NASA Technical Reports Server (NTRS)
Tomes, Kristin; Long, David; Carter, Layne; Flynn, Michael
2007-01-01
The Vapor Phase Catalytic Ammonia. Removal (VPCAR) technology has been previously discussed as a viable option for. the Exploration Water Recovery System. This technology integrates a phase change process with catalytic oxidation in the vapor phase to produce potable water from exploration mission wastewaters. A developmental prototype VPCAR was designed, built and tested under funding provided by a National Research. Announcement (NRA) project. The core technology, a Wiped Film Rotating Device (WFRD) was provided by Water Reuse Technologies under the NRA, whereas Hamilton Sundstrand Space Systems International performed the hardware integration and acceptance test. of the system. Personnel at the-Ames Research Center performed initial systems test of the VPCAR using ersatz solutions. To assess the viability of this hardware for Exploration. Life Support (ELS) applications, the hardware has been modified and tested at the MSFC ECLS Test facility. This paper summarizes the hardware modifications and test results and provides an assessment of this technology for the ELS application.
CMIF ECLS system test findings
NASA Technical Reports Server (NTRS)
Schunk, Richard G.; Carrasquillo, Robyn L.; Ogle, Kathyrn Y.; Wieland, Paul O.; Bagdigian, Robert M.
1989-01-01
During 1987 three Space Station integrated Environmental Control and Life Support System (ECLSS) tests were conducted at the Marshall Space Flight Center (MSFC) Core Module Integration Facility (CMIF) as part of the MSFC ECLSS Phase II test program. The three tests ranged in duration from 50 to 150 hours and were conducted inside of the CMIF module simulator. The Phase II partial integrated system test configuration consisted of four regenerative air revitalization subsystems and one regenerative water reclamation subsystem. This paper contains a discussion of results and lessons learned from the Phase II test program. The design of the Phase II test configuration and improvements made throughout the program are detailed. Future plans for the MSFC CMIF test program are provided, including an overview of planned improvements for the Phase III program.
Space Station CMIF extended duration metabolic control test
NASA Technical Reports Server (NTRS)
Schunk, Richard G.; Bagdigian, Robert M.; Carrasquillo, Robyn L.; Ogle, Kathryn Y.; Wieland, Paul O.
1989-01-01
The Space Station Extended Duration Metabolic Control Test (EMCT) was conducted at the MSFC Core Module Integration Facility. The primary objective of the EMCT was to gather performance data from a partially-closed regenerative Environmental Control and Life Support (ECLS) system functioning under steady-state conditions. Included is a description of the EMCT configuration, a summary of events, a discussion of anomalies that occurred during the test, and detailed results and analysis from individual measurements of water and gas samples taken during the test. A comparison of the physical, chemical, and microbiological methods used in the post test laboratory analyses of the water samples is included. The preprototype ECLS hardware used in the test, providing an overall process description and theory of operation for each hardware item. Analytical results pertaining to a system level mass balance and selected system power estimates are also included.
Space Synthetic Biology Project
NASA Technical Reports Server (NTRS)
Howard, David; Roman, Monsi; Mansell, James (Matt)
2015-01-01
Synthetic biology is an effort to make genetic engineering more useful by standardizing sections of genetic code. By standardizing genetic components, biological engineering will become much more similar to traditional fields of engineering, in which well-defined components and subsystems are readily available in markets. Specifications of the behavior of those components and subsystems can be used to model a system which incorporates them. Then, the behavior of the novel system can be simulated and optimized. Finally, the components and subsystems can be purchased and assembled to create the optimized system, which most often will exhibit behavior similar to that indicated by the model. The Space Synthetic Biology project began in 2012 as a multi-Center effort. The purpose of this project was to harness Synthetic Biology principals to enable NASA's missions. A central target for application was to Environmental Control & Life Support (ECLS). Engineers from NASA Marshall Space Flight Center's (MSFC's) ECLS Systems Development Branch (ES62) were brought into the project to contribute expertise in operational ECLS systems. Project lead scientists chose to pursue the development of bioelectrochemical technologies to spacecraft life support. Therefore, the ECLS element of the project became essentially an effort to develop a bioelectrochemical ECLS subsystem. Bioelectrochemical systems exploit the ability of many microorganisms to drive their metabolisms by direct or indirect utilization of electrical potential gradients. Whereas many microorganisms are capable of deriving the energy required for the processes of interest (such as carbon dioxide (CO2) fixation) from sunlight, it is believed that subsystems utilizing electrotrophs will exhibit smaller mass, volume, and power requirements than those that derive their energy from sunlight. In the first 2 years of the project, MSFC personnel conducted modeling, simulation, and conceptual design efforts to assist the project in selecting the best approaches to the application of bioelectrochemical technologies to ECLS. Figure 1 shows results of simulation of charge transport in an experimental system. Figure 2 shows one of five conceptual designs for ECLS subsystems based on bioelectrochemical reactors. Also during the first 2 years, some work was undertaken to gather fundamental data (conductivities, overpotentials) relevant to the modeling efforts.
Analysis of the Korean Navy Selection Process for the Naval Post Graduate School
1988-06-01
OUTCOME OF ECL TESTING SCORE..........................54 C. OUTCOME OF TOEFL TESTING SCORE.......................55 D. PLOT OF NPS GRADE WITH ECL...TESTING SCORE..............55 E. PLOT OF NPS GRADE WIHT NA GRADE......................56 F. PLOT OF NPS GRADE WITH TOEFL TESTING SCORE............56...OF ECL TESTING SCORE ............. 30 Table S. EXPECTANCY TABLE OF NAG ............................ 31 Table 9. EXPECTANCY TABLE OF TOEFL TESTING SCORE
NASA Technical Reports Server (NTRS)
Williams, David E.
2011-01-01
The International Space Station (ISS) Node 1 Environmental Control and Life Support (ECLS) System is comprised of five subsystems: Atmosphere Control and Storage (ACS), Atmosphere Revitalization (AR), Fire Detection and Suppression (FDS), Temperature and Humidity Control (THC), and Water Recovery and Management (WRM). This paper will provide a summary of the Node 1 ECLS THC subsystem design and a detailed discussion of the ISS ECLS Acceptance Testing methodology utilized for this subsystem.The International Space Station (ISS) Node 1 Environmental Control and Life Support (ECLS) System is comprised of five subsystems: Atmosphere Control and Storage (ACS), Atmosphere Revitalization (AR), Fire Detection and Suppression (FDS), Temperature and Humidity Control (THC), and Water Recovery and Management (WRM). This paper will provide a summary of the Node 1 ECLS THC subsystem design and a detailed discussion of the ISS ECLS Acceptance Testing methodology utilized for this subsystem.
Space station ECLSS simplified integrated test
NASA Technical Reports Server (NTRS)
Schunk, Richard G.; Bagdigian, Robert M.; Carrasquillo, Robyn L.; Ogle, Kathyrn Y.; Wieland, Paul O.
1989-01-01
A discussion of the Space Station Simplified Integrated Test (SIT) was conducted. The first in a series of three integrated Environmental Control and Life Support (ECLS) system tests, the primary objectives of the SIT were to verify proper operation of ECLS subsystems functioning in an integrated fashion as well as to gather preliminary performance data for the partial ECLS system used in the test. A description of the SIT configuration, a summary of events, a discussion of anomalies that occurred during the test, and detailed results and analysis from individual measurements and water and gas samples taken during the test are included. The preprototype ECLS hardware used in the test is reported providing an overall process description and theory of operation for each hardware item.
Ge, Lei; Yan, Jixian; Song, Xianrang; Yan, Mei; Ge, Shenguang; Yu, Jinghua
2012-02-01
In this work, electrochemiluminescence (ECL) immunoassay was introduced into the recently proposed microfluidic paper-based analytical device (μPADs) based on directly screen-printed electrodes on paper for the very first time. The screen-printed paper-electrodes will be more important for further development of this paper-based ECL device in simple, low-cost and disposable application than commercialized ones. To further perform high-performance, high-throughput, simple and inexpensive ECL immunoassay on μPAD for point-of-care testing, a wax-patterned three-dimensional (3D) paper-based ECL device was demonstrated for the very first time. In this 3D paper-based ECL device, eight carbon working electrodes including their conductive pads were screen-printed on a piece of square paper and shared the same Ag/AgCl reference and carbon counter electrodes on another piece of square paper after stacking. Using typical tris-(bipyridine)-ruthenium (Ⅱ) - tri-n-propylamine ECL system, the application test of this 3D paper-based ECL device was performed through the diagnosis of four tumor markers in real clinical serum samples. With the aid of a facile device-holder and a section-switch assembled on the analyzer, eight working electrodes were sequentially placed into the circuit to trigger the ECL reaction in the sweeping range from 0.5 to 1.1 V at room temperature. In addition, this 3D paper-based ECL device can be easily integrated and combined with the recently emerging paper electronics to further develop simple, sensitive, low-cost, disposable and portable μPAD for point-of-care testing, public health and environmental monitoring in remote regions, developing or developed countries. Copyright © 2011 Elsevier Ltd. All rights reserved.
Yang, Hongmei; Kong, Qingkun; Wang, Shaowei; Xu, Jinmeng; Bian, Zhaoquan; Zheng, Xiaoxiao; Ma, Chao; Ge, Shenguang; Yu, Jinghua
2014-11-15
In this paper, a pen-on-paper electrochemiluminescence (PoP-ECL) device was entirely hand drawn and written in commercially available crayon and pencil in turn for the first time, and a constant potential-triggered sandwich-type immunosensor was introduced into the PoP-ECL device to form a low-cost ECL immunodevice proof. Each PoP-ECL device contained a hydrophilic paper channel and two PoP electrodes, and the PoP-ECL device was produced as follows: crayon was firstly used to draw hydrophobic regions on pure cellulose paper to create the hydrophilic paper channels followed with a baking treatment, and then a 6B-type black pencil with low resistivity was applied for precision writing, as the PoP electrodes, across the hydrophilic paper channel. For further point-of-care testing, a portable, low-cost rechargeable battery was employed as the power source to provide constant potential to the PoP electrodes to trigger the ECL. Using Carbohydrate antigen 199 as model analyte, this PoP-ECL immunodevice showed a good linear response range from 0.01-200 U mL(-1) with a detection limit of 0.0055 U mL(-1), a high sensitivity and stability. The proposed PoP-ECL immunodevice could be used in point-of-care testing of other tumor markers for remote regions and developing countries. Copyright © 2014 Elsevier B.V. All rights reserved.
Sosenko, Jay M; Yu, Liping; Skyler, Jay S; Krischer, Jeffrey P; Gottlieb, Peter A; Boulware, David; Miao, Dongmei; Palmer, Jerry P; Steck, Andrea K
2017-03-01
Electrochemiluminescence (ECL) assays have shown promise for enhancing the prediction of type 1 diabetes (T1D) with autoantibodies. We thus studied relatives of T1D patients to determine whether ECL assays can be used to refine risk assessments for T1D among individuals either positive for single GADA or single mIAA autoantibodies. TrialNet Pathway to Prevention (PTP) study participants with either GADA or mIAA single autoantibodies were tested for ECL positivity during their participation in the TrialNet PTP study. Those ECL positive (ECL + ) were compared with those ECL negative (ECL - ) for conversion to multiple autoantibodies, 6-month glycemic progression (PS6M), and the progression to T1D. The progression to multiple autoantibodies was significantly higher for those GADA/ECL + (n = 107) than those GADA/ECL - (n = 78) (P = 0.001) and for those mIAA/ECL + (n = 24) than those mIAA/ECL - (n = 63) (P < 0.001). The hazard ratios with 95% confidence intervals were 3.42 (1.58-7.39; P < 0.01) for GADA and 8.15 (3.02-22.00; P < 0.001) for mIAA. GADA/ECL + and mIAA/ECL + participants had significantly higher PS6M values than their ECL - counterparts (P = 0.001 for GADA and P = 0.009 for mIAA). Of those GADA/ECL + , 14% progressed to T1D; of those mIAA/ECL + , 17% progressed to T1D. Only 1 individual (positive for GADA) of the 141 who was ECL - progressed to T1D (median follow-up: 5 years). ECL measurements appear to have utility for natural history studies and prevention trials of individuals with single autoantibodies. Those ECL + are at appreciable risk for developing multiple autoantibodies and for glycemic progression toward T1D, whereas those ECL - are at very low risk.
NASA Technical Reports Server (NTRS)
Williams, David E.
2009-01-01
The International Space Station (ISS) Node 1 Environmental Control and Life Support (ECLS) System is comprised of five subsystems: Atmosphere Control and Supply (ACS), Atmosphere Revitalization (AR), Fire Detection and Suppression (FDS), Temperature and Humidity Control (THC), and Water Recovery and Management (WRM). This paper provides a summary of the Node 1 ECLS ACS subsystem design and a detailed discussion of the ISS ECLS Acceptance Testing methodology utilized for that subsystem.
NASA Astrophysics Data System (ADS)
Deng, Yanan; Chang, Quanying; Yin, Kai; Liu, Chengbin; Wang, Ying
2017-10-01
A highly stable and effective electrochemiluminescence (ECL) sensing system of cadmium sulfide nanowires/reduced graphene oxide (CdS NWS/rGO) hybrid is presented for supersensitive detection of pentachlorophenol (PCP). CdS nanowire is for the first time exploited in ECL sensing. The rGO served as both ECL signal amplifier and immobilization platform, can perfectly enhance the ECL intensity and stability of the sensing system. With S2O82- as coreactant, the ECL signal can be significantly quenched by the addition of PCP. The established ECL sensing system presents a wider linear range from 1.0 × 10-14 to 1.0 × 10-8 M and a much low detection limit of 2 × 10-15 M under the optimum test conditions (e.g., pH 7.0 and 100 mM S2O82-). Furthermore, the ECL sensing system displays a good selectivity for PCP detection. The practicability of the ECL sensing system in real water sample shows that this system could be promisingly applied in the analytical detection of PCP in real water environments.
The SLS Stages Intertank Structural Test Assembly (STA) arrives at MSFC
2018-03-08
The SLS Stages Intertank Structural Test Assembly (STA) is rolling off the NASA Pegasus Barge at the MSFC Dock enroute to the MSFC 4619 Load Test Annex test facility for qualification testing via MSFC West Test Area. STA approaches Test Stand 4693, SLS LH2 test Stand, on way to Bldg. 4619
ERIC Educational Resources Information Center
Cimpian, Joseph R.; Lubienski, Sarah T.; Timmer, Jennifer D.; Makowski, Martha B.; Miller, Emily K.
2016-01-01
Studies using data from the Early Childhood Longitudinal Study-Kindergarten Class of 1998-1999 (ECLS-K:1999) revealed gender gaps in mathematics achievement and teacher perceptions. However, recent evidence suggests that gender gaps have closed on state tests, raising the question of whether such gaps are absent in the ECLS-K:2011 cohort.…
NASA Technical Reports Server (NTRS)
Williams, David E.
2008-01-01
The International Space Station (ISS) Pressurized Mating Adapters (PMAs) Environmental Control and Life Support (ECLS) System is comprised of three subsystems: Atmosphere Control and Supply (ACS), Temperature and Humidity Control (THC), and Water Recovery and Management (WRM). PMAs 1 and 2 flew to ISS on Flight 2A and Pressurized Mating Adapter (PMA) 3 flew to ISS on Flight 3A. This paper provides a summary of the PMAs ECLS design and a detailed discussion of the ISS ECLS Acceptance Testing methodologies utilized for the PMAs.
Fouts, Alexandra; Pyle, Laura; Yu, Liping; Miao, Dongmei; Michels, Aaron; Krischer, Jeffrey; Sosenko, Jay; Gottlieb, Peter
2016-01-01
OBJECTIVE To explore whether electrochemiluminescence (ECL) assays can help improve prediction of time to type 1 diabetes in the TrialNet autoantibody-positive population. RESEARCH DESIGN AND METHODS TrialNet subjects who were positive for one or more autoantibodies (microinsulin autoantibody, GAD65 autoantibody [GADA], IA-2A, and ZnT8A) with available ECL-insulin autoantibody (IAA) and ECL-GADA data at their initial visit were analyzed; after a median follow-up of 24 months, 177 of these 1,287 subjects developed diabetes. RESULTS Univariate analyses showed that autoantibodies by radioimmunoassays (RIAs), ECL-IAA, ECL-GADA, age, sex, number of positive autoantibodies, presence of HLA DR3/4-DQ8 genotype, HbA1c, and oral glucose tolerance test (OGTT) measurements were all significantly associated with progression to diabetes. Subjects who were ECL positive had a risk of progression to diabetes within 6 years of 58% compared with 5% for the ECL-negative subjects (P < 0.0001). Multivariate Cox proportional hazards models were compared, with the base model including age, sex, OGTT measurements, and number of positive autoantibodies by RIAs. The model with positivity for ECL-GADA and/or ECL-IAA was the best, and factors that remained significantly associated with time to diabetes were area under the curve (AUC) C-peptide, fasting C-peptide, AUC glucose, number of positive autoantibodies by RIAs, and ECL positivity. Adding ECL to the Diabetes Prevention Trial risk score (DPTRS) improved the receiver operating characteristic curves with AUC of 0.83 (P < 0.0001). CONCLUSIONS ECL assays improved the ability to predict time to diabetes in these autoantibody-positive relatives at risk for developing diabetes. These findings might be helpful in the design and eligibility criteria for prevention trials in the future. PMID:27456836
Fouts, Alexandra; Pyle, Laura; Yu, Liping; Miao, Dongmei; Michels, Aaron; Krischer, Jeffrey; Sosenko, Jay; Gottlieb, Peter; Steck, Andrea K
2016-10-01
To explore whether electrochemiluminescence (ECL) assays can help improve prediction of time to type 1 diabetes in the TrialNet autoantibody-positive population. TrialNet subjects who were positive for one or more autoantibodies (microinsulin autoantibody, GAD65 autoantibody [GADA], IA-2A, and ZnT8A) with available ECL-insulin autoantibody (IAA) and ECL-GADA data at their initial visit were analyzed; after a median follow-up of 24 months, 177 of these 1,287 subjects developed diabetes. Univariate analyses showed that autoantibodies by radioimmunoassays (RIAs), ECL-IAA, ECL-GADA, age, sex, number of positive autoantibodies, presence of HLA DR3/4-DQ8 genotype, HbA1c, and oral glucose tolerance test (OGTT) measurements were all significantly associated with progression to diabetes. Subjects who were ECL positive had a risk of progression to diabetes within 6 years of 58% compared with 5% for the ECL-negative subjects (P < 0.0001). Multivariate Cox proportional hazards models were compared, with the base model including age, sex, OGTT measurements, and number of positive autoantibodies by RIAs. The model with positivity for ECL-GADA and/or ECL-IAA was the best, and factors that remained significantly associated with time to diabetes were area under the curve (AUC) C-peptide, fasting C-peptide, AUC glucose, number of positive autoantibodies by RIAs, and ECL positivity. Adding ECL to the Diabetes Prevention Trial risk score (DPTRS) improved the receiver operating characteristic curves with AUC of 0.83 (P < 0.0001). ECL assays improved the ability to predict time to diabetes in these autoantibody-positive relatives at risk for developing diabetes. These findings might be helpful in the design and eligibility criteria for prevention trials in the future. © 2016 by the American Diabetes Association.
The SLS Stages Intertank Structural Test Assembly (STA) arrives at MSFC
2018-03-08
The SLS Stages Intertank Structural Test Assembly (STA) is rolling off the NASA Pegasus Barge at the MSFC Dock enroute to the MSFC 4619 Load Test Annex test facility for qualification testing via MSFC West Test Area. Historic Saturn 1-C test stand on far left, blockhouse 4670 on far right, SLS LH2 test stand, 4693, in center.
The SLS Stages Intertank Structural Test Assembly (STA) arrives at MSFC
2018-03-08
The SLS Stages Intertank Structural Test Assembly (STA) is rolling off the NASA Pegasus Barge at the MSFC Dock enroute to the MSFC 4619 Load Test Annex test facility for qualification testing via MSFC West Test Area. STA enters West Test Area from intersection of Dodd and Saturn roads. Onlookers take photos with Historic Dynamic Test Stand in background.
ERIC Educational Resources Information Center
Berger, Louis S.; And Others
This report analyzes a two-step program designed to achieve security in the administration of the English Comprehension Level (ECL) test given by the Defense Language Institute. Since the ECL test score is the basis for major administrative and academic decisions, there is great motivation for performing well, and student test compromise is…
Sugiura, Aya; Iwahara, Kunihiro; Suga, Yasuyuki; Uchiyama, Sachinori; Maekawa, Masato
2012-04-01
We compared the ECLusys HIV combi assay (ECL HIV Ag/Ab) to the Lumipulse Forte (LPf HIV 1/2 Ab) and HISCL (HIS HIV 1/2 Ab) assays. In a dilution sensitivity test using dilution panels of WHO HIV antibody international reference panel (HIV-1 Subtype A, B, C, E, HIV-1 Group O, HIV-2) and HIV-1/2 Ab CE marked material(HIV-1, HIV-2) parent specimens, the ECL assay enabled detection at a higher level of sensitivity than either the LPf assay or the HIS assay for all dilution panels. In an early detection test in the early phase of infection in which a BBI HIV seroconversion panel was used, the ECL assay enabled detection 7 days after initial blood sample collection, whereas the LPf and HIS assays enabled detection after 27 days. In a specificity test using high RF positive specimens (n=33), pregnancy specimens (n=35), cytomegalovirus antibody positive specimens (n=36), and high M protein positive specimens (n=21) that were confirmed negative for HIV-1/2 antibodies by the LPf assay, negative results were obtained for all specimens on both the ECL assay and the HIS assay. In a correlation test using routinely collected clinical specimens (n=121), including positive stock specimens, the ECL and HIS assays demonstrated the highest agreement rate 98.3%. The above results confirmed that the fourth-generation reagent ECL assay, which simultaneously detects both HIV-1/2 antibodies and p24 antigens, is both highly sensitive and specific, and is a suitable assay for use in routine testing.
The SLS Stages Intertank Structural Test Assembly (STA) arrives at MSFC
2018-03-06
The SLS Stages Intertank Structural Test Assembly (STA) is rolling off the NASA Pegasus Barge at the MSFC Dock enroute to the MSFC 4619 Load Test Annex test facility for qualification testing. Members of MSFC Logistics Office and Move Team members gather for last minute instructions and safety briefing before off-loading STA hardware.
Yu, Liping; Skyler, Jay S.; Krischer, Jeffrey P.; Gottlieb, Peter A.; Boulware, David; Miao, Dongmei; Palmer, Jerry P.; Steck, Andrea K.
2017-01-01
Abstract Background: Electrochemiluminescence (ECL) assays have shown promise for enhancing the prediction of type 1 diabetes (T1D) with autoantibodies. We thus studied relatives of T1D patients to determine whether ECL assays can be used to refine risk assessments for T1D among individuals either positive for single GADA or single mIAA autoantibodies. Subjects and Methods: TrialNet Pathway to Prevention (PTP) study participants with either GADA or mIAA single autoantibodies were tested for ECL positivity during their participation in the TrialNet PTP study. Those ECL positive (ECL+) were compared with those ECL negative (ECL−) for conversion to multiple autoantibodies, 6-month glycemic progression (PS6M), and the progression to T1D. Results: The progression to multiple autoantibodies was significantly higher for those GADA/ECL+ (n = 107) than those GADA/ECL− (n = 78) (P = 0.001) and for those mIAA/ECL+ (n = 24) than those mIAA/ECL− (n = 63) (P < 0.001). The hazard ratios with 95% confidence intervals were 3.42 (1.58–7.39; P < 0.01) for GADA and 8.15 (3.02–22.00; P < 0.001) for mIAA. GADA/ECL+ and mIAA/ECL+ participants had significantly higher PS6M values than their ECL− counterparts (P = 0.001 for GADA and P = 0.009 for mIAA). Of those GADA/ECL+, 14% progressed to T1D; of those mIAA/ECL+, 17% progressed to T1D. Only 1 individual (positive for GADA) of the 141 who was ECL− progressed to T1D (median follow-up: 5 years). Conclusion: ECL measurements appear to have utility for natural history studies and prevention trials of individuals with single autoantibodies. Those ECL+ are at appreciable risk for developing multiple autoantibodies and for glycemic progression toward T1D, whereas those ECL− are at very low risk. PMID:28177779
Sugiura, Aya; Iwahara, Kunihiro; Suga, Yasuyuki; Uchiyama, Sachinori; Maekawa, Masato
2012-02-01
We compared the ECLusys HBsAgII (ECL HBsAg) assay to the Lumipulse Forte (LPf HBsAg) and HISCL (HIS HBsAg) assays. Measurement of dilution panels for which the WHO HBsAg international reference panel was the parent specimen revealed that the ECL and HIS assays enabled detection to a theoretical level of 0.04 IU/mL, whereas the LPf assay enabled detection to a level of 0.08 IU/mL. In a specificity test using high RF positive specimens (n = 33), pregnancy specimens (n = 35), cytomegalovirus antibody positive specimens (n = 36), and high M protein positive specimens (n = 21) that were confirmed negative for HBsAg by the LPf assay, negative results were obtained for all specimens on the HIS assay, but the ECL assay yielded a positive result for one of the high RF positive specimens. This individual was suggested on further testing to be an HBV carrier who was strongly positive for HBc antibody. In HBsAg mutants detection test, the detection rate was 92.3% with the ECL assay and 69.2% with the HIS assay. In a correlation test using routinely collected clinical specimens (n = 155), including positive stock specimens, aside from the one case where the LPf assay gave a negative result but both the ECL and HIS assays gave positive results, all of the results were consistent for all specimens. The above results confirmed that the ECL assay is both highly sensitive and specific, and also enables a high rate of HBsAg mutant detection.
The SLS Stages Intertank Structural Test Assembly (STA) arrives at MSFC.
2018-03-06
The SLS Stages Intertank Structural Test Assembly (STA) is rolling off the NASA Pegasus Barge at the MSFC Dock enroute to the MSFC 4619 Load Test Annex test facility for qualification testing. STA emerges from Barge Pegasus.
Shekar, Kiran; Fung, Yoke L; Diab, Sara; Mullany, Daniel V; McDonald, Charles I; Dunster, Kimble R; Fisquet, Stephanie; Platts, David G; Stewart, David; Wallis, Steven C; Smith, Maree T; Roberts, Jason A; Fraser, John F
2012-06-01
Extracorporeal life support (ECLS) is a lifesaving technology that is being increasingly used in patients with severe cardiorespiratory failure. However, ECLS is not without risks. The biosynthetic interface between the patient and the circuit can significantly alter inflammation, coagulation, pharmacokinetics and disposition of trace elements. The relative contributions of the pump, disease and patient in propagating these alterations are difficult to quantify in critically ill patients with multiple organ failure. To design a model where the relevance of individual components could be assessed, in isolation and in combination. Four ECLS models were developed and tested - an in-vitro simulated ECLS circuit; and ECLS in healthy sheep, sheep with acute lung injury (ALI), and sheep with ALI together with transfusion of old or new blood. Successful design of in-vitro and in-vivo models. We successfully conducted multiple experiments in the simulated circuits and ECLS runs in healthy and ALI sheep. We obtained preliminary data on inflammation, coagulation, histology, pharmacokinetics and trace element disposition during ECLS. The establishment of in-vitro and in-vivo models provides a powerful means for enhancing knowledge of the pathophysiology associated with ECLS and identification of key factors likely to influence patient outcomes. A clearer description of the contribution of disease and therapeutic interventions may allow improved design of equipment, membranes, medicines and physiological goals for improved patient care.
Sugiura, Aya; Iwahara, Kunihiro; Suga, Yasuyuki; Uchiyama, Sachinori; Maekawa, Masato
2012-09-01
We compared the ECLusys Anti-HCV (ECL) reagent to the Lumipulse f (LPf) and HISCL (HIS) HCV assays. In a correlation test using 210 routine clinical specimens measured using the Lumipulse method (96 positive and 114 negative), most of the results were consistent for all specimens. In a dilution sensitivity test using three different routine positive specimens, the ECL assay enabled detection at higher levels of sensitivity than either the LPf or the HIS assay. Moreover, when the distribution of the cut-off index (C.O.I.) values of the routine LPf negative specimens were compared to those on the ECL and HIS assays, it was found that on the ECL assay, most of the specimens had cut-off index values < 0.1, indicating a more clear-cut distribution. In a specificity test using high RF positive specimens(n = 33), pregnancy specimens (n = 35), cytomegalovirus (CMV) antibody positive specimens (n = 36), and high M protein positive specimens (n = 21), the ECL assay yielded positive results for a CMV antibody positive specimen and three high M protein positive specimens. Further testing using samples from the same patients collected on different days than these four samples resulted in a second positive result for the CMV positive specimen, and single antigen measurement yielded a Core/NS3 positive result, as well, suggesting past infection. However, since negative results were obtained for the three M protein positive specimens, the possibility of this being a ECLusys non-specific reaction could not be ruled out. The above results confirmed that the ECL assay provides superior fundamental performance, and possesses test performance nearly identical to that of the existing measurement methods that are widely used at a large number of facilities, and would therefore be a suitable assay for use in routine HCV antibody screening.
Cycom 977-2 Composite Material: Impact Test Results (workshop presentation)
NASA Technical Reports Server (NTRS)
Engle, Carl; Herald, Stephen; Watkins, Casey
2005-01-01
Contents include the following: Ambient (13A) tests of Cycom 977-2 impact characteristics by the Brucenton and statistical method at MSFC and WSTF. Repeat (13A) tests of tested Cycom from phase I at MSFC to expended testing statistical database. Conduct high-pressure tests (13B) in liquid oxygen (LOX) and GOX at MSFC and WSTF to determine Cycom reaction characteristics and batch effect. Conduct expended ambient (13A) LOX test at MSFC and high-pressure (13B) testing to determine pressure effects in LOX. Expend 13B GOX database.
The SLS Stages Intertank Structural Test Assembly (STA) arrives at MSFC
2018-03-06
The SLS Stages Intertank Structural Test Assembly (STA) is rolling off the NASA Pegasus Barge at the MSFC Dock enroute to the MSFC 4619 Load Test Annex test facility for qualification testing. STA hardware completely free of barge and flanked by tug boats.
Materials Properties Research at MSFC
NASA Technical Reports Server (NTRS)
Presson, Joan B.; Burdine, Robert (Technical Monitor)
2002-01-01
MSFC is currently planning, organizing and directing test coupon fabrication and subsequent CTE testing for two mirror materials of specific interest to the AMSD and NGST programs, Beryllium 0-30H (Be 0-30H) and Ultra Low Expansion glass (ULE). The ULE test coupons are being fabricated at MSFC from AMSD core residuals provided by Kodak, The Be 0-30H test coupons are being fabricated at Brush Wellman using residuals from the SBMD. Both sets of test coupons will be sent to a test vendor selected through the NASA competitive proposal process with the test results being provided by written report to MSFC by the end of the fiscal year. The test results will become model input data for the AMSD analysts, both MSFC and contractor, providing an enhancement to the historical CTE data currently available.
1965-01-01
Workers at the Marshall Space Flight Center's (MSFC) Dynamic Test Stand install S-IB-200D, a dynamic test version of the Saturn IB launch vehicle's first stage, on January 11, 1965. MSFC Test Laboratory persornel assembled a complete Saturn IB to test the launch vehicle's structural soundness. Developed by the MSFC as an interim vehicle in MSFC's "building block" approach to the Saturn rocket development, the Saturn IB utilized Saturn I technology to further develop and refine the larger boosters and the Apollo spacecraft capabilities required for the manned lunar missions.
Walker, M A; Steinheimer, D N; Weir, V A; Homco, L D; Green, R W; Morris, E L; Hess, M E
1999-01-01
Portal radiographs, radiographs made to document the accuracy of radiotherapy treatment fields, are typically of poor image contrast. Recently, a new portal film and screened-cassette system was marketed, the Kodak EC-L system, with the claim of greatly improved image contrast. This new EC-L system was tested on a canine cadaver exposed to Cobalt-60 teletherapy gamma radiation, and image quality was compared to earlier marketed Kodak portal film products. The EC-L system was found to provide portal images of improved contrast/quality.
Procedures for Empirical Determination of En-Route Criterion Levels.
ERIC Educational Resources Information Center
Moncrief, Michael H.
En-route Criterion Levels (ECLs) are defined as decision rules for predicting pupil readiness to advance through an instructional sequence. This study investigated the validity of present ELCs in an individualized mathematics program and tested procedures for empirically determining optimal ECLs. Retest scores and subsequent progress were…
Gao, Hongfang; Wang, Xiaofei; Li, Man; Qi, Honglan; Gao, Qiang; Zhang, Chengxiao
2017-12-15
A proximity hybridization-regulated electrogenerated chemiluminescence (PLA-ECL) bioassay was developed for the detection of α-fetoprotein (AFP) on basis of the sensitization of gold nanoparticles (AuNPs) and target-induced quenching mechanism. Ru(bpy) 3 2+ was used as ECL signal while ferrocene (Fc) was used as ECL quencher. Ru(bpy) 3 2+ was electrostatically adsorbed into the AuNPs/Nafion film prepared by casting the mixture of Nafion and AuNPs onto the surface of glassy carbon electrode (GCE) to form an ECL platform (Ru(bpy) 3 2+ /AuNPs/Nafion/GCE), which displayed strong ECL emissions. A recognition platform was fabricated by self-assembling a capture DNA via thiol-gold bond on the surface of Ru(bpy) 3 2+ /AuNPs/Nafion/GCE. After sandwich immunoassay and proximity hybridization assay among capture DNA, AFP, a pair of antibody-oligonucleotide conjugates and a signal probe (DNA-Fc), Fc in DNA-Fc was brought close to the surface of electrode in conjunction with target induced ECL quenching. The ECL intensity decreased with the increasing concentration of the AFP and AFP was monitored with a linear range of 0.05-50ng/mL along with a detection limit of 0.04ng/mL. The ECL bioassay is successfully applied to the detection of AFP in serum samples with one-step recognition, short operating time and good accuracy. This method displays great potential for point-of-care testing and commercial application. Copyright © 2017 Elsevier B.V. All rights reserved.
Major, Terry C; Handa, Hitesh; Annich, Gail M; Bartlett, Robert H
2014-01-01
Hemocompatibility is the goal for any biomaterial contained in extracorporeal life supporting (ECLS) medical devices. The hallmarks for hemocompatibility include nonthrombogenicity, platelet preservation and maintained platelet function. Both in vitro and in vivo assays testing for compatibility of the blood/biomaterial interface have been used over the last several decades to ascertain if the biomaterial used in medical tubing and devices will require systemic anticoagulation for viability. Over the last 50 years systemic anticoagulation with heparin has been the gold standard in maintaining effective ECLS. However, the biomaterial that maintains effective ECLS without the use of any systemic anticoagulant has remained elusive. In this review, the in vivo 4-h rabbit thrombogenicity model genesis will be described with emphasis on biomaterials that may require no systemic anticoagulation for ECLS longevity. These novel biomaterials may improve extracorporeal circulation (ECC) hemocompatibility by preserving near resting physiology of the major blood components, the platelets and monocytes. The rabbit ECC model provides a complete assessment of biomaterial interactions with the intrinsic coagulation players, the circulating platelet and monocytes. This total picture of blood/biomaterial interaction suggests that this rabbit thrombogenicity model could provide a standardization for biomaterial hemocompatibility testing. PMID:24934500
1960-01-01
Marshall Space Flight Center (MSFC) workers hoist a dynamic test version of the S-IVB stage, the Saturn IB launch vehicle's second stage, into the Center's Dynamic Test Stand on January 18, 1965. MSFC Test Laboratory persornel assembled a complete Saturn IB to test the launch vehicle's structural soundness. Developed by the MSFC as an interim vehicle in MSFC's "building block" approach to the Saturn rocket development, the Saturn IB utilized Saturn I technology to further develop and refine the larger boosters and the Apollo spacecraft capabilities required for the manned lunar missions.
NASA Technical Reports Server (NTRS)
Williams, David E.; Lewis, John F.; Gentry, Gregory
2003-01-01
The International Space Station (ISS) Environmental Control and Life Support (ECLS) system includes regenerative and non-regenerative technologies that provide the basic life support functions to support the crew, while maintaining a safe and habitable shirtsleeve environment. This paper provides a summary of the ECLS System On-Orbit Station Development Test Objective (SDTO) status from the start of assembly until the end of February 2003.
AXAF-1 high-resolution mirror assembly image model and comparison with x-ray ground-test image
NASA Astrophysics Data System (ADS)
Zissa, David E.
1999-09-01
The completed High Resolution Mirror Assembly (HRMA) of the Advanced X-ray Astrophysics Facility - Imaging (AXAF-I) was tested at the X-ray Calibration Facility (XRCF) at the NASA- Marshall Space Flight Center (MSFC) in 1997. The MSFC image model was developed during the development of AXAF-I. The MSFC model is a detailed ray-trace model of the as-built HRMA optics and the XRCF teste conditions. The image encircled-energy distributions from the model are found to general agree well with XRCF test data nd the preliminary Smithsonian Astrophysical Observatory (SAO) model. MSFC model effective-area result generally agree with those of the preliminary SAO model. Preliminary model effective-area results were reported by SAO to be approximately 5-13 percent above initial XRCF test results. The XRCF test conditions are removed from the MSFC ray-trace model to derive an on-orbit prediction of the HRMA image.
Llena, C; Leyda, A; Forner, L; Garcet, S
2015-03-01
An investigation was conducted in a population of paediatric patients with a high risk of caries in order to assess the association between caries history (CH) and the number of early carious lesions (ECLs) and the frequency and timing of cariogenic food and beverage intake, sugar-containing medication, the frequency and efficacy of tooth brushing, and the use of topical fluorides. Study design: descriptive study. One hundred children aged 6-15 years with≥ ECL of a permanent tooth and not enrolled in any dental health educational or preventive programme were selected. For diagnosis it was used an explorer according to the ICDAS II criteria. The participants completed a closed-list questionnaire on the frequency and timing of cariogenic food intake. There was a nonsignificant tendency to present more ECLs and a greater CH among patients who consumed cariogenic foods and beverages. A significant relationship (p<0.05) was observed between cariogenic beverages and the number of ECL or CH. Using the number of ECLs as dependent variable, regular fluoridated rinses (p=0.003), frequent sugar-containing medication (p=0.007), and cariogenic beverage consumption (p=0.024) were identified as explanatory parameters in the linear regression model. The Student t-test was used to compare ECL and CH with dietetic factors, fluoridated rinses, sugar- containing medicines, and the frequency and efficacy of tooth brushing. Linear regression analysis correlated the number of ECLs to the mentioned explanatory variables. The frequent consumption of sugary beverages and medications, and failure to regularly use fluoridated rinses, were positively correlated to an increased number of ECLs in patients with a high prevalence of caries.
International Space Station ECLSS Technical Task Agreement Summary Report
NASA Technical Reports Server (NTRS)
Ray, C. D. (Compiler); Salyer, B. H. (Compiler)
1999-01-01
This Technical Memorandum provides a summary of current work accomplished under Technical Task Agreement (TTA) by the Marshall Space Flight Center (MSFC) regarding the International Space Station (ISS) Environmental Control and Life Support System (ECLSS). Current activities include ECLSS component design and development, computer model development, subsystem/integrated system testing, life testing, and general test support provided to the ISS program. Under ECLSS design, MSFC was responsible for the six major ECLSS functions, specifications and standard, component design and development, and was the architectural control agent for the ISS ECLSS. MSFC was responsible for ECLSS analytical model development. In-house subsystem and system level analysis and testing were conducted in support of the design process, including testing air revitalization, water reclamation and management hardware, and certain nonregenerative systems. The activities described herein were approved in task agreements between MSFC and NASA Headquarters Space Station Program Management Office and their prime contractor for the ISS, Boeing. These MSFC activities are in line to the designing, development, testing, and flight of ECLSS equipment planned by Boeing. MSFC's unique capabilities for performing integrated systems testing and analyses, and its ability to perform some tasks cheaper and faster to support ISS program needs, are the basis for the TTA activities.
Extracorporeal Life Support in Critically Ill Adults
Muratore, Christopher S.
2014-01-01
Extracorporeal life support (ECLS) has become increasingly popular as a salvage strategy for critically ill adults. Major advances in technology and the severe acute respiratory distress syndrome that characterized the 2009 influenza A(H1N1) pandemic have stimulated renewed interest in the use of venovenous extracorporeal membrane oxygenation (ECMO) and extracorporeal carbon dioxide removal to support the respiratory system. Theoretical advantages of ECLS for respiratory failure include the ability to rest the lungs by avoiding injurious mechanical ventilator settings and the potential to facilitate early mobilization, which may be advantageous for bridging to recovery or to lung transplantation. The use of venoarterial ECMO has been expanded and applied to critically ill adults with hemodynamic compromise from a variety of etiologies, beyond postcardiotomy failure. Although technology and general care of the ECLS patient have evolved, ECLS is not without potentially serious complications and remains unproven as a treatment modality. The therapy is now being tested in clinical trials, although numerous questions remain about the application of ECLS and its impact on outcomes in critically ill adults. PMID:25046529
Phase III Simplified Integrated Test (SIT) results - Space Station ECLSS testing
NASA Technical Reports Server (NTRS)
Roberts, Barry C.; Carrasquillo, Robyn L.; Dubiel, Melissa Y.; Ogle, Kathryn Y.; Perry, Jay L.; Whitley, Ken M.
1990-01-01
During 1989, phase III testing of Space Station Freedom Environmental Control and Life Support Systems (ECLSS) began at Marshall Space Flight Center (MSFC) with the Simplified Integrated Test. This test, conducted at the MSFC Core Module Integration Facility (CMIF), was the first time the four baseline air revitalization subsystems were integrated together. This paper details the results and lessons learned from the phase III SIT. Future plans for testing at the MSFC CMIF are also discussed.
International Space Station Environmental Control and Life Support System Status: 2006 - 2007
NASA Technical Reports Server (NTRS)
Williams, David E.; Gentry, Gregory J.
2007-01-01
The International Space Station (ISS) Environmental Control and Life Support (ECLS) system includes regenerative and non-regenerative technologies that provide the basic life support functions to support the crew, while maintaining a safe and habitable shirtsleeve environment. This paper provides a summary of the U.S. ECLS system activities over the past year, covering the period of time between March 2006 and February 2007. The ISS continued permanent crew operations, with the start of Phase 3 of the ISS Assembly Sequence. Work continued on the Phase 3 pressurized elements and the continued manufacturing and testing of the regenerative ECLS equipment.
International Space Station Environmental Control and Life Support System Status: 2008 - 2009
NASA Technical Reports Server (NTRS)
Williams, David E.; Gentry, Gregory J.; Gentry, Gregory J.
2009-01-01
The International Space Station (ISS) Environmental Control and Life Support (ECLS) system includes regenerative and non-regenerative technologies that provide the basic life support functions to support the crew, while maintaining a safe and habitable shirtsleeve environment. This paper provides a summary of the U.S. ECLS system activities over the past year, covering the period of time between March 2008 and February 2009. The ISS continued permanent crew operations, with the continuation of Phase 3 of the ISS Assembly Sequence. Work continues on the last of the Phase 3 pressurized elements and the continued manufacturing and testing of the regenerative ECLS equipment.
International Space Station Environmental Control and Life Support System Status: 2005 - 2006
NASA Technical Reports Server (NTRS)
Williams, David E.; Gentry, Gregory J.
2006-01-01
The International Space Station (ISS) Environmental Control and Life Support (ECLS) system includes regenerative and non-regenerative technologies that provide the basic life support functions to support the crew, while maintaining a safe and habitable shirtsleeve environment. This paper provides a summary of the U.S. ECLS system activities over the past year, covering the period of time between March 2005 and February 2006. The ISS continued permanent crew operations, with the start of Phase 3 of the ISS Assembly Sequence. Work continued on the Phase 3 pressurized elements and the continued manufacturing and testing of the regenerative ECLS equipment.
International Space Station (ISS) Environmental Control and Life Support System Status: 2003-2004
NASA Technical Reports Server (NTRS)
Williams, David E.; Gentry, Gregory
2004-01-01
The International Space Station (ISS) Environmental Control and Life Support (ECLS) system includes regenerative and non-regenerative technologies that provide the basic life support functions to support the crew, while maintaining a safe and habitable shirtsleeve environment. This paper provides a summary of the U.S. ECLS system activities over the past year, covering the period of time between April 2003 and March 2004. The ISS continued permanent crew operations, with the start of Phase 3 of the ISS Assembly Sequence. Work continued on the Phase 3 pressurized elements and the continued manufacturing and testing of the regenerative ECLS equipment.
2010-09-01
DEVELOPMENT TESTING BEING CONDUCTED AT THE REQUEST OF THE MSFC DYNAMICS, LOADS, AND STRENGTH BRANCH (EV31) TO STUDY THE FAILURE BEHAVIOR OF FASTENERS SUBJECTED TO COMBINED SHEAR AND TENSION LOADING. THE DATA FROM THIS TESTING WILL BE USED TO DEVELOP APPROPRIATE STRUCTURAL ANALYSIS METHODS AS PART OF A FASTENER STANDARDS EFFORT SPONSORED BY THE NASA ENGINEERING SAFETY CENTER (NESC). THE TEST FIXTURE WAS DESIGNED AND FABRICATED THROUGH THE MSFC MECHANICAL FABRICATION BRANCH (ES23). THE TESTING ORGANIZATION IS THE MSFC MATERIALS TEST BRANCH (EM10).
2010-09-01
DEVELOPMENT TESTING BEING CONDUCTED AT THE REQUEST OF THE MSFC DYNAMICS, LOADS, AND STRENGTH BRANCH (EV31) TO STUDY THE FAILURE BEHAVIOR OF FASTENERS SUBJECTED TO COMBINED SHEAR AND TENSION LOADING. THE DATA FROM THIS TESTING WILL BE USED TO DEVELOP APPROPRIATE STRUCTURAL ANALYSIS METHODS AS PART OF A FASTENER STANDARDS EFFORT SPONSORED BY THE NASA ENGINEERING SAFETY CENTER (NESC). THE TEST FIXTURE WAS DESIGNED AND FABRICATED THROUGH THE MSFC MECHANICAL FABRICATION BRANCH (ES23). THE TESTING ORGANIZATION IS THE MSFC MATERIALS TEST BRANCH (EM10).
2010-09-01
DEVELOPMENT TESTING BEING CONDUCTED AT THE REQUEST OF THE MSFC DYNAMICS, LOADS, AND STRENGTH BRANCH (EV31) TO STUDY THE FAILURE BEHAVIOR OF FASTENERS SUBJECTED TO COMBINED SHEAR AND TENSION LOADING. THE DATA FROM THIS TESTING WILL BE USED TO DEVELOP APPROPRIATE STRUCTURAL ANALYSIS METHODS AS PART OF A FASTENER STANDARDS EFFORT SPONSORED BY THE NASA ENGINEERING SAFETY CENTER (NESC). THE TEST FIXTURE WAS DESIGNED AND FABRICATED THROUGH THE MSFC MECHANICAL FABRICATION BRANCH (ES23). THE TESTING ORGANIZATION IS THE MSFC MATERIALS TEST BRANCH (EM10).
2010-09-01
DEVELOPMENT TESTING BEING CONDUCTED AT THE REQUEST OF THE MSFC DYNAMICS, LOADS, AND STRENGTH BRANCH (EV31) TO STUDY THE FAILURE BEHAVIOR OF FASTENERS SUBJECTED TO COMBINED SHEAR AND TENSION LOADING. THE DATA FROM THIS TESTING WILL BE USED TO DEVELOP APPROPRIATE STRUCTURAL ANALYSIS METHODS AS PART OF A FASTENER STANDARDS EFFORT SPONSORED BY THE NASA ENGINEERING SAFETY CENTER (NESC). THE TEST FIXTURE WAS DESIGNED AND FABRICATED THROUGH THE MSFC MECHANICAL FABRICATION BRANCH (ES23). THE TESTING ORGANIZATION IS THE MSFC MATERIALS TEST BRANCH (EM10).
Jardine, Griffin J; Holiman, Jeffrey D; Stoeger, Christopher G; Chamberlain, Winston D
2014-09-01
To improve accuracy and efficiency in quantifying the endothelial cell loss (ECL) in eye bank preparation of corneal endothelial grafts. Eight cadaveric corneas were subjected to Descemet Membrane Endothelial Keratoplasty (DMEK) preparation. The endothelial surfaces were stained with a viability stain, calcein AM dye (CAM) and then captured by a digital camera. The ECL rates were quantified in these images by three separate readers using trainable segmentation, a plug-in feature from the imaging software, Fiji. Images were also analyzed by Adobe Photoshop for comparison. Mean times required to process the images were measured between the two modalities. The mean ECL (with standard deviation) as analyzed by Fiji was 22.5% (6.5%) and Adobe was 18.7% (7.0%; p = 0.04). The mean time required to process the images through the two different imaging methods was 19.9 min (7.5) for Fiji and 23.4 min (12.9) for Adobe (p = 0.17). Establishing an accurate, efficient and reproducible means of quantifying ECL in graft preparation and surgical techniques can provide insight to the safety, long-term potential of the graft tissues as well as provide a quality control measure for eye banks and surgeons. Trainable segmentation in Fiji software using CAM is a novel approach to measuring ECL that captured a statistically significantly higher percentage of ECL comparable to Adobe and was more accurate in standardized testing. Interestingly, ECL as determined using both methods in eye bank-prepared DMEK grafts exceeded 18% on average.
Orbiter Enterprise at Marshall Space Flight Center for testing
2002-10-29
In this view, the Shuttle Orbiter Enterprise is seen heading South on Rideout Road with Marshall Space Flight Center's (MSFC'S) administrative 4200 Complex in the background, as it is being transported to MSFC's building 4755 for later Mated Vertical Ground Vibration tests (MVGVT) at MSFC's Dynamic Test Stand. The tests marked the first time ever that the entire shuttle complement (including Orbiter, external tank, and solid rocket boosters) were mated vertically.
Dual-peak electrogenerated chemiluminescence of carbon dots for iron ions detection.
Zhang, Pengjia; Xue, Zhenjie; Luo, Dan; Yu, Wei; Guo, Zhihui; Wang, Tie
2014-06-17
Carbon dots (CDs) have rigorously been investigated on their unique fluorescent properties but rarely their electrogenerated chemiluminescence (ECL) behavior. We are here to report a dual-peak ECL system of CDs, one at -2.84 V (ECL-1) and the other at -1.71 V (ECL-2) during the cyclic sweep between -3.0 and 3.0 V at scan rate of 0.2 V s(-1) in 0.1 M tetrabutyl ammonium bromide (TBAB) ethanol solution, which is more efficiency to distinguish metallic ions than single-peak ECL. The electron transfer reaction between individual electrochemically reduced nanocrystal species and coreactants led to ECL-1, in which the electron injected to the conduction band of CDs in the cathodic process. Ion annihilation reactions induced direct formation of exciplexes that produced another ECL signal, ECL-2. ECL-1 showed higher sensitivity to the surrounding environment than ECL-2 and thus was used for ECL detection of metallic ions. Herein, we can serve as an internal standard method to detect iron ions. A linear relationship of the intensity ratio R of ECL-1 and ECL-2 to iron ions was observed in the concentration extending from 5 × 10(-6) to 8 × 10(-5) M with a detection limit of 7 × 10(-7) M.
Haines, Nikkole; Wang, Shigang; Myers, John L; Undar, Akif
2009-11-01
We compared the effects of two neonatal extracorporeal life support (ECLS) systems on circuit pressures and surplus hemodynamic energy levels in a simulated ECLS model. The clinical set-up included the Jostra HL-20 heart-lung machine, either the Medtronic ECMO (0800) or the MEDOS 800LT systems with company-provided circuit components, a 10 Fr arterial cannula, and a pseudo-patient. We tested the system in nonpulsatile and pulsatile flow modes at two flow rates using a 40/60 glycerin/water blood analog, for a total of 48 trials, with n = 6 for each set-up. The pressure drops over the Medtronic ECLS were significantly higher than those over the MEDOS system regardless of the flow rate or perfusion mode (144.8 +/- 0.2 mm Hg vs. 35.7 +/- 0.2 mm Hg, respectively, at 500 mL/min in nonpulsatile mode, P < 0.001). The preoxygenator mean arterial pressures were significantly increased and the precannula hemodynamic energy values were decreased with the Medtronic ECLS circuit. These results suggest that the MEDOS ECLS circuit better transmits hemodynamic energy to the patient, keeps mean circuit pressures lower, and has lower pressure drops than the Medtronic Circuit.
Fleming, Geoffrey M; Remenapp, Robert T; Bartlett, Robert H; Annich, Gail M
2006-05-01
To assess the risk of hyperkalemia with blood-primed extracorporeal life support (ECLS) circuits in infants < 10 kg. Retrospective cohort study of all neonatal and pediatric patients < 10 kg placed on ECLS from May 1998 to April 2001. Data collection including patient weight, patient potassium levels pre- and post-initiation of ECLS, potassium level of the primed ECLS circuit, age of the packed red blood cell (PRBC) unit, type of preservative, and preservative reduction status. Seventy-six circuits were available for the analysis. The age of the PRBC unit and preservative reduction status significantly affected the potassium level of the primed ECLS circuit. Multivariate linear regression analysis showed no significant effect on the post-ECLS initiation patient potassium level with respect to the PRBC age, the preservative reduction status, the patient potassium level prior to ECLS initiation, and the potassium level of the primed ECLS circuit. Initiation of ECLS in infants < 10 kg should not be delayed unnecessarily to perform preservative reduction or to utilize PRBC units of a specific age, as hyperkalemia of the primed ECLS circuit is not associated with systemic hyperkalemia in the patient post-initiation of ECLS.
Cao, Yaling; Yuan, Ruo; Chai, Yaqin; Liu, Huijing; Liao, Yuhong; Zhuo, Ying
2013-09-15
An ultrasensitive electrochemiluminescence (ECL) immunosensor was constructed for ultrasensitive detection of carcinoembryonic antigen (CEA) based on an amplified cathodic ECL of luminol at low potential. Firstly, Au nanoparticles (AuNPs) were electrodeposited onto single walled carbon nanotube-graphene composites (CNTs-Gra) coated glass carbon electrode (GCE) with enhanced surface area and good biocompatibility to capture primary antibody (Ab1) and then bind the antigen analytes. Secondly, Pd and Pt nanoparticles (Pd&PtNPs) decorated reduced graphene oxide (Pd&PtNPs@rGO) and glucose oxidase (GOD) labeled secondary antibody (Pd&PtNPs@ rGO-GOD-Ab2) could be captured onto the electrode surface by a sandwich immunoassay protocol to generate amplified cathodic ECL signals of luminol in the presence of glucose. The Pd&PtNPs@rGO composites and loaded GOD promoted luminol cathodic ECL response by efficiently catalyzing glucose to in-situ produce amount of hydrogen peroxide (H2O2) working as a coreactant of luminol. Then in turn Pd&PtNPs catalyzed H2O2 to generate various reactive oxygen species (ROSs), which accelerated the cathodic ECL reaction of luminol, enhanced the cathodic ECL intensity of luminol and improved the sensitivity of the immunosensor. The as-proposed ECL immunosensor exhibited sensitive response on the detection of CEA ranging from 0.0001 ng mL(-1) to 160 ng mL(-1) with a detection limit of 0.03 pg mL(-1) (S/N=3). Moreover, the stability, specificity, lifetime and reproducibility tests demonstrated the feasibility of the developed immunoassay, which can be further extended to the detection of other disease biomarkers. Copyright © 2013 Elsevier B.V. All rights reserved.
Zhuo, Ying; Liao, Ni; Chai, Ya-Qin; Gui, Guo-Feng; Zhao, Min; Han, Jing; Xiang, Yun; Yuan, Ruo
2014-01-21
An alternative "signal on" immunosensor for ultrasensitive detection of apurinic/apyrimidinic endonuclease 1 (APE-1) was designed utilizing the self-enhanced electrochemiluminescence (ECL) of a novel Ru(II) complex functionalized coil-like nanocomposite as signal labels. The desirable self-enhanced ECL luminophore was achieved by combining the coreactant of poly(ethylenimine) (PEI) and the luminophor of bis(2,2'-bipyridine)-5-amino-1,10-phenanthroline ruthenium(II) [Ru(bpy)2(5-NH2-1,10-phen)(2+)] to form one novel Ru(II) complex, which exhibited significantly enhanced ECL efficiency and stability. Moreover, the carbon nanotubes (CNTs) were employed as nanocarriers for self-enhanced Ru(II) complex loading via π-π stacking to obtain the coil-like nanocomposite to act as signal probe. Compared with traditional ECL immunoassay, our proposed strategy is simple and sensitive, avoiding the adding of any coreactant into testing solution for signal amplification, and shows a detection limit down to subfemtogram per milliliter level under the optimized experimental condition.
Parekh, Mohit; Ruzza, Alessandro; Romano, Vito; Favaro, Elisa; Baruzzo, Mattia; Salvalaio, Gianni; Grassetto, Andrea; Ferrari, Stefano; Ponzin, Diego
2018-06-01
To investigate the learning curve of Descemet membrane endothelial keratoplasty (DMEK) graft preparation in an eye bank. Four operators prepared 645 DMEK grafts using the stripping technique between 2014 and 2017 at the Veneto Eye Bank Foundation, Italy. Endothelial cell loss (ECL) and tissue wastage were recorded retrospectively after DMEK preparation and correlated with the number of tissues prepared each year by each operator. On average, our operators performed 1 donor preparation a week over the course of this study. Only donors older than 60 years were used in this study, and approximately 10% of donors had diabetes. The Wilcoxon test for paired data and 1-way ANOVA were used for checking statistical significance with the Tukey test as post hoc analysis. P < 0.05 was considered statistically significant. ECL did not change significantly over time from operator 1. Significant ECL drop was noted from operator 2 between years 2014-2016 (P = 0.0049) and 2017 (P = 0.0094); from operator 3 between years 2015-2016 (P = 0.0288) and 2017 (P = 0.0097); and from operator 4 between 2015-2016 (P = 0.0469) and 2017 (P = 0.0331). Operators 1 and 3 did not show a significant difference, considering every 50 grafts prepared by each operator. Operator 2 showed significant ECL drop between 1 to 50 and 51 to 100 (P = 0.0002) and 1 to 50 and 101 to 150 (P = 0.0001) grafts. Operator 4 showed significant ECL drop between 1 to 50 and 101 to 150 (P = 0.002) and 51 to 100 and 101 to 141 (P = 0.0207) grafts. No intraoperator difference was observed per 50 grafts (P > 0.05). There is a learning curve for DMEK graft preparation. ECL and tissue wastage can be reduced with practice and skills. However, each operator may be limited to his or her own learning capability.
Design and Application of Multi-functional Electrogenerated Chemiluminescence Imaging Analyzer.
Jiang, Guangfu; Liu, Xia; Wang, Yaqin; Ruan, Sanpeng; Qi, Honglan; Yang, Yong; Zhou, Qishe; Zhang, Chengxiao
2016-01-01
A multi-functional eletrogenerated chemiluminescence (ECL) imaging analyzer including both a photomultiplier tube and charged coupled device as detectors has been developed. The ECL imaging analyzer can effectively work for electrochemical study, ECL intensity detection at electrode array, and ECL imaging at bipolar electrodes or electrode array. As an ECL imaging example, an ECL biosensor for visual detection of matrix metalloproteinase 7 in the range from 0.05 to 1 ng/mL is demonstrated.
AXAF-1 High Resolution Assembly Image Model and Comparison with X-Ray Ground Test Image
NASA Technical Reports Server (NTRS)
Zissa, David E.
1999-01-01
The x-ray ground test of the AXAF-I High Resolution Mirror Assembly was completed in 1997 at the X-ray Calibration Facility at Marshall Space Flight Center. Mirror surface measurements by HDOS, alignment results from Kodak, and predicted gravity distortion in the horizontal test configuration are being used to model the x-ray test image. The Marshall Space Flight Center (MSFC) image modeling serves as a cross check with Smithsonian Astrophysical observatory modeling. The MSFC image prediction software has evolved from the MSFC model of the x-ray test of the largest AXAF-I mirror pair in 1991. The MSFC image modeling software development is being assisted by the University of Alabama in Huntsville. The modeling process, modeling software, and image prediction will be discussed. The image prediction will be compared with the x-ray test results.
Won, Jonghun; Lee, Gyu Rie; Park, Hahnbeom; Seok, Chaok
2018-06-07
The second extracellular loops (ECL2s) of G-protein-coupled receptors (GPCRs) are often involved in GPCR functions, and their structures have important implications in drug discovery. However, structure prediction of ECL2 is difficult because of its long length and the structural diversity among different GPCRs. In this study, a new ECL2 conformational sampling method involving both template-based and ab initio sampling was developed. Inspired by the observation of similar ECL2 structures of closely related GPCRs, a template-based sampling method employing loop structure templates selected from the structure database was developed. A new metric for evaluating similarity of the target loop to templates was introduced for template selection. An ab initio loop sampling method was also developed to treat cases without highly similar templates. The ab initio method is based on the previously developed fragment assembly and loop closure method. A new sampling component that takes advantage of secondary structure prediction was added. In addition, a conserved disulfide bridge restraining ECL2 conformation was predicted and analytically incorporated into sampling, reducing the effective dimension of the conformational search space. The sampling method was combined with an existing energy function for comparison with previously reported loop structure prediction methods, and the benchmark test demonstrated outstanding performance.
1965-01-01
Marshall Space Flight Center (MSFC) workers lower S-IB-200D, a dynamic test version of the Saturn IB launch vehicle's first stage (S-IB stage), into the Center's Dynamic Test Stand on January 12, 1965. Test Laboratory persornel assembled a complete Saturn IB to test the structural soundness of the launch vehicle. Developed by the MSFC as an interim vehicle in MSFC's "building block" approach to Saturn rocket development, the Saturn IB utilized Saturn I technology to further develop and refine large boosters and the Apollo spacecraft capabilities required for the manned lunar missions.
1965-01-01
S-IB-200D, a dynamic test version of the Saturn IB launch vehicle's first stage (S-IB), makes its way to the Marshall Space Flight Center (MSFC) East Test Area on January 4, 1965. Test Laboratory persornel assembled a complete Saturn IB to test the structural soundness of the launch vehicle in the Dynamic Test Stand. Developed by the MSFC as an interim vehicle in MSFC's "building block" approach to the Saturn rocket development, the Saturn IB utilized Saturn I technology to further develop and refine the larger boosters and the Apollo spacecraft capabilities required for the manned lunar missions.
ASM Student Technology and Career Night
NASA Technical Reports Server (NTRS)
Hamilton, Jeff
2005-01-01
This viewgraph presentation presents a general overview of Marshall Space Flight Center (MSFC) for students who are perspective MSFC employees. The presentation includes an organizational chart and a summary of MSFC activities, as well as photographs and descriptions of some of the center's test facilities.
Senator Doug Jones (D-AL) Tour of MSFC Facilities
2018-02-22
Senator Doug Jones (D-AL.) and wife, Louise, tour Marshall Space Flight facilities. Steve Doering, manager, Stages Element, Space Launch System (SLS) program at MSFC, along with Senator and Mrs. Jones, viewed the MSFC campus from the top of test stand 4693.
2014-01-01
Background There is no available data on clinical outcome in patients with acute myocardial infarction (AMI) complicated by cardiogenic shock who are supported by an intra-aortic balloon pump (IABP) in combination with extracorporeal life support (ECLS). Methods We analysed 96 consecutive patients with AMI and complicating cardiogenic shock who were assisted by an ECLS system between January 2004 and December 2011. The primary outcome was in-hospital mortality. The secondary outcomes were the success rate of weaning from ECLS and the lactate clearance for 48 hours (%). Results A combination of IABP and ECLS was used in 41 (42.7%) patients. In-hospital mortality occurred for 51 patients (ECLS with IABP versus ECLS alone; 51.2% vs. 54.5%, p = 0.747). The success rate of weaning from ECLS was similar between the two groups (63.4% vs. 58.2%, p = 0.604). Complications such as ischemia of a lower extremity or bleeding at the ECLS insertion site (p = 0.521 and p = 0.667, respectively) did not increase when ECLS was combined with IABP. Among patients who survived for 24 hours after intervention, lactate clearance was not significantly different between patients who received ECLS alone and those who received ECLS with IABP (p = 0.918). Conclusions The combined use of ECLS and IABP did not improve in-hospital survival in patients with AMI complicated by cardiogenic shock. PMID:24725532
NASA Technical Reports Server (NTRS)
Kenny, R. J.; Greene, W. D.
2016-01-01
This presentation covers the overall scope, schedule, and activities associated with the NASA - Marshall Space Flight Center (MSFC) involvement with the Combustion Stability Tool Development (CSTD) program. The CSTD program is funded by the Air Force Space & Missile Systems Center; it is approximately two years in duration and; and it is sponsoring MSFC to: design, fabricate, & execute multi-element hardware testing, support Air Force Research Laboratory (AFRL) single element testing, and execute testing of a small-scale, multi-element combustion chamber. Specific MSFC Engineering Directorate involvement, per CSTD-sponsored task, will be outlined. This presentation serves a primer for the corresponding works that provide details of the technical work performed by individual groups within MSFC.
Zhang, Han; Zuo, Fumei; Tan, Xingrong; Xu, Shenghao; Yuan, Ruo; Chen, Shihong
2018-05-01
An electrochemiluminescencent (ECL) biosensor was designed for the determination of insulin using a novel ECL resonance energy transfer (ECL-RET) strategy. In this strategy, carboxyl poly(9,9-dioctyfluorenyl-2,7-diyl) dots (PFO dots) were worked as ECL donor and 3,4,9,10-perylenetetracar-boxylic acid (PTCA) exploited as ECL acceptor, and hydrogen peroxide (H 2 O 2 ) employed as the coreactant. The ECL donor and ECL acceptor were separately labeled with primary antibody (Ab 1 ) and secondary antibody (Ab 2 ), forming a sensing interface to the analyte target, insulin. In this expected sandwich-type ECL biosensor, PFO dots acted as sensing platform and PTCA employed as labels to quench the ECL emission of PFO dots. During the determination process, ECL signal of PFO dots was decreased in a gradual way by the increase of insulin concentration, and the quenching mechanism was also investigated. Under the optimal experimental conditions, the constructed biosensor exhibited an excellent performance, including a wide linear range from 1.0 × 10 -5 ng/mL to 1.0 × 10 2 ng/mL, low detection limit of 3.0 × 10 -6 ng/mL, good stability and selectivity for the detection of insulin. This pair of PFO-PTCA, as a new donor-acceptor pair in ECL-RET system, would provide a promising platform for bioanalysis in ECL field. Copyright © 2017 Elsevier B.V. All rights reserved.
Zhu, Wenjuan; Wang, Chao; Li, Xiaojian; Khan, Malik Saddam; Sun, Xu; Ma, Hongmin; Fan, Dawei; Wei, Qin
2017-11-15
Novel and sensitive sandwich-type electrochemiluminescence (ECL) immunosensor was fabricated for insulin detection. Au-ZnCd 14 S combined nitrogen doping mesoporous carbons (Au-ZnCd 14 S/NH 2 -NMCs) acted as sensing platform and Au-Cu alloy nanocrystals were employed as labels to quench the ECL of Au-ZnCd 14 S/NH 2 -NMCs. Zinc-doping promoted the ECL behavior of CdS nanocrystals, with the best ECL emission obtained when the molar ratio of Zn/Cd was 1:14. Simultaneously, the modification of gold nanoparticles (Au NPs) and combination with NH 2 -NMC further enhanced the ECL emission of ZnCd 14 S due to its excellent conductivity and large specific surface area, which is desirable for the immunosensor construction. Au-Cu alloy nanocrystals were employed in the ECL system of ZnCd 14 S/K 2 S 2 O 8 triggering ECL quenching effects. The ECL spectra of ZnCd 14 S, acting as the energy donor, exhibited well overlaps with the absorption band of Au-Cu alloy nanocrystals which acted as the energy acceptor, leading to an effective ECL resonance energy transfer (ECL-RET). On the basis of the ECL quenching effects, a sensitive ECL immunosensor for insulin detection was successfully constructed with a linear response range of insulin concentration from 0.1pg/mL to 30ng/mL and the limit of detection was calculated to be 0.03pg/mL (S/N = 3). Copyright © 2017 Elsevier B.V. All rights reserved.
Summary of LOX/CH4 Thruster Technology Development at NASA/MSFC
NASA Technical Reports Server (NTRS)
Greene, Sandra Elam
2015-01-01
In recent years, a variety of injectors for liquid oxygen (LOX) and methane (CH4) propellant systems have been designed, fabricated, and demonstrated with hot-fire testing at Marshall Space Flight Center (MSFC). Successful designs for liquid methane (LCH4) and gaseous methane (GCH4) have been developed. A variety of chambers, including a transpiration cooled design, along with uncooled ablatives and refractory metals, have also been hot-fire tested by MSFC for use with LOX/LCH4 injectors. Hot-fire testing has also demonstrated multiple ignition source options. Heat flux data for selected injectors has been gathered by testing with a calorimeter chamber. High performance and stable combustion have been demonstrated, along with designs for thrust levels ranging from 500 to 7,000 lbf. The newest LOX/CH4 injector and chamber developed by MSFC have been fabricated with additive manufacturing techniques and include unique design features to investigate regenerative cooling with methane. This low cost and versatile hardware offers a design for 4,000 lbf thrust and will be hot-fire tested at MSFC in 2015. Its design and operation can easily be scaled for use in systems with thrust levels up to 25,000 lbf.
1990-08-29
Multiple lightning bolts struck the Technology Test Bed, formerly the S-IC Static Test Stand, at the Marshall Space Flight Center (MSFC) during a thunderstorm. This spectacular image of lightning was photographed by MSFC photographer Dernis Olive on August 29, 1990.
CDRA-4EU Testing in Support of ISS
NASA Technical Reports Server (NTRS)
Peters, Warren; Stanley, Christine; Knox, Jim
2016-01-01
NASA's Marshall Space Flight Center (MSFC) recently conducted tests on two desiccant beds of the four-bed molecular sieve carbon dioxide removal assembly (CDRA) returned from the International Space Station (ISS). MSFC had previously characterized the relationship between CDRA-4EU inlet conditions and the dewpoint at the desiccant bed exit and between the compressor and accumulator that make up the Carbon Dioxide Management Assembly (CDMA). MSFC installed the flight desiccant beds into the existing Exploration Test Chamber (E-chamber) using a suite of instrumentation not available on orbit to investigate the orbital performance of the desiccant beds. Test objectives, facility design and test results are presented.
Liang, Wenbin; Zhuo, Ying; Xiong, Chengyi; Zheng, Yingning; Chai, Yaqin; Yuan, Ruo
2017-08-15
A sensitive electrochemiluminescent (ECL) sandwich immunosensor was proposed herein based on the tris (2-phenylpyridine) iridium [Ir(ppy) 3 ] doped silica nanoparticles (SiO 2 @Ir) with improved ECL emission as signal probes and glucose oxidase (GOD)-based in situ enzymatic reaction to generate H 2 O 2 for efficiently quenching the ECL emission of SiO 2 @Ir. Typically, the SiO 2 @Ir not only increased the loading amount of Ir(ppy) 3 as ECL indicators with high ECL emission, but also improved their water-solubility, which efficiently enhanced the ECL emission. Furthermore, by the efficient quench effect of H 2 O 2 from in situ glucose oxidase (GOD)-based enzymatic reaction on the ECL emission of SiO 2 @Ir, a signal-off ECL immunsensor could be established for sensitive assay. With N-terminal of the prohormone brain natriuretic peptide (BNPT) as a model, the proposed ECL assay performed high sensitivity and low detection limit. Importantly, the proposed sensitive ECL strategy was not only suitable for the detection of BNPT for acute myocardial infarction, but also revealed a new avenue for early diagnosis of various diseases via proteins, nucleotide sequence, microRNA and cells. Copyright © 2017 Elsevier B.V. All rights reserved.
NEARING THE END OF CONSTRUCTION ON THE LOX TEST STAND AT MSFC.
2015-01-08
AS THE END OF CONSTRUCTION ON TEST STAND 4697, THE LIQUID OXYGEN TANK TEST STAND AT MARSHALL SPACE FLIGHT CENTER, PROJECT ENGINEERS PHIL HENDRIX, FROM MSFC, AND CURTNEY WALTERS FROM THE U.S. CORP OF ENGINEERS, STUDY PLANS AND PROGRESS.
Huang, Yin; Lei, Jianping; Cheng, Yan; Ju, Huangxian
2016-03-15
This work designed a novel ratiometric electrochemiluminescence (ECL) immunosensing approach based on two different ECL emitters: CdS quantum dots (QDs) as cathodic emitter and luminol as anodic emitter. The ECL immunosensor was constructed by a layer-by-layer modification of CdS QDs, Au nanoparticles and capture antibody on a glassy carbon electrode. With hydrogen peroxide as ECL coreactant, the immunosensor showed a cathodic ECL emission of CdS QDs at -1.5 V (vs Ag/AgCl) in air-saturated pH 8.0 buffer. Upon the formation of sandwich immunoassay, the lumiol/palladium nanoclusters (Pd NCs)@graphene oxide probe was introduced to the electrode. Therefore, the cathodic ECL intensity decreased and luminol anodic ECL emission was appeared at +0.3 V (vs Ag/AgCl) owing to the competition of the coreactant of hydrogen peroxide. Using carcino-embryonic antigen as model, this ratiometric ECL strategy could be used for immunoassay with a linear range of 1.0-100 pg mL(-1) and a detection limit of 0.62 pg mL(-1). The enhanced ratiometric ECL signal resulted from the high density and excellent electrocatalysis of the loaded Pd NCs. The immunosensor exhibited good stability and acceptable fabrication reproducibility and accuracy, showing a great promising for clinical application. This electrocatalysis-regulated ratiometric ECL provides a new concept for ECL measurement, and could be conveniently extended for detection of other protein biomarkers. Copyright © 2015 Elsevier B.V. All rights reserved.
Miao, Dongmei; Steck, Andrea K.; Zhang, Li; Guyer, K. Michelle; Jiang, Ling; Armstrong, Taylor; Muller, Sarah M.; Krischer, Jeffrey; Rewers, Marian
2015-01-01
Abstract We recently developed new electrochemiluminescence (ECL) insulin autoantibody (IAA) and glutamic acid decarboxylase 65 autoantibody (GADA) assays that discriminate high-affinity, high-risk diabetes-specific autoantibodies from low-affinity, low-risk islet autoantibodies (iAbs) detected by radioassay (RAD). Here, we report a further validation of the ECL-IAA and -GADA assays in 3,484 TrialNet study participants. The ECL assay and RAD were congruent in those with prediabetes and in subjects with multiple autoantibodies, but only 24% (P<0.0001) of single RAD-IAA-positive and 46% (P<0.0001) of single RAD-GADA-positive were confirmed by the ECL-IAA and -GADA assays, respectively. During a follow-up (mean, 2.4 years), 51% of RAD-IAA-positive and 63% of RAD-GADA-positive subjects not confirmed by ECL became iAb negative, compared with only 17% of RAD-IAA-positive (P<0.0001) and 15% of RAD-GADA-positive (P<0.0001) subjects confirmed by ECL assays. Among subjects with multiple iAbs, diabetes-free survival was significantly shorter if IAA or GADA was positive by ECL and negative by RAD than if IAA or GADA was negative by ECL and positive by RAD (P<0.019 and P<0.0001, respectively). Both positive and negative predictive values in terms of progression to type 1 diabetes mellitus were superior for ECL-IAA and ECL-GADA, compared with RADs. The prevalence of the high-risk human leukocyte antigen-DR3/4, DQB1*0302 genotype was significantly higher in subjects with RAD-IAA or RAD-GADA confirmed by ECL. In conclusion, both ECL-IAA and -GADA are more disease-specific and better able to predict the risk of progression to type 1 diabetes mellitus than the current standard RADs. PMID:25562486
Miao, Dongmei; Steck, Andrea K; Zhang, Li; Guyer, K Michelle; Jiang, Ling; Armstrong, Taylor; Muller, Sarah M; Krischer, Jeffrey; Rewers, Marian; Yu, Liping
2015-02-01
We recently developed new electrochemiluminescence (ECL) insulin autoantibody (IAA) and glutamic acid decarboxylase 65 autoantibody (GADA) assays that discriminate high-affinity, high-risk diabetes-specific autoantibodies from low-affinity, low-risk islet autoantibodies (iAbs) detected by radioassay (RAD). Here, we report a further validation of the ECL-IAA and -GADA assays in 3,484 TrialNet study participants. The ECL assay and RAD were congruent in those with prediabetes and in subjects with multiple autoantibodies, but only 24% (P<0.0001) of single RAD-IAA-positive and 46% (P<0.0001) of single RAD-GADA-positive were confirmed by the ECL-IAA and -GADA assays, respectively. During a follow-up (mean, 2.4 years), 51% of RAD-IAA-positive and 63% of RAD-GADA-positive subjects not confirmed by ECL became iAb negative, compared with only 17% of RAD-IAA-positive (P<0.0001) and 15% of RAD-GADA-positive (P<0.0001) subjects confirmed by ECL assays. Among subjects with multiple iAbs, diabetes-free survival was significantly shorter if IAA or GADA was positive by ECL and negative by RAD than if IAA or GADA was negative by ECL and positive by RAD (P<0.019 and P<0.0001, respectively). Both positive and negative predictive values in terms of progression to type 1 diabetes mellitus were superior for ECL-IAA and ECL-GADA, compared with RADs. The prevalence of the high-risk human leukocyte antigen-DR3/4, DQB1*0302 genotype was significantly higher in subjects with RAD-IAA or RAD-GADA confirmed by ECL. In conclusion, both ECL-IAA and -GADA are more disease-specific and better able to predict the risk of progression to type 1 diabetes mellitus than the current standard RADs.
Pediatric Extracorporeal Life Support Organization Registry International Report 2016.
Barbaro, Ryan P; Paden, Matthew L; Guner, Yigit S; Raman, Lakshmi; Ryerson, Lindsay M; Alexander, Peta; Nasr, Viviane G; Bembea, Melania M; Rycus, Peter T; Thiagarajan, Ravi R
The purpose of this report is to describe the international growth, outcomes, complications, and technology used in pediatric extracorporeal life support (ECLS) from 2009 to 2015 as reported by participating centers in the Extracorporeal Life Support Organization (ELSO). To date, there are 59,969 children who have received ECLS in the ELSO Registry; among those, 21,907 received ECLS since 2009 with an overall survival to hospital discharge rate of 61%. In 2009, 2,409 ECLS cases were performed at 157 centers. By 2015, that number grew to 2,992 cases in 227 centers, reflecting a 24% increase in patients and 55% growth in centers. ECLS delivered to neonates (0-28 days) for respiratory support was the largest subcategory of ECLS among children <18-years old. Overall, 48% of ECLS was delivered for respiratory support and 52% was for cardiac support or extracorporeal life support to support cardiopulmonary resuscitation (ECPR). During the study period, over half of children were supported on ECLS with centrifugal pumps (51%) and polymethylpentene oxygenators (52%). Adverse events including neurologic events were common during ECLS, a fact that underscores the opportunity and need to promote quality improvement work.
A review of electrochemiluminescence (ECL) in and for microfluidic analytical devices.
Kirschbaum, Stefanie E K; Baeumner, Antje J
2015-05-01
The concept and realization of microfluidic total analysis systems (microTAS) have revolutionized the analytical process by integrating the whole breadth of analytical techniques into miniaturized systems. Paramount for efficient and competitive microTAS are integrated detection strategies, which lead to low limits of detection while reducing the sample volume. The concept of electrochemiluminescence (ECL) has been intriguing ever since its introduction based on Ru(bpy)3 (2+) by Tokel and Bard [1] (J Am Chem Soc 1853:2862-2863, 1972), especially because of its immense sensitivity, nonexistent auto-luminescent background signal, and simplicity in experimental design. Therefore, integrating ECL detection into microTAS is a logical consequence to achieve simple, yet highly sensitive, sensors. However, published microanalytical devices employing ECL detection focus in general on traditional ECL chemistry and have yet to take advantage of advances made in standard bench-top ECL strategies. This review will therefore focus on the most recent advancements in microfluidic ECL approaches, but also evaluate the potential impact of bench-top ECL research progress that would further improve performance and lower limits of detection of micro analytical ECL systems, ensuring their desirability as detection principle for microTAS applications.
Electrochemistry and electrochemiluminescence from a redox-active metal-organic framework.
Xu, Yang; Yin, Xue-Bo; He, Xi-Wen; Zhang, Yu-Kui
2015-06-15
The marriage of metal-organic frameworks (MOFs) and electrochemiluminescence (ECL) can combine their merits together. Designing ECL-active MOF with a high electron transfer capacity and high stability is critical for ECL emission. Here we reported the ECL from a redox-active MOF prepared from {Ru[4,4'-(HO2C)2-bpy]2bpy}(2+) and Zn(2+); a property of MOFs has not been reported previously. The MOF structure is independent of its charge and is therefore stable electrochemically. The redox-activity and well-ordered porous structure of the MOF were confirmed by its electrochemical properties and ECL emission. The high ECL emission indicated the ease of electron transfer between the MOF and co-reactants. Furthermore, the MOF exhibited permselectivity, charge selectivity, and catalytic selectivity along with a stable and concentration-dependent ECL emission toward co-reactants. ECL mechanism was proposed based on the results. The detection and recovery of cocaine in the serum sample was used to validate the feasibility of MOF- based ECL system. The information obtained in this study provides a better understanding of the redox properties of MOFs and their potential electrochemical applications. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Williams, David E.; Spector, Lawrence N.
2009-01-01
Node 1 (Unity) flew to International Space Station (ISS) on Flight 2A. Node 1 was the first module of the United States On-Orbit Segment (USOS) launched to ISS. The Node 1 ISS Environmental Control and Life Support (ECLS) design featured limited ECLS capability. The main purpose of Node 1 was to provide internal storage by providing four stowage rack locations within the module and to allow docking of multiple modules and a truss segment to it. The ECLS subsystems inside Node 1 were routed through the element prior to launch to allow for easy integration of the attached future elements, particularly the Habitation Module which was planned to be located at the nadir docking port of Node 1. After Node 1 was on-orbit, the Program decided not to launch the Habitation Module and instead, to replace it with Node 3 (Tranquility). In 2007, the Program became concerned with a potential Russian docking port approach issue for the Russian FGB nadir docking port after Node 3 is attached to Node 1. To solve this concern the Program decided to relocate Node 3 from Node 1 nadir to Node 1 port. To support the movement of Node 3 the Program decided to build a modification kit for Node 1, an on-orbit feedthrough leak test device, and new vestibule jumpers to support the ECLS part of the relocation. This paper provides a design overview of the modification kit, a summary of the Node 1 ECLS re-verification to support the Node 3 relocation from Node 1 nadir to Node 1 port, and a status of the ECLS modification kit installation into Node 1.
NASA Technical Reports Server (NTRS)
Williams, David E.; Spector Lawrence N.
2010-01-01
Node 1 (Unity) flew to International Space Station (ISS) on Flight 2A. Node 1 was the first module of the United States On-Orbit Segment (USOS) launched to ISS. The Node 1 ISS Environmental Control and Life Support (ECLS) design featured limited ECLS capability. The main purpose of Node 1 was to provide internal storage by providing four stowage rack locations within the module and to allow docking of multiple modules and a truss segment to it. The ECLS subsystems inside Node 1 were routed through the element prior to launch to allow for easy integration of the attached future elements, particularly the Habitation Module which was planned to be located at the nadir docking port of Node 1. After Node I was on-orbit, the Program decided not to launch the Habitation Module and instead, to replace it with Node 3 (Tranquility). In 2007, the Program became concerned with a potential Russian docking port approach issue for the Russian FGB nadir docking port after Node 3 is attached to Node 1. To solve this concern the Program decided to relocate Node 3 from Node I nadir to Node 1 port. To support the movement of Node 3 the Program decided to build a modification kit for Node 1, an on-orbit feedthrough leak test device, and new vestibule jumpers to support the ECLS part of the relocation. This paper provides a design overview of the modification kit for Node 1, a summary of the Node 1 ECLS re-verification to support the Node 3 relocation from Node 1 nadir to Node 1 port, and a status of the ECLS modification kit installation into Node 1.
Biočina, Bojan; Petričević, Mate; Belina, Dražen; Gašparović, Hrvoje; Svetina, Lucija; Konosić, Sanja; White, Alexandra; Ivančan, Višnja; Kopjar, Tomislav; Miličić, Davor
2014-01-01
Aim To describe our experience in the clinical application of extracorporeal life support (ECLS) and analyze whether ECLS leads to acceptable clinical outcomes in patients with cardiac failure. Methods Data from clinical database of University Hospital Center Zagreb, Croatia, on 75 patients undergoing ECLS support from 2009 to 2014 due to cardiac failure were retrospectively analyzed. Outcomes were defined as procedural and clinical outcomes. ECLS as a primary procedure and ECLS as a postcardiotomy procedure due to inability to wean from cardiopulmonary bypass were analyzed. Results ECLS was used in 75 adult patients, and in 24 (32%) of those procedural success was noted. ECLS was implemented as a primary procedure in 36 patients and as a postcardiotomy procedure in 39 patients. Nine out of 39 (23.08%) patients had postcardiotomy ECLS after heart transplantation. Bleeding complications occurred in 30 (40%) patients, both in primary (11/36 patients) and postcardiotomy group (19/39 patients). ECLS was established by peripheral approach in 46 patients and by central cannulation in 27 patients. In 2 patients, combined cannulation was performed, with an inflow cannula placed into the right atrium and an outflow cannula placed into the femoral artery. Eleven patients treated with peripheral approach had ischemic complications. Conclusion ECLS is a useful tool in the treatment of patients with refractory cardiac failure and its results are encouraging in patients who otherwise have an unfavorable prognosis. PMID:25559831
6. PRELIMINARY SKETCH FOR A NEW REDSTONE ARSENAL HEADQUARTERS AND ...
6. PRELIMINARY SKETCH FOR A NEW REDSTONE ARSENAL HEADQUARTERS AND ENGINEERING AREA. (PRESENT DAY MARSHALL SPACE FLIGHT CENTER), INCLUDING TEST AREA NUMBER 2 (MSFC, EAST TEST AREA). SEPTEMBER 1951, HANNES LUEHRSEN COLLECTION, MSFC MASTER PLANNING OFFICE. - Marshall Space Flight Center, East Test Area, Dodd Road, Huntsville, Madison County, AL
Low-Energy Microfocus X-Ray Source for Enhanced Testing Capability in the Stray Light Facility
NASA Technical Reports Server (NTRS)
Gaskin, Jessica; O'Dell, Stephen; Kolodziejczak, Jeff
2015-01-01
Research toward high-resolution, soft x-ray optics (mirrors and gratings) necessary for the next generation large x-ray observatories requires x-ray testing using a low-energy x-ray source with fine angular size (<1 arcsecond). To accommodate this somewhat demanding requirement, NASA Marshall Space Flight Center (MSFC) has procured a custom, windowless low-energy microfocus (approximately 0.1 mm spot) x-ray source from TruFocus Corporation that mates directly to the Stray Light Facility (SLF). MSFC X-ray Astronomy team members are internationally recognized for their expertise in the development, fabrication, and testing of grazing-incidence optics for x-ray telescopes. One of the key MSFC facilities for testing novel x-ray instrumentation is the SLF. This facility is an approximately 100-m-long beam line equipped with multiple x-ray sources and detectors. This new source adds to the already robust compliment of instrumentation, allowing MSFC to support additional internal and community x-ray testing needs.
Freundt, Miriam; Lunz, Dirk; Philipp, Alois; Panholzer, Bernd; Lubnow, Matthias; Friedrich, Christine; Rupprecht, Leopold; Hirt, Stephan; Haneya, Assad
2017-01-01
Veno-arterial extracorporeal life support (ECLS) is an established method to stabilize acute circulatory failure. Parameters and data on when to ideally wean circulatory support are limited. Bilirubin is a marker of end-organ damage. Therefore, the purpose of this large study was to evaluate the impact of dynamic changes of elevated bilirubin levels on survival in patients on ECLS. We reviewed 502 consecutive cases of ECLS from 2007 to 2015. Bilirubin levels were recorded before implantation and until six days after explantation. Dynamic bilirubin changes, and hemodynamic and laboratory outcome parameters were compared in survivors and nonsurvivors. Reason for ECLS implantation was cardiac arrest with ongoing resuscitation in 230 (45.8%), low cardiac output in 174 (34.7%) and inability to wean off cardiopulmonary bypass in 98 (19.5%) patients. 307 (61.2%) patients were weaned off ECLS, however, 206 (41.0%) survived. Mean duration of ECLS was 3 (2-6) days, and survivors received significantly longer ECLS (5 vs 3 days, p < 0.001). Survivors had significantly lower baseline bilirubin levels (p = 0.003). Bilirubin started to rise from day 2 in all patients. In survivors, bilirubin levels had trended down on the day of ECLS explantation and stayed at an acceptable level. However, in weaned patients who did not survive and patients who died on ECLS bilirubin levels continued to rise during the recorded period. ECLS support improves survival in patients with acute circulatory failure. Down trending bilirubin levels on veno-arterial ECLS indicate improved chances of successful weaning and survival in hemodynamically stable patients.
NASA/MSFC's Calculation for Test Case 1a of ATAC-FSDC Workshop on After-body and Nozzle Flows
NASA Technical Reports Server (NTRS)
Ruf, Joseph H.
2006-01-01
Mr. Ruf of NASA/MSFC executed the CHEM computational fluid dynamics (CFD) code to provide a prediction of the test case 1 a for the ATAC-FSDC Workshop on After-body and Nozzle Flows. CHEM is used extensively at MSFC for a wide variety of fluid dynamic problems. These problems include; injector element flows, nozzle flows, feed line flows, turbomachinery flows, solid rocket motor internal flows, plume vehicle flow interactions, etc.
NASA Astrophysics Data System (ADS)
Moon, Hong Chul; Lodge, Timothy P.; Frisbie, C. Daniel
2014-03-01
We have expanded the functionality of ion gels and successfully demonstrated low voltage, flexible electrochemiluminescent (ECL) devices using patterned ECL gels. An ECL device composed of only an emissive gel and two electrodes was fabricated on an ITO-coated substrate by solution casting the ECL gel and brush-painting the top silver electrode. The device turned on at an AC voltage as low as 2.6 V (-1.3 V ~ +1.3 V) and showed a relatively rapid response (sub-ms). Also, we varied the mechanical properties of the ECL gel simply by substituting polystyrene-block-poly(methyl methacrylate)-block-polystyrene (SMS) with commercially available poly(vinylidene fluoride-co-hexafluoropropylene) (P(VDF-co-HFP)), enabling the fabrication of flexible ECL devices on any target substrate by the ``cut-and-stick'' strategy. This simple, rubbery ECL gel should be attractive for flexible electronics applications such as displays on packaging.
Yan, Yuting; Liu, Qian; Wang, Kun; Jiang, Ling; Yang, Xingwang; Qian, Jing; Dong, Xiaoya; Qiu, Baijing
2013-12-07
This work reports a novel strategy to amplify the electrochemiluminescence (ECL) signal of peroxydisulfate solution based on the Au nanoparticle decorated reduced graphene oxide (Au NP-RGO), and further an ECL biosensor for sensitive and selective detection of dopamine (DA) was constructed. Due to the synergistic amplification of Au NPs and RGO, the ECL signal of peroxydisulfate solution on the Au NP-RGO modified electrode was about 5-fold enhanced compared to that of the bare electrode with the ECL onset potential positively shifted from -1.2 V to -0.9 V. More interestingly, the ECL intensity of peroxydisulfate solution increased with the increase of DA concentration, based on which an ECL biosensor for DA determination was fabricated. The as-prepared solid-state ECL DA sensor showed a wide linear response of 0.02-40 μM with a detection limit of 6.7 nM (S/N = 3). Moreover, we expect this work would open up a new field in the application of peroxydisulfate solution ECL for highly sensitive bioassays.
Dai, Hong; Chi, Yuwu; Wu, Xiaoping; Wang, Youmei; Wei, Mingdeng; Chen, Guonan
2010-02-15
A new biocompatible ECL biosensor based on enzyme/titanate nanotubes/chitosan composite film was developed for the determination of analytes in biological samples. In the fabrication of the new ECL biosensor, biocompatible titanate nanotubes (TNTs) and a model enzyme, i.e., choline oxidase (ChOX), were immobilized on a chitosan modified glassy carbon electrode (GCE) via electrostatic adsorption and covalent interaction, respectively. By this ECL biosensor, choline was enzymatically oxidized to hydrogen peroxide and detected by a sensitive luminol ECL system. The use of TNTs not only provided a biocompatible microenvironment for the immobilized enzyme, which resulted in an excellent stability and long lifetime of the ECL biosensor, but also exhibited great enhancement towards luminol ECL and thus led to a significant improvement in sensitivity of ECL biosensor. Satisfactory results were obtained when employing this biosensor in assaying the total choline in milk samples. The work would provide a common platform to develop various sensitive, selective and biocompatible ECL biosensors based on using enzyme/TNTs/CHIT composite films. Copyright 2009 Elsevier B.V. All rights reserved.
Zhang, Wei; Xiong, Huiwen; Chen, Miaomiao; Zhang, Xiuhua; Wang, Shengfu
2017-10-15
A novel molecularly imprinted electrochemiluminescence (MIP-ECL) sensor based on Ru(bpy) 3 2+ -doped silica nanoparticles (Ru@SiO 2 NPs) is developed for highly sensitive detection of fumonisin B 1 (FB 1 ). Gold-nanoparticles (AuNPs), Ru@SiO 2 NPs with chitosan (CS) composites and a molecularly imprinted polymer (MIP) are assembled on a glassy carbon electrode (GCE) to fabricate an ECL platform step by step. AuNPs could greatly promote the ECL intensity and improve the analytical sensitivity according to the localized surface plasmon resonance (LSPR) and the electrochemical effect. In this surface-enhanced electrochemiluminescence (SEECL) system, AuNPs work as the LSPR source to improve the ECL intensity and Ru@SiO 2 NPs are used as ECL luminophores. In the phosphate buffer solution (PBS), the evident anodic ECL of Ru@SiO 2 on the above working electrode is observed in the presence of the template molecule fumonisin B 1 (FB 1 ), which could act as the coreactant of Ru@SiO 2 NPs due to the amino group of FB 1 . When the template molecules were eluted from the MIP, little coreactant was left, resulting in an apparent decrease of ECL signal. After the MIP-ECL sensor was incubated in FB 1 solution, the template molecules rebound to the MIP surface, leading to the enhancement of ECL signal again. On the basis of these results, a facile MIP-ECL sensor has been successfully fabricated, which exhibited a linear range from 0.001 to 100ngmL -1 with a detection limit of 0.35pgmL -1 for FB 1 . Moreover, the proposed MIP-ECL sensor displayed an excellent application in real samples. Copyright © 2017 Elsevier B.V. All rights reserved.
Walt Disney visited Marshall Space Flight Center (MSFC)
NASA Technical Reports Server (NTRS)
1965-01-01
Walt Disney toured the West Test Area during his visit to the Marshall Space Flight Center on April 13, 1965. The three in center foreground are Karl Heimburg, Director, Test Division; Dr. von Braun, Director, MSFC; and Walt Disney. The Dynamic Test Stand with the S-1C stage being installed is in the background.
1965-02-01
Workers at the Marshall Space Flight Center (MSFC) move a facility test version of the Saturn IB launch vehicle's second stage, the S-IVB, to the J-2 test stand on February 10, 1965. Also known as a "battleship" because of its heavy, rugged construction, the non-flight, stainless-steel model was used to check out testing facilities at MSFC.
1965-02-01
A facility test version of the S-IVB, the second stage of the Saturn IB launch vehicle, sits in the Marshall Space Flight Center (MSFC) J-2 test stand on February 10, 1965. Also known as a "battleship" because of its heavy, rugged construction, the non-flight, stainless-steel model was used to check out testing facilities at MSFC.
Buscher, Hergen; Zhang, David; Nair, Priya
2017-10-01
Minimal evidence to guide haemostatic therapy for bleeding in extracorporeal life support (ECLS) has resulted in wide variability in practice. We aimed to show that a goal-directed algorithm incorporating results from thromboelastometry (TEM) is feasible and safe for the timely management of bleeding episodes in adult patients receiving ECLS. A pilot randomised controlled trial involving 16 adult patients who underwent ECLS, randomised over 10 months. The intervention group was treated according to a goal-directed algorithm based on TEM results during bleeding episodes. Apart from the intervention, both groups received standard care including conventional laboratory coagulation tests. Need for blood product transfusion, haemorrhagic and thromboembolic complications and survival. There was a statistically non-significant trend towards reduction in the amount of blood products transfused, occurrence of bleeding, and thrombotic complications, when comparing the intervention arm with the control arm. Survival to hospital discharge was 69%. A significant correlation was found between fibrinogen levels and FIBTEM clot firmness at 10 minutes (R = 0.812; P < 0.001); activated partial thromboplastin time and clotting time HEPTEM/INTEM ratio (R = -0.719; P < 0.001); and platelet count and EXTEM clot firmness at 10 minutes (R = 0.783; P < 0.001). TEM allows assessment for coagulation status in a timely manner and its use for the treatment of bleeding episodes in adult patients receiving ECLS appears feasible and safe. Clinical benefit should be investigated in larger multicentre randomised trials.
NASA Technical Reports Server (NTRS)
Johnson, J. D.; Winkler, G. W.
1976-01-01
The results are presented of a force test of a .88 percent scale model of the 142 inch solid rocket booster without protuberances, conducted in the MSFC high Reynolds number wind tunnel. The objective of this test was to obtain aerodynamic force data over a large range of Reynolds numbers. The test was conducted over a Mach number range from 0.4 to 3.5. Reynolds numbers based on model diameter (1.25 inches) ranged from .75 million to 13.5 million. The angle of attack range was from 35 to 145 degrees.
Extension of chronological lifespan by ScEcl1 depends on mitochondria in Saccharomyces cerevisiae.
Azuma, Kenko; Ohtsuka, Hokuto; Murakami, Hiroshi; Aiba, Hirofumi
2012-01-01
Ecl1, a product of the YGR146C gene in Saccharomyces cerevisiae, was identified as a factor involved in chronological lifespan. In this study we found evidence that the function of Ecl1 in the extension of chronological lifespan is dependent on mitochondrial function. The respiratory activity of cells increased when Ecl1 was overexpressed or cells were grown under calorie restriction, but there was no additive effect of calorie restriction and Ecl1 overexpression on increases in respiratory activity or on the extension of chronological lifespan. Based on these results, we propose that overexpression of Ecl1 has same effect as caloric restriction and that its function also depends on mitochondria, just like caloric restriction.
Senator Doug Jones (D-AL) Tour of MSFC Facilities
2018-02-22
Senator Doug Jones (D-AL.) and wife, Louise, tour Marshall Space Flight facilities. Steve Doering, manager, Stages Element, Space Launch System (SLS) program at MSFC, views the test stand 4693 where key SLS structural elements will be subjected to stress testing simulating space flight.
Surface evaluation of UV-degraded contamination
NASA Technical Reports Server (NTRS)
Connatser, Robert; Hadaway, James B.
1992-01-01
Three different areas of work were accomplished under this contract: (1) contamination testing and evaluation; (2) UV irradiation testing; and (3) surface evaluation testing. Contamination testing was generally performed in the In-Situ Contamination Effects Facility at Marshall Space Flight Center (MSFC). UV irradiation testing was also performed primarily at MSFC, utilizing facilities there. Finally, the surface evaluation was done at facilities at UAH Center for Applied Optics.
8. AERIAL VIEW OF THE EAST TEST AREA DURING A ...
8. AERIAL VIEW OF THE EAST TEST AREA DURING A SATURN I STATIC TEST. THIS PHOTO WAS TAKEN IN 1960 JUST PRIOR TO THE CHANGE OVER OF LAND, FACILITIES AND MISSION FROM ARMY/MICOM (MISSILE COMMAND) TO NASA/MSFC (MARSHALL SPACE FLIGHT CENTER). MSFC PHOTO LAB. - Marshall Space Flight Center, East Test Area, Dodd Road, Huntsville, Madison County, AL
1998-09-16
A team of engineers at Marshall Space Flight Center (MSFC) has designed, fabricated, and tested the first solar thermal engine, a non-chemical rocket that produces lower thrust but has better thrust efficiency than the chemical combustion engines. This segmented array of mirrors is the solar concentrator test stand at MSFC for firing the thermal propulsion engines. The 144 mirrors are combined to form an 18-foot diameter array concentrator. The mirror segments are aluminum hexagons that have the reflective surface cut into it by a diamond turning machine, which is developed by MSFC Space Optics Manufacturing Technology Center.
1965-04-01
S-IB-1, the first flight version of the Saturn IB launch vehicle's first stage (S-IB stage), undergoes a full-duration static firing in Saturn IB static test stand at the Marshall Space Flight Center (MSFC) on April 13, 1965. Developed by the MSFC and built by the Chrysler Corporation at the Michoud Assembly Facility (MAF) in New Orleans, Louisiana, the 90,000-pound booster utilized eight H-1 engines to produce a combined thrust of 1,600,000 pounds. Between April 1965 and July 1968, MSFC performed thirty-two static tests on twelve different S-IB stages.
Cheng, Lin; Wei, BingGuo; He, Ling Ling; Mao, Ling; Zhang, Jie; Ceng, JinXiang; Kong, DeRong; Chen, ChaDan; Cui, HanFeng; Hong, Nian; Fan, Hao
2017-02-01
A novel "off-On" electrogenerated chemiluminescence (ECL) biosensor has been developed for the detection of mercury(II) based on molecular recognition technology. The ECL mercury(II) biosensor comprises two main parts: an ECL substrate and an ECL intensity switch. The ECL substrate was made by modifying the complex of Ruthenium(II) tris-(bipyridine)(Ru(bpy) 3 2+ )/Cyclodextrins-Au nanoparticles(CD-AuNps)/Nafion on the surface of glass carbon electrode (GCE), and the ECL intensity switch is the single hairpin DNA probe designed according to the "molecular recognition" strategy which was functionalized with ferrocene tag at one end and attached to Cyclodextrins (CD) on modified GCE through supramolecular noncovalent interaction. We demonstrated that, in the absence of Hg(II) ion, the probe keeps single hairpin structure and resulted in a quenching of ECL of Ru(bpy) 3 2+ . Whereas, in the presence of Hg(II) ion, the probe prefers to form the T-Hg(II)-T complex and lead to an obvious recovery of ECL of Ru(bpy) 3 2+ , which provided a sensing platform for the detection of Hg(II) ion. Using this sensing platform, a simple, rapid and selective "off-On" ECL biosensor for the detection of mercury(II) with a detection limit of 0.1 nM has been developed. Copyright © 2016. Published by Elsevier Inc.
NASA Astrophysics Data System (ADS)
Hong, Kyeongsoo; Koo, Jae-Rim; Lee, Jae Woo; Kim, Seung-Lee; Lee, Chung-Uk; Park, Jang-Ho; Kim, Hyoun-Woo; Lee, Dong-Joo; Kim, Dong-Jin; Han, Cheongho
2018-05-01
We report the results of photometric observations for doubly eclipsing binaries OGLE-LMC-ECL-15674 and OGLE-LMC-ECL-22159, both of which are composed of two pairs (designated A&B) of a detached eclipsing binary located in the Large Magellanic Cloud. The light curves were obtained by high-cadence time-series photometry using the Korea Microlensing Telescope Network 1.6 m telescopes located at three southern sites (CTIO, SAAO, and SSO) between 2016 September and 2017 January. The orbital periods were determined to be 1.433 and 1.387 days for components A and B of OGLE-LMC-ECL-15674, respectively, and 2.988 and 3.408 days for OGLE-LMC-ECL-22159A and B, respectively. Our light curve solutions indicate that the significant changes in the eclipse depths of OGLE-LMC-ECL-15674A and B were caused by variations in their inclination angles. The eclipse timing diagrams of the A and B components of OGLE-LMC-ECL-15674 and OGLE-LMC-ECL-22159 were analyzed using 28, 44, 28, and 26 new times of minimum light, respectively. The apsidal motion period of OGLE-LMC-ECL-15674B was estimated by detailed analysis of eclipse timings for the first time. The detached eclipsing binary OGLE-LMC-ECL-15674B shows a fast apsidal period of 21.5 ± 0.1 years.
Using large-scale diagnostic quantities to investigate change in East Coast Lows
NASA Astrophysics Data System (ADS)
Ji, Fei; Evans, Jason P.; Argueso, Daniel; Fita, Lluis; Di Luca, Alejandro
2015-11-01
East Coast Lows (ECLs) are intense low-pressure systems that affect the eastern seaboard of Australia. They have attracted research interest for both their destructive nature and water supplying capability. Estimating the changes in ECLs in the future has a major impact on emergency response as well as water management strategies for the coastal communities on the east coast of Australia. In this study, ECLs were identified using two large-scale diagnostic quantities: isentropic potential vorticity (IPV) and geostrophic vorticity (GV), which were calculated from outputs of historical and future regional climate simulations from the NSW/ACT regional climate modelling (NARCliM) project. The diagnostic results for the historical period were evaluated against a subjective ECL event database. Future simulations using a high emission scenario were examined to estimate changes in frequency, duration, and intensity of ECLs. The use of a relatively high resolution regional climate model makes this the first study to examine future changes in ECLs while resolving the full range of ECL sizes which can be as small as 100-200 km in diameter. The results indicate that it is likely that there will be fewer ECLs, with weaker intensity in the future. There could also be a seasonal shift in ECLs from cool months to warm months. These changes have the potential to significantly impact the water security on the east coast of Australia.
NARC Rayon Replacement Program for the RSRM Nozzle, Phase IV Qualification and Implementation Status
NASA Technical Reports Server (NTRS)
Haddock, M. Reed; Wendel, Gary M.; Cook, Roger V.
2005-01-01
The Space Shuttle NARC Rayon Replacement Program has down-selected Enka rayon as a replacement for the obsolete NARC rayon in the nozzle carbon cloth phenolic (CCP) ablative insulators. Full qualification testing of the Enka rayon-based carbon cloth phenolic is underway, including processing, thmal/structural properties, and hot-fire subscale tests. Required thermal-structural capabilities, together with confidence in erosio/char performance in simulated and subscale hot fire tests such as Wright-Patterson Air Force Base Laser Hardened Materials Evaluation Laboratory testing, NASA-MSFC 24-inch motor tests, NASA-MSFC Solid Fuel Torch - Super Sonic Blast Tube, NASA-MSFC Plasma Torch Test Bed, ATK Thiokol Forty Pound Charge and NASA-MSFC MNASA justified the testing of the new Enka-rayon candidate on full-scale static test motors. The first RSRM full-scale static test motor nozzle, fabricated using the new Enka rayon-based CCP, was successfully demonstrated in June 2004. Two additional static test motors are planned with the new Enka rayon in the next two years along with additional A-basis property characterization. Process variation or "corner-of-the-box" testing together with cured and uncured aging studies are also planned as some of the pre-flight implementation activities with 5-year cured aging studies over-lapping flight hardware fabrication.
An electrochemiluminescent DNA sensor based on nano-gold enhancement and ferrocene quenching.
Yao, Wu; Wang, Lun; Wang, Haiyan; Zhang, Xiaolei; Li, Ling; Zhang, Na; Pan, Le; Xing, Nannan
2013-02-15
An electrochemiluminescent DNA (ECL-DNA) sensor based on nano-gold signal enhancement (i.e. gold nanoparticles, GNP) and ferrocene signal quenching was investigated. The Au electrode was first modified with GNPs through electrodeposition method, followed by subsequent immobilization of single-stranded probe DNA labeled with ruthenium complex. The resulting sensor produced a higher ECL signal due to its higher density of self-assembled probe DNAs on the surface. Upon the hybridization of probe DNA with complementary target DNA labeled with ferrocene, ECL intensity decreased significantly due to spatial separation of ECL label from the electrode surface. As a result, the ECL signal was simultaneously quenched by ferrocene. The effects of both nano-gold electrodeposition time and ferrocene on the performance of ECL-DNA sensor were studied in detail and possible reasons for these effects were suggested as well. The reported ECL-DNA sensor showed great sensitivity and may provide an alternative approach for DNA detection in diagnostics and gene analysis. Copyright © 2012 Elsevier B.V. All rights reserved.
Environmental Control and Life Support Systems Test Facility at MSFC
NASA Technical Reports Server (NTRS)
2001-01-01
The Marshall Space Flight Center (MSFC) is responsible for designing and building the life support systems that will provide the crew of the International Space Station (ISS) a comfortable environment in which to live and work. Scientists and engineers at the MSFC are working together to provide the ISS with systems that are safe, efficient, and cost-effective. These compact and powerful systems are collectively called the Environmental Control and Life Support Systems, or simply, ECLSS. In this photograph, the life test area on the left of the MSFC ECLSS test facility is where various subsystems and components are tested to determine how long they can operate without failing and to identify components needing improvement. Equipment tested here includes the Carbon Dioxide Removal Assembly (CDRA), the Urine Processing Assembly (UPA), the mass spectrometer filament assemblies and sample pumps for the Major Constituent Analyzer (MCA). The Internal Thermal Control System (ITCS) simulator facility (in the module in the right) duplicates the function and operation of the ITCS in the ISS U.S. Laboratory Module, Destiny. This facility provides support for Destiny, including troubleshooting problems related to the ITCS.
Solar Thermal Propulsion Test Facility at MSFC
NASA Technical Reports Server (NTRS)
1999-01-01
This photograph shows an overall view of the Solar Thermal Propulsion Test Facility at the Marshall Space Flight Center (MSFC). The 20-by 24-ft heliostat mirror, shown at the left, has dual-axis control that keeps a reflection of the sunlight on an 18-ft diameter concentrator mirror (right). The concentrator mirror then focuses the sunlight to a 4-in focal point inside the vacuum chamber, shown at the front of concentrator mirror. Researchers at MSFC have designed, fabricated, and tested the first solar thermal engine, a non-chemical rocket engine that produces lower thrust but has better thrust efficiency than chemical a combustion engine. MSFC turned to solar thermal propulsion in the early 1990s due to its simplicity, safety, low cost, and commonality with other propulsion systems. Solar thermal propulsion works by acquiring and redirecting solar energy to heat a propell nt. As part of MSFC's Space Transportation Directorate, the Propulsion Research Center serves as a national resource for research of advanced, revolutionary propulsion technologies. The mission is to move the Nation's capabilities beyond the confines of conventional chemical propulsion into an era of aircraft-like access to Earth-orbit, rapid travel throughout the solar system, and exploration of interstellar space.
Summary of Recent Inducer Testing at MSFC and Future Plans
NASA Technical Reports Server (NTRS)
Skelley, Stephen
2003-01-01
This viewgraph presentation covers water flow tests on the RS-83 Main LOX Inducer for the Space Shuttle Main Engine (SSME). The presentation lists recent water tests on the SSME liquid oxygen (LOX) pump inducer, includes images and diagrams of the water test facility at Marshall Space Flight Center (MSFC), profiles inducer hydrodynamic forces, and diagrams the performance of the RS-83 inducer.
1960-01-01
Pictured is one of the earliest testing of the Saturn I S-I (first) stage, with a cluster of eight H-1 engines, at the Marshall Space Flight Center (MSFC). It was a part of the test program to prove out the clustered-booster concept. MSFC was responsible for designing and development the Saturn launch vehicles.
1967-10-01
Workmen at the Marshall Space Flight Center's (MSFC's) dock on the Ternessee River unload S-IB-211, the flight version of the Saturn IB launch vehicle's first stage, from the NASA barge Palaemon. Between December 1967 and April 1968, the stage would undergo seven static test firings in MSFC's S-IB static test stand.
ERIC Educational Resources Information Center
National Center for Rural Early Childhood Learning Initiatives - Mississippi State University Early Childhood Institute, 2005
2005-01-01
The National Center for Rural Early Childhood Learning Initiatives at Mississippi State University, known as Rural Early Childhood, commissioned the nonpartisan research organization Child Trends to conduct such an analysis of the ECLS-K and ECLS-B baseline data, focusing on selected indicators related to child and family health and socioeconomic…
NASA Technical Reports Server (NTRS)
Burns, H. D.; Mitchell, M. A.; McMillian, J. H.; Farner, B. R.; Harper, S. A.; Peralta, S. F.; Lowrey, N. M.; Ross, H. R.; Juarez, A.
2015-01-01
Since the 1990's, NASA's rocket propulsion test facilities at Marshall Space Flight Center (MSFC) and Stennis Space Center (SSC) have used hydrochlorofluorocarbon-225 (HCFC-225), a Class II ozone-depleting substance, to safety clean and verify the cleanliness of large scale propulsion oxygen systems and associated test facilities. In 2012 through 2014, test laboratories at MSFC, SSC, and Johnson Space Center-White Sands Test Facility collaborated to seek out, test, and qualify an environmentally preferred replacement for HCFC-225. Candidate solvents were selected, a test plan was developed, and the products were tested for materials compatibility, oxygen compatibility, cleaning effectiveness, and suitability for use in cleanliness verification and field cleaning operations. Honewell Soltice (TradeMark) Performance Fluid (trans-1-chloro-3,3, 3-trifluoropropene) was selected to replace HCFC-225 at NASA's MSFC and SSC rocket propulsion test facilities.
Yang, Huiyun; Wang, Haijun; Xiong, Chengyi; Chai, Yaqin; Yuan, Ruo
2018-05-22
In this work, poly[9,9-dioctylfluorenyl-2,7-diyl] (PFO) dots is discovered to display an appealing dual enhancement effect for the electrochemiluminescence (ECL) system of N-(aminobutyl)-N-(ethylisoluminol)/hydrogen peroxide (ABEI/H 2 O 2 ), which not only enhances the ECL intensity of ABEI but also catalyzes decomposition of H 2 O 2 to further amplify the ECL signal of ABEI. Owing to the electronegative property of PFO dots, electropositive ABEI-PEI as ECL reagent could be adsorbed on their surface and thus form a novel luminescence emitter (ABEI-PEI-PFO dots) with high ECL efficiency based on electrostatic attraction. Meanwhile, the water solubility and stability of this emitter are improved in virtue of the amine-rich property of ECL reagent (ABEI-PEI), which could increase the luminous efficiency of ECL reaction in aqueous solution. To increase the electron transfer efficiency, Pt nanoparticles (PtNPs) supported on reduced graphene oxide nanosheets (RGOs) via a onepot synthetic strategy are chosen as immobilizing platform for the ECL emitter (ABEI-PEI-PFO dots). Herein, the obtained dual-amplifed ABEI-PEI-PFO dots-RGOs/PtNPs complex is served as an ideal nanocarrier to capture detection antibody (Ab 2 ). According to sandwiched immunoreaction, a highly sensitive ECL immunosensor is constructed for the detection of kidney injury molecule-1 (KIM-1) with a linearity from 50 fg mL -1 to 1 ng mL -1 and a detection limit of 16.7 fg mL -1 . The developed ECL emitter combining dual amplified property for signal enhancement purpose would provide new thought and potential for sensitive bioanalysis and clinical application. Copyright © 2018 Elsevier B.V. All rights reserved.
Spatial-resolved electrochemiluminescence ratiometry based on bipolar electrode for bioanalysis.
Wang, Yin-Zhu; Zhao, Wei; Dai, Pan-Pan; Lu, Hai-Jie; Xu, Jing-Juan; Pan, Jing; Chen, Hong-Yuan
2016-12-15
Herein, a spatial-resolved electrochemiluminescene (ECL) ratiometry based on a closed biopolar electrode (BPE) is reported for the highly sensitive detection of prostate specific antigen (PSA). Au@g-C3N4 NCs as one ECL emitter were firstly coated on the cathode of BPE, while the anode of the BPE served for calibration via another ECL substance, Ru(bpy)3(2+). The electroneutrality across the BPE makes the reactions on each pole of BPE electrically coupled. Thus one electrochemical sensing reaction at one pole of BPE could be quantified at both ends. A composite, Pt-PAMAM-DNAzyme was assembled on the surface of cathode via DNA hybridization between probe DNA and PSA aptamer. It acted as an ECL quencher of g-C3N4 via resonance energy transfer (RET) and catalyzing the reduction of O2, the co-reactant of g-C3N4. Meanwhile, it could promote the ECL of Ru(bpy)3(2+) at anode, since the catalytic reduction of O2 at the cathode increased the faradiac current flowing through the BPE. Based on this signal composite, an ECL "off-on" phenomenon was observed at the cathode, after Pt-PAMAM-DNAzyme was "peeled off" by PSA. Conversely, at the anode, an "on-off" ECL changing was obtained. Therefore, a sensitive ratiometry for PSA detection was achieved with a linear range from 0.10 to 200ng/mL. Since the two ECL emitters were physically separated, the ratiometric system was relatively simple and neither optical filters nor spectrometer were required. The strategy combining the ECL ratiometry and BPE broadens the applications of BPE-ECL and shows good perspective in clinical application. Copyright © 2016 Elsevier B.V. All rights reserved.
CdZnTeS quantum dots based electrochemiluminescent image immunoanalysis.
Liang, Xiu-Li; Bao, Ning; Luo, Xiliang; Ding, Shou-Nian
2018-06-05
In this work, quaternary CdZnTeS quantum dots (QDs) with a particularly strong electrochemiluminescence (ECL) were synthesized as ECL signal labels. The strong ECL signals can be obtained at both cathode and anode with the ECL efficiencies of 19.78% and 1.62%, respectively. The sandwich-structured ECL immunosensors for the detection of alpha-fetoprotein (AFP) and cancer antigen 125 (CA125) were accomplished with direct ECL image analysis. Under optimal conditions, the QDs-based ECL image immunoanalysis possessed good linearity from 0.5 ng/mL to 20 ng/mL for AFP and from 20 U/mL to 500 U/mL for CA125 with the detection limit of 0.1 ng/mL and 6 U/mL, respectively (S/N = 3), and the lower detection limit obtained by photomultiplier tube were 0.1 fg/mL for AFP and 0.03 mU/mL for CA125 with the wide dynamic range from 0.5 fg/mL to 20 ng/mL and from 0.1 mU/mL to 500 U/mL, respectively (S/N = 3). Furthermore, the ECL immunoanalysis was evaluated with commercial enzyme-linked immunosorbent assay in human serum samples. The good results indicated that CdZnTeS QDs-based ECL biosensor has great potential for fast biomedical screening and multi-assays in clinical diagnosis. Copyright © 2018 Elsevier B.V. All rights reserved.
Extracorporeal Life Support Bridge to Ventricular Assist Device: The Double Bridge Strategy.
Marasco, Silvana F; Lo, Casey; Murphy, Deirdre; Summerhayes, Robyn; Quayle, Margaret; Zimmet, Adam; Bailey, Michael
2016-01-01
In patients requiring left ventricular assist device (LVAD) support, it can be difficult to ascertain suitability for long-term mechanical support with LVAD and eventual transplantation. LVAD implantation in a shocked patient is associated with increased morbidity and mortality. Interest is growing in the utilization of extracorporeal life support (ECLS) as a bridge-to-bridge support for these critically unwell patients. Here, we reviewed our experience with ECLS double bridging. We hypothesized that ECLS double bridging would stabilize end-organ dysfunction and reduce ventricular assist device (VAD) implant perioperative mortality. We conducted a retrospective review of prospectively collected data for 58 consecutive patients implanted with a continuous-flow LVAD between January 2010 and December 2013 at The Alfred Hospital, Melbourne, Victoria, Australia. Twenty-three patients required ECLS support pre-LVAD while 35 patients underwent LVAD implantation without an ECLS bridge. Preoperative morbidity in the ECLS bridge group was reflected by increased postoperative intensive care duration, blood loss, blood product use, and postoperative renal failure, but without negative impact upon survival when compared with the no ECLS group. ECLS stabilization improved end-organ function pre-VAD implant with significant improvements in hepatic and renal dysfunction. This series demonstrates that the use of ECLS bridge to VAD stabilizes end-organ dysfunction and reduces VAD implant perioperative mortality from that traditionally reported in these "crash and burn" patients. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
NASA Technical Reports Server (NTRS)
1998-01-01
NASA engineers successfully tested a Russian-built rocket engine on November 4, 1998 at the Marshall Space Flight Center (MSFC) Advanced Engine Test Facility, which had been used for testing the Saturn V F-1 engines and Space Shuttle Main engines. The MSFC was under a Space Act Agreement with Lockheed Martin Astronautics of Denver to provide a series of test firings of the Atlas III propulsion system configured with the Russian-designed RD-180 engine. The tests were designed to measure the performance of the Atlas III propulsion system, which included avionics and propellant tanks and lines, and how these components interacted with the RD-180 engine. The RD-180 is powered by kerosene and liquid oxygen, the same fuel mix used in Saturn rockets. The RD-180, the most powerful rocket engine tested at the MSFC since Saturn rocket tests in the 1960s, generated 860,000 pounds of thrust.
ERIC Educational Resources Information Center
Rock, Donald A.; Pollack, Judith M.
2002-01-01
This report documents the design, development, and psychometric characteristics of the assessment instruments used in the Early Childhood Longitudinal Study-Kindergarten Class of 1998-99 (ECLS-K). The ECLS-K is sponsored by the U.S. Department of Education, National Center for Education Statistics. The ECLS-K was designed to assess the…
Extracorporeal life support in preoperative and postoperative heart transplant management.
Bermudez, Christian A; McMullan, D Michael
2017-10-01
Increased experience with extracorporeal life support (ECLS) as a mode of cardiac support has expanded its use to diverse patient populations including patients requiring a bridge to heart transplantation and patients requiring posttransplant support for primary graft dysfunction (PGD). The use of ECLS is associated with acceptable outcomes in well-selected patients. While outcomes with the use of extracorporeal membrane oxygenation (ECMO) as a bridge to heart transplant have been variable, several series have confirmed the safe use of ECLS to stabilize patients prior to left ventricular assist device (LVAD) implantation. These patients are then considered later, when in stable condition, for heart transplant. When ECLS is used prior to heart transplant, mortality is greatest during the first 6 months posttransplant. Patients who are alive 6 months after transplant appear to have similar survival rates as patients who were not supported with ECLS prior to transplant. ECLS support is a reliable therapeutic option for severe PGD and early graft failure after heart transplantation. In patients who require support for severe PGD, venoarterial-ECMO appears to result in better clinical outcomes than LVAD support. ECLS use for PGD after heart transplant continues to be the first line of support. Further studies are necessary to understand the optimal role of ECLS in heart transplantation.
Recent development of electrochemiluminescence sensors for food analysis.
Hao, Nan; Wang, Kun
2016-10-01
Food quality and safety are closely related to human health. In the face of unceasing food safety incidents, various analytical techniques, such as mass spectrometry, chromatography, spectroscopy, and electrochemistry, have been applied in food analysis. High sensitivity usually requires expensive instruments and complicated procedures. Although these modern analytical techniques are sensitive enough to ensure food safety, sometimes their applications are limited because of the cost, usability, and speed of analysis. Electrochemiluminescence (ECL) is a powerful analytical technique that is attracting more and more attention because of its outstanding performance. In this review, the mechanisms of ECL and common ECL luminophores are briefly introduced. Then an overall review of the principles and applications of ECL sensors for food analysis is provided. ECL can be flexibly combined with various separation techniques. Novel materials (e.g., various nanomaterials) and strategies (e.g., immunoassay, aptasensors, and microfluidics) have been progressively introduced into the design of ECL sensors. By illustrating some selected representative works, we summarize the state of the art in the development of ECL sensors for toxins, heavy metals, pesticides, residual drugs, illegal additives, viruses, and bacterias. Compared with other methods, ECL can provide rapid, low-cost, and sensitive detection for various food contaminants in complex matrixes. However, there are also some limitations and challenges. Improvements suited to the characteristics of food analysis are still necessary.
Steck, Andrea K; Fouts, Alexandra; Miao, Dongmei; Zhao, Zhiyuan; Dong, Fran; Sosenko, Jay; Gottlieb, Peter; Rewers, Marian J; Yu, Liping
2016-07-01
Relatives with single positive islet autoantibodies have a much lower risk of progression to diabetes than those with multiple autoantibodies. TrialNet subjects positive for single autoantibody to insulin (mIAA) (n = 50) or single autoantibody to glutamic acid decarboxylase (GADA) (n = 50) were analyzed using new electrochemiluminescence (ECL) assays (ECL-IAA and ECL-GADA, respectively) at their initial visit and longitudinally over time. Affinity assays were performed on a subset of single autoantibody-positive subjects at initial and most recent visits. After a mean follow-up of 5.3 years, 20 subjects developed type 1 diabetes. Among either single GADA or single mIAA subjects, those who were positive in the ECL assay showed higher affinity at the initial visit, and affinity results stayed consistent over time. No converting events from low to high or high to low affinity were seen over time. Confirmed positivity for ECL is associated with high affinity and can help staging of risk for type 1 diabetes in single autoantibody-positive subjects.
1988-03-21
The Marshall Space Flight Center (MSFC) successfully test fired the third in a series of Transient Pressure Test Articles (TPTA) in its east test area. The test article was a short-stack solid rocket motor 52-feet long and 12-feet in diameter. The TPTA tests were designed to evaluate the effects of temperature, pressure and external loads encountered by the SRM, primarily during ignition transients. Instrumentation on the motor recorded approximately 1,000 charnels of data to verify the structural performance, thermal response, sealing capability of the redesign field, and case-to-nozzle joints. The TPTA test stand, 14-feet wide by 26-feet long by 33-feet high, was built in 1987. The TPTA series was a joint effort among Morton Thiokol, Inc., United Space Boosters, Inc., Wyle Laboratories, and MSFC. Wyle Laboratories conducted the tests for the MSFC, which manages the redesigned SRM program for NASA.
1998-11-04
NASA engineers successfully tested a Russian-built rocket engine on November 4, 1998 at the Marshall Space Flight Center (MSFC) Advanced Engine Test Facility, which had been used for testing the Saturn V F-1 engines and Space Shuttle Main engines. The MSFC was under a Space Act Agreement with Lockheed Martin Astronautics of Denver to provide a series of test firings of the Atlas III propulsion system configured with the Russian-designed RD-180 engine. The tests were designed to measure the performance of the Atlas III propulsion system, which included avionics and propellant tanks and lines, and how these components interacted with the RD-180 engine. The RD-180 is powered by kerosene and liquid oxygen, the same fuel mix used in Saturn rockets. The RD-180, the most powerful rocket engine tested at the MSFC since Saturn rocket tests in the 1960s, generated 860,000 pounds of thrust.
NASA Technical Reports Server (NTRS)
Gradl, Paul
2016-01-01
NASA Marshall Space Flight Center (MSFC) has been advancing dynamic optical measurement systems, primarily Digital Image Correlation, for extreme environment rocket engine test applications. The Digital Image Correlation (DIC) technology is used to track local and full field deformations, displacement vectors and local and global strain measurements. This technology has been evaluated at MSFC through lab testing to full scale hotfire engine testing of the J-2X Upper Stage engine at Stennis Space Center. It has been shown to provide reliable measurement data and has replaced many traditional measurement techniques for NASA applications. NASA and AMRDEC have recently signed agreements for NASA to train and transition the technology to applications for missile and helicopter testing. This presentation will provide an overview and progression of the technology, various testing applications at NASA MSFC, overview of Army-NASA test collaborations and application lessons learned about Digital Image Correlation.
NASA Technical Reports Server (NTRS)
Hart, J. F.
1973-01-01
MSFC-STD-486, Threaded Fasteners, Torque Limits For, is a relatively new standard that has not had much user experience. This test was run to provide such experience and verify the values in MSFC-STD-486. This was accomplished by plotting torque-tension curves on aluminum and alloy steel aircraft quality bolts and nuts through 1/2 inch in diameter.
Diagnosis and treatment of ECL cell tumors.
Cadiot, G.; Cattan, D.; Mignon, M.
1998-01-01
The diagnosis of ECL-omas is easy to perform. In patients with Zollinger-Ellison syndrome (ZES), ECL-omas are almost always observed in the setting of multiple endocrine neoplasia type I. In patients without ZES, the first step is to discard non-gastrin-related sporadic ECL-omas whose prognosis is poor. By contrast, prognosis of ECL-omas in patients with ZES or chronic atrophic gastritis is good. Metastases are rare, and tumor-related deaths are exceptional. In both conditions, ECL-omas measuring less than 1 cm should be treated by endoscopic polypectomy and survey. Treatment modalities (surgery, endoscopic polypectomy) for larger tumors are still discussed. The impact of endoscopic ultrasonography on the therapeutic decision has not yet been evaluated. Considering the good prognosis of these tumors, aggressive surgery could be limited to selected patients. Multicentric studies should be undertaken to determine the best treatment modalities. PMID:10461362
Desebbe, O; Rosamel, P; Henaine, R; Vergnat, M; Farhat, F; Dubien, P Y; Bastien, O
2013-04-01
Describing the experience of a referral center for interhospital patients transport treated with extracorporeal circulatory or respiratory support (ECLS), the difficulties encountered and the results obtained. Retrospective and observational study. All patients with respiratory or circulatory failure accepted for extracorporeal assistance for which routine medical transport was life threatening. A descriptive analysis was performed (median and interquartile deviation). Comparison of biological data was performed using a non-parametric Wilcoxon test and 5 years overall survival was determined by a Kaplan-Meier analysis. Over a 55-month period, 29 patients were selected for transportation under ECMO or ECLS. Indication was respiratory failure in 38 % of cases, hemodynamic instability in 52 % of cases and combined symptoms in 10 % of cases. Average duration of transportation was 40 km (9-64 km). No complication related to transport was observed. Incidence of intrahospital death was 57 %. There was no correlation between death and indication of ECLS. Five-year survival was 55 % and 39 % for venovenous and arteriovenous ECLS, respectively. In our experience, interhospital transport of patients under ECMO is feasible in satisfactory conditions of safety with trained team and standard procedures. Copyright © 2013 Société française d’anesthésie et de réanimation (Sfar). Published by Elsevier SAS. All rights reserved.
NASA Astrophysics Data System (ADS)
Ma, Meng-Nan; Zhang, Xia; Zhuo, Ying; Chai, Ya-Qin; Yuan, Ruo
2015-01-01
A novel electrochemiluminescent (ECL) signal tag of Au nanoparticles capped by 3,4,9,10-perylene tetracarboxylic acid-thiosemicarbazide functionalized C60 nanocomposites (AuNPs/TSC-PTC/C60NPs) was developed for thrombin (TB) aptasensor construction based on the peroxydisulfate/oxygen (S2O82-/O2) system. For signal tag fabrication, the C60 nanoparticles (C60NPs) were prepared and then coated with 3,4,9,10-perylene tetracarboxylic acid (PTCA) by π-π stacking interactions. Afterwards, thiosemicarbazide (TSC) was linked with PTCA functionalized C60NPs via amidation for further assembling Au nanoparticles (AuNPs). Finally, detection aptamer of thrombin (TBA 2) was labeled on the ECL signal amplification tag of AuNPs/TSC-PTC/C60NPs. Herein, TSC, with the active groups of -NH2 and -SH, was selected and introduced into the ECL S2O82-/O2 system for the first time, which could not only offer the active groups of -SH to absorb AuNPs for TBA 2 anchoring but also remarkably enhance the ECL signal of the S2O82-/O2 system by the formation of TSC-PTC/C60NPs for signal amplification. Meanwhile, the sensing interface of a glassy carbon electrode (GCE) was modified by AuNPs/graphene (AuNPs/GR) nanocomposites with the large specific surface area and the active sites, followed by immobilization of thiol-terminated thrombin capture aptamer (TBA 1). With the formation of the sandwich-type structure of TBA 1, TB, and TBA 2 signal probes, a desirable enhanced ECL signal was measured in the testing buffer of an S2O82-/O2 solution for detecting TB. The aptasensor exhibited a good linear relationship for TB detection in the range of 1 × 10-5-10 nM with a detection limit of 3.3 fM.A novel electrochemiluminescent (ECL) signal tag of Au nanoparticles capped by 3,4,9,10-perylene tetracarboxylic acid-thiosemicarbazide functionalized C60 nanocomposites (AuNPs/TSC-PTC/C60NPs) was developed for thrombin (TB) aptasensor construction based on the peroxydisulfate/oxygen (S2O82-/O2) system. For signal tag fabrication, the C60 nanoparticles (C60NPs) were prepared and then coated with 3,4,9,10-perylene tetracarboxylic acid (PTCA) by π-π stacking interactions. Afterwards, thiosemicarbazide (TSC) was linked with PTCA functionalized C60NPs via amidation for further assembling Au nanoparticles (AuNPs). Finally, detection aptamer of thrombin (TBA 2) was labeled on the ECL signal amplification tag of AuNPs/TSC-PTC/C60NPs. Herein, TSC, with the active groups of -NH2 and -SH, was selected and introduced into the ECL S2O82-/O2 system for the first time, which could not only offer the active groups of -SH to absorb AuNPs for TBA 2 anchoring but also remarkably enhance the ECL signal of the S2O82-/O2 system by the formation of TSC-PTC/C60NPs for signal amplification. Meanwhile, the sensing interface of a glassy carbon electrode (GCE) was modified by AuNPs/graphene (AuNPs/GR) nanocomposites with the large specific surface area and the active sites, followed by immobilization of thiol-terminated thrombin capture aptamer (TBA 1). With the formation of the sandwich-type structure of TBA 1, TB, and TBA 2 signal probes, a desirable enhanced ECL signal was measured in the testing buffer of an S2O82-/O2 solution for detecting TB. The aptasensor exhibited a good linear relationship for TB detection in the range of 1 × 10-5-10 nM with a detection limit of 3.3 fM. Electronic supplementary information (ESI) available. See DOI: 10.1039/c4nr05918b
Redstone Test Stand Accepted Into National Register of Historical Places
NASA Technical Reports Server (NTRS)
1976-01-01
On October 02, 1976, Marshall Space Flight Center's (MSFC) Redstone test stand was received into the National Registry of Historical Places. Photographed in front of the Redstone test stand are Dr. William R. Lucas, MSFC Center Director from June 15, 1974 until July 3, 1986, as he is accepting a certificate of registration from Madison County Commission Chairman James Record, and Huntsville architect Harvie Jones.
The environmental control and life-support system for a lunar base: What drives its design
NASA Technical Reports Server (NTRS)
Hypes, Warren D.; Hall, John B., Jr.
1992-01-01
The purpose of this paper is to identify and briefly discuss some of the ground rules and mission scenario details that become drivers of the environmental control and life support (ECLS) system design and of the logistics related to the design. This paper is written for mission planners and non-ECLS system engineers to inform them of the details that will be important to the ECLS engineer when the design phase is reached. In addition, examples illustrate the impact of some selected mission characteristics on the logistics associated with ECLS systems. The last section of this paper focuses on the ECLS system technology development sequence and highlights specific portions that need emphasis.
2001-07-01
This photograph shows two Marshall Space Flight Center (MSFC) engineers, Mark Vaccaro (left) and Ken Welzyn, testing electrodynamic tethers in the MSFC Tether Winding and Spark Testing Facility. For 4 years, MSFC and industry partners have been developing the Propulsive Small Expendable Deployer System experiment, called ProSEDS. ProSEDS will test electrodynamic tether propulsion technology. Electrodynamic tethers are long, thin wires that collect electrical current when passing through a magnetic field. The tether works as a thruster as a magnetic field exerts a force on a current-carrying wire. Since electrodynamic tethers require no propellant, they could substantially reduce the weight of the spacecraft and provide a cost-effective method of reboosting spacecraft. The initial flight of ProSEDS is scheduled to fly aboard an Air Force Delta II rocket in the summer of 2002. In orbit, ProSEDS will deploy from a Delta II second stage. It will be a 3.1-mile (5 kilometer) long, ultrathin base-wire tether cornected with a 6.2-mile (10 kilometer) long non-conducting tether. This photograph shows Less Johnson, a scientist at MSFC, inspecting the nonconducting part of a tether as it exits a deployer similar to the one to be used in the ProSEDS experiment. The ProSEDS experiment is managed by the Space Transportation Directorate at MSFC.
Repeatability and uncertainty analyses of NASA/MSFC light gas gun test data
NASA Technical Reports Server (NTRS)
Schonberg, William P.; Cooper, David
1993-01-01
This Final Report presents an overview of the impact tests performed at NASA/MSFC in the time period 1985 to 1991 and the results of phenomena repeatability and data uncertainty studies performed using the information obtained from those tests. An analysis of the data from over 400 tests conducted between 1989 and 1991 was performed to generate a database to supplement the Hypervelocity Impact Damage Database developed under a previous effort.
ERIC Educational Resources Information Center
Tourangeau, Karen; Nord, Christine; Lê, Thanh; Sorongon, Alberto G.; Hagedorn, Mary C.; Daly, Peggy; Najarian, Michelle
2015-01-01
This manual provides guidance and documentation for users of the kindergarten (or base year) data of the Early Childhood Longitudinal Study, Kindergarten Class of 2010-11 (ECLS-K:2011). It begins with an overview of the ECLS-K:2011. Subsequent chapters provide details on the study data collection instruments and methods; the direct and indirect…
ERIC Educational Resources Information Center
Tourangeau, Karen; Nord, Christine; Le, Thanh; Sorongon, Alberto G.; Najarian, Michelle
2009-01-01
This manual provides guidance and documentation for users of the eighth-grade data of the Early Childhood Longitudinal Study, Kindergarten Class of 1998-99 (ECLS-K). It begins with an overview of the ECLS-K study. Subsequent chapters provide details on the instruments and measures used, the sample design, weighting procedures, response rates, data…
Costa, Rúbia S; Carvalho, Lucas P; Campos, Taís M; Magalhães, Andréa S; Passos, Sara T; Schriefer, Albert; Silva, Juliana A; Lago, Ednaldo; Paixão, Camilla S; Machado, Paulo; Scott, Phillip; Carvalho, Edgar M
2018-02-14
Early cutaneous leishmaniasis (ECL) is characterized by a nonulcerated papular lesion and illness duration less than 30 days. Approximately 4 weeks later, the cutaneous leishmaniasis (CL) ulcers appear. We were surprised to find that failure after antimony therapy (Sb5) is higher in ECL than CL. We hypothesize that the inflammatory response in ECL patients may increase during Sb5 therapy, which leads to treatment failure. A cohort of 44 ECL patients infected by Leishmania braziliensis was established to evaluate the response to Sb5 and to compare immunologic responses in ECL patients with CL and healthy subjects. A hierarchical clustering based on cytokine levels showed a weak positive correlation between proinflammatory cytokine levels and those patients that failed Sb5 treatment. Although Sb5 therapy decreased interferon-γ and tumor necrosis factor levels in CL patients, we were surprised to find that an increase in these cytokines was observed in ECL patients. Moreover, interleukin (IL)-10 was less able to down-modulate immune responses in ECL. The enhanced production of proinflammatory cytokines, due in part to the decreased ability of IL-10 to down-modulate immune response during therapy in ECL, promotes the development and persistence of leishmania ulcer despite antimony therapy. © The Author(s) 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.
Liu, Jia-Li; Tang, Zhi-Ling; Zhang, Jia-Qi; Chai, Ya-Qin; Zhuo, Ying; Yuan, Ruo
2018-04-17
The electrochemiluminescence (ECL) properties of polycyclic aromatic hydrocarbons (PAHs) are excellent on account of the high photoluminescence quantum yield. However, the poor solubility and radical instability of PAHs in the aqueous solution severely restricted further biological application. Here 9,10-diphenylanthracene (DPA) nanoblocks (NBs) with good dispersibility and stability in aqueous solution were prepared according to morphology-controlled technology employing water-soluble polymers as a protectant. Furthermore, an ECL "off-on" switch biosensor was developed based on a novel ECL ternary system with DPA NBs as luminophore, dissolved O 2 as coreactant, and Pt-Ag alloy nanoflowers as the coreaction accelerator, which achieved a high-intense initial ECL signal. Subsequently, the Fc-DNA as ECL signal quencher was assembled on the electrode surface to quench the initial ECL signal for a "signal-off" state. Meanwhile, DNA swing arm was modified on the electrode surface for one-step DNA walker amplification. Interestingly, in the presence of miRNA-141 and T7 Exo, the one-step DNA walker amplification was executed to recover a strong ECL signal as a "signal-on" state by the digestion of Fc-DNA. Thus the developed ECL "off-on" switch biosensor possesses a detection limit down to 29.5 aM for ultrasensitive detection of miRNA-141, which is expected to be applicable to the detection of miRNA in clinic tumor cells.
Liu, Jing; Cui, Meirong; Zhou, Hong; Zhang, Shusheng
2016-01-01
A novel ternary composite of hemin-graphene-Au nanorods (H-RGO-Au NRs) with high electrocatalytic activity was synthesized by a simple method. And this ternary composite was firstly used in construction of electrochemiluminescence (ECL) immunosensor due to its double-quenching effect of quantum dots (QDs). Based on the high electrocatalytic activity of ternary complexes for the reduction of H2O2 which acted as the coreactant of QDs-based ECL, as a result, the ECL intensity of QDs decreased. Besides, due to the ECL resonance energy transfer (ECL-RET) strategy between the large amount of Au nanorods (Au NRs) on the ternary composite surface and the CdS:Eu QDs, the ECL intensity of QDs was further quenched. Based on the double-quenching effect, a novel ultrasensitive ECL immunoassay method for detection of carcinoembryonic antigen (CEA) which is used as a model biomarker analyte was proposed. The designed immunoassay method showed a linear range from 0.01 pg mL−1 to 1.0 ng mL−1 with a detection limit of 0.01 pg mL−1. The method showing low detection limit, good stability and acceptable fabrication reproducibility, provided a new approach for ECL immunoassay sensing and significant prospect for practical application. PMID:27460868
NASA Technical Reports Server (NTRS)
1998-01-01
NASA engineers successfully tested a Russian-built rocket engine on November 4, 1998 at the Marshall Space Flight Center (MSFC) Advanced Engine Test Facility, which had been used for testing the Saturn V F-1 engines and Space Shuttle Main engines. The MSFC was under a Space Act Agreement with Lockheed Martin Astronautics of Denver to provide a series of test firings of the Atlas III propulsion system configured with the Russian-designed RD-180 engine. The tests were designed to measure the performance of the Atlas III propulsion system, which included avionics and propellant tanks and lines, and how these components interacted with the RD-180 engine. The RD-180 is powered by kerosene and liquid oxygen, the same fuel mix used in Saturn rockets. The RD-180, the most powerful rocket engine tested at the MSFC since Saturn rocket tests in the 1960s, generated 860,000 pounds of thrust. The test was the first test ever anywhere outside Russia of a Russian designed and built engine.
NASA Technical Reports Server (NTRS)
Ray, Charles D.; Carrasquillo, Robyn L.; Minton-Summers, Silvia
1997-01-01
This paper provides a summary of current work accomplished under technical task agreement (TTA) by the Marshall Space Flight Center (MSFC) regarding the Environmental Control and Life Support System (ECLSS) as well as future planning activities in support of the International Space Station (ISS). Current activities include ECLSS computer model development, component design and development, subsystem integrated system testing, life testing, and government furnished equipment delivered to the ISS program. A long range plan for the MSFC ECLSS test facility is described whereby the current facility would be upgraded to support integrated station ECLSS operations. ECLSS technology development efforts proposed to be performed under the Advanced Engineering Technology Development (AETD) program are also discussed.
Avionics Simulation, Development and Software Engineering
NASA Technical Reports Server (NTRS)
2002-01-01
During this reporting period, all technical responsibilities were accomplished as planned. A close working relationship was maintained with personnel of the MSFC Avionics Department Software Group (ED14), the MSFC EXPRESS Project Office (FD31), and the Huntsville Boeing Company. Accomplishments included: performing special tasks; supporting Software Review Board (SRB), Avionics Test Bed (ATB), and EXPRESS Software Control Panel (ESCP) activities; participating in technical meetings; and coordinating issues between the Boeing Company and the MSFC Project Office.
Comparison of unusual carbon-based working electrodes for electrochemiluminescence sensors.
Noman, Muhammad; Sanginario, Alessandro; Jagadale, Pravin; Demarchi, Danilo; Tagliaferro, Alberto
2017-06-01
In this work, unconventional carbon-based materials were investigated for use in electrochemiluminescence (ECL) working electrodes. Precursors such as bamboo, pistachio shells, kevlar ® fibers and camphor were differently treated and used as working electrodes in ECL experiments. After a proper process they were assembled as electrodes and tested in an electrochemical cell. Comparison among them and with a commercial glassy carbon electrode (GCE) shows a very good response for all of them thus demonstrating their potential use as disposable low-cost electrodes for early detection electrochemical analysis. Copyright © 2017 Elsevier B.V. All rights reserved.
Yang, Yukun; Fang, Guozhen; Wang, Xiaomin; Liu, Guiyang; Wang, Shuo
2016-03-15
A novel strategy is reported for the fabrication of bis-aniline-crosslinked Au nanoparticles (NPs)-CdSe/ZnS quantum dots (QDs) array composite by facil one-step co-electropolymerization of thioaniline-functionalized AuNPs and thioaniline-functionalized CdSe/ZnS QDs onto thioaniline-functionalized Au elctrodes (AuE). Stable and enhanced cathodic electrochemiluminescence (ECL) of CdSe/ZnS QDs is observed on the modified electrode in neutral solution, suggesting promising applications in ECL sensing. An advanced ECL sensor is explored for detection of 2-methyl-4-chlorophenoxyacetic acid (MCPA) which quenches the ECL signal through electron-transfer pathway. The sensitive determination of MCPA with limit of detection (LOD) of 2.2 nmolL(-1) (S/N=3) is achieved by π-donor-acceptor interactions between MCPA and the bis-aniline bridging units. Impressively, the imprinting of molecular recognition sites into the bis-aniline-crosslinked AuNPs-CdSe/ZnS QDs array yields a functionalized electrode with an extremely sensitive response to MCPA in a linear range of 10 pmolL(-1)-50 μmolL(-1) with a LOD of 4.3 pmolL(-1 ()S/N=3). The proposed ECL sensor with high sensitivity, good selectivity, reproducibility and stability has been successfully applied for the determination of MCPA in real samples with satisfactory recoveries. In this study, ECL sensor combined the merits of QDs-ECL and molecularly imprinting technology is reported for the first time. The developed ECL sensor holds great promise for the fabrication of QDs-based ECL sensors with improved sensitivity and furthermore opens the door to wide applications of QDs-based ECL in food safety and environmental monitoring. Copyright © 2015 Elsevier B.V. All rights reserved.
Schibilsky, David; Kruger, Tobias; Lausberg, Henning F; Eisenlohr, Christoph; Haller, Christoph; Nemeth, Attila; Schibilsky, Barbara; Haeberle, Helene; Rosenberger, Peter; Walker, Tobias; Schlensak, Christian
2016-09-01
The catheter-based Impella 5.0 left ventricular assist device is a powerful and less invasive alternative for patients in cardiogenic shock. The use as second-line therapy in patients with precedent extracorporeal life support (ECLS) has not been described before now. We analyzed our experience of consecutive patients treated with this alternative strategy. From April 2014 to December 2014, eight patients had been implanted as a second-line option after ECLS support. The reason for the change from ECLS to Impella 5.0 was absence of cardiac recovery for primary weaning and complications of ECLS therapy. The mean time of ECLS support prior to Impella implantation was 12 ± 7 days. The implantation of the Impella 5.0/CP was technically successful in all patients, and the ECLS could be explanted in all eight patients who received Impella implantation as a second-line treatment. The second-line Impella 5.0 therapy resulted in two patients who turned into left ventricular assist device (LVAD) candidates, two primary weaning candidates, and four patients who died in the setting of sepsis or absent cardiac recovery and contraindications for durable LVAD therapy. Thereby, the overall hospital discharge survival as well as the 180-day survival was 50% for Impella 5.0 implantations as second-line procedure after ECLS. The latest follow-up survival of this second-line strategy after ECLS was three out of eight, as one patient died after 299 days of LVAD support due to sepsis. The use of Impella 5.0 constitutes a possible second-line therapeutic option for those patients who do not show cardiac recovery during prolonged ECLS support or suffer from complications of ECLS therapy. This treatment allows additional time for decisions regarding cardiac recovery or indication for durable LVAD therapy. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Fouts, Alexandra; Miao, Dongmei; Zhao, Zhiyuan; Dong, Fran; Sosenko, Jay; Gottlieb, Peter; Rewers, Marian J.
2016-01-01
Abstract Background: Relatives with single positive islet autoantibodies have a much lower risk of progression to diabetes than those with multiple autoantibodies. Materials and Methods: TrialNet subjects positive for single autoantibody to insulin (mIAA) (n = 50) or single autoantibody to glutamic acid decarboxylase (GADA) (n = 50) were analyzed using new electrochemiluminescence (ECL) assays (ECL-IAA and ECL-GADA, respectively) at their initial visit and longitudinally over time. Affinity assays were performed on a subset of single autoantibody-positive subjects at initial and most recent visits. Results: After a mean follow-up of 5.3 years, 20 subjects developed type 1 diabetes. Among either single GADA or single mIAA subjects, those who were positive in the ECL assay showed higher affinity at the initial visit, and affinity results stayed consistent over time. No converting events from low to high or high to low affinity were seen over time. Conclusions: Confirmed positivity for ECL is associated with high affinity and can help staging of risk for type 1 diabetes in single autoantibody-positive subjects. PMID:26991969
ERIC Educational Resources Information Center
Tourangeau, Karen; Nord, Christine; Lê, Thanh; Wallner-Allen, Kathleen; Hagedorn, Mary C.; Leggitt, John; Najarian, Michelle
2015-01-01
This manual provides guidance and documentation for users of the longitudinal kindergarten-first grade (K-1) data file of the Early Childhood Longitudinal Study, Kindergarten Class of 2010-11 (ECLS-K:2011). It mainly provides information specific to the first-grade rounds of data collection. Data for the ECLS-K:2011 are released in both a…
2003-04-01
This photograph depicts one of over thirty tests conducted on the Vortex Combustion Chamber Engine at Marshall Space Flight Center's (MSFC) test stand 115, a joint effort between NASA's MSFC and the U.S. Army AMCOM of Redstone Arsenal. The engine tests were conducted to evaluate an irnovative, "self-cooled", vortex combustion chamber, which relies on tangentially injected propellants from the chamber wall producing centrifugal forces that keep the relatively cold liquid propellants near the wall.
Hoetzenecker, Konrad; Donahoe, Laura; Yeung, Jonathan C; Azad, Sassan; Fan, Eddy; Ferguson, Niall D; Del Sorbo, Lorenzo; de Perrot, Marc; Pierre, Andrew; Yasufuku, Kazuhiro; Singer, Lianne; Waddell, Thomas K; Keshavjee, Shaf; Cypel, Marcelo
2018-03-01
Extracorporeal life support (ECLS) is increasingly used to bridge deteriorating patients awaiting lung transplantation (LTx), however, few systematic descriptions of this practice exist. We therefore aimed to review our institutional experience over the past 10 years. In this case series, we included all adults who received ECLS with the intent to bridge to LTx. Data were retrieved from patient charts and our institutional ECLS and transplant databases. Between January 2006 and September 2016, 1111 LTx were performed in our institution. ECLS was used in 71 adults with the intention to bridge to LTx; of these, 11 (16%) were bridged to retransplantation. The median duration of ECLS before LTx was 10 days (range, 0-95). We used a single dual-lumen venous cannula in 23 patients (32%). Nine of 13 patients (69%) with pulmonary hypertension were bridged by central pulmonary artery to left atrium Novalung. Twenty-five patients (35%) were extubated while on ECLS and 26 patients (37%) were mobilized. Sixty-three patients (89%) survived to LTx. Survival by intention to treat was 66% (1 year), 58% (3 years) and 48% (5 years). Survival was significantly shorter in patients undergoing ECLS bridge to retransplantation compared with first LTx (median survival, 15 months (95% CI, 0-31) versus 60 months (95% CI, 37-83); P = .041). In our center experience, ECLS bridge to first lung transplant leads to good short-term and long-term outcomes in carefully selected patients. In contrast, our data suggest that ECLS as a bridge to retransplantation should be used with caution. Copyright © 2017 The American Association for Thoracic Surgery. All rights reserved.
Bist, Itti; Bhakta, Snehasis; Jiang, Di; Keyes, Tia E; Martin, Aaron; Forster, Robert J; Rusling, James F
2017-11-21
Damage to DNA from the metabolites of drugs and pollutants constitutes a major human toxicity pathway known as genotoxicity. Metabolites can react with metal ions and NADPH to oxidize DNA or participate in S N 2 reactions to form covalently linked adducts with DNA bases. Guanines are the main DNA oxidation sites, and 8-oxo-7,8-dihydro-2-deoxyguanosine (8-oxodG) is the initial product. Here we describe a novel electrochemiluminescent (ECL) microwell array that produces metabolites from test compounds and measures relative rates of DNA oxidation and DNA adduct damage. In this new array, films of DNA, metabolic enzymes, and an ECL metallopolymer or complex assembled in microwells on a pyrolytic graphite wafer are housed in dual microfluidic chambers. As reactant solution passes over the wells, metabolites form and can react with DNA in the films to form DNA adducts. These adducts are detected by ECL from a RuPVP polymer that uses DNA as a coreactant. Aryl amines also combine with Cu 2+ and NADPH to form reactive oxygen species (ROS) that oxidize DNA. The resulting 8-oxodG was detected selectively by ECL-generating bis(2,2'-bipyridine)-(4-(1,10-phenanthrolin-6-yl)-benzoic acid)Os(II). DNA/enzyme films on magnetic beads were oxidized similarly, and 8-oxodG determined by LC/MS/MS enabled array standardization. The array limit of detection for oxidation was 720 8-oxodG per 10 6 nucleobases. For a series of aryl amines, metabolite-generated DNA oxidation and adduct formation turnover rates from the array correlated very well with rodent 1/TD 50 and Comet assay results.
Maifeld, Sarah V; Ro, Bodrey; Mok, Hoyin; Chu, Marla; Yu, Li; Yamagata, Ryan; Leonardson, Tansy; Chio, Vera; Parhy, Bandita; Park, Samuel; Carlson, Marcia; Machhi, Shushil; Ulbrandt, Nancy; Falsey, Ann R; Walsh, Edward E; Wang, C Kathy; Esser, Mark T; Zuo, Fengrong
2016-01-01
Sensitive and precise serology assays are needed to measure the humoral response to antigens of respiratory syncytial virus (RSV) following natural infection or vaccination. We developed and evaluated a collection of electrochemiluminescent (ECL) serology assays using four RSV antigens (F, N, Ga and Gb). To assess the merits of ECL technology, the four ECL serology assays were evaluated using a well-characterized "gold standard" panel of acute and convalescent serum samples from fifty-nine RSV-positive and thirty RSV-negative elderly subjects (≥65 years old). The combined results from the four ECL assays demonstrated good concordance to the "gold standard" diagnosis, reaching 95% diagnostic sensitivity and 100% diagnostic specificity. Additionally, a combination of ECL assays provided higher diagnostic sensitivity than a commercially available diagnostic ELISA or cell-based microneutralization assay. In summary, these data demonstrate the advantages of using ECL-based serology assays and highlight their use as a sensitive diagnostic approach to detect recent RSV infection in an elderly population.
Liu, Jia-Li; Zhao, Min; Zhuo, Ying; Chai, Ya-Qin; Yuan, Ruo
2017-02-03
The intermolecular electrochemiluminescence resonance energy transfer (ECL-RET) between luminol and Ru(bpy) 3 2+ was studied extensively to achieve the sensitive bioanalysis owing to the perfect spectral overlap of the donor and acceptor, but it still suffers from the challenging issue of low energy-transfer efficiency. The intramolecular ECL-RET towards the novel ECL compound containing the donor of luminol and the acceptor of Ru(bpy) 2 (mcpbpy) 2+ (Lum-Ru) was designed and investigated. With the high-efficient ECL-RET in one molecule, the highly intense ECL signal of Lum-Ru was obtained owing to the short path of energy transmission and less energy loss between luminol and Ru(bpy) 2 (mcpbpy) 2+ . Lum-Ru was further applied to construct a signal-off electrochemiluminescence (ECL) aptasensor for ultrasensitive detection of a harsh carcinogen of Aflatoxin M1 (AFM1). This sensing platform also provides a significant boost for the trace detection of other biomolecules in clinical analysis. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
1976-10-02
On October 02, 1976, Marshall Space Flight Center’s (MSFC) Redstone test stand was received into the National Registry of Historical Places. Photographed in front of the Redstone test stand are Dr. William R. Lucas, MSFC Center Director from June 15, 1974 until July 3, 1986, as he is accepting a certificate of registration from Madison County Commission Chairman James Record, and Huntsville architect Harvie Jones.
NASA Technical Reports Server (NTRS)
Hadaway, James B.; Connatser, Robert; Cothren, Bobby; Johnson, R. B.
1993-01-01
Work performed by the University of Alabama in Huntsville's (UAH) Center for Applied Optics (CAO) entitled Atomic Research is documented. Atomic oxygen (AO) effects on materials have long been a critical concern in designing spacecraft to withstand exposure to the Low Earth Orbit (LEO) environment. The objective of this research effort was to provide technical expertise in the design of instrumentation and experimental techniques for analyzing materials exposed to atomic oxygen in accelerated testing at NASA/MSFC. Such testing was required to answer fundamental questions concerning Space Station Freedom (SSF) candidate materials and materials exposed to atomic oxygen aboard the Long-Duration Exposure Facility (LDEF). The primary UAH task was to provide technical design, review, and analysis to MSFC in the development of a state-of-the-art 5eV atomic oxygen beam facility required to simulate the RAM-induced low earth orbit (LEO) AO environment. This development was to be accomplished primarily at NASA/MSFC. In support of this task, contamination effects and ultraviolet (UV) simulation testing was also to be carried out using NASA/MSFC facilities. Any materials analysis of LDEF samples was to be accomplished at UAH.
Multi Purpose Crew Vehicle Environmental Control and Life Support Development Status
NASA Technical Reports Server (NTRS)
Lewis, John F.; Barido, Richard A.; Cross, Cynthia D.; Rains, George Edward
2012-01-01
The Orion Multi Purpose Crew Vehicle (MPCV) is the first crew transport vehicle to be developed by the National Aeronautics and Space Administration (NASA) in the last thirty years. Orion is currently being developed to transport the crew safely beyond Earth orbit. This year, the vehicle focused on building the Exploration Flight Test 1 (EFT1) vehicle to be launched in 2014. The development of the Orion Environmental Control and Life Support (ECLS) System, focused on the completing the components which are on EFT1. Additional development work has been done to keep the remaining component progressing towards implementation for a flight tests in of EM1 in 2017 and in and EM2 in 2020. This paper covers the Orion ECLS development from April 2012 to April 2013.
MSFC Optical Metrology: A National Resource
NASA Technical Reports Server (NTRS)
Burdine, Robert
1998-01-01
A national need exists for Large Diameter Optical Metrology Services. These services include the manufacture, testing, and assurance of precision and control necessary to assure the success of large optical projects. "Best Practices" are often relied on for manufacture and quality controls while optical projects are increasingly more demanding and complex. Marshall Space Flight Center (MSFC) has acquired unique optical measurement, testing and metrology capabilities through active participation in a wide variety of NASA optical programs. An overview of existing optical facilities and metrology capabilities is given with emphasis on use by other optical projects. Cost avoidance and project success is stressed through use of existing MSFC facilities and capabilities for measurement and metrology controls. Current issues in large diameter optical metrology are briefly reviewed. The need for a consistent and long duration Large Diameter Optical Metrology Service Group is presented with emphasis on the establishment of a National Large Diameter Optical Standards Laboratory. Proposals are made to develop MSFC optical standards and metrology capabilities as the primary national standards resource, providing access to MSFC Optical Core Competencies for manufacturers and researchers. Plans are presented for the development of a national lending library of precision optical standards with emphasis on cost avoidance while improving measurement assurance.
Conceptions of Early Childhood Leadership: Driving New Professionalism?
ERIC Educational Resources Information Center
Sims, Margaret; Forrest, Rhonda; Semann, Anthony; Slattery, Colin
2015-01-01
This study reports the understandings of leadership held by 351 Victorian early childhood leaders (ECLs). Internationally, ECLs are expected to drive quality improvement through mentoring and modelling: a concept associated with distributive leadership. However, ECLs often move into leadership positions by accident and are ill-prepared for their…
Bektaş, Mehmet; Saraç, Nurşen; Cetinkaya, Hülya; Törüner, Murat; Erdemli, Esra; Keskin, Onur; Soykan, Irfan; Oktay, Esen Ismet; Korkut, Esin; Ustün, Yusuf; Bahar, Kadir
2012-01-01
Excessive release of gastrin leads to hypertrophy and hyperplasia of enterochromaffin-like cells (ECL) and prolonged stimulation of these cells causes functional impairment. The purpose of this study was to investigate the effect of Helicobacter pylori ( H. pylori) infection and long-term proton pump inhibitors (PPI) use on ECL cells. Fifteen patients who underwent endoscopy because of dyspeptic symptoms were enrolled in the present study. Biopsies were taken from corpus and antrum and existence of H. pylori was investigated with culture, cytology and CLOtest. The patients were divided into 3 groups. Group-A: H. pylori -negative, never treated previously with PPI; Group-B: H. pylori -positive, never treated previously with PPI; and group-C: H. pylori -negative and continuously treated with PPI for more than 6 months before the subject recruitment period. The features of ECL cell in oxyntic glands were examined with electron microscopy on biopsy specimens. ECL cells were completely normal in Group A. In group B, moderate hyperplasia and vacuolization was seen in ECL cells. In group C, ECL cell hyperplasia was observed and vacuoles with greater amounts of granules in enlarged vesicles were found more intensely in cytoplasm. The use of PPI for a long period of time and presence of H. pylori infection are risk factors for ECL hyperplasia.
Zhang, Meihe; Yuan, Ruo; Chai, Yaqin; Chen, Shihong; Zhong, Huaan; Wang, Cun; Cheng, Yinfeng
2012-02-15
A novel cholesterol biosensor was prepared based on gold nanoparticles-catalyzed luminol electrogenerated chemiluminescence (ECL). Firstly, l-cysteine-reduced graphene oxide composites were modified on the surface of a glassy carbon electrode. Then, gold nanoparticles (AuNPs) were self-assembled on it. Subsequently, cholesterol oxidase (ChOx) was adsorbed on the surface of AuNPs to construct a cholesterol biosensor. The stepwise fabrication processes were characterized with cyclic voltammetry and atomic force microscopy. The ECL behaviors of the biosensor were also investigated. It was found that AuNPs not only provided larger surface area for higher ChOx loading but also formed the nano-structured interface on the electrode surface to improve the analytical performance of the ECL biosensor for cholesterol. Besides, based on the efficient catalytic ability of AuNPs to luminol ECL, the response of the biosensor to cholesterol was linear range from 3.3 μM to 1.0 mM with a detection limit of 1.1 μM (S/N=3). In addition, the prepared ECL biosensor exhibited satisfying reproducibility, stability and selectivity. Taking into account the advantages of ECL, we confidently expect that ECL would have potential applications in biotechnology and clinical diagnosis. Copyright © 2011 Elsevier B.V. All rights reserved.
Mao, Li; Yuan, Ruo; Chai, Yaqin; Zhuo, Ying; Xiang, Yun
2011-06-15
An innovatory ECL immunoassay strategy was proposed to detect the newly developing heart failure biomarker N-terminal pro-brain natriuretic peptide (NT-proBNP). Firstly, this strategy used small molecules encapsulated liposome as immune label to construct a sandwich immune sensing platform for NT-proBNP. Then the ECL aptasensor was prepared to collect and detect the small molecules released from the liposome. Finally, based on the ECL signal changes caused by the small molecules, the ECL signal indirectly reflected the level of NT-proBNP antigen. In this experiment, the cocaine was chosen as the proper small molecule that can act as signal-enhancer to enhance the ECL of Ru(bpy)(3)(2+). The cocaine-encapsulated liposomes were successfully characterized by TEM. The quantificational calculation proved the ∼5.3×10(3) cocaine molecules per liposome enough to perform the assignment of signal amplification. The cocaine-binding ECL aptasensor further promoted the work aimed at amplifying signal. The performance of NT-proBNP assay by the proposed strategy exhibited high sensitivity and high specificities with a linear relationship over 0.01-500 ng mL(-1) range, and a detection limit down to 0.77 pg mL(-1). Copyright © 2011 Elsevier B.V. All rights reserved.
Roy, Sharmili; Wei, Sim Xiao; Ying, Jean Liew Zhi; Safavieh, Mohammadali; Ahmed, Minhaz Uddin
2016-12-15
Electrochemiluminescence (ECL) has been widely rendered for nucleic acid testing. Here, we integrate loop-mediated isothermal amplification (LAMP) with ECL technique for DNA detection and quantification. The target LAMP DNA bound electrostatically with [Ru(bpy)3](+2) on the carbon electrode surface, and an ECL reaction was triggered by tripropylamine (TPrA) to yield luminescence. We illustrated this method as a new and highly sensitive strategy for the detection of sequence-specific DNA from different meat species at picogram levels. The proposed strategy renders the signal amplification capacities of TPrA and combines LAMP with inherently high sensitivity of the ECL technique, to facilitate the detection of low quantities of DNA. By leveraging this technique, target DNA of Sus scrofa (pork) meat was detected as low as 1pg/µL (3.43×10(-1)copies/µL). In addition, the proposed technique was applied for detection of Bacillus subtilis DNA samples and detection limit of 10pg/µL (2.2×10(3)copies/µL) was achieved. The advantages of being isothermal, sensitive and robust with ability for multiplex detection of bio-analytes makes this method a facile and appealing sensing modality in hand-held devices to be used at the point-of-care (POC). Copyright © 2016 Elsevier B.V. All rights reserved.
1997-06-04
A close-up view of Bantam duration testing of the 40K Fastrac II Engine for X-34 at Marshall Space Flight Center's (MSFC) test stand 116. The Bantam test refers to the super lightweight engines of the Fastrac program. The engines were designed as part of the low cost X-34 Reusable Launch Vehicle (RLV). The testing of these engines at MSFC allowed the engineers to determine the capabilities of these engines and the metal alloys that were used in their construction. The Fastrac and X-34 programs were cancelled in 2001.
Description of MSFC engineering photographic analysis
NASA Technical Reports Server (NTRS)
Earle, Jim; Williams, Frank
1988-01-01
Utilizing a background that includes development of basic launch and test photographic coverage and analysis procedures, the MSFC Photographic Evaluation Group has built a body of experience that enables it to effectively satisfy MSFC's engineering photographic analysis needs. Combining the basic soundness of reliable, proven techniques of the past with the newer technical advances of computers and computer-related devices, the MSFC Photo Evaluation Group is in a position to continue to provide photo and video analysis service center-wide and NASA-wide to supply an improving photo analysis product to meet the photo evaluation needs of the future; and to provide new standards in the state-of-the-art of photo analysis of dynamic events.
International Space Station (ISS) Low Pressure Intramodule Quick Disconnect Failures
NASA Technical Reports Server (NTRS)
Lewis, John F.; Harris, Danny; Link, Dwight; Morrison, Russel
2004-01-01
A failure of an ISS intermodule Quick Disconnect (QD) during protoflight vibration testing of ISS regenerative Environmental Control and Life Support (ECLS) hardware led to the discovery of QD design, manufacturing, and test flaws which can yield the male QD susceptible to failure of the secondary housing seal and inadequate housing assembly locking mechanisms. Discovery of this failure had large implications when considering that currently there are 399 similar units on orbit and approximately 1100 units on the ground integrated into flight hardware. Discovery of the nature of the failure required testing and analysis and implementation of a recovery plan requiring part screening and review of element level and project hazard analysis to determine if secondary seals are required. Implementation also involves coordination with the Nodes and MPLM project offices, Regenerative ECLS Project, ISS Payloads, JAXA, ESA, and ISS Logistics and Maintenance.
International Space Station ECLSS Technical Task Agreement Summary Report
NASA Technical Reports Server (NTRS)
Minton-Summers, S.; Ray, C. D.
1996-01-01
A summary of work accomplished under Technical Task Agreement by the Marshall Space Flight Center (MSFC) documents activities regarding the Environmental Control and Life Support Systems (ECLSS) of the International Space Station (ISS) program. These MSFC activities were in-line to the designing, the development, the testing, and the flight of ECLSS equipment. MSFC's unique capabilities for performing integrated system testing and analyses, and its ability to perform some tasks cheaper and faster to support ISS program needs are the basis for the Technical Task Agreement activities. Tasks were completed in the Water Recovery Systems, Air Revitalization Systems, and microbiology areas. The results of each task is described in this summary report.
1967-01-01
NASA used barges for transporting full-sized stages for the Saturn I, Saturn IB, and Saturn V vehicles between the Marshall Space Flight Center (MSFC), the manufacturing plant at the Michoud Assembly Facility (MAF), the Mississippi Test Facility for testing, and the Kennedy Space Center. The barges traveled from the MSFC dock to the MAF, a total of 1,086.7 miles up the Tennessee River and down the Mississippi River. The barges also transported the assembled stages of the Saturn vehicle from the MAF to the Kennedy Space Center, a total of 932.4 miles along the Gulf of Mexico and up along the Atlantic Ocean, for the final assembly and the launch. This photograph shows the barge Orion at the MSFC dock.
Guan, Xiaolu; Zhang, Yao; Yu, Mengmeng; Ren, Chaoqi; Gao, Yanni; Yun, Bingling; Liu, Yongzhen; Wang, Yongqiang; Qi, Xiaole; Liu, Changjun; Cui, Hongyu; Zhang, Yanping; Gao, Li; Li, Kai; Pan, Qing; Zhang, Baoshan; Wang, Xiaomei; Gao, Yulong
2018-01-01
Chicken Na + /H + exchanger type I (chNHE1), a multispan transmembrane protein, is a cellular receptor of the subgroup J avian leukosis virus (ALV-J). To identify the functional determinants of chNHE1 responsible for the ALV-J receptor activity, a series of chimeric receptors was created by exchanging the extracellular loops (ECL) of human NHE1 (huNHE1) and chNHE1 and by ECL replacement with a hemagglutinin (HA) tag. These chimeric receptors then were used in binding and entry assays to map the minimal ALV-J gp85-binding domain of chNHE1. We show that ECL1 of chNHE1 (chECL1) is the critical functional ECL that interacts directly with ALV-J gp85; ECL3 is also involved in ALV-J gp85 binding. Amino acid residues 28 to 39 of the N-terminal membrane-proximal region of chECL1 constitute the minimal domain required for chNHE1 binding of ALV-J gp85. These residues are sufficient to mediate viral entry into ALV-J nonpermissive cells. Point mutation analysis revealed that A30, V33, W38, and E39 of chECL1 are the key residues mediating the binding between chNHE1 and ALV-J gp85. Further, the replacement of residues 28 to 39 of huNHE1 with the corresponding chNHE1 residues converted the nonfunctional ALV-J receptor huNHE1 to a functional one. Importantly, soluble chECL1 and huECL1 harboring chNHE1 residues 28 to 39 both could effectively block ALV-J infection. Collectively, our findings indicate that residues 28 to 39 of chNHE1 constitute a domain that is critical for receptor function and mediate ALV-J entry. IMPORTANCE chNHE1 is a cellular receptor of ALV-J, a retrovirus that causes infections in chickens and serious economic losses in the poultry industry. Until now, the domains determining the chNHE1 receptor function remained unknown. We demonstrate that chECL1 is critical for receptor function, with residues 28 to 39 constituting the minimal functional domain responsible for chNHE1 binding of ALV-J gp85 and efficiently mediating ALV-J cell entry. These residues are located in the membrane-proximal region of the N terminus of chECL1, suggesting that the binding site of ALV-J gp85 on chNHE1 is probably located on the apex of the molecule; the receptor-binding mode might be different from that of retroviruses. We also found that soluble chECL1, as well as huECL1 harboring chNHE1 residues 28 to 39, effectively blocked ALV-J infection. These findings contribute to a better understanding of the ALV-J infection mechanism and also provide new insights into the control strategies for ALV-J infection. Copyright © 2017 American Society for Microbiology.
Assessment Issues in the Testing of Children at School Entry
ERIC Educational Resources Information Center
Rock, Donald A.; Stenner, A. Jackson
2005-01-01
The authors introduce readers to the research documenting racial and ethnic gaps in school readiness. They describe the key tests, including the Peabody Picture Vocabulary Test (PPVT), the Early Childhood Longitudinal Study (ECLS), and several intelligence tests, and describe how they have been administered to several important national samples of…
COI Structural Analysis Presentation
NASA Technical Reports Server (NTRS)
Cline, Todd; Stahl, H. Philip (Technical Monitor)
2001-01-01
This report discusses the structural analysis of the Next Generation Space Telescope Mirror System Demonstrator (NMSD) developed by Composite Optics Incorporated (COI) in support of the Next Generation Space Telescope (NGST) project. The mirror was submitted to Marshall Space Flight Center (MSFC) for cryogenic testing and evaluation. Once at MSFC, the mirror was lowered to approximately 40 K and the optical surface distortions were measured. Alongside this experiment, an analytical model was developed and used to compare to the test results. A NASTRAN finite element model was provided by COI and a thermal model was developed from it. Using the thermal model, steady state nodal temperatures were calculated based on the predicted environment of the large cryogenic test chamber at MSFC. This temperature distribution was applied in the structural analysis to solve for the deflections of the optical surface. Finally, these deflections were submitted for optical analysis and comparison to the interferometer test data.
Gas Emission Measurements from the RD 180 Rocket Engine
NASA Technical Reports Server (NTRS)
Ross, H. R.
2001-01-01
The Science Laboratory operated by GB Tech was tasked by the Environmental Office at the NASA Marshall Space Flight Center (MSFC) to collect rocket plume samples and to measure gaseous components and airborne particulates from the hot test firings of the Atlas III/RD 180 test article at MSFC. This data will be used to validate plume prediction codes and to assess environmental air quality issues.
Advanced Space Transportation Program (ASTP)
1997-08-07
This double exposure depicts Marshall Space Flight Center's (MSFC) Test Stand 116 hosting a 60K Bantam Fastrac thrust chamber assembly test. The lower right exposure shows the engine firing in the test stand while the center exposure reveals workers monitoring the test in the interior block house of the test facility. The thrust chamber assembly is only part of the Fastrac engine project to build a low-cost engine for the X-34, an alternate light-weight unmarned launch vehicle. Both the nozzle and the engine for Fastrac are being manufactured at MSFC.
Enriching a Child's Literacy Environment (ECLE).
ERIC Educational Resources Information Center
Reid, Ethna R.
The Enriching a Child's Literacy Environment (ECLE) program was designed to establish a model for teaching parents, teachers, and other care providers how to develop the oral language, thinking abilities and motor skills of young children (ages six months to three years). ECLE trainers instruct the parents or other care providers by first modeling…
Wang, Jingwu; Yang, Zhiming; Wang, Xiaoxia; Yang, Nianjun
2008-06-30
Tris(2,2'-bipyridyl) ruthenium(II) (Ru(bpy)(3)(2+))-roxithromycin based electrochemiluminescence (ECL) was enhanced greatly by gold nanoparticles 10 nm in diameter. Capillary electrophoresis (CE) was coupled with the resultant ECL system as a detector for roxithromycin. This ECL emission is explained by the coreactant mechanism where roxithromycin behaves as a coreactant to generate strong reducing species and gold nanoparticles act as "floating nanoelectrodes". The reaction of Ru(bpy)(3)(3+) with the generated strong reducing species on the Pt working electrode as well as on "floating nanoelectrodes" releases Ru(bpy)(3)(2+*), resulting in enhancement of ECL emission. The selectivity of this detection system towards roxithromycin was examined by CE. Under the optimized conditions, the intensity of ECL emission varies linearly with the concentration of roxithromycin from 24 nM to 0.24 mM. The detection limit is 8.4 nM, while without adding gold nanoparticles it is only 84 nM. The detection of roxithromycin in pharmaceutical and urine samples was also performed by the proposed CE-ECL method.
Shin, Sangbaie; Park, Yun Sung; Cho, Sunghwan; You, Insang; Kang, In Seok
2018-01-01
Electro-generated chemiluminescence (ECL) has attracted increasing attention as a new platform for light-emitting devices; in particular, the use of mechanically stretchable ECL gels opens up the opportunity to achieve deformable displays. The movements of radical ions under an external electric field include short-range diffusion near the electrodes and long-distance migration between the electrodes. So far, only the diffusion of radical ions has been considered as the operating principle behind ECL. In this study, electrochemical and optical analysis was performed systematically to investigate the role of ion migration in ECL devices. This study reveals that long-distance migration of radical ions can be a key variable in ECL at low frequencies and that this effect depends on the type of ion species and the operating conditions (e.g. voltage and frequency). We also report that the emissions from the two electrodes are not identical, and the emission behaviors are different in the optimal operating conditions for the red, green, and blue ECL emissions. PMID:29732124
Redstone Test Stand Accepted Into National Register of Historical Places
NASA Technical Reports Server (NTRS)
1976-01-01
On October 02, 1976, Marshall Space Flight Center's (MSFC) Redstone test stand was received into the National Registry of Historical Places. Photographed in front of the Redstone test stand along with their wives are (left to right), Madison County Commission Chairman James Record, Dr. William R. Lucas, MSFC Center Director from June 15, 1974 until July 3, 1986, (holding certificate), Ed, Buckbee, Space and Rocket Center Director; Harvie Jones, Huntsville Architect; Dick Smith; and Joe Jones.
The Marshall Space Flight Center KC-135 zero gravity test program for FY 1982
NASA Technical Reports Server (NTRS)
Shurney, R. E. (Editor)
1983-01-01
During FY-82, researchers and experimenters from Marshall Space Flight Center (MSFC) conducted 11 separate investigations during 26.3 hr of testing aboard the KC-135 zero-gravity aircraft, based at Ellington Air force Base, Texas. Although this represented fewer hours than initially projected, all experiment and test objectives were met or exceeded. This Technical Memorandum compiles all results achieved by MSFC users during FY-82, a year considered to be highly productive.
ECLS systems for a lunar base - A baseline and some alternate concepts
NASA Technical Reports Server (NTRS)
Hypes, Warren D.; Hall, John B., Jr.
1988-01-01
A baseline ECLS system for a lunar base manned intermittently by four crewmembers and later permanently occupied by eight crewmembers has been designed. A summary of the physical characteristics for the intermittently manned and the continuously manned bases is given. Since Space Station inheritance is a key assumption in the mission models, the ECLS system components are distributed within Space Station modules and nodes. A 'core assembly' concept is then developed to meet the objectives of both phases of the ECLS system. A supplementary study is discussed which assessed tankage requirements, penalties incurred by adding subsystem redundancy and by pressurizing large surface structures, and difficulties imposed by intermittent occupancy. Alternate concepts using lunar-derived oxygen, the gravitational field as a design aid, and a city utility-type ECLS system are also discussed.
NASA Astrophysics Data System (ADS)
Permana, I.; Redjeki, S.; Hamidah, I.; Safitri, N.
2017-09-01
This study reported the student’s Extraneous Cognitive Load (ECL) in the Pedagogical Content and Knowledge of solar system Course. Participants in the study were 31 pre-service elementary school teachers from the university in Bogor Indonesia. The data collected from ECL were obtained using a Likert 4-scale questionnaire and interview. After taking lectures, we asked for some mental effort from pre-service elementary school teachers to attend courses in order to assess the ECL. The courses include 3 topics and they were non-experimental worksheet, developing experimental worksheet using Vee Diagram framework, and analysis for curriculum by grade IV, V and VI. Results of the data analysis showed that the course strategy resulted by ECL was relatively low. The ECL increased in the course of curriculum analysis due to material complexity.
Pozzi, Matteo; Koffel, Catherine; Djaref, Camelia; Grinberg, Daniel; Fellahi, Jean Luc; Hugon-Vallet, Elisabeth; Prieur, Cyril; Robin, Jacques; Obadia, Jean François
2017-07-01
Cardiac failure is still a leading cause of death in drug intoxication. Extracorporeal life support (ECLS) could be used as a rescue therapeutic option in patients developing refractory cardiogenic shock or cardiac arrest. The aim of this report is to present our results of ECLS in the setting of poisoning from cardiotoxic drugs. We included in this analysis consecutive patients who received an ECLS for refractory cardiogenic shock or in-hospital cardiac arrest due to drug intoxication. The primary endpoint of our study was survival to hospital discharge with good neurological recovery after ECLS support. Between January 2010 and December 2015, we performed 12 ECLS. Mean age was 44.2±17.8 years and there was a predominance of females (66.7%). Drug intoxication was mainly due to beta-blockers and/or calcium channel inhibitors (83.3%) and 5 (41.7%) patients had multiple drugs overdose. Weaning rate and survival to hospital discharge with good neurological recovery were 75% (9 patients). Among patients weaned from ECLS, mean duration of support was 2.4±1.1 days. Three (25%) patients underwent ECLS implantation during cardiopulmonary resuscitation, 2 (66.6%) of them died while on mechanical circulatory support (MCS). Six (50%) patients developed lower limb ischemia. Each patient was managed with ECLS decannulation: 2 (16.7%) patients underwent a concomitant iliofemoral thrombectomy, 3 (25%) needed further fasciotomy and the remaining patient (8.3%) required an amputation. Refractory cardiogenic shock due to drug intoxication is still one of the best indications for ECLS owing to the satisfactory survival with good neurological outcome in such a critically ill population. Further data are however necessary in order to best understand the possible relation between drug intoxication and lower limb ischemia, which was quite superior to the reported rates.
Fabrication and Testing of Low Cost 2D Carbon-Carbon Nozzle Extensions at NASA/MSFC
NASA Technical Reports Server (NTRS)
Greene, Sandra Elam; Shigley, John K.; George, Russ; Roberts, Robert
2015-01-01
Subscale liquid engine tests were conducted at NASA/MSFC using a 1.2 Klbf engine with liquid oxygen (LOX) and gaseous hydrogen. Testing was performed for main-stage durations ranging from 10 to 160 seconds at a chamber pressure of 550 psia and a mixture ratio of 5.7. Operating the engine in this manner demonstrated a new and affordable test capability for evaluating subscale nozzles by exposing them to long duration tests. A series of 2D C-C nozzle extensions were manufactured, oxidation protection applied and then tested on a liquid engine test facility at NASA/MSFC. The C-C nozzle extensions had oxidation protection applied using three very distinct methods with a wide range of costs and process times: SiC via Polymer Impregnation & Pyrolysis (PIP), Air Plasma Spray (APS) and Melt Infiltration. The tested extensions were about 6" long with an exit plane ID of about 6.6". The test results, material properties and performance of the 2D C-C extensions and attachment features will be discussed.
Development and Testing of a Novel Green Propellant Piston Tank
NASA Technical Reports Server (NTRS)
Diaz, C. E.; Cavender, D. P.; Higdon, K.; Abrams, J.; Duchek, M. E.; Mader, H.
2017-01-01
Analytical Mechanics Associates (AMA), in cooperation with NASA Marshall Space Flight Center's (MSFC's) Spacecraft Propulsion Systems Branch, developed and tested a novel propellant tank design that employs an internal piston pressurized with an inert gas to expel propellant to thrusters. During the course of this activity, AMA designed, oversaw fabrication, and delivered to MSFC for testing, a piston propellant tank sized for 3U or larger CubeSats. MSFC conducted liquid expulsion testing using ethylene glycol as a referee fluid to map the tank's performance at different pressures and piston positions. Following the expulsion test campaign, the tank is planned to be integrated into a propulsion system test bed for hot fire tests with a 100mN monopropellant thruster to evaluate the tank's influence on thruster performance when operated in a flight like manner. Described in this paper is a comprehensive summary of how the tanks were designed, built, and tested. The fundamental knowledge gained through the fabrication and testing of these tanks gives evidence that the piston tank design may be scalable to meet the requirements and constraints of other small satellites.
Bektaş, Mehmet; Saraç, Nurşen; Çetinkaya, Hülya; Törüner, Murat; Erdemli, Esra; Keskin, Onur; Soykan, İrfan; Oktay, Esen Ismet; Korkut, Esin; Üstün, Yusuf; Bahar, Kadir
2012-01-01
Background Excessive release of gastrin leads to hypertrophy and hyperplasia of enterochromaffin-like cells (ECL) and prolonged stimulation of these cells causes functional impairment. The purpose of this study was to investigate the effect of Helicobacter pylori (H. pylori) infection and long-term proton pump inhibitors (PPI) use on ECL cells. Methods Fifteen patients who underwent endoscopy because of dyspeptic symptoms were enrolled in the present study. Biopsies were taken from corpus and antrum and existence of H. pylori was investigated with culture, cytology and CLOtest. The patients were divided into 3 groups. Group-A: H. pylori-negative, never treated previously with PPI; Group-B: H. pylori-positive, never treated previously with PPI; and group-C: H. pylori-negative and continuously treated with PPI for more than 6 months before the subject recruitment period. The features of ECL cell in oxyntic glands were examined with electron microscopy on biopsy specimens. Results ECL cells were completely normal in Group A. In group B, moderate hyperplasia and vacuolization was seen in ECL cells. In group C, ECL cell hyperplasia was observed and vacuoles with greater amounts of granules in enlarged vesicles were found more intensely in cytoplasm. Conclusion The use of PPI for a long period of time and presence of H. pylori infection are risk factors for ECL hyperplasia. PMID:24714139
DNA tetrahedral scaffolds-based platform for the construction of electrochemiluminescence biosensor.
Feng, Qiu-Mei; Zhou, Zhen; Li, Mei-Xing; Zhao, Wei; Xu, Jing-Juan; Chen, Hong-Yuan
2017-04-15
Proximal metallic nanoparticles (NPs) could quench the electrochemiluminescence (ECL) emission of semiconductor quantum dots (QDs) due to Förster energy transfer (FRET), but at a certain distance, the coupling of light-emission with surface plasmon resonance (SPR) result in enhanced ECL. Thus, the modification strategies and distances control between QDs and metallic NPs are critical for the ECL intensity of QDs. In this strategy, a SPR enhanced ECL sensor based on DNA tetrahedral scaffolds modified platform was reported for the detection of telomerase activity. Due to the rigid three-dimensional structure, DNA tetrahedral scaffolds grafting on the electrode surface could accurately modulate the distance between CdS QDs and luminol labelled gold nanoparticles (L-Au NPs), meanwhile provide an enhanced spatial dimension and accessibility for the assembly of multiple L-Au NPs. The ECL intensities of both CdS QDs (-1.25V vs. SCE) and luminol (+0.33V vs. SCE) gradually increased along with the formation of multiple L-Au NPs at the vertex of DNA tetrahedral scaffolds induced by telomerase, bringing in a dual-potential ECL analysis. The proposed method showed high sensitivity for the identification of telomerase and was successfully applied for the differentiation of cancer cells from normal cells. This work suggests that DNA tetrahedral scaffolds could serve as an excellent choice for the construction of SPR-ECL system. Copyright © 2016 Elsevier B.V. All rights reserved.
1971-06-01
The Apollo Telescope Mount (ATM) was one of four major components of Skylab that were designed and constructed under the management of the Marshall Space Flight Center (MSFC). In this photograph, an ATM is seen sitting inside the MSFC's Structural Load Test Arnex where the main structural elements were simulated under launch conditions.
Development of Mirror Modules for the ART-XC Instrument aboard the Spectrum-Roentgen-Gamma Mission
NASA Technical Reports Server (NTRS)
Gubarev, M.; Ramsey, B.; O'Dell, S. L.; Elsner, R.; Kilaru, K.; McCracken, J.; Atkins, C.; Pavlinsky, M.; Tkachenko, A.; Lapshov, I.
2013-01-01
MSFC is developing eight x-ray mirror modules for the ART-XC instrument on board the SRG Mission. The Engineering Unit tests are successful. MSFC is on schedule to deliver flight units in the November of 2013 and January 2014.
1976-10-02
On October 02, 1976, Marshall Space Flight Center’s (MSFC) Redstone test stand was received into the National Registry of Historical Places. Photographed in front of the Redstone test stand along with their wives are (left to right), Madison County Commission Chairman James Record, Dr. William R. Lucas, MSFC Center Director from June 15, 1974 until July 3, 1986, (holding certificate), Ed, Buckbee, Space and Rocket Center Director; Harvie Jones, Huntsville Architect; Dick Smith; and Joe Jones.
Chang-Lin, Joan-En; Kim, Kwang-Jin; Lee, Vincent H L
2005-06-01
Previously, we reported the development of a primary culture model of tight rabbit corneal epithelial cell layers (RCrECL) characterizing bioelectric parameters, morphology, cytokeratin, and passive permeability. In the present study, we specifically evaluated the active ion transport processes of RCrECL cultured from either pigmented or albino rabbits. Primary cultured RCrECL were grown at an air-interface on Clear-Snapwells precoated with collagen/fibronectin/laminin and mounted in a modified Ussing-type chamber for the evaluation of their active ion transport processes under short-circuited conditions. Contribution of active Na(+) and Cl(-) transport to overall short-circuit current (I(sc)) was evaluated by removing Na(+) and Cl(-), respectively, from bathing fluids of RCrECL and measurements of net fluxes of Na(+) and Cl(-) using (22)Na and (36)Cl, respectively. Amiloride and benzamil were used to determine the role of apical Na(+)-channel activities to net Na(+) fluxes. N-phenylanthranilic acid (NPAA), ouabain, BaCl(2) and bumetanide were used to determine the role of basolateral Na,K-ATPase, apical Cl(-)-channel, and basolateral K(+)-channel and Na(+)(K(+))2Cl(-)-cotransporter activities, respectively, in active ion transport across RCrECL. I(sc) of RCrECL derived from pigmented rabbits was comprised of 64+/-2% and 44+/-5% for active Na(+) and Cl(-) transport, respectively, consistent with net Na(+) absorption and Cl(-) secretion of 0.062+/-0.006 and 0.046+/-0.008 muEq/cm(2)/hr estimated from radionuclide fluxes. Apical amiloride and benzamil inhibited I(sc) by up to approximately 50% with an IC(50) of 1 and 0.1 microm, respectively, consistent with participation of apical epithelial Na(+)-channels to net Na(+) absorption across RCrECL cultured from pigmented rabbits. Addition of ouabain to the basolateral, NPAA to the apical, BaCl(2) to the basolateral and bumetanide to basolateral fluid decreased I(sc) by 86+/-1.5%, 53+/-3%, 18+/-1.8% and 13+/-1.9% in RCrECL cultured from pigmented rabbits, while 85+/-0.7%, 36+/-1.6%, 38+/-1.8% and 15+/-3.5% decreases are observed for RCrECL from albino rabbits, respectively. Air-interface cultured RCrECL from either pigmented or albino rabbits exhibited active ion transport properties similar to those present in excised tissues. This primary culture system may be a reliable in-vitro model for mechanistic characterization of corneal epithelial function and regulation of transport properties.
Shan, Yun; Xu, Jing-Juan; Chen, Hong-Yuan
2011-07-01
This work reports an aptasensor for ultrasensitive detection of thrombin based on remarkably efficient energy-transfer induced electrochemiluminescence (ECL) quenching from CdS:Mn nanocrystals (NCs) film to CdTe QDs-doped silica nanoparticles (CdTe/SiO(2) NPs). CdTe/SiO(2) NPs were synthesized via the Stöber method and showed black bodies' strong absorption in a wide spectral range without excitonic emission, which made them excellent ECL quenchers. Within the effective distance of energy scavenging, the ECL quenching efficiency was dependent on the number of CdTe QDs doped into the silica NPs. Using ca. 200 CdTe QDs doped silica NPs on average of 40 nm in diameter as ECL quenching labels, attomolar detection of thrombin was successfully realized. The protein detection involves a competition binding event, based on thrombin replacing CdTe/SiO(2) NPs labeled probing DNA which is hybridized with capturing aptamer immobilized on a CdS:Mn NCs film modified glassy carbon electrode surface by specific aptamer-protein affinity interactions. It results in the displacement of ECL quenching labels from CdS:Mn NCs film and concomitant ECL signal recovery. Owing to the high-content CdTe QDs in silica NP, the increment of ECL intensity (ΔI(ECL)) and the concentration of thrombin showed a double logarithmic linear correlation in the range of 5.0 aM∼5.0 fM with a detection limit of 1aM. And, the aptasensor hardly responded to antibody, bovine serum albumin (BSA), haemoglobin (Hb) and lysozyme, showing good detection selectivity for thrombin. This long-distance energy scavenging could have a promising application perspective in the detection of biological recognition events on a molecular level.
Huang, Xiang; Li, Yuqin; Zhang, Xiaoshan; Zhang, Xin; Chen, Yaowen; Gao, Wenhua
2015-09-07
An efficient aptasensor was developed in which graphene oxide (GO) was employed as an indicator for both electrochemical impedance spectroscopy and electrochemiluminescence (ECL) signal generation. The aptasensor was fabricated by self-assembling the ECL probe of a thiolated adenosine triphosphate binding aptamer (ABA) tagged with a Ru complex (Ru(bpy)3(2+) derivatives) onto the surface of gold nanoparticle (AuNP) modified glassy carbon electrode (GCE). ABA immobilized onto AuNP modified GCE could strongly adsorb GO due to the strong π-π interaction between ABA and graphene oxide; ECL quenching of the Ru complex then takes place because of energy transfer and electron transfer, and a large increase of the electron transfer resistance (Ret) of the electrode. While in the presence of target adenosine triphosphate (ATP), the ABA prefers to form ABA-ATP bioaffinity complexes, which have weak affinity to graphene oxide and keep the graphene oxide away from the electrode surface, thus allowing the ECL signal enhancement, and in conjunction with the decrease of the Ret. Because of the high ECL quenching efficiency, unique structure, and electronic properties of graphene oxide, the Ret and ECL intensity versus the logarithm of ATP concentration was linear in the wide range from 10 pM to 10 nM with an ultra-low detection limit of 6.7 pM to 4.8 pM, respectively. The proposed aptasensor exhibited excellent reproducibility, stability, and outstanding selectivity, and ATP could be effectively distinguished from its analogues. More significantly, this efficient ECL aptasensor strategy based on GO acting both as an electrochemical and ECL signal indicator is general and can be easily extended to other biological binding events.
Cao, Jun-Tao; Yang, Jiu-Jun; Zhao, Li-Zhen; Wang, Yu-Ling; Wang, Hui; Liu, Yan-Ming; Ma, Shu-Hui
2018-01-15
A novel and competitive electrochemiluminescence (ECL) aptasensor for prostate specific antigen (PSA) assay was constructed using gold nanorods functionalized graphene oxide (GO@AuNRs) multilabeled with glucose oxidase (GOD) and streptavidin (SA) toward luminol-based ECL system. A strong initial ECL signal was achieved by electrodeposited gold (DpAu) on the electrode because of gold nanoparticles (AuNPs) motivating the luminol ECL signal. The signal probes prepared by loading GOD and SA-biotin-DNA on GO@AuNRs were used for achieving multiple signal amplification. In the absence of PSA, the signal probes can be attached on the electrode by hybridization reaction between PSA aptamer and biotin-DNA. In this state, the GOD loaded on the probe could catalyze glucose to in situ produce H 2 O 2 and then AuNRs catalyze H 2 O 2 to generate abundant reactive oxygen species (ROSs) in luminol ECL reaction. Both the high-content GOD and AuNRs in the signal probe amplified the ECL signal in the ECL system. Moreover, the combination of SA with biotin-DNA further expands ECL intensity. The integration of such amplifying effects in this protocol endows the aptasensor with high sensitivity and good selectivity for PSA detection. This aptasensor exhibits a linear relation in the range of 0.5pgmL -1 to 5.0ngmL -1 with the detection limit of 0.17pgmL -1 (S/N = 3). Besides, the strategy was successfully applied in determination of human serum samples with recovery of 81.4-116.0%. Copyright © 2017 Elsevier B.V. All rights reserved.
Results of Small-scale Solid Rocket Combustion Simulator testing at Marshall Space Flight Center
NASA Technical Reports Server (NTRS)
Goldberg, Benjamin E.; Cook, Jerry
1993-01-01
The Small-scale Solid Rocket Combustion Simulator (SSRCS) program was established at the Marshall Space Flight Center (MSFC), and used a government/industry team consisting of Hercules Aerospace Corporation, Aerotherm Corporation, United Technology Chemical Systems Division, Thiokol Corporation and MSFC personnel to study the feasibility of simulating the combustion species, temperatures and flow fields of a conventional solid rocket motor (SRM) with a versatile simulator system. The SSRCS design is based on hybrid rocket motor principles. The simulator uses a solid fuel and a gaseous oxidizer. Verification of the feasibility of a SSRCS system as a test bed was completed using flow field and system analyses, as well as empirical test data. A total of 27 hot firings of a subscale SSRCS motor were conducted at MSFC. Testing of the Small-scale SSRCS program was completed in October 1992. This paper, a compilation of reports from the above team members and additional analysis of the instrumentation results, will discuss the final results of the analyses and test programs.
NASA Technical Reports Server (NTRS)
Lewis, John F.; Barido, Richard A.; Cross, Cynthia D.; Rains, George Edward
2013-01-01
The Orion Multi-Purpose Crew Vehicle (MPCV) is the first crew transport vehicle to be developed by the National Aeronautics and Space Administration (NASA) in the last thirty years. Orion is currently being developed to transport the crew safely beyond Earth orbit. This year, the vehicle focused on building the Exploration Flight Test 1 (EFT1) vehicle to be launched in 2014. The development of the Orion Environmental Control and Life Support (ECLS) System, focused on the completing the components which are on EFT1. Additional development work has been done to keep the remaining component progressing towards implementation for a flight tests in of EM1 in 2017 and in and EM2 in 2020. This paper covers the Orion ECLS development from April 2012 to April 2013.
Orion Multi Purpose Crew Vehicle Environmental Control and Life Support Development Status
NASA Technical Reports Server (NTRS)
Lewis, John F.; Barido, Richard A.; Cross, Cynthia D.; Carrasquillo, Robyn; Rains, George Edward
2012-01-01
The Orion Multi Purpose Crew Vehicle (MPCV) is the first crew transport vehicle to be developed by the National Aeronautics and Space Administration (NASA) in the last thirty years. Orion is currently being developed to transport the crew safely from the Earth beyond Earth orbit. This year, the vehicle focused on building the Exploration Flight Test 1 (EFT1) vehicle to be launched in 2014. The development of the Orion Environmental Control and Life Support (ECLS) System, focused on the components which are on EFT1 which includes pressure control and active thermal control systems, is progressing through the design stage into manufacturing. Additional development work was done to keep the remaining component progressing towards implementation for a flight tests in 2017 and in 2020. This paper covers the Orion ECLS development from April 2011 to April 2012.
Multi Purpose Crew Vehicle Environmental Control and Life Support Development Status
NASA Technical Reports Server (NTRS)
Lewis, John F.; Barido, Richard A.; Cross, Cynthia D.; Carrasquillo, Robyn; Rains, George Edward
2011-01-01
The Orion Multi Purpose Crew Vehicle (MPCV) is the first crew transport vehicle to be developed by the National Aeronautics and Space Administration (NASA) in the last thirty years. Orion is currently being developed to transport the crew safely from the Earth beyond Earth orbit. This year, the vehicle focused on building the Orion Flight Test 1 (OFT1) vehicle to be launched in 2013. The development of the Orion Environmental Control and Life Support (ECLS) System, focused on the components which are on OFT1 which includes pressure control and active thermal control systems, is progressing through the design stage into manufacturing. Additional development work was done to keep the remaining component progressing towards implementation for a flight test in 2017. This paper covers the Orion ECLS development from April 2011 to April 2012.
Special education and later academic achievement.
Ehrhardt, Jennifer; Huntington, Noelle; Molino, Janine; Barbaresi, William
2013-02-01
To determine whether grade at entry to special education is associated with improved reading achievement in children with reading disorders (RD) and whether the effect of grade at entry to special education differs by socioeconomic status (SES). The authors conducted a secondary data analysis using data from the Early Childhood Longitudinal Study-Kindergarten Cohort (ECLS-K), a nationally representative cohort of children followed longitudinally from kindergarten through eighth grade (1998-2007). Using data from the fifth grade wave of ECLS-K, the authors identified children with RD (n = 290). The outcome of interest was change in score on the reading achievement test, which was developed by ECLS-K staff, between first and fifth grade. Using multiple linear regression, the authors modeled outcome as a function of a child's grade at entry to special education, controlling for several covariates. Early entry to special education (by first grade vs second or third grade) was associated with larger gains in reading achievement between first and fifth grade (p < .0001). Children who entered special education by first grade versus second grade gained 4.5 more points on the reading achievement test (p < .0001). Children who entered special education by first grade versus third grade gained 1.7 more points on the reading achievement test (p < .0001). There was no difference in the magnitude of gains associated with early entry to special education between children from families of low and higher SES. For children with RD, early entry to special education is associated with improved reading achievement during elementary school.
Performance of Planar-Waveguide External Cavity Laser for Precision Measurements
NASA Technical Reports Server (NTRS)
Numata, Kenji; Camp, Jordan; Krainak, Michael A.; Stolpner, Lew
2010-01-01
A 1542-nm planar-waveguide external cavity laser (PW-ECL) is shown to have a sufficiently low level of frequency and intensity noise to be suitable for precision measurement applications. The frequency noise and intensity noise of the PW-ECL was comparable or better than the nonplanar ring oscillator (NPRO) and fiber laser between 0.1 mHz to 100 kHz. Controllability of the PW-ECL was demonstrated by stabilizing its frequency to acetylene (13C2H2) at 10(exp -13) level of Allan deviation. The PW-ECL also has the advantage of the compactness of a standard butterfly package, low cost, and a simple design consisting of a semiconductor gain media coupled to a planar-waveguide Bragg reflector. These features would make the PW-ECL suitable for precision measurements, including compact optical frequency standards, space lidar, and space interferometry
Environmental Control and Life Support Systems Test Facility at MSFC
NASA Technical Reports Server (NTRS)
2001-01-01
The Marshall Space Flight Center (MSFC) is responsible for designing and building the life support systems that will provide the crew of the International Space Station (ISS) a comfortable environment in which to live and work. Scientists and engineers at the MSFC are working together to provide the ISS with systems that are safe, efficient, and cost-effective. These compact and powerful systems are collectively called the Environmental Control and Life Support Systems, or simply, ECLSS. This photograph shows the development Water Processor located in two racks in the ECLSS test area at the Marshall Space Flight Center. Actual waste water, simulating Space Station waste, is generated and processed through the hardware to evaluate the performance of technologies in the flight Water Processor design.
1967-01-01
NASA used barges for transporting full-sized stages for the Saturn I, Saturn IB, and Saturn V vehicles between the Marshall Space Flight Center (MSFC), the manufacturing plant at the Michoud Assembly Facility (MAF), the Mississippi Test Facility for testing, and the Kennedy Space Center. The barges traveled from the MSFC dock to the MAF, a total of 1,086.7 miles up the Tennessee River and down the Mississippi River. The barges also transported the assembled stages of the Saturn vehicle from the MAF to the Kennedy Space Center, a total of 932.4 miles along the Gulf of Mexico and up along the Atlantic Ocean, for the final assembly and the launch. Pictured is the barge Palaemon carrying Saturn IV S-IB flight stage enroute to MSFC.
1984-01-01
An engineer at the Marshall Space Flight Center (MSFC) observes a model of the Space Shuttle Orbiter being tested in the MSFC's 14x14-Inch Trisonic Wind Tunnel. The 14-Inch Wind Tunnel is a trisonic wind tunnel. This means it is capable of running subsonic, below the speed of sound; transonic, at or near the speed of sound (Mach 1,760 miles per hour at sea level); or supersonic, greater than Mach 1 up to Mach 5. It is an intermittent blowdown tunnel that operates by high pressure air flowing from storage to either vacuum or atmospheric conditions. The MSFC 14x14-Inch Trisonic Wind Tunnel has been an integral part of the development of the United States space program Rocket and launch vehicles from the Jupiter-C in 1958, through the Saturn family up to the current Space Shuttle and beyond have been tested in this Wind Tunnel. MSFC's 14x14-Inch Trisonic Wind Tunnel, as with most other wind tunnels, is named after the size of the test section. The 14-Inch Wind Tunnel, as in the past, will continue to play a large but unseen role in the development of America's space program.
Qi, Liming; Xia, Yong; Qi, Wenjing; Gao, Wenyue; Wu, Fengxia; Xu, Guobao
2016-01-19
Both a wireless electrochemiluminescence (ECL) electrode microarray chip and the dramatic increase in ECL by embedding a diode in an electromagnetic receiver coil have been first reported. The newly designed device consists of a chip and a transmitter. The chip has an electromagnetic receiver coil, a mini-diode, and a gold electrode array. The mini-diode can rectify alternating current into direct current and thus enhance ECL intensities by 18 thousand times, enabling a sensitive visual detection using common cameras or smart phones as low cost detectors. The detection limit of hydrogen peroxide using a digital camera is comparable to that using photomultiplier tube (PMT)-based detectors. Coupled with a PMT-based detector, the device can detect luminol with higher sensitivity with linear ranges from 10 nM to 1 mM. Because of the advantages including high sensitivity, high throughput, low cost, high portability, and simplicity, it is promising in point of care testing, drug screening, and high throughput analysis.
NASA Technical Reports Server (NTRS)
Perry, Jay L.; Arnold, William a.
2006-01-01
The design and operation of crewed spacecraft requires identifying and evaluating chemical compounds that may present reactivity and compatibility risks with the environmental control and life support (ECLS) system. Such risks must be understood so that appropriate design and operational controls, including specifying containment levels, can be instituted or an appropriate substitute material selected. Operational experience acquired during the International Space Station (ISS) program has found that understanding ECLS system and environmental impact presented by thermal control system working fluids is imperative to safely operating any crewed space exploration vehicle. Perfluorocarbon fluids are used as working fluids in thermal control fluid loops on board the ISS. Also, payload hardware developers have identified perfluorocarbon fluids as preferred thermal control working fluids. Interest in using perfluorocarbon fluids as thermal control system working fluids for future crewed space vehicles and outposts is high. Potential hazards associated with perfluorocarbon fluids are discussed with specific attention given to engineering assessment of ECLS system compatibility, compatibility testing results, and spacecraft environmental impact. Considerations for perfluorocarbon fluid use on crewed spacecraft and outposts are summarized.
Thermal control surfaces on the MSFC LDEF experiments
NASA Technical Reports Server (NTRS)
Wilkes, Donald R.; Whitaker, Ann F.; Zwiener, James M.; Linton, Roger C.; Shular, David; Peters, Palmer N.; Gregory, John C.
1992-01-01
There were five Marshall Space Flight Center (MSFC) experiments on the LDEF. Each of those experiments carried thermal control surfaces either as test samples or as operational surfaces. These materials experienced varying degrees of mechanical and optical damage. Some materials were virtually unchanged by the extended exposure while others suffered extensive degradation. The synergistic effects due to the constituents of the space environment are evident in the diversity of these material changes. The sample complement for the MSFC experiments is described along with results of the continuing analyses efforts.
NASA Technical Reports Server (NTRS)
Williams, David E.
2006-01-01
This paper will provide an overview of the International Space Station (ISS) Environmental Control and Life Support (ECLS) design of the Crew Health Care System (CHeCS) Rack 1 and it will document some of the lessons that have been learned to date for the ECLS equipment in this rack.
Xiong, Cheng-Yi; Wang, Hai-Jun; Liang, Wen-Bin; Yuan, Ya-Li; Yuan, Ruo; Chai, Ya-Qin
2015-06-26
Novel luminescence-functionalized metal-organic frameworks (MOFs) with superior electrogenerated chemiluminescence (ECL) properties were synthesized based on zinc ions as the central ions and tris(4,4'-dicarboxylicacid-2,2'-bipyridyl)ruthenium(II) dichloride ([Ru(dcbpy)3](2+)) as the ligands. For potential applications, the synthesized MOFs were used to fabricate a "signal-on" ECL immunosensor for the detection of N-terminal pro-B-type natriuretic peptide (NT-proBNP). As expected, enhanced ECL signals were obtained through a simple fabrication strategy because luminescence-functionalized MOFs not only effectively increased the loading of [Ru(dcbpy)3](2+), but also served as a loading platform in the ECL immunosensor. Furthermore, the proposed ECL immunosensor had a wide linear range from 5 pg mL(-1) to 25 ng mL(-1) and a relatively low detection limit of 1.67 pg mL(-1) (signal/noise=3). The results indicated that luminescence-functionalized MOFs provided a novel amplification strategy in the construction of ECL immunosensors and might have great prospects for application in bioanalysis. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Ma, Hongmin; Li, Xiaojian; Yan, Tao; Li, Yan; Liu, Haiyang; Zhang, Yong; Wu, Dan; Du, Bin; Wei, Qin
2016-02-23
In this work, a novel electrochemiluminescence (ECL) sensor based on Au nanoparticles-hybridized Pb (II)-β-cyclodextrin (Pb-β-CD) metal-organic framework for detecting hexavalent chromium (Cr(VI)) was developed. Pb-β-CD shows excellent ECL behavior and unexpected reducing ability towards Au ions. Au nanoparticles could massively form on the surface of Pb-β-CD (Au@Pb-β-CD) without use of any additional reducing agent. In the presence of coreactant K2S2O8, the ECL emission of Pb-β-CD was enhanced by the formation of Au nanoparticles. Cr(VI) can collisionally quench the ECL behavior of Au@Pb-β-CD/S2O8(2-) system and the detection mechanism was investigated. This ECL sensor is found to have a linear response in the range of 0.01-100 μM and a low detection limit of 3.43 nM (S/N = 3) under the optimal conditions. These results suggest that metal-organic framework Au@Pb-β-CD has great potential in extending the application in the ECL field as an efficient luminophore.
Mistry, A C; Honda, S; Hirose, S
2001-11-15
Using a Japanese-eel (Anguilla japonica) gill cDNA subtraction library, two novel beta-d-galactose-binding lectins were identified that belong to group VII of the animal C-type lectin family. The eel C-type lectins, termed eCL-1 and eCL-2, are simple lectins composed of 163 amino acid residues, including a 22-residue signal peptide for secretion and a single carbohydrate-recognition domain (CRD) of approximately 130 residues typical of C-type lectins. The galactose specificity of the CRD was suggested by the presence of a QPD motif and confirmed by a competitive binding assay. Using Ruthenium Red staining, the lectins were shown to bind Ca(2+) ions. SDS/PAGE showed that native eCL-1 and eCL-2 have an SDS-resistant octameric structure (a tetramer of disulphide-linked dimers). Northern and Western blot analyses demonstrated high-level expression of eCL-1 and eCL-2 mRNAs and their protein products in gills from freshwater eels, which decreased markedly when the eels were transferred from freshwater to seawater. Immunohistochemistry showed that the eel lectins are localized in the exocrine mucous cells of the gill.
Ma, Meng-Nan; Zhuo, Ying; Yuan, Ruo; Chai, Ya-Qin
2015-11-17
A highly sensitive electrochemiluminescent (ECL) aptasensor was constructed using semicarbazide (Sem) as co-reaction accelerator to promote the ECL reaction rate of CdTe quantum dots (CdTe QDs) and the co-reactant of peroxydisulfate (S2O8(2-)) for boosting signal amplification. The co-reaction accelerator is a species that when it is introduced into the ECL system containing luminophore and co-reactant, it can interact with co-reactant rather than luminophore to promote the ECL reaction rate of luminophore and co-reactant; thus the ECL signal is significantly amplified in comparison with that in which only luminophore and co-reactant are present. In this work, the ECL signal probes were first fabricated by alternately assembling the Sem and Au nanoparticles (AuNPs) onto the surfaces of hollow Au nanocages (AuNCs) via Au-N bond to obtain the multilayered nanomaterials of (AuNPs-Sem)n-AuNCs for immobilizing amino-terminated detection aptamer of thrombin (TBA2). Notably, the Sem with two -NH2 terminal groups could not only serve as cross-linking reagent to assemble AuNPs and AuNCs but also act as co-reaction accelerator to enhance the ECL reaction rate of CdTe QDs and S2O8(2-) for signal amplification. With the sandwich-type format, TBA2 signal probes could be trapped on the CdTe QD-based sensing interface in the presence of thrombin (TB) to achieve a considerably enhanced ECL signal in S2O8(2-) solution. As a result, the Sem in the TBA2 signal probes could accelerate the reduction of S2O8(2-) to produce the more oxidant mediators of SO4(•-), which further boosted the production of excited states of CdTe QDs to emit light. With the employment of the novel co-reaction accelerator Sem, the proposed ECL biosensor exhibited ultrahigh sensitivity to quantify the concentration of TB from 1 × 10(-7) to 1 nM with a detection limit of 0.03 fM, which demonstrated that the co-reaction accelerator could provide a simple, efficient, and low-cost approach for signal amplification and hold great potential for other ECL biosensors construction.
Ke, Hong; Sha, Haifeng; Wang, Yinfang; Guo, Weiwei; Zhang, Xin; Wang, Zhiming; Huang, Chusen; Jia, Nengqin
2018-02-15
Electrochemiluminescent (ECL) assay has gradually drawn increasing interest in the biomedical analysis. This paper proposed a new methodology for ultrasensitive and facile detection of Alzheimer's disease marker β-amyloid (Aβ) by fabricating a sandwich-type ECL sensing platform. Herein, electrochemiluminescence resonance energy transfer (ECL-RET) was employed to determine Aβ concentration, which can be attributed to the quenching effect from RET between Ru(bpy) 3 2+ and gold nanorods (GNRs) acting as ECL-RET electron donor and acceptor, respectively. In this protocol, mesoporous carbon nanospheres were adopted to immobilize ECL reactant Ru(bpy) 3 2+ and antibody via nafion to acquire the RET donor nanocomposites (MOCs/nafion/Ru(bpy) 3 2+ /antibody), which were tightly interconnected with epoxy group functionalized Fe 3 O 4 nanoparticles. It is of vital importance that GNRs with exquisite rod shape were synthesized and exhibited a typical absorption peak at 650nm to quench ECL signal of Ru(bpy) 3 2+ effectively. In addition, the ECL emission decreased linearly with the logarithm of Aβ concentration in a wide linear range from 1.0 × 10 -5 to 100ng/mL with a detection limit of 4.2 × 10 -6 ng/mL. Furthermore, distinctive and desirable properties were verified to declare the promise for being applicable to analyze the Aβ content in real Alzheimer's cerebrospinal fluid samples with satisfactory results. Copyright © 2017 Elsevier B.V. All rights reserved.
Implementation of Electronic Checklists in an Oncology Medical Record: Initial Clinical Experience
Albuquerque, Kevin V.; Miller, Alexis A.; Roeske, John C.
2011-01-01
Purpose: The quality of any medical treatment depends on the accurate processing of multiple complex components of information, with proper delivery to the patient. This is true for radiation oncology, in which treatment delivery is as complex as a surgical procedure but more dependent on hardware and software technology. Uncorrected errors, even if small or infrequent, can result in catastrophic consequences for the patient. We developed electronic checklists (ECLs) within the oncology electronic medical record (EMR) and evaluated their use and report on our initial clinical experience. Methods: Using the Mosaiq EMR, we developed checklists within the clinical assessment section. These checklists are based on the process flow of information from one group to another within the clinic and enable the processing, confirmation, and documentation of relevant patient information before the delivery of radiation therapy. The clinical use of the ECL was documented by means of a customized report. Results: Use of ECL has reduced the number of times that physicians were called to the treatment unit. In particular, the ECL has ensured that therapists have a better understanding of the treatment plan before the initiation of treatment. An evaluation of ECL compliance showed that, with additional staff training, > 94% of the records were completed. Conclusion: The ECL can be used to ensure standardization of procedures and documentation that the pretreatment checks have been performed before patient treatment. We believe that the implementation of ECLs will improve patient safety and reduce the likelihood of treatment errors. PMID:22043184
1967-10-01
S-IB-211, the flight version of the Saturn IB launch vehicle's first (S-IVB) stage, arrives at Marshall Space Flight Center's (MSFC's) S-IB static test stand. Between December 1967 and April 1968, the stage would undergo seven static test firings. The S-IB, developed by the MSFC and built by the Chrysler Corporation at the Michoud Assembly Facility near New Orleans, Louisiana, utilized eight H-1 engines and each produced 200,000 pounds of thrust.
1967-10-01
S-IB-211, the flight version of the Saturn IB launch vehicle's first (S-IVB) stage, on its way to Marshall Space Flight Center's (MSFC's) west test area. Between December 1967 and April 1968, the stage would undergo seven static test firings. The S-IB, developed by the MSFC and built by the Chrysler Corporation at the Michoud Assembly Facility near New Orleans, Louisiana, utilized eight H-1 engines and each produced 200,000 pounds of thrust.
1967-10-01
S-IB-211, the flight version of the Saturn IB launch vehicle's (S-IVB) first stage, after installation at the Marshall Space Flight Center's (MSFC's) S-IB static test stand. Between December 1967 and April 1968, the stage would undergo seven static test firings. The S-IB, developed by the MSFC and built by the Chrysler Corporation at the Michoud Assembly Facility near New Orleans, Louisiana, utilized eight H-1 engines and each produced 200,000 pounds of thrust.
MSFC Three Point Docking Mechanism design review
NASA Technical Reports Server (NTRS)
Schaefer, Otto; Ambrosio, Anthony
1992-01-01
In the next few decades, we will be launching expensive satellites and space platforms that will require recovery for economic reasons, because of initial malfunction, servicing, repairs, or out of a concern for post lifetime debris removal. The planned availability of a Three Point Docking Mechanism (TPDM) is a positive step towards an operational satellite retrieval infrastructure. This study effort supports NASA/MSFC engineering work in developing an automated docking capability. The work was performed by the Grumman Space & Electronics Group as a concept evaluation/test for the Tumbling Satellite Retrieval Kit. Simulation of a TPDM capture was performed in Grumman's Large Amplitude Space Simulator (LASS) using mockups of both parts (the mechanism and payload). Similar TPDM simulation activities and more extensive hardware testing was performed at NASA/MSFC in the Flight Robotics Laboratory and Space Station/Space Operations Mechanism Test Bed (6-DOF Facility).
Andrews, Jennifer; Winkler, Anne M
2016-10-01
For the past four decades, extracorporeal life support (ECLS) has been used to treat critically ill adult and pediatric patients with cardiac and/or respiratory failure, and there are increasingly numbers of centers worldwide performing ECLS for numerous indications. Despite the progress with advancing the technology, hemorrhagic and thrombotic complications are frequently reported and associated with worse outcomes, but the exact cause is often elusive or multifactorial. As a result of the interaction between blood and an artificial circuit, anticoagulation is necessary and there is resultant activation of coagulation, fibrinolysis, as well as, an increased inflammatory response. While unfractionated heparin (UFH) remains the mainstay anticoagulant used during ECLS, there is a paucity of published data to develop a universal anticoagulation guideline and centers are forced to create individualized protocols to guide anticoagulation management while lacking expertise. From an international survey, centers often use a combination of tests, which in turn result in discordant results and confused management. Studies are urgently needed to investigate optimization of current anticoagulation strategies with UFH, as well as, use of alternative anticoagulants and non-thrombogenic biomaterials. Blood transfusion during extracorporeal support typically occurs for several reasons, which includes circuit priming, restoration of oxygen carrying capacity, maintenance of a hemostatic balance, and treatment of hemorrhagic complications. As a result, the majority of patients will have been exposed to at least one blood product during extracorporeal support and transfusion utilization is high. ECLS Centers have adopted transfusion thresholds based upon practice rather than evidence as there have been no prospective studies investigating the efficacy of red cell (RBC) transfusion in patients receiving extracorporeal support. In addition, RBC transfusion has been associated with increased mortality in ECLS in several retrospective studies. Additional studies are needed to establish evidence based thresholds for transfusion support and diagnostics to guide transfusion therapy to assess efficacy of transfusion in this population, as well as, exploration of alternatives to transfusion. Copyright © 2016 Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Chernoff, Jodi Jacobson; Flanagan, Kristin Denton; McPhee, Cameron; Park, Jennifer
2007-01-01
The Early Childhood Longitudinal Study, Birth Cohort (ECLS-B) is designed to provide detailed information on children's development, health, and early learning experiences in the years leading up to entry into school. The ECLS-B is the first nationally representative study within the United States to directly assess children's early mental and…
Wagner, Georg; Schlanstein, Peter; Fiehe, Sandra; Kaufmann, Tim; Kopp, Rüdger; Bensberg, Ralf; Schmitz-Rode, Thomas; Steinseifer, Ulrich; Arens, Jutta
2014-04-01
Extracorporeal life support (ECLS) is a well-established technique for the treatment of different cardiac and pulmonary diseases, e.g., congenital heart disease and acute respiratory distress syndrome. Additionally, severely ill patients who cannot be weaned from the heart-lung machine directly after surgery have to be put on ECLS for further therapy. Although both systems include identical components, a seamless transition is not possible yet. The adaption of the circuit to the patients' size and demand is limited owing to the components available. The project I³-Assist aims at a novel concept for extracorporeal circulation. To better match the patient's therapeutic demand of support, an individual number of one-size oxygenators and heat exchangers will be combined. A seamless transition between cardiopulmonary bypass and ECLS will be possible as well as the exchange of components during therapy to enhance circuit maintenance throughout long-term support. Until today, a novel oxygenator and heat exchanger along with a simplified manufacturing protocol have been established. The first layouts of the unit to allow the spill- and bubble-free connection and disconnection of modules as well as improved cannulas and a rotational pump are investigated using computational fluid dynamics. Tests were performed according to current guidelines in vitro and in vivo. The test results show the feasibility and potential of the concept.
High Energy Astronomy Observatory (HEAO)
1977-06-01
This photograph is of the High Energy Astronomy Observatory (HEAO)-2 telescope being checked by engineers in the X-Ray Calibration Facility at the Marshall Space Flight Center (MSFC). The MSFC was heavily engaged in the technical and scientific aspects, testing and calibration, of the HEAO-2 telescope. The HEAO-2 was the first imaging and largest x-ray telescope built to date. The X-Ray Calibration Facility was built in 1976 for testing MSFC's HEAO-2. The facility is the world's largest, most advanced laboratory for simulating x-ray emissions from distant celestial objects. It produced a space-like environment in which components related to x-ray telescope imaging are tested and the quality of their performance in space is predicted. The original facility contained a 1,000-foot long by 3-foot diameter vacuum tube (for the x-ray path) cornecting an x-ray generator and an instrument test chamber. Recently, the facility was upgraded to evaluate the optical elements of NASA's Hubble Space Telescope, Chandra X-Ray Observatory and Compton Gamma-Ray Observatory.
Inhibited Shaped Charge Launcher Testing of Spacecraft Shield Designs
NASA Technical Reports Server (NTRS)
Grosch, Donald J.
1996-01-01
This report describes a test program in which several orbital debris shield designs were impact tested using the inhibited shaped charge launcher facility at Southwest Research Institute. This facility enables researchers to study the impact of one-gram aluminum projectiles on various shielding designs at velocities above 11 km/s. A total of twenty tests were conducted on targets provided by NASA-MSFC. This report discusses in detail the shield design, the projectile parameters and the test configuration used for each test. A brief discussion of the target damage is provided, as the detailed analysis of the target response will be done by NASA-MSFC.
Swirl Coaxial Injector Testing with LOX/RP-J
NASA Technical Reports Server (NTRS)
Greene, Sandra Elam; Casiano, Matt
2013-01-01
Testing was conducted at NASA fs Marshall Space Flight Center (MSFC) in the fall of 2012 to evaluate the operation and performance of liquid oxygen (LOX) and kerosene (RP ]1) in an existing swirl coaxial injector. While selected Russian engines use variations of swirl coaxial injectors, component level performance data has not been readily available, and all previously documented component testing at MSFC with LOX/RP ]1 had been performed using a variety of impinging injector designs. Impinging injectors have been adequate for specific LOX/RP ]1 engine applications, yet swirl coaxial injectors offer easier fabrication efforts, providing cost and schedule savings for hardware development. Swirl coaxial elements also offer more flexibility for design changes. Furthermore, testing with LOX and liquid methane propellants at MSFC showed that a swirl coaxial injector offered improved performance compared to an impinging injector. So, technical interest was generated to see if similar performance gains could be achieved with LOX/RP ]1 using a swirl coaxial injector. Results would allow such injectors to be considered for future engine concepts that require LOX/RP ]1 propellants. Existing injector and chamber hardware was used in the test assemblies. The injector had been tested in previous programs at MSFC using LOX/methane and LOX/hydrogen propellants. Minor modifications were made to the injector to accommodate the required LOX/RP ]1 flows. Mainstage tests were performed over a range of chamber pressures and mixture ratios. Additional testing included detonated gbombs h for stability data. Test results suggested characteristic velocity, C*, efficiencies for the injector were 95 ]97%. The injector also appeared dynamically stable with quick recovery from the pressure perturbations generated in the bomb tests.
1973-05-01
Engineers from the Marshall Space Flight Center (MSFC) and its contractors were testing the twin-pole sunshade at the Skylab mockup in the MSFC Building 4619. The Skylab Orbital Workshop (OWS) lost its thermal protection shield during launch on May 14, 1963. Without the heat shield, the temperature inside the OWS became dangerously high, rendering the workshop uninhabitable and threatened deterioration of the interior insulation and adhesive. Engineers from the MSFC, its contractors, and NASA persornel at other centers worked day and night for several days to develop the way to save the Skylab OWS. Eventually, they developed, tested, rehearsed, and approved three repair options. These options included a parasol sunshade and a twin-pole sunshade to restore the temperature inside the workshop, and a set of metal cutting tools to free the jammed solar panel.
The Development of MSFC Usability Lab
NASA Technical Reports Server (NTRS)
Cheng, Yiwei; Richardson, Sally
2010-01-01
This conference poster reviews the development of the usability lab at Marshall Space Flight Center. The purpose of the lab was to integrate a fully functioning usability laboratory to provide a resource for future human factor assessments. and to implement preliminary usability testing on a MSFC website to validate the functionality of the lab.
Detection of DNA hybridization by ABEI electrochemiluminescence in DNA-chip compatible assembly.
Calvo-Muñoz, M-L; Dupont-Filliard, A; Billon, M; Guillerez, S; Bidan, G; Marquette, C; Blum, L
2005-04-01
The electrochemiluminescence (ECL) of a luminol derivate (ABEI) generated both by a carbon electrode and a polypyrrole-coated carbon electrode was examined. It was found that the polypyrrole film (ppy) did not inhibit the ECL. After that, ABEI anchored on a single stranded DNA target (ODNt) has been used for the ECL detection of the hybridization between a complementary single stranded DNA probe (ODNp) covalently linked to a polypyrrole support and the ODNt. The ECL detection has been performed using a DNA sensor having a low surface concentration of ODNp probes, constituted of a polypyrrole copolymer electrosynthesized from a pyrrole-ODNp/pyrrole monomer ratio of 1/20,000.
International Space Station (ISS) Orbital Replaceable Unit (ORU) Wet Storage Risk Assessment
NASA Technical Reports Server (NTRS)
Squire, Michael D.; Rotter, Henry A.; Lee, Jason; Packham, Nigel; Brady, Timothy K.; Kelly, Robert; Ott, C. Mark
2014-01-01
The International Space Station (ISS) Program requested the NASA Engineering and Safety Center (NESC) to evaluate the risks posed by the practice of long-term wet storage of ISS Environmental Control and Life Support (ECLS) regeneration system orbital replacement units (ORUs). The ISS ECLS regeneration system removes water from urine and humidity condensate and converts it into potable water and oxygen. A total of 29 ORUs are in the ECLS system, each designed to be replaced by the ISS crew when necessary. The NESC assembled a team to review the ISS ECLS regeneration system and evaluate the potential for biofouling and corrosion. This document contains the outcome of the evaluation.
NASA Technical Reports Server (NTRS)
Lewis, John F.; Barido, Richard A.; Boehm, Paul; Cross, Cynthia D.; Rains, George Edward
2014-01-01
The Orion Multi Purpose Crew Vehicle (MPCV) is the first crew transport vehicle to be developed by the National Aeronautics and Space Administration (NASA) in the last thirty years. Orion is currently being developed to transport the crew safely beyond Earth orbit. This year, the vehicle focused on building the Exploration Flight Test 1 (EFT1) vehicle to be launched in September of 2014. The development of the Orion Active Thermal Control (ATCS) and Environmental Control and Life Support (ECLS) System, focused on the integrating the components into the EFT1 vehicle and preparing them for launch. Work also has started on preliminary design reviews for the manned vehicle. Additional development work is underway to keep the remaining component progressing towards implementation on the flight tests of EM1 in 2017 and of EM2 in 2020. This paper covers the Orion ECLS development from April 2013 to April 2014.
NASA Technical Reports Server (NTRS)
Lewis, John F.; Barido, Richard A.; Boehm, Paul; Cross, Cynthia D.; Rains, George Edward
2014-01-01
The Orion Multi Purpose Crew Vehicle (MPCV) is the first crew transport vehicle to be developed by the National Aeronautics and Space Administration (NASA) in the last thirty years. Orion is currently being developed to transport the crew safely beyond Earth orbit. This year, the vehicle focused on building the Exploration Flight Test 1 (EFT1) vehicle to be launched in September of 2014. The development of the Orion Active Thermal Control (ATCS) and Environmental Control and Life Support (ECLS) System, focused on the integrating the components into the EFT1 vehicle and preparing them for launch. Work also has started on preliminary design reviews for the manned vehicle. Additional development work is underway to keep the remaining component progressing towards implementation on the flight tests of EM1 in 2017 and of EM2 in 2020. This paper covers the Orion ECLS development from April 2013 to April 2014
Kitte, Shimeles Addisu; Wang, Chao; Li, Suping; Zholudov, Yuriy; Qi, Liming; Li, Jianping; Xu, Guobao
2016-10-01
Coreactant plays a critical role for the application of electrochemiluminescence (ECL). Herein, N-(3-aminopropyl)diethanolamine (APDEA) has been explored as a potential coreactant for enhancing tris(2,2'-bipyridyl)ruthenium(II) ECL. It is much more effective than tripropylamine at gold and platinum electrodes although it has one primary amine group besides a tertiary amine group. The presence of primary amine group and hydroxyl groups in APDEA promotes the oxidation rates of amine and thus remarkably increases ECL intensity. The ECL intensities of the Ru(bpy)3 (2+)/APDEA system are approximately 10 and 36 times stronger than that of Ru(bpy)3 (2+)/tripropylamine system and about 1.6 and 1.14 times stronger than that of Ru(bpy)3 (2+)/N-butyldiethanolamine system at Au and Pt electrodes, respectively. The ECL intensity of the Ru(bpy)3 (2+)/APDEA system is 2.42 times stronger than that of Ru(bpy)3 (2+)/N-butyldiethanolamine at glassy carbon electrodes.
Overview of MSFC AMSD Integrated Modeling and Analysis
NASA Technical Reports Server (NTRS)
Cummings, Ramona; Russell, Kevin (Technical Monitor)
2002-01-01
Structural, thermal, dynamic, and optical models of the NGST AMSD mirror assemblies are being finalized and integrated for predicting cryogenic vacuum test performance of the developing designs. Analyzers in use by the MSFC Modeling and Analysis Team are identified, with overview of approach to integrate simulated effects. Guidelines to verify the individual models and calibration cases for comparison with the vendors' analyses are presented. In addition, baseline and proposed additional scenarios for the cryogenic vacuum testing are briefly described.
ERIC Educational Resources Information Center
Walston, Jill; Rathbun, Amy; Hausken, Elvira Germino
2008-01-01
This report uses data from the Early Childhood Longitudinal Study, Kindergarten Class of 1998-99 (ECLS-K) to describe the middle school experiences of the cohort. The ECLS-K followed the educational, socioemotional, and physical development of a nationally representative sample of kindergartners in public and private schools in the United States…
Zhou, Zhenyu; Xu, Linru; Wu, Suozhu; Su, Bin
2014-10-07
Electrochemiluminescence (ECL) imaging provides a superior approach to achieve array detection because of its ability for ultrasensitive multiplex analysis. In this paper, we reported a novel ECL imaging biosensor array modified with an enzyme/carbon nanotubes/chitosan composite film for the determination of glucose, choline and lactate. The biosensor array was constructed by integrating a patterned indium tin oxide (ITO) glass plate with six perforated poly(dimethylsiloxane) (PDMS) covers. ECL is generated by the electrochemical reaction between luminol and hydrogen peroxide that is produced by the enzyme catalysed oxidation of different substrates with molecular oxygen, and ECL images were captured by a charge-coupled device (CCD) camera. The separated electrochemical micro-cells enabled simultaneous assay of six samples at different concentrations. From the established calibration curves, the detection limits were 14 μM for glucose, 40 μM for lactate and 97 μM for choline, respectively. Moreover, multicomponent assays and cross reactivity were also studied, both of which were satisfied for the analysis. This biosensing platform based on ECL imaging shows many distinct advantages, including miniaturization, low cost, and multi-functionalization. We believe that this novel ECL imaging biosensor platform will have potential applications in clinical diagnostics, medicine and food inspection.
Robinson, Wesley D; Richter, Mark M
2015-02-01
The spectroscopic, electrochemical and coreactant electrogenerated chemiluminescence (ECL) properties of Ir(ppy)3 (where ppy = 2-phenylpyridine) have been obtained in aqueous buffered (KH2PO4), 50 : 50 (v/v) acetonitrile-aqueous buffered (MeCN-KH2PO4) and 30% trifluoroethanol (TFE) solutions. Tri-n-propylamine was used as the oxidative-reductive ECL coreactant. The photoluminescence (PL) efficiency (ϕem) of Ir(ppy)3 in TFE (ϕem ≈ 0.029) was slightly higher than in 50 : 50 MeCN-KH2PO4 (ϕem ≈ 0.0021) and water (ϕem ≈ 0.00016) compared to a Ru(bpy)32+ standard solution in water (Φem ≈ 0.042). PL and ECL emission spectra were nearly identical in all three solvents, with dual emission maxima at 510 and 530 nm. The similarity between the ECL and PL spectra indicate that the same excited state is probably formed in both experiments. ECL efficiencies (ϕecl) in 30% TFE solution (ϕecl = 0.0098) were higher than aqueous solution (ϕecl = 0.00092) system yet lower than a 50% MeCN-KH2PO4 solution (ϕecl = 0.0091). Copyright © 2014 John Wiley & Sons, Ltd.
Mistry, A C; Honda, S; Hirose, S
2001-01-01
Using a Japanese-eel (Anguilla japonica) gill cDNA subtraction library, two novel beta-d-galactose-binding lectins were identified that belong to group VII of the animal C-type lectin family. The eel C-type lectins, termed eCL-1 and eCL-2, are simple lectins composed of 163 amino acid residues, including a 22-residue signal peptide for secretion and a single carbohydrate-recognition domain (CRD) of approximately 130 residues typical of C-type lectins. The galactose specificity of the CRD was suggested by the presence of a QPD motif and confirmed by a competitive binding assay. Using Ruthenium Red staining, the lectins were shown to bind Ca(2+) ions. SDS/PAGE showed that native eCL-1 and eCL-2 have an SDS-resistant octameric structure (a tetramer of disulphide-linked dimers). Northern and Western blot analyses demonstrated high-level expression of eCL-1 and eCL-2 mRNAs and their protein products in gills from freshwater eels, which decreased markedly when the eels were transferred from freshwater to seawater. Immunohistochemistry showed that the eel lectins are localized in the exocrine mucous cells of the gill. PMID:11695997
Chen, Xueqian; Gui, Wenying; Ma, Qiang
2018-06-07
In our work, a novel DNA electrochemiluminescence (ECL) sensor based on CuZnInS quantum dots (QDs) and gold-nanoparticles (Au NPs) is developed for highly sensitive detection of epidermal growth factor receptor (EGFR) Gene, which has a close relation with the lung cancer. The CuZnInS QDs work as a novel kind of ECL luminophore, whose defect state emission is suitable for ECL sensing. To enhance the sensitivity of the sensing system, Au NPs are utilized creatively to strengthen the ECL intensity of CuZnInS QD S according to the surface plasmon resonance (SPR) effect. An ultrasensitive and universal detecting platform is built based on the SPR effect between Au NPs and CuZnInS QD S . The effect of the capped stabilizer on the ECL signal of QDs is firstly investigated. Three different stabilizers are used to cap the CuZnInS QDs, including mercaptopropionic acid (MPA), l-glutathione (GSH) and cysteamine (CA). MPA capped CuZnInS QDs possess the strongest ECL intensity among the three kinds of the CuZnInS QDs. Under the optimum conditions, a good linear relationship between ECL intensity and the concentration of target DNA is obtained in the range from 0.05 nmol L -1 to 1 nmol L -1 . The detection limit is 0.0043 nmol L -1 . The proposed DNA sensor has been employed for the determination of target DNA EGFR in human serum samples with satisfactory results. Copyright © 2018 Elsevier B.V. All rights reserved.
Interstellar Message Plaques: Application of White-Light Holography
NASA Astrophysics Data System (ADS)
Matloff, G. L.
2002-01-01
During Spring / Summer 2001, a prototype white-light holographic interstellar-probe message plaque was created under Contract H-29712D of NASA Marshall Spaceflight Center (MSFC), and commercial white-light holograms were tested for space-radiation tolerance at the MSFC Space Environment Facility (SEF) in Huntsville, AL, USA. Artist C Bangs' message plaque was created at the Center for Holographic Arts in Long Island City, NY. The 57.5 X 47.5 cm rainbow hologram was delivered to MSFC after framing by Simon Liu Inc., Brooklyn, NY, USA. The prototype message plaque, which is in the collection of the MSFC Space Transportation Directorate, has six multiplexed 2-D and 3-D images representing humans, the hypothetical interstellar spacecraft, and our position in the galaxy. Consultation with John Caulfield of Fisk University, an expert in holography, revealed that micron-thick holograms not much larger than a sheet of paper could contain hundreds of thousands of images, which opens the me ssage-plaque field considerably so that work of many artists could be included. Tests of commercial holograms at up to 100 MRad of simulated solar-wind radiation were performed at MSFC / SEF. Image-quality deterioriation was monitored using the image-color- histogram of the (trademarked) Adobe Photoshop software package. No significant deterioration occurred, which is in agreement with the literature. Holographic solar sails may be a propulsive application of this technology.
E-Cigarette Affects the Metabolome of Primary Normal Human Bronchial Epithelial Cells
Aug, Argo; Altraja, Siiri; Kilk, Kalle; Porosk, Rando; Soomets, Ursel; Altraja, Alan
2015-01-01
E-cigarettes are widely believed to be safer than conventional cigarettes and have been even suggested as aids for smoking cessation. However, while reasonable with some regards, this judgment is not yet supported by adequate biomedical research data. Since bronchial epithelial cells are the immediate target of inhaled toxicants, we hypothesized that exposure to e-cigarettes may affect the metabolome of human bronchial epithelial cells (HBEC) and that the changes are, at least in part, induced by oxidant-driven mechanisms. Therefore, we evaluated the effect of e-cigarette liquid (ECL) on the metabolome of HBEC and examined the potency of antioxidants to protect the cells. We assessed the changes of the intracellular metabolome upon treatment with ECL in comparison of the effect of cigarette smoke condensate (CSC) with mass spectrometry and principal component analysis on air-liquid interface model of normal HBEC. Thereafter, we evaluated the capability of the novel antioxidant tetrapeptide O-methyl-l-tyrosinyl-γ-l-glutamyl-l-cysteinylglycine (UPF1) to attenuate the effect of ECL. ECL caused a significant shift in the metabolome that gradually gained its maximum by the 5th hour and receded by the 7th hour. A second alteration followed at the 13th hour. Treatment with CSC caused a significant initial shift already by the 1st hour. ECL, but not CSC, significantly increased the concentrations of arginine, histidine, and xanthine. ECL, in parallel with CSC, increased the content of adenosine diphosphate and decreased that of three lipid species from the phosphatidylcholine family. UPF1 partially counteracted the ECL-induced deviations, UPF1’s maximum effect occurred at the 5th hour. The data support our hypothesis that ECL profoundly alters the metabolome of HBEC in a manner, which is comparable and partially overlapping with the effect of CSC. Hence, our results do not support the concept of harmlessness of e-cigarettes. PMID:26536230
E-Cigarette Affects the Metabolome of Primary Normal Human Bronchial Epithelial Cells.
Aug, Argo; Altraja, Siiri; Kilk, Kalle; Porosk, Rando; Soomets, Ursel; Altraja, Alan
2015-01-01
E-cigarettes are widely believed to be safer than conventional cigarettes and have been even suggested as aids for smoking cessation. However, while reasonable with some regards, this judgment is not yet supported by adequate biomedical research data. Since bronchial epithelial cells are the immediate target of inhaled toxicants, we hypothesized that exposure to e-cigarettes may affect the metabolome of human bronchial epithelial cells (HBEC) and that the changes are, at least in part, induced by oxidant-driven mechanisms. Therefore, we evaluated the effect of e-cigarette liquid (ECL) on the metabolome of HBEC and examined the potency of antioxidants to protect the cells. We assessed the changes of the intracellular metabolome upon treatment with ECL in comparison of the effect of cigarette smoke condensate (CSC) with mass spectrometry and principal component analysis on air-liquid interface model of normal HBEC. Thereafter, we evaluated the capability of the novel antioxidant tetrapeptide O-methyl-l-tyrosinyl-γ-l-glutamyl-l-cysteinylglycine (UPF1) to attenuate the effect of ECL. ECL caused a significant shift in the metabolome that gradually gained its maximum by the 5th hour and receded by the 7th hour. A second alteration followed at the 13th hour. Treatment with CSC caused a significant initial shift already by the 1st hour. ECL, but not CSC, significantly increased the concentrations of arginine, histidine, and xanthine. ECL, in parallel with CSC, increased the content of adenosine diphosphate and decreased that of three lipid species from the phosphatidylcholine family. UPF1 partially counteracted the ECL-induced deviations, UPF1's maximum effect occurred at the 5th hour. The data support our hypothesis that ECL profoundly alters the metabolome of HBEC in a manner, which is comparable and partially overlapping with the effect of CSC. Hence, our results do not support the concept of harmlessness of e-cigarettes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jin, Qingwen; Agrawal, Lokesh; VanHorn-Ali, Zainab
2006-05-25
To analyze HTLV-1 cytotropism, we developed a highly sensitive vaccinia virus-based assay measuring activation of a reporter gene upon fusion of two distinct cell populations. We used this system in a functional cDNA screening to isolate and confirm that the glucose transporter protein 1 (GLUT-1) is a receptor for HTLV-1. GLUT-1 is a ubiquitously expressed plasma membrane glycoprotein with 12 transmembrane domains and 6 extracellular loops (ECL). We demonstrate for the first time that peptide antibodies (GLUT-IgY) raised in chicken to the large extracellular loop (ECL1) detect GLUT-1 at the cell surface and inhibit envelope (Env)-mediated fusion and infection. Efficientmore » GLUT-IgY staining was detected with peripheral blood CD4{sup +} lymphocytes purified by positive selection. Further, GLUT-IgY caused efficient inhibition of Env-mediated fusion and infection of CD4{sup +} T and significantly lower inhibition of CD8{sup +} T lymphocytes. The specificity of GLUT-IgY antibodies to GLUT-1 was demonstrated by ECL1 peptide competition studies. Grafting ECL1 of GLUT-1 onto the receptor-negative GLUT-3 conferred significant receptor activity. In contrast, grafting ECL1 of GLUT-3 onto GLUT-1 resulted in a significant loss of the receptor activity. The ECL1-mediated receptor activity was efficiently blocked with four different human monoclonal antibody (HMab) to HTLV-1 Env. The ECL1-derived peptide blocked HTLV-1 Env-mediated fusion with several nonhuman mammalian cell lines. The results demonstrate the utilization of cell surface GLUT-1 in HTLV-1 infection of CD4{sup +} T lymphocytes and implicate a critical role for the ECL1 region in viral tropism.« less
VUV Testing of Science Cameras at MSFC: QE Measurement of the CLASP Flight Cameras
NASA Technical Reports Server (NTRS)
Champey, Patrick; Kobayashi, Ken; Winebarger, Amy; Cirtain, Jonathan; Hyde, David; Robertson, Bryan; Beabout, Brent; Beabout, Dyana; Stewart, Mike
2015-01-01
The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras were built and tested for the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint National Astronomical Observatory of Japan (NAOJ) and MSFC sounding rocket mission. The CLASP camera design includes a frame-transfer e2v CCD57-10 512x512 detector, dual channel analog readout electronics and an internally mounted cold block. At the flight operating temperature of -20 C, the CLASP cameras achieved the low-noise performance requirements (less than or equal to 25 e- read noise and greater than or equal to 10 e-/sec/pix dark current), in addition to maintaining a stable gain of approximately equal to 2.0 e-/DN. The e2v CCD57-10 detectors were coated with Lumogen-E to improve quantum efficiency (QE) at the Lyman- wavelength. A vacuum ultra-violet (VUV) monochromator and a NIST calibrated photodiode were employed to measure the QE of each camera. Four flight-like cameras were tested in a high-vacuum chamber, which was configured to operate several tests intended to verify the QE, gain, read noise, dark current and residual non-linearity of the CCD. We present and discuss the QE measurements performed on the CLASP cameras. We also discuss the high-vacuum system outfitted for testing of UV and EUV science cameras at MSFC.
VUV testing of science cameras at MSFC: QE measurement of the CLASP flight cameras
NASA Astrophysics Data System (ADS)
Champey, P.; Kobayashi, K.; Winebarger, A.; Cirtain, J.; Hyde, D.; Robertson, B.; Beabout, B.; Beabout, D.; Stewart, M.
2015-08-01
The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras were built and tested for the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint MSFC, National Astronomical Observatory of Japan (NAOJ), Instituto de Astrofisica de Canarias (IAC) and Institut D'Astrophysique Spatiale (IAS) sounding rocket mission. The CLASP camera design includes a frame-transfer e2v CCD57-10 512 × 512 detector, dual channel analog readout and an internally mounted cold block. At the flight CCD temperature of -20C, the CLASP cameras exceeded the low-noise performance requirements (<= 25 e- read noise and <= 10 e- /sec/pixel dark current), in addition to maintaining a stable gain of ≍ 2.0 e-/DN. The e2v CCD57-10 detectors were coated with Lumogen-E to improve quantum efficiency (QE) at the Lyman- wavelength. A vacuum ultra-violet (VUV) monochromator and a NIST calibrated photodiode were employed to measure the QE of each camera. Three flight cameras and one engineering camera were tested in a high-vacuum chamber, which was configured to operate several tests intended to verify the QE, gain, read noise and dark current of the CCD. We present and discuss the QE measurements performed on the CLASP cameras. We also discuss the high-vacuum system outfitted for testing of UV, EUV and X-ray science cameras at MSFC.
Solar Thermal Propulsion Test Facility
NASA Technical Reports Server (NTRS)
1999-01-01
Researchers at the Marshall Space Flight Center (MSFC) have designed, fabricated and tested the first solar thermal engine, a non-chemical rocket engine that produces lower thrust but has better thrust efficiency than a chemical combustion engine. MSFC turned to solar thermal propulsion in the early 1990s due to its simplicity, safety, low cost, and commonality with other propulsion systems. Solar thermal propulsion works by acquiring and redirecting solar energy to heat a propellant. This photograph, taken at MSFC's Solar Thermal Propulsion Test Facility, shows a concentrator mirror, a combination of 144 mirrors forming this 18-ft diameter concentrator, and a vacuum chamber that houses the focal point. The 20- by 24-ft heliostat mirror (not shown in this photograph) has a dual-axis control that keeps a reflection of the sunlight on the 18-foot diameter concentrator mirror, which then focuses the sunlight to a 4-in focal point inside the vacuum chamber. The focal point has 10 kilowatts of intense solar power. As part of MSFC's Space Transportation Directorate, the Propulsion Research Center serves as a national resource for research of advanced, revolutionary propulsion technologies. The mission is to move the Nation's capabilities beyond the confines of conventional chemical propulsion into an era of aircraft-like access to Earth-orbit, rapid travel throughout the solar system, and exploration of interstellar space.
Smith, Todd G.; Ellison, James A.; Ma, Xiaoyue; Kuzmina, Natalia; Carson, William C.; Rupprecht, Charles E.
2015-01-01
Vaccine potency testing is necessary to evaluate the immunogenicity of inactivated rabies virus (RABV) vaccine preparations before human or veterinary application. Currently, the NIH test is recommended by the WHO expert committee to evaluate RABV vaccine potency. However, numerous disadvantages are inherent concerning cost, number of animals and biosafety requirements. As such, several in vitro methods have been proposed for the evaluation of vaccines based on RABV glycoprotein (G) quality and quantity, which is expected to correlate with vaccine potency. In this study an antigen-capture electrochemiluminescent (ECL) assay was developed utilizing anti-RABV G monoclonal antibodies (MAb) to quantify RABV G. One MAb 2-21-14 was specific for a conformational epitope so that only immunogenic, natively-folded G was captured in the assay. A second MAb (62-80-6) that binds a linear epitope or MAb 2-21-14 was used for detection of RABV G. Vaccine efficacy was also assessed in vivo using pre-exposure vaccination of mice. Purified native RABV G induced a RABV neutralizing antibody (rVNA) response with a geometric mean titer of 4.2 IU/ml and protected 100% of immunized mice against RABV challenge, while an experimental vaccine with a lower quality and quantity of G induced a rVNA titer <0.05 IU/ml and protected <50% of immunized mice. These preliminary results support the hypothesis that in vivo immunogenicity may be predicted from the in vitro measurement of RABV G using an ECL assay. Based upon these results, the ECL assay may have utility in replacement of the NIH test. PMID:23742991
1963-12-05
The test laboratory of the Marshall Space Flight Center (MSFC) tested the F-1 engine, the most powerful rocket engine ever fired at MSFC. The engine was tested on the newly modified Saturn IB Static Test Stand which had been used for three years to test the Saturn I eight-engine booster, S-I (first) stage. In 1961 the test stand was modified to permit static firing of the S-I/S-IB stage and the name of the stand was then changed to the S-IB Static Test Stand. Producing a combined thrust of 7,500,000 pounds, five F-1 engines powered the S-IC (first) stage of the Saturn V vehicle for the marned lunar mission.
1963-12-01
The test laboratory of the Marshall Space Flight Center (MSFC) tested the F-1 engine, the most powerful rocket engine ever fired at MSFC. The engine was tested on the newly modified Saturn IB static test stand that had been used for three years to test the Saturn I eight-engine booster, S-I (first) stage. In 1961, the test stand was modified to permit static firing of the S-I/S-IB stage and the name of the stand was then changed to the S-IB Static Test Stand. Producing a combined thrust of 7,500,000 pounds, five F-1 engines powered the S-IC (first) stage of the Saturn V vehicle for the marned lunar mission.
ERIC Educational Resources Information Center
Bethel, James; Green, James L.; Nord, Christine; Kalton, Graham; West, Jerry
2005-01-01
This report is Volume 2 of the methodology report that provides information about the development, design, and conduct of the 9-month data collection of the Early Childhood Longitudinal Study, Birth Cohort (ECLS-B). This volume begins with a brief overview of the ECLS-B, but focuses on the sample design, calculation of response rates, development…
A History of Spacecraft Environmental Control and Life Support Systems
NASA Technical Reports Server (NTRS)
Daues, Katherine R.
2006-01-01
A spacecraft's Environmental Control and Life Support (ECLS) system enables and maintains a habitable and sustaining environment for its crew. A typical ECLS system provides for atmosphere consumables and revitalization, environmental monitoring, pressure, temperature and humidity control, heat rejection (including equipment cooling), food and water supply and management, waste management, and fire detection and suppression. The following is a summary of ECLS systems used in United States (US) and Russian human spacecraft.
Film Processing Module for Automated Fiber Placement
NASA Technical Reports Server (NTRS)
Hulcher, A. Bruce
2004-01-01
This viewgraph presentation describes fiber placement technology which was originally developed by Marshall Space Flight Center (MSFC) for the fabrication of fiber composite propellant tanks. The presentation includes an image of the MSFC Fiber Placement Machine, which is a prototype test bed, and images of some of the machine's parts. Some possible applications for the machines are listed.
Space Environment Testing of Photovoltaic Array Systems at NASA's Marshall Space Flight Center
NASA Technical Reports Server (NTRS)
Schneider, Todd A.; Vaughn, Jason A.; Wright, Kenneth H., Jr.; Phillips, Brandon S.
2015-01-01
CubeSats, Communication Satellites, and Outer Planet Science Satellites all share one thing in common: Mission success depends on maintaining power in the harsh space environment. For a vast majority of satellites, spacecraft power is sourced by a photovoltaic (PV) array system. Built around PV cells, the array systems also include wiring, substrates, connectors, and protection diodes. Each of these components must function properly throughout the mission in order for power production to remain at nominal levels. Failure of even one component can lead to a crippling loss of power. To help ensure PV array systems do not suffer failures on-orbit due to the space environment, NASA's Marshall Space Flight Center (MSFC) has developed a wide ranging test and evaluation capability. Key elements of this capability include: Testing: a. Ultraviolet (UV) Exposure b. Charged Particle Radiation (Electron and Proton) c. Thermal Cycling d. Plasma and Beam Environments Evaluation: a. Electrostatic Discharge (ESD) Screening b. Optical Inspection and easurement c. PV Power Output including Large Area Pulsed Solar Simulator (LAPSS) measurements This paper will describe the elements of the space environment which particularly impact PV array systems. MSFC test capabilities will be described to show how the relevant space environments can be applied to PV array systems in the laboratory. A discussion of MSFC evaluation capabilities will also be provided. The sample evaluation capabilities offer test engineers a means to quantify the effects of the space environment on their PV array system or component. Finally, examples will be shown of the effects of the space environment on actual PV array materials tested at MSFC.
Yang, Minghui; Kostov, Yordan; Bruck, Hugh A; Rasooly, Avraham
2009-08-15
Staphylococcal enterotoxins (SEs) are major cause of foodborne diseases, so sensitive detection (<1 ng/ml) methods are needed for SE detection in food. The surface area, geometric and physical properties of gold nanoparticles make them well-suited for enhancing interactions with biological molecules in assays. To take advantage of the properties of gold nanoparticles for immunodetection, we have developed a gold nanoparticle-based enhanced chemiluminescence (ECL) immunosensor for detection of Staphylococcal Enterotoxin B (SEB) in food. Anti-SEB primary antibodies were immobilized onto a gold nanoparticle surface through physical adsorption and then the antibody-gold nanoparticle mixture was immobilized onto a polycarbonate surface. SEB was detected by a "sandwich-type" ELISA assay on the polycarbonate surface with a secondary antibody and ECL detection. The signal from ECL was read using a point-of-care detector based on a cooled charge-coupled device (CCD) sensor or a plate reader. The system was used to test for SEB in buffer and various foods (mushrooms, tomatoes, and baby food meat). The limit of detection was found to be approximately 0.01 ng/mL, which is approximately 10 times more sensitive than traditional ELISA. The gold nanoparticles were relatively easy to use for antibody immobilization because of their physical adsorption mechanism; no other reagents were required for immobilization. The use of our simple and inexpensive detector combined with the gold nanoparticle-based ECL method described here is adaptable to simplify and increase sensitivity of any immunological assay and for point-of-care diagnostics.
Yang, Minghui; Kostov, Yordan; Bruck, Hugh A.; Rasooly, Avraham
2010-01-01
Staphylococcal enterotoxins (SEs) are major cause of foodborne diseases, so sensitive detection (<1 ng/ml) methods are needed for SE detection in food. The surface area, geometric and physical properties of gold nanoparticles make them well-suited for enhancing interactions with biological molecules in assays. To take advantage of the properties of gold nanoparticles for immunodetection, we have developed a gold nanoparticle-based enhanced chemiluminescence (ECL) immunosensor for detection of Staphylococcal Enterotoxin B (SEB) in food. Anti-SEB primary antibodies were immobilized onto a gold nanoparticle surface through physical adsorption and then the antibody–gold nanoparticle mixture was immobilized onto a polycarbonate surface. SEB was detected by a “sandwich-type” ELISA assay on the polycarbonate surface with a secondary antibody and ECL detection. The signal from ECL was read using a point-of-care detector based on a cooled charge-coupled device (CCD) sensor or a plate reader. The system was used to test for SEB in buffer and various foods (mushrooms, tomatoes, and baby food meat). The limit of detection was found to be ~0.01 ng/mL, which is ~10 times more sensitive than traditional ELISA. The gold nanoparticles were relatively easy to use for antibody immobilization because of their physical adsorption mechanism; no other reagents were required for immobilization. The use of our simple and inexpensive detector combined with the gold nanoparticle-based ECL method described here is adaptable to simplify and increase sensitivity of any immunological assay and for point-of-care diagnostics. PMID:19540011
Development of low cost custom hybrid microcircuit technology
NASA Technical Reports Server (NTRS)
Perkins, K. L.; Licari, J. J.
1981-01-01
Selected potentially low cost, alternate packaging and interconnection techniques were developed and implemented in the manufacture of specific NASA/MSFC hardware, and the actual cost savings achieved by their use. The hardware chosen as the test bed for this evaluation ws the hybrids and modules manufactured by Rockwell International fo the MSFC Flight Accelerometer Safety Cut-Off System (FASCOS). Three potentially low cost packaging and interconnection alternates were selected for evaluation. This study was performed in three phases: hardware fabrication and testing, cost comparison, and reliability evaluation.
The Dynamics of the Evolution of the Black-White Test Score Gap
ERIC Educational Resources Information Center
Sohn, Kitae
2012-01-01
We apply a quantile version of the Oaxaca-Blinder decomposition to estimate the counterfactual distribution of the test scores of Black students. In the Early Childhood Longitudinal Study, Kindergarten Class of 1998-1999 (ECLS-K), we find that the gap initially appears only at the top of the distribution of test scores. As children age, however,…
A novel microRNA assay with optical detection and enzyme-free DNA circuits
NASA Astrophysics Data System (ADS)
Liao, Yuhui; Zhou, Xiaoming
2014-09-01
MicroRNAs (miRNAs) participate in the significant processes of life course, can be used as quantificational biomarkers for cellular level researches and related diseases. Conventional methods of miRNAs' quantitative detection are obsessed with low sensitivity, time and labour consuming. Otherwise, the emerging miRNAs detection approaches are mostly exposed to the expensive equipment demands and the professional operation, remains at the stage of laboratory and concept demonstration phase. Herein, we designed a novel miRNAs detection platform that based on enzyme-free DNA circuits and electrochemical luminescence (ECL). MicroRNA21 was chosen as the ideal analyte of this platform. The whole process consists of enzyme-free DNA circuits and ECL signal giving-out steps, achieves advantages of operating in constant temperature condition, without the participation of the enzyme, preferable sensitivity and specificity. Through this approach, the sensitivity achieved at 10pM. It is indicated that this miRNAs detection platform possesses potentials to be an innovation of miRNA detection technologies in routine tests. Benefits of the high penetration of ECL in well-equipped medical establishment, this approach could greatly lessen the obstacles in process of popularization and possess excellent prospects of practical application.
3D-Printed Supercapacitor-Powered Electrochemiluminescent Protein Immunoarray
Kadimisetty, Karteek; Mosa, Islam M.; Malla, Spundana; Satterwhite-Warden, Jennifer E.; Kuhns, Tyler; Faria, Ronaldo C.; Lee, Norman H.; Rusling, James F.
2015-01-01
Herein we report a low cost, sensitive, supercapacitor-powered electrochemiluminescent (ECL) protein immunoarray fabricated by an inexpensive 3-dimensional (3D) printer. The immunosensor detects three cancer biomarker proteins in serum within 35 min. The 3D-printed device employs hand screen printed carbon sensors with gravity flow for sample/reagent delivery and washing. Prostate cancer biomarker proteins, prostate specific antigen (PSA), prostate specific membrane antigen (PSMA) and platelet factor-4 (PF-4) in serum were captured on the antibody-coated carbon sensors followed by delivery of detection-antibody-coated Ru(bpy)32+ (RuBPY)-doped silica nanoparticles in a sandwich immunoassay. ECL light was initiated from RuBPY in the silica nanoparticles by electrochemical oxidation with tripropylamine (TPrA) co-reactant using supercapacitor power and ECL was captured with a CCD camera. The supercapacitor was rapidly photo-recharged between assays using an inexpensive solar cell. Detection limits were 300–500 fg mL−1 for the 3 proteins in undiluted calf serum. Assays of 6 prostate cancer patient serum samples gave good correlation with conventional single protein ELISAs. This technology could provide sensitive onsite cancer diagnostic tests in resource-limited settings with the need for only moderate-level training. PMID:26406460
NASA Astrophysics Data System (ADS)
Hedayat, A.; Cartagena, W.; Majumdar, A. K.; LeClair, A. C.
2016-03-01
NASA's future missions may require long-term storage and transfer of cryogenic propellants. The Engineering Development Unit (EDU), a NASA in-house effort supported by both Marshall Space Flight Center (MSFC) and Glenn Research Center, is a cryogenic fluid management (CFM) test article that primarily serves as a manufacturing pathfinder and a risk reduction task for a future CFM payload. The EDU test article comprises a flight-like tank, internal components, insulation, and attachment struts. The EDU is designed to perform integrated passive thermal control performance testing with liquid hydrogen (LH2) in a test-like vacuum environment. A series of tests, with LH2 as a testing fluid, was conducted at Test Stand 300 at MSFC during the summer of 2014. The objective of this effort was to develop a thermal/fluid model for evaluating the thermodynamic behavior of the EDU tank during the chill and fill processes. The Generalized Fluid System Simulation Program, an MSFC in-house general-purpose computer program for flow network analysis, was utilized to model and simulate the chill and fill portion of the testing. The model contained the LH2 supply source, feed system, EDU tank, and vent system. The test setup, modeling description, and comparison of model predictions with the test data are presented.
Charge Transport in the ClC-type Chloride-Proton Anti-porter from Escherichia coli*
Kieseritzky, Gernot; Knapp, Ernst-Walter
2011-01-01
The first chloride transporter identified in the superfamily of ClC chloride channels was from Escherichia coli (EClC) (Accardi, A., and Miller, C. (2004) Nature 427, 803–807). Pathways, energetics, and mechanism of proton and chloride translocation and their coupling are up to now unclear. To bridge the hydrophobic gap of proton transport, we modeled four stable buried waters into both subunits of the WT EClC structure. Together they form a “water wire” connecting Glu-203 with the chloride at the central site, which in turn connects to Glu-148, the hypothetical proton exit site. Assuming the transient production of hydrochloride in the central chloride binding site of EClC, the water wire could establish a transmembrane proton transport pathway starting from Glu-203 all the way downstream onto Glu-148. We demonstrated by electrostatic and quantum chemical computations that protonation of the central chloride is energetically feasible. We characterized all chloride occupancies and protonation states possibly relevant for the proton-chloride transport cycle in EClC and constructed a working model. Accordingly, EClC evolves through states involving up to two excess protons and between one and three chlorides, which was required to fulfill the experimentally observed 2:1 stoichiometry. We show that the Y445F and E203H mutants of EClC can operate similarly, thus explaining why they exhibit almost WT activity levels. The proposed mechanism of coupled chloride-proton transport in EClC is consistent with available experimental data and allows predictions on the importance of specific amino acids, which may be probed by mutation experiments. PMID:21059656
Hematological complications in children subjected to extracorporeal membrane oxygenation.
Santiago, M J; Gómez, C; Magaña, I; Muñoz, V; Saiz, P; Sánchez, A; López-Herce, J
2018-03-29
To analyze the hematological complications and need for transfusions in children receiving extracorporeal life support (ECLS). A retrospective study was carried out. A pediatric intensive care unit. Children under 18 years of age treated with ECLS between September 2006 and November 2015. None. Patient and ECLS characteristics, anticoagulation, hematological and coagulation parameters, transfusions and clinical course. A total of 100 patients (94 with heart disease) with a median age of 11 months were studied. Seventy-six patients presented bleeding. The most frequent bleeding point being the mediastinum and 39 patients required revision surgery. In the first 3days, 97% of the patients required blood transfusion (34.4ml/kg per day), 94% platelets (21.1ml/kg per day) and 90% plasma (26.6ml/kg per day). Patients who were in the postoperative period, those who were bleeding at the start of ECLS, those requiring revision surgery, those who could not suspend extracorporeal circulation, and those subjected to transthoracic cannulation required a greater volume of transfusions than the rest of the patients. Thromboembolism occurred in 14 patients and hemolysis in 33 patients. Mortality among the children who were bleeding at the start of ECLS (57.6%) was significantly higher than in the rest of the patients (37.5%) (P=0.048). Children treated with ECLS present high blood product needs. The main factors related to transfusions were postoperative period, bleeding at the start of ECLS, revision surgery, transthoracic cannulation, and the impossibility of suspending extracorporeal circulation. Children with bleeding suffered greater mortality than the rest of the patients. Copyright © 2018 Elsevier España, S.L.U. y SEMICYUC. All rights reserved.
ERIC Educational Resources Information Center
Tourangeau, Karen; Nord, Christine; Lê, Thanh; Wallner-Allen, Kathleen; Vaden-Kiernan, Nancy; Blaker, Lisa; Najarian, Michelle
2017-01-01
This manual provides guidance and documentation for users of the longitudinal kindergarten-second grade (K-2) data file of the Early Childhood Longitudinal Study, Kindergarten Class of 2010-11 (ECLS-K:2011). It mainly provides information specific to the second-grade rounds of data collection. Users should refer to the "Early Childhood…
ERIC Educational Resources Information Center
Tourangeau, Karen; Nord, Christine; Lê, Thanh; Wallner-Allen, Kathleen; Vaden-Kiernan, Nancy; Blaker, Lisa; Najarian, Michelle
2018-01-01
This manual provides guidance and documentation for users of the longitudinal kindergarten-fourth grade (K-4) data file of the Early Childhood Longitudinal Study, Kindergarten Class of 2010-11 (ECLS-K:2011). It mainly provides information specific to the fourth-grade round of data collection. The first chapter provides an overview of the…
NASA Astrophysics Data System (ADS)
Jiang, Xinya; Wang, Huijun; Wang, Haijun; Zhuo, Ying; Yuan, Ruo; Chai, Yaqin
2016-04-01
Herein, a self-enhanced N-(aminobutyl)-N-(ethylisoluminol) (ABEI) derivative-based electrochemiluminescence (ECL) immunosensor was constructed for the determination of laminin (LN) using PdIr cubes as a mimic peroxidase for signal amplification. Initially, PdIr cubes with efficient peroxidase mimicking properties, large specific surface areas, and good stability and uniformity were synthesized. Then, l-cysteine (l-Cys) and ABEI were immobilized on the PdIr cubes to form the self-enhanced ECL nanocomplex (PdIr-l-Cys-ABEI). In this nanocomplex, PdIr cubes, whose catalytic constant is higher than that of horseradish peroxidase (HRP), could effectively catalyze H2O2 decomposition and thus enhance the ECL intensity of ABEI. Moreover, PdIr cubes can be easily modified with functional groups, which make them adaptable to desired supported platforms. On the other hand, l-Cys as a coreactant of ABEI could effectively enhance the luminous efficiency due to the intramolecular ECL reaction which could reduce the energy loss between l-Cys and ABEI by giving a shorter electron transfer distance. The developed strategy combined an ABEI derivative as a self-enhanced ECL luminophore and PdIr cubes as a mimic peroxidase, resulting in a significantly enhanced ECL signal output. Also, the strategy showed high sensitivity and selectivity for LN, which suggested that our new approach could be potentially applied in monitoring different proteins.
Kortchinsky, Talna; Mussot, Sacha; Rezaiguia, Saïda; Artiguenave, Margaux; Fadel, Elie; Stephan, François
2016-09-01
After bilateral lung and heart-lung transplantation in adults with pulmonary hypertension, hemodynamic and oxygenation deficiencies are life-threatening complications that are increasingly managed with extracorporeal life support (ECLS). The primary aim of this retrospective study was to assess 30-day and 1-year survival rates in patients managed with vs without post-operative venoarterial ECLS in 2008-2013. The secondary endpoints were the occurrence rates of nosocomial infection, bleeding, and acute renal failure. Of the 93 patients with pulmonary hypertension who received heart-lung (n=29) or bilateral lung (n=64) transplants, 28 (30%) required ECLS a median of 0 [0-6] hours after surgery completion and for a median of 3.0 [2.0-8.5] days. Compared to ECLS patients, controls had higher survival at 30 days (95.0% vs 78.5%; P=.02) and 1 year (83% vs 64%; P=.005), fewer nosocomial infections (48% vs 79%; P=.0006), and fewer bleeding events (17% vs 43%; P=.008). The need for renal replacement therapy was not different between groups (11% vs 17%; P=.54). Venoarterial ECLS is effective in treating pulmonary graft dysfunction with hemodynamic failure after heart-lung or bilateral lung. However, ECLS use was associated with higher rates of infection and bleeding. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Effects of 5 years of treatment with rabeprazole or omeprazole on the gastric mucosa.
Rindi, Guido; Fiocca, Roberto; Morocutti, Anna; Jacobs, Adam; Miller, Neil; Thjodleifsson, Bjarni
2005-05-01
Prolonged gastric acid suppression leads to hypergastrinaemia, which promotes hyperplasia of the enterochromaffin-like (ECL) cells of the oxyntic mucosa. The objective was to determine the effects of 5 years of treatment with rabeprazole or omeprazole on the gastric mucosa. Two hundred and forty-three patients received rabeprazole (20 mg or 10 mg) or omeprazole (20 mg) once daily for up to 5 years, for gastro-oesophageal reflux disease and 51% completed the whole 5 year period. Gastric biopsy specimens were taken and examined for gastritis, Helicobacter pylori infection, and ECL cell status. H. pylori infection in the gastric corpus was more common than in the antrum, and remained constant, whereas antral H. pylori infection became less common as the study progressed. H. pylori infection was a highly significant predictor of higher gastritis scores, which were similar among the three treatment groups. ECL cell hyperplasia occurred in a minority of patients, and was associated with serum gastrin concentrations. No ECL cell dysplasia or tumours were observed. There were no significant differences among the treatment groups in gastritis or ECL cell hyperplasia grades. This study has confirmed the link between ECL cell hyperplasia and elevated serum gastrin concentrations, but has found no evidence that this progresses to high grades of hyperplasia during 5 years of treatment with rabeprazole or omeprazole.
Valenti, Giovanni; Rampazzo, Enrico; Biavardi, Elisa; Villani, Elena; Fracasso, Giulio; Marcaccio, Massimo; Bertani, Federico; Ramarli, Dunia; Dalcanale, Enrico; Paolucci, Francesco; Prodi, Luca
2015-01-01
Monitoring Prostate Cancer (PCa) biomarkers is an efficient way to diagnosis this disease early, since it improves the therapeutic success rate and suppresses PCa patient mortality: for this reason a powerful analytical technique such as electrochemiluminescence (ECL) is already used for this application, but its widespread usability is still hampered by the high cost of commercial ECL equipment. We describe an innovative approach for the selective and sensitive detection of the PCa biomarker sarcosine, obtained by a synergistic ECL-supramolecular approach, in which the free base form of sarcosine acts as co-reagent in a Ru(bpy)3(2+)-ECL process. We used magnetic micro-beads decorated with a supramolecular tetraphosphonate cavitand (Tiiii) for the selective capture of sarcosine hydrochloride in a complex matrix like urine. Sarcosine determination was then obtained with ECL measurements thanks to the complexation properties of Tiiii, with a protocol involving simple pH changes - to drive the capture-release process of sarcosine from the receptor - and magnetic micro-bead technology. With this approach we were able to measure sarcosine in the μM to mM window, a concentration range that encompasses the diagnostic urinary value of sarcosine in healthy subjects and PCa patients, respectively. These results indicate how this ECL-supramolecular approach is extremely promising for the detection of sarcosine and for PCa diagnosis and monitoring, and for the development of portable and more affordable devices.
1965-01-01
The Saturn V first stages were test fired at the Mississippi Test Facility and at the Marshall Space Flight Center (MSFC). Five F-1 engines powered the first stage, each developing 1.5 million pounds of thrust. The first stage, known as the S-IC stage, burned over 15 tons of propellant per second during its 2.5 minutes of operation to take the vehicle to a height of about 36 miles and to a speed of about 6,000 miles per hour. The stage was 138 feet long and 33 feet in diameter. This photograph shows the test firing of an F-1 engine at the MSFC's S-IC Static Test Firing Facility.
Evaluation of Chemical Coating Processes for AXAF
NASA Technical Reports Server (NTRS)
Engelhaupt, Darell; Ramsey, Brian; Mendrek, Mitchell
1998-01-01
The need existed at MSFC for the development and fabrication of radioisotope calibration sources of cadmium 109 and iron 55 isotopes. This was in urgent response to the AXA-F program. Several issues persisted in creating manufacturing difficulties for the supplier. In order to meet the MSFC requirements very stringent control needed to be maintained for the coating quality, specific activity and thickness. Due to the difficulties in providing the precisely controlled devices for testing, the delivery of the sources was seriously delayed. It became imperative that these fabrication issues be resolved to avoid further delays in this AXA-F observatory key component. The objectives are: 1) Research and provide expert advice on coating materials and procedures. 2) Research and recommend solutions to problems that have been experienced with the coating process. 3) Provide recommendations on the selection and preparation of substrates. 4) Provide consultation on the actual coating process including the results of the qualification and acceptance test programs. 5) Perform independent tests at UAH or MSFC as necessary.
Gao, Ying; Liu, Xiaoyun; Qi, Wenjing; Gao, Wenyue; Li, Yunhui; Xu, Guobao
2015-06-21
Most electrochemiluminescence (ECL) systems require high concentrations of quencher to totally quench ECL. In this study, we found that ozone can quench tris(2,2'-bipyridyl)ruthenium(II) ECL using formaldehyde, methylglyoxal, or glyoxalate as co-reactants at a glassy carbon electrode with remarkable efficiencies even when the concentration of ozone is merely 0.25% of that of the co-reactant. The strongest quenching is observed with the tris(2,2'-bipyridyl)ruthenium(II)/formaldehyde ECL system. The tris(2,2'-bipyridyl)ruthenium(II)/formaldehyde ECL intensities decrease linearly with the ozone concentration over the range of 0.025-25 μM (r = 0.9947) with a limit of detection of 8 nM. The method is more sensitive and faster than most methods. It shows high selectivity in the presence of other ROS or oxidants and some metal ions, such as H2O2, ClO(-), Mg(2+), Ni(2+), etc. The method exhibits high recoveries for the detection of ozone in a ventilated photocopy room.
1964-12-01
At the Marshall Space Flight Center (MSFC), the fuel tank assembly for the Saturn V S-IC-T (static test stage) fuel tank assembly is mated to the liquid oxygen (LOX) tank in building 4705. This stage underwent numerous static firings at the newly-built S-IC Static Test Stand at the MSFC west test area. The S-IC (first) stage used five F-1 engines that produced a total thrust of 7,500,000 pounds as each engine produced 1,500,000 pounds of thrust. The S-IC stage lifted the Saturn V vehicle and Apollo spacecraft from the launch pad.
1970-03-20
Under the direction of Marshall Space Flight Center (MSFC), the Lunar Roving Vehicle (LRV) was designed to allow Apollo astronauts a greater range of mobility during lunar exploration missions. During the development process, LRV prototype wheels underwent soil tests in building 4481 at Marshall Space Flight Center (MSFC). Pictured from left to right are the wheels for: LRV, Bendix Corporation, Local Scientific Survey Module (LSSM), and Grumman Industries.
International Space Station (ISS)
2001-02-01
The Marshall Space Flight Center (MSFC) is responsible for designing and building the life support systems that will provide the crew of the International Space Station (ISS) a comfortable environment in which to live and work. Scientists and engineers at the MSFC are working together to provide the ISS with systems that are safe, efficient, and cost-effective. These compact and powerful systems are collectively called the Environmental Control and Life Support Systems, or simply, ECLSS. In this photograph, the life test area on the left of the MSFC ECLSS test facility is where various subsystems and components are tested to determine how long they can operate without failing and to identify components needing improvement. Equipment tested here includes the Carbon Dioxide Removal Assembly (CDRA), the Urine Processing Assembly (UPA), the mass spectrometer filament assemblies and sample pumps for the Major Constituent Analyzer (MCA). The Internal Thermal Control System (ITCS) simulator facility (in the module in the right) duplicates the function and operation of the ITCS in the ISS U.S. Laboratory Module, Destiny. This facility provides support for Destiny, including troubleshooting problems related to the ITCS.
High Energy Astronomy Observatory (HEAO)
1977-01-01
This photograph is of the High Energy Astronomy Observatory (HEAO)-2 telescope being evaluated by engineers in the clean room of the X-Ray Calibration Facility at the Marshall Space Flight Center (MSFC). The MSFC was heavily engaged in the technical and scientific aspects, testing and calibration, of the HEAO-2 telescope The HEAO-2 was the first imaging and largest x-ray telescope built to date. The X-Ray Calibration Facility was built in 1976 for testing MSFC's HEAO-2. The facility is the world's largest, most advanced laboratory for simulating x-ray emissions from distant celestial objects. It produced a space-like environment in which components related to x-ray telescope imaging are tested and the quality of their performance in space is predicted. The original facility contained a 1,000-foot long by 3-foot diameter vacuum tube (for the x-ray path) cornecting an x-ray generator and an instrument test chamber. Recently, the facility was upgraded to evaluate the optical elements of NASA's Hubble Space Telescope, Chandra X-Ray Observatory and Compton Gamma-Ray Observatory.
NASA Technical Reports Server (NTRS)
Bradley, D.; Ellis, R. R.
1972-01-01
A 0.00227-scale parametric model of an LMSC/MSFC water recoverable booster was tested in the MSFC 14 x 14-inch trisonic wind tunnel. The purpose of the test was to obtain high angle of attack force and static stability data which could be used by MSFC in preliminary design and aerodynamic trade studies. These data were obtained using six-component internal strain gauge balances. One hundred forty-four different geometrical combinations were possible as all model parts were interchangeable (three nose cones, three cylinder lengths, four flare sections and three sets of fins, plus a no-fin case in combination with the other components). However, due to tunnel occupancy limitations, only the most representative combinations were tested. All configurations investigated were tested at Mach 1.96, 2.74 and 4.96 with data obtained at angles of attack from 50 degrees to 90 degrees and at angles of sideslip from -10 degrees to +10 degrees (at an angle of attack of 60 degrees).
Regeneratively Cooled Liquid Oxygen/Methane Technology Development Between NASA MSFC and PWR
NASA Technical Reports Server (NTRS)
Robinson, Joel W.; Greene, Christopher B.; Stout, Jeffrey B.
2012-01-01
The National Aeronautics & Space Administration (NASA) has identified Liquid Oxygen (LOX)/Liquid Methane (LCH4) as a potential propellant combination for future space vehicles based upon exploration studies. The technology is estimated to have higher performance and lower overall systems mass compared to existing hypergolic propulsion systems. NASA-Marshall Space Flight Center (MSFC) in concert with industry partner Pratt & Whitney Rocketdyne (PWR) utilized a Space Act Agreement to test an oxygen/methane engine system in the Summer of 2010. PWR provided a 5,500 lbf (24,465 N) LOX/LCH4 regenerative cycle engine to demonstrate advanced thrust chamber assembly hardware and to evaluate the performance characteristics of the system. The chamber designs offered alternatives to traditional regenerative engine designs with improvements in cost and/or performance. MSFC provided the test stand, consumables and test personnel. The hot fire testing explored the effective cooling of one of the thrust chamber designs along with determining the combustion efficiency with variations of pressure and mixture ratio. The paper will summarize the status of these efforts.
Additively Manufactured Combustion Devices Components for LOX/Methane Applications
NASA Technical Reports Server (NTRS)
Greene, Sandra Elam; Protz, Christopher; Garcia, Chance; Goodman, Dwight; Baker, Kevin
2016-01-01
Marshall Space Flight Center (MSFC) has designed, fabricated, and hot-fire tested a variety of successful injectors, chambers, and igniters for potential liquid oxygen (LOX) and methane (CH4) systems since 2005. The most recent efforts have focused on components with additive manufacturing (AM) to include unique design features, minimize joints, and reduce final machining efforts. Inconel and copper alloys have been used with AM processes to produce a swirl coaxial injector and multiple methane cooled thrust chambers. The initial chambers included unique thermocouple ports for measuring local coolant channel temperatures along the length of the chamber. Results from hot-fire testing were used to anchor thermal models and generate a regeneratively cooled thruster for a 4,000 lbf LOX/CH4 engine. The completed thruster will be hot-fire tested in the summer of 2016 at MSFC. The thruster design can also be easily scaled and used on a 25,000 lbf engine. To further support the larger engine design, an AM gas generator injector has been designed. Hot-fire testing on this injector is planned for the summer of 2016 at MSFC.
1999-11-01
This photograph shows an overall view of the Solar Thermal Propulsion Test Facility at the Marshall Space Flight Center (MSFC). The 20-by 24-ft heliostat mirror, shown at the left, has dual-axis control that keeps a reflection of the sunlight on an 18-ft diameter concentrator mirror (right). The concentrator mirror then focuses the sunlight to a 4-in focal point inside the vacuum chamber, shown at the front of concentrator mirror. Researchers at MSFC have designed, fabricated, and tested the first solar thermal engine, a non-chemical rocket engine that produces lower thrust but has better thrust efficiency than chemical a combustion engine. MSFC turned to solar thermal propulsion in the early 1990s due to its simplicity, safety, low cost, and commonality with other propulsion systems. Solar thermal propulsion works by acquiring and redirecting solar energy to heat a propell nt. As part of MSFC's Space Transportation Directorate, the Propulsion Research Center serves as a national resource for research of advanced, revolutionary propulsion technologies. The mission is to move the Nation's capabilities beyond the confines of conventional chemical propulsion into an era of aircraft-like access to Earth-orbit, rapid travel throughout the solar system, and exploration of interstellar space.
NASA Technical Reports Server (NTRS)
Holder, Donald W., Jr.; Bagdigian, Robert M.
1992-01-01
A series of tests has been conducted at the NASA Marshall Space Flight Center (MSFC) to evaluate the performance of a Space Station Freedom (SSF) pre-development water recovery system. Potable, hygiene, and urine reclamation subsystems were integrated with end-use equipment items and successfully operated for a total of 35 days, including 23 days in closed-loop mode with man-in-the-loop. Although several significant subsystem physical anomalies were encountered, reclaimed potable and hygiene water routinely met current SSF water quality specifications. This paper summarizes the test objectives, system design, test activities/protocols, significant results/anomalies, and major lessons learned.
Induction of HIV-blocking anti-CCR5 IgA in Peyers's patches without histopathological alterations.
Pastori, Claudia; Diomede, Lorenzo; Venuti, Assunta; Fisher, Gregory; Jarvik, Jonathan; Bomsel, Morgane; Sanvito, Francesca; Lopalco, Lucia
2014-04-01
The chemokine receptor CCR5 is essential for HIV infection and is thus a potential target for vaccine development. However, because CCR5 is a host protein, generation of anti-CCR5 antibodies requires the breaking of immune tolerance and thus carries the risk of autoimmune responses. In this study, performed in mice, we compared 3 different immunogens representing surface domains of murine CCR5, 4 different adjuvants, and 13 different immunization protocols, with the goal of eliciting HIV-blocking activity without inducing autoimmune dysfunction. In all cases the CCR5 sequences were presented as fusions to the Flock House virus (FHV) capsid precursor protein. We found that systemic immunization and mucosal boosting elicited CCR5-specific antibodies and achieved consistent priming in Peyer's patches, where most cells showed a phenotype corresponding to activated B cells and secreted high levels of IgA, representing up to one-third of the total HIV-blocking activity. Histopathological analysis revealed mild to moderate chronic inflammation in some tissues but failed in reporting signs of autoimmune dysfunction associated with immunizations. Antisera against immunogens representing the N terminus and extracellular loops 1 and 2 (Nter1 and ECL1 and ECL2) of CCR5 were generated. All showed specific anti-HIV activity, which was stronger in the anti-ECL1 and -ECL2 sera than in the anti-Nter sera. ECL1 and ECL2 antisera induced nearly complete long-lasting CCR5 downregulation of the receptor, and especially, their IgG-depleted fractions prevented HIV infection in neutralization and transcytosis assays. In conclusion, the ECL1 and ECL2 domains could offer a promising path to achieve significant anti-HIV activity in vivo. The study was the first to adopt a systematic strategy to compare the immunogenicities of all extracellular domains of the CCR5 molecule and to set optimal conditions leading to generation of specific antibodies in the mouse model. There were several relevant findings, which could be translated into human trials. (i) Prime (systemic) and boost (mucosal) immunization is the best protocol to induce anti-self antibodies with the expected properties. (ii) Aluminum is the best adjuvant in mice and thus can be easily used in nonhuman primates (NHP) and humans. (iii) The Flock House virus (FHV) system represents a valid delivery system, as the structure is well known and is not pathogenic for humans, and it is possible to introduce constrained regions able to elicit antibodies that recognize conformational epitopes. (iv) The best CCR5 vaccine candidate should include either extracellular loop 1 or 2 (ECL1 or ECL2), but not N terminus domains.
Project Orion, Environmental Control and Life Support System Integrated Studies
NASA Technical Reports Server (NTRS)
Russell, James F.; Lewis, John F.
2008-01-01
Orion is the next vehicle for human space travel. Humans will be sustained in space by the Orion subystem, environmental control and life support (ECLS). The ECLS concept at the subsystem level is outlined by function and technology. In the past two years, the interface definition with other subsystems has increased through different integrated studies. The paper presents the key requirements and discusses three recent studies (e.g., unpressurized cargo) along with the respective impacts on the ECLS design moving forward.
ERIC Educational Resources Information Center
Cornwell, Christopher; Mustard, David B.; Van Parys, Jessica
2013-01-01
Using data from the 1998-99 ECLS-K cohort, we show that the grades awarded by teachers are not aligned with test scores. Girls in every racial category outperform boys on reading tests, while boys score at least as well on math and science tests as girls. However, boys in all racial categories across all subject areas are not represented in…
Modeling and Analysis of Chill and Fill Processes for the EDU Tank
NASA Technical Reports Server (NTRS)
Hedayat, A.; Cartagena, W.; Majumdar, A. K.; Leclair, A. C.
2015-01-01
NASA's future missions may require long-term storage and transfer of cryogenic propellants. The Engineering Development Unit (EDU), a NASA in-house effort supported by both Marshall Space Flight Center (MSFC) and Glenn Research Center (GRC), is a Cryogenic Fluid Management (CFM) test article that primarily serves as a manufacturing pathfinder and a risk reduction task for a future CFM payload. The EDU test article, comprises a flight like tank, internal components, insulation, and attachment struts. The EDU is designed to perform integrated passive thermal control performance testing with liquid hydrogen in a space-like vacuum environment. A series of tests, with liquid hydrogen as a testing fluid, was conducted at Test Stand 300 at MSFC during summer of 2014. The objective of this effort was to develop a thermal/fluid model for evaluating the thermodynamic behavior of the EDU tank during the chill and fill processes. Generalized Fluid System Simulation Program (GFSSP), an MSFC in-house general-purpose computer program for flow network analysis, was utilized to model and simulate the chill and fill portion of the testing. The model contained the liquid hydrogen supply source, feed system, EDU tank, and vent system. The modeling description and comparison of model predictions with the test data will be presented in the final paper.
Fu, Xiaomin; Tan, Xingrong; Yuan, Ruo; Chen, Shihong
2017-04-15
A novel dual-potential ratiometric electrochemiluminescence (ECL) sensor was designed for detecting dopamine (DA) based on graphene-CdTe quantum dots (G-CdTe QDs) as the cathodic emitter and self-enhanced Ru(II) composite (TAEA-Ru) as the anodic emitter. TAEA-Ru was prepared by linking ruthenium(II) tris(2,2'-bipyridyl-4,4'-dicarboxylato) with tris(2-aminoethyl)amine. Firstly, 3-aminopropyltriethoxysilane founctionalized G-CdTe QDs was used as the substrate for capturing target DA via the specific recognition of the diol of DA to the oxyethyl group of APTES. Then, Cu 2 O nanocrystals supported TAEA-Ru was further bound by the strong interaction between amino groups of DA and carboxyl groups of the Cu 2 O-TAEA-Ru. With the increase in DA concentration, the loading of Cu 2 O-TAEA-Ru at the electrode increased. As a result, the anodic ECL signal from TAEA-Ru increased, and the cathodic ECL signal from G-CdTe QDs/O 2 system decreased correspondingly. Such a decrease was resulted from the ECL resonance energy transfer (RET) from G-CdTe QDs to TAEA-Ru as well as the dual quenching effects of Cu 2 O to G-CdTe QDs, namely the ECL-RET from G-CdTe QDs to Cu 2 O and the consumption of coreactant O 2 by Cu 2 O. Based on the ratio of two ECL signals, the determination of DA was achieved with a linear range from 10.0 fM to 1.0nM and a detection limit low to 2.9 fM (S/N=3). The combination of G-CdTe QDs/O 2 and TAEA-Ru would break the limitation of the same coreatant shared in previous ECL ratiometric systems and provide a potential application of ECL ratiometric sensor in the detection of biological small molecules with the assistance of the dual molecular recognition strategy. Copyright © 2016 Elsevier B.V. All rights reserved.
Extracorporeal Life Support for Severe Acute Respiratory Distress Syndrome in Adults
Hemmila, Mark R.; Rowe, Stephen A.; Boules, Tamer N.; Miskulin, Judiann; McGillicuddy, John W.; Schuerer, Douglas J.; Haft, Jonathan W.; Swaniker, Fresca; Arbabi, Saman; Hirschl, Ronald B.; Bartlett, Robert H.
2004-01-01
Objective: Severe acute respiratory distress syndrome (ARDS) is associated with a high level of mortality. Extracorporeal life support (ECLS) during severe ARDS maintains oxygen and carbon dioxide gas exchange while providing an optimal environment for recovery of pulmonary function. Since 1989, we have used a protocol-driven algorithm for treatment of severe ARDS, which includes the use of ECLS when standard therapy fails. The objective of this study was to evaluate our experience with ECLS in adult patients with severe ARDS with respect to mortality and morbidity. Methods: We reviewed our complete experience with ELCS in adults from January 1, 1989, through December 31, 2003. Severe ARDS was defined as acute onset pulmonary failure, with bilateral infiltrates on chest x-ray, and PaO2/fraction of inspired oxygen (FiO2) ratio ≤100 or A-aDO2 >600 mm Hg despite maximal ventilator settings. The indication for ECLS was acute severe ARDS unresponsive to optimal conventional treatment. The technique of ECLS included veno-venous or veno-arterial vascular access, lung “rest” at low FiO2 and inspiratory pressure, minimal anticoagulation, and optimization of systemic oxygen delivery. Results: During the study period, ECLS was used for 405 adult patients age 17 or older. Of these 405 patients, 255 were placed on ECLS for severe ARDS refractory to all other treatment. Sixty-seven percent were weaned off ECLS, and 52% survived to hospital discharge. Multivariate logistic regression analysis identified the following pre-ELCS variables as significant independent predictors of survival: (1) age (P = 0.01); (2) gender (P = 0.048); (3) pH ≤7.10 (P = 0.01); (4) PaO2/FiO2 ratio (P = 0.03); and (5) days of mechanical ventilation (P < 0.001). None of the patients who survived required permanent mechanical ventilation or supplemental oxygen therapy. Conclusion: Extracorporeal life support for severe ARDS in adults is a successful therapeutic option in those patients who do not respond to conventional mechanical ventilator strategies. PMID:15383787
Space Station Freedom Water Recovery test total organic carbon accountability
NASA Technical Reports Server (NTRS)
Davidson, Michael W.; Slivon, Laurence; Sheldon, Linda; Traweek, Mary
1991-01-01
Marshall Space Flight Center's (MSFC) Water Recovery Test (WRT) addresses the concept of integrated hygiene and potable reuse water recovery systems baselined for Space Station Freedom (SSF). To assess the adequacy of water recovery system designs and the conformance of reclaimed water quality to established specifications, MSFC has initiated an extensive water characterization program. MSFC's goal is to quantitatively account for a large percentage of organic compounds present in waste and reclaimed hygiene and potable waters from the WRT and in humidity condensate from Spacelab missions. The program is coordinated into Phase A and B. Phase A's focus is qualitative and semi-quantitative. Precise quantitative analyses are not emphasized. Phase B's focus centers on a near complete quantitative characterization of all water types. Technical approaches along with Phase A and partial Phase B investigations on the compositional analysis of Total Organic Carbon (TOC) Accountability are presented.
International Space Station (ISS)
2001-02-01
The Marshall Space Flight Center (MSFC) is responsible for designing and building the life support systems that will provide the crew of the International Space Station (ISS) a comfortable environment in which to live and work. Scientists and engineers at the MSFC are working together to provide the ISS with systems that are safe, efficient and cost-effective. These compact and powerful systems are collectively called the Environmental Control and Life Support Systems, or simply, ECLSS. This is an exterior view of the U.S. Laboratory Module Simulator containing the ECLSS Internal Thermal Control System (ITCS) testing facility at MSFC. At the bottom right is the data acquisition and control computers (in the blue equipment racks) that monitor the testing in the facility. The ITCS simulator facility duplicates the function, operation, and troubleshooting problems of the ITCS. The main function of the ITCS is to control the temperature of equipment and hardware installed in a typical ISS Payload Rack.
Nursing care for women with pre-eclampsia and/or eclampsia: integrative review.
Ferreira, Maria Beatriz Guimarães; Silveira, Caroline Freitas; Silva, Sueli Riul da; Souza, Delvane José de; Ruiz, Mariana Torreglosa
2016-04-01
To analyze the available evidence in the literature on nursing care for women with pre-eclampsia and/or eclampsia. Integrative review searching for primary studies in the databases PubMed, CINAHL, LILACS and SciELO. The sample size consisted of 17 primary studies published between January 2000 and December 2014, grouped into four categories: standardizing blood pressure measurement technique; training with simulation; instruments for standardization of care and quality of care The main nursing actions were: physical examination, early detection of signs of pre-eclampsia/eclampsia, monitoring of laboratory tests, fetal assessment, qualification and training of professionals. We identified the need for standardization of care from instruments, protocols and blood pressure measurement technique, early identification and treatment of hypertensive crisis through institutional protocols and review of cases and work processes. Women with pre-eclampsia and/or eclampsia require specific nursing care, which must be guided by care protocols based on scientific evidence. Analisar as evidências disponíveis na literatura sobre assistência de enfermagem às mulheres com pré-eclâmpsia e/ou eclâmpsia. Revisão integrativa cuja busca dos estudos primários foi realizada nas bases de dados PubMed, CINAHL, LILACS e SciELO. Amostra foi composta por 17 estudos primários, publicados entre janeiro de 2000 e dezembro de 2014, agrupados em quatro categorias: padronização da técnica de mensuração da pressão arterial; treinamentos com simulação; instrumentos para padronização da assistência e qualidade da assistência As principais ações de enfermagem foram: exame físico, identificação precoce de sinais de pré-eclâmpsia/eclâmpsia, acompanhamento de exames laboratoriais, avaliação fetal, capacitação e treinamento dos profissionais. Identificou-se a necessidade de padronização do atendimento a partir de instrumentos e protocolos e da técnica de aferição da pressão arterial, identificação e tratamento precoces da crise hipertensiva mediante protocolos institucionais e revisão de casos e processos de trabalho. Mulheres com pré-eclâmpsia e/ou eclâmpsia exigem cuidados de enfermagem específicos, os quais devem ser pautados em protocolos de cuidados baseados em evidências científicas.
1973-05-01
Sixty-three seconds after the launch of the modified Saturn V vehicle carrying the Skylab cluster, engineers in the operation support and control center saw an unexpected telemetry indication that signalled that damages occurred on one solar array and the micrometeoroid shield during the launch. Still unoccupied, the Skylab was stricken with the loss of the heat shield and sunlight beat mercilessly on the lab's sensitive skin. Internal temperatures soared, rendering the the station uninhabitable, threatening foods, medicines, films, and experiments. The launch of the first marned Skylab (Skylab-2) mission was delayed until methods were devised to repair and salvage the workshop. Personnel from other NASA Centers and industries quickly joined the Marshall Space Flight Center (MSFC) in efforts to save the damaged Skylab. They worked day and night for the next several days. Eventually the MSFC developed, tested, rehearsed, and approved three repair options. These options included a parasol sunshade and a twin-pole sunshade to restore the temperature inside the workshop, and a set of metal cutting tools to free the jammed solar panel. This photograph was taken during a discussion of the methods of the twin-pole Sun shield by (left to right) Astronaut Alan Bean, MSFC Director Dr. Rocco Petrone, Astronaut Edward Gibson, and MSFC engineer Richard Heckman. Dr. William Lucas, who became MSFC Director after Dr. Petrone left MSFC in March of 1974, is standing.
Space Station propulsion - Advanced development testing of the water electrolysis concept at MSFC
NASA Technical Reports Server (NTRS)
Jones, Lee W.; Bagdigian, Deborah R.
1989-01-01
The successful demonstration at Marshall Space Flight Center (MSFC) that the water electrolysis concept is sufficiently mature to warrant adopting it as the baseline propulsion design for Space Station Freedom is described. In particular, the test results demonstrated that oxygen/hydrogen thruster, using gaseous propellants, can deliver more than two million lbf-seconds of total impulse at mixture ratios of 3:1 to 8:1 without significant degradation. The results alao demonstrated succcessful end-to-end operation of an integrated water electrolysis propulsion system.
Clinical aspects of ECL-cell abnormalities.
Hirschowitz, B. I.
1998-01-01
ECL cell hyperplasia results from hypergastrinemia, and in man this occurs due to achlorhydria in atrophic gastritis (pernicious anemia [PA]) and gastrinoma (Zollinger-Ellison syndrome [ZES]). Progression to neoplasia, i.e., ECL cell carcinoids (usually small, multicentric and non-functional), occurs in some five to 10 percent of patients with PA where they remain gastrin-dependent and reversible by normalization of serum gastrin by antrectomy. Even if untreated, the carcinoids are almost invariably benign and do not cause death. In ZES, ECL cell hyperplasia is progressive due to hypergastrinemia. However, carcinoids develop only in the MEN-I subtype but pose no additional threat of malignancy. A conservative approach is recommended for small multicentric carcinoids, and the tumors do not need removal. By contrast, single, large, non-gastrin-dependent carcinoids represent a different biological and clinical problem and are frequently malignant. PMID:10461361
An electrochemiluminescence biosensor for endonuclease EcoRI detection.
Li, Yingjie; Li, Yuqin; Wu, Yaoyu; Lu, Fushen; Chen, Yaowen; Gao, Wenhua
2017-03-15
Endonucleases cleavage of DNA plays an important role in biological and medicinal chemistry. This work was going to develop a reliable and sensitive electrochemiluminescent (ECL) biosensor for detecting endonucleases by using gold nanoparticles graphene composite (GNPs-graphene) as a signal amplifier. Firstly, the GNPs and graphene were simultaneously deposited on the glassy carbon electrode (GCE) by cyclic voltammetry. Then a stem DNA was anchored on the surface of GCE. And with a modifying DNA introduced into the electrode by DNA assembly, a strong ECL signal was obtained. After a DNA modified with ferrocene assembly to the stem DNA, the ECL signal had a sharp decrease due to the quench effect of ferrocene to and the biosensor comes into being a "off" state. With the effect of endonuclease, the ECL signal had a recovery because of the ferrocene being released and the biosensor formed a "on" state. Moreover, the recovery of ECL signal was related to the concentration of endonucleases. Combining specific defined DNA and endonuclease, this method has a potential to detect different endonucleases. In this work, we took the EcoRI as an example to identify the feasibility of ECL biosensor in applying in sensitive detection of endonucleases using a GNPs-graphene signal amplifier. Under optimal condition, the proposed biosensor obtained a low limit of detection (LOD) 5.6×10 -5 UmL -1 . And the stability, selectivity and reproducibility of the biosensor also were researched. Copyright © 2016 Elsevier B.V. All rights reserved.
Gao, Hongfei; Wen, Luke; Wu, Yuhua; Fu, Zhifeng; Wu, Gang
2017-11-15
The development of genetically modified (GM) insect-resistant crops has aroused great public concern about the risks on the eco-environment resulting from a release of toxic Cry proteins (such as Cry1Ab) to the soil. Therefore, it is of crucial importance to measure the Cry proteins level and the GM crops content. Here, we have tested for the first time a method that uses novel carbon nanospheres (CNPs) label-free electrochemiluminescent (ECL) immunosensor for the ultrasensitive quantification of Cry1Ab and GM crops. In this work, novel CNPs were prepared from printer toner with a very facile approach, and linked with anti-Cry1Ab antibodies to modify a golden working electrode. The immunoreaction between Cry1Ab and its antibody formed an immunocomplex on the bioreceptor region of the sensor, which inhibited electron transfer between the electrode surface and the ECL substance, leading to a decrease of ECL response. Under the optimal conditions, the fabricated label-free ECL immunosensor determined Cry1Ab down to 3.0pgmL -1 within a linear range of 0.010-1.0ngmL -1 , showing significant improvement of sensitivity than that of most previous reports. Meanwhile, the proposed method was successfully applied for GM rice BT63 and GM maize MON810 detections down to 0.010% and 0.020%, respectively. Due to its outstanding advantages such as high sensitivity, ideal selectivity, simple fabrication, rapid detection, and low cost, the developed method can be considered as a powerful and pioneering tool for GM crops detection. Its use can also be extended to other toxin protein sensing in foods. Copyright © 2017. Published by Elsevier B.V.
Crew Exploration Vehicle Environmental Control and Life Support Development Status
NASA Technical Reports Server (NTRS)
Lewis, John F.; Barido, Richard A.; Cross, Cynthia D.; Carrasquillo, Robyn; Rains, George Edward
2011-01-01
The Orion Crew Exploration Vehicle (CEV) is the first crew transport vehicle to be developed by the National Aeronautics and Space Administration (NASA) in the last thirty years. The CEV is currently being developed to transport the crew safely from the Earth to the Moon and back again. This year, the vehicle focused on building the Orion Flight Test 1 (OFT1) vehicle to be launched in 2013. The development of the Orion Environmental Control and Life Support (ECLS) System, focused on the components which are on OFT1 which includes pressure control and active thermal control systems, is progressing through the design stage into manufacturing. Additional development work was done to keep the remaining component progressing towards implementation. This paper covers the Orion ECLS development from April 2010 to April 2011.
X-Ray Testing Constellation-X Optics at MSFC's 100-m Facility
NASA Technical Reports Server (NTRS)
O'Dell, Stephen; Baker, Markus; Content, David; Freeman, Mark; Glenn, Paul; Gubarev, Mikhail; Hair, Jason; Jones, William; Joy, Marshall
2003-01-01
In addition to the 530-m-long X-Ray Calibration Facility (XRCF), NASA's Marshall Space Flight Center (MSFC) operates a 104-m-long (source-to-detector) X-ray-test facility. Originally developed and still occasionally used for stray-light testing of visible-fight optical systems, the so-called "Stray-Light Facility" now serves primarily as a convenient and inexpensive facility for performance evaluation and calibration of X-ray optics and detectors. The facility can accommodate X-ray optics up to about 1-m diameter and 12-m focal length. Currently available electron-impact sources at the facility span the approximate energy range 0.2 to 100 keV, thus supporting testing of soft- and hard-X-ray optics and detectors. Available MSFC detectors are a front-illuminated CCD (charge-coupled device) and a scanning CZT (cadmium--zinc--telluride) detector, with low-energy cut-offs of about 0.8 and 3 keV, respectively. In order to test developmental optics for the Constellation-X Project, led by NASA's Goddard Space Flight Center (GSFC), MSFC undertook several enhancements to the facility. Foremost among these was development and fabrication of a five-degree-of-freedom (5-DoF) optics mount and control system, which translates and tilts the user-provided mirror assembly suspended from its interface plate. Initial Constellation-X tests characterize the performance of the Optical Alignment Pathfinder Two (OAP2) for the large Spectroscopy X-ray Telescope (SXT) and of demonstration mirror assemblies for the Hard X-ray Telescope (HXT). With the Centroid Detector Assembly (CDA), used for precision alignment of the Chandra (nee AXAF) mirrors, the Constellation-X SXT Team optically aligned the individual mirrors of the OAPZ at GSFC. The team then developed set-up and alignment procedures, including transfer of the alignment from the optical alignment facility at GSFC to the X-ray test facility at MSFC, using a reference flat and fiducials. The OAPZ incorporates additional ancillary features --- fixed aperture mask and movable sub-aperture mask --- to facilitate X-ray characterization of the optics. Although the OAPZ was designed to- have low sensitivity to temperature offsets and gradients, analyses showed the necessity of active temperature control for the X-ray performance testing. Thus, the Smithsonian Astrophysical Observatory (SAO) implemented a thermal control and monitoring system, designed to hold the OAP2 close to its assembly.
NASA Technical Reports Server (NTRS)
Wiegmann, Bruce M.; Hovater, Mary; Kos, Larry
2012-01-01
NASA/MSFC has been investigating the various aspects of the growing orbital debris problem since early 2009. Data shows that debris ranging in size from 5 mm to 10 cm presents the greatest threat to operational spacecraft today. Therefore, MSFC has focused its efforts on small orbital debris. Using off-the-shelf analysis packages, like the ESA MASTER software, analysts at MSFC have begun to characterize the small debris environment in LEO to support several spacecraft concept studies and hardware test programs addressing the characterization, mitigation, and ultimate removal, if necessary, of small debris. The Small Orbital Debris Active Removal (SODAR) architectural study investigated the overall effectiveness of removing small orbital debris from LEO using a low power, space-based laser. The Small Orbital Debris Detection, Acquisition, and Tracking (SODDAT) conceptual technology demonstration spacecraft was developed to address the challenges of in-situ small orbital debris environment classification including debris observability and instrument requirements for small debris observation. Work is underway at MSFC in the areas of hardware and testing. By combining off the shelf digital video technology, telescope lenses, and advanced video image FPGA processing, MSFC is building a breadboard of a space based, passive orbital tracking camera that can detect and track faint objects (including small debris, satellites, rocket bodies, and NEOs) at ranges of tens to hundreds of kilometers and speeds in excess of 15 km/sec,. MSFC is also sponsoring the development of a one-of-a-kind Dynamic Star Field Simulator with a high resolution large monochrome display and a custom collimator capable of projecting realistic star images with simple orbital debris spots (down to star magnitude 11-12) into a passive orbital detection and tracking system with simulated real-time angular motions of the vehicle mounted sensor. The dynamic star field simulator can be expanded for multiple sensors (including advanced star trackers), real-time vehicle pointing inputs, and more complex orbital debris images. This system is also adaptable to other sensor optics, missions, and installed sensor testing.
Guenther, Sabina; Theiss, Hans D; Fischer, Matthias; Sattler, Stefan; Peterss, Sven; Born, Frank; Pichlmaier, Maximilian; Massberg, Steffen; Hagl, Christian; Khaladj, Nawid
2014-03-01
Therapy refractory cardiogenic shock is associated with dismal outcome. Percutaneous implantation of an extracorporeal life support (ECLS) system achieves immediate cardiopulmonary stabilization, sufficient end-organ perfusion and reduction of subsequent multiorgan failure (MOF). Forty-one patients undergoing percutaneous ECLS implantation for cardiogenic shock from February 2012 until August 2013 were retrospectively analysed. Mean age was 52 ± 13 years, 6 (15%) were female. Mean pH values obtained before ECLS implantation were 7.15 ± 0.24, mean lactate concentration was 11.7 ± 6.4 mmol/l. Levels obtained 6 h after ECLS implantation were 7.30 ± 0.14 and 8.7 ± 5.0 mmol/l, respectively. In 23 patients (56%) cardiogenic shock resulted from an acute coronary syndrome in 13 (32%) from cardiomyopathy, in 5 (12%) from other causes. Twenty-seven (66%) had been resuscitated, in 14 (34%) implantation was performed under ongoing cardiopulmonary resuscitation (CPR). Of note, 97% of the acute coronary syndrome patients underwent percutaneous coronary intervention (PCI) either before ECLS implantation or under ECLS support. Extracorporeal life support implantation was performed on scene (Emergency Department, Cath Lab, Intensive Care Unit) by a senior cardiac surgeon and a trained perfusionist, in 8 cases (20%) in the referring hospital. Thirty-day mortality was 51% [21 patients, due to MOF (n = 14), cerebral complications (n = 6) and heart failure (n = 1)]. Logistic regression analysis identified 6-h pH values as an independent risk factor of 30-day mortality (P < 0.001, OR = 0.000, 95% CI 0.000-0.042). Neither CPR nor implantation under ongoing CPR resulted in significant differences. In 26 cases (63%), the ECLS system could be explanted, after mean support of 169 ± 67 h. Seven of these patients received cardiac surgery [ventricular assist device implantation (n = 4), heart transplantation (n = 1), other procedures (n = 2)]. Due to the evolution of transportable ECLS systems and percutaneous techniques implantation on scene is feasible. Extracorporeal life support may serve as a bridge-to-decision and bridge-to-treatment device. Neurological evaluation before ventricular assist device implantation and PCI under stable conditions are possible. Despite substantial mortality, ECLS implantation in selected patients by an experienced team offers additional support to conventional therapy as well as CPR and allows survival in patients that otherwise most likely would have died. This concept has to be implemented in cardiac survival networks in the future.
Shelton, Daniel R; Van Kessel, Jo Ann S; Wachtel, Marian R; Belt, Kenneth T; Karns, Jeffrey S
2003-12-01
We report here the use of immunomagnetic (IM) electrochemiluminescence (ECL) for quantitative detection of Esherichia coli O157:H7 in water samples following enrichment in minimal lactose broth (MLB). IM beads prepared in-house with four commercial anti-O157 monoclonal antibodies were compared for efficiency of cell capture. IM-ECL responses for E. coli O157:H7 (strain SEA13B88) were similar for all four commercial anti-O157 LPS monoclonal antibodies. The ECL signal was linearly correlated with E. coli O157:H7 cell concentration, indicating a constant ECL response per cell. Twenty-two strains of E. coli O157:H7 or O157:NM gave comparable ECL signals using IM beads prepared in-house. To assess the potential for interference from background bacteria in MLB-enriched water samples, 10(4) cells of E. coli O157:H7 (strain SEA13B88) were added to enriched samples prior to analysis. There was considerable variability in recovery of E. coli O157:H7 cells; net ECL signals ranged from 1% to 100% of expected values (i.e., percent inhibition from 0% to 99%). Cultures of Klebsiella pneumoniae, Klebsiella oxytoca, and Enterobacter cloacae, subsequently isolated from MLB-enriched water samples via IM separation (IMS), were observed to interfere with the binding of E. coli O157:H7 cells to IM beads. Recoveries of 10(4) E. coli O157:H7 cells were =10% in the presence of ca. 10(8) K. pneumoniae, K. oxytoca, or E. cloacae cells. None of these strains gave a positive IM-ECL signal. Although competitive binding decreased sensitivity, there still was a linear correlation between ECL signal and higher E. coli O157:H7 cell concentrations. These studies indicate that IM-ECL in conjunction with MLB enrichment is capable of quantitatively detecting as few as 10(3) to 10(5) E. coli O157:H7 cells ml(-1), depending on percent recoveries, in enriched samples that contain ca. 10(9) total lactose-fermenting bacteria ml(-1). Assuming comparable growth rates for E. coli O157:H7 and other lactose-fermenting bacteria in MLB, it may be possible to detect as few as one E. coli O157:H7 in 100 ml of raw water containing as many as 10(4) to 10(6) lactose-fermenting bacteria (i.e., total coliforms).
X-Ray Optics at NASA Marshall Space Flight Center
NASA Technical Reports Server (NTRS)
O'Dell, Stephen L.; Atkins, Carolyn; Broadway, David M.; Elsner, Ronald F.; Gaskin, Jessica A.; Gubarev, Mikhail V.; Kilaru, Kiranmayee; Kolodziejczak, Jeffery J.; Ramsey, Brian D.; Roche, Jacqueline M.;
2015-01-01
NASA's Marshall Space Flight Center (MSFC) engages in research, development, design, fabrication, coating, assembly, and testing of grazing-incidence optics (primarily) for x-ray telescope systems. Over the past two decades, MSFC has refined processes for electroformed-nickel replication of grazing-incidence optics, in order to produce high-strength, thin-walled, full-cylinder x-ray mirrors. In recent years, MSFC has used this technology to fabricate numerous x-ray mirror assemblies for several flight (balloon, rocket, and satellite) programs. Additionally, MSFC has demonstrated the suitability of this technology for ground-based laboratory applications-namely, x-ray microscopes and cold-neutron microscopes and concentrators. This mature technology enables the production, at moderately low cost, of reasonably lightweight x-ray telescopes with good (15-30 arcsecond) angular resolution. However, achieving arcsecond imaging for a lightweight x-ray telescope likely requires development of other technologies. Accordingly, MSFC is conducting a multi-faceted research program toward enabling cost-effective production of lightweight high-resolution x-ray mirror assemblies. Relevant research topics currently under investigation include differential deposition for post-fabrication figure correction, in-situ monitoring and control of coating stress, and direct fabrication of thin-walled full-cylinder grazing-incidence mirrors.
Chen, Anyi; Gui, Guo-Feng; Zhuo, Ying; Chai, Ya-Qin; Xiang, Yun; Yuan, Ruo
2015-06-16
A target induced cycling strand displacement amplification (SDA) mediated by phi29 DNA polymerase (phi29) was first investigated and applied in a signal-off electrochemiluminescence (ECL) biosensor for microRNA (miRNA) detection. Herein, the target miRNA triggered the phi29-mediated SDA which could produce amounts of single-stranded DNA (assistant probe) with accurate and comprehensive nucleotide sequence. Then, the assistant probe hybridized with the capture probe and the ferrocene-labeled probe (Fc-probe) to form a ternary "Y" structure for ECL signal quenching by ferrocene. Therefore, the ECL intensity would decrease with increasing concentration of the target miRNA, and the sensitivity of biosensor would be promoted on account of the efficient signal amplification of the target induced cycling reaction. Besides, a self-enhanced Ru(II) ECL system was designed to obtain a stable and strong initial signal to further improve the sensitivity. The ECL assay for miRNA-21 detection is developed with excellent sensitivity of a concentration variation from 10 aM to 1.0 pM and limit of detection down to 3.3 aM.
Vorre, P; Illum, P; Oster, S; Reske-Nielsen, E; Larsen, K B
1989-01-01
In 6 pigs a bronchoscopical resection of the tracheal mucosa was performed using CO2-laser on one side, and an electric high-frequency cutting loop (ECL) on the other. The pigs were sacrificed 3 months later. On macroscopic examination the tracheal mucosa appeared almost normal on the laser-resected side, while severe deformation was seen after ECL treatment. Microscopically the respiratory epithelium had regenerated irrespective of the instrument used. After laser resection the subepithelial tissue had a normal width and consisted of collagen fibrils with few vessels and sparse fragmented elastic tissue. The cartilage showed necrosis and pericellular fibrosis. The scar tissue after ECL was a broad cellular and richly vascularized connective tissue. The content of elastic fibres was markedly greater than after laser resection. The cartilage showed small irregular necroses lined by pyknotic nuclei. In neither case had the gland regenerated. Both CO2-laser and ECL caused severe (but not identical) damage to the tissue, clearly visible after 3 months. However, the deformation caused by ECL was not seen at the laser-resected sites, which makes the laser technique seem preferable--where economy permits.
A new verification film system for routine quality control of radiation fields: Kodak EC-L.
Hermann, A; Bratengeier, K; Priske, A; Flentje, M
2000-06-01
The use of modern irradiation techniques requires better verification films for determining set-up deviations and patient movements during the course of radiation treatment. This is an investigation of the image quality and time requirement of a new verification film system compared to a conventional portal film system. For conventional verifications we used Agfa Curix HT 1000 films which were compared to the new Kodak EC-L film system. 344 Agfa Curix HT 1000 and 381 Kodak EC-L portal films of different tumor sites (prostate, rectum, head and neck) were visually judged on a light box by 2 experienced physicians. Subjective judgement of image quality, masking of films and time requirement were checked. In this investigation 68% of 175 Kodak EC-L ap/pa-films were judged "good", only 18% were classified "moderate" or "poor" 14%, but only 22% of 173 conventional ap/pa verification films (Agfa Curix HT 1000) were judged to be "good". The image quality, detail perception and time required for film inspection of the new Kodak EC-L film system was significantly improved when compared with standard portal films. They could be read more accurately and the detection of set-up deviation was facilitated.
Zhao, Jing; Lei, Yan-Mei; Chai, Ya-Qin; Yuan, Ruo; Zhuo, Ying
2016-12-15
In this paper, a novel covalently crosslinked perylene derivative (PTC-PEI) composed of polyethylenimine (PEI) and perylenetetracarboxylic acid (PTCA) has been first investigated for cathodic electrochemiluminescence (ECL) in an aqueous system with dissolved O2 as coreactant. The promising novel ECL materials of PTC-PEI exhibited admirable physical and chemical stability and high ECL intensity, which held an alternative way to construct ECL sensor with improved sensitivity. Thus, it was applied to construct a dual amplified "signal-on" mercury ion (Hg(2+)) sensor by the employment of nicking endonuclease (NEase)-assisted target recycling and rolling circle amplification (RCA) for signal amplification. Herein, a long G-rich sequence was generated by RCA process to capture abundant hemin on the electrode surface, and then a significantly amplified ECL signal of PTC-PEI was obtained. Based on dual signal amplification strategy, the devised sensor showed a linear range from 0.1pM to 0.1μΜ with a detection limit down to 33fM (S/N=3), and was successfully used in the direct detection of real water sample with high sensitivity and selectivity. Copyright © 2016 Elsevier B.V. All rights reserved.
Chen, Ying; Mao, Jianfei; Liu, Chunhua; Yuan, Hongyan; Xiao, Dan; Choi, Martin M F
2009-01-20
In this work, solid-state tris(4,7-diphenyl-1,10-phenanthroline) ruthenium(II) ditetrakis(4-chlorophenyl)borate ([Ru(dpp)(3)][(4-Clph)(4)B](2)) nanoislands are assembled spontaneously and simultaneously on an indium-doped tin oxide (ITO) glass electrode surface via a facile dewetting procedure. The fabrication process is very simple and also amenable to mass production. The as-prepared ruthenium complex nanoislands exhibit useful properties. The electrode is more electrochemically active and can produce strong, stable, reproducible solid-state electrochemiluminescence (ECL) signals using oxalate as the coreactant. The self-assembled nanoislands exhibit semiconductor-like broad, red-shift ECL spectrum. More importantly, they extend the application of the ruthenium complex ECL system from the usual alkaline to acidic conditions. The pH turn-off behavior of the ECL is observed for the first time and can serve as an ultrasensitive pH sensor around physiological pH 7.0. The solid-state [Ru(dpp)(3)][(4-Clph)(4)B](2) ECL signal is efficiently inhibited by phenol even at a very low concentration (i.e., 20 nM), thus providing the potential for the determination of phenolic compounds in practical applications.
NASA Astrophysics Data System (ADS)
Ok, Jung-Woo; Pooyodying, Pattarapon; Anuntahirunrat, Jirapat; Sung, Youl-Moon
2018-04-01
In this paper, we investigate electrochemical luminescent (ECL) device with a new structure and the ECL cell device with proposed electrode configuration works reliably at AC voltage. In particular, the conventional ECL cell has counter electrodes in which a cathode and an anode are opposed to each other, whereas the proposed structure has parallel electrodes in which a cathode and an anode are arranged on a single substrate. The proposed electrode configuration has a structural feature that electric short-circuiting is less likely to occur during bending than the conventional electrode configuration. The electro-optical characteristics of the new electrode configuration such as the current density, the light emission intensity, and the time evolution of the emission are investigated. The proposed ECL device exhibited higher light emitting efficiency than the conventional structure. Especially, at AC operation mode, the new structure showed the distinctive luminescence characteristic which is combined the first luminescence near the surface of electrode with the delayed second luminescence near the center of between electrodes. It was closely related to the behavior of luminescent particles. The proposed the ECL cell structure is expected to be utilized as a flexible display device by taking advantage of its characteristics and practicality.
Southern Impact Testing Alliance (SITA)
NASA Technical Reports Server (NTRS)
Hubbs, Whitney; Roebuck, Brian; Zwiener, Mark; Wells, Brian
2009-01-01
Efforts to form this Alliance began in 2008 to showcase the impact testing capabilities within the southern United States. Impact testing customers can utilize SITA partner capabilities to provide supporting data during all program phases-materials/component/ flight hardware design, development, and qualification. This approach would allow programs to reduce risk by providing low cost testing during early development to flush out possible problems before moving on to larger scale1 higher cost testing. Various SITA partners would participate in impact testing depending on program phase-materials characterization, component/subsystem characterization, full-scale system testing for qualification. SITA partners would collaborate with the customer to develop an integrated test approach during early program phases. Modeling and analysis validation can start with small-scale testing to ensure a level of confidence for the next step large or full-scale conclusive test shots. Impact Testing Facility (ITF) was established and began its research in spacecraft debris shielding in the early 1960's and played a malor role in the International Space Station debris shield development. As a result of return to flight testing after the loss of STS-107 (Columbia) MSFC ITF realized the need to expand their capabilities beyond meteoroid and space debris impact testing. MSFC partnered with the Department of Defense and academic institutions as collaborative efforts to gain and share knowledge that would benefit the Space Agency as well as the DoD. MSFC ITF current capabilities include: Hypervelocity impact testing, ballistic impact testing, and environmental impact testing.
Fast Paced, Low Cost Projects at MSFC
NASA Technical Reports Server (NTRS)
Watson-Morgan, Lisa; Clinton, Raymond
2012-01-01
What does an orbiting microsatellite, a robotic lander and a ruggedized camera and telescope have in common? They are all fast paced, low cost projects managed by Marshall Space Flight Center (MSFC) teamed with successful industry partners. MSFC has long been synonymous with human space flight large propulsion programs, engineering acumen and risk intolerance. However, there is a growing portfolio/product line within MSFC that focuses on these smaller, fast paced projects. While launching anything into space is expensive, using a managed risk posture, holding to schedule and keeping costs low by stopping at egood enough f were key elements to their success. Risk is defined as the possibility of loss or failure per Merriam Webster. The National Aeronautics and Space Administration (NASA) defines risk using procedural requirement 8705.4 and establishes eclasses f to discern the acceptable risk per a project. It states a Class D risk has a medium to significant risk of not achieving mission success. MSFC, along with industry partners, has created a niche in Class D efforts. How did the big, cautious MSFC succeed on these projects that embodied the antithesis of its heritage in human space flight? A key factor toward these successful projects was innovative industry partners such as Dynetics Corporation, University of Alabama in Huntsville (UAHuntsville), Johns Hopkins Applied Physics Laboratory (JHU APL), Teledyne Brown Engineering (TBE), Von Braun Center for Science and Innovation (VCSI), SAIC, and Jacobs. Fast Affordable Satellite Technology (FastSat HSV01) is a low earth orbit microsatellite that houses six instruments with the primary scientific objective of earth observation and technology demonstration. The team was comprised of Dynetics, UAHuntsvile, SAIC, Goddard Space Flight Center (GSFC) and VCSI with the United States Air Force Space Test Program as the customer. The team completed design, development, manufacturing, environmental test and integration in one year. FastSat HSV01 also deployed a Poly Picosatellite Orbital Deployer (PPOD) for a separate nano ]satellite class spacecraft (Cubesat: Nano Sail Demonstration) in partnership with Ames Research Center. The Robotic lunar lander is a MSFC JHU APL partnership that led to the development of a flexible architecture for landers to support robotic missions to a wide range of lunar and asteroid destinations. The team started with the goal of meeting NASA agency directives that led to the creation of a test bed focusing on GN&C and software to demonstrate the descent and landing on any airless body for the final 30 to 60 meters. The team created a complex technology demonstration as well as Guidance Control and Navigation (GN&C) algorithms providing autonomous control of the lander. The team uses a green propellant of 90% hydrogen peroxide and has completed 18 successful test flights. The International Space Station (ISS) SERVIR Environmental Research and Visualization System (ISERV) is a technology demonstration payload to assist the SERVIR project with environmental monitoring for disaster relief and humanitarian efforts. The ISERV project was a partnership with TBE. The ISERV payload consists of a commercial off the shelf camera, telescope, and MSFC developed power distribution box and interfaces on ISS with the Window Observational Research Facility in the US Lab. MSFC has identified three key areas that enabled the low cost mission success to include culture, partnering, and cost/schedule control. This paper will briefly discuss these three Class D efforts, FastSat HSV-01, the Robotic Lunar Lander and the ISERV camera system, the lessons learned, their successes and challenges.
Thermal performance of MSFC hot air collectors under natural and simulated conditions
NASA Technical Reports Server (NTRS)
Shih, K., Sr.
1977-01-01
The procedures used and the results obtained from an evaluation test program conducted to determine the thermal performance and structural characteristics of selected MSFC--designed hot air collectors under both real and simulated environmental conditions are described. Five collectors were tested in the three phased program. A series of outdoor tests were conducted to determine stagnation temperatures on a typical bright day and to determine each collector's ability to withstand these temperatures. Two of the collectors experienced structural deformation sufficient to eliminate them from the remainder of the test program. A series of outdoor tests to evaluate the thermal performance of collector S/N 10 under certain test conditions were performed followed by a series of indoor tests to evaluate the thermal performance of the collector under closely controlled simulated conditions.
Ouweneel, Dagmar M; Schotborgh, Jasper V; Limpens, Jacqueline; Sjauw, Krischan D; Engström, A E; Lagrand, Wim K; Cherpanath, Thomas G V; Driessen, Antoine H G; de Mol, Bas A J M; Henriques, José P S
2016-12-01
Veno-arterial extracorporeal life support (ECLS) is increasingly used in patients during cardiac arrest and cardiogenic shock, to support both cardiac and pulmonary function. We performed a systematic review and meta-analysis of cohort studies comparing mortality in patients treated with and without ECLS support in the setting of refractory cardiac arrest and cardiogenic shock complicating acute myocardial infarction. We systematically searched MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials and the publisher subset of PubMed updated to December 2015. Thirteen studies were included of which nine included cardiac arrest patients (n = 3098) and four included patients with cardiogenic shock after acute myocardial infarction (n = 235). Data were pooled by a Mantel-Haenzel random effects model and heterogeneity was examined by the I 2 statistic. In cardiac arrest, the use of ECLS was associated with an absolute increase of 30 days survival of 13 % compared with patients in which ECLS was not used [95 % CI 6-20 %; p < 0.001; number needed to treat (NNT) 7.7] and a higher rate of favourable neurological outcome at 30 days (absolute risk difference 14 %; 95 % CI 7-20 %; p < 0.0001; NNT 7.1). Propensity matched analysis, including 5 studies and 438 patients (219 in both groups), showed similar results. In cardiogenic shock, ECLS showed a 33 % higher 30-day survival compared with IABP (95 % CI, 14-52 %; p < 0.001; NNT 13) but no difference when compared with TandemHeart/Impella (-3 %; 95 % CI -21 to 14 %; p = 0.70; NNH 33). In cardiac arrest, the use of ECLS was associated with an increased survival rate as well as an increase in favourable neurological outcome. In the setting of cardiogenic shock there was an increased survival with ECLS compared with IABP.
Chen, Wanlu; Yao, Xun; Zhou, Xinchun; Zhao, Kang; Deng, Anping; Li, Jianguo
2018-05-01
A flower-like Au/Cu alloy nanocomposite (Au/Cu NFs) was synthesized and used in an electrochemiluminescence (ECL) based method for sensitive determination of the dye Sudan I. The Au-g-C 3 N 4 nanosheets as an ECL emitter were prepared by electrostatic adsorption between gold nanoparticles and g-C 3 N 4 . They form a film on a glassy carbon electrode (GCE) and then can be connected with Sudan I antigen via gold-nitrogen bond and amidation reactions. The Au/Cu NFs combined with Sudan I antibody also via the Au-N bond and was introduced into the modified GCE by specific recognition between the antibody and the antigen. The overlap between emission spectra of the Au-g-C 3 N 4 nanosheets and absorption spectra of Au/Cu NFs enabled the appearance of ECL resonance energy transfer process. That is, when the Sudan I analyte not present, the ECL was weakened due to absorption by the gray Au/Cu NFs on applying voltages from -1.7 V to 0 V. Conversely, the Au/Cu NFs on the GCE are reduced due to the competition for the antibody between the analyte and the antigen. A strong green ECL emission was obtained. The ECL response is linear in the 0.5 pg mL -1 to 100 ng mL -1 Sudan I concentration range, and the detection limit is 0.17 pg mL -1 . Graphical abstract An Au/Cu alloy flower-like nanocomposite (Au/Cu NFs) is firstly synthesized as an acceptor to constitute an electrochemiluminescence-resonance energy transfer (ECL-RET) system for sensitive measurement of Sudan I, while Au nanoparticles (Au NPs) functionalized graphitic carbon nitride (g-C 3 N 4 ) acted as a donor.
Cold Flow Plume Entrainment Test Final Report NTF Test Number 2456
NASA Technical Reports Server (NTRS)
Ruf, Joseph H.; McDaniels, David; Mishtawy, Jason; Ramachandran, Narayanan; Hammad, Khaled J.
2005-01-01
As part of the Space Shuttle Return to Flight (RTF) program, Marshall Space Flight Center (MSFC) performed computational fluid dynamics (CFD) analysis to define the velocity flowfields around the Shuttle stack at liftoff. These CFD predicted velocity flowfields were used in debris transport analysis (DTA). High speed flows such as plumes induce or 'entrain' mass from the surrounding environment. Previous work had shown that CFD analysis over-predicts plume induced flows. Therefore, the DTA would tend to 1) predict more debris impacts, and 2) the debris velocity (and kinetic energy) of those impacts would be too high. At a November, 2004 peer-review it was recommended that the Liftoff DTA team quantify the uncertainty in the DTA caused by the CFD's over prediction of plume induced flow. To do so, the Liftoff DTA team needed benchmark quality data for plume induced flow to quantify the CFD accuracy and its effect on the DTA. MSFC's Nozzle Test Facility (NTF) conducted the "Nozzle Induced Flows test, P#2456" to obtain experimental data for plume induced flows for nozzle flow exhausting into q quiescent freestream. Planning for the test began in December, 2004 and the experimental data was obtained in February and March of 2005. The funding for this test was provided by MSFC's Space Shuttle Propulsion Systems Integration and Engineering office.
3D-printed supercapacitor-powered electrochemiluminescent protein immunoarray.
Kadimisetty, Karteek; Mosa, Islam M; Malla, Spundana; Satterwhite-Warden, Jennifer E; Kuhns, Tyler M; Faria, Ronaldo C; Lee, Norman H; Rusling, James F
2016-03-15
Herein we report a low cost, sensitive, supercapacitor-powered electrochemiluminescent (ECL) protein immunoarray fabricated by an inexpensive 3-dimensional (3D) printer. The immunosensor detects three cancer biomarker proteins in serum within 35 min. The 3D-printed device employs hand screen printed carbon sensors with gravity flow for sample/reagent delivery and washing. Prostate cancer biomarker proteins, prostate specific antigen (PSA), prostate specific membrane antigen (PSMA) and platelet factor-4 (PF-4) in serum were captured on the antibody-coated carbon sensors followed by delivery of detection-antibody-coated Ru(bpy)3(2+) (RuBPY)-doped silica nanoparticles in a sandwich immunoassay. ECL light was initiated from RuBPY in the silica nanoparticles by electrochemical oxidation with tripropylamine (TPrA) co-reactant using supercapacitor power and ECL was captured with a CCD camera. The supercapacitor was rapidly photo-recharged between assays using an inexpensive solar cell. Detection limits were 300-500f gmL(-1) for the 3 proteins in undiluted calf serum. Assays of 6 prostate cancer patient serum samples gave good correlation with conventional single protein ELISAs. This technology could provide sensitive onsite cancer diagnostic tests in resource-limited settings with the need for only moderate-level training. Copyright © 2015 Elsevier B.V. All rights reserved.
NGST/XRCF Design and Build Wavescope System Pallet
NASA Technical Reports Server (NTRS)
Geary, Joe
1999-01-01
Based on the successful Wavescope demonstration at MSFC at the end of March, the decision was made by the optical testing team to purchase an upgraded Wavescope from AOA. The MSFC version would include: a higher resolution camera (1000 x 1000 pixels); a higher density lenslet array (150 x 150); updated software; and longer cables (to accommodate the remote operation of the Wavescope optical head which was resident in the Beam Guide Tube). The AOA proposal for the new instrument was received in mid-April, and delivered to MSFC in mid-July. A considerable amount of effort was expended to provide the infrastructure needed for Wavescope operation, and to incorporate it into the overall test system. This was provided by the Wavescope System Pallet (WSP) built by UAH. The WSP is illustrated. Several instruments are incorporated on this pallet. These include the: Wavescope optical head; a PDI wavefront sensor; a point spread function sensor; a Leica light-based distance measuring sensor. In addition there is a single mode fiber point source (fed from a separate source pallet) which serves both as a reference for the Wavescope and as a source point for the test mirror. There is a dual function lens which both collimates the beam from the test image point, and images the test mirror onto the lenslet array. There is a high quality Collimator which can provide a flat input wavefront directly into the Wavescope. There are also various aids such as an alignment laser, an alignment telescope, alignment sticks and apertures. The WSP was delivered to MSFC on 7/28/99. An picture shows the WSP installed in the Guide Tube at the X-Ray Calibration Facility (XRCF).
Extended duration Orbiter life support definition
NASA Technical Reports Server (NTRS)
Kleiner, G. N.; Thompson, C. D.
1978-01-01
Extending the baseline seven-day Orbiter mission to 30 days or longer and operating with a solar power module as the primary source for electrical power requires changes to the existing environmental control and life support (ECLS) system. The existing ECLS system imposes penalties on longer missions which limit the Orbiter capabilities and changes are required to enhance overall mission objectives. Some of these penalties are: large quantities of expendables, the need to dump or store large quantities of waste material, the need to schedule fuel cell operation, and a high landing weight penalty. This paper presents the study ground rules and examines the limitations of the present ECLS system against Extended Duration Orbiter mission requirements. Alternate methods of accomplishing ECLS functions for the Extended Duration Orbiter are discussed. The overall impact of integrating these options into the Orbiter are evaluated and significant Orbiter weight and volume savings with the recommended approaches are described.
NASA Technical Reports Server (NTRS)
Hilburger, Mark W.; Waters, W. Allen, Jr.; Haynie, Waddy T.; Thornburgh, Robert P
2017-01-01
Results from the testing of cylinder test article SBKF-P2-CYL-TA02 (referred to herein as TA02) are presented. TA02 is an 8-foot-diameter (96-inches), 78.0-inch-long, aluminum-lithium (Al-Li), orthogrid-stiffened cylindrical shell similar to those used in current state-of-the-art launch-vehicle structures and was designed to exhibit global buckling when subjected to combined compression and bending loads. The testing was conducted at the Marshall Space Flight Center (MSFC), February 3-6, 2009, in support of the Shell Buckling Knockdown Factor Project (SBKF). The test was used to verify the performance of a newly constructed buckling test facility at MSFC and to verify the test article design and analysis approach used by the SBKF researchers.
Calibration of the ART-XC/SRG X-ray Mirror Modules
NASA Technical Reports Server (NTRS)
Gubarev, M.; Ramsey, B.; Zavlin, V.; Swartz, D.; Kolodziejczak, J.; Elsner, R.; Pavlinsky, M.; Tkachenko, A.; Lapshov, I.
2014-01-01
Seven x-ray mirror modules are being fabricated at the Marshall Space Flight Center (MSFC) for the Astronomical Roentgen Telescope (ART) instrument to be launched on board of the Spektrum Roentgen Gamma (SRG) Mission. As they are completed, the modules are tested and calibrated at the MSFC's 104-m Stray Flight Facility. The results of these calibration measurements and comparisons with theoretical models will be presented.
1965-03-01
S-IB-1, the first flight version of the Saturn IB launch vehicle's first stage (S-IB stage), sat in the Marshall Space Flight Center (MSFC) Saturn IB static test stand on March 15, 1965. Developed by the MSFC and built by the Chrysler Corporation at the Michoud Assembly Facility (MAF) in New Orleans, Louisiana, the 90,000-pound booster utilized eight H-1 engines to produce a combined thrust of 1,600,000 pounds.
1965-03-04
Pictured is a J-2 engine being processed at Marshall Space Flight Center (MSFC). A single J-2 engine was utilized on the S-IVB stage, the second stage of the Saturn IB and the third stage of the Saturn V vehicles, while a cluster of five J-2 engines powered the second (S-II) stage of the Saturn V launch vehicle. The Saturn V was designed, developed, and tested by engineers at MSFC.
Focal Point Inside the Vacuum Chamber for Solar Thermal Propulsion
NASA Technical Reports Server (NTRS)
1999-01-01
Researchers at the Marshall Space Flight Center (MSFC) have designed, fabricated, and tested the first solar thermal engine, a non-chemical rocket engine that produces lower thrust but has better thrust efficiency than a chemical combustion engine. MSFC turned to solar thermal propulsion in the early 1990s due to its simplicity, safety, low cost, and commonality with other propulsion systems. Solar thermal propulsion works by acquiring and redirecting solar energy to heat a propellant. The 20- by 24-ft heliostat mirror (not shown in this photograph) has dual-axis control that keeps a reflection of the sunlight on an 18-ft diameter concentrator mirror, which then focuses the sunlight to a 4-in focal point inside the vacuum chamber. The focal point has 10 kilowatts of intense solar power. This photograph is a close-up view of a 4-in focal point inside the vacuum chamber at the MSFC Solar Thermal Propulsion Test facility. As part of MSFC's Space Transportation Directorate, the Propulsion Research Center serves as a national resource for research of advanced, revolutionary propulsion technologies. The mission is to move the Nation's capabilities beyond the confines of conventional chemical propulsion into an era of aircraft-like access to Earth orbit, rapid travel throughout the solar system, and exploration of interstellar space.
1999-08-01
Researchers at the Marshall Space Flight Center (MSFC) have designed, fabricated, and tested the first solar thermal engine, a non-chemical rocket engine that produces lower thrust but has better thrust efficiency than a chemical combustion engine. MSFC turned to solar thermal propulsion in the early 1990s due to its simplicity, safety, low cost, and commonality with other propulsion systems. Solar thermal propulsion works by acquiring and redirecting solar energy to heat a propellant. The 20- by 24-ft heliostat mirror (not shown in this photograph) has dual-axis control that keeps a reflection of the sunlight on an 18-ft diameter concentrator mirror, which then focuses the sunlight to a 4-in focal point inside the vacuum chamber. The focal point has 10 kilowatts of intense solar power. This photograph is a close-up view of a 4-in focal point inside the vacuum chamber at the MSFC Solar Thermal Propulsion Test facility. As part of MSFC's Space Transportation Directorate, the Propulsion Research Center serves as a national resource for research of advanced, revolutionary propulsion technologies. The mission is to move the Nation's capabilities beyond the confines of conventional chemical propulsion into an era of aircraft-like access to Earth orbit, rapid travel throughout the solar system, and exploration of interstellar space.
1999-08-01
Researchers at the Marshall Space Flight Center (MSFC) have designed, fabricated and tested the first solar thermal engine, a non-chemical rocket engine that produces lower thrust but has better thrust efficiency than a chemical combustion engine. MSFC turned to solar thermal propulsion in the early 1990s due to its simplicity, safety, low cost, and commonality with other propulsion systems. Solar thermal propulsion works by acquiring and redirecting solar energy to heat a propellant. This photograph, taken at MSFC's Solar Thermal Propulsion Test Facility, shows a concentrator mirror, a combination of 144 mirrors forming this 18-ft diameter concentrator, and a vacuum chamber that houses the focal point. The 20- by 24-ft heliostat mirror (not shown in this photograph) has a dual-axis control that keeps a reflection of the sunlight on the 18-foot diameter concentrator mirror, which then focuses the sunlight to a 4-in focal point inside the vacuum chamber. The focal point has 10 kilowatts of intense solar power. As part of MSFC's Space Transportation Directorate, the Propulsion Research Center serves as a national resource for research of advanced, revolutionary propulsion technologies. The mission is to move the Nation's capabilities beyond the confines of conventional chemical propulsion into an era of aircraft-like access to Earth-orbit, rapid travel throughout the solar system, and exploration of interstellar space.
Dr. Monaco Examines Lab-on a-Chip
NASA Technical Reports Server (NTRS)
2003-01-01
Dr. Lisa Monaco, Marshall Space Flight Center's (MSFC's) project scientist for the Lab-on-a-Chip Applications Development (LOCAD) program, examines a lab on a chip. The small dots are actually ports where fluids and chemicals can be mixed or samples can be collected for testing. Tiny channels, only clearly visible under a microscope, form pathways between the ports. Many chemical and biological processes, previously conducted on large pieces of laboratory equipment, can now be performed on these small glass or plastic plates. Monaco and other researchers at MSFC in Huntsville, Alabama, are customizing the chips to be used for many space applications, such as monitoring microbes inside spacecraft and detecting life on other planets. The portable, handheld Lab-on-a Chip Application Development Portable Test System (LOCAD-PTS) made its debut flight aboard Discovery during the STS-116 mission launched December 9, 2006. The system allowed crew members to monitor their environment for problematic contaminants such as yeast, mold, and even E.coli, and salmonella. Once LOCAD-PTS reached the International Space Station (ISS), the Marshall team continued to manage the experiment, monitoring the study from a console in the Payload Operations Center at MSFC. The results of these studies will help NASA researchers refine the technology for future Moon and Mars missions. (NASA/MSFC/D.Stoffer)
Environmental Control and Life Support Systems Testing Facility at MSFC
NASA Technical Reports Server (NTRS)
2001-01-01
The Marshall Space Flight Center (MSFC) is responsible for designing and building the life support systems that will provide the crew of the International Space Station (ISS) a comfortable environment in which to live and work. Scientists and engineers at the MSFC are working together to provide the ISS with systems that are safe, efficient, and cost-effective. These compact and powerful systems are collectively called the Environmental Control and Life Support Systems, or simply, ECLSS. This photograph shows the Urine Processor Assembly (UPA) which utilizes the Vapor Compression Distillation (VCD) technology. The VCD is used for integrated testing of the entire Water Recovery System (WRS) and development testing of the Urine Processor Assembly. The UPA accepts and processes pretreated crewmember urine to allow it to be processed along with other wastewaters in the Water Processor Assembly (WPA). The WPA removes free gas, organic, and nonorganic constituents before the water goes through a series of multifiltration beds for further purification. Product water quality is monitored primarily through conductivity measurements. Unacceptable water is sent back through the WPA for reprocessing. Clean water is sent to a storage tank.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richter, M.M.; Bard, A.J.
The electrochemistry and electrogenerated chemiluminescence (ECL) of a series of europium chelates, cryptates, and mixed-ligand chelate/cryptand complexes were studied. The complexes were of the following general forms: EuL{sub 4}{sup -}, where L = {beta}-diketonate, a bis-chelating ligand (such as dibenzoylmethide), added as salts (A)EuL{sub 4}, where A= tetrabutylammonium ion or piperidinium ion (pipH{sup +}); Eu(crypt){sup 3+}, where crypt = a cryptand ligand, e.g., 4,7,13,16,21-pentaoxa-1,10-diazabicyclo[8,8,5]-tricosa ne; and Eu(crypt)(L){sup 2+} for the mixed-ligand systems. ECL was obtained for the chelates and mixed-ligand systems by reducing the complexes at a Pt electrode in the presence of peroxydisulfate in acetonitrile solutions and was attributedmore » to the electron-transfer reaction between the reduced bound ligands and SO{sub 4}{sup .-}, followed by intramolecular excitation transfer from the excited ligand orbitals to the metal-centered 4f states. No ECL was observed under the same conditions for the europium complexes incorporating only the cryptand ligands in aqueous solution. The ECL spectra matched the photoluminescence spectra with a narrow emission band observed at 612 nm, corresponding to a metal-centered 4f-4f transition. The ECL efficiencies for the ECL-active species were low, about 10{sup -1}-10{sup -4}% of that of the Ru-(bpy){sub 3}{sup 2+}/S{sub 2}O{sub 8}{sup 2-} system under similar conditions. 38 refs., 6 figs., 2 tabs.« less
Jiang, Xinya; Chai, Yaqin; Wang, Haijun; Yuan, Ruo
2014-04-15
A novel and ultrasensitive electrochemiluminescence (ECL) immunosensor, which was based on the amplifying ECL of luminol by hemin-reduced graphene oxide (hemin-rGO) and Ag nanoparticles (AgNPs) decorated reduced graphene oxide (Ag-rGO), was constructed for the detection of carcinoembryonic antigen (CEA). For this proposed sandwich-type ECL immunosensor, Au nanoparticles electrodeposited (DpAu) onto hemin-rGO (DpAu/hemin-rGO) constructed the base of the immunosensor. DpAu had outstanding electrical conductivity to promote the electron transfer at the electrode interface and had good biocompatibility to load large amounts of primary antibody (Ab1), which provided an excellent platform for this immunosensor. Moreover, AgNPs and glucose oxidase (GOD) functionalized graphene labeled secondary antibody (Ag-rGO-Ab2-GOD) was designed as the signal probe for the sandwiched immunosensor. Not only did the hemin-rGO improve the electron transfer of the electrode surface, but hemin also further amplified the ECL signal of luminol in the presence of hydrogen peroxide (H2O2). With the aid of Ag-rGO-Ab2-GOD, enhanced signal was obtained by in situ generation of H2O2 and catalysis of AgNPs to ECL reaction of the luminol-H2O2 system. The as-prepared ECL immunosensor exhibited excellent analytical property for the detection of CEA in the range from 0.1 pg mL(-1) to 160 ng mL(-1) with a detection limit of 0.03 pg mL(-1) (SN(-1)=3). © 2013 Published by Elsevier B.V.
Chen, Xiaomei; Lian, Sai; Ma, Ying; Peng, Aihong; Tian, Xiaotian; Huang, Zhiyong; Chen, Xi
2016-01-01
In this work, a sensitive electrochemiluminescence (ECL) sensor for the determination of melamine (MEL) was developed based on a Ru(bpy)3(2+)-doped silica nanoparticles (RUDS)/carboxylic acid functionalized multi-walled carbon nanotubes (CMWCNTs)/Nafion composite film modified electrode. The homogeneous spherical RUDS were synthesized by a reverse microemulsion method. As Ru(bpy)3(2+) were encapsulated in the RUDS, Ru(bpy)3(2+) dropping from the modified electrode can be greatly prevented, which is helpful for obtaining a stable ECL signal. Moreover, to improve the conductivity of the film and promote the electron transfer rate on electrode surface, CMWCNTs with excellent electrical conductivity and large surface area were applied in the construction of the sensing film. As CMWCNTs acted as electron bridges making more Ru(bpy)3(2+) participate in the reaction, the ECL intensity was greatly enhanced. Under the optimum conditions, the relative ECL signal (△IECL) was proportional to the logarithmic MEL concentration ranging from 5×10(-13) to 1×10(-7) mol L(-1) with a detection limit of 1×10(-13) mol L(-1). To verify the reliability, the thus-fabricated ECL sensor was applied to determine the concentration of MEL in milk. Based on these investigations, the proposed ECL sensor exhibited good feasibility and high sensitivity for the determination of MEL, promising the applicability of this sensor in practical analysis. Copyright © 2015 Elsevier B.V. All rights reserved.
Kodak Mirror Assembly Tested at Marshall Space Flight Center
NASA Technical Reports Server (NTRS)
2003-01-01
The Eastman-Kodak mirror assembly is being tested for the James Webb Space Telescope (JWST) project at the X-Ray Calibration Facility at Marshall Space Flight Center (MSFC). In this photo, an MSFC employee is inspecting one of many segments of the mirror assembly for flaws. MSFC is supporting Goddard Space Flight Center (GSFC) in developing the JWST by taking numerous measurements to predict its future performance. The tests are conducted in a vacuum chamber cooled to approximate the super cold temperatures found in space. During its 27 years of operation, the facility has performed testing in support of a wide array of projects, including the Hubble Space Telescope (HST), Solar A, Chandra technology development, Chandra High Resolution Mirror Assembly and science instruments, Constellation X-Ray Mission, and Solar X-Ray Imager, currently operating on a Geostationary Operational Environment Satellite. The JWST is NASA's next generation space telescope, a successor to the Hubble Space Telescope, named in honor of NASA's second administrator, James E. Webb. It is scheduled for launch in 2010 aboard an expendable launch vehicle. It will take about 3 months for the spacecraft to reach its destination, an orbit of 940,000 miles in space.
Green Propulsion Auxiliary Power Unit Demonstration at MSFC
NASA Technical Reports Server (NTRS)
Robinson, Joel W.
2014-01-01
In 2012, the National Aeronautics & Space Administration (NASA) Space Technology Mission Directorate (STMD) began the process of building an integrated technology roadmap, including both technology pull and technology push strategies. Technology Area 1 (TA-01)1 for Launch Propulsion Systems is one of fourteen TAs that provide recommendations for the overall technology investment strategy and prioritization of NASA's space technology activities. Identified within TA-01 was the need for a green propulsion auxiliary power unit (APU) for hydraulic power by 2015. Engineers led by the author at the Marshall Space Flight Center (MSFC) have been evaluating green propellant alternatives and have begun the development of an APU test bed to demonstrate the feasibility of use. NASA has residual APU assets remaining from the retired Space Shuttle Program. Likewise, the F-16 Falcon fighter jet also uses an Emergency Power Unit (EPU) that has similar characteristics to the NASA hardware. Both EPU and APU components have been acquired for testing at MSFC. This paper will summarize the status of the testing efforts of green propellant from the Air Force Research Laboratory (AFRL) propellant AFM315E based on hydroxyl ammonium nitrate (HAN) with these test assets.
Ogrinc, Greg; Hoffman, Kimberly G.; Stevenson, Katherine M.; Shalaby, Marc; Beard, Albertine S.; Thörne, Karin E.; Coleman, Mary T.; Baum, Karyn D.
2016-01-01
Problem Current models of health care quality improvement do not explicitly describe the role of health professions education. The authors propose the Exemplary Care and Learning Site (ECLS) model as an approach to achieving continual improvement in care and learning in the clinical setting. Approach From 2008–2012, an iterative, interactive process was used to develop the ECLS model and its core elements—patients and families informing process changes; trainees engaging both in care and the improvement of care; leaders knowing, valuing, and practicing improvement; data transforming into useful information; and health professionals competently engaging both in care improvement and teaching about care improvement. In 2012–2013, a three-part feasibility test of the model, including a site self-assessment, an independent review of each site’s ratings, and implementation case stories, was conducted at six clinical teaching sites (in the United States and Sweden). Outcomes Site leaders reported the ECLS model provided a systematic approach toward improving patient (and population) outcomes, system performance, and professional development. Most sites found it challenging to incorporate the patients and families element. The trainee element was strong at four sites. The leadership and data elements were self-assessed as the most fully developed. The health professionals element exhibited the greatest variability across sites. Next Steps The next test of the model should be prospective, linked to clinical and educa tional outcomes, to evaluate whether it helps care delivery teams, educators, and patients and families take action to achieve better patient (and population) outcomes, system performance, and professional development. PMID:26760058
Thermal and Fluid Modeling of the CRYogenic Orbital TEstbed (CRYOTE) Ground Test Article (GTA)
NASA Technical Reports Server (NTRS)
Piryk, David; Schallhorn, Paul; Walls, Laurie; Stopnitzky, Benny; Rhys, Noah; Wollen, Mark
2012-01-01
The purpose of this study was to anchor thermal and fluid system models to data acquired from a ground test article (GTA) for the CRYogenic Orbital TEstbed - CRYOTE. To accomplish this analysis, it was broken into four primary tasks. These included model development, pre-test predictions, testing support at Marshall Space Flight Center (MSFC} and post-test correlations. Information from MSFC facilitated the task of refining and correlating the initial models. The primary goal of the modeling/testing/correlating efforts was to characterize heat loads throughout the ground test article. Significant factors impacting the heat loads included radiative environments, multi-layer insulation (MLI) performance, tank fill levels, tank pressures, and even contact conductance coefficients. This paper demonstrates how analytical thermal/fluid networks were established, and it includes supporting rationale for specific thermal responses seen during testing.
2002-10-11
KENNEDY SPACE CENTER, FLA. -- Pete Engel, an engineering specialist in Wyle Laboratory's Nondestructive Testing Laboratory at KSC, explains the testing being performed on a 100-pound Mundrabilla meteorite sample. The one-of-a-kind meteorite was found 36 years ago in Australia and is on loan to Marshall Space Flight Center (MSFC) from the Smithsonian Institution's National Museum of Natural History. Dr. Donald Gillies, discipline scientist for materials science at MSFC's Microgravity Science and Applications Department, is the Principal Investigator. The studies may help provide the science community and industry with fundamental knowledge for use in the design of advanced materials.
2002-10-11
KENNEDY SPACE CENTER, FLA. -- Pete Engel, an engineering specialist in Wyle Laboratory's Nondestructive Testing Laboratory at KSC, explains the testing being performed on a 100-pound Mundrabilla meteorite sample. The one-of-a-kind meteorite was found 36 years ago in Australia and is on loan to Marshall Space Flight Center (MSFC) from the Smithsonian Institution's National Museum of Natural History. Dr. Donald Gillies, discipline scientist for materials science at MSFC's Microgravity Science and Applications Department, is the Principal Investigator. The studies may help provide the science community and industry with fundamental knowledge for use in the design of advanced materials.
1967-09-09
This image depicts the test firing of a J-2 engine in the S-IVB Test Stand at the Marshall Space Flight Center (MSFC). The J-2, developed by Rocketdyne under the direction of MSFC, was propelled by liquid hydrogen and liquid oxygen. A single J-2 was utilized in the S-IVB stage (the second stage for the Saturn IB and third stage for the Saturn V) and in a cluster of five for the second stage (S-II) of the Saturn V. Initially rated at 200,000 pounds of thrust, the engine was later upgraded in the Saturn V program to 230,000 pounds.
1964-10-01
The components of the Saturn V booster (S-IC stage) fuel tank are shown in this photograph. The liquid oxygen tank bulkhead on the left and both halves of the fuel tank were in the Marshall Space Flight Center (MSFC) Manufacturing Engineering Laboratory, building 4707. These components were used at MSFC in structural testing to prove that they could withstand the forces to which they were subjected in flight. Each S-IC stage has two tanks, one for kerosene and one for liquid oxygen, made from such components as these. Thirty-three feet in diameter, they hold a total of 4,400,000 pounds of fuel. Although this tankage was assembled at MSFC, the elements were made by the Boeing Company at Wichita and the Michoud Operations at New Orleans.
Foundations of Mathematics Achievement: Instructional Practices and Diverse Kindergarten Students
ERIC Educational Resources Information Center
Bottia, Martha Cecilia; Moller, Stephanie; Mickelson, Roslyn Arlin; Stearns, Elizabeth
2014-01-01
Analyzing Early Childhood Longitudinal Survey--Kindergarten (ECLS-K) data, we examine how exposure to instructional practices influences math test scores at the end of kindergarten for children from different racial/ethnic and socioeconomic backgrounds, and for children with different levels of math skills at kindergarten entry. We also analyze…
Instructional Approaches in Kindergarten: What Works for Whom?
ERIC Educational Resources Information Center
Chiatovich, Tara; Stipek, Deborah
2016-01-01
This study used ECLS-K 1998-1999 data to evaluate whether specific kindergarten teaching practices predicted school-year learning gains differently, depending on children's ethnicity, SES, and fall test scores. Exploratory factor analyses guided the creation of four literacy and five math instruction composites from teachers' reports of their…
DOE Office of Scientific and Technical Information (OSTI.GOV)
FISCHER,W.
We summarize the ECL2 workshop on electron cloud clearing, which was held at CERN in early March 2007, and highlight a number of novel ideas for electron cloud suppression, such as continuous clearing electrodes based on enamel, slotted structures, and electrete inserts.
Moon, B H; Chaoumead, A; Sung, Y M
2013-10-01
Fluorine-doped tin oxide (FTO) materials synthesized by sol-gel combustion method were investigated for electrochemical luminescence (ECL) application. Effects of sol-gel combustion conditions on the structures and morphology of the porous FTO (p-FTO) materials were studied. ECL efficiency of p-FTO-based cell was about 251 cd/m2 at 4 V bias, which is higher than the sell using only FTO electrodes (102.8 cd/m2). The highest intensity of the emitting light was obtained at the wavelength of about 610 nm. The porous FTO layer was effective for increasing ECL intensities.
Yu, Yingchang; Lu, Chao; Zhang, Meining
2015-08-04
Herein, it is the first report that a cathodic electrochemiluminescence (ECL) resonance energy transfer (ERET) system is fabricated by layer-by-layer (LBL) electrostatic assembly of CoAl layered double hydroxide (LDH) nanosheets with a mixture of blue BSA-gold nanoclusters (AuNCs) and Ru(bpy)3(2+) (denoted as AuNCs@Ru) on an Au electrode. The possible ECL mechanism indicates that the appearance of CoAl-LDH nanosheets generates a long-range stacking order of the AuNCs@Ru on an Au electrode, facilitating the occurrence of the ERET between BSA-AuNC donors and Ru(bpy)3(2+) acceptors on the as-prepared AuNCs@Ru-LDH ultrathin films (UTFs). Furthermore, it is observed that the cathodic ECL intensity can be quenched efficiently in the presence of 6-mercaptopurine (6-MP) in a linear range of 2.5-100 nM with a detection limit of 1.0 nM. On the basis of these interesting phenomena, a facile cathodic ECL sensor has successfully distinguished 6-MP from other thiol-containing compounds (e.g., cysteine and glutathione) in human serum and urine samples. The proposed sensing scheme opens a way for employing the layered UTFs as a platform for the cathodic ECL of Ru(bpy)3(2+).
Zhong, Xia; Chai, Ya-Qin; Yuan, Ruo
2014-10-01
Well-distributed hollow gold nanospheres (Aushell@GOD) (20 ± 5 nm) were synthesized using the glucose oxidase (GOD) cross-linked with glutaraldehyde as a template. A glucose biosensor was prepared based on Aushell@GOD nanospheres for catalyzing luminol electrogenerated chemiluminescence (ECL). Firstly, chitosan was modified in a glassy carbon electrode which offered an interface of abundant amino-groups to assemble Aushell@GOD nanospheres. Then, glucose oxidase was adsorbed on the surface of Aushell@GOD nanospheres via binding interactions between Aushell and amino groups of GOD to construct a glucose biosensor. The Aushell@GOD nanospheres were investigated with TEM and UV-vis. The ECL behaviors of the biosensor were also investigated. Results showed that, the obtained Aushell@GOD nanospheres exhibited excellent catalytic effect towards the ECL of luminol-H2O2 system. The response of the prepared biosensor to glucose was linear with the glucose concentration in the range of 1.0 μM to 4.3mM (R=0.9923) with a detection limit of 0.3 μM (signal to noise=3). This ECL biosensor exhibited short response time and excellent stability for glucose. At the same time the prepared ECL biosensor showed good reproducibility, sensitivity and selectivity. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Jong, Jen-Yi
1996-01-01
NASA's advanced propulsion system Small Scale Magnetic Disturbances/Advanced Technology Development (SSME/ATD) has been undergoing extensive flight certification and developmental testing, which involves large numbers of health monitoring measurements. To enhance engine safety and reliability, detailed analysis and evaluation of the measurement signals are mandatory to assess its dynamic characteristics and operational condition. Efficient and reliable signal detection techniques will reduce the risk of catastrophic system failures and expedite the evaluation of both flight and ground test data, and thereby reduce launch turn-around time. During the development of SSME, ASRI participated in the research and development of several advanced non- linear signal diagnostic methods for health monitoring and failure prediction in turbomachinery components. However, due to the intensive computational requirement associated with such advanced analysis tasks, current SSME dynamic data analysis and diagnostic evaluation is performed off-line following flight or ground test with a typical diagnostic turnaround time of one to two days. The objective of MSFC's MPP Prototype System is to eliminate such 'diagnostic lag time' by achieving signal processing and analysis in real-time. Such an on-line diagnostic system can provide sufficient lead time to initiate corrective action and also to enable efficient scheduling of inspection, maintenance and repair activities. The major objective of this project was to convert and implement a number of advanced nonlinear diagnostic DSP algorithms in a format consistent with that required for integration into the Vanderbilt Multigraph Architecture (MGA) Model Based Programming environment. This effort will allow the real-time execution of these algorithms using the MSFC MPP Prototype System. ASRI has completed the software conversion and integration of a sequence of nonlinear signal analysis techniques specified in the SOW for real-time execution on MSFC's MPP Prototype. This report documents and summarizes the results of the contract tasks; provides the complete computer source code; including all FORTRAN/C Utilities; and all other utilities/supporting software libraries that are required for operation.
NASA Technical Reports Server (NTRS)
Bagdigian, R. M.; Traweek, M. S.; Griffith, G. K.; Griffin, M. R.
1991-01-01
A series of tests has been conducted at the NASA Marshall Space Flight Center (MSFC) to evaluate the performance of a predevelopment water recovery system. Potable, hygiene, and urine reclamation subsystems were integrated with end-use equipment items and successfully operated in open and partially closed-loop modes, with man-in-the-loop, for a total of 28 days. Several significant subsystem physical anomalies were encountered during testing. Reclaimed potable and hygiene water generally met the current Space Station Freedom (SSF) water quality specifications for inorganic and microbiological constituents, but exceeded the maximum allowable concentrations for Total Organic Carbon (TOC). This paper summarizes the test objectives, system design, test activities/protocols, significant results/anomalies, and major lessons learned.
Micrometeorite Impact Test of Flex Solar Array Coupon
NASA Technical Reports Server (NTRS)
Wright, K. H.; Schneider, T. A.; Vaughn, J. A.; Hoang, B.; Wong, F.; Gardiner, G.
2016-01-01
Spacecraft with solar arrays operate throughout the near earth environment and are planned for outer planet missions. An often overlooked test condition for solar arrays that is applicable to these missions is micrometeoroid impacts and possibly electrostatic discharge (ESD) events resulting from these impacts. NASA Marshall Space Flight Center (MSFC) is partnering with Space Systems/Loral, LLC (SSL) to examine the results of simulated micrometeoroid impacts on the electrical performance of an advanced, lightweight flexible solar array design. The test is performed at MSFC's Micro Light Gas Gun Facility with SSL-provided coupons. Multiple impacts were induced at various locations on a powered test coupon under different string voltage (0V-150V) and string current (1.1A - 1.65A) conditions. The setup, checkout, and results from the impact testing are discussed.
NASA Technical Reports Server (NTRS)
Allen, E. C.
1976-01-01
Information is presented for wind tunnel tests (IA125) of a 0.004-scale orbiter, external tank, and solid rocket motor integrated vehicle model (77-0 and 74-OTS) in the MSFC Trisonic Wind Tunnel. These tests were conducted in support of MCR's 1344 and 1346. Data from these tests provide spoiler effects on wing bending/torsion and elevon hinge moments, elevon effectiveness data and the influence of solid plumes from Mach numbers of 0.6 through 2.74 at angles of attack and sideslip from -10 through 10 degrees.
Changes in the Black-White Test score Gap in the Elementary School Grades. CSE Report 715
ERIC Educational Resources Information Center
Koretz, Daniel; Kim, Young-Suk
2007-01-01
In a pair of recent studies, Fryer and Levitt (2004a, 2004b) analyzed the Early Childhood Longitudinal Study--Kindergarten Cohort (ECLS-K) to explore the characteristics of the Black-White test score gap in young children. They found that the gap grew markedly between kindergarten and the third grade and that they could predict the gap from…
1972-01-01
This is a cutaway illustration of the Neutral Buoyancy Simulator (NBS) at the Marshall Space Flight Center (MSFC ). The MSFC NBS provided an excellent environment for testing hardware to examine how it would operate in space and for evaluating techniques for space construction and spacecraft servicing. Here, engineers, designers, and astronauts performed various tests to develop basic concepts, preliminary designs, final designs, and crew procedures. The NBS was constructed of welded steel with polyester-resin coating. The water tank was 75-feet (22.9- meters) in diameter, 40-feet (12.2-meters) deep, and held 1.32 million gallons of water. Since it opened for operation in 1968, the NBS had supported a number of successful space missions, such as the Skylab, Solar Maximum Mission Satellite, Marned Maneuvering Unit, Experimental Assembly of Structures in Extravehicular Activity/Assembly Concept for Construction of Erectable Space Structures (EASE/ACCESS), the Hubble Space Telescope, and the Space Station. The function of the MSFC NBS was moved to the larger simulator at the Johnson Space Center and is no longer operational.
NASA Technical Reports Server (NTRS)
1989-01-01
Two Active Radiation Dosimeters (ARD's) flown on Spacelab 1, performed without fault and were returned to Space Science Laboratory, MSFC for recalibration. During the flight, performance was monitored at the Huntsville Operations Center (HOSC). Despite some problems with the Shuttle data system handling the verification flight instrumentation (VFI), it was established that the ARD's were operating normally. Postflight calibrations of both units determined that sensitivities were essentially unchanged from preflight values. Flight tapes were received for approx. 60 percent of the flight and it appears that this is the total available. The data was analyzed in collaboration with Space Science Laboratory, MSFC. Also, the Nuclear Radiation Monitor (NRM) was assembled and tested at MSFC. Support was rendered in the areas of materials control and parts were supplied for the supplementary heaters, dome gas-venting device and photomultiplier tube housing. Performance characteristics of some flight-space photomultipliers were measured. The NRM was flown on a balloon-borne test flight and subsequently performed without fault on Spacelab-2. This data was analyzed and published.
NASA Technical Reports Server (NTRS)
Whalen, Jessie E. (Compiler); Mckinley, Sarah L. (Compiler); Gates, Thomas G. (Compiler)
1988-01-01
Listings of major events directly related to the Space Shuttle Program at Marshall Space Flight Center (MSFC) are presented. This information will provide the researcher with a means of following the chronological progression of the program. The products that the historians have prepared are intended to provide supportive research essential to the writing of formal narrative histories of Marshall's contributions to the Space Shuttle and Space Station.
ELV Payload Safety Program Workshop Green Propulsion Update
NASA Technical Reports Server (NTRS)
Robinson, Joel
2014-01-01
MSFC is engaged on the system solution: thrusters and power units; GRC is working plume diagnostics/modeling and independent thruster testing on GPIM.; GSFC is working slosh characteristics on GPIM tank.; JPL and ARC continually interested to infuse green propellant as potential replacement to hydrazine.; Mike Gazarik, AA of STMD, has requested MSFC lead the development of an Agency-level green propellant roadmap involving multiple Centers., Tentatively planned for August 2015 in Huntsville.
NASA Technical Reports Server (NTRS)
Bouldin, D. L.; Eastes, R. W.; Feltner, W. R.; Hollis, B. R.; Routh, D. E.
1979-01-01
The fabrication techniques for creation of complementary metal oxide semiconductor integrated circuits at George C. Marshall Space Flight Center are described. Examples of C-MOS integrated circuits manufactured at MSFC are presented with functional descriptions of each. Typical electrical characteristics of both p-channel metal oxide semiconductor and n-channel metal oxide semiconductor discrete devices under given conditions are provided. Procedures design, mask making, packaging, and testing are included.
1965-03-15
Workers at the Marshall Space Flight Center (MSFC) hoist S-IB-1, the first flight version of the Saturn IB launch vehicle's first stage (S-IB stage), into the Saturn IB static test stand on March 15, 1965. Developed by the MSFC and built by the Chrysler Corporation at the Michoud Assembly Facility (MAF) in New Orleans, Louisiana, the 90,000-pound booster utilized eight H-1 engines to produce a combined thrust of 1,600,000 pounds.
NASA GRC and MSFC Space-Plasma Arc Testing Procedures
NASA Technical Reports Server (NTRS)
Ferguson, Dale C.; Vayner, Boris V.; Galofaro, Joel T.; Hillard, G. Barry; Vaughn, Jason; Schneider, Todd
2007-01-01
Tests of arcing and current collection in simulated space plasma conditions have been performed at the NASA Glenn Research Center (GRC) in Cleveland, Ohio, for over 30 years and at the Marshall Space Flight Center (MSFC) in Huntsville, Alabama, for almost as long. During this period, proper test conditions for accurate and meaningful space simulation have been worked out, comparisons with actual space performance in spaceflight tests and with real operational satellites have been made, and NASA has achieved our own internal standards for test protocols. It is the purpose of this paper to communicate the test conditions, test procedures, and types of analysis used at NASA GRC and MSFC to the space environmental testing community at large, to help with international space-plasma arcing-testing standardization. Discussed herein are neutral gas conditions, plasma densities and uniformity, vacuum chamber sizes, sample sizes and Debye lengths, biasing samples versus self-generated voltages, floating samples versus grounded samples, test electrical conditions, arc detection, preventing sustained discharges during testing, real samples versus idealized samples, validity of LEO tests for GEO samples, extracting arc threshold information from arc rate versus voltage tests, snapover, current collection, and glows at positive sample bias, Kapton pyrolysis, thresholds for trigger arcs, sustained arcs, dielectric breakdown and Paschen discharge, tether arcing and testing in very dense plasmas (i.e. thruster plumes), arc mitigation strategies, charging mitigation strategies, models, and analysis of test results. Finally, the necessity of testing will be emphasized, not to the exclusion of modeling, but as part of a complete strategy for determining when and if arcs will occur, and preventing them from occurring in space.
Non-Nuclear Testing of Space Nuclear Systems at NASA MSFC
NASA Technical Reports Server (NTRS)
Houts, Michael G.; Pearson, Boise J.; Aschenbrenner, Kenneth C.; Bradley, David E.; Dickens, Ricky; Emrich, William J.; Garber, Anne; Godfroy, Thomas J.; Harper, Roger T.; Martin, Jim J.;
2010-01-01
Highly realistic non-nuclear testing can be used to investigate and resolve potential issues with space nuclear power and propulsion systems. Non-nuclear testing is particularly useful for systems designed with fuels and materials operating within their demonstrated nuclear performance envelope. Non-nuclear testing allows thermal hydraulic, heat transfer, structural, integration, safety, operational, performance, and other potential issues to be investigated and resolved with a greater degree of flexibility and at reduced cost and schedule compared to nuclear testing. The primary limit of non-nuclear testing is that nuclear characteristics and potential nuclear issues cannot be directly investigated. However, non-nuclear testing can be used to augment the potential benefit from any nuclear testing that may be required for space nuclear system design and development. This paper describes previous and ongoing non-nuclear testing related to space nuclear systems at NASA's Marshall Space Flight Center (MSFC).
EC-LEDS Supports the Low-Carbon Transition
DOE Office of Scientific and Technical Information (OSTI.GOV)
2016-09-01
EC-LEDS is a flagship U.S. government-led effort that assists countries to create and implement low emission development strategies, or LEDS -- development frameworks that promote sustainable social and economic development while reducing greenhouse gas emissions over the medium to long term.
Babamiri, Bahareh; Salimi, Abdollah; Hallaj, Rahman
2018-04-15
In the present study, an ultrasensitive electrochemiluminescence (ECL) aptasensing assay for selective detection of Hg 2+ was designed. In this electrochemiluminescence resonance energy transfer (ECL-RET) approach, Fe 3 O 4 @SiO 2 /dendrimers/QDs exhibited amplified ECL emissions (switch "on" state) and with the hybridization between T-rich ssDNA(S 1 ) immobilized on the Fe 3 O 4 @SiO 2 /dendrimers/QDs and AuNPs modified with complementary aptamer (AuNPs-S 2 ), the ECL of QDs nanocomposites was efficiently quenched (switch "off" state). In the presence of Hg 2+ ions, formation of strong and stable T-Hg 2+ -T complex led to the release of the AuNPs-S 2 from double-stranded DNA(dsDNA) and the recovery of the ECL signal of QDs (second signal switch "on" state). Under optimal conditions, Hg 2+ can be detected in a wide linear range from 20aM to 2µM with a very low detection limit of 2aM. The proposed ECL aptasensor showed high selectivity for Hg 2+ determination compared to other environmentally relevant metal ions at concentration ratio more than 1000 times. The aptasensor was used for detection Hg 2+ ions from samples of tap waters, carp and saltwater fishes with satisfactory results. The aptasensor exhibited high sensitivity, wide linear response (11 orders of magnitude), excellent reproducibility and stability. The proposed aptasensor will be a promising candidate for facile and rapid determination of Hg 2+ in environmental and fishery samples. Copyright © 2017 Elsevier B.V. All rights reserved.
Extracorporeal life support in the treatment of colchicine poisoning.
Boisramé-Helms, Julie; Rahmani, Hassène; Stiel, Laure; Tournoud, Christine; Sauder, Philippe
2015-01-01
Ingestions of Colchicum autumnale may lead to severe poisoning. It begins with gastrointestinal symptoms and leukocytosis, followed by multi-organ failure with shock and a possible late recovery phase. Mortality is highly dependent on the ingested dose. We report a case of accidental C. autumnale poisoning with refractory cardiogenic shock and eventual survival after extracorporeal life support (ECLS). A 68-year-old woman was admitted to the intensive care unit (ICU) on day 3 after ingestion of C. autumnale in a meal. She first suffered from nausea and vomiting leading to severe dehydration. She then developed multi-organ failure and refractory cardiogenic shock, with a mean arterial pressure nadir of 50 mmHg despite high doses of catecholamines and a left ventricular ejection fraction at 5-10%. Venous-arterial ECLS was therefore started at an initial rate of 3.5 L/min and 3,800 rev/min. Her symptoms also included pancytopenia on day 4 with diffuse bleeding requiring iterative blood product transfusion. Platelet and leukocyte count nadirs were 13 × 10(9)/L (normal range: 150-400 × 10(9)/L) and 0.77 × 10(9)/L (normal range: 4.2-10.7 × 10(9)/L), respectively. ECLS allowed good cardiac contractility recovery within a few days, with complications including bleeding made controllable. Indeed, because of hemostasis disorders, the patient presented hemoptysis and hematuria. She was treated with tranexamic acid and transfused with blood products. She received 15 erythrocyte concentrates, 13 platelet concentrates, and 7 fresh frozen plasma. ECLS was removed by day 10, with subsequent weaning from mechanical ventilation as well as from hemodialysis in the following days. This patient survives after the use of ECLS in Colchicum poisoning, with controllable complications. Thus, ECLS might be indicated to overcome the potentially refractory cardiogenic shock phase.
Liquid Oxygen (LO2) propellant conditioning concept testing
NASA Technical Reports Server (NTRS)
Perry, Gretchen L. E.; Orth, Michael S.; Mehta, Gopal K.
1993-01-01
Marshall Space Flight Center (MSFC) and industry contractors have undertaken activities to develop a simplified liquid oxygen (LO2) propellant conditioning concept for future expendable launch vehicles. The objective of these activities is to reduce operations costs and timelines and to improve safety of these vehicles. The approach followed has been to identify novel concepts through system level studies and demonstrate the feasibility of these concepts through small-scale and full-scale testing. Testing will also provide data for design guidelines and validation of analytical models. Four different concepts are being investigated: no-bleed, low-bleed, use of a recirculation line, and helium (He) bubbling. This investigation is being done under a Joint Institutional Research and Development (JIRAD) program currently in effect between MSFC and General Dynamics Space Systems (GDSS). A full-scale test article, which is a facsimile of a propellant feed duct with an attached section to simulate heat input from a LO2 turbopump, will be tested at the Cold Flow Facility at MSFC's West Test Area. Liquid nitrogen (LN2), which has similar properties to LO2, will be used in place of LO2 for safety and budget reasons. Work to date includes design and fabrication of the test article, design of the test facility and initial fabrication, development of a test matrix and test procedures, initial predictions of test output, and heat leak calibration and heat exchanger tests on the test article. The tests for all propellant conditioning concepts will be conducted in the summer of 1993, with the final report completed by October, 1993.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Geng, Hongwei; Pan, Shanlin; Hu, Dehong
In this paper, we studied the luminescence property and fluorescence lifetime mapping of MEH-PPV/PCBM system by using electrogenerated chemiluminescence (ECL) and time-correlated single photo counting (TC-SPC) technologies. The ECL results showed that the oxidation peak of MEH-PPV near 0.7 V (vs. SCE) and ECL response of films shifted positively towards 1.2 V when in the presence of PCBM. At the same time, the oxidation peak current density of MEH-PPV increases while the ECL response decreased with the loading of PCBM in the composite films. The fluorescence lifetime images clearly show that the lifetime fluctuation is effected by different substrates andmore » MEH-PPV/PCBM ratios. Meanwhile, the lifetime of MEH-PPV decreases with the increasing of film thickness. The lifetimes of MEH-PPV films on TiO2 substrate are lower than them of films on cover slips.« less
Electrochemiluminescence-PCR detection of genetically modified organisms
NASA Astrophysics Data System (ADS)
Liu, Jinfeng; Xing, Da; Shen, Xingyan; Zhu, Debin
2005-01-01
The detection methods for genetically modified (GM) components in foods have been developed recently. But many of them are complicated and time-consuming; some of them need to use the carcinogenic substance, and can"t avoid false-positive results. In this study, an electrochemiluminescence polymerase chain reaction (ECL-PCR) method for detection GM tobaccos is proposed. The Cauliflower mosaic virus 35S (CaMV35S) promoter was amplified by PCR, Then hybridized with a Ru(bpy)32+ (TBR)-labeled and a biotinylated probe. The hybridization products were captured onto streptavidin-coated paramagnetic beads, and detected by measuring the electrochemiluminescence (ECL) signal of the TBR label. Whether the tobaccos contain GM components was discriminated by detecting the ECL signal of CaMV35S promoter. The experiment results show that the detection limit for CaMV35S promoter is 100 fmol, and the GM components can be clearly identified in GM tobaccos. The ECL-PCR method provide a new means in GMOs detection due to its safety, simplicity and high efficiency.
Structure Prediction of the Second Extracellular Loop in G-Protein-Coupled Receptors
Kmiecik, Sebastian; Jamroz, Michal; Kolinski, Michal
2014-01-01
G-protein-coupled receptors (GPCRs) play key roles in living organisms. Therefore, it is important to determine their functional structures. The second extracellular loop (ECL2) is a functionally important region of GPCRs, which poses significant challenge for computational structure prediction methods. In this work, we evaluated CABS, a well-established protein modeling tool for predicting ECL2 structure in 13 GPCRs. The ECL2s (with between 13 and 34 residues) are predicted in an environment of other extracellular loops being fully flexible and the transmembrane domain fixed in its x-ray conformation. The modeling procedure used theoretical predictions of ECL2 secondary structure and experimental constraints on disulfide bridges. Our approach yielded ensembles of low-energy conformers and the most populated conformers that contained models close to the available x-ray structures. The level of similarity between the predicted models and x-ray structures is comparable to that of other state-of-the-art computational methods. Our results extend other studies by including newly crystallized GPCRs. PMID:24896119
Jiang, Hui; Ju, Huangxian
2007-09-01
This work elucidated the detailed electrochemiluminescence (ECL) process of the thioglycolic acid-capped CdSe quantum dots (QDs) film/peroxide aqueous system. The QDs were first electrochemically reduced to form electrons-injected QDs approximately -1.1 V, which then reduced hydrogen peroxide to produce OH* radical. The intermediate OH* radical was a key species for producing holes-injected QDs. The ECL emission with a peak at -1.114 V was demonstrated to come from the 1Se-1Sh transition emission. Using thiol compounds as the model molecules to annihilate the OH* radical, their quenching effects on ECL emission were studied. This effect led to a novel strategy for ECL sensing of the scavengers of hydroxyl radical. The detection results of thiol compounds showed high sensitivity, good precision, and acceptable accuracy, suggesting the promising application of the proposed method for quick detection of both scavengers and generators of hydroxyl radical in different fields.
Gao, Hongfei; Wen, Luke; Wu, Yuhua; Yan, Xiaohong; Li, Jun; Li, Xiaofei; Fu, Zhifeng; Wu, Gang
2018-05-23
A highly sensitive electrochemiluminescent (ECL) immunoassay targeting PAT/ bar protein was facilely developed for genetically modified (GM) rapeseed detection using carbon nanoparticles (CNPs) originally prepared from printer toner. In this work, CNPs linked with antibody for PAT/ bar protein were used to modify a working electrode. After an immunoreaction between the PAT/ bar protein and its antibody, the immunocomplex formed on the electrode receptor region resulted in an inhibition of electron transfer between the electrode surface and the ECL substance, thus led to a decrease of ECL response. Under the optimal conditions, the ECL responses linearly decreased as the increase of the PAT/ bar protein concentration and the GM rapeseed RF3 content in the ranges of 0.10-10 ng/mL and 0.050-1.0%, with the limits of detection of 0.050 ng/mL and 0.020% (S/N = 3). These results open a facile, sensitive, and rapid approach for the safety control of agricultural GM rape.
Li, Jianping; Yang, Bin; Pan, Hongcheng; Xu, Guobao
2018-06-30
The selective and sensitive detection of rare earth elements is thought to be difficult because the concentration of those elements in the sample is commonly at a low level and they normally have severe mutual interference which is caused by homologous chemical properties. In this study, a novel molecularly imprinted polymer (MIP) sensor was fabricated for highly sensitive and selective determination of ultra-trace Tb 3+ . The Tb 3+ -ethylenediaminetetraacetic acid complex (Tb-EDTA) as the template molecule was incorporated into mono-6-mercapto-β-cyclodextrin (mono-6-SH-β-CD) to form a Russian Matryoshka (RM)-structured molecule (CD/Tb-EDTA). Titanium isopropoxide was utilized in vapor sol-gel polymerization to construct MIP membrane. Moreover, the selectivity of the RM MIP sensor was remarkably enhanced by the "triple-selectivity" recognition of EDTA-to-Tb 3+ , β-CD-to-(Tb-EDTA), and 3D cavity-to-(CD/Tb-EDTA), while the sensitivity of the MIP sensor was significantly improved by ECL signal enhancement based on double amplification, in other words, the electrochemiluminescence resonance energy transfer (ECL-RET) between the ECL donor of CD/Tb-EDTA and the ECL acceptor of Ru(bpy) 3 2+ , and the ECL enhancement by the co-reactant of CD/Tb-EDTA on Ru(bpy) 3 Cl 2 . When the imprinted cavities were occupied by Tb-EDTA during rebinding, the host-guest inclusion structured complex was formed and the ECL intensities produced by the Ru(bpy) 3 Cl 2 ECL system increased with increasing concentration of Tb-EDTA. The proposed sensor was used for quantitative analysis of Tb 3+ with concentrations ranging from 8.00 × 10 -13 mol/L to 4.00 × 10 -9 mol/L and successfully applied to detect Tb 3+ in seawater samples. The detection limit of the sensor was found to be 3.90 × 10 -13 mol/L (DL = 3δ b /K), which is lower than previously reported values. Thus, the fabricated sensor is feasible for practical applications. Copyright © 2018 Elsevier B.V. All rights reserved.
MSFC Skylab program engineering and integration
NASA Technical Reports Server (NTRS)
1974-01-01
A technical history and managerial critique of the MSFC role in the Skylab program is presented. The George C. Marshall Space Flight Center had primary hardware development responsibility for the Saturn Workshop Modules and many of the designated experiments in addition to the system integration responsibility for the entire Skylab Orbital Cluster. The report also includes recommendations and conclusions applicable to hardware design, test program philosophy and performance, and program management techniques with potential application to future programs.
NASA MSFC hardware in the loop simulations of automatic rendezvous and capture systems
NASA Technical Reports Server (NTRS)
Tobbe, Patrick A.; Naumann, Charles B.; Sutton, William; Bryan, Thomas C.
1991-01-01
Two complementary hardware-in-the-loop simulation facilities for automatic rendezvous and capture systems at MSFC are described. One, the Flight Robotics Laboratory, uses an 8 DOF overhead manipulator with a work volume of 160 by 40 by 23 feet to evaluate automatic rendezvous algorithms and range/rate sensing systems. The other, the Space Station/Station Operations Mechanism Test Bed, uses a 6 DOF hydraulic table to perform docking and berthing dynamics simulations.
Space Environmental Effects Testing Capability at the Marshall Space Flight Center
NASA Technical Reports Server (NTRS)
DeWittBurns, H.; Craven, Paul; Finckenor, Miria; Nehls, Mary; Schneider, Todd; Vaughn, Jason
2012-01-01
Understanding the effects of the space environment on materials and systems is fundamental and essential for mission success. If not properly understood and designed for, the effects of the environment can lead to degradation of materials, reduction of functional lifetime, and system failure. In response to this need, the Marshall Space Flight Center has developed world class Space Environmental Effects (SEE) expertise and test facilities to simulate the space environment. Capabilities include multiple unique test systems comprising the most complete SEE testing capability available. These test capabilities include charged particle radiation (electrons, protons, ions), ultraviolet radiation (UV), vacuum ultraviolet radiation (VUV), atomic oxygen, plasma effects, space craft charging, lunar surface and planetary effects, vacuum effects, and hypervelocity impacts as well as the combination of these capabilities. In addition to the uniqueness of the individual test capabilities, MSFC is the only NASA facility where the effects of the different space environments can be tested in one location. Combined with additional analytical capabilities for pre- and post-test evaluation, MSFC is a one-stop shop for materials testing and analysis. The SEE testing and analysis are performed by a team of award winning experts nationally recognized for their contributions in the study of the effects of the space environment on materials and systems. With this broad expertise in space environmental effects and the variety of test systems and equipment available, MSFC is able to customize tests with a demonstrated ability to rapidly adapt and reconfigure systems to meet customers needs. Extensive flight experiment experience bolsters this simulation and analysis capability with a comprehensive understanding of space environmental effects.
Electronic Collaboration Logbook
NASA Astrophysics Data System (ADS)
Gysin, Suzanne; Mandrichenko, Igor; Podstavkov, Vladimir; Vittone, Margherita
2012-12-01
In HEP, scientific research is performed by large collaborations of organizations and individuals. The logbook of a scientific collaboration is an important part of the collaboration record. Often it contains experimental data. At Fermi National Accelerator Laboratory (FNAL), we developed an Electronic Collaboration Logbook (ECL) application, which is used by about 20 different collaborations, experiments and groups at FNAL. The ECL is the latest iteration of the project formerly known as the Control Room Logbook (CRL). We have been working on mobile (IOS and Android) clients for the ECL. We will present the history, current status and future plans of the project, as well as design, implementation and support solutions made by the project.
Cryogenic fluid management program at MSFC
NASA Technical Reports Server (NTRS)
Schmidt, G. R.; Hastings, L. J.
1990-01-01
Cryogenic fluid management (CFM) is an important aspect in the design and operation of spacecraft propellant systems. Consequently, it represents a key technology in the development of future vehicles for orbital transfer, lunar transit and manned interplanetary (i.e., Mars) missions. Because of Marshall Space Flight Center's (MSFC's) leading role in the definition of such vehicles, the center is currently managing and conducting a variety of tests to support development of this technology. The purpose of this paper is to summarize these activities and present their status within the context of CFM technology requirements. The first section reviews MSFC's role, identifies the major emphases and thrusts of its program, and presents the overall schedule. The final part comprises the bulk of the report, and describes at length the objectives, approach and status of each project.
1997-02-01
Researchers at the Marshall Space Flight Center (MSFC) have designed, fabricated, and tested the first solar thermal engine, a non-chemical rocket engine that produces lower thrust but has better thrust efficiency than a chemical combustion engine. This photograph shows components for the thermal propulsion engine being laid out prior to assembly. MSFC turned to solar thermal propulsion in the early 1990s due to its simplicity, safety, low cost, and commonality with other propulsion systems. As part of MSFC's Space Transportation Directorate, the Propulsion Research Center serves as a national resource for research of advanced, revolutionary propulsion technologies. The mission is to move the Nation's capabilities beyond the confines of conventional chemical propulsion into an era of aircraft-like access to Earth-orbit, rapid travel throughout the solar system, and exploration of interstellar space.
Development Issues for Lunar Regolith Simulants
NASA Technical Reports Server (NTRS)
Rickman, Doug; Carpenter, Paul; Sibille, Laurent; Owens, Charles; French, Raymond; McLemore, Carole
2006-01-01
Significant challenges and logistical issues exist for the development of standardized lunar regolith simulant (SLRS) materials for use in the development and testing of flight hardware for upcoming NASA lunar missions. A production program at Marshall Space Flight Center (MSFC) for the deployment of lunar mare basalt simulant JSC-lA is underway. Root simulants have been proposed for the development of a low-T mare basalt simulant and a high-Ca highland anorthosite simulant, as part of a framework of simulant development outlined in the 2005 Lunar Regolith Simulant Materials Workshop held at MSFC. Many of the recommendation for production and standardization of simulants have already been documented by the MSFC team. But there are a number of unanswered questions related to geology which need ta be addressed prior to the creation of the simulants.
Thermal Analysis and Testing of Fastrac Gas Generator Design
NASA Technical Reports Server (NTRS)
Nguyen, H.
1998-01-01
The Fastrac Engine is being developed by the Marshall Space Flight Center (MSFC) to help meet the goal of substantially reducing the cost of access to space. This engine relies on a simple gas-generator cycle, which burns a small amount of RP-1 and oxygen to provide gas to drive the turbine and then exhausts the spent fuel. The Fastrac program envisions a combination of analysis, design and hot-fire evaluation testing. This paper provides the supporting thermal analysis of the gas generator design. In order to ensure that the design objectives were met, the evaluation tests have started on a component level and a total of 15 tests of different durations were completed to date at MSFC. The correlated thermal model results will also be compared against hot-fire thermocouple data gathered.
Cycom 977-2 Composite Material: Impact Test Results
NASA Technical Reports Server (NTRS)
Engel, Carl D.; Herald, Stephen; Watkins, Casey
2005-01-01
The reaction frequency data from 13A testing by MSFC and WSTF appear well behaved for the sample number used by each and exhibit the same type of energy level dependency. The reaction frequency shift in energy level is unexplained at this time. All the 13A data suggest that only a small amount of material is consumed when reactions take place. At ambient pressure, most of not all reactions are quenched as indicated by the small mass loss. As test pressure is increased in LOX using 13B results. Cycom does not support initiation of reactions or propagations of reactions in GOX at 100 psis based on tests at MSFC and WSTF at 72 ft-lb impact energy. No batch effect was identified in LOX or GOX.
Cheng, Luisa W; Henderson, Thomas D; Lam, Tina I; Stanker, Larry H
2015-11-27
Botulinum neurotoxins (BoNT) are some of nature's most potent toxins. Due to potential food contamination, and bioterrorism concerns, the development of detection reagents, therapeutics and countermeasures are of urgent interest. Recently, we have developed a sensitive electrochemiluminescent (ECL) immunoassay for BoNT/B, using monoclonal antibodies (mAbs) MCS6-27 and anti-BoNT/B rabbit polyclonal antibodies as the capture and detector. The ECL assay detected as little as 1 pg/mL BoNT/B in the buffer matrix, surpassing the detection sensitivities of the gold standard mouse bioassays. The ECL assay also allowed detection of BoNT/B in sera matrices of up to 100% sera with negligible matrix effects. This highly-sensitive assay allowed the determination of the biological half-lives of BoNT/B holotoxin in vivo. We further tested the toxin neutralization potential of our monoclonal antibodies using the mouse systemic and oral intoxication models. A combination of mAbs protected mice in both pre- and post-exposure models to lethal doses of BoNT/B. MAbs were capable of increasing survival of animals when administered even 10 h post-intoxication in an oral model, suggesting a likely time for BoNT/B complexes to reach the blood stream. More sensitive detection assays and treatments against BoNT intoxication will greatly enhance efforts to combat botulism.
Cheng, Luisa W.; Henderson, Thomas D.; Lam, Tina I.; Stanker, Larry H.
2015-01-01
Botulinum neurotoxins (BoNT) are some of nature’s most potent toxins. Due to potential food contamination, and bioterrorism concerns, the development of detection reagents, therapeutics and countermeasures are of urgent interest. Recently, we have developed a sensitive electrochemiluminescent (ECL) immunoassay for BoNT/B, using monoclonal antibodies (mAbs) MCS6-27 and anti-BoNT/B rabbit polyclonal antibodies as the capture and detector. The ECL assay detected as little as 1 pg/mL BoNT/B in the buffer matrix, surpassing the detection sensitivities of the gold standard mouse bioassays. The ECL assay also allowed detection of BoNT/B in sera matrices of up to 100% sera with negligible matrix effects. This highly-sensitive assay allowed the determination of the biological half-lives of BoNT/B holotoxin in vivo. We further tested the toxin neutralization potential of our monoclonal antibodies using the mouse systemic and oral intoxication models. A combination of mAbs protected mice in both pre- and post-exposure models to lethal doses of BoNT/B. MAbs were capable of increasing survival of animals when administered even 10 h post-intoxication in an oral model, suggesting a likely time for BoNT/B complexes to reach the blood stream. More sensitive detection assays and treatments against BoNT intoxication will greatly enhance efforts to combat botulism. PMID:26633496
Chloride equilibrium potential in salamander cones
Thoreson, Wallace B; Bryson, Eric J
2004-01-01
Background GABAergic inhibition and effects of intracellular chloride ions on calcium channel activity have been proposed to regulate neurotransmission from photoreceptors. To assess the impact of these and other chloride-dependent mechanisms on release from cones, the chloride equilibrium potential (ECl) was determined in red-sensitive, large single cones from the tiger salamander retinal slice. Results Whole cell recordings were done using gramicidin perforated patch techniques to maintain endogenous Cl- levels. Membrane potentials were corrected for liquid junction potentials. Cone resting potentials were found to average -46 mV. To measure ECl, we applied long depolarizing steps to activate the calcium-activated chloride current (ICl(Ca)) and then determined the reversal potential for the current component that was inhibited by the Cl- channel blocker, niflumic acid. With this method, ECl was found to average -46 mV. In a complementary approach, we used a Cl-sensitive dye, MEQ, to measure the Cl- flux produced by depolarization with elevated concentrations of K+. The membrane potentials produced by the various high K+ solutions were measured in separate current clamp experiments. Consistent with electrophysiological experiments, MEQ fluorescence measurements indicated that ECl was below -36 mV. Conclusions The results of this study indicate that ECl is close to the dark resting potential. This will minimize the impact of chloride-dependent presynaptic mechanisms in cone terminals involving GABAa receptors, glutamate transporters and ICl(Ca). PMID:15579212
Jimenez-Ruiz, A; Grueso, E; Perez-Tejeda, P
2015-10-01
Electrogenerated chemiluminescence, ECL, reactions between tris(2,2'-bipyridine)ruthenium(II), [Ru(bpy)3](2+), and PAMAM GX.0 (X=1 and 2) dendrimers in an aqueous medium were carried out at pH10 (fully deprotonated dendrimer surface). ECL was detected in the presence of GX.0 dendrimers without addition of any known coreactant. Atomic force microscopy, AFM, measurements for GX.0 dendrimers in the presence of the [Ru(bpy)3](2+) complex were also done. AFM images showed the existence of aggregates (pillars) of globular shape, as well as interdendrimer networks forming fibers in the x-y direction for dendrimer aqueous solutions. ECL and AFM results in cooperation suggest that the coreactant effect of the end amine groups is improved by both the dendritic branched shells and the globular z-type aggregates. The ECL efficiency trends as a function of [GX.0] (whole range) can be interpreted taking into account the coreactant effect modulated by the presence of the z and x-y type aggregates. Importantly, ECL efficiency values can be taken as a measure of the change induced on the dendrimer aggregation in aqueous solutions when their concentrations rise. Redox potentials of the [Ru(bpy)3](3+/2+) couple in the presence of the G1.0 and G2.0 dendrimers were also determined. Copyright © 2015 Elsevier Inc. All rights reserved.
Huan, Juan; Liu, Qian; Fei, Airong; Qian, Jing; Dong, Xiaoya; Qiu, Baijing; Mao, Hanping; Wang, Kun
2015-11-15
An amplified solid-state electrochemiluminescence (ECL) biosensor for detection of cholesterol in near-infrared (NIR) range was constructed based on CdTe quantum dots (QDs) decorated multiwalled carbon nanotubes@reduced graphene nanoribbons (CdTe-MWCNTs@rGONRs), which were prepared by electrostatic interactions. The CdTe QDs decorated on the MWCNTs@rGONRs resulted in the amplified ECL intensity by ~4.5 fold and decreased onset potential by ~100 mV. By immobilization of the cholesterol oxidase (ChOx) and NIR CdTe-MWCNTs@rGONRs on the electrode surface, a solid-state ECL biosensor for cholesterol detection was constructed. When cholesterol was added to the detection solution, the immobilized ChOx catalyzed the oxidation of cholesterol to generate H2O2, which could be used as the co-reactant in the ECL system of CdTe-MWCNTs@rGONRs. The as-prepared biosensor exhibited good performance for cholesterol detection including good reproducibility, selectivity, and acceptable linear range from 1 μM to 1mM with a relative low detection limit of 0.33 μM (S/N=3). The biosensor was successfully applied to the determination of cholesterol in biological fluid and food sample, which would open a new possibility for development of solid-state ECL biosensors with NIR emitters. Copyright © 2015 Elsevier B.V. All rights reserved.
Sanchez-Glanville, Carlos; Brindle, Mary E; Spence, Tanya; Blackwood, Jaime; Drews, Tanya; Menzies, Steve; Lopushinsky, Steven R
2015-05-01
Extracorporeal life support (ECLS) is a life-saving technology for the critically ill child. Our objective was to evaluate the outcomes of an educational curriculum designed to introduce an ECLS program to a noncardiac pediatric surgical center. An interdisciplinary curriculum was developed consisting of didactic courses, animal labs, simulations, and debrief sessions. We reviewed all patients requiring ECLS between October 2011 and December 2013. All health care practitioners involved in the ECLS training curriculum were surveyed to evaluate their perception of the educational program. Primary outcomes include successful cannulation and 30-day survival. The knowledge and confidence improved with statistical significance (p<0.0001-0.0003) for all of the components of the training curriculum. The highest score was given to the simulations. Twenty-one patients underwent cannulation. All patients were successfully cannulated to bypass, including six (28.6%) ECPR. Median time from activation to cutting was 52min (IQR 40-72), and from cutting to bypass 40min (IQR 30-45). Sixteen patients (76.2%) were decannulated to a sustainable cardiac rhythm and survived 30-days. An ECLS curriculum incorporating simulation and dedicated practice seems to have eliminated the potential learning curve associated with the introduction of a complex technology to a novice environment. Copyright © 2015 Elsevier Inc. All rights reserved.
Zheng, Ruijuan; Zhong, Jianhai; Zhao, Chenhao; Lang, Xiaoling; Hu, Zhibiao; Luo, Jiangshui
2017-08-01
In this paper, a novel and ultrasensitive electrochemiluminescent sensor employing a solvothermal-synthesized CdS nanorod-modified pencil graphite electrode (CdS/PGE) for the determination of chlorogenic acid (CA) is fabricated. In the first step, the PGE surface is modified using CdS nanorods. In the next step, the developed electrode is used to detect CA using a electrochemiluminescent (ECL) technique, in which potassium persulfate (K 2 S 2 O 8 ) served as a co-reactant. The possible ECL mechanism is investigated, and the influences of pH and cyclic voltammetric scanning rate on the signal response are studied. The ECL intensity decreases quantitatively in relation to the concentration of the target molecule. Under optimized conditions, the linear correlation between the quenched ECL intensity and the logarithm of CA concentration is observed in the range from 2 × 10 -9 to 8 × 10 -7 mol L -1 with a limit of detection of 1 × 10 -9 mol L -1 . This proposed method is applied to the analysis of CA in honeysuckle flower, giving recoveries of 99-107%. The experimental results demonstrate that this ECL sensor shows good stability and reproducibility. Copyright © 2016 John Wiley & Sons, Ltd.
Chen, Hong; Chen, Qiong; Zhao, Yingying; Zhang, Fan; Yang, Fan; Tang, Jie; He, Pingang
2014-04-01
A sensitive and label-free electrochemiluminescence (ECL) aptasensor for the detection of adenosine triphosphate (ATP) was successfully designed using host-guest recognition between a metallocyclodextrin complex, i.e., tris(bipyridine)ruthenium(II)-β-cyclodextrin [tris(bpyRu)-β-CD], and an ATP-binding aptamer. In the protocol, the NH2-terminated aptamer was immobilized on a glassy carbon electrode (GCE) by a coupling interaction. After host-guest recognition between tris(bpyRu)-β-CD and aptamer, the tris(bpyRu)-β-CD/aptamer/GCE produced a strong ECL signal as a result of the photoactive properties of tris(bpyRu)-β-CD. However, in the presence of ATP, the ATP/aptamer complex was formed preferentially, which restricted host-guest recognition, and therefore less tris(bpyRu)-β-CD was attached to the GCE surface, resulting in an obvious decrease in the ECL intensity. Under optimal determination conditions, an excellent logarithmic linear relationship between the ECL decrease and ATP concentration was obtained in the range 10.0-0.05 nM, with a detection limit of 0.01 nM at the S/N ratio of 3. The proposed ECL-based ATP aptasensor exhibited high sensitivity and selectivity, without time-consuming signal-labeling procedures, and is considered to be a promising model for detection of aptamer-specific targets. Copyright © 2014. Published by Elsevier B.V.
Özçimen, Muammer; Uysal, Ismail Onder; Eryılmaz, Mehmet Akif; Kal, Ali
2010-11-01
To evaluate the results, complications, effectiveness, and operative results of the endocanalicular laser dacryocystorhinostomy (ECL DCR) in the distal obstructions of the lacrimal drainage system. Sixty eyes of 57 patients who had a diagnosis of distal obstruction of the lacrimal drainage system were evaluated retrospectively in this study. All patients underwent ECL DCR by diode laser between October 2008 and July 2009. Forty-nine patients (86%) were females, 8 patients (14%) were males, and age distribution was between 3 and 84 years old (median, 40 y). The canaliculi were intubated by a silicone tube. The patency of the nasolacrimal system was controlled by lacrimal lavage, loss of epiphora, and endoscopic evaluation of the endonasal rhinostomy site with routine follow-up scheduled at first day and 1-week, 1-month, and 3-month postoperative intervals. After the 60 ECL DCRs, 10 patients underwent revision ECL DCR because of the persistent epiphora. The patency of the nasolacrimal duct or the decrease of the symptoms was assigned as success. There were no symptoms at all in 83.3% of the patients. The ECL DCR in the treatment of the distal obstructions of the lacrimal drainage system was easily tolerated by the patients, cosmetically preferred because there was no incision and scar formation with high success rates, and a minimally invasive alternative technique.
Extracorporeal life support: moving at the speed of light.
Dalton, Heidi J
2011-09-01
Extracorporeal life support (ECLS), or extracorporeal membrane oxygenation (ECMO) as it is also known, has been used to support over 45,000 patients to date. Overall survival is 62%. After many years of no change in equipment and technology, there has been a recent flurry of new pumps, cannulas, and oxygenators available for ECLS use. While the impact of this new technology is not yet completely defined, initial results have found that these systems provide safe support with lower priming volumes and less bleeding complications. New cannulas are also available, some making it easier for venovenous support in patients, from infants through adults. The reported success of ECLS in patients with H1N1 during the 2009-2010 epidemic and the improved survival of patients randomized to the ECMO arm of a recently completed adult study of respiratory failure have also brought ECLS into the spotlight much more than other years. Whether these developments will usher in a new era of ECLS expansion to a wider range of patients will require close consideration and observation. Other areas that need to be further refined include anticoagulation management, treatment of bleeding complications, learning to "nurse" patients in an awake state, such as is done in some European (and a few United States) centers, and neurodevelopmental outcome on a long-term basis. 2011 Daedalus Enterprises
Xia, Hui; Li, Lingling; Yin, Zhouyang; Hou, Xiandeng; Zhu, Jun-Jie
2015-01-14
A dual signal amplification strategy for electrochemiluminescence (ECL) aptasensor was designed based on biobar-coded gold nanoparticles (Au NPs) and DNAzyme. CdSeTe@ZnS quantum dots (QDs) were chosen as the ECL signal probes. To verify the proposed ultrasensitive ECL aptasensor for biomolecules, we detected thrombin (Tb) as a proof-of-principle analyte. The hairpin DNA designed for the recognition of protein consists of two parts: the sequences of catalytical 8-17 DNAzyme and thrombin aptamer. Only in the presence of thrombin could the hairpin DNA be opened, followed by a recycling cleavage of excess substrates by catalytic core of the DNAzyme to induce the first-step amplification. One part of the fragments was captured to open the capture DNA modified on the Au electrode, which further connected with the prepared biobar-coded Au NPs-CdSeTe@ZnS QDs to get the final dual-amplified ECL signal. The limit of detection for Tb was 0.28 fM with excellent selectivity, and this proposed method possessed good performance in real sample analysis. This design introduces the new concept of dual-signal amplification by a biobar-coded system and DNAzyme recycling into ECL determination, and it is promising to be extended to provide a highly sensitive platform for various target biomolecules.
NASA Astrophysics Data System (ADS)
Tamiya, Eiichi; Inoue, Yuki; Saito, Masato
2018-03-01
We present a review of luminol-based electrochemiluminescence (ECL) biosensors that perform enzymatic reactions and bioanalysis using antioxidant molecules by controlling the spatiotemporal production of a luminescent substrate, catalase activity, and glycated albumin (GA). The ECL intensity depends on the antioxidant capacity because radicals are neutralized by the antioxidants, which suppresses the luminescence. The antioxidant capacities of 22 types beverages were evaluated by comparison with a standard curve of Trolox. The time necessary for the ECL measurement of the antioxidant capacity is only 2 min with screen-printed electrodes and a portable ECL measurement system. Our system was also used to monitor reactive oxygen species released from neutrophils, which play an important role in the immune system, defending against viral and bacterial infections. The quenching of ECL imaging by catalase reaction localized in the multichamber electrode using the electrogenerated substrate was examined as a potential candidate for a sensitive reporting system. The substrate was successfully generated at applied potentials between -1 and -0.4 V in multichamber electrodes and the substrate confinement within the chamber was observed within 60 s of generation. The microchamber electrode system demonstrated a detection limit of 90 fM catalase. We also demonstrated a detection limit of 0.1 µM GA in human serum albumin, which is an improvement of about 70 times over colorimetric methods.
1973-05-01
This photograph was taken during testing of an emergency procedure to free jammed solar array panels on the Skylab workshop. A metal strap became tangled over one of the folded solar array panels when Skylab lost its micrometeoroid shield during the launch. This photograph shows astronauts Schweickart and Gibson in the Marshall Space Flight Center (MSFC) Neutral Buoyancy Simulator (NBS) using various cutting tools and methods developed by the MSFC to free the jammed solar wing. Extensive testing and many hours of practice in simulators such as the NBS tank helped prepare the Skylab crewmen for extravehicular performance in the weightless environment. This huge water tank simulated the weightless environment that the astronauts would encounter in space.
Solar Thermal Propulsion Test Facility
NASA Technical Reports Server (NTRS)
1999-01-01
Researchers at the Marshall Space Flight Center (MSFC) have designed, fabricated, and tested the first solar thermal engine, a non-chemical rocket engine that produces lower thrust but has better thrust efficiency than a chemical combustion engine. MSFC turned to solar thermal propulsion in the early 1990s due to its simplicity, safety, low cost, and commonality with other propulsion systems. Solar thermal propulsion works by acquiring and redirecting solar energy to heat a propellant. This photograph shows a fully assembled solar thermal engine placed inside the vacuum chamber at the test facility prior to testing. The 20- by 24-ft heliostat mirror (not shown in this photograph) has a dual-axis control that keeps a reflection of the sunlight on the 18-ft diameter concentrator mirror, which then focuses the sunlight to a 4-in focal point inside the vacuum chamber. The focal point has 10 kilowatts of intense solar power. As part of MSFC's Space Transportation Directorate, the Propulsion Research Center serves as a national resource for research of advanced, revolutionary propulsion technologies. The mission is to move theNation's capabilities beyond the confines of conventional chemical propulsion into an era of aircraft-like access to Earth orbit, rapid travel throughout the solar system, and exploration of interstellar space.
NASA Technical Reports Server (NTRS)
1999-01-01
Researchers at the Marshall Space Flight Center (MSFC) have designed, fabricated, and tested the first solar thermal engine, a non-chemical rocket engine that produces lower thrust but has better thrust efficiency than a chemical combustion engine. MSFC turned to solar thermal propulsion in the early 1990s due to its simplicity, safety, low cost, and commonality with other propulsion systems. Solar thermal propulsion works by acquiring and redirecting solar energy to heat a propellant. The 20- by 24-ft heliostat mirror (not shown in this photograph) has a dual-axis control that keeps a reflection of the sunlight on the 18-ft diameter concentrator mirror, which then focuses the sunlight to a 4-in focal point inside the vacuum chamber. The focal point has 10 kilowatts of intense solar power. This image, taken during the test, depicts the light being concentrated into the focal point inside the vacuum chamber. As part of MSFC's Space Transportation Directorate, the Propulsion Research Center serves as a national resource for research of advanced, revolutionary propulsion technologies. The mission is to move the Nation's capabilities beyond the confines of conventional chemical propulsion into an era of aircraft-like access to Earth orbit, rapid travel throughout the solar system, and exploration of interstellar space.
1999-11-01
Researchers at the Marshall Space Flight Center (MSFC) have designed, fabricated, and tested the first solar thermal engine, a non-chemical rocket engine that produces lower thrust but has better thrust efficiency than a chemical combustion engine. MSFC turned to solar thermal propulsion in the early 1990s due to its simplicity, safety, low cost, and commonality with other propulsion systems. Solar thermal propulsion works by acquiring and redirecting solar energy to heat a propellant. This photograph shows a fully assembled solar thermal engine placed inside the vacuum chamber at the test facility prior to testing. The 20- by 24-ft heliostat mirror (not shown in this photograph) has a dual-axis control that keeps a reflection of the sunlight on the 18-ft diameter concentrator mirror, which then focuses the sunlight to a 4-in focal point inside the vacuum chamber. The focal point has 10 kilowatts of intense solar power. As part of MSFC's Space Transportation Directorate, the Propulsion Research Center serves as a national resource for research of advanced, revolutionary propulsion technologies. The mission is to move theNation's capabilities beyond the confines of conventional chemical propulsion into an era of aircraft-like access to Earth orbit, rapid travel throughout the solar system, and exploration of interstellar space.
2003-04-09
The Eastman-Kodak mirror assembly is being tested for the James Webb Space Telescope (JWST) project at the X-Ray Calibration Facility at Marshall Space Flight Center (MSFC). In this photo, an MSFC employee is inspecting one of many segments of the mirror assembly for flaws. MSFC is supporting Goddard Space Flight Center (GSFC) in developing the JWST by taking numerous measurements to predict its future performance. The tests are conducted in a vacuum chamber cooled to approximate the super cold temperatures found in space. During its 27 years of operation, the facility has performed testing in support of a wide array of projects, including the Hubble Space Telescope (HST), Solar A, Chandra technology development, Chandra High Resolution Mirror Assembly and science instruments, Constellation X-Ray Mission, and Solar X-Ray Imager, currently operating on a Geostationary Operational Environment Satellite. The JWST is NASA's next generation space telescope, a successor to the Hubble Space Telescope, named in honor of NASA's second administrator, James E. Webb. It is scheduled for launch in 2010 aboard an expendable launch vehicle. It will take about 3 months for the spacecraft to reach its destination, an orbit of 940,000 miles in space.
1989-06-03
The Marshall Space Flight Center (MSFC) engineers test fired a 26-foot long, 100,000-pound-thrust solid rocket motor for 30 seconds at the MSFC east test area, the first test firing of the Modified NASA Motor (M-NASA Motor). The M-NASA Motor was fired in a newly constructed stand. The motor is 48-inches in diameter and was loaded with two propellant cartridges weighing a total of approximately 12,000 pounds. The purpose of the test was to learn more about solid rocket motor insulation and nozzle materials and to provide young engineers additional hands-on expertise in solid rocket motor technology. The test is a part of NASA's Solid Propulsion Integrity Program, that is to provide NASA engineers with the techniques, engineering tools, and computer programs to be able to better design, build, and verify solid rocket motors.
Validation of α-Synuclein as a CSF Biomarker for Sporadic Creutzfeldt-Jakob Disease.
Llorens, Franc; Kruse, Niels; Karch, André; Schmitz, Matthias; Zafar, Saima; Gotzmann, Nadine; Sun, Ting; Köchy, Silja; Knipper, Tobias; Cramm, Maria; Golanska, Ewa; Sikorska, Beata; Liberski, Pawel P; Sánchez-Valle, Raquel; Fischer, Andre; Mollenhauer, Brit; Zerr, Inga
2018-03-01
The analysis of cerebrospinal fluid (CSF) biomarkers gains importance in the differential diagnosis of prion diseases. However, no single diagnostic tool or combination of them can unequivocally confirm prion disease diagnosis. Electrochemiluminescence (ECL)-based immunoassays have demonstrated to achieve high diagnostic accuracy in a variety of sample types due to their high sensitivity and dynamic range. Quantification of CSF α-synuclein (a-syn) by an in-house ECL-based ELISA assay has been recently reported as an excellent approach for the diagnosis of sporadic Creutzfeldt-Jakob disease (sCJD), the most prevalent form of human prion disease. In the present study, we validated a commercially available ECL-based a-syn ELISA platform as a diagnostic test for correct classification of sCJD cases. CSF a-syn was analysed in 203 sCJD cases with definite diagnosis and in 445 non-CJD cases. We investigated reproducibility and stability of CSF a-syn and made recommendations for its analysis in the sCJD diagnostic workup. A sensitivity of 98% and a specificity of 97% were achieved when using an optimal cut-off of 820 pg/mL a-syn. Moreover, we were able to show a negative correlation between a-syn levels and disease duration suggesting that CSF a-syn may be a good prognostic marker for sCJD patients. The present study validates the use of a-syn as a CSF biomarker of sCJD and establishes the clinical and pre-analytical parameters for its use in differential diagnosis in clinical routine. Additionally, the current test presents some advantages compared to other diagnostic approaches: it is fast, economic, requires minimal amount of CSF and a-syn levels are stable along disease progression.
NASA Technical Reports Server (NTRS)
Turner, J. E.
1993-01-01
An elastomeric O-ring material is used in the joints of the redesigned solid motors (RSRM's) of the National Space Transportation System (NSTS). The selection of the O-ring material used in the RSRM's was a very thorough process that included efforts by NASA's Marshall Space Flight Center and the Langley Research Center, and the Thiokol Corporation. One of the efforts performed at MSFC was an extensive in-house laboratory test regime to screen potential O-ring materials and ultimately to characterize the elastomeric material that was chosen to be used in the RSRM's. The laboratory tests performed at MSFC are summarized.
Development of Liquid Propulsion Systems Testbed at MSFC
NASA Technical Reports Server (NTRS)
Alexander, Reginald; Nelson, Graham
2016-01-01
As NASA, the Department of Defense and the aerospace industry in general strive to develop capabilities to explore near-Earth, Cis-lunar and deep space, the need to create more cost effective techniques of propulsion system design, manufacturing and test is imperative in the current budget constrained environment. The physics of space exploration have not changed, but the manner in which systems are developed and certified needs to change if there is going to be any hope of designing and building the high performance liquid propulsion systems necessary to deliver crew and cargo to the further reaches of space. To further the objective of developing these systems, the Marshall Space Flight Center is currently in the process of formulating a Liquid Propulsion Systems testbed, which will enable rapid integration of components to be tested and assessed for performance in integrated systems. The manifestation of this testbed is a breadboard engine configuration (BBE) with facility support for consumables and/or other components as needed. The goal of the facility is to test NASA developed elements, but can be used to test articles developed by other government agencies, industry or academia. Joint government/private partnership is likely the approach that will be required to enable efficient propulsion system development. MSFC has recently tested its own additively manufactured liquid hydrogen pump, injector, and valves in a BBE hot firing. It is rapidly building toward testing the pump and a new CH4 injector in the BBE configuration to demonstrate a 22,000 lbf, pump-fed LO2/LCH4 engine for the Mars lander or in-space transportation. The value of having this BBE testbed is that as components are developed they may be easily integrated in the testbed and tested. MSFC is striving to enhance its liquid propulsion system development capability. Rapid design, analysis, build and test will be critical to fielding the next high thrust rocket engine. With the maturity of the BBE testbed, MSFC propulsion engineering will bring forward a national capability that enables growth of both commercial and government interests.
1967-11-01
Workmen at the Kennedy Space Center position the nose cone for the 204LM-1, an unmanned Apollo mission that tested the Apollo Lunar Module (LM) in Earth orbit. Also known as Apollo 5, the spacecraft was launched on the fourth Saturn IBC launch vehicle. Developed by the Marshall Space Flight Center (MSFC) as an interim vehicle in MSFC's "building block" approach to the Saturn rocket development, the Saturn IBC utilized Saturn I technology to further develop and refine a larger booster and the Apollo spacecraft capabilities required for the manned lunar missions.
Non-Nuclear Testing of Fission Technologies at NASA MSFC
NASA Technical Reports Server (NTRS)
Houts, Robert G.; Pearson, J. Boise; Aschenbrenner, Kenneth C.; Bradley, David E.; Dickens, Ricky E.; Emrich, William J.; Garber, Anne E.; Godfroy, Thomas J.; Harper, Roger T.; Martin, Jim J.;
2011-01-01
Highly realistic non-nuclear testing can be used to investigate and resolve potential issues with space nuclear power and propulsion systems. Non-nuclear testing is particularly useful for systems designed with fuels and materials operating within their demonstrated nuclear performance envelope. Non-nuclear testing also provides an excellent way for screening potential advanced fuels and materials prior to nuclear testing, and for investigating innovative geometries and operating regimes. Non-nuclear testing allows thermal hydraulic, heat transfer, structural, integration, safety, operational, performance, and other potential issues to be investigated and resolved with a greater degree of flexibility and at reduced cost and schedule compared to nuclear testing. The primary limit of non-nuclear testing is that nuclear characteristics and potential nuclear issues cannot be directly investigated. However, non-nuclear testing can be used to augment the potential benefit from any nuclear testing that may be required for space nuclear system design and development. This paper describes previous and ongoing non-nuclear testing related to space nuclear systems at NASA s Marshall Space Flight Center (MSFC).
32. VIEW LOOKING EAST AT THE STATIC TEST TOWER WHILE ...
32. VIEW LOOKING EAST AT THE STATIC TEST TOWER WHILE A JUPITER MISSILE IS BEING POSITIONED ONTO THE TEST TOWER. DATE AND PHOTOGRAPHER UNKNOWN, MSFC PHOTO LAB. - Marshall Space Flight Center, Saturn Propulsion & Structural Test Facility, East Test Area, Huntsville, Madison County, AL
Hazelton, Sandra G.; Zheng, Xingwang; Zhao, Julia Xiaojun; Pierce, David T.
2008-01-01
A variety of recent developments and applications of electrogenerated chemiluminescence (ECL) for sensors are described. While tris(2,2′-bipyridyl)-ruthenium(II) and luminol have dominated and continue to pervade the field of ECL-based sensors, recent work has focused on use of these lumophores with micro- and nanomaterials. It has also extended to inherently luminescent nanomaterials, such as quantum dots. Sensor configurations including microelectrode arrays and microfluidics are reviewed and, with the recent trend toward increased use of nanomaterials, special attention has been given to sensors which include thin films, nanoparticles and nanotubes. Applications of ECL labels and examples of label-free sensing that incorporate nanomaterials are also discussed. PMID:27873850
Development and application of contamination technology for MSFC managed space systems
NASA Technical Reports Server (NTRS)
1993-01-01
The second annual report on the development and application of contamination technology for MSFC managed space systems covering the period from 10 Dec. 1992 to 10 Dec. 1993 is presented. During this time period, studies were concluded which proved that in-process corrosion protection is not required during Redesigned Solid Rocket Motor (RSRM) case processing. Also completed were a series of tests evaluating the effects of environmental exposure and contamination on 2219-T87 aluminum (Space Shuttle External Tank) OSEE response and bonding properties. Correlations were developed between OSEE response, contamination type/level, and primer adhesion. The results showed that the wet tape and water break free tests currently employed during ET processing may not detect bond affecting levels of some potential contaminants; however, the contaminants were detected with OSEE analysis. Finally, exposure/contamination studies were initiated with HP9-4-30 steel. HP9-4-30 was selected for evaluation because it represents a class of metals commom to MSFC managed space flight systems which are less prone to oxidation than D6AC steel or aluminum.
Interplanetary Radiation and Fault Tolerant Mini-Star Tracker System
NASA Technical Reports Server (NTRS)
Rakoczy, John; Paceley, Pete
2015-01-01
The Charles Stark Draper Laboratory, Inc. is partnering with the NASA Marshall Space Flight Center (MSFC) Engineering Directorate's Avionics Design Division and Flight Mechanics & Analysis Division to develop and test a prototype small, low-weight, low-power, radiation-hardened, fault-tolerant mini-star tracker (fig. 1). The project is expected to enable Draper Laboratory and its small business partner, L-1 Standards and Technologies, Inc., to develop a new guidance, navigation, and control sensor product for the growing small sat technology market. The project also addresses MSFC's need for sophisticated small sat technologies to support a variety of science missions in Earth orbit and beyond. The prototype star tracker will be tested on the night sky on MSFC's Automated Lunar and Meteor Observatory (ALAMO) telescope. The specific goal of the project is to address the need for a compact, low size, weight, and power, yet radiation hardened and fault tolerant star tracker system that can be used as a stand-alone attitude determination system or incorporated into a complete attitude determination and control system for emerging interplanetary and operational CubeSat and small sat missions.
1988-01-01
This photograph shows an overall view of the Marshall Space Flight Center's (MSFC's) 14x14-Inch Trisonic Wind Tunnel. The 14-Inch Wind Tunnel is a trisonic wind tunnel. This means it is capable of running subsonic, below the speed of sound; transonic, at or near the speed of sound (Mach 1, 760 miles per hour at sea level); or supersonic, greater than Mach 1 up to Mach 5. It is an intermittent blowdown tunnel that operates by high pressure air flowing from storage to either vacuum or atmospheric conditions. The MSFC 14x14-Inch Trisonic Wind Tunnel has been an integral part of the development of the United States space program Rocket and launch vehicles from the Jupiter-C in 1958, through the Saturn family up to the current Space Shuttle and beyond have been tested in this Wind Tunnel. MSFC's 14x14-Inch Trisonic Wind Tunnel, as with most other wind tunnels, is named after the size of the test section. The 14-Inch Wind Tunnel, as in the past, will continue to play a large but unseen role in the development of America's space program.
1999-04-20
NASA's Space Optics Manufacturing Technology Center has been working to expand our view of the universe via sophisticated new telescopes. The Optics Center's goal is to develop low-cost, advanced space optics technologies for the NASA program in the 21st century, including the long-term goal of imaging Earth-like planets in distant solar systems. A segmented array of mirrors was designed by the Space Optics Manufacturing Technology Center for the solar concentrator test stand at the Marshall Space Flight Center (MSFC) for powering solar thermal propulsion engines. Each hexagon mirror has a spherical surface to approximate a parabolic concentrator when combined into the entire 18-foot diameter array. The aluminum mirrors were polished with a diamond turning machine that creates a glass-like reflective finish on metal. The precision fabrication machinery at the Space Optics Manufacturing Technology Center at MSFC can polish specialized optical elements to a world class quality of smoothness. This image shows optics physicist, Vince Huegele, examining one of the 144-segment hexagonal mirrors of the 18-foot diameter array at the MSFC solar concentrator test stand.
1999-04-20
NASA's Space Optics Manufacturing Technology Center has been working to expand our view of the universe via sophisticated new telescopes. The Optics Center's goal is to develop low-cost, advanced space optics technologies for the NASA program in the 21st century, including the long-term goal of imaging Earth-like planets in distant solar systems. A segmented array of mirrors was designed by the Space Optics Manufacturing Technology Center for solar the concentrator test stand at the Marshall Space Flight Center (MSFC) for powering solar thermal propulsion engines. Each hexagon mirror has a spherical surface to approximate a parabolic concentrator when combined into the entire 18-foot diameter array. The aluminum mirrors were polished with a diamond turning machine, that creates a glass-like reflective finish on metal. The precision fabrication machinery at the Space Optics Manufacturing Technology Center at MSFC can polish specialized optical elements to a world class quality of smoothness. This image shows optics physicist, Vince Huegele, examining one of the 144-segment hexagonal mirrors of the 18-foot diameter array at the MSFC solar concentrator test stand.
Development and application of contamination technology for MSFC managed space systems
NASA Astrophysics Data System (ADS)
The second annual report on the development and application of contamination technology for MSFC managed space systems covering the period from 10 Dec. 1992 to 10 Dec. 1993 is presented. During this time period, studies were concluded which proved that in-process corrosion protection is not required during Redesigned Solid Rocket Motor (RSRM) case processing. Also completed were a series of tests evaluating the effects of environmental exposure and contamination on 2219-T87 aluminum (Space Shuttle External Tank) OSEE response and bonding properties. Correlations were developed between OSEE response, contamination type/level, and primer adhesion. The results showed that the wet tape and water break free tests currently employed during ET processing may not detect bond affecting levels of some potential contaminants; however, the contaminants were detected with OSEE analysis. Finally, exposure/contamination studies were initiated with HP9-4-30 steel. HP9-4-30 was selected for evaluation because it represents a class of metals commom to MSFC managed space flight systems which are less prone to oxidation than D6AC steel or aluminum.
Manufacturing and NDE of Large Composite Structures for Space Transportation at MSFC
NASA Technical Reports Server (NTRS)
McGill, Preston; Russell, Sam
2000-01-01
This paper presents the Marshall Space Flight Center's (MSFC's) vision to manufacture, increase safety and reduce the cost of launch vehicles. Nondestructive evaluations of large composite structures are tested for space transportation at MSFC. The topics include: 1) 6 1/2 Generations of Airplanes in a Century; 2) Shuttle Safety Upgrades; 3) Generations of Reusable Launch Vehicles; 4) RLV Technology Demonstration Path; 5) Second Generation; 6) Key NASA Requirements; 7) X-33 Elements; 8) Future-X Pathfinder Projects and Experiments; 9) Focus Area Technical Goals; 10) X-34 Expanded View; 11) X-38 Spacecraft with De-Orbit Propulsion Stage (DPS); 12) Deorbit Module (DM) Critical Design Review (CDR) Design; 13) Forward Structural Adapter (FSA) CDR Design; 14) X-38 DPS CDR Design; 15) RLV Focused Propulsion Technologies; and 16) Challenges in Technology. This paper is presented in viewgraph form.
Girls' and Boys' Mathematics Achievement, Affect, and Experiences: Findings from ECLS-K
ERIC Educational Resources Information Center
Lubienski, Sarah T.; Robinson, Joseph P.; Crane, Corinna C.; Ganley, Colleen M.
2013-01-01
Amid debates about the continued salience of gender in mathematics, this report summarizes an IES-funded investigation of gender-related patterns in the Early Childhood Longitudinal Study-Kindergarten Class of 1998-99 (ECLS-K). Girls' and boys' mathematics achievement, confidence, and interest were examined, along with experiences at home and…
Parent Involvement and Science Achievement: A Latent Growth Curve Analysis
ERIC Educational Resources Information Center
Johnson, Ursula Yvette
2011-01-01
This study examined science achievement growth across elementary and middle school and parent school involvement using the Early Childhood Longitudinal Study-Kindergarten Class of 1998-1999 (ECLS-K). The ECLS-K is a nationally representative kindergarten cohort of students from public and private schools who attended full-day or half-day…
Guo, Longhua; Yang, Huanghao; Qiu, Bin; Xiao, Xueyang; Xue, Linlin; Kim, Donghwan; Chen, Guonan
2009-12-01
A capillary electrophoresis coupled with electrochemiluminescent detection system (CE-ECL) was developed for the detection of polymerase chain reaction (PCR) amplicons. The ECL luminophore, tris(1,10-phenanthroline) ruthenium(II) (Ru(phen)(3)(2+)), was labeled to the PCR primers before amplification. Ru(phen)(3)(2+) was then introduced to PCR amplicons by PCR amplification. Eventually, the PCR amplicons were separated and detected by the homemade CE-ECL system. The detection of a typical genetically modified organism (GMO), Roundup Ready Soy (RRS), was shown as an example to demonstrate the reliability of the proposed approach. Four pairs of primers were amplified by multiple PCR (MPCR) simultaneously, three of which were targeted on the specific sequence of exogenous genes of RRS, and another was targeted on the endogenous reference gene of soybean. Both the conditions for PCR amplification and CE-ECL separation and detection were investigated in detail. Results showed that, under the optimal conditions, the proposed method can accurately identifying RRS. The corresponding limit of detection (LOD) was below 0.01% with 35 PCR cycles.
Study on a Luminol-based Electrochemiluminescent Sensor for Label-Free DNA Sensing
Chu, Hai-Hong; Yan, Ji-Lin; Tu, Yi-Feng
2010-01-01
Automatic, inexpensive, simple and sensitive methods for DNA sensing and quantification are highly desirable for biomedical research. The rapid development of both the fundamentals and applications of electrochemiluminescence (ECL) over the past years has demonstrated its potential for analytical and bio-analytical chemistry. This paper reports the quenching effect of DNA on the ECL of luminol and the further development of a DNA sensing device. With the pre-functionalization by a composite of carbon nano-tubes (CNTs) and Au nanoparticles (AuNPs), the sensor provides a novel and valuable label-free approach for DNA sensing. Here the ECL intensity was remarkably decreased when more than 1.0 × 10−12 molar of DNA were adsorbed on the sensor. Linearity of the DNA amount with the reciprocal of ECL intensity was observed. A saturated sensor caused a 92.8% quenching effect. The research also proposes the mechanism for the quenching effect which could be attributed to the interaction between luminol and DNA and the elimination of reactive oxygen species (ROSs) by DNA. PMID:22163421
Yu, Zhimin; Wei, Xiuhua; Yan, Jilin; Tu, Yifeng
2012-04-21
With TiO(2) nanoparticles as carrier, a supported nano-material of Au atomic cluster/TiO(2) nano-hybrid was synthesized. It was then modified onto the surface of indium tin oxide (ITO) by Nafion to act as a working electrode for exciting the electrochemiluminescence (ECL) of luminol. The properties of the nano-hybrid and the modified electrode were characterized by XRD, XPS, electronic microscopy, electrochemistry and spectroscopy. The experimental results demonstrated that the modification of this nano-hybrid onto the ITO electrode efficiently intensified the ECL of luminol. It was also revealed that the ECL intensity of luminol on this modified electrode showed very sensitive responses to oxygen and hydrogen peroxide. The detection limits for dissolved oxygen and hydrogen peroxide were 2 μg L(-1) and 5.5 × 10(-12) M, respectively. Besides the discussion of the intensifying mechanism of this nano-hybrid for ECL of luminol, the developed method was also applied for monitoring dissolved oxygen and evaluating the scavenging efficiency of reactive oxygen species of the Ganoderma lucidum spore.
NASA Astrophysics Data System (ADS)
Su, Qiang; Zhou, Xiaoming
2008-12-01
Many pathogenic and genetic diseases are associated with changes in the sequence of particular genes. We describe here a rapid and highly efficient assay for the detection of point mutation. This method is a combination of isothermal rolling circle amplification (RCA) and high sensitive electrochemluminescence (ECL) detection. In the design, a circular template generated by ligation upon the recognition of a point mutation on DNA targets was amplified isothermally by the Phi29 polymerase using a biotinylated primer. The elongation products were hybridized with tris (bipyridine) ruthenium (TBR)-tagged probes and detected in a magnetic bead based ECL platform, indicating the mutation occurrence. P53 was chosen as a model for the identification of this method. The method allowed sensitive determination of the P53 mutation from wild-type and mutant samples. The main advantage of RCA-ECL is that it can be performed under isothermal conditions and avoids the generation of false-positive results. Furthermore, ECL provides a faster, more sensitive, and economical option to currently available electrophoresis-based methods.
Li, Lingling; Chen, Ying; Lu, Qian; Ji, Jing; Shen, Yuanyuan; Xu, Mi; Fei, Rong; Yang, Guohai; Zhang, Kui; Zhang, Jian-Rong; Zhu, Jun-Jie
2013-01-01
The marriage of energy transfer with electrochemiluminescence has produced a new technology named electrochemiluminescence energy transfer (ECL-ET), which can realize effective and sensitive detection of biomolecules. To obtain optimal ECL-ET efficiency, perfect energy overlapped donor/acceptor pair is of great importance. Herein, we present a sensitive ECL-ET based immunosensor for the detection of tumor markers, using energy tunable CdSeTe/CdS/ZnS double shell quantum dots (QDs) and gold nanorods (GNRs) as the donor and acceptor, respectively. Firstly a facile microwave-assisted strategy for the synthesis of green- to near-infrared-emitting CdSeTe/CdS/ZnS QDs with time- and component-tunable photoluminescence was proposed. And, on the basis of the adjustable optical properties of both CdSeTe/CdS/ZnS QDs and GNRs, excellent overlap between donor emission and acceptor absorption can be obtained to ensure effective ECL-ET quenching, thus improving the sensing sensitivity. This method represents a novel approach for versatile detection of biomolecules at low concentrations. PMID:23524874
NASA Astrophysics Data System (ADS)
Beier, Ross C.; Young, Colin R.; Stanker, Larry H.
1999-01-01
A competitive exclusion (CE) culture of chicken cecal anaerobes has been developed and used in this laboratory for control of Salmonella typhimurium in chickens. The CE culture consists of 29 different species of micro-organisms, and is known as CF3. Detection of one of the CF3 bacteria, Eubacteria, and S. typhimurium were demonstrated using a commercial immunomagnetic (IM) electrochemiluminescence (ECL) sensor, the ORIGENR Analyzer. Analysis was achieved using a sandwich immunoassay. Bacteria were captured on antibody- conjugated 280 micron sized magnetic beads followed by binding of reporter antibodies labelled with ruthenium (II) tris(dipyridyl) chelate [Ru(bpy)32+]. The magnetic beads were then trapped on an electrode in the reaction cell of the ORIGENR Analyzer by a magnet, and the ECL was evoked from Ru(bpy)32+ on the tagged reporter antibodies by an electrical potential at the electrode. Preliminary IM-ECL assays with Eubacteria yielded a detection limit of 105 cfu/mL. Preliminary IM-ECL assays with S. typhimurium yielded a similar detection limit of 105 cfu/mL.
Structure prediction of the second extracellular loop in G-protein-coupled receptors.
Kmiecik, Sebastian; Jamroz, Michal; Kolinski, Michal
2014-06-03
G-protein-coupled receptors (GPCRs) play key roles in living organisms. Therefore, it is important to determine their functional structures. The second extracellular loop (ECL2) is a functionally important region of GPCRs, which poses significant challenge for computational structure prediction methods. In this work, we evaluated CABS, a well-established protein modeling tool for predicting ECL2 structure in 13 GPCRs. The ECL2s (with between 13 and 34 residues) are predicted in an environment of other extracellular loops being fully flexible and the transmembrane domain fixed in its x-ray conformation. The modeling procedure used theoretical predictions of ECL2 secondary structure and experimental constraints on disulfide bridges. Our approach yielded ensembles of low-energy conformers and the most populated conformers that contained models close to the available x-ray structures. The level of similarity between the predicted models and x-ray structures is comparable to that of other state-of-the-art computational methods. Our results extend other studies by including newly crystallized GPCRs. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Gauthier, J. J.; Roman, M. C.; Kilgore, B. A.; Huff, T. L.; Obenhuber, D. C.; Terrell, D. W.; Wilson, M. E.; Jackson, N. E.
1991-01-01
NASA/MSFC is developing a physical/chemical treatment system to reclaim wastewater for reuse on Space Station Freedom (SSF). Integrated testing of hygiene and potable water subsystems assessed the capability to reclaim water to SSF specifications. The test was conducted from May through July 1990 with a total of 47 days of system test operation. Water samples were analyzed using standard cultural methods employing membrane filtration and spread plate techniques and epifluorescence microscopy. Fatty acid methyl ester and biochemical profiles were used for microbial identification. Analysis of waste and product water produced by the subsystems demonstrated the effective reduction of viable microbial populations greater than 8.0E + 06 colony forming units (CFU) per 100 mL to an average of 5 CFU/100 mL prior to distribution into storage tanks.
Nozzle Side Load Testing and Analysis at Marshall Space Flight Center
NASA Technical Reports Server (NTRS)
Ruf, Joseph H.; McDaniels, David M.; Brown, Andrew M.
2009-01-01
Realistic estimates of nozzle side loads, the off-axis forces that develop during engine start and shutdown, are important in the design cycle of a rocket engine. The estimated magnitude of the nozzle side loads has a large impact on the design of the nozzle shell and the engine s thrust vector control system. In 2004 Marshall Space Flight Center (MSFC) began developing a capability to quantify the relative magnitude of side loads caused by different types of nozzle contours. The MSFC Nozzle Test Facility was modified to measure nozzle side loads during simulated nozzle start. Side load results from cold flow tests on two nozzle test articles, one with a truncated ideal contour and one with a parabolic contour are provided. The experimental approach, nozzle contour designs and wall static pressures are also discussed
1976-01-06
At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was originally designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage. Modifications to the S-IC Test Stand began in 1975 to accommodate space shuttle external tank testing. This photo is of the horizontal liquid oxygen tanks.
Cold Flow Propulsion Test Complex Pulse Testing
NASA Technical Reports Server (NTRS)
McDougal, Kris
2016-01-01
When the propellants in a liquid rocket engine burn, the rocket not only launches and moves in space, it causes forces that interact with the vehicle itself. When these interactions occur under specific conditions, the vehicle's structures and components can become unstable. One instability of primary concern is termed pogo (named after the movement of a pogo stick), in which the oscillations (cycling movements) cause large loads, or pressure, against the vehicle, tanks, feedlines, and engine. Marshall Space Flight Center (MSFC) has developed a unique test technology to understand and quantify the complex fluid movements and forces in a liquid rocket engine that contribute strongly to both engine and integrated vehicle performance and stability. This new test technology was established in the MSFC Cold Flow Propulsion Test Complex to allow injection and measurement of scaled propellant flows and measurement of the resulting forces at multiple locations throughout the engine.
Robotic Lunar Landers for Science and Exploration
NASA Technical Reports Server (NTRS)
Chavers, D. G.; Cohen, B. A.; Bassler, J. A.; Hammond, M. S.; Harris, D. W.; Hill, L. A.; Eng, D.; Ballard, B. W.; Kubota, S. D.; Morse, B. J.;
2010-01-01
NASA Marshall Space Flight Center (MSFC) and The Johns Hopkins University Applied Physics Laboratory (APL) have been conducting mission studies and performing risk reduction activities for NASA s robotic lunar lander flight projects. This paper describes some of the lunar lander concepts derived from these studies conducted by the MSFC/APL Robotic Lunar Lander Development Project team. In addition, the results to date of the lunar lander development risk reduction efforts including high pressure propulsion system testing, structure and mechanism development and testing, long cycle time battery testing and combined GN&C and avionics testing will be addressed. The most visible elements of the risk reduction program are two autonomous lander flight test vehicles: a compressed air system with limited flight durations and a second version using hydrogen peroxide propellant to achieve significantly longer flight times and the ability to more fully exercise flight sensors and algorithms.
NASA Technical Reports Server (NTRS)
Scholl, R. E. (Editor)
1979-01-01
Earthquake engineering research capabilities of the National Aeronautics and Space Administration (NASA) facilities at George C. Marshall Space Flight Center (MSFC), Alabama, were evaluated. The results indicate that the NASA/MSFC facilities and supporting capabilities offer unique opportunities for conducting earthquake engineering research. Specific features that are particularly attractive for large scale static and dynamic testing of natural and man-made structures include the following: large physical dimensions of buildings and test bays; high loading capacity; wide range and large number of test equipment and instrumentation devices; multichannel data acquisition and processing systems; technical expertise for conducting large-scale static and dynamic testing; sophisticated techniques for systems dynamics analysis, simulation, and control; and capability for managing large-size and technologically complex programs. Potential uses of the facilities for near and long term test programs to supplement current earthquake research activities are suggested.
Cloning and expression of sheep renal K-CI cotransporter-1.
Zhang, Jin J; Misri, Sandeep; Adragna, Norma C; Gagnon, Kenneth B E; Fyffe, Robert E W; Lauf, Peter K
2005-01-01
Sheep K-Cl cotransporter-1(shKCC1) cDNA was cloned from kidney by RT-PCR with an open reading frame of 3258 base pairs exhibiting 92%, 90%, 88% and 87% identity with pig, rabbit and human, rat and mouse KCC1 cDNAs, respectively, encoding an approximately 122 kDa polypeptide of 1086-amino acids. Hydropathy analysis reveals the familiar KCC1 topology with 12 transmembrane domains (TMDs) and the hydrophilic NH2-terminal (NTD) and COOH-terminal (CTD) domains both at the cytoplasmic membrane face. However, shKCC1 has two rather than one large extracellular loops (ECL): ECL3 between TMDs 5 and 6, and ECL6, between TMDs 11 and 12. The translated shKCC1 protein differs in 12 amino acid residues from other KCC1s, mainly within the NTD, ECL3, ICL4, ECL6, and CTD. Notably, a tyrosine residue at position 996 replaces aspartic acid conserved in all other species. Human embryonic kidney (HEK293) cells and mouse NIH/3T3 fibroblasts, transiently transfected with shKCCI-cDNA, revealed the glycosylated approximately 150 kDa proteins by Western blots and positive immunofluorescence-staining with polyclonal rabbit anti-ratKCC1 antibodies. ShKCC1 was functionally expressed in NIH/3T3 cells by an elevated basal Cl-dependent K influx measured with Rb as K-congener that was stimulated three-fold by the KCC-activator N-ethylmaleimide. Copyright (c) 2005 S. Karger AG, Basel.
Zhang, Wenzhu; Zhang, Jingmei; Zhang, Hailei; Cao, Liyan; Zhang, Run; Ye, Zhiqiang; Yuan, Jingli
2013-11-15
A ruthenium(II) complex, [Ru(bpy)2(DA-phen)](PF6)2 (bpy: 2,2'-bipyridine; DA-phen: 5,6-diamino-1,10-phenanthroline), has been developed as a photoluminescent (PL) and electrochemiluminescent (ECL) dual-signaling probe for the highly sensitive and selective detection of nitric oxide (NO) in aqueous and biological samples. Due to the presence of electron transfer process from diamino group to the excited-state of the Ru(II) complex, the PL and ECL intensities of the probe are very weak. After the probe was reacted with NO in physiological pH aqueous media under aerobic conditions to afford its triazole derivative, [Ru(bpy)2(TA-phen)](2+) (TA-phen: 5,6-triazole-1,10-phenanthroline), the electron transfer process was inhibited, so that the PL and ECL efficiency of the Ru(II) complex was remarkably increased. The PL and ECL responses of the probe to NO in physiological pH media are highly sensitive with the detection limits at low micromolar concentration level, and highly specific without the interferences of other reactive oxygen/nitrogen species (ROS/RNS) and metal ions. Moreover, the probe has good cell-membrane permeability, and can be rapidly transferred into living cells for trapping the intracellular NO molecules. These features enabled the probe to be successfully used for the monitoring of the endogenous NO production in living biological cell and tissue samples with PL and ECL dual-modes. Copyright © 2013 Elsevier B.V. All rights reserved.
Wei, Yanfen; Wang, Hao; Sun, Shuangjiao; Tang, Lifu; Cao, Yupin; Deng, Biyang
2016-12-15
A new electrochemiluminescence (ECL) sensor based on reduced graphene oxide-copper sulfide (rGO-CuS) composite coupled with capillary electrophoresis (CE) was constructed for the ultrasensitive detection of amlodipine besylate (AML) for the first time. In this work, rGO-CuS composite was synthesized by one-pot hydrothermal method and used for electrode modification. The electrochemical and ECL behaviors of the sensor were investigated. More than 5-fold enhance in ECL intensity was observed after modified with rGO-CuS composite. The results can be ascribed to the presence of rGO-CuS composite on the electrode surface that facilitates the electron transfer rate between the electroactive center of Ru(bpy)3(2+) and the electrode. The ECL sensor was coupled with CE to improve the selectivity and the CE-ECL parameters that affect separation and detection were optimized. Under the optimum conditions, the linear ranges for AML was 0.008-5.0μg/mL with a detection limit of 2.8ng/mL (S/N=3). The method displayed the advantages of high sensitivity, good selectivity, wide linear range, low detection limit and fine reproducibility, and was used to analyze AML in mice plasma with a satisfactory result, which holds a great potential in the field of pharmaceutical analysis. Copyright © 2016 Elsevier B.V. All rights reserved.
Qiu, Bin; Xue, Lingling; Wu, Yanping; Lin, Zhenyu; Guo, Longhua; Chen, Guonan
2011-07-15
Inhibited Ru(bpy)(3)(2+) electrochemiluminescence by inorganic oxidants is investigated. Results showed that a number of inorganic oxidants can quench the ECL of Ru(bpy)(3)(2+)/tri-n-propylamine (TPrA) system, and the logarithm of the decrease in ECL intensity (ΔI) was proportional to the logarithm of analyte concentrations. Based on which, a sensitive approach for detection of these inorganic oxidants was established, e.g. the log-log plots of ΔI versus the concentration of MnO(4)(-), Cr(2)O(7)(2-) and Fe(CN)(6)(3-) are linear in the range of 1×10(-7) to 3×10(-4)M for MnO(4)(-) and Cr(2)O(7)(2-), and 1×10(-7) to 1×10(-4)M for Fe(CN)(6)(3-), with the limit of detection (LOD) of 8.0×10(-8)M, 2×10(-8)M, and 1×10(-8)M, respectively. A series of experiments such as a comparison of the inhibitory effect of different compounds on Ru(bpy)(3)(2+)/TPrA ECL, ECL emission spectra, UV-Vis absorption spectra etc. were investigated in order to discover how these inorganic analytes quench the ECL of Ru(bpy)(3)(2+)/TPrA system. A mechanism based on consumption of TPrA intermediate (TPrA(·)) by inorganic oxidants was proposed. Copyright © 2011 Elsevier B.V. All rights reserved.
ROBERT BOBO AND MIKE NICHOLS AT TEST STAND 4693
2016-12-14
ROBERT BOBO, LEFT, AND MIKE NICHOLS TALK BENEATH THE 221-FOOT-TALL TEST STAND 4693, THE LARGEST OF TWO NEW SPACE LAUNCH SYSTEM TEST STANDS AT MSFC. BOBO MANAGES SLS STRUCTURAL STRENGTH TESTING, AND NICHOLS IS LEAD TEST ENGINEER FOR THE SLS LIQUID HYDROGEN TANK.
When all else fails: extracorporeal life support in therapy-refractory cardiogenic shock.
Guenther, Sabina P W; Brunner, Stefan; Born, Frank; Fischer, Matthias; Schramm, René; Pichlmaier, Maximilian; Massberg, Steffen; Hagl, Christian; Khaladj, Nawid
2016-03-01
No guidelines for mechanical circulatory support in patients with therapy-refractory cardiogenic shock and multiorgan failure including ongoing cardiopulmonary resuscitation (CPR) exist. To achieve immediate cardiopulmonary stabilization, we established an interdisciplinary concept with on-site percutaneous extracorporeal life support (ECLS) implantation. From February 2012 to November 2014, 96 patients were deemed eligible for ECLS implantation. Establishing ECLS was successful in 87 patients (mean age 54 ± 13 years, 16% female, initial flow 4.4 ± 0.9 l/min). Aetiologies included acute coronary syndromes (n = 52, 60%), cardiomyopathies (n = 25, 29%) and other pathologies. Fifty-nine patients (68%) had been resuscitated, and in 27 (31%), implantation was performed during CPR; 11 patients (13%) were awake at implantation and 20 (23%) underwent implantation in the referring hospital. Metabolic parameters differed in non-survivors versus survivors before ECLS implantation (pH 7.15 ± 0.23 vs. 7.27 ± 0.18, P = 0.007; lactate levels 10.90 ± 6.00 mmol/l vs. 8.79 ± 5.78 mmol/l, P = 0.091) and 6 h postimplantation (pH 7.27 ± 0.11 vs. 7.37 ± 0.11, P < 0.001; lactate levels 10.19 ± 5.52 mmol/l vs. 5.52 ± 4.17 mmol/l, P < 0.001). Altogether 44 patients could be weaned, and 9 were bridged to assist device implantation and 1 to heart transplantation. The mean time of support was 6 days, and the 30-day survival rate was 47% (n = 41). ECLS serves as a bridge-to-decision and bridge-to-treatment device. Our interdisciplinary ECLS programme achieved acceptable survival of critically ill patients despite a substantial percentage of patients having been resuscitated and no absolute exclusion criteria. Further studies defining inclusion- and exclusion criteria might additionally improve outcome. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Feng, Xiaobin; Gan, Ning; Zhang, Huairong; Yan, Qing; Li, Tianhua; Cao, Yuting; Hu, Futao; Yu, Hongwei; Jiang, Qianli
2015-12-15
A novel type of "dual-potential" electrochemiluminescence (ECL) aptasensor array was fabricated on a homemade screen-printed carbon electrode (SPCE) for simultaneous detection of malachite green (MG) and chloramphenicol (CAP) in one single assay. The SPCE substrate consisted of a common Ag/AgCl reference electrode, carbon counter electrode and two carbon working electrodes (WE1 and WE2). In the system, CdS quantum dots (QDs) were modified on WE1 as cathode ECL emitters and luminol-gold nanoparticles (L-Au NPs) were modified on WE2 as anode ECL emitters. Then the MG aptamer complementary strand (MG cDNA) and CAP aptamer complementary strand (CAP cDNA) were attached on CdS QDs and L-Au NPs, respectively. The cDNA would hybridize with corresponding aptamer that was respectively tagged with cyanine dye (Cy5) (as quenchers of CdS QDs) and chlorogenic acid (CA) (as quenchers of l-Au NPs) using poly(ethylenimine) (PEI) as a bridging agent. PEI could lead to a large number of quenchers on the aptamer, which increased the quenching efficiency. Upon MG and CAP adding, the targets could induce strand release due to the highly affinity of analytes toward aptamers. Meanwhile, it could release the Cy5 and CA, which recovered cathode ECL of CdS QDs and anode ECL of L-Au NPs simultaneously. This "dual-potential" ECL strategy could be used to detect MG and CAP with the linear ranges of 0.1-100 nM and 0.2-150 nM, with detection limits of 0.03 nM and 0.07 nM (at 3sB), respectively. More importantly, this designed method was successfully applied to determine MG and CAP in real fish samples and held great potential in the food analysis. Copyright © 2015 Elsevier B.V. All rights reserved.
Jiang, Xinya; Wang, Huijun; Wang, Haijun; Yuan, Ruo; Chai, Yaqin
2016-09-20
In the present work, we first found that mercury ion (Hg(2+)) has an efficient quenching effect on the electrochemiluminescence (ECL) of N-(aminobutyl)-N-(ethylisoluminol) (ABEI). Since we were inspired by this discovery, an aptamer-based ECL sensor was fabricated based on a Hg(2+) triggered signal switch coupled with an exonuclease I (Exo I)-stimulated target recycling amplification strategy for ultrasensitive determination of Hg(2+) and mucin 1 (MUC1). Concretely, the ECL intensity of ABEI-functionalized silver nanoparticles decorated graphene oxide nanocomposite (GO-AgNPs-ABEI) was initially enhanced by ferrocene labeled ssDNA (Fc-S1) (first signal switch "on" state) in the existence of H2O2. With the aid of aptamer, assistant ssDNA (S2) and full thymine (T) bases ssDNA (S3) modified Au nanoparticles (AuNPs-S2-S3) were immobilized on the sensing surface through the hybridization reaction. Then, via the strong and stable T-Hg(2+)-T interaction, an abundance of Hg(2+) was successfully captured on the AuNPs-S2-S3 and effectively inhibited the ECL reaction of ABEI (signal switch "off" state). Finally, the signal switch "on" state was executed by utilizing MUC1 as an aptamer-specific target to bind aptamer, leading to the large decrease of the captured Hg(2+). To further improve the sensitivity of the aptasensor, Exo I was implemented to digest the binded aptamer, which resulted in the release of MUC1 for achieving target recycling with strong detectable ECL signal even in a low level of MUC1. By integrating the quenching effect of Hg(2+) to reduce the background signal and target recycling for signal amplification, this proposed ECL aptasensor was successfully used to detect Hg(2+) and MUC1 sensitively with a wide linear response.
Members of House Committee on Science and Astronautics Visited MSFC
NASA Technical Reports Server (NTRS)
1962-01-01
The members of the House Committee on Science and Astronautics visited the Marshall Space Flight Center (MSFC) on March 9, 1962 to gather firsthand information of the nation's space exploration program. The congressional group was composed of members of the Subcommittee on Manned Space Flight. They were briefed on MSFC's manned space efforts earlier in the day and then inspected mockups of the Saturn I Workshop and the Apollo Telescope Mount, two projects developed by MSFC for the post-Apollo program. Pictured left-to-right are Dieter Grau, MSFC; Konrad Dannenberg, MSFC; James G. Fulton, Republican representative for Pennsylvania; Joe Waggoner, Democratic representative for Louisiana; and Dr. Wernher von Braun, Director of MSFC.
NASA Technical Reports Server (NTRS)
Osborne, Robin; Wehrmeyer, Joseph; Trinh, Huu; Early, James
2003-01-01
This paper addresses the progress of technology development of a laser ignition system at NASA Marshall Space Flight Center (MSFC). Laser ignition has been used at MSFC in recent test series to successfully ignite RP1/GOX propellants in a subscale rocket chamber, and other past studies by NASA GRC have demonstrated the use of laser ignition for rocket engines. Despite the progress made in the study of this ignition method, the logistics of depositing laser sparks inside a rocket chamber have prohibited its use. However, recent advances in laser designs, the use of fiber optics, and studies of multi-pulse laser formats3 have renewed the interest of rocket designers in this state-of the-art technology which offers the potential elimination of torch igniter systems and their associated mechanical parts, as well as toxic hypergolic ignition systems. In support of this interest to develop an alternative ignition system that meets the risk-reduction demands of Next Generation Launch Technology (NGLT), characterization studies of a dual pulse laser format for laser-induced spark ignition are underway at MSFC. Results obtained at MSFC indicate that a dual pulse format can produce plasmas that absorb the laser energy as efficiently as a single pulse format, yet provide a longer plasma lifetime. In an experiments with lean H2/air propellants, the dual pulse laser format, containing the same total energy of a single laser pulse, produced a spark that was superior in its ability to provide sustained ignition of fuel-lean H2/air propellants. The results from these experiments are being used to optimize a dual pulse laser format for future subscale rocket chamber tests. Besides the ignition enhancement, the dual pulse technique provides a practical way to distribute and deliver laser light to the combustion chamber, an important consideration given the limitation of peak power that can be delivered through optical fibers. With this knowledge, scientists and engineers at Los Alamos National Laboratory and CFD Research Corporation have designed and fabricated a miniaturized, first-generation optical prototype of a laser ignition system that could be the basis for a laser ignition system for rocket applications. This prototype will be tested at MSFC in future subscale rocket ignition tests.
Apollo-Soyuz test project: Composite of MSFC final science report
NASA Technical Reports Server (NTRS)
1977-01-01
Experimental procedures of nine experiments conducted during the Apollo-Soyuz Test Project mission from July 15th to July 24th, 1975 are presented. Conclusions and recommendations based on these experiments are given.
The Effects of Professional Learning Communities on Student Achievement
ERIC Educational Resources Information Center
Burdett, John M.
2009-01-01
The purpose of this study was to examine data from the Early Childhood Longitudinal Study: Kindergarten Class of 1998-99 (ECLS-K) report, identify questions and statements that correlate to the dimensions of professional learning communities (PLCs), and determine the effect PLCs have on student achievement based on the ECLS-K data. In addition,…
Examining ECLS-B: Maternal Stress and Depressive Symptoms when Raising Children with ASD
ERIC Educational Resources Information Center
Jeans, Laurie M.; Santos, Rosa Milagros; Laxman, Daniel J.; McBride, Brent A.; Dyer, W. Justin
2013-01-01
Using the Early Childhood Longitudinal Study-Birth Cohort (ECLS-B), a nationally representative data set, we examined the extent to which mothers of preschool children with and without the diagnosis of an Autism Spectrum Disorder (ASD) reported stress and depressive symptoms prior to and following diagnosis of ASD. At 4 years, approximately 100…
ERIC Educational Resources Information Center
Andreassen, Carol; Fletcher, Philip
2007-01-01
This methodology report documents the design, development, and psychometric characteristics of the assessment instruments used in the second wave of the ECLS-B. The assessment instruments discussed measure children's cognitive development (BSF-R), socioemotional functioning (Two Bags Task), security of attachment (TAS-45), and physical development…
ERIC Educational Resources Information Center
Tourangeau, Karen; Brick, Mike; Byrne, Lauren; Le, Thanh; Nord, Christine; West, Jerry; Hausken, Elvira Germino
2005-01-01
This methodology report provides technical information about the development, design, and conduct of the third grade data collection of the Early Childhood Longitudinal Study, Kindergarten Class of 1998-99 (ECLS-K). Detailed information on the development of the instruments, sample design, data collection methods, data preparation and editing,…
5. PRELIMINARY SKETCH OF THE GUIDED MISSILE TEST FACILITIES FOR ...
5. PRELIMINARY SKETCH OF THE GUIDED MISSILE TEST FACILITIES FOR TEST AREA NUMBER 2. TODAY IR IS KNOWN AS MARSHALL SPACE FLIGHT CENTER'S EAST TEST AREA. HANNES LUEHRSEN COLLECTION, MSFC MASTER PLANNING OFFICE. - Marshall Space Flight Center, East Test Area, Dodd Road, Huntsville, Madison County, AL
International Space Station Environmental Control and Life Support System Status: 2002-2003
NASA Technical Reports Server (NTRS)
Wiliams, David E.; Lewis, John F.; Gentry, Gregory
2003-01-01
The International Space Station (ISS) Environmental Control and Life Support (ECLS) system includes regenerative and non-regenerative technologies that provide the basic life support functions to support the crew, while maintaining a safe and habitable shirtsleeve environment. This paper provides a summary of the U.S. ECLS system activities over the past year, covering the period of time between April 2002 and March 2003. The ISS continued permanent crew operations, with the start of Phase 3 of the ISS Assembly Sequence. Work continued on the Phase 3 pressurized elements with Node 3 just completing its final design review so that it can proceed towards manufacturing and the continued manufacturing of the regenerative ECLS equipment that will be integrated into Node 3.
Comparing NASA and ESA Cost Estimating Methods for Human Missions to Mars
NASA Technical Reports Server (NTRS)
Hunt, Charles D.; vanPelt, Michel O.
2004-01-01
To compare working methodologies between the cost engineering functions in NASA Marshall Space Flight Center (MSFC) and ESA European Space Research and Technology Centre (ESTEC), as well as to set-up cost engineering capabilities for future manned Mars projects and other studies which involve similar subsystem technologies in MSFC and ESTEC, a demonstration cost estimate exercise was organized. This exercise was a direct way of enhancing not only cooperation between agencies but also both agencies commitment to credible cost analyses. Cost engineers in MSFC and ESTEC independently prepared life-cycle cost estimates for a reference human Mars project and subsequently compared the results and estimate methods in detail. As a non-sensitive, public domain reference case for human Mars projects, the Mars Direct concept was chosen. In this paper the results of the exercise are shown; the differences and similarities in estimate methodologies, philosophies, and databases between MSFC and ESTEC, as well as the estimate results for the Mars Direct concept. The most significant differences are explained and possible estimate improvements identified. In addition, the Mars Direct plan and the extensive cost breakdown structure jointly set-up by MSFC and ESTEC for this concept are presented. It was found that NASA applied estimate models mainly based on historic Apollo and Space Shuttle cost data, taking into account the changes in technology since then. ESA used models mostly based on European satellite and launcher cost data, taking into account the higher equipment and testing standards for human space flight. Most of NASA's and ESA s estimates for the Mars Direct case are comparable, but there are some important, consistent differences in the estimates for: 1) Large Structures and Thermal Control subsystems; 2) System Level Management, Engineering, Product Assurance and Assembly, Integration and Test/Verification activities; 3) Mission Control; 4) Space Agency Program Level activities.
The Space Station Module Power Management and Distribution automation test bed
NASA Technical Reports Server (NTRS)
Lollar, Louis F.
1991-01-01
The Space Station Module Power Management And Distribution (SSM/PMAD) automation test bed project was begun at NASA/Marshall Space Flight Center (MSFC) in the mid-1980s to develop an autonomous, user-supportive power management and distribution test bed simulating the Space Station Freedom Hab/Lab modules. As the test bed has matured, many new technologies and projects have been added. The author focuses on three primary areas. The first area is the overall accomplishments of the test bed itself. These include a much-improved user interface, a more efficient expert system scheduler, improved communication among the three expert systems, and initial work on adding intermediate levels of autonomy. The second area is the addition of a more realistic power source to the SSM/PMAD test bed; this project is called the Large Autonomous Spacecraft Electrical Power System (LASEPS). The third area is the completion of a virtual link between the SSM/PMAD test bed at MSFC and the Autonomous Power Expert at Lewis Research Center.
Test Before You Fly - High Fidelity Planetary Environment Simulation
NASA Technical Reports Server (NTRS)
Craven, Paul; Ramachandran, Narayanan; Vaughn, Jason; Schneider, Todd; Nehls, Mary
2012-01-01
The lunar surface environment will present many challenges to the survivability of systems developed for long duration lunar habitation and exploration of the lunar, or any other planetary, surface. Obstacles will include issues pertaining especially to the radiation environment (solar plasma and electromagnetic radiation) and lunar regolith dust. The Planetary Environments Chamber is one piece of the MSFC capability in Space Environmental Effects Test and Analysis. Comprised of many unique test systems, MSFC has the most complete set of SEE test capabilities in one location allowing examination of combined space environmental effects without transporting already degraded, potentially fragile samples over long distances between tests. With this system, the individual and combined effects of the lunar radiation and regolith environment on materials, sub-systems, and small systems developed for the lunar return can be investigated. This combined environments facility represents a unique capability to NASA, in which tests can be tailored to any one aspect of the lunar environment (radiation, temperature, vacuum, regolith) or to several of them combined in a single test.
NASA Technical Reports Server (NTRS)
Johnson, J. D.; Braddock, W. F.
1975-01-01
A force test of a 2.112 percent scale Space Shuttle Solid Rocket Booster (SRB), MSFC Model 454, was conducted in test section no. 2 of the Unitary Plan Wind Tunnel. Sixteen (16) runs (pitch polars) were performed over an angle of attack range from 144 through 179 degrees. Test Mach numbers were 2.30, 2.70, 2.96, 3.48, 4.00 and 4.63. The first three Mach numbers had a test Reynolds number of 1.5 million per foot. The remaining three were at 2.0 million per foot. The model was tested in the following configurations: (1) SRB without external protuberances, and (2) SRB with an electrical tunnel and a SRB/ET thrust attachment structure. Schlieren photographs were taken during the testing of the first configuration. The second configuration was tested at roll angles of 45, 90, and 135 degrees.
30. SKETCH OF THE PROPOSED TEST STAND FOR THE ORDNANCE ...
30. SKETCH OF THE PROPOSED TEST STAND FOR THE ORDNANCE GUIDED MISSILE CENTER AT REDSTONE ARSENAL (PRE-DATING NASA). JUNE, 1951, HANS LUEHRSEN COLLECTION, MSFC MASTER PLANNING OFFICE. - Marshall Space Flight Center, Saturn Propulsion & Structural Test Facility, East Test Area, Huntsville, Madison County, AL
Testing of the Japanese Experimental Module in NBS
NASA Technical Reports Server (NTRS)
1993-01-01
This photograph was taken in the Marshall Space Flight Center (MSFC) Neutral Buoyancy Simulator (NBS) during the testing of the Japanese Experimental Module. The NBS provided the weightless environment encountered in space needed for testing and the practices of extra-vehicular activities.
Hubble Space Telescope nickel-hydrogen battery testing: An update
NASA Technical Reports Server (NTRS)
Whitt, Thomas H.; Brewer, Jeffrey C.
1995-01-01
The Marshall Space Flight Center (MSFC) began testing the HST Ni-H2 Six Battery Test and the 'Flight Spare Battery' Tests approximately one year before the launch of the HST. These tests are operated and reported on by the MSFC, but are managed and funded by Goddard Space Flight Center in direct support of the HST program. The HST Ni-H2 batteries are built from Eagle Picher RNH-90-3 cells. The HST EPS (electrical power system) is a direct energy transfer power system. The HST Ni-H2 Six Battery Test is a breadboard of the HST EPS. The batteries in the test are composed of test module cells and packaged into three battery modules identical to the flight modules. This test is the HST EPS testbed. The 'Flight Spare Battery' Test is a simulation of one of the six battery channels on the HST. The cells in the test are from the flight spare lot of cells, which are the same lot of cells that three of the six HST flight batteries are made from. This test is the battery life test for the HST program.
1970-03-01
The Apollo Telescope Mount (ATM) was designed and developed by the Marshall Space Flight Center (MSFC) and served as the primary scientific instrument unit aboard Skylab (1973-1979). The ATM consisted of eight scientific instruments as well as a number of smaller experiments. This image is of the ATM thermal unit being tested in MSFC's building 4619. The thermal unit consisted of an active fluid-cooling system of water and methanol that was circulated to radiators on the outside of the canister. The thermal unit provided temperature stability to the ultrahigh resolution optical instruments that were part of the ATM.
The MSFC UNIVAC 1108 EXEC 8 simulation model
NASA Technical Reports Server (NTRS)
Williams, T. G.; Richards, F. M.; Weatherbee, J. E.; Paul, L. K.
1972-01-01
A model is presented which simulates the MSFC Univac 1108 multiprocessor system. The hardware/operating system is described to enable a good statistical measurement of the system behavior. The performance of the 1108 is evaluated by performing twenty-four different experiments designed to locate system bottlenecks and also to test the sensitivity of system throughput with respect to perturbation of the various Exec 8 scheduling algorithms. The model is implemented in the general purpose system simulation language and the techniques described can be used to assist in the design, development, and evaluation of multiprocessor systems.
NASA Technical Reports Server (NTRS)
Justus, C. G.; Alyea, F. N.; Cunnold, D. M.; Jeffries, W. R., III; Johnson, D. L.
1991-01-01
A new (1990) version of the NASA/MSFC Global Reference Atmospheric Model (GRAM-90) was completed and the program and key data base listing are presented. GRAM-90 incorporate extensive new data, mostly collected under the Middle Atmosphere Program, to produce a completely revised middle atmosphere model (20 to 120 km). At altitudes greater than 120 km, GRAM-90 uses the NASA Marshall Engineering Thermosphere model. Complete listings of all program and major data bases are presented. Also, a test case is included.
2002-10-11
KENNEDY SPACE CENTER, FLA. -- This 100-pound Mundrabilla meteorite sample is being studied in Wyle Laboratory's Nondestructive Testing Laboratory at KSC. The one-of-a-kind meteorite was found 36 years ago in Australia and is on loan to Marshall Space Flight Center (MSFC) from the Smithsonian Institution's National Museum of Natural History. Dr. Donald Gillies, discipline scientist for materials science at MSFC's Microgravity Science and Applications Department, is the Principal Investigator. The studies may help provide the science community and industry with fundamental knowledge for use in the design of advanced materials.
2002-10-11
KENNEDY SPACE CENTER, FLA. -- This 100-pound Mundrabilla meteorite sample is being studied in Wyle Laboratory's Nondestructive Testing Laboratory at KSC. The one-of-a-kind meteorite was found 36 years ago in Australia and is on loan to Marshall Space Flight Center (MSFC) from the Smithsonian Institution's National Museum of Natural History. Dr. Donald Gillies, discipline scientist for materials science at MSFC's Microgravity Science and Applications Department, is the Principal Investigator. The studies may help provide the science community and industry with fundamental knowledge for use in the design of advanced materials.
1967-11-01
Workmen at the Kennedy Space Center hoist the Saturn Lunar Module (LM) Adapter into position during assembly of the 204LM-1, an unmanned Apollo mission that tested the Apollo Lunar Module in Earth orbit. Also known as Apollo 5, the spacecraft was launched on the fourth Saturn IB launch vehicle. Developed by the Marshall Space Flight Center (MSFC) as an interim vehicle in MSFC's "building block" approach to the Saturn rocket development, the Saturn IB utilized Saturn I technology to further develop and refine a larger booster and the Apollo spacecraft capabilities required for the manned lunar missions.
Eclipse 2017: Partnering with NASA MSFC to Inspire Students
NASA Technical Reports Server (NTRS)
Fry, Craig " Ghee"
2017-01-01
NASA's Marshall Space Flight Center (MSFC) is partnering with the U.S. Space and Rocket Center (USSRC), and Austin Peay State University (APSU) to engage citizen scientists, engineers, and students in science investigations during the 2017 American Solar Eclipse. Investigations will support the Citizen Continental America Telescopic Eclipse (CATE), Ham Radio Science Citizen Investigation(HamSCI), and Interactive NASA Space Physics Ionosphere Radio Experiments (INSPIRE). All planned activities will engage Space Campers and local high school students in the application of the scientific method as they seek to explore a wide range of observations during the eclipse. Where planned experiments touch on current scientific questions, the camper/students will be acting as citizen scientists, participating with researchers from APSU and MSFC. Participants will test their expectations and after the eclipse, share their results, experiences, and conclusions to younger Space Campers at the US Space & Rocket Center.
Intelligent Vision Systems Independent Research and Development (IR&D) 2006
NASA Technical Reports Server (NTRS)
Patrick, Clinton; Chavis, Katherine
2006-01-01
This report summarizes results in conduct of research sponsored by the 2006 Independent Research and Development (IR&D) program at Marshall Space Flight Center (MSFC) at Redstone Arsenal, Alabama. The focus of this IR&D is neural network (NN) technology provided by Imagination Engines, Incorporated (IEI) of St. Louis, Missouri. The technology already has many commercial, military, and governmental applications, and a rapidly growing list of other potential spin-offs. The goal for this IR&D is implementation and demonstration of the technology for autonomous robotic operations, first in software and ultimately in one or more hardware realizations. Testing is targeted specifically to the MSFC Flat Floor, but may also include other robotic platforms at MSFC, as time and funds permit. For the purpose of this report, the NN technology will be referred to by IEI's designation for a subset configuration of its patented technology suite: Self-Training Autonomous Neural Network Object (STANNO).
Space Environmental Effects on Coated Tether Materials
NASA Technical Reports Server (NTRS)
Gittemeier, Keith A.; Hawk, Clark W.; Finckenor, Miria M.; Watts, Ed
2005-01-01
The University of Alabama in Huntsville s Propulsion Research Center has teamed with NASA's Marshall Space Flight Center (MSFC) to research the effects of atomic oxygen (AO) bombardment on coated tether materials. Tethers Unlimited Inc. has provided several candidate tether materials with various coatings for AO exposure in MSFC s Atomic Oxygen Beam Facility. Additional samples were exposed to ultraviolet (UV) radiation at MSFC. AO erodes most organic materials, and ultraviolet radiation embrittles polymers. This test series was performed to determine the effect of AO and UV on the mechanical integrity of tether materials that were treated with AO-protective coatings, such as polyhedral oligomeric silsesquioxane (POSS) or metallization. Both TUI's Multi-Application Survivable Tether (MAST) Experiment and Marshall Space Flight Center s Momentum Exchange Electrodynamic Reboost (MXER) programs will benefit from this research by helping to determine tether materials and coatings that give the longest life with the lowest mass penalty.
NASA Technical Reports Server (NTRS)
Ramsey, P. E.
1976-01-01
An aerodynamic investigation was conducted in the MSFC High Reynolds Number Wind Tunnel to determine the pressure distribution over the foresection of the current 146 inch diameter shuttle SRB. The test model consisted of a 0.0137 scale version of the SRB nose cone and a forward portion of the cylindrical body which was approximately 2.7 calibers in length. The pressure distributions are plotted as a function of longitudinal station ratioed to body diameter and circumferential location for each angle of attack and Mach number. A Reynolds number variation study was made for Mach numbers of 0.4 and 0.6 at an angle of attack of 270 deg and roll angle of 180 deg.
Atomic Oxygen Effects on Coated Tether Materials
NASA Technical Reports Server (NTRS)
Gittemeier, Keith A.; Hawk, Clark W.; Finckenor, Miria M.; Watts, Ed
2005-01-01
The University of Alabama in Huntsville s Propulsion Research Center has teamed with NASA's Marshall Space Flight Center (MSFC) to research the effects of atomic oxygen (AO) bombardment on coated tether materials. Tethers Unlimited Inc. has provided several candidate tether materials with various coatings for (AO) exposure in MSFC's Atomic Oxygen Beam Facility. Additional samples were exposed to ultraviolet (UV) radiation at MSFC. AO erodes most organic materials, and ultraviolet radiation embrittles polymers. This test series was performed to determine the effect of AO and UV on the mechanical integrity of tether materials that were treated with AO-protective coatings, such as Photosil or metallization. Both TUI's Multi-Application Survivable Tether (MAST) Experiment and Marshall Space Flight Center's Momentum Exchange Electrodynamic Reboost (MXER) programs will benefit from this research by helping to determine tether materials and coatings that give the longest life with the lowest mass penalty.
International Space Station (ISS)
2001-02-01
The Marshall Space Flight Center (MSFC) is responsible for designing and building the life support systems that will provide the crew of the International Space Station (ISS) a comfortable environment in which to live and work. Scientists and engineers at the MSFC are working together to provide the ISS with systems that are safe, efficient, and cost-effective. These compact and powerful systems are collectively called the Environmental Control and Life Support Systems, or simply, ECLSS. This is a view of the ECLSS and the Internal Thermal Control System (ITCS) Test Facility in building 4755, MSFC. In the foreground is the 3-module ECLSS simulator comprised of the U.S. Laboratory Module Simulator, Node 1 Simulator, and Node 3/Habitation Module Simulator. At center left is the ITCS Simulator. The main function of the ITCS is to control the temperature of equipment and hardware installed in a typical ISS Payload Rack.
International Space Station (ISS)
2001-02-01
The Marshall Space Flight Center (MSFC) is responsible for designing and building the life support systems that will provide the crew of the International Space Station (ISS) a comfortable environment in which to live and work. Scientists and engineers at the MSFC are working together to provide the ISS with systems that are safe, efficient, and cost-effective. These compact and powerful systems are collectively called the Environmental Control and Life Support Systems, or simply, ECLSS. This is a view of the ECLSS and the Internal Thermal Control System (ITCS) Test Facility in building 4755, MSFC. In the foreground is the 3-module ECLSS simulator comprised of the U.S. Laboratory Module Simulator, Node 1 Simulator, and Node 3/Habitation Module Simulator. On the left is the ITCS Simulator. The main function of the ITCS is to control the temperature of equipment and hardware installed in a typical ISS Payload Rack.
1980-09-23
Pictured is a dual position Saturn I/IB test at the T-Stand at Marshall Space Flight Center. This stand was built to test two articles at the same time, thus providing engineers at MSFC with the opportunity to compare identical burns.
Repeatability and uncertainty analyses of light gas gun test data
NASA Technical Reports Server (NTRS)
Schonberg, William P.; Cooper, David
1994-01-01
All large spacecraft are susceptible to high-speed impacts by meteoroids and pieces of orbiting space debris which can damage flight-critical systems and in turn lead to catastrophic failure. One way to obtain information on the response of a structure to a meteoroid impact or an orbital debris impact is to simulate the impact conditions of interest in the laboratory and analyze the resulting damage to a target structure. As part of the Phase B and C/D development activities for the Space Station Freedom, 950 impact tests were performed using the NASA/Marshall Space Flight Center (MSFC) light gas gun from 1985-1991. This paper presents the results of impact phenomena repeatability and data uncertainty studies performed using the information obtained from those tests. The results of these studies can be used to assess the utility of individual current and future NASA/MSFC impact test results in the design of long-duration spacecraft.
Thin-film sensors for space propulsion technology: Fabrication and preparation for testing
NASA Technical Reports Server (NTRS)
Kim, Walter S.; Hepp, Aloysius F.
1989-01-01
The goal of this work is to develop and test thin-film thermocouples for Space Shuttle Main Engine (SSME) components. Thin-film thermocouples have been developed for aircraft gas turbine engines and are in use for temperature measurement on turbine blades up to 1800 F. Established aircraft engine gas turbine technology is currently being adapted to turbine engine blade materials and the environment encountered in the SSME, especially severe thermal shock from cryogenic fuel to combustion temperatures. Initial results using coupons of MAR M-246 (+Hf) and PWA 1480 have been followed by fabrication of thin-film thermocouples on SSME turbine blades. Current efforts are focused on preparing for testing in the Turbine Blade Tester at the NASA Marshall Space Flight Center (MSFC). Future work will include testing of thin-film thermocouples on SSME blades of single crystal PWA 1480 at MSFC.
Experimental Performance Evaluation of a Supersonic Turbine for Rocket Engine Applications
NASA Technical Reports Server (NTRS)
Snellgrove, Lauren M.; Griffin, Lisa W.; Sieja, James P.; Huber, Frank W.
2003-01-01
In order to mitigate the risk of rocket propulsion development, efficient, accurate, detailed fluid dynamics analysis and testing of the turbomachinery is necessary. To support this requirement, a task was developed at NASA Marshall Space Flight Center (MSFC) to improve turbine aerodynamic performance through the application of advanced design and analysis tools. These tools were applied to optimize a supersonic turbine design suitable for a reusable launch vehicle (RLV). The hot gas path and blading were redesigned-to obtain an increased efficiency. The goal of the demonstration was to increase the total-to- static efficiency of the turbine by eight points over the baseline design. A sub-scale, cold flow test article modeling the final optimized turbine was designed, manufactured, and tested in air at MSFC s Turbine Airflow Facility. Extensive on- and off- design point performance data, steady-state data, and unsteady blade loading data were collected during testing.
Design and analysis of seals for extended service life
NASA Technical Reports Server (NTRS)
Bower, Mark V.
1992-01-01
Space Station Freedom is being developed for a service life of up to thirty years. As a consequence, the design requirements for the seals to be used are unprecedented. Full scale testing to assure the selected seals can satisfy the design requirements are not feasible. As an alternative, a sub-scale test program has been developed by MSFC to calibrate the analysis tools to be used to certify the proposed design. This research has been conducted in support of the MSFC Integrated Seal Test Program. The ultimate objective of this research is to correlate analysis and test results to qualify the analytical tools, which in turn, are to be used to qualify the flight hardware. This research is totally focused on O-rings that are compressed by perpendicular clamping forces. In this type of seal the O-ring is clamped between the sealing surfaces by loads perpendicular to the circular cross section.
NASA GRC and MSFC Space-Plasma Arc Testing Procedures
NASA Technical Reports Server (NTRS)
Ferguson, Dale C.; Vayner, Boris V.; Galofaro, Joel T,; Hillard, G. Barry; Vaughn, Jason; Schneider, Todd
2005-01-01
Tests of arcing and current collection in simulated space plasma conditions have been performed at the NASA Glenn Research Center (GRC) in Cleveland, Ohio, for over 30 years and at the Marshall Space Flight Center (MSFC) in Huntsville, Alabama, for almost as long. During this period, proper test conditions for accurate and meaningful space simulation have been worked out, comparisons with actual space performance in spaceflight tests and with real operational satellites have been made, and NASA has achieved our own internal standards for test protocols. It is the purpose of this paper to communicate the test conditions, test procedures, and types of analysis used at NASA GRC and MSFC to the space environmental testing community at large, to help with international space-plasma arcing-testing standardization. To be discussed are: 1.Neutral pressures, neutral gases, and vacuum chamber sizes. 2. Electron and ion densities, plasma uniformity, sample sizes, and Debuy lengths. 3. Biasing samples versus self-generated voltages. Floating samples versus grounded. 4. Power supplies and current limits. Isolation of samples from power supplies during arcs. 5. Arc circuits. Capacitance during biased arc-threshold tests. Capacitance during sustained arcing and damage tests. Arc detection. Prevention sustained discharges during testing. 6. Real array or structure samples versus idealized samples. 7. Validity of LEO tests for GEO samples. 8. Extracting arc threshold information from arc rate versus voltage tests. 9. Snapover and current collection at positive sample bias. Glows at positive bias. Kapon (R) pyrolisis. 10. Trigger arc thresholds. Sustained arc thresholds. Paschen discharge during sustained arcing. 11. Testing for Paschen discharge threshold. Testing for dielectric breakdown thresholds. Testing for tether arcing. 12. Testing in very dense plasmas (ie thruster plumes). 13. Arc mitigation strategies. Charging mitigation strategies. Models. 14. Analysis of test results. Finally, the necessity of testing will be emphasized, not to the exclusion of modeling, but as part of a complete strategy for determining when and if arcs will occur, and preventing them from occurring in space.
NASA GRC and MSFC Space-Plasma Arc Testing Procedures
NASA Technical Reports Server (NTRS)
Ferguson, Dale C.a; Vayner, Boris V.; Galofaro, Joel T.; Hillard, G. Barry; Vaughn, Jason; Schneider, Todd
2005-01-01
Tests of arcing and current collection in simulated space plasma conditions have been performed at the NASA Glenn Research Center (GRC) in Cleveland, Ohio, for over 30 years and at the Marshall Space flight Center (MSFC) for almost as long. During this period, proper test conditions for accurate and meaningful space simulation have been worked out, comparisons with actual space performance in spaceflight tests and with real operational satellites have been made, and NASA has achieved our own internal standards for test protocols. It is the purpose of this paper to communicate the test conditions, test procedures, and types of analysis used at NASA GRC and MSFC to the space environmental testing community at large, to help with international space-plasma arcing testing standardization. To be discussed are: 1. Neutral pressures, neutral gases, and vacuum chamber sizes. 2. Electron and ion densities, plasma uniformity, sample sizes, and Debye lengths. 3. Biasing samples versus self-generated voltages. Floating samples versus grounded. 4. Power supplies and current limits. Isolation of samples from power supplies during arcs. Arc circuits. Capacitance during biased arc-threshold tests. Capacitance during sustained arcing and damage tests. Arc detection. Preventing sustained discharges during testing. 5. Real array or structure samples versus idealized samples. 6. Validity of LEO tests for GEO samples. 7. Extracting arc threshold information from arc rate versus voltage tests. 8 . Snapover and current collection at positive sample bias. Glows at positive bias. Kapton pyrolization. 9. Trigger arc thresholds. Sustained arc thresholds. Paschen discharge during sustained arcing. 10. Testing for Paschen discharge thresholds. Testing for dielectric breakdown thresholds. Testing for tether arcing. 11. Testing in very dense plasmas (ie thruster plumes). 12. Arc mitigation strategies. Charging mitigation strategies. Models. 13. Analysis of test results. Finally, the necessity of testing will be emphasized, not to the exclusion of modeling, but as part of a complete strategy for determining when and if arcs will occur, and preventing them from occurring in space.
1966-06-21
Dr. Joseph Randall, a laser expert at Marshall Space Flight Center (MSFC), explains one of the projects he is working on to a group composed of Federal Republic of Germany and MSFC officials. From left are: Dr. Randall; Minister for Scientific Research of Federal Republic of Germany, Dr. Gerhard Stolenberg; Director of MSFC Astrionics Lab, Dr. Walter Haeusserman; Head of Space Research Federal Republic of Germany, Max Mayer; MSFC Director Dr. von Braun; MSFC Deputy Director Dr. Elberhard Rees.
Wolle, Meraf A; DeMill, David L; Johnson, Lauren; Lentz, Stephen I; Woodward, Maria A; Mian, Shahzad I
2017-11-01
Availability of preloaded Descemet membrane endothelial keratoplasty (pDMEK) tissue may increase acceptance of DMEK in surgical management of endothelial disease. The goal of this study was to determine the safety of pDMEK grafts for 24 hours before surgery by analyzing endothelial cell loss (ECL) using 2 image analysis software programs. A total of 18 cadaveric corneas were prepared for DMEK using a standardized technique and loaded in a modified Jones tube injector. Nine of the corneas were injected into Calcein AM vital dye after 1 minute (controls), and the remaining 9 corneas were left preloaded for 24 hours before injection into vital dye for staining. The stained corneas were imaged using an inverted confocal microscope. ECL was then analyzed and quantified by 2 different graders using 2 image analysis software programs. The control DMEK tissue resulted in 22.0% ± 4.0% ECL compared with pDMEK tissue, which resulted in 19.2% ± 7.2% ECL (P = 0.31). Interobserver agreement was 0.93 for MetaMorph and 0.92 for Fiji. The average time required to process images with MetaMorph was 2 ± 1 minutes and with Fiji was 20 ± 10 minutes. Intraobserver agreement was 0.97 for MetaMorph and 0.93 for Fiji. Preloading DMEK tissue is safe and may provide an alternative technique for tissue distribution and surgery for DMEK. The use of MetaMorph software for quantifying ECL is a novel and accurate imaging method with increased efficiency and reproducibility compared with the previously validated Fiji.
Thobunluepop, Pitipong
2009-08-15
Presently, chemical seed treatments are in discussion due to their directly or indirectly impacts on human health or other living organisms. They may also negatively affect the ecosystem and the food chain. In rice seeds, chemicals may cause phytotoxic effects including seed degradation. Eugenol is the main component of clove (Eugenia caryophillis) oil, which was proved to act simultaneously as bactericide, virocide and especially fungicide. The in vitro study was aimed to compare the inhibitory effect of the following seed treatment substances against seed borne fungi and their shelf-life during 12 months of storage; conventional captan (CA), chitosan-lignosulphonate polymer (CL), eugenol incorporated into chitosan-lignosulphonate polymer (E+CL) and control (CO). The obtained results of fungi inhibition were classified in three groups, which showed at first that CA treatment led to a better, i.e., longer, inhibitory effect on Alternaria padwickii, Rhizoctonia solani, Curvularia sp., Aspergillus flavus and Aspergillus niger than E+CL. Secondly, E+CL coating polymer showed the longest inhibitory effect against Bipolaris oryzae and Nigrospora oryzae compared to CA and CL coating polymer. Finally, both CA and E+CL coating polymer had non-significant difference inhibitory effect on Fusarium moniliforme. The variant of CL coating polymer for seed coating was only during the first 6 months of storage able to inhibit all species of the observed seed borne fungi, whereas CA and E+CL coating polymer were capable to inhibit most of the fungi until 9 months of storage.
Yuan, Yali; Wei, Shiqiang; Liu, Guangpeng; Xie, Shunbi; Chai, Yaqin; Yuan, Ruo
2014-02-06
In this study, we for the first time presented an efficient, accurate, rapid, simple and ultrasensitive detection system for small molecule ochratoxin A (OTA) by using the integration of loop-mediated isothermal amplification (LAMP) technique and subsequently direct readout of LAMP amplicons with a signal-on electrochemiluminescent (ECL) system. Firstly, the dsDNA composed by OTA aptamer and its capture DNA were immobilized on the electrode. After the target recognition, the OTA aptamer bond with target OTA and subsequently left off the electrode, which effectively decreased the immobilization amount of OTA aptamer on electrode. Then, the remaining OTA aptamers on the electrode served as inner primer to initiate the LAMP reaction. Interestingly, the LAMP amplification was detected by monitoring the intercalation of DNA-binding Ru(phen)3(2+) ECL indictors into newly formed amplicons with a set of integrated electrodes. The ECL indictor Ru(phen)3(2+) binding to amplicons caused the reduction of the ECL intensity due to the slow diffusion of Ru(phen)3(2+)-amplicons complex to the electrode surface. Therefore, the presence of more OTA was expected to lead to the release of more OTA aptamer, which meant less OTA aptamer remained on electrode for producing LAMP amplicons, resulting in less Ru(phen)3(2+) interlaced into the formed amplicons within a fixed Ru(phen)3(2+) amount with an obviously increased ECL signal input. As a result, a detection limit as low as 10 fM for OTA was achieved. The aptasensor also has good reproducibility and stability. Copyright © 2013 Elsevier B.V. All rights reserved.
Mégarbane, Bruno; Leprince, Pascal; Deye, Nicolas; Résière, Dabor; Guerrier, Gilles; Rettab, Samia; Théodore, Jonathan; Karyo, Souheil; Gandjbakhch, Iradj; Baud, Frédéric J
2007-05-01
To report the feasibility, complications, and outcomes of emergency extracorporeal life support (ECLS) in refractory cardiac arrests in medical intensive care unit (ICU). Prospective cohort study in the medical ICU in a university hospital in collaboration with the cardiosurgical team of a neighboring hospital. Seventeen patients (poisonings: 12/17) admitted over a 2-year period for cardiac arrest unresponsive to cardiopulmonary resuscitation (CPR) and advanced cardiac life support, without return of spontaneous circulation. ECLS femoral implantation under continuous cardiac massage, using a centrifugal pump connected to a hollow-fiber membrane oxygenator. Stable ECLS was achieved in 14 of 17 patients. Early complications included massive transfusions (n=8) and the need for surgical revision at the cannulation site for bleeding (n=1). Four patients (24%) survived at medical ICU discharge. Deaths resulted from multiorgan failure (n=8), thoracic bleeding(n=2), severe sepsis (n=2), and brain death (n=1). Massive hemorrhagic pulmonary edema during CPR (n=5) and major capillary leak syndrome (n=6) were observed. Three cardiotoxic-poisoned patients (18%, CPR duration: 30, 100, and 180 min) were alive at 1-year follow-up without sequelae. Two of these patients survived despite elevated plasma lactate concentrations before cannulation (39.0 and 20.0 mmol/l). ECLS was associated with a significantly lower ICU mortality rate than that expected from the Simplified Acute Physiology Score II (91.9%) and lower than the maximum Sequential Organ Failure Assessment score (>90%). Emergency ECLS is feasible in medical ICU and should be considered as a resuscitative tool for selected patients suffering from refractory cardiac arrest.
Overview af MSFC's Applied Fluid Dynamics Analysis Group Activities
NASA Technical Reports Server (NTRS)
Garcia, Roberto; Griffin, Lisa; Williams, Robert
2004-01-01
This paper presents viewgraphs on NASA Marshall Space Flight Center's Applied Fluid Dynamics Analysis Group Activities. The topics include: 1) Status of programs at MSFC; 2) Fluid Mechanics at MSFC; 3) Relevant Fluid Dynamics Activities at MSFC; and 4) Shuttle Return to Flight.
Members of House Committee on Science and Astronautics Visited MSFC
NASA Technical Reports Server (NTRS)
1962-01-01
The members of the House Committee on Science and Astronautics visited the Marshall Space Flight Center (MSFC) on March 9, 1962 to gather firsthand information of the nation's space exploration program. The congressional group was composed of members of the Subcommittee on Manned Space Flight. The subcommittee was briefed on MSFC's manned space efforts earlier in the day and then inspected mockups of the Saturn I Workshop and the Apollo Telescope Mount, two projects developed by MSFC for the post-Apollo program. In this photograph, MSFC Director, Dr. Wernher von Braun meets with Congressmen in the MSFC boardroom. Pictured from left to right are: Jack Cramer, NASA Headquarters; Joe Waggoner, Democratic representative of Louisiana; John W. Davis, Democratic representative of Georgia; R. Walter Riehlman, Republican representative of New York; Olin E. Teague, Democratic representative of Texas; Dr. Wernher von Braun, Director of MSFC; James G. Fulton, Republican representative of Pennsylvania; Ken Hechler, Democratic representative of West Virginia; and Erich Neubert of MSFC.
Life testing of secondary silver-zinc cells for the orbiting maneuvering vehicle
NASA Technical Reports Server (NTRS)
Brewer, Jeffrey C.; Doreswamy, Rajiv; Jackson, Lorna G.
1990-01-01
Over the past 5 years, extensive testing has been performed at the Marshall Space Flight Center (MSFC) on a variety of secondary (rechargeable) silver-zinc (Ag-Zn) cells for the Orbital Maneuvering Vehicle (OMV). The first tests performed were to determine the feasibility of using such a cell in a long-life (18-month), low-Earth-orbit (LEO) application. Results from these tests were promising, so testing continued with a 250-Ah cell that was specifically designed for this type of application. Once again, results from the tests were promising. Following a review of the data from these previous tests, slight modifications to the 250-Ah design were necessary to alleviate problem areas. Currently, MSFC is testing a 350-Ah design that has incorporated these changes and is the baseline design for the OMV. This test began in mid-November, 1989, and will be complete in the spring of 1991, barring any substantial offline time. A report is presented on the preliminary results from the first few months of this test and they are compared to results obtained in previous tests done at MFSC.
ERIC Educational Resources Information Center
Meece, Darrell
2013-01-01
The current investigation examined continuity from 9-months to 4-years of age in father-child interaction in instrumental child care activities, as well as enrichment and play activities, using data collected from 8,450 children with residential fathers included in the Early Childhood Longitudinal Study, Birth Cohort (ECLS-B). Additionally, social…
ERIC Educational Resources Information Center
Wilson, Hope E.
2015-01-01
Research has demonstrated mixed results regarding differences in social and emotional characteristics between gifted and typical populations. The purpose of this secondary analysis of data from the Early Childhood Longitudinal Study: Birth Cohort (ECLS-B) is to investigate the affective characteristics of early mathematics and literacy ability…
Wang, Sui; Hao, Tingting; Yu, Xinwei; Gai, Panpan; Guo, Zhiyong
2012-04-01
Gentian violet (GV) was found to quench the electrochemiluminescence (ECL) of the tris(2,2'-bipyridyl)ruthenium(II)/tris-n-propylamine (Ru(bpy)3(2+)-TPA) system at a glass carbon electrode (GCE). Based on the ECL signal changes, a simple and ultrasensitive detection method for GV in aquatic water was established. Under the optimized conditions, the quenched ECL intensity versus the logarithm of the concentration of GV was linear over a concentration range from 1.0×10(-10) to 5.0×10(-7) mol L(-1), and the limit of detection (LOD) was found to be 4.5×10(-12) mol L(-1) (S/N=3). The results obtained by the ECL system were better than other reported methods in literatures in terms of sensitivity or linear response range. The method was successfully applied to determine GV in aquatic water, and the relative standard deviations (RSDs) were found less than 6.3%, and the recoveries were obtained from 98.7 to 111.0%. Moreover, a possible mechanism of the quenching effect was primarily discussed based on UV-visible absorption spectra, cyclic voltammograms and IECL-E curves. Copyright © 2011 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Lowrey, Nikki M.; Mitchell, Mark A.
2016-01-01
Since the 1990's, when the Class I Ozone Depleting Substance (ODS) chlorofluorocarbon-113 (CFC-113) was banned, NASA's propulsion test facilities at Marshall Space Flight Center (MSFC) and Stennis Space Center (SSC) have relied upon the solvent AsahiKlin AK-225 (hydrochlorofluorocarbon-225ca/cb or HCFC-225ca/cb) and, more recently AK-225G (the single isomer form, HCFC-225cb) to safely clean and verify the cleanliness of large scale propulsion oxygen systems. Effective January 1, 2015, the production, import, export, and new use of Class II Ozone Depleting Substances, including AK-225G, was prohibited in the United States by the Clean Air Act. In 2012 through 2014, NASA test labs at MSFC, SSC, and Johnson Space Center's White Sands Test Facility (WSTF) collaborated to seek out, test, and qualify a solvent replacement for AK-225G that is both an effective cleaner and safe for use with oxygen systems. This paper summarizes the tests performed, results, and lessons learned.
Holographic flow diagnostics for the Space Shuttle main engine
NASA Technical Reports Server (NTRS)
1992-01-01
Summarized here are the results of an effort to produce holograms of the exhaust from the Space Shuttle Main Engine (SSME) being tested on a test stand at the Marshall Space Flight Center (MSFC). The effort took place from December 1990 to January 1992, during which seven trips were made from MetroLaser to MSFC. A brief outline of each trip is given. Due to the suspension of the SSME program in Huntsville and unexpected complications in resolving safety issues, the proposed holography system was not operated until November 1991. A NASA 100 mW Argon laser was installed in the holography system for an October engine test while these safety issues were being resolved. A video camera shadowgraph was made during this test, which was shut down prematurely after 20 seconds. System problems precluded successful operation of the holography system until the January 1992 engine test. No hologram resulted during this test due to heavy fog conditions around the engine.
1962-03-08
The members of the House Committee on Science and Astronautics visited the Marshall Space Flight Center (MSFC) on March 9, 1962 to gather firsthand information of the nation's space exploration program. The congressional group was composed of members of the Subcommittee on Manned Space Flight. They were briefed on MSFC's manned space efforts earlier in the day and then inspected mockups of the Saturn I Workshop and the Apollo Telescope Mount, two projects developed by MSFC for the post-Apollo program. Pictured left-to-right are Dieter Grau, MSFC; Konrad Dannenberg, MSFC; James G. Fulton, Republican representative for Pennsylvania; Joe Waggoner, Democratic representative for Louisiana; and Dr. Wernher von Braun, Director of MSFC.
Assessment issues in the testing of children at school entry.
Rock, Donald A; Stenner, A Jackson
2005-01-01
The authors introduce readers to the research documenting racial and ethnic gaps in school readiness. They describe the key tests, including the Peabody Picture Vocabulary Test (PPVT), the Early Childhood Longitudinal Study (ECLS), and several intelligence tests, and describe how they have been administered to several important national samples of children. Next, the authors review the different estimates of the gaps and discuss how to interpret these differences. In interpreting test results, researchers use the statistical term "standard deviation" to compare scores across the tests. On average, the tests find a gap of about 1 standard deviation. The ECLS-K estimate is the lowest, about half a standard deviation. The PPVT estimate is the highest, sometimes more than 1 standard deviation. When researchers adjust those gaps statistically to take into account different outside factors that might affect children's test scores, such as family income or home environment, the gap narrows but does not disappear. Why such different estimates of the gap? The authors consider explanations such as differences in the samples, racial or ethnic bias in the tests, and whether the tests reflect different aspects of school "readiness," and conclude that none is likely to explain the varying estimates. Another possible explanation is the Spearman Hypothesis-that all tests are imperfect measures of a general ability construct, g; the more highly a given test correlates with g, the larger the gap will be. But the Spearman Hypothesis, too, leaves questions to be investigated. A gap of 1 standard deviation may not seem large, but the authors show clearly how it results in striking disparities in the performance of black and white students and why it should be of serious concern to policymakers.
NASA Technical Reports Server (NTRS)
Knox, James C.; Mulloth, Lila M.; Affleck, David L.
2004-01-01
Accumulation and subsequent compression of carbon dioxide that is removed from space cabin are two important processes involved in a closed-loop air revitalization scheme of the International Space Station (ISS). The 4-Bed Molecular Sieve (4BMS) of ISS currently operates in an open loop mode without a compressor. This paper reports the integrated 4BMS and liquid-cooled TSAC testing conducted during the period of March 3 to April 18, 2003. The TSAC prototype was developed at NASA Ames Research Center (ARC). The 4BMS was modified to a functionally flight-like condition at NASA Marshall Space Flight Center (MSFC). Testing was conducted at MSFC. The paper provides details of the TSAC operation at various CO2 loadings and corresponding performance of CDRA.
2011-03-24
CHARLES BOLDEN, NASA ADMINISTRATOR PRESENTING THE 2010 ADMINISTRATOR’S CUP AWARD TO DAVID BROCK, SMALL BUSINESS SPECIALIST, MSFC. LEFT TO RIGHT GLENN DELGADO, ASSOCIATE DIRECTOR, NASA, OFFICE OF SMALL BUSINESS PROGRAMS, BYRON BUTLER, DIRECTOR, OFFICE OF PROCUREMENT, MSFC, DAVID BROCK, SMALL BUSINESS SPECIALIST, MSFC, CHARLES BOLDEN, NASA ADMINISTRATOR AND ROBERT LIGHTFOOT, MSFC CENTER DIRECTOR.
NASA Astrophysics Data System (ADS)
Dong, Yongqiang; Dai, Ruiping; Dong, Tongqing; Chi, Yuwu; Chen, Guonan
2014-09-01
Single-layer graphene quantum dots (SGQDs) were refluxed with hydrazine (N2H4) to prepare hydrazide-modified SGQDs (HM-SGQDs). Compared with SGQDs, partial oxygen-containing groups have been removed from HM-SGQDs. At the same time, a lot of hydrazide groups have been introduced into HM-SGQDs. The introduced hydrazide groups provide HM-SGQDs with a new kind of surface state, and give HM-SGQDs unique photoluminescence (PL) properties such as blue-shifted PL emission and a relatively high PL quantum yield. More importantly, the hydrazide-modification made HM-SGQDs have abundant luminol-like units. Accordingly, HM-SGQDs exhibit unique and excellent chemiluminescence (CL) and anodic electrochemiluminescence (ECL). The hydrazide groups of HM-SGQDs can be chemically oxidized by the dissolved oxygen (O2) in alkaline solutions, producing a strong CL signal. The CL intensity is mainly dependent on the pH value and the concentration of O2, implying the potential applications of HM-SGQDs in pH and O2 sensors. The hydrazide groups of HM-SGQDs can also be electrochemically oxidized in alkaline solutions, producing a strong anodic ECL signal. The ECL intensity can be enhanced sensitively by hydrogen peroxide (H2O2). The enhanced ECL intensity is proportional to the concentration of H2O2 in a wide range of 3 μM to 500 μM. The detection limit of H2O2 was calculated to be about 0.7 μM. The results suggest the great potential applications of HM-SGQDs in the sensors of H2O2 and bio-molecules that are able to produce H2O2 in the presence of enzymes.Single-layer graphene quantum dots (SGQDs) were refluxed with hydrazine (N2H4) to prepare hydrazide-modified SGQDs (HM-SGQDs). Compared with SGQDs, partial oxygen-containing groups have been removed from HM-SGQDs. At the same time, a lot of hydrazide groups have been introduced into HM-SGQDs. The introduced hydrazide groups provide HM-SGQDs with a new kind of surface state, and give HM-SGQDs unique photoluminescence (PL) properties such as blue-shifted PL emission and a relatively high PL quantum yield. More importantly, the hydrazide-modification made HM-SGQDs have abundant luminol-like units. Accordingly, HM-SGQDs exhibit unique and excellent chemiluminescence (CL) and anodic electrochemiluminescence (ECL). The hydrazide groups of HM-SGQDs can be chemically oxidized by the dissolved oxygen (O2) in alkaline solutions, producing a strong CL signal. The CL intensity is mainly dependent on the pH value and the concentration of O2, implying the potential applications of HM-SGQDs in pH and O2 sensors. The hydrazide groups of HM-SGQDs can also be electrochemically oxidized in alkaline solutions, producing a strong anodic ECL signal. The ECL intensity can be enhanced sensitively by hydrogen peroxide (H2O2). The enhanced ECL intensity is proportional to the concentration of H2O2 in a wide range of 3 μM to 500 μM. The detection limit of H2O2 was calculated to be about 0.7 μM. The results suggest the great potential applications of HM-SGQDs in the sensors of H2O2 and bio-molecules that are able to produce H2O2 in the presence of enzymes. Electronic supplementary information (ESI) available: AFM images of SGQDs and HM-SGQDs (Fig. S1), FT-IR spectra of SGQDs and HM-SGQDs (Fig. S2), UV-vis and PL emission spectra of R-SGQDs (Fig. S3), cathodic ECL responses of SGQD, R-SGQDs and HM-SGQDs (Fig. S4), and the pH effect on the anodic ECL responses of HM-SGQDs (Fig. S5). See DOI: 10.1039/c4nr02539c
NASA. Marshall Space Flight Center Hydrostatic Bearing Activities
NASA Technical Reports Server (NTRS)
Benjamin, Theodore G.
1991-01-01
The basic approach for analyzing hydrostatic bearing flows at the Marshall Space Flight Center (MSFC) is briefly discussed. The Hydrostatic Bearing Team has responsibility for assessing and evaluating flow codes; evaluating friction, ignition, and galling effects; evaluating wear; and performing tests. The Office of Aerospace and Exploration Technology Turbomachinery Seals Tasks consist of tests and analysis. The MSFC in-house analyses utilize one-dimensional bulk-flow codes. Computational fluid dynamics (CFD) analysis is used to enhance understanding of bearing flow physics or to perform parametric analysis that are outside the bulk flow database. As long as the bulk flow codes are accurate enough for most needs, they will be utilized accordingly and will be supported by CFD analysis on an as-needed basis.
Kebede, Noah; Francis, Paul S; Barbante, Gregory J; Hogan, Conor F
2015-11-07
A series of aliphatic tertiary amines (HEPES, POPSO, EPPS and BIS-TRIS) commonly used to buffer the pH in biological experiments, were examined as alternative, non-toxic co-reactants for the electrogenerated chemiluminescence (ECL) of tris(2,2'-bipyridine)ruthenium(ii) ([Ru(bpy)3](2+)). These were found to be very attractive as "multi-tasking" reagents, serving not only as co-reactants, but also fulfiling the roles of pH buffer and supporting electrolyte within an aqueous environment; thus significantly simplifying the overall ECL analysis. Sub-nanomolar detection limits were obtained for [Ru(bpy)3](2+) in the presence of BIS-TRIS, making this species an valuable option for co-reactant ECL-based bioanalytical applications.
NASA Technical Reports Server (NTRS)
Williams, David E.
2004-01-01
The International Space Station (ISS) Environmental Control and Life Support (ECLS) system performance can be impacted by operations on ISS. This is especially important for the Temperature and Humidity Control (THC) and for the Fire Detection and Suppression (FDS) subsystems. It is also more important for Node 1 since it has become a convenient area for many crew tasks and for stowing hardware prior to Shuttle arrival. This paper will discuss the current requirements for ECLS keep out zones in Node 1; the issues with stowage in Node 1 during Increment 7 and how they impacted the keep out zone requirements; and the solution during Increment 7 and 8 for maintaining the keep out zones in Node 1.
Refractory Cardiogenic Shock During Tramadol Poisoning: A Case Report.
Belin, Nicolas; Clairet, Anne-Laure; Chocron, Sidney; Capellier, Gilles; Piton, Gaël
2017-04-01
Tramadol is a weak opioid analgesic indicated for the treatment of moderate to severe pain. Tramadol intoxication can be lethal, and this drug is frequently involved in voluntary overdose. Classically, tramadol intoxication is associated with neurological and respiratory side effects. In contrast, cardiac effects are poorly documented in the literature. We report a case of severe tramadol intoxication, with plasma concentration 20 times the toxic threshold, complicated by refractory cardiogenic shock, successfully treated by extra corporeal life support (ECLS) with a favorable cardiac outcome and ECLS weaning at day 10. Seizure, clonus, and nonreactive mydriasis were present during 4 days, and complete awakening was delayed to day 15. Poisoning caused by high doses of tramadol can lead to refractory cardiogenic shock, and ECLS can be considered as effective rescue therapy in this context.
THE HIGH INTENSITY SOLAR ENVIRONMENT TEST SYSTEM
2016-01-15
TODD SCHNEIDER LOOKS UP FROM WORK AT THE DOOR OF T HE HIGH INTENSITY SOLAR ENVIRONMENT TEST SYSTEM IN BUILDING 4605. SCHNEIDER IS A PHYSICIST IN THE MATERIALS AND PROCESSES DEPARTMENT AT MSFC AND IS PRINCIPAL INVESTIGATOR FOR HISET.
Porous photonic crystal external cavity laser biosensor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Qinglan; Peh, Jessie; Hergenrother, Paul J.
2016-08-15
We report the design, fabrication, and testing of a photonic crystal (PC) biosensor structure that incorporates a porous high refractive index TiO{sub 2} dielectric film that enables immobilization of capture proteins within an enhanced surface-area volume that spatially overlaps with the regions of resonant electromagnetic fields where biomolecular binding can produce the greatest shifts in photonic crystal resonant wavelength. Despite the nanoscale porosity of the sensor structure, the PC slab exhibits narrowband and high efficiency resonant reflection, enabling the structure to serve as a wavelength-tunable element of an external cavity laser. In the context of sensing small molecule interactions withmore » much larger immobilized proteins, we demonstrate that the porous structure provides 3.7× larger biosensor signals than an equivalent nonporous structure, while the external cavity laser (ECL) detection method provides capability for sensing picometer-scale shifts in the PC resonant wavelength caused by small molecule binding. The porous ECL achieves a record high figure of merit for label-free optical biosensors.« less
35. VIEW LOOKING NORTHWEST AT THE STATIC TEST TOWER. A ...
35. VIEW LOOKING NORTHWEST AT THE STATIC TEST TOWER. A 'DUMMY' SATURN I BOOSTER IS BEING HOISTED INTO THE TEST STAND TO TEST THE MATING OF THE BOOSTER AND THE TEST STAND. EARLY 1960, PHOTOGRAPHER UNKNOWN, MSFC PHOTO LAB. - Marshall Space Flight Center, Saturn Propulsion & Structural Test Facility, East Test Area, Huntsville, Madison County, AL
Enabling Exploration of Deep Space: High Density Storage of Antimatter
NASA Technical Reports Server (NTRS)
Smith, Gerald A.; Kramer, Kevin J.
1999-01-01
Portable electromagnetic antiproton traps are now in a state of realization. This allows facilities like NASA Marshall Space Flight Center to conduct antimatter research remote to production sites. MSFC is currently developing a trap to store 10(exp 12) antiprotons for a twenty-day half-life period to be used in future experiments including antimatter plasma guns, antimatter-initiated microfusion, and the synthesis of antihydrogen for space propulsion applications. In 1998, issues including design, safety and transportation were considered for the MSFC High Performance Antimatter Trap (HiPAT). Radial diffusion and annihilation losses of antiprotons prompted the use of a 4 Tesla superconducting magnet and a 20 KV electrostatic potential at 10(exp -12) Torr pressure. Cryogenic fluids used to maintain a trap temperature of 4K were sized accordingly to provide twenty days of stand-alone storage time (half-life). Procurement of the superconducting magnet with associated cryostat has been completed. The inner, ultra-high vacuum system with electrode structures has been fabricated, tested and delivered to MSFC along with the magnet and cryostat. Assembly of these systems is currently in progress. Testing under high vacuum conditions, using electrons and hydrogen ions will follow in the months ahead.
2001-01-01
A NASA team studying the causes of electrical storms and their effects on our home planet achieved a milestone on August 21, 2002, completing the study's longest-duration research flight and monitoring four thunderstorms in succession. Radio news media can talk with Dr. Richard Blakeslee, the project's principal investigator, and Tony Kim, project manager at the Marshall Space Flight Center (MSFC), about their results and how their work will help improve future weather forecasting ability. Based at the Naval Air Station Key West, Florida, researchers with the Altus Cumulus Electrification Study (ACES) used the Altus II remotely- piloted aircraft to study a thunderstorm in the Atlantic Ocean off Key West, two storms at the western edge of the Everglades, and a large storm over the northwestern corner of the Everglades. This photograph shows Tony Kim And Dr. Richard Blakeslee of MSFC testing aircraft sensors that would be used to measure the electric fields produced by thunderstorm as part of NASA's ACES. With dual goals of gathering weather data safely and testing the adaptability of the uninhabited aircraft, the ACES study is a collaboration among the MSFC, the University of Alabama in Huntsville, NASA's Goddard Space Flight Center in Greenbelt, Maryland, Pernsylvania State University in University Park, and General Atomics Aeronautical Systems, Inc.
1999-03-01
Researchers at the Marshall Space Flight Center (MSFC) have designed, fabricated, and tested the first solar thermal engine, a non-chemical rocket engine that produces lower thrust but has better thrust efficiency than a chemical combustion engine. MSFC turned to solar thermal propulsion in the early 1990s due to its simplicity, safety, low cost, and commonality with other propulsion systems. Solar thermal propulsion works by acquiring and redirecting solar energy to heat a propellant. The 20- by 24-ft heliostat mirror (not shown in this photograph) has a dual-axis control that keeps a reflection of the sunlight on the 18-ft diameter concentrator mirror, which then focuses the sunlight to a 4-in focal point inside the vacuum chamber. The focal point has 10 kilowatts of intense solar power. This image, taken during the test, depicts the light being concentrated into the focal point inside the vacuum chamber. As part of MSFC's Space Transportation Directorate, the Propulsion Research Center serves as a national resource for research of advanced, revolutionary propulsion technologies. The mission is to move the Nation's capabilities beyond the confines of conventional chemical propulsion into an era of aircraft-like access to Earth orbit, rapid travel throughout the solar system, and exploration of interstellar space.
NASA Technical Reports Server (NTRS)
Ramsey, P. E.
1976-01-01
An experimental investigation (SA14FA, TWT 620) was conducted in the MSFC 14-inch Trisonic Wind Tunnel (TWT) to determine the entry static stability of a 0.00563 scale shuttle solid rocket booster (SRB). The primary objective was to determine the effects of four side mounted sting configurations and to improve the definition of the aerodynamic characteristics in the vicinity of the SRB entry trim point. Data were obtained for two 60 and two 90 degree side mounted stings and a straight nose mounted sting. The angle of attack range for the side-mounted stings was 100 to 170 degrees while that for the nose mounted sting was 150 to 170 degrees. The Mach number range consisted of 0.6 to 3.48. Except for the aft attach ring, no protuberances were considered and the side slip and roll angles were zero. The test model was scaled from the 142-inch diameter SRB known as configuration 139 which was used during test TWT 572 (SA5F).
31. VIEW LOOKING EAST DOWN THE FLAME TRENCH OF THE ...
31. VIEW LOOKING EAST DOWN THE FLAME TRENCH OF THE STATIC TEST TOWER AS A JUPITER ROCKET IS BEING HOISTED INTO POSITION. DATE AND PHOTOGRAPHER UNKNOWN, MSFC PHOTO LAB. - Marshall Space Flight Center, Saturn Propulsion & Structural Test Facility, East Test Area, Huntsville, Madison County, AL
Youdle, Jemma; Penn, Sarah; Maunz, Olaf; Simon, Andre
2017-01-01
We report our first clinical use of the new Protek Duo TM cannula for peripheral veno-venous extra-corporeal life support (ECLS). A 53-year-old male patient underwent implantation of a total artificial heart (TAH) for biventricular failure. However, due to the development of post-operative respiratory dysfunction, the patient required ECLS for six days.
ERIC Educational Resources Information Center
Lu, Yi
2016-01-01
To model students' math growth trajectory, three conventional growth curve models and three growth mixture models are applied to the Early Childhood Longitudinal Study Kindergarten-Fifth grade (ECLS K-5) dataset in this study. The results of conventional growth curve model show gender differences on math IRT scores. When holding socio-economic…
ERIC Educational Resources Information Center
Xu, Min; Kushner Benson, Susan N.; Mudrey-Camino, Renee; Steiner, Richard P.
2010-01-01
This study examined the relationship between parental involvement, self-regulated learning (SRL), and reading achievement through analyzing the fifth grade data from the Early Childhood Longitudinal Study, Kindergarten Class of 1998-1999 (ECLS-K). The results identified six dimensions of parental involvement that are likely to foster SRL of fifth…
Hermel, Martin; Salla, Sabine; Fuest, Matthias; Walter, Peter
2017-03-01
Endothelial assessment is crucial in the release of corneas for grafting. We retrospectively analysed the role of endothelial morphology parameters in predicting endothelial cell loss during organ culture. Human donor corneas were cultured in minimal essential medium with 2% fetal calf serum and antibiotics. Initial endothelial morphology was assessed microscopically using score parameters polymegethism (POL), pleomorphism (PLE), granulation (GRA), vacuolization (VAC), segmentation of cell membranes (SEG), Descemet's folds (DF), trypan blue-positive cells (TBPC) and endothelial cell-free areas (ECFA). Some corneas were primarily rejected based on endothelial assessment. Endothelial cell density (ECD) was assessed at the beginning (I-ECD) and end of culture. Corneas were then placed in dehydration medium (as above + 5% dextran 500). In a subgroup, ECD was reassessed after dehydration. Endothelial cell loss during culture (ECL@Culture) and culture+dehydration (ECL-Culture&Dehydration) were calculated. Data were given as mean ± SD and analysed using multiple linear and logistic regression. Odds ratios (OR) and 95% confidence intervals (CI) were calculated. I-ECD was 2812 ± 360/mm 2 (n = 2356). The decision to reject a cornea due to endothelial assessment was associated negatively with I-ECD (OR = 0.77/100 cells, CI 0.7-0.82) and positively with ECFA (OR = 2.7, CI 1.69-4.35), SEG (OR =1.3, CI 1.01-1.68) and donor age (OR = 1.26/decade, CI 1.33-1.41). ECL@Culture was 153 ± 201/mm 2 (n = 1277), ECL@Culture&Dehydration was 169 ± 183/mm 2 (n = 918). ECL@Culture was associated positively with donor age, I-ECD, GRA and TBPC, and negatively with PLE, and DF. ECL@Culture&Dehydration was associated positively with age, sex, initial ECD, POL, PLE, VAC and TBPC. Morphological parameters displayed associations with the exclusion of corneas from culture and with endothelial cell loss. Appropriate parameter selection for screening purposes may help improve graft quality. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Moon, Hong Chul; Lodge, Timothy P; Frisbie, C Daniel
2014-03-05
Ion gels comprising ABA triblock copolymers and ionic liquids have received much attention as functional materials in numerous applications, especially as gate dielectrics in organic transistors. Here we have expanded the functionality of ion gels by demonstrating low-voltage, flexible electrochemiluminescent (ECL) devices using patterned ion gels containing redox-active luminophores. The ECL devices consisted only of a 30 μm thick emissive gel and two electrodes and were fabricated on indium tin oxide-coated substrates (e.g., polyester) simply by solution-casting the ECL gel and brush-painting a top Ag electrode. The triblock copolymer employed in the gel was polystyrene-block-poly(methyl methacrylate)-block-polystyrene, where the solvophobic polystyrene end blocks associate into micellar cross-links in the versatile ionic liquid 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([EMI][TFSI]). An ECL gel containing ~6.25 wt % Ru(bpy)3Cl2 (relative to [EMI][TFSI]) as the luminophore turned on at an AC peak-to-peak voltage as low as 2.6 V (i.e., -1.3 to +1.3 V) and showed a relatively rapid response (sub-ms). The wavelength of maximum emission was 610 nm (red-orange). With the use of an iridium(III) complex, Ir(diFppy)2(bpy)PF6 [diFppy = 2-(2',4'-difluorophenyl)pyridine; bpy = 2,2'-bipyridyl], the emitting color was tuned to a maximum wavelength of 540 nm (green). Moreover, when a blended luminophore system containing a 60:40 mixture of Ru(bpy)3(2+) and Ir(diFppy)2(bpy)(+) was used in the emissive layer, the luminance of red-orange-colored light was enhanced by a factor of 2, which is explained by the generation of the additional excited state Ru(bpy)3(2+)* by a coreactant pathway with Ir(diFppy)2(bpy)(+)* in addition to the usual annihilation pathway. This is the first time that enhanced ECL has been achieved in ion gels (or ionic liquids) using a coreactant. Overall, the results indicate that ECL ion gels are attractive multifunctional materials for printed electronics.
2017-07-10
The Orion stage adapter is being positioned for lifting onto the loading platform before being loaded into NASA's Super Guppie aircraft. The adapter will be flown to Denver, Colorado for further testing.
2017-07-10
The Orion stage adapter is being positioned for lifting onto the loading platform before being loaded into NASA's Super Guppie aircraft. The adapter will be flown to Denver, Colorado for further testing.
2017-07-10
The Orion stage adapter is being positioned for lifting onto the loading platform before being loaded into NASA's Super Guppie aircraft. The adapter will be flown to Denver, Colorado for further testing.
2017-07-10
The Orion stage adapter is being positioned for lifting onto the loading platform before being loaded into NASA's Super Guppie aircraft. The adapter will be flown to Denver, Colorado for further testing.
2017-07-10
The Orion stage adapter is being positioned for lifting onto the loading platform before being loaded into NASA's Super Guppie aircraft. The adapter will be flown to Denver, Colorado for further testing.
2017-07-10
The Orion stage adapter is being positioned for lifting onto the loading platform before being loaded into NASA's Super Guppie aircraft. The adapter will be flown to Denver, Colorado for further testing.
2017-07-10
The Orion stage adapter is being positioned for lifting onto the loading platform before being loaded into NASA's Super Guppie aircraft. The adapter will be flown to Denver, Colorado for further testing.
Results and Interpretation of the WFRD ELS Distillation Down-Select Test Data
NASA Technical Reports Server (NTRS)
Delzeit, Lance Dean; Flynn, Michael; Carter, Layne; Long, David A.
2010-01-01
Testing of the Wiped-film Rotating-disk (WFRD) evaporator was conducted in support of the Exploration Life Support Distillation Down-Select Test. The WFRD was constructed at NASA Ames Research Center (ARC) and tested at NASA Marshall Space Flight Center (MSFC). The WFRD was delivered to MSFC in September 2009, and testing of solution #1 and solution #2 immediately following. Solution #1 was composed of humidity condensate and urine, including flush water and pretreatment chemicals. Solution #2 was composed of hygiene water, humidity condensate, and urine, including flush water and pretreatment chemicals. During the testing, the operational parameters of the WFRD were recorded and samples of the feed, brine, and product were collected and analyzed. The steady-state results of processing 414L of feed solution #1 and 1283L of feed solution #2 demonstrated that running the WFRD at a brine temperature of 50 C gave an average production rate of 16.7 L/hr. The specific energy consumption was 80.5W-hr/L. Data Analysis shows that the water recovery rates were 94% and 91%, respectively. The total mass of the WFRD as delivered to MSFC was 300 Kg. The volume of the tests stand rack was 1m width x 0.7m depth x 1.9m height or 1.5 cu m of which about half of the total volume is occupied by equipment. Chemical analysis of the distillate showed an average TOC of 20ppm, a pH of 3.5, and a conductivity of 98 mho/cm. The conductivity of the distillate, compared to the feed, decreased by 98.9%., the total ion concentration decreased by 99.6%, the total organics decreased 98.6%, and the metals were at or below detection limits