Sample records for multi-parameter heart rate

  1. Quantitative Assessment of Heart Rate Dynamics during Meditation: An ECG Based Study with Multi-Fractality and Visibility Graph

    PubMed Central

    Bhaduri, Anirban; Ghosh, Dipak

    2016-01-01

    The cardiac dynamics during meditation is explored quantitatively with two chaos-based non-linear techniques viz. multi-fractal detrended fluctuation analysis and visibility network analysis techniques. The data used are the instantaneous heart rate (in beats/minute) of subjects performing Kundalini Yoga and Chi meditation from PhysioNet. The results show consistent differences between the quantitative parameters obtained by both the analysis techniques. This indicates an interesting phenomenon of change in the complexity of the cardiac dynamics during meditation supported with quantitative parameters. The results also produce a preliminary evidence that these techniques can be used as a measure of physiological impact on subjects performing meditation. PMID:26909045

  2. Quantitative Assessment of Heart Rate Dynamics during Meditation: An ECG Based Study with Multi-Fractality and Visibility Graph.

    PubMed

    Bhaduri, Anirban; Ghosh, Dipak

    2016-01-01

    The cardiac dynamics during meditation is explored quantitatively with two chaos-based non-linear techniques viz. multi-fractal detrended fluctuation analysis and visibility network analysis techniques. The data used are the instantaneous heart rate (in beats/minute) of subjects performing Kundalini Yoga and Chi meditation from PhysioNet. The results show consistent differences between the quantitative parameters obtained by both the analysis techniques. This indicates an interesting phenomenon of change in the complexity of the cardiac dynamics during meditation supported with quantitative parameters. The results also produce a preliminary evidence that these techniques can be used as a measure of physiological impact on subjects performing meditation.

  3. Noncontact measurement of heart rate using facial video illuminated under natural light and signal weighted analysis.

    PubMed

    Yan, Yonggang; Ma, Xiang; Yao, Lifeng; Ouyang, Jianfei

    2015-01-01

    Non-contact and remote measurements of vital physical signals are important for reliable and comfortable physiological self-assessment. We presented a novel optical imaging-based method to measure the vital physical signals. Using a digital camera and ambient light, the cardiovascular pulse waves were extracted better from human color facial videos correctly. And the vital physiological parameters like heart rate were measured using a proposed signal-weighted analysis method. The measured HRs consistent with those measured simultaneously with reference technologies (r=0.94, p<0.001 for HR). The results show that the imaging-based method is suitable for measuring the physiological parameters, and provide a reliable and comfortable measurement mode. The study lays a physical foundation for measuring multi-physiological parameters of human noninvasively.

  4. Simultaneous measurement and modulation of multiple physiological parameters in the isolated heart using optical techniques

    PubMed Central

    Lee, Peter; Yan, Ping; Ewart, Paul; Kohl, Peter

    2012-01-01

    Whole-heart multi-parametric optical mapping has provided valuable insight into the interplay of electro-physiological parameters, and this technology will continue to thrive as dyes are improved and technical solutions for imaging become simpler and cheaper. Here, we show the advantage of using improved 2nd-generation voltage dyes, provide a simple solution to panoramic multi-parametric mapping, and illustrate the application of flash photolysis of caged compounds for studies in the whole heart. For proof of principle, we used the isolated rat whole-heart model. After characterising the blue and green isosbestic points of di-4-ANBDQBS and di-4-ANBDQPQ, respectively, two voltage and calcium mapping systems are described. With two newly custom-made multi-band optical filters, (1) di-4-ANBDQBS and fluo-4 and (2) di-4-ANBDQPQ and rhod-2 mapping are demonstrated. Furthermore, we demonstrate three-parameter mapping using di-4-ANBDQPQ, rhod-2 and NADH. Using off-the-shelf optics and the di-4-ANBDQPQ and rhod-2 combination, we demonstrate panoramic multi-parametric mapping, affording a 360° spatiotemporal record of activity. Finally, local optical perturbation of calcium dynamics in the whole heart is demonstrated using the caged compound, o-nitrophenyl ethylene glycol tetraacetic acid (NP-EGTA), with an ultraviolet light-emitting diode (LED). Calcium maps (heart loaded with di-4-ANBDQPQ and rhod-2) demonstrate successful NP-EGTA loading and local flash photolysis. All imaging systems were built using only a single camera. In conclusion, using novel 2nd-generation voltage dyes, we developed scalable techniques for multi-parametric optical mapping of the whole heart from one point of view and panoramically. In addition to these parameter imaging approaches, we show that it is possible to use caged compounds and ultraviolet LEDs to locally perturb electrophysiological parameters in the whole heart. PMID:22886365

  5. Support-vector-machines-based multidimensional signal classification for fetal activity characterization

    NASA Astrophysics Data System (ADS)

    Ribes, S.; Voicu, I.; Girault, J. M.; Fournier, M.; Perrotin, F.; Tranquart, F.; Kouamé, D.

    2011-03-01

    Electronic fetal monitoring may be required during the whole pregnancy to closely monitor specific fetal and maternal disorders. Currently used methods suffer from many limitations and are not sufficient to evaluate fetal asphyxia. Fetal activity parameters such as movements, heart rate and associated parameters are essential indicators of the fetus well being, and no current device gives a simultaneous and sufficient estimation of all these parameters to evaluate the fetus well-being. We built for this purpose, a multi-transducer-multi-gate Doppler system and developed dedicated signal processing techniques for fetal activity parameter extraction in order to investigate fetus's asphyxia or well-being through fetal activity parameters. To reach this goal, this paper shows preliminary feasibility of separating normal and compromised fetuses using our system. To do so, data set consisting of two groups of fetal signals (normal and compromised) has been established and provided by physicians. From estimated parameters an instantaneous Manning-like score, referred to as ultrasonic score was introduced and was used together with movements, heart rate and associated parameters in a classification process using Support Vector Machines (SVM) method. The influence of the fetal activity parameters and the performance of the SVM were evaluated using the computation of sensibility, specificity, percentage of support vectors and total classification accuracy. We showed our ability to separate the data into two sets : normal fetuses and compromised fetuses and obtained an excellent matching with the clinical classification performed by physician.

  6. Classifying syndromes in Chinese medicine using multi-label learning algorithm with relevant features for each label.

    PubMed

    Xu, Jin; Xu, Zhao-Xia; Lu, Ping; Guo, Rui; Yan, Hai-Xia; Xu, Wen-Jie; Wang, Yi-Qin; Xia, Chun-Ming

    2016-11-01

    To develop an effective Chinese Medicine (CM) diagnostic model of coronary heart disease (CHD) and to confifirm the scientifific validity of CM theoretical basis from an algorithmic viewpoint. Four types of objective diagnostic data were collected from 835 CHD patients by using a self-developed CM inquiry scale for the diagnosis of heart problems, a tongue diagnosis instrument, a ZBOX-I pulse digital collection instrument, and the sound of an attending acquisition system. These diagnostic data was analyzed and a CM diagnostic model was established using a multi-label learning algorithm (REAL). REAL was employed to establish a Xin (Heart) qi defificiency, Xin yang defificiency, Xin yin defificiency, blood stasis, and phlegm fifive-card CM diagnostic model, which had recognition rates of 80.32%, 89.77%, 84.93%, 85.37%, and 69.90%, respectively. The multi-label learning method established using four diagnostic models based on mutual information feature selection yielded good recognition results. The characteristic model parameters were selected by maximizing the mutual information for each card type. The four diagnostic methods used to obtain information in CM, i.e., observation, auscultation and olfaction, inquiry, and pulse diagnosis, can be characterized by these parameters, which is consistent with CM theory.

  7. A Pulse Rate Detection Method for Mouse Application Based on Multi-PPG Sensors

    PubMed Central

    Chen, Wei-Hao

    2017-01-01

    Heart rate is an important physiological parameter for healthcare. Among measurement methods, photoplethysmography (PPG) is an easy and convenient method for pulse rate detection. However, as the PPG signal faces the challenge of motion artifacts and is constrained by the position chosen, the purpose of this paper is to implement a comfortable and easy-to-use multi-PPG sensor module combined with a stable and accurate real-time pulse rate detection method on a computer mouse. A weighted average method for multi-PPG sensors is used to adjust the weight of each signal channel in order to raise the accuracy and stability of the detected signal, therefore reducing the disturbance of noise under the environment of moving effectively and efficiently. According to the experiment results, the proposed method can increase the usability and probability of PPG signal detection on palms. PMID:28708112

  8. Resting Heart Rate as Predictor for Left Ventricular Dysfunction and Heart Failure: The Multi-Ethnic Study of Atherosclerosis

    PubMed Central

    Opdahl, Anders; Venkatesh, Bharath Ambale; Fernandes, Veronica R. S.; Wu, Colin O.; Nasir, Khurram; Choi, Eui-Young; Almeida, Andre L. C.; Rosen, Boaz; Carvalho, Benilton; Edvardsen, Thor; Bluemke, David A.; Lima, Joao A. C.

    2014-01-01

    OBJECTIVE To investigate the relationship between baseline resting heart rate and incidence of heart failure (HF) and global and regional left ventricular (LV) dysfunction. BACKGROUND The association of resting heart rate to HF and LV function is not well described in an asymptomatic multi-ethnic population. METHODS Participants in the Multi-Ethnic Study of Atherosclerosis had resting heart rate measured at inclusion. Incident HF was registered (n=176) during follow-up (median 7 years) in those who underwent cardiac MRI (n=5000). Changes in ejection fraction (ΔEF) and peak circumferential strain (Δεcc) were measured as markers of developing global and regional LV dysfunction in 1056 participants imaged at baseline and 5 years later. Time to HF (Cox model) and Δεcc and ΔEF (multiple linear regression models) were adjusted for demographics, traditional cardiovascular risk factors, calcium score, LV end-diastolic volume and mass in addition to resting heart rate. RESULTS Cox analysis demonstrated that for 1 bpm increase in resting heart rate there was a 4% greater adjusted relative risk for incident HF (Hazard Ratio: 1.04 (1.02, 1.06 (95% CI); P<0.001). Adjusted multiple regression models demonstrated that resting heart rate was positively associated with deteriorating εcc and decrease in EF, even in analyses when all coronary heart disease events were excluded from the model. CONCLUSION Elevated resting heart rate is associated with increased risk for incident HF in asymptomatic participants in MESA. Higher heart rate is related to development of regional and global LV dysfunction independent of subclinical atherosclerosis and coronary heart disease. PMID:24412444

  9. Short-term association between personal exposure to noise and heart rate variability: The RECORD MultiSensor Study.

    PubMed

    El Aarbaoui, Tarik; Méline, Julie; Brondeel, Ruben; Chaix, Basile

    2017-12-01

    Studies revealed long-term associations between noise exposure and cardiovascular health, but the underlying short-term mechanisms remain uncertain. To explore the concomitant and lagged short-term associations between personal exposure to noise and heart rate variability (HRV) in a real life setting in the Île-de-France region. The RECORD MultiSensor Study collected between July 2014 and June 2015 noise and heart rate data for 75 participants, aged 34-74 years, in their living environments for 7 days using a personal dosimeter and electrocardiography (ECG) sensor on the chest. HRV parameters and noise levels were calculated for 5-min windows. Short-term relationships between noise level and log-transformed HRV parameters were assessed using mixed effects models with a random intercept for participants and a temporal autocorrelation structure, adjusted for heart rate, physical activity (accelerometry), and short-term trends. An increase by one dB(A) of A-weighted equivalent sound pressure level (Leq) was associated with a 0.97% concomitant increase of the Standard deviation of normal to normal intervals (SDNN) (95% CI: 0.92, 1.02), of 2.08% of the Low frequency band power (LF) (95% CI: 1.97, 2.18), of 1.30% of the High frequency band power (HF) (95% CI: 1.17, 1.43), and of 1.16% of the LF/HF ratio (95% CI: 1.10, 1.23). The analysis of lagged exposures to noise adjusted for the concomitant exposure illustrates the dynamic of recovery of the autonomic nervous system. Non-linear associations were documented with all HRV parameters with the exception of HF. Piecewise regression revealed that the association was almost 6 times stronger below than above 65 Leq dB(A) for the SDNN and LF/HF ratio. Personal noise exposure was found to be related to a concomitant increase of the overall HRV, with evidence of imbalance of the autonomic nervous system towards sympathetic activity, a pathway to increased cardiovascular morbidity and mortality. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Towards Personalized Cardiology: Multi-Scale Modeling of the Failing Heart

    PubMed Central

    Amr, Ali; Neumann, Dominik; Georgescu, Bogdan; Seegerer, Philipp; Kamen, Ali; Haas, Jan; Frese, Karen S.; Irawati, Maria; Wirsz, Emil; King, Vanessa; Buss, Sebastian; Mereles, Derliz; Zitron, Edgar; Keller, Andreas; Katus, Hugo A.; Comaniciu, Dorin; Meder, Benjamin

    2015-01-01

    Background Despite modern pharmacotherapy and advanced implantable cardiac devices, overall prognosis and quality of life of HF patients remain poor. This is in part due to insufficient patient stratification and lack of individualized therapy planning, resulting in less effective treatments and a significant number of non-responders. Methods and Results State-of-the-art clinical phenotyping was acquired, including magnetic resonance imaging (MRI) and biomarker assessment. An individualized, multi-scale model of heart function covering cardiac anatomy, electrophysiology, biomechanics and hemodynamics was estimated using a robust framework. The model was computed on n=46 HF patients, showing for the first time that advanced multi-scale models can be fitted consistently on large cohorts. Novel multi-scale parameters derived from the model of all cases were analyzed and compared against clinical parameters, cardiac imaging, lab tests and survival scores to evaluate the explicative power of the model and its potential for better patient stratification. Model validation was pursued by comparing clinical parameters that were not used in the fitting process against model parameters. Conclusion This paper illustrates how advanced multi-scale models can complement cardiovascular imaging and how they could be applied in patient care. Based on obtained results, it becomes conceivable that, after thorough validation, such heart failure models could be applied for patient management and therapy planning in the future, as we illustrate in one patient of our cohort who received CRT-D implantation. PMID:26230546

  11. Measurement and Data Transmission Validity of a Multi-Biosensor System for Real-Time Remote Exercise Monitoring Among Cardiac Patients.

    PubMed

    Rawstorn, Jonathan C; Gant, Nicholas; Warren, Ian; Doughty, Robert Neil; Lever, Nigel; Poppe, Katrina K; Maddison, Ralph

    2015-03-20

    Remote telemonitoring holds great potential to augment management of patients with coronary heart disease (CHD) and atrial fibrillation (AF) by enabling regular physiological monitoring during physical activity. Remote physiological monitoring may improve home and community exercise-based cardiac rehabilitation (exCR) programs and could improve assessment of the impact and management of pharmacological interventions for heart rate control in individuals with AF. Our aim was to evaluate the measurement validity and data transmission reliability of a remote telemonitoring system comprising a wireless multi-parameter physiological sensor, custom mobile app, and middleware platform, among individuals in sinus rhythm and AF. Participants in sinus rhythm and with AF undertook simulated daily activities, low, moderate, and/or high intensity exercise. Remote monitoring system heart rate and respiratory rate were compared to reference measures (12-lead ECG and indirect calorimeter). Wireless data transmission loss was calculated between the sensor, mobile app, and remote Internet server. Median heart rate (-0.30 to 1.10 b∙min -1 ) and respiratory rate (-1.25 to 0.39 br∙min -1 ) measurement biases were small, yet statistically significant (all P≤.003) due to the large number of observations. Measurement reliability was generally excellent (rho=.87-.97, all P<.001; intraclass correlation coefficient [ICC]=.94-.98, all P<.001; coefficient of variation [CV]=2.24-7.94%), although respiratory rate measurement reliability was poor among AF participants (rho=.43, P<.001; ICC=.55, P<.001; CV=16.61%). Data loss was minimal (<5%) when all system components were active; however, instability of the network hosting the remote data capture server resulted in data loss at the remote Internet server during some trials. System validity was sufficient for remote monitoring of heart and respiratory rates across a range of exercise intensities. Remote exercise monitoring has potential to augment current exCR and heart rate control management approaches by enabling the provision of individually tailored care to individuals outside traditional clinical environments. ©Jonathan C Rawstorn, Nicholas Gant, Ian Warren, Robert Neil Doughty, Nigel Lever, Katrina K Poppe, Ralph Maddison. Originally published in JMIR Rehabilitation and Assistive Technology (http://rehab.jmir.org), 20.03.2015.

  12. An applicable approach for extracting human heart rate and oxygen saturation during physical movements using a multi-wavelength illumination optoelectronic sensor system

    NASA Astrophysics Data System (ADS)

    Alharbi, Samah; Hu, Sijung; Mulvaney, David; Blanos, Panagiotis

    2018-02-01

    The ability to gather physiological parameters such as heart rate (HR) and oxygen saturation (SpO2%) during physical movement allows to continuously monitor personal health status without disrupt their normal daily activities. Photoplethysmography (PPG) based pulse oximetry and similar principle devices are unable to extract the HR and SpO2% reliably during physical movement due to interference in the signals that arise from motion artefacts (MAs). In this research, a flexible reflectance multi-wavelength optoelectronic patch sensor (OEPS) has been developed to overcome the susceptibility of conventional pulse oximetry readings to MAs. The OEPS incorporates light embittered diodes as illumination sources with four different wavelengths, e.g. green, orange, red, and infrared unlike the conventional pulse oximetry devices that normally measure the skin absorption of only two wavelengths (red and infrared). The additional green and orange wavelengths were found to be distinguish to the absorption of deoxyhemoglobin (RHb) and oxyhemoglobin (HbO2). The reliability of extracting physiological parameters from the green and orange wavelengths is due to absorbed near to the surface of the skin, thereby shortening the optical path and so effectively reducing the influence of physical movements. To compensate of MAs, a three-axis accelerometer was used as a reference with help of adaptive filter to reduce MAs. The experiments were performed using 15 healthy subjects aged 20 to 30. The primary results show that there are no significant difference of heart rate and oxygen saturation measurements between commercial devices and OEPS Green (r=0.992), Orange(r=0.984), Red(r=0.952) and IR(r=0.97) and SpO2% (r = 0.982, p = 0.894).

  13. A multi-channel opto-electronic sensor to accurately monitor heart rate against motion artefact during exercise.

    PubMed

    Alzahrani, Abdullah; Hu, Sijung; Azorin-Peris, Vicente; Barrett, Laura; Esliger, Dale; Hayes, Matthew; Akbare, Shafique; Achart, Jérôme; Kuoch, Sylvain

    2015-10-12

    This study presents the use of a multi-channel opto-electronic sensor (OEPS) to effectively monitor critical physiological parameters whilst preventing motion artefact as increasingly demanded by personal healthcare. The aim of this work was to study how to capture the heart rate (HR) efficiently through a well-constructed OEPS and a 3-axis accelerometer with wireless communication. A protocol was designed to incorporate sitting, standing, walking, running and cycling. The datasets collected from these activities were processed to elaborate sport physiological effects. t-test, Bland-Altman Agreement (BAA), and correlation to evaluate the performance of the OEPS were used against Polar and Mio-Alpha HR monitors. No differences in the HR were found between OEPS, and either Polar or Mio-Alpha (both p > 0.05); a strong correlation was found between Polar and OEPS (r: 0.96, p < 0.001); the bias of BAA 0.85 bpm, the standard deviation (SD) 9.20 bpm, and the limits of agreement (LOA) from -17.18 bpm to +18.88 bpm. For the Mio-Alpha and OEPS, a strong correlation was found (r: 0.96, p < 0.001); the bias of BAA 1.63 bpm, SD 8.62 bpm, LOA from -15.27 bpm to +18.58 bpm. These results demonstrate the OEPS to be capable of carrying out real time and remote monitoring of heart rate.

  14. Relationships between heart rate and age, bodyweight and breed in 10,849 dogs.

    PubMed

    Hezzell, M J; Dennis, S G; Humm, K; Agee, L; Boswood, A

    2013-06-01

    To evaluate relationships between heart rate and clinical variables in healthy dogs and dogs examined at a referral hospital. Clinical data were extracted from the electronic patient records of a first opinion group (5000 healthy dogs) and a referral hospital (5849 dogs). Univariable and multi-variable general linear models were used to assess associations between heart rate and clinical characteristics. Separate multi-variable models were constructed for first opinion and referral populations. In healthy dogs, heart rate was negatively associated with bodyweight (P<0.001) but was higher in Chihuahuas. The mean difference in heart rate between a 5 and 55 kg dog was 10.5 beats per minute. In dogs presenting to a referral hospital, heart rate was negatively associated with bodyweight (P<0.001) and the following breeds; border collie, golden retriever, Labrador retriever, springer spaniel and West Highland white terrier and positively associated with age, admitting service (emergency and critical care, emergency first opinion and cardiology) and the following breeds; Cavalier King Charles spaniel, Staffordshire bull terrier and Yorkshire terrier. Bodyweight, age, breed and disease status all influence heart rate in dogs, although these factors account for a relatively small proportion of the overall variability in heart rate. © 2013 British Small Animal Veterinary Association.

  15. SVM-Based Spectral Analysis for Heart Rate from Multi-Channel WPPG Sensor Signals.

    PubMed

    Xiong, Jiping; Cai, Lisang; Wang, Fei; He, Xiaowei

    2017-03-03

    Although wrist-type photoplethysmographic (hereafter referred to as WPPG) sensor signals can measure heart rate quite conveniently, the subjects' hand movements can cause strong motion artifacts, and then the motion artifacts will heavily contaminate WPPG signals. Hence, it is challenging for us to accurately estimate heart rate from WPPG signals during intense physical activities. The WWPG method has attracted more attention thanks to the popularity of wrist-worn wearable devices. In this paper, a mixed approach called Mix-SVM is proposed, it can use multi-channel WPPG sensor signals and simultaneous acceleration signals to measurement heart rate. Firstly, we combine the principle component analysis and adaptive filter to remove a part of the motion artifacts. Due to the strong relativity between motion artifacts and acceleration signals, the further denoising problem is regarded as a sparse signals reconstruction problem. Then, we use a spectrum subtraction method to eliminate motion artifacts effectively. Finally, the spectral peak corresponding to heart rate is sought by an SVM-based spectral analysis method. Through the public PPG database in the 2015 IEEE Signal Processing Cup, we acquire the experimental results, i.e., the average absolute error was 1.01 beat per minute, and the Pearson correlation was 0.9972. These results also confirm that the proposed Mix-SVM approach has potential for multi-channel WPPG-based heart rate estimation in the presence of intense physical exercise.

  16. Utility of Time and Frequency Domain Parameters of Heart Rate Variability in the Context of Autonomic Disorders Characterized by Orthostatic Dysfunction.

    PubMed

    Baker, Jacquie; Racosta, Juan M; Balint, Brittany; Kimpinski, Kurt

    2018-03-01

    The clinical significance of heart rate variability in the context of autonomic dysfunction continues to be a matter of debate. A consensus is lacking on the best heart rate variability measures for clinical purposes. Therefore, the purpose of this study was to investigate the utility of heart rate variability parameters in healthy versus autonomic dysfunction. Healthy young (n = 134), healthy older (n = 32), and patients with mild (postural tachycardia syndrome; n = 25) and severe (neurogenic orthostatic hypotension; n = 34) autonomic dysfunction were included. Time and frequency parameters during baseline, head-up tilt (HUT), and heart rate response to deep breathing (HRDB) were compared. Cardiovagal time parameters were significantly reduced during HUT in healthy young and postural tachycardia syndrome (P < 0.001). Healthy young had significantly higher time parameters during baseline, HUT, and HRDB (P < 0.01). This was reflected by a significantly lower resting heart rate (HR) (61.4 ± 9.0 bpm vs. 76.8 ± 13.6 bpm; P < 0.001) and a smaller [INCREMENT]HR during HUT (32.8 ± 10.5 bpm vs. 44.4 ± 13.3 bpm; P < 0.001). Time parameters increased in young and postural tachycardia syndrome during HRDB, which was characterized by a nonsignificant difference in [INCREMENT]HR between both groups. Time parameters were significantly higher in healthy old versus neurogenic orthostatic hypotension at rest and during HRDB (P < 0.05). During HUT, only the SD of all normal RR intervals remained significantly higher. Heart rate changes corroborated these findings. Resting HR was significantly lower in healthy older (62.6 ± 11.0 bpm vs. 70.7 ± 12.4 bpm), and [INCREMENT]HR during HRDB was significantly higher (15.9 ± 9.2 bpm vs. 3.9 ± 4.2 bpm; P < 0.001). During HUT, [INCREMENT]HR showed no significant differences. Time domain parameters of heart rate variability have a greater utility than frequency parameters in clinical autonomic disorders.

  17. 'Multi-associations': predisposed to misinterpretation of peripheral tissue oxygenation and circulation in neonates.

    PubMed

    Pichler, Gerhard; Pocivalnik, Mirjam; Riedl, Regina; Pichler-Stachl, Elisabeth; Morris, Nicholas; Zotter, Heinz; Müller, Wilhelm; Urlesberger, Berndt

    2011-08-01

    Interpretation of peripheral circulation in ill neonates is crucial but difficult. The aim was to analyse parameters potentially influencing peripheral oxygenation and circulation. In a prospective observational cohort study in 116 cardio-circulatory stable neonates, peripheral muscle near-infrared spectroscopy (NIRS) with venous occlusion was performed. Tissue oxygenation index (TOI), mixed venous oxygenation (SvO(2)), fractional oxygen extraction (FOE), fractional tissue oxygen extraction (FTOE), haemoglobin flow (Hbflow), oxygen delivery (DO(2)), oxygen consumption (VO(2)), and vascular resistance (VR) were assessed. Correlation coefficients between NIRS parameters and demographic parameters (gestational age, birth weight, age, actual weight, diameter of calf, subcutaneous adipose tissue), monitoring parameters (heart rate, arterial oxygen saturation (SaO(2)), mean blood pressure (MAP), core/peripheral temperature, central/peripheral capillary refill time) and laboratory parameters (haemoglobin concentration (Hb-blood), pCO(2)) were calculated. All demographic parameters except for Hbflow and DO(2) correlated with NIRS parameters. Heart rate correlated with TOI, SvO(2), VO(2) and VR. SaO(2) correlated with FOE/FTOE. MAP correlated with Hbflow, DO(2), VO(2) and VR. Core temperature correlated with FTOE. Peripheral temperature correlated with all NIRS parameters except VO(2). Hb-blood correlated with FOE and VR. pCO(2) levels correlated with TOI and SvO(2). The presence of multiple interdependent factors associated with peripheral oxygenation and circulation highlights the difficulty in interpreting NIRS data. Nevertheless, these findings have to be taken into account when analysing peripheral oxygenation and circulation data.

  18. Relationships between QT interval and heart rate variability at rest and the covariates in healthy young adults.

    PubMed

    Arai, Kaori; Nakagawa, Yui; Iwata, Toyoto; Horiguchi, Hyogo; Murata, Katsuyuki

    2013-01-01

    To clarify the links between ECG QT-related parameters and heart rate variability (HRV) and the covariates possibly distorting them, the averaged RR and QT intervals in a single lead ECG were measured for 64 male and 86 female subjects aged 18-26. The QT index, defined by Rautaharju et al., in the young adults was not significantly related to any HRV parameters nor heart rate, but the Bazett's corrected QT (QTc) interval was associated negatively with the parasympathetic activity and positively with heart rate. No significant differences in the QTc interval, QT index or heart rate were seen between the men and women, but they significantly differed between both sexes after adjustment for possible covariates such as age and body mass index (BMI). Significant sex differences in parasympathetic parameters of the HRV were unchanged before and after the adjustment, but significant differences observed in the unadjusted sympathetic parameters disappeared after adjusting for covariates. Age, BMI and body fat percentage also were significant covariates affecting these ECG parameters. Consequently, QT index, unaffected by heart rate and HRV parameters, appears to be a more useful indicator than the QTc interval. Instead, the QT index and HRV parameters are recommended to be simultaneously measured in epidemiological research because they are probably complementary in assessing autonomic nervous function. Also, these parameters should be analyzed in men and women separately. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Heart rate differentiates urgency and emergency in hypertensive crisis.

    PubMed

    Al Bannay, Rashed; Böhm, Michael; Husain, Aysha

    2013-08-01

    To study the clinical significance of presenting blood pressure parameters and heart rate in patients with hypertensive crisis. In patients admitted with hypertensive crisis between January 2011 and May 2011, demography, mode of presentation, co-morbidities, blood pressure readings, and heart rate at presentation were documented. Further clustering of hypertensive crisis into emergency or urgency was based on the presence or absence of target organ involvement. The relationship between blood pressure parameters, heart rate, and other variables was analyzed. 189 patients in sinus rhythm were enrolled in this pilot study. The rate of hypertensive urgency was 56 %, whereas the rate of hypertensive emergency was 44 %, respectively. Subjects with hypertensive emergency had a higher mean heart rate (93 ± 22.7 bpm) than those with urgency (81 ± 11.5 bpm) (P = 0.015). Women had higher heart rates (92 ± 18.5 bpm) than men (86 ± 17.6 bpm) (P = 0.014). Heart rates below 100 bpm had a specificity of 94 %, classifying patients as hypertensive urgency. Tachycardia had a powerful statistical association with hypertensive left ventricular failure (P < 0.0001). Other hemodynamic parameters, including systolic blood pressure, diastolic blood pressure, pulse pressure, and mean blood pressure relates neither to urgency nor to emergency. Diabetic patients with HBA1c levels of more than 53 mmol/mol had a heart rate of more than 100 bpm (P = 0.015) during hypertensive crisis. Normal heart rate is characteristic of hypertensive urgency. Tachycardia in this setting is an ominous sign and denotes hypertensive complications in particular left ventricular failure. Among diabetics, elevated heart rate is associated with poor glycemic control.

  20. Using Renyi entropy to detect early cardiac autonomic neuropathy.

    PubMed

    Cornforth, David J; Tarvainen, Mika P; Jelinek, Herbert F

    2013-01-01

    Cardiac Autonomic Neuropathy (CAN) is a disease that involves nerve damage leading to abnormal control of heart rate. CAN affects the correct operation of the heart and in turn leads to associated arrhythmias and heart attack. An open question is to what extent this condition is detectable by the measurement of Heart Rate Variability (HRV). An even more desirable option is to detect CAN in its early, preclinical stage, to improve treatment and outcomes. In previous work we have shown a difference in the Renyi spectrum between participants identified with well-defined CAN and controls. In this work we applied the multi-scale Renyi entropy for identification of early CAN in diabetes patients. Results suggest that Renyi entropy derived from a 20 minute, Lead-II ECG recording, forms a useful contribution to the detection of CAN even in the early stages of the disease. The positive α parameters (1 ≤ α ≤ 5) associated with the Renyi distribution indicated a significant difference (p < 0.00004) between controls and early CAN as well as definite CAN. This is a significant achievement given the simple nature of the information collected, and raises prospects of a simple screening test and improved outcomes of patients.

  1. Novel application of multi dynamic trend analysis as a sensitive tool for detecting the effects of aging and congestive heart failure on heart rate variability

    NASA Astrophysics Data System (ADS)

    Lin, Yu-Cheng; Lin, Yu-Hsuan; Lo, Men-Tzung; Peng, Chung-Kang; Huang, Norden E.; Yang, Cheryl C. H.; Kuo, Terry B. J.

    2016-02-01

    The complex fluctuations in heart rate variability (HRV) reflect cardiac autonomic modulation and are an indicator of congestive heart failure (CHF). This paper proposes a novel nonlinear approach to HRV investigation, the multi dynamic trend analysis (MDTA) method, based on the empirical mode decomposition algorithm of the Hilbert-Huang transform combined with a variable-sized sliding-window method. Electrocardiographic signal data obtained from the PhysioNet database were used. These data were from subjects with CHF (mean age = 59.4 ± 8.4), an age-matched elderly healthy control group (59.3 ± 10.6), and a healthy young group (30.3 ± 4.8); the HRVs of these subjects were processed using the MDTA method, time domain analysis, and frequency domain analysis. Among all HRV parameters, the MDTA absolute value slope (MDTS) and MDTA deviation (MDTD) exhibited the greatest area under the curve (AUC) of the receiver operating characteristics in distinguishing between the CHF group and the healthy controls (AUC = 1.000) and between the healthy elderly subject group and the young subject group (AUC = 0.834 ± 0.067 for MDTS; 0.837 ± 0.066 for MDTD). The CHF subjects presented with lower MDTA indices than those of the healthy elderly subject group. Furthermore, the healthy elderly subjects exhibited lower MDTA indices than those of the young controls. The MDTA method can adaptively and automatically identify the intrinsic fluctuation on variable temporal and spatial scales when investigating complex fluctuations in the cardiac autonomic regulation effects of aging and CHF.

  2. [Design of hand-held heart rate variability acquisition and analysis system].

    PubMed

    Li, Kaiyuan; Wang, Buqing; Wang, Weidong

    2012-07-01

    A design of handheld heart rate variability acquisition and analysis system is proposed. The system collects and stores the patient's ECG every five minutes through both hands touching on the electrodes, and then -uploads data to a PC through USB port. The system uses software written in LabVIEW to analyze heart rate variability parameters, The parameters calculated function is programmed and generated to components in Matlab.

  3. The use of heart rate turbulence and heart rate variability in the assessment of autonomic regulation and circadian rhythm in patients with systemic lupus erythematosus without apparent heart disease.

    PubMed

    Poliwczak, A R; Waszczykowska, E; Dziankowska-Bartkowiak, B; Koziróg, M; Dworniak, K

    2018-03-01

    Background Systemic lupus erythematosus is a progressive autoimmune disease. There are reports suggesting that patients even without overt signs of cardiovascular complications have impaired autonomic function. The aim of this study was to assess autonomic function using heart rate turbulence and heart rate variability parameters indicated in 24-hour ECG Holter monitoring. Methods Twenty-six women with systemic lupus erythematosus and 30 healthy women were included. Twenty-four hour ambulatory ECG-Holter was performed in home conditions. The basic parameters of heart rate turbulence and heart rate variability were calculated. The analyses were performed for the entire day and separately for daytime activity and night time rest. Results There were no statistically significant differences in the basic anthropometric parameters. The mean duration of disease was 11.52 ± 7.42. There was a statistically significant higher turbulence onset (To) value in patients with systemic lupus erythematosus, median To = -0.17% (minimum -1.47, maximum 3.0) versus To = -1.36% (minimum -4.53, maximum -0.41), P < 0.001. There were no such differences for turbulence slope (Ts). In the 24-hour analysis almost all heart rate variability parameters were significantly lower in the systemic lupus erythematosus group than in the healthy controls, including SDANN and r-MSSD and p50NN. Concerning the morning activity and night resting periods, the results were similar as for the whole day. In the control group, higher values in morning activity were noted for parameters that characterise sympathetic activity, especially SDANN, and were significantly lower for parasympathetic parameters, including r-MSSD and p50NN, which prevailed at night. There were no statistically significant changes for systemic lupus erythematosus patients for p50NN and low and very low frequency. There was a positive correlation between disease duration and SDNN, R = 0.417; P < 0.05 and SDANN, R = 0.464; P < 0.05, a negative correlation between low/high frequency ratio and r-MSSD, R = -0.454; P < 0.05; p50NN, R = -0.435; P < 0.05 and high frequency, R = -0.478; P < 0.05. In contrast, there was no statistically significant correlation between heart rate turbulence and other variables evaluated, including disease duration and the type of autoantibodies. Our study confirms the presence of autonomic disorders with respect to both heart rate variability and heart rate turbulence parameters and the presence of diurnal disturbances of sympathetic-parasympathetic balance. Further studies are required.

  4. Estimation of body temperature rhythm based on heart activity parameters in daily life.

    PubMed

    Sooyoung Sim; Heenam Yoon; Hosuk Ryou; Kwangsuk Park

    2014-01-01

    Body temperature contains valuable health related information such as circadian rhythm and menstruation cycle. Also, it was discovered from previous studies that body temperature rhythm in daily life is related with sleep disorders and cognitive performances. However, monitoring body temperature with existing devices during daily life is not easy because they are invasive, intrusive, or expensive. Therefore, the technology which can accurately and nonintrusively monitor body temperature is required. In this study, we developed body temperature estimation model based on heart rate and heart rate variability parameters. Although this work was inspired by previous research, we originally identified that the model can be applied to body temperature monitoring in daily life. Also, we could find out that normalized Mean heart rate (nMHR) and frequency domain parameters of heart rate variability showed better performance than other parameters. Although we should validate the model with more number of subjects and consider additional algorithms to decrease the accumulated estimation error, we could verify the usefulness of this approach. Through this study, we expect that we would be able to monitor core body temperature and circadian rhythm from simple heart rate monitor. Then, we can obtain various health related information derived from daily body temperature rhythm.

  5. Association of heart rate profile during exercise with the severity of coronary artery disease.

    PubMed

    Cay, Serkan; Ozturk, Sezgin; Biyikoglu, Funda; Yildiz, Abdulkadir; Cimen, Tolga; Uygur, Belma; Tuna, Funda

    2009-05-01

    Coronary artery disease is the leading cause of morbidity and mortality around the world. Autonomic nervous system abnormalities are associated with coronary artery disease and its complications. Exercise stress tests are routinely used for the detection of the presence of coronary artery disease. In this study, we observed the association between heart rate profile during exercise and the severity of coronary artery disease. One hundred and sixty patients with abnormal exercise treadmill test (> or =1 mm horizontal or downsloping ST-segment depression; 119 men, 41 women; mean age = 57 +/- 9 years) were included in the study. Use of any drug affecting heart rate was not permitted. Resting heart rate before exercise, maximum heart rate during exercise, and resting heart rate after exercise (5 min later) were measured and two parameters were calculated: heart rate increment (maximum heart rate - resting heart rate before exercise) and heart rate decrement (maximum heart rate - resting heart rate after exercise). All patients underwent selective coronary angiography and subclassified into two groups according to stenotic lesion severity. Group 1 had at least 50% of stenotic lesion and group 2 had less than 50%. Patients in the first group had increased resting heart rate, decreased maximum heart rate, decreased heart rate increment, and decreased heart rate decrement compared with second group. All patients were classified into tertiles of resting heart rate, heart rate increment, and heart rate decrement level to evaluate whether these parameters were associated with severity of coronary artery stenosis in the study. The multiple-adjusted odds ratio of the risk of severe coronary atherosclerosis was 21.888 (95% confidence interval 6.983-68.606) for the highest tertile of resting heart rate level compared with the lowest tertile. In addition, the multiple-adjusted odds ratio of the risk of severe coronary atherosclerosis was 20.987 (95% confidence interval 6.635-66.387) for the lowest tertile of heart rate increment level compared with the highest tertile and 2.360 (95% confidence interval 1.004-5.544) for the lowest tertile of heart rate decrement level compared with the highest tertile. Altered autonomic nervous system regulation affects heart rate profile, increased resting heart rate, decreased heart rate increment, and decreased heart rate decrement, during exercise and this effect is strongly and independently associated with the severity of coronary artery disease.

  6. Relation of Heart Rate and its Variability during Sleep with Age, Physical Activity, and Body Composition in Young Children

    PubMed Central

    Herzig, David; Eser, Prisca; Radtke, Thomas; Wenger, Alina; Rusterholz, Thomas; Wilhelm, Matthias; Achermann, Peter; Arhab, Amar; Jenni, Oskar G.; Kakebeeke, Tanja H.; Leeger-Aschmann, Claudia S.; Messerli-Bürgy, Nadine; Meyer, Andrea H.; Munsch, Simone; Puder, Jardena J.; Schmutz, Einat A.; Stülb, Kerstin; Zysset, Annina E.; Kriemler, Susi

    2017-01-01

    Background: Recent studies have claimed a positive effect of physical activity and body composition on vagal tone. In pediatric populations, there is a pronounced decrease in heart rate with age. While this decrease is often interpreted as an age-related increase in vagal tone, there is some evidence that it may be related to a decrease in intrinsic heart rate. This factor has not been taken into account in most previous studies. The aim of the present study was to assess the association between physical activity and/or body composition and heart rate variability (HRV) independently of the decline in heart rate in young children. Methods: Anthropometric measurements were taken in 309 children aged 2–6 years. Ambulatory electrocardiograms were collected over 14–18 h comprising a full night and accelerometry over 7 days. HRV was determined of three different night segments: (1) over 5 min during deep sleep identified automatically based on HRV characteristics; (2) during a 20 min segment starting 15 min after sleep onset; (3) over a 4-h segment between midnight and 4 a.m. Linear models were computed for HRV parameters with anthropometric and physical activity variables adjusted for heart rate and other confounding variables (e.g., age for physical activity models). Results: We found a decline in heart rate with increasing physical activity and decreasing skinfold thickness. HRV parameters decreased with increasing age, height, and weight in HR-adjusted regression models. These relationships were only found in segments of deep sleep detected automatically based on HRV or manually 15 min after sleep onset, but not in the 4-h segment with random sleep phases. Conclusions: Contrary to most previous studies, we found no increase of standard HRV parameters with age, however, when adjusted for heart rate, there was a significant decrease of HRV parameters with increasing age. Without knowing intrinsic heart rate correct interpretation of HRV in growing children is impossible. PMID:28286485

  7. Relation of Heart Rate and its Variability during Sleep with Age, Physical Activity, and Body Composition in Young Children.

    PubMed

    Herzig, David; Eser, Prisca; Radtke, Thomas; Wenger, Alina; Rusterholz, Thomas; Wilhelm, Matthias; Achermann, Peter; Arhab, Amar; Jenni, Oskar G; Kakebeeke, Tanja H; Leeger-Aschmann, Claudia S; Messerli-Bürgy, Nadine; Meyer, Andrea H; Munsch, Simone; Puder, Jardena J; Schmutz, Einat A; Stülb, Kerstin; Zysset, Annina E; Kriemler, Susi

    2017-01-01

    Background: Recent studies have claimed a positive effect of physical activity and body composition on vagal tone. In pediatric populations, there is a pronounced decrease in heart rate with age. While this decrease is often interpreted as an age-related increase in vagal tone, there is some evidence that it may be related to a decrease in intrinsic heart rate. This factor has not been taken into account in most previous studies. The aim of the present study was to assess the association between physical activity and/or body composition and heart rate variability (HRV) independently of the decline in heart rate in young children. Methods: Anthropometric measurements were taken in 309 children aged 2-6 years. Ambulatory electrocardiograms were collected over 14-18 h comprising a full night and accelerometry over 7 days. HRV was determined of three different night segments: (1) over 5 min during deep sleep identified automatically based on HRV characteristics; (2) during a 20 min segment starting 15 min after sleep onset; (3) over a 4-h segment between midnight and 4 a.m. Linear models were computed for HRV parameters with anthropometric and physical activity variables adjusted for heart rate and other confounding variables (e.g., age for physical activity models). Results: We found a decline in heart rate with increasing physical activity and decreasing skinfold thickness. HRV parameters decreased with increasing age, height, and weight in HR-adjusted regression models. These relationships were only found in segments of deep sleep detected automatically based on HRV or manually 15 min after sleep onset, but not in the 4-h segment with random sleep phases. Conclusions: Contrary to most previous studies, we found no increase of standard HRV parameters with age, however, when adjusted for heart rate, there was a significant decrease of HRV parameters with increasing age. Without knowing intrinsic heart rate correct interpretation of HRV in growing children is impossible.

  8. Heart rate variability as determinism with jump stochastic parameters.

    PubMed

    Zheng, Jiongxuan; Skufca, Joseph D; Bollt, Erik M

    2013-08-01

    We use measured heart rate information (RR intervals) to develop a one-dimensional nonlinear map that describes short term deterministic behavior in the data. Our study suggests that there is a stochastic parameter with persistence which causes the heart rate and rhythm system to wander about a bifurcation point. We propose a modified circle map with a jump process noise term as a model which can qualitatively capture such this behavior of low dimensional transient determinism with occasional (stochastically defined) jumps from one deterministic system to another within a one parameter family of deterministic systems.

  9. A novel LabVIEW-based multi-channel non-invasive abdominal maternal-fetal electrocardiogram signal generator.

    PubMed

    Martinek, Radek; Kelnar, Michal; Koudelka, Petr; Vanus, Jan; Bilik, Petr; Janku, Petr; Nazeran, Homer; Zidek, Jan

    2016-02-01

    This paper describes the design, construction, and testing of a multi-channel fetal electrocardiogram (fECG) signal generator based on LabVIEW. Special attention is paid to the fetal heart development in relation to the fetus' anatomy, physiology, and pathology. The non-invasive signal generator enables many parameters to be set, including fetal heart rate (FHR), maternal heart rate (MHR), gestational age (GA), fECG interferences (biological and technical artifacts), as well as other fECG signal characteristics. Furthermore, based on the change in the FHR and in the T wave-to-QRS complex ratio (T/QRS), the generator enables manifestations of hypoxic states (hypoxemia, hypoxia, and asphyxia) to be monitored while complying with clinical recommendations for classifications in cardiotocography (CTG) and fECG ST segment analysis (STAN). The generator can also produce synthetic signals with defined properties for 6 input leads (4 abdominal and 2 thoracic). Such signals are well suited to the testing of new and existing methods of fECG processing and are effective in suppressing maternal ECG while non-invasively monitoring abdominal fECG. They may also contribute to the development of a new diagnostic method, which may be referred to as non-invasive trans-abdominal CTG +  STAN. The functional prototype is based on virtual instrumentation using the LabVIEW developmental environment and its associated data acquisition measurement cards (DAQmx). The generator also makes it possible to create synthetic signals and measure actual fetal and maternal ECGs by means of bioelectrodes.

  10. A low cost implementation of multi-parameter patient monitor using intersection kernel support vector machine classifier

    NASA Astrophysics Data System (ADS)

    Mohan, Dhanya; Kumar, C. Santhosh

    2016-03-01

    Predicting the physiological condition (normal/abnormal) of a patient is highly desirable to enhance the quality of health care. Multi-parameter patient monitors (MPMs) using heart rate, arterial blood pressure, respiration rate and oxygen saturation (S pO2) as input parameters were developed to monitor the condition of patients, with minimum human resource utilization. The Support vector machine (SVM), an advanced machine learning approach popularly used for classification and regression is used for the realization of MPMs. For making MPMs cost effective, we experiment on the hardware implementation of the MPM using support vector machine classifier. The training of the system is done using the matlab environment and the detection of the alarm/noalarm condition is implemented in hardware. We used different kernels for SVM classification and note that the best performance was obtained using intersection kernel SVM (IKSVM). The intersection kernel support vector machine classifier MPM has outperformed the best known MPM using radial basis function kernel by an absoute improvement of 2.74% in accuracy, 1.86% in sensitivity and 3.01% in specificity. The hardware model was developed based on the improved performance system using Verilog Hardware Description Language and was implemented on Altera cyclone-II development board.

  11. Long-Term Coarse Particulate Matter Exposure and Heart Rate Variability in the Multi-Ethnic Study of Atherosclerosis (MESA)

    PubMed Central

    Adhikari, Richa; D’Souza, Jennifer; Solimon, Elsayed Z.; Burke, Gregory L.; Daviglus, Martha; Jacobs, David R.; Park, Sung Kyun; Sheppard, Lianne; Thorne, Peter S.; Kaufman, Joel D.; Larson, Timothy V.; Adar, Sara D.

    2017-01-01

    Background Reduced heart rate variability, a marker of impaired cardiac autonomic function, has been linked to short-term exposure to airborne particles. This research adds to the literature by examining associations with long-term exposures to coarse particles (PM10-2.5). Methods Using electrocardiogram recordings from 2,780 participants (45-84 years) from three Multi-Ethnic Study of Atherosclerosis sites, we assessed the standard deviation of normal-to-normal intervals (SDNN) and root-mean square differences of successive normal-to-normal intervals (rMSSD) at a baseline (2000-2002) and follow-up (2010-2012) examination (mean visits/person=1.5). Annual average concentrations of PM10-2.5 mass, copper, zinc, phosphorus, silicon, and endotoxin were estimated using site-specific spatial prediction models. We assessed associations for baseline heart rate variability and rate of change in heart rate variability over time using multivariable mixed models adjusted for time, sociodemographic, lifestyle, health, and neighborhood confounders, including co-pollutants. Results In our primary models adjusted for demographic and lifestyle factors and site, PM10-2.5 mass was associated with 1.0% (95% CI: -4.1, 2.1%) lower SDNN levels per interquartile range of 2 μg/m3. Stronger associations, however, were observed prior to site adjustment and with increasing residential stablity. Similar patterns were found for rMSSD. We found little evidence for associations with other chemical species and with with the rate of change in heart rate variability, though endotoxin was associated with increasing heart rate variability over time. Conclusion We found only weak evidence that long-term PM10-2.5 exposures are associated with lowered heart rate variability. Stronger associations among residentially stable individuals suggest that confirmatory studies are needed. PMID:27035690

  12. Heart Rate and Respiratory Rate Influence on Heart Rate Variability Repeatability: Effects of the Correction for the Prevailing Heart Rate

    PubMed Central

    Gąsior, Jakub S.; Sacha, Jerzy; Jeleń, Piotr J.; Zieliński, Jakub; Przybylski, Jacek

    2016-01-01

    Background: Since heart rate variability (HRV) is associated with average heart rate (HR) and respiratory rate (RespRate), alterations in these parameters may impose changes in HRV. Hence the repeatability of HRV measurements may be affected by differences in HR and RespRate. The study aimed to evaluate HRV repeatability and its association with changes in HR and RespRate. Methods: Forty healthy volunteers underwent two ECG examinations 7 days apart. Standard HRV indices were calculated from 5-min ECG recordings. The ECG-derived respiration signal was estimated to assess RespRate. To investigate HR impact on HRV, HRV parameters were corrected for prevailing HR. Results: Differences in HRV parameters between the measurements were associated with the changes in HR and RespRate. However, in multiple regression analysis only HR alteration proved to be independent determinant of the HRV differences—every change in HR by 1 bpm changed HRV values by 16.5% on average. After overall removal of HR impact on HRV, coefficients of variation of the HRV parameters significantly dropped on average by 26.8% (p < 0.001), i.e., by the same extent HRV reproducibility improved. Additionally, the HRV correction for HR decreased association between RespRate and HRV. Conclusions: In stable conditions, HR but not RespRate is the most powerful factor determining HRV reproducibility and even a minimal change of HR may considerably alter HRV. However, the removal of HR impact may significantly improve HRV repeatability. The association between HRV and RespRate seems to be, at least in part, HR dependent. PMID:27588006

  13. [The functional state classification and evaluation of the stability level in mental loads based on the factor structure of heart rate variability parameters].

    PubMed

    Mashin, V A; Mashina, M N

    2004-12-01

    In the paper, outcomes of the researches devoted to factor analysis of heart rate variability parameters and definition of the most informative parameters for diagnostics of functional states and an evaluation of level of stability to mental loads, are presented. The factor structure of parameters, which unclude integral level of heart rate variability (1), balance between activity of vagus and brain cortical-limbic systems (2), integrated level of cardiovascular system functioning (3), is substantiated. Factor analysis outcomes have been used for construction of functional state classification, for their differential diagnostics, and for development and check of algorithm for evaluation of the stability level in mental loads.

  14. Heart Rate and Reinforcement Sensitivity in ADHD

    ERIC Educational Resources Information Center

    Luman, Marjolein; Oosterlaan, Jaap; Hyde, Christopher; van Meel, Catharina S.; Sergeant, Joseph A.

    2007-01-01

    Background: Both theoretical and clinical accounts of attention-deficit/hyperactivity disorder (ADHD) implicate a dysfunctional reinforcement system. This study investigated heart rate parameters in response to feedback associated with reward and response cost in ADHD children and controls aged 8 to 12. Methods: Heart rate responses (HRRs)…

  15. Understanding heart rate alarm adjustment in the intensive care units through an analytical approach.

    PubMed

    Fidler, Richard L; Pelter, Michele M; Drew, Barbara J; Palacios, Jorge Arroyo; Bai, Yong; Stannard, Daphne; Aldrich, J Matt; Hu, Xiao

    2017-01-01

    Heart rate (HR) alarms are prevalent in ICU, and these parameters are configurable. Not much is known about nursing behavior associated with tailoring HR alarm parameters to individual patients to reduce clinical alarm fatigue. To understand the relationship between heart rate (HR) alarms and adjustments to reduce unnecessary heart rate alarms. Retrospective, quantitative analysis of an adjudicated database using analytical approaches to understand behaviors surrounding parameter HR alarm adjustments. Patients were sampled from five adult ICUs (77 beds) over one month at a quaternary care university medical center. A total of 337 of 461 ICU patients had HR alarms with 53.7% male, mean age 60.3 years, and 39% non-Caucasian. Default HR alarm parameters were 50 and 130 beats per minute (bpm). The occurrence of each alarm, vital signs, and physiologic waveforms was stored in a relational database (SQL server). There were 23,624 HR alarms for analysis, with 65.4% exceeding the upper heart rate limit. Only 51% of patients with HR alarms had parameters adjusted, with a median upper limit change of +5 bpm and -1 bpm lower limit. The median time to first HR parameter adjustment was 17.9 hours, without reduction in alarms occurrence (p = 0.57). HR alarms are prevalent in ICU, and half of HR alarm settings remain at default. There is a long delay between HR alarms and parameters changes, with insufficient changes to decrease HR alarms. Increasing frequency of HR alarms shortens the time to first adjustment. Best practice guidelines for HR alarm limits are needed to reduce alarm fatigue and improve monitoring precision.

  16. A protocol to study ex vivo mouse working heart at human-like heart rate.

    PubMed

    Feng, Han-Zhong; Jin, Jian-Ping

    2018-01-01

    Genetically modified mice are widely used as experimental models to study human heart function and diseases. However, the fast rate of normal mouse heart at 400-600bpm limits its capacity of assessing kinetic parameters that are important for the physiology and pathophysiology of human heart that beats at a much slower rate (75-180bpm). To extend the value of mouse models, we established a protocol to study ex vivo mouse working hearts at a human-like heart rate. In the presence of 300μM lidocaine to lower pacemaker and conductive activities and prevent arrhythmia, a stable rate of 120-130bpm at 37°C is achieved for ex vivo mouse working hearts. The negative effects of decreased heart rate on force-frequency dependence and lidocaine as a myocardial depressant on intracellular calcium can be compensated by using a higher but still physiological level of calcium (2.75mM) in the perfusion media. Multiple parameters were studied to compare the function at the human-like heart rate with that of ex vivo mouse working hearts at the standard rate of 480bpm. The results showed that the conditions for slower heart rate in the presence of 300μM lidocaine did not have depressing effect on left ventricular pressure development, systolic and diastolic velocities and stroke volume with maintained positive inotropic and lusitropic responses to β-adrenergic stimulation. Compared with that at 480bpm, the human-like heart rate increased ventricular filling and end diastolic volume with enhanced Frank-Starling responses. Coronary perfusion was increased from longer relaxation time and interval between beats whereas cardiac efficiency was significantly improved. Although the intrinsic differences between mouse and human heart remain, this methodology for ex vivo mouse hearts to work at human-like heart rate extends the value of using genetically modified mouse models to study cardiac function and human heart diseases. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Understanding heart rate alarm adjustment in the intensive care units through an analytical approach

    PubMed Central

    Pelter, Michele M.; Drew, Barbara J.; Palacios, Jorge Arroyo; Bai, Yong; Stannard, Daphne; Aldrich, J. Matt; Hu, Xiao

    2017-01-01

    Background Heart rate (HR) alarms are prevalent in ICU, and these parameters are configurable. Not much is known about nursing behavior associated with tailoring HR alarm parameters to individual patients to reduce clinical alarm fatigue. Objectives To understand the relationship between heart rate (HR) alarms and adjustments to reduce unnecessary heart rate alarms. Methods Retrospective, quantitative analysis of an adjudicated database using analytical approaches to understand behaviors surrounding parameter HR alarm adjustments. Patients were sampled from five adult ICUs (77 beds) over one month at a quaternary care university medical center. A total of 337 of 461 ICU patients had HR alarms with 53.7% male, mean age 60.3 years, and 39% non-Caucasian. Default HR alarm parameters were 50 and 130 beats per minute (bpm). The occurrence of each alarm, vital signs, and physiologic waveforms was stored in a relational database (SQL server). Results There were 23,624 HR alarms for analysis, with 65.4% exceeding the upper heart rate limit. Only 51% of patients with HR alarms had parameters adjusted, with a median upper limit change of +5 bpm and -1 bpm lower limit. The median time to first HR parameter adjustment was 17.9 hours, without reduction in alarms occurrence (p = 0.57). Conclusions HR alarms are prevalent in ICU, and half of HR alarm settings remain at default. There is a long delay between HR alarms and parameters changes, with insufficient changes to decrease HR alarms. Increasing frequency of HR alarms shortens the time to first adjustment. Best practice guidelines for HR alarm limits are needed to reduce alarm fatigue and improve monitoring precision. PMID:29176776

  18. Effects of foot reflexology on anxiety and physiological parameters in patients undergoing coronary artery bypass graft surgery: A clinical trial.

    PubMed

    Abbaszadeh, Yaser; Allahbakhshian, Atefeh; Seyyedrasooli, Alehe; Sarbakhsh, Parvin; Goljarian, Sakineh; Safaei, Naser

    2018-05-01

    This study aimed to investigate the effect of foot reflexology on anxiety and physiological parameters in patients after CABG surgery. This was a single-blind, three-arm, parallel-group, randomized controlled trial with three groups of 40 male patients undergoing CABG. Participants were placed in three groups, named intervention, placebo, and control. Physiological parameters were measured including systolic and diastolic blood pressure, mean arterial pressure, heart rate, respiratory rate, percutaneous oxygen saturation, and anxiety of participants. Results showed a statistically significant difference between intervention and control groups in terms of the level of anxiety (p < 0.05). Also, results showed a statistically significant effect on all physiological parameters except heart rate (p < 0.05). This study indicated that foot reflexology may be used by nurses as an adjunct to standard ICU care to reduce anxiety and stabilize physiological parameters such as systolic, diastolic, mean arterial pressure, and heart rate. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Heart rate variability in normal-weight patients with polycystic ovary syndrome.

    PubMed

    Kilit, Celal; Paşalı Kilit, Türkan

    2017-05-01

    Polycystic ovary syndrome (PCOS) is an endocrine disease closely related to several risk factors of cardiovascular disease. Obese women with PCOS show altered autonomic modulation. The results of studies investigating cardiac autonomic functions of normal-weight women with PCOS are conflicting. The aim of the study was to assess the reactivity of cardiac sympathovagal balance in normal-weight women with PCOS by heart rate variability analysis. We examined the heart rate variability in 60 normal-weight women with PCOS and compared them with that in 60 age-matched healthy women having a similar metabolic profile. Time and frequency domain parameters of heart rate variability were analyzed based on 5-min-long continuous electrocardiography recordings for the following 3 periods: (1) during rest in supine position, (2) during controlled breathing, and (3) during isometric handgrip exercise. Time and frequency domain parameters of heart rate variability for the 3 periods assessed were similar in the two groups. Although modified Ferriman-Gallwey score and serum testosterone and luteinizing hormone levels were significantly higher in women with PCOS, homeostatic model assessment-insulin resistance (HOMA-IR) was not different the between the PCOS and control groups. There were no significant correlations between serum testosterone levels and heart rate variability parameters among the study population. The findings of this study suggest that the reactivity of cardiac sympathovagal balance is not altered in normal-weight women with PCOS having a normal HOMA-IR.

  20. Estimation of heart rate and heart rate variability from pulse oximeter recordings using localized model fitting.

    PubMed

    Wadehn, Federico; Carnal, David; Loeliger, Hans-Andrea

    2015-08-01

    Heart rate variability is one of the key parameters for assessing the health status of a subject's cardiovascular system. This paper presents a local model fitting algorithm used for finding single heart beats in photoplethysmogram recordings. The local fit of exponentially decaying cosines of frequencies within the physiological range is used to detect the presence of a heart beat. Using 42 subjects from the CapnoBase database, the average heart rate error was 0.16 BPM and the standard deviation of the absolute estimation error was 0.24 BPM.

  1. Multi-parameter vital sign database to assist in alarm optimization for general care units.

    PubMed

    Welch, James; Kanter, Benjamin; Skora, Brooke; McCombie, Scott; Henry, Isaac; McCombie, Devin; Kennedy, Rosemary; Soller, Babs

    2016-12-01

    Continual vital sign assessment on the general care, medical-surgical floor is expected to provide early indication of patient deterioration and increase the effectiveness of rapid response teams. However, there is concern that continual, multi-parameter vital sign monitoring will produce alarm fatigue. The objective of this study was the development of a methodology to help care teams optimize alarm settings. An on-body wireless monitoring system was used to continually assess heart rate, respiratory rate, SpO 2 and noninvasive blood pressure in the general ward of ten hospitals between April 1, 2014 and January 19, 2015. These data, 94,575 h for 3430 patients are contained in a large database, accessible with cloud computing tools. Simulation scenarios assessed the total alarm rate as a function of threshold and annunciation delay (s). The total alarm rate of ten alarms/patient/day predicted from the cloud-hosted database was the same as the total alarm rate for a 10 day evaluation (1550 h for 36 patients) in an independent hospital. Plots of vital sign distributions in the cloud-hosted database were similar to other large databases published by different authors. The cloud-hosted database can be used to run simulations for various alarm thresholds and annunciation delays to predict the total alarm burden experienced by nursing staff. This methodology might, in the future, be used to help reduce alarm fatigue without sacrificing the ability to continually monitor all vital signs.

  2. The predictive value of resting heart rate following osmotherapy in brain injury: back to basics.

    PubMed

    Hasanpour Mir, Mahsa; Yousefshahi, Fardin; Abdollahi, Mohammad; Ahmadi, Arezoo; Nadjafi, Atabak; Mojtahedzadeh, Mojtaba

    2012-12-30

    The importance of resting heart rate as a prognostic factor was described in several studies. An elevated heart rate is an independent risk factor for adverse cardiovascular events and total mortality in patients with coronary artery disease, chronic heart failure, and the general population. Also heart rate is elevated in the Multi Organ Dysfunction Syndrome (MODS) and the mortality due to MODS is highly correlated with inadequate sinus tachycardia.To evaluate the value of resting heart rate in predicting mortality in patients with traumatic brain injury along scoring systems like Acute Physiology and Chronic Health Evaluation(APACHE II), Sequential Organ Failure Assessment (SOFA) and Glasgow Coma Score (GCS). By analyzing data which was collected from an open labeled randomized clinical trial that compared the different means of osmotherapy (mannitol vs bolus or infusion hypertonic saline), heart rate, GCS, APACHE II and SOFA score were measured at baseline and daily for 7 days up to 60 days and the relationship between elevated heart rate and mortality during the first 7 days and 60th day were assessed. After adjustments for confounding factors, although there was no difference in mean heart rate between either groups of alive and expired patients, however, we have found a relative correlation between 60th day mortality rate and resting heart rate (P=0.07). Heart rate can be a prognostic factor for estimating mortality rate in brain injury patients along with APACHE II and SOFA scores in patients with brain injury.

  3. A 4-Week Intervention Involving Mobile-Based Daily 6-Minute Micro-Sessions of Functional High-Intensity Circuit Training Improves Strength and Quality of Life, but Not Cardio-Respiratory Fitness of Young Untrained Adults.

    PubMed

    Sperlich, Billy; Hahn, Lea-Sofie; Edel, Antonia; Behr, Tino; Helmprobst, Julian; Leppich, Robert; Wallmann-Sperlich, Birgit; Holmberg, Hans-Christer

    2018-01-01

    The present study was designed to assess the psycho-physiological responses of physically untrained individuals to mobile-based multi-stimulating, circuit-like, multiple-joint conditioning (Circuit HIIT ) performed either once (1xCircuit HIIT ) or twice (2xCircuit HIIT ) daily for 4 weeks. In this single-center, two-arm randomized, controlled study, 24 men and women (age: 25 ± 5 years) first received no training instructions for 4 weeks and then performed 4 weeks of either 1xCircuit HIIT or 2xCircuit HIIT (5 men and 7 women in each group) daily. The 1xCircuit HIIT and 2xCircuit HIIT participants carried out 90.7 and 85.7% of all planned training sessions, respectively, with average heart rates during the 6-min sessions of 74.3 and 70.8% of maximal heart rate. Body, fat and fat-free mass, and metabolic rate at rest did not differ between the groups or between time-points of measurement. Heart rate while running at 6 km⋅h -1 declined after the intervention in both groups. Submaximal and peak oxygen uptake, the respiratory exchange ratio and heart rate recovery were not altered by either intervention. The maximal numbers of push-ups, leg-levers, burpees, 45°-one-legged squats and 30-s skipping, as well as perception of general health improved in both groups. Our 1xCircuit HIIT or 2xCircuit HIIT interventions improved certain parameters of functional strength and certain dimensions of quality of life in young untrained individuals. However, they were not sufficient to enhance cardio-respiratory fitness, in particular peak oxygen uptake.

  4. [Spectral analysis of Heart Rate Variability in psychiatric patients: autonomic nervous system evaluation in psychotic, anxiety and depressive disorders].

    PubMed

    Lo Turco, Giovanni; Grimaldi Di Terresena, Liria

    2012-01-01

    The aim of this study was to test the primary hypothesis of altered Heart Rate Variability (HRV) and heart rate in a sample of patients with mental disorders and the secondary hypothesis of normalization of HRV values as a result of clinical improvement. The study was conducted on a sample of 90 patients with psychotic, anxiety and mood disorders. Each patient was subjected to detection of HRV and heart rate via a photoplethysmographic sensor and evaluated with rating scales based on the specific disorder. The parameters detected in the sample were compared with a control group of healthy subjects. There were no significant differences of cardiac autonomic modulation between the group of patients in whom is possible exclude the drug influence and the control group; significantly lower values of HRV parameters in the group of patients with drug influence, and especially in subgroup of psychotic patients, compared to controls, are, instead, detected. The study also shows a significant increase in heart rate as a common feature in mental disorders, regardless of treatment. Clinical improvement appears to promote the normalization of the variability in patients with high DS of tachogram. The study suggests a potential increased risk of cardiovascular mortality in patients, as evidenced by the increased values of heart rate, regardless of drug treatment. This risk is even more pronounced in psychotic patients in drug treatment because of the simultaneous significant reduction of HRV parameters.

  5. BIOPHYSICAL CHARACTERISATION OF THE UNDER-APPRECIATED AND IMPORTANT RELATIONSHIP BETWEEN HEART RATE VARIABILITY AND HEART RATE

    PubMed Central

    Monfredi, Oliver; Lyashkov, Alexey E; Johnsen, Anne-Berit; Inada, Shin; Schneider, Heiko; Wang, Ruoxi; Nirmalan, Mahesh; Wisloff, Ulrik; Maltsev, Victor A; Lakatta, Edward G; Zhang, Henggui; Boyett, Mark R

    2014-01-01

    Heart rate variability (beat-to-beat changes in the RR interval) has attracted considerable attention over the last 30+ years (PubMed currently lists >17,000 publications). Clinically, a decrease in heart rate variability is correlated to higher morbidity and mortality in diverse conditions, from heart disease to foetal distress. It is usually attributed to fluctuation in cardiac autonomic nerve activity. We calculated heart rate variability parameters from a variety of cardiac preparations (including humans, living animals, Langendorff-perfused heart and single sinoatrial nodal cell) in diverse species, combining this with data from previously published papers. We show that regardless of conditions, there is a universal exponential decay-like relationship between heart rate variability and heart rate. Using two biophysical models, we develop a theory for this, and confirm that heart rate variability is primarily dependent on heart rate and cannot be used in any simple way to assess autonomic nerve activity to the heart. We suggest that the correlation between a change in heart rate variability and altered morbidity and mortality is substantially attributable to the concurrent change in heart rate. This calls for re-evaluation of the findings from many papers that have not adjusted properly or at all for heart rate differences when comparing heart rate variability in multiple circumstances. PMID:25225208

  6. Initial fractal exponent of heart-rate variability is associated with success of early resuscitation in patients with severe sepsis or septic shock: a prospective cohort study

    PubMed Central

    Brown, Samuel M.; Tate, Quinn; Jones, Jason P.; Knox, Daniel; Kuttler, Kathryn G.; Lanspa, Michael; Rondina, Matthew T.; Grissom, Colin K.; Behera, Subhasis; Mathews, V.J.; Morris, Alan

    2013-01-01

    Introduction Heart-rate variability reflects autonomic nervous system tone as well as the overall health of the baroreflex system. We hypothesized that loss of complexity in heart-rate variability upon ICU admission would be associated with unsuccessful early resuscitation of sepsis. Methods We prospectively enrolled patients admitted to ICUs with severe sepsis or septic shock from 2009 to 2011. We studied 30 minutes of EKG, sampled at 500 Hz, at ICU admission and calculated heart-rate complexity via detrended fluctuation analysis. Primary outcome was vasopressor independence at 24 hours after ICU admission. Secondary outcome was 28-day mortality. Results We studied 48 patients, of whom 60% were vasopressor independent at 24 hours. Five (10%) died within 28 days. The ratio of fractal alpha parameters was associated with both vasopressor independence and 28-day mortality (p=0.04) after controlling for mean heart rate. In the optimal model, SOFA score and the long-term fractal alpha parameter were associated with vasopressor independence. Conclusions Loss of complexity in heart rate variability is associated with worse outcome early in severe sepsis and septic shock. Further work should evaluate whether complexity of heart rate variability (HRV) could guide treatment in sepsis. PMID:23958243

  7. Simultaneous multi-depth assessment of tissue oxygen saturation in thenar and forearm using near-infrared spectroscopy during a simple cardiovascular challenge

    PubMed Central

    2009-01-01

    Introduction Hypovolemia and hypovolemic shock are life-threatening conditions that occur in numerous clinical scenarios. Near-infrared spectroscopy (NIRS) has been widely explored, successfully and unsuccessfully, in an attempt to use it as an early detector of hypovolemia by measuring tissue oxygen saturation (StO2). In order to investigate the measurement site dependence and probe dependence of NIRS in response to hemodynamic changes, such as hypovolemia, we applied a simple cardiovascular challenge: a posture change from supine to upright, causing a decrease in stroke volume (as in hypovolemia) and a heart rate increase in combination with peripheral vasoconstriction to maintain adequate blood pressure. Methods Multi-depth NIRS was used in nine healthy volunteers to assess changes in StO2 in the thenar and forearm in response to the hemodynamic changes associated with a posture change from supine to upright. Results A posture change from supine to upright resulted in a significant increase (P < 0.001) in heart rate. Thenar StO2 did not respond to the hemodynamic changes following the posture change, whereas forearm StO2 did. Forearm StO2 was significantly lower (P < 0.001) in the upright position compared to supine for all probing depths. Conclusions The primary findings in this study were that forearm StO2 is a more sensitive parameter to hemodynamic changes than thenar StO2 and that the depth at which StO2 is measured is of minor influence. Our data support the use of forearm StO2 as a sensitive parameter for the detection of central hypovolemia and hypovolemic shock in (trauma) patients. PMID:19951389

  8. Comparison of heart rate variability and pulse rate variability detected with photoplethysmography

    NASA Astrophysics Data System (ADS)

    Rauh, Robert; Limley, Robert; Bauer, Rainer-Dieter; Radespiel-Troger, Martin; Mueck-Weymann, Michael

    2004-08-01

    This study compares ear photoplethysmography (PPG) and electrocardiogram (ECG) in providing accurate heart beat intervals for use in calculations of heart rate variability (HRV, from ECG) or of pulse rate variability (PRV, from PPG) respectively. Simultaneous measurements were taken from 44 healthy subjects at rest during spontaneous breathing and during forced metronomic breathing (6/min). Under both conditions, highly significant (p > 0.001) correlations (1.0 > r > 0.97) were found between all evaluated common HRV and PRV parameters. However, under both conditions the PRV parameters were higher than HRV. In addition, we calculated the limits of agreement according to Bland and Altman between both techniques and found good agreement (< 10% difference) for heart rate and standard deviation of normal-to-normal intervals (SDNN), but only moderate (10-20%) or even insufficient (> 20%) agreement for other standard HRV and PRV parameters. Thus, PRV data seem to be acceptable for screening purposes but, at least at this state of knowledge, not for medical decision making. However, further studies are needed before more certain determination can be made.

  9. Heart Rate and Heart Rate Variability in Dairy Cows with Different Temperament and Behavioural Reactivity to Humans

    PubMed Central

    Tőzsér, János; Szenci, Ottó; Póti, Péter; Pajor, Ferenc

    2015-01-01

    From the 1990s, extensive research was started on the physiological aspects of individual traits in animals. Previous research has established two extreme (proactive and reactive) coping styles in several animal species, but the means of reactivity with the autonomic nervous system (ANS) activity has not yet been investigated in cattle. The aim of this study was the characterization of cardiac autonomic activity under different conditions in cows with different individual characteristics. For this purpose, we investigated heart rate and ANS-related heart rate variability (HRV) parameters of dairy cows (N = 282) on smaller- and larger-scale farms grouped by (1) temperament and (2) behavioural reactivity to humans (BRH). Animals with high BRH scores were defined as impulsive, while animals with low BRH scores were defined as reserved. Cardiac parameters were calculated for undisturbed lying (baseline) and for milking bouts, the latter with the presence of an unfamiliar person (stressful situation). Sympathetic tone was higher, while vagal activity was lower in temperamental cows than in calm animals during rest both on smaller- and larger-scale farms. During milking, HRV parameters were indicative of a higher sympathetic and a lower vagal activity of temperamental cows as compared to calm ones in farms of both sizes. Basal heart rate did not differ between BRH groups either on smaller- or larger-scale farms. Differences between basal ANS activity of impulsive and reserved cows reflected a higher resting vagal and lower sympathetic activity of reserved animals compared to impulsive ones both on smaller- and larger-scale farms. There was no difference either in heart rate or in HRV parameters between groups during milking neither in smaller- nor in larger-scale farms. These two groupings allowed to draw possible parallels between personality and cardiac autonomic activity during both rest and milking in dairy cows. Heart rate and HRV seem to be useful for characterisation of physiological differences related to temperament and BRH. PMID:26291979

  10. Sensing Disaster: The Use of Wearable Sensor Technology to Decrease Firefighter Line-of-Duty Deaths

    DTIC Science & Technology

    2015-12-01

    peripheral oxygen or SpO2), and temperature , to name but a few.164 The current GTWM allows these sensors to be plugged in anywhere on the shirt, although...desired monitoring parameters included the “heart rate, respiratory rate, body temperature , blood oxygen saturation levels, environmental...physiological tests and parameters of firefighters that should be monitored are the EKG, heart rate (HR), body temperature , blood oxygen saturation

  11. Heart rate turbulence after ventricular premature beats in healthy Doberman pinschers and those with dilated cardiomyopathy.

    PubMed

    Harris, J D; Little, C J L; Dennis, J M; Patteson, M W

    2017-10-01

    To describe the measurement of heart rate turbulence (HRT) after ventricular premature beats and compare HRT in healthy Doberman pinschers and those with dilated cardiomyopathy (DCM), with and without congestive heart failure (CHF). Sixty-five client-owned Dobermans: 20 healthy (NORMAL), 31 with preclinical DCM and 14 with DCM and CHF (DCM + CHF). A retrospective study of data retrieved from clinical records and ambulatory ECG (Holter) archives, including data collected previously for a large-scale prospective study of Dobermans with preclinical DCM. Holter data were reanalysed quantitatively, including conventional time-domain heart rate variability and the HRT parameters turbulence onset and turbulence slope. Heart rate turbulence could be measured in 58/65 dogs. Six Holter recordings had inadequate ventricular premature contractions (VPCs) and one exhibited VPCs too similar to sinus morphology. Heart rate turbulence parameter, turbulence onset, was significantly reduced in DCM dogs, whereas conventional heart rate variability measures were not. Heart rate variability and HRT markers were reduced in DCM + CHF dogs as expected. Heart rate turbulence can be measured from the majority of good quality standard canine 24-hour Holter recordings with >5 VPCs. Turbulence onset is significantly reduced in Dobermans with preclinical DCM which indicates vagal withdrawal early in the course of disease. Heart rate turbulence is a powerful prognostic indicator in human cardiac disease which can be measured from standard 24-hour ambulatory ECG (Holter) recordings using appropriate computer software. Further studies are warranted to assess whether HRT may be of prognostic value in dogs with preclinical DCM and in other canine cardiac disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Reliability and concurrent validity of a peripheral pulse oximeter and health-app system for the quantification of heart rate in healthy adults.

    PubMed

    Losa-Iglesias, Marta Elena; Becerro-de-Bengoa-Vallejo, Ricardo; Becerro-de-Bengoa-Losa, Klark Ricardo

    2016-06-01

    There are downloadable applications (Apps) for cell phones that can measure heart rate in a simple and painless manner. The aim of this study was to assess the reliability of this type of App for a Smartphone using an Android system, compared to the radial pulse and a portable pulse oximeter. We performed a pilot observational study of diagnostic accuracy, randomized in 46 healthy volunteers. The patients' demographic data and cardiac pulse were collected. Radial pulse was measured by palpation of the radial artery with three fingers at the wrist over the radius; a low-cost portable, liquid crystal display finger pulse oximeter; and a Heart Rate Plus for Samsung Galaxy Note®. This study demonstrated high reliability and consistency between systems with respect to the heart rate parameter of healthy adults using three systems. For all parameters, ICC was > 0.93, indicating excellent reliability. Moreover, CVME values for all parameters were between 1.66-4.06 %. We found significant correlation coefficients and no systematic differences between radial pulse palpation and pulse oximeter and a high precision. Low-cost pulse oximeter and App systems can serve as valid instruments for the assessment of heart rate in healthy adults. © The Author(s) 2014.

  13. The predictive value of resting heart rate following osmotherapy in brain injury: back to basics

    PubMed Central

    2012-01-01

    Background The importance of resting heart rate as a prognostic factor was described in several studies. An elevated heart rate is an independent risk factor for adverse cardiovascular events and total mortality in patients with coronary artery disease, chronic heart failure, and the general population. Also heart rate is elevated in the Multi Organ Dysfunction Syndrome (MODS) and the mortality due to MODS is highly correlated with inadequate sinus tachycardia. To evaluate the value of resting heart rate in predicting mortality in patients with traumatic brain injury along scoring systems like Acute Physiology and Chronic Health Evaluation(APACHE II), Sequential Organ Failure Assessment (SOFA) and Glasgow Coma Score (GCS). Method By analyzing data which was collected from an open labeled randomized clinical trial that compared the different means of osmotherapy (mannitol vs bolus or infusion hypertonic saline), heart rate, GCS, APACHE II and SOFA score were measured at baseline and daily for 7 days up to 60 days and the relationship between elevated heart rate and mortality during the first 7 days and 60th day were assessed. Results After adjustments for confounding factors, although there was no difference in mean heart rate between either groups of alive and expired patients, however, we have found a relative correlation between 60th day mortality rate and resting heart rate (P=0.07). Conclusion Heart rate can be a prognostic factor for estimating mortality rate in brain injury patients along with APACHE II and SOFA scores in patients with brain injury. PMID:23351393

  14. Myocardial Infarction Injury in Patients with Chronic Lung Disease Entering Pulmonary Rehabilitation: Frequency and Association with Heart Rate Parameters.

    PubMed

    Sima, Carmen A; Lau, Benny C; Taylor, Carolyn M; van Eeden, Stephan F; Reid, W Darlene; Sheel, Andrew W; Kirkham, Ashley R; Camp, Pat G

    2018-03-14

    Myocardial infarction (MI) remains under-recognized in chronic lung disease (CLD) patients. Rehabilitation health professionals need accessible clinical measurements to identify the presence of prior MI in order to determine appropriate training prescription. To estimate prior MI in CLD patients entering a pulmonary rehabilitation program, as well as its association with heart rate parameters such as resting heart rate and chronotropic response index. Retrospective cohort design. Pulmonary rehabilitation outpatient clinic in a tertiary care university-affiliated hospital. Eighty-five CLD patients were studied. Electrocardiograms at rest and peak cardiopulmonary exercise testing, performed before pulmonary rehabilitation, were analyzed. Electrocardiographic evidence of prior MI, quantified by the Cardiac Infarction Injury Score (CIIS), was contrasted with reported myocardial events and then correlated with resting heart rate and chronotropic response index parameters. CIIS, resting heart rate, and chronotropic response index. Sixteen CLD patients (19%) demonstrated electrocardiographic evidence of prior MI, but less than half (8%) had a reported MI history (P < .05). The Cohen's kappa test revealed poor level of agreement between CIIS and medical records (kappa = 0.165), indicating that prior MI diagnosis was under-reported in the medical records. Simple and multiple regression analyses showed that resting heart rate but not chronotropic response index was positively associated with CIIS in our population (R 2 = 0.29, P < .001). CLD patients with a resting heart rate higher than 80 beats/min had approximately 5 times higher odds of having prior MI, as evidenced by a CIIS ≥20. CLD patients entering pulmonary rehabilitation are at risk of unreported prior MI. Elevated resting heart rate seems to be an indicator of prior MI in CLD patients; therefore, careful adjustment of training intensity such as intermittent training is recommended under these circumstances. III. Copyright © 2018 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  15. Research on human physiological parameters intelligent clothing based on distributed Fiber Bragg Grating

    NASA Astrophysics Data System (ADS)

    Miao, Changyun; Shi, Boya; Li, Hongqiang

    2008-12-01

    A human physiological parameters intelligent clothing is researched with FBG sensor technology. In this paper, the principles and methods of measuring human physiological parameters including body temperature and heart rate in intelligent clothing with distributed FBG are studied, the mathematical models of human physiological parameters measurement are built; the processing method of body temperature and heart rate detection signals is presented; human physiological parameters detection module is designed, the interference signals are filtered out, and the measurement accuracy is improved; the integration of the intelligent clothing is given. The intelligent clothing can implement real-time measurement, processing, storage and output of body temperature and heart rate. It has accurate measurement, portability, low cost, real-time monitoring, and other advantages. The intelligent clothing can realize the non-contact monitoring between doctors and patients, timely find the diseases such as cancer and infectious diseases, and make patients get timely treatment. It has great significance and value for ensuring the health of the elders and the children with language dysfunction.

  16. [Multi-month dynamics of the functional condition of organism of normal male northeners of Russia].

    PubMed

    Solonin, Iu G; Markov, A L; Boĭko, E R

    2012-01-01

    In conjunction with the Mars-500 project, 17 male residents (25-46 y.o.) of the North of Russia (62 degrees 40'N) were examined monthly using hard- and software EKOSAN-2007. In the period of June, 2010 through to November, 2011 they visited a standard laboratory to go through comprehensive anthropophysiometric, psychophysiological and physiological investigations at rest and combined with exercise, standing and cold tests aimed at tracking the seasonal responses of the body functional parameters. The larger part of group-average psychomotor, breathing and circulation measurements as well as heart rate variability did not exhibit statistically significant differences between months or seasons. Reliable seasonal variations were documented in the life index, body and cutaneous temperature, myocardium index and regulatory systems activity. A correlation between environmental and some body functional parameters was established. In the course of the multi-month monitoring there were periods when essentially healthy people were diagnosed as prenosologic and even premorbid. Some findings in the functioning of male northerner's organism are clearly attributable to living in the high-altitude area.

  17. Wearable vital parameters monitoring system

    NASA Astrophysics Data System (ADS)

    Caramaliu, Radu Vadim; Vasile, Alexandru; Bacis, Irina

    2015-02-01

    The system we propose monitors body temperature, heart rate and beside this, it tracks if the person who wears it suffers a faint. It uses a digital temperature sensor, a pulse sensor and a gravitational acceleration sensor to monitor the eventual faint or small heights free falls. The system continuously tracks the GPS position when available and stores the last valid data. So, when measuring abnormal vital parameters the module will send an SMS, using the GSM cellular network , with the person's social security number, the last valid GPS position for that person, the heart rate, the body temperature and, where applicable, a valid fall alert or non-valid fall alert. Even though such systems exist, they contain only faint detection or heart rate detection. Usually there is a strong correlation between low/high heart rate and an eventual faint. Combining both features into one system results in a more reliable detection device.

  18. Management of heart failure in the new era: the role of scores.

    PubMed

    Mantegazza, Valentina; Badagliacca, Roberto; Nodari, Savina; Parati, Gianfranco; Lombardi, Carolina; Di Somma, Salvatore; Carluccio, Erberto; Dini, Frank Lloyd; Correale, Michele; Magrì, Damiano; Agostoni, Piergiuseppe

    2016-08-01

    Heart failure is a widespread syndrome involving several organs, still characterized by high mortality and morbidity, and whose clinical course is heterogeneous and hardly predictable.In this scenario, the assessment of heart failure prognosis represents a fundamental step in clinical practice. A single parameter is always unable to provide a very precise prognosis. Therefore, risk scores based on multiple parameters have been introduced, but their clinical utility is still modest. In this review, we evaluated several prognostic models for acute, right, chronic, and end-stage heart failure based on multiple parameters. In particular, for chronic heart failure we considered risk scores essentially based on clinical evaluation, comorbidities analysis, baroreflex sensitivity, heart rate variability, sleep disorders, laboratory tests, echocardiographic imaging, and cardiopulmonary exercise test parameters. What is at present established is that a single parameter is not sufficient for an accurate prediction of prognosis in heart failure because of the complex nature of the disease. However, none of the scoring systems available is widely used, being in some cases complex, not user-friendly, or based on expensive or not easily available parameters. We believe that multiparametric scores for risk assessment in heart failure are promising but their widespread use needs to be experienced.

  19. The influence of betamethasone on fetal heart rate variability, obtained by non-invasive fetal electrocardiogram recordings.

    PubMed

    Verdurmen, Kim M J; Warmerdam, Guy J J; Lempersz, Carlijn; Hulsenboom, Alexandra D J; Renckens, Joris; Dieleman, Jeanne P; Vullings, Rik; van Laar, Judith O E H; Oei, S Guid

    2018-04-01

    Betamethasone is widely used to enhance fetal lung maturation in case of threatened preterm labour. Fetal heart rate variability is one of the most important parameters to assess in fetal monitoring, since it is a reliable indicator for fetal distress. To describe the effect of betamethasone on fetal heart rate variability, by applying spectral analysis on non-invasive fetal electrocardiogram recordings. Prospective cohort study. Patients that require betamethasone, with a gestational age from 24 weeks onwards. Fetal heart rate variability parameters on day 1, 2, and 3 after betamethasone administration are compared to a reference measurement. Following 68 inclusions, 12 patients remained with complete series of measurements and sufficient data quality. During day 1, an increase in absolute fetal heart rate variability values was seen. During day 2, a decrease in these values was seen. All trends indicate to return to pre-medication values on day 3. Normalised high- and low-frequency power show little changes during the study period. The changes in fetal heart rate variability following betamethasone administration show the same pattern when calculated by spectral analysis of the fetal electrocardiogram, as when calculated by cardiotocography. Since normalised spectral values show little changes, the influence of autonomic modulation seems minor. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. A Multi-Route Model of Nicotine-Cotinine Pharmacokinetics, Pharmacodynamics and Brain Nicotinic Acetylcholine Receptor Binding in Humans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Teeguarden, Justin G.; Housand, Conrad; Smith, Jordan N.

    The pharmacokinetics of nicotine, the pharmacologically active alkaloid in tobacco responsible for addiction, are well characterized in humans. We developed a physiologically based pharmacokinetic/pharmacodynamic model of nicotine pharmacokinetics, brain dosimetry and brain nicotinic acetylcholine receptor (nAChRs) occupancy. A Bayesian framework was applied to optimize model parameters against multiple human data sets. The resulting model was consistent with both calibration and test data sets, but in general underestimated variability. A pharmacodynamic model relating nicotine levels to increases in heart rate as a proxy for the pharmacological effects of nicotine accurately described the nicotine related changes in heart rate and the developmentmore » and decay of tolerance to nicotine. The PBPK model was utilized to quantitatively capture the combined impact of variation in physiological and metabolic parameters, nicotine availability and smoking compensation on the change in number of cigarettes smoked and toxicant exposure in a population of 10,000 people presented with a reduced toxicant (50%), reduced nicotine (50%) cigarette Across the population, toxicant exposure is reduced in some but not all smokers. Reductions are not in proportion to reductions in toxicant yields, largely due to partial compensation in response to reduced nicotine yields. This framework can be used as a key element of a dosimetry-driven risk assessment strategy for cigarette smoke constituents.« less

  1. Short-term heart rate variability in dogs with sick sinus syndrome or chronic mitral valve disease as compared to healthy controls.

    PubMed

    Bogucki, Sz; Noszczyk-Nowak, A

    2017-03-28

    Heart rate variability is an established risk factor for mortality in both healthy dogs and animals with heart failure. The aim of this study was to compare short-term heart rate variability (ST-HRV) parameters from 60-min electrocardiograms in dogs with sick sinus syndrome (SSS, n=20) or chronic mitral valve disease (CMVD, n=20) and healthy controls (n=50), and to verify the clinical application of ST-HRV analysis. The study groups differed significantly in terms of both time - and frequency- domain ST-HRV parameters. In the case of dogs with SSS and healthy controls, particularly evident differences pertained to HRV parameters linked directly to the variability of R-R intervals. Lower values of standard deviation of all R-R intervals (SDNN), standard deviation of the averaged R-R intervals for all 5-min segments (SDANN), mean of the standard deviations of all R-R intervals for all 5-min segments (SDNNI) and percentage of successive R-R intervals >50 ms (pNN50) corresponded to a decrease in parasympathetic regulation of heart rate in dogs with CMVD. These findings imply that ST-HRV may be useful for the identification of dogs with SSS and for detection of dysautonomia in animals with CMVD.

  2. [Heart Rate Variability as an Indicator of Mental Stress in Surgeons - A Review of the Literature].

    PubMed

    Thielmann, B; Boeckelmann, I

    2016-10-01

    The risk assessment of mental stress and early detection of mental illness among surgeons are much debated issues, because the perceived working conditions are important for their own health and that of the patients. Studies of predominantly mental stress are increasing and stay up-to-date. The psychological strain of surgeons is generally regarded as high. In order to objectively determine stress, the heart rate and its variability have been established as parameters. Based on the physiological stress parameter, it is possible to determine the previous level of strain. This work presents a summary of recent scientific studies to explore the stress in operative surgeons on the basis of the physiological stress parameters heart rate (HR) and heart rate variability (HRV). A PubMed search until spring of 2014 was performed. A total of 10 studies were included which deal with the mental stress and strain analysis by surgeons. In this case, 4 studies used only the HR and the further 6 studies used the HRV as a stress parameter. First stress and strain analyses of surgeons have been around since the early 1980s. The studies were usually carried out solely within the sample examined. Control groups have rarely or not been studied. In summary, stressed surgeons offered a higher intraoperative heart rate and a low expression of the HRV. The same was experienced in operating surgeons compared to the assistant surgeons or with inexperienced operating surgeons compared to experienced surgeons. Georg Thieme Verlag KG Stuttgart · New York.

  3. Assessing effects of BL67 points stimulation on fetal heart rate parameters and fetal movements during nonstress test.

    PubMed

    Pirhadi, Masume; Valiani, Mahboube

    2017-01-01

    One of the main goals of antenatal testing is to identify fetuses at the risk of neurologic injury or death so that these adverse outcomes can be prevented. We want to assess the effects of BL67 points' stimulation on fetal heart rate parameters and fetal movements during nonstress test (NST). We did a quasi-experimental design in Shahid Beheshti Hospital in Isfahan in 2011. This study aims to assessment of the effects of BL67 points' stimulation on fetal heart rate parameters and fetal movements. We did a randomized controlled clinical trial in Shahid Beheshti Hospital in Isfahan in 2011. This study is a quasi-experimental design that was conducted in one group and the two steps (before-after study). Participants were pregnant women (primigravida) who were 35-18 years that refer to Shahid Beheshti Hospital in Isfahan in 2011 to receive routine prenatal care. The 32 pregnant women were selected for acupressure during the second NST. The statistical processing was performed by descriptive, paired t -test through SPSS version 20. There was no significant difference in mean number of accelerations in fetal heart rate and mean number of fetal movement before and after intervention; however, there was a significant difference in mean time to the second acceleration before and after the intervention ( P = 0.04). No difference between parameters of the fetal heart rate before and after stimulation and lack of uterine response by this method is a significant advantage and is probably why stimulating this point could not create a risk to the fetuses.

  4. Paroxysmal atrial fibrillation prediction based on HRV analysis and non-dominated sorting genetic algorithm III.

    PubMed

    Boon, K H; Khalil-Hani, M; Malarvili, M B

    2018-01-01

    This paper presents a method that able to predict the paroxysmal atrial fibrillation (PAF). The method uses shorter heart rate variability (HRV) signals when compared to existing methods, and achieves good prediction accuracy. PAF is a common cardiac arrhythmia that increases the health risk of a patient, and the development of an accurate predictor of the onset of PAF is clinical important because it increases the possibility to electrically stabilize and prevent the onset of atrial arrhythmias with different pacing techniques. We propose a multi-objective optimization algorithm based on the non-dominated sorting genetic algorithm III for optimizing the baseline PAF prediction system, that consists of the stages of pre-processing, HRV feature extraction, and support vector machine (SVM) model. The pre-processing stage comprises of heart rate correction, interpolation, and signal detrending. After that, time-domain, frequency-domain, non-linear HRV features are extracted from the pre-processed data in feature extraction stage. Then, these features are used as input to the SVM for predicting the PAF event. The proposed optimization algorithm is used to optimize the parameters and settings of various HRV feature extraction algorithms, select the best feature subsets, and tune the SVM parameters simultaneously for maximum prediction performance. The proposed method achieves an accuracy rate of 87.7%, which significantly outperforms most of the previous works. This accuracy rate is achieved even with the HRV signal length being reduced from the typical 30 min to just 5 min (a reduction of 83%). Furthermore, another significant result is the sensitivity rate, which is considered more important that other performance metrics in this paper, can be improved with the trade-off of lower specificity. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. [Multi-channel data collection and visualization system for intramyocardial electrograms].

    PubMed

    Kastner, P; Wimmer, W; Hutten, H

    2000-11-01

    The aim of the project was to develop a multichannel data acquisition system for the recording and visualisation of intramyocardial electrograms (IEGM) from both the spontaneously beating and the artificially paced heart. Signal processing comprises multi-step amplification, filtering (0.05-800 Hz), and AD conversion (12 Bit max. 6.25 kHz). IEGMs can be obtained either in unipolar or bipolar mode. Stimulation of the heart is achieved by an incorporated programmable dual-chamber pacemaker that can be selectively switched to the input channels. A LabView-based graphical user interface permits the programming of all system parameters via a microcontroller, and supports data acquisition and visualisation. The system can be used in animal experiments to monitor the spread of excitation across the heart, to measure propagation velocity, or to measure the impact of drugs and pathological changes on the morphology of IEGMs.

  6. Effects of far infrared rays irradiated from ceramic material (BIOCERAMIC) on psychological stress-conditioned elevated heart rate, blood pressure, and oxidative stress-suppressed cardiac contractility.

    PubMed

    Leung, Ting-Kai; Chen, Chien-Ho; Tsai, Shih-Ying; Hsiao, George; Lee, Chi-Ming

    2012-10-31

    The present study examined the effects of BIOCERAMIC on psychological stress-conditioned elevated heart rate, blood pressure and oxidative stress-suppressed cardiac contractility using in vivo and in vitro animal models. We investigated the effects of BIOCERAMIC on the in vivo cardiovascular hemodynamic parameters of rats by monitoring their heart rates, systolic blood pressure, mean blood pressure and diastolic blood pressure. Thereafter, we assayed its effects on the heart rate in an isolated frog heart with and without adrenaline stimulation, and on cardiac contractility under oxidative stress. BIOCERAMIC caused significant decreases in heart rates and systolic and mean blood pressure in the stress-conditioned heart rate rat models (P < 0.05), as well as in the experimental models of an isolated frog heart with and without adrenaline stimulation (P < 0.05), and normalized cardiac contractility under oxidative stress (P < 0.05). BIOCERAMIC may, therefore, normalize the effects of psychological stress and oxidative stress conditions.

  7. Disease management: remote monitoring in heart failure patients with implantable defibrillators, resynchronization devices, and haemodynamic monitors.

    PubMed

    Abraham, William T

    2013-06-01

    Heart failure represents a major public health concern, associated with high rates of morbidity and mortality. A particular focus of contemporary heart failure management is reduction of hospital admission and readmission rates. While optimal medical therapy favourably impacts the natural history of the disease, devices such as cardiac resynchronization therapy devices and implantable cardioverter defibrillators have added incremental value in improving heart failure outcomes. These devices also enable remote patient monitoring via device-based diagnostics. Device-based measurement of physiological parameters, such as intrathoracic impedance and heart rate variability, provide a means to assess risk of worsening heart failure and the possibility of future hospitalization. Beyond this capability, implantable haemodynamic monitors have the potential to direct day-to-day management of heart failure patients to significantly reduce hospitalization rates. The use of a pulmonary artery pressure measurement system has been shown to significantly reduce the risk of heart failure hospitalization in a large randomized controlled study, the CardioMEMS Heart Sensor Allows Monitoring of Pressure to Improve Outcomes in NYHA Class III Heart Failure Patients (CHAMPION) trial. Observations from a pilot study also support the potential use of a left atrial pressure monitoring system and physician-directed patient self-management paradigm; these observations are under further investigation in the ongoing LAPTOP-HF trial. All these devices depend upon high-intensity remote monitoring for successful detection of parameter deviations and for directing and following therapy.

  8. Influence of geomagnetic activity and earth weather changes on heart rate and blood pressure in young and healthy population

    NASA Astrophysics Data System (ADS)

    Ozheredov, V. A.; Chibisov, S. M.; Blagonravov, M. L.; Khodorovich, N. A.; Demurov, E. A.; Goryachev, V. A.; Kharlitskaya, E. V.; Eremina, I. S.; Meladze, Z. A.

    2017-05-01

    There are many references in the literature related to connection between the space weather and the state of human organism. The search of external factors influence on humans is a multi-factor problem and it is well known that humans have a meteo-sensitivity. A direct problem of finding the earth weather conditions, under which the space weather manifests itself most strongly, is discussed in the present work for the first time in the helio-biology. From a formal point of view, this problem requires identification of subset (magnetobiotropic region) in three-dimensional earth's weather parameters such as pressure, temperature, and humidity, corresponding to the days when the human body is the most sensitive to changes in the geomagnetic field variations and when it reacts by statistically significant increase (or decrease) of a particular physiological parameter. This formulation defines the optimization of the problem, and the solution of the latter is not possible without the involvement of powerful metaheuristic methods of searching. Using the algorithm of differential evolution, we prove the existence of magnetobiotropic regions in the earth's weather parameters, which exhibit magneto-sensitivity of systolic, diastolic blood pressure, and heart rate of healthy young subjects for three weather areas (combinations of atmospheric temperature, pressure, and humidity). The maximum value of the correlation confidence for the measurements attributable to the days of the weather conditions that fall into each of three magnetobiotropic areas is an order of 0.006, that is almost 10 times less than the confidence, equal to 0.05, accepted in many helio-biological researches.

  9. Influence of geomagnetic activity and earth weather changes on heart rate and blood pressure in young and healthy population.

    PubMed

    Ozheredov, V A; Chibisov, S M; Blagonravov, M L; Khodorovich, N A; Demurov, E A; Goryachev, V A; Kharlitskaya, E V; Eremina, I S; Meladze, Z A

    2017-05-01

    There are many references in the literature related to connection between the space weather and the state of human organism. The search of external factors influence on humans is a multi-factor problem and it is well known that humans have a meteo-sensitivity. A direct problem of finding the earth weather conditions, under which the space weather manifests itself most strongly, is discussed in the present work for the first time in the helio-biology. From a formal point of view, this problem requires identification of subset (magnetobiotropic region) in three-dimensional earth's weather parameters such as pressure, temperature, and humidity, corresponding to the days when the human body is the most sensitive to changes in the geomagnetic field variations and when it reacts by statistically significant increase (or decrease) of a particular physiological parameter. This formulation defines the optimization of the problem, and the solution of the latter is not possible without the involvement of powerful metaheuristic methods of searching. Using the algorithm of differential evolution, we prove the existence of magnetobiotropic regions in the earth's weather parameters, which exhibit magneto-sensitivity of systolic, diastolic blood pressure, and heart rate of healthy young subjects for three weather areas (combinations of atmospheric temperature, pressure, and humidity). The maximum value of the correlation confidence for the measurements attributable to the days of the weather conditions that fall into each of three magnetobiotropic areas is an order of 0.006, that is almost 10 times less than the confidence, equal to 0.05, accepted in many helio-biological researches.

  10. [Crataegus Special Extract WS 1442 in NYHA II heart failure. A placebo controlled randomized double-blind study].

    PubMed

    Leuchtgens, H

    1993-07-20

    In 30 patients with stage NYHA II cardiac insufficiency, a placebo-controlled randomized double-blind study was carried out to determine the efficacy of the Crataegus special extract WS 1442. Treatment duration was 8 weeks, and the substance was administered at a dose of 1 capsule taken twice a day. The main target parameters were alteration in the pressure-x-rate product (PRP) under standardised loading on a bicycle ergometer, and a score of subjective improvement of complaints elicited by a questionnaire. Secondary parameters were exercise tolerance and the change in heart rate and arterial blood pressure. The active substance group showed a statistically significant advantage over placebo in terms of changes in PRP (at a load of 50 W) and the score, but also in the secondary parameter heart rate. In both groups, systolic and diastolic blood pressure was mildly reduced. No adverse reactions occurred.

  11. A novel method for pediatric heart sound segmentation without using the ECG.

    PubMed

    Sepehri, Amir A; Gharehbaghi, Arash; Dutoit, Thierry; Kocharian, Armen; Kiani, A

    2010-07-01

    In this paper, we propose a novel method for pediatric heart sounds segmentation by paying special attention to the physiological effects of respiration on pediatric heart sounds. The segmentation is accomplished in three steps. First, the envelope of a heart sounds signal is obtained with emphasis on the first heart sound (S(1)) and the second heart sound (S(2)) by using short time spectral energy and autoregressive (AR) parameters of the signal. Then, the basic heart sounds are extracted taking into account the repetitive and spectral characteristics of S(1) and S(2) sounds by using a Multi-Layer Perceptron (MLP) neural network classifier. In the final step, by considering the diastolic and systolic intervals variations due to the effect of a child's respiration, a complete and precise heart sounds end-pointing and segmentation is achieved. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.

  12. Prognostic capacity of a clinically indicated exercise test for cardiovascular mortality is enhanced by combined analysis of exercise capacity, heart rate recovery and T-wave alternans.

    PubMed

    Minkkinen, Mikko; Nieminen, Tuomo; Verrier, Richard L; Leino, Johanna; Lehtimäki, Terho; Viik, Jari; Lehtinen, Rami; Nikus, Kjell; Kööbi, Tiit; Turjanmaa, Väinö; Kähönen, Mika

    2015-09-01

    Exercise capacity, heart rate recovery and T-wave alternans are independent predictors of cardiovascular mortality. We tested whether these parameters contain supplementary prognostic information. A total of 3609 consecutive patients (2157 men) referred for a routine, clinically indicated bicycle exercise test were enrolled in the Finnish Cardiovascular Study (FINCAVAS). Exercise capacity was measured in metabolic equivalents, heart rate recovery as the decrease in heart rate from maximum to one minute post-exercise, and T-wave alternans by time-domain Modified Moving Average method. During 57-month median follow-up (interquartile range 35-78 months), 96 patients died of cardiovascular causes (primary endpoint) and 233 from any cause. All three parameters were independent predictors of cardiovascular mortality when analysed as continuous variables. Adding metabolic equivalents (p < 0.001), heart rate recovery (p = 0.002) or T-wave alternans (p = 0.01) to the linear model improved its predictive power for cardiovascular mortality. The combination of low exercise capacity (<6 metabolic equivalents), reduced heart rate recovery (≤12 beats/min) and elevated T-wave alternans (≥60 μV) yielded the highest hazard ratio for cardiovascular mortality of 16.5 (95% confidence interval 4.0-67.7, p < 0.001). Harrell's C index was 0.719 (confidence interval 0.665-0.772) for cardiovascular mortality with previously defined cutpoints (<8 units for metabolic equivalents, ≤18 beats/min for heart rate recovery and ≥60 μV for T-wave alternans). The prognostic capacity of the clinical exercise test is enhanced by combined analysis of exercise capacity, heart rate recovery and T-wave alternans. © The European Society of Cardiology 2014.

  13. [A new procedure for the estimation of physical fitness of patients during clinical rehabilitation using the 6-minute-walk-test].

    PubMed

    Marek, W; Marek, E; Vogel, P; Mückenhoff, K; Kotschy-Lang, N

    2008-11-01

    AIMS OF THE INVESTIGATION: The 6-minute-walk-test (6-MW) is an effective tool for measuring physical fitness in elderly patients. The increased walking distance is taken as a parameter for improved physical conditions. Frequently an unaltered walking distance is found after clinical treatment, but heart rate is significantly lower in the second challenge, indicating an improved physical fitness. This positive effect is not recognised when only the walking distance is analysed. An analysis of the 6-MW test was performed on 263 patients before and after 3 - 4 weeks clinical rehabilitation. In a control group of 26 patients 6-MW was repeated after recovery at the beginning and the end of the clinical treatment. Instrumented by a mobile pulse oximeter for recording oxygen saturation and heart rate, patients were instructed to walk as fast as they can do during 6 minutes. Measurements were performed every 30 seconds and printed out. Two new parameters, efficiency (E = S/f (C)), the ratio of distance and mean heart rate, and the theoretical increase in walking distance (S (z) = Delta f (C1)/Delta f (C2) x S (2) - S (1)) were introduced and tested. S (z) = theoretical increase in distance, Delta f (C1) = difference in heart rate at rest and mean heart rate at steady state during the first walk test with distance, S1. Delta f (C2), and S2 are measured during the second walk. Thus, the increase in distance is calculated under the assumption that the second walk test would have been performed by the patient with the same difference in heart rate that he/she achieved in the first walk. The patient groups walked 353 +/- 80 m at 106 +/- 14.3 beats/min in the 1st. 6-MW and 368 +/- 76.9 m at a heart rate of 105 +/- 14.0 beats/min in the final test. The increase of the walking distance was most significant in patients with shorter distances in the 1st 6-MW. A significant increase in the walking distance and in efficiency was found in patients with shorter walking distances or lower heart rates in the final test, using the numerical procedure described above. The patient's performance of the second walk test with an unchanged distance at a lower heart rate reveals an improved physical fitness. This is solely described by an increase by the parameter of efficiency, E. The calculation of the parameter, Sz, theoretical difference in walking distance (i. e., theoretical increase in almost all tests) provides a quantification of the effect of exercise training, even if the patient is not cooperative during the tests. Both parameters have proved to be suitable estimations for the assessment of physical fitness as a beneficial effect of clinical rehabilitation.

  14. Early-onset neonatal sepsis is associated with a high heart rate during automatically selected stationary periods.

    PubMed

    Nguyen, Nga; Vandenbroucke, Laurent; Hernández, Alfredo; Pham, Tu; Beuchée, Alain; Pladys, Patrick

    2017-05-01

    This study examined the heart rate variability characteristics associated with early-onset neonatal sepsis in a prospective, observational controlled study. Eligible patients were full-term neonates hospitalised with clinical signs that suggested early-onset sepsis and a C-reactive protein of >10 mg/L. Sepsis was considered proven in cases of symptomatic septicaemia, meningitis, pneumonia or enterocolitis. Heart rate variability parameters (n = 16) were assessed from five-, 15- and 30-minute stationary sequences automatically selected from electrocardiographic recordings performed at admission and compared with a control group using the U-test with post hoc Benjamini-Yekutieli correction. Stationary sequences corresponded to the periods with the lowest changes of heart rate variability over time. A total of 40 full-term infants were enrolled, including 14 with proven sepsis. The mean duration of the cardiac cycle length was lower in the proven sepsis group than in the control group (n = 11), without other significant changes in heart rate variability parameters. These durations, measured in five-minute stationary periods, were 406 (367-433) ms in proven sepsis group versus 507 (463-522) ms in the control group (p < 0.05). Early-onset neonatal sepsis was associated with a high mean heart rate measured during automatically selected stationary periods. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  15. Metoprolol vs ivabradine in patients with mitral stenosis in sinus rhythm.

    PubMed

    Agrawal, Vikas; Kumar, Niraj; Lohiya, Balalji; Sihag, Bhupendra K; Prajapati, Rajpal; Singh, T B; Subramanian, Geetha

    2016-10-15

    Severe mitral stenosis is usually symptomatic and is treated by BMV or surgery, whereas mild to moderate mitral stenosis is usually asymptomatic or mildly symptomatic and managed medically. Patients in the later group may become symptomatic during episodes of exercise and increased heart rate. Beta-blockers are frequently used in patients with mitral stenosis to control the heart rate and alleviate exercise-related symptoms. The objective of our study was to investigate the comparative efficacy of ivabradine versus metoprolol in patients with mitral stenosis in sinus rhythm. We studied 97 patients of mitral stenosis in sinus rhythm presented with exertional symptoms. The effectiveness of Metoprolol was compared with ivabradine in alleviating these exertional symptoms in a randomized, open label non crossover study. We also assessed various stress ECG parameters, 24 hour Holter parameters and 2D Echo parameters to objectively compare the effects of ivabradine and metoprolol in these patients. Ivabradine and metoprolol both were effective in controlling exertional symptoms. Significant improvement in objective parameters like TMT (work capacity, baseline heart rate and maximal heart rate) and 2D echocardiography (right ventricular systolic pressure) are seen with both drugs. Ivabradine controls the exertional symptoms significantly more than metoprolol. On head to head comparison there was a significant benefit of working capacity and heart rate at maximal exercise in favour of ivabradine. Ivabradine should be strongly considered in medical management of mitral stenosis patients where beta blockers are contraindicated such as reactive airway disease. The cost of ivabradine is higher than metoprolol which might possess constraints as most of the rheumatic heat disease patients belong to low socio economic status. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  16. The Effect of Adenotonsillectomy for Childhood Sleep Apnea on Cardiometabolic Measures.

    PubMed

    Quante, Mirja; Wang, Rui; Weng, Jia; Rosen, Carol L; Amin, Raouf; Garetz, Susan L; Katz, Eliot; Paruthi, Shalini; Arens, Raanan; Muzumdar, Hiren; Marcus, Carole L; Ellenberg, Susan; Redline, Susan

    2015-09-01

    Obstructive sleep apnea syndrome (OSAS) has been associated with cardiometabolic disease in adults. In children, this association is unclear. We evaluated the effect of early adenotonsillectomy (eAT) for treatment of OSAS on blood pressure, heart rate, lipids, glucose, insulin, and C-reactive protein. We also analyzed whether these parameters at baseline and changes at follow-up correlated with polysomnographic indices. Data collected at baseline and 7-mo follow-up were analyzed from a randomized controlled trial, the Childhood Adenotonsillectomy Trial (CHAT). Clinical referral setting from multiple centers. There were 464 children, ages 5 to 9.9 y with OSAS without severe hypoxemia. Randomization to eAT or Watchful Waiting with Supportive Care (WWSC). There was no significant change of cardiometabolic parameters over the 7-mo interval in the eAT group compared to WWSC group. However, overnight heart rate was incrementally higher in association with baseline OSAS severity (average heart rate increase of 3 beats per minute [bpm] for apnea-hypopnea index [AHI] of 2 versus 10; [standard error = 0.60]). Each 5-unit improvement in AHI and 5 mmHg improvement in peak end-tidal CO2 were estimated to reduce heart rate by 1 and 1.5 bpm, respectively. An increase in N3 sleep also was associated with small reductions in systolic blood pressure percentile. There is little variation in standard cardiometabolic parameters in children with obstructive sleep apnea syndrome (OSAS) but without severe hypoxemia at baseline or after intervention. Of all measures, overnight heart rate emerged as the most sensitive parameter of pediatric OSAS severity. Clinicaltrials.gov (#NCT00560859). © 2015 Associated Professional Sleep Societies, LLC.

  17. Facial Vibrotactile Stimulation Activates the Parasympathetic Nervous System: Study of Salivary Secretion, Heart Rate, Pupillary Reflex, and Functional Near-Infrared Spectroscopy Activity

    PubMed Central

    Hiraba, Hisao; Inoue, Motoharu; Gora, Kanako; Sato, Takako; Nishimura, Satoshi; Yamaoka, Masaru; Kumakura, Ayano; Ono, Shinya; Wakasa, Hirotugu; Nakayama, Enri; Abe, Kimiko; Ueda, Koichiro

    2014-01-01

    We previously found that the greatest salivation response in healthy human subjects is produced by facial vibrotactile stimulation of 89 Hz frequency with 1.9 μm amplitude (89 Hz-S), as reported by Hiraba et al. (2012, 20011, and 2008). We assessed relationships between the blood flow to brain via functional near-infrared spectroscopy (fNIRS) in the frontal cortex and autonomic parameters. We used the heart rate (HRV: heart rate variability analysis in RR intervals), pupil reflex, and salivation as parameters, but the interrelation between each parameter and fNIRS measures remains unknown. We were to investigate the relationship in response to established paradigms using simultaneously each parameter-fNIRS recording in healthy human subjects. Analysis of fNIRS was examined by a comparison of various values between before and after various stimuli (89 Hz-S, 114 Hz-S, listen to classic music, and “Ahh” vocalization). We confirmed that vibrotactile stimulation (89 Hz) of the parotid glands led to the greatest salivation, greatest increase in heart rate variability, and the most constricted pupils. Furthermore, there were almost no detectable differences between fNIRS during 89 Hz-S and fNIRS during listening to classical music of fans. Thus, vibrotactile stimulation of 89 Hz seems to evoke parasympathetic activity. PMID:24511550

  18. Behavioral correlates of heart rates of free-living Greater White-fronted Geese

    USGS Publications Warehouse

    Ely, Craig R.; Ward, D.H.; Bollinger, K.S.

    1999-01-01

    We simultaneously monitored the heart rate and behavior of nine free-living Greater White-fronted Geese (Anser albifrons) on their wintering grounds in northern California. Heart rates of wild geese were monitored via abdominally-implanted radio transmitters with electrodes that received electrical impulses of the heart and emitted a radio signal with each ventricular contraction. Post-operative birds appeared to behave normally, readily rejoining flocks and flying up to 15 km daily from night-time roost sites to feed in surrounding agricultural fields. Heart rates varied significantly among individuals and among behaviors, and ranged from less than 100 beats per minute (BPM) during resting, to over 400 BPM during flight. Heart rates varied from 80 to 140 BPM during non-strenuous activities such as walking, feeding, and maintenance activities, to about 180 BPM when birds became alert, and over 400 BPM when birds were startled, even if they did not take flight. Postflight heart rate recovery time averaged < 10 sec. During agonistic encounters, heart rate exceeded 400 BPM; heart rates during social interactions were not predictable solely from postures, as heart rates were context-dependent, and were highest in initial encounters among individuals. Instantaneous measures of physiological parameters, such as heart rate, are often better indicators of the degree of response to external stimuli than visual observations and can be used to improve estimates of energy expenditure based solely on activity data.

  19. Reversible heart rhythm complexity impairment in patients with primary aldosteronism

    NASA Astrophysics Data System (ADS)

    Lin, Yen-Hung; Wu, Vin-Cent; Lo, Men-Tzung; Wu, Xue-Ming; Hung, Chi-Sheng; Wu, Kwan-Dun; Lin, Chen; Ho, Yi-Lwun; Stowasser, Michael; Peng, Chung-Kang

    2015-08-01

    Excess aldosterone secretion in patients with primary aldosteronism (PA) impairs their cardiovascular system. Heart rhythm complexity analysis, derived from heart rate variability (HRV), is a powerful tool to quantify the complex regulatory dynamics of human physiology. We prospectively analyzed 20 patients with aldosterone producing adenoma (APA) that underwent adrenalectomy and 25 patients with essential hypertension (EH). The heart rate data were analyzed by conventional HRV and heart rhythm complexity analysis including detrended fluctuation analysis (DFA) and multiscale entropy (MSE). We found APA patients had significantly decreased DFAα2 on DFA analysis and decreased area 1-5, area 6-15, and area 6-20 on MSE analysis (all p < 0.05). Area 1-5, area 6-15, area 6-20 in the MSE study correlated significantly with log-transformed renin activity and log-transformed aldosterone-renin ratio (all p < = 0.01). The conventional HRV parameters were comparable between PA and EH patients. After adrenalectomy, all the altered DFA and MSE parameters improved significantly (all p < 0.05). The conventional HRV parameters did not change. Our result suggested that heart rhythm complexity is impaired in APA patients and this is at least partially reversed by adrenalectomy.

  20. Development of an infection screening system for entry inspection at airport quarantine stations using ear temperature, heart and respiration rates.

    PubMed

    Sun, Guanghao; Abe, Nobujiro; Sugiyama, Youhei; Nguyen, Quang Vinh; Nozaki, Kohei; Nakayama, Yosuke; Takei, Osamu; Hakozaki, Yukiya; Abe, Shigeto; Matsui, Takemi

    2013-01-01

    After the outbreak of severe acute respiratory syndrome (SARS) in 2003, many international airport quarantine stations conducted fever-based screening to identify infected passengers using infrared thermography for preventing global pandemics. Due to environmental factors affecting measurement of facial skin temperature with thermography, some previous studies revealed the limits of authenticity in detecting infectious symptoms. In order to implement more strict entry screening in the epidemic seasons of emerging infectious diseases, we developed an infection screening system for airport quarantines using multi-parameter vital signs. This system can automatically detect infected individuals within several tens of seconds by a neural-network-based discriminant function using measured vital signs, i.e., heart rate obtained by a reflective photo sensor, respiration rate determined by a 10-GHz non-contact respiration radar, and the ear temperature monitored by a thermography. In this paper, to reduce the environmental effects on thermography measurement, we adopted the ear temperature as a new screening indicator instead of facial skin. We tested the system on 13 influenza patients and 33 normal subjects. The sensitivity of the infection screening system in detecting influenza were 92.3%, which was higher than the sensitivity reported in our previous paper (88.0%) with average facial skin temperature.

  1. Patient-specific models of cardiac biomechanics

    NASA Astrophysics Data System (ADS)

    Krishnamurthy, Adarsh; Villongco, Christopher T.; Chuang, Joyce; Frank, Lawrence R.; Nigam, Vishal; Belezzuoli, Ernest; Stark, Paul; Krummen, David E.; Narayan, Sanjiv; Omens, Jeffrey H.; McCulloch, Andrew D.; Kerckhoffs, Roy C. P.

    2013-07-01

    Patient-specific models of cardiac function have the potential to improve diagnosis and management of heart disease by integrating medical images with heterogeneous clinical measurements subject to constraints imposed by physical first principles and prior experimental knowledge. We describe new methods for creating three-dimensional patient-specific models of ventricular biomechanics in the failing heart. Three-dimensional bi-ventricular geometry is segmented from cardiac CT images at end-diastole from patients with heart failure. Human myofiber and sheet architecture is modeled using eigenvectors computed from diffusion tensor MR images from an isolated, fixed human organ-donor heart and transformed to the patient-specific geometric model using large deformation diffeomorphic mapping. Semi-automated methods were developed for optimizing the passive material properties while simultaneously computing the unloaded reference geometry of the ventricles for stress analysis. Material properties of active cardiac muscle contraction were optimized to match ventricular pressures measured by cardiac catheterization, and parameters of a lumped-parameter closed-loop model of the circulation were estimated with a circulatory adaptation algorithm making use of information derived from echocardiography. These components were then integrated to create a multi-scale model of the patient-specific heart. These methods were tested in five heart failure patients from the San Diego Veteran's Affairs Medical Center who gave informed consent. The simulation results showed good agreement with measured echocardiographic and global functional parameters such as ejection fraction and peak cavity pressures.

  2. Probability of detection of clinical seizures using heart rate changes.

    PubMed

    Osorio, Ivan; Manly, B F J

    2015-08-01

    Heart rate-based seizure detection is a viable complement or alternative to ECoG/EEG. This study investigates the role of various biological factors on the probability of clinical seizure detection using heart rate. Regression models were applied to 266 clinical seizures recorded from 72 subjects to investigate if factors such as age, gender, years with epilepsy, etiology, seizure site origin, seizure class, and data collection centers, among others, shape the probability of EKG-based seizure detection. Clinical seizure detection probability based on heart rate changes, is significantly (p<0.001) shaped by patients' age and gender, seizure class, and years with epilepsy. The probability of detecting clinical seizures (>0.8 in the majority of subjects) using heart rate is highest for complex partial seizures, increases with a patient's years with epilepsy, is lower for females than for males and is unrelated to the side of hemisphere origin. Clinical seizure detection probability using heart rate is multi-factorially dependent and sufficiently high (>0.8) in most cases to be clinically useful. Knowledge of the role that these factors play in shaping said probability will enhance its applicability and usefulness. Heart rate is a reliable and practical signal for extra-cerebral detection of clinical seizures originating from or spreading to central autonomic network structures. Copyright © 2015 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  3. Effect of Missing Inter-Beat Interval Data on Heart Rate Variability Analysis Using Wrist-Worn Wearables.

    PubMed

    Baek, Hyun Jae; Shin, JaeWook

    2017-08-15

    Most of the wrist-worn devices on the market provide a continuous heart rate measurement function using photoplethysmography, but have not yet provided a function to measure the continuous heart rate variability (HRV) using beat-to-beat pulse interval. The reason for such is the difficulty of measuring a continuous pulse interval during movement using a wearable device because of the nature of photoplethysmography, which is susceptible to motion noise. This study investigated the effect of missing heart beat interval data on the HRV analysis in cases where pulse interval cannot be measured because of movement noise. First, we performed simulations by randomly removing data from the RR interval of the electrocardiogram measured from 39 subjects and observed the changes of the relative and normalized errors for the HRV parameters according to the total length of the missing heart beat interval data. Second, we measured the pulse interval from 20 subjects using a wrist-worn device for 24 h and observed the error value for the missing pulse interval data caused by the movement during actual daily life. The experimental results showed that mean NN and RMSSD were the most robust for the missing heart beat interval data among all the parameters in the time and frequency domains. Most of the pulse interval data could not be obtained during daily life. In other words, the sample number was too small for spectral analysis because of the long missing duration. Therefore, the frequency domain parameters often could not be calculated, except for the sleep state with little motion. The errors of the HRV parameters were proportional to the missing data duration in the presence of missing heart beat interval data. Based on the results of this study, the maximum missing duration for acceptable errors for each parameter is recommended for use when the HRV analysis is performed on a wrist-worn device.

  4. Research on fatigue driving pre-warning system based on multi-information fusion

    NASA Astrophysics Data System (ADS)

    Zhao, Xuyang; Ye, Wenwu

    2018-05-01

    With the development of science and technology, transportation network has grown faster. But at the same time, the quantity of traffic accidents due to fatigue driving grows faster as well. In the meantime, fatigue driving has been one of the main causes of traffic accidents. Therefore, it is indispensable for us to study the detection of fatigue driving to help to driving safety. There are numerous approaches in discrimination method. Each type of method has its reasonable theoretical basis, but the disadvantages of traditional fatigue driving detection methods have been more and more obvious since we study the traditional physiology and psychological features of fatigue drivers. So we set up a new system based on multi-information fusion and pattern recognition theory. In the paper, the fatigue driving pre-warning system discriminates fatigue by analyzing the characteristic parameters, the parameters derived from the steering wheel angle, the driver's power of gripping and the heart rate. And the data analysis system is established based on fuzzy C-means clustering theory. Finally, KNN classifier is used to establish the relation between feature indexes and fatigue degree. It is verified that the system has the better accuracy, agility and robustness according to our confirmatory experiment.

  5. Heart Rate Variability and Drawing Impairment in Hypoxemic COPD

    ERIC Educational Resources Information Center

    Incalzi, Raffaele Antonelli; Corsonello, Andrea; Trojano, Luigi; Pedone, Claudio; Acanfora, Domenico; Spada, Aldo; D'Addio, Gianni; Maestri, Roberto; Rengo, Franco; Rengo, Giuseppe

    2009-01-01

    We studied 54 patients with hypoxemic chronic obstructive pulmonary disease (COPD). The Mini Mental State Examination and the Mental Deterioration Battery were used for neuropsychological assessment. Heart rate variability (HRV) was assessed based on 24-h Holter ECG recording. Mann-Whitney test was used to compare HRV parameters of patients…

  6. Effect of electromagnetic field accompanying the magnetic resonance imaging on human heart rate variability - a pilot study.

    PubMed

    Derkacz, Arkadiusz; Gawrys, Jakub; Gawrys, Karolina; Podgorski, Maciej; Magott-Derkacz, Agnieszka; Poreba, Rafał; Doroszko, Adrian

    2018-06-01

    The effect of electromagnetic field on cardiovascular system in the literature is defined in ambiguous way. The aim of this study was to evaluate the effect of electromagnetic field on the heart rate variability (HRV) during the examination with magnetic resonance. Forty-two patients underwent Holter ECG heart monitoring for 30 minutes twice: immediately before and after the examination with magnetic resonance imaging (MRI). HRV was analysed by assessing a few selected time and spectral parameters. Is has been shown that standard deviation of NN intervals (SDNN) and very low frequency rates increased, whereas the low frequency:high frequency parameter significantly decreased following the MRI examination. These results show that MRI may affect the HRV most likely by changing the sympathetic-parasympathetic balance.

  7. Simultaneous measurement of instantaneous heart rate and chest wall plethysmography in short-term, metronome guided heart rate variability studies: suitability for assessment of autonomic dysfunction.

    PubMed

    Perring, S; Jones, E

    2003-08-01

    Instantaneous heart rate and chest wall motion were measured using a 3-lead ECG and an air pressure chest wall plethysmography system. Chest wall plethysmography traces were found to accurately represent the breathing pattern as measured by spirometry (average correlation coefficient 0.944); though no attempt was made to calibrate plethysmography voltage output to tidal volume. Simultaneous measurements of heart rate and chest wall motion were made for short periods under metronome guided breathing at 6 breaths per minute. The average peak to trough heart rate change per breath cycle (AVEMAX) and maximum correlation between heart rate and breathing cycle (HRBRCORR) were measured. Studies of 44 normal volunteers indicated clear inverse correlation of heart rate variability parameters with age (AVEMAX R = -0.502, P < 0.001) but no significant change in HRBRCORR with age (R = -0.115). Comparison of normal volunteers with diabetics with no history of symptoms associated with autonomic failure indicated significant lower heart rate variability in diabetics (P = 0.005 for AVEMAX) and significantly worse correlation between heart rate and breathing (P < 0.001 for HRBRCORR). Simultaneous measurement of heart rate and breathing offers the possibility of more sensitive diagnosis of autonomic failure in a simple bedside test and gives further insight into the nature of cardio-ventilatory coupling.

  8. Hyperthyroidism is characterized by both increased sympathetic and decreased vagal modulation of heart rate: evidence from spectral analysis of heart rate variability.

    PubMed

    Chen, Jin-Long; Chiu, Hung-Wen; Tseng, Yin-Jiun; Chu, Woei-Chyn

    2006-06-01

    The clinical manifestations of hyperthyroidism resemble those of the hyperadrenergic state. This study was designed to evaluate the impact of hyperthyroidism on the autonomic nervous system (ANS) and to investigate the relationship between serum thyroid hormone concentrations and parameters of spectral heart rate variability (HRV) analysis in hyperthyroidism. Thirty-two hyperthyroid Graves' disease patients (mean age 31 years) and 32 sex-, age-, and body mass index (BMI)-matched normal control subjects were recruited to receive one-channel electrocardiogram (ECG) recording. The cardiac autonomic nervous function was evaluated by the spectral analysis of HRV, which indicates the autonomic modulation of the sinus node. The correlation coefficients between serum thyroid hormone concentrations and parameters of the spectral HRV analysis were also computed. The hyperthyroid patients revealed significant differences (P < 0.001) compared with the controls in the following HRV parameters: a decrease in total power (TP), very low frequency power (VLF), low frequency power (LF), high frequency power (HF), and HF in normalized units (HF%); and an increase in LF in normalized units (LF%) and in the ratio of LF to HF (LF/HF). After correction of hyperthyroidism in 28 patients, all of the above parameters were restored to levels comparable to those of the controls. In addition, serum thyroid hormone concentrations showed significant correlations with spectral HRV parameters. Hyperthyroidism is in a sympathovagal imbalanced state, characterized by both increased sympathetic and decreased vagal modulation of the heart rate. These autonomic dysfunctions can be detected simultaneously by spectral analysis of HRV, and the spectral HRV parameters could reflect the disease severity in hyperthyroid patients.

  9. Parasympathetic reinnervation accompanied by improved post-exercise heart rate recovery and quality of life in heart transplant recipients.

    PubMed

    Imamura, Teruhiko; Kinugawa, Koichiro; Okada, Ikuko; Kato, Naoko; Fujino, Takeo; Inaba, Toshiro; Maki, Hisataka; Hatano, Masaru; Kinoshita, Osamu; Nawata, Kan; Kyo, Shunei; Ono, Minoru

    2015-01-01

    Although sympathetic reinnervation is accompanied by the improvement of exercise tolerability during the first years after heart transplantation (HTx), little is known about parasympathetic reinnervation and its clinical impact. We enrolled 21 recipients (40 ± 16 years, 71% male) who had received successive cardiopulmonary exercise testing at 6 months, and 1 and 2 years after HTx. Exercise parameters such as peak oxygen consumption or achieved maximum load remained unchanged, whereas recovery parameters including heart rate (HR) recovery during 2 minutes and the delay of peak HR, which are influenced by parasympathetic activity, improved significantly during post-HTx 2 years (P < 0.05 for both). HR variability was analysed at post-HTx 6 months in 18 recipients, and high frequency power, representing parasympathetic activity, was significantly associated with the 2 recovery parameters (P < 0.05 for all). We also assessed quality of life using the Minnesota Living with Heart Failure (HF) Questionnaire at post-HTx 6 months and 2 years in the same 18 recipients, and those with improved recovery parameters enjoyed a better HF-specific quality of life (P < 0.05 for both). In conclusion, parasympathetic reinnervation emerges along with improved post-exercise recovery ability of HR and quality of life during post-HTx 2 years.

  10. [The influence of physical exercise on heart rate variability].

    PubMed

    Gajek, Jacek; Zyśko, Dorota; Negrusz-Kawecka, Marta; Halawa, Bogumił

    2003-03-01

    Heart rate variability is controlled by the influence of autonomic nervous system, whereas one part of the system modulates the activity of the other. There is evidence of increased sympathetic activity in patients (pts) with essential hypertension. The aim of the study was to assess the persisting influence of increased sympathetic activity 30 min after moderate physical exercise on heart rate variability in patients with arterial hypertension. The study was performed in 19 patients (10 women, mean age 52.7 +/- 9.5 years and 9 men, mean age 37.7 +/- 8.8 years) with stage I (6 pts) and stage II (13 pts) arterial hypertension. All studied pts had sinus rhythm, were free of diabetes, coronary heart disease and congestive heart failure. 24-hour Holter monitoring was performed and for 30 min before the exercise test the pts stayed in supine rest. The exercise tests were performed between 10 and 11 a.m. Immediately after the exercise all pts stayed in supine position for 30 min. The heart rate variability parameters were studied using Holter monitoring system Medilog Optima Jet and were then analysed statistically. The mean energy expenditure during the exercise was 5.8 +/- 1.1 METs and the maximal heart rate was 148.1 +/- 20.3 bpm. All studied HRV parameters were significantly different in the assessed time period compared to the baseline values (p < 0.001). Significant correlation was found between the age of the studied patients and the mean RR interval, what can be considered as a hyperkinetic (hyperadrenergic) circulatory status and shorter RR interval in younger pts. Significant negative correlation between the age and SDNN parameter (r = -0.65, p < 0.001), 30 min after the exercise mirrors the prolonged adrenergic influence in older pts. The present study shows that the influence of moderate physical exercise on heart rate variability in pts with essential hypertension is extended over 30 min period after exercise and is more pronounced in older pts. The studies on HRV should be performed at longer time intervals after exercise.

  11. Heart rate variability in patients with systemic lupus erythematosus: a systematic review and methodological considerations.

    PubMed

    Matusik, P S; Matusik, P T; Stein, P K

    2018-07-01

    Aim The aim of this review was to summarize current knowledge about the scientific findings and potential clinical utility of heart rate variability measures in patients with systemic lupus erythematosus. Methods PubMed, Embase and Scopus databases were searched for the terms associated with systemic lupus erythematosus and heart rate variability, including controlled vocabulary, when appropriate. Articles published in English and available in full text were considered. Finally, 11 publications were selected, according to the systematic review protocol and were analyzed. Results In general, heart rate variability, measured in the time and frequency domains, was reported to be decreased in patients with systemic lupus erythematosus compared with controls. In some systemic lupus erythematosus studies, heart rate variability was found to correlate with inflammatory markers and albumin levels. A novel heart rate variability measure, heart rate turbulence onset, was shown to be increased, while heart rate turbulence slope was decreased in systemic lupus erythematosus patients. Reports of associations of changes in heart rate variability parameters with increasing systemic lupus erythematosus activity were inconsistent, showing decreasing heart rate variability or no relationship. However, the low/high frequency ratio was, in some studies, reported to increase with increasing disease activity or to be inversely correlated with albumin levels. Conclusions Patients with systemic lupus erythematosus have abnormal heart rate variability, which reflects cardiac autonomic dysfunction and may be related to inflammatory cytokines but not necessarily to disease activity. Thus measurement of heart rate variability could be a useful clinical tool for monitoring autonomic dysfunction in systemic lupus erythematosus, and may potentially provide prognostic information.

  12. Rate of change of heart size before congestive heart failure in dogs with mitral regurgitation.

    PubMed

    Lord, P; Hansson, K; Kvart, C; Häggström, J

    2010-04-01

    The objective of the study was to examine the changes in vertebral heart scale, and left atrial and ventricular dimensions before and at onset of congestive heart failure in cavalier King Charles spaniels with mitral regurgitation. Records and radiographs from 24 cavalier King Charles spaniels with mitral regurgitation were used. Vertebral heart scale (24 dogs), and left atrial dimension and left ventricular end diastolic and end systolic diameters (18 dogs) and their rate of increase were measured at intervals over years to the onset of congestive heart failure. They were plotted against time to onset of congestive heart failure. Dimensions and rates of change of all parameters were highest at onset of congestive heart failure, the difference between observed and chance outcome being highly significant using a two-tailed chi-square test (P<0.001). The left heart chambers increase in size rapidly only in the last year before the onset of congestive heart failure. Increasing left ventricular end systolic dimension is suggestive of myocardial failure before the onset of congestive heart failure. Rate of increase of heart dimensions may be a useful indicator of impending congestive heart failure.

  13. Military Performance and Health Monitoring in Extreme Environments

    DTIC Science & Technology

    2009-10-01

    radiation and wind to give a true temperature reading . At high ambient temperatures, in particular in combination with solar radiation, objects may...Equivital multi-sensor unit enabling the real-time, parallel and continuous assessment of EKG (and heart rate), respiration (and respiration rate), skin

  14. Sodium Tanshinone IIA Sulfonate Improves Hemodynamic Parameters, Cytokine Release, and Multi-Organ Damage in Endotoxemia Rabbits.

    PubMed

    Ma, Shaolei; Wang, Xian; Wang, Yujie; Zuo, Xiangrong

    2018-05-08

    BACKGROUND The aim of this study was to evaluate the protective effects of sodium tanshinone IIA sulfonate (STS) on hemodynamic parameters, cytokine release, and multiple organ damage in an animal model of lipopolysaccharide (LPS)-induced endotoxemia. MATERIAL AND METHODS Twenty-four rabbits were randomly divided into 3 groups: control (n=8), LPS (n=8), and STS pretreatment + LPS (n=8) groups. With arterial invasive monitoring, hemodynamic variables were observed at 30 min before and at 0, 10, 20, 30, 60, 120, 180, 240, and 300 min after LPS injection. Circulatory inflammatory cytokines, including tumor necrosis factor-α (TNF-α) and interleukin-10 (IL-10), and relevant biochemical markers, including arterial partial pressure of oxygen (PaO2), plasma cardiac troponin I (cTnI), alanine aminotransferase (ALT), and creatinine (Cr), were measured at each time point. At the end of the experiment, all rabbits were sacrificed; histopathological examination of the heart, lung, liver, and kidney tissue was performed and organ injury was semi-quantitatively scored for each organ. RESULTS Mean arterial pressure (MAP) and heart rate (HR) significantly decreased within 30 min and again after 120 min following LPS injection. However, STS pretreatment gradually normalized MAP and HR after 120 min following LPS injection. In addition, STS ameliorated LPS-induced decrease of PaO2, LPS-induced increase of TNF-α, cTnI, and ALT, and enhanced LPS-induced increase of IL-10. Moreover, STS reduced heart, lung, and liver histopathologic injury. CONCLUSIONS STS can significantly stabilize LPS-induced hemodynamic deterioration, regulate inflammatory cytokine secretion, and protect heart, lung, and liver in rabbits.

  15. Determinants of heart rate turbulence in individuals without apparent heart disease and in patients with stable coronary artery disease.

    PubMed

    Pinnacchio, Gaetano; Lanza, Gaetano Antonio; Stazi, Alessandra; Careri, Giulia; Coviello, Ilaria; Mollo, Roberto; Crea, Filippo

    2015-12-01

    To assess the characteristics and determinants of heart rate turbulence (HRT) in individuals without any apparent heart disease and in patients with coronary artery disease (CAD). Heart rate turbulence parameters, turbulence onset (TO), and turbulence slope (TS) were calculated on 24 h electrocardiogram recordings in 209 individuals without any heart disease (group 1) and in 157 CAD patients (group 2). In group 1, only age independently predicted abnormal TO (≥0%) [odds ratio (OR), 1.05; P<0.001], while predictors of abnormal TS (≤2.5 ms/RR) were age (OR, 0.85; P < 0.001) and hypertension (OR, 0.19; P = 0.028). In group 2 patients, only age independently predicted TO (OR, 1.03; P = 0.038), while age (OR, 0.90; P = 0.001) and left ventricular ejection fraction (LVEF; OR, 1.07; P = 0.008) predicted TS. Heart rate turbulence values were different in groups 1 and 2. Turbulence onset was (mean, standard deviation) -1.80 ± 2.24 vs. -0.73 ± 1.61%, respectively (P < 0.001), whereas TS was (median, interquartile interval) 5.83 (3.25-10.55) vs. 2.93 (1.73-5.81) ms/RR, respectively (P < 0.001). Coronary artery disease group, however, did not predict abnormal HRT parameters in multivariable analyses, both in the whole population and when comparing two subgroups matched for age and gender. Age and (for TS) LVEF, indeed, were the only independent predictors of abnormal HRT. Age is a major HRT determinant both in subjects without any apparent heart disease and in stable CAD patients. Hypertension and LVEF contribute independently to HRT in these two groups, respectively. Coronary artery disease group was not by itself associated with abnormal HRT parameters in multivariable analyses. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  16. Influence of Prolonged Spaceflight on Heart Rate and Oxygen Uptake Kinetics

    NASA Astrophysics Data System (ADS)

    Hoffmann, U.; Moore, A.; Drescher, U.

    2013-02-01

    During prolonged spaceflight, physical training is used to minimize cardiovascular deconditioning. Measurement of the kinetics of cardiorespiratory parameters, in particular the kinetic analysis of heart rate, respiratory and muscular oxygen uptake, provides useful information with regard to the efficiency and regulation of the cardiorespiratory system. Practically, oxygen uptake kinetics can only be measured at the lung site (V’O2 resp). The dynamics of V’O2 resp, however, is not identical with the dynamics at the site of interest: skeletal muscle. Eight Astronauts were tested pre- and post-flight using pseudo random binary workload changes between 30 and 80 W. Their kinetic responses of heart rate, respiratory as well as muscular V’O2 kinetics were estimated by using time-series analysis. Statistical analysis revealed that the kinetic responses of respiratory as well as muscular V’O2 kinetics are slowed post-flight than pre-flight. Heart rate seems not to be influenced following flight. The influence of other factors (e. g. astronauts’ exercise training) may impact these parameters and is an area for future studies.

  17. Simulated sudden increase in geomagnetic activity and its effect on heart rate variability: Experimental verification of correlation studies.

    PubMed

    Caswell, Joseph M; Singh, Manraj; Persinger, Michael A

    2016-08-01

    Previous research investigating the potential influence of geomagnetic factors on human cardiovascular state has tended to converge upon similar inferences although the results remain relatively controversial. Furthermore, previous findings have remained essentially correlational without accompanying experimental verification. An exception to this was noted for human brain activity in a previous study employing experimental simulation of sudden geomagnetic impulses in order to assess correlational results that had demonstrated a relationship between geomagnetic perturbations and neuroelectrical parameters. The present study employed the same equipment in a similar procedure in order to validate previous findings of a geomagnetic-cardiovascular dynamic with electrocardiography and heart rate variability measures. Results indicated that potential magnetic field effects on frequency components of heart rate variability tended to overlap with previous correlational studies where low frequency power and the ratio between low and high frequency components of heart rate variability appeared affected. In the present study, a significant increase in these particular parameters was noted during geomagnetic simulation compared to baseline recordings. Copyright © 2016 The Committee on Space Research (COSPAR). Published by Elsevier Ltd. All rights reserved.

  18. The effect of relaxing massage on heart rate and heart rate variability in purebred Arabian racehorses.

    PubMed

    Kowalik, Sylwester; Janczarek, Iwona; Kędzierski, Witold; Stachurska, Anna; Wilk, Izabela

    2017-04-01

    The objective of this study was to assess the effect of relaxing massage on the heart rate (HR) and heart rate variability (HRV) in young racehorses during their first racing season. In the study, 72 Purebred Arabian racehorses were included. The study was implemented during the full race season. The horses from control and experimental groups were included in regular race training 6 days a week. The horses from the experimental group were additionally subject to the relaxing massage 3 days a week during the whole study. HR and HRV were assumed as indicators of the emotional state of the horses. The measurements were taken six times, every 4-5 weeks. The HRV parameters were measured at rest, during grooming and saddling the horse and during warm-up walking under a rider. The changes of the parameters throughout the season suggest that the relaxing massage may be effectively used to make the racehorses more relaxed and calm. Moreover, the horses from the experimental group had better race performance records. © 2016 Japanese Society of Animal Science.

  19. Estimating 'lost heart beats' rather than reductions in heart rate during the intubation of critically-ill children.

    PubMed

    Jones, Peter; Ovenden, Nick; Dauger, Stéphane; Peters, Mark J

    2014-01-01

    Reductions in heart rate occur frequently in children during critical care intubation and are currently considered the gold standard for haemodynamic instability. Our objective was to estimate loss of heart beats during intubation and compare this to reduction in heart rate alone whilst testing the impact of atropine pre-medication. Data were extracted from a prospective 2-year cohort study of intubation ECGs from critically ill children in PICU/Paediatric Transport. A three step algorithm was established to exclude variation in pre-intubation heart rate (using a 95%CI limit derived from pre-intubation heart rate variation of the children included), measure the heart rate over time and finally the estimate the numbers of lost beats. 333 intubations in children were eligible for inclusion of which 245 were available for analysis (74%). Intubations where the fall in heart rate was less than 50 bpm were accompanied almost exclusively by less than 25 lost beats (n = 175, median 0 [0-1]). When there was a reduction of >50 bpm there was a poor correlation with numbers of lost beats (n = 70, median 42 [15-83]). During intubation the median number of lost beats was 8 [1]-[32] when atropine was not used compared to 0 [0-0] when atropine was used (p<0.001). A reduction in heart rate during intubation of <50 bpm reliably predicted a minimal loss of beats. When the reduction in heart rate was >50 bpm the heart rate was poorly predictive of lost beats. A study looking at the relationship between lost beats and cardiac output needs to be performed. Atropine reduces both fall in heart rate and loss of beats. Similar area-under-the-curve methodology may be useful for estimating risk when biological parameters deviate outside normal range.

  20. Heart rate variability enhances the prognostic value of established parameters in patients with congestive heart failure.

    PubMed

    Krüger, C; Lahm, T; Zugck, C; Kell, R; Schellberg, D; Schweizer, M W F; Kübler, W; Haass, M

    2002-12-01

    This prospective study evaluated whether heart rate variability (HRV) assessed from Holter ECG has prognostic value in addition to established parameters in patients with congestive heart failure (CHF). The study included 222 patients with CHF due to dilated or ischemic cardiomyopathy (left ventricular ejection fraction LVEF 21+/-1%; mean+/-SEM). During a mean follow-up of 15+/-1 months, 38 (17%) patients died and 45 (20%) were hospitalized due to worsening of CHF. The HRV parameter SDNN (standard deviation of all intervals between normal beats) was significantly lower in non-surviving or hospitalized than in event-free patients (118+/-6 vs 142+/-5 ms), as were LVEF (18+/-1 vs 23+/-1%), and peak oxygen uptake during exercise (peak VO(2)) (12.8+/-0.5 vs 15.6+/-0.5 ml/min/kg). While each of these parameters was a risk predictor in univariate analysis, multivariate analysis revealed that HRV provides both independent and additional prognostic information with respect to the risk 'cardiac mortality or deterioration of CHF'. It is concluded that the determination of HRV enhances the prognostic power given by the most widely used parameters LVEF and peak VO(2) in the prediction of mortality or deterioration of CHF and thus enables to improve risk stratification.

  1. A study of the 200-metre fast walk test as a possible new assessment tool to predict maximal heart rate and define target heart rate for exercise training of coronary heart disease patients.

    PubMed

    Casillas, Jean-Marie; Joussain, Charles; Gremeaux, Vincent; Hannequin, Armelle; Rapin, Amandine; Laurent, Yves; Benaïm, Charles

    2015-02-01

    To develop a new predictive model of maximal heart rate based on two walking tests at different speeds (comfortable and brisk walking) as an alternative to a cardiopulmonary exercise test during cardiac rehabilitation. Evaluation of a clinical assessment tool. A Cardiac Rehabilitation Department in France. A total of 148 patients (133 men), mean age of 59 ±9 years, at the end of an outpatient cardiac rehabilitation programme. Patients successively performed a 6-minute walk test, a 200 m fast-walk test (200mFWT), and a cardiopulmonary exercise test, with measure of heart rate at the end of each test. An all-possible regression procedure was used to determine the best predictive regression models of maximal heart rate. The best model was compared with the Fox equation in term of predictive error of maximal heart rate using the paired t-test. Results of the two walking tests correlated significantly with maximal heart rate determined during the cardiopulmonary exercise test, whereas anthropometric parameters and resting heart rate did not. The simplified predictive model with the most acceptable mean error was: maximal heart rate = 130 - 0.6 × age + 0.3 × HR200mFWT (R(2) = 0.24). This model was superior to the Fox formula (R(2) = 0.138). The relationship between training target heart rate calculated from measured reserve heart rate and that established using this predictive model was statistically significant (r = 0.528, p < 10(-6)). A formula combining heart rate measured during a safe simple fast walk test and age is more efficient than an equation only including age to predict maximal heart rate and training target heart rate. © The Author(s) 2014.

  2. Toward Hypertension Prediction Based on PPG-Derived HRV Signals: a Feasibility Study.

    PubMed

    Lan, Kun-Chan; Raknim, Paweeya; Kao, Wei-Fong; Huang, Jyh-How

    2018-04-21

    Heart rate variability (HRV) is often used to assess the risk of cardiovascular disease, and data on this can be obtained via electrocardiography (ECG). However, collecting heart rate data via photoplethysmography (PPG) is now a lot easier. We investigate the feasibility of using the PPG-based heart rate to estimate HRV and predict diseases. We obtain three months of PPG-based heart rate data from subjects with and without hypertension, and calculate the HRV based on various forms of time and frequency domain analysis. We then apply a data mining technique to this estimated HRV data, to see if it is possible to correctly identify patients with hypertension. We use six HRV parameters to predict hypertension, and find SDNN has the best predictive power. We show that early disease prediction is possible through collecting one's PPG-based heart rate information.

  3. Olfactory bulbectomy induces rapid and stable changes in basal and stress-induced locomotor activity, heart rate and body temperature responses in the home cage.

    PubMed

    Vinkers, C H; Breuer, M E; Westphal, K G C; Korte, S M; Oosting, R S; Olivier, B; Groenink, L

    2009-03-03

    Olfactory bulbectomy (OBX) in rats causes several behavioral and neurochemical changes. However, the extent and onset of physiological and behavioral changes induced after bulbectomy have been little examined. Male Sprague-Dawley rats received telemetric implants. Before and immediately after OBX surgery, basal and stress-induced heart rate, body temperature, and locomotor activity were measured in the home cage in sham (n=9) and OBX animals (n=11). Stress was induced using novel cage stress or witness stress. Bulbectomized animals differed physiologically and behaviorally from shams. Nocturnally, OBX animals were significantly more active compared with shams, had a higher core body temperature and displayed a decreased heart rate variability. During the light period, OBX animals had a significantly lower basal heart rate and a reduced heart rate variability. These effects became apparent 2-3 days after OBX surgery, and were stable over time. After witness stress, OBX animals showed smaller autonomic (body temperature and heart rate) responses compared with shams, but showed no difference in locomotor responses. In contrast, novel cage stress led to increased locomotor responses in OBX rats compared with sham rats, while no differences were found in autonomic responses. Removal of the olfactory bulbs results in rapid, stable and persistent changes in basal locomotor activity, body temperature, heart rate and heart rate variability. Although the sleep-wake cycle of these parameters is not altered, increases in circadian amplitude are apparent within 3 days after surgery. This indicates that physiological changes in the OBX rat are the immediate result of olfactory bulb removal. Further, stress responsivity in OBX rats depends on stressor intensity. Bulbectomized rats display smaller temperature and heart rate responses to less intense witness stress compared with sham rats. Increased locomotor responses to more intense novel cage stress are present in the home cage as well as the open field. The present study shows that olfactory bulbectomy has rapid and persistent influence on basal and stress-induced physiological parameters.

  4. Heart rate turbulence.

    PubMed

    Cygankiewicz, Iwona

    2013-01-01

    Heart rate turbulence (HRT) is a baroreflex-mediated biphasic reaction of heart rate in response to premature ventricular beats. Heart rate turbulence is quantified by: turbulence onset (TO) reflecting the initial acceleration of heart rate following premature beat and turbulence slope (TS) describing subsequent deceleration of heart rate. Abnormal HRT identifies patients with autonomic dysfunction or impaired baroreflex sensitivity due to variety of disorders, but also may reflect changes in autonomic nervous system induced by different therapeutic modalities such as drugs, revascularization, or cardiac resynchronization therapy. More importantly, impaired HRT has been shown to identify patients at high risk of all-cause mortality and sudden death, particularly in postinfarction and congestive heart failure patients. It should be emphasized that abnormal HRT has a well-established role in stratification of postinfarction and heart failure patients with relatively preserved left ventricular ejection fraction. The ongoing clinical trials will document whether HRT can be used to guide implantation of cardioverter-defibrillators in this subset of patients, not covered yet by ICD guidelines. This review focuses on the current state-of-the-art knowledge regarding clinical significance of HRT in detection of autonomic dysfunction and regarding the prognostic significance of this parameter in predicting all-cause mortality and sudden death. © 2013.

  5. Heart Rate Variability Dynamics for the Prognosis of Cardiovascular Risk

    PubMed Central

    Ramirez-Villegas, Juan F.; Lam-Espinosa, Eric; Ramirez-Moreno, David F.; Calvo-Echeverry, Paulo C.; Agredo-Rodriguez, Wilfredo

    2011-01-01

    Statistical, spectral, multi-resolution and non-linear methods were applied to heart rate variability (HRV) series linked with classification schemes for the prognosis of cardiovascular risk. A total of 90 HRV records were analyzed: 45 from healthy subjects and 45 from cardiovascular risk patients. A total of 52 features from all the analysis methods were evaluated using standard two-sample Kolmogorov-Smirnov test (KS-test). The results of the statistical procedure provided input to multi-layer perceptron (MLP) neural networks, radial basis function (RBF) neural networks and support vector machines (SVM) for data classification. These schemes showed high performances with both training and test sets and many combinations of features (with a maximum accuracy of 96.67%). Additionally, there was a strong consideration for breathing frequency as a relevant feature in the HRV analysis. PMID:21386966

  6. Heart rate variability (HRV) in deep breathing tests and 5-min short-term recordings: agreement of ear photoplethysmography with ECG measurements, in 343 subjects.

    PubMed

    Weinschenk, Stefan W; Beise, Reinhard D; Lorenz, Jürgen

    2016-08-01

    We analyzed heart rate variability (HRV) taken by ECG and photoplethysmography (PPG) to assess their agreement. We also analyzed the sensitivity and specificity of PPG to identify subjects with low HRV as an example of its potential use for clinical applications. The HRV parameters: mean heart rate (HR), amplitude, and ratio of heart rate oscillation (E-I difference, E/I ratio), RMSSD, SDNN, and Power LF, were measured during 1-min deep breathing tests (DBT) in 343 individuals, followed by a 5-min short-term HRV (s-HRV), where the HRV parameters: HR, SD1, SD2, SDNN, Stress Index, Power HF, Power LF, Power VLF, and Total Power, were determined as well. Parameters were compared through correlation analysis and agreement analysis by Bland-Altman plots. PPG derived parameters HR and SD2 in s-HRV showed better agreement than SD1, Power HF, and stress index, whereas in DBT HR, E/I ratio and SDNN were superior to Power LF and RMSSD. DBT yielded stronger agreement than s-HRV. A slight overestimation of PPG HRV over HCG HRV was found. HR, Total Power, and SD2 in the s-HRV, HR, Power LF, and SDNN in the DBT showed high sensitivity and specificity to detect individuals with poor HRV. Cutoff percentiles are given for the future development of PPG-based devices. HRV measured by PPG shows good agreement with ECG HRV when appropriate parameters are used, and PPG-based devices can be employed as an easy screening tool to detect individuals with poor HRV, especially in the 1-min DBT test.

  7. Assessment of the Cardiac Autonomic Nervous System in Mercury-Exposed Individuals via Post-Exercise Heart Rate Recovery.

    PubMed

    Yilmaz, Omer Hinc; Karakulak, Ugur Nadir; Tutkun, Engin; Bal, Ceylan; Gunduzoz, Meside; Ercan Onay, Emine; Ayturk, Mehmet; Tek Ozturk, Mujgan; Alaguney, Mehmet Erdem

    The aim of this study was to assess exercise heart rate recovery (HRR) indices in mercury-exposed individuals when evaluating their cardiac autonomic function. Twenty-eight mercury-exposed individuals and 28 healthy controls were enrolled. All the subjects underwent exercise testing and transthoracic echocardiography. The HRR indices were calculated by subtracting the first- (HRR1), second- (HRR2) and third-minute (HRR3) heart rates from the maximal heart rate. The two groups were evaluated in terms of exercise test parameters, especially HRR, and a correlation analysis was performed between blood, 24-hour urine and hair mercury levels and the test parameters. The mercury-exposed and control groups were similar in age (37.2 ± 6.6 vs. 36.9 ± 9.0 years), had an identical gender distribution (16 females and 12 males) and similar left ventricular ejection fractions (65.5 ± 3.1 vs. 65.4 ± 3.1%). The mean HRR1 [25.6 ± 6.5 vs. 30.3 ± 8.2 beats per min (bpm); p = 0.009], HRR2 (43.5 ± 5.3 vs. 47.8 ± 5.5 bpm; p = 0.010) and HRR3 (56.8 ± 5.1 vs. 59.4 ± 6.3 bpm; p = 0.016) values were significantly lower in the mercury-exposed group than in the healthy controls. However, there were no significant correlations between blood, urine and hair mercury levels and exercise test parameters. Mercury-exposed individuals had lower HRR indices than normal subjects. In these individuals, mercury exposure measurements did not show correlations with the exercise test parameters, but age did show a negative correlation with these parameters. Therefore, cardiac autonomic functions might be involved in cases of mercury exposure. © 2016 S. Karger AG, Basel.

  8. A three-lead, programmable, and microcontroller-based electrocardiogram generator with frequency domain characteristics of heart rate variability.

    PubMed

    Wei, Ying-Chieh; Wei, Ying-Yu; Chang, Kai-Hsiung; Young, Ming-Shing

    2012-04-01

    The objective of this study is to design and develop a programmable electrocardiogram (ECG) generator with frequency domain characteristics of heart rate variability (HRV) which can be used to test the efficiency of ECG algorithms and to calibrate and maintain ECG equipment. We simplified and modified the three coupled ordinary differential equations in McSharry's model to a single differential equation to obtain the ECG signal. This system not only allows the signal amplitude, heart rate, QRS-complex slopes, and P- and T-wave position parameters to be adjusted, but can also be used to adjust the very low frequency, low frequency, and high frequency components of HRV frequency domain characteristics. The system can be tuned to function with HRV or not. When the HRV function is on, the average heart rate can be set to a value ranging from 20 to 122 beats per minute (BPM) with an adjustable variation of 1 BPM. When the HRV function is off, the heart rate can be set to a value ranging from 20 to 139 BPM with an adjustable variation of 1 BPM. The amplitude of the ECG signal can be set from 0.0 to 330 mV at a resolution of 0.005 mV. These parameters can be adjusted either via input through a keyboard or through a graphical user interface (GUI) control panel that was developed using LABVIEW. The GUI control panel depicts a preview of the ECG signal such that the user can adjust the parameters to establish a desired ECG morphology. A complete set of parameters can be stored in the flash memory of the system via a USB 2.0 interface. Our system can generate three different types of synthetic ECG signals for testing the efficiency of an ECG algorithm or calibrating and maintaining ECG equipment. © 2012 American Institute of Physics

  9. The Effect of Adenotonsillectomy for Childhood Sleep Apnea on Cardiometabolic Measures

    PubMed Central

    Quante, Mirja; Wang, Rui; Weng, Jia; Rosen, Carol L.; Amin, Raouf; Garetz, Susan L.; Katz, Eliot; Paruthi, Shalini; Arens, Raanan; Muzumdar, Hiren; Marcus, Carole L.; Ellenberg, Susan; Redline, Susan

    2015-01-01

    Study Objectives: Obstructive sleep apnea syndrome (OSAS) has been associated with cardiometabolic disease in adults. In children, this association is unclear. We evaluated the effect of early adenotonsillectomy (eAT) for treatment of OSAS on blood pressure, heart rate, lipids, glucose, insulin, and C-reactive protein. We also analyzed whether these parameters at baseline and changes at follow-up correlated with polysomnographic indices. Design: Data collected at baseline and 7-mo follow-up were analyzed from a randomized controlled trial, the Childhood Adenotonsillectomy Trial (CHAT). Setting: Clinical referral setting from multiple centers. Participants: There were 464 children, ages 5 to 9.9 y with OSAS without severe hypoxemia. Interventions: Randomization to eAT or Watchful Waiting with Supportive Care (WWSC). Measurements and Results: There was no significant change of cardiometabolic parameters over the 7-mo interval in the eAT group compared to WWSC group. However, overnight heart rate was incrementally higher in association with baseline OSAS severity (average heart rate increase of 3 beats per minute [bpm] for apnea-hypopnea index [AHI] of 2 versus 10; [standard error = 0.60]). Each 5-unit improvement in AHI and 5 mmHg improvement in peak end-tidal CO2 were estimated to reduce heart rate by 1 and 1.5 bpm, respectively. An increase in N3 sleep also was associated with small reductions in systolic blood pressure percentile. Conclusions: There is little variation in standard cardiometabolic parameters in children with obstructive sleep apnea syndrome (OSAS) but without severe hypoxemia at baseline or after intervention. Of all measures, overnight heart rate emerged as the most sensitive parameter of pediatric OSAS severity. Clinical Trial Registration: Clinicaltrials.gov (#NCT00560859) Citation: Quante M, Wang R, Weng J, Rosen CL, Amin R, Garetz SL, Katz E, Paruthi S, Arens R, Muzumdar H, Marcus CL, Ellenberg S, Redline S. The effect of adenotonsillectomy for childhood sleep apnea on cardiometabolic measures. SLEEP 2015;38(9):1395–1403. PMID:25669177

  10. A three-lead, programmable, and microcontroller-based electrocardiogram generator with frequency domain characteristics of heart rate variability

    NASA Astrophysics Data System (ADS)

    Wei, Ying-Chieh; Wei, Ying-Yu; Chang, Kai-Hsiung; Young, Ming-Shing

    2012-04-01

    The objective of this study is to design and develop a programmable electrocardiogram (ECG) generator with frequency domain characteristics of heart rate variability (HRV) which can be used to test the efficiency of ECG algorithms and to calibrate and maintain ECG equipment. We simplified and modified the three coupled ordinary differential equations in McSharry's model to a single differential equation to obtain the ECG signal. This system not only allows the signal amplitude, heart rate, QRS-complex slopes, and P- and T-wave position parameters to be adjusted, but can also be used to adjust the very low frequency, low frequency, and high frequency components of HRV frequency domain characteristics. The system can be tuned to function with HRV or not. When the HRV function is on, the average heart rate can be set to a value ranging from 20 to 122 beats per minute (BPM) with an adjustable variation of 1 BPM. When the HRV function is off, the heart rate can be set to a value ranging from 20 to 139 BPM with an adjustable variation of 1 BPM. The amplitude of the ECG signal can be set from 0.0 to 330 mV at a resolution of 0.005 mV. These parameters can be adjusted either via input through a keyboard or through a graphical user interface (GUI) control panel that was developed using LABVIEW. The GUI control panel depicts a preview of the ECG signal such that the user can adjust the parameters to establish a desired ECG morphology. A complete set of parameters can be stored in the flash memory of the system via a USB 2.0 interface. Our system can generate three different types of synthetic ECG signals for testing the efficiency of an ECG algorithm or calibrating and maintaining ECG equipment.

  11. Effects of age and mild cognitive impairment on the pain response system.

    PubMed

    Kunz, Miriam; Mylius, Veit; Schepelmann, Karsten; Lautenbacher, Stefan

    2009-01-01

    Both age and dementia have been shown to have an effect on nociception and pain processing. The question arises whether mild cognitive impairment (MCI), which is thought to be a transitional stage between normal ageing and dementia, is also associated with alterations in pain processing. The aim of the present study was to answer this question by investigating the impact of age and MCI on the pain response system. Forty young subjects, 45 cognitively unimpaired elderly subjects and 42 subjects with MCI were investigated by use of an experimental multi-method approach. The subjects were tested for their subjective (pain ratings), motor (RIII reflex), facial (Facial Action Coding System) and their autonomic (sympathetic skin response and evoked heart rate response) responses to noxious electrical stimulation of the nervus suralis. We found significant group differences in the autonomic responses to noxious stimulation. The sympathetic skin response amplitude was significantly reduced in the cognitively unimpaired elderly subjects compared to younger subjects and to an even greater degree in subjects with MCI. The evoked heart rate response was reduced to a similar degree in both groups of aged subjects. Regression analyses within the two groups of the elderly subjects revealed that age and, in the MCI group, cognitive status were significant predictors of the decrease in autonomic responsiveness to noxious stimulation. Except for the autonomic parameters, no other pain parameter differed between the three groups. The pain response system appeared to be quite unaltered in MCI patients compared to cognitively unimpaired individuals of the same age. Only the sympathetic responsiveness qualified as an indicator of early aging effects as well as of pathophysiology associated with MCI, which both seemed to affect the pain system independently from each other.

  12. Heart rate reactivity associated to positive and negative food and non-food visual stimuli.

    PubMed

    Kuoppa, Pekka; Tarvainen, Mika P; Karhunen, Leila; Narvainen, Johanna

    2016-08-01

    Using food as a stimuli is known to cause multiple psychophysiological reactions. Heart rate variability (HRV) is common tool for assessing physiological reactions in autonomic nervous system. However, the findings in HRV related to food stimuli have not been consistent. In this paper the quick changes in HRV related to positive and negative food and non-food visual stimuli are investigated. Electrocardiogram (ECG) was measured from 18 healthy females while being stimulated with the pictures. Subjects also filled Three-Factor Eating Questionnaire to determine their eating behavior. The inter-beat-interval time series and the HRV parameters were extracted from the ECG. The quick change in HRV parameters were studied by calculating the change from baseline value (10 s window before stimulus) to value after the onset of the stimulus (10 s window during stimulus). The paired t-test showed significant difference between positive and negative food pictures but not between positive and negative non-food pictures. All the HRV parameters decreased for positive food pictures while they stayed the same or increased a little for negative food pictures. The eating behavior characteristic cognitive restraint was negatively correlated with HRV parameters that describe decreasing of heart rate.

  13. Microprocessor-based long term cardiorespirography. II. Status evaluation in term and premature newborns.

    PubMed

    Hörnchen, H; Betz, R; Kotlarek, F; Roebruck, P

    1983-01-01

    In 1965 URBACH et al. and RUDOLPH et al. [35, 39] described a loss of heart rate variability in severely ill neonates. In this study we investigated the correlation between instantaneous heart rate patterns and status diagnosis. We used a microprocessor-based cardiorespirography system. Seventy five newborn infants (51 prematures and 24 term neonates) were studied for about 12 hours each. Twenty nine patients had a second record after the first investigation. Parameters were: Type of frequency and oscillation, long time variability (LTV), short time variability (STV) and the newly introduced P-value (maximal difference between two successive R-peaks in five minutes). We found clear differences between the study groups. With increasing severity of illness mean values ("group mean values") of long time variability, short time variability and P-value decreased. Fixed heart rate became predominant. The most pronounced loss of heart rate variability was seen in infants with severe intracranial bleeding, thus offering a tentative diagnosis. For statistical analysis long time variability and the silent oscillation type have been proved as best parameters for this diagnosis. Severely decreased heart rate variations also have been seen in infants with acute renal failure--possibly because of brain edema--, after application of muscle relaxants, repeated doses of sedatives, and after prolonged anesthesia. Otherwise, the heart rate variability was probably dependent on age and gestational age in prematures and newborn infants without intracranial bleeding. It is possible to use microprocessor-based long time cardiorespirography as a simple screening method for the diagnosis of neonatal intracerebral bleeding. In future experiences transcutaneous measurements of oxygen tension should be included.

  14. Use of Audible and Chart-recorded Ultrasonography to Monitor Fetal Heart Rate and Uterine Blood Flow Parameters in Cattle

    USDA-ARS?s Scientific Manuscript database

    The objective of the present study was to evaluate the use of audible chart-recorded doppler ultrasonography (DUS) to monitor both uterine blood flow and fetal heart rate (FHR) during pregnancy in dairy cattle. Possible applications of DUS include the monitoring of fetal distress when a pregnancy be...

  15. Balancing tissue perfusion demands: cardiovascular dynamics of Cancer magister during exposure to low salinity and hypoxia.

    PubMed

    McGaw, Iain J; McMahon, Brian R

    2003-01-01

    Decapod crustaceans inhabit aquatic environments that are frequently subjected to changes in salinity and oxygen content. The physiological responses of decapod crustaceans to either salinity or hypoxia are well documented; however, there are many fewer reports on the physiological responses during exposure to these parameters in combination. We investigated the effects of simultaneous and sequential combinations of low salinity and hypoxia on the cardiovascular physiology of the Dungeness crab, Cancer magister. Heart rate, as well as haemolymph flow rates through the anterolateral, hepatic, sternal and posterior arteries were measured using a pulsed-Doppler flowmeter. Summation of flows allowed calculation of cardiac output and division of this by heart rate yielded stroke volume. When hypoxia and low salinity were encountered simultaneously, the observed changes in cardiac properties tended to be a mix of both factors. Hypoxia caused a bradycardia, whereas exposure to low salinity was associated with a tachycardia. However, the hypoxic conditions had the dominant effect on heart rate. Although hypoxia caused an increase in stroke volume of the heart, the low salinity had a more pronounced effect, causing an overall decrease in stroke volume. The patterns of haemolymph flow through the arterial system also varied when hypoxia and low salinity were offered together. The resulting responses were a mix of those resulting from exposure to either parameter alone. When low salinity and hypoxia were offered sequentially, the parameter experienced first tended to have the dominant effect on cardiac function and haemolymph flows. Low salinity exposure was associated with an increase in heart rate, a decrease in stroke volume and cardiac output, and a concomitant decrease in haemolymph flow rates. Subsequent exposure to hypoxic conditions caused a slight decrease in rate, but other cardiovascular variables were largely unaffected. In contrast, when low salinity followed acclimation to hypoxic conditions, apart from an increased heart rate, there were no other cardiovascular changes associated with the low salinity episode. The implications of these changes in cardiovascular dynamics are discussed in relation to physiological mechanisms and the ecology of decapod crustaceans, in hypoxic or low salinity environments. Copyright 2003, Wiley-Liss, Inc.

  16. The effects of N-acetylcysteine on cisplatin-induced changes of cardiodynamic parameters within coronary autoregulation range in isolated rat hearts.

    PubMed

    Rosic, Gvozden; Selakovic, Dragica; Joksimovic, Jovana; Srejovic, Ivan; Zivkovic, Vladimir; Tatalović, Nikola; Orescanin-Dusic, Zorana; Mitrovic, Slobodanka; Ilic, Milena; Jakovljevic, Vladimir

    2016-02-03

    The aim of this study was to evaluate the effects of chronic NAC administration along with cisplatin on cisplatin-induced cardiotoxicity by means of coronary flow (CF), cardiodynamic parameters, oxidative stress markers and morphological changes in isolated rat heart. Isolated hearts of Wistar albino rats (divided into four groups: control, cisplatin, NAC and cisplatin+NAC group) were perfused according to Langendorff technique at constant coronary perfusion pressure starting at 50 and gradually increased to 65, 80, 95 and 110 cm H2O to evaluate cardiodynamic parameters within autoregulation range. Samples of coronary venous effluent (CVE) were collected for determination of CF and biochemical assays, and heart tissue samples for biochemical assays and histopathological examination. Cisplatin treatment decreased CF and heart rate, and increased left ventricular systolic pressure and maximum left ventricular pressure development rate. Cisplatin increased H2O2 and TBARS, but decreased NO2(-) levels in CVE. In tissue samples, cisplatin reduced pathological alterations in myocardium and coronary vessels, with no changes in the amount of total glutathione, as well as in activity of glutathione peroxidase and glutathione reductase. NAC coadministration, by reducing oxidative damage, attenuated cisplatin-induced changes of cardiodynamic and oxidative stress parameters, as well as morphological changes in myocardium and coronary vasculature. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  17. Allometric relationship of postmolt net ion uptake, ventilation, and circulation in the freshwater crayfish Procambarus clarkii: intraspecific scaling.

    PubMed

    Zanotto, F P; Wheatly, M G; Reiber, C L; Gannon, A T; Jalles-Filho, E

    2004-01-01

    There are few intraspecific studies relating physiological parameters to body mass. This study relates scaling of ionic regulation and respiratory parameters with body mass in crayfish (Procambarus clarkii). These animals were chosen because of their direct development, spanning four orders of magnitude in body mass. Usually, these animals are hyperregulators and must maintain hemolymph electrolyte levels above those in the ambient freshwater. This is especially important in the postmolt, when ion imbalance can occur. Maintaining hemolymph ion levels above ambient involves active processes that are independently related to metabolic rate, ventilation, and circulation. Therefore, this study investigates relationships among size and ionic regulation, heart rate, and ventilation in crayfish, spanning a size range of 0.003-24 g. Postmolt net ion uptake of Ca, titratable base, Na, Cl, and NH4 increase with body mass (positive allometry) with slopes of 0.92, 0.79, 0.90, 0.84, and 0.87, respectively. Between 72% and 97% of variation in ionic regulation was related to body mass. The slopes differed from each other for Ca and titratable base but not for Na, Cl, and NH4. For heart rate and ventilation rate, different relationships were derived for animals smaller and larger than 0.01 g (between first and third instar). Animals larger than 0.01 g show a negative allometric relationship between heart rate and body size ([body mass](0.15)), while smaller animals show positive allometry with body size, but only 29% of variation in heart rate is explained by body size alone. For ventilation rates, the negative allometry with body size for animals larger than 0.01 g is present, but less than 15% of variation in ventilation rate is explained by size, while for smaller animals the size dependency disappears. Based on these results, predictions of physiological parameters such as ionic regulation based on body size are useful in crayfish, but estimates of respiratory parameters and body size should be used with caution.

  18. Temporal phasing of locomotor activity, heart rate rhythmicity, and core body temperature is disrupted in VIP receptor 2-deficient mice.

    PubMed

    Hannibal, Jens; Hsiung, Hansen M; Fahrenkrug, Jan

    2011-03-01

    Neurons of the brain's biological clock located in the hypothalamic suprachiasmatic nucleus (SCN) generate circadian rhythms of physiology (core body temperature, hormone secretion, locomotor activity, sleep/wake, and heart rate) with distinct temporal phasing when entrained by the light/dark (LD) cycle. The neuropeptide vasoactive intestinal polypetide (VIP) and its receptor (VPAC2) are highly expressed in the SCN. Recent studies indicate that VIPergic signaling plays an essential role in the maintenance of ongoing circadian rhythmicity by synchronizing SCN cells and by maintaining rhythmicity within individual neurons. To further increase the understanding of the role of VPAC2 signaling in circadian regulation, we implanted telemetric devices and simultaneously measured core body temperature, spontaneous activity, and heart rate in a strain of VPAC2-deficient mice and compared these observations with observations made from mice examined by wheel-running activity. The study demonstrates that VPAC2 signaling is necessary for a functional circadian clock driving locomotor activity, core body temperature, and heart rate rhythmicity, since VPAC2-deficient mice lose the rhythms in all three parameters when placed under constant conditions (of either light or darkness). Furthermore, although 24-h rhythms for three parameters are retained in VPAC2-deficient mice during the LD cycle, the temperature rhythm displays markedly altered time course and profile, rising earlier and peaking ∼4-6 h prior to that of wild-type mice. The use of telemetric devices to measure circadian locomotor activity, temperature, and heart rate, together with the classical determination of circadian rhythms of wheel-running activity, raises questions about how representative wheel-running activity may be of other behavioral parameters, especially when animals have altered circadian phenotype.

  19. The influence of low-frequency magnetic field on plasma antioxidant capacity and heart rate.

    PubMed

    Ciejka, Elzbieta B; Goraca, Anna

    2009-01-01

    Low-frequency magnetic field is widely applied as magnetotherapy in physiotherapeutic treatment. Recognition of positive and negative effects of the magnetic field has been the subject of numerous studies. Experimental studies concern, among others, the effect of this field on the heart rate and plasma antioxidant capacity. The aim of the study was to check whether a time-variable magnetic field of constant frequency and induction affects the heart rate and plasma antioxidant capacity. The tests were performed on Spraque-Dawley rats exposed to the magnetic field of the following parameters: frequency - 40 Hz, induction - 7 mT, time of exposure - 30 and 60 minutes. The measurements of ECG and plasma antioxidant capacity expressed in the number of reduced iron ions were performed on experimental animals: before, after a single exposure and after 14 days of exposure. A significant decrease of the heart rate was observed after 14 days of exposure. A variable magnetic field of the parameters: frequency - 40 Hz, induction - 7 mT and exposure time of 14 days caused an increase of the organism antioxidant defence, whereas a variable magnetic field of the frequency of 40 Hz, induction - 7 mT and exposure time 60 minutes for 14 days caused a significant decrease of the organism antioxidant defence. The exposure time affects heart rate, plasma antioxidant capacity and the organism defense ability against free radicals.

  20. Variations from morning to afternoon of middle cerebral and umbilical artery blood flow, and fetal heart rate variability, and fetal characteristics in the normally developing fetus.

    PubMed

    Avitan, Tehila; Sanders, Ari; Brain, Ursula; Rurak, Dan; Oberlander, Tim F; Lim, Ken

    2018-05-01

    To determine if there are changes in maternal uterine blood flow, fetal brain blood flow, fetal heart rate variability, and umbilical blood flow between morning (AM) and afternoon (PM) in healthy, uncomplicated pregnancies. In this prospective study, 68 uncomplicated singleton pregnancies (mean 35 + 0.7 weeks gestation) underwent a standard observational protocol at both 08:00 (AM) and 13:30 (PM) of the same day. This protocol included Doppler measurements of uterine, umbilical, and fetal middle cerebral artery (MCA) volume flow parameters (flow, HR, peak systolic velocity [PSV], PI, and RI) followed by computerized cardiotocography. Standard descriptive statistics, χ 2 and t tests were used where appropriate. P < .05 was considered significant. A significant increase in MCA flow and MCA PSV was observed in the PM compared to the AM. This was accompanied by a fall in MCA resistance. Higher umbilical artery resistance indices were also observed in the PM compared to AM. In contrast, fetal heart rate characteristics, maternal uterine artery Doppler flow and resistance indices did not vary significantly between the AM and PM. In normal pregnancies, variations in fetal cerebral and umbilical blood flow parameters were observed between AM and PM independent of other fetal movements or baseline fetal heart rate. In contrast, uterine flow parameters remained stable across the day. These findings may have implications for the use of serial Doppler parameters used to guide clinical management in high-risk pregnancies. © 2017 Wiley Periodicals, Inc.

  1. Heart rate variability changes in business process outsourcing employees working in shifts.

    PubMed

    Kunikullaya, Kirthana U; Kirthi, Suresh K; Venkatesh, D; Goturu, Jaisri

    2010-10-31

    Irregular and poor quality sleep is common in business process outsourcing (BPO) employees due to continuous shift working. The influence of this on the cardiac autonomic activity was investigated by the spectral analysis of heart rate variability (HRV). 36 night shift BPO employees (working from 22:00 to 06:00h) and 36 age and sex matched day shift BPO employees (working from 08:00 to 16:00h) were recruited for the study. Five minute electrocardiogram (ECG) was recorded in all the subjects. Heart rate variability was analyzed by fast Fourier transformation using RMS Vagus HRV software. The results were analyzed using Mann Whitney U test, Student t-test, Wilcoxon signed rank test and were expressed as mean ± SD. Sleepiness was significantly higher among night shift workers as measured by Epworth Sleepiness Scale (p<0.001). Night shift BPO employees were found to have a trend towards lower values of vagal parameters - HF power (ms(2)), and higher values of sympathovagal parameters like LF Power (ms(2)) and the LF/HF power (%) suggesting decreased vagal activity and sympathetic over activity, when compared to day shift employees. However, HRV parameters did not vary significantly between the day shift employees and night shift workers baseline values, and also within the night shift group. Night shift working increased the heart rate and shifted the sympathovagal balance towards sympathetic dominance and decreased vagal parameters of HRV. This is an indicator of unfavorable change in the myocardial system, and thus shows increased risk of cardiovascular disease among the night shift employees.

  2. MDMA-Induced Dissociative State not Mediated by the 5-HT2A Receptor

    PubMed Central

    Puxty, Drew J.; Ramaekers, Johannes G.; de la Torre, Rafael; Farré, Magí; Pizarro, Neus; Pujadas, Mitona; Kuypers, Kim P. C.

    2017-01-01

    Previous research has shown that a single dose of MDMA induce a dissociative state, by elevating feelings of depersonalization and derealization. Typically, it is assumed that action on the 5-HT2A receptor is the mechanism underlying these psychedelic experiences. In addition, other studies have shown associations between dissociative states and biological parameters (heart rate, cortisol), which are elevated by MDMA. In order to investigate the role of the 5-HT2 receptor in the MDMA-induced dissociative state and the association with biological parameters, a placebo-controlled within-subject study was conducted including a single oral dose of MDMA (75 mg), combined with placebo or a single oral dose of the 5-HT2 receptor blocker ketanserin (40 mg). Twenty healthy recreational MDMA users filled out a dissociative states scale (CADSS) 90 min after treatments, which was preceded and followed by assessment of a number of biological parameters (cortisol levels, heart rate, MDMA blood concentrations). Findings showed that MDMA induced a dissociative state but this effect was not counteracted by pre-treatment with ketanserin. Heart rate was the only biological parameter that correlated with the MDMA-induced dissociative state, but an absence of correlation between these measures when participants were pretreated with ketanserin suggests an absence of directional effects of heart rate on dissociative state. It is suggested that the 5-HT2 receptor does not mediate the dissociative effects caused by a single dose of MDMA. Further research is needed to determine the exact neurobiology underlying this effect and whether these effects contribute to the therapeutic potential of MDMA. PMID:28744219

  3. MDMA-Induced Dissociative State not Mediated by the 5-HT2A Receptor.

    PubMed

    Puxty, Drew J; Ramaekers, Johannes G; de la Torre, Rafael; Farré, Magí; Pizarro, Neus; Pujadas, Mitona; Kuypers, Kim P C

    2017-01-01

    Previous research has shown that a single dose of MDMA induce a dissociative state, by elevating feelings of depersonalization and derealization. Typically, it is assumed that action on the 5-HT 2A receptor is the mechanism underlying these psychedelic experiences. In addition, other studies have shown associations between dissociative states and biological parameters (heart rate, cortisol), which are elevated by MDMA. In order to investigate the role of the 5-HT 2 receptor in the MDMA-induced dissociative state and the association with biological parameters, a placebo-controlled within-subject study was conducted including a single oral dose of MDMA (75 mg), combined with placebo or a single oral dose of the 5-HT 2 receptor blocker ketanserin (40 mg). Twenty healthy recreational MDMA users filled out a dissociative states scale (CADSS) 90 min after treatments, which was preceded and followed by assessment of a number of biological parameters (cortisol levels, heart rate, MDMA blood concentrations). Findings showed that MDMA induced a dissociative state but this effect was not counteracted by pre-treatment with ketanserin. Heart rate was the only biological parameter that correlated with the MDMA-induced dissociative state, but an absence of correlation between these measures when participants were pretreated with ketanserin suggests an absence of directional effects of heart rate on dissociative state. It is suggested that the 5-HT 2 receptor does not mediate the dissociative effects caused by a single dose of MDMA. Further research is needed to determine the exact neurobiology underlying this effect and whether these effects contribute to the therapeutic potential of MDMA.

  4. The relation of autonomic function to physical fitness in patients suffering from alcohol dependence.

    PubMed

    Herbsleb, Marco; Schulz, Steffen; Ostermann, Stephanie; Donath, Lars; Eisenträger, Daniela; Puta, Christian; Voss, Andreas; Gabriel, Holger W; Bär, Karl-Jürgen

    2013-10-01

    Reduced cardio-vascular health has been found in patients suffering from alcohol dependence. Low cardio-respiratory fitness is an independent predictor of cardio-vascular disease. We investigated physical fitness in 22 alcohol-dependent patients 10 days after acute alcohol withdrawal and compared results with matched controls. The standardized 6-min walk test (6 MWT) was used to analyze the relationship of autonomic dysfunction and physical fitness. Ventilatory indices and gas exchanges were assessed using a portable spiroergometric system while heart rate recordings were obtained separately. We calculated walking distance, indices of heart rate variability and efficiency parameters of heart rate and breathing. In addition, levels of exhaled carbon monoxide were measured in all participants to account for differences in smoking behaviour. Multivariate analyses of variance (MANOVA) were performed to investigate differences between patients and controls with regard to autonomic and efficiency parameters. Patients walked a significantly shorter distance in comparison to healthy subjects during the 6 MWT. Significantly decreased heart rate variability was observed before and after the test in patients when compared to controls, while no such difference was observed during exercise. The efficiency parameters indicated significantly reduced efficiency in physiological regulation when the obtained parameters were normalized to the distance. The 6 MWT is an easily applied instrument to measure physical fitness in alcohol dependent patients. It can also be used during exercise interventions. Reduced physical fitness, as observed in our study, might partly be caused by autonomic dysfunction, leading to less efficient regulation of physiological processes during exercise. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  5. Influence of red jersey color on physical parameters in combat sports.

    PubMed

    Dreiskaemper, Dennis; Strauss, Bernd; Hagemann, Norbert; Büsch, Dirk

    2013-02-01

    Hill and Barton (2005) showed that fighters in tae kwon do, boxing, and wrestling who wore red jerseys during the 2004 Olympic Games won more often than those wearing blue jerseys. Regarding these results, this study investigated the effects of jersey color during a combat situation on fighters' physical parameters of strength and heart rate. An artificial, experimental combat situation was created in which the color of sport attire was assigned randomly. Fourteen pairs of male athletes matched for weight, height, and age had to fight each other: once in a red jersey and once in a blue. Heart rate (before, during, and after the fight) and strength (before the fight) were tested wearing the blue and the red jerseys. Participants wearing red jerseys had significantly higher heart rates and significantly higher pre-contest values on the strength test. Results showed that participants' body functions are influenced by wearing red equipment.

  6. Smart Vest: wearable multi-parameter remote physiological monitoring system.

    PubMed

    Pandian, P S; Mohanavelu, K; Safeer, K P; Kotresh, T M; Shakunthala, D T; Gopal, Parvati; Padaki, V C

    2008-05-01

    The wearable physiological monitoring system is a washable shirt, which uses an array of sensors connected to a central processing unit with firmware for continuously monitoring physiological signals. The data collected can be correlated to produce an overall picture of the wearer's health. In this paper, we discuss the wearable physiological monitoring system called 'Smart Vest'. The Smart Vest consists of a comfortable to wear vest with sensors integrated for monitoring physiological parameters, wearable data acquisition and processing hardware and remote monitoring station. The wearable data acquisition system is designed using microcontroller and interfaced with wireless communication and global positioning system (GPS) modules. The physiological signals monitored are electrocardiogram (ECG), photoplethysmogram (PPG), body temperature, blood pressure, galvanic skin response (GSR) and heart rate. The acquired physiological signals are sampled at 250samples/s, digitized at 12-bit resolution and transmitted wireless to a remote physiological monitoring station along with the geo-location of the wearer. The paper describes a prototype Smart Vest system used for remote monitoring of physiological parameters and the clinical validation of the data are also presented.

  7. Changes in Physiological Parameters Induced by Indoor Simulated Driving: Effect of Lower Body Exercise at Mid-Term Break

    PubMed Central

    Liang, Wen Chieh; Yuan, John; Sun, Deh Chuan; Lin, Ming Han

    2009-01-01

    The study monitored physiological parameter changes after 120-min of simulated driving. Blood pressures, heart rate (HR), heart rate variability (HRV) and palm temperatures were measured using an ANSWatch® monitor. Subjects were divided into two groups (A & B). Both groups performed 2-hour driving, but group B additionally took a 15-min exercise break. Heart rate, systolic pressure, LF/HF, and palm temperature decreased for group A after driving; for group B only HR and palm temperatures decreased. HRV and parasympathetic indices HF(AU) and HF(NU) increased for group A, while HRV and sympathetic index LF(AU) increased in group B. Group A had higher fatigue scores than group B. ANS activation may overcome some fatigue symptoms, but the recovery is nonetheless incomplete. Exercise break is proven to be an effective remedy, especially if accompanied by the ANS actions. The normalized parasympathetic index HF(NU), the normalized sympathetic index LF(NU), and the sympatho-vagal balance index LF/HF are three most promising parameters that could be further developed to monitor driver fatigue. PMID:22399979

  8. The non-contact heart rate measurement system for monitoring HRV.

    PubMed

    Huang, Ji-Jer; Yu, Sheng-I; Syu, Hao-Yi; See, Aaron Raymond

    2013-01-01

    A noncontact ECG monitoring and analysis system was developed using capacitive-coupled device integrated to a home sofa. Electrodes were placed on the backrest of a sofa separated from the body with only the chair covering and the user's clothing. The study also incorporates measurements using different fabric materials, and a pure cotton material was chosen to cover the chair's backrest. The material was chosen to improve the signal to noise ratio. The system is initially implemented on a home sofa and is able to measure non-contact ECG through thin cotton clothing and perform heart rate analysis to calculate the heart rate variability (HRV) parameters. It was also tested under different conditions and results from reading and sleeping exhibited a stable ECG. Subsequently, results from our calculated HRV were found to be identical to those of a commercially available HRV analyzer. However, HRV parameters are easily affected by motion artifacts generated during drinking or eating with the latter producing a more severe disturbance. Lastly, parameters measured are saved on a cloud database, providing users with a long-term monitoring and recording for physiological information.

  9. Pain and cardiorespiratory responses of children during physiotherapy after heart surgery.

    PubMed

    Araujo, Adriana Sanches Garcia; Klamt, Jyrson Guilherme; Vicente, Walter Villela de Andrade; Garcia, Luis Vicente

    2014-01-01

    The aim of the present study was to determine the occurrence of pain and changes in blood pressure, heart rate, respiratory rate, and arterial oxygen saturation associated with physiotherapy in children undergoing cardiac surgery. Eighteen extubated children were assessed for the presence of pain using the face, legs, activity, cry, consolability scale, and blood pressure, heart rate, respiratory rate and arterial oxygen saturation were simultaneously recorded. The physiological parameters were measured at the following time periods: immediately before physiotherapy, five and 10 minutes after the beginning of physiotherapy, and five minutes after its end. Pain was assessed immediately before physiotherapy, ten minutes after the beginning of physiotherapy and five minutes after its end. Pain and physiological changes were assessed by the Friedman test and the correlation between the physiological parameters and the pain scores was assessed by the Spearman test. Pain increased during physiotherapy and decreased significantly after it compared to pre-physiotherapy scores. Systolic blood pressure and heart rate increased significantly after 10 minutes of the beginning of physiotherapy. Arterial oxygen saturation tended to decrease during physiotherapy and to increase after it, although without significance. The correlation between pain scores and the physiological variables was significant only for systolic blood pressure and heart rate ten minutes after the beginning of physiotherapy. Manipulation after the beginning of physiotherapy seems to be accompanied by significant pain and by important associated cardiovascular changes. Apparent analgesia and improved respiratory function were observed after respiratory physiotherapy.

  10. A fast non-contact imaging photoplethysmography method using a tissue-like model

    NASA Astrophysics Data System (ADS)

    McDuff, Daniel J.; Blackford, Ethan B.; Estepp, Justin R.; Nishidate, Izumi

    2018-02-01

    Imaging photoplethysmography (iPPG) allows non-contact, concomitant measurement and visualization of peripheral blood flow using just an RGB camera. Most iPPG methods require a window of temporal data and complex computation, this makes real-time measurement and spatial visualization impossible. We present a fast,"window-less", non-contact imaging photoplethysmography method, based on a tissue-like model of the skin, that allows accurate measurement of heart rate and heart rate variability parameters. The error in heart rate estimates is equivalent to state-of-the-art techniques and computation is much faster.

  11. Ride comfort analysis with physiological parameters for an e-health train.

    PubMed

    Lee, Youngbum; Shin, Kwangsoo; Lee, Sangjoon; Song, Yongsoo; Han, Sungho; Lee, Myoungho

    2009-12-01

    Transportation by train has numerous advantages over road transportation, especially with regard to energy efficiency, ecological features, safety, and punctuality. However, the contrast in ride comfort between standard road transportation and train travel has become a competitive issue. The ride comfort enhancement technology of tilting trains (TTX) is a particularly important issue in the development of the Korean high-speed railroad business. Ride comfort is now defined in international standards such as UIC13 and ISO2631. The Korean standards such as KSR9216 mainly address physical parameters such as vibration and noise. In the area of ride comfort, living quality parameter techniques have recently been considered in Korea, Japan, and Europe. This study introduces biological parameters, particularly variations in heart rate, as a more direct measure of comfort. Biological parameters are based on physiological responses rather than on purely external mechanical parameters. Variability of heart rate and other physiological parameters of passengers are measured in a simulation involving changes in the tilting angle of the TTX. This research is a preliminary study for the implementation of an e-health train, which would provide passengers with optimized ride comfort. The e-health train would also provide feedback on altered ride comfort situations that can improve a passenger's experience and provide a healthcare service on the train. The aim of this research was to develop a ride comfort evaluation system for the railway industry, the automobile industry, and the air industry. The degree of tilt correlated with heart rate, fatigue, and unrelieved alertness.

  12. Flow dynamics and energy efficiency of flow in the left ventricle during myocardial infarction.

    PubMed

    Vasudevan, Vivek; Low, Adriel Jia Jun; Annamalai, Sarayu Parimal; Sampath, Smita; Poh, Kian Keong; Totman, Teresa; Mazlan, Muhammad; Croft, Grace; Richards, A Mark; de Kleijn, Dominique P V; Chin, Chih-Liang; Yap, Choon Hwai

    2017-10-01

    Cardiovascular disease is a leading cause of death worldwide, where myocardial infarction (MI) is a major category. After infarction, the heart has difficulty providing sufficient energy for circulation, and thus, understanding the heart's energy efficiency is important. We induced MI in a porcine animal model via circumflex ligation and acquired multiple-slice cine magnetic resonance (MR) images in a longitudinal manner-before infarction, and 1 week (acute) and 4 weeks (chronic) after infarction. Computational fluid dynamic simulations were performed based on MR images to obtain detailed fluid dynamics and energy dynamics of the left ventricles. Results showed that energy efficiency flow through the heart decreased at the acute time point. Since the heart was observed to experience changes in heart rate, stroke volume and chamber size over the two post-infarction time points, simulations were performed to test the effect of each of the three parameters. Increasing heart rate and stroke volume were found to significantly decrease flow energy efficiency, but the effect of chamber size was inconsistent. Strong complex interplay was observed between the three parameters, necessitating the use of non-dimensional parameterization to characterize flow energy efficiency. The ratio of Reynolds to Strouhal number, which is a form of Womersley number, was found to be the most effective non-dimensional parameter to represent energy efficiency of flow in the heart. We believe that this non-dimensional number can be computed for clinical cases via ultrasound and hypothesize that it can serve as a biomarker for clinical evaluations.

  13. Evaluation of the metabolic rate based on the recording of the heart rate.

    PubMed

    Malchaire, Jacques; d'AMBROSIO Alfano, Francesca Romana; Palella, Boris Igor

    2017-06-08

    The assessment of harsh working conditions requires a correct evaluation of the metabolic rate. This paper revises the basis described in the ISO 8996 standard for the evaluation of the metabolic rate at a work station from the recording of the heart rate of a worker during a representative period of time. From a review of the literature, formulas different from those given in the standard are proposed to estimate the maximum working capacity, the maximum heart rate, the heart rate and the metabolic rate at rest and the relation (HR vs. M) at the basis of the estimation of the equivalent metabolic rate, as a function of the age, height and weight of the person. A Monte Carlo simulation is used to determine, from the approximations of these parameters and formulas, the imprecision of the estimated equivalent metabolic rate. The results show that the standard deviation of this estimate varies from 10 to 15%.

  14. Evaluation of the metabolic rate based on the recording of the heart rate

    PubMed Central

    MALCHAIRE, Jacques; ALFANO, Francesca Romana d’AMBROSIO; PALELLA, Boris Igor

    2017-01-01

    The assessment of harsh working conditions requires a correct evaluation of the metabolic rate. This paper revises the basis described in the ISO 8996 standard for the evaluation of the metabolic rate at a work station from the recording of the heart rate of a worker during a representative period of time. From a review of the literature, formulas different from those given in the standard are proposed to estimate the maximum working capacity, the maximum heart rate, the heart rate and the metabolic rate at rest and the relation (HR vs. M) at the basis of the estimation of the equivalent metabolic rate, as a function of the age, height and weight of the person. A Monte Carlo simulation is used to determine, from the approximations of these parameters and formulas, the imprecision of the estimated equivalent metabolic rate. The results show that the standard deviation of this estimate varies from 10 to 15%. PMID:28250334

  15. Heart-rate variability depression in porcine peritonitis-induced sepsis without organ failure.

    PubMed

    Jarkovska, Dagmar; Valesova, Lenka; Chvojka, Jiri; Benes, Jan; Danihel, Vojtech; Sviglerova, Jitka; Nalos, Lukas; Matejovic, Martin; Stengl, Milan

    2017-05-01

    Depression of heart-rate variability (HRV) in conditions of systemic inflammation has been shown in both patients and experimental animal models and HRV has been suggested as an early indicator of sepsis. The sensitivity of HRV-derived parameters to the severity of sepsis, however, remains unclear. In this study we modified the clinically relevant porcine model of peritonitis-induced sepsis in order to avoid the development of organ failure and to test the sensitivity of HRV to such non-severe conditions. In 11 anesthetized, mechanically ventilated and instrumented domestic pigs of both sexes, sepsis was induced by fecal peritonitis. The dose of feces was adjusted and antibiotic therapy was administered to avoid multiorgan failure. Experimental subjects were screened for 40 h from the induction of sepsis. In all septic animals, sepsis with hyperdynamic circulation and increased plasma levels of inflammatory mediators developed within 12 h from the induction of peritonitis. The sepsis did not progress to multiorgan failure and there was no spontaneous death during the experiment despite a modest requirement for vasopressor therapy in most animals (9/11). A pronounced reduction of HRV and elevation of heart rate developed quickly (within 5 h, time constant of 1.97 ± 0.80 h for HRV parameter TINN) upon the induction of sepsis and were maintained throughout the experiment. The frequency domain analysis revealed a decrease in the high-frequency component. The reduction of HRV parameters and elevation of heart rate preceded sepsis-associated hemodynamic changes by several hours (time constant of 11.28 ± 2.07 h for systemic vascular resistance decline). A pronounced and fast reduction of HRV occurred in the setting of a moderate experimental porcine sepsis without organ failure. Inhibition of parasympathetic cardiac signaling probably represents the main mechanism of HRV reduction in sepsis. The sensitivity of HRV to systemic inflammation may allow early detection of a moderate sepsis without organ failure. Impact statement A pronounced and fast reduction of heart-rate variability occurred in the setting of a moderate experimental porcine sepsis without organ failure. Dominant reduction of heart-rate variability was found in the high-frequency band indicating inhibition of parasympathetic cardiac signaling as the main mechanism of heart-rate variability reduction. The sensitivity of heart-rate variability to systemic inflammation may contribute to an early detection of moderate sepsis without organ failure.

  16. Frequency characteristics of the heart rate variability produced by Cheyne-Stokes respiration during 24-hr ambulatory electrocardiographic monitoring.

    PubMed

    Ichimaru, Y; Yanaga, T

    1989-06-01

    Spectral analysis of heart rates during 24-hr ambulatory electrocardiographic monitoring has been carried out to characterize the heart rate spectral components of Cheyne-Stokes respiration (CSR) by using fast Fourier transformation (FFT). Eight patients with congestive heart failure were selected for the study. FFT analyses have been performed for 614.4 sec. Out of the power spectrum, five parameters were extracted to characterize the CSR. The low peak frequencies in eight subjects were between 0.0179 Hz (56 sec) and 0.0081 Hz (123 sec). The algorithms used to detect CSR are the followings: (i) if the LFPA/ULFA ratios were above the absolute value of 1.0, and (ii) the LFPP/MLFP ratios were above the absolute values of 4.0, then the power spectrum is suggestive of CSR. We conclude that the automatic detection of CSR by heart rate spectral analysis during ambulatory ECG monitoring may afford a tool for the evaluation of the patients with congestive heart failure.

  17. Modeling and quantification of repolarization feature dependency on heart rate.

    PubMed

    Minchole, A; Zacur, E; Pueyo, E; Laguna, P

    2014-01-01

    This article is part of the Focus Theme of Methods of Information in Medicine on "Biosignal Interpretation: Advanced Methods for Studying Cardiovascular and Respiratory Systems". This work aims at providing an efficient method to estimate the parameters of a non linear model including memory, previously proposed to characterize rate adaptation of repolarization indices. The physiological restrictions on the model parameters have been included in the cost function in such a way that unconstrained optimization techniques such as descent optimization methods can be used for parameter estimation. The proposed method has been evaluated on electrocardiogram (ECG) recordings of healthy subjects performing a tilt test, where rate adaptation of QT and Tpeak-to-Tend (Tpe) intervals has been characterized. The proposed strategy results in an efficient methodology to characterize rate adaptation of repolarization features, improving the convergence time with respect to previous strategies. Moreover, Tpe interval adapts faster to changes in heart rate than the QT interval. In this work an efficient estimation of the parameters of a model aimed at characterizing rate adaptation of repolarization features has been proposed. The Tpe interval has been shown to be rate related and with a shorter memory lag than the QT interval.

  18. Heart rate, respiratory rate, apnoeas and peripheral arterial oxygen saturation in healthy term neonates during quiet sleep.

    PubMed

    Bohnhorst, B; Seidel, K; Böhne, C; Peter, C; Pirr, S

    2018-06-21

    This study compiled percentiles for cardiorespiratory parameters in healthy term neonates during quiet sleep. We enrolled 215 healthy term neonates born at Hannover Medical School, Germany, between October 2011 and March 2013. They were prospectively observed on the maternity ward at a median age of two days using six-hour recordings of pulse oximeter plethysmography, oxygen saturation, thoracic breathing movements and electrocardiogram during sleep in a supine position. We examined their heart rate, respiratory rate and oxygen saturation during quiet sleep, plus bradycardias, apnoeas lasting at least four seconds and desaturations below 85%. The third, 50 th and 97 th percentiles were calculated as follows: heart rate 87, 112 and 133 beats per minute, respiratory rate 32, 44 and 57 per minute and oxygen saturation 94, 98 and 100%. Desaturations, apnoeas and bradycardias below 80 beats per minute were common and recorded in 54%, 98% and 30% of participants. In contrast, only 7% experienced bradycardias of less than two-thirds of the baseline heart rate and 5% experienced apnoeas exceeding 15 seconds. Our results will facilitate the evidence-based valuation of cardiorespiratory parameters in term neonates and help to validate the significance of cardiorespiratory events in preterm infants at discharge. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  19. A comparison of 2 circuit exercise training techniques for eliciting matched metabolic responses in persons with paraplegia.

    PubMed

    Nash, Mark S; Jacobs, Patrick L; Woods, Jeffrey M; Clark, James E; Pray, Tanya A; Pumarejo, Alex E

    2002-02-01

    To test whether acute metabolic (VO(2)), chronotropic (heart rate), and perceptual (rating of perceived exertion; RPE) responses to exercise by persons with paraplegia differ when the exercise is on a multistation isoinertial exercise system (MultiGym) or on a customized system of Thera-Band resistance bands (ElasticGym). Within-subjects comparison of 2 treatments. Academic medical center. Sixteen men and 1 woman with complete paraplegia (T4-L1), as defined by the American Spinal Injury Association. A circuit resistance training (CRT) program for persons with paraplegia was adapted to both a MultiGym and a customized ElasticGym. Exercises used for training and testing used 6 resistance maneuvers at 50% of the 1-repetition maximum (1-RM), with interposed rapid arm spinning. Subjects were habituated to both conditions for 2 weeks before testing on randomized nonconsecutive days. VO(2) (L/min) was measured by portable spirometry, heart rate (beats/min) by a chest strap monitor, and RPE by the Borg Scale of Perceived Exertion (6-20). No significant effects of test condition on average VO(2) or heart rate were observed, with differences between conditions reflecting only .08L/min and 6.4 beats/min, respectively. Average RPE was significantly higher in testing under the ElasticGym condition (P < .05). CRT on a customized ElasticGym system elicited acute metabolic and chronotropic responses that did not differ from responses to exercise on a MultiGym, though RPE was greater with the ElasticGym. Copyright 2002 by the American Congress of Rehabilitation Medicine and the American Academy of Physical Medicine and Rehabilitation

  20. Implantation of radiotelemetry transmitters yielding data on ECG, heart rate, core body temperature and activity in free-moving laboratory mice.

    PubMed

    Cesarovic, Nikola; Jirkof, Paulin; Rettich, Andreas; Arras, Margarete

    2011-11-21

    The laboratory mouse is the animal species of choice for most biomedical research, in both the academic sphere and the pharmaceutical industry. Mice are a manageable size and relatively easy to house. These factors, together with the availability of a wealth of spontaneous and experimentally induced mutants, make laboratory mice ideally suited to a wide variety of research areas. In cardiovascular, pharmacological and toxicological research, accurate measurement of parameters relating to the circulatory system of laboratory animals is often required. Determination of heart rate, heart rate variability, and duration of PQ and QT intervals are based on electrocardiogram (ECG) recordings. However, obtaining reliable ECG curves as well as physiological data such as core body temperature in mice can be difficult using conventional measurement techniques, which require connecting sensors and lead wires to a restrained, tethered, or even anaesthetized animal. Data obtained in this fashion must be interpreted with caution, as it is well known that restraining and anesthesia can have a major artifactual influence on physiological parameters. Radiotelemetry enables data to be collected from conscious and untethered animals. Measurements can be conducted even in freely moving animals, and without requiring the investigator to be in the proximity of the animal. Thus, known sources of artifacts are avoided, and accurate and reliable measurements are assured. This methodology also reduces interanimal variability, thus reducing the number of animals used, rendering this technology the most humane method of monitoring physiological parameters in laboratory animals. Constant advancements in data acquisition technology and implant miniaturization mean that it is now possible to record physiological parameters and locomotor activity continuously and in realtime over longer periods such as hours, days or even weeks. Here, we describe a surgical technique for implantation of a commercially available telemetry transmitter used for continuous measurements of core body temperature, locomotor activity and biopotential (i.e. onelead ECG), from which heart rate, heart rate variability, and PQ and QT intervals can be established in freeroaming, untethered mice. We also present pre-operative procedures and protocols for post-operative intensive care and pain treatment that improve recovery, well-being and survival rates in implanted mice.

  1. [Evaluation of heart impact in the 100 m extreme intensity sport using near-infrared non-invasive muscle oxygen detecting device and sports heart rate detection technology].

    PubMed

    Wang, Pei-Yong; Long, Fei-Xiao; Fu, Lan-Ying; Li, Yue; Ding, Hai-Shu; Qu, An-Lian; Zhou, Xiao-Ping

    2010-02-01

    Using continuous two wavelength near-infrared technology to detect the variation in the consistency of oxygen hemoglobin in the muscle and the sports heart rate wireless real time collection technology, we devised the real time muscle tissue oxygenation and instantaneous heart rate experiment scheme and implemented it for the process of the 100 m run with two parameters given simultaneously. The experiment shows that the concentration of the oxygen hemoglobin in the muscle tissue continues decreasing after the end of the 100 m run, and the time interval between the moment when the concentration of the oxygen hemoglobin attains the minimum value and the moment when the athletes finish the 100 m run is (6.65 +/- 1.10) sec; while the heart rate continues increasing after the end of the 100 m run, and the time interval between the moment when the heart rate attains the maximum value and the moment when the athletes finish the 100 m run is (8.00 +/- 1.57) sec. The results show that the two wavelength near-infrared tissue oxygenation detection technology and the sports heart rate real time collection equipment can accurately measure the sports tissue oxygenation and the heart rate in the extreme intensity sport, and reveal the process of muscle oxygen transportation and consumption and its dynamic character with the heart rate in the extreme intensity sport.

  2. Real-time heart rate measurement for multi-people using compressive tracking

    NASA Astrophysics Data System (ADS)

    Liu, Lingling; Zhao, Yuejin; Liu, Ming; Kong, Lingqin; Dong, Liquan; Ma, Feilong; Pang, Zongguang; Cai, Zhi; Zhang, Yachu; Hua, Peng; Yuan, Ruifeng

    2017-09-01

    The rise of aging population has created a demand for inexpensive, unobtrusive, automated health care solutions. Image PhotoPlethysmoGraphy(IPPG) aids in the development of these solutions by allowing for the extraction of physiological signals from video data. However, the main deficiencies of the recent IPPG methods are non-automated, non-real-time and susceptible to motion artifacts(MA). In this paper, a real-time heart rate(HR) detection method for multiple subjects simultaneously was proposed and realized using the open computer vision(openCV) library, which consists of getting multiple subjects' facial video automatically through a Webcam, detecting the region of interest (ROI) in the video, reducing the false detection rate by our improved Adaboost algorithm, reducing the MA by our improved compress tracking(CT) algorithm, wavelet noise-suppression algorithm for denoising and multi-threads for higher detection speed. For comparison, HR was measured simultaneously using a medical pulse oximetry device for every subject during all sessions. Experimental results on a data set of 30 subjects show that the max average absolute error of heart rate estimation is less than 8 beats per minute (BPM), and the processing speed of every frame has almost reached real-time: the experiments with video recordings of ten subjects under the condition of the pixel resolution of 600× 800 pixels show that the average HR detection time of 10 subjects was about 17 frames per second (fps).

  3. Relationship Between Physiological Parameters and Acute Coronary Syndrome in Patients Presenting to the Emergency Department With Undifferentiated Chest Pain.

    PubMed

    Greenslade, Jaimi H; Beamish, Daniel; Parsonage, William; Hawkins, Tracey; Schluter, Jessica; Dalton, Emily; Parker, Kate; Than, Martin; Hammett, Christopher; Lamanna, Arvin; Cullen, Louise

    2016-01-01

    The investigators of this study sought to examine whether abnormal physiological parameters are associated with increased risk for acute coronary syndrome (ACS) in patients presenting to the emergency department (ED) with chest pain. We used prospectively collected data on adult patients presenting with suspected ACS in 2 EDs in Australia and New Zealand. Trained research nurses collected physiological data including temperature, respiratory rate, heart rate, and systolic blood pressure (SBP) on presentation to the ED. The primary endpoint was ACS within 30 days of presentation, as adjudicated by cardiologists using standardized guidelines. The prognostic utility of physiological parameters for ACS was examined using risk ratios. Acute coronary syndrome was diagnosed in 384 of the 1951 patients (20%) recruited. Compared with patients whose SBP was between 100 and 140 mm Hg, patients with an SBP of lower than 100 mm Hg or higher than 140 mm Hg were 1.4 times (95% confidence interval, 1.2-1.7) more likely to have ACS. Similarly, compared with patients whose temperature was between 36.5°C and 37.5°C, patients with temperature of lower than 36.5°C or higher than 37.5°C were 1.4 times (95% confidence interval, 1.1-1.6) more likely to have ACS. Heart rate and respiratory rate were not predictors of ACS. Patients with abnormal temperature or SBP were slightly more likely to have ACS, but such risk was of too small a magnitude to be useful in clinical decision making. Other physiological parameters (heart rate and respiratory rate) had no prognostic value. The use of physiological parameters cannot reliably confirm or rule out ACS.

  4. Assessment of post-laparotomy pain in laboratory mice by telemetric recording of heart rate and heart rate variability

    PubMed Central

    Arras, Margarete; Rettich, Andreas; Cinelli, Paolo; Kasermann, Hans P; Burki, Kurt

    2007-01-01

    Background Pain of mild to moderate grade is difficult to detect in laboratory mice because mice are prey animals that attempt to elude predators or man by hiding signs of weakness, injury or pain. In this study, we investigated the use of telemetry to identify indicators of mild-to-moderate post-laparotomy pain. Results Adult mice were subjected to laparotomy, either combined with pain treatment (carprofen or flunixin, 5 mg/kg s/c bid, for 1 day) or without pain relief. Controls received anesthesia and analgesics or vehicle only. Telemetrically measured locomotor activity was undisturbed in all animals, thus confirming that any pain experienced was of the intended mild level. No symptoms of pain were registered in any of the groups by scoring the animals' outer appearance or spontaneous and provoked behavior. In contrast, the group receiving no analgesic treatment after laparotomy demonstrated significant changes in telemetry electrocardiogram recordings: increased heart rate and decreased heart rate variability parameters pointed to sympathetic activation and pain lasting for 24 hours. In addition, core body temperature was elevated. Body weight and food intake were reduced for 3 and 2 days, respectively. Moreover, unstructured cage territory and destroyed nests appeared for 1–2 days in an increased number of animals in this group only. In controls these parameters were not affected. Conclusion In conclusion, real-time telemetric recordings of heart rate and heart rate variability were indicative of mild-to-moderate post-laparotomy pain and could define its duration in our mouse model. This level of pain cannot easily be detected by direct observation. PMID:17683523

  5. Is the normal heart rate ``chaotic'' due to respiration?

    NASA Astrophysics Data System (ADS)

    Wessel, Niels; Riedl, Maik; Kurths, Jürgen

    2009-06-01

    The incidence of cardiovascular diseases increases with the growth of the human population and an aging society, leading to very high expenses in the public health system. Therefore, it is challenging to develop sophisticated methods in order to improve medical diagnostics. The question whether the normal heart rate is chaotic or not is an attempt to elucidate the underlying mechanisms of cardiovascular dynamics and therefore a highly controversial topical challenge. In this contribution we demonstrate that linear and nonlinear parameters allow us to separate completely the data sets of the three groups provided for this controversial topic in nonlinear dynamics. The question whether these time series are chaotic or not cannot be answered satisfactorily without investigating the underlying mechanisms leading to them. We give an example of the dominant influence of respiration on heart beat dynamics, which shows that observed fluctuations can be mostly explained by respiratory modulations of heart rate and blood pressure (coefficient of determination: 96%). Therefore, we recommend reformulating the following initial question: "Is the normal heart rate chaotic?" We rather ask the following: "Is the normal heart rate `chaotic' due to respiration?"

  6. Diagnostic accuracy of heart-rate recovery after exercise in the assessment of diabetic cardiac autonomic neuropathy.

    PubMed

    Sacre, J W; Jellis, C L; Coombes, J S; Marwick, T H

    2012-09-01

    Poor prognosis associated with blunted post-exercise heart-rate recovery may reflect autonomic dysfunction. This study sought the accuracy of post-exercise heart-rate recovery in the diagnosis of cardiac autonomic neuropathy, which represents a serious, but often unrecognized complication of Type 2 diabetes. Clinical assessment of cardiac autonomic neuropathy and maximal treadmill exercise testing for heart-rate recovery were performed in 135 patients with Type 2 diabetes and negative exercise echocardiograms. Cardiac autonomic neuropathy was defined by abnormalities in ≥ 2 of 7 autonomic function markers, including four cardiac reflex tests and three indices of short-term (5-min) heart-rate variability. Heart-rate recovery was defined at 1-, 2- and 3-min post-exercise. Patients with cardiac autonomic neuropathy (n = 27; 20%) had lower heart-rate recovery at 1-, 2- and 3-min post-exercise (P < 0.01). Heart-rate recovery demonstrated univariate associations with autonomic function markers (r-values 0.20-0.46, P < 0.05). Area under the receiver-operating characteristic curve revealed good diagnostic performance of all heart-rate recovery parameters (range 0.80-0.83, P < 0.001). Optimal cut-offs for heart-rate recovery at 1-, 2- and 3-min post-exercise were ≤ 28 beats/min (sensitivity 93%, specificity 69%), ≤ 50 beats/min (sensitivity 96%, specificity 63%) and ≤ 52 beats/min (sensitivity 70%, specificity 84%), respectively. These criteria predicted cardiac autonomic neuropathy independently of relevant clinical and exercise test information (adjusted odds ratios 7-28, P < 0.05). Post-exercise heart-rate recovery provides an accurate diagnostic test for cardiac autonomic neuropathy in Type 2 diabetes. The high sensitivity and modest specificity suggests heart-rate recovery may be useful to screen for patients requiring clinical autonomic evaluation. © 2012 The Authors. Diabetic Medicine © 2012 Diabetes UK.

  7. A novel 'splice site' HCN4 Gene mutation, c.1737+1 G>T, causes familial bradycardia, reduced heart rate response, impaired chronotropic competence and increased short-term heart rate variability.

    PubMed

    Hategan, Lidia; Csányi, Beáta; Ördög, Balázs; Kákonyi, Kornél; Tringer, Annamária; Kiss, Orsolya; Orosz, Andrea; Sághy, László; Nagy, István; Hegedűs, Zoltán; Rudas, László; Széll, Márta; Varró, András; Forster, Tamás; Sepp, Róbert

    2017-08-15

    The most important molecular determinant of heart rate regulation in sino-atrial pacemaker cells includes hyperpolarization-activated, cyclic nucleotide-gated ion channels, the major isoform of which is encoded by the HCN4 gene. Mutations affecting the HCN4 gene are associated primarily with sick sinus syndrome. A novel c.1737+1 G>T 'splice-site' HCN4 mutation was identified in a large family with familial bradycardia which co-segregated with the disease providing a two-point LOD score of 4.87. Twelve out of the 22 investigated family members [4 males, 8 females average age 36 (SD 6) years] were considered as clinically affected (heart rate<60/min on resting ECG). Minimum [36 (SD 7) vs. 47 (SD 5) bpm, p=0.0087) and average heart rates [62 (SD 8) vs. 73 (SD 8) bpm, p=0.0168) were significantly lower in carriers on 24-hour Holter recordings. Under maximum exercise test carriers achieved significantly lower heart rates than non-carrier family members, and percent heart rate reserve and percent corrected heart rate reserve were significantly lower in carriers. Applying rigorous criteria for chronotropic incompetence a higher number of carriers exhibited chronotropic incompetence. Parameters, characterizing short-term variability of heart rate (i.e. rMSSD and pNN50%) were increased in carrier family members, even after normalization for heart rate, in the 24-hour ECG recordings with the same relative increase in 5-minute recordings. The identified novel 'splice site' HCN4 gene mutation, c.1737+1 G>T, causes familial bradycardia and leads to reduced heart rate response, impaired chronotropic competence and increased short-term heart rate variability in the mutation carriers. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. A randomised study of perioperative esmolol infusion for haemodynamic stability during major vascular surgery; rationale and design of DECREASE-XIII.

    PubMed

    Bakker, E J; Ravensbergen, N J; Voute, M T; Hoeks, S E; Chonchol, M; Klimek, M; Poldermans, D

    2011-09-01

    This article describes the rationale and design of the DECREASE-XIII trial, which aims to evaluate the potential of esmolol infusion, an ultra-short-acting beta-blocker, during surgery as an add-on to chronic low-dose beta-blocker therapy to maintain perioperative haemodynamic stability during major vascular surgery. A double-blind, placebo-controlled, randomised trial. A total of 260 vascular surgery patients will be randomised to esmolol or placebo as an add-on to standard medical care, including chronic low-dose beta-blockers. Esmolol is titrated to maintain a heart rate within a target window of 60-80 beats per minute for 24 h from the induction of anaesthesia. Heart rate and ischaemia are assessed by continuous 12-lead electrocardiographic monitoring for 72 h, starting 1 day prior to surgery. The primary outcome measure is duration of heart rate outside the target window during infusion of the study drug. Secondary outcome measures will be the efficacy parameters of occurrence of cardiac ischaemia, troponin T release, myocardial infarction and cardiac death within 30 days after surgery and safety parameters such as the occurrence of stroke and hypotension. This study will provide data on the efficacy of esmolol titration in chronic beta-blocker users for tight heart-rate control and reduction of ischaemia in patients undergoing vascular surgery as well as data on safety parameters. Copyright © 2011 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  9. Helicobacter pylori in sedentary men is linked to higher heart rate, sympathetic activity, and insulin resistance but not inflammation or oxidative stress

    PubMed Central

    Cherkas, Andriy; Eckl, Peter; Guéraud, Françoise; Abrahamovych, Orest; Serhiyenko, Victoria; Yatskevych, Ostap; Pliatsko, Mykhailo; Golota, Sergii

    2016-01-01

    Aim To compare anthropometric parameters, body composition, hormonal and inflammatory profiles, oxidative stress indices, and heart rate variability (HRV) in Heliobacter pylori (H.pylori) positive and negative healthy sedentary participants. Methods Among 30 recruited apparently healthy male participants (age between 20 and 40) enrolled in this cross-sectional study, 18 were H.pylori negative and 12 were positive (stool antigen test). Participants underwent routine physical examination and body composition determination. The following biochemical parameters were determined in blood: fasting whole blood glucose, glycated hemoglobin, insulin, C-peptide, cortisol, aldosterone, testosterone, thyroid stimulating hormone, C-reactive protein, interleukins 6 and 10, tumor necrosis factor-α, and the urinary level of 1,4-dihydroxynonane mercapturic acid. For HRV evaluation, electrocardiogram in supine position and in orthostatic test was performed. Results H.pylori contamination was not significantly associated with any changes in anthropometric parameters, body composition, blood pressure, fasting glucose, or glycated hemoglobin levels. No significant difference was found for inflammatory markers as well as 1,4-dihydroxynonane mercapturic acid. H.pylori-positive participants, however, had significantly higher heart rate (P = 0.009), sympathetic/parasympathetic balance in orthostatic test (P = 0.029), fasting insulin level (P = 0.037), and HOMA-index (P = 0.047). Conclusions H.pylori contamination is linked to a significantly higher heart rate, sympathetic activation, and increased insulin resistance, while inflammatory and oxidative stress markers remain unaffected in healthy sedentary male subjects. PMID:27106356

  10. A study of the effect of relaxing music on heart rate recovery after exercise among healthy students.

    PubMed

    Tan, Fuitze; Tengah, Asrin; Nee, Lo Yah; Fredericks, Salim

    2014-05-01

    Music has been employed in various clinical settings to reduce anxiety. However, meta-analysis has shown music to have little influence on haemodynamic parameters. This study aimed at investigating the effect of relaxing music on heart rate recovery after exercise. Twenty-three student volunteers underwent treadmill exercise and were assessed for heart rate recovery and saliva analysis; comparing exposure to sedative music with exposure to silence during the recovery period immediately following exercise. No differences were found between music and non-music exposure regarding: heart rate recovery, resting pulse rate, and salivary cortisol. Music was no different to silence in affecting these physiological measures, which are all associated with anxiety. Relaxing music unaccompanied by meditation techniques or other such interventions may not have a major role in reducing anxiety in certain experimental settings. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Physiological and Behavioral Parameters of Infants' Categorization: Changes in Heart Rate and Duration of Examining across Trials

    ERIC Educational Resources Information Center

    Elsner, Birgit; Pauen, Sabina; Jeschonek, Susanna

    2006-01-01

    This report investigates the relations between duration of examining and heart rate (HR) across several trials of an object-examination task. A total of N= 20 11-month-olds were familiarized with a sequence of 10 different exemplars from the same global category (animals or furniture) before they received an exemplar from the contrasting category…

  12. Assessment of cardiac autonomic functions by heart rate recovery, heart rate variability and QT dynamicity parameters in patients with acromegaly.

    PubMed

    Dural, Muhammet; Kabakcı, Giray; Cınar, Neşe; Erbaş, Tomris; Canpolat, Uğur; Gürses, Kadri Murat; Tokgözoğlu, Lale; Oto, Ali; Kaya, Ergün Barış; Yorgun, Hikmet; Sahiner, Levent; Dağdelen, Selçuk; Aytemir, Kudret

    2014-04-01

    Cardiovascular complications are the most common causes of morbidity and mortality in acromegaly. However, there is little data regarding cardiac autonomic functions in these patients. Herein, we aimed to investigate several parameters of cardiac autonomic functions in patients with acromegaly compared to healthy subjects. We enrolled 20 newly diagnosed acromegalic patients (55% female, age:45.7 ± 12.6 years) and 32 age- and gender-matched healthy subjects. All participants underwent 24 h Holter recording. Heart rate recovery (HRR) indices were calculated by subtracting 1st, 2nd and 3rd minute heart rates from maximal heart rate. All patients underwent heart rate variability (HRV) and QT dynamicity analysis. Baseline characteristics were similar except diabetes mellitus and hypertension among groups. Mean HRR1 (29.2 ± 12.3 vs 42.6 ± 6.5, p = 0.001), HRR2 (43.5 ± 15.6 vs 61.1 ± 10.8, p = 0.001) and HRR3 (46.4 ± 16.2 vs 65.8 ± 9.8, p = 0.001) values were significantly higher in control group. HRV parameters as, SDNN [standard deviation of all NN intervals] (p = 0.001), SDANN [SD of the 5 min mean RR intervals] (p = 0.001), RMSSD [root square of successive differences in RR interval] (p = 0.001), PNN50 [proportion of differences in successive NN intervals >50 ms] (p = 0.001) and high-frequency [HF] (p = 0.001) were significantly decreased in patients with acromegaly; but low frequency [LF] (p = 0.046) and LF/HF (p = 0.001) were significantly higher in acromegaly patients. QTec (p = 0.009), QTac/RR slope (p = 0.017) and QTec/RR slope (p = 0.01) were significantly higher in patients with acromegaly. Additionally, there were significant negative correlation of disease duration with HRR2, HRR3, SDNN, PNN50, RMSSD, variability index. Our study results suggest that cardiac autonomic functions are impaired in patients with acromegaly. Further large scale studies are needed to exhibit the prognostic significance of impaired autonomic functions in patients with acromegaly.

  13. Cardiac autonomic activity has a circadian rhythm in summer but not in winter in non-lactating pregnant dairy cows.

    PubMed

    Kovács, Levente; Kézér, Fruzsina Luca; Ruff, Ferenc; Szenci, Ottó

    2016-03-01

    This investigation was conducted to examine circadian and seasonal rhythms of heart rate and heart rate variability (HRV) by means of hour-by-hour recordings over 24h in a large population of non-lactating Holstein-Friesian pregnant cows [N=56, summer (June-July); N=61, winter (November-December)]. Data were collected during a 5-day period from each animal. Besides parameters of cardiac autonomic function [the high-frequency (HF) component of HRV and the ratio between the low-frequency (LF) and the HF components (LF/HF ratio)], the RR triangular index and Lmax were calculated. A clear circadian profile was observed for every parameter in summer. Heart rate elevated gradually with the course of the day from 7:00 to 17:00 o'clock and then slightly decreased from 18:00 to 6:00. Sympathovagal balance shifted towards sympathetic dominance during the daytime (increased LF/HF ratio), whereas parasympathetic activity was predominant during the night (increased HF). Lmax reflected a chaotic behavior of heart rate fluctuations during the afternoon in summer. Decreased values of RR triangular index indicated a sensitive period for cows between 14:00 and 16:00 o'clock in summer. During winter, except for the RR triangular (RRtri) index reflecting a high overall variability in R-R intervals between 12:00 and 23:00 o'clock, heart rate and HRV showed no periodicity over the 24-h period. The results suggest an impaired cardiac autonomic function during daytime in summer. HF, Lmax and RRtri index showed seasonal differences for both daytime and nighttime. Heart rate was higher in summer than in winter during the daytime, whereas the LF/HF ratio was higher in winter during the nighttime. Circadian and seasonal rhythms of cardiovascular function are presumably related to the differing temperature, and animal activity associated with summer and winter. As all of the investigated parameters are commonly used in bovine HRV research, these findings have practical implications for behavioral, physiological and welfare studies on dairy cattle. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. A mobile phone based alarm system for supervising vital parameters in free moving rats.

    PubMed

    Kellermann, Kristine; Kreuzer, Matthias; Omerovich, Adem; Hoetzinger, Franziska; Kochs, Eberhard F; Jungwirth, Bettina

    2012-02-23

    Study protocols involving experimental animals often require the monitoring of different parameters not only in anesthetized, but also in free moving animals. Most animal research involves small rodents, in which continuously monitoring parameters such as temperature and heart rate is very stressful for the awake animals or simply not possible. Aim of the underlying study was to monitor heart rate, temperature and activity and to assess inflammation in the heart, lungs, liver and kidney in the early postoperative phase after experimental cardiopulmonary bypass involving 45 min of deep hypothermic circulatory arrest in rats. Besides continuous monitoring of heart rate, temperature and behavioural activity, the main focus was on avoiding uncontrolled death of an animal in the early postoperative phase in order to harvest relevant organs before autolysis would render them unsuitable for the assessment of inflammation. We therefore set up a telemetry-based system (Data Science International, DSI™) that continuously monitored the rat's temperature, heart rate and activity in their cages. The data collection using telemetry was combined with an analysis software (Microsoft excel™), a webmail application (GMX) and a text message-service. Whenever an animal's heart rate dropped below the pre-defined threshold of 150 beats per minute (bpm), a notification in the form of a text message was automatically sent to the experimenter's mobile phone. With a positive predictive value of 93.1% and a negative predictive value of 90.5%, the designed surveillance and alarm system proved a reliable and inexpensive tool to avoid uncontrolled death in order to minimize suffering and harvest relevant organs before autolysis would set in. This combination of a telemetry-based system and software tools provided us with a reliable notification system of imminent death. The system's high positive predictive value helped to avoid uncontrolled death and facilitated timely organ harvesting. Additionally we were able to markedly reduce the drop out rate of experimental animals, and therefore the total number of animals used in our study. This system can be easily adapted to different study designs and prove a helpful tool to relieve stress and more importantly help to reduce animal numbers.

  15. [The effects of perioperative continuous administration of mivazerol on early postoperative hemodynamics and plasma catecholamines after major surgery].

    PubMed

    Apitzsch, H; Olthoff, D; Thieme, V; Vetter, B; Wiegel, M

    2000-08-01

    During and after surgical procedures a strong activation of the sympatho-adrenergic system is common with correlation to adverse cardiac outcome. Several drugs (alpha 2-adrenoceptor-agonists, beta blockers) are discussed to prevent this reaction. The new alpha 2-adrenoceptor-agonist mivazerol with marked specificity for alpha 2-adrenergic receptors may be suitable for this indication. The aim of the present study was to investigate the effects of perioperative continuous administration of mivazerol on plasma catecholamines, body temperature and calculated haemodynamic parameters in the early postoperative period in cardiac risk patients undergoing non-cardiac surgery. 36 patients with known coronary heart disease or risk factors for coronary heart disease scheduled for elective abdominal or vascular surgery were included in the study. Patients received either mivazerol (n = 18) or placebo (n = 18) [initial dose 4 micrograms kg-1 for 10 minutes before induction of anaesthesia, followed by a continuous infusion of 1.5 micrograms kg-1 h-1 intraoperatively and for as long as 72 h after surgery] in a double-blinded, randomized manner. Blood pressure, heart rate and body temperature were measured every 10 minutes until 240 minutes after arrival at the ICU. During 240 minutes after arrival at the ICU measured parameters (CVP, PAP, PCWP, SaO2, SvO2, CO), calculated parameters (CI, SVR, PVR, VO2) and plasma catecholamines were measured at defined time intervalls. The plasma concentrations of epinephrine and norepinephrine and the heart rate were significantly lower in the mivazerol group in the study period. Regarding blood pressure and body temperature there were no differences between the groups. At some measuring points preload was higher in the mivazerol group, but there were no differences between the groups for measured (SaO2, SvO2, CO) and calculated (CI, SVR, PVR, VO2) cardiorespiratory parameters. The incidence of shivering, nausea and vomiting were similar in both groups. Continuous, perioperative administration of mivazerol decreased the heart rate and the plasma catecholamines in the early postoperative period, but did not affect blood pressure, body temperature and the incidence of shivering. There were also no effects of mivazerol on calculated haemodynamic parameters (CO, SVR, PVR, VO2). These findings show a selective decrease in heart rate by Mivazerol without markedly cardiorespiratory side effects.

  16. Heart rate turbulence predicts ICD-resistant mortality in ischaemic heart disease.

    PubMed

    Marynissen, Thomas; Floré, Vincent; Heidbuchel, Hein; Nuyens, Dieter; Ector, Joris; Willems, Rik

    2014-07-01

    In high-risk patients, implantable cardioverter-defibrillators (ICDs) can convert the mode of death from arrhythmic to pump failure death. Therefore, we introduced the concept of 'ICD-resistant mortality' (IRM), defined as death (a) without previous appropriate ICD intervention (AI), (b) within 1 month after the first AI, or (c) within 1 year after the initial ICD implantation. Implantable cardioverter-defibrillator implantation in patients with a high risk of IRM should be avoided. Implantable cardioverter-defibrillator patients with ischaemic heart disease were included if a digitized 24 h Holter was available pre-implantation. Demographic, electrocardiographic, echocardiographic, and 24 h Holter risk factors were collected at device implantation. The primary endpoint was IRM. Cox regression analyses were used to test the association between predictors and outcome. We included 130 patients, with a mean left ventricular ejection fraction (LVEF) of 33.6 ± 10.3%. During a follow-up of 52 ± 31 months, 33 patients died. There were 21 cases of IRM. Heart rate turbulence (HRT) was the only Holter parameter associated with IRM and total mortality. A higher New York Heart Association (NYHA) class and a lower body mass index were the strongest predictors of IRM. Left ventricular ejection fraction predicted IRM on univariate analysis, and was the strongest predictor of total mortality. The only parameter that predicted AI was non-sustained ventricular tachycardia. Implantable cardioverter-defibrillator implantation based on NYHA class and LVEF leads to selection of patients with a higher risk of IRM and death. Heart rate turbulence may have added value for the identification of poor candidates for ICD therapy. Available Holter parameters seem limited in their ability to predict AI. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2013. For permissions please email: journals.permissions@oup.com.

  17. Uncertainty analysis of multi-rate kinetics of uranium desorption from sediments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Xiaoying; Liu, Chongxuan; Hu, Bill X.

    2014-01-01

    A multi-rate expression for uranyl [U(VI)] surface complexation reactions has been proposed to describe diffusion-limited U(VI) sorption/desorption in heterogeneous subsurface sediments. An important assumption in the rate expression is that its rate constants follow a certain type probability distribution. In this paper, a Bayes-based, Differential Evolution Markov Chain method was used to assess the distribution assumption and to analyze parameter and model structure uncertainties. U(VI) desorption from a contaminated sediment at the US Hanford 300 Area, Washington was used as an example for detail analysis. The results indicated that: 1) the rate constants in the multi-rate expression contain uneven uncertaintiesmore » with slower rate constants having relative larger uncertainties; 2) the lognormal distribution is an effective assumption for the rate constants in the multi-rate model to simualte U(VI) desorption; 3) however, long-term prediction and its uncertainty may be significantly biased by the lognormal assumption for the smaller rate constants; and 4) both parameter and model structure uncertainties can affect the extrapolation of the multi-rate model with a larger uncertainty from the model structure. The results provide important insights into the factors contributing to the uncertainties of the multi-rate expression commonly used to describe the diffusion or mixing-limited sorption/desorption of both organic and inorganic contaminants in subsurface sediments.« less

  18. Gaussian Mixture Model of Heart Rate Variability

    PubMed Central

    Costa, Tommaso; Boccignone, Giuseppe; Ferraro, Mario

    2012-01-01

    Heart rate variability (HRV) is an important measure of sympathetic and parasympathetic functions of the autonomic nervous system and a key indicator of cardiovascular condition. This paper proposes a novel method to investigate HRV, namely by modelling it as a linear combination of Gaussians. Results show that three Gaussians are enough to describe the stationary statistics of heart variability and to provide a straightforward interpretation of the HRV power spectrum. Comparisons have been made also with synthetic data generated from different physiologically based models showing the plausibility of the Gaussian mixture parameters. PMID:22666386

  19. [CARDIOREABILITATION PECULIARITIES AND CORRECTION OF VIOLATIONS OF SISTOLIC, DIASOLIC FUNCTION AND HEART RATE VARIABILITY IN PATIENTS WITH ACUTE CORONARY SYNDROME AND CORONARY ARTERY REVASCULARIZATION].

    PubMed

    Shved, M; Tsuglevych, L; Kyrychok, I; Levytska, L; Boiko, T; Kitsak, Ya

    2017-04-01

    In patients with acute coronary syndrome (ACS) who underwent coronary arteries revascularization, violations of hemodynamics, metabolism and heart rate variability often develop in the postoperative period, therefore, the goal of the study was to establish the features of disturbances and the effectiveness of correction of left ventricular systolic and diastolic dysfunction and heart rate variability in stages of cardiorehabilitation in patients with acute coronary syndrome who underwent coronary arteries revascularization. The experimental group included 40 patients with ACS in the postoperative period who underwent balloon angioplasty and stenting of the coronary arteries (25 patients with ST-segment elevation ACS and 15 patients without ST-segment elevation ACS). The age of examined patients was 37 to 74 years, an average of 52.6±6.7 years. The control group consisted of 20 patients, comparable in age and clinico-laboratory manifestations of ACS, who underwent drug treatment with direct anticoagulants, double antiplatelet therapy, β-blockers, ACE inhibitors and statins. Clinical efficacy of cardiorespiratory process in patients of both groups was assessed by the dynamics of general clinical symptoms and parameters of natriuretic propeptide, systolic and diastolic function of the left ventricle and heart rate variability. In the initial state, clinical and laboratory-instrumental signs of myocardial ischemia disappear in patients with ACS undergoing surgical revascularization of the coronary arteries, but clinical and subclinical manifestations of heart failure were diagnosed. The use of the accelerated program of cardiac rehabilitation already during the first month of studies leads to a decreasement of the signs of systolic and diastolic dysfunction, the level of NT-proBNP and improve in the variability of the heart rhythm wich significantly improves the life quality of patients with ACS. To monitor the effectiveness and safety of cardiac rehabilitation in patients with ACS who underwent coronary arteries revascularization, in addition to the generally accepted methods (determination of heart rate, blood pressure, a 6-minute test), it is advisable to diagnose the subclinical stage of heart failure by determining the level of NT-proBNP, Doppler echocardiogram, parameters of the left ventricular systolic and diastolic function and heart rate variability.

  20. Representativeness comparisons of nurse and computer charting of heart rate across nursing-intensity protocols.

    PubMed

    Luna, Jorge M; Yip, Natalie; Pivovarov, Rimma; Vawdrey, David K

    2016-08-01

    Clinical teams in acute inpatient settings can greatly benefit from automated charting technologies that continuously monitor patient vital status. NewYork-Presbyterian has designed and developed a real-time patient monitoring system that integrates vital signs sensors, networking, and electronic health records, to allow for automatic charting of patient status. We evaluate the representativeness (a combination of agreement, safety and timing) of a core vital sign across nursing intensity care protocols for preliminary feasibility assessment. Our findings suggest an automated way of summarizing heart rate provides representation of true heart rate status and can facilitate alternatives approaches to burdensome manual nurse charting of physiological parameters.

  1. Comparison of three methods to identify the anaerobic threshold during maximal exercise testing in patients with chronic heart failure.

    PubMed

    Beckers, Paul J; Possemiers, Nadine M; Van Craenenbroeck, Emeline M; Van Berendoncks, An M; Wuyts, Kurt; Vrints, Christiaan J; Conraads, Viviane M

    2012-02-01

    Exercise training efficiently improves peak oxygen uptake (V˙O2peak) in patients with chronic heart failure. To optimize training-derived benefit, higher exercise intensities are being explored. The correct identification of anaerobic threshold is important to allow safe and effective exercise prescription. During 48 cardiopulmonary exercise tests obtained in patients with chronic heart failure (59.6 ± 11 yrs; left ventricular ejection fraction, 27.9% ± 9%), ventilatory gas analysis findings and lactate measurements were collected. Three technicians independently determined the respiratory compensation point (RCP), the heart rate turning point (HRTP) and the second lactate turning point (LTP2). Thereafter, exercise intensity (target heart rate and workload) was calculated and compared between the three methods applied. Patients had significantly reduced maximal exercise capacity (68% ± 21% of predicted V˙O2peak) and chronotropic incompetence (74% ± 7% of predicted peak heart rate). Heart rate, workload, and V˙O2 at HRTP and at RCP were not different, but at LTP2, these parameters were significantly (P < 0.0001) higher. Mean target heart rate and target workload calculated using the LTP2 were 5% and 12% higher compared with those calculated using HRTP and RCP, respectively. The calculation of target heart rate based on LTP2 was 5% and 10% higher in 12 of 48 (25%) and 6 of 48 (12.5%) patients, respectively, compared with the other two methods. In patients with chronic heart failure, RCP and HRTP, determined during cardiopulmonary exercise tests, precede the occurrence of LTP2. Target heart rates and workloads used to prescribe tailored exercise training in patients with chronic heart failure based on LTP2 are significantly higher than those derived from HRTP and RCP.

  2. Music therapy, emotions and the heart: a pilot study.

    PubMed

    Raglio, Alfredo; Oasi, Osmano; Gianotti, Marta; Bellandi, Daniele; Manzoni, Veronica; Goulene, Karine; Imbriani, Chiara; Badiale, Marco Stramba

    2012-01-01

    The autonomic nervous system plays an important role in the control of cardiac function. It has been suggested that sound and music may have effects on the autonomic control of the heart inducing emotions, concomitantly with the activation of specific brain areas, i.e. the limbic area, and they may exert potential beneficial effects. This study is a prerequisite and defines a methodology to assess the relation between changes in cardiac physiological parameters such as heart rate, QT interval and their variability and the psychological responses to music therapy sessions. We assessed the cardiac physiological parameters and psychological responses to a music therapy session. ECG Holter recordings were performed before, during and after a music therapy session in 8 healthy individuals. The different behaviors of the music therapist and of the subjects have been analyzed with a specific music therapy assessment (Music Therapy Checklist). After the session mean heart rate decreased (p = 0.05), high frequency of heart rate variability tended to be higher and QTc variability tended to be lower. During music therapy session "affect attunements" have been found in all subjects but one. A significant emotional activation was associated to a higher dynamicity and variations of sound-music interactions. Our results may represent the rational basis for larger studies in diferent clinical conditions.

  3. Improved format for radiocardiographic data

    NASA Technical Reports Server (NTRS)

    Dimeff, J.; Sevelius, G.

    1973-01-01

    Technique involves introduction of radioactive sample into antecubital vein. Scintillation crystal mounted in collimating housing views portion of right and left hearts. As radioactive sample passes through heart, counting rate is measured by crystal and recorded on strip chart. Data is insensitive to geometric effects and other parameters.

  4. The application of information theory for the research of aging and aging-related diseases.

    PubMed

    Blokh, David; Stambler, Ilia

    2017-10-01

    This article reviews the application of information-theoretical analysis, employing measures of entropy and mutual information, for the study of aging and aging-related diseases. The research of aging and aging-related diseases is particularly suitable for the application of information theory methods, as aging processes and related diseases are multi-parametric, with continuous parameters coexisting alongside discrete parameters, and with the relations between the parameters being as a rule non-linear. Information theory provides unique analytical capabilities for the solution of such problems, with unique advantages over common linear biostatistics. Among the age-related diseases, information theory has been used in the study of neurodegenerative diseases (particularly using EEG time series for diagnosis and prediction), cancer (particularly for establishing individual and combined cancer biomarkers), diabetes (mainly utilizing mutual information to characterize the diseased and aging states), and heart disease (mainly for the analysis of heart rate variability). Few works have employed information theory for the analysis of general aging processes and frailty, as underlying determinants and possible early preclinical diagnostic measures for aging-related diseases. Generally, the use of information-theoretical analysis permits not only establishing the (non-linear) correlations between diagnostic or therapeutic parameters of interest, but may also provide a theoretical insight into the nature of aging and related diseases by establishing the measures of variability, adaptation, regulation or homeostasis, within a system of interest. It may be hoped that the increased use of such measures in research may considerably increase diagnostic and therapeutic capabilities and the fundamental theoretical mathematical understanding of aging and disease. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. [The effectiveness of romifidine on myocardial function in horses with and without heart disease, evaluated with M-mode echocardiography and PW-tissue Doppler imaging].

    PubMed

    Nagel, Deborah; Gehlen, Heidrun

    2013-01-01

    The aim of this study was to evaluate to what extent the myocardial function in horses (measured by PW-tissue Doppler = PW-TDI) is affected during a sedation with romifidine (0.04 mg/kg, i. v.), particularly in case of an accompanying heart disease. Based on an echo- and electrocardiographic examination, a total of 45 horses was subdivided into group 1 (no heart disease), group 2 (heart disease without increased heart dimensions) and group 3 (heart disease with increased heart dimensions). Heart rate (HF), M-mode- (FS%) and TDI-measurements were performed before and after the application of romifidine. The velocities of the radial myocardial movement in the left and right ventricular wall were evaluated using PW-TDI. The TDI parameters included the isovolumic contraction (IVC), the systolic (S) as well as the early (E) and late diastolic maximal velocity (A). After the application of romifidine HF and FS were significantly decreased in all groups. IVC, S and E, determined by PW-TDI were also significantly decreased in both ventricular walls. A significant difference between groups was shown for the isovolumic contraction in the left ventricular wall. This was observed distinctly more in horses with heart disease and increased heart dimensions compared to horses with heart disease but no increased heart dimensions. The results of the study indicate that PW-TDI is a suitable imaging technique to analyse the effects of romifidine on equine myocardial function. The major percentage change after application of romifidine for TDI measurements compared to the M-mode parameters indicate that the parameter myocardial velocity measured with TDI appeared to be the most sensitive parameter to document romifidine--induced changes on the myocardium.

  6. Bio-logging of physiological parameters in higher marine vertebrates

    NASA Astrophysics Data System (ADS)

    Ponganis, Paul J.

    2007-02-01

    Bio-logging of physiological parameters in higher marine vertebrates had its origins in the field of bio-telemetry in the 1960s and 1970s. The development of microprocessor technology allowed its first application to bio-logging investigations of Weddell seal diving physiology in the early 1980s. Since that time, with the use of increased memory capacity, new sensor technology, and novel data processing techniques, investigators have examined heart rate, temperature, swim speed, stroke frequency, stomach function (gastric pH and motility), heat flux, muscle oxygenation, respiratory rate, diving air volume, and oxygen partial pressure (P) during diving. Swim speed, heart rate, and body temperature have been the most commonly studied parameters. Bio-logging investigation of pressure effects has only been conducted with the use of blood samplers and nitrogen analyses on animals diving at isolated dive holes. The advantages/disadvantages and limitations of recording techniques, probe placement, calibration techniques, and study conditions are reviewed.

  7. The Effect of Manual Restraint on Physiological Parameters in Barred Owls ( Strix varia ).

    PubMed

    Doss, Grayson A; Mans, Christoph

    2017-03-01

    Manual restraint is commonly necessary when working with avian species in medical, laboratory, and field settings. Despite their prevalence, little is known about the stress response in raptorial bird species. To further understand the effect of restraint on the stress response in birds of prey, 12 barred owls ( Strix varia ) were manually restrained for 15 minutes. Physiological parameters (cloacal temperature, respiratory rate, heart rate) were followed over time and recorded at defined points during the restraint period. Heart rate decreased significantly over the restraint period by a mean ± SD of -73 ± 46 beats/min. Respiratory rate also decreased significantly (median: -11 breaths/min, interquartile range: -8 to -18). Cloacal temperature increased significantly over time in manually restrained owls (median: +1.5°C [+2.7°F], interquartile range: 1.3°C-2.1°C [2.3°F-3.8°F]). This study is the first to document stress hyperthermia in an owl species. Similar to another raptorial bird, the red-tailed hawk ( Buteo jamaicensis ), both heart rate and respiratory rate decreased and cloacal temperature increased over time in restrained barred owls. Barred owls appear to cope differently to restraint stress when compared to psittacine species.

  8. [Body composition and heart rate variability in patients with chronic obstructive pulmonary disease pulmonary rehabilitation candidates].

    PubMed

    Curilem Gatica, Cristian; Almagià Flores, Atilio; Yuing Farías, Tuillang; Rodríguez Rodríguez, Fernando

    2014-07-01

    Body composition is a non-invasive method, which gives us information about the distribution of tissues in the body structure, it is also an indicator of the risk of mortality in patients with chronic obstructive pulmonary disease. The heart rate variability is a technique that gives us information of autonomic physiological condition, being recognized as an indicator which is decreased in a number of diseases. The purpose of this study was to assess body composition and heart rate variability. The methodology used is that of Debora Kerr (1988) endorsed by the International Society for advances in Cineantropometría for body composition and heart rate variability of the guidelines described by the American Heart Association (1996). Roscraff equipment, caliper Slimguide and watch Polar RS 800CX was used. , BMI 26.7 ± 3.9 kg / m²; Muscle Mass 26.1 ± 6.3 kg ; Bone Mass 1.3 kg ± 8.1 76 ± 9.9 years Age : 14 candidates for pulmonary rehabilitation patients were evaluated , Adipose mass 16.4 ± 3.6 kg ; FEV1 54 ± 14%. Increased waist circumference and waist hip ratio was associated with a lower overall heart rate variability. The bone component was positively related to the variability of heart rate and patients with higher forced expiratory volume in one second had lower high frequency component in heart rate variability. In these patients, the heart rate variability is reduced globally and is associated with cardiovascular risk parameters. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  9. Visualization of Heart Rate Variability of Long-Term Heart Transplant Patient by Transition Networks: A Case Report.

    PubMed

    Wdowczyk, Joanna; Makowiec, Danuta; Dorniak, Karolina; Gruchała, Marcin

    2016-01-01

    We present a heart transplant patient at his 17th year of uncomplicated follow-up. Within a frame of routine check out several tests were performed. With such a long and uneventful follow-up some degree of graft reinnervation could be anticipated. However, the patient's electrocardiogram and exercise parameters seemed largely inconclusive in this regard. The exercise heart rate dynamics were suggestive of only mild, if any parasympathetic reinnervation of the graft with persisting sympathetic activation. On the other hand, traditional heart rate variability (HRV) indices were inadequately high, due to erratic rhythm resulting from interference of the persisting recipient sinus node or non-conducted atrial parasystole. New tools, originated from network representation of time series, by visualization short-term dynamical patterns, provided a method to discern HRV increase due to reinnervation from other reasons.

  10. Web-Based Mindfulness Intervention in Heart Disease: A Randomized Controlled Trial

    PubMed Central

    Younge, John O.; Wery, Machteld F.; Gotink, Rinske A.; Utens, Elisabeth M. W. J.; Michels, Michelle; Rizopoulos, Dimitris; van Rossum, Elisabeth F. C.

    2015-01-01

    Background Evidence is accumulating that mindfulness training has favorable effects on psychological outcomes, but studies on physiological outcomes are limited. Patients with heart disease have a high incidence of physiological and psychological problems and may benefit from mindfulness training. Our aim was to determine the beneficial physiological and psychological effects of online mindfulness training in patients with heart disease. Methods The study was a pragmatic randomized controlled single-blind trial. Between June 2012 and April 2014 we randomized 324 patients (mean age 43.2 years, 53.7% male) with heart disease in a 2:1 ratio (n = 215 versus n = 109) to a 12-week online mindfulness training in addition to usual care (UC) compared to UC alone. The primary outcome was exercise capacity measured with the 6 minute walk test (6MWT). Secondary outcomes were other physiological parameters (heart rate, blood pressure, respiratory rate, and NT-proBNP), subjective health status (SF-36), perceived stress (PSS), psychological well-being (HADS), social support (PSSS12) and a composite endpoint (all-cause mortality, heart failure, symptomatic arrhythmia, cardiac surgery, and percutaneous cardiac intervention). Linear mixed models were used to evaluate differences between groups on the repeated outcome measures. Results Compared to UC, mindfulness showed a borderline significant improved 6MWT (effect size, meters: 13.2, 95%CI: -0.02; 26.4, p = 0.050). There was also a significant lower heart rate in favor of the mindfulness group (effect size, beats per minute: -2.8, 95%CI: -5.4;-0.2, p = 0.033). No significant differences were seen on other outcomes. Conclusions Mindfulness training showed positive effects on the physiological parameters exercise capacity and heart rate and it might therefore be a useful adjunct to current clinical therapy in patients with heart disease. Trial Registration Dutch Trial Register 3453 PMID:26641099

  11. Pulse rate variability compared with Heart Rate Variability in children with and without sleep disordered breathing.

    PubMed

    Dehkordi, Parastoo; Garde, Ainara; Karlen, Walter; Wensley, David; Ansermino, J Mark; Dumont, Guy A

    2013-01-01

    Heart Rate Variability (HRV), the variation of time intervals between heartbeats, is one of the most promising and widely used quantitative markers of autonomic activity. Traditionally, HRV is measured as the series of instantaneous cycle intervals obtained from the electrocardiogram (ECG). In this study, we investigated the estimation of variation in heart rate from a photoplethysmography (PPG) signal, called pulse rate variability (PRV), and assessed its accuracy as an estimate of HRV in children with and without sleep disordered breathing (SDB). We recorded raw PPGs from 72 children using the Phone Oximeter, an oximeter connected to a mobile phone. Full polysomnography including ECG was simultaneously recorded for each subject. We used correlation and Bland-Altman analysis for comparing the parameters of HRV and PRV between two groups of children. Significant correlation (r > 0.90, p < 0.05) and close agreement were found between HRV and PRV for mean intervals, standard deviation of intervals (SDNN) and the root-mean square of the difference of successive intervals (RMSSD). However Bland-Altman analysis showed a large divergence for LF/HF ratio parameter. In addition, children with SDB had depressed SDNN and RMSSD and elevated LF/HF in comparison to children without SDB. In conclusion, PRV provides the accurate estimate of HRV in time domain analysis but does not reflect precise estimation for parameters in frequency domain.

  12. Effect of mobile phone radiation on heart rate variability.

    PubMed

    Ahamed, V I Thajudin; Karthick, N G; Joseph, Paul K

    2008-06-01

    The rapid increase in the use of mobile phones (MPs) in recent years has raised the problem of health risk connected with high-frequency electromagnetic fields. There are reports of headache, dizziness, numbness in the thigh, and heaviness in the chest among MP users. This paper deals with the neurological effect of electromagnetic fields radiated from MPs, by studies on heart rate variability (HRV) of 14 male volunteers. As heart rate is modulated by the autonomic nervous system, study of HRV can be used for assessing the neurological effect. The parameters used in this study for quantifying the effect on HRV are scaling exponent and sample entropy. The result indicates an increase in both the parameters when MP is kept close to the chest and a decrease when kept close to the head. MP has caused changes in HRV indices and the change varied with its position, but the changes cannot be considered significant as the p values are high.

  13. Development of sleep monitoring system for observing the effect of the room ambient toward the quality of sleep

    NASA Astrophysics Data System (ADS)

    Saad, W. H. M.; Khoo, C. W.; Rahman, S. I. Ab; Ibrahim, M. M.; Saad, N. H. M.

    2017-06-01

    Getting enough sleep at the right times can help in improving quality of life and protect mental and physical health. This study proposes a portable sleep monitoring device to determine the relationship between the room ambient and quality of sleep. Body condition parameter such as heart rate, body temperature and body movement was used to determine quality of sleep and Audio/video-based monitoring system. The functionality test on all sensors is carried out to make sure that all sensors is working properly. The functionality of the overall system is designed for a better experience with a very minimal intervention to the user. The simple test on the body condition (body temperature and heart rate) while asleep with several different ambient parameters (humidity, brightness and temperature) are varied and the result shows that someone has a better sleep in a dark and colder ambient. This can prove by lower body temperature and lower heart rate.

  14. Modeling the cardiovascular system using a nonlinear additive autoregressive model with exogenous input

    NASA Astrophysics Data System (ADS)

    Riedl, M.; Suhrbier, A.; Malberg, H.; Penzel, T.; Bretthauer, G.; Kurths, J.; Wessel, N.

    2008-07-01

    The parameters of heart rate variability and blood pressure variability have proved to be useful analytical tools in cardiovascular physics and medicine. Model-based analysis of these variabilities additionally leads to new prognostic information about mechanisms behind regulations in the cardiovascular system. In this paper, we analyze the complex interaction between heart rate, systolic blood pressure, and respiration by nonparametric fitted nonlinear additive autoregressive models with external inputs. Therefore, we consider measurements of healthy persons and patients suffering from obstructive sleep apnea syndrome (OSAS), with and without hypertension. It is shown that the proposed nonlinear models are capable of describing short-term fluctuations in heart rate as well as systolic blood pressure significantly better than similar linear ones, which confirms the assumption of nonlinear controlled heart rate and blood pressure. Furthermore, the comparison of the nonlinear and linear approaches reveals that the heart rate and blood pressure variability in healthy subjects is caused by a higher level of noise as well as nonlinearity than in patients suffering from OSAS. The residue analysis points at a further source of heart rate and blood pressure variability in healthy subjects, in addition to heart rate, systolic blood pressure, and respiration. Comparison of the nonlinear models within and among the different groups of subjects suggests the ability to discriminate the cohorts that could lead to a stratification of hypertension risk in OSAS patients.

  15. Systolic blood pressure but not electrocardiogram QRS duration is associated with heart rate variability (HRV): a cross-sectional study in rural Australian non-diabetics.

    PubMed

    Lee, Yvonne Yin Leng; Jelinek, Herbert F; McLachlan, Craig S

    2017-01-01

    A positive correlation between ECG derived QRS duration and heart rate variability (HRV) parameters had previously been reported in young healthy adults. We note this study used a narrow QRS duration range, and did not adjust for systolic blood pressure. Our aims are to investigate associations between systolic blood pressure (SBP), QRS duration and HRV in a rural aging population. A retrospective cross sectional population was obtained from the CSU Diabetes Screening Research Initiative data base where 200 participants had no diabetes or pre-diabetes. SBP data were matched with ECG derived QRS duration and HRV parameters. HRV parameters were calculated from R-R intervals. Resting 12-lead electrocardiograms were obtained from each subject using a Welch Allyn PC-Based ECG system. Pearson correlation analysis revealed no statistically significant associations between HRV parameters and QRS duration. No significant mean differences in HRV parameter subgroups across defined QRS cut-offs were found. SBP > 146 mmHg was associated with increasing QRS durations, however this association disappeared once models were adjusted for age and gender. SBP was also significantly associated with a number of HRV parameters using Pearson correlation analysis, including high frequency (HF) ( p  < 0.05), HFln ( p  < 0.02), RMSDD ( p  < 0.02) and non-linear parameters; ApEN ( p  < 0.001) were negatively correlated with increasing SBP while the low frequency to high frequency ratio (LF/HF) increased with increasing SBP ( p  < 0.03). Our results do not support associations between ECG derived R-R derived HRV parameters and QRS duration in aging populations. We suggest that ventricular conduction as determined by QRS duration is independent of variations in SA-node heart rate variability.

  16. Stability, Consistency and Performance of Distribution Entropy in Analysing Short Length Heart Rate Variability (HRV) Signal.

    PubMed

    Karmakar, Chandan; Udhayakumar, Radhagayathri K; Li, Peng; Venkatesh, Svetha; Palaniswami, Marimuthu

    2017-01-01

    Distribution entropy ( DistEn ) is a recently developed measure of complexity that is used to analyse heart rate variability (HRV) data. Its calculation requires two input parameters-the embedding dimension m , and the number of bins M which replaces the tolerance parameter r that is used by the existing approximation entropy ( ApEn ) and sample entropy ( SampEn ) measures. The performance of DistEn can also be affected by the data length N . In our previous studies, we have analyzed stability and performance of DistEn with respect to one parameter ( m or M ) or combination of two parameters ( N and M ). However, impact of varying all the three input parameters on DistEn is not yet studied. Since DistEn is predominantly aimed at analysing short length heart rate variability (HRV) signal, it is important to comprehensively study the stability, consistency and performance of the measure using multiple case studies. In this study, we examined the impact of changing input parameters on DistEn for synthetic and physiological signals. We also compared the variations of DistEn and performance in distinguishing physiological (Elderly from Young) and pathological (Healthy from Arrhythmia) conditions with ApEn and SampEn . The results showed that DistEn values are minimally affected by the variations of input parameters compared to ApEn and SampEn. DistEn also showed the most consistent and the best performance in differentiating physiological and pathological conditions with various of input parameters among reported complexity measures. In conclusion, DistEn is found to be the best measure for analysing short length HRV time series.

  17. Visibility graph analysis of heart rate time series and bio-marker of congestive heart failure

    NASA Astrophysics Data System (ADS)

    Bhaduri, Anirban; Bhaduri, Susmita; Ghosh, Dipak

    2017-09-01

    Study of RR interval time series for Congestive Heart Failure had been an area of study with different methods including non-linear methods. In this article the cardiac dynamics of heart beat are explored in the light of complex network analysis, viz. visibility graph method. Heart beat (RR Interval) time series data taken from Physionet database [46, 47] belonging to two groups of subjects, diseased (congestive heart failure) (29 in number) and normal (54 in number) are analyzed with the technique. The overall results show that a quantitative parameter can significantly differentiate between the diseased subjects and the normal subjects as well as different stages of the disease. Further, the data when split into periods of around 1 hour each and analyzed separately, also shows the same consistent differences. This quantitative parameter obtained using the visibility graph analysis thereby can be used as a potential bio-marker as well as a subsequent alarm generation mechanism for predicting the onset of Congestive Heart Failure.

  18. Multi-objective optimization of process parameters of multi-step shaft formed with cross wedge rolling based on orthogonal test

    NASA Astrophysics Data System (ADS)

    Han, S. T.; Shu, X. D.; Shchukin, V.; Kozhevnikova, G.

    2018-06-01

    In order to achieve reasonable process parameters in forming multi-step shaft by cross wedge rolling, the research studied the rolling-forming process multi-step shaft on the DEFORM-3D finite element software. The interactive orthogonal experiment was used to study the effect of the eight parameters, the first section shrinkage rate φ1, the first forming angle α1, the first spreading angle β1, the first spreading length L1, the second section shrinkage rate φ2, the second forming angle α2, the second spreading angle β2 and the second spreading length L2, on the quality of shaft end and the microstructure uniformity. By using the fuzzy mathematics comprehensive evaluation method and the extreme difference analysis, the influence degree of the process parameters on the quality of the multi-step shaft is obtained: β2>φ2L1>α1>β1>φ1>α2L2. The results of the study can provide guidance for obtaining multi-stepped shaft with high mechanical properties and achieving near net forming without stub bar in cross wedge rolling.

  19. Effect of Stimulation of Neurotransmitter Systems on Heart Rate Variability and β-Adrenergic Responsiveness of Erythrocytes in Outbred Rats.

    PubMed

    Kur'yanova, E V; Tryasuchev, A V; Stupin, V O; Teplyi, D L

    2017-05-01

    We studied heart rate variability and β-adrenergic responsiveness of erythrocytes and changes in these parameters in response to single administration of β-adrenoblocker propranolol (2 mg/kg) in outbred male rats against the background of activation of the noradrenergic, serotonergic, and dopaminergic neurotransmitter systems achieved by 4-fold injections maprotiline (10 mg/kg), 5-hydroxytryptophan (50 mg/kg) combined with fluoxetine (3 mg/kg), and L-DOPA (20 mg/kg) with amantadine (20 mg/kg), respectively. Stimulation of the noradrenergic system moderately enhanced the heart rhythm rigidity and β-adrenergic responsiveness of erythrocytes. In addition, it markedly augmented the moderating effect of subsequently administered propranolol on LF and VLF components in the heart rate variability and reversed the effect of propranolol on β-adrenergic responsiveness of erythrocytes. Stimulation of the serotonergic system dramatically decreased all components in the heart rate variability and pronouncedly enhanced β-adrenergic responsiveness of erythrocytes. Subsequent injection of propranolol slightly restored all components in the heart rate variability and decreased β-adrenergic responsiveness of erythrocytes to the control level. Stimulation of the dopaminergic system made the heart rate more rigid due to decrease of all components in the heart rate variability; in addition, it slightly but significantly enhanced β-adrenergic responsiveness of erythrocytes. Subsequent injection of propranolol produced no significant effects on all components in the heart rate variability and on β-adrenergic responsiveness of erythrocytes. Stimulation of noradrenergic, serotonergic, and dopaminergic neurotransmitter systems produced unidirectional and consorted effects on heart rate variability and β-adrenergic responsiveness of erythrocytes, although the magnitudes of these effects were different. Probably, the changes in the heart rate variability in rats with stimulated neurotransmitter systems results from modification of the cellular sensitivity in peripheral organs to adrenergic influences. However, the differences in the reactions to β-adrenoblocker attest to specificity of the mechanisms underlying the changes in membrane reception and adrenergic pathways in every experimental model employed in this study.

  20. The Correlates of Body Composition with Heart Rate Recovery after Step Test: An Exploratory Study of Malaysian Adolescents

    PubMed Central

    Abu Hanifah, Redzal; Mohamed, Mohd. Nahar Azmi; Jaafar, Zulkarnain; Abdul Mohsein, Nabilla Al-Sadat; Jalaludin, Muhammad Yazid; Abdul Majid, Hazreen; Murray, Liam; Cantwell, Marie; Su, Tin Tin

    2013-01-01

    Background In adults, heart rate recovery is a predictor of mortality, while in adolescents it is associated with cardio-metabolic risk factors. The aim of this study was to examine the relationship between body composition measures and heart rate recovery (HRR) after step test in Malaysian secondary school students. Methods In the Malaysian Health and Adolescents Longitudinal Research Team (MyHEART) study, 1071 healthy secondary school students, aged 13 years old, participated in the step test. Parameters for body composition measures were body mass index z-score, body fat percentage, waist circumference, and waist height ratio. The step test was conducted by using a modified Harvard step test. Heart rate recovery of 1 minute (HRR1min) and heart rate recovery of 2 minutes (HRR2min) were calculated by the difference between the peak pulse rate during exercise and the resting pulse rate at 1 and 2 minutes, respectively. Analysis was done separately based on gender. Pearson correlation analysis was used to determine the association between the HRR parameters with body composition measures, while multiple regression analysis was used to determine which body composition measures was the strongest predictor for HRR. Results For both gender groups, all body composition measures were inversely correlated with HRR1min. In girls, all body composition measures were inversely correlated with HRR2min, while in boys all body composition measures, except BMI z-score, were associated with HRR2min. In multiple regression, only waist circumference was inversely associated with HRR2min (p=0.024) in boys, while in girls it was body fat percentage for HRR2min (p=0.008). Conclusion There was an inverse association between body composition measurements and HRR among apparently healthy adolescents. Therefore, it is important to identify cardio-metabolic risk factors in adolescent as an early prevention of consequent adulthood morbidity. This reiterates the importance of healthy living which should start from young. PMID:24349388

  1. Accuracy of Heart Rate Watches: Implications for Weight Management

    PubMed Central

    2016-01-01

    Background Wrist-worn monitors claim to provide accurate measures of heart rate and energy expenditure. People wishing to lose weight use these devices to monitor energy balance, however the accuracy of these devices to measure such parameters has not been established. Aim To determine the accuracy of four wrist-worn devices (Apple Watch, Fitbit Charge HR, Samsung Gear S and Mio Alpha) to measure heart rate and energy expenditure at rest and during exercise. Methods Twenty-two healthy volunteers (50% female; aged 24 ± 5.6 years) completed ~1-hr protocols involving supine and seated rest, walking and running on a treadmill and cycling on an ergometer. Data from the devices collected during the protocol were compared with reference methods: electrocardiography (heart rate) and indirect calorimetry (energy expenditure). Results None of the devices performed significantly better overall, however heart rate was consistently more accurate than energy expenditure across all four devices. Correlations between the devices and reference methods were moderate to strong for heart rate (0.67–0.95 [0.35 to 0.98]) and weak to strong for energy expenditure (0.16–0.86 [-0.25 to 0.95]). All devices underestimated both outcomes compared to reference methods. The percentage error for heart rate was small across the devices (range: 1–9%) but greater for energy expenditure (9–43%). Similarly, limits of agreement were considerably narrower for heart rate (ranging from -27.3 to 13.1 bpm) than energy expenditure (ranging from -266.7 to 65.7 kcals) across devices. Conclusion These devices accurately measure heart rate. However, estimates of energy expenditure are poor and would have implications for people using these devices for weight loss. PMID:27232714

  2. Accuracy of Heart Rate Watches: Implications for Weight Management.

    PubMed

    Wallen, Matthew P; Gomersall, Sjaan R; Keating, Shelley E; Wisløff, Ulrik; Coombes, Jeff S

    2016-01-01

    Wrist-worn monitors claim to provide accurate measures of heart rate and energy expenditure. People wishing to lose weight use these devices to monitor energy balance, however the accuracy of these devices to measure such parameters has not been established. To determine the accuracy of four wrist-worn devices (Apple Watch, Fitbit Charge HR, Samsung Gear S and Mio Alpha) to measure heart rate and energy expenditure at rest and during exercise. Twenty-two healthy volunteers (50% female; aged 24 ± 5.6 years) completed ~1-hr protocols involving supine and seated rest, walking and running on a treadmill and cycling on an ergometer. Data from the devices collected during the protocol were compared with reference methods: electrocardiography (heart rate) and indirect calorimetry (energy expenditure). None of the devices performed significantly better overall, however heart rate was consistently more accurate than energy expenditure across all four devices. Correlations between the devices and reference methods were moderate to strong for heart rate (0.67-0.95 [0.35 to 0.98]) and weak to strong for energy expenditure (0.16-0.86 [-0.25 to 0.95]). All devices underestimated both outcomes compared to reference methods. The percentage error for heart rate was small across the devices (range: 1-9%) but greater for energy expenditure (9-43%). Similarly, limits of agreement were considerably narrower for heart rate (ranging from -27.3 to 13.1 bpm) than energy expenditure (ranging from -266.7 to 65.7 kcals) across devices. These devices accurately measure heart rate. However, estimates of energy expenditure are poor and would have implications for people using these devices for weight loss.

  3. Application of dragonfly algorithm for optimal performance analysis of process parameters in turn-mill operations- A case study

    NASA Astrophysics Data System (ADS)

    Vikram, K. Arun; Ratnam, Ch; Lakshmi, VVK; Kumar, A. Sunny; Ramakanth, RT

    2018-02-01

    Meta-heuristic multi-response optimization methods are widely in use to solve multi-objective problems to obtain Pareto optimal solutions during optimization. This work focuses on optimal multi-response evaluation of process parameters in generating responses like surface roughness (Ra), surface hardness (H) and tool vibration displacement amplitude (Vib) while performing operations like tangential and orthogonal turn-mill processes on A-axis Computer Numerical Control vertical milling center. Process parameters like tool speed, feed rate and depth of cut are considered as process parameters machined over brass material under dry condition with high speed steel end milling cutters using Taguchi design of experiments (DOE). Meta-heuristic like Dragonfly algorithm is used to optimize the multi-objectives like ‘Ra’, ‘H’ and ‘Vib’ to identify the optimal multi-response process parameters combination. Later, the results thus obtained from multi-objective dragonfly algorithm (MODA) are compared with another multi-response optimization technique Viz. Grey relational analysis (GRA).

  4. Effect of music on postoperative pain and physiologic parameters of patients after open heart surgery.

    PubMed

    Özer, Nadiye; Karaman Özlü, Zeynep; Arslan, Sevban; Günes, Nezihat

    2013-03-01

    The aim of this study was to investigate the effect of listening to personal choice of music on self-report of pain intensity and the physiologic parameters in patients who have undergone open heart surgery. The study design was quasiexperimental. Patients were selected through convenience sampling in the Cardiovascular Surgery Intensive Care Unit at a university hospital. The study was conducted with a total of 87 patients who underwent open heart surgery: 44 in the music group, 43 in the control group, ages between 18 and 78 years. Through pretest-posttest design, postoperative first-day data were collected. First, physiologic parameters (blood pressure, heart rate, oxygen saturation, and respiratory rate) were recorded and a unidimensional verbal pain intensity scale applied to all participants. Later, the control group had a rest in their beds while the music group listened to their choice of music for 30 minutes. Physiologic data were then collected and the pain intensity scale applied once more. In the music group, there was a statistically significant increase in oxygen saturation (p = .001) and a lower pain score (p = .001) than in the control group. There was no difference between the groups in the other physiologic parameters. Results of this research provide evidence to support the use of music. Music might be a simple, safe, and effective method of reducing potentially harmful physiologic responses arising from pain in patients after open heart surgery. Copyright © 2013 American Society for Pain Management Nursing. Published by Elsevier Inc. All rights reserved.

  5. Impact of space weather on human heart rate during the years 2011-2013

    NASA Astrophysics Data System (ADS)

    Galata, E.; Ioannidou, S.; Papailiou, M.; Mavromichalaki, H.; Paravolidakis, K.; Kouremeti, M.; Rentifis, L.; Simantirakis, E.; Trachanas, K.

    2017-08-01

    During the last years a possible link between different levels of solar and geomagnetic disturbances and human physiological parameters is suggested by several published studies. In this work the examination of the potential association between heart rate variations and specific space weather activities was performed. A total of 482 individuals treated at Hippocratio General Hospital in Athens, the Cardiology clinics of Nikaia General Hospital in Piraeus and the Heraklion University Hospital in Crete, Greece, were assessed from July 2011 to April 2013. The heart rate of the individuals was recorded by a Holter monitor on a n hourly basis, while the hourly variations of the cosmic ray intensity measured by the Neutron Monitor Station of the Athens University and of the geomagnetic index Dst provided by the Kyoto Observatory were used. The ANalysis Of VAriance (ANOVA) and the Multiple Linear Regression analysis were used for analysis of these data. A statistically significant effect of both cosmic rays and geomagnetic activity on heart rate was observed, which may indicate that changes in space weather could be linked to heart rate variations.

  6. Measurement of the main and critical parameters for optimal laser treatment of heart disease

    NASA Astrophysics Data System (ADS)

    Kabeya, FB; Abrahamse, H.; Karsten, AE

    2017-10-01

    Laser light is frequently used in the diagnosis and treatment of patients. As in traditional treatments such as medication, bypass surgery, and minimally invasive ways, laser treatment can also fail and present serious side effects. The true reason for laser treatment failure or the side effects thereof, remains unknown. From the literature review conducted, and experimental results generated we conclude that an optimal laser treatment for coronary artery disease (named heart disease) can be obtained if certain critical parameters are correctly measured and understood. These parameters include the laser power, the laser beam profile, the fluence rate, the treatment time, as well as the absorption and scattering coefficients of the target treatment tissue. Therefore, this paper proposes different, accurate methods for the measurement of these critical parameters to determine the optimal laser treatment of heart disease with a minimal risk of side effects. The results from the measurement of absorption and scattering properties can be used in a computer simulation package to predict the fluence rate. The computing technique is a program based on the random number (Monte Carlo) process and probability statistics to track the propagation of photons through a biological tissue.

  7. Study of Heart Rate Variability in Bipolar Disorder: Linear and Non-Linear Parameters during Sleep

    PubMed Central

    Migliorini, Matteo; Mendez, Martin O.; Bianchi, Anna M.

    2012-01-01

    The aim of the study is to define physiological parameters and vital signs that may be related to the mood and mental status in patients affected by bipolar disorder. In particular we explored the autonomic nervous system through the analysis of the heart rate variability. Many different parameters, in the time and in the frequency domain, linear and non-linear were evaluated during the sleep in a group of normal subject and in one patient in four different conditions. The recording of the signals was performed through a wearable sensorized T-shirt. Heart rate variability (HRV) signal and movement analysis allowed also obtaining sleep staging and the estimation of REM sleep percentage over the total sleep time. A group of eight normal females constituted the control group, on which normality ranges were estimated. The pathologic subject was recorded during four different nights, at time intervals of at least 1 week, and during different phases of the disturbance. Some of the examined parameters (MEANNN, SDNN, RMSSD) confirmed reduced HRV in depression and bipolar disorder. REM sleep percentage was found to be increased. Lempel–Ziv complexity and sample entropy, on the other hand, seem to correlate with the depression level. Even if the number of examined subjects is still small, and the results need further validation, the proposed methodology and the calculated parameters seem promising tools for the monitoring of mood changes in psychiatric disorders. PMID:22291638

  8. Characteristics of cardio-Cerebrovascular modulation in patients with generalized anxiety disorder: an observational study.

    PubMed

    Guo, Zhen-Ni; Feng, Liangshu; Yan, Xiuli; Yang, Le; Huang, Shuo; Xing, Yingqi; Yang, Yi

    2017-07-18

    Generalized anxiety disorder (GAD) has been shown in previous studies to display abnormal cerebral blood flow velocity (CBFV); however, the characteristics of cardio-cerebrovascular modulation are unknown. We aimed to analyze cardio-cerebrovascular modulation using parameters from a supine-to-standing test. There are 2 parts to this study; in Part 1, 125 participants with Hamilton Anxiety scale scores ≥14 were enrolled, and 33 age- and sex-matched medically and psychiatrically healthy volunteers were recruited as control participants. Patients were divided by score into mild, moderate, and severe anxiety groups. The cardio-cerebrovascular modulation using the parameters of dynamic changes of CBFV and heart rate in response to an orthostatic challenge were investigated. In Part 2, we followed up the severe GAD patients for 6 months and repeated the supine-to-standing test, and severe GAD patients were divided into recovery and non-recovery groups. In part 1, the GAD group displayed more marked CBFV and heart rate changes than the healthy group, but there was no difference in the CBFV and heart rate changes from the supine to upright position in mild, moderate, and severe anxiety groups. In part 2, The recovery group demonstrated significant improvement in changes in the CBFV and heart rate values from the supine to the upright position after treatment compared with before treatment. In the non-recovery group, the CBFV and heart rate changes were significantly higher than the healthy group regardless of treatment. Cardio-cerebrovascular modulation is compromised in patients with GAD, however, this impairment can be restored to normal after the disappearance of anxiety.

  9. A clinical study of pattern and factors affecting outcome in Nigerian patients with advanced heart failure.

    PubMed

    Familoni, O B; Olunuga, T O; Olufemi, B W

    2007-01-01

    Advanced heart failure (AHF) accounts for about 25% of all cases of heart failure in Nigeria and is associated with a high mortality rate. To undertake a clinical study of the pattern and outcome of AHF in our hospitalised patients and to determine the parameters associated with mortality and survival in these patients. Eighty-two patients with AHF were studied between January 2003 and December 2005. Baseline blood chemistry and haemodynamics were determined. A congestion score, including orthopnoea, elevated jugular venous pressure, oedema, ascites and loud P2, was derived as well as a low perfusion score. Mortality was computed and risk estimated using the Pearson coefficient and log-ranking test. Cox regression analysis was used to identify the predictors of survival. AHF accounted for 43.6% of all hospitalised heart failure patients, with a total mortality of 67.1%. Hypertension was the commonest cause of AHF. The parameters associated with increased mortality rates included age (r = 0.671; p = 0.02), presence of atrial fibrillation (r = 0.532; p = 0.045) and estimated glomerular filtration rate (r = -0.486, p = 0.04). The majority of patients (54.8%) were in the 'wet and cold' congestion category. The congestion score correlated with mortality. The indices of survival included lower age, lower systolic blood pressure, being literate and lower congestion score. AHF was common in our cohorts of hospitalised heart failure patients and it was associated with a high mortality rate.

  10. Stochastic optimization for the detection of changes in maternal heart rate kinetics during pregnancy

    NASA Astrophysics Data System (ADS)

    Zakynthinaki, M. S.; Barakat, R. O.; Cordente Martínez, C. A.; Sampedro Molinuevo, J.

    2011-03-01

    The stochastic optimization method ALOPEX IV has been successfully applied to the problem of detecting possible changes in the maternal heart rate kinetics during pregnancy. For this reason, maternal heart rate data were recorded before, during and after gestation, during sessions of exercises of constant mild intensity; ALOPEX IV stochastic optimization was used to calculate the parameter values that optimally fit a dynamical systems model to the experimental data. The results not only demonstrate the effectiveness of ALOPEX IV stochastic optimization, but also have important implications in the area of exercise physiology, as they reveal important changes in the maternal cardiovascular dynamics, as a result of pregnancy.

  11. Development of a wearable multi-frequency impedance cardiography device.

    PubMed

    Weyer, Sören; Menden, Tobias; Leicht, Lennart; Leonhardt, Steffen; Wartzek, Tobias

    2015-02-01

    Cardiovascular diseases as well as pulmonary oedema can be early diagnosed using vital signs and thoracic bio-impedance. By recording the electrocardiogram (ECG) and the impedance cardiogram (ICG), vital parameters are captured continuously. The aim of this study is the continuous monitoring of ECG and multi-frequency ICG by a mobile system. A mobile measuring system, based on 'low-power' ECG, ICG and an included radio transmission is described. Due to the high component integration, a board size of only 6.5 cm×5 cm could be realized. The measured data can be transmitted via Bluetooth and visualized on a portable monitor. By using energy-efficient hardware, the system can operate for up to 18 hs with a 3 V battery, continuously sending data via Bluetooth. Longer operating times can be realized by decreased transfer rates. The relative error of the impedance measurement was less than 1%. The ECG and ICG measurements allow an approximate calculation of the heart stroke volume. The ECG and the measured impedance showed a high correlation to commercial devices (r=0.83, p<0.05). In addition to commercial devices, the developed system allows a multi-frequency measurement of the thoracic impedance between 5-150 kHz.

  12. Hemorheology and heart rate variability in patients with diabetes mellitus type 2.

    PubMed

    Velcheva, Irena; Damianov, Petar; Mantarova, Stefka; Antonova, Nadia

    2011-01-01

    Our study aimed to investigate the relationship between hemorheological parameters and heart rate variability (HRV) in patients with diabetes mellitus type 2. Hemorheological variables, including hematocrit (Ht), fibrinogen (Fib), whole blood (WBV) and plasma viscosity (PV) at shear rates of 0.0237 s(-1) to 128.5 s(-1) were examined in 20 patients with diabetes mellitus type 2 and in 10 control subjects. They all underwent non-invasive short-term monitoring of heart rate at rest and after passive head-up tilt. Measurement of the R-R intervals and calculation of the time domain parameters and the power spectral data were performed by our softwear, using fast Fourier transformation. Significant increase of Fib and WBV in the patients in comparison to controls was found within the range of shear rates 0.0237 s(-1) to 128.5 s(-1). In the diabetic patients parallel decrease of the total power (TP), the low frequency spectral power (LF) and of the mean RR and mild increase of the low frequency-high frequency ratio (LF/HF) at rest were established. This tendency was kept after the passive tilt. In patients with diabetes mellitus type 2 the increased blood viscosity was associated with reduced HRV.

  13. Cardiac imaging with multi-sector data acquisition in volumetric CT: variation of effective temporal resolution and its potential clinical consequences

    NASA Astrophysics Data System (ADS)

    Tang, Xiangyang; Hsieh, Jiang; Taha, Basel H.; Vass, Melissa L.; Seamans, John L.; Okerlund, Darin R.

    2009-02-01

    With increasing longitudinal detector dimension available in diagnostic volumetric CT, step-and-shoot scan is becoming popular for cardiac imaging. In comparison to helical scan, step-and-shoot scan decouples patient table movement from cardiac gating/triggering, which facilitates the cardiac imaging via multi-sector data acquisition, as well as the administration of inter-cycle heart beat variation (arrhythmia) and radiation dose efficiency. Ideally, a multi-sector data acquisition can improve temporal resolution at a factor the same as the number of sectors (best scenario). In reality, however, the effective temporal resolution is jointly determined by gantry rotation speed and patient heart beat rate, which may significantly lower than the ideal or no improvement (worst scenario). Hence, it is clinically relevant to investigate the behavior of effective temporal resolution in cardiac imaging with multi-sector data acquisition. In this study, a 5-second cine scan of a porcine heart, which cascades 6 porcine cardiac cycles, is acquired. In addition to theoretical analysis and motion phantom study, the clinical consequences due to the effective temporal resolution variation are evaluated qualitative or quantitatively. By employing a 2-sector image reconstruction strategy, a total of 15 (the permutation of P(6, 2)) cases between the best and worst scenarios are studied, providing informative guidance for the design and optimization of CT cardiac imaging in volumetric CT with multi-sector data acquisition.

  14. Is 50 Hz high enough ECG sampling frequency for accurate HRV analysis?

    PubMed

    Mahdiani, Shadi; Jeyhani, Vala; Peltokangas, Mikko; Vehkaoja, Antti

    2015-01-01

    With the worldwide growth of mobile wireless technologies, healthcare services can be provided at anytime and anywhere. Usage of wearable wireless physiological monitoring system has been extensively increasing during the last decade. These mobile devices can continuously measure e.g. the heart activity and wirelessly transfer the data to the mobile phone of the patient. One of the significant restrictions for these devices is usage of energy, which leads to requiring low sampling rate. This article is presented in order to investigate the lowest adequate sampling frequency of ECG signal, for achieving accurate enough time domain heart rate variability (HRV) parameters. For this purpose the ECG signals originally measured with high 5 kHz sampling rate were down-sampled to simulate the measurement with lower sampling rate. Down-sampling loses information, decreases temporal accuracy, which was then restored by interpolating the signals to their original sampling rates. The HRV parameters obtained from the ECG signals with lower sampling rates were compared. The results represent that even when the sampling rate of ECG signal is equal to 50 Hz, the HRV parameters are almost accurate with a reasonable error.

  15. The treatment with pyridostigmine improves the cardiocirculatory function in rats with chronic heart failure.

    PubMed

    Sabino, João Paulo J; da Silva, Carlos Alberto Aguiar; de Melo, Rubens Fernando; Fazan, Rubens; Salgado, Helio C

    2013-01-01

    Sympathetic hyperactivity and its outcome in heart failure have been thoroughly investigated to determine the focus of pharmacologic approaches targeting the sympathetic nervous system in the treatment of this pathophysiological condition. On the other hand, therapeutic approaches aiming to protect the reduced cardiac parasympathetic function have not received much attention. The present study evaluated rats with chronic heart failure (six to seven weeks after coronary artery ligation) and the effects of an increased parasympathetic function by pyridostigmine (an acetylcholinesterase inhibitor) on the following aspects: arterial pressure (AP), heart rate (HR), baroreceptor and Bezold-Jarisch reflex, pulse interval (PI) and AP variability, cardiac sympathetic and parasympathetic tonus, intrinsic heart rate (i-HR) and cardiac function. Conscious rats with heart failure exhibited no change in HR, Bezold-Jarisch reflex, PI variability and cardiac sympathetic tonus. On the other hand, these animals presented hypotension and reduced baroreflex sensitivity, power in the low frequency (LF) band of the systolic AP spectrum, cardiac parasympathetic tonus and i-HR, while anesthetized rats exhibited reduced cardiac performance. Pyridostigmine prevented the attenuation of all the parameters examined, except basal AP and cardiac performance. In conclusion, the blockade of acetylcholinesterase with pyridostigmine was revealed to be an important pharmacological approach, which could be used to increase parasympathetic function and to improve a number of cardiocirculatory parameters in rats with heart failure. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Stability, Consistency and Performance of Distribution Entropy in Analysing Short Length Heart Rate Variability (HRV) Signal

    PubMed Central

    Karmakar, Chandan; Udhayakumar, Radhagayathri K.; Li, Peng; Venkatesh, Svetha; Palaniswami, Marimuthu

    2017-01-01

    Distribution entropy (DistEn) is a recently developed measure of complexity that is used to analyse heart rate variability (HRV) data. Its calculation requires two input parameters—the embedding dimension m, and the number of bins M which replaces the tolerance parameter r that is used by the existing approximation entropy (ApEn) and sample entropy (SampEn) measures. The performance of DistEn can also be affected by the data length N. In our previous studies, we have analyzed stability and performance of DistEn with respect to one parameter (m or M) or combination of two parameters (N and M). However, impact of varying all the three input parameters on DistEn is not yet studied. Since DistEn is predominantly aimed at analysing short length heart rate variability (HRV) signal, it is important to comprehensively study the stability, consistency and performance of the measure using multiple case studies. In this study, we examined the impact of changing input parameters on DistEn for synthetic and physiological signals. We also compared the variations of DistEn and performance in distinguishing physiological (Elderly from Young) and pathological (Healthy from Arrhythmia) conditions with ApEn and SampEn. The results showed that DistEn values are minimally affected by the variations of input parameters compared to ApEn and SampEn. DistEn also showed the most consistent and the best performance in differentiating physiological and pathological conditions with various of input parameters among reported complexity measures. In conclusion, DistEn is found to be the best measure for analysing short length HRV time series. PMID:28979215

  17. Association between resting heart rate, metabolic syndrome and cardiorespiratory fitness in Korean male adults.

    PubMed

    Kang, Seol-Jung; Ha, Gi-Chul; Ko, Kwang-Jun

    2017-06-01

    The present study aimed to investigate the association between metabolic syndrome and cardiorespiratory fitness according to resting heart rate of Korean male adults. A total of 11,876 male adults aged 20-65 years who underwent health examinations from 2010 to 2015 at a National Fitness Centre in South Korea were included. Subjects' resting heart rate, cardiorespiratory fitness (VO 2 max), and metabolic syndrome parameters were collected. The subjects were divided into 5 categories (<60 bpm, 60-69 bpm, 70-79 bpm, 80-89 bpm, and ≥90 bpm) of resting heart rate for further analysis. We found that elevated resting heart rate was positively associated with body mass index, systolic blood pressure, diastolic blood pressure, triglycerides, and fasting blood glucose levels ( p  < 0.001, respectively); in contrast, elevated resting heart rate was inversely associated with VO 2 max ( p  < 0.001). When resting heart rate of subjects was categorized into quintiles and analysed, the results showed that the relative risk of metabolic syndrome was 1.53-fold higher (95% CI, 1.34 to 1.82) in the range of 60-69 beats per minute (bpm), 2.08-fold higher (95% CI, 1.77 to 2.45) in the range of 70-79 bpm, 2.28-fold higher (95% CI, 1.73 to 3.00) in the range of 80-89 bpm, and 2.61-fold higher (95% CI, 1.62 to 4.20) in the range of ≥90 bpm, compared to those <60 bpm; this indicated that as resting heart rate increased, the relative risk of metabolic syndrome also increased. Resting heart rate of male adults was found to be associated with cardiorespiratory fitness; the risk factors for metabolic syndrome and relative risk of metabolic syndrome increased as resting heart rate increased.

  18. Heart Dose Is an Independent Dosimetric Predictor of Overall Survival in Locally Advanced Non-Small Cell Lung Cancer.

    PubMed

    Speirs, Christina K; DeWees, Todd A; Rehman, Sana; Molotievschi, Alerson; Velez, Maria A; Mullen, Daniel; Fergus, Sandra; Trovo, Marco; Bradley, Jeffrey D; Robinson, Cliff G

    2017-02-01

    In the randomized trial of standard- versus high-dose chemoradiotherapy for locally advanced (LA) NSCLC (Radiation Therapy Oncology Group 0617), overall survival (OS) was worse in the high-dose arm. Although heart dose was suggested as a contributing factor, actionable parameters have not been established. We present an analysis of clinical and dosimetric parameters affecting OS in this patient population, focusing on heart dose. Clinical data were collected on 416 patients with LA NSCLC treated at a single institution, with a subset of 333 available treatment plans recontoured using Radiation Therapy Oncology Group 0617 normal tissue guidelines. Toxicity and dosimetry data were analyzed for 322 patients; multivariate analysis was performed on 251 patients. Dosimetric parameters of radiation to tumor and organs at risk were analyzed with clinical data pertaining to OS, disease-free survival, and toxicity. Patients were treated with radiation therapy to prescribed doses of 50.0 to 84.9 Gy (median 66.0 Gy). Median follow-up was 14.5 months. Median OS was 16.8 months. The 1- and 2-year OS rates were 61.4% and 38.8%, respectively. On multivariate analysis, factors independently associated with worse OS were increasing heart V 50 (volume receiving ≥50 Gy), heart volume, lung V 5 (proportion of the lung structure [excluding the target volume]) receiving at least 5 Gy), bilateral mediastinal lymph node involvement, and lack of concurrent chemotherapy. When stratified by heart V 50 less than 25% versus 25% or greater, the 1-year OS rates were 70.2% versus 46.8% and the 2-year OS rates were 45.9% versus 26.7% (p < 0.0001). Median heart V 50 was significantly higher (20.8% versus 13.9%, p < 0.0001) for patients with cardiac toxicity with a Common Terminology Criteria for Adverse Events grade of 1 or higher. Heart dose is associated with OS and cardiac toxicity for patients with LA NSCLC treated with chemoradiotherapy. Copyright © 2016 International Association for the Study of Lung Cancer. Published by Elsevier Inc. All rights reserved.

  19. Cloud storage based mobile assessment facility for patients with post-traumatic stress disorder using integrated signal processing algorithm

    NASA Astrophysics Data System (ADS)

    Balbin, Jessie R.; Pinugu, Jasmine Nadja J.; Basco, Abigail Joy S.; Cabanada, Myla B.; Gonzales, Patrisha Melrose V.; Marasigan, Juan Carlos C.

    2017-06-01

    The research aims to build a tool in assessing patients for post-traumatic stress disorder or PTSD. The parameters used are heart rate, skin conductivity, and facial gestures. Facial gestures are recorded using OpenFace, an open-source face recognition program that uses facial action units in to track facial movements. Heart rate and skin conductivity is measured through sensors operated using Raspberry Pi. Results are stored in a database for easy and quick access. Databases to be used are uploaded to a cloud platform so that doctors have direct access to the data. This research aims to analyze these parameters and give accurate assessment of the patient.

  20. Changes in heart rate variability during TOVA testing in patients with major depressive disorder.

    PubMed

    Shen, Tsu-Wang; Liu, Fang-Chih; Chen, Shaw-Ji; Chen, Shao-Tsu

    2013-01-01

    The aim of this study was to identify major depressive disorder (MDD) based on heart rate variability (HRV) during tests of variables of attention (TOVA). Forty-five MDD patients without cardiovascular disease and 45 controls matched by age and gender participated in this study. Compared to the controls, the MDD group had lower resting HRV parameters, more omissions and variability and longer response times on TOVA, and failure of attention employment to decrease HRV. The resting HRV parameters may provide easily measured, clinically useful ways to identify patients with MDD and to monitor their progress in treatment. © 2013 The Authors. Psychiatry and Clinical Neurosciences © 2013 Japanese Society of Psychiatry and Neurology.

  1. Integrating multi-scale data to create a virtual physiological mouse heart.

    PubMed

    Land, Sander; Niederer, Steven A; Louch, William E; Sejersted, Ole M; Smith, Nicolas P

    2013-04-06

    While the virtual physiological human (VPH) project has made great advances in human modelling, many of the tools and insights developed as part of this initiative are also applicable for facilitating mechanistic understanding of the physiology of a range of other species. This process, in turn, has the potential to provide human relevant insights via a different scientific path. Specifically, the increasing use of mice in experimental research, not yet fully complemented by a similar increase in computational modelling, is currently missing an important opportunity for using and interpreting this growing body of experimental data to improve our understanding of cardiac function. This overview describes our work to address this issue by creating a virtual physiological mouse model of the heart. We describe the similarities between human- and mouse-focused modelling, including the reuse of VPH tools, and the development of methods for investigating parameter sensitivity that are applicable across species. We show how previous results using this approach have already provided important biological insights, and how these can also be used to advance VPH heart models. Finally, we show an example application of this approach to test competing multi-scale hypotheses by investigating variations in length-dependent properties of cardiac muscle.

  2. Integrating multi-scale data to create a virtual physiological mouse heart

    PubMed Central

    Land, Sander; Niederer, Steven A.; Louch, William E.; Sejersted, Ole M.; Smith, Nicolas P.

    2013-01-01

    While the virtual physiological human (VPH) project has made great advances in human modelling, many of the tools and insights developed as part of this initiative are also applicable for facilitating mechanistic understanding of the physiology of a range of other species. This process, in turn, has the potential to provide human relevant insights via a different scientific path. Specifically, the increasing use of mice in experimental research, not yet fully complemented by a similar increase in computational modelling, is currently missing an important opportunity for using and interpreting this growing body of experimental data to improve our understanding of cardiac function. This overview describes our work to address this issue by creating a virtual physiological mouse model of the heart. We describe the similarities between human- and mouse-focused modelling, including the reuse of VPH tools, and the development of methods for investigating parameter sensitivity that are applicable across species. We show how previous results using this approach have already provided important biological insights, and how these can also be used to advance VPH heart models. Finally, we show an example application of this approach to test competing multi-scale hypotheses by investigating variations in length-dependent properties of cardiac muscle. PMID:24427525

  3. Prognostic value of heart rate variability footprint and standard deviation of average 5-minute intrinsic R-R intervals for mortality in cardiac resynchronization therapy patients.

    PubMed

    Gilliam, F Roosevelt; Singh, Jagmeet P; Mullin, Christopher M; McGuire, Maureen; Chase, Kellie J

    2007-10-01

    Cardiac resynchronization therapy devices provide effective therapy for heart failure. Heart rate variability (HRV) parameters in the device such as HRV footprint and SD of average 5-minute intrinsic R-R intervals (SDANN) are related to autonomic function and may be used to identify patients with a higher risk of mortality. We examined the relationship between HRV and mortality in a prospective cohort study. The 842 patients (mean age, 67.7 +/- 11.2; 23.5 % female; New York Heart Association class III, 88.6%; class IV, 11.4%) included in the analysis were implanted with a cardiac resynchronization therapy with defibrillation device and had baseline HRV measurements available. During a median of 11.6 months of follow-up, 7.8% (66/842) of patients died. Heart rate variability footprint and SDANN were significant predictors of mortality (all P < .05); patients with lower HRV values were at greater risk for death, compared with patients with higher HRV values. Heart rate variability changes over time tended to predict the risk of mortality in follow-up (P = nonsignificant); patients with low baseline HRV and small changes in HRV during the follow-up period were at the highest risk for death (7% mortality for SDANN and 8.9% for HRV footprint), and patients with high baseline HRV and large changes in HRV were at the lowest risk (1.5% mortality for SDANN and 2.4% for HRV footprint). Results were consistent when adjusted for age, sex, body mass index, and diastolic blood pressure. Continuously measured device HRV parameters provide prognostic information about patient mortality that may be helpful for risk stratification.

  4. HRV Analysis to Identify Stages of Home-based Telerehabilitation Exercise.

    PubMed

    Jeong, In Cheol; Finkelstein, Joseph

    2014-01-01

    Spectral analysis of heart rate variability (HRV) has been widely used to investigate activity of autonomous nervous system. Previous studies demonstrated potential of analysis of short-term sequences of heart rate data in a time domain for continuous monitoring of levels of physiological stress however the value of HRV parameters in frequency domain for monitoring cycling exercise has not been established. The goal of this study was to assess whether HRV parameters in frequency domain differ depending on a stage of cycling exercise. We compared major HRV parameters in high, low and very low frequency ranges during rest, height of exercise, and recovery during cycling exercise. Our results indicated responsiveness of frequency-domain indices to different phases of cycling exercise program and their potential in monitoring autonomic balance and stress levels as a part of a tailored home-based telerehabilitation program.

  5. Predictors of incident heart failure in patients after an acute coronary syndrome: The LIPID heart failure risk-prediction model.

    PubMed

    Driscoll, Andrea; Barnes, Elizabeth H; Blankenberg, Stefan; Colquhoun, David M; Hunt, David; Nestel, Paul J; Stewart, Ralph A; West, Malcolm J; White, Harvey D; Simes, John; Tonkin, Andrew

    2017-12-01

    Coronary heart disease is a major cause of heart failure. Availability of risk-prediction models that include both clinical parameters and biomarkers is limited. We aimed to develop such a model for prediction of incident heart failure. A multivariable risk-factor model was developed for prediction of first occurrence of heart failure death or hospitalization. A simplified risk score was derived that enabled subjects to be grouped into categories of 5-year risk varying from <5% to >20%. Among 7101 patients from the LIPID study (84% male), with median age 61years (interquartile range 55-67years), 558 (8%) died or were hospitalized because of heart failure. Older age, history of claudication or diabetes mellitus, body mass index>30kg/m 2 , LDL-cholesterol >2.5mmol/L, heart rate>70 beats/min, white blood cell count, and the nature of the qualifying acute coronary syndrome (myocardial infarction or unstable angina) were associated with an increase in heart failure events. Coronary revascularization was associated with a lower event rate. Incident heart failure increased with higher concentrations of B-type natriuretic peptide >50ng/L, cystatin C>0.93nmol/L, D-dimer >273nmol/L, high-sensitivity C-reactive protein >4.8nmol/L, and sensitive troponin I>0.018μg/L. Addition of biomarkers to the clinical risk model improved the model's C statistic from 0.73 to 0.77. The net reclassification improvement incorporating biomarkers into the clinical model using categories of 5-year risk was 23%. Adding a multibiomarker panel to conventional parameters markedly improved discrimination and risk classification for future heart failure events. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  6. Spot measurement of heart rate based on morphology of PhotoPlethysmoGraphic (PPG) signals.

    PubMed

    Madhan Mohan, P; Nagarajan, V; Vignesh, J C

    2017-02-01

    Due to increasing health consciousness among people, it is imperative to have low-cost health care devices to measure the vital parameters like heart rate and arterial oxygen saturation (SpO 2 ). In this paper, an efficient heart rate monitoring algorithm based on the morphology of photoplethysmography (PPG) signals to measure the spot heart rate (HR) and its real-time implementation is proposed. The algorithm does pre-processing and detects the onsets and systolic peaks of the PPG signal to estimate the heart rate of the subject. Since the algorithm is based on the morphology of the signal, it works well when the subject is not moving, which is a typical test case. So, this algorithm is developed mainly to measure the heart rate at on-demand applications. Real-time experimental results indicate the heart rate accuracy of 99.5%, mean absolute percentage error (MAPE) of 1.65%, mean absolute error (MAE) of 1.18 BPM and reference closeness factor (RCF) of 0.988. The results further show that the average response time of the algorithm to give the spot HR is 6.85 s, so that the users need not wait longer to see their HR. The hardware implementation results show that the algorithm only requires 18 KBytes of total memory and runs at high speed with 0.85 MIPS. So, this algorithm can be targeted to low-cost embedded platforms.

  7. OLAM: A wearable, non-contact sensor for continuous heart-rate and activity monitoring.

    PubMed

    Albright, Ryan K; Goska, Benjamin J; Hagen, Tory M; Chi, Mike Y; Cauwenberghs, G; Chiang, Patrick Y

    2011-01-01

    A wearable, multi-modal sensor is presented that can non-invasively monitor a patient's activity level and heart function concurrently for more than a week. The 4 in(2) sensor incorporates both a non-contact heartrate sensor and a 5-axis inertial measurement unit (IMU), allowing simultaneous heart, respiration, and movement monitoring without requiring physical contact with the skin [1]. Hence, this Oregon State University Life and Activity Monitor (OLAM) provides the unique opportunity to combine motion data with heart-rate information, enabling assessment of actual physical activity beyond conventional movement sensors. OLAM also provides a unique platform for non-contact sensing, enabling the filtering of movement artifacts generated by the non-contact capacitive interface, using the IMU data as a movement noise channel. Intended to be used in clinical trials for weeks at a time with no physician intervention, the OLAM allows continuous non-invasive monitoring of patients, providing the opportunity for long-term observation into a patient's physical activity and subtle longitudinal changes.

  8. Development of an Ex Vivo, Beating Heart Model for CT Myocardial Perfusion

    PubMed Central

    Das, Marco; Haberland, Ulrike; Slump, Cees; Handayani, Astri; van Tuijl, Sjoerd; Stijnen, Marco; Oudkerk, Matthijs; Wildberger, Joachim E.; Vliegenthart, Rozemarijn

    2015-01-01

    Objective. To test the feasibility of a CT-compatible, ex vivo, perfused porcine heart model for myocardial perfusion CT imaging. Methods. One porcine heart was perfused according to Langendorff. Dynamic perfusion scanning was performed with a second-generation dual source CT scanner. Circulatory parameters like blood flow, aortic pressure, and heart rate were monitored throughout the experiment. Stenosis was induced in the circumflex artery, controlled by a fractional flow reserve (FFR) pressure wire. CT-derived myocardial perfusion parameters were analysed at FFR of 1 to 0.10/0.0. Results. CT images did not show major artefacts due to interference of the model setup. The pacemaker-induced heart rhythm was generally stable at 70 beats per minute. During most of the experiment, blood flow was 0.9–1.0 L/min, and arterial pressure varied between 80 and 95 mm/Hg. Blood flow decreased and arterial pressure increased by approximately 10% after inducing a stenosis with FFR ≤ 0.50. Dynamic perfusion scanning was possible across the range of stenosis grades. Perfusion parameters of circumflex-perfused myocardial segments were affected at increasing stenosis grades. Conclusion. An adapted Langendorff porcine heart model is feasible in a CT environment. This model provides control over physiological parameters and may allow in-depth validation of quantitative CT perfusion techniques. PMID:26185756

  9. Use of Heart Rate Variability and Photoplethysmograph-Derived Parameters as Assessment Signals of Radiofrequency Therapy Efficacy for Chronic Pain.

    PubMed

    Ye, Jing-Jhao; Chuang, Chiung-Cheng; Tai, Yu-Ting; Lee, Kuan-Ting; Hung, Kuo-Sheng

    2017-09-01

    Radiofrequency therapy (RFT) generates molecular motion and produces heat and electromagnetic effects on tissues, which attenuate pain sensation and thereby relieve pain. This study was to observe the altering trend of physiological parameters after RFT for chronic cervical or lumbar pain. This study recruited 66 patients with chronic cervical or lumbar pain and recorded their physiological parameters before and after RFT using heart rate variability (HRV) and photoplethysmography (PPG) to explore the feasibility of RFT efficacy assessment. The patients' visual analog scale scores significantly decreased after RFT and the HRV parameters that represented parasympathetic activity significantly changed (HR decreased, and R-R interval and low- and high-frequency power increased significantly). Meanwhile, the PPG parameters that represented sympathetic activity also increased (PPG amplitude and autonomic nervous system state significantly decreased). This study showed significant efficacy of RFT in patients with chronic cervical or lumbar pain. The changes of HRV and PPG parameters may explain part of the mechanisms of RFT. © 2016 World Institute of Pain.

  10. Multiscale power analysis for heart rate variability

    NASA Astrophysics Data System (ADS)

    Zeng, Peng; Liu, Hongxing; Ni, Huangjing; Zhou, Jing; Xia, Lan; Ning, Xinbao

    2015-06-01

    We first introduce multiscale power (MSP) method to assess the power distribution of physiological signals on multiple time scales. Simulation on synthetic data and experiments on heart rate variability (HRV) are tested to support the approach. Results show that both physical and psychological changes influence power distribution significantly. A quantitative parameter, termed power difference (PD), is introduced to evaluate the degree of power distribution alteration. We find that dynamical correlation of HRV will be destroyed completely when PD>0.7.

  11. Orthostatic Hypotension and Elevated Resting Heart Rate Predict Low-Energy Fractures in the Population: The Malmö Preventive Project.

    PubMed

    Hamrefors, Viktor; Härstedt, Maria; Holmberg, Anna; Rogmark, Cecilia; Sutton, Richard; Melander, Olle; Fedorowski, Artur

    2016-01-01

    Autonomic disorders of the cardiovascular system, such as orthostatic hypotension and elevated resting heart rate, predict mortality and cardiovascular events in the population. Low-energy-fractures constitute a substantial clinical problem that may represent an additional risk related to such autonomic dysfunction. To test the association between orthostatic hypotension, resting heart rate and incidence of low-energy-fractures in the general population. Using multivariable-adjusted Cox regression models we investigated the association between orthostatic blood pressure response, resting heart rate and first incident low-energy-fracture in a population-based, middle-aged cohort of 33 000 individuals over 25 years follow-up. The median follow-up time from baseline to first incident fracture among the subjects that experienced a low energy fracture was 15.0 years. A 10 mmHg orthostatic decrease in systolic blood pressure at baseline was associated with 5% increased risk of low-energy-fractures (95% confidence interval 1.01-1.10) during follow-up, whereas the resting heart rate predicted low-energy-fractures with an effect size of 8% increased risk per 10 beats-per-minute (1.05-1.12), independently of the orthostatic response. Subjects with a resting heart rate exceeding 68 beats-per-minute had 18% (1.10-1.26) increased risk of low-energy-fractures during follow-up compared with subjects with a resting heart rate below 68 beats-per-minute. When combining the orthostatic response and resting heart rate, there was a 30% risk increase (1.08-1.57) of low-energy-fractures between the extremes, i.e. between subjects in the fourth compared with the first quartiles of both resting heart rate and systolic blood pressure-decrease. Orthostatic blood pressure decline and elevated resting heart rate independently predict low-energy fractures in a middle-aged population. These two measures of subclinical cardiovascular dysautonomia may herald increased risks many years in advance, even if symptoms may not be detectable. Although the effect sizes are moderate, the easily accessible clinical parameters of orthostatic blood pressure response and resting heart rate deserve consideration as new risk predictors to yield more accurate decisions on primary prevention of low-energy fractures.

  12. Office and 24-hour heart rate and target organ damage in hypertensive patients

    PubMed Central

    2012-01-01

    Background We investigated the association between heart rate and its variability with the parameters that assess vascular, renal and cardiac target organ damage. Methods A cross-sectional study was performed including a consecutive sample of 360 hypertensive patients without heart rate lowering drugs (aged 56 ± 11 years, 64.2% male). Heart rate (HR) and its standard deviation (HRV) in clinical and 24-hour ambulatory monitoring were evaluated. Renal damage was assessed by glomerular filtration rate and albumin/creatinine ratio; vascular damage by carotid intima-media thickness and ankle/brachial index; and cardiac damage by the Cornell voltage-duration product and left ventricular mass index. Results There was a positive correlation between ambulatory, but not clinical, heart rate and its standard deviation with glomerular filtration rate, and a negative correlation with carotid intima-media thickness, and night/day ratio of systolic and diastolic blood pressure. There was no correlation with albumin/creatinine ratio, ankle/brachial index, Cornell voltage-duration product or left ventricular mass index. In the multiple linear regression analysis, after adjusting for age, the association of glomerular filtration rate and intima-media thickness with ambulatory heart rate and its standard deviation was lost. According to the logistic regression analysis, the predictors of any target organ damage were age (OR = 1.034 and 1.033) and night/day systolic blood pressure ratio (OR = 1.425 and 1.512). Neither 24 HR nor 24 HRV reached statistical significance. Conclusions High ambulatory heart rate and its variability, but not clinical HR, are associated with decreased carotid intima-media thickness and a higher glomerular filtration rate, although this is lost after adjusting for age. Trial Registration ClinicalTrials.gov: NCT01325064 PMID:22439900

  13. Frailty Assessment in Heart Failure: an Overview of the Multi-domain Approach.

    PubMed

    McDonagh, Julee; Ferguson, Caleb; Newton, Phillip J

    2018-02-01

    The study aims (1) to provide a contemporary description of frailty assessment in heart failure and (2) to provide an overview of multi-domain frailty assessment in heart failure. Frailty assessment is an important predictive measure for mortality and hospitalisation in individuals with heart failure. To date, there are no frailty assessment instruments validated for use in heart failure. This has resulted in significant heterogeneity between studies regarding the assessment of frailty. The most common frailty assessment instrument used in heart failure is the Frailty Phenotype which focuses on five physical domains of frailty; the appropriateness a purely physical measure of frailty in individuals with heart failure who frequently experience decreased exercise tolerance and shortness of breath is yet to be determined. A limited number of studies have approached frailty assessment using a multi-domain view which may be more clinically relevant in heart failure. There remains a lack of consensus regarding frailty assessment and an absence of a validated instrument in heart failure. Despite this, frailty continues to be assessed frequently, primarily for research purposes, using predominantly physical frailty measures. A more multidimensional view of frailty assessment using a multi-domain approach will likely be more sensitive to identifying at risk patients.

  14. Clinical safety of 3-T brain magnetic resonance imaging in newborns.

    PubMed

    Fumagalli, Monica; Cinnante, Claudia Maria; Calloni, Sonia Francesca; Sorrentino, Gabriele; Gorla, Ilaria; Plevani, Laura; Pesenti, Nicola; Sirgiovanni, Ida; Mosca, Fabio; Triulzi, Fabio

    2018-03-29

    The effects and potential hazards of brain magnetic resonance imaging (MRI) at 3 T in newborns are debated. Assess the impact of 3-T MRI in newborns on body temperature and physiological parameters. Forty-nine newborns, born preterm and at term, underwent 3-T brain MRI at term-corrected age. Rectal and skin temperature, oxygen saturation and heart rate were recorded before, during and after the scan. A statistically significant increase in skin temperature of 0.6 °C was observed at the end of the MRI scan (P<0.01). There was no significant changes in rectal temperature, heart rate or oxygen saturation. Core temperature, heart rate and oxygen saturation in newborns were not affected by 3-T brain MR scanning.

  15. Prenatal Antecedents of Newborn Neurological Maturation

    PubMed Central

    DiPietro, Janet A.; Kivlighan, Katie T.; Costigan, Kathleen A.; Rubin, Suzanne E.; Shiffler, Dorothy E.; Henderson, Janice L.; Pillion, Joseph P.

    2009-01-01

    Fetal neurobehavioral development was modeled longitudinally using data collected at weekly intervals from 24- to -38 weeks gestation in a sample of 112 healthy pregnancies. Predictive associations between 3 measures of fetal neurobehavioral functioning and their developmental trajectories to neurological maturation in the 1st weeks after birth were examined. Prenatal measures included fetal heart rate variability, fetal movement, and coupling between fetal motor activity and heart rate patterning; neonatal outcomes include a standard neurologic examination (n = 97) and brainstem auditory evoked potential (BAEP; n = 47). Optimality in newborn motor activity and reflexes was predicted by fetal motor activity; fetal heart rate variability and somatic-cardiac coupling predicted BAEP parameters. Maternal pregnancy-specific psychological stress was associated with accelerated neurologic maturation. PMID:20331657

  16. A remote monitoring and telephone nurse coaching intervention to reduce readmissions among patients with heart failure: study protocol for the Better Effectiveness After Transition - Heart Failure (BEAT-HF) randomized controlled trial.

    PubMed

    Black, Jeanne T; Romano, Patrick S; Sadeghi, Banafsheh; Auerbach, Andrew D; Ganiats, Theodore G; Greenfield, Sheldon; Kaplan, Sherrie H; Ong, Michael K

    2014-04-13

    Heart failure is a prevalent health problem associated with costly hospital readmissions. Transitional care programs have been shown to reduce readmissions but are costly to implement. Evidence regarding the effectiveness of telemonitoring in managing the care of this chronic condition is mixed. The objective of this randomized controlled comparative effectiveness study is to evaluate the effectiveness of a care transition intervention that includes pre-discharge education about heart failure and post-discharge telephone nurse coaching combined with home telemonitoring of weight, blood pressure, heart rate, and symptoms in reducing all-cause 180-day hospital readmissions for older adults hospitalized with heart failure. A multi-center, randomized controlled trial is being conducted at six academic health systems in California. A total of 1,500 patients aged 50 years and older will be enrolled during a hospitalization for treatment of heart failure. Patients in the intervention group will receive intensive patient education using the 'teach-back' method and receive instruction in using the telemonitoring equipment. Following hospital discharge, they will receive a series of nine scheduled health coaching telephone calls over 6 months from nurses located in a centralized call center. The nurses also will call patients and patients' physicians in response to alerts generated by the telemonitoring system, based on predetermined parameters. The primary outcome is readmission for any cause within 180 days. Secondary outcomes include 30-day readmission, mortality, hospital days, emergency department (ED) visits, hospital cost, and health-related quality of life. BEAT-HF is one of the largest randomized controlled trials of telemonitoring in patients with heart failure, and the first explicitly to adapt the care transition approach and combine it with remote telemonitoring. The study population also includes patients with a wide range of demographic and socioeconomic characteristics. Once completed, the study will be a rich resource of information on how best to use remote technology in the care management of patients with chronic heart failure. ClinicalTrials.gov # NCT01360203.

  17. QRS peak detection for heart rate monitoring on Android smartphone

    NASA Astrophysics Data System (ADS)

    Pambudi Utomo, Trio; Nuryani, Nuryani; Darmanto

    2017-11-01

    In this study, Android smartphone is used for heart rate monitoring and displaying electrocardiogram (ECG) graph. Heart rate determination is based on QRS peak detection. Two methods are studied to detect the QRS complex peak; they are Peak Threshold and Peak Filter. The acquisition of ECG data is utilized by AD8232 module from Analog Devices, three electrodes, and Microcontroller Arduino UNO R3. To record the ECG data from a patient, three electrodes are attached to particular body’s surface of a patient. Patient’s heart activity which is recorded by AD8232 module is decoded by Arduino UNO R3 into analog data. Then, the analog data is converted into a voltage value (mV) and is processed to get the QRS complex peak. Heart rate value is calculated by Microcontroller Arduino UNO R3 uses the QRS complex peak. Voltage, heart rate, and the QRS complex peak are sent to Android smartphone by Bluetooth HC-05. ECG data is displayed as the graph by Android smartphone. To evaluate the performance of QRS complex peak detection method, three parameters are used; they are positive predictive, accuracy and sensitivity. Positive predictive, accuracy, and sensitivity of Peak Threshold method is 92.39%, 70.30%, 74.62% and for Peak Filter method are 98.38%, 82.47%, 83.61%, respectively.

  18. Inhalation of ultrafine carbon particles alters heart rate and heart rate variability in people with type 2 diabetes.

    PubMed

    Vora, Rathin; Zareba, Wojciech; Utell, Mark J; Pietropaoli, Anthony P; Chalupa, David; Little, Erika L; Oakes, David; Bausch, Jan; Wiltshire, Jelani; Frampton, Mark W

    2014-07-16

    Diabetes may confer an increased risk for the cardiovascular health effects of particulate air pollution, but few human clinical studies of air pollution have included people with diabetes. Ultrafine particles (UFP, ≤100 nm in diameter) have been hypothesized to be an important component of particulate air pollution with regard to cardiovascular health effects. 17 never-smoker subjects 30-60 years of age, with stable type 2 diabetes but otherwise healthy, inhaled either filtered air (0-10 particles/cm3) or elemental carbon UFP (~107 particles/cm3, ~50 ug/m3, count median diameter 32 nm) by mouthpiece, for 2 hours at rest, in a double-blind, randomized, crossover study design. A digital 12-lead electrocardiogram (ECG) was recorded continuously for 48 hours, beginning 1 hour prior to exposure. Analysis of 5-minute segments of the ECG during quiet rest showed reduced high-frequency heart rate variability with UFP relative to air exposure (p = 0.014), paralleled by non-significant reductions in time-domain heart rate variability parameters. In the analysis of longer durations of the ECG, we found that UFP exposure increased the heart rate relative to air exposure. During the 21- to 45-hour interval after exposure, the average heart rate increased approximately 8 beats per minute with UFP, compared to 5 beats per minute with air (p = 0.045). There were no UFP effects on cardiac rhythm or repolarization. Inhalation of elemental carbon ultrafine particles alters heart rate and heart rate variability in people with type 2 diabetes. Our findings suggest that effects may occur and persist hours after a single 2-hour exposure.

  19. Studies in Fetal Behavior: Revisited, Renewed, and Reimagined

    PubMed Central

    DiPietro, Janet A.; Costigan, Kathleen A.; Voegtline, Kristin M.

    2016-01-01

    Among the earliest volumes of this Monograph series was a report by Lester Sontag and colleagues, of the esteemed Fels Institute, on the heart rate of the human fetus as an expression of the developing nervous system. Here, some 75 years later, we commemorate this work and provide historical and contemporary context on knowledge regarding fetal development, as well as results from our own research. These are based on synchronized monitoring of maternal and fetal parameters assessed between 24 and 36 weeks gestation on 740 maternal-fetal pairs compiled from eight separate longitudinal studies, which commenced in the early 1990s. Data include maternal heart rate, respiratory sinus arrhythmia, and electrodermal activity and fetal heart rate, motor activity, and their integration. Hierarchical linear modeling of developmental trajectories reveals that the fetus develops in predictable ways consistent with advancing parasympathetic regulation. Findings also include: within-fetus stability (i.e., preservation of rank ordering over time) for heart rate, motor, and coupling measures; a transitional period of decelerating development near 30 weeks gestation; sex differences in fetal heart rate measures but not in most fetal motor activity measures; modest correspondence in fetal neurodevelopment among siblings as compared to unrelated fetuses; and deviations from normative fetal development in fetuses affected by intrauterine growth restriction and other conditions. Maternal parameters also change during this period of gestation and there is evidence that fetal sex and individual variation in fetal neurobehavior influence maternal physiological processes and the local intrauterine context. Results are discussed within the framework of neuromaturation, the emergence of individual differences, and the bidirectional nature of the maternal-fetal relationship. We pose a number of open questions for future research. Although the human fetus remains just out of reach, new technologies portend an era of accelerated discovery of the earliest period of development. PMID:26303396

  20. Stochastic optimization for modeling physiological time series: application to the heart rate response to exercise

    NASA Astrophysics Data System (ADS)

    Zakynthinaki, M. S.; Stirling, J. R.

    2007-01-01

    Stochastic optimization is applied to the problem of optimizing the fit of a model to the time series of raw physiological (heart rate) data. The physiological response to exercise has been recently modeled as a dynamical system. Fitting the model to a set of raw physiological time series data is, however, not a trivial task. For this reason and in order to calculate the optimal values of the parameters of the model, the present study implements the powerful stochastic optimization method ALOPEX IV, an algorithm that has been proven to be fast, effective and easy to implement. The optimal parameters of the model, calculated by the optimization method for the particular athlete, are very important as they characterize the athlete's current condition. The present study applies the ALOPEX IV stochastic optimization to the modeling of a set of heart rate time series data corresponding to different exercises of constant intensity. An analysis of the optimization algorithm, together with an analytic proof of its convergence (in the absence of noise), is also presented.

  1. Short-term water-based aerobic training promotes improvements in aerobic conditioning parameters of mature women.

    PubMed

    Costa, Rochelle Rocha; Reichert, Thais; Coconcelli, Leandro; Simmer, Nicole Monticelli; Bagatini, Natália Carvalho; Buttelli, Adriana Cristine Koch; Bracht, Cláudia Gomes; Stein, Ricardo; Kruel, Luiz Fernando Martins

    2017-08-01

    Aging is accompanied by a decrease in aerobic capacity. Therefore, physical training has been recommended to soften the effects of advancement age. The aim of this study was to assess the effects of a short-term water-based aerobic training on resting heart rate (HR rest ), heart rate corresponding to anaerobic threshold (HR AT ), peak heart rate (HR peak ), percentage value of HR AT in relation to HR peak and test duration (TD) of mature women. Twenty-two women (65.91 ± 4.83 years) were submitted to a five-week water-based interval aerobic training. Aerobic capacity parameters were evaluated through an aquatic incremental test. After training, there was an increase in TD (16%) and HR AT percentage in relation to HR peak (4.68%), and a reduction of HR rest (9%). It is concluded that a water-based aerobic interval training prescribed through HR AT of only five weeks is able to promote improvements in aerobic capacity of mature women. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. The effect of live classical piano music on the vital signs of patients undergoing ophthalmic surgery.

    PubMed

    Camara, Jorge G; Ruszkowski, Joseph M; Worak, Sandra R

    2008-06-25

    Music and surgery. To determine the effect of live classical piano music on vital signs of patients undergoing ophthalmic surgery. Retrospective case series. 203 patients who underwent various ophthalmologic procedures in a period during which a piano was present in the operating room of St. Francis Medical Center. [Note: St. Francis Medical Center has recently been renamed Hawaii Medical Center East.] Demographic data, surgical procedures, and the vital signs of 203 patients who underwent ophthalmic procedures were obtained from patient records. Blood pressure, heart rate, and respiratory rate measured in the preoperative holding area were compared with the same parameters taken in the operating room, with and without exposure to live piano music. A paired t-test was used for statistical analysis. Mean arterial pressure, heart rate, and respiratory rate. 115 patients who were exposed to live piano music showed a statistically significant decrease in mean arterial blood pressure, heart rate, and respiratory rate in the operating room compared with their vital signs measured in the preoperative holding area (P < .0001). The control group of 88 patients not exposed to live piano music showed a statistically significant increase in mean arterial blood pressure (P < .0002) and heart rate and respiratory rate (P < .0001). Live classical piano music lowered the blood pressure, heart rate, and respiratory rate in patients undergoing ophthalmic surgery.

  3. Evaluation of the influence of acquisition and reconstruction parameters for 16-row multidetector CT on coronary calcium scoring using a stationary and dynamic cardiac phantom.

    PubMed

    Begemann, Philipp G C; van Stevendaal, Udo; Koester, Ralph; Mahnken, Andreas H; Koops, Andreas; Adam, Gerhard; Grass, Michael; Nolte-Ernsting, Claus

    2007-08-01

    A calcium-scoring phantom with hydroxyapatite-filled cylindrical holes (0.5 to 4 mm) was used. High-resolution scans were performed for an accuracy baseline. The phantom was mounted to a moving heart phantom. Non-moving data with the implementation of an ECG-signal were acquired for different pitches (0.2/0.3), heart rates (60/80/95 bpm) and collimations (16 x 0.75/16 x 1.5 mm). Images were reconstructed with a cone-beam multi-cycle algorithm at a standard thickness/increment of 3 mm/1.5 mm and the thinnest possible thickness (0.8/0.4 and 2/1). Subsequently, ECG-gated moving calcium-scoring phantom data were acquired. The calcium volume and Agatston score were measured. The temporal resolution and reconstruction cycles were calculated. High-resolution scans determine the calcium volume with a high accuracy (mean overestimation, 0.8%). In the non-moving measurements, the volume underestimation ranged from about 6% (16 x 0.75 mm; 0.8/0.4 mm) to nearly 25% (16 x 1.5 mm; 3/1.5 mm). Moving scans showed increased measurement errors depending on the reconstructed RR interval, collimation, pitch, heart rate and gantry rotation time. Also, a correlation with the temporal resolution could be found. The reliability of calcium-scoring results can be improved with the use of a narrower collimation, a lower pitch and the reconstruction of thinner images, resulting in higher patient doses. The choice of the correct cardiac phase within the RR interval is essential to minimize measurement errors.

  4. Higher locus coeruleus MRI contrast is associated with lower parasympathetic influence over heart rate variability

    PubMed Central

    Mather, Mara; Yoo, Hyun Joo; Clewett, David V.; Lee, Tae-Ho; Greening, Steven G.; Ponzio, Allison; Min, Jungwon; Thayer, Julian F.

    2017-01-01

    The locus coeruleus (LC) is a key node of the sympathetic nervous system and suppresses parasympathetic activity that would otherwise increase heart rate variability. In the current study, we examined whether LC-MRI contrast reflecting neuromelanin accumulation in the LC was associated with high-frequency heart rate variability (HF-HRV), a measure reflecting parasympathetic influences on the heart. Recent evidence indicates that neuromelanin, a byproduct of catecholamine metabolism, accumulates in the LC through young and mid adulthood, suggesting that LC-MRI contrast may be a useful biomarker of individual differences in habitual LC activation. We found that, across younger and older adults, greater LC-MRI contrast was negatively associated with HF-HRV during fear conditioning and spatial detection tasks. This correlation was not accounted for by individual differences in age or anxiety. These findings indicate that individual differences in LC structure relate to key cardiovascular parameters. PMID:28215623

  5. Echocardiographic assessment of right ventricular function in routine practice: Which parameters are useful to predict one-year outcome in advanced heart failure patients with dilated cardiomyopathy?

    PubMed

    Kawata, Takayuki; Daimon, Masao; Kimura, Koichi; Nakao, Tomoko; Lee, Seitetsu L; Hirokawa, Megumi; Kato, Tomoko S; Watanabe, Masafumi; Yatomi, Yutaka; Komuro, Issei

    2017-10-01

    Right ventricular (RV) function has recently gained attention as a prognostic predictor of outcome even in patients who have left-sided heart failure. Since several conventional echocardiographic parameters of RV systolic function have been proposed, our aim was to determine if any of these parameters (tricuspid annular plane systolic excursion: TAPSE, tissue Doppler derived systolic tricuspid annular motion velocity: S', fractional area change: FAC) are associated with outcome in advanced heart failure patients with dilated cardiomyopathy (DCM). We retrospectively enrolled 68 DCM patients, who were New York Heart Association (NYHA) Class III or IV and had a left ventricular (LV) ejection fraction <35%. All patients were undergoing evaluation for heart transplantation or management of heart failure. Primary outcomes were defined as LV assist device implantation or cardiac death within one year. Thirty-nine events occurred (5 deaths, 32 LV assist devices implanted). Univariate analysis showed that age, systolic blood pressure, heart rate, NYHA functional class IV, plasma brain natriuretic peptide concentration, intravenous inotrope use, left atrial volume index, and FAC were associated with outcome, whereas TAPSE and S' were not. Receiver-operating characteristic curve analysis showed that the optimal FAC cut-off value to identify patients with an event was <26.7% (area under the curve=0.74). The event-free rate determined by Kaplan-Meier analysis was significantly higher in patients with FAC≥26.7% than in those with FAC<26.7% (log-lank, p=0.0003). Moreover, the addition of FAC<26.7% improved the prognostic utility of a model containing clinical variables and conventional echocardiographic indexes. FAC may provide better prognostic information than TAPSE or S' in advanced heart failure patients with DCM. Copyright © 2017 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  6. Reliability of Heart Rate Variability Analysis by Using Electrocardiogram Recorded Unrestrainedly from an Automobile Steering-Wheel

    NASA Astrophysics Data System (ADS)

    Osaka, Motohisa; Murata, Hiroshige; Tateoka, Katsuhiko; Katoh, Takao

    2007-07-01

    Some cases of traffic accidents are assumed to be due to the occurrences of cardiac events during driving, which are thought to be induced by imbalance of autonomic nervous activities. These can be measured by analyzing heart rate variability. Therefore, we developed a new system of steering-wheel electrocardiogram with a soft-ware to remove noises. We compared the trends of sympathetic and parasympathetic nerve activities measured from the steering-wheel electrocardiograms with those recorded simultaneously from chest leads. For each parameter of instantaneous heart rate, low- or high-frequency component of heart rate variability in all the cases, the trend from the steering-wheel electrocardiogram resembled that from the chest-lead electrocardiogram. In 3 of 7 subjects, the trend of LF/HF showed a strong relationship between the steering-wheel electrocardiogram and the chest-lead electrocardiogram. Our system will open doors to a new strategy to keep a driver out of a risk by notifying it while driving.

  7. [Effects of flunarizine and vitamin C on hemodynamics in rat heart subjected to ischemia-reperfusion].

    PubMed

    Xian, Y; Lan, T; Wang, Y

    1998-09-01

    Langendorff perfusion isolated rat heart was subjected to total global ischemia (coronary flow rate is equal to zero) for 10 minutes and reperfusion for 15 minutes. The heart rate (HR), left ventricular developed pressure (LVDP), coronary flow rate (CFR), electrocardiogram (ECG) and the effects of calcium antagonist-flunarizine (FNZ) and/or oxygen free radical scavenger--vitamine C on the above parameters were observed. The results showed that FNZ dilated coronary vessel (P < 0.01) and had a slight negative chronotropic effect, but it had no effect on LVP. Vitamine C did not affect HR, LVP and CFR. The recovery of the product of HR and LVDP-Rate Pressure Product (RPP) in the FNZ + Vit. C group, Vit. C group and FNZ group was significantly higher than that in the control group (P < 0.05) at ten minutes reperfusion. All the results suggest that FNZ and Vit. C may improve the recovery of heart function after reperfusion.

  8. Exhaled CO2 Parameters as a Tool to Assess Ventilation-Perfusion Mismatching during Neonatal Resuscitation in a Swine Model of Neonatal Asphyxia

    PubMed Central

    Li, Elliott Shang-shun; Cheung, Po-Yin; O'Reilly, Megan; LaBossiere, Joseph; Lee, Tze-Fun; Cowan, Shaun; Bigam, David L.; Schmölzer, Georg Marcus

    2016-01-01

    Background End-tidal CO2 (ETCO2), partial pressure of exhaled CO2 (PECO2), and volume of expired CO2 (VCO2) can be continuously monitored non-invasively to reflect pulmonary ventilation and perfusion status. Although ETCO2 ≥14mmHg has been shown to be associated with return of an adequate heart rate in neonatal resuscitation and quantifying the PECO2 has the potential to serve as an indicator of resuscitation quality, there is little information regarding capnometric measurement of PECO2 and ETCO2 in detecting return of spontaneous circulation (ROSC) and survivability in asphyxiated neonates receiving cardiopulmonary resuscitation (CPR). Methods Seventeen newborn piglets were anesthetized, intubated, instrumented, and exposed to 45-minute normocapnic hypoxia followed by apnea to induce asphyxia. Protocolized resuscitation was initiated when heart rate decreased to 25% of baseline. Respiratory and hemodynamic parameters including ETCO2, PECO2, VCO2, heart rate, cardiac output, and carotid artery flow were continuously measured and analyzed. Results There were no differences in respiratory and hemodynamic parameters between surviving and non-surviving piglets prior to CPR. Surviving piglets had significantly higher ETCO2, PECO2, VCO2, cardiac index, and carotid artery flow values during CPR compared to non-surviving piglets. Conclusion Surviving piglets had significantly better respiratory and hemodynamic parameters during resuscitation compared to non-surviving piglets. In addition to optimizing resuscitation efforts, capnometry can assist by predicting outcomes of newborns requiring chest compressions. PMID:26766424

  9. [The maximum heart rate in the exercise test: the 220-age formula or Sheffield's table?].

    PubMed

    Mesquita, A; Trabulo, M; Mendes, M; Viana, J F; Seabra-Gomes, R

    1996-02-01

    To determine in the maximum cardiac rate in exercise test of apparently healthy individuals may be more properly estimated through 220-age formula (Astrand) or the Sheffield table. Retrospective analysis of clinical history and exercises test of apparently healthy individuals submitted to cardiac check-up. Sequential sampling of 170 healthy individuals submitted to cardiac check-up between April 1988 and September 1992. Comparison of maximum cardiac rate of individuals studied by the protocols of Bruce and modified Bruce, in interrupted exercise test by fatigue, and with the estimated values by the formulae: 220-age versus Sheffield table. The maximum cardiac heart rate is similar with both protocols. This parameter in normal individuals is better predicted by the 220-age formula. The theoretic maximum cardiac heart rate determined by 220-age formula should be recommended for a healthy, and for this reason the Sheffield table has been excluded from our clinical practice.

  10. The effect of foot reflexology on physiologic parameters and mechanical ventilation weaning time in patients undergoing open-heart surgery: A clinical trial study.

    PubMed

    Ebadi, Abbas; Kavei, Parastoo; Moradian, Seyyed Tayyeb; Saeid, Yaser

    2015-08-01

    The aim of this study was to investigate the efficacy of foot reflexology on physiological parameters and mechanical ventilation weaning time in patients undergoing open-heart surgery. This was a double blind three-group randomized controlled trial. Totally, 96 patients were recruited and randomly allocated to the experimental, placebo, and the control groups. Study groups respectively received foot reflexology, simple surface touching, and the routine care of the study setting. Physiological parameters (pulse rate, respiratory rate, systolic and diastolic blood pressures, mean arterial pressure, percutaneous oxygen saturation) and weaning time were measured. The study groups did not differ significantly in terms of physiological parameters (P value > 0.05). However, the length of weaning time in the experimental group was significantly shorter than the placebo and the control groups (P value < 0.05). The study findings demonstrated the efficiency of foot reflexology in shortening the length of weaning time. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Heart rate and heart rate variability response to the transpiration of vortex-water by Begonia Eliator plants to the air in an office during visual display terminal work.

    PubMed

    Johansson, Benny

    2008-10-01

    This study explores the effects of vortex-water transpired from indoor greenery to office air, in relation to heart rate and heart rate variability during exposure to an electromagnetic field (EMF) from a visual display terminal (VDT). The study followed a randomized prospective single group cross-over design. Fifty (50) healthy volunteers, seated in any ordinary working posture in front of a VDT. Electrocardiography was measured in five 10-minute sequential tests. The VDT was turned off during the first test and switched on for the subsequent four tests. During tests 3 and 4, one of two Begonia Eliator plants, irrigated with either tap water or vortex-rotated (active) tap water during growth, was placed adjacent to the VDT. Heart rate, heart rate variability (HRV) and power spectral density (PSD) were analyzed. The heart rate was unchanged at the start of EMF exposure. The time domain measurements indicated a significant decrease in heart rate and a significant increase in HRV, accompanied by higher vagal tone in the presence, and finally in the absence, of the active plant. PSD parameters revealed significantly higher total power, as well as an increase in low frequencies (LF) and high frequencies (HF) in the condition induced by the active plant as well as after its removal. Very low frequencies (VLF) increased at EMF exposure whereas normally HF power decreased, accompanied by a rise in LF power and LF/HF ratio. HF power was higher at exposure to the active compared to the control plant. Spectral power density diagrams revealed an intensified spectral power band at frequencies of around 0.1 Hz at the condition of both plants, indicating systemic autonomic stability. The findings suggest that the parasympathetic response was associated with reduced heart rate, implicating restoration and maintenance of metabolic energy resources mediated by an involuntary adaptation to active plant-related stimuli.

  12. [Monitoring of occupational activities under the risk of heat stress: use of mathematical models in the prediction of physiological parameters].

    PubMed

    Terzi, R; Catenacci, G; Marcaletti, G

    1985-01-01

    Some authors proposed mathematical models that, starting from standardized conditions of environmental microclimate parameters, thermal impedance of the clothing, and energetic expenditure allowed the forecast of the body temperature and heart rate variations in respect to the basal values in subjects standing in the same environment. In the present work we verify the usefulness of these models applied to the working tasks characterized by standardized job made under unfavourable thermal conditions. In subject working in an electric power station the values of the body temperature and heart rate are registered and compared with the values obtained by the application of the studied models. The results are discussed in view of the practical use.

  13. Smart Multi-Level Tool for Remote Patient Monitoring Based on a Wireless Sensor Network and Mobile Augmented Reality

    PubMed Central

    González, Fernando Cornelio Jimènez; Villegas, Osslan Osiris Vergara; Ramírez, Dulce Esperanza Torres; Sánchez, Vianey Guadalupe Cruz; Domínguez, Humberto Ochoa

    2014-01-01

    Technological innovations in the field of disease prevention and maintenance of patient health have enabled the evolution of fields such as monitoring systems. One of the main advances is the development of real-time monitors that use intelligent and wireless communication technology. In this paper, a system is presented for the remote monitoring of the body temperature and heart rate of a patient by means of a wireless sensor network (WSN) and mobile augmented reality (MAR). The combination of a WSN and MAR provides a novel alternative to remotely measure body temperature and heart rate in real time during patient care. The system is composed of (1) hardware such as Arduino microcontrollers (in the patient nodes), personal computers (for the nurse server), smartphones (for the mobile nurse monitor and the virtual patient file) and sensors (to measure body temperature and heart rate), (2) a network layer using WiFly technology, and (3) software such as LabView, Android SDK, and DroidAR. The results obtained from tests show that the system can perform effectively within a range of 20 m and requires ten minutes to stabilize the temperature sensor to detect hyperthermia, hypothermia or normal body temperature conditions. Additionally, the heart rate sensor can detect conditions of tachycardia and bradycardia. PMID:25230306

  14. Smart multi-level tool for remote patient monitoring based on a wireless sensor network and mobile augmented reality.

    PubMed

    González, Fernando Cornelio Jiménez; Villegas, Osslan Osiris Vergara; Ramírez, Dulce Esperanza Torres; Sánchez, Vianey Guadalupe Cruz; Domínguez, Humberto Ochoa

    2014-09-16

    Technological innovations in the field of disease prevention and maintenance of patient health have enabled the evolution of fields such as monitoring systems. One of the main advances is the development of real-time monitors that use intelligent and wireless communication technology. In this paper, a system is presented for the remote monitoring of the body temperature and heart rate of a patient by means of a wireless sensor network (WSN) and mobile augmented reality (MAR). The combination of a WSN and MAR provides a novel alternative to remotely measure body temperature and heart rate in real time during patient care. The system is composed of (1) hardware such as Arduino microcontrollers (in the patient nodes), personal computers (for the nurse server), smartphones (for the mobile nurse monitor and the virtual patient file) and sensors (to measure body temperature and heart rate), (2) a network layer using WiFly technology, and (3) software such as LabView, Android SDK, and DroidAR. The results obtained from tests show that the system can perform effectively within a range of 20 m and requires ten minutes to stabilize the temperature sensor to detect hyperthermia, hypothermia or normal body temperature conditions. Additionally, the heart rate sensor can detect conditions of tachycardia and bradycardia.

  15. Cardiorespiratory response to exercise after renal sympathetic denervation in patients with resistant hypertension.

    PubMed

    Ukena, Christian; Mahfoud, Felix; Kindermann, Ingrid; Barth, Christine; Lenski, Matthias; Kindermann, Michael; Brandt, Mathias C; Hoppe, Uta C; Krum, Henry; Esler, Murray; Sobotka, Paul A; Böhm, Michael

    2011-09-06

    This study sought to investigate the effects of interventional renal sympathetic denervation (RD) on cardiorespiratory response to exercise. RD reduces blood pressure at rest in patients with resistant hypertension. We enrolled 46 patients with therapy-resistant hypertension as extended investigation of the Symplicity HTN-2 (Renal Denervation With Uncontrolled Hypertension) trial. Thirty-seven patients underwent bilateral RD and 9 patients were assigned to the control group. Cardiopulmonary exercise tests were performed at baseline and 3-month follow-up. In the RD group, compared with baseline examination, blood pressure at rest and at maximum exercise after 3 months was significantly reduced by 31 ± 13/9 ± 13 mm Hg (p < 0.0001) and by 21 ± 20/5 ± 14 mm Hg (p < 0.0001), respectively. Achieved work rate increased by 5 ± 13 W (p = 0.029) whereas peak oxygen uptake remained unchanged. Blood pressure 2 min after exercise was significantly reduced by 29 ± 17/8 ± 15 mm Hg (p < 0.001 for systolic blood pressure; p = 0.002 for diastolic blood pressure). Heart rate at rest decreased after RD (4 ± 11 beats/min; p = 0.028), whereas maximum heart rate and heart rate increase during exercise were not different. Heart rate recovery improved significantly by 4 ± 7 beats/min after renal denervation (p = 0.009). In the control group, there were no significant changes in blood pressure, heart rate, maximum work rate, or ventilatory parameters after 3 months. RD reduces blood pressure during exercise without compromising chronotropic competence in patients with resistant hypertension. Heart rate at rest decreased and heart rate recovery improved after the procedure. (Renal Denervation With Uncontrolled Hypertension; [Symplicity HTN-2]; NCT00888433). Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  16. Nocturnal heart rate variability in 1-year-old infants analyzed by using the Least Square Cosine Spectrum Method.

    PubMed

    Kochiya, Yuko; Hirabayashi, Akari; Ichimaru, Yuhei

    2017-09-16

    To evaluate the dynamic nature of nocturnal heart rate variability, RR intervals recorded with a wearable heart rate sensor were analyzed using the Least Square Cosine Spectrum Method. Six 1-year-old infants participated in the study. A wearable heart rate sensor was placed on their chest to measure RR intervals and 3-axis acceleration. Heartbeat time series were analyzed for every 30 s using the Least Square Cosine Spectrum Method, and an original parameter to quantify the regularity of respiratory-related heart rate rhythm was extracted and referred to as "RA (RA-COSPEC: Respiratory Area obtained by COSPEC)." The RA value is higher when a cosine curve is fitted to the original data series. The time sequential changes of RA showed cyclic changes with significant rhythm during the night. The mean cycle length of RA was 70 ± 15 min, which is shorter than young adult's cycle in our previous study. At the threshold level of RA greater than 3, the HR was significantly decreased compared with the RA value less than 3. The regularity of heart rate rhythm showed dynamic changes during the night in 1-year-old infants. Significant decrease of HR at the time of higher RA suggests the increase of parasympathetic activity. We suspect that the higher RA reflects the regular respiratory pattern during the night. This analysis system may be useful for quantitative assessment of regularity and dynamic changes of nocturnal heart rate variability in infants.

  17. VANADIUM EXPOSURE ALTERS SPONTANEOUS BEAT RATE AND GENE EXPRESSION OF CULTURED CARDIAC MYOCYTES

    EPA Science Inventory

    Ambient air pollution particulate matter (PM) exposure is associated with increased morbidity and mortality. Recent toxicological studies report PM-induced changes in a number of cardiac parameters, including heart rate variability, arrhythmias, repolarization, and internal defib...

  18. A motion-tolerant approach for monitoring SpO2 and heart rate using photoplethysmography signal with dual frame length processing and multi-classifier fusion.

    PubMed

    Fan, Feiyi; Yan, Yuepeng; Tang, Yongzhong; Zhang, Hao

    2017-12-01

    Monitoring pulse oxygen saturation (SpO 2 ) and heart rate (HR) using photoplethysmography (PPG) signal contaminated by a motion artifact (MA) remains a difficult problem, especially when the oximeter is not equipped with a 3-axis accelerometer for adaptive noise cancellation. In this paper, we report a pioneering investigation on the impact of altering the frame length of Molgedey and Schuster independent component analysis (ICAMS) on performance, design a multi-classifier fusion strategy for selecting the PPG correlated signal component, and propose a novel approach to extract SpO 2 and HR readings from PPG signal contaminated by strong MA interference. The algorithm comprises multiple stages, including dual frame length ICAMS, a multi-classifier-based PPG correlated component selector, line spectral analysis, tree-based HR monitoring, and post-processing. Our approach is evaluated by multi-subject tests. The root mean square error (RMSE) is calculated for each trial. Three statistical metrics are selected as performance evaluation criteria: mean RMSE, median RMSE and the standard deviation (SD) of RMSE. The experimental results demonstrate that a shorter ICAMS analysis window probably results in better performance in SpO 2 estimation. Notably, the designed multi-classifier signal component selector achieved satisfactory performance. The subject tests indicate that our algorithm outperforms other baseline methods regarding accuracy under most criteria. The proposed work can contribute to improving the performance of current pulse oximetry and personal wearable monitoring devices. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Power spectral analysis of heart rate in hyperthyroidism.

    PubMed

    Cacciatori, V; Bellavere, F; Pezzarossa, A; Dellera, A; Gemma, M L; Thomaseth, K; Castello, R; Moghetti, P; Muggeo, M

    1996-08-01

    The aim of the present study was to evaluate the impact of hyperthyroidism on the cardiovascular system by separately analyzing the sympathetic and parasympathetic influences on heart rate. Heart rate variability was evaluated by autoregressive power spectral analysis. This method allows a reliable quantification of the low frequency (LF) and high frequency (HF) components of the heart rate power spectral density; these are considered to be under mainly sympathetic and pure parasympathetic control, respectively. In 10 newly diagnosed untreated hyperthyroid patients with Graves' disease, we analyzed power spectral density of heart rate cyclic variations at rest, while lying, and while standing. In addition, heart rate variations during deep breathing, lying and standing, and Valsalva's maneuver were analyzed. The results were compared to those obtained from 10 age-, sex-, and body mass index-matched control subjects. In 8 hyperthyroid patients, the same evaluation was repeated after the induction of stable euthyroidism by methimazole. Heart rate power spectral analysis showed a sharp reduction of HF components in hyperthyroid subjects compared to controls [lying, 13.3 +/- 4.1 vs. 32.0 +/- 5.6 normalized units (NU; P < 0.01); standing, 6.0 +/- 2.7 vs. 15.0 +/- 4.0 NU (P < 0.01); mean +/- SEM]. On the other hand components were comparable in the 2 groups (lying, 64.0 +/- 6.9 vs. 62.0 +/- 6.5 NU; standing, 77.0 +/- 6.5 vs. 78.0 +/- 5.4 NU). Hence, the LF/HF ratio, which is considered an index of sympathovagal balance, was increased in hyperthyroid subjects while both lying (11.3 +/- 4.5 vs. 3.5 +/- 1.1; P < 0.05) and standing (54.0 +/- 12.6 vs. 9.8 +/- 2.6; P < 0.02). This parameter was positively correlated with both T3 (r = 0.61; P < 0.05) and free T4 (r = 0.63; P < 0.05) serum levels. Among traditional cardiovascular autonomic tests, the reflex response of heart rate during lying to standing was significantly lower in hyperthyroid patients than in controls (1.12 +/- 0.03 vs. 1.31 +/- 0.04; P < 0.002). No statistically significant difference in reflex responses between the two groups was found in deep breathing or Valsalva's maneuver. In the 8 patients reexamined after methimazole treatment, we observed complete normalization of altered cardiovascular parameters, with slight predominance of the vagal component compared with controls. These results suggest that thyroid hormone excess may determine reduced parasympathetic activity and, thus, a relative hypersympathetic tone.

  20. Effects of active recovery on autonomic and haemodynamic responses after aerobic exercise.

    PubMed

    Soares, Antonio H G; Oliveira, Tiago P; Cavalcante, Bruno R; Farah, Breno Q; Lima, Aluísio H R A; Cucato, Gabriel G; Cardoso, Crivaldo G; Ritti-Dias, Raphael M

    2017-01-01

    The aim of this study was to examine the effect of active recovery on autonomic and haemodynamic responses after exercise in healthy adults. Nineteen healthy young male individuals underwent two experimental sessions: exercise with active recovery (AR) and exercise with passive recovery (PR). The exercise sessions comprised three phases: warm-up (5 min), exercise phase (cycle ergometer, 30 min, intensity between 60 and 70% of the heart rate reserve) and recovery (5 min). In the AR, the subjects remained cycling in the recovery phase at intensity between 30% and 35% of heart rate reserve, while in the PR, the subjects stopped the exercise after finishing the exercise phase. Blood pressure and heart rate were measured before and over the 30 min after the interventions. There were no differences for systolic and diastolic blood pressures, heart rate and rate pressure product between active and passive recovery sessions. Also, all heart rate variability parameters changed similarly after exercise with passive or active recovery sessions. In summary, exercise with active recovery does not affect the autonomic and haemodynamic responses after moderate-intensity aerobic exercise in healthy young male individuals. © 2015 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  1. Stress, workload and physiology demand during extravehicular activity: a pilot study.

    PubMed

    Rai, Balwant; Kaur, Jasdeep; Foing, Bernard H

    2012-06-01

    Extravehicular activity (EVA), such as exercise performed under unique environmental conditions, is essential for supporting daily living in weightlessness and for further space exploration like long Mars mission. The study was planned stress, workload, and physiological demands of simulated Mars exploration. In this study, the six-person crew lived (24 hours) for 14 days during a short-term stay at the Mars Desert Research Station. The heart rates, salivary cortisol, workload, peak oxygen uptake or maximal aerobic capacity of the crew are measured before, during and after an EVA. Data for heart rate showed the same trend as peak oxygen uptake or maximal aerobic capacity, with a maximal increase to 85% of peak. The rating of subscale showed a significant increase in EVA as compared to run. Salivary cortisol levels and heart rates were increased in both groups, although significant increased of cortisol levels and heart rates more in EVA as compared to hill running crew members. Further study is required on large scale taken into account of limitations of this study and including other physiological and psychological parameters in Mars analog environment.

  2. Reliability of the Parabola Approximation Method in Heart Rate Variability Analysis Using Low-Sampling-Rate Photoplethysmography.

    PubMed

    Baek, Hyun Jae; Shin, JaeWook; Jin, Gunwoo; Cho, Jaegeol

    2017-10-24

    Photoplethysmographic signals are useful for heart rate variability analysis in practical ambulatory applications. While reducing the sampling rate of signals is an important consideration for modern wearable devices that enable 24/7 continuous monitoring, there have not been many studies that have investigated how to compensate the low timing resolution of low-sampling-rate signals for accurate heart rate variability analysis. In this study, we utilized the parabola approximation method and measured it against the conventional cubic spline interpolation method for the time, frequency, and nonlinear domain variables of heart rate variability. For each parameter, the intra-class correlation, standard error of measurement, Bland-Altman 95% limits of agreement and root mean squared relative error were presented. Also, elapsed time taken to compute each interpolation algorithm was investigated. The results indicated that parabola approximation is a simple, fast, and accurate algorithm-based method for compensating the low timing resolution of pulse beat intervals. In addition, the method showed comparable performance with the conventional cubic spline interpolation method. Even though the absolute value of the heart rate variability variables calculated using a signal sampled at 20 Hz were not exactly matched with those calculated using a reference signal sampled at 250 Hz, the parabola approximation method remains a good interpolation method for assessing trends in HRV measurements for low-power wearable applications.

  3. Reproducibility of Heart Rate Variability Is Parameter and Sleep Stage Dependent.

    PubMed

    Herzig, David; Eser, Prisca; Omlin, Ximena; Riener, Robert; Wilhelm, Matthias; Achermann, Peter

    2017-01-01

    Objective: Measurements of heart rate variability (HRV) during sleep have become increasingly popular as sleep could provide an optimal state for HRV assessments. While sleep stages have been reported to affect HRV, the effect of sleep stages on the variance of HRV parameters were hardly investigated. We aimed to assess the variance of HRV parameters during the different sleep stages. Further, we tested the accuracy of an algorithm using HRV to identify a 5-min segment within an episode of slow wave sleep (SWS, deep sleep). Methods: Polysomnographic (PSG) sleep recordings of 3 nights of 15 healthy young males were analyzed. Sleep was scored according to conventional criteria. HRV parameters of consecutive 5-min segments were analyzed within the different sleep stages. The total variance of HRV parameters was partitioned into between-subjects variance, between-nights variance, and between-segments variance and compared between the different sleep stages. Intra-class correlation coefficients of all HRV parameters were calculated for all sleep stages. To identify an SWS segment based on HRV, Pearson correlation coefficients of consecutive R-R intervals (rRR) of moving 5-min windows (20-s steps). The linear trend was removed from the rRR time series and the first segment with rRR values 0.1 units below the mean rRR for at least 10 min was identified. A 5-min segment was placed in the middle of such an identified segment and the corresponding sleep stage was used to assess the accuracy of the algorithm. Results: Good reproducibility within and across nights was found for heart rate in all sleep stages and for high frequency (HF) power in SWS. Reproducibility of low frequency (LF) power and of LF/HF was poor in all sleep stages. Of all the 5-min segments selected based on HRV data, 87% were accurately located within SWS. Conclusions: SWS, a stable state that, in contrast to waking, is unaffected by internal and external factors, is a reproducible state that allows reliable determination of heart rate, and HF power, and can satisfactorily be detected based on R-R intervals, without the need of full PSG. Sleep may not be an optimal condition to assess LF power and LF/HF power ratio.

  4. Reproducibility of Heart Rate Variability Is Parameter and Sleep Stage Dependent

    PubMed Central

    Herzig, David; Eser, Prisca; Omlin, Ximena; Riener, Robert; Wilhelm, Matthias; Achermann, Peter

    2018-01-01

    Objective: Measurements of heart rate variability (HRV) during sleep have become increasingly popular as sleep could provide an optimal state for HRV assessments. While sleep stages have been reported to affect HRV, the effect of sleep stages on the variance of HRV parameters were hardly investigated. We aimed to assess the variance of HRV parameters during the different sleep stages. Further, we tested the accuracy of an algorithm using HRV to identify a 5-min segment within an episode of slow wave sleep (SWS, deep sleep). Methods: Polysomnographic (PSG) sleep recordings of 3 nights of 15 healthy young males were analyzed. Sleep was scored according to conventional criteria. HRV parameters of consecutive 5-min segments were analyzed within the different sleep stages. The total variance of HRV parameters was partitioned into between-subjects variance, between-nights variance, and between-segments variance and compared between the different sleep stages. Intra-class correlation coefficients of all HRV parameters were calculated for all sleep stages. To identify an SWS segment based on HRV, Pearson correlation coefficients of consecutive R-R intervals (rRR) of moving 5-min windows (20-s steps). The linear trend was removed from the rRR time series and the first segment with rRR values 0.1 units below the mean rRR for at least 10 min was identified. A 5-min segment was placed in the middle of such an identified segment and the corresponding sleep stage was used to assess the accuracy of the algorithm. Results: Good reproducibility within and across nights was found for heart rate in all sleep stages and for high frequency (HF) power in SWS. Reproducibility of low frequency (LF) power and of LF/HF was poor in all sleep stages. Of all the 5-min segments selected based on HRV data, 87% were accurately located within SWS. Conclusions: SWS, a stable state that, in contrast to waking, is unaffected by internal and external factors, is a reproducible state that allows reliable determination of heart rate, and HF power, and can satisfactorily be detected based on R-R intervals, without the need of full PSG. Sleep may not be an optimal condition to assess LF power and LF/HF power ratio. PMID:29367845

  5. High Throughput Microplate Respiratory Measurements Using Minimal Quantities Of Isolated Mitochondria

    PubMed Central

    Rogers, George W.; Brand, Martin D.; Petrosyan, Susanna; Ashok, Deepthi; Elorza, Alvaro A.; Ferrick, David A.; Murphy, Anne N.

    2011-01-01

    Recently developed technologies have enabled multi-well measurement of O2 consumption, facilitating the rate of mitochondrial research, particularly regarding the mechanism of action of drugs and proteins that modulate metabolism. Among these technologies, the Seahorse XF24 Analyzer was designed for use with intact cells attached in a monolayer to a multi-well tissue culture plate. In order to have a high throughput assay system in which both energy demand and substrate availability can be tightly controlled, we have developed a protocol to expand the application of the XF24 Analyzer to include isolated mitochondria. Acquisition of optimal rates requires assay conditions that are unexpectedly distinct from those of conventional polarography. The optimized conditions, derived from experiments with isolated mouse liver mitochondria, allow multi-well assessment of rates of respiration and proton production by mitochondria attached to the bottom of the XF assay plate, and require extremely small quantities of material (1–10 µg of mitochondrial protein per well). Sequential measurement of basal, State 3, State 4, and uncoupler-stimulated respiration can be made in each well through additions of reagents from the injection ports. We describe optimization and validation of this technique using isolated mouse liver and rat heart mitochondria, and apply the approach to discover that inclusion of phosphatase inhibitors in the preparation of the heart mitochondria results in a specific decrease in rates of Complex I-dependent respiration. We believe this new technique will be particularly useful for drug screening and for generating previously unobtainable respiratory data on small mitochondrial samples. PMID:21799747

  6. Music close to one's heart: heart rate variability with music, diagnostic with e-bra and smartphone

    NASA Astrophysics Data System (ADS)

    Hegde, Shantala; Kumar, Prashanth S.; Rai, Pratyush; Mathur, Gyanesh N.; Varadan, Vijay K.

    2012-04-01

    Music is a powerful elicitor of emotions. Emotions evoked by music, through autonomic correlates have been shown to cause significant modulation of parameters like heart rate and blood pressure. Consequently, Heart Rate Variability (HRV) analysis can be a powerful tool to explore evidence based therapeutic functions of music and conduct empirical studies on effect of musical emotion on heart function. However, there are limitations with current studies. HRV analysis has produced variable results to different emotions evoked via music, owing to variability in the methodology and the nature of music chosen. Therefore, a pragmatic understanding of HRV correlates of musical emotion in individuals listening to specifically chosen music whilst carrying out day to day routine activities is needed. In the present study, we aim to study HRV as a single case study, using an e-bra with nano-sensors to record heart rate in real time. The e-bra developed previously, has several salient features that make it conducive for this study- fully integrated garment, dry electrodes for easy use and unrestricted mobility. The study considers two experimental conditions:- First, HRV will be recorded when there is no music in the background and second, when music chosen by the researcher and by the subject is playing in the background.

  7. Microwave influence on the isolated heart function. 1: Effect of modulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pakhomov, A.G.; Dubovick, B.V.; Degtyariov, I.G.

    1995-09-01

    Dependence of the microwave effect on modulation parameters (pulse width, duty ratio, and peak intensity) was studied in an isolated frog auricle preparation. The rate and amplitude of spontaneous auricle twitches were measured during and after a 2 min exposure to 915 or 885 MHz microwaves and were compared to preexposure values. The studied ranges of modulation parameters were: pulse width, 10{sup {minus}6}--10{sup {minus}2} s; duty ratio, 7:100000, and peak specific absorption rate, 100--3,000 W/kg. Combinations of the parameters were chosen by chance, and about 400 various exposure regimes were tested. The experiments established that no regime was effective unlessmore » the average microwave power was high enough to induce preparation heating (0.1--0.4 C). The twitch rate instantly increased, and the amplitude decreased, as the temperature rose; similar changes could be induced by equivalent conventional heating. the data provide evidence that the effect of short-term microwave exposure on the isolated heart pacemaker and contractile functions depends on pulse modulation just as much as modulation determines the average absorbed power. These functions demonstrated no specific dependence on exposure parameters such as frequency or power windows.« less

  8. Heart Sound Biometric System Based on Marginal Spectrum Analysis

    PubMed Central

    Zhao, Zhidong; Shen, Qinqin; Ren, Fangqin

    2013-01-01

    This work presents a heart sound biometric system based on marginal spectrum analysis, which is a new feature extraction technique for identification purposes. This heart sound identification system is comprised of signal acquisition, pre-processing, feature extraction, training, and identification. Experiments on the selection of the optimal values for the system parameters are conducted. The results indicate that the new spectrum coefficients result in a significant increase in the recognition rate of 94.40% compared with that of the traditional Fourier spectrum (84.32%) based on a database of 280 heart sounds from 40 participants. PMID:23429515

  9. Structural and Practical Identifiability Issues of Immuno-Epidemiological Vector-Host Models with Application to Rift Valley Fever.

    PubMed

    Tuncer, Necibe; Gulbudak, Hayriye; Cannataro, Vincent L; Martcheva, Maia

    2016-09-01

    In this article, we discuss the structural and practical identifiability of a nested immuno-epidemiological model of arbovirus diseases, where host-vector transmission rate, host recovery, and disease-induced death rates are governed by the within-host immune system. We incorporate the newest ideas and the most up-to-date features of numerical methods to fit multi-scale models to multi-scale data. For an immunological model, we use Rift Valley Fever Virus (RVFV) time-series data obtained from livestock under laboratory experiments, and for an epidemiological model we incorporate a human compartment to the nested model and use the number of human RVFV cases reported by the CDC during the 2006-2007 Kenya outbreak. We show that the immunological model is not structurally identifiable for the measurements of time-series viremia concentrations in the host. Thus, we study the non-dimensionalized and scaled versions of the immunological model and prove that both are structurally globally identifiable. After fixing estimated parameter values for the immunological model derived from the scaled model, we develop a numerical method to fit observable RVFV epidemiological data to the nested model for the remaining parameter values of the multi-scale system. For the given (CDC) data set, Monte Carlo simulations indicate that only three parameters of the epidemiological model are practically identifiable when the immune model parameters are fixed. Alternatively, we fit the multi-scale data to the multi-scale model simultaneously. Monte Carlo simulations for the simultaneous fitting suggest that the parameters of the immunological model and the parameters of the immuno-epidemiological model are practically identifiable. We suggest that analytic approaches for studying the structural identifiability of nested models are a necessity, so that identifiable parameter combinations can be derived to reparameterize the nested model to obtain an identifiable one. This is a crucial step in developing multi-scale models which explain multi-scale data.

  10. The Effect of Live Classical Piano Music on the Vital Signs of Patients Undergoing Ophthalmic Surgery

    PubMed Central

    Camara, Jorge G.; Ruszkowski, Joseph M.; Worak, Sandra R.

    2008-01-01

    Context Music and surgery. Objective To determine the effect of live classical piano music on vital signs of patients undergoing ophthalmic surgery. Design Retrospective case series. Setting and Patients 203 patients who underwent various ophthalmologic procedures in a period during which a piano was present in the operating room of St. Francis Medical Center. [Note: St. Francis Medical Center has recently been renamed Hawaii Medical Center East.] Intervention Demographic data, surgical procedures, and the vital signs of 203 patients who underwent ophthalmic procedures were obtained from patient records. Blood pressure, heart rate, and respiratory rate measured in the preoperative holding area were compared with the same parameters taken in the operating room, with and without exposure to live piano music. A paired t-test was used for statistical analysis. Main outcome measure Mean arterial pressure, heart rate, and respiratory rate. Results 115 patients who were exposed to live piano music showed a statistically significant decrease in mean arterial blood pressure, heart rate, and respiratory rate in the operating room compared with their vital signs measured in the preoperative holding area (P < .0001). The control group of 88 patients not exposed to live piano music showed a statistically significant increase in mean arterial blood pressure (P < .0002) and heart rate and respiratory rate (P < .0001). Conclusion Live classical piano music lowered the blood pressure, heart rate, and respiratory rate in patients undergoing ophthalmic surgery. PMID:18679538

  11. Mathematical modelling of the maternal cardiovascular system in the three stages of pregnancy.

    PubMed

    Corsini, Chiara; Cervi, Elena; Migliavacca, Francesco; Schievano, Silvia; Hsia, Tain-Yen; Pennati, Giancarlo

    2017-09-01

    In this study, a mathematical model of the female circulation during pregnancy is presented in order to investigate the hemodynamic response to the cardiovascular changes associated with each trimester of pregnancy. First, a preliminary lumped parameter model of the circulation of a non-pregnant female was developed, including the heart, the systemic circulation with a specific block for the uterine district and the pulmonary circulation. The model was first tested at rest; then heart rate and vascular resistances were individually varied to verify the correct response to parameter alterations characterising pregnancy. In order to simulate hemodynamics during pregnancy at each trimester, the main changes applied to the model consisted in reducing vascular resistances, and simultaneously increasing heart rate and ventricular wall volumes. Overall, reasonable agreement was found between model outputs and in vivo data, with the trends of the cardiac hemodynamic quantities suggesting correct response of the heart model throughout pregnancy. Results were reported for uterine hemodynamics, with flow tracings resembling typical Doppler velocity waveforms at each stage, including pulsatility indexes. Such a model may be used to explore the changes that happen during pregnancy in female with cardiovascular diseases. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  12. A novel handheld device for use in remote patient monitoring of heart failure patients--design and preliminary validation on healthy subjects.

    PubMed

    Pollonini, Luca; Rajan, Nithin O; Xu, Shuai; Madala, Sridhar; Dacso, Clifford C

    2012-04-01

    Remote patient monitoring (RPM) holds great promise for reducing the burden of congestive heart failure (CHF). Improved sensor technology and effective predictive algorithms can anticipate sudden decompensation events. Enhanced telemonitoring systems would promote patient independence and facilitate communication between patients and their physicians. We report the development of a novel hand-held device, called Blue Box, capable of collecting and wirelessly transmitting key cardiac parameters derived from three integrated biosensors: 2 lead electrocardiogram (ECG), photoplethysmography and bioelectrical impedance (bioimpedance). Blue Box measurements include time intervals between consecutive ECG R-waves (RR interval), time duration of the ECG complex formed by the Q, R and S waves (QRS duration), bioimpedance, heart rate and systolic time intervals. In this study, we recruited 24 healthy subjects to collect several parameters measured by Blue Box and assess their value in correlating with cardiac output measured with Echo-Doppler. Linear correlation between the heart rate measured with Blue Box and cardiac output from Echo-Doppler had a group average correlation coefficient of 0.80. We found that systolic time intervals did not improve the model significantly. However, STIs did inversely correlate with increasing workloads.

  13. Linear and nonlinear measures of fetal heart rate patterns evaluated on very short fetal magnetocardiograms.

    PubMed

    Moraes, Eder Rezende; Murta, Luiz Otavio; Baffa, Oswaldo; Wakai, Ronald T; Comani, Silvia

    2012-10-01

    We analyzed the effectiveness of linear short- and long-term variability time domain parameters, an index of sympatho-vagal balance (SDNN/RMSSD) and entropy in differentiating fetal heart rate patterns (fHRPs) on the fetal heart rate (fHR) series of 5, 3 and 2 min duration reconstructed from 46 fetal magnetocardiograms. Gestational age (GA) varied from 21 to 38 weeks. FHRPs were classified based on the fHR standard deviation. In sleep states, we observed that vagal influence increased with GA, and entropy significantly increased (decreased) with GA (SDNN/RMSSD), demonstrating that a prevalence of vagal activity with autonomous nervous system maturation may be associated with increased sleep state complexity. In active wakefulness, we observed a significant negative (positive) correlation of short-term (long-term) variability parameters with SDNN/RMSSD. ANOVA statistics demonstrated that long-term irregularity and standard deviation of normal-to-normal beat intervals (SDNN) best differentiated among fHRPs. Our results confirm that short- and long-term variability parameters are useful to differentiate between quiet and active states, and that entropy improves the characterization of sleep states. All measures differentiated fHRPs more effectively on very short HR series, as a result of the fMCG high temporal resolution and of the intrinsic timescales of the events that originate the different fHRPs.

  14. Comparison of HRV parameters derived from photoplethysmography and electrocardiography signals.

    PubMed

    Jeyhani, Vala; Mahdiani, Shadi; Peltokangas, Mikko; Vehkaoja, Antti

    2015-01-01

    Heart rate variability (HRV) has become a useful tool in analysis of cardiovascular system in both research and clinical fields. HRV has been also used in other applications such as stress level estimation in wearable devices. HRV is normally obtained from ECG as the time interval of two successive R waves. Recently PPG has been proposed as an alternative for ECG in HRV analysis to overcome some difficulties in measurement of ECG. In addition, PPG-HRV is also used in some commercial devices such as modern optical wrist-worn heart rate monitors. However, some researches have shown that PPG is not a surrogate for heart rate variability analysis. In this work, HRV analysis was applied on beat-to-beat intervals obtained from ECG and PPG in 19 healthy male subjects. Some important HRV parameters were calculated from PPG-HRV and ECG-HRV. Maximum of PPG and its second derivative were considered as two methods for obtaining the beat-to-beat signals from PPG and the results were compared with those achieved from ECG-HRV. Our results show that the smallest error happens in SDNN and SD2 with relative error of 2.46% and 2%, respectively. The most affected parameter is pNN50 with relative error of 29.89%. In addition, in our trial, using the maximum of PPG gave better results than its second derivative.

  15. Effect of Mobile Phone Radiofrequency Electromagnetic Fields on.

    PubMed

    Umar, Z U; Abubakar, M B; Ige, J; Igbokwe, U V; Mojiminiyi, F B O; Isezuo, S A

    2014-12-29

    Since cell phones emit radiofrequency electromagnetic fields (EMFs), this study tested the hypothesis that cell phones placed near the heart may interfere with the electrical rhythm of the heart or affect the blood pressure. Following informed consent, eighteen randomly selected apparently healthy male volunteers aged 21.44 ± 0.53 years had their blood pressure, pulse rates and ECG measured before and after acute exposure to a cell phone. The ECG parameters obtained were: heart rate (HR), QRS complex duration (QRS), PR interval (PR) and Corrected QT interval (QTc). Results are presented as mean ± SEM. Statistical analyses were done using two-tailed paired t test for blood pressure and pulse rate data and one way ANOVA with a post hoc Tukey test for the ECG data. P<0.05 was considered statistically significant. The blood pressure and pulse rates before and after exposure to the cell phone showed no significant difference. The ECG parameters (HR: beats/min, QRS:ms, PR:ms and QTc respectively) did not differ before (66.33 ± 2.50, 91.78 ± 1.36, 151.67 ± 5.39 and 395.44 ± 4.96), during (66.33 ± 2.40, 91.11 ± 1.61, 153.67 ± 5.06 and 394.33 ± 4.05) and after calls (67.22 ± 2.77, 91.11 ± 1.67, 157.44 ± 4.46 and 396.56 ± 4.93) compared to baseline (67.17 ± 2.19, 94.33 ± 1.57, 150.56 ± 4.93 and 399.56 ± 3.88). These results suggest that acute exposure to EMFs from cell phones placed near the heart may not interfere with the electrical activity of the heart or blood pressure in healthy individuals.

  16. Heart rate variability and turbulence in hyperthyroidism before, during, and after treatment.

    PubMed

    Osman, Faizel; Franklyn, Jayne A; Daykin, Jacqueline; Chowdhary, Saqib; Holder, Roger L; Sheppard, Michael C; Gammage, Michael D

    2004-08-15

    Patients with subclinical and treated overt hyperthyroidism have an excess vascular mortality rate. Several symptoms and signs in overt hyperthyroidism suggest abnormality of cardiac autonomic function that may account in part for this excess mortality rate, but few studies have examined cardiac autonomic function in untreated and treated hyperthyroidism. We assessed heart rate turbulence (HRT) and time-domain parameters of heart rate variability in a large, unselected cohort of patients with overt hyperthyroidism referred to our thyroid clinic (n = 259) and compared findings with a group of normal subjects with euthyroidism (n = 440). These measures were also evaluated during antithyroid therapy (when serum-free thyroxine and triiodothyronine concentrations returned to normal but thyrotropin remained suppressed (i.e., subclinical hyperthyroidism, n = 110) and when subjects were rendered clinically and biochemically euthyroid (normal serum thyrotropin, free thyroxine and triiodothyronine concentrations, n = 219). We found that overall measures of heart rate variability and those specific for cardiac vagal modulation were attenuated in patients with overt hyperthyroidism compared with normal subjects; measurements of overall heart rate variability remained low in those with low levels of serum thyrotropin but returned to normal in patients with biochemical euthyroidism. Measurements of HRT (onset and slope) were also decreased in patients with overt hyperthyroidism, but HRT slope returned to normal values with antithyroid treatment. This study is the first to evaluate HRT in overt and treated hyperthyroidism.

  17. Heart Rate Variability Reflects the Natural History of Physiological Development in Healthy Children and Is Not Associated with Quality of Life

    PubMed Central

    Seifert, Georg; Calaminus, Gabriele; Wiener, Andreas; Cysarz, Dirk

    2014-01-01

    Background Quality of life (QoL), being the sum expression of diverse influencing factors, is not easy to determine. A clinically relevant option would be to identify and measure quality of life on the basis of physiological parameters which correlate plausibly and statistically with psychometrically measured QoL. Analysis of heart rate variability (HRV) offers readily measurable physiological parameters which could be of use here. A correlation of HRV with both course of disease and QoL has been reported in patients with chronic illness. Various psychometric instruments have been developed for use in paediatric oncology. The aim of this study was to obtain data on HRV and QoL and their correlations, initially in healthy children. Methods Holter ECG and quality of life were examined in 160 children and adolescents (72 male) aged between 8 and 18 years. QoL was determined with the established questionnaire PEDQoL. Standard parameters of HRV from the frequency domain were calculated and correlated with QoL domains using Spearman (nonparametric) correlation analysis. Results Minor but significant associations were revealed only with regard to the PEDQoL domain “autonomy” on the one hand and heart rate and HRV (e.g. MRR, MRRn, MRRd, HRV_ULF, SDNN) parameters which evidently reflect distinct physiological functions on the other. Conclusions In healthy children and adolescents we have a first indication that there is a correlation between parameters of HRV and QoL. However, to a greater extent, HRV reflects associated physiological processes of the autonomic nervous system. A higher correlation is more likely to be found in chronically ill children. PMID:24625571

  18. Identifying increased risk of post-infarct people with diabetes using multi-lag Tone-Entropy analysis.

    PubMed

    Karmakar, Chandan; Jelinek, Herbert; Khandoker, Ahsan; Tulppo, Mikko; Makikallio, Timo; Kiviniemi, Antti; Huikuri, Heikki; Palaniswami, Marimuthu

    2012-01-01

    Diabetes mellitus is associated with multi-organ system dysfunction. One of the key causative factors is the increased blood sugar level that leads to an increase in free radical activity and organ damage including the cardiovascular and nervous system. Heart rhythm is extrinsically modulated by the autonomic nervous system and cardiac autonomic neuropathy or dysautonomia has been shown to lead to sudden cardiac death in people with diabetes due to the decrease in heart rate variability (HRV). Current algorithms for determining HRV describe only beat-to-beat variation and therefore do not consider the ability of a heart beat to influence a train of succeeding beats. Therefore mortality risk analysis based on HRV has often not been able to discern the presence of an increased risk. This study used a novel innovation of the tone-entropy algorithm by incorporating increased lag intervals and found that both the sympatho-vagal balance and total activity changed at larger lag intervals. Tone-Entropy was found to be better risk identifier of cardiac mortality in people with diabetes at lags higher than one and best at lag seven.

  19. Incorporating oximeter analyses to investigate synchronies in heart rate while teaching and learning about race

    NASA Astrophysics Data System (ADS)

    Amat, Arnau; Zapata, Corinna; Alexakos, Konstantinos; Pride, Leah D.; Paylor-Smith, Christian; Hernandez, Matthew

    2016-09-01

    In this paper, we look closely at two events selected through event-oriented inquiry that were part of a classroom presentation on race. The first event was a provocative discussion about Mark Twain's ( Pudd'nhead Wilson, Harper, New York, 1899) and passing for being White. The other was a discussion on the use of the N-word. Grounded in authentic inquiry, we use ethnographic narrative, cogenerative dialogues, and video and oximeter data analyses as part of a multi-ontological approach for studying emotions. Statistical analysis of oximeter data shows statistically significant heart rate synchrony among two of the coteachers during their presentations, providing evidence of emotional synchrony, resonance, and social and emotional contagion.

  20. A usability study of a mobile monitoring system for congestive heart failure patients.

    PubMed

    Svagård, I; Austad, H O; Seeberg, T; Vedum, J; Liverud, A; Mathiesen, B M; Keller, B; Bendixen, O C; Osborne, P; Strisland, F

    2014-01-01

    Sensor-based monitoring of congestive heart-failure (CHF) patients living at home can improve quality of care, detect exacerbations of disease at an earlier stage and motivate the patient for better self care. This paper reports on a usability study of the ESUMS system that provides continuous measurements of heart rate, activity, upper body posture and skin temperature via a sensor belt and a smartphone as patient terminal. Five CHF patients were included in the trial, all recently discharged from hospital. The nurses experienced continuous heart rate, activity and posture monitoring as useful and objective tools that helped them in their daily assessment of patient health. They also saw the system as an important educational tool to help patients gain insight into their own condition. Three patients liked that they could have a view of their own physiological and activity data, however the smartphones used in the study turned out to be too complicated for the patients to operate. A smartphone is built to be a multi-purpose device, and this may (conceptually and practically) be incompatible with the patients' demands for ease of use.

  1. Ivabradine, a novel heart rate slower: is it a sword of double blades in patients with idiopathic dilated cardiomyopathy?

    PubMed

    Rayan, Mona; Tawfik, Mazen; Alabd, Ali; Gamal, Amr

    2011-08-01

    To prospectively assess the safety and efficacy of ivabradine in patients with idiopathic dilated cardiomyopathy. We included 35 patients with idiopathic dilated cardiomyopathy with an ejection fraction (EF) <40% and heart rate >70 beats/min despite optimal medical therapy, according to the international guidelines in this prospective, non-randomized, single-arm, open-label safety study. Ivabradine was used as an add-on therapy to the maximally tolerated b-blocker in an increasing titrated dose till a target dose of 15 mg/day or resting heart rate of 60 beats/min for 3 months. During follow-up period the safety, patient tolerance and efficacy of this drug were assessed. All patients underwent 12-lead resting electrocardiography and Holter monitoring at inclusion and after 3 months. Statistical analysis was accomplished using paired t-test and Pearson correlation analysis. We found a significant reduction in the resting heart rate by a mean of 25.9 ± 9.4%, without a significant change of blood pressure. There was no prolongation of PR, QTc or QRS durations. Ventricular ectopic activity showed significant reduction (p<0.001). There was a significant correlation between the resting heart rate, NYHA and left ventricular ejection fraction (p<0.001 for both). One patient developed photopsia and decompensation was observed in another patient. Ivabradine is a safe and effective drug in reducing resting heart rate, improving NYHA functional class without undesirable effects on conduction parameters or ectopic activity.

  2. Time- and frequency-domain parameters of heart rate variability and sympathetic skin response in Parkinson's disease.

    PubMed

    Maetzler, Walter; Karam, Marie; Berger, Monika Fruhmann; Heger, Tanja; Maetzler, Corina; Ruediger, Heinz; Bronzova, Juliana; Lobo, Patricia Pita; Ferreira, Joaquim J; Ziemssen, Tjalf; Berg, Daniela

    2015-03-01

    The autonomic nervous system (ANS) is regularly affected in Parkinson's disease (PD). Information on autonomic dysfunction can be derived from e.g. altered heart rate variability (HRV) and sympathetic skin response (SSR). Such parameters can be quantified easily and measured repeatedly which might be helpful for evaluating disease progression and therapeutic outcome. In this 2-center study, HRV and SSR of 45 PD patients and 26 controls were recorded. HRV was measured during supine metronomic breathing and analyzed in time- and frequency-domains. SSR was evoked by repetitive auditory stimulation. Various ANS parameters were compared (1) between patients and healthy controls, (2) to clinical scales (Unified Parkinson's disease rating scale, Mini-Mental State Examination, Becks Depression Inventory), and (3) to disease duration. Root mean square of successive differences (RMSSD) and low frequency/high frequency (LF/HF) ratio differed significantly between PD and controls. Both, HRV and SSR parameters showed low or no association with clinical scores. Time-domain parameters tended to be affected already at early PD stages but did not consistently change with longer disease duration. In contrast, frequency-domain parameters were not altered in early PD phases but tended to be lower (LF, LF/HF ratio), respectively higher (HF) with increasing disease duration. This report confirms previous results of altered ANS parameters in PD. In addition, it suggests that (1) these ANS parameters are not relevantly associated with motor, behavioral, and cognitive changes in PD, (2) time-domain parameters are useful for the assessment of early PD, and (3) frequency-domain parameters are more closely associated with disease duration.

  3. A systematic review of prenatal screening for congenital heart disease by fetal electrocardiography.

    PubMed

    Verdurmen, Kim M J; Eijsvoogel, Noortje B; Lempersz, Carlijn; Vullings, Rik; Schroer, Christian; van Laar, Judith O E H; Oei, S Guid

    2016-11-01

    Congenital heart disease (CHD) is the most common severe congenital anomaly worldwide. Diagnosis early in pregnancy is important, but the detection rate by two-dimensional ultrasonography is only 65%-81%. To evaluate existing data on CHD and noninvasive abdominal fetal electrocardiography (ECG). A systematic review was performed through a search of the Cochrane Library, PubMed, and Embase for studies published up to April 2016 using the terms "congenital heart disease," "fetal electrocardiogram," and other similar keywords. Primary articles that described changes in fetal ECG among fetuses with CHD published in English were included. Outcomes of interest were changes in fetal ECG parameters observed for fetuses with congenital heart disease. Findings were reported descriptively. Only five studies described changes observed in the fetal electrocardiogram for fetuses with CHD, including heart rate, heart rate variability, and PR, QRS, and QT intervals. Fetal ECG reflects the intimate relationship between the cardiac nerve conduction system and the structural morphology of the heart. It seems particularly helpful in detecting the electrophysiological effects of cardiac anatomic defects (e.g. hypotrophy, hypertrophy, and conduction interruption). Fetal ECG might be a promising clinical tool to complement ultrasonography in the screening program for CHD. Copyright © 2016 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  4. Validation of Heart Rate Monitor Polar RS800 for Heart Rate Variability Analysis During Exercise.

    PubMed

    Hernando, David; Garatachea, Nuria; Almeida, Rute; Casajús, Jose A; Bailón, Raquel

    2018-03-01

    Hernando, D, Garatachea, N, Almeida, R, Casajús, JA, and Bailón, R. Validation of heart rate monitor Polar RS800 for heart rate variability analysis during exercise. J Strength Cond Res 32(3): 716-725, 2018-Heart rate variability (HRV) analysis during exercise is an interesting noninvasive tool to measure the cardiovascular response to the stress of exercise. Wearable heart rate monitors are a comfortable option to measure interbeat (RR) intervals while doing physical activities. It is necessary to evaluate the agreement between HRV parameters derived from the RR series recorded by wearable devices and those derived from an electrocardiogram (ECG) during dynamic exercise of low to high intensity. Twenty-three male volunteers performed an exercise stress test on a cycle ergometer. Subjects wore a Polar RS800 device, whereas ECG was also recorded simultaneously to extract the reference RR intervals. A time-frequency spectral analysis was performed to extract the instantaneous mean heart rate (HRM), and the power of low-frequency (PLF) and high-frequency (PHF) components, the latter centered on the respiratory frequency. Analysis was done in intervals of different exercise intensity based on oxygen consumption. Linear correlation, reliability, and agreement were computed in each interval. The agreement between the RR series obtained from the Polar device and from the ECG is high throughout the whole test although the shorter the RR is, the more differences there are. Both methods are interchangeable when analyzing HRV at rest. At high exercise intensity, HRM and PLF still presented a high correlation (ρ > 0.8) and excellent reliability and agreement indices (above 0.9). However, the PHF measurements from the Polar showed reliability and agreement coefficients around 0.5 or lower when the level of the exercise increases (for levels of O2 above 60%).

  5. Effects of chronic baroreceptor stimulation on the autonomic cardiovascular regulation in patients with drug-resistant arterial hypertension.

    PubMed

    Wustmann, Kerstin; Kucera, Jan P; Scheffers, Ingrid; Mohaupt, Markus; Kroon, Abraham A; de Leeuw, Peter W; Schmidli, Jürg; Allemann, Yves; Delacrétaz, Etienne

    2009-09-01

    In patients with drug-resistant hypertension, chronic electric stimulation of the carotid baroreflex is an investigational therapy for blood pressure reduction. We hypothesized that changes in cardiac autonomic regulation can be demonstrated in response to chronic baroreceptor stimulation, and we analyzed the correlation with blood pressure changes. Twenty-one patients with drug-resistant hypertension were prospectively included in a substudy of the Device Based Therapy in Hypertension Trial. Heart rate variability and heart rate turbulence were analyzed using 24-hour ECG. Recordings were obtained 1 month after device implantation with the stimulator off and after 3 months of chronic electric stimulation (stimulator on). Chronic baroreceptor stimulation decreased office blood pressure from 185+/-31/109+/-24 mm Hg to 154+/-23/95+/-16 mm Hg (P<0.0001/P=0.002). Mean heart rate decreased from 81+/-11 to 76+/-10 beats per minute(-1) (P=0.001). Heart rate variability frequency-domain parameters assessed using fast Fourier transformation (FFT; ratio of low frequency:high frequency: 2.78 versus 2.24 for off versus on; P<0.001) were significantly changed during stimulation of the carotid baroreceptor, and heart rate turbulence onset was significantly decreased (turbulence onset: -0.002 versus -0.015 for off versus on; P=0.004). In conclusion, chronic baroreceptor stimulation causes sustained changes in heart rate variability and heart rate turbulence that are consistent with inhibition of sympathetic activity and increase of parasympathetic activity in patients with drug-resistant systemic hypertension; these changes correlate with blood pressure reduction. Whether the autonomic modulation has favorable cardiovascular effects beyond blood pressure control should be investigated in further studies.

  6. The normal electrocardiogram of four species of conscious raptors.

    PubMed

    Talavera, J; Guzmán, M J; del Palacio, M J Fernández; Albert, A P; Bayón, A

    2008-02-01

    The aim of this study was to describe normal ECG patterns and values in four species of conscious raptors (Eurasian kestrel, Griffon vulture, Little owl, and Eurasian Eagle owl). Electrocardiograms were carried out in 75 conscious birds belonging to four species of raptors. Lead II waveforms were analysed to determine amplitudes and durations of waves and intervals. Morphologic patterns of P-QRS-T deflections were analysed in the six limb leads. Rhythm, heart rate, mean electrical axis, presence of Ta wave, ST slurring, and P-on-T phenomenon were also studied. The influence of species, body weight and heart rate in electrocardiographic variables were statistically analysed (P < 0.05). Sinus rhythm was present in all tracings, showing sinus arrhythmia in four cases. Ta wave was present in six tracings and P-on-T phenomenon in four. ST segment could be identified in all tracings, being mainly high above baseline. Significant differences between species were found for all the electrocardiographic parameters. The heart rate and body weight were also found to be a significant influence in most parameters. This study provides electrocardiographic data for four species of raptors that can be used to establish comparisons for clinical purposes.

  7. Influence of computer work under time pressure on cardiac activity.

    PubMed

    Shi, Ping; Hu, Sijung; Yu, Hongliu

    2015-03-01

    Computer users are often under stress when required to complete computer work within a required time. Work stress has repeatedly been associated with an increased risk for cardiovascular disease. The present study examined the effects of time pressure workload during computer tasks on cardiac activity in 20 healthy subjects. Heart rate, time domain and frequency domain indices of heart rate variability (HRV) and Poincaré plot parameters were compared among five computer tasks and two rest periods. Faster heart rate and decreased standard deviation of R-R interval were noted in response to computer tasks under time pressure. The Poincaré plot parameters showed significant differences between different levels of time pressure workload during computer tasks, and between computer tasks and the rest periods. In contrast, no significant differences were identified for the frequency domain indices of HRV. The results suggest that the quantitative Poincaré plot analysis used in this study was able to reveal the intrinsic nonlinear nature of the autonomically regulated cardiac rhythm. Specifically, heightened vagal tone occurred during the relaxation computer tasks without time pressure. In contrast, the stressful computer tasks with added time pressure stimulated cardiac sympathetic activity. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. [Effect of substance P on cardiac autonomic nervous function in rats].

    PubMed

    Deng, Lijun; Li, Jing; Yan, Fuping; Lu, Jie

    2009-12-01

    Forty SD rats were divided into 5 groups: control group, SP groups (5 microg/kg,10 microg/kg, 20 microg/kg) and spantide II plus SP group. An analysis of heart rate variability (HRV) was used to detect the changes of HRV parameters before and after intravenous injection of SP in order to investigate the effect of substance P on cardiac autonomic nervous function and the corresponding mechanism. (1) There were significant differences in most HRV parameters for the three different doses of SP. Mean heart period (MHP), absolute power of ultra-low frequency and high frequency band (APU, APH), total power (TPV) and ratio of power in ultra-low to high frequency band (RUH) increased, while mean heart rate (MHR) and chaos intensity (HCC) decreased during the 30 minutes. Each peak amplitude of HRV parameters went higher and showed up ahead of the upward doses of SP. (2) Significant change was seen in each of the parameters between spantide II plus SP group and high-dose SP group. These data idicate that, after intravenous injection of different doses of SP, both cardiac sympathetic nervous system activity and parasympathetic nervous system activity increase, and the function of cardiac autonomic nervous becomes instable and unbalanced. The effect of SP may be dose dependent, and it is possibly mediated by neurokinin-1(NK-1) receptor.

  9. Higher locus coeruleus MRI contrast is associated with lower parasympathetic influence over heart rate variability.

    PubMed

    Mather, Mara; Joo Yoo, Hyun; Clewett, David V; Lee, Tae-Ho; Greening, Steven G; Ponzio, Allison; Min, Jungwon; Thayer, Julian F

    2017-04-15

    The locus coeruleus (LC) is a key node of the sympathetic nervous system and suppresses parasympathetic activity that would otherwise increase heart rate variability. In the current study, we examined whether LC-MRI contrast reflecting neuromelanin accumulation in the LC was associated with high-frequency heart rate variability (HF-HRV), a measure reflecting parasympathetic influences on the heart. Recent evidence indicates that neuromelanin, a byproduct of catecholamine metabolism, accumulates in the LC through young and mid adulthood, suggesting that LC-MRI contrast may be a useful biomarker of individual differences in habitual LC activation. We found that, across younger and older adults, greater LC-MRI contrast was negatively associated with HF-HRV during fear conditioning and spatial detection tasks. This correlation was not accounted for by individual differences in age or anxiety. These findings indicate that individual differences in LC structure relate to key cardiovascular parameters. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. 21 CFR 868.2377 - Apnea monitor.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... breath. The apnea monitor also includes indirect methods of apnea detection such as monitoring of heart rate and other physiological parameters linked to the presence or absence of adequate respiration. (b...

  11. 21 CFR 868.2377 - Apnea monitor.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... breath. The apnea monitor also includes indirect methods of apnea detection such as monitoring of heart rate and other physiological parameters linked to the presence or absence of adequate respiration. (b...

  12. 21 CFR 868.2377 - Apnea monitor.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... breath. The apnea monitor also includes indirect methods of apnea detection such as monitoring of heart rate and other physiological parameters linked to the presence or absence of adequate respiration. (b...

  13. 21 CFR 868.2377 - Apnea monitor.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... breath. The apnea monitor also includes indirect methods of apnea detection such as monitoring of heart rate and other physiological parameters linked to the presence or absence of adequate respiration. (b...

  14. 21 CFR 868.2377 - Apnea monitor.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... breath. The apnea monitor also includes indirect methods of apnea detection such as monitoring of heart rate and other physiological parameters linked to the presence or absence of adequate respiration. (b...

  15. Classic electrocardiogram-based and mobile technology derived approaches to heart rate variability are not equivalent.

    PubMed

    Guzik, Przemyslaw; Piekos, Caroline; Pierog, Olivia; Fenech, Naiman; Krauze, Tomasz; Piskorski, Jaroslaw; Wykretowicz, Andrzej

    2018-05-01

    We compared classic ECG-derived versus a mobile approach to heart rate variability (HRV) measurement. 29 young adult healthy volunteers underwent a simultaneous recording of heart rate using an ECG and a chest heart rate monitor at supine rest, during mental stress and active standing. Mean RR interval, Standard Deviation of Normal-to-Normal (SDNN) of RR intervals, and Root Mean Square of the Successive Differences (RMSSD) between RR intervals were computed in 168 pairs of 5-minute epochs by in-house software on a PC (only sinus beats) and by mobile application "ELITEHRV" on a smartphone (no beat type identification). ECG analysis showed that 33.9% of the recordings contained at least one non-sinus beat or artefact, the mobile app did not report this. The mean RR intervals were significantly longer (p = 0.0378), while SDNN (p = 0.0001) and RMSSD (p = 0.0199) were smaller for the mobile approach. Measures of identical HRV parameters by ECG-based and mobile approaches are not equivalent. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Diurnal changes in the power spectral characteristics of eye movements and heart rate variability in the human fetus at term.

    PubMed

    Morokuma, S; Horimoto, N; Nakano, H

    2001-08-01

    It is well known that 1/f characteristics in power spectral patterns exist in various biological factors including heart rate variability. In the present study, we tried to elucidate the diurnal variation in spectral properties of eye movement and heart rate variability in the human fetus at term, via continuous 24-h observation of both these parameters. Studied were five uncomplicated fetuses at term. We observed eye movement and fetal heart rate (FHR) with real-time ultrasound and Doppler cardiotocograph, respectively, and analyzed the diurnal change in spectral properties, using the maximum entropy method. In four of five cases, the slope values of power spectra for both eye movement frequency and FHR, ranging approximately between 0.5 and 1.8, indicated diurnal variation, where the slopes tended to have high values during the day and low values at night. These findings suggest that, in the human fetus at term, eye movement and FHR are under the control of a common central mechanism, and this center changes its complexity as seen through diurnal rhythm.

  17. Body position and activity, but not heart rate, affect pump flows in patients with continuous-flow left ventricular assist devices.

    PubMed

    Muthiah, Kavitha; Gupta, Sunil; Otton, James; Robson, Desiree; Walker, Robyn; Tay, Andre; Macdonald, Peter; Keogh, Anne; Kotlyar, Eugene; Granger, Emily; Dhital, Kumud; Spratt, Phillip; Jansz, Paul; Hayward, Christopher S

    2014-08-01

    The aim of this study was to determine the contribution of pre-load and heart rate to pump flow in patients implanted with continuous-flow left ventricular assist devices (cfLVADs). Although it is known that cfLVAD pump flow increases with exercise, it is unclear if this increment is driven by increased heart rate, augmented intrinsic ventricular contraction, or enhanced venous return. Two studies were performed in patients implanted with the HeartWare HVAD. In 11 patients, paced heart rate was increased to approximately 40 beats/min above baseline and then down to approximately 30 beats/min below baseline pacing rate (in pacemaker-dependent patients). Ten patients underwent tilt-table testing at 30°, 60°, and 80° passive head-up tilt for 3 min and then for a further 3 min after ankle flexion exercise. This regimen was repeated at 20° passive head-down tilt. Pump parameters, noninvasive hemodynamics, and 2-dimensional echocardiographic measures were recorded. Heart rate alteration by pacing did not affect LVAD flows or LV dimensions. LVAD pump flow decreased from baseline 4.9 ± 0.6 l/min to approximately 4.5 ± 0.5 l/min at each level of head-up tilt (p < 0.0001 analysis of variance). With active ankle flexion, LVAD flow returned to baseline. There was no significant change in flow with a 20° head-down tilt with or without ankle flexion exercise. There were no suction events. Centrifugal cfLVAD flows are not significantly affected by changes in heart rate, but they change significantly with body position and passive filling. Previously demonstrated exercise-induced changes in pump flows may be related to altered loading conditions, rather than changes in heart rate. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  18. Clinical effects of carvedilol and trimetazidine for the treatmentof alcoholic myocardiopathy.

    PubMed

    Li, Hui; Liu, Fu-Yuan; Li, Xiao-Lan; Li, Xiao-Mei; Zhu, Lei

    2016-08-01

    The aim of the study was to compare the clinical effects of carvedilol and trimetazidine for the treatment of alcoholic cardiomyopathy. A total of 60 patients diagnosed with alcoholic cardiomyopathy were enrolled in the study. The patients were randomly divided into the carvedilol (n=20), trimetazidine (n=20) and control (n=20) groups. The patients in the control, carvedilol and trimetazidine groups were treated with conventional drugs, conventional drugs + carvedil and conventional drugs + trimetazidine respectively, for 12 weeks. The patients were compared for their heart functions [left ventricular ejection fraction (LVEF), C-reactive protein (CRP) and 6 min walking], heart rate, blood pressure and heart enlargement (cardiothoracic proportion and left ventricular diameter) before and after treatment. The parameters studied for heart functions, heart rate, blood pressure, heart enlargement, clinical effects before and after treatment were statistically insignificant (p>0.05). After treatment, the carvedilol and trimetazidine groups showed higher LVEF and CRP, longer walking distance in 6 min, as well as lower heart rate and blood pressure (both systolic and diastolic) compared to the control group. Similarly, the cardiothoracic proportion and left ventricular internal diameter for the carvedilol and trimetazidine groups was lower than those of the control group, with better clinical effects (p<0.05). In conclusion, the curative effects of the carvedilol and trimetazidine groups of alcoholic myocardiopathy similar. Both are safe agents that may improve the cardiac function and heart expansion of patients.

  19. Computerized system for assessing heart rate variability.

    PubMed

    Frigy, A; Incze, A; Brânzaniuc, E; Cotoi, S

    1996-01-01

    The principal theoretical, methodological and clinical aspects of heart rate variability (HRV) analysis are reviewed. This method has been developed over the last 10 years as a useful noninvasive method of measuring the activity of the autonomic nervous system. The main components and the functioning of the computerized rhythm-analyzer system developed by our team are presented. The system is able to perform short-term (maximum 20 minutes) time domain HRV analysis and statistical analysis of the ventricular rate in any rhythm, particularly in atrial fibrillation. The performances of our system are demonstrated by using the graphics (RR histograms, delta RR histograms, RR scattergrams) and the statistical parameters resulted from the processing of three ECG recordings. These recordings are obtained from a normal subject, from a patient with advanced heart failure, and from a patient with atrial fibrillation.

  20. A clinical decision-making mechanism for context-aware and patient-specific remote monitoring systems using the correlations of multiple vital signs.

    PubMed

    Forkan, Abdur Rahim Mohammad; Khalil, Ibrahim

    2017-02-01

    In home-based context-aware monitoring patient's real-time data of multiple vital signs (e.g. heart rate, blood pressure) are continuously generated from wearable sensors. The changes in such vital parameters are highly correlated. They are also patient-centric and can be either recurrent or can fluctuate. The objective of this study is to develop an intelligent method for personalized monitoring and clinical decision support through early estimation of patient-specific vital sign values, and prediction of anomalies using the interrelation among multiple vital signs. In this paper, multi-label classification algorithms are applied in classifier design to forecast these values and related abnormalities. We proposed a completely new approach of patient-specific vital sign prediction system using their correlations. The developed technique can guide healthcare professionals to make accurate clinical decisions. Moreover, our model can support many patients with various clinical conditions concurrently by utilizing the power of cloud computing technology. The developed method also reduces the rate of false predictions in remote monitoring centres. In the experimental settings, the statistical features and correlations of six vital signs are formulated as multi-label classification problem. Eight multi-label classification algorithms along with three fundamental machine learning algorithms are used and tested on a public dataset of 85 patients. Different multi-label classification evaluation measures such as Hamming score, F1-micro average, and accuracy are used for interpreting the prediction performance of patient-specific situation classifications. We achieved 90-95% Hamming score values across 24 classifier combinations for 85 different patients used in our experiment. The results are compared with single-label classifiers and without considering the correlations among the vitals. The comparisons show that multi-label method is the best technique for this problem domain. The evaluation results reveal that multi-label classification techniques using the correlations among multiple vitals are effective ways for early estimation of future values of those vitals. In context-aware remote monitoring this process can greatly help the doctors in quick diagnostic decision making. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  1. Physiological responses to the Coriolis illusion: effects of head position and vision.

    PubMed

    Westmoreland, David; Krell, Robert W; Self, Brian P

    2007-10-01

    Changes in sympathetic outflow during Type II spatial disorientation are well documented. In this study we investigated the influences of head position and eye state (open or closed) on sympathetic activation. There were 11 naive subjects (6 men, 5 women) who were tested in a General Aviation Trainer that accelerated at a subthreshold rate for 60 s until a constant angular velocity of 90 degrees x s(-1) was reached. Approximately 40 s later, subjects were instructed to tilt their heads along either the pitch or roll axis, stimulating a Coriolis illusion. Subjects reported the perceived intensity and duration of disorientation. Heart rate, heart rate variability, and electrodermal responses were recorded before, during, and after the period of disorientation. Each subject completed four trials, which were crossed combinations of head position and eye state. There were significant increases in heart rate and the electrodermal response during disorientation, but no significant change in heart rate variability. Head position had no significant effect on any physiological parameters or on the perceived intensity of disorientation; subjects reported a shorter duration of disorientation when the head was tilted into the roll versus the pitch axis. Eye state had no effect on heart rate, heart rate variability, or the intensity of disorientation, but the electrodermal response was somewhat greater, and the duration of disorientation shorter when eyes were open. The results suggest that head position and eye state (open or closed) do not need to be included as factors when investigating sympathetic outflow during a mild Coriolis illusion.

  2. Multi-objective optimization in quantum parameter estimation

    NASA Astrophysics Data System (ADS)

    Gong, BeiLi; Cui, Wei

    2018-04-01

    We investigate quantum parameter estimation based on linear and Kerr-type nonlinear controls in an open quantum system, and consider the dissipation rate as an unknown parameter. We show that while the precision of parameter estimation is improved, it usually introduces a significant deformation to the system state. Moreover, we propose a multi-objective model to optimize the two conflicting objectives: (1) maximizing the Fisher information, improving the parameter estimation precision, and (2) minimizing the deformation of the system state, which maintains its fidelity. Finally, simulations of a simplified ɛ-constrained model demonstrate the feasibility of the Hamiltonian control in improving the precision of the quantum parameter estimation.

  3. Long-term bradycardia caused by atrioventricular block can remodel the canine heart to detect the histamine H1 blocker terfenadine-induced torsades de pointes arrhythmias.

    PubMed

    Takahara, Akira; Sugiyama, Atsushi; Ishida, Yuko; Satoh, Yoshioki; Wang, Kai; Nakamura, Yuji; Hashimoto, Keitaro

    2006-03-01

    Although a second-generation histamine H(1) blocker terfenadine induced torsades de pointes (TdP) arrhythmias in patients via the blockade of a rapid component of delayed rectifier K(+) current (I(Kr)), such action of terfenadine has not been detected in previous animal models. We analysed the potential of the canine persistent atrioventricular block heart, a new in vivo proarrhythmia model, to detect a torsadogenic effect of terfenadine of an oral dose of 3 or 30 mg kg(-1). The doses can provide therapeutic to supra-therapeutic plasma concentrations as an anti-histamine. In 2 weeks of bradycardiac heart model, there were no significant changes in any of the electrocardiogram parameters after the administration of both doses of terfenadine. In 4-6 weeks of bradycardiac heart model, the low dose of terfenadine hardly affected any of the electrocardiogram parameters except that it induced TdP in one out of six animals. The high dose significantly decreased the atrial rate and ventricular rate, prolonged the QT interval, and induced TdP in five out of six animals. Moreover, temporal variability of repolarization increased after the high-dose administration. These results suggest that long-term bradycardia caused by atrioventricular block can remodel the canine heart to detect terfenadine-induced TdP.

  4. Linking Inflammation, Cardiorespiratory Variability, and Neural Control in Acute Inflammation via Computational Modeling

    PubMed Central

    Dick, Thomas E.; Molkov, Yaroslav I.; Nieman, Gary; Hsieh, Yee-Hsee; Jacono, Frank J.; Doyle, John; Scheff, Jeremy D.; Calvano, Steve E.; Androulakis, Ioannis P.; An, Gary; Vodovotz, Yoram

    2012-01-01

    Acute inflammation leads to organ failure by engaging catastrophic feedback loops in which stressed tissue evokes an inflammatory response and, in turn, inflammation damages tissue. Manifestations of this maladaptive inflammatory response include cardio-respiratory dysfunction that may be reflected in reduced heart rate and ventilatory pattern variabilities. We have developed signal-processing algorithms that quantify non-linear deterministic characteristics of variability in biologic signals. Now, coalescing under the aegis of the NIH Computational Biology Program and the Society for Complexity in Acute Illness, two research teams performed iterative experiments and computational modeling on inflammation and cardio-pulmonary dysfunction in sepsis as well as on neural control of respiration and ventilatory pattern variability. These teams, with additional collaborators, have recently formed a multi-institutional, interdisciplinary consortium, whose goal is to delineate the fundamental interrelationship between the inflammatory response and physiologic variability. Multi-scale mathematical modeling and complementary physiological experiments will provide insight into autonomic neural mechanisms that may modulate the inflammatory response to sepsis and simultaneously reduce heart rate and ventilatory pattern variabilities associated with sepsis. This approach integrates computational models of neural control of breathing and cardio-respiratory coupling with models that combine inflammation, cardiovascular function, and heart rate variability. The resulting integrated model will provide mechanistic explanations for the phenomena of respiratory sinus-arrhythmia and cardio-ventilatory coupling observed under normal conditions, and the loss of these properties during sepsis. This approach holds the potential of modeling cross-scale physiological interactions to improve both basic knowledge and clinical management of acute inflammatory diseases such as sepsis and trauma. PMID:22783197

  5. Linking Inflammation, Cardiorespiratory Variability, and Neural Control in Acute Inflammation via Computational Modeling.

    PubMed

    Dick, Thomas E; Molkov, Yaroslav I; Nieman, Gary; Hsieh, Yee-Hsee; Jacono, Frank J; Doyle, John; Scheff, Jeremy D; Calvano, Steve E; Androulakis, Ioannis P; An, Gary; Vodovotz, Yoram

    2012-01-01

    Acute inflammation leads to organ failure by engaging catastrophic feedback loops in which stressed tissue evokes an inflammatory response and, in turn, inflammation damages tissue. Manifestations of this maladaptive inflammatory response include cardio-respiratory dysfunction that may be reflected in reduced heart rate and ventilatory pattern variabilities. We have developed signal-processing algorithms that quantify non-linear deterministic characteristics of variability in biologic signals. Now, coalescing under the aegis of the NIH Computational Biology Program and the Society for Complexity in Acute Illness, two research teams performed iterative experiments and computational modeling on inflammation and cardio-pulmonary dysfunction in sepsis as well as on neural control of respiration and ventilatory pattern variability. These teams, with additional collaborators, have recently formed a multi-institutional, interdisciplinary consortium, whose goal is to delineate the fundamental interrelationship between the inflammatory response and physiologic variability. Multi-scale mathematical modeling and complementary physiological experiments will provide insight into autonomic neural mechanisms that may modulate the inflammatory response to sepsis and simultaneously reduce heart rate and ventilatory pattern variabilities associated with sepsis. This approach integrates computational models of neural control of breathing and cardio-respiratory coupling with models that combine inflammation, cardiovascular function, and heart rate variability. The resulting integrated model will provide mechanistic explanations for the phenomena of respiratory sinus-arrhythmia and cardio-ventilatory coupling observed under normal conditions, and the loss of these properties during sepsis. This approach holds the potential of modeling cross-scale physiological interactions to improve both basic knowledge and clinical management of acute inflammatory diseases such as sepsis and trauma.

  6. Right ventricular functional analysis utilizing first pass radionuclide angiography for pre-operative ventricular assist device planning: a multi-modality comparison.

    PubMed

    Avery, Ryan; Day, Kevin; Jokerst, Clinton; Kazui, Toshinobu; Krupinski, Elizabeth; Khalpey, Zain

    2017-10-10

    Advanced heart failure treated with a left ventricular assist device is associated with a higher risk of right heart failure. Many advanced heart failures patients are treated with an ICD, a relative contraindication to MRI, prior to assist device placement. Given this limitation, left and right ventricular function for patients with an ICD is calculated using radionuclide angiography utilizing planar multigated acquisition (MUGA) and first pass radionuclide angiography (FPRNA), respectively. Given the availability of MRI protocols that can accommodate patients with ICDs, we have correlated the findings of ventricular functional analysis using radionuclide angiography to cardiac MRI, the reference standard for ventricle function calculation, to directly correlate calculated ejection fractions between these modalities, and to also assess agreement between available echocardiographic and hemodynamic parameters of right ventricular function. A retrospective review from January 2012 through May 2014 was performed to identify advanced heart failure patients who underwent both cardiac MRI and radionuclide angiography for ventricular functional analysis. Nine heart failure patients (8 men, 1 woman; mean age of 57.0 years) were identified. The average time between the cardiac MRI and radionuclide angiography exams was 38.9 days (range: 1 - 119 days). All patients undergoing cardiac MRI were scanned using an institutionally approved protocol for ICD with no device-related complications identified. A retrospective chart review of each patient for cardiomyopathy diagnosis, clinical follow-up, and echocardiogram and right heart catheterization performed during evaluation was also performed. The 9 patients demonstrated a mean left ventricular ejection fraction (LVEF) using cardiac MRI of 20.7% (12 - 40%). Mean LVEF using MUGA was 22.6% (12 - 49%). The mean right ventricular ejection fraction (RVEF) utilizing cardiac MRI was 28.3% (16 - 43%), and the mean RVEF calculated by FPRNA was 32.6% (9 - 56%). The mean discrepancy for LVEF between cardiac MRI and MUGA was 4.1% (0 - 9%), and correlation of calculated LVEF using cardiac MRI and MUGA demonstrated an R of 0.9. The mean discrepancy for RVEF between cardiac MRI and FPRNA was 12.0% (range: 2 - 24%) with a moderate correlation (R = 0.5). The increased discrepancies for RV analysis were statistically significant using an unpaired t-test (t = 3.19, p = 0.0061). Echocardiogram parameters of RV function, including TAPSE and FAC, were for available for all 9 patients and agreement with cardiac MRI demonstrated a kappa statistic for TAPSE of 0.39 (95% CI of 0.06 - 0.72) and for FAC of 0.64 (95% of 0.21 - 1.00). Heart failure patients are increasingly requiring left ventricular assist device placement; however, definitive evaluation of biventricular function is required due to the increased mortality rate associated with right heart failure after assist device placement. Our results suggest that FPRNA only has a moderate correlation with reference standard RVEFs calculated using cardiac MRI, which was similar to calculated agreements between cardiac MRI and echocardiographic parameters of right ventricular function. Given the need for identification of patients at risk for right heart failure, further studies are warranted to determine a more accurate estimate of RVEF for heart failure patients during pre-operative ventricular assist device planning.

  7. Echocardiographic Parameters and Survival in Chagas Heart Disease with Severe Systolic Dysfunction

    PubMed Central

    Rassi, Daniela do Carmo; Vieira, Marcelo Luiz Campos; Arruda, Ana Lúcia Martins; Hotta, Viviane Tiemi; Furtado, Rogério Gomes; Rassi, Danilo Teixeira; Rassi, Salvador

    2014-01-01

    Background Echocardiography provides important information on the cardiac evaluation of patients with heart failure. The identification of echocardiographic parameters in severe Chagas heart disease would help implement treatment and assess prognosis. Objective To correlate echocardiographic parameters with the endpoint cardiovascular mortality in patients with ejection fraction < 35%. Methods Study with retrospective analysis of pre-specified echocardiographic parameters prospectively collected from 60 patients included in the Multicenter Randomized Trial of Cell Therapy in Patients with Heart Diseases (Estudo Multicêntrico Randomizado de Terapia Celular em Cardiopatias) - Chagas heart disease arm. The following parameters were collected: left ventricular systolic and diastolic diameters and volumes; ejection fraction; left atrial diameter; left atrial volume; indexed left atrial volume; systolic pulmonary artery pressure; integral of the aortic flow velocity; myocardial performance index; rate of increase of left ventricular pressure; isovolumic relaxation time; E, A, Em, Am and Sm wave velocities; E wave deceleration time; E/A and E/Em ratios; and mitral regurgitation. Results In the mean 24.18-month follow-up, 27 patients died. The mean ejection fraction was 26.6 ± 5.34%. In the multivariate analysis, the parameters ejection fraction (HR = 1.114; p = 0.3704), indexed left atrial volume (HR = 1.033; p < 0.0001) and E/Em ratio (HR = 0.95; p = 0.1261) were excluded. The indexed left atrial volume was an independent predictor in relation to the endpoint, and values > 70.71 mL/m2 were associated with a significant increase in mortality (log rank p < 0.0001). Conclusion The indexed left atrial volume was the only independent predictor of mortality in this population of Chagasic patients with severe systolic dysfunction. PMID:24553982

  8. Echocardiographic parameters and survival in Chagas heart disease with severe systolic dysfunction.

    PubMed

    Rassi, Daniela do Carmo; Vieira, Marcelo Luiz Campos; Arruda, Ana Lúcia Martins; Hotta, Viviane Tiemi; Furtado, Rogério Gomes; Rassi, Danilo Teixeira; Rassi, Salvador

    2014-03-01

    Echocardiography provides important information on the cardiac evaluation of patients with heart failure. The identification of echocardiographic parameters in severe Chagas heart disease would help implement treatment and assess prognosis. To correlate echocardiographic parameters with the endpoint cardiovascular mortality in patients with ejection fraction < 35%. Study with retrospective analysis of pre-specified echocardiographic parameters prospectively collected from 60 patients included in the Multicenter Randomized Trial of Cell Therapy in Patients with Heart Diseases (Estudo Multicêntrico Randomizado de Terapia Celular em Cardiopatias) - Chagas heart disease arm. The following parameters were collected: left ventricular systolic and diastolic diameters and volumes; ejection fraction; left atrial diameter; left atrial volume; indexed left atrial volume; systolic pulmonary artery pressure; integral of the aortic flow velocity; myocardial performance index; rate of increase of left ventricular pressure; isovolumic relaxation time; E, A, Em, Am and Sm wave velocities; E wave deceleration time; E/A and E/Em ratios; and mitral regurgitation. In the mean 24.18-month follow-up, 27 patients died. The mean ejection fraction was 26.6 ± 5.34%. In the multivariate analysis, the parameters ejection fraction (HR = 1.114; p = 0.3704), indexed left atrial volume (HR = 1.033; p < 0.0001) and E/Em ratio (HR = 0.95; p = 0.1261) were excluded. The indexed left atrial volume was an independent predictor in relation to the endpoint, and values > 70.71 mL/m2 were associated with a significant increase in mortality (log rank p < 0.0001). The indexed left atrial volume was the only independent predictor of mortality in this population of Chagasic patients with severe systolic dysfunction.

  9. Retinal Vein Occlusion in a Multi-Ethnic Asian Population: The Singapore Epidemiology of Eye Disease Study.

    PubMed

    Koh, Victor; Cheung, Carol Y; Li, Xiang; Tian, Dechao; Wang, Jie Jin; Mitchell, Paul; Cheng, Ching-Yu; Wong, Tien Y

    2016-01-01

    To describe the prevalence of retinal vein occlusion (RVO) and its risk factors in a multi-ethnic Asian population. This population-based study of 10,033 participants (75.7% response rate) included Chinese, Indian and Malay persons aged 40 years and older. A comprehensive ophthalmic examination, standardized interviews and laboratory blood tests were performed. Digital fundus photographs were assessed for presence of RVO following the definitions used in the Blue Mountains Eye Study. Regression analysis models were constructed to study the relationship between ocular and systemic factors and RVO. Age-specific prevalence rates of RVO were applied to project the number of people affected in Asia from 2013 to 2040. The overall crude prevalence of RVO was 0.72% (n = 71; 95% confidence interval, CI, 0.54-0.87%). The crude prevalence of RVO was similar in Chinese, Indian and Malay participants (p = 0.865). In multivariable regression models, significant risk factors of RVO included increased age (odds ratio, OR, 1.03, 95% CI 1.01-1.06), hypertension (OR 3.65, 95% CI 1.61-8.31), increased serum creatinine (OR 1.04, 95% CI 1.01-1.06, per 10 mmol/L increase), history of heart attack (OR 2.25, 95% CI 1.11-4.54) and increased total cholesterol (OR 1.31, 95% CI 1.07-1.59, per 1 mmol/L increase). None of the ocular parameters were associated with RVO. RVO is estimated to affect up to 16 and 21 million people in Asia by 2020 and 2040, respectively. RVO was detected in 0.72% of a multi-ethnic Asian population aged 40-80 years in Singapore. The significant systemic risk factors of RVO are consistent with studies in white populations.

  10. Promising effects of xanthine oxidase inhibition by allopurinol on autonomic heart regulation estimated by heart rate variability (HRV) analysis in rats exposed to hypoxia and hyperoxia

    PubMed Central

    Ziółkowski, Wiesław; Badtke, Piotr; Zajączkowski, Miłosz A.; Flis, Damian J.; Figarski, Adam; Smolińska-Bylańska, Maria; Wierzba, Tomasz H.

    2018-01-01

    Background It has long been suggested that reactive oxygen species (ROS) play a role in oxygen sensing via peripheral chemoreceptors, which would imply their involvement in chemoreflex activation and autonomic regulation of heart rate. We hypothesize that antioxidant affect neurogenic cardiovascular regulation through activation of chemoreflex which results in increased control of sympathetic mechanism regulating heart rhythm. Activity of xanthine oxidase (XO), which is among the major endogenous sources of ROS in the rat has been shown to increase during hypoxia promote oxidative stress. However, the mechanism of how XO inhibition affects neurogenic regulation of heart rhythm is still unclear. Aim The study aimed to evaluate effects of allopurinol-driven inhibition of XO on autonomic heart regulation in rats exposed to hypoxia followed by hyperoxia, using heart rate variability (HRV) analysis. Material and methods 16 conscious male Wistar rats (350 g): control-untreated (N = 8) and pretreated with Allopurinol-XO inhibitor (5 mg/kg, followed by 50 mg/kg), administered intraperitoneally (N = 8), were exposed to controlled hypobaric hypoxia (1h) in order to activate chemoreflex. The treatment was followed by 1h hyperoxia (chemoreflex suppression). Time-series of 1024 RR-intervals were extracted from 4kHz ECG recording for heart rate variability (HRV) analysis in order to calculate the following time-domain parameters: mean RR interval (RRi), SDNN (standard deviation of all normal NN intervals), rMSSD (square root of the mean of the squares of differences between adjacent NN intervals), frequency-domain parameters (FFT method): TSP (total spectral power) as well as low and high frequency band powers (LF and HF). At the end of experiment we used rat plasma to evaluate enzymatic activity of XO and markers of oxidative stress: protein carbonyl group and 8-isoprostane concentrations. Enzymatic activity of superoxide dismutase (SOD), catalase (CAT) and glutathione peroxidase (GPx) were measures in erythrocyte lysates. Results Allopurinol reduced oxidative stress which was the result of hypoxia/hyperoxia, as shown by decreased 8-isoprostane plasma concentration. XO inhibition did not markedly influence HRV parameters in standard normoxia. However, during hypoxia, as well as hyperoxia, allopurinol administration resulted in a significant increase of autonomic control upon the heart as shown by increased SDNN and TSP, with an increased vagal contribution (increased rMSSD and HF), whereas sympathovagal indexes (LF/HF, SDNN/rMSSD) remained unchanged. Conclusions Observed regulatory effects of XO inhibition did not confirm preliminary hypothesis which suggested that an antioxidant such as allopurinol might activate chemoreflex resulting in augmented sympathetic discharge to the heart. The HRV regulatory profile of XO inhibition observed during hypoxia as well as post-hypoxic hyperoxia corresponds to reported reduced risk of sudden cardiovascular events. Therefore our data provide a new argument for therapeutical use of allopurinol in hypoxic conditions. PMID:29432445

  11. Promising effects of xanthine oxidase inhibition by allopurinol on autonomic heart regulation estimated by heart rate variability (HRV) analysis in rats exposed to hypoxia and hyperoxia.

    PubMed

    Zajączkowski, Stanisław; Ziółkowski, Wiesław; Badtke, Piotr; Zajączkowski, Miłosz A; Flis, Damian J; Figarski, Adam; Smolińska-Bylańska, Maria; Wierzba, Tomasz H

    2018-01-01

    It has long been suggested that reactive oxygen species (ROS) play a role in oxygen sensing via peripheral chemoreceptors, which would imply their involvement in chemoreflex activation and autonomic regulation of heart rate. We hypothesize that antioxidant affect neurogenic cardiovascular regulation through activation of chemoreflex which results in increased control of sympathetic mechanism regulating heart rhythm. Activity of xanthine oxidase (XO), which is among the major endogenous sources of ROS in the rat has been shown to increase during hypoxia promote oxidative stress. However, the mechanism of how XO inhibition affects neurogenic regulation of heart rhythm is still unclear. The study aimed to evaluate effects of allopurinol-driven inhibition of XO on autonomic heart regulation in rats exposed to hypoxia followed by hyperoxia, using heart rate variability (HRV) analysis. 16 conscious male Wistar rats (350 g): control-untreated (N = 8) and pretreated with Allopurinol-XO inhibitor (5 mg/kg, followed by 50 mg/kg), administered intraperitoneally (N = 8), were exposed to controlled hypobaric hypoxia (1h) in order to activate chemoreflex. The treatment was followed by 1h hyperoxia (chemoreflex suppression). Time-series of 1024 RR-intervals were extracted from 4kHz ECG recording for heart rate variability (HRV) analysis in order to calculate the following time-domain parameters: mean RR interval (RRi), SDNN (standard deviation of all normal NN intervals), rMSSD (square root of the mean of the squares of differences between adjacent NN intervals), frequency-domain parameters (FFT method): TSP (total spectral power) as well as low and high frequency band powers (LF and HF). At the end of experiment we used rat plasma to evaluate enzymatic activity of XO and markers of oxidative stress: protein carbonyl group and 8-isoprostane concentrations. Enzymatic activity of superoxide dismutase (SOD), catalase (CAT) and glutathione peroxidase (GPx) were measures in erythrocyte lysates. Allopurinol reduced oxidative stress which was the result of hypoxia/hyperoxia, as shown by decreased 8-isoprostane plasma concentration. XO inhibition did not markedly influence HRV parameters in standard normoxia. However, during hypoxia, as well as hyperoxia, allopurinol administration resulted in a significant increase of autonomic control upon the heart as shown by increased SDNN and TSP, with an increased vagal contribution (increased rMSSD and HF), whereas sympathovagal indexes (LF/HF, SDNN/rMSSD) remained unchanged. Observed regulatory effects of XO inhibition did not confirm preliminary hypothesis which suggested that an antioxidant such as allopurinol might activate chemoreflex resulting in augmented sympathetic discharge to the heart. The HRV regulatory profile of XO inhibition observed during hypoxia as well as post-hypoxic hyperoxia corresponds to reported reduced risk of sudden cardiovascular events. Therefore our data provide a new argument for therapeutical use of allopurinol in hypoxic conditions.

  12. Tricaine (MS-222) is a safe anesthetic compound compared to benzocaine and pentobarbital to induce anesthesia in leopard frogs (Rana pipiens).

    PubMed

    Cakir, Yavuz; Strauch, Stephen M

    2005-01-01

    Tricaine (MS-222) is used commonly for sedation, immobilization, and anesthesia of poikilothermic animals. The anesthetic efficacy of different concentrations of MS-222 was compared to benzocaine and pentobarbital on the physiological changes, heart rate and ECG (electrocardiogram) parameters in the leopard frog, Rana pipiens. Loss of righting reflex (RR), loss of pain response (NR = nociceptor response) and recovery time were measured. Heart rate and ECG parameters were also tested before and during anesthesia. The time to loss of RR and NR decreased while recovery time markedly increased with the increasing concentration of MS-222. Benzocaine at 200 mg/l induced a rapid anesthesia, but all frogs needed resuscitation. Pentobarbital at 300 mg/l induced a slow anesthesia, however, all of the frogs also needed resuscitation. All anesthetics at the mentioned concentrations decreased heart rate significantly as well as altered the ECG parameters. All anesthetics prolonged the Q-T interval, and MS-222 at 800 mg/l and benzocaine at 200 mg/l were the most effective anesthetic concentrations in increasing the Q-T interval. Frogs anesthetized by benzocaine and pentobarbital and high concentrations of MS-222 required resuscitation due to hypoxia. Pentobarbital and benzocaine seem to be very effective compounds, but their safety margins are narrow because of ventilatory failure. Therefore, MS-222 at a concentration of 200 mg/l or less is highly recommended for leopard frogs because prolonged recovery, high mortality rate and significant ECG changes are observed with higher concentrations of MS-222.

  13. Evaluation of the influence of ayurvedic formulation (Ayushman-15) on psychopathology, heart rate variability and stress hormonal level in major depression (Vishada).

    PubMed

    Kishore, Ramakrishna K; Abhishekh, Hulegar A; Udupa, Kaviraja; Thirthalli, Jagadisha; Lavekar, Gandhidas S; Gangadhar, Bangalore N; Raju, Trichur R; Sathyaprabha, Talakad N

    2014-12-01

    Ayurveda (Indian-complimentary and alternative medicine) is still most sought after in India and has promising potential in management of Vishada [major depressive disorder (MDD)]. But, systematic research is lacking. In this study we evaluated of influence of ayurvedic treatment (Panchakarma and Ayushman-15) on psychopathology, heart rate variability (HRV) and endocrinal parameters in patients with major depression. 81 drug naive patients diagnosed as Vishada by ayurvedic physician and MDD according to DSM IV-TR were given ayurvedic Virechana module (therapeutic purgation) and were randomized into two groups. Patients in group A (n=41) received Ayushman-15A while group B (n=40) received Ayushman-15B for two months and Shirodhara (forehead-oil pouring therapy). Patients were assessed with Hamilton Depression Rating Scale (HDRS), Montgomery Asberg Depression Rating Scale (MADRS), Heart Rate Variability (HRV). Cortisol and adrenocorticotropic hormone (ACTH) were estimated at baseline and after ayurvedic therapy. HRV and endocrinal parameters were compared with age and gender matched healthy volunteers. HRV parameters showed significant sympathetic dominance in patients compared to healthy volunteers. Two months of ayurvedic treatment significantly decreased psychopathology, showed increase in vagal tone, decrease in sympathetic tone and reduced cortisol levels. However, there was no significant difference between groups receiving Ayushman A and B. This study provides evidence for antidepressant, cardiac (HRV) and beneficial neuroendocrine modulatory influence of Ayurveda therapy in patients of Vishada (MDD). Further studies are needed to confirm these findings. Greater insight into the neurobiology behind this therapy might provide valuable information about newer drug target. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Delayed heart rate recovery after exercise as a risk factor of incident type 2 diabetes mellitus after adjusting for glycometabolic parameters in men.

    PubMed

    Yu, Tae Yang; Jee, Jae Hwan; Bae, Ji Cheol; Hong, Won-Jung; Jin, Sang-Man; Kim, Jae Hyeon; Lee, Moon-Kyu

    2016-10-15

    Some studies have reported that delayed heart rate recovery (HRR) after exercise is associated with incident type 2 diabetes mellitus (T2DM). This study aimed to investigate the longitudinal association of delayed HRR following a graded exercise treadmill test (GTX) with the development of T2DM including glucose-associated parameters as an adjusting factor in healthy Korean men. Analyses including fasting plasma glucose, HOMA-IR, HOMA-β, and HbA1c as confounding factors and known confounders were performed. HRR was calculated as peak heart rate minus heart rate after a 1-min rest (HRR 1). Cox proportional hazards model was used to quantify the independent association between HRR and incident T2DM. During 9082 person-years of follow-up between 2006 and 2012, there were 180 (10.1%) incident cases of T2DM. After adjustment for age, BMI, systolic BP, diastolic BP, smoking status, peak heart rate, peak oxygen uptake, TG, LDL-C, HDL-C, fasting plasma glucose, HOMA-IR, HOMA-β, and HbA1c, the hazard ratios (HRs) [95% confidence interval (CI)] of incident T2DM comparing the second and third tertiles to the first tertile of HRR 1 were 0.867 (0.609-1.235) and 0.624 (0.426-0.915), respectively (p for trend=0.017). As a continuous variable, in the fully-adjusted model, the HR (95% CI) of incident T2DM associated with each 1 beat increase in HRR 1 was 0.980 (0.960-1.000) (p=0.048). This study demonstrated that delayed HRR after exercise predicts incident T2DM in men, even after adjusting for fasting glucose, HOMA-IR, HOMA-β, and HbA1c. However, only HRR 1 had clinical significance. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. Heart rate autonomic regulation system at rest and during paced breathing among patients with CRPS as compared to age-matched healthy controls.

    PubMed

    Bartur, Gadi; Vatine, Jean-Jacques; Raphaely-Beer, Noa; Peleg, Sara; Katz-Leurer, Michal

    2014-09-01

    The objective of this study is to assess the autonomic nerve heart rate regulation system at rest and its immediate response to paced breathing among patients with complex regional pain syndrome (CRPS) as compared with age-matched healthy controls. Quasiexperimental. Outpatient clinic. Ten patients with CRPS and 10 age- and sex-matched controls. Participants underwent Holter ECG (NorthEast Monitoring, Inc., Maynard, MA, USA) recording during rest and biofeedback-paced breathing session. Heart rate variability (HRV), time, and frequency measures were assessed. HRV and time domain values were significantly lower at rest among patients with CRPS as compared with controls. A significant association was noted between pain rank and HRV frequency measures at rest and during paced breathing; although both groups reduced breathing rate significantly during paced breathing, HRV time domain parameters increased only among the control group. The increased heart rate and decreased HRV at rest in patients with CRPS suggest a general autonomic imbalance. The inability of the patients to increase HRV time domain values during paced breathing may suggest that these patients have sustained stress response with minimal changeability in response to slow-paced breathing stimuli. Wiley Periodicals, Inc.

  16. Stress, Workload and Physiology Demand During Extravehicular Activity: A Pilot Study

    PubMed Central

    Rai, Balwant; Kaur, Jasdeep; Foing, Bernard H

    2012-01-01

    Background: Extravehicular activity (EVA), such as exercise performed under unique environmental conditions, is essential for supporting daily living in weightlessness and for further space exploration like long Mars mission. Aim: The study was planned stress, workload, and physiological demands of simulated Mars exploration. Materials and Methods: In this study, the six-person crew lived (24 hours) for 14 days during a short-term stay at the Mars Desert Research Station. The heart rates, salivary cortisol, workload, peak oxygen uptake or maximal aerobic capacity of the crew are measured before, during and after an EVA. Results: Data for heart rate showed the same trend as peak oxygen uptake or maximal aerobic capacity, with a maximal increase to 85% of peak. The rating of subscale showed a significant increase in EVA as compared to run. Salivary cortisol levels and heart rates were increased in both groups, although significant increased of cortisol levels and heart rates more in EVA as compared to hill running crew members. Conclusion: Further study is required on large scale taken into account of limitations of this study and including other physiological and psychological parameters in Mars analog environment. PMID:22754877

  17. Multi-objective control of nonlinear boiler-turbine dynamics with actuator magnitude and rate constraints.

    PubMed

    Chen, Pang-Chia

    2013-01-01

    This paper investigates multi-objective controller design approaches for nonlinear boiler-turbine dynamics subject to actuator magnitude and rate constraints. System nonlinearity is handled by a suitable linear parameter varying system representation with drum pressure as the system varying parameter. Variation of the drum pressure is represented by suitable norm-bounded uncertainty and affine dependence on system matrices. Based on linear matrix inequality algorithms, the magnitude and rate constraints on the actuator and the deviations of fluid density and water level are formulated while the tracking abilities on the drum pressure and power output are optimized. Variation ranges of drum pressure and magnitude tracking commands are used as controller design parameters, determined according to the boiler-turbine's operation range. Copyright © 2012 ISA. Published by Elsevier Ltd. All rights reserved.

  18. Effects of electromagnetic radiation from 3G mobile phone on heart rate, blood pressure and ECG parameters in rats.

    PubMed

    Colak, Cengiz; Parlakpinar, Hakan; Ermis, Necip; Tagluk, Mehmet Emin; Colak, Cemil; Sarihan, Ediz; Dilek, Omer Faruk; Turan, Bahadir; Bakir, Sevtap; Acet, Ahmet

    2012-08-01

    Effects of electromagnetic energy radiated from mobile phones (MPs) on heart is one of the research interests. The current study was designed to investigate the effects of electromagnetic radiation (EMR) from third-generation (3G) MP on the heart rate (HR), blood pressure (BP) and ECG parameters and also to investigate whether exogenous melatonin can exert any protective effect on these parameters. In this study 36 rats were randomized and evenly categorized into 4 groups: group 1 (3G-EMR exposed); group 2 (3G-EMR exposed + melatonin); group 3 (control) and group 4 (control + melatonin). The rats in groups 1 and 2 were exposed to 3G-specific MP's EMR for 20 days (40 min/day; 20 min active (speech position) and 20 min passive (listening position)). Group 2 was also administered with melatonin for 20 days (5 mg/kg daily during the experimental period). ECG signals were recorded from cannulated carotid artery both before and after the experiment, and BP and HR were calculated on 1st, 3rd and 5th min of recordings. ECG signals were processed and statistically evaluated. In our experience, the obtained results did not show significant differences in the BP, HR and ECG parameters among the groups both before and after the experiment. Melatonin, also, did not exhibit any additional effects, neither beneficial nor hazardous, on the heart hemodynamics of rats. Therefore, the strategy (noncontact) of using a 3G MP could be the reason for ineffectiveness; and use of 3G MP, in this perspective, seems to be safer compared to the ones used in close contact with the head. However, further study is needed for standardization of such an assumption.

  19. First third filling parameters of left ventricle assessed from gated equilibrium studies in patients with various heart diseases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adatepe, M.H.; Nichols, K.; Powell, O.M.

    1984-01-01

    The authors determined the first third filling fraction (1/3 FF), the maximum filling rate (1/3 FR) and the mean filling rate (1/3 MFR) for the first third diastolic filling period of the left ventricle in patients with coronary artery disease (CAD), valvular heart disease (VHD), pericardial effusion (PE), cardiomyopathies (CM), chronic obstructive lung disease (COPD) and in 5 normals-all from resting gated equilibrium studies. Parameters are calculated from the third order Fourier fit to the LV volume curve and its derivative. 1/3 FF% = 1/3 diastolic count - end systolic count / 1/3 diastolic count x 100. Patients with CADmore » are divided into two groups: Group I with normal ejection fraction (EF) and wall motion (WM); Group II with abnormal EF and WM. Results are shown in the table. Abnormal filling parameters are found not only in CAD but in VHD, PE and CM. The authors conclude that the first third LV filling parameters are sensitive but non-specific indicators of filling abnormalities caused by diverse etiologic factors. Abnormal first third filling parameters may occur in the presence of a normal resting EF and WM in CAD.« less

  20. Comparison of neostigmine and sugammadex for hemodynamic parameters in cardiac patients undergoing noncardiac surgery.

    PubMed

    Kizilay, Deniz; Dal, Didem; Saracoglu, Kemal T; Eti, Zeynep; Gogus, Fevzi Y

    2016-02-01

    The aim of this study is to compare the hemodynamic effects of neostigmine-atropine combination and sugammadex in patients with cardiac problems undergoing noncardiac surgery. Prospective randomized study. In the operating room. Ninety patients with a class 2 or 3 cardiovascular disease according to the New York Heart Association classification and aged between 18 and 75 years undergoing noncardiac surgery were randomized. Group N (n = 45) received 0.03 mg/kg IV neostigmine when T2 appeared as measured with a nerve muscle stimulator. When heart rate was 5 beats/min (±10 beats/min) lower than the heart rate before administration of the medication, 0.5 mg IV atropine sulfate was given. Group S (n = 45) received 3 mg/kg IV sugammadex when T2 appeared as measured with a nerve muscle stimulator. Heart rate, mean systolic and diastolic blood pressures, and electrocardiographic alterations including the QTc (QT Fredericia and QT Bazett) were recorded. There were no significant differences between and within the groups in terms of QTc values. Sugammadex group had a significant decrease on heart rate 1 minute after the medication when compared to the measurement before the medication (P < .05). Heart rate and systolic blood pressure increased in neostigmine group 3 minutes after the medication and during postoperative measurements (P < .05). Sugammadex group had lower systolic, diastolic, and mean blood pressures and heart rate when compared to neostigmine group (P < .05). We suggest that sugammadex might be preferred as it provides more hemodynamic stability compared to neostigmine-atropine combination to reverse rocuronium-induced neuromuscular blockage in cardiac patients undergoing noncardiac surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Exercise effect with the wheelchair aerobic fitness trainer on conditioning and metabolic function in disabled persons: a pilot study.

    PubMed

    Midha, M; Schmitt, J K; Sclater, M

    1999-03-01

    To determine the effect of exercise with the wheelchair aerobic fitness trainer (WAFT) on anthropometric indices, conditioning, and endocrine and metabolic parameters in persons with lower extremity disability. Exercise sessions with the WAFT lasted 20 to 30 minutes for two to three sessions. Tertiary-care Veterans Administration medical center. Twelve subjects (3 with quadriplegia, 7 with paraplegia, 1 with cerebrovascular accident, 1 with bilateral above-knee amputation). Anthropometric indices (heart rate, blood pressure, weight, oxygen utilization, body mass index, upper arm and abdominal circumference, arm power) and endocrine and metabolic parameters (fasting serum glucose, lipids, and thyroid function) were determined before and after 10 weeks of exercise with the WAFT. All patients noted improved feelings of well-being after training. Mean resting heart rate, upper arm fat area, and fasting serum cholesterol level decreased significantly. Peak oxygen consumption, midarm circumference, and free thyroxine index increased significantly with training. WAFT improves quality of life, conditioning, and endocrine-metabolic parameters in disabled persons.

  2. Heart rate variability and heart rate turbulence in patients with polycystic ovary syndrome.

    PubMed

    Özkeçeci, Gülay; Ünlü, Bekir Serdar; Dursun, Hüseyin; Akçi, Önder; Köken, Gülengül; Onrat, Ersel; Avşar, Alaettin

    2016-05-01

    Cardiac autonomic dysfunction may develop in patients with polycystic ovary syndrome (PCOS). Heart rate variability (HRV) and heart rate turbulence (HRT) are used in assessing cardiac autonomic functions. The goal of this study was to compare the cardiac autonomic functions in patients with PCOS and healthy controls. To our knowledge, this is the first study evaluating cardiac autonomic functions in patients with PCOS with respect to both HRV and HRT. Twenty-three patients with PCOS (mean age 22.8±3.9 years) and 25 healthy female volunteers who were matched for age and body mass index (BMI) (mean age 23.5±6.2 years) were enrolled in this as case-control study. Twenty-four hour ambulatory electrocardiogram recordings of all participants were taken using Pathfinder software. The time domain parameters of HRV and HRT, including turbulence onset (TO) and turbulence slope, were calculated. Diagnosis of PCOS was made with physical and laboratory findings of hirsutism or biochemical hyperandrogenism and chronic anovulation. Diabetes mellitus, other hormon disorders or hormon therapy, pregnancy, atrial fibrilation, obesite, chronic diseases, disorders of the autonomic nervous system, a history of drug use affecting the autonomic nervous system were excluded. There were no significant differences in HRV and HRT parameters between the two groups. Cardiovascular risk factors, such as BMI, blood pressure, fasting blood glucose, and lipid parameters, were also similar. Triangular index measure of HRV was negatively correlated with high density lipoprotein cholesterol levels (r=-0.47, p<0.05), while age and BMI were significantly correlated with TO (r=0.31 and 0.47, respectively; p<0.05 for all). Cardiac autonomic functions were not found to be altered in patients with PCOS in comparison with healthy controls. These results may be explained with the absence of concomitant cardiovascular risk factors with the patients being in the early stage of the disease.

  3. Possible influence of solar extreme events and related geomagnetic disturbances on human cardio-vascular state: Results of collaborative Bulgarian-Azerbaijani studies

    NASA Astrophysics Data System (ADS)

    Dimitrova, S.; Mustafa, F. R.; Stoilova, I.; Babayev, E. S.; Kazimov, E. A.

    2009-02-01

    This collaborative study is based on the analysis and comparison of results of coordinated experimental investigations conducted in Bulgaria and Azerbaijan for revealing a possible influence of solar activity changes and related geomagnetic activity variations on the human cardio-vascular state. Arterial blood pressure and heart rate of 86 healthy volunteers were measured on working days during a period of comparatively high solar and geomagnetic activity (2799 measurements in autumn 2001 and spring 2002) in Sofia. Daily experimental investigations of parameters of cardio-vascular health state were performed in Azerbaijan with a permanent group of examined persons. Heart rate and electrocardiograms were digitally registered (in total 1532 records) for seven functionally healthy persons on working days and Saturdays, in the Laboratory of Heliobiology at the Medical Center INAM in Baku, from 15.07.2006 to 13.11.2007. Obtained digital recordings were subjected to medical, statistical and spectral analyses. Special attention was paid to effects of solar extreme events, particularly those of November 2001 and December 2006. The statistical method of the analysis of variance (ANOVA) and post hoc analysis were applied to check the significance of the influence of geomagnetic activity on the cardio-vascular parameters under consideration. Results revealed statistically significant increments for the mean systolic and diastolic blood pressure values of the group with geomagnetic activity increase. Arterial blood pressure values started increasing two days prior to geomagnetic storms and kept their high values up to two days after the storms. Heart rate reaction was ambiguous and not significant for healthy persons examined (for both groups) under conditions with geomagnetic activity changes. It is concluded that heart rate for healthy persons at middle latitudes can be considered as a more stable physiological parameter which is not so sensitive to environmental changes while the dynamics of arterial blood pressure reveals a compensatory reaction of the human organism for adaptation.

  4. Scale-free dynamics of the synchronization between sleep EEG power bands and the high frequency component of heart rate variability in normal men and patients with sleep apnea-hypopnea syndrome.

    PubMed

    Dumont, Martine; Jurysta, Fabrice; Lanquart, Jean-Pol; Noseda, André; van de Borne, Philippe; Linkowski, Paul

    2007-12-01

    To investigate the dynamics of the synchronization between heart rate variability and sleep electroencephalogram power spectra and the effect of sleep apnea-hypopnea syndrome. Heart rate and sleep electroencephalogram signals were recorded in controls and patients with sleep apnea-hypopnea syndrome that were matched for age, gender, sleep parameters, and blood pressure. Spectral analysis was applied to electrocardiogram and electroencephalogram sleep recordings to obtain power values every 20s. Synchronization likelihood was computed between time series of the normalized high frequency spectral component of RR-intervals and all electroencephalographic frequency bands. Detrended fluctuation analysis was applied to the synchronizations in order to qualify their dynamic behaviors. For all sleep bands, the fluctuations of the synchronization between sleep EEG and heart activity appear scale free and the scaling exponent is close to one as for 1/f noise. We could not detect any effect due to sleep apnea-hypopnea syndrome. The synchronizations between the high frequency component of heart rate variability and all sleep power bands exhibited robust fluctuations characterized by self-similar temporal behavior of 1/f noise type. No effects of sleep apnea-hypopnea syndrome were observed in these synchronizations. Sleep apnea-hypopnea syndrome does not affect the interdependence between the high frequency component of heart rate variability and all sleep power bands as measured by synchronization likelihood.

  5. Diminution of Heart Rate Variability in Bipolar Depression

    PubMed Central

    Hage, Brandon; Britton, Briana; Daniels, David; Heilman, Keri; Porges, Stephen W.; Halaris, Angelos

    2017-01-01

    Autonomic nervous system (ANS) dysregulation in depression is associated with symptoms associated with the ANS. The beat-to-beat pattern of heart rate defined as heart rate variability (HRV) provides a noninvasive portal to ANS function and has been proposed to represent a means of quantifying resting vagal tone. We quantified HRV in bipolar depressed (BDD) patients as a measure of ANS dysregulation seeking to establish HRV as a potential diagnostic and prognostic biomarker for treatment outcome. Forty-seven BDD patients were enrolled. They were randomized to receive either escitalopram–celecoxib or escitalopram-placebo over 8 weeks in a double-blind study design. Thirty-five patients completed the HRV studies. Thirty-six healthy subjects served as controls. HRV was assessed at pretreatment and end of study and compared with that of controls. HRV was quantified and corrected for artifacts using an algorithm that incorporates time and frequency domains to address non-stationarity of the beat-to-beat heart rate pattern. Baseline high frequency-HRV (i.e., respiratory sinus arrhythmia) was lower in BDD patients than controls, although the difference did not reach significance. Baseline low-frequency HRV was significantly lower in BDD patients (ln4.20) than controls (ln = 5.50) (p < 0.01). Baseline heart period was significantly shorter (i.e., faster heart rate) in BDD patients than controls. No significant change in HRV parameters were detected over the course of the study with either treatment. These findings suggest that components of HRV may be diminished in BDD patients. PMID:29270399

  6. Exo-organoplasty interventions: A brief review of past, present and future directions for advance heart failure management.

    PubMed

    Nawaz, Waqas; Khan, Farhan Ullah; Khan, Muhammad Zahid; Gang, Wang; Yang, Mengqi; Liao, Xiaoqian; Zhang, Li; Ihsan, Awais Ullah; Khan, Amjad; Han, Lei; Zhou, Xiaohui

    2017-04-01

    Heart failure (HF) is a debilitating disease in which abnormal function of the heart leads to imbalance of blood demand to tissues and organs. The pathogenesis of HF is very complex and various factors can contribute including myocardial infarction, ischemia, hypertension and genetic cardiomyopathies. HF is the leading cause of death and its prevalence is expected to increase in parallel with the population age. Different kind of therapeutic approaches including lifestyle modification, medication and pacemakers are used for HF patients in NYHA I-III functional class. However, for advance stage HF patient's (NYHA IV), ventricle assist devices are clinically use and stem cells are under active investigation. Most of these therapies leads to modest symptoms relief and have no significant role in long-term survival rate. Currently there is no effective treatment for advance HF except heart transplantation, which is still remain clinically insignificant because of donor pool limitation. As HF is a result of multiple etiologies therefore multi-functional therapeutic platform is needed. Exo-organoplasty interventions are studied from almost one century. The major goals of these interventions are to treat various kind of heart disease from outside the heart muscle without having direct contact with blood. Various kind of interventions (devices and techniques) are developed in this arena with the passage of time. The purpose of this review is to describe the theory behind intervention devices, the devices themselves, their clinical results, advantages and limitations. Furthermore, to present a future multi-functional therapeutic platform (ASD) for advance stage HF management. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  7. Iris features-based heart disease diagnosis by computer vision

    NASA Astrophysics Data System (ADS)

    Nguchu, Benedictor A.; Li, Li

    2017-07-01

    The study takes advantage of several new breakthroughs in computer vision technology to develop a new mid-irisbiomedical platform that processes iris image for early detection of heart-disease. Guaranteeing early detection of heart disease provides a possibility of having non-surgical treatment as suggested by biomedical researchers and associated institutions. However, our observation discovered that, a clinical practicable solution which could be both sensible and specific for early detection is still lacking. Due to this, the rate of majority vulnerable to death is highly increasing. The delayed diagnostic procedures, inefficiency, and complications of available methods are the other reasons for this catastrophe. Therefore, this research proposes the novel IFB (Iris Features Based) method for diagnosis of premature, and early stage heart disease. The method incorporates computer vision and iridology to obtain a robust, non-contact, nonradioactive, and cost-effective diagnostic tool. The method analyzes abnormal inherent weakness in tissues, change in color and patterns, of a specific region of iris that responds to impulses of heart organ as per Bernard Jensen-iris Chart. The changes in iris infer the presence of degenerative abnormalities in heart organ. These changes are precisely detected and analyzed by IFB method that includes, tensor-based-gradient(TBG), multi orientations gabor filters(GF), textural oriented features(TOF), and speed-up robust features(SURF). Kernel and Multi class oriented support vector machines classifiers are used for classifying normal and pathological iris features. Experimental results demonstrated that the proposed method, not only has better diagnostic performance, but also provides an insight for early detection of other diseases.

  8. Heart rate variability in workers chronically exposed to lead.

    PubMed

    Gajek, Jacek; Zyśko, Dorota; Chlebda, Ewa

    2004-07-01

    Lead is a strong neurotoxin. The effects of lead on the activity of the autonomic nervous system, assessed by the use of heart rate variability (HRV) analysis, have not yet been established. To assess the effects of occupational chronic lead exposure on the autonomic nervous system activity. The study group consisted of 22 copper foundry workers (mean age 41.8+/-8.7 years) who had elevated parameters of lead overload and were admitted to the hospital for chelate therapy. The control group consisted of 13 age-matched healthy males. Lead concentration was measured with the use of atomic absorption spectrophotometry, and concentration of free protoporphyrins in erythrocytes (FEP) using a fluorometric method. Each patient underwent 24-hour ambulatory ECG monitoring, and standard short-term as well as long-term HRV parameters were obtained. There were no significant differences between patients and controls in HRV parameters. In the control group, HRV parameters correlated with age. In patients, a significant negative correlation between lead concentration and some short-term HRV parameters calculated during the night was found: SDNN (r=-0.48, p<0.05), TP (r=-0.48, p<0.01) and LF (r=-0.48, p<0.01). In patients, a negative correlation between lead concentration and HFnight/HFday index was found (r=-0.47 p<0.01), whereas in controls this correlation was positive (r=0.66 p<0.05). Overall HRV indices are similar in subjects exposed to lead and in healthy controls. A decrease in the physiological elevation of HF values during the night, together with an increase in lead blood concentration and lack of relationship between age and HRV parameters in workers chronically exposed to lead may suggest disturbances of the autonomic system. In subjects not exposed to lead a decrease in heart rate with an increase in FEP concentration was observed.

  9. Heart rate and blood pressure variations after transvascular patent ductus arteriosus occlusion in dogs.

    PubMed

    De Monte, Valentina; Staffieri, Francesco; Caivano, Domenico; Nannarone, Sara; Birettoni, Francesco; Porciello, Francesco; Di Meo, Antonio; Bufalari, Antonello

    2017-08-01

    The objective of the study was to retrospectively analyse the cardiovascular effects that occurs following the transvascular occlusion of patent ductus arteriosus in dogs. Sixteen anaesthesia records were included. Variables were recorded at the time of placing the arterial introducer, occlusion of the ductus, and from 5 to 60min thereafter, including, among the other, heart rate, systolic, diastolic and mean arterial blood pressure. The maximal percentage variation of the aforementioned physiological parameters within 60min of occlusion, compared with the values recorded at the introducer placing, was calculated. The time at which maximal variation occurred was also computed. Correlations between maximal percentage variation of physiological parameters and the diameter of the ductus and systolic and diastolic flow velocity through it were evaluated with linear regression analysis. Heart rate decreased after occlusion of the ductus with a mean maximal percentage variation of 41.0±14.8% after 21.2±13.7min. Mean and diastolic arterial blood pressure increased after occlusion with a mean maximal percentage variation of 30.6±18.1 and 55.4±27.1% after 19.6±12.1 and 15.7±10.8min, respectively. Mean arterial blood pressure variation had a significant and moderate inverse correlation with diastolic and systolic flow velocity through the ductus. Transvascular patent ductus arteriosus occlusion in anaesthetised dogs causes a significant reduction in heart rate and an increase in diastolic and mean blood arterial pressure within 20min of closure of the ductus. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Implantable cardiac resynchronization therapy devices to monitor heart failure clinical status.

    PubMed

    Fung, Jeffrey Wing-Hong; Yu, Cheuk-Man

    2007-03-01

    Cardiac resynchronization therapy is a standard therapy for selected patients with heart failure. With advances in technology and storage capacity, the device acts as a convenient platform to provide valuable information about heart failure status in these high-risk patients. Unlike other modalities of investigation which may only allow one-off evaluation, heart failure status can be monitored by device diagnostics including heart rate variability, activity status, and intrathoracic impedance in a continuous basis. These parameters do not just provide long-term prognostic information but also may be useful to predict upcoming heart failure exacerbation. Prompt and early intervention may abort decompensation, prevent hospitalization, improve quality of life, and reduce health care cost. Moreover, this information may be applied to titrate the dosage of medication and monitor response to heart failure treatment. This review will focus on the prognostic and predictive values of heart failure status monitoring provided by these devices.

  11. A wireless modular multi-modal multi-node patch platform for robust biosignal monitoring.

    PubMed

    Pantelopoulos, Alexandros; Saldivar, Enrique; Roham, Masoud

    2011-01-01

    In this paper a wireless modular, multi-modal, multi-node patch platform is described. The platform comprises low-cost semi-disposable patch design aiming at unobtrusive ambulatory monitoring of multiple physiological parameters. Owing to its modular design it can be interfaced with various low-power RF communication and data storage technologies, while the data fusion of multi-modal and multi-node features facilitates measurement of several biosignals from multiple on-body locations for robust feature extraction. Preliminary results of the patch platform are presented which illustrate the capability to extract respiration rate from three different independent metrics, which combined together can give a more robust estimate of the actual respiratory rate.

  12. Cyclic bouts of extreme bradycardia counteract the high metabolism of frugivorous bats

    PubMed Central

    Wikelski, Martin; Voigt, Christian C; Ter Maat, Andries; Pollock, Henry S; Burness, Gary; Desantis, Lanna M; Dechmann, Dina KN

    2017-01-01

    Active flight requires the ability to efficiently fuel bursts of costly locomotion while maximizing energy conservation during non-flying times. We took a multi-faceted approach to estimate how fruit-eating bats (Uroderma bilobatum) manage a high-energy lifestyle fueled primarily by fig juice. Miniaturized heart rate telemetry shows that they use a novel, cyclic, bradycardic state that reduces daily energetic expenditure by 10% and counteracts heart rates as high as 900 bpm during flight. Uroderma bilobatum support flight with some of the fastest metabolic incorporation rates and dynamic circulating cortisol in vertebrates. These bats will exchange fat reserves within 24 hr, meaning that they must survive on the food of the day and are at daily risk of starvation. Energetic flexibly in U. bilobatum highlights the fundamental role of ecological pressures on integrative energetic networks and the still poorly understood energetic strategies of animals in the tropics. PMID:28923167

  13. Optogenetic pacing in Drosophila models (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Wu, Penghe; Li, Airong; Men, Jing; Tans, Rudolph E.; Zhou, Chao

    2017-02-01

    The Drosophila melanogaster shares many similarities with vertebrates in heart development. Comparison of heart structural and functional characteristic between male and female Drosophila melanogaster at different developmental stages is helpful to understand heart morphogenesis and function for different genders. And also, it opens up the possibility to uncover the role of sex-related genes in heart development. In this longitudinal study, we cultured and tracked dozens of individually labeled flies throughout their lifecycle. The heart characteristic was measured at different developmental stages during culturing. The gender of each individual fly was determined by adult stage so that the collected data of early stages could be classified to male or female group. We adapted a high-speed optical coherence microscopy (OCM) system with axial and transverse resolution of 2um and 4um, respectively, to perform non-invasive M-mode imaging at a frame rate of 132Hz in Drosophila heart at third instar larva, early pupa and adult stage. Based on those GPU processed M-mode OCM images, we segmented the fly heart region and then quantified the cardiac structural and functional parameters such as heart rate, heart chamber size and so on. Despite large variances of wild type Drosophila in terms of some cardiac characteristic, our results suggest that the heart rate is lower for male flies than for female flies, especially at third instar larva stage. The end diastolic area (EDA) and end systolic area (ESA) of the heart are both slightly larger in female flies than in male flies at larva and adult stage. In summary, we showed gender differences of wild type drosophila in heart functional and structural characteristic.

  14. [Non-destructive detection research for hollow heart of potato based on semi-transmission hyperspectral imaging and SVM].

    PubMed

    Huang, Tao; Li, Xiao-yu; Xu, Meng-ling; Jin, Rui; Ku, Jing; Xu, Sen-miao; Wu, Zhen-zhong

    2015-01-01

    The quality of potato is directly related to their edible value and industrial value. Hollow heart of potato, as a physiological disease occurred inside the tuber, is difficult to be detected. This paper put forward a non-destructive detection method by using semi-transmission hyperspectral imaging with support vector machine (SVM) to detect hollow heart of potato. Compared to reflection and transmission hyperspectral image, semi-transmission hyperspectral image can get clearer image which contains the internal quality information of agricultural products. In this study, 224 potato samples (149 normal samples and 75 hollow samples) were selected as the research object, and semi-transmission hyperspectral image acquisition system was constructed to acquire the hyperspectral images (390-1 040 nn) of the potato samples, and then the average spectrum of region of interest were extracted for spectral characteristics analysis. Normalize was used to preprocess the original spectrum, and prediction model were developed based on SVM using all wave bands, the accurate recognition rate of test set is only 87. 5%. In order to simplify the model competitive.adaptive reweighed sampling algorithm (CARS) and successive projection algorithm (SPA) were utilized to select important variables from the all 520 spectral variables and 8 variables were selected (454, 601, 639, 664, 748, 827, 874 and 936 nm). 94. 64% of the accurate recognition rate of test set was obtained by using the 8 variables to develop SVM model. Parameter optimization algorithms, including artificial fish swarm algorithm (AFSA), genetic algorithm (GA) and grid search algorithm, were used to optimize the SVM model parameters: penalty parameter c and kernel parameter g. After comparative analysis, AFSA, a new bionic optimization algorithm based on the foraging behavior of fish swarm, was proved to get the optimal model parameter (c=10. 659 1, g=0. 349 7), and the recognition accuracy of 10% were obtained for the AFSA-SVM model. The results indicate that combining the semi-transmission hyperspectral imaging technology with CARS-SPA and AFSA-SVM can accurately detect hollow heart of potato, and also provide technical support for rapid non-destructive detecting of hollow heart of potato.

  15. Physiological Factors Analysis in Unpressurized Aircraft Cabins

    NASA Astrophysics Data System (ADS)

    Patrao, Luis; Zorro, Sara; Silva, Jorge

    2016-11-01

    Amateur and sports flight is an activity with growing numbers worldwide. However, the main cause of flight incidents and accidents is increasingly pilot error, for a number of reasons. Fatigue, sleep issues and hypoxia, among many others, are some that can be avoided, or, at least, mitigated. This article describes the analysis of psychological and physiological parameters during flight in unpressurized aircraft cabins. It relates cerebral oximetry and heart rate with altitude, as well as with flight phase. The study of those parameters might give clues on which variations represent a warning sign to the pilot, thus preventing incidents and accidents due to human factors. Results show that both cerebral oximetry and heart rate change along the flight and altitude in the alert pilot. The impaired pilot might not reveal these variations and, if this is detected, he can be warned in time.

  16. A Prospective Comparison Study of Heart Rate Variability During Menses in Young Women With Dysmenorrhea.

    PubMed

    Wang, Yu-Jen; Wang, Yi-Zen; Yeh, Mei-Ling

    2016-07-01

    Numerous studies have demonstrated autonomic abnormalities in various pain conditions. However, few have investigated heart rate variability (HRV) in young women with primary dysmenorrhea, and the conclusions have been inconsistent. More evidence is required to confirm the reported trend for consistent fluctuation of HRV parameters in dysmenorrhea. The study's aim was to determine whether significant differences exist between young women with and without dysmenorrhea for heart rate (HR), blood pressure (BP), and HRV parameters during menses. A prospective comparison design with repeated measures was used. Sixty-six women aged 18-25 with dysmenorrhea and 54 eumenorrheic women were recruited from a university in northern Taiwan. High-frequency and low-frequency HRV parameters (HF and LF), LF/HF ratio, BP, and HR were measured daily between 8 p.m. and 10 p.m. from Day 1 to Day 6 during menses. The generalized estimating equation was used to analyze the effects of group, time, and Group × Time interaction on these variables. HF values were significantly lower in the dysmenorrhea than in the eumenorrhea group, but there were no differences in BP, HR, LF, or LF/HF ratio. Reduced HF values reflect reduced parasympathetic activity and autonomic instability in young women with dysmenorrhea. Future longitudinal studies are warranted to examine autonomic regulation in menstrual pain of varying intensities associated with dysmenorrhea-related symptoms and to clarify the causal relationship between dysmenorrhea and HRV fluctuations. © The Author(s) 2016.

  17. Linear Phase Sharp Transition BPF to Detect Noninvasive Maternal and Fetal Heart Rate.

    PubMed

    Marchon, Niyan; Naik, Gourish; Pai, K R

    2018-01-01

    Fetal heart rate (FHR) detection can be monitored using either direct fetal scalp electrode recording (invasive) or by indirect noninvasive technique. Weeks before delivery, the invasive method poses a risk factor to the fetus, while the latter provides accurate fetal ECG (FECG) information which can help diagnose fetal's well-being. Our technique employs variable order linear phase sharp transition (LPST) FIR band-pass filter which shows improved stopband attenuation at higher filter orders. The fetal frequency fiduciary edges form the band edges of the filter characterized by varying amounts of overlap of maternal ECG (MECG) spectrum. The one with the minimum maternal spectrum overlap was found to be optimum with no power line interference and maximum fetal heart beats being detected. The improved filtering is reflected in the enhancement of the performance of the fetal QRS detector (FQRS). The improvement has also occurred in fetal heart rate obtained using our algorithm which is in close agreement with the true reference (i.e., invasive fetal scalp ECG). The performance parameters of the FQRS detector such as sensitivity (Se), positive predictive value (PPV), and accuracy (F 1 ) were found to improve even for lower filter order. The same technique was extended to evaluate maternal QRS detector (MQRS) and found to yield satisfactory maternal heart rate (MHR) results.

  18. Application of Universal Thermal Climate Index (UTCI) for assessment of occupational heat stress in open-pit mines.

    PubMed

    Nassiri, Parvin; Monazzam, Mohammad Reza; Golbabaei, Farideh; Dehghan, Somayeh Farhang; Rafieepour, Athena; Mortezapour, Ali Reza; Asghari, Mehdi

    2017-10-07

    The purpose of this article is to examine the applicability of Universal Thermal Climate Index (UTCI) index as an innovative index for evaluating of occupational heat stress in outdoor environments. 175 workers of 12 open-pit mines in Tehran, Iran were selected for this research study. First, the environmental variables such as air temperature, wet-bulb temperature, globe temperature, relative humidity and air flow rate were measured; then UTCI, wet-bulb globe temperature (WBGT) and heat stress index (HSI) indices were calculated. Simultaneously, physiological parameters including heart rate, oral temperature, tympanic temperature and skin temperature of workers were measured. UTCI and WBGT are positively significantly correlated with all environmental parameters (p<0.03), except for air velocity (r<-0.39; p>0.05). Moreover, a strong significant relationship was found between UTCI and WBGT (r=0.95; p<0.001). The significant positive correlations exist between physiological parameters including oral temperature, tympanic and skin temperatures and heart rate and both the UTCI and WBGT indices (p<0.029). The highest correlation coefficient has been found between the UTCI and physiological parameters. Due to the low humidity and air velocity (~<1 m/s) in understudied mines, UTCI index appears to be appropriate to assess the occupational heat stress in these outdoor workplaces.

  19. Sensitivity analysis and comparison of two methods of using heart rate to represent energy expenditure during walking.

    PubMed

    Karimi, Mohammad Taghi

    2015-01-01

    Heart rate is an accurate and easy to use method to represent the energy expenditure during walking, based on physiological cost index (PCI). However, in some conditions the heart rate during walking does not reach to a steady state. Therefore, it is not possible to determine the energy expenditure by use of the PCI index. The total heart beat index (THBI) is a new method to solve the aforementioned problem. The aim of this research project was to find the sensitivity of both the physiological cost index (PCI) and total heart beat index (THBI). Fifteen normal subjects and ten patients with flatfoot disorder and two subjects with spinal cord injury were recruited in this research project. The PCI and THBI indexes were determined by use of heart beats with respect to walking speed and total distance walked, respectively. The sensitivity of PCI was more than that of THBI index in the three groups of subjects. Although the PCI and THBI indexes are easy to use and reliable parameters to represent the energy expenditure during walking, their sensitivity is not high to detect the influence of some orthotic interventions, such as use of insoles or using shoes on energy expenditure during walking.

  20. Estimation of Circadian Body Temperature Rhythm Based on Heart Rate in Healthy, Ambulatory Subjects.

    PubMed

    Sim, Soo Young; Joo, Kwang Min; Kim, Han Byul; Jang, Seungjin; Kim, Beomoh; Hong, Seungbum; Kim, Sungwan; Park, Kwang Suk

    2017-03-01

    Core body temperature is a reliable marker for circadian rhythm. As characteristics of the circadian body temperature rhythm change during diverse health problems, such as sleep disorder and depression, body temperature monitoring is often used in clinical diagnosis and treatment. However, the use of current thermometers in circadian rhythm monitoring is impractical in daily life. As heart rate is a physiological signal relevant to thermoregulation, we investigated the feasibility of heart rate monitoring in estimating circadian body temperature rhythm. Various heart rate parameters and core body temperature were simultaneously acquired in 21 healthy, ambulatory subjects during their routine life. The performance of regression analysis and the extended Kalman filter on daily body temperature and circadian indicator (mesor, amplitude, and acrophase) estimation were evaluated. For daily body temperature estimation, mean R-R interval (RRI), mean heart rate (MHR), or normalized MHR provided a mean root mean square error of approximately 0.40 °C in both techniques. The mesor estimation regression analysis showed better performance than the extended Kalman filter. However, the extended Kalman filter, combined with RRI or MHR, provided better accuracy in terms of amplitude and acrophase estimation. We suggest that this noninvasive and convenient method for estimating the circadian body temperature rhythm could reduce discomfort during body temperature monitoring in daily life. This, in turn, could facilitate more clinical studies based on circadian body temperature rhythm.

  1. Dark chocolate and blood pressure: a novel study from Jordan.

    PubMed

    Al-Safi, Saafan A; Ayoub, Nehad M; Al-Doghim, Imad; Aboul-Enein, Faisal H

    2011-11-01

    The goal of this study was to assess the effect of dark chocolate intake on cardiovascular parameters like blood pressure and heart rate values in a normotensive population. This is a randomized cross-sectional study involving a total of 14,310 adults that were selected from various regions of Jordan. Well-trained pharmacy students interviewed participants in the outpatient settings. Participants reported their weekly intake of dark chocolate that has been further classified into mild (1-2 bars/week), moderate (3-4 bars/week), and high intake ( > 4 bars/week). For each participant, the systolic blood pressure (SBP), diastolic blood pressure (DBP), and heart rate were measured three times with (10-15) minute intervals in the sitting position and the resting state. The arterial blood pressure (ABP) was calculated from the measured SBP and DBP values. All measured blood pressure values were significantly decreased for participants who reported higher dark chocolate consumption. Our results showed that heart rate values were not affected by variable intake of dark chocolate. In addition, increasing dark chocolate intake was associated with a significant decrease of blood pressure values in participants irrespective of the family history of hypertension or the age of the individual. However, heart rate values were unaffected. Higher intake of dark chocolate can be associated with lower values of blood pressure, while its effect on heart rate values was not consistent.

  2. Panic and comorbid depression and their associations with stress reactivity, interoceptive awareness and interoceptive accuracy of various bioparameters.

    PubMed

    Limmer, Jan; Kornhuber, Johannes; Martin, Alexandra

    2015-10-01

    While current theories on perception of interoceptive signals suggest impaired interoceptive processing in psychiatric disorders such as panic disorder or depression, heart-rate (HR) interoceptive accuracy (IAc) of panic patients under resting conditions is superior to that of healthy controls. Thus, in this study, we chose to assess further physiological parameters and comorbid depression in order to get information on how these potentially conflicting findings are linked together. We used a quasi-experimental laboratory design which included multi-parametric physiological data collection of 40 panic subjects and 53 matched no-panic controls, as well as experimental induction of stress and relaxation over a time-course. Stress reactivity, interoceptive awareness (IAw; from the Body Perception Questionnaire (BPQ)) and IAc (as correlation between self-estimation and physiological data) were major outcome variables. Self-estimation of bioparametrical change was measured via numeric rating scales. Panic subjects had stronger HR-reaction and more accurate HR-interoception. Concurrently, though, their IAc of skin conductance level, pulse amplitude and breathing amplitude was significantly lower than that of the control group. Interestingly, comorbid depression was found to be associated with increased IAw but attenuated IAc. Demand characteristics and a categorical approach to panic confine the results. The potentially conflicting findings coalesce, as panic was associated with an increase of the ability to perceive the fear-related parameter and a simultaneous decrease of the ability to perceive other parameters. The superordinate integration of afferent signals might be impaired. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  3. Transthoracic Cardiac Ultrasonic Stimulation Induces a Negative Chronotropic Effect

    PubMed Central

    Buiochi, Elaine Belassiano; Miller, Rita J.; Hartman, Emily; Buiochi, Flavio; Bassani, Rosana A.; Costa, Eduardo T.; O’Brien, William D.

    2013-01-01

    The objective of this study is to investigate cardiac bioeffects resulting from ultrasonic stimulation using a specific set of acoustical parameters. Ten Sprague–Dawley rats were anesthetized and exposed to 1-MHz ultrasound pulses of 3-MPa peak rarefactional pressure and approximately 1% duty factor. The pulse repetition frequency started slightly above the heart rate and was decreased by 1 Hz every 10 s, for a total exposure duration of 30 s. The control group was composed of five rats. Two-way analysis of variance for repeated measures and Bonferroni post hoc tests were used to compare heart rate and ejection fraction, which was used as an index of myocardial contractility. It was demonstrated for the first time that transthoracic ultrasound has the potential to decrease the heart rate by ~20%. The negative chronotropic effect lasted for at least 15 min after ultrasound exposure and there was no apparent gross damage to the cardiac tissue. PMID:23221214

  4. Different nutritional states and autonomic imbalance in childhood.

    PubMed

    Dippacher, S; Willaschek, C; Buchhorn, R

    2014-11-01

    Autonomic imbalance, measured as heart rate variability (HRV), and an increased cardiovascular risk are described for overweight children, as well as for patients with anorexia nervosa. We investigate whether body mass index or actual caloric intake influences HRV. In our cross-sectional study, we compared HRV parameters for a healthy control group (n=52), anorexia nervosa patients (n=17), thin (n=18) and overweight children (n=19). Anorexia nervosa patients showed significantly lower heart rates at night (P<0.001) and significantly higher SDNN (standard deviation of all RR-intervals) (P<0.001 ), whereas overweight children showed an opposing pattern. SDNN and heart rate at night are highly correlated (r=0.89, R(2)=0.79, P<0.001). We conclude that not current body mass index but caloric intake determines HRV. Obesity and anorexia nervosa are characterized by a specific pattern of autonomic imbalance.

  5. Physiological and behavioral parameters of infants' categorization: changes in heart rate and duration of examining across trials.

    PubMed

    Elsner, Birgit; Pauen, Sabina; Jeschonek, Susanna

    2006-11-01

    This report investigates the relations between duration of examining and heart rate (HR) across several trials of an object-examination task. A total of N= 20 11-month-olds were familiarized with a sequence of 10 different exemplars from the same global category (animals or furniture) before they received an exemplar from the contrasting category at test. Consistent with previous findings, HR was lower during states of focused attention (i.e. examining) than during states of casual attention (i.e. looking) or non-looking. Over the familiarization trials, examining stayed about the same, while mean HR increased. At test, examining increased and mean HR decreased, indicating that infants focused their attention on the out-of-category object. Psychophysiological and behavioral measures of attention were systematically related over trials, suggesting that heart rate provides a suitable objective measure to study infants' categorization performance in object-examination tasks.

  6. [Vulnerability to atmospheric and geomagnetic factors of the body functions in healthy male dwellers of the Russian North].

    PubMed

    Markov, A L; Zenchenko, T A; Solonin, Iu G; Boĭko, E R

    2013-01-01

    In April 2009 through to November 2011, a Mars-500 satellite study of Russian Northerners (Syktyvkar citizens) was performed using the standard ECOSAN-2007 procedure evaluating the atmospheric and geomagnetic susceptibility of the main body functional parameters. Seventeen essentially healthy men at the age of 25 to 46 years were investigated. Statistical data treatment included correlation and single-factor analysis of variance. Comparison of the number of statistical correlations of the sum of all functional parameters for participants showed that most often they were sensitive to atmospheric pressure, temperature, relative humidity and oxygen partial pressure (29-35 %), and geomagnetic activity (28 %). Dependence of the functional parameters on the rate of temperature and pressure change was weak and comparable with random coincidence (11 %). Among the hemodynamic parameters, systolic pressure was particularly sensitive to space and terrestrial weather variations (29 %); sensitivity of heart rate and diastolic pressure were determined in 25 % and 21 % of participants, respectively. Among the heart rate variability parameters (HRV) the largest number of statistically reliable correlations was determined for the centralization index (32 %) and high-frequency HRV spectrum (31 %); index of the regulatory systems activity was least dependable (19 %). Life index, maximal breath-holding and Ckibinskaya's cardiorespiratory index are also susceptible. Individual responses of the functional parameters to terrestrial and space weather changes varied with partidpants which points to the necessity of individual approach to evaluation of person's reactions to environmental changes.

  7. Multi-parameter phenotypic profiling: using cellular effects to characterize small-molecule compounds.

    PubMed

    Feng, Yan; Mitchison, Timothy J; Bender, Andreas; Young, Daniel W; Tallarico, John A

    2009-07-01

    Multi-parameter phenotypic profiling of small molecules provides important insights into their mechanisms of action, as well as a systems level understanding of biological pathways and their responses to small molecule treatments. It therefore deserves more attention at an early step in the drug discovery pipeline. Here, we summarize the technologies that are currently in use for phenotypic profiling--including mRNA-, protein- and imaging-based multi-parameter profiling--in the drug discovery context. We think that an earlier integration of phenotypic profiling technologies, combined with effective experimental and in silico target identification approaches, can improve success rates of lead selection and optimization in the drug discovery process.

  8. A Comparative Study on Fetal Heart Rates Estimated from Fetal Phonography and Cardiotocography

    PubMed Central

    Ibrahim, Emad A.; Al Awar, Shamsa; Balayah, Zuhur H.; Hadjileontiadis, Leontios J.; Khandoker, Ahsan H.

    2017-01-01

    The aim of this study is to investigate that fetal heart rates (fHR) extracted from fetal phonocardiography (fPCG) could convey similar information of fHR from cardiotocography (CTG). Four-channel fPCG sensors made of low cost (<$1) ceramic piezo vibration sensor within 3D-printed casings were used to collect abdominal phonogram signals from 20 pregnant mothers (>34 weeks of gestation). A novel multi-lag covariance matrix-based eigenvalue decomposition technique was used to separate maternal breathing, fetal heart sounds (fHS) and maternal heart sounds (mHS) from abdominal phonogram signals. Prior to the fHR estimation, the fPCG signals were denoised using a multi-resolution wavelet-based filter. The proposed source separation technique was first tested in separating sources from synthetically mixed signals and then on raw abdominal phonogram signals. fHR signals extracted from fPCG signals were validated using simultaneous recorded CTG-based fHR recordings.The experimental results have shown that the fHR derived from the acquired fPCG can be used to detect periods of acceleration and deceleration, which are critical indication of the fetus' well-being. Moreover, a comparative analysis demonstrated that fHRs from CTG and fPCG signals were in good agreement (Bland Altman plot has mean = −0.21 BPM and ±2 SD = ±3) with statistical significance (p < 0.001 and Spearman correlation coefficient ρ = 0.95). The study findings show that fHR estimated from fPCG could be a reliable substitute for fHR from the CTG, opening up the possibility of a low cost monitoring tool for fetal well-being. PMID:29089896

  9. Pesticides Exposure and Cardiovascular Hemodynamic Parameters Among Male Workers Involved in Mosquito Control in East Coast of Malaysia.

    PubMed

    Samsuddin, Niza; Rampal, Krishna Gopal; Ismail, Noor Hassim; Abdullah, Nor Zamzila; Nasreen, Hashima E

    2016-02-01

    Research findings have linked exposure to pesticides to an increased risk of cardiovascular (CVS) diseases. Therefore, this study aimed to assess the impact of chronic mix-pesticides exposure on CVS hemodynamic parameters. A total of 198 male Malay pesticide-exposed and 195 male Malay nonexposed workers were examined. Data were collected through exposure-matrix assessment, questionnaire, blood analyses, and CVS assessment. Explanatory variables comprised of lipid profiles, paraoxonase 1 (PON1), and oxidized low-density lipoprotein (ox-LDL). Outcome measures comprised of brachial and aortic diastolic blood pressure (DBP) and systolic BP (SBP), heart rate, and pulse wave velocity (PWV). Linear regressions identified the B coefficient showing how many units of CVS parameters are associated with each unit of covariates. Diazoxonase was significantly lower and ox-LDL was higher among pesticide-exposed workers than the comparison group. The final multivariate linear regression model revealed that age, body mass index (BMI), smoking, and pesticide exposure were independent predictors of brachial and aortic DBP and SBP. Pesticide exposure was also associated with heart rate, but not with PWV. Lipid profiles, PON1 enzymes, and ox-LDL showed no association with any of the CVS parameters. Chronic mix-pesticide exposure among workers involved in mosquito control has possible association with depression of diazoxonase and the increase in ox-LDL, brachial and aortic DBP and SBP, and heart rate. This study raises concerns that those using pesticides may be exposed to hitherto unrecognized CVS risks among others. If this is confirmed by further studies, greater efforts will be needed to protect these workers. © American Journal of Hypertension, Ltd 2015. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. The impact of major depression on heart rate variability and endothelial dysfunction in patients with stable coronary artery disease.

    PubMed

    Aydin Sunbul, Esra; Sunbul, Murat; Gulec, Huseyin

    Depression is an independent risk factor in cardiovascular diseases. Changes in the cardiac autonomic functions and pro-inflammatory processes are potential biological factors. Endothelial dysfunction plays an important role in the etiopathogenesis of atherosclerosis. Our objective was to evaluate the impact of major depression on heart rate variability and endothelial dysfunction in patients with stable CAD. The study group included 65 CAD patients with a diagnosis of major depression and 54 CAD patients without major depression. All study population underwent transthoracic echocardiography, measurement of flow mediated dilatation (FMD) and 24-h holter recording for heart rate variability (HRV). Blood samples were drawn to determine the inflammatory parameters. Severity of depressive episode was assessed by Montgomery-Asberg Depression Scale (MADRS). The distribution of age and sex was similar in the patient and control groups (P=0.715, 0.354, respectively). There was no significant difference in medications used between the groups. Echocardiographic parameters were similar between the groups. Inflammatory parameters were also similar between the groups. HRV parameters were significantly lower in the patient group than controls. The absolute FMD value and percentage FMD were significantly lower in the patient group than controls (P<0.001). The MADRS score correlated with pNN50 in both groups (P<0.05), and with FMD in the control group (P<0.001), even after adjusting for age and gender (P<0.001). MADRS score was an independent predictor of pNN50 level, percentage and absolute FMD values regardless of age and gender. Clinician should pay more attention for evaluation of depressive patients with CAD. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Verbal communication with the Blom low profile and Passy-Muir one-way tracheotomy tube speaking valves.

    PubMed

    Adam, Stewart I; Srinet, Prateek; Aronberg, Ryan M; Rosenberg, Graeme; Leder, Steven B

    2015-01-01

    To investigate physiologic parameters, voice production abilities, and functional verbal communication ratings of the Blom low profile voice inner cannula and Passy-Muir one-way tracheotomy tube speaking valves. Case series with planned data collection. Large, urban, tertiary care teaching hospital. Referred sample of 30 consecutively enrolled adults requiring a tracheotomy tube and tested with Blom and Passy-Muir valves. Physiologic parameters recorded were oxygen saturation, respiration rate, and heart rate. Voice production abilities included maximum voice intensity in relation to ambient room noise and maximum phonation duration of the vowel/a/. Functional verbal communication was determined from randomized and blinded listener ratings of counting 1-10, saying the days of the week, and reading aloud the sentence, "There is according to legend a boiling pot of gold at one end." There were no significant differences (p>0.05) between the Blom and Passy-Muir valves for the physiologic parameters of oxygen saturation, respiration rate, and heart rate; voice production abilities of both maximum intensity and duration of/a/; and functional verbal communication ratings. Both valves allowed for significantly greater maximum voice intensity over ambient room noise (p<0.001). The Blom low profile voice inner cannula and Passy-Muir one-way speaking valves exhibited equipoise regarding patient physiologic parameters, voice production abilities, and functional verbal communication ratings. Readers will understand the importance of verbal communication for patients who require a tracheotomy tube; will be able to determine the differences between the Blom low profile voice inner cannula and Passy-Muir one-way tracheotomy tube speaking valves; and will be confident in knowing that both the Blom and Passy-Muir one-way tracheotomy tube speaking valves are equivalent regarding physiological functioning and speech production abilities. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Effects of Aerobic Exercise Based upon Heart Rate at Aerobic Threshold in Obese Elderly Subjects with Type 2 Diabetes

    PubMed Central

    Donini, Lorenzo Maria

    2015-01-01

    In obese diabetic subjects, a correct life style, including diet and physical activity, is part of a correct intervention protocol. Thus, the aim of this study was to evaluate the effects of aerobic training intervention, based on heart rate at aerobic gas exchange threshold (AerTge), on clinical and physiological parameters in obese elderly subjects with type 2 diabetes (OT2DM). Thirty OT2DM subjects were randomly assigned to an intervention (IG) or control group (CG). The IG performed a supervised aerobic exercise training based on heart rate at AerTge whereas CG maintained their usual lifestyle. Anthropometric measures, blood analysis, peak oxygen consumption (V˙O2peak), metabolic equivalent (METpeak), work rate (WRpeak), and WRAerTge were assessed at baseline and after intervention. After training, patients enrolled in the IG had significantly higher (P < 0.001) V˙O2peak, METpeak, WRpeak, and WRAerTge and significantly lower (P < 0.005) weight, BMI, %FM, and waist circumference than before intervention. Both IG and CG subjects had lower glycated haemoglobin levels after intervention period. No significant differences were found for all the other parameters between pre- and posttraining and between groups. Aerobic exercise prescription based upon HR at AerTge could be a valuable physical intervention tool to improve the fitness level and metabolic equilibrium in OT2DM patients. PMID:26089890

  13. Evaluation of the relationship between motion sickness symptomatology and blood pressure, heart rate, and body temperature

    NASA Technical Reports Server (NTRS)

    Graybiel, A.; Lackner, J. R.

    1980-01-01

    This study investigated the relationship between the development of symptoms of motion sickness and changes in blood pressure, heart rate, and body temperature. Twelve subjects were each evaluated four times using the vestibular-visual interaction test (Graybiel and Lackner, 1980). The results were analyzed both within and across individual subjects. Neither a systematic group nor consistent individual relationship was found between the physiological parameters and the appearance of symptoms of motion sickness. These findings suggest that biofeedback control of the physiological variables studied is not likely to prevent the expression of motion sickness symptomatology.

  14. Diabetes mellitus is associated with adverse structural and functional cardiac remodelling in chronic heart failure with reduced ejection fraction.

    PubMed

    Walker, Andrew Mn; Patel, Peysh A; Rajwani, Adil; Groves, David; Denby, Christine; Kearney, Lorraine; Sapsford, Robert J; Witte, Klaus K; Kearney, Mark T; Cubbon, Richard M

    2016-09-01

    Diabetes mellitus is associated with an increased risk of death and hospitalisation in patients with chronic heart failure. Better understanding of potential underlying mechanisms may aid the development of diabetes mellitus-specific chronic heart failure therapeutic strategies. Prospective observational cohort study of 628 patients with chronic heart failure associated with left ventricular systolic dysfunction receiving contemporary evidence-based therapy. Indices of cardiac structure and function, along with symptoms and biochemical parameters, were compared in patients with and without diabetes mellitus at study recruitment and 1 year later. Patients with diabetes mellitus (24.2%) experienced higher rates of all-cause [hazard ratio, 2.3 (95% confidence interval, 1.8-3.0)] and chronic heart failure-specific mortality and hospitalisation despite comparable pharmacological and device-based therapies. At study recruitment, patients with diabetes mellitus were more symptomatic, required greater diuretic doses and more frequently had radiologic evidence of pulmonary oedema, despite higher left ventricular ejection fraction. They also exhibited echocardiographic evidence of increased left ventricular wall thickness and pulmonary arterial pressure. Diabetes mellitus was associated with reduced indices of heart rate variability and increased heart rate turbulence. During follow-up, patients with diabetes mellitus experienced less beneficial left ventricular remodelling and greater deterioration in renal function. Diabetes mellitus is associated with features of adverse structural and functional cardiac remodelling in patients with chronic heart failure. © The Author(s) 2016.

  15. The effect of vocal and instrumental music on cardio respiratory variables, energy expenditure and exertion levels during sub maximal treadmill exercise.

    PubMed

    Savitha, D; Sejil, T V; Rao, Shwetha; Roshan, C J; Roshan, C J

    2013-01-01

    The purpose of the study was to investigate the effect of vocal and instrumental music on various physiological parameters during submaximal exercise. Each subject underwent three sessions of exercise protocol without music, with vocal music, and instrumental versions of same piece of music. The protocol consisted of 10 min treadmill exercise at 70% HR(max) and 20 min of recovery. Minute to minute heart rate and breath by breath recording of respiratory parameters, rate of energy expenditure and perceived exertion levels were measured. Music, irrespective of the presence or absence of lyrics, enabled the subjects to exercise at a significantly lower heart rate and oxygen consumption, reduced the metabolic cost and perceived exertion levels of exercise (P < 0.05). There was faster recovery of systolic and diastolic blood pressures and exertion levels during the post exercise period. Music having a relaxant effect could have probably increased the parasympathetic activation leading to these effects.

  16. Evaluation of Left Ventricular Diastolic Dysfunction with Early Systolic Dysfunction Using Two-Dimensional Speckle Tracking Echocardiography in Canine Heart Failure Model.

    PubMed

    Wu, Wei-Chun; Ma, Hong; Xie, Rong-Ai; Gao, Li-Jian; Tang, Yue; Wang, Hao

    2016-04-01

    This study evaluated the role of two-dimensional speckle tracking echocardiography (2DSTE) for predicting left ventricular (LV) diastolic dysfunction in pacing-induced canine heart failure. Pacing systems were implanted in 8 adult mongrel dogs, and continuous rapid right ventricular pacing (RVP, 240 beats/min) was maintained for 2 weeks. The obtained measurements from 2DSTE included global strain rate during early diastole (SRe) and during late diastole (SRa) in the longitudinal (L-SRe, L-SRa), circumferential (C-SRe, C-SRa), and radial directions (R-SRe, R-SRa). Changes in heart morphology were observed by light microscopy and transmission electron microscopy at 2 weeks. The onset of LV diastolic dysfunction with early systolic dysfunction occurred 3 days after RVP initiation. Most of the strain rate imaging indices were altered at 1 or 3 days after RVP onset and continued to worsen until heart failure developed. Light and transmission electron microscopy showed myocardial vacuolar degeneration and mitochondrial swelling in the left ventricular at 2 weeks after RVP onset. Pearson's correlation analysis revealed that parameters of conventional echocardiography and 2DSTE showed moderate correlation with LV pressure parameters, including E/Esep' (r = 0.58, P < 0.01), L-SRe (r = -0.58, P < 0.01), E/L-SRe (r = 0.65, P < 0.01), and R-SRe (r = 0.53, P < 0.01). ROC curves analysis showed that these indices of conventional echocardiography and strain rate imaging could effectively predict LV diastolic dysfunction (area under the curve: E/Esep' 0.78; L-SRe 0.84; E/L-SRe 0.80; R-SRe 0.80). 2DSTE was a sensitive and accurate technique that could be used for predicting LV diastolic dysfunction in canine heart failure model. © 2015, Wiley Periodicals, Inc.

  17. Heart CT scan

    MedlinePlus

    ... Computed tomography scan - heart; Calcium scoring; Multi-detector CT scan - heart; Electron beam computed tomography - heart; Agatston ... table that slides into the center of the CT scanner. You will lie on your back with ...

  18. Elucidation of the Strongest Predictors of Cardiovascular Events in Patients with Heart Failure.

    PubMed

    Fukuda, Hiroki; Shindo, Kazuhiro; Sakamoto, Mari; Ide, Tomomi; Kinugawa, Shintaro; Fukushima, Arata; Tsutsui, Hiroyuki; Ito, Shin; Ishii, Akira; Washio, Takashi; Kitakaze, Masafumi

    2018-06-20

    In previous retrospective studies, we identified the 50 most influential clinical predictors of cardiovascular outcomes in patients with heart failure (HF). The present study aimed to use the novel limitless-arity multiple-testing procedure to filter these 50 clinical factors and thus yield combinations of no more than four factors that could potentially predict the onset of cardiovascular events. A Kaplan-Meier analysis was used to investigate the importance of the combinations. In a multi-centre observational trial, we prospectively enrolled 213 patients with HF who were hospitalized because of exacerbation, discharged according to HF treatment guidelines and observed to monitor cardiovascular events. After the observation period, we stratified patients according to whether they experienced cardiovascular events (rehospitalisation or cardiovascular death). Among 77,562 combinations of fewer than five clinical parameters, we identified 151 combinations that could potentially explain the occurrence of cardiovascular events. Of these, 145 combinations included the use of inotropic agents, whereas the remaining 6 included the use of diuretics without bradycardia or tachycardia, suggesting that the high probability of cardiovascular events is exclusively determined by these two clinical factors. Importantly, Kaplan-Meier curves demonstrated that the use of inotropes or of diuretics without bradycardia or tachycardia were independent predictors of a markedly worse cardiovascular prognosis. Patients treated with either inotropic agents or diuretics without bradycardia or tachycardia were at a higher risk of cardiovascular events. The uses of these drugs, regardless of heart rate, are the strongest clinical predictors of cardiovascular events in patients with HF. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  19. Reduction of coenzyme q10 content: a possible effect of isoproterenol on heart failure and myocardial infarction in rat.

    PubMed

    Khorrami, A; Garjani, A; Ghanbarzadeh, S; Andalib, S

    2014-04-01

    Myocardial infarction (MI) was induced by subcutaneous injection of isoproterenol (ISO) to investigate the effect of ISO on Coenzyme Q10 (CoQ10) content of myocardium and subsequent effects on lipid peroxidation, electrocardiogram pattern and hemodynamic parameters of the rat's heart.36 male Wistar rats were divided randomly into 6 groups. To induce heart failure (HF) and MI, 10 and 100 mg/kg of ISO was administered subcutaneously for 10 and 2 consecutive days, respectively. The effects of ISO on myocardium CoQ10 content, concentration of malondialdehyde, ECG pattern and hemodynamic parameters of heart were analyzed.ISO-treated rats showed significant alteration in heart hemodynamic parameters such as reduction of left-ventricular systolic pressure, maximum and minimum rate of developed left ventricular pressure, besides increase of left ventricular end-diastolic pressure. Significant depletion of heart CoQ10 content (from 4.57 and 4.55 µg/100 mg tissue in control groups to 2.85 and 2.89 µg/100 mg tissue in ISO-induced HF and MI groups respectively) and increase in tissue levels of malondialdehyde (47.1 and 53.8 nmol/100 mg tissue in ISO-induced HF and MI groups, respectively) were also observed in ISO-treated animals compared with the normal animals (17.4 and 18.8 nmol/100 mg tissue in control groups, respectively). Additionally CoQ10 improved ISO effects on hemodynamic parameters and ECG pattern in ISO-induced HF and myocardial injury.The present findings have demonstrated that the cardiotoxic effects of ISO such as oxidative damage and hemodynamic declination might be related to depletion of CoQ10 concentration. © Georg Thieme Verlag KG Stuttgart · New York.

  20. Phase coupling in the cardiorespiratory interaction.

    PubMed

    Bahraminasab, A; Kenwright, D; Stefanovska, A; Ghasemi, F; McClintock, P V E

    2008-01-01

    Markovian analysis is applied to derive nonlinear stochastic equations for the reconstruction of heart rate and respiration rate variability data. A model of their 'phase' interactions is obtained for the first time, thereby gaining new insights into the strength and direction of the cardiorespiratory phase coupling. The reconstructed model can reproduce synchronisation phenomena between the cardiac and the respiratory systems, including switches in synchronisation ratio. The technique is equally applicable to the extraction of the multi-dimensional couplings between many interacting subsystems.

  1. The future of telemedicine for the management of heart failure patients: a Consensus Document of the Italian Association of Hospital Cardiologists (A.N.M.C.O), the Italian Society of Cardiology (S.I.C.) and the Italian Society for Telemedicine and eHealth (Digital S.I.T.)

    PubMed Central

    Casolo, Giancarlo; Gulizia, Michele Massimo; Aspromonte, Nadia; Scalvini, Simonetta; Mortara, Andrea; Alunni, Gianfranco; Ricci, Renato Pietro; Mantovan, Roberto; Russo, Giancarmine; Gensini, Gian Franco; Romeo, Francesco

    2017-01-01

    Abstract Telemedicine applied to heart failure patients is a tool for recording and providing remote transmission, storage and interpretation of cardiovascular parameters and/or useful diagnostic images to allow for intensive home monitoring of patients with advanced heart failure, or during the vulnerable post-acute phase, to improve patient’s prognosis and quality of life. Recently, several meta-analyses have shown that telemedicine-supported care pathways are not only effective but also economically advantageous. Benefits seem to be substantial, with a 30–35% reduction in mortality and 15–20% decrease in hospitalizations. Patients implanted with cardiac devices can also benefit from an integrated remote clinical management since all modern devices can transmit technical and diagnostic data. However, telemedicine may provide benefits to heart failure patients only as part of a shared and integrated multi-disciplinary and multi-professional ‘chronic care model’. Moreover, the future development of remote telemonitoring programs in Italy will require the primary use of products certified as medical devices, validated organizational solutions as well as legislative and administrative adoption of new care methods and the widespread growth of clinical care competence to remotely manage the complexity of chronicity. Through this consensus document, Italian Cardiology reaffirms its willingness to contribute promoting a new phase of qualitative assessment, standardization of processes and testing of telemedicine-based care models in heart failure. By recognizing the relevance of telemedicine for the care of non-hospitalized patients with heart failure, its strategic importance for the design of innovative models of care, and the many challenges and opportunities it raises, ANMCO and SIC through this document report a consensus on the main directions for its widespread and sustainable clinical implementation PMID:28751839

  2. The future of telemedicine for the management of heart failure patients: a Consensus Document of the Italian Association of Hospital Cardiologists (A.N.M.C.O), the Italian Society of Cardiology (S.I.C.) and the Italian Society for Telemedicine and eHealth (Digital S.I.T.).

    PubMed

    Di Lenarda, Andrea; Casolo, Giancarlo; Gulizia, Michele Massimo; Aspromonte, Nadia; Scalvini, Simonetta; Mortara, Andrea; Alunni, Gianfranco; Ricci, Renato Pietro; Mantovan, Roberto; Russo, Giancarmine; Gensini, Gian Franco; Romeo, Francesco

    2017-05-01

    Telemedicine applied to heart failure patients is a tool for recording and providing remote transmission, storage and interpretation of cardiovascular parameters and/or useful diagnostic images to allow for intensive home monitoring of patients with advanced heart failure, or during the vulnerable post-acute phase, to improve patient's prognosis and quality of life. Recently, several meta-analyses have shown that telemedicine-supported care pathways are not only effective but also economically advantageous. Benefits seem to be substantial, with a 30-35% reduction in mortality and 15-20% decrease in hospitalizations. Patients implanted with cardiac devices can also benefit from an integrated remote clinical management since all modern devices can transmit technical and diagnostic data. However, telemedicine may provide benefits to heart failure patients only as part of a shared and integrated multi-disciplinary and multi-professional 'chronic care model'. Moreover, the future development of remote telemonitoring programs in Italy will require the primary use of products certified as medical devices, validated organizational solutions as well as legislative and administrative adoption of new care methods and the widespread growth of clinical care competence to remotely manage the complexity of chronicity. Through this consensus document, Italian Cardiology reaffirms its willingness to contribute promoting a new phase of qualitative assessment, standardization of processes and testing of telemedicine-based care models in heart failure. By recognizing the relevance of telemedicine for the care of non-hospitalized patients with heart failure, its strategic importance for the design of innovative models of care, and the many challenges and opportunities it raises, ANMCO and SIC through this document report a consensus on the main directions for its widespread and sustainable clinical implementation.

  3. Increase of Short-Term Heart Rate Variability Induced by Blood Pressure Measurements during Ambulatory Blood Pressure Monitoring.

    PubMed

    Frigy, Attila; Magdás, Annamária; Moga, Victor-Dan; Coteț, Ioana Georgiana; Kozlovszky, Miklós; Szilágyi, László

    2017-01-01

    Objective. The possible effect of blood pressure measurements per se on heart rate variability (HRV) was studied in the setting of concomitant ambulatory blood pressure monitoring (ABPM) and Holter ECG monitoring (HM). Methods. In 25 hypertensive patients (14 women and 11 men, mean age: 58.1 years), 24-hour combined ABPM and HM were performed. For every blood pressure measurement, 2-minute ECG segments (before, during, and after measurement) were analyzed to obtain time domain parameters of HRV: SDNN and rMSSD. Mean of normal RR intervals (MNN), SDNN/MNN, and rMSSD/MNN were calculated, too. Parameter variations related to blood pressure measurements were analyzed using one-way ANOVA with multiple comparisons. Results. 2281 measurements (1518 during the day and 763 during the night) were included in the analysis. Both SDNN and SDNN/MNN had a constant (the same for 24-hour, daytime, and nighttime values) and significant change related to blood pressure measurements: an increase during measurements and a decrease after them ( p < 0.01 for any variation). Conclusion. In the setting of combined ABPM and HM, the blood pressure measurement itself produces an increase in short-term heart rate variability. Clarifying the physiological basis and the possible clinical value of this phenomenon needs further studies.

  4. Music therapy can lower the heart rates of severely sick children.

    PubMed

    Uggla, L; Bonde, L O; Svahn, B M; Remberger, M; Wrangsjö, B; Gustafsson, B

    2016-10-01

    Paediatric recipients of haematopoietic stem cell transplants (HSCT) are at increased risk of developing post-traumatic stress disorder (PTSD), and there is a need to identify interventions that can alleviate stress in this group. The aim of this study was to examine the previously unexplored effect of music therapy on children undergoing HSCT, by analysing physiological parameters and comparing them with a control group. We performed a randomised clinical pilot study of 24 patients up to the age of 16 undergoing HSCT at Karolinska University Hospital, Huddinge, Sweden. Music therapy, including expressive and receptive elements, was performed twice a week in the treatment group and compared to standard care in the control group. Physiological parameters were evaluated according to the hospital's protocols. The music therapy group had significantly reduced evening heart rates compared to the control group (p < 0.001), and the effect was sustainable for four to eight hours after the intervention. There were no significant differences in saturation or blood pressure observed between the groups. Music therapy significantly lowered the heart rate of children undergoing HSCT for at least four to eight hours, indicating reduced stress levels and potentially lowering the risk of developing PTSD. ©2016 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  5. Weather-induced ischemia and arrhythmia in patients undergoing cardiac rehabilitation: another difference between men and women

    NASA Astrophysics Data System (ADS)

    Schneider, Alexandra; Schuh, Angela; Maetzel, Friedrich-Karl; Rückerl, Regina; Breitner, Susanne; Peters, Annette

    2008-07-01

    Given the accumulating evidence that people with underlying heart disease are a particularly vulnerable group for triggers like changing meteorological parameters, the objective of this longitudinal study was to analyze the influence of weather parameters on blood pressure, arrhythmia and ischemia in cardiovascular patients. A panel study with repeated measurements was conducted in a rehabilitation clinic in Timmendorfer Strand (Baltic Sea, Germany) with 872 cardiovascular patients. Heart rate, blood pressure and electrocardiography changes were measured during repeated bicycle ergometries. Generalized Estimating Equations were used for regression analyses of immediate, delayed and cumulative influences of the daily measured meteorological data. For men, a decrease in air temperature and in water vapor pressure doubled the risk of ST-segment depression during ergometry [odds ratio (OR) for 1 day delay: 1.88 (1.24; 2.83) for air temperature] with a delay of 1-2 days. For women, an increase of their heart rate before the start of the ergometry [same day: 4.36 beats/min (0.99; 7.74) for air temperature] and a 2- to 3-fold higher risk for ventricular ectopic beats [1 day delay: OR 2.43 (1.17; 5.05) for air temperature] was observed with an increase in temperature and water vapor pressure in almost all analyzed time-windows. The study indicates that meteorological parameters can induce changes in heart function which may lead to adverse cardiovascular events especially in susceptible, diseased individuals. The observed effect on ST-segment depression could be a link between the association of weather changes and cardiovascular morbidity and mortality.

  6. Effects of simvastatin on cardiohemodynamic responses to ischemia-reperfusion in isolated rat hearts.

    PubMed

    Zheng, Xia; Hu, Shen-Jiang

    2006-03-01

    Simvastatin, a 3-hydroxy-3-methylglutaryl coenzyme A (HMG-CoA) reductase inhibitor, has long been thought to exert its benefits by reducing cholesterol synthesis, and has been shown to significantly reduce cardiovascular events and mortality in patients with or without coronary artery disease. However, it is still unknown whether acute administration of simvastatin beneficially affects the cardiac function prior or during ischemia-reperfusion. The aim of this study is to evaluate the cardioprotective effect of acute simvastatin treatment on isolated rat hearts or isolated ischemia-reperfusion hearts. Hearts were isolated from male Sprague-Dawley rats and attached to a Langendorff apparatus. The isolated hearts with or without ischemia (15 min) and reperfusion (60 min) were perfused with different concentrations of simvastatin. The parameters of cardiac function (such as left ventricular developed pressure [LVDP], +dp/dt max, and -dp/dt max), heart rate, and coronary flow were recorded. Simvastatin (3-30 micromol/l) significantly increased LVDP, +dp/dt max, and -dp/dt max in isolated rat hearts perfused for 60 min. Heart rate was depressed by 30 micromol/l simvastatin and the coronary flow was increased by 10 and 30 micromol/l simvastatin. At a concentration of 100 micromol/l simvastatin, worsening of heart function and subsequent cardiac arrest occurred. Administration of simvastatin (3-30 micromol/l) significantly preserved cardiac function detected by LVDP, +dp/dt max, and -dp/dt max in the isolated ischemia/reperfused (15/60 min) rat hearts. Simvastatin also significantly decreased heart rate at 30 micromol/l, and increased coronary flow at 10 and 30 micromol/l in these rat hearts. However, the protective effect of simvastatin reverted to increased damage at 100 micromol/l. Only 3 micromol/l simvastatin pretreatment before 15/60 min ischemia-reperfusion altered LVDP, +dp/dt max, and -dp/dt max. Both heart rate and coronary flow were unaltered after simvastatin pretreatment. Since simvastatin at a concentration lower than 100 micromol/l exerted beneficial effects on cardiac function in isolated perfused rat hearts, it could be applied just after myocardial ischemia and reperfusion.

  7. Effects of hiking at moderate and low altitude on cardiovascular parameters in male patients with metabolic syndrome: Austrian Moderate Altitude Study.

    PubMed

    Neumayr, Günther; Fries, Dietmar; Mittermayer, Markus; Humpeler, Egon; Klingler, Anton; Schobersberger, Wolfgang; Spiesberger, Reinhard; Pokan, Rochus; Schmid, Peter; Berent, Robert

    2014-09-01

    Physical activity is a cornerstone in therapy for patients with metabolic syndrome. Walking and hiking in a mountain scenery represents an ideal approach to make them move. The Austrian Moderate Altitude Study (AMAS) 2000 main study is a randomized controlled trial to investigate the cardiovascular effects of hiking at moderate altitude on patients with metabolic syndrome compared with a control group at low altitude, to assess a potential altitude-specific effect. Seventy-one male patients with metabolic syndrome were randomly assigned to a moderate altitude group (at 1700 m), with 36 participants, or to a low altitude group (at 200 m), with 35 participants. The 3-week vacation program included 12 hiking tours (4 per week, average duration 2.5 hours, intensity 55% to 65% of heart rate maximum). Physical parameters, performance capacity, 24-hour blood pressure, and heart rate profiles were obtained before, during, and after the stay. In both groups, we found a significant mean weight loss of -3.13 kg; changes in performance capacity were minor. Systolic, diastolic, and mean arterial pressures and circadian heart rate profiles were significantly reduced in both groups, with no differences between them. Consequently, the pressure-rate product was reduced as well. All study participants tolerated the vacation well without any adverse events. A 3-week hiking vacation at moderate or low altitude is safe for patients with metabolic syndrome and provides several improvements in their cardiovascular parameters. The cardiovascular benefits achieved are more likely to be the result of regular physical activity than the altitude-specific effect of a mountain environment. Copyright © 2014 Wilderness Medical Society. Published by Elsevier Inc. All rights reserved.

  8. [Evaluation of Slavic continuity for electrocardiograph (ECG)-gated non-helical scan using multi detector-row computed tomography with 64 data acquisition system].

    PubMed

    Shiotani, Masataka; Ogawa, Masato; Watanabe, Ryo; Shinohara, Tamotsu

    2012-01-01

    Multi detector-row computed tomography with 64 data acquisition systems are widely used for coronary CT angiography with an electrocardiograph (ECG) gated helical scan (HS). Step and shoot with ECG gated non-helical scan (snap shot pulse: SSP) could reduce exposure dose but banding artifact-like discontinuity was observed between adjacent slabs on volume rendering (VR) and curved planner reconstruction (CPR). Therefore, we investigated the factors that influence continuity of VR and CPR images by calculating image properties of Z-axis direction of slab. The observer performance studies were performed for evaluating continuity of simulated blood vessels of VR and CPR images at simulated heart rates: 50, 55, 57 and 60 beat per minute (bpm). As a result, the value of SD at both slab edges in SSP were 20.5% lower than middle part of slab and differences of value of SD were up to 4.4 between adjacent slab edges. Slice thickness of both slab edges were 20.3% thinner than that of the peripheral part of slab. At the border of the adjacent slab, the position of the simulated blood vessel was shifted. VR images of SSP at 57 bpm was indicated as the highest score and HS was significantly superior to SSP at 55 and 60 bpm (p<0.05). In CPR images, there were no significant differences at all simulated heart rates. In conclusion, we considered that VR images of SSP were influenced heart rates except 57 bpm (resonance case) and there was little difference of visibility for discontinuity of both CPR images obtained by SSP and HS.

  9. Observing continuous change in heart rate variability and photoplethysmography-derived parameters during the process of pain production/relief with thermal stimuli.

    PubMed

    Ye, Jing-Jhao; Lee, Kuan-Ting; Lin, Jing-Siang; Chuang, Chiung-Cheng

    2017-01-01

    Continuously monitoring and efficiently managing pain has become an important issue. However, no study has investigated a change in physiological parameters during the process of pain production/relief. This study modeled the process of pain production/relief using ramped thermal stimulation (no pain: 37°C water, process of pain production: a heating rate of 1°C/min, and subject feels pain: water kept at the painful temperature for each subject, with each segment lasting 10 min). In this duration, the variation of the heat rate variability and photoplethysmography-derived parameters was observed. A total of 40 healthy individuals participated: 30 in the trial group (14 males and 16 females with a mean age of 22.5±1.9 years) and 10 in the control group (7 males and 3 females with a mean age of 22.5±1.3 years). The results showed that the numeric rating scale value was 5.03±1.99 when the subjects felt pain, with a temperature of 43.54±1.70°C. Heart rate, R-R interval, low frequency, high frequency, photoplethysmography amplitude, baseline, and autonomic nervous system state showed significant changes during the pain production process, but these changes differed during the period Segment D (painful temperature 10: min). In summary, the study observed that physiological parameters changed qualitatively during the process of pain production and relief and found that the high frequency, low frequency, and photoplethysmography parameters seemed to have different responses in four situations (no pain, pain production, pain experienced, and pain relief). The trends of these variations may be used as references in the clinical setting for continuously observing pain intensity.

  10. An automatic method to calculate heart rate from zebrafish larval cardiac videos.

    PubMed

    Kang, Chia-Pin; Tu, Hung-Chi; Fu, Tzu-Fun; Wu, Jhe-Ming; Chu, Po-Hsun; Chang, Darby Tien-Hao

    2018-05-09

    Zebrafish is a widely used model organism for studying heart development and cardiac-related pathogenesis. With the ability of surviving without a functional circulation at larval stages, strong genetic similarity between zebrafish and mammals, prolific reproduction and optically transparent embryos, zebrafish is powerful in modeling mammalian cardiac physiology and pathology as well as in large-scale high throughput screening. However, an economical and convenient tool for rapid evaluation of fish cardiac function is still in need. There have been several image analysis methods to assess cardiac functions in zebrafish embryos/larvae, but they are still improvable to reduce manual intervention in the entire process. This work developed a fully automatic method to calculate heart rate, an important parameter to analyze cardiac function, from videos. It contains several filters to identify the heart region, to reduce video noise and to calculate heart rates. The proposed method was evaluated with 32 zebrafish larval cardiac videos that were recording at three-day post-fertilization. The heart rate measured by the proposed method was comparable to that determined by manual counting. The experimental results show that the proposed method does not lose accuracy while largely reducing the labor cost and uncertainty of manual counting. With the proposed method, researchers do not have to manually select a region of interest before analyzing videos. Moreover, filters designed to reduce video noise can alleviate background fluctuations during the video recording stage (e.g. shifting), which makes recorders generate usable videos easily and therefore reduce manual efforts while recording.

  11. Energy expenditure in frontotemporal dementia: a behavioural and imaging study

    PubMed Central

    Ahmed, Rebekah M; Landin-Romero, Ramon; Collet, Tinh-Hai; van der Klaauw, Agatha A; Devenney, Emma; Henning, Elana; Kiernan, Matthew C; Piguet, Olivier; Farooqi, I Sadaf; Hodges, John R

    2017-01-01

    Abstract See Finger (doi:10.1093/aww312) for a scientific commentary on this article. Abnormal eating behaviour and metabolic parameters including insulin resistance, dyslipidaemia and body mass index are increasingly recognized as important components of neurodegenerative disease and may contribute to survival. It has previously been established that behavioural variant frontotemporal dementia is associated with abnormal eating behaviour characterized by increased sweet preference. In this study, it was hypothesized that behavioural variant frontotemporal dementia might also be associated with altered energy expenditure. A cohort of 19 patients with behavioural variant frontotemporal dementia, 13 with Alzheimer’s disease and 16 (age- and sex-matched) healthy control subjects were studied using Actiheart devices (CamNtech) to assess resting and stressed heart rate. Actiheart devices were fitted for 7 days to measure sleeping heart rate, activity levels, and resting, active and total energy expenditure. Using high resolution structural magnetic resonance imaging the neural correlates of increased resting heart rate were investigated including cortical thickness and region of interest analyses. In behavioural variant frontotemporal dementia, resting (P = 0.001), stressed (P = 0.037) and sleeping heart rate (P = 0.038) were increased compared to control subjects, and resting heart rate (P = 0.020) compared to Alzheimer disease patients. Behavioural variant frontotemporal dementia was associated with decreased activity levels compared to controls (P = 0.002) and increased resting energy expenditure (P = 0.045) and total energy expenditure (P = 0.035). Increased resting heart rate correlated with behavioural (Cambridge Behavioural Inventory) and cognitive measures (Addenbrooke’s Cognitive Examination). Increased resting heart rate in behavioural variant frontotemporal dementia correlated with atrophy involving the mesial temporal cortex, insula, and amygdala, regions previously suggested to be involved exclusively in social and emotion processing in frontotemporal dementia. These neural correlates overlap the network involved in eating behaviour in frontotemporal dementia, suggesting a complex interaction between eating behaviour, autonomic function and energy homeostasis. As such the present study suggests that increased heart rate and autonomic changes are prevalent in behavioural variant frontotemporal dementia, and are associated with changes in energy expenditure. An understanding of these changes and neural correlates may have potential relevance to disease progression and prognosis. PMID:27789521

  12. Is There an Association Between Markers of Cardiovascular Autonomic Dysfunction at Discharge From Rehabilitation and Participation 1 and 5 Years Later in Individuals With Spinal Cord Injury?

    PubMed

    Rianne Ravensbergen, H J; de Groot, Sonja; Post, Marcel W; Bongers-Janssen, Helma M; van der Woude, Lucas H; Claydon, Victoria E

    2016-09-01

    To determine whether physical activity and participation 1 and 5 years after discharge are associated with measures of cardiovascular autonomic function: prevalence of hypotension and reduced peak heart rate at discharge from initial inpatient spinal cord injury (SCI) rehabilitation. Prospective cohort study. Rehabilitation centers. Individuals with SCI (N=146). Not applicable. We recorded markers of cardiovascular autonomic dysfunction (resting blood pressure and peak heart rate) and personal and lesion characteristics at the time of discharge from rehabilitation. Parameters for participation (social health status dimension of the Sickness Impact Profile) and physical activity (Physical Activity Scale for Individuals with Physical Disabilities [PASIPD]) were measured 1 and 5 years after discharge. Effects of prevalence of cardiovascular autonomic dysfunction were analyzed using linear regression analysis while correcting for possible confounders. We found no significant association between hypotension and social health status dimension of the Sickness Impact Profile or PASIPD, either at 1 or at 5 years after discharge. A significant association between peak heart rate and social health status dimension of the Sickness Impact Profile was found at 1 year after discharge, showing poorer participation in individuals with low peak heart rate (ie, cardiovascular autonomic dysfunction). The unadjusted relation between peak heart rate and the social health status dimension of the Sickness Impact Profile was significant at 5 years, but not when adjusted for confounders. We found associations between peak heart rate and PASIPD for both 1 and 5 years after discharge; however, these were not significant after correction for potential confounding factors. Autonomic dysfunction after SCI is a crucial factor influencing quality of life. We found that cardiovascular autonomic impairment, assessed from low peak heart rate, was associated with reduced participation after 1 year. The results suggest that peak heart rate at discharge from rehabilitation after SCI should be used to identify those needing additional support to facilitate physical activity and participation after discharge. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  13. Changes induced by music therapy to physiologic parameters in patients with dental anxiety.

    PubMed

    Mejía-Rubalcava, Cynthia; Alanís-Tavira, Jorge; Mendieta-Zerón, Hugo; Sánchez-Pérez, Leonor

    2015-11-01

    The aim of this study was to determine the effect of music therapy on patients suffering dental anxiety. In addition, a second objective was to determine the correlation between salivary cortisol and other physiologic parameters. 34 patients were randomly assigned to the control group and the experimental group. For each patient was measured for salivary cortisol, stimulate salivary flow, blood pressure, heart rate, oxygen saturation and body temperature. Student t-test and Chi2 were applied to analyze significant differences between the studied variables before and after the unpleasant stimulation causes anxiety for dental treatment. Initially, both groups registered the same level of anxiety. In the second measurement, significant differences were registered in the salivary cortisol concentration, systolic and diastolic pressure, heart rate, body temperature and stimulated salivary flow for treated group with music therapy. Music therapy has a positive effect in control of dental anxiety. Copyright © 2015. Published by Elsevier Ltd.

  14. Doppler aortic flow velocity measurement in healthy children.

    PubMed Central

    Sohn, S.; Kim, H. S.

    2001-01-01

    To determine normal values for Doppler parameters of left ventricular function, ascending aortic blood flow velocity was measured by pulsed wave Doppler echocardiography in 63 healthy children with body surface area (BSA) < 1 m(2) (age < 10 yr). Peak velocity was independent of sex, but increased with body size. Mean acceleration was related to peak velocity (r = 0.75, p < 0.0001). Both stroke distance and ejection time had strong negative correlations with heart rate and positive correlations with BSA, suggesting that these parameters should be evaluated in relation to heart rate and body size. Mean intra- and interobserver variability for peak velocity, ejection time, stroke and minute distance ranged from 3 to 7%, whereas variability for acceleration time was 9 to 13%. These data may be used as reference values for the assessment of hemodynamic states in young children with cardiac disease. PMID:11306737

  15. Gestational diabetes alters the fetal heart rate variability during an oral glucose tolerance test: a fetal magnetocardiography study.

    PubMed

    Fehlert, E; Willmann, K; Fritsche, L; Linder, K; Mat-Husin, H; Schleger, F; Weiss, M; Kiefer-Schmidt, I; Brucker, S; Häring, H-U; Preissl, H; Fritsche, A

    2017-11-01

    Gestational diabetes mellitus (GDM) potentially harms the child before birth. We previously found GDM to be associated with developmental changes in the central nervous system. We now hypothesise that GDM may also impact on the fetal autonomic nervous system under metabolic stress like an oral glucose tolerance test (OGTT). We measured heart rate variability (HRV) of mothers and fetuses during a three-point OGTT using fetal magnetocardiography (fMCG). Measurements were performed in the fMEG Centre in Tübingen. After exclusion of 23 participants, 13 pregnant women with GDM and 36 pregnant women with normal glucose tolerance were examined. All women underwent the same examination setting with OGTT during which fMCG was recorded three times. Parameters of heart rate variability were measured. Compared with mothers with normal glucose regulation, mothers with GDM showed increased heart rate but no significant differences of maternal HRV. In contrast, HRV in fetuses of mothers with GDM differed from those in the metabolically healthy group regarding standard deviation normal to normal beat (SDNN) (P = 0.012), low-frequency band (P = 0.008) and high-frequency band (P = 0.031). These HRV parameters exhibit a decrease only in GDM fetuses during the second hour of the OGTT. These results show an altered response of the fetal autonomic nervous system to metabolic stress in GDM-complicated pregnancies. Hence, disturbances in maternal glucose metabolism might not only impact on the central nervous system of the fetus but may also affect the fetal autonomic nervous system. Metabolic stress reveals a different response of fetal autonomic nervous system in GDM-complicated pregnancies. © 2016 Royal College of Obstetricians and Gynaecologists.

  16. STUDIES IN FETAL BEHAVIOR: REVISITED, RENEWED, AND REIMAGINED.

    PubMed

    DiPietro, Janet A; Costigan, Kathleen A; Voegtline, Kristin M

    2015-09-01

    Among the earliest volumes of this monograph series was a report by Lester Sontag and colleagues, of the esteemed Fels Institute, on the heart rate of the human fetus as an expression of the developing nervous system. Here, some 75 years later, we commemorate this work and provide historical and contemporary context on knowledge regarding fetal development, as well as results from our own research. These are based on synchronized monitoring of maternal and fetal parameters assessed between 24 and 36 weeks gestation on 740 maternal-fetal pairs compiled from eight separate longitudinal studies, which commenced in the early 1990s. Data include maternal heart rate, respiratory sinus arrhythmia, and electrodrmal activity and fetal heartrate, motor activity, and their integration. Hierarchical linear modeling of developmental trajectories reveals that the fetus develops in predictable ways consistent with advancing parasympathetic regulation. Findings also include:within-fetus stability (i.e., preservation of rank ordering over time) for heart rate, motor, and coupling measures; a transitional period of decelerating development near 30 weeks gestation; sex differences in fetal heart rate measures but not in most fetal motor activity measures; modest correspondence in fetal neurodevelopment among siblings as compared to unrelated fetuses; and deviations from normative fetal development in fetuses affected by intrauterine growth restriction and other conditions. Maternal parameters also change during this period of gestation and there is evidence that fetal sex and individual variation in fetal neurobehavior influence maternal physio-logical processes and the local intrauterine context. Results are discussed within the framework of neuromaturation, the emergence of individual differences, and the bidirectional nature of the maternal-fetal relationship.We pose a number of open questions for future research. Although the human fetus remains just out of reach, new technologies portend an era of accelerated discovery of the earliest period of development

  17. Evaluation of CO2 anaesthesia applied by a commercial device for the castration of male suckling piglets under field conditions.

    PubMed

    Langhoff, Rebecca; Auer, Ulrike; Maneng, Julia; Hochgerner, Agnes; Ritzmann, Mathias

    2016-01-01

    The aim of this study was to describe clinical and behavioural parameters of piglets castrated with the use of CO2 anaesthesia by using the commercial available device MS Pigsleeper. 80 male piglets with three to six days of age were allocated to four groups, and were castrated or left uncastrated either after receiving 70% CO2/30% O02, or without anaesthesia. Defensive movements and heart rates were measured during induction and castration phase. At castration phase the dewclaw reflex was tested and piglets were monitored for vocalisation. During recovery and the subsequent five minutes conspicuous behaviours were recorded. Intensity of defensive movements was significantly higher in groups with CO2 anaesthesia during induction phase. Defensive movements were significantly lower in groups with CO2, but also not fully absent, during castration phase. Surgical tolerance was only reached by 20% (4/20) of piglets castrated under anaesthesia. Heart rates were above physiological levels at the beginning of induction phase and dropped significantly thereafter. Dropping of heart rates was more pronounced in anaesthetised groups leading to significant differences compared to non-anaesthetised groups. A minimum heart rate of 20 beats per minute was measured. Conspicuous behaviours as spasms, gasping and licking were described for pigs after CO2 anaesthesia. Measured parameters implicated stress and discomfort during induction and recovery phase and severe cardiovascular depression during CO2 anaesthesia. Surgical tolerance was reached by only a small proportion of anaesthetised piglets. Therefore, welfare aspects were not met using CO2 anaesthesia for piglet castration in general and especially by applying the gas anaesthesia with the commercial device MS Pigsleeper.

  18. Oxytocin treatment does not change cardiovascular parameters, hematology and plasma electrolytes in parturient horse mares.

    PubMed

    Nagel, Christina; Trenk, Lisa; Wulf, Manuela; Ille, Natascha; Aurich, Jörg; Aurich, Christine

    2017-03-15

    In mares, foaling is associated with changes in hematology, plasma electrolytes, blood pressure and heart rate and it has been hypothesized that these are induced by oxytocin. To test this hypothesis, mares (n = 8-14/group) were treated with oxytocin (OT; 20 I.U.) or saline (CON) at 1 h (test A) and 12 h after foaling (test B) and during first postpartum diestrus (test C). Heart rate, heart rate variability (HRV), atrioventricular blocks, salivary cortisol concentration, blood pressure, plasma electrolytes and blood count were determined. Heart rate decreased from test A to C (P < 0.001) but at no time differed between groups. The HRV, blood pressure and occurrence of atrioventricular blocks did not change in response to oxytocin. Cortisol concentration decreased from test A to C (P < 0.001). Oxytocin induced a cortisol release in test B (time x treatment P < 0.001, time x test P < 0.001). Plasma sodium and chloride concentrations decreased from test A to C (P < 0.001) but did not differ between groups. In test A, potassium concentration increased in CON but not OT mares (time P < 0.01, time x test P < 0.01, time x treatment P < 0.05). Polymorphnuclear cell (PMN) numbers in blood decreased from test A to C (P < 0.001) while lymphocytes increased (P < 0.05). At no time PMN and lymphocytes differed between groups. Oxytocin treatment had no effect on skin temperature. In conclusion, except for a limited effect on cortisol release, oxytocin was without effect and the hypothesis of oxytocin-induced alterations in cardiac parameters, plasma electrolytes and hematology of foaling mares was not verified. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Localised photoplethysmography imaging for heart rate estimation of pre-term infants in the clinic

    NASA Astrophysics Data System (ADS)

    Chaichulee, Sitthichok; Villarroel, Mauricio; Jorge, João.; Arteta, Carlos; Green, Gabrielle; McCormick, Kenny; Zisserman, Andrew; Tarassenko, Lionel

    2018-02-01

    Non-contact vital-sign estimation allows the monitoring of physiological parameters (such as heart rate, respiratory rate, and peripheral oxygen saturation) without contact electrodes or sensors. Our recent work has demonstrated that a convolutional neural network (CNN) can be used to detect the presence of a patient and segment the patient's skin area for vital-sign estimation, thus enabling the automatic continuous monitoring of vital signs in a hospital environment. In a study approved by the local Research Ethical Committee, we made video recordings of pre-term infants nursed in a Neonatal Intensive Care Unit (NICU) at the John Radcliffe Hospital in Oxford, UK. We extended the CNN model to detect the head, torso and diaper of the infants. We extracted multiple photoplethysmographic imaging (PPGi) signals from each body part, analysed their signal quality, and compared them with the PPGi signal derived from the entire skin area. Our results demonstrated the benefits of estimating heart rate combined from multiple regions of interest using data fusion. In the test dataset, we achieved a mean absolute error of 2.4 beats per minute for 80% (31.1 hours) from a total recording time of 38.5 hours for which both reference heart rate and video data were valid.

  20. Heart rate calculation from ensemble brain wave using wavelet and Teager-Kaiser energy operator.

    PubMed

    Srinivasan, Jayaraman; Adithya, V

    2015-01-01

    Electroencephalogram (EEG) signal artifacts are caused by various factors, such as, Electro-oculogram (EOG), Electromyogram (EMG), Electrocardiogram (ECG), movement artifact and line interference. The relatively high electrical energy cardiac activity causes EEG artifacts. In EEG signal processing the general approach is to remove the ECG signal. In this paper, we introduce an automated method to extract the ECG signal from EEG using wavelet and Teager-Kaiser energy operator for R-peak enhancement and detection. From the detected R-peaks the heart rate (HR) is calculated for clinical diagnosis. To check the efficiency of our method, we compare the HR calculated from ECG signal recorded in synchronous with EEG. The proposed method yields a mean error of 1.4% for the heart rate and 1.7% for mean R-R interval. The result illustrates that, proposed method can be used for ECG extraction from single channel EEG and used in clinical diagnosis like estimation for stress analysis, fatigue, and sleep stages classification studies as a multi-model system. In addition, this method eliminates the dependence of additional synchronous ECG in extraction of ECG from EEG signal process.

  1. Fetal heart rate and fetal heart rate variability in Lipizzaner broodmares.

    PubMed

    Baska-Vincze, Boglárka; Baska, Ferenc; Szenci, Ottó

    2015-03-01

    Monitoring fetal heart rate (FHR) and fetal heart rate variability (FHRV) helps to understand and evaluate normal and pathological conditions in the foal. The aim of this study was to establish normal heart rate reference values for the ongoing equine pregnancy and to perform a heart rate variability (HRV) time-domain analysis in Lipizzaner mares. Seventeen middle- and late-term (days 121-333) pregnant Lipizzaner mares were examined using fetomaternal electrocardiography (ECG). The mean FHR (P = 0.004) and the standard deviation of FHR (P = 0.012) significantly decreased during the pregnancy. FHR ± SD values decreased from 115 ± 35 to 79 ± 9 bpm between months 5 and 11. Our data showed that HRV in the foal decreased as the pregnancy progressed, which is in contrast with the findings of earlier equine studies. The standard deviation of normal-normal intervals (SDNN) was higher (70 ± 25 to 166 ± 108 msec) than described previously. The root mean square of successive differences (RMSSD) decreased from 105 ± 69 to 77 ± 37 msec between the 5th and 11th month of gestation. Using telemetric ECG equipment, we could detect equine fetal heartbeat on day 121 for the first time. In addition, the large differences observed in the HR values of four mare-fetus pairs in four consecutive months support the assumption that there might be 'high-HR' and 'low-HR' fetuses in horses. It can be concluded that the analysis of FHR and FHRV is a promising tool for the assessment of fetal well-being but the applicability of these parameters in the clinical setting and in studs requires further investigation.

  2. Acute effects of a sarin-like organophosphorus agent, bis(isopropyl methyl)phosphonate, on cardiovascular parameters in anaesthetized, artificially ventilated rats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Watanabe, Yoshimasa; Itoh, Takeo, E-mail: titoh@med.nagoya-cu.ac.jp; Shiraishi, Hiroaki

    The organophosphorus compound sarin irreversibly inhibits acetylcholinesterase. We examined the acute cardiovascular effects of a sarin-like organophosphorus agent, bis(isopropyl methyl)phosphonate (BIMP), in anaesthetized, artificially ventilated rats. Intravenous administration of BIMP (0.8 mg/kg; the LD50 value) induced a long-lasting increase in blood pressure and tended to increase heart rate. In rats pretreated with the non-selective muscarinic-receptor antagonist atropine, BIMP significantly increased both heart rate and blood pressure. In atropine-treated rats, hexamethonium (antagonist of ganglionic nicotinic receptors) greatly attenuated the BIMP-induced increase in blood pressure without changing the BIMP-induced increase in heart rate. In rats treated with atropine plus hexamethonium, intravenous phentolaminemore » (non-selective α-adrenergic receptor antagonist) plus propranolol (non-selective β-adrenergic receptor antagonist) completely blocked the BIMP-induced increases in blood pressure and heart rate. In atropine-treated rats, the reversible acetylcholinesterase inhibitor neostigmine (1 mg/kg) induced a transient increase in blood pressure, but had no effect on heart rate. These results suggest that in anaesthetized rats, BIMP induces powerful stimulation of sympathetic as well as parasympathetic nerves and thereby modulates heart rate and blood pressure. They may also indicate that an action independent of acetylcholinesterase inhibition contributes to the acute cardiovascular responses induced by BIMP. - Highlights: • A sarin-like agent BIMP markedly increased blood pressure in anaesthetized rats. • Muscarinic receptor blockade enhanced the BIMP-induced increase in blood pressure. • Ganglionic nicotinic receptor blockade attenuated the BIMP-induced response. • Blockade of α- as well as β-receptors attenuated the BIMP-induced response.« less

  3. The integration of depressive behaviors and cardiac dysfunction during an operational measure of depression: investigating the role of negative social experiences in an animal model.

    PubMed

    Grippo, Angela J; Moffitt, Julia A; Sgoifo, Andrea; Jepson, Amanda J; Bates, Suzanne L; Chandler, Danielle L; McNeal, Neal; Preihs, Kristin

    2012-01-01

    There is a bidirectional association between depression and cardiovascular disease. The neurobiological mechanisms underlying this association may involve an inability to cope with disrupted social bonds. This study investigated in an animal model the integration of depressive behaviors and cardiac dysfunction after a disrupted social bond and during an operational measure of depression, relative to the protective effects of intact social bonds. Depressive behaviors in the forced swim test and continuous electrocardiographic parameters were measured in 14 adult, female socially monogamous prairie voles (rodents), after 4 weeks of social pairing or isolation. After social isolation, animals exhibited (all values are mean ± standard error of the mean; isolated versus paired, respectively) increased heart rate (416 ± 14 versus 370 ± 14 bpm, p < .05) and reduced heart rate variability (3.3 ± 0.2 versus 3.9 ± 0.2 ln(ms(2))). During the forced swim test, isolated animals exhibited greater helpless behavior (immobility = 106 ± 11 versus 63 ± 11 seconds, p < .05), increased heart rate (530 ± 22 versus 447 ± 15 bpm, p < .05), reduced heart rate variability (1.8 ± 0.4 versus 2.7 ± 0.2 ln(ms(2)), p < .05), and increased arrhythmias (arrhythmic burden score = 181 ± 46 versus 28 ± 12, p < .05). The display of depressive behaviors during an operational measure of depression is coupled with increased heart rate, reduced heart rate variability, and increased arrhythmias, indicative of dysfunctional behavioral and physiological stress coping abilities as a function of social isolation. In contrast, social pairing with a sibling is behaviorally protective and cardioprotective. The present results can provide insight into a possible social mechanism underlying the association between depression and cardiovascular disease in humans.

  4. Radiation dose to patients and image quality evaluation from coronary 256-slice computed tomographic angiography

    NASA Astrophysics Data System (ADS)

    Chen, Liang-Kuang; Wu, Tung-Hsin; Yang, Ching-Ching; Tsai, Chia-Jung; Lee, Jason J. S.

    2010-07-01

    The aim of this study is to assess radiation dose and the corresponding image quality from suggested CT protocols which depends on different mean heart rate and high heart rate variability by using 256-slice CT. Fifty consecutive patients referred for a cardiac CT examination were included in this study. All coronary computed tomographic angiography (CCTA) examinations were performed on a 256-slice CT scanner with one of five different protocols: retrospective ECG-gating (RGH) with full dose exposure in all R-R intervals (protocol A), RGH of 30-80% pulsing window with tube current modulation (B), RGH of 78±5% pulsing window with tube current modulation (C), prospective ECG-triggering (PGT) of 78% R-R interval with 5% padding window (D) and PGT of 78% R-R interval without padding window (E). Radiation dose parameters and image quality scoring were determined and compared. In this study, no significant differences were found in comparison on image quality of the five different protocols. Protocol A obtained the highest radiation dose comparing with those of protocols B, C, D and E by a factor of 1.6, 2.4, 2.5 and 4.3, respectively ( p<0.001), which were ranged between 2.7 and 11.8 mSv. The PGT could significantly reduce radiation dose delivered to patients, as compared to the RGH. However, the use of PGT has limitations and is only good in assessing cases with lower mean heart rate and stable heart rate variability. With higher mean heart rate and high heart rate variability circumstances, the RGH within 30-80% of R-R interval pulsing window is suggested as a feasible technique for assessing diagnostic performance.

  5. Quadratic Frequency Modulation Signals Parameter Estimation Based on Two-Dimensional Product Modified Parameterized Chirp Rate-Quadratic Chirp Rate Distribution.

    PubMed

    Qu, Zhiyu; Qu, Fuxin; Hou, Changbo; Jing, Fulong

    2018-05-19

    In an inverse synthetic aperture radar (ISAR) imaging system for targets with complex motion, the azimuth echo signals of the target are always modeled as multicomponent quadratic frequency modulation (QFM) signals. The chirp rate (CR) and quadratic chirp rate (QCR) estimation of QFM signals is very important to solve the ISAR image defocus problem. For multicomponent QFM (multi-QFM) signals, the conventional QR and QCR estimation algorithms suffer from the cross-term and poor anti-noise ability. This paper proposes a novel estimation algorithm called a two-dimensional product modified parameterized chirp rate-quadratic chirp rate distribution (2D-PMPCRD) for QFM signals parameter estimation. The 2D-PMPCRD employs a multi-scale parametric symmetric self-correlation function and modified nonuniform fast Fourier transform-Fast Fourier transform to transform the signals into the chirp rate-quadratic chirp rate (CR-QCR) domains. It can greatly suppress the cross-terms while strengthening the auto-terms by multiplying different CR-QCR domains with different scale factors. Compared with high order ambiguity function-integrated cubic phase function and modified Lv's distribution, the simulation results verify that the 2D-PMPCRD acquires higher anti-noise performance and obtains better cross-terms suppression performance for multi-QFM signals with reasonable computation cost.

  6. A dose-response study of dexmedetomidine administered as the primary sedative in infants following open heart surgery.

    PubMed

    Su, Felice; Nicolson, Susan C; Zuppa, Athena F

    2013-06-01

    To evaluate the dose-response relationship of dexmedetomidine in infants with congenital heart disease postoperative from open heart surgery. Prospective open-label dose-escalation pharmacokinetic-pharmacodynamic study. Tertiary pediatric cardiac ICU. Thirty-six evaluable infants, 1-24 months old, postoperative from open heart surgery requiring mechanical ventilation. Cohorts of 12 infants were enrolled sequentially to one of the three IV loading doses of dexmedetomidine (0.35, 0.7, and 1 mcg/kg) over 10 minutes followed by respective continuous infusions (0.25, 0.5, and 0.75 mcg/kg/hr) for up to 24 hours. Dexmedetomidine plasma concentrations were obtained at timed intervals during and following discontinuation of infusion. Pharmacodynamic variables evaluated included sedation scores, supplemental sedation and analgesia medication administration, time to tracheal extubation, respiratory function, and hemodynamic parameters. Infants achieved a deeper sedation measured by the University of Michigan Sedation Scale score (2.6 vs 1) despite requiring minimal supplemental sedation (0 unit doses/hr) and fewer analgesic medications (0.07 vs 0.15 unit doses/hr) while receiving dexmedetomidine compared with the 12-hour follow-up period. Thirty-one patients were successfully extubated while receiving the dexmedetomidine infusion. Only one patient remained intubated due to oversedation during the infusion. While receiving dexmedetomidine, there was a decrease in heart rate compared with baseline, 132 versus 161 bpm, but there was an increase in heart rate compared with postinfusion values, 132 versus 128 bpm. There was no statistically or clinically significant change in mean arterial blood pressure. Dexmedetomidine administration in infants following open heart surgery can provide improved sedation with reduction in supplemental medication requirements, leading to successful extubation while receiving a continuous infusion. The postoperative hemodynamic changes that occur in infants postoperative from open heart surgery are multifactorial. Although dexmedetomidine may play a role in decreasing heart rate immediately postoperative, the changes were not clinically significant and did not fall below postinfusion heart rates.

  7. Heart rate turbulence in healthy dogs and dogs with dilated cardiomyopathy.

    PubMed

    Noszczyk-Nowak, A

    2012-01-01

    Heart rate turbulence (HRT) is modulated by the baroreceptor reflex and it was suggested that it could be used as a measure of autonomic dysfunction. Impaired HRT is of a significant prognostic value in humans after myocardial infarction, suffering from dilated cardiomyopathy and patients with heart failure. So far no studies were performed assessing the importance of HRT in dogs. The aim of this study was to prospectively evaluate the HRT turbulence onset (TO) and the turbulence slope (TS) in healthy dogs and in dogs with DCM and to compare the HRT in dogs with DCM that died during the first 30 days of observation and dogs with DCM that survived the first 30 days after the HRT analysis. The current study was aimed at determining reference value of the TO and TS of HRT in healthy dogs (control group) and dogs with dilated cardiomyopathy (DCM group). The tests were carried out on 30 healthy dogs and 30 dogs with DCM composed of Boxers, Doberman pinschers and Great Danes, of different sexes and body weights from 22 to 72 kg, aged between 1.5 and 11.5 years, submitted to the 24-hour Holter monitoring. HRT parameters were calculated using an HolCard software algorithm. TO is a percentage difference between the heart rate immediately following ventricular premature complex (VPC) and the heart rate immediately preceding VPC. TS corresponds to the steepest slope of the linear regression line for each sequence of five consecutive normal intervals in the local tachogram. The average TO in healthy dogs was determined as -13.55 +/- 11.12%, TS was 21.33 +/- 9.66 ms/RR. TO in dogs with DCM was determined as - 2.61 +/- 2.1% and TS was 6.15 +/- 3.86 ms/RR. Parameters of HRT were statistically significantly decreased (p < 0.01) in dogs with DCM. HRT TO and TS were statistically significantly decreased in dogs with DCM. Dogs with DCM that survived more than 30 days of observation had HRT statistically significantly decreased in comparison to dogs with DCM that died after the 30'th day of observation. Decreased HRT parameters in dogs with DCM suggest an autonomic neuropathy which principally consists of the withdrawal of the cardiac parasympathetic tone. The more the autonomic neuropathy is advanced the faster the death of the dog with DCM might occur, with no correlation with the level of the heart failure.

  8. The Role of Heart-Rate Variability Parameters in Activity Recognition and Energy-Expenditure Estimation Using Wearable Sensors.

    PubMed

    Park, Heesu; Dong, Suh-Yeon; Lee, Miran; Youn, Inchan

    2017-07-24

    Human-activity recognition (HAR) and energy-expenditure (EE) estimation are major functions in the mobile healthcare system. Both functions have been investigated for a long time; however, several challenges remain unsolved, such as the confusion between activities and the recognition of energy-consuming activities involving little or no movement. To solve these problems, we propose a novel approach using an accelerometer and electrocardiogram (ECG). First, we collected a database of six activities (sitting, standing, walking, ascending, resting and running) of 13 voluntary participants. We compared the HAR performances of three models with respect to the input data type (with none, all, or some of the heart-rate variability (HRV) parameters). The best recognition performance was 96.35%, which was obtained with some selected HRV parameters. EE was also estimated for different choices of the input data type (with or without HRV parameters) and the model type (single and activity-specific). The best estimation performance was found in the case of the activity-specific model with HRV parameters. Our findings indicate that the use of human physiological data, obtained by wearable sensors, has a significant impact on both HAR and EE estimation, which are crucial functions in the mobile healthcare system.

  9. Sleep-disordered breathing and daytime cardiac conduction abnormalities on 12-lead electrocardiogram in community-dwelling older men

    PubMed Central

    Kwon, Younghoon; Picel, Katherine; Adabag, Selcuk; Vo, Tien; Taylor, Brent C.; Redline, Susan; Stone, Katie; Mehra, Reena; Ancoli-Israel, Sonia

    2016-01-01

    Purpose Nocturnal cardiac conduction abnormalities are commonly observed in patients with sleep-disordered breathing (SDB). However, few population-based studies have examined the association between SDB and daytime cardiac conduction abnormalities. Methods We examined a random sample of 471 community-dwelling men, aged ≥67 years, enrolled in the multi-center Outcomes of Sleep Disorders in Older Men (MrOS Sleep) study. SDB severity was categorized using percent of total sleep time with oxygen saturation <90 % (%TST < 90) and apnea hypopnea index (AHI). Cardiac conduction parameters were assessed by resting 12-lead electrocardiography (ECG). All analyses were adjusted for age, site, β-blocker use, coronary heart disease, calcium channel blocker use, and use of antiarrhythmic medications. Results Mean age was 77 ± 6 years, median %TST < 90 was 0.7 (IQR 0.00–3.40), and median AHI was 7.06 (IQR 2.55–15.32). Men with greater nocturnal hypoxemia (%TST < 90 ≥ 3.5 %) compared with those without hypoxemia (%TST < 90 < 1.0 %) had a lower odds of bradycardia (OR 0.55 [0.32–0.94]) and right bundle branch block (RBBB) (OR 0.24 [0.08–0.75]) but a higher odds of ventricular paced rhythm (OR 4.42 [1.29–15.19]). Heart rate (HR) increased in a graded manner with increasing %TST < 90 (p-trend 0.01) and increasing AHI (p-trend 0.006), but these gradients were small in absolute magnitude. There were no associations of SDB measures with other ECG conduction parameters. Conclusions Greater nocturnal hypoxemia in older men was associated with a lower prevalence of daytime sinus bradycardia and RBBB, a higher prevalence of ventricular paced rhythm, and higher resting HR. PMID:26971326

  10. Sleep-disordered breathing and daytime cardiac conduction abnormalities on 12-lead electrocardiogram in community-dwelling older men.

    PubMed

    Kwon, Younghoon; Picel, Katherine; Adabag, Selcuk; Vo, Tien; Taylor, Brent C; Redline, Susan; Stone, Katie; Mehra, Reena; Ancoli-Israel, Sonia; Ensrud, Kristine E

    2016-12-01

    Nocturnal cardiac conduction abnormalities are commonly observed in patients with sleep-disordered breathing (SDB). However, few population-based studies have examined the association between SDB and daytime cardiac conduction abnormalities. We examined a random sample of 471 community-dwelling men, aged ≥67 years, enrolled in the multi-center Outcomes of Sleep Disorders in Older Men (MrOS Sleep) study. SDB severity was categorized using percent of total sleep time with oxygen saturation <90 % (%TST < 90) and apnea hypopnea index (AHI). Cardiac conduction parameters were assessed by resting 12-lead electrocardiography (ECG). All analyses were adjusted for age, site, β-blocker use, coronary heart disease, calcium channel blocker use, and use of antiarrhythmic medications. Mean age was 77 ± 6 years, median %TST < 90 was 0.7 (IQR 0.00-3.40), and median AHI was 7.06 (IQR 2.55-15.32). Men with greater nocturnal hypoxemia (%TST < 90 ≥ 3.5 %) compared with those without hypoxemia (%TST < 90 < 1.0 %) had a lower odds of bradycardia (OR 0.55 [0.32-0.94]) and right bundle branch block (RBBB) (OR 0.24 [0.08-0.75]) but a higher odds of ventricular paced rhythm (OR 4.42 [1.29-15.19]). Heart rate (HR) increased in a graded manner with increasing %TST < 90 (p-trend 0.01) and increasing AHI (p-trend 0.006), but these gradients were small in absolute magnitude. There were no associations of SDB measures with other ECG conduction parameters. Greater nocturnal hypoxemia in older men was associated with a lower prevalence of daytime sinus bradycardia and RBBB, a higher prevalence of ventricular paced rhythm, and higher resting HR.

  11. Effect of cell phone exposure on physiologic and hematologic parameters of male medical students of Bijapur (Karnataka) with reference to serum lipid profile.

    PubMed

    Parkar, Matin A; Ahmed, Rishad; Abdullah, Bilal Bin; Patil, B S; Das, Kusal K

    2010-01-01

    The public awareness about cell phone safety increased greatly in the last few years as various reports of potential adverse health effects on humans exposed to radiations emitted from cellular phones were published. The aim of the study was to assess the effect of long term cell phone exposure on physiological and hematological parameters along with its impact on serum lipid profiles and a single call effect on heart rate, blood pressure and SpO2(%) of healthy male medical students. The students were divided into two groups, group I (n=22, age 20.63 +/- 1.17 yrs) comprising first year medical students who were never exposed to cell phones at the time of this study and group II (n=35, age 22.00 +/- 1.56 yrs) consists of final year (fourth year) male medical students who were using cell phone for more than four years before this study. The results showed no significant differences the groups in basal heart rate, systolic blood pressure, SpO2(%), or various hematologic parameters. Acute exposure (single call of cell phone with 900 MHz for 1 minute) in both groups showed a significant increase in peak heart rate in group II as compared with group I and a significant decrease in peak SpO2 (%) in group I as compared with group II. Serum total cholesterol, VLDL-cholesterol, and triglycerides concentration were significantly higher in group II (long term cell phone exposed) than in group I, suggesting a mild alteration of lipid profile among group II subjects.

  12. Voice stress analysis

    NASA Technical Reports Server (NTRS)

    Brenner, Malcolm; Shipp, Thomas

    1988-01-01

    In a study of the validity of eight candidate voice measures (fundamental frequency, amplitude, speech rate, frequency jitter, amplitude shimmer, Psychological Stress Evaluator scores, energy distribution, and the derived measure of the above measures) for determining psychological stress, 17 males age 21 to 35 were subjected to a tracking task on a microcomputer CRT while parameters of vocal production as well as heart rate were measured. Findings confirm those of earlier studies that increases in fundamental frequency, amplitude, and speech rate are found in speakers involved in extreme levels of stress. In addition, it was found that the same changes appear to occur in a regular fashion within a more subtle level of stress that may be characteristic, for example, of routine flying situations. None of the individual speech measures performed as robustly as did heart rate.

  13. Feasibility investigations on multi-cutter milling process: A novel fabrication method for microreactors with multiple microchannels

    NASA Astrophysics Data System (ADS)

    Pan, Minqiang; Zeng, Dehuai; Tang, Yong

    A novel multi-cutter milling process for multiple parallel microchannels with manifolds is proposed to address the challenge of mass manufacture as required for cost-effective commercial applications. Several slotting cutters are stacked together to form a composite tool for machining microchannels simultaneously. The feasibility of this new fabrication process is experimentally investigated under different machining conditions and reaction characteristics of methanol steam reforming for hydrogen production. The influences of cutting parameters and the composite tool on the microchannel qualities and burr formation are analyzed. Experimental results indicate that larger cutting speed, smaller feed rate and cutting depth are in favor of obtaining relatively good microchannel qualities and small burrs. Of all the cutting parameters considered in these experiments, 94.2 m min -1 cutting speed, 23.5 mm min -1 feed rate and 0.5 mm cutting depth are found to be the optimum value. According to the comparisons of experimental results of multi-cutter milling process and estimated one of other alternative methods, it is found that multi-cutter milling process shows much shorter machining time and higher work removal rate than that of other alternative methods. Reaction characteristics of methanol steam reforming in microchannels also indicate that multi-cutter milling process is probably suitable for a commercial application.

  14. Peri-ictal ECG changes in childhood epilepsy: implications for detection systems.

    PubMed

    Jansen, Katrien; Varon, Carolina; Van Huffel, Sabine; Lagae, Lieven

    2013-10-01

    Early detection of seizures could reduce associated morbidity and mortality and improve the quality of life of patients with epilepsy. In this study, the aim was to investigate whether ictal tachycardia is present in focal and generalized epileptic seizures in children. We sought to predict in which type of seizures tachycardia can be identified before actual seizure onset. Electrocardiogram segments in 80 seizures were analyzed in time and frequency domains before and after the onset of epileptic seizures on EEG. These ECG parameters were analyzed to find the most informative ones that can be used for seizure detection. The algorithm of Leutmezer et al. was used to find the temporal relationship between the change in heart rate and seizure onset. In the time domain, the mean RR shows a significant difference before compared to after onset of the seizure in focal seizures. This can be observed in temporal lobe seizures as well as frontal lobe seizures. Calculation of mean RR interval has a high specificity for detection of ictal heart rate changes. Preictal heart rate changes are observed in 70% of the partial seizures. Ictal heart rate changes are present only in partial seizures in this childhood epilepsy study. The changes can be observed in temporal lobe seizures as well as in frontal lobe seizures. Heart rate changes precede seizure onset in 70% of the focal seizures, making seizure detection and closed-loop systems a possible therapeutic alternative in the population of children with refractory epilepsy. © 2013.

  15. Sleep-mediated heart rate variability after bilateral carotid body tumor resection.

    PubMed

    Niemeijer, Nicolasine D; Corssmit, Eleonora P M; Reijntjes, Robert H A M; Lammers, Gert Jan; van Dijk, J Gert; Thijs, Roland D

    2015-04-01

    The carotid bodies are thought to play an important role in sleep-dependent autonomic changes. Patients who underwent resection of bilateral carotid body tumors have chronically attenuated baroreflex sensitivity. These subjects provide a unique opportunity to investigate the role of the baroreflex during sleep. One-night ambulatory polysomnography (PSG) recording. Participants' homes. Nine patients with bilateral carotid body tumor resection (bCBR) (four women, mean age 50.4 ± 7.2 years) and nine controls matched for age, gender, and body mass index. N/A. Sleep parameters were obtained from PSG. Heart rate (HR) and its variability were calculated using 30-s epochs. In bCBR patients, HR was slightly but not significantly increased during wake and all sleep stages. The effect of sleep on HR was similar for patients and controls. Low frequency (LF) power of the heart rate variability spectrum was significantly lower in bCBR patients in active wakefulness, sleep stage 1 and REM sleep. No differences were found between patients and controls for high frequency (HF) power and the LF/HF ratio. Bilateral carotid body tumor resection (bCBR) is associated with decreased low frequency power during sleep, suggesting impaired baroreflex function. Despite this, sleep-related heart rate changes were similar between bCBR patients and controls. These findings suggest that the effects of sleep on heart rate are predominantly generated through central, non-baroreflex mediated pathways. © 2015 Associated Professional Sleep Societies, LLC.

  16. Anxiety sensitivity predicts increased perceived exertion during a 1-mile walk test among treatment-seeking smokers.

    PubMed

    Farris, Samantha G; Uebelacker, Lisa A; Brown, Richard A; Price, Lawrence H; Desaulniers, Julie; Abrantes, Ana M

    2017-12-01

    Smoking increases risk of early morbidity and mortality, and risk is compounded by physical inactivity. Anxiety sensitivity (fear of anxiety-relevant somatic sensations) is a cognitive factor that may amplify the subjective experience of exertion (effort) during exercise, subsequently resulting in lower engagement in physical activity. We examined the effect of anxiety sensitivity on ratings of perceived exertion (RPE) and physiological arousal (heart rate) during a bout of exercise among low-active treatment-seeking smokers. Adult daily smokers (n = 157; M age  = 44.9, SD = 11.13; 69.4% female) completed the Rockport 1.0 mile submaximal treadmill walk test. RPE and heart rate were assessed during the walk test. Multi-level modeling was used to examine the interactive effect of anxiety sensitivity × time on RPE and on heart rate at five time points during the walk test. There were significant linear and cubic time × anxiety sensitivity effects for RPE. High anxiety sensitivity was associated with greater initial increases in RPE during the walk test, with stabilized ratings towards the last 5 min, whereas low anxiety sensitivity was associated with lower initial increase in RPE which stabilized more quickly. The linear time × anxiety sensitivity effect for heart rate was not significant. Anxiety sensitivity is associated with increasing RPE during moderate-intensity exercise. Persistently rising RPE observed for smokers with high anxiety sensitivity may contribute to the negative experience of exercise, resulting in early termination of bouts of prolonged activity and/or decreased likelihood of future engagement in physical activity.

  17. Short-term heart rate variability (HRV) in healthy dogs.

    PubMed

    Bogucki, Sz; Noszczyk-Nowak, A

    2015-01-01

    Heart rate variability (HRV) is a well established mortality risk factor in both healthy dogs and those with heart failure. While the standards for short-term HRV analysis have been developed in humans, only reference values for HRV parameters determined from 24-hour ECG have been proposed in dogs. The aim of this study was to develop the reference values for short-term HRV parameters in a group of 50 healthy dogs of various breeds (age 4.86 ± 2.74 years, body weight 12.2 ± 3.88 kg). The ECG was recorded continuously for at least 180 min in a dark and quiet room. All electrocardiograms were inspected automatically and manually to eliminate atrial or ventricular premature complexes. Signals were transformed into a spectrum using the fast Fourier transform. The HRV parameters were measured at fixed times from 60-min ECG segments. The following time-domain parameters (ms) were analyzed: mean NN, SDNN, SDANN, SDNN index, rMSSD and pNN50. Moreover, frequency-domain parameters (Hz) were determined, including very low frequency (VLF), low frequency (LF) and high frequency (HF) components, total power (TP) and the LF/HF ratio. The results (means ± SD) were as follows: mean NN = 677.68 ± 126.89; SDNN = 208.86 ± 77.1; SDANN = 70.75 ± 30.9; SDNN index = 190.75 ± 76.12; rMSSD = 259 ± 120.17, pNN50 = 71.84 ± 13.96; VLF = 984.96 ± 327.7; LF = 1501.24 ± 736.32; HF = 5845.45 ± 2914.20; TP = 11065.31 ± 3866.87; LF/HF = 0.28 ± 0.11.

  18. The development of selected cardiovascular parameters in patients with type 2 diabetes mellitus during a spa treatment.

    PubMed

    Fialová, E; Kittnar, O

    2015-01-01

    Diabetes mellitus is not just a simple metabolic disorder, however, it is considered to be a cardiovascular disease of a metabolic origin. This is apparent especially when speaking about type 2 diabetes (DM II). The objective of our study was to determine whether a comprehensive spa treatment (procedures and drinking cure) may affect the level of the sympathetic tone of patients suffering from DM II. As an indicator of the sympathetic tone, selected electrocardiographic parameters derived from the heart rate variability and microwave alternans were chosen. There were 96 patients enrolled in our study: 38 patients with poorly controlled DM II and two control groups: 9 patients with compensated DM II and 49 patients, average age without diabetes or other disorders of the glucose metabolism. All received an identical spa treatment and continued their medical therapy. The electrophysiological examination of patients was performed before and after a three-week spa treatment using the KARDiVAR system. Parameters derived from the analysis of heart rate variability (HRV), microvolt T-wave alternans, and microvolt R-wave alternans were analyzed in order to evaluate the tones of the autonomic nervous system (ANS). The control group showed a slight increase of parameter the index of activity of regulatory systems (IRSA) (4.4+/-1.3 vs. 3.8+/-1.4; p=0.006) after the spa treatment, while increased heart rate (80.9+/-11.0 vs. 74.6+/-9.6; p=0.028), reduced index of centralization (IC) (1.3+/-0.6 vs. 2.9+/-1.4; p=0.027) and reduced index of myocardium (IM) (9.9+/-7.4 vs. 18.0+/-6.3; p=0.041) were found in patients with a compensated DM II. Patients with a poorly compensated DM II showed a decreased IM (10.9+/-8.6 vs. 16.9+/-5.2; p=0.001) and also a reduced IRSA (4.1+/-3.5 vs. 6.3+/-1.9; p=0.001). The results proved favorable changes in ANS cardiovascular control of patients with DM II after a spa treatment, especially in terms of reducing the sympathoadrenal system activity (decreased IRSA), improving electrical stability of the myocardium and increasing centrally controlled heart rate variability without overloading the cardiovascular system (drop of IM).

  19. Multicentre clinical trial experience with the HeartMate 3 left ventricular assist device: 30-day outcomes.

    PubMed

    Zimpfer, Daniel; Netuka, Ivan; Schmitto, Jan D; Pya, Yuriy; Garbade, Jens; Morshuis, Michiel; Beyersdorf, Friedhelm; Marasco, Silvana; Rao, Vivek; Damme, Laura; Sood, Poornima; Krabatsch, Thomas

    2016-09-01

    The objective of this study was to describe the operative experience and 30-day outcomes of patients implanted with the HeartMate 3 Left Ventricular Assist System (LVAS) during the Conformité Européenne (CE) Mark clinical trial. Adult patients met inclusion and exclusion criteria defining advanced-stage heart failure and included the indications of bridge to transplant and destination therapy. Operative parameters, outcomes, adverse events, physical status and quality-of-life parameters were assessed in the first 30 days after LVAS implant. Fifty patients were implanted with the HeartMate 3 at 10 centres in 6 countries. The 30-day survival rate was 98%. The median operative and cardiopulmonary bypass times were 200 (range: 95-585) min and 84 (range: 47-250) min, respectively. Patients required transfusion with packed red blood cells (3.6 ± 2.3 units), fresh frozen plasma (6.5 ± 5 units) and platelets (2 ± 1 units). Six patients (12%) required reoperation for postoperative bleeding and 10 patients (20%) did not require blood transfusion. The median intensive care time was 6 days (range: 1-112 days) and the total hospital stay was 28 days (range: 14-116 days). The most common adverse events were bleeding (15, 30%), arrhythmia (14, 28%) and infection (10, 20%). There were 2 (4%) strokes. The 30-day outcomes following implantation of the HeartMate 3 demonstrates excellent survival with low adverse event rates. The LVAD performed as intended with no haemolysis or device failure. NCT02170363. HeartMate 3™ CE Mark Clinical Investigation Plan (HM3 CE Mark). © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  20. Comparison of data mining techniques applied to fetal heart rate parameters for the early identification of IUGR fetuses.

    PubMed

    Magenes, G; Bellazzi, R; Malovini, A; Signorini, M G

    2016-08-01

    The onset of fetal pathologies can be screened during pregnancy by means of Fetal Heart Rate (FHR) monitoring and analysis. Noticeable advances in understanding FHR variations were obtained in the last twenty years, thanks to the introduction of quantitative indices extracted from the FHR signal. This study searches for discriminating Normal and Intra Uterine Growth Restricted (IUGR) fetuses by applying data mining techniques to FHR parameters, obtained from recordings in a population of 122 fetuses (61 healthy and 61 IUGRs), through standard CTG non-stress test. We computed N=12 indices (N=4 related to time domain FHR analysis, N=4 to frequency domain and N=4 to non-linear analysis) and normalized them with respect to the gestational week. We compared, through a 10-fold crossvalidation procedure, 15 data mining techniques in order to select the more reliable approach for identifying IUGR fetuses. The results of this comparison highlight that two techniques (Random Forest and Logistic Regression) show the best classification accuracy and that both outperform the best single parameter in terms of mean AUROC on the test sets.

  1. Confocal Microscopy-Based Estimation of Parameters for Computational Modeling of Electrical Conduction in the Normal and Infarcted Heart.

    PubMed

    Greiner, Joachim; Sankarankutty, Aparna C; Seemann, Gunnar; Seidel, Thomas; Sachse, Frank B

    2018-01-01

    Computational modeling is an important tool to advance our knowledge on cardiac diseases and their underlying mechanisms. Computational models of conduction in cardiac tissues require identification of parameters. Our knowledge on these parameters is limited, especially for diseased tissues. Here, we assessed and quantified parameters for computational modeling of conduction in cardiac tissues. We used a rabbit model of myocardial infarction (MI) and an imaging-based approach to derive the parameters. Left ventricular tissue samples were obtained from fixed control hearts (animals: 5) and infarcted hearts (animals: 6) within 200 μm (region 1), 250-750 μm (region 2) and 1,000-1,250 μm (region 3) of the MI border. We assessed extracellular space, fibroblasts, smooth muscle cells, nuclei and gap junctions by a multi-label staining protocol. With confocal microscopy we acquired three-dimensional (3D) image stacks with a voxel size of 200 × 200 × 200 nm. Image segmentation yielded 3D reconstructions of tissue microstructure, which were used to numerically derive extracellular conductivity tensors. Volume fractions of myocyte, extracellular, interlaminar cleft, vessel and fibroblast domains in control were (in %) 65.03 ± 3.60, 24.68 ± 3.05, 3.95 ± 4.84, 7.71 ± 2.15, and 2.48 ± 1.11, respectively. Volume fractions in regions 1 and 2 were different for myocyte, myofibroblast, vessel, and extracellular domains. Fibrosis, defined as increase in fibrotic tissue constituents, was (in %) 21.21 ± 1.73, 16.90 ± 9.86, and 3.58 ± 8.64 in MI regions 1, 2, and 3, respectively. For control tissues, image-based computation of longitudinal, transverse and normal extracellular conductivity yielded (in S/m) 0.36 ± 0.11, 0.17 ± 0.07, and 0.1 ± 0.06, respectively. Conductivities were markedly increased in regions 1 ( + 75 , + 171, and + 100%), 2 ( + 53 , + 165, and + 80%), and 3 ( + 42 , + 141, and + 60%) . Volume fractions of the extracellular space including interlaminar clefts strongly correlated with conductivities in control and MI hearts. Our study provides novel quantitative data for computational modeling of conduction in normal and MI hearts. Notably, our study introduces comprehensive statistical information on tissue composition and extracellular conductivities on a microscopic scale in the MI border zone. We suggest that the presented data fill a significant gap in modeling parameters and extend our foundation for computational modeling of cardiac conduction.

  2. Echocardiographic strain and strain-rate imaging: a new tool to study regional myocardial function.

    PubMed

    D'hooge, Jan; Bijnens, Bart; Thoen, Jan; Van de Werf, Frans; Sutherland, George R; Suetens, Paul

    2002-09-01

    Ultrasonic imaging is the noninvasive clinical imaging modality of choice for diagnosing heart disease. At present, two-dimensional ultrasonic grayscale images provide a relatively cheap, fast, bedside method to study the morphology of the heart. Several methods have been proposed to assess myocardial function. These have been based on either grayscale or motion (velocity) information measured in real-time. However, the quantitative assessment of regional myocardial function remains an important goal in clinical cardiology. To do this, ultrasonic strain and strain-rate imaging have been introduced. In the clinical setting, these techniques currently only allow one component of the true three-dimensional deformation to be measured. Clinical, multidimensional strain (rate) information can currently thus only be obtained by combining data acquired using different transducer positions. Nevertheless, given the appropriate postprocessing, the clinical value of these techniques has already been shown. Moreover, multidimensional strain and strain-rate estimation of the heart in vivo by means of a single ultrasound acquisition has been shown to be feasible. In this paper, the new techniques of ultrasonic strain rate and strain imaging of the heart are reviewed in terms of definitions, data acquisition, strain-rate estimation, postprocessing, and parameter extraction. Their clinical validation and relevance will be discussed using clinical examples on relevant cardiac pathology. Based on these examples, suggestions are made for future developments of these techniques.

  3. Atherosclerotic Cardiovascular Disease and Heart Failure in Type 2 Diabetes – Mechanisms, Management, and Clinical Considerations

    PubMed Central

    Low Wang, Cecilia C.; Hess, Connie N.; Hiatt, William R.; Goldfine, Allison B.

    2016-01-01

    Cardiovascular disease remains the principal cause of death and disability among patients with diabetes mellitus. Diabetes exacerbates mechanisms underlying atherosclerosis and heart failure. Unfortunately, these mechanisms are not adequately modulated by therapeutic strategies focusing solely on optimal glycemic control with currently available drugs or approaches. In the setting of multi-factorial risk reduction with statins and other lipid lowering agents, anti-hypertensive therapies, and anti-hyperglycemic treatment strategies, cardiovascular complication rates are falling, yet remain higher for patients with diabetes than for those without. This review considers the mechanisms, history, controversies, new pharmacologic agents, and recent evidence for current guidelines for cardiovascular management in the patient with diabetes mellitus to support evidence-based care in the patient with diabetes and heart disease outside of the acute care setting. PMID:27297342

  4. Characterization of Cardiac Time Intervals in Healthy Bonnet Macaques (Macaca radiata) by Using an Electronic Stethoscope

    PubMed Central

    Kamran, Haroon; Salciccioli, Louis; Pushilin, Sergei; Kumar, Paraag; Carter, John; Kuo, John; Novotney, Carol; Lazar, Jason M

    2011-01-01

    Nonhuman primates are used frequently in cardiovascular research. Cardiac time intervals derived by phonocardiography have long been used to assess left ventricular function. Electronic stethoscopes are simple low-cost systems that display heart sound signals. We assessed the use of an electronic stethoscope to measure cardiac time intervals in 48 healthy bonnet macaques (age, 8 ± 5 y) based on recorded heart sounds. Technically adequate recordings were obtained from all animals and required 1.5 ± 1.3 min. The following cardiac time intervals were determined by simultaneously recording acoustic and single-lead electrocardiographic data: electromechanical activation time (QS1), electromechanical systole (QS2), the time interval between the first and second heart sounds (S1S2), and the time interval between the second and first sounds (S2S1). QS2 was correlated with heart rate, mean arterial pressure, diastolic blood pressure, and left ventricular ejection time determined by using echocardiography. S1S2 correlated with heart rate, mean arterial pressure, diastolic blood pressure, left ventricular ejection time, and age. S2S1 correlated with heart rate, mean arterial pressure, diastolic blood pressure, systolic blood pressure, and left ventricular ejection time. QS1 did not correlate with any anthropometric or echocardiographic parameter. The relation S1S2/S2S1 correlated with systolic blood pressure. On multivariate analyses, heart rate was the only independent predictor of QS2, S1S2, and S2S1. In conclusion, determination of cardiac time intervals is feasible and reproducible by using an electrical stethoscope in nonhuman primates. Heart rate is a major determinant of QS2, S1S2, and S2S1 but not QS1; regression equations for reference values for cardiac time intervals in bonnet macaques are provided. PMID:21439218

  5. Sildenafil improves heart rate variability in dogs with asymptomatic myxomatous mitral valve degeneration

    PubMed Central

    PIRINTR, Prapawadee; SAENGKLUB, Nakkawee; LIMPRASUTR, Vudhiporn; SAWANGKOON, Suwanakiet; KIJTAWORNRAT, Anusak

    2017-01-01

    Myxomatous mitral valve degeneration (MMVD) causes an imbalance of sympathovagal activity resulted in poor cardiac outcomes. Phosphodiesterase-5 inhibitors have been revealed cardioprotective effect in patients with heart diseases. This study aimed to 1) compare the heart rate variability (HRV) between asymptomatic MMVD and healthy dogs and 2) assess long-term effects of sildenafil and enalapril on time- and frequency-domains analyzes. Thirty-four dogs with MMVD stage B1 or B2 and thirteen healthy dogs were recruited into the study. MMVD dogs were divided into 3 subgroups: control (n=13), sildenafil (n=12) and enalapril (n=9). HRV was analyzed from 1-hr Holter recording at baseline (D0) in all dogs and at 30, 90 and 180 days after treatment. The results showed that MMVD dogs had significant higher heart rate (HR), systemic blood pressures, the ratio of low to high frequency (LF/HF) and had significant decreased standard deviation of all normal to normal RR intervals (SDNN) and the percentage of the number of normal-to-normal sinus RR intervals with differences >50 msec computed over the entire recording (pNN50) when compared with healthy dogs (P<0.05). Neither time nor frequency domain parameters were different among subgroups of MMVD dogs at D0. After treatment with sildenafil for 90 days, both time- and frequency-domain parameters were significantly increased when compared with control and enalapril groups. This study demonstrated that sildenafil improves HRV in asymptomatic MMVD dogs suggesting that sildenafil should be used in the MMVD dogs to restore the sympathovagal balance. PMID:28717064

  6. Cardiac and Vascular Function in Bedrested Volunteers: Effects of Artificial Gravity Training

    NASA Technical Reports Server (NTRS)

    Meng, M.; Platts, S.; Stenger, M.; Diedrich, A.; Schlegel, T.; Natapoff, A.; Knapp, C.; Evans, J.

    2007-01-01

    Cardiovascular effects of an artificial gravity (AG) countermeasure on deconditioned male volunteers were studied. In two groups of men we measured cardiovascular parameters at rest and in response to 30 minutes of 80 deg. head up tilt (HUT) before, at the end of, and four days following 21 days of 6 deg. head down bed rest (HDBR). One group (N=7) underwent no countermeasure while the other (N=8) received a daily, one hour, dose (2.5 gz at the foot, decreasing to 1.0 gz at the heart) of AG training on the Johnson Space Center short radius centrifuge. Cardiovascular parameters measured included heart rate, blood pressure, stroke volume, cardiac output, peripheral vascular resistance, plasma volume shifts, and vasoactive hormones. Untrained subjects exhibited shorter tilt survival (on average 8 minutes shorter) compared to trained subjects. By the end of bed rest, mean heart rate (MHR) was elevated in both groups (both supine and during tilt). In addition, treated subjects demonstrated lower, tilt-induced, increases in MHR four days following HDBR, indicating a more rapid return to pre bed rest conditions. Results from an index of autonomic balance (percentage of MHR spectral power in the respiratory frequency range) in control of heart rate are consistent with the interpretation that parasympathetic nervous system withdrawal was responsible for both tilt- and bed rest-induced increases in MHR. Our data support our pre-study hypothesis that AG treatment would lessen cardiovascular effects of deconditioning in bed rested men and suggest that AG should be further pursued as a space flight countermeasure.

  7. Near-infrared spectroscopy as a predictor of clinical deterioration: a case report of two infants with duct-dependent congenital heart disease.

    PubMed

    Mebius, Mirthe J; du Marchie Sarvaas, Gideon J; Wolthuis, Diana W; Bartelds, Beatrijs; Kneyber, Martin C J; Bos, Arend F; Kooi, Elisabeth M W

    2017-03-16

    Some infants with congenital heart disease are at risk of in-hospital cardiac arrest. To better foresee cardiac arrest in infants with congenital heart disease, it might be useful to continuously assess end-organ perfusion. Near-infrared spectroscopy is a non-invasive method to continuously assess multisite regional tissue oxygen saturation. We report on two infants with duct-dependent congenital heart disease who demonstrated a gradual change in cerebral and/or renal tissue oxygen saturation before cardiopulmonary resuscitation was required. In both cases, other clinical parameters such as heart rate, arterial oxygen saturation and blood pressure did not indicate that deterioration was imminent. These two cases demonstrate that near-infrared spectroscopy might contribute to detecting a deteriorating clinical condition and might therefore be helpful in averting cardiopulmonary collapse and need for resuscitation in infants with congenital heart disease.

  8. Effect of propranolol on heart rate variability in hyperthyroidism.

    PubMed

    Tankeu, Aurel T; Azabji-Kenfack, Marcel; Nganou, Chris-Nadège; Ngassam, Eliane; Kuate-Mfeukeu, Liliane; Mba, Camille; Dehayem, Mesmin Y; Mbanya, Jean-Claude; Sobngwi, Eugene

    2018-02-22

    We aimed to determine the effect of propanolol on heart rate variability (HRV) in hyperthyroidism before antithyroid treatment. This was a before and after study, on ten patients presenting overt hyperthyroidism naïve to treatment. In each patient, a resting electrocardiogram was done followed by estimation of cardiac autonomic dysfunction during five maneuvers (Ewing battery tests). Long term HRV measurement was done using 24 h ambulatory electrocardiographic recording. This automatically provided estimation of HRV using SDNN and RMSSD index, LF, HF, and HF/LF ratio. After baseline investigations, 40 mg of propanolol was given twice a day for 3 days and same parameters were measured after 72 h of treatment. Our patients were aged 40 ± 10 years. Propanolol significantly reduced RR and HR interval (669 ms vs 763 ms and 91 vs 79 bpm; p < 0.01). QT and PR space were significantly extended (360 vs 384 ms and 133 vs 172 ms; p = 0.01). It increases QRS complex and blood pressure response to sustained handgrip but failed to modify previously decreased heart response to deep breathing. HRV parameters such as SDNN, RMSSD, LF, HF and sympathovagal balance estimate by HF/LF ratio remained unchanged. Although a significant reduction in heart excitability, propanolol failed to restore a good sympathovagal balance in hyperthyroidism. Trial registration NCT03393728 "Retrospectively registered".

  9. Using time-frequency analysis of the photoplethysmographic waveform to detect the withdrawal of 900 mL of blood.

    PubMed

    Scully, Christopher G; Selvaraj, Nandakumar; Romberg, Frederick W; Wardhan, Richa; Ryan, John; Florian, John P; Silverman, David G; Shelley, Kirk H; Chon, Ki H

    2012-07-01

    We designed this study to determine if 900 mL of blood withdrawal during spontaneous breathing in healthy volunteers could be detected by examining the time-varying spectral amplitude of the photoplethysmographic (PPG) waveform in the heart rate frequency band and/or in the breathing rate frequency band before significant changes occurred in heart rate or arterial blood pressure. We also identified the best PPG probe site for early detection of blood volume loss by testing ear, finger, and forehead sites. Eight subjects had 900 mL of blood withdrawn followed by reinfusion of 900 mL of blood. Physiological monitoring included PPG waveforms from ear, finger, and forehead probe sites, standard electrocardiogram, and standard blood pressure cuff measurements. The time-varying amplitude sequences in the heart rate frequency band and breathing rate frequency band present in the PPG waveform were extracted from high-resolution time-frequency spectra. These amplitudes were used as a parameter for blood loss detection. Heart rate and arterial blood pressure did not significantly change during the protocol. Using time-frequency analysis of the PPG waveform from ear, finger, and forehead probe sites, the amplitude signal extracted at the frequency corresponding to the heart rate significantly decreased when 900 mL of blood was withdrawn, relative to baseline (all P < 0.05); for the ear, the corresponding signal decreased when only 300 mL of blood was withdrawn. The mean percent decrease in the amplitude of the heart rate component at 900 mL blood loss relative to baseline was 45.2% (38.2%), 42.0% (29.2%), and 42.3% (30.5%) for ear, finger, and forehead probe sites, respectively, with the lower 95% confidence limit shown in parentheses. After 900 mL blood reinfusion, the amplitude signal at the heart rate frequency showed a recovery towards baseline. There was a clear separation of amplitude values at the heart rate frequency between baseline and 900 mL blood withdrawal. Specificity and sensitivity were both found to be 87.5% with 95% confidence intervals (47.4%, 99.7%) for ear PPG signals for a chosen threshold value that was optimized to separate the 2 clusters of amplitude values (baseline and blood loss) at the heart rate frequency. Meanwhile, no significant changes in the spectral amplitude in the frequency band corresponding to respiration were found. A time-frequency spectral method detected blood loss in spontaneously breathing subjects before the onset of significant changes in heart rate or blood pressure. Spectral amplitudes at the heart rate frequency band were found to significantly decrease during blood loss in spontaneously breathing subjects, whereas those at the breathing rate frequency band did not significantly change. This technique may serve as a valuable tool in intraoperative and trauma settings to detect and monitor hemorrhage.

  10. Development and Validation of an Agency for Healthcare Research and Quality Indicator for Mortality After Congenital Heart Surgery Harmonized With Risk Adjustment for Congenital Heart Surgery (RACHS-1) Methodology.

    PubMed

    Jenkins, Kathy J; Koch Kupiec, Jennifer; Owens, Pamela L; Romano, Patrick S; Geppert, Jeffrey J; Gauvreau, Kimberlee

    2016-05-20

    The National Quality Forum previously approved a quality indicator for mortality after congenital heart surgery developed by the Agency for Healthcare Research and Quality (AHRQ). Several parameters of the validated Risk Adjustment for Congenital Heart Surgery (RACHS-1) method were included, but others differed. As part of the National Quality Forum endorsement maintenance process, developers were asked to harmonize the 2 methodologies. Parameters that were identical between the 2 methods were retained. AHRQ's Healthcare Cost and Utilization Project State Inpatient Databases (SID) 2008 were used to select optimal parameters where differences existed, with a goal to maximize model performance and face validity. Inclusion criteria were not changed and included all discharges for patients <18 years with International Classification of Diseases, Ninth Revision, Clinical Modification procedure codes for congenital heart surgery or nonspecific heart surgery combined with congenital heart disease diagnosis codes. The final model includes procedure risk group, age (0-28 days, 29-90 days, 91-364 days, 1-17 years), low birth weight (500-2499 g), other congenital anomalies (Clinical Classifications Software 217, except for 758.xx), multiple procedures, and transfer-in status. Among 17 945 eligible cases in the SID 2008, the c statistic for model performance was 0.82. In the SID 2013 validation data set, the c statistic was 0.82. Risk-adjusted mortality rates by center ranged from 0.9% to 4.1% (5th-95th percentile). Congenital heart surgery programs can now obtain national benchmarking reports by applying AHRQ Quality Indicator software to hospital administrative data, based on the harmonized RACHS-1 method, with high discrimination and face validity. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  11. An ergonomic approach to design hand tool for agricultural production.

    PubMed

    Khidiya, Mahendra Singh; Bhardwaj, Awadhesh

    2012-01-01

    Hand tool mechanisms designed to reduce the risk factors have rarely been studied. In this paper it is analyze trowel firstly designing in CATIA and then its Finite Element Analysis has been carried out by ABAQUS. The main emphasis is on finding stresses by using this software, then removing them by suitable mechanical working on tool & ergonomic change in the design of handle to make it more comfortable. Body part discomfort score and overall discomfort rating experienced by the subjects had also been estimated. During the muscular activity workers physiological responses i.e. energy expenditure rate, oxygen consumption rate and heart rate increases. This increase in physiological responses is related to the type, intensity and duration of work and thus sets limits to the performance of heavy work. In this paper oxygen consumption rate and heart rate was used for physiological cost estimation. These parameters were measured by Computerized Ambulatory Metabolic Measurement System K4b2.

  12. [Evaluation of autonomic nervous system function with heart rate variability analysis in patients with hyperthyroidism and during euthyroidism after pharmacologic and surgical treatment].

    PubMed

    Barczyński, M; Tabor, S; Thor, P

    1997-01-01

    The aim of the present study was both to estimate autonomic nervous system (ANS) function in patients with hyperthyroidism by the heart rate variability (HRV) analysis and to evaluate the impact of pharmacological and surgical treatment on the ANS function. Analysis of the HRV underwent 10 female patients in course of thyreotoxicosis and after reaching full clinical and biochemical euthyroidism, after pharmacological therapy and in month after surgical treatment. The 10 minutes records at rest, in horizontal position were evaluated. The HRV parameters like mean of the heart rate, mean of RR intervals, standard deviation of all normal RR intervals (SDNN), range of the heart rate variability, low frequency (LF), high frequency (HF) components of the heart rate power spectral density and LF/HF ratio were assessed. The results were compared to those obtained from 10 age-, sex-, and body mass index-matched control subjects. The statistical significance (p < 0.05) was found in reduction of range of RR intervals, in increase of LF/HF ratio and in decrease of SDNN in hyperthyroidism in comparison to the control group (151.6/346.8 ms; 2.4/0.74; 24.4/57.2 ms2). In course of pharmacological euthyroidism there were statistically significant (p < 0.05) increase of range of RR intervals, reduction of LF/HF ratio and increase of SDNN in comparison to hyperthyroidism (270/151.6 ms; 0.995/2.4; 39/24.4 ms2). In euthyroidism after surgical treatment all the above parameters kept the similar levels as in pharmacological euthyroidism (no statistical significance for p < 0.05). On the base of the outcomes it was considered that in hyperthyroid patients there is advantage of sympathetic part of ANS over parasympathetic one which is due to sharp reduction of parasympathetic system activity. Pharmacological therapy with thyreostatics normalises balance of ANS to the level of the control group and after surgical treatment the balance keeps the same. Moreover, in the estimation of ANS as important as LF/HF ratio is the mean range of RR intervals.

  13. Advancements in noncontact, multiparameter physiological measurements using a webcam.

    PubMed

    Poh, Ming-Zher; McDuff, Daniel J; Picard, Rosalind W

    2011-01-01

    We present a simple, low-cost method for measuring multiple physiological parameters using a basic webcam. By applying independent component analysis on the color channels in video recordings, we extracted the blood volume pulse from the facial regions. Heart rate (HR), respiratory rate, and HR variability (HRV, an index for cardiac autonomic activity) were subsequently quantified and compared to corresponding measurements using Food and Drug Administration-approved sensors. High degrees of agreement were achieved between the measurements across all physiological parameters. This technology has significant potential for advancing personal health care and telemedicine.

  14. Heart rate variability parameters in horses distinguish atrial fibrillation from sinus rhythm before and after successful electrical cardioversion.

    PubMed

    Broux, B; De Clercq, D; Decloedt, A; Ven, S; Vera, L; van Steenkiste, G; Mitchell, K; Schwarzwald, C; van Loon, G

    2017-11-01

    Atrial fibrillation (AF) is the most common pathological arrhythmia in horses. After successful treatment, recurrence is common. Heart rate monitors are easily applicable in horses and some devices offer basic heart rate variability (HRV) calculations. If HRV can be used to distinguish between AF and sinus rhythm (SR), this could become a monitoring tool for horses at risk for recurrence of AF. The purpose of this study was to assess whether in horses AF (before cardioversion) and SR (after cardioversion) can be differentiated based upon HRV parameters. Cohort study with internal controls. Six HRV parameters were determined in 20 horses, both in AF and in SR, at rest (2- and 5-min and 1- and 4-h recordings) and during exercise (walk and trot, 2-min recordings). Time-domain (standard deviation of the NN intervals, root mean squared successive differences in NN intervals and triangular index), frequency domain (low/high frequency ratio) and nonlinear parameters (standard deviation of the Poincaré plot [SD]1 and SD2) were used. Statistical analysis was done using paired Wilcoxon signed rank tests and receiver operating characteristic curves. HRV was higher during AF compared to SR. Results for the detection of AF were good (area under the receiver operating characteristic curve [AUC] 0.8-1) for most HRV parameters. Root mean squared successive differences in NN intervals and SD1 yielded the best results (AUC 0.9-1). Sensitivity and specificity were high for all parameters at all recordings, but highest during exercise. Although AUCs improved with longer recordings, short recordings were also good (AUC 0.8-1) for the detection of AF. In horses with frequent second degree atrioventricular block, HRV at rest is increased and recordings at walk or trot are recommended. Animals served as their own controls and there was no long-term follow-up to identify AF recurrence. AF (before cardioversion) and SR (after cardioversion) could be distinguished with HRV. This technique has promise as a monitoring tool in horses at risk for AF development. © 2017 EVJ Ltd.

  15. Stress responses to comparative handling procedures in sheep.

    PubMed

    Yardimci, M; Sahin, E H; Cetingul, I S; Bayram, I; Aslan, R; Sengor, E

    2013-01-01

    The objective of this study was to compare some husbandry procedures on the base of physiological stress parameters and evaluate the welfare status in sheep. Forty ewes were used as the study material. Measurements were taken during several routine husbandry procedures such as milking, shearing, weighing, loading and hoof care. Data regarding time spent for each application, as well as heart and respiratory rates were recorded during the applications. Blood samples were taken 15 min before and after each application and malondialdehyde (MDA), glutathione-peroxidase (GSH-Px), cortisol T(3) and T(4) parameters were measured. In addition, changes in the same parameters between pre- and post-application periods were evaluated. According to the results, machine milking caused less stress than hand milking. No significant difference was seen between shearing methods for hand shearer or clipper; however, both applications caused stress in animals. The results for weighing methods of animals demonstrated significant differences in cortisol, T(3) and T(4) values in favor of traditional method. Cortisol, T(3) and T(4) levels were significantly higher in manual loading compared with loading by ramp. Regarding hoof care, all the examined parameters differed in favor of modern method. On the other hand, significant differences were determined between the stress parameters regarding pre- and post-applications. All values differed for hand milking while no significant difference was observed in MDA and T(3) values in machine milking group. Parameters in weighing groups changed significantly. For loading process, GSH, cortisol, T(3) and T(4) values differed in both treatment groups. With regard to hoof care, parameters except T(4) in laying group differed significantly. An increase occurred in minute-based measurements of heart and respiratory rates parallel to physiological data. The number of the respiratory rates during the applications differed except for the shearing process. All the parameters displayed significant differences between groups in terms of heart rates. Time spent for each application also differed between groups. Time saved for milking, shearing, weighing, loading and hoof care was 3.23 min, 4.37 min, 1.71 min, 7.85 s and 1.55 min, respectively. These results appear to provide a tangible advantage of using new husbandry methods to the breeders. It was concluded that using new methods in sheep husbandry procedures provided advantages in terms of saving time and reducing labor, as well as improved conditions for welfare of animals. In addition, it facilitated the routine works and flock husbandry.

  16. Detection and evaluation of ventricular repolarization alternans: an approach to combined ECG, thoracic impedance, and beat-to-beat heart rate variability analysis.

    PubMed

    Kriščiukaitis, Algimantas; Šimoliūnienė, Renata; Macas, Andrius; Petrolis, Robertas; Drėgūnas, Kęstutis; Bakšytė, Giedrė; Pieteris, Linas; Bertašienė, Zita; Žaliūnas, Remigijus

    2014-01-01

    Beat-to-beat alteration in ventricles repolarization reflected by alternans of amplitude and/or shape of ECG S-T,T segment (TWA) is known as phenomena related with risk of severe arrhythmias leading to sudden cardiac death. Technical difficulties have caused limited its usage in clinical diagnostics. Possibilities to register and analyze multimodal signals reflecting heart activity inspired search for new technical solutions. First objective of this study was to test whether thoracic impedance signal and beat-to-beat heart rate reflect repolarization alternans detected as TWA. The second objective was revelation of multimodal signal features more comprehensively representing the phenomena and increasing its prognostic usefulness. ECG, and thoracic impedance signal recordings made during 24h follow-up of the patients hospitalized in acute phase of myocardial infarction were used for investigation. Signal morphology variations reflecting estimates were obtained by the principal component analysis-based method. Clinical outcomes of patients (survival and/or rehospitalization in 6 and 12 months) were compared to repolarization alternans and heart rate variability estimates. Repolarization alternans detected as TWA was also reflected in estimates of thoracic impedance signal shape and variation in beat-to-beat heart rate. All these parameters showed correlation with clinical outcomes of patients. The strongest significant correlation showed magnitude of alternans in estimates of thoracic impedance signal shape. The features of ECG, thoracic impedance signal and beat-to-beat variability of heart rate, give comprehensive estimates of repolarization alternans, which correlate, with clinical outcomes of the patients and we recommend using them to improve diagnostic reliability. Copyright © 2014 Lithuanian University of Health Sciences. Production and hosting by Elsevier Urban & Partner Sp. z o.o. All rights reserved.

  17. Selection and collection of multi parameter physiological data for cardiac rhythm diagnostic algorithm development

    NASA Astrophysics Data System (ADS)

    Bostock, J.; Weller, P.; Cooklin, M.

    2010-07-01

    Automated diagnostic algorithms are used in implantable cardioverter-defibrillators (ICD's) to detect abnormal heart rhythms. Algorithms misdiagnose and improved specificity is needed to prevent inappropriate therapy. Knowledge engineering (KE) and artificial intelligence (AI) could improve this. A pilot study of KE was performed with artificial neural network (ANN) as AI system. A case note review analysed arrhythmic events stored in patients ICD memory. 13.2% patients received inappropriate therapy. The best ICD algorithm had sensitivity 1.00, specificity 0.69 (p<0.001 different to gold standard). A subset of data was used to train and test an ANN. A feed-forward, back-propagation network with 7 inputs, a 4 node hidden layer and 1 output had sensitivity 1.00, specificity 0.71 (p<0.001). A prospective study was performed using KE to list arrhythmias, factors and indicators for which measurable parameters were evaluated and results reviewed by a domain expert. Waveforms from electrodes in the heart and thoracic bio-impedance; temperature and motion data were collected from 65 patients during cardiac electrophysiological studies. 5 incomplete datasets were due to technical failures. We concluded that KE successfully guided selection of parameters and ANN produced a usable system and that complex data collection carries greater risk of technical failure, leading to data loss.

  18. [Shock shape representation of sinus heart rate based on cloud model].

    PubMed

    Yin, Wenfeng; Zhao, Jie; Chen, Tiantian; Zhang, Junjian; Zhang, Chunyou; Li, Dapeng; An, Baijing

    2014-04-01

    The present paper is to analyze the trend of sinus heart rate RR interphase sequence after a single ventricular premature beat and to compare it with the two parameters, turbulence onset (TO) and turbulence slope (TS). Based on the acquisition of sinus rhythm concussion sample, we in this paper use a piecewise linearization method to extract its linear characteristics, following which we describe shock form with natural language through cloud model. In the process of acquisition, we use the exponential smoothing method to forecast the position where QRS wave may appear to assist QRS wave detection, and use template to judge whether current cardiac is sinus rhythm. And we choose some signals from MIT-BIH Arrhythmia Database to detect whether the algorithm is effective in Matlab. The results show that our method can correctly detect the changing trend of sinus heart rate. The proposed method can achieve real-time detection of sinus rhythm shocks, which is simple and easily implemented, so that it is effective as a supplementary method.

  19. Short-term vs. long-term heart rate variability in ischemic cardiomyopathy risk stratification.

    PubMed

    Voss, Andreas; Schroeder, Rico; Vallverdú, Montserrat; Schulz, Steffen; Cygankiewicz, Iwona; Vázquez, Rafael; Bayés de Luna, Antoni; Caminal, Pere

    2013-01-01

    In industrialized countries with aging populations, heart failure affects 0.3-2% of the general population. The investigation of 24 h-ECG recordings revealed the potential of nonlinear indices of heart rate variability (HRV) for enhanced risk stratification in patients with ischemic heart failure (IHF). However, long-term analyses are time-consuming, expensive, and delay the initial diagnosis. The objective of this study was to investigate whether 30 min short-term HRV analysis is sufficient for comparable risk stratification in IHF in comparison to 24 h-HRV analysis. From 256 IHF patients [221 at low risk (IHFLR) and 35 at high risk (IHFHR)] (a) 24 h beat-to-beat time series (b) the first 30 min segment (c) the 30 min most stationary day segment and (d) the 30 min most stationary night segment were investigated. We calculated linear (time and frequency domain) and nonlinear HRV analysis indices. Optimal parameter sets for risk stratification in IHF were determined for 24 h and for each 30 min segment by applying discriminant analysis on significant clinical and non-clinical indices. Long- and short-term HRV indices from frequency domain and particularly from nonlinear dynamics revealed high univariate significances (p < 0.01) discriminating between IHFLR and IHFHR. For multivariate risk stratification, optimal mixed parameter sets consisting of 5 indices (clinical and nonlinear) achieved 80.4% AUC (area under the curve of receiver operating characteristics) from 24 h HRV analysis, 84.3% AUC from first 30 min, 82.2 % AUC from daytime 30 min and 81.7% AUC from nighttime 30 min. The optimal parameter set obtained from the first 30 min showed nearly the same classification power when compared to the optimal 24 h-parameter set. As results from stationary daytime and nighttime, 30 min segments indicate that short-term analyses of 30 min may provide at least a comparable risk stratification power in IHF in comparison to a 24 h analysis period.

  20. Ultrasound Current Source Density Imaging in live rabbit hearts using clinical intracardiac catheter

    NASA Astrophysics Data System (ADS)

    Li, Qian

    Ultrasound Current Source Density Imaging (UCSDI) is a noninvasive modality for mapping electrical activities in the body (brain and heart) in 4-dimensions (space + time). Conventional cardiac mapping technologies for guiding the radiofrequency ablation procedure for treatment of cardiac arrhythmias have certain limitations. UCSDI can potentially overcome these limitations and enhance the electrophysiology mapping of the heart. UCSDI exploits the acoustoelectric (AE) effect, an interaction between ultrasound pressure and electrical resistivity. When an ultrasound beam intersects a current path in a material, the local resistivity of the material is modulated by the ultrasonic pressure, and a change in voltage signal can be detected based on Ohm's Law. The degree of modulation is determined by the AE interaction constant K. K is a fundamental property of any type of material, and directly affects the amplitude of the AE signal detected in UCSDI. UCSDI requires detecting a small AE signal associated with electrocardiogram. So sensitivity becomes a major challenge for transferring UCSDI to the clinic. This dissertation will determine the limits of sensitivity and resolution for UCSDI, balancing the tradeoff between them by finding the optimal parameters for electrical cardiac mapping, and finally test the optimized system in a realistic setting. This work begins by describing a technique for measuring K, the AE interaction constant, in ionic solution and biological tissue, and reporting the value of K in excised rabbit cardiac tissue for the first time. K was found to be strongly dependent on concentration for the divalent salt CuSO4, but not for the monovalent salt NaCl, consistent with their different chemical properties. In the rabbit heart tissue, K was determined to be 0.041 +/- 0.012 %/MPa, similar to the measurement of K in physiologic saline: 0.034 +/- 0.003 %/MPa. Next, this dissertation investigates the sensitivity limit of UCSDI by quantifying the relation between the recording electrode distance and the measured AE signal amplitude in gel phantoms and excised porcine heart tissue using a clinical intracardiac catheter. Sensitivity of UCSDI with catheter was 4.7 microV/mA (R2 = 0.999) in cylindrical gel (0.9% NaCl), and 3.2 microV/mA (R2 = 0.92) in porcine heart tissue. The AE signal was detectable more than 25 mm away from the source in cylindrical gel (0.9% NaCl). Effect of transducer properties on UCSDI sensitivity is also investigated using simulation. The optimal ultrasound transducer parameters chosen for cardiac imaging are center frequency = 0.5 MHz and f/number = 1.4. Last but not least, this dissertation shows the result of implementing the optimized ultrasound parameters in live rabbit heart preparation, the comparison of different recording electrode configuration and multichannel UCSDI recording and reconstruction. The AE signal detected using the 0.5 MHz transducer was much stronger (2.99 microV/MPa) than the 1.0 MHz transducer (0.42 microV/MPa). The clinical lasso catheter placed on the epicardium exhibited excellent sensitivity without being too invasive. 3-dimensional cardiac activation maps of the live rabbit heart using only one pair of recording electrodes were also demonstrated for the first time. Cardiac conduction velocity for atrial (1.31 m/s) and apical (0.67 m/s) pacing were calculated based on the activation maps. The future outlook of this dissertation includes integrating UCSDI with 2-dimensional ultrasound transducer array for fast imaging, and developing a multi-modality catheter with 4-dimensional UCSDI, multi-electrode recording and echocardiography capacity.

  1. Effect of 400 ml blood loss on adaptation of certain functions of the organism to exercise.

    PubMed

    Markiewicz, K; Cholewa, M; Górski, L; Jaszczuk, J; Chmura, J; Bartniczak, Z

    1981-01-01

    Eighteen men aged 19-23 years, volunteer blood donors, donated 400 ml of blood. Twenty-four hours before donation, one hour and 24 hours after it they performed a 10-minute exercise on Monark cycle ergometer at workloads raising the heart rate to 170/min. During the exercise the oxygen uptake (VO2), carbon dioxide elimination (VCO2), respiratory quotient (RQ), oxygen uptake to maximal oxygen uptake ratio (VO2/VO2 max), heart rate (HR) and systolic and diastolic arterial blood pressure (Ps and Pd) were determined. The obtained results were compared with the values of haemoglobin concentration and erythrocyte count. One hour after blood donation raised values of HR and Pd were obtained (p less than 0.05) with decreased Ps (p less than 0.05) and VO2 (p less than 0.05). Twenty-four hours after blood loss these parameters were not different from the initial ones (p less than 0.05). Submaximal exercise performed 1 hour after blood loss produced a significantly greater increase of the heart rate than this exercise performed before blood loss. The values of VO2, VCO2, and VO2/VO2 max were slightly lower and those of RQ and HRXPs slightly higher than during control exercise (p less than 0.05). Exercise performed 24 hours after blood loss caused identical changes in these parameters as during control tests.

  2. Integrated system for remotely monitoring critical physiological parameters

    NASA Astrophysics Data System (ADS)

    Alexakis, S.; Karalis, S.; Asvestas, P.

    2015-09-01

    Monitoring several human parameters (temperature, heart rate, blood pressure etc.) is an essential task in health care in hospitals as well as in home care. This paper presents the design and implementation of an integrated, embedded system that includes an electrocardiograph of nine leads and two channels, a digital thermometer for measuring the body temperature and a power supply. The system provides networking capabilities (wired or wireless) and is accessible by means of a web interface that allows the user to select the leads, as well as to review the values of heart rate (beats per minute) and body temperature. Furthermore, there is the option of saving all the data in a Micro SD memory card or in a Google Spreadsheet. The necessary analog circuits for signal conditioning (amplification and filtering) were manufactured on printed circuit boards (PCB). The system was built around Arduino Yun, which is a platform that contains a microcontroller and a microprocessor running a special LINUX distribution. Furthermore, the Arduino Yun provides the necessary network connectivity capabilities by means of the integrated Wi-Fi and Ethernet interfaces. The web interface was developed using HTML pages with JavaScript support. The system was tested on simulated data as well as real data, providing satisfactory accuracy regarding the measurement of the heart rate (±3 bpm error) and the temperature (±0.3°C error).

  3. Prediction of multi performance characteristics of wire EDM process using grey ANFIS

    NASA Astrophysics Data System (ADS)

    Kumanan, Somasundaram; Nair, Anish

    2017-09-01

    Super alloys are used to fabricate components in ultra-supercritical power plants. These hard to machine materials are processed using non-traditional machining methods like Wire cut electrical discharge machining and needs attention. This paper details about multi performance optimization of wire EDM process using Grey ANFIS. Experiments are designed to establish the performance characteristics of wire EDM such as surface roughness, material removal rate, wire wear rate and geometric tolerances. The control parameters are pulse on time, pulse off time, current, voltage, flushing pressure, wire tension, table feed and wire speed. Grey relational analysis is employed to optimise the multi objectives. Analysis of variance of the grey grades is used to identify the critical parameters. A regression model is developed and used to generate datasets for the training of proposed adaptive neuro fuzzy inference system. The developed prediction model is tested for its prediction ability.

  4. Combined pulse-oximeter-NIRS system for biotissue diagnostics

    NASA Astrophysics Data System (ADS)

    Hovhannisyan, Vladimir A.

    2005-08-01

    Multi-wavelength (670, 805, 848 and 905 nm), multi-detector device for non-invasive measurement of biochemical components concentration in human or animal tissues, combining the methods of conventional pulse-oximetry and near infrared spectroscopy, is developed. The portable and clinically applicable system allows to measure heart pulse rate, oxygen saturation of arterial hemoglobin (pulse-oximetry method) and local absolute concentration of oxyhemoglobin, deoxyhemoglobin and oxidized cytochrome aa3 or other IR absorbed compounds (NIRS method). The system can be applied in monitoring of oxygen availability and utilization by the brain in neonatal and adults, neuro- traumatology, intensive care medicine, transplantation and plastic surgery, in sport, high-altitude and aviation medicine.

  5. [The effects of work in an air-conditioned cabin and stay in a resting chamber on blood pressure and heart rate of operators employed in deep copper mines].

    PubMed

    Borodulin-Nadzieja, L; Janocha, A; Pietraszkiewicz, T; Salomon, E; Stańda, M

    2001-01-01

    This paper is part of a wider comparative study of the heart rate, blood pressure, external and core temperature in operators of self-propelled mining machines with and without air-conditioning cabins. Two groups, each of ten operators, characterised by the similar age and duration of employment, stayed for 20 min a specially prepared resting chamber with much more advantageous microclimatic conditions. The results of our examinations (Holter heart rate and continuous blood pressure recordings, external and core temperature measurements) revealed that during the work (particularly during the increased work-load) all parameters recorded were significantly lower in air-conditioning cabins as compared with the group working without air-condition. In both groups, a complete restitution of the heart rate and blood pressure was observed after a 20-min stay in the resting chamber. During the work, a statistically significant increase in the external temperature was found in both groups of operators, whereas the increase in the core temperature was observed only in operators working without air-condition. After a 20-min stay in the resting chamber, a complete return to the normal temperature was noted only in operators working in air-conditioned cabins.

  6. Heart rate and heart rate variability modification in chronic insomnia patients.

    PubMed

    Farina, Benedetto; Dittoni, Serena; Colicchio, Salvatore; Testani, Elisa; Losurdo, Anna; Gnoni, Valentina; Di Blasi, Chiara; Brunetti, Riccardo; Contardi, Anna; Mazza, Salvatore; Della Marca, Giacomo

    2014-01-01

    Chronic insomnia is highly prevalent in the general population, provoking personal distress and increased risk for psychiatric and medical disorders. Autonomic hyper-arousal could be a pathogenic mechanism of chronic primary insomnia. The aim of this study was to investigate autonomic activity in patients with chronic primary insomnia by means of heart rate variability (HRV) analysis. Eighty-five consecutive patients affected by chronic primary insomnia were enrolled (38 men and 47 women; mean age: 53.2 ± 13.6). Patients were compared with a control group composed of 55 healthy participants matched for age and gender (23 men and 32 women; mean age: 54.2 ± 13.9). Patients underwent an insomnia study protocol that included subjective sleep evaluation, psychometric measures, and home-based polysomnography with evaluation of HRV in wake before sleep, in all sleep stages, and in wake after final awakening. Patients showed modifications of heart rate and HRV parameters, consistent with increased sympathetic activity, while awake before sleep and during Stage-2 non-REM sleep. No significant differences between insomniacs and controls could be detected during slow-wave sleep, REM sleep, and post-sleep wake. These results are consistent with the hypothesis that autonomic hyper-arousal is a major pathogenic mechanism in primary insomnia, and confirm that this condition is associated with an increased cardiovascular risk.

  7. Levels of maximum end-expiratory carbon monoxide and certain cardiovascular parameters following hubble-bubble smoking.

    PubMed

    Shafagoj, Yanal A; Mohammed, Faisal I

    2002-08-01

    The physiological effects of cigarette smoking have been widely studied, however, little is known regarding the effects of smoking hubble-bubble. We examined the acute effects of hubble-bubble smoking on heart rate, systolic, diastolic, and mean arterial blood pressure and maximum end-expiratory carbon monoxide. This study was carried out in the student laboratory, School of Medicine, Department of Physiology, University of Jordan, Amman, Jordan, during the summer of 1999. In 18 healthy habitual hubble-bubble smokers, heart rate, blood pressure, and maximum end-expiratory carbon monoxide was measured before, during and post smoking of one hubble-bubble run (45 minutes). Compared to base line (time zero), at the end of smoking heart rate, systolic blood pressure, diastolic blood pressure, mean arterial blood pressure, and maximum end-expiratory carbon monoxide were increased 16 2.4 beats per minute, 6.7 2.5 mm Hg, 4.4 1.6 mm Hg, 5.2 1.7 mm Hg, and 14.2 1.8 ppm, (mean standard error of mean, P<.05). Acute short-term active hubble-bubble smoking elicits a modest increase in heart rate, systolic blood pressure, diastolic blood pressure, mean arterial blood pressure and maximum end-expiratory carbon monoxide in healthy hubble-bubble smokers.

  8. Development of an anaerobic threshold (HRLT, HRVT) estimation equation using the heart rate threshold (HRT) during the treadmill incremental exercise test

    PubMed Central

    Ham, Joo-ho; Park, Hun-Young; Kim, Youn-ho; Bae, Sang-kon; Ko, Byung-hoon

    2017-01-01

    [Purpose] The purpose of this study was to develop a regression model to estimate the heart rate at the lactate threshold (HRLT) and the heart rate at the ventilatory threshold (HRVT) using the heart rate threshold (HRT), and to test the validity of the regression model. [Methods] We performed a graded exercise test with a treadmill in 220 normal individuals (men: 112, women: 108) aged 20–59 years. HRT, HRLT, and HRVT were measured in all subjects. A regression model was developed to estimate HRLT and HRVT using HRT with 70% of the data (men: 79, women: 76) through randomization (7:3), with the Bernoulli trial. The validity of the regression model developed with the remaining 30% of the data (men: 33, women: 32) was also examined. [Results] Based on the regression coefficient, we found that the independent variable HRT was a significant variable in all regression models. The adjusted R2 of the developed regression models averaged about 70%, and the standard error of estimation of the validity test results was 11 bpm, which is similar to that of the developed model. [Conclusion] These results suggest that HRT is a useful parameter for predicting HRLT and HRVT. PMID:29036765

  9. Development of an anaerobic threshold (HRLT, HRVT) estimation equation using the heart rate threshold (HRT) during the treadmill incremental exercise test.

    PubMed

    Ham, Joo-Ho; Park, Hun-Young; Kim, Youn-Ho; Bae, Sang-Kon; Ko, Byung-Hoon; Nam, Sang-Seok

    2017-09-30

    The purpose of this study was to develop a regression model to estimate the heart rate at the lactate threshold (HRLT) and the heart rate at the ventilatory threshold (HRVT) using the heart rate threshold (HRT), and to test the validity of the regression model. We performed a graded exercise test with a treadmill in 220 normal individuals (men: 112, women: 108) aged 20-59 years. HRT, HRLT, and HRVT were measured in all subjects. A regression model was developed to estimate HRLT and HRVT using HRT with 70% of the data (men: 79, women: 76) through randomization (7:3), with the Bernoulli trial. The validity of the regression model developed with the remaining 30% of the data (men: 33, women: 32) was also examined. Based on the regression coefficient, we found that the independent variable HRT was a significant variable in all regression models. The adjusted R2 of the developed regression models averaged about 70%, and the standard error of estimation of the validity test results was 11 bpm, which is similar to that of the developed model. These results suggest that HRT is a useful parameter for predicting HRLT and HRVT. ©2017 The Korean Society for Exercise Nutrition

  10. Multi-Parameter Linear Least-Squares Fitting to Poisson Data One Count at a Time

    NASA Technical Reports Server (NTRS)

    Wheaton, W.; Dunklee, A.; Jacobson, A.; Ling, J.; Mahoney, W.; Radocinski, R.

    1993-01-01

    A standard problem in gamma-ray astronomy data analysis is the decomposition of a set of observed counts, described by Poisson statistics, according to a given multi-component linear model, with underlying physical count rates or fluxes which are to be estimated from the data.

  11. Computerized fetal heart rate monitoring after vibroacoustic stimulation in the anencephalic fetus.

    PubMed

    Park, Yong-Jin; Park, Seon-Hye; Kim, Young-Jae; Hoh, Jeong-Kyu; Park, Young-Sun; Park, Moon-Il

    2010-09-01

    To quantify changes in fetal heart rate (FHR) parameters after vibroacoustic stimulation (VAS) and to evaluate the usefulness of VAS testing (VAST) in anencephalic fetuses. Our findings may also help to clarify the route(s) of vibration and sound transmission during VAST. We obtained the antepartum FHR tracings of 16 anencephalic fetuses, including both the nonstress test (NST) and VAST. Using a computerized monitoring system, HYFM, we determined all FHR parameters from data collected for 10 min before and 10 min after VAS, at successive gestational stages. We observed three false reactive responses at term. The false reactive rate for VAST (3/16) was higher than that for NST (1/16). No FHR parameters increased significantly after VAS except for the number of fetal movements (FM), which increased significantly in all gestational groups (25th-32nd and 33rd-40th weeks). These findings call attention to an increased probability of a false reactive response in VAST analysis, when the fetus is affected by a CNS disorder. Increased numbers of FM after VAS suggest that the vibratory pathway is more likely to elicit fetal response than the auditory pathway in this setting, and that the vibratory stimulation travels by subcortical rather than by cortical pathways. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  12. The Six Minute Walk Test Revisited

    NASA Astrophysics Data System (ADS)

    Mazumder, M.

    2017-12-01

    Background and Purpose: Heart failure is the leading cause of death and often alters or severely restricts human mobility, an essential life function. Motion capture is an emerging tool for analyzing human movement and extremity articulation, providing quantitative information on gait and range of motion. This study uses BioStamp mechanosensors to identify differences in motion for the duration of the Six Minute Walk Test and signature patterns of muscle contraction and posture in patients with advanced heart failure compared to healthy subjects. Identification and close follow up of these patterns may allow enhanced diagnosis and the possibility for early intervention before disease worsening. Additionally, movement parameters represent a new family of potential biomarkers to track heart failure onset, progression and therapy. Methods: Prior to the Six Minute Walk Test, BioStamps (MC10) were applied to the chest, upper and lower extremities of heart failure and healthy patients and data were streamed and recorded revealing the pattern of movement in three separate axes. Conjointly, before and after the Six Minute Walk Test, the following vitals were measured per subject: heart rate, respiratory rate, blood pressure, oxygen saturation, dyspnea and leg fatigue (self-reported with Borg scale). During the test, patients were encouraged to walk as far as they can in 6 minutes on a 30m course, as we recorded the number of laps completed and oxygen saturation every minute. Results and Conclusions: The sensors captured and quantified whole body and regional motion parameters including: a. motion extent, position, acceleration and angle via incorporated accelerometers and gyroscopes; b. muscle contraction via incorporated electromyogram (EMG). Accelerometry and gyroscopic data for the last five steps of a healthy and heart failure patient are shown. While significant differences in motion for the duration of the test were not found, each category of patients had a distinct pattern of motion - with identifiable qualitative and quantitative differences. These wearable conformal skin adherent sensors allow on-body, mobile, personalized determination of motion and flexibility parameters. This tool and method hold promise for providing motion "biomarker" data in health and disease.

  13. Nitrates as a Treatment of Acute Heart Failure

    PubMed Central

    Alzahri, Mohammad S; Rohra, Anita

    2016-01-01

    The purpose of this article is to review the clinical efficacy and safety of nitrates in acute heart failure (AHF) by examining various trials on nitrates in AHF. Management of AHF can be challenging due to the lack of objective clinical evidence guiding optimal management. There have been many articles suggesting that, despite a benefit, nitrates are underused in clinical practice. Nitrates, when appropriately dosed, have a favourable effect on symptoms, blood pressure, intubation rates, mortality and other parameters. PMID:28785453

  14. [Evaluation of maternal parameters as risk factors for premature birth (individual and combined effects)].

    PubMed

    Voigt, M; Briese, V; Pietzner, V; Kirchengast, S; Schneider, K T M; Straube, S; Jorch, G

    2009-08-01

    We aimed to examine the individual and combined effects of nine maternal parameters (biological, medical, and social) on rates of prematurity. Our objective was to provide obstetricians with a way of screening women for likely premature deliveries. We conducted a retrospective analysis on the data of about 2.3 million pregnancies taken from the German perinatal statistics of 1995-2000. Rates of prematurity were calculated with single and multi-dimensional analyses on the basis of nine maternal parameters (age, weight, height, number of previous live births, stillbirths, miscarriages and terminations of pregnancy, smoking status, previous premature delivery). The following combinations of parameters were investigated in particular: rates of prematurity according to the number of previous stillbirths, miscarriages, and terminations; rates of prematurity according to the number of previous live births and maternal age, height and weight. We also included daily cigarette consumption and previous premature deliveries in our analyses. The rate of prematurity (< or =36 weeks of gestation) in our population was 7.0%; the rate of moderately early premature deliveries (32-36 weeks) was 5.9%, and the rate of very early premature deliveries (< or =31 weeks) was 1.1%. Our multi-dimensional analyses revealed rates of prematurity (< or =36 weeks) between 5.1% and 27.5% depending on the combination of parameters. We found the highest rate of prematurity of 27.5% in women with the following combination of parameters: > or =1 stillbirth, > or =2 terminations of pregnancy and > or =2 miscarriages. A rather high risk of premature delivery (>11%) was also found for elderly (> or =40 years) grand multiparous women as well as small (< or =155 cm) and slim women (< or =45 kg). We have shown that certain combinations of maternal parameters are associated with a high risk of premature deliveries (>10%). The risk table that we present here may assist in predicting premature delivery. Georg Thieme Verlag KG Stuttgart.New York.

  15. Multi-complexity ensemble measures for gait time series analysis: application to diagnostics, monitoring and biometrics.

    PubMed

    Gavrishchaka, Valeriy; Senyukova, Olga; Davis, Kristina

    2015-01-01

    Previously, we have proposed to use complementary complexity measures discovered by boosting-like ensemble learning for the enhancement of quantitative indicators dealing with necessarily short physiological time series. We have confirmed robustness of such multi-complexity measures for heart rate variability analysis with the emphasis on detection of emerging and intermittent cardiac abnormalities. Recently, we presented preliminary results suggesting that such ensemble-based approach could be also effective in discovering universal meta-indicators for early detection and convenient monitoring of neurological abnormalities using gait time series. Here, we argue and demonstrate that these multi-complexity ensemble measures for gait time series analysis could have significantly wider application scope ranging from diagnostics and early detection of physiological regime change to gait-based biometrics applications.

  16. Psychophysiological responses to auditory change.

    PubMed

    Chuen, Lorraine; Sears, David; McAdams, Stephen

    2016-06-01

    A comprehensive characterization of autonomic and somatic responding within the auditory domain is currently lacking. We studied whether simple types of auditory change that occur frequently during music listening could elicit measurable changes in heart rate, skin conductance, respiration rate, and facial motor activity. Participants heard a rhythmically isochronous sequence consisting of a repeated standard tone, followed by a repeated target tone that changed in pitch, timbre, duration, intensity, or tempo, or that deviated momentarily from rhythmic isochrony. Changes in all parameters produced increases in heart rate. Skin conductance response magnitude was affected by changes in timbre, intensity, and tempo. Respiratory rate was sensitive to deviations from isochrony. Our findings suggest that music researchers interpreting physiological responses as emotional indices should consider acoustic factors that may influence physiology in the absence of induced emotions. © 2016 Society for Psychophysiological Research.

  17. Maximum sustained fin-kick thrust in underwater swimming.

    PubMed

    Yamaguchi, H; Shidara, F; Naraki, N; Mohri, M

    1995-09-01

    We examined the upper limit of a diver's fin-kick thrust force using a stationary-swimming ergometer. Heart rate, respiratory minute volume, oxygen uptake, and performance rate were measured in four male subjects who swam constantly for 8 min to maintain a horizontal position against an applied force at a depth of 0.7 m. The water temperature was controlled at 26 degrees +/- 1 degree C. The performance rate, which was the parameter of how well the subjects compensated for the applied load, showed an upper limit around 64 N of sustainable thrust force. This meant that the diver could generate the swimming thrust force within 64 N continuously for 8 min in a steady state. Heart rate, respiratory minute volume, and O2 uptake showed almost proportional increases to the applied load within 64 N and tended to plateau about 69 N.

  18. QRS classification and spatial combination for robust heart rate detection in low-quality fetal ECG recordings.

    PubMed

    Warmerdam, G; Vullings, R; Van Pul, C; Andriessen, P; Oei, S G; Wijn, P

    2013-01-01

    Non-invasive fetal electrocardiography (ECG) can be used for prolonged monitoring of the fetal heart rate (FHR). However, the signal-to-noise-ratio (SNR) of non-invasive ECG recordings is often insufficient for reliable detection of the FHR. To overcome this problem, source separation techniques can be used to enhance the fetal ECG. This study uses a physiology-based source separation (PBSS) technique that has already been demonstrated to outperform widely used blind source separation techniques. Despite the relatively good performance of PBSS in enhancing the fetal ECG, PBSS is still susceptible to artifacts. In this study an augmented PBSS technique is developed to reduce the influence of artifacts. The performance of the developed method is compared to PBSS on multi-channel non-invasive fetal ECG recordings. Based on this comparison, the developed method is shown to outperform PBSS for the enhancement of the fetal ECG.

  19. Predicting depressed patients with suicidal ideation from ECG recordings.

    PubMed

    Khandoker, A H; Luthra, V; Abouallaban, Y; Saha, S; Ahmed, K I; Mostafa, R; Chowdhury, N; Jelinek, H F

    2017-05-01

    Globally suicidal behavior is the third most common cause of death among patients with major depressive disorder (MDD). This study presents multi-lag tone-entropy (T-E) analysis of heart rate variability (HRV) as a screening tool for identifying MDD patients with suicidal ideation. Sixty-one ECG recordings (10 min) were acquired and analyzed from control subjects (29 CONT), 16 MDD subjects with (MDDSI+) and 16 without suicidal ideation (MDDSI-). After ECG preprocessing, tone and entropy values were calculated for multiple lags (m: 1-10). The MDDSI+ group was found to have a higher mean tone value compared to that of the MDDSI- group for lags 1-8, whereas the mean entropy value was lower in MDDSI+ than that in CONT group at all lags (1-10). Leave-one-out cross-validation tests, using a classification and regression tree (CART), obtained 94.83 % accuracy in predicting MDDSI+ subjects by using a combination of tone and entropy values at all lags and including demographic factors (age, BMI and waist circumference) compared to results with time and frequency domain HRV analysis. The results of this pilot study demonstrate the usefulness of multi-lag T-E analysis in identifying MDD patients with suicidal ideation and highlight the change in autonomic nervous system modulation of the heart rate associated with depression and suicidal ideation.

  20. Paradoxical dissociation between heart rate and heart rate variability following different modalities of exercise in individuals with metabolic syndrome: The RESOLVE study.

    PubMed

    Boudet, Gil; Walther, Guillaume; Courteix, Daniel; Obert, Philippe; Lesourd, Bruno; Pereira, Bruno; Chapier, Robert; Vinet, Agnès; Chamoux, Alain; Naughton, Geraldine; Poirier, Paul; Dutheil, Frédéric

    2017-02-01

    Aims To analyse the effects of different modalities of exercise training on heart rate variability (HRV) in individuals with metabolic syndrome (MetS). Methods and results Eighty MetS participants (aged 50-70 years) were housed and managed in an inpatient medical centre for 21 days, including weekends. Physical activity and food intake/diet were intensively monitored. Participants were randomly assigned into three training groups, differing only by intensity of exercise: moderate-endurance-moderate-resistance ( re), high-resistance-moderate-endurance ( Re), and moderate-resistance-high-endurance ( rE). HRV was recorded before and after the intervention by 24-hour Holter electrocardiogram. Although mean 24-hour heart rate decreased more in Re than re (-11.6 ± 1.6 vs. -4.8 ± 2.1%; P = 0.010), low frequency/high frequency decreased more in re than Re (-20.4 ± 5.5% vs. + 20.4 ± 9.1%; P = 0.002) and rE (-20.4 ± 5.5% vs. -0.3 ± 11.1%; P = 0.003). Very low frequency increased more in Re than re (+121.2 ± 35.7 vs. 42.9 ± 11.3%; P = 0.004). For all HRV parameters, rE ranged between re and Re values. Low frequency/high frequency changes were linked with visceral fat loss only in re (coefficient 5.9, 95% CI 1.9-10.0; P = 0.004). By day 21, HRV parameters of MetS groups (heart rate -8.6 ± 1.0%, standard deviation of R-R intervals + 34.0 ± 6.6%, total power + 63.3 ± 11.1%; P < 0.001) became closer to values of 50 aged-matched healthy controls. Conclusions A 3-week residential programme with intensive volumes of physical activity (15-20 hours per week) enhanced HRV in individuals with MetS. Participants with moderate intensity of training had greater improvements in sympathovagal balance, whereas those with high intensity in resistance training had greater decreases in heart rate and greater increases in very low frequency. Modality-specific relationships were observed between enhanced HRV and visceral fat loss. Clinical Trial Registration URL: http://www.clinicaltrials.gov . Unique identifier: NCT00917917.

  1. Strain and Torsion Quantification in Mouse Hearts under Dobutamine Stimulation using 2D Multi-Phase MR DENSE

    PubMed Central

    Zhong, Jia; Yu, Xin

    2010-01-01

    In the current study, a 2D multi-phase MR displacement encoding with stimulated echoes (DENSE) imaging and analysis method was developed for direct quantification of Lagrangian strain in the mouse heart. Using the proposed method, less than 10 ms temporal resolution and 0.56 mm in-plane resolution were achieved. A validation study that compared strain calculation by DENSE and by MR tagging showed high correlation between the two methods (R2 > 0.80). Regional ventricular wall strain and twist were characterized in mouse hearts at baseline and under dobutamine stimulation. Dobutamine stimulation induced significant increase in radial and circumferential strains and torsion at peak-systole. A rapid untwisting was also observed during early diastole. This work demonstrates the capability of characterizing cardiac functional response to dobutamine stimulation in the mouse heart using 2D multi-phase MR DENSE. PMID:20740659

  2. Anti-arrhythmic strategies for atrial fibrillation

    PubMed Central

    Grandi, Eleonora; Maleckar, Mary M.

    2016-01-01

    Atrial fibrillation (AF), the most common cardiac arrhythmia, is associated with increased risk of cerebrovascular stroke, and with several other pathologies, including heart failure. Current therapies for AF are targeted at reducing risk of stroke (anticoagulation) and tachycardia-induced cardiomyopathy (rate or rhythm control). Rate control, typically achieved by atrioventricular nodal blocking drugs, is often insufficient to alleviate symptoms. Rhythm control approaches include antiarrhythmic drugs, electrical cardioversion, and ablation strategies. Here, we offer several examples of how computational modeling can provide a quantitative framework for integrating multi scale data to: (a) gain insight into multi-scale mechanisms of AF; (b) identify and test pharmacological and electrical therapy and interventions; and (c) support clinical decisions. We review how modeling approaches have evolved and contributed to the research pipeline and preclinical development and discuss future directions and challenges in the field. PMID:27612549

  3. Energy expenditure in frontotemporal dementia: a behavioural and imaging study.

    PubMed

    Ahmed, Rebekah M; Landin-Romero, Ramon; Collet, Tinh-Hai; van der Klaauw, Agatha A; Devenney, Emma; Henning, Elana; Kiernan, Matthew C; Piguet, Olivier; Farooqi, I Sadaf; Hodges, John R

    2017-01-01

    SEE FINGER DOI101093/AWW312 FOR A SCIENTIFIC COMMENTARY ON THIS ARTICLE: Abnormal eating behaviour and metabolic parameters including insulin resistance, dyslipidaemia and body mass index are increasingly recognized as important components of neurodegenerative disease and may contribute to survival. It has previously been established that behavioural variant frontotemporal dementia is associated with abnormal eating behaviour characterized by increased sweet preference. In this study, it was hypothesized that behavioural variant frontotemporal dementia might also be associated with altered energy expenditure. A cohort of 19 patients with behavioural variant frontotemporal dementia, 13 with Alzheimer's disease and 16 (age- and sex-matched) healthy control subjects were studied using Actiheart devices (CamNtech) to assess resting and stressed heart rate. Actiheart devices were fitted for 7 days to measure sleeping heart rate, activity levels, and resting, active and total energy expenditure. Using high resolution structural magnetic resonance imaging the neural correlates of increased resting heart rate were investigated including cortical thickness and region of interest analyses. In behavioural variant frontotemporal dementia, resting (P = 0.001), stressed (P = 0.037) and sleeping heart rate (P = 0.038) were increased compared to control subjects, and resting heart rate (P = 0.020) compared to Alzheimer disease patients. Behavioural variant frontotemporal dementia was associated with decreased activity levels compared to controls (P = 0.002) and increased resting energy expenditure (P = 0.045) and total energy expenditure (P = 0.035). Increased resting heart rate correlated with behavioural (Cambridge Behavioural Inventory) and cognitive measures (Addenbrooke's Cognitive Examination). Increased resting heart rate in behavioural variant frontotemporal dementia correlated with atrophy involving the mesial temporal cortex, insula, and amygdala, regions previously suggested to be involved exclusively in social and emotion processing in frontotemporal dementia. These neural correlates overlap the network involved in eating behaviour in frontotemporal dementia, suggesting a complex interaction between eating behaviour, autonomic function and energy homeostasis. As such the present study suggests that increased heart rate and autonomic changes are prevalent in behavioural variant frontotemporal dementia, and are associated with changes in energy expenditure. An understanding of these changes and neural correlates may have potential relevance to disease progression and prognosis. © The Author (2016). Published by Oxford University Press on behalf of the Guarantors of Brain. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Chronotropic Incompetence and its Relation to Exercise Intolerance in Chronic Obstructive Pulmonary Disease.

    PubMed

    Liu, Hai-Jian; Guo, Jian; Zhao, Qin-Hua; Wang, Lan; Yang, Wen-Lan; He, Jing; Gong, Su-Gang; Liu, Jin-Ming

    2017-03-01

    To study the relationship between chronotropic incompetence (CI) and disease severity and to assess the effect of CI on exercise capacity in patients with chronic obstructive pulmonary disease (COPD). Arterial blood gas analysis, pulmonary function test and cardiopulmonary exercise testing were conducted in 60 patients with stable COPD and 45 healthy volunteers. CI was defined using the chronotropic response index (CRI = (peak heart rate-resting heart rate) / (220-age-resting heart rate). Based on CRI, patients with COPD were divided into the normal chronotropic group (n = 23) and CI group (n = 37). CI was present in 61.7% of the patients with COPD. Exercise capacity (peak oxygen uptake as percentage of predicted value, peak VO 2 %pred), peak heart rate and CRI were significantly lower in patients with COPD than in controls. However, resting heart rate was significantly higher than in controls. FEV 1 %pred and exercise capacity were significantly decreased in the CI group when compared with those in the normotropic group. There was significant association between CRI with FEV 1 %pred and peak VO 2 %pred. Multivariate regression analysis showed that CRI and FEV 1 %pred were independent predictors of exercise capacity in patients with COPD. A cutoff of 0.74 for the CRI showed a specificity of 94.1% in predicting patients with a peak VO 2 %pred < 60%. CRI was associated with disease severity in patients with COPD. CI may be an important parameter to reflect exercise capacity in patients with COPD. Copyright © 2017 Southern Society for Clinical Investigation. Published by Elsevier Inc. All rights reserved.

  5. Determination of Anaerobic Threshold by Heart Rate or Heart Rate Variability using Discontinuous Cycle Ergometry.

    PubMed

    Park, Sung Wook; Brenneman, Michael; Cooke, William H; Cordova, Alberto; Fogt, Donovan

    The purpose was to determine if heart rate (HR) and heart rate variability (HRV) responses would reflect anaerobic threshold (AT) using a discontinuous, incremental, cycle test. AT was determined by ventilatory threshold (VT). Cyclists (30.6±5.9y; 7 males, 8 females) completed a discontinuous cycle test consisting of 7 stages (6 min each with 3 min of rest between). Three stages were performed at power outputs (W) below those corresponding to a previously established AT, one at W corresponding to AT, and 3 at W above those corresponding to AT. The W at the intersection of the trend lines was considered each metric's "threshold". The averaged stage data for Ve, HR, and time- and frequency-domain HRV metrics were plotted versus W. The W at the "threshold" for the metrics of interest were compared using correlation analysis and paired-sample t -test. In all, several heart rate-related parameters accurately reflected AT with significant correlations (p≤0.05) were observed between AT W and HR, mean RR interval (MRR), low and high frequency spectral energy (LF and HR, respectively), high frequency peak (fHF), and HFxfHF metrics' threshold W (i.e., MRRTW, etc.). Differences in HR or HRV metric threshold W and AT for all subjects were less than 14 W. The steady state data from discontinuous protocols may allow for a true indication of steady-state physiologic stress responses and corresponding W at AT, compared to continuous protocols using 1-2 min exercise stages.

  6. Approximate Entropies for Stochastic Time Series and EKG Time Series of Patients with Epilepsy and Pseudoseizures

    NASA Astrophysics Data System (ADS)

    Vyhnalek, Brian; Zurcher, Ulrich; O'Dwyer, Rebecca; Kaufman, Miron

    2009-10-01

    A wide range of heart rate irregularities have been reported in small studies of patients with temporal lobe epilepsy [TLE]. We hypothesize that patients with TLE display cardiac dysautonomia in either a subclinical or clinical manner. In a small study, we have retrospectively identified (2003-8) two groups of patients from the epilepsy monitoring unit [EMU] at the Cleveland Clinic. No patients were diagnosed with cardiovascular morbidities. The control group consisted of patients with confirmed pseudoseizures and the experimental group had confirmed right temporal lobe epilepsy through a seizure free outcome after temporal lobectomy. We quantified the heart rate variability using the approximate entropy [ApEn]. We found similar values of the ApEn in all three states of consciousness (awake, sleep, and proceeding seizure onset). In the TLE group, there is some evidence for greater variability in the awake than in either the sleep or proceeding seizure onset. Here we present results for mathematically-generated time series: the heart rate fluctuations ξ follow the γ statistics i.e., p(ξ)=γ-1(k) ξ^k exp(-ξ). This probability function has well-known properties and its Shannon entropy can be expressed in terms of the γ-function. The parameter k allows us to generate a family of heart rate time series with different statistics. The ApEn calculated for the generated time series for different values of k mimic the properties found for the TLE and pseudoseizure group. Our results suggest that the ApEn is an effective tool to probe differences in statistics of heart rate fluctuations.

  7. Verification of the effects of Schumann frequency range electromagnetic fields on the human cardiovascular system

    NASA Astrophysics Data System (ADS)

    Tuzhilkin, D. A.; Borodin, A. S.

    2017-11-01

    The results of the study of variations in the electromagnetic background parameters of the Schumann resonator frequency range and the variability indices of the human heart period during its free activity are presented on the basis of 24-hour synchronous monitoring data. It is shown that the integral evaluation of the conjugacy of the heart rate variability indices from the Schumann resonance parameters is extremely weak. In this case, the differential evaluation of this dependence with separation into characteristic time intervals of the day, characterized by different motor activity of the subjects, becomes significantly higher. The number of volunteers whose conjugacy is characterized by a strong correlation in some cases reaches 35 percent of the sample.

  8. Exposure to bisphenol A from drinking canned beverages increases blood pressure: randomized crossover trial.

    PubMed

    Bae, Sanghyuk; Hong, Yun-Chul

    2015-02-01

    Bisphenol A (BPA) is a chemical used in plastic bottles and inner coating of beverage cans, and its exposure is almost ubiquitous. BPA has been associated with hypertension and decreased heart rate variability in the previous studies. The aim of the present study was to determine whether increased BPA exposure from consumption of canned beverage actually affects blood pressure and heart rate variability. We conducted a randomized crossover trial with noninstitutionalized adults, who were aged ≥60 years and recruited from a local community center. A total of 60 participants visited the study site 3 times, and they were provided the same beverage in 2 glass bottles, 2 cans, or 1 can and 1 glass bottle at a time. The sequence of the beverage was randomized. We then measured urinary BPA concentration, blood pressure, and heart rate variability 2 hours after the consumption of each beverage. The paired t test and mixed model were used to compare the differences. The urinary BPA concentration increased after consuming canned beverages by >1600% compared with that after consuming glass bottled beverages. Systolic blood pressure adjusted for daily variance increased by ≈4.5 mm Hg after consuming 2 canned beverages compared with that after consuming 2 glass bottled beverages, and the difference was statistically significant. The parameters of the heart rate variability did not show statistically significant differences.The present study demonstrated that consuming canned beverage and consequent increase of BPA exposure increase blood pressure acutely. © 2014 American Heart Association, Inc.

  9. Short-term effect of percutaneous recanalization of chronic total occlusions on QT dispersion and heart rate variability parameters

    PubMed Central

    Erdogan, Ercan; Akkaya, Mehmet; Bacaksız, Ahmet; Tasal, Abdurrahman; Sönmez, Osman; Asoglu, Emin; Kul, Seref; Sahın, Musa; Turfan, Murat; Vatankulu, Mehmet Akif; Göktekin, Omer

    2013-01-01

    Background QT dispersion (QTd), which is a measure of inhomogeneity of myocardial repolarization, increases following impaired myocardial perfusion. Its prolongation may provide a suitable substrate for life-threatening ventricular arrhythmias. We investigated the changes in QTd and heart rate variability (HRV) parameters after successful coronary artery revascularization in a patient with chronic total occlusions (CTO). Material/Methods This study included 139 successfully revascularized CTO patients (118 men, 21 women, mean age 58.3±9.6 years). QTd was measured from a 12-lead electrocardiogram and was defined as the difference between maximum and minimum QT interval. HRV analyses of all subjects were obtained. Frequency domain (LF: HF) and time domain (SDNN, pNN50, and rMSSD) parameters were analyzed. QT intervals were also corrected for heart rate using Bazett’s formula, and the corrected QT interval dispersion (QTcd) was then calculated. All measurements were made before and after percutaneous coronary intervention (PCI). Results Both QTd and QTcd showed significant improvement following successful revascularization of CTO (55.83±14.79 to 38.87±11.69; p<0.001 and 61.02±16.28 to 42.92±13.41; p<0.001). The revascularization of LAD (n=38), Cx (n=28) and RCA (n=73) resulted in decrease in HRV indices, including SDDN, rMSSD, and pNN50, but none of the variables reached statistical significance. Conclusions Successful revascularization of CTO may result in improvement in regional heterogeneity of myocardial repolarization, evidenced as decreased QTcd after the PCI. The revascularization in CTO lesions does not seem to have a significant impact on HRV. PMID:23969577

  10. Clonidine versus nitroglycerin infusion in laparoscopic cholecystectomy.

    PubMed

    Mishra, Manjaree; Mishra, Shashi Prakash; Mathur, Sharad Kumar

    2014-01-01

    Laparoscopic surgery offers the advantages of minimally invasive surgery; however, pneumoperitoneum and the patient's position induce pathophysiological changes that may complicate anesthetic management. We studied the effect of clonidine and nitroglycerin on heart rate and blood pressure, if any, in association with these drugs or the procedure, as well as the effect of these drugs, if any, on end-tidal carbon dioxide pressure and intraocular pressure. Sixty patients (minimum age of 20 years and maximum age of 65 years, American Society of Anesthesiologists class I or II) undergoing laparoscopic cholecystectomy were randomized into 3 groups and given an infusion of clonidine (group I), nitroglycerin (group II), or normal saline solution (group III) after induction and before creation of pneumoperitoneum. We observed and recorded the following parameters: heart rate, mean arterial blood pressure, end-tidal carbon dioxide pressure, and intraocular pressure. The mean and standard deviation of the parameters studied during the observation period were calculated for the 3 treatment groups and compared by use of analysis of variance tests. Intragroup comparison was performed with the paired t test. The critical value of P, indicating the probability of a significant difference, was taken as < .05 for comparisons. Statistically significant differences in heart rate were observed among the various groups, whereas comparisons of mean arterial pressure, intraocular pressure, and end-tidal carbon dioxide pressure showed statistically significant differences only between groups I and III and between groups II and III. We found clonidine to be more effective than nitroglycerin at preventing changes in hemodynamic parameters and intraocular pressure induced by carbon dioxide insufflation during laparoscopic cholecystectomy. It was also found not to cause hypotension severe enough to stop the infusion and warrant treatment.

  11. Clonidine Versus Nitroglycerin Infusion in Laparoscopic Cholecystectomy

    PubMed Central

    Mishra, Manjaree; Mishra, Shashi Prakash

    2014-01-01

    Background and Objectives: Laparoscopic surgery offers the advantages of minimally invasive surgery; however, pneumoperitoneum and the patient's position induce pathophysiological changes that may complicate anesthetic management. We studied the effect of clonidine and nitroglycerin on heart rate and blood pressure, if any, in association with these drugs or the procedure, as well as the effect of these drugs, if any, on end-tidal carbon dioxide pressure and intraocular pressure. Methods: Sixty patients (minimum age of 20 years and maximum age of 65 years, American Society of Anesthesiologists class I or II) undergoing laparoscopic cholecystectomy were randomized into 3 groups and given an infusion of clonidine (group I), nitroglycerin (group II), or normal saline solution (group III) after induction and before creation of pneumoperitoneum. We observed and recorded the following parameters: heart rate, mean arterial blood pressure, end-tidal carbon dioxide pressure, and intraocular pressure. The mean and standard deviation of the parameters studied during the observation period were calculated for the 3 treatment groups and compared by use of analysis of variance tests. Intragroup comparison was performed with the paired t test. The critical value of P, indicating the probability of a significant difference, was taken as < .05 for comparisons. Results: Statistically significant differences in heart rate were observed among the various groups, whereas comparisons of mean arterial pressure, intraocular pressure, and end-tidal carbon dioxide pressure showed statistically significant differences only between groups I and III and between groups II and III. Conclusion: We found clonidine to be more effective than nitroglycerin at preventing changes in hemodynamic parameters and intraocular pressure induced by carbon dioxide insufflation during laparoscopic cholecystectomy. It was also found not to cause hypotension severe enough to stop the infusion and warrant treatment. PMID:25392635

  12. Effect of alectinib on cardiac electrophysiology: results from intensive electrocardiogram monitoring from the pivotal phase II NP28761 and NP28673 studies.

    PubMed

    Morcos, Peter N; Bogman, Katrijn; Hubeaux, Stanislas; Sturm-Pellanda, Carolina; Ruf, Thorsten; Bordogna, Walter; Golding, Sophie; Zeaiter, Ali; Abt, Markus; Balas, Bogdana

    2017-03-01

    Alectinib, a central nervous system (CNS)-active ALK inhibitor, has demonstrated efficacy and safety in ALK+ non-small-cell lung cancer that has progressed following crizotinib treatment. Other ALK inhibitors have shown concentration-dependent QTc prolongation and treatment-related bradycardia. Therefore, this analysis evaluated alectinib safety in terms of electrophysiologic parameters. Intensive triplicate centrally read electrocardiogram (ECG) and matched pharmacokinetic data were collected across two alectinib single-arm trials. Analysis of QTcF included central tendency analysis [mean changes from baseline with one-sided upper 95% confidence intervals (CIs)], categorical analyses, and relationship between change in QTcF and alectinib plasma concentrations. Alectinib effects on other ECG parameters (heart rate, PR interval and QRS duration) were also evaluated. Alectinib did not cause a clinically relevant change in QTcF. The maximum mean QTcF change from baseline was 5.3 ms observed pre-dose at week 2. The upper one-sided 95% CI was <10 ms at all time points. There was no relevant relationship between change in QTcF and alectinib plasma concentrations. Alectinib treatment resulted in a generally asymptomatic exposure-dependent decrease in mean heart rate of ~11 to 13 beats per minute at week 2. No clinically relevant effects were seen on other ECG parameters. Approximately 5% of patients reported cardiac adverse events of bradycardia or sinus bradycardia; however, these were all grade 1-2. Alectinib does not prolong the QTc interval or cause changes in cardiac function to a clinically relevant extent, with the exception of a decrease in heart rate which was generally asymptomatic.

  13. Reduced heart size and increased myocardial fuel substrate oxidation in ACC2 mutant mice

    PubMed Central

    Essop, M. Faadiel; Camp, Heidi S.; Choi, Cheol Soo; Sharma, Saumya; Fryer, Ryan M.; Reinhart, Glenn A.; Guthrie, Patrick H.; Bentebibel, Assia; Gu, Zeiwei; Shulman, Gerald I.; Taegtmeyer, Heinrich; Wakil, Salih J.; Abu-Elheiga, Lutfi

    2008-01-01

    The cardiac-enriched isoform of acetyl-CoA carboxylase (ACC2) is a key regulator of mitochondrial fatty acid (FA) uptake via carnitine palmitoyltransferase 1 (CPT1). To test the hypothesis that oxidative metabolism is upregulated in hearts from animals lacking ACC2 (employing a transgenic Acc2-mutant mouse), we assessed cardiac function in vivo and determined rates of myocardial substrate oxidation ex vivo. When examined by echocardiography, there was no difference in systolic function, but left ventricular mass of the Acc2-mutant (MUT) mouse was significantly reduced (∼25%) compared with wild-types (WT). Reduced activation of the mammalian target of rapamycin (mTOR) and its downstream target p70S6K was found in MUT hearts. Exogenous oxidation rates of oleate were increased ∼22%, and, unexpectedly, exogenous glucose oxidation rates were also increased in MUT hearts. Using a hyperinsulinemic-euglycemic clamp, we found that glucose uptake in MUT hearts was increased by ∼83%. Myocardial triglyceride levels were significantly reduced in MUT vs. WT while glycogen content was the same. In parallel, transcript levels of PPARα and its target genes, pyruvate dehydrogenase kinase-4 (PDK-4), malonyl-CoA decarboxylase (MCD), and mCPT1, were downregulated in MUT mice. In summary, we report that 1) Acc2-mutant hearts exhibit a marked preference for the oxidation of both glucose and FAs coupled with greater utilization of endogenous fuel substrates (triglycerides), 2) attenuated mTOR signaling may result in reduced heart sizes observed in Acc2-mutant mice, and 3) Acc2-mutant hearts displayed normal functional parameters despite a significant decrease in size. PMID:18487439

  14. Usefulness of anaerobic threshold to peak oxygen uptake ratio to determine the severity and pathophysiological condition of chronic heart failure.

    PubMed

    Tomono, Junichi; Adachi, Hitoshi; Oshima, Shigeru; Kurabayashi, Masahiko

    2016-11-01

    Anaerobic threshold (AT) and peak oxygen uptake (V˙O 2 ) are well known as indicators of severity and prognosis of heart failure. Since these parameters are regulated by many factors, multiple organ dysfunction may occur in chronic heart failure, and these two parameters would vary among patients. However, it is not clear whether AT and peak V˙O 2 deteriorate similarly. Therefore, we planned to compare the degree of deterioration of these two parameters using a ratio of AT and peak V˙O 2 (%AT/peak), and evaluated its significance in heart failure subjects. One hundred ninety-four stable heart failure patients who had optimal medical treatment for at least 3 months were enrolled. Cardiopulmonary exercise testing, echocardiography, and blood sampling were examined within one week. Since %AT/peak varied from 50.3% to 108.5%, we divided patients into tertiles of %AT/peak [Group A, 50.1-70.0 (n=112), Group B, 70.1-90.0 (n=64), Group C, 90.1-110.0 (n=18)], and compared factors relating with skeletal muscle and heart failure among these 3 groups. In Group A, ratio of measured AT against predicted value (%AT) and measured peak V˙O 2 against predicted value (%peak V˙O 2 ) were similar (80.3±19.0% and 80.4±17.1%, respectively). Peak V˙O 2 became lower as %AT/peak increased (Group B; 65.6±14.8%, p<0.01 vs. Group A, Group C; 38.3±9.7%, p<0.01 vs. Group B). On the other hand, %AT in Group B (77.1±18.5%) was similar to Group A, and diminished in Group C (58.0±8.2%, p<0.05 vs. Group B). Peak work rate and lean body mass were smaller in Group B than those in Group A. Although, left ventricular ejection fraction and E/E' deteriorated in Group B compared with Group A, plasma B-type natriuretic peptide and estimated glomerular filtration rate stayed constant in Group B and deteriorated in Group C. %AT/peak showed negative correlation with peak V˙O 2 . In chronic heart failure, muscle weakness occurs at an early stage, and this can be evaluated using %AT/peak. Copyright © 2016 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  15. Heart rate variability and the anxious client: cardiac autonomic and behavioral associations with therapeutic alliance.

    PubMed

    Stratford, Trisha; Meara, Alan; Psychotherapy, M Gestalt; Lal, Sara

    2014-08-01

    This exploratory study was designed to investigate the link between a client's heart rate variability (HRV) and the forming of a therapeutic alliance (TA) during psychotherapy. Change in HRV is associated with many psychological and physiological situations, including cardiac mortality. Cardiac effects were evaluated during therapy in 30 symptomatically anxious clients using HRV during six weekly 1-hour therapy sessions (S1-S6). Therapeutic index (TI), a measure of TA, was evaluated using skin conductance resonance between client and therapist. The Working Alliance Inventory provides a subjective measure of TA. State and trait anxiety and mood states were also assessed. Most HRV parameters were highest during S4. The sympathovagal balance was highest in S1 but stabilized after S2. In S4, TI was linked to high HRV parameters. Overall higher anxiety levels seem to be associated to lower HRV parameters. Conversely, in S4, high HRV parameters were linked to higher mood scores. This study found that a subjective measure of TA contradicted the physiological outcome. Results suggest that physiological data collected during therapy are a more accurate barometer of TA forming. These research findings suggest a need for further research identifying physiological markers in clients with a variety of mental health disorders over long-term therapy.

  16. The impact of transportation on physiological and behavioral parameters in Wistar rats: implications for acclimatization periods.

    PubMed

    Arts, Johanna W M; Kramer, Klaas; Arndt, Saskia S; Ohl, Frauke

    2012-01-01

    Transportation of laboratory rodents unavoidably causes stress. Nevertheless, very little is known about the effects of transportation and how long it takes for the animal to recuperate. In the present study, we investigated physiological and behavioral parameters before and after transportation in both transported and nontransported animals. We took blood samples to analyze plasma corticosterone and creatine kinase, and performed physiological measurements by means of telemetry, measuring heart rate, blood pressure, and activity. Behavior was measured by means of home cage observations. This study revealed that plasma corticosterone levels increased at least up to 16 days after transportation, blood pressure and heart rate showed a lasting decrease after transportation, grooming increased, and social interactions and locomotor activity decreased after transportation. With these data we demonstrate that there is a long-lasting effect of transportation on physiological and behavioral parameters. Our results show that the stressful impact of transportation embraces all parts of the procedure, including for example the packing of the animals. Researchers must be aware of this impact and provide a sufficient acclimatization period to allow for the (re-)stabilization of parameters. Insufficient acclimatization periods endanger not only the reliability of research results but also the welfare of the animal used.

  17. Fatigue shifts and scatters heart rate variability in elite endurance athletes.

    PubMed

    Schmitt, Laurent; Regnard, Jacques; Desmarets, Maxime; Mauny, Fréderic; Mourot, Laurent; Fouillot, Jean-Pierre; Coulmy, Nicolas; Millet, Grégoire

    2013-01-01

    This longitudinal study aimed at comparing heart rate variability (HRV) in elite athletes identified either in 'fatigue' or in 'no-fatigue' state in 'real life' conditions. 57 elite Nordic-skiers were surveyed over 4 years. R-R intervals were recorded supine (SU) and standing (ST). A fatigue state was quoted with a validated questionnaire. A multilevel linear regression model was used to analyze relationships between heart rate (HR) and HRV descriptors [total spectral power (TP), power in low (LF) and high frequency (HF) ranges expressed in ms(2) and normalized units (nu)] and the status without and with fatigue. The variables not distributed normally were transformed by taking their common logarithm (log10). 172 trials were identified as in a 'fatigue' and 891 as in 'no-fatigue' state. All supine HR and HRV parameters (Beta±SE) were significantly different (P<0.0001) between 'fatigue' and 'no-fatigue': HRSU (+6.27±0.61 bpm), logTPSU (-0.36±0.04), logLFSU (-0.27±0.04), logHFSU (-0.46±0.05), logLF/HFSU (+0.19±0.03), HFSU(nu) (-9.55±1.33). Differences were also significant (P<0.0001) in standing: HRST (+8.83±0.89), logTPST (-0.28±0.03), logLFST (-0.29±0.03), logHFST (-0.32±0.04). Also, intra-individual variance of HRV parameters was larger (P<0.05) in the 'fatigue' state (logTPSU: 0.26 vs. 0.07, logLFSU: 0.28 vs. 0.11, logHFSU: 0.32 vs. 0.08, logTPST: 0.13 vs. 0.07, logLFST: 0.16 vs. 0.07, logHFST: 0.25 vs. 0.14). HRV was significantly lower in 'fatigue' vs. 'no-fatigue' but accompanied with larger intra-individual variance of HRV parameters in 'fatigue'. The broader intra-individual variance of HRV parameters might encompass different changes from no-fatigue state, possibly reflecting different fatigue-induced alterations of HRV pattern.

  18. Study of continuous blood pressure estimation based on pulse transit time, heart rate and photoplethysmography-derived hemodynamic covariates.

    PubMed

    Feng, Jingjie; Huang, Zhongyi; Zhou, Congcong; Ye, Xuesong

    2018-06-01

    It is widely recognized that pulse transit time (PTT) can track blood pressure (BP) over short periods of time, and hemodynamic covariates such as heart rate, stiffness index may also contribute to BP monitoring. In this paper, we derived a proportional relationship between BP and PPT -2 and proposed an improved method adopting hemodynamic covariates in addition to PTT for continuous BP estimation. We divided 28 subjects from the Multi-parameter Intelligent Monitoring for Intensive Care database into two groups (with/without cardiovascular diseases) and utilized a machine learning strategy based on regularized linear regression (RLR) to construct BP models with different covariates for corresponding groups. RLR was performed for individuals as the initial calibration, while recursive least square algorithm was employed for the re-calibration. The results showed that errors of BP estimation by our method stayed within the Association of Advancement of Medical Instrumentation limits (- 0.98 ± 6.00 mmHg @ SBP, 0.02 ± 4.98 mmHg @ DBP) when the calibration interval extended to 1200-beat cardiac cycles. In comparison with other two representative studies, Chen's method kept accurate (0.32 ± 6.74 mmHg @ SBP, 0.94 ± 5.37 mmHg @ DBP) using a 400-beat calibration interval, while Poon's failed (- 1.97 ± 10.59 mmHg @ SBP, 0.70 ± 4.10 mmHg @ DBP) when using a 200-beat calibration interval. With additional hemodynamic covariates utilized, our method improved the accuracy of PTT-based BP estimation, decreased the calibration frequency and had the potential for better continuous BP estimation.

  19. Spectro-Temporal Electrocardiogram Analysis for Noise-Robust Heart Rate and Heart Rate Variability Measurement

    PubMed Central

    Tobón, Diana P.; Jayaraman, Srinivasan

    2017-01-01

    The last few years has seen a proliferation of wearable electrocardiogram (ECG) devices in the market with applications in fitness tracking, patient monitoring, athletic performance assessment, stress and fatigue detection, and biometrics, to name a few. The majority of these applications rely on the computation of the heart rate (HR) and the so-called heart rate variability (HRV) index via time-, frequency-, or non-linear-domain approaches. Wearable/portable devices, however, are highly susceptible to artifacts, particularly those resultant from movement. These artifacts can hamper HR/HRV measurement, thus pose a serious threat to cardiac monitoring applications. While current solutions rely on ECG enhancement as a pre-processing step prior to HR/HRV calculation, existing artifact removal algorithms still perform poorly under extremely noisy scenarios. To overcome this limitation, we take an alternate approach and propose the use of a spectro-temporal ECG signal representation that we show separates cardiac components from artifacts. More specifically, by quantifying the rate-of-change of ECG spectral components over time, we show that heart rate estimates can be reliably obtained even in extremely noisy signals, thus bypassing the need for ECG enhancement. With such HR measurements in hands, we then propose a new noise-robust HRV index termed MD-HRV (modulation-domain HRV) computed as the standard deviation of the obtained HR values. Experiments with synthetic ECG signals corrupted at various different signal-to-noise levels, as well as recorded noisy signals show the proposed measure outperforming several HRV benchmark parameters computed post wavelet-based enhancement. These findings suggest that the proposed HR measures and derived MD-HRV metric are well-suited for ambulant cardiac monitoring applications, particularly those involving intense movement (e.g., elite athletic training). PMID:29255653

  20. Aging and CaMKII alter intracellular Ca2+ transients and heart rhythm in Drosophila melanogaster.

    PubMed

    Santalla, Manuela; Valverde, Carlos A; Harnichar, Ezequiel; Lacunza, Ezequiel; Aguilar-Fuentes, Javier; Mattiazzi, Alicia; Ferrero, Paola

    2014-01-01

    Aging is associated to disrupted contractility and rhythmicity, among other cardiovascular alterations. Drosophila melanogaster shows a pattern of aging similar to human beings and recapitulates the arrhythmogenic conditions found in the human heart. Moreover, the kinase CaMKII has been characterized as an important regulator of heart function and an arrhythmogenic molecule that participate in Ca2+ handling. Using a genetically engineered expressed Ca2+ indicator, we report changes in cardiac Ca2+ handling at two different ages. Aging prolonged relaxation, reduced spontaneous heart rate (HR) and increased the occurrence of arrhythmias, ectopic beats and asystoles. Alignment between Drosophila melanogaster and human CaMKII showed a high degree of conservation and indicates that relevant phosphorylation sites in humans are also present in the fruit fly. Inhibition of CaMKII by KN-93 (CaMKII-specific inhibitor), reduced HR without significant changes in other parameters. By contrast, overexpression of CaMKII increased HR and reduced arrhythmias. Moreover, it increased fluorescence amplitude, maximal rate of rise of fluorescence and reduced time to peak fluorescence. These results suggest that CaMKII in Drosophila melanogaster acts directly on heart function and that increasing CaMKII expression levels could be beneficial to improve contractility.

  1. Selection of entropy-measure parameters for knowledge discovery in heart rate variability data

    PubMed Central

    2014-01-01

    Background Heart rate variability is the variation of the time interval between consecutive heartbeats. Entropy is a commonly used tool to describe the regularity of data sets. Entropy functions are defined using multiple parameters, the selection of which is controversial and depends on the intended purpose. This study describes the results of tests conducted to support parameter selection, towards the goal of enabling further biomarker discovery. Methods This study deals with approximate, sample, fuzzy, and fuzzy measure entropies. All data were obtained from PhysioNet, a free-access, on-line archive of physiological signals, and represent various medical conditions. Five tests were defined and conducted to examine the influence of: varying the threshold value r (as multiples of the sample standard deviation σ, or the entropy-maximizing rChon), the data length N, the weighting factors n for fuzzy and fuzzy measure entropies, and the thresholds rF and rL for fuzzy measure entropy. The results were tested for normality using Lilliefors' composite goodness-of-fit test. Consequently, the p-value was calculated with either a two sample t-test or a Wilcoxon rank sum test. Results The first test shows a cross-over of entropy values with regard to a change of r. Thus, a clear statement that a higher entropy corresponds to a high irregularity is not possible, but is rather an indicator of differences in regularity. N should be at least 200 data points for r = 0.2 σ and should even exceed a length of 1000 for r = rChon. The results for the weighting parameters n for the fuzzy membership function show different behavior when coupled with different r values, therefore the weighting parameters have been chosen independently for the different threshold values. The tests concerning rF and rL showed that there is no optimal choice, but r = rF = rL is reasonable with r = rChon or r = 0.2σ. Conclusions Some of the tests showed a dependency of the test significance on the data at hand. Nevertheless, as the medical conditions are unknown beforehand, compromises had to be made. Optimal parameter combinations are suggested for the methods considered. Yet, due to the high number of potential parameter combinations, further investigations of entropy for heart rate variability data will be necessary. PMID:25078574

  2. Selection of entropy-measure parameters for knowledge discovery in heart rate variability data.

    PubMed

    Mayer, Christopher C; Bachler, Martin; Hörtenhuber, Matthias; Stocker, Christof; Holzinger, Andreas; Wassertheurer, Siegfried

    2014-01-01

    Heart rate variability is the variation of the time interval between consecutive heartbeats. Entropy is a commonly used tool to describe the regularity of data sets. Entropy functions are defined using multiple parameters, the selection of which is controversial and depends on the intended purpose. This study describes the results of tests conducted to support parameter selection, towards the goal of enabling further biomarker discovery. This study deals with approximate, sample, fuzzy, and fuzzy measure entropies. All data were obtained from PhysioNet, a free-access, on-line archive of physiological signals, and represent various medical conditions. Five tests were defined and conducted to examine the influence of: varying the threshold value r (as multiples of the sample standard deviation σ, or the entropy-maximizing rChon), the data length N, the weighting factors n for fuzzy and fuzzy measure entropies, and the thresholds rF and rL for fuzzy measure entropy. The results were tested for normality using Lilliefors' composite goodness-of-fit test. Consequently, the p-value was calculated with either a two sample t-test or a Wilcoxon rank sum test. The first test shows a cross-over of entropy values with regard to a change of r. Thus, a clear statement that a higher entropy corresponds to a high irregularity is not possible, but is rather an indicator of differences in regularity. N should be at least 200 data points for r = 0.2 σ and should even exceed a length of 1000 for r = rChon. The results for the weighting parameters n for the fuzzy membership function show different behavior when coupled with different r values, therefore the weighting parameters have been chosen independently for the different threshold values. The tests concerning rF and rL showed that there is no optimal choice, but r = rF = rL is reasonable with r = rChon or r = 0.2σ. Some of the tests showed a dependency of the test significance on the data at hand. Nevertheless, as the medical conditions are unknown beforehand, compromises had to be made. Optimal parameter combinations are suggested for the methods considered. Yet, due to the high number of potential parameter combinations, further investigations of entropy for heart rate variability data will be necessary.

  3. Kubios HRV--heart rate variability analysis software.

    PubMed

    Tarvainen, Mika P; Niskanen, Juha-Pekka; Lipponen, Jukka A; Ranta-Aho, Perttu O; Karjalainen, Pasi A

    2014-01-01

    Kubios HRV is an advanced and easy to use software for heart rate variability (HRV) analysis. The software supports several input data formats for electrocardiogram (ECG) data and beat-to-beat RR interval data. It includes an adaptive QRS detection algorithm and tools for artifact correction, trend removal and analysis sample selection. The software computes all the commonly used time-domain and frequency-domain HRV parameters and several nonlinear parameters. There are several adjustable analysis settings through which the analysis methods can be optimized for different data. The ECG derived respiratory frequency is also computed, which is important for reliable interpretation of the analysis results. The analysis results can be saved as an ASCII text file (easy to import into MS Excel or SPSS), Matlab MAT-file, or as a PDF report. The software is easy to use through its compact graphical user interface. The software is available free of charge for Windows and Linux operating systems at http://kubios.uef.fi. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  4. The acute (immediate) effects of reflexology on arterial compliance in healthy volunteers: A randomised study.

    PubMed

    Rollinson, Kirsty; Jones, Jenny; Scott, Norma; Megson, Ian L; Leslie, Stephen J

    2016-02-01

    Reflexology is a widely used complementary therapy. The effects of reflexology on the cardiovascular system are not well characterised. Arterial stiffness (compliance) is a marker of vascular health. This study aimed to evaluate the effects of reflexology on arterial compliance in healthy volunteers. 12 healthy volunteers (1 male; 11 female; mean age 44.8 ± 10.8 yrs) received 10 min of reflexology on each foot in a single-blind randomised study. The main outcome measures were measurements of cardiovascular parameters including heart rate, blood pressure and arterial compliance (augmentation index). Reflexology had no significant effect on heart rate, blood pressure or augmentation index (all p > 0.05). In healthy volunteers, there were no consistent changes in haemodynamic parameters with a single brief reflexology treatment. Thus from a cardiovascular point of view, reflexology (as delivered) would appear to have a limited (if any) effect on the cardiovascular system. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Recurrence quantification analysis of heart rate variability and respiratory flow series in patients on weaning trials.

    PubMed

    Arcentales, Andrés; Giraldo, Beatriz F; Caminal, Pere; Benito, Salvador; Voss, Andreas

    2011-01-01

    Autonomic nervous system regulates the behavior of cardiac and respiratory systems. Its assessment during the ventilator weaning can provide information about physio-pathological imbalances. This work proposes a non linear analysis of the complexity of the heart rate variability (HRV) and breathing duration (T(Tot)) applying recurrence plot (RP) and their interaction joint recurrence plot (JRP). A total of 131 patients on weaning trials from mechanical ventilation were analyzed: 92 patients with successful weaning (group S) and 39 patients that failed to maintain spontaneous breathing (group F). The results show that parameters as determinism (DET), average diagonal line length (L), and entropy (ENTR), are statistically significant with RP for T(Tot) series, but not with HRV. When comparing the groups with JRP, all parameters have been relevant. In all cases, mean values of recurrence quantification analysis are higher in the group S than in the group F. The main differences between groups were found on the diagonal and vertical structures of the joint recurrence plot.

  6. The multi-parameter remote measurement of rainfall

    NASA Technical Reports Server (NTRS)

    Atlas, D.; Ulbrich, C. W.; Meneghini, R.

    1982-01-01

    The measurement of rainfall by remote sensors is investigated. One parameter radar rainfall measurement is limited because both reflectivity and rain rate are dependent on at least two parameters of the drop size distribution (DSD), i.e., representative raindrop size and number concentration. A generalized rain parameter diagram is developed which includes a third distribution parameter, the breadth of the DSD, to better specify rain rate and all possible remote variables. Simulations show the improvement in accuracy attainable through the use of combinations of two and three remote measurables. The spectrum of remote measurables is reviewed. These include path integrated techniques of radiometry and of microwave and optical attenuation.

  7. The effect of heart motion on parameter bias in dynamic cardiac SPECT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ross, S.G.; Gullberg, G.T.; Huesman, R.H.

    1996-12-31

    Dynamic cardiac SPECT can be used to estimate kinetic rate parameters which describe the wash-in and wash-out of tracer activity between the blood and the myocardial tissue. These kinetic parameters can in turn be correlated to myocardial perfusion. There are, however, many physical aspects associated with dynamic SPECT which can introduce errors into the estimates. This paper describes a study which investigates the effect of heart motion on kinetic parameter estimates. Dynamic SPECT simulations are performed using a beating version of the MCAT phantom. The results demonstrate that cardiac motion has a significant effect on the blood, tissue, and backgroundmore » content of regions of interest. This in turn affects estimates of wash-in, while it has very little effect on estimates of wash-out. The effect of cardiac motion on parameter estimates appears not to be as great as effects introduced by photon noise and geometric collimator response. It is also shown that cardiac motion results in little extravascular contamination of the left ventricle blood region of interest.« less

  8. Evaluation of decontamination process of heart valve and artery tissues in European Homograft Bank (EHB): a retrospective study of 1,055 cases.

    PubMed

    Fan, Ye-Dong; Van Hoeck, Beatrice; Holovska, Vanda; Jashari, Ramadan

    2012-06-01

    To evaluate the efficiency of decontamination practice in European Homograft Bank (EHB), the data of the cardiovascular tissues received during recent 2 years were retrospectively analysed in this study. After initial assessment, the tissues were incubated in a 3-antibiotics' cocktail at 4°C for 20-48 h. The states of contamination were evaluated before and after incubation with the focus on the differences in donor type, tissue type, germ type and incubation time. Amongst 1,055 eligible tissues, 77.2% were hearts and 22.8% were arteries. 82.2% of the tissues were retrieved from the multi-organ donors (MOD), 15.4% from the recipients of heart transplantation (RHT) and 2.4% from the non-heart beating donors (NHBD). The initial contamination rate was 27.4% with a significantly higher incidence in arteries. The RHT tissues had the lowest contamination rate comparing to that of MOD and NHBD. Staphylococcus species was the major source of contamination. After antibiotic incubation, 76.8% of the contaminated tissues were disinfected, which was significantly higher for the hearts than the arteries. The RHT tissues had the highest decontamination rate than that of MOD and NHBD tissues. Propionibacterium acnes was detected in 48.1% of the remaining contaminated cases. The average incubation time of the Propionibacterium-positive tissues was significantly shorter than that of decontaminated tissues. In conclusion, the current decontamination protocol of EHB is sufficient for most of the initially contaminated bacteria, whereas it is inadequate for Propionibacterium acnes. This may be related to the slow-growing nature of this bacterium and thereby the relative shorter antibiotic incubation time.

  9. HRV Influence During Renal Transplantation Procedure on Long-Term Mortality.

    PubMed

    Biernawska, J; Kotfis, K; Kaczmarczyk, M; Błaszczyk, W; Barnik, E; Żukowski, M

    2016-06-01

    The autonomic nervous system plays an important role in heart function regulation. One of the most acknowledged methods for noninvasive measurement of autonomic system activity is to determine heart rate variability (HRV). Reduced HRV parameters-heart rate rigidity/stiffness-are an independent prognostic factor of sudden cardiac death risk because of arrhythmia. Renal transplantation is an important factor in HRV changes because of hemodynamic and ion disturbances. The main purpose of this study was to determine the influence of HRV disturbances during renal transplantation procedures on long-term mortality in patients with chronic kidney disease. A prospective observation study was performed in the Department of Anesthesiology, Intensive Care, and Acute Poisoning, Pomeranian Medical University, Szczecin, Poland. There were 75 patients (mean age, 47 ± 12 years; 42 men) treated with renal transplantation between 2008 and 2010. Patients were monitored with electrocardiographic tracing with the use of 7 electrodes in position type B. The final stage of analysis was to determine the possible relationship between HRV parameters during the perioperative period and the number of deaths within a 5-year follow-up. HRV parameters during the perioperative period of renal transplantation and the number of deaths within a 5-year follow-up, measured by use of the Holter method, did not differ among patients in the studied population. HRV is a noninvasive and confirmed tool used for the evaluation of autonomic function and mortality risk in patients with end-stage renal disease. HRV parameters recorded in the perioperative period are not optimal stratification tools for estimating the risk of cardiac deaths in patients with end-stage renal disease. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Measuring the human psychophysiological conditions without contact

    NASA Astrophysics Data System (ADS)

    Scalise, L.; Casacanditella, L.; Cosoli, G.

    2017-08-01

    Heart Rate Variability, HRV, studies the variations of cardiac rhythm caused by the autonomic regulation. HRV analysis can be applied to the study of the effects of mental or physical stressors on the psychophysiological conditions. The present work is a pilot study performed on a 23-year-old healthy subject. The measurement of HRV was performed by means of two sensors, that is an electrocardiograph and a Laser Doppler Vibrometer, which is a non-contact device able to detect the skin vibrations related to the cardiac activity. The present study aims to evaluate the effects of a physical task on HRV parameters (in both time and frequency domain), and consequently on the autonomic regulation, and the capability of Laser Doppler Vibrometry in correctly detecting the effects of stress on the Heart Variability. The results show a significant reduction of HRV parameters caused by the execution of the physical task (i.e. variations of 25-40% for parameters in time domain, also higher in frequency domain); this is consistent with the fact that stress causes a reduced capability of the organism in varying the Heart Rate (and, consequently, a limited HRV). LDV was able to correctly detect this phenomenon in the time domain, while the parameters in the frequency domain show significant deviations with respect to the gold standard technique (i.e. ECG). This may be due to the movement artefacts that have consistently modified the shape of the vibration signal measured by means of LDV, after having performed the physical task. In the future, in order to avoid this drawback, the LDV technique could be used to evaluate the effects of a mental task on HRV signals (i.e. the evaluation of mental stress).

  11. Relationship between Autonomic Markers of Heart Rate and Subjective Indicators of Recovery Status in Male, Elite Badminton Players.

    PubMed

    Bisschoff, Christo A; Coetzee, Ben; Esco, Michael R

    2016-12-01

    The primary aim of the study was to determine if heart rate variability (HRV), and heart rate recovery (HRR) are related to several subjective indicators of recovery status (muscle soreness, hydration status, sleep quality and quantity as well as pre-competition mood states) for different match periods in male, elite, African, singles badminton players. HRV and HRR were measured in twenty-two badminton players before (pre-match), during (in-match), after (post-match) and during rest periods (in-match rest) of 46 national and international matches. Muscle soreness, hydration status, and sleep quality and quantity were measured on a daily basis whereas mood states were measured just before each match via questionnaires. Prior to each match warm-up, players were fitted with a Fix Polar Heart Rate Transmitter Belt to record heart rate every second during each match and HRR during service breaks and after matches. Kubios HRV software was used for final HRV analyses from the series of R-R-intervals. A strong, significant canonical correlation (Rc = 0.96, p = 0.014) was found between HRV, HRR and subjective indicators of recovery status for the in-match period, but only strong, non-significant relationships were observed for pre-match (Rc = 0.98, p = 0.626) and post-match periods (Rc = 0.98, p = 0.085) and a low non-significant relationship (Rc = 0.69, p = 0.258) for the in-match rest period. Canonical functions accounted for between 47.89% and 96.43% of the total variation between the two canonical variants. Results further revealed that Ln-HFnu, the energy index and vigour were the most prominent variables in the relationship between the autonomic markers of heart rate and recovery-related variables. In conclusion, this study proved that subjective indicators of recovery status influence HRV and HRR measures obtained in a competitive badminton environment and should therefore be incorporated in protocols that evaluate these ANS-related parameters.

  12. Influence of transvaginal ultrasound-guided follicular punctures in the mare on heart rate, respiratory rate, facial expression changes, and salivary cortisol as pain scoring.

    PubMed

    Diego, Rodrigo; Douet, Cécile; Reigner, Fabrice; Blard, Thierry; Cognié, Juliette; Deleuze, Stefan; Goudet, Ghylène

    2016-10-15

    Transvaginal ultrasound-guided follicular punctures are widely used in the mare for diagnosis, research, and commercial applications. The objective of our study was to determine their influence on pain, stress, and well-being in the mare, by evaluating heart rate, breath rate, facial expression changes, and salivary cortisol before, during, and after puncture. For this experiment, 21 pony mares were used. Transvaginal ultrasound-guided aspirations were performed on 11 mares. After injections for sedation, analgesia, and antispasmodia, the follicles from both ovaries were aspirated with a needle introduced through the vagina wall into the ovary. In the control group, 10 mares underwent similar treatments and injections, but no follicular aspiration. Along the session, heart rate and breath rate were evaluated by a trained veterinarian, ears position, eyelid closure, and contraction of facial muscles were evaluated, and salivary samples were taken for evaluation of cortisol concentration. A significant relaxation was observed after sedative injection in the punctured and control mares, according to ear position, eyelid closure, and contraction of facial muscles, but no difference between punctured and control animals was recorded. No significant modification of salivary cortisol concentration during puncture and no difference between punctured and control mares at any time were observed. No significant modification of the breath rate was observed along the procedure for the punctured and the control mares. Heart rate increased significantly but transiently when the needle was introduced in the ovary and was significantly higher at that time for the punctured mares than that for control mares. None of the other investigated parameters were affected at that time, suggesting discomfort is minimal and transient. Improving analgesia, e.g., through a multimodal approach, during that possibly more sensitive step could be recommended. The evaluation of facial expression changes and heart rate is easy-to-use and accurate tools to evaluate pain and well-being of the mare. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. The effects of short-term relaxation therapy on indices of heart rate variability and blood pressure in young adults.

    PubMed

    Pal, Gopal Krushna; Ganesh, Venkata; Karthik, Shanmugavel; Nanda, Nivedita; Pal, Pravati

    2014-01-01

    Assessment of short-term practice of relaxation therapy on autonomic and cardiovascular functions in first-year medical students. Case-control, interventional study. Medical college laboratory. Sixty-seven medical students, divided into two groups: study group (n = 35) and control group (n = 32). Study group subjects practiced relaxation therapy (shavasana with a soothing background music) daily 1 hour for 6 weeks. Control group did not practice relaxation techniques. Cardiovascular parameters and spectral indices of heart rate variability (HRV) were recorded before and after the 6-week practice of relaxation therapy. The data between the groups and the data before and after practice of relaxation techniques were analyzed by one-way analysis of variance and Student t-test. In the study group, prediction of low-frequency to high-frequency ratio (LF-HF) of HRV, the marker of sympathovagal balance, to blood pressure (BP) status was assessed by logistic regression. In the study group, there was significant reduction in heart rate (p = .0001), systolic (p = .0010) and diastolic (p = .0021) pressure, and rate pressure product (p < .0001), and improvement in HRV indices, following 6 weeks of relaxation therapy. As determined by regression model, prediction of LF-HF to BP status was more significant (odds ratio, 2.7; p = .009) after practice of relaxation therapy. There was no significant alteration in these parameters in control subjects. Short-term practice of relaxation therapy can improve autonomic balance and promote cardiovascular health of medical students. Sympathovagal balance is directly linked to BP status in these individuals.

  14. Video pulse rate variability analysis in stationary and motion conditions.

    PubMed

    Melchor Rodríguez, Angel; Ramos-Castro, J

    2018-01-29

    In the last few years, some studies have measured heart rate (HR) or heart rate variability (HRV) parameters using a video camera. This technique focuses on the measurement of the small changes in skin colour caused by blood perfusion. To date, most of these works have obtained HRV parameters in stationary conditions, and there are practically no studies that obtain these parameters in motion scenarios and by conducting an in-depth statistical analysis. In this study, a video pulse rate variability (PRV) analysis is conducted by measuring the pulse-to-pulse (PP) intervals in stationary and motion conditions. Firstly, given the importance of the sampling rate in a PRV analysis and the low frame rate of commercial cameras, we carried out an analysis of two models to evaluate their performance in the measurements. We propose a selective tracking method using the Viola-Jones and KLT algorithms, with the aim of carrying out a robust video PRV analysis in stationary and motion conditions. Data and results of the proposed method are contrasted with those reported in the state of the art. The webcam achieved better results in the performance analysis of video cameras. In stationary conditions, high correlation values were obtained in PRV parameters with results above 0.9. The PP time series achieved an RMSE (mean ± standard deviation) of 19.45 ± 5.52 ms (1.70 ± 0.75 bpm). In the motion analysis, most of the PRV parameters also achieved good correlation results, but with lower values as regards stationary conditions. The PP time series presented an RMSE of 21.56 ± 6.41 ms (1.79 ± 0.63 bpm). The statistical analysis showed good agreement between the reference system and the proposed method. In stationary conditions, the results of PRV parameters were improved by our method in comparison with data reported in related works. An overall comparative analysis of PRV parameters in motion conditions was more limited due to the lack of studies or studies containing insufficient data analysis. Based on the results, the proposed method could provide a low-cost, contactless and reliable alternative for measuring HR or PRV parameters in non-clinical environments.

  15. Navigating the fifth dimension: new concepts in interactive multimodality and multidimensional image navigation

    NASA Astrophysics Data System (ADS)

    Ratib, Osman; Rosset, Antoine; Dahlbom, Magnus; Czernin, Johannes

    2005-04-01

    Display and interpretation of multi dimensional data obtained from the combination of 3D data acquired from different modalities (such as PET-CT) require complex software tools allowing the user to navigate and modify the different image parameters. With faster scanners it is now possible to acquire dynamic images of a beating heart or the transit of a contrast agent adding a fifth dimension to the data. We developed a DICOM-compliant software for real time navigation in very large sets of 5 dimensional data based on an intuitive multidimensional jog-wheel widely used by the video-editing industry. The software, provided under open source licensing, allows interactive, single-handed, navigation through 3D images while adjusting blending of image modalities, image contrast and intensity and the rate of cine display of dynamic images. In this study we focused our effort on the user interface and means for interactively navigating in these large data sets while easily and rapidly changing multiple parameters such as image position, contrast, intensity, blending of colors, magnification etc. Conventional mouse-driven user interface requiring the user to manipulate cursors and sliders on the screen are too cumbersome and slow. We evaluated several hardware devices and identified a category of multipurpose jogwheel device that is used in the video-editing industry that is particularly suitable for rapidly navigating in five dimensions while adjusting several display parameters interactively. The application of this tool will be demonstrated in cardiac PET-CT imaging and functional cardiac MRI studies.

  16. Effects of changing heart rate on electrophysiological and hemodynamic function in the dog.

    PubMed

    Hamlin, Robert L; Nakayama, Tomohiro; Nakayama, Hitomi; Carnes, Cynthia A

    2003-03-14

    Cardiovascular parameters were measured in dogs after RR interval was changed from 0.25 s to 1.2 s with atropine and graded doses of zatebradine, an I(f)-channel blocker. Left ventricular (LV) pre-ejection period (PEP), systemic vascular resistance, tau (an estimate of myocardial stiffness), PQ, QTc, dLVP/dt(max) and dLVP/dt(min), aortic pressure, and right atrial pressure did not change when each parameter was plotted against RR interval (r(2)'s < or = 0.5). LV end-diastolic pressure, stroke volume index, LV ejection time (ET), and QT all increased either linearly or curvilinearly as RR interval prolonged. Cardiac output index and PEP/ET decreased curvilinearly. When heart rate (HR) was fixed by pacing, and graded doses of zatebradine were given, changes in cardiovascular function were minimal. Thus zatebradine affects cardiovascular function principally by changing HR and not by affecting function directly. This study provides data on the effects of changing HR, alone, on cardiovascular parameters measured frequently during pharmacological and toxicological studies. It should prove useful when physiological variables, including HR, change, and there is need to know what change in HR, alone, contributes.

  17. Novel insights in cough and breathing patterns of patients with idiopathic pulmonary fibrosis performing repeated 24-hour-respiratory polygraphies.

    PubMed

    Schertel, Anke; Funke-Chambour, Manuela; Geiser, Thomas; Brill, Anne-Kathrin

    2017-11-13

    The main symptoms of patients with idiopathic pulmonary fibrosis (IPF) are cough and dyspnea. IPF leads to a restrictive lung disorder impacting daytime and nocturnal breathing patterns. In this pilot study we assessed the course of day- and nighttime respiration, oxygenation, and cough over a period of 8 months as well as differences between wakefulness and sleep in IPF patients. Repetitive 24-h respiratory polygraphies (RP) and pulmonary function tests were performed at baseline and after 3, 4, 7 and 8 months. Cough-index, oxygenation parameters (SpO2, time with SpO2 < 90%, desaturation index), respiratory rate and heart rate were assessed for differences between wakefulness and sleep. The first and the last RP were compared to identify changes of these parameters over time. Statistical analyses were performed with Wilcoxon signed rank tests. Nine IPF patients (8 male, median age 67 years (IQR 60, 77) with 37 valid 24-h RPs were included. Eight patients (88.9%) received antifibrotic treatment. Cough was more prevalent during wakefulness with a median cough-index of 14.8/h (IQR 10.9, 16.8) and 1.6/h (IQR 1.3-2.8) during sleep, p = 0.0039. Oxygenation parameters showed no difference, while respiratory- and heart rate were significantly higher during wakefulness. Despite stable pulmonary function tests over 8 months, the initially elevated respiratory rate increased further during wakefulness (baseline RR median 25.7/min (IQR 19.8, 26.6) vs. RR median 32.2/min (IQR 26.5, 40.9) at follow-up, p = 0.0273). The other respiratory parameters remained stable over time. Cough in IPF patients is more prevalent during wakefulness than during sleep. Further studies with a larger sample size and longer a follow-up period are needed to evaluate the role of the respiratory rate during wakefulness as a potential clinical follow up parameter in IPF.

  18. Modest weight loss in moderately overweight postmenopausal women improves heart rate variability.

    PubMed

    Mouridsen, Mette Rauhe; Bendsen, Nathalie Tommerup; Astrup, Arne; Haugaard, Steen Bendix; Binici, Zeynep; Sajadieh, Ahmad

    2013-08-01

    To evaluate the effects of weight loss on heart rate (HR) and heart rate variability (HRV) parameters in overweight postmenopausal women. Forty-nine overweight postmenopausal women with an average body mass index of 28.8 ± 1.9 kg/m(2) underwent a 12-week dietary weight-loss programme. Accepted variables for characterization of HRV were analysed before and after the weight loss by 24-h ambulatory ECG monitoring; mean and standard deviation for the time between normal-to-normal complexes (MeanNN and SDNN, respectively), and the mean of standard deviations of normal-to-normal intervals for each 5-min period (SDNNindex). Baseline body fat mass (FM%) and changes in body composition was determined by dual X-ray absorptiometry. Before and after the weight-loss period, total abdominal fat, intra-abdominal fat (IAAT), and subcutaneous abdominal fat (SCAT) were measured by single-slice MRI at L3. The weight loss of 3.9 ± 2.0 kg was accompanied by an improvement of HRV. SDNN increased by 9.2% (p = 0.003) and SDNNindex increased by 11.4% (p = 0.0003). MeanNN increased by 2.4%, reflecting a decrease in mean heart rate from 74.1 to 72.3 beats/min (p = 0.033). Systolic blood pressure (SBP) decreased by 2.7%, total cholesterol by 5.1% and high-sensitivity C-reactive protein (hsCRP) by 15.8% (p = 0.002). Improvements in SDNN and cholesterol were correlated with weight loss (r = -0.329, p = 0.024 and r = 0.327, p = 0.020, respectively) but changes in HR, SBP, and hsCRP were not. IAAT and the IAAT/SCAT-ratio were found to be negatively associated with HRV parameters but changes in body composition were not associated with changes in HRV. The observed improvement of HRV seems to be facilitated by weight loss. IAAT and the IAAT/SCAT ratio were found to be associated with low HRV.

  19. Effects of music on psychophysiological responses and opioid dosage in patients undergoing total knee replacement surgery.

    PubMed

    Chen, Hsin-Ji; Chen, Tsung-Ying; Huang, Chiung-Yu; Hsieh, Yuan-Mei; Lai, Hui-Ling

    2015-10-01

    The present authors examined the effects of listening to music on psychophysiological parameters (blood pressure, heart rate, and respiratory rate) during preoperative and postoperative days and determined whether listening to music could lower pain intensity and opioid dosage during postoperative days in patients who underwent total knee replacements. This was a two group repeated measures design for 30 subjects aged 53-85 years who were scheduled for total knee replacement. Subjects were randomly assigned to either a music group or a control group. Psychophysiological parameters were obtained from patients' monitors. A visual analog scale was used to assess postoperative pain. Opioid dosage was recorded and converted to standardized units. Mann-Whitney U-test and generalized estimating equation analysis were used to compare groups. Respiratory rates while in the surgical waiting area were lower for the music group than for the control group (P = 0.02). There was no significant difference between these groups for blood pressure, heart rate, pain intensity, or opioid dosage. However, a within-group comparison showed that systolic blood pressure in the music group was significantly and consistently decreased during postoperative recovery (Wald = 9.21, P = 0.007). These results suggest that listening to music stabilized systolic blood pressure in patients during postoperative recovery. However, the effects of music on psychophysiological parameters, pain intensity, and opioid dosage in a surgical setting require further research. © 2015 The Authors. Japan Journal of Nursing Science © 2015 Japan Academy of Nursing Science.

  20. Multi-Ethnic Study of Atherosclerosis (MESA)

    ClinicalTrials.gov

    2016-07-28

    Atherosclerosis; Cardiovascular Diseases; Heart Diseases; Coronary Artery Disease; Coronary Disease; Stroke; Myocardial Infarction; Heart Failure; Diabetes Mellitus, Type 2; Hypertension; Diabetes Mellitus

  1. Cardiorespiratory parameters and their relation with gestational age and level of oral feeding skills in preterm infants.

    PubMed

    Yamamoto, Raquel Coube de Carvalho; Prade, Leila Sauer; Berwig, Luana Cristina; Weinmann, Angela Regina Maciel; Keske-Soares, Márcia

    2016-01-01

    To correlate cardiorespiratory parameters with gestational age and level of oral feeding skills in the first oral feeding in preterm infants. Study participants were 37 clinically stable preterm infants. Cardiorespiratory rate was assessed before and after introduction of oral feeding. The newborns were divided into three strata according to gestational age at birth. Oral skill was classified into four levels: I - low oral skill and low resistance to feeding; II - low oral skill and high resistance to feeding; III - high oral skill and low resistance to feeding; IV - high oral skill and high resistance to feeding. No difference was observed in heart and respiratory rate between the strata of gestational age at birth and between the levels of oral skill. Comparison between pre- and post-cardiorespiratory rates within each level of oral skill and stratum of gestational age showed difference between heart rate in the strata of gestational ages of 30 to 33 weeks and of 34 to 36 weeks, as well as between oral skill of levels I, II, and IV. With regard to the comparison between pre- and post- respiratory rates, difference was found in the oral skill of level I. Differences were observed between pre- and post-prandial cardiorespiratory rates regarding the first oral feeding, as well as between strata of gestational age at birth and levels of oral feeding skills.

  2. [Upper extremity kinetics and energy expenditure during walker-assisted gait in children with cerebral palsy].

    PubMed

    Konop, Katherine A; Strifling, Kelly M B; Wang, Mei; Cao, Kevin; Eastwood, Daniel; Jackson, Scott; Ackman, Jeffrey; Altiok, Haluk; Schwab, Jeffrey; Harris, Gerald F

    2009-01-01

    We evaluated the relationships between upper extremity (UE) kinetics and the energy expenditure index during anterior and posterior walker-assisted gait in children with spastic diplegic cerebral palsy (CP). Ten children (3 boys, 7 girls; mean age 12.1 years; range 8 to 18 years) with spastic diplegic CP, who ambulated with a walker underwent gait analyses that included UE kinematics and kinetics. Upper extremity kinetics were obtained using instrumented walker handles. Energy expenditure index was obtained using the heart rate method (EEIHR) by subtracting resting heart rate from walking heart rate, and dividing by the walking speed. Correlations were sought between the kinetic variables and the EEIHR and temporal and stride parameters. In general, anterior walker use was associated with a higher EEIHR. Several kinetic variables correlated well with temporal and stride parameters, as well as the EEIHR. All of the significant correlations (r>0.80; p<0.005) occurred during anterior walker use and involved joint reaction forces (JRF) rather than moments. Some variables showed multiple strong correlations during anterior walker use, including the medial JRF in the wrist, the posterior JRF in the elbow, and the inferior and superior JRFs in the shoulder. The observed correlations may indicate a relationship between the force used to advance the body forward within the walker frame and an increased EEIHR. More work is needed to refine the correlations, and to explore relationships with other variables, including the joint kinematics.

  3. Diagnosis of major depressive disorder by combining multimodal information from heart rate dynamics and serum proteomics using machine-learning algorithm.

    PubMed

    Kim, Eun Young; Lee, Min Young; Kim, Se Hyun; Ha, Kyooseob; Kim, Kwang Pyo; Ahn, Yong Min

    2017-06-02

    Major depressive disorder (MDD) is a systemic and multifactorial disorder that involves abnormalities in multiple biochemical pathways and the autonomic nervous system. This study applied a machine-learning method to classify MDD and control groups by incorporating data from serum proteomic analysis and heart rate variability (HRV) analysis for the identification of novel peripheral biomarkers. The study subjects consisted of 25 drug-free female MDD patients and 25 age- and sex-matched healthy controls. First, quantitative serum proteome profiles were analyzed by liquid chromatography-tandem mass spectrometry using pooled serum samples from 10 patients and 10 controls. Next, candidate proteins were quantified with multiple reaction monitoring (MRM) in 50 subjects. We also analyzed 22 linear and nonlinear HRV parameters in 50 subjects. Finally, we identified a combined biomarker panel consisting of proteins and HRV indexes using a support vector machine with recursive feature elimination. A separation between MDD and control groups was achieved using five parameters (apolipoprotein B, group-specific component, ceruloplasmin, RMSSD, and SampEn) at 80.1% classification accuracy. A combination of HRV and proteomic data achieved better classification accuracy. A high classification accuracy can be achieved by combining multimodal information from heart rate dynamics and serum proteomics in MDD. Our approach can be helpful for accurate clinical diagnosis of MDD. Further studies using larger, independent cohorts are needed to verify the role of these candidate biomarkers for MDD diagnosis. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Assessment of general movements and heart rate variability in prediction of neurodevelopmental outcome in preterm infants.

    PubMed

    Dimitrijević, Lidija; Bjelaković, Bojko; Čolović, Hristina; Mikov, Aleksandra; Živković, Vesna; Kocić, Mirjana; Lukić, Stevo

    2016-08-01

    Adverse neurologic outcome in preterm infants could be associated with abnormal heart rate (HR) characteristics as well as with abnormal general movements (GMs) in the 1st month of life. To demonstrate to what extent GMs assessment can predict neurological outcome in preterm infants in our clinical setting; and to assess the clinical usefulness of time-domain indices of heart rate variability (HRV) in improving predictive value of poor repertoire (PR) GMs in writhing period. Qualitative assessment of GMs at 1 and 3 months corrected age; 24h electrocardiography (ECG) recordings and analyzing HRV at 1 month corrected age. Seventy nine premature infants at risk of neurodevelopmental impairments were included prospectively. Neurodevelopmental outcome was assessed at the age of 2 years corrected. Children were classified as having normal neurodevelopmental status, minor neurologic dysfunction (MND), or cerebral palsy (CP). We found that GMs in writhing period (1 month corrected age) predicted CP at 2 years with sensitivity of 100%, and specificity of 72.1%. Our results demonstrated the excellent predictive value of cramped synchronized (CS) GMs, but not of PR pattern. Analyzing separately a group of infants with PR GMs we found significantly lower values of HRV parameters in infants who later developed CP or MND vs. infants with PR GMs who had normal outcome. The quality of GMs was predictive for neurodevelopmental outcome at 2 years. Prediction of PR GMs was significantly enhanced with analyzing HRV parameters. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. Heart rate detection from single-foot plantar bioimpedance measurements in a weighing scale.

    PubMed

    Diaz, Delia H; Casas, Oscar; Pallas-Areny, Ramon

    2010-01-01

    Electronic bathroom scales are an easy-to-use, affordable mean to measure physiological parameters in addition to body weight. They have been proposed to obtain the ballistocardiogram (BCG) and derive from it the heart rate, cardiac output and systolic blood pressure. Therefore, weighing scales may suit intermittent monitoring in e-health and patient screening. Scales intended for bioelectrical impedance analysis (BIA) have also been proposed to estimate the heart rate by amplifying the pulsatile impedance component superimposed on the basal impedance. However, electronic weighing scales cannot easily obtain the BCG from people that have a single leg neither are bioimpedance measurements between both feet recommended for people wearing a pacemaker or other electronic implants, neither for pregnant women. We propose a method to detect the heart rate (HR) from bioimpedance measured in a single foot while standing on an bathroom weighting scale intended for BIA. The electrodes built in the weighing scale are used to apply a 50 kHz voltage between the outer electrode pair and to measure the drop in voltage across the inner electrode pair. The agreement with the HR simultaneously obtained from the ECG is excellent. We have also compared the drop in voltage across the waist and the thorax with that obtained when measuring bioimpedance between both feet to compare the possible risk of the proposed method to that of existing BIA scales.

  6. In Sync: The Effect of Physiology Feedback on the Match between Heart Rate and Self-Reported Stress.

    PubMed

    van Dijk, Elisabeth T; Westerink, Joyce H D M; Beute, Femke; IJsselsteijn, Wijnand A

    2015-01-01

    Over the past years self-tracking of physiological parameters has become increasingly common: more and more people are keeping track of aspects of their physiological state (e.g., heart rate, blood sugar, and blood pressure). To shed light on the possible effects of self-tracking of physiology, a study was conducted to test whether physiology feedback has acute effects on self-reported stress and the extent to which self-reported stress corresponds to physiological stress. In this study, participants executed several short tasks, while they were either shown visual feedback about their heart rate or not. Results show that self-reported stress is more in sync with heart rate for participants who received physiology feedback. Interactions between two personality factors (neuroticism and anxiety sensitivity) and feedback on the level of self-reported stress were found, indicating that while physiology feedback may be beneficial for individuals high in neuroticism, it may be detrimental for those high in anxiety sensitivity. Additional work is needed to establish how the results of this study may extend beyond immediate effects in a controlled lab setting, but our results do provide a first indication of how self-tracking of physiology may lead to better body awareness and how personality characteristics can help us predict which individuals are most likely to benefit from self-tracking of physiology.

  7. In Sync: The Effect of Physiology Feedback on the Match between Heart Rate and Self-Reported Stress

    PubMed Central

    van Dijk, Elisabeth T.; Westerink, Joyce H. D. M.; Beute, Femke; IJsselsteijn, Wijnand A.

    2015-01-01

    Over the past years self-tracking of physiological parameters has become increasingly common: more and more people are keeping track of aspects of their physiological state (e.g., heart rate, blood sugar, and blood pressure). To shed light on the possible effects of self-tracking of physiology, a study was conducted to test whether physiology feedback has acute effects on self-reported stress and the extent to which self-reported stress corresponds to physiological stress. In this study, participants executed several short tasks, while they were either shown visual feedback about their heart rate or not. Results show that self-reported stress is more in sync with heart rate for participants who received physiology feedback. Interactions between two personality factors (neuroticism and anxiety sensitivity) and feedback on the level of self-reported stress were found, indicating that while physiology feedback may be beneficial for individuals high in neuroticism, it may be detrimental for those high in anxiety sensitivity. Additional work is needed to establish how the results of this study may extend beyond immediate effects in a controlled lab setting, but our results do provide a first indication of how self-tracking of physiology may lead to better body awareness and how personality characteristics can help us predict which individuals are most likely to benefit from self-tracking of physiology. PMID:26146611

  8. High psychosis liability is associated with altered autonomic balance during exposure to Virtual Reality social stressors.

    PubMed

    Counotte, Jacqueline; Pot-Kolder, Roos; van Roon, Arie M; Hoskam, Olivier; van der Gaag, Mark; Veling, Wim

    2017-06-01

    Social stressors are associated with an increased risk of psychosis. Stress sensitisation is thought to be an underlying mechanism and may be reflected in an altered autonomic stress response. Using an experimental Virtual Reality design, the autonomic stress response to social stressors was examined in participants with different liability to psychosis. Fifty-five patients with recent onset psychotic disorder, 20 patients at ultra-high risk for psychosis, 42 siblings of patients with psychosis and 53 controls were exposed to social stressors (crowdedness, ethnic minority status and hostility) in a Virtual Reality environment. Heart rate variability parameters and skin conductance levels were measured at baseline and during Virtual Reality experiments. High psychosis liability groups had significantly increased heart rate and decreased heart rate variability compared to low liability groups both at baseline and during Virtual Reality experiments. Both low frequency (LF) and high frequency (HF) power were reduced, while the LF/HF ratio was similar between groups. The number of virtual social stressors significantly affected heart rate, HF, LF/HF and skin conductance level. There was no interaction between psychosis liability and amount of virtual social stress. High liability to psychosis is associated with decreased parasympathetic activity in virtual social environments, which reflects generally high levels of arousal, rather than increased autonomic reactivity to social stressors. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Tactile stimulation during neonatal transition and its effect on vital parameters in neonates during neonatal transition.

    PubMed

    Baik-Schneditz, Nariae; Urlesberger, Berndt; Schwaberger, Bernhard; Mileder, Lukas; Schmölzer, Georg; Avian, Alexander; Pichler, Gerhard

    2018-06-01

    This study analysed tactile stimulation during neonatal transition and resuscitation in preterm and term neonates born by Caesarean delivery. It examined the frequency, location and body region, duration and possible effects of stimulation on heart rate and arterial oxygen saturation (SpO 2 ). Two independent investigators analysed video recordings of tactile stimulation on term and preterm neonates during neonatal transition from January 2012 to December 2014. They were recorded during a prospective observational study and randomised controlled trial at a tertiary centre, the Medical University of Graz, Austria. SpO 2 and heart rate were continuously recorded. Data on the frequency, body region and duration of stimulation were collected. To investigate the possible effects of stimulation, SpO 2 and heart rate were compared before and after stimulation. Term infants received tactile stimulation more than once, and it tended to start later, last longer and be applied in more locations than in preterm infants. Only preterm infants showed a significant increase in SpO 2 after stimulation and heart rates did not show any significant changes in either group. Tactile stimulation was applied in different ways to preterm and term infants during neonatal transition and SpO 2 showed a significant increase in preterm infants. ©2018 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  10. Changes of Heart Rate Variability during Methylphenidate Treatment in Attention-Deficit Hyperactivity Disorder Children: A 12-Week Prospective Study.

    PubMed

    Kim, Hayeon Jennifer; Yang, Jaewon; Lee, Moon Soo

    2015-09-01

    The aim of this study was to clarify the relationship between the autonomic nervous system and attention deficit hyperactivity disorder (ADHD) rating scales and to evaluate the usefulness of heart rate variability (HRV) as a psychophysiological biomarker for ADHD. Subjects were recruited from outpatients in the Department of Child and Adolescent Psychiatry at the Korea University Medical Center from August 2007 to December 2010. Subjects received methylphenidate. Time- and frequency-domain analyses of HRV, the Korean ADHD rating scale (K-ARS), and computerized ADHD diagnostic system were evaluated before treatment. After a 12-week period of medication administration, we repeated the HRV measurements and K-ARS rating. Eighty-six subjects were initially enrolled and 37 participants completed the 12-week treatment and HRV measurements subsequent to the treatment. Significant correlations were found between the K-ARS inattention score and some HRV parameters. All of the HRV parameters, except the standard deviations of the normal-to-normal interval, very low frequency, and low frequency to high frequency, showed a significant positive correlation between baseline and endpoint measures in completers. High frequency (HF) and the square root of the mean squared differences of successive normal-to-normal intervals (RMSSD), which are related to parasympathetic vagal tone, showed significant decreases from baseline to endpoint. The HRV test was shown to be reproducible. The decrease in HF and RMSSD suggests that parasympathetic dominance in ADHD can be altered by methylphenidate treatment. It also shows the possibility that HRV parameters can be used as psychophysiological markers in the treatment of ADHD.

  11. Monitoring of electric-cardio signals based on DSP

    NASA Astrophysics Data System (ADS)

    Yan, Yi-xin; Sun, Hui-nan; Lv, Shuang

    2008-10-01

    Monitoring of electric-cardio signals is the most direct method of discovering heart diseases. This article presents an electric-cardio signal acquisition and processing system based on DSP. According to the features of electric-cardio signals, the proposed system uses the AgCl electrode as electric-cardio signals sensor, and acquires analog signals with AD620 as the prepositional amplifier, and the digital system equipped is with TMS320LF2407A DSP. The design of digital filter and the analysis of heart rate variation are realized by programming in the DSP. Finally the ECG is obtained with P and T waves along with obvious QRS multi-wave characteristics. The system has low power dissipation, low cost and high precision, which meets the requirements for medical instruments.

  12. Heart rate profile during exercise in patients with early repolarization.

    PubMed

    Cay, Serkan; Cagirci, Goksel; Atak, Ramazan; Balbay, Yucel; Demir, Ahmet Duran; Aydogdu, Sinan

    2010-09-01

    Both early repolarization and altered heart rate profile are associated with sudden death. In this study, we aimed to demonstrate an association between early repolarization and heart rate profile during exercise. A total of 84 subjects were included in the study. Comparable 44 subjects with early repolarization and 40 subjects with normal electrocardiogram underwent exercise stress testing. Resting heart rate, maximum heart rate, heart rate increment and decrement were analyzed. Both groups were comparable for baseline characteristics including resting heart rate. Maximum heart rate, heart rate increment and heart rate decrement of the subjects in early repolarization group had significantly decreased maximum heart rate, heart rate increment and heart rate decrement compared to control group (all P < 0.05). The lower heart rate increment (< 106 beats/min) and heart rate decrement (< 95 beats/min) were significantly associated with the presence of early repolarization. After adjustment for age and sex, the multiple-adjusted OR of the risk of presence of early repolarization was 2.98 (95%CI 1.21-7.34) (P = 0.018) and 7.73 (95%CI 2.84-21.03) (P < 0.001) for the lower heart rate increment and heart rate decrement compared to higher levels, respectively. Subjects with early repolarization have altered heart rate profile during exercise compared to control subjects. This can be related to sudden death.

  13. Automatic zebrafish heartbeat detection and analysis for zebrafish embryos.

    PubMed

    Pylatiuk, Christian; Sanchez, Daniela; Mikut, Ralf; Alshut, Rüdiger; Reischl, Markus; Hirth, Sofia; Rottbauer, Wolfgang; Just, Steffen

    2014-08-01

    A fully automatic detection and analysis method of heartbeats in videos of nonfixed and nonanesthetized zebrafish embryos is presented. This method reduces the manual workload and time needed for preparation and imaging of the zebrafish embryos, as well as for evaluating heartbeat parameters such as frequency, beat-to-beat intervals, and arrhythmicity. The method is validated by a comparison of the results from automatic and manual detection of the heart rates of wild-type zebrafish embryos 36-120 h postfertilization and of embryonic hearts with bradycardia and pauses in the cardiac contraction.

  14. PREVENtion of HeartMate II Pump Thrombosis Through Clinical Management: The PREVENT multi-center study.

    PubMed

    Maltais, Simon; Kilic, Ahmet; Nathan, Sriram; Keebler, Mary; Emani, Sitaramesh; Ransom, John; Katz, Jason N; Sheridan, Brett; Brieke, Andreas; Egnaczyk, Gregory; Entwistle, John W; Adamson, Robert; Stulak, John; Uriel, Nir; O'Connell, John B; Farrar, David J; Sundareswaran, Kartik S; Gregoric, Igor

    2017-01-01

    Recommended structured clinical practices including implant technique, anti-coagulation strategy, and pump speed management (PREVENT [PREVENtion of HeartMate II Pump Thrombosis Through Clinical Management] recommendations) were developed to address risk of early (<3 months) pump thrombosis (PT) risk with HeartMate II (HMII; St. Jude Medical, Inc. [Thoratec Corporation], Pleasanton, CA). We prospectively assessed the HMII PT rate in the current era when participating centers adhered to the PREVENT recommendations. PREVENT was a prospective, multi-center, single-arm, non-randomized study of 300 patients implanted with HMII at 24 participating sites. Confirmed PT (any suspected PT confirmed visually and/or adjudicated by an independent assessor) was evaluated at 3 months (primary end-point) and at 6 months after implantation. The population included 83% men (age 57 years ± 13), 78% destination therapy, and 83% Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) Profile 1-3. Primary end-point analysis showed a confirmed PT of 2.9% at 3 months and 4.8% at 6 months. Adherence to key recommendations included 78% to surgical recommendations, 95% to heparin bridging, and 79% to pump speeds ≥9,000 RPMs (92% >8,600 RPMs). Full adherence to implant techniques, heparin bridging, and pump speeds ≥9,000 RPMs resulted in a significantly lower risk of PT (1.9% vs 8.9%; p < 0.01) and lower composite risk of suspected thrombosis, hemolysis, and ischemic stroke (5.7% vs 17.7%; p < 0.01) at 6 months. Adoption of all components of a structured surgical implant technique and clinical management strategy (PREVENT recommendations) is associated with low rates of confirmed PT. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  15. The effect of meditation on regulation of internal body states

    PubMed Central

    Khalsa, Sahib S.; Rudrauf, David; Davidson, Richard J.; Tranel, Daniel

    2015-01-01

    Meditation is commonly thought to induce physiologically quiescent states, as evidenced by decreased autonomic parameters during the meditation practice including reduced heart rate, respiratory rate, blood pressure, skin conductance, and increased alpha activity in the electroencephalogram. Preliminary empirical support for this idea was provided in a case report by Dimsdale and Mills (2002), where it was found that meditation seemed to regulate increased levels of cardiovascular arousal induced by bolus isoproterenol infusions. In that study, while meditating, a self-taught meditator exhibited unexpected decreases in heart rate while receiving moderate intravenous doses of the beta adrenergic agonist isoproterenol. This effect was no longer observed when the individual received isoproterenol infusions while not meditating. The current study was designed to explore this phenomenon empirically in a group of formally trained meditators. A total of 15 meditators and 15 non-meditators individually matched on age, sex, and body mass index were recruited. Participants received four series of infusions in a pseudorandomized order: isoproterenol while meditating (or during a relaxation condition for the non-meditators), isoproterenol while resting, saline while meditating (or during a relaxation condition for the non-meditators), and saline while resting. Heart rate was continuously measured throughout all infusions, and several measures of heart rate were derived from the instantaneous cardiac waveform. There was no evidence at the group or individual level suggesting that meditation reduced the cardiovascular response to isoproterenol, across all measures. These results suggest that meditation is not associated with increased regulation of elevated cardiac adrenergic tone. PMID:26217263

  16. Diagnostic accuracy and image quality of cardiac dual-source computed tomography in patients with arrhythmia.

    PubMed

    Tsiflikas, Ilias; Drosch, Tanja; Brodoefel, Harald; Thomas, Christoph; Reimann, Anja; Till, Alexander; Nittka, Daniel; Kopp, Andreas F; Schroeder, Stephen; Heuschmid, Martin; Burgstahler, Christof

    2010-08-06

    Cardiac multi-detector computed tomography (MDCT) permits accurate visualization of high-grade coronary artery stenosis. However, in patients with heart rate irregularities, MDCT was found to have limitations. Thus, the aim of the present study was to evaluate the diagnostic accuracy of a new dual-source computed tomography (DSCT) scanner generation with 83 ms temporal resolution in patients without stable sinus rhythm. 44 patients (31 men, mean age 67.5+/-9.2 years) without stable sinus rhythm and scheduled for invasive coronary angiography (ICA) because of suspected (n=17) or known coronary artery disease (CAD, n=27) were included in this study. All patients were examined with DSCT (Somatom Definition, Siemens). Besides assessment of total calcium score, all coronary segments were analyzed with regard to the presence of significant coronary artery lesions (>50%). The findings were compared to ICA in a blinded fashion. During CT examination, heart rhythm was as follows: 25 patients (57%) atrial fibrillation, 7 patients (16%) ventricular extrasystoles (two of them with atrial fibrillation), 4 patients (9%) supraventricular extrasystoles, 10 patients (23%) sinus arrhythmia (heart rate variability>10 bpm). Mean heart rate was 69+/-14 bpm, median 65 bpm. Mean Agatston score equivalent (ASE) was 762, ranging from 0 to 4949.7 ASE. Prevalence of CAD was 68% (30/44). 155 segments (27%) showed "step-ladder" artifacts and 28 segments (5%) could not be visualized by DSCT. Only 70 segments (12%) were completely imaged without any artifacts. Based on a coronary segment model, sensitivity was 73%, specificity 91%, positive predictive value 63%, and negative predictive value 94% for the detection of significant lesions (>or=50% diameter stenosis). Overall accuracy was 88%. In patients with heart rate irregularities, including patients with atrial fibrillation and a high prevalence of coronary artery disease, the diagnostic yield of dual-source computed tomography is still hampered due to a high number of segments with "step-ladder" artifacts. Copyright (c) 2009 Elsevier Ireland Ltd. All rights reserved.

  17. [Stress parameters and behaviour of horses in walkers with and without the use of electricity].

    PubMed

    Giese, C; Gerber, V; Howald, M; Bachmann, I; Burger, D

    2014-04-01

    In order to investigate stress responses of horses in walkers with and without electricity, 12 horses were trained during 3 weeks in a horse walker with and without the use of electricity (3.7 kV). To evaluate the stress response, cortisol levels in the blood were measured, the heart rate was monitored using the Polar® system and the behaviour was evaluated. Neither the cortisol levels nor the heart rates showed any relevant statistically significant difference between horses moved in the horse walker with or without the use of electricity. The highest cortisol levels and heart rates were recorded during the first week (habituation period). A significant difference could be observed regarding spontaneous compartment changes: while this happened mainly during the first week and before the first use of electricity, no horses changed compartments in the periods when electricity was used and thereafter. The results of this study indicate that the use of electricity in the horse walker does not seem to cause significant detectable stress in the horses.

  18. Physiological analysis to quantify training load in badminton.

    PubMed Central

    Majumdar, P; Khanna, G L; Malik, V; Sachdeva, S; Arif, M; Mandal, M

    1997-01-01

    OBJECTIVE: To estimate the training load of specific on court training regimens based on the magnitude of variation of heart rate-lactate response during specific training and to determine the magnitude of variation of biochemical parameters (urea, uric acid, and creatine phosphokinase (CPK)) 12 hours after the specific training programme so as to assess training stress. METHODS: The study was conducted on six national male badminton players. Maximum oxygen consumption (VO2), ventilation (VE), heart rate, and respiratory quotient were measured by a protocol of graded treadmill exercise. Twelve training sessions and 35 singles matches were analysed. Heart rate and blood lactate were monitored during technical training routines and match play. Fasting blood samples collected on two occasions--that is, during off season and 12 hours after specific training--were analysed for serum urea, uric acid, and CPK. RESULTS: Analysis of the on court training regimens showed lactate values of 8-10.5 mmol/l in different phases. The percentage of maximum heart rate ranged from 82% to 100%. Urea, uric acid, and CPK activity showed significant changes from (mean (SD)) 4.93 (0.75) mmol/l to 5.49 (0.84) mmol/l, 0.23 (0.04) to 0.33 (0.06) mmol/l, and 312 (211.8) to 363 (216.4) IU/l respectively. CONCLUSION: Maximum lactate reported in the literature ranges from 3-6 mmol/l. Comparatively high lactate values and high percentage of maximum heart rate found in on court training show a considerable stress on muscular and cardiovascular system. The training load needs appropriate monitoring to avoid over-training. Workouts that are too intensive may interfere with coordination, a factor that is important in sports requiring highly technical skill such as badminton. PMID:9429015

  19. Sympathoadrenal balance and physiological stress response in cattle at spontaneous and PGF2α-induced calving.

    PubMed

    Nagel, Christina; Trenk, Lisa; Aurich, Christine; Ille, Natascha; Pichler, Martina; Drillich, Marc; Pohl, Werner; Aurich, Jörg

    2016-03-15

    Increased cortisol release in parturient cows may either represent a stress response or is part of the endocrine changes that initiate calving. Acute stress elicits an increase in heart rate and decrease in heart rate variability (HRV). Therefore, we analyzed cortisol concentration, heart rate and HRV variables standard deviation of beat-to-beat interval (SDRR) and root mean square of successive beat-to-beat intervals (RMSSD) in dairy cows allowed to calve spontaneously (SPON, n = 6) or with PGF2α-induced preterm parturition (PG, n = 6). We hypothesized that calving is a stressor, but induced parturition is less stressful than term calving. Saliva collection for cortisol analysis and electrocardiogram recordings for heart rate and HRV analysis were performed from 32 hours before to 18.3 ± 0.7 hours after delivery. Cortisol concentration increased in SPON and PG cows, peaked 15 minutes after delivery (P < 0.001) but was higher in SPON versus PG cows (P < 0.001) during and within 2 hours after calving. Heart rate peaked during the expulsive phase of labor and was higher in SPON than in PG cows (time × group P < 0.01). The standard deviation of beat-to-beat interval and RMSSD peaked at the end of the expulsive phase of labor (P < 0.001), indicating high vagal activity. Standard deviation of beat-to-beat interval (P < 0.01) and RMSSD (P < 0.05) were higher in SPON versus PG cows. Based on physiological stress parameters, calving is perceived as stressful but expulsion of the calf is associated with a transiently increased vagal tone which may enhance uterine contractility. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Measurement of the efficacy of 2% lipid in reversing bupivacaine- induced asystole in isolated rat hearts

    PubMed Central

    2014-01-01

    Background The reversal efficacy of 2% lipid emulsion in cardiac asystole induced by different concentrations of bupivacaine is poorly defined and needs to be determined. Methods Forty-two male Sprague–Dawley rats were randomly divided into seven groups: B40, B60, B80, B100, B120, B140 and B160, n = 6. The Langendorff isolated heart perfusion model was used, which consisted of a balanced perfusion with Krebs-Henseleit solution for 25 minutes and a continuous infusion of 100 μmol/L bupivacaine until asystole had been induced for 3 minutes. The hearts in the seven groups were perfused with Krebs-Henseleit solution containing a 2% lipid emulsion, and 40, 60, 80, 100, 120, 140 or 160 μmol/L bupivacaine, respectively. Cardiac recovery was defined as a spontaneous and regular rhythm with a rate-pressure product > 10% of the baseline value for more than 1 minute. Our primary outcome was the rate-pressure product 25 minutes after cardiac recovery. Other cardiac function parameters were also recorded. Results All groups demonstrated cardiac recovery. During the recovery phase, heart rate, rate-pressure product, the maximum left ventricular pressure rise and decline in heart rate in the B120-B160 groups was significantly lower than those in the B40-B80 groups (P < 0.05). The concentration of bupivacaine and the reversal effects of a 2% lipid emulsion showed a typical transoid S-shaped curve, R2 = 0.9983, IC50 value was 102.5 μmol/L (95% CI: 92.44 - 113.6). Conclusions There is a concentration-response relationship between the concentrations of bupivacaine and the reversal effects of 2% lipid emulsion. PMID:25089118

  1. Hemodynamics of a functional centrifugal-flow total artificial heart with functional atrial contraction in goats.

    PubMed

    Shiga, Takuya; Shiraishi, Yasuyuki; Sano, Kyosuke; Taira, Yasunori; Tsuboko, Yusuke; Yamada, Akihiro; Miura, Hidekazu; Katahira, Shintaro; Akiyama, Masatoshi; Saiki, Yoshikatsu; Yambe, Tomoyuki

    2016-03-01

    Implantation of a total artificial heart (TAH) is one of the therapeutic options for the treatment of patients with end-stage biventricular heart failure. There is no report on the hemodynamics of the functional centrifugal-flow TAH with functional atrial contraction (fCFTAH). We evaluated the effects of pulsatile flow by atrial contraction in acute animal models. The goats received fCFTAH that we created from two centrifugal-flow ventricular assist devices. Some hemodynamic parameters maintained acceptable levels: heart rate 115.5 ± 26.3 bpm, aortic pressure 83.5 ± 10.1 mmHg, left atrial pressure 18.0 ± 5.9 mmHg, pulmonary pressure 28.5 ± 9.7 mmHg, right atrial pressure 13.6 ± 5.2 mmHg, pump flow 4.0 ± 1.1 L/min (left) 3.9 ± 1.1 L/min (right), and cardiac index 2.13 ± 0.14 L/min/m(2). fCFTAH with atrial contraction was able to maintain the TAH circulation by forming a pulsatile flow in acute animal experiments. Taking the left and right flow rate balance using the low internal pressure loss of the VAD pumps may be easier than by other pumps having considerable internal pressure loss. We showed that the remnant atrial contraction effected the flow rate change of the centrifugal pump, and the atrial contraction waves reflected the heart rate. These results indicate that remnant atria had the possibility to preserve autonomic function in fCFTAH. We may control fCFTAH by reflecting the autonomic function, which is estimated with the flow rate change of the centrifugal pump.

  2. Gender differences in autonomic cardiovascular regulation: spectral, hormonal, and hemodynamic indexes

    NASA Technical Reports Server (NTRS)

    Evans, J. M.; Ziegler, M. G.; Patwardhan, A. R.; Ott, J. B.; Kim, C. S.; Leonelli, F. M.; Knapp, C. F.

    2001-01-01

    The autonomic nervous system drives variability in heart rate, vascular tone, cardiac ejection, and arterial pressure, but gender differences in autonomic regulation of the latter three parameters are not well documented. In addition to mean values, we used spectral analysis to calculate variability in arterial pressure, heart rate (R-R interval, RRI), stroke volume, and total peripheral resistance (TPR) and measured circulating levels of catecholamines and pancreatic polypeptide in two groups of 25 +/- 1.2-yr-old, healthy men and healthy follicular-phase women (40 total subjects, 10 men and 10 women per group). Group 1 subjects were studied supine, before and after beta- and muscarinic autonomic blockades, administered singly and together on separate days of study. Group 2 subjects were studied supine and drug free with the additional measurement of skin perfusion. In the unblocked state, we found that circulating levels of epinephrine and total spectral power of stroke volume, TPR, and skin perfusion ranged from two to six times greater in men than in women. The difference (men > women) in spectral power of TPR was maintained after beta- and muscarinic blockades, suggesting that the greater oscillations of vascular resistance in men may be alpha-adrenergically mediated. Men exhibited muscarinic buffering of mean TPR whereas women exhibited beta-adrenergic buffering of mean TPR as well as TPR and heart rate oscillations. Women had a greater distribution of RRI power in the breathing frequency range and a less negative slope of ln RRI power vs. ln frequency, both indicators that parasympathetic stimuli were the dominant influence on women's heart rate variability. The results of our study suggest a predominance of sympathetic vascular regulation in men compared with a dominant parasympathetic influence on heart rate regulation in women.

  3. (-) Epicatechin attenuates mitochondrial damage by enhancing mitochondrial multi-marker enzymes, adenosine triphosphate and lowering calcium in isoproterenol induced myocardial infarcted rats.

    PubMed

    Stanely Mainzen Prince, P

    2013-03-01

    Cardiac mitochondrial damage plays an important role in the pathology of myocardial infarction. The protective effects of (-) epicatechin on cardiac mitochondrial damage in isoproterenol induced myocardial infarction were evaluated in rats. Rats were pretreated with (-) epicatechin (20 mg/kg body weight) daily for a period of 21 days. After the pretreatment period, isoproterenol (100 mg/kg body weight) was injected subcutaneously into rats twice at an interval of 24 h to induce myocardial infarction. Isoproterenol induced myocardial infarcted rats showed a significant increase in the levels of cardiac diagnostic markers, heart mitochondrial lipid peroxidation, calcium, and a significant decrease in the activities/levels of heart mitochondrial glutathione peroxidase, glutathione reductase, reduced glutathione, isocitrate, succinate, malate, α-ketoglutarate and NADH-dehydrogenases, cytochrome-C-oxidase and adenosine triphosphate. (-) Epicatechin pretreatment showed significant protective effects on all the biochemical parameters evaluated. The in vitro study revealed the superoxide and hydroxyl radical scavenging activity of (-) epicatechin. The possible mechanisms for the beneficial effects of (-) epicatechin on cardiac mitochondria could be attributed to scavenging of free radicals, decreasing calcium, increasing multi-enzymes (antioxidant, tricarboxylic acid cycle and respiratory chain enzymes), reduced glutathione and adenosine triphosphate. Thus, (-) epicatechin attenuated mitochondrial damage in isoproterenol induced myocardial infarcted rats. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. Heart Rate and Systolic Blood Pressure Variability in the Time Domain in Patients with Recent and Long-Standing Diabetes Mellitus

    PubMed Central

    Rivera, Ana Leonor; Estañol, Bruno; Sentíes-Madrid, Horacio; Fossion, Ruben; Toledo-Roy, Juan C.; Mendoza-Temis, Joel; Morales, Irving O.; Landa, Emmanuel; Robles-Cabrera, Adriana; Moreno, Rene; Frank, Alejandro

    2016-01-01

    Diabetes Mellitus (DM) affects the cardiovascular response of patients. To study this effect, interbeat intervals (IBI) and beat-to-beat systolic blood pressure (SBP) variability of patients during supine, standing and controlled breathing tests were analyzed in the time domain. Simultaneous noninvasive measurements of IBI and SBP for 30 recently diagnosed and 15 long-standing DM patients were compared with the results for 30 rigorously screened healthy subjects (control). A statistically significant distinction between control and diabetic subjects was provided by the standard deviation and the higher moments of the distributions (skewness, and kurtosis) with respect to the median. To compare IBI and SBP for different populations, we define a parameter, α, that combines the variability of the heart rate and the blood pressure, as the ratio of the radius of the moments for IBI and the same radius for SBP. As diabetes evolves, α decreases, standard deviation of the IBI detrended signal diminishes (heart rate signal becomes more “rigid”), skewness with respect to the median approaches zero (signal fluctuations gain symmetry), and kurtosis increases (fluctuations concentrate around the median). Diabetes produces not only a rigid heart rate, but also increases symmetry and has leptokurtic distributions. SBP time series exhibit the most variable behavior for recently diagnosed DM with platykurtic distributions. Under controlled breathing, SBP has symmetric distributions for DM patients, while control subjects have non-zero skewness. This may be due to a progressive decrease of parasympathetic and sympathetic activity to the heart and blood vessels as diabetes evolves. PMID:26849653

  5. Heart Rate and Systolic Blood Pressure Variability in the Time Domain in Patients with Recent and Long-Standing Diabetes Mellitus.

    PubMed

    Rivera, Ana Leonor; Estañol, Bruno; Sentíes-Madrid, Horacio; Fossion, Ruben; Toledo-Roy, Juan C; Mendoza-Temis, Joel; Morales, Irving O; Landa, Emmanuel; Robles-Cabrera, Adriana; Moreno, Rene; Frank, Alejandro

    2016-01-01

    Diabetes Mellitus (DM) affects the cardiovascular response of patients. To study this effect, interbeat intervals (IBI) and beat-to-beat systolic blood pressure (SBP) variability of patients during supine, standing and controlled breathing tests were analyzed in the time domain. Simultaneous noninvasive measurements of IBI and SBP for 30 recently diagnosed and 15 long-standing DM patients were compared with the results for 30 rigorously screened healthy subjects (control). A statistically significant distinction between control and diabetic subjects was provided by the standard deviation and the higher moments of the distributions (skewness, and kurtosis) with respect to the median. To compare IBI and SBP for different populations, we define a parameter, α, that combines the variability of the heart rate and the blood pressure, as the ratio of the radius of the moments for IBI and the same radius for SBP. As diabetes evolves, α decreases, standard deviation of the IBI detrended signal diminishes (heart rate signal becomes more "rigid"), skewness with respect to the median approaches zero (signal fluctuations gain symmetry), and kurtosis increases (fluctuations concentrate around the median). Diabetes produces not only a rigid heart rate, but also increases symmetry and has leptokurtic distributions. SBP time series exhibit the most variable behavior for recently diagnosed DM with platykurtic distributions. Under controlled breathing, SBP has symmetric distributions for DM patients, while control subjects have non-zero skewness. This may be due to a progressive decrease of parasympathetic and sympathetic activity to the heart and blood vessels as diabetes evolves.

  6. Comparison of carbon dioxide and argon euthanasia: effects on behavior, heart rate, and respiratory lesions in rats.

    PubMed

    Burkholder, Tanya H; Niel, Lee; Weed, James L; Brinster, Lauren R; Bacher, John D; Foltz, Charmaine J

    2010-07-01

    In this study we compared rat (n = 16) responses to euthanasia with either gradual-fill CO(2) or rapid induction argon gas by evaluating the animals' heart rate via radiotelemetry, behavior, and vocalizations. We also evaluated the histologic effects of the gases. Rats were placed in an open test chamber 24 h before the start of the experiment. During baseline tests, rats were exposed to oxygen to evaluate the effects of the noise and movement of gas entering the chamber; 1 wk later, rats were euthanized by gas displacement with either 10%/min CO(2) or 50%/min argon gas. Rats tended to have higher heart rats and were more active during the baseline test, but these parameters were normal before the euthanasia experiment, suggesting that the rats had acclimated to the equipment. Heart rate, behavior, and ultrasonic vocalizations were recorded for 2 min after gas introduction in both groups. All rats appeared conscious throughout the test interval. The heart rates of rats exposed to argon did not change, whereas those of rats exposed to CO(2) declined significantly. Unlike those exposed to CO(2), rats euthanized with argon gas gasped and demonstrated seizure-like activity. There were no differences in the pulmonary lesions resulting from death by either gas. Our results suggest that argon as a sole euthanasia agent is aversive to rats. CO(2) using a 10%/min displacement may be less aversive than more rapid displacements. Future research investigating methods of euthanasia should allow sufficient time for the rats to acclimate to the test apparatus.

  7. A novel technique for fetal heart rate estimation from Doppler ultrasound signal

    PubMed Central

    2011-01-01

    Background The currently used fetal monitoring instrumentation that is based on Doppler ultrasound technique provides the fetal heart rate (FHR) signal with limited accuracy. It is particularly noticeable as significant decrease of clinically important feature - the variability of FHR signal. The aim of our work was to develop a novel efficient technique for processing of the ultrasound signal, which could estimate the cardiac cycle duration with accuracy comparable to a direct electrocardiography. Methods We have proposed a new technique which provides the true beat-to-beat values of the FHR signal through multiple measurement of a given cardiac cycle in the ultrasound signal. The method consists in three steps: the dynamic adjustment of autocorrelation window, the adaptive autocorrelation peak detection and determination of beat-to-beat intervals. The estimated fetal heart rate values and calculated indices describing variability of FHR, were compared to the reference data obtained from the direct fetal electrocardiogram, as well as to another method for FHR estimation. Results The results revealed that our method increases the accuracy in comparison to currently used fetal monitoring instrumentation, and thus enables to calculate reliable parameters describing the variability of FHR. Relating these results to the other method for FHR estimation we showed that in our approach a much lower number of measured cardiac cycles was rejected as being invalid. Conclusions The proposed method for fetal heart rate determination on a beat-to-beat basis offers a high accuracy of the heart interval measurement enabling reliable quantitative assessment of the FHR variability, at the same time reducing the number of invalid cardiac cycle measurements. PMID:21999764

  8. Comparison of Carbon Dioxide and Argon Euthanasia: Effects on Behavior, Heart Rate, and Respiratory Lesions in Rats

    PubMed Central

    Burkholder, Tanya H; Niel, Lee; Weed, James L; Brinster, Lauren R; Bacher, John D; Foltz, Charmaine J

    2010-01-01

    In this study we compared rat (n = 16) responses to euthanasia with either gradual-fill CO2 or rapid induction argon gas by evaluating the animals' heart rate via radiotelemetry, behavior, and vocalizations. We also evaluated the histologic effects of the gases. Rats were placed in an open test chamber 24 h before the start of the experiment. During baseline tests, rats were exposed to oxygen to evaluate the effects of the noise and movement of gas entering the chamber; 1 wk later, rats were euthanized by gas displacement with either 10%/min CO2 or 50%/min argon gas. Rats tended to have higher heart rats and were more active during the baseline test, but these parameters were normal before the euthanasia experiment, suggesting that the rats had acclimated to the equipment. Heart rate, behavior, and ultrasonic vocalizations were recorded for 2 min after gas introduction in both groups. All rats appeared conscious throughout the test interval. The heart rates of rats exposed to argon did not change, whereas those of rats exposed to CO2 declined significantly. Unlike those exposed to CO2, rats euthanized with argon gas gasped and demonstrated seizure-like activity. There were no differences in the pulmonary lesions resulting from death by either gas. Our results suggest that argon as a sole euthanasia agent is aversive to rats. CO2 using a 10%/min displacement may be less aversive than more rapid displacements. Future research investigating methods of euthanasia should allow sufficient time for the rats to acclimate to the test apparatus. PMID:20819391

  9. PM2.5 EXPOSURE CHANGES HEART RATE VARIABILITY (HRV) AND BLOOD PARAMETERS IN STATE HIGHWAY PATROL TROOPERS

    EPA Science Inventory

    Epidemiological studies show an association between ambient particulate matter PM and cardiovascular mortality. Panel and controlled exposure studies report PM-associated changes in HRV and blood factors involved in clotting and inflammation. We investigated the effects of in-veh...

  10. Global electrical heterogeneity as a predictor of cardiovascular mortality in men and women.

    PubMed

    Lipponen, Jukka A; Kurl, Sudhir; Laukkanen, Jari A

    2018-06-02

    The aim of this study was to investigate the contribution of depolarization and repolarization abnormalities, specially abnormalities in global electrical heterogeneity of heart in cardiovascular disease (CVD) and all-cause mortality. Eight hundred and forty men and 911 women, average age of 63 years participated in this study with average follow-up was 14 years. Six electrocardiogram/vector electrocardiogram (ECG/VECG) markers QRS-duration, QTc-interval, QRST-angle, sum of absolute QRST integral (SAI QRST), T-wave roundness, and TV1-amplitude were estimated from VECG measurements. Hazard ratios (HRs) for CVD events (164 deaths) and all-cause mortality (383 deaths) for ECG parameters were calculated. Electrocardiogram or vector electrocardiogram parameter models adjusted for risk clinical factors showed that strongest predictors for CVD mortality were QRST-angle (HR 3.44, 95% confidence interval 2.12-5.36), QTc-interval (2.72, 1.73-4.29), and T-wave roundness (2.09, 1.26-3.46) among men. The strongest ECG/VECG parameters for CVD death were QRST-angle (2.47, 1.37-4.45), SAI QRST (2.37, 1.23-4.6), and QTc-interval (2.15, 1.16-4.01) among female participants. Multivariable adjusted models revealed that strongest independent ECG predictors for CVD death were QRST-angle, QTc-interval, resting heart rate, and T-roundness for men, QRST-angle and SAI QRST for women. QRST-angle, QTc-interval, resting heart rate, and T-roundness were associated with all-cause mortality in male population, although none of the ECG/VECG parameters predicted all-cause mortality among women. Characteristics of global electrical heterogeneity QRST-angle and QTc-interval in men and QRST-angle and SAI QRST among females were strong and independent risk markers for cardiovascular mortality. These parameters provide new additional ECG tools for cardiovascular risk stratification.

  11. Increased risks of coronary heart disease and stroke among spousal caregivers of cancer patients.

    PubMed

    Ji, Jianguang; Zöller, Bengt; Sundquist, Kristina; Sundquist, Jan

    2012-04-10

    Spousal caregivers of cancer patients suffer psychological and physical burdens that may affect their risk of subsequently developing coronary heart disease and stroke. Cancer patients were identified in the Swedish Cancer Registry, and information on their spouses was retrieved from the Swedish Multi-Generation Register. Follow-up of caregivers was performed from the date of the first diagnosis of cancer in their spouses through 2008. Standardized incidence ratios were calculated for spousal caregivers of cancer patients compared with those without an affected spouse. After the cancer diagnosis in wives, the risks of coronary heart disease, ischemic stroke, and hemorrhagic stroke in husbands were 1.13 (95% confidence interval [CI], 1.10-1.16), 1.24 (95% CI, 1.21-1.27), and 1.25 (95% CI, 1.18-1.32), respectively. The corresponding risks in wives with an affected husband were 1.13 (95% CI, 1.10-1.16), 1.29 (95% CI, 1.26-1.32), and 1.27 (95% CI, 1.19-1.34). The increases were consistent over time and were more pronounced if the spouse was affected by a cancer with a high mortality rate, such as pancreatic and lung cancers. Spousal caregivers of cancer patients have increased risks of coronary heart disease and stroke that persist over time. Clinical attention should be paid to spousal caregivers, especially those caring for cancer patients with high mortality rates.

  12. Enzyme-dependent fluorescence recovery of NADH after photobleaching to assess dehydrogenase activity of isolated perfused hearts

    NASA Astrophysics Data System (ADS)

    Moreno, Angel; Kuzmiak-Glancy, Sarah; Jaimes, Rafael; Kay, Matthew W.

    2017-03-01

    Reduction of NAD+ by dehydrogenase enzymes to form NADH is a key component of cellular metabolism. In cellular preparations and isolated mitochondria suspensions, enzyme-dependent fluorescence recovery after photobleaching (ED-FRAP) of NADH has been shown to be an effective approach for measuring the rate of NADH production to assess dehydrogenase enzyme activity. Our objective was to demonstrate how dehydrogenase activity could be assessed within the myocardium of perfused hearts using NADH ED-FRAP. This was accomplished using a combination of high intensity UV pulses to photobleach epicardial NADH. Replenishment of epicardial NADH fluorescence was then imaged using low intensity UV illumination. NADH ED-FRAP parameters were optimized to deliver 23.8 mJ of photobleaching light energy at a pulse width of 6 msec and a duty cycle of 50%. These parameters provided repeatable measurements of NADH production rate during multiple metabolic perturbations, including changes in perfusate temperature, electromechanical uncoupling, and acute ischemia/reperfusion injury. NADH production rate was significantly higher in every perturbation where the energy demand was either higher or uncompromised. We also found that NADH production rate remained significantly impaired after 10 min of reperfusion after global ischemia. Overall, our results indicate that myocardial NADH ED-FRAP is a useful optical non-destructive approach for assessing dehydrogenase activity.

  13. In-Pile Instrumentation Multi- Parameter System Utilizing Photonic Fibers and Nanovision

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burgett, Eric

    2015-10-13

    An advanced in-pile multi-parameter reactor monitoring system is being proposed in this funding opportunity. The proposed effort brings cutting edge, high fidelity optical measurement systems into the reactor environment in an unprecedented fashion, including in-core, in-cladding and in-fuel pellet itself. Unlike instrumented leads, the proposed system provides a unique solution to a multi-parameter monitoring need in core while being minimally intrusive in the reactor core. Detector designs proposed herein can monitor fuel compression and expansion in both the radial and axial dimensions as well as monitor linear power profiles and fission rates during the operation of the reactor. In additionmore » to pressure, stress, strain, compression, neutron flux, neutron spectra, and temperature can be observed inside the fuel bundle and fuel rod using the proposed system. The proposed research aims at developing radiation-hard, harsh-environment multi-parameter systems for insertion into the reactor environment. The proposed research holds the potential to drastically increase the fidelity and precision of in-core instrumentation with little or no impact in the neutron economy in the reactor environment while providing a measurement system capable of operation for entire operating cycles.« less

  14. Evaluation of efficacy and safety of glycopyrrolate - xylazine - propofol anesthesia in buffalo calves

    PubMed Central

    Potliya, Sandeep; Kumar, Ashok; Kumar, Sandeep; Singh, Sukhbir; Kumar, Sarvan

    2015-01-01

    Aim: To evaluate the efficacy and safety of glycopyrrolate - xylazine - propofol anesthesia in buffalo calves. Materials and Methods: The study was conducted on six clinically healthy male buffalo calves, 6-12 months of age, and weighing between 130 and 170 kg. In all the animals; glycopyrrolate (0.01 mg/kg, IM), xylazine (0.1 mg/kg, IM) and 1% propofol as single bolus (1.5 mg/kg, intravenous), were administered. The parameters observed included behavioral changes, physiological; hematological and blood biochemical parameters. Results: Muzzle and nostrils became dry in all the animals after glycopyrrolate administration. A decrease in spontaneous activity and mild cutaneous analgesia was noticed after xylazine administration. After administration of propofol, loss of swallowing reflex, palpebral reflex, corneal reflexes, periosteal reflex and complete analgesia was observed. There was no significant change in rectal temperature and heart rate. However, heart rate remained elevated during anesthesia. Respiratory rate decreased significantly after propofol administration. There was a significant increase in plasma glucose after the xylazine and propofol administration which remained elevated till recovery. A significant decrease in chloride level was seen after propofol administration. Conclusions: Glycopyrrolate - xylazine - propofol anesthetic combination may safely be used for short duration anesthesia in buffalo calves. PMID:27047082

  15. Electromagnetic energy radiated from mobile phone alters electrocardiographic records of patients with ischemic heart disease.

    PubMed

    Alhusseiny, Ah; Al-Nimer, Ms; Majeed, Ad

    2012-07-01

    Electromagnetic energy radiated from mobile phones did not show significant effect on the blood pressure, heart rate, and electrocardiographic (ECG) parameters in animals and humans. This study aimed to investigate the effect of radiofrequency of mobile phone on the electrocardiographic parameters in patients with history of ischemic heart disease, taking into consideration the gender factor. A total number of 356 participants (129 males and 227 females) were admitted in this study. They were grouped into: subjects without cardiac diseases (Group I), patients with ischemic heart disease (Group II), and patients with history of cardiac diseases not related to myocardial ischemia (Group III). Electrocardiogram was obtained from each patient when the mobile phone was placed at the belt level and over precordium in turn-off mode (baseline) and turn-on mode for 40 sec ringing. The records of ECG were electronically analyzed. Prolongation of QTc interval was significantly observed in male gender of Groups I and III (P < 0.001). Male patients of Group II showed significant QTc interval prolongation (P = 0.01) and changes in the voltage criteria (P = 0.001). These changes were not observed in female patients with ischemic heart disease. The position of mobile at the belt level or over the precordium showed effects on the heart. The radiofrequency of cell phone prolongs the QT interval in human beings and it interferes with voltage criteria of ECG records in male patients with myocardial ischemia.

  16. Cardiorespiratory Kinetics Determined by Pseudo-Random Binary Sequences - Comparisons between Walking and Cycling.

    PubMed

    Koschate, J; Drescher, U; Thieschäfer, L; Heine, O; Baum, K; Hoffmann, U

    2016-12-01

    This study aims to compare cardiorespiratory kinetics as a response to a standardised work rate protocol with pseudo-random binary sequences between cycling and walking in young healthy subjects. Muscular and pulmonary oxygen uptake (V̇O 2 ) kinetics as well as heart rate kinetics were expected to be similar for walking and cycling. Cardiac data and V̇O 2 of 23 healthy young subjects were measured in response to pseudo-random binary sequences. Kinetics were assessed applying time series analysis. Higher maxima of cross-correlation functions between work rate and the respective parameter indicate faster kinetics responses. Muscular V̇O 2 kinetics were estimated from heart rate and pulmonary V̇O 2 using a circulatory model. Muscular (walking vs. cycling [mean±SD in arbitrary units]: 0.40±0.08 vs. 0.41±0.08) and pulmonary V̇O 2 kinetics (0.35±0.06 vs. 0.35±0.06) were not different, although the time courses of the cross-correlation functions of pulmonary V̇O 2 showed unexpected biphasic responses. Heart rate kinetics (0.50±0.14 vs. 0.40±0.14; P=0.017) was faster for walking. Regarding the biphasic cross-correlation functions of pulmonary V̇O 2 during walking, the assessment of muscular V̇O 2 kinetics via pseudo-random binary sequences requires a circulatory model to account for cardio-dynamic distortions. Faster heart rate kinetics for walking should be considered by comparing results from cycle and treadmill ergometry. © Georg Thieme Verlag KG Stuttgart · New York.

  17. Significance of a positive family history for coronary heart disease in patients with a zero coronary artery calcium score (from the Multi-Ethnic Study of Atherosclerosis).

    PubMed

    Cohen, Randy; Budoff, Matthew; McClelland, Robyn L; Sillau, Stefan; Burke, Gregory; Blaha, Michael; Szklo, Moyses; Uretsky, Seth; Rozanski, Alan; Shea, Steven

    2014-10-15

    Although a coronary artery calcium (CAC) score of 0 is associated with a very low 10-year risk for cardiac events, this risk is nonzero. Subjects with a family history of coronary heart disease (CHD) has been associated with more subclinical atherosclerosis than subjects without a family history of CHD. The purpose of this study was to assess the significance of a family history for CHD in subjects with a CAC score of 0. The Multi-Ethnic Study of Atherosclerosis cohort includes 6,814 participants free of clinical cardiovascular disease (CVD) at baseline. Positive family history was defined as reporting a parent, sibling, or child who had a heart attack. Time to incident CHD or CVD event was modeled using the multivariable Cox regression; 3,185 subjects were identified from the original Multi-Ethnic Study of Atherosclerosis cohort as having a baseline CAC score of 0 (mean age 58 years, 37% men). Over a median follow-up of 10 years, 101 participants (3.2%) had CVD events and 56 (1.8%) had CHD events. In age- and gender-adjusted analyses, a family history of CHD was associated with an ∼70% increase in CVD (hazard ratio 1.73, 95% confidence interval 1.17 to 2.56) and CHD (hazard ratio 1.72, 95% confidence interval 1.01 to 2.91) events. CVD events remained significant after further adjustment for ethnicity, risk factors, and baseline medication use. In conclusion, asymptomatic subjects with a 0 CAC score and a positive family history of CHD are at increased risk for CVD and CHD events compared with those without a family history of CHD, although absolute event rates remain low. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Simulation Based Earthquake Forecasting with RSQSim

    NASA Astrophysics Data System (ADS)

    Gilchrist, J. J.; Jordan, T. H.; Dieterich, J. H.; Richards-Dinger, K. B.

    2016-12-01

    We are developing a physics-based forecasting model for earthquake ruptures in California. We employ the 3D boundary element code RSQSim to generate synthetic catalogs with millions of events that span up to a million years. The simulations incorporate rate-state fault constitutive properties in complex, fully interacting fault systems. The Unified California Earthquake Rupture Forecast Version 3 (UCERF3) model and data sets are used for calibration of the catalogs and specification of fault geometry. Fault slip rates match the UCERF3 geologic slip rates and catalogs are tuned such that earthquake recurrence matches the UCERF3 model. Utilizing the Blue Waters Supercomputer, we produce a suite of million-year catalogs to investigate the epistemic uncertainty in the physical parameters used in the simulations. In particular, values of the rate- and state-friction parameters a and b, the initial shear and normal stress, as well as the earthquake slip speed, are varied over several simulations. In addition to testing multiple models with homogeneous values of the physical parameters, the parameters a, b, and the normal stress are varied with depth as well as in heterogeneous patterns across the faults. Cross validation of UCERF3 and RSQSim is performed within the SCEC Collaboratory for Interseismic Simulation and Modeling (CISM) to determine the affect of the uncertainties in physical parameters observed in the field and measured in the lab, on the uncertainties in probabilistic forecasting. We are particularly interested in the short-term hazards of multi-event sequences due to complex faulting and multi-fault ruptures.

  19. The effects of heart rate control in chronic heart failure with reduced ejection fraction.

    PubMed

    Grande, Dario; Iacoviello, Massimo; Aspromonte, Nadia

    2018-07-01

    Elevated heart rate has been associated with worse prognosis both in the general population and in patients with heart failure. Heart rate is finely modulated by neurohormonal signals and it reflects the balance between the sympathetic and the parasympathetic limbs of the autonomic nervous system. For this reason, elevated heart rate in heart failure has been considered an epiphenomenon of the sympathetic hyperactivation during heart failure. However, experimental and clinical evidence suggests that high heart rate could have a direct pathogenetic role. Consequently, heart rate might act as a pathophysiological mediator of heart failure as well as a marker of adverse outcome. This hypothesis has been supported by the observation that the positive effect of beta-blockade could be linked to the degree of heart rate reduction. In addition, the selective heart rate control with ivabradine has recently been demonstrated to be beneficial in patients with heart failure and left ventricular systolic dysfunction. The objective of this review is to examine the pathophysiological implications of elevated heart rate in chronic heart failure and explore the mechanisms underlying the effects of pharmacological heart rate control.

  20. First-pass myocardial perfusion imaging with whole-heart coverage using L1-SPIRiT accelerated variable density spiral trajectories.

    PubMed

    Yang, Yang; Kramer, Christopher M; Shaw, Peter W; Meyer, Craig H; Salerno, Michael

    2016-11-01

    To design and evaluate two-dimensional (2D) L1-SPIRiT accelerated spiral pulse sequences for first-pass myocardial perfusion imaging with whole heart coverage capable of measuring eight slices at 2 mm in-plane resolution at heart rates up to 125 beats per minute (BPM). Combinations of five different spiral trajectories and four k-t sampling patterns were retrospectively simulated in 25 fully sampled datasets and reconstructed with L1-SPIRiT to determine the best combination of parameters. Two candidate sequences were prospectively evaluated in 34 human subjects to assess in vivo performance. A dual density broad transition spiral trajectory with either angularly uniform or golden angle in time k-t sampling pattern had the largest structural similarity and smallest root mean square error from the retrospective simulation, and the L1-SPIRiT reconstruction had well-preserved temporal dynamics. In vivo data demonstrated that both of the sampling patterns could produce high quality perfusion images with whole-heart coverage. First-pass myocardial perfusion imaging using accelerated spirals with optimized trajectory and k-t sampling pattern can produce high quality 2D perfusion images with whole-heart coverage at the heart rates up to 125 BPM. Magn Reson Med 76:1375-1387, 2016. © 2015 International Society for Magnetic Resonance in Medicine. © 2015 International Society for Magnetic Resonance in Medicine.

Top