Sample records for multi-taper method mtm

  1. Optimization of PET-MR Registrations for Nonhuman Primates Using Mutual Information Measures: A Multi-Transform Method (MTM)

    PubMed Central

    Sandiego, Christine M.; Weinzimmer, David; Carson, Richard E.

    2012-01-01

    An important step in PET brain kinetic analysis is the registration of functional data to an anatomical MR image. Typically, PET-MR registrations in nonhuman primate neuroreceptor studies used PET images acquired early post-injection, (e.g., 0–10 min) to closely resemble the subject’s MR image. However, a substantial fraction of these registrations (~25%) fail due to the differences in kinetics and distribution for various radiotracer studies and conditions (e.g., blocking studies). The Multi-Transform Method (MTM) was developed to improve the success of registrations between PET and MR images. Two algorithms were evaluated, MTM-I and MTM-II. The approach involves creating multiple transformations by registering PET images of different time intervals, from a dynamic study, to a single reference (i.e., MR image) (MTM-I) or to multiple reference images (i.e., MR and PET images pre-registered to the MR) (MTM-II). Normalized mutual information was used to compute similarity between the transformed PET images and the reference image(s) to choose the optimal transformation. This final transformation is used to map the dynamic dataset into the animal’s anatomical MR space, required for kinetic analysis. The chosen transformed from MTM-I and MTM-II were evaluated using visual rating scores to assess the quality of spatial alignment between the resliced PET and reference. One hundred twenty PET datasets involving eleven different tracers from 3 different scanners were used to evaluate the MTM algorithms. Studies were performed with baboons and rhesus monkeys on the HR+, HRRT, and Focus-220. Successful transformations increased from 77.5%, 85.8%, to 96.7% using the 0–10 min method, MTM-I, and MTM-II, respectively, based on visual rating scores. The Multi-Transform Methods proved to be a robust technique for PET-MR registrations for a wide range of PET studies. PMID:22926293

  2. Multiple Signal Classification for Determining Direction of Arrival of Frequency Hopping Spread Spectrum Signals

    DTIC Science & Technology

    2014-03-27

    42 4.2.3 Number of Hops Hs . . . . . . . . . . . . . . . . . . . . . . . . . 45 4.2.4 Number of Sensors M... 45 4.5 Standard deviation vs. Ns. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 4.6 Bias...laboratory MTM multiple taper method MUSIC multiple signal classification MVDR minimum variance distortionless reposnse PSK phase shift keying QAM

  3. The stratospheric QBO signal in the NCEP reanalysis, 1958-2001

    NASA Astrophysics Data System (ADS)

    Ribera, Pedro; Gallego, David; Peña-Ortiz, Cristina; Gimeno, Luis; Garcia-Herrera, Ricardo; Hernandez, Emiliano; Calvo, Natalia

    2003-07-01

    The spatiotemporal evolution of the zonal wind in the stratosphere is analyzed based on the use of the NCEP reanalysis (1958-2001). MultiTaper Method-Singular Value Decomposition (MTM-SVD), a frequency-domain analysis method, is applied to isolate significant spatially-coherent variability with narrowband oscillatory character. A quasibiennial oscillation is detected as the most intense coherent signal in the stratosphere, the signal being less intense in the lower levels. There is a clear downward propagation of the signal with time at low latitudes, not evident at mid and high latitudes. There are differences in the behavior of the signal over both hemispheres, being much weaker over the SH. In the NH an anomaly in the zonal wind field, in phase with the equatorial signal, is detected at approximately 60°N. Two different areas at subtropical latitudes are detected to be characterized by wind anomalies opposed to that of the equator.

  4. Applying a new theory to smoking cessation: case of multi-theory model (MTM) for health behavior change.

    PubMed

    Sharma, Manoj; Khubchandani, Jagdish; Nahar, Vinayak K

    2017-01-01

    Background: Smoking continues to be a public health problem worldwide. Smoking and tobacco use are associated with cardiovascular diseases that include coronary heart disease, atherosclerosis, cerebrovascular disease, and abdominal aortic aneurysm. Programs for quitting smoking have played a significant role in reduction of smoking in the United States. The smoking cessation interventions include counseling, nicotine replacement therapy, buproprion therapy, and varenicline therapy. The success rates with each of these approaches vary with clear need for improvement. Moreover, there is a need for a robust theory that can guide smoking cessation counseling interventions and increase the success rates. A fourth generation approach using multi-theory model (MTM) of health behavior change is introduced in this article for smoking cessation. An approach for developing and evaluating an intervention for smoking cessation is presented along with a measurement tool. Methods: A literature review reifying the MTM of health behavior change for smoking cessation has been presented. An instrument designed to measure constructs of MTM and associated smoking cessation behavior has been developed. Results: The instrument developed is available for validation, reliability and prediction study pertaining to smoking cessation. The intervention is available for testing in a randomized control trial involving smokers. Conclusion: MTM is a robust theory that holds promise for testing and application to smoking cessation.

  5. Application of advanced structure to multi-tone mask for FPD process

    NASA Astrophysics Data System (ADS)

    Song, Jin-Han; Jeong, Jin-Woong; Kim, Kyu-Sik; Jeong, Woo-Gun; Yun, Sang-Pil; Lee, Dong-Heok; Choi, Sang-Soo

    2017-07-01

    In accordance with improvement of FPD technology, masks such as phase shift mask (PSM) and multi-tone mask (MTM) for a particular purpose also have been developed. Above all, the MTM consisted of more than tri-tone transmittance has a substantial advantage which enables to reduce the number of mask demand in FPD fabrication process contrast to normal mask of two-tone transmittance.[1,2] A chromium (Cr)-based MTM (Typically top type) is being widely employed because of convenience of etch process caused by its only Cr-based structure consisted of Cr absorber layer and Cr half-tone layer. However, the top type of Cr-based MTM demands two Cr sputtering processes after each layer etching process and writing process. For this reason, a different material from the Cr-based MTM is required for reduction of mask fabrication time and cost. In this study, we evaluate a MTM which has a structure combined Cr with molybdenum silicide (MoSi) to resolve the issues mentioned above. The MoSi which is demonstrated by integrated circuit (IC) process is a suitable material for MTM evaluation. This structure could realize multi-transmittance in common with the Cr-based MTM. Moreover, it enables to reduce the number of sputtering process. We investigate a optimized structure upon consideration of productivity along with performance such as critical dimension (CD) variation and transmittance range of each structure. The transmittance is targeted at h-line wavelength (405 nm) in the evaluation. Compared with Cr-based MTM, the performances of all Cr-/MoSi-based MTMs are considered.

  6. Oscillatory modes of extended Nile River records (A.D. 622-1922)

    NASA Astrophysics Data System (ADS)

    Kondrashov, D.; Feliks, Y.; Ghil, M.

    2005-05-01

    The historical records of the low- and high-water levels of the Nile River are among the longest climatic records that have near-annual resolution. There are few gaps in the first part of the records (A.D. 622-1470) and larger gaps later (A.D. 1471-1922). We apply advanced spectral methods, Singular-Spectrum Analysis (SSA) and the Multi-Taper Method (MTM), to fill the gaps and to locate interannual and interdecadal periodicities. The gap filling uses a novel, iterative version of SSA. Our analysis reveals several statistically significant features of the records: a nonlinear, data-adaptive trend that includes a 256-year cycle, a quasi-quadriennial (4.2-year) and a quasi-biennial (2.2-year) mode, as well as additional periodicities of 64, 19, 12, and, most strikingly, 7 years. The quasi-quadriennial and quasi-biennial modes support the long-established connection between the Nile River discharge and the El-Niño/Southern Oscillation (ENSO) phenomenon in the Indo-Pacific Ocean. The longest periods might be of astronomical origin. The 7-year periodicity, possibly related to the biblical cycle of lean and fat years, seems to be due to North Atlantic influences.

  7. Spatial-frequency variability of the eddy kinetic energy in the South Atlantic Ocean

    NASA Astrophysics Data System (ADS)

    Cecilio, C. M.; Gherardi, D. F.; Souza, R.; Correa-Ramirez, M.

    2013-05-01

    In the South Atlantic Ocean (SAO) part of the inter-oceanic flow is accomplished through the issuance of anticyclonic eddies by the Agulhas Retroflection. This region, known as Agulhas Leakage (AL), is responsible by the intermittent shedding of eddies in the SAO. The propagation of these eddies into the SAO induces wave processes that allows the interaction between modes of variability of different basins, ranging from high to low frequency. Modelling studies suggests that the Indian-Atlantic inter-ocean exchange is strongly related to the structure of the wind field, in particular with the position of the maximum Southern Hemisphere westerly winds. This study aims to investigate the variations of the large-scale and regional mesoscale eddy field over the SAO using a frequency domain technique, Multiple Taper Method with Singular Value Decomposition (MTM-SVD). The MTM-SVD approach is applied to examine the individual and joint spatiotemporal variability modes of eddy kinetic energy (EKE) and winds stress. The EKE is estimated from geostrophic velocity anomalies data distributed by Aviso and winds stress from winds dataset of Cross-Calibrated Multi-Platform (CCMP) project from PO.DAAC. The impact of the AL in the SAO, was assessed first for the entire region and subsequently applied in the regions of higher mesoscale activity, which are the Brazil-Malvinas Confluence (BMC), the AL, and the Brazilian Current (BC) region. The results of local fractional variance (LFV) of EKE obtained by the MTM-SVD method show a strong significant annual variability in SAO and BC region while in BMC and in AL this frequency is weaker. In the most energetic mesoscale activity regions (BMC and AL) the pattern of variability is distinct. In the BMC region the interannual variability is dominated while in the AL region the most part of variability is associated by high frequency. The joint LFV spectrum of wind and EKE show an out-of-phase relationship between the AL region and BMC region in the interannual frequencies (3 to 5 years). The dominant frequencies can be seen in 1,5 to 3 years period band and in the intrasazonal frequencies, 0,3 to 0,5 years. The results suggests that the EKE variability patterns are different in the SAO wich might be related to the influence of eddies from AL.

  8. Nonlinear Dynamics, Poor Data, and What to Make of Them?

    NASA Astrophysics Data System (ADS)

    Ghil, M.; Zaliapin, I. V.

    2005-12-01

    The analysis of univariate or multivariate time series provides crucial information to describe, understand, and predict variability in the geosciences. The discovery and implementation of a number of novel methods for extracting useful information from time series has recently revitalized this classical field of study. Considerable progress has also been made in interpreting the information so obtained in terms of dynamical systems theory. In this talk we will describe the connections between time series analysis and nonlinear dynamics, discuss signal-to-noise enhancement, and present some of the novel methods for spectral analysis. These fall into two broad categories: (i) methods that try to ferret out regularities of the time series; and (ii) methods aimed at describing the characteristics of irregular processes. The former include singular-spectrum analysis (SSA), the multi-taper method (MTM), and the maximum-entropy method (MEM). The various steps, as well as the advantages and disadvantages of these methods, will be illustrated by their application to several important climatic time series, such as the Southern Oscillation Index (SOI), paleoclimatic time series, and instrumental temperature time series. The SOI index captures major features of interannual climate variability and is used extensively in its prediction. The other time series cover interdecadal and millennial time scales. The second category includes the calculation of fractional dimension, leading Lyapunov exponents, and Hurst exponents. More recently, multi-trend analysis (MTA), binary-decomposition analysis (BDA), and related methods have attempted to describe the structure of time series that include both regular and irregular components. Within the time available, I will try to give a feeling for how these methods work, and how well.

  9. Temporal and Periodic Variations of Sunspot Counts in Flaring and Non-Flaring Active Regions

    NASA Astrophysics Data System (ADS)

    Kilcik, A.; Yurchyshyn, V.; Donmez, B.; Obridko, V. N.; Ozguc, A.; Rozelot, J. P.

    2018-04-01

    We analyzed temporal and periodic variations of sunspot counts (SSCs) in flaring (C-, M-, or X-class flares), and non-flaring active regions (ARs) for nearly three solar cycles (1986 through 2016). Our main findings are as follows: i) temporal variations of monthly means of the daily total SSCs in flaring and non-flaring ARs behave differently during a solar cycle and the behavior varies from one cycle to another; during Solar Cycle 23 temporal SSC profiles of non-flaring ARs are wider than those of flaring ARs, while they are almost the same during Solar Cycle 22 and the current Cycle 24. The SSC profiles show a multi-peak structure and the second peak of flaring ARs dominates the current Cycle 24, while the difference between peaks is less pronounced during Solar Cycles 22 and 23. The first and second SSC peaks of non-flaring ARs have comparable magnitude in the current solar cycle, while the first peak is nearly absent in the case of the flaring ARs of the same cycle. ii) Periodic variations observed in the SSCs profiles of flaring and non-flaring ARs derived from the multi-taper method (MTM) spectrum and wavelet scalograms are quite different as well, and they vary from one solar cycle to another. The largest detected period in flaring ARs is 113± 1.6 days while we detected much longer periodicities (327± 13, 312 ± 11, and 256± 8 days) in the non-flaring AR profiles. No meaningful periodicities were detected in the MTM spectrum of flaring ARs exceeding 55± 0.7 days during Solar Cycles 22 and 24, while a 113± 1.3 days period was detected in flaring ARs of Solar Cycle 23. For the non-flaring ARs the largest detected period was only 31± 0.2 days for Cycle 22 and 72± 1.3 days for the current Cycle 24, while the largest measured period was 327± 13 days during Solar Cycle 23.

  10. Use of three-point taper systems in timber cruising

    Treesearch

    James W. Flewelling; Richard L. Ernst; Lawrence M. Raynes

    2000-01-01

    Tree volumes and profiles are often estimated as functions of total height and DBH. Alternative estimators include form-class methods, importance sampling, the centroid method, and multi-point profile (taper) estimation systems; all of these require some measurement or estimate of upper stem diameters. The multi-point profile system discussed here allows for upper stem...

  11. [Shaping ability of multi-taper nickel-titanium files in simulated resin curved root canal].

    PubMed

    Luo, Hong-Xia; Huang, Ding-Ming; Jia, Liu-He; Luo, Shi-Gao; Gao, Xiao-Jie; Tan, Hong; Zhou, Xue-Dong

    2006-08-01

    To compare the shaping ability of ISO standard stainless steel K files and multi-taper ProTaper nickel-titanium files in simulated resin curved root canals. METHODS Thirty simulated resin root canals were randomly divided into three groups and prepared by stainless steel K files, hand ProTaper, rotary ProTaper, respectively. The amount of material removed from inner and outer wall and canal width after canal preparation was measured, while the canal curvature before and after canal preparation and canals aberrations were recorded. The stainless steel K files removed more material than hand ProTaper and rotary ProTaper at the outer side of apex and inner side of curvature (P < 0.05). The mean degree of straightening in stainless steel K files group was significantly bigger than in ProTaper group (P < 0.05). The canals prepared by ProTaper had no evident aberration. The shaping ability of ProTaper is better than stainless steel K files.

  12. Evolution of the Climate Continuum from the Mid-Miocene Climatic Optimum to the Present

    NASA Astrophysics Data System (ADS)

    Aswasereelert, W.; Meyers, S. R.; Hinnov, L. A.; Kelly, D.

    2011-12-01

    The recognition of orbital rhythms in paleoclimate data has led to a rich understanding of climate evolution during the Neogene and Quaternary. In contrast, changes in stochastic variability associated with the transition from unipolar to bipolar glaciation have received less attention, although the stochastic component likely preserves key insights about climate. In this study, we seek to evaluate the dominance and character of stochastic climate energy since the Middle Miocene Climatic Optimum (~17 Ma). These analyses extend a previous study that suggested diagnostic stochastic responses associated with Northern Hemisphere ice sheet development during the Plio-Pleistocene (Meyers and Hinnov, 2010). A critical and challenging step necessary to conduct the work is the conversion of depth data to time data. We investigate climate proxy datasets using multiple time scale hypotheses, including depth-derived time scales, sedimentologic/geochemical "tuning", minimal orbital tuning, and comprehensive orbital tuning. To extract the stochastic component of climate, and also explore potential relationships between the orbital parameters and paleoclimate response, a number of approaches rooted in Thomson's (1982) multi-taper spectral method (MTM) are applied. Importantly, the MTM technique is capable of separating the spectral "continuum" - a measure of stochastic variability - from the deterministic periodic orbital signals (spectral "lines") preserved in proxy data. Time series analysis of the proxy records using different chronologic approaches allows us to evaluate the sensitivity of our conclusion about stochastic and deterministic orbital processes during the Middle Miocene to present. Moreover, comparison of individual records permits examination of the spatial dependence of the identified climate responses. Meyers, S.R., and Hinnov, L.A. (2010), Northern Hemisphere glaciation and the evolution of Plio-Pleistocene climate noise: Paleoceanography, 25, PA3207, doi:10.1029/2009PA001834. Thomson, D.J. (1982), Spectrum estimation and harmonic analysis: IEEE Proceedings, v. 70, p. 1055-1096.

  13. Evaluation of manometric temperature measurement, a process analytical technology tool for freeze-drying: part II measurement of dry-layer resistance.

    PubMed

    Tang, Xiaolin Charlie; Nail, Steven L; Pikal, Michael J

    2006-01-01

    The purpose of this work was to study the factors that may cause systematic errors in the manometric temperature measurement (MTM) procedure used to determine product dry-layer resistance to vapor flow. Product temperature and dry-layer resistance were obtained using MTM software installed on a laboratory freeze-dryer. The MTM resistance values were compared with the resistance values obtained using the "vial method." The product dry-layer resistances obtained by MTM, assuming fixed temperature difference (DeltaT; 2 degrees C), were lower than the actual values, especially when the product temperatures and sublimation rates were low, but with DeltaT determined from the pressure rise data, more accurate results were obtained. MTM resistance values were generally lower than the values obtained with the vial method, particularly whenever freeze-drying was conducted under conditions that produced large variations in product temperature (ie, low shelf temperature, low chamber pressure, and without thermal shields). In an experiment designed to magnify temperature heterogeneity, MTM resistance values were much lower than the simple average of the product resistances. However, in experiments where product temperatures were homogenous, good agreement between MTM and "vial-method" resistances was obtained. The reason for the low MTM resistance problem is the fast vapor pressure rise from a few "warm" edge vials or vials with low resistance. With proper use of thermal shields, and the evaluation of DeltaT from the data, MTM resistance data are accurate. Thus, the MTM method for determining dry-layer resistance is a useful tool for freeze-drying process analytical technology.

  14. Multi-Objective Optimization of Fleet-Level Metrics to Determine New System Design Requirements: An Application to Military Air Cargo Fuel Efficiency

    DTIC Science & Technology

    2014-04-30

    15, 2014 11:15 a.m. – 12: 45 p.m. Chair: Ken Mitchell Jr., Director, Research and Analysis, Defense Logistics Agency Mixture Distributions for...póåÉêÖó=Ñçê=fåÑçêãÉÇ=`Ü~åÖÉ= = - 276 - DOC = direct operating cost MTM /D = million ton-miles per day Op,i = indicates if airport i is the initial...highest level of modeled strategic airlift demand, required 32.7 million ton-miles per day ( MTM /D). MTM /D values for each type of aircraft are

  15. Decadal time scale variability recorded in the Quelccaya summit ice core δ18O isotopic ratio series and its relation with the sea surface temperature

    NASA Astrophysics Data System (ADS)

    Mélice, J. L.; Roucou, P.

    The spectral characteristics of the δ18O isotopic ratio time series of the Quelccaya ice cap summit core are investigated with the multi taper method (MTM), the singular spectrum analysis (SSA) and the wavelet transform (WT) techniques for the 500 y long 1485-1984 period. The most significant (at the 99.8% level) cycle according to the MTM F-test has a period centered at 14.4 y while the largest variance explaining oscillation according to the SSA technique has a period centered at 12.9 y. The stability over time of these periods is investigated by performing evolutive MTM and SSA on the 500 y long δ18O series with a 100 y wide moving window. It is shown that the cycles with largest amplitude and that the oscillations with largest extracting variance have corresponding periods aggregated around 13.5 y that are very stable over the period between 1485 and 1984. The WT of the same isotopic time series reveals the existence of a main oscillation around 12 y which are also very stable in time. The relation between the isotopic data at Quelccaya and the annual sea surface temperature (SST) field anomalies is then evaluated for the overlapping 1919-1984 period. Significant global correlation and significant coherency at 12.1 y are found between the isotopic series and the annual global sea surface temperature (GSST) series. Moreover, the correlation between the low (over 8 y) frequency component of the isotopic time series and the annual SST field point out significant values in the tropical North Atlantic. This region is characterized by a main SST variability at 12.8 y. The Quelccaya δ18O isotopic ratio series may therefore be considered as a good recorder of the tropical North Atlantic SSTs. This may be explained by the following mechanism: the water vapor amount evaporated by the tropical North Atlantic is function of the SST. So is the water vapor δ18O isotopic ratio. This water vapor is advected during the rainy season by northeast winds and precipitates at the Quelccaya summit with its tropical North Atlantic isotopic signature. It is also suggested from this described stability of the decadal time scale variability observed in the Quelccaya isotopic series, that the decadal time scale GSST variability was also stable during the last five centuries.

  16. Contingent Valuation and Pharmacists' Acceptable Levels of Compensation for Medication Therapy Management Services

    PubMed Central

    Wang, Junling; Hong, Song Hee

    2012-01-01

    Background Pharmacists' acceptable level of compensation for medication therapy management (MTM) services needs to be determined using various economic evaluation techniques. Objectives Using contingent valuation method, determine pharmacists' acceptable levels of compensation for MTM services. Methods A mailing survey was used to elicit Tennessee (US) pharmacists' acceptable levels of compensation for a 30-minute MTM session for a new patient with 2 medical conditions, 8 medications, and an annual drug cost of $2,000. Three versions of a series of double-bounded, closed-ended, binary discrete choice questions were asked of pharmacists for their willingness-to-accept (WTA) for an original monetary value ($30, $60, or $90) and then follow-up higher or lower value depending on their responses to the original value. A Kaplan-Meier approach was taken to analyze pharmacists' WTA, and Cox's proportional hazards model was used to examine the effects of pharmacist characteristics on their WTA. Results Three hundred and forty-eight pharmacists responded to the survey. Pharmacists' WTA for the given MTM session had a mean of $63.31 and median of $60. The proportions of pharmacists willing to accept $30, $60, and $90 for the given MTM session were 30.61%, 85.19%, and 91.01%, respectively. Pharmacists' characteristics had statistically significant association with their WTA rates. Conclusions Pharmacists' WTA for the given MTM session is higher than current Medicare MTM programs' compensation levels of $15 to $50 and patients' willingness-to-pay of less than $40. Besides advocating for higher MTM compensation levels by third-party payers, pharmacists also may need to charge patients to reach sufficient compensation levels for MTM services. PMID:22436583

  17. Applying Multi-Theory Model (MTM) of Health Behavior Change to Predict Water Consumption Instead of Sugar-Sweetened Beverages.

    PubMed

    Sharma, Manoj; Catalano, Hannah Priest; Nahar, Vinayak K; Lingam, Vimala C; Johnson, Paul; Ford, M Allison

    2017-02-25

    A substantial proportion of college students to not drink enough water and consume sugar-sweetened beverages (SSBs). Consumption of SSBs is associated with weight gain, obesity, type 2 diabetes mellitus, dental carries, and increased risk for cardiovascular disease. Hence, the purpose of this study was to use the multi-theory model (MTM) in predicting initiation and sustenance of plain water consumption instead of sugar-sweetened beverages among college students. A cross-sectional study. In this cross-sectional study, a 37-item valid and reliable MTM-based survey was administered to college students in 2016 via Qualtrics at a large public university in the Southeastern United States. Overall, 410 students responded to the survey; of those, 174 were eligible for the study and completed it. Stepwise multiple regression analysis revealed that 61.8% of the variance in the initiation of drinking plain water instead of SSBs was explained by behavioral confidence (P<0.001) and changes in the physical environment (P<0.001). Further, 58.3% of the variance in the sustenance of drinking plain water instead of SSBs was explained by emotional transformation (P<0.001) and practice for change (P=0.001). Multi-theory model of health behavior change is a robust theory for predicting plain water consumption instead of SSBs in college students. Interventions should be developed based on this theory for this target population.

  18. Evaluation of manometric temperature measurement, a process analytical technology tool for freeze-drying: part I, product temperature measurement.

    PubMed

    Tang, Xiaolin; Nail, Steven L; Pikal, Michael J

    2006-02-10

    This study examines the factors that may cause systematic errors in the manometric temperature measurement (MTM) procedure used to evaluate product temperature during primary drying. MTM was conducted during primary drying using different vial loads, and the MTM product temperatures were compared with temperatures directly measured by thermocouples. To clarify the impact of freeze-drying load on MTM product temperature, simulation of the MTM vapor pressure rise was performed, and the results were compared with the experimental results. The effect of product temperature heterogeneity in MTM product temperature determination was investigated by comparing the MTM product temperatures with directly measured thermocouple product temperatures in systems differing in temperature heterogeneity. Both the simulated and experimental results showed that at least 50 vials (5 mL) were needed to give sufficiently rapid pressure rise during the MTM data collection period (25 seconds) in the freeze dryer, to allow accurate determination of the product temperature. The product temperature is location dependent, with higher temperature for vials on the edge of the array and lower temperature for the vials in the center of the array. The product temperature heterogeneity is also dependent upon the freeze-drying conditions. In product temperature heterogeneous systems, MTM measures a temperature close to the coldest product temperature, even if only a small fraction of the samples have the coldest product temperature. The MTM method is valid even at very low product temperature (-45 degrees C).

  19. Evaluation of manometric temperature measurement, a process analytical technology tool for freeze-drying: Part I, product temperature measurement.

    PubMed

    Tang, Xiaolin; Nail, Steven L; Pikal, Michael J

    2006-03-01

    This study examines the factors that may cause systematic errors in the manometric temperature measurement (MTM) procedure used to evaluate product temperature during primary drying. MTM was conducted during primary drying using different vial loads, and the MTM product temperatures were compared with temperatures directly measured by thermocouples. To clarify the impact of freeze-drying load on MTM product temperatures, simulation of the MTM vapor pressure rise was performed, and the results were compared with the experimental results. The effect of product temperature heterogeneity in MTM product temperature determination was investigated by comparing the MTM product temperatures with directly measured thermocouple product temperatures in systems differing in temperature heterogeneity. Both the simulated and experimental results showed that at least 50 vials (5 mL) were needed to give sufficiently rapid pressure rise during the MTM data collection period (25 seconds) in the freeze dryer, to allow accurate determination of the product temperature. The product temperature is location dependent, with higher temperature for vials on the edge of the array and lower temperature for the vials in the center of the array. The product temperature heterogeneity is also dependent upon the freeze-drying conditions. In product temperature heterogeneous systems, MTM measures a temperature close to the coldest product temperature, even, if only a small fraction of the samples have the coldest product temperature. The MTM method is valid even at very low product temperature (-45°C).

  20. Analytical performance bounds for multi-tensor diffusion-MRI.

    PubMed

    Ahmed Sid, Farid; Abed-Meraim, Karim; Harba, Rachid; Oulebsir-Boumghar, Fatima

    2017-02-01

    To examine the effects of MR acquisition parameters on brain white matter fiber orientation estimation and parameter of clinical interest in crossing fiber areas based on the Multi-Tensor Model (MTM). We compute the Cramér-Rao Bound (CRB) for the MTM and the parameter of clinical interest such as the Fractional Anisotropy (FA) and the dominant fiber orientations, assuming that the diffusion MRI data are recorded by a multi-coil, multi-shell acquisition system. Considering the sum-of-squares method for the reconstructed magnitude image, we introduce an approximate closed-form formula for Fisher Information Matrix that has the simplicity and easy interpretation advantages. In addition, we propose to generalize the FA and the mean diffusivity to the multi-tensor model. We show the application of the CRB to reduce the scan time while preserving a good estimation precision. We provide results showing how the increase of the number of acquisition coils compensates the decrease of the number of diffusion gradient directions. We analyze the impact of the b-value and the Signal-to-Noise Ratio (SNR). The analysis shows that the estimation error variance decreases with a quadratic rate with the SNR, and that the optimum b-values are not unique but depend on the target parameter, the context, and eventually the target cost function. In this study we highlight the importance of choosing the appropriate acquisition parameters especially when dealing with crossing fiber areas. We also provide a methodology for the optimal tuning of these parameters using the CRB. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Testing multi-theory model (MTM) in predicting initiation and sustenance of physical activity behavior among college students

    PubMed Central

    Nahar, Vinayak K.; Sharma, Manoj; Catalano, Hannah Priest; Ickes, Melinda J.; Johnson, Paul; Ford, M. Allison

    2016-01-01

    Background: Most college students do not adequately participate in enough physical activity (PA) to attain health benefits. A theory-based approach is critical in developing effective interventions to promote PA. The purpose of this study was to examine the utility of the newly proposed multi-theory model (MTM) of health behavior change in predicting initiation and sustenance of PA among college students. Methods: Using a cross-sectional design, a valid and reliable survey was administered in October 2015 electronically to students enrolled at a large Southern US University. The internal consistency Cronbach alphas of the subscales were acceptable (0.65-0.92). Only those who did not engage in more than 150 minutes of moderate to vigorous intensity aerobic PA during the past week were included in this study. Results: Of the 495 respondents, 190 met the inclusion criteria of which 141 completed the survey. The majority of participants were females (72.3%) and Caucasians (70.9%). Findings of the confirmatory factor analysis (CFA) confirmed construct validity of subscales (initiation model: χ2 = 253.92 [df = 143], P < 0.001, CFI = 0.91, RMSEA = 0.07, SRMR = 0.07; sustenance model: χ2= 19.40 [df = 22], P < 0.001, CFI = 1.00, RMSEA = 0.00, SRMR = 0.03). Multivariate regression analysis showed that 26% of the variance in the PA initiation was explained by advantages outweighing disadvantages, behavioral confidence, work status, and changes in physical environment. Additionally, 29.7% of the variance in PA sustenance was explained by emotional transformation, practice for change, and changes in social environment. Conclusion: Based on this study’s findings, MTM appears to be a robust theoretical framework for predicting PA behavior change. Future research directions and development of suitable intervention strategies are discussed. PMID:27386419

  2. Trends in Medicare Part D Medication Therapy Management Eligibility Criteria

    PubMed Central

    Wang, Junling; Shih, Ya-Chen Tina; Qin, Yolanda; Young, Theo; Thomas, Zachary; Spivey, Christina A.; Solomon, David K.; Chisholm-Burns, Marie

    2015-01-01

    Background To increase the enrollment rate of medication therapy management (MTM) programs in Medicare Part D plans, the US Centers for Medicare & Medicaid Services (CMS) lowered the allowable eligibility thresholds based on the number of chronic diseases and Part D drugs for Medicare Part D plans for 2010 and after. However, an increase in MTM enrollment rates has not been realized. Objectives To describe trends in MTM eligibility thresholds used by Medicare Part D plans and to identify patterns that may hinder enrollment in MTM programs. Methods This study analyzed data extracted from the Medicare Part D MTM Programs Fact Sheets (2008–2014). The annual percentages of utilizing each threshold value of the number of chronic diseases and Part D drugs, as well as other aspects of MTM enrollment practices, were analyzed among Medicare MTM programs that were established by Medicare Part D plans. Results For 2010 and after, increased proportions of Medicare Part D plans set their eligibility thresholds at the maximum numbers allowable. For example, in 2008, 48.7% of Medicare Part D plans (N = 347:712) opened MTM enrollment to Medicare beneficiaries with only 2 chronic disease states (specific diseases varied between plans), whereas the other half restricted enrollment to patients with a minimum of 3 to 5 chronic disease states. After 2010, only approximately 20% of plans opened their MTM enrollment to patients with 2 chronic disease states, with the remaining 80% restricting enrollment to patients with 3 or more chronic diseases. Conclusion The policy change by CMS for 2010 and after is associated with increased proportions of plans setting their MTM eligibility thresholds at the maximum numbers allowable. Changes to the eligibility thresholds by Medicare Part D plans might have acted as a barrier for increased MTM enrollment. Thus, CMS may need to identify alternative strategies to increase MTM enrollment in Medicare plans. PMID:26380030

  3. Potential Health Implications of the MTM Eligibility Criteria in the Affordable Care Act Across Racial and Ethnic Groups

    PubMed Central

    Wang, Junling; Qiao, Yanru; Tina Shih, Ya-Chen; Jamison, JoEllen Jarrett; Spivey, Christina A.; Wan, Jim Y.; White-Means, Shelley I.; Dagogo-Jack, Samuel; Cushman, William C.; Chisholm-Burns, Marie

    2015-01-01

    Background The Medicare Prescription Drug, Improvement, and Modernization Act (MMA) requires Part D plans to establish programs to provide medication therapy management (MTM) services starting from 2006. MTM services have been found to improve patient outcomes from pharmacotherapy, reduce emergency room visits and hospitalizations, and reduce health care costs in a cost-effective fashion. However, previous research found that Non-Hispanic Blacks (Blacks) and Hispanics may be less likely to be eligible for MTM services than Non-Hispanic Whites (Whites) among the Medicare population according to current Medicare MTM eligibility criteria. This is because the Medicare MTM eligibility criteria are predominantly based on medication utilization and costs, while Blacks and Hispanics tend to use fewer prescription medications and incur lower prescription medication costs. The Patient Protection and Affordable Care Act (PPACA) laid out a set of MTM eligibility criteria for eligible entities to target patients for MTM services: “(1) take 4 or more prescribed medications …; (2) take any ‘high risk’ medications; (3) have 2 or more chronic diseases… or (4) have undergone a transition of care, or other factors… that are likely to create a high risk of medication-related problems.” Objectives This study aimed to examine (1) racial/ethnic disparities in meeting the eligibility criteria for MTM services in PPACA among the Medicare population; and (2) whether there would be greater disparities in health and economic outcomes among MTM-ineligible than MTM-eligible groups. (If so, the PPACA MTM eligibility criteria may aggravate existing disparities.) Methods This was a retrospective cross-sectional analysis of Medicare Current Beneficiaries Survey (MCBS; 2007–2008). To determine medication characteristics, the Food and Drug Administration’s Electronic Orange Book was also used. Proportions of population eligible for MTM services based on the PPACA MTM eligibility criteria were compared across racial and ethnic groups using a chi-square test; a logistic regression model was used to adjust for population socio-demographic and health characteristics. Health and economic outcomes examined included health status (self-perceived good health status, number of chronic diseases, activities of daily living or ADLs, and instrumental activities of daily living or IADLs), health services utilization and costs (physician visits, emergency room visits, and total health care costs), and medication utilization patterns (generic dispensing ratio). To determine difference in disparities across MTM eligibility categories, difference-in-differences regressions of various functional forms were employed depending on the nature of the dependent variables. Interaction terms between the dummy variables for minority groups (e.g., Blacks or Hispanics) and MTM eligibility were included to test whether disparity patterns varied between MTM-ineligible and MTM-eligible individuals. Results The sample consisted of 12,966 Medicare beneficiaries, of which 11,161 were White, 930 were Black and 875 were Hispanic. Of the study sample, 9,992 Whites (86.4%), 825 Blacks (86.3%) and 733 Hispanics (80.6%) were eligible for MTM. The difference between Whites and Hispanics was significant (P<0.05) and the difference between Whites and Blacks were not significant (P>0.05). In multivariate analyses, significant disparity in eligibility for MTM services was found only between Hispanics and Whites (OR = 0.59; 95% CI = 0.43–0.82) but not between Blacks and Whites (OR=0.78; 95% CI=0.55–1.09). Disparities were greater among the MTM-ineligible than the MTM-eligible populations in self-perceived health status, ADLs, and IADLs for both Blacks and Hispanics compared with Whites. When analyzing number of chronic conditions, number and costs of physician visits and total healthcare costs, this study found lower racial and ethnic disparities among the non-eligible population than the eligible population. Conclusion Hispanics would be significantly less likely than Whites to qualify for MTM eligibility among the Medicare population according to the MTM eligibility criteria stipulated in PPACA. The PPACA MTM eligibility criteria may aggravate existing racial and ethnic disparities in health status but may remediate racial and ethnic disparities in health services utilization. Alternative MTM eligibility criteria other than PPACA MTM eligibility criteria may be needed to improve the efficiency and equity of access to Medicare Part D MTM programs. PMID:26521111

  4. 76 FR 20369 - Notice of Invitation-Coal Exploration License Applications MTM 101687 and MTM 101688

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-12

    ... DEPARTMENT OF THE INTERIOR Bureau of Land Management [LLMT921000-11-L13200000-EL0000-P; MTM 101687-MTM 101688] Notice of Invitation-Coal Exploration License Applications MTM 101687 and MTM 101688..., Wyoming. Such written notice must refer to serial numbers MTM 101687 or MTM 101688. ADDRESSES: The...

  5. Developing a dashboard for benchmarking the productivity of a medication therapy management program.

    PubMed

    Umbreit, Audrey; Holm, Emily; Gander, Kelsey; Davis, Kelsie; Dittrich, Kristina; Jandl, Vanda; Odell, Laura; Sweeten, Perry

    To describe a method for internal benchmarking of medication therapy management (MTM) pharmacist activities. Multisite MTM pharmacist practices within an integrated health care system. MTM pharmacists are located within primary care clinics and provide medication management through collaborative practice. MTM pharmacist activity is grouped into 3 categories: direct patient care, nonvisit patient care, and professional activities. MTM pharmacist activities were tracked with the use of the computer-based application Pharmacist Ambulatory Resource Management System (PhARMS) over a 12-month period to measure growth during a time of expansion. A total of 81% of MTM pharmacist time was recorded. A total of 1655.1 hours (41%) was nonvisit patient care, 1185.2 hours (29%) was direct patient care, and 1190.4 hours (30%) was professional activities. The number of patient visits per month increased during the study period. There were 1496 direct patient care encounters documented. Of those, 1051 (70.2%) were face-to-face visits, 257 (17.2%) were by telephone, and 188 (12.6%) were chart reviews. Nonvisit patient care and professional activities also increased during the period. PhARMS reported MTM pharmacist activities and captured nonvisit patient care work not tracked elsewhere. Internal benchmarking data proved to be useful for justifying increases in MTM pharmacist personnel resources. Reviewing data helped to identify best practices from high-performing sites. Limitations include potential for self-reporting bias and lack of patient outcomes data. Implementing PhARMS facilitated internal benchmarking of patient care and nonpatient care activities in a regional MTM program. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  6. 75 FR 30060 - Notice of Proposed Reinstatement of Terminated Oil and Gas Leases MTM 97526 and MTM 97527, Montana

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-28

    ... DEPARTMENT OF THE INTERIOR Bureau of Land Management [LLMT922200-10-L13100000-FI0000-P; MTM 97526 and MTM 97527] Notice of Proposed Reinstatement of Terminated Oil and Gas Leases MTM 97526 and MTM... MTM 97526 and MTM 97527, Richland County, Montana. The lessee paid the required rental accruing from...

  7. Contingent valuation and pharmacists' acceptable levels of compensation for medication therapy management services.

    PubMed

    Wang, Junling; Hong, Song Hee

    2015-01-01

    Pharmacists' acceptable level of compensation for medication therapy management (MTM) services needs to be determined using various economic evaluation techniques. Using contingent valuation method, determine pharmacists' acceptable levels of compensation for MTM services. A mailing survey was used to elicit Tennessee (U.S.) pharmacists' acceptable levels of compensation for a 30-minute MTM session for a new patient with 2 medical conditions, 8 medications, and an annual drug cost of $2000. Three versions of a series of double-bounded, closed-ended, binary discrete choice questions were asked of pharmacists for their willingness to accept (WTA) for an original monetary value ($30, $60, or $90) and then follow-up higher or lower value depending on their responses to the original value. A Kaplan-Meier approach was taken to analyze pharmacists' WTA, and Cox's proportional hazards model was used to examine the effects of pharmacist characteristics on their WTA. Three hundred and forty-eight pharmacists responded to the survey. Pharmacists' WTA for the given MTM session had a mean of $63.31 and median of $60. The proportions of pharmacists willing to accept $30, $60, and $90 for the given MTM session were 30.61%, 85.19%, and 91.01%, respectively. Pharmacists' characteristics had statistically significant association with their WTA rates. Pharmacists' WTA for the given MTM session is higher than current Medicare MTM programs' compensation levels of $15-$50 and patients' willingness to pay of less than $40. Besides advocating for higher MTM compensation levels by third-party payers, pharmacists also may need to charge patients to reach sufficient compensation levels for MTM services. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Evidence for a possible modern and mid-Holocene solar influence on climate from Lake Titicaca, South America

    NASA Astrophysics Data System (ADS)

    Theissen, K. M.; Dunbar, R. B.

    2005-12-01

    In tropical regions, there are few paleoclimate archives with the necessary resolution to investigate climate variability at interannual-to-decadal timescales prior to the onset of the instrumental record. Interannual variability associated with the El Niño Southern Oscillation (ENSO) is well documented in the instrumental record and the importance of the precessional forcing of millennial variability has been established in studies of tropical paleoclimate records. In contrast, decade-to-century variability is still poorly understood. Here, we examine interannual to decadal variability in the northern Altiplano of South America using digital image analysis of a floating interval of varved sediments of middle Holocene age (~6160-6310 yr BP) from Lake Titicaca. Multi-taper method (MTM) and wavelet frequency-domain analyses were performed on a time series generated from a gray-scaled digital image of the mm-thick laminations. Our results indicate significant power at a decadal periodicity (10-12 years) associated with the Schwabe cycle of solar activity. Frequency-domain analysis also indicates power at 2-2.5 year periodicities associated with ENSO. Similarly, spectral analysis of a 75 year instrumental record of Titicaca lake level shows significant power at both solar and ENSO periodicities. Although both of the examined records are short, our results imply that during both the mid-Holocene and modern times, solar and ENSO variability may have contributed to high frequency climate fluctuations over the northern Altiplano. We suspect that solar influence on large-scale atmospheric circulation features may account for the decadal variability in the mid-Holocene and present-day water balance of the Altiplano.

  9. Fiber up-tapering and down-tapering for low-loss coupling between anti-resonant hollow-core fiber and solid-core fiber

    NASA Astrophysics Data System (ADS)

    Zhang, Naiqian; Wang, Zefeng; Xi, Xiaoming

    2017-10-01

    In this paper, we demonstrate a novel method for the low-loss coupling between solid-core multi-mode fibers (MMFs) and anti-resonant hollow-core fibers (AR-HCFs). The core/cladding diameter of the MMF is 50/125μm and the mode field diameter of the AR-HCFs are 33.3μm and 71.2μm of the ice-cream type AR-HCFs and the non-node type ARHCFs, respectively. In order to match the mode field diameters of these two specific AR-HCFs, the mode field diameter of the MMFs is increased or decreased by up-tapering or down-tapering the MMFs. Then, according to the principle of coupled fiber mode matching, the optimal diameter of tapered fiber for low-loss coupling is calculated. Based on beam propagation method, the calculated coupling losses without tapering process are 0.31dB and 0.89dB, respectively for a MMF-HCF-MMF structure of the ice-cream type AR-HCFs and the non-node type AR-HCFs. These values can be reduced to 0.096dB and 0.047dB when the outer diameters of the MMF are down-tapered to 116μm and up-tapered to 269μm, respectively. What's more, these results can also be verified by existing experiments.

  10. A double-taper optical fiber-based radiation wave other than evanescent wave in all-fiber immunofluorescence biosensor for quantitative detection of Escherichia coli O157:H7.

    PubMed

    Zhang, Zhonghuan; Hua, Fei; Liu, Ting; Zhao, Yong; Li, Jun; Yang, Ruifu; Yang, Changxi; Zhou, Lei

    2014-01-01

    Cylindrical or taper-and-cylinder combination optical fiber probe based on evanescent wave has been widely used for immunofluorescence biosensor to detect various analytes. In this study, in contrast to the contradiction between penetration depth and analyte diameter of optical fiber probe-based evanescent wave, we demonstrate that double-taper optical fiber used in a radiation wave-based all-fiber immunofluorescence biosensor (RWAIB) can detect micron-scale analytes using Escherichia coli O157:H7 as representative target. Finite-difference time-domain method was used to compare the properties of evanescent wave and radiation wave (RW). Ray-tracing model was formulated to optimize the taper geometry of the probe. Based on a commercial multi-mode fiber, a double-taper probe was fabricated and connected with biosensor through a "ferrule connector" optical fiber connector. The RWAIB configuration was accomplished using commercial multi-mode fibers and fiber-based devices according to the "all-fiber" method. The standard sample tests revealed that the sensitivity of the proposed technique for E. coli O157:H7 detection was 10(3) cfu · mL(-1). Quantitation could be achieved within the concentration range of 10(3) cfu · mL(-1) to 107 cfu · mL(-1). No non-specific recognition to ten kinds of food-borne pathogens was observed. The results demonstrated that based on the double-taper optical fiber RWAIB can be used for the quantitative detection of micron-scale targets, and RW sensing is an alternative for traditional evanescent wave sensing during the fabrication of fiber-optic biosensors.

  11. Minutia Tensor Matrix: A New Strategy for Fingerprint Matching

    PubMed Central

    Fu, Xiang; Feng, Jufu

    2015-01-01

    Establishing correspondences between two minutia sets is a fundamental issue in fingerprint recognition. This paper proposes a new tensor matching strategy. First, the concept of minutia tensor matrix (simplified as MTM) is proposed. It describes the first-order features and second-order features of a matching pair. In the MTM, the diagonal elements indicate similarities of minutia pairs and non-diagonal elements indicate pairwise compatibilities between minutia pairs. Correct minutia pairs are likely to establish both large similarities and large compatibilities, so they form a dense sub-block. Minutia matching is then formulated as recovering the dense sub-block in the MTM. This is a new tensor matching strategy for fingerprint recognition. Second, as fingerprint images show both local rigidity and global nonlinearity, we design two different kinds of MTMs: local MTM and global MTM. Meanwhile, a two-level matching algorithm is proposed. For local matching level, the local MTM is constructed and a novel local similarity calculation strategy is proposed. It makes full use of local rigidity in fingerprints. For global matching level, the global MTM is constructed to calculate similarities of entire minutia sets. It makes full use of global compatibility in fingerprints. Proposed method has stronger description ability and better robustness to noise and nonlinearity. Experiments conducted on Fingerprint Verification Competition databases (FVC2002 and FVC2004) demonstrate the effectiveness and the efficiency. PMID:25822489

  12. Refractive index sensors based on the fused tapered special multi-mode fiber

    NASA Astrophysics Data System (ADS)

    Fu, Xing-hu; Xiu, Yan-li; Liu, Qin; Xie, Hai-yang; Yang, Chuan-qing; Zhang, Shun-yang; Fu, Guang-wei; Bi, Wei-hong

    2016-01-01

    In this paper, a novel refractive index (RI) sensor is proposed based on the fused tapered special multi-mode fiber (SMMF). Firstly, a section of SMMF is spliced between two single-mode fibers (SMFs). Then, the SMMF is processed by a fused tapering machine, and a tapered fiber structure is fabricated. Finally, a fused tapered SMMF sensor is obtained for measuring external RI. The RI sensing mechanism of tapered SMMF sensor is analyzed in detail. For different fused tapering lengths, the experimental results show that the RI sensitivity can be up to 444.517 81 nm/RIU in the RI range of 1.334 9—1.347 0. The RI sensitivity is increased with the increase of fused tapering length. Moreover, it has many advantages, including high sensitivity, compact structure, fast response and wide application range. So it can be used to measure the solution concentration in the fields of biochemistry, health care and food processing.

  13. New results on the mid-latitude midnight temperature maximum

    NASA Astrophysics Data System (ADS)

    Mesquita, Rafael L. A.; Meriwether, John W.; Makela, Jonathan J.; Fisher, Daniel J.; Harding, Brian J.; Sanders, Samuel C.; Tesema, Fasil; Ridley, Aaron J.

    2018-04-01

    Fabry-Perot interferometer (FPI) measurements of thermospheric temperatures and winds show the detection and successful determination of the latitudinal distribution of the midnight temperature maximum (MTM) in the continental mid-eastern United States. These results were obtained through the operation of the five FPI observatories in the North American Thermosphere Ionosphere Observing Network (NATION) located at the Pisgah Astronomic Research Institute (PAR) (35.2° N, 82.8° W), Virginia Tech (VTI) (37.2° N, 80.4° W), Eastern Kentucky University (EKU) (37.8° N, 84.3° W), Urbana-Champaign (UAO) (40.2° N, 88.2° W), and Ann Arbor (ANN) (42.3° N, 83.8° W). A new approach for analyzing the MTM phenomenon is developed, which features the combination of a method of harmonic thermal background removal followed by a 2-D inversion algorithm to generate sequential 2-D temperature residual maps at 30 min intervals. The simultaneous study of the temperature data from these FPI stations represents a novel analysis of the MTM and its large-scale latitudinal and longitudinal structure. The major finding in examining these maps is the frequent detection of a secondary MTM peak occurring during the early evening hours, nearly 4.5 h prior to the timing of the primary MTM peak that generally appears after midnight. The analysis of these observations shows a strong night-to-night variability for this double-peaked MTM structure. A statistical study of the behavior of the MTM events was carried out to determine the extent of this variability with regard to the seasonal and latitudinal dependence. The results show the presence of the MTM peak(s) in 106 out of the 472 determinable nights (when the MTM presence, or lack thereof, can be determined with certainty in the data set) selected for analysis (22 %) out of the total of 846 nights available. The MTM feature is seen to appear slightly more often during the summer (27 %), followed by fall (22 %), winter (20 %), and spring (18 %). Also seen is a northwestward propagation of the MTM signature with a latitude-dependent amplitude. This behavior suggests either a latitudinal dependence of thermosphere tidal dissipation or a night-to-night variation of the composition of the higher-order tidal modes that contribute to the production of the MTM peak at mid-latitudes. Also presented in this paper is the perturbation on the divergence of the wind fields, which is associated with the passage of each MTM peak analyzed with the 2-D interpolation.

  14. Tapered optical fiber tip probes based on focused ion beam-milled Fabry-Perot microcavities

    NASA Astrophysics Data System (ADS)

    André, Ricardo M.; Warren-Smith, Stephen C.; Becker, Martin; Dellith, Jan; Rothhardt, Manfred; Zibaii, M. I.; Latifi, H.; Marques, Manuel B.; Bartelt, Hartmut; Frazão, Orlando

    2016-09-01

    Focused ion beam technology is combined with dynamic chemical etching to create microcavities in tapered optical fiber tips, resulting in fiber probes for temperature and refractive index sensing. Dynamic chemical etching uses hydrofluoric acid and a syringe pump to etch standard optical fibers into cone structures called tapered fiber tips where the length, shape, and cone angle can be precisely controlled. On these tips, focused ion beam is used to mill several different types of Fabry-Perot microcavities. Two main cavity types are initially compared and then combined to form a third, complex cavity structure. In the first case, a gap is milled on the tapered fiber tip which allows the external medium to penetrate the light guiding region and thus presents sensitivity to external refractive index changes. In the second, two slots that function as mirrors are milled on the tip creating a silica cavity that is only sensitive to temperature changes. Finally, both cavities are combined on a single tapered fiber tip, resulting in a multi-cavity structure capable of discriminating between temperature and refractive index variations. This dual characterization is performed with the aid of a fast Fourier transform method to separate the contributions of each cavity and thus of temperature and refractive index. Ultimately, a tapered optical fiber tip probe with sub-standard dimensions containing a multi-cavity structure is projected, fabricated, characterized and applied as a sensing element for simultaneous temperature and refractive index discrimination.

  15. Characterising volcanic cycles at Soufriere Hills Volcano, Montserrat: Time series analysis of multi-parameter satellite data

    NASA Astrophysics Data System (ADS)

    Flower, Verity J. B.; Carn, Simon A.

    2015-10-01

    The identification of cyclic volcanic activity can elucidate underlying eruption dynamics and aid volcanic hazard mitigation. Whilst satellite datasets are often analysed individually, here we exploit the multi-platform NASA A-Train satellite constellation to cross-correlate cyclical signals identified using complementary measurement techniques at Soufriere Hills Volcano (SHV), Montserrat. In this paper we present a Multi-taper (MTM) Fast Fourier Transform (FFT) analysis of coincident SO2 and thermal infrared (TIR) satellite measurements at SHV facilitating the identification of cyclical volcanic behaviour. These measurements were collected by the Ozone Monitoring Instrument (OMI) and Moderate Resolution Imaging Spectroradiometer (MODIS) (respectively) in the A-Train. We identify a correlating cycle in both the OMI and MODIS data (54-58 days), with this multi-week feature attributable to episodes of dome growth. The 50 day cycles were also identified in ground-based SO2 data at SHV, confirming the validity of our analysis and further corroborating the presence of this cycle at the volcano. In addition a 12 day cycle was identified in the OMI data, previously attributed to variable lava effusion rates on shorter timescales. OMI data also display a one week (7-8 days) cycle attributable to cyclical variations in viewing angle resulting from the orbital characteristics of the Aura satellite. Longer period cycles possibly relating to magma intrusion were identified in the OMI record (102-, 121-, and 159 days); in addition to a 238-day cycle identified in the MODIS data corresponding to periodic destabilisation of the lava dome. Through the analysis of reconstructions generated from cycles identified in the OMI and MODIS data, periods of unrest were identified, including the major dome collapse of 20th May 2006 and significant explosive event of 3rd January 2009. Our analysis confirms the potential for identification of cyclical volcanic activity through combined analysis of satellite data, which would be of particular value at poorly monitored volcanic systems.

  16. Establishment and Implementation of a Required Medication Therapy Management Advanced Pharmacy Practice Experience

    PubMed Central

    Gilliam, Eric; Thompson, Megan; Vande Griend, Joseph

    2017-01-01

    Objective. To develop a community pharmacy-based medication therapy management (MTM) advanced pharmacy practice experience (APPE) that provides students with skills and knowledge to deliver entry-level pharmacy MTM services. Design. The University of Colorado Skaggs School of Pharmacy & Pharmaceutical Sciences (SSPPS) partnered with three community pharmacy chains to establish this three-week, required MTM APPE. Students completed the American Pharmacists Association MTM Certificate Course prior to entering the APPE. Students were expected to spend 90% or more of their time at this experience working on MTM interventions, using store MTM platforms. Assessment. All 151 students successfully completed this MTM APPE, and each received a passing evaluation from their preceptor. Preceptor evaluations of students averaged above four (entry-level practice) on a five-point Likert scale. The majority of students reported engagement in MTM services for more than 80% of the time on site. Students’ self-reporting of their ability to perform MTM interventions improved after participation in the APPE. Conclusion. The SSPPS successfully implemented a required MTM APPE, preparing students for entry-level delivery of MTM services. PMID:28381896

  17. Impact of passive and active promotional strategies on patient acceptance of medication therapy management services.

    PubMed

    Huet, Alison L; Frail, Caitlin K; Lake, Leslie M; Snyder, Margie E

    2015-01-01

    To assess the impact of passive and active promotional strategies on patient acceptance of medication therapy management (MTM) services, and to identify reasons for patient acceptance or refusal. Four promotional approaches were developed to offer MTM services to eligible patients, including letters and bag stuffers ("passive" approaches), and face-to-face offers and telephone calls ("active" approaches). Thirty pharmacies in a grocery store chain were randomized to one of the four approaches. Patient acceptance rates were compared among the four groups, and between active and passive approaches using hierarchical logistic regression techniques. Depending on their decision to accept or decline the service, patients were invited to take part in one of two brief telephone surveys. No significant differences were identified among the four promotional methods or between active and passive methods in the analyses. Patients' most frequent reasons for accepting MTM services were potential cost savings, review of how the medications were working, the expert opinion of the pharmacist, and education about medications. Patients' most frequent reasons for declining MTM services were that the participant already felt comfortable with their medications and felt their pharmacist provides these services on a regular basis. No significant difference was found among any of the four groups or between active or passive approaches. Further research is warranted to identify strategies for improving patient engagement in MTM services.

  18. A natural history study of X-linked myotubular myopathy

    PubMed Central

    Amburgey, Kimberly; Tsuchiya, Etsuko; de Chastonay, Sabine; Glueck, Michael; Alverez, Rachel; Nguyen, Cam-Tu; Rutkowski, Anne; Hornyak, Joseph; Beggs, Alan H.

    2017-01-01

    Objective: To define the natural history of X-linked myotubular myopathy (MTM). Methods: We performed a cross-sectional study that included an online survey (n = 35) and a prospective, 1-year longitudinal investigation using a phone survey (n = 33). Results: We ascertained data from 50 male patients with MTM and performed longitudinal assessments on 33 affected individuals. Consistent with existing knowledge, we found that MTM is a disorder associated with extensive morbidities, including wheelchair (86.7% nonambulant) and ventilator (75% requiring >16 hours of support) dependence. However, unlike previous reports and despite the high burden of disease, mortality was lower than anticipated (approximate rate 10%/y). Seventy-six percent of patients with MTM enrolled (mean age 10 years 11 months) were alive at the end of the study. Nearly all deaths in the study were associated with respiratory failure. In addition, the disease course was more stable than expected, with few adverse events reported during the prospective survey. Few non–muscle-related morbidities were identified, although an unexpectedly high incidence of learning disability (43%) was noted. Conversely, MTM was associated with substantial burdens on patient and caregiver daily living, reflected by missed days of school and lost workdays. Conclusions: MTM is one of the most severe neuromuscular disorders, with affected individuals requiring extensive mechanical interventions for survival. However, among study participants, the disease course was more stable than predicted, with more individuals surviving infancy and early childhood. These data reflect the disease burden of MTM but offer hope in terms of future therapeutic intervention. PMID:28842446

  19. Impact of live medication therapy management on cholesterol values in patients with cardiovascular disease.

    PubMed

    Thumar, Ricky; Zaiken, Kathy

    2014-01-01

    To compare the impact of clinical pharmacist (CP) recommendations through a live, primary care-based, medication therapy management (MTM) protocol on low-density-lipoprotein (LDL) cholesterol in patients who have cardiovascular disease (CVD) with standard, chart-review MTM. Patients with established CVD who were not at their LDL goal were identified and analyzed by either a chart-review MTM service or a live, one-on-one pharmacist-physician MTM service over a 6-month timeframe. For the chart-review MTM service, recommendations were communicated through an electronic medical record (EMR) that the physician and pharmacist had access to. Primary outcomes included mean LDL reduction from baseline, number of patients achieving their LDL goal, and percent of implemented CP recommendations. Mean LDL reduction from baseline in the chart-review MTM group and the live MTM group was 36 mg/dL ± 23.2 mg/dL (P = 0.001) and 62 mg/dL ± 28.3 mg/dL (P = 0.001), respectively. The difference between these two groups was statistically significant (P = 0.001). The chart-review MTM group had 30% of patients reach their LDL goal with 66.3% of CP recommendations implemented compared to 51.3% and 86.3% for the same parameters in the live MTM group (P = 0.006 and P = 0.003, respectively). Although both MTM services provide a significant LDL reduction from baseline in patients with CVD, live MTM provides significantly greater LDL reductions, implemented CP recommendations, and goal attainment than chart-review MTM. Thus, live MTM services are more effective than chart-review MTM services, at least within the clinics that these protocols were assessed for the purposes of this study.

  20. Chronic Cardiovascular Disease Mortality in Mountaintop Mining Areas of Central Appalachian States

    ERIC Educational Resources Information Center

    Esch, Laura; Hendryx, Michael

    2011-01-01

    Purpose: To determine if chronic cardiovascular disease (CVD) mortality rates are higher among residents of mountaintop mining (MTM) areas compared to mining and nonmining areas, and to examine the association between greater levels of MTM surface mining and CVD mortality. Methods: Age-adjusted chronic CVD mortality rates from 1999 to 2006 for…

  1. ENSO related variability in the Southern Hemisphere, 1948-2000

    NASA Astrophysics Data System (ADS)

    Ribera, Pedro; Mann, Michael E.

    2003-01-01

    The spatiotemporal evolution of Southern Hemisphere climate variability is diagnosed based on the use of the NCEP reanalysis (1948-2000) dataset. Using the MTM-SVD analysis method, significant narrowband variability is isolated from the multi-variate dataset. It is found that the ENSO signal exhibits statistically significant behavior at quasiquadrennial (3-6 yr) timescales for the full time-period. A significant quasibiennial (2-3 yr) timescales emerges only for the latter half of period. Analyses of the spatial evolution of the two reconstructed signals shed additional light on linkages between low and high-latitude Southern Hemisphere climate anomalies.

  2. Comparison of spinal manipulation methods and usual medical care for acute and subacute low back pain: a randomized clinical trial.

    PubMed

    Schneider, Michael; Haas, Mitchell; Glick, Ronald; Stevans, Joel; Landsittel, Doug

    2015-02-15

    Randomized controlled trial with follow-up to 6 months. This was a comparative effectiveness trial of manual-thrust manipulation (MTM) versus mechanical-assisted manipulation (MAM); and manipulation versus usual medical care (UMC). Low back pain (LBP) is one of the most common conditions seen in primary care and physical medicine practice. MTM is a common treatment for LBP. Claims that MAM is an effective alternative to MTM have yet to be substantiated. There is also question about the effectiveness of manipulation in acute and subacute LBP compared with UMC. A total of 107 adults with onset of LBP within the past 12 weeks were randomized to 1 of 3 treatment groups: MTM, MAM, or UMC. Outcome measures included the Oswestry LBP Disability Index (0-100 scale) and numeric pain rating (0-10 scale). Participants in the manipulation groups were treated twice weekly during 4 weeks; subjects in UMC were seen for 3 visits during this time. Outcome measures were captured at baseline, 4 weeks, 3 months, and 6 months. Linear regression showed a statistically significant advantage of MTM at 4 weeks compared with MAM (disability = -8.1, P = 0.009; pain = -1.4, P = 0.002) and UMC (disability = -6.5, P = 0.032; pain = -1.7, P < 0.001). Responder analysis, defined as 30% and 50% reductions in Oswestry LBP Disability Index scores revealed a significantly greater proportion of responders at 4 weeks in MTM (76%; 50%) compared with MAM (50%; 16%) and UMC (48%; 39%). Similar between-group results were found for pain: MTM (94%; 76%); MAM (69%; 47%); and UMC (56%; 41%). No statistically significant group differences were found between MAM and UMC, and for any comparison at 3 or 6 months. MTM provides greater short-term reductions in self-reported disability and pain scores compared with UMC or MAM. 2.

  3. Modeling the human MTM1 p.R69C mutation in murine Mtm1 results in exon 4 skipping and a less severe myotubular myopathy phenotype

    PubMed Central

    Pierson, Christopher R.; Dulin-Smith, Ashley N.; Durban, Ashley N.; Marshall, Morgan L.; Marshall, Jordan T.; Snyder, Andrew D.; Naiyer, Nada; Gladman, Jordan T.; Chandler, Dawn S.; Lawlor, Michael W.; Buj-Bello, Anna; Dowling, James J.; Beggs, Alan H.

    2012-01-01

    X-linked myotubular myopathy (MTM) is a severe neuromuscular disease of infancy caused by mutations of MTM1, which encodes the phosphoinositide lipid phosphatase, myotubularin. The Mtm1 knockout (KO) mouse has a severe phenotype and its short lifespan (8 weeks) makes it a challenge to use as a model in the testing of certain preclinical therapeutics. Many MTM patients succumb early in life, but some have a more favorable prognosis. We used human genotype–phenotype correlation data to develop a myotubularin-deficient mouse model with a less severe phenotype than is seen in Mtm1 KO mice. We modeled the human c.205C>T point mutation in Mtm1 exon 4, which is predicted to introduce the p.R69C missense change in myotubularin. Hemizygous male Mtm1 p.R69C mice develop early muscle atrophy prior to the onset of weakness at 2 months. The median survival period is 66 weeks. Histopathology shows small myofibers with centrally placed nuclei. Myotubularin protein is undetectably low because the introduced c.205C>T base change induced exon 4 skipping in most mRNAs, leading to premature termination of myotubularin translation. Some full-length Mtm1 mRNA bearing the mutation is present, which provides enough myotubularin activity to account for the relatively mild phenotype, as Mtm1 KO and Mtm1 p.R69C mice have similar muscle phosphatidylinositol 3-phosphate levels. These data explain the basis for phenotypic variability among human patients with MTM1 p.R69C mutations and establish the Mtm1 p.R69C mouse as a valuable model for the disease, as its less severe phenotype will expand the scope of testable preclinical therapies. PMID:22068590

  4. Incidence of Dentinal Crack after Root Canal Preparation by ProTaper Universal, Neolix and SafeSider Systems

    PubMed Central

    Harandi, Azadeh; Mirzaeerad, Sina; Mehrabani, Mahgol; Mahmoudi, Elham; Bijani, Ali

    2017-01-01

    Introduction: This study aimed to compare the incidence of dentinal crack formation by instrumentation with ProTaper Universal system (rotary, multi-file system), SafeSider (reciprocation movement, multi-file system) and Neolix (rotary, single-file system). Methods and Materials: In this in vitro study, 60 freshly extracted mandibular first molars were randomly divided into three experimental groups (n=15) and a control group containing unprepared teeth (n=15). Instrumentation in different groups was accomplished using either ProTaper, Neolix or SafeSider systems up to 25/0.08. The teeth were then sectioned at 3, 6 and 9 mm from the apex, and observed under a stereomicroscope for presence of dentinal cracks. Data were analyzed with Chi square test, Fisher’s exact test and Bonferroni correction. Results: Micro cracks were seen in all experimental groups (13.3% in ProTaper, 26.7% in SafeSider and 40% in Neolix). There was a significant difference between Neolix and the control groups in microcrack formation (P=0.042). Micro cracks mainly occurred in the coronal section (9 mm). No microcrack occurred in the control group. Conclusion: Neolix rotary single-file system caused more dentinal cracks compared to the unprepared roots. All the instrumentation systems increased the number of micro cracks compared to unprepared teeth. PMID:29225637

  5. "Photonic lantern" spectral filters in multi-core Fiber.

    PubMed

    Birks, T A; Mangan, B J; Díez, A; Cruz, J L; Murphy, D F

    2012-06-18

    Fiber Bragg gratings are written across all 120 single-mode cores of a multi-core optical Fiber. The Fiber is interfaced to multimode ports by tapering it within a depressed-index glass jacket. The result is a compact multimode "photonic lantern" filter with astrophotonic applications. The tapered structure is also an effective mode scrambler.

  6. Chronic cardiovascular disease mortality in mountaintop mining areas of central Appalachian states.

    PubMed

    Esch, Laura; Hendryx, Michael

    2011-01-01

    To determine if chronic cardiovascular disease (CVD) mortality rates are higher among residents of mountaintop mining (MTM) areas compared to mining and nonmining areas, and to examine the association between greater levels of MTM surface mining and CVD mortality. Age-adjusted chronic CVD mortality rates from 1999 to 2006 for counties in 4 Appalachian states where MTM occurs (N = 404) were linked with county coal mining data. Three groups of counties were compared: MTM, coal mining but not MTM, and nonmining. Covariates included smoking rate, rural-urban status, percent male population, primary care physician supply, obesity rate, diabetes rate, poverty rate, race/ethnicity rates, high school and college education rates, and Appalachian county. Linear regression analyses examined the association of mortality rates with mining in MTM areas and non-MTM areas and the association of mortality with quantity of surface coal mined in MTM areas. Prior to covariate adjustment, chronic CVD mortality rates were significantly higher in both mining areas compared to nonmining areas and significantly highest in MTM areas. After adjustment, mortality rates in MTM areas remained significantly higher and increased as a function of greater levels of surface mining. Higher obesity and poverty rates and lower college education rates also significantly predicted CVD mortality overall and in rural counties. MTM activity is significantly associated with elevated chronic CVD mortality rates. Future research is necessary to examine the socioeconomic and environmental impacts of MTM on health to reduce health disparities in rural coal mining areas. © 2011 National Rural Health Association.

  7. Sound Medication Therapy Management Programs, Version 2.0 with validation study.

    PubMed

    2008-01-01

    The Academy of Managed Care Pharmacy (AMCP, the Academy) contracted with the National Committee for Quality Assurance (NCQA) to conduct a field study to validate and assess the 2006 Sound Medication Therapy Management Programs, Version 1.0 document. Version 1.0 posits several principles of sound medication therapy management (MTM) programs: they (1) recruit patients whose data show they may need assistance with managing medications; (2) have health professionals who intervene with patients and their physicians to improve medication regimens; and (3) measure their results. The validation study determined the extent to which the principles identified in version 1.0 are incorporated in MTM programs. The method was designed to determine to what extent the important features and operational elements of sound MTM programs as described in version 1.0 are (1) acceptable and seen as comprehensive to users, (2) incorporated into MTM programs in the field, (3) reflective of the consensus group's intentions, and (4) in need of modification or updating. NCQA first conducted Phase One, in which NCQA gathered perspectives on the principles in the consensus document from a mixed group of stakeholders representing both providers and users of MTM programs. Phase Two involved a deeper analysis of existing programs related to the consensus document, in which NCQA conducted a Web-based survey of 20 varied MTM programs and conducted in-depth site visits with 5 programs. NCQA selected programs offered by a range of MTM-providing organizations -- health plans, pharmacy benefit management companies, disease management organizations, and stand-alone MTM providers. NCQA analyzed the results of both phases. The Phase Two survey asked specific questions of the programs and found that some programs perform beyond the principles listed in version 1.0. NCQA found that none of the elements of the consensus document should be eliminated because programs cannot perform them, although NCQA suggested some areas where the document could be more expansive or more specific, given the state of MTM operations in the field. The important features and operational elements in the document were categorized into the following 3 overall categories, which NCQA used to structure the survey and conduct the site visits in Phase Two: (1) eligibility and enrollment, (2) operations, and (3) quality management. NCQA found that the original consensus document was realistic in identifying the elements of sound MTM. In the current project, NCQA's purpose was not to make judgments about the effectiveness of MTM programs in general or any individual program in particular. NCQA recommended that the consensus document could be made stronger and more specific in 3 areas: (1) specifically state that the Patient Identification and Recruitment section advocates use of various eligibility criteria that may include, but are not limited to, Medicare-defined MTM eligibility criteria; (2) reframe or remove the statement in Appendix A of the consensus document that the preferred modality for MTM is face-to-face interaction between patient and pharmacist, unless there are comparative data to support it as currently written; and (3) specifically recommend that programs measure performance across the entire populations in their plans in addition to measuring results for those patients selected into MTM. This will make benchmarking among programs possible and will lead to substantiated best practices in this growing field.

  8. Potential Health Implications of Medication Therapy Management Eligibility Criteria in the Patient Protection and Affordable Care Act Across Racial and Ethnic Groups.

    PubMed

    Wang, Junling; Qiao, Yanru; Shih, Ya-Chen Tina; Jarrett-Jamison, JoEllen; Spivey, Christina A; Wan, Jim Y; White-Means, Shelley I; Dagogo-Jack, Samuel; Cushman, William C; Chisholm-Burns, Marie

    2015-11-01

    The Medicare Prescription Drug, Improvement, and Modernization Act requires Part D plans to establish programs to provide medication therapy management (MTM) services starting from 2006. MTM services have been found to improve patient outcomes from pharmacotherapy, reduce emergency room visits and hospitalizations, and reduce health care costs in a cost-effective fashion. However, previous research found that non-Hispanic blacks (blacks) and Hispanics may be less likely to be eligible for MTM services than non-Hispanic whites (whites) among the Medicare population, according to current Medicare MTM eligibility criteria. This finding is because Medicare MTM eligibility criteria are predominantly based on medication use and costs, and blacks and Hispanics tend to use fewer prescription medications and incur lower prescription medication costs. The Patient Protection and Affordable Care Act (PPACA) laid out a set of MTM eligibility criteria for eligible entities to target patients for MTM services: "(1) take 4 or more prescribed medications ...; (2) take any 'high risk' medications; (3) have 2 or more chronic diseases ... or (4) have undergone a transition of care, or other factors ... that are likely to create a high risk of medication-related problems." To (a) examine racial/ethnic disparities in meeting the eligibility criteria for MTM services in PPACA among the Medicare population and (b) determine whether there would be greater disparities in health and economic outcomes among MTM-ineligible than MTM-eligible groups. This was a retrospective cross-sectional analysis of the Medicare Current Beneficiaries Survey (2007-2008). To determine medication characteristics, the U.S. Food and Drug Administration's Electronic Orange Book was also used. Proportions of the population eligible for MTM services based on PPACA MTM eligibility criteria were compared across racial and ethnic groups using a chi-square test; a logistic regression model was used to adjust for population sociodemographic and health characteristics. Health and economic outcomes examined included health status (self-perceived good health status, number of chronic diseases, activities of daily living [ADLs], and instrumental activities of daily living [IADLs]), health services utilization and costs (physician visits, emergency room visits, and total health care costs), and medication use patterns (generic dispensing ratio). To determine difference in disparities across MTM eligibility categories, difference-in-differences regressions of various functional forms were employed, depending on the nature of the dependent variables. Interaction terms between the dummy variables for minority groups (e.g., blacks or Hispanics) and MTM eligibility were included to test whether disparity patterns varied between MTM-ineligible and MTM-eligible individuals. The sample consisted of 12,966 Medicare beneficiaries, of which 11,161 were white, 930 were black, and 875 were Hispanic. Of the study sample, 9,992 whites (86.4%), 825 blacks (86.3%), and 733 Hispanics (80.6%) were eligible for MTM. The difference between whites and Hispanics was significant (P  less than  0.050), and the difference between whites and blacks was not significant (P  greater than 0.050). In multivariate analyses, significant disparity in eligibility for MTM services was found only between Hispanics and whites (odds ratio [OR] = 0.59; 95% CI = 0.43-0.82) but not between blacks and whites (OR = 0.78; 95% CI = 0.55-1.09). Disparities were greater among the MTM-ineligible than the MTM-eligible populations in self-perceived health status, ADLs, and IADLs for both blacks and Hispanics compared with whites. When analyzing the number of chronic conditions, the number and costs of physician visits, and total health care costs, the authors of this study found lower racial and ethnic disparities among the ineligible population than the eligible population. Hispanics are significantly less likely than whites to qualify for MTM among the Medicare population, according to MTM eligibility criteria stipulated in the PPACA. PPACA MTM eligibility criteria may aggravate existing racial and ethnic disparities in health status but may remediate racial and ethnic disparities in health services utilization. Alternative MTM eligibility criteria other than PPACA MTM eligibility criteria may be needed to improve the efficiency and equity of access to Medicare Part D MTM programs.

  9. Design of Ultra-Wideband Tapered Slot Antenna by Using Binomial Transformer with Corrugation

    NASA Astrophysics Data System (ADS)

    Chareonsiri, Yosita; Thaiwirot, Wanwisa; Akkaraekthalin, Prayoot

    2017-05-01

    In this paper, the tapered slot antenna (TSA) with corrugation is proposed for UWB applications. The multi-section binomial transformer is used to design taper profile of the proposed TSA that does not involve using time consuming optimization. A step-by-step procedure for synthesis of the step impedance values related with step slot widths of taper profile is presented. The smooth taper can be achieved by fitting the smoothing curve to the entire step slot. The design of TSA based on this method yields results with a quite flat gain and wide impedance bandwidth covering UWB spectrum from 3.1 GHz to 10.6 GHz. To further improve the radiation characteristics, the corrugation is added on the both edges of the proposed TSA. The effects of different corrugation shapes on the improvement of antenna gain and front-to-back ratio (F-to-B ratio) are investigated. To demonstrate the validity of the design, the prototypes of TSA without and with corrugation are fabricated and measured. The results show good agreement between simulation and measurement.

  10. Polymer taper bridge for silicon waveguide to single mode waveguide coupling

    NASA Astrophysics Data System (ADS)

    Kruse, Kevin; Middlebrook, Christopher T.

    2016-03-01

    Coupling of optical power from high-density silicon waveguides to silica optical fibers for signal routing can incur high losses and often requires complex end-face preparation/processing. Novel coupling device taper structures are proposed for low coupling loss between silicon photonic waveguides and single mode fibers are proposed and devices are fabricated and measured in terms of performance. Theoretical mode conversion models for waveguide tapers are derived for optimal device structure design and performance. Commercially viable vertical and multi-layer taper designs using polymer waveguide materials are proposed as innovative, cost-efficient, and mass-manufacturable optical coupling devices. The coupling efficiency for both designs is determined to evaluate optimal device dimensions and alignment tolerances with both silicon rib waveguides and silicon nanowire waveguides. Propagation loss as a function of waveguide roughness and metallic loss are determined and correlated to waveguide dimensions to obtain total insertion loss for the proposed taper designs. Multi-layer tapers on gold-sputtered substrates are fabricated through photolithography as proof-of-concept devices and evaluated for device loss optimization. Tapered waveguide coupling loss with Si WGs (2.74 dB) was experimentally measured with high correlation to theoretical results.

  11. Pharmacy technician involvement in community pharmacy medication therapy management.

    PubMed

    Lengel, Matthew; Kuhn, Catherine H; Worley, Marcia; Wehr, Allison M; McAuley, James W

    To assess the impact of technician involvement on the completion of medication therapy management (MTM) services in a community pharmacy setting and to describe pharmacists' and technicians' perceptions of technician involvement in MTM-related tasks and their satisfaction with the technician's role in MTM. Prospective observational study. In the fall of 2015, pharmacists and selected technicians from 32 grocery store-based community pharmacies were trained to use technicians within MTM services. Completed MTM claims were evaluated at all pharmacies for 3 months before training and 3 months after training. An electronic survey, developed with the use of competencies taught in the training and relevant published literature, was distributed via e-mail to trained employees 3 months after training. The total number of completed MTM claims at the 32 pharmacy sites was higher during the posttraining time period (2687 claims) versus the pretraining period (1735 claims). Of the 182 trained participants, 112 (61.5%) completed the survey. Overall, perceived technician involvement was lower than expected. However, identifying MTM opportunities was the most commonly reported technician MTM task, with 62.5% of technicians and 47.2% of pharmacists reporting technician involvement. Nearly one-half of technicians (42.5%) and pharmacists (44.0%) agreed or strongly agreed they were satisfied with the technician's role in MTM services, and 40.0% of technicians agreed that they were more satisfied with their work in the pharmacy after involvement in MTM. Three months after initial training of technicians in MTM, participation of technicians was lower than expected. However, the technicians involved most often reported identifying MTM opportunities for pharmacists, which may be a focus for future technician trainings. In addition, technician involvement in MTM services may increase satisfaction with many aspects of work for actively involved technicians. Copyright © 2018 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  12. Positioning and integrating medication therapy management.

    PubMed

    Schommer, Jon C; Doucette, William R; Johnson, Kathleen A; Planas, Lourdes G

    2012-01-01

    To summarize findings from medication therapy management (MTM) "environmental scans" conducted from 2007 through 2010, interpret findings from the environmental scans using insights gained from the Future of MTM Roundtable convened in October 2010, and propose ideas for future positioning and integrating of MTM programs in the U.S. health care system. Data for the environmental scans were collected from purposive samples of MTM pharmacist providers and MTM payers throughout the United States using self-administered online surveys in 2007, 2008, 2009, and 2010. Based on the findings, it appears that MTM is becoming more developed and that some aspects of MTM have become established within the organizations that are providing and paying for these programs. However, the findings also revealed that a need exists to better integrate MTM between organizations and patients serviced (business-to-consumer relationships), between partnering organizations (business-to-business relationships), and between collaborating practitioners (peer-to-peer relationships). The findings suggest that a "channel of distribution" is emerging in which organizational relationships and cost efficiencies will be important considerations in the near term. We propose that applying (1) customer portfolio management and (2) transaction cost economics would help improve positioning and integrating MTM into the U.S. health care system.

  13. Drosophila Mtm and class II PI3K coregulate a PI(3)P pool with cortical and endolysosomal functions.

    PubMed

    Velichkova, Michaella; Juan, Joe; Kadandale, Pavan; Jean, Steve; Ribeiro, Inês; Raman, Vignesh; Stefan, Chris; Kiger, Amy A

    2010-08-09

    Reversible phosphoinositide phosphorylation provides a dynamic membrane code that balances opposing cell functions. However, in vivo regulatory relationships between specific kinases, phosphatases, and phosphoinositide subpools are not clear. We identified myotubularin (mtm), a Drosophila melanogaster MTM1/MTMR2 phosphoinositide phosphatase, as necessary and sufficient for immune cell protrusion formation and recruitment to wounds. Mtm-mediated turnover of endosomal phosphatidylinositol 3-phosphate (PI(3)P) pools generated by both class II and III phosphatidylinositol 3-kinases (Pi3K68D and Vps34, respectively) is needed to down-regulate membrane influx, promote efflux, and maintain endolysosomal homeostasis. Endocytosis, but not endolysosomal size, contributes to cortical remodeling by mtm function. We propose that Mtm-dependent regulation of an endosomal PI(3)P pool has separable consequences for endolysosomal homeostasis and cortical remodeling. Pi3K68D depletion (but not Vps34) rescues protrusion and distribution defects in mtm-deficient immune cells and restores functions in other tissues essential for viability. The broad interactions between mtm and class II Pi3K68D suggest a novel strategy for rebalancing PI(3)P-mediated cell functions in MTM-related human disease.

  14. Mapping the route to medication therapy management documentation and billing standardization and interoperabilility within the health care system: meeting proceedings.

    PubMed

    Millonig, Marsha K

    2009-01-01

    To convene a diverse group of stakeholders to discuss medication therapy management (MTM) documentation and billing standardization and its interoperability within the health care system. More than 70 stakeholders from pharmacy, health information systems, insurers/payers, quality, and standard-setting organizations met on October 7-8, 2008, in Bethesda, MD. The American Pharmacists Association (APhA) organized the invitational conference to facilitate discussion on strategic directions for meeting current market need for MTM documentation and billing interoperability and future market needs for MTM integration into electronic health records (EHRs). APhA recently adopted policy that specifically addresses technology barriers and encourages the use and development of standardized systems for the documentation and billing of MTM services. Day 1 of the conference featured six foundational presentations on health information technology (HIT) trends, perspectives on MTM from the profession and the Centers for Medicare & Medicaid Services, health care quality and medication-related outcome measures, integrating MTM workflow in EHRs, and the current state of MTM operalization in practice. After hearing presentations on day 1 and having the opportunity to pose questions to each speaker, conference participants were divided into three breakout groups on day 2. Each group met three times for 60 minutes each and discussed five questions from the perspective of a patient, provider, or payer. Three facilitators met with each of the groups and led discussion from one perspective (i.e., patient, provider, payer). Participants then reconvened as a complete group to participate in a discussion on next steps. HIT is expected to assist in delivering safe, effective, efficient, coordinated care as health professionals strive to improve the quality of care and outcomes for individual patients. The pharmacy profession is actively contributing to quality patient care through MTM services focused on identifying and preventing medication-related problems, improving medication use, and optimizing individual therapeutic outcomes. As MTM programs continue to expand within the health care system, one important limiting factor is the lack of standardization for documentation and billing of MTM services. This lack of interoperability between technology systems, software, and system platforms is presenting as a barrier to MTM service delivery for patients. APhA convened this invitational conference to identify strategic directions to address MTM documentation and billing standardization and interoperability. Participants viewed the meeting as highly successful in bringing together a unique, wide-ranging set of stakeholders, including the government, regulators, standards organizations, other health professions, technology firms, professional organizations, and practitioners, to share perspectives. They strongly encouraged the Association to continue this unique stakeholder dialogue. Participants provided a number of next-step suggestions for APhA to consider because of the event. Participants noted the pharmacy profession's success in building information technology systems for product transactions with systematic, organized, methodical thinking and the need to apply this success to patient services. A unique opportunity exists for the profession to influence and lead the HIT community in creating a workable health technology solution for MTM services. Reaching consensus on minimum data sets for each functional area--clinical, billing, quality improvement--would be a very important short-term gain. Further, participants said it was imperative for pharmacists and the pharmacy community at large to become actively engaged in HIT standards development efforts.

  15. Navigating complex patients using an innovative tool: the MTM Spider Web.

    PubMed

    Morello, Candis M; Hirsch, Jan D; Lee, Kelly C

    2013-01-01

    To introduce a teaching tool that can be used to assess the complexity of medication therapy management (MTM) patients, prioritize appropriate interventions, and design patient-centered care plans for each encounter. MTM patients are complex as a result of multiple comorbidities, medications, and socioeconomic and behavioral issues. Pharmacists who provide MTM services are required to synthesize a plethora of information (medical and nonmedical), evaluate and prioritize the clinical problems, and design a comprehensive patient-centered care plan. The MTM Spider Web is a visual tool to facilitate this process. A description is provided regarding how to build the MTM Spider Web using case-based scenarios. This model can be used to teach pharmacists, health professional students, and patients. The MTM Spider Web is an innovative teaching tool that can be used to teach pharmacists and students how to assess complex patients and design a patient-centered care plan to deliver the most appropriate medication therapy.

  16. 75 FR 440 - Notice of Proposed Reinstatement of Terminated Oil and Gas Lease MTM 91625

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-05

    ... DEPARTMENT OF THE INTERIOR Bureau of Land Management [LLMT922200-10-L13100000-FI0000-P;MTM 91625] Notice of Proposed Reinstatement of Terminated Oil and Gas Lease MTM 91625 AGENCY: Bureau of Land... for reinstatement of noncompetitive oil and gas lease MTM 91625, Musselshell County, Montana. The...

  17. 75 FR 76753 - Notice of Proposed Reinstatement of Terminated Oil and Gas Lease MTM 91627

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-09

    ... DEPARTMENT OF THE INTERIOR Bureau of Land Management [LLMT922200-11-L13100000-FI0000-P;MTM 91627] Notice of Proposed Reinstatement of Terminated Oil and Gas Lease MTM 91627 AGENCY: Bureau of Land... for reinstatement of noncompetitive oil and gas lease MTM 91627, Musselshell County, Montana. The...

  18. Generating demand for pharmacist-provided medication therapy management: identifying patient-preferred marketing strategies.

    PubMed

    Garcia, Gladys M; Snyder, Margie E; McGrath, Stephanie Harriman; Smith, Randall B; McGivney, Melissa Somma

    2009-01-01

    To identify effective strategies for marketing pharmacist-provided medication therapy management (MTM) services to patients in a self-insured employer setting. Qualitative study. University of Pittsburgh during March through May 2008. 26 university employees taking at least one chronic medication. Three focus group sessions were conducted using a semistructured topic guide to facilitate the discussion. Employees' perceived medication-related needs, perceived benefits of pharmacist-provided MTM, potential barriers for employee participation in MTM, and effective strategies for marketing MTM. Participants reported concerns with timing of doses, medication costs, access, and ensuring adherence. Participants generally felt positively toward pharmacists; however, the level of reported patient contact with pharmacists varied among participants. Some participants questioned pharmacists' education and qualifications for this enhanced role in patient care. Perceived benefits of MTM noted by participants included the opportunity to obtain personalized information about their medications and the potential for improved communication among their health providers. Barriers to patient participation were out-of-pocket costs and lack of time for MTM visits. Participants suggested use of alternative words to describe MTM and marketing approaches that involve personal contact. Pharmacists should emphasize parts of MTM that patients feel are most beneficial (i.e., provision of a personal medication record) and use patient-friendly language to describe MTM when marketing their practice. Patients will need greater exposure to the concept of MTM and the pharmacists' role in order to correctly describe and assign value to this type of pharmacist patient care practice.

  19. Testing multi-theory model (MTM) in predicting initiation and sustenance of physical activity behavior among college students.

    PubMed

    Nahar, Vinayak K; Sharma, Manoj; Catalano, Hannah Priest; Ickes, Melinda J; Johnson, Paul; Ford, M Allison

    2016-01-01

    Most college students do not adequately participate in enough physical activity (PA) to attain health benefits. A theory-based approach is critical in developing effective interventions to promote PA. The purpose of this study was to examine the utility of the newly proposed multi-theory model (MTM) of health behavior change in predicting initiation and sustenance of PA among college students. Using a cross-sectional design, a valid and reliable survey was administered in October 2015 electronically to students enrolled at a large Southern US University. The internal consistency Cronbach alphas of the subscales were acceptable (0.65-0.92). Only those who did not engage in more than 150 minutes of moderate to vigorous intensity aerobic PA during the past week were included in this study. Of the 495 respondents, 190 met the inclusion criteria of which 141 completed the survey. The majority of participants were females (72.3%) and Caucasians (70.9%). Findings of the confirmatory factor analysis (CFA) confirmed construct validity of subscales (initiation model: χ2 = 253.92 [df = 143], P < 0.001, CFI = 0.91, RMSEA = 0.07, SRMR = 0.07; sustenance model: χ2= 19.40 [df = 22], P < 0.001, CFI = 1.00, RMSEA = 0.00, SRMR = 0.03). Multivariate regression analysis showed that 26% of the variance in the PA initiation was explained by advantages outweighing disadvantages, behavioral confidence, work status, and changes in physical environment. Additionally, 29.7% of the variance in PA sustenance was explained by emotional transformation, practice for change, and changes in social environment. Based on this study's findings, MTM appears to be a robust theoretical framework for predicting PA behavior change. Future research directions and development of suitable intervention strategies are discussed.

  20. 76 FR 10389 - Notice of Proposed Reinstatement of Terminated Oil and Gas lease MTM 96122

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-24

    ... DEPARTMENT OF THE INTERIOR Bureau of Land Management [LLMT922200-11-L13100000-FI0000-P;MTM 96122] Notice of Proposed Reinstatement of Terminated Oil and Gas lease MTM 96122 AGENCY: Bureau of Land... filed a petition for reinstatement of competitive oil and gas lease MTM 96122, Richland County, Montana...

  1. 76 FR 54484 - Notice of Proposed Reinstatement of Terminated Oil and Gas Lease MTM 98742

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-01

    ... DEPARTMENT OF THE INTERIOR Bureau of Land Management [LLMT922200-11-L13100000-FI0000-P;MTM 98742] Notice of Proposed Reinstatement of Terminated Oil and Gas Lease MTM 98742 AGENCY: Bureau of Land... petition for reinstatement of competitive oil and gas lease MTM 98742, Fergus County, Montana. The lessee...

  2. 75 FR 63855 - Notice of Proposed Reinstatement of Terminated Oil and Gas Lease MTM 98742, Montana

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-18

    ... DEPARTMENT OF THE INTERIOR Bureau of Land Management [LLMT922200-10-L13100000-FI0000-P;MTM 98742] Notice of Proposed Reinstatement of Terminated Oil and Gas Lease MTM 98742, Montana AGENCY: Bureau of... lease MTM 98742, for land in Fergus County, Montana. The lessee paid the required rental accruing from...

  3. 75 FR 30059 - Notice of Proposed Reinstatement of Terminated Oil and Gas Lease MTM 98343

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-28

    ... DEPARTMENT OF THE INTERIOR Bureau of Land Management [LLMT922200-10-L13100000-FI0000-P; MTM 98343] Notice of Proposed Reinstatement of Terminated Oil and Gas Lease MTM 98343 AGENCY: Bureau of Land... petition for reinstatement of competitive oil and gas lease MTM 98343, Fergus County, Montana. The lessee...

  4. 75 FR 43553 - Notice of Proposed Reinstatement of Terminated Oil and Gas Lease MTM 97827, Montana

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-26

    ... DEPARTMENT OF THE INTERIOR Bureau of Land Management [LLMT922200-10-L13100000-FI0000-P;MTM 97827] Notice of Proposed Reinstatement of Terminated Oil and Gas Lease MTM 97827, Montana AGENCY: Bureau of... and gas lease MTM 97827, Carbon County, Montana. The lessee paid the required rental accruing from the...

  5. Physicians' Preferences for Communication of Pharmacist-Provided Medication Therapy Management in Community Pharmacy.

    PubMed

    Guthrie, Kendall D; Stoner, Steven C; Hartwig, D Matthew; May, Justin R; Nicolaus, Sara E; Schramm, Andrew M; DiDonato, Kristen L

    2017-02-01

    (1) To identify physicians' preferences in regard to pharmacist-provided medication therapy management (MTM) communication in the community pharmacy setting; (2) to identify physicians' perceived barriers to communicating with a pharmacist regarding MTM; and (3) to determine whether Missouri physicians feel MTM is beneficial for their patients. A cross-sectional prospective survey study of 2021 family and general practice physicians registered with MO HealthNet, Missouri's Medicaid program. The majority (52.8%) of physicians preferred MTM data to be communicated via fax. Most physicians who provided care to patients in long-term care (LTC) facilities (81.0%) preferred to be contacted at their practice location as opposed to the LTC facility. The greatest barriers to communication were lack of time and inefficient communication practices. Improved/enhanced communication was the most common suggestion for improvement in the MTM process. Approximately 67% of respondents reported MTM as beneficial or somewhat beneficial for their patients. Survey respondents saw value in the MTM services offered by pharmacists. However, pharmacists should use the identified preferences and barriers to improve their currently utilized communication practices in hopes of increasing acceptance of recommendations. Ultimately, this may assist MTM providers in working collaboratively with patients' physicians.

  6. The identification of solar wind waves at discrete frequencies and the role of the spectral analysis techniques

    NASA Astrophysics Data System (ADS)

    Di Matteo, S.; Villante, U.

    2017-05-01

    The occurrence of waves at discrete frequencies in the solar wind (SW) parameters has been reported in the scientific literature with some controversial results, mostly concerning the existence (and stability) of favored sets of frequencies. On the other hand, the experimental results might be influenced by the analytical methods adopted for the spectral analysis. We focused attention on the fluctuations of the SW dynamic pressure (PSW) occurring in the leading edges of streams following interplanetary shocks and compared the results of the Welch method (WM) with those of the multitaper method (MTM). The results of a simulation analysis demonstrate that the identification of the wave occurrence and the frequency estimate might be strongly influenced by the signal characteristics and analytical methods, especially in the presence of multicomponent signals. In SW streams, PSW oscillations are routinely detected in the entire range f ≈ 1.2-5.0 mHz; nevertheless, the WM/MTM agreement in the identification and frequency estimate occurs in ≈50% of events and different sets of favored frequencies would be proposed for the same set of events by the WM and MTM analysis. The histogram of the frequency distribution of the events identified by both methods suggests more relevant percentages between f ≈ 1.7-1.9, f ≈ 2.7-3.4, and f ≈ 3.9-4.4 (with a most relevant peak at f ≈ 4.2 mHz). Extremely severe thresholds select a small number (14) of remarkable events, with a one-to-one correspondence between WM and MTM: interestingly, these events reveal a tendency for a favored occurrence in bins centered at f ≈ 2.9 and at f ≈ 4.2 mHz.

  7. Assessing Medicare beneficiaries' willingness-to-pay for medication therapy management services.

    PubMed

    Woelfel, Joseph A; Carr-Lopez, Sian M; Delos Santos, Melanie; Bui, Ann; Patel, Rajul A; Walberg, Mark P; Galal, Suzanne M

    2014-02-01

    To assess Medicare beneficiaries' willingness-to-pay (WTP) for medication therapy management (MTM) services and determine sociodemographic and clinical characteristics influencing this payment amount. A cross-sectional, descriptive study design was adopted to elicit Medicare beneficiaries' WTP for MTM. Nine outreach events in cities across Central/Northern California during Medicare's 2011 open-enrollment period. A total of 277 Medicare beneficiaries participated in the study. Comprehensive MTM was offered to each beneficiary. Pharmacy students conducted the MTM session under the supervision of licensed pharmacists. At the end of each MTM session, beneficiaries were asked to indicate their WTP for the service. Medication, self-reported chronic conditions, and beneficiary demographic data were collected and recorded via a survey during the session. The mean WTP for MTM was $33.15 for the 277 beneficiaries receiving the service and answering the WTP question. WTP by low-income subsidy recipients (mean ± standard deviation; $12.80 ± $24.10) was significantly lower than for nonsubsidy recipients ($41.13 ± $88.79). WTP was significantly (positively) correlated with number of medications regularly taken and annual out-of-pocket drug costs. The mean WTP for MTM was $33.15. WTP for MTM significantly varied by race, subsidy status, and number of prescription medications taken. WTP was significantly higher for nonsubsidy recipients than subsidy recipients, and significantly positively correlated with the number of medications regularly taken and the beneficiary rating of the delivered services.

  8. Analysis of pharmacist-provided medication therapy management (MTM) services in community pharmacies over 7 years.

    PubMed

    Barnett, Mitchell J; Frank, Jessica; Wehring, Heidi; Newland, Brand; VonMuenster, Shannon; Kumbera, Patty; Halterman, Tom; Perry, Paul J

    2009-01-01

    Although community pharmacists have historically been paid primarily for drug distribution and dispensing services, medication therapy management (MTM) services evolved in the 1990s as a means for pharmacists and other providers to assist physicians and patients in managing clinical, service, and cost outcomes of drug therapy. The Medicare Prescription Drug, Improvement, and Modernization Act of 2003 (MMA 2003) and the subsequent implementation of Medicare Part D in January 2006 for the more than 20 million Medicare beneficiaries enrolled in the Part D benefit formalized MTM services for a subset of high-cost patients. Although Medicare Part D has provided a new opportunity for defining the value of pharmacist-provided MTM services in the health care system, few publications exist which quantify changes in the provision of pharmacist-provided MTM services over time. To (a) describe the changes over a 7-year period in the primary types of MTM services provided by community pharmacies that have contracted with drug plan sponsors through an MTM administrative services company, and (b) quantify potential MTM-related cost savings based on pharmacists' self-assessments of the likely effects of their interventions on health care utilization. Medication therapy management claims from a multistate MTM administrative services company were analyzed over the 7-year period from January 1, 2000, through December 31, 2006. Data extracted from each MTM claim included patient demographics (e.g., age and gender), the drug and type that triggered the intervention (e.g., drug therapeutic class and therapy type as either acute, intermittent, or chronic), and specific information about the service provided (e.g., Reason, Action, Result, and Estimated Cost Avoidance [ECA]). ECA values are derived from average national health care utilization costs, which are applied to pharmacist self-assessment of the "reasonable and foreseeable" outcome of the intervention. ECA values are updated annually for medical care inflation. From a database of nearly 100,000 MTM claims, a convenience sample of 50 plan sponsors was selected. After exclusion of claims with missing or potentially duplicate data, there were 76,148 claims for 23,798 patients from community pharmacy MTM providers in 47 states. Over the 7-year period from January 1, 2000, through December 31, 2006, the mean ([SD] median) pharmacy reimbursement was $8.44 ([$5.19] $7.00) per MTM service, and the mean ([SD] median) ECA was $93.78 ([$1,022.23] $5.00). During the 7-year period, pharmacist provided MTM interventions changed from primarily education and monitoring for new or changed prescription therapies to prescriber consultations regarding cost-efficacy management (Pearson chi-square P<0.001). Services also shifted from claims involving acute medications (e.g. penicillin antibiotics, macrolide antibiotics, and narcotic analgesics) to services involving chronic medications (e.g., lipid lowering agents, angiotensin-converting enzyme [ACE] inhibitors, and beta-blockers; P<0.001), resulting in significant changes in the therapeutic classes associated with MTM claims and an increase in the proportion of older patients served (P<0.001). These trends resulted in higher pharmacy reimbursements and greater ECA per claim over time (P<0.001). MTM interventions over a 7-year period evolved from primarily the provision of patient education involving acute medications towards consultation-type services for chronic medications. These changes were associated with increases in reimbursement amounts and pharmacist-estimated cost savings. It is uncertain if this shift in service type is a result of clinical need, documentation requirements, or reimbursement opportunities.

  9. Medication Therapy Management in community pharmacy practice: core elements of an MTM service (version 1.0).

    PubMed

    2005-01-01

    To develop a model framework of Medication Therapy Management (MTM) in community pharmacy designed to improve care, enhance communication among patients and providers, improve collaboration among providers, and optimize medication use that leads to improved patient outcomes. Peer-reviewed literature, structured discussions with community pharmacy leaders and representatives from pharmacy benefit providers and health plans, and input from pharmacists and pharmacy associations. Building on an MTM consensus definition adopted by 11 national pharmacy organizations in July 2004, this model describes core elements of an MTM service that can be provided by pharmacists across the spectrum of community pharmacy. The model is structured for pharmacists to use with all patients in need of MTM services, both in the private and public sector. The model describes five core elements of MTM in the community pharmacy setting: medication therapy review (MTR), a personal medication record (PMR), a medication action plan (MAP), intervention and referral, and documentation and follow-up. The MTR can be comprehensive or targeted, depending onthe needs of the patient. The PMR and MAP are patient-centered documents intended to be used by the patient to improve medication self-management. A collaborative approach to patient care involving patients, pharmacists, and physicians and other health care providers is advocated in the model. General patient eligibility considerations are also described. A model framework for consideration by community pharmacists in developing MTM services is described. The model consists of five core elements for MTM service delivery in community pharmacy practice.

  10. Method for fabricating multi-strand superconducting cable

    DOEpatents

    Borden, A.R.

    1985-04-01

    Multi-strand superconducting cables adapted to be used, for example, to wind a magnet are fabricated by directing wire strands inwardly from spools disposed on the perimeter of a rotating disk and wrapping them diagonally around a tapered mandrel with a flattened cross-sectional shape with a core having a wedge-shaped channel. As the cable is pulled axially, flexibly coupled wedge-shaped pieces are continuously passed through the channel in the mandrel and inserted into the cable as an internal support therefor.

  11. Apparatus and method for fabricating multi-strand superconducting cable

    DOEpatents

    Borden, Albert R.

    1986-01-01

    Multi-strand superconducting cables adapted to be used, for example, to wind a magnet is fabricated by directing wire strands inwardly from spools disposed on the perimeter of a rotating disk and wrapping them diagonally around a tapered mandrel with a flattened cross-sectional shape with a core having a wedge-shaped channel. As the cable is pulled axially, flexibly coupled wedge-shaped pieces are continuously passed through the channel in the mandrel and inserted into the cable as an internal support therefor.

  12. Comparison of two Medication Therapy Management Practice Models on Return on Investment.

    PubMed

    Gazda, Nicholas P; Berenbrok, Lucas A; Ferreri, Stefanie P

    2017-06-01

    To compare the return on investment (ROI) of an integrated practice model versus a "hub and spoke" practice model of pharmacist provided medication therapy management (MTM). A cohort retrospective analysis of MTM claims billed in 76 pharmacies in North Carolina in the 2010 hub and spoke practice model and the 2012 "integrated" practice model were analyzed to calculate the ROI. In 2010, 4089 patients received an MTM resulting in 8757 claims in the hub and spoke model. In 2012, 4896 patients received an MTM resulting in 13 730 claims in the integrated model. In 2010, US$165 897.26 was invested in pharmacist salary and $173 498.00 was received in reimbursement, resulting in an ROI of +US$7600.74 (+4.6%). In 2012, US$280 890.09 was invested in pharmacist salary and US$302 963 was received in reimbursement, resulting in an ROI of +US$22 072.91 or (+7.9%). The integrated model of MTM showed an increase in number of claims submitted and in number of patients receiving MTM services, ultimately resulting in a higher ROI. While a higher ROI was evident in the integrated model, both models resulted in positive ROI (1:12-1:21), highlighting that MTM programs can be cost effective with different strategies of execution.

  13. Impact of medication therapy management on underserved, primarily Hispanic patients with diabetes.

    PubMed

    Congdon, Heather B; Dowling, Thomas C; Cheng, Iliana; Truong, Hoai-An

    2013-05-01

    Diabetes-related complications are more pronounced in Hispanic patients versus patients of other ethnicities. It is documented that medication therapy management (MTM) can improve diabetes outcomes; however, data regarding Hispanic patients are limited. To evaluate the impact of MTM on hemoglobin A1c (A1C), blood pressure (BP), and low-density lipoprotein cholesterol (LDL-C) in underserved, primarily Hispanic patients who use a safety-net clinic as their medical home. A retrospective, observational study of uninsured, primarily Hispanic patients with diabetes who received MTM from October 2009 through March 2011. Patients were stratified into 2 cohorts: A1C less than 9% and A1C greater than or equal to 9%. Patients were also stratified by frequency of MTM visits and insulin use, regardless of A1C. A chart review was conducted to evaluate diabetes-related outcomes pre- and postimplementation of MTM. The primary study outcome was reduction of A1C. Secondary outcomes included reduction of BP and LDL-C and reduction of A1C based on MTM visit frequency or insulin use. Sixty-four patients with at least 1 MTM visit and pre- and postimplementation A1C data were included. In the cohort with A1C greater than or equal to 9%, mean (SD) A1C values decreased from 10.9% (1.4%) to 8.8% (1.5%) versus the cohort with A1C less than 9%, whose A1C changed minimally, from 7.2% (0.9%) to 7.4% (1.4%). Regardless of their A1C, patients who were using insulin at baseline had a change in A1C of -0.8% (1.5%) versus -0.1% (1.6%) in those who were not using insulin at baseline (p = 0.04); patients who participated in multiple MTM visits had a significant reduction in A1C, from 9% to 8.3% (95% CI -1.26 to -0.03; p = 0.02) compared with patients participating in only 1 MTM visit. Pharmacist-provided MTM can significantly improve diabetes control in uninsured, primarily Hispanic patients with poorly controlled diabetes and in those who are using insulin. Multiple MTM visits also yielded significant A1C reductions.

  14. Economic cycles and their synchronization: Spectral analysis of macroeconomic series from Italy, The Netherlands, and the UK

    NASA Astrophysics Data System (ADS)

    Sella, Lisa; Vivaldo, Gianna; Ghil, Michael; Groth, Andreas

    2010-05-01

    The present work applies several advanced spectral methods (Ghil et al., Rev. Geophys., 2002) to the analysis of macroeconomic fluctuations in Italy, The Netherlands, and the United Kingdom. These methods provide valuable time-and-frequency-domain tools that complement traditional time-domain analysis, and are thus fairly well known by now in the geosciences and life sciences, but not yet widespread in quantitative economics. In particular, they enable the identification and characterization of nonlinear trends and dominant cycles --- including low-frequency and seasonal components --- that characterize the behavior of each time series. We explore five fundamental indicators of the real (i.e., non-monetary), aggregate economy --- namely gross domestic product (GDP), consumption, fixed investments, exports and imports --- in a univariate as well as multivariate setting. A single-channel analysis by means of three independent spectral methods --- singular spectrum analysis (SSA), the multi-taper method (MTM), and the maximum-entropy method (MEM) --- reveals very similar near-annual cycles, as well as several longer periodicities, in the macroeconomic indicators of all the countries analyzed. Since each indicator represents different features of an economic system, we combine them to infer if common oscillatory modes are present, either among different indicators within the same country or among the same indicators across different countries. Multichannel-SSA (M-SSA) reinforces the previous results, and shows that the common modes agree in character with solutions of a non-equilibrium dynamic model (NEDyM) that produces endogenous business cycles (Hallegatte et al., JEBO, 2008). The presence of these modes in NEDyM results from adjustment delays and other nonequilibrium effects that were added to a neoclassical Solow (Q. J. Econ., 1956) growth model. Their confirmation by the present analysis has important consequences for the net impact of natural disasters on the economy of a country: Hallegatte and Ghil (Ecol. Econ., 2008) have shown that the presence of business cycles modifies substantially this impact with respect to their impact on an economy in or near equilibrium. The present work concludes with a study of the synchronization of economic fluctuations, which follows a similar study of macroeconomic indicators for the United States, presented in a nearby poster. Since business cycles are not country-specific phenomena, but show common characteristics across countries, our aim is to uncover hidden global behavior across the European economies (cf. Mazzi and Savio, Macmillan, 2006).

  15. Racial and ethnic disparities in meeting MTM eligibility criteria among patients with asthma.

    PubMed

    Lu, Degan; Qiao, Yanru; Johnson, Karen C; Wang, Junling

    2017-06-01

    Asthma is one of the most frequently targeted chronic diseases in the medication therapy management (MTM) programs of the Medicare prescription drug (Part D) benefits. Although racial and ethnic disparities in meeting eligibility criteria for MTM services have been reported, little is known about whether there would be similar disparities among adults with asthma in the United States. Adult patients with asthma (age ≥ 18) from Medical Expenditure Panel Survey (2011-2012) were analyzed. Bivariate analyses were conducted to compare the proportions of patients who would meet Medicare MTM eligibility criteria between non-Hispanic Blacks (Blacks), Hispanics and non-Hispanic Whites (Whites). Survey-weighted logistic regression was performed to adjust for patient characteristics. Main and sensitivity analyses were conducted to cover the entire range of the eligibility thresholds used by Part D plans in 2011-2012. The sample included 4,455 patients with asthma, including 2,294 Whites, 1,218 Blacks, and 943 Hispanics. Blacks and Hispanics had lower proportions of meeting MTM eligibility criteria than did Whites (P < 0.001). According to the main analysis, Blacks and Hispanics had 36% and 32% lower, respectively, likelihood of MTM eligibility than Whites (odds ratio [OR]: 0.64, 95% confidence interval [CI]: 0.45-0.90; OR: 0.68, 95% CI: 0.47-0.98, respectively). Similar results were obtained in sensitivity analyses. There are racial and ethnic disparities in meeting Medicare Part D MTM eligibility criteria among adult patients with asthma. Future studies should examine the implications of such disparities on health outcomes of patients with asthma and explore alternative MTM eligibility criteria.

  16. An introductory pharmacy practice experience based on a medication therapy management service model.

    PubMed

    Agness, Chanel F; Huynh, Donna; Brandt, Nicole

    2011-06-10

    To implement and evaluate an introductory pharmacy practice experience (IPPE) based on the medication therapy management (MTM) service model. Patient Care 2 is an IPPE that introduces third-year pharmacy students to the MTM service model. Students interacted with older adults to identify medication-related problems and develop recommendations using core MTM elements. Course outcome evaluations were based on number of documented medication-related problems, recommendations, and student reviews. Fifty-seven older adults participated in the course. Students identified 52 medication-related problems and 66 medical problems, and documented 233 recommendations relating to health maintenance and wellness, pharmacotherapy, referrals, and education. Students reported having adequate experience performing core MTM elements. Patient Care 2 may serve as an experiential learning model for pharmacy schools to teach the core elements of MTM and provide patient care services to the community.

  17. Multiplex and simultaneous measurement of displacement and temperature using tapered fiber and fiber Bragg grating.

    PubMed

    Ji, Chongke; Zhao, Chun-Liu; Kang, Juan; Dong, Xinyong; Jin, Shangzhong

    2012-05-01

    A simple method to work out the multiplexing of tapered fiber based sensors is proposed and demonstrated. By cascading a tapered fiber with a fiber Bragg grating (FBG), the sensor head is provided with a wavelength identification, different FBGs provide the sensor heads with different reflective peaks and they can be distinguished in optical spectrum. By compositing several such sensor heads with a multi-channel beam splitter, a star-style topological structure sensor for multipoint sensing is achieved. At the same time, the output intensity at the peak wavelength is sensitive to one external physical parameter applied on the related FBG-cascaded tapered fiber and the central wavelength of the peak is only sensitive to temperature, so that that parameter and temperature can be measured simultaneously. A sensor for dual-point measurement of the displacement and temperature simultaneously is experimentally demonstrated by using a 2 × 2 coupler in this paper. Experiment results show that the sensor works well and the largest sensitivities reach to 0.11 dB/μm for displacement in the range of 0-400 μm, and ∼0.0097 nm/°C for temperature between 20 °C and 70 °C.

  18. Effect of Eruption Status of the Mandibular Third Molar on Distal Caries in the Adjacent Second Molar.

    PubMed

    Kang, Feiwu; Huang, Cheng; Sah, Manoj Kumar; Jiang, Beizhan

    2016-04-01

    To analyze the effect of the eruption status of the mandibular third molar (MTM) on distal caries in the mandibular second molar (MSM) by cone-beam computed tomography (CBCT). Five hundred CBCT images of MTMs from 469 patients were evaluated. Presence of distal caries in MSMs, impaction depths and angulations of MTMs, cementoenamel junction (CEJ) distances between distal MSMs and mesial MTMs, presence of pericoronitis in MTMs, and patient characteristics (age and gender) were assessed. Data were analyzed by χ(2) test, univariate and multivariate logistic regression analyses, and Spearman correlation analysis. Descriptive and bivariate statistics were computed and the P value was set at .05. The overall prevalence of distal caries in the MSM was 52.0%. According to the classification of Pell and Gregory, position A was the impaction depth at which most distal caries in MSMs were present (P = .036). For angulation of the MTM, when mesial angulations were 43° to 73°, MSMs developed more distal caries (P < .0001). For the CEJ distance between the distal MSM and the mesial MTM, when distances ranged from 6 to 15 mm, distal caries in MSMs occurred more frequently (6 to 8 mm, P < .0001; 8 to 15 mm, P = .037). Furthermore, there was a linear correlation between angulation of the MTM and the CEJ distance between the distal MSM and the mesial MTM (P < .0001). Impaction depth and angulation of the MTM are associated with distal caries in the MSM. Angulation of the MTM is more stable and reliable than the CEJ distance between the distal MSM and the mesial MTM for the estimation of risk factors related to the MTM. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  19. A tapered multi-gap multi-aperture pseudospark-sourced electron gun based X-band slow wave oscillator

    NASA Astrophysics Data System (ADS)

    Kumar, N.; Lamba, R. P.; Hossain, A. M.; Pal, U. N.; Phelps, A. D. R.; Prakash, R.

    2017-11-01

    The experimental study of a tapered, multi-gap, multi-aperture pseudospark-sourced electron gun based X-band plasma assisted slow wave oscillator is presented. The designed electron gun is based on the pseudospark discharge concept and has been used to generate a high current density and high energy electron beam simultaneously. The distribution of apertures has been arranged such that the field penetration potency inside the backspace of the hollow-cathode is different while passing through the tapered gap region. This leads to non-concurrent ignition of the discharge through all the channels which is, in general, quite challenging in the case of multi-aperture plasma cathode electron gun geometries. Multiple and successive hollow cathode phases are reported from this electron gun geometry, which have been confirmed using simulations. This geometry also has led to the achievement of ˜71% fill factor inside the slow wave oscillator for an electron beam of energy of 20 keV and a beam current density in the range of 115-190 A/cm2 at a working argon gas pressure of 18 Pa. The oscillator has generated broadband microwave output in the frequency range of 10-11.7 GHz with a peak power of ˜10 kW for ˜50 ns.

  20. Review of survey articles regarding medication therapy management (MTM) services/programs in the United States.

    PubMed

    Oladapo, Abiola O; Rascati, Karen L

    2012-08-01

    To provide a summary of published survey articles regarding the provision of medication therapy management (MTM) services in the United States. A literature search was conducted to identify original articles on MTM-related surveys conducted in the United States, involving community and outpatient pharmacists, physicians, patients, or pharmacy students and published by the primary researchers who conducted the study. Search engines used included PubMed, Medline, and International Pharmaceutical Abstracts (IPA). If MTM was in the keyword list, mesh heading, title, or abstract, the article was reviewed. References from these articles were searched to determine whether other relevant articles were available. A total of 405 articles were initially reviewed; however, only 32 articles met the study requirements. Of the 32 articles, 17 surveyed community/outpatient pharmacists, 3 surveyed pharmacy students, 4 surveyed physicians, and 8 surveyed patients. The survey periods varied across the different studies, with the earliest survey conducted in 2004 and the most recent survey conducted in 2009. The surveys were conducted via the telephone, US mail, interoffice mail, e-mails, Internet/Web sites, hand-delivered questionnaires, and focus groups. Despite the identified barriers to the provision of MTM services, pharmacists reportedly found it professionally rewarding to provide these services. Pharmacists claimed to have adequate clinical knowledge, experience, and access to information required to provide MTM services. Pharmacy students were of the opinion that the provision of MTM services was important to the advancement of the pharmacy profession and in providing patients with a higher level of care. Physicians supported having pharmacists adjust patients’ drug therapy and educate patients on general drug information but not in selecting patients’ drug therapy. Finally, patients suggested that alternative ways need to be explored in describing and marketing MTM services for it to be appealing to them.

  1. "How do I say that?": Using communication principles to enhance medication therapy management instruction.

    PubMed

    Denvir, Paul M; Cardone, Katie E; Parker, Wendy M; Cerulli, Jennifer

    2018-02-01

    Medication therapy management (MTM) is a comprehensive, patient-centered approach to improving medication use, reducing the risk of adverse events and improving medication adherence. Given the service delivery model and required outputs of MTM services, communication skills are of utmost importance. The objectives of this study were to identify and describe communication principles and instructional practices to enhance MTM training. Drawing on formative assessment data from interviews of both pharmacy educators and alumni, this article identifies and describes communication principles and instructional practices that pharmacy educators can use to enhance MTM training initiatives to develop student communication strategies. Analysis revealed five key communication challenges of MTM service delivery, two communication principles that pharmacy teachers and learners can use to address those challenges, and a range of specific strategies, derived from communication principles, that students can use when challenges emerge. Implications of the analysis for pharmacy educators and researchers are described. Proactive communication training provided during MTM advanced pharmacy practice experiences enabled students to apply the principles and instructional strategies to specific patient interactions during the advanced pharmacy practice experiences and in their post-graduation practice settings. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Joint High-Order Synchrosqueezing Transform and Multi-Taper Empirical Wavelet Transform for Fault Diagnosis of Wind Turbine Planetary Gearbox under Nonstationary Conditions.

    PubMed

    Hu, Yue; Tu, Xiaotong; Li, Fucai; Meng, Guang

    2018-01-07

    Wind turbines usually operate under nonstationary conditions, such as wide-range speed fluctuation and time-varying load. Its critical component, the planetary gearbox, is prone to malfunction or failure, which leads to downtime and repair costs. Therefore, fault diagnosis and condition monitoring for the planetary gearbox in wind turbines is a vital research topic. Meanwhile, the signals measured by the vibration sensors mounted in the gearbox exhibit time-varying and nonstationary features. In this study, a novel time-frequency method based on high-order synchrosqueezing transform (SST) and multi-taper empirical wavelet transform (MTEWT) is proposed for the wind turbine planetary gearbox under nonstationary conditions. The high-order SST uses accurate instantaneous frequency approximations to obtain a sharper time-frequency representation (TFR). As the acquired signal consists of many components, like the meshing and rotating components of the gear and bearing, the fault component may be masked by other unrelated components. The MTEWT is used to separate the fault feature from the masking components. A variety of experimental signals of the wind turbine planetary gearbox under nonstationary conditions have been analyzed to demonstrate the effectiveness and robustness of the proposed method. Results show that the proposed method is effective in diagnosing both gear and bearing faults.

  3. Joint High-Order Synchrosqueezing Transform and Multi-Taper Empirical Wavelet Transform for Fault Diagnosis of Wind Turbine Planetary Gearbox under Nonstationary Conditions

    PubMed Central

    Li, Fucai; Meng, Guang

    2018-01-01

    Wind turbines usually operate under nonstationary conditions, such as wide-range speed fluctuation and time-varying load. Its critical component, the planetary gearbox, is prone to malfunction or failure, which leads to downtime and repair costs. Therefore, fault diagnosis and condition monitoring for the planetary gearbox in wind turbines is a vital research topic. Meanwhile, the signals measured by the vibration sensors mounted in the gearbox exhibit time-varying and nonstationary features. In this study, a novel time-frequency method based on high-order synchrosqueezing transform (SST) and multi-taper empirical wavelet transform (MTEWT) is proposed for the wind turbine planetary gearbox under nonstationary conditions. The high-order SST uses accurate instantaneous frequency approximations to obtain a sharper time-frequency representation (TFR). As the acquired signal consists of many components, like the meshing and rotating components of the gear and bearing, the fault component may be masked by other unrelated components. The MTEWT is used to separate the fault feature from the masking components. A variety of experimental signals of the wind turbine planetary gearbox under nonstationary conditions have been analyzed to demonstrate the effectiveness and robustness of the proposed method. Results show that the proposed method is effective in diagnosing both gear and bearing faults. PMID:29316668

  4. Isotopic imprints of mountaintop mining contaminants.

    PubMed

    Vengosh, Avner; Lindberg, T Ty; Merola, Brittany R; Ruhl, Laura; Warner, Nathaniel R; White, Alissa; Dwyer, Gary S; Di Giulio, Richard T

    2013-09-03

    Mountaintop mining (MTM) is the primary procedure for surface coal exploration within the central Appalachian region of the eastern United States, and it is known to contaminate streams in local watersheds. In this study, we measured the chemical and isotopic compositions of water samples from MTM-impacted tributaries and streams in the Mud River watershed in West Virginia. We systematically document the isotopic compositions of three major constituents: sulfur isotopes in sulfate (δ(34)SSO4), carbon isotopes in dissolved inorganic carbon (δ(13)CDIC), and strontium isotopes ((87)Sr/(86)Sr). The data show that δ(34)SSO4, δ(13)CDIC, Sr/Ca, and (87)Sr/(86)Sr measured in saline- and selenium-rich MTM impacted tributaries are distinguishable from those of the surface water upstream of mining impacts. These tracers can therefore be used to delineate and quantify the impact of MTM in watersheds. High Sr/Ca and low (87)Sr/(86)Sr characterize tributaries that originated from active MTM areas, while tributaries from reclaimed MTM areas had low Sr/Ca and high (87)Sr/(86)Sr. Leaching experiments of rocks from the watershed show that pyrite oxidation and carbonate dissolution control the solute chemistry with distinct (87)Sr/(86)Sr ratios characterizing different rock sources. We propose that MTM operations that access the deeper Kanawha Formation generate residual mined rocks in valley fills from which effluents with distinctive (87)Sr/(86)Sr and Sr/Ca imprints affect the quality of the Appalachian watersheds.

  5. Buprenorphine tapering schedule and illicit opioid use

    PubMed Central

    Ling, Walter; Hillhouse, Maureen; Domier, Catherine; Doraimani, Geetha; Hunter, Jeremy; Thomas, Christie; Jenkins, Jessica; Hasson, Albert; Annon, Jeffrey; Saxon, Andrew; Selzer, Jeffrey; Boverman, Joshua; Bilangi, Richard

    2011-01-01

    Aims To compare the effects of a short or long taper schedule after buprenorphine stabilization on participant outcomes as measured by opioid-free urine tests at the end of each taper period. Design This multi-site study sponsored by Clinical Trials Network (CTN, a branch of the US National Institute on Drug Abuse) was conducted from 2003 to 2005 to compare two taper conditions (7 days and 28 days). Data were collected at weekly clinic visits to the end of the taper periods, and at 1-month and 3-month post-taper follow-up visits. Setting Eleven out-patient treatment programs in 10 US cities. Intervention Non-blinded dosing with Suboxone® during the 1-month stabilization phase included 3 weeks of flexible dosing as determined appropriate by the study physicians. A fixed dose was required for the final week before beginning the taper phase. Measurements The percentage of participants in each taper group providing urine samples free of illicit opioids at the end of the taper and at follow-up. Findings At the end of the taper, 44% of the 7-day taper group (n = 255) provided opioid-free urine specimens compared to 30% of the 28-day taper group (n = 261; P = 0.0007). There were no differences at the 1-month and 3-month follow-ups (7-day = 18% and 12%; 28-day = 18% and 13%, 1 month and 3 months, respectively). Conclusion For individuals terminating buprenorphine pharmacotherapy for opioid dependence, there appears to be no advantage in prolonging the duration of taper. PMID:19149822

  6. Switchable multi-wavelength erbium-doped fiber ring laser based on a tapered in-line Mach–Zehnder interferometer

    NASA Astrophysics Data System (ADS)

    Zhou, Yuxin; Wang, Xin; Tang, Zijuan; Lou, Shuqin

    2018-05-01

    In this paper, a switchable multi-wavelength erbium-doped fiber ring laser based on a tapered in-line Mach–Zehnder interferometer is proposed. The in-line Mach–Zehnder interferometer is fabricated by splicing a large-core fiber between two segments of single mode fibers, in which the first splicing point is tapered and the second splicing point is connected directly. By carefully rotating the polarization controller, switchable single-, dual-, triple- and quad-wavelength lasing outputs can be obtained with a side mode suppression ratio higher than 50 dB. The maximal peak power difference of multi-wavelength lasing is 3.67 dB, demonstrating a good power equalization performance. Furthermore, the proposed laser is proven to be very stable at room temperature. The wavelength shifts and peak power fluctuations are less than 0.02 nm and 1.3 dB over half an hour. In addition, stable quintuple-wavelength lasing with a side mode suppression ratio higher than 50 dB can also be realized when the filter length is changed.

  7. Multi-dimensional optimization of a terawatt seeded tapered Free Electron Laser with a Multi-Objective Genetic Algorithm

    DOE PAGES

    Wu, Juhao; Hu, Newman; Setiawan, Hananiel; ...

    2016-11-20

    There is a great interest in generating high-power hard X-ray Free Electron Laser (FEL) in the terawatt (TW) level that can enable coherent diffraction imaging of complex molecules like proteins and probe fundamental high-field physics. A feasibility study of producing such X-ray pulses was carried out in this paper employing a configuration beginning with a Self-Amplified Spontaneous Emission FEL, followed by a “self-seeding” crystal monochromator generating a fully coherent seed, and finishing with a long tapered undulator where the coherent seed recombines with the electron bunch and is amplified to high power. The undulator tapering profile, the phase advance inmore » the undulator break sections, the quadrupole focusing strength, etc. are parameters to be optimized. A Genetic Algorithm (GA) is adopted for this multi-dimensional optimization. Concrete examples are given for LINAC Coherent Light Source (LCLS) and LCLS-II-type systems. Finally, analytical estimate is also developed to cross check the simulation and optimization results as a quick and complimentary tool.« less

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bosserman, Mary A.; Downey, Theresa; Noinaj, Nicholas

    Baeyer–Villiger monooxygenases (BVMOs) have been shown to play key roles for the biosynthesis of important natural products. MtmOIV, a homodimeric FAD- and NADPH-dependent BVMO, catalyzes the key frame-modifying steps of the mithramycin biosynthetic pathway, including an oxidative C–C bond cleavage, by converting its natural substrate premithramycin B into mithramycin DK, the immediate precursor of mithramycin. The drastically improved protein structure of MtmOIV along with the high-resolution structure of MtmOIV in complex with its natural substrate premithramycin B are reported here, revealing previously undetected key residues that are important for substrate recognition and catalysis. Kinetic analyses of selected mutants allowed usmore » to probe the substrate binding pocket of MtmOIV and also to discover the putative NADPH binding site. This is the first substrate-bound structure of MtmOIV providing new insights into substrate recognition and catalysis, which paves the way for the future design of a tailored enzyme for the chemo-enzymatic preparation of novel mithramycin analogues.« less

  9. Pilot study: incorporation of pharmacogenetic testing in medication therapy management services.

    PubMed

    Haga, Susanne B; Allen LaPointe, Nancy M; Moaddeb, Jivan; Mills, Rachel; Patel, Mahesh; Kraus, William E

    2014-11-01

    Aim: To describe the rationale and design of a pilot study evaluating the integration of pharmacogenetic (PGx) testing into pharmacist-delivered medication therapy management (MTM). Study rationale: Clinical delivery approaches of PGx testing involving pharmacists may overcome barriers of limited physician knowledge about and experience with testing. Study design: We will assess the addition of PGx testing to MTM services for cardiology patients taking three or more medications including simvastatin or clopidogrel. We will measure the impact of MTM plus PGx testing on drug/dose adjustment and clinical outcomes. Factors associated with delivery, such as time to prepare and conduct MTM and consult with physicians will be recorded. Additionally, patient interest and satisfaction will be measured. Anticipated results: We anticipate that PGx testing can be practically integrated into standard a MTM service, providing a viable delivery model for testing. Conclusion: Given the lack of evidence of an effective PGx delivery models, this study will provide preliminary evidence regarding a pharmacist-delivered approach.

  10. 76 FR 18778 - Notice of Proposed Reinstatement of Terminated Oil and Gas Leases MTM 89460, MTM 89461, MTM 89467...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-05

    ... that affect these lands. The lessee agrees to new lease terms for rentals and royalties of $10 per acre and 16\\2/3\\ percent. The lessee paid the $500 administration fee for the reinstatement of each lease... leases; The increased rental of $10 per acre; The increased royalty of 16\\2/3\\ percent; and The $163 cost...

  11. Medication therapy management: its relationship to patient counseling, disease management, and pharmaceutical care.

    PubMed

    McGivney, Melissa Somma; Meyer, Susan M; Duncan-Hewitt, Wendy; Hall, Deanne L; Goode, Jean-Venable R; Smith, Randall B

    2007-01-01

    To delineate the relationship, including similarities and differences, between medication therapy management (MTM) and contemporary pharmacist-provided services, including patient counseling, disease management, and pharmaceutical care, to facilitate the continued evolution of commonly used language and a standard of practice across geographic areas and practice environments. Incorporation of MTM services into the array of Medicare-funded services affords an opportunity for pharmacists to develop direct patient care services in the community. Defining the role of MTM within the scope of pharmacist-provided patient care activities, including patient counseling, disease management, and all currently provided pharmacy services is essential to the delineation of a viable and sustainable practice model for pharmacists. The definitions of each of these services are offered, as well as comparisons and contrasts of the individual services. In addition to Medicare-eligible patients, MTM services are appropriate for anyone with medication-related needs. MTM is offered as an all-encompassing model that incorporates the philosophy of pharmaceutical care, techniques of patient counseling, and disease management in an environment that facilitates the direct collaboration of patients, pharmacists, and other health professionals. Defining the role of MTM within the current patient care models, including patient counseling, disease management, and all who provide pharmacy services, is essential in delineating a viable and sustainable practice model for pharmacists.

  12. A natural history study of X-linked myotubular myopathy.

    PubMed

    Amburgey, Kimberly; Tsuchiya, Etsuko; de Chastonay, Sabine; Glueck, Michael; Alverez, Rachel; Nguyen, Cam-Tu; Rutkowski, Anne; Hornyak, Joseph; Beggs, Alan H; Dowling, James J

    2017-09-26

    To define the natural history of X-linked myotubular myopathy (MTM). We performed a cross-sectional study that included an online survey (n = 35) and a prospective, 1-year longitudinal investigation using a phone survey (n = 33). We ascertained data from 50 male patients with MTM and performed longitudinal assessments on 33 affected individuals. Consistent with existing knowledge, we found that MTM is a disorder associated with extensive morbidities, including wheelchair (86.7% nonambulant) and ventilator (75% requiring >16 hours of support) dependence. However, unlike previous reports and despite the high burden of disease, mortality was lower than anticipated (approximate rate 10%/y). Seventy-six percent of patients with MTM enrolled (mean age 10 years 11 months) were alive at the end of the study. Nearly all deaths in the study were associated with respiratory failure. In addition, the disease course was more stable than expected, with few adverse events reported during the prospective survey. Few non-muscle-related morbidities were identified, although an unexpectedly high incidence of learning disability (43%) was noted. Conversely, MTM was associated with substantial burdens on patient and caregiver daily living, reflected by missed days of school and lost workdays. MTM is one of the most severe neuromuscular disorders, with affected individuals requiring extensive mechanical interventions for survival. However, among study participants, the disease course was more stable than predicted, with more individuals surviving infancy and early childhood. These data reflect the disease burden of MTM but offer hope in terms of future therapeutic intervention. Copyright © 2017 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the American Academy of Neurology.

  13. Cortical integrity of the inferior alveolar canal as a predictor of paresthesia after third-molar extraction.

    PubMed

    Park, Wonse; Choi, Ji-Wook; Kim, Jae-Young; Kim, Bong-Chul; Kim, Hyung Jun; Lee, Sang-Hwy

    2010-03-01

    Paresthesia is a well-known complication of extraction of mandibular third molars (MTMs). The authors evaluated the relationship between paresthesia after MTM extraction and the cortical integrity of the inferior alveolar canal (IAC) by using computed tomography (CT). The authors designed a retrospective cohort study involving participants considered, on the basis of panoramic imaging, to be at high risk of experiencing injury of the inferior alveolar nerve who subsequently underwent CT imaging and extraction of the MTMs. The primary predictor variable was the contact relationship between the IAC and the MTM as viewed on a CT image, classified into three groups: group 1, no contact; group 2, contact between the MTM and the intact IAC cortex; group 3, contact between the MTM and the interrupted IAC cortex. The secondary predictor variable was the number of CT image slices showing the cortical interruption around the MTM. The outcome variable was the presence or absence of postoperative paresthesia after MTM extraction. The study sample comprised 179 participants who underwent MTM extraction (a total of 259 MTMs). Their mean age was 23.6 years, and 85 (47.5 percent) were male. The overall prevalence of paresthesia was 4.2 percent (11 of 259 teeth). The prevalence of paresthesia in group 3 (involving an interrupted IAC cortex) was 11.8 percent (10 of 85 cases), while for group 2 (involving an intact IAC cortex) and group 1 (involving no contact) it was 1.0 percent (1 of 98 cases) and 0.0 percent (no cases), respectively. The frequency of nerve damage increased with the number of CT image slices showing loss of cortical integrity (P=.043). The results of this study indicate that loss of IAC cortical integrity is associated with an increased risk of experiencing paresthesia after MTM extraction.

  14. Freeze-drying process design by manometric temperature measurement: design of a smart freeze-dryer.

    PubMed

    Tang, Xiaolin Charlie; Nail, Steven L; Pikal, Michael J

    2005-04-01

    To develop a procedure based on manometric temperature measurement (MTM) and an expert system for good practices in freeze drying that will allow development of an optimized freeze-drying process during a single laboratory freeze-drying experiment. Freeze drying was performed with a FTS Dura-Stop/Dura-Top freeze dryer with the manometric temperature measurement software installed. Five percent solutions of glycine, sucrose, or mannitol with 2 ml to 4 ml fill in 5 ml vials were used, with all vials loaded on one shelf. Details of freezing, optimization of chamber pressure, target product temperature, and some aspects of secondary drying are determined by the expert system algorithms. MTM measurements were used to select the optimum shelf temperature, to determine drying end points, and to evaluate residual moisture content in real-time. MTM measurements were made at 1 hour or half-hour intervals during primary drying and secondary drying, with a data collection frequency of 4 points per second. The improved MTM equations were fit to pressure-time data generated by the MTM procedure using Microcal Origin software to obtain product temperature and dry layer resistance. Using heat and mass transfer theory, the MTM results were used to evaluate mass and heat transfer rates and to estimate the shelf temperature required to maintain the target product temperature. MTM product dry layer resistance is accurate until about two-thirds of total primary drying time is over, and the MTM product temperature is normally accurate almost to the end of primary drying provided that effective thermal shielding is used in the freeze-drying process. The primary drying times can be accurately estimated from mass transfer rates calculated very early in the run, and we find the target product temperature can be achieved and maintained with only a few adjustments of shelf temperature. The freeze-dryer overload conditions can be estimated by calculation of heat/mass flow at the target product temperature. It was found that the MTM results serve as an excellent indicator of the end point of primary drying. Further, we find that the rate of water desorption during secondary drying may be accurately measured by a variation of the basic MTM procedure. Thus, both the end point of secondary drying and real-time residual moisture may be obtained during secondary drying. Manometric temperature measurement and the expert system for good practices in freeze drying does allow development of an optimized freeze-drying process during a single laboratory freeze-drying experiment.

  15. Application of process analytical technology for monitoring freeze-drying of an amorphous protein formulation: use of complementary tools for real-time product temperature measurements and endpoint detection.

    PubMed

    Schneid, Stefan C; Johnson, Robert E; Lewis, Lavinia M; Stärtzel, Peter; Gieseler, Henning

    2015-05-01

    Process analytical technology (PAT) and quality by design have gained importance in all areas of pharmaceutical development and manufacturing. One important method for monitoring of critical product attributes and process optimization in laboratory scale freeze-drying is manometric temperature measurement (MTM). A drawback of this innovative technology is that problems are encountered when processing high-concentrated amorphous materials, particularly protein formulations. In this study, a model solution of bovine serum albumin and sucrose was lyophilized at both conservative and aggressive primary drying conditions. Different temperature sensors were employed to monitor product temperatures. The residual moisture content at primary drying endpoints as indicated by temperature sensors and batch PAT methods was quantified from extracted sample vials. The data from temperature probes were then used to recalculate critical product parameters, and the results were compared with MTM data. The drying endpoints indicated by the temperature sensors were not suitable for endpoint indication, in contrast to the batch methods endpoints. The accuracy of MTM Pice data was found to be influenced by water reabsorption. Recalculation of Rp and Pice values based on data from temperature sensors and weighed vials was possible. Overall, extensive information about critical product parameters could be obtained using data from complementary PAT tools. © 2015 Wiley Periodicals, Inc. and the American Pharmacists Association.

  16. Suitability of Secondary PEEK Telescopic Crowns on Zirconia Primary Crowns: The Influence of Fabrication Method and Taper.

    PubMed

    Merk, Susanne; Wagner, Christina; Stock, Veronika; Eichberger, Marlis; Schmidlin, Patrick R; Roos, Malgorzata; Stawarczyk, Bogna

    2016-11-08

    This study investigates the retention load (RL) between ZrO₂ primary crowns and secondary polyetheretherketone (PEEK) crowns made by different fabrication methods with three different tapers. Standardized primary ZrO₂ crowns were fabricated with three different tapers: 0°, 1°, and 2° ( n = 10/group). Ten secondary crowns were fabricated (i) milled from breCam BioHPP blanks (PM); (ii) pressed from industrially fabricated PEEK pellets (PP) (BioHPP Pellet); or (iii) pressed from granular PEEK (PG) (BioHPP Granulat). One calibrated operator adjusted all crowns. In total, the RL of 90 secondary crowns were measured in pull-off tests at 50 mm/min, and each specimen was tested 20 times. Two- and one-way ANOVAs followed by a Scheffé's post-hoc test were used for data analysis ( p < 0.05). Within crowns with a 0° taper, the PP group showed significantly higher retention load values compared with the other groups. Among the 1° taper, the PM group presented significantly lower retention loads than the PP group. However, the pressing type had no impact on the results. Within the 2° taper, the fabrication method had no influence on the RL. Within the PM group, the 2° taper showed significantly higher retention load compared with the 1° taper. The taper with 0° was in the same range value as the 1° and 2° tapers. No impact of the taper on the retention value was observed between the PP groups. Within the PG groups, the 0° taper presented significantly lower RL than the 1° taper, whereas the 2° taper showed no differences. The fabrication method of the secondary PEEK crowns and taper angles showed no consistent effect within all tested groups.

  17. Getting It Right Matters: Climate Spectra and Their Estimation

    NASA Astrophysics Data System (ADS)

    Privalsky, Victor; Yushkov, Vladislav

    2018-06-01

    In many recent publications, climate spectra estimated with different methods from observed, GCM-simulated, and reconstructed time series contain many peaks at time scales from a few years to many decades and even centuries. However, respective spectral estimates obtained with the autoregressive (AR) and multitapering (MTM) methods showed that spectra of climate time series are smooth and contain no evidence of periodic or quasi-periodic behavior. Four order selection criteria for the autoregressive models were studied and proven sufficiently reliable for 25 time series of climate observations at individual locations or spatially averaged at local-to-global scales. As time series of climate observations are short, an alternative reliable nonparametric approach is Thomson's MTM. These results agree with both the earlier climate spectral analyses and the Markovian stochastic model of climate.

  18. Differential Muscle Hypertrophy Is Associated with Satellite Cell Numbers and Akt Pathway Activation Following Activin Type IIB Receptor Inhibition in Mtm1 p.R69C Mice

    PubMed Central

    Lawlor, Michael W.; Viola, Marissa G.; Meng, Hui; Edelstein, Rachel V.; Liu, Fujun; Yan, Ke; Luna, Elizabeth J.; Lerch-Gaggl, Alexandra; Hoffmann, Raymond G.; Pierson, Christopher R.; Buj-Bello, Anna; Lachey, Jennifer L.; Pearsall, Scott; Yang, Lin; Hillard, Cecilia J.; Beggs, Alan H.

    2015-01-01

    X-linked myotubular myopathy is a congenital myopathy caused by deficiency of myotubularin. Patients often present with severe perinatal weakness, requiring mechanical ventilation to prevent death from respiratory failure. We recently reported that an activin receptor type IIB inhibitor produced hypertrophy of type 2b myofibers and modest increases of strength and life span in the severely myopathic Mtm1δ4 mouse model of X-linked myotubular myopathy. We have now performed a similar study in the less severely symptomatic Mtm1 p.R69C mouse in hopes of finding greater treatment efficacy. Activin receptor type IIB inhibitor treatment of Mtm1 p.R69C animals produced behavioral and histological evidence of hypertrophy in gastrocnemius muscles but not in quadriceps or triceps. The ability of the muscles to respond to activin receptor type IIB inhibitor treatment correlated with treatment-induced increases in satellite cell number and several muscle-specific abnormalities of hypertrophic signaling. Treatment-responsive Mtm1 p.R69C gastrocnemius muscles displayed lower levels of phosphorylated ribosomal protein S6 and higher levels of phosphorylated eukaryotic elongation factor 2 kinase than were observed in Mtm1 p.R69C quadriceps muscle or in muscles from wild-type littermates. Hypertrophy in the Mtm1 p.R69C gastrocnemius muscle was associated with increased levels of phosphorylated ribosomal protein S6. Our findings indicate that muscle-, fiber type-, and mutation-specific factors affect the response to hypertrophic therapies that will be important to assess in future therapeutic trials. PMID:24726641

  19. The BepiColombo Spacecraft: The Mercury Transfer Module Structure Qualification Test Campaign Description

    NASA Astrophysics Data System (ADS)

    Martin Zurdo, M. J.

    2012-07-01

    The BepiColombo is a space mission to Mercury (ESA in cooperation with Japan Aerospace Exploration Agency). The spacecraft consist of three different structures: two orbiters responsible for the scientific mission (MPO and MMO) and one service module, Mercury Transfer Module (MTM), which provides propulsion and services during the journey to Mercury. Taking into account only the MTM structure, the companies involved are ASTRIUM GERMANY acting as the prime contractor and ASTRIUM UK acting as the co- prime contractor company. EADS CASA Espacio (ECE) in Spain is the company responsible for the final design, manufacturing and qualification of the MTM structure. The test campaign specimen is the MTM core structure, which corresponds to the central cone with the structure floors, shear panels and tank support structure. This test campaign qualifies the primary load path and its primary interfaces; the rest of the MTM structure is qualified by system level vibration test. In order to qualify the MTM structure, three different kinds of qualification tests have been performed: stiffness test, global strength test and local tests in different specific areas. The most relevant test during the campaign is the global strength test case, in which several external loads are introduced (different interfaces) simulating the load introduction for a selected critical flight case. There are two important items in the qualification test campaign: 1. The instrumentation of the structure, with two main functions: to control the specimen under test loads, and to demonstrate the qualification of the structure. 2. The set-up structure, designed by ECE to allow the correct load introduction on each testing case during the whole test campaign. This paper describes the MTM structure test campaign from the definition of the loads applied in each test to the qualification of the complete structure.

  20. Myotubular Myopathy in a girl with a deletion of Xq27-q28 and unbalanced X inactivation assigns the MTM1 gene to a 600-kb region

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dahl, N.; Mandel, J.L.; Chery, M.

    1995-05-01

    A young girl with a clinically moderate form of myotubular myopathy was found to carry a cytogenetically detectable deletion in Xq27-q28. The deletion had occurred de novo on the paternal X chromosome. It encompasses the fragile X (FRAXA) and Hunter syndrome (IDS) loci, and the DXS304 and DXS455 markers, in Xq27.3 and proximal Xq28. Other loci from the proximal half of Xq28 (DXS49, DXS256, DXS258, DXS305, and DXS497) were found intact. As the X-linked myotubular myopathy locus (MTM1) was previously mapped to Xq28 by linkage analysis, the present observation suggested that MTM1 is included in the deletion. However, a significantmore » clinical phenotype is unexpected in a female MTM1 carrier. Analysis of inactive X-specific methylation at the androgen receptor gene showed that the deleted X chromosome was active in {approximately}80% of leukocytes. Such unbalanced inactivation may account for the moderate MTM1 phenotype and for the mental retardation that later developed in the patient. This observation is discussed in relation to the hypothesis that a locus modulating X inactivation may lie in the region. Comparison of this deletion with that carried by a male patient with a severe Hunter syndrome phenotype but no myotubular myopathy, in light of recent linkage data on recombinant MTM1 families, led to a considerable refinement of the position of the MTM1 locus, to a region of {approximately}600 kb, between DXS304 and DXS497. 46 refs., 4 figs.« less

  1. Differential muscle hypertrophy is associated with satellite cell numbers and Akt pathway activation following activin type IIB receptor inhibition in Mtm1 p.R69C mice.

    PubMed

    Lawlor, Michael W; Viola, Marissa G; Meng, Hui; Edelstein, Rachel V; Liu, Fujun; Yan, Ke; Luna, Elizabeth J; Lerch-Gaggl, Alexandra; Hoffmann, Raymond G; Pierson, Christopher R; Buj-Bello, Anna; Lachey, Jennifer L; Pearsall, Scott; Yang, Lin; Hillard, Cecilia J; Beggs, Alan H

    2014-06-01

    X-linked myotubular myopathy is a congenital myopathy caused by deficiency of myotubularin. Patients often present with severe perinatal weakness, requiring mechanical ventilation to prevent death from respiratory failure. We recently reported that an activin receptor type IIB inhibitor produced hypertrophy of type 2b myofibers and modest increases of strength and life span in the severely myopathic Mtm1δ4 mouse model of X-linked myotubular myopathy. We have now performed a similar study in the less severely symptomatic Mtm1 p.R69C mouse in hopes of finding greater treatment efficacy. Activin receptor type IIB inhibitor treatment of Mtm1 p.R69C animals produced behavioral and histological evidence of hypertrophy in gastrocnemius muscles but not in quadriceps or triceps. The ability of the muscles to respond to activin receptor type IIB inhibitor treatment correlated with treatment-induced increases in satellite cell number and several muscle-specific abnormalities of hypertrophic signaling. Treatment-responsive Mtm1 p.R69C gastrocnemius muscles displayed lower levels of phosphorylated ribosomal protein S6 and higher levels of phosphorylated eukaryotic elongation factor 2 kinase than were observed in Mtm1 p.R69C quadriceps muscle or in muscles from wild-type littermates. Hypertrophy in the Mtm1 p.R69C gastrocnemius muscle was associated with increased levels of phosphorylated ribosomal protein S6. Our findings indicate that muscle-, fiber type-, and mutation-specific factors affect the response to hypertrophic therapies that will be important to assess in future therapeutic trials. Copyright © 2014 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.

  2. Community pharmacy-based medication therapy management services: financial impact for patients.

    PubMed

    Dodson, Sarah E; Ruisinger, Janelle F; Howard, Patricia A; Hare, Sarah E; Barnes, Brian J

    2012-07-01

    To determine the direct financial impact for patients resulting from Medication Therapy Management (MTM) interventions made by community pharmacists. Secondary objectives include evaluating the patient and physician acceptance rates of the community pharmacists' recommended MTM interventions. This was a retrospective observational study conducted at 20 Price Chopper and Hen House grocery store chain pharmacies in the Kansas City metro area from January 1, 2010 to December 31, 2010. Study patients were Medicare Part D beneficiaries eligible for MTM services. The primary outcome was the change in patient out-of-pocket prescription medication expense as a result of MTM services. Of 128 patients included in this study, 68% experienced no out-of-pocket financial impact on their medication expenses as a result of MTM services. A total of 27% of the patients realized a cost-savings (USD440.50 per year, (SD=289.69)) while another 5% of patients saw a cost increase in out-of-pocket expense (USD255.66 per year, (SD=324.48)). The net financial impact for all 128 patients who participated in MTM services was an average savings of USD102.83 per patient per year (SD=269.18, p<0.0001). Pharmacists attempted a total of 732 recommendations; 391 (53%) were accepted by both the patient and their prescriber. A total of 341 (47%) recommendations were not accepted because of patient refusal (290, 85%) or prescriber refusal (51, 15%). Patient participation in MTM services reduces patient out-of-pocket medication expense. However, this savings is driven by only 32% of subjects who are experiencing a financial impact on out-of-pocket medication expense. Additionally, the majority of the pharmacists' recommended interventions (53%) were accepted by patients and prescribers.

  3. Retrospective financial analysis of medication therapy management services from the pharmacy's perspective.

    PubMed

    McDonough, Randal P; Harthan, Aaron A; McLeese, Kelly E; Doucette, William R

    2010-01-01

    To determine the net financial gain or loss for medication therapy management (MTM) services provided to patients by an independent community pharmacy during 16 months of operation. Retrospective study. Independent community pharmacy in Iowa City, IA, from September 1, 2006, to December 31, 2007. Patients receiving MTM services during the specified period who had proper documentation of reimbursement for the services. MTM services were provided to the patient and documented by the pharmacist or student pharmacist. Net financial gains or losses for providing MTM services. Sensitivity analyses included costs that might be incurred under various conditions of operation. 103 initial and 88 follow-up MTM visits were conducted during a 16-month time period. The total cost for these services to the pharmacy was $11,191.72. Total revenue from these services was $11,195.00; therefore, the pharmacy experienced a net financial gain of $3.28. Sensitivity analyses were conducted, revealing the net gain/loss to the pharmacy if a student pharmacist was used and the net gain/loss if the pharmacist needed extra training to provide the services. Using a student pharmacist resulted in a net gain of $6,308.48, while extra training for the pharmacist resulted in a net loss of $1,602.72. The MTM service programs showed a positive financial gain after 16 months of operation, which should encourage pharmacists to incorporate these services into their practice.

  4. Acute effects of single and multiple level thoracic manipulations on chronic mechanical neck pain: a randomized controlled trial

    PubMed Central

    Puntumetakul, Rungthip; Suvarnnato, Thavatchai; Werasirirat, Phurichaya; Uthaikhup, Sureeporn; Yamauchi, Junichiro; Boucaut, Rose

    2015-01-01

    Background Thoracic spine manipulation has become a popular alternative to local cervical manipulative therapy for mechanical neck pain. This study investigated the acute effects of single-level and multiple-level thoracic manipulations on chronic mechanical neck pain (CMNP). Methods Forty-eight patients with CMNP were randomly allocated to single-level thoracic manipulation (STM) at T6–T7 or multiple-level thoracic manipulation (MTM), or to a control group (prone lying). Cervical range of motion (CROM), visual analog scale (VAS), and the Thai version of the Neck Disability Index (NDI-TH) scores were measured at baseline, and at 24-hour and at 1-week follow-up. Results At 24-hour and 1-week follow-up, neck disability and pain levels were significantly (P<0.05) improved in the STM and MTM groups compared with the control group. CROM in flexion and left lateral flexion were increased significantly (P<0.05) in the STM group when compared with the control group at 1-week follow-up. The CROM in right rotation was increased significantly after MTM compared to the control group (P<0.05) at 24-hour follow-up. There were no statistically significant differences in neck disability, pain level at rest, and CROM between the STM and MTM groups. Conclusion These results suggest that both single-level and multiple-level thoracic manipulation improve neck disability, pain levels, and CROM at 24-hour and 1-week follow-up in patients with CMNP. PMID:25624764

  5. Movement-to-music computer technology: a developmental play experience for children with severe physical disabilities.

    PubMed

    Tam, Cynthia; Schwellnus, Heidi; Eaton, Ceilidh; Hamdani, Yani; Lamont, Andrea; Chau, Tom

    2007-01-01

    Children with severe physical disabilities often lack the physical skills to explore their environment independently, and to play with toys or musical instruments. The movement-to-music (MTM) system is an affordable computer system that allows children with limited movements to play and create music. The present study explored parents' experiences of using the MTM system with their children. A qualitative methodology employing in-depth interview techniques was used with six mothers and their children. The themes extracted from the data were organized under two main concepts of the International Classification of Functioning, Disability, and Health (ICF) (WHO, 2001) framework. The results showed that the MTM expanded horizons for the child along the ICF health dimensions and the MTM had a positive impact on ICF environmental determinants of health. The small sample size should be noted as a limitation of this study. Further research should be carried out with a larger sample of children with restricted mobility to obtain a better understanding of the impact of MTM technology on children's psychosocial development.

  6. Traditional lecture versus jigsaw learning method for teaching Medication Therapy Management (MTM) core elements.

    PubMed

    Wilson, Jennifer A; Pegram, Angela H; Battise, Dawn M; Robinson, April M

    2017-11-01

    To determine if traditional didactic lecture or the jigsaw learning method is more effective to teach the medication therapy management (MTM) core elements in a first year pharmacy course. Traditional didactic lecture and a pre-class reading assignment were used in the fall semester cohort, and the jigsaw method was used in the spring semester cohort. Jigsaw is a cooperative learning strategy requiring students to assume responsibility for learning, and subsequently teaching peers. The students were responsible for reading specific sections of the pre-class reading, and then teaching other students in small groups about their specific reading assignments. To assess potential differences, identical pre- and post-tests were administered before and after the MTM section. Additionally, grade performance on an in-class project and final exam questions were compared, and students were surveyed on perceptions of teaching method used. A total of 45 and 43 students completed both the pre- and post-test in the fall and spring (96% and 93% response rate), respectively. Improvement in post-test scores favored the traditional method (p = 0.001). No statistical differences were noted between groups with grade performance on the in-class project and final exam questions. However, students favored the jigsaw method over traditional lecture and perceived improvements in problem solving skills, listening/communication skills and encouragement of cooperative learning (p = 0.018, 0.025 and 0.031). Although students favored the jigsaw learning method, traditional didactic lecture was more effective for the pre- and post-knowledge test performance. This may indicate that traditional didactic lecture is more effective for more foundational content. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Using pharmacists to improve risk stratification and management of stage 3A chronic kidney disease: a feasibility study.

    PubMed

    Chang, Alex R; Evans, Michael; Yule, Christina; Bohn, Larissa; Young, Amanda; Lewis, Meredith; Graboski, Elisabeth; Gerdy, Bethany; Ehmann, William; Brady, Jonathan; Lawrence, Leah; Antunes, Natacha; Green, Jamie; Snyder, Susan; Kirchner, H Lester; Grams, Morgan; Perkins, Robert

    2016-11-08

    Measurement of albuminuria to stratify risk in chronic kidney disease (CKD) is not done universally in the primary care setting despite recommendation in KDIGO (Kidney Disease Improving Global Outcomes) guidelines. Pharmacist medication therapy management (MTM) may be helpful in improving CKD risk stratification and management. We conducted a pragmatic, cluster-randomized trial using seven primary care clinic sites in the Geisinger Health System to evaluate the feasibility of pharmacist MTM in patients with estimated glomerular filtration rate (eGFR) 45-59 ml/min/1.73 m 2 and uncontrolled blood pressure (≥150/85 mmHg). In the three pharmacist MTM sites, pharmacists were instructed to follow a protocol aimed to improve adherence to KDIGO guidelines on testing for proteinuria and lipids, and statin and blood pressure medical therapy. In the four control clinics, patients received usual care. The primary outcome was proteinuria screening over a follow-up of 1 year. A telephone survey was administered to physicians, pharmacists, and patients in the pharmacist MTM arm at the end of the trial. Baseline characteristics were similar between pharmacist MTM (n = 24) and control (n = 23) patients, although pharmacist MTM patients tended to be younger (64 vs. 71 y; p = 0.06) and less likely to have diabetes (17 % vs. 35 %; p = 0.2) or baseline proteinuria screening (41.7 % vs. 60.9 %, p = 0.2). Mean eGFR was 54 ml/min/1.73 m 2 in both groups. The pharmacist MTM intervention did not significantly improve total proteinuria screening at the population level (OR 2.6, 95 % CI: 0.5-14.0; p = 0.3). However, it tended to increase screening of previously unscreened patients (78.6 % in the pharmacist MTM group compared to 33.3 % in the control group; OR 7.3, 95 % CI: 0.96-56.3; p = 0.05). In general, the intervention was well-received by patients, pharmacists, and providers, who agreed that pharmacists could play an important role in CKD management. A few patients contacted the research team to express anxiety about having a CKD diagnosis without prior knowledge. Pharmacist MTM may be useful in improving risk stratification and management of CKD in the primary care setting, although implementation requires ongoing education and multidisciplinary collaboration and careful communication regarding CKD diagnosis. Future studies are needed to establish the effectiveness of pharmacist MTM on slowing CKD progression and improvement in cardiovascular outcomes. ClinicalTrials.gov, NCT02208674 Registered August 1, 2014, first patient enrolled September 30, 2014.

  8. Effect of an Advanced Pharmacy Practice Experience on Medication Therapy Management Services in a Centralized Retail Pharmacy Program.

    PubMed

    Vande Griend, Joseph P; Rodgers, Melissa; Nuffer, Wesley

    2017-05-01

    Medication therapy management (MTM) delivery is increasingly important in managed care. Successful delivery positively affects patient health and improves Centers for Medicare & Medicaid Services star ratings, a measure of health plan quality. As MTM services continue to grow, there is an increased need for efficient and effective care models. The primary objectives of this project were to describe the delivery of MTM services by fourth-year Advanced Pharmacy Practice Experience (APPE) students in a centralized retail pharmacy system and to evaluate and quantify the clinical and financial contributions of the students. The secondary objective was to describe the engagement needed to complete comprehensive medication reviews (CMRs) and targeted interventions. From May 2015 to December 2015, thirty-five APPE students from the University of Colorado Skaggs School of Pharmacy provided MTM services at Albertsons Companies using the OutcomesMTM and Mirixa platforms. Students delivered patient care services by phone at the central office and provided face-to-face visits at pharmacies in the region. With implementation of the MTM APPE in 2015, the team consisted of 2 MTM pharmacists and pharmacy students, as compared with 1 MTM pharmacist in 2014. The number of CMRs and targeted interventions completed and the estimated additional revenue generated during the 2015 time period were compared with those completed from May through December 2014. The patient and provider engagement needed to complete the CMRs and targeted interventions was summarized. 125 CMRs and 1,918 targeted interventions were billed in 2015, compared with 13 CMRs and 767 targeted interventions in 2014. An estimated $16,575-$49,272 of additional revenue was generated in 2015. To complete the interventions in 2015, the team engaged in 1,714 CMR opportunities and 4,686 targeted intervention opportunities. In this MTM rotation, students provided real-life care to patients, resulting in financial and clinical contributions. This model of education and care delivery can be replicated in the community pharmacy or managed care setting. APPE students are an important component of this model of care delivery, particularly when considering the level of patient engagement needed to complete MTM interventions. No outside funding supported this research. The authors have no conflicts of interest to disclose related to this work. All authors contributed to study concept and design. Rodgers collected the data, and data interpretation was performed by Vande Griend, along with Rodgers and Nuffer. The manuscript was written and revised primarily by Vande Griend, along with Nuffer and Rodgers. This project was presented at the Pharmacy Quality Alliance Annual Meeting in Arlington, Virginia, in May 2016.

  9. Serum protein measurement using a tapered fluorescent fibre-optic evanescent wave-based biosensor

    NASA Astrophysics Data System (ADS)

    Preejith, P. V.; Lim, C. S.; Chia, T. F.

    2006-12-01

    A novel method to measure the total serum protein concentration is described in this paper. The method is based on the principles of fibre-optic evanescent wave spectroscopy. The biosensor applies a fluorescent dye-immobilized porous glass coating on a multi-mode optical fibre. The evanescent wave's intensity at the fibre-optic core-cladding interface is used to monitor the protein-induced changes in the sensor element. The sensor offers a rapid, single-step method for quantifying protein concentrations without destroying the sample. This unique sensing method presents a sensitive and accurate platform for the quantification of protein.

  10. Minnesota Department of Human Services audit of medication therapy management programs.

    PubMed

    Smith, Stephanie; Cell, Penny; Anderson, Lowell; Larson, Tom

    2013-01-01

    To inform medication therapy management (MTM) providers of findings of the Minnesota Department of Human Services review of claims submitted to Minnesota Health Care Programs (MHCP) for patients receiving MTM services and to discuss the impact of the audit on widespread MTM services and future audits. A retrospective review was completed on MTM claims submitted to MHCP from 2008 to 2010. The auditor verified that the Current Procedural Terminology codes billed matched the actual number of medications, conditions, and drug therapy problems assessed during an encounter. 190 claims were reviewed for 57 distinct pharmacies that billed for MTM services from 2008 to 2010, representing 4.5% of all claims submitted. The auditor reported that generally, the documentation within the electronic medical record had the least "up-coding" of all documentation systems. A total of 18 claims were coded at a higher level than appropriate, but only 10 notices were sent out to recover money because the others did not meet the minimum $50 threshold. The auditor expressed concerns that a number of claims billed at the highest complexity level were only 15 minutes long. Providers will need to be cautious of the conditions that they bill as complex and of how they define drug therapy problems. Everything for which is being billed must be clearly assessed or rationalized in the documentation note. The auditor expressed that overall, documentation was well done; however, many MTM providers are now asking how to internally prepare for future audits.

  11. Variation of nanopore diameter along porous anodic alumina channels by multi-step anodization.

    PubMed

    Lee, Kwang Hong; Lim, Xin Yuan; Wai, Kah Wing; Romanato, Filippo; Wong, Chee Cheong

    2011-02-01

    In order to form tapered nanocapillaries, we investigated a method to vary the nanopore diameter along the porous anodic alumina (PAA) channels using multi-step anodization. By anodizing the aluminum in either single acid (H3PO4) or multi-acid (H2SO4, oxalic acid and H3PO4) with increasing or decreasing voltage, the diameter of the nanopore along the PAA channel can be varied systematically corresponding to the applied voltages. The pore size along the channel can be enlarged or shrunken in the range of 20 nm to 200 nm. Structural engineering of the template along the film growth direction can be achieved by deliberately designing a suitable voltage and electrolyte together with anodization time.

  12. Atmospheric particulate matter in proximity to mountaintop coal mines: Sources and potential environmental and human health impacts

    USGS Publications Warehouse

    Kurth, Laura; Kolker, Allan; Engle, Mark A.; Geboy, Nicholas J.; Hendryx, Michael; Orem, William H.; McCawley, Michael; Crosby, Lynn M.; Tatu, Calin A.; Varonka, Matthew S.; DeVera, Christina A.

    2015-01-01

    Mountaintop removal mining (MTM) is a widely used approach to surface coal mining in the US Appalachian region whereby large volumes of coal overburden are excavated using explosives, removed, and transferred to nearby drainages below MTM operations. To investigate the air quality impact of MTM, the geochemical characteristics of atmospheric particulate matter (PM) from five surface mining sites in south central West Virginia, USA, and five in-state study control sites having only underground coal mining or no coal mining whatsoever were determined and compared. Epidemiologic studies show increased rates of cancer, respiratory disease, cardiovascular disease, and overall mortality in Appalachian surface mining areas compared to Appalachian non-mining areas. In the present study, 24-h coarse (>2.5 µm) and fine (≤2.5 µm) PM samples were collected from two surface mining sites in June 2011 showed pronounced enrichment in elements having a crustal affinity (Ga, Al, Ge, Rb, La, Ce) contributed by local sources, relative to controls. Follow-up sampling in August 2011 lacked this enrichment, suggesting that PM input from local sources is intermittent. Using passive samplers, dry deposition total PM elemental fluxes calculated for three surface mining sites over multi-day intervals between May and August 2012 were 5.8 ± 1.5 times higher for crustal elements than at controls. Scanning microscopy of 2,249 particles showed that primary aluminosilicate PM was prevalent at surface mining sites compared to secondary PM at controls. Additional testing is needed to establish any link between input of lithogenic PM and disease rates in the study area.

  13. Atmospheric particulate matter in proximity to mountaintop coal mines: sources and potential environmental and human health impacts.

    PubMed

    Kurth, Laura; Kolker, Allan; Engle, Mark; Geboy, Nicholas; Hendryx, Michael; Orem, William; McCawley, Michael; Crosby, Lynn; Tatu, Calin; Varonka, Matthew; DeVera, Christina

    2015-06-01

    Mountaintop removal mining (MTM) is a widely used approach to surface coal mining in the US Appalachian region whereby large volumes of coal overburden are excavated using explosives, removed, and transferred to nearby drainages below MTM operations. To investigate the air quality impact of MTM, the geochemical characteristics of atmospheric particulate matter (PM) from five surface mining sites in south central West Virginia, USA, and five in-state study control sites having only underground coal mining or no coal mining whatsoever were determined and compared. Epidemiologic studies show increased rates of cancer, respiratory disease, cardiovascular disease, and overall mortality in Appalachian surface mining areas compared to Appalachian non-mining areas. In the present study, 24-h coarse (>2.5 µm) and fine (≤2.5 µm) PM samples were collected from two surface mining sites in June 2011 showed pronounced enrichment in elements having a crustal affinity (Ga, Al, Ge, Rb, La, Ce) contributed by local sources, relative to controls. Follow-up sampling in August 2011 lacked this enrichment, suggesting that PM input from local sources is intermittent. Using passive samplers, dry deposition total PM elemental fluxes calculated for three surface mining sites over multi-day intervals between May and August 2012 were 5.8 ± 1.5 times higher for crustal elements than at controls. Scanning microscopy of 2,249 particles showed that primary aluminosilicate PM was prevalent at surface mining sites compared to secondary PM at controls. Additional testing is needed to establish any link between input of lithogenic PM and disease rates in the study area.

  14. Nacre-mimetic clay/xyloglucan bionanocomposites: a chemical modification route for hygromechanical performance at high humidity.

    PubMed

    Kochumalayil, Joby J; Morimune, Seira; Nishino, Takashi; Ikkala, Olli; Walther, Andreas; Berglund, Lars A

    2013-11-11

    Nacre-mimetic bionanocomposites of high montmorillonite (MTM) clay content, prepared from hydrocolloidal suspensions, suffer from reduced strength and stiffness at high relative humidity. We address this problem by chemical modification of xyloglucan in (XG)/MTM nacre-mimetic nanocomposites, by subjecting the XG to regioselective periodate oxidation of side chains to enable it to form covalent cross-links to hydroxyl groups in neighboring XG chains or to the MTM surface. The resulting materials are analyzed by FTIR spectroscopy, thermogravimetric analysis, carbohydrate analysis, calorimetry, X-ray diffraction, scanning electron microscopy, tensile tests, and oxygen barrier properties. We compare the resulting mechanical properties at low and high relative humidity. The periodate oxidation leads to a strong increase in modulus and strength of the materials. A modulus of 30 GPa for cross-linked composite at 50% relative humidity compared with 13.7 GPa for neat XG/MTM demonstrates that periodate oxidation of the XG side chains leads to crucially improved stress transfer at the XG/MTM interface, possibly through covalent bond formation. This enhanced interfacial adhesion and internal cross-linking of the matrix moreover preserves the mechanical properties at high humidity condition and leads to a Young's modulus of 21 GPa at 90%RH.

  15. School of pharmacy-based medication therapy management program: development and initial experience.

    PubMed

    Lam, Annie; Odegard, Peggy Soule; Gardner, Jacqueline

    2012-01-01

    To describe a school of pharmacy-community pharmacy collaborative model for medication therapy management (MTM) service and training. University of Washington (UW) School of Pharmacy (Seattle), from July to December 2008. MTM services and training. A campus-based MTM pharmacy was established for teaching, practice, and collaboration with community pharmacies to provide comprehensive medication reviews (CMRs) and MTM training. Number of collaborating pharmacies, number of patients contacted, number of CMRs conducted, and estimated cost avoidance (ECA). UW Pharmacy Cares was licensed as a Class A pharmacy (nondispensing) and signed "business associate" agreements with six community pharmacies. During July to December 2008, 10 faculty pharmacists completed training and 5 provided CMR services to 17 patients (5 telephonic and 12 face-to-face interviews). A total of 67 claims (17 CMRs and 50 CMR-generated claims) were submitted for reimbursement of $1,642 ($96.58/CMR case). Total ECA was $54,250, averaging $3,191.19 per patient. Seven student pharmacists gained CMR interview training. Interest in collaboration by community pharmacies was lower than expected; however, the campus-community practice model addressed unmet patient care needs, reduced outstanding MTM CMR case loads, increased ECA, and facilitated faculty development and training of student pharmacists.

  16. HIV medication therapy management services in community pharmacies

    PubMed Central

    Kauffman, Yardlee; Nair, Vidya; Herist, Keith; Thomas, Vasavi; Weidle, Paul J.

    2015-01-01

    Objectives To present a rationale and a proposed structure to support pharmacist-delivered medication therapy management (MTM) for human immunodeficiency virus (HIV) disease and to outline challenges to implementing and sustaining the service. Data sources Professional literature. Summary Historically, the effect of pharmacy services for HIV-infected persons has been demonstrated in inpatient and clinic-based settings. Developing similar programs adapted for community pharmacists could be a model of care to improve patient adherence to antiretroviral therapy and retention in care. Initiation of antiretroviral therapy and regular monitoring of CD4+ cell count, HIV RNA viral load, adverse drug events, and adherence form the backbone of successful medical management of HIV infection. Support for these services can be provided to HIV-infected patients through pharmacist-managed HIV MTM programs in community pharmacy settings in collaboration with primary providers and other health care professionals. Conclusion Community pharmacists can help meet the growing need for HIV care through provision of MTM services. Although resources have been developed, including the general MTM framework, challenges of adequate training, education, and support of community pharmacists need to be addressed in order for HIV MTM to be a successful model. PMID:23229993

  17. Integrating home-based medication therapy management (MTM) services in a health system.

    PubMed

    Reidt, Shannon; Holtan, Haley; Stender, Jennifer; Salvatore, Toni; Thompson, Bruce

    2016-01-01

    To describe the integration of home-based Medication Therapy Management (MTM) into the ambulatory care infrastructure of a large urban health system and to discuss the outcomes of this service. Minnesota from September 2012 to December 2013. The health system has more than 50 primary care and specialty clinics. Eighteen credentialed MTM pharmacists are located in 16 different primary care and specialty settings, with the greatest number of pharmacists providing services in the internal medicine clinic. Home-based MTM was promoted throughout the clinics within the health system. Physicians, advanced practice providers, nurses, and pharmacists could refer patients to receive MTM in their homes. A home visit had the components of a clinic-based visit and was documented in the electronic health record (EHR); however, providing the service in the home allowed for a more direct assessment of environmental factors affecting medication use. Number of home MTM referrals, reason for referral and type of referring provider, number and type of medication-related problems (MRPs). In the first 15 months, 74 home visits were provided to 53 patients. Sixty-six percent of the patients were referred from the Internal Medicine Clinic. Referrals were also received from the senior care, coordinated care, and psychiatry clinics. Approximately 50% of referrals were made by physicians. More referrals (23%) were made by pharmacists compared with advanced practice providers, who made 21% of referrals. The top 3 reasons for referral were: nonadherence, transportation barriers, and the need for medication reconciliation with a home care nurse. Patients had a median of 3 MRPs with the most common (40%) MRP related to compliance. Home-based MTM is feasibly delivered within the ambulatory care infrastructure of a health system with sufficient provider engagement as demonstrated by referrals to the service. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  18. Measuring bacterial growth by refractive index tapered fiber optic biosensor.

    PubMed

    Zibaii, Mohammad Ismail; Kazemi, Alireza; Latifi, Hamid; Azar, Mahmoud Karimi; Hosseini, Seyed Masoud; Ghezelaiagh, Mohammad Hossein

    2010-12-02

    A single-mode tapered fiber optic biosensor was utilized for real-time monitoring of the Escherichia coli (E. coli K-12) growth in an aqueous medium. The applied fiber tapers were fabricated using heat-pulling method with waist diameter and length of 6-7μm and 3mm, respectively. The bacteria were immobilized on the tapered surface using Poly-l-Lysine. By providing the proper condition, bacterial population growth on the tapered surface increases the average surface density of the cells and consequently the refractive index (RI) of the tapered region would increase. The adsorption of the cells on the tapered fiber leads to changes in the optical characteristics of the taper. This affects the evanescent field leading to changes in optical throughput. The bacterial growth rate was monitored at room temperature by transmission of a 1558.17nm distributed feedback (DFB) laser through the tapered fiber. At the same condition, after determining the growth rate of E. coli by means of colony counting method, we compared the results with that obtained from the fiber sensor measurements. This novel sensing method, promises new application such as rapid analysis of the presence of bacteria. Copyright © 2010 Elsevier B.V. All rights reserved.

  19. The role of Mesozoic sedimentary basin tapers on the formation of Cenozoic crustal shortening structures and foredeep in the western Sichuan Basin, China

    NASA Astrophysics Data System (ADS)

    Wang, M.

    2017-12-01

    The foreland basin records important clues of tectonic and sedimentary process of mountain-building, thus to explore its dynamic mechanism on the formation is an important issue of the mountain-basin interaction. The Longmen Shan fold-and-thrust belt and its adjacent Sichuan basin located in the eastern margin of Tibetan Plateau, are one of the most-concerned regions of studying modern mountain-building and seismic process, and are also a natural laboratory of studying the dynamics of the formation and development of foreland basin. However, it still need further explore on the mechanics of the development of the Cenozoic foreland basin and thrust-belts in the western Sichuan Basin. The Longmen Shan thrust belt has experienced multi-stages of tectonics evolution, foreland basin formation and topography growth since Late Triassic, and whether the early formed basin architecture and large Mesozoic sedimentary basin taper can influence the formation and development of the Cenozoic foreland basin and thrust belts? To solve these issues, this project aim to focus on the Cenozoic foreland basin and internal crustal shortening structures in the western Sichuan basin, on the basis of growth critical wedge taper theory. We will reconstruct the shape of multi-phases of sedimentary basin tapers, the temporal-spatial distribution of crustal shortening and thrusting sequences, and analyze the control mechanism of Mesozoic sedimentary basin taper on the formation of Cenozoic foreland basins, and final explore the interaction between the tectonics geomorphology, stress field and dynamic propagation of foreland basin.

  20. Native and microwave-modified Terminalia mantaly gums as sustained-release and bioadhesive excipients in naproxen matrix tablet formulations.

    PubMed

    Odeniyi, Michael Ayodele; Oyedokun, Babatunde Mukhtar; Bamiro, Oluyemisi Adebowale

    2017-01-01

    Hydrophilic polymers provide a means of sustaining drug delivery. Native gums may be limited in function, but modification may improve their activity. The aim of the study was to evaluate native and modified forms of Terminalia mantaly gum for their sustained-release and bioadhesive properties. The native gum (NTM) was modified by microwave irradiation for 20 seconds (MTM20) and 60 seconds (MTM60) and characterized using microscopy, Fourier transform infrared spectroscopy (FTIR) and packing properties. The effects of the thermally induced molecular reorientation were determined. Tablet formulations of naproxen were produced by direct compression. The mechanical, bioadhesive and release properties of the formulations were determined. Irradiation of NTM improved the gum's flow properties, resulting in Carr's Index and Hausner's ratios lower than 16% and 1.25, respectively. Swelling studies showed that MTM20 and MTM60 had lower water absorption capacity and swelling index values, while packing properties improved upon irradiation, as depicted by lower tapped density values. FTIR spectra of samples showed that the irradiated gums were distinct from the native gums and did not interact with naproxen sodium. The gum's mechanical properties improved with MTM20 and MTM60 and sustained-release action of up 12 h was obtained. Inclusion of hydroxypropyl methylcellulose (HPMC) in the tablet formulations proved critical for bioadhesion. Microwave irradiation of native Terminalia mantaly gum improved the flow, mechanical and sustained-release properties of Naproxen tablets, and the addition of HPMC increased bioadhesion properties. The tablet properties of the native gum were significantly improved after 20 s of microwave irradiation.

  1. Ultraviolet, visible, and infrared laser delivery using laser-to-fiber coupling via a grazing-incidence-based hollow taper

    NASA Astrophysics Data System (ADS)

    Ilev, Ilko K.; Waynant, Ronald W.

    2001-01-01

    We present a novel all-optical-waveguide method for ultraviolet (UV), visible (VIS) and infrared (IR) laser delivery including a lens-free method of laser-to-fiber coupling using a simple uncoated glass hollow taper. Based on the grazing incidence effect, the hollow taper provides a way of direct launching, without any intermediate focusing elements, high power laser radiation into delivery fibers. Because of the mutual action of the nearly parallel laser excitation, the mode coupling process, and mode filtering effect, the hollow taper serves as a mode converter that transforms the highly multimode profile of the input laser emission into a high-quality Gaussian-shaped profile at the taper output. When the grazing incidence effect of the taper is applied to laser delivery, the maintenance of high reflectance coefficients in a wide spectral region allows to utilize the same uncoated hollow taper for laser radiation in the UV, VIS and IR ranges. Applying the experimental hollow-taper based delivery systems, we obtain high laser- to-taper and taper-to-fiber coupling efficiencies.

  2. Tunable thulium-doped fiber laser based on an abrupt-tapered in-fiber interferometer

    NASA Astrophysics Data System (ADS)

    Hernández-Arriaga, M. V.; Durán-Sánchez, M.; Ibarra-Escamilla, B.; Álvarez-Tamayo, R. I.; Santiago-Hernández, H.; Bello-Jiménez, M.; Kuzin, E. A.

    2017-11-01

    An experimental study of an all-fiber tunable thulium-doped fiber laser based on an abrupt-tapered in-fiber interferometer is presented. A microfiber filter with length of 6 mm and diameter of 20 μm is used to achieve single laser wavelength tuning in a range of 19.4 nm and dual-wavelength laser operation at 1761.8 and 1793.4 nm with a channel spacing of 31.6 nm. The abrupt-tapered structure allows multi-modal interference at the air-cladding interface. The proposed in-fiber interferometer exhibits characteristics of low cost and simple fabrication, making it suitable for practical applications in wavelength filtering and wavelength selection in all-fiber lasers.

  3. Geochemistry of Slow-Growing Corals: Reconstructing Sea Surface Temperature, Salinity and the North Atlantic Oscillation

    DTIC Science & Technology

    2007-06-01

    foraminifera, gastropods , and scaphopods) has been expressed as [Grossman and Ku, 1986]: 21 60 - 60w = -0.23 * (SST) +4.75 Eqn. (1) Slow growing corals...along the southeastern edge of the platform off John Smith’s Bay at 16m depth. (Figure adapted from World Ocean Circulation Experiment Newsletter...Atlantic Oscillation - Regional Temperatures and Precipitation, Science, 269, 676-679, 1995. Huybers, P., Multi-taper method coherence using adaptive

  4. 75 FR 438 - Notice of Invitation-Coal Exploration License Application MTM 99242

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-05

    ...] Notice of Invitation--Coal Exploration License Application MTM 99242 AGENCY: Bureau of Land Management... Energy Company in a program for the exploration of coal deposits owned by the United States of America in... section [[Page 439

  5. Use of manometric temperature measurements (MTM) to characterize the freeze-drying behavior of amorphous protein formulations.

    PubMed

    Johnson, Robert E; Oldroyd, Megan E; Ahmed, Saleem S; Gieseler, Henning; Lewis, Lavinia M

    2010-06-01

    The freeze-drying behavior and cake morphology of a model protein in an amorphous formulation were studied at varying protein concentrations using conservative (-25 degrees C) and aggressive (+25 degrees C) shelf temperatures at constant chamber pressure during primary drying. The two cycles were characterized by manometric temperature measurements (MTM) in a SMART freeze dryer that estimates the sublimation rate (dm/dt), product temperature at the freeze-drying front (T(p-MTM)) and product resistance (R(p)) during a run. The calculated sublimation rates (dm/dt) were 3-4 times faster in the aggressive cycle compared to the conservative cycle. For conservatively dried cakes R(p) increased with both dry layer thickness and protein concentration. For aggressively dried cakes (where freeze-drying occurs at the edge of microcollapse), R(p) also increased with protein concentration but was independent of the dry layer thickness. The sublimation rate was influenced by R(p), dry layer thickness and T(p-MTM) in the conservative cycle, but was governed mainly by T(p-MTM) in the aggressive cycle, where R(p) is independent of the dry layer thickness. The aggressively dried cakes had a more open and porous structure compared to their conservatively dried counterparts. (c) 2009 Wiley-Liss, Inc. and the American Pharmacists Association

  6. Imprint of the Atlantic Multidecadal Oscillation on Tree-Ring Widths in Northeastern Asia since 1568

    PubMed Central

    Wang, Xiaochun; Brown, Peter M.; Zhang, Yanni; Song, Laiping

    2011-01-01

    We present a new tree-ring reconstruction of the Atlantic Multidecadal Oscillation (AMO) spanning 1568–2007 CE from northeast Asia. Comparison of the instrumental AMO index, an existing tree-ring based AMO reconstruction, and this new record show strongly similar annual to multidecadal patterns of variation over the last 440 years. Warm phases of the AMO are related to increases in growth of Scots pine trees and moisture availability in northeast China and central eastern Siberia. Multi-tape method (MTM) and cross-wavelet analyses indicate that robust multidecadal (∼64–128 years) variability is present throughout the new proxy record. Our results have important implications concerning the influence of North Atlantic sea surface temperatures on East Asian climate, and provide support for the possibility of an AMO signature on global multidecadal climate variability. PMID:21818380

  7. Dominant covarying climate signals in the Southern Ocean and Antarctic Sea Ice influence during last three decades

    NASA Astrophysics Data System (ADS)

    Cerrone, Dario; Fusco, Giannetta; Simmonds, Ian; Aulicino, Giuseppe; Budillon, Giorgio

    2017-04-01

    A composite dataset (comprising geopotential height, sea surface temperature, zonal and meridional surface winds, precipitation, cloud cover, surface air temperature, latent plus sensible heat fluxes , and sea ice concentration) has been investigated with the aim of revealing the dominant timescales of variability from 1982 to 2013. Three covarying climate signals associated with variations in the sea ice distribution around Antarctica have been detected through the application of the Multiple-Taper Method with Singular Value Decomposition (MTM-SVD). Features of the established patterns of variation over the Southern Hemisphere (SH) extratropics have been identified in each of these three climate signals in the form of coupled or individual oscillations. The climate patterns considered here are the Southern Annular Mode (SAM), the Pacific-South America (PSA) teleconnection, the Semi-Annual Oscillation (SAO) and Zonal Wavenumber-3 (ZW3) mode. It is shown that most of the sea ice temporal variance is concentrated at the quasi-triennial scale resulting from the constructive superposition of the PSA and ZW3 patterns. In addition the combination of the SAM and SAO patterns is found to promote the interannual sea ice variations underlying a general change in the Southern Ocean atmospheric and oceanic circulations. These two modes of variability are also found consistent with the occurrence of the SAM+/PSA- or SAM-/PSA+ combinations, which could have favored the cooling of the sub-Antarctic and important changes in the Antarctic sea ice distribution since 2000.

  8. Development of a photogrammetric method of measuring tree taper outside bark

    Treesearch

    David R. Larsen

    2006-01-01

    A photogrammetric method is presented for measuring tree diameters outside bark using calibrated control ground-based digital photographs. The method was designed to rapidly collect tree taper information from subject trees for the development of tree taper equations. Software that is commercially available, but designed for a different purpose, can be readily adapted...

  9. Investigations of the fabrication and the surface-enhanced Raman scattering detection applications for tapered fiber probes prepared with the laser-induced chemical deposition method.

    PubMed

    Fan, Qunfang; Cao, Jie; Liu, Ye; Yao, Bo; Mao, Qinghe

    2013-09-01

    The process of depositing nanoparticles onto tapered fiber probes with the laser-induced chemical deposition method (LICDM) and the surface-enhanced Raman scattering (SERS) detection performance of the prepared probes are experimentally investigated in this paper. Our results show that the nanoparticle-deposited tapered fiber probes prepared with the LICDM method depend strongly on the value of the cone angle. For small-angle tapered probes the nanoparticle-deposited areas are only focused at the taper tips, because the taper surfaces are mainly covered by a relatively low-intensity evanescent field. By lengthening the reaction time or increasing the induced power or solution concentration, it is still possible to deposit nanoparticles on small-angle tapers with the light-scattering effect. With 4-aminothiophenol as the testing molecule, it was found that for given preparation conditions, the cone angles for the tapered probes with the highest SERS spectral intensities for different excitation laser powers are almost the same. However, such an optimal cone angle is determined by the combined effects of both the localized surface plasmon resonance strength and the transmission loss generated by the nanoparticles deposited.

  10. Fiber optic biosensor fabricated for measuring the growth rate of Escherichia coli K-12 in the aqueous

    NASA Astrophysics Data System (ADS)

    Zibaii, M. I.; Kazemi, A.; Latifi, H.; Karimi Azar, M.; Hosseini, S. M.; Ghezelaiagh, M. H.

    2010-09-01

    A single-mode tapered fiber optic biosensor was utilized for real-time monitoring of the Escherichia coli (E. coli K-12) growth in an aqueous medium. The applied fiber tapers were fabricated using heat-pulling method with waist diameter and length of 6-7μm and 3mm, respectively. The bacteria were immobilized on the tapered surface using Poly-L-Lysine. By providing the proper condition, bacterial population growth on the tapered surface increases the average surface density of the cells and consequently the refractive index (RI) of the tapered region would increase. The adsorption of the cells on the tapered fiber leads to changes in the optical characteristics of the taper. This affects the evanescent field leading to changes in optical throughput. The bacterial growth rate was monitored at room temperature by transmission of a 1558.17nm distributed feedback (DFB) laser through the tapered fiber. At the same condition, after determining the growth rate of E. coli by means of colony counting method, we compared the results with that obtained from the fiber sensor measurements. This novel sensing method, promises new application such as rapid analysis of the presence of bacteria.

  11. Long-term effects of systemic gene therapy in a canine model of myotubular myopathy.

    PubMed

    Elverman, Matthew; Goddard, Melissa A; Mack, David; Snyder, Jessica M; Lawlor, Michael W; Meng, Hui; Beggs, Alan H; Buj-Bello, Ana; Poulard, Karine; Marsh, Anthony P; Grange, Robert W; Kelly, Valerie E; Childers, Martin K

    2017-11-01

    X-linked myotubular myopathy (XLMTM), a devastating pediatric disease caused by the absence of the protein myotubularin, results from mutations in the MTM1 gene. While there is no cure for XLMTM, we previously reported effects of MTM1 gene therapy using adeno-associated virus (AAV) vector on muscle weakness and pathology in MTM1-mutant dogs. Here, we followed 2 AAV-infused dogs over 4 years. We evaluated gait, strength, respiration, neurological function, muscle pathology, AAV vector copy number (VCN), and transgene expression. Four years following AAV-mediated gene therapy, gait, respiratory performance, neurological function and pathology in AAV-infused XLMTM dogs remained comparable to their healthy littermate controls despite a decline in VCN and muscle strength. AAV-mediated gene transfer of MTM1 in young XLMTM dogs results in long-term expression of myotubularin transgene with normal muscular performance and neurological function in the absence of muscle pathology. These findings support a clinical trial in patients. Muscle Nerve 56: 943-953, 2017. © 2017 Wiley Periodicals, Inc.

  12. Challenges to Integrating Pharmacogenetic Testing into Medication Therapy Management

    PubMed Central

    Allen LaPointe, Nancy M.; Moaddeb, Jivan

    2015-01-01

    Background Some have proposed the integration of pharmacogenetic (PGx) testing into medication therapy management (MTM) to enable further refinement of treatment(s) to reduce risk of adverse responses and improve efficacy. PGx testing involves the analysis of genetic variants associated with therapeutic or adverse response and may be useful in enhancing the ability to identify ineffective and/or harmful drugs or drug combinations. This “enhanced” MTM might also reduce patient concerns about side effects and increase confidence that the medication is effective, addressing two key factors that impact patient adherence - concern and necessity. However, the feasibility and effectiveness of the integration of PGx testing into MTM in clinical practice has not yet been determined. Objectives In this paper, we consider some of the challenges to the integration and delivery of PGx testing in MTM services. What is already known about this subject While the addition of pharmacogenetic testing has been suggested, little literature exists exploring the challenges or feasibility of doing so. PMID:25803768

  13. Adiabatic tapered optical fiber fabrication in two step etching

    NASA Astrophysics Data System (ADS)

    Chenari, Z.; Latifi, H.; Ghamari, S.; Hashemi, R. S.; Doroodmand, F.

    2016-01-01

    A two-step etching method using HF acid and Buffered HF is proposed to fabricate adiabatic biconical optical fiber tapers. Due to the fact that the etching rate in second step is almost 3 times slower than the previous droplet etching method, terminating the fabrication process is controllable enough to achieve a desirable fiber diameter. By monitoring transmitted spectrum, final diameter and adiabaticity of tapers are deduced. Tapers with losses about 0.3 dB in air and 4.2 dB in water are produced. The biconical fiber taper fabricated using this method is used to excite whispering gallery modes (WGMs) on a microsphere surface in an aquatic environment. So that they are suitable to be used in applications like WGM biosensors.

  14. Monitoring the fabrication of tapered optical fibres

    NASA Astrophysics Data System (ADS)

    Mullaney, K.; Correia, R.; Staines, S. E.; James, S. W.; Tatam, R. P.

    2017-04-01

    A variety of optical methods to enhance the process of making optical fibre tapers are explored. A thermal camera was used to both refine the alignment of the optical components and optimize the laser power profile during the tapering process. The fibre transmission was measured to verify that the tapers had the requisite optical characteristics while the strain experienced by the fibre while tapering was assessed using an optical fibre Bragg grating. Using these techniques, adiabatic tapers were fabricated with a 2% insertion loss.

  15. Removal of carbamates and detoxification potential in a biomixture: Fungal bioaugmentation versus traditional use.

    PubMed

    Rodríguez-Rodríguez, Carlos E; Madrigal-León, Karina; Masís-Mora, Mario; Pérez-Villanueva, Marta; Chin-Pampillo, Juan Salvador

    2017-01-01

    The use of fungal bioaugmentation represents a promising way to improve the performance of biomixtures for the elimination of pesticides. The ligninolyitc fungus Trametes versicolor was employed for the removal of three carbamates (aldicarb, ALD; methomyl, MTM; and methiocarb, MTC) in defined liquid medium; in this matrix ALD and MTM showed similar half-lives (14d), nonetheless MTC exhibited a faster removal, with a half-life of 6.5d. Then the fungus was employed in the bioaugmentation of an optimized biomixture to remove the aforementioned carbamates plus carbofuran (CFN). Bioaugmented and non-bioaugmented systems removed over 99% ALD and MTM after 8d of treatment, nonetheless a slight initial delay in the removal was observed in the bioaugmented biomixtures (removal after 3d: ALD 87%/97%; MTM 86%/99%, in bioaugmented/non-bioaugmented systems). The elimination of the other carbamates was slower, but independent of the presence of the fungus: >98% for MTM after 35d and >99.5% for CFN after 22d. Though the bioaugmentation did not improve the removal capacity of the biomixture, it favored a lower production of transformation products at the first stages of the treatment, and in both cases, a marked decrease in the toxicity of the matrix was swiftly achieved along the process (from 435 to 448 TU to values <1TU in 16d). Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Welding-fume-induced transmission loss in tapered optical fibers

    NASA Astrophysics Data System (ADS)

    Yi, Ji-Haeng

    2015-09-01

    This paper presents a method for sensing welding fumes in real time. This method is based on the results of nanoparticle-induced optical-fiber loss experiments that show that the losses are determined by the nanoparticle density and the taper waist. The tapered fiber is obtained by applying heat radiated from hot quartz, and monitoring is done in real time. First, the durability of the tapered fiber during the welding process is proven. Then, the loss is categorized by using the sizes of welding fume particles. The sensitivity to welding fumes increases with increasing size of the particles; consequently, the dimension of the taper waist decreases.

  17. EFFECTS OF MOUNTAINTOP MINING/VALLEY FILL (MTM/VF) ON FUNCTIONAL INDICATORS IN APPALACHIAN HEADWATER STREAMS

    EPA Science Inventory

    The objectives of this poster were 1)to evaluate the impact of MTM/VF on the functional attributes SOD, soil/sediment respiration rate, soil/sediment DEA and dissolved trace gas concentrations across gradients of mining disturbance and hydrolgy and 2)compare these functional attr...

  18. Effects of the midnight temperature maximum observed in the thermosphere-ionosphere over the northeast of Brazil

    NASA Astrophysics Data System (ADS)

    Figueiredo, Cosme Alexandre O. B.; Buriti, Ricardo A.; Paulino, Igo; Meriwether, John W.; Makela, Jonathan J.; Batista, Inez S.; Barros, Diego; Medeiros, Amauri F.

    2017-08-01

    The midnight temperature maximum (MTM) has been observed in the lower thermosphere by two Fabry-Pérot interferometers (FPIs) at São João do Cariri (7.4° S, 36.5° W) and Cajazeiras (6.9° S, 38.6° W) during 2011, when the solar activity was moderate and the solar flux was between 90 and 155 SFU (1 SFU = 10-22 W m-2 Hz-1). The MTM is studied in detail using measurements of neutral temperature, wind and airglow relative intensity of OI630.0 nm (referred to as OI6300), and ionospheric parameters, such as virtual height (h'F), the peak height of the F2 region (hmF2), and critical frequency of the F region (foF2), which were measured by a Digisonde instrument (DPS) at Eusébio (3.9° S, 38.4° W; geomagnetic coordinates 7.31° S, 32.40° E for 2011). The MTM peak was observed mostly along the year, except in May, June, and August. The amplitudes of the MTM varied from 64 ± 46 K in April up to 144 ± 48 K in October. The monthly temperature average showed a phase shift in the MTM peak around 0.25 h in September to 2.5 h in December before midnight. On the other hand, in February, March, and April the MTM peak occurred around midnight. International Reference Ionosphere 2012 (IRI-2012) model was compared to the neutral temperature observations and the IRI-2012 model failed in reproducing the MTM peaks. The zonal component of neutral wind flowed eastward the whole night; regardless of the month and the magnitude of the zonal wind, it was typically within the range of 50 to 150 m s-1 during the early evening. The meridional component of the neutral wind changed its direction over the months: from November to February, the meridional wind in the early evening flowed equatorward with a magnitude between 25 and 100 m s-1; in contrast, during the winter months, the meridional wind flowed to the pole within the range of 0 to -50 m s-1. Our results indicate that the reversal (changes in equator to poleward flow) or abatement of the meridional winds is an important factor in the MTM generation. From February to April and from September to December, the h'F and the hmF2 showed an increase around 18:00-20:00 LT within a range between 300 and 550 km and reached a minimal height of about 200-300 km close to midnight; then the layer rose again by about 40 km or, sometimes, remained at constant height. Furthermore, during the winter months, the h'F and hmF2 showed a different behavior; the signature of the pre-reversal enhancement did not appear as in other months and the heights did not exceed 260 and 350 km. Our observation indicated that the midnight collapse of the F region was a consequence of the MTM in the meridional wind that was reflected in the height of the F region. Lastly, the behavior of the OI6300 showed, from February to April and from September to December, an increase in intensity around midnight or 1 h before, which was associated with the MTM, whereas, from May to August, the relative intensity was more intense in the early evening and decayed during the night.

  19. Comparison of estimates of hardwood bole volume using importance sampling, the centroid method, and some taper equations

    Treesearch

    Harry V., Jr. Wiant; Michael L. Spangler; John E. Baumgras

    2002-01-01

    Various taper systems and the centroid method were compared to unbiased volume estimates made by importance sampling for 720 hardwood trees selected throughout the state of West Virginia. Only the centroid method consistently gave volumes estimates that did not differ significantly from those made by importance sampling, although some taper equations did well for most...

  20. Evaluation of Eligibility Criteria Used to Identify Patients for Medication Therapy Management Services: A Retrospective Cohort Study in a Medicare Advantage Part D Population.

    PubMed

    Lee, Janet S; Yang, Jianing; Stockl, Karen M; Lew, Heidi; Solow, Brian K

    2016-01-01

    General eligibility criteria used by the Centers for Medicare & Medicaid Services (CMS) to identify patients for medication therapy management (MTM) services include having multiple chronic conditions, taking multiple Part D drugs, and being likely to incur annual drug costs that exceed a predetermined threshold. The performance of these criteria in identifying patients in greatest need of MTM services is unknown. Although there are numerous possible versions of MTM identification algorithms that satisfy these criteria, there are limited data that evaluate the performance of MTM services using eligibility thresholds representative of those used by the majority of Part D sponsors. To (a) evaluate the performance of the 2013 CMS MTM eligibility criteria thresholds in identifying Medicare Advantage Prescription Drug (MAPD) plan patients with at least 2 drug therapy problems (DTPs) relative to alternative criteria threshold levels and (b) identify additional patient risk factors significantly associated with the number of DTPs for consideration as potential future MTM eligibility criteria. All patients in the Medicare Advantage Part D population who had pharmacy eligibility as of December 31, 2013, were included in this retrospective cohort study. Study outcomes included 7 different types of DTPs: use of high-risk medications in the elderly, gaps in medication therapy, medication nonadherence, drug-drug interactions, duplicate therapy, drug-disease interactions, and brand-to-generic conversion opportunities. DTPs were identified for each member based on 6 months of most recent pharmacy claims data and 14 months of most recent medical claims data. Risk factors examined in this study included patient demographics and prior health care utilization in the most recent 6 months. Descriptive statistics were used to summarize patient characteristics and to evaluate unadjusted relationships between the average number of DTPs identified per patient and each risk factor. Quartile values identified in the study population for number of diseases, number of drugs, and annual spend were used as potential new criteria thresholds, resulting in 27 new MTM criteria combinations. The performance of each eligibility criterion was evaluated using sensitivity, specificity, positive predictive values (PPVs), and negative predictive values (NPVs). Patients identified with at least 2 DTPs were defined as those who would benefit from MTM services and were used as the gold standard. As part of a sensitivity analysis, patients identified with at least 1 DTP were used as the gold standard. Lastly, a multivariable negative binomial regression model was used to evaluate the relationship between each risk factor and the number of identified DTPs per patient while controlling for the patients' number of drugs, number of chronic diseases, and annual drug spend. A total of 2,578,336 patients were included in the study. The sensitivity, specificity, PPV, and NPV of CMS MTM criteria for the 2013 plan year were 15.3%, 95.6%, 51.3%, and 78.8%, respectively. Sensitivity and PPV improved when the drug count threshold increased from 8 to 10, and when the annual drug cost decreased from $3,144 to $2,239 or less. Results were consistent when at least 1 DTP was used as the gold standard. The adjusted rate of DTPs was significantly greater among patients identified with higher drug and disease counts, annual drug spend, and prior ER or outpatient or hospital visits. Patients with higher median household incomes who were male, younger, or white had significantly lower rates of DTPs. The performance of MTM eligibility criteria can be improved by increasing the threshold values for drug count while decreasing the threshold value for annual drug spend. Furthermore, additional risk factors, such as a recent ER or hospital visit, may be considered as potential MTM eligibility criteria.

  1. Coupled tapering/uptapering of Thirring type soliton pair in nonlinear media

    NASA Astrophysics Data System (ADS)

    Prasad, Shraddha; Dutta, Manoj Kumar; Sarkar, Ram Krishna

    2018-03-01

    The paper investigates coupled tapering/uptapering of Thirring type soliton pair, employing Beam Propagation Method. It is seen that, the pair uptapers in presence of losses and tapers in presence of gain. When the first beam has gain and the second one has losses in the nonlinear medium, the second beam induces uptapering in the first beam, while, first beam induces tapering in the second beam. When the medium provides gain/losses to only one of the two beams, the beam undergoes tapering/uptapering and also induces tapering/uptapering to the other loss less beam; however, magnitude of tapering/uptapering are different.

  2. Multiplex and simultaneous measurement of displacement and temperature using tapered fiber and fiber Bragg grating

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ji Chongke; Zhao Chunliu; Kang Juan

    2012-05-15

    A simple method to work out the multiplexing of tapered fiber based sensors is proposed and demonstrated. By cascading a tapered fiber with a fiber Bragg grating (FBG), the sensor head is provided with a wavelength identification, different FBGs provide the sensor heads with different reflective peaks and they can be distinguished in optical spectrum. By compositing several such sensor heads with a multi-channel beam splitter, a star-style topological structure sensor for multipoint sensing is achieved. At the same time, the output intensity at the peak wavelength is sensitive to one external physical parameter applied on the related FBG-cascaded taperedmore » fiber and the central wavelength of the peak is only sensitive to temperature, so that that parameter and temperature can be measured simultaneously. A sensor for dual-point measurement of the displacement and temperature simultaneously is experimentally demonstrated by using a 2 x 2 coupler in this paper. Experiment results show that the sensor works well and the largest sensitivities reach to 0.11 dB/{mu}m for displacement in the range of 0-400 {mu}m, and {approx}0.0097 nm/ deg. C for temperature between 20 deg. C and 70 deg. C.« less

  3. High-efficiency power transfer for silicon-based photonic devices

    NASA Astrophysics Data System (ADS)

    Son, Gyeongho; Yu, Kyoungsik

    2018-02-01

    We demonstrate an efficient coupling of guided light of 1550 nm from a standard single-mode optical fiber to a silicon waveguide using the finite-difference time-domain method and propose a fabrication method of tapered optical fibers for efficient power transfer to silicon-based photonic integrated circuits. Adiabatically-varying fiber core diameters with a small tapering angle can be obtained using the tube etching method with hydrofluoric acid and standard single-mode fibers covered by plastic jackets. The optical power transmission of the fundamental HE11 and TE-like modes between the fiber tapers and the inversely-tapered silicon waveguides was calculated with the finite-difference time-domain method to be more than 99% at a wavelength of 1550 nm. The proposed method for adiabatic fiber tapering can be applied in quantum optics, silicon-based photonic integrated circuits, and nanophotonics. Furthermore, efficient coupling within the telecommunication C-band is a promising approach for quantum networks in the future.

  4. Parametric optimization of multiple quality characteristics in laser cutting of Inconel-718 by using hybrid approach of multiple regression analysis and genetic algorithm

    NASA Astrophysics Data System (ADS)

    Shrivastava, Prashant Kumar; Pandey, Arun Kumar

    2018-06-01

    Inconel-718 has found high demand in different industries due to their superior mechanical properties. The traditional cutting methods are facing difficulties for cutting these alloys due to their low thermal potential, lower elasticity and high chemical compatibility at inflated temperature. The challenges of machining and/or finishing of unusual shapes and/or sizes in these materials have also faced by traditional machining. Laser beam cutting may be applied for the miniaturization and ultra-precision cutting and/or finishing by appropriate control of different process parameter. This paper present multi-objective optimization the kerf deviation, kerf width and kerf taper in the laser cutting of Incone-718 sheet. The second order regression models have been developed for different quality characteristics by using the experimental data obtained through experimentation. The regression models have been used as objective function for multi-objective optimization based on the hybrid approach of multiple regression analysis and genetic algorithm. The comparison of optimization results to experimental results shows an improvement of 88%, 10.63% and 42.15% in kerf deviation, kerf width and kerf taper, respectively. Finally, the effects of different process parameters on quality characteristics have also been discussed.

  5. Automatic identification of resting state networks: an extended version of multiple template-matching

    NASA Astrophysics Data System (ADS)

    Guaje, Javier; Molina, Juan; Rudas, Jorge; Demertzi, Athena; Heine, Lizette; Tshibanda, Luaba; Soddu, Andrea; Laureys, Steven; Gómez, Francisco

    2015-12-01

    Functional magnetic resonance imaging in resting state (fMRI-RS) constitutes an informative protocol to investigate several pathological and pharmacological conditions. A common approach to study this data source is through the analysis of changes in the so called resting state networks (RSNs). These networks correspond to well-defined functional entities that have been associated to different low and high brain order functions. RSNs may be characterized by using Independent Component Analysis (ICA). ICA provides a decomposition of the fMRI-RS signal into sources of brain activity, but it lacks of information about the nature of the signal, i.e., if the source is artifactual or not. Recently, a multiple template-matching (MTM) approach was proposed to automatically recognize RSNs in a set of Independent Components (ICs). This method provides valuable information to assess subjects at individual level. Nevertheless, it lacks of a mechanism to quantify how much certainty there is about the existence/absence of each network. This information may be important for the assessment of patients with severely damaged brains, in which RSNs may be greatly affected as a result of the pathological condition. In this work we propose a set of changes to the original MTM that improves the RSNs recognition task and also extends the functionality of the method. The key points of this improvement is a standardization strategy and a modification of method's constraints that adds flexibility to the approach. Additionally, we also introduce an analysis to the trustworthiness measurement of each RSN obtained by using template-matching approach. This analysis consists of a thresholding strategy applied over the computed Goodness-of-Fit (GOF) between the set of templates and the ICs. The proposed method was validated on 2 two independent studies (Baltimore, 23 healthy subjects and Liege, 27 healthy subjects) with different configurations of MTM. Results suggest that the method will provide complementary information for characterization of RSNs at individual level.

  6. Ultra-short beam expander with segmented curvature control: the emergence of a semi-lens

    DOE PAGES

    Abbaslou, Siamak; Gatdula, Robert; Lu, Ming; ...

    2017-01-01

    We introduce direct curvature control in designing a segmented beam expander, and explore novel design possibilities for ultra-compact beam expanders. Assisted by the particle swarm optimization algorithm, we search for an optimal curvature-controlled multi-segment taper that maintains width continuity. Counterintuitively, the optimization yields a structure with abrupt width discontinuity and width compression features. Through spatial phase and parameterized analysis, a semi-lens feature is revealed that helps to flatten the wavefront at the output end for higher coupling efficiency. Such functionality cannot be achieved by normal tapers in a short distance. The structure is fabricated and characterized experimentally. By a figuremore » of merit that accounts for expansion ratio, length, and efficiency, this structure outperforms an adiabatic taper by 9 times.« less

  7. 77 FR 71822 - Notice of Invitation-Coal Exploration License Application MTM 103852, MT

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-04

    ...] Notice of Invitation--Coal Exploration License Application MTM 103852, MT AGENCY: Bureau of Land... Ambre Energy on a pro rata cost sharing basis in a program for the exploration of coal deposits owned by... program is to gain additional geologic knowledge of the coal underlying the exploration area for the...

  8. Effects of Rosemary Oil (Rosmarinus officinalis) On The Shelf-Life of Minced Rainbow Trout (Oncorhynchus mykiss) during Refrigerated Storage

    PubMed Central

    Peiretti, Pier Giorgio; Gai, Francesco; Ortoffi, Marco; Aigotti, Riccardo; Medana, Claudio

    2012-01-01

    The effects of three concentrations (0.2%, 1% and 3%) of rosemary oil (RO) on the freshness indicators, oxidative stability, fatty acid and biogenic amine (BA) contents of minced rainbow trout muscle (MTM) were investigated after different periods of storage (three and nine days) at 4 ± 1 °C. Moreover, the terpene and sesquiterpene contents in the treated MTM were also measured. RO treatment improves the pH, oxidative stability of the lipids and the FA profile, which resulted in a significant extension of MTM shelf-life. Storage time influenced all freshness indicators, with the exception of yellowness and chroma. Treatment with RO had a positive effect, leading to low BA content, especially putrescine, cadaverine, tyramine and histamine. Differences in BA were also found to be due to storage time, with the exception of spermidine, which was not influenced by time. Moreover, the presence of the terpenoid fraction of RO in MTM improved the quality of this ready-to-cook fish food. PMID:28239089

  9. Donating money is not the only way to sustain cooperation in public goods game

    NASA Astrophysics Data System (ADS)

    Chen, Tong; Wu, Zheng-Hong; Wang, Le

    Most of the previous studies research cooperation mainly based on donating money in social public goods games. Owing to the lack of income, some people prefer to donate time instead of money to promote the activity, in our daily life. Motivated by this fact, we here investigate the influence of the encouragement of donating time on the evolution of cooperation based on village opera. In our study, we set up two models: one is money-only model (MOM). Donating money is the only choice in MOM. The other is money-time model (MTM). Besides donating money, donating time is an alternative in MTM. Through numerical simulations, we find that compared to MOM, MTM has a faster speed to reach cooperation equilibrium and cost advantage to sustain the same cooperation level, without the effects of income, reputation, satisfaction, emotion and maximum nonmonetary input. However, it should be noted that MTM is better than MOM in a moderate interval of general budget V. Our results provide stark evidence that the encouragement of donating time can promote and sustain cooperation better than only donating money.

  10. The Association between Outpatient Buprenorphine Detoxification Duration and Clinical Treatment Outcomes: A Review

    PubMed Central

    Sigmon, Stacey C.; Strain, Eric C.; Heil, Sarah H.; Higgins, Stephen T.

    2011-01-01

    Background The association between buprenorphine taper duration and treatment outcomes is not well understood. This review evaluated whether duration of outpatient buprenorphine taper is significantly associated with treatment outcomes. Methods Studies that were published in peer-reviewed journals, administered buprenorphine as an outpatient taper to opioid-dependent participants, and provided data on at least one of three primary treatment outcome measures (opioid abstinence, retention, peak withdrawal severity) were reviewed. Primary treatment outcomes were evaluated as a function of taper duration using hierarchical linear regressions using pre-taper maintenance as a cofactor. Results Twenty-eight studies were reviewed. Taper duration significantly predicted percent of opioid-negative samples provided during treatment, however pre-taper maintenance period predicted percent participants abstinent on the final day of treatment. High rates of relapse were reported. No significant association between taper duration and retention in treatment or peak withdrawal severity was observed. Conclusion The data reviewed here suggest taper duration is associated with opioid abstinence achieved during detoxification but not with other markers of treatment outcome. The reviewed studies varied widely on several parameters (e.g., frequency of urinalysis testing, provision of ancillary medications) that may influence treatment outcome and thus could have interfered with the ability to identify relationships between taper duration and outcomes. Future studies evaluating opioid detoxification should utilize rigorous experimental methods and report a wider range of outcome measures in order to help advance our understanding of the association between taper duration and treatment outcomes. PMID:21741781

  11. Detection of the secondary meridional circulation associated with the quasi-biennial oscillation

    NASA Astrophysics Data System (ADS)

    Ribera, P.; PeñA-Ortiz, C.; Garcia-Herrera, R.; Gallego, D.; Gimeno, L.; HernáNdez, E.

    2004-09-01

    The quasi-biennial oscillation (QBO) signal in stratospheric zonal and meridional wind, temperature, and geopotential height fields is analyzed based on the use of the National Centers for Environmental Prediction (NCEP) reanalysis (1958-2001). The multitaper method-singular value decomposition (MTM-SVD), a multivariate frequency domain analysis method, is used to detect significant and spatially coherent narrowband oscillations. The QBO is found as the most intense signal in the stratospheric zonal wind. Then, the MTM-SVD method is used to determine the patterns induced by the QBO at every stratospheric level and data field. The secondary meridional circulation associated with the QBO is identified in the obtained patterns. This circulation can be characterized by negative (positive) temperature anomalies associated with adiabatic rising (sinking) motions over zones of easterly (westerly) wind shear and over the subtropics and midlatitudes, while meridional convergence and divergence levels are found separated by a level of maximum zonal wind shear. These vertical and meridional motions form quasi-symmetric circulation cells over both hemispheres, though less intense in the Southern Hemisphere.

  12. Ion source and beam guiding studies for an API neutron generator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sy, A.; Ji, Q.; Persaud, A.

    2013-04-19

    Recently developed neutron imaging methods require high neutron yields for fast imaging times and small beam widths for good imaging resolution. For ion sources with low current density to be viable for these types of imaging methods, large extraction apertures and beam focusing must be used. We present recent work on the optimization of a Penning-type ion source for neutron generator applications. Two multi-cusp magnet configurations have been tested and are shown to increase the extracted ion current density over operation without multi-cusp magnetic fields. The use of multi-cusp magnetic confinement and gold electrode surfaces have resulted in increased ionmore » current density, up to 2.2 mA/cm{sup 2}. Passive beam focusing using tapered dielectric capillaries has been explored due to its potential for beam compression without the cost and complexity issues associated with active focusing elements. Initial results from first experiments indicate the possibility of beam compression. Further work is required to evaluate the viability of such focusing methods for associated particle imaging (API) systems.« less

  13. Potential cost savings of medication therapy management in safety-net clinics.

    PubMed

    Truong, Hoai-An; Groves, C Nicole; Congdon, Heather B; Dang, Diem-Thanh Tanya; Botchway, Rosemary; Thomas, Jennifer

    2015-01-01

    To evaluate potential cost savings based on estimated cost avoidance from medication therapy management (MTM) services delivered in safety-net clinics over 4 years. High-risk patients taking multiple medications and with chronic conditions were referred for MTM services in primary care safety-net clinics in Maryland from October 1, 2009, to September 30, 2013. Medication-related problems (MRPs) were identified and pharmacists' costs determined to evaluate the estimated cost savings and return on investment (ROI). A range of potential economic outcomes for each MRP identified was assigned to a cost avoidance for outpatient visit, urgent care visit, emergency department visit, and/or hospitalization. Over 4 years, 246 patients received MTM, nearly 2,100 medications were reviewed, and 814 MRPs were identified. The most common MRPs identified were subtherapeutic doses, nonadherence, and untreated indications, with respective prevalences of 38%, 19%, and 16%. The corresponding costs of medical services were estimated at $115,220-$614,570 for all MRPs identified, yielding a mean of $141.55-$755.00 per identified MRP. Pharmacists' expenses for encounters were calculated at a total expenditure of $57,307.50 for 16,965 minutes. ROI based on the time spent during billable face-to-face encounters ranged from 1:5 to 1:25. Pharmacist-provided MTM in safety-net clinics yielded potential economic benefits to the organization. The Primary Care Coalition of Montgomery County plans to expand MTM services to additional clinics to improve patient care and increase cost savings through preventable medical services.

  14. Geologic mapping of Argyre Planitia

    NASA Technical Reports Server (NTRS)

    Gorsline, Donn S.; Parker, Timothy J.

    1995-01-01

    This report describes the results from the geologic mapping of the central and southern Argyre basin of Mars. At the Mars Geologic Mapper's Meeting in Flagstaff during July, 1993, Dave Scott (United States Geological Survey, Mars Geologic Mapping Steering Committee Chair) recommended that all four quadrangles be combined into a single 1:1,000,000 scale map for publication. It was agreed that this would be cost-effective and that the decrease in scale would not compromise the original science goals of the mapping. Tim Parker completed mapping on the 1:500,000 scale base maps, for which all the necessary materials had already been produced, and included the work as a chapter in his dissertation, which was completed in the fall of 1994. Geologic mapping of the two southernmost quadrangles (MTM -55036 and MTM -55043; MTM=Mars Transverse Mercator) was completed as planned during the first year of work. These maps and a detailed draft of the map text were given a preliminary review by Dave Scott during summer, 1993. Geologic mapping of the remaining two quadrangles (MTM -50036 and MTM -50043) was completed by summer, 1994. Results were described at the Mars Geologic Mappers Meeting, held in Pocatello, Idaho, during July, 1994. Funds for the third and final year of the project have been transferred to the Jet Propulsion Laboratory, where Tim Parker will revise and finalize all maps and map text for publication by the United States Geological Survey at the 1:1,000,000 map scale.

  15. Are residents of mountain-top mining counties more likely to have infants with birth defects? The West Virginia experience.

    PubMed

    Lamm, Steven H; Li, Ji; Robbins, Shayhan A; Dissen, Elisabeth; Chen, Rusan; Feinleib, Manning

    2015-02-01

    Pooled 1996 to 2003 birth certificate data for four central states in Appalachia indicated higher rates of infants with birth defects born to residents of counties with mountain-top mining (MTM) than born to residents of non-mining-counties (Ahern 2011). However, those analyses did not consider sources of uncertainty such as unbalanced distributions or quality of data. Quality issues have been a continuing problem with birth certificate analyses. We used 1990 to 2009 live birth certificate data for West Virginia to reassess this hypothesis. Forty-four hospitals contributed 98% of the MTM-county births and 95% of the non-mining-county births, of which six had more than 1000 births from both MTM and nonmining counties. Adjusted and stratified prevalence rate ratios (PRRs) were computed both by using Poisson regression and Mantel-Haenszel analysis. Unbalanced distribution of hospital births was observed by mining groups. The prevalence rate of infants with reported birth defects, higher in MTM-counties (0.021) than in non-mining-counties (0.015), yielded a significant crude PRR (cPRR = 1.43; 95% confidence interval [CI] = 1.36-1.52) but a nonsignificant hospital-adjusted PRR (adjPRR = 1.08; 95% CI = 0.97-1.20; p = 0.16) for the 44 hospitals. So did the six hospital data analysis ([cPRR = 2.39; 95% CI = 2.15-2.65] and [adjPRR = 1.01; 95% CI, 0.89-1.14; p = 0.87]). No increased risk of birth defects was observed for births from MTM-counties after adjustment for, or stratification by, hospital of birth. These results have consistently demonstrated that the reported association between birth defect rates and MTM coal mining was a consequence of data heterogeneity. The data do not demonstrate evidence of a "Mountain-top Mining" effect on the prevalence of infants with reported birth defects in WV. © 2014 Wiley Periodicals, Inc.

  16. Octave spanning supercontinuum in an As₂S₃ taper using ultralow pump pulse energy.

    PubMed

    Hudson, Darren D; Dekker, Stephen A; Mägi, Eric C; Judge, Alexander C; Jackson, Stuart D; Li, Enbang; Sanghera, J S; Shaw, L B; Aggarwal, I D; Eggleton, Benjamin J

    2011-04-01

    An octave spanning spectrum is generated in an As₂S₃ taper via 77 pJ pulses from an ultrafast fiber laser. Using a previously developed tapering method, we construct a 1.3 μm taper that has a zero-dispersion wavelength around 1.4 μm. The low two-photon absorption of sulfide-based chalcogenide fiber allows for higher input powers than previous efforts in selenium-based chalcogenide tapered fibers. This higher power handling capability combined with input pulse chirp compensation allows an octave spanning spectrum to be generated directly from the taper using the unamplified laser output.

  17. Stability of the mode-locking regime in tapered quantum-dot lasers

    NASA Astrophysics Data System (ADS)

    Bardella, P.; Drzewietzki, L.; Rossetti, M.; Weber, C.; Breuer, S.

    2018-02-01

    We study numerically and experimentally the role of the injection current and reverse bias voltage on the pulse stability of tapered, passively mode-locked, Quantum Dot (QD) lasers. By using a multi-section delayed differential equation and introducing in the model the QD inhomogenous broadening, we are able to predict the onset of leading and trailing edge instabilities in the emitted pulse trains and to identify specific trends of stability in dependence on the laser biasing conditions. The numerical results are confirmed experimentally trough amplitude and timing stability analysis of the pulses.

  18. 78 FR 76319 - Notice of Invitation-Coal Exploration License Application MTM 106757, Montana

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-17

    ...] Notice of Invitation--Coal Exploration License Application MTM 106757, Montana AGENCY: Bureau of Land... Signal Peak Energy, LLC on a pro rata cost sharing basis in a program for the exploration of coal... Office coal Web site at http://www.blm.gov/mt/st/en/prog/energy/coal.html . A written notice to...

  19. 76 FR 31976 - Notice of Invitation-Coal Exploration License Application MTM 101688

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-02

    ...] Notice of Invitation--Coal Exploration License Application MTM 101688 AGENCY: Bureau of Land Management... Creek Coal Company on a pro rata cost sharing basis in a program for the exploration of coal deposits... notice to both the Bureau of Land Management (BLM) and the Spring Creek Coal Company as provided in the...

  20. 75 FR 62137 - Notice of Public Meeting; Proposed Alluvial Valley Floor Coal Exchange Public Interest Factors...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-07

    ...; MTM-99236] Notice of Public Meeting; Proposed Alluvial Valley Floor Coal Exchange Public Interest... (SMCRA) of 1977. This exchange (serial number MTM-99236) has been proposed by Jay Nance, Brett A... Director. [FR Doc. 2010-25060 Filed 10-6-10; 8:45 am] BILLING CODE 4310-DN-P ...

  1. Spectrum online-tunable Mach-Zehnder interferometer based on step-like tapers and its refractive index sensing characteristics

    NASA Astrophysics Data System (ADS)

    Zhao, Yong; Chen, Mao-qing; Xia, Feng; Hu, Hai-feng

    2017-11-01

    A novel refractive index (RI) sensor based on an asymmetrical Mach-Zehnder interferometer (MZI) with two different step-like tapers is proposed. The step-like taper is fabricated by fusion splicing two half tapers with an appropriate offset. By further applying offset and discharging to the last fabricated step-like taper of MZI, influence of taper parameters on interference spectrum is investigated using only one device. This simple technique provides an on-line method to sweep parameters of step-like tapers and speeds up the optimization process of interference spectrum, meanwhile. In RI sensing experiment, the sensor has a high sensitivity of -185.79 nm/RIU (refractive index unit) in the RI range of 1.3333-1.3673.

  2. Adiabatically tapered splice for selective excitation of the fundamental mode in a multimode fiber.

    PubMed

    Jung, Yongmin; Jeong, Yoonchan; Brambilla, Gilberto; Richardson, David J

    2009-08-01

    We propose a simple and effective method to selectively excite the fundamental mode of a multimode fiber by adiabatically tapering a fusion splice to a single-mode fiber. We experimentally demonstrate the method by adiabatically tapering splice (taper waist=15 microm, uniform length=40 mm) between single-mode and multimode fiber and show that it provides a successful mode conversion/connection and allows for almost perfect fundamental mode excitation in the multimode fiber. Excellent beam quality (M(2) approximately 1.08) was achieved with low loss and high environmental stability.

  3. A design for living technology: experiments with the mind time machine.

    PubMed

    Ikegami, Takashi

    2013-01-01

    Living technology aims to help people expand their experiences in everyday life. The environment offers people ways to interact with it, which we call affordances. Living technology is a design for new affordances. When we experience something new, we remember it by the way we perceive and interact with it. Recent studies in neuroscience have led to the idea of a default mode network, which is a baseline activity of a brain system. The autonomy of artificial life must be understood as a sort of default mode that self-organizes its baseline activity, preparing for its external inputs and its interaction with humans. I thus propose a method for creating a suitable default mode as a design principle for living technology. I built a machine called the mind time machine (MTM), which runs continuously for 10 h per day and receives visual data from its environment using 15 video cameras. The MTM receives and edits the video inputs while it self-organizes the momentary now. Its base program is a neural network that includes chaotic dynamics inside the system and a meta-network that consists of video feedback systems. Using this system as the hardware and a default mode network as a conceptual framework, I describe the system's autonomous behavior. Using the MTM as a testing ground, I propose a design principle for living technology.

  4. Inhibition of Activin Receptor Type IIB Increases Strength and Lifespan in Myotubularin-Deficient Mice

    PubMed Central

    Lawlor, Michael W.; Read, Benjamin P.; Edelstein, Rachel; Yang, Nicole; Pierson, Christopher R.; Stein, Matthew J.; Wermer-Colan, Ariana; Buj-Bello, Anna; Lachey, Jennifer L.; Seehra, Jasbir S.; Beggs, Alan H.

    2011-01-01

    X-linked myotubular myopathy (XLMTM) is a congenital disorder caused by deficiency of the lipid phosphatase, myotubularin. Patients with XLMTM often have severe perinatal weakness that requires mechanical ventilation to prevent death from respiratory failure. Muscle biopsy specimens from patients with XLMTM exhibit small myofibers with central nuclei and central aggregations of organelles in many cells. It was postulated that therapeutically increasing muscle fiber size would cause symptomatic improvement in myotubularin deficiency. Recent studies have elucidated an important role for the activin-receptor type IIB (ActRIIB) in regulation of muscle growth and have demonstrated that ActRIIB inhibition results in significant muscle hypertrophy. To evaluate whether promoting muscle hypertrophy can attenuate symptoms resulting from myotubularin deficiency, the effect of ActRIIB-mFC treatment was determined in myotubularin-deficient (Mtm1δ4) mice. Compared with wild-type mice, untreated Mtm1δ4 mice have decreased body weight, skeletal muscle hypotrophy, and reduced survival. Treatment of Mtm1δ4 mice with ActRIIB-mFC produced a 17% extension of lifespan, with transient increases in weight, forelimb grip strength, and myofiber size. Pathologic analysis of Mtm1δ4 mice during treatment revealed that ActRIIB-mFC produced marked hypertrophy restricted to type 2b myofibers, which suggests that oxidative fibers in Mtm1δ4 animals are incapable of a hypertrophic response in this setting. These results support ActRIIB-mFC as an effective treatment for the weakness observed in myotubularin deficiency. PMID:21281811

  5. Buckling analysis of non-prismatic columns based on modified vibration modes

    NASA Astrophysics Data System (ADS)

    Rahai, A. R.; Kazemi, S.

    2008-10-01

    In this paper, a new procedure is formulated for the buckling analysis of tapered column members. The calculation of the buckling loads was carried out by using modified vibrational mode shape (MVM) and energy method. The change of stiffness within a column is characterized by introducing a tapering index. It is shown that, the changes in the vibrational mode shapes of a tapered column can be represented by considering a linear combination of various modes of uniform-section columns. As a result, by making use of these modified mode shapes (MVM) and applying the principle of stationary total potential energy, the buckling load of tapered columns can be obtained. Several numerical examples on tapered columns demonstrate the accuracy and efficiency of the proposed analytical method.

  6. CROSS-DISCIPLINARY PHYSICS AND RELATED AREAS OF SCIENCE AND TECHNOLOGY: Novel Route to Fabrication of Metal-Sandwiched Nanoscale Tapered Structures

    NASA Astrophysics Data System (ADS)

    Zhang, Yang; Yu, Da-Peng

    2009-08-01

    Tapered dielectric structures in metal have exhibited extraordinary performance in both surface plasmon polariton (SPP) waveguiding and SPP focusing. This is crucial to plasmonic research and industrial plasmonic device integration. We present a method that facilitates easy fabrication of smooth-surfaced sub-micron tapered structures in large scale simply with electron beam lithography (EBL). When a PMMA layer is spin-coated on previously-EBL-defined PMMA structures, steep edges can be transformed into a declining slope to form tapered PMMA structures, scaled from 10 nm to 1000 nm. Despite the simplicity of our method, patterns with PMMA surface smoothness can be well-positioned and replicated in large numbers, which therefore gives scientists easy access to research on the properties of tapered structures.

  7. Attracting Students to Space Science Fields: Mission to Mars

    NASA Astrophysics Data System (ADS)

    Congdon, Donald R.; Lovegrove, William P.; Samec, Ronald G.

    Attracting high school students to space science is one of the main goals of Bob Jones University's annual Mission to Mars (MTM). MTM develops interest in space exploration through a highly realistic simulated trip to Mars. Students study and learn to appreciate the challenges of space travel including propulsion life support medicine planetary astronomy psychology robotics and communication. Broken into teams (Management Spacecraft Design Communications Life Support Navigation Robotics and Science) they address the problems specific to each aspect of the mission. Teams also learn to interact and recognize that a successful mission requires cooperation. Coordinated by the Management Team the students build a spacecraft and associated apparatus connect computers and communications equipment train astronauts on the mission simulator and program a Pathfinder-type robot. On the big day the astronauts enter the spacecraft as Mission Control gets ready to support them through the expected and unexpected of their mission. Aided by teamwork the astronauts must land on Mars perform their scientific mission on a simulated surface of mars and return home. We see the success of MTM not only in successful missions but in the students who come back year after year for another MTM.

  8. Racial and Ethnic Disparities in Meeting MTM Eligibility Criteria Based on Star Ratings Compared with the Medicare Modernization Act.

    PubMed

    Spivey, Christina A; Wang, Junling; Qiao, Yanru; Shih, Ya-Chen Tina; Wan, Jim Y; Kuhle, Julie; Dagogo-Jack, Samuel; Cushman, William C; Chisholm-Burns, Marie

    2018-02-01

    Previous research found racial and ethnic disparities in meeting medication therapy management (MTM) eligibility criteria implemented by the Centers for Medicare & Medicaid Services (CMS) in accordance with the Medicare Modernization Act (MMA). To examine whether alternative MTM eligibility criteria based on the CMS Part D star ratings quality evaluation system can reduce racial and ethnic disparities. This study analyzed the Beneficiary Summary File and claims files for Medicare beneficiaries linked to the Area Health Resource File. Three million Medicare beneficiaries with continuous Parts A, B, and D enrollment in 2012-2013 were included. Proposed star ratings criteria included 9 existing medication safety and adherence measures developed mostly by the Pharmacy Quality Alliance. Logistic regression and the Blinder-Oaxaca approach were used to test disparities in meeting MMA and star ratings eligibility criteria across racial and ethnic groups. Multinomial logistic regression was used to examine whether there was a disparity reduction by comparing individuals who were MTM-eligible under MMA but not under star ratings criteria and those who were MTM-eligible under star ratings criteria but not under the MMA. Concerning MMA-based MTM criteria, main and sensitivity analyses were performed to represent the entire range of the MMA eligibility thresholds reported by plans in 2009, 2013, and proposed by CMS in 2015. Regarding star ratings criteria, meeting any 1 of the 9 measures was examined as the main analysis, and various measure combinations were examined as the sensitivity analyses. In the main analysis, adjusted odds ratios for non-Hispanic blacks (backs) and Hispanics to non-Hispanic whites (whites) were 1.394 (95% CI = 1.375-1.414) and 1.197 (95% CI = 1.176-1.218), respectively, under star ratings. Blacks were 39.4% and Hispanics were 19.7% more likely to be MTM-eligible than whites. Blacks and Hispanics were less likely to be MTM-eligible than whites in some sensitivity analyses. Disparities were not completely explained by differences in patient characteristics based on the Blinder-Oaxaca approach. The multinomial logistic regression of each main analysis found significant adjusted relative risk ratios (RRR) between whites and blacks for 2009 (RRR = 0.459, 95% CI = 0.438-0.481); 2013 (RRR = 0.449, 95% CI = 0.434-0.465); and 2015 (RRR = 0.436, 95% CI = 0.425-0.446) and between whites and Hispanics for 2009 (RRR = 0.559, 95% CI = 0.528-0.593); 2013 (RRR = 0.544, 95% CI = 0.521-0.569); and 2015 (RRR = 0.503, 95% CI = 0.488-0.518). These findings indicate a significant reduction in racial and ethnic disparities when using star ratings eligibility criteria; for example, black-white disparities in the likelihood of meeting MTM eligibility criteria were reduced by 55.1% based on star ratings compared with MMA in 2013. Similar patterns were found in most sensitivity and disease-specific analyses. This study found that minorities were more likely than whites to be MTM-eligible under the star ratings criteria. In addition, MTM eligibility criteria based on star ratings would reduce racial and ethnic disparities associated with MMA in the general Medicare population and those with specific chronic conditions. Research reported in this publication was supported by the National Institute on Aging of the National Institutes of Health under award number R01AG049696. The content of this study is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health. Cushman reports an Eli Lilly grant and uncompensated consulting for Takeda Pharmaceuticals outside this work. The other authors have no potential conflicts of interest to report. Study concept and design were contributed by Wang and Shih, along with Wan, Kuhle, Spivey, and Cushman. Wang, Qiao, and Wan took the lead in data collection, with assistance from the other authors. Data interpretation was performed by Wang, Kuhle, and Qiao, with assistance from the other authors. The manuscript was written by Spivey and Qiao, along with the other authors, and revised by Cushman, Dagogo-Jack, and Chisholm-Burns, along with the other authors.

  9. Damped gyroscopic effects and axial-flexural-torsional coupling using spinning finite elements for wind-turbine blades characterization

    NASA Astrophysics Data System (ADS)

    Velazquez, Antonio; Swartz, R. Andrew

    2013-04-01

    Renewable energy sources like wind are important technologies, useful to alleviate for the current fossil-fuel crisis. Capturing wind energy in a more efficient way has resulted in the emergence of more sophisticated designs of wind turbines, particularly Horizontal-Axis Wind Turbines (HAWTs). To promote efficiency, traditional finite element methods have been widely used to characterize the aerodynamics of these types of multi-body systems and improve their design. Given their aeroelastic behavior, tapered-swept blades offer the potential to optimize energy capture and decrease fatigue loads. Nevertheless, modeling special complex geometries requires huge computational efforts necessitating tradeoffs between faster computation times at lower cost, and reliability and numerical accuracy. Indeed, the computational cost and the numerical effort invested, using traditional FE methods, to reproduce dependable aerodynamics of these complex-shape beams are sometimes prohibitive. A condensed Spinning Finite Element (SFE) method scheme is presented in this study aimed to alleviate this issue by means of modeling wind-turbine rotor blades properly with tapered-swept cross-section variations of arbitrary order via Lagrangian equations. Axial-flexural-torsional coupling is carried out on axial deformation, torsion, in-plane bending and out-of-plane bending using super-convergent elements. In this study, special attention is paid for the case of damped yaw effects, expressed within the described skew-symmetric damped gyroscopic matrix. Dynamics of the model are analyzed by achieving modal analysis with complex-number eigen-frequencies. By means of mass, damped gyroscopic, and stiffness (axial-flexural-torsional coupling) matrix condensation (order reduction), numerical analysis is carried out for several prototypes with different tapered, swept, and curved variation intensities, and for a practical range of spinning velocities at different rotation angles. A convergence study for the resulting natural frequencies is performed to evaluate the dynamic collateral effects of tapered-swept blade profiles in spinning motion using this new model. Stability analysis in boundary conditions of the postulated model is achieved to test the convergence and integrity of the mathematical model. The proposed framework presumes to be particularly suitable to characterize models with complex-shape cross-sections at low computation cost.

  10. Tapered fiber optical tweezers for microscopic particle trapping: fabrication and application

    NASA Astrophysics Data System (ADS)

    Liu, Zhihai; Guo, Chengkai; Yang, Jun; Yuan, Libo

    2006-12-01

    A novel single tapered fiber optical tweezers is proposed and fabricated by heating and drawing technology. The microscopic particle tapping performance of this special designed tapered fiber probe is demonstrated and investigated. The distribution of the optical field emerging from the tapered fiber tip is numerically calculated based on the beam propagation method. The trapping force FDTD analysis results, both axial and transverse, are also given.

  11. Automated airway evaluation system for multi-slice computed tomography using airway lumen diameter, airway wall thickness and broncho-arterial ratio

    NASA Astrophysics Data System (ADS)

    Odry, Benjamin L.; Kiraly, Atilla P.; Novak, Carol L.; Naidich, David P.; Lerallut, Jean-Francois

    2006-03-01

    Pulmonary diseases such as bronchiectasis, asthma, and emphysema are characterized by abnormalities in airway dimensions. Multi-slice computed tomography (MSCT) has become one of the primary means to depict these abnormalities, as the availability of high-resolution near-isotropic data makes it possible to evaluate airways at oblique angles to the scanner plane. However, currently, clinical evaluation of airways is typically limited to subjective visual inspection only: systematic evaluation of the airways to take advantage of high-resolution data has not proved practical without automation. We present an automated method to quantitatively evaluate airway lumen diameter, wall thickness and broncho-arterial ratios. In addition, our method provides 3D visualization of these values, graphically illustrating the location and extent of disease. Our algorithm begins by automatic airway segmentation to extract paths to the distal airways, and to create a map of airway diameters. Normally, airway diameters decrease as paths progress distally; failure to taper indicates abnormal dilatation. Our approach monitors airway lumen diameters along each airway path in order to detect abnormal profiles, allowing even subtle degrees of pathologic dilatation to be identified. Our method also systematically computes the broncho-arterial ratio at every terminal branch of the tree model, as a ratio above 1 indicates potentially abnormal bronchial dilatation. Finally, the airway wall thickness is computed at corresponding locations. These measurements are used to highlight abnormal branches for closer inspection, and can be summed to compute a quantitative global score for the entire airway tree, allowing reproducible longitudinal assessment of disease severity. Preliminary tests on patients diagnosed with bronchiectasis demonstrated rapid identification of lack of tapering, which also was confirmed by corresponding demonstration of elevated broncho-arterial ratios.

  12. Trajectory-based morphological operators: a model for efficient image processing.

    PubMed

    Jimeno-Morenilla, Antonio; Pujol, Francisco A; Molina-Carmona, Rafael; Sánchez-Romero, José L; Pujol, Mar

    2014-01-01

    Mathematical morphology has been an area of intensive research over the last few years. Although many remarkable advances have been achieved throughout these years, there is still a great interest in accelerating morphological operations in order for them to be implemented in real-time systems. In this work, we present a new model for computing mathematical morphology operations, the so-called morphological trajectory model (MTM), in which a morphological filter will be divided into a sequence of basic operations. Then, a trajectory-based morphological operation (such as dilation, and erosion) is defined as the set of points resulting from the ordered application of the instant basic operations. The MTM approach allows working with different structuring elements, such as disks, and from the experiments, it can be extracted that our method is independent of the structuring element size and can be easily applied to industrial systems and high-resolution images.

  13. High-order rogue wave solutions of the classical massive Thirring model equations

    NASA Astrophysics Data System (ADS)

    Guo, Lijuan; Wang, Lihong; Cheng, Yi; He, Jingsong

    2017-11-01

    The nth-order solutions of the classical massive Thirring model (MTM) equations are derived by using the n-fold Darboux transformation. These solutions are expressed by the ratios of the two determinants consisted of 2n eigenfunctions under the reduction conditions. Using this method, rogue waves are constructed explicitly up to the third-order. Three patterns, i.e., fundamental, triangular and circular patterns, of the rogue waves are discussed. The parameter μ in the MTM model plays the role of the mass in the relativistic field theory while in optics it is related to the medium periodic constant, which also results in a significant rotation and a remarkable lengthening of the first-order rogue wave. These results provide new opportunities to observe rouge waves by using a combination of electromagnetically induced transparency and the Bragg scattering four-wave mixing because of large amplitudes.

  14. Development of an instrumentation system for measurement of degradation of lubricating oil using optical fiber sensor

    NASA Astrophysics Data System (ADS)

    Laskar, S.; Bordoloi, S.

    2016-01-01

    This paper presents an instrumentation system to measure the degradation in lubricating oil using a bare, tapered and bent multi-mode optical fiber (BTBMOF) sensor probe and a temperature probe. The sensor system consists of (i) a bare, tapered and bent multi-mode optical fiber (BTBMOF) as optical sensor along with a laser source and a LDR (Light Dependent Resistor) as detector (ii) a temperature sensor (iii) a ATmega microcontroller based data acquisition system and (iv) a trained ANN for processing and calibration. The BTBMOF sensor and the temperature sensor are used to provide the measure of refractive index (RI) and the temperature of a lubricating oil sample. A microcontroller based instrumentation system with trained ANN algorithm has been developed to determine the degradation of the lubricating oil sample by sampling the readings of the optical fiber sensor, and the temperature sensor.

  15. Pressure generation to 65 GPa in a Kawai-type multi-anvil apparatus with tungsten carbide anvils

    NASA Astrophysics Data System (ADS)

    Ishii, Takayuki; Yamazaki, Daisuke; Tsujino, Noriyoshi; Xu, Fang; Liu, Zhaodong; Kawazoe, Takaaki; Yamamoto, Takafumi; Druzhbin, Dmitry; Wang, Lin; Higo, Yuji; Tange, Yoshinori; Yoshino, Takashi; Katsura, Tomoo

    2017-10-01

    We have expanded the pressure ranges at room and high temperatures generated in a Kawai-type multi-anvil apparatus (KMA) using tungsten carbide (WC) anvils with a high hardness of Hv = 2700 and a Young's modulus of 660 GPa. At room temperature, a pressure of 64 GPa, which is the highest pressure generated with KMA using WC anvils in the world, was achieved using 1°-tapered anvils with a 1.5-mm truncation. Pressures of 48-50 GPa were generated at high temperatures of 1600-2000 K, which are also higher than previously achieved. Tapered anvils make wide anvil gaps enabling efficient X-ray diffraction. The present pressure generation technique can be used for studying the upper part of the Earth's lower mantle down to 1200 km depth without sintered diamond anvils.

  16. All-fiber orbital angular momentum mode generation and transmission system

    NASA Astrophysics Data System (ADS)

    Heng, Xiaobo; Gan, Jiulin; Zhang, Zhishen; Qian, Qi; Xu, Shanhui; Yang, Zhongmin

    2017-11-01

    We proposed and demonstrated an all-fiber system for generating and transmitting orbital angular momentum (OAM) mode light. A specially designed multi-core fiber (MCF) was used to endow with guide modes different phase change and two tapered transition regions were used for providing low-loss interfaces between different fiber structures. By arranging the refractive index distribution among the multi-cores and controlling the length of MCF, which essentially change the phase difference between the neighboring cores, OAM modes with different topological charge l can be generated selectively. Through two tapered transition regions, the non-OAM mode light can be effectively injected into the MCF and the generated OAM mode light can be easily launched into OAM mode supporting fiber for long distance and high purity transmission. Such an all-fiber OAM mode generation and transmission system owns the merits of flexibility, compactness, portability, and would have practical application value in OAM optical fiber communication systems.

  17. Rock Magnetic Fabrics, Paleomagnetic Vectors, and Rock Magnetic Cyclostratigraphy of the Marcellus FM, Sunbury PA

    NASA Astrophysics Data System (ADS)

    Minguez, D. A.; Kodama, K. P.

    2013-12-01

    We present the preliminary results of a multi-faceted rock magnetic study conducted on 195 samples from the Oatka Creek member of the Marcellus formation, where it has been extracted from the subsurface as a drill core near Sunbury, PA. Samples were oriented based on bedding attitude observed within the core and were removed from the core at a spacing of ≈0.25 meters starting from the base (depth ≈ 500 meters) and spanning 51 meters of stratigraphic section. The results of measurements of the anisotropy of magnetic susceptibility (AMS) consistently demonstrate a nearly triaxial fabric with maximum principal axes clustering east-west and horizontal in geographic coordinates, nearly parallel to the direction of bedding strike. AMS minimum principal axes cluster near the pole to the bedding plane. Anisotropy of anhysteretic remanence (AAR) applied with a 100 mT peak field and a 97 μT bias field in 9 orientations demonstrates a markedly different fabric, with maximum principal axis clustering north-south and horizontal in geographic coordinates. Minimum principal axes of AAR cluster steeply (~60-70 degrees) to the west. The discrepancy between AAR and AMS fabrics likely indicates the AMS is dominated by paramagnetic clays, and thus may be interpreted as an east-west intersection lineation of clay particles dipping gently north or south. Paleomagnetic directions obtained using Alternating Field (AF) demagnetization in 5 mT steps up to 110 mT demonstrates a high coercivity remanence (>35 mT) with a south and shallow direction (D= 183.4 I=-14.7). This result is consistent with previous studies of the Marcellus formation and the Devonian Catskill red beds. Thermal demagnetization experiments demonstrate a similar magnetization removed by temperatures between 250 and 350 degrees Celsius, however, continued heating results in the acquisition of strong, inconsistent magnetizations likely the result of oxidizing iron sulfides. Thermal demagnetization of orthogonal partial ARMs applied in 100 mT and 50 mT peak fields was conducted on a subset of samples sealed in aluminum foil with alumina-silica cement to prevent oxidization. The results demonstrate that the low coercivity pARM is removed by 400 degrees Celsius and the high coercivity pARM, which is only 10% of the total remanence, is removed by 600 degrees Celsius. The results suggest the presence of low coercivity Fe sulfides and high coercivity magnetite. Lastly, time series analysis of bulk magnetic susceptibility using the Multi-Taper Method (MTM) demonstrates oscillations with a wavelength of 18 meters above the 99% confidence level with respect to the robust red noise. This wavelength may have a duration of 405 kyr given ancillary chronostratigraphic evidence.

  18. Tapered slot antenna design for vehicular GPR applications

    NASA Astrophysics Data System (ADS)

    Bıçak, Emrullah; Yeǧin, Korkut; Nazlı, Hakki; Daǧ, Mahmut

    2014-05-01

    Vehicular applications of UWB GPR demand multiple GPR sensors operating in a harsh environment. One of the key elements of in the sensor is its UWB antenna which has minimal inter-element coupling, low group delay, high directivity and less prone to environmental conditions. Tapered slot antennas (TSA's) provide good impedance match, but they need to be modified for above specifications. Parasitic slot loaded TSA with balanced feed is proposed and a multi-channel antenna array structure is formed. Structural parameters are numerically analyzed and a prototype is built. Measurements show good performance for UWB GPR applications.

  19. Design, Fabrication and Testing of Two Dimensional Radio-Frequency Metamaterials

    DTIC Science & Technology

    2014-03-03

    metasurfaces . These antennas are either MTM based or utilize MTMs to increase performance. The benefits of these antennas are: reduced size, lower...reduced size and increased quality factor. Finally, the antennas loaded with metasurfaces are similar to the MTM loading; in the fact that the... metasurface enhances the antenna performance instead of performing the antenna function. This type of antenna has shown increased directionality and

  20. 76 FR 28452 - Notice of Proposed Reinstatement of Terminated Oil and Gas Leases MTM 99624 and MTM 99625

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-17

    ... lease terms for rentals and royalties of $10 per acre and 16\\2/3\\ percent. The lessee paid the $500 administration fee for the reinstatement of each lease and $163 cost for publishing this Notice. The lessee met... increased royalty of 16\\2/3\\ percent; and The $163 cost of publishing this Notice. FOR FURTHER INFORMATION...

  1. 76 FR 28452 - Notice of Proposed Reinstatement of Terminated Oil and Gas Lease MTM 94684 and MTM 94685

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-17

    ... agrees to new lease terms for rentals and royalties of $10 per acre and 16\\2/3\\ percent. The lessee paid the $500 administration fee for the reinstatement of each lease and $163 cost for publishing this... $10 per acre; The increased royalty of 16\\2/3\\ percent; and The $163 cost of publishing this Notice...

  2. Deconstructing the deconstruction of Appalachia: Mountaintop mining effects on hydrology across temporal and spatial scales

    NASA Astrophysics Data System (ADS)

    Nippgen, F.; Ross, M. R. V.; Bernhardt, E. S.; McGlynn, B. L.

    2017-12-01

    Mountaintop mining (MTM) is an especially destructive form of surface coal mining. It is widespread in Central Appalachia and is practiced around the world. In the process of accessing coal seams up to several hundred meters below the surface, mountaintops and ridges are removed via explosives and heavy machinery with the resulting overburden pushed into nearby valleys. This broken up rock and soil material represents a largely unknown amount of storage for incoming precipitation that facilitates enhanced chemical weathering rates and increased dissolved solids exports to streams. However, assessing the independent impact of MTM can be difficult in the presence of other forms of mining, especially underground mining. Here, we evaluate the effect of MTM on water quantity and quality on annual, seasonal, and event time scales in two sets of paired watersheds in southwestern West Virginia impacted by MTM. On an annual timescale, the mined watersheds sustained baseflow throughout the year, while the first order watersheds ceased flowing during the latter parts of the growing season. In fractionally mined watersheds that continued to flow, the water in the stream was exclusively generated from mined portions of the watersheds, leading to elevated total dissolved solids in the stream water. On the event time scale, we analyzed 50 storm events over a water year for a range of hydrologic response metrics. The mined watersheds exhibited smaller runoff ratios and longer response times during the wet dormant season, but responded similarly to rainfall events during the growing season or even exceeded the runoff magnitude of the reference watersheds. Our research demonstrates a clear difference in hydrologic response between mined and unmined watersheds during the growing season and the dormant season that are detectable at annual, seasonal, and event time scales. For larger spatial scales (up to 2,000km2) the effect of MTM on water quantity is not as easily detectable. At these larger scales, other land uses can mask possible alterations in hydrology or the percentage of MTM disturbed areas becomes negligible.

  3. Small-for-gestational age prevalence risk factors in central Appalachian states with mountain-top mining.

    PubMed

    Ferdosi, Hamid; Lamm, Steve H; Afari-Dwamena, Nana Ama; Dissen, Elisabeth; Chen, Rusan; Li, Ji; Feinleib, Manning

    2018-01-01

    To identify risk factors for small-for-gestational age (SGA) for counties in central Appalachian states (Kentucky (KY), Tennessee (TN), Virginia (VA), and West Virginia (WV)) with varied coal mining activities. Live birth certificate files (1990-2002) were used for obtaining SGA prevalence rates for mothers based on the coal mining activities of their counties of residence, mountain-top mining (MTM) activities, underground mining activities but no mountain-top mining activity (non-MTM), or having no mining activities (non-mining). Co-variable information, including maternal tobacco use, was also obtained from the live birth certificate. Adjusted odds ratios were obtained using multivariable logistic regression comparing SGA prevalence rates for counties with coal mining activities to those without coal mining activities and comparing SGA prevalence rates for counties with coal mining activities for those with and without mountain-top mining activities. Comparisons were also made among those who had reported tobacco use and those who had not. Both tobacco use prevalence and SGA prevalence were significantly greater for mining counties than for non-mining counties and for MTM counties than for non-MTM counties. Adjustment for tobacco use alone explained 50% of the increased SGA risk for mining counties and 75% of the risk for MTM counties, including demographic pre-natal care co-variables that explained 75% of the increased SGA risk for mining counties and 100% of the risk for MTM. The increased risk of SGA was limited to the third trimester births among tobacco users and independent of the mining activities of their counties of residence. This study demonstrates that the increased prevalence of SGA among residents of counties with mining activity was primarily explained by the differences in maternal tobacco use prevalence, an effect that itself was gestational-age dependent. Self-reported tobacco use marked the population at the increased risk for SGA in central Appalachian states. Int J Occup Med Environ Health 2018;31(1):11-23. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  4. Modeling and simulation performance of sucker rod beam pump

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aditsania, Annisa, E-mail: annisaaditsania@gmail.com; Rahmawati, Silvy Dewi, E-mail: silvyarahmawati@gmail.com; Sukarno, Pudjo, E-mail: psukarno@gmail.com

    2015-09-30

    Artificial lift is a mechanism to lift hydrocarbon, generally petroleum, from a well to surface. This is used in the case that the natural pressure from the reservoir has significantly decreased. Sucker rod beam pumping is a method of artificial lift. Sucker rod beam pump is modeled in this research as a function of geometry of the surface part, the size of sucker rod string, and fluid properties. Besides its length, sucker rod string also classified into tapered and un-tapered. At the beginning of this research, for easy modeling, the sucker rod string was assumed as un-tapered. The assumption provedmore » non-realistic to use. Therefore, the tapered sucker rod string modeling needs building. The numerical solution of this sucker rod beam pump model is computed using finite difference method. The numerical result shows that the peak of polished rod load for sucker rod beam pump unit C-456-D-256-120, for non-tapered sucker rod string is 38504.2 lb, while for tapered rod string is 25723.3 lb. For that reason, to avoid the sucker rod string breaks due to the overload, the use of tapered sucker rod beam string is suggested in this research.« less

  5. Volatility and change in chronic pain severity predict outcomes of treatment for prescription opioid addiction.

    PubMed

    Worley, Matthew J; Heinzerling, Keith G; Shoptaw, Steven; Ling, Walter

    2017-07-01

    Buprenorphine-naloxone (BUP-NLX) can be used to manage prescription opioid addiction among persons with chronic pain, but post-treatment relapse is common and difficult to predict. This study estimated whether changes in pain over time and pain volatility during BUP-NLX maintenance would predict opioid use during the taper BUP-NLX taper. Secondary analysis of a multi-site clinical trial for prescription opioid addiction, using data obtained during a 12-week BUP-NLX stabilization and 4-week BUP-NLX taper. Community clinics affiliated with a national clinical trials network in 10 US cities. Subjects with chronic pain who entered the BUP-NLX taper phase (n = 125) with enrollment occurring from June 2006 to July 2009 (52% male, 88% Caucasian, 31% married). Outcomes were weekly biologically verified and self-reported opioid use from the 4-week taper phase. Predictors were estimates of baseline severity, rate of change and volatility in pain from weekly self-reports during the 12-week maintenance phase. Controlling for baseline pain and treatment condition, increased pain [odds ratio (OR) = 2.38, P = 0.02] and greater pain volatility (OR = 2.43, P = 0.04) predicted greater odds of positive opioid urine screen during BUP-NLX taper. Increased pain (IRR = 1.40, P = 0.04) and greater pain volatility [incidence-rate ratio (IRR) = 1.66, P = 0.009] also predicted greater frequency of self-reported opioid use. Adults with chronic pain receiving out-patient treatment with buprenorphine-naloxone (BUP-NLX) for prescription opioid addiction have an elevated risk for opioid use when tapering off maintenance treatment. Those with relative persistence in pain over time and greater volatility in pain during treatment are less likely to sustain abstinence during BUP-NLX taper. © 2017 Society for the Study of Addiction.

  6. Temporal changes in taxonomic and functional diversity of fish assemblages downstream from mountaintop mining

    USGS Publications Warehouse

    Hitt, Nathaniel P.; Chambers, Douglas B.

    2014-01-01

    Mountaintop mining (MTM) affects chemical, physical, and hydrological properties of receiving streams, but the long-term consequences for fish-assemblage structure and function are poorly understood. We sampled stream fish assemblages using electrofishing techniques in MTM exposure sites and reference sites within the Guyandotte River basin, USA, during 2010–2011. We calculated indices of taxonomic diversity (species richness, abundance, Shannon diversity) and functional diversity (functional richness, functional evenness, functional divergence) to compare exposure and reference assemblages between seasons (spring and autumn) and across years (1999–2011). We based temporal comparisons on 2 sites that were sampled during 1999–2001 by Stauffer and Ferreri (2002). Exposure assemblages had lower taxonomic and functional diversity than reference assemblages or simulated assemblages that accounted for random variation. Differences in taxonomic composition between reference and exposure assemblages were associated with conductivity and aqueous Se concentrations. Exposure assemblages had fewer species, lower abundances, and less biomass than reference assemblages across years and seasons. Green Sunfish (Lepomis cyanellus) and Creek Chub (Semotilus atromaculatus) became numerically dominant in exposure assemblages over time because of their persistence and losses of other taxa. In contrast, species richness increased over time in reference assemblages, a result that may indicate recovery from drought. Mean individual biomass increased as fish density decreased and most obligate invertivores were apparently extirpated at MTM exposure sites. Effects of MTM were not related to physical-habitat conditions but were associated with water-quality variables, which may limit quality and availability of benthic macroinvertebrate prey. Simulations revealed effects of MTM that could not be attributed to random variation in fish assemblage structure.

  7. The Professional Culture of Community Pharmacy and the Provision of MTM Services.

    PubMed

    Rosenthal, Meagen M; Holmes, Erin R

    2018-03-21

    The integration of advanced pharmacy services into community pharmacy practice is not complete. According to implementation research understanding professional culture, as a part of context, may provide insights for accelerating this process. There are three objectives in this study. The first objective of this study was to validate an adapted version of an organizational culture measure in a sample of United States' (US) community pharmacists. The second objective was to examine potential relationships between the cultural factors identified using the validated instrument and a number of socialization and education variables. The third objective was to examine any relationships between the scores on the identified cultural factors and the provision of MTM services. This study was a cross-sectional online survey for community pharmacists in the southeastern US. The survey contained questions on socialization/education, respondents' self-reported provision of medication therapy management (MTM) services, and the organizational culture profile (OCP). Analyses included descriptive statistics, a principle components analysis (PCA), independent samples t-test, and multivariate ordinal regression. A total of 303 surveys were completed. The PCA revealed a six-factor structure: social responsibility, innovation, people orientation, competitiveness, attention to detail, and reward orientation. Further analysis revealed significant relationships between social responsibility and years in practice, and people orientation and attention to detail and pharmacists' training and practice setting. Significant positive relationships were observed between social responsibility, innovation, and competitiveness and the increased provision of MTM services. The significant relationships identified between the OCP factors and community pharmacist respondents' provision of MTM services provides an important starting point for developing interventions to improve the uptake of practice change opportunities.

  8. Nonlinear surface waves at ferrite-metamaterial waveguide structure

    NASA Astrophysics Data System (ADS)

    Hissi, Nour El Houda; Mokhtari, Bouchra; Eddeqaqi, Noureddine Cherkaoui; Shabat, Mohammed Musa; Atangana, Jacques

    2016-09-01

    A new ferrite slab made of a metamaterial (MTM), surrounded by a nonlinear cover cladding and a ferrite substrate, was shown to support unusual types of electromagnetic surface waves. We impose the boundary conditions to derive the dispersion relation and others necessary to formulate the proposed structure. We analyse the dispersion properties of the nonlinear surface waves and we calculate the associated propagation index and the film-cover interface nonlinearity. In the calculation, several sets of the permeability of the MTM are considered. Results show that the waves behaviour depends on the values of the permeability of the MTM, the thickness of the waveguide and the film-cover interface nonlinearity. It is also shown that the use of the singular solutions to the electric field equation allows to identify several new properties of surface waves which do not exist in conventional waveguide.

  9. Modeling the microstructurally dependent mechanical properties of poly(ester-urethane-urea)s.

    PubMed

    Warren, P Daniel; Sycks, Dalton G; McGrath, Dominic V; Vande Geest, Jonathan P

    2013-12-01

    Poly(ester-urethane-urea) (PEUU) is one of many synthetic biodegradable elastomers under scrutiny for biomedical and soft tissue applications. The goal of this study was to investigate the effect of the experimental parameters on mechanical properties of PEUUs following exposure to different degrading environments, similar to that of the human body, using linear regression, producing one predictive model. The model utilizes two independent variables of poly(caprolactone) (PCL) type and copolymer crystallinity to predict the dependent variable of maximum tangential modulus (MTM). Results indicate that comparisons between PCLs at different degradation states are statistically different (p < 0.0003), while the difference between experimental and predicted average MTM is statistically negligible (p < 0.02). The linear correlation between experimental and predicted MTM values is R(2) = 0.75. Copyright © 2013 Wiley Periodicals, Inc., a Wiley Company.

  10. Transverse Vibration of Tapered Single-Walled Carbon Nanotubes Embedded in Viscoelastic Medium

    NASA Astrophysics Data System (ADS)

    Lei, Y. J.; Zhang, D. P.; Shen, Z. B.

    2017-12-01

    Based on the nonlocal theory, Euler-Bernoulli beam theory and Kelvin viscoelastic foundation model, free transverse vibration is studied for a tapered viscoelastic single-walled carbon nanotube (visco-SWCNT) embedded in a viscoelastic medium. Firstly, the governing equations for vibration analysis are established. And then, we derive the natural frequencies in closed form for SWCNTs with arbitrary boundary conditions by applying transfer function method and perturbation method. Numerical results are also presented to discuss the effects of nonlocal parameter, relaxation time and taper parameter of SWCNTs, and material property parameters of the medium. This study demonstrates that the proposed model is available for vibration analysis of the tapered SWCNTs-viscoelastic medium coupling system.

  11. Effect of ripple taper on band-gap overlap in a coaxial Bragg structure operating at terahertz frequency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ding Xueyong; Li Hongfan; Lv Zhensu

    Based on the mode-coupling method, numerical analysis is presented to demonstrate the influence of ripple taper on band-gap overlap in a coaxial Bragg structure operating at terahertz frequency. Results show that the interval between the band-gaps of the competing mode and the desired working mode is narrowed by use of positive-taper ripples, but is expanded if negative-taper ripples are employed, and the influence of the negative-taper ripples is obviously more advantageous than the positive-taper ripples; the band-gap overlap of modes can be efficiently separated by use of negative-taper ripples. The residual side-lobes of the frequency response in a coaxial Braggmore » structure with ripple taper also can be effectively suppressed by employing the windowing-function technique. These peculiarities provide potential advantage in constructing a coaxial Bragg cavity with high quality factor for single higher-order-mode operation of a high-power free-electron maser in the terahertz frequency range.« less

  12. Manufacturing Work Measurement System Evaluation. Reference Guide

    DTIC Science & Technology

    1987-04-01

    discussions with users of the MTM-MEK predetermined time system. The coranents listed below are based on these discussions and, while a broad range...discussions with users of the MTM-V predeterroined time system. The coranents listed below are based on these discussions and, while a broad range of...industries were sampled, coranents should not be considered universal and therefore may not be applicable to all manufacturing environments: 0 Easy to

  13. A Multiscale Material Testing System for In Situ Optical and Electron Microscopes and Its Application

    PubMed Central

    Ye, Xuan; Cui, Zhiguo; Fang, Huajun; Li, Xide

    2017-01-01

    We report a novel material testing system (MTS) that uses hierarchical designs for in-situ mechanical characterization of multiscale materials. This MTS is adaptable for use in optical microscopes (OMs) and scanning electron microscopes (SEMs). The system consists of a microscale material testing module (m-MTM) and a nanoscale material testing module (n-MTM). The MTS can measure mechanical properties of materials with characteristic lengths ranging from millimeters to tens of nanometers, while load capacity can vary from several hundred micronewtons to several nanonewtons. The m-MTM is integrated using piezoelectric motors and piezoelectric stacks/tubes to form coarse and fine testing modules, with specimen length from millimeters to several micrometers, and displacement distances of 12 mm with 0.2 µm resolution for coarse level and 8 µm with 1 nm resolution for fine level. The n-MTM is fabricated using microelectromechanical system technology to form active and passive components and realizes material testing for specimen lengths ranging from several hundred micrometers to tens of nanometers. The system’s capabilities are demonstrated by in-situ OM and SEM testing of the system’s performance and mechanical properties measurements of carbon fibers and metallic microwires. In-situ multiscale deformation tests of Bacillus subtilis filaments are also presented. PMID:28777341

  14. Methods Engineering Workshop for the Shipbuilding Industry

    DTIC Science & Technology

    1985-09-01

    physiological process that reduces the performance capacity and motivation of humans sub- jected to excessive or repeated work stresses. fatigue allowance, Time...often involves basic business fundamentals, motivation , common sense, and the plain hard work of one person doing something. But the accomplishment that...utilize a batch mode form. ” (3) SERGE A. BIRN HAS A TRAINING SCHOOL IN CINCINNATI FOR MTM, MSD, MCD, MOTIVATION -PRODUCTIVITY , TIME STUDY, METHODS

  15. Assembling Precise Truss Structures With Minimal Stresses

    NASA Technical Reports Server (NTRS)

    Sword, Lee F.

    1996-01-01

    Improved method of assembling precise truss structures involves use of simple devices. Tapered pins that fit in tapered holes indicate deviations from prescribed lengths. Method both helps to ensure precision of finished structures and minimizes residual stresses within structures.

  16. Mid-infrared supercontinuum generation spanning from 1.9 to 5.7 μm in a chalcogenide fiber taper with ultra-high NA

    NASA Astrophysics Data System (ADS)

    Wang, Yingying; Dai, Shixun; Peng, Xuefeng; Zhang, Peiqing; Wang, Xunsi; You, Chenyang

    2018-01-01

    We report a broadband supercontinuum generation in a chalcogenide fiber taper with an ultra-high numerical aperture. The chalcogenide step-index fiber consisting of As2Se3 core and As2S3 cladding was fabricated by using the isolated stacked extrusion method. The fiber taper with a core diameter of 1.75 μm was prepared by employing a homemade tapering setup. By pumping the fiber taper with a femtosecond laser pulses at 3.3 μm, a broadband supercontinuum generation spanning from 1.9 to 5.7 μm was achieved.

  17. Ultra-low-loss tapered optical fibers with minimal lengths

    NASA Astrophysics Data System (ADS)

    Nagai, Ryutaro; Aoki, Takao

    2014-11-01

    We design and fabricate ultra-low-loss tapered optical fibers (TOFs) with minimal lengths. We first optimize variations of the torch scan length using the flame-brush method for fabricating TOFs with taper angles that satisfy the adiabaticity criteria. We accordingly fabricate TOFs with optimal shapes and compare their transmission to TOFs with a constant taper angle and TOFs with an exponential shape. The highest transmission measured for TOFs with an optimal shape is in excess of 99.7 % with a total TOF length of only 23 mm, whereas TOFs with a constant taper angle of 2 mrad reach 99.6 % transmission for a 63 mm TOF length.

  18. Studies of geometrical profiling in fabricated tapered optical fibers using whispering gallery modes spectroscopy

    NASA Astrophysics Data System (ADS)

    Kavungal, Vishnu; Farrell, Gerald; Wu, Qiang; Kumar Mallik, Arun; Semenova, Yuliya

    2018-03-01

    This paper experimentally demonstrates a method for geometrical profiling of asymmetries in fabricated thin microfiber tapers with waist diameters ranging from ∼10 to ∼50 μm with submicron accuracy. The method is based on the analysis of whispering gallery mode resonances excited in cylindrical fiber resonators as a result of evanescent coupling of light propagating through the fiber taper. The submicron accuracy of the proposed method has been verified by SEM studies. The method can be applied as a quality control tool in fabrication of microfiber based devices and sensors or for fine-tuning of microfiber fabrication set-ups.

  19. Supercontinuum generation from 437 to 2850 nm in a tapered fluorotellurite microstructured fiber

    NASA Astrophysics Data System (ADS)

    Wang, F.; Jia, Z. X.; Yao, C. F.; Wang, S. B.; Hu, M. L.; Wu, C. F.; Ohishi, Y.; Qin, W. P.; Qin, G. S.

    2016-12-01

    We demonstrated supercontinuum (SC) generation in a tapered fluorotellurite microstructured fiber (MF) with a sub-micrometer core diameter. Fluorotellurite MFs based on TeO2-BaF2-Y2O3 glasses were fabricated by using a rod-in-tube method and a tapered fluorotellurite MF with a minimum core diameter of ~0.65 µm was prepared by employing a tapering system. A 1560 nm femtosecond fiber laser was used as the pumping source. With increasing the peak power of the launched pump laser to ~11 kW, SC light expanding from 437 to 2850 nm was generated in the tapered fluorotellurite MF. In addition, relatively strong blue-shifted dispersive wave at ~489 nm was also observed from the tapered fluorotellurite MF.

  20. [Better multidisciplinary team meetings are linked to better care].

    PubMed

    van Drielen, Eveline; de Vries, Antoinette W; Ottevanger, P B Nelleke; Hermens, Rosella P M G

    2012-01-01

    Discussing a patient in an oncology multidisciplinary team meeting (MTM) increases the value of the quality of the treatment chosen. MTMs are increasingly mentioned in guidelines and indicator sets. Based on literature review and observations, the Comprehensive Cancer Centre Netherlands (CCCNL), in collaboration with IQ Healthcare and the Department of Medical Oncology of the UMC St Radboud Nijmegen in the Netherlands, has conducted research into the quality criteria for a good MTM. Two of our studies show that the organisation of MTMs can be significantly improved. Based on the results, we developed a checklist to accomplish this. The most significant areas of improvement for optimising the organisation of MTMs are: (a) the presence of specialists from all relevant disciplines; (b) a capable chairman who promotes the efficiency of the MTM; and (c) the reduction of intruding factors, such as mobile phones and participants who walk in and out.

  1. Impact of an Elective Course on Pharmacy Students’ Attitudes, Beliefs, and Competency Regarding Medicare Part D

    PubMed Central

    Patel, Rajul A.; Thai, Huong K.; Phou, Christine M.; Walberg, Mark P.; Woelfel, Joseph A.; Carr-Lopez, Sian M.; Chan, Emily K.

    2012-01-01

    Objective. To determine the impact of an elective course on pharmacy students’ perceptions, knowledge, and confidence regarding Medicare Part D, medication therapy management (MTM), and immunizations. Design. Thirty-three pharmacy students were enrolled in a Medicare Part D elective course that included both classroom instruction and experiential training. Assessment. Students’ self-reported confidence in and knowledge of Part D significantly improved upon course completion. End-of-course student perceptions about the relative importance of various aspects of MTM interventions and their confidence in performing MTM services significantly improved from those at the beginning of the course. Students’ confidence in performing immunizations also increased significantly from the start of the course. Conclusion. A classroom course covering Medicare Part D with an experiential requirement serving beneficiaries can improve students’ attitudes and knowledge about Medicare Part D and their confidence in providing related services to beneficiaries in the community. PMID:22761532

  2. Methylation of arsenic by recombinant human wild-type arsenic (+ 3 oxidation state) methyltransferase and its methionine 287 threonine (M287T) polymorph: Role of glutathione

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ding, Lan; Saunders, R. Jesse; Drobná, Zuzana

    2012-10-01

    Arsenic (+ 3 oxidation state) methyltransferase (AS3MT) is the key enzyme in the pathway for methylation of arsenicals. A common polymorphism in the AS3MT gene that replaces a threonyl residue in position 287 with a methionyl residue (AS3MT/M287T) occurs at a frequency of about 10% among populations worldwide. Here, we compared catalytic properties of recombinant human wild-type (wt) AS3MT and AS3MT/M287T in reaction mixtures containing S-adenosylmethionine, arsenite (iAs{sup III}) or methylarsonous acid (MAs{sup III}) as substrates and endogenous or synthetic reductants, including glutathione (GSH), a thioredoxin reductase (TR)/thioredoxin (Trx)/NADPH reducing system, or tris (2-carboxyethyl) phosphine hydrochloride (TCEP). With either TR/Trx/NADPHmore » or TCEP, wtAS3MT or AS3MT/M287T catalyzed conversion of iAs{sup III} to MAs{sup III}, methylarsonic acid (MAs{sup V}), dimethylarsinous acid (DMAs{sup III}), and dimethylarsinic acid (DMAs{sup V}); MAs{sup III} was converted to DMAs{sup III} and DMAs{sup V}. Although neither enzyme required GSH to support methylation of iAs{sup III} or MAs{sup III}, addition of 1 mM GSH decreased K{sub m} and increased V{sub max} estimates for either substrate in reaction mixtures containing TR/Trx/NADPH. Without GSH, V{sub max} and K{sub m} values were significantly lower for AS3MT/M287T than for wtAS3MT. In the presence of 1 mM GSH, significantly more DMAs{sup III} was produced from iAs{sup III} in reactions catalyzed by the M287T variant than in wtAS3MT-catalyzed reactions. Thus, 1 mM GSH modulates AS3MT activity, increasing both methylation rates and yield of DMAs{sup III}. AS3MT genotype exemplified by differences in regulation of wtAS3MT and AS3MT/M287T-catalyzed reactions by GSH may contribute to differences in the phenotype for arsenic methylation and, ultimately, to differences in the disease susceptibility in individuals chronically exposed to inorganic arsenic. -- Highlights: ► Human AS3MT and AS3MT(M287T) require a dithiol reductant for optimal activity. ► Both enzymes methylate arsenite to tri- and pentavalent methylated metabolites. ► Neither enzyme requires glutathione (GSH) to methylate arsenite or methylarsonite. ► However, in presence of a dithiol addition of 1 mM GSH increases methylation rates. ► In presence of 1 mM GSH, AS3MT(M287T) produces more dimethylarsinite than AS3MT.« less

  3. Study of nonlinear liquid effects into ytterbium-doped fiber laser for multi-wavelength generation

    NASA Astrophysics Data System (ADS)

    Lozano-Hernandez, T.; Jauregui-Vazquez, D.; Estudillo-Ayala, J.; Herrera-Piad, L. A.; Rojas-Laguna, R.; Hernandez-Garcia, J. M.; Sierra-Hernandez, J. M.

    2018-02-01

    We present an experimental study of liquid refractive index effects into Ytterbium ring fiber laser cavity configuration. The laser is operated using a bi-tapered optical fiber immersed in water-alcohol concentrations. When the tapered fiber is dipped into a distilled water, a single lasing line with a peak power centered at 1025 nm is achieved. Afterward, by changing the polarization state into the cavity the lasing line can be switched. Moreover, by modifying the refractive index liquid surrounding media the lasing lines can be controlled and special liquid provide nonlinear response. The laser offers compactness, low effective cost and good stability.

  4. Comparison of Pressure Changes by Head and Neck Position between High-Volume Low-Pressure and Taper-Shaped Cuffs: A Randomized Controlled Trial

    PubMed Central

    Komasawa, Nobuyasu; Mihara, Ryosuke; Imagawa, Kentaro; Hattori, Kazuo; Minami, Toshiaki

    2015-01-01

    The present study compared changes in cuff pressure by head and neck position between high-volume low-pressure (HVLP) and taper-shaped (taper) cuffs in a prospective randomized clinical trial. Methods. Forty patients were intubated using tracheal tubes with either HVLP (n = 20; HVLP group) or taper-shaped (n = 20; Taper group) cuffs. Initial cuff pressure was adjusted to 15, 20, or 25 cmH2O in the neutral position. Cuff pressure was evaluated after changing the head and neck positions to flexion, extension, and rotation. Results. Cuff pressure significantly increased with flexion in both HVLP and Taper groups at all initial cuff pressures. It significantly increased with extension in the HVLP group, but not in the Taper group. Cuff pressure did not significantly differ with rotation in either group and was significantly smaller in the Taper group during flexion and extension than in the HVLP group, regardless of initial cuff pressure. Conclusion. Cuff pressure changes with head and neck flexion and extension were smaller in the Taper group than in the HVLP group. Our results highlight the potential for taper cuffs to prevent excessive cuff pressure increases with positional changes in the head and neck. This trial is registered with UMIN000016119. PMID:26509152

  5. In-situ Tapering of Chalcogenide Fiber for Mid-infrared Supercontinuum Generation

    PubMed Central

    Rudy, Charles W.; Marandi, Alireza; Vodopyanov, Konstantin L.; Byer, Robert L.

    2013-01-01

    Supercontinuum generation (SCG) in a tapered chalcogenide fiber is desirable for broadening mid-infrared (or mid-IR, roughly the 2-20 μm wavelength range) frequency combs1, 2 for applications such as molecular fingerprinting, 3 trace gas detection, 4 laser-driven particle acceleration, 5 and x-ray production via high harmonic generation. 6 Achieving efficient SCG in a tapered optical fiber requires precise control of the group velocity dispersion (GVD) and the temporal properties of the optical pulses at the beginning of the fiber, 7 which depend strongly on the geometry of the taper. 8 Due to variations in the tapering setup and procedure for successive SCG experiments-such as fiber length, tapering environment temperature, or power coupled into the fiber, in-situ spectral monitoring of the SCG is necessary to optimize the output spectrum for a single experiment. In-situ fiber tapering for SCG consists of coupling the pump source through the fiber to be tapered to a spectral measurement device. The fiber is then tapered while the spectral measurement signal is observed in real-time. When the signal reaches its peak, the tapering is stopped. The in-situ tapering procedure allows for generation of a stable, octave-spanning, mid-IR frequency comb from the sub harmonic of a commercially available near-IR frequency comb. 9 This method lowers cost due to the reduction in time and materials required to fabricate an optimal taper with a waist length of only 2 mm. The in-situ tapering technique can be extended to optimizing microstructured optical fiber (MOF) for SCG10 or tuning of the passband of MOFs, 11 optimizing tapered fiber pairs for fused fiber couplers12 and wavelength division multiplexers (WDMs), 13 or modifying dispersion compensation for compression or stretching of optical pulses.14-16 PMID:23748947

  6. Fully automated lobe-based airway taper index calculation in a low dose MDCT CF study over 4 time-points

    NASA Astrophysics Data System (ADS)

    Weinheimer, Oliver; Wielpütz, Mark O.; Konietzke, Philip; Heussel, Claus P.; Kauczor, Hans-Ulrich; Brochhausen, Christoph; Hollemann, David; Savage, Dasha; Galbán, Craig J.; Robinson, Terry E.

    2017-02-01

    Cystic Fibrosis (CF) results in severe bronchiectasis in nearly all cases. Bronchiectasis is a disease where parts of the airways are permanently dilated. The development and the progression of bronchiectasis is not evenly distributed over the entire lungs - rather, individual functional units are affected differently. We developed a fully automated method for the precise calculation of lobe-based airway taper indices. To calculate taper indices, some preparatory algorithms are needed. The airway tree is segmented, skeletonized and transformed to a rooted acyclic graph. This graph is used to label the airways. Then a modified version of the previously validated integral based method (IBM) for airway geometry determination is utilized. The rooted graph, the airway lumen and wall information are then used to calculate the airway taper indices. Using a computer-generated phantom simulating 10 cross sections of airways we present results showing a high accuracy of the modified IBM. The new taper index calculation method was applied to 144 volumetric inspiratory low-dose MDCT scans. The scans were acquired from 36 children with mild CF at 4 time-points (baseline, 3 month, 1 year, 2 years). We found a moderate correlation with the visual lobar Brody bronchiectasis scores by three raters (r2 = 0.36, p < .0001). The taper index has the potential to be a precise imaging biomarker but further improvements are needed. In combination with other imaging biomarkers, taper index calculation can be an important tool for monitoring the progression and the individual treatment of patients with bronchiectasis.

  7. Three-dimensional patterning in polymer optical waveguides using focused ion beam milling

    NASA Astrophysics Data System (ADS)

    Kruse, Kevin; Burrell, Derek; Middlebrook, Christopher

    2016-07-01

    Waveguide (WG) photonic-bridge taper modules are designed for symmetric planar coupling between silicon WGs and single-mode fibers (SMFs) to minimize photonic chip and packaging footprint requirements with improving broadband functionality. Micromachined fabrication and evaluation of polymer WG tapers utilizing high-resolution focused ion beam (FIB) milling is performed and presented. Polymer etch rates utilizing the FIB and optimal methods for milling polymer tapers are identified for three-dimensional patterning. Polymer WG tapers with low sidewall roughness are manufactured utilizing FIB milling and optically tested for fabrication loss. FIB platforms utilize a focused beam of ions (Ga+) to etch submicron patterns into substrates. Fabricating low-loss polymer WG taper prototypes with the FIB before moving on to mass-production techniques provides theoretical understanding of the polymer taper and its feasibility for connectorization devices between silicon WGs and SMFs.

  8. Free torsional vibrations of tapered cantilever I-beams

    NASA Astrophysics Data System (ADS)

    Rao, C. Kameswara; Mirza, S.

    1988-08-01

    Torsional vibration characteristics of linearly tapered cantilever I-beams have been studied by using the Galerkin finite element method. A third degree polynomial is assumed for the angle of twist. The analysis presented is valid for long beams and includes the effect of warping. The individual as well as combined effects of linear tapers in the width of the flanges and the depth of the web on the torsional vibration of cantilever I-beams are investigated. Numerical results generated for various values of taper ratios are presented in graphical form.

  9. Centering Ability of ProTaper Next and WaveOne Classic in J-Shape Simulated Root Canals

    PubMed Central

    Dioguardi, Mario; Cocco, Armando; Giuliani, Michele; Fabiani, Cristiano; D'Alessandro, Alfonso; Ciavarella, Domenico

    2016-01-01

    Introduction. The aim of this study was to evaluate and compare the shaping and centering ability of ProTaper Next (PTN; Dentsply Maillefer, Ballaigues, Switzerland) and WaveOne Classic systems (Dentsply Maillefer) in simulated root canals. Methods. Forty J-shaped canals in resin blocks were assigned to two groups (n = 20 for each group). Photographic method was used to record pre- and postinstrumentation images. After superimposition, centering and shaping ability were recorded at 9 different levels from the apex using the software Autocad 2013 (Autodesk Inc., San Rafael, USA). Results. Shaping procedures with ProTaper Next resulted in a lower amount of resin removed at each reference point level. In addition, the pattern of centering ability improved after the use of ProTaper Next in 8 of 9 measurement points. Conclusions. Within the limitations of this study, shaping procedures with ProTaper Next instruments demonstrated a lower amount of resin removed and a better centering ability than WaveOne Classic system. PMID:28054031

  10. Centering Ability of ProTaper Next and WaveOne Classic in J-Shape Simulated Root Canals.

    PubMed

    Troiano, Giuseppe; Dioguardi, Mario; Cocco, Armando; Giuliani, Michele; Fabiani, Cristiano; D'Alessandro, Alfonso; Ciavarella, Domenico; Lo Muzio, Lorenzo

    Introduction . The aim of this study was to evaluate and compare the shaping and centering ability of ProTaper Next (PTN; Dentsply Maillefer, Ballaigues, Switzerland) and WaveOne Classic systems (Dentsply Maillefer) in simulated root canals. Methods . Forty J-shaped canals in resin blocks were assigned to two groups ( n = 20 for each group). Photographic method was used to record pre- and postinstrumentation images. After superimposition, centering and shaping ability were recorded at 9 different levels from the apex using the software Autocad 2013 (Autodesk Inc., San Rafael, USA). Results . Shaping procedures with ProTaper Next resulted in a lower amount of resin removed at each reference point level. In addition, the pattern of centering ability improved after the use of ProTaper Next in 8 of 9 measurement points. Conclusions . Within the limitations of this study, shaping procedures with ProTaper Next instruments demonstrated a lower amount of resin removed and a better centering ability than WaveOne Classic system.

  11. Analyzing the costs to deliver medication therapy management services.

    PubMed

    Rupp, Michael T

    2011-01-01

    To provide pharmacy managers and consultant pharmacists with a step-by-step approach for analyzing of the costs of delivering medication therapy management (MTM) services and to describe use of a free online software application for determining costs of delivering MTM. The process described is applicable to community pharmacies and consultant pharmacists who provide MTM services from nonpharmacy settings. The PharmAccount Service Cost Calculator is an Internet- based software application that uses a guided online interview to collect information needed to conduct a comprehensive cost analysis of any specialized pharmacy service. In addition to direct variable and fixed costs, the software automatically allocates indirect and overhead costs to the service and generates an itemized report that details the components of service delivery costs. The service cost calculator is sufficiently flexible to support the analysis of virtually any specialized pharmacy service, irrespective of whether the service is being delivered from a physical pharmacy. The software application allows users to perform sensitivity analysis to quickly determine the potential impact that alternate scenarios would have on service delivery cost. It is therefore particularly well suited to assist in the design and planning of a new pharmacy service. Good management requires that the cost implications of service delivery decisions are known and considered. Analyzing the cost of an MTM service is an important step in developing a sustainable business model.

  12. [Prostate cancer: Quality assessment of clinical management in the Midi-Pyrenean region in 2011].

    PubMed

    Daubisse-Marliac, L; Lamy, S; Lunardi, P; Tollon, C; Thoulouzan, M; Latorzeff, I; Bauvin, E; Grosclaude, P

    2017-02-01

    Assessing the quality of the clinical management of prostate cancer in the Midi-Pyrenean region in 2011. The study population was randomly selected among new cases of prostate cancer presented in Multidisciplinary Team Meeting (MTM) in 2011. The indicators defined with the professionals have evaluated the quality of the diagnostic care, when treatment started and at the time of the MTM. Six hundred and thirty-three new patients were included (median age at diagnosis=69years, min: 48; max: 93). In diagnostic period, 92% of patients had a prostate biopsy. Performing a pelvic MRI, an abdomino-pelvic CT and bone scintigraphy concerned respectively 53%, 55% and 61% of intermediate or high-risk patients. The Gleason score, surgical margins and pathological stage were included in over 98% patient records treated by radical prostatectomy. A PSA assay in 3months after prostatectomy was found in 59% of surgical patients. The MTM was performed before treatment to 83% of patients. About three-quarters of surgical patients with stage pT≥3 or pN1 or with no healthy margins were discussed in MTM after surgery. Most of the studied indicators reach a high level. However, the lower level of realization of complementary examinations may question about their real place, accessibility and traceability. 4. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  13. 1.4-7.2  μm broadband supercontinuum generation in an As-S chalcogenide tapered fiber pumped in the normal dispersion regime.

    PubMed

    Wang, Yingying; Dai, Shixun; Li, Guangtao; Xu, Dong; You, Chenyang; Han, Xin; Zhang, Peiqing; Wang, Xunsi; Xu, Peipeng

    2017-09-01

    We report a broadband supercontinuum (SC) generation in chalcogenide (ChG) step-index tapered fibers pumped in the normal dispersion regime. The fibers consisting of As 2 S 3 core and As 38 S 62 cladding glasses were fabricated using the isolated stacked extrusion method. A homemade tapering platform allows us to accurately control the core diameters and transition region lengths of the tapered fibers. An SC generation spanning from 1.4 to 7.2 μm was achieved by pumping a 12-cm-long tapered fiber with femtosecond laser pulses at 3.25 μm. To the best of our knowledge, this is the broadest SC generation obtained experimentally in tapered fibers when pumped in the normal dispersion regime so far. The effects of waist diameter and transition region length of the tapered fiber on the SC spectral behavior were also investigated.

  14. Statistical Analyses of Raw Material Data for MTM45-1/CF7442A-36% RW: CMH Cure Cycle

    NASA Technical Reports Server (NTRS)

    Coroneos, Rula; Pai, Shantaram, S.; Murthy, Pappu

    2013-01-01

    This report describes statistical characterization of physical properties of the composite material system MTM45-1/CF7442A, which has been tested and is currently being considered for use on spacecraft structures. This composite system is made of 6K plain weave graphite fibers in a highly toughened resin system. This report summarizes the distribution types and statistical details of the tests and the conditions for the experimental data generated. These distributions will be used in multivariate regression analyses to help determine material and design allowables for similar material systems and to establish a procedure for other material systems. Additionally, these distributions will be used in future probabilistic analyses of spacecraft structures. The specific properties that are characterized are the ultimate strength, modulus, and Poisson??s ratio by using a commercially available statistical package. Results are displayed using graphical and semigraphical methods and are included in the accompanying appendixes.

  15. PLC-based mode multi/demultiplexers for mode division multiplexing

    NASA Astrophysics Data System (ADS)

    Saitoh, Kunimasa; Hanzawa, Nobutomo; Sakamoto, Taiji; Fujisawa, Takeshi; Yamashita, Yoko; Matsui, Takashi; Tsujikawa, Kyozo; Nakajima, Kazuhide

    2017-02-01

    Recently developed PLC-based mode multi/demultiplexers (MUX/DEMUXs) for mode division multiplexing (MDM) transmission are reviewed. We firstly show the operation principle and basic characteristics of PLC-based MUX/DEMUXs with an asymmetric directional coupler (ADC). We then demonstrate the 3-mode (2LP-mode) multiplexing of the LP01, LP11a, and LP11b modes by using fabricated PLC-based mode MUX/DEMUX on one chip. In order to excite LP11b mode in the same plane, a PLC-based LP11 mode rotator is introduced. Finally, we show the PLC-based 6-mode (4LP-mode) MUX/DEMUX with a uniform height by using ADCs, LP11 mode rotators, and tapered waveguides. It is shown that the LP21a mode can be excited from the LP11b mode by using ADC, and the two nearly degenerated LP21b and LP02 modes can be (de)multiplexed separately by using tapered mode converter from E13 (E31) mode to LP21b (LP02) mode.

  16. Medication therapy management and condition care services in a community-based employer setting.

    PubMed

    Johannigman, Mark J; Leifheit, Michael; Bellman, Nick; Pierce, Tracey; Marriott, Angela; Bishop, Cheryl

    2010-08-15

    A program in which health-system pharmacists and pharmacy technicians provide medication therapy management (MTM), wellness, and condition care (disease management) services under contract with local businesses is described. The health-system pharmacy department's Center for Medication Management contracts directly with company benefits departments for defined services to participating employees. The services include an initial wellness and MTM session and, for certain patients identified during the initial session, ongoing condition care. The initial appointment includes a medication history, point-of-care testing for serum lipids and glucose, body composition analysis, and completion of a health risk assessment. The pharmacist conducts a structured MTM session, reviews the patient's test results and risk factors, provides health education, discusses opportunities for cost savings, and documents all activities on the patient's medication action plan. Eligibility for the condition care program is based on a diagnosis of diabetes, hypertension, asthma, heart failure, or hyperlipidemia or elevation of lipid or glucose levels. Findings are summarized for employers after the initial wellness screening and at six-month intervals. Patients receiving condition care sign a customized contract, establish goals, attend up to four MTM sessions per year, and track their information on a website; employers may offer incentives for participation. When pharmacists recommend adjustments to therapy or cost-saving changes, it is up to patients to discuss these with their physician. A survey completed by each patient after the initial wellness session has indicated high satisfaction. Direct cost savings related to medication changes have averaged $253 per patient per year. Total cost savings to companies in the first year of the program averaged $1011 per patient. For the health system, the program has been financially sustainable. Key laboratory values indicate positive clinical outcomes. A business model in which health-system pharmacists provide MTM and condition care services for company employees has demonstrated successful outcomes in terms of patient satisfaction, cost savings, and clinical benefits.

  17. Tapered fluorotellurite microstructured fibers for broadband supercontinuum generation.

    PubMed

    Wang, Fang; Wang, Kangkang; Yao, Chuanfei; Jia, Zhixu; Wang, Shunbin; Wu, Changfeng; Qin, Guanshi; Ohishi, Yasutake; Qin, Weiping

    2016-02-01

    Fluorotellurite microstructured fibers (MFs) based on TeO2-BaF2-Y2O3 glasses are fabricated by using a rod-in-tube method. Tapered fluorotellurite MFs with varied transition region lengths are prepared by employing an elongation machine. By using a tapered fluorotellurite MF with a transition region length of ∼3.3  cm as the nonlinear medium and a 1560 nm femtosecond fiber laser as the pump source, broadband supercontinuum generation covering from 470 to 2770 nm is obtained. The effects of the transition region length of the tapered fluorotellurite MF on supercontinuum generation are also investigated. Our results show that tapered fluorotellurite MFs are promising nonlinear media for generating broadband supercontinuum light expanding from visible to mid-infrared spectral region.

  18. Joining Tubes With Adhesive

    NASA Technical Reports Server (NTRS)

    Bateman, W. A.

    1984-01-01

    Cylindrical tubes joined together, end to end, by method employing adhesive, tapered ends, and spacing wires. Tapered joint between tubular structural elements provides pressure between bonding surfaces during adhesive curing. Spacing wires prevent adhesive from being scraped away when one element inserted in other. Method developed for assembling structural elements made of composite materials.

  19. High pressure flow-rate switch

    NASA Technical Reports Server (NTRS)

    Gale, G. P.

    1970-01-01

    Flow-rate switch adjusts easily over a wide switching range and operates uniformly over many cycles. It adapts easily to control of various fluids and has the possibility of introducing multi-point switching. Novel design features include the tapered spool, balanced porting, capillary-bypass lubrication, and capillary-restriction damping.

  20. Synthesis of Tapered CdS Nanobelts and CdSe Nanowires with Good Optical Property by Hydrogen-Assisted Thermal Evaporation

    PubMed Central

    2009-01-01

    The tapered CdS nanobelts and CdSe nanowires were prepared by hydrogen-assisted thermal evaporation method. Different supersaturation leads to two different kinds of 1D nanostructures. The PL measurements recorded from the as-prepared tapered CdS nanobelts and CdSe nanowires show only a bandgap emission with relatively narrow full-width half maximum, which means that they possess good optical property. The as-synthesized high-quality tapered CdS nanobelts and CdSe nanowires may be excellent building blocks for photonic devices. PMID:20596418

  1. Tapered polysilicon core fibers for nonlinear photonics.

    PubMed

    Suhailin, Fariza H; Shen, Li; Healy, Noel; Xiao, Limin; Jones, Maxwell; Hawkins, Thomas; Ballato, John; Gibson, Ursula J; Peacock, Anna C

    2016-04-01

    We propose and demonstrate a novel approach to obtaining small-core polysilicon waveguides from the silicon fiber platform. The fibers were fabricated via a conventional drawing tower method and, subsequently, tapered down to achieve silicon core diameters of ∼1  μm, the smallest optical cores for this class of fiber to date. Characterization of the material properties have shown that the taper process helps to improve the local crystallinity of the silicon core, resulting in a significant reduction in the material loss. By exploiting the combination of small cores and low losses, these tapered fibers have enabled the first observation of nonlinear transmission within a polycrystalline silicon waveguide of any type. As the fiber drawing method is highly scalable, it opens a route for the development of low-cost and flexible nonlinear silicon photonic systems.

  2. Compact Single-Layer Traveling-Wave Antenna DesignUsing Metamaterial Transmission Lines

    NASA Astrophysics Data System (ADS)

    Alibakhshikenari, Mohammad; Virdee, Bal Singh; Limiti, Ernesto

    2017-12-01

    This paper presents a single-layer traveling-wave antenna (TWA) that is based on composite right/left-handed (CRLH)-metamaterial (MTM) transmission line (TL) structure, which is implemented by using a combination of interdigital capacitors and dual-spiral inductive slots. By embedding dual-spiral inductive slots inside the CRLH MTM-TL results in a compact TWA. Dimensions of the proposed CRLH MTM-TL TWA is 21.5 × 30.0 mm2 or 0.372λ0 × 0.520λ0 at 5.2 GHz (center frequency). The fabricated TWA operates over 1.8-8.6 GHz with a fractional bandwidth greater than 120%, and it exhibits a peak gain and radiation efficiency of 4.2 dBi and 81%, respectively, at 5 GHz. By avoiding the use of lumped components, via-holes or defected ground structures, the proposed TWA design is economic for mass production as well as easy to integrate with wireless communication systems.

  3. Ultra-small single-negative electric metamaterials for electromagnetic coupling reduction of microstrip antenna array.

    PubMed

    Xu, He-Xiu; Wang, Guang-Ming; Qi, Mei-Qing; Zeng, Hui-Yong

    2012-09-24

    We report initially the design, fabrication and measurement of using waveguided electric metamaterials (MTM) in the design of closely-spaced microtrip antenna arrays with mutual coupling reduction. The complementary spiral ring resonators (CSRs) which exhibit single negative resonant permittivity around 3.5GHz are used as the basic electric MTM element. For verification, two CSRs with two and three concentric rings are considered, respectively. By properly arranging these well engineered waveguided MTMs between two H-plane coupled patch antennas, both numerical and measured results indicate that more than 8.4 dB mutual coupling reduction is obtained. The mechanism has been studied from a physical insight. The electric MTM element is electrically small, enabling the resultant antenna array to exhibit a small separation (λo/8 at the operating wavelength) and thus a high directivity. The proposed strategy opens an avenue to new types of antenna with super performances and can be generalized for other electric resonators.

  4. Near-field fluorescence thermometry using highly efficient triple-tapered near-field optical fiber probe.

    PubMed

    Fujii, T; Taguchi, Y; Saiki, T; Nagasaka, Y

    2012-12-01

    A novel local temperature measurement method using fluorescence near-field optics thermal nanoscopy (Fluor-NOTN) has been developed. Fluor-NOTN enables nanoscale temperature measurement in situ by detecting the temperature-dependent fluorescence lifetime of CdSe quantum dots (QDs). In this paper, we report a novel triple-tapered near-field optical fiber probe that can increase the temperature measurement sensitivity of Fluor-NOTN. The performance of the proposed probe was numerically evaluated by the finite difference time domain method. Due to improvements in both the throughput and collection efficiency of near-field light, the sensitivity of the proposed probe was 1.9 times greater than that of typical double-tapered probe. The proposed shape of the triple-tapered core was successfully fabricated utilizing a geometrical model. The detected signal intensity of dried layers of QDs was greater by more than two orders than that of auto-fluorescence from the fiber core. In addition, the near-field fluorescence lifetime of the QDs and its temperature dependence were successfully measured by the fabricated triple-tapered near-field optical fiber probe. These measurement results verified the capability of the proposed triple-tapered near-field optical fiber probe to improve the collection efficiency of near-field fluorescence.

  5. Comparative evaluation of apically extruded debris with V-Taper, ProTaper Next, and the Self-adjusting File systems

    PubMed Central

    Vyavahare, Nishant K.; Raghavendra, Srinidhi Surya; Desai, Niranjan N.

    2016-01-01

    Background: Complete cleaning of the root canal is the goal for ensuring success in endodontics. Removal of debris plays an important role in achieving this goal. In spite of advancements in instrument design, apical extrusion of debris remains a source of inflammation in the periradicular region. Aim: To comparatively evaluate the amount of apically extruded debris with V-Taper, ProTaper Next, and the self-adjusting File (SAF) system. Materials and Methods: Sixty-four extracted human mandibular teeth with straight root canals were taken. Access openings were done and working length determined. The samples were randomly divided into three groups: Group I - V-Taper files (n = 20), Group II - ProTaper Next (n = 20), Group III - SAF (n = 20). Biomechanical preparation was completed and the debris collected in vials to be quantitatively determined. The data obtained was statistically analyzed using ANOVA and post hoc Tukey's test. Results: All the specimens showed apical debris extrusion. SAF showed significantly less debris extrusion compared to V-Taper and ProTaper Next (P < 0.001). Among Groups I and II, ProTaper Next showed lesser debris extrusion as compared to V-Taper, but it was not significant (P = 0.124). Conclusion: The SAF showed least amount of apical debris extrusion when compared to newer rotary endodontic instruments. This indicates that the incidence of inter-treatment flare-ups due to debris extrusion would be less with the SAF. PMID:27217636

  6. Measurement of pattern roughness and local size variation using CD-SEM: current status

    NASA Astrophysics Data System (ADS)

    Fukuda, Hiroshi; Kawasaki, Takahiro; Kawada, Hiroki; Sakai, Kei; Kato, Takashi; Yamaguchi, Satoru; Ikota, Masami; Momonoi, Yoshinori

    2018-03-01

    Measurement of line edge roughness (LER) is discussed from four aspects: edge detection, PSD prediction, sampling strategy, and noise mitigation, and general guidelines and practical solutions for LER measurement today are introduced. Advanced edge detection algorithms such as wave-matching method are shown effective for robustly detecting edges from low SNR images, while conventional algorithm with weak filtering is still effective in suppressing SEM noise and aliasing. Advanced PSD prediction method such as multi-taper method is effective in suppressing sampling noise within a line edge to analyze, while number of lines is still required for suppressing line to line variation. Two types of SEM noise mitigation methods, "apparent noise floor" subtraction method and LER-noise decomposition using regression analysis are verified to successfully mitigate SEM noise from PSD curves. These results are extended to LCDU measurement to clarify the impact of SEM noise and sampling noise on LCDU.

  7. A New Mechanism of Sound Generation in Songbirds

    NASA Astrophysics Data System (ADS)

    Goller, Franz; Larsen, Ole N.

    1997-12-01

    Our current understanding of the sound-generating mechanism in the songbird vocal organ, the syrinx, is based on indirect evidence and theoretical treatments. The classical avian model of sound production postulates that the medial tympaniform membranes (MTM) are the principal sound generators. We tested the role of the MTM in sound generation and studied the songbird syrinx more directly by filming it endoscopically. After we surgically incapacitated the MTM as a vibratory source, zebra finches and cardinals were not only able to vocalize, but sang nearly normal song. This result shows clearly that the MTM are not the principal sound source. The endoscopic images of the intact songbird syrinx during spontaneous and brain stimulation-induced vocalizations illustrate the dynamics of syringeal reconfiguration before phonation and suggest a different model for sound production. Phonation is initiated by rostrad movement and stretching of the syrinx. At the same time, the syrinx is closed through movement of two soft tissue masses, the medial and lateral labia, into the bronchial lumen. Sound production always is accompanied by vibratory motions of both labia, indicating that these vibrations may be the sound source. However, because of the low temporal resolution of the imaging system, the frequency and phase of labial vibrations could not be assessed in relation to that of the generated sound. Nevertheless, in contrast to the previous model, these observations show that both labia contribute to aperture control and strongly suggest that they play an important role as principal sound generators.

  8. Fretting-corrosion at the modular tapers interface: Inspection of standard ASTM F1875-98.

    PubMed

    Bingley, Rachel; Martin, Alan; Manfredi, Olivia; Nejadhamzeeigilani, Mahdiyar; Oladokun, Abimbola; Beadling, Andrew Robert; Siddiqui, Sohail; Anderson, James; Thompson, Jonathan; Neville, Anne; Bryant, Michael

    2018-05-01

    Interest in the degradation mechanisms at the modular tapers interfaces has been renewed due to increased reported cases of adverse reactions to metal debris and the appearance of wear and corrosion at the modular tapers interfaces at revision. Over the past two decades, a lot of research has been expended to understand the degradation mechanisms, with two primary implant loading procedures and orientations used consistently across the literature. ASTM F1875-98 is often used as a guide to understand and benchmark the tribocorrosion processes occurring within the modular tapers interface. This article presents a comparison of the two methods outlined in ASTM F1875-98 as well as a critique of the standard considering the current paradigm in pre-clinical assessment of modular tapers.

  9. Do Stem Taper Microgrooves Influence Taper Corrosion in Total Hip Arthroplasty? A Matched Cohort Retrieval Study

    PubMed Central

    Arnholt, Christina M.; MacDonald, Daniel W.; Underwood, Richard; Guyer, Eric P.; Rimnac, Clare M.; Kurtz, Steven M.; Mont, Michael A.; Klein, Gregg; Lee, Gwo-Chin; Chen, Antonia F.; Hamlin, Brian; Cates, Harold; Malkani, Arthur; Kraay, Matthew

    2017-01-01

    Background Previous studies identified imprinting of the stem morphology onto the interior head bore, leading researchers to hypothesize an influence of taper topography on mechanically assisted crevice corrosion (MACC). The purpose of this study was to analyze whether micro-grooved stem tapers result in greater fretting corrosion damage than smooth stem tapers. Methods A matched cohort of 120 retrieved head-stem pairs from metal-on-polyethylene bearings was created controlling for implantation time, flexural rigidity, apparent length of engagement, and head size. There were two groups of 60 heads each, mated with either smooth or micro-grooved stem tapers. A high precision roundness machine was used to measure and categorize the surface morphology. Fretting corrosion damage at the head/neck junction was characterized using the Higgs-Goldberg scoring method. Fourteen of the most damaged heads, were analyzed for the maximum depth of material loss and focused ion beam (FIB) cross-sectioned to view oxide and base metal. Results Fretting corrosion damage was not different between the two cohorts at the femoral head (p = 0.14, Mann Whitney) or stem tapers (p = 0.35). There was no difference in the maximum depths of material loss between the cohorts (p = 0.71). Cross sectioning revealed contact damage, signs of micro-motion, and chromium rich oxide layers in both cohorts. Micro-groove imprinting did not appear to have a different effect on the fretting corrosion behavior. Conclusion The results of this matched cohort retrieval study do not support the hypothesis that taper surfaces with micro-grooved stems exhibit increased in vivo fretting corrosion damage or material release. PMID:28111124

  10. Quantification of the Contact Area at the Head-Stem Taper Interface of Modular Hip Prostheses.

    PubMed

    Witt, Florian; Gührs, Julian; Morlock, Michael M; Bishop, Nicholas E

    2015-01-01

    Corrosion of modular taper junctions of hip implants may be associated with clinical failure. Taper design parameters, as well as the intraoperatively applied assembly forces, have been proposed to affect corrosion. Fretting corrosion is related to relative interface shear motion and fluid ingress, which may vary with contact force and area. It was hypothesised in this study that assembly forces modify the extent and distribution of the surface contact area at the taper interface between a cobalt chrome head and titanium stem taper with a standard threaded surface profile. Local abrasion of a thin gold coating applied to the stem taper prior to assembly was used to determine the contact area after disassembly. Profilometry was then used to assess permanent deformation of the stem taper surface profile. With increasing assembly force (500 N, 2000 N, 4000 N and 8000 N) the number of stem taper surface profile ridges in contact with the head taper was found to increase (9.2±9.3%, 65.4±10.8%, 92.8±6.0% and 100%) and the overall taper area in contact was also found to increase (0.6±0.7%, 5.5±1.0%, 9.9±1.1% and 16.1±0.9%). Contact was inconsistently distributed over the length of the taper. An increase in plastic radial deformation of the surface ridges (-0.05±0.14 μm, 0.1±0.14 μm, 0.21±0.22 μm and 0.96±0.25 μm) was also observed with increasing assembly force. The limited contact of the taper surface ridges at lower assembly forces may influence corrosion rates, suggesting that the magnitude of the assembly force may affect clinical outcome. The method presented provides a simple and practical assessment of the contact area at the taper interface.

  11. Quantification of the Contact Area at the Head-Stem Taper Interface of Modular Hip Prostheses

    PubMed Central

    Witt, Florian; Gührs, Julian; Morlock, Michael M.; Bishop, Nicholas E.

    2015-01-01

    Corrosion of modular taper junctions of hip implants may be associated with clinical failure. Taper design parameters, as well as the intraoperatively applied assembly forces, have been proposed to affect corrosion. Fretting corrosion is related to relative interface shear motion and fluid ingress, which may vary with contact force and area. It was hypothesised in this study that assembly forces modify the extent and distribution of the surface contact area at the taper interface between a cobalt chrome head and titanium stem taper with a standard threaded surface profile. Local abrasion of a thin gold coating applied to the stem taper prior to assembly was used to determine the contact area after disassembly. Profilometry was then used to assess permanent deformation of the stem taper surface profile. With increasing assembly force (500 N, 2000 N, 4000 N and 8000 N) the number of stem taper surface profile ridges in contact with the head taper was found to increase (9.2±9.3%, 65.4±10.8%, 92.8±6.0% and 100%) and the overall taper area in contact was also found to increase (0.6±0.7%, 5.5±1.0%, 9.9±1.1% and 16.1±0.9%). Contact was inconsistently distributed over the length of the taper. An increase in plastic radial deformation of the surface ridges (-0.05±0.14 μm, 0.1±0.14 μm, 0.21±0.22 μm and 0.96±0.25 μm) was also observed with increasing assembly force. The limited contact of the taper surface ridges at lower assembly forces may influence corrosion rates, suggesting that the magnitude of the assembly force may affect clinical outcome. The method presented provides a simple and practical assessment of the contact area at the taper interface. PMID:26280914

  12. Optimizing treatment with tumour necrosis factor inhibitors in rheumatoid arthritis—a proof of principle and exploratory trial: is dose tapering practical in good responders?

    PubMed Central

    Lorente-Cánovas, Beatriz; Doré, Caroline J; Bosworth, Ailsa; Ma, Margaret H; Galloway, James B; Cope, Andrew P; Pande, Ira; Walker, David; Scott, David L

    2017-01-01

    Abstract Objectives RA patients receiving TNF inhibitors (TNFi) usually maintain their initial doses. The aim of the Optimizing Treatment with Tumour Necrosis Factor Inhibitors in Rheumatoid Arthritis trial was to evaluate whether tapering TNFi doses causes loss of clinical response. Methods We enrolled RA patients receiving etanercept or adalimumab and a DMARD with DAS28 under 3.2 for over 3 months. Initially (months 0–6) patients were randomized to control (constant TNFi) or two experimental groups (tapering TNFi by 33 or 66%). Subsequently (months 6–12) control subjects were randomized to taper TNFi by 33 or 66%. Disease flares (DAS28 increasing ⩾0.6 with at least one additional swollen joint) were the primary outcome. Results Two hundred and forty-four patients were screened, 103 randomized and 97 treated. In months 0–6 there were 8/50 (16%) flares in controls, 3/26 (12%) with 33% tapering and 6/21 (29%) with 66% tapering. Multivariate Cox analysis showed time to flare was unchanged with 33% tapering but was reduced with 66% tapering compared with controls (adjusted hazard ratio 2.81, 95% CI: 0.99, 7.94; P = 0.051). Analysing all tapered patients after controls were re-randomized (months 6–12) showed differences between groups: there were 6/48 (13%) flares with 33% tapering and 14/39 (36%) with 66% tapering. Multivariate Cox analysis showed 66% tapering reduced time to flare (adjusted hazard ratio 3.47, 95% CI: 1.26, 9.58; P = 0.016). Conclusion Tapering TNFi by 33% has no impact on disease flares and appears practical in patients in sustained remission and low disease activity states. Trail registration EudraCT, https://www.clinicaltrialsregister.eu, 2010-020738-24; ISRCTN registry, https://www.isrctn.com, 28955701 PMID:28968858

  13. Enhancing separation in short-capillary electrophoresis via pressure-driven backflow.

    PubMed

    Tian, Miaomiao; Wang, Yujia; Mohamed, Amara Camara; Guo, Liping; Yang, Li

    2015-07-01

    We present a novel easy-to-operate and efficient method to improve the separation efficiency in short-capillary electrophoresis by introducing steady backflow to counterbalance electro-osmotic flow without the use of any external pressure. The backflow was easily generated by tapering the capillary end, which was achieved by heating a straight capillary and stretching it with a constant force. We investigated the net fluidic transport rate under different tip lengths and separation voltages. Good run-to-run repeatability and capillary-to-capillary reproducibility of the present method were obtained with RSD less than 1.5%, indicating the stability of the fluid transport rate in the tapered capillary, which ensures the quantification and repeatability of capillary zone electrophoresis (CZE) analysis. Enhanced separation of the tapered short capillary electrophoresis was demonstrated by CZE analyzing amino acids and positional isomers. Baseline separations were achieved in less than 60 s using a tapered capillary with the effective length of 5 cm, while no separation was achieved using a normal capillary without a tapered tip. The present study provides a promising method to use pressure-driven backflow to enhance separation efficiency in short-capillary electrophoresis, which would be of potential value in a wide application for fast analysis of complex samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. One New Method to Generate 3-Dimensional Virtual Mannequin

    NASA Astrophysics Data System (ADS)

    Xiu-jin, Shi; Zhi-jun, Wang; Jia-jin, Le

    The personal virtual mannequin is very important in electronic made to measure (eMTM) system. There is one new easy method to generate personal virtual mannequin. First, the characteristic information of customer's body is got from two photos. Secondly, some human body part templates corresponding with the customer are selected from the templates library. Thirdly, these templates are modified and assembled according to certain rules to generate a personalized 3-dimensional human, and then the virtual mannequin is realized. Experimental result shows that the method is easy and feasible.

  15. Secular spring rainfall variability at local scale over Ethiopia: trend and associated dynamics

    NASA Astrophysics Data System (ADS)

    Tsidu, Gizaw Mengistu

    2017-10-01

    Spring rainfall secular variability is studied using observations, reanalysis, and model simulations. The joint coherent spatio-temporal secular variability of gridded monthly gauge rainfall over Ethiopia, ERA-Interim atmospheric variables and sea surface temperature (SST) from Hadley Centre Sea Ice and SST (HadISST) data set is extracted using multi-taper method singular value decomposition (MTM-SVD). The contemporaneous associations are further examined using partial Granger causality to determine presence of causal linkage between any of the climate variables. This analysis reveals that only the northwestern Indian Ocean secular SST anomaly has direct causal links with spring rainfall over Ethiopia and mean sea level pressure (MSLP) over Africa inspite of the strong secular covariance of spring rainfall, SST in parts of subtropical Pacific, Atlantic, Indian Ocean and MSLP. High secular rainfall variance and statistically significant linear trend show consistently that there is a massive decline in spring rain over southern Ethiopia. This happened concurrently with significant buildup of MSLP over East Africa, northeastern Africa including parts of the Arabian Peninsula, some parts of central Africa and SST warming over all ocean basins with the exception of the ENSO regions. The east-west pressure gradient in response to the Indian Ocean warming led to secular southeasterly winds over the Arabian Sea, easterly over central Africa and equatorial Atlantic. These flows weakened climatological northeasterly flow over the Arabian Sea and southwesterly flow over equatorial Atlantic and Congo basins which supply moisture into the eastern Africa regions in spring. The secular divergent flow at low level is concurrent with upper level convergence due to the easterly secular anomalous flow. The mechanisms through which the northwestern Indian Ocean secular SST anomaly modulates rainfall are further explored in the context of East Africa using a simplified atmospheric general circulation model (AGCM) coupled to mixed-layer oceanic model. The rainfall anomaly (with respect to control simulation), forced by the northwestern Indian Ocean secular SST anomaly and averaged over the 30-year period, exhibits prevalence of dry conditions over East and equatorial Africa in agreement with observation. The atmospheric response to secular SST warming anomaly led to divergent flow at low levels and subsidence at the upper troposphere over regions north of 5° S on the continent and vice versa over the Indian Ocean. This surface difluence over East Africa, in addition to its role in suppressing convective activity, deprives the region of moisture supply from the Indian Ocean as well as the Atlantic and Congo basins.

  16. Vertical Root Fracture initiation in curved roots after root canal preparation: A dentinal micro-crack analysis with LED transillumination

    PubMed Central

    Martín-Biedma, Benjamín; Varela-Patiño, Purificación; Ruíz-Piñón, Manuel; Castelo-Baz, Pablo

    2017-01-01

    Background One of the causative factors of root defects is the increased friction produced by rotary instrumentation. A high canal curvature may increase stress, making the tooth more susceptible to dentinal cracks. The purpose of this study was to evaluate dentinal micro-crack formation with the ProTaper NEXT and ProTaper Universal systems using LED transillumination, and to analyze the micro-crack generated at the point of maximum canal curvature. Material and Methods 60 human mandibular premolars with curvatures between 30–49° and radii between 2–4 mm were used. The root canals were instrumented using the Protaper Universal® and Protaper NEXT® systems, with the aid of the Proglider® system. The obtained samples were sectioned transversely before subsequent analysis with LED transillumination at 2 mm and 8 mm from the apex and at the point of maximum canal curvature. Defects were scored: 0 for no defects; and 1 for micro-cracks. Results Root defects were not observed in the control group. The ProTaper NEXT system caused fewer defects (16.7%) than the ProTaper Universal system (40%) (P<0.05). The ProTaper Universal system caused significantly more micro-cracks at the point of maximum canal curvature than the ProTaper NEXT system (P<0.05). Conclusions Rotary instrumentation systems often generate root defects, but the ProTaper NEXT system generated fewer dentinal defects than the ProTaper Universal system. A higher prevalence of defects was found at the point of maximum curvature in the ProTaper Universal group. Key words:Curved root, Micro-crack, point of maximum canal curvature, ProTaper NEXT, ProTaper Universal, Vertical root fracture. PMID:29167712

  17. Comparison of debris extruded apically and working time used by ProTaper Universal rotary and ProTaper retreatment system during gutta-percha removal

    PubMed Central

    UEZU, Mary Kinue Nakamune; BRITTO, Maria Leticia Borges; NABESHIMA, Cleber K.; PALLOTTA, Raul Capp

    2010-01-01

    Objective The aim of this study was to evaluate the in vitro action of ProTaper retreatment files and ProTaper Universal in the retreatment of mandibular premolars. Material and methods The amount of debris extruded apically was measured and the time to reach the working length and to complete the removal of gutta-percha was observed. Thirty teeth had their canals prepared using ProTaper Universal files and were obturated by the single cone technique. The teeth were then stored at 37ºC in a humid environment for 7 days. During the use of the rotary instruments for root canal filling removal, the apical portions of the teeth were attached to the open end of a resin tube to collect the apically extruded debris. Results ProTaper Universal files were significantly faster (p=0.0011) than the ProTaper retreatment files to perform gutta-percha removal, but no significant difference was found between the files regarding the time to reach the working length or the amount of apical extrusion. Conclusions ProTaper Universal rotary had better results for endodontic retreatment, and both techniques promote similar apical extrusion of debris. PMID:21308282

  18. Strain energy release rate analysis of delamination in a tapered laminate subjected to tension load

    NASA Technical Reports Server (NTRS)

    Salpekar, S. A.; Raju, I. S.; Obrien, T. K.

    1990-01-01

    A tapered composite laminate subjected to tension load was analyzed using the finite-element method. The glass/epoxy laminate has a (+ or - 45)sub 3 group of plies dropped in three distinct steps, each 20 ply-thicknesses apart, thus forming a taper angle of 5.71 degrees. Steep gradients of interlaminar normal and shear stress on a potential delamination interface suggest the existence of stress singularities at the points of material and geometric discontinuities created by the internal plydrops. The delamination was assumed to initiate at the thin end of the taper on a -45/+45 interface and the delamination growth was simulated in both directions, i.e., along the taper and into the thin region. The strain-energy-release rate for a delamination growing into the thin laminate consisted predominantly of mode I (opening) component. For a delamination growing along the tapered region, the strain-energy-release rate was initially all mode I, but the proportion of mode I decreased with increase in delamination size until eventually total G was all mode II. The total G for both delamination tips increased with increase in delamination size, indicating that a delamination initiating at the end of the taper will grow unstably along the taper and into the thin laminate simultaneously.

  19. Parametric analysis of swept-wing geometry with sheared wing tips

    NASA Technical Reports Server (NTRS)

    Fremaux, C. M.; Vijgen, P. M. H. W.; Van Dam, C. P.

    1990-01-01

    A computational parameter study is presented of potential reductions in induced drag and increases in lateral-directional stability due to sheared wing tips attached to an untwisted wing of moderate sweep and aspect ratio. Sheared tips are swept and tapered wing-tip devices mounted in the plane of the wing. The induced-drag results are obtained using an inviscid, incompressible surface-panel method that models the nonlinear effects due to the deflected and rolled-up wake behind the lifting surface. The induced-drag results with planar sheared tips are compared to straight-tapered tip extensions and nonplanar winglet geometries. The lateral-directional static-stability characteristics of the wing with sheared tips are estimated using a quasi-vortex-lattice method. For certain combinations of sheared-tip sweep and taper, both the induced efficiency of the wing and the relevant static-stability derivatives are predicted to increase compared to the wing with a straight-tapered tip modification.

  20. Identification of a mutation in the MTM1 gene, associated with X-linked myotubular myopathy, in a Greek family

    PubMed Central

    Fidani, L; Karagianni, P; Tsakalidis, C; Mitsiako, G; Hatziioannidis, I; Biancalana, V; Nikolaidis, N

    2011-01-01

    X-linked myotubular myopathy (XLMTM) is a rare congenital myopathy, usually characterized by severe hypotonia and respiratory insufficiency at birth, in affected, male infants. The disease is causally associated with mutations in the MTM1 gene, coding for phosphatase myotubularin. We report a severe case of XLMTM with a novel mutation, at a donor splicing site (c.1467+1G) previously associated with severe phenotype. The mutation was also identified in the patient's mother, providing an opportunity for sound genetic counseling. PMID:22435031

  1. Identification of a mutation in the MTM1 gene, associated with X-linked myotubular myopathy, in a Greek family.

    PubMed

    Fidani, L; Karagianni, P; Tsakalidis, C; Mitsiako, G; Hatziioannidis, I; Biancalana, V; Nikolaidis, N

    2011-07-01

    X-linked myotubular myopathy (XLMTM) is a rare congenital myopathy, usually characterized by severe hypotonia and respiratory insufficiency at birth, in affected, male infants. The disease is causally associated with mutations in the MTM1 gene, coding for phosphatase myotubularin. We report a severe case of XLMTM with a novel mutation, at a donor splicing site (c.1467+1G) previously associated with severe phenotype. The mutation was also identified in the patient's mother, providing an opportunity for sound genetic counseling.

  2. The experimental and calculated characteristics of 22 tapered wings

    NASA Technical Reports Server (NTRS)

    Anderson, Raymond F

    1938-01-01

    The experimental and calculated aerodynamic characteristics of 22 tapered wings are compared, using tests made in the variable-density wind tunnel. The wings had aspect ratios from 6 to 12 and taper ratios from 1:6:1 and 5:1. The compared characteristics are the pitching moment, the aerodynamic-center position, the lift-curve slope, the maximum lift coefficient, and the curves of drag. The method of obtaining the calculated values is based on the use of wing theory and experimentally determined airfoil section data. In general, the experimental and calculated characteristics are in sufficiently good agreement that the method may be applied to many problems of airplane design.

  3. High-sensitivity refractive index sensors based on fused tapered photonic crystal fiber

    NASA Astrophysics Data System (ADS)

    Fu, Xing-hu; Xie, Hai-yang; Yang, Chuan-qing; Qu, Yu-wei; Zhang, Shun-yang; Fu, Guang-wei; Guo, Xuan; Bi, Wei-hong

    2016-05-01

    In this paper, a novel liquid refractive index (RI) sensor based on fused tapered photonic crystal fiber (PCF) is proposed. It is fabricated by fusing and tapering a section of PCF which is spliced with two single-mode fibers (SMFs). Due to the fused biconical taper method, the sensor becomes longer and thinner, to make the change of the outside RI has more direct effects on the internal optical field of the PCF, which finally enhances the sensitivity of this sensor. Experimental results show that the transmission spectra of the sensor are red-shifted obviously with the increase of RI. The longer the tapered region of the sensor, the higher the sensitivity is. This sensor has the advantages of simple structure, easy fabrication, high performance and so on, so it has potential applications in RI measurement.

  4. Stimulated Brillouin scattering in highly birefringent multimode tapered chalcogenide photonic crystal fiber for distributed optical sensors (Retraction Notice)

    NASA Astrophysics Data System (ADS)

    Baili, Amira; Cherif, Rim; Zghal, Mourad

    2016-09-01

    This paper, originally published on September 15, 2016, was retracted from the SPIE Digital Library on October 5, 2016, due to a high degree of similarity between specific portions of the text of the paper to the following publications: J. Tchahame, J. Beugnot, A. Kudlinski, and T. Sylvestre, "Multimode Brillouin spectrum in a long tapered birefringent photonic crystal fiber," Opt. Lett. 40, 4281-4284 (2015). doi: 10.1364/OL.40.004281 W. W. Ke, X. J. Wang and X. Tang, "Stimulated Brillouin Scattering Model in Multi-Mode Fiber Lasers," in IEEE Journal of Selected Topics in Quantum Electronics, vol. 20, no. 5, pp. 305-314, Sept.-Oct. 2014. doi: 10.1109/JSTQE.2014.2303256.

  5. Guided-Mode-Leaky-Mode-Guided-Mode Fiber Interferometer and Its High Sensitivity Refractive Index Sensing Technology.

    PubMed

    Wang, Qi; Li, Chunyue; Zhao, Chengwu; Li, Weizheng

    2016-06-01

    A cascaded symmetrical dual-taper Mach-Zehnder interferometer structure based on guided-mode and leaky-mode interference is proposed in this paper. Firstly, the interference spectrum characteristics of interferometer has been analyzed by the Finite Difference-Beam Propagation Method (FD-BPM). When the diameter of taper waist is 20 μm-30 μm, dual-taper length is 1 mm and taper distance is 4 cm-6 cm, the spectral contrast is higher, which is suitable for sensing. Secondly, experimental research on refractive index sensitivity is carried out. A refractive index sensitivity of 62.78 nm/RIU (refractive index unit) can achieved in the RI range of 1.3333-1.3792 (0%~25% NaCl solution), when the sensor structure parameters meet the following conditions: diameter of taper waist is 24 μm, dual-taper length is 837 μm and taper distance is 5.5 cm. The spectrum contrast is 0.8 and measurement resolution is 1.6 × 10(-5) RIU. The simulation analysis is highly consistent with experimental results. Research shows that the sensor has promising application in low RI fields where high-precision measurement is required due to its high sensitivity and stability.

  6. Exact finite element method analysis of viscoelastic tapered structures to transient loads

    NASA Technical Reports Server (NTRS)

    Spyrakos, Constantine Chris

    1987-01-01

    A general method is presented for determining the dynamic torsional/axial response of linear structures composed of either tapered bars or shafts to transient excitations. The method consists of formulating and solving the dynamic problem in the Laplace transform domain by the finite element method and obtaining the response by a numerical inversion of the transformed solution. The derivation of the torsional and axial stiffness matrices is based on the exact solution of the transformed governing equation of motion, and it consequently leads to the exact solution of the problem. The solution permits treatment of the most practical cases of linear tapered bars and shafts, and employs modeling of structures with only one element per member which reduces the number of degrees of freedom involved. The effects of external viscous or internal viscoelastic damping are also taken into account.

  7. Integrating pharmacogenomics into pharmacy practice via medication therapy management.

    PubMed

    Reiss, Susan M

    2011-01-01

    To explore the application and integration of pharmacogenomics in pharmacy clinical practice via medication therapy management (MTM) to improve patient care. Department of Health & Human Services (HHS) Personalized Health Care Initiative, Food and Drug Administration (FDA) pharmacogenomics activity, and findings from the Utilizing E-Prescribing Technologies to Integrate Pharmacogenomics into Prescribing and Dispensing Practices Stakeholder Workshop, convened by the American Pharmacists Association (APhA) on March 5, 2009. Participants at the Stakeholder Workshop included diverse representatives from pharmacy, medicine, pathology, health information technology (HIT), standards, science, academia, government, and others with a key interest in the clinical application of pharmacogenomics. In 2006, HHS initiated the Personalized Health Care Initiative with the goal of building the foundation for the delivery of gene-based care, which may prove to be more effective for large patient subpopulations. In the years since the initiative was launched, drug manufacturers and FDA have begun to incorporate pharmacogenomic data and applications of this information into the drug development, labeling, and approval processes. New applications and processes for using this emerging pharmacogenomics data are needed to effectively integrate this information into clinical practice. Building from the findings of a stakeholder workshop convened by APhA and the advancement of the pharmacist's collaborative role in patient care through MTM, emerging roles for pharmacists using pharmacogenomic information to improve patient care are taking hold. Realizing the potential role of the pharmacist in pharmacogenomics through MTM will require connectivity of pharmacists into the electronic health record infrastructure to permit the exchange of pertinent health information among all members of a patient's health care team. Addressing current barriers, concerns, and system limitations and developing an effective infrastructure will be necessary for pharmacogenomics to achieve its true potential. To achieve integration of pharmacogenomics into clinical practice via MTM, the pharmacy profession must define a process for the application of pharmacogenomic data into pharmacy clinical practice that is aligned with MTM service delivery, develop a viable business model for these practices, and encourage and direct the development of HIT solutions that support the pharmacist's role in this emerging field.

  8. Near millimeter wave imaging/multi-beam integrated antennas

    NASA Technical Reports Server (NTRS)

    Yngvesson, K. S.; Schaubert, D. H.

    1985-01-01

    This report describes the most recent work on the theory of single element Linearly Tapered Slot Antennas (LTSAs) and Constant Width Slot Antennas (CWSAs). The radiation mechanism for these is presently well understood and allows quantitative calculation of beamwidths and sidelobe levels, provided that the antennas have a sufficiently wide conducting region on either side of the tapered slot. Appendices 4 to 7 represent earlier work on the grant. This work further elucidates the properties of arrays of CWSA elements, and the effects of coupling on the beam-shape. It should be noted that typical beam-efficiencies of 65% have been estimated, and that element spacings of about one Rayleigh unit are possible. Further, two-point resolution at the Rayleigh spacing has been demonstrated for a CWSA array in a 30.4 cm paraboloid at 31 GHz. These results underscore that interest in further studies of the radiation mechanism of tapered slot arrays. Appendix 7 constitutes a final, detailed report on the work leading to a 94 GHz seven element LTSA array imaging system, which has been reported previously in less detail. Experimental results are presented.

  9. The cnm locus, a canine homologue of human autosomal forms of centronuclear myopathy, maps to chromosome 2.

    PubMed

    Tiret, Laurent; Blot, Stéphane; Kessler, Jean-Louis; Gaillot, Hugues; Breen, Matthew; Panthier, Jean-Jacques

    2003-09-01

    Myotubular/centronuclear myopathies are a nosological group of hereditary disorders characterised by severe architectural and metabolic remodelling of skeletal muscle fibres. In most myofibres, nuclei are found at an abnormal central position within a halo devoid of myofibrillar proteins. The X-linked form (myotubular myopathy) is the most prevalent and severe form in human, leading to death during early postnatal life. Maturation of fibres is not completed and fibres resemble myotubes. Linkage analysis in human has helped to identify MTM1 as the morbid gene. MTM1 encodes myotubularin, a dual protein phosphatase. In families in which myotubular myopathy segregates, detected mutations in MTM1 abolish the specific phosphatase activity targeting the second messenger phosphatidylinositol 3-phosphate. Autosomal forms (centronuclear) have a later onset and are often compatible with life. At birth, fibres are normally constituted but progressively follow remodelling with a secondary centralisation of nuclei. Their prevalence is low; hence, no linkage data can be performed and no molecular aetiology is known. In the Labrador Retriever, a spontaneous disorder strikingly mimics the clinical evolution of the human centronuclear myopathy. We have established a canine pedigree and show that the disorder segregates as an autosomal recessive trait in that pedigree. We have further mapped the dog locus to a region on chromosome 2 that is orthologous to human chromosome 10p. To date, no human MTM1 gene member has been mapped to this genetic region. This report thus describes the first spontaneous mammalian model of centronuclear myopathy and defines a new locus for this group of diseases.

  10. Development of a Selective Culture Medium for Primary Isolation of the Main Brucella Species▿

    PubMed Central

    De Miguel, M. J.; Marín, C. M.; Muñoz, P. M.; Dieste, L.; Grilló, M. J.; Blasco, J. M.

    2011-01-01

    Bacteriological diagnosis of brucellosis is performed by culturing animal samples directly on both Farrell medium (FM) and modified Thayer-Martin medium (mTM). However, despite inhibiting most contaminating microorganisms, FM also inhibits the growth of Brucella ovis and some B. melitensis and B. abortus strains. In contrast, mTM is adequate for growth of all Brucella species but only partially inhibitory for contaminants. Moreover, the performance of both culture media for isolating B. suis has never been established properly. We first determined the performance of both media for B. suis isolation, proving that FM significantly inhibits B. suis growth. We also determined the susceptibility of B. suis to the antibiotics contained in both selective media, proving that nalidixic acid and bacitracin are highly inhibitory, thus explaining the reduced performance of FM for B. suis isolation. Based on these results, a new selective medium (CITA) containing vancomycin, colistin, nystatin, nitrofurantoin, and amphotericin B was tested for isolation of the main Brucella species, including B. suis. CITA's performance was evaluated using reference contaminant strains but also field samples taken from brucella-infected animals or animals suspected of infection. CITA inhibited most contaminant microorganisms but allowed the growth of all Brucella species, to levels similar to those for both the control medium without antibiotics and mTM. Moreover, CITA medium was more sensitive than both mTM and FM for isolating all Brucella species from field samples. Altogether, these results demonstrate the adequate performance of CITA medium for the primary isolation of the main Brucella species, including B. suis. PMID:21270216

  11. TransitionRx: Impact of community pharmacy postdischarge medication therapy management on hospital readmission rate.

    PubMed

    Luder, Heidi R; Frede, Stacey M; Kirby, James A; Epplen, Kelly; Cavanaugh, Teresa; Martin-Boone, Jill E; Conrad, Wayne F; Kuhlmann, Diane; Heaton, Pamela C

    2015-01-01

    To determine if a community pharmacy-based transition of care (TOC) program that included the full scope of medication therapy management (MTM) services (TransitionRx) decreased hospital readmissions, resolved medication-related problems, and increased patient satisfaction. Prospective, quasi-experimental study. Nine Kroger Pharmacies located in Western Cincinnati. Patients older than 18 years of age and discharged from two local hospitals with a diagnosis of congestive heart failure, chronic obstructive pulmonary disease, or pneumonia. Patients were recruited from two local hospitals and referred to the community pharmacy for MTM services with the pharmacist within 1 week of discharge. Pharmacists reconciled the patients' medications, identified drug therapy problems, recommended changes to therapy, and provided self-management education. At 30 days after discharge, research personnel conducted telephone surveys, using a previously validated survey instrument, to assess hospital readmissions and patient satisfaction. Pharmacist interventions and medication-related problems were documented. A total of 90 patients completed the study. Of these, 20% of patients in the usual care group were admitted to the hospital within 30 days compared with 6.9% of patients in the intervention group (P = 0.019). In the 30 patients who received MTM services from the pharmacist, 210 interventions were made. The overall mean patient satisfaction with the TOC process was not significantly different between patients who were seen by the pharmacist and those who were not seen by the pharmacist. Community pharmacies successfully collaborated with hospitals to develop a referral process for TOC interventions. Patients who received MTM services from the pharmacist experienced significantly fewer readmissions than patients who received usual care.

  12. Dual Tuning of Ni-Co-A (A = P, Se, O) Nanosheets by Anion Substitution and Holey Engineering for Efficient Hydrogen Evolution.

    PubMed

    Fang, Zhiwei; Peng, Lele; Qian, Yumin; Zhang, Xiao; Xie, Yujun; Cha, Judy J; Yu, Guihua

    2018-04-18

    Seeking earth-abundant electrocatalysts with high efficiency and durability has become the frontier of energy conversion research. Mixed-transition-metal (MTM)-based electrocatalysts, owing to the desirable electrical conductivity, synergistic effect of bimetal atoms, and structural stability, have recently emerged as new-generation hydrogen evolution reaction (HER) electrocatalysts. However, the correlation between anion species and their intrinsic electrocatalytic properties in MTM-based electrocatalysts is still not well understood. Here we present a novel approach to tuning the anion-dependent electrocatalytic characteristics in MTM-based catalyst for HER, using holey Ni/Co-based phosphides/selenides/oxides (Ni-Co-A, A = P, Se, O) as the model materials. The electrochemical results, combined with the electrical conductivity measurement and DFT calculation, reveal that P substitution could modulate the electron configuration, lower the hydrogen adsorption energy, and facilitate the desorption of hydrogen on the active sites in Ni-Co-A holey nanostructures, resulting in superior HER catalytic activity. Accordingly we fabricate the NCP holey nanosheet electrocatalyst for HER with an ultralow onset overpotential of nearly zero, an overpotential of 58 mV, and long-term durability, along with an applied potential of 1.56 V to boost overall water splitting at 10 mA cm -2 , among the best electrocatalysts reported for non-noble-metal catalysts to date. This work not only presents a deeper understanding of the intrinsic HER electrocatalytic properties for MTM-based electrocatalyst with various anion species but also offers new insights to better design efficient and durable water-splitting electrocatalysts.

  13. Cost-benefit analysis of sequential warning lights in nighttime work zone tapers.

    DOT National Transportation Integrated Search

    2011-06-01

    Improving safety at nighttime work zones is important because of the extra visibility concerns. The deployment of sequential lights is an innovative method for improving driver recognition of lane closures and work zone tapers. Sequential lights are ...

  14. The seating mechanics of head-neck modular tapers in vitro: Load-displacement measurements, moisture, and rate effects.

    PubMed

    Ouellette, Eric S; Shenoy, Aarti A; Gilbert, Jeremy L

    2018-04-01

    The mechanically assisted crevice corrosion performance of head-neck modular tapers is a significant concern in orthopedic biomaterials. Fretting crevice corrosion processes in modular tapers are thought to be influenced by a wide array of factors including seating mechanics of the junction, hence there is a need for in vitro test methods that can assess their performance. This study presented a test method to directly measure the load-displacement seating mechanics of modular tapers and used this method to compare the seating mechanics for different tapers, moisture, seating loads and seating rates. Seating mechanics were explored whereby the instantaneous load-displacement behavior of the head seating onto the neck is captured and used to define the mechanics of seating. Two distinct taper design/material combinations were assembled wet or dry using axially applied loads (500, 1,000, 2,000, and 4,000 N) at two loading rates of 100 and 10 4  N/s (n = 5 for each condition) using a servohydraulic test frame. The results showed that pull-off strength scaled with seating load and ranged between 43% and 68% of seating load depending on sample and wetness. Tapers seated wet had higher pull-off strengths (2,200 ± 300 N) than those seated dry (1,800 ± 200 N, p < 0.05). Seating mechanics (load-displacement plots) varied due to sample type and due to wetness with differences in seating energy, seating stiffness, and seating displacement. These results show the detailed mechanics of seating during assembly and provide significant insight into the complex interplay of factors associated with even "ideal" seating (axial, quasistatic) loading. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1164-1172, 2018. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  15. Mechanics of the tapered interference fit in dental implants.

    PubMed

    Bozkaya, Dinçer; Müftü, Sinan

    2003-11-01

    In evaluation of the long-term success of a dental implant, the reliability and the stability of the implant-abutment interface plays a great role. Tapered interference fits provide a reliable connection method between the abutment and the implant. In this work, the mechanics of the tapered interference fits were analyzed using a closed-form formula and the finite element (FE) method. An analytical solution, which is used to predict the contact pressure in a straight interference, was modified to predict the contact pressure in the tapered implant-abutment interface. Elastic-plastic FE analysis was used to simulate the implant and abutment material behavior. The validity and the applicability of the analytical solution were investigated by comparisons with the FE model for a range of problem parameters. It was shown that the analytical solution could be used to determine the pull-out force and loosening-torque with 5-10% error. Detailed analysis of the stress distribution due to tapered interference fit, in a commercially available, abutment-implant system was carried out. This analysis shows that plastic deformation in the implant limits the increase in the pull-out force that would have been otherwise predicted by higher interference values.

  16. Resurgence of catatonia following tapering or stoppage of lorazepam - A case series and implications.

    PubMed

    Ali, Syed Farooq; Gowda, Guru S; Jaisoorya, T S; Math, Suresh Bada

    2017-08-01

    The resurgence of catatonia following tapering of lorazepam is a common clinical phenomenon. However, there is limited evidence on the relationship between tapering method of lorazepam and resurgence of catatonic state. We report seven (0.6%) such patients who were found to have resurgence of catatonia. The mean age is 35.7 years; five of them had schizophrenia and other psychotic spectrum disorders. Five of them had resurgence within one week of stoppage, and three of them had multiple resurgences and required maintenance treatment with lorazepam. So gradual tapering and maintenance treatment with lorazepam might be effective in preventing resurgence of catatonia. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Comparison of a new transport medium with universal transport medium at a tropical field site.

    PubMed

    Schlaudecker, Elizabeth P; Heck, Joan P; MacIntyre, Elizabeth T; Martinez, Ruben; Dodd, Caitlin N; McNeal, Monica M; Staat, Mary A; Heck, Jeffery E; Steinhoff, Mark C

    2014-10-01

    Limited data are available in rural Honduran settings describing the etiology of respiratory infections, partially due to limited specimen transport. A new molecular transport media (MTM) preserves released nucleic acid at ambient temperature for later detection. Prospective surveillance was conducted in a Honduran clinic to identify 233 children less than 5 years of age presenting with respiratory symptoms. We obtained 2 nasopharyngeal samples and stored 1 in PrimeStore® MTM at room temperature and 1 in universal transport media (UTM) at -80 °C. The specimens were then transported to Cincinnati Children's Hospital and tested for 16 respiratory viruses using a multiplex PCR panel. The 2 specimen collection systems were similar for detecting the 4 most common viruses: influenza (Kappa = 0.7676, P < 0.0001), human metapneumovirus (Kappa = 0.8770, P < 0.0001), respiratory syncytial virus (Kappa = 0.6849, P < 0.0001), and parainfluenza (Kappa = 0.8796, P < 0.0001). These results suggest that clinical specimens transported via PrimeStore® MTM and UTM yield similar viral multiplex PCR results. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Blood pressure kiosks for medication therapy management programs: business opportunity for pharmacists.

    PubMed

    Houle, Sherilyn K D; Chuck, Anderson W; Tsuyuki, Ross T

    2012-01-01

    To develop an economic model based on the use of pharmacy-based blood pressure kiosks for case finding of remunerable medication therapy management (MTM) opportunities. Descriptive, exploratory, nonexperimental study. Ontario, Canada, between January 2010 and September 2011. More than 7.5 million blood pressure kiosk readings were taken from 341 pharmacies. A model was developed to estimate revenues achievable by using blood pressure kiosks for 1 month to identify a cohort of patients with blood pressure of 130/80 mm Hg or more and caring for those patients during 1 year. Revenue generated from MTM programs. Pharmacies could generate an average of $12,270 (range $4,523-24,420) annually in revenue from billing for MTM services. Blood pressure kiosks can be used to identify patients with elevated blood pressure who may benefit from reimbursable pharmacist cognitive services. Revenue can be reinvested to purchase automated dispensing technology or offset pharmacy technician costs to free pharmacists to provide pharmaceutical care. Improved patient outcomes, increased patient loyalty, and improved adherence are additional potential benefits.

  19. Eigenvalue equation and core-mode cutoff of weakly guiding tapered fiber as three layer optical waveguide and used as biochemical sensor.

    PubMed

    Linslal, C L; Mohan, P M S; Halder, A; Gangopadhyay, T K

    2012-06-01

    The core-mode cutoff plays a major role in evanescent field absorption based sensors. A method has been proposed to calculate the core-mode cutoff by solving the eigenvalue equations of a weakly guiding three layer optical waveguide graphically. The variation of normalized waveguide parameter (V) is also calculated with different wavelengths at core-mode cutoff. At the first step, theoretical analysis of tapered fiber parameters has been performed for core-mode cutoff. The taper angle of an adiabatic tapered fiber is also analyzed using the length-scale criterion. Secondly, single-mode tapered fiber has been developed to make a precision sensor element suitable for chemical detection. Finally, the sensor element has been used to detect absorption peak of ethylenediamine. Results are presented in which an absorption peak at 1540 nm is observed.

  20. Octave-spanning supercontinuum generation in in situ tapered As₂S₃ fiber pumped by a thulium-doped fiber laser.

    PubMed

    Rudy, Charles W; Marandi, Alireza; Vodopyanov, Konstantin L; Byer, Robert L

    2013-08-01

    We report a supercontinuum spanning well over an octave of measurable bandwidth from about 1 to 3.7 μm in a 2.1 mm long As₂S₃ fiber taper using the in situ tapering method. A sub-100-fs mode-locked thulium-doped fiber laser system with ~300 pJ of pulse energy was used as the pump source. Third-harmonic generation was observed and currently limits the pump pulse energy and achievable spectral bandwidth.

  1. Efficacy of Tramadol Extended-Release for Opioid Withdrawal: A Randomized Clinical Trial.

    PubMed

    Dunn, Kelly E; Tompkins, D Andrew; Bigelow, George E; Strain, Eric C

    2017-09-01

    Opioid use disorder (OUD) is a significant public health problem. Supervised withdrawal (ie, detoxification) from opioids using clonidine or buprenorphine hydrochloride is a widely used treatment. To evaluate whether tramadol hydrochloride extended-release (ER), an approved analgesic with opioid and nonopioid mechanisms of action and low abuse potential, is effective for use in supervised withdrawal settings. A randomized clinical trial was conducted in a residential research setting with 103 participants with OUD. Participants' treatment was stabilized with morphine, 30 mg, administered subcutaneously 4 times daily. A 7-day taper using clonidine (n = 36), tramadol ER (n = 36), or buprenorphine (n = 31) was then instituted, and patients were crossed-over to double-blind placebo during a post-taper period. The study was conducted from October 25, 2010, to June 23, 2015. Retention, withdrawal symptom management, concomitant medication utilization, and naltrexone induction. Results were analyzed over time and using area under the curve for the intention-to-treat and completer groups. Of the 103 participants, 88 (85.4%) were men and 43 (41.7%) were white; mean (SD) age was 28.9 (10.4) years. Buprenorphine participants (28 [90.3%]) were significantly more likely to be retained at the end of the taper compared with clonidine participants (22 [61.1%]); tramadol ER retention was intermediate and did not differ significantly from that of the other groups (26 [72.2%]; χ2 = 8.5, P = .01). Time-course analyses of withdrawal revealed significant effects of phase (taper, post taper) for the Clinical Opiate Withdrawal Scale (COWS) score (taper mean, 5.19 [SE, .26]; post-taper mean, 3.97 [SE, .23]; F2,170 = 3.6, P = .03) and Subjective Opiate Withdrawal Scale (SOWS) score (taper mean,8.81 [SE, .40]; post-taper mean, 4.14 [SE, .30]; F2,170 = 15.7, P < .001), but no group effects or group × phase interactions. Analyses of area under the curve of SOWS total scores showed significant reductions (F2,159 = 17.7, P < .001) in withdrawal severity between the taper and post-taper periods for clonidine (taper mean, 13.1; post-taper mean, 3.2; P < .001) and tramadol ER (taper mean, 7.4; post-taper mean, 2.8; P = .03), but not buprenorphine (taper mean, 6.4; post-taper mean, 7.4). Use of concomitant medication increased significantly (F2,159 = 30.7,  P < .001) from stabilization to taper in the clonidine (stabilization mean, 0.64 [SE, .05]; taper mean, 1.54 [SE, .10]; P < .001) and tramadol ER (stabilization mean, 0.53 [SE, .05]; taper mean, 1.19 [SE, .09]; P = .003) groups and from stabilization to post taper in the buprenorphine group (stabilization mean, 0.46 [SE, .05] post-taper mean, 1.17 [SE, .09]; P = .006), suggesting higher withdrawal for those groups during those periods. Naltrexone initiation was voluntary and the percentage of participants choosing naltrexone therapy within the clonidine (8 [22.2%]), tramadol ER (7 [19.4%]), or buprenorphine (3 [9.7%]) groups did not differ significantly (χ2 = 2.5, P = .29). The results of this trial suggest that tramadol ER is more effective than clonidine and comparable to buprenorphine in reducing opioid withdrawal symptoms during a residential tapering program. Data support further examination of tramadol ER as a method to manage opioid withdrawal symptoms. Clinicaltrials.gov Identifier: NCT01188421.

  2. Towards a deterministic KPZ equation with fractional diffusion: the stationary problem

    NASA Astrophysics Data System (ADS)

    Abdellaoui, Boumediene; Peral, Ireneo

    2018-04-01

    In this work, we investigate by analysis the possibility of a solution to the fractional quasilinear problem: where is a bounded regular domain ( is sufficient), , 1  <  q and f is a measurable non-negative function with suitable hypotheses. The analysis is done separately in three cases: subcritical, 1  <  q  <  2s critical, q  =  2s and supercritical, q  >  2s. The authors were partially supported by Ministerio de Economia y Competitividad under grants MTM2013-40846-P and MTM2016-80474-P (Spain).

  3. Liquid-phase thermal diffusion isotope separation apparatus and method having tapered column

    DOEpatents

    Rutherford, William M.

    1988-05-24

    A thermal diffusion counterflow method and apparatus for separating isotopes in solution in which the solution is confined in a long, narrow, vertical slit which tapers from bottom to top. The variation in the width of the slit permits maintenance of a stable concentration distribution with relatively long columns, thus permitting isotopic separation superior to that obtainable in the prior art.

  4. Liquid-phase thermal diffusion isotope separation apparatus and method having tapered column

    DOEpatents

    Rutherford, W.M.

    1985-12-04

    A thermal diffusion counterflow method and apparatus for separating isotopes in solution in which the solution is confined in a long, narrow, vertical slit which tapers from bottom to top. The variation in the width of the slit permits maintenance of a stable concentration distribution with relatively long columns, thus permitting isotopic separation superior to that obtained in the prior art.

  5. Nonlinear Analysis of Bonded Composite Single-LAP Joints

    NASA Technical Reports Server (NTRS)

    Oterkus, E.; Barut, A.; Madenci, E.; Smeltzer, S. S.; Ambur, D. R.

    2004-01-01

    This study presents a semi-analytical solution method to analyze the geometrically nonlinear response of bonded composite single-lap joints with tapered adherend edges under uniaxial tension. The solution method provides the transverse shear and normal stresses in the adhesive and in-plane stress resultants and bending moments in the adherends. The method utilizes the principle of virtual work in conjunction with von Karman s nonlinear plate theory to model the adherends and the shear lag model to represent the kinematics of the thin adhesive layer between the adherends. Furthermore, the method accounts for the bilinear elastic material behavior of the adhesive while maintaining a linear stress-strain relationship in the adherends. In order to account for the stiffness changes due to thickness variation of the adherends along the tapered edges, their in-plane and bending stiffness matrices are varied as a function of thickness along the tapered region. The combination of these complexities results in a system of nonlinear governing equilibrium equations. This approach represents a computationally efficient alternative to finite element method. Comparisons are made with corresponding results obtained from finite-element analysis. The results confirm the validity of the solution method. The numerical results present the effects of taper angle, adherend overlap length, and the bilinear adhesive material on the stress fields in the adherends, as well as the adhesive, of a single-lap joint

  6. Guided-Mode-Leaky-Mode-Guided-Mode Fiber Interferometer and Its High Sensitivity Refractive Index Sensing Technology

    PubMed Central

    Wang, Qi; Li, Chunyue; Zhao, Chengwu; Li, Weizheng

    2016-01-01

    A cascaded symmetrical dual-taper Mach-Zehnder interferometer structure based on guided-mode and leaky-mode interference is proposed in this paper. Firstly, the interference spectrum characteristics of interferometer has been analyzed by the Finite Difference-Beam Propagation Method (FD-BPM). When the diameter of taper waist is 20 μm–30 μm, dual-taper length is 1 mm and taper distance is 4 cm–6 cm, the spectral contrast is higher, which is suitable for sensing. Secondly, experimental research on refractive index sensitivity is carried out. A refractive index sensitivity of 62.78 nm/RIU (refractive index unit) can achieved in the RI range of 1.3333–1.3792 (0%~25% NaCl solution), when the sensor structure parameters meet the following conditions: diameter of taper waist is 24 μm, dual-taper length is 837 μm and taper distance is 5.5 cm. The spectrum contrast is 0.8 and measurement resolution is 1.6 × 10−5 RIU. The simulation analysis is highly consistent with experimental results. Research shows that the sensor has promising application in low RI fields where high-precision measurement is required due to its high sensitivity and stability. PMID:27258281

  7. Effect of the tapered end of a FRP plate on the interfacial stresses in a strengthened beam used in civil engineering applications

    NASA Astrophysics Data System (ADS)

    Mahi, B. E.; Benrahou, K. H.; Belakhdar, Kh.; Tounsi, A.; Bedia, E. A. Adda

    2014-09-01

    The interfacial stresses of a beam strengthened with a FRP plate, which is widely employed in the civil engineering for rehabilitation and retrofitting of conventional structures, is investigated. An important feature of the reinforced beam is significant stress concentrations in the adhesive at the ends of the FRP plate. To reduce these interfacial stresses, a FRP plate with a tapered end is often used. The finite-difference method is utilized in this work to predict the distribution of interfacial stresses in beams strengthened with a FRP plate having a tapered end. Numerical results from the analysis are presented to demonstrate the advantages of using tapers in the design of strengthened beams.

  8. Yb3+-doped rod-type amplifiers with local adiabatic tapers for peak power scaling and beam quality improvement

    NASA Astrophysics Data System (ADS)

    Zhu, Yuan; Eschrich, Tina; Leich, Martin; Grimm, Stephan; Kobelke, Jens; Lorenz, Martin; Bartelt, Hartmut; Jäger, Matthias

    2017-10-01

    The use of short local tapers in large mode area fiber amplifiers is proposed for peak power scaling while maintaining good beam quality. To avoid modal distortions, the powder-sintering (REPUSIL) method was employed to obtain core materials with excellent refractive index homogeneity. First experiments with Yb3+-doped rod-type amplifiers delivered 2 ns pulses with peak powers of 540 kW and energies of 1.4 mJ for the untapered rod and 230 kW for the tapered rod (limited by facet damage). The beam quality improved from an M 2 value of approximately 10 to 3.5. The investigation of the taper structure indicates room for further improvement.

  9. Very low-loss passive fiber-to-chip coupling with tapered fibers.

    PubMed

    Paatzsch, T; Smaglinski, I; Abraham, M; Bauer, H D; Hempelmann, U; Neumann, G; Mrozynski, G; Kerndlmaier, W

    1997-07-20

    A novel passive fiber-to-chip coupling based on the use of fiber tapers embedded in a guiding structure is proposed. By beam-propagation calculations it is verified that this new coupling method exhibits a very low insertion loss. Major advantages of the proposed method compared with butt coupling are demonstrated by simulation results: first, tolerance requirements for the fibers, e.g., diameter variations and core eccentricity, and for fabrication of the alignment structure are reduced by at least 1 order of magnitude. Second, coupling to waveguides of nearly arbitrary dimensions and refractive indices seems to be possible. Experimental results on thermal drawing of fiber tapers are presented and used as input data for the simulations. A concept for fabrication of the new coupling method with the Lithographic Galvanik Abformung (LIGA) technique is presented.

  10. Quantitative evaluation of apically extruded debris during root canal instrumentation with ProTaper Universal, ProTaper Next, WaveOne, and self-adjusting file systems

    PubMed Central

    Ozsu, Damla; Karatas, Ertugrul; Arslan, Hakan; Topcu, Meltem C.

    2014-01-01

    Objectives: The aim of this study was to compare the amount of apically extruded debris during preparation with ProTaper Universal (Dentsply Maillefer, Ballaigues, Switzerland), ProTaper Next (Dentsply Maillefer), a reciprocating single-file (WaveOne; VDW GmbH, Munich, Germany), and a self-adjusting file (SAF; ReDent Nova, Ra’anna, Israel). Materials and Methods: Fifty-six intact mandibular premolar teeth were randomly assigned to four groups. The root canals were prepared according to the manufacturers’ instructions using the ProTaper Universal, ProTaper Next, WaveOne, and SAF. Apically extruded debris was collected in preweighted Eppendorf tubes during instrumentation. The net weight of the apically extruded debris was determined by subtracting the preweights and postweights of the tubes. The data were statistically analyzed using the one-way analysis of variance and the least significant difference tests at a significance level of P < 0.05. Results: A measurable amount of debris was apically extruded in all groups, and the amounts of debris extrusion in the groups were statistically significant (P < 0.001). The ProTaper Next and WaveOne groups resulted in less debris extrusion than the ProTaper Universal group (P < 0.05), and the SAF group resulted in the least debris extrusion. Conclusions: Within the limitations of the present study, it can be concluded that all systems extruded debris beyond the apical foramen. PMID:25512732

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fukuoka, T.

    Many studies have been devoted to investigate how the maximum stress occurring in the bolted joint could be reduced. Patterson and Kenny suggest that a modified nut with a straight bevel at the bearing surface is effective. However, they only dealt with M30, and estimations on the nut geometry had not been necessarily sufficient. In this study, an extensive finite element approach for solving general multi-body contact problem is proposed by incorporating a regularization method into stiffness matrices with singularity involved; thus, numerical analyses are executed to accurately determine the optimal shape of the modified nut for various design factors.more » A modified nut with a curved bevel is also treated, and it is concluded that the modified nuts are significantly effective for bolts with larger nominal diameter and fine pitch, and are practically useful compared to pitch modification and tapered thread methods.« less

  12. Comparative evaluation of dentinal crack formation after root canal preparation using ProTaper Next, OneShape, and Hyflex EDM

    PubMed Central

    Das, Sanjib; Pradhan, Prasanti Kumari; Lata, S.; Sinha, Sachidananda Prasad

    2018-01-01

    Introduction: The purpose of this study was to compare the incidence of dentinal crack formation after root canal preparation using ProTaper Next, OneShape, and Hyflex electrodischarge machining (HEDM). Materials and Methods: A total of 75 extracted mandibular premolars were selected. The root canals were instrumented using ProTaper Next, OneShape, and HEDM rotary files. All roots were horizontally sectioned at 3, 6, and 9 mm from apex with slow-speed saw under water cooling. The sections were observed under a stereomicroscope at ×25 to determine the absence or presence of crack. Data were analyzed using post hoc test and one-way ANOVA. Results: ProTaper Next and HEDM produced significantly less cracks than OneShape. Conclusion: Within the limitation of this in vitro study, it can be concluded that nickel–titanium instruments may cause cracks on the root surface. ProTaper Next and HEDM tend to produce less number of cracks as compared to OneShape. PMID:29674816

  13. Overmoded subterahertz surface wave oscillator with pure TM{sub 01} mode output

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Guangqiang; Zeng, Peng; Wang, Dongyang

    2016-02-15

    Overmoded O-type Cerenkov generators using annular electron beams are facing the problem of multi-modes output due to the inevitable structural discontinuities. A simple but effective method to achieve the pure TM{sub 01} mode output is applied on the 0.14 THz overmoded surface wave oscillator (SWO) in this paper. In spite of still using an overmoded slow wave structure to ensure the easy fabrication, the followed smooth circular waveguide is shrinkingly tapered to the output waveguide with appropriate radius that it cuts off other higher modes except TM{sub 01} mode. Moreover, the modified device here has the same power capacity as themore » previous one according to the numerical analysis. By optimized lengths of the transition waveguide and tapered waveguide, particle-in-cell simulation results indicate that the subterahertz wave with output power increased 14.2% at the same frequency is obtained from the proposed SWO under the previous input conditions, and importantly, the output power is all carried by TM{sub 01} mode as expected. Further simulation results in the pulse regime confirm the feasibility of the optimized structure in the actual experiments. This simple and viable design is also applicable to overmoded devices in the lower frequency band of subterahertz wave.« less

  14. Wild Plant Assessment for Heavy Metal Phytoremediation Potential along the Mafic and Ultramafic Terrain in Northern Pakistan

    PubMed Central

    Shah, Mohammad Tahir; Khan, Sardar; Saddique, Umar; Gul, Nida; Khan, Muhammad Usman; Malik, Riffat Naseem; Farooq, Muhammad; Naz, Alia

    2013-01-01

    This study investigates the wild plant species for their phytoremediation potential of macro and trace metals (MTM). For this purpose, soil and wild plant species samples were collected along mafic and ultramafic terrain in the Jijal, Dubair, and Alpuri areas of Kohistan region, northern Pakistan. These samples were analyzed for the concentrations of MTM (Na, K, Ca, Mg, Fe, Mn, Pb, Zn, Cd, Cu, Cr, Ni, and Co) using atomic absorption spectrometer (AAS-PEA-700). Soil showed significant (P < .001) contamination level, while plants had greater variability in metal uptake from the contaminated sites. Plant species such as Selaginella jacquemontii, Rumex hastatus, and Plectranthus rugosus showed multifold enrichment factor (EF) of Fe, Mn, Cr, Ni, and Co as compared to background area. Results revealed that these wild plant species have the ability to uptake and accumulate higher metals concentration. Therefore, these plant species may be used for phytoremediation of metals contaminated soil. However, higher MTM concentrations in the wild plant species could cause environmental hazards in the study area, as selected metals (Fe, Mn, Cr, Ni, Co, and Pb) have toxicological concerns. PMID:24078907

  15. Experimental Testing of a Metamaterial Slow Wave Structure for High-Power Microwave Generation

    NASA Astrophysics Data System (ADS)

    Shipman, K.; Prasad, S.; Andreev, D.; Fisher, D. M.; Reass, D. B.; Schamiloglu, E.; Gilmore, M.

    2017-10-01

    A high-power L band source has been developed using a metamaterial (MTM) to produce a double negative slow wave structure (SWS) for interaction with an electron beam. The beam is generated by a 700 kV, 6 kA short pulse (10 ns) accelerator. The design of the SWS consists of a cylindrical waveguide, loaded with alternating split-rings that are arrayed axially down the waveguide. The beam is guided down the center of the rings, where electrons interact with the MTM-SWS producing radiation. Power is extracted axially via a circular waveguide, and radiated by a horn antenna. Microwaves are characterized by an external detector placed in a waveguide. Mode characterization is performed using a neon bulb array. The bulbs are lit by the electric field, resulting in an excitation pattern that resembles the field pattern. This is imaged using an SLR camera. The MTM structure has electrically small features so breakdown is a concern. In addition to high speed cameras, a fiber-optic-fed, sub-ns photomultiplier tube array diagnostic has been developed and used to characterize breakdown light. Work supported by the Air Force Office of Scientific Research, MURI Grant FA9550-12-1-0489.

  16. Comparative study of material loss at the taper interface in retrieved metal-on-polyethylene and metal-on-metal femoral components from a single manufacturer.

    PubMed

    Bills, Paul; Racasan, Radu; Bhattacharya, Saugatta; Blunt, Liam; Isaac, Graham

    2017-08-01

    There have been a number of reports on the occurrence of taper corrosion and/or fretting and some have speculated on a link to the occurrence of adverse local tissue reaction specifically in relation to total hip replacement which have a metal-on-metal bearing. As such a study was carried out to compare the magnitude of material loss at the taper in a series of retrieved femoral heads used in metal-on-polyethylene bearings with that in a series of retrieved heads used in metal-on-metal bearings. A total of 36 metal-on-polyethylene and 21 metal-on-metal femoral components were included in the study all of which were received from a customer complaint database. Furthermore, a total of nine as-manufactured femoral components were included to provide a baseline for characterisation. All taper surfaces were assessed using an established corrosion scoring method and measurements were taken of the female taper surface using a contact profilometry. In the case of metal-on-metal components, the bearing wear was also assessed using coordinate metrology to determine whether or not there was a relationship between bearing and taper material loss in these cases. The study found that in this cohort the median value of metal-on-polyethylene taper loss was 1.25 mm 3 with the consequent median value for metal-on-metal taper loss being 1.75 mm 3 . This study also suggests that manufacturing form can result in an apparent loss of material from the taper surface determined to have a median value of 0.59 mm 3 . Therefore, it is clear that form variability is a significant confounding factor in the measurement of material loss from the tapers of femoral heads retrieved following revision surgery.

  17. Theoretical study on mode competition between fundamental and second harmonic modes in a 0.42 THz gyrotron with gradually tapered complex cavity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, Qixiang, E-mail: zxqi1105@gmail.com; Yu, Sheng; Zhang, Tianzhong

    2015-10-15

    In this paper, the nonlinear dynamics of mode competition in the complex cavity gyrotron are studied by using multi-frequency, time-dependent theory with the cold-cavity longitudinal profile approximation. Based on the theory, a code is written to simulate the mode competition in the gradually tapered complex cavity gyrotron operating at second harmonic oscillation. The simulations tracking seven competition modes show that single mode oscillation of the desired mode TE{sub 17.4} at 150 kW level can be expected with proper choice of operating parameters. Through studying on mode competition, it is proved that the complex cavity has a good capability for suppressing themore » mode competition. Meanwhile, it is found that TE{sub 17.3} could be excited in the first cavity as a competition mode when the gyrotron operating at large beam current, which leads to that TE{sub 17.3} and TE{sub 17.4} with different frequencies can coexist stably in the complex cavity gyrotron with very close amplitudes. Thus, the complex cavity might be used for multi-frequency output gyrotron.« less

  18. Comparative study of ProTaper gold, reciproc, and ProTaper universal for root canal preparation in severely curved root canals

    PubMed Central

    Arslan, Hakan; Yildiz, Ezgi Doganay; Gunduz, Hicran Ates; Sumbullu, Meltem; Bayrakdar, Ibrahim Sevki; Karatas, Ertugrul; Sumbullu, Muhammed Akif

    2017-01-01

    Aim: The aim of this study is to evaluate the root canal transportation, centering ability, and instrumentation times with the ProTaper Gold (Dentsply Tulsa Dental, Tulsa, OK, USA), Reciproc (VDW, Munich, Germany), and ProTaper Universal (Dentsply Maillefer, Ballaigues, Switzerland) using cone-beam computed tomography (CBCT). Materials and Methods: Thirty mesial root canals of mandibular first molars with curvature angles of 35°–70° and radii of 2–6 mm were included in the study. Root canal instrumentation was performed up to F2 or R25. The instrumentation times were recorded. CBCT scanning was performed both pre- and post-instrumentation. Root canal transportation and the centering ratio were calculated for groups, and the data were analyzed using a one-way ANOVA and least significant difference post hoc tests for the instrumentation time, root canal transportation, and centering ratio at the 95% confidence level (P = 0.05). Results: At 3, 5, and 7 mm levels, there was no significant difference in the root canal transportation and centering ratio among the groups (P > 0.05). There were significant differences between the Reciproc and ProTaper Universal groups in the instrumentation times (P < 0.05). Conclusion: Root canal transportation and the centering ratio with the ProTaper Gold were similar to those obtained with the ProTaper Universal and Reciproc. PMID:29259355

  19. Steering of aggregating magnetic microparticles using propulsion gradients coils in an MRI Scanner.

    PubMed

    Mathieu, Jean-Baptiste; Martel, Sylvain

    2010-05-01

    Upgraded gradient coils can effectively enhance the MRI steering of magnetic microparticles in a branching channel. Applications of this method include MRI targeting of magnetic embolization agents for oncologic therapy. A magnetic suspension of Fe(3)O(4) magnetic particles was injected inside a y-shaped microfluidic channel. Magnetic gradients of 0, 50, 100, 200, and 400 mT/m were applied to the magnetic particles perpendicularly to the flow by a custom-built gradient coil inside a 1.5-T MRI scanner. Measurement of the steering ratio was performed both by video analyses and quantification of the mass of the particles collected at each outlet of the microfluidic channel, using atomic absorption spectroscopy. Magnetic particles steering ratios of 0.99 and 0.75 were reached with 400 mT/m gradient amplitude and measured by video analyses and atomic absorption spectroscopy, respectively. Experimental data shows that the steering ratio increases with higher magnetic gradients. Moreover, theory suggests that larger particles (or aggregates), higher magnetizations, and lower flows can also be used to improve the steering ratio. The technological limitation of the approach is that an MRI gradient amplitude increase to a few hundred milliteslas per meter is needed. A simple analytical method based on magnetophoretic velocity predictions and geometric considerations is proposed for steering ratio calculation. (c) 2010 Wiley-Liss, Inc.

  20. Do Stem Taper Microgrooves Influence Taper Corrosion in Total Hip Arthroplasty? A Matched Cohort Retrieval Study.

    PubMed

    Arnholt, Christina M; MacDonald, Daniel W; Underwood, Richard J; Guyer, Eric P; Rimnac, Clare M; Kurtz, Steven M; Mont, Michael A; Klein, Gregg R; Lee, Gwo-Chin; Chen, Antonia F; Hamlin, Brian R; Cates, Harold E; Malkani, Arthur L; Kraay, Matthew J

    2017-04-01

    Previous studies identified imprinting of the stem morphology onto the interior head bore, leading researchers to hypothesize an influence of taper topography on mechanically assisted crevice corrosion. The purpose of this study was to analyze whether microgrooved stem tapers result in greater fretting corrosion damage than smooth stem tapers. A matched cohort of 120 retrieved head-stem pairs from metal-on-polyethylene bearings was created controlling for implantation time, flexural rigidity, apparent length of engagement, and head size. There were 2 groups of 60 heads each, mated with either smooth or microgrooved stem tapers. A high-precision roundness machine was used to measure and categorize the surface morphology. Fretting corrosion damage at the head-neck junction was characterized using the Higgs-Goldberg scoring method. Fourteen of the most damaged heads were analyzed for the maximum depth of material loss and focused ion beam cross-sectioned to view oxide and base metal. Fretting corrosion damage was not different between the 2 cohorts at the femoral head (P = .14, Mann-Whitney) or stem tapers (P = .35). There was no difference in the maximum depths of material loss between the cohorts (P = .71). Cross-sectioning revealed contact damage, signs of micro-motion, and chromium-rich oxide layers in both cohorts. Microgroove imprinting did not appear to have a different effect on the fretting corrosion behavior. The results of this matched cohort retrieval study do not support the hypothesis that taper surfaces with microgrooved stems exhibit increased in vivo fretting corrosion damage or material release. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Adiabatically tapered microstructured mode converter for selective excitation of the fundamental mode in a few mode fiber.

    PubMed

    Taher, Aymen Belhadj; Di Bin, Philippe; Bahloul, Faouzi; Tartaret-Josnière, Etienne; Jossent, Mathieu; Février, Sébastien; Attia, Rabah

    2016-01-25

    We propose a new technique to selectively excite the fundamental mode in a few mode fiber (FMF). This method of excitation is made from a single mode fiber (SMF) which is inserted facing the FMF into an air-silica microstructured cane before the assembly is adiabatically tapered. We study theoretically and numerically this method by calculating the effective indices of the propagated modes, their amplitudes along the taper and the adiabaticity criteria, showing the ability to achieve an excellent selective excitation of the fundamental mode in the FMF with negligible loss. We experimentally demonstrate that the proposed solution provides a successful mode conversion and allows an almost excellent fundamental mode excitation in the FMF (representing 99.8% of the total power).

  2. Design optimization and tolerance analysis of a spot-size converter for the taper-assisted vertical integration platform in InP.

    PubMed

    Tolstikhin, Valery; Saeidi, Shayan; Dolgaleva, Ksenia

    2018-05-01

    We report on the design optimization and tolerance analysis of a multistep lateral-taper spot-size converter based on indium phosphide (InP), performed using the Monte Carlo method. Being a natural fit to (and a key building block of) the regrowth-free taper-assisted vertical integration platform, such a spot-size converter enables efficient and displacement-tolerant fiber coupling to InP-based photonic integrated circuits at a wavelength of 1.31 μm. An exemplary four-step lateral-taper design featuring 0.35 dB coupling loss at optimal alignment of a standard single-mode fiber; ≥7  μm 1 dB displacement tolerance in any direction in a facet plane; and great stability against manufacturing variances is demonstrated.

  3. Improving the economic and humanistic outcomes for diabetic patients: making a case for employer-sponsored medication therapy management

    PubMed Central

    Pinto, Sharrel L; Kumar, Jinender; Partha, Gautam; Bechtol, Robert A

    2013-01-01

    Background The purpose of this study was to determine the cost savings of a pharmacist-led, employer-sponsored medication therapy management (MTM) program for diabetic patients and to assess for any changes in patient satisfaction and self-reported medication adherence for enrollees. Methods Participants in this study were enrollees of an employer-sponsored MTM program. They were included if their primary medical insurance and prescription coverage was from the City of Toledo, they had a diagnosis of type 2 diabetes, and whether or not they had been on medication or had been given a new prescription for diabetes treatment. The data were analyzed on a prospective, pre-post longitudinal basis, and tracked for one year following enrollment. Outcomes included economic costs, patient satisfaction, and self-reported patient adherence. Descriptive statistics were used to characterize the population, calculate the number of visits, and determine the mean costs for each visit. Friedman’s test was used to determine changes in outcomes due to the nonparametric nature of the data. Results The mean number of visits to a physician’s office decreased from 10.22 to 7.07. The mean cost of these visits for patients increased from $47.70 to $66.41, but use of the emergency room and inpatient visits decreased by at least 50%. Employer spending on emergency room visits decreased by $24,214.17 and inpatient visit costs decreased by $166,610.84. Office visit spending increased by $11,776.41. A total cost savings of $179,047.80 was realized by the employer at the end of the program. Significant improvements in patient satisfaction and adherence were observed. Conclusion Pharmacist interventions provided through the employer-sponsored MTM program led to substantial cost savings to the employer with improved patient satisfaction and adherence on the part of employees at the conclusion of the program. PMID:23610526

  4. Controlling coarse woody debris inventory quality: taper and relative size methods

    Treesearch

    C.W. Woodall; J.A. Westfall

    2008-01-01

    Accurately measuring the dimensions of coarse woody debris (CWD) is critical for ensuring the quality of CWD estimates and, hence, for accurately estimating forest ecosystem attributes (e.g., CWD carbon stocks). To improve the quality of CWD dimensional measurements, the distribution of taper (ratio of change in diameter and length) and relative size (RS; ratio of...

  5. Design and performance of tapered cubic anvil used for achieving higher pressure and larger sample cell

    NASA Astrophysics Data System (ADS)

    Han, Qi-Gang; Yang, Wen-Ke; Zhu, Pin-Wen; Ban, Qing-Chu; Yan, Ni; Zhang, Qiang

    2013-07-01

    In order to increase the maximum cell pressure of the cubic high pressure apparatus, we have developed a new structure of tungsten carbide cubic anvil (tapered cubic anvil), based on the principle of massive support and lateral support. Our results indicated that the tapered cubic anvil has some advantages. First, tapered cubic anvil can push the transfer rate of pressure well into the range above 36.37% compare to the conventional anvil. Second, the rate of failure crack decreases about 11.20% after the modification of the conventional anvil. Third, the limit of static high-pressure in the sample cell can be extended to 13 GPa, which can increase the maximum cell pressure about 73.3% than that of the conventional anvil. Fourth, the volume of sample cell compressed by tapered cubic anvils can be achieved to 14.13 mm3 (3 mm diameter × 2 mm long), which is three and six orders of magnitude larger than that of double-stage apparatus and diamond anvil cell, respectively. This work represents a relatively simple method for achieving higher pressures and larger sample cell.

  6. A sensitivity-enhanced refractive index sensor using a single-mode thin-core fiber incorporating an abrupt taper.

    PubMed

    Shi, Jie; Xiao, Shilin; Yi, Lilin; Bi, Meihua

    2012-01-01

    A sensitivity-enhanced fiber-optic refractive index (RI) sensor based on a tapered single-mode thin-core diameter fiber is proposed and experimentally demonstrated. The sensor head is formed by splicing a section of tapered thin-core diameter fiber (TCF) between two sections of single-mode fibers (SMFs). The cladding modes are excited at the first SMF-TCF interface, and then interfere with the core mode at the second interface, thus forming an inter-modal interferometer (IMI). An abrupt taper (tens of micrometers long) made by the electric-arc-heating method is utilized, and plays an important role in improving sensing sensitivity. The whole manufacture process only involves fiber splicing and tapering, and all the fabrication process can be achieved by a commercial fiber fusion splicer. Using glycerol and water mixture solution as an example, the experimental results show that the refractive index sensitivity is measured to be 0.591 nm for 1% change of surrounding RI. The proposed sensor structure features simple structure, low cost, easy fabrication, and high sensitivity.

  7. Modeling of dispersion and nonlinear characteristics of tapered photonic crystal fibers for applications in nonlinear optics

    NASA Astrophysics Data System (ADS)

    Pakarzadeh, H.; Rezaei, S. M.

    2016-01-01

    In this article, we investigate for the first time the dispersion and the nonlinear characteristics of the tapered photonic crystal fibers (PCFs) as a function of length z, via solving the eigenvalue equation of the guided mode using the finite-difference frequency-domain method. Since the structural parameters such as the air-hole diameter and the pitch of the microstructured cladding change along the tapered PCFs, dispersion and nonlinear properties change with the length as well. Therefore, it is important to know the exact behavior of such fiber parameters along z which is necessary for nonlinear optics applications. We simulate the z dependency of the zero-dispersion wavelength, dispersion slope, effective mode area, nonlinear parameter, and the confinement loss along the tapered PCFs and propose useful relations for describing dispersion and nonlinear parameters. The results of this article, which are in a very good agreement with the available experimental data, are important for simulating pulse propagation as well as investigating nonlinear effects such as supercontinuum generation and parametric amplification in tapered PCFs.

  8. Vibration sensitivity of the scanning near-field optical microscope with a tapered optical fiber probe.

    PubMed

    Chang, Win-Jin; Fang, Te-Hua; Lee, Haw-Long; Yang, Yu-Ching

    2005-01-01

    In this paper the Rayleigh-Ritz method was used to study the scanning near-field optical microscope (SNOM) with a tapered optical fiber probe's flexural and axial sensitivity to vibration. Not only the contact stiffness but also the geometric parameters of the probe can influence the flexural and axial sensitivity to vibration. According to the analysis, the lateral and axial contact stiffness had a significant effect on the sensitivity of vibration of the SNOM's probe, each mode had a different level of sensitivity and in the first mode the tapered optical fiber probe was the most acceptive to higher levels of flexural and axial vibration. Generally, when the contact stiffness was lower, the tapered probe was more sensitive to higher levels of both axial and flexural vibration than the uniform probe. However, the situation was reversed when the contact stiffness was larger. Furthermore, the effect that the probe's length and its tapered angle had on the SNOM's probe axial and flexural vibration were significant and these two conditions should be incorporated into the design of new SNOM probes.

  9. Tuning micropillar tapering for optimal friction performance of thermoplastic gecko-inspired adhesive.

    PubMed

    Kim, Yongkwan; Chung, Yunsie; Tsao, Angela; Maboudian, Roya

    2014-05-14

    We present a fabrication method and friction testing of a gecko-inspired thermoplastic micropillar array with control over the tapering angle of the pillar sidewall. A combination of deep reactive ion etching of vertical silicon pillars and subsequent maskless chemical etching produces templates with various widths and degrees of taper, which are then replicated with low-density polyethylene. As the silicon pillars on the template are chemically etched in a bath consisting of hydrofluoric acid, nitric acid, and acetic acid (HNA), the pillars are progressively thinned, then shortened. The replicated polyethylene pillar arrays exhibit a corresponding increase in friction as the stiffness is reduced with thinning and then a decrease in friction as the stiffness is again increased. The dilution of the HNA bath in water influences the tapering angle of the silicon pillars. The friction of the replicated pillars is maximized for the taper angle that maximizes the contact area at the tip which in turn is influenced by the stiffness of the tapered pillars. To provide insights on how changes in microscale geometry and contact behavior may affect friction of the pillar array, the pillars are imaged by scanning electron microscopy after friction testing, and the observed deformation behavior from shearing is related to the magnitude of the macroscale friction values. It is shown that the tapering angle critically changes the pillar compliance and the available contact area. Simple finite element modeling calculations are performed to support that the observed deformation is consistent with what is expected from a mechanical analysis. We conclude that friction can be maximized via proper pillar tapering with low stiffness that still maintains enough contact area to ensure high adhesion.

  10. Development and First Results of the Width-Tapered Beam Method for Adhesion Testing of Photovoltaic Material Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bosco, Nick; Tracy, Jared; Dauskardt, Reinhold

    2016-11-21

    A fracture mechanics based approach for quantifying adhesion at every interface within the PV module laminate is presented. The common requirements of monitoring crack length and specimen compliance are circumvented through development of a width-tapered cantilever beam method. This technique may be applied at both the module and coupon level to yield a similar, quantitative, measurement. Details of module and sample preparation are described and first results on field-exposed modules deployed for over 27 years presented.

  11. Cone-beam Computed Tomography Evaluation of Root Canal Preparation using Various Rotary Instruments: An in vitro Study.

    PubMed

    Ramanathan, Suhashini; Solete, Pradeep

    2015-11-01

    To evaluate the remaining dentin thickness of teeth after cleaning and shaping the root canal using three rotary instrumentation technique using cone-beam computed tomography (CBCT). This in vitro study is being done with 30 premolar samples with 20' curvature. The study is divided into three groups a CBCT was taken to measure the shortest distance from the root canal outline to the closest adjacent root surface was measured at each level from the cementoenamel junction (CEJ) (1,3, 5 and 7 mm) before and after root canal instrumentation. The purpose of this study was to compare the effects of different instruments used to prepare curved root canals on the remaining cervical dentin thickness and total amount of dentin removed from root canals during instrumentation by using multi-slice CBCT. The remaining dentin thickness is very much necessary for the success rate of root canal treatment. However, this study helps to prove that a conservative preparation with a sound remaining dentin thickness is much more advisable. It was observed that there was a significant difference at 1 and 3 mm (p < 0.05) and at 5 and 7 mm there was no significant difference ( p > 0.05). Mtwo has removed less amount dentin when compared to ProTaper Universal and ProTaper Next system at 1 and 3 mm. Under the conditions of the study, we concluded that ProTaper Universal and ProTaper Next should be used judiciously, as it causes higher thinning of root dentin of the root when compared with Mtwo.

  12. Coherent combining of high brightness tapered lasers in master oscillator power amplifier configuration

    NASA Astrophysics Data System (ADS)

    Albrodt, P.; Hanna, M.; Moron, F.; Decker, J.; Winterfeldt, M.; Blume, G.; Erbert, G.; Crump, P.; Georges, P.; Lucas-Leclin, G.

    2018-02-01

    Improved diode laser beam combining techniques are in strong demand for applications in material processing. Coherent beam combining (CBC) is the only combining approach that has the potential to maintain or even improve all laser properties, and thus has high potential for future systems. As part of our ongoing studies into CBC of diode lasers, we present recent progress in the coherent superposition of high-power single-pass tapered laser amplifiers. The amplifiers are seeded by a DFB laser at λ = 976 nm, where the seed is injected into a laterally single-mode ridge-waveguide input section. The phase pistons on each beam are actively controlled by varying the current in the ridge section of each amplifier, using a sequential hill-climbing algorithm, resulting in a combined beam with power fluctuations of below 1%. The currents into the tapered sections of the amplifiers are separately controlled, and remain constant. In contrast to our previous studies, we favour a limited number of individual high-power amplifiers, in order to preserve a high extracted power per emitter in a simple, low-loss coupling arrangement. Specifically, a multi-arm interferometer architecture with only three devices is used, constructed using 6 mm-long tapered amplifiers, mounted junction up on C-mounts, to allow separate contact to single mode and amplifier sections. A maximum coherently combined power of 12.9 W is demonstrated in a nearly diffraction-limited beam, corresponding to a 65% combining efficiency, with power mainly limited by the intrinsic beam quality of the amplifiers. Further increased combined power is currently sought.

  13. Use of manometric temperature measurement (MTM) and SMART freeze dryer technology for development of an optimized freeze-drying cycle.

    PubMed

    Gieseler, Henning; Kramer, Tony; Pikal, Michael J

    2007-12-01

    This report provides, for the first time, a summary of experiments using SMART Freeze Dryer technology during a 9 month testing period. A minimum ice sublimation area of about 300 cm(2) for the laboratory freeze dryer, with a chamber volume 107.5 L, was found consistent with data obtained during previous experiments with a smaller freeze dryer (52 L). Good reproducibility was found for cycle design with different type of excipients, formulations, and vials used. SMART primary drying end point estimates were accurate in the majority of the experiments, but showed an over prediction of primary cycle time when the product did not fully achieve steady state conditions before the first MTM measurement was performed. Product resistance data for 5% sucrose mixtures at varying fill depths were very reproducible. Product temperature determined by SMART was typically in good agreement with thermocouple data through about 50% of primary drying time, with significant deviations occurring near the end of primary drying, as expected, but showing a bias much earlier in primary drying for high solid content formulations (16.6% Pfizer product) and polyvinylpyrrolidone (40 kDa) likely due to water "re-adsorption" by the amorphous product during the MTM test. (c) 2007 Wiley-Liss, Inc.

  14. Systemic AAV8-Mediated Gene Therapy Drives Whole-Body Correction of Myotubular Myopathy in Dogs.

    PubMed

    Mack, David L; Poulard, Karine; Goddard, Melissa A; Latournerie, Virginie; Snyder, Jessica M; Grange, Robert W; Elverman, Matthew R; Denard, Jérôme; Veron, Philippe; Buscara, Laurine; Le Bec, Christine; Hogrel, Jean-Yves; Brezovec, Annie G; Meng, Hui; Yang, Lin; Liu, Fujun; O'Callaghan, Michael; Gopal, Nikhil; Kelly, Valerie E; Smith, Barbara K; Strande, Jennifer L; Mavilio, Fulvio; Beggs, Alan H; Mingozzi, Federico; Lawlor, Michael W; Buj-Bello, Ana; Childers, Martin K

    2017-04-05

    X-linked myotubular myopathy (XLMTM) results from MTM1 gene mutations and myotubularin deficiency. Most XLMTM patients develop severe muscle weakness leading to respiratory failure and death, typically within 2 years of age. Our objective was to evaluate the efficacy and safety of systemic gene therapy in the p.N155K canine model of XLMTM by performing a dose escalation study. A recombinant adeno-associated virus serotype 8 (rAAV8) vector expressing canine myotubularin (cMTM1) under the muscle-specific desmin promoter (rAAV8-cMTM1) was administered by simple peripheral venous infusion in XLMTM dogs at 10 weeks of age, when signs of the disease are already present. A comprehensive analysis of survival, limb strength, gait, respiratory function, neurological assessment, histology, vector biodistribution, transgene expression, and immune response was performed over a 9-month study period. Results indicate that systemic gene therapy was well tolerated, prolonged lifespan, and corrected the skeletal musculature throughout the body in a dose-dependent manner, defining an efficacious dose in this large-animal model of the disease. These results support the development of gene therapy clinical trials for XLMTM. Copyright © 2017 The American Society of Gene and Cell Therapy. Published by Elsevier Inc. All rights reserved.

  15. The Effects of Mountaintop Mines and Valley Fills on Aquatic ...

    EPA Pesticide Factsheets

    This report assesses the state of the science on the environmental impacts of mountaintop mines and valley fills (MTM-VF) on streams in the Central Appalachian Coalfields. Our review focused on the aquatic impacts of mountaintop removal coal mining, which, as its name suggests, involves removing all or some portion of the top of a mountain or ridge to expose and mine one or more coal seams. The excess overburden is disposed of in constructed fills in small valleys or hollows adjacent to the mining site. MTM-VF lead directly to five principal alterations of stream ecosystems: (1) springs, intermittent streams, and small perennial streams are permanently lost with the removal of the mountain and from burial under fill, (2) concentrations of major chemical ions are persistently elevated downstream, (3) degraded water quality reaches levels that are acutely lethal to standard laboratory test organisms, (4) selenium concentrations are elevated, reaching concentrations that have caused toxic effects in fish and birds and (5) macroinvertebrate and fish communities are consistently and significantly degraded. This report assesses the state of the science on the environmental impacts of Mountaintop Mines and Valley Fills (MTM-VF) on streams in the Central Appalachian Coalfields. The draft report will be externally peer reviewed by EPA's Science Advisory Board in early 2010.

  16. High-brightness tapered laser diodes with photonic crystal structures

    NASA Astrophysics Data System (ADS)

    Li, Yi; Du, Weichuan; Kun, Zhou; Gao, Songxin; Ma, Yi; Tang, Chun

    2018-02-01

    Beam quality of tapered laser diodes is limited by higher order lateral mode. On purpose of optimizing the brightness of tapered laser diodes, we developed a novel design of tapered diodes. This devices based on InGaAs/AlGaAs asymmetry epitaxial structure, containing higher order lateral mode filtering schemes especially photonic crystal structures, which fabricated cost effectively by using standard photolithography and dry etch processes. Meanwhile, the effects of photonic crystal structures on mode control are also investigated theoretically by FDBPM (Finite-Difference Beam Propagation Method) calculation. We achieved a CW optical output power of 6.9W at 940nm for a single emitter with 4 mm cavity length. A nearly diffraction limited beam of M2 ≍1.9 @ 0.5W has been demonstrated, and a highest brightness of β =75MW/(cm2 ·sr) was reached.

  17. An efficient method for supercontinuum generation in dispersion-tailored Lead-silicate fiber taper

    NASA Astrophysics Data System (ADS)

    Chen, Z.; Ma, S.; Dutta, N. K.

    2010-08-01

    In this paper we theoretically study the broadband mid-IR supercontinuum generation (SCG) in a lead-silicate microstructured fiber (the glass for simulation is SF57). The total dispersion of the fiber can be tailored by changing the core diameter of the fiber so that dispersion profiles with two zero dispersion wavelengths (ZDWs) can be obtained. Numerical simulations of the SCG process in a 4 cm long SF57 fiber/fiber taper seeded by femto-second pulses at telecommunications wavelength of 1.55 µm are presented. The results show that a fiber taper features a continuous shift of the longer zero dispersion wavelength. This extends the generated continuum to a longer wavelength region compared to fibers with fixed ZDWs. The phase-matching condition (PMC) is continuously modified in the fiber taper and the bandwidth of the generated dispersive waves (DWs) is significantly broadened.

  18. Coupling Single-Mode Fiber to Uniform and Symmetrically Tapered Thin-Film Waveguide Structures Using Gadolinium Gallium Garnet

    NASA Technical Reports Server (NTRS)

    Gadi, Jagannath; Yalamanchili, Raj; Shahid, Mohammad

    1995-01-01

    The need for high efficiency components has grown significantly due to the expanding role of fiber optic communications for various applications. Integrated optics is in a state of metamorphosis and there are many problems awaiting solutions. One of the main problems being the lack of a simple and efficient method of coupling single-mode fibers to thin-film devices for integrated optics. In this paper, optical coupling between a single-mode fiber and a uniform and tapered thin-film waveguide is theoretically modeled and analyzed. A novel tapered structure presented in this paper is shown to produce perfect match for power transfer.

  19. Low-loss deposition of solgel-derived silica films on tapered fibers.

    PubMed

    Kakarantzas, G; Leon-Saval, S G; Birks, T A; Russell, P St J

    2004-04-01

    Films of porous silica are deposited on the uniform waists of tapered fibers in minutes by a modified solgel dip coating method, inducing less than 0.2 dB of loss. The coated tapers are an ideal platform for realizing all-fiber devices that exploit evanescent-field interactions with the deposited porous film. As an example we demonstrate structural long-period gratings in which a periodic index variation in the film arises from the porosity variation produced by spatially varying exposure of the waist to a scanned CO2 laser beam. The long period grating is insensitive to temperature up to 800 degrees C.

  20. Association of Climatic Variability, Vector Population and Malarial Disease in District of Visakhapatnam, India: A Modeling and Prediction Analysis.

    PubMed

    Srimath-Tirumula-Peddinti, Ravi Chandra Pavan Kumar; Neelapu, Nageswara Rao Reddy; Sidagam, Naresh

    2015-01-01

    Malarial incidence, severity, dynamics and distribution of malaria are strongly determined by climatic factors, i.e., temperature, precipitation, and relative humidity. The objectives of the current study were to analyse and model the relationships among climate, vector and malaria disease in district of Visakhapatnam, India to understand malaria transmission mechanism (MTM). Epidemiological, vector and climate data were analysed for the years 2005 to 2011 in Visakhapatnam to understand the magnitude, trends and seasonal patterns of the malarial disease. Statistical software MINITAB ver. 14 was used for performing correlation, linear and multiple regression analysis. Perennial malaria disease incidence and mosquito population was observed in the district of Visakhapatnam with peaks in seasons. All the climatic variables have a significant influence on disease incidence as well as on mosquito populations. Correlation coefficient analysis, seasonal index and seasonal analysis demonstrated significant relationships among climatic factors, mosquito population and malaria disease incidence in the district of Visakhapatnam, India. Multiple regression and ARIMA (I) models are best suited models for modeling and prediction of disease incidences and mosquito population. Predicted values of average temperature, mosquito population and malarial cases increased along with the year. Developed MTM algorithm observed a major MTM cycle following the June to August rains and occurring between June to September and minor MTM cycles following March to April rains and occurring between March to April in the district of Visakhapatnam. Fluctuations in climatic factors favored an increase in mosquito populations and thereby increasing the number of malarial cases. Rainfall, temperatures (20°C to 33°C) and humidity (66% to 81%) maintained a warmer, wetter climate for mosquito growth, parasite development and malaria transmission. Changes in climatic factors influence malaria directly by modifying the behaviour and geographical distribution of vectors and by changing the length of the life cycle of the parasite.

  1. Association of Climatic Variability, Vector Population and Malarial Disease in District of Visakhapatnam, India: A Modeling and Prediction Analysis

    PubMed Central

    Srimath-Tirumula-Peddinti, Ravi Chandra Pavan Kumar; Neelapu, Nageswara Rao Reddy; Sidagam, Naresh

    2015-01-01

    Background Malarial incidence, severity, dynamics and distribution of malaria are strongly determined by climatic factors, i.e., temperature, precipitation, and relative humidity. The objectives of the current study were to analyse and model the relationships among climate, vector and malaria disease in district of Visakhapatnam, India to understand malaria transmission mechanism (MTM). Methodology Epidemiological, vector and climate data were analysed for the years 2005 to 2011 in Visakhapatnam to understand the magnitude, trends and seasonal patterns of the malarial disease. Statistical software MINITAB ver. 14 was used for performing correlation, linear and multiple regression analysis. Results/Findings Perennial malaria disease incidence and mosquito population was observed in the district of Visakhapatnam with peaks in seasons. All the climatic variables have a significant influence on disease incidence as well as on mosquito populations. Correlation coefficient analysis, seasonal index and seasonal analysis demonstrated significant relationships among climatic factors, mosquito population and malaria disease incidence in the district of Visakhapatnam, India. Multiple regression and ARIMA (I) models are best suited models for modeling and prediction of disease incidences and mosquito population. Predicted values of average temperature, mosquito population and malarial cases increased along with the year. Developed MTM algorithm observed a major MTM cycle following the June to August rains and occurring between June to September and minor MTM cycles following March to April rains and occurring between March to April in the district of Visakhapatnam. Fluctuations in climatic factors favored an increase in mosquito populations and thereby increasing the number of malarial cases. Rainfall, temperatures (20°C to 33°C) and humidity (66% to 81%) maintained a warmer, wetter climate for mosquito growth, parasite development and malaria transmission. Conclusions/Significance Changes in climatic factors influence malaria directly by modifying the behaviour and geographical distribution of vectors and by changing the length of the life cycle of the parasite. PMID:26110279

  2. A safe and accurate method to perform esthetic mandibular contouring surgery for Far Eastern Asians.

    PubMed

    Hsieh, A M-C; Huon, L-K; Jiang, H-R; Liu, S Y-C

    2017-05-01

    A tapered mandibular contour is popular with Far Eastern Asians. This study describes a safe and accurate method of using preoperative virtual surgical planning (VSP) and an intraoperative ostectomy guide to maximize the esthetic outcomes of mandibular symmetry and tapering while mitigating injury to the inferior alveolar nerve (IAN). Twelve subjects with chief complaints of a wide and square lower face underwent this protocol from January to June 2015. VSP was used to confirm symmetry and preserve the IAN while maximizing the surgeon's ability to taper the lower face via mandibular inferior border ostectomy. The accuracy of this method was confirmed by superimposition of the perioperative computed tomography scans in all subjects. No subjects complained of prolonged paresthesia after 3 months. A safe and accurate protocol for achieving an esthetic lower face in indicated Far Eastern individuals is described. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  3. APPLICATION OF A DUAL FINE PARTICLE SEQUENTIAL SAMPLER, A TAPERED ELEMENT OSCILLATING MICROBALANCE, AND OTHER AIR MONITORING METHODS TO ASSESS TRANSBOUNDARY INFLUENCE OF PM 2.5

    EPA Science Inventory

    Transboundary influences of paniculate matter less than or equal to 2.5 um in aerodynamic diameter (PM2.5,) have been investigated in a U.S.-Mexican border region using a dual fine particle sequential sampler (DFPSS) and tapered element oscillating microbalance (TEOM). Daily me...

  4. Method and device for reducing overpenetration at the start of plasma arc welds

    DOEpatents

    Sanders, John M.; Lehmann, John M.; Ryan, Patrick M.

    1998-01-01

    A shim for improving plasma arc weld quality has ends tapered at about 25.degree. and notches at each end roughly centered over the corner between the tapered ends and main body of the shim. The improved shim allows lower starting plasma arc heat input and reduces the occurrence of sagging, or overpenetration, of the weld.

  5. Automated touch sensing in the mouse tapered beam test using Raspberry Pi.

    PubMed

    Ardesch, Dirk Jan; Balbi, Matilde; Murphy, Timothy H

    2017-11-01

    Rodent models of neurological disease such as stroke are often characterized by motor deficits. One of the tests that are used to assess these motor deficits is the tapered beam test, which provides a sensitive measure of bilateral motor function based on foot faults (slips) made by a rodent traversing a gradually narrowing beam. However, manual frame-by-frame scoring of video recordings is necessary to obtain test results, which is time-consuming and prone to human rater bias. We present a cost-effective method for automated touch sensing in the tapered beam test. Capacitive touch sensors detect foot faults onto the beam through a layer of conductive paint, and results are processed and stored on a Raspberry Pi computer. Automated touch sensing using this method achieved high sensitivity (96.2%) as compared to 'gold standard' manual video scoring. Furthermore, it provided a reliable measure of lateralized motor deficits in mice with unilateral photothrombotic stroke: results indicated an increased number of contralesional foot faults for up to 6days after ischemia. The automated adaptation of the tapered beam test produces results immediately after each trial, without the need for labor-intensive post-hoc video scoring. It also increases objectivity of the data as it requires less experimenter involvement during analysis. Automated touch sensing may provide a useful adaptation to the existing tapered beam test in mice, while the simplicity of the hardware lends itself to potential further adaptations to related behavioral tests. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Ceramic Heads Decrease Metal Release Caused by Head-taper Fretting and Corrosion.

    PubMed

    Kocagoz, Sevi B; Underwood, Richard J; MacDonald, Daniel W; Gilbert, Jeremy L; Kurtz, Steven M

    2016-04-01

    Metal release resulting from taper fretting and corrosion is a clinical concern, because wear and corrosion products may stimulate adverse local tissue reactions. Unimodular hip arthroplasties have a conical taper between the femoral head (head bore taper) and the femoral stem (stem cone taper). The use of ceramic heads has been suggested as a way of reducing the generation of wear and corrosion products from the head bore/stem cone taper junction. A previous semiquantitative study found that ceramic heads had less visual evidence of fretting-corrosion damage compared with CoCr heads; but, to our knowledge, no studies have quantified the volumetric material loss from the head bore and stem cone tapers of a matched cohort of ceramic and metal heads. We asked: (1) Do ceramic heads result in less volume of material loss at the head-stem junction compared with CoCr heads; (2) do stem cone tapers have less volumetric material loss compared with CoCr head bore tapers; (3) do visual fretting-corrosion scores correlate with volumetric material loss; and (4) are device, patient, or intraoperative factors associated with volumetric material loss? A quantitative method was developed to estimate volumetric material loss from the head and stem taper in previously matched cohorts of 50 ceramic and 50 CoCr head-stem pairs retrieved during revision surgery for causes not related to adverse reactions to metal particles. The cohorts were matched according to (1) implantation time, (2) stem flexural rigidity, and (3) lateral offset. Fretting corrosion was assessed visually using a previously published four-point, semiquantitative scoring system. The volumetric loss was measured using a precision roundness machine. Using 24 equally spaced axial traces, the volumetric loss was estimated using a linear least squares fit to interpolate the as-manufactured surfaces. The results of this analysis were considered in the context of device (taper angle clearance, head size, head offset, lateral offset, stem material, and stem surface finish) and patient factors that were obtained from the patients' operative records (implantation time, age at insertion, activity level, and BMI). The cumulative volumetric material losses estimated for the ceramic cohort had a median of 0.0 mm(3) per year (range, 0.0-0.4 mm(3)). The cumulative volumetric material losses estimated for the CoCr cohort had a median of 0.1 mm(3) per year (range, 0.0-8.8 mm(3)). An order of magnitude reduction in volumetric material loss was found when a ceramic head was used instead of a CoCr head (p < 0.0001). In the CoCr cohort, the femoral head bore tapers had a median material loss of 0.02 mm(3) (range, 0.0-8.7 mm(3)) and the stem cone tapers had a median material loss of 0.0 mm(3) (range, 0.0-0.32 mm(3)/year). There was greater material loss from femoral head bore tapers compared with stem cone tapers in the CoCr cohort (p < 0.001). There was a positive correlation between visual scoring and volumetric material loss (Spearman's ρ = 0.67, p < 0.01). Although visual scoring was effective for preliminary screening to separate tapers with no or mild damage from tapers with moderate to severe damage, it was not capable of discriminating in the large range of material loss observed at the taper surfaces with moderate to severe fretting-corrosion damage, indicated with a score of 3 or 4. We observed no correlations between volumetric material loss and device and patient factors. The majority of estimated material loss from the head bore-stem cone junctions resulting from taper fretting and corrosion was from the CoCr head bore tapers as opposed to the stem cone tapers. Additionally, the total material loss from the ceramic cohort showed a reduction in the amount of metal released by an order of magnitude compared with the CoCr cohort. We found that ceramic femoral heads may be an effective means by which to reduce metal release caused by taper fretting and corrosion at the head bore-stem cone modular interface in THAs.

  7. The role of group index engineering in series-connected photonic crystal microcavities for high density sensor microarrays

    PubMed Central

    Zou, Yi; Chakravarty, Swapnajit; Zhu, Liang; Chen, Ray T.

    2014-01-01

    We experimentally demonstrate an efficient and robust method for series connection of photonic crystal microcavities that are coupled to photonic crystal waveguides in the slow light transmission regime. We demonstrate that group index taper engineering provides excellent optical impedance matching between the input and output strip waveguides and the photonic crystal waveguide, a nearly flat transmission over the entire guided mode spectrum and clear multi-resonance peaks corresponding to individual microcavities that are connected in series. Series connected photonic crystal microcavities are further multiplexed in parallel using cascaded multimode interference power splitters to generate a high density silicon nanophotonic microarray comprising 64 photonic crystal microcavity sensors, all of which are interrogated simultaneously at the same instant of time. PMID:25316921

  8. Optimization of Maghemite (γ-Fe2O3) Nano-Powder Mixed micro-EDM of CoCrMo with Multiple Responses Using Gray Relational Analysis (GRA)

    NASA Astrophysics Data System (ADS)

    Mejid Elsiti, Nagwa; Noordin, M. Y.; Idris, Ani; Saed Majeed, Faraj

    2017-10-01

    This paper presents an optimization of process parameters of Micro-Electrical Discharge Machining (EDM) process with (γ-Fe2O3) nano-powder mixed dielectric using multi-response optimization Grey Relational Analysis (GRA) method instead of single response optimization. These parameters were optimized based on 2-Level factorial design combined with Grey Relational Analysis. The machining parameters such as peak current, gap voltage, and pulse on time were chosen for experimentation. The performance characteristics chosen for this study are material removal rate (MRR), tool wear rate (TWR), Taper and Overcut. Experiments were conducted using electrolyte copper as the tool and CoCrMo as the workpiece. Experimental results have been improved through this approach.

  9. Characterization of a 3D optrode array for infrared neural stimulation

    PubMed Central

    Abaya, T.V.F.; Diwekar, M.; Blair, S.; Tathireddy, P.; Rieth, L.; Clark, G.A.; Solzbacher, F.

    2012-01-01

    This paper characterizes the Utah Slant Optrode Array (USOA) as a means to deliver infrared light deep into tissue. An undoped crystalline silicon (100) substrate was used to fabricate 10 × 10 arrays of optrodes with rows of varying lengths from 0.5 mm to 1.5 mm on a 400-μm pitch. Light delivery from optical fibers and loss mechanisms through these Si optrodes were characterized, with the primary loss mechanisms being Fresnel reflection, coupling, radiation losses from the tapered shank and total internal reflection in the tips. Transmission at the optrode tips with different optical fiber core diameters and light in-coupling interfaces was investigated. At λ = 1.55μm, the highest optrode transmittance of 34.7%, relative to the optical fiber output power, was obtained with a 50-μm multi-mode fiber butt-coupled to the optrode through an intervening medium of index n = 1.66. Maximum power is directed into the optrodes when using fibers with core diameters of 200 μm or less. In addition, the output power varied with the optrode length/taper such that longer and less tapered optrodes exhibited higher light transmission efficiency. Output beam profiles and potential impacts on physiological tests were also examined. Future work is expected to improve USOA efficiency to greater than 64%. PMID:23024914

  10. Characterization of a 3D optrode array for infrared neural stimulation.

    PubMed

    Abaya, T V F; Diwekar, M; Blair, S; Tathireddy, P; Rieth, L; Clark, G A; Solzbacher, F

    2012-09-01

    This paper characterizes the Utah Slant Optrode Array (USOA) as a means to deliver infrared light deep into tissue. An undoped crystalline silicon (100) substrate was used to fabricate 10 × 10 arrays of optrodes with rows of varying lengths from 0.5 mm to 1.5 mm on a 400-μm pitch. Light delivery from optical fibers and loss mechanisms through these Si optrodes were characterized, with the primary loss mechanisms being Fresnel reflection, coupling, radiation losses from the tapered shank and total internal reflection in the tips. Transmission at the optrode tips with different optical fiber core diameters and light in-coupling interfaces was investigated. At λ = 1.55μm, the highest optrode transmittance of 34.7%, relative to the optical fiber output power, was obtained with a 50-μm multi-mode fiber butt-coupled to the optrode through an intervening medium of index n = 1.66. Maximum power is directed into the optrodes when using fibers with core diameters of 200 μm or less. In addition, the output power varied with the optrode length/taper such that longer and less tapered optrodes exhibited higher light transmission efficiency. Output beam profiles and potential impacts on physiological tests were also examined. Future work is expected to improve USOA efficiency to greater than 64%.

  11. Efficient multi-mode to single-mode coupling in a photonic lantern.

    PubMed

    Noordegraaf, Danny; Skovgaard, Peter M W; Nielsen, Martin D; Bland-Hawthorn, Joss

    2009-02-02

    We demonstrate the fabrication of a high performance multi-mode (MM) to single-mode (SM) splitter or "photonic lantern", first described by Leon-Saval et al. (2005). Our photonic lantern is a solid all-glass version, and we show experimentally that this device can be used to achieve efficient and reversible coupling between a MM fiber and a number of SM fibers, when perfectly matched launch conditions into the MM fiber are ensured. The fabricated photonic lantern has a coupling loss for a MM to SM tapered transition of only 0.32 dB which proves the feasibility of the technology.

  12. Spectral Estimation Techniques for time series with Long Gaps: Applications to Paleomagnetism and Geomagnetic Depth Sounding

    NASA Astrophysics Data System (ADS)

    Smith-Boughner, Lindsay

    Many Earth systems cannot be studied directly. One cannot measure the velocities of convecting fluid in the Earth's core but can measure the magnetic field generated by these motions on the surface. Examining how the magnetic field changes over long periods of time, using power spectral density estimation provides insight into the dynamics driving the system. The changes in the magnetic field can also be used to study Earth properties - variations in magnetic fields outside of Earth like the ring-current induce currents to flow in the Earth, generating magnetic fields. Estimating the transfer function between the external changes and the induced response characterizes the electromagnetic response of the Earth. From this response inferences can be made about the electrical conductivity of the Earth. However, these types of time series, and many others have long breaks in the record with no samples available and limit the analysis. Standard methods require interpolation or section averaging, with associated problems of introducing bias or reducing the frequency resolution. Extending the methods of Fodor and Stark (2000), who adapt a set of orthogonal multi-tapers to compensate for breaks in sampling- an algorithm and software package for applying these techniques is developed. Methods of empirically estimating the average transfer function of a set of tapers and confidence intervals are also tested. These methods are extended for cross-spectral, coherence and transfer function estimation in the presence of noise. With these methods, new analysis of a highly interrupted ocean sediment core from the Oligocene (Hartl et al., 1993) reveals a quasi-periodic signal in the calibrated paleointensity time series at 2.5 cpMy. The power in the magnetic field during this period appears to be dominated by reversal rate processes with less overall power than the early Oligocene. Previous analysis of the early Oligocene by Constable et al. (1998) detected a signal near 8 cpMy. These results suggest that a strong magnetic field inhibits reversals and has more variability in shorter term field changes. Using over 9 years of data from the CHAMP low-Earth orbiting magnetic satellite and the techniques developed here, more robust estimates of the electromagnetic response of the Earth can be made. The tapers adapted for gaps provide flexibility to study the effects of local time, storm conditions on Earth's 1-D electromagnetic response as well as providing robust estimates of the C-response at longer periods than previous satellite studies.

  13. Sealing ability of lateral compaction and tapered single cone gutta-percha techniques in root canals prepared with stainless steel and rotary nickel titanium instruments.

    PubMed

    Koçak, Mustafa M; Darendeliler-Yaman, Sis

    2012-07-01

    The aim of this study was to evaluate the sealing ability of lateral compaction and tapered single cone gutta-percha techniques in root canals prepared with stainless steel and rotary nickel titanium root canal instruments by fluid filtration method. The root canals were prepared with stainless steel (SS) and nickel titanium (NiTi) instruments. The canals prepared with SS were obturated with lateral compaction technique using .02 tapered cones and the canals prepared with NiTi instruments were obturated with lateral compaction technique using .02 tapered cones or 06 tapered single cones. The amount of leakage was evaluated by fluid filtration model. The results were statistically analyzed with one-way ANOVA. The group prepared with NiTi instruments and filled with lateral compaction technique showed significantly less coronal leakage than the group prepared with SS instruments and filled with lateral compaction technique (p<0.05). There was no statistically difference between apical leakages of groups (p>0.05). Obturation with lateral compaction of gutta-percha provides a superior coronal seal whilst canal instrumentation with engine-driven NiTi files reduces the extent of microleakage in root canals when compared with stainless steel hand instruments. Tapered single cone technique was comparable with lateral compaction technique because of easier application. Key words:Apical leakage, coronal leakage, lateral compaction technique, single cone technique.

  14. Selective excitation of LP01 and LP02 in dual-concentric cores fiber using an adiabatically tapered microstructured mode converter

    NASA Astrophysics Data System (ADS)

    Sammouda, Marwa; Taher, Aymen Belhadj; Bahloul, Faouzi; Bin, Philippe Di

    2016-09-01

    We propose to connect a single-mode fiber (SMF) to a dual-concentric cores fiber (DCCF) using an adiabatically tapered microstructured mode converter, and to evaluate the SMF LP01 mode and the DCCF LP01 and LP02 modes selective excitations performances. We theoretically and numerically study this selective excitation method by calculating the effective indices of the propagated modes, the adiabaticity criteria, the coupling loss, and the modes amplitudes along the tapered structure. This study shows that this method is able to achieve excellent selective excitations of the first two linearly polarized modes (LP01 and LP02) among the five guided modes in the DCCF with a negligible loss. The part of the LP01 and LP02 modes from the total power are 99% and 84% corresponding to 0.1 and 0.8 dB losses, respectively.

  15. Simple taper: Taper equations for the field forester

    Treesearch

    David R. Larsen

    2017-01-01

    "Simple taper" is set of linear equations that are based on stem taper rates; the intent is to provide taper equation functionality to field foresters. The equation parameters are two taper rates based on differences in diameter outside bark at two points on a tree. The simple taper equations are statistically equivalent to more complex equations. The linear...

  16. Parabolic tapers for overmoded waveguides

    DOEpatents

    Doane, J.L.

    1983-11-25

    A waveguide taper with a parabolic profile, in which the distance along the taper axis varies as the square of the tapered dimension, provides less mode conversion than equal length linear tapers and is easier to fabricate than other non-linear tapers.

  17. Retention Load of Telescopic Crowns with Different Taper Angles between Cobalt-Chromium and Polyetheretherketone Made with Three Different Manufacturing Processes Examined by Pull-Off Test.

    PubMed

    Wagner, Christina; Stock, Veronika; Merk, Susanne; Schmidlin, Patrick R; Roos, Malgorzata; Eichberger, Marlis; Stawarczyk, Bogna

    2018-02-01

    To investigate the retention loads of differently fabricated secondary telescopic polyetheretherketone (PEEK) crowns on cobalt-chromium primary crowns with different tapers. Cobalt-chromium primary crowns with 0°, 1°, and 2° tapers were constructed, milled, and sintered. Corresponding secondary crowns were fabricated by milling, pressing from pellets, and pressing from granules. For these nine test groups, the pull-off tests of each crown combination were performed 20 times, and the retention loads were measured (Zwick 1445, 50 mm/min). Data were analyzed using linear regression, covariance analysis, mixed models, Kruskal-Wallis, and Mann-Whitney U-test, together with the Benferroni-Holm correction. The mixed models covariance analysis reinforced stable retention load values (p = 0.162) for each single test sequence. There was no interaction between the groups and the separation cycles (p = 0.179). Milled secondary crowns with 0° showed the lowest mean retention load values compared to all tested groups (p = 0.003) followed by those pressed form pellets with 1°. Regarding the different tapers, no effect of manufacturing method on the results was observed within 1° and 2° groups (p = 0.540; p = 0.052); however, among the 0° groups, the milled ones showed significantly the lowest retention load values (p = 0.002). Among the manufacturing methods, both pressed groups showed no impact of taper on the retention load values (p > 0.324 and p > 0.123, respectively), whereas among the milled secondary crowns, the 0° taper showed significantly lower retention load values than the 1° and 2° taper (p < 0.002). Based on these results, telescopic crowns made of PEEK seem to show stable retention load values for each test sequence; however, data with thermo-mechanical aging are still required. In addition, further developments in CAD/CAM manufacturing of PEEK materials for telescopic crowns are warranted, especially for 0°. © 2016 by the American College of Prosthodontists.

  18. Gyroharmonic converter as a multi-megawatt RF driver for NLC: Beam source considerations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, C.; Hirshfield, J.L.

    1995-06-01

    A multi-megawatt 14.28 GHz gyroharmonic converter under construction at Yale University depends critically on the parameters of an electron beam prepared using a cyclotron autoresonance accelerator (CARA). This paper extends prior analysis of CARA to find an approximate constant-of-the-motion, and to give limits to the beam energy from CARA that can be utilized in a harmonic converter. It is also shown that particles are strongly phase trapped during acceleration in CARA, and thus are insensitive to deviations from exact autoresonance. This fact greatly simplifies construction of the up-tapered guide magnetic field in the device, and augurs well for production ofmore » high-quality multi-megawatt beams using CARA. {copyright} 1995 {ital American Institute of Physics}.« less

  19. Experimental study of electrical discharge drilling of stainless steel UNS S30400

    NASA Astrophysics Data System (ADS)

    Hanash, E. A. H.; Ali, M. Y.

    2018-01-01

    In this study, overcut and taper angle were investigated in machining of stainless steel UNS S30400 against three different electrical discharge machining parameters which are electric current (Ip), pulse on-time (Ton) and pulse off-time (Toff). The electrode used was of 1 mm diameter with aspect ratio of 10. Dimensional accuracy was measured by evaluating overcut and taper angle. Those two measurements were performed using optical microscope model (Olympus BX41M, Japan). The experimentation planning, evaluation, analysis and optimization have been carried out using DOE software version 10.0.3 RSM based method with total number of twenty experiments. The research reveals that, discharge current was found to have the most significant effect on overcut and taper angle followed by pulse on-time and pulse off-time. As the discharge current and pulse on-time increase, overcut and taper angle are increased. However, when pulse off-time increases, overcut and taper angle decrease. The outcome result of this study will be very useful in the manufacturing industry to select the appropriate parameters for the selected work material. The model has shown a great accuracy with percentage error of less than 5%.

  20. Tapered microelectrode array system for dielectrophoretically filtration: fabrication, characterization, and simulation study

    NASA Astrophysics Data System (ADS)

    Buyong, Muhamad Ramdzan; Larki, Farhad; Takamura, Yuzuru; Majlis, Burhanuddin Yeop

    2017-10-01

    This paper presents the fabrication, characterization, and simulation of microelectrode arrays system with tapered profile having an aluminum surface for dielectrophoresis (DEP)-based manipulation of particles. The proposed structure demonstrates more effective electric field gradient compared with its counterpart with untapered profile. Therefore, according to the asymmetric distribution of the electric field in the active region of microelectrode, it produces more effective particle manipulation. The tapered aluminum microelectrode array (TAMA) fabrication process uses a state-of-the-art technique in the formation of the resist's taper profile. The performance of TAMA with various sidewall profile angles (5 deg to 90 deg) was analyzed through finite-element method numerical simulations to offer a better understanding of the origin of the sidewall profile effect. The ability of capturing and manipulating of the device was examined through modification of the Clausius-Mossotti factor and cross-over frequency (f). The fabricated system has been particularly implemented for filtration of particles with a desired diameter from a mixture of particles with three different diameters in an aqueous medium. The microelectrode system with tapered side wall profile offers a more efficient platform for particle manipulation and sensing applications compared with the conventional microelectrode systems.

  1. Method of making tapered capillary tips with constant inner diameters

    DOEpatents

    Kelly, Ryan T [West Richland, WA; Page, Jason S [Kennewick, WA; Tang, Keqi [Richland, WA; Smith, Richard D [Richland, WA

    2009-02-17

    Methods of forming electrospray ionization emitter tips are disclosed herein. In one embodiment, an end portion of a capillary tube can be immersed into an etchant, wherein the etchant forms a concave meniscus on the outer surface of the capillary. Variable etching rates in the meniscus can cause an external taper to form. While etching the outer surface of the capillary wall, a fluid can be flowed through the interior of the capillary tube. Etching continues until the immersed portion of the capillary tube is completely etched away.

  2. Phase-shift detection in a Fourier-transform method for temperature sensing using a tapered fiber microknot resonator.

    PubMed

    Larocque, Hugo; Lu, Ping; Bao, Xiaoyi

    2016-04-01

    Phase-shift detection in a fast-Fourier-transform (FFT)-based spectrum analysis technique for temperature sensing using a tapered fiber microknot resonator is proposed and demonstrated. Multiple transmission peaks in the FFT spectrum of the device were identified as optical modes having completed different amounts of round trips within the ring structure. Temperature variation induced phase shifts for each set of peaks were characterized, and experimental results show that different peaks have distinct temperature sensitivities reaching values up to -0.542  rad/°C, which is about 10 times greater than that of a regular adiabatic taper Mach-Zehnder interferometer when using similar phase-tracking schemes.

  3. Design and optimization of broadband tapered optical fibers with a nanofiber waist.

    PubMed

    Stiebeiner, Ariane; Garcia-Fernandez, Ruth; Rauschenbeutel, Arno

    2010-10-25

    The control over the transmission properties of tapered optical fibers (TOFs) is an important requirement for a whole range of applications. Using a carefully designed flame pulling process that allows us to realize preset fiber radius profiles, we fabricate TOFs with a nanofiber waist. We study the spectral transmission properties of these TOFs as a function of the taper profile and the waist length and show how the transmission band of the TOF can be tuned via different fiber profile parameters. Based on these results, we have designed a nanofiber-waist TOF with broadband transmission for surface spectroscopy of organic molecules. Moreover, our method allows us to analyze the loss mechanisms of optical nanofibers.

  4. Effect of three different rotary instrumentation systems on postinstrumentation pain: A randomized clinical trial

    PubMed Central

    Subbiya, Arunajatesan; Cherkas, Pavel S.; Vivekanandhan, Paramasivam; Geethapriya, Nagarajan; Malarvizhi, Dhakshinamoorthy; Mitthra, Suresh

    2017-01-01

    Background: Endodontic instrumentation is liable to cause some postinstrumentation pain (PIP). Rotary endodontic instruments differ in their design, metallurgy, surface treatment, etc. Aim: This randomized clinical trial aimed to assess the incidence of PIP after root canal instrumentation with three different rotary endodontic systems which differ in their design, namely, ProTaper, Mtwo, and K3. Materials and Methods: A total of 150 patients between the ages of 25 and 50 were chosen for the study. Teeth with asymptomatic irreversible pulpitis due to carious exposure were selected. The patients received local anesthesia by inferior alveolar nerve block. After preparing the access cavity, root canal instrumentation was done with one of the three instruments (n = 50) and closed dressing was given. PIP was assessed every 12 h for 5 days, and tenderness to percussion was analyzed at the end of 1, 3, and 7 days. Statistical Analysis: Mann–Whitney U-test to determine significant differences at P < 0.01. Results: The PIP and tenderness were less in Mtwo group when compared to ProTaper and K3 groups up to 84 h and 72 h respectively and statistically significant (P < 0.05). There was no statistically significant difference between ProTaper and K3 both in PIP and tenderness. Conclusion: Rotary endodontic instrumentation causes some degree of PIP and tenderness to percussion. Among the instruments used, Mtwo causes less PIP and tenderness when compared to ProTaper and K3, and there was no difference between ProTaper and K3. Clinical Relevance: PIP is highly subjective and may vary among different subjects. The apical (3 mm) taper of ProTaper was 0.08 followed by a smaller taper, whereas, the other two files were of a constant 0.06 taper, which means there could have been a greater apical extrusion and therefore more PIP. Despite, the mean of the age was similar, there could have been a difference in the size of the canal and therefore a difference in apical extrusion and PIP. PMID:29430103

  5. Mental health, fatigue and function are associated with increased risk of disease flare following TNF inhibitor tapering in patients with rheumatoid arthritis: an exploratory analysis of data from the Optimizing TNF Tapering in RA (OPTTIRA) trial

    PubMed Central

    Bechman, Katie; Sin, Fang En; Ibrahim, Fowzia; Norton, Sam; Matcham, Faith; Scott, David Lloyd; Cope, Andrew; Galloway, James

    2018-01-01

    Background Tapering of anti-tumour necrosis factor (TNF) therapy appears feasible, safe and effective in selected patients with rheumatoid arthritis (RA). Depression is highly prevalent in RA and may impact on flare incidence through various mechanisms. This study aims to investigate if psychological states predict flare in patients’ dose tapering their anti-TNF therapy. Methods This study is a post-hoc analysis of the Optimizing TNF Tapering in RA trial, a multicentre, randomised, open-label study investigating anti-TNF tapering in RA patients with sustained low disease activity. Patient-reported outcomes (Health Assessment Questionnaire, EuroQol 5-dimension scale, Functional Assessment of Chronic Illness Therapy fatigue scale (FACIT-F), 36-Item Short Form Survey (SF-36)) were collected at baseline. The primary outcome was flare, defined as an increase in 28-joint count Disease Activity Score (DAS28) ≥0.6 and ≥1 swollen joint. Discrete-time survival models were used to identify patient-reported outcomes that predict flare. Results Ninety-seven patients were randomised to taper their anti-TNF dose by either 33% or 66%. Forty-one patients flared. Higher baseline DAS28 score was associated with flare (adjusted HR 1.96 (95% CI 1.18 to 3.24), p=0.01). Disability (SF-36 physical component score), fatigue (FACIT-F) and mental health (SF-36 mental health subscale (MH)) predicted flare in unadjusted models. In multivariate analyses, only SF-36 MH remained a statistically significant predictor of flare (adjusted HR per 10 units 0.74 (95% CI 0.60 to 0.93), p=0.01). Conclusions Baseline DAS28 and mental health status are independently associated with flare in patients who taper their anti-TNF therapy. Fatigue and function also associate with flare but the effect disappears when adjusting for confounders. Given these findings, mental health and functional status should be considered in anti-TNF tapering decisions in order to optimise the likelihood of success. Trial registration numbers EudraCT Number: 2010-020738-24; ISRCTN: 28955701; Post-results. PMID:29862047

  6. Connecting Molecular Dynamics Simulations and Fluids Density Functional Theory of Block Copolymers

    NASA Astrophysics Data System (ADS)

    Hall, Lisa

    Increased understanding and precise control over the nanoscale structure and dynamics of microphase separated block copolymers would advance development of mechanically robust but conductive materials for battery electrolytes, among other applications. Both coarse-grained molecular dynamics (MD) simulations and fluids (classical) density functional theory (fDFT) can capture the microphase separation of block copolymers, using similar monomer-based chain models and including local packing effects. Equilibrium free energies of various microphases are readily accessible from fDFT, which allows us to efficiently determine the equilibrium nanostructure over a large parameter space. Meanwhile, MD allows us to visualize specific polymer conformations in 3D over time and to calculate dynamic properties. The fDFT density profiles are used to initialize the MD simulations; this ensures the MD proceeds in the appropriate microphase separated state rather than in a metastable structure (useful especially for nonlamellar structures). The simulations equilibrate more quickly than simulations initialized with a random state, which is significant especially for long chains. We apply these methods to study the interfacial behavior and microphase separated structure of diblock and tapered block copolymers. Tapered copolymers consist of pure A and B monomer blocks on the ends separated by a tapered region that smoothly varies from A to B (or from B to A for an inverse taper). Intuitively, tapering increases the segregation strength required for the material to microphase separate and increases the width of the interfacial region. Increasing normal taper length yields a lower domain spacing and increased polymer mobility, while larger inverse tapers correspond to even lower domain spacing but decreased mobility. Thus the changes in dynamics with tapering cannot be explained by mapping to a diblock system at an adjusted effective segregation strength. This material is based upon work supported by the National Science Foundation under Grant 1454343 and the Department of Energy under Grant DE-SC0014209.

  7. Supercontinuum generation in a tapered tellurite microstructured optical fiber

    NASA Astrophysics Data System (ADS)

    Yan, X.; Ohishi, Y.

    2014-07-01

    Supercontinuum generation (SCG) was investigated in tapered tellurite microstructured optical fibers (MOFs) for various taper profiles. We emphasize on the procedure for finding the dispersion profile that achieve the best width of the SC spectra. An enhancement of the SCG is achieved by varying the taper waist diameter along its length in a carefully designed, and an optimal degree of tapering is found to exist for tapers with an axially uniform waist. We also show the XFROG spectrograms of the pulses propagating through different tapered fibers, confirming the optimized taper conditions.

  8. All-fiber magnetic field sensor based on tapered thin-core fiber and magnetic fluid.

    PubMed

    Zhang, Junying; Qiao, Xueguang; Yang, Hangzhou; Wang, Ruohui; Rong, Qiangzhou; Lim, Kok-Sing; Ahmad, Harith

    2017-01-10

    A method for the measurement of a magnetic field by combining a tapered thin-core fiber (TTCF) and magnetic fluid is proposed and experimentally demonstrated. The modal interference effect is caused by the core mode and excited eigenmodes in the TTCF cladding. The transmission spectra of the proposed sensor are measured and theoretically analyzed at different magnetic field strengths. The results field show that the magnetic sensitivity reaches up to -0.1039  dB/Oe in the range of 40-1600 e. The proposed method possesses high sensitivity and low cost compared with other expensive methods.

  9. Impact of root canal preparation size and taper on coronal-apical micro-leakage using glucose penetration method

    PubMed Central

    Tabrizizadeh, Mehdi; Hekmati-Moghadam, Seyed-Hossein; Hakimian, Roqayeh

    2014-01-01

    Objectives: The purpose of this in vitro study was to assess the effect of root canal preparation size and taper on the amounts of glucose penetration. Material and Methods: For conducting this experimental study, eighty mandibular premolars with single straight canals were divided randomly into 2 experimental groups of 30 samples each and 2 control groups. Using K-files and the balance force technique, canals in group 1 were prepared apically to size 25 and coronally to size 2 Peesoreamer. Group 2 were instrumented apically and coronally to size 40 and size 6 Peesoreamer, respectively. Rotary instrumentation was accomplished in group 1; using size 25 and .04 tapered and in group 2, size 35 and .06 tapered Flex Master files. Canals were then obturated by lateral compaction of cold gutta-percha. Glucose penetration through root canal fillings was measured at 1, 8, 15, 22 and 30 days. Data were recorded as mmol/L and statistically analyzed with Mann-Whitney U test (P value=. 05). Results: In comparison to group 1, group 2 showed significant glucose leakage during the experimental period (P value < .0001). Also, in each experimental group, the amount of micro-leakage was significantly increased at the end of the study. Conclusions: Under the condition of this study, the amounts of micro-leakage through root canal fillings are directly related to the size and taper of root canal preparation and reducing the preparation size may lead to less micro-leakage. Key words:Dental leakage, root canal preparation, endodontics. PMID:25593654

  10. Efficacy of ProTaper and Mtwo Retreatment Files in Removal of Gutta-percha and GuttaFlow from Root Canals

    PubMed Central

    Khedmat, Sedigheh; Azari, Abbas; Shamshiri, Ahmad Reza; Fadae, Mehdi; Bashizadeh Fakhar, Hoorieh

    2016-01-01

    Introduction: The aim of this in vitro study was to compare the efficacy of ProTaper retreatment (ProTaper R) and Mtwo retreatment (Mtwo R) files in removing gutta-percha and GuttaFlow from endodontically treated straight root canals. Methods and Materials: The root canals of 60 human mandibular single-rooted premolars were prepared and randomly divided into two groups (n=30). In groups A and B the root canals were obturated using lateral condensation of gutta-percha plus AH 26 and GuttaFlow, respectively. The canal orifices were temporarily sealed and the roots were incubated for 3 months at 37ºC and 100% humidity. Primary cone-beam computed tomography (CBCT) images were taken after incubation period. The specimens in each group were randomly divided into two subgroups (n=15). ProTaper R files (D1, D2, and D3) were used in groups A1 and B1 while Mtwo R files (25/0.05 and 15/0.05) were used in groups A2 and B2. The time required to extirpate the root filling was also recorded. After retreatment, another CBCT scan was taken at the same position. The volume of remaining filling materials inside the canals was calculated before and after retreatment. The data was analyzed using the two-way ANOVA and independent t-test. Results: The remaining filling materials in the canals treated with ProTaper were less than Mtwo. The remaining volume of GuttaFlow was less than gutta-percha regardless of the system applied. Mtwo R files removed root fillings faster than ProTaper R. Conclusion: ProTaper R removed filling material more efficiently compared to Mtwo R which required less time to remove root filling material. PMID:27471528

  11. Evaluation of the incidence of microcracks caused by Mtwo and ProTaper Next rotary file systems versus the self-adjusting file: A scanning electron microscopic study

    PubMed Central

    Saha, Suparna Ganguly; Vijaywargiya, Neelam; Saxena, Divya; Saha, Mainak Kanti; Bharadwaj, Anuj; Dubey, Sandeep

    2017-01-01

    Introduction: To evaluate the incidence of microcrack formation canal preparation with two rotary nickel–titanium systems Mtwo and ProTaper Next along with the self-adjusting file system. Materials and Methods: One hundred and twenty mandibular premolar teeth were selected. Standardized access cavities were prepared and the canals were manually prepared up to size 20 after coronal preflaring. The teeth were divided into three experimental groups and one control group (n = 30). Group 1: The canals were prepared using Mtwo rotary files. Group 2: The canals were prepared with ProTaper Next files. Group 3: The canals were prepared with self-adjusting files. Group 4: The canals were unprepared and used as a control. The roots were sectioned horizontally 3, 6, and 9 mm from the apex and examined under a scanning electron microscope to check for the presence of microcracks. The Pearson's Chi-square test was applied. Results: The highest incidence of microcracks were associated with the ProTaper Next group, 80% (P = 0.00), followed by the Mtwo group, 70% (P = 0.000), and the least number of microcracks was noted in the self-adjusting file group, 10% (P = 0.068). No significant difference was found between the ProTaper Next and Mtwo groups (P = 0.368) while a significant difference was observed between the ProTaper Next and self-adjusting file groups (P = 0.000) as well as the Mtwo and self-adjusting file groups (P = 0.000). Conclusion: All nickel–titanium rotary instrument systems were associated with microcracks. However, the self-adjusting file system had significantly fewer microcracks when compared with the Mtwo and ProTaper Next. PMID:29386786

  12. Effectiveness of ProTaper Universal retreatment instruments used with rotary or reciprocating adaptive motion in the removal of root canal filling material.

    PubMed

    Capar, I D; Arslan, H; Ertas, H; Gök, T; Saygılı, G

    2015-01-01

    To compare the effectiveness of ProTaper Universal retreatment instruments with continuous rotation and adaptive motion (AM; a modified reciprocating motion that combines rotational and reciprocating motion) in the removal of filling material. Mesiobuccal root canals in 36 mandibular first molars were instrumented up to size F2 with the ProTaper Universal instrument (Dentsply Maillefer, Ballaigues, Switzerland) and filled using sealer and ProTaper Universal F2 gutta-percha cones. Gutta-percha was then down-packed and the root canal backfilled using the extruder hand-piece of the Elements Obturation System (SybronEndo, Orange, CA, USA). The teeth were assigned to two groups (n = 18), and removal of the root fillings was performed using one of the following techniques: group 1) ProTaper Universal retreatment files used with rotational motion (RM) and group 2) ProTaper Universal retreatment files used with adaptive motion (AM) (600° clockwise/0° counter-clockwise to 370° clockwise/50° counter-clockwise). The teeth were sectioned, and both halves were analysed at 8 × magnification. The percentage of remaining filling material was recorded. The data were analysed statistically using the Student's t-test at a 95% confidence level (P < 0.05). There was no significant difference between the groups with respect to the total time required for retreatment (P = 0.481). The AM technique left significantly less filling material than the RM method (P = 0.013). The use of ProTaper Universal retreatment files with adaptive motion removed more filling materials from root canals than the rotational movement. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  13. Monitoring training load, recovery-stress state, immune-endocrine responses, and physical performance in elite female basketball players during a periodized training program.

    PubMed

    Nunes, João A; Moreira, Alexandre; Crewther, Blair T; Nosaka, Ken; Viveiros, Luis; Aoki, Marcelo S

    2014-10-01

    This study investigated the effect of a periodized training program on internal training load (ITL), recovery-stress state, immune-endocrine responses, and physical performance in 19 elite female basketball players. The participants were monitored across a 12-week period before an international championship, which included 2 overloading and tapering phases. The first overloading phase (fourth to sixth week) was followed by a 1-week tapering, and the second overloading phase (eighth to 10th week) was followed by a 2-week tapering. ITL (session rating of perceived exertion method) and recovery-stress state (RESTQ-76 Sport questionnaire) were assessed weekly and bi-weekly, respectively. Pretraining and posttraining assessments included measures of salivary IgA, testosterone and cortisol concentrations, strength, jumping power, running endurance, and agility. Internal training load increased across all weeks from 2 to 11 (p ≤ 0.05). After the first tapering period (week 7), a further increase in ITL was observed during the second overloading phase (p ≤ 0.05). After the second tapering period, a decrease in ITL was detected (p ≤ 0.05). A disturbance in athlete stress-recovery state was noted during the second overloading period (p ≤ 0.05), before returning to baseline level in end of the second tapering period. The training program led to significant improvements in the physical performance parameters evaluated. The salivary measures did not change despite the fluctuations in ITL. In conclusion, a periodized training program evoked changes in ITL in elite female basketball players, which appeared to influence their recovery-stress state. The training plan was effective in preparing participants for competition, as indicated by improvements in recovery-stress state and physical performance after tapering.

  14. Freeze-drying in novel container system: Characterization of heat and mass transfer in glass syringes.

    PubMed

    Patel, Sajal M; Pikal, Michael J

    2010-07-01

    This study is aimed at characterizing and understanding different modes of heat and mass transfer in glass syringes to develop a robust freeze-drying process. Two different holder systems were used to freeze-dry in syringes: an aluminum (Al) block and a plexiglass holder. The syringe heat transfer coefficient was characterized by a sublimation test using pure water. Mannitol and sucrose (5% w/v) were also freeze-dried, as model systems, in both the assemblies. Dry layer resistance was determined from manometric temperature measurement (MTM) and product temperature was measured using thermocouples, and was also determined from MTM. Further, freeze-drying process was also designed using Smart freeze-dryer to assess its application for freeze-drying in novel container systems. Heat and mass transfer in syringes were compared against the traditional container system (i.e., glass tubing vial). In the Al block, the heat transfer was via three modes: contact conduction, gas conduction, and radiation with gas conduction being the dominant mode of heat transfer. In the plexiglass holder, the heat transfer was mostly via radiation; convection was not involved. Also, MTM/Smart freeze-drying did work reasonably well for freeze-drying in syringes. When compared to tubing vials, product temperature decreases and hence drying time increases in syringes. (c) 2010 Wiley-Liss, Inc. and the American Pharmacists Association

  15. TBM/MTM for HTS-FNSF: An innovative testing strategy to qualify/validate fusion technologies for U.S. DEMO

    DOE PAGES

    El-Guebaly, Laila; Rowcliffe, Arthur; Menard, Jonathan; ...

    2016-08-11

    The qualification and validation of nuclear technologies are daunting tasks for fusion demonstration (DEMO) and power plants. This is particularly true for advanced designs that involve harsh radiation environment with 14 MeV neutrons and high-temperature operating regimes. This paper outlines the unique qualification and validation processes developed in the U.S., offering the only access to the complete fusion environment, focusing on the most prominent U.S. blanket concept (the dual cooled PbLi (DCLL)) along with testing new generations of structural and functional materials in dedicated test modules. The venue for such activities is the proposed Fusion Nuclear Science Facility (FNSF), whichmore » is viewed as an essential element of the U.S. fusion roadmap. A staged blanket testing strategy has been developed to test and enhance the DCLL blanket performance during each phase of FNSF D-T operation. A materials testing module (MTM) is critically important to include in the FNSF as well to test a broad range of specimens of future, more advanced generations of materials in a relevant fusion environment. Here, the most important attributes for MTM are the relevant He/dpa ratio (10–15) and the much larger specimen volumes compared to the 10–500 mL range available in the International Fusion Materials Irradiation Facility (IFMIF) and European DEMO-Oriented Neutron Source (DONES).« less

  16. Evaluation of Sandwich Structure Bonding In Out-of-Autoclave Processing

    NASA Technical Reports Server (NTRS)

    Hou, Tan-Hung; Baughman, James M.; Zimmerman, Thomas J.; Sutter, James K.; Gardner, John M.

    2010-01-01

    The out-of-autoclave-vacuum-bag-only (OOA-VBO) process is low in capital expenditures compared to the traditional autoclave, however, the material challenges for OOA-VBO workable material systems are high. Presently there are few such aerospace grade prepreg materials available commercially. In this study, we evaluated processing and properties of honeycomb sandwich structure (HC/SS) panels fabricated by co-curing composite face sheet with adhesives by the OOA-VBO process in an oven. The prepreg materials were IM7/MTM 45-1 and T40-800B/5320. Adhesives studied were AF-555M, XMTA-241/PM15, FM-309-1M and FM-300K. Aluminum H/C cores with and without perforations were included. It was found that adhesives in IM7/MTM 45-1/AF-555M, T40-800B/5320/FM 309-1M and T40-800B/5320/FM-300K panels all foamed but yielded high flatwise tensile (FWT) strength values above 8,275 kPA (1,200 psi). IM7/MTM 45-1/XMTA-241/PM15 did not foam, yet yielded a low FWT strength. SEM photomicrographs revealed that the origin of this low strength was poor adhesion in the interfaces between the adhesive and face sheet composite due to poor wetting associated with the high initial viscosity of the XMTA-241/PM15 adhesive.

  17. Tapering Practices of Strongman Athletes: Test-Retest Reliability Study

    PubMed Central

    Pritchard, Hayden J; Keogh, Justin WL

    2017-01-01

    Background Little is currently known about the tapering practices of strongman athletes. We have developed an Internet-based comprehensive self-report questionnaire examining the training and tapering practices of strongman athletes. Objective The objective of this study was to document the test-retest reliability of questions associated with the Internet-based comprehensive self-report questionnaire on the tapering practices of strongman athletes. The information will provide insight on the reliability and usefulness of the online questionnaire for use with strongman athletes. Methods Invitations to complete an Internet questionnaire were sent via Facebook Messenger to identified strongman athletes. The survey consisted of four main areas of inquiry, including demographics and background information, training practices, tapering, and tapering practices. Of the 454 athletes that completed the survey over the 8-week period, 130 athletes responded on Facebook Messenger indicating that they intended to complete, or had completed, the survey. These participants were asked if they could complete the online questionnaire a second time for a test-retest reliability analysis. Sixty-four athletes (mean age 33.3 years, standard deviation [SD] 7.7; mean height 178.2 cm, SD 11.0; mean body mass 103.7 kg, SD 24.8) accepted this invitation and completed the survey for the second time after a minimum 7-day period from the date of their first completion. Agreement between athlete responses was measured using intraclass correlation coefficients (ICCs) and kappa statistics. Confidence intervals (at 95%) were reported for all measures and significance was set at P<.05. Results Test-retest reliability for demographic and training practices items were significant (P<.001) and showed excellent (ICC range=.84 to .98) and fair to almost perfect agreement (κ range=.37-.85). Moderate to excellent agreements (ICC range=.56-.84; P<.01) were observed for all tapering practice measures except for the number of days athletes started their usual taper before a strongman competition (ICC=.30). When the number of days were categorized with additional analyses, moderate reliability was observed (κ=.43; P<.001). Fair to substantial agreement was observed for the majority of tapering practices measures (κrange=.38-.73; P<.001) except for how training frequency (κ=.26) and the percentage and type of resistance training performed, which changed in the taper (κ=.20). Good to excellent agreement (ICC=.62-.93; P<.05) was observed for items relating to strongman events and traditional exercises performed during the taper. Only the time at which the Farmer’s Walk was last performed before competition showed poor reliability (ICC=.27). Conclusions We have developed a low cost, self-reported, online retrospective questionnaire, which provided stable and reliable answers for most of the demographic, training, and tapering practice questions. The results of this study support the inferences drawn from the Tapering Practices of Strongman Athletes Study. PMID:29089292

  18. The Influence of Contamination and Cleaning on the Strength of Modular Head Taper Fixation in Total Hip Arthroplasty.

    PubMed

    Krull, Annika; Morlock, Michael M; Bishop, Nicholas E

    2017-10-01

    Intraoperative interface contamination of modular head-stem taper junctions of hip implants can lead to poor fixation strength, causing fretting and crevice corrosion or even stem taper fracture. Careful cleaning before assembly should help to reduce these problems. The purpose of this study was to determine the effect of cleaning (with and without drying) contaminated taper interfaces on the taper fixation strength. Metal or ceramic heads were impacted onto titanium alloy stem tapers with cleaned or contaminated (fat or saline solution) interfaces. The same procedure was performed after cleaning and drying the contaminated interfaces. Pull-off force was used to determine the influence of contamination and cleaning on the taper strength. Pull-off forces after contamination with fat were significantly lower than those for uncontaminated interfaces for both head materials. Pull-off forces after application of saline solution were not significantly different from those for uncontaminated tapers. However, a large variation in taper strength was observed, pull-off forces for cleaned and dried tapers were similar to those for uncontaminated tapers for both head materials. Intraoperative contamination of taper interfaces may be difficult to detect but has a major influence on taper fixation strength. Cleaning of the stem taper with saline solution and drying with gauze directly before assembly allows the taper strength of the pristine components to be achieved. Not drying the taper results in a large variation in pull-off forces, emphasizing that drying is essential for sufficient and reproducible fixation strength. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Dynamic and thermal analysis of high speed tapered roller bearings under combined loading

    NASA Technical Reports Server (NTRS)

    Crecelius, W. J.; Milke, D. R.

    1973-01-01

    The development of a computer program capable of predicting the thermal and kinetic performance of high-speed tapered roller bearings operating with fluid lubrication under applied axial, radial and moment loading (five degrees of freedom) is detailed. Various methods of applying lubrication can be considered as well as changes in bearing internal geometry which occur as the bearing is brought to operating speeds, loads and temperatures.

  20. Smart-phone based computational microscopy using multi-frame contact imaging on a fiber-optic array.

    PubMed

    Navruz, Isa; Coskun, Ahmet F; Wong, Justin; Mohammad, Saqib; Tseng, Derek; Nagi, Richie; Phillips, Stephen; Ozcan, Aydogan

    2013-10-21

    We demonstrate a cellphone based contact microscopy platform, termed Contact Scope, which can image highly dense or connected samples in transmission mode. Weighing approximately 76 grams, this portable and compact microscope is installed on the existing camera unit of a cellphone using an opto-mechanical add-on, where planar samples of interest are placed in contact with the top facet of a tapered fiber-optic array. This glass-based tapered fiber array has ~9 fold higher density of fiber optic cables on its top facet compared to the bottom one and is illuminated by an incoherent light source, e.g., a simple light-emitting-diode (LED). The transmitted light pattern through the object is then sampled by this array of fiber optic cables, delivering a transmission image of the sample onto the other side of the taper, with ~3× magnification in each direction. This magnified image of the object, located at the bottom facet of the fiber array, is then projected onto the CMOS image sensor of the cellphone using two lenses. While keeping the sample and the cellphone camera at a fixed position, the fiber-optic array is then manually rotated with discrete angular increments of e.g., 1-2 degrees. At each angular position of the fiber-optic array, contact images are captured using the cellphone camera, creating a sequence of transmission images for the same sample. These multi-frame images are digitally fused together based on a shift-and-add algorithm through a custom-developed Android application running on the smart-phone, providing the final microscopic image of the sample, visualized through the screen of the phone. This final computation step improves the resolution and also removes spatial artefacts that arise due to non-uniform sampling of the transmission intensity at the fiber optic array surface. We validated the performance of this cellphone based Contact Scope by imaging resolution test charts and blood smears.

  1. Smart-phone based computational microscopy using multi-frame contact imaging on a fiber-optic array

    PubMed Central

    Navruz, Isa; Coskun, Ahmet F.; Wong, Justin; Mohammad, Saqib; Tseng, Derek; Nagi, Richie; Phillips, Stephen; Ozcan, Aydogan

    2013-01-01

    We demonstrate a cellphone based contact microscopy platform, termed Contact Scope, which can image highly dense or connected samples in transmission mode. Weighing approximately 76 grams, this portable and compact microscope is installed on the existing camera unit of a cellphone using an opto-mechanical add-on, where planar samples of interest are placed in contact with the top facet of a tapered fiber-optic array. This glass-based tapered fiber array has ∼9 fold higher density of fiber optic cables on its top facet compared to the bottom one and is illuminated by an incoherent light source, e.g., a simple light-emitting-diode (LED). The transmitted light pattern through the object is then sampled by this array of fiber optic cables, delivering a transmission image of the sample onto the other side of the taper, with ∼3× magnification in each direction. This magnified image of the object, located at the bottom facet of the fiber array, is then projected onto the CMOS image sensor of the cellphone using two lenses. While keeping the sample and the cellphone camera at a fixed position, the fiber-optic array is then manually rotated with discrete angular increments of e.g., 1-2 degrees. At each angular position of the fiber-optic array, contact images are captured using the cellphone camera, creating a sequence of transmission images for the same sample. These multi-frame images are digitally fused together based on a shift-and-add algorithm through a custom-developed Android application running on the smart-phone, providing the final microscopic image of the sample, visualized through the screen of the phone. This final computation step improves the resolution and also gets rid of spatial artefacts that arise due to non-uniform sampling of the transmission intensity at the fiber optic array surface. We validated the performance of this cellphone based Contact Scope by imaging resolution test charts and blood smears. PMID:23939637

  2. Membrane voltage changes in passive dendritic trees: a tapering equivalent cylinder model.

    PubMed

    Poznański, R R

    1988-01-01

    An exponentially tapering equivalent cylinder model is employed in order to approximate the loss of the dendritic trunk parameter observed from anatomical data on apical and basilar dendrites of CA1 and CA3 hippocampal pyramidal neurons. This model allows dendritic trees with a relative paucity of branching to be treated. In particular, terminal branches are not required to end at the same electrotonic distance. The Laplace transform method is used to obtain analytic expressions for the Green's function corresponding to an instantaneous pulse of current injected at a single point along a tapering equivalent cylinder with sealed ends. The time course of the voltage in response to an arbitrary input is computed using the Green's function in a convolution integral. Examples of current input considered are (1) an infinitesimally brief (Dirac delta function) pulse and (2) a step pulse. It is demonstrated that inputs located on a tapering equivalent cylinder are more effective at the soma than identically placed inputs on a nontapering equivalent cylinder. Asymptotic solutions are derived to enable the voltage response behaviour over both relatively short and long time periods to be analysed. Semilogarithmic plots of these solutions provide a basis for estimating the membrane time constant tau m from experimental transients. Transient voltage decrement from a clamped soma reveals that tapering tends to reduce the error associated with inadequate voltage clamping of the dendritic membrane. A formula is derived which shows that tapering tends to increase the estimate of the electrotonic length parameter L.

  3. Simulation and experimental validation of droplet dynamics in microchannels of PEM fuel cells

    NASA Astrophysics Data System (ADS)

    Ashrafi, Moosa; Shams, Mehrzad; Bozorgnezhad, Ali; Ahmadi, Goodarz

    2016-12-01

    In this study, dynamics of droplets in the channels of proton exchange membrane fuel cells with straight and serpentine flow-fields was investigated. Tapered and filleted channels were suggested for the straight and serpentine flow-fields respectively in order to improve water removal in channels. Surface tension and wall adhesion forces were applied by using the volume of fluid method. The hydrophilic walls and hydrophobic gas diffusion layer were considered. The mechanism of droplets movement with different diameters was studied by using the Weber and capillary numbers in simple and tapered straight channels. It was illustrated that the flooding was reduced in tapered channel due to increase of water removal rate, and available reaction sites improved subsequently. In addition, film flow was formed in the tapered channel more than the simple channel, so pressure fluctuation was decreased in the tapered channel. Moreover, the water coverage ratio of hydrophilic tapered surface was more than the simple channel, which enhanced water removal from the channel. The filleted serpentine channel was introduced to improve water removal from the simple serpentine channel. It was shown by observation of the unsteady and time-averaged two-phase pressure drop that in the filleted serpentine channels, the two-phase pressure drop was far less than the simple serpentine channel, and also the accumulation of water droplets in the elbows was less leading to lower pressure fluctuation. The numerical simulation results were validated by experiments.

  4. White light supercontinuum generation in a Y-shaped microstructured tapered fiber pumped at 1064 nm.

    PubMed

    Cascante-Vindas, J; Díez, A; Cruz, J L; Andrés, M V

    2010-07-05

    We report the generation of supercontinuum in a Ge-doped Y-shape tapered fiber pumped at 1064 nm in the ns pump regime. The taper was designed to have long taper transitions and a taper waist with a core diameter of 0.9 mum. The large air-filling fraction and diameter of the air-hole microstructure reduces the confinement loss at long wavelengths so, enabling the extension of the spectrum to longer wavelengths. Along the taper transition the zero-dispersion wavelength decreases as the diameter of the taper becomes smaller. The spectral components generated along the taper transition pump the taper waist, enhancing the generation of short wavelengths. A flat spectrum spanning from 420 nm to 1850 nm is reported.

  5. Efficient Implementation of an Optimal Interpolator for Large Spatial Data Sets

    NASA Technical Reports Server (NTRS)

    Memarsadeghi, Nargess; Mount, David M.

    2007-01-01

    Scattered data interpolation is a problem of interest in numerous areas such as electronic imaging, smooth surface modeling, and computational geometry. Our motivation arises from applications in geology and mining, which often involve large scattered data sets and a demand for high accuracy. The method of choice is ordinary kriging. This is because it is a best unbiased estimator. Unfortunately, this interpolant is computationally very expensive to compute exactly. For n scattered data points, computing the value of a single interpolant involves solving a dense linear system of size roughly n x n. This is infeasible for large n. In practice, kriging is solved approximately by local approaches that are based on considering only a relatively small'number of points that lie close to the query point. There are many problems with this local approach, however. The first is that determining the proper neighborhood size is tricky, and is usually solved by ad hoc methods such as selecting a fixed number of nearest neighbors or all the points lying within a fixed radius. Such fixed neighborhood sizes may not work well for all query points, depending on local density of the point distribution. Local methods also suffer from the problem that the resulting interpolant is not continuous. Meyer showed that while kriging produces smooth continues surfaces, it has zero order continuity along its borders. Thus, at interface boundaries where the neighborhood changes, the interpolant behaves discontinuously. Therefore, it is important to consider and solve the global system for each interpolant. However, solving such large dense systems for each query point is impractical. Recently a more principled approach to approximating kriging has been proposed based on a technique called covariance tapering. The problems arise from the fact that the covariance functions that are used in kriging have global support. Our implementations combine, utilize, and enhance a number of different approaches that have been introduced in literature for solving large linear systems for interpolation of scattered data points. For very large systems, exact methods such as Gaussian elimination are impractical since they require 0(n(exp 3)) time and 0(n(exp 2)) storage. As Billings et al. suggested, we use an iterative approach. In particular, we use the SYMMLQ method, for solving the large but sparse ordinary kriging systems that result from tapering. The main technical issue that need to be overcome in our algorithmic solution is that the points' covariance matrix for kriging should be symmetric positive definite. The goal of tapering is to obtain a sparse approximate representation of the covariance matrix while maintaining its positive definiteness. Furrer et al. used tapering to obtain a sparse linear system of the form Ax = b, where A is the tapered symmetric positive definite covariance matrix. Thus, Cholesky factorization could be used to solve their linear systems. They implemented an efficient sparse Cholesky decomposition method. They also showed if these tapers are used for a limited class of covariance models, the solution of the system converges to the solution of the original system. Matrix A in the ordinary kriging system, while symmetric, is not positive definite. Thus, their approach is not applicable to the ordinary kriging system. Therefore, we use tapering only to obtain a sparse linear system. Then, we use SYMMLQ to solve the ordinary kriging system. We show that solving large kriging systems becomes practical via tapering and iterative methods, and results in lower estimation errors compared to traditional local approaches, and significant memory savings compared to the original global system. We also developed a more efficient variant of the sparse SYMMLQ method for large ordinary kriging systems. This approach adaptively finds the correct local neighborhood for each query point in the interpolation process.

  6. A novel method to fabricate silicon tubular gratings with broadband antireflection and super-hydrophobicity.

    PubMed

    Gao, Yang; Shi, Tielin; Tan, Xianhua; Liao, Guanglan

    2014-06-01

    We have developed a novel method to fabricate micro/nano structure based on the coherent diffraction lithography, and acquired periodic silicon tubular gratings with deep nano-scale tapered profiles at the top part. The optical properties of these tubular gratings were similar to an effective gradient-index antireflective surface, resulting in a broadband antireflective combining super-hydrophobic behavior. The mechanism of the method was simulated by rigorous coupled wave analysis algorithms. Then coherent diffraction lithography by use of suitable mask, in which periodic micro-scale circular opaque patters were distributed, was realized on the traditional aligner. Due to coherent diffraction, we obtained enough light intensity for photoresist exposure under the center of the opaque area in the mask together with transparent areas. The tapered line profiles and hollow photoresist gratings over large areas could be fabricated on the silicon wafer after development. The dry etching process was carried out, and high aspect ratio silicon tubular gratings with deep tapered profiles at the top were fabricated. The optical property and wettability of the structure were verified, proving that the proposed method and obtained micro/nano structure provide application potential in the future.

  7. Moment method analysis of linearly tapered slot antennas: Low loss components for switched beam radiometers

    NASA Technical Reports Server (NTRS)

    Koeksal, Adnan; Trew, Robert J.; Kauffman, J. Frank

    1992-01-01

    A Moment Method Model for the radiation pattern characterization of single Linearly Tapered Slot Antennas (LTSA) in air or on a dielectric substrate is developed. This characterization consists of: (1) finding the radiated far-fields of the antenna; (2) determining the E-Plane and H-Plane beamwidths and sidelobe levels; and (3) determining the D-Plane beamwidth and cross polarization levels, as antenna parameters length, height, taper angle, substrate thickness, and the relative substrate permittivity vary. The LTSA geometry does not lend itself to analytical solution with the given parameter ranges. Therefore, a computer modeling scheme and a code are necessary to analyze the problem. This necessity imposes some further objectives or requirements on the solution method (modeling) and tool (computer code). These may be listed as follows: (1) a good approximation to the real antenna geometry; and (2) feasible computer storage and time requirements. According to these requirements, the work is concentrated on the development of efficient modeling schemes for these type of problems and on reducing the central processing unit (CPU) time required from the computer code. A Method of Moments (MoM) code is developed for the analysis of LTSA's within the parameter ranges given.

  8. New results on equatorial thermospheric winds and temperatures from Ethiopia, Africa

    NASA Astrophysics Data System (ADS)

    Tesema, Fasil; Mesquita, Rafael; Meriwether, John; Damtie, Baylie; Nigussie, Melessew; Makela, Jonathan; Fisher, Daniel; Harding, Brian; Yizengaw, Endawoke; Sanders, Samuel

    2017-03-01

    Measurements of equatorial thermospheric winds, temperatures, and 630 nm relative intensities were obtained using an imaging Fabry-Perot interferometer (FPI), which was recently deployed at Bahir Dar University in Ethiopia (11.6° N, 37.4° E, 3.7° N magnetic). The results obtained in this study cover 6 months (53 nights of useable data) between November 2015 and April 2016. The monthly-averaged values, which include local winter and equinox seasons, show the magnitude of the maximum monthly-averaged zonal wind is typically within the range of 70 to 90 ms-1 and is eastward between 19:00 and 21:00 LT. Compared to prior studies of the equatorial thermospheric wind for this local time period, the magnitude is considerably weaker as compared to the maximum zonal wind speed observed in the Peruvian sector but comparable to Brazilian FPI results. During the early evening, the meridional wind speeds are 30 to 50 ms-1 poleward during the winter months and 10 to 25 ms-1 equatorward in the equinox months. The direction of the poleward wind during the winter months is believed to be mainly caused by the existence of the interhemispheric wind flow from the summer to winter hemispheres. An equatorial wind surge is observed later in the evening and is shifted to later local times during the winter months and to earlier local times during the equinox months. Significant night-to-night variations are also observed in the maximum speed of both zonal and meridional winds. The temperature observations show the midnight temperature maximum (MTM) to be generally present between 00:30 and 02:00 LT. The amplitude of the MTM was ˜ 110 K in January 2016 with values smaller than this in the other months. The local time difference between the appearance of the MTM and a pre-midnight equatorial wind was generally 60 to 180 min. A meridional wind reversal was also observed after the appearance of the MTM (after 02:00 LT). Climatological models, HWM14 and MSIS-00, were compared to the observations and the HWM14 model generally predicted the zonal wind observations well with the exception of higher model values by 25 ms-1 in the winter months. The HWM14 model meridional wind showed generally good agreement with the observations. Finally, the MSIS-00 model overestimated the temperature by 50 to 75 K during the early evening hours of local winter months. Otherwise, the agreement was generally good, although, in line with prior studies, the model failed to reproduce the MTM peak for any of the 6 months compared with the FPI data.

  9. Highly stable multi-wavelength erbium-doped fiber linear laser based on modal interference

    NASA Astrophysics Data System (ADS)

    Herrera-Piad, L. A.; Jauregui-Vazquez, D.; Lopez-Dieguez, Y.; Estudillo-Ayala, J. M.; Hernandez-Garcia, J. C.; Sierra-Hernandez, J. M.; Bianchetti, M.; Rojas-Laguna, R.

    2018-03-01

    We report a linear fiber laser cavity based on an all-fiber Fabry-Perot interferometer and bi-tapered optical fiber for multi-wavelength emission generation. Curvature and strain are used to operate the laser system and the number of lines as well, the emission regions are stronger related to the physical effect applied, due to the phase alteration between the multiple fiber optic modes involved. The original laser emissions present zero wavelength variations, minimal power fluctuations and small spacing mode (1 nm). Additionally, a nonlinear fiber was employed trying to improve the performance of the multiple lasing lines. This system offers a low implementation cost, compactness and good laser parameters.

  10. TU-F-CAMPUS-I-04: Head-Only Asymmetric Gradient System Evaluation: ACR Image Quality and Acoustic Noise

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weavers, P; Shu, Y; Tao, S

    Purpose: A high-performance head-only magnetic resonance imaging gradient system with an acquisition volume of 26 cm employing an asymmetric design for the transverse coils has been developed. It is able to reach a magnitude of 85 mT/m at a slew rate of 700 T/m/s, but operated at 80 mT/m and 500 T/m/s for this test. A challenge resulting from this asymmetric design is that the gradient nonlinearly exhibits both odd- and even-ordered terms, and as the full imaging field of view is often used, the nonlinearity is pronounced. The purpose of this work is to show the system can producemore » clinically useful images after an on-site gradient nonlinearity calibration and correction, and show that acoustic noise levels fall within non-significant risk (NSR) limits for standard clinical pulse sequences. Methods: The head-only gradient system was inserted into a standard 3T wide-bore scanner without acoustic damping. The ACR phantom was scanned in an 8-channel receive-only head coil and the standard American College of Radiology (ACR) MRI quality control (QC) test was performed. Acoustic noise levels were measured for several standard pulse sequences. Results: Images acquired with the head-only gradient system passed all ACR MR image quality tests; Both even and odd-order gradient distortion correction terms were required for the asymmetric gradients to pass. Acoustic noise measurements were within FDA NSR guidelines of 99 dBA (with assumed 20 dBA hearing protection) A-weighted and 140 dB for peak for all but one sequence. Note the gradient system was installed without any shroud or acoustic batting. We expect final system integration to greatly reduce noise experienced by the patient. Conclusion: A high-performance head-only asymmetric gradient system operating at 80 mT/m and 500 T/m/s conforms to FDA acoustic noise limits in all but one case, and passes all the ACR MR image quality control tests. This work was supported in part by the NIH grant 5R01EB010065.« less

  11. Effect of Patency File on Transportation and Curve Straightening in Canal Preparation with ProTaper System

    PubMed Central

    Hasheminia, Seyed Mohsen

    2013-01-01

    The aim of this ex vivo study was to evaluate the effect of using a patency file on apical transportation and curve straightening during canal instrumentation with the ProTaper rotary system. Seventy permanent mandibular first molars with mesiobuccal canals, measuring 18–23 mm in length and with a 25–40° curvature (according to the Schneider method), were selected. The working lengths were determined and the teeth were mounted and divided into two experimental groups: (A) prepared by the ProTaper system without using a patency file (n = 35) and (B) prepared by the ProTaper system using a patency file (n = 35). Radiographs taken before and after the preparation were imported into Photoshop software and the apical transportation, and curve straightening were measured. Data were analyzed using independent t-test. Partial correlation analysis was performed to evaluate the relationship between the initial curvature, transportation, and curve straightening (α = 0.05). Using a patency file during canal preparation significantly decreased both apical transportation and curve straightening (P < 0.001). There were significant relationships between the angle of curvature, transportation and curve straightening in pairs (P < 0.001). Apical patency is recommended during root canal preparation with the ProTaper rotary system. PMID:24159390

  12. Effect of Patency File on Transportation and Curve Straightening in Canal Preparation with ProTaper System.

    PubMed

    Hasheminia, Seyed Mohsen; Farhadi, Nastaran; Shokraneh, Ali

    2013-01-01

    The aim of this ex vivo study was to evaluate the effect of using a patency file on apical transportation and curve straightening during canal instrumentation with the ProTaper rotary system. Seventy permanent mandibular first molars with mesiobuccal canals, measuring 18-23 mm in length and with a 25-40° curvature (according to the Schneider method), were selected. The working lengths were determined and the teeth were mounted and divided into two experimental groups: (A) prepared by the ProTaper system without using a patency file (n = 35) and (B) prepared by the ProTaper system using a patency file (n = 35). Radiographs taken before and after the preparation were imported into Photoshop software and the apical transportation, and curve straightening were measured. Data were analyzed using independent t-test. Partial correlation analysis was performed to evaluate the relationship between the initial curvature, transportation, and curve straightening (α = 0.05). Using a patency file during canal preparation significantly decreased both apical transportation and curve straightening (P < 0.001). There were significant relationships between the angle of curvature, transportation and curve straightening in pairs (P < 0.001). Apical patency is recommended during root canal preparation with the ProTaper rotary system.

  13. Comparison of the cleaning capacity of Mtwo and Pro Taper rotary systems and manual instruments in primary teeth

    PubMed Central

    Azar, Mohammad Reza; Safi, Laya; Nikaein, Afshin

    2012-01-01

    Background: Root canal cleaning is an important step in endodontic therapy. In order to develop better techniques, a new generation of endodontic instruments has been designed. The aim of this study was to compare the effectiveness of manual K-files (Mani Co, Tokyo, Japan) and two rotary systems–Mtwo (Dentsply-Maillefer, Ballaigues, Switzerland) and ProTaper (VDW, Munich, Germany)–for root canal preparation in primary molars. Materials and Methods: India ink was injected to 160 mesiobuccal and distal root canals of mandibular primary molars. The teeth were randomly divided into three experimental groups and one control group. In each experimental group, either manual instruments (K-files) or rotary instruments (Mtwo or ProTaper) were used to prepare root canals. After cleaning the canals and clearing the teeth, ink removal was evaluated with a stereomicroscope. Statistical analysis was done with Kruskal–Wallis and Friedman tests. Results: There were no significant differences in cleaning efficiency between manual and rotary instruments. Only ProTaper files performed significantly better in the coronal and middle thirds than in the apical third of the root canal. Conclusion: Manual K-files and the Mtwo and ProTaper rotary systems showed equally acceptable cleaning ability in primary molar root canals. PMID:22623929

  14. Generation of 3.5 W of diffraction-limited green light from SHG of a single tapered diode laser in a cascade of nonlinear crystals

    NASA Astrophysics Data System (ADS)

    Hansen, Anders K.; Jensen, Ole B.; Sumpf, Bernd; Erbert, Götz; Unterhuber, Angelika; Drexler, Wolfgang; Andersen, Peter E.; Petersen, Paul Michael

    2014-02-01

    Many applications, e.g., within biomedicine stand to benefit greatly from the development of diode laser-based multi- Watt efficient compact green laser sources. The low power of existing diode lasers in the green area (about 100 mW) means that the most promising approach remains nonlinear frequency conversion of infrared tapered diode lasers. Here, we describe the generation of 3.5 W of diffraction-limited green light from SHG of a single tapered diode laser, itself yielding 10 W at 1063 nm. This SHG is performed in single pass through a cascade of two PPMgO:LN crystals with re-focusing and dispersion compensating optics between the two nonlinear crystals. In the low-power limit, such a cascade of two crystals has the theoretical potential for generation of four times as much power as a single crystal without adding significantly to the complexity of the system. The experimentally achieved power of 3.5 W corresponds to a power enhancement greater than 2 compared to SHG in each of the crystals individually and is the highest visible output power generated by frequency conversion of a single diode laser. Such laser sources provide the necessary pump power for biophotonics applications, such as optical coherence tomography or multimodal imaging devices, e.g., FTCARS-OCT, based on a strongly pumped ultrafast Ti:Sapphire laser.

  15. Adjunctive Counseling During Brief and Extended Buprenorphine-Naloxone Treatment for Prescription Opioid Dependence

    PubMed Central

    Weiss, Roger D.; Potter, Jennifer Sharpe; Fiellin, David A.; Byrne, Marilyn; Connery, Hilary S.; Dickinson, William; Gardin, John; Griffin, Margaret L.; Gourevitch, Marc N.; Haller, Deborah L.; Hasson, Albert L.; Huang, Zhen; Jacobs, Petra; Kosinski, Andrzej S.; Lindblad, Robert; McCance-Katz, Elinore F.; Provost, Scott E.; Selzer, Jeffrey; Somoza, Eugene C.; Sonne, Susan C.; Ling, Walter

    2012-01-01

    Context No randomized trials have examined treatments for prescription opioid dependence, despite its increasing prevalence. Objective To evaluate the efficacy of brief and extended buprenorphine-naloxone treatment, with different counseling intensities, for patients dependent upon prescription opioids. Setting, Participants 653 treatment-seeking outpatients dependent on prescription opioids, at 10 U.S. sites from June 2006-July 2009. Design Multi-site, randomized clinical trial, using a two-phase adaptive treatment research design. Brief treatment (Phase 1) included 2-week buprenorphine-naloxone stabilization, 2-week taper, and 8-week post-medication follow-up. Patients with successful opioid use outcomes exited the study; unsuccessful patients entered Phase 2: extended (12-week) buprenorphine-naloxone treatment, 4-week taper, and 8-week post-medication follow-up. Main outcome measures Pre-defined “successful outcome” in each phase: composite measures indicating minimal or no opioid use, based on urine-confirmed self-reports. Interventions In both phases, patients were randomized to Standard Medical Management (SMM) or SMM+Opioid Drug Counseling (ODC); all received buprenorphine-naloxone. Results During Phase 1, only 6.6% (43/653) of patients had successful outcomes, with no difference between the SMM and SMM+ODC. In contrast, 49.2% (177/360) attained successful outcomes in Phase 2 during extended buprenorphine-naloxone treatment (week 12), with no difference between counseling conditions. Success rates 8 weeks after completing the buprenorphine-naloxone taper (Phase 2, week 24) dropped sharply to 8.6% (31/360), again with no counseling difference. In secondary analyses, successful Phase 2 outcomes were far more common while taking buprenorphine-naloxone than 8 weeks post-taper (49.2% (177/360) vs. 8.6% (31/360), p<0.001). Chronic pain did not affect opioid use outcomes; a history of ever using heroin was associated with lower Phase 2 success rates while taking buprenorphine-naloxone. Conclusions Prescription opioid-dependent patients are most likely to reduce opioid use during buprenorphine-naloxone treatment; if tapered off buprenorphine-naloxone, even after 12 weeks of treatment, the likelihood of unsuccessful outcome is extremely high, even among patients receiving counseling in addition to medical management. Trial Registration ClinicalTrials.gov number NCT00316277 PMID:22065255

  16. Scattering apodizer for laser beams

    DOEpatents

    Summers, Mark A.; Hagen, Wilhelm F.; Boyd, Robert D.

    1985-01-01

    A method is disclosed for apodizing a laser beam to smooth out the production of diffraction peaks due to optical discontinuities in the path of the laser beam, such method comprising introduction of a pattern of scattering elements for reducing the peak intensity in the region of such optical discontinuities, such pattern having smoothly tapering boundaries in which the distribution density of the scattering elements is tapered gradually to produce small gradients in the distribution density, such pattern of scattering elements being effective to reduce and smooth out the diffraction effects which would otherwise be produced. The apodizer pattern may be produced by selectively blasting a surface of a transparent member with fine abrasive particles to produce a multitude of minute pits. In one embodiment, a scattering apodizer pattern is employed to overcome diffraction patterns in a multiple element crystal array for harmonic conversion of a laser beam. The interstices and the supporting grid between the crystal elements are obscured by the gradually tapered apodizer pattern of scattering elements.

  17. In vitro Comparison of Apical Debris Extrusion Using Rotary and Reciprocating Systems in Severely Curved Root Canals

    PubMed Central

    Delvarani, Abbas; Mohammadzadeh Akhlaghi, Nahid; Aminirad, Raana; Tour Savadkouhi, Sohrab; Vahdati, Seyed Aliakbar

    2017-01-01

    Introduction: The aim of this in vitro study was to compare the amount of apically extruded debris after root canal preparation using rotary and reciprocating systems in severely curved root canals. Methods and Materials: Thirty six extracted human mandibular first molars with 25-35° curvature in their mesiobuccal (MB) canal (according to Schneider’s method) were cleaned and shaped with ProTaper and WaveOne systems. The extruded debris was collected and their net weight was calculated. To compare the efficiency of the two systems, the operation time was also measured. The data were analyzed with t-test. Results: The amount of extruded debris in WaveOne group was significantly greater in comparison with ProTaper group (26%). The operating time for ProTaper was however, significantly longer than WaveOne. Conclusion: Both root preparation systems caused some degree of debris extrusion through the apical foramen. However, this amount was greater in WaveOne instruments. PMID:28179921

  18. Scattering apodizer for laser beams

    DOEpatents

    Summers, M.A.; Hagen, W.F.; Boyd, R.D.

    1984-01-01

    A method is disclosed for apodizing a laser beam to smooth out the production of diffraction peaks due to optical discontinuities in the path of the laser beam, such method comprising introduction of a pattern of scattering elements for reducing the peak intensity in the region of such optical discontinuities, such pattern having smoothly tapering boundaries in which the distribution density of the scattering elements is tapered gradually to produce small gradients in the distribution density, such pattern of scattering elements being effective to reduce and smooth out the diffraction effects which would otherwise be produced. The apodizer pattern may be produced by selectively blasting a surface of a transparent member with fine abrasive particles to produce a multitude of minute pits. In one embodiment, a scattering apodizer pattern is employed to overcome diffraction patterns in a multiple element crystal array for harmonic conversion of a laser beam. The interstices and the supporting grid between the crystal elements are obscured by the gradually tapered apodizer pattern of scattering elements.

  19. Does Surface Topography Play a Role in Taper Damage in Head-neck Modular Junctions?

    PubMed

    Pourzal, Robin; Hall, Deborah J; Ha, Nguyen Q; Urban, Robert M; Levine, Brett R; Jacobs, Joshua J; Lundberg, Hannah J

    2016-10-01

    There are increasing reports of total hip arthroplasty failure subsequent to modular taper junction corrosion. The surfaces of tapers are machined to have circumferential machining marks, resulting in a surface topography of alternating peaks and valleys on the scale of micrometers. It is unclear if the geometry of this machined surface topography influences the degree of fretting and corrosion damage present on modular taper junctions or if there are differences between modular taper junction material couples. (1) What are the differences in damage score and surface topography between CoCr/CoCr and CoCr/Ti modular junctions? (2) How are initial surface topography, flexural rigidity, taper angle mismatch, and time in situ related to visual taper damage scores for CoCr/CoCr couples? (3) How are initial surface topography, flexural rigidity, taper angle mismatch, and time in situ related to visual taper damage scores for CoCr/Ti couples? Damage on stem and head tapers was evaluated with a modified Goldberg score. Differences in damage scores were determined between a group of 140 CoCr/CoCr couples and 129 CoCr/Ti couples using a chi-square test. For a subgroup of 70 retrievals, selected at random, we measured five variables, including initial stem taper machining mark height and spacing, initial head taper roughness, flexural rigidity, and taper angle mismatch. All retrievals were obtained at revision surgeries. None were retrieved as a result of metal-on-metal failures or were recalled implants. Components were chosen so there was a comparable number of each material couple and damage score. Machining marks around the circumference of the tapers were measured using white light interferometry to characterize the initial stem taper surface topography in terms of the height of and spacing between machining mark peaks as well as initial head taper roughness. The taper angle mismatch was assessed with a coordinate measuring machine. Flexural rigidity was determined based on measurements of gross taper dimensions and material properties. Differences of median or mean values of all variables between material couples were determined (Wilcoxon rank-sum tests and t-tests). The effect of all five variables along with time in situ on stem and head taper damage scores was tested with a multiple regression model. With 70 retrievals, a statistical power of 0.8 could be achieved for the model. Damage scores were different between CoCr/CoCr and CoCr/Ti modular taper junction material couples. CoCr/CoCr stem tapers were less likely to be mildly damaged (11%, p = 0.006) but more likely to be severely damaged (4%, p = 0.02) than CoCr/Ti stem tapers (28% and 1%, respectively). CoCr/CoCr couples were less likely to have moderately worn head tapers (7% versus 17%, p = 0.003). Stem taper machining mark height and spacing and head taper roughness were 11 (SD 3), 185 (SD 46), and 0.57 (SD 0.5) for CoCr/CoCr couples and 10 (SD 3), 170 (SD 56), and 0.64 (SD 0.4) for CoCr/Ti couples, respectively. There was no difference (p = 0.09, p = 0.1, p = 0.16, respectively) for either factor between material couples. Larger stem taper machining mark heights (p = 0.001) were associated with lower stem taper damage scores, and time in situ (p = 0.006) was associated with higher stem taper damage scores for CoCr/CoCr material couples. Stem taper machining marks that had higher peaks resulted in slower damage progression over time. For CoCr/Ti material couples, head taper roughness was associated with higher stem (p = 0.001) and head taper (p = 0.003) damage scores, and stem taper machining mark height, but not time in situ, was associated with lower stem taper damage scores (p = 0.007). Stem taper surface topography was related to damage scores on retrieved head-neck modular junctions; however, it affected CoCr/CoCr and CoCr/Ti couples differently. A taper topography of circumferential machining marks with higher peaks appears to enable slower damage progression and, subsequently, a reduction of the reported release of corrosion products. This may be of interest to implant designers and manufacturers in an effort to reduce the effects of metal release from modular femoral components.

  20. Method of forming shrink-fit compression seal

    NASA Technical Reports Server (NTRS)

    Podgorski, T. J. (Inventor)

    1977-01-01

    A method for making a glass-to-metal seal is described. A domed metal enclosure having a machined seal ring is fitted to a glass post machined to a slight taper and to a desired surface finish. The metal part is then heated by induction in a vacuum. As the metal part heats and expands relative to the glass post, the metal seal ring, possessing a higher coefficient of expansion than the glass post, slides down the tapered post. Upon cooling, the seal ring crushes against the glass post forming the seal. The method results in a glass-to-metal seal possessing extremely good leak resistance, while the parts are kept clean and free of the contaminants.

  1. Application of fiber tapers in astronomy

    NASA Astrophysics Data System (ADS)

    Marcel, Jaclyn; Haynes, Roger; Bland-Hawthorn, Joss

    2006-06-01

    Fiber tapers have the potential to significantly advance instrument technology into the realm of fully integrated optical systems. Our initial investigation was directed at the use of fiber tapers as f-ratio transformation devices. Using a technique developed for testing focal ratio degradation (FRD), a collimated light source was injected at different angles into various fiber taper samples and the far-field profile of the fiber output was observed. We compare the FRD present in the optical fiber tapers with conventional fibers and determine how effectively fiber tapers perform as image converters. We demonstrate that while silica fiber tapers may have slightly more intrinsic FRD than conventional fibers they still show promise as adiabatic mode transformers and are worth investigating further for their potential use in astronomical instruments. In this paper we present a brief review of the current status of fiber tapers with particular focus on the astronomical applications. We demonstrate the conservation of etendue in the taper transformation process and present the experimental results for a number of different taper profiles and manufacturers.

  2. The efficacy of the self-adjusting file and ProTaper for removal of calcium hydroxide from root canals

    PubMed Central

    FARIA, Gisele; KUGA, Milton Carlos; RUY, Alessandra Camila; ARANDA-GARCIA, Arturo Javier; BONETTI-FILHO, Idomeo; GUERREIRO-TANOMARU, Juliane Maria; LEONARDO, Renato Toledo

    2013-01-01

    Objective The goal of this study was to evaluate the efficacy of the Self-Adjusting File (SAF) and ProTaper for removing calcium hydroxide [Ca(OH)2] from root canals. Material and Methods Thirty-six human mandibular incisors were instrumented with the ProTaper system up to instrument F2 and filled with a Ca(OH)2-based dressing. After 7 days, specimens were distributed in two groups (n=15) according to the method of Ca(OH)2 removal. Group I (SAF) was irrigated with 5 mL of NaOCl and SAF was used for 30 seconds under constant irrigation with 5 mL of NaOCl using the Vatea irrigation device, followed by irrigation with 3 mL of EDTA and 5 mL of NaOCl. Group II (ProTaper) was irrigated with 5 mL of NaOCl, the F2 instrument was used for 30 seconds, followed by irrigation with 5 mL of NaOCl, 3 mL of EDTA, and 5 mL of NaOCl. In 3 teeth Ca(OH)2 was not removed (positive control) and in 3 teeth canals were not filled with Ca(OH)2 (negative control). Teeth were sectioned and prepared for the scanning electron microscopy. The amounts of residual Ca(OH)2 were evaluated in the middle and apical thirds using a 5-score system. Results None of the techniques completely removed the Ca(OH)2 dressing. No difference was observed between SAF and ProTaper in removing Ca(OH)2 in the middle (P=0.11) and the apical (P=0.23) thirds. Conclusion The SAF system showed similar efficacy to rotary instrument for removal of Ca(OH)2 from mandibular incisor root canals. PMID:24037074

  3. Ultra-long-period fiber grating cascaded to a knob-taper for simultaneous measurement of strain and temperature

    NASA Astrophysics Data System (ADS)

    Tong, Chengguo; Chen, Xudong; Zhou, Yu; He, Jiang; Yang, Wenlei; Geng, Tao; Sun, Weimin; Yuan, Libo

    2018-06-01

    This study presents a simple Mach-Zehnder interferometer (MZI) to obtain the bimodal characteristics that realize simultaneous measurement of strain and temperature through cascading an ultra-long-period fiber grating and a knob-shaped taper. We obtain the multi-dip feature from the MZI, and the Dips 2 and 5 are selected from 11 interference dips. Experimental results indicated that the wavelength sensitivities of Dips 2 and 5 are - 0.54 nm mɛ-1 and 0.058 nm °C-1, and - 0.53 nm mɛ-1 and 0.055 nm °C-1 to strain and temperature, respectively. The depth sensitivities are - 3.3 dB mɛ- 1, - 0.015 dB °C-1 and -5.8 dB mɛ-1, and 0.06 dB °C-1 for Dips 2 and 5, respectively. It is concluded that the proposed structure is suitable for simultaneous strain and temperature measurements.

  4. Ultra-long-period fiber grating cascaded to a knob-taper for simultaneous measurement of strain and temperature

    NASA Astrophysics Data System (ADS)

    Tong, Chengguo; Chen, Xudong; Zhou, Yu; He, Jiang; Yang, Wenlei; Geng, Tao; Sun, Weimin; Yuan, Libo

    2018-03-01

    This study presents a simple Mach-Zehnder interferometer (MZI) to obtain the bimodal characteristics that realize simultaneous measurement of strain and temperature through cascading an ultra-long-period fiber grating and a knob-shaped taper. We obtain the multi-dip feature from the MZI, and the Dips 2 and 5 are selected from 11 interference dips. Experimental results indicated that the wavelength sensitivities of Dips 2 and 5 are - 0.54 nm mɛ-1 and 0.058 nm °C-1, and - 0.53 nm mɛ-1 and 0.055 nm °C-1 to strain and temperature, respectively. The depth sensitivities are - 3.3 dB mɛ- 1, - 0.015 dB °C-1 and -5.8 dB mɛ-1, and 0.06 dB °C-1 for Dips 2 and 5, respectively. It is concluded that the proposed structure is suitable for simultaneous strain and temperature measurements.

  5. Experimental Investigation of Superradiance in a Tapered Free-Electron Laser Amplifier

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hidaka, Y.; She, Y.; Murphy, J.B.

    2011-03-28

    We report experimental studies of the effect of undulator tapering on superradiance in a single-pass high-gain free-electron laser (FEL) amplifier. The experiments were performed at the Source Development Laboratory (SDL) of National Synchrotron Light Source (NSLS). Efficiency was nearly tripled with tapering. Both the temporal and spectral properties of the superradiant FEL along the uniform and tapered undulator were experimentally characterized using frequency-resolved optical gating (FROG) images. Numerical studies predicted pulse broadening and spectral cleaning by undulator tapering Pulse broadening was experimentally verified. However, spectral cleanliness degraded with tapering. We have performed first experiments with a tapered undulator and amore » short seed laser pulse. Pulse broadening with tapering expected from simulations was experimentally confirmed. However, the experimentally obtained spectra degraded with tapering, whereas the simulations predicted improvement. A further numerical study is under way to resolve this issue.« less

  6. Where science meets practice: Olympic coaches' crafting of the tapering process.

    PubMed

    Ritchie, Darren; Allen, Justine B; Kirkland, Andrew

    2018-05-01

    Although there is research providing physiologically-based guidance for the content of the taper, this study was the first to examine how coaches actually implement the taper. The purpose of this study was to examine the taper planning and implementation processes of successful Olympic coaches leading up to major competitions and how they learned about tapering. Seven track and field coaches participated in semi-structured interviews exploring their tapering processes. To be considered for inclusion, coaches were required to have coached one or more athletes to an Olympic or Paralympic medal. Through a process of axial and open coding interview transcripts were analysed and lower and higher order themes developed describing the coaches' tapering processes. Our findings indicate that the strategies employed to achieve the desired physiological adaptions of the taper were consistent with research (e.g., reduction in volume whilst maintaining intensity and frequency). However, our findings also suggest that tapering is far from a straight forward "textbook" process. The taper was not restricted to physiological outcomes with coaches considering athletes' psychological as well as physical state. Coaches also involved the athlete in the process, adapted the taper to the athlete, continually monitored its progress, and adapted it further as required.

  7. Disparity Implications of the Medicare MTM Eligibility Criteria: A Literature Review

    PubMed Central

    Munshi, Kiraat D.; Shih, Ya-Chen Tina; Brown, Lawrence M.; Dagogo-Jack, Samuel; Wan, Jim Y.; Wang, Junling

    2013-01-01

    Summary The emphasis on eliminating racial and ethnic disparities in health care has received national attention, with various policy initiatives addressing this problem and proposing solutions. However, in the current economic era requiring tight monetary constraints, emphasis is increasingly being placed on economic efficiency, which often conflicts with the equality doctrine upon which many policies have been framed. Our review aims to highlight the disparity implications of one such policy provision—the predominantly utilization-based eligibility criteria for medication therapy management (MTM) services under Medicare Part D—by identifying studies that have documented racial and ethnic disparities in health status and the use of and spending on prescription medications. Future design and evaluation of various regulations and legislations employing utilization-based eligibility criteria must use caution in order to strike an equity-efficiency balance. PMID:23570431

  8. Geologic Mapping of MTM -30247, -35247 and -40247 Quadrangles, Reull Vallis Region, Mars

    NASA Technical Reports Server (NTRS)

    Mest, S. C.; Crown, D. A.

    2009-01-01

    Geologic mapping of MTM -30247, -35247, and -40247 quadrangles is being used to characterize Reull Vallis (RV) and to determine the history of the eastern Hellas region of Mars. Studies of RV examine the roles and timing of volatile-driven erosional and depositional processes and provide constraints on potential associated climatic changes. This study complements earlier investigations of the eastern Hellas region, including regional analyses [1-6], mapping studies of circum-Hellas canyons [7-10], and volcanic studies of Hadriaca and Tyrrhena Paterae [11-13]. Key scientific objectives include 1) characterizing RV in its "fluvial zone," 2) analysis of channels in the surrounding plains and potential connections to and interactions with RV, 3) examining young, presumably sedimentary plains along RV, and 4) determining the nature of the connection between the segments of RV.

  9. Medication therapy management and complex patients with disability: a randomized controlled trial.

    PubMed

    Chrischilles, Elizabeth A; Doucette, William; Farris, Karen; Lindgren, Scott; Gryzlak, Brian; Rubenstein, Linda; Youland, Kelly; Wallace, Robert B

    2014-02-01

    Drug therapy problems, adverse drug events (ADEs), and symptom burden are high among adults with disabilities. To compare the effects of a modified medication therapy management (MTM) program within a self-efficacy workshop versus the workshop alone or usual care on symptom burden among adults with activity limitations. Three-group randomized controlled trial among adults (age 40 and older) with self-reported activity limitations in community practice. 8 weekly Living Well With a Disability (LWD) 2-hour workshop sessions with and without a collaborative medication management (CMM) module. mean number of moderate to very severe symptoms from a list of 11 physical and mental symptoms. Process measures: changes in medication regimens and self-reported ADEs. general linear mixed models (continuous outcomes) and generalized estimating equations (categorical outcomes). Participants had high symptom burden, low physical health, and took many medications. There was a significant increase in ADE reporting in the LWD + CMM group relative to the other 2 groups (Study group × Time P = .014), and there were significantly more changes in medication regimens in the LWD + CMM group (P = .013 LWD only vs LWD + CMM). The oldest third of participants had significantly fewer mean symptoms but received more intense CMM. There was no difference between the LWD-only, LWD + CMM, and usual care groups in symptom burden over time. Pharmacist MTM practices and MTM guidelines may need to be modified to affect symptom burden in a population with physical activity limitations.

  10. Patient-centered health care using pharmacist-delivered medication therapy management in rural Mississippi.

    PubMed

    Ross, Leigh Ann; Bloodworth, Lauren S

    2012-01-01

    To describe and provide preliminary clinical and economic outcomes from a pharmacist-delivered patient-centered health care (PCHC) model implemented in the Mississippi Delta. Mississippi between July 2008 and June 2010. 13 community pharmacies in nine Mississippi Delta counties. This PCHC model implements a comprehensive medication therapy management (MTM) program with pharmacist training, individualized patient encounters and group education, provider outreach, integration of pharmacists into health information technology, and on-site support in community pharmacies in a medically underserved region with a large burden of chronic disease and health disparities. The program also expands on traditional MTM services through initiatives in health literacy/cultural competency and efforts to increase the provider network and improve access to care. Criteria-based clinical outcomes, quality indicator reports, cost avoidance. PCHC services have been implemented in 13 pharmacies in nine counties in this underserved region, and 78 pharmacists and 177 students have completed the American Pharmacists Association's MTM Certificate Training Program. Preliminary data from 468 patients showed 681 encounters in which 1,471 drug therapy problems were identified and resolved. Preliminary data for clinical indicators and economic outcome measures are trending in a positive direction. Preliminary data analyses suggest that pharmacist-provided PCHC is beneficial and has the potential to be replicated in similar rural communities that are plagued with chronic disease and traditional primary care provider shortages. This effort aligns with national priorities to reduce medication errors, improve health outcomes, and reduce health care costs in underserved communities.

  11. Phosphatidylinositol 3-kinase inhibition restores Ca2+ release defects and prolongs survival in myotubularin-deficient mice

    PubMed Central

    Kutchukian, Candice; Lo Scrudato, Mirella; Tourneur, Yves; Poulard, Karine; Vignaud, Alban; Berthier, Christine; Allard, Bruno; Lawlor, Michael W.; Buj-Bello, Ana; Jacquemond, Vincent

    2016-01-01

    Mutations in the gene encoding the phosphoinositide 3-phosphatase myotubularin (MTM1) are responsible for a pediatric disease of skeletal muscle named myotubular myopathy (XLMTM). Muscle fibers from MTM1-deficient mice present defects in excitation–contraction (EC) coupling likely responsible for the disease-associated fatal muscle weakness. However, the mechanism leading to EC coupling failure remains unclear. During normal skeletal muscle EC coupling, transverse (t) tubule depolarization triggers sarcoplasmic reticulum (SR) Ca2+ release through ryanodine receptor channels gated by conformational coupling with the t-tubule voltage-sensing dihydropyridine receptors. We report that MTM1 deficiency is associated with a 60% depression of global SR Ca2+ release over the full range of voltage sensitivity of EC coupling. SR Ca2+ release in the diseased fibers is also slower than in normal fibers, or delayed following voltage activation, consistent with the contribution of Ca2+-gated ryanodine receptors to EC coupling. In addition, we found that SR Ca2+ release is spatially heterogeneous within myotubularin-deficient muscle fibers, with focally defective areas recapitulating the global alterations. Importantly, we found that pharmacological inhibition of phosphatidylinositol 3-kinase (PtdIns 3-kinase) activity rescues the Ca2+ release defects in isolated muscle fibers and increases the lifespan and mobility of XLMTM mice, providing proof of concept for the use of PtdIns 3-kinase inhibitors in myotubular myopathy and suggesting that unbalanced PtdIns 3-kinase activity plays a critical role in the pathological process. PMID:27911767

  12. Highly efficient optical power transfer to whispering-gallery modes by use of a symmetrical dual-coupling configuration.

    PubMed

    Cai, M; Vahala, K

    2000-02-15

    We report that greater than 99.8% optical power transfer to whispering-gallery modes was achieved in fused-silica microspheres by use of a dual-tapered-fiber coupling method. The intrinsic cavity loss and the taper-to-sphere coupling coefficient are inferred from the experimental data. It is shown that the low intrinsic cavity loss and the symmetrical dual-coupling structure are crucial for obtaining the high coupling efficiency.

  13. SERS Taper-Fiber Nanoprobe Modified by Gold Nanoparticles Wrapped with Ultrathin Alumina Film by Atomic Layer Deposition

    PubMed Central

    Xu, Wenjie; Chen, Zhenyi; Chen, Na; Zhang, Heng; Liu, Shupeng; Hu, Xinmao; Wen, Jianxiang; Wang, Tingyun

    2017-01-01

    A taper-fiber SERS nanoprobe modified by gold nanoparticles (Au-NPs) with ultrathin alumina layers was fabricated and its ability to perform remote Raman detection was demonstrated. The taper-fiber nanoprobe (TFNP) with a nanoscale tip size under 80 nm was made by heated pulling combined with the chemical etching method. The Au-NPs were deposited on the TFNP surface with the electrostatic self-assembly technology, and then the TFNP was wrapped with ultrathin alumina layers by the atomic layer deposition (ALD) technique. The results told us that with the increasing thickness of the alumina film, the Raman signals decreased. With approximately 1 nm alumina film, the remote detection limit for R6G aqueous solution reached 10−6 mol/L. PMID:28245618

  14. Assessment of Retention and Resistance Form of Tooth Preparations for All Ceramic Restorations using Digital Imaging Technique.

    PubMed

    Muruppel, Alex M; Thomas, Joyce; Saratchandran, Sudeep; Nair, Dinesh; Gladstone, Sheeba; Rajeev, Milen M

    2018-02-01

    This in vitro study evaluated the resistance form of die preparations for all ceramic restorations and, thereby, explored the concept of effective taper and its correlation between the ideal in theory and actual in the clinical situation by analyzing the digital images of the die preparations. Scanned digital images of 114 die preparations for all ceramic restorations (n = 114) were collected from a dental laboratory. All the images were also analyzed digitally using Adobe Photoshop® software to analyze the degree of taper (angle of convergence) of each preparation and then applied the Zuckerman's circle, and the Lewis perpendicular methods were used to measure the resistance form. For the current study, the overall average degree of taper was found to be 20.9° (range, 2-80°), which is more than what is recommended by most previous studies and also sharply greater than the textbook ideal of 3 to 6°. Mean degree of taper for maxillary was 17.56° (anterior-10.50°, posterior-23.7°), and for mandibular teeth, it was 25.22° (anterior-15°, posterior- 28.45°). Out of the 64 analyzed images of maxillary teeth, 61 presented resistance form, while 3 were without it. Out of the 50 mandibular teeth analyzed, 38 possessed resistance form, whereas 12 were without. All the anterior teeth showed resistance form irrespective of the arch. The degree of taper showed a significant relationship with resistance and retention form, which was inversely proportional to each other. The recommended "degree of taper" is not always the clinically achievable as advocated in textbooks, as it is modified by various factors in the actual clinical situation. The study provides scientific background regarding the relationship between the degree of taper with resistance and retention form, and the relationship was found to be inversely proportional to each other. The recommended "degree of taper" is not always the clinically achievable as advocated in textbooks, and it is modified by various modifying or limiting factors in the actual clinical situation.

  15. Tapering Practices of Croatian Open-Class Powerlifting Champions.

    PubMed

    Grgic, Jozo; Mikulic, Pavle

    2017-09-01

    Grgic, J and Mikulic, P. Tapering practices of Croatian open-class powerlifting champions. J Strength Cond Res 31(9): 2371-2378, 2017-The aim of this study was to explore tapering practices among 10 Croatian open-class powerlifting champions (mean ± SD: age 29.2 ± 3.2 years; Wilks coefficient 355.1 ± 54.8). The athletes were interviewed about their tapering practices using a semi-structured interview after which the audio content was transcribed. The athletes reported decreasing training volume during the taper by 50.5 ± 11.7% using a step type or an exponential type of taper with a fast decay. Training intensity was maintained or increased during the taper, and it reached its highest values 8 ± 3 days before the competition. Training frequency was reduced or maintained during the taper. The final week included a reduction in training frequency by 47.9 ± 17.5% with the last training session performed 3 ± 1 days before the competition. The participants typically stated that the main reasons for conducting the taper were maintaining strength and reducing the amount of fatigue. They also stated that (a) the taper was structured identically for the squat, bench press, and the deadlift; (b) the training during the taper was highly specific, the assistance exercises were removed, and the same equipment was used as during competition; (c) the source of information for tapering was their coach, and training fluctuated based on the coach's feedback; and (d) nutrition, foam rolling, static stretching, and massage were all given extra attention during the taper. These results may aid athletes and coaches in strength sports in terms of the optimization of tapering variables.

  16. Numerical analysis of double chirp effect in tapered and linearly chirped fiber Bragg gratings.

    PubMed

    Markowski, Konrad; Jedrzejewski, Kazimierz; Osuch, Tomasz

    2016-06-10

    In this paper, a theoretical analysis of recently developed tapered chirped fiber Bragg gratings (TCFBG) written in co-directional and counter-directional configurations is presented. In particular, the effects of the synthesis of chirps resulting from both a fused taper profile and a linearly chirped fringe pattern of the induced refractive index changes within the fiber core are extensively examined. For this purpose, a numerical model based on the transfer matrix method (TMM) and the coupled mode theory (CMT) was developed for such a grating. The impact of TCFBG parameters, such as grating length and steepness of the taper transition, as well as the effect of the fringe pattern chirp rate on the spectral properties of the resulting gratings, are presented. Results show that, by using the appropriate design process, TCFBGs with reduced or enhanced resulting chirp, and thus with widely tailored spectral responses, can be easily achieved. In turn, it reveals a great potential application of such structures. The presented numerical approach provides an excellent tool for TCFBG design.

  17. Investigation of AWG demultiplexer based SOI for CWDM application

    NASA Astrophysics Data System (ADS)

    Juhari, Nurjuliana; Susthitha Menon, P.; Shaari, Sahbudin; Annuar Ehsan, Abang

    2017-11-01

    9-channel Arrayed Waveguide Grating (AWG) demultiplexer for conventional and tapered structure were simulated using beam propagation method (BPM) with channel spacing of 20 nm. The AWG demultiplexer was design using high refractive index (n 3.47) material namely silicon-on-insulator (SOI) with rib waveguide structure. The characteristics of insertion loss, adjacent crosstalk and output spectrum response at central wavelength of 1.55 μm for both designs were compared and analyzed. The conventional AWG produced a minimum insertion loss of 6.64 dB whereas the tapered AWG design reduced the insertion loss by 2.66 dB. The lowest adjacent crosstalk value of -16.96 dB was obtained in the conventional AWG design and this was much smaller compared to the tapered AWG design where the lowest crosstalk value is -17.23 dB. Hence, a tapered AWG design significantly reduces the insertion loss but has a slightly higher adjacent crosstalk compared to the conventional AWG design. On the other hand, the output spectrum responses that are obtained from both designs were close to the Coarse Wavelength Division Multiplexing (CWDM) wavelength grid.

  18. Efficiency of the Self Adjusting File, WaveOne, Reciproc, ProTaper and hand files in root canal debridement

    PubMed Central

    Topcu, K. Meltem; Karatas, Ertugrul; Ozsu, Damla; Ersoy, Ibrahim

    2014-01-01

    Objectives: The aim of this study was to compare the canal debridement capabilities of three single file systems, ProTaper, and K-files in oval-shaped canals. Materials and Methods: Seventy-five extracted human mandibular central incisors with oval-shaped root canals were selected. A radiopaque contrast medium (Metapex; Meta Biomed Co. Ltd., Chungcheongbuk-do, Korea) was introduced into the canal systems and the self-adjusting file (SAF), WaveOne, Reciproc, ProTaper, and K-files were used for the instrumentation of the canals. The percentage of removed contrast medium was calculated using pre- and post-operative radiographs. Results: An overall comparison between the groups revealed that the hand file (HF) and SAF groups presented the lowest percentage of removed contrast medium, whereas the WaveOne group showed the highest percentage (P < 0.001). The ProTaper group removed more contrast medium than the SAF and HF groups (P < 0.05). Conclusions: None of the instruments was able to remove the contrast medium completely. WaveOne performed significantly better than other groups. PMID:25202211

  19. Method and apparatus for making superconductive magnet coils

    DOEpatents

    Borden, A.R.

    1983-11-07

    A curved, shell-type magnet coil, adapted to be used in a superconducting magnet, is wound by providing a mandrel having a tubular cylindrical mid-portion terminating at both ends in tapered end portions formed with longitudinal slots having flexible fingers therebetween. An elongated electrical conductor is wound around an elongated oval-shaped pole island engaged with the outside of the cylindrical mid-portion, to form a multiplicity of oval-shaped turns engaged with a 180-degree segment of the mandrel. The coil turns have longitudinal portions with curved portions therebetween, engaging the tapered end portions of the mandrel. Upon completion of the winding, tapered expansion members are fully inserted into the tapered end portions, to displace the flexible fingers outwardly into a cylindrical form and to displace the curved portions of the turns into a shape conforming to such cylindrical form while also exerting increased tension upon the turns to minimize draping of the turns and to enhance the mechanical integrity of the coil. A half cylinder clamp may then be employed to clamp the coil, whereupon the coil may be solidified by the use of an epoxy adhesive.

  20. Technique for writing of fiber Bragg gratings over or near preliminary formed macro-structure defects in silica optical fibers

    NASA Astrophysics Data System (ADS)

    Evtushenko, Alexander S.; Faskhutdinov, Lenar M.; Kafarova, Anastasia M.; Kazakov, Vadim S.; Kuznetzov, Artem A.; Minaeva, Alina Yu.; Sevruk, Nikita L.; Nureev, Ilnur I.; Vasilets, Alexander A.; Andreev, Vladimir A.; Morozov, Oleg G.; Burdin, Vladimir A.; Bourdine, Anton V.

    2017-04-01

    This work presents method for performing precision macro-structure defects "tapers" and "up-tapers" written in conventional silica telecommunication multimode optical fibers by commercially available field fusion splicer with modified software settings and following writing fiber Bragg gratings over or near them. We developed technique for macrodefect geometry parameters estimation via analysis of photo-image performed after defect writing and displayed on fusion splicer screen. Some research results of defect geometry dependence on fusion current and fusion time values re-set in splicer program are represented that provided ability to choose their "the best" combination. Also experimental statistical researches concerned with "taper" and "up-taper" diameter stability as well as their insertion loss values during their writing under fixed corrected splicer program parameters were performed. We developed technique for FBG writing over or near macro-structure defect. Some results of spectral response measurements produced for short-length samples of multimode optical fiber with fiber Bragg gratings written over and near macro-defects prepared by using proposed technique are presented.

  1. Method and apparatus for making superconductive magnet coils

    DOEpatents

    Borden, Albert R.

    1985-01-01

    A curved, shell-type magnet coil, adapted to be used in a superconducting magnet, is wound by providing a mandrel having a tubular cylindrical mid-portion terminating at both ends in tapered end portions formed with longitudinal slots having flexible fingers therebetween. An elongated electrical conductor is wound around an elongated oval-shaped pole island engaged with the outside of the cylindrical mid-portion, to form a multiplicity of oval-shaped turns engaged with a 180-degree segment of the mandrel. The coil turns have longitudinal portions with curved portions therebetween, engaging the tapered end portions of the mandrel. Upon completion of the winding, tapered expansion members are fully inserted into the tapered end portions, to displace the flexible fingers outwardly into a cylindrical form and to displace the curved portions of the turns into a shape conforming to such cylindrical form while also exerting increased tension upon the turns to minimize draping of the turns and to enhance the mechanical integrity of the coil. A half cylinder clamp may then be employed to clamp the coil, whereupon the coil may be solified by the use of an epoxy adhesive.

  2. Tapering Practices of Strongman Athletes.

    PubMed

    Winwood, Paul W; Dudson, Mike K; Wilson, Daniel; Mclaren-Harrison, Justice K H; Redjkins, Vladislav; Pritchard, Hayden J; Keogh, Justin W L

    2018-05-01

    Winwood, PW, Dudson, MK, Wilson, D, Mclaren-Harrison, JKH, Redjkins, V, Pritchard, HJ, and Keogh, JWL. Tapering practices of strongman athletes. J Strength Cond Res 32(5): 1181-1196, 2018-This study provides the first empirical evidence of how strongman athletes taper for strongman competitions. Strongman athletes (n = 454) (mean ± SD: 33.2 ± 8.0 years, 178.1 ± 10.6 cm, 108.6 ± 27.9 kg, 12.6 ± 8.9 years general resistance training, 5.3 ± 5.0 years strongman implement training) completed a self-reported 4-page internet survey on tapering practices. Analysis by sex (male and female), age (≤30 and >30 years), body mass (≤105 and >105 kg), and competitive standard (local/regional amateur, national amateur and professional) was conducted. Eighty-seven percent (n = 396) of strongman athletes reported that they used a taper. Athletes stated that their typical taper length was 8.6 ± 5.0 days, with the step taper the most commonly performed taper (52%). Training volume decreased during the taper by 45.5 ± 12.9%, and all training ceased 3.9 ± 1.8 days out from competition. Typically, athletes reported that training frequency and training duration stayed the same or decreased and training intensity decreased to around 50% in the last week. Athletes generally stated that tapering was performed to achieve recovery, rest, and peak performance; the deadlift, yoke walk, and stone lifts/work took longer to recover from than other lifts; assistance exercises were reduced or removed in the taper; massage, foam rolling, nutritional changes, and static stretching were strategies used in the taper; and, poor tapering occurred when athletes trained too heavy/hard or had too short a taper. These data will assist strongman athletes and coaches in the optimization of tapering variables leading to more peak performances. Future research could investigate the priming and preactivation strategies strongman athletes use on competition day.

  3. Numerical modelling on stimulated Brillouin scattering characterization for Graphene-clad tapered silica fiber

    NASA Astrophysics Data System (ADS)

    Lee, Hui Jing; Abdullah, Fairuz; Ismail, Aiman

    2017-11-01

    This paper presents finite numerical modelling on the cross-sectional region of tapered single mode fiber and graphene-clad tapered fiber. Surface acoustic wave propagation across the tapered surface region on tapered single mode fiber has a high threshold power at 61.87 W which is challenging to overcome by the incident pump wave. Surface acoustic wave propagation of fiber surface however made tapered wave plausible in the optical sensor application. This research introduces graphene as the cladding layer on tapered fiber, acoustic confinement occurs due to the graphene cladding which lowers the threshold power from 61.87 W to 2.17 W.

  4. Electrochemical impedance spectroscopy investigation on the clinical lifetime of ProTaper rotary file system.

    PubMed

    Penta, Virgil; Pirvu, Cristian; Demetrescu, Ioana

    2014-01-01

    The main objective of the current paper is to show that electrochemical impedance spectroscopy (EIS) could be a method for evaluating and predicting of ProTaper rotary file system clinical lifespan. This particular aspect of everyday use of the endodontic files is of great importance in each dental practice and has profound clinical implications. The method used for quantification resides in the electrochemical impedance spectroscopy theory and has in its main focus the characteristics of the surface titanium oxide layer. This electrochemical technique has been adapted successfully to identify the quality of the Ni-Ti files oxide layer. The modification of this protective layer induces changes in corrosion behavior of the alloy modifying the impedance value of the file. In order to assess the method, 14 ProTaper sets utilized on different patients in a dental clinic have been submitted for testing using EIS. The information obtained in regard to the surface oxide layer has offered an indication of use and proves that the said layer evolves with each clinical application. The novelty of this research is related to an electrochemical technique successfully adapted for Ni-Ti file investigation and correlation with surface and clinical aspects.

  5. A One-year Follow-up Study of a Tapered Hydrophilic Implant Design Using Various Placement Protocols in the Maxilla

    PubMed Central

    Zwaan, Jakob; Vanden Bogaerde, Leonardo; Sahlin, Herman; Sennerby, Lars

    2016-01-01

    Purpose: To study the clinical/radiographic outcomes and stability of a tapered implant design with a hydrophilic surface when placed in the maxilla using various protocols and followed for one year. Methods: Ninety-seven consecutive patients treated as part of daily routine in two clinics with 163 tapered implants in healed sites, in extraction sockets and together with bone augmentation procedures in the maxilla were evaluated after one year in function. Individual healing periods varying from 0 to 6 months had been used. Insertion torque (IT) and resonance frequency analysis (RFA) measurements were made at baseline. Follow-up RFA registrations were made after 6 and 12 months of loading. The marginal bone levels were measured in intraoral radiographs from baseline and after 12 months. A reference group consisting of 163 consecutive straight maxillary implants was used for the comparison of baseline IT and RFA measurements. Results: Five implants failed before loading, giving an implant survival rate of 96.9% and a prosthesis survival rate of 99.4% after one year. The mean marginal bone loss after one year was 0.5 mm (SD 0.4). The mean IT was statistically significantly higher for tapered than for straight reference implants (41.3 ± 12.0 Ncm vs 33.6 ± 12.5 Ncm, p < 0.001). The tapered implants showed a statistically insignificantly higher mean ISQ value than the straight references implants (73.7 ± 6.4 ISQ vs 72.2 ± 8.0 ISQ, p=0.119). There was no correlation between IT and marginal bone loss. There was a correlation between IT and RFA measurements (p < 0.001). Conclusion: The tapered implant showed a high survival rate and minimal marginal bone loss after one year in function when using various protocols for placement. The tapered implant showed significantly higher insertion torque values than straight reference implants. PMID:28077972

  6. Fabrication of an Optical Fiber Micro-Sphere with a Diameter of Several Tens of Micrometers.

    PubMed

    Yu, Huijuan; Huang, Qiangxian; Zhao, Jian

    2014-06-25

    A new method to fabricate an integrated optical fiber micro-sphere with a diameter within 100 µm, based on the optical fiber tapering technique and the Taguchi method is proposed. Using a 125 µm diameter single-mode (SM) optical fiber, an optical fiber taper with a cone angle is formed with the tapering technique, and the fabrication optimization of a micro-sphere with a diameter of less than 100 µm is achieved using the Taguchi method. The optimum combination of process factors levels is obtained, and the signal-to-noise ratio (SNR) of three quality evaluation parameters and the significance of each process factors influencing them are selected as the two standards. Using the minimum zone method (MZM) to evaluate the quality of the fabricated optical fiber micro-sphere, a three-dimensional (3D) numerical fitting image of its surface profile and the true sphericity are subsequently realized. From the results, an optical fiber micro-sphere with a two-dimensional (2D) diameter less than 80 µm, 2D roundness error less than 0.70 µm, 2D offset distance between the micro-sphere center and the fiber stylus central line less than 0.65 µm, and true sphericity of about 0.5 µm, is fabricated.

  7. Bending stiffness, torsional stability, and insertion force of cementless femoral stems.

    PubMed

    Incavo, S J; Johnson, C C; Churchill, D L; Beynnon, B D

    2001-04-01

    In cementless total hip arthroplasty, increased femoral stem flexibility and decreased fracture propensity are desirable characteristics. The slotting and tapering of the stem have been introduced to achieve this. These features should not, however, be allowed to interfere with the ability of the distal stem to provide initial mechanical stability, especially under rotation. This study was done to investigate the ability of slotted and tapered stem designs to reduce stiffness and insertion force while still maintaining adequate torsional strength. The torsional strength, maximum insertion force, and insertional work of straight, slotted, and taper stems were measured by inserting each type into rigid polyurethane foam and torque testing to failure. Bending stiffness of each stem design was calculated using numerical methods. When compared to a straight stem, a unislot stem has similar torsional strength, maximum insertional force, and work of insertion. The bending stiffness is decreased by 19% to 82% depending on the bending direction. A trislot design decreased torque strength by 29%, maximal insertion force by 36%, and work by 11%. Bending stiffness was decreased by 74% and was not dependent on bending direction. A 0.5-mm taper decreased torque strength by 11% and insertional work by 14%. No difference was seen in maximum insertional force. We conclude that the design features studied (slots and taper) are effective in decreasing stem stiffness and reducing fracture propensity.

  8. Supercontinuum generation covering the entire 0.4-5 µm transmission window in a tapered ultra-high numerical aperture all-solid fluorotellurite fiber

    NASA Astrophysics Data System (ADS)

    Jia, Z. X.; Yao, C. F.; Jia, S. J.; Wang, F.; Wang, S. B.; Zhao, Z. P.; Liao, M. S.; Qin, G. S.; Hu, L. L.; Ohishi, Y.; Qin, W. P.

    2018-02-01

    Enormous efforts have been made to realize supercontinuum (SC) generation covering the entire transmission window of fiber materials for their wide applications in many fields. Here we demonstrate ultra-broadband SC generation from 400 to 5140 nm in a tapered ultra-high numerical aperture (NA) all-solid fluorotellurite fiber pumped by a 1560 nm mode-locked fiber laser. The fluorotellurite fibers are fabricated using a rod-in-tube method. The core and cladding materials are TeO2-BaF2-Y2O3- and TeO2-modified fluoroaluminate glasses, respectively, which have large refractive index contrast and similar thermal expansion coefficients and softening temperatures. The NA at 3200 nm of the fluorotellurite fiber is about 1.11. Furthermore, tapered fluorotellurite fibers are prepared using an elongation machine. SC generation covering the entire 0.4-5 µm transmission window is achieved in a tapered fluorotellurite fiber for a pumping peak power of ~10.5 kW through synergetic control of dispersion, nonlinearity, confinement loss and other unexpected effects (e.g. the attachment of dust or water to the surface of the fiber core) of the fiber. Our results show that tapered ultra-high NA all-solid soft glass fibers have a potential for generating SC light covering their entire transmission window.

  9. Tunable self-seeded multi-wavelength Brillouin-erbium fiber laser based on few-mode fiber filter

    NASA Astrophysics Data System (ADS)

    Zou, Hui; Ma, Lei; Xiong, Hui; Zhang, Yun-shan; Liu, Chun-xiao

    2017-11-01

    A tunable self-seeded multi-wavelength Brillouin-erbium fiber laser (BEFL) is proposed and demonstrated based on a few-mode fiber filter (FMFF) with varying temperature. The FMFF configuration is a section of uncoated few-mode fiber (FMF) sandwiched between two up-tapers. As the temperature varies from 25 °C to 125 °C, the transmission spectrum of FMFF moves towards the longer wavelength. The self-excited Brillouin pump is internally achieved by cascaded stimulated Brillouin scattering (SBS) in the single mode fiber (SMF). Then employing the FMFF temperature variation characteristics in the ring cavity fiber laser, the multi-wavelength of the output laser can be tuned, and the tunable range is about 8.0 nm. The generation of up to 15 Brillouin Stokes wavelengths with 16 dB optical signal- to-noise ratio ( OSNR) is realized.

  10. Switchable multi-wavelength fiber laser based on modal interference

    NASA Astrophysics Data System (ADS)

    Ma, Lin; Jiang, Sun; Qi, Yan-Hui; Kang, Ze-Xin; Jian, Shui-Sheng

    2015-08-01

    A comb fiber filter based on modal interference is proposed and demonstrated in this paper. Here two cascaded up-tapers are used to excite the cladding mode, and a core-offset jointing point is used to act as an interference component. Experimental results show that this kind of structure possesses a comb filter property in a range of the C-band. The measured extinction ratio is better than 12 dB with an insertion loss of about 11 dB. A switchable multi-wavelength erbium-doped fiber laser based on this novel comb filter is demonstrated. By adjusting the polarization controller, the output laser can be switched among single-, dual-, and three-wavelengths with a side mode suppression ratio of better than 45 dB.

  11. New coplanar waveguide feed network for 2 x 2 linearly tapered slot antenna subarray

    NASA Technical Reports Server (NTRS)

    Simons, Rainee N.; Perl, Thomas D.; Lee, Richard Q.

    1992-01-01

    A novel feed method is presently demonstrated for a 2 x 2 linearly tapered slot antenna (LTSA) on the basis of a coplanar-waveguide (CPW)-to-slotline transition and a coax-to-CPW in-phase, four-way power divider. The LTSA subarray exhibits excellent radiation patterns and return-loss characteristics at 18 GHz, and has symmetric beamwidth; its compactness renders it applicable as either a feed for a reflector antenna or as a building-block for large arrays.

  12. Gaussian Filtering with Tapered Oil-Filled Photonic Bandgap Fibers

    NASA Astrophysics Data System (ADS)

    Brunetti, A. C.; Scolari, L.; Weirich, J.; Eskildsen, L.; Bellanca, G.; Bassi, P.; Bjarklev, A.

    2008-10-01

    A tunable Gaussian filter based on a tapered oil-filled photonic crystal fiber is demonstrated. The filter is centered at λ = 1364 nm with a bandwidth (FWHM) of 237nm. Tunability is achieved by changing the temperature of the filter. A shift of 210nm of the central wavelength has been observed by increasing the temperature from 25 °C to 100 °C. The measurements are compared to a simulated spectrum obtained by means of a vectorial Beam Propagation Method model.

  13. A temperature control design for a tapered element oscillating microbalance sensing surface

    NASA Technical Reports Server (NTRS)

    1982-01-01

    A design study is presented which shows that a tapered element oscillating microbalance can be adapted for temperature control under space application by mating with multistage thermoelectric coolers in such a way that an integral structure evolves. The control of the temperature of the sensing surface can be achieved in a number of ways. An indirect method which uses a measurement of the absorbed power is recommended. The design goals can be met if a relaxation of the power requirement can be considered.

  14. 2D constant-loss taper for mode conversion

    NASA Astrophysics Data System (ADS)

    Horth, Alexandre; Kashyap, Raman; Quitoriano, Nathaniel J.

    2015-03-01

    Proposed in this manuscript is a novel taper geometry, the constant-loss taper (CLT). This geometry is derived with 1D slabs of silicon embedded in silicon dioxide using coupled-mode theory (CMT). The efficiency of the CLT is compared to both linear and parabolic tapers using CMT and 2D finite-difference time-domain simulations. It is shown that over a short 2D, 4.45 μm long taper the CLT's mode conversion efficiency is ~90% which is 10% and 18% more efficient than a 2D parabolic or linear taper, respectively.

  15. Computed Tomographic Evaluation of K3 Rotary and Stainless Steel K File Instrumentation in Primary Teeth

    PubMed Central

    Kavitha, Swaminathan; Thomas, Eapen; Anadhan, Vasanthakumari; Vijayakumar, Rajendran

    2016-01-01

    Introduction The intention of root canal preparation is to reduce infected content and create a root canal shape allowing for a well condensed root filling. Therefore, it is not necessary to remove excessive dentine for successful root canal preparation and concern must be taken not to over instrument as perforations can occur in the thin dentinal walls of primary molars. Aim This study was done to evaluate the time preparation, the risk of lateral perforation and dentine removal of the stainless steel K file and K3 rotary instrumentation in primary teeth. Materials and Methods Seventy-five primary molars were selected and divided into three groups. Using spiral computed tomography the teeth were scanned before instrumentation. Teeth were prepared using a stainless steel K file for manual technique. All the canals were prepared up to file size 35. In K3 rotary files (.02 taper) instrumentation was done up to 35 size file. In K3 rotary files (.04 taper) the instrumentation was done up to 25 size file and simultaneously the instrumentation time was recorded. The instrumented teeth were once again scanned and the images were compared with the images of the uninstrumented canals. Statistical Analysis Data was statistically analysed using Kruskal Wallis One-way ANOVA, Mann-Whitney U-Test and Pearson’s Chi-square Test. Results K3 rotary files (.02 taper) removed a significantly less amount of dentine, required less instrumentation time than a stainless steel K file. Conclusion K3 files (.02 taper) generated less dentine removal than the stainless steel K file and K3 files (.04 taper). K3 rotary files (.02 taper) were more effective for root canal instrumentation in primary teeth. PMID:26894166

  16. Comparative evaluation of canal transportation, centering ability, and remaining dentin thickness between WaveOne and ProTaper rotary by using cone beam computed tomography: An in vitro study

    PubMed Central

    Jain, Aditi; Asrani, Hemant; Singhal, Abhinav Chand; Bhatia, Taranjeet Kaur; Sharma, Vaibhav; Jaiswal, Pragya

    2016-01-01

    Aims: To compare the canal transportation, centering ability, and remaining dentin thickness of WaveOne and ProTaper systems using cone beam computed tomography. Subjects and Methods: Forty extracted human single-rooted premolars were used in the present study. Preinstrumentation scanning of all teeth was taken; canal curvatures were calculated, and the samples were randomly divided into two groups, with twenty samples in each group; one group was instrumented with WaveOne system and the other group with ProTaper rotary system. Postinstrumentation scans were performed, and the two scans were compared to determine canal transportation, centering ability, and remaining dentin thickness at 3 mm, 6 mm, and 9 mm from the root apex. Statistical Analysis Used: Student's unpaired t-test. Results: Using Student's unpaired t-test, results were as follows: for canal transportation, Group 1 showed significant difference at 3 mm and 6 mm and insignificant difference at 9 mm while Group 2 showed insignificant difference in all the three regions. For centering ability and remaining dentin thickness, Group 1 showed insignificant difference at 3 mm and 9 mm while significant difference at 6 mm was obtained. When comparison of remaining dentin thickness was done at three levels using two groups WaveOne and ProTaper, there was no significant difference between two groups. Conclusions: (1) WaveOne single reciprocation file system respected better canal anatomy better than ProTaper. (2) Individually, centering ability of WaveOne was better at 3 mm, 6 mm, and 9 mm levels. (3) However, ProTaper individually was better centered at 3 mm (apical third) and 9 mm (coronal 3rd) levels than 6 mm level (middle third). PMID:27656063

  17. Apical root canal transportation of different pathfinding systems and their effects on shaping ability of ProTaper Next

    PubMed Central

    Türker, Sevinç-Aktemur

    2015-01-01

    Background This study aimed to compare glide path preparation of different pathfinding systems and their effects on the apical transportation of ProTaper Next (Dentsply Maillefer, Ballaigues, Switzerland) in mesial root canals of extracted human mandibular molars, using digital subtraction radiography. Material and Methods The mesial canals of 40 mandibular first molars (with curvature angles between 25° and 35°) were selected for this study. The specimens were divided randomly into 4 groups with 10 canals each. Glide paths were created in group 1 with #10, #15 and #20 K-type (Dentsply Maillefer, Ballaigues, Switzerland) stainless steel manual files; in group 2 with Path-File (Dentsply Maillefer) #1, #2, and #3 and in group 3 with #16 ProGlider (Dentsply Maillefer) rotary instruments; in group 4 no glide paths were created. All canals were instrumented up to ProTaper Next X2 to the working length. A double digital radiograph technique was used, pre and post-instrumentation, to assess whether apical transportation and/or aberration in root canal morphology occurred. Instrument failures were also recorded. The data were analyzed statistically using ANOVA and Tukey tests (p<0.05). Results No significant differences were found among groups regarding apical transportation (p>0.05). Two ProTaper Next instruments failed in-group 4. Conclusions Within the parameters of this study, there was no difference between the performance of path-finding files and ProTaper Next system maintained root canal curvature well and was safe to use either with path-finding files or alone. Key words:Glide path, PathFile, ProGlider, ProTaper Next, transportation. PMID:26330936

  18. The effects of autoclave sterilization on the cyclic fatigue resistance of ProTaper Universal, ProTaper Next, and ProTaper Gold nickel-titanium instruments

    PubMed Central

    2017-01-01

    Objectives It was aimed to compare the cyclic fatigue resistances of ProTaper Universal (PTU), ProTaper Next (PTN), and ProTaper Gold (PTG) and the effects of sterilization by autoclave on the cyclic fatigue life of nickel-titanium (NiTi) instruments. Materials and Methods Eighty PTU, 80 PTN, and 80 PTG were included to the present study. Files were tested in a simulated canal. Each brand of the NiTi files were divided into 4 subgroups: group 1, as received condition; group 2, pre-sterilized instruments exposed to 10 times sterilization by autoclave; group 3, instruments tested were sterilized after being exposed to 25%, 50%, and 75% of the mean cycles to failure, then cycled fatigue test was performed; group 4, instruments exposed to the same experiment with group 3 without sterilization. The number of cycles to failure (NCF) was calculated. The data was statistically analyzed by using one-way analysis of variance and post hoc Tukey tests. Results PTG showed significantly higher NCF than PTU and PTN in group 1 (p < 0.05). Sterilization significantly increased the NCF of PTN and PTG (p < 0.05) in group 2. PTN in group 3 had significantly higher cyclic fatigue resistance than PTN group 4 (p < 0.05). Also, significantly higher NCF was observed for PTG in group 2 than in groups 3 and 4 (p < 0.05). Conclusions PTG instrument made of new gold alloy was more resistant to fatigue failure than PTN and PTU. Autoclaving increased the cyclic fatigue resistances of PTN and PTG. PMID:29142878

  19. Canal Transportation and Centering Ability of ProTaper and SafeSider in Preparation of Curved Root Canals: A CBCT Evaluation

    PubMed Central

    Delgoshayi, Negar; Abbasi, Mansoure; Bakhtiar, Hengameh; Sakhdari, Shirin; Ghannad, Setareh; Ellini, Mohammad Reza

    2018-01-01

    Introduction: Maintaining the original central canal path is an important parameter in efficient root canal preparation. Instruments causing minimal changes in original canal path are preferred for this purpose. This study sought to compare canal transportation and centering ability of ProTaper and SafeSider instruments in curved mesiobuccal root canals of mandibular first molars using cone beam computed tomography (CBCT). Methods and Materials : In this experimental study, 30 mesiobuccal root canals of extracted human mandibular first molars with 20° to 40° curvature were randomly divided into two groups (n=15). After mounting in putty, preoperative CBCT scans were obtained of teeth. Root canals in group A were shaped using S1, S2, F1 and F2 of ProTaper system. Root canals in group B were instrumented to size 25 using SafeSider system according to the manufacturers’ instructions. Postoperative CBCT scans were then obtained. The distance between the external root surface and internal canal wall was measured at the mesial and distal at 1, 3 and 7 mm from the apex. The values measured on primary and secondary CBCT scans were compared to assess possible changes in original central canal path and canal transportation. Data were compared using the t-test and repeated measure ANOVA. Results: ProTaper and SafeSider were significantly different in terms of canal transportation and centering ability, and ProTaper was significantly superior to SafeSider in this respect (P<0.001). Conclusion: ProTaper (in contrast to SafeSider) is well capable of maintaining the original central canal path with the least amount of transportation. PMID:29707022

  20. Evaluation of removal forces of implant-supported zirconia copings depending on abutment geometry, luting agent and cleaning method during re-cementation

    PubMed Central

    Rödiger, Matthias; Rinke, Sven; Ehret-Kleinau, Fenja; Pohlmeyer, Franziska; Lange, Katharina; Bürgers, Ralf

    2014-01-01

    PURPOSE To evaluate the effects of different abutment geometries in combination with varying luting agents and the effectiveness of different cleaning methods (prior to re-cementation) regarding the retentiveness of zirconia copings on implants. MATERIALS AND METHODS Implants were embedded in resin blocks. Three groups of titanium abutments (pre-fabricated, height: 7.5 mm, taper: 5.7°; customized-long, height: 6.79 mm, taper: 4.8°; customized-short, height: 4.31 mm, taper: 4.8°) were used for luting of CAD/CAM-fabricated zirconia copings with a semi-permanent (Telio CS) and a provisional cement (TempBond NE). Retention forces were evaluated using a universal testing machine. Furthermore, the influence of cleaning methods (manually, manually in combination with ultrasonic bath or sandblasting) prior to re-cementation with a provisional cement (TempBond NE) was investigated with the pre-fabricated titanium abutments (height: 7.5 mm, taper: 5.7°) and SEM-analysis of inner surfaces of the copings was performed. Significant differences were determined via two-way ANOVA. RESULTS Significant interactions between abutment geometry and luting agent were observed. TempBond NE showed the highest level of retentiveness on customized-long abutments, but was negatively affected by other abutment geometries. In contrast, luting with Telio CS demonstrated consistent results irrespective of the varying abutment geometries. Manual cleaning in combination with an ultrasonic bath was the only cleaning method tested prior to re-cementation that revealed retentiveness levels not inferior to primary cementation. CONCLUSION No superiority for one of the two cements could be demonstrated because their influences on retentive strength are also depending on abutment geometry. Only manual cleaning in combination with an ultrasonic bath offers retentiveness levels after re-cementation comparable to those of primary luting. PMID:25006388

  1. Evaluation of retention and fracture resistance of different fiber reinforced posts: An in vitro study.

    PubMed

    Pruthi, Varun; Talwar, Sangeeta; Nawal, Ruchika Roongta; Pruthi, Preeti Jain; Choudhary, Sarika; Yadav, Seema

    2018-01-01

    The aim of this study was to evaluate retention & fracture resistance of different fibre posts. 90 extracted human permanent maxillary central incisors were used in this study. For retention evaluation, after obturation, post space preparation was done in all root canals and posts were cemented under three groups. Later, the posts were grasped & pulled out from the roots with the help of a three-jaw chuck at a cross-head speed of 5mm/min. Force required to dislodge each post was recorded in Newtons. To evaluate the fracture behavior of posts, artificial root canals were drilled into aluminium blocks and posts were cemented. Load required to fracture each post was recorded in Newtons. The results of the present study show the mean retention values for Fibrekleer Parallel post were significantly greater than those for Synca Double tapered post & Bioloren Tapered post. The mean retention values of the Double tapered post & the tapered post were not statistically different. The Synca Double tapered post had the highest mean load to fracture, and this value was significantly higher than those of FibreKleer Parallel & Bioloren Tapered post. The mean fracture resistance values of Parallel & tapered post were not statistically different. This study showed parallel posts to have better retention than tapered and double tapered posts. Regarding the fracture resistance, double tapered posts were found to be better than parallel and tapered posts.

  2. Comparison of Measured and Calculated Stresses in Built-up Beams

    NASA Technical Reports Server (NTRS)

    Levin, L Ross; Nelson, David H

    1946-01-01

    Web stresses and flange stresses were measured in three built-up beams: one of constant depth with flanges of constant cross-section, one linearly tapered in depth with flanges of constant cross section, and one linearly tapered in depth with tapered flanges. The measured stresses were compared with the calculated stresses obtained by the methods outlined in order to determine the degree of accuracy that may be expected from the stress analysis formulas. These comparisons indicated that the average measured stresses for all points in the central section of the beams did not exceed the average calculated stresses by more than 5 percent. It also indicated that the difference between average measured flange stresses and average calculated flange stresses on the net area and a fully effective web did not exceed 6.1 percent.

  3. High efficiency tapered free-electron lasers with a prebunched electron beam

    DOE PAGES

    Emma, C.; Sudar, N.; Musumeci, P.; ...

    2017-11-17

    In this study we analyze the high gain, high efficiency tapered free-electron laser amplifier with a prebunched electron beam. Simple scaling laws are derived for the peak output power and extraction efficiency and verified using 1D simulations. These studies provide useful analytical expressions which highlight the benefits resulting from fine control of the initial conditions of the system, namely the initial electron beam bunching and input seed radiation. When time-dependent effects are included, the sideband instability is known to limit the radiation amplification due to particle detrapping. We discuss two different approaches to mitigate the sideband growth via 1-D timemore » dependent simulations. We find that a more aggressive taper enabled by strong prebunching and a modulation of the resonance condition are both effective methods for suppressing the sideband instability growth rate.« less

  4. Performance study of winglets on tapered wing with curved trailing edge

    NASA Astrophysics Data System (ADS)

    Ara, Ismat; Ali, Mohammad; Islam, Md. Quamrul; Haque, M. Nazmul

    2017-06-01

    Induced drag is the result of wingtip vortex produced from generating lift by finite wing. It is one of the main drags that an aircraft wing encounters during flight. It hampers aircraft performance by increasing fuel consumption and reducing endurance, range and speed. Winglets are used to reduce the induced drag. They weakens wingtip vortex and thus reduces induced drag. This paper represents the experimental investigation to reduce induced drag using winglet at the wingtip. A model of tapered wing with curved trailing edge (without winglet) as well as two similar wings with blended winglet and double blended winglet are prepared using NACA 4412 aerofoil in equal span and surface area. All the models are tested in a closed circuit subsonic wind tunnel at air speed of 108 km/h (0.09 Mach). Reynolds number of the flow is 2.28 × 105 on the basis of average chord length of the wings. The point surface static pressures at different angles of attack from -4° to 24° are measured for each of the wing and winglet combinations through different pressure tapings by using a multi-tube water manometer. From the static pressure distribution, lift coefficient, drag coefficient and lift to drag ratio of all models are calculated. From the analysis of calculated values, it is found that both winglets are able to minimize induced drag; however, the tapered curved trailing edge span with blended winglet provides better aerodynamic performance.

  5. Effect of waist diameter and twist on tapered asymmetrical dual-core fiber MZI filter.

    PubMed

    Liu, Yan; Li, Yang; Yan, Xiaojun; Li, Weidong

    2015-10-01

    A compact in-fiber Mach-Zehnder interferometer (MZI) filter fabricated from custom-designed asymmetrical dual-core fiber is numerically analyzed in detail and experimentally verified. The asymmetrical dual-core fiber has core diameters and a core pitch of 6.9, 6, and 19.9 μm, respectively. The fiber tapering technique is introduced to fuse the originally uncoupled cores into strong coupling tapered regions. The length and diameter of the waist region have a close impact on the splitting ratio, which further affects the spectral properties of the MZI filter. The field evolution with varied waist parameters is characterized by the finite element method and beam propagation method. Repeatable comb filters with ∼15  dB extinction ratio are successfully achieved under the guidance of simulated optimum conditions. The twist-induced circular birefringence gives rise to a retardance that causes the spectral shifts of the MZI filter. The theoretical and experimental results confirm that the relative wavelength shift is proportional to the retardance, which follows a sinc function in the limit of a large twist rate.

  6. Tapered fiber nanoprobes: plasmonic nanopillars on tapered optical fiber tips for large EM enhancement.

    PubMed

    Savaliya, Priten; Dhawan, Anuj

    2016-10-01

    Employing finite difference time domain simulations, we demonstrate that electromagnetic field enhancement is substantially greater for tapered optical fibers with plasmonic nanostructures present on their tips as compared with non-tapered optical fibers having those plasmonic nanostructures, or with tapered optical fibers without the plasmonic nanostructures. We also carried out fabrication of plasmonic nanostructures on optical fiber tips.

  7. Integration of remote blood glucose meter upload technology into a clinical pharmacist medication therapy management service.

    PubMed

    Schenk, Robert J; Schenk, Jenna

    2011-01-01

    A pharmacist-delivered, outpatient-focused medication therapy management (MTM) program is using a remote blood glucose (BG) meter upload device to provide better care and to improve outcomes for its patients with diabetes. Sharing uploaded BG meter data, presented in easily comprehensible graphs and charts, enables patients, caregivers, and the medical team to better understand how the patients' diabetes care is progressing. Pharmacists are becoming increasingly more active in helping to manage patients' complex medication regimens in an effort to help detect and avoid medication-related problems. Working together with patients and their physicians as part of an interdisciplinary health care team, pharmacists are helping to improve medication outcomes. This article focuses on two case studies highlighting the Diabetes Monitoring Program, one component of the Meridian Pharmacology Institute MTM service, and discusses the clinical application of a unique BG meter upload device. © 2010 Diabetes Technology Society.

  8. Geologic Mapping of MTM -30247, -35247 and -40247 Quadrangles, Reull Vallis Region of Mars

    NASA Technical Reports Server (NTRS)

    Mest, S. C.; Crown, D. A.

    2008-01-01

    Geologic mapping and stratigraphic analyses of MTM -30247, -35247, and -40247 quadrangles are being used to characterize the Reull Vallis (RV) system and to determine the history of the eastern Hellas region of Mars. Studies of RV examine the roles and timing of volatile-driven erosional and depositional processes and provide constraints on potential associated climatic changes. This study complements earlier investigations of the eastern Hellas region, including regional analyses [1-6], mapping studies of circum-Hellas canyons [7-10], and volcanic studies of Hadriaca and Tyrrhena Paterae [11-13]. Key scientific objectives for these quadrangles include 1) characterization of RV in its "fluvial zone," 2) analysis of channels in the surrounding plains and potential connections to and interactions with RV, 3) examination of young (?), presumably sedimentary plains along RV that embay the surrounding highlands, and 4) determination of the nature of the connection between segments 1 and 2 of RV.

  9. [Shaping ability of two nickel-titanium rotary systems in simulated S-shaped canals].

    PubMed

    Luo, Hong-xia; Huang, Ding-ming; Zhang, Fu-hua; Tan, Hong; Zhou, Xue-dong

    2008-01-01

    To evaluate the shaping ability of two nickel-titanium rotary systems (ProTaper and Hero642) in simulated S-shaped canals. Thirty simulated S-shaped canals were randomly divided into three groups and prepared by ProTaper, Hero642, ProTaper combined with Hero642 respectively. All the canals were scanned before and after instrumentation, and the amount of material removed in the inner and outer wall and the canal width after instrumentation were measured with a computer image analysis program. There was significant difference in the amount of material removed at the inner side of apical curvature and outer side of apex between ProTaper combined with Hero642 and ProTaper files (P < 0.05) at the same tip size. The inner and outer wall of the canals were evenly prepared by ProTaper combined with Hero642, and the taper of canals were better than those prepared by Hero642. ProTaper combined with Hero 642 had better shaping ability to maintain the original shape and could create good taper canals in the simulated S-shaped canal model.

  10. Instrument separation analysis of multi-used ProTaper Universal rotary system during root canal therapy.

    PubMed

    Wu, Jintao; Lei, Gang; Yan, Ming; Yu, Yan; Yu, Jinhua; Zhang, Guangdong

    2011-06-01

    The purpose of this study was to identify the influential factors responsible for clinical instrument separation of reused ProTaper Universal rotary instruments (Dentsply Maillefer, Ballaigues, Switzerland). Six thousand one hundred fifty-four root canals in 2,654 teeth were prepared using ProTaper Universal files in endodontic clinics. Separation incidence was determined based on the number of treated teeth or canals. Data were collected including the size of fractured instrument, the length and location of a broken segment within the root canal, and the curvature of canal. The chi-square test and independent samples t test were used to determine the statistical significance. The overall instrument separation incidences were 2.6% according to the number of teeth and 1.1% according to the canal number, respectively. Separation incidences according to the number of teeth or canals were significantly higher (P < .05) in molars than those in premolars or anterior teeth. Because of its largest diameter, F3 file presented the highest separation incidence according to the number of teeth (1.0%) or canals (0.4%); 47.5% instrument separation of mandibular molars and 61.5% instrument separation of maxillary molars happened in the mesiobuccal canals. Moreover, 91.4% fragments were located in the apical third of root canals, and 54.2% instrument separation occurred in severely curved canals. There was a significant difference (P < .05) in the mean fracture length between shaping (2.42 ± 0.73 mm) and finishing files (3.32 ± 0.73 mm). Separation incidence according to the canal number is more reliable than that according to the number of teeth because of the variable canal number in different teeth. The tooth type, rotary file size, canal location, and anatomy were correlated with the instrument separation of reused ProTaper Universal files. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  11. Past, present and perspectives of Manipur traditional medicine: A major health care system available for rural population in the North-East India.

    PubMed

    Deb, Lokesh; Laishram, Surbala; Khumukcham, Nongalleima; Ningthoukhongjam, Dhaneshwor; Nameirakpam, Surjit Singh; Dey, Amitabha; Moirangthem, Dinesh Singh; Talukdar, Narayan Chandra; Ningthoukhongjam, Tombi Raj

    2015-07-01

    Traditional health care practices are still being followed extensively in Manipur, North-East India. This is the major or the only medical facility available in some rural areas of Manipur. Cross cultural ethno-pharmacological survey was conducted to document traditional health care practices by Maiba-Maibi (male-female traditional health care practitioners of Manipur). All together 59 traditional practitioners belonging to 12 ethnic communities in nine districts of the Manipur state were interviewed. A predesigned questionnaire was used for interviews, which included queries for type of ailments treating, symptoms, bioresources used, method of preparation, dosage forms, formulation, unit doses. The entire interviews were done in the residence of respective Maiba-Maibi, their patient handing and preparation of medicinal formulations were documented in written and audio-visual format. The survey recorded traditional knowledge on 949 formulations used for 66 human ailments. Five hundred forty six plant products, 42 animal products and 22 organic/inorganic materials were found to be used in these 949 formulations. Five plant species - Zingiber officinale (Zingiberaceae), Cocos nucifera (Arecaceae), Oroxylum indicum (Bignonaceae), Curcuma longa (Zingiberaceae) and Allium sativum (Liliaceae) used by maximum number of Maiba and Maibi in maximum number of formulations. This particular method of documentation keeps traditional knowledge alive. The WHO estimated perspective of traditional medicine across the world. These observations support therapeutic worth of Manipur Traditional medicines (MTM). Having generated a large database in course of this survey, next focus targeted for the scientific justification of MTM with an aim to develop commercially viable products. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  12. An in vitro comparison of tracheostomy tube cuffs

    PubMed Central

    Maguire, Seamus; Haury, Frances; Jew, Korinne

    2015-01-01

    Introduction The Shiley™ Flexible adult tracheostomy tube with TaperGuard™ cuff has been designed through its geometry, materials, diameter, and wall thickness to minimize micro-aspiration of fluids past the cuff and to provide an effective air seal in the trachea while also minimizing the risk of excessive contact pressure on the tracheal mucosa. The cuff also has a deflated profile that may allow for easier insertion through the stoma site. This unique design is known as the TaperGuard™ cuff. The purpose of the observational, in vitro study reported here was to compare the TaperGuard™ taper-shaped cuff to a conventional high-volume low-pressure cylindrical-shaped cuff (Shiley™ Disposable Inner Cannula Tracheostomy Tube [DCT]) with respect to applied tracheal wall pressure, air and fluid sealing efficacy, and insertion force. Methods Three sizes of tracheostomy tubes with the two cuff types were placed in appropriately sized tracheal models and lateral wall pressure was measured via pressure-sensing elements on the inner surface. Fluid sealing performance was assessed by inflating the cuffs within the tracheal models (25 cmH2O), instilling water above the cuff, and measuring fluid leakage past the cuff. To measure air leak, tubes were attached to a test lung and ventilator, and leak was calculated by subtracting the average exhaled tidal volume from the average delivered tidal volume. A tensile test machine was used to measure insertion force for each tube with the cuff deflated to simulate clinical insertion through a stoma site. Results The average pressure exerted on the lateral wall of the model trachea was lower for the taper-shaped cuff than for the cylindrical cuff under all test conditions (P<0.05). The taper-shaped cuff also demonstrated a more even, lower pressure distribution along the lateral wall of the model trachea. The average air and fluid seal performance with the taper-shaped cuff was significantly improved, when compared to the cylindrical-shaped cuff, for each tube size tested (P<0.05). The insertion force for the taper-shaped cuff was ~40% less than that for the cylindrical-shaped cuff. Conclusion In a model trachea, the Shiley™ Flexible Adult tracheostomy tube with TaperGuard™ cuff, when compared to the Shiley™ Disposable Inner Cannula Tracheostomy tube with cylindrical cuff, exerted a lower average lateral wall pressure and a more evenly distributed pressure. In addition, it provided more effective fluid and air seals and required less force to insert. PMID:25960679

  13. Theoretical distribution of gutta-percha within root canals filled using cold lateral compaction based on numeric calculus.

    PubMed

    Min, Yi; Song, Ying; Gao, Yuan; Dummer, Paul M H

    2016-08-01

    This study aimed to present a new method based on numeric calculus to provide data on the theoretical volume ratio of voids when using the cold lateral compaction technique in canals with various diameters and tapers. Twenty-one simulated mathematical root canal models were created with different tapers and sizes of apical diameter, and were filled with defined sizes of standardized accessory gutta-percha cones. The areas of each master and accessory gutta-percha cone as well as the depth of their insertion into the canals were determined mathematically in Microsoft Excel. When the first accessory gutta-percha cone had been positioned, the residual area of void was measured. The areas of the residual voids were then measured repeatedly upon insertion of additional accessary cones until no more could be inserted in the canal. The volume ratio of voids was calculated through measurement of the volume of the root canal and mass of gutta-percha cones. The theoretical volume ratio of voids was influenced by the taper of canal, the size of apical preparation and the size of accessory gutta-percha cones. Greater apical preparation size and larger taper together with the use of smaller accessory cones reduced the volume ratio of voids in the apical third. The mathematical model provided a precise method to determine the theoretical volume ratio of voids in root-filled canals when using cold lateral compaction.

  14. Nonadiabatic tapered optical fiber sensor for measurement of antimicrobial activity of silver nanoparticles against Escherichia coli.

    PubMed

    Zibaii, Mohammad Ismail; Latifi, Hamid; Saeedian, Zahra; Chenari, Zinab

    2014-06-05

    Silver nanoparticles (SNPs) exhibit antibacterial properties via bacterial inactivation and growth inhibition but the mechanism is not yet completely understood. In this study a label free and rapid detection method for study of antimicrobial activity of the SNP against Escherichia coli (E. coli K-12) is investigated using a nonadiabtic tapered fiber optic (NATOF) biosensor. The results show that SNPs interact with bacteria either by anchoring to or penetrating into the bacterial cell layer. These mechanism changes the refractive index (RI) of the tapered region, which in turn lead to the changes in the optical characteristics of the tapered fiber and output signals. With similar conditions for bacteria, the inhibition rate of the E. coli growth was measured by colony counting method as an experimental control and the results were compared with those obtained from the fiber sensor measurements. For SNP concentrations ranging from 0 to 50 μg ml(-1) the inhibition rates of the E. coli growth were measured to be from 1.27 h(-1) to -0.69 h(-1) and from -3.00×10(-3) h(-1) to -1.98×10(-2) h(-1) for colony counting and optical fiber biosensor, respectively. The results demonstrate the potential of the proposed NATOF biosensor as a label free and rapid sensing platform for understanding the mechanism of antibacterial effects of SNPs. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Epithelial self-healing is recapitulated by a 3D biomimetic E-cadherin junction.

    PubMed

    Cohen, Daniel J; Gloerich, Martijn; Nelson, W James

    2016-12-20

    Epithelial monolayers undergo self-healing when wounded. During healing, cells collectively migrate into the wound site, and the converging tissue fronts collide and form a stable interface. To heal, migrating tissues must form cell-cell adhesions and reorganize from the front-rear polarity characteristic of cell migration to the apical-basal polarity of an epithelium. However, identifying the "stop signal" that induces colliding tissues to cease migrating and heal remains an open question. Epithelial cells form integrin-based adhesions to the basal extracellular matrix (ECM) and E-cadherin-mediated cell-cell adhesions on the orthogonal, lateral surfaces between cells. Current biological tools have been unable to probe this multicellular 3D interface to determine the stop signal. We addressed this problem by developing a unique biointerface that mimicked the 3D organization of epithelial cell adhesions. This "minimal tissue mimic" (MTM) comprised a basal ECM substrate and a vertical surface coated with purified extracellular domain of E-cadherin, and was designed for collision with the healing edge of an epithelial monolayer. Three-dimensional imaging showed that adhesions formed between cells, and the E-cadherin-coated MTM resembled the morphology and dynamics of native epithelial cell-cell junctions and induced the same polarity transition that occurs during epithelial self-healing. These results indicate that E-cadherin presented in the proper 3D context constitutes a minimum essential stop signal to induce self-healing. That the Ecad:Fc MTM stably integrated into an epithelial tissue and reduced migration at the interface suggests that this biointerface is a complimentary approach to existing tissue-material interfaces.

  16. Epithelial self-healing is recapitulated by a 3D biomimetic E-cadherin junction

    PubMed Central

    Cohen, Daniel J.; Gloerich, Martijn; Nelson, W. James

    2016-01-01

    Epithelial monolayers undergo self-healing when wounded. During healing, cells collectively migrate into the wound site, and the converging tissue fronts collide and form a stable interface. To heal, migrating tissues must form cell–cell adhesions and reorganize from the front-rear polarity characteristic of cell migration to the apical-basal polarity of an epithelium. However, identifying the "stop signal" that induces colliding tissues to cease migrating and heal remains an open question. Epithelial cells form integrin-based adhesions to the basal extracellular matrix (ECM) and E-cadherin–mediated cell–cell adhesions on the orthogonal, lateral surfaces between cells. Current biological tools have been unable to probe this multicellular 3D interface to determine the stop signal. We addressed this problem by developing a unique biointerface that mimicked the 3D organization of epithelial cell adhesions. This "minimal tissue mimic" (MTM) comprised a basal ECM substrate and a vertical surface coated with purified extracellular domain of E-cadherin, and was designed for collision with the healing edge of an epithelial monolayer. Three-dimensional imaging showed that adhesions formed between cells, and the E-cadherin-coated MTM resembled the morphology and dynamics of native epithelial cell–cell junctions and induced the same polarity transition that occurs during epithelial self-healing. These results indicate that E-cadherin presented in the proper 3D context constitutes a minimum essential stop signal to induce self-healing. That the Ecad:Fc MTM stably integrated into an epithelial tissue and reduced migration at the interface suggests that this biointerface is a complimentary approach to existing tissue–material interfaces. PMID:27930308

  17. Cloning and characterization of an alternatively spliced gene in proximal Xq28 deleted in two patients with intersexual genitalia and myotubular myopathy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laporte, J.; Hu, Ling-Jia; Kretz, C.

    1997-05-01

    We have identified a novel human gene that is entirely deleted in two boys with abnormal genital development and myotubular myopathy (MTM1). The gene, F18, is located in proximal Xq28, approximately 80 kb centromeric to the recently isolated MTM1 gene. Northern analysis of mRNA showed a ubiquitous pattern and suggested high levels of expression in skeletal muscle, brain, and heart. A transcript of 4.6 kb was detected in a range of tissues, and additional alternate forms of 3.8 and 2.6 kb were present in placenta and pancreas, respectively. The gene extends over 100 kb and is composed of at leastmore » seven exons, of which two are non-coding. Sequence analysis of a 4.6-kb cDNA contig revealed two overlapping open reading frames (ORFs) that encode putative proteins of 701 and 424 amino acids, respectively. Two alternative spliced transcripts affecting the large open reading frame were identified that, together with the Northern blot results, suggest that distinct proteins are derived from the gene. No significant homology to other known proteins was detected, but segments of the first ORF encode polyglutamine tracts and proline-rich domains, which are frequently observed in DNA-binding proteins. The F18 gene is a strong candidate for being implicated in the intersexual genitalia present in the two MTM1-deleted patients. The gene also serves as a candidate for other disorders that map to proximal Xq28. 15 refs., 3 figs., 1 tab.« less

  18. Stress Analysis of Columns and Beam Columns by the Photoelastic Method

    NASA Technical Reports Server (NTRS)

    Ruffner, B F

    1946-01-01

    Principles of similarity and other factors in the design of models for photoelastic testing are discussed. Some approximate theoretical equations, useful in the analysis of results obtained from photoelastic tests are derived. Examples of the use of photoelastic techniques and the analysis of results as applied to uniform and tapered beam columns, circular rings, and statically indeterminate frames, are given. It is concluded that this method is an effective tool for the analysis of structures in which column action is present, particularly in tapered beam columns, and in statically indeterminate structures in which the distribution of loads in the structures is influenced by bending moments due to axial loads in one or more members.

  19. REMOTE SENSING AND MOUNTAINTOP MINING

    EPA Science Inventory

    Coal mining is Appalachia has undergone dramatic changes in the past decade. Modem mining practices know as Mountaintop Mining (MTM) and Valley Fills (VF) are at the center of an environmental and legal controversy that has spawned lawsuits and major environmental investigations....

  20. Evaluation of 3M(TM) Scotchlite linear delineation system : final report.

    DOT National Transportation Integrated Search

    2004-09-01

    Major construction projects present many hazards for drivers to negotiate. Detours, lane shifts and confusing curves : present unique challenges to all drivers. At night, the difficulties in negotiating these obstacles are amplified due to : reduced ...

  1. Investigations of Volcanic and Volatile-Driven Processes Northeast of Hellas Basin, Mars

    NASA Astrophysics Data System (ADS)

    Mest, S. C.; Crown, D. A.; Michalski, J.; Chuang, F. C.; Price Blount, K.; Bleamaster, L. F.

    2018-06-01

    We are mapping the geologic units and features in three MTM quadrangles northeast of Hellas basin at 1:1M scale. The area displays evidence for volcanism and widespread volatile-related modification of the surface.

  2. White Sands Missile Range Non-Track Optics: Streamlining the Process of Conducting Business for Improved Customer Support

    DTIC Science & Technology

    2013-12-01

    45 A. METHODOLOGY... 45 B. ANALYSIS .....................................................................................................46 C...digital airborne guidance section MFOM MLRS family of munitions MLRS Multiple Launch Rocket System MMW millimeter wave MT material test MTM

  3. Geologic Map of the MTM -30262 and -30267 Quadrangles, Hadriaca Patera Region of Mars

    USGS Publications Warehouse

    Crown, David A.; Greeley, Ronald

    2007-01-01

    Introduction Mars Transverse Mercator (MTM) -30262 and -30267 quadrangles cover the summit region and east margin of Hadriaca Patera, one of the Martian volcanoes designated highland paterae. MTM -30262 quadrangle includes volcanic deposits from Hadriaca Patera and Tyrrhena Patera (summit northeast of map area) and floor deposits associated with the Dao and Niger Valles canyon systems (south of map area). MTM -30267 quadrangle is centered on the caldera of Hadriaca Patera. The highland paterae are among the oldest, central-vent volcanoes on Mars and exhibit evidence for explosive eruptions, which make a detailed study of their geology an important component in understanding the evolution of Martian volcanism. Photogeologic mapping at 1:500,000-scale from analysis of Viking Orbiter images complements volcanological studies of Hadriaca Patera, geologic investigations of the other highland paterae, and an analysis of the styles and evolution of volcanic activity east of Hellas Planitia in the ancient, cratered highlands of Mars. This photogeologic study is an extension of regional geologic mapping east of Hellas Planitia. The Martian highland paterae are low-relief, areally extensive volcanoes exhibiting central calderas and radial channels and ridges. Four of these volcanoes, Hadriaca, Tyrrhena, Amphitrites, and Peneus Paterae, are located in the ancient cratered terrains surrounding Hellas Planitia and are thought to be located on inferred impact basin rings or related fractures. Based on analyses of Mariner 9 images, Potter (1976), Peterson (1977), and King (1978) suggested that the highland paterae were shield volcanoes formed by eruptions of fluid lavas. Later studies noted morphologic similarities between the paterae and terrestrial ash shields and the lack of primary lava flow features on the flanks of the volcanoes. The degraded appearances of Hadriaca and Tyrrhena Paterae and the apparently easily eroded materials composing their low, broad shields further suggest that the highland paterae are composed predominantly of pyroclastic deposits. Analyses of eruption and flow processes indicate that the distribution of units at Hadriaca and Tyrrhena Paterae is consistent with emplacement by gravity-driven pyroclastic flows. Detailed geologic study of the summit caldera and flanks of Hadriaca Patera is essential to determine the types of volcanic materials exposed, the nature of the processes forming these deposits, and the role of volcanism in the evolution of the cratered highlands that are characteristic of the southern hemisphere of Mars.

  4. Influence of Operator's Experience on the Shaping Ability of Protaper Universal and Waveone Systems: A Comparative Study on Simulated Root Canals.

    PubMed

    Troiano, Giuseppe; Dioguardi, Mario; Cocco, Armando; Giannatempo, Giovanni; Laino, Luigi; Ciavarella, Domenico; Berutti, Elio; Lo Muzio, Lorenzo

    2016-01-01

    To assess the influence of operator experience on: shaping and centering ability, mean preparation time and presence of canal aberrations of ProTaper Universal and WaveOne systems on simulated root canals. Sixty S-shaped canals in resin blocks were assigned to four groups (n=15 for each group). Group1 (Experienced operator, ProTaper), Group2 (Experienced operator, WaveOne), Group3 (Inexperienced operator, ProTaper), Group4 (Inexperienced operator, WaveOne). Photographic method was used to record pre- and post-instrumentations images. After superimposition, it has been evaluated presence of canal aberrations and differences in shaping and centering ability between groups. WaveOne system produced a lower amount of canal aberrations both in the hand of expert than inexpert operators. However, a WaveOne instrument breakage occurred in the hands of an inexperienced operator. No differences have been found in the evaluation of shaping ability with both systematics. Operator's experience doesn't influence the shaping ability of ProTaper and WaveOne systems. Experience factor could influence the centering ability in the use of both the systematics. However, WaveOne Primary reduce the mean preparation time and the presence of canal aberrations.

  5. Apical extrusion of debris in four different endodontic instrumentation systems: A meta-analysis.

    PubMed

    Western, J Sylvia; Dicksit, Daniel Devaprakash

    2017-01-01

    All endodontic instrumentation systems tested so far, promote apical extrusion of debris, which is one of the main causes of postoperative pain, flare ups, and delayed healing. Of this meta-analysis was to collect and analyze in vitro studies quantifying apically extruded debris while using Hand ProTaper (manual), ProTaper Universal (rotary), Wave One (reciprocating), and self-adjusting file (SAF; vibratory) endodontic instrumentation systems and to determine methods which produced lesser extrusion of debris apically. An extensive electronic database search was done in PubMed, Scopus, Cochrane, LILACS, and Google Scholar from inception until February 2016 using the key terms "Apical Debris Extrusion, extruded material, and manual/rotary/reciprocating/SAF systems." A systematic search strategy was followed to extract 12 potential articles from a total of 1352 articles. The overall effect size was calculated from the raw mean difference of weight of apically extruded debris. Statistically significant difference was seen in the following comparisons: SAF < Wave One, SAF < Rotary ProTaper. Apical extrusion of debris was invariably present in all the instrumentation systems analyzed. SAF system seemed to be periapical tissue friendly as it caused reduced apical extrusion compared to Rotary ProTaper and Wave One.

  6. Comparison of apical debris extrusion during root canal preparation using instrumentation techniques with two operating principles: An in vitro study

    PubMed Central

    Verma, Mudita; Meena, N.; Kumari, R. Anitha; Mallandur, Sudhanva; Vikram, R.; Gowda, Vishwas

    2017-01-01

    Aims: The aim of this study was to quantify the debris extruded apically from teeth using rotary and reciprocation instrumentation systems. Subjects and Methods: Eighty extracted human mandibular premolars with single canals and similar lengths were instrumented using ProTaper Universal (40, 06; Dentsply Maillefer, Ballaigues, Switzerland), ProTaper Next (40, 06; Dentsply Maillefer, Ballaigues, Switzerland), WaveOne (40, 06; Dentsply Maillefer, Ballaigues, Switzerland), and Reciproc (R40; VDW GmbH, Munich, Germany). Debris extruded during instrumentation was collected into preweighed Eppendorf tubes, which were then stored in an incubator at 70°C for 5 days. The final weight of the Eppendorf tubes with the extruded debris was calculated after obtaining the mean of three consecutive weights obtained for each tube. Statistical Analysis Used: Statistical analysis was performed using SPSS version 16.0 software. The groups were compared using the Kruskal–Wallis test for all variables. Results: There was no statistically significant difference between the groups (P = 0.1114). However, the ProTaper Universal group produced more extrusion and ProTaper Next produced least debris extrusion among the instrument groups (P > 0.05). Conclusions: All instrumentation techniques were associated with extruded debris. PMID:28855755

  7. Mismatch Considerations in Excitation of Single-Mode Circular Core Parabolic Index Fiber by Laser Diode via Upside Down Tapered Hemispherical Microlens on the Tip of the Fiber

    NASA Astrophysics Data System (ADS)

    Das, Bishuddhananda; Middya, Tapas Ranjan; Gangopadhyay, Sankar

    2017-12-01

    We report the theoretical investigation of the coupling optics involving laser diode to single-mode circular core parabolic index fiber via upside down tapered hemispherical microlens on the tip of the fiber in the presence of possible transverse and angular mismatches. Using the relevant ABCD matrix for such tapered hemispherical microlens, we formulate analytical expressions for the coupling efficiencies in the presence of the said two mismatches. Further, the transmitted spot size of the source via the hemispherical lens and the tapered region should match with the spot size of the fiber for obtaining maximum coupling. The investigations have been made for two practical wavelengths, namely 1.3 and 1.5 μm in order to find the tolerance of this coupling device with respect to the said kinds of mismatches at the concerned wavelengths. Although our simple method predicts the concerned coupling optics excellently, the evaluation of the concerned efficiencies and associated losses involve little computations. Thus this user-friendly technique and also the results found thereof will benefit the designers and packagers who are working in the field of optical technology.

  8. Optimizing treatment with tumour necrosis factor inhibitors in rheumatoid arthritis-a proof of principle and exploratory trial: is dose tapering practical in good responders?

    PubMed

    Ibrahim, Fowzia; Lorente-Cánovas, Beatriz; Doré, Caroline J; Bosworth, Ailsa; Ma, Margaret H; Galloway, James B; Cope, Andrew P; Pande, Ira; Walker, David; Scott, David L

    2017-11-01

    RA patients receiving TNF inhibitors (TNFi) usually maintain their initial doses. The aim of the Optimizing Treatment with Tumour Necrosis Factor Inhibitors in Rheumatoid Arthritis trial was to evaluate whether tapering TNFi doses causes loss of clinical response. We enrolled RA patients receiving etanercept or adalimumab and a DMARD with DAS28 under 3.2 for over 3 months. Initially (months 0-6) patients were randomized to control (constant TNFi) or two experimental groups (tapering TNFi by 33 or 66%). Subsequently (months 6-12) control subjects were randomized to taper TNFi by 33 or 66%. Disease flares (DAS28 increasing ⩾0.6 with at least one additional swollen joint) were the primary outcome. Two hundred and forty-four patients were screened, 103 randomized and 97 treated. In months 0-6 there were 8/50 (16%) flares in controls, 3/26 (12%) with 33% tapering and 6/21 (29%) with 66% tapering. Multivariate Cox analysis showed time to flare was unchanged with 33% tapering but was reduced with 66% tapering compared with controls (adjusted hazard ratio 2.81, 95% CI: 0.99, 7.94; P = 0.051). Analysing all tapered patients after controls were re-randomized (months 6-12) showed differences between groups: there were 6/48 (13%) flares with 33% tapering and 14/39 (36%) with 66% tapering. Multivariate Cox analysis showed 66% tapering reduced time to flare (adjusted hazard ratio 3.47, 95% CI: 1.26, 9.58; P = 0.016). Tapering TNFi by 33% has no impact on disease flares and appears practical in patients in sustained remission and low disease activity states. EudraCT, https://www.clinicaltrialsregister.eu, 2010-020738-24; ISRCTN registry, https://www.isrctn.com, 28955701. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Rheumatology.

  9. Effects of Prosthesis Stem Tapers on Stress Distribution of Cemented Hip Arthroplasty

    NASA Astrophysics Data System (ADS)

    Abdullah, Abdul Halim; Nor, Mohd Asri Mohd; Saman, Alias Mohd; Tamin, Mohd Nasir; Kadir, Mohammed Rafiq Abdul

    2010-10-01

    Aseptic loosening effects are critical issues in encouraging long term stability of cemented hip arthroplasty. Stress shielding is believed to be an important factor that contributes to the aseptic loosening problems. The numerous changes in the prosthesis stem design are intended to minimize the stress shielding and aseptic loosening problems and to improve the long term performance of the implants. In this study, the stress distribution in cemented hip arthroplasty is established using finite element method. The taper of the prosthesis is designed to be 3° at anterior/posterior, 3° at medial/lateral and 10° from wide lateral to narrow medial. Major muscle loads and contact forces are simulated for walking (toe-off phase) and stair climbing load cases. Effects of prosthesis stem tapers on the resulting stress distribution are investigated. Results show that compressive stress dominates in the medial plane while tensile stress in the lateral plane of the femur. The corresponding stress levels of intact femur for walking and stair-climbing load cases are 22 and 29 MPa, respectively. The magnitude of Tresca stress for the THA femur in stair-climbing load case remains higher in the region of 85 MPa while the walking load case induces around 40 MPa. The stress range in the straight and single taper stem prosthesis is lower than 260 MPa, while localized Tresca stress is in the order of the yield strength of Ti-6Al-4V alloy for double and triple taper stem design.

  10. Tapered Microfluidic for Continuous Micro-Object Separation Based on Hydrodynamic Principle.

    PubMed

    Ahmad, Ida Laila; Ahmad, Mohd Ridzuan; Takeuchi, Masaru; Nakajima, Masahiro; Hasegawa, Yasuhisa

    2017-12-01

    Recent advances in microfluidic technologies have created a demand for a simple and efficient separation intended for various applications such as food industries, biological preparation, and medical diagnostic. In this paper, we report a tapered microfluidic device for passive continuous separation of microparticles by using hydrodynamic separation. By exploiting the hydrodynamic properties of the fluid flow and physical characteristics of micro particles, effective size based separation is demonstrated. The tapered microfluidic device has widening geometries with respect to specific taper angle which amplify the sedimentation effect experienced by particles of different sizes. A mixture of 3-μm and 10-μm polystyrene microbeads are successfully separated using 20° and 25° taper angles. The results obtained are in agreement with three-dimensional finite element simulation conducted using Abaqus 6.12. Moreover, the feasibility of this mechanism for biological separation is demonstrated by using polydisperse samples consists of 3-μm polystyrene microbeads and human epithelial cervical carcinoma (HeLa) cells. 98% of samples purity is recovered at outlet 1 and outlet 3 with flow rate of 0.5-3.0 μl/min. Our device is interesting despite adopting passive separation approach. This method enables straightforward, label-free, and continuous separation of multiparticles in a stand-alone device without the need for bulky apparatus. Therefore, this device may become an enabling technology for point of care diagnosis tools and may hold potential for micrototal analysis system applications.

  11. Evaluation of the Painful Dual Taper Modular Neck Stem Total Hip Arthroplasty: Do They All Require Revision?

    PubMed

    Kwon, Young-Min

    2016-07-01

    Although dual taper modular-neck total hip arthroplasty (THA) design with additional neck-stem modularity has the potential to optimize hip biomechanical parameters by facilitating adjustments of leg length, femoral neck version and offset, there is increasing concern regarding this stem design as a result of the growing numbers of adverse local tissue reactions due to fretting and corrosion at the neck-stem taper junction. Implant factors such as taper cone angle, taper surface roughness, taper contact area, modular neck taper metallurgy, and femoral head size play important roles in influencing extent of taper corrosion. There should be a low threshold to conduct a systematic clinical evaluation of patients with dual-taper modular-neck stem THA using systematic risk stratification algorithms as early recognition and diagnosis will ensure prompt and appropriate treatment. Although specialized tests such as metal ion analysis and cross-sectional imaging modalities such as metal artifact reduction sequence magnetic resonance imaging (MARS MRI) are useful in optimizing clinical decision-making, overreliance on any single investigative tool in the clinical decision-making process for revision surgery should be avoided. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Fracture resistance of structurally compromised and normal endodontically treated teeth restored with different post systems: An in vitro study

    PubMed Central

    Mortazavi, Vajihesadat; Fathi, Mohammadhossein; Katiraei, Najmeh; Shahnaseri, Shirin; Badrian, Hamid; Khalighinejad, Navid

    2012-01-01

    Background: With the aim of developing methods that could increase the fracture resistance of structurally compromised endodontically treated teeth, this study was conducted to compare the effect of three esthetic post systems on the fracture resistance and failure modes of structurally compromised and normal roots. Materials and Methods: Forty five extracted and endodontically treated maxillary central teeth were assigned to 5 experimental groups (n=9). In two groups, the post spaces were prepared with the corresponding drills of the post systems to be restored with double taper light posts (DT.Light-Post) (group DT.N) and zirconia posts (Cosmopost) (group Zr.N). In other 3 groups thin wall canals were simulated to be restored with Double taper Light posts (DT.W), double taper Light posts and Ribbond fibers (DT+R.W) and Zirconia posts (Zr.W). After access cavity restoration and thermocycling, compressive load was applied and the fracture strength values and failure modes were evaluated. Data were analyzed using two-way ANOVA, Tukey and Fisher exact tests (P<0.05). Results: The mean failure loads (N) were 678.56, 638.22, 732.44, 603.44 and 573.67 for groups DT.N, Zr.N, DT.W, DT+R.W and Zr.w respectively. Group DT+R.W exhibited significantly higher resistance to fracture compared to groups Zr.N, DT.W and Zr.w (P<0.05). A significant difference was detected between groups DT.N and Zr.W (P=0.027). Zirconia posts showed significantly higher root fracture compared to fiber posts (P=0.004). Conclusion: The structurally compromised teeth restored with double taper light posts and Ribbond fibers showed the most fracture resistance and their strengths were comparable to those of normal roots restored with double taper light posts. More desirable fracture patterns were observed in teeth restored with fiber posts. PMID:22623936

  13. Development and evaluation of needle trap device geometry and packing methods for automated and manual analysis.

    PubMed

    Warren, Jamie M; Pawliszyn, Janusz

    2011-12-16

    For air/headspace analysis, needle trap devices (NTDs) are applicable for sampling a wide range of volatiles such as benzene, alkanes, and semi-volatile particulate bound compounds such as pyrene. This paper describes a new NTD that is simpler to produce and improves performance relative to previous NTD designs. A NTD utilizing a side-hole needle used a modified tip, which removed the need to use epoxy glue to hold sorbent particles inside the NTD. This design also improved the seal between the NTD and narrow neck liner of the GC injector; therefore, improving the desorption efficiency. A new packing method has been developed and evaluated using solvent to pack the device, and is compared to NTDs prepared using the previous vacuum aspiration method. The slurry packing method reduced preparation time and improved reproducibility between NTDs. To evaluate the NTDs, automated headspace extraction was completed using benzene, toluene, ethylbenzene, p-xylene (BTEX), anthracene, and pyrene (PAH). NTD geometries evaluated include: blunt tip with side-hole needle, tapered tip with side-hole needle, slider tip with side-hole, dome tapered tip with side-hole and blunt with no side-hole needle (expanded desorptive flow). Results demonstrate that the tapered and slider tip NTDs performed with improved desorption efficiency. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. Biconically tapered fiber optic probes for rapid label-free immunoassays.

    PubMed

    Miller, John; Castaneda, Angelica; Lee, Kun Ho; Sanchez, Martin; Ortiz, Adrian; Almaz, Ekrem; Almaz, Zuleyha Turkoglu; Murinda, Shelton; Lin, Wei-Jen; Salik, Ertan

    2015-04-01

    We report use of U-shaped biconically tapered optical fibers (BTOF) as probes for label-free immunoassays. The tapered regions of the sensors were functionalized by immobilization of immunoglobulin-G (Ig-G) and tested for detection of anti-IgG at concentrations of 50 ng/mL to 50 µg/mL. Antibody-antigen reaction creates a biological nanolayer modifying the waveguide structure leading to a change in the sensor signal, which allows real-time monitoring. The kinetics of the antibody (mouse Ig-G)-antigen (rabbit anti-mouse IgG) reactions was studied. Hydrofluoric acid treatment makes the sensitive region thinner to enhance sensitivity, which we confirmed by experiments and simulations. The limit of detection for the sensor was estimated to be less than 50 ng/mL. Utilization of the rate of the sensor peak shift within the first few minutes of the antibody-antigen reaction is proposed as a rapid protein detection method.

  15. Tapered fiber based Brillouin random fiber laser and its application for linewidth measurement.

    PubMed

    Gao, Song; Zhang, Liang; Xu, Yanping; Lu, Ping; Chen, Liang; Bao, Xiaoyi

    2016-12-12

    A one-end pumping Brillouin random fiber laser (BRFL) based on a 5-km tapered fiber (TF) is demonstrated. The enhanced Rayleigh scattering and the increased power density from tapering in the TF provide good directionality and a high degree of coherent feedback. Both the transmitting and TF enhanced Rayleigh scattered pump lights formed effective bi-direction pumping for the Brillouin gain in the standing cavity configuration in the distributed way as the gain and random feedback in the same fiber. The linewidth of the laser shows ~1.17 kHz while the relative intensity noise (RIN) has been verified to be suppressed comparing with that of the two-end pumping of the standard single mode fiber (SMF). Furthermore, utilizing the proposed laser, a high-resolution (~kHz) linewidth measurement method is demonstrated without long delay fiber (>100km) and extra frequency shifter thanks to the acoustic frequency shift from fiber itself.

  16. Peripheral Nerve Stimulation Characteristics of an Asymmetric Head-Only Gradient Coil Compatible with a High-Channel-Count Receiver Array

    PubMed Central

    Lee, Seung-Kyun; Mathieu, Jean-Baptiste; Graziani, Dominic; Piel, Joseph; Budesheim, Eric; Fiveland, Eric; Hardy, Christopher J.; Tan, Ek Tsoon; Amm, Bruce; Foo, Thomas K.-F; Bernstein, Matt A.; Huston, John; Shu, Yunhong; Schenck, John F.

    2015-01-01

    Purpose To characterize peripheral nerve stimulation (PNS) of an asymmetric head-only gradient coil that is compatible with a commercial high-channel-count receive-only array. Methods Two prototypes of an asymmetric head-only gradient coil set, with 42-cm inner diameter, were constructed for brain imaging at 3T with maximum performance specifications of up to 85 mT/m and 708 T/m/s. 24 volunteer tests were performed to measure PNS thresholds with the transverse (X, left/right; Y, anterior/posterior) gradient coils of both prototypes. 14 volunteers were also tested for the Z-gradient PNS in the second prototype, and were additionally scanned with high-slew-rate EPI immediately after the PNS tests. Results For both prototypes, the Y-gradient PNS threshold was markedly higher than the X-gradient. The Z-gradient threshold was intermediate between those for the X- and Y-coils. Out of the 24 volunteer subjects, only two experienced Y-gradient PNS at 80 mT/m, 500 T/m/s. All volunteers underwent the EPI scan without PNS when the readout direction was set to A/P. Conclusion Measured PNS characteristics of asymmetric head-only gradient coil prototypes indicate that such coils, especially in the A/P direction, can be used for fast EPI readout in high-performance neuroimaging scans with substantially reduced PNS concerns compared to conventional whole-body gradient coils. PMID:26628078

  17. Comparative evaluation of apically extruded debris with V-Taper, ProTaper Next, and the Self-adjusting File systems.

    PubMed

    Vyavahare, Nishant K; Raghavendra, Srinidhi Surya; Desai, Niranjan N

    2016-01-01

    Complete cleaning of the root canal is the goal for ensuring success in endodontics. Removal of debris plays an important role in achieving this goal. In spite of advancements in instrument design, apical extrusion of debris remains a source of inflammation in the periradicular region. To comparatively evaluate the amount of apically extruded debris with V-Taper, ProTaper Next, and the self-adjusting File (SAF) system. Sixty-four extracted human mandibular teeth with straight root canals were taken. Access openings were done and working length determined. The samples were randomly divided into three groups: Group I - V-Taper files (n = 20), Group II - ProTaper Next (n = 20), Group III - SAF (n = 20). Biomechanical preparation was completed and the debris collected in vials to be quantitatively determined. The data obtained was statistically analyzed using ANOVA and post hoc Tukey's test. All the specimens showed apical debris extrusion. SAF showed significantly less debris extrusion compared to V-Taper and ProTaper Next (P < 0.001). Among Groups I and II, ProTaper Next showed lesser debris extrusion as compared to V-Taper, but it was not significant (P = 0.124). The SAF showed least amount of apical debris extrusion when compared to newer rotary endodontic instruments. This indicates that the incidence of inter-treatment flare-ups due to debris extrusion would be less with the SAF.

  18. Investigation of evanescent coupling between tapered fiber and a multimode slab waveguide.

    PubMed

    Dong, Shaofei; Ding, Hui; Liu, Yiying; Qi, Xiaofeng

    2012-04-01

    A tapered fiber-slab waveguide coupler (TFSC) is proposed in this paper. Both the numerical analysis based on the beam propagation method and experiments are used for investigating the dependencies of TFSC transmission features on their geometric parameters. From the simulations and experimental results, the rules for fabricating a TFSC with low transmission loss and sharp resonant spectra by optimizing the configuration parameters are presented. The conclusions derived from our work may provide helpful references for optimally designing and fabricating TFSC-based devices, such as sensors, wavelength filters, and intensity modulators.

  19. Effect of reciprocating file motion on microcrack formation in root canals: an SEM study.

    PubMed

    Ashwinkumar, V; Krithikadatta, J; Surendran, S; Velmurugan, N

    2014-07-01

    To compare dentinal microcrack formation whilst using Ni-Ti hand K-files, ProTaper hand and rotary files and the WaveOne reciprocating file. One hundred and fifty mandibular first molars were selected. Thirty teeth were left unprepared and served as controls, and the remaining 120 teeth were divided into four groups. Ni-Ti hand K-files, ProTaper hand files, ProTaper rotary files and WaveOne Primary reciprocating files were used to prepare the mesial canals. Roots were then sectioned 3, 6 and 9 mm from the apex, and the cut surface was observed under scanning electron microscope (SEM) and checked for the presence of dentinal microcracks. The control and Ni-Ti hand K-files groups were not associated with microcracks. In roots prepared with ProTaper hand files, ProTaper rotary files and WaveOne Primary reciprocating files, dentinal microcracks were present. There was a significant difference between control/Ni-Ti hand K-files group and ProTaper hand files/ProTaper rotary files/WaveOne Primary reciprocating file group (P < 0.001) with ProTaper rotary files producing the most microcracks. No significant difference was observed between teeth prepared with ProTaper hand files and WaveOne Primary reciprocating files. ProTaper rotary files were associated with significantly more microcracks than ProTaper hand files and WaveOne Primary reciprocating files. Ni-Ti hand K-files did not produce microcracks at any levels inside the root canals. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  20. Mobile Health Technology Using a Wearable Sensorband for Female College Students With Problem Drinking: An Acceptability and Feasibility Study

    PubMed Central

    Silverman, Michelle; Sherpa, Dawa Phuti; Naegle, Madeline A; Kim, Hyorim; Coffman, Donna L; Ferdschneider, Marcy

    2017-01-01

    Background An increasing number of mobile app interventions have been developed for problem drinking among college students; however, few studies have examined the integration of a mobile app with continuous physiological monitoring and alerting of affective states related to drinking behaviors. Objective The aim of this paper was to evaluate the acceptability and feasibility of Mind the Moment (MtM), a theoretically based intervention for female college students with problem drinking that combines brief, in-person counseling with ecological momentary intervention (EMI) on a mobile app integrated with a wearable sensorband. Methods We recruited 10 non-treatment seeking, female undergraduates from a university health clinic who scored a 3 or higher on the Alcohol Use Disorders Identification Test–Consumption (AUDIT-C) to participate in this pilot study. Study activities involved an in-person baseline intake and 1 follow-up assessment, 2 in-person alcohol brief intervention counseling sessions, and use of MtM technology components (sensorband and EMI on a mobile app) for approximately 3-4 weeks. The intervention used motivational interviewing (MI) and cognitive behavioral therapy (CBT) strategies for reducing risks associated with drinking. We used both qualitative and quantitative assessments to measure acceptability of the intervention and feasibility of delivery. Use patterns of the sensorband and mobile app were also collected. Results Quantitative and qualitative data indicated high levels of acceptability for the MtM intervention. Altogether, participants made reports on the app on 26.7% (78/292) the days the technology was available to them and completed a total of 325 reports with wide variation between participants. Qualitative findings indicated that sensorband-elicited alerts promoted an increase in awareness of thoughts, feelings, and behaviors related to current environmental stressors and drinking behaviors in theoretically meaningful ways. Specific challenges related to functionality and form of the sensorband were identified. Conclusions Delivering intervention material “just-in-time,” at the moment participants need to use behavioral strategies has great potential to individualize behavioral interventions for reducing problem drinking and other health behaviors. These findings provide initial evidence for the promise of wearable sensors for increasing potency of theoretically grounded mobile health interventions and point to directions for future research and uptake of these technologies. PMID:28687533

  1. Electromagnetic field tapering using all-dielectric gradient index materials.

    PubMed

    Yi, Jianjia; Piau, Gérard-Pascal; de Lustrac, André; Burokur, Shah Nawaz

    2016-07-28

    The concept of transformation optics (TO) is applied to control the flow of electromagnetic fields between two sections of different dimensions through a tapering device. The broadband performance of the field taper is numerically and experimentally validated. The taper device presents a graded permittivity profile and is fabricated through three-dimensional (3D) polyjet printing technology using low-cost all-dielectric materials. Calculated and measured near-field mappings are presented in order to validate the proposed taper. A good qualitative agreement is obtained between full-wave simulations and experimental tests. Such all-dielectric taper paves the way to novel types of microwave devices that can be easily fabricated through low-cost additive manufacturing processes.

  2. In-line optical fiber sensors based on cladded multimode tapered fibers.

    PubMed

    Villatoro, Joel; Monzón-Hernández, David; Luna-Moreno, Donato

    2004-11-10

    The use of uniform-waist cladded multimode tapered optical fibers is demonstrated for evanescent wave spectroscopy and sensors. The tapering is a simple, low-loss process and consists of stretching the fiber while it is being heated with an oscillating flame torch. As examples, a refractive-index sensor and a hydrogen sensor are demonstrated by use of a conventional graded-index multimode optical fiber. Also, absorbance spectra are measured while the tapers are immersed in an absorbing liquid. It is found experimentally that the uniform waist is the part of the taper that contributes most to the sensor sensitivity. The taper waist diameter may also be used to adjust the sensor dynamic range.

  3. Tapered enlarged ends in multimode optical fibers.

    PubMed

    Brenci, M; Falciai, R; Scheggi, A M

    1982-01-15

    Radiation characteristics of multimode fibers with enlarged tapers were investigated on a number of samples obtained by varying the fiber drawing speed with a given law corresponding to a prefixed taper profile. The characterization of the fibers was made by near- and far-field intensity pattern measurements as well as by measuring the losses introduced by the taper. With a suitable choice of parameters the taper constitutes a reasonable low-loss component useful, for example, for either efficient coupling to large-spot high-power density sources or connecting fibers of different sizes. Conversely at the exit of the fiber the taper can be used for beam shaping which is of interest for mechanical or surgical applications.

  4. Optical/Infrared Properties of Atmospheric Aerosols with an In-Situ, Multi-Wavelength, Multichannel Nephelometer System.

    DTIC Science & Technology

    1985-04-01

    from any angle of approach. An angular impetus is imparted to the particle 25 7. motion via the eight evenly spaced entrance vanes. As the particles...measurement cycle. 2 f.. 27 VA NE S M= VANE ASSEMBLY BASE IN SECT SCREEN TUBE PROTECTIVE CPLUGHOUSING HOUSING-DEFLECTORAEOYMIINT SPACING PHAEO YNAI N...AERODYNAMIC FLOW DEFLECTOR OUTER TUJBE TAPERED p. Figure 3 r Wedding PM 1 0 Inlet [I]J 28 . .I .. II | I I J . 1 _1 ! I 7 I ! . ?. . . - 120 -- WEDDING INLET

  5. 77 FR 45588 - Tapered Roller Bearings and Parts Thereof, Finished and Unfinished, From the People's Republic of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-01

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-601] Tapered Roller Bearings and... new shipper review (``NSR'') of the antidumping duty order on tapered roller bearings from the People... The notice announcing the antidumping duty order on tapered roller bearings from the PRC was published...

  6. 76 FR 6397 - Tapered Roller Bearings and Parts Thereof, Finished and Unfinished From the People's Republic of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-04

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-601] Tapered Roller Bearings and... on tapered roller bearings (``TRBs'') from the People's Republic of China (``PRC'') meets the... published in the Federal Register on June 15, 1987. See Antidumping Duty Order; Tapered Roller Bearings and...

  7. 76 FR 45777 - Tapered Roller Bearings and Parts Thereof, Finished and Unfinished From the People's Republic of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-01

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-601] Tapered Roller Bearings and... tapered roller bearings (``TRBs'') from the People's Republic of China (``PRC'') meets the statutory and... Register on June 15, 1987. See Antidumping Duty Order; Tapered Roller Bearings and Parts Thereof, Finished...

  8. Simple Expressions for the Design of Linear Tapers in Overmoded Corrugated Waveguides

    DOE PAGES

    Schaub, S. C.; Shapiro, M. A.; Temkin, R. J.

    2015-08-16

    In this paper, simple analytical formulae are presented for the design of linear tapers with very low mode conversion loss in overmoded corrugated waveguides. For tapers from waveguide radius a2 to a1, with a11a 2/λ. Here, λ is the wavelength of radiation. The fractional loss of the HE 11 mode in an optimized taper is 0.0293(a 2-a 1) 4/amore » $$2\\atop{1}$$1a$$2\\atop{2}$$. These formulae are accurate when a2≲2a 1. Slightly more complex formulae, accurate for a 2≤4a 1, are also presented in this paper. The loss in an overmoded corrugated linear taper is less than 1 % when a 2≤2.12a 1 and less than 0.1 % when a 2≤1.53a 1. The present analytic results have been benchmarked against a rigorous mode matching code and have been found to be very accurate. The results for linear tapers are compared with the analogous expressions for parabolic tapers. Finally, parabolic tapers may provide lower loss, but linear tapers with moderate values of a 2/a 1 may be attractive because of their simplicity of fabrication.« less

  9. Enhancing sensitivity of biconical tapered fiber sensors with multiple passes through the taper

    NASA Astrophysics Data System (ADS)

    Cohoon, Gregory; Boyter, Chris; Errico, Michael; Vandervoort, Kurt; Salik, Ertan

    2010-03-01

    A single biconical fiber taper is a simple and low-cost yet powerful sensor. With a distinct strength in refractive index (RI) sensing, biconical tapered fiber sensors can find their place in handheld sensor platforms, especially as biosensors that are greatly needed in health care, environmental protection, food safety, and biodefense. We report doubling of sensitivity for these sensors with two passes through the tapered region, which becomes possible through the use of sensitive and high-dynamic-range photodetectors. In a proof-of-principle experiment, we measured transmission through the taper when it was immersed in isopropyl alcohol-water mixtures of varying concentrations, in which a thin gold layer at the tip of the fiber acted as a mirror enabling two passes through the tapered region. This improved the sensitivity from 0.43 dB/vol % in the single-pass case to 0.78 dB/vol % with two passes through the taper. The refractive index detection limit was estimated to be ~1.2×10-5 RI units (RIU) and ~0.6×10-5 RIU in the single- and double-pass schemes, respectively. We predict that further enhancement of sensitivity may be achieved with a higher number of passes through the taper.

  10. Endodontic shaping performance using nickel-titanium hand and motor ProTaper systems by novice dental students.

    PubMed

    Tu, Ming-Gene; Chen, San-Yue; Huang, Heng-Li; Tsai, Chi-Cheng

    2008-05-01

    Preparing a continuous tapering conical shape and maintaining the original shape of a canal are obligatory in root canal preparation. The purpose of this study was to compare the shaping performance in simulated curved canal resin blocks of the same novice dental students using hand-prepared and engine-driven nickel-titanium (NiTi) rotary ProTaper instruments in an endodontic laboratory class. Twenty-three fourth-year dental students attending China Medical University Dental School prepared 46 simulated curved canals in resin blocks with two types of NiTi rotary systems: hand and motor ProTaper files. Composite images were prepared for estimation. Material removed, canal width and canal deviation were measured at five levels in the apical 4 mm of the simulated curved canals using AutoCAD 2004 software. Data were analyzed using Wilcoxon's rank-sum test. The hand ProTaper group cut significantly wider than the motor rotary ProTaper group in the outer wall, except for the apical 0 mm point. The total canal width was cut significantly larger in the hand group than in the motor group. There was no significant difference between the two groups in centering canal shape, except at the 3 mm level. These findings show that the novice students prepared the simulated curved canal that deviated more outwardly from apical 1 mm to 4 mm using the hand ProTaper. The ability to maintain the original curvature was better in the motor rotary ProTaper group than in the hand ProTaper group. Undergraduate students, if following the preparation sequence carefully, could successfully perform canal shaping by motor ProTaper files and achieve better root canal geometry than by using hand ProTaper files within the same teaching and practicing sessions.

  11. Ongoing compression triggered exhumation of the orogenic crust in the Variscan Maures-Tanneron Massif, France - Geological arguments and thermo-mechanical tests

    NASA Astrophysics Data System (ADS)

    Gerbault, Muriel; Schneider, Julie; Reverso-Peila, Alexandre; Corsini, Michel

    2016-04-01

    The Maures-Tanneron Massif (MTM), together with Corsica and Sardinia, hosted the South-Eastern Variscan belt and record a continuous evolution from continental collision to exhumation. We present a synthesis of the available geological and geochronogical data that explores the transition from convergence to perpendicular Permean extension in the MTM (at ~ 325 Ma ± 25 My). The migmatitic Internal Zone that composes the Western MTM displays structural clues such as backthrusting and magmatic foliations, and metamorphic data indicating exhumation of deep seated partially molten rocks at an apparent heating rate of 1-2 °C/km/My from ca. 345 Ma to 320 Ma. This suggests vertical advective heat transport during continued N140° convergence (D2 phase). In contrast at the same time, the low grade External zone composing the Eastern part of the MTM recorded exhumation of more conductive patterns at an apparent rate of 0.3-0.6 °C/km/My. It is only from ca. 320 Ma that transcurrent motion dominates in the Internal zone and progressively leaves way to N-S strecthing (D3 phase), indicative of orogenic collapse and extension and in asociation with emplacement of larger volumes of magmatism in the crust. Thermo-mechanical modeling complements this synthesis in order to highlight the conditions under which deep seated HP units could melt and massively start to exhume during maintained convergence (phase D2). Accounting for temperature dependent elasto-visco-plastic rheologies, our models explore the dynamics of an orogenic prism starting from a dis-equilibrated state just after slab break-off or delamination, at ca. 350 Ma. We simulate the development of gravitational instabilities in partially melting crust, a process that is already well known to depend on strain-rate, heat sources and strength layering. In order to reproduce the exhumation patterns of rocks from ~50 km depth over the appropriate time-scale (>20 My) and spatial extent (>100 km), a best fit was obtained with a mean convergence rate of 0.5 cm/yr and no exceptional surface processes. Internal heating has a crucial effect and mostly resulted from the radiogenic decay of stacked felsic crustal units. However alternation with mafic units is also necessary in order to prevent lateral spreading of the orogeny. A low viscosity partially molten (eg. felsic) crust also permits mechanical decoupling of surface deformation from the deeper mantle domains, thus reducing the differences due to either a shallow asthenosphere or a competent mantle lithosphere under the orogeny. A shallow asthenosphere produces too warm and fast exhumation. The bulk viscosity of the partially molten orogenic crust controls the timing of exhumation, pointing to the need for further constraints to link the behaviour at different scales of partially molten crust. The MTM witnesses the typical competition between far-field plate convergence and internal body forces, and we plead for a subsequent progressive evolution of transpression to perpendicular extension (still to be tackled with 3D modeling).

  12. Wind blade spar cap and method of making

    DOEpatents

    Mohamed, Mansour H [Raleigh, NC

    2008-05-27

    A wind blade spar cap for strengthening a wind blade including an integral, unitary three-dimensional woven material having a first end and a second end, corresponding to a root end of the blade and a tip end of the blade, wherein the material tapers in width from the first to the second end while maintaining a constant thickness and decreasing weight therebetween, the cap being capable of being affixed to the blade for providing increased strength with controlled variation in weight from the root end to the tip end based upon the tapered width of the material thereof. The present inventions also include the method of making the wind blade spar cap and a wind blade including the wind blade spar cap.

  13. WGM resonators for studying orbital angular momentum of a photon, and methods

    NASA Technical Reports Server (NTRS)

    Matsko, Andrey B. (Inventor); Savchenkov, Anatoliy A. (Inventor); Maleki, Lute (Inventor); Strekalov, Dmitry V. (Inventor)

    2009-01-01

    An optical system, device, and method that are capable of generating high-order Bessel beams and determining the orbital angular momentum of at least one of the photons of a Bessel beam are provided. The optical system and device include a tapered waveguide having an outer surface defined by a diameter that varies along a longitudinal axis of the waveguide from a first end to an opposing second end. The optical system and device include a resonator that is arranged in optical communication with the first end of the tapered waveguide such that an evanescent field emitted from (i) the waveguide can be coupled with the resonator, or (ii) the resonator can be coupled with the waveguide.

  14. Nanoscale array structures suitable for surface enhanced raman scattering and methods related thereto

    DOEpatents

    Bond, Tiziana C.; Miles, Robin; Davidson, James C.; Liu, Gang Logan

    2014-07-22

    Methods for fabricating nanoscale array structures suitable for surface enhanced Raman scattering, structures thus obtained, and methods to characterize the nanoscale array structures suitable for surface enhanced Raman scattering. Nanoscale array structures may comprise nanotrees, nanorecesses and tapered nanopillars.

  15. Nanoscale array structures suitable for surface enhanced raman scattering and methods related thereto

    DOEpatents

    Bond, Tiziana C.; Miles, Robin; Davidson, James C.; Liu, Gang Logan

    2015-07-14

    Methods for fabricating nanoscale array structures suitable for surface enhanced Raman scattering, structures thus obtained, and methods to characterize the nanoscale array structures suitable for surface enhanced Raman scattering. Nanoscale array structures may comprise nanotrees, nanorecesses and tapered nanopillars.

  16. Nanoscale array structures suitable for surface enhanced raman scattering and methods related thereto

    DOEpatents

    Bond, Tiziana C; Miles, Robin; Davidson, James; Liu, Gang Logan

    2015-11-03

    Methods for fabricating nanoscale array structures suitable for surface enhanced Raman scattering, structures thus obtained, and methods to characterize the nanoscale array structures suitable for surface enhanced Raman scattering. Nanoscale array structures may comprise nanotrees, nanorecesses and tapered nanopillars.

  17. Moment method analysis of linearly tapered slot antennas

    NASA Technical Reports Server (NTRS)

    Koeksal, Adnan

    1993-01-01

    A method of moments (MOM) model for the analysis of the Linearly Tapered Slot Antenna (LTSA) is developed and implemented. The model employs an unequal size rectangular sectioning for conducting parts of the antenna. Piecewise sinusoidal basis functions are used for the expansion of conductor current. The effect of the dielectric is incorporated in the model by using equivalent volume polarization current density and solving the equivalent problem in free-space. The feed section of the antenna including the microstripline is handled rigorously in the MOM model by including slotline short circuit and microstripline currents among the unknowns. Comparison with measurements is made to demonstrate the validity of the model for both the air case and the dielectric case. Validity of the model is also verified by extending the model to handle the analysis of the skew-plate antenna and comparing the results to those of a skew-segmentation modeling results of the same structure and to available data in the literature. Variation of the radiation pattern for the air LTSA with length, height, and taper angle is investigated, and the results are tabulated. Numerical results for the effect of the dielectric thickness and permittivity are presented.

  18. Human evaluation in association to the mathematical analysis of arch forms: Two-dimensional study.

    PubMed

    Zabidin, Nurwahidah; Mohamed, Alizae Marny; Zaharim, Azami; Marizan Nor, Murshida; Rosli, Tanti Irawati

    2018-03-01

    To evaluate the relationship between human evaluation of the dental-arch form, to complete a mathematical analysis via two different methods in quantifying the arch form, and to establish agreement with the fourth-order polynomial equation. This study included 64 sets of digitised maxilla and mandible dental casts obtained from a sample of dental arch with normal occlusion. For human evaluation, a convenient sample of orthodontic practitioners ranked the photo images of dental cast from the most tapered to the less tapered (square). In the mathematical analysis, dental arches were interpolated using the fourth-order polynomial equation with millimetric acetate paper and AutoCAD software. Finally, the relations between human evaluation and mathematical objective analyses were evaluated. Human evaluations were found to be generally in agreement, but only at the extremes of tapered and square arch forms; this indicated general human error and observer bias. The two methods used to plot the arch form were comparable. The use of fourth-order polynomial equation may be facilitative in obtaining a smooth curve, which can produce a template for individual arch that represents all potential tooth positions for the dental arch. Copyright © 2018 CEO. Published by Elsevier Masson SAS. All rights reserved.

  19. Soliton propagation in tapered silicon core fibers.

    PubMed

    Peacock, Anna C

    2010-11-01

    Numerical simulations are used to investigate soliton-like propagation in tapered silicon core optical fibers. The simulations are based on a realistic tapered structure with nanoscale core dimensions and a decreasing anomalous dispersion profile to compensate for the effects of linear and nonlinear loss. An intensity misfit parameter is used to establish the optimum taper dimensions that preserve the pulse shape while reducing temporal broadening. Soliton formation from Gaussian input pulses is also observed--further evidence of the potential for tapered silicon fibers to find use in a range of signal processing applications.

  20. Monitoring techniques for the manufacture of tapered optical fibers.

    PubMed

    Mullaney, Kevin; Correia, Ricardo; Staines, Stephen E; James, Stephen W; Tatam, Ralph P

    2015-10-01

    The use of a range of optical techniques to monitor the process of fabricating optical fiber tapers is investigated. Thermal imaging was used to optimize the alignment of the optical system; the transmission spectrum of the fiber was monitored to confirm that the tapers had the required optical properties and the strain induced in the fiber during tapering was monitored using in-line optical fiber Bragg gratings. Tapers were fabricated with diameters down to 5 μm and with waist lengths of 20 mm using single-mode SMF-28 fiber.

  1. Mode conversion in a tapered fiber via a whispering gallery mode resonator and its application as add/drop filter.

    PubMed

    Huang, Ligang; Wang, Jie; Peng, Weihua; Zhang, Wending; Bo, Fang; Yu, Xuanyi; Gao, Feng; Chang, Pengfa; Song, Xiaobo; Zhang, Guoquan; Xu, Jingjun

    2016-02-01

    Based on the conversion between the fundamental mode (LP01) and the higher-order mode (LP11) in a tapered fiber via a whispering gallery mode resonator, an add/drop filter was proposed and demonstrated experimentally, in which the resonator only interacted with one tapered fiber, rather than two tapered fibers as in conventional configurations. The filter gains advantages of easy alignment and low scattering loss over the other filters based on tapered fiber and resonator, and will be useful in application.

  2. The fabrication of a tapered fiber connector and its coupling efficiency

    NASA Astrophysics Data System (ADS)

    Qinggui, Hu; Chengzhong, Li

    2017-11-01

    In order to reduce the adverse influence of transversal displacement of the optical fiber connector, we propose the directional tapered communication fiber connector, in which the fiber head is tapered according to the signal transmission direction to improve efficiency. We used a flame-brush technique to produce the tapered fiber successfully. In the next step, two experiments in different environments were performed; one in a static environment and the other in a vibration environment. The first experiment shows that the efficiency of the tapered connector is higher than that of the common connector in the same transversal displacement. The second experiment shows that the efficiency of the tapered connector is higher than that of the common connector in the same frequency and amplitude.

  3. Multiple-taper spectral analysis: A stand-alone C-subroutine

    NASA Astrophysics Data System (ADS)

    Lees, Jonathan M.; Park, Jeffrey

    1995-03-01

    A simple set of subroutines in ANSI-C are presented for multiple taper spectrum estimation. The multitaper approach provides an optimal spectrum estimate by minimizing spectral leakage while reducing the variance of the estimate by averaging orthogonal eigenspectrum estimates. The orthogonal tapers are Slepian nπ prolate functions used as tapers on the windowed time series. Because the taper functions are orthogonal, combining them to achieve an average spectrum does not introduce spurious correlations as standard smoothed single-taper estimates do. Furthermore, estimates of the degrees of freedom and F-test values at each frequency provide diagnostics for determining levels of confidence in narrow band (single frequency) periodicities. The program provided is portable and has been tested on both Unix and Macintosh systems.

  4. High power long pulse microwave generation from a metamaterial structure with reverse symmetry

    NASA Astrophysics Data System (ADS)

    Lu, Xueying; Stephens, Jacob C.; Mastovsky, Ivan; Shapiro, Michael A.; Temkin, Richard J.

    2018-02-01

    Experimental operation of a high power microwave source with a metamaterial (MTM) structure is reported at power levels to 2.9 MW at 2.4 GHz in full 1 μs pulses. The MTM structure is formed by a waveguide that is below cutoff for TM modes. The waveguide is loaded by two axial copper plates machined with complementary split ring resonators, allowing two backward wave modes to propagate in the S-Band. A pulsed electron beam of up to 490 kV, 84 A travels down the center of the waveguide, midway between the plates. The electron beam is generated by a Pierce gun and is focused by a lens into a solenoidal magnetic field. The MTM plates are mechanically identical but are placed in the waveguide with reverse symmetry. Theory indicates that both Cherenkov and Cherenkov-cyclotron beam-wave interactions can occur. High power microwave generation was studied by varying the operating parameters over a wide range, including the electron beam voltage, the lens magnetic field, and the solenoidal field. Frequency tuning with a magnetic field and beam voltage was studied to discriminate between operation in the Cherenkov mode and the Cherenkov-cyclotron mode. Both modes were observed, but pulses above 1 MW of output power were only seen in the Cherenkov-cyclotron mode. A pair of steering coils was installed prior to the interaction space to initiate the cyclotron motion of the electron beam and thus encourage the Cherenkov-cyclotron high power mode. This successfully increased the output power from 2.5 MW to 2.9 MW (450 kV, 74 A, 9% efficiency).

  5. Factors associated with independent pharmacy owners' satisfaction with Medicare Part D contracts.

    PubMed

    Zhang, Su; Doucette, William R; Urmie, Julie M; Xie, Yang; Brooks, John M

    2010-06-01

    As Medicare Part D contracts apply pressure on the profitability of independent pharmacies, there is concern about their owners' willingness to sign such contracts. Identifying factors affecting independent pharmacy owners' satisfaction with Medicare Part D contracts could inform policy makers in managing Medicare Part D. (1) To identify influences on independent pharmacy owners' satisfaction with Medicare Part D contracts and (2) to characterize comments made by independent pharmacy owners about Medicare Part D. This cross-sectional study used a mail survey of independent pharmacy owners in 15 states comprising 6 Medicare regions to collect information on their most- and least-favorable Medicare Part D contracts, including satisfaction, contract management activities, market position, pharmacy operation, and specific payment levels on brand and generic drugs. Of the 1649 surveys mailed, 296 surveys were analyzed. The regression models for satisfaction with both the least and the most-favorable Part D contracts were significant (P<0.05). A different set of significant influences on satisfaction was identified for each regression model. For the most-favorable contract, influences were contending and equity. For the least-favorable contract, influences were negotiation, equity, generic rate bonus, and medication therapy management (MTM) payment. About one-third of the survey respondents made at least 1 comment. The most frequent themes in the comments were that Medicare Part D reimbursement rate is too low (28%) and that contracts are offered without negotiation in a "take it or leave it" manner (20%). Equity, contending, negotiation, generic rate bonus, and MTM payments were identified as the influences of independent pharmacy owners' satisfaction toward Medicare Part D contracts. Generic rate bonus and MTM payment provide additional financial incentives to less financially favorable contracts and, in turn, contribute to independent pharmacy owner's satisfaction toward these contracts. Copyright 2010 Elsevier Inc. All rights reserved.

  6. Do NiTi instruments show defects before separation? Defects caused by torsional fatigue in hand and rotary nickel-titanium (NiTi) instruments which lead to failure during clinical use.

    PubMed

    Chakka, N V Murali Krishna; Ratnakar, P; Das, Sanjib; Bagchi, Anandamy; Sudhir, Sudhir; Anumula, Lavanya

    2012-11-01

    Visual and microscopic evaluation of defects caused by torsional fatigue in hand and rotary nickel titanium (NiTi) instruments. Ninety-six NiTi greater taper instruments which were routinely used for root canal treatment only in anterior teeth were selected for the study. The files taken include ProTaper for hand use, ProTaper Rotary files and Endowave rotary files. After every use, the files were observed visually and microscopically (Stereomicroscope at 10×) to evaluate the defects caused by torsional fatigue. Scoring was given according to a new classification formulated which gives an indication of the severity of the defect or damage. Data was statistically analyzed using KruskallWallis and Mann-Whitney U test. Number of files showing defects were more under stereomicroscope than visual examination. But, the difference in the evaluation methods was not statistically significant. The different types of defects observed were bent instrument, straightening/stretching of twist contour and partial reverse twisting. Endowave files showed maximum number of defects followed by ProTaper for hand use and least in ProTaper Rotary. Visible defects due to torsional fatigue do occur in NiTi instruments after clinical use. Both visual and microscopic examinations were efficient in detecting defects caused due to torsional fatigue. This study emphasizes that all files should be observed for any visible defects before and after every instrumentation cycle to minimize the risk of instrument separation and failure of endodontic therapy.

  7. High-power fused assemblies enabled by advances in fiber-processing technologies

    NASA Astrophysics Data System (ADS)

    Wiley, Robert; Clark, Brett

    2011-02-01

    The power handling capabilities of fiber lasers are limited by the technologies available to fabricate and assemble the key optical system components. Previous tools for the assembly, tapering, and fusion of fiber laser elements have had drawbacks with regard to temperature range, alignment capability, assembly flexibility and surface contamination. To provide expanded capabilities for fiber laser assembly, a wide-area electrical plasma heat source was used in conjunction with an optimized image analysis method and a flexible alignment system, integrated according to mechatronic principles. High-resolution imaging and vision-based measurement provided feedback to adjust assembly, fusion, and tapering process parameters. The system was used to perform assembly steps including dissimilar-fiber splicing, tapering, bundling, capillary bundling, and fusion of fibers to bulk optic devices up to several mm in diameter. A wide range of fiber types and diameters were tested, including extremely large diameters and photonic crystal fibers. The assemblies were evaluated for conformation to optical and mechanical design criteria, such as taper geometry and splice loss. The completed assemblies met the performance targets and exhibited reduced surface contamination compared to assemblies prepared on previously existing equipment. The imaging system and image analysis algorithms provided in situ fiber geometry measurement data that agreed well with external measurement. The ability to adjust operating parameters dynamically based on imaging was shown to provide substantial performance benefits, particularly in the tapering of fibers and bundles. The integrated design approach was shown to provide sufficient flexibility to perform all required operations with a minimum of reconfiguration.

  8. Examination of tapered plastic multimode fiber-based sensor performance with silver coating for different concentrations of calcium hypochlorite by soft computing methodologies--a comparative study.

    PubMed

    Zakaria, Rozalina; Sheng, Ong Yong; Wern, Kam; Shamshirband, Shahaboddin; Wahab, Ainuddin Wahid Abdul; Petković, Dalibor; Saboohi, Hadi

    2014-05-01

    A soft methodology study has been applied on tapered plastic multimode sensors. This study basically used tapered plastic multimode fiber [polymethyl methacrylate (PMMA)] optics as a sensor. The tapered PMMA fiber was fabricated using an etching method involving deionized water and acetone to achieve a waist diameter and length of 0.45 and 10 mm, respectively. In addition, a tapered PMMA probe, which was coated by silver film, was fabricated and demonstrated using a calcium hypochlorite (G70) solution. The working mechanism of such a device is based on the observation increment in the transmission of the sensor that is immersed in solutions at high concentrations. As the concentration was varied from 0 to 6 ppm, the output voltage of the sensor increased linearly. The silver film coating increased the sensitivity of the proposed sensor because of the effective cladding refractive index, which increases with the coating and thus allows more light to be transmitted from the tapered fiber. In this study, the polynomial and radial basis function (RBF) were applied as the kernel function of the support vector regression (SVR) to estimate and predict the output voltage response of the sensors with and without silver film according to experimental tests. Instead of minimizing the observed training error, SVR_poly and SVR_rbf were used in an attempt to minimize the generalization error bound so as to achieve generalized performance. An adaptive neuro-fuzzy interference system (ANFIS) approach was also investigated for comparison. The experimental results showed that improvements in the predictive accuracy and capacity for generalization can be achieved by the SVR_poly approach in comparison to the SVR_rbf methodology. The same testing errors were found for the SVR_poly approach and the ANFIS approach.

  9. Effect of implant macro-design on primary stability: A prospective clinical study

    PubMed Central

    Lozano-Carrascal, Naroa; Salomó-Coll, Oscar; Gilabert-Cerdà, Marta; Farré-Pagés, Nuria; Hernández-Alfaro, Federico

    2016-01-01

    Background Implant restorations have become a high predictable treatment option. Several caracteristics such as surgical technique and implant design can influence the treatment outcomes. The aim of the present study was to evaluate the influence of implant macro-design on primary stability measured with resonance frequency analysis (RFA) and insertion torque (IT). Material and Methods A total of 47 implants divided in two groups: Test group (TI): 22 Tapered MIS® Seven implants; Control group (CI): 25 cylindrical Astra® Osseospeed implants. All implants were inserted following the manufacturers’ standard protocols. Implant primary stability was measured at the moment of implant placement by registering insertion torque values (ITv) and ISQ values by means of Osstell™ Mentor (ISQv) (Integration Diagnostic Ltd., Goteborg, Sweden). Results In the mandible, mean ISQv for tapered implants (TI) was 71.67±5.16 and for cylindrical implants (CI) 57.15±4.83 (p=0.01). Mean insertion torque was 46.67±6.85 Ncm for TI and 35.77±6.72 Ncm for CI (p=0.01). In the maxilla, mean ISQ was 67.2±4.42 for tapered implants and 49.17±15.30 for cylindrical implants (p=0.01). Mean insertion torque for TI was 41.5±6.26 Ncm and for CI 39.17±6.34 Ncm (p>0.05). For tapered implants, no correlation could be found between implant diameter and primary stability. But for cylindrical implants there was a statistically significant correlation between implant diameter and primary stability: ITv (p=0.03); ISQv (p=0.04). Conclusions Within the limits of the present study, tapered shaped implants achieve higher primary stability measured through ISQ and insertion torque values. Moreover, for cylindrical implants positive correlation has been established between implant diameter and primary stability. Key words:Primary stability, tapered, cylindrical, conical, implant macro-design. PMID:26827067

  10. Stable C-band fiber laser with switchable multi-wavelength output using coupled microfiber Mach-Zehnder interferometer

    NASA Astrophysics Data System (ADS)

    Ahmad, H.; Jasim, A. A.

    2017-07-01

    A compact coupled microfiber Mach-Zehnder interferometer (CM-MZI) is proposed and experimentally demonstrated for C-band region multi-wavelength tuning and switching in a fiber laser. The CM-MZI is fabricated using a 9 μm single tapered silica optical microfiber fabricated by flame-drawing technique and exploits multi-mode interference to produce spatial mode beating and suppress mode competition of the homogeneous gain medium. The output wavelength spacing is immune to changes in the external environment, but can be changed from 1.5 nm to 1.4 nm by slightly modifying the path-length difference of the CM-MZI. The proposed laser is capable of generating single, dual, triple, quintuple, and sextuple stabilize wavelengths outputs over a range of more than 32 nm using polarization rotation (PR) and macro-bending. The lasers having a 3 dB line-width of less than ∼30 pm and peak-to-floor of about 55 dB at a pump power of 38 mW.

  11. P09.62 Towards individualized survival prediction in glioblastoma patients using machine learning methods

    PubMed Central

    Vera, L.; Pérez-Beteta, J.; Molina, D.; Borrás, J. M.; Benavides, M.; Barcia, J. A.; Velásquez, C.; Albillo, D.; Lara, P.; Pérez-García, V. M.

    2017-01-01

    Abstract Introduction: Machine learning methods are integrated in clinical research studies due to their strong capability to discover parameters having a high information content and their predictive combined potential. Several studies have been developed using glioblastoma patient’s imaging data. Many of them have focused on including large numbers of variables, mostly two-dimensional textural features and/or genomic data, regardless of their meaning or potential clinical relevance. Materials and methods: 193 glioblastoma patients were included in the study. Preoperative 3D magnetic resonance images were collected and semi-automatically segmented using an in-house software. After segmentation, a database of 90 parameters including geometrical and textural image-based measures together with patients’ clinical data (including age, survival, type of treatment, etc.) was constructed. The criterion for including variables in the study was that they had either shown individual impact on survival in single or multivariate analyses or have a precise clinical or geometrical meaning. These variables were used to perform several machine learning experiments. In a first set of computational cross-validation experiments based on regression trees, those attributes showing the highest information measures were extracted. In the second phase, more sophisticated learning methods were employed in order to validate the potential of the previous variables predicting survival. Concretely support vector machines, neural networks and sparse grid methods were used. Results: Variables showing high information measure in the first phase provided the best prediction results in the second phase. Specifically, patient age, Stupp regimen and a geometrical measure related with the irregularity of contrast-enhancing areas were the variables showing the highest information measure in the first stage. For the second phase, the combinations of patient age and Stupp regimen together with one tumor geometrical measure and one tumor heterogeneity feature reached the best quality prediction. Conclusions: Advanced machine learning methods identified the parameters with the highest information measure and survival predictive potential. The uninformed machine learning methods identified a novel feature measure with direct impact on survival. Used in combination with other previously known variables multi-indexes can be defined that can help in tumor characterization and prognosis prediction. Recent advances on the definition of those multi-indexes will be reported in the conference. Funding: James S. Mc. Donnell Foundation (USA) 21st Century Science Initiative in Mathematical and Complex Systems Approaches for Brain Cancer [Collaborative award 220020450 and planning grant 220020420], MINECO/FEDER [MTM2015-71200-R], JCCM [PEII-2014-031-P].

  12. Comparative evaluation of rotary ProTaper, Profile, and conventional stepback technique on reduction in Enterococcus faecalis colony-forming units and vertical root fracture resistance of root canals.

    PubMed

    Singla, Mamta; Aggarwal, Vivek; Logani, Ajay; Shah, Naseem

    2010-03-01

    The purpose of this in vitro study was to evaluate the effect of various root canal instrumentation techniques with different instrument tapers on cleaning efficacy and resultant vertical root fracture (VRF) strength of the roots. Fifty human mandibular first premolar roots were enlarged to ISO size 20, inoculated with Enterococcus faecalis [ATCC2912] for 72 hours and divided into 5 groups: group I: prepared with .02 taper hand instruments ISO size 40; group II: Profile .04 taper size 40; group III: Profile .06 taper size 40; group IV: ProTaper size F4; and group V (control group) further divided into: Va: with bacterial inoculation and no mechanical instrumentation; and Group Vb: neither bacterial inoculation nor mechanical instrumentation. Cleaning efficacy was evaluated in terms of reduction of colony forming units (CFUs). The VRF strength was evaluated using D11 spreader as wedge in an Instron testing machine. Root canals instrumented with ProTaper and 6% Profile instruments showed maximum reduction in CFUs, with statistically insignificant difference between them. The VRF resistance decreased in all instrumented groups. The difference of VRF between 2% and 4% taper Profile groups was statistically insignificant (P = .195). One-way analysis of variance showed that canals instrumented with ProTaper F4 showed maximum reduction in VRF resistance compared with control uninstrumented group. Profile 6% taper instruments offer the advantage of maximum debridement without significant reduction in root fracture resistance. Copyright 2010 Mosby, Inc. All rights reserved.

  13. Interventional MRI: tapering improves the distal sensitivity of the loopless antenna.

    PubMed

    Qian, Di; El-Sharkawy, AbdEl-Monem M; Atalar, Ergin; Bottomley, Paul A

    2010-03-01

    The "loopless antenna" is an interventional MRI detector consisting of a tuned coaxial cable and an extended inner conductor or "whip". A limitation is the poor sensitivity afforded at, and immediately proximal to, its distal end, which is exacerbated by the extended whip length when the whip is uniformly insulated. It is shown here that tapered insulation dramatically improves the distal sensitivity of the loopless antenna by pushing the current sensitivity toward the tip. The absolute signal-to-noise ratio is numerically computed by the electromagnetic method-of-moments for three resonant 3-T antennae with no insulation, uniform insulation, and with linearly tapered insulation. The analysis shows that tapered insulation provides an approximately 400% increase in signal-to-noise ratio in trans-axial planes 1 cm from the tip and a 16-fold increase in the sensitive area as compared to an equivalent, uniformly insulated antenna. These findings are directly confirmed by phantom experiments and by MRI of an aorta specimen. The results demonstrate that numerical electromagnetic signal-to-noise ratio analysis can accurately predict the loopless detector's signal-to-noise ratio and play a central role in optimizing its design. The manifold improvement in distal signal-to-noise ratio afforded by redistributing the insulation should improve the loopless antenna's utility for interventional MRI. (c) 2010 Wiley-Liss, Inc.

  14. Apical extrusion of debris in four different endodontic instrumentation systems: A meta-analysis

    PubMed Central

    Western, J. Sylvia; Dicksit, Daniel Devaprakash

    2017-01-01

    Background: All endodontic instrumentation systems tested so far, promote apical extrusion of debris, which is one of the main causes of postoperative pain, flare ups, and delayed healing. Objectives: Of this meta-analysis was to collect and analyze in vitro studies quantifying apically extruded debris while using Hand ProTaper (manual), ProTaper Universal (rotary), Wave One (reciprocating), and self-adjusting file (SAF; vibratory) endodontic instrumentation systems and to determine methods which produced lesser extrusion of debris apically. Methodology: An extensive electronic database search was done in PubMed, Scopus, Cochrane, LILACS, and Google Scholar from inception until February 2016 using the key terms “Apical Debris Extrusion, extruded material, and manual/rotary/reciprocating/SAF systems.” A systematic search strategy was followed to extract 12 potential articles from a total of 1352 articles. The overall effect size was calculated from the raw mean difference of weight of apically extruded debris. Results: Statistically significant difference was seen in the following comparisons: SAF < Wave One, SAF < Rotary ProTaper. Conclusions: Apical extrusion of debris was invariably present in all the instrumentation systems analyzed. SAF system seemed to be periapical tissue friendly as it caused reduced apical extrusion compared to Rotary ProTaper and Wave One. PMID:28761250

  15. The effect of screw taper on interference fit during load to failure at the soft tissue/bone interface.

    PubMed

    Mann, Charles J; Costi, John J; Stanley, Richard M; Dobson, Peter J

    2005-10-01

    The effect of screw geometry on the pullout strength of an anterior cruciate ligament reconstruction is well documented. The effect of a truly tapered screw has not been previously investigated. Thirty bovine knees in right and left knee pairs were collected. Superficial digital flexors from the hind legs of sheep were harvested to form a quadruple tendon graft. For each knee pair, one tendon graft was fixed using a tapered screw (n=15) and the other with a non-tapered screw (n=15). Interference screws were manufactured from stainless steel, and apart from the tapered or non-tapered profile were identical. The screws were inserted into a tibial tunnel already containing the tendon graft. The interference fit was tested by extensile load to failure tests. The insertion torque of the screws and first sign of load to failure (by pullout) of the interference fit were recorded. Results were analysed using paired t-tests. The results indicated that tapered screws have significantly higher resistance to interference failure (p=0.007) and insertion torque (p<0.001) than non-tapered screws. The improved biomechanical performance of tapered screws demonstrated in this study may translate into superior clinical results, particularly at the tibial attachment of hamstring anterior cruciate ligament reconstruction, and also of hamstring fixation to the medial femoral condyle for patella instability.

  16. Comparison for 1030nm DBR-tapered diode lasers with 10W central lobe output power and different grating layouts for wavelength stabilization and lateral spatial mode filtering

    NASA Astrophysics Data System (ADS)

    Müller, André; Zink, Christof; Fricke, Jörg; Bugge, Frank; Erbert, Götz; Sumpf, Bernd; Tränkle, Günther

    2018-02-01

    1030 nm DBR tapered diode lasers with different lateral layouts are presented. The layout comparison includes lasers with straight waveguide and grating, tapered waveguide and straight grating, and straight waveguide and tapered grating. The lasers provide narrowband emission and optical output powers up to 15 W. The highest diffraction-limited central lobe output power of 10.5 W is obtained for lasers with tapered gratings only. Small variations in central lobe output power with RW injection current density also indicate the robustness of that layout. For lasers with tapered waveguides, high RW injection current densities up to 150 A/mm2 have to be applied in order to obtain high central lobe output powers. Lasers with straight waveguide and grating operate best at low RW injection current densities, 50 A/mm2 applied in this study. Using the layout optimizations discussed in this study may help to increase the application potential of DBR tapered diode lasers.

  17. Hand-operated and rotary ProTaper instruments: a comparison of working time and number of rotations in simulated root canals.

    PubMed

    Pasqualini, Damiano; Scotti, Nicola; Tamagnone, Lorenzo; Ellena, Federica; Berutti, Elio

    2008-03-01

    The aim of this study was to compare the effective shaping time and number of rotations required by an endodontist working with hand and rotary ProTaper instruments to completely shape simulated root canals. Eighty Endo Training Blocks (curved canal shape) were used. Manual preflaring was performed with K-Flexofiles #08-10-12-15-17 and #20 Nitiflex at a working length of 18 mm. Specimens were then randomly assigned to 2 different groups (n = 40); group 1 was shaped by using hand ProTaper and group 2 with ProTaper rotary. The number of rotations made in the canal and the effective time required to achieve complete canal shaping were recorded for each instrument. Differences between groups were analyzed with the nonparametric Mann-Whitney U test (P < .05). Hand ProTaper required significantly fewer rotations (P < .001) than rotary ProTaper, whereas the effective working time to fully shape the simulated canal was significantly higher (P < .001) with hand ProTaper.

  18. 76 FR 37372 - Notice of Proposed Withdrawal Extension and Notification of a Public Meeting; Montana

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-27

    ... DEPARTMENT OF THE INTERIOR Bureau of Land Management [61510-8451-0000; MTM 80092] Notice of Proposed Withdrawal Extension and Notification of a Public Meeting; Montana AGENCY: Bureau of Land...; 8:45 am] BILLING CODE 4310-55-P ...

  19. Oriented clay nanopaper from biobased components--mechanisms for superior fire protection properties.

    PubMed

    Carosio, F; Kochumalayil, J; Cuttica, F; Camino, G; Berglund, L

    2015-03-18

    The toxicity of the most efficient fire retardant additives is a major problem for polymeric materials. Cellulose nanofiber (CNF)/clay nanocomposites, with unique brick-and-mortar structure and prepared by simple filtration, are characterized from the morphological point of view by scanning electron microscopy and X-ray diffraction. These nanocomposites have superior fire protection properties to other clay nanocomposites and fiber composites. The corresponding mechanisms are evaluated in terms of flammability (reaction to a flame) and cone calorimetry (exposure to heat flux). These two tests provide a wide spectrum characterization of fire protection properties in CNF/montmorrilonite (MTM) materials. The morphology of the collected residues after flammability testing is investigated. In addition, thermal and thermo-oxidative stability are evaluated by thermogravimetric analyses performed in inert (nitrogen) and oxidative (air) atmospheres. Physical and chemical mechanisms are identified and related to the unique nanostructure and its low thermal conductivity, high gas barrier properties and CNF/MTM interactions for char formation.

  20. Broadbanding of circularly polarized patch antenna by waveguided magneto-dielectric metamaterial

    NASA Astrophysics Data System (ADS)

    Yang, Xin Mi; Wen, Juan; Liu, Chang Rong; Liu, Xue Guan; Cui, Tie Jun

    2015-12-01

    Design of bandwidth-enhanced circularly polarized (CP) patch antenna using artificial magneto-dielectric substrate was investigated. The artificial magneto-dielectric material adopted here takes the form of waveguided metamaterial (WG-MTM). In particular, the embedded meander line (EML) structure was employed as the building element of the WG-MTM. As verified by the retrieved effective medium parameters, the EML-based waveguided magneto-dielectric metamaterial (WG-MDM) exhibits two-dimensionally isotropic magneto-dielectric property with respect to TEM wave excitations applied in two orthogonal directions. A CP patch antenna loaded with the EML-based WG-MDM (WG-MDM antenna) has been proposed and its design procedure is described in detail. Simulation results show that the impedance and axial ratio bandwidths of the WG-MDM antenna have increased by 125% and 133%, respectively, compared with those obtained with pure dielectric substrate offering the same patch size. The design of the novel WG-MDM antenna was also validated by measurement results, which show good agreement with their simulated counterparts.

  1. Ultra-low-loss optical fiber nanotapers.

    PubMed

    Brambilla, Gilberto; Finazzi, Vittoria; Richardson, David

    2004-05-17

    Optical fiber tapers with a waist size larger than 1microm are commonplace in telecommunications and sensor applications. However the fabrication of low-loss optical fiber tapers with subwavelength diameters was previously thought to be impractical due to difficulties associated with control of the surface roughness and diameter uniformity. In this paper we show that very-long ultra-low-loss tapers can in fact be produced using a conventional fiber taper rig incorporating a simple burner configuration. For single-mode operation, the optical losses we achieve at 1.55microm are one order of magnitude lower than losses previously reported in the literature for tapers of a similar size. SEM images confirm excellent taper uniformity. We believe that these low-loss structures should pave the way to a whole range of fiber nanodevices.

  2. Reduced acoustic noise in diffusion tensor imaging on a compact MRI system.

    PubMed

    Tan, Ek T; Hardy, Christopher J; Shu, Yunhong; In, Myung-Ho; Guidon, Arnaud; Huston, John; Bernstein, Matt A; K F Foo, Thomas

    2018-06-01

    To investigate the feasibility of substantially reducing acoustic noise while performing diffusion tensor imaging (DTI) on a compact 3T (C3T) MRI scanner equipped with a 42-cm inner-diameter asymmetric gradient. A-weighted acoustic measurements were made using 10 mT/m-amplitude sinusoidal waveforms, corresponding to echo-planar imaging (EPI) echo spacing of 0.25 to 5.0 ms, on a conventional, whole-body 3T MRI and on the C3T. Acoustic measurements of DTI with trapezoidal EPI waveforms were then made at peak gradient performance on the C3T (80 mT/m amplitude, 700 T/m/s slew rate) and at derated performance (33 mT/m, 10 to 50 T/m/s) for acoustic noise reduction. DTI was acquired in two different phantoms and in seven human subjects, with and without gradient-derating corresponding to multi- and single-shot acquisitions, respectively. Sinusoidal waveforms on the C3T were quieter by 8.5 to 15.6 A-weighted decibels (dBA) on average as compared to the whole-body MRI. The derated multishot DTI acquisition noise level was only 8.7 dBA (at 13 T/m/s slew rate) above ambient, and was quieter than non-derated, single-shot DTI by 22.3 dBA; however, the scan time was almost quadrupled. Although derating resulted in negligible diffusivity differences in the phantoms, small biases in diffusivity measurements were observed in human subjects (apparent diffusion coefficient = +9.3 ± 8.8%, fractional anisotropy = +3.2 ± 11.2%, radial diffusivity = +9.4 ± 16.8%, parallel diffusivity = +10.3 ± 8.4%). The feasibility of achieving reduced acoustic noise levels with whole-brain DTI on the C3T MRI was demonstrated. Magn Reson Med 79:2902-2911, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  3. Multi-year climate variability in the Southwestern United States within a context of a dynamically downscaled twentieth century reanalysis

    NASA Astrophysics Data System (ADS)

    Carrillo, Carlos M.; Castro, Christopher L.; Chang, Hsin-I.; Luong, Thang M.

    2017-12-01

    This investigation evaluates whether there is coherency in warm and cool season precipitation at the low-frequency scale that may be responsible for multi-year droughts in the US Southwest. This low-frequency climate variability at the decadal scale and longer is studied within the context of a twentieth-century reanalysis (20CR) and its dynamically-downscaled version (DD-20CR). A spectral domain matrix methods technique (Multiple-Taper-Method Singular Value Decomposition) is applied to these datasets to identify statistically significant spatiotemporal precipitation patterns for the cool (November-April) and warm (July-August) seasons. The low-frequency variability in the 20CR is evaluated by exploring global to continental-scale spatiotemporal variability in moisture flux convergence (MFC) to the occurrence of multiyear droughts and pluvials in Central America, as this region has a demonstrated anti-phase relationship in low-frequency climate variability with northern Mexico and the southwestern US By using the MFC in lieu of precipitation, this study reveals that the 20CR is able to resolve well the low-frequency, multiyear climate variability. In the context of the DD-20CR, multiyear droughts and pluvials in the southwestern US (in the early twentieth century) are significantly related to this low-frequency climate variability. The precipitation anomalies at these low-frequency timescales are in phase between the cool and warm seasons, consistent with the concept of dual-season drought as has been suggested in tree ring studies.

  4. Dwarf mistletoe does not increase trunk taper in released red firs in California

    Treesearch

    Robert F. Scharpf

    1977-01-01

    Dwarf mistletoe had no noticeable effect on trunk taper of young, dominant and codominant red firs 4 to 22 inches (10.2 to 55.9 cm) d.b.h. Also, taper was not influenced by live crown ratio of infected and uninfected trees. Trees less than 7 inches d.b.h. had significantly more taper than larger trees, irrespective of dwarf mistletoe.

  5. Comparison of the fracture resistance of dental implants with different abutment taper angles.

    PubMed

    Wang, Kun; Geng, Jianping; Jones, David; Xu, Wei

    2016-06-01

    To investigate the effects of abutment taper angles on the fracture strength of dental implants with TIS (taper integrated screwed-in) connection. Thirty prototype cylindrical titanium alloy 5.0mm-diameter dental implants with different TIS-connection designs were divided into six groups and tested for their fracture strength, using a universal testing machine. These groups consisted of combinations of 3.5 and 4.0 mm abutment diameter, each with taper angles of 6°, 8° or 10°. 3-Dimensional finite element analysis (FEA) was also used to analyze stress states at implant-abutment connection areas. In general, the mechanical tests found an increasing trend of implant fracture forces as the taper angle enlarged. When the abutment diameter was 3.5 mm, the mean fracture forces for 8° and 10° taper groups were 1638.9 N ± 20.3 and 1577.1 N ± 103.2, respectively, both larger than that for the 6° taper group of 1475.0 N ± 24.4, with the largest increasing rate of 11.1%. Furthermore, the difference between 8° and 6° taper groups was significant, based on Tamhane's multiple comparison test (P<0.05). In 4.0 mm-diameter abutment groups, as the taper angle was enlarged from 6° to 8° and 10°, the mean fracture value was increased from 1066.7 N ± 56.1 to 1241.4 N ± 6.4 and 1419.3 N ± 20.0, with the largest increasing rate of 33.1%, and the differences among the three groups were significant (P<0.05). The FEA results showed that stress values varied in implants with different abutment taper angles and supported the findings of the static tests. In conclusion, increases of the abutment taper angle could significantly increase implant fracture resistance in most cases established in the study, which is due to the increased implant wall thickness in the connection part resulting from the taper angle enlargement. The increasing effects were notable when a thin implant wall was present to accommodate wide abutments. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Systematic cavity design approach for a multi-frequency gyrotron for DEMO and study of its RF behavior

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalaria, P. C., E-mail: parth.kalaria@partner.kit.edu; Avramidis, K. A.; Franck, J.

    High frequency (>230 GHz) megawatt-class gyrotrons are planned as RF sources for electron cyclotron resonance heating and current drive in DEMOnstration fusion power plants (DEMOs). In this paper, for the first time, a feasibility study of a 236 GHz DEMO gyrotron is presented by considering all relevant design goals and the possible technical limitations. A mode-selection procedure is proposed in order to satisfy the multi-frequency and frequency-step tunability requirements. An effective systematic design approach for the optimal design of a gradually tapered cavity is presented. The RF-behavior of the proposed cavity is verified rigorously, supporting 920 kW of stable output power withmore » an interaction efficiency of 36% including the considerations of realistic beam parameters.« less

  7. Functional significance of the taper of vertebrate cone photoreceptors

    PubMed Central

    Hárosi, Ferenc I.

    2012-01-01

    Vertebrate photoreceptors are commonly distinguished based on the shape of their outer segments: those of cones taper, whereas the ones from rods do not. The functional advantages of cone taper, a common occurrence in vertebrate retinas, remain elusive. In this study, we investigate this topic using theoretical analyses aimed at revealing structure–function relationships in photoreceptors. Geometrical optics combined with spectrophotometric and morphological data are used to support the analyses and to test predictions. Three functions are considered for correlations between taper and functionality. The first function proposes that outer segment taper serves to compensate for self-screening of the visual pigment contained within. The second function links outer segment taper to compensation for a signal-to-noise ratio decline along the longitudinal dimension. Both functions are supported by the data: real cones taper more than required for these compensatory roles. The third function relates outer segment taper to the optical properties of the inner compartment whereby the primary determinant is the inner segment’s ability to concentrate light via its ellipsoid. In support of this idea, the rod/cone ratios of primarily diurnal animals are predicted based on a principle of equal light flux gathering between photoreceptors. In addition, ellipsoid concentration factor, a measure of ellipsoid ability to concentrate light onto the outer segment, correlates positively with outer segment taper expressed as a ratio of characteristic lengths, where critical taper is the yardstick. Depending on a light-funneling property and the presence of focusing organelles such as oil droplets, cone outer segments can be reduced in size to various degrees. We conclude that outer segment taper is but one component of a miniaturization process that reduces metabolic costs while improving signal detection. Compromise solutions in the various retinas and retinal regions occur between ellipsoid size and acuity, on the one hand, and faster response time and reduced light sensitivity, on the other. PMID:22250013

  8. Cyclic fatigue resistance of two nickel-titanium rotary instruments in interrupted rotation.

    PubMed

    Pedullà, E; Lizio, A; Scibilia, M; Grande, N M; Plotino, G; Boninelli, S; Rapisarda, E; Lo Giudice, G

    2017-02-01

    To investigate the influence of interrupted rotation on cyclic fatigue of two nickel-titanium rotary instruments. Cyclic fatigue of 300 new ProTaper Next size X1; X2 and Mtwo size 10, .04 taper; size 15, .05 taper; size 20, .06 taper and size 25, .06 taper instruments was tested in continuous or interrupted rotation. Fifty files of the same brand and size were randomly assigned to five groups (n = 10). Group 1 instruments were tested in continuous rotation; groups 2 and 3 in paused rotation for 1 s every 10 or 20 s, respectively; groups 4 and 5 in interrupted rotation for 5 s every 10 or 20 s, respectively. Cyclic fatigue was expressed in time to fracture (TtF) in an artificial canal with 60° angle and 5 mm radius of curvature. The fracture surface was examined with a scanning electron microscope (SEM). Data were evaluated by two-way analysis of variance. Cyclic fatigue of groups 2 and 4 of ProTaper Next X2 and Mtwo size 25, .06 taper was significantly lower than that of group 1 of the same instruments (P < 0.01). ProTaper Next X2 had significantly reduced cyclic fatigue in groups 3 and 5 (P < 0.05). No differences were found by interrupting the rotation for 1 or 5 s in all instruments (P > 0.05). Fatigue of other instruments was not affected by interrupted rotation (P > 0.05). Interrupted rotation reduced cyclic fatigue resistance of ProTaper Next X2 and Mtwo size 25, .06 taper, especially when a higher number of interruptions was performed. © 2016 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  9. Apically extruded debris with three contemporary Ni-Ti instrumentation systems: an ex vivo comparative study.

    PubMed

    Logani, Ajay; Shah, Naseem

    2008-01-01

    To comparatively evaluate the amount of apically extruded debris when ProTaper hand, ProTaper rotary and ProFile systems were used for the instrumentation of root canals. Thirty minimally curved, mature, human mandibular premolars with single canals were randomly divided into three groups of ten teeth each. Each group was instrumented using one of the three instrumentation systems: ProTaper hand, ProTaper rotary and ProFile. Five milliliters of sterile water were used as an irrigant. Debris extruded was collected in preweighed polyethylene vials and the extruded irrigant was evaporated. The weight of the dry extruded debris was established by comparing the pre- and postinstrumentation weight of polyethylene vials for each group. The Kruskal-Wallis nonparametric test and Mann-Whitney U test were applied to determine if significant differences existed among the groups ( P< 0.05). All instruments tested produced a measurable amount of debris. No statistically significant difference was observed between ProTaper hand and ProFile system ( P > 0.05). Although ProTaper rotary extruded a relatively higher amount of debris, no statistically significant difference was observed between this type and the ProTaper hand instruments ( P > 0.05). The ProTaper rotary extruded significantly more amount of debris compared to the ProFile system ( P< 0.05). Within the limitations of this study, it can be concluded that all instruments tested produced apical extrusion of debris. The ProTaper rotary extruded a significantly higher amount of debris than the ProFile.

  10. Stability of tapered and parallel-walled dental implants: A systematic review and meta-analysis.

    PubMed

    Atieh, Momen A; Alsabeeha, Nabeel; Duncan, Warwick J

    2018-05-15

    Clinical trials have suggested that dental implants with a tapered configuration have improved stability at placement, allowing immediate placement and/or loading. The aim of this systematic review and meta-analysis was to evaluate the implant stability of tapered dental implants compared to standard parallel-walled dental implants. Applying the guidelines of Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) statement, randomized controlled trials (RCTs) were searched for in electronic databases and complemented by hand searching. The risk of bias was assessed using the Cochrane Collaboration's Risk of Bias tool and data were analyzed using statistical software. A total of 1199 studies were identified, of which, five trials were included with 336 dental implants in 303 participants. Overall meta-analysis showed that tapered dental implants had higher implant stability values than parallel-walled dental implants at insertion and 8 weeks but the difference was not statistically significant. Tapered dental implants had significantly less marginal bone loss compared to parallel-walled dental implants. No significant differences in implant failure rate were found between tapered and parallel-walled dental implants. There is limited evidence to demonstrate the effectiveness of tapered dental implants in achieving greater implant stability compared to parallel-walled dental implants. Superior short-term results in maintaining peri-implant marginal bone with tapered dental implants are possible. Further properly designed RCTs are required to endorse the supposed advantages of tapered dental implants in immediate loading protocol and other complex clinical scenarios. © 2018 Wiley Periodicals, Inc.

  11. VizieR Online Data Catalog: MV Lyr - bursts and periods (Pavlenko, 1998)

    NASA Astrophysics Data System (ADS)

    Pavlenko, E. P.

    2001-01-01

    The analysis of photometric behavior of the nova-like star MV Lyr in B in the low brightness state in 1995-1996 based on the observations performed at the Crimean Astrophysical Observatory with the MTM-500 television system was presented. (1 data file).

  12. Comparison of Past, Present, and Future Volume Estimation Methods for Tennessee

    Treesearch

    Stanley J. Zarnoch; Alexander Clark; Ray A. Souter

    2003-01-01

    Forest Inventory and Analysis 1999 survey data for Tennessee were used to compare stem-volume estimates obtained using a previous method, the current method, and newly developed taper models that will be used in the future. Compared to the current method, individual tree volumes were consistently underestimated with the previous method, especially for the hardwoods....

  13. Implementation and Clinical Outcomes of an Employer-Sponsored, Pharmacist-Provided Medication Therapy Management Program.

    PubMed

    Theising, Katie M; Fritschle, Traci L; Scholfield, Angelina M; Hicks, Emily L; Schymik, Michelle L

    2015-11-01

    Our objective was to describe the implementation and clinical outcomes of an employer-sponsored, pharmacist-provided medication therapy management (MTM) program for health plan beneficiaries with diabetes mellitus and/or hypertension. We conducted a single-center retrospective medical record review. The setting was a Pharmacy MTM Clinic at a self-insured health system consisting of six hospitals and several ancillary facilities. A total of 161 health plan beneficiaries with diabetes identified during annual wellness screenings for the health plan in 2012 and 225 health plan beneficiaries with diabetes and/or hypertension identified during annual wellness screenings for the health plan in 2013 were referred to the MTM clinic based on specific criteria. In 2012 the health system expanded its existing wellness program by implementing a voluntary diabetes care program for health plan beneficiaries with uncontrolled diabetes (hemoglobin A(1c) [A1C] 7% or higher); a similar program was added for hypertension for the 2013 plan year. All participants' A1C and blood pressure results were tracked from the date of their wellness screening through the end of the plan year. The pharmacists involved had the capability to directly implement drug regimen changes according to hospital protocol or provide recommendations to the physician, as specified by the referring physician. For the 2012-2013 plan year, the mean difference in A1C from baseline to program completion was -0.38% (95% confidence interval [CI] -0.58 to -0.18%, p<0.05). For beneficiaries with a baseline A1C of 7% or higher, the mean difference was -0.69% (95% CI -0.99 to -0.39%, p<0.05). For the 2013-2014 plan year, the mean difference in A1C from baseline to program completion was -0.62% (95% CI -0.81 to -0.44%, p<0.05). In that year, the mean difference in A1C for beneficiaries with A1C 7% or higher was -0.97% (95% CI -1.23 to -0.72%, p<0.05). For those referred for hypertension, a mean difference of -13 mm Hg (95% CI -18.59 to -7.73, p<0.05) from baseline to program completion was seen in systolic blood pressure, and the mean difference in diastolic blood pressure was -7 mm Hg (95% CI -9.92 to -4.04, p<0.05). This study demonstrated that health plan beneficiaries who participated in the employer-sponsored, pharmacist-provided MTM program had significant decreases in A1C and blood pressure. © 2015 Pharmacotherapy Publications, Inc.

  14. A comparison of experimental and theoretical results for leakage, pressure gradients, and rotordynamic coefficients for tapered annular gas seal

    NASA Technical Reports Server (NTRS)

    Elrod, D. A.; Childs, D. W.

    1986-01-01

    A brief review of current annular seal theory and a discussion of the predicted effect on stiffness of tapering the seal stator are presented. An outline of Nelson's analytical-computational method for determining rotordynamic coefficients for annular compressible-flow seals is included. Modifications to increase the maximum rotor speed of an existing air-seal test apparatus at Texas A&M University are described. Experimental results, including leakage, entrance-loss coefficients, pressure distributions, and normalized rotordynamic coefficients, are presented for four convergent-tapered, smooth-rotor, smooth-stator seals. A comparison of the test results shows that an inlet-to-exit clearance ratio of 1.5 to 2.0 provides the maximum direct stiffness, a clearance ratio of 2.5 provides the greatest stability, and a clearance ratio of 1.0 provides the least stability. The experimental results are compared to theoretical results from Nelson's analysis with good agreement. Test results for cross-coupled stiffness show less sensitivity of fluid prerotation than predicted.

  15. Numerical Investigation of Oxygenated and Deoxygenated Blood Flow through a Tapered Stenosed Arteries in Magnetic Field.

    PubMed

    Abdollahzadeh Jamalabadi, M Y; Akbari Bidokhti, Amin Ali; Khak Rah, Hamid; Vaezi, Siavash; Hooshmand, Payam

    2016-01-01

    Current paper is focused on transient modeling of blood flow through a tapered stenosed arteries surrounded a by solenoid under the presence of heat transfer. The oxygenated and deoxygenated blood are considered here by the Newtonian and Non-Newtonian fluid (power law and Carreau-Yasuda) models. The governing equations of bio magnetic fluid flow for an incompressible, laminar, homogeneous, non-Newtonian are solved by finite volume method with SIMPLE algorithm for structured grid. Both magnetization and electric current source terms are well thought-out in momentum and energy equations. The effects of fluid viscosity model, Hartmann number, and magnetic number on wall shear stress, shearing stress at the stenosis throat and maximum temperature of the system are investigated and are optimized. The current study results are in agreement with some of the existing findings in the literature and are useful in thermal and mechanical design of spatially varying magnets to control the drug delivery and biomagnetic fluid flows through tapered arteries.

  16. Stability analysis of a two-stage tapered gyrotron traveling-wave tube amplifier with distributed losses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hung, C. L.; Lian, Y. H.; Cheng, N. H.

    2012-11-15

    The two-stage tapered gyrotron traveling-wave tube (gyro-TWT) amplifier has achieved wide bandwidth in the millimeter wave range. However, possible oscillations in each stage limit this amplifier's operating beam current and thus its output power. To further enhance the amplifier's stability, distributed losses are applied to the interaction circuit of the two-stage tapered gyro-TWT. A self-consistent particle-tracing code is used for analyzing the beam-wave interactions. The stability analysis includes the effects of the wall losses and the length of each stage on the possible oscillations. Simulation results reveal that the distributed-loss method effectively stabilizes all the oscillations in the two stages.more » Under stable operating conditions, the device is predicted to produce a peak power of 60 kW with an efficiency of 29% and a saturated gain of 52 dB in the Ka-band. The 3-dB bandwidth is 5.7 GHz, which is approximately 16% of the center frequency.« less

  17. Whole-organ cell shape analysis reveals the developmental basis of ascidian notochord taper.

    PubMed

    Veeman, Michael T; Smith, William C

    2013-01-15

    Here we use in toto imaging together with computational segmentation and analysis methods to quantify the shape of every cell at multiple stages in the development of a simple organ: the notochord of the ascidian Ciona savignyi. We find that cell shape in the intercalated notochord depends strongly on anterior-posterior (AP) position, with cells in the middle of the notochord consistently wider than cells at the anterior or posterior. This morphological feature of having a tapered notochord is present in many chordates. We find that ascidian notochord taper involves three main mechanisms: Planar Cell Polarity (PCP) pathway-independent sibling cell volume asymmetries that precede notochord cell intercalation; the developmental timing of intercalation, which proceeds from the anterior and posterior towards the middle; and the differential rates of notochord cell narrowing after intercalation. A quantitative model shows how the morphology of an entire developing organ can be controlled by this small set of cellular mechanisms. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Whole-organ cell shape analysis reveals the developmental basis of ascidian notochord taper

    PubMed Central

    Veeman, Michael T.; Smith, William C.

    2012-01-01

    Here we use in toto imaging together with computational segmentation and analysis methods to quantify the shape of every cell at multiple stages in the development of a simple organ: the notochord of the ascidian Ciona savignyi. We find that cell shape in the intercalated notochord depends strongly on anterior-posterior (AP) position, with cells in the middle of the notochord consistently wider than cells at the anterior or posterior. This morphological feature of having a tapered notochord is present in many chordates. We find that ascidian notochord taper involves three main mechanisms: Planar Cell Polarity (PCP) pathway-independent sibling cell volume asymmetries that precede notochord cell intercalation; the developmental timing of intercalation, which proceeds from the anterior and posterior towards the middle; and the differential rates of notochord cell narrowing after intercalation. A quantitative model shows how the morphology of an entire developing organ can be controlled by this small set of cellular mechanisms. PMID:23165294

  19. Efficient system modeling for a small animal PET scanner with tapered DOI detectors.

    PubMed

    Zhang, Mengxi; Zhou, Jian; Yang, Yongfeng; Rodríguez-Villafuerte, Mercedes; Qi, Jinyi

    2016-01-21

    A prototype small animal positron emission tomography (PET) scanner for mouse brain imaging has been developed at UC Davis. The new scanner uses tapered detector arrays with depth of interaction (DOI) measurement. In this paper, we present an efficient system model for the tapered PET scanner using matrix factorization and a virtual scanner geometry. The factored system matrix mainly consists of two components: a sinogram blurring matrix and a geometrical matrix. The geometric matrix is based on a virtual scanner geometry. The sinogram blurring matrix is estimated by matrix factorization. We investigate the performance of different virtual scanner geometries. Both simulation study and real data experiments are performed in the fully 3D mode to study the image quality under different system models. The results indicate that the proposed matrix factorization can maintain image quality while substantially reduce the image reconstruction time and system matrix storage cost. The proposed method can be also applied to other PET scanners with DOI measurement.

  20. Fabrication and application of a non-contact double-tapered optical fiber tweezers.

    PubMed

    Liu, Z L; Liu, Y X; Tang, Y; Zhang, N; Wu, F P; Zhang, B

    2017-09-18

    A double-tapered optical fiber tweezers (DOFTs) was fabricated by a chemical etching called interfacial layer etching. In this method, the second taper angle (STA) of DOFTs can be controlled easily by the interfacial layer etching time. Application of the DOFTs to the optical trapping of the yeast cells was presented. Effects of the STA on the axile trapping efficiency and the trapping position were investigated experimentally and theoretically. The experimental results are good agreement with the theoretical ones. The results demonstrated that the non-contact capture can be realized for the large STA (e.g. 90 deg) and there was an optimal axile trapping efficiency as the STA increasing. In order to obtain a more accurate measurement result of the trapping force, a correction factor to Stokes drag coefficient was introduced. This work provided a way of designing and fabricating an optical fiber tweezers (OFTs) with a high trapping efficient or a non-contact capture.

Top