with a pitch angle controller to maintain optimum pitch angle. The output from wind turbine is connected to a permanent magnet synchronous generator. The unregulated DC output from the photovoltaic system is directly given to boost converter. The AC output from the wind system is given to an uncontrolled rectifier to get a unregulated DC output. The unregulated DC output goes to the boost converter. A voltage source inverter was designed which converts the rectified DC output from the boost converter to AC power. The inverter is designed to maintain constant AC bus voltage irrespective of the disturbances in the power supply. Photovoltaic and wind systems are individually designed for 5KW each in MATLAB-Simulink environment. In this thesis, the models were subjected to changes in irradiance, temperature and wind speed and the results were interpreted. The model was successful in tracking maximum at every instant and the AC bus voltage was maintained constant throughout the simulation.

  15. Piezoelectric energy harvester interface with real-time MPPT

    NASA Astrophysics Data System (ADS)

    Elliott, A. D. T.; Mitcheson, P. D.

    2014-11-01

    Power of resonant piezoelectric harvesters can be severely limited if the damping force cannot be dynamically altered as the mechanical excitation level changes. The singlesupply pre-biasing (SSPB) technique enables the Coulomb damping force to be set by a single voltage and so by varying that voltage, real-time adaptation to variations in the mechanical force can be implemented. Similarly the conduction angle of a diode bridge rectifier circuit can be altered by changing the biasing voltage applied. This paper presents a method of achieving this by altering the amount of energy transferred from the pre-biasing capacitor used in SSPB and the diode bridge rectifier to a storage battery via a buck converter. The control system was implemented on a FPGA and consumed 50 μW.

  16. Direct torque control method applied to the WECS based on the PMSG and controlled with backstepping approach

    NASA Astrophysics Data System (ADS)

    Errami, Youssef; Obbadi, Abdellatif; Sahnoun, Smail; Ouassaid, Mohammed; Maaroufi, Mohamed

    2018-05-01

    This paper proposes a Direct Torque Control (DTC) method for Wind Power System (WPS) based Permanent Magnet Synchronous Generator (PMSG) and Backstepping approach. In this work, generator side and grid-side converter with filter are used as the interface between the wind turbine and grid. Backstepping approach demonstrates great performance in complicated nonlinear systems control such as WPS. So, the control method combines the DTC to achieve Maximum Power Point Tracking (MPPT) and Backstepping approach to sustain the DC-bus voltage and to regulate the grid-side power factor. In addition, control strategy is developed in the sense of Lyapunov stability theorem for the WPS. Simulation results using MATLAB/Simulink validate the effectiveness of the proposed controllers.

  17. Study of Stand-Alone Microgrid under Condition of Faults on Distribution Line

    NASA Astrophysics Data System (ADS)

    Malla, S. G.; Bhende, C. N.

    2014-10-01

    The behavior of stand-alone microgrid is analyzed under the condition of faults on distribution feeders. During fault since battery is not able to maintain dc-link voltage within limit, the resistive dump load control is presented to do so. An inverter control is proposed to maintain balanced voltages at PCC under the unbalanced load condition and to reduce voltage unbalance factor (VUF) at load points. The proposed inverter control also has facility to protect itself from high fault current. Existing maximum power point tracker (MPPT) algorithm is modified to limit the speed of generator during fault. Extensive simulation results using MATLAB/SIMULINK established that the performance of the controllers is quite satisfactory under different fault conditions as well as unbalanced load conditions.

  18. Exploring the Use of the LT3480 (RH3480) Circuit as Low-Power, Low-Voltage Solar Array Regulator

    NASA Astrophysics Data System (ADS)

    Garrigos, A.; Lizan, J. L.; Blanes, J. M.; Gutierrez, R.

    2014-08-01

    With the advent of PoL technology, several commercial integrated switching regulators already have their space- qualified versions. Apart of PoL and secondary supply applications, other functions can be explored using those integrated circuits. In this work, the Solar Array Regulator function is analyzed using the commercial LT3480 circuit, which has the space counterpart (RH3480) commercialized by MSK and named MSK5058RH and later MSK5031 (but not rad-hard). Input voltage regulation, taper charge, protection functions and module parallelization are studied and verified experimentally in a low-voltage, low-power MPPT battery bus configuration. Potential users of this approach are micro and nano-satellites power systems.

  19. Design and realization of an autonomous solar system

    NASA Astrophysics Data System (ADS)

    Gaga, A.; Diouri, O.; Es-sbai, N.; Errahimi, F.

    2017-03-01

    The aim of this work is the design and realization of an autonomous solar system, with MPPT control, a regulator charge/discharge of batteries, an H-bridge multi-level inverter with acquisition system and supervising based on a microcontroller. The proposed approach is based on developing a software platform in the LabVIEW environment which gives the system a flexible structure for controlling, monitoring and supervising the whole system in real time while providing power maximization and best quality of energy conversion from DC to AC power. The reliability of the proposed solar system is validated by the simulation results on PowerSim and experimental results achieved with a solar panel, a Lead acid battery, solar regulator and an H-bridge cascaded topology of single-phase inverter.

  20. Adaptive control paradigm for photovoltaic and solid oxide fuel cell in a grid-integrated hybrid renewable energy system.

    PubMed

    Mumtaz, Sidra; Khan, Laiq

    2017-01-01

    The hybrid power system (HPS) is an emerging power generation scheme due to the plentiful availability of renewable energy sources. Renewable energy sources are characterized as highly intermittent in nature due to meteorological conditions, while the domestic load also behaves in a quite uncertain manner. In this scenario, to maintain the balance between generation and load, the development of an intelligent and adaptive control algorithm has preoccupied power engineers and researchers. This paper proposes a Hermite wavelet embedded NeuroFuzzy indirect adaptive MPPT (maximum power point tracking) control of photovoltaic (PV) systems to extract maximum power and a Hermite wavelet incorporated NeuroFuzzy indirect adaptive control of Solid Oxide Fuel Cells (SOFC) to obtain a swift response in a grid-connected hybrid power system. A comprehensive simulation testbed for a grid-connected hybrid power system (wind turbine, PV cells, SOFC, electrolyzer, battery storage system, supercapacitor (SC), micro-turbine (MT) and domestic load) is developed in Matlab/Simulink. The robustness and superiority of the proposed indirect adaptive control paradigm are evaluated through simulation results in a grid-connected hybrid power system testbed by comparison with a conventional PI (proportional and integral) control system. The simulation results verify the effectiveness of the proposed control paradigm.

  1. Adaptive control paradigm for photovoltaic and solid oxide fuel cell in a grid-integrated hybrid renewable energy system

    PubMed Central

    Khan, Laiq

    2017-01-01

    The hybrid power system (HPS) is an emerging power generation scheme due to the plentiful availability of renewable energy sources. Renewable energy sources are characterized as highly intermittent in nature due to meteorological conditions, while the domestic load also behaves in a quite uncertain manner. In this scenario, to maintain the balance between generation and load, the development of an intelligent and adaptive control algorithm has preoccupied power engineers and researchers. This paper proposes a Hermite wavelet embedded NeuroFuzzy indirect adaptive MPPT (maximum power point tracking) control of photovoltaic (PV) systems to extract maximum power and a Hermite wavelet incorporated NeuroFuzzy indirect adaptive control of Solid Oxide Fuel Cells (SOFC) to obtain a swift response in a grid-connected hybrid power system. A comprehensive simulation testbed for a grid-connected hybrid power system (wind turbine, PV cells, SOFC, electrolyzer, battery storage system, supercapacitor (SC), micro-turbine (MT) and domestic load) is developed in Matlab/Simulink. The robustness and superiority of the proposed indirect adaptive control paradigm are evaluated through simulation results in a grid-connected hybrid power system testbed by comparison with a conventional PI (proportional and integral) control system. The simulation results verify the effectiveness of the proposed control paradigm. PMID:28329015

  2. Fault detection and diagnosis of photovoltaic systems

    NASA Astrophysics Data System (ADS)

    Wu, Xing

    The rapid growth of the solar industry over the past several years has expanded the significance of photovoltaic (PV) systems. One of the primary aims of research in building-integrated PV systems is to improve the performance of the system's efficiency, availability, and reliability. Although much work has been done on technological design to increase a photovoltaic module's efficiency, there is little research so far on fault diagnosis for PV systems. Faults in a PV system, if not detected, may not only reduce power generation, but also threaten the availability and reliability, effectively the "security" of the whole system. In this paper, first a circuit-based simulation baseline model of a PV system with maximum power point tracking (MPPT) is developed using MATLAB software. MATLAB is one of the most popular tools for integrating computation, visualization and programming in an easy-to-use modeling environment. Second, data collection of a PV system at variable surface temperatures and insolation levels under normal operation is acquired. The developed simulation model of PV system is then calibrated and improved by comparing modeled I-V and P-V characteristics with measured I--V and P--V characteristics to make sure the simulated curves are close to those measured values from the experiments. Finally, based on the circuit-based simulation model, a PV model of various types of faults will be developed by changing conditions or inputs in the MATLAB model, and the I--V and P--V characteristic curves, and the time-dependent voltage and current characteristics of the fault modalities will be characterized for each type of fault. These will be developed as benchmark I-V or P-V, or prototype transient curves. If a fault occurs in a PV system, polling and comparing actual measured I--V and P--V characteristic curves with both normal operational curves and these baseline fault curves will aid in fault diagnosis.

  3. An improved maximum power point tracking method for a photovoltaic system

    NASA Astrophysics Data System (ADS)

    Ouoba, David; Fakkar, Abderrahim; El Kouari, Youssef; Dkhichi, Fayrouz; Oukarfi, Benyounes

    2016-06-01

    In this paper, an improved auto-scaling variable step-size Maximum Power Point Tracking (MPPT) method for photovoltaic (PV) system was proposed. To achieve simultaneously a fast dynamic response and stable steady-state power, a first improvement was made on the step-size scaling function of the duty cycle that controls the converter. An algorithm was secondly proposed to address wrong decision that may be made at an abrupt change of the irradiation. The proposed auto-scaling variable step-size approach was compared to some various other approaches from the literature such as: classical fixed step-size, variable step-size and a recent auto-scaling variable step-size maximum power point tracking approaches. The simulation results obtained by MATLAB/SIMULINK were given and discussed for validation.

  4. Modeling, control, and simulation of grid connected intelligent hybrid battery/photovoltaic system using new hybrid fuzzy-neural method.

    PubMed

    Rezvani, Alireza; Khalili, Abbas; Mazareie, Alireza; Gandomkar, Majid

    2016-07-01

    Nowadays, photovoltaic (PV) generation is growing increasingly fast as a renewable energy source. Nevertheless, the drawback of the PV system is its dependence on weather conditions. Therefore, battery energy storage (BES) can be considered to assist for a stable and reliable output from PV generation system for loads and improve the dynamic performance of the whole generation system in grid connected mode. In this paper, a novel topology of intelligent hybrid generation systems with PV and BES in a DC-coupled structure is presented. Each photovoltaic cell has a specific point named maximum power point on its operational curve (i.e. current-voltage or power-voltage curve) in which it can generate maximum power. Irradiance and temperature changes affect these operational curves. Therefore, the nonlinear characteristic of maximum power point to environment has caused to development of different maximum power point tracking techniques. In order to capture the maximum power point (MPP), a hybrid fuzzy-neural maximum power point tracking (MPPT) method is applied in the PV system. Obtained results represent the effectiveness and superiority of the proposed method, and the average tracking efficiency of the hybrid fuzzy-neural is incremented by approximately two percentage points in comparison to the conventional methods. It has the advantages of robustness, fast response and good performance. A detailed mathematical model and a control approach of a three-phase grid-connected intelligent hybrid system have been proposed using Matlab/Simulink. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  5. Solar Photovoltaic (PV) Distributed Generation Systems - Control and Protection

    NASA Astrophysics Data System (ADS)

    Yi, Zhehan

    This dissertation proposes a comprehensive control, power management, and fault detection strategy for solar photovoltaic (PV) distribution generations. Battery storages are typically employed in PV systems to mitigate the power fluctuation caused by unstable solar irradiance. With AC and DC loads, a PV-battery system can be treated as a hybrid microgrid which contains both DC and AC power resources and buses. In this thesis, a control power and management system (CAPMS) for PV-battery hybrid microgrid is proposed, which provides 1) the DC and AC bus voltage and AC frequency regulating scheme and controllers designed to track set points; 2) a power flow management strategy in the hybrid microgrid to achieve system generation and demand balance in both grid-connected and islanded modes; 3) smooth transition control during grid reconnection by frequency and phase synchronization control between the main grid and microgrid. Due to the increasing demands for PV power, scales of PV systems are getting larger and fault detection in PV arrays becomes challenging. High-impedance faults, low-mismatch faults, and faults occurred in low irradiance conditions tend to be hidden due to low fault currents, particularly, when a PV maximum power point tracking (MPPT) algorithm is in-service. If remain undetected, these faults can considerably lower the output energy of solar systems, damage the panels, and potentially cause fire hazards. In this dissertation, fault detection challenges in PV arrays are analyzed in depth, considering the crossing relations among the characteristics of PV, interactions with MPPT algorithms, and the nature of solar irradiance. Two fault detection schemes are then designed as attempts to address these technical issues, which detect faults inside PV arrays accurately even under challenging circumstances, e.g., faults in low irradiance conditions or high-impedance faults. Taking advantage of multi-resolution signal decomposition (MSD), a powerful signal processing technique based on discrete wavelet transformation (DWT), the first attempt is devised, which extracts the features of both line-to-line (L-L) and line-to-ground (L-G) faults and employs a fuzzy inference system (FIS) for the decision-making stage of fault detection. This scheme is then improved as the second attempt by further studying the system's behaviors during L-L faults, extracting more efficient fault features, and devising a more advanced decision-making stage: the two-stage support vector machine (SVM). For the first time, the two-stage SVM method is proposed in this dissertation to detect L-L faults in PV system with satisfactory accuracies. Numerous simulation and experimental case studies are carried out to verify the proposed control and protection strategies. Simulation environment is set up using the PSCAD/EMTDC and Matlab/Simulink software packages. Experimental case studies are conducted in a PV-battery hybrid microgrid using the dSPACE real-time controller to demonstrate the ease of hardware implementation and the controller performance. Another small-scale grid-connected PV system is set up to verify both fault detection algorithms which demonstrate promising performances and fault detecting accuracies.

  6. Investigation on the Maximum Power Point in Solar Panel Characteristics Due to Irradiance Changes

    NASA Astrophysics Data System (ADS)

    Abdullah, M. A.; Fauziah Toha, Siti; Ahmad, Salmiah

    2017-03-01

    One of the disadvantages of the photovoltaic module as compared to other renewable resources is the dynamic characteristics of solar irradiance due to inconsistency weather condition and surrounding temperature. Commonly, a photovoltaic power generation systems consist of an embedded control system to maximize the power generation due to the inconsistency in irradiance. In order to improve the simplicity of the power optimization control, this paper present the characteristic of Maximum Power Point with various irradiance levels for Maximum Power Point Tracking (MPPT). The technique requires a set of data from photovoltaic simulation model to be extrapolated as a standard relationship between irradiance and maximum power. The result shows that the relationship between irradiance and maximum power can be represented by a simplified quadratic equation. The first section in your paper

  7. Controllers for Battery Chargers and Battery Chargers Therefrom

    NASA Technical Reports Server (NTRS)

    Elmes, John (Inventor); Kersten, Rene (Inventor); Pepper, Michael (Inventor)

    2014-01-01

    A controller for a battery charger that includes a power converter has parametric sensors for providing a sensed Vin signal, a sensed Vout signal and a sensed Iout signal. A battery current regulator (BCR) is coupled to receive the sensed Iout signal and an Iout reference, and outputs a first duty cycle control signal. An input voltage regulator (IVR) receives the sensed Vin signal and a Vin reference. The IVR provides a second duty cycle control signal. A processor receives the sensed Iout signal and utilizes a Maximum Power Point Tracking (MPPT) algorithm, and provides the Vin reference to the IVR. A selection block forwards one of the first and second duty cycle control signals as a duty cycle control signal to the power converter. Dynamic switching between the first and second duty cycle control signals maximizes the power delivered to the battery.

  8. Optimal tracking and second order sliding power control of the DFIG wind turbine

    NASA Astrophysics Data System (ADS)

    Abdeddaim, S.; Betka, A.; Charrouf, O.

    2017-02-01

    In the present paper, an optimal operation of a grid-connected variable speed wind turbine equipped with a Doubly Fed Induction Generator (DFIG) is presented. The proposed cascaded nonlinear controller is designed to perform two main objectives. In the outer loop, a maximum power point tracking (MPPT) algorithm based on fuzzy logic theory is designed to permanently extract the optimal aerodynamic energy, whereas in the inner loop, a second order sliding mode control (2-SM) is applied to achieve smooth regulation of both stator active and reactive powers quantities. The obtained simulation results show a permanent track of the MPP point regardless of the turbine power-speed slope moreover the proposed sliding mode control strategy presents attractive features such as chattering-free, compared to the conventional first order sliding technique (1-SM).

  9. Research on Experiment of Islanding Protection Device of Grid-connected Photovoltaic System Based on RTDS

    NASA Astrophysics Data System (ADS)

    Zhou, Ning; Yang, Jia; Cheng, Zheng; Chen, Bo; Su, Yong Chun; Shu, Zhan; Zou, Jin

    2017-06-01

    Solar photovoltaic power generation is the power generation using solar cell module converting sunlight into DC electric energy. In the paper an equivalent model of solar photovoltaic power generation system is built in RTDS. The main circuit structure of the two-stage PV grid-connected system consists of the DC-DC, DC-AC circuit. The MPPT (Maximum Power Point Tracking) control of the PV array is controlled by adjusting the duty ratio of the DC-DC circuit. The proposed control strategy of constant voltage/constant reactive power (V/Q) control is successfully implemented grid-connected control of the inverter when grid-connected operation. The closed-loop experiment of islanding protection device of photovoltaic power plant on RTDS, verifies the correctness of the simulation model, and the experimental verification can be applied to this type of device.

  10. Power conversion and control methods for renewable energy sources

    NASA Astrophysics Data System (ADS)

    Yu, Dachuan

    2005-07-01

    In recent years, there has been an increase in the use of renewable energy due to the growing concern over the pollution caused by fossil-fuel-based energy. Renewable energy sources, such as photovoltaic (PV) and fuel cell, can be used to enhance the safety, reliability, sustainability, and transmission efficiency of a power system. This dissertation focuses on the power conversion and control for two major renewable-energy sources: PV and fuel cell. Firstly, a current-based, maximum power-point tracking (MPPT) algorithm is proposed for PV energy. An economical converter system using the above scheme for converting the output from PV panels into 60 Hz AC voltage is developed and built. Secondly, a novel circuit model for the Proton Exchange Membrane (PEM) fuel-cell stack that is useful in the design and analysis of fuel-cell-based power systems is proposed. This Pspice-based model uses elements available in the Pspice library with some modifications to represent both the static and dynamic responses of a PEM fuel-cell module. The accuracy of the model is verified by comparing the simulation and experimental results. Thirdly, a DSP-controlled three-phase induction-motor drive using constant voltage over frequency is built and can be used in a fuel-cell automobile. A hydrogen sensor is used in the drive to both sound an alarm and shut down the inverter trigger pulses through the DSP. Finally, a hybrid power system consisting of PV panels and fuel cell is proposed and built. In the proposed system, PV panels can supply most of the power when the sunlight is available, and the excess power required by the load is supplied by a fuel cell. Load sharing between a fuel cell (FC) and the PV panel is investigated by both simulation and experiments.

  11. Dynamic performance of maximum power point tracking circuits using sinusoidal extremum seeking control for photovoltaic generation

    NASA Astrophysics Data System (ADS)

    Leyva, R.; Artillan, P.; Cabal, C.; Estibals, B.; Alonso, C.

    2011-04-01

    The article studies the dynamic performance of a family of maximum power point tracking circuits used for photovoltaic generation. It revisits the sinusoidal extremum seeking control (ESC) technique which can be considered as a particular subgroup of the Perturb and Observe algorithms. The sinusoidal ESC technique consists of adding a small sinusoidal disturbance to the input and processing the perturbed output to drive the operating point at its maximum. The output processing involves a synchronous multiplication and a filtering stage. The filter instance determines the dynamic performance of the MPPT based on sinusoidal ESC principle. The approach uses the well-known root-locus method to give insight about damping degree and settlement time of maximum-seeking waveforms. This article shows the transient waveforms in three different filter instances to illustrate the approach. Finally, an experimental prototype corroborates the dynamic analysis.

  12. A New MPPT Control for Photovoltaic Panels by Instantaneous Maximum Power Point Tracking

    NASA Astrophysics Data System (ADS)

    Tokushima, Daiki; Uchida, Masato; Kanbei, Satoshi; Ishikawa, Hiroki; Naitoh, Haruo

    This paper presents a new maximum power point tracking control for photovoltaic (PV) panels. The control can be categorized into the Perturb and Observe (P & O) method. It utilizes instantaneous voltage ripples at PV panel output terminals caused by the switching of a chopper connected to the panel in order to identify the direction for the maximum power point (MPP). The tracking for the MPP is achieved by a feedback control of the average terminal voltage of the panel. Appropriate use of the instantaneous and the average values of the PV voltage for the separate purposes enables both the quick transient response and the good convergence with almost no ripples simultaneously. The tracking capability is verified experimentally with a 2.8 W PV panel under a controlled experimental setup. A numerical comparison with a conventional P & O confirms that the proposed control extracts much more power from the PV panel.

  13. Optimal model of PDIG based microgrid and design of complementary stabilizer using ICA.

    PubMed

    Amini, R Mohammad; Safari, A; Ravadanegh, S Najafi

    2016-09-01

    The generalized Heffron-Phillips model (GHPM) for a microgrid containing a photovoltaic (PV)-diesel machine (DM)-induction motor (IM)-governor (GV) (PDIG) has been developed at the low voltage level. A GHPM is calculated by linearization method about a loading condition. An effective Maximum Power Point Tracking (MPPT) approach for PV network has been done using sliding mode control (SMC) to maximize output power. Additionally, to improve stability of microgrid for more penetration of renewable energy resources with nonlinear load, a complementary stabilizer has been presented. Imperialist competitive algorithm (ICA) is utilized to design of gains for the complementary stabilizer with the multiobjective function. The stability analysis of the PDIG system has been completed with eigenvalues analysis and nonlinear simulations. Robustness and validity of the proposed controllers on damping of electromechanical modes examine through time domain simulation under input mechanical torque disturbances. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  14. Recent Updates to the System Advisor Model (SAM)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DiOrio, Nicholas A

    The System Advisor Model (SAM) is a mature suite of techno-economic models for many renewable energy technologies that can be downloaded for free as a desktop application or software development kit. SAM is used for system-level modeling, including generating performance pro the release of the code as an open source project on GitHub. Other additions that will be covered include the ability to download data directly into SAM from the National Solar Radiation Database (NSRDB) and up- dates to a user-interface macro that assists with PV system sizing. A brief update on SAM's battery model and its integration with themore » detailed photovoltaic model will also be discussed. Finally, an outline of planned work for the next year will be presented, including the addition of a bifacial model, support for multiple MPPT inputs for detailed inverter modeling, and the addition of a model for inverter thermal behavior.« less

  15. Power Maximization Control of Variable Speed Wind Generation System Using Permanent Magnet Synchronous Generator

    NASA Astrophysics Data System (ADS)

    Morimoto, Shigeo; Nakamura, Tomohiko; Takeda, Yoji

    This paper proposes the sensorless output power maximization control of the wind generation system. A permanent magnet synchronous generator (PMSG) is used as a variable speed generator in the proposed system. The generator torque is suitably controlled according to the generator speed and thus the power from a wind turbine settles down on the maximum power point by the proposed MPPT control method, where the information of wind velocity is not required. Moreover, the maximum available generated power is obtained by the optimum current vector control. The current vector of PMSG is optimally controlled according to the generator speed and the required torque in order to minimize the losses of PMSG considering the voltage and current constraints. The proposed wind power generation system can be achieved without mechanical sensors such as a wind velocity detector and a position sensor. Several experimental results show the effectiveness of the proposed control method.

  16. Maximum Power Point tracking charge controllers for telecom applications -- Analysis and economics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wills, R.H.

    Simple charge controllers connect photovoltaic modules directly to the battery bank resulting in a significant power loss if the battery bank voltage differs greatly from the PV Maximum Power Point (MPP) voltage. Recent modeling work at AES has shown that dc-dc converter type MPP tracking charge controllers can deliver more than 30% more energy from PV modules to the battery when the PV modules are cool and the battery state of charge is low--this is typically both the worst case condition (i.e., winter) and also the design condition that determines the PV array size. Economic modeling, based on typical telecommore » system installed costs shows benefits of more than $3/Wp for MPPT over conventional charge controllers in this application--a value that greatly exceeds the additional cost of the dc-dc converter.« less

  17. Design of a nonlinear backstepping control strategy of grid interconnected wind power system based PMSG

    NASA Astrophysics Data System (ADS)

    Errami, Y.; Obbadi, A.; Sahnoun, S.; Benhmida, M.; Ouassaid, M.; Maaroufi, M.

    2016-07-01

    This paper presents nonlinear backstepping control for Wind Power Generation System (WPGS) based Permanent Magnet Synchronous Generator (PMSG) and connected to utility grid. The block diagram of the WPGS with PMSG and the grid side back-to-back converter is established with the dq frame of axes. This control scheme emphasises the regulation of the dc-link voltage and the control of the power factor at changing wind speed. Besides, in the proposed control strategy of WPGS, Maximum Power Point Tracking (MPPT) technique and pitch control are provided. The stability of the regulators is assured by employing Lyapunov analysis. The proposed control strategy for the system has been validated by MATLAB simulations under varying wind velocity and the grid fault condition. In addition, a comparison of simulation results based on the proposed Backstepping strategy and conventional Vector Control is provided.

  18. System frequency support of permanent magnet synchronous generator-based wind power plant

    NASA Astrophysics Data System (ADS)

    Wu, Ziping

    With ever-increasing penetration of wind power into modern electric grids all over the world, a trending replacement of conventional synchronous generators by large wind power plants will likely result in the poor overall frequency regulation performance. On the other hand, permanent magnet synchronous generator wind Turbine System (PMSG-WTG) with full power back to back converters tends to become one of the most promising wind turbine technologies thanks to various advantages. It possesses a significant amount of kinetic energy stored in the rotating mass of turbine blades, which can be utilized to enhance the total inertia of power system. Additionally, the deloaded operation and decoupled control of active and reactive power make it possible for PMSG-WTG to provide a fast frequency regulation through full-power converter. First of all, a comprehensive and in-depth survey is conducted to analyze the motivations for incorporating the inertial response and frequency regulation of VSWT into the system frequency regulation. Besides, control classifications, fundamental control concepts and advanced control schemes implemented for auxiliary frequency support of individual WT or wind power plant are elaborated along with a comparison of the potential frequency regulation capabilities of four major types of WTs. Secondly, a Controls Advanced Research Turbine2-Permanent Magnet Synchronous Generator wind turbine (CART2-PMSG) integrated model representing the typical configuration and operation characteristics of PMSG-WT is established in Matlab/Simulink,. Meanwhile, two different rotor-side converter control schemes, including rotor speed-based control and active power-based control, are integrated into this CART2-PMSG integrated model to perform Maximum Power Point Tracking (MPPT) operation over a wide range of wind speeds, respectively. Thirdly, a novel comprehensive frequency regulation (CFR) control scheme is developed and implemented into the CART2-PMSG model based on rotor speed control. The proposed control scheme is achieved through the coordinated control between rotor speed and modified pitch angle in accordance with different specified wind speed modes. Fourth, an improved inertial control method based on the maximum power point tracking operation curve is introduced to boost the overall frequency support capability of PMSG-WTGs based on rotor speed control. Fifth, a novel control method based on the torque limit (TLC) is proposed for the purpose of maximizing the wind turbine (WT)'s inertial response. To avoid the SFD caused by the deloaded operation of WT, a small-scale battery energy storage system (BESS) model is established and implemented to eliminate this impact and meanwhile assist the restoration of wind turbine to MPPT mode by means of coordinated control strategy between BESS and PMSG-WTG. Last but not the least, all three types of control strategies are implemented in the CART2-PMSG integrated model based on rotor speed control or active power control respectively to evaluate their impacts on the wind turbine's structural loads during the frequency regulation process. Simulation results demonstrate that all the proposed methods can enhance the overall frequency regulation performance while imposing very slight negative impact on the major mechanical components of the wind turbine.

  19. ExoMars Mission 2016, Orbiter Module Power System Architecture (Based On An Unregulated Bus & MPPT Controlled Step-Down Voltage Regulators)

    NASA Astrophysics Data System (ADS)

    Digoin, JJ.; Boutelet, E.

    2011-10-01

    The main objective of the ExoMars program is to demonstrate key flight in situ enabling technologies in support of the European ambitions for future exploration missions and to pursue fundamental scientific investigations. Two missions are foreseen within the ExoMars program for the 2016 and 2018 launch opportunities to Mars. The 2016 mission is an ESA led mission that will supply a Mars Orbiter Module (OM) carrying an Entry Descent module (EDM) and NASA/ESA scientific instruments. The 2018 mission is a NASA led mission bringing one ESA rover and one NASA rover onto the Mars surface. This paper presents the OM Electrical Power Sub- system (EPS) design achieved at the end of pre- development phase. The main aspects addressed are: - EPS major constraints due to mission and environment, a succinct description of the power units, - Trade-off analyses results leading to the selected EPS architecture, - Preliminary results of electrical and energy simulations, - EPS units development plan.

  20. A grid-connected single-phase photovoltaic micro inverter

    NASA Astrophysics Data System (ADS)

    Wen, X. Y.; Lin, P. J.; Chen, Z. C.; Wu, L. J.; Cheng, S. Y.

    2017-11-01

    In this paper, the topology of a single-phase grid-connected photovoltaic (PV) micro-inverter is proposed. The PV micro-inverter consists of DC-DC stage with high voltage gain boost and DC-AC conversion stage. In the first stage, we apply the active clamp circuit and two voltage multipliers to achieve soft switching technology and high voltage gain. In addition, the flower pollination algorithm (FPA) is employed for the maximum power point tracking (MPPT) in the PV module in this stage. The second stage cascades a H-bridge inverter and LCL filter. To feed high quality sinusoidal power into the grid, the software phase lock, outer voltage loop and inner current loop control method are adopted as the control strategy. The performance of the proposed topology is tested by Matlab/Simulink. A PV module with maximum power 300W and maximum power point voltage 40V is applied as the input source. The simulation results indicate that the proposed topology and the control strategy are feasible.

  1. Energy optimization for a wind DFIG with flywheel energy storage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hamzaoui, Ihssen, E-mail: hamzaoui-ihssen2000@yahoo.fr; Laboratory of Instrumentation, Faculty of Electronics and Computer, University of Khemis Miliana, Ain Defla; Bouchafaa, Farid, E-mail: fbouchafa@gmail.com

    2016-07-25

    The type of distributed generation unit that is the subject of this paper relates to renewable energy sources, especially wind power. The wind generator used is based on a double fed induction Generator (DFIG). The stator of the DFIG is connected directly to the network and the rotor is connected to the network through the power converter with three levels. The objective of this work is to study the association a Flywheel Energy Storage System (FESS) in wind generator. This system is used to improve the quality of electricity provided by wind generator. It is composed of a flywheel; anmore » induction machine (IM) and a power electronic converter. A maximum power tracking technique « Maximum Power Point Tracking » (MPPT) and a strategy for controlling the pitch angle is presented. The model of the complete system is developed in Matlab/Simulink environment / to analyze the results from simulation the integration of wind chain to networks.« less

  2. Three-phase multilevel solar inverter for motor drive system

    NASA Astrophysics Data System (ADS)

    Bhasagare, Mayuresh P.

    This thesis deals with three phase inverters and the different control strategies that can be associated with an inverter being used together. The first part of this thesis discusses the present research in the fields of PV panels, motor drive systems and three phase inverters along with their control. This control includes various strategies like MPPT, Volts-Hertz and modulation index compensation. Incorporating these techniques together is the goal of this thesis. A new topology for operating an open end motor drive system has also been discusses, where a boost converter and a flyback converter have been used in cascade to run a three phase motor. The main advantage of this is increasing the number of levels and improving the quality of the output voltage, not to mention a few other benefits of having the proposed circuit. A new algorithm has also been designed for starting and stopping the motor, which controls the current drawn from the power source during starting.

  3. Modeling and simulation performance of photovoltaic system integration battery and supercapacitor paralellization of MPPT prototipe for solar vehicle

    NASA Astrophysics Data System (ADS)

    Ajiatmo, Dwi; Robandi, Imam

    2017-03-01

    This paper proposes a control scheme photovoltaic, battery and super capacitor connected in parallel for use in a solar vehicle. Based on the features of battery charging, the control scheme consists of three modes, namely, mode dynamic irradian, constant load mode and constant voltage charging mode. The shift of the three modes can be realized by controlling the duty cycle of the mosffet Boost converter system. Meanwhile, the high voltage which is more suitable for the application can be obtained. Compared with normal charging method with parallel connected current limiting detention and charging method with dynamic irradian mode, constant load mode and constant voltage charging mode, the control scheme is proposed to shorten the charging time and increase the use of power generated from the PV array. From the simulation results and analysis conducted to determine the performance of the system in state transient and steady-state by using simulation software Matlab / Simulink. Response simulation results demonstrate the suitability of the proposed concept.

  4. DISTINCT: Diversity in Solar Talent Through INnovative Curriculum and Training: An Integrated Research and Education Approach towards Creating Diversity and Advancing Utility-Scale Solar Technology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krishnaswami, Hariharan

    The DISTINCT project research objective is to develop an innovative N-port power converter for a utility-scale PV system that is modular, compact and cost-effective and that will enable the integration of a high-frequency, high-voltage solid-state transformer. The novelty of the proposed research is the electrical power conversion architecture using an N-port converter system that replaces the output 60Hz transformer with an integrated high-frequency low-weight solid-state transformer reducing power electronics and BOS costs to meet SunShot goals through modularity and direct high-voltage interconnection. A challenge in direct integration with a 13.8kV line is the high voltage handling capacity of the convertersmore » combined with high efficiency operation. The front-end converter for each port is a Neutral-Point Clamped (NPC) Multi-Level dc-dc Dual-Active Bridge (ML-DAB) which allows Maximum Power Point Tracking (MPPT). The integrated high frequency transformer provides the galvanic isolation between the PV and grid side and also steps up the low dc voltage from PV source. Following the ML-DAB stage, in each port, is an inverter with H-bridge configuration or NPC configuration. N number of NPC inverters’ outputs are cascaded to attain the per-phase line-to-neutral voltage to connect directly to the distribution grid (i.e. 13.8 kV). The cascaded inverters have the inherent advantage of using lower rated devices, smaller filters and low Total Harmonic Distortion (THD) required for PV grid interconnection. Our analysis and simulation results show improved performance on cost, efficiency, service life with zero downtime and THD. A comprehensive control scheme is presented to ensure the maximum power from each port and each phase are sent to the grid. A functional prototype of a 2-port converter with ML-DAB and cascaded H-bridges has been designed, built, and tested in a laboratory setup to verify the target technical metrics. The N-port converter system due to its modular structure with individual control per port can be easily adapted to integrate functionalities that go well beyond the conventional grid support functions and mitigates impacts of forecasted fast ramp downs or ramp ups and single-fault conditions by automatic reconfiguration of the output.« less

  5. Amelioration de la qualite d'energie d'un systeme de conversion d'energie eolienne a base de machine asynchrone a double alimentation et connecte au reseau electrique =

    NASA Astrophysics Data System (ADS)

    Abderrahim, Iheb

    Wind power generation has grown strongly in the last decade. This results in the development of Wind Energy Conversion System WECS at the levels of modeling and electrical control. Modern WECS operate at varying wind speeds and are equipped with synchronous and asynchronous generators. Among these generators, the Doubly-Fed Induction Generator (DFIG) offers several advantages and capabilities of active and reactive power in four quadrants. WECS based DFIG also causes less conversion costs and minimum energy losses compared with a WECS based on a synchronous generator powered entirely by full scale of power converters. The connection of such a system to the electrical distribution network involves bidirectional operation of networks. This is clearly established in sub and super synchronous operating modes of DFIG. The grid provides the active power to the rotor of DFIG in sub synchronous operating mode and receives the active power of the rotor in super synchronous operating mode of DFIG. Energy quality is thus of major importance during the integration of wind power to the grid. Poor wave quality can affect network stability and could even cause major problems and consequences. This is even more critical where non-linear loads such as the switching power supplies and variable speed drives, are connected to the grid. The idea of this research work is how to mitigate the problems associated with the wave quality while ensuring better implementation of DFIG so that the whole of WECS remains insensitive to external disturbances and parametric variations. The Grid Side Converter (GSC) must be able to compensate harmonics, current unbalance and reactive power injected by a nonlinear three-phase unbalanced load connected to the grid. In addition to these innovative features to improve the conditions of operation of the grid, it provides also the power flow during different modes of operation of the DFIG. It is considered a simple, efficient and cost competitive solution by saving the use of other power equipment. At the same time, the energy efficiency of wind power conversion chain should be improved by extracting the MPPT. Searching allows us to select vector control and control in synchronous reference to achieve these objectives. WECS based DFIG is simulated in MATLAB SIMULINK in the presence of a non-linear balanced and unbalanced three-phase load.

  6. Analysis of High Switching Frequency Quasi-Z-Source Photovoltaic Inverter Using Wide Bandgap Devices

    NASA Astrophysics Data System (ADS)

    Kayiranga, Thierry

    Power inverters continue to play a key role in todays electrical system more than ever. Power inverters employ power semiconductors to converter direct current (DC) into alternating current (AC). The performance of the semiconductors is based on speed and efficiency. Until recently, Silicon (Si) semiconductors had been established as mature. However, the continuous optimization and improvements in the production process of Si to meet today technology requirements have pushed Si materials to their theoretical limits. In an effort to find a suitable replacement, wide bandgap devices mainly Gallium Nitride (GaN) and Silicon Carbide (SiC), have proved to be excellent candidates offering high operation temperature, high blocking voltage and high switching frequency; of which the latter makes GaN a better candidate in high switching low voltage in Distributed Generations (DG). The single stage Quasi-Z-Source Inverter (qZSI) is also able to draw continuous and constant current from the source making ideal for PV applications in addition to allowing shoot-through states. The qZSI find best applications in medium level ranges where multiples qZS inverters can be cascaded (qZS-CMI) by combining the benefit of the qZSI, boost capabilities and continuous and constant input current, and those of the CMI, low output harmonic content and independent MPPT. When used with GaN devices operating at very high frequency, the qZS network impedance can be significantly reduced. However, the impedance network becomes asymmetric. The asymmetric impedance network (AIN-qZSI) has several advantages such as increased power density, increases system lifetime, small size volume and size making it more attractive for module integrated converter (MIC) concepts. However, there are technical challenges. With asymmetric component, resonance is introduced in the system leading to more losses and audible noise. With small inductances, new operation states become available further increasing the system complexity. This report investigates the AIN-qZSI and present solutions to aforementioned issues.

  7. Fuzzy Logic Controlled Solar Module for Driving Three- Phase Induction Motor

    NASA Astrophysics Data System (ADS)

    Afiqah Zainal, Nurul; Sooi Tat, Chan; Ajisman

    2016-02-01

    Renewable energy produced by solar module gives advantages for generated three- phase induction motor in remote area. But, solar module's ou tput is uncertain and complex. Fuzzy logic controller is one of controllers that can handle non-linear system and maximum power of solar module. Fuzzy logic controller used for Maximum Power Point Tracking (MPPT) technique to control Pulse-Width Modulation (PWM) for switching power electronics circuit. DC-DC boost converter used to boost up photovoltaic voltage to desired output and supply voltage source inverter which controlled by three-phase PWM generated by microcontroller. IGBT switched Voltage source inverter (VSI) produced alternating current (AC) voltage from direct current (DC) source to control speed of three-phase induction motor from boost converter output. Results showed that, the output power of solar module is optimized and controlled by using fuzzy logic controller. Besides that, the three-phase induction motor can be drive and control using VSI switching by the PWM signal generated by the fuzzy logic controller. This concluded that the non-linear system can be controlled and used in driving three-phase induction motor.

  8. Influence of the external and internal parameters on the characteristics of generator PV

    NASA Astrophysics Data System (ADS)

    Zouli, Mounir; Ghoudelbourk, Sihem; Ouari, Ahmed; Dib, Djallel

    2017-02-01

    The growing demand for electric power and inevitable future depletion of conventional sources require major research on the alternative sources, like renewable energies. Among which, solar energy is the most largely used because of its many applications. And as Algeria comprises an exceptional solar layer thanks to its large surfaces, therefore it represents an important source of photovoltaic energy. The objective of this work is to be ensured that the energy produced by the photovoltaic plant supplies the electrical distribution network. The configuration of this system comprises a photovoltaic generator, connected to a chopper booster. For an optimal operation of the system, one must connect in cascades partial generators each one connected to a chopper booster adapted by an order MPPT by the method of Disturbance and Observation (P&O) to ensure the operation of their maximum powers whatever the climatic conditions, and also allows to raise the output voltage of these photovoltaic generators. The adaptation between the photovoltaic generator and the load was carried out with the help of converter DC/DC.

  9. Modified Perfect Harmonics Cancellation Control of a Grid Interfaced SPV Power Generation

    NASA Astrophysics Data System (ADS)

    Singh, B.; Shahani, D. T.; Verma, A. K.

    2015-03-01

    This paper deals with a grid interfaced solar photo voltaic (SPV) power generating system with modified perfect harmonic cancellation (MPHC) control for power quality improvement in terms of mitigation of the current harmonics, power factor correction, control of point of common coupling (PCC) voltage with reactive power compensation and load balancing in a three phase distribution system. The proposed grid interfaced SPV system consists of a SPV array, a dc-dc boost converter and a voltage source converter (VSC) used for the compensation of other connected linear and nonlinear loads at PCC. The reference grid currents are estimated using MPHC method and control signals are derived by using pulse width modulation (PWM) current controller of VSC. The SPV power is fed to the common dc bus of VSC and dc-dc boost converter using maximum power point tracking (MPPT). The dc link voltage of VSC is regulated by using dc voltage proportional integral (PI) controller. The analysis of the proposed SPV power generating system is carried out under dc/ac short circuit and severe SPV-SX and SPV-TX intrusion.

  10. A Lyapunov based approach to energy maximization in renewable energy technologies

    NASA Astrophysics Data System (ADS)

    Iyasere, Erhun

    This dissertation describes the design and implementation of Lyapunov-based control strategies for the maximization of the power captured by renewable energy harnessing technologies such as (i) a variable speed, variable pitch wind turbine, (ii) a variable speed wind turbine coupled to a doubly fed induction generator, and (iii) a solar power generating system charging a constant voltage battery. First, a torque control strategy is presented to maximize wind energy captured in variable speed, variable pitch wind turbines at low to medium wind speeds. The proposed strategy applies control torque to the wind turbine pitch and rotor subsystems to simultaneously control the blade pitch and tip speed ratio, via the rotor angular speed, to an optimum point at which the capture efficiency is maximum. The control method allows for aerodynamic rotor power maximization without exact knowledge of the wind turbine model. A series of numerical results show that the wind turbine can be controlled to achieve maximum energy capture. Next, a control strategy is proposed to maximize the wind energy captured in a variable speed wind turbine, with an internal induction generator, at low to medium wind speeds. The proposed strategy controls the tip speed ratio, via the rotor angular speed, to an optimum point at which the efficiency constant (or power coefficient) is maximal for a particular blade pitch angle and wind speed by using the generator rotor voltage as a control input. This control method allows for aerodynamic rotor power maximization without exact wind turbine model knowledge. Representative numerical results demonstrate that the wind turbine can be controlled to achieve near maximum energy capture. Finally, a power system consisting of a photovoltaic (PV) array panel, dc-to-dc switching converter, charging a battery is considered wherein the environmental conditions are time-varying. A backstepping PWM controller is developed to maximize the power of the solar generating system. The controller tracks a desired array voltage, designed online using an incremental conductance extremum-seeking algorithm, by varying the duty cycle of the switching converter. The stability of the control algorithm is demonstrated by means of Lyapunov analysis. Representative numerical results demonstrate that the grid power system can be controlled to track the maximum power point of the photovoltaic array panel in varying atmospheric conditions. Additionally, the performance of the proposed strategy is compared to the typical maximum power point tracking (MPPT) method of perturb and observe (P&O), where the converter dynamics are ignored, and is shown to yield better results.

  11. Development of Deposition and Characterization Systems for Thin Film Solar Cells

    NASA Astrophysics Data System (ADS)

    Cimaroli, Alexander J.

    Photovoltaic (PV) devices are becoming more important due to a number of economic and environmental factors. PV research relies on the ability to quickly fabricate and characterize these devices. While there are a number of deposition methods that are available in a laboratory setting, they are not necessarily able to be scaled to provide high throughput in a commercial setting. A close-space sublimation (CSS) system was developed to provide a means of depositing thin films in a very controlled and scalable manner. Its viability was explored by using it to deposit the absorber layer in Zn3P2 and CdTe solar cell devices. Excellent control over morphology and growth conditions and a high level of repeatability was demonstrated in the study of textured Zn3P2 thin films. However, some limitations imposed by the structure of Zn3P 2-based PV devices showed that CSS may not be the best approach for depositing Zn3P2 thin films. Despite the inability to make Zn3P2 solar cell devices, high efficiency CdTe solar cells were fabricated using CSS. With the introduction of Perovskite-based solar cell devices, the viability of data collected from conventional J-V measurements was questioned due to the J-V hysteresis that Perovskite devices exhibited. New methods of solar cell characterization were developed in order to accurately and quickly assess the performance of hysteretic PV devices. Both J-V measurements and steady-state efficiency measurements are prone to errors due to hysteresis and maximum power point drift. To resolve both of these issues, a maximum power point tracking (MPPT) system was developed with two algorithms: a simple algorithm and a predictive algorithm. The predictive algorithm showed increased resistance to the effects of hysteresis because of its ability to predict the steady-state current after a bias step with a double exponential decay model fit. Some publications have attempted to quantify the degree of J-V hysteresis present in fabricated Perovskite-based devices, but the analysis relied on J-V measurements. The sweep rate, starting bias, illumination time, etc. would affect the value of the calculated degree of hysteresis. A method of using transient photocurrent measurements is presented to accurately quantify the degree of hysteresis for all solar cells: not just Perovskite-based devices. According to this method, almost all solar cell devices exhibit several forms of J-V hysteresis. This method may open new ways of analyzing the defects in fabricated PV devices.

  12. MP Resulting in Autophagic Cell Death of Microglia through Zinc Changes against Spinal Cord Injury

    PubMed Central

    Li, Dingding; Wang, Guannan; Han, Donghe; Bi, Jing; Li, Chenyuan; Wang, Hongyu; Liu, Zhiyuan; Gao, Wei; Gao, Kai; Yao, Tianchen; Wan, Zhanghui; Li, Haihong; Mei, Xifan

    2016-01-01

    Methylprednisolone pulse therapy (MPPT), as a public recognized therapy of spinal cord injury (SCI), is doubted recently, and the exact mechanism of MP on SCI is unclear. This study sought to investigate the exact effect of MP on SCI. We examined the effect of MP in a model of SCI in vivo and an LPS induced model in vitro. We found that administration of MP produced an increase in the Basso, Beattie, and Bresnahan scores and motor neurons counts of injured rats. Besides the number of activated microglia was apparently reduced by MP in vivo, and Beclin-1 dependent autophagic cell death of microglia was induced by MP in LPS induced model. At the same time, MP increases cellular zinc concentration and level of ZIP8, and TPEN could revert effect of MP on autophagic cell death of microglia. Finally, we have found that MP could inhibit NF-κβ in LPS induced model. These results show that the MP could result in autophagic cell death of microglia, which mainly depends on increasing cellular labile zinc, and may be associated with inhibition of NF-κβ, and that MP can produce neuroprotective effect in SCI. PMID:27057544

  13. Power Subsystem In-Flight Behaviour

    NASA Astrophysics Data System (ADS)

    Loche, Didier; Cosculluela, Valerie

    2005-05-01

    A synthesis of the In-flight monitoring of the Electrical Power Subsystem (EPS) behaviour of SPOT family and Mars Express is presented.It covers the solar array and battery performance, their degradation with life compared to the expected one in order to have lessons learned for future designs but also for in-orbit satellites software improvement.The SPOT family (from SPOT1 launched in 1986 up to ENVISAT/SPOT5 launched in 2002) EPS is based on an unregulated bus hard connected to the batteries. The solar array is split in sections, some digital and others PWM controlled in order to provide an accurate battery voltage and current regulation whatever is satellite power need. This regulation is performed by hardware. Mars Express EPS provides a regulated 28V bus. The battery power is managed by Battery Charge & Discharge Regulator (BCDR). The SA power is controlled by a Maximum Power Point Tracker (MPPT) logic. A bad connection between the SA and the Power Conditioning Unit (PCU) has led to a reduction of the power by about 30% and requested a large amount of test and simulations to estimate which power could be made available to the spacecraft and to monitor the actual EPS performance.

  14. Electric motorcycle charging station powered by solar energy

    NASA Astrophysics Data System (ADS)

    Siriwattanapong, Akarawat; Chantharasenawong, Chawin

    2018-01-01

    This research proposes a design and verification of an off-grid photovoltaic system (PVS) for electric motorcycle charging station to be located in King’s Mongkut’s University of Technology Thonburi, Bangkok, Thailand. The system is designed to work independently (off-grid) and it must be able to fully charge the batteries of a typical passenger electric motorcycle every evening. A 1,000W Toyotron electric motorcycle is chosen for this study. It carries five units of 12.8V 20Ah batteries in series; hence its maximum energy requirement per day is 1,200Wh. An assessment of solar irradiation data and the Generation Factor in Bangkok, Thailand suggests that the charging system consists of one 500W PV panel, an MPPT charge controller, 48V 150Ah battery, a 1,000W DC to AC inverter and other safety devices such as fuses and breakers. An experiment is conducted to verify the viability of the off-grid PVS charging station by collecting the total daily energy generation data in the raining season and winter. The data suggests that the designed off-grid solar power charging station for electric motorcycle is able to supply sufficient energy for daily charging requirements.

  15. Control Strategies for the DAB Based PV Interface System

    PubMed Central

    El-Helw, Hadi M.; Al-Hasheem, Mohamed; Marei, Mostafa I.

    2016-01-01

    This paper presents an interface system based on the Dual Active Bridge (DAB) converter for Photovoltaic (PV) arrays. Two control strategies are proposed for the DAB converter to harvest the maximum power from the PV array. The first strategy is based on a simple PI controller to regulate the terminal PV voltage through the phase shift angle of the DAB converter. The Perturb and Observe (P&O) Maximum Power Point Tracking (MPPT) technique is utilized to set the reference of the PV terminal voltage. The second strategy presented in this paper employs the Artificial Neural Network (ANN) to directly set the phase shift angle of the DAB converter that results in harvesting maximum power. This feed-forward strategy overcomes the stability issues of the feedback strategy. The proposed PV interface systems are modeled and simulated using MATLAB/SIMULINK and the EMTDC/PSCAD software packages. The simulation results reveal accurate and fast response of the proposed systems. The dynamic performance of the proposed feed-forward strategy outdoes that of the feedback strategy in terms of accuracy and response time. Moreover, an experimental prototype is built to test and validate the proposed PV interface system. PMID:27560138

  16. Modeling and control of hybrid wind/photovoltaic/fuel cell distributed generation systems

    NASA Astrophysics Data System (ADS)

    Wang, Caisheng

    Due to ever increasing energy consumption, rising public awareness of environmental protection, and steady progress in power deregulation, alternative (i.e., renewable and fuel cell based) distributed generation (DG) systems have attracted increased interest. Wind and photovoltaic (PV) power generation are two of the most promising renewable energy technologies. Fuel cell (FC) systems also show great potential in DG applications of the future due to their fast technology development and many merits they have, such as high efficiency, zero or low emission (of pollutant gases) and flexible modular structure. The modeling and control of a hybrid wind/PV/FC DG system is addressed in this dissertation. Different energy sources in the system are integrated through an AC bus. Dynamic models for the main system components, namely, wind energy conversion system (WECS), PV energy conversion system (PVECS), fuel cell, electrolyzer, power electronic interfacing circuits, battery, hydrogen storage tank, gas compressor and gas pressure regulator, are developed. Two types of fuel cells have been modeled in this dissertation: proton exchange membrane fuel cell (PEMFC) and solid oxide fuel cell (SOFC). Power control of a grid-connected FC system as well as load mitigation control of a stand-alone FC system are investigated. The pitch angle control for WECS, the maximum power point tracking (MPPT) control for PVECS, and the control for electrolyzer and power electronic devices, are also addressed in the dissertation. Based on the dynamic component models, a simulation model for the proposed hybrid energy system has been developed using MATLAB/Simulink. The overall power management strategy for coordinating the power flows among the different energy sources is presented in the dissertation. Simulation studies have been carried out to verify the system performance under different scenarios using a practical load profile and real weather data. The results show that the overall power management strategy is effective and the power flows among the different energy sources and the load demand is balanced successfully. The DG's impacts on the existing power system are also investigated in this dissertation. Analytical methods for finding optimal sites to deploy DG sources in power systems are presented and verified with simulation studies.

  17. The QBito CubeSat: Applications in Space Engineering Education at Technical University of Madrid

    NASA Astrophysics Data System (ADS)

    Fernandez Fraile, Jose Javier; Laverón-Simavilla, Ana; Calvo, Daniel; Moreno Benavides, Efren

    The QBito CubeSat is one of the 50 CubeSats that is being developed for the QB50 project. The project is funded by the 7 (th) Frame Program to launch 50 CubeSats in a ‘string-of-pearls’ configuration for multi-point, in-situ measurements in the lower thermosphere and re-entry research. The 50 CubeSats, developed by an international network of universities and research institutions, will comprise 40 double CubeSats with atmospheric sensors and 10 double or triple CubeSats for science and technology demonstration. It will be the first large-scale CubeSat constellation in orbit; a concept that has been under discussion for several years but not implemented up to now. This project has a high educational interest for universities; beyond the scientific and technological results, being part of an international group of over 90 universities all over the world working and sharing knowledge to achieve a successful mission represents an exciting opportunity. The QBito project main educational motivation is to educate students in space technologies and in space systems engineering. The Universidad Politécnica de Madrid (UPM) is designing, developing, building and testing one of the double CubeSats carrying as payload a kit of atmospheric sensors from the consortium, and other payloads developed by the team such as an IR non-refrigerated sensor, a Phase Change Material (PCM) for thermal control applications, a Fuzzy Logic Attitude Control System and other technological developments such as an optimized antenna deployment mechanism, a lightweight multi-mission configurable structure, and an efficient Electric Power System (EPS) with a Maximum Peak Power Tracker (MPPT). This project has been integrated in the training of the Aerospatiale Engineering, Master and PhD degree students by involving them in the complete engineering process, from its conceptual design to the post-flight conclusions. Three subsystems have been selected for being developed from the conceptual design stage to the flight device: structure, electrical power system and antenna deployment mechanism. In this work, the main characteristics adopted for structure are presented. The project has already provided very interesting lessons to all the people involved, not only students.

  18. Light and Heavy Tactical Wheeled Vehicle Fuel Consumption Evaluations Using Fuel Efficient Gear Oils (FEGO)

    DTIC Science & Technology

    2016-05-01

    UNCLASSIFIED LIGHT AND HEAVY TACTICAL WHEELED VEHICLE FUEL CONSUMPTION EVALUATIONS USING FUEL EFFICIENT GEAR OILS (FEGO) FINAL... HEAVY TACTICAL WHEELED VEHICLE FUEL CONSUMPTION EVALUATIONS USING FUEL EFFICIENT GEAR OILS (FEGO) FINAL REPORT TFLRF No. 477 by Adam C...August 2014 – March 2016 4. TITLE AND SUBTITLE LIGHT AND HEAVY TACTICAL WHEELED VEHICLE FUEL CONSUMPTION EVALUATIONS USING FEUL EFFICIENT GEAR OILS

  19. Evaluation of Thermoelectric Devices by the Slope-Efficiency Method

    DTIC Science & Technology

    2016-09-01

    ARL-TR-7837 ● SEP 2016 US Army Research Laboratory Evaluation of Thermoelectric Devices by the Slope-Efficiency Method by...Evaluation of Thermoelectric Devices by the Slope-Efficiency Method by Patrick J Taylor Sensors and Electron Devices Directorate, ARL Jay R...

  20. UDE-based control of variable-speed wind turbine systems

    NASA Astrophysics Data System (ADS)

    Ren, Beibei; Wang, Yeqin; Zhong, Qing-Chang

    2017-01-01

    In this paper, the control of a PMSG (permanent magnet synchronous generator)-based variable-speed wind turbine system with a back-to-back converter is considered. The uncertainty and disturbance estimator (UDE)-based control approach is applied to the regulation of the DC-link voltage and the control of the RSC (rotor-side converter) and the GSC (grid-side converter). For the rotor-side controller, the UDE-based vector control is developed for the RSC with PMSG control to facilitate the application of the MPPT (maximum power point tracking) algorithm for the maximum wind energy capture. For the grid-side controller, the UDE-based vector control is developed to control the GSC with the power reference generated by a UDE-based DC-link voltage controller. Compared with the conventional vector control, the UDE-based vector control can achieve reliable current decoupling control with fast response. Moreover, the UDE-based DC-link voltage regulation can achieve stable DC-link voltage under model uncertainties and external disturbances, e.g. wind speed variations. The effectiveness of the proposed UDE-based control approach is demonstrated through extensive simulation studies in the presence of coupled dynamics, model uncertainties and external disturbances under varying wind speeds. The UDE-based control is able to generate more energy, e.g. by 5% for the wind profile tested.

  1. The evaluation model of the enterprise energy efficiency based on DPSR.

    PubMed

    Wei, Jin-Yu; Zhao, Xiao-Yu; Sun, Xue-Shan

    2017-05-08

    The reasonable evaluation of the enterprise energy efficiency is an important work in order to reduce the energy consumption. In this paper, an effective energy efficiency evaluation index system is proposed based on DPSR (Driving forces-Pressure-State-Response) with the consideration of the actual situation of enterprises. This index system which covers multi-dimensional indexes of the enterprise energy efficiency can reveal the complete causal chain which includes the "driver forces" and "pressure" of the enterprise energy efficiency "state" caused by the internal and external environment, and the ultimate enterprise energy-saving "response" measures. Furthermore, the ANP (Analytic Network Process) and cloud model are used to calculate the weight of each index and evaluate the energy efficiency level. The analysis of BL Company verifies the feasibility of this index system and also provides an effective way to improve the energy efficiency at last.

  2. EVALUATION OF THE EFFICIENCY OF INDUSTRIAL FLARES: INFLUENCE OF GAS COMPOSITION

    EPA Science Inventory

    The report gives results of a pilot-scale evaluation of the efficiency of industrial flares. The work (1) evaluated the effects of additional gas mixtures on flare stability and efficiency with and without pilot assist and (2) correlated flame stability for the different gas mixt...

  3. Comparative analysis of quantitative efficiency evaluation methods for transportation networks

    PubMed Central

    He, Yuxin; Hong, Jian

    2017-01-01

    An effective evaluation of transportation network efficiency could offer guidance for the optimal control of urban traffic. Based on the introduction and related mathematical analysis of three quantitative evaluation methods for transportation network efficiency, this paper compares the information measured by them, including network structure, traffic demand, travel choice behavior and other factors which affect network efficiency. Accordingly, the applicability of various evaluation methods is discussed. Through analyzing different transportation network examples it is obtained that Q-H method could reflect the influence of network structure, traffic demand and user route choice behavior on transportation network efficiency well. In addition, the transportation network efficiency measured by this method and Braess’s Paradox can be explained with each other, which indicates a better evaluation of the real operation condition of transportation network. Through the analysis of the network efficiency calculated by Q-H method, it can also be drawn that a specific appropriate demand is existed to a given transportation network. Meanwhile, under the fixed demand, both the critical network structure that guarantees the stability and the basic operation of the network and a specific network structure contributing to the largest value of the transportation network efficiency can be identified. PMID:28399165

  4. Comparative analysis of quantitative efficiency evaluation methods for transportation networks.

    PubMed

    He, Yuxin; Qin, Jin; Hong, Jian

    2017-01-01

    An effective evaluation of transportation network efficiency could offer guidance for the optimal control of urban traffic. Based on the introduction and related mathematical analysis of three quantitative evaluation methods for transportation network efficiency, this paper compares the information measured by them, including network structure, traffic demand, travel choice behavior and other factors which affect network efficiency. Accordingly, the applicability of various evaluation methods is discussed. Through analyzing different transportation network examples it is obtained that Q-H method could reflect the influence of network structure, traffic demand and user route choice behavior on transportation network efficiency well. In addition, the transportation network efficiency measured by this method and Braess's Paradox can be explained with each other, which indicates a better evaluation of the real operation condition of transportation network. Through the analysis of the network efficiency calculated by Q-H method, it can also be drawn that a specific appropriate demand is existed to a given transportation network. Meanwhile, under the fixed demand, both the critical network structure that guarantees the stability and the basic operation of the network and a specific network structure contributing to the largest value of the transportation network efficiency can be identified.

  5. Research on efficiency evaluation model of integrated energy system based on hybrid multi-attribute decision-making.

    PubMed

    Li, Yan

    2017-05-25

    The efficiency evaluation model of integrated energy system, involving many influencing factors, and the attribute values are heterogeneous and non-deterministic, usually cannot give specific numerical or accurate probability distribution characteristics, making the final evaluation result deviation. According to the characteristics of the integrated energy system, a hybrid multi-attribute decision-making model is constructed. The evaluation model considers the decision maker's risk preference. In the evaluation of the efficiency of the integrated energy system, the evaluation value of some evaluation indexes is linguistic value, or the evaluation value of the evaluation experts is not consistent. These reasons lead to ambiguity in the decision information, usually in the form of uncertain linguistic values and numerical interval values. In this paper, the risk preference of decision maker is considered when constructing the evaluation model. Interval-valued multiple-attribute decision-making method and fuzzy linguistic multiple-attribute decision-making model are proposed. Finally, the mathematical model of efficiency evaluation of integrated energy system is constructed.

  6. Algorithm for evaluating the effectiveness of a high-rise development project based on current yield

    NASA Astrophysics Data System (ADS)

    Soboleva, Elena

    2018-03-01

    The article is aimed at the issues of operational evaluation of development project efficiency in high-rise construction under the current economic conditions in Russia. The author touches the following issues: problems of implementing development projects, the influence of the operational evaluation quality of high-rise construction projects on general efficiency, assessing the influence of the project's external environment on the effectiveness of project activities under crisis conditions and the quality of project management. The article proposes the algorithm and the methodological approach to the quality management of the developer project efficiency based on operational evaluation of the current yield efficiency. The methodology for calculating the current efficiency of a development project for high-rise construction has been updated.

  7. Review of Evaluation, Measurement and Verification Approaches Used to Estimate the Load Impacts and Effectiveness of Energy Efficiency Programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Messenger, Mike; Bharvirkar, Ranjit; Golemboski, Bill

    Public and private funding for end-use energy efficiency actions is expected to increase significantly in the United States over the next decade. For example, Barbose et al (2009) estimate that spending on ratepayer-funded energy efficiency programs in the U.S. could increase frommore » $3.1 billion in 2008 to $$7.5 and 12.4 billion by 2020 under their medium and high scenarios. This increase in spending could yield annual electric energy savings ranging from 0.58% - 0.93% of total U.S. retail sales in 2020, up from 0.34% of retail sales in 2008. Interest in and support for energy efficiency has broadened among national and state policymakers. Prominent examples include {approx}$$18 billion in new funding for energy efficiency programs (e.g., State Energy Program, Weatherization, and Energy Efficiency and Conservation Block Grants) in the 2009 American Recovery and Reinvestment Act (ARRA). Increased funding for energy efficiency should result in more benefits as well as more scrutiny of these results. As energy efficiency becomes a more prominent component of the U.S. national energy strategy and policies, assessing the effectiveness and energy saving impacts of energy efficiency programs is likely to become increasingly important for policymakers and private and public funders of efficiency actions. Thus, it is critical that evaluation, measurement, and verification (EM&V) is carried out effectively and efficiently, which implies that: (1) Effective program evaluation, measurement, and verification (EM&V) methodologies and tools are available to key stakeholders (e.g., regulatory agencies, program administrators, consumers, and evaluation consultants); and (2) Capacity (people and infrastructure resources) is available to conduct EM&V activities and report results in ways that support program improvement and provide data that reliably compares achieved results against goals and similar programs in other jurisdictions (benchmarking). The National Action Plan for Energy Efficiency (2007) presented commonly used definitions for EM&V in the context of energy efficiency programs: (1) Evaluation (E) - The performance of studies and activities aimed at determining the effects and effectiveness of EE programs; (2) Measurement and Verification (M&V) - Data collection, monitoring, and analysis associated with the calculation of gross energy and demand savings from individual measures, sites or projects. M&V can be a subset of program evaluation; and (3) Evaluation, Measurement, and Verification (EM&V) - This term is frequently seen in evaluation literature. EM&V is a catchall acronym for determining both the effectiveness of program designs and estimates of load impacts at the portfolio, program and project level. This report is a scoping study that assesses current practices and methods in the evaluation, measurement and verification (EM&V) of ratepayer-funded energy efficiency programs, with a focus on methods and practices currently used for determining whether projected (ex-ante) energy and demand savings have been achieved (ex-post). M&V practices for privately-funded energy efficiency projects (e.g., ESCO projects) or programs where the primary focus is greenhouse gas reductions were not part of the scope of this study. We identify and discuss key purposes and uses of current evaluations of end-use energy efficiency programs, methods used to evaluate these programs, processes used to determine those methods; and key issues that need to be addressed now and in the future, based on discussions with regulatory agencies, policymakers, program administrators, and evaluation practitioners in 14 states and national experts in the evaluation field. We also explore how EM&V may evolve in a future in which efficiency funding increases significantly, innovative mechanisms for rewarding program performance are adopted, the role of efficiency in greenhouse gas mitigation is more closely linked, and programs are increasingly funded from multiple sources often with multiple program administrators and intended to meet multiple purposes.« less

  8. Optimization of the Controlled Evaluation of Closed Relational Queries

    NASA Astrophysics Data System (ADS)

    Biskup, Joachim; Lochner, Jan-Hendrik; Sonntag, Sebastian

    For relational databases, controlled query evaluation is an effective inference control mechanism preserving confidentiality regarding a previously declared confidentiality policy. Implementations of controlled query evaluation usually lack efficiency due to costly theorem prover calls. Suitably constrained controlled query evaluation can be implemented efficiently, but is not flexible enough from the perspective of database users and security administrators. In this paper, we propose an optimized framework for controlled query evaluation in relational databases, being efficiently implementable on the one hand and relaxing the constraints of previous approaches on the other hand.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    The report is an overview of electric energy efficiency programs. It takes a concise look at what states are doing to encourage energy efficiency and how it impacts electric utilities. Energy efficiency programs began to be offered by utilities as a response to the energy crises of the 1970s. These regulatory-driven programs peaked in the early-1990s and then tapered off as deregulation took hold. Today, rising electricity prices, environmental concerns, and national security issues have renewed interest in increasing energy efficiency as an alternative to additional supply. In response, new methods for administering, managing, and delivering energy efficiency programs aremore » being implemented. Topics covered in the report include: Analysis of the benefits of energy efficiency and key methods for achieving energy efficiency; evaluation of the business drivers spurring increased energy efficiency; Discussion of the major barriers to expanding energy efficiency programs; evaluation of the economic impacts of energy efficiency; discussion of the history of electric utility energy efficiency efforts; analysis of the impact of energy efficiency on utility profits and methods for protecting profitability; Discussion of non-utility management of energy efficiency programs; evaluation of major methods to spur energy efficiency - systems benefit charges, resource planning, and resource standards; and, analysis of the alternatives for encouraging customer participation in energy efficiency programs.« less

  10. Robust network data envelopment analysis approach to evaluate the efficiency of regional electricity power networks under uncertainty.

    PubMed

    Fathollah Bayati, Mohsen; Sadjadi, Seyed Jafar

    2017-01-01

    In this paper, new Network Data Envelopment Analysis (NDEA) models are developed to evaluate the efficiency of regional electricity power networks. The primary objective of this paper is to consider perturbation in data and develop new NDEA models based on the adaptation of robust optimization methodology. Furthermore, in this paper, the efficiency of the entire networks of electricity power, involving generation, transmission and distribution stages is measured. While DEA has been widely used to evaluate the efficiency of the components of electricity power networks during the past two decades, there is no study to evaluate the efficiency of the electricity power networks as a whole. The proposed models are applied to evaluate the efficiency of 16 regional electricity power networks in Iran and the effect of data uncertainty is also investigated. The results are compared with the traditional network DEA and parametric SFA methods. Validity and verification of the proposed models are also investigated. The preliminary results indicate that the proposed models were more reliable than the traditional Network DEA model.

  11. Robust network data envelopment analysis approach to evaluate the efficiency of regional electricity power networks under uncertainty

    PubMed Central

    Sadjadi, Seyed Jafar

    2017-01-01

    In this paper, new Network Data Envelopment Analysis (NDEA) models are developed to evaluate the efficiency of regional electricity power networks. The primary objective of this paper is to consider perturbation in data and develop new NDEA models based on the adaptation of robust optimization methodology. Furthermore, in this paper, the efficiency of the entire networks of electricity power, involving generation, transmission and distribution stages is measured. While DEA has been widely used to evaluate the efficiency of the components of electricity power networks during the past two decades, there is no study to evaluate the efficiency of the electricity power networks as a whole. The proposed models are applied to evaluate the efficiency of 16 regional electricity power networks in Iran and the effect of data uncertainty is also investigated. The results are compared with the traditional network DEA and parametric SFA methods. Validity and verification of the proposed models are also investigated. The preliminary results indicate that the proposed models were more reliable than the traditional Network DEA model. PMID:28953900

  12. Evaluating the efficiency of a one-square-meter quadrat sampler for riffle-dwelling fish

    USGS Publications Warehouse

    Peterson, J.T.; Rabeni, C.F.

    2001-01-01

    We evaluated the efficacy of a 1-m2 quadrat sampler for collecting riffle-dwelling fishes in an Ozark stream. We used a dual-gear approach to evaluate sampler efficiency in relation to species, fish size, and habitat variables. Quasi-likelihood regression showed sampling efficiency to differ significantly (P 0.05). Sampling efficiency was significantly influenced by physical habitat characteristics. Mean current velocity negatively influenced sampling efficiencies for Cyprinidae (P = 0.009), Cottidae (P = 0.006), and Percidae (P < 0.001), and the amount of cobble substrate negatively influenced sampling efficiencies for Cyprinidae (P = 0.025), Ictaluridae (P < 0.001), and Percidae (P < 0.001). Water temperature negatively influenced sampling efficiency for Cyprinidae (P = 0.009) and Ictaluridae (P = 0.006). Species-richness efficiency was positively influenced (P = 0.002) by percentage of riffle sampled. Under average habitat conditions encountered in stream riffles, the 1-m2 quadrat sampler was most efficient at estimating the densities of Cyprinidae (84%) and Cottidae (80%) and least efficient for Percidae (57%) and Ictaluridae (31%).

  13. Electroluminescence Efficiency Enhancement using Metal Nanoparticles

    DTIC Science & Technology

    2008-06-22

    ABSTRACT We apply the “effective mode volume” theory to evaluate enhancement of the electroluminescence efficiency of semiconductor emitters placed in... Electroluminescence efficiency enhancement using metal nanoparticles J. B. Khurgin,1 G. Sun,2,a and R. A. Soref3 1Department of Electrical and Computer...published online 17 July 2008 We apply the “effective mode volume” theory to evaluate enhancement of the electroluminescence efficiency of semiconductor

  14. A Single-Phase Current Source Solar Inverter with Constant Instantaneous Power, Improved Reliability, and Reduced-Size DC-Link Filter

    NASA Astrophysics Data System (ADS)

    Bush, Craig R.

    This dissertation presents a novel current source converter topology that is primarily intended for single-phase photovoltaic (PV) applications. In comparison with the existing PV inverter technology, the salient features of the proposed topology are: a) the low frequency (double of line frequency) ripple that is common to single-phase inverters is greatly reduced; b) the absence of low frequency ripple enables significantly reduced size pass components to achieve necessary DC-link stiffness and c) improved maximum power point tracking (MPPT) performance is readily achieved due to the tightened current ripple even with reduced-size passive components. The proposed topology does not utilize any electrolytic capacitors. Instead an inductor is used as the DC-link filter and reliable AC film capacitors are utilized for the filter and auxiliary capacitor. The proposed topology has a life expectancy on par with PV panels. The proposed modulation technique can be used for any current source inverter where an unbalanced three-phase operation is desires such as active filters and power controllers. The proposed topology is ready for the next phase of microgrid and power system controllers in that it accepts reactive power commands. This work presents the proposed topology and its working principle supported by with numerical verifications and hardware results. Conclusions and future work are also presented.

  15. A Modular Multilevel Converter with Power Mismatch Control for Grid-Connected Photovoltaic Systems

    DOE PAGES

    Duman, Turgay; Marti, Shilpa; Moonem, M. A.; ...

    2017-05-17

    A modular multilevel power converter configuration for grid connected photovoltaic (PV) systems is proposed. The converter configuration replaces the conventional bulky line frequency transformer with several high frequency transformers, potentially reducing the balance of systems cost of PV systems. The front-end converter for each port is a neutral-point diode clamped (NPC) multi-level dc-dc dual-active bridge (ML-DAB) which allows maximum power point tracking (MPPT). The integrated high frequency transformer provides the galvanic isolation between the PV and grid side and also steps up the low dc voltage from PV source. Following the ML-DAB stage, in each port, is a NPC inverter.more » N number of NPC inverters’ outputs are cascaded to attain the per-phase line-to-neutral voltage to connect directly to the distribution grid (i.e., 13.8 kV). The cascaded NPC (CNPC) inverters have the inherent advantage of using lower rated devices, smaller filters and low total harmonic distortion required for PV grid interconnection. The proposed converter system is modular, scalable, and serviceable with zero downtime with lower foot print and lower overall cost. A novel voltage balance control at each module based on power mismatch among N-ports, have been presented and verified in simulation. Analysis and simulation results are presented for the N-port converter. The converter performance has also been verified on a hardware prototype.« less

  16. A Smart Power Electronic Multiconverter for the Residential Sector.

    PubMed

    Guerrero-Martinez, Miguel Angel; Milanes-Montero, Maria Isabel; Barrero-Gonzalez, Fermin; Miñambres-Marcos, Victor Manuel; Romero-Cadaval, Enrique; Gonzalez-Romera, Eva

    2017-05-26

    The future of the grid includes distributed generation and smart grid technologies. Demand Side Management (DSM) systems will also be essential to achieve a high level of reliability and robustness in power systems. To do that, expanding the Advanced Metering Infrastructure (AMI) and Energy Management Systems (EMS) are necessary. The trend direction is towards the creation of energy resource hubs, such as the smart community concept. This paper presents a smart multiconverter system for residential/housing sector with a Hybrid Energy Storage System (HESS) consisting of supercapacitor and battery, and with local photovoltaic (PV) energy source integration. The device works as a distributed energy unit located in each house of the community, receiving active power set-points provided by a smart community EMS. This central EMS is responsible for managing the active energy flows between the electricity grid, renewable energy sources, storage equipment and loads existing in the community. The proposed multiconverter is responsible for complying with the reference active power set-points with proper power quality; guaranteeing that the local PV modules operate with a Maximum Power Point Tracking (MPPT) algorithm; and extending the lifetime of the battery thanks to a cooperative operation of the HESS. A simulation model has been developed in order to show the detailed operation of the system. Finally, a prototype of the multiconverter platform has been implemented and some experimental tests have been carried out to validate it.

  17. A Modular Multilevel Converter with Power Mismatch Control for Grid-Connected Photovoltaic Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duman, Turgay; Marti, Shilpa; Moonem, M. A.

    A modular multilevel power converter configuration for grid connected photovoltaic (PV) systems is proposed. The converter configuration replaces the conventional bulky line frequency transformer with several high frequency transformers, potentially reducing the balance of systems cost of PV systems. The front-end converter for each port is a neutral-point diode clamped (NPC) multi-level dc-dc dual-active bridge (ML-DAB) which allows maximum power point tracking (MPPT). The integrated high frequency transformer provides the galvanic isolation between the PV and grid side and also steps up the low dc voltage from PV source. Following the ML-DAB stage, in each port, is a NPC inverter.more » N number of NPC inverters’ outputs are cascaded to attain the per-phase line-to-neutral voltage to connect directly to the distribution grid (i.e., 13.8 kV). The cascaded NPC (CNPC) inverters have the inherent advantage of using lower rated devices, smaller filters and low total harmonic distortion required for PV grid interconnection. The proposed converter system is modular, scalable, and serviceable with zero downtime with lower foot print and lower overall cost. A novel voltage balance control at each module based on power mismatch among N-ports, have been presented and verified in simulation. Analysis and simulation results are presented for the N-port converter. The converter performance has also been verified on a hardware prototype.« less

  18. A Long-Distance RF-Powered Sensor Node with Adaptive Power Management for IoT Applications.

    PubMed

    Pizzotti, Matteo; Perilli, Luca; Del Prete, Massimo; Fabbri, Davide; Canegallo, Roberto; Dini, Michele; Masotti, Diego; Costanzo, Alessandra; Franchi Scarselli, Eleonora; Romani, Aldo

    2017-07-28

    We present a self-sustained battery-less multi-sensor platform with RF harvesting capability down to -17 dBm and implementing a standard DASH7 wireless communication interface. The node operates at distances up to 17 m from a 2 W UHF carrier. RF power transfer allows operation when common energy scavenging sources (e.g., sun, heat, etc.) are not available, while the DASH7 communication protocol makes it fully compatible with a standard IoT infrastructure. An optimized energy-harvesting module has been designed, including a rectifying antenna (rectenna) and an integrated nano-power DC/DC converter performing maximum-power-point-tracking (MPPT). A nonlinear/electromagnetic co-design procedure is adopted to design the rectenna, which is optimized to operate at ultra-low power levels. An ultra-low power microcontroller controls on-board sensors and wireless protocol, to adapt the power consumption to the available detected power by changing wake-up policies. As a result, adaptive behavior can be observed in the designed platform, to the extent that the transmission data rate is dynamically determined by RF power. Among the novel features of the system, we highlight the use of nano-power energy harvesting, the implementation of specific hardware/software wake-up policies, optimized algorithms for best sampling rate implementation, and adaptive behavior by the node based on the power received.

  19. A Long-Distance RF-Powered Sensor Node with Adaptive Power Management for IoT Applications

    PubMed Central

    del Prete, Massimo; Fabbri, Davide; Canegallo, Roberto; Dini, Michele; Costanzo, Alessandra

    2017-01-01

    We present a self-sustained battery-less multi-sensor platform with RF harvesting capability down to −17 dBm and implementing a standard DASH7 wireless communication interface. The node operates at distances up to 17 m from a 2 W UHF carrier. RF power transfer allows operation when common energy scavenging sources (e.g., sun, heat, etc.) are not available, while the DASH7 communication protocol makes it fully compatible with a standard IoT infrastructure. An optimized energy-harvesting module has been designed, including a rectifying antenna (rectenna) and an integrated nano-power DC/DC converter performing maximum-power-point-tracking (MPPT). A nonlinear/electromagnetic co-design procedure is adopted to design the rectenna, which is optimized to operate at ultra-low power levels. An ultra-low power microcontroller controls on-board sensors and wireless protocol, to adapt the power consumption to the available detected power by changing wake-up policies. As a result, adaptive behavior can be observed in the designed platform, to the extent that the transmission data rate is dynamically determined by RF power. Among the novel features of the system, we highlight the use of nano-power energy harvesting, the implementation of specific hardware/software wake-up policies, optimized algorithms for best sampling rate implementation, and adaptive behavior by the node based on the power received. PMID:28788084

  20. A Smart Power Electronic Multiconverter for the Residential Sector

    PubMed Central

    Guerrero-Martinez, Miguel Angel; Milanes-Montero, Maria Isabel; Barrero-Gonzalez, Fermin; Miñambres-Marcos, Victor Manuel; Romero-Cadaval, Enrique; Gonzalez-Romera, Eva

    2017-01-01

    The future of the grid includes distributed generation and smart grid technologies. Demand Side Management (DSM) systems will also be essential to achieve a high level of reliability and robustness in power systems. To do that, expanding the Advanced Metering Infrastructure (AMI) and Energy Management Systems (EMS) are necessary. The trend direction is towards the creation of energy resource hubs, such as the smart community concept. This paper presents a smart multiconverter system for residential/housing sector with a Hybrid Energy Storage System (HESS) consisting of supercapacitor and battery, and with local photovoltaic (PV) energy source integration. The device works as a distributed energy unit located in each house of the community, receiving active power set-points provided by a smart community EMS. This central EMS is responsible for managing the active energy flows between the electricity grid, renewable energy sources, storage equipment and loads existing in the community. The proposed multiconverter is responsible for complying with the reference active power set-points with proper power quality; guaranteeing that the local PV modules operate with a Maximum Power Point Tracking (MPPT) algorithm; and extending the lifetime of the battery thanks to a cooperative operation of the HESS. A simulation model has been developed in order to show the detailed operation of the system. Finally, a prototype of the multiconverter platform has been implemented and some experimental tests have been carried out to validate it. PMID:28587131

  1. Evaluation of railway transportation efficiency based on super-cross efficiency

    NASA Astrophysics Data System (ADS)

    Kuang, Xiuyuan

    2018-01-01

    The efficiency of railway transportation is an important index. It can measure the development of railway transportation enterprises, and the efficiency of railway transportation has become a hot issue in the study of railway development. Data envelopment analysis (DEA) has been widely applied to railway efficiency analysis. In this paper, BBC model and super-cross efficiency model are constructed by using DEA theory, taking the 18 Railway Bureau as the research object, with the mileage, the number of employees, locomotive number, average daily loading number as input indicators, the passenger turnover, freight turnover and transport income as output indicators, then calculated and evaluated comprehensive efficiency, pure technical efficiency and scale efficiency. We get that the super-cross efficiency is more in line with the actual situation. Getting the super-cross efficiency is more in line with the actual situation.

  2. Evaluation of input output efficiency of oil field considering undesirable output —A case study of sandstone reservoir in Xinjiang oilfield

    NASA Astrophysics Data System (ADS)

    Zhang, Shuying; Wu, Xuquan; Li, Deshan; Xu, Yadong; Song, Shulin

    2017-06-01

    Based on the input and output data of sandstone reservoir in Xinjiang oilfield, the SBM-Undesirable model is used to study the technical efficiency of each block. Results show that: the model of SBM-undesirable to evaluate its efficiency and to avoid defects caused by traditional DEA model radial angle, improve the accuracy of the efficiency evaluation. by analyzing the projection of the oil blocks, we find that each block is in the negative external effects of input redundancy and output deficiency benefit and undesirable output, and there are greater differences in the production efficiency of each block; the way to improve the input-output efficiency of oilfield is to optimize the allocation of resources, reduce the undesirable output and increase the expected output.

  3. Efficient evaluation of the Coulomb force in the Gaussian and finite-element Coulomb method.

    PubMed

    Kurashige, Yuki; Nakajima, Takahito; Sato, Takeshi; Hirao, Kimihiko

    2010-06-28

    We propose an efficient method for evaluating the Coulomb force in the Gaussian and finite-element Coulomb (GFC) method, which is a linear-scaling approach for evaluating the Coulomb matrix and energy in large molecular systems. The efficient evaluation of the analytical gradient in the GFC is not straightforward as well as the evaluation of the energy because the SCF procedure with the Coulomb matrix does not give a variational solution for the Coulomb energy. Thus, an efficient approximate method is alternatively proposed, in which the Coulomb potential is expanded in the Gaussian and finite-element auxiliary functions as done in the GFC. To minimize the error in the gradient not just in the energy, the derived functions of the original auxiliary functions of the GFC are used additionally for the evaluation of the Coulomb gradient. In fact, the use of the derived functions significantly improves the accuracy of this approach. Although these additional auxiliary functions enlarge the size of the discretized Poisson equation and thereby increase the computational cost, it maintains the near linear scaling as the GFC and does not affects the overall efficiency of the GFC approach.

  4. Evaluating the efficiency of a zakat institution over a period of time using data envelopment analysis

    NASA Astrophysics Data System (ADS)

    Krishnan, Anath Rau; Hamzah, Ahmad Aizuddin

    2017-08-01

    It is crucial for a zakat institution to evaluate and understand how efficiently they have operated in the past, thus ideal strategies could be developed for future improvement. However, evaluating the efficiency of a zakat institution is actually a challenging process as it involves the presence of multiple inputs or/and outputs. This paper proposes a step-by-step procedure comprising two data envelopment analysis models, namely dual Charnes-Cooper-Rhodes and slack-based model to quantitatively measure the overall efficiency of a zakat institution over a period of time. The applicability of the proposed procedure was demonstrated by evaluating the efficiency of Pusat Zakat Sabah, Malaysia from the year of 2007 up to 2015 by treating each year as a decision making unit. Two inputs (i.e. number of staff and number of branches) and two outputs (i.e. total collection and total distribution) were used to measure the overall efficiency achieved each year. The causes of inefficiency and strategy for future improvement were discussed based on the results.

  5. Evaluating Technical Efficiency of Nursing Care Using Data Envelopment Analysis and Multilevel Modeling.

    PubMed

    Min, Ari; Park, Chang Gi; Scott, Linda D

    2016-05-23

    Data envelopment analysis (DEA) is an advantageous non-parametric technique for evaluating relative efficiency of performance. This article describes use of DEA to estimate technical efficiency of nursing care and demonstrates the benefits of using multilevel modeling to identify characteristics of efficient facilities in the second stage of analysis. Data were drawn from LTCFocUS.org, a secondary database including nursing home data from the Online Survey Certification and Reporting System and Minimum Data Set. In this example, 2,267 non-hospital-based nursing homes were evaluated. Use of DEA with nurse staffing levels as inputs and quality of care as outputs allowed estimation of the relative technical efficiency of nursing care in these facilities. In the second stage, multilevel modeling was applied to identify organizational factors contributing to technical efficiency. Use of multilevel modeling avoided biased estimation of findings for nested data and provided comprehensive information on differences in technical efficiency among counties and states. © The Author(s) 2016.

  6. Chapter 13: Assessing Persistence and Other Evaluation Issues Cross-Cutting Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurnik, Charles W; Violette, Daniel M.

    Addressing other evaluation issues that have been raised in the context of energy efficiency programs, this chapter focuses on methods used to address the persistence of energy savings, which is an important input to the benefit/cost analysis of energy efficiency programs and portfolios. In addition to discussing 'persistence' (which refers to the stream of benefits over time from an energy efficiency measure or program), this chapter provides a summary treatment of these issues -Synergies across programs -Rebound -Dual baselines -Errors in variables (the measurement and/or accuracy of input variables to the evaluation).

  7. Method for assessing in-service motor efficiency and in-service motor/load efficiency

    DOEpatents

    Kueck, John D.; Otaduy, Pedro J.

    1997-01-01

    A method and apparatus for assessing the efficiency of an in-service motor. The operating characteristics of the in-service motor are remotely measured. The operating characteristics are then applied to an equivalent circuit for electrical motors. Finally the equivalent circuit is evaluated to determine the performance characteristics of said in-service motor. Based upon the evaluation an individual is able to determine the rotor speed, power output, efficiency, and toque of the in-service motor. Additionally, an individual is able to confirm the calculations by comparing measured values with values obtained as a result of the motor equivalent circuit evaluation.

  8. [Evaluation of the efficiency of preventive medical examinations of railway transport workers].

    PubMed

    Pankova, V B; Golysheva, G V; Khvastunov, R M; Makarov, A A

    2006-01-01

    The paper reflects the priority role of preliminary and periodic medical examinations in the system of measures implemented by therapeutic-and-prophylactic institutions of the Ministry of Railway of Russia. It gives a comprehensive assessment of the medical, social, and economic aspects of the efficiency of preventive medical examinations. Emphasis is laid on the necessity of elaborating methods to evaluate the economic efficiency of medical measures under the conditions of market economy. At the same time, light is shed on the difficulties available when a full-scale, within the whole industry, economic evaluation of periodic medical examinations is made. The role of a cost-effect analysis is shown as the most flexible existing principle in the evaluation of the efficiency of medical preventive measures.

  9. Investigation on the Efficiency of Financial Companies in Malaysia with Data Envelopment Analysis Model

    NASA Astrophysics Data System (ADS)

    Weng Siew, Lam; Kah Fai, Liew; Weng Hoe, Lam

    2018-04-01

    Financial ratio and risk are important financial indicators to evaluate the financial performance or efficiency of the companies. Therefore, financial ratio and risk factor are needed to be taken into consideration to evaluate the efficiency of the companies with Data Envelopment Analysis (DEA) model. In DEA model, the efficiency of the company is measured as the ratio of sum-weighted outputs to sum-weighted inputs. The objective of this paper is to propose a DEA model by incorporating the financial ratio and risk factor in evaluating and comparing the efficiency of the financial companies in Malaysia. In this study, the listed financial companies in Malaysia from year 2004 until 2015 are investigated. The results of this study show that AFFIN, ALLIANZ, APEX, BURSA, HLCAP, HLFG, INSAS, LPI, MNRB, OSK, PBBANK, RCECAP and TA are ranked as efficient companies. This implies that these efficient companies have utilized their resources or inputs optimally to generate the maximum outputs. This study is significant because it helps to identify the efficient financial companies as well as determine the optimal input and output weights in maximizing the efficiency of financial companies in Malaysia.

  10. An Evaluation of the Efficiency of Different Hygienisation Methods

    NASA Astrophysics Data System (ADS)

    Zrubková, M.

    2017-10-01

    The aim of this study is to evaluate the efficiency of hygienisation by pasteurisation, temperature-phased anaerobic digestion and sludge liming. A summary of the legislation concerning sludge treatment, disposal and recycling is included. The hygienisation methods are compared not only in terms of hygienisation efficiency but a comparison of other criteria is also included.

  11. Towards a framework for selection of supervisory control for commercial buildings: HVAC system energy efficiency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ramachandran, Thiagarajan; Kundu, Soumya; Chen, Yan

    This paper develops and utilizes an optimization based framework to investigate the maximal energy efficiency potentially attainable by HVAC system operation in a non-predictive context. Performance is evaluated relative to the existing state of the art set point reset strategies. The expected efficiency increase driven by operation constraints relaxations is evaluated.

  12. Towards a framework for selection of supervisory control for commercial buildings: HVAC system energy efficiency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ramachandran, Thiagarajan; Kundu, Soumya; Chen, Yan

    This paper develops and utilizes an optimization based framework to investigate the maximal energy efficiency potentially attainable by HVAC system operation in a non-predictive context. Performance is evaluated relative to the existing state of the art set-point reset strategies. The expected efficiency increase driven by operation constraints relaxations is evaluated.

  13. Potassium Uptake Efficiency and Dynamics in the Rhizosphere of Maize, Wheat, and Sugar Beet Evaluated with a Mechanistic Model

    USDA-ARS?s Scientific Manuscript database

    Plant species differ in nutrient uptake efficiency. With a pot experiment, we evaluated potassium (K) uptake efficiency of maize (Zea mays L.), wheat (Triticum aestivum L.), and sugar beet (Beta vulgaris L.) grown on a low-K soil. Sugar beet and wheat maintained higher shoot K concentrations, indica...

  14. Phytoextraction of arsenic-contaminated soil with Pteris vittata in Henan Province, China: comprehensive evaluation of remediation efficiency correcting for atmospheric depositions.

    PubMed

    Lei, Mei; Wan, Xiaoming; Guo, Guanghui; Yang, Junxing; Chen, Tongbin

    2018-01-01

    Research on the appropriate method for evaluating phytoremediation efficiency is limited. A 2-year field experiment was conducted to investigate phytoremediation efficiency using the hyperaccumulator Pteris vittata on an arsenic (As)-contaminated site. The remediation efficiency was evaluated through the removal rate of As in soils and extraction rate of heavy metals in plants. After 2 years of remediation, the concentration of total As in soils decreased from 16.27 mg kg -1 in 2012 to 14.58 mg kg -1 in 2014. The total remediation efficiency of As was 10.39% in terms of the removal rate of heavy metals calculated for soils, whereas the remediation efficiency calculated from As uptake by P. vittata was 16.09%. Such a discrepancy aroused further consideration on the potential input of As. A large amount of As was brought in by atmospheric emissions, which possibly biased the calculation of remediation efficiency. In fact, considering also the atmospheric depositions of As, the corrected removal rate of As from soil was 16.57%. Therefore, the results of this work suggest that (i) when evaluating the phytoextraction efficiency, the whole input and output cycle of the element of interest in the targeted ecosystem must be considered, and (ii) P. vittata has the potential to be used to remediate As-contaminated soils in Henan Province, China.

  15. EXPERIMENTAL EVALUATION OF FUEL OIL ADDITIVES FOR REDUCING EMISSIONS AND INCREASING EFFICIENCY OF BOILERS

    EPA Science Inventory

    The report gives results of an evaluation of the effectiveness of combustion-type fuel oil additives to reduce emissions and increase efficiency in a 50-bhp (500 kw) commercial oil-fired packaged boiler. Most additive evaluation runs were made during continuous firing, constant-l...

  16. Program Evaluation: Roles and Responsibilities of Boards of Education Relative to Thorough and Efficient Legislation.

    ERIC Educational Resources Information Center

    Research for Better Schools, Inc., Philadelphia, PA.

    The process for providing a "thorough and efficient" (T & E) education according to New Jersey statutes and regulations involves six basic steps. This document suggests procedures for handling the fifth step, educational program evaluation. Processes discussed include committee formation, evaluation planning, action plan…

  17. Research on the technical requirements standards of high efficiency precipitator in power industries for assessment

    NASA Astrophysics Data System (ADS)

    Jin, Huang; Ling, Lin; Jun, Guo; Jianguo, Li; Yongzhong, Wang

    2017-11-01

    Facing the increasingly severe situation of air pollution, China are now positively promoting the evaluation of high efficiency air pollution control equipments and the research of the relative national standards. This paper showed the significance and the effect of formulating the technical requirements of high efficiency precipitator equipments for assessment national standards in power industries as well as the research thoughts and principle of these standards. It introduce the qualitative and quantitative evaluation requirements of high efficiency precipitators using in power industries and the core technical content such as testing, calculating, evaluation methods and so on. The implementation of a series of national standards is in order to lead and promote the production and application of high efficiency precipitator equipments in the field of the prevention of air pollution in national power industries.

  18. Updating the limit efficiency of silicon solar cells

    NASA Technical Reports Server (NTRS)

    Wolf, M.

    1979-01-01

    Evaluation of the limit efficiency based on the simplest, most basic mathematical method that is appropriate for the conditions imposed by the cell model is discussed. The methodology, the solar cell structure, and the selection of the material parameters used in the evaluation are described. The results are discussed including a set of design goals derived from the limit efficiency.

  19. Alternative Methods in the Evaluation of School District Cash Management Programs.

    ERIC Educational Resources Information Center

    Dembowski, Frederick L.

    1980-01-01

    Empirically evaluates three measures of effectiveness of school district cash management: the rate of return method in common use and two new measures--efficiency rating and Net Present Value (NPV). The NPV approach allows examination of efficiency and provides a framework for evaluating other areas of educational policy. (Author/IRT)

  20. A new integrated evaluation method of heavy metals pollution control during melting and sintering of MSWI fly ash.

    PubMed

    Li, Rundong; Li, Yanlong; Yang, Tianhua; Wang, Lei; Wang, Weiyun

    2015-05-30

    Evaluations of technologies for heavy metal control mainly examine the residual and leaching rates of a single heavy metal, such that developed evaluation method have no coordination or uniqueness and are therefore unsuitable for hazard control effect evaluation. An overall pollution toxicity index (OPTI) was established in this paper, based on the developed index, an integrated evaluation method of heavy metal pollution control was established. Application of this method in the melting and sintering of fly ash revealed the following results: The integrated control efficiency of the melting process was higher in all instances than that of the sintering process. The lowest integrated control efficiency of melting was 56.2%, and the highest integrated control efficiency of sintering was 46.6%. Using the same technology, higher integrated control efficiency conditions were all achieved with lower temperatures and shorter times. This study demonstrated the unification and consistency of this method. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. "Efficiency Space" - A Framework for Evaluating Joint Evaporation and Runoff Behavior

    NASA Technical Reports Server (NTRS)

    Koster, Randal

    2014-01-01

    At the land surface, higher soil moisture levels generally lead to both increased evaporation for a given amount of incoming radiation (increased evaporation efficiency) and increased runoff for a given amount of precipitation (increased runoff efficiency). Evaporation efficiency and runoff efficiency can thus be said to vary with each other, motivating the development of a unique hydroclimatic analysis framework. Using a simple water balance model fitted, in different experiments, with a wide variety of functional forms for evaporation and runoff efficiency, we transform net radiation and precipitation fields into fields of streamflow that can be directly evaluated against observations. The optimal combination of the functional forms the combination that produces the most skillful stream-flow simulations provides an indication for how evaporation and runoff efficiencies vary with each other in nature, a relationship that can be said to define the overall character of land surface hydrological processes, at least to first order. The inferred optimal relationship is represented herein as a curve in efficiency space and should be valuable for the evaluation and development of GCM-based land surface models, which by this measure are often found to be suboptimal.

  2. Evaluating the Relationship between Productivity and Quality in Emergency Departments

    PubMed Central

    Bastian, Nathaniel D.; Riordan, John P.

    2017-01-01

    Background In the United States, emergency departments (EDs) are constantly pressured to improve operational efficiency and quality in order to gain financial benefits and maintain a positive reputation. Objectives The first objective is to evaluate how efficiently EDs transform their input resources into quality outputs. The second objective is to investigate the relationship between the efficiency and quality performance of EDs and the factors affecting this relationship. Methods Using two data sources, we develop a data envelopment analysis (DEA) model to evaluate the relative efficiency of EDs. Based on the DEA result, we performed multinomial logistic regression to investigate the relationship between ED efficiency and quality performance. Results The DEA results indicated that the main source of inefficiencies was working hours of technicians. The multinomial logistic regression result indicated that the number of electrocardiograms and X-ray procedures conducted in the ED and the length of stay were significantly associated with the trade-offs between relative efficiency and quality. Structural ED characteristics did not influence the relationship between efficiency and quality. Conclusions Depending on the structural and operational characteristics of EDs, different factors can affect the relationship between efficiency and quality. PMID:29065673

  3. Evaluation of All-Day-Efficiency for selected flat plate and evacuated tube collectors

    NASA Technical Reports Server (NTRS)

    1981-01-01

    An evaluation of all day efficiency for selected flat plate and evacuated tube collectors is presented. Computations are based on a modified version of the NBSIR 78-1305A procedure for all day efficiency. The ASHMET and NOAA data bases for solar insolation are discussed. Details of the algorithm used to convert total (global) horizontal radiation to the collector tilt plane of the selected sites are given along with tables and graphs which show the results of the tests performed during this evaluation.

  4. A study on operation efficiency evaluation based on firm's financial index and benchmark selection: take China Unicom as an example

    NASA Astrophysics Data System (ADS)

    Wu, Zu-guang; Tian, Zhan-jun; Liu, Hui; Huang, Rui; Zhu, Guo-hua

    2009-07-01

    Being the only listed telecom operators of A share market, China Unicom has always been attracted many institutional investors under the concept of 3G recent years,which itself is a great technical progress expectation.Do the institutional investors or the concept of technical progress have signficant effect on the improving of firm's operating efficiency?Though reviewing the documentary about operating efficiency we find that schoolars study this problem useing the regress analyzing based on traditional production function and data envelopment analysis(DEA) and financial index anayzing and marginal function and capital labor ratio coefficient etc. All the methods mainly based on macrodata. This paper we use the micro-data of company to evaluate the operating efficiency.Using factor analyzing based on financial index and comparing the factor score of three years from 2005 to 2007, we find that China Unicom's operating efficiency is under the averge level of benchmark corporates and has't improved under the concept of 3G from 2005 to 2007.In other words,institutional investor or the conception of technical progress expectation have faint effect on the changes of China Unicom's operating efficiency. Selecting benchmark corporates as post to evaluate the operating efficiency is a characteristic of this method ,which is basicallly sipmly and direct.This method is suit for the operation efficiency evaluation of agriculture listed companies because agriculture listed also face technical progress and marketing concept such as tax-free etc.

  5. Finite-size effect on optimal efficiency of heat engines.

    PubMed

    Tajima, Hiroyasu; Hayashi, Masahito

    2017-07-01

    The optimal efficiency of quantum (or classical) heat engines whose heat baths are n-particle systems is given by the strong large deviation. We give the optimal work extraction process as a concrete energy-preserving unitary time evolution among the heat baths and the work storage. We show that our optimal work extraction turns the disordered energy of the heat baths to the ordered energy of the work storage, by evaluating the ratio of the entropy difference to the energy difference in the heat baths and the work storage, respectively. By comparing the statistical mechanical optimal efficiency with the macroscopic thermodynamic bound, we evaluate the accuracy of the macroscopic thermodynamics with finite-size heat baths from the statistical mechanical viewpoint. We also evaluate the quantum coherence effect on the optimal efficiency of the cycle processes without restricting their cycle time by comparing the classical and quantum optimal efficiencies.

  6. Monitoring of energy efficiency of technological modes of gas transport using modern gas-turbine equipment

    NASA Astrophysics Data System (ADS)

    Golik, V. V.; Zemenkova, M. Yu; Shipovalov, A. N.; Akulov, K. A.

    2018-05-01

    The paper presents calculations and an example of energy efficiency justification of the regimes of the equipment used. The engineering design of the gas pipeline in the part of monitoring the energy efficiency of a gas compressor unit (GCU) is considered. The results of the GCU characteristics and its components evaluation are described. The evaluation results of the energy efficiency indicators of the gas pipeline are presented. As an example of the result of the analysis, it is proposed to use gas compressor unit GCU-32 "Ladoga" because of its efficiency and cost effectiveness, in comparison with analogues.

  7. [Correlation of noises in the channels of digital X-ray receiver-transformer and the evaluation of registration's quant efficiency].

    PubMed

    Porosev, V V; Shekhtman, L I; Zelikman, M I; Blinov, N N

    2004-01-01

    Theoretical and experimental research results related with the influence of correlation of signals in neighboring elements of digital X-ray receiver-transformer produced on the evaluation of the output ratio noise/signal and, as a consequence, on the evaluation of quantum registration efficiency are described in the paper.

  8. Efficiency at Faculties of Economics in the Czech Public Higher Education Institutions: Two Different Approaches

    ERIC Educational Resources Information Center

    Flégl, Martin; Vltavská, Kristýna

    2013-01-01

    The paper evaluates research and teaching efficiency at faculties of economics in the public higher education institutions in the Czech Republic. Evaluation is provided in two periods between the years 2006-2010 and 2007-2011. For this evaluation the Data Envelopment Analysis and Index approach are used. Data Envelopment Analysis measures research…

  9. Managing for efficiency in health care: the case of Greek public hospitals.

    PubMed

    Mitropoulos, Panagiotis; Mitropoulos, Ioannis; Sissouras, Aris

    2013-12-01

    This paper evaluates the efficiency of public hospitals with two alternative conceptual models. One model targets resource usage directly to assess production efficiency, while the other model incorporates financial results to assess economic efficiency. Performance analysis of these models was conducted in two stages. In stage one, we utilized data envelopment analysis to obtain the efficiency score of each hospital, while in stage two we took into account the influence of the operational environment on efficiency by regressing those scores on explanatory variables that concern the performance of hospital services. We applied these methods to evaluate 96 general hospitals in the Greek national health system. The results indicate that, although the average efficiency scores in both models have remained relatively stable compared to past assessments, internal changes in hospital performances do exist. This study provides a clear framework for policy implications to increase the overall efficiency of general hospitals.

  10. Magnetic characterization of the stator core of a high-speed motor made of an ultrathin electrical steel sheet using the magnetic property evaluation system

    NASA Astrophysics Data System (ADS)

    Oka, Mohachiro; Enokizono, Masato; Mori, Yuji; Yamazaki, Kazumasa

    2018-04-01

    Recently, the application areas for electric motors have been expanding. For instance, electric motors are used in new technologies such as rovers, drones, cars, and robots. The motor used in such machinery should be small, high-powered, highly-efficient, and high-speed. In such motors, loss at high-speed rotation must be especially minimal. Eddy-current loss in the stator core is known to increase greatly during loss at high-speed rotation of the motor. To produce an efficient high-speed motor, we are developing a stator core for a motor using an ultrathin electrical steel sheet with only a small amount of eddy-current loss. Furthermore, the magnetic property evaluation for efficient, high-speed motor stator cores that use conventional commercial frequency is insufficient. Thus, we made a new high-speed magnetic property evaluation system to evaluate the magnetic properties of the efficient high-speed motor stator core. This system was composed of high-speed A/D converters, D/A converters, and a high-speed power amplifier. In experiments, the ultrathin electrical steel sheet dramatically suppressed iron loss and, in particular, eddy-current loss. In addition, a new high-speed magnetic property evaluation system accurately evaluated the magnetic properties of the efficient high-speed motor stator core.

  11. Vacuum boilers developed heating surfaces technic and economic efficiency evaluation

    NASA Astrophysics Data System (ADS)

    Slobodina, E. N.; Mikhailov, A. G.; Semenov, B. A.

    2018-01-01

    The vacuum boilers as manufacturing proto types application analysis was carried out, the possible directions for the heating surfaces development are identified with a view to improving the energy efficiency. Economic characteristics to evaluate the vacuum boilers application efficiency (Net Discounted Income (NDI), Internal Rate of Return (IRR), Profitability Index (PI) and Payback Period) are represented. The given type boilers application technic and economic efficiency criteria were established. NDI changing curves depending on the finning coefficient and operating pressure were obtained as a result of the conducted calculation studies.

  12. Twisted Savonius turbine based marine current energy conversion system

    NASA Astrophysics Data System (ADS)

    Hassan, Md. Imtiaj

    The Ocean Network Seafloor Instrumentation (ONSFI) Project is a multidisciplinary research and development project that aims to design, fabricate and validate a proof-of-concept seafloor array of wireless marine sensors for use in monitoring seabed processes. The sensor pods, known as Seaformatics, will be powered by ocean bottom currents and will be able to communicate with each other and to the Internet through surface master units to facilitate observation of the ocean floor from the shore. This thesis explores the use of the twisted Savonius turbine as a means of converting the kinetic energy of the free flowing water into electrical energy for the pods. This will eliminate the need for battery replacement. A physical model of the turbine was constructed and tested in the Water Flume at the Marine Institute of Memorial University and in the Wind Tunnel in the Engineering Building at Memorial University. A mathematical model of the turbine was constructed in SolidWorks. This was tested in the Computational Fluid Dynamics or CFD software FLOW-3D. Experimental results were compared with CFD results and the agreement was reasonable. A twisted Savonius turbine emulator was developed to test a dc-dc boost converter. A low cost microcontroller based MPPT algorithm was developed to obtain maximum power from the turbine. Overall the thesis shows that the twisted Savonius turbine can provide the power needed by the sensor pods. It also shows that CFD is a viable way to study the performance of the Savonius type of turbine.

  13. Performance evaluation of nonhomogeneous hospitals: the case of Hong Kong hospitals.

    PubMed

    Li, Yongjun; Lei, Xiyang; Morton, Alec

    2018-02-14

    Throughout the world, hospitals are under increasing pressure to become more efficient. Efficiency analysis tools can play a role in giving policymakers insight into which units are less efficient and why. Many researchers have studied efficiencies of hospitals using data envelopment analysis (DEA) as an efficiency analysis tool. However, in the existing literature on DEA-based performance evaluation, a standard assumption of the constant returns to scale (CRS) or the variable returns to scale (VRS) DEA models is that decision-making units (DMUs) use a similar mix of inputs to produce a similar set of outputs. In fact, hospitals with different primary goals supply different services and provide different outputs. That is, hospitals are nonhomogeneous and the standard assumption of the DEA model is not applicable to the performance evaluation of nonhomogeneous hospitals. This paper considers the nonhomogeneity among hospitals in the performance evaluation and takes hospitals in Hong Kong as a case study. An extension of Cook et al. (2013) [1] based on the VRS assumption is developed to evaluated nonhomogeneous hospitals' efficiencies since inputs of hospitals vary greatly. Following the philosophy of Cook et al. (2013) [1], hospitals are divided into homogeneous groups and the product process of each hospital is divided into subunits. The performance of hospitals is measured on the basis of subunits. The proposed approach can be applied to measure the performance of other nonhomogeneous entities that exhibit variable return to scale.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Knittel, Christopher; Wolfran, Catherine; Gandhi, Raina

    A wide range of climate plans rely on energy efficiency to generate energy and carbon emissions reductions, but conventional wisdom holds that consumers have historically underinvested in energy efficiency upgrades. This underinvestment may occur for a variety of reasons, one of which is that consumers are not adequately informed about the benefits to energy efficiency. To address this, the U.S. Department of Energy created a tool called the Home Energy Score (HEScore) to act as a simple, low-cost means to provide clear information about a home’s energy efficiency and motivate homeowners and homebuyers to invest in energy efficiency. The Departmentmore » of Energy is in the process of conducting four evaluations assessing the impact of the Home Energy Score on residential energy efficiency investments and program participation. This paper describes one of these evaluations: a randomized controlled trial conducted in New Jersey in partnership with New Jersey Natural Gas. The evaluation randomly provides homeowners who have received an audit, either because they have recently replaced their furnace, boiler, and/or gas water heater with a high-efficiency model and participated in a free audit to access an incentive, or because they requested an independent audit3, between May 2014 and October 2015, with the Home Energy Score.« less

  15. Evaluation of the efficiency of heat and moisture exchangers during paediatric anaesthesia.

    PubMed

    Luchetti, M; Pigna, A; Gentili, A; Marraro, G

    1999-01-01

    This study evaluates the efficiency of heat and moisture exchangers (HMEs) in allowing adequate humidification and warming during anaesthesia in children. Eighteen paediatric patients undergoing anaesthesia were divided into two groups: group A ten patients: infants up to 10 kg-->Hygrobaby HME; group B 8 patients: children above 10 kg-->Hygroboy HME. The following parameters were evaluated: body temperature (bT), room temperature (rT), fresh gas temperature, HME warm-up time, inspired and expired gases temperature and humidity, conserving efficiency, and duration of anaesthesia. Gas temperatures were recorded by means of a recorder fitted with four thermal probes. Humidity values were mathematically derived. The correlation between efficiency and rT, bT, and fresh gas temperature was computed. In both groups the inspired gases temperatures were below 30 degrees C. Inspired absolute humidity was never more than 28 mgH2O.l(-1). The conserving efficiency was good (0.93 in both groups). A positive correlation was found between efficiency and fresh gas temperature. HMEs did not meet the minimum standards for humidity and heating during anaesthesia in children, although their conserving efficiency was found to be satisfactory.

  16. Health policy in times of austerity-A conceptual framework for evaluating effects of policy on efficiency and equity illustrated with examples from Europe since 2008.

    PubMed

    Wenzl, Martin; Naci, Huseyin; Mossialos, Elias

    2017-09-01

    The objective of this paper is to provide a framework for evaluation of changes in health policy against overarching health system goals. We propose a categorisation of policies into seven distinct health system domains. We then develop existing analytical concepts of insurance coverage and cost-effectiveness further to evaluate the effects of policies in each domain on equity and efficiency. The framework is illustrated with likely effects of policy changes implemented in a sample of European countries since 2008. Our illustrative analysis suggests that cost containment has been the main focus and that countries have implemented a mix of measures that are efficient or efficiency neutral. Similarly, policies are likely to have mixed effects on equity. Additional user charges were a common theme but these were frequently accompanied by additional exemptions, making their likely effects on equity difficult to evaluate. We provide a framework for future, and more detailed, evaluations of changes in health policy. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  17. Evaluation of Surface Sampling for Bacillus Spores Using ...

    EPA Pesticide Factsheets

    Journal Article In this study, commercially-available domestic cleaning robots were evaluated for spore surface sampling efficiency on common indoor surfaces. The current study determined the sampling efficiency of each robot, without modifying the sensors, algorithms, or logics set by the manufacturers.

  18. Energy-efficiency program for clothes washers, clothes dryers, and dishwashers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1977-11-01

    The objectives of this study of dishwashers, clothes washers, and clothes dryers are: to evaluate existing energy efficiency test procedures and recommend the use of specific test procedures for each appliance group and to establish the maximum economically and technologically feasible energy-efficiency improvement goals for each appliance group. Specifically, the program requirements were to determine the energy efficiency of the 1972 models, to evaluate the feasibility improvements that could be implemented by 1980 to maximize energy efficiency, and to calculate the percentage efficiency improvement based on the 1972 baseline and the recommended 1980 targets. The test program was conducted usingmore » 5 dishwashers, 4 top-loading clothes washers, one front-loading clothes washer, 4 electric clothes dryers, and 4 gas clothes dryers. (MCW)« less

  19. 10 CFR 431.17 - Determination of efficiency.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... state-registered professional engineer, who is qualified to perform an evaluation of electric motor... EQUIPMENT Electric Motors Test Procedures, Materials Incorporated and Methods of Determining Efficiency § 431.17 Determination of efficiency. When a party determines the energy efficiency of an electric motor...

  20. 40 CFR 63.2354 - What performance tests, design evaluations, and performance evaluations must I conduct?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., appendix A, to determine compliance with the organic HAP or TOC emission limit, you may use EPA Method 18... formaldehyde control efficiency as a surrogate for total organic HAP or TOC efficiency, or at the outlet of a...

  1. [sgRNA design for the CRISPR/Cas9 system and evaluation of its off-target effects].

    PubMed

    Xie, Sheng-song; Zhang, Yi; Zhang, Li-sheng; Li, Guang-lei; Zhao, Chang-zhi; Ni, Pan; Zhao, Shu-hong

    2015-11-01

    The third generation of CRISPR/Cas9-mediated genome editing technology has been successfully applied to genome modification of various species including animals, plants and microorganisms. How to improve the efficiency of CRISPR/Cas9 genome editing and reduce its off-target effects has been extensively explored in this field. Using sgRNA (Small guide RNA) with high efficiency and specificity is one of the critical factors for successful genome editing. Several software have been developed for sgRNA design and/or off-target evaluation, which have advantages and disadvantages respectively. In this review, we summarize characters of 16 kinds online and standalone software for sgRNA design and/or off-target evaluation and conduct a comparative analysis of these different kinds of software through developing 38 evaluation indexes. We also summarize 11 experimental approaches for testing genome editing efficiency and off-target effects as well as how to screen highly efficient and specific sgRNA.

  2. In Vitro Comparison of Adipokine Export Signals.

    PubMed

    Sharafi, Parisa; Kocaefe, Y Çetin

    2016-01-01

    Mammalian cells are widely used for recombinant protein production in research and biotechnology. Utilization of export signals significantly facilitates production and purification processes. 35 years after the discovery of the mammalian export machinery, there still are obscurities regarding the efficiency of the export signals. The aim of this study was the comparative evaluation of the efficiency of selected export signals using adipocytes as a cell model. Adipocytes have a large capacity for protein secretion including several enzymes, adipokines, and other signaling molecules, providing a valid system for a quantitative evaluation. Constructs that expressed N-terminal fusion export signals were generated to express Enhanced Green Fluorescence Protein (EGFP) as a reporter for quantitative and qualitative evaluation. Furthermore, fluorescent microscopy was used to trace the intracellular traffic of the reporter. The export efficiency of six selected proteins secreted from adipocytes was evaluated. Quantitative comparison of intracellular and exported fractions of the recombinant constructs demonstrated a similar efficiency among the studied sequences with minor variations. The export signal of Retinol Binding Protein (RBP4) exhibited the highest efficiency. This study presents the first quantitative data showing variations among export signals, in adipocytes which will help optimization of recombinant protein distribution.

  3. [Ideas and methods on efficient screening of traditional medicines for anti-osteoporosis activity based on M-Act/Tox integrated evaluation using zebrafish].

    PubMed

    Wang, Mo; Ling, Jie; Chen, Ying; Song, Jie; Sun, E; Shi, Zi-Qi; Feng, Liang; Jia, Xiao-Bin; Wei, Ying-Jie

    2017-11-01

    The increasingly apparent liver injury problems of bone strengthening Chinese medicines have brought challenges for clinical application, and it is necessary to consider both effectiveness and safety in screening anti-osteoporosis Chinese medicines. Metabolic transformation is closely related to drug efficacy and toxicity, so it is significant to comprehensively consider metabolism-action/toxicity(M-Act/Tox) for screening anti-osteoporosis Chinese medicines. The current evaluation models and the number of compounds(including metabolites) severely restrict efficient screening in vivo. By referring to previous relevant research and domestic and abroad literature, zebrafish M-Act/Tox integrative method was put forward for efficiently screening anti-osteoporosis herb medicines, which has organically integrated zebrafish metabolism model, osteoporosis model and toxicity evaluation method. This method can break through the bottleneck and blind spots that trace compositions can't achieve efficient and integrated in vivo evaluation, and realize both efficient and comprehensive screening on anti-osteoporosis traditional medicines based on in vivo process taking both safety and effectiveness into account, which is significant to accelerate discovery of effective and safe innovative traditional Chinese medicines for osteoporosis. Copyright© by the Chinese Pharmaceutical Association.

  4. The evaluation of basin water resources utilization efficiency based on Chaos projection mode

    NASA Astrophysics Data System (ADS)

    Guan, X.; Liang, S.; Meng, Y.; Wang, H.

    2017-12-01

    To promote the coordinated development of a healthy economy, society, and environment, and the sustainable development of water resources comprehensive utilization efficiency (WRCUE), this study investigated appropriate indicators using the trapezoidal fuzzy number method, and constructed an evaluation index system for WRCUE. A WRCUE evaluation model is applied to the areas in the Yellow River Basin in China using a genetic projection pursuit method. The comprehensive evaluation index system of water use efficiency includes 6 indicators: Water consumption per unit industrial value added, water consumption per unit GDP, eliminate the climate effect on agricultural water use efficiency, irrigation water consumption per unit area, domestic water use per capita and industrial water ratio. Then, multiple indexes in the index system are transformed to a comprehensive index by the combined model, which is used to represent the total water resources utilization efficiency. Results show that the WRCUE in Yellow River basin and the provinces have a great distance. WRCUE is well developed in Shanxi, Shandong, and Henan provinces, moderately developed in Shaanxi, Inner Mongolia, and Sichuan provinces, and poorly developed in the Ningxia Autonomous Region, Gansu Province, and Qinghai Province. According to the capacities of provinces, related measures are proposed.

  5. LyP-1 ultrasonic microbubbles targeting to cancer cell as tumor bio-acoustics markers or drug carriers: targeting efficiency evaluation in, microfluidic channels.

    PubMed

    Li, Xiang; Jin, Qiaofeng; Chen, Tan; Zhang, Baoyue; Zheng, Rongqin; Wang, Zhanhui; Zheng, Hairong

    2009-01-01

    Using ultrasonic contrast microbubbles as acoustic biomarkers and drug carrier vehicles by conjugating tumor specific antibody to microbubbles has shown great potential in ultrasonic tumor molecular imaging or drug-delivery and therapy. Microbubble probe targeting efficiency is one of the major challenges. In this study, we developed a novel method to evaluate the targeting capability and efficiency of microbubbles to cells, and more specifically, microbubbles binding LyP-1 (a cyclic nonapeptide acid peptide) target to cancer cell within a microfluidic system. The micro cell sieves within the microfludic channels could trap the tumor cells and enhance the microbubble's interaction with the cell. Assisted with the controllable fluid shear stress, the microbubble's targeting to the cell and the corresponding affinity efficiency could be quantitatively evaluated under a florescent microscope. The system provides a useful low-cost high efficient in vitro platform for studying microbubble-cell interaction for ultrasonic tumor molecular imaging or drug-delivery and therapy.

  6. Heuristic evaluation of eNote: an electronic notes system.

    PubMed

    Bright, Tiffani J; Bakken, Suzanne; Johnson, Stephen B

    2006-01-01

    eNote is an electronic health record (EHR) system based on semi-structured narrative documents. A heuristic evaluation was conducted with a sample of five usability experts. eNote performed highly in: 1)consistency with standards and 2)recognition rather than recall. eNote needs improvement in: 1)help and documentation, 2)aesthetic and minimalist design, 3)error prevention, 4)helping users recognize, diagnosis, and recover from errors, and 5)flexibility and efficiency of use. The heuristic evaluation was an efficient method of evaluating our interface.

  7. Comparative evaluation of rail and truck fuel efficiency on competitive corridors : final report

    DOT National Transportation Integrated Search

    2009-11-19

    This study provides a comparative evaluation of rail and truck fuel efficiency on corridors and services in which both modes compete. For the purposes of this study, competitive movements are defined as those of the same commodity having the same (or...

  8. FACILITIES EVALUATION OF HIGH EFFICIENCY BOILER DESTRUCTION PCB WASTE

    EPA Science Inventory

    The report gives results of an evaluation of destruction in two different high-efficiency boilers (as an alternative to landfill disposal) of waste (a rendering plant byproduct, yellow grease) found to be contaminated by PCBs from a transformer leak. (The PCB content--under 500 p...

  9. The Improvement of Efficiency in the Numerical Computation of Orbit Trajectories

    NASA Technical Reports Server (NTRS)

    Dyer, J.; Danchick, R.; Pierce, S.; Haney, R.

    1972-01-01

    An analysis, system design, programming, and evaluation of results are described for numerical computation of orbit trajectories. Evaluation of generalized methods, interaction of different formulations for satellite motion, transformation of equations of motion and integrator loads, and development of efficient integrators are also considered.

  10. A Comparative Study of Data Envelopment Analysis and Other Approaches to Efficiency Evaluation and Estimation.

    DTIC Science & Technology

    1982-11-01

    ADA27 91 A COMPARATIVE STJDO DATAENVEOPMENT ANALYSISAND / HER APPROACHES TO A .i)TEXAS UN VAT AUSIN CENTER FOCAS RE CCYR 5 NO BERRETIC STADIES A... COMPARATIVE STUDY OF DATA ENVELOPMENT ANALYSIS AND OTHER APPROACHES TO EFFICIENCY EVALUATION AND ESTIMATIONt by A. Charnes W.W. Cooper H.D. Sherman...School of Business, 1981, entitled "Measurement of Hospital Efficiency: A Comparative Analysis of Data Envelopment Analysis and Other Approaches for

  11. A novel estimating method for steering efficiency of the driver with electromyography signals

    NASA Astrophysics Data System (ADS)

    Liu, Yahui; Ji, Xuewu; Hayama, Ryouhei; Mizuno, Takahiro

    2014-05-01

    The existing research of steering efficiency mainly focuses on the mechanism efficiency of steering system, aiming at designing and optimizing the mechanism of steering system. In the development of assist steering system especially the evaluation of its comfort, the steering efficiency of driver physiological output usually are not considered, because this physiological output is difficult to measure or to estimate, and the objective evaluation of steering comfort therefore cannot be conducted with movement efficiency perspective. In order to take a further step to the objective evaluation of steering comfort, an estimating method for the steering efficiency of the driver was developed based on the research of the relationship between the steering force and muscle activity. First, the steering forces in the steering wheel plane and the electromyography (EMG) signals of the primary muscles were measured. These primary muscles are the muscles in shoulder and upper arm which mainly produced the steering torque, and their functions in steering maneuver were identified previously. Next, based on the multiple regressions of the steering force and EMG signals, both the effective steering force and the total force capacity of driver in steering maneuver were calculated. Finally, the steering efficiency of driver was estimated by means of the estimated effective force and the total force capacity, which represented the information of driver physiological output of the primary muscles. This research develops a novel estimating method for driver steering efficiency of driver physiological output, including the estimation of both steering force and the force capacity of primary muscles with EMG signals, and will benefit to evaluate the steering comfort with an objective perspective.

  12. Model Energy Efficiency Program Impact Evaluation Guide

    EPA Pesticide Factsheets

    Find guidance on model approaches for calculating energy, demand, and emissions savings resulting from energy efficiency programs. It describes several standard approaches that can be used in order to make these programs more efficient.

  13. LiDAR for data efficiency.

    DOT National Transportation Integrated Search

    2011-09-30

    This report documents the AHMCT research project: LiDAR for Data Efficiency for the Washington State Department of Transportation (WSDOT). The research objective was to evaluate mobile LiDAR technology to enhance safety, determine efficiency ga...

  14. Economical and technical efficiencies evaluation of full scale piggery wastewater treatment BNR plants.

    PubMed

    Oa, S W; Choi, E; Kim, S W; Kwon, K H; Min, K S

    2009-01-01

    A method evaluating the economic efficiency of piggery waste treatment plant based on kinetics for nitrogen removal performances is executed in this study and five full scale plants were evaluated, monitored intensively during one year under steady-state conditions. The performance data from those surveyed plants were recalculated by first-order kinetic equation instead of the Monod's equation, and the nitrogen removal kinetics related with COD/TKN ratios. Two plants adapting two extreme strategies for pre treatment, 'excess phase separation', and 'minimum phase separation', were evaluated by the assessment of life cycle cost (LCC). Although the compared two plants use an opposite strategy to each other, similar evaluation results are deduced by nitrogen removal efficiencies and operational and construction costs. But the proportions of constituent elements are as different as two opposite strategies, so electrical and construction costs are inversely proportional to chemical costs and operational costs respectively.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mundaca, Luis; Neij, Lena; Worrell, Ernst

    The growing complexities of energy systems, environmental problems and technology markets are driving and testing most energy-economy models to their limits. To further advance bottom-up models from a multidisciplinary energy efficiency policy evaluation perspective, we review and critically analyse bottom-up energy-economy models and corresponding evaluation studies on energy efficiency policies to induce technological change. We use the household sector as a case study. Our analysis focuses on decision frameworks for technology choice, type of evaluation being carried out, treatment of market and behavioural failures, evaluated policy instruments, and key determinants used to mimic policy instruments. Although the review confirms criticismmore » related to energy-economy models (e.g. unrealistic representation of decision-making by consumers when choosing technologies), they provide valuable guidance for policy evaluation related to energy efficiency. Different areas to further advance models remain open, particularly related to modelling issues, techno-economic and environmental aspects, behavioural determinants, and policy considerations.« less

  16. Research on Evaluation of resource allocation efficiency of transportation system based on DEA

    NASA Astrophysics Data System (ADS)

    Zhang, Zhehui; Du, Linan

    2017-06-01

    In this paper, we select the time series data onto 1985-2015 years, construct the land (shoreline) resources, capital and labor as inputs. The index system of the output is freight volume and passenger volume, we use Quantitative analysis based on DEA method evaluated the resource allocation efficiency of railway, highway, water transport and civil aviation in China. Research shows that the resource allocation efficiency of various modes of transport has obvious difference, and the impact on scale efficiency is more significant. The most important two ways to optimize the allocation of resources to improve the efficiency of the combination of various modes of transport is promoting the co-ordination of various modes of transport and constructing integrated transportation system.

  17. Efficiency of seed production in southern pine seed orchards

    Treesearch

    David L. Bramlett

    1977-01-01

    Seed production in southern pine seed orchards can be evaluated by estimating the efficiency of four separate stages of cone, seed, and seedling development. Calculated values are: cone efficiency (CE), the ratio of mature cones to the initial flower crop; seed efficiency (SE), the ratio of filled seeds per cone to the seed potential; extraction efficiency (EE), the...

  18. Energy efficient engine: Low-pressure turbine subsonic cascade component development and integration program

    NASA Technical Reports Server (NTRS)

    Sharma, O. P.; Kopper, F. C.; Knudsen, L. K.; Yustinich, J. B.

    1982-01-01

    A subsonic cascade test program was conducted to provide technical data for optimizing the blade and vane airfoil designs for the Energy Efficient Engine Low-Pressure Turbine component. The program consisted of three parts. The first involved an evaluation of the low-chamber inlet guide vane. The second, was an evaluation of two candidate aerodynamic loading philosophies for the fourth blade root section. The third part consisted of an evaluation of three candidate airfoil geometries for the fourth blade mean section. The performance of each candidate airfoil was evaluated in a linear cascade configuration. The overall results of this study indicate that the aft-loaded airfoil designs resulted in lower losses which substantiated Pratt & Whitney Aircraft's design philosophy for the Energy Efficient Engine low-pressure turbine component.

  19. High-Energy, Multi-Octave-Spanning Mid-IR Sources via Adiabatic Difference Frequency Generation

    DTIC Science & Technology

    2016-10-17

    plan. We have evaluated a brand -new concept in nonlinear optics, adiabatic difference frequency generation (ADFG) for the efficient transfer of...achieved the main goals of our research plan. We have evaluated a brand -new concept in nonlinear optics, adiabatic difference frequency generation (ADFG...research plan. We have evaluated a brand -new concept in nonlinear optics, adiabatic difference frequency generation (ADFG) for the efficient transfer of

  20. A Critical Analysis of Accountability in Higher Education: Its Relevance to Evaluation of Higher Education

    ERIC Educational Resources Information Center

    Kai, Jiang

    2009-01-01

    Accountability, which is closely related to evaluation of efficiency, effectiveness, and performance, requires proving that higher education has achieved planned results and performance in an effective manner. Highlighting efficiency and effectiveness and emphasizing results and outcomes are the basic characteristics of accountability in higher…

  1. EFFECT OF LOADING DUST TYPE ON THE FILTRATION EFFICIENCY OF ELECTROSTATICALLY CHARGED FILTERS

    EPA Science Inventory

    The paper gives results of an evaluation of the effect of loading dust type on the filtration efficiency of electrostatically charged filters. Three types of filters were evaluated: a rigid-cell filter charged using an electrodynamic spinning process, a pleated-panel filter cha...

  2. A prototype national cattle evaluation for feed intake and efficiency of Angus cattle

    USDA-ARS?s Scientific Manuscript database

    Recent development of technologies for measuring individual feed intake has made possible the collection of data suitable for breed-wide genetic evaluation. Goals of this research were to estimate genetic parameters for components of feed efficiency and develop a prototype system for conducting a ge...

  3. Chapter 4: Small Commercial and Residential Unitary and Split System HVAC Heating and Cooling Equipment-Efficiency Upgrade Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurnik, Charles W; Jacobson, David; Metoyer, Jarred

    The specific measure described here involves improving the overall efficiency in air-conditioning systems as a whole (compressor, evaporator, condenser, and supply fan). The efficiency rating is expressed as the energy efficiency ratio (EER), seasonal energy efficiency ratio (SEER), and integrated energy efficiency ratio (IEER). The higher the EER, SEER or IEER, the more efficient the unit is.

  4. Evaluating the process parameters of the dry coating process using a 2(5-1) factorial design.

    PubMed

    Kablitz, Caroline Désirée; Urbanetz, Nora Anne

    2013-02-01

    A recent development of coating technology is dry coating, where polymer powder and liquid plasticizer are layered on the cores without using organic solvents or water. Several studies evaluating the process were introduced in literature, however, little information about the critical process parameters (CPPs) is given. Aim of the study was the investigation and optimization of CPPs with respect to one of the critical quality attributes (CQAs), the coating efficiency of the dry coating process in a rotary fluid bed. Theophylline pellets were coated with hydroxypropyl methylcellulose acetate succinate as enteric film former and triethyl citrate and acetylated monoglyceride as plasticizer. A 2(5-1) design of experiments (DOEs) was created investigating five independent process parameters namely coating temperature, curing temperature, feeding/spraying rate, air flow and rotor speed. The results were evaluated by multilinear regression using the software Modde(®) 7. It is shown, that generally, low feeding/spraying rates and low rotor speeds increase coating efficiency. High coating temperatures enhance coating efficiency, whereas medium curing temperatures have been found to be optimum in terms of coating efficiency. This study provides a scientific base for the design of efficient dry coating processes with respect to coating efficiency.

  5. Evaluation of food drying with air dehumidification system: a short review

    NASA Astrophysics Data System (ADS)

    Djaeni, M.; Utari, F. D.; Sasongko, S. B.; Kumoro, A. C.

    2018-01-01

    Energy efficient drying for food and agriculture products resulting high quality products has been an important issue. Currently, about 50% of total energy for postharvest treatment was used for drying. This paper presents the evaluation of new approach namely air dehumidification system with zeolite for food drying. Zeolite is a material having affinity to water in which reduced the moisture in air. With low moisture content and relative humidity, the air can improve driving force for drying even at low temperature. Thus, the energy efficiency can be potentially enhanced and the product quality can be well retained. For proving the hypothesis, the paddy and onion have been dried using dehumidified air. As performance indicators, the drying time, product quality, and heat efficiency were evaluated. Results indicated that the drying with zeolite improved the performances significantly. At operating temperature ranging 50 - 60°C, the efficiency of drying system can reach 75% with reasonable product quality.

  6. Experimental evaluation of cooling efficiency of the high performance cooling device

    NASA Astrophysics Data System (ADS)

    Nemec, Patrik; Malcho, Milan

    2016-06-01

    This work deal with experimental evaluation of cooling efficiency of cooling device capable transfer high heat fluxes from electric elements to the surrounding. The work contain description of cooling device, working principle of cooling device, construction of cooling device. Experimental part describe the measuring method of device cooling efficiency evaluation. The work results are presented in graphic visualization of temperature dependence of the contact area surface between cooling device evaporator and electronic components on the loaded heat of electronic components in range from 250 to 740 W and temperature dependence of the loop thermosiphon condenser surface on the loaded heat of electronic components in range from 250 to 740 W.

  7. Improving smoothing efficiency of rigid conformal polishing tool using time-dependent smoothing evaluation model

    NASA Astrophysics Data System (ADS)

    Song, Chi; Zhang, Xuejun; Zhang, Xin; Hu, Haifei; Zeng, Xuefeng

    2017-06-01

    A rigid conformal (RC) lap can smooth mid-spatial-frequency (MSF) errors, which are naturally smaller than the tool size, while still removing large-scale errors in a short time. However, the RC-lap smoothing efficiency performance is poorer than expected, and existing smoothing models cannot explicitly specify the methods to improve this efficiency. We presented an explicit time-dependent smoothing evaluation model that contained specific smoothing parameters directly derived from the parametric smoothing model and the Preston equation. Based on the time-dependent model, we proposed a strategy to improve the RC-lap smoothing efficiency, which incorporated the theoretical model, tool optimization, and efficiency limit determination. Two sets of smoothing experiments were performed to demonstrate the smoothing efficiency achieved using the time-dependent smoothing model. A high, theory-like tool influence function and a limiting tool speed of 300 RPM were o

  8. Efficiency evaluation with feedback for regional water use and wastewater treatment

    NASA Astrophysics Data System (ADS)

    Hu, Zhineng; Yan, Shiyu; Yao, Liming; Moudi, Mahdi

    2018-07-01

    Clean water is crucial for sustainable economic and social development; however, around the world low water use efficiency and increasing water pollution have become serious problems. To comprehensively evaluate water use and wastewater treatment, this paper integrated bi-level programming (BLP) and Data Envelopment Analysis (DEA) with a feedback variable to deal with poor output to rank DMUs using a super efficiency DEA. The proposed model was applied to a case study of 10 cities in the Minjiang River Basin to demonstrate the applicability and effectiveness, from which it was found that a water system can only be cost-efficient when both the water use and wastewater treatment subsystems are both cost-efficient. The comparison analysis demonstrated that the proposed model was more discriminating, and stable than traditional DEA models and was able to better improve total water system cost efficiencies than a BLP-DEA model.

  9. Planning Strategies for Transportation Fuel Consumption Reduction: An Evaluation of the Hawaii Clean Energy Initiative’s Transportation Plan

    DTIC Science & Technology

    2014-04-01

    technologies to improve fleet efficiency goals, and evaluate switching to biodiesel for trucks and vehicles without other alternatives (HCEI 2011...standards and biodiesel usage levels 2020 Goal 50 MGY of renewable fuels 28 working with industry to increase EV market penetration, and...Strategy Reduction Potential Purchase more efficient vehicles 10-20% Promote hybrid technologies 10-20% Evaluate biodiesel switching (freight) TBD

  10. Susceptibility constants of airborne bacteria to dielectric barrier discharge for antibacterial performance evaluation.

    PubMed

    Park, Chul Woo; Hwang, Jungho

    2013-01-15

    Dielectric barrier discharge (DBD) is a promising method to remove contaminant bioaerosols. The collection efficiency of a DBD reactor is an important factor for determining a reactor's removal efficiency. Without considering collection, simply defining the inactivation efficiency based on colony counting numbers for DBD as on and off may lead to overestimation of the inactivation efficiency of the DBD reactor. One-pass removal tests of bioaerosols were carried out to deduce the inactivation efficiency of the DBD reactor using both aerosol- and colony-counting methods. Our DBD reactor showed good performance for removing test bioaerosols for an applied voltage of 7.5 kV and a residence time of 0.24s, with η(CFU), η(Number), and η(Inactivation) values of 94%, 64%, and 83%, respectively. Additionally, we introduce the susceptibility constant of bioaerosols to DBD as a quantitative parameter for the performance evaluation of a DBD reactor. The modified susceptibility constant, which is the ratio of the susceptibility constant to the volume of the plasma reactor, has been successfully demonstrated for the performance evaluation of different sized DBD reactors under different DBD operating conditions. Our methodology will be used for design optimization, performance evaluation, and prediction of power consumption of DBD for industrial applications. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Towards a Cloud Based Smart Traffic Management Framework

    NASA Astrophysics Data System (ADS)

    Rahimi, M. M.; Hakimpour, F.

    2017-09-01

    Traffic big data has brought many opportunities for traffic management applications. However several challenges like heterogeneity, storage, management, processing and analysis of traffic big data may hinder their efficient and real-time applications. All these challenges call for well-adapted distributed framework for smart traffic management that can efficiently handle big traffic data integration, indexing, query processing, mining and analysis. In this paper, we present a novel, distributed, scalable and efficient framework for traffic management applications. The proposed cloud computing based framework can answer technical challenges for efficient and real-time storage, management, process and analyse of traffic big data. For evaluation of the framework, we have used OpenStreetMap (OSM) real trajectories and road network on a distributed environment. Our evaluation results indicate that speed of data importing to this framework exceeds 8000 records per second when the size of datasets is near to 5 million. We also evaluate performance of data retrieval in our proposed framework. The data retrieval speed exceeds 15000 records per second when the size of datasets is near to 5 million. We have also evaluated scalability and performance of our proposed framework using parallelisation of a critical pre-analysis in transportation applications. The results show that proposed framework achieves considerable performance and efficiency in traffic management applications.

  12. On Improving Efficiency of Differential Evolution for Aerodynamic Shape Optimization Applications

    NASA Technical Reports Server (NTRS)

    Madavan, Nateri K.

    2004-01-01

    Differential Evolution (DE) is a simple and robust evolutionary strategy that has been proven effective in determining the global optimum for several difficult optimization problems. Although DE offers several advantages over traditional optimization approaches, its use in applications such as aerodynamic shape optimization where the objective function evaluations are computationally expensive is limited by the large number of function evaluations often required. In this paper various approaches for improving the efficiency of DE are reviewed and discussed. These approaches are implemented in a DE-based aerodynamic shape optimization method that uses a Navier-Stokes solver for the objective function evaluations. Parallelization techniques on distributed computers are used to reduce turnaround times. Results are presented for the inverse design of a turbine airfoil. The efficiency improvements achieved by the different approaches are evaluated and compared.

  13. Evaluation of high-energy-efficiency powertrain approaches: the 1996 futurecar challenge

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sluder, S.; Duoba, M.; Larsen, R.

    Twelve colleges and universities were selected to design, build, and develop a mid-size vehicle that could achieve high energy economy while maintaining the performance characteristics of today`s mid-size vehicle. Many of the teams were able to increase the fuel economy of their vehicles, but most of these increases came at the expense of decreased performance or worsened emissions. This paper evaluates and summarizes the high-energy-efficiency powertrain technology approaches that were utilized in the 1996 FutureCar Challenge, which was the first evaluation of these vehicles in a two-year program. Of the 11 vehicles evaluated in the competition, nine utilized hybrid electricmore » vehicle approaches. This paper discusses the design trade- offs made by the teams to achieve high efficiency while trying to maintain stock performance.« less

  14. State Energy Efficiency Program Evaluation Inventory

    EIA Publications

    2013-01-01

    The focus of this inventory, some of which has been placed into a searchable spreadsheet, is to support the National Energy Modeling System (NEMS) and to research cost information in state-mandated energy efficiency program evaluations – e.g., for use in updating analytic and modeling assumptions used by the U.S. Energy Information Administration (EIA).

  15. Dry bean genotype evaluation for growth, yield components and phosphorus use efficiency

    USDA-ARS?s Scientific Manuscript database

    Dry beans along with rice are staple food for populations of South America. In this tropical region beans are grown on Oxisols and phosphorus is one of the most yield limiting factors for dry bean production. A greenhouse experiment was conducted to evaluate P use efficiency in 20 promising dry bean...

  16. Efficiency Analysis: Enhancing the Statistical and Evaluative Power of the Regression-Discontinuity Design.

    ERIC Educational Resources Information Center

    Madhere, Serge

    An analytic procedure, efficiency analysis, is proposed for improving the utility of quantitative program evaluation for decision making. The three features of the procedure are explained: (1) for statistical control, it adopts and extends the regression-discontinuity design; (2) for statistical inferences, it de-emphasizes hypothesis testing in…

  17. An evaluation of multipass electrofishing for estimating the abundance of stream-dwelling salmonids

    Treesearch

    James T. Peterson; Russell F. Thurow; John W. Guzevich

    2004-01-01

    Failure to estimate capture efficiency, defined as the probability of capturing individual fish, can introduce a systematic error or bias into estimates of fish abundance. We evaluated the efficacy of multipass electrofishing removal methods for estimating fish abundance by comparing estimates of capture efficiency from multipass removal estimates to capture...

  18. Robotics Scoping Study to Evaluate Advances in Robotics Technologies that Support Enhanced Efficiencies for Yucca Mountain Repository Operations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    T. Burgess; M. Noakes; P. Spampinato

    This paper presents an evaluation of robotics and remote handling technologies that have the potential to increase the efficiency of handling waste packages at the proposed Yucca Mountain High-Level Nuclear Waste Repository. It is expected that increased efficiency will reduce the cost of operations. The goal of this work was to identify technologies for consideration as potential projects that the U.S. Department of Energy Office of Civilian Radioactive Waste Management, Office of Science and Technology International Programs, could support in the near future, and to assess their ''payback'' value. The evaluation took into account the robotics and remote handling capabilitiesmore » planned for incorporation into the current baseline design for the repository, for both surface and subsurface operations. The evaluation, completed at the end of fiscal year 2004, identified where significant advantages in operating efficiencies could accrue by implementing any given robotics technology or approach, and included a road map for a multiyear R&D program for improvements to remote handling technology that support operating enhancements.« less

  19. Why Do Health Economists Promote Technology Adoption Rather Than the Search for Efficiency? A Proposal for a Change in Our Approach to Economic Evaluation in Health Care.

    PubMed

    Scotland, Graham; Bryan, Stirling

    2017-02-01

    At a time of intense pressure on health care budgets, the technology management challenge is for disinvestment in low-value technologies and reinvestment in higher value alternatives. The aim of this article is to explore ways in which health economists might begin to redress the observed imbalance between the evaluation of new and existing in-use technologies. The argument is not against evaluating new technologies but in favor of the "search for efficiency," where the ultimate objective is to identify reallocations that improve population health in the face of resource scarcity. We explore why in-use technologies may be of low value and consider how economic evaluation analysts might embrace a broader efficiency lens, first through "technology management" (a process of analysis and evidence-informed decision making throughout a technology's life cycle) and progressing through "pathway management" (the search for efficiency gains across entire clinical care pathways). A number of model-based examples are used to illustrate the approaches.

  20. Evaluation on the Efficiency of Biomass Power Generation Industry in China

    PubMed Central

    Sun, Dong; Guo, Sen

    2014-01-01

    As a developing country with large population, China is facing the problems of energy resource shortage and growing environmental pollution arising from the coal-dominated energy structure. Biomass energy, as a kind of renewable energy with the characteristics of being easy to store and friendly to environment, has become the focus of China's energy development in the future. Affected by the advanced power generation technology and diversified geography environment, the biomass power generation projects show new features in recent years. Hence, it is necessary to evaluate the efficiency of biomass power generation industry by employing proper method with the consideration of new features. In this paper, the regional difference as a new feature of biomass power generation industry is taken into consideration, and the AR model is employed to modify the zero-weight issue when using data envelopment analysis (DEA) method to evaluate the efficiency of biomass power generation industry. 30 biomass power generation enterprises in China are selected as the sample, and the efficiency evaluation is performed. The result can provide some insights into the sustainable development of biomass power generation industry in China. PMID:25093209

  1. Voluntary medical male circumcision scale-up in Nyanza, Kenya: evaluating technical efficiency and productivity of service delivery.

    PubMed

    Omondi Aduda, Dickens S; Ouma, Collins; Onyango, Rosebella; Onyango, Mathews; Bertrand, Jane

    2015-01-01

    Voluntary medical male circumcision (VMMC) service delivery is complex and resource-intensive. In Kenya's context there is still paucity of information on resource use vis-à-vis outputs as programs scale up. Knowledge of technical efficiency, productivity and potential sources of constraints is desirable to improve decision-making. To evaluate technical efficiency and productivity of VMMC service delivery in Nyanza in 2011/2012 using data envelopment analysis. Comparative process evaluation of facilities providing VMMC in Nyanza in 2011/2012 using output orientated data envelopment analysis. Twenty one facilities were evaluated. Only 1 of 7 variables considered (total elapsed operation time) significantly improved from 32.8 minutes (SD 8.8) in 2011 to 30 minutes (SD 6.6) in 2012 (95%CI = 0.0350-5.2488; p = 0.047). Mean scale technical efficiency significantly improved from 91% (SD 19.8) in 2011 to 99% (SD 4.0) in 2012 particularly among outreach compared to fixed service delivery facilities (CI -31.47959-4.698508; p = 0.005). Increase in mean VRS technical efficiency from 84% (SD 25.3) in 2011 and 89% (SD 25.1) in 2012 was not statistically significant. Benchmark facilities were #119 and #125 in 2011 and #103 in 2012. Malmquist Productivity Index (MPI) at fixed facilities declined by 2.5% but gained by 4.9% at outreach ones by 2012. Total factor productivity improved by 83% (p = 0.032) in 2012, largely due to progress in technological efficiency by 79% (p = 0.008). Significant improvement in scale technical efficiency among outreach facilities in 2012 was attributable to accelerated activities. However, ongoing pure technical inefficiency requires concerted attention. Technological progress was the key driver of service productivity growth in Nyanza. Incorporating service-quality dimensions and using stepwise-multiple criteria in performance evaluation enhances comprehensiveness and validity. These findings highlight site-level resource use and sources of variations in VMMC service productivity, which are important for program planning.

  2. Factors that influence the efficiency of beef and dairy cattle recording system in Kenya: A SWOT-AHP analysis.

    PubMed

    Wasike, Chrilukovian B; Magothe, Thomas M; Kahi, Alexander K; Peters, Kurt J

    2011-01-01

    Animal recording in Kenya is characterised by erratic producer participation and high drop-out rates from the national recording scheme. This study evaluates factors influencing efficiency of beef and dairy cattle recording system. Factors influencing efficiency of animal identification and registration, pedigree and performance recording, and genetic evaluation and information utilisation were generated using qualitative and participatory methods. Pairwise comparison of factors was done by strengths, weaknesses, opportunities and threats-analytical hierarchical process analysis and priority scores to determine their relative importance to the system calculated using Eigenvalue method. For identification and registration, and evaluation and information utilisation, external factors had high priority scores. For pedigree and performance recording, threats and weaknesses had the highest priority scores. Strengths factors could not sustain the required efficiency of the system. Weaknesses of the system predisposed it to threats. Available opportunities could be explored as interventions to restore efficiency in the system. Defensive strategies such as reorienting the system to offer utility benefits to recording, forming symbiotic and binding collaboration between recording organisations and NARS, and development of institutions to support recording were feasible.

  3. The Efficiency of Higher Education Institutions in England Revisited: Comparing Alternative Measures

    ERIC Educational Resources Information Center

    Johnes, Geraint; Tone, Kaoru

    2017-01-01

    Data envelopment analysis (DEA) has often been used to evaluate efficiency in the context of higher education institutions. Yet there are numerous alternative non-parametric measures of efficiency available. This paper compares efficiency scores obtained for institutions of higher education in England, 2013-2014, using three different methods: the…

  4. Procedures to evaluate the efficiency of protective clothing worn by operators applying pesticide.

    PubMed

    Espanhol-Soares, Melina; Nociti, Leticia A S; Machado-Neto, Joaquim Gonçalves

    2013-10-01

    The evaluation of the efficiency of whole-body protective clothing against pesticides has already been carried out through field tests and procedures defined by international standards, but there is a need to determine the useful life of these garments to ensure worker safety. The aim of this article is to compare the procedures for evaluating efficiency of two whole-body protective garments, both new and previously used by applicators of herbicides, using a laboratory test with a mannequin and in the field with the operator. The evaluation of the efficiency of protective clothing used both quantitative and qualitative methodologies, leading to a proposal for classification according to efficiency, and determination of the useful life of protective clothing for use against pesticides, based on a quantitative assessment. The procedures used were in accordance with the standards of the modified American Society for Testing and Materials (ASTM) F 1359:2007 and International Organization for Standardization 17491-4. The protocol used in the field was World Health Organization Vector Biology and Control (VBC)/82.1. Clothing tested was personal water repellent and pesticide protective. Two varieties of fabric were tested: Beige (100% cotton) and Camouflaged (31% polyester and 69% cotton). The efficiency in exposure control of the personal protective clothing was measured before use and after 5, 10, 20, and 30 uses and washes under field conditions. Personal protective clothing was worn by workers in the field during the application of the herbicide glyphosate on weed species in mature sugar cane plantations using a knapsack sprayer. The modified ASTM 1359:2007 procedure was chosen as the most appropriate due to its greater repeatability (lower coefficient of variation). This procedure provides quantitative evaluation needed to determine the efficiency and useful life of individual protective clothing, not just at specific points of failure, but according to dermal protection as a whole. The qualitative assessment, which is suitable for verification of garment design and stitching flaws, does not aid in determining useful life, but does complement the quantitative evaluation. The proposed classification is appropriate and accurate for determining the useful life of personal protective clothing against pesticide materials relative to number of uses and washes after each use. For example, the Beige garment had a useful life of 30 uses and washes, while the Camouflaged garment had a useful life of 5 uses and washes. The quantitative evaluation aids in determining the efficiency and useful life of individual protective clothing according to dermal protection as a whole, not just at specific points of failure.

  5. Energy and Environment Guide to Action - Chapter 4.3: Building Codes for Energy Efficiency

    EPA Pesticide Factsheets

    Provides guidance and recommendations for establishing, implementing, and evaluating state building codes for energy efficiency, which improve energy efficiency in new construction and major renovations. State success stories are included for reference.

  6. International Review of Frameworks for Impact Evaluation of Appliance Standards, Labeling, and Incentives

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, Nan; Romankiewicz, John; Vine, Edward

    2012-12-15

    In recent years, the number of energy efficiency policies implemented has grown very rapidly as energy security and climate change have become top policy issues for many governments around the world. Within the sphere of energy efficiency policy, governments (federal and local), electric utilities, and other types of businesses and institutions are implementing a wide variety of programs to spread energy efficiency practices in industry, buildings, transport, and electricity. As programs proliferate, there is an administrative and business imperative to evaluate the savings and processes of these programs to ensure that program funds spent are indeed leading to a moremore » energy-efficient economy.« less

  7. [Catheter-related bladder discomfort after urological surgery: importance of the type of surgery and efficiency of treatment by clonazepam].

    PubMed

    Maro, S; Zarattin, D; Baron, T; Bourez, S; de la Taille, A; Salomon, L

    2014-09-01

    Bladder catheter can induce a Catheter-Related Bladder Discomfort (CRBD). Antagonist of muscarinic receptor is the gold standard treatment. Clonazepam is an antimuscarinic, muscle relaxing oral drug. The aim of this study is to look for a correlation between the type of surgical procedure and the existence of CRBD and to evaluate the efficiency of clonazepam. One hundred patients needing bladder catheter were evaluated. Sexe, age, BMI, presence of diabetes, surgical procedure and existence of CRBD were noted. Pain was evaluated with analogic visual scale. Timing of pain, need for specific treatment by clonazepam and its efficiency were noted. Correlation between preoperative data, type of surgical procedure, existence of CRBD and efficiency of treatment were evaluated. There were 79 men and 21 women (age: 65.9 years, BMI: 25.4). Twelve patients presented diabetes. Surgical procedure concerned prostate in 39 cases, bladder in 19 cases (tumor resections), endo-urology in 20 cases, upper urinary tract in 12 cases (nephrectomy…) and lower urinary tract in 10 cases (sphincter, sub-uretral tape). Forty patients presented CRBD, (pain 4.5 using VAS). This pain occurred 0.6 days after surgery. No correlation was found between preoperative data and CRBD. Bladder resection and endo-urological procedures were surgical procedures which procured CRBD. Clonazepam was efficient in 30 (75 %) out of 40 patients with CRBD. However, it was less efficient in case of bladder tumor resection. CRBD is frequent and occurred immediately after surgery. Bladder resection and endo-urology were the main surgical procedures which induced CRBD. Clonazepam is efficient in 75 %. Bladder resection is the surgical procedure which is the most refractory to treatment. 5. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  8. Evaluation of a bulk calorimeter and heat balance for determination of supersonic combustor efficiency

    NASA Technical Reports Server (NTRS)

    Mcclinton, C. R.; Anderson, G. Y.

    1980-01-01

    Results are presented from the shakedown and evaluation test of a bulk calorimeter. The calorimeter is designed to quench the combustion at the exit of a direct-connect, hydrogen fueled, scramjet combustor model, and to provide the measurements necessary to perform an analysis of combustion efficiency. Results indicate that the calorimeter quenches reaction, that reasonable response times are obtained, and that the calculated combustion efficiency is repeatable within + or -3 percent and varies in a regular way with combustor model parameters such as injected fuel equivalence ratio.

  9. Evaluation of antitumor efficiency of experimental interstitial photodynamic therapy on the model of M1 sarcoma.

    PubMed

    Skugareva, O A; Kaplan, M A; Malygina, A I; Mikhailovskaya, A A

    2009-11-01

    Antitumor efficiency of interstitial photodynamic therapy was evaluated in experiments on outbred albino rats with implanted M-1 sarcoma. Interstitial photodynamic therapy was carried out using one diffusor at different output power and duration of exposure. The percentage of complete regression of the tumors increased with increasing exposure parameters.

  10. 40 CFR 63.1426 - Process vent requirements for determining organic HAP concentration, control efficiency, and...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... performance test for those control techniques in accordance with paragraph (b)(6) of this section. The design..., immediately preceding the use of the control technique. A design evaluation shall also address other vent... paragraph (f)(1)(i) of this section, the design evaluation shall document the control efficiency and address...

  11. Histological method for evaluation of the efficiency of Enerlit-Clima.

    PubMed

    Gol'dshtein, D V; Vikhlyantseva, E V; Sakharova, N K; Maevskii, E I; Pogorelov, A G; Uchitel', M L

    2004-08-01

    We propose a method of evaluation of anticlimacteric efficiency of a drug by its effect on the estrous cycle. The study was carried out on 9-month-old mice with retained, but notably reduced reproductive function. Analysis of the cell components of the estrous cycle was carried out on histological preparations of vaginal smears.

  12. [Evaluating efficiency of influenza vaccinal prevention among oil and gas industry workers].

    PubMed

    Bulanov, V E; Ivanov, A V; Shostak, G R

    2013-01-01

    Explore information about the incidence of employees of enterprises of the oil and gas industry with the influenza (SARS). The degree of influence of vaccination on the incidence of influenza, the number and structure of complications as a result of vaccination and their impact on efficiency. Evaluation of the cost-effectiveness of vaccination.

  13. The Integration of Environmental Education and Communicative English Based on Multiple Intelligence Theory for Students in Extended Schools

    ERIC Educational Resources Information Center

    Sangsongfa, Chalothorn; Rawang, Wee

    2016-01-01

    Research and Development (R&D) was used with 364 students, 44 teachers and 3 school directors before designing innovation, and evaluating the model efficiency with 30 voluntary students by Action Research (AR). The research used questionnaire, interview form and innovation efficiency evaluation form, and statistically analyzed by percentage,…

  14. Measurement and evaluation of percolation drainage systems capacity in real conditions

    NASA Astrophysics Data System (ADS)

    Markovic, G.; Zelenakova, M.

    2017-10-01

    The drainage system must ensure a safe disposal of the surface water without endangering the buildings and safety of people. Despite the common use of rainwater infiltration facilities, there is still only limited data available evaluating the long-term capacity of such systems especially for underground infiltration facilities. This study presents experimental measurements and evaluation of long-term infiltration efficiency in real conditions and emphasizes the importance of hydrogeological survey. The measurements of infiltration efficiency were applied to an existing percolation drainage system - infiltration shafts. Infiltration shafts were made in year 2007 so that its drainage operation takes more than 8 years. This study was started in 2011 and still continues and presents 5 years measurements of infiltration efficiency for this infiltration facility.

  15. Evaluation of cutting efficiency of ultrasonic tips used in orthograde endodontic treatment.

    PubMed

    Lin, Yu-Heng; Mickel, André K; Jones, Jefferson J; Montagnese, Thomas A; González, Alvaro F

    2006-04-01

    The purpose of the present study was to evaluate the cutting efficiency of the three different ultrasonic tips for orthograde endodontic treatment: stainless steel, zirconium nitride-coated, and diamond-coated tips. An ultrasonic handpiece was mounted on a custom-made automated balance, and each tip repeatedly penetrated dental stone blocks to a depth of 3 mm for 10 times. The amount of time taken to penetrate 3 mm of stone was measured. The diamond-coated tips showed significantly greater cutting efficiency than either stainless steel tips or zirconium-nitride coated tips. The stainless steel tips showed initial better cutting efficiency, but over time , there is no significant difference between the cutting efficiency of the stainless steel tips and the zirconium nitride coated tips. The diamond coated tips were the only group that showed breakage in this study.

  16. Approches pour la reduction de l'impact de defaut dans le transport d'energie du parc eolien offshore via VSC-HVDC =

    NASA Astrophysics Data System (ADS)

    Benadja, Mounir

    Dans ce travail est presente un systeme de generation d'energie d'un parc eolien offshore et un systeme de transport utilisant les stations VSC-HVDC connectees au reseau principal AC onshore. Trois configurations ont ete etudiees, modelisees et validees par simulation. Dans chacune des configurations, des contributions ameliorant les cotes techniques et economiques sont decrites ci-dessous : La premiere contribution concerne un nouvel algorithme MPPT (Maximum Power Point Tracking) utilise pour l'extraction de la puissance maximale disponible dans les eoliennes des parcs offshores. Cette technique d'extraction du MPPT ameliore le rendement energetique de la chaine de conversion des energies renouvelables notamment l'energie eolienne a petite et a grande echelles (parc eolien offshore) qui constitue un probleme pour les constructeurs qui se trouvent confrontes a developper des dispositifs MPPT simples, moins couteux, robustes, fiables et capable d'obtenir un rendement energetique maximal. La deuxieme contribution concerne la reduction de la taille, du cout et de l'impact des defauts electriques (AC et DC) dans le systeme construit pour transporter l'energie d'un parc eolien offshore (OWF) vers le reseau principal AC onshore via deux stations 3L-NPC VSCHVDC. La solution developpee utilise des observateurs non-lineaires bases sur le filtre de Kalman etendu (EKF). Ce filtre permet d'estimer la vitesse de rotation et la position du rotor de chacune des generatrices du parc eolien offshore et de la tension du bus DC de l'onduleur DC-AC offshore et des deux stations 3L-NPC-VSC-HVDC (offshore et onshore). De plus, ce developpement du filtre de Kalman etendu a permis de reduire l'impact des defauts AC et DC. Deux commandes ont ete utilisees, l'une (commande indirect dans le plan abc) avec EKF integre destinee pour controler le convertisseur DC-AC offshore et l'autre (commande d-q) avec EKF integre pour controler les convertisseurs des deux stations AC-DC et DC-AC tout en tenant compte des entrees de chacune des stations. L'integration des observateurs non-lineaires (EKF) dans le controle des convertisseurs permet de resoudre le probleme des incertitudes de mesure, des incertitudes dans la modelisation, en cas du dysfonctionnement ou de panne des capteurs de mesure ainsi que le probleme de l'impact des defauts (AC et DC) sur la qualite d'energie dans les systemes de transmission. Ces estimations contribuent a rendre le cout global du systeme moins cher et sa taille moins encombrante ainsi que la reduction de l'impact des defauts (AC et DC) sur le systeme. La troisieme contribution concerne la reduction de la taille, du cout et de l'impact des defauts electriques (AC et DC) dans le systeme construit pour transporter l'energie d'un parc eolien offshore (OWF) vers le reseau principal AC onshore via deux stations VSC-HVDC. La solution developpee utilise des observateurs non-lineaires bases sur le filtre de Kalman etendu (EKF). Ce filtre permet d'estimer la vitesse de rotation et la position du rotor de chacune des generatrices du parc eolien et de la tension du bus DC de l'onduleur DC-AC offshore. La contribution porte surtout sur le developpement des deux commandes des deux stations. La premiere, la commande non-lineaire modifiee pour controler le premier convertisseur de la station VSC-HVDC offshore assurant le transfert de la puissance generee par le parc eolien vers la station VSC-HVDC onshore. La deuxieme commande non-lineaire modifiee avec integration de la regulation de la tension du bus DC et de la commande a modele de reference adaptative (MRAC) pour la compensation des surintensites et surtensions durant les defauts AC et DC. On peut constater que lors d'un defaut AC au PCC (Point of Common Coupling) du cote reseau onshore, la profondeur de l'impact du defaut AC sur l'amplitude des courants du reseau principal AC onshore qui etait reduit a 60% par les travaux de recherche (Erlich, Feltes et Shewarega, 2014), comparativement a la nouvelle commande proposee MRAC qui reduit la profondeur de l'impact a 35%. Lors de l'apparition des defauts AC et DC, une reduction de l'impact des defauts sur l'amplitude des courants de reseau AC terrestre et du temps de reponse a ete observee et la stabilite du systeme a ete renforcee par l'utilisation de la commande adaptative basee sur le modele de reference MRAC. La quatrieme contribution concerne une nouvelle commande basee sur le mode de glissement (SM) appliquee pour la station VSC-HVDC qui relie le parc eolien offshore (OWF) au reseau principal AC. Ce parc est compose de dix eoliennes basees sur des generatrices synchrones a aimant permanent (VSWT/PMSGs) connectees en parallele et chacune est controlee par son propre convertisseur DC-DC. Une comparaison des performances entre la commande SM et de la commande non-lineaire avec des controleurs PI pour les deux conditions (presence et absence de defaut DC) a ete analysee et montre la superiorite de la commande par SM. Un prototype du systeme etudie a echelle reduite a ete realise et teste au laboratoire GREPCI en utilisant la carte dSPACE-DS1104 pour la validation experimentale. L'analyse et la simulation des systemes etudies sont developpees sous l'environnement Matlab/Simulink/Simpowersystem. Les resultats obtenus a partir des configurations developpees sont valides par simulation et par experimentation. Les performances sont tres satisfaisantes du point de vue reponse dynamique, reponse en regime permanent, stabilite du systeme et qualite de l'energie.

  17. Assessing the Efficiency of Secondary Schools in Chile: A Data Envelopment Analysis

    ERIC Educational Resources Information Center

    Munoz, David Andres; Queupil, Juan Pablo

    2016-01-01

    Purpose: The purpose of this paper was to evaluate the efficiency of secondary education schools in Chile. Since the early 1980s, several educational reforms have been passed with the main objective of improving the quality, equity and efficiency of the Chilean education system. This has initiated a debate about the efficient use of public…

  18. On Improving Efficiency of Differential Evolution for Aerodynamic Shape Optimization Applications

    NASA Technical Reports Server (NTRS)

    Madavan, Nateri K.

    2004-01-01

    Differential Evolution (DE) is a simple and robust evolutionary strategy that has been provEn effective in determining the global optimum for several difficult optimization problems. Although DE offers several advantages over traditional optimization approaches, its use in applications such as aerodynamic shape optimization where the objective function evaluations are computationally expensive is limited by the large number of function evaluations often required. In this paper various approaches for improving the efficiency of DE are reviewed and discussed. Several approaches that have proven effective for other evolutionary algorithms are modified and implemented in a DE-based aerodynamic shape optimization method that uses a Navier-Stokes solver for the objective function evaluations. Parallelization techniques on distributed computers are used to reduce turnaround times. Results are presented for standard test optimization problems and for the inverse design of a turbine airfoil. The efficiency improvements achieved by the different approaches are evaluated and compared.

  19. Energy efficiency evaluation of a stationary lithium-ion battery container storage system via electro-thermal modeling and detailed component analysis

    DOE PAGES

    Schimpe, Michael; Naumann, Maik; Truong, Nam; ...

    2017-11-08

    Energy efficiency is a key performance indicator for battery storage systems. A detailed electro-thermal model of a stationary lithium-ion battery system is developed and an evaluation of its energy efficiency is conducted. The model offers a holistic approach to calculating conversion losses and auxiliary power consumption. Sub-models for battery rack, power electronics, thermal management as well as the control and monitoring components are developed and coupled to a comprehensive model. The simulation is parametrized based on a prototype 192 kWh system using lithium iron phosphate batteries connected to the low voltage grid. The key loss mechanisms are identified, thoroughly analyzedmore » and modeled. Generic profiles featuring various system operation modes are evaluated to show the characteristics of stationary battery systems. Typically the losses in the power electronics outweigh the losses in the battery at low power operating points. The auxiliary power consumption dominates for low system utilization rates. For estimation of real-world performance, the grid applications Primary Control Reserve, Secondary Control Reserve and the storage of surplus photovoltaic power are evaluated. Conversion round-trip efficiency is in the range of 70-80%. Finally, overall system efficiency, which also considers system power consumption, is 8-13 percentage points lower for Primary Control Reserve and the photovoltaic-battery application. However, for Secondary Control Reserve, the total round-trip efficiency is found to be extremely low at 23% due to the low energy throughput of this application type.« less

  20. Energy efficiency evaluation of a stationary lithium-ion battery container storage system via electro-thermal modeling and detailed component analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schimpe, Michael; Naumann, Maik; Truong, Nam

    Energy efficiency is a key performance indicator for battery storage systems. A detailed electro-thermal model of a stationary lithium-ion battery system is developed and an evaluation of its energy efficiency is conducted. The model offers a holistic approach to calculating conversion losses and auxiliary power consumption. Sub-models for battery rack, power electronics, thermal management as well as the control and monitoring components are developed and coupled to a comprehensive model. The simulation is parametrized based on a prototype 192 kWh system using lithium iron phosphate batteries connected to the low voltage grid. The key loss mechanisms are identified, thoroughly analyzedmore » and modeled. Generic profiles featuring various system operation modes are evaluated to show the characteristics of stationary battery systems. Typically the losses in the power electronics outweigh the losses in the battery at low power operating points. The auxiliary power consumption dominates for low system utilization rates. For estimation of real-world performance, the grid applications Primary Control Reserve, Secondary Control Reserve and the storage of surplus photovoltaic power are evaluated. Conversion round-trip efficiency is in the range of 70-80%. Finally, overall system efficiency, which also considers system power consumption, is 8-13 percentage points lower for Primary Control Reserve and the photovoltaic-battery application. However, for Secondary Control Reserve, the total round-trip efficiency is found to be extremely low at 23% due to the low energy throughput of this application type.« less

  1. Technical Quality of Complete Dentures: Influence on Masticatory Efficiency and Quality of Life.

    PubMed

    Tôrres, Ana Clara Soares Paiva; Maciel, Amanda de Queiroz; de Farias, Danielle Bezerra; de Medeiros, Annie Karoline Bezerra; Vieira, Flávia Patrícia Tavares Veras; Carreiro, Adriana da Fonte Porto

    2017-11-09

    To evaluate the effect of the technical quality of conventional complete dentures (CD) on masticatory efficiency and quality of life (QoL) of denture wearers during a 1-year follow-up. A prospective clinical trial with 32 edentulous patients (mean age of 60.2 years) wearing mandibular and maxillary dentures was conducted. All patients were evaluated wearing their preexisting dentures and after 3, 6, and 12 months postinsertion of new dentures. A reproducible method for objective evaluation of the technical quality of CDs was employed. Masticatory efficiency was evaluated by the colorimetric method using beads as artificial testing food. The oral health impact on patient QoL was measured using the OHIP-EDENT (Oral Health Impact Profile in Edentulous Adults) questionnaire. The nonparametric Wilcoxon test was applied to reveal any differences in technical quality between the preexisting and new dentures. The Friedman test was used to detect differences in masticatory efficiency and oral health impact on QoL. Spearman's correlation was applied to reveal correlation between the variables. Comparing preexisting and new dentures, significant improvement was found in technical quality between the dentures (p < 0.001). There was no statistically significant difference in masticatory efficiency. A significant decrease was found in the total OHIP-EDENT scores after denture replacement. A positive correlation was found between technical quality and OHIP in the new denture wearers (p = 0.011). According to the results of this study, denture quality significantly improved patients' oral health-related QoL; however, insertion of new dentures did not influence masticatory efficiency. © 2017 by the American College of Prosthodontists.

  2. Scout: An Impact Analysis Tool for Building Energy-Efficiency Technologies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harris, Chioke; Langevin, Jared; Roth, Amir

    Evaluating the national impacts of candidate U.S. building energy-efficiency technologies has historically been difficult for organizations with large energy efficiency portfolios. In particular, normalizing results from technology-specific impact studies is time-consuming when those studies do not use comparable assumptions about the underlying building stock. To equitably evaluate its technology research, development, and deployment portfolio, the U.S. Department of Energy's Building Technologies Office has developed Scout, a software tool that quantitatively assesses the energy and CO2 impacts of building energy-efficiency measures on the national building stock. Scout efficiency measures improve upon the unit performance and/or lifetime operational costs of an equipmentmore » stock baseline that is determined from the U.S. Energy Information Administration Annual Energy Outlook (AEO). Scout measures are characterized by a market entry and exit year, unit performance level, cost, and lifetime. To evaluate measures on a consistent basis, Scout uses EnergyPlus simulation on prototype building models to translate measure performance specifications to whole-building energy savings; these savings impacts are then extended to a national scale using floor area weighting factors. Scout represents evolution in the building stock over time using AEO projections for new construction, retrofit, and equipment replacements, and competes technologies within market segments under multiple adoption scenarios. Scout and its efficiency measures are open-source, as is the EnergyPlus whole building simulation framework that is used to evaluate measure performance. The program is currently under active development and will be formally released once an initial set of measures has been analyzed and reviewed.« less

  3. Measuring efficiency among US federal hospitals.

    PubMed

    Harrison, Jeffrey P; Meyer, Sean

    2014-01-01

    This study evaluates the efficiency of federal hospitals, specifically those hospitals administered by the US Department of Veterans Affairs and the US Department of Defense. Hospital executives, health care policymakers, taxpayers, and federal hospital beneficiaries benefit from studies that improve hospital efficiency. This study uses data envelopment analysis to evaluate a panel of 165 federal hospitals in 2007 and 157 of the same hospitals again in 2011. Results indicate that overall efficiency in federal hospitals improved from 81% in 2007 to 86% in 2011. The number of federal hospitals operating on the efficiency frontier decreased slightly from 25 in 2007 to 21 in 2011. The higher efficiency score clearly documents that federal hospitals are becoming more efficient in the management of resources. From a policy perspective, this study highlights the economic importance of encouraging increased efficiency throughout the health care industry. This research examines benchmarking strategies to improve the efficiency of hospital services to federal beneficiaries. Through the use of strategies such as integrated information systems, consolidation of services, transaction-cost economics, and focusing on preventative health care, these organizations have been able to provide quality service while maintaining fiscal responsibility. In addition, the research documented the characteristics of those federal hospitals that were found to be on the Efficiency Frontier. These hospitals serve as benchmarks for less efficient federal hospitals as they develop strategies for improvement.

  4. Experimental evaluation of a translating nozzle sidewall radial turbine

    NASA Technical Reports Server (NTRS)

    Roelke, Richard J.; Rogo, Casimir

    1987-01-01

    An experimental performance evaluation was made of two movable sidewall variable area radial turbines. The turbine designs were representative of the gas generator turbine of a variable flow capacity rotorcraft engine. The first turbine was an uncooled design while the second turbine had a cooled nozzle but an uncooled rotor. The cooled nozzle turbine was evaluated both with and without coolant flow. The test results showed that the movable nozzle wall is a viable and efficient means to effectively control the flow capacity of a radial turbine. Peak efficiencies of the second turbine with and without nozzle coolant were 86.5 and 88 percent respectively. These values are comparable to pivoting vane variable geometry turbines; however, the decrease in efficiency as the flow was varied from the design value was much less for the movable wall turbine. Several design improvements which should increase the turbine efficiency one or two more points are identified. These design improvements include reduced leakage losses and relocation of the vane coolant ejection holes to reduce mainstream disturbance.

  5. Evaluation of a Wipe Surface Sample Method for Collection of Bacillus Spores from Nonporous Surfaces▿

    PubMed Central

    Brown, Gary S.; Betty, Rita G.; Brockmann, John E.; Lucero, Daniel A.; Souza, Caroline A.; Walsh, Kathryn S.; Boucher, Raymond M.; Tezak, Mathew; Wilson, Mollye C.; Rudolph, Todd

    2007-01-01

    Polyester-rayon blend wipes were evaluated for efficiency of extraction and recovery of powdered Bacillus atrophaeus spores from stainless steel and painted wallboard surfaces. Method limits of detection were also estimated for both surfaces. The observed mean efficiency of polyester-rayon blend wipe recovery from stainless steel was 0.35 with a standard deviation of ±0.12, and for painted wallboard it was 0.29 with a standard deviation of ±0.15. Evaluation of a sonication extraction method for the polyester-rayon blend wipes produced a mean extraction efficiency of 0.93 with a standard deviation of ±0.09. Wipe recovery quantitative limits of detection were estimated at 90 CFU per unit of stainless steel sample area and 105 CFU per unit of painted wallboard sample area. The method recovery efficiency and limits of detection established in this work provide useful guidance for the planning of incident response environmental sampling following the release of a biological agent such as Bacillus anthracis. PMID:17122390

  6. Evaluation of a wipe surface sample method for collection of Bacillus spores from nonporous surfaces.

    PubMed

    Brown, Gary S; Betty, Rita G; Brockmann, John E; Lucero, Daniel A; Souza, Caroline A; Walsh, Kathryn S; Boucher, Raymond M; Tezak, Mathew; Wilson, Mollye C; Rudolph, Todd

    2007-02-01

    Polyester-rayon blend wipes were evaluated for efficiency of extraction and recovery of powdered Bacillus atrophaeus spores from stainless steel and painted wallboard surfaces. Method limits of detection were also estimated for both surfaces. The observed mean efficiency of polyester-rayon blend wipe recovery from stainless steel was 0.35 with a standard deviation of +/-0.12, and for painted wallboard it was 0.29 with a standard deviation of +/-0.15. Evaluation of a sonication extraction method for the polyester-rayon blend wipes produced a mean extraction efficiency of 0.93 with a standard deviation of +/-0.09. Wipe recovery quantitative limits of detection were estimated at 90 CFU per unit of stainless steel sample area and 105 CFU per unit of painted wallboard sample area. The method recovery efficiency and limits of detection established in this work provide useful guidance for the planning of incident response environmental sampling following the release of a biological agent such as Bacillus anthracis.

  7. A study of the talent training project management for semiconductor industry in Taiwan: the application of a hybrid data envelopment analysis approach.

    PubMed

    Kao, Ling-Jing; Chiu, Shu-Yu; Ko, Hsien-Tang

    2014-01-01

    The purpose of this study is to evaluate the training institution performance and to improve the management of the Manpower Training Project (MTP) administered by the Semiconductor Institute in Taiwan. Much literature assesses the efficiency of an internal training program initiated by a firm, but only little literature studies the efficiency of an external training program led by government. In the study, a hybrid solution of ICA-DEA and ICA-MPI is developed for measuring the efficiency and the productivity growth of each training institution over the period. The technical efficiency change, the technological change, pure technical efficiency change, scale efficiency change, and the total factor productivity change were evaluated according to five inputs and two outputs. According to the results of the study, the training institutions can be classified by their efficiency successfully and the guidelines for the optimal level of input resources can be obtained for each inefficient training institution. The Semiconductor Institute in Taiwan can allocate budget more appropriately and establish withdrawal mechanisms for inefficient training institutions.

  8. A Study of the Talent Training Project Management for Semiconductor Industry in Taiwan: The Application of a Hybrid Data Envelopment Analysis Approach

    PubMed Central

    Kao, Ling-Jing; Chiu, Shu-Yu; Ko, Hsien-Tang

    2014-01-01

    The purpose of this study is to evaluate the training institution performance and to improve the management of the Manpower Training Project (MTP) administered by the Semiconductor Institute in Taiwan. Much literature assesses the efficiency of an internal training program initiated by a firm, but only little literature studies the efficiency of an external training program led by government. In the study, a hybrid solution of ICA-DEA and ICA-MPI is developed for measuring the efficiency and the productivity growth of each training institution over the period. The technical efficiency change, the technological change, pure technical efficiency change, scale efficiency change, and the total factor productivity change were evaluated according to five inputs and two outputs. According to the results of the study, the training institutions can be classified by their efficiency successfully and the guidelines for the optimal level of input resources can be obtained for each inefficient training institution. The Semiconductor Institute in Taiwan can allocate budget more appropriately and establish withdrawal mechanisms for inefficient training institutions. PMID:24977192

  9. Eco-efficiency model for evaluating feedlot rations in the Great Plains, United States

    USDA-ARS?s Scientific Manuscript database

    Environmental impacts attributable to beef feedlot production provide an opportunity for economically-linked environmental efficiency optimization. An adaptable eco-efficiency model was developed to assess the impacts of dietary rations. The hybridized model utilized California Net Energy System m...

  10. 76 FR 47178 - Energy Efficiency Program: Test Procedure for Lighting Systems (Luminaires)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-04

    ...: Test Procedure for Lighting Systems (Luminaires) AGENCY: Office of Energy Efficiency and Renewable... (``DOE'' or the ``Department'') is currently evaluating energy efficiency test procedures for luminaires... products. DOE recognizes that well-designed test procedures are important to produce reliable, repeatable...

  11. Evaluation of species-dependent detection efficiencies in the aerosol mass spectrometer

    USDA-ARS?s Scientific Manuscript database

    Mass concentrations of chemical species calculated from the aerosol mass spectrometer (AMS) depend on two factors: particle collection efficiency (CE) and relative ionization efficiency (RIE, relative to the primary calibrant ammonium nitrate). While previous studies have characterized CE, RIE is re...

  12. Data envelopment analysis with upper bound on output to measure efficiency performance of departments in Malaikulsaleh University

    NASA Astrophysics Data System (ADS)

    Abdullah, Dahlan; Suwilo, Saib; Tulus; Mawengkang, Herman; Efendi, Syahril

    2017-09-01

    The higher education system in Indonesia can be considered not only as an important source of developing knowledge in the country, but also could create positive living conditions for the country. Therefore it is not surprising that enrollments in higher education continue to expand. However, the implication of this situation, the Indonesian government is necessarily to support more funds. In the interest of accountability, it is essential to measure the efficiency for this higher institution. Data envelopment analysis (DEA) is a method to evaluate the technical efficiency of production units which have multiple input and output. The higher learning institution considered in this paper is Malikussaleh University located in Lhokseumawe, a city in Aceh province of Indonesia. This paper develops a method to evaluate efficiency for all departments in Malikussaleh University using DEA with bounded output. Accordingly, we present some important differences in efficiency of those departments. Finally we discuss the effort should be done by these departments in order to become efficient.

  13. Efficient Testing Combining Design of Experiment and Learn-to-Fly Strategies

    NASA Technical Reports Server (NTRS)

    Murphy, Patrick C.; Brandon, Jay M.

    2017-01-01

    Rapid modeling and efficient testing methods are important in a number of aerospace applications. In this study efficient testing strategies were evaluated in a wind tunnel test environment and combined to suggest a promising approach for both ground-based and flight-based experiments. Benefits of using Design of Experiment techniques, well established in scientific, military, and manufacturing applications are evaluated in combination with newly developing methods for global nonlinear modeling. The nonlinear modeling methods, referred to as Learn-to-Fly methods, utilize fuzzy logic and multivariate orthogonal function techniques that have been successfully demonstrated in flight test. The blended approach presented has a focus on experiment design and identifies a sequential testing process with clearly defined completion metrics that produce increased testing efficiency.

  14. Autonomous Dirigible Airships: A Comparative Analysis and Operational Efficiency Evaluation for Logistical Use in Complex Environments

    DTIC Science & Technology

    2012-06-01

    NAVAL POSTGRADUATE SCHOOL MONTEREY, CALIFORNIA MBA PROFESSIONAL REPORT Autonomous Dirigible Airships: A Comparative Analysis...COVERED MBA Professional Report 4. TITLE AND SUBTITLE: Autonomous Dirigible Airships: A Comparative Analysis and Operational Efficiency Evaluation...NAME(S) AND ADDRESS(ES) N/ A 10. SPONSORING / MONITORING AGENCY REPORT NUMBER 11. SUPPLEMENTARY NOTES The views expressed in this report are

  15. An Econometric Approach to Evaluate Navy Advertising Efficiency.

    DTIC Science & Technology

    1996-03-01

    This thesis uses an econometric approach to systematically and comprehensively analyze Navy advertising and recruiting data to determine Navy... advertising cost efficiency in the Navy recruiting process. Current recruiting and advertising cost data are merged into an appropriate data base and...evaluated using multiple regression techniques to find assessments of the relationships between Navy advertising expenditures and recruit contracts attained

  16. OZONE PRODUCTION EFFICIENCY AND NOX DEPLETION IN AN URBAN PLUME: INTERPRETATION OF FIELD OBSERVATIONS AND IMPLICATIONS FOR EVALUATING O3-NOX-VOC SENSITIVITY

    EPA Science Inventory

    Ozone production efficiency (OPE) can be defined as the number of ozone (O3) molecules photochemically produced by a molecule of NOx (NO + NO2) before it is lost from the NOx - O3 cycle. Here, we consider observational and modeling techniques to evaluate various operational defi...

  17. Improving the Effectiveness and Efficiency of Teaching Large Classes: Development and Evaluation of a Novel e-Resource in Cancer Biology

    ERIC Educational Resources Information Center

    Hejmadi, Momna V.

    2007-01-01

    This paper describes the development and evaluation of a blended learning resource in the biosciences, created by combining online learning with formal face-face lectures and supported by formative assessments. In order to improve the effectiveness and efficiency of teaching large classes with mixed student cohorts, teaching was delivered through…

  18. Evaluation energy efficiency of bioconversion knot rejects to ethanol in comparison to other thermochemically pretreated biomass

    Treesearch

    Zhaojiang Wang; Menghua Qin; J.Y. Zhu; Guoyu Tian; Zongquan Li

    2013-01-01

    Rejects from sulfite pulp mill that otherwise would be disposed of by incineration were converted to ethanol by a combined physical–biological process that was comprised of physical refining and simultaneous saccharification and fermentation (SSF). The energy efficiency was evaluated with comparison to thermochemically pretreated biomass, such as those pretreated by...

  19. DEVELOPMENT OF AN ARMY STATIONARY AXLE TEST STAND FOR LUBRICANT EFFICIENCY EVALUATION-PART II

    DTIC Science & Technology

    2017-01-13

    value was estimated based on the engines maximum peak torque output, multiplied by the transmissions 1st gear ratio, high range transfer case ratio...efficiency test stand to allow for laboratory based investigation of Fuel Efficient Gear Oils (FEGO) and their impact on vehicle efficiency. Development...their impact on vehicle efficiency. The test stand was designed and developed with the following goals: • Provide a lower cost alternative for

  20. Policy evaluation for a bus-based transit system: the case study of Busan, Korea

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lew, K.S.

    This study considers a quite specific set of dimensions of transit evaluation as a comprehensive management-strategy approach for addressing the ongoing problems of urban public transit systems and apply them in a case study. With increasing difficulties in providing effective public transportation, attention in this study was placed on providing for the movement of people in an efficient and equitable manner. This study was therefore concerned with just identifying and evaluating policy options that are feasible within the socio-economic and political context of the Busan metropolitan area and, in particular, how the criteria of efficiency and equity can best bemore » achieved by implementing transit policy alternatives. In the absence of long-run major public investment in urban transportation, the criteria of both efficiency and equity can only be furthered through managerial strategies applied within a systematic evaluative framework. By emphasizing the planning, operational, and managerial considerations of fixed-route bus transit in Busan, it has been acknowledged that efficient and equitable public transportation can be provided through a variety of social, economic, political, and institutional arrangements that are possible to apply from a policy viewpoint in the immediate future.« less

  1. High efficiency, long life terrestrial solar panel

    NASA Technical Reports Server (NTRS)

    Chao, T.; Khemthong, S.; Ling, R.; Olah, S.

    1977-01-01

    The design of a high efficiency, long life terrestrial module was completed. It utilized 256 rectangular, high efficiency solar cells to achieve high packing density and electrical output. Tooling for the fabrication of solar cells was in house and evaluation of the cell performance was begun. Based on the power output analysis, the goal of a 13% efficiency module was achievable.

  2. High-efficiency silicon solar-cell design and practical barriers

    NASA Technical Reports Server (NTRS)

    Mokashi, A.

    1985-01-01

    A numerical evaluation technique is used to study the impact of practical barriers, such as heavy doping effects (Auger recombination, band gap narrowing), surface recombination, shadowing losses and minority-carrier lifetime (Tau), on a high efficiency silicon solar cell performance. Considering a high Tau of 1 ms, efficiency of a silicon solar cell of the hypothetical case is estimated to be around 29%. This is comparable with (detailed balance limit) maximum efficiency of a p-n junction solar cell of 30%. Value of Tau is varied from 1 second to 20 micro. Heavy doping effects, and realizable values of surface recombination velocities and shadowing, are then considered in succession and their influence on cell efficiency is evaluated and quantified. These practical barriers cause the cell efficiency to reduce from the maximum value of 29% to the experimentally achieved value of about 19%. Improvement in open circuit voltage V sub oc is required to achieve cell efficiency greater than 20%. Increased value of Tau reduces reverse saturation current and, hence, improves V sub oc. Control of surface recombination losses becomes critical at higher V sub oc. Substantial improvement in Tau and considerable reduction in surface recombination velocities is essential to achieve cell efficiencies greater than 20%.

  3. The dependence of efficiency of transmembrane molecular transfer using electroporation on medium viscosity.

    PubMed

    Sungailaitė, Sandra; Ruzgys, Paulius; Šatkauskienė, Ingrida; Čepurnienė, Karolina; Šatkauskas, Saulius

    2015-01-01

    In the present study, we aimed to evaluate the efficiency of drug and gene electrotransfer into cells in vitro depending on medium viscosity. Experiments were performed using Chinese hamster ovary cells. Efficiency of molecular electrotransfer depending of medium viscosity was evaluated using two different electroporation conditions: a high-voltage (HV) pulse and a combination of a high-voltage pulse and a low-voltage pulse (HV + LV). To evaluate the efficiency of molecular electrotransfer, anticancer drug bleomycin and two different plasmids coding for green fluorescent protein and luciferase were used. We found that a slight increase in medium viscosity from 1.3-1.4 mPa·s significantly decreased the transfection efficiency, both in terms of transfected cells and total protein production, which was abolished completely with an increase in medium viscosity to 6.1 mPa·s. Notably, at this medium viscosity, electrotransfer of the small anticancer drug was still efficient. Using HV and HV + LV pulse combinations, we showed that a decrease of DNA electrotransfer, especially at lower medium viscosities, can be compensated for by the LV pulse to some extent. On the other hand, the addition of the LV pulse after the HV pulse did not have any positive effect on the efficiency of bleomycin electrotransfer. These findings demonstrate that transfection is very susceptible to medium viscosity and highlights the importance of the electrophoretic component in experiments when a considerable transfection level is needed. Copyright © 2015 John Wiley & Sons, Ltd.

  4. Hong Kong Hospital Authority resource efficiency evaluation: Via a novel DEA-Malmquist model and Tobit regression model.

    PubMed

    Guo, Hainan; Zhao, Yang; Niu, Tie; Tsui, Kwok-Leung

    2017-01-01

    The Hospital Authority (HA) is a statutory body managing all the public hospitals and institutes in Hong Kong (HK). In recent decades, Hong Kong Hospital Authority (HKHA) has been making efforts to improve the healthcare services, but there still exist some problems like unfair resource allocation and poor management, as reported by the Hong Kong medical legislative committee. One critical consequence of these problems is low healthcare efficiency of hospitals, leading to low satisfaction among patients. Moreover, HKHA also suffers from the conflict between limited resource and growing demand. An effective evaluation of HA is important for resource planning and healthcare decision making. In this paper, we propose a two-phase method to evaluate HA efficiency for reducing healthcare expenditure and improving healthcare service. Specifically, in Phase I, we measure the HKHA efficiency changes from 2000 to 2013 by applying a novel DEA-Malmquist index with undesirable factors. In Phase II, we further explore the impact of some exogenous factors (e.g., population density) on HKHA efficiency by Tobit regression model. Empirical results show that there are significant differences between the efficiencies of different hospitals and clusters. In particular, it is found that the public hospital serving in a richer district has a relatively lower efficiency. To a certain extent, this reflects the socioeconomic reality in HK that people with better economic condition prefers receiving higher quality service from the private hospitals.

  5. Hong Kong Hospital Authority resource efficiency evaluation: Via a novel DEA-Malmquist model and Tobit regression model

    PubMed Central

    Guo, Hainan; Zhao, Yang; Niu, Tie; Tsui, Kwok-Leung

    2017-01-01

    The Hospital Authority (HA) is a statutory body managing all the public hospitals and institutes in Hong Kong (HK). In recent decades, Hong Kong Hospital Authority (HKHA) has been making efforts to improve the healthcare services, but there still exist some problems like unfair resource allocation and poor management, as reported by the Hong Kong medical legislative committee. One critical consequence of these problems is low healthcare efficiency of hospitals, leading to low satisfaction among patients. Moreover, HKHA also suffers from the conflict between limited resource and growing demand. An effective evaluation of HA is important for resource planning and healthcare decision making. In this paper, we propose a two-phase method to evaluate HA efficiency for reducing healthcare expenditure and improving healthcare service. Specifically, in Phase I, we measure the HKHA efficiency changes from 2000 to 2013 by applying a novel DEA-Malmquist index with undesirable factors. In Phase II, we further explore the impact of some exogenous factors (e.g., population density) on HKHA efficiency by Tobit regression model. Empirical results show that there are significant differences between the efficiencies of different hospitals and clusters. In particular, it is found that the public hospital serving in a richer district has a relatively lower efficiency. To a certain extent, this reflects the socioeconomic reality in HK that people with better economic condition prefers receiving higher quality service from the private hospitals. PMID:28886087

  6. Heating efficiency evaluation with mimicking plasma conditions of integrated fast-ignition experiment.

    PubMed

    Fujioka, Shinsuke; Johzaki, Tomoyuki; Arikawa, Yasunobu; Zhang, Zhe; Morace, Alessio; Ikenouchi, Takahito; Ozaki, Tetsuo; Nagai, Takahiro; Abe, Yuki; Kojima, Sadaoki; Sakata, Shohei; Inoue, Hiroaki; Utsugi, Masaru; Hattori, Shoji; Hosoda, Tatsuya; Lee, Seung Ho; Shigemori, Keisuke; Hironaka, Youichiro; Sunahara, Atsushi; Sakagami, Hitoshi; Mima, Kunioki; Fujimoto, Yasushi; Yamanoi, Kohei; Norimatsu, Takayoshi; Tokita, Shigeki; Nakata, Yoshiki; Kawanaka, Junji; Jitsuno, Takahisa; Miyanaga, Noriaki; Nakai, Mitsuo; Nishimura, Hiroaki; Shiraga, Hiroyuki; Nagatomo, Hideo; Azechi, Hiroshi

    2015-06-01

    A series of experiments were carried out to evaluate the energy-coupling efficiency from heating laser to a fuel core in the fast-ignition scheme of laser-driven inertial confinement fusion. Although the efficiency is determined by a wide variety of complex physics, from intense laser plasma interactions to the properties of high-energy density plasmas and the transport of relativistic electron beams (REB), here we simplify the physics by breaking down the efficiency into three measurable parameters: (i) energy conversion ratio from laser to REB, (ii) probability of collision between the REB and the fusion fuel core, and (iii) fraction of energy deposited in the fuel core from the REB. These three parameters were measured with the newly developed experimental platform designed for mimicking the plasma conditions of a realistic integrated fast-ignition experiment. The experimental results indicate that the high-energy tail of REB must be suppressed to heat the fuel core efficiently.

  7. Evaluation of Signal Regeneration Impact on the Power Efficiency of Long-Haul DWDM Systems

    NASA Astrophysics Data System (ADS)

    Pavlovs, D.; Bobrovs, V.; Parfjonovs, M.; Alsevska, A.; Ivanovs, G.

    2017-10-01

    Due to potential economic benefits and expected environmental impact, the power consumption issue in wired networks has become a major challenge. Furthermore, continuously increasing global Internet traffic demands high spectral efficiency values. As a result, the relationship between spectral efficiency and energy consumption of telecommunication networks has become a popular topic of academic research over the past years, where a critical parameter is power efficiency. The present research contains calculation results that can be used by optical network designers and operators as guidance for developing more power efficient communication networks if the planned system falls within the scope of this paper. The research results are presented as average aggregated traffic curves that provide more flexible data for the systems with different spectrum availability. Further investigations could be needed in order to evaluate the parameters under consideration taking into account particular spectral parameters, e.g., the entire C-band.

  8. Radiative efficiency of lead iodide based perovskite solar cells

    PubMed Central

    Tvingstedt, Kristofer; Malinkiewicz, Olga; Baumann, Andreas; Deibel, Carsten; Snaith, Henry J.; Dyakonov, Vladimir; Bolink, Henk J.

    2014-01-01

    The maximum efficiency of any solar cell can be evaluated in terms of its corresponding ability to emit light. We herein determine the important figure of merit of radiative efficiency for Methylammonium Lead Iodide perovskite solar cells and, to put in context, relate it to an organic photovoltaic (OPV) model device. We evaluate the reciprocity relation between electroluminescence and photovoltaic quantum efficiency and conclude that the emission from the perovskite devices is dominated by a sharp band-to-band transition that has a radiative efficiency much higher than that of an average OPV device. As a consequence, the perovskite have the benefit of retaining an open circuit voltage ~0.14 V closer to its radiative limit than the OPV cell. Additionally, and in contrast to OPVs, we show that the photoluminescence of the perovskite solar cell is substantially quenched under short circuit conditions in accordance with how an ideal photovoltaic cell should operate. PMID:25317958

  9. A mixed integer bi-level DEA model for bank branch performance evaluation by Stackelberg approach

    NASA Astrophysics Data System (ADS)

    Shafiee, Morteza; Lotfi, Farhad Hosseinzadeh; Saleh, Hilda; Ghaderi, Mehdi

    2016-03-01

    One of the most complicated decision making problems for managers is the evaluation of bank performance, which involves various criteria. There are many studies about bank efficiency evaluation by network DEA in the literature review. These studies do not focus on multi-level network. Wu (Eur J Oper Res 207:856-864, 2010) proposed a bi-level structure for cost efficiency at the first time. In this model, multi-level programming and cost efficiency were used. He used a nonlinear programming to solve the model. In this paper, we have focused on multi-level structure and proposed a bi-level DEA model. We then used a liner programming to solve our model. In other hand, we significantly improved the way to achieve the optimum solution in comparison with the work by Wu (2010) by converting the NP-hard nonlinear programing into a mixed integer linear programming. This study uses a bi-level programming data envelopment analysis model that embodies internal structure with Stackelberg-game relationships to evaluate the performance of banking chain. The perspective of decentralized decisions is taken in this paper to cope with complex interactions in banking chain. The results derived from bi-level programming DEA can provide valuable insights and detailed information for managers to help them evaluate the performance of the banking chain as a whole using Stackelberg-game relationships. Finally, this model was applied in the Iranian bank to evaluate cost efficiency.

  10. Designing workload analysis questionnaire to evaluate needs of employees

    NASA Astrophysics Data System (ADS)

    Astuti, Rahmaniyah Dwi; Navi, Muhammad Abdu Haq

    2018-02-01

    Incompatibility between workload with work capacity is one of main problem to make optimal result. In case at the office, there are constraints to determine workload because of non-repetitive works. Employees do work based on the targets set in a working period. At the end of the period is usually performed an evaluation of employees performance to evaluate needs of employees. The aims of this study to design a workload questionnaire tools to evaluate the efficiency level of position as indicator to determine needs of employees based on the Indonesian State Employment Agency Regulation on workload analysis. This research is applied to State-Owned Enterprise PT. X by determining 3 positions as a pilot project. Position A is held by 2 employees, position B is held by 7 employees, and position C is held by 6 employees. From the calculation result, position A has an efficiency level of 1,33 or "very good", position B has an efficiency level of 1.71 or "enough", and position C has an efficiency level of 1.03 or "very good". The application of this tools giving suggestion the needs of employees of position A is 3 people, position B is 5 people, and position C is 6 people. The difference between the number of employees and the calculation result is then analyzed by interviewing the employees to get more data about personal perception. It can be concluded that this workload evaluation tools can be used as an alternative solution to evaluate needs of employees in office.

  11. Electrosprayed chitosan nanoparticles: facile and efficient approach for bacterial transformation

    NASA Astrophysics Data System (ADS)

    Abyadeh, Morteza; Sadroddiny, Esmaeil; Ebrahimi, Ammar; Esmaeili, Fariba; Landi, Farzaneh Saeedi; Amani, Amir

    2017-12-01

    A rapid and efficient procedure for DNA transformation is a key prerequisite for successful cloning and genomic studies. While there are efforts to develop a facile method, so far obtained efficiencies for alternative methods have been unsatisfactory (i.e. 105-106 CFU/μg plasmid) compared with conventional method (up to 108 CFU/μg plasmid). In this work, for the first time, we prepared chitosan/pDNA nanoparticles by electrospraying methods to improve transformation process. Electrospray method was used for chitosan/pDNA nanoparticles production to investigate the non-competent bacterial transformation efficiency; besides, the effect of chitosan molecular weight, N/P ratio and nanoparticle size on non-competent bacterial transformation efficiency was evaluated too. The results showed that transformation efficiency increased with decreasing the molecular weight, N/P ratio and nanoparticles size. In addition, transformation efficiency of 1.7 × 108 CFU/μg plasmid was obtained with chitosan molecular weight, N/P ratio and nanoparticles size values of 30 kDa, 1 and 125 nm. Chitosan/pDNA electrosprayed nanoparticles were produced and the effect of molecular weight, N/P and size of nanoparticles on transformation efficiency was evaluated. In total, we present a facile and rapid method for bacterial transformation, which has comparable efficiency with the common method.

  12. Effect of transverse nonuniformity of the rf field on the efficiency of microwave sources driven by linear electron beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nusinovich, G.S.; Sinitsyn, O.V.

    This paper contains a simple analytical theory that allows one to evaluate the effect of transverse nonuniformity of the rf field on the interaction efficiency in various microwave sources driven by linear electron beams. The theory is, first, applied to the systems where the beams of cylindrical symmetry interact with rf fields of microwave circuits having Cartesian geometry. Also, various kinds of microwave devices driven by sheet electron beams (orotrons, clinotrons) are considered. The theory can be used for evaluating the efficiency of novel sources of coherent terahertz radiation.

  13. Photodetectors for scintillator proportionality measurement

    NASA Astrophysics Data System (ADS)

    Moses, William W.; Choong, Woon-Seng; Hull, Giulia; Payne, Steve; Cherepy, Nerine; Valentine, John D.

    2009-10-01

    We evaluate photodetectors for use in a Compton Coincidence apparatus designed for measuring scintillator proportionality. There are many requirements placed on the photodetector in these systems, including active area, linearity, and the ability to accurately measure low light levels (which implies high quantum efficiency and high signal-to-noise ratio). Through a combination of measurement and Monte Carlo simulation, we evaluate a number of potential photodetectors, especially photomultiplier tubes and hybrid photodetectors. Of these, we find that the most promising devices available are photomultiplier tubes with high (˜50%) quantum efficiency, although hybrid photodetectors with high quantum efficiency would be preferable.

  14. Experimental evaluation of exhaust mixers for an Energy Efficient Engine

    NASA Technical Reports Server (NTRS)

    Kozlowski, H.; Kraft, G.

    1980-01-01

    Static scale model tests were conducted to evaluate exhaust system mixers for a high bypass ratio engine as part of the NASA sponsored Energy Efficient program. Gross thrust coefficients were measured for a series of mixer configurations which included variations in the number of mixer lobes, tailpipe length, mixer penetration, and length. All of these parameters have a significant impact on exhaust system performance. In addition, flow visualization pictures and pressure/temperature traverses were obtained for selected configurations. Parametric performance trends are discussed and the results considered relative to the Energy Efficient Engine program goals.

  15. Quasi-optical grids with thin rectangular patch/aperture elements

    NASA Technical Reports Server (NTRS)

    Wu, Te-Kao

    1993-01-01

    Theoretical analysis is presented for an efficient and accurate performance evaluation of quasi-optical grids comprised of thin rectangular patch/aperture elements with/without a dielectric substrate/superstrate. The convergence rate of this efficient technique is improved by an order of magnitude with the approximate edge conditions incorporated in the basis functions of the integral equation solution. Also presented are the interesting applications of this efficient analytical technique to the design and performance evaluation of the coupling grids and beam splitters in the optical systems as well as thermal protection sunshields used in the communication systems of satellites and spacecrafts.

  16. Institute for Atom-Efficient Chemical Transformations Energy Frontier

    Science.gov Websites

    Synthesis Search Argonne ... Search Argonne Home > Institute for Atom-Efficient Chemical Transformations Synthesis Characterization Computational Studies Evaluation and Mechanisms/Catalytic Experimentation Using

  17. Operational and environmental performance in China's thermal power industry: Taking an effectiveness measure as complement to an efficiency measure.

    PubMed

    Wang, Ke; Zhang, Jieming; Wei, Yi-Ming

    2017-05-01

    The trend toward a more fiercely competitive and strictly environmentally regulated electricity market in several countries, including China has led to efforts by both industry and government to develop advanced performance evaluation models that adapt to new evaluation requirements. Traditional operational and environmental efficiency measures do not fully consider the influence of market competition and environmental regulations and, thus, are not sufficient for the thermal power industry to evaluate its operational performance with respect to specific marketing goals (operational effectiveness) and its environmental performance with respect to specific emissions reduction targets (environmental effectiveness). As a complement to an operational efficiency measure, an operational effectiveness measure not only reflects the capacity of an electricity production system to increase its electricity generation through the improvement of operational efficiency, but it also reflects the system's capability to adjust its electricity generation activities to match electricity demand. In addition, as a complement to an environmental efficiency measure, an environmental effectiveness measure not only reflects the capacity of an electricity production system to decrease its pollutant emissions through the improvement of environmental efficiency, but it also reflects the system's capability to adjust its emissions abatement activities to fulfill environmental regulations. Furthermore, an environmental effectiveness measure helps the government regulator to verify the rationality of its emissions reduction targets assigned to the thermal power industry. Several newly developed effectiveness measurements based on data envelopment analysis (DEA) were utilized in this study to evaluate the operational and environmental performance of the thermal power industry in China during 2006-2013. Both efficiency and effectiveness were evaluated from the three perspectives of operational, environmental, and joint adjustments to each electricity production system. The operational and environmental performance changes over time were also captured through an effectiveness measure based on the global Malmquist productivity index. Our empirical results indicated that the performance of China's thermal power industry experienced significant progress during the study period and that policies regarding the development and regulation of the thermal power industry yielded the expected effects. However, the emissions reduction targets assigned to China's thermal power industry are loose and conservative. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Voluntary Medical Male Circumcision Scale-Up in Nyanza, Kenya: Evaluating Technical Efficiency and Productivity of Service Delivery

    PubMed Central

    Omondi Aduda, Dickens S.; Ouma, Collins; Onyango, Rosebella; Onyango, Mathews; Bertrand, Jane

    2015-01-01

    Background Voluntary medical male circumcision (VMMC) service delivery is complex and resource-intensive. In Kenya’s context there is still paucity of information on resource use vis-à-vis outputs as programs scale up. Knowledge of technical efficiency, productivity and potential sources of constraints is desirable to improve decision-making. Objective To evaluate technical efficiency and productivity of VMMC service delivery in Nyanza in 2011/2012 using data envelopment analysis. Design Comparative process evaluation of facilities providing VMMC in Nyanza in 2011/2012 using output orientated data envelopment analysis. Results Twenty one facilities were evaluated. Only 1 of 7 variables considered (total elapsed operation time) significantly improved from 32.8 minutes (SD 8.8) in 2011 to 30 minutes (SD 6.6) in 2012 (95%CI = 0.0350–5.2488; p = 0.047). Mean scale technical efficiency significantly improved from 91% (SD 19.8) in 2011 to 99% (SD 4.0) in 2012 particularly among outreach compared to fixed service delivery facilities (CI -31.47959–4.698508; p = 0.005). Increase in mean VRS technical efficiency from 84% (SD 25.3) in 2011 and 89% (SD 25.1) in 2012 was not statistically significant. Benchmark facilities were #119 and #125 in 2011 and #103 in 2012. Malmquist Productivity Index (MPI) at fixed facilities declined by 2.5% but gained by 4.9% at outreach ones by 2012. Total factor productivity improved by 83% (p = 0.032) in 2012, largely due to progress in technological efficiency by 79% (p = 0.008). Conclusions Significant improvement in scale technical efficiency among outreach facilities in 2012 was attributable to accelerated activities. However, ongoing pure technical inefficiency requires concerted attention. Technological progress was the key driver of service productivity growth in Nyanza. Incorporating service-quality dimensions and using stepwise-multiple criteria in performance evaluation enhances comprehensiveness and validity. These findings highlight site-level resource use and sources of variations in VMMC service productivity, which are important for program planning. PMID:25706119

  19. Building Energy Asset Score for Utilities and Energy Efficiency Program Administrators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Building Technologies Office

    2015-01-01

    The Building Energy Asset Score is a national standardized tool for evaluating the physical and structural energy efficiency of commercial and multifamily residential buildings. The Asset Score generates a simple energy efficiency rating that enables comparison among buildings, and identifies opportunities for users to invest in energy efficiency upgrades. It is web-based and free to use. This fact sheet discusses the value of the score for utilities and energy efficiency program administrators.

  20. Motor efficiency: compare apples to apples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keinz, J.R.

    1982-08-01

    The efficiency differences between electric motors are now a significant cost consideration for many companies, but evaluating motor efficiency is not as straightforward as it should be. The buyer must look beyond the manufacturer's designated efficiency, which is too generalized, and the results of independent tests, which vary because of the difficulty in establishing standard conditions. Manufacturers may be following established testing procedures, but not labeling in accordance with the standards. Manufacturers should also supply efficiency versus load-curve data. (DCK)

  1. Self Evaluation of Organizations.

    ERIC Educational Resources Information Center

    Pooley, Richard C.

    Evaluation within human service organizations is defined in terms of accepted evaluation criteria, with reasonable expectations shown and structured into a model of systematic evaluation practice. The evaluation criteria of program effort, performance, adequacy, efficiency and process mechanisms are discussed, along with measurement information…

  2. Evaluation of the Brownfields Program

    EPA Pesticide Factsheets

    The Evaluation of 2003-2008 Brownfields Assessment, Revolving Loan Fund, and Cleanup Grants is the first national program evaluation of the outcomes, efficiencies, and economic benefits produced by Brownfields grants.

  3. Analysis of electric power industry restructuring

    NASA Astrophysics Data System (ADS)

    Al-Agtash, Salem Yahya

    1998-10-01

    This thesis evaluates alternative structures of the electric power industry in a competitive environment. One structure is based on the principle of creating a mandatory power pool to foster competition and manage system economics. The structure is PoolCo (pool coordination). A second structure is based on the principle of allowing independent multilateral trading and decentralized market coordination. The structure is DecCo (decentralized coordination). The criteria I use to evaluate these two structures are: economic efficiency, system reliability and freedom of choice. Economic efficiency evaluation considers strategic behavior of individual generators as well as behavioral variations of different classes of consumers. A supply-function equilibria model is characterized for deriving bidding strategies of competing generators under PoolCo. It is shown that asymmetric equilibria can exist within the capacities of generators. An augmented Lagrangian approach is introduced to solve iteratively for global optimal operations schedules. Under DecCo, the process involves solving iteratively for system operations schedules. The schedules reflect generators strategic behavior and brokers' interactions for arranging profitable trades, allocating losses and managing network congestion. In the determination of PoolCo and DecCo operations schedules, overall costs of power generation (start-up and shut-down costs and availability of hydro electric power) as well as losses and costs of transmission network are considered. For system reliability evaluation, I examine the effect of PoolCo and DecCo operating conditions on the system security. Random component failure perturbations are generated to simulate the actual system behavior. This is done using Monte Carlo simulation. Freedom of choice evaluation accounts for schemes' beneficial opportunities and capabilities to respond to consumers expressed preferences. An IEEE 24-bus test system is used to illustrate the concepts developed for economic efficiency evaluation. The system was tested over two years time period. The results indicate 2.6684 and 2.7269 percent of efficiency loss on average for PoolCo and DecCo, respectively. These values, however, do not represent forecasts of efficiency losses of PoolCo- and DecCo-based competitive industries. Rather, they are illustrations of the efficiency losses for the given IEEE test system and based on the modeling assumptions underlying framework development.

  4. Model-centric distribution automation: Capacity, reliability, and efficiency

    DOE PAGES

    Onen, Ahmet; Jung, Jaesung; Dilek, Murat; ...

    2016-02-26

    A series of analyses along with field validations that evaluate efficiency, reliability, and capacity improvements of model-centric distribution automation are presented. With model-centric distribution automation, the same model is used from design to real-time control calculations. A 14-feeder system with 7 substations is considered. The analyses involve hourly time-varying loads and annual load growth factors. Phase balancing and capacitor redesign modifications are used to better prepare the system for distribution automation, where the designs are performed considering time-varying loads. Coordinated control of load tap changing transformers, line regulators, and switched capacitor banks is considered. In evaluating distribution automation versus traditionalmore » system design and operation, quasi-steady-state power flow analysis is used. In evaluating distribution automation performance for substation transformer failures, reconfiguration for restoration analysis is performed. In evaluating distribution automation for storm conditions, Monte Carlo simulations coupled with reconfiguration for restoration calculations are used. As a result, the evaluations demonstrate that model-centric distribution automation has positive effects on system efficiency, capacity, and reliability.« less

  5. Model-centric distribution automation: Capacity, reliability, and efficiency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Onen, Ahmet; Jung, Jaesung; Dilek, Murat

    A series of analyses along with field validations that evaluate efficiency, reliability, and capacity improvements of model-centric distribution automation are presented. With model-centric distribution automation, the same model is used from design to real-time control calculations. A 14-feeder system with 7 substations is considered. The analyses involve hourly time-varying loads and annual load growth factors. Phase balancing and capacitor redesign modifications are used to better prepare the system for distribution automation, where the designs are performed considering time-varying loads. Coordinated control of load tap changing transformers, line regulators, and switched capacitor banks is considered. In evaluating distribution automation versus traditionalmore » system design and operation, quasi-steady-state power flow analysis is used. In evaluating distribution automation performance for substation transformer failures, reconfiguration for restoration analysis is performed. In evaluating distribution automation for storm conditions, Monte Carlo simulations coupled with reconfiguration for restoration calculations are used. As a result, the evaluations demonstrate that model-centric distribution automation has positive effects on system efficiency, capacity, and reliability.« less

  6. Chapter 2: Commercial and Industrial Lighting Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurnik, Charles W; Gowans, Dakers; Telarico, Chad

    The Commercial and Industrial Lighting Evaluation Protocol (the protocol) describes methods to account for gross energy savings resulting from the programmatic installation of efficient lighting equipment in large populations of commercial, industrial, and other nonresidential facilities. This protocol does not address savings resulting from changes in codes and standards, or from education and training activities. A separate Uniform Methods Project (UMP) protocol, Chapter 3: Commercial and Industrial Lighting Controls Evaluation Protocol, addresses methods for evaluating savings resulting from lighting control measures such as adding time clocks, tuning energy management system commands, and adding occupancy sensors.

  7. An Evaluation of Organization Effectiveness: A Longitudinal Investigation of the Effects of Survey Feedback as an Action Research Intervention on Unit Efficiency, Employee Affective Response, Intergroup Relations and Supervisory Consideration in the U.S. Army

    DTIC Science & Technology

    1977-12-01

    Effects of Survey Feedback as an Action Research Jan. 1977- Dec. 1977 Intervention on Unit Efficiency, Employee Afecti-0’ PERFORMINI ORG. REPORT NUMBER R...INTERVENTION, SATISFACTION, OREANIZATION, EFFECTIVENESS, CONSULTATION, EVALUATION RESEARCH 20. ABSTRACT (Continue on reverse side It necessary and identify...by block number) A six month action research project designed to evaluate the effects of survey feedback u:;edl as an intervention strategy wittin

  8. [Quality level assessment of lowly efficient Tamarix chinensis secondary shrubs in Laizhou Bay of Yellow River Delta].

    PubMed

    Xia, Jiang-Bao; Liu, Yu-Ting; Zhu, Jin-Fang; Xu, Jing-Wei; Lu, Zhao-Hua; Liu, Jing-Tao; Liu, Qing

    2013-06-01

    Taking the Tamarix chinensis secondary shrubs in Laizhou Bay of Yellow River Delta as test objects, and by using synthetic factor method, this paper studied the main factors causing the lowly efficiency of T. chinensis secondary shrubs as well as the main parameters for the classification of lowly efficient T. chinensis secondary shrubs. A total of 24 indices including shrubs growth and soil physical and chemical properties were selected to determine the main affecting factors and parameters in evaluating and classifying the lowly efficient shrubs. There were no obvious correlations between the indices reflecting the shrubs growth and soil quality, and thus, only using shrub growth index to reflect the lowly efficiency level of T. chinensis was not enough, and it would be necessary to combine with soil quality factors to make a comprehensive evaluation. The principal factors reflecting the quality level of lowly efficient T. chinensis shrubs included soil salt content and moisture content, stand age, single tree's aboveground stem, leaf biomass, and basal diameter, followed by soil density, porosity, and soil nutrient status. The lowly efficient T. chinensis shrubs in the Bay could be classified into five types, namely, shrub with growth potential, slightly low quality shrub, moderately lowly efficient shrub, moderately low quality and lowly efficient shrub, and seriously low quality and lowly efficient shrub. The main features, low efficiency causes, and management measures of these shrubs were discussed based on the mean cluster value.

  9. Field evaluation of personal sampling methods for multiple bioaerosols.

    PubMed

    Wang, Chi-Hsun; Chen, Bean T; Han, Bor-Cheng; Liu, Andrew Chi-Yeu; Hung, Po-Chen; Chen, Chih-Yong; Chao, Hsing Jasmine

    2015-01-01

    Ambient bioaerosols are ubiquitous in the daily environment and can affect health in various ways. However, few studies have been conducted to comprehensively evaluate personal bioaerosol exposure in occupational and indoor environments because of the complex composition of bioaerosols and the lack of standardized sampling/analysis methods. We conducted a study to determine the most efficient collection/analysis method for the personal exposure assessment of multiple bioaerosols. The sampling efficiencies of three filters and four samplers were compared. According to our results, polycarbonate (PC) filters had the highest relative efficiency, particularly for bacteria. Side-by-side sampling was conducted to evaluate the three filter samplers (with PC filters) and the NIOSH Personal Bioaerosol Cyclone Sampler. According to the results, the Button Aerosol Sampler and the IOM Inhalable Dust Sampler had the highest relative efficiencies for fungi and bacteria, followed by the NIOSH sampler. Personal sampling was performed in a pig farm to assess occupational bioaerosol exposure and to evaluate the sampling/analysis methods. The Button and IOM samplers yielded a similar performance for personal bioaerosol sampling at the pig farm. However, the Button sampler is more likely to be clogged at high airborne dust concentrations because of its higher flow rate (4 L/min). Therefore, the IOM sampler is a more appropriate choice for performing personal sampling in environments with high dust levels. In summary, the Button and IOM samplers with PC filters are efficient sampling/analysis methods for the personal exposure assessment of multiple bioaerosols.

  10. In vitro evaluation of heat and moisture exchangers designed for spontaneously breathing tracheostomized patients.

    PubMed

    Brusasco, Claudia; Corradi, Francesco; Vargas, Maria; Bona, Margherita; Bruno, Federica; Marsili, Maria; Simonassi, Francesca; Santori, Gregorio; Severgnini, Paolo; Kacmarek, Robert M; Pelosi, Paolo

    2013-11-01

    Heat and moisture exchangers (HMEs) are commonly used in chronically tracheostomized spontaneously breathing patients, to condition inhaled air, maintain lower airway function, and minimize the viscosity of secretions. Supplemental oxygen (O2) can be added to most HMEs designed for spontaneously breathing tracheostomized patients. We tested the efficiency of 7 HMEs designed for spontaneously breathing tracheostomized patients, in a normothermic model, at different minute ventilations (VE) and supplemental O2 flows. HME efficiency was evaluated using an in vitro lung model at 2 VE (5 and 15 L/min) and 4 supplemental O2 flows (0, 3, 6, and 12 L/min). Wet and dry temperatures of the inspiratory flow were measured, and absolute humidity was calculated. In addition, HME efficiency at 0, 12, and 24 h use was evaluated, as well as resistance to flow at 0 and 24 h. The progressive increase in O2 flow from 0 to 12 L/min was associated with a reduction in temperature and absolute humidity. Under the same conditions, this effect was greater at lower VE. The HME with the best performance provided an absolute humidity of 26 mg H2O/L and a temperature of 27.8 °C. No significant changes in efficiency or resistance were detected during the 24 h evaluation. The efficiency of HMEs in terms of temperature and absolute humidity is significantly affected by O2 supplementation and V(E).

  11. EVALUATION OF ENGINEERING CONTROLS FOR THE MIXING OF FLAVORINGS CONTAINING DIACETYL AND OTHER VOLATILE INGREDIENTS

    PubMed Central

    Hirst, Deborah V.L.; Dunn, Kevin H.; Shulman, Stanley A.; Hammond, Duane R.; Sestito, Nicholas

    2015-01-01

    Exposures to diacetyl, a primary ingredient of butter flavoring, have been shown to cause respiratory disease among workers who mix flavorings. This study focused on evaluating ventilation controls designed to reduce emissions from the flavor mixing tanks, the major source of diacetyl in the plants. Five exhaust hood configurations were evaluated in the laboratory: standard hinged lid-opened, standard hinged lid-closed, hinged lid-slotted, dome with 38-mm gap, and dome with 114-mm gap. Tracer gas tests were performed to evaluate quantitative capture efficiency for each hood. A perforated copper coil was used to simulate an area source within the 1.2-meter diameter mixing tank. Capture efficiencies were measured at four hood exhaust flow rates (2.83, 5.66, 11.3, and 17.0 cubic meters per minute) and three cross draft velocities (0, 30, and 60 meters per minute). All hoods evaluated performed well with capture efficiencies above 90% for most combinations of exhaust volume and cross drafts. The standard hinged lid was the least expensive to manufacture and had the best average capture efficiency (over 99%) in the closed configuration for all exhaust flow rates and cross drafts. The hinged lid-slotted hood had some of the lowest capture efficiencies at the low exhaust flow rates compared to the other hood designs. The standard hinged lid performed well, even in the open position, and it provided a flexible approach to controlling emissions from mixing tanks. The dome hood gave results comparable to the standard hinged lid but it is more expensive to manufacture. The results of the study indicate that emissions from mixing tanks used in the production of flavorings can be controlled using simple inexpensive exhaust hoods. PMID:24649880

  12. The management and design of economic development projects: A case study of World Bank electricity projects in Egypt

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    El Sabaa, S.M.

    1992-01-01

    This study is concerned with the efficiency of World Bank projects in Egypt. The study seeks improvements in the methods of evaluating public sector projects in Egypt. To approaches are employed: (1) project identification to optimally allocate Egypt's and World Bank's resources; (2) project appraisal to assess the economic viability and efficiency of investments. The electricity sector is compared with the agriculture sector as a means of employing project identification for priority ordering of investment for development in Egypt. The key criteria for evaluation are the impacts of developments of each sector upon Egypt's national objectives and needs. These includemore » employment opportunities, growth, alleviation of poverty, cross comparison of per capita consumption in each sector, economic rate of return, national security, balance of payments and foreign debt. The allocation of scarce investments would have been more efficient in agriculture than in electricity in meeting Egypt's national objectives and needs. World Bank lending programs in Egypt reveal a priority ordering of electricity over agriculture and rural development. World Bank development projects in Egypt have not been optimally identified, and its programs have not followed an efficient allocation of World Bank's and Egypt's resources. The key parameters in evaluating economic viability and efficiency of development projects are: (1) the discount rate (the opportunity cost of public funds); (2) the exchange rate; and (3) the cost of major inputs, as approximated by shadow prices of labor, water, electricity, and transportation for development projects. Alternative approaches to estimating the opportunity cost of public funds are made. The parameters in evaluating the efficiency of projects have not been accurately estimated in the appraisal stage of the World Bank projects in Egypt, resulting in false or misleading information concerning the economic viability and efficiency of the projects.« less

  13. Evaluation of reinitialization-free nonvolatile computer systems for energy-harvesting Internet of things applications

    NASA Astrophysics Data System (ADS)

    Onizawa, Naoya; Tamakoshi, Akira; Hanyu, Takahiro

    2017-08-01

    In this paper, reinitialization-free nonvolatile computer systems are designed and evaluated for energy-harvesting Internet of things (IoT) applications. In energy-harvesting applications, as power supplies generated from renewable power sources cause frequent power failures, data processed need to be backed up when power failures occur. Unless data are safely backed up before power supplies diminish, reinitialization processes are required when power supplies are recovered, which results in low energy efficiencies and slow operations. Using nonvolatile devices in processors and memories can realize a faster backup than a conventional volatile computer system, leading to a higher energy efficiency. To evaluate the energy efficiency upon frequent power failures, typical computer systems including processors and memories are designed using 90 nm CMOS or CMOS/magnetic tunnel junction (MTJ) technologies. Nonvolatile ARM Cortex-M0 processors with 4 kB MRAMs are evaluated using a typical computing benchmark program, Dhrystone, which shows a few order-of-magnitude reductions in energy in comparison with a volatile processor with SRAM.

  14. A usability evaluation of Lazada mobile application

    NASA Astrophysics Data System (ADS)

    Hussain, Azham; Mkpojiogu, Emmanuel O. C.; Jamaludin, Nur Hafiza; Moh, Somia T. L.

    2017-10-01

    This paper reports on a usability evaluation of Lazada mobile application, an online shopping app for mobile devices. The evaluation was conducted using 12 users of ages 18 to 24. Seven (7) were expert users and the other 5 were novice users. The study objectives were to evaluate the perceived effectiveness, efficiency and satisfaction of the mobile application. The result provides a positive feedback and shows that the mobile shopping app is effective, efficient, and satisfying as perceived by the study participants. However, there are some observed usability issues with the main menu and the payment method that necessitates improvements to increase the application's effectiveness, efficiency and satisfaction. The suggested improvements include: 1) the main menu should be capitalized and place on the left side of mobile app and 2) payment method tutorial should be included as a hyperlink in the payment method page. This observation will be helpful to the owners of the application in future version development of the app.

  15. Energy efficiency of mobile soft robots.

    PubMed

    Shui, Langquan; Zhu, Liangliang; Yang, Zhe; Liu, Yilun; Chen, Xi

    2017-11-15

    The performance of mobile soft robots is usually characterized by their locomotion/velocity efficiency, whereas the energy efficiency is a more intrinsic and fundamental criterion for the performance evaluation of independent or integrated soft robots. In this work, a general framework is established to evaluate the energy efficiency of mobile soft robots by considering the efficiency of the energy source, actuator and locomotion, and some insights for improving the efficiency of soft robotic systems are presented. Proposed as the ratio of the desired locomotion kinetic energy to the input mechanical energy, the energy efficiency of locomotion is found to play a critical role in determining the overall energy efficiency of soft robots. Four key factors related to the locomotion energy efficiency are identified, that is, the locomotion modes, material properties, geometric sizes, and actuation states. It is found that the energy efficiency of most mobile soft robots reported in the literature is surprisingly low (mostly below 0.1%), due to the inefficient mechanical energy that essentially does not contribute to the desired locomotion. A comparison of the locomotion energy efficiency for several representative locomotion modes in the literature is presented, showing a descending ranking as: jumping ≫ fish-like swimming > snake-like slithering > rolling > rising/turning over > inchworm-like inching > quadruped gait > earthworm-like squirming. Besides, considering the same locomotion mode, soft robots with lower stiffness, higher density and larger size tend to have higher locomotion energy efficiency. Moreover, a periodic pulse actuation instead of a continuous actuation mode may significantly reduce the input mechanical energy, thus improving the locomotion energy efficiency, especially when the pulse actuation matches the resonant states of the soft robots. The results presented herein indicate a large and necessary space for improving the locomotion energy efficiency, which is of practical significance for the future development and application of soft robots.

  16. [Experimental evaluation of the spraying disinfection efficiency on dental models].

    PubMed

    Zhang, Yi; Fu, Yuan-fei; Xu, Kan

    2013-08-01

    To evaluate the disinfect effect after spraying a new kind of disinfectant on the dental plaster models. The germ-free plaster samples, which were smeared with bacteria compound including Staphylococcus aureus, Escherichia coli, Saccharomyces albicans, Streptococcus mutans and Actinomyces viscosus were sprayed with disinfectants (CaviCide) and glutaraldehyde individually. In one group(5 minutes later) and another group(15 minutes later), the colonies were counted for statistical analysis after sampling, inoculating, and culturing which were used for evaluation of disinfecting efficiency. ANOVA was performed using SPSS12.0 software package. All sample bacteria were eradicated after spraying disinfectants(CaviCide) within 5 minutes and effective bacteria control was retained after 15 minutes. There was significant difference between the disinfecting efficiency of CaviCide and glutaraldehyde. The effect of disinfection with spraying disinfectants (CaviCide) on dental models is quick and effective.

  17. Establishment of a new method to quantitatively evaluate hyphal fusion ability in Aspergillus oryzae.

    PubMed

    Tsukasaki, Wakako; Maruyama, Jun-Ichi; Kitamoto, Katsuhiko

    2014-01-01

    Hyphal fusion is involved in the formation of an interconnected colony in filamentous fungi, and it is the first process in sexual/parasexual reproduction. However, it was difficult to evaluate hyphal fusion efficiency due to the low frequency in Aspergillus oryzae in spite of its industrial significance. Here, we established a method to quantitatively evaluate the hyphal fusion ability of A. oryzae with mixed culture of two different auxotrophic strains, where the ratio of heterokaryotic conidia growing without the auxotrophic requirements reflects the hyphal fusion efficiency. By employing this method, it was demonstrated that AoSO and AoFus3 are required for hyphal fusion, and that hyphal fusion efficiency of A. oryzae was increased by depleting nitrogen source, including large amounts of carbon source, and adjusting pH to 7.0.

  18. Technical efficiency of Shiraz school of medicine in research and education domains: a data envelopment analysis.

    PubMed

    Delavari, Somayeh; Rezaee, Rita; Hatam, Nahid; Delavari, Sajad

    2016-01-01

    Efficiency evaluation of universities and faculties is one of the tools that help managers to identify the departments' strengths and weakness. The main objective of the present research was to measure and compare the technical efficiency of Shiraz school of medicine departments using Data Envelopment Analysis (DEA) technique. This cross-sectional and retrospective study was performed on clinical and non-clinical departments in research and education domains over the period of 2006 to 2011. Different inputs and outputs were considered for research and educational domain separately. Efficiency was measured based on the observed optimal performance. Findings showed that pathology and anatomy departments achieved the score of 100 in technical efficiency in education during 2006 to 2011. During this period, parasitology, psychiatric and pediatrics department's achieved the score of 100 for technical efficiency in research domain. The lowest mean of relative educational efficiency belonged to orthopedic department; as to relative research efficiency, the lowest mean was shown in orthopedics and genetics departments. The mean technical efficiency of non-medical departments in education and research domain was 91.93 and 76.08, respectively, while the mean technical efficiency of the clinical department in educational and research fields was 91.02 and 82.23, respectively. Using multiple input and output in DEA technique provided a comprehensive evaluation of efficiency in Shiraz school of medicine departments. The DEA could successfully estimate the technical efficiency of the departments in research and educational fields. Moreover, the deficiency in each department was found; this could help them to plan for improvement.

  19. Masticatory efficiency contributing to the improved dynamic postural balance: A cross-sectional study.

    PubMed

    Hwang, Hae-Yun; Choi, Jun-Seon; Kim, Hee-Eun

    2018-05-28

    To evaluate whether masticatory efficiency is associated with dynamic postural balance. Masticatory dysfunction can cause deterioration of general health due to nutritional imbalances, thereby negatively affecting postural balance. However, few studies have investigated the association between masticatory efficiency and postural balance. The masticatory efficiency of 74 participants was evaluated by calculating mixing ability index (MAI) using a wax cube. The timed up and go test (TUGT) was used to measure dynamic balance. Participants with an MAI above or below the median value of 1.05 were defined as having high or low masticatory efficiency, respectively. An independent samples t-test was used to identify significant differences in TUGT, according to masticatory efficiency. Analysis of covariance was performed to adjust for confounding factors. Logistic regression analysis was used to assess the correlation between masticatory efficiency and postural balance. The high masticatory efficiency group could complete the TUGT exercise approximately 1.67 seconds faster while maintaining the postural balance, compared to the low masticatory efficiency group (P = .005). Furthermore, the postural imbalance odds of the group with high mastication efficiency decreased by 0.14-fold, relative to the group with low mastication efficiency (95% confidence interval: 0.04-0.46). With some reservations about statistical power, the association found between masticatory efficiency and postural balance justifies further investigations to confirm the strength of the associations, and possibly to identify causal relationships between mastication and posture in old age. © 2018 John Wiley & Sons A/S and The Gerodontology Association. Published by John Wiley & Sons Ltd.

  20. Operationally efficient propulsion system study (OEPSS) data book. Volume 6; Space Transfer Propulsion Operational Efficiency Study Task of OEPSS

    NASA Technical Reports Server (NTRS)

    Harmon, Timothy J.

    1992-01-01

    This document is the final report for the Space Transfer Propulsion Operational Efficiency Study Task of the Operationally Efficient Propulsion System Study (OEPSS) conducted by the Rocketdyne Division of Rockwell International. This Study task studied, evaluated and identified design concepts and technologies which minimized launch and in-space operations and optimized in-space vehicle propulsion system operability.

  1. [Remediation Pb, Cd contaminated soil in lead-zinc mining areas by hydroxyapatite and potassium chloride composites].

    PubMed

    Wang, Li; Li, Yong-Hua; Ji, Yan-Fang; Yang, Lin-Sheng; Li, Hai-Rong; Zhang, Xiu-Wu; Yu, Jiang-Ping

    2011-07-01

    The composite agents containing potassium chloride (KCl) and Hydroxyapatite (HA) were used to remediate the lead and cadmium contaminated soil in Fenghuang lead-zinc mining-smelting areas, Hunan province. The objective of this study was to identify and evaluate the influence of Cl- to the fixing efficiency of Pb and Cd by HA. Two types of contaminated soil (HF-1, HF-2) were chosen and forty treatments were set by five different Hydroxyapatite (HA) dosages and four different Cl- dosages. The toxicity characteristic leaching procedure (TCLP) was used to evaluate the results. It showed that HA could efficiently fix the Pb and Cd from TCLP form. The maximum Pb-fixing efficiency and Cd-fixing efficiency of two types of soil were 83.3%, 97.27% and 35.96%, 57.82% when the HA: Pb: KCl molar ratio was 8: 1: 2. Compared to the fixing efficiency without KCl, KCl at the KCl: Pb molar ratio of 2 improved Pb-fixing efficiency and Cd-fixing efficiency by 6.26%, 0.33% and 7.74%, 0.83% respectively when the HA: Pb molar ratio was 8. Generally, Cl- can improve the Pb/Cd-fixing efficiency in heavy metal contaminated soil by Hydroxyapatite.

  2. Analysis of recovery efficiency in high-temperature aquifer thermal energy storage: a Rayleigh-based method

    NASA Astrophysics Data System (ADS)

    Schout, Gilian; Drijver, Benno; Gutierrez-Neri, Mariene; Schotting, Ruud

    2014-01-01

    High-temperature aquifer thermal energy storage (HT-ATES) is an important technique for energy conservation. A controlling factor for the economic feasibility of HT-ATES is the recovery efficiency. Due to the effects of density-driven flow (free convection), HT-ATES systems applied in permeable aquifers typically have lower recovery efficiencies than conventional (low-temperature) ATES systems. For a reliable estimation of the recovery efficiency it is, therefore, important to take the effect of density-driven flow into account. A numerical evaluation of the prime factors influencing the recovery efficiency of HT-ATES systems is presented. Sensitivity runs evaluating the effects of aquifer properties, as well as operational variables, were performed to deduce the most important factors that control the recovery efficiency. A correlation was found between the dimensionless Rayleigh number (a measure of the relative strength of free convection) and the calculated recovery efficiencies. Based on a modified Rayleigh number, two simple analytical solutions are proposed to calculate the recovery efficiency, each one covering a different range of aquifer thicknesses. The analytical solutions accurately reproduce all numerically modeled scenarios with an average error of less than 3 %. The proposed method can be of practical use when considering or designing an HT-ATES system.

  3. Benchmarking and Self-Assessment in the Wine Industry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Galitsky, Christina; Radspieler, Anthony; Worrell, Ernst

    2005-12-01

    Not all industrial facilities have the staff or theopportunity to perform a detailed audit of their operations. The lack ofknowledge of energy efficiency opportunities provides an importantbarrier to improving efficiency. Benchmarking programs in the U.S. andabroad have shown to improve knowledge of the energy performance ofindustrial facilities and buildings and to fuel energy managementpractices. Benchmarking provides a fair way to compare the energyintensity of plants, while accounting for structural differences (e.g.,the mix of products produced, climate conditions) between differentfacilities. In California, the winemaking industry is not only one of theeconomic pillars of the economy; it is also a large energymore » consumer, witha considerable potential for energy-efficiency improvement. LawrenceBerkeley National Laboratory and Fetzer Vineyards developed the firstbenchmarking tool for the California wine industry called "BEST(Benchmarking and Energy and water Savings Tool) Winery". BEST Wineryenables a winery to compare its energy efficiency to a best practicereference winery. Besides overall performance, the tool enables the userto evaluate the impact of implementing efficiency measures. The toolfacilitates strategic planning of efficiency measures, based on theestimated impact of the measures, their costs and savings. The tool willraise awareness of current energy intensities and offer an efficient wayto evaluate the impact of future efficiency measures.« less

  4. Autonomous Dirigible Airships: A Comparative Analysis and Operational Efficiency Evaluation for Logistical Use in Complex Environments

    DTIC Science & Technology

    2012-06-01

    This document was downloaded on August 16, 2012 at 10:14:04 Author(s) Acton, Brian E.; Taylor, David L. Title Autonomous Dirigible Airships: a ...Autonomous Dirigible Airships: A Comparative Analysis and Operational Efficiency Evaluation for Logistical Use in Complex Environments...2. REPORT DATE June 2012 3. REPORT TYPE AND DATES COVERED MBA Professional Report 4. TITLE AND SUBTITLE: Autonomous Dirigible Airships: A

  5. Experimental Validation of the Efficiency of Gamalant-paste-FORTE Plus, a Russian Osteoinductive Material, in Oral Surgery.

    PubMed

    Olesova, V N; Amkhadova, M A; Simakova, T G; Mirgazizov, M Z; Pozharitskaya, M M

    2017-03-01

    For evaluation of the efficiency of bone substitute, nanostructurized Gamalant-paste-FORTEPlus was placed into a mandibular defect in rats. Bone tissue reparation was evaluated after 30 days by histological methods under a microscope. Use of bone substitute in experimental mandibular defect ensured more complete and rapid restructuring of the bone tissue in comparison with the control (natural healing).

  6. Farmers' Knowledge Attributes Contribute to Attaining Higher Farm Technical Efficiency: A Transition Economy Case

    ERIC Educational Resources Information Center

    Manevska-Tasevska, Gordana

    2013-01-01

    Purpose: This study sought to explore how farmers' knowledge attributes influence the technical efficiency of their farms. In addition, farm efficiency was compared to the actual Macedonian Rural Development Programme (RDP) (2007-2013) and instruments considered to improve Macedonian education potential were evaluated. Design/methodology/approach:…

  7. Chapter 20: Data Center IT Efficiency Measures Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurnik, Charles W; Huang, Robert; Masanet, Eric

    This chapter focuses on IT measures in the data center and examines the techniques and analysis methods used to verify savings that result from improving the efficiency of two specific pieces of IT equipment: servers and data storage.

  8. Evaluation of U.S. southern pine stumpage market informational efficiency

    Treesearch

    Jeffrey P. Prestemon

    2003-01-01

    The literature on informational efficiency of southern timber markets conflicts. Part of this conflict is because of differences in how efficiency was tested. In this paper, price behavior tests are based on deflated ("real") southern pine (Pinus spp.) sawtimber stumpage prices, using some of the same data and tests used in previous...

  9. On the Ionization and Ion Transmission Efficiencies of Different ESI-MS Interfaces

    PubMed Central

    Cox, Jonathan T.; Marginean, Ioan; Smith, Richard D.; Tang, Keqi

    2014-01-01

    The achievable sensitivity of electrospray ionization mass spectrometry (ESI-MS) is largely determined by the ionization efficiency in the ESI source and ion transmission efficiency through the ESI-MS interface. These performance characteristics are difficult to evaluate and compare across multiple platforms as it is difficult to correlate electrical current measurements to actual analyte ions reaching the detector of a mass spectrometer. We present an effective method to evaluate the overall ion utilization efficiency of an ESI-MS interface by measuring the total gas phase ion current transmitted through the interface and correlating it to the observed ion abundance measured in the corresponding mass spectrum. Using this method we systematically studied the ion transmission and ionization efficiencies of different ESI-MS interface configurations, including a single emitter/single inlet capillary, single emitter/multi-inlet capillary, and a subambient pressure ionization with nanoelectrospray (SPIN) MS interface with a single emitter and an emitter array, respectively. Our experimental results indicate that the overall ion utilization efficiency of SPIN-MS interface configurations exceeds that of the inlet capillary-based ESI-MS interface configurations. PMID:25267087

  10. On the ionization and ion transmission efficiencies of different ESI-MS interfaces.

    PubMed

    Cox, Jonathan T; Marginean, Ioan; Smith, Richard D; Tang, Keqi

    2015-01-01

    The achievable sensitivity of electrospray ionization mass spectrometry (ESI-MS) is largely determined by the ionization efficiency in the ESI source and ion transmission efficiency through the ESI-MS interface. These performance characteristics are difficult to evaluate and compare across multiple platforms as it is difficult to correlate electrical current measurements to actual analyte ions reaching the detector of a mass spectrometer. We present an effective method to evaluate the overall ion utilization efficiency of an ESI-MS interface by measuring the total gas-phase ion current transmitted through the interface and correlating it to the observed ion abundance measured in the corresponding mass spectrum. Using this method, we systematically studied the ion transmission and ionization efficiencies of different ESI-MS interface configurations, including a single emitter/single inlet capillary, single emitter/multi-inlet capillary, and a subambient pressure ionization with nanoelectrospray (SPIN) MS interface with a single emitter and an emitter array, respectively. Our experimental results indicate that the overall ion utilization efficiency of SPIN-MS interface configurations exceeds that of the inlet capillary-based ESI-MS interface configurations.

  11. Chapter 11: Sample Design Cross-Cutting Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurnik, Charles W; Khawaja, M. Sami; Rushton, Josh

    Evaluating an energy efficiency program requires assessing the total energy and demand saved through all of the energy efficiency measures provided by the program. For large programs, the direct assessment of savings for each participant would be cost-prohibitive. Even if a program is small enough that a full census could be managed, such an undertaking would almost always be an inefficient use of evaluation resources. The bulk of this chapter describes methods for minimizing and quantifying sampling error. Measurement error and regression error are discussed in various contexts in other chapters.

  12. Quantitative Analysis of Defects in Silicon. [to predict energy conversion efficiency of silicon samples for solar cells

    NASA Technical Reports Server (NTRS)

    Natesh, R.; Smith, J. M.; Qidwai, H. A.; Bruce, T.

    1979-01-01

    The evaluation and prediction of the conversion efficiency for a variety of silicon samples with differences in structural defects, such as grain boundaries, twin boundaries, precipitate particles, dislocations, etc. are discussed. Quantitative characterization of these structural defects, which were revealed by etching the surface of silicon samples, is performed by using an image analyzer. Due to different crystal growth and fabrication techniques the various types of silicon contain a variety of trace impurity elements and structural defects. The two most important criteria in evaluating the various silicon types for solar cell applications are cost and conversion efficiency.

  13. Is there an efficient trap or collection method for sampling Anopheles darlingi and other malaria vectors that can describe the essential parameters affecting transmission dynamics as effectively as human landing catches? - A Review

    PubMed Central

    Lima, José Bento Pereira; Rosa-Freitas, Maria Goreti; Rodovalho, Cynara Melo; Santos, Fátima; Lourenço-de-Oliveira, Ricardo

    2014-01-01

    Distribution, abundance, feeding behaviour, host preference, parity status and human-biting and infection rates are among the medical entomological parameters evaluated when determining the vector capacity of mosquito species. To evaluate these parameters, mosquitoes must be collected using an appropriate method. Malaria is primarily transmitted by anthropophilic and synanthropic anophelines. Thus, collection methods must result in the identification of the anthropophilic species and efficiently evaluate the parameters involved in malaria transmission dynamics. Consequently, human landing catches would be the most appropriate method if not for their inherent risk. The choice of alternative anopheline collection methods, such as traps, must consider their effectiveness in reproducing the efficiency of human attraction. Collection methods lure mosquitoes by using a mixture of olfactory, visual and thermal cues. Here, we reviewed, classified and compared the efficiency of anopheline collection methods, with an emphasis on Neotropical anthropophilic species, especially Anopheles darlingi, in distinct malaria epidemiological conditions in Brazil. PMID:25185008

  14. Evaluation of fuel cell system efficiency and degradation at development and during commercialization

    NASA Astrophysics Data System (ADS)

    Gemmen, R. S.; Johnson, C. D.

    Two primary parameters stand out for characterizing fuel cell system performance. The first and most important parameter is system efficiency. This parameter is relatively easy to define, and protocols for its assessment are already available. Another important parameter yet to be fully considered is system degradation. Degradation is important because customers desire to know how long their purchased fuel cell unit will last. The measure of degradation describes this performance factor by quantifying, for example, how the efficiency of the unit degrades over time. While both efficiency and degradation concepts are readily understood, the coupling between these two parameters must also be understood so that proper testing and evaluation of fuel cell systems is achieved. Tests not properly performed, and results not properly understood, may result in improper use of the evaluation data, producing improper R&D planning decisions and financial investments. This paper presents an analysis of system degradation, recommends an approach to its measurement, and shows how these two parameters are related and how one can be "traded-off" for the other.

  15. ITS evaluations and activities.

    DOT National Transportation Integrated Search

    2010-01-01

    Evaluations are critical in promoting innovative practices which may help to provide a safe and efficient transportation system. By conducting such evaluations, we develop quantifiable measures for those in policy development to appreciate and compre...

  16. The improving efficiency frontier of religious not-for-profit hospitals.

    PubMed

    Harrison, Jeffrey P; Sexton, Christopher

    2006-01-01

    By using data-envelopment analysis (DEA), this study evaluates the efficiency of religious not-for-profit hospitals. Hospital executives, healthcare policy makers, taxpayers, and other stakeholders benefit from studies that improve hospital efficiency. Results indicate that overall efficiency in religious hospitals improved from 72% in 1998 to 74% in 2001. What is more important is that the number of religious hospitals operating on the efficiency frontier increased from 40 in 1998 to 47 in 2001. This clearly documents that religious hospitals are becoming more efficient in the management of resources. From a policy perspective, this study highlights the economic importance of encouraging increased efficiency throughout the healthcare industry.

  17. [Indicators of communication and degree of professional integration in healthcare].

    PubMed

    Mola, Ernesto; Maggio, Anna; Vantaggiato, Lucia

    2009-01-01

    According to the chronic care model, improving the management of chronic illness requires efficient communication between health care professionals and the creation of a web of integrated healthcare The aim of this study was to identify an efficient methodology for evaluating the degree of professional integration through indicators related to communication between healthcare professionals. The following types of indicators were identified:-structure indicators to evaluate the presence of prerequisites necessary for implementing the procedures -functional indicators to quantitatively evaluate the use of communications instruments-performance indicators Defining specific indicators may be an appropriate methodology for evaluating the degree of integration and communication between health professionals, available for a bargaining system of incentives.

  18. Field Evaluation of Detection-Control System

    DOT National Transportation Integrated Search

    2014-10-01

    High-speed signalized intersections present unique challenges to improving highway safety. Techniques for achieving safety often have an adverse effect on efficiency, and techniques for achieving efficiency sometimes have an adverse effect on safety....

  19. EM&V for Energy Efficiency Policies and Initiatives

    EPA Pesticide Factsheets

    Learn how representatives of jurisdictions, companies, and other entities can use evaluation, measurement, and verification (EM&V) in demand-side energy efficiency (EE) investments to achieve intended environmental, energy, and economic goals.

  20. Empirical Research on Ecological Development Level of Resource-based Industries-Base on the data of the Silk Road Economic Belt Core Zone

    NASA Astrophysics Data System (ADS)

    Wang, Lei; Yan, Min

    2017-11-01

    Industrial ecology is the epitome of sustainable development in industry level, is one effective gateway to realizing green transformation. On the basis of industrial ecology development, including resource efficiency and environmental efficiency of ecological evaluation index system, this paper evaluates the level of industrial ecology development of resource-based industries in Xinjiang using entropy method. Research shows that the overall ecological development level of resource-based industries has remained at continuous improved trend with slow improvement in resource efficiency, and relative faster improvement in environmental efficiency. With economic development entering into the period of new normal at the end of the “twelfth five year plan”, the resource efficiency of ecological development of resource-based industries demonstrated a downward trend. The overall level of industrial ecology also faced with certain fluctuations, various ecological development level of resource-based industries also presented a downward trend. To promote ecological development of resource-based industries in Xinjiang, countermeasures and suggestions are initiated.

  1. Efficiency of True-Green Light Emitting Diodes: Non-Uniformity and Temperature Effects

    PubMed Central

    Titkov, Ilya E.; Karpov, Sergey Yu.; Yadav, Amit; Mamedov, Denis; Zerova, Vera L.

    2017-01-01

    External quantum efficiency of industrial-grade green InGaN light-emitting diodes (LEDs) has been measured in a wide range of operating currents at various temperatures from 13 K to 300 K. Unlike blue LEDs, the efficiency as a function of current is found to have a multi-peak character, which could not be fitted by a simple ABC-model. This observation correlated with splitting of LED emission spectra into two peaks at certain currents. The characterization data are interpreted in terms of non-uniformity of the LED active region, which is tentatively attributed to extended defects like V-pits. We suggest a new approach to evaluation of temperature-dependent light extraction and internal quantum efficiencies taking into account the active region non-uniformity. As a result, the temperature dependence of light extraction and internal quantum efficiencies have been evaluated in the temperature range mentioned above and compared with those of blue LEDs. PMID:29156543

  2. Evaluation of the energy efficiency of enzyme fermentation by mechanistic modeling.

    PubMed

    Albaek, Mads O; Gernaey, Krist V; Hansen, Morten S; Stocks, Stuart M

    2012-04-01

    Modeling biotechnological processes is key to obtaining increased productivity and efficiency. Particularly crucial to successful modeling of such systems is the coupling of the physical transport phenomena and the biological activity in one model. We have applied a model for the expression of cellulosic enzymes by the filamentous fungus Trichoderma reesei and found excellent agreement with experimental data. The most influential factor was demonstrated to be viscosity and its influence on mass transfer. Not surprisingly, the biological model is also shown to have high influence on the model prediction. At different rates of agitation and aeration as well as headspace pressure, we can predict the energy efficiency of oxygen transfer, a key process parameter for economical production of industrial enzymes. An inverse relationship between the productivity and energy efficiency of the process was found. This modeling approach can be used by manufacturers to evaluate the enzyme fermentation process for a range of different process conditions with regard to energy efficiency. Copyright © 2011 Wiley Periodicals, Inc.

  3. Investigating emergency room service quality using lean manufacturing.

    PubMed

    Abdelhadi, Abdelhakim

    2015-01-01

    The purpose of this paper is to investigate a lean manufacturing metric called Takt time as a benchmark evaluation measure to evaluate a public hospital's service quality. Lean manufacturing is an established managerial philosophy with a proven track record in industry. A lean metric called Takt time is applied as a measure to compare the relative efficiency between two emergency departments (EDs) belonging to the same public hospital. Outcomes guide managers to improve patient services and increase hospital performances. The patient treatment lead time within the hospital's two EDs (one department serves male and the other female patients) are the study's focus. A lean metric called Takt time is used to find the service's relative efficiency. Findings show that the lean manufacturing metric called Takt time can be used as an effective way to measure service efficiency by analyzing relative efficiency and identifies bottlenecks in different departments providing the same services. The paper presents a new procedure to compare relative efficiency between two EDs. It can be applied to any healthcare facility.

  4. Energy-efficient ovens for unpolluted balady bread

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gadalla, M.A.; Mansour, M.S.; Mahdy, E.

    A new bread oven has been developed, tested and presented in this work for local balady bread. The design has the advantage of being efficient and producing unpolluted bread. An extensive study of the conventional and available designs has been carried out in order to help developing the new design. Evaluation of the conventional design is based on numerous tests and measurements. A computer code utilizing the indirect method has been developed to evaluate the thermal performance of the tested ovens. The present design achieves higher thermal efficiency of about 50% than the conventional ones. In addition, its capital costmore » is much cheaper than other imported designs. Thus, the present design achieves higher efficiency, pollutant free products and less cost. Moreover, it may be modified for different types of bread baking systems.« less

  5. A wind tunnel test of newly developed personal bioaerosol samplers.

    PubMed

    Su, Wei-Chung; Tolchinsky, Alexander D; Sigaev, Vladimir I; Cheng, Yung Sung

    2012-07-01

    In this study the performance of two newly developed personal bioaerosol samplers was evaluated. The two test samplers are cyclone-based personal samplers that incorporate a recirculating liquid film. The performance evaluations focused on the physical efficiencies that a personal bioaerosol sampler could provide, including aspiration, collection, and capture efficiencies. The evaluation tests were carried out in a wind tunnel, and the test personal samplers were mounted on the chest of a full-size manikin placed in the test chamber of the wind tunnel. Monodisperse fluorescent aerosols ranging from 0.5 to 20 microm were used to challenge the samplers. Two wind speeds of 0.5 and 2.0 m/sec were employed as the test wind speeds in this study. The test results indicated that the aspiration efficiency of the two test samplers closely agreed with the ACGIH inhalable convention within the size range of the test aerosols. The aspiration efficiency was found to be independent of the sampling orientation. The collection efficiency acquired from these two samplers showed that the 50% cutoff diameters were both around 0.6 microm. However the wall loss of these two test samplers increased as the aerosol size increased, and the wall loss of PAS-4 was considerably higher than that of PAS-5, especially in the aerosol size larger than 5 microm, which resulted in PAS-4 having a relatively lower capture efficiency than PAS-5. Overall, the PAS-5 is considered a better personal bioaerosol sampler than the PAS-4.

  6. A New Strategy to Evaluate Technical Efficiency in Hospitals Using Homogeneous Groups of Casemix : How to Evaluate When There is Not DRGs?

    PubMed

    Villalobos-Cid, Manuel; Chacón, Max; Zitko, Pedro; Instroza-Ponta, Mario

    2016-04-01

    The public health system has restricted economic resources. Because of that, it is necessary to know how the resources are being used and if they are properly distributed. Several works have applied classical approaches based in Data Envelopment Analysis (DEA) and Stochastic Frontier Analysis (SFA) for this purpose. However, if we have hospitals with different casemix, this is not the best approach. In order to avoid biases in the comparisons, other works have recommended the use of hospital production data corrected by the weights from Diagnosis Related Groups (DRGs), to adjust the casemix of hospitals. However, not all countries have this tool fully implemented, which limits the efficiency evaluation. This paper proposes a new approach for evaluating the efficiency of hospitals. It uses a graph-based clustering algorithm to find groups of hospitals that have similar production profiles. Then, DEA is used to evaluate the technical efficiency of each group. The proposed approach is tested using the production data from 2014 of 193 Chilean public hospitals. The results allowed to identify different performance profiles of each group, that differs from other studies that employs data from partially implemented DRGs. Our results are able to deliver a better description of the resource management of the different groups of hospitals. We have created a website with the results ( bioinformatic.diinf.usach.cl/publichealth ). Data can be requested to the authors.

  7. Efficient evaluation of wireless real-time control networks.

    PubMed

    Horvath, Peter; Yampolskiy, Mark; Koutsoukos, Xenofon

    2015-02-11

    In this paper, we present a system simulation framework for the design and performance evaluation of complex wireless cyber-physical systems. We describe the simulator architecture and the specific developments that are required to simulate cyber-physical systems relying on multi-channel, multihop mesh networks. We introduce realistic and efficient physical layer models and a system simulation methodology, which provides statistically significant performance evaluation results with low computational complexity. The capabilities of the proposed framework are illustrated in the example of WirelessHART, a centralized, real-time, multi-hop mesh network designed for industrial control and monitor applications.

  8. SEE Action Guide for States: Evaluation, Measurement, and Verification Frameworks$-$Guidance for Energy Efficiency Portfolios Funded by Utility Customers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Michael; Dietsch, Niko

    2018-01-01

    This guide describes frameworks for evaluation, measurement, and verification (EM&V) of utility customer–funded energy efficiency programs. The authors reviewed multiple frameworks across the United States and gathered input from experts to prepare this guide. This guide provides the reader with both the contents of an EM&V framework, along with the processes used to develop and update these frameworks.

  9. Evaluation of the Efficiency of Liquid Cooling Garments using a Thermal Manikin

    DTIC Science & Technology

    2005-05-01

    temperatures. The software also calculates thermal resistances and evaporative resistances. TM tests were run dry (i.e. no sweating ) and wet (i.e...REPORT DOCUMENTATION PAGE Form ApprovedOMB No . 0704-0188 SECURITY CLASSIFICATION OF REPORT SECURITY CLASSIFICATION OF THIS PAGE SECURITY CLASSIFICATION...OF ABSTRACT 8. M05-17 1. AGENCY USE ONLY (Leave blank) 4. TITLE AND SUBTITLE EVALUATION OF THE EFFICIENCY OF LIQUID COOLING GARMENTS USING A THERMAL

  10. Evaluation of certain material films flown on the Space Shuttle Mission 46, EOIM-3 experiment

    NASA Technical Reports Server (NTRS)

    Scialdone, John; Clatterbuck, Carroll; Ayres-Treusdell, Mary; Park, Gloria; Kolos, Diane

    1995-01-01

    Nine film samples were carried aboard the STS-46 Atlantis shuttle to complement the 'Evaluation of Oxygen Interaction with Materials (EOIM-III)' experiment to evaluate the effects of atomic oxygen on materials and to monitor the gaseous environment in the shuttle bay. The morphological changes of the samples produced by the atomic oxygen fluence of 2.07E-20 atoms/sq cm have been reported. The changes have been verified using X-ray Photoelectron Spectrometer (XPS) also known as Electron Spectroscopy for Chemical Analysis (ESCA), gravimetric measurements, microscopic observations and thermo-optical measurements. The samples including Kapton, Tefzel, Aclar, Polyacrylonitrile film, and Llumalloy films have been characterized by their oxygen reaction efficiency on the basis of their erosion losses and the fluence. Those efficiencies have been compared with results from other similar experiments, when available. The efficiencies of the samples are all in the range of E-24 gm/atom.

  11. Research, science and technology parks: A global comparison of best practices

    NASA Astrophysics Data System (ADS)

    Ruiz Villacres, Hugo D.

    The purpose of this study was to determine if significant differences exist in the evaluation of effectiveness and efficiency between North American, European, and Asian research parks (RPs). Park directors and staff responded to 25 questions from the Survey for Research, Science and Technology Parks. Effectiveness was measured by director's perception of the RP's contribution to economic growth and job creation. Efficiency was evaluated by the interactions between local universities and research parks, assessment of the ecosystem's basic characteristics, and the culture of innovation in the ecosystem. A stratified sampling procedure from a population of 793 parks was used; analysis of variance (ANOVA) and multivariate analysis of variance (MANOVA) were used to test for significance. 130 RPs from three continents participated in this study. No significant differences were found in the evaluation of RPs' directors on effectiveness and efficiency of RPs.

  12. New Automotive Air Conditioning System Simulation Tool Developed in MATLAB/Simulink

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kiss, T.; Chaney, L.; Meyer, J.

    Further improvements in vehicle fuel efficiency require accurate evaluation of the vehicle's transient total power requirement. When operated, the air conditioning (A/C) system is the largest auxiliary load on a vehicle; therefore, accurate evaluation of the load it places on the vehicle's engine and/or energy storage system is especially important. Vehicle simulation software, such as 'Autonomie,' has been used by OEMs to evaluate vehicles' energy performance. A transient A/C simulation tool incorporated into vehicle simulation models would also provide a tool for developing more efficient A/C systems through a thorough consideration of the transient A/C system performance. The dynamic systemmore » simulation software Matlab/Simulink was used to develop new and more efficient vehicle energy system controls. The various modeling methods used for the new simulation tool are described in detail. Comparison with measured data is provided to demonstrate the validity of the model.« less

  13. Efficiency of including first-generation information in second-generation ranking and selection: results of computer simulation.

    Treesearch

    T.Z. Ye; K.J.S. Jayawickrama; G.R. Johnson

    2006-01-01

    Using computer simulation, we evaluated the impact of using first-generation information to increase selection efficiency in a second-generation breeding program. Selection efficiency was compared in terms of increase in rank correlation between estimated and true breeding values (i.e., ranking accuracy), reduction in coefficient of variation of correlation...

  14. Gaining Campaign Support through Peer Networking: An Impact Analysis of Energy Efficiency Projects in Malaysia

    ERIC Educational Resources Information Center

    Mustafa, Hasrina

    2010-01-01

    This article presents a comprehensive evaluation of the impact of two community projects on energy efficiency held in Malaysia in January 2008. Specifically, the study was undertaken to compare levels of attitudes and practices of energy efficiency between baseline and post-campaign survey; compare electricity consumptions before, one month after,…

  15. Charge Efficiency Tests of Lead/Acid Batteries

    NASA Technical Reports Server (NTRS)

    Rowlette, J. J.

    1984-01-01

    Current, voltage, and gas evolution measured during charge/discharge cycles. Series of standarized tests for evaluating charging efficiency of lead/acid storage batteries described in report. Purpose of tests to provide information for design of battery charger that allows maximum recharge efficiency for electric-vehicle batteries consistent with other operating parameters, such as range, water loss, and cycle life.

  16. Effect of water stress on total biomass, tuber yield, harvest index and water use efficiency in Jerusalem artichoke

    USDA-ARS?s Scientific Manuscript database

    The objectives of this study were to determine the effect of drought on tuber yield, total biomass, harvest index, water use efficiency of tuber yield (WUEt) and water use efficiency of biomass (WUEb), and to evaluate the differential responses of Jerusalem artichoke (JA) varieties under drought str...

  17. An analysis of ash and isotopic carbon discrimination (delta13C) methods to evaluate water use efficiency in apple

    USDA-ARS?s Scientific Manuscript database

    Apple cultivars are selected for fruit quality, disease and insect resistance, not water use efficiency (WUE), however, the need for more water use efficient crops is accelerating due to climate change and increased competition for water resources. On a whole plant basis, calculation of water use e...

  18. Coupled optical-thermal-fluid and structural analyses of novel light-trapping tubular panels for concentrating solar power receivers

    NASA Astrophysics Data System (ADS)

    Ortega, Jesus D.; Christian, Joshua M.; Yellowhair, Julius E.; Ho, Clifford K.

    2015-09-01

    Traditional tubular receivers used in concentrating solar power are formed using tubes connected to manifolds to form panels; which in turn are arranged in cylindrical or rectangular shapes. Previous and current tubular receivers, such as the ones used in Solar One, Solar Two, and most recently the Ivanpah solar plants, have used a black paint coating to increase the solar absorptance of the receiver. However, these coatings degrade over time and must be reapplied, increasing the receiver maintenance cost. This paper presents the thermal efficiency evaluation of novel receiver tubular panels that have a higher effective solar absorptance due to a light-trapping effect created by arranging the tubes in each panel into unique geometric configurations. Similarly, the impact of the incidence angle on the effective solar absorptance and thermal efficiency is evaluated. The overarching goal of this work is to achieve effective solar absorptances of ~90% and thermal efficiencies above 85% without using an absorptance coating. Several panel geometries were initially proposed and were down-selected based on structural analyses considering the thermal and pressure loading requirements of molten salt and supercritical carbon-dioxide receivers. The effective solar absorptance of the chosen tube geometries and panel configurations were evaluated using the ray-tracing modeling capabilities of SolTrace. The thermal efficiency was then evaluated by coupling computational fluid dynamics with the ray-tracing results using ANSYS Fluent. Compared to the base case analysis (flat tubular panel), the novel tubular panels have shown an increase in effective solar absorptance and thermal efficiency by several percentage points.

  19. Connected Vehicle Pilot Deployment Program Independent Evaluation: Mobility, Environmental, and Public Agency Efficiency Refined Evaluation Plan - New York City

    DOT National Transportation Integrated Search

    2018-03-01

    The purpose of this report is to provide a refined evaluation plan detailing the approach to be used by the Texas A&M Transportation Institute Connected Vehicle Pilot Deployment Evaluation Team for evaluating the mobility, environmental, and public a...

  20. Transition of genomic evaluation from a research project to a production system

    USDA-ARS?s Scientific Manuscript database

    Genomic data began to be included in official USDA genetic evaluations of dairy cattle in January 2009. Numerous changes to the evaluation system were made to enable efficient management of genomic information, to incorporate it in official evaluations, and to distribute evaluations. Artificial-inse...

  1. Technology Enhanced Teacher Evaluation

    ERIC Educational Resources Information Center

    Teter, Richard B.

    2010-01-01

    The purpose of this research and development study was to design and develop an affordable, computer-based, pre-service teacher assessment and reporting system to allow teacher education institutions and supervising teachers to efficiently enter evaluation criteria, record pre-service teacher evaluations, and generate evaluation reports. The…

  2. For Your Phone Only: Custom Protocols for Efficient Secure Function Evaluation on Mobile Devices (Preprint)

    DTIC Science & Technology

    2012-11-01

    that mobile application developers should reconsider implementing garbled circuits due to their extreme resource usage, and instead rely upon our equivalently secure and significantly more efficient alternative.

  3. Inducing the Development and Adoption of Socially Efficient Automotive Technology

    DOT National Transportation Integrated Search

    1978-02-01

    Federal policies for inducing the development and adoption of innovative automobile technology are examined using a welfare economics framework. Socially efficient technology is defined, and criteria are identified for evaluating public policies; the...

  4. Evaluation of the performance of national health systems in 2004-2011: An analysis of 173 countries.

    PubMed

    Sun, Daxin; Ahn, Haksoon; Lievens, Tomas; Zeng, Wu

    2017-01-01

    In an effort to improve health service delivery and achieve better health outcomes, the World Health Organization (WHO) has called for improved efficiency of health care systems to better use the available funding. This study aims to examine the efficiency of national health systems using longitudinal country-level data. Data on health spending per capita, infant mortality rate (IMR), under 5 mortality rate (U5MR), and life expectancy (LE) were collected from or imputed for 173 countries from 2004 through 2011. Data envelopment analyses were used to evaluate the efficiency and regression models were constructed to examine the determinants of efficiency. The average efficiency of the national health system, when examined yearly, was 78.9%, indicating a potential saving of 21.1% of health spending per capita to achieve the same level of health status for children and the entire population, if all countries performed as well as their peers. Additionally, the efficiency of the national health system varied widely among countries. On average, Africa had the lowest efficiency of 67%, while West Pacific countries had the highest efficiency of 86%. National economic status, HIV/AIDS prevalence, health financing mechanisms and governance were found to be statistically associated with the efficiency of national health systems. Taking health financing as an example, a 1% point increase of social security expenses as a percentage of total health expenditure correlated to a 1.9% increase in national health system efficiency. The study underscores the need to enhance efficiency of national health systems to meet population health needs, and highlights the importance of health financing and governance in improving the efficiency of health systems, to ultimately improve health outcomes.

  5. A Comparative Evaluation of Public Health Centers with Private Health Training Centers on Primary Healthcare Parameters in India: a Study by Data Envelopment Analysis Technique

    PubMed Central

    Davey, Sanjeev; Raghav, Santosh Kumar; Singh, Jai Vir; Davey, Anuradha; Singh, Nirankar

    2015-01-01

    Background: The evaluation of primary healthcare services provided by health training centers of a private medical college has not been studied in comparison with government health facilities in Indian context. Data envelopment analysis (DEA) is one such technique of operations research, which can be used on health facilities for identifying efficient operating practices and strategies for relatively efficient or inefficient health centers by calculating their efficiency scores. Materials and Methods: This study was carried out by DEA technique by using basic radial models (constant ratio to scale (CRS)) in linear programming via DEAOS free online Software among four decision making units (DMUs; by comparing efficiency of two private health centers of a private medical college of India with two public health centers) in district Muzaffarnagar of state Uttar Pradesh. The input and output records of all these health facilities (two from private and two from Government); for 6 months duration from 1st Jan 2014 to 1st July 2014 was taken for deciding their efficiency scores. Results: The efficiency scores of primary healthcare services in presence of doctors (100 vs 30%) and presence of health staff (100 vs 92%) were significantly better from government health facilities as compared to private health facilities (P < 0.0001). Conclusions: The evaluation of primary healthcare services delivery by DEA technique reveals that the government health facilities group were more efficient in delivery of primary healthcare services as compared to private training health facilities group, which can be further clarified in by more in-depth studies in future. PMID:26435598

  6. Thin film CdTe based neutron detectors with high thermal neutron efficiency and gamma rejection for security applications

    NASA Astrophysics Data System (ADS)

    Smith, L.; Murphy, J. W.; Kim, J.; Rozhdestvenskyy, S.; Mejia, I.; Park, H.; Allee, D. R.; Quevedo-Lopez, M.; Gnade, B.

    2016-12-01

    Solid-state neutron detectors offer an alternative to 3He based detectors, but suffer from limited neutron efficiencies that make their use in security applications impractical. Solid-state neutron detectors based on single crystal silicon also have relatively high gamma-ray efficiencies that lead to false positives. Thin film polycrystalline CdTe based detectors require less complex processing with significantly lower gamma-ray efficiencies. Advanced geometries can also be implemented to achieve high thermal neutron efficiencies competitive with silicon based technology. This study evaluates these strategies by simulation and experimentation and demonstrates an approach to achieve >10% intrinsic efficiency with <10-6 gamma-ray efficiency.

  7. Analysis of financing efficiency of big data industry in Guizhou province based on DEA models

    NASA Astrophysics Data System (ADS)

    Li, Chenggang; Pan, Kang; Luo, Cong

    2018-03-01

    Taking 20 listed enterprises of big data industry in Guizhou province as samples, this paper uses DEA method to evaluate the financing efficiency of big data industry in Guizhou province. The results show that the pure technical efficiency of big data enterprise in Guizhou province is high, whose mean value reaches to 0.925. The mean value of scale efficiency reaches to 0.749. The average value of comprehensive efficiency reaches 0.693. The comprehensive financing efficiency is low. According to the results of the study, this paper puts forward some policy and recommendations to improve the financing efficiency of the big data industry in Guizhou.

  8. Simple and Efficient Numerical Evaluation of Near-Hypersingular Integrals

    NASA Technical Reports Server (NTRS)

    Fink, Patrick W.; Wilton, Donald R.; Khayat, Michael A.

    2007-01-01

    Recently, significant progress has been made in the handling of singular and nearly-singular potential integrals that commonly arise in the Boundary Element Method (BEM). To facilitate object-oriented programming and handling of higher order basis functions, cancellation techniques are favored over techniques involving singularity subtraction. However, gradients of the Newton-type potentials, which produce hypersingular kernels, are also frequently required in BEM formulations. As is the case with the potentials, treatment of the near-hypersingular integrals has proven more challenging than treating the limiting case in which the observation point approaches the surface. Historically, numerical evaluation of these near-hypersingularities has often involved a two-step procedure: a singularity subtraction to reduce the order of the singularity, followed by a boundary contour integral evaluation of the extracted part. Since this evaluation necessarily links basis function, Green s function, and the integration domain (element shape), the approach ill fits object-oriented programming concepts. Thus, there is a need for cancellation-type techniques for efficient numerical evaluation of the gradient of the potential. Progress in the development of efficient cancellation-type procedures for the gradient potentials was recently presented. To the extent possible, a change of variables is chosen such that the Jacobian of the transformation cancels the singularity. However, since the gradient kernel involves singularities of different orders, we also require that the transformation leaves remaining terms that are analytic. The terms "normal" and "tangential" are used herein with reference to the source element. Also, since computational formulations often involve the numerical evaluation of both potentials and their gradients, it is highly desirable that a single integration procedure efficiently handles both.

  9. Two- and three-dimensional transvaginal ultrasound with power Doppler angiography and gel infusion sonography for diagnosis of endometrial malignancy.

    PubMed

    Dueholm, M; Christensen, J W; Rydbjerg, S; Hansen, E S; Ørtoft, G

    2015-06-01

    To evaluate the diagnostic efficiency of two-dimensional (2D) and three-dimensional (3D) transvaginal ultrasonography, power Doppler angiography (PDA) and gel infusion sonography (GIS) at offline analysis for recognition of malignant endometrium compared with real-time evaluation during scanning, and to determine optimal image parameters at 3D analysis. One hundred and sixty-nine consecutive women with postmenopausal bleeding and endometrial thickness ≥ 5 mm underwent systematic evaluation of endometrial pattern on 2D imaging, and 2D videoclips and 3D volumes were later analyzed offline. Histopathological findings at hysteroscopy or hysterectomy were used as the reference standard. The efficiency of the different techniques for diagnosis of malignancy was calculated and compared. 3D image parameters, endometrial volume and 3D vascular indices were assessed. Optimal 3D image parameters were transformed by logistic regression into a risk of endometrial cancer (REC) score, including scores for body mass index, endometrial thickness and endometrial morphology at gray-scale and PDA and GIS. Offline 2D and 3D analysis were equivalent, but had lower diagnostic performance compared with real-time evaluation during scanning. Their diagnostic performance was not markedly improved by the addition of PDA or GIS, but their efficiency was comparable with that of real-time 2D-GIS in offline examinations of good image quality. On logistic regression, the 3D parameters from the REC-score system had the highest diagnostic efficiency. The area under the curve of the REC-score system at 3D-GIS (0.89) was not improved by inclusion of vascular indices or endometrial volume calculations. Real-time evaluation during scanning is most efficient, but offline 2D and 3D analysis is useful for prediction of endometrial cancer when good image quality can be obtained. The diagnostic efficiency at 3D analysis may be improved by use of REC-scoring systems, without the need for calculation of vascular indices or endometrial volume. The optimal imaging modality appears to be real-time 2D-GIS. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.

  10. A new BP Fourier algorithm and its application in English teaching evaluation

    NASA Astrophysics Data System (ADS)

    Pei, Xuehui; Pei, Guixin

    2017-08-01

    BP neural network algorithm has wide adaptability and accuracy when used in complicated system evaluation, but its calculation defects such as slow convergence have limited its practical application. The paper tries to speed up the calculation convergence of BP neural network algorithm with Fourier basis functions and presents a new BP Fourier algorithm for complicated system evaluation. First, shortages and working principle of BP algorithm are analyzed for subsequent targeted improvement; Second, the presented BP Fourier algorithm adopts Fourier basis functions to simplify calculation structure, designs new calculation transfer function between input and output layers, and conducts theoretical analysis to prove the efficiency of the presented algorithm; Finally, the presented algorithm is used in evaluating university English teaching and the application results shows that the presented BP Fourier algorithm has better performance in calculation efficiency and evaluation accuracy and can be used in evaluating complicated system practically.

  11. Implementation and field evaluation of pretensioned concrete girder end crack control.

    DOT National Transportation Integrated Search

    2016-05-01

    Wisconsin bulb tee pretensioned concrete girders are currently used for bridge construction. Their efficiency in load resistance has made them particularly desirable. To provide that efficiency, these girders are heavily prestressed. Cracking is evid...

  12. Energy and Environment Guide to Action - Chapter 4.4: State Appliance Efficiency Standards

    EPA Pesticide Factsheets

    Provides recommendations on designing, implementing, and evaluating state appliance efficiency standards. Appliance standards save energy and generate net benefits for homes, businesses, and industry. State success stories are included for reference.

  13. Comparison of Predicted Thermoelectric Energy Conversion Efficiency by Cumulative Properties and Reduced Variables Approaches

    NASA Astrophysics Data System (ADS)

    Linker, Thomas M.; Lee, Glenn S.; Beekman, Matt

    2018-06-01

    The semi-analytical methods of thermoelectric energy conversion efficiency calculation based on the cumulative properties approach and reduced variables approach are compared for 21 high performance thermoelectric materials. Both approaches account for the temperature dependence of the material properties as well as the Thomson effect, thus the predicted conversion efficiencies are generally lower than that based on the conventional thermoelectric figure of merit ZT for nearly all of the materials evaluated. The two methods also predict material energy conversion efficiencies that are in very good agreement which each other, even for large temperature differences (average percent difference of 4% with maximum observed deviation of 11%). The tradeoff between obtaining a reliable assessment of a material's potential for thermoelectric applications and the complexity of implementation of the three models, as well as the advantages of using more accurate modeling approaches in evaluating new thermoelectric materials, are highlighted.

  14. Experimental Evaluation of Stagnation Point Collection Efficiency of the NACA 0012 Swept Wing Tip

    NASA Technical Reports Server (NTRS)

    Tsao, Jen-Ching; Kreeger, Richard E.

    2010-01-01

    This paper presents the experimental work of a number of icing tests conducted in the Icing Research Tunnel at NASA Glenn Research Center to develop a test method for measuring the local collection efficiency of an impinging cloud at the leading edge of a NACA 0012 swept wing and with the data obtained to further calibrate a proposed correlation for such impingement efficiency calculation as a function of the modified inertia parameter and the sweep angle. The preliminary results showed that there could be some limitation of the test method due to the ice erosion problem when encountered, and also found that, for conditions free of such problem, the stagnation point collection efficiency measurement for sweep angles up to 45 could be well approximated by the proposed correlation. Further evaluation of this correlation is recommended in order to assess its applicability for swept-wing icing scaling analysis.

  15. Efficient GW calculations using eigenvalue-eigenvector decomposition of the dielectric matrix

    NASA Astrophysics Data System (ADS)

    Nguyen, Huy-Viet; Pham, T. Anh; Rocca, Dario; Galli, Giulia

    2011-03-01

    During the past 25 years, the GW method has been successfully used to compute electronic quasi-particle excitation spectra of a variety of materials. It is however a computationally intensive technique, as it involves summations over occupied and empty electronic states, to evaluate both the Green function (G) and the dielectric matrix (DM) entering the expression of the screened Coulomb interaction (W). Recent developments have shown that eigenpotentials of DMs can be efficiently calculated without any explicit evaluation of empty states. In this work, we will present a computationally efficient approach to the calculations of GW spectra by combining a representation of DMs in terms of its eigenpotentials and a recently developed iterative algorithm. As a demonstration of the efficiency of the method, we will present calculations of the vertical ionization potentials of several systems. Work was funnded by SciDAC-e DE-FC02-06ER25777.

  16. Measuring efficiency and productivity growth of new technology-based firms in business incubators: the Portuguese case study of Madan Parque.

    PubMed

    Grilo, A; Santos, J

    2015-01-01

    Business incubators can play a major role in helping to turn a business idea into a technology-based organization that is economically efficient. However, there is a shortage in the literature regarding the efficiency evaluation and productivity evolution of the new technology-based firms (NTBFs) in the incubation scope. This study develops a model based on the data envelopment analysis (DEA) methodology, which allows the incubated NTBFs to evaluate and improve the efficiency of their management. Moreover, the Malmquist index is used to examine productivity change. The index is decomposed into multiple components to give insights into the root sources of productivity change. The proposed model was applied in a case study with 13 NTBFs incubated. From that study, we conclude that inefficient firms invest excessively in research and development (R&D), and, on average, firms have a productivity growth in the period of study.

  17. Miscellaneous and Electronic Loads Energy Efficiency Opportunities for Commercial Buildings: A Collaborative Study by the United States and India

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ghatikar, Girish; Cheung, Iris; Lanzisera, Steven

    This report documents the technical evaluation of a collaborative research, development, and demonstration (RD&D) project that aims to address energy efficiency of Miscellaneous and Electronic Loads (MELs) (referred to as plug loads interchangeably in this report) using load monitoring and control devices. The goal s of this project are to identify and provide energy efficiency and building technologies to exemplary information technology (IT) office buildings, and to assist in transforming markets via technical assistance and engagement of Indian and U.S. stakeholders. This report describes the results of technology evaluation and United States – India collaboration between the Lawrence Berkeley Nationalmore » Laboratory (LBNL), Infosys Technologies Limited (India), and Smartenit, Inc. (U.S.) to address plug - load efficiency. The conclusions and recommendations focus on the larger benefits of such technologies and their impacts on both U.S. and Indian stakeholders.« less

  18. Measuring Efficiency and Productivity Growth of New Technology-Based Firms in Business Incubators: The Portuguese Case Study of Madan Parque

    PubMed Central

    Grilo, A.; Santos, J.

    2015-01-01

    Business incubators can play a major role in helping to turn a business idea into a technology-based organization that is economically efficient. However, there is a shortage in the literature regarding the efficiency evaluation and productivity evolution of the new technology-based firms (NTBFs) in the incubation scope. This study develops a model based on the data envelopment analysis (DEA) methodology, which allows the incubated NTBFs to evaluate and improve the efficiency of their management. Moreover, the Malmquist index is used to examine productivity change. The index is decomposed into multiple components to give insights into the root sources of productivity change. The proposed model was applied in a case study with 13 NTBFs incubated. From that study, we conclude that inefficient firms invest excessively in research and development (R&D), and, on average, firms have a productivity growth in the period of study. PMID:25874266

  19. Use of maize wastewater for the cultivation of the Pleurotus spp. mushroom and optimization of its biological efficiency.

    PubMed

    Loss, Edenes; Royer, Andrea Rafaela; Barreto-Rodrigues, Marcio; Barana, Ana Claudia

    2009-07-30

    This study evaluated the Pleurotus spp. mushroom production process using an effluent from the maize agroindustrial process as a carbon and nitrogen source and as a wetting agent. A complete experimental design based on factorial planning was used to optimize the biological efficiency and evaluate the effect of the concentration of effluent, pH and species of Pleurotus. The results indicated that the effluent affects the biological efficiency for the production of both species of mushrooms at all pH values studied. The maximum biological efficiency predicted by the model (81.36%) corresponded to the point defined by the effluent contents (X(1)=1), pH (X(2)=-1) and fungus species (X(3)=1), specifically 50%, 5.0 and P. floridae, respectively. The results demonstrated that the effluent is a good alternative for the production of Pleurotus mushrooms.

  20. A new method for evaluating radon and thoron alpha-activities per unit volume inside and outside various natural material samples by calculating SSNTD detection efficiencies for the emitted alpha-particles and measuring the resulting track densities.

    PubMed

    Misdaq, M A; Aitnouh, F; Khajmi, H; Ezzahery, H; Berrazzouk, S

    2001-08-01

    A Monte Carlo computer code for determining detection efficiencies of the CR-39 and LR-115 II solid-state nuclear track detectors (SSNTD) for alpha-particles emitted by the uranium and thorium series inside different natural material samples was developed. The influence of the alpha-particle initial energy on the SSNTD detection efficiencies was investigated. Radon (222Rn) and thoron (220Rn) alpha-activities per unit volume were evaluated inside and outside the natural material samples by exploiting data obtained for the detection efficiencies of the SSNTD utilized for the emitted alpha-particles, and measuring the resulting track densities. Results obtained were compared to those obtained by other methods. Radon emanation coefficients have been determined for some of the considered material samples.

  1. Evaluation of the potential of the Stirling engine for heavy duty application

    NASA Technical Reports Server (NTRS)

    Meijer, R. J.; Ziph, B.

    1981-01-01

    A 150 hp four cylinder heavy duty Stirling engine was evaluated. The engine uses a variable stroke power control system, swashplate drive and ceramic insulation. The sensitivity of the design to engine size and heater temperature is investigated. Optimization shows that, with porous ceramics, indicated efficiencies as high as 52% can be achieved. It is shown that the gain in engine efficiency becomes insignificant when the heater temperature is raised above 200 degrees F.

  2. Solar power satellite rectenna design study: Directional receiving elements and parallel-series combining analysis

    NASA Technical Reports Server (NTRS)

    Gutmann, R. J.; Borrego, J. M.

    1978-01-01

    Rectenna conversion efficiencies (RF to dc) approximating 85 percent were demonstrated on a small scale, clearly indicating the feasibility and potential of efficiency of microwave power to dc. The overall cost estimates of the solar power satellite indicate that the baseline rectenna subsystem will be between 25 to 40 percent of the system cost. The directional receiving elements and element extensions were studied, along with power combining evaluation and evaluation extensions.

  3. Energy efficient engine: Propulsion system-aircraft integration evaluation

    NASA Technical Reports Server (NTRS)

    Owens, R. E.

    1979-01-01

    Flight performance and operating economics of future commercial transports utilizing the energy efficient engine were assessed as well as the probability of meeting NASA's goals for TSFC, DOC, noise, and emissions. Results of the initial propulsion systems aircraft integration evaluation presented include estimates of engine performance, predictions of fuel burns, operating costs of the flight propulsion system installed in seven selected advanced study commercial transports, estimates of noise and emissions, considerations of thrust growth, and the achievement-probability analysis.

  4. Microbiological evaluation of the mobile biological isolator system

    NASA Technical Reports Server (NTRS)

    Taylor, D. M.; Morelli, F.; Neiderheiser, W.; Tratz, W. M.

    1979-01-01

    Evaluations on critical components of the mobile biological isolation system were performed. High efficiency particulate air filter efficiency and suit integrity were found to withstand repeated ethylene oxide (ETO) sterilizations. The minimum ETO sterilization time required to inactivate all contaminant organisms was established at four hours. Two days of aerating at 120 F was found to dissipate all harmful ETO residuals from the suit. Donning and doffing procedures were clarified and written specifically for isolation rooms.

  5. Prognosis of physiological disorders in physic nut to N, P, and K deficiency during initial growth.

    PubMed

    Santos, Elcio Ferreira; Macedo, Fernando Giovannetti; Zanchim, Bruno José; Lima, Giuseppina Pace Pereira; Lavres, José

    2017-06-01

    The description of physiological disorders in physic nut plants deficient in nitrogen (N), phosphorus (P) and potassium (K) may help to predict nutritional imbalances before the appearance of visual symptoms and to guide strategies for early nutrient supply. The aim of this study was to evaluate the growth of physic nuts (Jatropha curcas L.) during initial development by analyzing the gas exchange parameters, nutrient uptake and use efficiency, as well as the nitrate reductase and acid phosphatase activities and polyamine content. Plants were grown in a complete nutrient solution and solutions from which N, P or K was omitted. The nitrate reductase activity, phosphatase acid activity, polyamine content and gas exchange parameters from leaves of N, P and K-deficient plants indicates earlier imbalances before the appearance of visual symptoms. Nutrient deficiencies resulted in reduced plant growth, although P- and K-deficient plants retained normal net photosynthesis (A), stomatal conductance (g s ) and instantaneous carboxylation efficiency (k) during the first evaluation periods, as modulated by the P and K use efficiencies. Increased phosphatase acid activity in P-deficient plants may also contribute to the P use efficiency and to A and gs during the first evaluations. Early physiological and biochemical evaluations of N-, P- and K-starved plants may rely on reliable, useful methods to predict early nutritional imbalances. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  6. In Vivo Evaluation of Magnetic Targeting in Mice Colon Tumors with Ultra-Magnetic Liposomes Monitored by MRI.

    PubMed

    Thébault, Caroline J; Ramniceanu, Grégory; Michel, Aude; Beauvineau, Claire; Girard, Christian; Seguin, Johanne; Mignet, Nathalie; Ménager, Christine; Doan, Bich-Thuy

    2018-06-25

    The development of theranostic nanocarriers as an innovative therapy against cancer has been improved by targeting properties in order to optimize the drug delivery to safely achieve its desired therapeutic effect. The aim of this paper is to evaluate the magnetic targeting (MT) efficiency of ultra-magnetic liposomes (UML) into CT26 murine colon tumor by magnetic resonance imaging (MRI). Dynamic susceptibility contrast MRI was applied to assess the bloodstream circulation time. A novel semi-quantitative method called %I 0.25 , based on the intensity distribution in T 2 * -weighted MRI images was developed to compare the accumulation of T 2 contrast agent in tumors with or without MT. To evaluate the efficiency of magnetic targeting, the percentage of pixels under the intensity value I 0.25 (I 0.25  = 0.25(I max  - I min )) was calculated on the intensity distribution histogram. This innovative method of processing MRI images showed the MT efficiency by a %I 0.25 that was significantly higher in tumors using MT compared to passive accumulation, from 15.3 to 28.6 %. This methodology was validated by ex vivo methods with an iron concentration that is 3-fold higher in tumors using MT. We have developed a method that allows a semi-quantitative evaluation of targeting efficiency in tumors, which could be applied to different T 2 contrast agents.

  7. Arsenic Removal and Its Chemistry in Batch Electrocoagulation Studies.

    PubMed

    Sharma, Anshul; Adapureddy, Sri Malini; Goel, Sudha

    2014-04-01

    The aim of this study was to evaluate the impact of different oxidizing agents like light, aeration (by mixing) and electrocoagulation (EC) on the oxidation of As (III) and its subsequent removal in an EC batch reactor. Arsenic solutions prepared using distilled water and groundwater were evaluated. Optimum pH and the effect of varying initial pH on As removal efficiency were also evaluated. MaximumAs (III) removal efficiency with EC, light and aeration was 97% from distilled water and 71% from groundwater. Other results show that EC alone resulted in 90% As removal efficiency in the absence of light and mixing from distilled water and 53.6% from groundwater. Removal with light and mixing but without EC resulted in only 26% As removal from distilled water and 29% from groundwater proving that electro-oxidation and coagulation were more effective in removing arsenic compared to the other oxidizing agents examined. Initial pH was varied from 5 to 10 in distilled water and from 3 to 12 in groundwater for evaluating arsenic removal efficiency by EC. The optimum initial pH for arsenic removal was 7 for distilled water and groundwater. For all initial pHs tested between 5 and 10 in distilled water, the final pH ranged between 7 and 8 indicating that the EC process tends towards near neutral pH under the conditions examined in this study.

  8. Premium Efficiency Motor Selection and Application Guide – A Handbook for Industry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gilbert A. McCoy and John G. Douglass

    2014-02-01

    This handbook informs new motor purchase decisions by identifying energy and cost savings that can come from replacing motors with premium efficiency units. The handbook provides an overview of current motor use in the industrial sector, including the development of motor efficiency standards, currently available and emerging advanced efficiency motor technologies, and guidance on how to evaluate motor efficiency opportunities. It also several tips on getting the most out of industrial motors, such as how to avoid adverse motor interactions with electronic adjustable speed drives and how to ensure efficiency gains are not lost to undervoltage operation or excessive voltagemore » unbalance.« less

  9. Analysis and Evaluation of Processes and Equipment in Tasks 2 and 4 of the Low-cost Solar Array Project

    NASA Technical Reports Server (NTRS)

    Wolf, M.

    1979-01-01

    To facilitate the task of objectively comparing competing process options, a methodology was needed for the quantitative evaluation of their relative cost effectiveness. Such a methodology was developed and is described, together with three examples for its application. The criterion for the evaluation is the cost of the energy produced by the system. The method permits the evaluation of competing design options for subsystems, based on the differences in cost and efficiency of the subsystems, assuming comparable reliability and service life, or of competing manufacturing process options for such subsystems, which include solar cells or modules. This process option analysis is based on differences in cost, yield, and conversion efficiency contribution of the process steps considered.

  10. Evaluation of a metal shear web selectively reinforced with filamentary composites for space shuttle application

    NASA Technical Reports Server (NTRS)

    Laakso, J. H.; Straayer, J. W.

    1974-01-01

    A final program summary is reported for test and evaluation activities that were conducted for space shuttle web selection. Large scale advanced composite shear web components were tested and analyzed to evaluate application of advanced composite shear web construction to a space shuttle orbiter thrust structure. The shear web design concept consisted of a titanium-clad + or - 45 deg boron/epoxy web laminate stiffened with vertical boron-epoxy reinforced aluminum stiffeners and logitudinal aluminum stiffening. The design concept was evaluated to be efficient and practical for the application that was studied. Because of the effects of buckling deflections, a requirement is identified for shear buckling resistant design to maximize the efficiency of highly-loaded advanced composite shear webs.

  11. Comparative evaluation of rRNA depletion procedures for the improved analysis of bacterial biofilm and mixed pathogen culture transcriptomes

    PubMed Central

    Petrova, Olga E.; Garcia-Alcalde, Fernando; Zampaloni, Claudia; Sauer, Karin

    2017-01-01

    Global transcriptomic analysis via RNA-seq is often hampered by the high abundance of ribosomal (r)RNA in bacterial cells. To remove rRNA and enrich coding sequences, subtractive hybridization procedures have become the approach of choice prior to RNA-seq, with their efficiency varying in a manner dependent on sample type and composition. Yet, despite an increasing number of RNA-seq studies, comparative evaluation of bacterial rRNA depletion methods has remained limited. Moreover, no such study has utilized RNA derived from bacterial biofilms, which have potentially higher rRNA:mRNA ratios and higher rRNA carryover during RNA-seq analysis. Presently, we evaluated the efficiency of three subtractive hybridization-based kits in depleting rRNA from samples derived from biofilm, as well as planktonic cells of the opportunistic human pathogen Pseudomonas aeruginosa. Our results indicated different rRNA removal efficiency for the three procedures, with the Ribo-Zero kit yielding the highest degree of rRNA depletion, which translated into enhanced enrichment of non-rRNA transcripts and increased depth of RNA-seq coverage. The results indicated that, in addition to improving RNA-seq sensitivity, efficient rRNA removal enhanced detection of low abundance transcripts via qPCR. Finally, we demonstrate that the Ribo-Zero kit also exhibited the highest efficiency when P. aeruginosa/Staphylococcus aureus co-culture RNA samples were tested. PMID:28117413

  12. Efficient evaluation of three-center Coulomb integrals

    PubMed Central

    Samu, Gyula

    2017-01-01

    In this study we pursue the most efficient paths for the evaluation of three-center electron repulsion integrals (ERIs) over solid harmonic Gaussian functions of various angular momenta. First, the adaptation of the well-established techniques developed for four-center ERIs, such as the Obara–Saika, McMurchie–Davidson, Gill–Head-Gordon–Pople, and Rys quadrature schemes, and the combinations thereof for three-center ERIs is discussed. Several algorithmic aspects, such as the order of the various operations and primitive loops as well as prescreening strategies, are analyzed. Second, the number of floating point operations (FLOPs) is estimated for the various algorithms derived, and based on these results the most promising ones are selected. We report the efficient implementation of the latter algorithms invoking automated programming techniques and also evaluate their practical performance. We conclude that the simplified Obara–Saika scheme of Ahlrichs is the most cost-effective one in the majority of cases, but the modified Gill–Head-Gordon–Pople and Rys algorithms proposed herein are preferred for particular shell triplets. Our numerical experiments also show that even though the solid harmonic transformation and the horizontal recurrence require significantly fewer FLOPs if performed at the contracted level, this approach does not improve the efficiency in practical cases. Instead, it is more advantageous to carry out these operations at the primitive level, which allows for more efficient integral prescreening and memory layout. PMID:28571354

  13. Efficient evaluation of three-center Coulomb integrals.

    PubMed

    Samu, Gyula; Kállay, Mihály

    2017-05-28

    In this study we pursue the most efficient paths for the evaluation of three-center electron repulsion integrals (ERIs) over solid harmonic Gaussian functions of various angular momenta. First, the adaptation of the well-established techniques developed for four-center ERIs, such as the Obara-Saika, McMurchie-Davidson, Gill-Head-Gordon-Pople, and Rys quadrature schemes, and the combinations thereof for three-center ERIs is discussed. Several algorithmic aspects, such as the order of the various operations and primitive loops as well as prescreening strategies, are analyzed. Second, the number of floating point operations (FLOPs) is estimated for the various algorithms derived, and based on these results the most promising ones are selected. We report the efficient implementation of the latter algorithms invoking automated programming techniques and also evaluate their practical performance. We conclude that the simplified Obara-Saika scheme of Ahlrichs is the most cost-effective one in the majority of cases, but the modified Gill-Head-Gordon-Pople and Rys algorithms proposed herein are preferred for particular shell triplets. Our numerical experiments also show that even though the solid harmonic transformation and the horizontal recurrence require significantly fewer FLOPs if performed at the contracted level, this approach does not improve the efficiency in practical cases. Instead, it is more advantageous to carry out these operations at the primitive level, which allows for more efficient integral prescreening and memory layout.

  14. [Integrated health care organizations: guideline for analysis].

    PubMed

    Vázquez Navarrete, M Luisa; Vargas Lorenzo, Ingrid; Farré Calpe, Joan; Terraza Núñez, Rebeca

    2005-01-01

    There has been a tendency recently to abandon competition and to introduce policies that promote collaboration between health providers as a means of improving the efficiency of the system and the continuity of care. A number of countries, most notably the United States, have experienced the integration of health care providers to cover the continuum of care of a defined population. Catalonia has witnessed the steady emergence of increasing numbers of integrated health organisations (IHO) but, unlike the United States, studies on health providers' integration are scarce. As part of a research project currently underway, a guide was developed to study Catalan IHOs, based on a classical literature review and the development of a theoretical framework. The guide proposes analysing the IHO's performance in relation to their final objectives of improving the efficiency and continuity of health care by an analysis of the integration type (based on key characteristics); external elements (existence of other suppliers, type of services' payment mechanisms); and internal elements (model of government, organization and management) that influence integration. Evaluation of the IHO's performance focuses on global strategies and results on coordination of care and efficiency. Two types of coordination are evaluated: information coordination and coordination of care management. Evaluation of the efficiency of the IHO refers to technical and allocative efficiency. This guide may have to be modified for use in the Catalan context.

  15. Improved Engine Performance and Efficiency Utilizing a Superturbocharger

    DTIC Science & Technology

    2012-08-01

    supercharger, turbocharger and turbo-compounder in one single device. This is accomplished by mechanically controlling the speed ratio between the...the engine. This is made possible by a high efficiency turbine wheel. Normal turbochargers must balance the turbine power against the compressor...SuperTurbocharger and compare it against the currently used turbocharger in military vehicles to evaluate the impact on performance and efficiency

  16. Evaluating the Efficiency of Research in Academic Departments: An Empirical Analysis in an Italian Region

    ERIC Educational Resources Information Center

    Agasisti, Tommaso; Dal Bianco, Antonio; Landoni, Paolo; Sala, Alessandro; Salerno, Mario

    2011-01-01

    This paper investigates the efficiency of university departments in science, technology and medicine in an Italian Region (Lombardy). The aim of the paper is twofold: (i) to analyse the changes in productivity in recent years (from 2004 and 2007); and (ii) to detect factors that are potentially affecting efficiency. The research benefited from a…

  17. Spin torque efficiency of Ta, W, and Pt in metallic bilayers evaluated by harmonic Hall and spin Hall magnetoresistance measurements

    NASA Astrophysics Data System (ADS)

    Lau, Yong-Chang; Hayashi, Masamitsu

    2017-08-01

    We investigate the efficiency of current-induced torque, i.e., the spin torque efficiency, in in-plane magnetized heavy metal/CoFeB/MgO heterostructures (heavy metals = Pt, W, and Ta) using the harmonic Hall technique and the spin Hall magnetoresistance. We find that the amplitude of the external magnetic field has a strong influence on the spin torque efficiency evaluation by the harmonic Hall measurements. This can be corrected by measuring the corresponding Hall resistance susceptibility. The sign and magnitude of the resulting Slonczewski-like spin torque efficiencies are in agreement with previous reports and the measurements utilizing the spin Hall magnetoresistance, except for the Pt underlayer films. The origin of the discrepancy for the Pt underlayer films is unclear. The field like torque efficiencies, upon subtracting the Oersted field contribution, are quite low or negligible. This is in significant contrast to what has been found for the field like torque in heterostructures with perpendicular magnetization. These results suggest that a more advanced model is required in order to describe accurately spin transport and momentum transfer at metallic interfaces.

  18. The quantile regression approach to efficiency measurement: insights from Monte Carlo simulations.

    PubMed

    Liu, Chunping; Laporte, Audrey; Ferguson, Brian S

    2008-09-01

    In the health economics literature there is an ongoing debate over approaches used to estimate the efficiency of health systems at various levels, from the level of the individual hospital - or nursing home - up to that of the health system as a whole. The two most widely used approaches to evaluating the efficiency with which various units deliver care are non-parametric data envelopment analysis (DEA) and parametric stochastic frontier analysis (SFA). Productivity researchers tend to have very strong preferences over which methodology to use for efficiency estimation. In this paper, we use Monte Carlo simulation to compare the performance of DEA and SFA in terms of their ability to accurately estimate efficiency. We also evaluate quantile regression as a potential alternative approach. A Cobb-Douglas production function, random error terms and a technical inefficiency term with different distributions are used to calculate the observed output. The results, based on these experiments, suggest that neither DEA nor SFA can be regarded as clearly dominant, and that, depending on the quantile estimated, the quantile regression approach may be a useful addition to the armamentarium of methods for estimating technical efficiency.

  19. Optimizing Cubature for Efficient Integration of Subspace Deformations

    PubMed Central

    An, Steven S.; Kim, Theodore; James, Doug L.

    2009-01-01

    We propose an efficient scheme for evaluating nonlinear subspace forces (and Jacobians) associated with subspace deformations. The core problem we address is efficient integration of the subspace force density over the 3D spatial domain. Similar to Gaussian quadrature schemes that efficiently integrate functions that lie in particular polynomial subspaces, we propose cubature schemes (multi-dimensional quadrature) optimized for efficient integration of force densities associated with particular subspace deformations, particular materials, and particular geometric domains. We support generic subspace deformation kinematics, and nonlinear hyperelastic materials. For an r-dimensional deformation subspace with O(r) cubature points, our method is able to evaluate subspace forces at O(r2) cost. We also describe composite cubature rules for runtime error estimation. Results are provided for various subspace deformation models, several hyperelastic materials (St.Venant-Kirchhoff, Mooney-Rivlin, Arruda-Boyce), and multimodal (graphics, haptics, sound) applications. We show dramatically better efficiency than traditional Monte Carlo integration. CR Categories: I.6.8 [Simulation and Modeling]: Types of Simulation—Animation, I.3.5 [Computer Graphics]: Computational Geometry and Object Modeling—Physically based modeling G.1.4 [Mathematics of Computing]: Numerical Analysis—Quadrature and Numerical Differentiation PMID:19956777

  20. Observer efficiency in free-localization tasks with correlated noise.

    PubMed

    Abbey, Craig K; Eckstein, Miguel P

    2014-01-01

    The efficiency of visual tasks involving localization has traditionally been evaluated using forced choice experiments that capitalize on independence across locations to simplify the performance of the ideal observer. However, developments in ideal observer analysis have shown how an ideal observer can be defined for free-localization tasks, where a target can appear anywhere in a defined search region and subjects respond by localizing the target. Since these tasks are representative of many real-world search tasks, it is of interest to evaluate the efficiency of observer performance in them. The central question of this work is whether humans are able to effectively use the information in a free-localization task relative to a similar task where target location is fixed. We use a yes-no detection task at a cued location as the reference for this comparison. Each of the tasks is evaluated using a Gaussian target profile embedded in four different Gaussian noise backgrounds having power-law noise power spectra with exponents ranging from 0 to 3. The free localization task had a square 6.7° search region. We report on two follow-up studies investigating efficiency in a detect-and-localize task, and the effect of processing the white-noise backgrounds. In the fixed-location detection task, we find average observer efficiency ranges from 35 to 59% for the different noise backgrounds. Observer efficiency improves dramatically in the tasks involving localization, ranging from 63 to 82% in the forced localization tasks and from 78 to 92% in the detect-and- localize tasks. Performance in white noise, the lowest efficiency condition, was improved by filtering to give them a power-law exponent of 2. Classification images, used to examine spatial frequency weights for the tasks, show better tuning to ideal weights in the free-localization tasks. The high absolute levels of efficiency suggest that observers are well-adapted to free-localization tasks.

  1. Observer efficiency in free-localization tasks with correlated noise

    PubMed Central

    Abbey, Craig K.; Eckstein, Miguel P.

    2014-01-01

    The efficiency of visual tasks involving localization has traditionally been evaluated using forced choice experiments that capitalize on independence across locations to simplify the performance of the ideal observer. However, developments in ideal observer analysis have shown how an ideal observer can be defined for free-localization tasks, where a target can appear anywhere in a defined search region and subjects respond by localizing the target. Since these tasks are representative of many real-world search tasks, it is of interest to evaluate the efficiency of observer performance in them. The central question of this work is whether humans are able to effectively use the information in a free-localization task relative to a similar task where target location is fixed. We use a yes-no detection task at a cued location as the reference for this comparison. Each of the tasks is evaluated using a Gaussian target profile embedded in four different Gaussian noise backgrounds having power-law noise power spectra with exponents ranging from 0 to 3. The free localization task had a square 6.7° search region. We report on two follow-up studies investigating efficiency in a detect-and-localize task, and the effect of processing the white-noise backgrounds. In the fixed-location detection task, we find average observer efficiency ranges from 35 to 59% for the different noise backgrounds. Observer efficiency improves dramatically in the tasks involving localization, ranging from 63 to 82% in the forced localization tasks and from 78 to 92% in the detect-and- localize tasks. Performance in white noise, the lowest efficiency condition, was improved by filtering to give them a power-law exponent of 2. Classification images, used to examine spatial frequency weights for the tasks, show better tuning to ideal weights in the free-localization tasks. The high absolute levels of efficiency suggest that observers are well-adapted to free-localization tasks. PMID:24817854

  2. A clear trade-off exists between the theoretical efficiency and acceptability of dietary changes that improve nutrient adequacy during early pregnancy in French women: Combined data from simulated changes modeling and online assessment survey.

    PubMed

    Bianchi, Clélia M; Huneau, Jean-François; Barbillon, Pierre; Lluch, Anne; Egnell, Manon; Fouillet, Hélène; Verger, Eric O; Mariotti, François

    2018-01-01

    During pregnancy, the diet of a mother-to-be should be adapted to meet increases in nutrient requirements. We analyzed the theoretical efficiency and acceptability of different types of tailored dietary changes for pregnant women. The nutrient adequacy of the diet was evaluated using the PANDiet score, by comparing the nutrient intakes of 344 non-pregnant premenopausal women (18-44y) with dietary reference intakes for the first trimester of pregnancy. Simulations were performed to evaluate the theoretical efficiency of three types of ten successive tailored dietary changes in improving nutrient adequacy, with graded difficulty in implementation. The acceptability (declared intention to use in the diet) of most efficient dietary changes was evaluated during an online randomized study including 115 French pregnant women (22-41y). Modifying the amount consumed of foods (type-1) did not modify the food repertoire and resulted in the smallest theoretical efficiency (increase in the PANDiet score of 9.8±0.2 points), but changes were the most acceptable (probability of the intention to use: 0.30-0.78). Conversely, replacing food items by items from the same group or eaten at the same time (type-3) broadened the food repertoire (3.6±1.3 food subgroups added) and resulted in the greatest theoretical efficiency (+23.9±0.3) but changes were the least acceptable (0.07-0.23). Replacing food items within the same subgroup (type-2) slightly broadened the food repertoire (+8.0±1.3 foods) and resulted in moderate theoretical efficiency (+14.8±0.2) and intermediate acceptability (0.11-0.35). A clear trade-off exists between the theoretical efficiency and acceptability of dietary changes, with a graded broadening of the food repertoire.

  3. On evaluating health centers groups in Lisbon and Tagus Valley: efficiency, equity and quality

    PubMed Central

    2013-01-01

    Background Bearing in mind the increasing health expenses and their weight in the Portuguese gross domestic product, it is of the utmost importance to evaluate the performance of Primary Health Care providers taking into account both efficiency, quality and equity. This paper aims to contribute to a better understanding of the performance of Primary Health Care by measuring it in a Portuguese region (Lisbon and Tagus Valley) and identifying best practices. It also intends to evaluate the quality and equity provided. Methods For the purpose of measuring the efficiency of the health care centers (ACES) the non-parametric full frontier technique of data envelopment analysis (DEA) was adopted. The recent partial frontier method of order-m was also used to estimate the influence of exogenous variables on the efficiency of the ACES. The horizontal equity was investigated by applying the non-parametric Kruskal-Wallis test with multiple comparisons. Moreover, the quality of service was analyzed by using the ratio between the complaints and the total activity of the ACES. Results On the whole, a significant level of inefficiency was observed, although there was a general improvement in efficiency between 2009 and 2010. It was found that nursing was the service with the lowest scores. Concerning the horizontal equity, the analysis showed that there is no evidence of relevant disparities between the different subregions(NUTS III). Concerning the exogenous variables, the purchasing power, the percentage of patients aged 65 years old or older and the population size affect the efficiency negatively. Conclusions This research shows that better usage of the available resources and the creation of a learning network and dissemination of best practices will contribute to improvements in the efficiency of the ACES while maintaining or even improving quality and equity. It was also proved that the market structure does matter when efficiency measurement is addressed. PMID:24359014

  4. Coordinating Demand-Side Efficiency Evaluation, Measurement and Verification Among Western States: Options for Documenting Energy and Non-Energy Impacts for the Power Sector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schiller, Steven R.; Schwartz, Lisa C.

    Demand-side energy efficiency (efficiency) represents a low-cost opportunity to reduce electricity consumption and demand and provide a wide range of non-energy benefits, including avoiding air pollution. Efficiency-related energy and non-energy impacts are determined and documented by implementing evaluation, measurement and verification (EM&V) systems. This technical brief describes efficiency EM&V coordination strategies that Western states can consider taking on together, outlines EM&V-related products that might be appropriate for multistate coordination, and identifies some implications of coordination. Coordinating efficiency EM&V activities can save both time and costs for state agencies and stakeholders engaged in efficiency activities and can be particularly beneficial formore » multiple states served by the same utility. First, the brief summarizes basic information on efficiency, its myriad potential benefits and EM&V for assessing those benefits. Second, the brief introduces the concept of multistate EM&V coordination in the context of assessing such benefits, including achievement of state and federal goals to reduce air pollutants.1 Next, the brief presents three coordination strategy options for efficiency EM&V: information clearinghouse/exchange, EM&V product development, and a regional energy efficiency tracking system platform. The brief then describes five regional EM&V products that could be developed on a multistate basis: EM&V reporting formats, database of consistent deemed electricity savings values, glossary of definitions and concepts, efficiency EM&V methodologies, and EM&V professional standards or accreditation processes. Finally, the brief discusses options for next steps that Western states can take to consider multistate coordination on efficiency EM&V. Appendices provide background information on efficiency and EM&V, as well as definitions and suggested resources on the covered topics. This brief is intended to inform state public utility commissions, boards for public and consumer-owned utilities, state energy offices and air agencies, and other organizations involved in discussions about the use of efficiency EM&V.« less

  5. Psychosocial factors and sleep efficiency: discrepancies between subjective and objective evaluations of sleep.

    PubMed

    Jackowska, Marta; Dockray, Samantha; Hendrickx, Hilde; Steptoe, Andrew

    2011-01-01

    Self-reported sleep efficiency may not precisely reflect objective sleep patterns. We assessed whether psychosocial factors and affective responses are associated with discrepancies between subjective reports and objective measures of sleep efficiency. Participants were 199 working women aged 20 to 61 years. Standardized questionnaires were used to assess psychosocial characteristics and affect that included work stress, social support, happiness, and depressive symptoms. Objective measures of sleep were assessed on one week and one leisure night with an Actiheart monitor. Self-reported sleep efficiency was derived from the Jenkins Sleep Problems Scale. Discrepancies between self-reported and objective measures of sleep efficiency were computed by contrasting standardized measures of sleep problems with objectively measured sleep efficiency. Participants varied markedly in the discrepancies between self-reported and objective sleep measures. After adjustment for personal income, age, having children, marital status, body mass index, and negative affect, overcommitment (p = .002), low level of social support (p = .049), and poor self-rated heath (p = .02) were associated with overreporting of sleep difficulties and underestimation of sleep efficiency. Self-reported poor sleep efficiency was more prevalent among those more overcommitted at work (p = .009) and less happy (p = .02), as well as among those with lower level of social support (p = .03) and more depressive symptoms (p = .048), independently of covariates. Objective sleep efficiency was unrelated to psychosocial characteristics or affect. The extent to which self-reported evaluations of sleep efficiency reflect objective experience may be influenced by psychosocial characteristics and affect. Unless potential moderators of self-reported sleep efficiency are taken into account, associations between sleep and psychosocial factors relevant to health may be overestimated.

  6. Evaluating architecture impact on system energy efficiency

    PubMed Central

    Yu, Shijie; Wang, Rui; Luan, Zhongzhi; Qian, Depei

    2017-01-01

    As the energy consumption has been surging in an unsustainable way, it is important to understand the impact of existing architecture designs from energy efficiency perspective, which is especially valuable for High Performance Computing (HPC) and datacenter environment hosting tens of thousands of servers. One obstacle hindering the advance of comprehensive evaluation on energy efficiency is the deficient power measuring approach. Most of the energy study relies on either external power meters or power models, both of these two methods contain intrinsic drawbacks in their practical adoption and measuring accuracy. Fortunately, the advent of Intel Running Average Power Limit (RAPL) interfaces has promoted the power measurement ability into next level, with higher accuracy and finer time resolution. Therefore, we argue it is the exact time to conduct an in-depth evaluation of the existing architecture designs to understand their impact on system energy efficiency. In this paper, we leverage representative benchmark suites including serial and parallel workloads from diverse domains to evaluate the architecture features such as Non Uniform Memory Access (NUMA), Simultaneous Multithreading (SMT) and Turbo Boost. The energy is tracked at subcomponent level such as Central Processing Unit (CPU) cores, uncore components and Dynamic Random-Access Memory (DRAM) through exploiting the power measurement ability exposed by RAPL. The experiments reveal non-intuitive results: 1) the mismatch between local compute and remote memory node caused by NUMA effect not only generates dramatic power and energy surge but also deteriorates the energy efficiency significantly; 2) for multithreaded application such as the Princeton Application Repository for Shared-Memory Computers (PARSEC), most of the workloads benefit a notable increase of energy efficiency using SMT, with more than 40% decline in average power consumption; 3) Turbo Boost is effective to accelerate the workload execution and further preserve the energy, however it may not be applicable on system with tight power budget. PMID:29161317

  7. Evaluating architecture impact on system energy efficiency.

    PubMed

    Yu, Shijie; Yang, Hailong; Wang, Rui; Luan, Zhongzhi; Qian, Depei

    2017-01-01

    As the energy consumption has been surging in an unsustainable way, it is important to understand the impact of existing architecture designs from energy efficiency perspective, which is especially valuable for High Performance Computing (HPC) and datacenter environment hosting tens of thousands of servers. One obstacle hindering the advance of comprehensive evaluation on energy efficiency is the deficient power measuring approach. Most of the energy study relies on either external power meters or power models, both of these two methods contain intrinsic drawbacks in their practical adoption and measuring accuracy. Fortunately, the advent of Intel Running Average Power Limit (RAPL) interfaces has promoted the power measurement ability into next level, with higher accuracy and finer time resolution. Therefore, we argue it is the exact time to conduct an in-depth evaluation of the existing architecture designs to understand their impact on system energy efficiency. In this paper, we leverage representative benchmark suites including serial and parallel workloads from diverse domains to evaluate the architecture features such as Non Uniform Memory Access (NUMA), Simultaneous Multithreading (SMT) and Turbo Boost. The energy is tracked at subcomponent level such as Central Processing Unit (CPU) cores, uncore components and Dynamic Random-Access Memory (DRAM) through exploiting the power measurement ability exposed by RAPL. The experiments reveal non-intuitive results: 1) the mismatch between local compute and remote memory node caused by NUMA effect not only generates dramatic power and energy surge but also deteriorates the energy efficiency significantly; 2) for multithreaded application such as the Princeton Application Repository for Shared-Memory Computers (PARSEC), most of the workloads benefit a notable increase of energy efficiency using SMT, with more than 40% decline in average power consumption; 3) Turbo Boost is effective to accelerate the workload execution and further preserve the energy, however it may not be applicable on system with tight power budget.

  8. Batch technique to evaluate the efficiency of different natural adsorbents for defluoridation from groundwater

    NASA Astrophysics Data System (ADS)

    Kumar, Pankaj; Saraswat, Chitresh; Mishra, Binaya Kumar; Avtar, Ram; Patel, Hiral; Patel, Asha; Sharma, Tejal; Patel, Roshni

    2017-09-01

    Fluoride pollution (with concentration >1.0 mg/L) in groundwater has become a global threat in the recent past due to the lesser availability of potable groundwater resource. In between several defluoridation techniques discovered so far, the adsorption process proved to be most economic and efficient. This study is an effort to evaluate defluoridation efficiency of powdered rice husk, fine chopped rice husk and sawdust by the batch adsorption process. Optimum defluoridation capacity is achieved by optimizing various parameters, viz. dose of adsorbent, pH, contact time and initial concentration. It was found that all three materials can be employed for the defluoridation technique, but powdered rice husk is the best adsorbent in the midst of all three. Powdered rice husk showed fluoride removal efficiency ranging between 85 and 90 % in the contact period of 7 h only in conditions of all optimized parameter. Following this parameter optimization, adsorption efficiency was also evaluated at natural pH of groundwater to minimize the cost of defluoridation. No significant difference was found between fluoride adsorption at optimized pH (pH = 4) and natural one (pH = 7), which concludes that powdered rice husk can be efficiently used for the defluoridation technique at field scale. The adsorption isotherm using this adsorbent perfectly followed Langmuir isotherms. The value of calculated separation factor also suggests the favourable adsorption of fluoride onto this adsorbent under the conditions used for the experiments. The field application for defluoridation of groundwater using this adsorbent (based on pH of natural groundwater there and seasonal variation of temperature) showed the high success rate.

  9. An Evaluation of the Consumer Costs and Benefits of Energy Efficiency Resource Standards

    NASA Astrophysics Data System (ADS)

    Lessans, Mark D.

    Of the modern-day policies designed to encourage energy efficiency, one with a significant potential for impact is that of Energy Efficiency Resource Standards (EERS). EERS policies place the responsibility for meeting an efficiency target on the electric and gas utilities, typically setting requirements for annual reductions in electricity generation or gas distribution to customers as a percentage of sales. To meet these requirements, utilities typically implement demand-side management (DSM) programs, which encourage energy efficiency at the customer level through incentives and educational initiatives. In Maryland, a statewide EERS has provided for programs which save a significant amount of energy, but is ultimately falling short in meeting the targets established by the policy. This study evaluates residential DSM programs offered by Pepco, a utility in Maryland, for cost-effectiveness. However, unlike most literature on the topic, analysis focuses on the costs-benefit from the perspective of the consumer, and not the utility. The results of this study are encouraging: the majority of programs analyzed show that the cost of electricity saved, or levelized cost of saved energy (LCSE), is less expensive than the current retail cost of electricity cost in Maryland. A key goal of this study is to establish a metric for evaluating the consumer cost-effectiveness of participation in energy efficiency programs made available by EERS. In doing so, the benefits of these programs can be effectively marketed to customers, with the hope that participation will increase. By increasing consumer awareness and buy-in, the original goals set out through EERS can be realized and the policies can continue to receive support.

  10. Indicators and Metrics for Evaluating the Sustainability of Chemical Processes

    EPA Science Inventory

    A metric-based method, called GREENSCOPE, has been developed for evaluating process sustainability. Using lab-scale information and engineering assumptions the method evaluates full-scale epresentations of processes in environmental, efficiency, energy and economic areas. The m...

  11. Evaluation of Epoke Bulk Spreader for winter maintenance.

    DOT National Transportation Integrated Search

    2013-12-01

    In the current economic climate, it is imperative to maximize efficiency while minimizing costs. As a : result, ODOT is evaluating new methods to reduce expenditures in their winter maintenance budget. One : such evaluation is of the Epoke Bulk Sprea...

  12. Phase-I investigation of high-efficiency power amplifiers for 325 and 650 MHz

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Raab, Frederick

    2018-01-27

    This Phase-I SBIR grant investigated techniques for high-efficiency power amplification for DoE particle accelerators such as Project X that operate at 325 and 650 MHz. The recommended system achieves high efficiency, high reliability, and hot-swap capability by integrating class-F power amplifiers, class-S modulators, power combiners, and a digital signal processor. Experimental evaluations demonstrate the production of 120 W per transistor with overall efficiencies from 86 percent at 325 MHz and 80 percent at 650 MHz.

  13. Green and efficient sample preparation method for the determination of catalyst residues in margarine by ICP-MS.

    PubMed

    Hartwig, Carla Andrade; Pereira, Rodrigo Mendes; Novo, Diogo La Rosa; Oliveira, Dirce Taina Teixeira; Mesko, Marcia Foster

    2017-11-01

    Responding to the need for green and efficient methods to determine catalyst residues with suitable precision and accuracy in samples with high fat content, the present work evaluates a microwave-assisted ultraviolet digestion (MW-UV) system for margarines and subsequent determination of Ni, Pd and Pt using inductively coupled plasma mass spectrometry (ICP-MS). It was possible to digest up to 500mg of margarine using only 10mL of 4molL -1 HNO 3 with a digestion efficiency higher than 98%. This allowed the determination of catalyst residues using the ICP-MS and free of interferences. For this purpose, the following experimental parameters were evaluated: concentration of digestion solution, sample mass and microwave irradiation program. The residual carbon content was used as a parameter to evaluate the efficiency of digestion and to select the most suitable experimental conditions. The accuracy evaluation was performed by recovery tests using a standard solution and certified reference material, and recoveries ranging from 94% to 99% were obtained for all analytes. The limits of detection for Ni, Pd and Pt using the proposed method were 35.6, 0.264 and 0.302ngg -1 , respectively. When compared to microwave-assisted digestion (MW-AD) in closed vessels using concentrated HNO 3 (used as a reference method for sample digestion), the proposed MW-UV could be considered an excellent alternative for the digestion of margarine, as this method requires only a diluted nitric acid solution for efficient digestion. In addition, MW-UV provides appropriate solutions for further ICP-MS determination with suitable precision (relative standard deviation < 7%) and accuracy for all evaluated analytes. The proposed method was applied to margarines from different brands produced in Brazil, and the concentration of catalyst residues was in agreement with the current legislation or recommendations. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. NASA to Test In-Flight Folding Spanwise Adaptive Wing to Enhance Aircraft Efficiency

    NASA Image and Video Library

    2014-10-21

    The objectives of testing on PTERA include the development of tools and vetting of system integration, evaluation of vehicle control law, and analysis of SAW airworthiness to examine benefits to in-flight efficiency.

  15. Analysis of railroad energy efficiency in the United States.

    DOT National Transportation Integrated Search

    2013-05-01

    The purpose of this study is to provide information about railroad fuel efficiency that may be useful in evaluating transportation energy policies and assessing the sustainability of potential projects. The specific objectives are to (1) develop rail...

  16. CHARACTERIZING COSTS, SAVINGS AND BENEFITS OF A SELECTION OF ENERGY EFFICIENT EMERGING TECHNOLOGIES IN THE UNITED STATES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, T.; Slaa, J.W.; Sathaye, J.

    2010-12-15

    Implementation and adoption of efficient end-use technologies have proven to be one of the key measures for reducing greenhouse gas (GHG) emissions throughout the industries. In many cases, implementing energy efficiency measures is among one of the most cost effective investments that the industry could make in improving efficiency and productivity while reducing CO2 emissions. Over the years, there have been incentives to use resources and energy in a cleaner and more efficient way to create industries that are sustainable and more productive. With the working of energy programs and policies on GHG inventory and regulation, understanding and managing themore » costs associated with mitigation measures for GHG reductions is very important for the industry and policy makers around the world. Successful implementation of emerging technologies not only can help advance productivities and competitiveness but also can play a significant role in mitigation efforts by saving energy. Providing evaluation and estimation of the costs and energy savings potential of emerging technologies is the focus of our work in this project. The overall goal of the project is to identify and select emerging and under-utilized energy-efficient technologies and practices as they are important to reduce energy consumption in industry while maintaining economic growth. This report contains the results from performing Task 2"Technology evaluation" for the project titled"Research Opportunities in Emerging and Under-Utilized Energy-Efficient Industrial Technologies," which was sponsored by California Energy Commission and managed by CIEE. The project purpose is to analyze market status, market potential, and economic viability of selected technologies applicable to the U.S. In this report, LBNL first performed re-assessments of all of the 33 emerging energy-efficient industrial technologies, including re-evaluation of the 26 technologies that were previously identified by Martin et al. (2000) and their potential significance to energy use in the industries, and new evaluation of additional seven technologies. The re-assessments were essentially updated with recent information that we searched and collected from literature to the extent possible. The progress of selected technologies as they diffused into the marketplace from 2000 to 2010 was then discussed in this report. The report also includes updated detailed characterizations of 15 technologies studied in 2000, with comparisons noted.« less

  17. Techno-Economic Analysis of Indian Draft Standard Levels for RoomAir Conditioners

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McNeil, Michael A.; Iyer, Maithili

    The Indian Bureau of Energy Efficiency (BEE) finalized its first set of efficiency standards and labels for room air conditioners in July of 2006. These regulations followed soon after the publication of levels for frost-free refrigerators in the same year. As in the case of refrigerators, the air conditioner program introduces Minimum Efficiency Performance Standards (MEPS) and comparative labels simultaneously, with levels for one to five stars. Also like the refrigerator program, BEE defined several successive program phases of increasing stringency. In support of BEE's refrigerator program, Lawrence Berkeley National Laboratory (LBNL) produced an analysis of national impacts of standardsmore » in collaboration with the Collaborative Labeling and Standards Program (CLASP). That analysis drew on LBNL's experience with standards programs in the United States, as well as many other countries. Subsequently, as part of the process for setting optimal levels for air conditioner regulations, CLASP commissioned LBNL to provide support to BEE in the form of a techno-economic evaluation of air conditioner efficiency technologies. This report describes the methodology and results of this techno-economic evaluation. The analysis consists of three components: (1) Cost effectiveness to consumers of efficiency technologies relative to current baseline. (2) Impacts on the current market from efficiency regulations. (3) National energy and financial impacts. The analysis relied on detailed and up-to-date technical data made available by BEE and industry representatives. Technical parameters were used in conjunction with knowledge about air conditioner use patterns in the residential and commercial sectors, and prevailing marginal electricity prices, in order to give an estimate of per-unit financial impacts. In addition, the overall impact of the program was evaluated by combining unit savings with market forecasts in order to yield national impacts. LBNL presented preliminary results of these analyses in May 2006, at a meeting of BEEs Technical Committee for Air Conditioners. This meeting was attended by a wide array of stakeholder, including industry representatives, engineers and consumer advocates. Comments made by stakeholders at this meeting are incorporated into the final analysis presented in this report. The current analysis begins with the Rating Plan drafted by BEE in 2006, along with an evaluation of the market baseline according to test data submitted by manufacturers. MEPS, label rating levels, and baseline efficiencies are presented in Section 2. First, we compare Indian MEPS with current standards in other countries, and assess their relative stringency. Baseline efficiencies are then used to estimate the fraction of models likely to remain on the market at each phase of the program, and the impact on market-weighted efficiency levels. Section 3 deals with cost-effectiveness of higher efficiency design options. The cost-benefit analysis is grounded in technical parameters provided by industry representatives in India. This data allows for an assessment of financial costs and benefits to consumers as a result of the standards and labeling program. A Life-Cycle Cost (LCC) calculation is used to evaluate the impacts of the program at the unit level, thus providing some insight into the appropriateness of the levels chosen, and additional opportunities for further ratcheting. In addition to LCC, we also calculate payback periods, cost of conserved energy (CCE), and return on investment (ROI). Finally, Section 4 covers national impacts. This is an extension of unit level estimates in the two previous sections. Extrapolation to the national level depends on a forecast of air conditioner purchases (shipments), which we describe here. Following the cost-benefit analysis, we construct several efficiency scenarios including the BEE plan, but also considering further potential for efficiency improvement. These are combined with shipments through a stock accounting model in order to forecast air conditioner energy consumption in each scenario, and associated electricity savings and carbon emission mitigation. Finally, financial costs and savings are scaled to the national level to evaluate net fiscal benefits.« less

  18. The Scale Effects of Engineered Inlets in Urban Hydrologic Processes

    NASA Astrophysics Data System (ADS)

    Shevade, L.; Montalto, F. A.

    2017-12-01

    Runoff from urban surfaces is typically captured by engineered inlets for conveyance to receiving water bodies or treatment plants. Normative hydrologic and hydraulic (H&H) modeling tools generally assume 100% efficient inlets, though observations by the authors suggest this assumption is invalid. The discrepancy is key since the more efficiently the inlet, the more linearly hydrologic processes scale with catchment area. Using several years of remote sensing, the observed efficiencies of urban green infrastructure (GI) facility inlets in New York City are presented, as a function of the morphological and climatological properties of their catchments and events. The rainfall-runoff response is modeled with EPA to assess the degree of inaccuracy that the assumption of efficient inlets introduces in block and neighborhood-scale simulations. Next, an algorithm is presented that incorporates inlet efficiency into SWMM and the improved predictive skill evaluated using Nash-Sutcliffe and root-mean-square error (RMSE). The results are used to evaluate the extent to which decentralized green stormwater management facilities positioned at the low points of urban catchments ought to be designed with larger capacities than their counterparts located further upslope.

  19. A method of evaluating efficiency during space-suited work in a neutral buoyancy environment

    NASA Technical Reports Server (NTRS)

    Greenisen, Michael C.; West, Phillip; Newton, Frederick K.; Gilbert, John H.; Squires, William G.

    1991-01-01

    The purpose was to investigate efficiency as related to the work transmission and the metabolic cost of various extravehicular activity (EVA) tasks during simulated microgravity (whole body water immersion) using three space suits. Two new prototype space station suits, AX-5 and MKIII, are pressurized at 57.2 kPa and were tested concurrently with the operationally used 29.6 kPa shuttle suit. Four male astronauts were asked to perform a fatigue trial on four upper extremity exercises during which metabolic rate and work output were measured and efficiency was calculated in each suit. The activities were selected to simulate actual EVA tasks. The test article was an underwater dynamometry system to which the astronauts were secured by foot restraints. All metabolic data was acquired, calculated, and stored using a computerized indirect calorimetry system connected to the suit ventilation/gas supply control console. During the efficiency testing, steady state metabolic rate could be evaluated as well as work transmitted to the dynamometer. Mechanical efficiency could then be calculated for each astronaut in each suit performing each movement.

  20. Evaluation Method for Fieldlike-Torque Efficiency by Modulation of the Resonance Field

    NASA Astrophysics Data System (ADS)

    Kim, Changsoo; Kim, Dongseuk; Chun, Byong Sun; Moon, Kyoung-Woong; Hwang, Chanyong

    2018-05-01

    The spin Hall effect has attracted a lot of interest in spintronics because it offers the possibility of a faster switching route with an electric current than with a spin-transfer-torque device. Recently, fieldlike spin-orbit torque has been shown to play an important role in the magnetization switching mechanism. However, there is no simple method for observing the fieldlike spin-orbit torque efficiency. We suggest a method for measuring fieldlike spin-orbit torque using a linear change in the resonance field in spectra of direct-current (dc)-tuned spin-torque ferromagnetic resonance. The fieldlike spin-orbit torque efficiency can be obtained in both a macrospin simulation and in experiments by simply subtracting the Oersted field from the shifted amount of resonance field. This method analyzes the effect of fieldlike torque using dc in a normal metal; therefore, only the dc resistivity and the dimensions of each layer are considered in estimating the fieldlike spin-torque efficiency. The evaluation of fieldlike-torque efficiency of a newly emerging material by modulation of the resonance field provides a shortcut in the development of an alternative magnetization switching device.

  1. Structural Efficiency of Composite Struts for Aerospace Applications

    NASA Technical Reports Server (NTRS)

    Jegley, Dawn C.; Wu, K. Chauncey; McKenney, Martin J.; Oremont, Leonard

    2011-01-01

    The structural efficiency of carbon-epoxy tapered struts is considered through trade studies, detailed analysis, manufacturing and experimentation. Since some of the lunar lander struts are more highly loaded than struts used in applications such as satellites and telescopes, the primary focus of the effort is on these highly loaded struts. Lunar lander requirements include that the strut has to be tapered on both ends, complicating the design and limiting the manufacturing process. Optimal stacking sequences, geometries, and materials are determined and the sensitivity of the strut weight to each parameter is evaluated. The trade study results indicate that the most efficient carbon-epoxy struts are 30 percent lighter than the most efficient aluminum-lithium struts. Structurally efficient, highly loaded struts were fabricated and loaded in tension and compression to determine if they met the design requirements and to verify the accuracy of the analyses. Experimental evaluation of some of these struts demonstrated that they could meet the greatest Altair loading requirements in both tension and compression. These results could be applied to other vehicles requiring struts with high loading and light weight.

  2. Gas exchange and antioxidant activity in seedlings of C opaifera langsdorffii Desf. under different water conditions.

    PubMed

    Rosa, Derek B C J; Scalon, Silvana P Q; Cremon, Thais; Ceccon, Felipe; Dresch, Daiane M

    2017-01-01

    The aim of this study was to evaluate gas exchange, efficiency of the photosynthetic apparatus, and antioxidant activity in Copaifera langsdorffii Desf. The seedlings were cultivated under different conditions of water availability, in order to improve the utilization efficiency of available water resources. The seedlings were cultivated in four different water retention capacities (WRC- 25%, 50%, 75%, and 100%), and evaluated at four different time (T- 30, 60, 90, and 120 days). During the experimental period, seedlings presented the highest values for carboxylation efficiency of Rubisco (A/Ci), intrinsic water use efficiency (IWUE = A/gs), chlorophyll index, and stomatal opening, when grown in the substrate with 75% WRC, but the stomatal index (SI) was less the 25% WRC. The efficiency of photosystem II was not significantly altered by the treatments. Comparison between the extreme treatments in terms of water availability, represented by 25% and 100% WRC, represent stress conditions for the species. Water availability causes a high activity of antioxidant enzymes (superoxide dismutase, peroxidase, and catalase) in the plant.

  3. Objective Metric Based Assessments for Efficient Evaluation of Auditory Situation Awareness Characteristics of Tactical Communications and Protective Systems (TCAPS) and Augmented Hearing Protective Devices (HPDs)

    DTIC Science & Technology

    2015-11-30

    Assessments for Efficient Evaluation of Auditory Situation Awareness Characteristics of Tactical Communications and Protective Systems (TCAPS) and Augmented...Hearing Protective Devices (HPDs) W81XWH-13-C-0193 John G. Casali, Ph.D, CPE & Kichol Lee, Ph.D Auditory Systems Lab, Industrial and Systems ...Suite 1 JBSA Lackland, TX 78236-9908 Approved for public release: distribution unlimited. The Virginia Tech Auditory Systems Laboratory (ASL

  4. Evaluation of the Consolidation of Real Property Maintenance Activities (RPMA) in the U.S. Army Engineer Activity, Capital Area (USAEA, CA). Volume 2. Evaluation

    DTIC Science & Technology

    1990-03-01

    MANAGEMENT ................................... 62 Scope of Current Operations 62 Evolution of the Original RMD Plan 66 Financial Management Support Operations...Scope of Current Operations 76 Evolution of SMD From IPG Plan 78 SMD Support to RPMA 81 Efficiency of Supply Service 85 7 PROCUREMENT AND CONTRACTING...RPMA are to be realized. This chapter investigates these controls in terms of scope, evolution , operations (a functional assessment), and efficiency

  5. 76 FR 37344 - Technology Evaluation Process

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-27

    ...-NOA-0039] Technology Evaluation Process AGENCY: Office of Energy Efficiency and Renewable Energy... is an extension of a prior RFI seeking comment on a proposed commercial buildings technology... seeks comments and information related to a commercial buildings technology evaluation process. DOE is...

  6. 76 FR 30696 - Technology Evaluation Process

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-26

    ...-NOA-0039] Technology Evaluation Process AGENCY: Office of Energy Efficiency and Renewable Energy... (DOE) seeks comments and information related to a commercial buildings technology evaluation process... technologies for commercial buildings based on the voluntary submittal of product test data. The program would...

  7. Building Energy Asset Score for Architects

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Building Technologies Office

    2015-01-01

    The Building Energy Asset Score is a national standardized tool for evaluating the physical and structural energy efficiency of commercial and multifamily residential buildings. The Asset Score generates a simple energy efficiency rating that enables comparison among buildings, and identifies opportunities for users to invest in energy efficiency upgrades. It is web-based and free to use. This fact sheet discusses the value of the score for architects.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Building Technologies Office

    The Building Energy Asset Score is a national standardized tool for evaluating the physical and structural energy efficiency of commercial and multifamily residential buildings. The Asset Score generates a simple energy efficiency rating that enables comparison among buildings, and identifies opportunities for users to invest in energy efficiency upgrades. It is web-based and free to use. This fact sheet discusses the value of the score for energy services companies, engineers and green building consultants.

  9. The blind men and the elephant: the impact of context and scale in evaluating conflicts between plant hydraulic safety and efficiency

    Treesearch

    Frederick C. Meinzer; Katherine A. McCulloh; Barbara Lachenbruch; David R. Woodruff; Daniel M. Johnson

    2010-01-01

    Given the fundamental importance of xylem safety and efficiency for plant survival and fitness, it is not surprising that these are among the most commonly studied features of hydraulic architecture. However, much remains to be learned about the nature and universality of conflicts between hydraulic safety and efficiency. Although selection for suites of hydraulic...

  10. [Definition of quantum efficiency of X-ray detectors].

    PubMed

    Zelikman, M I

    2001-01-01

    Different definitions available in the literature on the quantum efficiency of X-ray detectors are presented and compared. The relationship of this parameter to spatial frequencies for quantum accounting receivers and energy accumulating ones is analyzed. A procedure is proposed for evaluating the quantum efficiency of the detectors in the area of zero spatial frequencies, which is rather simple and requires no special testing equipment.

  11. Effects of leader topping and branch pruning on efficiency of Douglas-fir cone harvesting with a tree shaker.

    Treesearch

    D.L. Copes

    1985-01-01

    In 1983, a study was conducted to evaluate the effects of leader topping and branch pruning on the efficiency to tree shaking to remove Douglas-fir (Pseudotsuga menziesii (Mirb.) Franco) cones. Removal efficiency for three topping and pruning treatments averaged 69 percent, whereas for the uncut control treatment it was 62 percent. The treatment...

  12. Evaluation of Advanced Stirling Convertor Net Heat Input Correlation Methods Using a Thermal Standard

    NASA Technical Reports Server (NTRS)

    Briggs, Maxwell; Schifer, Nicholas

    2011-01-01

    Test hardware used to validate net heat prediction models. Problem: Net Heat Input cannot be measured directly during operation. Net heat input is a key parameter needed in prediction of efficiency for convertor performance. Efficiency = Electrical Power Output (Measured) divided by Net Heat Input (Calculated). Efficiency is used to compare convertor designs and trade technology advantages for mission planning.

  13. Model Evaluation To Measuring Efficiencies of ICT Development In Indonesia Region Using DEA

    NASA Astrophysics Data System (ADS)

    Efendi, Syahril; Fadly Syahputra, M.; Anggia Muchtar, M.

    2018-01-01

    ICT Pura or digital city is a program designed by the Indonesian government with the main objective is to determine the level of readiness of each district and city in each province in the era of digital economy. It is necessarily to evaluate whether a city or a region that was successfully managing ICT better than other city and significantly contributes to the communities and living systems. Data envelopment analysis (DEA) is a well known technique to estimate efficiency and returns to scale through the construction of a best practice frontier, based on non-parametric mathematical programming approach. This paper addresses DEA BCC method to get index of efficiencies for all region in Indonesia covered by ICT Pura. Numerical result is given.

  14. Traditional versus rule-based programming techniques - Application to the control of optional flight information

    NASA Technical Reports Server (NTRS)

    Ricks, Wendell R.; Abbott, Kathy H.

    1987-01-01

    A traditional programming technique for controlling the display of optional flight information in a civil transport cockpit is compared to a rule-based technique for the same function. This application required complex decision logic and a frequently modified rule base. The techniques are evaluated for execution efficiency and implementation ease; the criterion used to calculate the execution efficiency is the total number of steps required to isolate hypotheses that were true and the criteria used to evaluate the implementability are ease of modification and verification and explanation capability. It is observed that the traditional program is more efficient than the rule-based program; however, the rule-based programming technique is more applicable for improving programmer productivity.

  15. Performance measurement for supply chain management and evaluation criteria determination for reverse supply chain management

    NASA Astrophysics Data System (ADS)

    Kongar, N. Elif

    2004-12-01

    Today, since customers are able to obtain similar-quality products for similar prices, the lead time has become the only preference criterion for most of the consumers. Therefore, it is crucial that the lead time, i.e., the time spent from the raw material phase till the manufactured good reaches the customer, is minimized. This issue can be investigated under the title of Supply Chain Management (SCM). An efficiently managed supply chain can lead to reduced response time for customers. To achieve this, continuous observation of supply chain efficiency, i.e., a constant performance evaluation of the current SCM is required. Widely used conventional performance measurement methods lack the ability to evaluate a SCM since the supply chain is a dynamic system that requires a more thorough and flexible performance measurement technique. Balanced Scorecard (BS) is an efficient tool for measuring the performance of dynamic systems and has a proven capability of providing the decision makers with the appropriate feedback data. In addition to SCM, a relatively new management field, namely reverse supply chain management (RSCM), also necessitates an appropriate evaluation approach. RSCM differs from SCM in many aspects, i.e., the criteria used for evaluation, the high level of uncertainty involved etc., not allowing the usage of identical evaluation techniques used for SCM. This study proposes a generic Balanced Scorecard to measure the performance of supply chain management while defining the appropriate performance measures for SCM. A scorecard prototype, ESCAPE, is presented to demonstrate the evaluation process.

  16. Sampling error in timber surveys

    Treesearch

    Austin Hasel

    1938-01-01

    Various sampling strategies are evaluated for efficiency in an interior ponderosa pine forest. In a 5760 acre tract, efficiency was gained by stratifying into quarter acre blocks and sampling randomly from within. A systematic cruise was found to be superior for volume estimation.

  17. Improving primary health care facility performance in Ghana: efficiency analysis and fiscal space implications.

    PubMed

    Novignon, Jacob; Nonvignon, Justice

    2017-06-12

    Health centers in Ghana play an important role in health care delivery especially in deprived communities. They usually serve as the first line of service and meet basic health care needs. Unfortunately, these facilities are faced with inadequate resources. While health policy makers seek to increase resources committed to primary healthcare, it is important to understand the nature of inefficiencies that exist in these facilities. Therefore, the objectives of this study are threefold; (i) estimate efficiency among primary health facilities (health centers), (ii) examine the potential fiscal space from improved efficiency and (iii) investigate the efficiency disparities in public and private facilities. Data was from the 2015 Access Bottlenecks, Cost and Equity (ABCE) project conducted by the Institute for Health Metrics and Evaluation. The Stochastic Frontier Analysis (SFA) was used to estimate efficiency of health facilities. Efficiency scores were then used to compute potential savings from improved efficiency. Outpatient visits was used as output while number of personnel, hospital beds, expenditure on other capital items and administration were used as inputs. Disparities in efficiency between public and private facilities was estimated using the Nopo matching decomposition procedure. Average efficiency score across all health centers included in the sample was estimated to be 0.51. Also, average efficiency was estimated to be about 0.65 and 0.50 for private and public facilities, respectively. Significant disparities in efficiency were identified across the various administrative regions. With regards to potential fiscal space, we found that, on average, facilities could save about GH₵11,450.70 (US$7633.80) if efficiency was improved. We also found that fiscal space from efficiency gains varies across rural/urban as well as private/public facilities, if best practices are followed. The matching decomposition showed an efficiency gap of 0.29 between private and public facilities. There is need for primary health facility managers to improve productivity via effective and efficient resource use. Efforts to improve efficiency should focus on training health workers and improving facility environment alongside effective monitoring and evaluation exercises.

  18. Evaluation of a time efficient immunization strategy for anti-PAH antibody development

    PubMed Central

    Li, Xin; Kaattari, Stephen L.; Vogelbein, Mary Ann; Unger, Michael A.

    2016-01-01

    The development of monoclonal antibodies (mAb) with affinity to small molecules can be a time-consuming process. To evaluate shortening the time for mAb production, we examined mouse antisera at different time points post-immunization to measure titer and to evaluate the affinity to the immunogen PBA (pyrene butyric acid). Fusions were also conducted temporally to evaluate antibody production success at various time periods. We produced anti-PBA antibodies 7 weeks post-immunization and selected for anti-PAH reactivity during the hybridoma screening process. Moreover, there were no obvious sensitivity differences relative to antibodies screened from a more traditional 18 week schedule. Our results demonstrate a more time efficient immunization strategy for anti-PAH antibody development that may be applied to other small molecules. PMID:27282486

  19. Measuring the efficiency of dental departments in medical centers: a nonparametric analysis approach.

    PubMed

    Wang, Su-Chen; Tsai, Chi-Cheng; Huang, Shun-Te; Hong, Yu-Jue

    2002-12-01

    Data envelopment analysis (DEA), a cross-sectional study design based on secondary data analysis, was used to evaluate the relative operational efficiency of 16 dental departments in medical centers in Taiwan in 1999. The results indicated that 68.7% of all dental departments in medical centers had poor performance in terms of overall efficiency and scale efficiency. All relatively efficient dental departments were in private medical centers. Half of these dental departments were unable to fully utilize available medical resources. 75.0% of public medical centers did not take full advantage of medical resources at their disposal. In the returns to scale, 56.3% of dental departments in medical centers exhibited increasing returns to scale, due to the insufficient scale influencing overall hospital operational efficiency. Public medical centers accounted for 77.8% of the institutions affected. The scale of dental departments in private medical centers was more appropriate than those in public medical centers. In the sensitivity analysis, the numbers of residents, interns, and published papers were used to assess teaching and research. Greater emphasis on teaching and research in medical centers has a large effect on the relative inefficiency of hospital operation. Dental departments in private medical centers had a higher mean overall efficiency score than those in public medical centers, and the overall efficiency of dental departments in non-university hospitals was greater than those in university hospitals. There was no information to evaluate the long-term efficiency of each dental department in all hospitals. A different combination of input and output variables, using common multipliers for efficiency value measurements in DEA, may help establish different pioneering dental departments in hospitals.

  20. "Knife to skin" time is a poor marker of operating room utilization and efficiency in cardiac surgery.

    PubMed

    Luthra, Suvitesh; Ramady, Omar; Monge, Mary; Fitzsimons, Michael G; Kaleta, Terry R; Sundt, Thoralf M

    2015-06-01

    Markers of operation room (OR) efficiency in cardiac surgery are focused on "knife to skin" and "start time tardiness." These do not evaluate the middle and later parts of the cardiac surgical pathway. The purpose of this analysis was to evaluate knife to skin time as an efficiency marker in cardiac surgery. We looked at knife to skin time, procedure time, and transfer times in the cardiac operational pathway for their correlation with predefined indices of operational efficiency (Index of Operation Efficiency - InOE, Surgical Index of Operational Efficiency - sInOE). A regression analysis was performed to test the goodness of fit of the regression curves estimated for InOE relative to the times on the operational pathway. The mean knife to skin time was 90.6 ± 13 minutes (23% of total OR time). The mean procedure time was 282 ± 123 minutes (71% of total OR time). Utilization efficiencies were highest for aortic valve replacement and coronary artery bypass grafting and least for complex aortic procedures. There were no significant procedure-specific or team-specific differences for standard procedures. Procedure times correlated the strongest with InOE (r = -0.98, p < 0.01). Compared to procedure times, knife to skin is not as strong an indicator of efficiency. A statistically significant linear dependence on InOE was observed with "procedure times" only. Procedure times are a better marker of OR efficiency than knife to skin in cardiac cases. Strategies to increase OR utilization and efficiency should address procedure times in addition to knife to skin times. © 2015 Wiley Periodicals, Inc.

Top