Prospects for a Muon Spin Resonance Facility in the MuCool Test Area
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnstone, John A.
2017-04-12
This paper investigates the feasibility of re-purposing the MuCool Test Area beamline and experimental hall to support a Muon Spin Resonance facility, which would make it the only such facility in the US. This report reviews the basic muon production concepts studied and operationally implemented at TRIUMF, PSI, and RAL and their application to the MTA facility. Two scenarios were determined feasible. One represents an initial minimal-shielding and capital-cost investment stage with a single secondary muon beamline that transports the primary beam to an existing high-intensity beam absorber located outside of the hall. Another, upgraded stage, involves an optimized productionmore » target pile and high-intensity absorber installed inside the experimental hall and potentially multiple secondary muon lines. In either scenario, with attention to target design, the MTA can host enabling and competitive Muon Spin Resonance experiments« less
Muon Accelerator Program (MAP) | Neutrino Factory | Research Goals
; Committees Research Goals Research & Development Design & Simulation Technology Development Systems Demonstrations Activities MASS Muon Cooling MuCool Test Area MICE Experiment MERIT Muon Collider Research Goals Why Muons at the Energy Frontier? How does it work? Graphics Animation Neutrino Factory Research Goals
Prospects for a Muon Spin Resonance Facility in the Fermilab MuCool Test Area
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnstone, John A.; Johnstone, Carol
This paper investigates the feasibility of re-purposing the MuCool Test Area (MTA) beamline and experimental hall to support a Muon Spin Resonance (MuSR) facility, which would make it the only such facility in the US. This report reviews the basic muon production concepts studied and operationally implemented at TRIUMF, PSI, and RAL and their application in the context of the MTA facility. Two scenarios were determined feasible. One, an initial minimal-shielding and capital-cost investment stage with a single secondary muon beamline that utilizes an existing high- intensity beam absorber and, another, upgraded stage, that implements an optimized production target pile,more » a proximate high-intensity absorber, and optimized secondary muon lines. A unique approach is proposed which chops or strips a macropulse of H$^-$ beam into a micropulse substructure – a muon creation timing scheme – which allows Muon Spin Resonance experiments in a linac environment. With this timing scheme, and attention to target design and secondary beam collection, the MTA can host enabling and competitive Muon Spin Resonance experiments.« less
Cryogenics for the MuCool Test Area (MTA)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Darve, Christine; Norris, Barry; Pei, Liu-Jin
2005-09-01
MuCool Test Area (MTA) is a complex of buildings at Fermi National Accelerator Laboratory, which are dedicated to operate components of a cooling cell to be used for Muon Collider and Neutrino Factory R&D. The long-term goal of this facility is to test ionization cooling principles by operating a 25-liter liquid hydrogen (LH{sub 2}) absorber embedded in a 5 Tesla superconducting solenoid magnet. The MTA solenoid magnet will be used with RF cavities exposed to a high intensity beam. Cryogens used at the MTA include LHe, LN{sub 2} and LH{sub 2}. The latter dictates stringent system design for hazardous locations.more » The cryogenic plant is a modified Tevatron refrigerator based on the Claude cycle. The implementation of an in-house refrigerator system and two 300 kilowatt screw compressors is under development. The helium refrigeration capacity is 500 W at 14 K. In addition the MTA solenoid magnet will be batch-filled with LHe every 2 days using the same cryo-plant. This paper reviews cryogenic systems used to support the Muon Collider and Neutrino Factory R&D programs and emphasizes the feasibility of handling cryogenic equipment at MTA in a safe manner.« less
Cryogenics for the MuCool Test Area (MTA)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Darve, Christine; Norris, Barry; Pei, Liujin
2006-03-20
MuCool Test Area (MTA) is a complex of buildings at Fermi National Accelerator Laboratory, which are dedicated to operate components of a cooling cell to be used for Muon Collider and Neutrino Factory R and D. The long-term goal of this facility is to test ionization cooling principles by operating a 25-liter liquid hydrogen (LH2) absorber embedded in a 5 Tesla superconducting solenoid magnet. The MTA solenoid magnet will be used with RF cavities exposed to a high intensity beam. Cryogens used at the MTA include LHe, LN2 and LH2. The latter dictates stringent system design for hazardous locations. Themore » cryogenic plant is a modified Tevatron refrigerator based on the Claude cycle. The implementation of an in-house refrigerator system and two 300 kilowatt screw compressors is under development. The helium refrigeration capacity is 500 W at 14 K. In addition the MTA solenoid magnet will be batch-filled with LHe every 2 days using the same cryo-plant. This paper reviews cryogenic systems used to support the Muon Collider and Neutrino Factory R and D programs and emphasizes the feasibility of handling cryogenic equipment at MTA in a safe manner.« less
Gas Filled RF Resonator Hadron Beam Monitor for Intense Neutrino Beam Experiments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yonehara, Katsuya; Abrams, Robert; Dinkel, Holly
MW-class beam facilities are being considered all over the world to produce an intense neutrino beam for fundamental particle physics experiments. A radiation-robust beam monitor system is required to diagnose the primary and secondary beam qualities in high-radiation environments. We have proposed a novel gas-filled RF-resonator hadron beam monitor in which charged particles passing through the resonator produce ionized plasma that changes the permittivity of the gas. The sensitivity of the monitor has been evaluated in numerical simulation. A signal manipulation algorithm has been designed. A prototype system will be constructed and tested by using a proton beam at themore » MuCool Test Area at Fermilab.« less
Beam Test of a Dielectric Loaded High Pressure RF Cavity for Use in Muon Cooling Channels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Freemire, Ben; Bowring, Daniel; Kochemirovskiy, Alexey
2016-06-01
Bright muon sources require six dimensional cooling to achieve acceptable luminosities. Ionization cooling is the only known method able to do so within the muon lifetime. One proposed cooling channel, the Helical Cooling Channel, utilizes gas filled radio frequency cavities to both mitigate RF breakdown in the presence of strong, external magnetic fields, and provide the cooling medium. Engineering constraints on the diameter of the magnets within which these cavities operate dictate the radius of the cavities be decreased at their nominal operating frequency. To accomplish this, one may load the cavities with a larger dielectric material. A 99.5% aluminamore » ring was inserted in a high pressure RF test cell and subjected to an intense proton beam at the MuCool Test Area at Fermilab. The results of the performance of this dielectric loaded high pressure RF cavity will be presented.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bowring, Daniel; Freemire, Ben; Kochemirovskiy, Alexey
Ionization cooling of intense muon beams requires the operation of high-gradient, normal-conducting RF structures within multi-Tesla magnetic fields. The application of strong magnetic fields has been shown to lead to an increase in vacuum RF breakdown. This phenomenon imposes operational (i.e. gradient) limitations on cavities in ionization cooling channels, and has a bearing on the design and operation of other RF structures as well, such as photocathodes and klystrons. We present recent results from Fermilab's MuCool Test Area (MTA), in which 201 and 805 MHz cavities were operated at high power both with and without the presence of multi-Tesla magneticmore » fields. We present an analysis of damage due to breakdown in these cavities, as well as measurements related to dark current and their relation to a conceptual model describing breakdown phenomena.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Freemire, Ben; Bowring, Daniel; Kochemirovskiy, Alexey
Bright muon sources require six dimensional cooling to achieve acceptable luminosities. Ionization cooling is the only known method able to do so within the muon lifetime. One proposed cooling channel, the Helical Cooling Channel, utilizes gas filled radio frequency cavities to both mitigate RF breakdown in the presence of strong, external magnetic fields, and provide the cooling medium. Engineering constraints on the diameter of the magnets within which these cavities operate dictate the radius of the cavities be decreased at their nominal operating frequency. To accomplish this, one may load the cavities with a larger dielectric material. Alumina of puritiesmore » ranging from 96 to 99.8% was tested in a high pressure RF test cell at the MuCool Test Area at Fermilab. The results of breakdown studies with pure nitrogen gas, and oxygen-doped nitrogen gas indicate the peak surface electric field on the alumina ranges between 10 and 15 MV/m. How these results affect the design of a prototype cooling channel cavity will be discussed.« less
Simulation of beam-induced plasma in gas-filled rf cavities
Yu, Kwangmin; Samulyak, Roman; Yonehara, Katsuya; ...
2017-03-07
Processes occurring in a radio-frequency (rf) cavity, filled with high pressure gas and interacting with proton beams, have been studied via advanced numerical simulations. Simulations support the experimental program on the hydrogen gas-filled rf cavity in the Mucool Test Area (MTA) at Fermilab, and broader research on the design of muon cooling devices. space, a 3D electromagnetic particle-in-cell (EM-PIC) code with atomic physics support, was used in simulation studies. Plasma dynamics in the rf cavity, including the process of neutral gas ionization by proton beams, plasma loading of the rf cavity, and atomic processes in plasma such as electron-ion andmore » ion-ion recombination and electron attachment to dopant molecules, have been studied. Here, through comparison with experiments in the MTA, simulations quantified several uncertain values of plasma properties such as effective recombination rates and the attachment time of electrons to dopant molecules. Simulations have achieved very good agreement with experiments on plasma loading and related processes. Lastly, the experimentally validated code space is capable of predictive simulations of muon cooling devices.« less
High Pressure Gas Filled RF Cavity Beam Test at the Fermilab MuCool Test Area
DOE Office of Scientific and Technical Information (OSTI.GOV)
Freemire, Ben
2013-05-01
The high energy physics community is continually looking to push the limits with respect to the energy and luminosity of particle accelerators. In the realm of leptons, only electron colliders have been built to date. Compared to hadrons, electrons lose a large amount of energy when accelerated in a ring through synchrotron radiation. A solution to this problem is to build long, straight accelerators for electrons, which has been done with great success. With a new generation of lepton colliders being conceived, building longer, more powerful accelerators is not the most enticing option. Muons have been proposed as an alternativemore » particle to electrons. Muons lose less energy to synchrotron radiation and a Muon Collider can provide luminosity within a much smaller energy range than a comparable electron collider. This allows a circular collider to be built with higher attainable energy than any present electron collider. As part of the accelerator, but separate from the collider, it would also be possible to allow the muons to decay to study neutrinos. The possibility of a high energy, high luminosity muon collider and an abundant, precise source of neutrinos is an attractive one. The technological challenges of building a muon accelerator are many and diverse. Because the muon is an unstable particle, a muon beam must be cooled and accelerated to the desired energy within a short amount of time. This requirement places strict requisites on the type of acceleration and focusing that can be used. Muons are generated as tertiary beams with a huge phase space, so strong magnetic fields are required to capture and focus them. Radio frequency (RF) cavities are needed to capture, bunch and accelerate the muons. Unfortunately, traditional vacuum RF cavities have been shown to break down in the magnetic fields necessary for capture and focusing.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, Rolland
Many present and future particle accelerators are limited by the maximum electric gradient and peak surface fields that can be realized in RF cavities. Despite considerable effort, a comprehensive theory of RF breakdown has not been achieved and mitigation techniques to improve practical maximum accelerating gradients have had only limited success. Part of the problem is that RF breakdown in an evacuated cavity involves a complex mixture of effects, which include the geometry, metallurgy, and surface preparation of the accelerating structures and the make-up and pressure of the residual gas in which plasmas form. Studies showed that high gradients canmore » be achieved quickly in 805 MHz RF cavities pressurized with dense hydrogen gas, as needed for muon cooling channels, without the need for long conditioning times, even in the presence of strong external magnetic fields. This positive result was expected because the dense gas can practically eliminate dark currents and multipacting. In this project we used this high pressure technique to suppress effects of residual vacuum and geometry that are found in evacuated cavities in order to isolate and study the role of the metallic surfaces in RF cavity breakdown as a function of magnetic field, frequency, and surface preparation. One of the interesting and useful outcomes of this project was the unanticipated collaborations with LANL and Fermilab that led to new insights as to the operation of evacuated normal-conducting RF cavities in high external magnetic fields. Other accomplishments included: (1) RF breakdown experiments to test the effects of SF6 dopant in H2 and He gases with Sn, Al, and Cu electrodes were carried out in an 805 MHz cavity and compared to calculations and computer simulations. The heavy corrosion caused by the SF6 components led to the suggestion that a small admixture of oxygen, instead of SF6, to the hydrogen would allow the same advantages without the corrosion in a practical muon beam line. (2) A 1.3 GHz RF test cell capable of operating both at high pressure and in vacuum with replaceable electrodes was designed, built, and power tested in preparation for testing the frequency and geometry effects of RF breakdown at Argonne National Lab. At the time of this report this cavity is still waiting for the 1.3 GHz klystron to be available at the Wakefield Test Facility. (3) Under a contract with Los Alamos National Lab, an 805 MHz RF test cavity, known as the All-Seasons Cavity (ASC), was designed and built by Muons, Inc. to operate either at high pressure or under vacuum. The LANL project to use the (ASC) was cancelled and the testing of the cavity has been continued under the grant reported on here using the Fermilab Mucool Test Area (MTA). The ASC is a true pillbox cavity that has performed under vacuum in high external magnetic field better than any other and has demonstrated that the high required accelerating gradients for many muon cooling beam line designs are possible. (4) Under ongoing support from the Muon Acceleration Program, microscopic surface analysis and computer simulations have been used to develop models of RF breakdown that apply to both pressurized and vacuum cavities. The understanding of RF breakdown will lead to better designs of RF cavities for many applications. An increase in the operating accelerating gradient, improved reliability and shorter conditioning times can generate very significant cost savings in many accelerator projects.« less
NASA Technical Reports Server (NTRS)
Springer, Darlene
1989-01-01
Different aspects of Space Station Environmental Control and Life Support System (ECLSS) testing are currently taking place at Marshall Space Flight Center (MSFC). Unique to this testing is the variety of test areas and the fact that all are located in one building. The north high bay of building 4755, the Core Module Integration Facility (CMIF), contains the following test areas: the Subsystem Test Area, the Comparative Test Area, the Process Material Management System (PMMS), the Core Module Simulator (CMS), the End-use Equipment Facility (EEF), and the Pre-development Operational System Test (POST) Area. This paper addresses the facility that supports these test areas and briefly describes the testing in each area. Future plans for the building and Space Station module configurations will also be discussed.
11. "NIGHT SCENE OF TEST AREA WITH TEST STAND 1A ...
11. "NIGHT SCENE OF TEST AREA WITH TEST STAND 1-A IN FOREGROUND. LIGHTS OF MAIN BASE, EDWARDS AFB, IN THE BACKGROUND. EDWARDS AFB." Test Area 1-120. Looking west past Test Stand 1-A to Test Area 1-115 and Test Area 1-110. Photo no. "12,401 57; G-AFFTC 12 DEC 57; TS 1-A Aux #1". - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Leuhman Ridge near Highways 58 & 395, Boron, Kern County, CA
4. TEST AREA 1120 OVERVIEW, TEST AREA 1115 IN MIDDLE ...
4. TEST AREA 1-120 OVERVIEW, TEST AREA 1-115 IN MIDDLE DISTANCE, AND TEST AREA 1-110 IN FAR DISTANCE AT EXTREME LEFT. ROGERS DRY LAKE AND THE HANGARS AT MAIN BASE ARE VISIBLE IN THE FAR RIGHT DISTANCE. TEST STANDS 2-A AND 1-A ARE NEAREST THE CAMERA. Looking west southwest. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Leuhman Ridge near Highways 58 & 395, Boron, Kern County, CA
33 CFR 334.30 - Gulf of Maine off Pemaquid Point, Maine; naval sonobuoy test area.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., Maine; naval sonobuoy test area. 334.30 Section 334.30 Navigation and Navigable Waters CORPS OF....30 Gulf of Maine off Pemaquid Point, Maine; naval sonobuoy test area. (a) The area. The test area or... enforced by the Commanding Officer, U.S. Naval Air Station, Brunswick, Maine, or such agencies as he may...
33 CFR 334.30 - Gulf of Maine off Pemaquid Point, Maine; naval sonobuoy test area.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., Maine; naval sonobuoy test area. 334.30 Section 334.30 Navigation and Navigable Waters CORPS OF....30 Gulf of Maine off Pemaquid Point, Maine; naval sonobuoy test area. (a) The area. The test area or... enforced by the Commanding Officer, U.S. Naval Air Station, Brunswick, Maine, or such agencies as he may...
33 CFR 334.30 - Gulf of Maine off Pemaquid Point, Maine; naval sonobuoy test area.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., Maine; naval sonobuoy test area. 334.30 Section 334.30 Navigation and Navigable Waters CORPS OF....30 Gulf of Maine off Pemaquid Point, Maine; naval sonobuoy test area. (a) The area. The test area or... enforced by the Commanding Officer, U.S. Naval Air Station, Brunswick, Maine, or such agencies as he may...
33 CFR 334.30 - Gulf of Maine off Pemaquid Point, Maine; naval sonobuoy test area.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., Maine; naval sonobuoy test area. 334.30 Section 334.30 Navigation and Navigable Waters CORPS OF....30 Gulf of Maine off Pemaquid Point, Maine; naval sonobuoy test area. (a) The area. The test area or... enforced by the Commanding Officer, U.S. Naval Air Station, Brunswick, Maine, or such agencies as he may...
33 CFR 334.30 - Gulf of Maine off Pemaquid Point, Maine; naval sonobuoy test area.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., Maine; naval sonobuoy test area. 334.30 Section 334.30 Navigation and Navigable Waters CORPS OF....30 Gulf of Maine off Pemaquid Point, Maine; naval sonobuoy test area. (a) The area. The test area or... enforced by the Commanding Officer, U.S. Naval Air Station, Brunswick, Maine, or such agencies as he may...
40 CFR 792.43 - Test system care facilities.
Code of Federal Regulations, 2014 CFR
2014-07-01
.... (a) A testing facility shall have a sufficient number of animal rooms or other test system areas, as... accomplished within a room or area by housing them separately in different chambers or aquaria. Separation of... different tests. (b) A testing facility shall have a number of animal rooms or other test system areas...
40 CFR 792.43 - Test system care facilities.
Code of Federal Regulations, 2012 CFR
2012-07-01
.... (a) A testing facility shall have a sufficient number of animal rooms or other test system areas, as... accomplished within a room or area by housing them separately in different chambers or aquaria. Separation of... different tests. (b) A testing facility shall have a number of animal rooms or other test system areas...
40 CFR 792.43 - Test system care facilities.
Code of Federal Regulations, 2013 CFR
2013-07-01
.... (a) A testing facility shall have a sufficient number of animal rooms or other test system areas, as... accomplished within a room or area by housing them separately in different chambers or aquaria. Separation of... different tests. (b) A testing facility shall have a number of animal rooms or other test system areas...
5. PRELIMINARY SKETCH OF THE GUIDED MISSILE TEST FACILITIES FOR ...
5. PRELIMINARY SKETCH OF THE GUIDED MISSILE TEST FACILITIES FOR TEST AREA NUMBER 2. TODAY IR IS KNOWN AS MARSHALL SPACE FLIGHT CENTER'S EAST TEST AREA. HANNES LUEHRSEN COLLECTION, MSFC MASTER PLANNING OFFICE. - Marshall Space Flight Center, East Test Area, Dodd Road, Huntsville, Madison County, AL
7. "AERIAL VIEW OF THE TEST AREA, DIRECTORATE OF MISSILE ...
7. "AERIAL VIEW OF THE TEST AREA, DIRECTORATE OF MISSILE CAPTIVE TEST, EDWARDS AFB. 8 AUG 57." In upper left corner, photo no. "8462 57" cropped out: "A-AFFTC 8 AUG 57, RETL TEST AREA" This photo is a high oblique view, showing the wing of the photo plane and Test Area 1-115. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Leuhman Ridge near Highways 58 & 395, Boron, Kern County, CA
Code of Federal Regulations, 2011 CFR
2011-07-01
..., Fla.; Air Force missile testing area, Patrick Air Force Base, Fla. 334.590 Section 334.590 Navigation... RESTRICTED AREA REGULATIONS § 334.590 Atlantic Ocean off Cape Canaveral, Fla.; Air Force missile testing area... during firing periods to be specified by the Commander, Air Force Missile Test Center, Patrick Air Force...
Code of Federal Regulations, 2013 CFR
2013-07-01
..., Fla.; Air Force missile testing area, Patrick Air Force Base, Fla. 334.590 Section 334.590 Navigation... RESTRICTED AREA REGULATIONS § 334.590 Atlantic Ocean off Cape Canaveral, Fla.; Air Force missile testing area... during firing periods to be specified by the Commander, Air Force Missile Test Center, Patrick Air Force...
Code of Federal Regulations, 2012 CFR
2012-07-01
..., Fla.; Air Force missile testing area, Patrick Air Force Base, Fla. 334.590 Section 334.590 Navigation... RESTRICTED AREA REGULATIONS § 334.590 Atlantic Ocean off Cape Canaveral, Fla.; Air Force missile testing area... during firing periods to be specified by the Commander, Air Force Missile Test Center, Patrick Air Force...
Code of Federal Regulations, 2014 CFR
2014-07-01
..., Fla.; Air Force missile testing area, Patrick Air Force Base, Fla. 334.590 Section 334.590 Navigation... RESTRICTED AREA REGULATIONS § 334.590 Atlantic Ocean off Cape Canaveral, Fla.; Air Force missile testing area... during firing periods to be specified by the Commander, Air Force Missile Test Center, Patrick Air Force...
12 CFR 563e.23 - Investment test.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Investment test. 563e.23 Section 563e.23 Banks... for Assessing Performance § 563e.23 Investment test. (a) Scope of test. The investment test evaluates... qualified investments that benefit its assessment area(s) or a broader statewide or regional area that...
Energy Systems Test Area (ESTA). Power Systems Test Facilities
NASA Technical Reports Server (NTRS)
Situ, Cindy H.
2010-01-01
This viewgraph presentation provides a detailed description of the Johnson Space Center's Power Systems Facility located in the Energy Systems Test Area (ESTA). Facilities and the resources used to support power and battery systems testing are also shown. The contents include: 1) Power Testing; 2) Power Test Equipment Capabilities Summary; 3) Source/Load; 4) Battery Facilities; 5) Battery Test Equipment Capabilities Summary; 6) Battery Testing; 7) Performance Test Equipment; 8) Battery Test Environments; 9) Battery Abuse Chambers; 10) Battery Abuse Capabilities; and 11) Battery Test Area Resources.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., Fla.; Air Force missile testing area, Patrick Air Force Base, Fla. 334.590 Section 334.590 Navigation... RESTRICTED AREA REGULATIONS § 334.590 Atlantic Ocean off Cape Canaveral, Fla.; Air Force missile testing area, Patrick Air Force Base, Fla. (a) The danger zone. An area in the Atlantic Ocean immediately offshore from...
6. PRELIMINARY SKETCH FOR A NEW REDSTONE ARSENAL HEADQUARTERS AND ...
6. PRELIMINARY SKETCH FOR A NEW REDSTONE ARSENAL HEADQUARTERS AND ENGINEERING AREA. (PRESENT DAY MARSHALL SPACE FLIGHT CENTER), INCLUDING TEST AREA NUMBER 2 (MSFC, EAST TEST AREA). SEPTEMBER 1951, HANNES LUEHRSEN COLLECTION, MSFC MASTER PLANNING OFFICE. - Marshall Space Flight Center, East Test Area, Dodd Road, Huntsville, Madison County, AL
1. VIEW EAST, COMPONENTS TEST LABORATORY SHOWING CATCH BASINS, TURBINE ...
1. VIEW EAST, COMPONENTS TEST LABORATORY SHOWING CATCH BASINS, TURBINE TESTING AREA, AND PUMP TESTING TOWER. - Marshall Space Flight Center, East Test Area, Components Test Laboratory, Huntsville, Madison County, AL
14 CFR 91.305 - Flight test areas.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 2 2012-01-01 2012-01-01 false Flight test areas. 91.305 Section 91.305... AND GENERAL OPERATING RULES GENERAL OPERATING AND FLIGHT RULES Special Flight Operations § 91.305 Flight test areas. No person may flight test an aircraft except over open water, or sparsely populated...
14 CFR 91.305 - Flight test areas.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 2 2013-01-01 2013-01-01 false Flight test areas. 91.305 Section 91.305... AND GENERAL OPERATING RULES GENERAL OPERATING AND FLIGHT RULES Special Flight Operations § 91.305 Flight test areas. No person may flight test an aircraft except over open water, or sparsely populated...
14 CFR 91.305 - Flight test areas.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Flight test areas. 91.305 Section 91.305... AND GENERAL OPERATING RULES GENERAL OPERATING AND FLIGHT RULES Special Flight Operations § 91.305 Flight test areas. No person may flight test an aircraft except over open water, or sparsely populated...
LPT. Aerial of low power test (TAN640 and 641) and ...
LPT. Aerial of low power test (TAN-640 and -641) and shield test (TAN-645 and -646) facilities. Camera facing north west. Low power test facility at right. Shield test facility at left. Flight engine test area in background at center left of view. Administrative and A&M areas at right. Photographer: Lowin. Date: February 24, 1965. INEEL negative no. 65-991 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
Methods of Passing Vehicles Over Areas Similar in Character to Rice Paddy Fields
1945-01-02
Test Branch in specially prepared mud areas, some of which had been planted with rice and hemp . 3. From these and previous tests it is concluded in...0.005m). The Liquid Limit was 21j Plastic Limit, 16j Plasticity Index, 6. The test areas are listed as follows» a. One area 100 by 300...feet prepared for immediate use far "go - no go" tests. b. Twe areas 90 by 210 feet each, one planted with rice and the other planted with hemp , for
Small UAS Test Area at NASA's Dryden Flight Research Center
NASA Technical Reports Server (NTRS)
Bauer, Jeffrey T.
2008-01-01
This viewgraph presentation reviews the areas that Dryden Flight Research Center has set up for testing small Unmanned Aerial Systems (UAS). It also reviews the requirements and process to use an area for UAS test.
VIEW OF EAST TEST SITE FROM TOP OF STATIC TEST ...
VIEW OF EAST TEST SITE FROM TOP OF STATIC TEST TOWER VIEW INCLUDES POWER PLANT TEST STAND AND SATURN V TEST STAND IN THE WEST TEST AREA (FAR BACKGROUND). - Marshall Space Flight Center, East Test Area, Dodd Road, Huntsville, Madison County, AL
Fernandes, Kimberly A; Sutradhar, Rinku; Borkhoff, Cornelia M; Baxter, Nancy; Lofters, Aisha; Rabeneck, Linda; Tinmouth, Jill; Paszat, Lawrence
2015-01-01
Screening for cervical, breast and colon cancers, and elevations of cholesterol and glucose, reduces premature cause-specific mortality from these cancers and circulatory diseases. Despite primary care reforms and incentives, and promotion of cancer-screening programs among individuals, participation is suboptimal. We aimed to examine participation as of Dec. 31, 2011, by factors of deprivation, demographics and primary care at the small-area level. From health care administrative databases, we identified people eligible for each screening test, and their participation, in each dissemination area (referred to as small areas, n = 18 950) in Ontario. We calculated rates for each test among small areas (overall and stratified by demographic, socioeconomic and primary care descriptors) and stratified by sex for all tests combined. We loaded all data into a geographic information system. Funnel plots were generated showing the percentage of eligible people who completed screening for all tests by small area, stratified by sex. Overall and stratified screening prevalence ratios were calculated among small areas. Among small areas, the mean and SD for participation in all tests combined was 31.6% (SD 11.0%) for women and 41.2% (SD 12.0%) for men. Screening prevalence among small areas, for each test and for all tests combined, overall and stratified by sex, declined with decreasing percentage with high school completion, decreasing socioeconomic quintile, and decreasing percentage with an identifiable primary care physician. Our results show that the rate of participation in all eligible screening tests among small areas is much lower than the rate of participation in any one particular test. This finding has implications for the design and implementation of strategies to improve rates of screening.
TEST REACTOR AREA PLOT PLAN CA. 1968. MTR AND ETR ...
TEST REACTOR AREA PLOT PLAN CA. 1968. MTR AND ETR AREAS SOUTH OF PERCH AVENUE. "COLD" SERVICES NORTH OF PERCH. ADVANCED TEST REACTOR IN NEW SECTION WEST OF COLD SERVICES SECTION. NEW PERIMETER FENCE ENCLOSES BETA RAY SPECTROMETER, TRA-669, AN ATR SUPPORT FACILITY, AND ATR STACK. UTM LOCATORS HAVE BEEN DELETED. IDAHO NUCLEAR CORPORATION, FROM A BLAW-KNOX DRAWING, 3/1968. INL INDEX NO. 530-0100-00-400-011646, REV. 0. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
40 CFR 160.43 - Test system care facilities.
Code of Federal Regulations, 2013 CFR
2013-07-01
... facility shall have a sufficient number of animal rooms or other test system areas, as needed, to ensure... a room or area by housing them separately in different chambers or aquaria. Separation of species is... testing facility shall have a number of animal rooms or other test system areas separate from those...
40 CFR 160.43 - Test system care facilities.
Code of Federal Regulations, 2014 CFR
2014-07-01
... facility shall have a sufficient number of animal rooms or other test system areas, as needed, to ensure... a room or area by housing them separately in different chambers or aquaria. Separation of species is... testing facility shall have a number of animal rooms or other test system areas separate from those...
A test manager's perspective of a test concept for a heavy lift vehicle
NASA Technical Reports Server (NTRS)
Pargeon, John I., Jr.
1990-01-01
The developmment of a test concept is a significant part of the advanced planning activities accomplished for the Initial Operational Test and Evaluation (IOT&E) of new systems. A test concept is generally viewed as a description, including rationale, of the test structure, evaluation methodology and management approach required to plan and conduct the IOT&E of a program such as a new heavy lift launch vehicle system. The test concept as presented in this paper is made up of an operations area, a test area, an evaluation area, and a management area. The description presented here is written from the perspective of one test manager, and represents his views of a possible framework of a test concept using examples for a potential IOT&E of a heavy lift launch vehicle.
1. TEST AREA 1115, SOUTH PART OF SUPPORT COMPLEX, LOOKING ...
1. TEST AREA 1-115, SOUTH PART OF SUPPORT COMPLEX, LOOKING TO EAST FROM ABOVE BUILDING 8655, THE FUEL STORAGE TANK FARM, IN FOREGROUND SHADOW. AT THE RIGHT IS BUILDING 8660, ELECTRICAL SUBSTATION; TO ITS LEFT IS BUILDING 8663, THE HELIUM COMPRESSION PLANT. THE LIGHT TONED STRUCTURE IN THE MIDDLE DISTANCE, CENTER, IS THE MACHINE SHOP FOR TEST STAND 1-3. IN THE FAR DISTANCE IS TEST STAND 1-A, WITH THE WHITE SPHERICAL TANKS, AND TEST STAND 2-A TO ITS RIGHT. ALONG THE HORIZON FROM FAR LEFT ARE TEST STAND 1-D, TEST STAND 1-C, WATER TANKS ABOVE TEST AREA 1-125, AND TEST STAND 1-B IN TEST AREA 1-120. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Leuhman Ridge near Highways 58 & 395, Boron, Kern County, CA
33 CFR 334.1440 - Pacific Ocean at Kwajalein Atoll, Marshall Islands; missile testing area.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., Marshall Islands; missile testing area. 334.1440 Section 334.1440 Navigation and Navigable Waters CORPS OF....1440 Pacific Ocean at Kwajalein Atoll, Marshall Islands; missile testing area. (a) The warning area...°43′00″ N., longitude 167°43′00″ E. Intermittent hazardous missile operations will be conducted within...
33 CFR 334.1440 - Pacific Ocean at Kwajalein Atoll, Marshall Islands; missile testing area.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., Marshall Islands; missile testing area. 334.1440 Section 334.1440 Navigation and Navigable Waters CORPS OF....1440 Pacific Ocean at Kwajalein Atoll, Marshall Islands; missile testing area. (a) The warning area...°43′00″ N., longitude 167°43′00″ E. Intermittent hazardous missile operations will be conducted within...
33 CFR 334.1440 - Pacific Ocean at Kwajalein Atoll, Marshall Islands; missile testing area.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., Marshall Islands; missile testing area. 334.1440 Section 334.1440 Navigation and Navigable Waters CORPS OF....1440 Pacific Ocean at Kwajalein Atoll, Marshall Islands; missile testing area. (a) The warning area...°43′00″ N., longitude 167°43′00″ E. Intermittent hazardous missile operations will be conducted within...
33 CFR 334.1440 - Pacific Ocean at Kwajalein Atoll, Marshall Islands; missile testing area.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., Marshall Islands; missile testing area. 334.1440 Section 334.1440 Navigation and Navigable Waters CORPS OF....1440 Pacific Ocean at Kwajalein Atoll, Marshall Islands; missile testing area. (a) The warning area...°43′00″ N., longitude 167°43′00″ E. Intermittent hazardous missile operations will be conducted within...
33 CFR 334.1440 - Pacific Ocean at Kwajalein Atoll, Marshall Islands; missile testing area.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., Marshall Islands; missile testing area. 334.1440 Section 334.1440 Navigation and Navigable Waters CORPS OF....1440 Pacific Ocean at Kwajalein Atoll, Marshall Islands; missile testing area. (a) The warning area...°43′00″ N., longitude 167°43′00″ E. Intermittent hazardous missile operations will be conducted within...
Pérez, Alicia; Costa, María T; Cantoni, Gustavo; Mancini, Sergio; Mercapide, Carlos; Herrero, Eduardo; Volpe, Marcela; Araya, Daniel; Talmon, Gabriel; Chiosso, Carlos; Vázquez, Gabriela; Del Carpio, Mario; Santillan, Graciela; Larrieu, Edmundo
2006-01-01
The surveillance of infection for Echinococcus granulosus in the Province of Rio Negro during 1980-2002 included serological and ultrasonographic screening in humans and arecoline test in dogs. In lieu of the limitations of the arecoline test the proposal was to supplant that test for the copro ELISA-copro/Western Blot complex applied to feces collected from the environment. The objective was to compare the pros and cons of the two tests and to evaluate the human and the canine infection prevalence. The working area encompassed 7 Departments with systematic canine parasiticide activities (Program Area) and 4 Departments, not endemic, as Control Area. The arecoline test was applied to the dogs in assembled groups with the voluntary participation of their owners (not randomized sampling). Samples for the detection of coproantigens were obtained from sheep farms selected at random and analyzed by the complex copro-ELISA /Western Blot. Prevalence in man was determined by screening the school population (6 to 14 years old) by ultrasound, and by means of the compulsory notification of cases from the official system. Dogs (416) were tested with arecoline, 365 of which belonged to the Program Area. Of these 19 (5.2%) resulted positive, while none of 51 dogs from the Control Area were positive. Samples (748) of feces were tested to detect coproantigens, obtaining 37 positive samples within the Program Area and 4 within the Control Area. Farms (271) from the livestock estate unit were evaluated, out of which 236 belonged to the Program Area, gave 32 (13.6%) positive results, while 4 (11.4%) of 35 from the Control Area resulted positive. Sonography tests (7421) were done in the Program Area detecting 40 (0.5%) carriers, while in the Control Area, over 1732 tests, 9 (0.5%) resulted positive. The arecoline test provides information about the dog prevalence while the detection of coproantigens in feces collected from the environment allowed to enhance the quality of the information, and the identification of environments where specific control activities focusing on risk must be concentrated. Also the study allowed to recognize new transmission areas.
A Sediment Testing Reference Area Database for the San Francisco Deep Ocean Disposal Site (SF-DODS)
EPA established and maintains a SF-DODS reference area database of previously-collected sediment test data. Several sets of sediment test data have been successfully collected from the SF-DODS reference area.
3. TEST AREA 1115, OVERVIEW. AT RIGHT IS BUILDING 8647, ...
3. TEST AREA 1-115, OVERVIEW. AT RIGHT IS BUILDING 8647, TEST STAND 1-4. AT LEFT CENTER, IN THE MIDDLE DISTANCE, IS BUILDING 8668, INSTRUMENTATION AND CONTROL BUILDING FOR TEST AREA 1-115. Looking east from the deck of Test Stand 1-5. (PANORAMA 2/2) - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Leuhman Ridge near Highways 58 & 395, Boron, Kern County, CA
1. EAST ENTRANCE FROM LOADING AREA. CONCRETE TUNNEL TO TEST ...
1. EAST ENTRANCE FROM LOADING AREA. CONCRETE TUNNEL TO TEST STAND 1-3 IS AT RIGHT. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Instrumentation & Control Building, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA
8. AERIAL VIEW OF THE EAST TEST AREA DURING A ...
8. AERIAL VIEW OF THE EAST TEST AREA DURING A SATURN I STATIC TEST. THIS PHOTO WAS TAKEN IN 1960 JUST PRIOR TO THE CHANGE OVER OF LAND, FACILITIES AND MISSION FROM ARMY/MICOM (MISSILE COMMAND) TO NASA/MSFC (MARSHALL SPACE FLIGHT CENTER). MSFC PHOTO LAB. - Marshall Space Flight Center, East Test Area, Dodd Road, Huntsville, Madison County, AL
Performance Evaluation Test of the Rapid Area Preparation Tool (RAPTOR)
2008-12-01
the standard SETCO tires. A blast test of the new SETCO tire is scheduled for the spring of...Washington, DC 20301-2500 Performance Evaluation Test of the Rapid Area Preparation Tool (RAPTOR) December 2008 Prepared ...2008 to 00-00-2008 4. TITLE AND SUBTITLE Performance Evaluation Test of the Rapid Area Preparation Tool (RAPTOR) 5a. CONTRACT NUMBER 5b.
Operation of agricultural test fields for study of stressed crops by remote sensing
NASA Technical Reports Server (NTRS)
Toler, R. W.
1974-01-01
A test site for the study of winter wheat development and collection of ERTS data was established in September of 1973. The test site is a 10 mile square area located 12.5 miles west of Amarillo, Texas on Interstate Hwy. 40, in Randall and Potter counties. The center of the area is the Southwestern Great Plains Research Center at Bushland, Texas. Within the test area all wheat fields were identified by ground truth and designated irrigated or dryland. The fields in the test area other than wheat were identified as to pasture or the crop that was grown. A ground truth area of hard red winter wheat was established west of Hale Center, Texas. Maps showing the location of winter wheat fields in excess of 40 acres in size within a 10 mile radius were supplied NASA. Satellite data was collected for this test site (ERTS-1).
20. DECOMMISIONED HYDROGEN TANK IN FORMER LIQUID OXYGEN STORAGE AREA, ...
20. DECOMMISIONED HYDROGEN TANK IN FORMER LIQUID OXYGEN STORAGE AREA, BETWEEN TEST STAND 1-A AND INSTRUMENTATION AND CONTROL BUILDING. Looking northwest. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA
Code of Federal Regulations, 2013 CFR
2013-07-01
.... Naval Mine Warfare Test Station, or of U.S. Naval Air Station property. A person in the water or a... areas, U.S. Naval Air Test Center, Patuxent River, Md. 334.180 Section 334.180 Navigation and Navigable... REGULATIONS § 334.180 Patuxent River, Md.; restricted areas, U.S. Naval Air Test Center, Patuxent River, Md...
Code of Federal Regulations, 2014 CFR
2014-07-01
.... Naval Mine Warfare Test Station, or of U.S. Naval Air Station property. A person in the water or a... areas, U.S. Naval Air Test Center, Patuxent River, Md. 334.180 Section 334.180 Navigation and Navigable... REGULATIONS § 334.180 Patuxent River, Md.; restricted areas, U.S. Naval Air Test Center, Patuxent River, Md...
Code of Federal Regulations, 2012 CFR
2012-07-01
.... Naval Mine Warfare Test Station, or of U.S. Naval Air Station property. A person in the water or a... areas, U.S. Naval Air Test Center, Patuxent River, Md. 334.180 Section 334.180 Navigation and Navigable... REGULATIONS § 334.180 Patuxent River, Md.; restricted areas, U.S. Naval Air Test Center, Patuxent River, Md...
Code of Federal Regulations, 2011 CFR
2011-07-01
.... Naval Mine Warfare Test Station, or of U.S. Naval Air Station property. A person in the water or a... areas, U.S. Naval Air Test Center, Patuxent River, Md. 334.180 Section 334.180 Navigation and Navigable... REGULATIONS § 334.180 Patuxent River, Md.; restricted areas, U.S. Naval Air Test Center, Patuxent River, Md...
Code of Federal Regulations, 2010 CFR
2010-07-01
.... Naval Mine Warfare Test Station, or of U.S. Naval Air Station property. A person in the water or a... areas, U.S. Naval Air Test Center, Patuxent River, Md. 334.180 Section 334.180 Navigation and Navigable... REGULATIONS § 334.180 Patuxent River, Md.; restricted areas, U.S. Naval Air Test Center, Patuxent River, Md...
Electrode holder useful in a corrosion testing device
Murphy, R.J. Jr.; Jamison, D.E.
1986-08-19
The present invention is directed to an apparatus and method for holding one or more test electrodes of precisely known exposed surface area. The present invention is particularly useful in a device for determining the corrosion properties of the materials from which the test electrodes have been formed. The present invention relates to a device and method for holding the described electrodes wherein the exposed surface area of the electrodes is only infinitesimally decreased. Further, in the present invention the exposed, electrically conductive surface area of the contact devices is small relative to the test electrode surface area. The holder of the present invention conveniently comprises a device for contacting and engaging each test electrode at two point contacts infinitesimally small in relation to the exposed surface area of the electrodes. 4 figs.
Electrode holder useful in a corrosion testing device
Murphy, Jr., Robert J.; Jamison, Dale E.
1986-01-01
The present invention is directed to an apparatus and method for holding one or more test electrodes of precisely known exposed surface area. The present invention is particularly useful in a device for determining the corrosion properties of the materials from which the test electrodes have been formed. The present invention relates to a device and method for holding the described electrodes wherein the exposed surface area of the electrodes is only infinitesimally decreased. Further, in the present invention the exposed, electrically conductive surface area of the contact devices is small relative to the test electrode surface area. The holder of the present invention conveniently comprises a device for contacting and engaging each test electrode at two point contacts infinitesimally small in relation to the exposed surface area of the electrodes.
40 CFR 160.43 - Test system care facilities.
Code of Federal Regulations, 2010 CFR
2010-07-01
... testing facility shall have a number of animal rooms or other test system areas separate from those... GOOD LABORATORY PRACTICE STANDARDS Facilities § 160.43 Test system care facilities. (a) A testing facility shall have a sufficient number of animal rooms or other test system areas, as needed, to ensure...
40 CFR 160.43 - Test system care facilities.
Code of Federal Regulations, 2012 CFR
2012-07-01
... testing facility shall have a number of animal rooms or other test system areas separate from those... GOOD LABORATORY PRACTICE STANDARDS Facilities § 160.43 Test system care facilities. (a) A testing facility shall have a sufficient number of animal rooms or other test system areas, as needed, to ensure...
Kolor, Katherine; Chen, Zhuo; Grosse, Scott D; Rodriguez, Juan L; Green, Ridgely Fisk; Dotson, W David; Bowen, M Scott; Lynch, Julie A; Khoury, Muin J
2017-09-08
Genetic testing for breast cancer 1 (BRCA1) and breast cancer 2 (BRCA2) gene mutations can identify women at increased risk for breast and ovarian cancer. These testing results can be used to select preventive interventions and guide treatment. Differences between nonmetropolitan and metropolitan populations in rates of BRCA testing and receipt of preventive interventions after testing have not previously been examined. 2009-2014. Medical claims data from Truven Health Analytics MarketScan Commercial Claims and Encounters databases were used to estimate rates of BRCA testing and receipt of preventive interventions after BRCA testing among women aged 18-64 years with employer-sponsored health insurance in metropolitan and nonmetropolitan areas of the United States, both nationally and regionally. From 2009 to 2014, BRCA testing rates per 100,000 women aged 18-64 years with employer-sponsored health insurance increased 2.3 times (102.7 to 237.8) in metropolitan areas and 3.0 times (64.8 to 191.3) in nonmetropolitan areas. The relative difference in BRCA testing rates between metropolitan and nonmetropolitan areas decreased from 37% in 2009 (102.7 versus 64.8) to 20% in 2014 (237.8 versus 191.3). The relative difference in BRCA testing rates between metropolitan and nonmetropolitan areas decreased more over time in younger women than in older women and decreased in all regions except the West. Receipt of preventive services 90 days after BRCA testing in metropolitan versus nonmetropolitan areas throughout the period varied by service: the percentage of women who received a mastectomy was similar, the percentage of women who received magnetic resonance imaging of the breast was lower in nonmetropolitan areas (as low as 5.8% in 2014 to as high as 8.2% in 2011) than metropolitan areas (as low as 7.3% in 2014 to as high as 10.3% in 2011), and the percentage of women who received mammography was lower in nonmetropolitan areas in earlier years but was similar in later years. Possible explanations for the 47% decrease in the relative difference in BRCA testing rates over the study period include increased access to genetic services in nonmetropolitan areas and increased demand nationally as a result of publicity. The relative differences in metropolitan and nonmetropolitan BRCA testing rates were smaller among women at younger ages compared with older ages. Improved data sources and surveillance tools are needed to gather comprehensive data on BRCA testing in the United States, monitor adherence to evidence-based guidelines for BRCA testing, and assess receipt of preventive interventions for women with BRCA mutations. Programs can build on the recent decrease in geographic disparities in receipt of BRCA testing while simultaneously educating the public and health care providers about U.S. Preventive Services Task Force recommendations and other clinical guidelines for BRCA testing and counseling.
5. AERIAL PHOTO OF THE COMPONENTS TEST LABORATORY DURING THE ...
5. AERIAL PHOTO OF THE COMPONENTS TEST LABORATORY DURING THE CONSTRUCTION OF THE EAST TEST AREA. 1955, FRED ORDWAY COLLECTION, U.S. SPACE AND ROCKET CENTER, HUNTSVILLE, AL. - Marshall Space Flight Center, East Test Area, Components Test Laboratory, Huntsville, Madison County, AL
Continuous Improvement in Battery Testing at the NASA/JSC Energy System Test Area
NASA Technical Reports Server (NTRS)
Boyd, William; Cook, Joseph
2003-01-01
The Energy Systems Test Area (ESTA) at the Lyndon B. Johnson Space Center in Houston, Texas conducts development and qualification tests to fulfill Energy System Division responsibilities relevant to ASA programs and projects. EST A has historically called upon a variety of fluid, mechanical, electrical, environmental, and data system capabilities spread amongst five full-service facilities to test human and human supported spacecraft in the areas of propulsion systems, fluid systems, pyrotechnics, power generation, and power distribution and control systems. Improvements at ESTA are being made in full earnest of offering NASA project offices an option to choose a thorough test regime that is balanced with cost and schedule constraints. In order to continue testing of enabling power-related technologies utilized by the Energy System Division, an especially proactive effort has been made to increase the cost effectiveness and schedule responsiveness for battery testing. This paper describes the continuous improvement in battery testing at the Energy Systems Test Area being made through consolidation, streamlining, and standardization.
The SLS Stages Intertank Structural Test Assembly (STA) arrives at MSFC
2018-03-08
The SLS Stages Intertank Structural Test Assembly (STA) is rolling off the NASA Pegasus Barge at the MSFC Dock enroute to the MSFC 4619 Load Test Annex test facility for qualification testing via MSFC West Test Area. STA enters West Test Area from intersection of Dodd and Saturn roads. Onlookers take photos with Historic Dynamic Test Stand in background.
MBTA Green Line Tests - Riverside Line, December 1972 : Volume 1. Description.
DOT National Transportation Integrated Search
1973-09-01
The Urban Rail Supporting Technology Program emphasizes three major task areas; facilities development, technology development, and test program development. The test program development is composed of three sub-areas; vehicle testing, ways and struc...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Susan Stacy; Hollie K. Gilbert
2005-02-01
Test Area North (TAN) was a site of the Aircraft Nuclear Propulsion (ANP) Project of the U.S. Air Force and the Atomic Energy Commission. Its Cold War mission was to develop a turbojet bomber propelled by nuclear power. The project was part of an arms race. Test activities took place in five areas at TAN. The Assembly & Maintenance area was a shop and hot cell complex. Nuclear tests ran at the Initial Engine Test area. Low-power test reactors operated at a third cluster. The fourth area was for Administration. A Flight Engine Test facility (hangar) was built to housemore » the anticipated nuclear-powered aircraft. Experiments between 1955-1961 proved that a nuclear reactor could power a jet engine, but President John F. Kennedy canceled the project in March 1961. ANP facilities were adapted for new reactor projects, the most important of which were Loss of Fluid Tests (LOFT), part of an international safety program for commercial power reactors. Other projects included NASA's Systems for Nuclear Auxiliary Power and storage of Three Mile Island meltdown debris. National missions for TAN in reactor research and safety research have expired; demolition of historic TAN buildings is underway.« less
ERIC Educational Resources Information Center
Phelps, William R.
This report lists various factors of psychological testing which might be more relevant and appropriate for elementary school age children in such areas as Appalachia. The areas covered are group individual testing, individual intelligence testing, achievement testing, special clinical testing, social maturity, and personality evaluation…
MBTA Green Line Tests - Riverside Line, December 1972 : Volume 5. Gage Computer Printout.
DOT National Transportation Integrated Search
1973-01-01
The Urban Rail Supporting Technology Program emphasizes three major task areas; facilities development, technology development, and test program development. The test program development is composed of three sub-areas; vehicle testing, ways and struc...
MBTA Green Line Tests - Riverside Line, December 1972 : Volume 4. Westbound Track Profile.
DOT National Transportation Integrated Search
1973-01-01
The Urban Rail Supporting Technology Program emphasizes three major task areas; facilities development, technology development, and test program development. The test program development is composed of three sub-areas; vehicle testing, ways and struc...
MBTA Green Line Tests - Riverside Line, December 1972 : Volume 3. Eastbound Track Profile.
DOT National Transportation Integrated Search
1973-01-01
The Urban Rail Supporting Technology Program emphasizes three major task areas; facilities development, technology development, and test program development. The test program development is composed of three sub-areas; vehicle testing, ways and struc...
NASA Technical Reports Server (NTRS)
Lundebjerg, Kristen
2016-01-01
The Energy Test System's Area (ESTA) provides test capabilities and facilities to develop, evaluate or certify hardware in support of human spaceflight. The branch has a few different technical areas including pyrotechnics, batteries, electrical systems, power systems, propulsion and fluids. I will be mainly worked in the propulsion and fluids area. The tests/activities include testing the fluid and energy conversion systems that are required for the exploration and development of space. This group includes function and vibration tests, as well as thermal and vacuum tests. I was trained and certified as an ESTA test director in order to work on tests and sub tests with my mentor as well as the rest of the ESTA team. As a test director, I had the responsibility and authority for planning, developing, safety, execution and reporting on assigned test programs.
Addressable Inverter Matrix Tests Integrated-Circuit Wafer
NASA Technical Reports Server (NTRS)
Buehler, Martin G.
1988-01-01
Addressing elements indirectly through shift register reduces number of test probes. With aid of new technique, complex test structure on silicon wafer tested with relatively small number of test probes. Conserves silicon area by reduction of area devoted to pads. Allows thorough evaluation of test structure characteristics and of manufacturing process parameters. Test structure consists of shift register and matrix of inverter/transmission-gate cells connected to two-by-ten array of probe pads. Entire pattern contained in square area having only 1.6-millimeter sides. Shift register is conventional static CMOS device using inverters and transmission gates in master/slave D flip-flop configuration.
MBTA Green Line Tests - Riverside Line, December 1972 : Volume 2. Track Geometry Data Plots.
DOT National Transportation Integrated Search
1973-09-01
The Urban Rail Supporting Technology Program emphasizes three major task areas; facilities development, technology development, and test program development. The test program development is composed of three sub-areas; vehicle testing, ways and struc...
33 CFR 334.720 - Gulf of Mexico, south from Choctawhatchee Bay; Missile test area.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 33 Navigation and Navigable Waters 3 2014-07-01 2014-07-01 false Gulf of Mexico, south from Choctawhatchee Bay; Missile test area. 334.720 Section 334.720 Navigation and Navigable Waters CORPS OF ENGINEERS... Mexico, south from Choctawhatchee Bay; Missile test area. (a) The danger zone. The danger zone shall...
33 CFR 334.720 - Gulf of Mexico, south from Choctawhatchee Bay; Missile test area.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 33 Navigation and Navigable Waters 3 2012-07-01 2012-07-01 false Gulf of Mexico, south from Choctawhatchee Bay; Missile test area. 334.720 Section 334.720 Navigation and Navigable Waters CORPS OF ENGINEERS... Mexico, south from Choctawhatchee Bay; Missile test area. (a) The danger zone. The danger zone shall...
33 CFR 334.720 - Gulf of Mexico, south from Choctawhatchee Bay; Missile test area.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 33 Navigation and Navigable Waters 3 2013-07-01 2013-07-01 false Gulf of Mexico, south from Choctawhatchee Bay; Missile test area. 334.720 Section 334.720 Navigation and Navigable Waters CORPS OF ENGINEERS... Mexico, south from Choctawhatchee Bay; Missile test area. (a) The danger zone. The danger zone shall...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 3 2011-07-01 2011-07-01 false Gulf of Mexico, south from Choctawhatchee Bay; guided missiles test operations area, Headquarters Air Proving Ground Command, U.S. Air Force... Mexico, south from Choctawhatchee Bay; guided missiles test operations area, Headquarters Air Proving...
The objective of the geophysical surveys at the EPA Characterization Test Cell (CTC) area (Site) at Naval Base Ventura County, Port Hueneme, California is to locate geophysical anomalies indicative of metallic objects within the area of the cell. The goal was to provide backgroun...
33 CFR 334.260 - York River, Va.; naval restricted areas.
Code of Federal Regulations, 2014 CFR
2014-07-01
....; naval restricted areas. (a) The areas—(1) Naval mine service-testing area (prohibited). A rectangular...; and thence along the shore line to the point of beginning. (2) Naval mine service-testing area... case of emergency. Naval authorities are required to publish advance notice of mine-laying and/or...
33 CFR 334.260 - York River, Va.; naval restricted areas.
Code of Federal Regulations, 2013 CFR
2013-07-01
....; naval restricted areas. (a) The areas—(1) Naval mine service-testing area (prohibited). A rectangular...; and thence along the shore line to the point of beginning. (2) Naval mine service-testing area... case of emergency. Naval authorities are required to publish advance notice of mine-laying and/or...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-11
.... 334.260 York River, Va.; naval restricted areas. (a) The areas--(1) Naval mine service-testing area... thence along the shore line to the point of beginning. (2) Naval mine service-testing area (restricted... delay, except in case of emergency. Naval authorities are required to publish advance notice of mine...
Decline in Radiation Hardened Microcircuit Infrastructure
NASA Technical Reports Server (NTRS)
LaBel, Kenneth A.
2015-01-01
Two areas of radiation hardened microcircuit infrastructure will be discussed: 1) The availability and performance of radiation hardened microcircuits, and, and 2) The access to radiation test facilities primarily for proton single event effects (SEE) testing. Other areas not discussed, but are a concern include: The challenge for maintaining radiation effects tool access for assurance purposes, and, the access to radiation test facilities primarily for heavy ion single event effects (SEE) testing. Status and implications will be discussed for each area.
12 CFR 345.23 - Investment test.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 12 Banks and Banking 4 2010-01-01 2010-01-01 false Investment test. 345.23 Section 345.23 Banks... COMMUNITY REINVESTMENT Standards for Assessing Performance § 345.23 Investment test. (a) Scope of test. The investment test evaluates a bank's record of helping to meet the credit needs of its assessment area(s...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 12 Banks and Banking 3 2012-01-01 2012-01-01 false Service test. 228.24 Section 228.24 Banks and... REINVESTMENT (REGULATION BB) Standards for Assessing Performance § 228.24 Service test. (a) Scope of test. The service test evaluates a bank's record of helping to meet the credit needs of its assessment area(s) by...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 12 Banks and Banking 3 2010-01-01 2010-01-01 false Service test. 228.24 Section 228.24 Banks and... REINVESTMENT (REGULATION BB) Standards for Assessing Performance § 228.24 Service test. (a) Scope of test. The service test evaluates a bank's record of helping to meet the credit needs of its assessment area(s) by...
12 CFR 345.23 - Investment test.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 12 Banks and Banking 4 2011-01-01 2011-01-01 false Investment test. 345.23 Section 345.23 Banks... COMMUNITY REINVESTMENT Standards for Assessing Performance § 345.23 Investment test. (a) Scope of test. The investment test evaluates a bank's record of helping to meet the credit needs of its assessment area(s...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 12 Banks and Banking 3 2011-01-01 2011-01-01 false Service test. 228.24 Section 228.24 Banks and... REINVESTMENT (REGULATION BB) Standards for Assessing Performance § 228.24 Service test. (a) Scope of test. The service test evaluates a bank's record of helping to meet the credit needs of its assessment area(s) by...
12 CFR 345.23 - Investment test.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 12 Banks and Banking 5 2012-01-01 2012-01-01 false Investment test. 345.23 Section 345.23 Banks... COMMUNITY REINVESTMENT Standards for Assessing Performance § 345.23 Investment test. (a) Scope of test. The investment test evaluates a bank's record of helping to meet the credit needs of its assessment area(s...
2015-03-26
TEST AND EVALUATION OF ULTRASONIC ADDITIVE MANUFACTURING (UAM) FOR A LARGE AREA MAINTENANCE...States Government. AFIT-ENV-MS-15-M-158 TEST AND EVALUATION OF ULTRASONIC ADDITIVE MANUFACTURING FOR A LARGE AREA MAINTENANCE SHELTER...Civil Engineer (CE) operations. This research replicates a Large Area Maintenance Shelter (LAMS) baseplate design for ultrasonic additive
6. ENGINE TEST CELL BUILDING INTERIOR. CENTRAL OFFICE AREA ON ...
6. ENGINE TEST CELL BUILDING INTERIOR. CENTRAL OFFICE AREA ON BASEMENT LEVEL. LOOKING WEST. - Fairchild Air Force Base, Engine Test Cell Building, Near intersection of Arnold Street & George Avenue, Spokane, Spokane County, WA
Contreras, C E; Pance, A; Marcano, N; González, N; Bianco, N
1999-06-01
Malaria antibody detection is valuable in providing retrospective confirmation of an attack of malaria. Blood bank screening is another area were malaria serology is potentially useful. In the present study, we tested the presence of antibodies to Plasmodium falciparum in sera from blood bank donors of non-endemic and malaria-endemic areas of Venezuela. Sera from 1,000 blood donors were tested by an indirect immunofluorescent antibody (IFA) assay and an IgG-ELISA for the presence of malaria antibodies using a synchronized in vitro-cultured Venezuelan isolate of P. falciparum as the antigen source. A selected group of positive and negative sera (n = 100) was also tested by a dot-IgG-ELISA. Positive results (reciprocal titer > or = 40) were found in 0.8% and 3.8% of blood donors when tested by the IFA assay and in 0.8% and 2% (optical density > or = 0.2) when tested by the IgG-ELISA in Caracas (non-endemic area) and Bolivar City (endemic area), respectively. The presence of anti-malarial antibodies in some sera from non-endemic areas such as Caracas reflects the increased potential risk of post-transfusional malaria in those areas due to the mobility of the blood donors. The data obtained indicate the need to implement new blood donor policy in blood banks in developing areas. Our results also indicate that the IFA assay is the most reliable test to use in malaria serodiagnosis.
12 CFR 563e.22 - Lending test.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Lending test. 563e.22 Section 563e.22 Banks and... Assessing Performance § 563e.22 Lending test. (a) Scope of test. (1) The lending test evaluates a savings association's record of helping to meet the credit needs of its assessment area(s) through its lending...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 12 Banks and Banking 4 2010-01-01 2010-01-01 false Lending test. 345.22 Section 345.22 Banks and... REINVESTMENT Standards for Assessing Performance § 345.22 Lending test. (a) Scope of test. (1) The lending test evaluates a bank's record of helping to meet the credit needs of its assessment area(s) through its lending...
[Prediction of 137Cs accumulation in animal products in the territory of Semipalatinsk test site].
Spiridonov, S I; Gontarenko, I A; Mukusheva, M K; Fesenko, S V; Semioshkina, N A
2005-01-01
The paper describes mathematical models for 137Cs behavior in the organism of horses and sheep pasturing on the bording area to the testing area "Ground Zero" of the Semipalatinsk Test Site. The models are parameterized on the base of the data from an experiment with the breeds of animals now commonly encountered within the Semipalatinsk Test Site. The predictive calculations with the models devised have shown that 137Cs concentrations in milk of horses and sheep pasturingon the testing area to "Ground Zero" can exceed the adopted standards during a long period of time.
Effectiveness of urban stormwater control measures in a 100-acre test site
Kansas City, Missouri chose a test area (100 acres) and a control area (80 acres) to test the effectiveness of urban stormwater control (SCM) deployment in conjunction with the USEPA, University of Alabama, University of Missouri-Kansas City and TetraTech. Both the test and cont...
Booth, Amy R; Norman, Paul; Harris, Peter R; Goyder, Elizabeth
2015-09-01
The Theory of Planned Behavior was used to identify the key behavioural, normative and control beliefs underlying intentions to test regularly for chlamydia among young people living in socially and economically deprived areas - a high-risk group for infection. Participants (N = 278, 53% male; mean age 17 years) were recruited from a vocational college situated in an area in the most deprived national quintile (England). Participants completed measures of behavioural, normative and control beliefs, plus intention to test regularly for chlamydia. The behavioural, normative and control beliefs most strongly correlated with intentions to test regularly for chlamydia were beliefs about stopping the spread of infection, partners' behaviour and the availability of testing. These beliefs represent potential targets for interventions to increase chlamydia testing among young people living in deprived areas. © The Author(s) 2013.
Effect of area ratio on the performance of a 5.5:1 pressure ratio centrifugal impeller
NASA Technical Reports Server (NTRS)
Schumann, L. F.; Clark, D. A.; Wood, J. R.
1986-01-01
A centrifugal impeller which was initially designed for a pressure ratio of approximately 5.5 and a mass flow rate of 0.959 kg/sec was tested with a vaneless diffuser for a range of design point impeller area ratios from 2.322 to 2.945. The impeller area ratio was changed by successively cutting back the impeller exit axial width from an initial value of 7.57 mm to a final value of 5.97 mm. In all, four separate area ratios were tested. For each area ratio a series of impeller exit axial clearances was also tested. Test results are based on impeller exit surveys of total pressure, total temperature, and flow angle at a radius 1.115 times the impeller exit radius. Results of the tests at design speed, peak efficiency, and an exit tip clearance of 8 percent of exit blade height show that the impeller equivalent pressure recovery coefficient peaked at a design point area ratio of approximately 2.748 while the impeller aerodynamic efficiency peaked at a lower value of area ratio of approximately 2.55. The variation of impeller efficiency with clearance showed expected trends with a loss of approximately 0.4 points in impeller efficiency for each percent increase in exit axial tip clearance for all impellers tested.
The adolescent child health and illness profile. A population-based measure of health.
Starfield, B; Riley, A W; Green, B F; Ensminger, M E; Ryan, S A; Kelleher, K; Kim-Harris, S; Johnston, D; Vogel, K
1995-05-01
This study was designed to test the reliability and validity of an instrument to assess adolescent health status. Reliability and validity were examined by administration to adolescents (ages 11-17 years) in eight schools in two urban areas, one area in Appalachia, and one area in the rural South. Integrity of the domains and subdomains and construct validity were tested in all areas. Test/retest stability, criterion validity, and convergent and discriminant validity were tested in the two urban areas. Iterative testing has resulted in the final form of the CHIP-AE (Child Health and Illness Profile-Adolescent Edition) having 6 domains with 20 subdomains. The domains are Discomfort, Disorders, Satisfaction with Health, Achievement (of age-appropriate social roles), Risks, and Resilience. Tested aspects of reliability and validity have achieved acceptable levels for all retained subdomains. The CHIP-AE in its current form is suitable for assessing the health status of populations and subpopulations of adolescents. Evidence from test-retest stability analyses suggests that the CHIP-AE also can be used to assess changes occurring over time or in response to health services interventions targeted at groups of adolescents.
An Analysis of the Seismic Source Characteristics of Explosions in Low-Coupling Dry Porous Media
2011-09-29
Semipalatinsk Test Site (Shagan, Degelen and Konystan Testing Areas) and in Salt at the Former Soviet Azgir Test Site ...to be applicable to all underground nuclear explosions conducted in various hard rock media at the former Soviet Semipalatinsk test site , as well as...in Hard Rock at the Former Soviet Semipalatinsk Test Site (Shagan, Degelen and Konystan Testing Areas) and in Salt at the Former Soviet Azgir Test
1. BUILDING 8698, TEST STAND 13, WEST ELEVATION. NOTE TUNNEL ...
1. BUILDING 8698, TEST STAND 1-3, WEST ELEVATION. NOTE TUNNEL BETWEEN BLDG. 8668 AND TEST STAND 1-3. TEST AREA 1-120 IN THE MIDDLE DISTANCE, AND TEST AREA 1-125 ON THE HORIZON. Looking northeast from the roof of Building 8668, Instrumentation and Control Center. Note: Photograph CA-236-F-2 is an 8" x 10" enlargement from a 4" x 5" negative. This view is a photocopy of a recent resin coated print made from a print held at the Main Base History Office, Edwards Air Force Base, California. Photographer unknown. Date and file number unknown. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-3, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA
The Space Station Module Power Management and Distribution automation test bed
NASA Technical Reports Server (NTRS)
Lollar, Louis F.
1991-01-01
The Space Station Module Power Management And Distribution (SSM/PMAD) automation test bed project was begun at NASA/Marshall Space Flight Center (MSFC) in the mid-1980s to develop an autonomous, user-supportive power management and distribution test bed simulating the Space Station Freedom Hab/Lab modules. As the test bed has matured, many new technologies and projects have been added. The author focuses on three primary areas. The first area is the overall accomplishments of the test bed itself. These include a much-improved user interface, a more efficient expert system scheduler, improved communication among the three expert systems, and initial work on adding intermediate levels of autonomy. The second area is the addition of a more realistic power source to the SSM/PMAD test bed; this project is called the Large Autonomous Spacecraft Electrical Power System (LASEPS). The third area is the completion of a virtual link between the SSM/PMAD test bed at MSFC and the Autonomous Power Expert at Lewis Research Center.
Environmental Effects of Tungsten and Tantalum Alloys
1998-10-01
a groundwater well pumping at 400 gpm could potentially irrigate an area approximately 190 acres in size. Alloy metals from test area soils that...the Site. The home range of the beach mouse is similar to that of the deer mouse (Peromyscus leucopus), which has a home range of about 0.15 acres ...USEPA, 1993). The area of the C-64A test area is about 5.74 acres . The mice use and forage in grassland areas and would use much of this area. It is
7. BUILDING 604F, INTERIOR OF BULL PEN SHOWING TESTING STAND ...
7. BUILDING 604-F, INTERIOR OF BULL PEN SHOWING TESTING STAND AND HEAVY WOOD LINING ON CONCRETE WALLS. STEEL PLATE ABOVE TEST STAND DEFLECTS SHRAPNEL, SCREEN FURTHER HELPS TO CONTAIN PARTICLES. ONLY SMALL EXPLOSIVES WERE TESTED HERE (GRENADES, MINES, BOMB FUZES, ETC.). - Picatinny Arsenal, 600 Area, Test Areas District, State Route 15 near I-80, Dover, Morris County, NJ
9. "SANTA FE RAILWAY SPUR TO OPERATIONAL AREA, DIRECTORATE OF ...
9. "SANTA FE RAILWAY SPUR TO OPERATIONAL AREA, DIRECTORATE OF MISSILE CAPTIVE TEST, EDWARDS AFB"; Photo no. "11,381 57; G-AFFTC 18 SEPT 57". Test Area 1-115. Photo shows engine no. 712 pulling one car. The superstructure of Test Stand 1-4 is prominent in the background. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Leuhman Ridge near Highways 58 & 395, Boron, Kern County, CA
50 CFR Figure 7 to Part 679 - Location of Trawl Gear Test Areas in the GOA and the BSAI
Code of Federal Regulations, 2010 CFR
2010-10-01
... 50 Wildlife and Fisheries 9 2010-10-01 2010-10-01 false Location of Trawl Gear Test Areas in the GOA and the BSAI 7 Figure 7 to Part 679 Wildlife and Fisheries FISHERY CONSERVATION AND MANAGEMENT... EXCLUSIVE ECONOMIC ZONE OFF ALASKA Pt. 679, Fig. 7 Figure 7 to Part 679—Location of Trawl Gear Test Areas in...
Clifford, Susan; Hevey, David; Menezes, Gerard
2012-12-01
The aim of this study was to investigate the knowledge and attitudes of residents in the Castleisland area to radon. Castleisland in Co. Kerry was described as a high radon area following the discovery of a house in the area with radon levels 245 times that of the national reference level. Residents in this area were then asked to measure their homes for radon in the Castleisland radon survey. The uptake of this measurement was 17%. In order to investigate this response rate further, a questionnaire was designed and distributed to residents in the Castleisland area. This questionnaire measured the testing history of the participants, the reasons for testing/not testing, the factors important to them when considering having their home tested, radon knowledge and finally intentions to measure their home for radon. It was found that the main reason people do not test their home for radon is that they believe their home does not have a problem. Optimistic bias was thought to play a role here. The subjective norm component of the theory of planned behaviour was found to have a significant independent contribution in the variation in intentions to measure one's home for radon and this in turn could be targeted to increase uptake of radon measurement in the future.
Summary of Score Changes (in other Tests).
ERIC Educational Resources Information Center
Cleary, T. Anne; McCandless, Sam A.
Scholastic Aptitude Test (SAT) scores have declined during the last 14 years. Similar score declines have been observed in many different testing programs, many groups, and tested areas. The declines, while not large in any given year, have been consistent over time, area, and group. The period around 1965 is critical for the interpretation of…
Development and Validation of Diagnostic Economics Test for Secondary Schools
ERIC Educational Resources Information Center
Eleje, Lydia I.; Esomonu, Nkechi P. M.; Agu, Ngozi N.; Okoye, Romy O.; Obasi, Emma; Onah, Frederick E.
2016-01-01
A diagnostic test in economics to aid the teachers determine student's specific weak content areas was developed and validated. Five research questions guided the study. Preliminary validation was done by two experienced teachers in the content area of secondary economics and two experts in test construction. The pilot testing was conducted for…
Code of Federal Regulations, 2010 CFR
2010-07-01
... to Skiffes Creek and Mulberry Point, Va.; army training and small craft testing area. 334.280 Section... DEFENSE DANGER ZONE AND RESTRICTED AREA REGULATIONS § 334.280 James River between the entrance to Skiffes Creek and Mulberry Point, Va.; army training and small craft testing area. (a) The restricted area...
78 FR 63868 - Amendment of Restricted Area R-2515; Muroc Lake, CA
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-25
...-0802; Airspace Docket No. 13-AWP-7] RIN 2120-AA66 Amendment of Restricted Area R-2515; Muroc Lake, CA... using agency name for Restricted Area R-2515 Muroc Lake, CA, to read ``Commander, 412th Test Wing (412... using agency name for Restricted Area R-2515 Muroc Lake, CA, from ``Commander Air Force Flight Test...
3. SHOP AREA. Looking west into storage cage from near ...
3. SHOP AREA. Looking west into storage cage from near northeast corner of room. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A Terminal Room, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA
NASA Technical Reports Server (NTRS)
Taylor, R. E.; Hill, J. S.
1975-01-01
An airborne electromagnetic environment survey is described of five urban areas where terrestrially-generated radio-frequency interference was measured over the frequency range from 0.4 to 18.0 GHz. A chartered Cessna 402 aircraft contained necessary measurement test equipment, including the receiving antennas mounted beneath the fuselage. Urban areas including Washington, D.C.; Baltimore, MD; Philadelphia, PA; New York, NY; Chicago, ILL; and Palestine, TX were surveyed. A flight test plan and preliminary test results for the 0.4 to 1.4 GHz frequency range, are included; a final test report describes more detailed results.
Corrective action investigation plan for CAU Number 453: Area 9 Landfill, Tonopah Test Range
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
This Corrective Action Investigation Plan (CAIP) contains the environmental sample collection objectives and criteria for conducting site investigation activities at the Area 9 Landfill, Corrective Action Unit (CAU) 453/Corrective Action (CAS) 09-55-001-0952, which is located at the Tonopah Test Range (TTR). The TTR, included in the Nellis Air Force Range, is approximately 255 kilometers (140 miles) northwest of Las Vegas, Nevada. The Area 9 Landfill is located northwest of Area 9 on the TTR. The landfill cells associated with CAU 453 were excavated to receive waste generated from the daily operations conducted at Area 9 and from range cleanup whichmore » occurred after test activities.« less
Geology of the Chinese nuclear test site near Lop Nor, Xinjiang Uygur Autonomous Region, China
Matzko, J.R.
1994-01-01
The Chinese underground nuclear test site in the Kuruktag and Kyzyltag mountains of the Xinjiang Uygur Autonomous Region of northwest China, is the location of sixteen underground tests that occurred between 1969 and 1992. The largest test to date, conducted on 21 May 1992, had a reported yield of about one megaton. Geophysical properties of the rocks and a large-scale geologic map of part of the test area were published by the Chinese in 1986 and 1987 and are the first site-specific data available for this test site. In areas of low relief, underground nuclear testing has occurred below the water table, in shafts drilled vertically into dense, low porosity Paleozoic granitic and metasedimentary rocks. Additional testing in areas of more rugged terrain has occurred in horizontal tunnels, probably above the water table. At least one of these tunnels was driven into granite. The upper 50 m of the rock in the area of the vertical tests is weathered and fractured; these conditions have been shown to influence the magnitude of the disturbance of the land surface after a nuclear explosion. These descriptions suggest hard rock coupling at depth and a closer resemblance to the former Soviet test site in eastern Kazakhstan than to the U.S. test site in Nevada. ?? 1994.
ERIC Educational Resources Information Center
Plake, Barbara S., Ed.; Witt, Joseph C., Ed.
An introduction by Barbara S. Plake and Joseph C. Witt defines the task of this book as presenting nine conference papers discussing probable directions for the field of measurement and testing. In an effort to contribute to the improvement of test construction and test usage, areas of present concern and potentially important areas for the future…
6. "EXPERIMENTAL ROCKET ENGINE TEST STATION AT AFFTC." A low ...
6. "EXPERIMENTAL ROCKET ENGINE TEST STATION AT AFFTC." A low oblique aerial view of Test Area 1-115, looking south, showing Test Stand 1-3 at left, Instrumentation and Control building 8668 at center, and Test Stand 15 at right. The test area is under construction; no evidence of railroad line in photo. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Leuhman Ridge near Highways 58 & 395, Boron, Kern County, CA
5. METAL SHOP ROOM (AREA 108 ON PLAN CA236R36). Looking ...
5. METAL SHOP ROOM (AREA 108 ON PLAN CA-236-R-36). Looking northeast. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A Terminal Room, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA
Considerations for acoustic emission monitoring of spherical Kevlar/epoxy composite pressure vessels
NASA Technical Reports Server (NTRS)
Hamstad, M. A.; Patterson, R. G.
1977-01-01
We are continuing to research the applications of acoustic emission testing for predicting burst pressure of filament-wound Kevlar 49/epoxy pressure vessels. This study has focused on three specific areas. The first area involves development of an experimental technique and the proper instrumentation to measure the energy given off by the acoustic emission transducer per acoustic emission burst. The second area concerns the design of a test fixture in which to mount the composite vessel so that the acoustic emission transducers are held against the outer surface of the composite. Included in this study area is the calibration of the entire test setup including couplant, transducer, electronics, and the instrument measuring the energy per burst. In the third and final area of this study, we consider the number, location, and sensitivity of the acoustic emission transducers used for proof testing composite pressure vessels.
An investigation on impacts of scheduling configurations on Mississippi biology subject area testing
NASA Astrophysics Data System (ADS)
Marchette, Frances Lenora
The purpose of this mixed modal study was to compare the results of Biology Subject Area mean scores of students on a 4 x 4 block schedule, A/B block schedule, and traditional year-long schedule for 1A to 5A size schools. This study also reviewed the data to determine if minority or gender issues might influence the test results. Interviews with administrators and teachers were conducted about the type of schedule configuration they use and the influence that the schedule has on student academic performance on the Biology Subject Area Test. Additionally, this research further explored whether schedule configurations allow sufficient time for students to construct knowledge. This study is important to schools, teachers, and administrators because it can assist them in considering the impacts that different types of class schedules have on student performance and if ethnic or gender issues are influencing testing results. This study used the causal-comparative method for the quantitative portion of the study and constant comparative method for the qualitative portion to explore the relationship of school schedules on student academic achievement on the Mississippi Biology Subject Area Test. The aggregate means of selected student scores indicate that the Mississippi Biology Subject Area Test as a measure of student performance reveals no significant difference on student achievement for the three school schedule configurations. The data were adjusted for initial differences of gender, minority, and school size on the three schedule configurations. The results suggest that schools may employ various schedule configurations and expect student performance on the Mississippi Biology Subject Area Test to be unaffected. However, many areas of concern were identified in the interviews that might impact on school learning environments. These concerns relate to effective classroom management, the active involvement of students in learning, the adequacy of teacher education programs and the stress of testing on everyone involved in high-stakes testing.
Modelling of XCO₂ Surfaces Based on Flight Tests of TanSat Instruments.
Zhang, Li Li; Yue, Tian Xiang; Wilson, John P; Wang, Ding Yi; Zhao, Na; Liu, Yu; Liu, Dong Dong; Du, Zheng Ping; Wang, Yi Fu; Lin, Chao; Zheng, Yu Quan; Guo, Jian Hong
2016-11-01
The TanSat carbon satellite is to be launched at the end of 2016. In order to verify the performance of its instruments, a flight test of TanSat instruments was conducted in Jilin Province in September, 2015. The flight test area covered a total area of about 11,000 km² and the underlying surface cover included several lakes, forest land, grassland, wetland, farmland, a thermal power plant and numerous cities and villages. We modeled the column-average dry-air mole fraction of atmospheric carbon dioxide (XCO₂) surface based on flight test data which measured the near- and short-wave infrared (NIR) reflected solar radiation in the absorption bands at around 760 and 1610 nm. However, it is difficult to directly analyze the spatial distribution of XCO₂ in the flight area using the limited flight test data and the approximate surface of XCO₂, which was obtained by regression modeling, which is not very accurate either. We therefore used the high accuracy surface modeling (HASM) platform to fill the gaps where there is no information on XCO₂ in the flight test area, which takes the approximate surface of XCO₂ as its driving field and the XCO₂ observations retrieved from the flight test as its optimum control constraints. High accuracy surfaces of XCO₂ were constructed with HASM based on the flight's observations. The results showed that the mean XCO₂ in the flight test area is about 400 ppm and that XCO₂ over urban areas is much higher than in other places. Compared with OCO-2's XCO₂, the mean difference is 0.7 ppm and the standard deviation is 0.95 ppm. Therefore, the modelling of the XCO₂ surface based on the flight test of the TanSat instruments fell within an expected and acceptable range.
2009-05-01
rates are low, ranging from 0.014 to 2.2 liters per second (0.22 to 35 gallons per minute) (IT, 1997; Thordarson and Robinson, 1971). Most water...Area Ash Meadows Discharge Area Oasis Valley Discharge Area 29 fractured volcanic rocks (Winograd and Thordarson , 1975; Laczniak et al., 1996...Vicinity The current understanding of regional groundwater flow at the subject property and adjacent NTS is derived from work by Winograd and Thordarson
Individualizing the Teaching of Reading through Test Management Systems.
ERIC Educational Resources Information Center
Fry, Edward
Test management systems are suggested for individualizing the teaching of reading in the elementary classroom. Test management systems start with a list of objectives or specific goals which cover all or some major areas of the learning to read process. They then develop a large number of criterion referenced tests which match the skill areas at…
NASA Astrophysics Data System (ADS)
Petrie, G.; El Niweiri, A. E. H.
After reviewing the current status of topographic mapping in Sudan, the paper considers the possible applications of space inagery to the topographic mapping of the country at 1 : 100,000 scale. A comprehensive series of tests of the geometric accuracy and interpretability of six types of space imagery taken by the Landsat MSS, RBV and TM sensors, the MOMS scanner, the ESA Metric Camera and NASA's Large Format Camera have been conducted over a test area established in the Red Sea Hills area of Sudan supplemented by further interpretation tests carried out over the area of Khartoum and the Gezira. The results of these tests are given together with those from comparative tests carried out with other images acquired by the same sensors over test areas in developed countries (UK and USA). Further collateral information on topographic mapping at 1 : 100,000 scale from SPOT imagery has been provided by the Ordnance Survey based on its tests and experience in North Yemen. The paper concludes with an analysis of the possibilities of mapping the main (non-equatorial) area of Sudan at 1 : 100,000 scale based on the results of the extensive series of tests reported in the paper and elsewhere. Consideration is also given to the infrastructure required to support such a programme.
8. LOW OBLIQUE AERIAL VIEW OF TEST AREA 1115, SHOWING ...
8. LOW OBLIQUE AERIAL VIEW OF TEST AREA 1-115, SHOWING TEST STANDS 1-5, 1-4, AND 1-3 (LEFT TO RIGHT). - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Leuhman Ridge near Highways 58 & 395, Boron, Kern County, CA
Design and test of a prototype scale ejector wing
NASA Technical Reports Server (NTRS)
Mefferd, L. A.; Alden, R. E.; Bevilacqua, P. M.
1979-01-01
A two dimensional momentum integral analysis was used to examine the effect of changing inlet area ratio, diffuser area ratio, and the ratio of ejector length to width. A relatively wide range of these parameters was considered. It was found that for constant inlet area ratio the augmentation increases with the ejector length, and for constant length: width ratio the augmentation increases with inlet area ratio. Scale model tests were used to verify these trends and to examine th effect of aspect ratio. On the basis of these results, an ejector configuration was selected for fabrication and testing at a scale representative of an ejector wing aircraft. The test ejector was powered by a Pratt-Whitney F401 engine developing approximately 12,000 pounds of thrust. The results of preliminary tests indicate that the ejector develops a thrust augmentation ratio better than 1.65.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, Robert C.; King, Maureen L.; Beck, Colleen M.
This report presents the results of a National Historic Preservation Act Section 106 cultural resources inventory and historical evaluation of the 1957 Smoky atmospheric test location on the Nevada National Security Site (NNSS). The Desert Research Institute (DRI) was tasked to conduct a cultural resources study of the Smoky test area as a result of a proposed undertaking by the Department of Energy Environmental Management. This undertaking involves investigating Corrective Action Unit (CAU) 550 for potential contaminants of concern as delineated in a Corrective Action Investigation Plan. CAU 550 is an area that spatially overlaps portions of the Smoky testmore » location. Smoky, T-2c, was a 44 kt atmospheric nuclear test detonated at 5:30 am on August 31, 1957, on top of a 213.4 m (700 ft) 200 ton tower (T-2c) in Area 8 of the NNSS. Smoky was a weapons related test of the Plumbbob series (number 19) and part of the Department of Defense Exercise Desert Rock VII and VIII. The cultural resources effort involved the development of a historic context based on archival documents and engineering records, the inventory of the cultural resources in the Smoky test area and an associated military trench location in Areas 9 and 10, and an evaluation of the National Register eligibility of the cultural resources. The inventory of the Smoky test area resulted in the identification of structures, features, and artifacts related to the physical development of the test location and the post-test remains. The Smoky test area was designated historic district D104 and coincides with a historic archaeological site recorded as 26NY14794 and the military trenches designed for troop observation, site 26NY14795. Sites 26NY14794 and 26NY14795 are spatially discrete with the trenches located 4.3 km (2.7 mi) southeast of the Smoky ground zero. As a result, historic district D104 is discontiguous and in total it covers 151.4 hectares (374 acres). The Smoky test location, recorded as historic district D104 and historic sites 26NY14794 and 26NY14795, is the best preserved post-shot atmospheric nuclear tower test at the NNSS and possibly in the world. It is of local, national, and international importance due to nuclear testing’s pivotal role in the Cold War between the United States and the former Soviet Union. The district and sites are linked to the historic theme of atmospheric nuclear testing. D104 retains aspects of the engineering plan and design for the Smoky tower, instrument stations used to measure test effects, German and French personnel shelters, and military trenches. A total of 33 structures contribute to the significance of D104. Artifacts and features provide significant post-test information. Historic district D104 (discontiguous) and historic site 26NY14794 (the Smoky test area) are eligible for listing on the NRHP under Criteria A, B, C, and D. The historic site 26NY14795 (the Smoky military trenches) is eligible for listing under Criteria A, C, and D. Several items have been identified for removal by the CAU 550 investigation. However, none of them is associated with the Smoky atmospheric test, but with later activities in the area. The military trenches are not part of CAU 550 and no actions are planned there. A proposed closure of the Smoky test area with restrictions will limit access and contribute to the preservation of the cultural resources. It is recommended that the Smoky historic district and sites be included in the NNSS cultural resources monitoring program.« less
Integrating borehole logs and aquifer tests in aquifer characterization
Paillet, Frederick L.; Reese, R.S.
2000-01-01
Integration of lithologic logs, geophysical logs, and hydraulic tests is critical in characterizing heterogeneous aquifers. Typically only a limited number of aquifer tests can be performed, and these need to be designed to provide hydraulic properties for the principle aquifers in the system. This study describes the integration of logs and aquifer tests in the development of a hydrostratigraphic model for the surficial aquifer system in and around Big Cypress National Preserve in eastern Collier County, Florida. Borehole flowmeter tests provide qualitative permeability profiles in most of 26 boreholes drilled in the Study area. Flow logs indicate the depth of transmissive units, which are correlated across the study area. Comparison to published studies in adjacent areas indicates that the main limestone aquifer of the 000000Tamiami Formation in the study area corresponds with the gray limestone aquifer in western Dade County and the water table and lower Tamiami Aquifer in western Collier County. Four strategically located, multiwell aquifer tests are used to quantify the qualitative permeability profiles provided by the flowmeter log analysis. The hydrostratigraphic model based on these results defines the main aquifer in the central part of the study area as unconfined to semiconfined with a transmissivity as high as 30,000 m2/day. The aquifer decreases in transmissivity to less than 10,000 m2/day in some parts of western Collier County, and becomes confined to the east and northeast of the study area, where transmissivity decreases to below 5000 m2/day.Integration of lithologic logs, geophysical logs, and hydraulic tests is critical in characterizing heterogeneous aquifers. Typically only a limited number of aquifer tests can be performed, and these need to be designed to provide hydraulic properties for the principle aquifers in the system. This study describes the integration of logs and aquifer tests in the development of a hydrostratigraphic model for the surficial aquifer system in and around Big Cypress National Preserve in eastern Collier County, Florida. Borehole flowmeter tests provide qualitative permeability profiles in most of 26 boreholes drilled in the study area. Flow logs indicate the depth of transmissive units, which are correlated across the study area. Comparison to published studies in adjacent areas indicates that the main limestone aquifer of the Tamiami Formation in the study area corresponds with the gray limestone aquifer in western Dade County and the water table and lower Tamiami Aquifer in western Collier County. Four strategically located, multiwell aquifer tests are used to quantify the qualitative permeability profiles provided by the flowmeter log analysis. The hydrostratigraphic model based on these results defines the main aquifer in the central part of the study area as unconfined to semiconfined with a transmissivity as high as 30,000 m2/day. The aquifer decreases in transmissivity to less than 10,000 m2/day in some parts of western Collier County, and becomes confined to the east and northeast of the study area, where transmissivity decreases to below 5000 m2/day.
Operation BUSTER. Project 2.2. Thermal and Blast Effects on Idealized Forest Fuels
1952-04-29
outside the test area . Naturally occurring fuels at the test site mm brush, grass clumps, and Joshua bark — ware studied before the tests and...oharrad« Conclusions based on results and observations from Operation BDSBRt 1. Under fire weather oonditionsi/ in a forest area , atomic ex...following atomic explosions over forest areas * 5* Bomb-induced conreotion does not produce surface winds follow« lag blastHTind effects and need not be
Dimova, Violeta; Oertel, Bruno G; Lötsch, Jörn
2017-01-01
Skin sensitivity to sensory stimuli varies among different body areas. A standardized clinical quantitative sensory testing (QST) battery, established for the diagnosis of neuropathic pain, was used to assess whether the magnitude of differences between test sites reaches clinical significance. Ten different sensory QST measures derived from thermal and mechanical stimuli were obtained from 21 healthy volunteers (10 men) and used to create somatosensory profiles bilateral from the dorsum of the hands (the standard area for the assessment of normative values for the upper extremities as proposed by the German Research Network on Neuropathic Pain) and bilateral at volar forearms as a neighboring nonstandard area. The parameters obtained were statistically compared between test sites. Three of the 10 QST parameters differed significantly with respect to the "body area," that is, warmth detection, thermal sensory limen, and mechanical pain thresholds. After z-transformation and interpretation according to the QST battery's standard instructions, 22 abnormal values were obtained at the hand. Applying the same procedure to parameters assessed at the nonstandard site forearm, that is, z-transforming them to the reference values for the hand, 24 measurements values emerged as abnormal, which was not significantly different compared with the hand (P=0.4185). Sensory differences between neighboring body areas are statistically significant, reproducing prior knowledge. This has to be considered in scientific assessments where a small variation of the tested body areas may not be an option. However, the magnitude of these differences was below the difference in sensory parameters that is judged as abnormal, indicating a robustness of the QST instrument against protocol deviations with respect to the test area when using the method of comparison with a 95 % confidence interval of a reference dataset.
Studies on geotechnical properties of subsoil in south east coastal region of India
NASA Astrophysics Data System (ADS)
Dutta, Susom; Barik, D. K.
2017-11-01
Soil testing and analysis has become essential before commencement of any activity or process on soil i.e. residential construction, road construction etc. It is the most important work particularly in coastal area as these areas are more vulnerable to the natural disastrous like tsunami and cyclone. In India, there is lack of facility to collect and analyse the soil from the field. Hence, to study the various characteristics of the coastal region sub soil, Old Mahabalipuram area, which is the South East region of India has been chosen in this study. The aim of this study is to collect and analyse the soil sample from various localities of the Old Mahabalipuram area. The analysed soil data will be helpful for the people who are working in the field of Geotechnical in coastal region of India to make decision. The soil sample collected from different boreholes have undergone various field and laboratory tests like Pressuremeter Test, Field Permeability Test, Electrical Resistivity Test, Standard Penetration Test, Shear Test, Atterberg Limits etc. are performed including rock tests to know the geotechnical properties of the soil samples for each and every stratum
3. "LAUNCH SILOS; AREA PAVING AND GRADING PLAN." Specifications No. ...
3. "LAUNCH SILOS; AREA PAVING AND GRADING PLAN." Specifications No. ENG-04-353-59-73; Drawing No. 5841C-11; D.O. SERIES AW-1525/17; Stamped: RECORD DRAWING AS CONSTRUCTED. Below stamp: Contract No. 6601, Date 18 Sep 59. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Missile Silo Type, Test Area 1-100, northeast end of Test Area 1-100 Road, Boron, Kern County, CA
Cai, Zhen-bing; Zhao, Lei; Zhang, Xu; Yue, Wen; Zhu, Min-hao
2016-01-01
A ball-on-plate wear test was employed to investigate the effectiveness of graphene (GP) nanoparticles dispersed in a synthetic-oil-based lubricant in reducing wear. The effect by area ratio of elliptically shaped dimple textures and elevated temperatures were also explored. Pure PAO4 based oil and a mixture of this oil with 0.01 wt% GP were compared as lubricants. At pit area ratio of 5%, GP-base oil effectively reduced friction and wear, especially at 60 and 100°C. Under pure PAO4 oil lubrication, the untextured surfaces gained low friction coefficients (COFs) and wear rates under 60 and 100°C. With increasing laser—texture area ratio, the COF and wear rate decreased at 25 and 150°C but increased at 60 and 100°C. Under the GP-based oil lubrication, the textured surface with 5% area ratio achieved the lowest COF among those of the area ratios tested at all test temperatures. Meanwhile, the textured surface with 20% area ratio obtained the highest COF among those of the area ratios. With the joint action of GP and texture, the textured surface with 10% area ratio exhibited the best anti-wear performance among all of the textured surfaces at all test temperatures. PMID:27054762
Comparison of model and flight test data for an augmented jet flap STOL research aircraft
NASA Technical Reports Server (NTRS)
Cook, W. L.; Whittley, D. C.
1975-01-01
Aerodynamic design data for the Augmented Jet Flap STOL Research Aircraft or commonly known as the Augmentor-Wing Jet-STOL Research Aircraft was based on results of tests carried out on a large scale research model in the NASA Ames 40- by 80-Foot Wind Tunnel. Since the model differs in some respects from the aircraft, precise correlation between tunnel and flight test is not expected, however the major areas of confidence derived from the wind tunnel tests are delineated, and for the most part, tunnel results compare favorably with flight experience. In some areas the model tests were known to be nonrepresentative so that a degree of uncertainty remained: these areas of greater uncertainty are identified, and discussed in the light of subsequent flight tests.
2. TEST AREA 1115, A VIEW TO THE SOUTHEAST FROM ...
2. TEST AREA 1-115, A VIEW TO THE SOUTHEAST FROM THE DECK OF TEST STAND 1-5. AT RIGHT IS BUILDING 8642, MACHINE SHOP FOR TEST STAND 1-5. AT LEFT IS BUILDING 8649, AND PART OF BUILDING 8647, TEST STAND 1-4, IS VISIBLE TO LEFT OF BLDG. 8649. (PANORAMA 1/2). - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Leuhman Ridge near Highways 58 & 395, Boron, Kern County, CA
40 CFR 761.310 - Collecting the sample.
Code of Federal Regulations, 2013 CFR
2013-07-01
... standard wipe test as defined in § 761.123 to sample one 10 centimeter by 10 centimeter square (100 cm2) area to represent surface area PCB concentrations of each square meter or fraction of a square meter of... wipe test, only sample the entire area, rather than 10 centimeter by 10 centimeter squares. ...
40 CFR 761.310 - Collecting the sample.
Code of Federal Regulations, 2011 CFR
2011-07-01
... standard wipe test as defined in § 761.123 to sample one 10 centimeter by 10 centimeter square (100 cm2) area to represent surface area PCB concentrations of each square meter or fraction of a square meter of... wipe test, only sample the entire area, rather than 10 centimeter by 10 centimeter squares. ...
40 CFR 761.310 - Collecting the sample.
Code of Federal Regulations, 2014 CFR
2014-07-01
... standard wipe test as defined in § 761.123 to sample one 10 centimeter by 10 centimeter square (100 cm2) area to represent surface area PCB concentrations of each square meter or fraction of a square meter of... wipe test, only sample the entire area, rather than 10 centimeter by 10 centimeter squares. ...
40 CFR 761.310 - Collecting the sample.
Code of Federal Regulations, 2012 CFR
2012-07-01
... standard wipe test as defined in § 761.123 to sample one 10 centimeter by 10 centimeter square (100 cm2) area to represent surface area PCB concentrations of each square meter or fraction of a square meter of... wipe test, only sample the entire area, rather than 10 centimeter by 10 centimeter squares. ...
40 CFR 761.310 - Collecting the sample.
Code of Federal Regulations, 2010 CFR
2010-07-01
... standard wipe test as defined in § 761.123 to sample one 10 centimeter by 10 centimeter square (100 cm2) area to represent surface area PCB concentrations of each square meter or fraction of a square meter of... wipe test, only sample the entire area, rather than 10 centimeter by 10 centimeter squares. ...
NASA Technical Reports Server (NTRS)
Kozlowski, H.; Packman, A. B.
1978-01-01
Acoustic data from tests of the 0.75 area ratio coannular nozzle with ejector and the 1.2 area ratio coannular are presented in tables. Aerodynamic data acquired for the four test configurations are included.
What Does Neuroscience and Cognitive Psychology Tell Us about Multiple Intelligence
ERIC Educational Resources Information Center
Bauer, Richard H.
2009-01-01
Studies that have used noninvasive brain imaging techniques to record neocortical activity while individuals were performing cognitive intelligence tests (traditional intelligence) and social intelligence tests were reviewed. In cognitive intelligence tests 16 neocortical areas were active, whereas in social intelligence 10 areas were active.…
Underground Test Area Subproject Project Management Plan, Revision 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-06-03
This Project Management Plan (PMP) describes the manner in which the US Department of Energy Nevada Operations Office (DOE/NV) will manage the Underground Test Area (UGTA) Subproject at the Nevada Test Site (NTS). It provides the basic guidance for implementation and the organizational structure for meeting the UGTA objectives.
Teacher Testing and the Pacific Areas.
ERIC Educational Resources Information Center
Adachi, Mitsuo
The purpose of this paper was to ascertain in some measure the direction teacher testing may take in the Pacific Area states other than Guam and Hawaii. Guam and Hawaii have installed teacher testing programs and have clearly established certification requirements that make it mandatory for teacher applicants to have baccalaureates. The other…
The Long Exercise Test in Periodic Paralysis: A Bayesian Analysis.
Simmons, Daniel B; Lanning, Julie; Cleland, James C; Puwanant, Araya; Twydell, Paul T; Griggs, Robert C; Tawil, Rabi; Logigian, Eric L
2018-05-12
The long exercise test (LET) is used to assess the diagnosis of periodic paralysis (PP), but LET methodology and normal "cut-off" values vary. To determine optimal LET methodology and cut-offs, we reviewed LET data (abductor digiti minimi (ADM) motor response amplitude, area) from 55 PP patients (32 genetically definite) and 125 controls. Receiver operating characteristic (ROC) curves were constructed and area-under-the-curve (AUC) calculated to compare 1) peak-to-nadir versus baseline-to-nadir methodologies, and 2) amplitude versus area decrements. Using Bayesian principles, optimal "cut-off" decrements that achieved 95% post-test probability of PP were calculated for various pre-test probabilities (PreTPs). AUC was highest for peak-to-nadir methodology and equal for amplitude and area decrements. For PreTP ≤50%, optimal decrement cut-offs (peak-to-nadir) were >40% (amplitude) or >50% (area). For confirmation of PP, our data endorse the diagnostic utility of peak-to-nadir LET methodology using 40% amplitude or 50% area decrement cut-offs for PreTPs ≤50%. This article is protected by copyright. All rights reserved. © 2018 Wiley Periodicals, Inc.
2015-12-01
strive in multiple warfare areas. This research benefits not only the Navy, through enhancement of offensive warfighting by testing the next...multiple warfare areas. This research benefits not only the Navy, through enhancement of offensive warfighting by testing the next generation of...produce and definitely worth the research and testing to be a positive asset for the Navy. It not only can stay on station for an exponential amount of
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gruendell, B.D.; Barrows, E.S.; Borde, A.B.
1997-01-01
The objective of the bioassay reevaluation of the Hackensack River Federal Project was to reperform toxicity testing on proposed dredged material with current ammonia reduction protocols. Hackensack River was one of four waterways sampled and evaluated for dredging and disposal in April 1993. Sediment samples were re-collected from the Hackensack River Project area in August 1995. Tests and analyses were conducted according to the manual developed by the USACE and the U.S. Environmental Protection Agency (EPA), Evaluation of Dredged Material Proposed for Ocean Disposal (Testing Manual), commonly referred to as the {open_quotes}Green Book,{close_quotes} and the regional manual developed by themore » USACE-NYD and EPA Region II, Guidance for Performing Tests on Dredged Material to be Disposed of in Ocean Waters. The reevaluation of proposed dredged material from the Hackensack River project area consisted of benthic acute toxicity tests. Thirty-three individual sediment core samples were collected from the Hackensack River project area. Three composite sediments, representing each reach of the area proposed for dredging, were used in benthic acute toxicity testing. Benthic acute toxicity tests were performed with the amphipod Ampelisca abdita and the mysid Mysidopsis bahia. The amphipod and mysid benthic toxicity test procedures followed EPA guidance for reduction of total ammonia concentrations in test systems prior to test initiation. Statistically significant acute toxicity was found in all three Hackensack River composites in the static renewal tests with A. abdita, but not in the static tests with M. bahia. Statistically significant acute toxicity and a greater than 20% increase in mortality over the reference sediment was found in the static renewal tests with A. abdita. Statistically significant mortality 10% over reference sediment was observed in the M. bahia static tests. 5 refs., 2 figs., 2 tabs.« less
Evaluation of dredged material proposed for ocean disposal from Arthur Kill Project Area, New York
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gruendell, B.D.; Barrows, E.S.; Borde, A.B.
1997-01-01
The objective of the bioassay reevaluation of Arthur Kill Federal Project was to reperform toxicity testing on proposed dredged material following current ammonia reduction protocols. Arthur Kill was one of four waterways sampled and evaluated for dredging and disposal in April 1993. Sediment samples were recollected from the Arthur Kill Project areas in August 1995. Tests and analyses were conducted according to the manual developed by the USACE and the U.S. Environmental Protection Agency (EPA), Evaluation of Dredged Material Proposed for Ocean Disposal (Testing Manual), commonly referred to as the {open_quotes}Green Book,{close_quotes} and the regional manual developed by the USACE-NYDmore » and EPA Region II, Guidance for Performing Tests on Dredged Material to be Disposed of in Ocean Waters. The reevaluation of proposed dredged material from the Arthur Kill project areas consisted of benthic acute toxicity tests. Thirty-three individual sediment core samples were collected from the Arthur Kill project area. Three composite sediments, representing each reach of the area proposed for dredging, was used in benthic acute toxicity testing. Benthic acute toxicity tests were performed with the amphipod Ampelisca abdita and the mysid Mysidopsis bahia. The amphipod and mysid benthic toxicity test procedures followed EPA guidance for reduction of total ammonia concentrations in test systems prior to test initiation. Statistically significant acute toxicity was found in all Arthur Kill composites in the static renewal tests with A. abdita, but not in the static tests with M. bahia. Statistically significant acute toxicity and a greater than 20% increase in mortality over the reference sediment was found in the static renewal tests with A. abdita. M. bahia did not show statistically significant acute toxicity or a greater than 10% increase in mortality over reference sediment in static tests. 5 refs., 2 figs., 2 tabs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1992-11-24
This proposed action provides the Department of Energy (DOE) authorization to the US Army to conduct a testing program using Depleted Uranium (DU) in Area 25 at the Nevada Test Site (NTS). The US Army Ballistic Research Laboratory (BRL) would be the managing agency for the program. The proposed action site would utilize existing facilities, and human activity would be confined to areas identified as having no tortoise activity. Two classifications of tests would be conducted under the testing program: (1) open-air tests, and (2) X-Tunnel tests. A series of investigative tests would be conducted to obtain information on DUmore » use under the conditions of each classification. The open-air tests would include DU ammunition hazard classification and combat systems activity tests. Upon completion of each test or series of tests, the area would be decontaminated to meet requirements of DOE Order 5400.5, Radiation Protection of the Public and Environment. All contaminated materials would be decontaminated or disposed of as radioactive waste in an approved low-level Radioactive Waste Management Site (RWMS) by personnel trained specifically for this purpose.« less
ERIC Educational Resources Information Center
Keosybounheuang, Sunnin Bree
2017-01-01
High stakes testing is an increasingly powerful force in education with curricular decisions as one of the many factors influenced by this trend. A large number of districts and school leaders feel an increase in curriculum time for tested areas is the answer to America's academic shortcomings. The increase in instructional time for tested areas,…
Looking North into Lab Metallurgy Testing Area and Enrichment Motor ...
Looking North into Lab Metallurgy Testing Area and Enrichment Motor within Recycle Recovery Building - Hematite Fuel Fabrication Facility, Recycle Recovery Building, 3300 State Road P, Festus, Jefferson County, MO
Impact of Exposure to Pressure of 50 MPa on the Specific Surface Area of Clay
NASA Astrophysics Data System (ADS)
Koszela-Marek, Ewa
2017-12-01
The paper presents results of laboratory tests conducted to determine the impact of pressure of 50 MPa on specific surface area of clay. These tests were carried out in an original, high-pressure test stand. The specific surface area of clay extracted directly from an open pit mine was compared with the specific surface area of the same clay subjected to the pressure of 50 MPa in a high-pressure chamber. The study found that the specific surface area of the clay subjected to the pressure of 50 MPa increased distinctly by over 35 %. The increase in specific surface can be a result of changes in the microstructure of clay particles and microstructural alteration in the soil skeleton, caused by the pressure.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Gulf of Mexico, south from... Mexico, south from Choctawhatchee Bay; guided missiles test operations area, Headquarters Air Proving... Mexico south from Choctawhatchee Bay within an area described as follows: Beginning at a point five...
12 CFR 563e.25 - Community development test for wholesale or limited purpose savings associations.
Code of Federal Regulations, 2010 CFR
2010-01-01
...). (e) Benefit to assessment area(s)—(1) Benefit inside assessment area(s). The OTS considers all... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Community development test for wholesale or limited purpose savings associations. 563e.25 Section 563e.25 Banks and Banking OFFICE OF THRIFT...
Code of Federal Regulations, 2012 CFR
2012-07-01
....; experimental test area, U.S. Navy Marine Engineering Laboratory. 334.150 Section 334.150 Navigation and... Marine Engineering Laboratory. (a) The restricted area. The waters of Severn River shoreward of a line beginning at the southeasternmost corner of the U.S. Navy Marine Engineering Laboratory sea wall and running...
Code of Federal Regulations, 2011 CFR
2011-07-01
....; experimental test area, U.S. Navy Marine Engineering Laboratory. 334.150 Section 334.150 Navigation and... Marine Engineering Laboratory. (a) The restricted area. The waters of Severn River shoreward of a line beginning at the southeasternmost corner of the U.S. Navy Marine Engineering Laboratory sea wall and running...
Code of Federal Regulations, 2014 CFR
2014-07-01
....; experimental test area, U.S. Navy Marine Engineering Laboratory. 334.150 Section 334.150 Navigation and... Marine Engineering Laboratory. (a) The restricted area. The waters of Severn River shoreward of a line beginning at the southeasternmost corner of the U.S. Navy Marine Engineering Laboratory sea wall and running...
Code of Federal Regulations, 2013 CFR
2013-07-01
....; experimental test area, U.S. Navy Marine Engineering Laboratory. 334.150 Section 334.150 Navigation and... Marine Engineering Laboratory. (a) The restricted area. The waters of Severn River shoreward of a line beginning at the southeasternmost corner of the U.S. Navy Marine Engineering Laboratory sea wall and running...
Code of Federal Regulations, 2010 CFR
2010-07-01
....; experimental test area, U.S. Navy Marine Engineering Laboratory. 334.150 Section 334.150 Navigation and... Marine Engineering Laboratory. (a) The restricted area. The waters of Severn River shoreward of a line beginning at the southeasternmost corner of the U.S. Navy Marine Engineering Laboratory sea wall and running...
REACTOR SERVICE BUILDING, TRA635. CROWDED MOCKUP AREA. CAMERA FACES EAST. ...
REACTOR SERVICE BUILDING, TRA-635. CROWDED MOCK-UP AREA. CAMERA FACES EAST. PHOTOGRAPHER'S NOTE SAYS "PICTURE REQUESTED BY IDO IN SUPPORT OF FY '58 BUILDING PROJECTS." INL NEGATIVE NO. 56-3025. R.G. Larsen, Photographer, 9/13/1956 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-28
... bubbles at molecular, cellular and organ function levels, to comparative studies relating the presence... environmental effects associated with the Q-20 test activities proposed for the Q-20 Study Area (see below for detailed description of the Study Area), which includes non-territorial waters of Military Warning Area 151...
21 CFR 352.72 - General testing procedures.
Code of Federal Regulations, 2014 CFR
2014-04-01
..., suntan, scars, active dermal lesions, and uneven skin tones on the areas of the back to be tested. The... immediate responses are noted, each subject shall shield the exposed area from further UV radiation for the... noncompliant (e.g., subject withdraws from the test due to illness or work conflicts, subject does not shield...
21 CFR 352.72 - General testing procedures.
Code of Federal Regulations, 2011 CFR
2011-04-01
..., suntan, scars, active dermal lesions, and uneven skin tones on the areas of the back to be tested. The... immediate responses are noted, each subject shall shield the exposed area from further UV radiation for the... noncompliant (e.g., subject withdraws from the test due to illness or work conflicts, subject does not shield...
21 CFR 352.72 - General testing procedures.
Code of Federal Regulations, 2012 CFR
2012-04-01
..., suntan, scars, active dermal lesions, and uneven skin tones on the areas of the back to be tested. The... immediate responses are noted, each subject shall shield the exposed area from further UV radiation for the... noncompliant (e.g., subject withdraws from the test due to illness or work conflicts, subject does not shield...
21 CFR 352.72 - General testing procedures.
Code of Federal Regulations, 2013 CFR
2013-04-01
..., suntan, scars, active dermal lesions, and uneven skin tones on the areas of the back to be tested. The... immediate responses are noted, each subject shall shield the exposed area from further UV radiation for the... noncompliant (e.g., subject withdraws from the test due to illness or work conflicts, subject does not shield...
5. WEST SIDE, ALSO SHOWING INSTRUMENTATION AND CONTROL BUILDING (BLDG. ...
5. WEST SIDE, ALSO SHOWING INSTRUMENTATION AND CONTROL BUILDING (BLDG. 8668) IN MIDDLE DISTANCE AT LEFT, AND TEST AREAS 1-120 AND 1-125 BEYOND. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-4, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA
2012-01-01
Background The World Health Organization recommends parasitological confirmation of all malaria cases. Tanzania is implementing a phased rollout of malaria rapid diagnostic tests (RDTs) for routine use in all levels of care as one strategy to increase parasitological confirmation of malaria diagnosis. This study was carried out to evaluated artemisinin combination therapy (ACT) prescribing patterns in febrile patients with and without uncomplicated malaria in one pre-RDT implementation and one post-RDT implementation area. Methods A cross-sectional health facility surveys was conducted during high and low malaria transmission seasons in 2010 in both areas. Clinical information and a reference blood film on all patients presenting for an initial illness consultation were collected. Malaria was defined as a history of fever in the past 48 h and microscopically confirmed parasitaemia. Routine diagnostic testing was defined as RDT or microscopy ordered by the health worker and performed at the health facility as part of the health worker-patient consultation. Correct diagnostic testing was defined as febrile patient tested with RDT or microscopy. Over-testing was defined as a non-febrile patient tested with RDT or microscopy. Correct treatment was defined as patient with malaria prescribed ACT. Over-treatment was defined as patient without malaria prescribed ACT. Results A total of 1,247 febrile patients (627 from pre-implementation area and 620 from post-implementation area) were included in the analysis. In the post-RDT implementation area, 80.9% (95% CI, 68.2-89.3) of patients with malaria received recommended treatment with ACT compared to 70.3% (95% CI, 54.7-82.2) of patients in the pre-RDT implementation area. Correct treatment was significantly higher in the post-implementation area during high transmission season (85.9% (95%CI, 72.0-93.6) compared to 58.3% (95%CI, 39.4-75.1) in pre-implementation area (p = 0.01). Over-treatment with ACT of patients without malaria was less common in the post-RDT implementation area (20.9%; 95% CI, 14.7-28.8) compared to the pre-RDT implementation area (45.8%; 95% CI, 37.2-54.6) (p < 0.01) in high transmission. The odds of overtreatment was significantly lower in post- RDT area (adjusted Odds Ratio (OR: 95%CI) 0.57(0.36-0.89); and much higher with clinical diagnosis adjusted OR (95%CI) 2.24(1.37-3.67) Conclusion Implementation of RDTs increased use of RDTs for parasitological confirmation and reduced over-treatment with ACT during high malaria transmission season in one area in Tanzania. Continued monitoring of the national RDT rollout will be needed to assess whether these changes in case management practices will be replicated in other areas and sustained over time. Additional measures (such as refresher trainings, closer supervisions, etc.) may be needed to improve ACT targeting during low transmission seasons. PMID:22747655
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1992-11-24
This proposed action provides the Department of Energy (DOE) authorization to the US Army to conduct a testing program using Depleted Uranium (DU) in Area 25 at the Nevada Test Site (NTS). The US Army Ballistic Research Laboratory (BRL) would be the managing agency for the program. The proposed action site would utilize existing facilities, and human activity would be confined to areas identified as having no tortoise activity. Two classifications of tests would be conducted under the testing program: (1) open-air tests, and (2) X-Tunnel tests. A series of investigative tests would be conducted to obtain information on DUmore » use under the conditions of each classification. The open-air tests would include DU ammunition hazard classification and combat systems activity tests. Upon completion of each test or series of tests, the area would be decontaminated to meet requirements of DOE Order 5400.5, Radiation Protection of the Public and Environment. All contaminated materials would be decontaminated or disposed of as radioactive waste in an approved low-level Radioactive Waste Management Site (RWMS) by personnel trained specifically for this purpose.« less
Are There Dangerous Levels of Lead in Local Soil?
NASA Astrophysics Data System (ADS)
Pita, I.
2017-12-01
The purpose of this experiment was to show that comparing random soil samples from areas in New Orleans; the Garden District will have the highest levels of lead in soil. My Independent variable was the soil samples collected from locations in the Garden District area of New Orleans, and other locations throughout New Orleans. The control was the soil samples collected from the local playground in the New Orleans area. My dependent variable was the lead soil test kit, using ppm (parts per million) of lead to show concentration. 400 ppm + in bare soil where children play is considered dangerous hazard levels. 1,000 + ppm in all other areas is considered dangerous hazard levels. The first step to my experiment, I collected soil samples from different locations throughout the Garden District area of New Orleans. The second step to my experiment, I conducted the lead soil testing in a controlled area at home in a well ventilated room, using all the necessary safety equipment needed, I began testing a 24 hour test period and a 48 hour test period. I then collected the data from both test. The results showed that soil samples from the Garden District area compared to the other sample locations had higher lead concentrations in the soil. This backed my hypothesis when comparing soil samples from areas in New Orleans, the Garden District will have the highest lead levels. In conclusion these experiments showed that with the soil samples collected, there were higher concentrations of lead in the soil from the Garden District area compared to the other areas where soil was collected. Reconstruction and renovations, from the devastation that Hurricane Katrina created, are evident of the lead in paint of older homes which now show the lead concentration in the soil. Lead is a lethal element if consumed or inhaled in high doses, which can damage key organs in our body, which can be deadly. Better awareness through social media, television, radio, doctors, studies, pamphlets, environmental agencies, and other forms to address the steps in protecting your family and home for a lead free environment.
Wave Energy Prize MASK wave calibration data for the 1:20 scale testing at MASK
Driscoll, Rick
2017-05-08
Time series data, sensor layout, and wave calibration summaries for the wave height measurements for the 10 calibration sea states for the 1:20 scale testing of the Wave Energy Prize (WEP) at the US Navy's Maneuvering and Seakeeping (MASK) Basin at the Naval Surface Warfare Center in Carderock, Maryland. Measurements were made in the test area and upstream of the test area.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Colton, D.P.
1999-12-01
A series of low-altitude, aerial radiological surveys of selected regions within Areas 3, 5, 8, 9, 11, 18,and 25 of the Nevada Test Site was conducted from December 1996 through June 1999. The surveys were conducted for the US Department of Energy by the Remote Sensing Laboratory, located in Las Vegas, Nevada, and maintained and operated by Bechtel Nevada. The flights were conducted at a nominal altitude of 15 meters above ground level along a set of parallel flight lines spaced 23 meters apart. The purpose of these low-altitude surveys was to measure, map, and define the areas of americium-241more » activity. The americium contamination will be used to determine the areas of plutonium contamination. Americium-241 activity was detected within 8 of the 11 regions. The three regions where americium-241 was not detected were in the inactive Nuclear Rocket Development Station complex in Area 25, which encompassed the Test Cell A and Test Cell C reactor test stands and the Reactor Maintenance Assembly and Disassembly facility.« less
Torsional Shear Strength Tests for Glass-Ceramic Joined Silicon Carbide
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ferraris, Monica; Ventrella, Andrea; Salvo, Milena
2014-03-17
A torsion test on hour-glass-shaped samples with a full joined or a ring-shaped joined area was chosen in this study to measure shear strength of glass-ceramic joined silicon carbide. Shear strength of about 100 MPa was measured for full joined SiC with fracture completely inside their joined area. Attempts to obtain this shear strength with a ring-shaped joined area failed due to mixed mode fractures. However, full joined and ring-shaped steel hour-glasses joined by a glass-ceramic gave the same shear strength, thus suggesting that this test measures shear strength of joined components only when their fracture is completely inside theirmore » joined area.« less
The 11th Space Simulation Conference
NASA Technical Reports Server (NTRS)
Bond, A. C. (Editor)
1980-01-01
Subject areas range from specialized issues dealing with the space and entry environments to the environmental testing of systems and complete spacecraft of present-day vintage. Various papers consider: the test and development of several key systems of the orbiter vehicle; integrated tests of complete satellites; new and unique test facilities developed to meet the demanding requirements of high fidelity simulation of test environments; and contamination species, including the instrumentation for detection and measurement of such. Special topics include improved thermal protection methodologies and approaches, sophisticated sensor developments, and other related testing and development areas.
Intraradicular Appearances Affect Radiographic Interpretation of the Periapical Area.
Biscontine, Ana C; Diliberto, Adam J; Hatton, John F; Woodmansey, Karl F
2017-12-01
No research exists evaluating the influences of specific variables such as obturation length, radiodensity, or the presence of voids on interpretation of periradicular area. The purpose of this study was to evaluate the effects of obturation length, radiodensity, and the presence of voids on the radiographic interpretations of periapical areas. In a Web-based survey, 3 test image groups of variable obturation lengths, radiodensities, and numbers of voids were presented to observers for evaluation of the periapical areas. Intracanal areas of the images were altered by using Adobe Photoshop to create 3 test image groups. Each observer reviewed 2 control images and 1 image from each test image group. Responses were recorded in a 5-point Likert-type scale. Within each test image group, the periapical areas were identical. Kruskal-Wallis, Mann-Whitney U, and Cliff's delta statistical tests were used to analyze results. A total of 748 observer responses were analyzed. Significant differences (P ≤ .01) in the median Likert-type scale responses were identified between the following paired groups: 3 mm short and 1 mm short, 3 mm short and flush, lower radiodensity and higher radiodensity, lower radiodensity and intermediate radiodensity, no voids and several voids, and several voids and single void. Effect sizes ranged from 0.19 to 0.41. Significant differences were noted within all 3 test image groups: length, radiodensity, and presence of voids. Length of obturation had the largest effect on interpretation of the periapical area, with the 3 mm short radiographic obturation length image interpreted less favorably. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Rincón-Cortés, Millie; Grace, Anthony A
2017-10-01
Stress constitutes a risk factor across several psychiatric disorders. Moreover, females are more susceptible to stress-related disorders, such as depression, than males. Although dopamine system underactivation is implicated in the pathophysiology of depression, little is known about the female dopamine system at baseline and post-stress. The effects of chronic mild stress were examined on ventral tegmental area dopamine neuron activity and forced swim test immobility by comparing male and female rats. The impact of a single dose of the rapid antidepressant ketamine (10 mg/kg, i.p.) on forced swim test immobility and ventral tegmental area function was then tested. Baseline ventral tegmental area dopamine activity was comparable in both sexes. At baseline, females exhibited roughly double the forced swim test immobility duration than males, which corresponded to ~50% decrease in ventral tegmental area dopamine population activity compared with similarly treated (i.e., post-forced swim test) males. Following chronic mild stress, there was greater immobility duration in both sexes and reduced ventral tegmental area dopamine neuron activity by approximately 50% in males and nearly 75% in females. Ketamine restored behavior and post-forced swim test ventral tegmental area dopamine activity for up to 7 days in females as well as in both male and female chronic mild stress-exposed rats. These data suggest increased female susceptibility to depression-like phenotypes (i.e., greater immobility, ventral tegmental area hypofunction) is associated with higher dopamine system sensitivity to both acute and repeated stress relative to males. Understanding the neural underpinnings of sex differences in stress vulnerability will provide insight into mechanisms of disease and optimizing therapeutic approaches in both sexes. © The Author 2017. Published by Oxford University Press on behalf of CINP.
5. TETHERED MINUTEMAN MISSILE LAUNCH, TEST AREA 1100. Original is ...
5. TETHERED MINUTEMAN MISSILE LAUNCH, TEST AREA 1-100. Original is a color print. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Leuhman Ridge near Highways 58 & 395, Boron, Kern County, CA
GENERAL VIEW OF THE NORTH SECTION OF THE EAST TEST ...
GENERAL VIEW OF THE NORTH SECTION OF THE EAST TEST AREA. THE SATURN V TEST FACILITY (BLDG. 4550) IS TO THE LEFT IN THE PHOTO. THE SATURN I TEST FACILITY (BLDG. 4557) IS IN THE CENTER, THE COLD CALIBRATION TEST STAND (BLDG. 4588) IS THE SHORT STEEL FRAMED STRUCTURE TO THE RIGHT IN THE PHOTO AND THE TURBO PUMP / HIGH VOLUME FLOW FACILITY (BLDG. 4548) IS THE TALL STEEL FRAMED STRUCTURE IN THE RIGHT SIDE OF THE PHOTOGRAPHIC IMAGE. - Marshall Space Flight Center, Saturn V Dynamic Test Facility, East Test Area, Huntsville, Madison County, AL
P-Them Response for Geologically Active and Non-Active Areas
NASA Astrophysics Data System (ADS)
Vetrov, A.
2011-12-01
Time Domain Electromagnetic air-borne systems are widely used in geological exploration for minerals associated with conductive rocks, underground water resources and geological underground mapping. The newly designed P-THEM system has been test-flown at the Reid Mahaffy geological test site in Northern Ontario, Canada; and then over an area near Newmarket, north of Toronto. While the flight in Reid Mahaffy was made to verify real characteristics of the system: stability and repeatability of results, the flight over the Newmarket area was made to verify correct operation of the EM system with a magnetometer and gamma-ray spectrometer. Interesting and significant response of the TDEM observations to geological, agricultural and engineering objects were observed during the test flights. These results demonstrate a possibility of TDEM method for mineral research and environmental tasks. The Reid Mahaffy Test Site is located in the Abitibi Subprovince, immediately east of the Mattagami River Fault in Ontario, Canada. The test site was created in 1999 by the Ontario Geological Survey, initially to enable various airborne geophysical systems to demonstrate their basic performance capabilities. The general geology of the site contains known overburden thickness based on almost 50 diamond drill holes, with geological logs available for these. The survey flights over Reid Mahaffy test site were performed in April 2010. The altitude and direction tests were flown on three lines over the test survey area. The response of early times represents overburden and correlates with its known thickness. The conductive body appears on later time channels and remains detectable over noise level. The electrical inversion of the results allows distinguishing a structure of several vertical conductor slices, forming the conductive body. The Newmarket area selected for tests in June 2010 is a highly developed urban zone in the Greater Toronto Area, Ontario, Canada. Geologically, the area is represented with Quadrennial sediments with underlying bedrocks of the Ordovician formation. The main area is represented with sand and gravel of Glacial lake, River and Moraine deposits. The main purpose of the test flights was to check the functional integration of the P-THEM system with a Magnetometer and Gamma-Ray Spectrometer system. The results indicated a very good agricultural response of the P-THEM system after the interpretation of the observed data. The salty soils along roads, where the salt is spread during winter time, the grounded industrial constructions and powerline towers can be observed on the mapped data (see image). The achieved results of the survey show the possibility of the TDEM airborne system for applications in characterization of environmental and engineering properties, such as detection of surface and near surface pollution, grounding of metal constructions and other, over large areas of interest.
Leptin/LepRb in the Ventral Tegmental Area Mediates Anxiety-Related Behaviors
Liu, Jing; Guo, Ming
2016-01-01
Background: Leptin, an adipose-derived hormone, has been implicated in emotional regulation. We have previously shown that systemic administration of leptin produces anxiolytic-like effects and deletion of the leptin receptor, LepRb, in midbrain dopamine neurons leads to an anxiogenic phenotype. This study investigated whether activation or deletion of LepRb in the ventral tegmental area of adult mice is capable of inducing anxiolytic and anxiogenic effects, respectively. Methods: Mice were cannulated in the ventral tegmental area and received bilateral intra-ventral tegmental area infusions of leptin or the JAK2/STAT3 inhibitor AG490. Anxiety-like behaviors were assessed using the elevated plus-maze, light-dark box, and novelty suppressed feeding tests. Deletion of LepRb in the ventral tegmental area was achieved by bilateral injection of AAV-Cre into the ventral tegmental area of adult Leprflox/flox mice. Anxiety-related behaviors were evaluated 3 weeks after viral injection. Results: Intra-ventral tegmental area infusions of leptin reduced anxiety-like behaviors, as indicated by increased percent open-arm time and open-arm entries in the elevated plus-maze test, increased time spent in the light side and decreased latency to enter the light side of the light-dark box, and decreased latency to feed in the novelty suppressed feeding test. Blockade of JAK2/STAT3 signaling in the ventral tegmental area by AG490 attenuated the anxiolytic effect produced by systemic administration of leptin. Leprflox/flox mice injected with AAV-Cre into the ventral tegmental area showed decreased leptin-induced STAT3 phosphorylation and enhanced anxiety-like behaviors in the elevated plus-maze test and the novelty suppressed feeding test. Conclusions: These findings suggest that leptin-LepRb signaling in the ventral tegmental area plays an important role in the regulation of anxiety-related behaviors. PMID:26438799
CFD Simulations for Arc-Jet Panel Testing Capability Development Using Semi-Elliptical Nozzles
NASA Technical Reports Server (NTRS)
Gokcen, Tahir; Balboni, John A.; Hartman, G. Joseph
2016-01-01
This paper reports computational simulations in support of arc-jet panel testing capability development using semi-elliptical nozzles in a high enthalpy arc-jet facility at NASA Ames Research Center. Two different semi-elliptical nozzle configurations are proposed for testing panel test articles. Computational fluid dynamics simulations are performed to provide estimates of achievable panel surface conditions and useful test area for each configuration. The present analysis comprises three-dimensional simulations of the nonequilibrium flowfields in the semi-elliptical nozzles, test box and flowfield over the panel test articles. Computations show that useful test areas for the proposed two nozzle options are 20.32 centimeters by 20.32 centimeters (8 inches by 8 inches) and 43.18 centimeters by 43.18 centimeters (17 inches by 17 inches). Estimated values of the maximum cold-wall heat flux and surface pressure are 155 watts per centimeters squared and 39 kilopascals for the smaller panel test option, and 44 watts per centimeters squared and 7 kilopascals for the larger panel test option. Other important properties of the predicted flowfields are presented, and factors that limit the useful test area in the semi-free jet test configuration are discussed.
ELECTRICAL LINES ARRIVE FROM CENTRAL FACILITIES AREA, SOUTH OF MTR. ...
ELECTRICAL LINES ARRIVE FROM CENTRAL FACILITIES AREA, SOUTH OF MTR. EXCAVATION RUBBLE IN FOREGROUND. CONTRACTOR CRAFT SHOPS, CRANES, AND OTHER MATERIALS ON SITE. CAMERA FACES EAST, WITH LITTLE BUTTE AND MIDDLE BUTTE IN DISTANCE. INL NEGATIVE NO. 335. Unknown Photographer, 7/1/1950 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
ERIC Educational Resources Information Center
Bayhan Karapinar, Pinar; Metin Camgoz, Selin; Tayfur Ekmekci, Ozge
2016-01-01
The study tests an integrative model that considers the plausible effects of different areas of work life on emotional exhaustion. It also tests the mediating effect of organizational trust on this relationship. More specifically, while perceived incongruence in six areas of work life (workload, fairness, reward, community, control and value) is…
28. View of data test area for DR data take ...
28. View of data test area for DR data take off set operators panel and cabinet at second floor of transmitter building no. 102 in MIP area. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK
REACTOR SERVICES BUILDING, TRA635, INTERIOR. ALSO KNOWN AS MATERIAL RECEIVING ...
REACTOR SERVICES BUILDING, TRA-635, INTERIOR. ALSO KNOWN AS MATERIAL RECEIVING AREA AND LABORATORY. CAMERA ON FIRST FLOOR FACING NORTH TOWARD MTR BUILDING. MOCK-UP AREA WAS TO THE RIGHT OF VIEW. INL NEGATIVE NO. HD46-10-1. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Han, Sun-Young; Kim, Bo-Ra; Ko, Hae-Youn; Kwon, Ho-Keun; Kim, Baek-Il
2016-03-01
The aims of this study were to compare the relationship between red fluorescent plaque (RF plaque) area by Quantitative Light-induced Fluorescence-Digital (QLF-D) and disclosed plaque area by two-tone disclosure, and to assess the bacterial composition of the RF plaque by real time-PCR. Fifty healthy subjects were included and 600 facial surfaces of their anterior teeth were examined. QLF-D was taken on two separate occasions (before and after disclosing), and the RF plaque area was calculated based on Plaque Percent Index (PPI). After disclosing, the stained plaque area was analyzed to investigate the relationship with the RF plaque area. The relationship was evaluated using Pearson correlation and paired t-test. Then, the RF and non-red fluorescent (non-RF) plaque samples were obtained from the same subject for real-time PCR test. Total 10 plaque samples were compared the ratio of the 6 of bacteria using Wilcoxon signed rank test. Regarding the paired t-test, the blue-staining plaque area (9.3±9.2) showed significantly similarity with the RF plaque area (9.1±14.9, p=0.80) at ΔR20, however, the red-staining plaque area (31.6±20.9) presented difference from the RF plaque area (p<0.0001). In addition, bacterial composition of Prevotella intermedia and Streptococcus anginosus was associated with substantially more the RF plaque than the non-RF plaque (p<0.05). The plaque assessment method using QLF-D has potential to detect mature plaque, and the plaque area was associated with the blue-staining area using two-tone disclosure. Copyright © 2015 Elsevier B.V. All rights reserved.
Lightweight aggregate production from claystone and shale in Bangladesh
Parker, Norbert A.; Khan, M.A.
1976-01-01
Muffle furnace tests were made on samples of clay, claystone, and shale collected in the Chittagong and Dacca areas of East Pakistan to determine their amenability to bloating for the commercial production of light-weight aggregate. Several areas, sampled in some detail, were selected for investigation because of their proximity to market, and accessibility to fuel and electricity. Muffle furnace tests show that the clay, claystone, and shale are natural bloaters at temperatures in the 1700? to 2200? F range, and do not require additives. The most desirable deposit, insofar as producing a strong aggregate is concerned, can be determined only by pilot-kiln testing and by crushing-strength tests made on concrete test cylinders. Reserves of suitable raw material are large in both the Chittagong and Dacca areas.
50 CFR 216.165 - Requirements for monitoring and reporting.
Code of Federal Regulations, 2012 CFR
2012-10-01
... which case post-test survey dates must be extended, and (v) for a period of 7 days after the last..., of marine mammals in the Safety Range at the time of detonation based on post-test aerial monitoring... area off Mayport, FL. (2) The test area must be monitored by aerial and shipboard monitoring for the...
50 CFR 216.165 - Requirements for monitoring and reporting.
Code of Federal Regulations, 2010 CFR
2010-10-01
... which case post-test survey dates must be extended, and (v) for a period of 7 days after the last..., of marine mammals in the Safety Range at the time of detonation based on post-test aerial monitoring... area off Mayport, FL. (2) The test area must be monitored by aerial and shipboard monitoring for the...
50 CFR 216.165 - Requirements for monitoring and reporting.
Code of Federal Regulations, 2011 CFR
2011-10-01
... which case post-test survey dates must be extended, and (v) for a period of 7 days after the last..., of marine mammals in the Safety Range at the time of detonation based on post-test aerial monitoring... area off Mayport, FL. (2) The test area must be monitored by aerial and shipboard monitoring for the...
LPT. Shield test facility (TAN646). Sections and details of water ...
LPT. Shield test facility (TAN-646). Sections and details of water management areas. Ralph M. Parsons 1229-17 ANP/GE-6-646-P-3. April 1957. Approved by INEEL Classification Office for public release. INEEL index code no. 037-0646-51-693-107388 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
ERIC Educational Resources Information Center
Settlage, Daniel Murray; Wollscheid, Jim R.
2015-01-01
The Major Field Test is a commonly used assessment instrument, but little emphasis has been put on analyzing student-level subject area indicator scores. The Educational Testing Service recently made these data available to institutions, and it is analyzed here. This analysis builds on previous work by incorporating demographic and programmatic…
Health Behaviors and Standardized Test Scores: The Impact of School Health Climate on Performance
ERIC Educational Resources Information Center
Gunter, Whitney D.; Daly, Kevin
2013-01-01
Research has found that many characteristics are related to performance on standardized tests. Many of these are not necessarily "academic" attributes. One area of this research is on the connection between physical health or lifestyles and test performance. The research that exists in this area is often disconnected with each other and…
1. NORTHWEST SIDE AND SOUTHWEST FRONT. Looking east. Edwards ...
1. NORTHWEST SIDE AND SOUTHWEST FRONT. Looking east. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Firing Control Building, Test Area 1-100, northeast end of Test Area 1-100 Road, Boron, Kern County, CA
50. EAST CORNER OF BUILDING 365 (ARMAMENT TESTING BUILDING) IN ...
50. EAST CORNER OF BUILDING 365 (ARMAMENT TESTING BUILDING) IN BASE SPARES AREA. - Loring Air Force Base, Weapons Storage Area, Northeastern corner of base at northern end of Maine Road, Limestone, Aroostook County, ME
49. NORTHEAST FRONT ELEVATION OF BUILDING 365 (ARMAMENT TESTING BUILDING) ...
49. NORTHEAST FRONT ELEVATION OF BUILDING 365 (ARMAMENT TESTING BUILDING) IN BASE SPARES AREA. - Loring Air Force Base, Weapons Storage Area, Northeastern corner of base at northern end of Maine Road, Limestone, Aroostook County, ME
29 CFR 780.721 - Employment in the particular workweek as test of exemption.
Code of Federal Regulations, 2010 CFR
2010-07-01
... FAIR LABOR STANDARDS ACT Employment by Small Country Elevators Within Area of Production; Exemption... Employment in the particular workweek as test of exemption. The period for determining whether the “area of...
NASA Astrophysics Data System (ADS)
Qin, Le; Xie, HuiMin; Zhu, RongHua; Wu, Dan; Che, ZhiGang; Zou, ShiKun
2014-04-01
This paper investigates the effect of the location of testing area in residual stress measurement by Moiré interferometry combined with hole-drilling method. The selection of the location of the testing area is analyzed from theory and experiment. In the theoretical study, the factors which affect the surface released radial strain ɛ r were analyzed on the basis of the formulae of the hole-drilling method, and the relations between those factors and ɛ r were established. By combining Moiré interferometry with the hole-drilling method, the residual stress of interference-fit specimen was measured to verify the theoretical analysis. According to the analysis results, the testing area for minimizing the error of strain measurement is determined. Moreover, if the orientation of the maximum principal stress is known, the value of strain will be measured with higher precision by the Moiré interferometry method.
Damage suppression system using embedded SMA (shape memory alloy) foils in CFRP laminate structures
NASA Astrophysics Data System (ADS)
Ogisu, Toshimichi; Shimanuki, Masakazu; Kiyoshima, Satoshi; Takaki, Junji; Takeda, Nobuo
2003-08-01
This paper presents an overview of the demonstrator program with respect to the damage growth suppression effects using embedded SMA foils in CFRP laminates. The damage growth suppression effects were demonstrated for the technical verification in order to apply to aircraft structure. In our previous studies, the authors already confirmed the damage growth suppression effects of CFRP laminates with embedded pre-strained SMA foils through both coupon and structural element tests. It was founded that these effects were obtained by the suppression of the strain energy release rate based on the suppression of the crack opening displacement due to the recovery stress of SMA foils through the detail observation of the damage behavior. In this study, these results were verified using the demonstrator test article, which was 1/3-scaled model of commercial airliner fuselage structure. For the demonstration of damage growth suppression effects, the evaluation area was located in the lower panel, which was dominated in tension load during demonstration. The evaluation area is the integrated stiffened panel including both "smart area" (CFRP laminate with embedded pre-strained SMA foils) and "conventional area" (standard CFRP laminate) for the direct comparison. The demonstration was conducted at 80 degree Celsius in smart area and room temperature (RT) in conventional area during quasi-static load-unload test method. As the test results, the demonstrator test article presented that the damage onset strain in the smart area was improved by 30% for compared with the conventional area. Therefore, the successful technical verification of the damage onset/growth suppression effect using the demonstrator presented the feasibility of the application of smart material and structural system to aircraft structures.
Kurosaki, Yohei; Magassouba, N'Faly; Bah, Hadja Aïssatou; Soropogui, Barré; Doré, Amadou; Kourouma, Fodé; Cherif, Mahamoud Sama; Keita, Sakoba; Yasuda, Jiro
2016-10-15
To strengthen the laboratory diagnostic capacity for Ebola virus disease (EVD) in the remote areas of Guinea, we deployed a mobile field laboratory and implemented reverse transcription loop-mediated isothermal amplification (RT-LAMP) for postmortem testing. We tested 896 oral swab specimens and 21 serum samples, using both RT-LAMP and reverse transcription-polymerase chain reaction (RT-PCR). Neither test yielded a positive result, and the results from RT-LAMP and RT-PCR were consistent. More than 95% of the samples were tested within 2 days of sample collection. These results highlight the usefulness of the RT-LAMP assay as an EVD diagnostic testing method in the field or remote areas. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.
Early Steps in Automated Behavior Mapping via Indoor Sensors.
Arsan, Taner; Kepez, Orcun
2017-12-16
Behavior mapping (BM) is a spatial data collection technique in which the locational and behavioral information of a user is noted on a plan layout of the studied environment. Among many indoor positioning technologies, we chose Wi-Fi, BLE beacon and ultra-wide band (UWB) sensor technologies for their popularity and investigated their applicability in BM. We tested three technologies for error ranges and found an average error of 1.39 m for Wi-Fi in a 36 m² test area (6 m × 6 m), 0.86 m for the BLE beacon in a 37.44 m² test area (9.6 m × 3.9 m) and 0.24 m for ultra-wide band sensors in a 36 m² test area (6 m × 6 m). We simulated the applicability of these error ranges for real-time locations by using a behavioral dataset collected from an active learning classroom. We used two UWB tags simultaneously by incorporating a custom-designed ceiling system in a new 39.76 m² test area (7.35 m × 5.41 m). We considered 26 observation points and collected data for 180 s for each point (total 4680) with an average error of 0.2072 m for 23 points inside the test area. Finally, we demonstrated the use of ultra-wide band sensor technology for BM.
Early Steps in Automated Behavior Mapping via Indoor Sensors
Arsan, Taner
2017-01-01
Behavior mapping (BM) is a spatial data collection technique in which the locational and behavioral information of a user is noted on a plan layout of the studied environment. Among many indoor positioning technologies, we chose Wi-Fi, BLE beacon and ultra-wide band (UWB) sensor technologies for their popularity and investigated their applicability in BM. We tested three technologies for error ranges and found an average error of 1.39 m for Wi-Fi in a 36 m2 test area (6 m × 6 m), 0.86 m for the BLE beacon in a 37.44 m2 test area (9.6 m × 3.9 m) and 0.24 m for ultra-wide band sensors in a 36 m2 test area (6 m × 6 m). We simulated the applicability of these error ranges for real-time locations by using a behavioral dataset collected from an active learning classroom. We used two UWB tags simultaneously by incorporating a custom-designed ceiling system in a new 39.76 m2 test area (7.35 m × 5.41 m). We considered 26 observation points and collected data for 180 s for each point (total 4680) with an average error of 0.2072 m for 23 points inside the test area. Finally, we demonstrated the use of ultra-wide band sensor technology for BM. PMID:29258178
[The principle of registration, evaluation and testing of disinfecting preparations].
Röhm-Rodowald, Ewa; Jakimiak, Bozenna; Podgórska, Marta
2008-01-01
Disinfectants are used to produce a state in which the number of living micro-organisms has been reduced to a level which is appropriate to the practical situation. For any products which are included in the Biocidal Directive 98/8/EC, for which specific activity is claimed, test data has to be approved by the regulatory authority and a product license obtained before the product can be offered for sale. Disinfectants can be recorded as biocidal products or medical devices. Presently, it is possible to measure the activity of a product on defined micro-organisms in specified experimental conditions. Efficacy is the result of the use of a product according to a defined application. To allow different requirements in different areas of application, separate tests and pass criteria have been or will be prepared for each of following three areas of application: medical, veterinary and group comprising food, industrial, domestic and institutional areas. The laboratory methods to be used for testing the activity of chemical disinfectants meets the European standards. The tests are categorised on a modular basis as follows: phase 1 tests, phase 2 step 1 tests, phase 2 step 2 tests and phase 3 tests. In order to claim that a product has disinfectant properties, suitable for use in the medical area, the product shall be tested according to European standards: phase 2 step 1 tests, phase 2 step 2 tests. Phase 1 tests are not required to support claims for chemical disinfectants used in human medicine. Only phase 1 tests are required to support claims for active substances for which no particular area of application is specified. Medical devices are subjects to the European Directive 93/42/EEC which requires that a product must carry a CE mark. Disinfectants which are intended specifically by its manufacturer to be used on medical devices are themselves medical devices and so these products, as well as conforming to the instrument disinfection European standards as specified in EN 14885, are also required to carry a CE mark.
4. INSTRUMENT ROOM,INTERIOR, MAIN SPACE. Looking northeast. Edwards Air ...
4. INSTRUMENT ROOM,INTERIOR, MAIN SPACE. Looking northeast. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Firing Control Building, Test Area 1-100, northeast end of Test Area 1-100 Road, Boron, Kern County, CA
Internet testing for Chlamydia trachomatis in England, 2006 to 2010.
Woodhall, Sarah C; Sile, Bersabeh; Talebi, Alireza; Nardone, Anthony; Baraitser, Paula
2012-12-19
In recent years there has been interest in websites as a means of increasing access to free chlamydia tests through the National Chlamydia Screening Programme (NCSP) in England. We aimed to describe and evaluate online access to chlamydia testing within the NCSP. We analysed NCSP chlamydia testing data (2006-2010) for 15-24 year olds from the 71/95 programme areas in England where site codes were available to identify tests ordered through the internet. The characteristics of people using online testing services in 2010 were compared with those testing in general practice (GP) or community sexual and reproductive health (SRH) services. We evaluated 58 websites offering free chlamydia tests through the NCSP, and 32 offering kits on a commercial basis for signposting to clinical service and health promotion advice offered. Between 2006 and 2010, 5% of all tests in the included programme areas were accessed through the internet. The number of internet tests increased from 18 (<1% of all tests) in 2006 to 59,750 in 2010 (6% of all NCSP tests). In 2010 the proportion of NCSP tests accessed online by programme area ranged from <1% to 38%. The proportion of tests with a positive result on the internet was higher than tests from general practice and comparable to those from community SRH services (internet 7.6%; GP 5.6%; Community SRH 8.2%). A higher proportion of people accessing online testing were male, aged 20-24 and reported >1 sexual partner in the past year. Provision of sexual health information and appropriate signposting for those in need of clinical services varied between websites. Service provision within the NCSP was fragmented with multiple providers serving specific geographical catchment areas. Internet testing reaches a population with a relatively high risk of chlamydia infection and appears acceptable to young men, a group that has been difficult to engage with chlamydia testing. In order to maximise the potential benefit of these services, websites should be consistent with national guidelines and adhere to minimum standards for signposting to clinical care and health promotion information. The current system with multiple providers servicing geographically specific catchment areas is contrary to the geographically unrestricted nature of the internet and potentially confusing for clients.
Arcjet nozzle area ratio effects
NASA Technical Reports Server (NTRS)
Curran, Francis M.; Sarmiento, Charles J.; Birkner, Bjorn W.; Kwasny, James
1990-01-01
An experimental investigation was conducted to determine the effect of nozzle area ratio on the operating characteristics and performance of a low power dc arcjet thruster. Conical thoriated tungsten nozzle inserts were tested in a modular laboratory arcjet thruster run on hydrogen/nitrogen mixtures simulating the decomposition products of hydrazine. The converging and diverging sides of the inserts had half angles of 30 and 20 degrees, respectively, similar to a flight type unit currently under development. The length of the diverging side was varied to change the area ratio. The nozzle inserts were run over a wide range of specific power. Current, voltage, mass flow rate, and thrust were monitored to provide accurate comparisons between tests. While small differences in performance were observed between the two nozzle inserts, it was determined that for each nozzle insert, arcjet performance improved with increasing nozzle area ratio to the highest area ratio tested and that the losses become very pronounced for area ratios below 50. These trends are somewhat different than those obtained in previous experimental and analytical studies of low Re number nozzles. It appears that arcjet performance can be enhanced via area ratio optimization.
Arcjet Nozzle Area Ratio Effects
NASA Technical Reports Server (NTRS)
Curran, Francis M.; Sarmiento, Charles J.; Birkner, Bjorn W.; Kwasny, James
1990-01-01
An experimental investigation was conducted to determine the effect of nozzle area ratio on the operating characteristics and performance of a low power dc arcjet thruster. Conical thoriated tungsten nozzle inserts were tested in a modular laboratory arcjet thruster run on hydrogen/nitrogen mixtures simulating the decomposition products of hydrazine. The converging and diverging sides of the inserts had half angles of 30 and 20 degrees, respectively, similar to a flight type unit currently under development. The length of the diverging side was varied to change the area ratio. The nozzle inserts were run over a wide range of specific power. Current, voltage, mass flow rate, and thrust were monitored to provide accurate comparisons between tests. While small differences in performance were observed between the two nozzle inserts, it was determined that for each nozzle insert, arcjet performance improved with increasing nozzle area ratio to the highest area ratio tested and that the losses become very pronounced for area ratios below 50. These trends are somewhat different than those obtained in previous experimental and analytical studies of low Re number nozzles. It appears that arcjet performance can be enhanced via area ratio optimization.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hunter, R.B.
1994-09-01
This report provides the results of monitoring of plants and animals on the Nevada Test Site during calendar year 1993. Monitoring was accomplished under the Department of Energy`s Basic Environmental Compliance and Monitoring Program, initiated in 1987. The program looks at both baseline study areas, chosen to represent undisturbed conditions as much as possible, and areas disturbed by Department of energy (DOE) activities or natural phenomena. DOE disturbances studied include areas blasted by above-ground nuclear tests before 1962, subsidence craters created by underground nuclear tests, road maintenance activities, areas cleared for drilling, and influences of man-made water sources. Natural phenomenamore » studied include recovery from range fires, effects of introduced species, damage to plants by insect outbreaks, and effects of weather fluctuations. In 1993 disturbances examined included several burned areas and roadsides, a drill pad on Pahute Mesa, introduced grasses and shrub removal effects on ephemeral plants, and effects on pine trees of an infestation of pinyon needle scale insects.« less
13. "CIVIL, SITE PLAN AND VICINITY MAP, AREA LOCATIONS." Test ...
13. "CIVIL, SITE PLAN AND VICINITY MAP, AREA LOCATIONS." Test Area 1-125. Specifications No. ENG (NASA)-04-35363-1; Drawing No. 60-09-34; sheet 11. Ref. No. C-l. D.O. SERIES 1597/1. Approved for siting on 24 April 1962. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Leuhman Ridge near Highways 58 & 395, Boron, Kern County, CA
NASA Technical Reports Server (NTRS)
Bryan, B. A.; Tunnel, S. H.
1972-01-01
The data obtained during aerial photography flights using a helicopter are presented. The areas photographed are identified as three areas within Test Site 175: (1) Rosenberg, (2) Houston Ship Channel/Trinity Bay, and (3) the Somerville Dam. Data are presented in the form of charts. Reproductions of the aerial photographs are included.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hillmer, Kurt T.
This course presents information on radiological work permits (RWPs), various types of postings used in radiological areas, radiological area setups, access controls, and releases of material from radiological areas. All of these are fundamental duties of RCTs. This course will prepare the student with the skills necessary for radiological control technician (RCT) qualification by passing quizzes, tests, and the RCT Comprehensive Phase 1, Unit 2 Examination (TEST 27566) and providing in-thefield skills.
33. AS BUILT DRAWING OF TAN 629 HANGAR SHOWING GENERAL ...
33. AS BUILT DRAWING OF TAN 629 HANGAR SHOWING GENERAL SITE PLAN AND RELATIONSHIP BETWEEN FLIGHT ENGINE TEST AREA TO ADMINISTRATION AND MAINTENANCE AREA, RAILROAD TRACKS AT SCALE OF 1 INCH TO 400 FEET. RALPH M. PARSONS DRAWING NUMBER: 1229-2 ANP/GE 5-101. DATED MARCH 15, 1957. - Idaho National Engineering Laboratory, Test Area North, Hangar No. 629, Scoville, Butte County, ID
Frye, Cheryl A.; Walf, Alicia A.
2008-01-01
In the ventral tegmental area, progestogens facilitate sexual receptivity of rodents via actions at dopamine type 1-like and/or γ-aminobutyric type A receptors and activation of downstream signal transduction molecules. In the present study, we investigated whether effects of progesterone’s metabolite, 3α,5α-THP, to enhance lordosis via actions at these receptors in the ventral tegmental area requires phospholipase C-dependent protein kinase C. The objective of this study was to test the hypothesis that: if progestogens’ actions through dopamine type 1-like and/or γ-aminobutyric type A receptors in the ventral tegmental area for lordosis require protein kinase C, then inhibiting protein kinase C in the ventral tegmental area should reduce 3α,5α-THP-facilitated lordosis and its enhancement by dopamine type 1-like or γ-aminobutyric type A receptor agonists. Ovariectomized, E2 (10 μg s.c. at hr 0)-primed rats were tested for their baseline lordosis responses and then received a series of three infusions to the ventral tegmental area: first, bisindolylmaleimide (75 nM/side) or vehicle; second, SKF38393 (100 ng/side), muscimol (100 ng/side), or vehicle; third, 3α,5α-THP (100, 200 ng) or vehicle. Rats were pre-tested for lordosis and motor behavior and then tested for lordosis after each infusion and 10 and 60 mins after the last infusion. Rats were tested for motor behavior following their last lordosis test. As has been previously demonstrated, 3α,5α-THP infusions to the ventral tegmental area increased lordosis and effects were further enhanced by infusions of SKF38393 and muscimol. Infusions of bisindolylmaleimide to the ventral tegmental area attenuated 3α,5α-THP-, SKF38393-, and/or muscimol-facilitated lordosis. Effects on lordosis were not solely due to changes in general motor behavior. Thus, 3α,5α-THP’s actions in the ventral tegmental area through membrane receptors may require activity of protein kinase C. PMID:18675324
Potential over request in anemia laboratory tests in primary care in Spain.
Salinas, María; López-Garrigós, Maite; Flores, Emilio; Uris, Joaquín; Leiva-Salinas, Carlos
2015-07-01
The aim was to study the inter-practice variability in anemia laboratory tests requested by general practitioners in Spain, to evaluate for a potential requesting inappropriateness. Laboratories from diverse Spanish regions filled out the number of cell blood count, ferritin, folate, iron, transferrin, and vitamin B12 requested by general practitioners during 2012. The number of test requests per 1000 inhabitants and ratios of related tests requests were calculated. The results obtained in hospitals from different areas (urban, rural, or urban-rural), type of management (public or private), and geographic regions were compared. There was a high variability in the number of test requests and ratios of related tests. Cell blood count was over requested in rural areas and in hospitals with private management. Andalucía was the community with the lowest number of iron requests and the lowest folate/vitamin B12 indicator value. Iron and transferrin seemed over requested in some areas; as were folate and ferritin when compared to vitamin B12 and cell blood count, respectively. The differences observed between areas indicate that other factors besides clinical reasons could be behind that variability and emphasize the need to accomplish interventions to improve the appropriate use of anemia laboratory tests.
ERIC Educational Resources Information Center
Li, Ying; Jiao, Hong; Lissitz, Robert W.
2012-01-01
This study investigated the application of multidimensional item response theory (IRT) models to validate test structure and dimensionality. Multiple content areas or domains within a single subject often exist in large-scale achievement tests. Such areas or domains may cause multidimensionality or local item dependence, which both violate the…
8. BUILDING NO. 611. INTERIOR OF ARMOR PLATELINED TESTING CHAMBER. ...
8. BUILDING NO. 611. INTERIOR OF ARMOR PLATE-LINED TESTING CHAMBER. 1/2' THICK ARMOR PLATING BOLTED TO WALLS, FLOOR AND CEILING. WALLS CONSTRUCTED OF 24' THICK REINFORCED CONCRETE. VENTS IN CEILING EXHAUST SMOKE FROM EXPLOSIONS. SMALLEST WHEELED VEHICLES HOLD DUDS. - Picatinny Arsenal, 600 Area, Test Areas District, State Route 15 near I-80, Dover, Morris County, NJ
2007-05-01
Bioaugmentation of Source Areas Dover National Test Site, Dover, Delaware ESTCP Project Number ER-0008 May 2007 Revision 3.0 ER0008 ii...2007.05.24 Revision 3.0 TABLE OF CONTENTS Page 1. INTRODUCTION...ER0008 iii 2007.05.24 Revision 3.0 3.5 Testing and Evaluation Plan
The Testing Methods and Gender Differences in Multiple-Choice Assessment
NASA Astrophysics Data System (ADS)
Ng, Annie W. Y.; Chan, Alan H. S.
2009-10-01
This paper provides a comprehensive review of the multiple-choice assessment in the past two decades for facilitating people to conduct effective testing in various subject areas. It was revealed that a variety of multiple-choice test methods viz. conventional multiple-choice, liberal multiple-choice, elimination testing, confidence marking, probability testing, and order-of-preference scheme are available for use in assessing subjects' knowledge and decision ability. However, the best multiple-choice test method for use has not yet been identified. The review also indicated that the existence of gender differences in multiple-choice task performance might be due to the test area, instruction/scoring condition, and item difficulty.
Salomaa, Sisko; Lindholm, Carita; Tankimanova, Maira K; Mamyrbaeva, Zaure Zh; Koivistoinen, Armi; Hultén, Maj; Mustonen, Riitta; Dubrova, Yuri E; Bersimbaev, Rakhmetkaji I
2002-11-01
SalomaTranslocation analysis using FISH (fluorescence in situ hybridization) chromosome painting was performed to evaluate the magnitude of exposure to ionizing radiation among the human population living close to the Semipalatinsk nuclear test site in Kazakhstan. We studied two generations of people living in villages that were in the path of the radioactive cloud from the first Soviet surface nuclear test performed in August 1949 and from later tests. The older generation (P(0)) lived in the area at the time of testing, and the younger generation (F(1)) was exposed to smaller doses from the residual fallout and later tests. In both P(0) and F(1) generations, similar translocation frequencies were observed in persons living in either the Semipalatinsk area or a noncontaminated area. Assuming translocation stability in peripheral blood lymphocytes over several decades, these findings suggest that on average, the magnitude of exposure of this cohort in the Semipalatinsk area has been considerably smaller than that reported in the literature. Previously reported doses of the order of 1-4.5 Gy (mean 2.9 Gy in the P(0) generation) cannot be confirmed by the present data.
Kasabova, Boryana E; Holliday, Trenton W
2015-04-01
A new model for estimating human body surface area and body volume/mass from standard skeletal metrics is presented. This model is then tested against both 1) "independently estimated" body surface areas and "independently estimated" body volume/mass (both derived from anthropometric data) and 2) the cylindrical model of Ruff. The model is found to be more accurate in estimating both body surface area and body volume/mass than the cylindrical model, but it is more accurate in estimating body surface area than it is for estimating body volume/mass (as reflected by the standard error of the estimate when "independently estimated" surface area or volume/mass is regressed on estimates derived from the present model). Two practical applications of the model are tested. In the first test, the relative contribution of the limbs versus the trunk to the body's volume and surface area is compared between "heat-adapted" and "cold-adapted" populations. As expected, the "cold-adapted" group has significantly more of its body surface area and volume in its trunk than does the "heat-adapted" group. In the second test, we evaluate the effect of variation in bi-iliac breadth, elongated or foreshortened limbs, and differences in crural index on the body's surface area to volume ratio (SA:V). Results indicate that the effects of bi-iliac breadth on SA:V are substantial, while those of limb lengths and (especially) the crural index are minor, which suggests that factors other than surface area relative to volume are driving morphological variation and ecogeographical patterning in limb prorportions. © 2014 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Priebe, Elizabeth H.; Neville, C. J.; Rudolph, D. L.
2018-03-01
The spatial coverage of hydraulic conductivity ( K) values for large-scale groundwater investigations is often poor because of the high costs associated with hydraulic testing and the large areas under investigation. Domestic water wells are ubiquitous and their well logs represent an untapped resource of information that includes mandatory specific-capacity tests, from which K can be estimated. These specific-capacity tests are routinely conducted at such low pumping rates that well losses are normally insignificant. In this study, a simple and practical approach to augmenting high-quality K values with reconnaissance-level K values from water-well specific-capacity tests is assessed. The integration of lesser quality K values from specific-capacity tests with a high-quality K data set is assessed through comparisons at two different scales: study-area-wide (a 600-km2 area in Ontario, Canada) and in a single geological formation within a portion of the broader study area (200 km2). Results of the comparisons demonstrate that reconnaissance-level K estimates from specific-capacity tests approximate the ranges and distributions of the high-quality K values. Sufficient detail about the physical basis and assumptions that are invoked in the development of the approach are presented here so that it can be applied with confidence by practitioners seeking to enhance their spatial coverage of K values with specific-capacity tests.
An overview of current activities at the National Solar Thermal Test Facility
NASA Astrophysics Data System (ADS)
Cameron, C. P.; Klimas, P. C.
This paper is a description of the United States Department of Energy's National Solar Thermal Test Facility, highlighting current test programs. In the central receiver area, research underway supports commercialization of molten nitrate salt technology, including receivers, thermal energy transport, and corrosion experiments. Concentrator research includes large-area, glass-metal heliostats and stretched-membrane heliostats and dishes. Test activities in support of dish-Stirling systems with reflux receivers are described. Research on parabolic troughs includes characterization of several receiver configurations. Other test facility activities include solar detoxification experiments, design assistance testing of commercially-available solar hardware, and non-DOE-funded work, including thermal exposure tests and testing of volumetric and PV central receiver concepts.
Evaluation of TravInfo field operational test
DOT National Transportation Integrated Search
2000-04-25
This document constitutes the final report of the evaluation of the TravInfo field operational test. TravInfo is a regional traveler information system in operation in the San Francisco Bay Area. The focus of the evaluation was on three areas: instit...
6. UNDERGROUND FIRING CONTROL ROOM, INTERIOR. Looking southeast to escape ...
6. UNDERGROUND FIRING CONTROL ROOM, INTERIOR. Looking southeast to escape tunnel. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Firing Control Building, Test Area 1-100, northeast end of Test Area 1-100 Road, Boron, Kern County, CA
1. MINUTEMAN SILO INTERIOR (MARCH 1961). Looking down a silo. ...
1. MINUTEMAN SILO INTERIOR (MARCH 1961). Looking down a silo. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Missile Silo Type, Test Area 1-100, northeast end of Test Area 1-100 Road, Boron, Kern County, CA
DETAIL VIEW OF ELECTRONICS TEST AREA, FLIGHT KITS FACILITY, ROOM ...
DETAIL VIEW OF ELECTRONICS TEST AREA, FLIGHT KITS FACILITY, ROOM NO. 1N12, FACING WEST - Cape Canaveral Air Force Station, Launch Complex 39, Vehicle Assembly Building, VAB Road, East of Kennedy Parkway North, Cape Canaveral, Brevard County, FL
Oduyebo, Titilope; Igbinosa, Irogue; Petersen, Emily E; Polen, Kara N D; Pillai, Satish K; Ailes, Elizabeth C; Villanueva, Julie M; Newsome, Kim; Fischer, Marc; Gupta, Priya M; Powers, Ann M; Lampe, Margaret; Hills, Susan; Arnold, Kathryn E; Rose, Laura E; Shapiro-Mendoza, Carrie K; Beard, Charles B; Muñoz, Jorge L; Rao, Carol Y; Meaney-Delman, Dana; Jamieson, Denise J; Honein, Margaret A
2016-07-25
CDC has updated its interim guidance for U.S. health care providers caring for pregnant women with possible Zika virus exposure, to include the emerging data indicating that Zika virus RNA can be detected for prolonged periods in some pregnant women. To increase the proportion of pregnant women with Zika virus infection who receive a definitive diagnosis, CDC recommends expanding real-time reverse transcription-polymerase chain reaction (rRT-PCR) testing. Possible exposures to Zika virus include travel to or residence in an area with active Zika virus transmission, or sex* with a partner who has traveled to or resides in an area with active Zika virus transmission without using condoms or other barrier methods to prevent infection.(†) Testing recommendations for pregnant women with possible Zika virus exposure who report clinical illness consistent with Zika virus disease(§) (symptomatic pregnant women) are the same, regardless of their level of exposure (i.e., women with ongoing risk for possible exposure, including residence in or frequent travel to an area with active Zika virus transmission, as well as women living in areas without Zika virus transmission who travel to an area with active Zika virus transmission, or have unprotected sex with a partner who traveled to or resides in an area with active Zika virus transmission). Symptomatic pregnant women who are evaluated <2 weeks after symptom onset should receive serum and urine Zika virus rRT-PCR testing. Symptomatic pregnant women who are evaluated 2-12 weeks after symptom onset should first receive a Zika virus immunoglobulin (IgM) antibody test; if the IgM antibody test result is positive or equivocal, serum and urine rRT-PCR testing should be performed. Testing recommendations for pregnant women with possible Zika virus exposure who do not report clinical illness consistent with Zika virus disease (asymptomatic pregnant women) differ based on the circumstances of possible exposure. For asymptomatic pregnant women who live in areas without active Zika virus transmission and who are evaluated <2 weeks after last possible exposure, rRT-PCR testing should be performed. If the rRT-PCR result is negative, a Zika virus IgM antibody test should be performed 2-12 weeks after the exposure. Asymptomatic pregnant women who do not live in an area with active Zika virus transmission, who are first evaluated 2-12 weeks after their last possible exposure should first receive a Zika virus IgM antibody test; if the IgM antibody test result is positive or equivocal, serum and urine rRT-PCR should be performed. Asymptomatic pregnant women with ongoing risk for exposure to Zika virus should receive Zika virus IgM antibody testing as part of routine obstetric care during the first and second trimesters; immediate rRT-PCR testing should be performed when IgM antibody test results are positive or equivocal. This guidance also provides updated recommendations for the clinical management of pregnant women with confirmed or possible Zika virus infection. These recommendations will be updated when additional data become available.
3. VIEW LOOKING NORTH, COMPONENTS TEST LABORATORY, DYNAMIC TEST FACILITY ...
3. VIEW LOOKING NORTH, COMPONENTS TEST LABORATORY, DYNAMIC TEST FACILITY (SATURN V IN BACKGROUND). - Marshall Space Flight Center, East Test Area, Components Test Laboratory, Huntsville, Madison County, AL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Irene Farnham
This Quality Assurance Project Plan (QAPP) provides the overall quality assurance (QA) program requirements and general quality practices to be applied to the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO) Underground Test Area (UGTA) Sub-Project (hereafter the Sub-Project) activities. The requirements in this QAPP are consistent with DOE Order 414.1C, Quality Assurance (DOE, 2005); U.S. Environmental Protection Agency (EPA) Guidance for Quality Assurance Project Plans for Modeling (EPA, 2002); and EPA Guidance on the Development, Evaluation, and Application of Environmental Models (EPA, 2009). The QAPP Revision 0 supersedes DOE--341, Underground Test Area Quality Assurancemore » Project Plan, Nevada Test Site, Nevada, Revision 4.« less
22. STATIC TEST TOWER VIEW OF TEST CELLS AND F1 ...
22. STATIC TEST TOWER VIEW OF TEST CELLS AND F-1 TEST LOCK DOWN FOR ENGINE. - Marshall Space Flight Center, Saturn Propulsion & Structural Test Facility, East Test Area, Huntsville, Madison County, AL
Drinking water test methods in crisis-afflicted areas: comparison of methods under field conditions.
Merle, Roswitha; Bleul, Ingo; Schulenburg, Jörg; Kreienbrock, Lothar; Klein, Günter
2011-11-01
To simplify the testing of drinking water in crisis-afflicted areas (as in Kosovo in 2007), rapid test methods were compared with the standard test. For Escherichia coli and coliform pathogens, rapid tests were made available: Colilert(®)-18, P/A test with 4-methylumbelliferyl-β-D-glucoronid, and m-Endo Broth. Biochemical differentiation was carried out by Enterotube™ II. Enterococci were determined following the standard ISO test and by means of Enterolert™. Four hundred ninety-nine water samples were tested for E. coli and coliforms using four methods. Following the standard method, 20.8% (n=104) of the samples contained E. coli, whereas the rapid tests detected between 19.6% (m-Endo Broth, 92.0% concordance) and 20.0% (concordance: 93.6% Colilert-18 and 94.8% P/A-test) positive samples. Regarding coliforms, the percentage of concordant results ranged from 98.4% (P/A-test) to 99.0% (Colilert-18). Colilert-18 and m-Endo Broth detected even more positive samples than the standard method did. Enterococci were detected in 93 of 573 samples by the standard method, but in 92 samples by Enterolert (concordance: 99.5%). Considering the high-quality equipment and time requirements of the standard method, the use of rapid tests in crisis-afflicted areas is sufficiently reliable.
NASA Astrophysics Data System (ADS)
Roşca, S.; Bilaşco, Ş.; Petrea, D.; Fodorean, I.; Vescan, I.; Filip, S.; Măguţ, F.-L.
2015-11-01
The existence of a large number of GIS models for the identification of landslide occurrence probability makes difficult the selection of a specific one. The present study focuses on the application of two quantitative models: the logistic and the BSA models. The comparative analysis of the results aims at identifying the most suitable model. The territory corresponding to the Niraj Mic Basin (87 km2) is an area characterised by a wide variety of the landforms with their morphometric, morphographical and geological characteristics as well as by a high complexity of the land use types where active landslides exist. This is the reason why it represents the test area for applying the two models and for the comparison of the results. The large complexity of input variables is illustrated by 16 factors which were represented as 72 dummy variables, analysed on the basis of their importance within the model structures. The testing of the statistical significance corresponding to each variable reduced the number of dummy variables to 12 which were considered significant for the test area within the logistic model, whereas for the BSA model all the variables were employed. The predictability degree of the models was tested through the identification of the area under the ROC curve which indicated a good accuracy (AUROC = 0.86 for the testing area) and predictability of the logistic model (AUROC = 0.63 for the validation area).
ERIC Educational Resources Information Center
Matlock, Ki Lynn
2013-01-01
When test forms that have equal total test difficulty and number of items vary in difficulty and length within sub-content areas, an examinee's estimated score may vary across equivalent forms, depending on how well his or her true ability in each sub-content area aligns with the difficulty of items and number of items within these areas.…
1977-09-01
species and orders of animals were considered, and several types were selected for preliminary tests at Southwest Research Institute (SRI), Sanl Antonio...character. Figures 1 and 2 give an overview of the test area. The Wisconsin Driftless Area, in general, is partly covered with a fine, humus soil, but...elevation along the southern border. Trees (scrub oak) were scattered over most of the area with somne parts characterized as thickets. Other parts of the
NASA Technical Reports Server (NTRS)
Smith, C. B.
1982-01-01
The Fymat analytic inversion method for retrieving a particle-area distribution function from anomalous diffraction multispectral extinction data and total area is generalized to the case of a variable complex refractive index m(lambda) near unity depending on spectral wavelength lambda. Inversion tests are presented for a water-haze aerosol model. An upper-phase shift limit of 5 pi/2 retrieved an accurate peak area distribution profile. Analytical corrections using both the total number and area improved the inversion.
Pilot interaction with automated airborne decision making systems
NASA Technical Reports Server (NTRS)
Rouse, W. B.; Hammer, J. M.; Mitchell, C. M.; Morris, N. M.; Lewis, C. M.; Yoon, W. C.
1985-01-01
Progress was made in the three following areas. In the rule-based modeling area, two papers related to identification and significane testing of rule-based models were presented. In the area of operator aiding, research focused on aiding operators in novel failure situations; a discrete control modeling approach to aiding PLANT operators was developed; and a set of guidelines were developed for implementing automation. In the area of flight simulator hardware and software, the hardware will be completed within two months and initial simulation software will then be integrated and tested.
Fenelon, Joseph M.; Sweetkind, Donald S.; Laczniak, Randell J.
2010-01-01
Contaminants introduced into the subsurface of the Nevada Test Site by underground nuclear testing are of concern to the U.S. Department of Energy and regulators responsible for protecting human health and safety. The potential for contaminant movement away from the underground test areas and into the accessible environment is greatest by groundwater transport. The primary hydrologic control on this transport is evaluated and examined through a series of contour maps developed to represent the hydraulic-head distribution within each of the major aquifers underlying the area. Aquifers were identified and their extents delineated by merging and analyzing multiple hydrostratigraphic framework models developed by other investigators from existing geologic information. A map of the hydraulic-head distribution in each major aquifer was developed from a detailed evaluation and assessment of available water-level measurements. Multiple spreadsheets that accompany this report provide pertinent water-level and geologic data by well or drill hole. Aquifers are mapped and discussed in general terms as being one of two types: alluvial-volcanic, or carbonate. Both aquifer types are subdivided and mapped as independent regional and local aquifers, based on the continuity of their component rock. Groundwater-flow directions, approximated from potentiometric contours that were developed from the hydraulic-head distribution, are indicated on the maps and discussed for each of the regional aquifers and for selected local aquifers. Hydraulic heads vary across the study area and are interpreted to range in altitude from greater than 5,000 feet in a regional alluvial-volcanic aquifer beneath a recharge area in the northern part of the study area to less than 2,300 feet in regional alluvial-volcanic and carbonate aquifers in the southwestern part of the study area. Flow directions throughout the study area are dominantly south-southwest with some local deviations. Vertical hydraulic gradients between aquifer types are downward throughout most of the study area; however, flow from the alluvial-volcanic aquifer into the underlying carbonate aquifer, where both aquifers are present, is believed to be minor because of an intervening confining unit. Limited exchange of water between aquifer types occurs by diffuse flow through the confining unit, by focused flow along fault planes, or by direct flow where the confining unit is locally absent. Interflow between regional aquifers is evaluated and mapped to define major flow paths. These flow paths delineate tributary flow systems, which converge to form intermediate and regional flow systems. The implications of these flow systems in controlling transport of radionuclides away from the underground test areas at the Nevada Test Site are briefly discussed. Additionally, uncertainties in the delineation of aquifers, the development of potentiometric contours, and the identification of flow systems are identified and evaluated. Eleven tributary flow systems and three larger flow systems are mapped in the Nevada Test Site area. Flow systems within the alluvial-volcanic aquifer dominate the western half of the study area, whereas flow systems within the carbonate aquifer are most prevalent in the southeastern half of the study area. Most of the flow in the regional alluvial-volcanic aquifer that moves through the underground testing area on Pahute Mesa is discharged to the land surface at springs and seeps in Oasis Valley. Flow in the regional carbonate aquifer is internally compartmentalized by major geologic structures, primarily thrust faults, which constrain flow into separate corridors. Contaminants that reach the regional carbonate aquifer from testing areas in Yucca and Frenchman Flats flow toward downgradient discharge areas through the Alkali Flat-Furnace Creek Ranch or Ash Meadows flow systems and their tributaries.
11. BUILDING NO. 620B. INTERIOR VIEW LOOKING NORTH, SHOWING PENDULUM ...
11. BUILDING NO. 620-B. INTERIOR VIEW LOOKING NORTH, SHOWING PENDULUM AND FRAME IN FOREGROUND, SHIELD FOR OPERATORS IN BACKGROUND. FRICTION TEST IS OBSERVED FROM BEHIND BLAST SHIELD BY A SERIES OF MIRRORS. ANVIL IN CENTER OF PENDULUM FRAME HOLDS EXPLOSIVE WHOSE SENSITIVITY TO FRICTION IS TO BE TESTED. PANS ON EITHER SIDE CATCH ANY UNBURNT EXPLOSIVE SLUNG FROM ANVIL DURING TEST TO PREVENT EXPLOSIVE HAZARD. - Picatinny Arsenal, 600 Area, Test Areas District, State Route 15 near I-80, Dover, Morris County, NJ
Evaluation of new spectral bands for multi-spectral imaging: SMIRR aircraft test results
Goetz, Alexander F.H.; Rowan, Lawrence C.; Barringer, Anthony R.
1980-01-01
A 10-channel radiometer called the Shuttle Multispectral Infrared Radiometer (SMIRR) is scheduled to take data from orbit on the second shuttle orbital light test. As part of the instrument test sequence, a series of aircraft flights was carried out over 10 test areas in Utah and Nevada. Apart from vegetation, the materials exposed at the surface were volcanic sequences ranging from tuffs to basalts, areas of hydrothermally altered volcanic rocks, sedimentary sequences of sandstone and carbonate rocks, and alluvial cover.
Field Testing Unvented Roofs with Asphalt Shingles in Cold and Hot-Humid Climates
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ueno, Kohta; Lstiburek, Joseph W.
2015-09-01
Test houses with unvented roof assemblies were built to measure long-term moisture performance, in the Chicago area (5A) and the Houston area (2A). The Chicago-area test bed had seven experimental rafter bays, including a control vented compact roof, and six unvented roof variants with cellulose or fiberglass insulation. The interior was run at 50% RH. The Houston-area roof was an unvented attic insulated with spray-applied fiberglass. Most ridges and hips were built with a diffusion vent detail, capped with vapor permeable roof membrane. In contrast, the diffusion vent roofs had drier conditions at the roof peak in wintertime, but duringmore » the summer, RHs and MCs were higher than the unvented roof (albeit in the safe range).« less
A Large Lunar Surface Testbed from Low Cost Material
NASA Technical Reports Server (NTRS)
Rickman, Douglas
2014-01-01
For users needing to simulate the lunar surface, several distinct avenues have been used. Numerous volcanic areas, including Hawaii, have been used. While providing very large areas and scenic interest, field parties to such an area is expensive and limits testing time. An alternative is to build test facilities locally. This has been done many ways, contrast GRC-1, GSC-1, BP-1 and the KSC Morpheus facility [1-4]. GRC-1 is a mixture of sand and clay; GSC-1 and BP-1 are waste materials created in the process of crushing basaltic rock. The Morpheus field used salvaged concrete and crushed quartz rock [5]. Here I report about a 30 m X 30 m test area at MSFC which was both low cost and relatively high fidelity [6].
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bechtel Nevada
1998-09-30
This corrective action plan proposes the closure method for the area 9 unexploded Ordnance landfill, corrective action unit 453 located at the Tonopah Test Range. The area 9 UXO landfill consists of corrective action site no. 09-55-001-0952 and is comprised of three individual landfill cells designated as A9-1, A9-2, and A9-3. The three landfill cells received wastes from daily operations at area 9 and from range cleanups which were performed after weapons testing. Cell locations and contents were not well documented due to the unregulated disposal practices commonly associated with early landfill operations. However, site process knowledge indicates that themore » landfill cells were used for solid waste disposal, including disposal of UXO.« less
20. UNCOVERED TEST CELL AT THE STATIC TEST TOWER ON ...
20. UNCOVERED TEST CELL AT THE STATIC TEST TOWER ON THE WEST SIDE WHERE F-1 ENGINE WAS TESTED. - Marshall Space Flight Center, Saturn Propulsion & Structural Test Facility, East Test Area, Huntsville, Madison County, AL
Booth, Amy R; Norman, Paul; Harris, Peter R; Goyder, Elizabeth
2014-02-01
The study sought to (1) explain intentions to get tested for chlamydia regularly in a group of young people living in deprived areas using the theory of planned behaviour (TPB); and (2) test whether self-identity explained additional variance in testing intentions. A cross-sectional design was used for this study. Participants (N = 278, 53% male; M = 17.05 years) living in deprived areas of a UK city were recruited from a vocational education setting. Participants completed a self-administered questionnaire, including measures of attitude, injunctive subjective norm, descriptive norm, perceived behavioural control, self-identity, intention and past behaviour in relation to getting tested for chlamydia regularly. The TPB explained 43% of the variance in chlamydia testing intentions with all variables emerging as significant predictors. However, self-identity explained additional variance in intentions (ΔR(2) = .22) and emerged as the strongest predictor, even when controlling for past behaviour. The study identified the key determinants of intention to get tested for chlamydia regularly in a sample of young people living in areas of increased deprivation: a hard-to-reach, high-risk population. The findings indicate the key variables to target in interventions to promote motivation to get tested for chlamydia regularly in equivalent samples, amongst which self-identity is critical. What is already known on this subject? Young people living in deprived areas have been identified as an at-risk group for chlamydia. Qualitative research has identified several themes in relation to factors affecting the uptake of chlamydia testing, which fit well with the constructs of the Theory of Planned Behaviour (TPB). Identity concerns have also been identified as playing an important part in young people's chlamydia testing decisions. What does this study add? TPB explained 43% of the variance in chlamydia testing intentions and all variables were significant predictors. Self-identity explained additional 22% of the variance in intentions and emerged as the strongest predictor. Indicates key variables to target in interventions to promote regular chlamydia testing in deprived young people. © 2013 The British Psychological Society.
8. STATIC TEST TOWER NORTHWEST ELEVATION FROM THE POWER ...
8. STATIC TEST TOWER - NORTHWEST ELEVATION FROM THE POWER PLANT TEST STAND. - Marshall Space Flight Center, Saturn Propulsion & Structural Test Facility, East Test Area, Huntsville, Madison County, AL
Ground Characterization Studies in Canakkale Pilot Site of LIQUEFACT Project
NASA Astrophysics Data System (ADS)
Ozcep, F.; Oztoprak, S.; Aysal, N.; Bozbey, I.; Tezel, O.; Ozer, C.; Sargin, S.; Bekin, E.; Almasraf, M.; Cengiz Cinku, M.; Ozdemir, K.
2017-12-01
The our aim is to outline the ground characterisation studies in Canakkale test site. Study is based on the EU H2020 LIQUEFACT project entitled "Liquefact: Assessment and mitigation of liquefaction potential across Europe: a holistic approach to protect structures / infrastructures for improved resilience to earthquake-induced liquefaction disasters". Objectives and extent of ground characterization for Canakkale test site includes pre-existing soil investigation studies and complementary field studies. There were several SPT and geophysical tests carried out in the study area. Within the context of the complementary tests, six (6) study areas in the test site were chosen and complementary tests were carried out in these areas. In these areas, additional boreholes were opened and SPT tests were performed. It was decided that additional CPT (CPTU and SCPT) and Marchetti Dilatometer (DMT) tests should be carried out within the scope of the complementary testing. Seismic refraction, MASW and micro tremor measurements had been carried out in pre-existing studies. Shear wave velocities obtained from MASW measurements were evaluated to the most rigorous level. These tests were downhole seismic, PS-logging, seismic refraction, 2D-ReMi, MASW, micro tremor (H/V Nakamura method), 2D resistivity and resonance acoustic profiling (RAP). RAP is a new technique which will be explained briefly in the relevant section. Dynamic soil properties had not been measured in pre-existing studies, therefore these properties were investigated within the scope of the complementary tests. Selection of specific experimental tests of the complementary campaign was based on cost-benefit considerations Within the context of complementary field studies, dynamic soil properties were measured using resonant column and cyclic direct shear tests. Several sieve analyses and Atterberg Limits tests which were documented in the pre-existing studies were evaluated. In the complementary study carried out, additional sieve analyses and Atterberg Limit tests were carried out. It was aimed to make some correlations between geophysical measurements and other field measurements; such as SPT, blow count values.
Update on results of SPRE testing at NASA Lewis
NASA Technical Reports Server (NTRS)
Cairelli, James E.; Swec, Diane M.; Wong, Wayne A.; Doeberling, Thomas J.; Madi, Frank J.
1991-01-01
The Space Power Research Engine (SPRE), a free-piston Stirling engine with a linear alternator, is being tested at NASA Lewis Research Center as part of the Civilian Space Technology Initiative (CSTI) as a candidate for high capacity space power. Results are presented from recent SPRE tests designed to investigated the effects of variation in the displacer seal clearance and piston centering port area on engine performance and dynamics. The impact of these variations on PV power and efficiency are presented. Comparisons of the displacer seal clearance tests results with HFAST code predictions show good agreement for PV power, but show poor agreement for PV efficiency. Correlations are presented relating the piston midstroke position to the dynamic Delta P across the piston and the centering port area. Test results indicate that a modest improvement in PV power and efficiency may be realized with a reduction in piston centering port area.
Update on results of SPRE testing at NASA Lewis
NASA Technical Reports Server (NTRS)
Cairelli, James E.; Swec, Diane M.; Wong, Wayne A.; Doeberling, Thomas J.; Madi, Frank J.
1991-01-01
The Space Power Research Engine (SPRE), a free-piston Stirling engine with a linear alternator, is being tested at NASA Lewis Research Center as part of the Civilian Space Technology Initiative (CSTI) as a candidate for high capacity space power. Results are presented from recent SPRE tests designed to investigate the effects of variation in the displacer seal clearance and piston centering port area on engine performance and dynamics. The effects of these variations on PV power and efficiency are presented. Comparisons of the displacer seal clearance test results with HFAST code predictions show good agreement for PV power but poor agreement for PV efficiency. Correlations are presented relating the piston mid-stroke position to the dynamic Delta P across the piston and the centering port area. Test results indicate that a modest improvement in PV power and efficiency may be realized with a reduction in piston centering port area.
VIEW OF EAST TEST SITE FROM TOP OF STATIC TEST ...
VIEW OF EAST TEST SITE FROM TOP OF STATIC TEST TOWER VIEW INCLUDES STRUCTURAL DYNAMICS TEST STAND COLD CALIBRATION TEST STAND AND COMPONENTS TEST LAB. - Marshall Space Flight Center, East Test Area, Dodd Road, Huntsville, Madison County, AL
Flood Assessment Area 3 Radioactive Waste Management Site, Nevada Test Site, Nye County, Nevada
DOE Office of Scientific and Technical Information (OSTI.GOV)
NSTec Environmental Management
2007-07-01
A flood assessment was conducted at the Area 3 Radioactive Waste Management Site (RWMS) at the Nevada Test Site (NTS) in Nye County, Nevada (Figure 1-1). The study area encompasses the watershed of Yucca Flat, a closed basin approximately 780 square kilometers (km2) (300 square miles) in size. The focus of this effort was on a drainage area of approximately 94 km2 (36 mi2), determined from review of topographic maps and aerial photographs to be the only part of the Yucca Flat watershed that could directly impact the Area 3 RWMS. This smaller area encompasses portions of the Halfpint Range,more » including Paiute Ridge, Jangle Ridge, Carbonate Ridge, Slanted Buttes, Cockeyed Ridge, and Banded Mountain. The Area 3 RWMS is located on coalescing alluvial fans emanating from this drainage area.« less
NASA Technical Reports Server (NTRS)
Sprowls, D. O.
1984-01-01
A review of the literature is presented with the objectives of identifying relationships between various accelerated stress corrosion testing techniques, and for determining the combination of test methods best suited to selection and design of high strength aluminum alloys. The following areas are reviewed: status of stress-corrosion test standards, the influence of mechanical and environmental factors on stress corrosion testing, correlation of accelerated test data with in-service experience, and procedures used to avoid stress corrosion problems in service. Promising areas for further work are identified.
GIS modeling of archaeological site locations: A low-tech approach
NASA Technical Reports Server (NTRS)
Futato, Eugene M.
1991-01-01
A Geographic Information System (GIS)-type analysis of archaeological site locations using a dBase III plus program and a desk top computer is presented. A previously developed model of site locations in the Sequatchie Valley of northeastern Alabama is tested against known site locations in another large survey area there. The model fails to account for site locations in the test area. A model is developed for the test area and indicates the site locations are indeed different. Whether this is due to differences in site locations on a sub-regional level, or to sample error in the original model is unknown.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
Volume VIII of the documentation for the Phase I Data Analysis Task performed in support of the current Regional Flow Model, Transport Model, and Risk Assessment for the Nevada Test Site Underground Test Area Subproject contains the risk assessment documentation. Because of the size and complexity of the model area, a considerable quantity of data was collected and analyzed in support of the modeling efforts. The data analysis task was consequently broken into eight subtasks, and descriptions of each subtask's activities are contained in one of the eight volumes that comprise the Phase I Data Analysis Documentation.
The Effect of Pile-Up and Contact Area on Hardness Test by Nanoindentation
NASA Astrophysics Data System (ADS)
Miyake, Koji; Fujisawa, Satoru; Korenaga, Atsushi; Ishida, Takao; Sasaki, Shinya
2004-07-01
We used atomic force microscopy (AFM) for the indentation test evaluating the indentation hardness of materials in the nanometer range. BK7, fused silica, and single-crystal silicon were used as test sample materials. The data analysis processes used to determine the contact area were important in evaluating the indentation hardness of the materials. The direct measurement of the size of the residual hardness impression was useful in evaluating the contact area even in the nanometer region. The results led us to conclude that AFM indentation using a sharp indenter is a powerful method for estimating the indentation hardness in the nanometer range.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
Volume VII of the documentation for the Phase I Data Analysis Task performed in support of the current Regional Flow Model, Transport Model, and Risk Assessment for the Nevada Test Site Underground Test Area Subproject contains the tritium transport model documentation. Because of the size and complexity of the model area, a considerable quantity of data was collected and analyzed in support of the modeling efforts. The data analysis task was consequently broken into eight subtasks, and descriptions of each subtask's activities are contained in one of the eight volumes that comprise the Phase I Data Analysis Documentation.
NASA Technical Reports Server (NTRS)
Podwysocki, M. H.
1976-01-01
A study was made of the field size distributions for LACIE test sites 5029, 5033, and 5039, People's Republic of China. Field lengths and widths were measured from LANDSAT imagery, and field area was statistically modeled. Field size parameters have log-normal or Poisson frequency distributions. These were normalized to the Gaussian distribution and theoretical population curves were made. When compared to fields in other areas of the same country measured in the previous study, field lengths and widths in the three LACIE test sites were 2 to 3 times smaller and areas were smaller by an order of magnitude.
TRITIUM LABORATORY, TRA666, INTERIOR. MAIN FLOOR. CONTROL ROOM ENCLOSURE AT ...
TRITIUM LABORATORY, TRA-666, INTERIOR. MAIN FLOOR. CONTROL ROOM ENCLOSURE AT CENTER OF VIEW. SIGN ABOVE DOOR SAYS "HYDRAULIC TEST FACILITY CONTROL ROOM." SIGN IN WINDOW SAYS "EATING AREA." "EVACUATION AND EMERGENCY INFORMATION" IS POSTED ON CABINET AT LEFT OF VIEW. INL NEGATIVE NO. HD30-2-3. Mike Crane, Photographer, 6/2001 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
LPT. Shield test facility (TAN645 and 646). Sections show relationships ...
LPT. Shield test facility (TAN-645 and -646). Sections show relationships among control rooms, coupling station, counting rooms, pools, equipment rooms, data room and other areas. Ralph M. Parsons 1229-17 ANP/GE-6-645-A-4. April 1957. Approved by INEEL Classification Office for public release. INEEL index code no. 037-0645/0646-00-693-107350 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
Leak test adapter for containers
Hallett, Brian H.; Hartley, Michael S.
1996-01-01
An adapter is provided for facilitating the charging of containers and leak testing penetration areas. The adapter comprises an adapter body and stem which are secured to the container's penetration areas. The container is then pressurized with a tracer gas. Manipulating the adapter stem installs a penetration plug allowing the adapter to be removed and the penetration to be leak tested with a mass spectrometer. Additionally, a method is provided for using the adapter.
Evolution of Ada technology in the flight dynamics area: Implementation/testing phase analysis
NASA Technical Reports Server (NTRS)
Quimby, Kelvin L.; Esker, Linda; Miller, John; Smith, Laurie; Stark, Mike; Mcgarry, Frank
1989-01-01
An analysis is presented of the software engineering issues related to the use of Ada for the implementation and system testing phases of four Ada projects developed in the flight dynamics area. These projects reflect an evolving understanding of more effective use of Ada features. In addition, the testing methodology used on these projects has changed substantially from that used on previous FORTRAN projects.
Puszta, András; Katona, Xénia; Bodosi, Balázs; Pertich, Ákos; Nyujtó, Diána; Braunitzer, Gábor; Nagy, Attila
2018-01-01
The computer-based Rutgers Acquired Equivalence test (RAET) is a widely used paradigm to test the function of subcortical structures in visual associative learning. The test consists of an acquisition (pair learning) and a test (rule transfer) phase, associated with the function of the basal ganglia and the hippocampi, respectively. Obviously, such a complex task also requires cortical involvement. To investigate the activity of different cortical areas during this test, 64-channel EEG recordings were recorded in 24 healthy volunteers. Fast-Fourier and Morlet wavelet convolution analyses were performed on the recordings. The most robust power changes were observed in the theta (4–7 Hz) and gamma (>30 Hz) frequency bands, in which significant power elevation was observed in the vast majority of the subjects, over the parieto-occipital and temporo-parietal areas during the acquisition phase. The involvement of the frontal areas in the acquisition phase was remarkably weaker. No remarkable cortical power elevations were found in the test phase. In fact, the power of the alpha and beta bands was significantly decreased over the parietooccipital areas. We conclude that the initial acquisition of the image pairs requires strong cortical involvement, but once the pairs have been learned, neither retrieval nor generalization requires strong cortical contribution. PMID:29867412
Puszta, András; Katona, Xénia; Bodosi, Balázs; Pertich, Ákos; Nyujtó, Diána; Braunitzer, Gábor; Nagy, Attila
2018-01-01
The computer-based Rutgers Acquired Equivalence test (RAET) is a widely used paradigm to test the function of subcortical structures in visual associative learning. The test consists of an acquisition (pair learning) and a test (rule transfer) phase, associated with the function of the basal ganglia and the hippocampi, respectively. Obviously, such a complex task also requires cortical involvement. To investigate the activity of different cortical areas during this test, 64-channel EEG recordings were recorded in 24 healthy volunteers. Fast-Fourier and Morlet wavelet convolution analyses were performed on the recordings. The most robust power changes were observed in the theta (4-7 Hz) and gamma (>30 Hz) frequency bands, in which significant power elevation was observed in the vast majority of the subjects, over the parieto-occipital and temporo-parietal areas during the acquisition phase. The involvement of the frontal areas in the acquisition phase was remarkably weaker. No remarkable cortical power elevations were found in the test phase. In fact, the power of the alpha and beta bands was significantly decreased over the parietooccipital areas. We conclude that the initial acquisition of the image pairs requires strong cortical involvement, but once the pairs have been learned, neither retrieval nor generalization requires strong cortical contribution.
Eugenics and Mandatory Informed Prenatal Genetic Testing: A Unique Perspective from China.
Zhang, Di; Ng, Vincent H; Wang, Zhaochen; Zhai, Xiaomei; Lie, Reidar K
2016-08-01
The application of genetic technologies in China, especially in the area of prenatal genetic testing, is rapidly increasing in China. In the wealthy regions of China, prenatal genetic testing is already very widely adopted. We argue that the government should actively promote prenatal genetic testing to the poor areas of the country. In fact, the government should prioritize resources first to make prenatal genetic testing a standard routine care with an opt-out model in these area. Healthcare professions would be required to inform pregnant women about the availability of genetic testing and provide free testing on a routine basis unless the parents choose not to do so. We argue that this proposal will allow parents to make a more informed decision about their reproductive choices. Secondarily, this proposal will attract more healthcare professionals and other healthcare resources to improve the healthcare infrastructures in the less-developed regions of the country. This will help to reduce the inequity of accessing healthcare services between in different regions of China. We further argue that this policy proposal is not practicing eugenics. © 2015 John Wiley & Sons Ltd.
Endurance Test and Evaluation of Alkaline Water Electrolysis Cells
NASA Technical Reports Server (NTRS)
Kovach, Andrew J.; Schubert, Franz H.; Chang, B. J.; Larkins, Jim T.
1985-01-01
The overall objective of this program is to assess the state of alkaline water electrolysis cell technology and its potential as part of a Regenerative Fuel Cell System (RFCS) of a multikilowatt orbiting powerplant. The program evaluates the endurance capabilities of alkaline electrolyte water electrolysis cells under various operating conditions, including constant condition testing, cyclic testing and high pressure testing. The RFCS demanded the scale-up of existing cell hardware from 0.1 sq ft active electrode area to 1.0 sq ft active electrode area. A single water electrolysis cell and two six-cell modules of 1.0 sq ft active electrode area were designed and fabricated. The two six-cell 1.0 sq ft modules incorporate 1.0 sq ft utilized cores, which allow for minimization of module assembly complexity and increased tolerance to pressure differential. A water electrolysis subsystem was designed and fabricated to allow testing of the six-cell modules. After completing checkout, shakedown, design verification and parametric testing, a module was incorporated into the Regenerative Fuel Cell System Breadboard (RFCSB) for testing at Life Systems, Inc., and at NASA JSC.
Failure mechanics in low-velocity impacts on thin composite plates
NASA Technical Reports Server (NTRS)
Elber, W.
1983-01-01
Eight-ply quasi-isotropic composite plates of Thornel 300 graphite in Narmco 5208 epoxy resin (T300/5208) were tested to establish the degree of equivalence between low-velocity impact and static testing. Both the deformation and failure mechanics under impact were representable by static indentation tests. Under low-velocity impacts such as tool drops, the dominant deformation mode of the plates was the first, or static, mode. Higher modes are excited on contact, but they decay significantly by the time the first-mode load reaches a maximum. The delamination patterns were observed by X-ray analysis. The areas of maximum delamination patterns were observed by X-ray analysis. The areas of maximum delamination coincided with the areas of highest peel stresses. The extent of delamination was similar for static and impact tests. Fiber failure damage was established by tensile tests on small fiber bundles obtained by deplying test specimens. The onset of fiber damage was in internal plies near the lower surface of the plates. The distribution and amount of fiber damage was similar fo impact and static tests.
The influence of test mode and visuospatial ability on mathematics assessment performance
NASA Astrophysics Data System (ADS)
Logan, Tracy
2015-12-01
Mathematics assessment and testing are increasingly situated within digital environments with international tests moving to computer-based testing in the near future. This paper reports on a secondary data analysis which explored the influence the mode of assessment—computer-based (CBT) and pencil-and-paper based (PPT)—and visuospatial ability had on students' mathematics test performance. Data from 804 grade 6 Singaporean students were analysed using the knowledge discovery in data design. The results revealed statistically significant differences between performance on CBT and PPT test modes across content areas concerning whole number algebraic patterns and data and chance. However, there were no performance differences for content areas related to spatial arrangements geometric measurement or other number. There were also statistically significant differences in performance between those students who possess higher levels of visuospatial ability compared to those with lower levels across all six content areas. Implications include careful consideration for the comparability of CBT and PPT testing and the need for increased attention to the role of visuospatial reasoning in student's mathematics reasoning.
U.S. National Committee proposed revision to the ISO Laser Damage Standard
NASA Astrophysics Data System (ADS)
Arenberg, Jonathan W.; Howland, Donna; Thomas, Michael; Turner, Trey; Bellum, John; Field, Ella; Carr, C. Wren; Shaffer, Gary; Brophy, Matthew; Krisiloff, Allen
2017-11-01
This paper reports on the fundamental idea behind a US National Committee, The Optics and Electro-Optics Standards Council (OEOSC) Task Force (TF) 7, proposal for a so-called Type 1 laser damage test procedure. A Type 1 test is designed to give a simple binary, pass or fail, result. Such tests are intended for the transactional type of damage testing typical of acceptance and quality control testing. As such is it intended for bulk of certification of optics for the ability to survive a given fluence, useful for manufacturers of optics and their customers, the system builders. At the root of the proposed method is the probability that an optic of area A will have R or less damage occurrences with a user specified probability P at test fluence Φ. This assessment is made by a survey of area and the observation of n events. The paper presents the derivation of probability of N or less damage sites on A given n events observed in area a. The paper concludes with the remaining steps to development of a useful test procedure based on the idea presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spane, Frank A.; Newcomer, Darrell R.
2010-06-15
This report presents test descriptions and analysis results for multiple, stress-level slug tests that were performed at selected test/depth intervals within three Operable Unit (OU) UP-1 wells: 299-W19-48 (C4300/Well K), 699-30-66 (C4298/Well R), and 699-36-70B (C4299/Well P). These wells are located within, adjacent to, and to the southeast of the Hanford Site 200-West Area. The test intervals were characterized as the individual boreholes were advanced to their final drill depths. The primary objective of the hydrologic tests was to provide information pertaining to the areal variability and vertical distribution of hydraulic conductivity with depth at these locations within the OUmore » UP-1 area. This type of characterization information is important for predicting/simulating contaminant migration (i.e., numerical flow/transport modeling) and designing proper monitor well strategies for OU and Waste Management Area locations.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spane, Frank A.; Newcomer, Darrell R.
2010-06-21
The following report presents test descriptions and analysis results for multiple, stress level slug tests that were performed at selected test/depth intervals within three Operable Unit (OU) ZP-1 wells: 299-W11-43 (C4694/Well H), 299-W15-50 (C4302/Well E), and 299-W18-16 (C4303/Well D). These wells are located within south-central region of the Hanford Site 200-West Area (Figure 1.1). The test intervals were characterized as the individual boreholes were advanced to their final drill depths. The primary objective of the hydrologic tests was to provide information pertaining to the areal variability and vertical distribution of hydraulic conductivity with depth at these locations within the OUmore » ZP-1 area. This type of characterization information is important for predicting/simulating contaminant migration (i.e., numerical flow/transport modeling) and designing proper monitor well strategies for OU and Waste Management Area locations.« less
5. INSTRUMENT ROOM INTERIOR, SHOWING BACKS OF CONSOLE LOCKERS. Looking ...
5. INSTRUMENT ROOM INTERIOR, SHOWING BACKS OF CONSOLE LOCKERS. Looking northeast to firing control room passageway. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Firing Control Building, Test Area 1-100, northeast end of Test Area 1-100 Road, Boron, Kern County, CA
3. NORTHEAST REAR, SHOWING CONCRETE ENCASEMENT FOR STAIRWAY LEADING FROM ...
3. NORTHEAST REAR, SHOWING CONCRETE ENCASEMENT FOR STAIRWAY LEADING FROM INSTRUMENT ROOM TO UNDERGROUND FIRING CONTROL ROOM. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Firing Control Building, Test Area 1-100, northeast end of Test Area 1-100 Road, Boron, Kern County, CA
12. "SITE PLAN." Test Area 1100. Specifications No. OC35973; Drawing ...
12. "SITE PLAN." Test Area 1-100. Specifications No. OC359-73; Drawing No. 5841-C-1; D.O. SERIES AW1525/7 Rev. A. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Leuhman Ridge near Highways 58 & 395, Boron, Kern County, CA
Preliminary report on engineering geology of thirteen tunnel sites, Nevada Test Site
Wilmarth, Verl Richard; McKeown, Francis Alexander; Dobrovolny, Ernest
1958-01-01
Reconnaissance of 13 areas in and adjacent to Nevada Test Site was completed. Of the 13 areas, Forty Mile Canyon, South-central Shoshone Mountain, and Southeast Shoshone Mountain named in order of preference, offer many advantages for carrying on future underground nuclear explosions.
Geber, Christian; Klein, Thomas; Azad, Shahnaz; Birklein, Frank; Gierthmühlen, Janne; Huge, Volker; Lauchart, Meike; Nitzsche, Dorothee; Stengel, Maike; Valet, Michael; Baron, Ralf; Maier, Christoph; Tölle, Thomas; Treede, Rolf-Detlef
2011-03-01
Quantitative sensory testing (QST) is an instrument to assess positive and negative sensory signs, helping to identify mechanisms underlying pathologic pain conditions. In this study, we evaluated the test-retest reliability (TR-R) and the interobserver reliability (IO-R) of QST in patients with sensory disturbances of different etiologies. In 4 centres, 60 patients (37 male and 23 female, 56.4±1.9years) with lesions or diseases of the somatosensory system were included. QST comprised 13 parameters including detection and pain thresholds for thermal and mechanical stimuli. QST was performed in the clinically most affected test area and a less or unaffected control area in a morning and an afternoon session on 2 consecutive days by examiner pairs (4 QSTs/patient). For both, TR-R and IO-R, there were high correlations (r=0.80-0.93) at the affected test area, except for wind-up ratio (TR-R: r=0.67; IO-R: r=0.56) and paradoxical heat sensations (TR-R: r=0.35; IO-R: r=0.44). Mean IO-R (r=0.83, 31% unexplained variance) was slightly lower than TR-R (r=0.86, 26% unexplained variance, P<.05); the difference in variance amounted to 5%. There were no differences between study centres. In a subgroup with an unaffected control area (n=43), reliabilities were significantly better in the test area (TR-R: r=0.86; IO-R: r=0.83) than in the control area (TR-R: r=0.79; IO-R: r=0.71, each P<.01), suggesting that disease-related systematic variance enhances reliability of QST. We conclude that standardized QST performed by trained examiners is a valuable diagnostic instrument with good test-retest and interobserver reliability within 2days. With standardized training, observer bias is much lower than random variance. Quantitative sensory testing performed by trained examiners is a valuable diagnostic instrument with good interobserver and test-retest reliability for use in patients with sensory disturbances of different etiologies to help identify mechanisms of neuropathic and non-neuropathic pain. Copyright © 2010 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.
2. EAST ELEVATION OF POWER PLANT TEST STAND (HORIZONTAL TEST ...
2. EAST ELEVATION OF POWER PLANT TEST STAND (HORIZONTAL TEST STAND REMNANTS OF BUILDING-BLANK WHITE WALL ONLY ORIGINAL REMAINS. - Marshall Space Flight Center, East Test Area, Power Plant Test Stand, Huntsville, Madison County, AL
4. VIEW SOUTHWEST COMPONENTS TEST LAB TEST BAY DETAIL SHOWING ...
4. VIEW SOUTHWEST COMPONENTS TEST LAB TEST BAY DETAIL SHOWING EMERGENCY SHOWER, AND EYEWASH, AND OBSERVATION WINDOW. STORAGE TANKS ON ROOF. - Marshall Space Flight Center, East Test Area, Components Test Laboratory, Huntsville, Madison County, AL
Design of a variable area diffuser for a 15-inch Mach 6 open-jet tunnel
NASA Technical Reports Server (NTRS)
Loney, Norman W.
1994-01-01
The Langley 15-inch Mach 6 High Temperature Tunnel was recently converted from a Mach 10 Hypersonic Flow Apparatus. This conversion was effected to improve the capability of testing in Mach 6 air at relatively high reservoir temperatures not previously possible at Langley. Elevated temperatures allow the matching of the Mach numbers, Reynolds numbers, and ratio of wall-to-adiabatic-wall temperatures (TW/Taw) between this and the Langley 20-inch Mach 6 CF4 Tunnel. This ratio is also matched for Langley's 31-inch Mach 10 Tunnel and is an important parameter useful in the simulation of slender bodies such as National Aerospace Plane (NASP) configurations currently being studied. Having established the nozzle's operating characteristics, the decision was made to install another test section to provide model injection capability. This test section is an open-jet type, with an injection system capable of injecting a model from retracted position to nozzle centerline between 0.5 and 2 seconds. Preliminary calibrations with the new test section resulted in Tunnel blockage. This blockage phenomenon was eliminated when the conical center body in the diffuser was replaced. The issue then, is to provide a new and more efficient variable area diffuser configuration with the capability to withstand testing of larger models without sending the Tunnel into an unstart condition. Use of the 1-dimensional steady flow equation with due regard to friction and heat transfer was employed to estimate the required area ratios (exit area / throat area) in a variable area diffuser. Correlations between diffuser exit Mach number and area ratios, relative to the stagnation pressure ratios and diffuser inlet Mach number were derived. From these correlations, one can set upper and lower operating pressures and temperatures for a given diffuser throat area. In addition, they will provide appropriate input conditions for the full 3-dimensional computational fluid dynamics (CFD) code for further simulation studies.
Analyzing actual risk in malaria-deferred donors through selective serologic testing.
Nguyen, Megan L; Goff, Tami; Gibble, Joan; Steele, Whitney R; Leiby, David A
2013-08-01
Approximately 150,000 US blood donors are deferred annually for travel to malaria-endemic areas. However, the majority do not travel to the high-risk areas of Africa associated with transfusion-transmitted malaria (TTM) but visit low-risk areas such as Mexico. This study tests for Plasmodium infection among malaria-deferred donors, particularly those visiting Mexico. Blood donors deferred for malaria risk (travel, residence, or previous infection) provided blood samples and completed a questionnaire. Plasma was tested for Plasmodium antibodies by enzyme immunoassay (EIA); repeat-reactive (RR) samples were considered positive and tested by real-time polymerase chain reaction (PCR). Accepted donors provided background testing data. During 2005 to 2011, a total of 5610 malaria-deferred donors were tested by EIA, including 5412 travel deferrals. Overall, 88 (1.6%) were EIA RR; none were PCR positive. Forty-nine (55.7%) RR donors previously had malaria irrespective of deferral category, including 34 deferred for travel. Among 1121 travelers to Mexico, 90% visited Quintana Roo (no or very low risk), but just 2.2% visited Oaxaca/Chiapas (moderate or high risk). Only two Mexican travelers tested RR; both previously had malaria not acquired in Mexico. Travel to Mexico represents a large percentage of US donors deferred for malaria risk; however, these donors primarily visit no- or very-low-risk areas. No malaria cases acquired in Mexico were identified thereby supporting previous risk estimates. Consideration should be given to allowing blood donations from U.S. donors who travel to Quintana Roo and other low-risk areas in Mexico. A more effective approach to preventing TTM would be to defer all donors with a history of malaria, even if remote. © 2012 American Association of Blood Banks.
18. STATIC TEST TOWER VIEW FROM REMOVABLE LEVEL DOWN ...
18. STATIC TEST TOWER - VIEW FROM REMOVABLE LEVEL DOWN TOWARDS GANTRY CRANE AND THREE TEST CELLS. - Marshall Space Flight Center, Saturn Propulsion & Structural Test Facility, East Test Area, Huntsville, Madison County, AL
Hydrogeology and water quality in the Graces Quarters area of Aberdeen Proving Ground, Maryland
Tenbus, Frederick J.; Blomquist, Joel D.
1995-01-01
Graces Quarters was used for open-air testing of chemical-warfare agents from the late 1940's until 1971. Testing and disposal activities have resulted in the contamination of ground water and surface water. The hydrogeology and water quality were examined at three test areas, four disposal sites, a bunker, and a service area on Graces Quarters. Methods of investigation included surface and borehole geophysics, water-quality sampling, water- level measurement, and hydrologic testing. The hydrogeologic framework is complex and consists of a discontinuous surficial aquifer, one or more upper confining units, and a confined aquifer system. Directions of ground-water flow vary spatially and temporally, and results of site investigations show that ground-water flow is controlled by the geology of the area. The ground water and surface water at Graces Quarters generally are unmineralized; the ground water is mildly acidic (median pH is 5.38) and poorly buffered. Inorganic constituents in excess of certain Federal drinking-water regulations and ambient water-quality criteria were detected at some sites, but they probably were present naturally. Volatile and semivolatile organic com- pounds were detected in the ground water and surface water at seven of the nine sites that were investi- gated. Concentrations of organic compounds at two of the nine sites exceeded Federal drinking-water regulations. Volatile compounds in concentrations as high as 6,000 m/L (micrograms per liter) were detected in the ground water at the site known as the primary test area. Concentrations of volatile compounds detected in the other areas ranged from 0.57 to 17 m/L.
The impact of surface area, volume, curvature, and Lennard-Jones potential to solvation modeling.
Nguyen, Duc D; Wei, Guo-Wei
2017-01-05
This article explores the impact of surface area, volume, curvature, and Lennard-Jones (LJ) potential on solvation free energy predictions. Rigidity surfaces are utilized to generate robust analytical expressions for maximum, minimum, mean, and Gaussian curvatures of solvent-solute interfaces, and define a generalized Poisson-Boltzmann (GPB) equation with a smooth dielectric profile. Extensive correlation analysis is performed to examine the linear dependence of surface area, surface enclosed volume, maximum curvature, minimum curvature, mean curvature, and Gaussian curvature for solvation modeling. It is found that surface area and surfaces enclosed volumes are highly correlated to each other's, and poorly correlated to various curvatures for six test sets of molecules. Different curvatures are weakly correlated to each other for six test sets of molecules, but are strongly correlated to each other within each test set of molecules. Based on correlation analysis, we construct twenty six nontrivial nonpolar solvation models. Our numerical results reveal that the LJ potential plays a vital role in nonpolar solvation modeling, especially for molecules involving strong van der Waals interactions. It is found that curvatures are at least as important as surface area or surface enclosed volume in nonpolar solvation modeling. In conjugation with the GPB model, various curvature-based nonpolar solvation models are shown to offer some of the best solvation free energy predictions for a wide range of test sets. For example, root mean square errors from a model constituting surface area, volume, mean curvature, and LJ potential are less than 0.42 kcal/mol for all test sets. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
105KE Basin Area Radiation Monitor System (ARMS) Acceptance Test Procedure
DOE Office of Scientific and Technical Information (OSTI.GOV)
KINKEL, C.C.
1999-12-14
This procedure is intended for the Area Radiation Monitoring System, ARMS, that is replacing the existing Programmable Input-Output Processing System, PIOPS, radiation monitoring system in the 105KE basin. The new system will be referred to as the 105KE ARMS, 105KE Area Radiation Monitoring System. This ATP will ensure calibration integrity of the 105KE radiation detector loops. Also, this ATP will test and document the display, printing, alarm output, alarm acknowledgement, upscale check, and security functions. This ATP test is to be performed after completion of the 105KE ARMS installation. The alarm outputs of the 105KE ARMS will be connected tomore » the basin detector alarms, basin annunciator system, and security Alarm Monitoring System, AMS, located in the 200 area Central Alarm Station (CAS).« less
Variable area radial turbine fabrication and test program
NASA Technical Reports Server (NTRS)
Rogo, C.
1986-01-01
A variable area radial turbine with a moveable nozzle sidewall was experimentally evaluated. The turbine was designed for an advanced variable capacity gas turbine rotorcraft engine. The turbine has a mass flow rate of 2.27 kg/sec (5.0 lbs/sec), and a rotor inlet temperature of 1477K (2200 F). Testing was conducted at a reduced inlet temperature, but the aerodynamic parameters and Reynolds numbers were duplicated. Overall performance was obtained for a range of nozzle areas from 50% to 100% of the maximum area. The test program determined the effect on performance of: (1) Moving the hub or shroud sidewall; (2) Sidewall-vane clearance leakage; (3) Vaneless space geometry change; and (4) Nozzle cooling flows. Data were obtained for a range of pressure ratios and speeds and are presented in a number of performance maps.
Experimental performance of a high-area-ratio rocket nozzle at high combustion chamber pressure
NASA Technical Reports Server (NTRS)
Jankovsky, Robert S.; Kazaroff, John M.; Pavli, Albert J.
1996-01-01
An experimental investigation was conducted to determine the thrust coefficient of a high-area-ratio rocket nozzle at combustion chamber pressures of 12.4 to 16.5 MPa (1800 to 2400 psia). A nozzle with a modified Rao contour and an expansion area ratio of 1025:1 was tested with hydrogen and oxygen at altitude conditions. The same nozzle, truncated to an area ratio of 440:1, was also tested. Values of thrust coefficient are presented along with characteristic exhaust velocity efficiencies, nozzle wall temperatures, and overall thruster specific impulse.
Examination of Spectral Transformations on Spectral Mixture Analysis
NASA Astrophysics Data System (ADS)
Deng, Y.; Wu, C.
2018-04-01
While many spectral transformation techniques have been applied on spectral mixture analysis (SMA), few study examined their necessity and applicability. This paper focused on exploring the difference between spectrally transformed schemes and untransformed scheme to find out which transformed scheme performed better in SMA. In particular, nine spectrally transformed schemes as well as untransformed scheme were examined in two study areas. Each transformed scheme was tested 100 times using different endmember classes' spectra under the endmember model of vegetation- high albedo impervious surface area-low albedo impervious surface area-soil (V-ISAh-ISAl-S). Performance of each scheme was assessed based on mean absolute error (MAE). Statistical analysis technique, Paired-Samples T test, was applied to test the significance of mean MAEs' difference between transformed and untransformed schemes. Results demonstrated that only NSMA could exceed the untransformed scheme in all study areas. Some transformed schemes showed unstable performance since they outperformed the untransformed scheme in one area but weakened the SMA result in another region.
A principal activity of the Offsite Radiological Safety Program is routine environmental monitoring for radioactive materials in various media and for radiation in areas which may be affected by nuclear tests. It is conducted to document compliance with standards, to identify tre...
2. AERIAL VIEW OF MINUTEMAN SILOS. Low oblique aerial view ...
2. AERIAL VIEW OF MINUTEMAN SILOS. Low oblique aerial view (original in color) of the two launch silos, covered. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Missile Silo Type, Test Area 1-100, northeast end of Test Area 1-100 Road, Boron, Kern County, CA
MTR WING, TRA604, INTERIOR. BASEMENT. WEST CORRIDOR. CAMERA FACES NORTH. ...
MTR WING, TRA-604, INTERIOR. BASEMENT. WEST CORRIDOR. CAMERA FACES NORTH. HVAC AREA IS AT RIGHT OF CORRIDOR. INL NEGATIVE NO. HD46-13-3. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
10 CFR 60.44 - Changes, tests, and experiments.
Code of Federal Regulations, 2010 CFR
2010-01-01
... REPOSITORIES Licenses License Issuance and Amendment § 60.44 Changes, tests, and experiments. (a)(1) Following authorization to receive and possess source, special nuclear, or byproduct material at a geologic repository operations area, the DOE may (i) make changes in the geologic repository operations area as described in the...
Take a Tour of Our Facility | Energy Systems Integration Facility | NREL
Take a Tour of Our Facility Take a Tour of Our Facility The Energy Systems Integration Facility Optical Characterization Laboratory System Performance Laboratory Power Systems Integration Laboratory Control Room Energy Storage Laboratory Outdoor Testing Areas Outdoor Testing Areas Energy Systems
10 CFR 60.131 - General design criteria for the geologic repository operations area.
Code of Federal Regulations, 2012 CFR
2012-01-01
... operating systems, including alarm systems, important to safety. (g) Inspection, testing, and maintenance... radioactivity areas; and (6) A radiation alarm system to warn of significant increases in radiation levels... system shall be designed with provisions for calibration and for testing its operability. (b) Protection...
10 CFR 60.131 - General design criteria for the geologic repository operations area.
Code of Federal Regulations, 2014 CFR
2014-01-01
... operating systems, including alarm systems, important to safety. (g) Inspection, testing, and maintenance... radioactivity areas; and (6) A radiation alarm system to warn of significant increases in radiation levels... system shall be designed with provisions for calibration and for testing its operability. (b) Protection...
10 CFR 60.131 - General design criteria for the geologic repository operations area.
Code of Federal Regulations, 2011 CFR
2011-01-01
... operating systems, including alarm systems, important to safety. (g) Inspection, testing, and maintenance... radioactivity areas; and (6) A radiation alarm system to warn of significant increases in radiation levels... system shall be designed with provisions for calibration and for testing its operability. (b) Protection...
10 CFR 60.131 - General design criteria for the geologic repository operations area.
Code of Federal Regulations, 2013 CFR
2013-01-01
... operating systems, including alarm systems, important to safety. (g) Inspection, testing, and maintenance... radioactivity areas; and (6) A radiation alarm system to warn of significant increases in radiation levels... system shall be designed with provisions for calibration and for testing its operability. (b) Protection...
This report covers the routine radiation monitoring activities conducted by the Environmental Monitoring Systems Laboratory-Las Vegas in areas which may be affected by nuclear testing programs of the Department of Energy. This monitoring is conducted to document compliance with s...
This report covers the routine radiation monitoring activities conducted by the Environmental Monitoring Systems Laboratory-Las Vegas in areas which may be affected by nuclear testing programs of the Department of Energy. This monitoring is conducted to document compliance with s...
This report covers the routine radiation monitoring activities conducted by the Environmental Monitoring Systems Laboratory-Las Vegas in areas which may be affected by nuclear testing programs of the Department of Energy. This monitoring is conducted to document compliance with s...
ETR, TRA642. BENCH MARK AND ELEVATION LOCATIONS, FLOOR LOADING DATA, ...
ETR, TRA-642. BENCH MARK AND ELEVATION LOCATIONS, FLOOR LOADING DATA, CRANE WORKING AREAS. PHILLIPS PETROLEUM COMPANY ETR-D-1584, 5/1959. INL INDEX NO. 532-0642-00-706-020323, REV. 3. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Beliefs about chlamydia testing amongst young people living in relatively deprived areas.
Booth, A R; Harris, P R; Goyder, E; Norman, P
2013-06-01
This study uses the theory of planned behaviour (TPB) as a framework to investigate salient beliefs about chlamydia testing, amongst young people living in relatively deprived areas. These beliefs may form targets for intervention to increase testing in this high-risk population. Participants recruited from colleges in deprived areas of a UK city, completed open-ended questions designed to elicit salient beliefs. Responses were content analysed and categorized as describing behavioural, normative or control beliefs. Beliefs were elicited from 128 respondents (51% male; median age = 17). The commonest behavioural belief, which could have a positive or negative impact on screening intentions, was that testing provides information about health status. Partners were referred to most commonly amongst the normative beliefs. Practical aspects and concerns about social implications of testing were common control beliefs. References to several negative emotions emerged throughout. This study indicates that raising awareness of chlamydia as a serious sexual health problem may not be the best way to increase the uptake of testing in a high-risk population. Promoting chlamydia testing as potentially providing reassurance may be an alternative. It may also be important to reduce perceptions of social disapproval as well as negative emotion regarding chlamydia testing.
Testing the ability of a semidistributed hydrological model to simulate contributing area
NASA Astrophysics Data System (ADS)
Mengistu, S. G.; Spence, C.
2016-06-01
A dry climate, the prevalence of small depressions, and the lack of a well-developed drainage network are characteristics of environments with extremely variable contributing areas to runoff. These types of regions arguably present the greatest challenge to properly understanding catchment streamflow generation processes. Previous studies have shown that contributing area dynamics are important for streamflow response, but the nature of the relationship between the two is not typically understood. Furthermore, it is not often tested how well hydrological models simulate contributing area. In this study, the ability of a semidistributed hydrological model, the PDMROF configuration of Environment Canada's MESH model, was tested to determine if it could simulate contributing area. The study focused on the St. Denis Creek watershed in central Saskatchewan, Canada, which with its considerable topographic depressions, exhibits wide variation in contributing area, making it ideal for this type of investigation. MESH-PDMROF was able to replicate contributing area derived independently from satellite imagery. Daily model simulations revealed a hysteretic relationship between contributing area and streamflow not apparent from the less frequent remote sensing observations. This exercise revealed that contributing area extent can be simulated by a semi-distributed hydrological model with a scheme that assumes storage capacity distribution can be represented with a probability function. However, further investigation is needed to determine if it can adequately represent the complex relationship between streamflow and contributing area that is such a key signature of catchment behavior.
2013-09-01
Ground testing of prototype hardware and processing algorithms for a Wide Area Space Surveillance System (WASSS) Neil Goldstein, Rainer A...at Magdalena Ridge Observatory using the prototype Wide Area Space Surveillance System (WASSS) camera, which has a 4 x 60 field-of-view , < 0.05...objects with larger-aperture cameras. The sensitivity of the system depends on multi-frame averaging and a Principal Component Analysis based image
2006-10-16
spawning sites, feeding sites, 20 seasonal wetlands or drylands, water quality or quantity, host species or plant pollinators , geological 21...rufus]). 12 These areas also contain relatively large areas of sensitive plants . 13 3.9.2.9 Significant Ecological Areas found within the R-2515 and...for complete aircraft, avionics systems, and integrated 21 airframe weapons support. Thus, HPM testing would continue the evolution of the primary
Clinical and Epidemiological Studies on Rickettsial Infections
1978-10-01
musculus in areas of Lebanon, Pakistan, Australia, Sarawak and Baltimore are treated in :1 Table 8. NUMB3ER NIUMBER % HOST AREA POSITIVE TESTED PCO’ITIVE... Sarawak : rattus Kuching 19 39 49% (Sops) Rattus Sarawak : r attus Kuching 0 13 - (Residential) 2 Rattus (Others) Sarawak - I Mus Kuching 0 3...Kuching, Sarawak . Interestingly, none of the 16 rats from residential areas in Kuch- ing were infected. In IFA tests on 79 human sera from Nepal, 6
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sloop, Christy
2013-04-01
This Corrective Action Decision Document/Closure Report presents information supporting the closure of Corrective Action Unit (CAU) 569: Area 3 Yucca Flat Atmospheric Test Sites, Nevada National Security Site, Nevada. CAU 569 comprises the following nine corrective action sites (CASs): • 03-23-09, T-3 Contamination Area • 03-23-10, T-3A Contamination Area • 03-23-11, T-3B Contamination Area • 03-23-12, T-3S Contamination Area • 03-23-13, T-3T Contamination Area • 03-23-14, T-3V Contamination Area • 03-23-15, S-3G Contamination Area • 03-23-16, S-3H Contamination Area • 03-23-21, Pike Contamination Area The purpose of this Corrective Action Decision Document/Closure Report is to provide justification and documentation supportingmore » the recommendation that no further corrective action is needed for CAU 569 based on the implementation of the corrective actions listed in Table ES-2.« less
Improved Testing Capability and Adaptability Through the Use of Wireless Sensors
NASA Technical Reports Server (NTRS)
Solano, Wanda M.
2003-01-01
From the first Saturn V rocket booster (S-II-T) testing in 1966 and the routine Space Shuttle Main Engine (SSME) testing beginning in 1975, to more recent test programs such as the X-33 Aerospike Engine, the Integrated Powerhead Development (IPD) program, and the Hybrid Sounding Rocket (HYSR), Stennis Space Center (SSC) continues to be a premier location for conducting large-scale testing. Central to each test program is the capability for sensor systems to deliver reliable measurements and high quality data, while also providing a means to monitor the test stand area to the highest degree of safety and sustainability. Sensor wiring is routed along piping and through cable trenches, making its way from the engine test area, through the test stand area and to the signal conditioning building before final transfer to the test control center. When sensor requirements lie outside the reach of the routine sensor cable routing, the use of wireless sensor networks becomes particularly attractive due to their versatility and ease of installation. As part of an on-going effort to enhance the testing capabilities of Stennis Space Center, the Test Technology and Development group has found numerous applications for its sensor-adaptable wireless sensor suite. While not intended for critical engine measurements or control loops, in-house hardware and software development of the sensor suite can provide improved testing capability for a range of applications including the safety monitoring of propellant storage barrels and as an experimental test-bed for embedded health monitoring paradigms.
Viscoelastic Properties of Advanced Polymer Composites for Ballistic Protective Applications
1994-09-01
ofthe Damaged Sample 78 Figure 69: Fracture Surface of Damage Area Near the Point of Penetration 79 Figure 70. Closer View ofthe Damaged Area...LIST OF TABLES Table 1. Basic Mechanical Properties of the Materials 6 Table 2. Initial DMA Test Results 23 Table 3. Flexural Three Point Bend... point bend testing was conducted using an Instron 1127 Universal Tester to verify the DMA test method and specimen clamping configuration. Interfacial
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-08
...Pursuant to section 102(2)(c) of the National Environmental Policy Act of 1969, as implemented by the Council on Environmental Quality Regulations (40 Code of Federal Regulations parts 1500-1508), and Executive Order 12114, the Department of the Navy (DoN) announces its intent to prepare an Environmental Impact Statement (EIS)/Overseas Environmental Impact Statement (OEIS) to evaluate the potential environmental effects associated with maintaining military readiness training and research, development, testing, and evaluation (hereafter referred to as ``training and testing'') activities conducted in the Mariana Islands Training and Testing (MITT) EIS/OEIS Study Area. The MITT Study Area includes the existing Mariana Islands Range Complex (MIRC), additional areas on the high seas, and a general transit corridor between Hawaii to MITT where training and testing activities may occur. The MIRC is the only major Navy range complex in the Study Area. The DoN is preparing this EIS/OEIS to renew current regulatory permits and authorizations, address current training and testing not covered under existing permits and authorizations, and to obtain those permits and authorizations necessary to support force structure changes and emerging and future training and testing requirements including those associated with new platforms and weapons systems within the MITT Study Area, starting in 2015, thereby ensuring critical Department of Defense (DoD) requirements are met. The DoN will invite the National Marine Fisheries Service, United States (U.S.) Fish and Wildlife Service (Pacific Islands Fish and Wildlife Office), and U.S. Air Force, to be cooperating agencies in preparation of the EIS/OEIS.
Marques, Ana Paula C; Oliveira, Sandra Maria V L; Rezende, Grazielli R; Melo, Dayane A; Fernandes-Fitts, Sonia M; Pontes, Elenir Rose J C; Bonecini-Almeida, Maria da Glória; Camargo, Zoilo P; Mendes, Rinaldo P; Paniago, Anamaria M M
2017-10-01
We estimated the occurrence rate of the booster phenomenon by using an intradermal test with 43 kDa glycoprotein in an endemic area of paracoccidioidomycosis in the central-west region of Brazil. Individuals who had a negative result on a survey performed by using an intradermal test with 43 kDa glycoprotein in an endemic area of paracoccidioidomycosis underwent a second intradermal test after 10-15 days to determine the presence or absence of the booster phenomenon. Statistical analyses were performed using the Chi-square test, Chi-square for linear trend test, Student's t test, and binomial test; p < 0.05 was considered significant. For the first time, we reported the occurrence of the booster phenomenon to an intradermal reaction caused by 43 kDa glycoprotein at a rate of 5.8-8.4%, depending on the test's cutoff point. This suggests that a cutoff point should be considered for the booster phenomenon in intradermal tests with 43 kDa glycoprotein: a difference of 6-7 mm between readings according to the first and second tests, depending on the purpose of the evaluation. The results indicate that the prevalence of paracoccidioidal infection in endemic areas is underestimated, as the booster phenomenon has not been considered in epidemiological surveys for this infection.
Murray, Alexander G
2014-08-01
Movements of water that transport pathogens mean that in net-pen aquaculture diseases are often most effectively managed collaboratively among neighbours. Such area management is widely and explicitly applied for pathogen management in marine salmon farms. Effective area management requires the active support of farm managers and a simple game-theory based framework was developed to identify the conditions required under which collaboration is perceived to be in their own best interest. The model applied is based on area management as practiced for Scottish salmon farms, but its simplicity allows it to be generalised to other area-managed net-pen aquaculture systems. In this model managers choose between purchasing tested pathogen-free fish or cheaper, untested fish that might carry pathogens. Perceived pay-off depends on degree of confidence that neighbours will not buy untested fish, risking input of pathogens that spread between farms. For a given level of risk, confidence in neighbours is most important in control of moderate-impact moderate-probability diseases. Common low-impact diseases require high confidence since there is a high probability a neighbour will import, while testing for rare high-impact diseases may be cost-effective regardless of neighbours actions. In some cases testing may be beneficial at an area level, even if all individual farms are better off not testing. Higher confidence is required for areas with many farms and so focusing management on smaller, epidemiologically imperfect, areas may be more effective. The confidence required for collaboration can be enhanced by the development of formal agreements and the involvement of outside disinterested parties such as trade bodies or government. Copyright © 2014. Published by Elsevier B.V.
Object-oriented classification of drumlins from digital elevation models
NASA Astrophysics Data System (ADS)
Saha, Kakoli
Drumlins are common elements of glaciated landscapes which are easily identified by their distinct morphometric characteristics including shape, length/width ratio, elongation ratio, and uniform direction. To date, most researchers have mapped drumlins by tracing contours on maps, or through on-screen digitization directly on top of hillshaded digital elevation models (DEMs). This paper seeks to utilize the unique morphometric characteristics of drumlins and investigates automated extraction of the landforms as objects from DEMs by Definiens Developer software (V.7), using the 30 m United States Geological Survey National Elevation Dataset DEM as input. The Chautauqua drumlin field in Pennsylvania and upstate New York, USA was chosen as a study area. As the study area is huge (approximately covers 2500 sq.km. of area), small test areas were selected for initial testing of the method. Individual polygons representing the drumlins were extracted from the elevation data set by automated recognition, using Definiens' Multiresolution Segmentation tool, followed by rule-based classification. Subsequently parameters such as length, width and length-width ratio, perimeter and area were measured automatically. To test the accuracy of the method, a second base map was produced by manual on-screen digitization of drumlins from topographic maps and the same morphometric parameters were extracted from the mapped landforms using Definiens Developer. Statistical comparison showed a high agreement between the two methods confirming that object-oriented classification for extraction of drumlins can be used for mapping these landforms. The proposed method represents an attempt to solve the problem by providing a generalized rule-set for mass extraction of drumlins. To check that the automated extraction process was next applied to a larger area. Results showed that the proposed method is as successful for the bigger area as it was for the smaller test areas.
Development of an evaporation-optimized and water-permeable pavement
NASA Astrophysics Data System (ADS)
Starke, P.; Göbel, P.; Coldewey, W. G.
2009-04-01
During recent decades, urban areas have been threatened more frequently by flood events. Furthermore, the potential for damage from these events has increased on average. The construction of houses, streets and parking lots has caused this trend by sealing the ground surface, i.e. these water-impermeable areas reduce the natural infiltration and evaporation-rates, and in some cases it is even completely stopped. The consequence is the so called "urban water cycle". Water from precipitation cannot be stored anywhere and so there is an immediate and very high surface run-off effect. Especially after intense rain events, canalisations and sewage-treatment plants are overloaded and this leads to higher costs for water treatment and to environmental damage. A practical solution to this problem is the use of water-permeable pavements. Here higher infiltration rates lead to a groundwater recharge that is greater than that of natural soils. The consequences from using these surfaces are already noticeable in many places through increasing groundwater levels. These increases cause damage to buildings. A second difference from a natural-soil water-balance is a lower evapotranspiration rate. Up to now the evaporation rates for water-permeable pavements has not been established accurately. The aim of the applied research project at the University of Muenster, which is sponsored by the DBU (The German Federal Environmental Foundation), is to gain knowledge of urban evaporation rates and of water-permeable surfaces, especially water-permeable pavements. Water-permeable pavements consist of the paving stone surface and the two sub-base layers below. Pre-investigations show that evaporation can be influenced by the complete sub-base. Therefore, the first step was to investigate which materials are used for sub-base construction. All in all, 27 materials were collected from throughout Germany and these materials were then tested (in terms of physical and hydraulic attributes) in the soil-mechanics laboratory of the University of Muenster. For their street construction useability, and having regard to evaporation, a selection of appropriate materials were built into a test field. The test field consisted of seven hexagonal areas each about 10 m2 large, which are placed in a honeycomb manner. The evaporation measurements are carried out with a WERNER tunnel-evaporation gauge (TUV) which is able to detect the actual evaporation rate. Its functional principle also allows a direct comparison between the middle reference area and one outer area of the test field. Every measuring period lasts one week and after that the TUV is moved to between the next outer area and the reference area. So the TUV rotates over the whole test field and every measuring area is covered by a measurement. In addition, a Hellman rain-gauge near the test field enables the measurement of a direct precipitation-evaporation ratio. Since the start of the measurements in July 2008, the first results collected showed that measureable differences in evaporation rates could be detected after a few measuring periods, i.e. the differences are up to 32% between the reference area and one outer area. In July 2009, the six outer measuring areas of the test field will be replaced and, based on the actual results collected, the sub-base layers will be replaced by an evaporation-optimized sub-base. The new outer measuring areas will only differ in terms of a different paving-stone surface. These paving stones are actually under developement and under laboratory testing (i.e. permeability, porosity, capillary water and evaporationrates), and so they will be evaporation-opimized. The open-air test in the test field is to assure and compare the evaporation rates. As a final result, the evaporation-optimized and water-permeable pavement and the knowledge of its exact drainage ratio will allow city planners or architects to build water-permeable streets with due regard to the respective area-specific conditions. This new developed pavement is an approximation to the water balance of a natural soil. In this way, the danger of flooding can be further reduced in urban areas.
24. SATURN V Fl ENGINE TEST FIRING ON TEST STAND ...
24. SATURN V F-l ENGINE TEST FIRING ON TEST STAND 1A. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA
Code of Federal Regulations, 2013 CFR
2013-01-01
... assessment area(s) through its lending activities by considering a bank's home mortgage, small business... mortgage, small business, small farm, and consumer loans, if applicable, in the bank's assessment area(s); (2) Geographic distribution. The geographic distribution of the bank's home mortgage, small business...
Code of Federal Regulations, 2011 CFR
2011-01-01
... assessment area(s) through its lending activities by considering a bank's home mortgage, small business... mortgage, small business, small farm, and consumer loans, if applicable, in the bank's assessment area(s); (2) Geographic distribution. The geographic distribution of the bank's home mortgage, small business...
Code of Federal Regulations, 2014 CFR
2014-01-01
... assessment area(s) through its lending activities by considering a bank's home mortgage, small business... mortgage, small business, small farm, and consumer loans, if applicable, in the bank's assessment area(s); (2) Geographic distribution. The geographic distribution of the bank's home mortgage, small business...
33 CFR 334.1190 - Hood Canal and Dabob Bay, Wash.; naval non-explosive torpedo testing area.
Code of Federal Regulations, 2010 CFR
2010-07-01
... CORPS OF ENGINEERS, DEPARTMENT OF THE ARMY, DEPARTMENT OF DEFENSE DANGER ZONE AND RESTRICTED AREA... the area. (iii) No vessel shall anchor in the area except between the shore and the 10-fathom depth...
33 CFR 334.1190 - Hood Canal and Dabob Bay, Wash.; naval non-explosive torpedo testing area.
Code of Federal Regulations, 2011 CFR
2011-07-01
... CORPS OF ENGINEERS, DEPARTMENT OF THE ARMY, DEPARTMENT OF DEFENSE DANGER ZONE AND RESTRICTED AREA... the area. (iii) No vessel shall anchor in the area except between the shore and the 10-fathom depth...
Bilotta, Federico; Stazi, Elisabetta; Titi, Luca; Lalli, Diana; Delfini, Roberto; Santoro, Antonio; Rosa, Giovanni
2014-06-01
Awake craniotomy is the technique of choice in patients with brain tumours adjacent to primary and accessory language areas (Broca's and Wernicke's areas). Language testing should be aimed to detect preoperative deficits, to promptly identify the occurrence of new intraoperative impairments and to establish the course of postoperative language status. Aim of this case series is to describe our experience with a dedicated language testing work up to evaluate patients with or at risk for language disturbances undergoing awake craniotomy for brain tumour resection. Pre- and intra operative testing was accomplished with 8 tests. Intraoperative evaluation was accomplished when patients were fully cooperative (Ramsey < 3). Postoperative evaluation was scheduled at early (within 21 days) and long-term follow-up (3-6 months). Twenty consecutive patients were prospectively recruited. Preoperative language testings were normal in 9 patients (45%), showed mild to moderate language deficit in 8 (40%) and severe language deficit or aphasic disorders in 3 (15%). Broca's area was identified in 15 patients, in all cases by counting arrest during stimulation and in 12 cases by naming arrest. In this article we describe our experience using a language testing work up to evaluate - pre, intra and postoperatively - patients undergoing awake craniotomy for brain tumour resection with preoperative language disturbances or at risk for postoperative language deficits. This approach allows a systematic evaluation and recording of language function status and can be accomplished even when a neuropsychologist or speech therapist are not involved in the operation crew.
Ryberg, Karen R.
2007-01-01
The Oakes Test Area is operated and maintained by the Garrison Diversion Conservancy District, under a cooperative agreement with the Bureau of Reclamation, to evaluate the effectiveness and environmental consequences of irrigation. As part of the evaluation, the Bureau of Reclamation collected water-quality samples from seven sites on the James River and the Oakes Test Area. The data were summarized and examined for trends in concentration. A nonparametric statistical test was used to test whether each concentration was increasing or decreasing with time for selected physical properties and constituents, and a trend slope was estimated for each constituent at each site. Trends were examined for two time periods, 1988-2004 and 1994-2004. Results varied by site and by constituent. All sites and all constituents tested had at least one statistically significant trend in the period 1988-2004. Sulfate, total dissolved solids, nitrate, and orthophosphate have significant positive trends at multiple sites with no significant negative trend at any site. Alkalinity and arsenic have single significant positive trends. Hardness, calcium, magnesium, sodium, sodium-adsorption ratio, potassium, and chloride have both significant positive and negative trends. Ammonia has a single significant negative trend. Fewer significant trends were identified in 1994-2004, and all but one were positive. The contribution to the James River from Oakes Test Area drainage appears to have little effect on water quality in the James River.
Advancing the 3Rs in regulatory ecotoxicology: A pragmatic cross-sector approach.
Burden, Natalie; Benstead, Rachel; Clook, Mark; Doyle, Ian; Edwards, Peter; Maynard, Samuel K; Ryder, Kathryn; Sheahan, Dave; Whale, Graham; van Egmond, Roger; Wheeler, James R; Hutchinson, Thomas H
2016-07-01
The ecotoxicity testing of chemicals for prospective environmental safety assessment is an area in which a high number of vertebrates are used across a variety of industry sectors. Refining, reducing, and replacing the use of animals such as fish, birds, and amphibians for this purpose addresses the ethical concerns and the increasing legislative requirements to consider alternative test methods. Members of the UK-based National Centre for the Replacement, Refinement and Reduction of Animals in Research (NC3Rs) Ecotoxicology Working Group, consisting of representatives from academia, government organizations, and industry, have worked together over the past 6 y to provide evidence bases to support and advance the application of the 3Rs in regulatory ecotoxicity testing. The group recently held a workshop to identify the areas of testing, demands, and drivers that will have an impact on the future of animal use in regulatory ecotoxicology. As a result of these discussions, we have developed a pragmatic approach to prioritize and realistically address key opportunity areas, to enable progress toward the vision of a reduced reliance on the use of animals in this area of testing. This paper summarizes the findings of this exercise and proposes a pragmatic strategy toward our key long-term goals-the incorporation of reliable alternatives to whole-organism testing into regulations and guidance, and a culture shift toward reduced reliance on vertebrate toxicity testing in routine environmental safety assessment. Integr Environ Assess Manag 2016;12:417-421. © 2015 SETAC. © 2015 SETAC.
2005-11-01
Bottom Areas near Target Areas in the EGTTR, Florida.......................3-41 Figure 4-1. Safety Footprint Around Target Area...Thus, at many deep-water locations, it is not unusual for the low-frequency noise field to be influenced by contributions from tens or even... field at some range. Oilrigs, on the other hand, produce noise throughout the frequency domain. Recently, economic and political factors have not been
Neutral buoyancy testing of architectural and environmental concepts of space vehicle design
NASA Technical Reports Server (NTRS)
Lenda, J. A.; Rosener, A. A.; Stephenson, M. L.
1972-01-01
Design guidelines are presented that are applicable to providing habitability areas and furniture elements for extended periods in a zero gravity environment. This was accomplished by: (1) analyzing the existing habitability crew area requirements, mobility and restraint aids, cross-cultural design, and establishing a man model for zero gravity; (2) designing specific furniture elements, chair and table, and volumes for a stateroom, office, bathroom, galley, and wardroom; and (3) neutral buoyancy testing and evaluation of these areas.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Farnham, Irene; Rehfeldt, Kenneth
The purpose of this plan is to provide guidelines for effective communication and interfacing between Underground Test Area (UGTA) Activity participants, including the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) and its contractors. This plan specifically establishes the following: • UGTA mission, vision, and core values • Roles and responsibilities for key personnel • Communication with stakeholders • Guidance in key interface areas • Communication matrix
MTR WING A, TRA604, INTERIOR. BASEMENT. DETAIL OF A19 LAB ...
MTR WING A, TRA-604, INTERIOR. BASEMENT. DETAIL OF A-19 LAB AREA ALONG SOUTH WALL. SIGN ON FLOOR DIRECTS WORKERS TO OBTAIN WHOLE BODY FRISK UPON LEAVING AREA. SIGN ON EQUIPMENT IN CENTER OF VIEW REQUESTS WORKERS TO "NOTIFY HEALTH PHYSICS BEFORE WORKING ON THIS SYSTEM." CAMERA FACING SOUTHWEST. INL NEGATIVE NO. HD46-13-2. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Light Fighter Communication - On Today’s Chemical Battlefield
1988-06-03
quickly enough, the premature removal of masks, and the handling of contaminated clothing while evacuating patients. 9 Page 23 54 Śr" B. Doctrineo Two...Chemical lI’ Contaminated Areas PAPRICCA) found thai. the current chin strap worn by airborne soldiers is inacequate for.a jump into a 4 contaminated area...place in January 1981 entitled "Mobility Through Contaminated Areas Test (MOCAT)O. This was an eleven day test performed from 17-29 October 1980 at
A&M. TAN607 first floor plan for cold assembly area. Shows ...
A&M. TAN-607 first floor plan for cold assembly area. Shows special source vaults, X-ray room, instrument shops, and positions of large machines in component test laboratory. This drawing was re-drawn to show conditions in 1994. Ralph M. Parsons 902-3-ANP-607-A 100. Date of original: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 034-060-00-693-106752 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
Concentration of Actinides in Plant Mounds at Safety Test Nuclear Sites in Nevada
DOE Office of Scientific and Technical Information (OSTI.GOV)
David S. Shafer; Jenna Gommes
Plant mounds or blow-sand mounds are accumulations of soil particles and plant debris around large shrubs and are common features in deserts in the southwestern United States. Believed to be an important factor in their formation, the shrubs create surface roughness that causes wind-suspended particles to be deposited and resist further suspension. Shrub mounds occur in some plant communities on the Nevada Test Site, the Nevada Test and Training Range (NTTR), and Tonopah Test Range (TTR), including areas of surface soil contamination from past nuclear testing. In the 1970s as part of early studies to understand properties of actinides inmore » the environment, the Nevada Applied Ecology Group (NAEG) examined the accumulation of isotopes of Pu, {sup 241}Am, and U in plant mounds at safety test sites. The NAEG studies found concentrations of these contaminants to be greater in shrub mounds than in the surrounding areas of desert pavement. For example, at Project 57 on the NTTR, it was estimated that 15 percent of the radionuclide inventory of the site was associated with shrub mounds, which accounted for 17 percent of the surface area of the site, a ratio of inventory to area of 0.85. At Clean Slate III at the TTR, 29 percent of the inventory was associated with approximately 32 percent of the site covered by shrub mounds, a ratio of 0.91. While the total inventory of radionuclides in intershrub areas was greater, the ratio of radionuclide inventory to area was 0.40 and 0.38, respectively, at the two sites. The comparison between the shrub mounds and adjacent desert pavement areas was made for only the top 5 cm since radionuclides at safety test sites are concentrated in the top 5 cm of intershrub areas. Not accounting for radionuclides associated with the shrub mounds would cause the inventory of contaminants and potential exposure to be underestimated. As part of its Environmental Restoration Soils Subproject, the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office has proposed that the majority of its contaminated soil 'Corrective Action Units', including the safety test sites, be closed by fencing and posting with administrative controls. The concentration of actinides in the shrub mounds has important implications for postclosure management of the safety test sites. Because resuspension factors at safety test sites can be three to four orders-of-magnitude higher than soil sites associated with atmospheric tests where criticality occurred, the shrub mounds are an important factor in stabilization of actinide contaminants. Loss of shrubs associated with mounds from fire or plant die-back from drought could cause radionuclides at these sites to become more prone to suspension and water erosion until the sites are stabilized. Alternatively, although shrub mounds are usually composed of predominantly fine sand size particles, smaller silt and clay size particles in them are often high in CaCO{sub 3} content. The CaCO{sub 3} may act as a cementing agent to limit erosion of the shrub mounds even if the vegetation cover is temporarily lost.« less
Papinutto, N.; Schlaeger, R.; Panara, V.; Caverzasi, E.; Ahn, S.; Johnson, K.J.; Zhu, A.H.; Stern, W.A.; Laub, G.; Hauser, S.L.; Henry, R.G.
2018-01-01
PURPOSE In-vivo assessment of spinal cord gray matter (GM) and white matter (WM) could become pivotal to study various neurological diseases, but it is challenging because of insufficient GM/WM contrast provided by conventional MRI. Here we present and assess a procedure for measurement of spinal cord total cross-sectional area (TCA) and GM areas based on phase sensitive inversion recovery imaging (PSIR). MATERIALS AND METHODS We acquired 2D PSIR images at 3T at each disc level of the spinal axis on 10 healthy subjects and measured TCA, cord diameters, WM and GM area, and GM area/TCA ratio. We secondly investigated 32 healthy subjects at 4 selected levels (C2–C3, C3–C4, T8–T9, T9–T10, total acquisition time <8 minutes) and generated normative reference values of TCA and GM areas. We assessed test-retest, intra- and inter-operator reliability of the acquisition strategy and measurement steps. RESULTS The measurement procedure based on 2D PSIR imaging allowed TCA and GM area assessments along the entire spinal cord axis. The tests we performed revealed high test-retest/intra-operator reliability (mean coefficient of variation (COV) at C2–C3: TCA=0.41%, GM area=2.75%) and inter-operator reliability of the measurements (mean COV on the 4 levels: TCA=0.44%, GM area= 4.20%; mean intra-class correlation coefficient: TCA=0.998, GM area=0.906). CONCLUSION 2D PSIR allows reliable in-vivo assessment of spinal cord TCA, GM and WM areas in clinically feasible acquisition times. The area measurements presented here are in agreement with previous MRI and post-mortem studies. PMID:25483607
Computer-Based Testing: Test Site Security.
ERIC Educational Resources Information Center
Rosen, Gerald A.
Computer-based testing places great burdens on all involved parties to ensure test security. A task analysis of test site security might identify the areas of protecting the test, protecting the data, and protecting the environment as essential issues in test security. Protecting the test involves transmission of the examinations, identifying the…
The Use of Illustrations in Large-Scale Science Assessment: A Comparative Study
ERIC Educational Resources Information Center
Wang, Chao
2012-01-01
This dissertation addresses the complexity of test illustrations design across cultures. More specifically, it examines how the characteristics of illustrations used in science test items vary across content areas, assessment programs, and cultural origins. It compares a total of 416 Grade 8 illustrated items from the areas of earth science, life…
ERIC Educational Resources Information Center
Briscoe, Melissa
The project reported here was done in Kentucky to develop, field test, evaluate, and revise 300 competency-based vocational education (CBVE) instructional modules in five occupational areas. These areas are automobile mechanics, air-conditioning and refrigeration, court and conference reporter, alterationist, and gardening and groundskeeping. This…
Maclay, R.W.; Small, T.A.; Rettman, P.L.
1980-01-01
This report presents data and informat ion, and indicates other sources of data, on water level s, recharge, discharge, spec ifi c capacity, well yields, and aquifer tests for the Edwards aquifer in the Sa n Antonio area, Texas.
51. CONTEXT VIEW LOOKING NORTHWEST OF BUILDING 365 (ARMAMENT TESTING ...
51. CONTEXT VIEW LOOKING NORTHWEST OF BUILDING 365 (ARMAMENT TESTING BUILDING) IN BASE SPARES AREA WITH BUILDING 367 (ADMINISTRATIVE OFFICE BUILDING) IN MIDDLE GROUND AND BUILDING 368 (WAREHOUSE) IN BACKGROUND. - Loring Air Force Base, Weapons Storage Area, Northeastern corner of base at northern end of Maine Road, Limestone, Aroostook County, ME
ERIC Educational Resources Information Center
McGhee, Max B.; Cheek, Jimmy G.
An activity was undertaken to develop written criterion-referenced tests for each of the instructional areas comprising the Fundamentals of Agribusiness and Natural Resources Occupations Program. Designed to be taught at the ninth grade level, the program consists of six major instructional areas: agribusiness management, animal science, plant…
STORAGE AND RECIEVING, TRA662. ELEVATIONS. LOWBAY SECTION ON SOUTH SIDE ...
STORAGE AND RECIEVING, TRA-662. ELEVATIONS. LOW-BAY SECTION ON SOUTH SIDE WAS FLAMMABLE STORAGE AREA. HUMMEL HUMMEL & JONES 1038-MTR-ETR-662-A-3, 6/1960. INL INDEX NO. 532-0653-00-381-102036, REV. 3. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Development and evaluation of a contrast sensitivity perimetry test for patients with glaucoma.
Hot, Aliya; Dul, Mitchell W; Swanson, William H
2008-07-01
To design a contrast sensitivity perimetry (CSP) protocol that decreases variability in glaucomatous defects while maintaining good sensitivity to glaucomatous loss. Twenty patients with glaucoma and 20 control subjects were tested with a CSP protocol implemented on a monitor-based testing station. In the protocol 26 locations were tested over the central visual field with Gabor patches with a peak spatial frequency of 0.4 cyc/deg and a two-dimensional spatial Gaussian envelope, with most of the energy concentrated within a 4 degrees circular region. Threshold was estimated by a staircase method: Patients and 10 age-similar control subjects were also tested on conventional automated perimetry (CAP), with the 24-2 pattern with the SITA Standard testing strategy. The neuroretinal rim area of the patients was measured with a retinal tomograph (Retina Tomograph II [HRT]; Heidelberg Engineering, Heidelberg, Germany). A Bland-Altman analysis of agreement was used to assess test-retest variability, compare depth of defect shown by the two perimetric tests, and investigate the relations between contrast sensitivity and neuroretinal rim area. Variability showed less dependence on defect depth for CSP than for CAP (z = 9.3, P < 0.001). Defect depth was similar for CAP and CSP when averaged by quadrant (r = 0.26, P > 0.13). The relation between defect depth and rim area was more consistent with CSP than with CAP (z = 9, P < 0.001). The implementation of CSP was successful in reducing test-retest variability in glaucomatous defects. CSP was in general agreement with CAP in terms of depth of defect and was in better agreement than CAP with HRT-determined rim area.
Satellite-based products for forest fire prevention and recovery: the PREFER experience
NASA Astrophysics Data System (ADS)
Laneve, Giovanni; Bernini, Guido; Fusilli, Lorenzo; Marzialetti, Pablo
2016-08-01
PREFER is a three years projects funded in 2012 in the framework of the FP7 Emergency call. The project objective was to set up a space-based service infrastructure and up-to-date cartographic products, based on remote sensing data, to support the preparedness, prevention, recovery and reconstruction phases of the Forest Fires emergency cycle in the European Mediterranean Region. The products of PREFER were tested and evaluated during the training and the demonstration period of the project, which coincided with the forest fire season of 2015. The products were tested using the online PREFER service and the tests were linked to the pilot areas of the project which are Minho (Portugal), Messenia (Greece), Andalucía (Spain), Sardinia (Italy) and Corse (France). Testing was performed by members of the User Advisory Board (UAB) starting from the training event organized in Coimbra, Portugal in June 2015. The tests continued till the end of the fire season (October 2015) and the end users were provided with updated information for the areas of interest during the entire demonstration period. Due to data availability restrictions (in particular to ancillary required data) not all products were available for testing in all the test areas. However all the PREFER products were tested at least in one pilot area and in cooperation with at least one end user organization. It has to be mentioned that beyond the product suitability and usefulness to the end users the tests included evaluation of the usability of the web-based service of PREFER and the respective quality of service provided. This paper aims at presenting the results of the demonstration activity, the lessons learned and ideas for further enhancement of the developed products devoted to support prevention and recovery phases of the wildfire cycle.
Surface Area of Patellar Facets: Inferential Statistics in the Iraqi Population
Al-Zamili, Zaid; Omar, Rawan
2017-01-01
Background. The patella is the largest sesamoid bone in the body; its three-dimensional complexity necessitates biomechanical perfection. Numerous pathologies occur at the patellofemoral unit which may end in degenerative changes. This study aims to test the presence of statistical correlation between the surface areas of patellar facets and other patellar morphometric parameters. Materials and Methods. Forty dry human patellae were studied. The morphometry of each patella was measured using a digital Vernier Caliper, electronic balance, and image analyses software known as ImageJ. The patellar facetal surface area was correlated with patellar weight, height, width, and thickness. Results. Inferential statistics proved the existence of linear correlation of total facetal surface area and patellar weight, height, width, and thickness. The correlation was strongest for surface area versus patellar weight. The lateral facetal area was found persistently larger than the medial facetal area, the p value was found to be <0.001 (one-tailed t-test) for right patellae, and another significant p value of < 0.001 (one-tailed t-test) was found for left patellae. Conclusion. These data are vital for the restoration of the normal biomechanics of the patellofemoral unit; these are to be consulted during knee surgeries and implant designs and can be of an indispensable anthropometric, interethnic, and biometric value. PMID:28348891
Wright, W.G.
1985-01-01
Fracturing associated with lineaments are the primary influence on yields from wells in the coalfields of southwestern Virgnia. Graphical comparison of yield from wells shows that wells located in valleys with lineaments produce larger quantities of water than wells in valleys without lineaments. Pumping tests at wells located in valleys with lineaments indicate transmissivities as high as 598 ft2/d, caused principally by secondary permeability. Analysis of data collected from packer-injection tests in a test hole located on a ridge indicate relatively large hydraulic conductivities ranging from 2x10(sup -2) to 1x10(sup -1) feet per day in upper parts of the test hole, compared to values typical of unfractured rocks in the study area. Fracturing due to stress relief contribute to these large values. Yields from wells located on lineaments are consistently higher than well yields from wells in unfractured rock in the study area, but well yields from wells placed randomly in areas suspected of having stress relief fractures cannot be predicted. (USGS)
Team Oriented Robotic Exploration Task on Scorpion and K9 Platforms
NASA Technical Reports Server (NTRS)
Kirchner, Frank
2003-01-01
This final report describes the achievements that have been made in the project over the complete period of performance. The technical progress highlights the different areas of work in terms of Progress in Mechatronics, Sensor integration, Software Development. User Interfaces, Behavior Development and Experimental Results and System Testing. The different areas are: Mechatronics, Sensor integration, Software development, Experimental results and Basic System Testing, Behaviors Development and Advanced System Testing, User Interface and Wireless Communication.
Engineering sciences area and module performance and failure analysis area
NASA Technical Reports Server (NTRS)
Ross, R. G., Jr.; Runkle, L. D.
1982-01-01
Photovoltaic-array/power-conditioner interface studies are updated. An experiment conducted to evaluate different operating-point strategies, such as constant voltage and pilot cells, and to determine array energy losses when the array is operated off the maximum power points is described. Initial results over a test period of three and a half weeks showed a 2% energy loss when the array is operated at a fixed voltage. Degraded-array studies conducted at NE RES that used a range of simulated common types of degraded I-V curves are reviewed. The instrumentation installed at the JPL field-test site to obtain the irradiance data was described. Experiments using an optical filter to adjust the spectral irradiance of the large-area pulsed solar simulator (LAPSS) to AM1.5 are described. Residential-array research activity is reviewed. Voltage isolation test results are described. Experiments performed on one type of module to determine the relationship between leakage current and temperature are reviewed. An encapsulated-cell testing approach is explained. The test program, data reduction methods, and initial results of long-duration module testing are described.
None
2018-01-16
Take a virtual tour of the campus of Thomas Jefferson National Accelerator Facility. You can see inside our two accelerators, three experimental areas, accelerator component fabrication and testing areas, high-performance computing areas and laser labs.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Delineation, Testing, or Mining Plan, the bond amount shall be adjusted, if appropriate, to cover the... three areas: (1) The Gulf of Mexico and the area offshore the Atlantic Ocean; (2) The area offshore the...
Radiostrontium contamination of soil and vegetation within the Semipalatinsk test site.
Howard, B J; Semioschkina, N; Voigt, G; Mukusheva, M; Clifford, J
2004-12-01
The Semipalatinsk nuclear test site (STS) in the Republic of Kazakhstan was an important site for testing atomic bombs and other civil and military nuclear devices of the former Soviet Union. Results are presented from investigations on the extent of radiostrontium contamination in soils and vegetation at the technical areas of the STS, where the tests were conducted and in pastures used by farmers for grazing animals or for hay production. Our data are compared with those reported largely in the recent Russian language literature that has been reviewed. The extent of (90)Sr contamination of soil is highly variable over the STS with the highest values associated with the technical areas, particularly the Degelen mountains. Recently measured values in both the present data and the Russian language literature confirm the relatively high current contamination of soil and vegetation in the vicinity of tunnels and associated watercourses in the Degelen area. The proportion of (90)Sr in soil which could not be extracted with 6 M HCl was only an average of 20%, which is low compared to other test site areas and possibly indicates a relatively high mobility in this area, because the (90)Sr is derived from leakage from explosion tunnels along watercourses rather than being associated with fused silicates. A comparison of relative activity concentrations in soil and vegetation suggests that the transfer of (90)Sr to vegetation on the STS is high compared to that of (137)Cs and plutonium.
Learning needs in clinical biochemistry for doctors in foundation years.
Khromova, Victoria; Gray, Trevor A
2008-01-01
Most medical school curricula have reduced the amount of time available for teaching in pathology despite the fact that junior staff in the early stages of their training were responsible for requesting the majority of pathology tests on acutely ill hospital patients. So, the lack of specific training in this area means that test requesting may be poorly performed and the results ill understood by these staff. This paper describes a questionnaire, which was designed to assist laboratory staff providing targeted teaching in this area. Doctors in Foundation year 1 (F1) and Foundation year 2 (F2) in Sheffield teaching hospitals were given a questionnaire to ascertain how confident they were in requesting and interpreting the results of clinical biochemistry tests. The doctors were also asked about which areas of laboratory medicine they would like to be taught. Responses were received from 82 doctors, about half those in F1 and F2. The survey revealed areas where juniors are less confident in requesting tests and interpreting results. Despite lack of confidence in interpreting the result, 18% were confident about requesting tests. Doctors were also unsure of the effects of common problems like haemolysis on the interpretation of results. More than 70% of the doctors requested specific teaching in these areas. Foundation doctors have learning needs in clinical biochemistry, addressing which would assist them in patient care. While better training in medical school may help in future, there are specific needs for those on the wards now that require targeted teaching.
Artes, Paul H; Henson, David B; Harper, Robert; McLeod, David
2003-06-01
To compare a multisampling suprathreshold strategy with conventional suprathreshold and full-threshold strategies in detecting localized visual field defects and in quantifying the area of loss. Probability theory was applied to examine various suprathreshold pass criteria (i.e., the number of stimuli that have to be seen for a test location to be classified as normal). A suprathreshold strategy that requires three seen or three missed stimuli per test location (multisampling suprathreshold) was selected for further investigation. Simulation was used to determine how the multisampling suprathreshold, conventional suprathreshold, and full-threshold strategies detect localized field loss. To determine the systematic error and variability in estimates of loss area, artificial fields were generated with clustered defects (0-25 field locations with 8- and 16-dB loss) and, for each condition, the number of test locations classified as defective (suprathreshold strategies) and with pattern deviation probability less than 5% (full-threshold strategy), was derived from 1000 simulated test results. The full-threshold and multisampling suprathreshold strategies had similar sensitivity to field loss. Both detected defects earlier than the conventional suprathreshold strategy. The pattern deviation probability analyses of full-threshold results underestimated the area of field loss. The conventional suprathreshold perimetry also underestimated the defect area. With multisampling suprathreshold perimetry, the estimates of defect area were less variable and exhibited lower systematic error. Multisampling suprathreshold paradigms may be a powerful alternative to other strategies of visual field testing. Clinical trials are needed to verify these findings.
Ferreira, Fernanda Teixeira; Fidelis, Thiago André; Pereira, Thiago Almeida; Otoni, Alba; Queiroz, Leonardo Campos; Amâncio, Frederico Figueiredo; Antunes, Carlos Maurício; Lambertucci, José Roberto
2017-01-01
The Kato-Katz technique is the standard diagnostic test for Schistosoma mansoni infection in rural areas. However, the utility of this method is severely limited by the day-to-day variability in host egg excretion in the stool. In high-transmission areas, the point-of-care circulating cathodic antigen (POC-CCA) urine assay has proven to be a reliable test. However, investigations of the reliability of the POC-CCA assay in low-transmission regions are under way. This study aimed to evaluate the sensitivity and specificity of the POC-CCA assay and the morbidity of schistosomiasis in a low-endemic area in Brazil. Pains City is a low-transmission zone for schistosomiasis. A total of 300 subjects aged 7-76 years were randomly selected for the POC-CCA cassette test. For S. mansoni diagnosis, three stool samples on six slides were compared with one urine sample for each subject. The sensitivity and specificity in the absence of a gold standard were calculated using latent class analysis. Clinical examinations and abdominal ultrasounds were performed in 181 volunteers to evaluate morbidity associated with schistosomiasis. The sensitivity and specificity of the Kato-Katz technique were 25.6% and 94.6%, respectively. By contrast, the sensitivity and specificity of the POC-CCA assay were 68.1% and 72.8%, respectively. Hepatosplenic schistosomiasis was diagnosed in two patients (1.1%). Overall, the POC-CCA urine assay proved to be a useful test for diagnosing S. mansoni in a low-endemic area in Brazil. Severe clinical forms of schistosomiasis can be present even in such low-endemic areas.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Ning; Rutherford, Phil
2007-09-01
This Annual Site Environmental Report (ASER) for 2006 describes the environmental conditions related to work performed for the Department of Energy (DOE) at Area IV of Boeing’s Santa Susana Field Laboratory (SSFL). In the past, the Energy Technology Engineering Center (ETEC), a government-owned, company-operated test facility, was located in Area IV. The operations in Area IV included development, fabrication, and disassembly of nuclear reactors, reactor fuel, and other radioactive materials. Other activities in the area involved the operation of large-scale liquid metal facilities that were used for testing non-nuclear liquid metal fast breeder components. All nuclear work was terminated inmore » 1988; all subsequent radiological work has been directed toward decontamination and decommissioning (D&D) of the former nuclear facilities and their associated sites. Closure of the liquid metal test facilities began in 1996. Results of the radiological monitoring program for the calendar year 2006 continue to indicate that there are no significant releases of radioactive material from Area IV of SSFL. All potential exposure pathways are sampled and/or monitored, including air, soil, surface water, groundwater, direct radiation, transfer of property (land, structures, waste), and recycling.« less
Measurement and interpretation of skin prick test results.
van der Valk, J P M; Gerth van Wijk, R; Hoorn, E; Groenendijk, L; Groenendijk, I M; de Jong, N W
2015-01-01
There are several methods to read skin prick test results in type-I allergy testing. A commonly used method is to characterize the wheal size by its 'average diameter'. A more accurate method is to scan the area of the wheal to calculate the actual size. In both methods, skin prick test (SPT) results can be corrected for histamine-sensitivity of the skin by dividing the results of the allergic reaction by the histamine control. The objectives of this study are to compare different techniques of quantifying SPT results, to determine a cut-off value for a positive SPT for histamine equivalent prick -index (HEP) area, and to study the accuracy of predicting cashew nut reactions in double-blind placebo-controlled food challenge (DBPCFC) tests with the different SPT methods. Data of 172 children with cashew nut sensitisation were used for the analysis. All patients underwent a DBPCFC with cashew nut. Per patient, the average diameter and scanned area of the wheal size were recorded. In addition, the same data for the histamine-induced wheal were collected for each patient. The accuracy in predicting the outcome of the DBPCFC using four different SPT readings (i.e. average diameter, area, HEP-index diameter, HEP-index area) were compared in a Receiver-Operating Characteristic (ROC) plot. Characterizing the wheal size by the average diameter method is inaccurate compared to scanning method. A wheal average diameter of 3 mm is generally considered as a positive SPT cut-off value and an equivalent HEP-index area cut-off value of 0.4 was calculated. The four SPT methods yielded a comparable area under the curve (AUC) of 0.84, 0.85, 0.83 and 0.83, respectively. The four methods showed comparable accuracy in predicting cashew nut reactions in a DBPCFC. The 'scanned area method' is theoretically more accurate in determining the wheal area than the 'average diameter method' and is recommended in academic research. A HEP-index area of 0.4 is determined as cut-off value for a positive SPT. However, in clinical practice, the 'average diameter method' is also useful, because this method provides similar accuracy in predicting cashew nut allergic reactions in the DBPCFC. Trial number NTR3572.
24. CLOSEUP OF MOUNT FOR F1 ENGINE ON STATIC TEST ...
24. CLOSE-UP OF MOUNT FOR F-1 ENGINE ON STATIC TEST TOWER WITH STRUCTURAL DYNAMICS TEST STAND IN DISTANCE. - Marshall Space Flight Center, Saturn Propulsion & Structural Test Facility, East Test Area, Huntsville, Madison County, AL
PERSPECTIVE VIEW LOOKING SOUTHEAST OF THE SATURN I TEST. NOTE ...
PERSPECTIVE VIEW LOOKING SOUTHEAST OF THE SATURN I TEST. NOTE THE GANTRY CRANE USED TO MANEUVER ROCKETS INTO THE TEST STAND. - Marshall Space Flight Center, Saturn Propulsion & Structural Test Facility, East Test Area, Huntsville, Madison County, AL
[Estimates of the size of inhibitory areas in crowding effects in periphery].
Bondarko, V M; Danilova, M V; Solnushkin, S D; Chikhman, V N
2014-01-01
In psychophysical experiments we studied how surround influences recognition of test objects. The tests were low-contrast Landolt rings of the size 1.1, 1.5 and 2.3 deg. Their centers were located at 13.2 deg from the fixation point. The additional objects were similar Landolt rings or rings without gaps. The distance between the centers of the test and the additional objects varied from 2.2 to 13.2 deg. Inone experiment, the task of the observer was to identify both the test objects and the surrounding objects. In the second experiment the stimulus layout was the same, but'identification of only the test stimulus was required. In both experiments, deterioration of performance was found at all distances between the test objects and the surround, but the deterioration was more significant when the observer carried out the dual task. The data showed that the size of the inhibitory areas in our case does not comply with the Bouma low which states that the size of the interaction areas are equal to half of the eccentricity where the test is presented. Further deterioration of performance in the dual task reveals the contribution of attention into peripheral crowding effects.
1. VIEW NORTHEAST, LEFT TO RIGHT COLD CALIBRATION TEST STAND ...
1. VIEW NORTHEAST, LEFT TO RIGHT COLD CALIBRATION TEST STAND COLD CALIBRATION BLOCKHOUSE IN FOREGROUND. - Marshall Space Flight Center, East Test Area, Cold Calibration Test Stand, Huntsville, Madison County, AL
13. TOP OF STATIC TEST TOWER VIEW OF STEEL TRUSS ...
13. TOP OF STATIC TEST TOWER VIEW OF STEEL TRUSS STRUCTURE AND OVERHEAD CRANE. - Marshall Space Flight Center, Saturn Propulsion & Structural Test Facility, East Test Area, Huntsville, Madison County, AL
NASA's Hydrogen Outpost: The Rocket Systems Area at Plum Brook Station
NASA Technical Reports Server (NTRS)
Arrighi, Robert S.
2016-01-01
"There was pretty much a general knowledge about hydrogen and its capabilities," recalled former researcher Robert Graham. "The question was, could you use it in a rocket engine? Do we have the technology to handle it? How will it cool? Will it produce so much heat release that we can't cool the engine? These were the questions that we had to address." The National Aeronautics and Space Administration's (NASA) Glenn Research Center, referred to historically as the Lewis Research Center, made a concerted effort to answer these and related questions in the 1950s and 1960s. The center played a critical role transforming hydrogen's theoretical potential into a flight-ready propellant. Since then NASA has utilized liquid hydrogen to send humans and robots to the Moon, propel dozens of spacecraft across the universe, orbit scores of satellite systems, and power 135 space shuttle flights. Rocket pioneers had recognized hydrogen's potential early on, but its extremely low boiling temperature and low density made it impracticable as a fuel. The Lewis laboratory first demonstrated that liquid hydrogen could be safely utilized in rocket and aircraft propulsion systems, then perfected techniques to store, pump, and cleanly burn the fuel, as well as use it to cool the engine. The Rocket Systems Area at Lewis's remote testing area, Plum Brook Station, played a little known, but important role in the center's hydrogen research efforts. This publication focuses on the activities at the Rocket Systems Area, but it also discusses hydrogen's role in NASA's space program and Lewis's overall hydrogen work. The Rocket Systems Area included nine physically modest test sites and three test stands dedicated to liquid-hydrogen-related research. In 1962 Cleveland Plain Dealer reporter Karl Abram claimed, "The rocket facility looks more like a petroleum refinery. Its test rigs sprout pipes, valves and tanks. During the night test runs, excess hydrogen is burned from special stacks in the best Oklahoma oil field tradition." Besides the Rocket Systems Area, Plum Brook Station also included a nuclear test reactor, a large vacuum tank, a hypersonic wind tunnel, and a full-scale upper-stage rocket stand. The Rocket Systems Area operated from 1961 until NASA shut down all of Plum Brook in 1974. The center reopened Plum Brook in the late 1980s and continues to use several test facilities. The Rocket Systems Area, however, was not restored. Today Plum Brook resembles a nature preserve more than an oil refinery. Lush fields and forests separate the large test facilities. Until recently, the abandoned Rocket Systems Area structures and equipment were visible amongst the greenery. These space-age ruins, particularly the three towers, stood as silent sentinels over the sparsely populated reservation. Few knew the story of these mysterious facilities when NASA removed them in the late 2000s.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patrick Matthews
2010-03-01
Corrective Action Unit (CAU) 375 is located in Areas 25 and 30 of the Nevada Test Site, which is approximately 65 miles northwest of Las Vegas, Nevada. Corrective Action Unit 375 comprises the two corrective action sites (CASs) listed below: • 25-23-22, Contaminated Soils Site • 30-45-01, U-30a, b, c, d, e Craters Existing information on the nature and extent of potential contamination present at the CAU 375 CASs is insufficient to evaluate and recommend corrective action alternatives (CAAs). This document details an investigation plan that will provide for the gathering of sufficient information to evaluate and recommend CAAs. Correctivemore » Action Site 25-23-22 is composed of the releases associated with nuclear rocket testing at Test Cell A (TCA). Test Cell A was used to test and develop nuclear rocket motors as part of the Nuclear Rocket Development Station from its construction in 1958 until 1966, when rocket testing began being conducted at Test Cell C. The rocket motors were built with an unshielded nuclear reactor that produced as much as 1,100 kilowatts (at full power) to heat liquid hydrogen to 4,000 degrees Fahrenheit, at which time the expanded gases were focused out a nozzle to produce thrust. The fuel rods in the reactor were not clad and were designed to release fission fragments to the atmosphere, but due to vibrations and loss of cooling during some operational tests, fuel fragments in excess of planned releases became entrained in the exhaust and spread in the immediate surrounding area. Cleanup efforts have been undertaken at times to collect the fuel rod fragments and other contamination. Previous environmental investigations in the TCA area have resulted in the creation of a number of use restrictions. The industrial area of TCA is encompassed by a fence and is currently posted as a radioactive material area. Corrective Action Site 30-45-01 (releases associated with the Buggy Plowshare test) is located in Area 30 on Chukar Mesa. It was a Plowshare test where five nuclear devices were buried 140 feet (ft) deep in a row at 150-ft intervals. These devices were detonated on March 12, 1968, to produce a trench 254 ft wide, 865 ft long, and 70 ft deep. The mesa where the test was conducted is surrounded on three sides by ravines, and the entire end of the mesa is fenced and posted as a contamination area. These sites are being investigated because existing information on the nature and extent of potential contamination is insufficient to evaluate and recommend CAAs. Additional information will be obtained by conducting a corrective action investigation before evaluating CAAs and selecting the appropriate corrective action for each CAS. The results of the field investigation will support a defensible evaluation of viable CAAs that will be presented in the Corrective Action Decision Document. The sites will be investigated based on the data quality objectives (DQOs) developed on December 2, 2009, by representatives of the Nevada Division of Environmental Protection and the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office. The DQO process was used to identify and define the type, amount, and quality of data needed to develop and evaluate appropriate corrective actions for CAU 375.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, N.; Davis, S.
1979-07-01
Performance and handling tests on the Calspan RSV were performed in Italy by the Istituto Sperimentale Auto E Motori (ISAM) and in West Germany by Volkswagenwerk AG Wolfsburg. The ISAM tests evaluated the Calspan RSV in the areas of fuel economy, vehicle response, braking and handling, and driver environment. The Volkswagen tests evaluated the Calspan RSV in the areas of braking, steering, handling, and overturning immunity. The ISAM tests are unlike any previously used to evaluate American vehicles. Therefore, the Calspan RSV results are compared to those of ten European cars which had undergone identical tests. The Volkswagen test proceduresmore » were identical to those specified in the Research Safety Vehicle program. The Calspan RSV results are compared to the RSV specifications for these tests.« less
13. BUILDING NO. 621, INTERIOR, TOP OF BLASTING TUB UNDERNEATH ...
13. BUILDING NO. 621, INTERIOR, TOP OF BLASTING TUB UNDERNEATH SAWDUST HOPPER. BLASTING TUB HAS DOUBLE WALLS OF 3/4' THICK STEEL ARMOR PLATE. CHARGE TO BE TESTED IS BURIED IN SAWDUST WITH FLAME RESISTANT CHEMICALS. ELEVATOR BEHIND TUB CARRIES SAWDUST BACK TO TOP OF SAWDUST HOPPER AFTER TEST IS COMPLETED AND SAWDUST IN BLASTING TUB HAS BEEN SIFTED FOR SHELL FRAGMENTS. LOUVERS IN WALLS ARE HINGED FREELY SO THEY OPEN TO RELIEVE BLAST PRESSURE DURING A TEST. - Picatinny Arsenal, 600 Area, Test Areas District, State Route 15 near I-80, Dover, Morris County, NJ
Aboveground Injection Sytem Construction and Mecahnical Integrity Test Plan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Jun
An In-Situ Bioremediation (ISB) Pilot Test Treatability Study is planned at Sandia National Laboratories, New Mexico (SNL/NM) Technical Area-V (TA-V) Groundwater Area of Concern. The Treatability Study is designed to gravity inject an electron-donor substrate and bioaugmentation bacteria into groundwater using an injection well. The constituents of concern (COCs) are nitrate and trichloroethene (TCE). The Pilot Test Treatability Study will evaluate the effectiveness of bioremediation and COC treatment over a prescribed period of time. Results of the pilot test will provide data that will be used to evaluate the cost and effectiveness of a fullscale system.
9. WEST SIDE, TEST STAND AND SUPERSTRUCTURE. TEST STAND 1B ...
9. WEST SIDE, TEST STAND AND SUPERSTRUCTURE. TEST STAND 1-B IN DISTANCE. Looking east. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA
8. TEST STAND 15, INVERTED ENGINE FIRING TEST, CIRCA 1963. ...
8. TEST STAND 1-5, INVERTED ENGINE FIRING TEST, CIRCA 1963. Original is a color print. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-5, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-10
... running to unintended areas, etc. Wound dehiscence Bench Testing, Shelf Life Testing, Animal Testing, Clinical Studies, Labeling. Adverse tissue reaction and chemical Biocompatibility Animal burns. Testing, Clinical Studies. Infection Bench Testing, Biocompatibility Animal Testing, Clinical Studies, Sterility...
Effect of psychological stress on gastric motility assessed by electrical bio-impedance.
Huerta-Franco, María Raquel; Vargas-Luna, Miguel; Montes-Frausto, Juana Berenice; Morales-Mata, Ismael; Ramirez-Padilla, Lorena
2012-09-28
To evaluate gastric motility using electrical bio-impedance (EBI) and gastric changes as a result of stress induced by psychological tests. A group of 57 healthy women, aged 40-60 years, was recruited, and a clinical history and physical examination were performed. The women were free from severe anxiety, chronic or acute stress, severe depression, mental diseases and conditions that affect gastric activity. The women were evaluated under fasting conditions, and using a four-electrode configuration, the gastric signals were obtained through a BIOPAC MP-150 system. The volunteers were evaluated using the following paradigm: basal state, recording during the Stroop Test, intermediate resting period, recording during the Raven Test, and a final resting period. We analyzed the relative areas of the frequency spectrum: A1 (1-2 cpm), A2 (2-4 cpm), A3 (4-8 cpm), and A4 (8-12 cpm), as well as the median of area A2 + A3. The data were analyzed by an autoregressive method using a Butterworth filter with MatLab and Origin. Analysis of variance (ANOVA) and Friedman ANOVA (for nonparametric variables) were performed; in addition, pairs of groups were compared using the T dependent and Wilcoxon T tests. The results of the main values of area A2 were not significantly different comparing the five steps of the experimental paradigm. Nevertheless, there was a tendency of this A2 region to decrease during the stress tests, with recuperation at the final resting step. When an extended gastric region was considered (1-4 cpm), significant differences with the psychological stress tests were present (F = 3.85, P = 0.005). The A3 region also showed significant changes when the stress psychological tests were administered (F = 7.25, P < 0.001). These differences were influenced by the changes in the adjacent gastric region of A2. The parameter that we proposed in previous studies for the evaluation of gastric motility by electrical bio-impedance (EBI) was the median of the area under the region from 2 to 8 cpm (A2 + A3). The mean values of these frequencies (median of the A2 + A3 area) with the stress test showed significant changes (F = 5.5, P < 0.001). The results of the Wilcoxon T test for the A4 area parameter, which is influenced by the breathing response, changed significantly during the Raven stress test (P < 0.05). We confirm that the gastric response to acute psychological stress can be evaluated by short-term EBI.
Tanaka, K; Tchaijunusova, N J; Takatsuji, T; Gusev, B I; Sakerbaev, A K; Hoshi, M; Kamada, N
2000-03-01
The Semipalatinsk area is highly contaminated with radioactive fallout from 40 years of continuous nuclear testing. The biological effects on human health in this area have not been studied. Significant remaining radioactivities include long-lived radioisotopes of 238,239,400Pu, 137Cs and 90Sr. To evaluate the long-term biological effects of the radioactive fallout, the incidence of micronuclei in lymphocytes from residents of the area was observed. Blood was obtained from 10 residents (5 females and 5 males, aged 47 to 55 years old) from each of the 3 areas of Znamenka, Dolon and Semipalatinsk, which are about 50-150 km from the nuclear explosion test site. For micronucleus assay, PHA-stimulated lymphocytes were cultured for 72 h and cytochalasin B was added at 44 h for detecting binuclear lymphocytes. Five thousand binuclear lymphocytes in each resident were scored. The means of micronucleus counts in 1,000 lymphocytes in residents of Semipalatinsk, Dolon and Znamenka were 16.3, 12.6, and 7.80, respectively, which were higher than those of the normal Japanese persons (4.66). These values were equivalent to the results obtained from 0.187-0.47 Gy of chronic exposure to gamma-rays at a dose rate of 0.02 cGy/min. The high incidence of micronuclei in residents of the Semipalatinsk nuclear test site area was mainly caused by internal exposure rather than external exposure received for the past 40 years.
Nagata, Kohei; Kilgore, Brian D.; Beeler, Nicholas M.; Nakatani, Masao
2014-01-01
During localized slip of a laboratory fault we simultaneously measure the contact area and the dynamic fault normal elastic stiffness. One objective is to determine conditions where stiffness may be used to infer changes in area of contact during sliding on nontransparent fault surfaces. Slip speeds between 0.01 and 10 µm/s and normal stresses between 1 and 2.5 MPa were imposed during velocity step, normal stress step, and slide-hold-slide tests. Stiffness and contact area have a linear interdependence during rate stepping tests and during the hold portion of slide-hold-slide tests. So long as linearity holds, measured fault stiffness can be used on nontransparent materials to infer changes in contact area. However, there are conditions where relations between contact area and stiffness are nonlinear and nonunique. A second objective is to make comparisons between the laboratory- and field-measured changes in fault properties. Time-dependent changes in fault zone normal stiffness made in stress relaxation tests imply postseismic wave speed changes on the order of 0.3% to 0.8% per year in the two or more years following an earthquake; these are smaller than postseismic increases seen within natural damage zones. Based on scaling of the experimental observations, natural postseismic fault normal contraction could be accommodated within a few decimeter wide fault core. Changes in the stiffness of laboratory shear zones exceed 10% per decade and might be detectable in the field postseismically.
How is the chlorophyll count affected by burned and unburned marsh areas?
NASA Astrophysics Data System (ADS)
Kendrick, C.
2017-12-01
Does marsh burnings, either man made or natural, hinder or help Louisiana's vitally important coastal plant life? Does the carbon produced from the fires have a negative effect on the chlorophyll count of these precious living protective barriers? Or does it help contribute to raising the plants chlorophyll count? Along Louisiana's Gulf Coast, marsh burnings are conducted every 2-4 years to destroy some of the Spartina patens. Fires and smoke may have an effect on the chlorophyll count of the plants found in Louisiana's marshes. Peat burns, root burns, and cover burns are the three types of marsh fires. These burns can be either man made or started by natural causes. Peat burns occur when the soil is dry due to a drained marsh. Root burns occur when plant roots are burned without the soil being consumed. Cover burns occur when several centimeters of water covers the soil. Cover burns are often used by Wildlife and Fisheries personnel to promote preferred plant food growth like Scirpus olneyi rather than the dominant Spartina patens. Our project was conducted by testing marsh plants and obtaining chlorophyll count of both a burned (cover burn) and an unburned area. Approximately one year after the burn, in August 2015, we tested the burned area's site. We retested the same site in December 2016. The results from our testing showed that there was a slightly higher chlorophyll count in the burned area. The chlorophyll count average from the two testing days was 33.5 in the burned area and 30.15 in the unburned area. Our hypothesis was that the chlorophyll content of "controlled" burned wetland areas will have a higher amount than the "no" burn area. The experiment results supported this hypothesis by showing an increase of 3.35 average in the burned area.
Grasso, Dennis N.
2003-01-01
Surface effects maps were produced for 72 of 89 underground detonations conducted at the Frenchman Flat, Rainier Mesa and Aqueduct Mesa, Climax Stock, Shoshone Mountain, Buckboard Mesa, and Dome Mountain testing areas of the Nevada Test Site between August 10, 1957 (Saturn detonation, Area 12) and September 18, 1992 (Hunters Trophy detonation, Area 12). The ?Other Areas? Surface Effects Map Database, which was used to construct the maps shown in this report, contains digital reproductions of these original maps. The database is provided in both ArcGIS (v. 8.2) geodatabase format and ArcView (v. 3.2) shapefile format. This database contains sinks, cracks, faults, and other surface effects having a combined (cumulative) length of 136.38 km (84.74 mi). In GIS digital format, the user can view all surface effects maps simultaneously, select and view the surface effects of one or more sites of interest, or view specific surface effects by area or site. Three map layers comprise the database. They are: (1) the surface effects maps layer (oase_n27f), (2) the bar symbols layer (oase_bar_n27f), and (3) the ball symbols layer (oase_ball_n27f). Additionally, an annotation layer, named 'Ball_and_Bar_Labels,' and a polygon features layer, named 'Area12_features_poly_n27f,' are contained in the geodatabase version of the database. The annotation layer automatically labels all 295 ball-and-bar symbols shown on these maps. The polygon features layer displays areas of ground disturbances, such as rock spall and disturbed ground caused by the detonations. Shapefile versions of the polygon features layer in Nevada State Plane and Universal Transverse Mercator projections, named 'area12_features_poly_n27f.shp' and 'area12_features_poly_u83m.shp,' are also provided in the archive.
Mshelbwala, P P; Ogunkoya, A B; Maikai, B V
2013-01-01
The study was carried out in eight dogs slaughtering outlets within four Local Government Areas of the State for the determination of rabies antigen in the saliva and brain of apparently healthy dogs slaughtered for human consumption. A total of one hundred (100) samples each of saliva and brain were collected before and after slaughter, respectively, between April to June, 2013, in the selected areas. The saliva was subjected to rapid immune-chromatographic test (RICT) while direct fluorescent antibody test (DFAT) was carried out on the brain samples. Structured questionnaire was administered to nineteen (19) dog meat processors comprising 18 males and 1 female in the selected areas. Sixty four percent of the samples tested were from female dogs while 36% were from males, 5% tested positive for rabies antigen with the use of both tests; there was no statistical association between sex and rabies status of the dogs sampled (P > 0.05). Butchers bitten during the course of slaughtering were 94.7% out of which 72.8% utilized traditional method of treatment and only 27.8% reported to the hospital for proper medical attention. This study has established the presence of rabies antigen in apparently healthy dogs in the study area.
Pfaff, A; Schoenfeld, A; Ahmed, K M; van Geen, A
2017-01-01
This study considers potential policy responses to the still very high levels of exposure to arsenic (As) caused by drinking water from shallow tubewells in rural Bangladesh. It examines a survey of 4,109 households in 76 villages of Araihazar upazila conducted two years after a national testing campaign swept through the area. The area is adjacent to the region where a long-term study was initiated in 2000 and where households are periodically reminded of health risks associated with well-water elevated in As. Results confirm that testing spurs switching away from unsafe wells, although the 27% fraction who switched was only about half of that in the long-term study area. By village, the fraction of households that switched varied with the availability of safe wells and the distance from the long-term study area. Lacking follow-up testing, two years only after the campaign 21% of households did not know the status of their well and 21% of households with an unsafe well that switched did so to an untested well. Well testing is again urgently needed in Bangladesh and should be paired with better ways to raise awareness and the installation of additional deep community wells.
NASA Astrophysics Data System (ADS)
Robin, C.; Gérard, M.; Quinaud, M.; d'Arbigny, J.; Bultel, Y.
2016-09-01
The prediction of Proton Exchange Membrane Fuel Cell (PEMFC) lifetime is one of the major challenges to optimize both material properties and dynamic control of the fuel cell system. In this study, by a multiscale modeling approach, a mechanistic catalyst dissolution model is coupled to a dynamic PEMFC cell model to predict the performance loss of the PEMFC. Results are compared to two 2000-h experimental aging tests. More precisely, an original approach is introduced to estimate the loss of an equivalent active surface area during an aging test. Indeed, when the computed Electrochemical Catalyst Surface Area profile is fitted on the experimental measures from Cyclic Voltammetry, the computed performance loss of the PEMFC is underestimated. To be able to predict the performance loss measured by polarization curves during the aging test, an equivalent active surface area is obtained by a model inversion. This methodology enables to successfully find back the experimental cell voltage decay during time. The model parameters are fitted from the polarization curves so that they include the global degradation. Moreover, the model captures the aging heterogeneities along the surface of the cell observed experimentally. Finally, a second 2000-h durability test in dynamic operating conditions validates the approach.
Aeroacoustic Analysis of Fan Noise Reduction With Increased Bypass Nozzle Area
NASA Technical Reports Server (NTRS)
Woodward, Richard P.; Hughes, Christopher E.; Podboy, Gary G.
2005-01-01
An advanced model turbofan was tested in the NASA Glenn 9-by 15-Foot Low Speed Wind Tunnel (9x15 LSWT) to explore far field acoustic effects of increased bypass nozzle area. This fan stage test was part of the NASA Glenn Fan Broadband Source Diagnostic Test, second entry (SDT2) which acquired aeroacoustic results over a range of test conditions. The baseline nozzle was sized to produce maximum stage performance at cruise condition. However, the wind tunnel testing is conducted near sea level condition. Therefore, in order to simulate and obtain performance at other operating conditions, two additional nozzles were designed and tested one with +5 percent increase in weight flow (+5.4 percent increase in nozzle area compared with the baseline nozzle), sized to simulate the performance at the stage design point (takeoff) condition, and the other with a +7.5 percent increase in weight flow (+10.9 percent increase in nozzle area) sized for maximum weight flow with a fixed nozzle at sea level condition. Measured acoustic benefits with increased nozzle area were very encouraging, showing overall sound power level (OAPWL) reductions of 2 or more dB while the stage thrust actually increased by 2 to 3 percent except for the most open nozzle at takeoff rotor speed where stage performance decreased. Effective perceived noise levels for a 1500 ft engine flyover and 3.35 scale factor showed a similar noise reduction of 2 or more EPNdB. Noise reductions, principally in the level of broadband noise, were observed everywhere in the far field. Laser Doppler Velocimetry measurements taken downstream of the rotor showed that the total turbulent velocity decreased with increasing nozzle flow, which may explain the reduced rotor broadband noise levels.
Measuring the Sensitivity and Construct Validity of 6 Utility Instruments in 7 Disease Areas.
Richardson, Jeff; Iezzi, Angelo; Khan, Munir A; Chen, Gang; Maxwell, Aimee
2016-02-01
Health services that affect quality of life (QoL) are increasingly evaluated using cost utility analyses (CUA). These commonly employ one of a small number of multiattribute utility instruments (MAUI) to assess the effects of the health service on utility. However, the MAUI differ significantly, and the choice of instrument may alter the outcome of an evaluation. The present article has 2 objectives: 1) to compare the results of 3 measures of the sensitivity of 6 MAUI and the results of 6 tests of construct validity in 7 disease areas and 2) to rank the MAUI by each of the test results in each disease area and by an overall composite index constructed from the tests. Patients and the general public were administered a battery of instruments, which included the 6 MAUI, disease-specific QoL instruments (DSI), and 6 other comparator instruments. In each disease area, instrument sensitivity was measured 3 ways: by the unadjusted mean difference in utility between public and patient groups, by the value of the effect size, and by the correlation between MAUI and DSI scores. Content and convergent validity were tested by comparison of MAUI utilities and scores from the 6 comparator instruments. These included 2 measures of health state preferences, measures of subjective well-being and capabilities, and generic measures of physical and mental QoL derived from the SF-36. The apparent sensitivity of instruments varied significantly with the measurement method and by disease area. Validation test results varied with the comparator instruments. Notwithstanding this variability, the 15D, AQoL-8D, and the SF-6D generally achieved better test results than the QWB and EQ-5D-5L. © The Author(s) 2015.
Performance of the Anti-Coincidence Detector on the GLAST Large Area Telescope
NASA Technical Reports Server (NTRS)
Thompson, D. J.; Charles, E.; Hartman, R. C.; Moiseev, A. A.; Ormes, J. F.
2007-01-01
The Anti-Coincidence Detector (ACD), the outermost detector layer in the Gamma-ray Large Area Space Telescope (GLAST) Large Area Telescope (LAT), is designed to detect and veto incident cosmic ray charged particles, which outnumber cosmic gamma rays by 3-4 orders of magnitude. The challenge in ACD design is that it must have high (0.9997) detection efficiency for singly-charged relativistic particles, but must also have a low probability for self-veto of high-energy gammas by backplash radiation from interactions in the LAT calorimeter. Simulations and tests demonstrate that the ACD meete its design requirements. The performance of the ACD has remained stable thrugh stand-alone environmental testing, shipment across the U.S. installation onto the LAT, shipment back across the U.S., LAT environmental testing, and shipment to Arizona. As part of the fully-assembled GLAST observatory, the ACD is being readied for final testing before launch.
Fabrication and radio frequency test of large-area MgB 2 films on niobium substrates
Ni, Zhimao; Guo, Xin; Welander, Paul B.; ...
2017-01-19
Magnesium diboride (MgB 2) is a promising candidate material for superconducting radio frequency (RF) cavities because of its higher transition temperature and critical field compared with niobium. To meet the demand of RF test devices, the fabrication of large-area MgB 2 films on metal substrates is needed. Here, in this work, high quality MgB 2 films with 50 mm diameter were fabricated on niobium by using an improved HPCVD system at Peking University, and RF tests were carried out at SLAC National Accelerator Laboratory. The transition temperature is approximately 39.6 K and the RF surface resistance is about 120 μΩmore » at 4 K and 11.4 GHz. Finally, the fabrication processes, surface morphology, DC superconducting properties and RF tests of these large-area MgB 2 films are presented.« less
Fabrication and radio frequency test of large-area MgB 2 films on niobium substrates
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ni, Zhimao; Guo, Xin; Welander, Paul B.
Magnesium diboride (MgB 2) is a promising candidate material for superconducting radio frequency (RF) cavities because of its higher transition temperature and critical field compared with niobium. To meet the demand of RF test devices, the fabrication of large-area MgB 2 films on metal substrates is needed. Here, in this work, high quality MgB 2 films with 50 mm diameter were fabricated on niobium by using an improved HPCVD system at Peking University, and RF tests were carried out at SLAC National Accelerator Laboratory. The transition temperature is approximately 39.6 K and the RF surface resistance is about 120 μΩmore » at 4 K and 11.4 GHz. Finally, the fabrication processes, surface morphology, DC superconducting properties and RF tests of these large-area MgB 2 films are presented.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matthews, Patrick
2013-09-01
This Corrective Action Decision Document/Closure Report presents information supporting the closure of Corrective Action Unit (CAU) 105: Area 2 Yucca Flat Atmospheric Test Sites, Nevada National Security Site, Nevada. CAU 105 comprises the following five corrective action sites (CASs): -02-23-04 Atmospheric Test Site - Whitney Closure In Place -02-23-05 Atmospheric Test Site T-2A Closure In Place -02-23-06 Atmospheric Test Site T-2B Clean Closure -02-23-08 Atmospheric Test Site T-2 Closure In Place -02-23-09 Atmospheric Test Site - Turk Closure In Place The purpose of this Corrective Action Decision Document/Closure Report is to provide justification and documentation supporting the recommendation that nomore » further corrective action is needed for CAU 105 based on the implementation of the corrective actions. Corrective action investigation (CAI) activities were performed from October 22, 2012, through May 23, 2013, as set forth in the Corrective Action Investigation Plan for Corrective Action Unit 105: Area 2 Yucca Flat Atmospheric Test Sites; and in accordance with the Soils Activity Quality Assurance Plan, which establishes requirements, technical planning, and general quality practices.« less
Weaver, Richard J; Betts, Catherine; Blomme, Eric A G; Gerets, Helga H J; Gjervig Jensen, Klaus; Hewitt, Philip G; Juhila, Satu; Labbe, Gilles; Liguori, Michael J; Mesens, Natalie; Ogese, Monday O; Persson, Mikael; Snoeys, Jan; Stevens, James L; Walker, Tracy; Park, B Kevin
2017-07-01
The liver is an important target for drug-induced toxicities. Early detection of hepatotoxic drugs requires use of well-characterized test systems, yet current knowledge, gaps and limitations of tests employed remains an important issue for drug development. Areas Covered: The current state of the science, understanding and application of test systems in use for the detection of drug-induced cytotoxicity, mitochondrial toxicity, cholestasis and inflammation is summarized. The test systems highlighted herein cover mostly in vitro and some in vivo models and endpoint measurements used in the assessment of small molecule toxic liabilities. Opportunities for research efforts in areas necessitating the development of specific tests and improved mechanistic understanding are highlighted. Expert Opinion: Use of in vitro test systems for safety optimization will remain a core activity in drug discovery. Substantial inroads have been made with a number of assays established for human Drug-induced Liver Injury. There nevertheless remain significant gaps with a need for improved in vitro tools and novel tests to address specific mechanisms of human Drug-Induced Liver Injury. Progress in these areas will necessitate not only models fit for application, but also mechanistic understanding of how chemical insult on the liver occurs in order to identify translational and quantifiable readouts for decision-making.
Herald : field operational test evaluation final report
DOT National Transportation Integrated Search
2000-09-01
The Herald Field Operational Test (FOT) tested AM radio as a low-cost way to broadcast traveler information in rural areas. It tested the feasibility of broadcasting data on the inaudible portion of an existing AM broadcast. Two systems were tested, ...
Herald Field Operation Test Evaluation : Final Report
DOT National Transportation Integrated Search
2000-09-01
The Herald Field Operational Test (FOT) tested AM radio as a low-cost way to broadcast traveler information in rural areas. It tested the feasibility of broadcasting data on the inaudible portion of an existing AM broadcast. Two systems were tested, ...
PERSPECTIVE VIEW LOOKING NORTHEAST AT THE TEST STAND, NOTE THE ...
PERSPECTIVE VIEW LOOKING NORTHEAST AT THE TEST STAND, NOTE THE SERVICE AND SUPPORT BUILDINGS TO THE LEFT AND RIGHT OF THE TEST STAND. - Marshall Space Flight Center, Saturn Propulsion & Structural Test Facility, East Test Area, Huntsville, Madison County, AL
Non-susceptible landslide areas in Italy and in the Mediterranean region
NASA Astrophysics Data System (ADS)
Marchesini, I.; Ardizzone, F.; Alvioli, M.; Rossi, M.; Guzzetti, F.
2014-04-01
We used landslide information for 13 study areas in Italy and morphometric information obtained from the 3 arc-second SRTM DEM to determine areas where landslide susceptibility is expected to be null or negligible in Italy, and in the landmasses surrounding the Mediterranean Sea. The morphometric information consisted in the local terrain slope computed in a square 3 × 3 cell moving window, and in the regional relative relief computed in a circular 15 × 15 cell moving window. We tested three different models to determine the non-susceptible landslide areas, including a linear model (LR), a quantile linear model (QLR), and a quantile non-linear model (QNL). We tested the performance of the three models using independent landslide information represented by the Italian Landslide Inventory (Inventario Fenomeni Franosi in Italia - IFFI). Best results were obtained using the QNL model. The corresponding zonation of non-susceptible landslide areas was intersected in a GIS with geographical census data for Italy. The result allowed determining that 57.5% of the population of Italy (in 2001) was located in areas where landslide susceptibility is expected to be null or negligible, and that the remaining 42.5% was located in areas where some landslide susceptibility is expected. We applied the QNL model to the landmasses surrounding the Mediterranean Sea, and we tested the synoptic non-susceptibility zonation using independent landslide information for three study areas in Spain. Results proved that the QNL model was capable of determining where landslide susceptibility is expected to be negligible in the Mediterranean area. We expect our results to be applicable in similar study areas, facilitating the identification of non-susceptible and susceptible landslide areas, at the synoptic scale.
The SLS Stages Intertank Structural Test Assembly (STA) arrives at MSFC
2018-03-08
The SLS Stages Intertank Structural Test Assembly (STA) is rolling off the NASA Pegasus Barge at the MSFC Dock enroute to the MSFC 4619 Load Test Annex test facility for qualification testing via MSFC West Test Area. STA approaches Test Stand 4693, SLS LH2 test Stand, on way to Bldg. 4619
9. COLD CALIBRATION TEST STAND (H1) FROM LEFT TO RIGHT ...
9. COLD CALIBRATION TEST STAND (H-1) FROM LEFT TO RIGHT - WORK BENCH, CONTROL PANEL, CHEMICAL TANK. - Marshall Space Flight Center, East Test Area, Cold Calibration Test Stand, Huntsville, Madison County, AL
5. EAST SIDE, TEST STAND AND ITS SUPERSTRUCTURE. Edwards ...
5. EAST SIDE, TEST STAND AND ITS SUPERSTRUCTURE. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA
Flight test and evaluation of Omega navigation for general aviation
NASA Technical Reports Server (NTRS)
Hwoschinsky, P. V.
1975-01-01
A seventy hour flight test program was performed to determine the suitability and accuracy of a low cost Omega navigation receiver in a general aviation aircraft. An analysis was made of signal availability in two widely separated geographic areas. Comparison is made of the results of these flights with other navigation systems. Conclusions drawn from the test experience indicate that developmental system improvement is necessary before a competent fail safe or fail soft area navigation system is offered to general aviation.
Testing procedures for carbon fiber reinforced plastic components
NASA Technical Reports Server (NTRS)
Gosse, H. J.; Kaitatzidi, M.; Roth, S.
1977-01-01
Tests for studying the basic material are considered and quality control investigations involving preimpregnated materials (prepreg) are discussed. Attention is given to the prepreg area weight, the fiber area weight of prepregs, the resin content, volatile components, the effective thickness, resin flow, the resistance to bending strain, tensile strength, and shear strength. A description of tests conducted during the manufacturing process is also presented, taking into account X-ray methods, approaches of neutron radiography, ultrasonic procedures, resonance methods and impedance studies.
Grantham, Hedley S.; Pressey, Robert L.; Wells, Jessie A.; Beattie, Andrew J.
2010-01-01
Conservation planners represent many aspects of biodiversity by using surrogates with spatial distributions readily observed or quantified, but tests of their effectiveness have produced varied and conflicting results. We identified four factors likely to have a strong influence on the apparent effectiveness of surrogates: (1) the choice of surrogate; (2) differences among study regions, which might be large and unquantified (3) the test method, that is, how effectiveness is quantified, and (4) the test features that the surrogates are intended to represent. Analysis of an unusually rich dataset enabled us, for the first time, to disentangle these factors and to compare their individual and interacting influences. Using two data-rich regions, we estimated effectiveness using five alternative methods: two forms of incidental representation, two forms of species accumulation index and irreplaceability correlation, to assess the performance of ‘forest ecosystems’ and ‘environmental units’ as surrogates for six groups of threatened species—the test features—mammals, birds, reptiles, frogs, plants and all of these combined. Four methods tested the effectiveness of the surrogates by selecting areas for conservation of the surrogates then estimating how effective those areas were at representing test features. One method measured the spatial match between conservation priorities for surrogates and test features. For methods that selected conservation areas, we measured effectiveness using two analytical approaches: (1) when representation targets for the surrogates were achieved (incidental representation), or (2) progressively as areas were selected (species accumulation index). We estimated the spatial correlation of conservation priorities using an index known as summed irreplaceability. In general, the effectiveness of surrogates for our taxa (mostly threatened species) was low, although environmental units tended to be more effective than forest ecosystems. The surrogates were most effective for plants and mammals and least effective for frogs and reptiles. The five testing methods differed in their rankings of effectiveness of the two surrogates in relation to different groups of test features. There were differences between study areas in terms of the effectiveness of surrogates for different test feature groups. Overall, the effectiveness of the surrogates was sensitive to all four factors. This indicates the need for caution in generalizing surrogacy tests. PMID:20644726
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nacht, S.
1999-08-01
The Mercury Fire Training Pit is a former fire training area located in Area 23 of the Nevada Test Site (NTS). The Mercury Fire Training Pit was used from approximately 1965 to the early 1990s to train fire-fighting personnel at the NTS, and encompasses an area approximately 107 meters (m) (350 feet [ft]) by 137 m (450 ft). The Mercury Fire Training Pit formerly included a bermed burn pit with four small burn tanks, four large above ground storage tanks an overturned bus, a telephone pole storage area, and areas for burning sheds, pallets, and cables. Closure activities will includemore » excavation of the impacted soil in the aboveground storage tank and burn pit areas to a depth of 1.5 m (5 ft), and excavation of the impacted surface soil downgradient of the former ASTs and burnpit areas to a depth of 0.3 m (1 ft). Excavated soil will be disposed in the Area 6 Hydrocarbon Landfill at the NTS.« less
2. SOUTHEAST SIDE AND NORTHEAST REAR. SHOP BUILDING IN DISTANCE. ...
2. SOUTHEAST SIDE AND NORTHEAST REAR. SHOP BUILDING IN DISTANCE. NOTE CONCRETE PROTECTION SLAB FOR UNDERGROUND CONTROL ROOM AND ESCAPE HATCH ON GROUND AT RIGHT MIDDLE DISTANCE. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Firing Control Building, Test Area 1-100, northeast end of Test Area 1-100 Road, Boron, Kern County, CA
Roadless area-intensive management tradeoffs on the Sierra National Forest, California
Robert J. Hrubes; Kent P. Connaughton; Robert W. Sassaman
1979-01-01
This hypothesis was tested by a linear programing model: Roadless areas on the Sierra National Forest precluded from planned future development would be candidates for wilderness designation, and the associated loss in present and future timber harvests could be offset by investing in more intensive management. The results of this simulation test suggest that levels of...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-07
... of the Two-Pronged Test 2. Identification of Affected Class I Areas 3. Control Scenarios Examined 4... two-pronged test to the Transport Rule control scenario and the source-specific BART control scenario... approaches to identify the Class I areas ``affected'' by the Transport Rule as an alternative control program...
MTR WING, TRA604. BASEMENT FLOOR PLAN. FIREPROOF RECORD ROOM BELOW ...
MTR WING, TRA-604. BASEMENT FLOOR PLAN. FIRE-PROOF RECORD ROOM BELOW COUNTING ROOM. HEATING AND COOLING EQUIPMENT. UNSPECIFIED EXPANSION AREA ALONG WEST WALL. BLAW-KNOX 3150-4-1, 7/1950. INL INDEX NO. 531-0604-00-098-100007, REV. 1. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-04-01
This Closure Report summarizes the corrective actions which were completed at the Corrective Action Sites within Corrective Action Unit 211 Area 15 Farm Waste Sties at the Nevada Test Site. Current site descriptions, observations and identification of wastes removed are included on FFACO Corrective Action Site housekeeping closure verification forms.
DOE Office of Scientific and Technical Information (OSTI.GOV)
K. Ueno and J. Lstiburek
2015-09-01
Test houses with unvented roof assemblies were built to measure long-term moisture performance, in the Chicago area (5A) and the Houston area (2A). The Chicago-area test bed had seven experimental rafter bays, including a "control" vented compact roof, and six unvented roof variants with cellulose or fiberglass insulation. The interior was run at 50% RH. All roofs except the vented cathedral assembly experienced wood moisture contents and RH levels high enough to constitute failure. Disassembly at the end of the experiment showed that the unvented fiberglass roofs had wet sheathing and mold growth. In contrast, the cellulose roofs only hadmore » slight issues, such as rusted fasteners and sheathing grain raise.« less
Aquifer pumping test report for the burn site groundwater area of concern
DOE Office of Scientific and Technical Information (OSTI.GOV)
Skelly, Michael; Ferry, Robert
The Aquifer Pumping Test Report for the Burn Site Groundwater (BSG) Area of Concern is being submitted by National Technology and Engineering Solutions of Sandia, LLC and the U.S. Department of Energy (DOE)/National Nuclear Security Administration to describe the results of the aquifer pumping test program and related field activities that were completed at the BSG Area of Concern. This report summarizes the results of the field work and data analyses, and is being submitted to the New Mexico Environment Department (NMED) Hazardous Waste Bureau, as required by the April 14, 2016 letter, Summary of Agreements and Proposed Milestones Pursuantmore » to the Meeting of July 20, 2015, (NMED April 2016).« less
Issues in Language Testing Research.
ERIC Educational Resources Information Center
Oller, John W., Jr., Ed.
Practical and technical aspects of language testing research are considered in 23 articles. Topical areas include: testing of general proficiency; the hypothesis of a single unitary factor accounting for reliable variance in tests; the structure of language proficiency; pros and cons of cloze testing; a new functional testing approach; and…
Weil, Gary J.; Curtis, Kurt C.; Fakoli, Lawrence; Fischer, Kerstin; Gankpala, Lincoln; Lammie, Patrick J.; Majewski, Andrew C.; Pelletreau, Sonia; Won, Kimberly Y.; Bolay, Fatorma K.; Fischer, Peter U.
2013-01-01
Global Program to Eliminate Lymphatic Filariasis (GPELF) guidelines call for using filarial antigen testing to identify endemic areas that require mass drug administration (MDA) and for post-MDA surveillance. We compared a new filarial antigen test (the Alere Filariasis Test Strip) with the reference BinaxNOW Filariasis card test that has been used by the GPELF for more than 10 years. Laboratory testing of 227 archived serum or plasma samples showed that the two tests had similar high rates of sensitivity and specificity and > 99% agreement. However, the test strip detected 26.5% more people with filarial antigenemia (124/503 versus 98/503) and had better test result stability than the card test in a field study conducted in a filariasis-endemic area in Liberia. Based on its increased sensitivity and other practical advantages, we believe that the test strip represents a major step forward that will be welcomed by the GPELF and the filariasis research community. PMID:23690552
Khanna, Ashish; Khanna, Menka; Gill, Karamjit Singh
2015-11-01
Typhoid fever remains a significant health problem in endemic countries like India. Various serological tests for the diagnosis of typhoid fever are available commercially. We assessed the usefulness of rapid test based on magnetic particle separation to detect Immunoglobulin against Salmonella typhi O9 lipopolysaccharide. Aim of this study was to compare the sensitivity and specificity of widal test, typhidot and tubex TF test for the diagnosis of typhoid fever in an endemic country like India. Serum samples collected from 50 patients of typhoid fever, 50 patients of non typhoid fever and 100 normal healthy individuals residing in Amritsar were subjected to widal test, typhidot test and tubex TF test as per manufacturer's instructions. Data collected was assessed to find sensitivity and specificity of these tests in an endemic area. Significant widal test results were found positive in 68% of patients of typhoid fever and only 4% of non typhoid fever patients. Typhidot (IgM or IgG) was positive in 72% of typhoid fever patients and 10% and 6% in non typhoid fever and normal healthy individuals respectively. Tubex TF showed higher sensitivity of 76% and specificity of 96-99% which was higher than typhidot and comparable to widal test. This was the first evaluation of rapid tubex TF test in northern India. In countries which can afford high cost of test, tubex TF should be recommended for the diagnosis in acute stage of the disease in clinical setting. However, there is urgent need for a highly specific and sensitive test for the diagnosis of typhoid fever in clinical settings in endemic areas.
Arntzen, Kjell Arne; Schirmer, Henrik; Johnsen, Stein Harald; Wilsgaard, Tom; Mathiesen, Ellisiv B
2012-01-01
Carotid artery atherosclerosis is a major risk factor for stroke and subsequent cognitive impairment. Prospective population studies have shown associations between carotid intima-media thickness (IMT) and stenosis and cognitive decline and dementia in elderly stroke-free persons, whereas results in the middle-aged are conflicting. In this prospective population-based study, 4,371 stroke-free middle-aged participants underwent carotid ultrasound examination and assessment of vascular risk factors at baseline and were tested for cognitive function 7 years later. Associations between IMT, number of plaques and total plaque area and cognitive test scores on verbal memory test, digit symbol-coding test and tapping test were assessed in linear regression models. In the multivariable analyses adjusted for sex, age, education, depression and vascular risk factors, the presence of plaques was significantly associated with lower test scores on the verbal memory test (p = 0.01) and on the digit symbol-coding test (p = 0.03). The number of plaques (p = 0.01) and the total plaque area (p = 0.02) were associated with lower scores on the verbal memory test. No significant association was seen between common carotid artery IMT and cognitive test scores. The tapping test was not associated with the carotid ultrasound variables. In this middle-aged general population, subclinical carotid atherosclerosis measured as the presence of plaques, number of plaques and total plaque area were independent long-term predictors of lower cognitive test scores. Copyright © 2012 S. Karger AG, Basel.
Exeter, Daniel J; Moss, Lauren; Zhao, Jinfeng; Kyle, Cam; Riddell, Tania; Jackson, Rod; Wells, Susan
2015-09-01
National cardiovascular disease (CVD) guidelines recommend that adults have cholesterol levels monitored regularly. However, little is known about the extent and equity of cholesterol testing in New Zealand. To investigate the distribution and frequency of blood lipid testing by sociodemographic status in Auckland, New Zealand. We anonymously linked five national health datasets (primary care enrolment, laboratory tests, pharmaceuticals, hospitalisations and mortality) to identify adults aged ≥25 years without CVD or diabetes who had their lipids tested in 2006-2010, by age, gender, ethnicity and area of residence and deprivation. Multivariate logistic regression was used to estimate the likelihood of testing associated with these factors. Of the 627 907 eligible adults, 66.3% had at least one test between 2006 and 2010. Annual testing increased from 24.7% in 2006 to 35.1% in 2010. Testing increased with age similarly for men and women. Indian people were 87% more likely than New Zealand European and Others (NZEO) to be tested, Pacific people 8% more likely, but rates for Maori were similar to NZEO. There was marked variation within the region, with residents of the most deprived areas less likely to be tested than residents in least deprived areas. Understanding differences within and between population groups supports the development of targeted strategies for better service utilisation. While lipid testing has increased, sociodemographic variations persist by place of residence, and deprivation. Of the high CVD risk populations, lipid testing for Maori and Pacific is not being conducted according to need.
Mental Health Professional Shortage Areas in Rural Appalachia
ERIC Educational Resources Information Center
Hendryx, Michael
2008-01-01
Context: Research on health disparities in Appalachia has rarely compared Appalachia to other geographic areas in such a way as to isolate possible Appalachian effects. Purpose: This study tests hypotheses that nonmetropolitan Appalachia will have higher levels of mental health professional shortage areas than other nonmetropolitan areas of the…
140. VIEW OF CHECKOUT AREA (117), LSB (BLDG. 770), FROM ...
140. VIEW OF CHECKOUT AREA (117), LSB (BLDG. 770), FROM AGENA TRANSFER AREA SHELTER (117A). NITROGEN TEST PANEL ON EAST WALL OF AGENA TRANSFER AREA SHELTER (117A). - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA
Sharma, Vinod Kumar; Bhari, Neetu; Wadhwani, Ashok Roopchand; Bhatia, Riti
2018-02-01
Many patients with dermatitis over photo-exposed body areas are positive to many contact allergens and have a pre-existing allergic contact dermatitis. This study included patients who presented to a tertiary centre in India with dermatitis on photo-exposed body areas suspected of chronic actinic dermatitis. Their detailed histories were recorded and cutaneous and systemic examinations were performed. Patch testing was done in all the patients and photo-patch testing was carried out in 86 patients. Altogether 101 patients were included (69 males, 32 females). The most common presentation was lichenified hyperpigmented plaques on the photo-exposed sites. Photosensitivity was recorded in 64 (63%) patients and summer exacerbation in 52 (52%). Exposure to the Parthenium hysterophorus weed was recorded in 70 (69%) patients, 27 (26.7%) had a history of hair dye application and 20 (20%) had a history of atopy. Photo-patch test was positive in 11 (12.8%) patients and patch testing was positive in 71 (70%). Parthenium hysterophorus was the most common allergen implicated and was positive in three (4%) photo-patch and 52 (52%) patch tests. Other positive photo-patch test allergens were perfume mix, balsam of Peru, thiuram mix, Compositae mix and promethazine hydrochloride. Other common patch test allergens were parthenolide, colophony, fragrance mix and p-phenylenediamine (PPD) base. In the Indian population parthenium and perfume mix are the most common photoallergens in patients with dermatitis over photo-exposed areas, while parthenium, colophony, fragrance mix and PPD are the common positive allergens. © 2016 The Australasian College of Dermatologists.
Altitude Test Cell in the Four Burner Area
1947-10-21
One of the two altitude simulating-test chambers in Engine Research Building at the National Advisory Committee for Aeronautics (NACA) Lewis Flight Propulsion Laboratory. The two chambers were collectively referred to as the Four Burner Area. NACA Lewis’ Altitude Wind Tunnel was the nation’s first major facility used for testing full-scale engines in conditions that realistically simulated actual flight. The wind tunnel was such a success in the mid-1940s that there was a backlog of engines waiting to be tested. The Four Burner chambers were quickly built in 1946 and 1947 to ease the Altitude Wind Tunnel’s congested schedule. The Four Burner Area was located in the southwest wing of the massive Engine Research Building, across the road from the Altitude Wind Tunnel. The two chambers were 10 feet in diameter and 60 feet long. The refrigeration equipment produced the temperatures and the exhauster equipment created the low pressures present at altitudes up to 60,000 feet. In 1947 the Rolls Royce Nene was the first engine tested in the new facility. The mechanic in this photograph is installing a General Electric J-35 engine. Over the next ten years, a variety of studies were conducted using the General Electric J-47 and Wright Aeronautical J-65 turbojets. The two test cells were occasionally used for rocket engines between 1957 and 1959, but other facilities were better suited to the rocket engine testing. The Four Burner Area was shutdown in 1959. After years of inactivity, the facility was removed from the Engine Research Building in late 1973 in order to create the High Temperature and Pressure Combustor Test Facility.
Serological Survey of Hantavirus in Inhabitants from Tropical and Subtropical Areas of Brazil.
Alves Morais, Felipe; Pereira, Alexandre; Santo Pietro Pereira, Aparecida; Lazaro Moreli, Marcos; Marcelo Aranha Camargo, Luís; Schiavo Nardi, Marcello; Farah Tófoli, Cristina; Araujo, Jansen; Mara Dutra, Lilia; Lopes Ometto, Tatiana; Hurtado, Renata; Carmona de Jesus Maués, Fábio; Zingano Hinke, Tiene; Jaber Mahmud, Sati; Correia Lima, Monica; Tadeu Moraes Figueiredo, Luiz; Luiz Durigon, Edison
2016-01-01
Brazil has reported more than 1,600 cases of hantavirus cardiopulmonary syndrome (HPS) since 1993, with a 39% rate of reported fatalities. Using a recombinant nucleocapsid protein of Araraquara virus, we performed ELISA to detect IgG antibodies against hantavirus in human sera. The aim of this study was to analyze hantavirus antibody levels in inhabitants from a tropical area (Amazon region) in Rondônia state and a subtropical (Atlantic Rain Forest) region in São Paulo state, Brazil. A total of 1,310 serum samples were obtained between 2003 and 2008 and tested by IgG-ELISA, and 82 samples (6.2%), of which 62 were from the tropical area (5.8%) and 20 from the subtropical area (8.3%), tested positive. Higher levels of hantavirus antibody were observed in inhabitants of the populous subtropical areas compared with those from the tropical areas in Brazil.
Video Games as Psychological Tests.
ERIC Educational Resources Information Center
Jones, Marshall B.
1984-01-01
Briefly describes the characteristics of video games and discusses some advantages and disadvantages of their use to measure individual abilities. Relevant research is cited in the areas of stabilization with practice, predictive testing, performance testing, testing under extreme conditions, testing brain-injured persons, and differential…
CLOSEUP VIEW LOOKING SOUTH AT THE SATURN I TEST STAND, ...
CLOSE-UP VIEW LOOKING SOUTH AT THE SATURN I TEST STAND, NOTE THE INTERPRETIVE SIGN EXPLAINING THE HISTORIC NATURE OF THE SATURN I TEST STAND. - Marshall Space Flight Center, Saturn Propulsion & Structural Test Facility, East Test Area, Huntsville, Madison County, AL
38. 100,000 POUND STATIC TEST FACILITY: GENERAL VIEW OF TEST ...
38. 100,000 POUND STATIC TEST FACILITY: GENERAL VIEW OF TEST BAY AND EXHAUST PIT, LOOKING WEST - White Sands Missile Range, V-2 Rocket Facilities, Near Headquarters Area, White Sands, Dona Ana County, NM
37. 100,000 POUND STATIC TEST FACILITY: GENERAL VIEW OF TEST ...
37. 100,000 POUND STATIC TEST FACILITY: GENERAL VIEW OF TEST BAY AND EXHAUST PIT, LOOKING SOUTHWEST - White Sands Missile Range, V-2 Rocket Facilities, Near Headquarters Area, White Sands, Dona Ana County, NM
Kodama, M; Kodama, T; Murakami, M; Kobayashi, S; Akita, T; Nakamura, Y
1992-01-01
The association of dual steroidal disorders with breast cancer, as proposed on the basis of a case-control study in a high risk area of Japan, was tested for its validity in breast cancer patients from a low risk area of Japan. A state of glucocorticoid excess, the first hormonal trait of a breast cancer patient, was assessed using a urinary steroid parameter (a reduction of the androsterone to tetrahydrocortisol ratio by definition), and/or using a physical parameter (an elevation of the waist to hip circumference ratio by definition). Inclination to ovulation failure, the second hormonal trait, was tested using another urinary steroid parameter (a specified disorder of progestin metabolism by definition), and/or a demographic parameter (a reduction in the number of live births by definition). Results obtained are as follows: 1) premenopausal breast cancer patients from a low risk area were found to have the second trait but not the first trait, as tested using 2 parameters for each trait. 2) Postmenopausal cancer patients from a low risk area as well as pre- and post-menopausal cancer patients from a high risk area had both the 2 hormonal traits. 3) There was no discrepancy of results between any 2 test systems with the identification of 2 hormonal traits in 4 cancer patient groups. The significance of the dissociation of 2 hormonal traits, as observed in premenopausal cancer patients from a low risk area, is discussed in favor of the two-step carcinogenesis theory. Possible interaction of heredity and environment in the genesis of breast cancer is also taken into consideration.
Advanced recovery systems wind tunnel test report
NASA Technical Reports Server (NTRS)
Geiger, R. H.; Wailes, W. K.
1990-01-01
Pioneer Aerospace Corporation (PAC) conducted parafoil wind tunnel testing in the NASA-Ames 80 by 120 test sections of the National Full-Scale Aerodynamic Complex, Moffett Field, CA. The investigation was conducted to determine the aerodynamic characteristics of two scale ram air wings in support of air drop testing and full scale development of Advanced Recovery Systems for the Next Generation Space Transportation System. Two models were tested during this investigation. Both the primary test article, a 1/9 geometric scale model with wing area of 1200 square feet and secondary test article, a 1/36 geometric scale model with wing area of 300 square feet, had an aspect ratio of 3. The test results show that both models were statically stable about a model reference point at angles of attack from 2 to 10 degrees. The maximum lift-drag ratio varied between 2.9 and 2.4 for increasing wing loading.
Objective speech quality evaluation of real-time speech coders
NASA Astrophysics Data System (ADS)
Viswanathan, V. R.; Russell, W. H.; Huggins, A. W. F.
1984-02-01
This report describes the work performed in two areas: subjective testing of a real-time 16 kbit/s adaptive predictive coder (APC) and objective speech quality evaluation of real-time coders. The speech intelligibility of the APC coder was tested using the Diagnostic Rhyme Test (DRT), and the speech quality was tested using the Diagnostic Acceptability Measure (DAM) test, under eight operating conditions involving channel error, acoustic background noise, and tandem link with two other coders. The test results showed that the DRT and DAM scores of the APC coder equalled or exceeded the corresponding test scores fo the 32 kbit/s CVSD coder. In the area of objective speech quality evaluation, the report describes the development, testing, and validation of a procedure for automatically computing several objective speech quality measures, given only the tape-recordings of the input speech and the corresponding output speech of a real-time speech coder.
Test item linguistic complexity and assessments for deaf students.
Cawthon, Stephanie
2011-01-01
Linguistic complexity of test items is one test format element that has been studied in the context of struggling readers and their participation in paper-and-pencil tests. The present article presents findings from an exploratory study on the potential relationship between linguistic complexity and test performance for deaf readers. A total of 64 students completed 52 multiple-choice items, 32 in mathematics and 20 in reading. These items were coded for linguistic complexity components of vocabulary, syntax, and discourse. Mathematics items had higher linguistic complexity ratings than reading items, but there were no significant relationships between item linguistic complexity scores and student performance on the test items. The discussion addresses issues related to the subject area, student proficiency levels in the test content, factors to look for in determining a "linguistic complexity effect," and areas for further research in test item development and deaf students.
NASA Technical Reports Server (NTRS)
Cleveland, Paul; Parrish, Keith; Thomson, Shaun; Marsh, James; Comber, Brian
2016-01-01
The James Webb Space Telescope (JWST), successor to the Hubble Space Telescope, will be the largest astronomical telescope ever sent into space. To observe the very first light of the early universe, JWST requires a large deployed 6.5-meter primary mirror cryogenically cooled to less than 50 Kelvin. Three scientific instruments are further cooled via a large radiator system to less than 40 Kelvin. A fourth scientific instrument is cooled to less than 7 Kelvin using a combination pulse-tube Joule-Thomson mechanical cooler. Passive cryogenic cooling enables the large scale of the telescope which must be highly folded for launch on an Ariane 5 launch vehicle and deployed once on orbit during its journey to the second Earth-Sun Lagrange point. Passive cooling of the observatory is enabled by the deployment of a large tennis court sized five layer Sunshield combined with the use of a network of high efficiency radiators. A high purity aluminum heat strap system connects the three instrument's detector systems to the radiator systems to dissipate less than a single watt of parasitic and instrument dissipated heat. JWST's large scale features, while enabling passive cooling, also prevent the typical flight configuration fully-deployed thermal balance test that is the keystone of most space missions' thermal verification plans. This paper describes the JWST Core 2 Test, which is a cryogenic thermal balance test of a full size, high fidelity engineering model of the Observatory's 'Core' area thermal control hardware. The 'Core' area is the key mechanical and cryogenic interface area between all Observatory elements. The 'Core' area thermal control hardware allows for temperature transition of 300K to approximately 50 K by attenuating heat from the room temperature IEC (instrument electronics) and the Spacecraft Bus. Since the flight hardware is not available for test, the Core 2 test uses high fidelity and flight-like reproductions.
ERIC Educational Resources Information Center
Ministerio de Educacion, Guatemala City (Guatemala). Direccion de Bienestar Estudiantil y Educacion Especial.
This booklet presents specification tables illustrating the relative importance given to topics on tests within a particular subject area. The general subject areas are social studies, Spanish, mathematics, and natural sciences. Tables are provided for final exams in each of these areas for several primary grades, illustrating the importance of…
Extending the multimedia patient record across the wide area network.
Dayhoff, R. E.; Kuzmak, P. M.; Frank, S. A.; Kirin, G.; Saddler, C.
1996-01-01
The Dept. of Veterans Affairs is developing and testing a wide area medical network with multimedia capabilities for coordination and consolidation of medical services across locations. The system is composed of multimedia information systems at individual medical centers connected by a high speed wide area network. The DHCP Imaging System, which has been in clinical use for six years, provides storage management and workstation acquisition and display of the multimedia data. Teleconsulting capability using a variety of mechanisms' is being prototyped and tested to meet medical staffing and consultation needs. PMID:8947747
Post-Closure Inspection Report for the Tonopah Test Range, Nevada, for Calendar Year 2012
DOE Office of Scientific and Technical Information (OSTI.GOV)
NSTec Environmental Restoration
2013-01-28
This report provides the results of the annual post-closure inspections conducted at the closed Corrective Action Units (CAUs) located on the Tonopah Test Range (TTR), Nevada. This report covers calendar year 2012 and includes inspection and repair activities completed at the following CAUs: · CAU 400: Bomblet Pit and Five Points Landfill (TTR) · CAU 407: Roller Coaster RadSafe Area (TTR) · CAU 424: Area 3 Landfill Complexes (TTR) · CAU 453: Area 9 UXO Landfill (TTR) · CAU 487: Thunderwell Site (TTR)
Improving Conflict Alert Performance Using Moving Target Detector Data.
1982-06-01
2 L136 IIIII I lIlS 1 1 10 11120 125 11111I ~1.6 MICROCOPY RESOLUTION TEST CHART NATIONAL BUREAU Of SIANDARDg 19bi A DOT/FAA/RD-82/47 DOT/FAA/CT-81...Differences for Stochastic Case 23 7 Illustration of Scenarios for Warning Time Tests 30 8 Illustration of Scenarios Used for Nuisance Alert 35 Area...Nuisance Alert Area Analysis of Scenario 3 with a Target 64 Velocity of 480 Knots and SPMB= SPPB =2.8 nmi 12 Nuisance Alert Area Analysis of Scenario 3
Extending the multimedia patient record across the wide area network.
Dayhoff, R E; Kuzmak, P M; Frank, S A; Kirin, G; Saddler, C
1996-01-01
The Dept. of Veterans Affairs is developing and testing a wide area medical network with multimedia capabilities for coordination and consolidation of medical services across locations. The system is composed of multimedia information systems at individual medical centers connected by a high speed wide area network. The DHCP Imaging System, which has been in clinical use for six years, provides storage management and workstation acquisition and display of the multimedia data. Teleconsulting capability using a variety of mechanisms' is being prototyped and tested to meet medical staffing and consultation needs.
Zhang, Dapeng; Qi, Jinlei; Fu, Xiaojing; Meng, Sining; Li, Chengmei; Sun, Jiangping
2015-05-01
We sought to describe the advantage of rapid tests over ELISA tests in community-based screening for HIV among men who have sex with men (MSM) in urban areas of China. Data of 31,406 screening tests conducted over six months in 2011 among MSM across 12 areas were analyzed to compare the differences between those receiving rapid testing and ELISA. Rapid tests accounted for 45.8% of these screening tests. The rate of being screened positive was 7.2% among rapid tests and 5.3% for ELISA tests (χ(2 )= 49.161, p < 0.001). This advantage of rapid test in HIV case finding persisted even when socio-demographic, behavioural, screening recruitment channel and city were controlled for in logistic regression (exp[beta] = 1.42, p < 0.001, 95% CI = 1.27,1.59). MSM who received rapid tests, compared with those tested by ELISA, were less likely to use condoms during last anal sex (50.8% vs. 72.3%, χ(2 )= 1706.146, p < 0.001), more likely to have multiple sex partners (55.7% vs. 49.5%, χ(2 )= 238.188, p < 0.001) and less likely to have previously undergone HIV testing (38.8% vs. 54.7%, χ(2 )= 798.476, p < 0.001). These results demonstrate the robustness of the advantage of rapid tests over traditional ELISA tests in screening for MSM with HIV infection in cooperation with community-based organizations in urban settings in China. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Detection of Test Collusion via Kullback-Leibler Divergence
ERIC Educational Resources Information Center
Belov, Dmitry I.
2013-01-01
The development of statistical methods for detecting test collusion is a new research direction in the area of test security. Test collusion may be described as large-scale sharing of test materials, including answers to test items. Current methods of detecting test collusion are based on statistics also used in answer-copying detection.…
NASA Astrophysics Data System (ADS)
1984-09-01
This Test Operations Procedure (TOP) provides conventional test methods employing conventional test instrumentation for testing conventional radars. Single tests and subtests designed to test radar components, transmitters, receivers, antennas, etc., and system performance are conducted with single item instruments such as meters, generators, attenuators, counters, oscillators, plotters, etc., and with adequate land areas for conducting field tests.
Experimental thrust performance of a high-area-ratio rocket nozzle
NASA Technical Reports Server (NTRS)
Pavli, Albert J.; Kacynski, Kenneth J.; Smith, Tamara A.
1987-01-01
An experimental investigation was conducted to determine the thrust performance attainable from high-area-ratio rocket nozzles. A modified Rao-contoured nozzle with an expansion area of 1030 was test fired with hydrogen-oxygen propellants at altitude conditions. The nozzle was also tested as a truncated nozzle, at an expansion area ratio of 428. Thrust coefficient and thrust coefficient efficiency values are presented for each configuration at various propellant mixture ratios (oxygen/fuel). Several procedural techniques were developed permitting improved measurement of nozzle performance. The more significant of these were correcting the thrust for the aneroid effects, determining the effective chamber pressure, and referencing differential pressure transducers to a vacuum reference tank.
Experimental thrust performance of a high area-ratio rocket nozzle
NASA Technical Reports Server (NTRS)
Pavli, A. J.; Kacynski, K. J.; Smith, T. A.
1986-01-01
An experimental investigation was conducted to determine the thrust performance attainable from high-area-ratio rocket nozzles. A modified Rao-contoured nozzle with an expansion area of 1030 was test fired with hydrogen-oxygen propellants at altitude conditions. The nozzle was also tested as a truncated nozzle, at an expansion area ratio of 428. Thrust coefficient and thrust coefficient efficiency values are presented for each configuration at various propellant mixture ratios (oxygen/fuel). Several procedural techniques were developed permitting improved measurement of nozzle performance. The more significant of these were correcting the thrust for the aneroid effects, determining the effective chamber pressure, and referencing differential pressure transducers to a vacuum reference tank.
Compensatory mortality in mule deer populations: Technical progress report. [Odocoileus hemionus
DOE Office of Scientific and Technical Information (OSTI.GOV)
White, G.C.
1987-07-15
The hypothesis of compensatory mortality is critical to understanding population dynamics of wildlife species. This research tested for compensatory mortality in the juvenile (fawn) portion of a mule deer population. In the fall of 1986, 60 fawns were telemetered on both the control and treatment sites of the Little Hills study area. Thirteen adult females also were telemetered which, together with 31 telemetered adults already present, brought the total instrumented population to 164 at the onset of winter. Experimental manipulation to test for compensation in the population was successful, with 18% of the population on the treatment area (328 animals)more » removed. Line transect estimates of deer groups/ha were 0.12 +- 0.030 (D +- SE) for the control area and 0.14 +- 0.028 for the treatment area, giving 1727 individuals on the control area and 1490 on the treatment area. Thus the number of deer was measurably decreased on the treatment area by the removal operation.« less
Evaluation of spatial filtering on the accuracy of wheat area estimate
NASA Technical Reports Server (NTRS)
Dejesusparada, N. (Principal Investigator); Moreira, M. A.; Chen, S. C.; Delima, A. M.
1982-01-01
A 3 x 3 pixel spatial filter for postclassification was used for wheat classification to evaluate the effects of this procedure on the accuracy of area estimation using LANDSAT digital data obtained from a single pass. Quantitative analyses were carried out in five test sites (approx 40 sq km each) and t tests showed that filtering with threshold values significantly decreased errors of commission and omission. In area estimation filtering improved the overestimate of 4.5% to 2.7% and the root-mean-square error decreased from 126.18 ha to 107.02 ha. Extrapolating the same procedure of automatic classification using spatial filtering for postclassification to the whole study area, the accuracy in area estimate was improved from the overestimate of 10.9% to 9.7%. It is concluded that when single pass LANDSAT data is used for crop identification and area estimation the postclassification procedure using a spatial filter provides a more accurate area estimate by reducing classification errors.
Differential processing of binocular and monocular gloss cues in human visual cortex
Di Luca, Massimiliano; Ban, Hiroshi; Muryy, Alexander; Fleming, Roland W.
2016-01-01
The visual impression of an object's surface reflectance (“gloss”) relies on a range of visual cues, both monocular and binocular. Whereas previous imaging work has identified processing within ventral visual areas as important for monocular cues, little is known about cortical areas involved in processing binocular cues. Here, we used human functional MRI (fMRI) to test for brain areas selectively involved in the processing of binocular cues. We manipulated stereoscopic information to create four conditions that differed in their disparity structure and in the impression of surface gloss that they evoked. We performed multivoxel pattern analysis to find areas whose fMRI responses allow classes of stimuli to be distinguished based on their depth structure vs. material appearance. We show that higher dorsal areas play a role in processing binocular gloss information, in addition to known ventral areas involved in material processing, with ventral area lateral occipital responding to both object shape and surface material properties. Moreover, we tested for similarities between the representation of gloss from binocular cues and monocular cues. Specifically, we tested for transfer in the decoding performance of an algorithm trained on glossy vs. matte objects defined by either binocular or by monocular cues. We found transfer effects from monocular to binocular cues in dorsal visual area V3B/kinetic occipital (KO), suggesting a shared representation of the two cues in this area. These results indicate the involvement of mid- to high-level visual circuitry in the estimation of surface material properties, with V3B/KO potentially playing a role in integrating monocular and binocular cues. PMID:26912596
Park, Peter Y; Young, Jason
2012-03-01
An important potential benefit of a jurisdiction developing an upper-level traffic safety policy statement, such as a strategic highway safety plan (SHSP) or a traffic safety action plan, is the creation of a manageable number of focus areas, known as emphasis areas. The responsible agencies in the jurisdiction can then direct their finite resources in a systematic and strategic way designed to maximize the effort to reduce the number and severity of roadway collisions. In the United States, the federal government through AASHTO has suggested 22 potential emphasis areas. In Canada, CCMTA's 10 potential emphasis areas have been listed for consideration. This study reviewed the SHSP and traffic safety action plan of 53 jurisdictions in North America, and conducted descriptive data analyses to clarify the issues that currently affect the selection and prioritization process of jurisdiction-specific emphasis areas. We found that the current process relies heavily on high-level collision data analysis and communication among the SHSP stakeholders, but may not be the most efficient and effective way of selecting and prioritizing the emphasis areas and allocating safety improvement resources. This study then formulated a formal collision diagnosis test, known as the beta-binomial test, to clarify and illuminate the selection and the prioritization of jurisdiction-specific emphasis areas. We developed numerical examples to demonstrate how engineers can apply the proposed diagnosis test to improve the selection and prioritization of individual jurisdictions' emphasis areas. Copyright © 2011 Elsevier Ltd. All rights reserved.
Magnetotelluric Data, Northern Yucca Flat, Nevada Test Site, Nevada
DOE Office of Scientific and Technical Information (OSTI.GOV)
J.M. Williams; B.D. Rodriguez, and T.H. Asch
2005-11-23
Nuclear weapons are integral to the defense of the United States. The U.S. Department of Energy, as the steward of these devices, must continue to gauge the efficacy of the individual weapons. This could be accomplished by occasional testing at the Nevada Test Site (NTS) in Nevada, northwest of Las Vegas. Yucca Flat Basin is one of the testing areas at the NTS. One issue of concern is the nature of the somewhat poorly constrained pre-Tertiary geology and its effects on ground-water flow in the area subsequent to a nuclear test. Ground-water modelers would like to know more about themore » hydrostratigraphy and geologic structure to support a hydrostratigraphic framework model that is under development for the Yucca Flat Corrective Action Unit (CAU). During 2003, the U.S. Geological Survey (USGS) collected and processed Magnetotelluric (MT) and Audio-magnetotelluric (AMT) data at the Nevada Test Site in and near Yucca Flat to help characterize this pre-Tertiary geology. That work will help to define the character, thickness, and lateral extent of pre-Tertiary confining units. In particular, a major goal has been to define the upper clastic confining unit (UCCU) in the Yucca Flat area. Interpretation will include a three-dimensional (3-D) character analysis and two-dimensional (2-D) resistivity model. The purpose of this report is to release the MT sounding data for Profile 2, (fig. 1), located in the northern Yucca Flat area. No interpretation of the data is included here.« less
Xiao, Xiang; Wang, Tianping; Ye, Hongzhuan; Qiang, Guangxiang; Wei, Haiming; Tian, Zhigang
2005-01-01
OBJECTIVE: To determine the validity of a recently developed rapid test--a colloidal dye immunofiltration assay (CDIFA)--used by health workers in field settings to identify villagers infected with Schistosoma japonicum. METHODS: Health workers in the field used CDIFA to test samples from 1553 villagers in two areas of low endemicity and an area where S. japonicum was not endemic in Anhui, China. All the samples were then tested in the laboratory by laboratory staff using a standard parasitological method (Kato-Katz), an indirect haemagglutination assay (IHA), and CDIFA. The results of CDIFA performed by health workers were compared with those obtained by Kato-Katz and IHA. FINDINGS: Concordance between the results of CDIFA performed in field settings and in the laboratory was high (kappa index, 0.95; 95% confidence interval, 0.93-0.97). When Kato-Katz was used as the reference test, the overall sensitivity and specificity of CDIFA were 98.5% and 83.6%, respectively in the two villages in areas of low endemicity, while the specificity was 99.8% in the nonendemic village. Compared with IHA, the overall specificity and sensitivity of CDIFA were greater than 99% and 96%, respectively. With the combination of Kato-Katz and IHA as the reference standard, CDIFA had a sensitivity of 95.8% and a specificity of 99.5%, and an accuracy of 98.6% in the two areas of low endemicity. CONCLUSION: CDIFA is a specific, sensitive, and reliable test that can be used for rapid screening for schistosomiasis by health workers in field settings. PMID:16175827
Shrestha, Ram K; Sansom, Stephanie L; Richardson-Moore, April; French, P Tyler; Scalco, Beth; Lalota, Marlene; Llanas, Michelle; Stodola, James; Macgowan, Robin; Margolis, Andrew
2009-02-01
To assess the costs of rapid human immunodeficiency virus (HIV) testing and counseling to identify new diagnoses of HIV infection among jail inmates. We obtained program costs and testing outcomes from rapid HIV testing and counseling services provided in jails from March 1, 2004, through February 28, 2005, in Florida, Louisiana, New York, and Wisconsin. We obtained annual program delivery costs-fixed and variable costs-from each project area. We estimated the average cost of providing counseling and testing to HIV-negative and HIV-infected inmates and estimated the cost per newly diagnosed HIV infection. In the 4 project areas, 17,433 inmates (range, 2185-6463) were tested: HIV infection was diagnosed for 152 inmates (range, 4-81). The average cost of testing ranged from $29.46 to $44.98 for an HIV-negative inmate and from $71.37 to $137.72 for an HIV-infected inmate. The average cost per newly diagnosed HIV infection ranged from $2,451 to $25,288. Variable costs were 61% to 86% of total costs. The cost of identifying jail inmates with newly diagnosed HIV infection by using rapid HIV testing varied according to the prevalence of undiagnosed HIV infection among inmates tested in project areas. Variations in the cost of testing HIV-negative and HIV-infected inmates were because of the differences in wages, travel to the jails, and the amount of time spent on counseling and testing. Program managers can use these data to gauge the cost of initiating counseling and testing programs in jails or to streamline current programs.
32. VIEW LOOKING EAST AT THE STATIC TEST TOWER WHILE ...
32. VIEW LOOKING EAST AT THE STATIC TEST TOWER WHILE A JUPITER MISSILE IS BEING POSITIONED ONTO THE TEST TOWER. DATE AND PHOTOGRAPHER UNKNOWN, MSFC PHOTO LAB. - Marshall Space Flight Center, Saturn Propulsion & Structural Test Facility, East Test Area, Huntsville, Madison County, AL
DOE Office of Scientific and Technical Information (OSTI.GOV)
David A. Strand
2004-06-01
This Corrective Action Investigation Plan (CAIP) contains project-specific information for conducting site investigation activities at Corrective Action Unit (CAU) 151: Septic Systems and Discharge Area, Nevada Test Site, Nevada. Information presented in this CAIP includes facility descriptions, environmental sample collection objectives, and criteria for the selection and evaluation of environmental corrective action alternatives. Corrective Action Unit 151 is located in Areas 2, 12, 18, and 20 of the Nevada Test Site, which is 65 miles northwest of Las Vegas, Nevada. Corrective Action Unit 151 is comprised of the nine Corrective Action Sites (CAS) listed below: (1) 02-05-01, UE-2ce Pond; (2)more » 12-03-01, Sewage Lagoons (6); (3) 12-04-01, Septic Tanks; (4) 12-04-02, Septic Tanks; (5) 12-04-03, Septic Tank; (6) 12-47-01, Wastewater Pond; (7) 18-03-01, Sewage Lagoon; (8) 18-99-09, Sewer Line (Exposed); and (9) 20-19-02, Photochemical Drain. The CASs within CAU 151 are discharge and collection systems. Corrective Action Site 02-05-01 is located in Area 2 and is a well-water collection pond used as a part of the Nash test. Corrective Action Sites 12-03-01, 12-04-01, 12-04-02, 12-04-03, and 12-47-01 are located in Area 12 and are comprised of sewage lagoons, septic tanks, associated piping, and two sumps. The features are a part of the Area 12 Camp housing and administrative septic systems. Corrective Action Sites 18-03-01 and 18-99-09 are located in the Area 17 Camp in Area 18. These sites are sewage lagoons and associated piping. The origin and terminus of CAS 18-99-09 are unknown; however, the type and configuration of the pipe indicates that it may be a part of the septic systems in Area 18. Corrective Action Site 20-19-02 is located in the Area 20 Camp. This site is comprised of a surface discharge of photoprocessing chemicals.« less
Seattle wide-area information for travelers (SWIFT) : architecture study
DOT National Transportation Integrated Search
1998-10-19
The SWIFT (Seattle Wide-area Information For Travelers) Field Operational Test was intended to evaluate the performance of a large-scale urban Advanced Traveler Information System (ATIS) deployment in the Seattle area. The unique features of the SWIF...
Non-susceptible landslide areas in Italy and in the Mediterranean region
NASA Astrophysics Data System (ADS)
Marchesini, I.; Ardizzone, F.; Alvioli, M.; Rossi, M.; Guzzetti, F.
2014-08-01
We used landslide information for 13 study areas in Italy and morphometric information obtained from the 3-arcseconds shuttle radar topography mission digital elevation model (SRTM DEM) to determine areas where landslide susceptibility is expected to be negligible in Italy and in the landmasses surrounding the Mediterranean Sea. The morphometric information consisted of the local terrain slope which was computed in a square 3 × 3-cell moving window, and in the regional relative relief computed in a circular 15 × 15-cell moving window. We tested three different models to classify the "non-susceptible" landslide areas, including a linear model (LNR), a quantile linear model (QLR), and a quantile, non-linear model (QNL). We tested the performance of the three models using independent landslide information presented by the Italian Landslide Inventory (Inventario Fenomeni Franosi in Italia - IFFI). Best results were obtained using the QNL model. The corresponding zonation of non-susceptible landslide areas was intersected in a geographic information system (GIS) with geographical census data for Italy. The result determined that 57.5% of the population of Italy (in 2001) was located in areas where landslide susceptibility is expected to be negligible. We applied the QNL model to the landmasses surrounding the Mediterranean Sea, and we tested the synoptic non-susceptibility zonation using independent landslide information for three study areas in Spain. Results showed that the QNL model was capable of determining where landslide susceptibility is expected to be negligible in the validation areas in Spain. We expect our results to be applicable in similar study areas, facilitating the identification of non-susceptible landslide areas, at the synoptic scale.
Relationship between echotextural and histomorphometric characteristics of stallion testes.
Pozor, Malgorzata; Morrissey, Heather; Albanese, Valeria; Khouzam, Natalie; Deriberprey, Alexis; Macpherson, Margo L; Kelleman, Audrey A
2017-09-01
The goal of this study was to investigate correlations between objective measures of testicular echotexture and histomorphometric attributes related to the histological composition of stallion testes. Fifty-four scrotal testes were obtained from three groups of stallions during routine castrations: colts <1 yr old (n = 18), young stallions 1-5 yrs old (n = 27), mature stallions > 5 yrs old (n = 9). In addition, two scrotal testes with degeneration, 16 retained inguinal and 10 retained abdominal testes were surgically obtained. Cross-sectional and longitudinal ultrasonograms were obtained for each testis. Mean numerical pixel values (NPVs) as well as pixel standard deviations (PSDs) were determined for each image (ImageJ-1.5 software). Histomorphometric attributes of the seminiferous tubules (STs) were derived (three tissue samples per each testis) using image analysis software [relative STs area: RSTA = ST area/total cross-sectional area (TA) x 100%; relative STs lumen: RSTL = ST lumen area/TA x 100%; individual ST area; ISTA; individual ST lumen: ISTL; seminiferous epithelium height: SHE]. Degree of fibrosis was graded semi-quantitatively (0-3) in samples from 17 testes. All measures of testicular echotexture as well as all histomorphometric attributes of STs had highest values when obtained from the scrotal testes of young and mature stallions (P < 0.05). The NPVs and PSDs from the ultrasonographic images of the scrotal testes were significantly correlated with all histomorphometric attributes of STs (P < 0.001). However, there was no correlation between the majority of these measures and attributes if each group of the scrotal testes was analyzed separately. The NPVs from the ultrasonographic images of the retained inguinal testes were correlated with RSTA, RSTL, ISTA, and ISTL, while the NPVs from the retained abdominal testes were not correlated with any of the histomorphometric attributes of the STs. Testes with high degree of fibrosis had variable values of pixel intensity and pixel heterogeneity. Based on the results of this study, we concluded that the pixel intensity and pixel heterogeneity of stallion testes increase during the first year of life and remain stable in young and mature stallions. These changes occur in parallel to the development of the seminiferous tubules. Testicular echogenicity in stallions does not seem to reflect degree of testicular fibrosis. Retained abdominal testes have lower and less heterogeneous echogenicity than scrotal testes from stallions that are more than one year old. While pixel analysis cannot replace biopsy in assessing testicular histomorphology in young and mature stallions, testicular echogenicity is a good indicator of peri-pubertal growth and expansion of the seminiferous tubules. Copyright © 2017. Published by Elsevier Inc.
John G. Michopoulos; John Hermanson; Athanasios Iliopoulos
2014-01-01
The research areas of mutiaxial robotic testing and design optimization have been recently utilized for the purpose of data-driven constitutive characterization of anisotropic material systems. This effort has been enabled by both the progress in the areas of computers and information in engineering as well as the progress in computational automation. Although our...
Summary of Research 2000: Department of Oceanography
2001-12-01
Castro, R., A. S. Mascarenhas, R. Durazo and C. Collins, "Variaci6n estacional de la temperatura y salinidad en la entrada del Golfo de California...AREAS: Sensors , Battlespace Environments KEYWORDS: Littoral, Acoustics, Nowcast, Shelfbreak Fronts NAVAL POSTGRADUATE SCHOOL OAO TEST-BAN TREATY...Organization. DoD KEY TECHNOLOGY AREAS: Sensors KEYWORDS: Nuclear Test-Ban Treaty Monitoring OCEAN ACOUSTIC FEDERATION: CALIFORNIA CURRENT MONITORING
9. AERIAL VIEW LOOKING NORTH AT THE GEORGE C. MARSHALL ...
9. AERIAL VIEW LOOKING NORTH AT THE GEORGE C. MARSHALL SPACE FLIGHT CENTER. DODD ROAD RUNS DOWN THE CENTER OF THE PHOTO. THE EAST TEST AREA IS TOWARDS THE BOTTOM OF THE PHOTO, FABRICATION, ENGINEERING AND ADMINISTRATION NEAR THE TOP OF THE PHOTO. 1961, MSFC PHOTO LAB. - Marshall Space Flight Center, East Test Area, Dodd Road, Huntsville, Madison County, AL
ERIC Educational Resources Information Center
Ferng, Shiaw-Fen; Lawson, Jay K.
1996-01-01
Results of a study in Boone County, Indiana--a high radon potential geographic area--show that residents' knowledge about radon is at a relatively superficial level. A significant correlation between radon knowledge and home radon tests is observed. Respondents chose the newspaper as the favorite medium through which to launch radon health…
An Investigation of Selected Variables Related to Student Algebra I Performance in Mississippi
ERIC Educational Resources Information Center
Scott, Undray
2016-01-01
This research study attempted to determine if specific variables were related to student performance on the Algebra I subject-area test. This study also sought to determine in which of grades 8, 9, or 10 students performed better on the Algebra I Subject Area Test. This study also investigated the different criteria that are used to schedule…
MTRETR MAINTENANCE SHOP, TRA653. FLOOR PLAN FOR MEZZANINE: LUNCH AND ...
MTR-ETR MAINTENANCE SHOP, TRA-653. FLOOR PLAN FOR MEZZANINE: LUNCH AND CONFERENCE ROOM, STORAGE AREA, OFFICES FOR FOREMEN, STENOS, ENGINEERS, DISPATCHER, WOMEN'S RESTROOM. HUMMEL HUMMEL & JONES 810-MTR-ETR-653-A-12, 2/1958. INL INDEX NO. 532-0653-00-381-102837, REV. 3. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Aquifer test results, Green Swamp area, Florida
Tibbals, C.H.; Grubb, Hayes F.
1982-01-01
An aquifer test conducted in the Green Swamp area December 15-16 , 1975 was designed to stress the uppermost part of the Floridan aquifer so that the leakage characteristics of the overlying confining bed could be determined. A well tapping the upper part of the Floridan aquifer was pumped at a rate of about 1,040 gallons per minute for 35 hours; drawdown was measured in the Floridan aquifer and in two horizons in the confining bed. Analysis of the data indicates that the transmissivity of the uppper 160 feet of the Floridan is 13,000 square feet per day, the storage coefficient is about 0.0002.5, and the overlying confining bed leakance coefficient is about 0.02 to 0.025 per day. The vertical hydraulic diffusivity of the confining bed ranged from 610 square feet per day to 16,000 square feet per day. Results of the test indicate that, in the area of the test site, a Floridan aquifer well field would induce additional recharge to the Floridan. As a result of that increased recharge , water levels in the surficial aquifer would tend to stand lower, runoff from the area would tend to be less, and, perhaps, evapotranspiration would be less than normal.(USGS)
Drilling a deep geologic test well at Hilton Head Island, South Carolina
Schultz, Arthur P.; Seefelt, Ellen L.
2011-01-01
The U.S. Geological Survey, in cooperation with the South Carolina Department of Health and Environmental Control (SCDHEC), is drilling a deep geologic test well at Hilton Head Island, S.C. The test well is scheduled to run between mid-March and early May 2011. When completed, the well will be about 1,000 feet deep. The purpose of this test well is to gain knowledge about the regional-scale Floridan aquifer, an important source of groundwater in the Hilton Head area. Also, cores obtained during drilling will enable geologists to study the last 60 million years of Earth history in this area.
1967-09-09
This photograph depicts the F-1 engine firing in the Marshall Space Flight Center’s F-1 Engine Static Test Stand. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. It is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base, designed to assist in the development of the F-1 Engine. Capability is provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. The foundation of the stand is keyed into the bedrock approximately 40 feet below grade.
Advanced Combustor in the Four Burner Area
1966-03-21
Engineer Frank Kutina and a National Aeronautics and Space Administration (NASA) mechanic examine the setup of an advanced combustor rig inside one of the test cells at the Lewis Research Center’s Four Burner Area in the Engine Research Building. Kutina, of the Research Operations Branch, served as go-between for the researchers and the mechanics. He helped develop the test configurations and get the hardware installed. At the time of this photograph, Lewis Center Director Abe Silverstein had just established the Airbreathing Engine Division to address the new propulsion of the 1960s. After nearly a decade of focusing almost exclusively on space, NASA Lewis began tackling issues relating to the new turbofan engine, noise reduction, energy efficiency, supersonic transport, and the never-ending quest for higher performance levels with smaller and more lightweight engines. The Airbreathing Engine Division’s Combustion Branch was dedicated to the study and mitigation of the high temperatures and pressures found in advanced combustor designs. These high temperatures and pressures could destroy engine components. The Lewis investigation included film cooling, diffuser flow, and jet mixing. Components were tested in smaller test cells, but a full-scale augmenting burner rig, seen here, was tested extensively in the Four Burner Area test cell.
More, D R; Napoli, D C; Hagan, L L
2003-06-01
The use of herbal supplements is common, yet little is known about their pharmacologic properties. The purpose of this study was to assess the effects of 23 commonly used herbal supplements on histamine skin prick testing (SPT). Fifteen healthy volunteers participated in a double-blind, placebo-controlled, single-dose, crossover study. Wheal and flare responses to SPT with histamine phosphate (1 mg/ml) were measured before and 4 h after administration of each of the 23 popular herbal supplements, fexofenadine (60 mg) and placebo. Wheal and flare areas were recorded with tracings performed 10 min after the prick test and measured with a PC-digitizer using stereometric software. Fexofenadine significantly suppressed the wheal (P < 0.001) and flare (P = 0.02) areas compared with placebo. None of the herbal supplements caused significant suppression of the wheal and flare areas compared with placebo (P > 0.10). When taken in single-doses, the popular herbal supplements tested did not significantly affect the histamine skin response. Therefore, it seems unnecessary for clinicians to ask patients to discontinue these herbal supplements prior to allergy skin testing.
Magnetotelluric Data, Rainier Mesa/Shoshone Mountain, Nevada Test Site, Nevada.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jackie M. Williams; Jay A. Sampson; Brian D. Rodriguez
2006-11-03
The United States Department of Energy (DOE) and the National Nuclear Security Administration (NNSA) at their Nevada Site Office (NSO) are addressing ground-water contamination resulting from historical underground nuclear testing through the Environmental Management (EM) program and, in particular, the Underground Test Area (UGTA) project. From 1951 to 1992, 828 underground nuclear tests were conducted at the Nevada Test Site northwest of Las Vegas. Most of these tests were conducted hundreds of feet above the ground-water table; however, more than 200 of the tests were near or within the water table. This underground testing was limited to specific areas ofmore » the Nevada Test Site, including Pahute Mesa, Rainier Mesa/Shoshone Mountain, Frenchman Flat, and Yucca Flat. One issue of concern is the nature of the somewhat poorly constrained pre-Tertiary geology, and its effects on ground-water flow. Ground-water modelers would like to know more about the hydrostratigraphy and geologic structure to support a hydrostratigraphic framework model that is under development for the Rainier Mesa/Shoshone Mountain Corrective Action Unit (Bechtel Nevada, 2006). During 2005, the U.S. Geological Survey (USGS), in cooperation with the DOE and NNSA-NSO, collected and processed data from twenty-six magnetotelluric (MT) and audio-magnetotelluric (AMT) sites at the Nevada Test Site. The 2005 data stations were located on and near Rainier Mesa and Shoshone Mountain to assist in characterizing the pre-Tertiary geology in those areas. These new stations extend the area of the hydrogeologic study previously conducted in Yucca Flat. This work will help refine what is known about the character, thickness, and lateral extent of pre-Tertiary confining units. In particular, a major goal has been to define the upper clastic confining unit (UCCU – late Devonian to Mississippian-age siliciclastic rocks assigned to the Eleana Formation and Chainman Shale) from the Yucca Flat area and west towards Shoshone Mountain, to Buckboard Mesa in the south, and onto Rainier Mesa in the north. Subsequent interpretation will include a three-dimensional (3-D) character analysis and a two-dimensional (2-D) resistivity model. The purpose of this report is to release the MT sounding data for the twenty-six stations shown in figure 1. No interpretation of the data is included here.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stauffer, Philip H.; Rahn, Thomas A.; Ortiz, John Philip
Here we describe results from a tracer test in the Cerros del Rio basalt beneath Mesita del Buey, Technical Area 54 (TA-54) at Los Alamos National Laboratory (LANL or the Laboratory). This report follows from plans outlined in our previous Tracer Test Work Plan (LANL 2016). These activities were conducted by LANL to further characterize subsurface properties of the Cerros del Rio basalts at Material Disposal Area (MDA) L (Figure 1.1-1). The work presented follows from the “Interim Measures Work Plan for Soil-Vapor Extraction of Volatile Organic Compounds from Material Disposal Area L, Technical Area 54, Revision 1,” submitted tomore » the New Mexico Environment Department (NMED) in September 2014 (LANL 2014). Remediation of the MDA L vapor plume by soil-vapor extraction (SVE) is recommended as part of the final remedy in the “Corrective Measures Evaluation Report for Material Disposal Area L, Solid Waste Management Unit 54-006, at Technical Area 54, Revision 2” to meet a remedial action objective of preventing groundwater from being impacted above a regulatory standard by the transport of volatile organic compounds (VOCs) to groundwater through soil vapor (LANL 2011).« less
Senior, Lisa A.; Cinotto, Peter J.; Conger, Randall W.; Bird, Philip H.; Pracht, Karl A.
2005-01-01
Ground water in the vicinity of various industrial facilities in Upper Gwynedd Township and Lansdale Borough, Montgomery County, Pa., is contaminated with various volatile organic compounds (VOCs). The 2-square-mile area was placed on the National Priorities List as the North Penn Area 7 Superfund site by the U.S. Environmental Protection Agency (USEPA) in 1989. The U.S. Geological Survey (USGS) conducted geophysical logging, aquifer testing, water-level monitoring, and streamflow measurements in the vicinity of North Penn Area 7 beginning autumn 2000 to assist the USEPA in developing an understanding of the hydrogeologic framework in the area as part of the USEPA Remedial Investigation. The study area is underlain by Triassic and Jurassic-age sandstones, siltstones, and shales of the Lockatong Formation and the Brunswick Group. Regionally, these rocks strike northeast and dip to the northwest. The sequence of rocks form a fractured-sedimentary-rock aquifer that acts as a set of confined to partially confined layered aquifers of differing permeabilities. The aquifers are recharged by precipitation and discharge to streams and wells. The Wissahickon Creek headwaters are less than 1 mile northeast of the study area, and this stream flows southwest to bisect North Penn Area 7. Ground water is pumped in the vicinity of North Penn Area 7 for industrial use and public supply. The USGS collected geophysical logs for 16 wells that ranged in depth from 50 to 623 feet. Aquifer-interval-isolation testing was done in 9 of the 16 wells, for a total of 30 zones tested. A multiple-well aquifer test was conducted by monitoring the response of 14 wells to pumping a 600-ft deep production well in February and March 2002. In addition, water levels were monitored continuously in three wells in the area and streamflow was measured quarterly at two sites on Wissahickon Creek from December 2000 through September 2002. Geophysical logging identified water-bearing zones associated with high-angle fractures and bedding-plane openings throughout the depth of the boreholes. Heatpulse-flowmeter measurements under nonpumping, ambient conditions indicated that borehole flow, where detected, was in the upward direction in three of the eight wells and in the downward direction in three wells. In two wells, both upward and downward flow were measured. Heatpulse-flowmeter measurements under pumping conditions were used to identify the most productive intervals in wells. Correlation of natural-gamma-ray and single-point-resistance logs indicated that bedding in the area probably strikes about 40 degrees northeast and dips from 6 to 7 degrees northwest. Aquifer intervals isolated by inflatable packers in wells were pumped to test productivity and to collect samples to determine chemical quality of water produced from the interval. Interval-isolation testing confirmed the presence of vertical hydraulic gradients indicated by heatpulse-flowmeter measurements. The specific capacities of isolated intervals ranged over two orders of magnitude, from 0.02 to more than 3.6 gallons per minute per foot. Intervals adjacent to isolated pumped intervals showed little response to pumping the isolated zone. The presence of vertical hydraulic gradients and lack of adjacent-interval response to pumping in isolated intervals indicate a limited degree of vertical hydraulic connection between the aquifer intervals tested. Concentrations of most VOC contaminants generally were highest in well-water samples from the shallowest isolated intervals, with some exceptions. Trichloroethylene, cis-1,2-dichloroethylene, and toluene were the most frequently detected VOCs, with maximum concentrations of greater than 340, 680, and greater than 590 micrograms per liter, respectively. Results of the aquifer test with multiple observation wells showed that water levels in 4 of the 14 wells declined in response to pumping. The four wells that responded to pumping are either along str
A Comparison of Lord's Chi Square and Raju's Area Measures in Detection of DIF.
ERIC Educational Resources Information Center
Cohen, Allan S.; Kim, Seock-Ho
1993-01-01
The effectiveness of two statistical tests of the area between item response functions (exact signed area and exact unsigned area) estimated in different samples, a measure of differential item functioning (DIF), was compared with Lord's chi square. Lord's chi square was found the most effective in determining DIF. (SLD)
Western Aeronautical Test Range (WATR) mission control Blue room
1994-12-05
Mission control Blue Room, seen here, in building 4800 at NASA's Dryden Flight Research Center, is part of the Western Aeronautical Test Range (WATR). All aspects of a research mission are monitored from one of two of these control rooms at Dryden. The WATR consists of a highly automated complex of computer controlled tracking, telemetry, and communications systems and control room complexes that are capable of supporting any type of mission ranging from system and component testing, to sub-scale and full-scale flight tests of new aircraft and reentry systems. Designated areas are assigned for spin/dive tests, corridors are provided for low, medium, and high-altitude supersonic flight, and special STOL/VSTOL facilities are available at Ames Moffett and Crows Landing. Special use airspace, available at Edwards, covers approximately twelve thousand square miles of mostly desert area. The southern boundary lies to the south of Rogers Dry Lake, the western boundary lies midway between Mojave and Bakersfield, the northern boundary passes just south of Bishop, and the eastern boundary follows about 25 miles west of the Nevada border except in the northern areas where it crosses into Nevada.
THE DISTRIBUTION OF COCCIDIOIDOMYCOSIS IN SOUTHERN CALIFORNIA
Kessel, John F.; Biddle, Marjorie; Tucker, Harold A.; Yeaman, Antoinette
1950-01-01
In coccidioidin skin test surveys among persons of high school age in Saugus, Canoga Park, Banning and Palm Springs areas the average incidence of positive reaction was 15 per cent. Although considerably less than the 68 per cent incidence reported among high school students of Kern County, it is high enough to indicate pockets of relatively high endemicity in Southern California below the San Joaquin Valley. Histoplasmin tests were performed on most of the persons tested with coccidioidin in this survey. The over-all incidence of positive reaction in the group was 7.6 per cent. Most of the subjects with positive reaction to histoplasmin gave a history of having previously lived in some area in the central United States where histoplasmosis is known to be endemic. A few subjects who had positive reaction to coccidioidin tests and who had lived in areas known to be endemic for coccidioidomycosis but not for histoplasmosis, also had positive reaction to histoplasmin. However, the induration produced was always smaller than that caused by the coccidioidin reaction, and there was minimal confusion in interpreting the tests. PMID:14772654
Western Aeronautical Test Range (WATR) mission control Gold room
NASA Technical Reports Server (NTRS)
1990-01-01
Mission control Gold room is seen here, located at the Dryden Flight Research Center of the Western Aeronautical Test Range (WATR). All aspects of a research mission are monitored from one of two of these control rooms at Dryden. The WATR consists of a highly automated complex of computer controlled tracking, telemetry, and communications systems and control room complexes that are capable of supporting any type of mission ranging from system and component testing, to sub-scale and full-scale flight tests of new aircraft and reentry systems. Designated areas are assigned for spin/dive tests, corridors are provided for low, medium, and high-altitude supersonic flight, and special STOL/VSTOL facilities are available at Ames Moffett and Crows Landing. Special use airspace, available at Edwards, covers approximately twelve thousand square miles of mostly desert area. The southern boundary lies to the south of Rogers Dry Lake, the western boundary lies midway between Mojave and Bakersfield, the northern boundary passes just south of Bishop, and the eastern boundary follows about 25 miles west of the Nevada border except in the northern areas where it crosses into Nevada.
Rift Valley fever on the east coast of Madagascar.
Morvan, J; Saluzzo, J F; Fontenille, D; Rollin, P E; Coulanges, P
1991-01-01
In March 1990, a Rift Valley fever virus (RVFV) outbreak was suspected in the district of Fenerive on the east coast of Madagascar after an abnormally high incidence of abortions and disease in livestock. Sera from humans and cattle were tested for RVFV antibodies by immunofluorescence assay (IFA) and ELISA-IgM capture. Sera and mosquitoes collected in the same area were tested for virus isolation by tissue culture and suckling mouse intracerebral inoculation, and for antigen detection by an ELISA antigen capture assay. Among cattle from the area, RVFV antibody prevalence was 58.6% by IFA and 29.6% by ELISA-IgM. In contrast, human populations in the same area had a lower RVFV antibody prevalence, with 8.01% IFA and 5.4% IgM-positive sera. No RVFV antigen was detected and virus isolation was unsuccessful from the sera and mosquito pools tested. Different hypotheses concerning the emergence and diffusion of RVFV in this area and the occurrence of the outbreak are discussed.
Aging and quality of life of elderly people in rural areas.
Garbaccio, Juliana Ladeira; Tonaco, Luís Antônio Batista; Estêvão, Wilson Goulart; Barcelos, Bárbara Jacome
2018-01-01
To evaluate the quality of life and health of elderly in rural areas of Minas Gerais State's center-west. Cross-sectional study, in four municipalities of Minas Gerais State, by interviewing elderly people. Associations between socio-demographic and quality of life variables were tested, separated into "satisfactory"/"unsatisfactory" with values from the median of positive answers. It was used the chi-square test, Fisher's test and regression. 182 elderly answered the questions and showed a relation with the "satisfactory" quality of life - bivariate (p < 0.05): age by 69 years (61.6%), married (61.7%), living by 54 years in rural areas (68%), with no financial support (59.5%), living with someone else (61%), non-smoker (60%), presenting good health (76.7%), satisfied with life (69.6%); regression: not having financial support, living with someone else and not smoking. Elderly people in rural areas present good quality of life/health in the cognitive aspect, access to services, goods, habits, but awareness must be constant due to their weakness.
Evaluation of Internal Brushing on Pinch Weld Quality
DOE Office of Scientific and Technical Information (OSTI.GOV)
Korinko, P
2005-12-01
Post machining operations such as borescope inspection can cause linear indications down the length of the bore of fill stems. Often these indications are removed or obscured using rotary wire brushing. This study evaluated the effect this mechanical operation may have on pinch weld quality when relatively cold welds were made. A total of four stems with two levels of brushing of both Type 304L and 21-6-9 stainless steels were tested. In addition, two each of the Type 304L stems were Nitradd cleaned and the other two were aqueously cleaned; all four 21-6-9 stems were aqueously cleaned. All of themore » brushed stem areas exhibited more surface anomalies based on borescope evaluation. On average, the bond rating was a higher value (worse) for the brushed areas than the unadulterated areas for both Type 304L and 21-6-9 stems. The test method used may have biased the results towards a lesser quality bond for the brushed areas so additional testing is recommended.« less
Pharmacogenomics in diverse practice settings: implementation beyond major metropolitan areas
Dorfman, Elizabeth H; Trinidad, Susan Brown; Morales, Chelsea T; Howlett, Kevin; Burke, Wylie; Woodahl, Erica L
2015-01-01
Aim The limited formal study of the clinical feasibility of implementing pharmacogenomic tests has thus far focused on providers at large medical centers in urban areas. Our research focuses on small metropolitan, rural and tribal practice settings. Materials & methods We interviewed 17 healthcare providers in western Montana regarding pharmacogenomic testing. Results Participants were optimistic about the potential of pharmacogenomic tests, but noted unique barriers in small and rural settings including cost, adherence, patient acceptability and testing timeframe. Participants in tribal settings identified heightened sensitivity to genetics and need for community leadership approval as additional considerations. Conclusion Implementation differences in small metropolitan, rural and tribal communities may affect pharmacogenomic test adoption and utilization, potentially impacting many patients. PMID:25712186
Evaluation of serum immunoglobulins among individuals living near six Superfund sites.
Williamson, Dhelia M; White, Mary C; Poole, Charles; Kleinbaum, David; Vogt, Robert; North, Kari
2006-07-01
Residents living in communities near Superfund sites have expressed concern that releases from these facilities affect their health, including adverse effects on their immune systems. We used data from six cross-sectional studies to evaluate whether people who live near several Superfund sites are more likely to have individual immunoglobulin test results (IgA, IgG, and IgM) below or above the reference range than those who live in comparison areas with no Superfund site. Study participants consisted of target-area residents who lived close to a Superfund site and comparison-area residents who were not located near any Superfund or hazardous waste sites. A consistent modeling strategy was used across studies to assess the magnitude of the relationship between area of residence and immunoglobulin test results, adjusting for potential confounders and effect modifiers. In all study areas, the results suggest that people who live near a Superfund site may have been more likely to have IgA test results above the reference range than comparison areas residents regardless of modeling strategy employed. The effect measures were larger for residents who lived in communities near military bases with groundwater contamination. For all analyses the wide confidence intervals reflect uncertainty in the magnitude of these effects. To adequately address the question of whether the immune system is affected by low-level exposures to hazardous substances, we recommend that more functional immunotoxicity tests be conducted in human populations where individual exposure information is available or when it can be reasonably estimated from environmental exposure measurements.
Habitat islands and the equilibrium theory of island biogeography: testing some predictions
Brown, M.; Dinsmore, J.J.
1988-01-01
Species-area data from a study of marsh birds are used to test five predictions generated by the equilibrium theory of island biogeography. Three predictions are supported: we found a significant species-area relationship, a non-zero level of turnover, and a variance-mean ratio of 0.5. One prediction is rejected: the extinction rates were not greater on small islands. The results of one test are equivocal: the number of species on each island was not always the same. As Gilbert (1980) suggests, a strong species-area relationship alone does not validate the theory. The avian communities we studied were on habitat islands, not true islands, and underwent complete extinction annually. Thus caution must be used before applying the theory to these and other habitat islands.
Microcystic Variant of an Intraosseous Meningioma in the Frontal Area: A Case Report
2014-01-01
Meningiomas located inside the bone of the calvaria belong to the group of rare types of tumours. The microcystic variant is the least common in this area. Due to their similarity to other tumours in this area, the imaging test of those tumours may constitute the source of an improper preoperative diagnosis. According to the records of the Department of Neurosurgery in Bielsko-Biała, 133 patients diagnosed with an intracranial meningioma confirmed by a histopathological test were operated in the last 10 years (2004–2014). In the histopathological test, three patients were diagnosed with the microcystic variant, which constitutes 2.25% of the cases. Only one variant of microcystic meningioma was located inside the bone, which constitutes 0.75% of all the meningiomas operated. PMID:25031877
GENERAL VIEW LOOKING SOUTH AT THE SATURN I STATIC TEST ...
GENERAL VIEW LOOKING SOUTH AT THE SATURN I STATIC TEST STAND. NOTE THE FIRST STAGE OF THE SATURN I ROCKET ON DISPLAY TO THE LEFT OF THE TEST STAND. - Marshall Space Flight Center, Saturn Propulsion & Structural Test Facility, East Test Area, Huntsville, Madison County, AL
He, Chang-hua; Hu, Xi-min; Wang, Guang-ze; Zhao, Wei; Sun, Ding-wei; Li, Yu-chun; Chen, Chun-xiang; Du, Jian-wei; Wang, Shan-qing
2014-07-13
In the island of Hainan, the great majority of malaria cases occur in mountain worker populations. Using the behavioral change communication (BCC) strategy, an interventional study was conducted to promote mountain worker malaria prevention at a test site. This study found the methods and measures that are suitable for malaria prevention among mountain worker populations. During the Plasmodium falciparum elimination stage in Hainan, a representative sampling method was used to establish testing and control sites in areas of Hainan that were both affected by malaria and had a relatively high density of mountain workers. Two different methods were used: a BCC strategy and a conventional strategy as a control. Before and after the intervention, house visits, core group discussions, and structural surveys were utilized to collect qualitative and quantitative data regarding mountain worker populations (including knowledge, attitudes, and practices [KAPs]; infection status; and serological data), and these data from the testing and control areas were compared to evaluate the effectiveness of BCC strategies in the prevention of malaria. In the BCC malaria prevention strategy testing areas, the accuracy rates of malaria-related KAP were significantly improved among mountain worker populations. The accuracy rates in the 3 aspects of malaria-related KAP increased from 37.73%, 37.00%, and 43.04% to 89.01%, 91.53%, and 92.25%, respectively. The changes in all 3 aspects of KAP were statistically significant (p < 0.01). In the control sites, the changes in the indices were not as marked as in the testing areas, and the change was not statistically significant (p > 0.05). Furthermore, in the testing areas, both the percentage testing positive in the serum malaria indirect fluorescent antibody test (IFAT) and the number of people inflicted decreased more significantly than in the control sites (p < 0.01). The use of the BCC strategy significantly improved the ability of mountain workers in Hainan to avoid malarial infection. Educational and promotional materials and measures were developed and selected in the process, and hands-on experience was gained that will help achieve the goal of total malaria elimination in Hainan.
Wagener, Stefan; Möltner, Andreas; Tımbıl, Sevgi; Gornostayeva, Maryna; Schultz, Jobst-Hendrik; Brüstle, Peter; Mohr, Daniela; Vander Beken, Anna; Better, Julian; Fries, Martin; Gottschalk, Marc; Günther, Janine; Herrmann, Laura; Kreisel, Christian; Moczko, Tobias; Illg, Claudius; Jassowicz, Adam; Müller, Andreas; Niesert, Moritz; Strübing, Felix; Jünger, Jana
2015-01-01
Progress tests provide students feedback on their level of proficiency over the course of their medical studies. Peer-assisted learning and competency-based education have become increasingly important in medical education. Although progress tests have been proven to be useful as a longitudinal feedback instrument, there are currently no progress tests that have been created in cooperation with students or that focus on competency in medical education. In this study, we investigated the extent to which students can be included in the development of a progress test and demonstrated that aspects of knowledge related to competency can be represented on a competency-based progress test. A two-dimensional blueprint for 144 multiple-choice questions (MCQs) covering groups of medical subjects and groups of competency areas was generated by three expert groups for developing the competency-based progress test. A total of 31 students from seven medical schools in Germany actively participated in this exercise. After completing an intensive and comprehensive training programme, the students generated and reviewed the test questions for the competency-based progress test using a separate platform of the ItemManagementSystem (IMS). This test was administered as a formative test to 469 students in a pilot study in November 2013 at eight medical schools in Germany. The scores were analysed for the overall test and differentiated according to the subject groups and competency areas. A pool of more than 200 MCQs was compiled by the students for pilot use, of which 118 student-generated MCQs were used in the progress test. University instructors supplemented this pool with 26 MCQs, which primarily addressed the area of scientific skills. The post-review showed that student-generated MCQs were of high quality with regard to test statistic criteria and content. Overall, the progress test displayed a very high reliability. When the academic years were compared, the progress test mapped out over the course of study not only by the overall test but also in terms of the subject groups and competency areas. Further development in cooperation with students will be continued. Focus will be on compiling additional questions and test formats that can represent competency at a higher skill level, such as key feature questions, situational judgement test questions and OSCE. In addition, the feedback formats will be successively expanded. The intention is also to offer the formative competency-based progress test online.
Access to chlamydia testing in remote and rural Scotland.
Hawkins, Katherine E; Thompson, Lucy; Wilson, Philip
2016-01-01
The aim of this study was to assess access to sexual health care in remote and rural settings using Chlamydia testing as a focus by measuring the extent of Chlamydia testing and positivity across the Scottish Highlands in relation to the Scottish Index of Multiple Deprivation Quintile (SIMD) and Urban Rural 8-fold index (UR8). Tests processed through Raigmore Hospital in Inverness, the main testing laboratory for microbiology tests in North and West and South and Mid Highlands, were studied. Where people are tested in relation to where they live was assessed, as well as the type of test they opt for. Also assessed was the rate of positivity in male and female patients in rural compared with urban settings using the Scottish Government UR8 and in relation to the SIMD. 9644 results were analysed. 77.2% of the results were for females and 22.4% for males. 8.1% of the results were positive and 84.4% were negative. There were proportionately more positive tests from the sexual health sources than from general practice. The proportion of men who had positive tests was almost double that for women (12.7% vs 6.6%) although men made up only 27.9% of the total number of tests. There was no significant difference in positivity when compared with UR8 index or SIMD. 37.7% of people living in the most rural areas (UR8 7-8) had their test performed in a more urban setting (UR8 1-6), and 20.4% people had their test performed in a very urban setting (UR8 1-2). Of these tests, there was a tendency for UR8 7-8 patients to be more likely to have a positive test if tested in an urban setting. These results are similar to previous results in other countries that suggest that Chlamydia positivity is similar in rural and urban settings. A large proportion of people living in more rurally classified areas, and perhaps those with a higher risk, have their test in a central setting, suggesting that they may be bypassing local resources to get a test. The reason for this is not clear. The results also show that men are more likely to have their test in a genitourinary setting as well as have proportionately more positive results. These results support the case for customising sexual health services to the most rural areas and suggest that providing an anonymous testing service in these areas might be beneficial, especially for men.
Seattle wide-area information for travelers (SWIFT) : consumer acceptance study
DOT National Transportation Integrated Search
1998-10-19
The Seattle Wide-area Information for Travelers (SWIFT) 0perational Test was intended to evaluate the performance of a large-scale, urban Advanced Traveler Information System (ATIS) deployment in the Seattle area. With the majority of the SWIFT syste...
DOT National Transportation Integrated Search
1977-06-01
Flight tests were conducted at the National Aviation Facilities Experimental : Center (NAFEC) using a general aviation area navigation (RNAV) system to : investigate system accuracies and resultant airspace requirements in the : terminal area. Issues...
ERIC Educational Resources Information Center
Watkins, James F., Comp.
These written domain referenced tests (DRTs) for the area of transportation/automotive mechanics test cognitive abilities or knowledge of theory. Introductory materials describe domain referenced testing and test development. Each multiple choice test includes a domain statement, describing the behavior and content of the domain, and a test item…
35. VIEW LOOKING NORTHWEST AT THE STATIC TEST TOWER. A ...
35. VIEW LOOKING NORTHWEST AT THE STATIC TEST TOWER. A 'DUMMY' SATURN I BOOSTER IS BEING HOISTED INTO THE TEST STAND TO TEST THE MATING OF THE BOOSTER AND THE TEST STAND. EARLY 1960, PHOTOGRAPHER UNKNOWN, MSFC PHOTO LAB. - Marshall Space Flight Center, Saturn Propulsion & Structural Test Facility, East Test Area, Huntsville, Madison County, AL
Villanueva, Ariadna; Guanche, Humberto
2016-11-01
Aim To describe the effect of education on environmental cleaning in patient care areas using adenosine triphosphate (ATP) readings. Method A quality improvement initiative was developed in a community hospital in Qatar. Over a two-month period, an infection-control practitioner monitored ATP readings in patient care areas, at any time and regardless of the time of the previous disinfection. The initiative included staff education, use of ATP readings and the drawing up of quarterly quality reports. The ATP readings were considered 'pass', meaning well cleaned, or 'fail', meaning non-cleaned, according to the following standards:>250 relative light units (RLU) in non-critical units and<200RLU for critical units. The proportion of test passes was calculated per 100 tests performed. Results A total of 1,617 tests were performed, after which 1,259 (78%) surfaces were identified as well cleaned. The lowest proportion of non-pass and higher ATP readings was observed in non-critical areas. The test points with the lowest proportion of passes were telephones (40.5%), a medication dispensing system (58.5%), an oximeter (66.7%) and callbox buttons (67.6%). A sustained increase in test passes was observed during the study period. Conclusion There was an improvement in environmental cleaning due to monitoring of ATP on surfaces and staff education.
Interaction of high voltage surfaces with the space plasma
NASA Technical Reports Server (NTRS)
Kaufman, H. R.; Robinson, R. S.
1980-01-01
High voltage solar arrays provide spacecraft power while optimizing mass and power efficiency. Operating such arrays in the space plasma environment can result in anomalously large currents being collected through insulation defects. Two thicknesses of the insulating material were tested, with no effect found due to insulator thickness. In these tests the polyimide thickness was always much less than the pinhole diameter. The pinhole area was varied over an area range of more than 30:1. It was found that the current collected was independent of the pinhole area for hole diameters from 0.35 to 2.0 mm. Two types of adhesives were tried in two different configurations. The adhesives were chosen for their extreme difference in vacuum qualifications. Neither adhesive types nor configuration made a significant difference in current collection. The temperature of the insulating material was also varied. It was found that current collection decreased with increasing temperature. Tests were conducted to see if pinhole current collection decreased with time, as was indicated by the effects of several short tests. Current was collected for over four hours while the conductor potential was held constant at 1000 volts. A smooth decrease with time was not observed, but rather a roughly constant current collection with brief surges to high values. Tests were also conducted with the simulated solar cell biased negative. The current was found to be proportional to pinhole area.
UTM Safely Enabling UAS Operations in Low-Altitude Airspace
NASA Technical Reports Server (NTRS)
Kopardekar, Parimal
2017-01-01
Conduct research, development and testing to identify airspace operations requirements to enable large-scale visual and beyond visual line of sight UAS operations in the low-altitude airspace. Use build-a-little-test-a-little strategy remote areas to urban areas Low density: No traffic management required but understanding of airspace constraints. Cooperative traffic management: Understanding of airspace constraints and other operations. Manned and unmanned traffic management: Scalable and heterogeneous operations. UTM construct consistent with FAAs risk-based strategy. UTM research platform is used for simulations and tests. UTM offers path towards scalability.
UTM Safely Enabling UAS Operations in Low-Altitude Airspace
NASA Technical Reports Server (NTRS)
Kopardekar, Parimal H.
2016-01-01
Conduct research, development and testing to identify airspace operations requirements to enable large-scale visual and beyond visual line of sight UAS operations in the low-altitude airspace. Use build-a-little-test-a-little strategy remote areas to urban areas Low density: No traffic management required but understanding of airspace constraints. Cooperative traffic management: Understanding of airspace constraints and other operations. Manned and unmanned traffic management: Scalable and heterogeneous operations. UTM construct consistent with FAAs risk-based strategy. UTM research platform is used for simulations and tests. UTM offers path towards scalability.
NASA Technical Reports Server (NTRS)
Kamman, J. H.; Hall, C. L.
1975-01-01
Two inlet performance tests and one inlet/airframe drag test were conducted in 1969 at the NASA-Ames Research Center. The basic inlet system was two-dimensional, three ramp (overhead), external compression, with variable capture area. The data from these tests were analyzed to show the effects of selected design variables on the performance of this type of inlet system. The inlet design variables investigated include inlet bleed, bypass, operating mass flow ratio, inlet geometry, and variable capture area.
Considerations in STS payload environmental verification
NASA Technical Reports Server (NTRS)
Keegan, W. B.
1978-01-01
The current philosophy of the GSFS regarding environmental verification of Shuttle payloads is reviewed. In the structures area, increased emphasis will be placed on the use of analysis for design verification, with selective testing performed as necessary. Furthermore, as a result of recent cost optimization analysis, the multitier test program will presumably give way to a comprehensive test program at the major payload subassembly level after adequate workmanship at the component level has been verified. In the thermal vacuum area, thought is being given to modifying the approaches used for conventional spacecraft.
Carter, J.M.
1999-01-01
This report presents selected data on wells and test holes that were used in the construction of structure-contour maps of selected formations that contain major aquifers in the Black Hills area of western South Dakota. Altitudes of the top of the Inyan Kara Group, Minnekahta Limestone, Minnelusa Formation, Madison Limestone, and Deadwood Formation are presented for the wells and test holes presented in this report.
22. DETAIL, TWO LIGHTING TYPES AT REAR OF TEST STAND ...
22. DETAIL, TWO LIGHTING TYPES AT REAR OF TEST STAND 1-A. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA
The SLS Stages Intertank Structural Test Assembly (STA) arrives at MSFC
2018-03-08
The SLS Stages Intertank Structural Test Assembly (STA) is rolling off the NASA Pegasus Barge at the MSFC Dock enroute to the MSFC 4619 Load Test Annex test facility for qualification testing via MSFC West Test Area. Historic Saturn 1-C test stand on far left, blockhouse 4670 on far right, SLS LH2 test stand, 4693, in center.
Gen 2.0 Mixer/Ejector Nozzle Test at LSAF June 1995 to July 1996
NASA Technical Reports Server (NTRS)
Arney, L. D.; Sandquist, D. L.; Forsyth, D. W.; Lidstone, G. L.; Long-Davis, Mary Jo (Technical Monitor)
2005-01-01
Testing of the HSCT Generation 2.0 nozzle model hardware was conducted at the Boeing Low Speed Aeroacoustic Facility, LSAF. Concurrent measurements of noise and thrust were made at critical takeoff design conditions for a variety of mixer/ejector model hardware. Design variables such as suppressor area ratio, mixer area ratio, liner type and thickness, ejector length, lobe penetration, and mixer chute shape were tested. Parallel testing was conducted at G.E.'s Cell 41 acoustic free jet facility to augment the LSAF test. The results from the Gen 2.0 testing are being used to help shape the current nozzle baseline configuration and guide the efforts in the upcoming Generation 2.5 and 3.0 nozzle tests. The Gen 2.0 results have been included in the total airplane system studies conducted at MDC and Boeing to provide updated noise and thrust performance estimates.
Design and Fabrication of a Tank-Applied Broad Area Cooling Shield Coupon
NASA Technical Reports Server (NTRS)
Wood, J. J.; Middlemas, M. R.
2012-01-01
The small-scale broad area cooling (BAC) shield test panel represents a section of the cryogenic propellant storage and transfer ground test article, a flight-like cryogenic propellant storage tank. The test panel design includes an aluminum tank shell, primer, spray-on foam insulation, multilayer insulation (MLI), and BAC shield hardware. This assembly was sized to accurately represent the character of the MLI/BAC shield system, be quickly and inexpensively assembled, and be tested in the Marshall Space Flight Center Acoustic Test Facility. Investigating the BAC shield response to a worst-case launch dynamic load was the key purpose for developing the test article and performing the test. A preliminary method for structurally supporting the BAC shield using low-conductivity standoffs was designed, manufactured, and evaluated as part of the test. The BAC tube-standoff interface and unsupported BAC tube lengths were key parameters for evaluation. No noticeable damage to any system hardware element was observed after acoustic testing.
1976-01-06
At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was originally designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage. Modifications to the S-IC Test Stand began in 1975 to accommodate space shuttle external tank testing. This photo is of the horizontal liquid oxygen tanks.
Senior, Lisa A.; Conger, Randall W.; Bird, Philip H.
2008-01-01
Ground water in the vicinity of several industrial facilities in Upper Gwynedd Township and Lansdale Borough, Montgomery County, Pa., is contaminated with several volatile organic compounds (VOCs). The 2-square-mile area was placed on the National Priorities List as the North Penn Area 7 Superfund Site by the U.S. Environmental Protection Agency (USEPA) in 1989. The U.S. Geological Survey (USGS) conducted geophysical logging, aquifer testing, water-level monitoring, and streamflow measurements in the vicinity of North Penn Area 7 from October 2002 through December 2006. This followed work that began in 2000 to assist the USEPA in developing an understanding of the hydrogeologic framework in the area as part of the USEPA Remedial Investigation. The study area is underlain by Triassic- and Jurassic-age sandstones, siltstones, and shales of the Lockatong Formation and the Brunswick Group. Regionally, these rocks strike northeast and dip to the northwest. The sequence of rocks form fractured-rock aquifers that act as a set of confined to semi-confined layered aquifers of differing permeabilities. The aquifers are recharged by precipitation and discharge to streams and wells. The Wissahickon Creek headwaters are less than 1 mile northeast of the study area. This stream flows southwest approximately parallel to strike and bisects North Penn Area 7. Ground water is pumped in the vicinity of North Penn Area 7 for industrial use and public supply. The USGS collected geophysical logs for 42 wells that ranged in depth from 40 to 477 ft. Aquifer-interval-isolation testing was done in 17 of the 42 wells, for a total of 122 zones tested. A multiple-well aquifer test was conducted by monitoring the response of 14 wells to pumping and shutdown of a 600-ft deep production well in November-December 2004. In addition, water levels were monitored continuously in four wells in the area from October 2002 through September 2006, and streamflow was measured quarterly at two sites on Wissahickon Creek from December 2002 through September 2005. Geophysical logging identified water-bearing zones associated with high-angle fractures and bedding-plane openings throughout the depth of the boreholes. Heatpulse-flowmeter measurements under non-pumping, ambient conditions in 16 wells greater than 200 ft in depth indicated that borehole flow, where detected, was only upward in 2 wells and only downward in 5 wells. In nine wells, both upward and downward flow were measured. Geologic structure and pumping in the area affect the spatial distribution of vertical gradients. Heatpulse-flowmeter measurements under pumping conditions were used to identify the most productive intervals in wells. Correlation of natural-gamma-ray logs indicated bedding in the area probably strikes about 45 to 65 degrees northeast and dips about 9 degrees northwest. Aquifer intervals isolated by inflatable packers in 17 wells were pumped to test productivity of water-bearing zones and to collect samples to determine chemical quality of water produced from the interval. Interval-isolation testing confirmed the vertical hydraulic gradients indicated by heatpulse-flowmeter measurements. The specific capacities of the 122 isolated intervals ranged over about three orders of magnitude, from 0.01 to 10.6 gallons per minute per foot, corresponding to calculated transmissivities of 1.2 to 2,290 feet squared per day. Intervals adjacent to isolated pumped intervals commonly showed little response to pumping of the isolated zone. The presence of vertical hydraulic gradients and lack of adjacent-interval response to pumping in isolated intervals indicate a limited degree of vertical hydraulic connection between the aquifer sections tested. Differences were apparent in inorganic water quality of water from isolated intervals, including pH, specific conductance, and dissolved oxygen. Concentrations of most VOC contaminants in most wells with predominantly upward vertical gradients were g
Results of the second phase of the drought-disaster test-drilling program near Morristown, N.J.
Vecchioli, John; Nichols, William D.; Nemickas, Bronius
1967-01-01
The continued drought in northeastern New Jersey through the summer of 1966 with its attendant water-supply problems resulted in an extension of the drought-disaster test-drilling program originally requested by the Office of Emergency Planning on August 30, 1965. Authorization to continue test drilling was fiven by the Office of Emergency Planning on September 26, 1966, with the stipulation that all field work be complete by January 31, 1977. Contractural costs were paid by the Office of Emergency Planning, whereas personnel costs were shared by the U.S. Geological Survey and the New Jersey Department of Conservation and Economic Development, Division of Water Policy and Supply.The work undertaken in 1965 by the Geological Survey was "...to preform the necessary drilling and testing of wells to identify the extent and nature of a reserve ground-water source in the vicinity of the Passaic River near the northern New Jersey metropolitan area." Results of this first phase were made available in the fall of 1966 in Water Resources Circular 16 of the New Jersey Department of Conservation and Economic Development. Three of the five areas tested (figure 1)--two in Parsippany-Troy Hills Township (areas 2 and 4) and one in East Hanover Township (area 1), Morris County--proved capable of providing an aggregate sustained yield of 7.5 million gallons daily (mgd) from wells constructed in sand and gravel deposits. Because significant supplies of ground water for emergency use were located in the first phase of the exploratory test-drilling program, it was though desirable to extend the originally planned studies so as to obtain maximum practicable information on emergency supplies.During this second phase of the investigation, drilling was conducted in 16 sites in Chatham, Madison, and Florham Park Boroughs and in Hanover and East Hanover Townships, Morris County. (See figure 2.) The drilling in Hanover and East Hanover Townships, and part of the drilling done in Florham Park was to explore the availability of large undeveloped ground-water supplies. Drilling in Chatham, Madison, and Florham Park Boroughs was done primarily to determine the extent and continuity of buried valley-fill aquifers, so that a full evaluation of the effects of pumpage from other areas on these already heavily pumped areas could be made. In addition, it was anticipated that the drilling could help in defining the feasibility of artificial recharge of the heavily pumped areas and in the determination of the prospective method of recharge and points of emplacement.Arrangements for easements with landowners, preparation of specifications for well drilling and seismic work, and supervision of well drilling and seismic contracts were all performed by the New Jersey District, Water Resources Division of the Geological Survey.Prior to the test drilling, seismic exploration under contract with Alpine Geophysical Associates of Norwood, N. J. was conducted at five locations in the Chatham-Madison-Florham Park area and at one place in Parsippany-Troy Hills Township. The seismic work was done to determine the most favorable location for a test well at several potential test-well sites and to help in the interpretation of subsurface geology between test sites.Contracts for the drilling of the test holes were awarded during November and drilling commences on November 30. Kaye Well drilling, Inc. of Jackson, N. J. was the recipient of a contract for eight of the test holes, and a second contract was awarded to Rinbrand Well Drilling Co., Inc. of Glen Rock, N. J.--also for eight test holes.Acknowledgment is due to the many public officials of Chatham, Madison, Florham Park, Morristown, and East Hanover Township as well as officials of the Braidburn Corporation and Esso Research and Engineering Co., who cooperated by making their lands available for exploration.
Rubio, Jorge; Zarzosa, José Ignacio; Pallarés, Antonio
2017-09-01
The aim of this study was to compare the cutting are, root canal anatomy preservation and non-instrumented areas of F360®, F6-SkyTaper®, Hyflex-EDM®, iRACE®, Neoniti®, O.Shape®, P.Next®, Reciproc®, Revo-S® and Wave-One-Gold® size 25 files. 300 teeth with a single straight root and a circular or elliptical root canal were divided into 10 groups (1-F360®, 2- F6-SkyTaper®, 3-Hyflex-EDM®, 4-iRACE®, 5-Neoniti®, 6-O.Shape®, 7-P.Next®, 8-Reciproc®, 9-Revo-S® and 10-Wave-One-Gold®) cut into 3 cross sections using an ultrafine cutting disc. They were photographed under a stereo microscope and preinstrumentation analyses were made before rebuilding the teeth with# 10 K- File and epoxy glue. A glide path was created with #10 and #15 K files and each group was instrumented using rotary or reciprocating systems. Cutting areas, root canal anatomy preservation and non-instrumented areas were analyzed using the AutoCAD 2015 Levene's test, the Welch´s test, and the Games-Howell´s test. The Pearson's chi-squared test was used for statistical analysis. Levene's test showed no equality of variances (P<0.05), therefore Welch´s and Games-Howell's tests were applied to cutting areas, showing significant differences in all thirds and overall (P<0.05). No differences in root canal anatomy preservation were observed (P>0.05). In non-instrumented areas, significant differences were found (P<0.05) in middle third being better in Reciproc®, Neoniti® and WaveOneGold®, and in apical thirds being higher P.Next®, Reciproc®, HyflexEDM®, Neoniti® and WaveOneGold®. In cutting area, P.Next® and Reciproc® were superior in coronal third, Neoniti® and Hyflex EDM® medially and apically and Neoniti® and Reciproc® overall. Regarding the root canal anatomy preservation, all systems were similar. For non-instrumented areas, all systems achieved similar results coronally, but Reciproc®, Neoniti® and Wave One Gold® were superior in middle third and P.Next®, Reciproc®, Hyflex EDM®, Neoniti® and Wave One Gold® were superior in apically.
Comparison of Shaping Ability of 10 Rotary and Reciprocating Systems: an In Vitro Study with AutoCad
Zarzosa, José Ignacio; Pallarés, Antonio
2017-01-01
Objective The aim of this study was to compare the cutting are, root canal anatomy preservation and non-instrumented areas of F360®, F6-SkyTaper®, Hyflex-EDM®, iRACE®, Neoniti®, O.Shape®, P.Next®, Reciproc®, Revo-S® and Wave-One-Gold® size 25 files. Materials and Methods 300 teeth with a single straight root and a circular or elliptical root canal were divided into 10 groups (1-F360®, 2- F6-SkyTaper®, 3-Hyflex-EDM®, 4-iRACE®, 5-Neoniti®, 6-O.Shape®, 7-P.Next®, 8-Reciproc®, 9-Revo-S® and 10-Wave-One-Gold®) cut into 3 cross sections using an ultrafine cutting disc. They were photographed under a stereo microscope and preinstrumentation analyses were made before rebuilding the teeth with# 10 K- File and epoxy glue. A glide path was created with #10 and #15 K files and each group was instrumented using rotary or reciprocating systems. Cutting areas, root canal anatomy preservation and non-instrumented areas were analyzed using the AutoCAD 2015 Levene's test, the Welch´s test, and the Games-Howell´s test. The Pearson’s chi-squared test was used for statistical analysis. Results Levene's test showed no equality of variances (P<0.05), therefore Welch´s and Games-Howell's tests were applied to cutting areas, showing significant differences in all thirds and overall (P<0.05). No differences in root canal anatomy preservation were observed (P>0.05). In non-instrumented areas, significant differences were found (P<0.05) in middle third being better in Reciproc®, Neoniti® and WaveOneGold®, and in apical thirds being higher P.Next®, Reciproc®, HyflexEDM®, Neoniti® and WaveOneGold®. Conclusions In cutting area, P.Next® and Reciproc® were superior in coronal third, Neoniti® and Hyflex EDM® medially and apically and Neoniti® and Reciproc® overall. Regarding the root canal anatomy preservation, all systems were similar. For non-instrumented areas, all systems achieved similar results coronally, but Reciproc®, Neoniti® and Wave One Gold® were superior in middle third and P.Next®, Reciproc®, Hyflex EDM®, Neoniti® and Wave One Gold® were superior in apically. PMID:29225361
Objective sensory evaluation of the spread of complex regional pain syndrome.
Edinger, Lara; Schwartzman, Robert J; Ahmad, Ayesha; Erwin, Kirsten; Alexander, Guillermo M
2013-01-01
The spread of complex regional pain syndrome (CRPS) has been well documented. Many severe refractory long-standing patients have total body pain (TBP) that evolved from a single extremity injury. The purpose of this study was to document by objective sensory threshold testing the extent of body area involvement in 20 long-standing patients with CRPS who have TBP. A comparison of sensory threshold testing parameters between 20 long-standing refractory patients with CRPS who have TBP versus 10 healthy participants. Twenty patients with CRPS who stated that they suffered from total body pain were chosen from the Drexel University College of Medicine CRPS database. They were compared to 10 healthy participants that were age and gender matched to the patients with CRPS. The sensory parameters tested were: skin temperature; static and mechanical allodynia; thermal allodynia; mechanical hyperalgesia; after sensations following all sensory tests. The sites chosen for testing in the patients with CRPS were the most painful area in each of 8 body regions that comprised the total body area. Five patients with CRPS had signs of CRPS over 100% of their body (20%). One patient had pain over 87% and another had pain over 90% of their body area. The average percentage of body involvement was 62% (range 37% - 100%). All patients with CRPS had at least one sensory parameter abnormality in all body regions. All patients with CRPS had lower pain thresholds for static allodynia in all body areas, while 50% demonstrated a lower threshold for dynamic allodynia in all body regions compared to the healthy participants. Cold allodynia had a higher median pain rating on the Likert pain scale in all body areas versus healthy participants except for the chest, abdomen, and back. Eighty-five percent of the patients with CRPS had a significantly lower pain threshold for mechanical hyperalgesia in all body areas compared to the healthy participants. After sensations occurred after all sensory parameters in the extremities in patients with CRPS. The primary limitations of this study would be the variability of self-reported data (each subject's assessment of pain/ discomfort to a tested parameter) and the challenge to uniformly administer each parameter's assessment since simple tools and not precision instruments were used (with the exception of skin temperature). TBP and objective sensory loss occur in 20% of patients with refractory long-standing CRPS.
Outdoor Testing Areas | Energy Systems Integration Facility | NREL
of engineers running tests on plug-in hybrid electric vehicles at the Medium-Voltage Outdoor Test large microgrids hub, located in the outdoor low-voltage test yard, includes underground trench access pits for full enclosure of rotating machinery under test. Key Infrastructure Secured underground pits
40 CFR 53.30 - General provisions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... more information about the site. Any such pre-test approval of a test site by the EPA shall indicate... Methods and Reference Methods § 53.30 General provisions. (a) Determination of comparability. The test... discretion of the Administrator. (b) Selection of test sites. (1) Each test site shall be in an area which...
40 CFR 53.30 - General provisions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... more information about the site. Any such pre-test approval of a test site by the EPA shall indicate... Methods and Reference Methods § 53.30 General provisions. (a) Determination of comparability. The test... discretion of the Administrator. (b) Selection of test sites. (1) Each test site shall be in an area which...
40 CFR 53.30 - General provisions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... more information about the site. Any such pre-test approval of a test site by the EPA shall indicate... Methods and Reference Methods § 53.30 General provisions. (a) Determination of comparability. The test... discretion of the Administrator. (b) Selection of test sites. (1) Each test site shall be in an area which...
40 CFR 53.30 - General provisions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... more information about the site. Any such pre-test approval of a test site by the EPA shall indicate... Methods and Reference Methods § 53.30 General provisions. (a) Determination of comparability. The test... discretion of the Administrator. (b) Selection of test sites. (1) Each test site shall be in an area which...
40 CFR 53.30 - General provisions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... more information about the site. Any such pre-test approval of a test site by the EPA shall indicate... Methods and Reference Methods § 53.30 General provisions. (a) Determination of comparability. The test... discretion of the Administrator. (b) Selection of test sites. (1) Each test site shall be in an area which...
Young, Alvin L; Newton, Michael
2004-01-01
From 1961-1971, The Air Development Test Center, Eglin Air Force Base (AFB), Florida, developed, tested, and calibrated the aerial spray systems used in support of Operation RANCH HAND and the US Army Chemical Corps in Vietnam. Twenty major test and evaluation projects of aerial spray equipment were conducted on four fully instrumented test grids, each uniquely arrayed to match the needs of fixed-wing, helicopter, or jet aircraft. Each of the grids was established within the boundary of Test Area 52A of the Eglin Reservation. The tests, conducted under climatic and environmental conditions similar to those in Vietnam, included the use of the military herbicides (Agents) Orange, Purple, White, and Blue. Approximately 75,000 kg of 2,4,5-trichlorophenoxyacetic acid (2,4,5-T) and 76,000 kg of 2,4-dichlorophenoxyacetic acid (2,4-D) were aerially disseminated on an area of less than 3 km2 during the period 1962-1970. Data from the analysis of archived samples suggested that an estimated 3.1 kg of 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD), present as a contaminant, were aerially released in the test area. Because most of the vegetation had been removed before establishing the test site in 1961, there was an opportunity to follow ground-based residues independent of canopy interception, and the resulting high solar exposure of initial residues. Studies of the soils, fauna, flora, and aquatic ecosystems of the test grids and associated perimeters of Test Area C-52A (an area totally more than 8 km2) were initiated in 1969 and concluded in 1984. Data from soil samples collected from 1974 through 1984 suggested that less than one percent of the TCDD that was present in soil when sampling began persisted through the ten-year period of sampling. More than 340 species of organisms were observed and identified within the test area. More than 300 biological samples were analyzed for TCDD and detectable residues were found in 16 of 45 species examined. Examination of the ecological niches of the species containing TCDD residues suggested each was in close contact with contaminated soil. Indepth field studies, including anatomical, histological and ultrastructural examinations, spanning more than 50 generations of the Beachmouse, Peromyscus polionotus, demonstrated that continual exposure to soil concentrations of 0.1 to 1.5 parts-per-billion (ng/g) of TCDD, had minimal effects upon the health and reproduction of this species. Since Agent Orange with its associated TCDD contaminant was aerially disseminated on the test grids, Test Area C-52A provided a 'field laboratory' for what may have happened in Vietnam, had there been no intercepting forest cover. However, in Vietnam a 'typical' mission would have disseminated 14.8 kg of 2,4,5-T/ha, most of which was intercepted by the forest canopy, versus the 876 kg 2,4,5-T/ha on the test grid at Eglin. Moreover, each hectare on the Eglin test grid received at least 1,300 times more TCDD than a hectare sprayed with Agent Orange in Vietnam. The disappearance or persistence of TCDD is dependent upon how it enters the ecosystem. Spray equipment test and evaluations missions at Eglin were generally scheduled and conducted with environmental conditions that were optimal for spray operations. This suggests that conditions favorable for dissemination of herbicide were the same conditions favorable for photodegradation of TCDD. It was likely that 99 percent of the TCDD never persisted beyond the day of application. No long-term adverse ecological effects were documented in these studies despite the massive quantities of herbicides and TCDD that were applied to the site. Reviews by the US Environmental Protection Agency and the National Academy of Sciences' Institute of Medicine did not address the fate of Agent Orange and TCDD as described in these studies from Eglin AFB, Florida.