Maier, I L; Leyhe, J R; Tsogkas, I; Behme, D; Schregel, K; Knauth, M; Schnieder, M; Liman, J; Psychogios, M-N
2018-05-01
One-stop management of mechanical thrombectomy-eligible patients with large-vessel occlusion represents an innovative approach in acute stroke treatment. This approach reduces door-to-reperfusion times by omitting multidetector CT, using flat detector CT as pre-mechanical thrombectomy imaging. The purpose of this study was to compare the diagnostic performance of the latest-generation flat detector CT with multidetector CT. Prospectively derived data from patients with ischemic stroke with large-vessel occlusion and mechanical thrombectomy were analyzed in this monocentric study. All included patients underwent multidetector CT before referral to our comprehensive stroke center and flat detector CT in the angiography suite before mechanical thrombectomy. Diagnosis of early ischemic signs, quantified by the ASPECTS, was compared between modalities using cross tables, the Pearson correlation, and Bland-Altman plots. The predictive value of multidetector CT- and flat detector CT-derived ASPECTS for functional outcome was investigated using area under the receiver operating characteristic curve analysis. Of 25 patients, 24 (96%) had flat detector CT with sufficient diagnostic quality. Median multidetector CT and flat detector CT ASPECTSs were 7 (interquartile range, 5.5-9 and 4.25-8, respectively) with a mean period of 143.6 ± 49.5 minutes between both modalities. The overall sensitivity was 85.1% and specificity was 83.1% for flat detector CT ASPECTS compared with multidetector CT ASPECTS as the reference technique. Multidetector CT and flat detector CT ASPECTS were strongly correlated ( r = 0.849, P < .001) and moderately predicted functional outcome (area under the receiver operating characteristic curve, 0.738; P = .007 and .715; P = .069, respectively). Determination of ASPECTS on flat detector CT is feasible, showing no significant difference compared with multidetector CT ASPECTS and a similar predictive value for functional outcome. Our findings support the use of flat detector CT for emergency stroke imaging before mechanical thrombectomy to reduce door-to-groin time. © 2018 by American Journal of Neuroradiology.
Soukup, Jason W.; Drees, Randi; Koenig, Lisa J.; Snyder, Christopher J.; Hetzel, Scott; Miles, Chanda R.; Schwarz, Tobias
2016-01-01
Summary The objective of this blinded study was to validate the use of cone beam computed tomography (CT) for imaging of the canine maxillary dentoalveolar structures by comparing its diagnostic image quality with that of 64-multidetector row CT. Sagittal slices of a tooth-bearing segment of the maxilla of a commercially purchased dog skull embedded in methyl methacrylate were obtained along a line parallel with the dental arch using a commercial histology diamond saw. The slice of tooth-bearing bone that best depicted the dentoalveolar structures was chosen and photographed. The maxilla segment was imaged with cone beam CT and 64-multidetector row CT. Four blinded evaluators compared the cone beam CT and 64-multidetector row CT images and image quality was scored as it related to the anatomy of dentoalveolar structures. Trabecular bone, enamel, dentin, pulp cavity, periodontal ligament space, and lamina dura were scored. In addition, a score depicting the evaluators overall impression of the image was recorded. Images acquired with cone beam CT were found to be significantly superior in image quality to images acquired with 64-multidetector row CT overall, and in all scored categories. In our study setting, cone beam CT was found to be a valid and clinically superior imaging modality for the canine maxillary dentoalveolar structures when compared to 64-multidetector row CT. PMID:26415384
Soukup, Jason W; Drees, Randi; Koenig, Lisa J; Snyder, Christopher J; Hetzel, Scott; Miles, Chanda R; Schwarz, Tobias
2015-01-01
The objective of this blinded study was to validate the use of cone beam computed tomography (C) for imaging of the canine maxillary dentoalveolar structures by comparing its diagnostic image quality with that of 64-multidetector row CT Sagittal slices of a tooth-bearing segment of the maxilla of a commercially purchased dog skull embedded in methylmethacrylate were obtained along a line parallel with the dental arch using a commercial histology diamond saw. The slice of tooth-bearing bone that best depicted the dentoalveolar structures was chosen and photographed. The maxillary segment was imaged with cone beam CT and 64-multidetector row CT. Four blinded evaluators compared the cone beam CT and 64-multidetector row CT images and image quality was scored as it related to the anatomy of dentoalveolar structures. Trabecular bone, enamel, dentin, pulp cavity, periodontal ligament space, and lamina dura were scored In addition, a score depicting the evaluators overall impression of the image was recorded. Images acquired with cone beam CT were found to be significantly superior in image quality to images acquired with 64-multidetector row CT overall, and in all scored categories. In our study setting cone beam CT was found to be a valid and clinically superior imaging modality for the canine maxillary dentoalveolar structures when compared to 64-multidetector row CT.
Bolliger, Stephan A; Ross, Steffen; Thali, Michael J; Hostettler, Bernhard; Menkveld-Gfeller, Ursula
2012-01-01
The study of fossils permits the reconstruction of past life on our planet and enhances our understanding of evolutionary processes. However, many fossils are difficult to recognize, being encased in a lithified matrix whose tedious removal is required before examination is possible. The authors describe the use of multidetector computed tomography (CT) in locating, identifying, and examining fossil remains of crocodilians (Mesosuchia) embedded in hard shale, all without removing the matrix. In addition, they describe how three-dimensional (3D) reformatted CT images provided details that were helpful for extraction and preparation. Multidetector CT can help experienced paleontologists localize and characterize fossils in the matrix of a promising rock specimen in a nondestructive manner. Moreover, with its capacity to generate highly accurate 3D images, multidetector CT can help determine whether the fossils warrant extraction and can assist in planning the extraction process. Thus, multidetector CT may well become an invaluable tool in the field of paleoradiology.
Diagnosis and classification of pancreatic and duodenal injuries in emergency radiology.
Linsenmaier, Ulrich; Wirth, Stefan; Reiser, Maximilian; Körner, Markus
2008-10-01
Pancreatic and duodenal injuries after blunt abdominal trauma are rare; however, delays in diagnosis and treatment can significantly increase morbidity and mortality. Multidetector computed tomography (CT) has a major role in early diagnosis of pancreatic and duodenal injuries. Detecting the often subtle signs of injury with whole-body CT can be difficult because this technique usually does not include a dedicated protocol for scanning the pancreas. Specific injury patterns in the pancreas and duodenum often have variable expression at early posttraumatic multidetector CT: They may be hardly visible, or there may be considerable exudate, hematomas, organ ruptures, or active bleeding. An accurate multidetector CT technique allows optimized detection of subtle abnormalities. In duodenal injuries, differentiation between a contusion of the duodenal wall or mural hematoma and a duodenal perforation is vital. In pancreatic injuries, determination of involvement of the pancreatic duct is essential. The latter conditions require immediate surgical intervention. Use of organ injury scales and a surgical classification adapted for multidetector CT enables classification of organ injuries for trauma scoring, treatment planning, and outcome control. In addition, multidetector CT reliably demonstrates potential complications of duodenal and pancreatic injuries, such as posttraumatic pancreatitis, pseudocysts, fistulas, exudates, and abscesses. (c) RSNA, 2008.
Kumar, Sheo; Neyaz, Zafar; Gupta, Archna
2010-01-01
The increased use of laparoscopic nephrectomy and nephron-sparing surgery has prompted the need for a more detailed radiological evaluation of the renal vascular anatomy. Multidetector CT angiography is a fast and accurate modality for assessing the precise anatomy of the renal vessels. In this pictorial review, we present the multidetector CT angiography appearances of the normal renal vascular anatomy and a spectrum of various anomalies that require accurate vascular depiction before undergoing surgical treatment.
Kim, Bo Ram; Lee, Jeong Min; Lee, Dong Ho; Yoon, Jeong Hee; Hur, Bo Yun; Suh, Kyung Suk; Yi, Nam-Joon; Lee, Kyung Boon; Han, Joon Koo
2017-10-01
Purpose To compare the diagnostic performance of gadoxetic acid-enhanced liver magnetic resonance (MR) imaging with that of contrast material-enhanced multidetector computed tomography (CT) in the detection of borderline hepatocellular nodules in patients with liver cirrhosis and to determine the Liver Imaging Reporting and Data System (LI-RADS) categories of these detected nodules. Materials and Methods The institutional review board approved this retrospective study and waived the informed consent requirement. Sixty-eight patients with pathologically proven dysplastic nodules (DNs) (low-grade DNs, n = 20; high-grade DNs, n = 17), early hepatocellular carcinomas (HCCs) (n = 42), or progressed HCCs (n = 33) underwent gadoxetic acid-enhanced MR imaging and multidetector CT. An additional 57 patients without any DNs or HCCs in the explanted livers were included as control subjects. Three radiologists independently graded the presence of liver nodules on a five-point confidence scale and assigned LI-RADS categories by using imaging findings. Jackknife alternative free-response receiver operating characteristics (JAFROC) software was used to compare the diagnostic accuracy of each modality in lesion detection. Results Reader-averaged figures of merit estimated with JAFROC software to detect hepatocellular nodules were 0.774 for multidetector CT and 0.842 for MR imaging (P = .002). Readers had significantly higher detection sensitivity for early HCCs with MR imaging than with multidetector CT (78.6% vs 52.4% [P = .001], 71.4% vs 50.0% [P = .011], and 73.8% vs 50.0% [P = .001], respectively). A high proportion of overall detected early HCCs at multidetector CT (59.4%) and MR imaging (72.3%) were categorized as LI-RADS category 4. Most early HCCs (76.2%) and high-grade DNs (82.4%) demonstrated hypointensity on hepatobiliary phase images. In total, 30 more LI-RADS category 4 early HCCs were identified with MR imaging than with multidetector CT across all readers. Conclusion Gadoxetic acid-enhanced MR imaging performed significantly better in the detection of high-risk borderline nodules, especially early HCCs, than did multidetector CT. © RSNA, 2017 Online supplemental material is available for this article.
De Maeseneer, M; Buls, N; Cleeren, N; Lenchik, L; De Mey, J
2006-01-01
We present an unusual application of multidetector CT and shaded surface rendering in the investigation of a soil sample, containing an ancient Roman bronze bowl. The CT findings were of fundamental importance in helping the archaeologists study the bronze bowl from the soil sample.
Relationship between noise, dose, and pitch in cardiac multi-detector row CT.
Primak, Andrew N; McCollough, Cynthia H; Bruesewitz, Michael R; Zhang, Jie; Fletcher, Joel G
2006-01-01
In spiral computed tomography (CT), dose is always inversely proportional to pitch. However, the relationship between noise and pitch (and hence noise and dose) depends on the scanner type (single vs multi-detector row) and reconstruction mode (cardiac vs noncardiac). In single detector row spiral CT, noise is independent of pitch. Conversely, in noncardiac multi-detector row CT, noise depends on pitch because the spiral interpolation algorithm makes use of redundant data from different detector rows to decrease noise for pitch values less than 1 (and increase noise for pitch values > 1). However, in cardiac spiral CT, redundant data cannot be used because such data averaging would degrade the temporal resolution. Therefore, the behavior of noise versus pitch returns to the single detector row paradigm, with noise being independent of pitch. Consequently, since faster rotation times require lower pitch values in cardiac multi-detector row CT, dose is increased without a commensurate decrease in noise. Thus, the use of faster rotation times will improve temporal resolution, not alter noise, and increase dose. For a particular application, the higher dose resulting from faster rotation speeds should be justified by the clinical benefits of the improved temporal resolution. RSNA, 2006
Wyler, Annabelle; Bousson, Valérie; Bergot, Catherine; Polivka, Marc; Leveque, Eric; Vicaut, Eric; Laredo, Jean-Denis
2007-02-01
To assess spiral multidetector computed tomographic (CT) arthrography for the depiction of cartilage thickness in hips without cartilage loss, with evaluation of anatomic slices as the reference standard. Permission to perform imaging studies in cadaveric specimens of individuals who had willed their bodies to science was obtained from the institutional review board. Two independent observers measured the femoral and acetabular hyaline cartilage thickness of 12 radiographically normal cadaveric hips (from six women and five men; age range at death, 52-98 years; mean, 76.5 years) on spiral multidetector CT arthrographic reformations and on coronal anatomic slices. Regions of cartilage loss at gross or histologic examination were excluded. CT arthrographic and anatomic measurements in the coronal plane were compared by using Bland-Altman representation and a paired t test. Differences between mean cartilage thicknesses at the points of measurement were tested by means of analysis of variance. Interobserver and intraobserver reproducibilities were determined. At CT arthrography, mean cartilage thickness ranged from 0.32 to 2.53 mm on the femoral head and from 0.95 to 3.13 mm on the acetabulum. Observers underestimated cartilage thickness in the coronal plane by 0.30 mm +/- 0.52 (mean +/- standard error) at CT arthrography (P < .001) compared with the anatomic reference standard. Ninety-five percent of the differences between CT arthrography and anatomic values ranged from -1.34 to 0.74 mm. The difference between mean cartilage thicknesses at the different measurement points was significant for coronal spiral multidetector CT arthrography and anatomic measurement of the femoral head and acetabulum and for sagittal and transverse CT arthrography of the femoral head (P < .001). Changes in cartilage thickness from the periphery to the center of the joint ("gradients") were found by means of spiral multidetector CT arthrography and anatomic measurement. Spiral multidetector CT arthrography depicts cartilage thickness gradients in radiographically normal cadaveric hips. (c) RSNA, 2007.
Patent foramen ovale: detection with nongated multidetector CT.
Revel, Marie-Pierre; Faivre, Jean-Baptiste; Letourneau, Thierry; Henon, Hilde; Leys, Didier; Delannoy-Deken, Valérie; Remy-Jardin, Martine; Remy, Jacques
2008-10-01
To evaluate nongated multidetector computed tomography (CT) in the detection of patent foramen ovale (PFO) and atrial septal aneurysm (ASA) in comparison with transesophageal echocardiography (TEE). The study was approved by the institutional review board, and informed consent was obtained from all patients. One hundred five patients (57 men, 48 women; mean age, 53 years) with a recent stroke underwent TEE and multidetector CT on the same day. After injection of a diluted iodinated contrast material, a series of 2.4-mm-thick transverse images centered on the fossa ovalis were acquired in conjunction with release of the Valsalva maneuver. Two independent radiologists considered PFO present if left atrial enhancement was detected visually before enhancement of the pulmonary veins or if an early peak of left atrial enhancement was found at time-attenuation curve analysis. PFO was detected with 98% specificity (95% confidence interval [CI]: 0.91, 0.99). Overall sensitivity was 55% (95% CI: 0.38, 0.70), ranging from 28% for shunts classified as grade 1 at TEE to 91% for those classified as grade 4 at TEE. Interreader agreement was good (kappa = 0.81). Visual assessment was better than time-attenuation curve analysis, which enabled detection of only 15 of the 40 cases of PFO. Multidetector CT depicted only 22% of cases of ASA. The mean effective radiation dose was 2.3 mSv. Nongated multidetector CT can be used to diagnose high-grade shunts through a PFO, with 91% sensitivity and 98% specificity. Thus, PFO detection, in addition to routine CT evaluation of the lungs, could be indicated in patients with unexplained hypoxemia. (c) RSNA, 2008.
Fayad, Laura M; Johnson, Pamela; Fishman, Elliot K
2005-01-01
Computed tomography (CT) plays an important role in the evaluation of musculoskeletal disease in the pediatric patient. With the advent of high-performance 16-section multidetector CT, images can be produced with subsecond gantry rotation times and with submillimeter acquisition, which yields true isotropic high-resolution volume data sets; these features are not attainable with older spiral CT technology. Such capabilities are particularly helpful in the evaluation of pediatric patients by virtually eliminating the need for sedation and minimizing dependence on patient cooperation. The role of three-dimensional (3D) volume imaging in the evaluation of pediatric musculoskeletal disease continues to evolve, with this technique becoming increasingly important in detection and characterization of lesions as well as in decisions about patient care. Specific designs and protocols for multidetector CT studies can be selected to minimize radiation dose to the patient. Principal clinical applications of 3D CT in evaluation of the pediatric musculoskeletal system include developmental abnormalities, trauma, neoplasms, and postoperative imaging.
Multidetector CT of blunt traumatic venous injuries in the chest, abdomen, and pelvis.
Holly, Brian P; Steenburg, Scott D
2011-01-01
Venous injuries as a result of blunt trauma are rare. Even though current protocols for multidetector computed tomography (CT) of patients with trauma are designed to evaluate primarily the solid organs and arteries, blunt venous injuries may nevertheless be identified, or at least suspected, on the basis of the multidetector CT findings. Venous injuries are associated with high morbidity and mortality rates. Diagnosis of a possible venous injury is crucial because the physical findings of a venous injury are nonspecific and may be absent. This article aims to make the radiologist aware of various venous injuries caused by blunt trauma and to provide helpful hints to aid in the identification of venous injuries. Multidetector CT technology, in combination with interactive manipulation of the raw dataset, can be useful in the creation of multiplanar reconstructed images and in the identification of a venous injury caused by blunt trauma. Familiarity with direct and indirect signs of venous injuries, as well as with examples of blunt traumatic venous injuries in the chest, abdomen, and pelvis, will help in the diagnosis of these injuries.
T staging of gastric cancer: role of multi-detector row CT.
Kumano, Seishi; Murakami, Takamichi; Kim, Tonsok; Hori, Masatoshi; Iannaccone, Riccardo; Nakata, Saki; Onishi, Hiromitsu; Osuga, Keigo; Tomoda, Kaname; Catalano, Carlo; Nakamura, Hironobu
2005-12-01
To evaluate retrospectively the accuracy of multi-detector row computed tomography (CT) in the assessment of serosal invasion in patients with gastric cancer. The Ethics Committee does not require approval or informed consent for retrospective studies. Forty-one consecutive patients (24 men, 17 women; mean age, 68 years) with gastric cancer were included in this study. All patients were given 600 mL of tap water to drink and were positioned prone or supine on the scanning table. The detector row configuration included four detector rows, a section thickness of 1.25 mm, a pitch of 6, and a reconstruction interval of 0.63 mm. Transverse and multiplanar reconstruction images were simultaneously evaluated by two independent observers to assess the depth of tumor invasion in the gastric wall (ie, T stage). T staging at multi-detector row CT was compared with T staging at histologic evaluation (reference standard), which was performed by means of surgical or histologic examination of the resected specimen. We also calculated the sensitivity, specificity, and accuracy of multi-detector row CT for each observer in the assessment of serosal invasion. Analysis of interobserver agreement showed substantial or almost perfect agreement (nonweighted kappa value of 0.78 and weighted kappa value of 0.85). Correct assessment of gastric wall invasion was 80% and 85% for observers 1 and 2, respectively. The sensitivity, specificity, and accuracy of multi-detector row CT in the assessment of serosal invasion were 90%, 95%, and 93%, respectively, for observer 1 and 80%, 97%, and 93%, respectively, for observer 2. Overstaging occurred in six patients, and understaging occurred in five patients. All understaged tumors were scirrhous subtype gastric cancer. Multi-detector row CT scanning of patients with gastric cancer gave 93% accuracy in the assessment of serosal invasion in patients with gastric cancer. RSNA, 2005
Caro-Domínguez, Pablo; Compton, Gregory; Humpl, Tilman; Manson, David E
2016-09-01
The ratio of the transverse diameter of the main pulmonary artery (MPA) to ascending aorta as determined at multi-detector CT is a tool that can be used to assess the pulmonary arterial size in cases of pulmonary arterial hypertension in children. To establish a ratio of MPA to ascending aorta diameter using multi-detector CT imaging suggestive of pulmonary arterial hypertension in children. We hypothesize that a defined ratio of MPA to ascending aorta is identifiable on multi-detector CT and that higher ratios can be used to reliably diagnose the presence of pulmonary arterial hypertension in children. We calculated the multi-detector CT ratio of MPA to ascending aorta diameter in 44 children with documented pulmonary arterial hypertension by right heart catheterization and in 44 age- and gender-matched control children with no predisposing factors for pulmonary arterial hypertension. We compared this multi-detector-CT-determined ratio with the MPA pressure in the study group, as well as with the ratio of MPA to ascending aorta in the control group. A threshold ratio value was calculated to accurately identify children with pulmonary arterial hypertension. Children with documented primary pulmonary arterial hypertension have a significantly higher ratio of MPA to ascending aorta (1.46) than children without pulmonary arterial hypertension (1.11). A ratio of 1.3 carries a positive likelihood of 34 and a positive predictive value of 97% for the diagnosis of pulmonary arterial hypertension. The pulmonary arteries were larger in children with pulmonary arterial hypertension than in a control group of normal children. A CT-measured ratio of MPA to ascending aorta of 1.3 should raise the suspicion of pulmonary arterial hypertension in children.
Multi-detector row computed tomography angiography of peripheral arterial disease
Dijkshoorn, Marcel L.; Pattynama, Peter M. T.; Myriam Hunink, M. G.
2007-01-01
With the introduction of multi-detector row computed tomography (MDCT), scan speed and image quality has improved considerably. Since the longitudinal coverage is no longer a limitation, multi-detector row computed tomography angiography (MDCTA) is increasingly used to depict the peripheral arterial runoff. Hence, it is important to know the advantages and limitations of this new non-invasive alternative for the reference test, digital subtraction angiography. Optimization of the acquisition parameters and the contrast delivery is important to achieve a reliable enhancement of the entire arterial runoff in patients with peripheral arterial disease (PAD) using fast CT scanners. The purpose of this review is to discuss the different scanning and injection protocols using 4-, 16-, and 64-detector row CT scanners, to propose effective methods to evaluate and to present large data sets, to discuss its clinical value and major limitations, and to review the literature on the validity, reliability, and cost-effectiveness of multi-detector row CT in the evaluation of PAD. PMID:17882427
Imaging of acute mesenteric ischemia using multidetector CT and CT angiography in a porcine model.
Rosow, David E; Sahani, Dushyant; Strobel, Oliver; Kalva, Sanjeeva; Mino-Kenudson, Mari; Holalkere, Nagaraj S; Alsfasser, Guido; Saini, Sanjay; Lee, Susanna I; Mueller, Peter R; Fernández-del Castillo, Carlos; Warshaw, Andrew L; Thayer, Sarah P
2005-12-01
Acute mesenteric ischemia, a frequently lethal disease, requires prompt diagnosis and intervention for favorable clinical outcomes. This goal remains elusive due, in part, to lack of a noninvasive and accurate imaging study. Traditional angiography is the diagnostic gold standard but is invasive and costly. Computed tomography (CT) is readily available and noninvasive but has shown variable success in diagnosing this disease. The faster scanning time of multidetector row CT (M.D.CT) greatly facilitates the use of CT angiography (CTA) in the clinical setting. We sought to determine whether M.D.CT-CTA could accurately demonstrate vascular anatomy and capture the earliest stages of mesenteric ischemia in a porcine model. Pigs underwent embolization of branches of the superior mesenteric artery, then imaging by M.D.CT-CTA with three-dimensional reconstruction protocols. After scanning, diseased bowel segments were surgically resected and pathologically examined. Multidetector row CT and CT angiography reliably defined normal and occluded mesenteric vessels in the pig. It detected early changes of ischemia including poor arterial enhancement and venous dilatation, which were seen in all ischemic animals. The radiographic findings--compared with pathologic diagnoses-- predicted ischemia, with a positive predictive value of 92%. These results indicate that M.D.CT-CTA holds great promise for the early detection necessary for successful treatment of acute mesenteric ischemia.
... Computed tomography scan - heart; Calcium scoring; Multi-detector CT scan - heart; Electron beam computed tomography - heart; Agatston ... table that slides into the center of the CT scanner. You will lie on your back with ...
Aubry, S; Pousse, A; Sarliève, P; Laborie, L; Delabrousse, E; Kastler, B
2006-11-01
To model vertebrae in 3D to improve radioanatomic knowledge of the spine with the vascular and nerve environment and simulate CT-guided interventions. Vertebra acquisitions were made with multidetector CT. We developed segmentation software and specific viewer software using the Delphi programming environment. This segmentation software makes it possible to model 3D high-resolution segments of vertebrae and their environment from multidetector CT acquisitions. Then the specific viewer software provides multiplanar reconstructions of the CT volume and the possibility to select different 3D objects of interest. This software package improves radiologists' radioanatomic knowledge through a new 3D anatomy presentation. Furthermore, the possibility of inserting virtual 3D objects in the volume can simulate CT-guided intervention. The first volumetric radioanatomic software has been born. Furthermore, it simulates CT-guided intervention and consequently has the potential to facilitate learning interventions using CT guidance.
Omura, Kensuke; Ota, Hideki; Takahashi, Yuuki; Matsuura, Tomonori; Seiji, Kazumasa; Arai, Yoichi; Morimoto, Ryo; Satoh, Fumitoshi; Takase, Kei
2017-03-01
Adrenal venous sampling is the most reliable diagnostic procedure to determine surgical indications in primary aldosteronism. Because guidelines recommend multidetector computed tomography (CT) to evaluate the adrenal gland, some past reports used multidetector CT as a guide for adrenal venous sampling. However, the detailed anatomy of the right adrenal vein and its relationship with an accessory hepatic vein remains uncertain. The purpose of this study was to describe detailed anatomical variations of the right adrenal vein and to determine the concordance between CT and catheter venography in patients with primary aldosteronism. In total, 440 consecutive patients who underwent adrenal venous sampling were included. Four-phase dynamic CT was performed. Anatomical locations and variations of the right adrenal vein and its relationship with the accessory hepatic vein were compared with catheter venographic findings. Successful catheterization was achieved in 437 patients (99%). The right adrenal vein was visualized in the late arterial phase with CT in 420 patients (95%). The right adrenal vein formed a common trunk with the accessory hepatic vein in 87 patients (20%). CT identified the correct craniocaudal level of the orifice in 354 patients (84%). Anatomical variations, location, and angle of inflow of the right adrenal vein based on CT demonstrated high concordance with catheter venography. CT may provide useful information for preparation before adrenal venous sampling. © 2017 American Heart Association, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Xiaohua; Yuan, Huishu; Duan, Jianghui
2013-08-15
Purpose: The purpose of this study was to evaluate the effect of various computed tomography (CT) thresholds on trapping volumetric measurements by multidetector CT in chronic obstructive pulmonary disease (COPD).Methods: Twenty-three COPD patients were scanned with a 64-slice CT scanner in both the inspiratory and expiratory phase. CT thresholds of −950 Hu in inspiration and −950 to −890 Hu in expiration were used, after which trapping volumetric measurements were made using computer software. Trapping volume percentage (Vtrap%) under the different CT thresholds in the expiratory phase and below −950 Hu in the inspiratory phase was compared and correlated with lungmore » function.Results: Mean Vtrap% was similar under −930 Hu in the expiratory phase and below −950 Hu in the inspiratory phase, being 13.18 ± 9.66 and 13.95 ± 6.72 (both lungs), respectively; this difference was not significant (P= 0.240). Vtrap% under −950 Hu in the inspiratory phase and below the −950 to −890 Hu threshold in the expiratory phase was moderately negatively correlated with the ratio of forced expiratory volume in one second to forced vital capacity and the measured value of forced expiratory volume in one second as a percentage of the predicted value.Conclusions: Trapping volumetric measurement with multidetector CT is a promising method for the quantification of COPD. It is important to know the effect of various CT thresholds on trapping volumetric measurements.« less
Akpinar, Erhan; Türkbey, Bariş; Cil, Barbaros Erhan; Canyiğit, Murat; Dündar, Ziya; Balkanci, Ferhun
2007-06-01
Acute lower gastrointestinal system (GIS) bleeding is a life-threatening condition. Immediate determination of the origin of the bleeding is crucial, since hemostatic management must be initiated as rapidly as possible. Colonoscopy, radionuclide studies, and conventional angiography are considered the most important methods for assessing the origin of the bleeding. There are few published reports about the feasibility of computed tomography (CT) in acute GIS bleeding. We present multidetector CT (MDCT) findings in a case of Hodgkin disease status one month post-chemotherapy (CHOP protocol; cyclophosphamide, doxorubicin, vincristine, prednisone) that presented with acute lower GIS bleeding.
Multi-detector CT imaging in the postoperative orthopedic patient with metal hardware.
Vande Berg, Bruno; Malghem, Jacques; Maldague, Baudouin; Lecouvet, Frederic
2006-12-01
Multi-detector CT imaging (MDCT) becomes routine imaging modality in the assessment of the postoperative orthopedic patients with metallic instrumentation that degrades image quality at MR imaging. This article reviews the physical basis and CT appearance of such metal-related artifacts. It also addresses the clinical value of MDCT in postoperative orthopedic patients with emphasis on fracture healing, spinal fusion or arthrodesis, and joint replacement. MDCT imaging shows limitations in the assessment of the bone marrow cavity and of the soft tissues for which MR imaging remains the imaging modality of choice despite metal-related anatomic distortions and signal alteration.
Kim, Young Jin; Hur, Jin; Shim, Chi-Young; Lee, Hye-Jeong; Ha, Jong-Won; Choe, Kyu Ok; Heo, Ji Hoe; Choi, Eui-Young; Choi, Byoung Wook
2009-01-01
To evaluate the clinical feasibility and accuracy of 64-section multidetector computed tomography (CT) compared with transesophageal echocardiography (TEE) for diagnosis of a patent foramen ovale (PFO). Institutional review board approval was obtained for this retrospective study. The study included 152 consecutive stroke patients (mean age, 61.7 years; 98 men, 54 women) who underwent both cardiac multidetector CT and TEE. Electrocardiographically gated cardiac CT was performed with a 64-section CT scanner by using a saline-chaser contrast agent injection technique. A contrast agent jet from the contrast agent-filled left atrium (LA) to the saline-filled right atrium (RA) and channel-like appearance of the interatrial septum (IAS) were evaluated on axial and oblique sagittal CT images. Two-dimensional and Doppler TEE were performed to detect PFO. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of CT were obtained with TEE as the reference standard. A PFO was present in 26 patients at TEE. On CT images, a left-to-right contrast agent jet toward the inferior vena cava was noted in 21 patients (sensitivity, 73.1%; specificity, 98.4%; PPV, 90.5%; NPV, 94.7%). Channel-like appearance of the IAS was detected in 38 patients (sensitivity, 76.9%; specificity, 85.7%; PPV, 52.6%; NPV, 94.7%). Channel-like appearance of the IAS was noted in all patients who had a contrast agent jet. A contrast agent jet from LA to RA toward the inferior vena cava with channel-like appearance of the IAS on CT images confirms the presence of a PFO. (c) RSNA, 2008.
Femoral head avascular necrosis: a frequently missed incidental finding on multidetector CT.
Barille, M F; Wu, Jim S; McMahon, Colm J
2014-03-01
To determine the incidence of missed femoral head avascular necrosis (AVN) on pelvic computed tomography (CT) performed for clinical indications other than assessment for AVN. The study was a Health Insurance Portability and Accountability Act (HIPAA)-compliant retrospective study. The picture archiving and communication system (PACS) database was queried for patients with diagnosis of femoral head AVN on magnetic resonance imaging (MRI), who also underwent pelvic multidetector CT after or <30 days before the MRI examination. The MRI and CT images of 144 hips of 72 patients (39 patients with reported AVN on MRI and 33 age-matched controls; mean age = 60 years, 28 male, 44 female), were reviewed in consensus by two readers in a randomized, blinded manner. Using MRI-proven CT-visible AVN as a reference standard, the incidence of missed AVN on initial CT interpretation was determined. Readers confirmed AVN in 33 patients on the MRI images. Nine hips with AVN underwent joint replacement of the affected joint(s) prior to subsequent CT and were excluded. Forty-three MRI-proven AVN cases in 28 patients (15 bilateral, 13 unilateral) were available for analysis. The study readers diagnosed 35/43 (81%) MRI-proven AVN cases in 22/28 (79%) patients. Four of the 35 (11%) cases of MRI-proven, CT-visible AVN were prospectively reported in 3/22 (14%) patients at initial clinical interpretation, with a miss rate of 89% per hip and 86% per patient. Multidetector CT has high accuracy for detection of AVN; however, this is frequently missed as an incidental finding (89% missed in the present study). Assessment for signs of femoral AVN should be part of routine search pattern in interpretation of pelvic CT. Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
The impact of manual threshold selection in medical additive manufacturing.
van Eijnatten, Maureen; Koivisto, Juha; Karhu, Kalle; Forouzanfar, Tymour; Wolff, Jan
2017-04-01
Medical additive manufacturing requires standard tessellation language (STL) models. Such models are commonly derived from computed tomography (CT) images using thresholding. Threshold selection can be performed manually or automatically. The aim of this study was to assess the impact of manual and default threshold selection on the reliability and accuracy of skull STL models using different CT technologies. One female and one male human cadaver head were imaged using multi-detector row CT, dual-energy CT, and two cone-beam CT scanners. Four medical engineers manually thresholded the bony structures on all CT images. The lowest and highest selected mean threshold values and the default threshold value were used to generate skull STL models. Geometric variations between all manually thresholded STL models were calculated. Furthermore, in order to calculate the accuracy of the manually and default thresholded STL models, all STL models were superimposed on an optical scan of the dry female and male skulls ("gold standard"). The intra- and inter-observer variability of the manual threshold selection was good (intra-class correlation coefficients >0.9). All engineers selected grey values closer to soft tissue to compensate for bone voids. Geometric variations between the manually thresholded STL models were 0.13 mm (multi-detector row CT), 0.59 mm (dual-energy CT), and 0.55 mm (cone-beam CT). All STL models demonstrated inaccuracies ranging from -0.8 to +1.1 mm (multi-detector row CT), -0.7 to +2.0 mm (dual-energy CT), and -2.3 to +4.8 mm (cone-beam CT). This study demonstrates that manual threshold selection results in better STL models than default thresholding. The use of dual-energy CT and cone-beam CT technology in its present form does not deliver reliable or accurate STL models for medical additive manufacturing. New approaches are required that are based on pattern recognition and machine learning algorithms.
High resolution multidetector CT aided tissue analysis and quantification of lung fibrosis
NASA Astrophysics Data System (ADS)
Zavaletta, Vanessa A.; Karwoski, Ronald A.; Bartholmai, Brian; Robb, Richard A.
2006-03-01
Idiopathic pulmonary fibrosis (IPF, also known as Idiopathic Usual Interstitial Pneumontis, pathologically) is a progressive diffuse lung disease which has a median survival rate of less than four years with a prevalence of 15-20/100,000 in the United States. Global function changes are measured by pulmonary function tests and the diagnosis and extent of pulmonary structural changes are typically assessed by acquiring two-dimensional high resolution CT (HRCT) images. The acquisition and analysis of volumetric high resolution Multi-Detector CT (MDCT) images with nearly isotropic pixels offers the potential to measure both lung function and structure. This paper presents a new approach to three dimensional lung image analysis and classification of normal and abnormal structures in lungs with IPF.
Tonolini, Massimo
2016-01-01
Inguinal hernia repair (IHR) with prosthetic mesh implantation is the most common procedure in general surgery, and may be performed using either an open or laparoscopic approach. This paper provides an overview of contemporary tension-free IHR techniques and materials, and illustrates the expected postoperative imaging findings and iatrogenic injuries. Emphasis is placed on multidetector CT, which represents the ideal modality to comprehensively visualize the operated groin region and deeper intra-abdominal structures. CT consistently depicts seroma, mesh infections, hemorrhages, bowel complications and urinary bladder injuries, and thus generally provides a consistent basis for therapeutic choice. Since radiologists are increasingly requested to investigate suspected iatrogenic complications, this paper aims to provide an increased familiarity with early CT studies after IHR, including complications and normal postoperative appearances such as focal pseudolesions, in order to avoid misinterpretation and inappropriate management. PMID:27460285
Kakimoto, Naoya; Chindasombatjaroen, Jira; Tomita, Seiki; Shimamoto, Hiroaki; Uchiyama, Yuka; Hasegawa, Yoko; Kishino, Mitsunobu; Murakami, Shumei; Furukawa, Souhei
2013-01-01
The purpose of this study was to investigate the usefulness of computerized tomography (CT), particularly contrast-enhanced CT, in differentiation of jaw cysts and cystic-appearing tumors. We retrospectively analyzed contrast-enhanced CT images of 90 patients with odontogenic jaw cysts or cystic-appearing tumors. The lesion size and CT values were measured and the short axis to long axis (S/L) ratio, contrast enhancement (CE) ratio, and standard deviation ratio were calculated. The lesion size and the S/L ratio of keratocystic odontogenic tumors were significantly different from those of radicular cysts and follicular cysts. There were no significant differences in the CE ratio among the lesions. Multidetector CT provided diagnostic information about the size of odontogenic cysts and cystic-appearing tumors of the jaws that was related to the lesion type, but showed no relation between CE ratio and the type of these lesions. Copyright © 2013 Elsevier Inc. All rights reserved.
Dong, J; Hayakawa, Y; Kober, C
2014-01-01
When metallic prosthetic appliances and dental fillings exist in the oral cavity, the appearance of metal-induced streak artefacts is not avoidable in CT images. The aim of this study was to develop a method for artefact reduction using the statistical reconstruction on multidetector row CT images. Adjacent CT images often depict similar anatomical structures. Therefore, reconstructed images with weak artefacts were attempted using projection data of an artefact-free image in a neighbouring thin slice. Images with moderate and strong artefacts were continuously processed in sequence by successive iterative restoration where the projection data was generated from the adjacent reconstructed slice. First, the basic maximum likelihood-expectation maximization algorithm was applied. Next, the ordered subset-expectation maximization algorithm was examined. Alternatively, a small region of interest setting was designated. Finally, the general purpose graphic processing unit machine was applied in both situations. The algorithms reduced the metal-induced streak artefacts on multidetector row CT images when the sequential processing method was applied. The ordered subset-expectation maximization and small region of interest reduced the processing duration without apparent detriments. A general-purpose graphic processing unit realized the high performance. A statistical reconstruction method was applied for the streak artefact reduction. The alternative algorithms applied were effective. Both software and hardware tools, such as ordered subset-expectation maximization, small region of interest and general-purpose graphic processing unit achieved fast artefact correction.
Broad ligament hernia successfully treated by laparoscopy: Case report and review of literature.
Matsunami, Masatoshi; Kusanagi, Hiroshi; Hayashi, Ken; Yamada, Shigetoshi; Kano, Nobuyasu
2014-11-01
We report a case of a 36-year-old woman with a history of caesarean section who presented with small bowel obstruction. Abdominal multi-detector CT showed discontinuity of the small bowel near the broad ligament on the left. We made a provisional diagnosis of an internal hernia through a defect in the broad ligament and performed laparoscopic exploration, which revealed a viable ileal loop incarcerated by the broad ligament. Multi-detector CT may be useful for diagnosing this type of defect preoperatively, whereby open surgery can be avoided. © 2014 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and Wiley Publishing Asia Pty Ltd.
Solomon, Justin; Mileto, Achille; Nelson, Rendon C; Roy Choudhury, Kingshuk; Samei, Ehsan
2016-04-01
To determine if radiation dose and reconstruction algorithm affect the computer-based extraction and analysis of quantitative imaging features in lung nodules, liver lesions, and renal stones at multi-detector row computed tomography (CT). Retrospective analysis of data from a prospective, multicenter, HIPAA-compliant, institutional review board-approved clinical trial was performed by extracting 23 quantitative imaging features (size, shape, attenuation, edge sharpness, pixel value distribution, and texture) of lesions on multi-detector row CT images of 20 adult patients (14 men, six women; mean age, 63 years; range, 38-72 years) referred for known or suspected focal liver lesions, lung nodules, or kidney stones. Data were acquired between September 2011 and April 2012. All multi-detector row CT scans were performed at two different radiation dose levels; images were reconstructed with filtered back projection, adaptive statistical iterative reconstruction, and model-based iterative reconstruction (MBIR) algorithms. A linear mixed-effects model was used to assess the effect of radiation dose and reconstruction algorithm on extracted features. Among the 23 imaging features assessed, radiation dose had a significant effect on five, three, and four of the features for liver lesions, lung nodules, and renal stones, respectively (P < .002 for all comparisons). Adaptive statistical iterative reconstruction had a significant effect on three, one, and one of the features for liver lesions, lung nodules, and renal stones, respectively (P < .002 for all comparisons). MBIR reconstruction had a significant effect on nine, 11, and 15 of the features for liver lesions, lung nodules, and renal stones, respectively (P < .002 for all comparisons). Of note, the measured size of lung nodules and renal stones with MBIR was significantly different than those for the other two algorithms (P < .002 for all comparisons). Although lesion texture was significantly affected by the reconstruction algorithm used (average of 3.33 features affected by MBIR throughout lesion types; P < .002, for all comparisons), no significant effect of the radiation dose setting was observed for all but one of the texture features (P = .002-.998). Radiation dose settings and reconstruction algorithms affect the extraction and analysis of quantitative imaging features in lesions at multi-detector row CT.
NASA Astrophysics Data System (ADS)
Belinato, W.; Santos, W. S.; Paschoal, C. M. M.; Souza, D. N.
2015-06-01
The combination of positron emission tomography (PET) and computed tomography (CT) has been extensively used in oncology for diagnosis and staging of tumors, radiotherapy planning and follow-up of patients with cancer, as well as in cardiology and neurology. This study determines by the Monte Carlo method the internal organ dose deposition for computational phantoms created by multidetector CT (MDCT) beams of two PET/CT devices operating with different parameters. The different MDCT beam parameters were largely related to the total filtration that provides a beam energetic change inside the gantry. This parameter was determined experimentally with the Accu-Gold Radcal measurement system. The experimental values of the total filtration were included in the simulations of two MCNPX code scenarios. The absorbed organ doses obtained in MASH and FASH phantoms indicate that bowtie filter geometry and the energy of the X-ray beam have significant influence on the results, although this influence can be compensated by adjusting other variables such as the tube current-time product (mAs) and pitch during PET/CT procedures.
Moores, L; Kline, J; Portillo, A K; Resano, S; Vicente, A; Arrieta, P; Corres, J; Tapson, V; Yusen, R D; Jiménez, D
2016-01-01
ESSENTIALS: When high probability of pulmonary embolism (PE), sensitivity of computed tomography (CT) is unclear. We investigated the sensitivity of multidetector CT among 134 patients with a high probability of PE. A normal CT alone may not safely exclude PE in patients with a high clinical pretest probability. In patients with no clear alternative diagnosis after CTPA, further testing should be strongly considered. Whether patients with a negative multidetector computed tomographic pulmonary angiography (CTPA) result and a high clinical pretest probability of pulmonary embolism (PE) should be further investigated is controversial. This was a prospective investigation of the sensitivity of multidetector CTPA among patients with a priori clinical assessment of a high probability of PE according to the Wells criteria. Among patients with a negative CTPA result, the diagnosis of PE required at least one of the following conditions: ventilation/perfusion lung scan showing a high probability of PE in a patient with no history of PE, abnormal findings on venous ultrasonography in a patient without previous deep vein thrombosis at that site, or the occurrence of venous thromboembolism (VTE) in a 3-month follow-up period after anticoagulation was withheld because of a negative multidetector CTPA result. We identified 498 patients with a priori clinical assessment of a high probability of PE and a completed CTPA study. CTPA excluded PE in 134 patients; in these patients, the pooled incidence of VTE was 5.2% (seven of 134 patients; 95% confidence interval [CI] 1.5-9.0). Five patients had VTEs that were confirmed by an additional imaging test despite a negative CTPA result (five of 48 patients; 10.4%; 95% CI 1.8-19.1), and two patients had objectively confirmed VTEs that occurred during clinical follow-up of at least 3 months (two of 86 patients; 2.3%; 95% CI 0-5.5). None of the patients had a fatal PE during follow-up. A normal multidetector CTPA result alone may not safely exclude PE in patients with a high clinical pretest probability. © 2015 International Society on Thrombosis and Haemostasis.
Gender differences of airway dimensions in anatomically matched sites on CT in smokers.
Kim, Yu-Il; Schroeder, Joyce; Lynch, David; Newell, John; Make, Barry; Friedlander, Adam; Estépar, Raúl San José; Hanania, Nicola A; Washko, George; Murphy, James R; Wilson, Carla; Hokanson, John E; Zach, Jordan; Butterfield, Kiel; Bowler, Russell P; Copdgene Investigators
2011-08-01
There are limited data on, and controversies regarding gender differences in the airway dimensions of smokers. Multi-detector CT (MDCT) images were analyzed to examine whether gender could explain differences in airway dimensions of anatomically matched airways in smokers. We used VIDA imaging software to analyze MDCT scans from 2047 smokers (M:F, 1021:1026) from the COPDGene® cohort. The airway dimensions were analyzed from segmental to subsubsegmental bronchi. We compared the differences of luminal area, inner diameter, wall thickness, wall area percentage (WA%) for each airway between men and women, and multiple linear regression including covariates (age, gender, body sizes, and other relevant confounding factors) was used to determine the predictors of each airway dimensions. Lumen area, internal diameter and wall thickness were smaller for women than men in all measured airway (18.4 vs 22.5 mm(2) for segmental bronchial lumen area, 10.4 vs 12.5 mm(2) for subsegmental bronchi, 6.5 vs 7.7 mm(2) for subsubsegmental bronchi, respectively p < 0.001). However, women had greater WA% in subsegmental and subsubsegmental bronchi. In multivariate regression, gender remained one of the most significant predictors of WA%, lumen area, inner diameter and wall thickness. Women smokers have higher WA%, but lower luminal area, internal diameter and airway thickness in anatomically matched airways as measured by CT scan than do male smokers. This difference may explain, in part, gender differences in the prevalence of COPD and airflow limitation.
Right heart on multidetector CT
Gopalan, D
2011-01-01
Right ventricular function plays an integral role in the pathogenesis and outcome of many cardiovascular diseases. Imaging the right ventricle has long been a challenge because of its complex geometry. In recent years there has been a tremendous expansion in multidetector row CT (MDCT) and its cardiac applications. By judicious modification of contrast medium protocol, it is possible to achieve good opacification of the right-sided cardiac chambers, thereby paving the way for exploring the overshadowed right heart. This article will describe the key features of right heart anatomy, review MDCT acquisition techniques, elaborate the various morphological and functional information that can be obtained, and illustrate some important clinical conditions associated with an abnormal right heart. PMID:22723537
Bahadir, Osman; Kosucu, Polat
2012-12-01
To objectively assess the efficacy of radiofrequency thermal ablation of inferior turbinate hypertrophy. Thirty-five patients with nasal obstruction secondary to inferior turbinate hypertrophy were prospectively enrolled. Radiofrequency energy was delivered to four sites in each inferior turbinate. Patients were evaluated before and 8 weeks after intervention. Subjective evaluation of nasal obstruction was performed using a visual analogue scale (VAS), and objective evaluation of the turbinate volume reduction was calculated using multidetector CT. Volumetric measurements of the preoperative inferior turbinate were compared with postoperative values on both sides. The great majority of patients (91.4%) exhibited subjective postoperative improvement. Mean obstruction (VAS) improved significantly from 7.45±1.48 to 3.54±1.96. Significant turbinate volume reduction was achieved by the surgery on both right and left sides [(preoperative vs. postoperative, right: 6.55±1.62cm(3) vs. 5.10±1.47cm(3), (P<0.01); left: 6.72±1.53cm(3) vs. 5.00±1.37cm(3), (P<0.01)] respectively. Radiofrequency is a safe and effective surgical procedure in reducing turbinate volume in patients with inferior turbinate hypertrophy. Multidetector CT is an objective method of assessment in detecting radiofrequency turbinate volume reduction. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Recent technologic advances in multi-detector row cardiac CT.
Halliburton, Sandra Simon
2009-11-01
Recent technical advances in multi-detector row CT have resulted in lower radiation dose, improved temporal and spatial resolution, decreased scan time, and improved tissue differentiation. Lower radiation doses have resulted from the use of pre-patient z collimators, the availability of thin-slice axial data acquisition, the increased efficiency of ECG-based tube current modulation, and the implementation of iterative reconstruction algorithms. Faster gantry rotation and the simultaneous use of two x-ray sources have led to improvements in temporal resolution, and gains in spatial resolution have been achieved through application of the flying x-ray focal-spot technique in the z-direction. Shorter scan times have resulted from the design of detector arrays with increasing numbers of detector rows and through the simultaneous use of two x-ray sources to allow higher helical pitch. Some improvement in tissue differentiation has been achieved with dual energy CT. This article discusses these recent technical advances in detail.
Raza, Mushahid; Elkhodair, Samer; Zaheer, Asif; Yousaf, Sohail
2013-11-01
A true gold standard to rule out a significant cervical spine injury in subset of blunt trauma patients with altered sensorium is still to be agreed upon. The objective of this study is to determine whether in obtunded adult patients with blunt trauma, a clinically significant injury to the cervical spine be ruled out on the basis of a normal multidetector cervical spine computed tomography. Comprehensive database search was conducted to include all the prospective and retrospective studies on blunt trauma patients with altered sensorium undergoing cervical spine multidetector CT scan as core imaging modality to "clear" the cervical spine. The studies used two main gold standards, magnetic resonance imaging of the cervical spine and/or prolonged clinical follow-up. The data was extracted to report true positive, true negatives, false positives and false negatives. Meta-analysis of sensitivity, specificity, negative and positive predictive values was performed using Meta Analyst Beta 3.13 software. We also performed a retrospective investigation comparing a robust clinical follow-up and/or cervical spine MR findings in 53 obtunded blunt trauma patients, who previously had undergone a normal multidetector CT scan of the cervical spine reported by a radiologist. A total of 10 studies involving 1850 obtunded blunt trauma patients with initial cervical spine CT scan reported as normal were included in the final meta-analysis. The cumulative negative predictive value and specificity of cervical spine CT of the ten studies was 99.7% (99.4-99.9%, 95% confidence interval). The positive predictive value and sensitivity was 93.7% (84.0-97.7%, 95% confidence interval). In the retrospective review of our obtunded blunt trauma patients, none was later diagnosed to have significant cervical spine injury that required a change in clinical management. In a blunt trauma patient with altered sensorium, a normal cervical spine CT scan is conclusive to safely rule out a clinically significant cervical spine injury. The results of this meta-analysis strongly support the removal of cervical precautions in obtunded blunt trauma patient after normal cervical spine computed tomography. Any further imaging like magnetic resonance imaging of the cervical spine should be performed on case-to-case basis. Copyright © 2013 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kudoh, Kouichi, E-mail: cdk70770@par.odn.ne.jp; Kadota, Masataka; Nakayama, Yoshiharu
2003-09-15
A girl with continuous urinary incontinence was successfully treated by angiographic embolization of a hypoplastic pelvic kidney with a single unilateral vaginal ectopic opening of the ureter. For this intervention, CT angiography was useful for detecting the corresponding renal artery of the hypoplastic kidney.
Gender Differences of Airway Dimensions in Anatomically Matched Sites on CT in Smokers
Kim, Yu-Il; Schroeder, Joyce; Lynch, David; Newell, John; Make, Barry; Friedlander, Adam; Estépar, Raúl San José; Hanania, Nicola A.; Washko, George; Murphy, James R.; Wilson, Carla; Hokanson, John E.; Zach, Jordan; Butterfield, Kiel; Bowler, Russell P.
2013-01-01
Rationale and Objectives There are limited data on, and controversies regarding gender differences in the airway dimensions of smokers. Multi-detector CT (MDCT) images were analyzed to examine whether gender could explain differences in airway dimensions of anatomically matched airways in smokers. Materials and Methods We used VIDA imaging software to analyze MDCT scans from 2047 smokers (M:F, 1021:1026) from the COPDGene® cohort. The airway dimensions were analyzed from segmental to subsubsegmental bronchi. We compared the differences of luminal area, inner diameter, wall thickness, wall area percentage (WA%) for each airway between men and women, and multiple linear regression including covariates (age, gender, body sizes, and other relevant confounding factors) was used to determine the predictors of each airway dimensions. Results Lumen area, internal diameter and wall thickness were smaller for women than men in all measured airway (18.4 vs 22.5 mm2 for segmental bronchial lumen area, 10.4 vs 12.5 mm2 for subsegmental bronchi, 6.5 vs 7.7 mm2 for subsubsegmental bronchi, respectively p < 0.001). However, women had greater WA% in subsegmental and subsubsegmental bronchi. In multivariate regression, gender remained one of the most significant predictors of WA%, lumen area, inner diameter and wall thickness. Conclusion Women smokers have higher WA%, but lower luminal area, internal diameter and airway thickness in anatomically matched airways as measured by CT scan than do male smokers. This difference may explain, in part, gender differences in the prevalence of COPD and airflow limitation. PMID:21756032
[Sigmoid endometriosis: a diagnostic dilemma on multidetector CT].
Telegrafo, Michele; Lorusso, Valentina; Rubini, Giuseppe; Rella, Leonarda; Pezzolla, Angela; Stabile Ianora, Amato Antonio; Moschetta, Marco
2013-01-01
Intestinal endometriosis represents a common condition that occurs particularly in women of reproductive age. The gastrointestinal tract is the third most common localization of endometriosis, after the ovaries and the peritoneum, and recto-sigmoid tract is involved in 70% of cases. Recto-sigmoid endometriosis has to be differentiated from other diseases of large bowel, especially in patients without a history of endometriosis. We report a case of sigmoid endometriosis which represented a diagnostic dilemma on multidetector computed tomography.
Idriz, Sanjin; Patel, Jaymin H; Ameli Renani, Seyed; Allan, Rosemary; Vlahos, Ioannis
2015-01-01
The use of computed tomography (CT) in clinical practice has been increasing rapidly, with the number of CT examinations performed in adults and children rising by 10% per year in England. Because the radiology community strives to reduce the radiation dose associated with pediatric examinations, external factors, including guidelines for pediatric head injury, are raising expectations for use of cranial CT in the pediatric population. Thus, radiologists are increasingly likely to encounter pediatric head CT examinations in daily practice. The variable appearance of cranial sutures at different ages can be confusing for inexperienced readers of radiologic images. The evolution of multidetector CT with thin-section acquisition increases the clarity of some of these sutures, which may be misinterpreted as fractures. Familiarity with the normal anatomy of the pediatric skull, how it changes with age, and normal variants can assist in translating the increased resolution of multidetector CT into more accurate detection of fractures and confident determination of normality, thereby reducing prolonged hospitalization of children with normal developmental structures that have been misinterpreted as fractures. More important, the potential morbidity and mortality related to false-negative interpretation of fractures as normal sutures may be avoided. The authors describe the normal anatomy of all standard pediatric sutures, common variants, and sutural mimics, thereby providing an accurate and safe framework for CT evaluation of skull trauma in pediatric patients. (©)RSNA, 2015.
Role of multidetector computed tomography in evaluating incidentally detected breast lesions.
Moschetta, Marco; Scardapane, Arnaldo; Lorusso, Valentina; Rella, Leonarda; Telegrafo, Michele; Serio, Gabriella; Angelelli, Giuseppe; Ianora, Amato Antonio Stabile
2015-01-01
Computed tomography (CT) does not represent the primary method for the evaluation of breast lesions; however, it can detect breast abnormalities, even when performed for other reasons related to thoracic structures. The aim of this study is to evaluate the potential benefits of 320-row multidetector CT (MDCT) in evaluating and differentiating incidentally detected breast lesions by using vessel probe and 3D analysis software with net enhancement value. Sixty-two breast lesions in 46 patients who underwent 320-row chest CT examination were retrospectively evaluated. CT scans were assessed searching for the presence, location, number, morphological features, and density of breast nodules. Net enhancement was calculated by subtracting precontrast density from the density obtained by postcontrast values. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of CT were calculated for morphological features and net enhancement. Thirty of 62 lesions were found to be malignant at histological examination and 32 were found to be benign. When morphological features were considered, the sensitivity, specificity, accuracy, PPV, and NPV of CT were 87%, 100%, 88%, 100%, and 50%, respectively. Based on net enhancement, CT reached a sensitivity, specificity, accuracy, PPV, and NPV of 100%, 94%, 97%, 94%, and 100%, respectively. MDCT allows to recognize and characterize breast lesions based on morphological features. Net enhancement can be proposed as an additional accurate feature of CT.
Ozcan, H Nursun; Gormez, Ayşegul; Ozsurekci, Yasemin; Karakaya, Jale; Oguz, Berna; Unal, Sule; Cetin, Mualla; Ceyhan, Mehmet; Haliloglu, Mithat
2017-02-01
Computed tomography (CT) is commonly used to detect pulmonary infection in immunocompromised children. To compare MRI and multidetector CT findings of pulmonary abnormalities in immunocompromised children. Seventeen neutropaenic children (6 girls; ages 2-18 years) were included. Non-contrast-enhanced CT was performed with a 64-detector CT scanner. Axial and coronal non-enhanced thoracic MRI was performed using a 1.5-T scanner within 24 h of the CT examination (true fast imaging with steady-state free precession, fat-saturated T2-weighted turbo spin echo with motion correction, T2-weighted half-Fourier single-shot turbo spin echo [HASTE], fat-saturated T1-weighted spoiled gradient echo). Pulmonary abnormalities (nodules, consolidations, ground glass opacities, atelectasis, pleural effusion and lymph nodes) were evaluated and compared among MRI sequences and between MRI and CT. The relationship between MRI sequences and nodule sizes was examined by chi- square test. Of 256 CT lesions, 207 (81%, 95% confidence interval [CI] 76-85%) were detected at MRI. Of 202 CT-detected nodules, 157 (78%, 95% CI 71-83%) were seen at motion-corrected MRI. Of the 1-5-mm nodules, 69% were detected by motion-corrected T2-weighted MRI and 38% by HASTE MRI. Sensitivity of MRI (both axial fat-saturated T2-weighted turbo spin echo with variable phase encoding directions (BLADE) images and HASTE sequences) to detect pulmonary abnormalities is promising.
Tonolini, Massimo; Ierardi, Anna Maria; Bracchi, Elena; Magistrelli, Paolo; Vella, Adriana; Carrafiello, Gianpaolo
2017-10-01
Despite availability of effective therapies, peptic ulcer disease (PUD) remains a major global disease, resulting from a combination of persistent Helicobacter pylori infection and widespread use of nonsteroidal anti-inflammatory drugs. Albeit endoscopy definitely represents the mainstay diagnostic technique, patients presenting to emergency departments with unexplained abdominal pain generally undergo multidetector CT as an initial investigation. Although superficial ulcers generally remain inconspicuous, careful multiplanar CT interpretation may allow to detect deep ulcers, secondary mural and extraluminal signs of peptic gastroduodenitis, thereby allowing timely endoscopic verification and appropriate treatment. This pictorial essay aims to provide radiologists with an increased familiarity with CT diagnosis of non-perforated PUD, with emphasis on differential diagnosis. Following an overview of current disease epidemiology and complications, it explains the appropriate CT acquisition and interpretation techniques, and reviews with several examples the cross-sectional findings of uncomplicated PUD. Afterwards, the CT features of PUD complications such as ulcer haemorrhage, gastric outlet obstruction, biliary and pancreatic fistulisation are presented. • Gastric and duodenal peptic ulcers are increasingly caused by nonsteroidal anti-inflammatory drugs • Multiplanar CT interpretation allows detecting deep ulcers and secondary signs of gastroduodenitis • CT diagnosis of uncomplicated peptic disease relies on direct and indirect signs • Currently the commonest complication, haemorrhage may be treated with transarterial embolisation • Other uncommon complications include gastric outlet obstruction and biliopancreatic fistulisation.
NASA Astrophysics Data System (ADS)
Mulyadin; Dewang, Syamsir; Abdullah, Bualkar; Tahir, Dahlang
2018-03-01
In this study, the image quality of CT scan using phantom American College of Radiology (ACR) was determined. Scanning multidetector CT is used to know the image quality parameters by using a solid phantom containing four modules and primarily from materials that are equivalent to water. Each module is 4 cm in diameter and 20 cm in diameter. There is white alignment marks painted white to reflect the alignment laser and there are also “HEAD”, “FOOT”, and “TOP” marks on the phantom to help align. This test obtains CT images of each module according to the routine inspection protocol of the head. Acceptance of image quality obtained for determination: CT Number Accuracy (CTN), CT Number Uniformity and Noise, Linearity CT Number, Slice Technique, Low Contrast Resolution and High Contrast Resolution represent image quality parameters. In testing CT Number Accuracy (CTN), CT Uniform number and Noise are in the range of tolerable values allowed. In the test, Linearity CT Number obtained correlation value above 0.99 is the relationship between electron density and CT Number. In a low contrast resolution test, the smallest contrast groups are visible. In contrast, the high resolution is seen up to 7 lp/cm. The quality of GE CT Scan is very high, as all the image quality tests obtained are within the tolerance brackets of values permitted by the Nuclear Power Control Agency (BAPETEN). Image quality test is a way to get very important information about the accuracy of snoring result by using phantom ACR.
Wanner, Matthew R; Karmazyn, Boaz; Fan, Rong
2015-12-01
Hemobilia secondary to gallbladder polyposis is rare in children but has been reported in a few children with metachromatic leukodystrophy. We present a case with preoperative multidetector computed tomography (MDCT) diagnosis of massive hemobilia caused by gallbladder polyposis in a patient with metachromatic leukodystrophy. Our report highlights the importance of both awareness of the association of gallbladder polyposis with other syndromes such as metachromatic leukodystrophy as well as the possibility of this entity presenting with life-threatening bleeding.
Stomach arteriovenous malformation resected by laparoscopy-assisted surgery: A case report.
Hotta, Masahiro; Yamamoto, Kazuhito; Cho, Kazumitsu; Takao, Yoshimune; Fukuoka, Takeshi; Uchida, Eiji
2016-05-01
Arteriovenous malformations of the stomach are an uncommon cause of upper GI bleeding. We report a case of stomach arteriovenous malformation in an 85-year-old Asian man who presented with massive hematemesis. Initial esophagogastroduodenoscopy did not detect this lesion, but contrast multi-detector CT confirmed GI bleeding. Multi-detector CT revealed a mass of blood vessels underlying the submucosa that arose from the right gastroepiploic artery. Repeat esophagogastroduodenoscopy showed that the lesion was a submucosal tumor with erosion and without active bleeding in the lower body of the stomach on the greater curvature. We performed partial gastrectomy via laparoscopy-assisted surgery. The histopathological diagnosis was arteriovenous malformation. © 2016 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.
Zhu, Chengcheng; Patterson, Andrew J; Thomas, Owen M; Sadat, Umar; Graves, Martin J; Gillard, Jonathan H
2013-04-01
Luminal stenosis is used for selecting the optimal management strategy for patients with carotid artery disease. The aim of this study is to evaluate the reproducibility of carotid stenosis quantification using manual and automated segmentation methods using submillimeter through-plane resolution Multi-Detector CT angiography (MDCTA). 35 patients having carotid artery disease with >30 % luminal stenosis as identified by carotid duplex imaging underwent contrast enhanced MDCTA. Two experienced CT readers quantified carotid stenosis from axial source images, reconstructed maximum intensity projection (MIP) and 3D-carotid geometry which was automatically segmented by an open-source toolkit (Vascular Modelling Toolkit, VMTK) using NASCET criteria. Good agreement among the measurement using axial images, MIP and automatic segmentation was observed. Automatic segmentation methods show better inter-observer agreement between the readers (intra-class correlation coefficient (ICC): 0.99 for diameter stenosis measurement) than manual measurement of axial (ICC = 0.82) and MIP (ICC = 0.86) images. Carotid stenosis quantification using an automatic segmentation method has higher reproducibility compared with manual methods.
Tacher, Vania; Duran, Rafael; Lin, MingDe; Sohn, Jae Ho; Sharma, Karun V.; Wang, Zhijun; Chapiro, Julius; Gacchina Johnson, Carmen; Bhagat, Nikhil; Dreher, Matthew R.; Schäfer, Dirk; Woods, David L.; Lewis, Andrew L.; Tang, Yiqing; Grass, Michael; Wood, Bradford J.
2016-01-01
Purpose To assess the visibility of radiopaque microspheres during transarterial embolization (TAE) in the VX2 rabbit liver tumor model by using multimodality imaging, including single-snapshot radiography, cone-beam computed tomography (CT), multidetector CT, and micro-CT. Materials and Methods The study was approved by the institutional animal care and use committee. Fifteen VX2-tumor-bearing rabbits were assigned to three groups depending on the type of embolic agent injected: 70–150-μm radiopaque microspheres in saline (radiopaque microsphere group), 70–150-μm radiopaque microspheres in contrast material (radiopaque microsphere plus contrast material group), and 70–150-μm radiolucent microspheres in contrast material (nonradiopaque microsphere plus contrast material group). Rabbits were imaged with single-snapshot radiography, cone-beam CT, and multidetector CT. Three to 5 weeks after sacrifice, excised livers were imaged with micro-CT and histologic analysis was performed. The visibility of the embolic agent was assessed with all modalities before and after embolization by using a qualitative three-point scale score reading study and a quantitative assessment of the signal-to-noise ratio (SNR) change in various regions of interest, including the tumor and its feeding arteries. The Kruskal-Wallis test was used to compare the rabbit characteristics across groups, and the Wilcoxon signed rank test was used to compare SNR measurements before and after embolization. Results Radiopaque microspheres were qualitatively visualized within tumor feeding arteries and targeted tissue with all imaging modalities (P < .05), and their presence was confirmed with histologic examination. SNRs of radiopaque microsphere deposition increased after TAE on multidetector CT, cone-beam CT, and micro-CT images (P < .05). Similar results were obtained when contrast material was added to radiopaque microspheres, except for additional image attenuation due to tumor enhancement. For the group with nonradiopaque microspheres and contrast material, retained tumoral contrast remained qualitatively visible with all modalities except for micro-CT, which demonstrated soluble contrast material washout over time. Conclusion Radiopaque microspheres were visible with all imaging modalities and helped increase conspicuity of the tumor as well as its feeding arteries after TAE in a rabbit VX2 liver tumor model. © RSNA, 2015 PMID:26678453
Park, Jung Mi; Kim, Il Young; Kim, Sang Won; Lee, Sang Mi; Kim, Hyun Gi; Kim, Shin Young; Shin, Hyung Chul
2013-04-01
The aim of this study was to compare the diagnosability between (18)F-fluorodeoxyglucose (FDG) PET/CT and enhanced multi-detector CT (MDCT) for the detection of liver metastasis (LM) according to the size and location in liver and to evaluate standard maximum standardized uptake values (SUVmax) of all liver metastatic lesions. One hundred two consecutive patients with malignancy who underwent both FDG PET/CT and MDCT for LM evaluation were retrospectively reviewed. Among them, 56 patients with LM were enrolled in this study. LM was confirmed by follow-up imaging studies after at least 6 months or by histopathology. FDG PET/CT and MDCT images were visually analyzed using three-point scale by the consensus of two radiologists and two nuclear medicine physicians. The size and location (central vs. sub-capsular) of the all liver lesions were evaluated using MDCT images. Furthermore, SUVmax of all liver lesions on FDG PET/CT images were calculated. A total of 146 liver lesions were detected by FDG PET/CT and MDCT and 142 of the lesions were diagnosed as LM. The detection rates of MDCT and FDG PET/CT for LM by visual analysis were 77 and 78%, respectively. There was no significant difference of detection rate according to the overall location and size of the lesions. However, FDG PET/CT was more sensitive than MDCT for detecting small and sub-capsular LM. The detection rate of FDG PET/CT for LM was 68% by the cutoff SUVmax of 2.7. Although the diagnosabilities of MDCT and FDG PET/CT for detecting LM were comparable, FDG PET/CT is superior to MDCT for detecting small LM located in the sub-capsular portion of liver.
Taylor, Stuart A; Halligan, Steve; Bartram, Clive I; Morgan, Paul R; Talbot, Ian C; Fry, Nicola; Saunders, Brian P; Khosraviani, Kirosh; Atkin, Wendy
2003-10-01
To investigate the effects of orientation, collimation, pitch, and tube current setting on polyp detection at multi-detector row computed tomographic (CT) colonography and to determine the optimal combination of scanning parameters for screening. A colectomy specimen containing 117 polyps of different sizes was insufflated and imaged with a multi-detector row CT scanner at various collimation (1.25 and 2.5 mm), pitch (3 and 6), and tube current (50, 100, and 150 mA) settings. Two-dimensional multiplanar reformatted images and three-dimensional endoluminal surface renderings from the 12 resultant data sets were examined by one observer for the presence and conspicuity of polyps. The results were analyzed with Poisson regression and logistic regression to determine the effects of scanning parameters and of specimen orientation on polyp detection. The percentage of polyps that were detected significantly increased when collimation (P =.008) and table feed (P =.03) were decreased. Increased tube current resulted in improved detection only of polyps with a diameter of less than 5 mm. Polyps of less than 5 mm were optimally depicted with a collimation of 1.25 mm, a pitch of 3, and a tube current setting of 150 mA; polyps with a diameter greater than 5 mm were adequately depicted with 1.25-mm collimation and with either pitch setting and any of the three tube current settings. Small polyps in the transverse segment (positioned at a 90 degrees angle to the z axis of scanning) were significantly less visible than those in parallel or oblique orientations (P <.001). The effective radiation dose, calculated with a Monte Carlo simulation, was 1.4-10.0 mSv. Detection of small polyps (<5 mm) with multi-detector row CT is highly dependent on collimation, pitch, and, to a lesser extent, tube current. Collimation of 1.25 mm, combined with pitch of 6 and tube current of 50 mA, provides for reliable detection of polyps 5 mm or larger while limiting the effective radiation dose. Polyps smaller than 5 mm, however, may be poorly depicted with use of these settings in the transverse colon. Copyright RSNA, 2003
Petrović, Kosta; Turkalj, Ivan; Stojanović, Sanja; Vucaj-Cirilović, Viktorija; Nikolić, Olivera; Stojiljković, Dragana
2013-08-01
Computerized tomography (CT), especially multidetector CT (MDCT), has had a revolutionary impact in diagnostic in traumatized patients. The aim of the study was to identify and compare the frequency of injuries to bone structures of the thorax displayed with 5-mm-thick axial CT slices and thin-slice (MDCT) examination with the use of 3D reconstructions, primarily multiplanar reformations (MPR). This prospective study included 61 patients with blunt trauma submitted to CT scan of the thorax as initial assessment. The two experienced radiologists inde pendently and separately described the findings for 5-mm-thick axial CT slices (5 mm CT) as in monoslice CT examination; MPR and other 3D reconstructions along with thin-slice axial sections which were available in modern MDCT technologies. After describing thin-slice examination in case of disagreement in the findings, the examiners redescribed thin-slice examination together which was ultimately considered as a real, true finding. No statistically significant difference in interobserver evaluation of 5 mm CT examination was recorded (p > 0.05). Evaluation of fractures of sternum with 5 mm CT and MDCT showed a statistically significant difference (p < 0.05) in favor of better display of injury by MDCT examination. MDCT is a powerful diagnostic tool that can describe higher number of bone fractures of the chest in traumatized patients compared to 5 mm CT, especially in the region of sternum for which a statistical significance was obtained using MPR. Moreover, the importance of MDCT is also set by easier and more accurate determination of the level of bone injury.
Cardiac Computed Tomography (Multidetector CT, or MDCT)
... other tests, such as chest X-rays , electrocardiograms (ECG) , echocardiograms (echocardiography) , or stress tests , don’t give ... be attached to your chest to monitor your ECG. The ECG is also needed to help the ...
Casula, E; Lonjedo, E; Cerverón, M J; Ruiz, A; Gómez, J
2014-01-01
The increase in the frequency of abdominal aortic aneurysms (AAA) and the widely accepted use of endovascular aneurysm repair (EVAR) as a first-line treatment or as an alternative to conventional surgery make it necessary for radiologists to have thorough knowledge of the pre- and post-treatment findings. The high image quality provided by multidetector computed tomography (MDCT) enables CT angiography to play a fundamental role in the study of AAA and in planning treatment. The objective of this article is to review the cases of AAA in which CT angiography was the main imaging technique, so that radiologists will be able to detect the signs related to this disease, to diagnose it, to plan treatment, and to detect complications in the postoperative period. Copyright © 2012 SERAM. Published by Elsevier Espana. All rights reserved.
Lell, M M; May, M S; Brand, M; Eller, A; Buder, T; Hofmann, E; Uder, M; Wuest, W
2015-07-01
CT is the imaging technique of choice in the evaluation of midface trauma or inflammatory disease. We performed a systematic evaluation of scan protocols to optimize image quality and radiation exposure on third-generation dual-source CT. CT protocols with different tube voltage (70-150 kV), current (25-300 reference mAs), prefiltration, pitch value, and rotation time were systematically evaluated. All images were reconstructed with iterative reconstruction (Advanced Modeled Iterative Reconstruction, level 2). To individually compare results with otherwise identical factors, we obtained all scans on a frozen human head. Conebeam CT was performed for image quality and dose comparison with multidetector row CT. Delineation of important anatomic structures and incidental pathologic conditions in the cadaver head was evaluated. One hundred kilovolts with tin prefiltration demonstrated the best compromise between dose and image quality. The most dose-effective combination for trauma imaging was Sn100 kV/250 mAs (volume CT dose index, 2.02 mGy), and for preoperative sinus surgery planning, Sn100 kV/150 mAs (volume CT dose index, 1.22 mGy). "Sn" indicates an additional prefiltration of the x-ray beam with a tin filter to constrict the energy spectrum. Exclusion of sinonasal disease was possible with even a lower dose by using Sn100 kV/25 mAs (volume CT dose index, 0.2 mGy). High image quality at very low dose levels can be achieved by using a Sn100-kV protocol with iterative reconstruction. The effective dose is comparable with that of conventional radiography, and the high image quality at even lower radiation exposure favors multidetector row CT over conebeam CT. © 2015 by American Journal of Neuroradiology.
Tung, Matthew K; Cameron, James D; Casan, Joshua M; Crossett, Marcus; Troupis, John M; Meredith, Ian T; Seneviratne, Sujith K
2013-01-01
Minimization of radiation exposure remains an important subject that occurs in parallel with advances in scanner technology. We report our experience of evolving radiation dose and its determinants after the introduction of 320-multidetector row cardiac CT within a single tertiary cardiology referral service. Four cohorts of consecutive patients (total 525 scans), who underwent cardiac CT at defined time points as early as 2008, are described. These include a cohort just after scanner installation, after 2 upgrades of the operating system, and after introduction of an adaptive iterative image reconstruction algorithm. The proportions of nondiagnostic coronary artery segments and studies with nondiagnostic segments were compared between cohorts. Significant reductions were observed in median radiation doses in all cohorts compared with the initial cohort (P < .001). Median dose-length product fell from 944 mGy · cm (interquartile range [IQR], 567.3-1426.5 mGy · cm) to 156 mGy · cm (IQR, 99.2-265.0 mGy · cm). Although the proportion of prospectively triggered scans has increased, reductions in radiation dose have occurred independently of distribution of scan formats. In multiple regression that combined all groups, determinants of dose-length product were tube output, the number of cardiac cycles scanned, tube voltage, scan length, scan format, body mass index, phase width, and heart rate (adjusted R(2) = 0.85, P < .001). The proportion of nondiagnostic coronary artery segments was slightly increased in group 4 (2.9%; P < .01). While maintaining diagnostic quality in 320-multidetector row cardiac CT, the radiation dose has decreased substantially because of a combination of dose-reduction protocols and technical improvements. Continued minimization of radiation dose will increase the potential for cardiac CT to expand as a cardiac imaging modality. Copyright © 2013 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.
Elucidating early CT after pancreatico-duodenectomy: a primer for radiologists.
Tonolini, Massimo; Ierardi, Anna Maria; Carrafiello, Gianpaolo
2018-04-13
Pancreatico-duodenectomy (PD) represents the standard surgical treatment for resectable malignancies of the pancreatic head, distal common bile duct, periampullary region and duodenum, and is also performed to manage selected benign tumours and refractory chronic pancreatitis. Despite improved surgical techniques and acceptable mortality, PD remains a technically demanding, high-risk operation burdened with high morbidity (complication rates 40-50% of patients). Multidetector computed tomography (CT) represents the mainstay modality to rapidly investigate the postoperative abdomen, and to provide a consistent basis for an appropriate choice between conservative, interventional or surgical treatment. However, radiologists require familiarity with the surgically altered anatomy, awareness of expected imaging appearances and possible complications to correctly interpret early post-PD CT studies. This paper provides an overview of surgical indications and techniques, discusses risk factors and clinical manifestations of the usual postsurgical complications, and suggests appropriate techniques and indications for early postoperative CT imaging. Afterwards, the usual, normal early post-PD CT findings are presented, including transient fluid, pneumobilia, delayed gastric emptying, identification of pancreatic gland remnant and of surgical anastomoses. Finally, several imaging examples review the most common and some unusual complications such as pancreatic fistula, bile leaks, abscesses, intraluminal and extraluminal haemorrhage, and acute pancreatitis. • Pancreatico-duodenectomy (PD) is a technically demanding surgery burdened with high morbidity (40-50%). • Multidetector CT is the mainstay technique to investigate suspected complications following PD. • Interpreting post-PD CT requires knowledge of surgically altered anatomy and expected findings. • CT showing collection at surgical site supports clinico-biological diagnosis of pancreatic fistula. • Other complications include biliary leaks, haemorrhage, abscesses and venous thrombosis.
Facenda, Catherine; Vaz, Nuno; Castañeda, Edgar Augusto; del Amo, Montserrat; Garcia-Diez, Ana Isabel; Pomes, Jaime
2017-01-01
Blunt injuries to the chest wall are an important chapter on emergency room (ER) departments, being the third most common injuries in trauma patients which ominous complications could appear. This article describes different types of traumatic events affecting the chest wall, which maybe misdiagnosed with conventional X-ray. Special emphasis has been done in computed tomography (CT) and multidetector CT (MDCT) imaging. This technique is considered the “gold-standard” for those traumatic patients, due to its fast acquisition covering the whole area of interest in axial plane, reconstructing multiplanar (2D, 3D) volume-rendered images with a superb quality and angiographic CT capabilities for evaluating vascular damage. Complementary techniques such as ultrasonography (US) and magnetic resonance imaging (MRI) may improve the diagnostic accuracy due to its great capacity in visualising soft-tissue trauma (muscle-tendinous tears) and subtle fractures. All these imaging methods have an important role in quantifying the severity of chest wall trauma. The findings of this study have been exposed with cases of our archives in a didactic way. PMID:28932697
Imaging of patent foramen ovale with 64-section multidetector CT.
Saremi, Farhood; Channual, Stephanie; Raney, Aidan; Gurudevan, Swaminatha V; Narula, Jagat; Fowler, Steven; Abolhoda, Amir; Milliken, Jeffrey C
2008-11-01
To investigate the feasibility of 64-section multidetector computed tomography (CT) by using CT angiography (a) to demonstrate anatomic detail of the interatrial septum pertinent to the patent foramen ovale (PFO), and (b) to visually detect left-to-right PFO shunts and compare these findings in patients who also underwent transesophageal echocardiography (TEE). In this institutional review board-approved HIPAA-compliant study, electrocardiographically gated coronary CT angiograms in 264 patients (159 men, 105 women; mean age, 60 years) were reviewed for PFO morphologic features. The length and diameter of the opening of the PFO tunnel, presence of atrial septal aneurysm (ASA), and PFO shunts were evaluated. A left-to-right shunt was assigned a grade according to length of contrast agent jet (grade 1,
López-Ramírez, M A; Lever-Rosas, C D; Motta-Ramírez, G A; Rebollo-Hurtado, V; Guzmán-Bárcenas, J; Fonseca-Morales, J V; Carreño-Lomeli, M A
In relation to the number of new cases diagnosed, gastric cancer is the fourth most common cancer worldwide, and the second cause of cancer death. The development of multidetector tomography has improved the preoperative staging of gastric cancer. To correlate preoperative tomographic studies with the definitive pathologic results according to the TNM staging system. A retrospective, cross-sectional study within the time frame of January 2009 to December 2013 was conducted that included the case records of 67 patients. They all had upper endoscopy and preoperative multidetector tomography examinations, underwent surgical resection, and had the corresponding histopathology study. Statistical analysis was carried out with the SPSS version 15.0 software and the sensitivity and specificity calculations were made using the Excel 2011 program for Mac. The majority of the patients included in the case series had clinical stage iii and iv disease. When compared with the histopathologic result, the overall accuracy of multidetector CT was 83% (T0 96%, T1 94%, T2 93%, T3 67%, and T4 67%) for tumor size (T) and was 70% (N0 72%, N1 73%, N2 70%, and N3 66%) for lymph node involvement (N). Overall sensitivity was 48% (T0 100%, T1 0%, T2 33%, T3 44%, and T4 65%) for T and was 41% (N0 58%, N1 56%, N2 15%, and N3 35%) for N. A strong association between the multidetector CT results and the pathology results was demonstrated through the Spearman's correlation, especially in T4 and N3. Multidetector computed tomography showed greater congruency in detecting stages T4, N0, and N3 in gastric cancer, when compared with the definitive histopathologic results. Copyright © 2017 Asociación Mexicana de Gastroenterología. Publicado por Masson Doyma México S.A. All rights reserved.
Penetrating Colorectal Injuries: Diagnostic Performance of Multidetector CT with Trajectography.
Dreizin, David; Boscak, Alexis R; Anstadt, Michael J; Tirada, Nikki; Chiu, William C; Munera, Felipe; Bodanapally, Uttam K; Hornick, Michael; Stein, Deborah M
2016-12-01
Purpose To determine the diagnostic performance of multidetector computed tomography (CT) with trajectography for penetrating colorectal injuries. Materials and Methods This institutional review board-approved and HIPAA-compliant study was a 6-year blinded retrospective review by two independent readers of 182 consecutive patients who preoperatively underwent 40- or 64-row multidetector CT for penetrating torso trauma below the diaphragm and had surgically confirmed findings. Colorectal perforation was present in 42 patients. Trajectory analysis with postprocessing software was used for all studies. Additional signs evaluated were rectal contrast agent leak, collections of extruded fecal material, mural defect, wall thickening, abnormal enhancement, free fluid or stranding, and free air. The quality of the colorectal contrast agent administration was recorded. Sensitivity, specificity, predictive values, areas under the receiver operating characteristic curves (AUCs), and Cohen κ were determined. Results In patients with rectal contrast agent administration (n = 151), AUCs were 0.90-0.91, which indicated excellent accuracy. Trajectory was sensitive (88%-91%). For single wounds (n = 104), sensitivity of trajectory was 96% for both readers, but was only 80% for multiple wounds (n = 47). Contrast agent leak was highly specific (96%-98%), but insensitive (42%-46%). Improved diagnostic performance was observed in patients with poor colonic distension or opacification. Accuracy remained high (AUC, 0.86-0.99) in the group without rectal contrast agent administration (n = 31). Conclusion Trajectory had excellent sensitivity, while rectal contrast agent leak was specific but insensitive. Sensitivity of trajectory was lower for multiple wounds. Accuracy remained high in patients without rectal contrast agent administration. © RSNA, 2016.
Basak, Muzaffer; Ozkurt, Huseyin; Tanriverdi, Orhan; Cay, Esra; Aydin, Mustafa; Miroglu, Cengiz
2009-01-01
The purpose of this study was to evaluate the use of virtual cystoscopy performed with multidetector computed tomography (CT) in patients with suspected bladder tumors and histories of bladder carcinoma operation. Thirty-six patients (29 men and 7 women) with a mean age of 66 years (range, 24-88 years) with suspected bladder tumors and histories of bladder carcinoma operation were included in this prospective study. Virtual cystoscopy was performed by 16-slice multidetector CT scanner. The bladder was filled with diluted contrast material solution through a Foley catheter. Then, all patients underwent conventional cystoscopy examination. Two reviewers found 18 lesions detected by virtual cystoscopy by consensus, whereas 19 lesions were depicted by conventional cystoscopy. At virtual and conventional cystoscopies, the conditions of 3 patients, 2 with chronic inflammations and 1 with foreign body reaction, were wrongly diagnosed as tumors. At conventional cystoscopy, one patient's result was wrongly interpreted as normal. In pathologic evaluation, all tumors were diagnosed as transitional cell carcinoma. Bladder tumor can be noninvasively diagnosed using virtual cystoscopy. Use of virtual cystoscopy should be considered inpatients who present with hematuria or have histories of bladder carcinoma operation and are for follow-up because of its lesser complication risk and its being a less invasive, easily applied procedure without need of anesthesia. In the future, owing to the development of the CT technology and image processing technique, virtual cystoscopy may have a part in the detection of bladder cancer.
NASA Astrophysics Data System (ADS)
Tarasov, A. P.; Egorov, A. I.; Rogatkin, D. A.
2017-07-01
Using multidetector computed tomography, thicknesses of bone squame and soft tissues of human head were assessed. MC simulation revealed impropriety of source-detector separation distances for 3 oximeters, which can cause extracerebral contamination.
Lin, Yuning; Chen, Ziqian; Yang, Xizhang; Zhong, Qun; Zhang, Hongwen; Yang, Li; Xu, Shangwen; Li, Hui
2013-12-01
The aim of this study is to evaluate the diagnostic performance of multidetector CT angiography (CTA) in depicting bronchial and non-bronchial systemic arteries in patients with haemoptysis and to assess whether this modality helps determine the feasibility of angiographic embolisation. Fifty-two patients with haemoptysis between January 2010 and July 2011 underwent both preoperative multidetector CTA and digital subtraction angiography (DSA) imaging. Diagnostic performance of CTA in depicting arteries causing haemoptysis was assessed on a per-patient and a per-artery basis. The feasibility of the endovascular treatment evaluated by CTA was analysed. Sensitivity, specificity, and positive and negative predictive values for those analyses were determined. Fifty patients were included in the artery-presence-number analysis. In the per-patient analysis, neither CTA (P = 0.25) nor DSA (P = 1.00) showed statistical difference in the detection of arteries causing haemoptysis. The sensitivity, specificity, and positive and negative predictive values were 94%, 100%, 100%, and 40%, respectively, for the presence of pathologic arteries evaluated by CTA, and 98%, 100%, 100%, and 67%, respectively, for DSA. On the per-artery basis, CTA correctly identified 97% (107/110). Fifty-two patients were included in the feasibility analysis. The performance of CTA in predicting the feasibility of angiographic embolisation was not statistically different from the treatment performed (P = 1.00). The sensitivity, specificity, and positive and negative predictive values were 96%, 80%, 98% and 67%, respectively, for CTA. Multidetector CTA is an accurate imaging method in depicting the presence and number of arteries causing haemoptysis. This modality is also useful for determining the feasibility of angiographic embolisation for haemoptysis. © 2013 The Authors. Journal of Medical Imaging and Radiation Oncology © 2013 The Royal Australian and New Zealand College of Radiologists.
Pulmonary involvement in rheumatoid arthritis: multidetector computed tomography findings.
Yuksekkaya, Ruken; Celikyay, Fatih; Yilmaz, Ayse; Arslan, Sule; Inanir, Ahmet; Inonu, Handan; Deniz, Caglar
2013-12-01
Pulmonary involvement in rheumatoid arthritis (RA) is common and encompasses a large spectrum of disease with different treatment options and prognoses. Therefore, assessment of these patients with multidetector computed tomography (MDCT) is vital. To evaluate the MDCT pulmonary findings of patients with RA and to compare these findings with the clinical status. Chest MDCT scans of 85 patients with RA between 2006-2012 were assessed. One patient with a pulmonary infection was excluded from the study. MDCT findings and distribution of the CT findings were examined, and patients were classified according to the predominant CT pattern. The pulmonary function test (PFT) results and categories, demographic characteristics, and clinical status of some of the patients for whom the results were obtained were evaluated, and the CT findings, PFT results, demographic characteristics, and clinical status were compared. The study group consisted of 20 men (mean age, 58.1 years ± 13.1; range, 15-77 years) and 64 women (mean age, 55.3 years ± 11.5; range, 30-84 years). The most frequent findings were nodules (78.6%) and pleural thickening (48.8%). The most common CT patterns were follicular bronchiolitis (FB) in 28 (33.3%) patients and nodular disease (ND) in 12 (14.3%) others. There was no statistically significant difference between the CT findings and PFT results, and no statistically significant difference was noted in the CT findings between symptomatic and asymptomatic patients. In addition, there were some patients who exhibited no symptoms and/or had abnormal PFT results but had abnormal CT findings. Rheumatoid arthritis is associated with a high frequency of CT findings and CT patterns, with nodules and pleural thickening being the most common CT findings and FB and ND being the most common CT patterns. MDCT identification of patients with RA may be helpful in the evaluation of pulmonary disease, even in patients without symptoms and PFT abnormalities.
Takahashi, Shigekiyo; Kawasaki, Masanori; Miyata, Shusaku; Suzuki, Keita; Yamaura, Makoto; Ido, Takahisa; Aoyama, Takuma; Fujiwara, Hisayoshi; Minatoguchi, Shinya
2016-01-01
Recently, a new generation of multi-detector row computed tomography (CT) with 320-detector rows (DR) has become available in the clinical settings. The purpose of the present study was to determine the cutoff values of Hounsfield unit (HU) for discrimination of plaque components by comparing HU of coronary plaques with integrated backscatter intravascular ultrasound (IB-IVUS) serving as a gold standard. Seventy-seven coronary atherosclerotic lesions in 77 patients with angina were visualized by both 320-DR CT (Aquilion One, Toshiba, Japan) and IB-IVUS at the same site. To determine the thresholds for discrimination of plaque components, we compared HU with IB values as a gold standard. Optimal thresholds were determined from receiver operating characteristic (ROC) curves analysis. The HU values of lipid pool (n = 115), fibrosis (n = 93), vessel lumen and calcification (n = 73) were 28 ± 19 HU (range -18 to 69 HU), 98 ± 31 HU (44 to 195 HU), 357 ± 65 HU (227 to 534 HU) and 998 ± 236 HU (366 to 1,489 HU), respectively. The thresholds of 56 HU, 210 HU and 490 HU were the most reliable predictors of lipid pool, fibrosis, vessel lumen and calcification, respectively. Lipid volume measured by 320-DR CT was correlated with that measured by IB-IVUS (r = 0.63, p < 0.05), whereas fibrous volume measured by 320-DR CT was not. Lipid volume measured by 320-DR CT was correlated with that measured by IB-IVUS, whereas fibrous volume was not correlated with that measured by IB-IVUS because manual exclusion of the outside of vessel hindered rigorous discrimination between fibrosis and extravascular components.
Akhilesh, Philomina; Kulkarni, Arti R; Jamhale, Shramika H; Sharma, S D; Kumar, Rajesh; Datta, D
2017-04-25
The purpose of this study was to estimate eye lens dose during brain scans in 16-, 64-, 128- and 256-slice multidetector computed tomography (CT) scanners in helical acquisition mode and to test the feasibility of using radiochromic film as eye lens dosemeter during CT scanning. Eye lens dose measurements were performed using Gafchromic XR-QA2 film on a polystyrene head phantom designed with outer dimensions equivalent to the head size of a reference Indian man. The response accuracy of XR-QA2 film was validated by using thermoluminescence dosemeters. The eye lens dose measured using XR-QA2 film on head phantom for plain brain scanning in helical mode ranged from 43.8 to 45.8 mGy. The XR-QA2 film measured dose values were in agreement with TLD measured dose values within a maximum variation of 8.9%. The good correlation between the two data sets confirms the viability of using XR-QA2 film for eye lens dosimetry. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Ueda, Tomohiro; Teshima, Hideki; Fukunaga, Shuji; Aoyagi, Shigeaki; Tanaka, Hiroyuki
2013-01-01
This study was performed to evaluate the diagnostic role of electrocardiographically gated multidetector-row computed tomography (MDCT) for prosthetic valve obstruction (PVO) in the aortic position. Between 2002 and 2006, 9 patients were diagnosed with PVO of an aortic bileaflet mechanical valve based on echocardiographic and cineradiographic criteria. These 9 patients were examined using MDCT before replacement of the mechanical valve, and intraoperative findings were compared to morphologic periprosthetic abnormalities observed on MDCT. CT attenuation (Hounsfield units; HU) of the periprosthetic abnormalities was measured to investigate the underlying cause of the PVO. MDCT showed subprosthetic masses extending beyond the prosthetic ring into the orifice of the valve. At reoperation, presence of subprosthetic pannus was confirmed in all of the 9 patients, but no periprosthetic thrombus was found. The mean CT attenuation of the subprosthetic pannus was 170 HU, and it was significantly greater than that obtained from the interventricular septum (108 HU; P<0.0001). MDCT can be used to clearly visualize subprosthetic pannus causing PVO and the mean CT attenuation of subprosthetic pannus is significantly higher than that of the interventricular septum on MDCT.
Yi, Ji Sook; Han, Jong Kyu; Kim, Hyun-Joo
2015-01-01
Objective To assess inter-modality variability when evaluating cervical intervertebral disc herniation using 64-slice multidetector-row computed tomography (MDCT) and magnetic resonance imaging (MRI). Materials and Methods Three musculoskeletal radiologists independently reviewed cervical spine 1.5-T MRI and 64-slice MDCT data on C2-3 though C6-7 of 51 patients in the context of intervertebral disc herniation. Interobserver and inter-modality agreements were expressed as unweighted kappa values. Weighted kappa statistics were used to assess the extents of agreement in terms of the number of involved segments (NIS) in disc herniation and epicenter measurements collected using MDCT and MRI. Results The interobserver agreement rates upon evaluation of disc morphology by the three radiologists were in fair to moderate agreement (k = 0.39-0.53 for MDCT images; k = 0.45-0.56 for MRIs). When the disc morphology was categorized into two and four grades, the inter-modality agreement rates were moderate (k-value, 0.59) and substantial (k-value, 0.66), respectively. The inter-modality agreements for evaluations of the NIS (k-value, 0.78) and the epicenter (k-value, 0.79) were substantial. Also, the interobserver agreements for the NIS (CT; k-value, 0.85 and MRI; k-value, 0.88) and epicenter (CT; k-value, 0.74 and MRI; k-value, 0.70) evaluations by two readers were substantial. MDCT tended to underestimate the extent of herniated disc lesions compared with MRI. Conclusion Multidetector-row computed tomography and MRI showed a moderate-to-substantial degree of inter-modality agreement for the assessment of herniated cervical discs. MDCT images have a tendency to underestimate the anterior/posterior extent of the herniated disc compared with MRI. PMID:26175589
Tan, J S P; Tan, K-L; Lee, J C L; Wan, C-M; Leong, J-L; Chan, L-L
2009-02-01
To our knowledge, there has been no study that compares the radiation dose delivered to the eye lens by 16- and 64-section multidetector CT (MDCT) for standard clinical neuroimaging protocols. Our aim was to assess radiation-dose differences between 16- and 64-section MDCT from the same manufacturer, by using near-identical neuroimaging protocols. Three cadaveric heads were scanned on 16- and 64-section MDCT by using standard neuroimaging CT protocols. Eye lens dose was measured by using thermoluminescent dosimeters (TLD), and each scanning was repeated to reduce random error. The dose-length product, volume CT dose index (CTDI(vol)), and TLD readings for each imaging protocol were averaged and compared between scanners and protocols, by using the paired Student t test. Statistical significance was defined at P < .05. The radiation dose delivered and eye lens doses were lower by 28.1%-45.7% (P < .000) on the 64-section MDCT for near-identical imaging protocols. On the 16-section MDCT, lens dose reduction was greatest (81.1%) on a tilted axial mode, compared with a nontilted helical mode for CT brain scans. Among the protocols studied, CT of the temporal bone delivered the greatest radiation dose to the eye lens. Eye lens radiation doses delivered by the 64-section MDCT are significantly lower, partly due to improvements in automatic tube current modulation technology. However, where applicable, protection of the eyes from the radiation beam by either repositioning the head or tilting the gantry remains the best way to reduce eye lens dose.
Cho, S H; Sung, Y M; Kim, M S
2012-10-01
The objective of this study was to review the prevalence and radiological features of rib fractures missed on initial chest CT evaluation, and to examine the diagnostic value of additional coronal images in a large series of trauma patients. 130 patients who presented to an emergency room for blunt chest trauma underwent multidetector row CT of the thorax within the first hour during their stay, and had follow-up CT or bone scans as diagnostic gold standards. Images were evaluated on two separate occasions: once with axial images and once with both axial and coronal images. The detection rates of missed rib fractures were compared between readings using a non-parametric method of clustered data. In the cases of missed rib fractures, the shapes, locations and associated fractures were evaluated. 58 rib fractures were missed with axial images only and 52 were missed with both axial and coronal images (p=0.088). The most common shape of missed rib fractures was buckled (56.9%), and the anterior arc (55.2%) was most commonly involved. 21 (36.2%) missed rib fractures had combined fractures on the same ribs, and 38 (65.5%) were accompanied by fracture on neighbouring ribs. Missed rib fractures are not uncommon, and radiologists should be familiar with buckle fractures, which are frequently missed. Additional coronal imagescan be helpful in the diagnosis of rib fractures that are not seen on axial images.
Controversies in imaging of hepatocellular carcinoma: multidetector CT (MDCT)
Silverman, Paul M; Szklaruk, Janio
2005-01-01
Primary hepatocellular carcinoma (HCC) is a significant tumor worldwide and represents the most common primary hepatic neoplasm. Staging criteria are important for appreciation of timely work up of these neoplasms in contradiction with surgical colleagues. This article demonstrates the appearance of HCC on multiphasic, multidetector CT (MDCT) and relates these findings to current staging criteria. The variable appearance on different planes of contrast is critical to appreciate in staging this neoplasm. The hypervascular nature of the primary tumor makes MDCT and three-phase imaging a critical feature in the detection and characterization of this tumor. This is especially critical in the patients who are candidates for surgical resection. Additionally, MDCT has allowed arterial phase imaging to define the vascular supply of the tumor. An accurate representation of the size and number of lesions is critical in not only the initial staging but also the follow-up of hepatocellular carcinoma. The post-treatment features including the appearance post-surgically and after radiofrequency ablation can be well appreciated on MDCT. PMID:16361147
Evaluation of organ doses in CT examinations with an infant anthropomorphic phantom.
Fujii, K; Akahane, K; Miyazaki, O; Horiuchi, T; Shimada, A; Nagmatsu, H; Yamauchi, M; Yamauchi-Kawaura, C; Kawasaki, T
2011-09-01
The aim of this study is to evaluate organ doses in infant CT examinations with multi-detector row CT scanners. Radiation doses were measured with radiophotoluminescence glass dosemeters set in various organ positions within a 1-y-old child anthropomorphic phantom and organ doses were evaluated from the measurement values. Doses for tissues or organs within the scan range were 28-36 mGy in an infant head CT, 3-11 mGy in a chest CT, 5-11 mGy in an abdominal-pelvic CT and 2-14 mGy in a cardiac CT. The doses varied by the differences in the types of CT scanners and scan parameters used at each medical facility. Compared with those for children of various ages, the doses in an infant CT protocol were found to be similar to or slightly smaller than those in a paediatric CT for 5- or 6-y-old children.
Foster, Allison; Morandi, Federica; May, Elizabeth
2015-01-01
Previous reports describing the prevalence of ear diseases in dogs have primarily been based on dogs presenting with clinical signs of disease. The prevalence of subclinical ear disease remains unknown. The purpose of this cross-sectional retrospective study was to describe the prevalence of lesions consistent with middle and external ear disease in dogs presented for multidetector computed tomography (CT) of the head and/or cranial cervical spine at our hospital during the period of July 2011 and August 2013. For each included dog, data recorded were signalment, CT findings, diagnosis, and treatment. A total of 199 dogs met inclusion criteria. Nineteen dogs (9.5%) were referred for evaluation of suspected ear disease and 27 dogs (13.5%) had histories or physical examination findings consistent with otitis externa. A total of 163 dogs (81.9%) had CT lesions consistent with external ear disease (i.e. ear canal mineralization, external canal thickening, and/or narrowing of the external canal). Thirty-nine dogs (19.5%) had CT lesions consistent with middle ear disease (i.e. soft tissue attenuating/fluid material in the tympanic bullae, bulla wall thickening or lysis, and/or periosteal proliferation of the temporal bone). Findings from this study indicated that the prevalence of external and middle ear disease in dogs could be higher than that previously reported. © 2014 American College of Veterinary Radiology.
Torimitsu, Suguru; Makino, Yohsuke; Saitoh, Hisako; Sakuma, Ayaka; Ishii, Namiko; Yajima, Daisuke; Inokuchi, Go; Motomura, Ayumi; Chiba, Fumiko; Yamaguchi, Rutsuko; Hashimoto, Mari; Hoshioka, Yumi; Iwase, Hirotaro
2015-12-01
Sex estimation of decomposed or skeletal remains is clearly important in forensic contexts. Recently, contemporary population-specific data has been obtained using multidetector computed tomography (MDCT) scanning. The main purpose of this study was to investigate skeletal pelvic dimorphism in a contemporary Japanese forensic sample and to quantify the accuracy of sex estimation using various pelvic measurements obtained from three-dimensional (3D) CT images. This study used a total of 208 cadavers (104 males, 104 females) of which postmortem CT scanning and subsequent forensic autopsy were conducted between December 2011 and August 2014. Eleven measurements of each pelvis were obtained from 3D CT reconstructed images that extracted only bone data. The measurements were analyzed using descriptive statistics and discriminant function analyses. All except one measurement were dimorphic in terms of sex differences. Univariate discriminant function analyses using these measurements provided sex classification accuracy rates of 62.0-98.1%. The subpubic angle was found to contribute most significantly to accurate sex estimation. Multivariate discriminant functions yielded sex prediction accuracy rates of 63.9-98.1%. In conclusion, the pelvic measurements obtained from 3D CT images of a contemporary Japanese population successfully demonstrated sexual dimorphism and may be useful for the estimation of skeletal sex in the field of forensic anthropology. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Dagvasumberel, Munkhbaatar; Shimabukuro, Michio; Nishiuchi, Takeshi; Ueno, Junji; Takao, Shoichiro; Fukuda, Daiju; Hirata, Yoichiro; Kurobe, Hirotsugu; Soeki, Takeshi; Iwase, Takashi; Kusunose, Kenya; Niki, Toshiyuki; Yamaguchi, Koji; Taketani, Yoshio; Yagi, Shusuke; Tomita, Noriko; Yamada, Hirotsugu; Wakatsuki, Tetsuzo; Harada, Masafumi; Kitagawa, Tetsuya; Sata, Masataka
2012-09-10
Growing evidence suggests that epicardial adipose tissue (EAT) may contribute to the development of coronary artery disease (CAD). In this study, we explored gender disparities in EAT volume (EATV) and its impact on coronary atherosclerosis. The study population consisted of 90 consecutive subjects (age: 63 ± 12 years; men: 47, women: 43) who underwent 256-slice multi-detector computed tomography (MDCT) coronary angiography. EATV was measured as the sum of cross-sectional epicardial fat area on CT images, from the lower surface of the left pulmonary artery origin to the apex. Subjects were segregated into the CAD group (coronary luminal narrowing > 50%) and non-CAD group. EATV/body surface area (BSA) was higher among men in the CAD group than in the non-CAD group (62 ± 13 vs. 33 ± 10 cm3/m2, p < 0.0001), but did not differ significantly among women in the 2 groups (49 ± 18 vs. 42 ± 9 cm3/m2, not significant). Multivariate logistic analysis showed that EATV/BSA was the single predictor for >50% coronary luminal narrowing in men (p < 0.0001). Predictors excluded were age, body mass index, hypertension, diabetes mellitus, and hyperlipidemia. Increased EATV is strongly associated with coronary atherosclerosis in men.
Multi-detector CT angiography of the aortic valve—Part 2: disease specific findings
Ganeshan, Arul
2014-01-01
The aortic valve and adjacent structures should be routinely evaluated on all thoracic cross-sectional imaging studies. Echocardiography and magnetic resonance imaging (MRI) are the main imaging techniques used for assessment of the aortic valve and related pathology but multi-detector computed tomography (MDCT) can offer valuable complimentary information in some clinical scenarios. MDCT is the definite means of assessing aortic valvular calcification, acute aortic syndrome and for non-invasive assessment of the coronary arteries. MDCT also has an emerging role in the planning and follow-up of trans-catheter aortic valve replacement. This article reviews the spectrum of aortic valve disease highlighting the key MDCT imaging features. PMID:25202663
Cho, S H; Sung, Y M; Kim, M S
2012-01-01
Objective The objective of this study was to review the prevalence and radiological features of rib fractures missed on initial chest CT evaluation, and to examine the diagnostic value of additional coronal images in a large series of trauma patients. Methods 130 patients who presented to an emergency room for blunt chest trauma underwent multidetector row CT of the thorax within the first hour during their stay, and had follow-up CT or bone scans as diagnostic gold standards. Images were evaluated on two separate occasions: once with axial images and once with both axial and coronal images. The detection rates of missed rib fractures were compared between readings using a non-parametric method of clustered data. In the cases of missed rib fractures, the shapes, locations and associated fractures were evaluated. Results 58 rib fractures were missed with axial images only and 52 were missed with both axial and coronal images (p=0.088). The most common shape of missed rib fractures was buckled (56.9%), and the anterior arc (55.2%) was most commonly involved. 21 (36.2%) missed rib fractures had combined fractures on the same ribs, and 38 (65.5%) were accompanied by fracture on neighbouring ribs. Conclusion Missed rib fractures are not uncommon, and radiologists should be familiar with buckle fractures, which are frequently missed. Additional coronal imagescan be helpful in the diagnosis of rib fractures that are not seen on axial images. PMID:22514102
Watson, Tom Anthony; Arthurs, Owen John; Muthialu, Nagarajan; Calder, Alistair Duncan
2014-02-01
Cerebro-costo-mandibular syndrome (CCMS) describes a triad of mandibular hypoplasia, brain dysfunction and posterior rib defects ("rib gaps"). We present the CT imaging for a 2-year-old girl with CCMS that highlights the rib gap defects and shows absent transverse processes with abnormal fusion of the ribs directly to the vertebral bodies. We argue that this is likely to relate to abnormal lateral sclerotome development in embryology, with the failure of normal costo-vertebral junctions compounding impaired thoracic function. The case also highlights the use of CT for specific indications in skeletal dysplasia.
Keles, Papatya; Yuce, Ihsan; Keles, Sait; Kantarci, Mecit
2016-06-01
The aim of this study was to define the different courses and percentages of hepatic artery that were detected during preoperative evaluation of living liver donors by multidetector computed tomographic angiography (MDCTA). We evaluated 150 donors before hepatic transplantation. All of the donors were evaluated by multislice CT scan with 256 detectors. For each patient, arterial, portal and venous phase images were obtained. The hepatic arterial variations were evaluated by the same radiologist according to Michels' classification. Common hepatic arterial anatomy (type I) was observed in 95 donors (63.3%). Other arterial variations were determined in the remaining 55 donors (36.6%). The second common variation was type XI which did not match with the description of Michels' classification variation in 15 donors (10%). The remaining variations described in Michels' classification were seen at lower rates. Type VII or X variation was not seen. MDCTA is a useful method to identify the blood supply of the liver before the liver transplantations, and surgeons can make their plan on the basis of CT data.
NASA Astrophysics Data System (ADS)
Angel, Erin
Advances in Computed Tomography (CT) technology have led to an increase in the modality's diagnostic capabilities and therefore its utilization, which has in turn led to an increase in radiation exposure to the patient population. As a result, CT imaging currently constitutes approximately half of the collective exposure to ionizing radiation from medical procedures. In order to understand the radiation risk, it is necessary to estimate the radiation doses absorbed by patients undergoing CT imaging. The most widely accepted risk models are based on radiosensitive organ dose as opposed to whole body dose. In this research, radiosensitive organ dose was estimated using Monte Carlo based simulations incorporating detailed multidetector CT (MDCT) scanner models, specific scan protocols, and using patient models based on accurate patient anatomy and representing a range of patient sizes. Organ dose estimates were estimated for clinical MDCT exam protocols which pose a specific concern for radiosensitive organs or regions. These dose estimates include estimation of fetal dose for pregnant patients undergoing abdomen pelvis CT exams or undergoing exams to diagnose pulmonary embolism and venous thromboembolism. Breast and lung dose were estimated for patients undergoing coronary CTA imaging, conventional fixed tube current chest CT, and conventional tube current modulated (TCM) chest CT exams. The correlation of organ dose with patient size was quantified for pregnant patients undergoing abdomen/pelvis exams and for all breast and lung dose estimates presented. Novel dose reduction techniques were developed that incorporate organ location and are specifically designed to reduce close to radiosensitive organs during CT acquisition. A generalizable model was created for simulating conventional and novel attenuation-based TCM algorithms which can be used in simulations estimating organ dose for any patient model. The generalizable model is a significant contribution of this work as it lays the foundation for the future of simulating TCM using Monte Carlo methods. As a result of this research organ dose can be estimated for individual patients undergoing specific conventional MDCT exams. This research also brings understanding to conventional and novel close reduction techniques in CT and their effect on organ dose.
Jones, Jeryl C; Appt, Susan E; Werre, Stephen R; Tan, Joshua C; Kaplan, Jay R
2010-06-01
The purpose of this study was to validate low radiation dose, contrast-enhanced, multi-detector computed tomography (MDCT) as a non-invasive method for measuring ovarian volume in macaques. Computed tomography scans of four known-volume phantoms and nine mature female cynomolgus macaques were acquired using a previously described, low radiation dose scanning protocol, intravenous contrast enhancement, and a 32-slice MDCT scanner. Immediately following MDCT, ovaries were surgically removed and the ovarian weights were measured. The ovarian volumes were determined using water displacement. A veterinary radiologist who was unaware of actual volumes measured ovarian CT volumes three times, using a laptop computer, pen display tablet, hand-traced regions of interest, and free image analysis software. A statistician selected and performed all tests comparing the actual and CT data. Ovaries were successfully located in all MDCT scans. The iliac arteries and veins, uterus, fallopian tubes, cervix, ureters, urinary bladder, rectum, and colon were also consistently visualized. Large antral follicles were detected in six ovaries. Phantom mean CT volume was 0.702+/-SD 0.504 cc and the mean actual volume was 0.743+/-SD 0.526 cc. Ovary mean CT volume was 0.258+/-SD 0.159 cc and mean water displacement volume was 0.257+/-SD 0.145 cc. For phantoms, the mean coefficient of variation for CT volumes was 2.5%. For ovaries, the least squares mean coefficient of variation for CT volumes was 5.4%. The ovarian CT volume was significantly associated with actual ovarian volume (ICC coefficient 0.79, regression coefficient 0.5, P=0.0006) and the actual ovarian weight (ICC coefficient 0.62, regression coefficient 0.6, P=0.015). There was no association between the CT volume accuracy and mean ovarian CT density (degree of intravenous contrast enhancement), and there was no proportional or fixed bias in the CT volume measurements. Findings from this study indicate that MDCT is a valid non-invasive technique for measuring the ovarian volume in macaques.
Multidetector CT evaluation of the postoperative pancreas.
Yamauchi, Fernando I; Ortega, Cinthia D; Blasbalg, Roberto; Rocha, Manoel S; Jukemura, José; Cerri, Giovanni G
2012-01-01
Several pancreatic diseases may require surgical treatment, with most of these procedures classified as resection or drainage. Resection procedures, which are usually performed to remove pancreatic tumors, include pancreatoduodenectomy, central pancreatectomy, distal pancreatectomy, and total pancreatectomy. Drainage procedures are usually performed to treat chronic pancreatitis after the failure of medical therapy and include the Puestow and Frey procedures. The type of surgery depends not only on the patient's symptoms and the location of the disease, but also on the expertise of the surgeon. Radiologists should become familiar with these surgical procedures to better understand postoperative changes in anatomic findings. Multidetector computed tomography is the modality of choice for identifying normal findings after surgery, postoperative complications, and tumor recurrence in patients who have undergone pancreatic surgery. RSNA, 2012
Finkenstaedt, Tim; Morsbach, Fabian; Calcagni, Maurizio; Vich, Magdalena; Pfirrmann, Christian W A; Alkadhi, Hatem; Runge, Val M; Andreisek, Gustav; Guggenberger, Roman
2014-08-01
The aim of this study was to compare image quality and extent of artifacts from scaphoid fracture fixation screws using different computed tomography (CT) modalities and radiation dose protocols. Imaging of 6 cadaveric wrists with artificial scaphoid fractures and different fixation screws was performed in 2 screw positions (45° and 90° orientation in relation to the x/y-axis) using multidetector CT (MDCT) and 2 flat-panel CT modalities, C-arm flat-panel CT (FPCT) and cone-beam CT (CBCT), the latter 2 with low and standard radiation dose protocols. Mean cartilage attenuation and metal artifact-induced absolute Hounsfield unit changes (= artifact extent) were measured. Two independent radiologists evaluated different image quality criteria using a 5-point Likert-scale. Interreader agreements (Cohen κ) were calculated. Mean absolute Hounsfield unit changes and quality ratings were compared using Friedman and Wilcoxon signed-rank tests. Artifact extent was significantly smaller for MDCT and standard-dose FPCT compared with CBCT low- and standard-dose acquisitions (all P < 0.05). No significant differences in artifact extent among different screw types and scanning positions were noted (P > 0.05). Both MDCT and FPCT standard-dose protocols showed equal ratings for screw bone interface, fracture line, and trabecular bone evaluation (P = 0.06, 0.2, and 0.2, respectively) and performed significantly better than FPCT low- and CBCT low- and standard-dose acquisitions (all P < 0.05). Good interreader agreement was found for image quality comparisons (Cohen κ = 0.76-0.78). Both MDCT and FPCT standard-dose acquisition showed comparatively less metal-induced artifacts and better overall image quality compared with FPCT low-dose and both CBCT acquisitions. Flat-panel CT may provide sufficient image quality to serve as a versatile CT alternative for postoperative imaging of internally fixated wrist fractures.
Leyhe, Johanna Rosemarie; Tsogkas, Ioannis; Hesse, Amélie Carolina; Behme, Daniel; Schregel, Katharina; Papageorgiou, Ismini; Liman, Jan; Knauth, Michael; Psychogios, Marios-Nikos
2017-12-01
Flat detector CT (FDCT) has been used as a peri-interventional diagnostic tool in numerous studies with mixed results regarding image quality and detection of intracranial lesions. We compared the diagnostic aspects of the latest generation FDCT with standard multidetector CT (MDCT). 102 patients were included in our retrospective study. All patients had undergone interventional procedures. FDCT was acquired peri-interventionally and compared with postinterventional MDCT regarding depiction of ventricular/subarachnoidal spaces, detection of intracranial hemorrhage, and delineation of ischemic lesions using an ordinal scale. Ischemic lesions were quantified with the Alberta Stroke Program Early CT Scale (ASPECTS) on both examinations. Two neuroradiologists with varying grades of experience and a medical student scored the anonymized images separately, blinded to the clinical history. The two methods were of equal diagnostic value regarding evaluation of the ventricular system and the subarachnoidal spaces. Subarachnoidal, intraventricular, and parenchymal hemorrhages were detected with a sensitivity of 95%, 97%, and 100% and specificity of 97%, 100%, and 99%, respectively, using FDCT. Gray-white differentiation was feasible in the majority of FDCT scans, and ischemic lesions were detected with a sensitivity of 71% on FDCT, compared with MDCT scans. The mean difference in ASPECTS values on FDCT and MDCT was 0.5 points (95% CI 0.12 to 0.88). The latest generation of FDCT is a reliable and accurate tool for the detection of intracranial hemorrhage. Gray-white differentiation is feasible in the supratentorial region. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Jeon, Sun Kyung; Choi, Young Hun; Cheon, Jung-Eun; Kim, Woo Sun; Cho, Yeon Jin; Ha, Ji Young; Lee, Seung Hyun; Hyun, Hyejin; Kim, In-One
2018-04-01
The 320-row multidetector computed tomography (CT) scanner has multiple scan modes, including volumetric modes. To compare the image quality and radiation dose of 320-row CT in three acquisition modes - helical, one-shot volume, and wide-volume scan - at pediatric brain imaging. Fifty-seven children underwent unenhanced brain CT using one of three scan modes (helical scan, n=21; one-shot volume scan, n=17; wide-volume scan, n=19). For qualitative analysis, two reviewers evaluated overall image quality and image noise using a 5-point grading system. For quantitative analysis, signal-to-noise ratio, image noise and posterior fossa artifact index were calculated. To measure the radiation dose, adjusted CT dose index per unit volume (CTDI adj ) and dose length product (DLP) were compared. Qualitatively, the wide-volume scan showed significantly less image noise than the helical scan (P=0.009), and less streak artifact than the one-shot volume scan (P=0.001). The helical mode showed significantly lower signal-to-noise ratio, with a higher image noise level compared with the one-shot volume and wide-volume modes (all P<0.05). The CTDI adj and DLP were significantly lower in the one-shot volume and wide-volume modes compared with those in the helical scan mode (all P<0.05). For pediatric unenhanced brain CT, both the wide-volume and one-shot volume scans reduced radiation dose compared to the helical scan mode, while the wide-volume scan mode showed fewer streak artifacts in the skull vertex and posterior fossa than the one-shot volume scan.
Koizumi, Hiroshi; Sur, Jaideep; Seki, Kenji; Nakajima, Koh; Sano, Tsukasa; Okano, Tomohiro
2010-08-01
To assess effects of dose reduction on image quality in evaluating maxilla and mandible for pre-surgical implant planning using cadavers. Six cadavers were used for the study using multi-detector computed tomography (CT) operated at 120 kV and the variable tube current of 80, 40, 20 and 10 mA. A slice thickness of 0.625 mm and pitch 1 were used. Multi-planar images perpendicular and parallel to dentitions were created. The images were evaluated by five oral radiologists in terms of visibility of the anatomical landmarks including alveolar crest, mandibular canal, floors of the maxillary sinus and nasal cavity, contours/cortical layer of jaw bones and the details of trabecular bone. Observers were asked to determine the quality of the images in comparison with 80 mA images based on the criteria: excellent, good, fair or non-diagnostic. The average scores of all observers were calculated for each specimen in all exposure conditions. The 40 mA images could visualize such landmarks and were evaluated to be same or almost equivalent in quality to the 80 mA images. Even the 20 mA images could be accepted just for diagnostic purpose for implant with substantial deterioration of the image quality. The 10 mA images may not be accepted because of the obscured contour caused by image noise. Significant dose reduction by lowering mA can be utilized for pre-surgical implant planning in multi-detector CT.
Toyota, Naoyuki; Nakamura, Yuko; Hieda, Masashi; Akiyama, Naoko; Terada, Hiroaki; Matsuura, Noriaki; Nishiki, Masayo; Kono, Hirotaka; Kohno, Hiroshi; Irei, Toshimitsu; Yoshikawa, Yukinobu; Kuraoka, Kazuya; Taniyama, Kiyomi; Awai, Kazuo
2013-09-01
The purpose of this study was to evaluate the diagnostic capability of gadoxetate disodium (Gd-EOB)-MRI for the detection of hepatocellular carcinoma (HCC) compared with multidetector CT (MDCT). Fifty patients with 57 surgically proven HCCs who underwent Gd-EOB-MRI and MDCT from March 2008 to June 2011 were evaluated. Two observers evaluated MR and CT on a lesion-by-lesion basis. We analyzed sensitivity by grading on a 5-point scale, the degree of arterial enhancement and the differences in histological grades in the diffusion-weighted images (DWI). The results showed that the sensitivity of Gd-EOB-MRI was higher than that of MDCT especially for HCCs that were 1 cm in diameter or smaller. The hepatobiliary phase was useful for the detecting of small HCC. We had few cases in which it was difficult to judge HCC in the arterial enhancement between MRI and MDCT. In the diffusion-weighted image, well differentiated HCC tended to show a low signal intensity, and poorly differentiated HCC tended to show a high signal intensity. In moderately differentiated HCC's, the mean diameter of the high signal intensity group was larger than that of the low signal intensity group (24.5 mm vs. 15.8 mm). In conclusion, Gd-EOB-MRI tended to show higher sensitivity compared to MDCT in the detection of HCC.
2012-01-01
Background Growing evidence suggests that epicardial adipose tissue (EAT) may contribute to the development of coronary artery disease (CAD). In this study, we explored gender disparities in EAT volume (EATV) and its impact on coronary atherosclerosis. Methods The study population consisted of 90 consecutive subjects (age: 63 ± 12 years; men: 47, women: 43) who underwent 256-slice multi-detector computed tomography (MDCT) coronary angiography. EATV was measured as the sum of cross-sectional epicardial fat area on CT images, from the lower surface of the left pulmonary artery origin to the apex. Subjects were segregated into the CAD group (coronary luminal narrowing > 50%) and non-CAD group. Results EATV/body surface area (BSA) was higher among men in the CAD group than in the non-CAD group (62 ± 13 vs. 33 ± 10 cm3/m2, p < 0.0001), but did not differ significantly among women in the 2 groups (49 ± 18 vs. 42 ± 9 cm3/m2, not significant). Multivariate logistic analysis showed that EATV/BSA was the single predictor for >50% coronary luminal narrowing in men (p < 0.0001). Predictors excluded were age, body mass index, hypertension, diabetes mellitus, and hyperlipidemia. Conclusions Increased EATV is strongly associated with coronary atherosclerosis in men. PMID:22963346
Dose reduction in paediatric MDCT: general principles.
Paterson, A; Frush, D P
2007-06-01
The number of multi-detector array computed tomography (MDCT) examinations performed per annum continues to increase in both the adult and paediatric populations. Estimates from 2003 suggested that CT contributed 17% of a radiology department's workload, yet was responsible for up to 75% of the collective population dose from medical radiation. The effective doses for some CT examinations today overlap with those argued to have an increased risk of cancer. This is especially pertinent for paediatric CT, as children are more radiosensitive than adults (and girls more radiosensitive than boys). In addition, children have a longer life ahead of them, in which radiation induced cancers may become manifest. Radiologists must be aware of these facts and practise the ALARA (as low as is reasonably achievable) principle, when it comes to deciding CT protocols and parameters.
Demehri, S; Muhit, A; Zbijewski, W; Stayman, J W; Yorkston, J; Packard, N; Senn, R; Yang, D; Foos, D; Thawait, G K; Fayad, L M; Chhabra, A; Carrino, J A; Siewerdsen, J H
2015-06-01
To assess visualization tasks using cone-beam CT (CBCT) compared to multi-detector CT (MDCT) for musculoskeletal extremity imaging. Ten cadaveric hands and ten knees were examined using a dedicated CBCT prototype and a clinical multi-detector CT using nominal protocols (80 kVp-108mAs for CBCT; 120 kVp- 300 mAs for MDCT). Soft tissue and bone visualization tasks were assessed by four radiologists using five-point satisfaction (for CBCT and MDCT individually) and five-point preference (side-by-side CBCT versus MDCT image quality comparison) rating tests. Ratings were analyzed using Kruskal-Wallis and Wilcoxon signed-rank tests, and observer agreement was assessed using the Kappa-statistic. Knee CBCT images were rated "excellent" or "good" (median scores 5 and 4) for "bone" and "soft tissue" visualization tasks. Hand CBCT images were rated "excellent" or "adequate" (median scores 5 and 3) for "bone" and "soft tissue" visualization tasks. Preference tests rated CBCT equivalent or superior to MDCT for bone visualization and favoured the MDCT for soft tissue visualization tasks. Intraobserver agreement for CBCT satisfaction tests was fair to almost perfect (κ ~ 0.26-0.92), and interobserver agreement was fair to moderate (κ ~ 0.27-0.54). CBCT provided excellent image quality for bone visualization and adequate image quality for soft tissue visualization tasks. • CBCT provided adequate image quality for diagnostic tasks in extremity imaging. • CBCT images were "excellent" for "bone" and "good/adequate" for "soft tissue" visualization tasks. • CBCT image quality was equivalent/superior to MDCT for bone visualization tasks.
Konecki, Dariusz; Grabowska-Derlatka, Laretta; Pacho, Ryszard; Rowiński, Olgierd
2017-01-01
Endoscopic methods (gastroscopy and colonoscopy) are considered fundamental for the diagnosis of gastrointestinal bleeding. In recent years, multidetector computed tomography (MDCT) has also gained importance in diagnosing gastrointestinal bleeding, particularly in hemodynamically unstable patients and in cases with suspected lower gastrointestinal tract bleeding. CT can detect both the source and the cause of active gastrointestinal bleeding, thereby expediting treatment initiation. The study group consisted of 16 patients with clinical symptoms of gastrointestinal bleeding in whom features of active bleeding were observed on CT. In all patients, bleeding was verified by means of other methods such as endoscopic examinations, endovascular procedures, or surgery. The bleeding source was identified on CT in all 16 patients. In 14 cases (87.5%), bleeding was confirmed by other methods. CT is an efficient, fast, and readily available tool for detecting the location of acute gastrointestinal bleeding.
Dual-energy CT revisited with multidetector CT: review of principles and clinical applications.
Karçaaltıncaba, Muşturay; Aktaş, Aykut
2011-09-01
Although dual-energy CT (DECT) was first conceived in the 1970s, it was not widely used for CT indications. Recently, the simultaneous acquisition of volumetric dual-energy data has been introduced using multidetector CT (MDCT) with two X-ray tubes and rapid kVp switching (gemstone spectral imaging). Two major advantages of DECT are material decomposition by acquiring two image series with different kVp and the elimination of misregistration artifacts. Hounsfield unit measurements by DECT are not absolute and can change depending on the kVp used for an acquisition. Typically, a combination of 80/140 kVp is used for DECT, but for some applications, 100/140 kVp is preferred. In this study, we summarized the clinical applications of DECT and included images that were acquired using the dual-source CT and rapid kVp switching. In general, unenhanced images can be avoided by using DECT for body and neurological applications; iodine can be removed from the image, and a virtual, non-contrast (water) image can be obtained. Neuroradiological applications allow for the removal of bone and calcium from the carotid and brain CT angiography. Thorax applications include perfusion imaging in patients with pulmonary thromboemboli and other chest diseases, xenon ventilation-perfusion imaging and solitary nodule characterization. Cardiac applications include dual-energy cardiac perfusion, viability and cardiac iron detection. The removal of calcific plaques from arteries, bone removal and aortic stent graft evaluation may be achieved in the vascular system. Abdominal applications include the detection and characterization of liver and pancreas masses, the diagnosis of steatosis and iron overload, DECT colonoscopy and CT cholangiography. Urinary system applications are urinary calculi characterization (uric acid vs. non-uric acid), renal cyst characterization and mass characterization. Musculoskeletal applications permit the differentiation of gout from pseudogout and a reduction of metal artifacts. Recent introduction of iterative reconstruction techniques can increase the use of DECT techniques; the use of dual energy in patients with a high BMI is limited due to noise and the radiation dose. DECT may be a good alternative to PET-CT. Iodine map images can quantify iodine uptake, and this approach may be more effective than obtaining non-contrast and post-contrast images for the diagnosis of a solid mass. Thus, computer-aided detection may be used more effectively in CT applications. DECT is a promising technique with potential clinical applications.
Williams, Michelle C; Golay, Saroj K; Hunter, Amanda; Weir-McCall, Jonathan R; Mlynska, Lucja; Dweck, Marc R; Uren, Neal G; Reid, John H; Lewis, Steff C; Berry, Colin; van Beek, Edwin J R; Roditi, Giles; Newby, David E; Mirsadraee, Saeed
2015-01-01
Introduction Observer variability can influence the assessment of CT coronary angiography (CTCA) and the subsequent diagnosis of angina pectoris due to coronary heart disease. Methods We assessed 210 CTCAs from the Scottish COmputed Tomography of the HEART (SCOT-HEART) trial for intraobserver and interobserver variability. Calcium score, coronary angiography and image quality were evaluated. Coronary artery disease was defined as none (<10%), mild (10–49%), moderate (50–70%) and severe (>70%) luminal stenosis and classified as no (<10%), non-obstructive (10–70%) or obstructive (>70%) coronary artery disease. Post-CTCA diagnosis of angina pectoris due to coronary heart disease was classified as yes, probable, unlikely or no. Results Patients had a mean body mass index of 29 (28, 30) kg/m2, heart rate of 58 (57, 60)/min and 62% were men. Intraobserver and interobserver agreements for the presence or absence of coronary artery disease were excellent (95% agreement, κ 0.884 (0.817 to 0.951) and good (91%, 0.791 (0.703 to 0.879)). Intraobserver and interobserver agreement for the presence or absence of angina pectoris due to coronary heart disease were excellent (93%, 0.842 (0.918 to 0.755) and good (86%, 0.701 (0.799 to 0.603)), respectively. Observer variability of calcium score was excellent for calcium scores below 1000. More segments were categorised as uninterpretable with 64-multidetector compared to 320-multidetector CTCA (10.1% vs 2.6%, p<0.001) but there was no difference in observer variability. Conclusions Multicentre multidetector CTCA has excellent agreement in patients under investigation for suspected angina due to coronary heart disease. Trial registration number NCT01149590. PMID:26019881
Tack, Denis; Jahnen, Andreas; Kohler, Sarah; Harpes, Nico; De Maertelaer, Viviane; Back, Carlo; Gevenois, Pierre Alain
2014-01-01
To report short- and long-term effects of an audit process intended to optimise the radiation dose from multidetector row computed tomography (MDCT). A survey of radiation dose from all eight MDCT departments in the state of Luxembourg performed in 2007 served as baseline, and involved the most frequently imaged regions (head, sinus, cervical spine, thorax, abdomen, and lumbar spine). CT dose index volume (CTDIvol), dose-length product per acquisition (DLP/acq), and DLP per examination (DLP/exa) were recorded, and their mean, median, 25th and 75th percentiles compared. In 2008, an audit conducted in each department helped to optimise doses. In 2009 and 2010, two further surveys evaluated the audit's impact on the dose delivered. Between 2007 and 2009, DLP/exa significantly decreased by 32-69 % for all regions (P < 0.001) except the lumbar spine (5 %, P = 0.455). Between 2009 and 2010, DLP/exa significantly decreased by 13-18 % for sinus, cervical and lumbar spine (P ranging from 0.016 to less than 0.001). Between 2007 and 2010, DLP/exa significantly decreased for all regions (18-75 %, P < 0.001). Collective dose decreased by 30 % and the 75th percentile (diagnostic reference level, DRL) by 20-78 %. The audit process resulted in long-lasting dose reduction, with DRLs reduced by 20-78 %, mean DLP/examination by 18-75 %, and collective dose by 30 %. • External support through clinical audit may optimise default parameters of routine CT. • Reduction of 75th percentiles used as reference diagnostic levels is 18-75 %. • The effect of this audit is sustainable over time. • Dose savings through optimisation can be added to those achievable through CT.
Koyoshi, Rie; Shiga, Yuhei; Idemoto, Yoshiaki; Ueda, Yoko; Tashiro, Kohei; Kuwano, Takashi; Kitajima, Ken; Fujimi, Kanta; Kawamura, Akira; Ogawa, Masahiro; Miura, Shin-Ichiro
2018-01-01
We evaluated the safety of a bolus injection of landiolol hydrochloride, an ultrashort-acting β1-selective antagonist, as a premedication prior to multidetector-row computed tomography coronary angiography (CTA). The subjects consisted of 176 patients (M/F = 64:112, 67 ± 11 years) who had heart rate (HR) at rest ≥ 70 beats/min (bpm) and underwent CTA. Systolic/diastolic blood pressure (SBP/DBP) and HR were measured before and after the administration of landiolol. SBP/DBP and HR upon entry to the CT room were 136 ± 17/80 ± 11 mm Hg and 83 ± 10 bpm, respectively. HR was significantly reduced at the time of CTA scan (62 ± 7 bpm). Next, we divided the patients into three groups according to HR upon entry to the CT room: 70 - 79 bpm (n = 76), 80 - 89 bpm (n = 60) and ≥ 90 bpm (n = 40). HR at the time of CTA scan was significantly lower than that upon entry to the CT room in all three groups: 70 - 79 bpm (74 ± 3 bpm upon entry to the CT room to 61 ± 6 bpm at the time of CAT scan), 80 - 89 bpm (84 ± 3 to 63 ± 7 bpm) and ≥ 90 bpm (98 ± 6 to 65 ± 7 bpm). Although SBP/DBP was significantly decreased after the CTA scan (123 ± 18/72 ± 12 mm Hg), landiolol had no severe adverse events throughout CTA. In conclusion, a bolus injection of landiolol reduced HR by about 20 bpm without any severe adverse effects. Thus, a bolus injection of landiolol hydrochloride may be a suitable pretreatment for controlling HR in CTA.
Stratis, Andreas; Zhang, Guozhi; Lopez-Rendon, Xochitl; Politis, Constantinus; Hermans, Robert; Jacobs, Reinhilde; Bogaerts, Ria; Shaheen, Eman; Bosmans, Hilde
2017-09-01
To calculate organ doses and estimate the effective dose for justification purposes in patients undergoing orthognathic treatment planning purposes and temporal bone imaging in dental cone beam CT (CBCT) and Multidetector CT (MDCT) scanners. The radiation dose to the ICRP reference male voxel phantom was calculated for dedicated orthognathic treatment planning acquisitions via Monte Carlo simulations in two dental CBCT scanners, Promax 3D Max (Planmeca, FI) and NewTom VGi evo (QR s.r.l, IT) and in Somatom Definition Flash (Siemens, DE) MDCT scanner. For temporal bone imaging, radiation doses were calculated via MC simulations for a CBCT protocol in NewTom 5G (QR s.r.l, IT) and with the use of a software tool (CT-expo) for Somatom Force (Siemens, DE). All procedures had been optimized at the acceptance tests of the devices. For orthognathic protocols, dental CBCT scanners deliver lower doses compared to MDCT scanners. The estimated effective dose (ED) was 0.32mSv for a normal resolution operation mode in Promax 3D Max, 0.27mSv in VGi-evo and 1.18mSv in the Somatom Definition Flash. For temporal bone protocols, the Somatom Force resulted in an estimated ED of 0.28mSv while for NewTom 5G the ED was 0.31 and 0.22mSv for monolateral and bilateral imaging respectively. Two clinical exams which are carried out with both a CBCT or a MDCT scanner were compared in terms of radiation dose. Dental CBCT scanners deliver lower doses for orthognathic patients whereas for temporal bone procedures the doses were similar. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Barrett, H E; Cunnane, E M; O Brien, J M; Moloney, M A; Kavanagh, E G; Walsh, M T
2017-10-01
The purpose of this study is to determine the optimal target CT spatial resolution for accurately imaging abdominal aortic aneurysm (AAA) wall characteristics, distinguishing between tissue and calcification components, for an accurate assessment of rupture risk. Ruptured and non-ruptured AAA-wall samples were acquired from eight patients undergoing open surgical aneurysm repair upon institutional review board approval and informed consent was obtained from all patients. Physical measurements of AAA-wall cross-section were made using scanning electron microscopy. Samples were scanned using high resolution micro-CT scanning. A resolution range of 15.5-155μm was used to quantify the influence of decreasing resolution on wall area measurements, in terms of tissue and calcification. A statistical comparison between the reference resolution (15.5μm) and multi-detector CT resolution (744μm) was also made. Electron microscopy examination of ruptured AAAs revealed extremely thin outer tissue structure <200μm in radial distribution which is supporting the aneurysm wall along with large areas of adjacent medial calcifications far greater in area than the tissue layer. The spatial resolution of 155μm is a significant predictor of the reference AAA-wall tissue and calcification area measurements (r=0.850; p<0.001; r=0.999; p<0.001 respectively). The tissue and calcification area at 155μm is correct within 8.8%±1.86 and 26.13%±9.40 respectively with sensitivity of 87.17% when compared to the reference. The inclusion of AAA-wall measurements, through the use of high resolution-CT will elucidate the variations in AAA-wall tissue and calcification distributions across the wall which may help to leverage an improved assessment of AAA rupture risk. Copyright © 2017 Elsevier B.V. All rights reserved.
Low-contrast detectability in volume rendering: a phantom study on multidetector-row spiral CT data.
Shin, Hoen-Oh; Falck, Christian V; Galanski, Michael
2004-02-01
To cope with the increasing amount of CT data, there is growing interest in direct volume-rendering techniques (VRT) as a diagnostic tool. The aim of this phantom study was to analyze the low-contrast detectability (LCD) of VRT compared with multi-planar reformations (MPR). Soft tissue lesions were simulated by spheres of different diameters (3-8 mm). The average lesion density was 15 HU compared with a background density of 35 HU. Two different CT protocols with 40 and 150 mAs were performed on a multi-detector row CT. The scanning parameters were as following: 140 kV; 2x0.5-mm slice collimation; pitch 2 (table movement per rotation/single slice collimation), and reconstruction with 0.5-mm slice thickness at 0.5-mm interval. A B30 kernel was used for reconstruction. The VRT was performed by mapping Hounsfield values to gray levels equal to a CT window (center: 60 HU; window: 370 HU ). A linear ramp was applied for the opacity transfer function varying the maximum opacity between 0.1 and 1.0. A statistical method based on the Rose model was used to calculate the detection threshold depending on lesion size and image noise. Additionally, clinical data of 2 patients with three liver lesions of different sizes and density were evaluated. In VRT, LCD was most dependent on object size. Regarding lesions larger than 5 mm, VRT is significantly superior to MPR (p<0.05) for all opacity settings. In lesions sized 3-5 mm a maximum opacity level approximately 40-50% showed a near equivalent detectability in VRT and MPR. For higher opacity levels VRT was superior to MPR. Only for 3-mm lesions MPR performed slightly better in low-contrast detectability (p<0.05). Compared with MPR, VRT shows similar performance in LCD. Due to noise suppression effects, it is suited for visualization of data with high noise content.
Kim, Sangroh; Yoshizumi, Terry T; Toncheva, Greta; Frush, Donald P; Yin, Fang-Fang
2010-03-01
The purpose of this study was to establish a dose estimation tool with Monte Carlo (MC) simulations. A 5-y-old paediatric anthropomorphic phantom was computed tomography (CT) scanned to create a voxelised phantom and used as an input for the abdominal cone-beam CT in a BEAMnrc/EGSnrc MC system. An X-ray tube model of the Varian On-Board Imager((R)) was built in the MC system. To validate the model, the absorbed doses at each organ location for standard-dose and low-dose modes were measured in the physical phantom with MOSFET detectors; effective doses were also calculated. In the results, the MC simulations were comparable to the MOSFET measurements. This voxelised phantom approach could produce a more accurate dose estimation than the stylised phantom method. This model can be easily applied to multi-detector CT dosimetry.
MDCT imaging of the stomach: advances and applications
Prakash, Anjali; Pradhan, Gaurav; Vidholia, Aditi; Nagpal, Nishant; Saboo, Sachin S; Kuehn, David M; Khandelwal, Ashish
2017-01-01
The stomach may be involved by a myriad of pathologies ranging from benign aetiologies like inflammation to malignant aetiologies like carcinoma or lymphoma. Multidetector CT (MDCT) of the stomach is the first-line imaging for patients with suspected gastric pathologies. Conventionally, CT imaging had the advantage of simultaneous detection of the mural and extramural disease extent, but advances in MDCT have allowed mucosal assessment by virtual endoscopy (VE). Also, better three-dimensional (3D) post-processing techniques have enabled more robust and accurate pre-operative planning in patients undergoing gastrectomy and even predict the response to surgery for patients undergoing laparoscopic sleeve gastrectomy for weight loss. The ability of CT to obtain stomach volume (for bariatric surgery patients) and 3D VE images depends on various patient and protocol factors that are important for a radiologist to understand. We review the appropriate CT imaging protocol in the patients with suspected gastric pathologies and highlight the imaging pearls of various gastric pathologies on CT and VE. PMID:27785936
MDCT imaging of the stomach: advances and applications.
Nagpal, Prashant; Prakash, Anjali; Pradhan, Gaurav; Vidholia, Aditi; Nagpal, Nishant; Saboo, Sachin S; Kuehn, David M; Khandelwal, Ashish
2017-01-01
The stomach may be involved by a myriad of pathologies ranging from benign aetiologies like inflammation to malignant aetiologies like carcinoma or lymphoma. Multidetector CT (MDCT) of the stomach is the first-line imaging for patients with suspected gastric pathologies. Conventionally, CT imaging had the advantage of simultaneous detection of the mural and extramural disease extent, but advances in MDCT have allowed mucosal assessment by virtual endoscopy (VE). Also, better three-dimensional (3D) post-processing techniques have enabled more robust and accurate pre-operative planning in patients undergoing gastrectomy and even predict the response to surgery for patients undergoing laparoscopic sleeve gastrectomy for weight loss. The ability of CT to obtain stomach volume (for bariatric surgery patients) and 3D VE images depends on various patient and protocol factors that are important for a radiologist to understand. We review the appropriate CT imaging protocol in the patients with suspected gastric pathologies and highlight the imaging pearls of various gastric pathologies on CT and VE.
Konecki, Dariusz; Pacho, Ryszard; Rowiński, Olgierd
2017-01-01
Summary Background Endoscopic methods (gastroscopy and colonoscopy) are considered fundamental for the diagnosis of gastrointestinal bleeding. In recent years, multidetector computed tomography (MDCT) has also gained importance in diagnosing gastrointestinal bleeding, particularly in hemodynamically unstable patients and in cases with suspected lower gastrointestinal tract bleeding. CT can detect both the source and the cause of active gastrointestinal bleeding, thereby expediting treatment initiation. Material/Methods The study group consisted of 16 patients with clinical symptoms of gastrointestinal bleeding in whom features of active bleeding were observed on CT. In all patients, bleeding was verified by means of other methods such as endoscopic examinations, endovascular procedures, or surgery. Results The bleeding source was identified on CT in all 16 patients. In 14 cases (87.5%), bleeding was confirmed by other methods. Conclusions CT is an efficient, fast, and readily available tool for detecting the location of acute gastrointestinal bleeding. PMID:29662594
CT angiography of the renal arteries and veins: normal anatomy and variants.
Hazırolan, Tuncay; Öz, Meryem; Türkbey, Barış; Karaosmanoğlu, Ali Devrim; Oğuz, Berna Sayan; Canyiğit, Murat
2011-03-01
Conventional angiography has long been regarded as gold standard imaging modality for evaluation of the renal vasculature. Introduction of multidetector computed tomography (MDCT) angiography had a groundbreaking impact on evaluation of the renal vessels and is gradually replacing conventional angiography as standard imaging. Herein, we review and illustrate the normal and variant anatomy of renal vessels with special emphasis on imaging protocols and reconstruction techniques in MDCT.
Tsili, Athina C; Argyropoulou, Maria I
2015-01-01
Renal cell carcinoma (RCC) accounts for approximately 90%-95% of kidney tumors. With the widespread use of cross-sectional imaging modalities, more than half of RCCs are detected incidentally, often diagnosed at an early stage. This may allow the planning of more conservative treatment strategies. Computed tomography (CT) is considered the examination of choice for the detection and staging of RCC. Multidetector CT (MDCT) with the improvement of spatial resolution and the ability to obtain multiphase imaging, multiplanar and three-dimensional reconstructions in any desired plane brought about further improvement in the evaluation of RCC. Differentiation of RCC from benign renal tumors based on MDCT features is improved. Tumor enhancement characteristics on MDCT have been found closely to correlate with the histologic subtype of RCC, the nuclear grade and the cytogenetic characteristics of clear cell RCC. Important information, including tumor size, localization, and organ involvement, presence and extent of venous thrombus, possible invasion of adjacent organs or lymph nodes, and presence of distant metastases are provided by MDCT examination. The preoperative evaluation of patients with RCC was improved by depicting the presence or absence of renal pseudocapsule and by assessing the possible neoplastic infiltration of the perirenal fat tissue and/or renal sinus fat compartment. PMID:26120380
Posterior semicircular canal dehiscence: value of VEMP and multidetector CT.
Vanspauwen, R; Salembier, L; Van den Hauwe, L; Parizel, P; Wuyts, F L; Van de Heyning, P H
2006-01-01
To illustrate that posterior semicircular canal dehiscence can present similarly to superior semicircular canal dehiscence. The symptomatology initially presented as probable Menière's disease evolving into a mixed conductive hearing loss with a Carhart notch-type perceptive component suggestive of otosclerosis-type stapes fixation. A small hole stapedotomy resulted in a dead ear and a horizontal semicircular canal hypofunction. Recurrent incapacitating vertigo attacks developed. Vestibular evoked myogenic potential (VEMP) testing demonstrated intact vestibulocollic reflexes. Additional evaluation with high resolution multidetector computed tomography (MDCT) of the temporal bone showed a dehiscence of the left posterior semicircular canal. Besides superior semicircular canal dehiscence, posterior semicircular canal dehiscence has to be included in the differential diagnosis of atypical Menière's disease and/or low tone conductive hearing loss. The value of performing MDCT before otosclerosis-type surgery is stressed. VEMP might contribute to establishing the differential diagnosis.
Eren, Suat
2010-01-01
Objective: To evaluate the efficacy of multi-detector row CT (MDCT) on pelvic congestion syndrome (PCS), which is often overlooked or poorly visualized with routine imaging examination. Materials and Methods: We evaluated the MDCT features of 40 patients with PCS (mean age, 45 years; range, 29–60 years) using axial, coronal, sagittal, 3D volume-rendered, and Maximum Intensity Projection MIP images. Results: MDCT revealed pelvic varices and ovarian vein dilatations in all patients. Bilateral ovarian vein dilatation was present in 25 patients, and 15 patients had unilateral dilatation. While 12 cases of secondary pelvic varices occurred simultaneously with a retroaortic left renal vein, 10 cases were due solely to a mass obstruction or stenosis of venous structures. Conclusion: MDCT is an effective tool in the evaluation of PCS, and it has more advantages than other imaging modalities. PMID:25610142
Osteoporosis Imaging: State of the Art and Advanced Imaging
2012-01-01
Osteoporosis is becoming an increasingly important public health issue, and effective treatments to prevent fragility fractures are available. Osteoporosis imaging is of critical importance in identifying individuals at risk for fractures who would require pharmacotherapy to reduce fracture risk and also in monitoring response to treatment. Dual x-ray absorptiometry is currently the state-of-the-art technique to measure bone mineral density and to diagnose osteoporosis according to the World Health Organization guidelines. Motivated by a 2000 National Institutes of Health consensus conference, substantial research efforts have focused on assessing bone quality by using advanced imaging techniques. Among these techniques aimed at better characterizing fracture risk and treatment effects, high-resolution peripheral quantitative computed tomography (CT) currently plays a central role, and a large number of recent studies have used this technique to study trabecular and cortical bone architecture. Other techniques to analyze bone quality include multidetector CT, magnetic resonance imaging, and quantitative ultrasonography. In addition to quantitative imaging techniques measuring bone density and quality, imaging needs to be used to diagnose prevalent osteoporotic fractures, such as spine fractures on chest radiographs and sagittal multidetector CT reconstructions. Radiologists need to be sensitized to the fact that the presence of fragility fractures will alter patient care, and these fractures need to be described in the report. This review article covers state-of-the-art imaging techniques to measure bone mineral density, describes novel techniques to study bone quality, and focuses on how standard imaging techniques should be used to diagnose prevalent osteoporotic fractures. © RSNA, 2012 PMID:22438439
Rana, A K; Turner, H E; Deans, K A
2013-01-01
Patients with suspected subarachnoid haemorrhage, a normal noncontrast computed tomography (CT) and cerebrospinal fluid (CSF) evidence of haemoglobin breakdown products often undergo CT angiography (CTA). If this is normal, then invasive catheter angiography may be offered. In current clinical practice, haemoglobin breakdown products are detected by spectrophotometry rather than visible xanthochromia, and CTA is performed on multidetector scanners. The aim of this study was to determine if such patients should still have a catheter angiography, given the associated risks. Patients positive for CSF spectrophotometry (n=26) were retrospectively identified from the clinical biochemistry information system and imaging data from the electronic radiology records were reviewed. Discharge letters were consulted to relate the biochemistry and radiology results to the final diagnosis. 15 patients with CT angiography were found. Nine patients had normal CT angiography. No causative aneurysms had been missed. One patient had small, coincidental aneurysms missed on initial reading of the CTA. The likelihood of a clinically significant aneurysm in a patient who is CT negative, lumbar puncture positive and CTA negative is low. Double reporting of negative CT angiograms may be advisable.
[Chronic pancreatitis: which is the role of 320-row CT for the staging?].
Stabile Ianora, Amato Antonio; Rubini, Giuseppe; Lorusso, Filomenamila; Ambriola, Angela; Rella, Leonarda; Di Crescenzo, Vincenzo; Moschetta, Marco
2013-01-01
The purpose of this study was to evaluate the diagnostic potential of multi-planar and volumetric reconstructions obtained from isotropic data by using 16-slice computed tomography (CT) in the diagnosis and staging of chronic pancreatitis. In a group of 42 patients CT images were evaluated searching for alterations in morphology and structure of the pancreas, alterations of the Wirsung duct, dilatation of the bile ducts, fluid collections, and vascular involvement of the digestive tract. The disease was then staged in mild, moderate and severe and correlated with the clinical staging. CT allowed the recognition of chronic pancreatitis in all cases. The staging was correct in 25/42 patients, with an accuracy rate of 59.5%. In the staging of moderate and severe forms, CT correlation with clinical and laboratory data was valid, but in mild forms it appeared less significant. Multi-detector CT is accurate in the recognition of moderate, advanced forms of chronic pancreatitis and in the identification of its complications, while it is poorly correlated with the clinical staging in mild forms of the disease.
Paleoradiology: advanced CT in the evaluation of nine Egyptian mummies.
Hoffman, Heidi; Torres, William E; Ernst, Randy D
2002-01-01
Axial thin-collimation state-of-the-art spiral computed tomography (CT) was combined with sagittal and coronal reformatting, three-dimensional (3D) reconstruction, and virtual "fly-through" techniques to nondestructively study nine Egyptian mummies. These techniques provided important paleopathologic and historical information about mummification techniques, depicted anatomy in the most informative imaging plane, illustrated the soft-tissue preservation and physical appearance of mummies in superb detail, and generated an intriguing virtual tour through hollow mummified remains without harming the specimens themselves. Images generated with these methods can help archaeologists and Egyptologists understand these fascinating members of mankind and can serve as adjunct visual aids for laypersons who are interested in mummies. CT has emerged as the imaging modality of choice for the examination of Egyptian mummies due to its noninvasive cross-sectional nature and inherently superior contrast and spatial resolution. As multi-detector row CT and postprocessing tools evolve, the capabilities and applications of CT will continue to proliferate, attesting to the expanded versatility and utility of CT as a noninvasive research tool in the multidisciplinary study of Egyptian mummies. Copyright RSNA, 2002
Gooley, Robert P; Cameron, James D; Soon, Jennifer; Loi, Duncan; Chitale, Gauri; Syeda, Rifath; Meredith, Ian T
2015-09-01
Multidetector computed tomographic (MDCT) assessment of the aortoventricular interface has gained increased importance with the advent of minimally invasive treatment modalities for aortic and mitral valve disease. This has included a standardised technique of identifying a plane through the nadir of each coronary cusp, the basal plane, and taking further measurements in relation to this plane. Despite this there is no published data defining normal ranges for these aortoventricular metrics in a healthy cohort. This study seeks to quantify normative ranges for MDCT derived aortoventricular dimensions and evaluate baseline demographic and anthropomorphic associates of these measurements in a normal cohort. 250 consecutive patients undergoing MDCT coronary angiography were included. Aortoventricular dimensions at multiple levels of the aortoventricular interface were assessed and normative ranges quantified. Multivariate linear regression was performed to identify baseline predictors of each metric. The mean age was 59±12 years. The basal plane was eccentric (EI=0.22±0.06) while the left ventricular outflow tract was more eccentric (EI=0.32±0.06), with no correlation to gender, age or hypertension. Male gender, height and body mass index were consistent independent predictors of larger aortoventricular dimensions at all anatomical levels, while age was predictive of supra-annular measurements. Male gender, height and BMI are independent predictors of all aortoventricular dimensions while age predicts only supra-annular dimensions. Use of defined metrics such as the basal plane and formation of normative ranges for these metrics allows reference for clinical reporting and for future research studies by using a standardised measurement technique. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Physical analysis of breast cancer using dual-source computed tomography
NASA Astrophysics Data System (ADS)
Kim, H. J.; Lee, H. K.; Cho, J. H.
2014-12-01
This study was aimed to analyze various physical characteristics of breast cancer using dual-source computed tomography (CT). A phantom study and a clinical trial were performed in order and a 64-multidetector CT device was used for the examinations. In the phantom study, single-source (SS) CT was set up with a conventional scanning condition that is usually applied for breast CT examination and implementation was done at tube voltage of 120 kVp. Dual-source CT acquired images by irradiating X-ray sources with fast switching between two kilovoltage settings (80 and 140 kVp). After scanning, Hounsfield Unit (HU) values and radiation doses in a region of interest were measured and analyzed. In the clinical trial, the HU values were measured and analyzed after single-source computed tomography (SSCT) and dual-source CT in patients diagnosed with breast cancer. Also, the tumor size measured by dual-source CT was compared with the actual tumor size. The phantom study determined that the tumor region was especially measured by dual-source CT, while nylon fiber and specks region were especially measured by SSCT. The radiation dose was high with dual-source CT. The clinical trial showed a higher HU value of cancerous regions when scanned by dual-source CT compared with SSCT.
Electrocardiographically gated 16-section CT of the thorax: cardiac motion suppression.
Hofmann, Lars K; Zou, Kelly H; Costello, Philip; Schoepf, U Joseph
2004-12-01
Thirty patients underwent 16-section multi-detector row computed tomographic (CT) angiography of the thorax with retrospective electrocardiographic gating. Institutional review board approval was obtained for retrospective analysis of CT scan data and records; patient informed consent was not required. Images reconstructed at six different time points (0%, 20%, 40%, 50%, 60%, 80%) within the R-R interval on the electrocardiogram were analyzed by two radiologists for diagnostic quality, to identify suitable reconstruction intervals for optimal suppression of cardiac motion. Five regions of interest (left coronary artery, aortic root, ascending and descending aorta, pulmonary arteries) were evaluated. Best image quality was achieved by referencing image reconstruction to middiastole (50%-60%) for the left coronary artery, aortic root, and ascending aorta. The pulmonary arteries are best displayed during mid- to late diastole (80%). (c) RSNA, 2004
Iacobellis, Francesca; Ierardi, Anna M; Mazzei, Maria A; Magenta Biasina, Alberto; Carrafiello, Gianpaolo; Nicola, Refky; Scaglione, Mariano
2016-01-01
Acute vascular injuries are the second most common cause of fatalities in patients with multiple traumatic injuries; thus, prompt identification and management is essential for patient survival. Over the past few years, multidetector CT (MDCT) using dual-phase scanning protocol has become the imaging modality of choice in high-energy deceleration traumas. The objective of this article was to review the role of dual-phase MDCT in the identification and management of acute vascular injuries, particularly in the chest and abdomen following multiple traumatic injuries. In addition, this article will provide examples of MDCT features of acute vascular injuries with correlative surgical and interventional findings.
Recent advances in imaging cancer of the kidney and urinary tract.
Hilton, Susan; Jones, Lisa P
2014-10-01
Modern radiologic imaging is an aid to treatment planning for localized renal cancer, enabling characterization of mass lesions. For patients who present with advanced renal cancer, new imaging techniques enable a functional assessment of treatment response not possible using anatomic measurements alone. Multidetector CT urography permits simultaneous assessment of the kidneys and urinary tract for patients with unexplained hematuria. Both CT and MRI play a significant role in staging and follow up of patients treated for urothelial cancer. Newer imaging methods such as diffusion-weighted MRI have shown promising results for improving accuracy of staging and follow up of urothelial cancer. Copyright © 2014 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Angel, Erin; Yaghmai, Nazanin; Matilda Jude, Cecilia; DeMarco, John J.; Cagnon, Christopher H.; Goldin, Jonathan G.; Primak, Andrew N.; Stevens, Donna M.; Cody, Dianna D.; McCollough, Cynthia H.; McNitt-Gray, Michael F.
2009-02-01
Tube current modulation was designed to reduce radiation dose in CT imaging while maintaining overall image quality. This study aims to develop a method for evaluating the effects of tube current modulation (TCM) on organ dose in CT exams of actual patient anatomy. This method was validated by simulating a TCM and a fixed tube current chest CT exam on 30 voxelized patient models and estimating the radiation dose to each patient's glandular breast tissue. This new method for estimating organ dose was compared with other conventional estimates of dose reduction. Thirty detailed voxelized models of patient anatomy were created based on image data from female patients who had previously undergone clinically indicated CT scans including the chest area. As an indicator of patient size, the perimeter of the patient was measured on the image containing at least one nipple using a semi-automated technique. The breasts were contoured on each image set by a radiologist and glandular tissue was semi-automatically segmented from this region. Previously validated Monte Carlo models of two multidetector CT scanners were used, taking into account details about the source spectra, filtration, collimation and geometry of the scanner. TCM data were obtained from each patient's clinical scan and factored into the model to simulate the effects of TCM. For each patient model, two exams were simulated: a fixed tube current chest CT and a tube current modulated chest CT. X-ray photons were transported through the anatomy of the voxelized patient models, and radiation dose was tallied in the glandular breast tissue. The resulting doses from the tube current modulated simulations were compared to the results obtained from simulations performed using a fixed mA value. The average radiation dose to the glandular breast tissue from a fixed tube current scan across all patient models was 19 mGy. The average reduction in breast dose using the tube current modulated scan was 17%. Results were size dependent with smaller patients getting better dose reduction (up to 64% reduction) and larger patients getting a smaller reduction, and in some cases the dose actually increased when using tube current modulation (up to 41% increase). The results indicate that radiation dose to glandular breast tissue generally decreases with the use of tube current modulated CT acquisition, but that patient size (and in some cases patient positioning) may affect dose reduction.
Dong, Zhi-Hui; Yang, Zhi-Gang; Chen, Tian-Wu; Chu, Zhi-Gang; Deng, Wen; Shao, Heng
2011-01-01
Massive earthquakes are harmful to humankind. This study of a historical cohort aimed to investigate the difference between earthquake-related crush thoracic traumas and thoracic traumas unrelated to earthquakes using a multi-detector Computed Tomography (CT). We retrospectively compared an earthquake-exposed cohort of 215 thoracic trauma crush victims of the Sichuan earthquake to a cohort of 215 non-earthquake-related thoracic trauma patients, focusing on the lesions and coexisting injuries to the thoracic cage and the pulmonary parenchyma and pleura using a multi-detector CT. The incidence of rib fracture was elevated in the earthquake-exposed cohort (143 vs. 66 patients in the non-earthquake-exposed cohort, Risk Ratio (RR) = 2.2; p<0.001). Among these patients, those with more than 3 fractured ribs (106/143 vs. 41/66 patients, RR=1.2; p<0.05) or flail chest (45/143 vs. 11/66 patients, RR=1.9; p<0.05) were more frequently seen in the earthquake cohort. Earthquake-related crush injuries more frequently resulted in bilateral rib fractures (66/143 vs. 18/66 patients, RR= 1.7; p<0.01). Additionally, the incidence of non-rib fracture was higher in the earthquake cohort (85 vs. 60 patients, RR= 1.4; p<0.01). Pulmonary parenchymal and pleural injuries were more frequently seen in earthquake-related crush injuries (117 vs. 80 patients, RR=1.5 for parenchymal and 146 vs. 74 patients, RR = 2.0 for pleural injuries; p<0.001). Non-rib fractures, pulmonary parenchymal and pleural injuries had significant positive correlation with rib fractures in these two cohorts. Thoracic crush traumas resulting from the earthquake were life threatening with a high incidence of bony thoracic fractures. The ribs were frequently involved in bilateral and severe types of fractures, which were accompanied by non-rib fractures, pulmonary parenchymal and pleural injuries.
Dong, Zhi-hui; Yang, Zhi-gang; Chen, Tian-wu; Chu, Zhi-gang; Deng, Wen; Shao, Heng
2011-01-01
PURPOSE: Massive earthquakes are harmful to humankind. This study of a historical cohort aimed to investigate the difference between earthquake-related crush thoracic traumas and thoracic traumas unrelated to earthquakes using a multi-detector Computed Tomography (CT). METHODS: We retrospectively compared an earthquake-exposed cohort of 215 thoracic trauma crush victims of the Sichuan earthquake to a cohort of 215 non-earthquake-related thoracic trauma patients, focusing on the lesions and coexisting injuries to the thoracic cage and the pulmonary parenchyma and pleura using a multi-detector CT. RESULTS: The incidence of rib fracture was elevated in the earthquake-exposed cohort (143 vs. 66 patients in the non-earthquake-exposed cohort, Risk Ratio (RR) = 2.2; p<0.001). Among these patients, those with more than 3 fractured ribs (106/143 vs. 41/66 patients, RR = 1.2; p<0.05) or flail chest (45/143 vs. 11/66 patients, RR = 1.9; p<0.05) were more frequently seen in the earthquake cohort. Earthquake-related crush injuries more frequently resulted in bilateral rib fractures (66/143 vs. 18/66 patients, RR = 1.7; p<0.01). Additionally, the incidence of non-rib fracture was higher in the earthquake cohort (85 vs. 60 patients, RR = 1.4; p<0.01). Pulmonary parenchymal and pleural injuries were more frequently seen in earthquake-related crush injuries (117 vs. 80 patients, RR = 1.5 for parenchymal and 146 vs. 74 patients, RR = 2.0 for pleural injuries; p<0.001). Non-rib fractures, pulmonary parenchymal and pleural injuries had significant positive correlation with rib fractures in these two cohorts. CONCLUSIONS: Thoracic crush traumas resulting from the earthquake were life threatening with a high incidence of bony thoracic fractures. The ribs were frequently involved in bilateral and severe types of fractures, which were accompanied by non-rib fractures, pulmonary parenchymal and pleural injuries. PMID:21789386
Meenan, Christopher; Daly, Barry; Toland, Christopher; Nagy, Paul
2006-01-01
Rapid advances are changing the technology and applications of multidetector computed tomography (CT) scanners. The major increase in data associated with this new technology, however, breaks most commercial picture archiving and communication system (PACS) architectures by preventing them from delivering data in real time to radiologists and outside clinicians. We proposed a phased model for 3D workflow, installed a thin-slice archive and measured thin-slice data storage over a period of 5 months. A mean of 1,869 CT studies were stored per month, with an average of 643 images per study and a mean total volume of 588 GB/month. We also surveyed 48 radiologists to determine diagnostic use, impressions of thin-slice value, and requirements for retention times. The majority of radiologists thought thin slice was helpful for diagnosis and regularly used the application. Permanent storage of thin slice CT is likely to become best practice and a mission-critical pursuit for the health care enterprise.
An anatomical review of spinal cord blood supply.
Melissano, G; Bertoglio, L; Rinaldi, E; Leopardi, M; Chiesa, R
2015-10-01
Knowledge of the spinal cord (SC) vascular supply is important in patients undergoing procedures that involve the thoracic and thoracoabdominal aorta. However, the SC vasculature has a complex anatomy, and teaching is often based only on anatomical sketches with highly variable accuracy; historically, this has required a "leap of faith" on the part of aortic surgeons. Fortunately, this "leap of faith" is no longer necessary given recent breakthroughs in imaging technologies and postprocessing software. Imaging methods have expanded the non-invasive diagnostic ability to determine a patient's SC vascular pattern, particularly in detecting the presence and location of the artery of Adamkiewicz. CT is the imaging modality of choice for most patients with thoracic and thoracoabdominal aortic disease, proving especially useful in the determination of feasibility and planning of endovascular treatment. Thus the data set required for analysis of SC vascular anatomy is usually already available. We have concentrated our efforts on CT angiography, which offers particularly good imaging capabilities with state-of-the-art multidetector scanners. Multidetector row helical CT provides examinations of an extensive range in the craniocaudal direction with thin collimation in a short time interval, giving excellent temporal and spatial resolution. This paper provides examples of the SC vasculature imaging quality that can be obtained with 64 row scanners and appropriate postprocessing. Knowledge of the principal anatomical features of the SC blood supply of individual patients undergoing open or endovascular thoracoabdominal procedures has several potential benefits. For open surgery, analysis of the SC vasculature could tell us the aortic region that feeds the Adamkiewicz artery and thus needs to be reimplanted. For endovascular procedures, we can determine whether the stent-graft will cover the Adamkiewicz artery, thus avoiding unnecessary coverage. CT data can also be used to stratify risk of SC ischemia and guide the selective use of spinal cord injury prevention strategies.
Small-airway obstruction and emphysema in chronic obstructive pulmonary disease.
McDonough, John E; Yuan, Ren; Suzuki, Masaru; Seyednejad, Nazgol; Elliott, W Mark; Sanchez, Pablo G; Wright, Alexander C; Gefter, Warren B; Litzky, Leslie; Coxson, Harvey O; Paré, Peter D; Sin, Don D; Pierce, Richard A; Woods, Jason C; McWilliams, Annette M; Mayo, John R; Lam, Stephen C; Cooper, Joel D; Hogg, James C
2011-10-27
The major sites of obstruction in chronic obstructive pulmonary disease (COPD) are small airways (<2 mm in diameter). We wanted to determine whether there was a relationship between small-airway obstruction and emphysematous destruction in COPD. We used multidetector computed tomography (CT) to compare the number of airways measuring 2.0 to 2.5 mm in 78 patients who had various stages of COPD, as judged by scoring on the Global Initiative for Chronic Obstructive Lung Disease (GOLD) scale, in isolated lungs removed from patients with COPD who underwent lung transplantation, and in donor (control) lungs. MicroCT was used to measure the extent of emphysema (mean linear intercept), the number of terminal bronchioles per milliliter of lung volume, and the minimum diameters and cross-sectional areas of terminal bronchioles. On multidetector CT, in samples from patients with COPD, as compared with control samples, the number of airways measuring 2.0 to 2.5 mm in diameter was reduced in patients with GOLD stage 1 disease (P=0.001), GOLD stage 2 disease (P=0.02), and GOLD stage 3 or 4 disease (P<0.001). MicroCT of isolated samples of lungs removed from patients with GOLD stage 4 disease showed a reduction of 81 to 99.7% in the total cross-sectional area of terminal bronchioles and a reduction of 72 to 89% in the number of terminal bronchioles (P<0.001). A comparison of the number of terminal bronchioles and dimensions at different levels of emphysematous destruction (i.e., an increasing value for the mean linear intercept) showed that the narrowing and loss of terminal bronchioles preceded emphysematous destruction in COPD (P<0.001). These results show that narrowing and disappearance of small conducting airways before the onset of emphysematous destruction can explain the increased peripheral airway resistance reported in COPD. (Funded by the National Heart, Lung, and Blood Institute and others.).
Update on the imaging diagnosis of otosclerosis.
Gredilla Molinero, J; Mancheño Losa, M; Santamaría Guinea, N; Arévalo Galeano, N; Grande Bárez, M
2016-01-01
Otosclerosis is a primary osteodystrophy of the temporal bone that causes progressive conductive hearing loss. The diagnosis is generally clinical, but multidetector CT (MDCT), the imaging technique of choice, is sometimes necessary. The objective of this article is to systematically review the usefulness of imaging techniques for the diagnosis and postsurgical assessment of otosclerosis, fundamentally the role of MDCT, to decrease the surgical risk. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.
Interrupted Aortic Arch Associated with Absence of Left Common Carotid Artery: Imaging with MDCT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Onbas, Omer; Olgun, Hasim; Ceviz, Naci
2006-06-15
Interrupted aortic arch (IAA) is a rare severe congenital heart defect defined as complete luminal and anatomic discontinuity between ascending and descending aorta. Although its association with various congenital heart defects has been reported, absence of left common carotid artery (CCA) in patients with IAA has not been reported previously. We report a case of IAA associated with the absence of left CCA which was clearly shown on multidetector-row spiral CT.
Jinzaki, Masahiro; Okabe, Teruo; Endo, Ayaka; Kawamura, Akio; Koga, Seiko; Yamada, Minoru; Fukuda, Keiichi; Kuribayashi, Sachio
2012-01-01
To clarify multidetector computed tomography (MDCT) findings of attenuated plaque detected by intravascular ultrasound (IVUS). One hundred and fifty-four patients with stable angina underwent MDCT before IVUS. The attenuated plaque was identified in the targeted artery with IVUS, and the same artery was analyzed with MDCT for the presence of a high density area (HDA) >130 Hounsfield units (HU), and a low density area (LDA) <30 HU. A HDA in attenuated plaque was compared with that in calcified plaque. Ten attenuated plaques and 15 calcified plaques were identified in 9 of 154 patients (males=9, 66.2 ± 9.5 years). Eight of the 10 attenuated plaques and all 15 calcified plaques were accompanied with a HDA on MDCT. The HDA ranged from 174 to 667 HU (mean 389.0 ± 148.3 HU) in the 8 attenuated plaques, and from 545 to 1,205 HU (mean 920.9 ± 215.9 HU) in 15 calcified plaques. There was a significant difference in CT density of the HDA between the attenuated and calcified plaque (P<0.001). All attenuated plaques contained LDA <30 HU in the portions without HDA. MDCT has the ability to demonstrate attenuated plaque as the combination of HDA (approximately 400 HU on average) and LDA <30 HU. The HDA can be differentiated from calcified plaque by its lower CT density value.
Machida, Haruhiko; Yuhara, Toshiyuki; Tamura, Mieko; Numano, Tomokazu; Abe, Shinji; Sabol, John M; Suzuki, Shigeru; Ueno, Eiko
2012-06-01
Using an anthropomorphic phantom, we have investigated the feasibility of digital tomosynthesis (DT) of flat-panel detector (FPD) radiography to reduce radiation dose for sinonasal examination compared to multi-detector computed tomography (MDCT). A female Rando phantom was scanned covering frontal to maxillary sinus using the clinically routine protocol by both 64-detector CT (120 kV, 200 mAs, and 1.375-pitch) and DT radiography (80 kV, 1.0 mAs per projection, 60 projections, 40° sweep, and posterior-anterior projections). Glass dosimeters were used to measure the radiation dose to internal organs including the thyroid gland, brain, submandibular gland, and the surface dose at various sites including the eyes during those scans. We compared the radiation dose to those anatomies between both modalities. In DT radiography, the doses of the thyroid gland, brain, submandibular gland, skin, and eyes were 230 ± 90 μGy, 1770 ± 560 μGy, 1400 ± 80 μGy, 1160 ± 2100 μGy, and 112 ± 6 μGy, respectively. These doses were reduced to approximately 1/5, 1/8, 1/12, 1/17, and 1/290 of the respective MDCT dose. For sinonasal examinations, DT radiography enables dramatic reduction in radiation exposure and dose to the head and neck region, particularly to the lens of the eye. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Sun, Zhipeng; Fu, Kaiyuan; Zhang, Zuyan; Zhao, Yanping; Ma, Xuchen
2012-05-01
The aim of this study was to primarily investigate the usefulness of computerized tomographic (CT) fistulography in the diagnosis and management of branchial cleft fistulae and sinuses. Fifteen patients with confirmed branchial fistulae or sinuses who had undergone CT fistulography were included. The diagnoses were confirmed by clinical, radiologic, or histopathologic examinations. The internal openings, distribution, and neighboring relationship of the lesions presented by CT fistulography were analyzed to evaluate the usefulness in comparison with x-ray fistulography. Nine patients were diagnosed with first branchial fistulae or sinuses, 2 with second branchial fistulae, and 4 with third or fourth branchial fistulae. The presence and location of the lesions could be seen on x-ray fistulography. The distribution of the lesions, internal openings, and neighboring relationship with parotid gland, carotid sheath, and submandibular gland could be clearly demonstrated on CT cross-sectional or volume-rendering images. CT fistulography could provide valuable information and benefit surgical planning by demonstrating the courses of branchial anomalies in detail. Copyright © 2012 Elsevier Inc. All rights reserved.
Langenauer, J; Betschart, P; Hechelhammer, L; Güsewell, S; Schmid, H P; Engeler, D S; Abt, D; Zumstein, V
2018-05-29
To evaluate the predictive value of advanced non-contrasted computed tomography (NCCT) post-processing using novel CT-calculometry (CT-CM) parameters compared to established predictors of success of shock wave lithotripsy (SWL) for urinary calculi. NCCT post-processing was retrospectively performed in 312 patients suffering from upper tract urinary calculi who were treated by SWL. Established predictors such as skin to stone distance, body mass index, stone diameter or mean stone attenuation values were assessed. Precise stone size and shape metrics, 3-D greyscale measurements and homogeneity parameters such as skewness and kurtosis, were analysed using CT-CM. Predictive values for SWL outcome were analysed using logistic regression and receiver operating characteristics (ROC) statistics. Overall success rate (stone disintegration and no re-intervention needed) of SWL was 59% (184 patients). CT-CM metrics mainly outperformed established predictors. According to ROC analyses, stone volume and surface area performed better than established stone diameter, mean 3D attenuation value was a stronger predictor than established mean attenuation value, and parameters skewness and kurtosis performed better than recently emerged variation coefficient of stone density. Moreover, prediction of SWL outcome with 80% probability to be correct would be possible in a clearly higher number of patients (up to fivefold) using CT-CM-derived parameters. Advanced NCCT post-processing by CT-CM provides novel parameters that seem to outperform established predictors of SWL response. Implementation of these parameters into clinical routine might reduce SWL failure rates.
CT, MRI and PET imaging in peritoneal malignancy
Sahdev, Anju; Reznek, Rodney H.
2011-01-01
Abstract Imaging plays a vital role in the evaluation of patients with suspected or proven peritoneal malignancy. Nevertheless, despite significant advances in imaging technology and protocols, assessment of peritoneal pathology remains challenging. The combination of complex peritoneal anatomy, an extensive surface area that may host tumour deposits and the considerable overlap of imaging appearances of various peritoneal diseases often makes interpretation difficult. Contrast-enhanced multidetector computed tomography (MDCT) remains the most versatile tool in the imaging of peritoneal malignancy. However, conventional and emerging magnetic resonance imaging (MRI) and positron emission tomography (PET)/CT techniques offer significant advantages over MDCT in detection and surveillance. This article reviews established and new techniques in CT, MRI and PET imaging in both primary and secondary peritoneal malignancies and provides an overview of peritoneal anatomy, function and modes of disease dissemination with illustration of common sites and imaging features of peritoneal malignancy. PMID:21865109
Imaging in chronic obstructive pulmonary disease.
Shaker, Saher B; Dirksen, Asger; Bach, Karen S; Mortensen, Jann
2007-06-01
Chronic obstructive pulmonary disease (COPD) is divided into pulmonary emphysema and chronic bronchitis (CB). Emphysema is defined patho-anatomically as "permanent enlargement of airspaces distal to the terminal bronchiole, accompanied by the destruction of their walls, and without obvious fibrosis" (1). These lesions are readily identified and quantitated using computed tomography (CT), whereas the accompanying hyperinflation is best detected on plain chest X-ray, especially in advanced disease. The diagnosis of CB is clinical and relies on the presence of productive cough for 3 months in 2 or more successive years. The pathological changes of mucosal inflammation and bronchial wall thickening have been more difficult to identify with available imaging techniques. However, recent studies using Multi-detector row CT (MDCT) reported more reproducible assessment of air wall thickening.
Estimation of regional lung expansion via 3D image registration
NASA Astrophysics Data System (ADS)
Pan, Yan; Kumar, Dinesh; Hoffman, Eric A.; Christensen, Gary E.; McLennan, Geoffrey; Song, Joo Hyun; Ross, Alan; Simon, Brett A.; Reinhardt, Joseph M.
2005-04-01
A method is described to estimate regional lung expansion and related biomechanical parameters using multiple CT images of the lungs, acquired at different inflation levels. In this study, the lungs of two sheep were imaged utilizing a multi-detector row CT at different lung inflations in the prone and supine positions. Using the lung surfaces and the airway branch points for guidance, a 3D inverse consistent image registration procedure was used to match different lung volumes at each orientation. The registration was validated using a set of implanted metal markers. After registration, the Jacobian of the deformation field was computed to express regional expansion or contraction. The regional lung expansion at different pressures and different orientations are compared.
NASA Astrophysics Data System (ADS)
Gu, J.; Bednarz, B.; Caracappa, P. F.; Xu, X. G.
2009-05-01
The latest multiple-detector technologies have further increased the popularity of x-ray CT as a diagnostic imaging modality. There is a continuing need to assess the potential radiation risk associated with such rapidly evolving multi-detector CT (MDCT) modalities and scanning protocols. This need can be met by the use of CT source models that are integrated with patient computational phantoms for organ dose calculations. Based on this purpose, this work developed and validated an MDCT scanner using the Monte Carlo method, and meanwhile the pregnant patient phantoms were integrated into the MDCT scanner model for assessment of the dose to the fetus as well as doses to the organs or tissues of the pregnant patient phantom. A Monte Carlo code, MCNPX, was used to simulate the x-ray source including the energy spectrum, filter and scan trajectory. Detailed CT scanner components were specified using an iterative trial-and-error procedure for a GE LightSpeed CT scanner. The scanner model was validated by comparing simulated results against measured CTDI values and dose profiles reported in the literature. The source movement along the helical trajectory was simulated using the pitch of 0.9375 and 1.375, respectively. The validated scanner model was then integrated with phantoms of a pregnant patient in three different gestational periods to calculate organ doses. It was found that the dose to the fetus of the 3 month pregnant patient phantom was 0.13 mGy/100 mAs and 0.57 mGy/100 mAs from the chest and kidney scan, respectively. For the chest scan of the 6 month patient phantom and the 9 month patient phantom, the fetal doses were 0.21 mGy/100 mAs and 0.26 mGy/100 mAs, respectively. The paper also discusses how these fetal dose values can be used to evaluate imaging procedures and to assess risk using recommendations of the report from AAPM Task Group 36. This work demonstrates the ability of modeling and validating an MDCT scanner by the Monte Carlo method, as well as assessing fetal and organ doses by combining the MDCT scanner model and the pregnant patient phantom.
Automated Quantification of Pneumothorax in CT
Do, Synho; Salvaggio, Kristen; Gupta, Supriya; Kalra, Mannudeep; Ali, Nabeel U.; Pien, Homer
2012-01-01
An automated, computer-aided diagnosis (CAD) algorithm for the quantification of pneumothoraces from Multidetector Computed Tomography (MDCT) images has been developed. Algorithm performance was evaluated through comparison to manual segmentation by expert radiologists. A combination of two-dimensional and three-dimensional processing techniques was incorporated to reduce required processing time by two-thirds (as compared to similar techniques). Volumetric measurements on relative pneumothorax size were obtained and the overall performance of the automated method shows an average error of just below 1%. PMID:23082091
Osteochondral lesions about the ankle.
Naran, Ketan N; Zoga, Adam C
2008-11-01
Osteochondral lesions (OCLs) about the foot and ankle often manifest clinically as prolonged joint pain after trauma, often an ankle sprain, which is refractory to conventional, conservative therapeutic treatment. Noncontrast MR imaging is the standard of care imaging modality for diagnosing and classifying osteochondral lesions, but equivocal or difficult lesions can be assessed more specifically with direct MR arthrography or in conjunction with multidetector CT. Once an OCL has been identified, the imager should make every effort to determine whether it is stable or potentially unstable.
Computed tomography imaging and angiography - principles.
Kamalian, Shervin; Lev, Michael H; Gupta, Rajiv
2016-01-01
The evaluation of patients with diverse neurologic disorders was forever changed in the summer of 1973, when the first commercial computed tomography (CT) scanners were introduced. Until then, the detection and characterization of intracranial or spinal lesions could only be inferred by limited spatial resolution radioisotope scans, or by the patterns of tissue and vascular displacement on invasive pneumoencaphalography and direct carotid puncture catheter arteriography. Even the earliest-generation CT scanners - which required tens of minutes for the acquisition and reconstruction of low-resolution images (128×128 matrix) - could, based on density, noninvasively distinguish infarct, hemorrhage, and other mass lesions with unprecedented accuracy. Iodinated, intravenous contrast added further sensitivity and specificity in regions of blood-brain barrier breakdown. The advent of rapid multidetector row CT scanning in the early 1990s created renewed enthusiasm for CT, with CT angiography largely replacing direct catheter angiography. More recently, iterative reconstruction postprocessing techniques have made possible high spatial resolution, reduced noise, very low radiation dose CT scanning. The speed, spatial resolution, contrast resolution, and low radiation dose capability of present-day scanners have also facilitated dual-energy imaging which, like magnetic resonance imaging, for the first time, has allowed tissue-specific CT imaging characterization of intracranial pathology. © 2016 Elsevier B.V. All rights reserved.
Conley, David B.; Tan, Bruce; Bendok, Bernard R.; Batjer, H. Hunt; Chandra, Rakesh; Sidle, Douglas; Rahme, Rudy J.; Adel, Joseph G.; Fishman, Andrew J.
2011-01-01
Precise and safe management of complex skull base lesions can be enhanced by intraoperative computed tomography (CT) scanning. Surgery in these areas requires real-time feedback of anatomic landmarks. Several portable CT scanners are currently available. We present a comparison of our clinical experience with three portable scanners in skull base and craniofacial surgery. We present clinical case series and the participants were from the Northwestern Memorial Hospital. Three scanners are studied: one conventional multidetector CT (MDCT), two digital flat panel cone-beam CT (CBCT) devices. Technical considerations, ease of use, image characteristics, and integration with image guidance are presented for each device. All three scanners provide good quality images. Intraoperative scanning can be used to update the image guidance system in real time. The conventional MDCT is unique in its ability to resolve soft tissue. The flat panel CBCT scanners generally emit lower levels of radiation and have less metal artifact effect. In this series, intraoperative CT scanning was technically feasible and deemed useful in surgical decision-making in 75% of patients. Intraoperative portable CT scanning has significant utility in complex skull base surgery. This technology informs the surgeon of the precise extent of dissection and updates intraoperative stereotactic navigation. PMID:22470270
[Evaluation of Organ Dose Estimation from Indices of CT Dose Using Dose Index Registry].
Iriuchijima, Akiko; Fukushima, Yasuhiro; Ogura, Akio
Direct measurement of each patient organ dose from computed tomography (CT) is not possible. Most methods to estimate patient organ dose is using Monte Carlo simulation with dedicated software. However, dedicated software is too expensive for small scale hospitals. Not every hospital can estimate organ dose with dedicated software. The purpose of this study was to evaluate the simple method of organ dose estimation using some common indices of CT dose. The Monte Carlo simulation software Radimetrics (Bayer) was used for calculating organ dose and analysis relationship between indices of CT dose and organ dose. Multidetector CT scanners were compared with those from two manufactures (LightSpeed VCT, GE Healthcare; SOMATOM Definition Flash, Siemens Healthcare). Using stored patient data from Radimetrics, the relationships between indices of CT dose and organ dose were indicated as each formula for estimating organ dose. The accuracy of estimation method of organ dose was compared with the results of Monte Carlo simulation using the Bland-Altman plots. In the results, SSDE was the feasible index for estimation organ dose in almost organs because it reflected each patient size. The differences of organ dose between estimation and simulation were within 23%. In conclusion, our estimation method of organ dose using indices of CT dose is convenient for clinical with accuracy.
Experimental benchmarking of a Monte Carlo dose simulation code for pediatric CT
NASA Astrophysics Data System (ADS)
Li, Xiang; Samei, Ehsan; Yoshizumi, Terry; Colsher, James G.; Jones, Robert P.; Frush, Donald P.
2007-03-01
In recent years, there has been a desire to reduce CT radiation dose to children because of their susceptibility and prolonged risk for cancer induction. Concerns arise, however, as to the impact of dose reduction on image quality and thus potentially on diagnostic accuracy. To study the dose and image quality relationship, we are developing a simulation code to calculate organ dose in pediatric CT patients. To benchmark this code, a cylindrical phantom was built to represent a pediatric torso, which allows measurements of dose distributions from its center to its periphery. Dose distributions for axial CT scans were measured on a 64-slice multidetector CT (MDCT) scanner (GE Healthcare, Chalfont St. Giles, UK). The same measurements were simulated using a Monte Carlo code (PENELOPE, Universitat de Barcelona) with the applicable CT geometry including bowtie filter. The deviations between simulated and measured dose values were generally within 5%. To our knowledge, this work is one of the first attempts to compare measured radial dose distributions on a cylindrical phantom with Monte Carlo simulated results. It provides a simple and effective method for benchmarking organ dose simulation codes and demonstrates the potential of Monte Carlo simulation for investigating the relationship between dose and image quality for pediatric CT patients.
Ugurel, M S; Battal, B; Bozlar, U; Nural, M S; Tasar, M; Ors, F; Saglam, M; Karademir, I
2010-08-01
The purpose of our investigation was to determine the anatomical variations in the coeliac trunk-hepatic arterial system and the renal arteries in patients who underwent multidetector CT (MDCT) angiography of the abdominal aorta for various reasons. A total of 100 patients were analysed retrospectively. The coeliac trunk, hepatic arterial system and renal arteries were analysed individually and anatomical variations were recorded. Statistical analysis of the relationship between hepatocoeliac variations and renal artery variations was performed using a chi(2) test. There was a coeliac trunk trifurcation in 89% and bifurcation in 8% of the cases. Coeliac trunk was absent in 1%, a hepatosplenomesenteric trunk was seen in 1% and a splenomesenteric trunk was present in 1%. Hepatic artery variation was present in 48% of patients. Coeliac trunk and/or hepatic arterial variation was present in 23 (39.7%) of the 58 patients with normal renal arteries, and in 27 (64.3%) of the 42 patients with accessory renal arteries. There was a statistically significant correlation between renal artery variations and coeliac trunk-hepatic arterial system variations (p = 0.015). MDCT angiography permits a correct and detailed evaluation of hepatic and renal vascular anatomy. The prevalence of variations in the coeliac trunk and/or hepatic arteries is increased in people with accessory renal arteries. For that reason, when undertaking angiographic examinations directed towards any single organ, the possibility of variations in the vascular structure of other organs should be kept in mind.
Qi, Rui; Zhou, Xiangping; Yu, Jianqun; Li, Zhenlin
2014-04-01
This study aims to explore the inferior adhesion of the renal fascia (RF), and the inferior connectivity of the perirenal spaces (PS) with multidetector computed tomography (MDCT), and to investigate the diagnostic value of CT for showing this anatomy. From May to July 2012, eighty-two patients with acute pancreatitis presented in our hospital were enrolled into this study and underwent contrast-enhanced CT scans. All the image data were used to perform three dimensional reconstruction to show the inferior attachment of RF and the inferior connectivity of PS. The fusion of anterior renal fascia (ARF) and posterior renal fascia (PRF) next to the plane of iliac fossa were found on the left in 71.95% (59/82) cases, and on the right in 75.61% (62/82). In these cases, bilateral perirenal spaces, and anterior and posterior pararenal spaces were not found to be connected with each other. No fusion of ARF and PRF below the level of bilateral kidneys occurred on the left side in 28.05% (23/82) cases and on the right side in 24.39% (20/82). In these patients, the PS extended to the extraperitoneal space of the pelvic cavity and further to the inguinal region, and bilateral anterior and posterior pararenal spaces were not found to be connected with each other. Three-dimensional reconstruction on contrast-enhanced MDCT could be a valuable procedure for depicting inferior attachment of RF, and the inferior connectivity of PS.
Multidetector CT of Surgically Proven Blunt Bowel and Mesenteric Injury.
Bates, David D B; Wasserman, Michael; Malek, Anita; Gorantla, Varun; Anderson, Stephan W; Soto, Jorge A; LeBedis, Christina A
2017-01-01
Blunt traumatic injury is one of the leading causes of morbidity and mortality in the United States. Unintentional injury represents the leading cause of death in the United States for all persons between the ages of 1 and 44 years. In the setting of blunt abdominal trauma, the reported rate of occurrence of bowel and mesenteric injuries ranges from 1% to 5%. Despite the relatively low rate of blunt bowel and mesenteric injury in patients with abdominal and pelvic trauma, delays in diagnosis are associated with increased rates of sepsis, a prolonged course in the intensive care unit, and increased mortality. During the past 2 decades, as multidetector computed tomography (CT) has emerged as an essential tool in emergency radiology, several direct and indirect imaging features have been identified that are associated with blunt bowel and mesenteric injury. The imaging findings in cases of blunt bowel and mesenteric injury can be subtle and may be seen in the setting of multiple complex injuries, such as multiple solid-organ injuries and spinal fractures. Familiarity with the various imaging features of blunt bowel and mesenteric injury, as well as an understanding of their clinical importance with regard to the care of the patient, is essential to making a timely diagnosis. Once radiologists are familiar with the spectrum of findings of blunt bowel and mesenteric injury, they will be able to make timely diagnoses that will lead to improved patient outcomes. © RSNA, 2017.
Carlson, Matthew L; Leng, Shuai; Diehn, Felix E; Witte, Robert J; Krecke, Karl N; Grimes, Josh; Koeller, Kelly K; Bruesewitz, Michael R; McCollough, Cynthia H; Lane, John I
2017-08-01
A new generation 192-slice multi-detector computed tomography (MDCT) clinical scanner provides enhanced image quality and superior electrode localization over conventional MDCT. Currently, accurate and reliable cochlear implant electrode localization using conventional MDCT scanners remains elusive. Eight fresh-frozen cadaveric temporal bones were implanted with full-length cochlear implant electrodes. Specimens were subsequently scanned with conventional 64-slice and new generation 192-slice MDCT scanners utilizing ultra-high resolution modes. Additionally, all specimens were scanned with micro-CT to provide a reference criterion for electrode position. Images were reconstructed according to routine temporal bone clinical protocols. Three neuroradiologists, blinded to scanner type, reviewed images independently to assess resolution of individual electrodes, scalar localization, and severity of image artifact. Serving as the reference standard, micro-CT identified scalar crossover in one specimen; imaging of all remaining cochleae demonstrated complete scala tympani insertions. The 192-slice MDCT scanner exhibited improved resolution of individual electrodes (p < 0.01), superior scalar localization (p < 0.01), and reduced blooming artifact (p < 0.05), compared with conventional 64-slice MDCT. There was no significant difference between platforms when comparing streak or ring artifact. The new generation 192-slice MDCT scanner offers several notable advantages for cochlear implant imaging compared with conventional MDCT. This technology provides important feedback regarding electrode position and course, which may help in future optimization of surgical technique and electrode design.
Richtberg, Samantha; Jakob, Marion; Höfling, Volkmar; Weck, Florian
2017-06-01
Psychotherapy for hypochondriasis has greatly improved over the last decades and cognitive-behavioral treatments are most promising. However, research on predictors of treatment outcome for hypochondriasis is rare. Possible predictors of treatment outcome in cognitive therapy (CT) and exposure therapy (ET) for hypochondriasis were investigated. Characteristics and behaviors of 75 patients were considered as possible predictors: sociodemographic variables (sex, age, and cohabitation); psychopathology (pretreatment hypochondriacal symptoms, comorbid mental disorders, and levels of depression, anxiety, and somatic symptoms); and patient in-session interpersonal behavior. Severity of pretreatment hypochondriacal symptoms, comorbid mental disorders, and patient in-session interpersonal behavior were significant predictors in multiple hierarchical regression analyses. Interactions between the predictors and the treatment (CT or ET) were not found. In-session interpersonal behavior is an important predictor of outcome. Furthermore, there are no specific contraindications to treating hypochondriasis with CT or ET. © 2016 Wiley Periodicals, Inc.
Radiological protection in computed tomography and cone beam computed tomography.
Rehani, M M
2015-06-01
The International Commission on Radiological Protection (ICRP) has sustained interest in radiological protection in computed tomography (CT), and ICRP Publications 87 and 102 focused on the management of patient doses in CT and multi-detector CT (MDCT) respectively. ICRP forecasted and 'sounded the alarm' on increasing patient doses in CT, and recommended actions for manufacturers and users. One of the approaches was that safety is best achieved when it is built into the machine, rather than left as a matter of choice for users. In view of upcoming challenges posed by newer systems that use cone beam geometry for CT (CBCT), and their widened usage, often by untrained users, a new ICRP task group has been working on radiological protection issues in CBCT. Some of the issues identified by the task group are: lack of standardisation of dosimetry in CBCT; the false belief within the medical and dental community that CBCT is a 'light', low-dose CT whereas mobile CBCT units and newer applications, particularly C-arm CT in interventional procedures, involve higher doses; lack of training in radiological protection among clinical users; and lack of dose information and tracking in many applications. This paper provides a summary of approaches used in CT and MDCT, and preliminary information regarding work just published for radiological protection in CBCT. © The International Society for Prosthetics and Orthotics Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
NASA Astrophysics Data System (ADS)
Nishimaru, Eiji; Ichikawa, Katsuhiro; Okita, Izumi; Ninomiya, Yuuji; Tomoshige, Yukihiro; Kurokawa, Takehiro; Ono, Yutaka; Nakamura, Yuko; Suzuki, Masayuki
2008-03-01
Recently, several kinds of post-processing image filters which reduce the noise of computed tomography (CT) images have been proposed. However, these image filters are mostly for adults. Because these are not very effective in small (< 20 cm) display fields of view (FOV), we cannot use them for pediatric body images (e.g., premature babies and infant children). We have developed a new noise reduction filter algorithm for pediatric body CT images. This algorithm is based on a 3D post-processing in which the output pixel values are calculated by nonlinear interpolation in z-directions on original volumetric-data-sets. This algorithm does not need the in-plane (axial plane) processing, so the spatial resolution does not change. From the phantom studies, our algorithm could reduce SD up to 40% without affecting the spatial resolution of x-y plane and z-axis, and improved the CNR up to 30%. This newly developed filter algorithm will be useful for the diagnosis and radiation dose reduction of the pediatric body CT images.
NASA Astrophysics Data System (ADS)
Tian, Xiaoyu; Li, Xiang; Segars, W. Paul; Frush, Donald P.; Samei, Ehsan
2012-03-01
The purpose of this work was twofold: (a) to estimate patient- and cohort-specific radiation dose and cancer risk index for abdominopelvic computer tomography (CT) scans; (b) to evaluate the effects of patient anatomical characteristics (size, age, and gender) and CT scanner model on dose and risk conversion coefficients. The study included 100 patient models (42 pediatric models, 58 adult models) and multi-detector array CT scanners from two commercial manufacturers (LightSpeed VCT, GE Healthcare; SOMATOM Definition Flash, Siemens Healthcare). A previously-validated Monte Carlo program was used to simulate organ dose for each patient model and each scanner, from which DLP-normalized-effective dose (k factor) and DLP-normalized-risk index values (q factor) were derived. The k factor showed exponential decrease with increasing patient size. For a given gender, q factor showed exponential decrease with both increasing patient size and patient age. The discrepancies in k and q factors across scanners were on average 8% and 15%, respectively. This study demonstrates the feasibility of estimating patient-specific organ dose and cohort-specific effective dose and risk index in abdominopelvic CT requiring only the knowledge of patient size, gender, and age.
Trabecular bone class mapping across resolutions: translating methods from HR-pQCT to clinical CT
NASA Astrophysics Data System (ADS)
Valentinitsch, Alexander; Fischer, Lukas; Patsch, Janina M.; Bauer, Jan; Kainberger, Franz; Langs, Georg; DiFranco, Matthew
2015-03-01
Quantitative assessment of 3D bone microarchitecture in high-resolution peripheral quantitative computed tomography (HR-pQCT) has shown promise in fracture risk assessment and biomechanics, but is limited to the distal radius and tibia. Trabecular microarchitecture classes (TMACs), based on voxel-wise clustering texture and structure tensor features in HRpQCT, is extended in this paper to quantify trabecular bone classes in clinical multi-detector CT (MDCT) images. Our comparison of TMACs in 12 cadaver radii imaged using both HRpQCT and MDCT yields a mean Dice score of up to 0.717+/-0.40 and visually concordant bone quality maps. Further work to develop clinically viable bone quantitative imaging using HR-pQCT validation could have a significant impact on overall bone health assessment.
Pessis, Eric; Campagna, Raphaël; Sverzut, Jean-Michel; Bach, Fabienne; Rodallec, Mathieu; Guerini, Henri; Feydy, Antoine; Drapé, Jean-Luc
2013-01-01
With arthroplasty being increasingly used to relieve joint pain, imaging of patients with metal implants can represent a significant part of the clinical work load in the radiologist's daily practice. Computed tomography (CT) plays an important role in the postoperative evaluation of patients who are suspected of having metal prosthesis-related problems such as aseptic loosening, bone resorption or osteolysis, infection, dislocation, metal hardware failure, or periprosthetic bone fracture. Despite advances in detector technology and computer software, artifacts from metal implants can seriously degrade the quality of CT images, sometimes to the point of making them diagnostically unusable. Several factors may help reduce the number and severity of artifacts at multidetector CT, including decreasing the detector collimation and pitch, increasing the kilovolt peak and tube charge, and using appropriate reconstruction algorithms and section thickness. More recently, dual-energy CT has been proposed as a means of reducing beam-hardening artifacts. The use of dual-energy CT scanners allows the synthesis of virtual monochromatic spectral (VMS) images. Monochromatic images depict how the imaged object would look if the x-ray source produced x-ray photons at only a single energy level. For this reason, VMS imaging is expected to provide improved image quality by reducing beam-hardening artifacts.
Gavrielides, Marios A.; Kinnard, Lisa M.; Myers, Kyle J.; Peregoy, Jennifer; Pritchard, William F.; Zeng, Rongping; Esparza, Juan; Karanian, John; Petrick, Nicholas
2010-01-01
A number of interrelated factors can affect the precision and accuracy of lung nodule size estimation. To quantify the effect of these factors, we have been conducting phantom CT studies using an anthropomorphic thoracic phantom containing a vasculature insert to which synthetic nodules were inserted or attached. Ten repeat scans were acquired on different multi-detector scanners, using several sets of acquisition and reconstruction protocols and various nodule characteristics (size, shape, density, location). This study design enables both bias and variance analysis for the nodule size estimation task. The resulting database is in the process of becoming publicly available as a resource to facilitate the assessment of lung nodule size estimation methodologies and to enable comparisons between different methods regarding measurement error. This resource complements public databases of clinical data and will contribute towards the development of procedures that will maximize the utility of CT imaging for lung cancer screening and tumor therapy evaluation. PMID:20640011
[Preoperative imaging/operation planning for liver surgery].
Schoening, W N; Denecke, T; Neumann, U P
2015-12-01
The currently established standard for planning liver surgery is multistage contrast media-enhanced multidetector computed tomography (CM-CT), which as a rule enables an appropriate resection planning, e.g. a precise identification and localization of primary and secondary liver tumors as well as the anatomical relation to extrahepatic and/or intrahepatic vascular and biliary structures. Furthermore, CM-CT enables the measurement of tumor volume, total liver volume and residual liver volume after resection. Under the condition of normal liver function a residual liver volume of 25 % is nowadays considered sufficient and safe. Recent studies in patients with liver metastases of colorectal cancer showed a clear staging advantage of contrast media-enhanced magnetic resonance imaging (CM-MRI) versus CM-CT. In addition, most recent data showed that the use of liver-specific MRI contrast media further increases the sensitivity and specificity of detection of liver metastases. This imaging technology seems to lead closer to the ideal "one stop shopping" diagnostic tool in preoperative planning of liver resection.
Asayama, Yoshiki; Nishie, Akihiro; Ishigami, Kousei; Ushijima, Yasuhiro; Takayama, Yukihisa; Okamoto, Daisuke; Fujita, Nobuhiro; Ohtsuka, Takao; Yoshizumi, Tomoharu; Aishima, Shinichi; Oda, Yoshinao; Honda, Hiroshi
2017-06-01
To determine whether washout characteristics of dynamic contrast-enhanced computed tomography (CT) could predict survival in patients with extrahepatic cholangiocarcinoma (EHC). This study collected 46 resected cases. All cases were examined by dynamic contrast study on multidetector-row CT. Region-of-interest measurements were obtained at the non-enhanced, portal venous phase and delayed phase in the tumour and were used to calculate the washout ratio as follows: [(attenuation value at portal venous phase CT - attenuation value at delayed enhanced CT)/(attenuation value at portal venous phase CT - attenuation value at unenhanced CT)] × 100. On the basis of the median washout ratio, we classified the cases into two groups, a high-washout group and low-washout group. Associations between overall survival and various factors including washout rates were analysed. The median washout ratio was 29.4 %. Univariate analysis revealed that a lower washout ratio, venous invasion, lymphatic permeation and lymph node metastasis were associated with shorter survival. Multivariate analysis identified the lower washout ratio as an independent prognostic factor (hazard ratio, 3.768; p value, 0.027). The washout ratio obtained from the contrast-enhanced CT may be a useful imaging biomarker for the prediction of survival of patients with EHC. • Dynamic contrast study can evaluate the aggressiveness of extrahepatic cholangiocarcinoma. • A lower washout ratio was an independent prognostic factor for overall survival. • CT can predict survival and inform decisions on surgical options or chemotherapy.
Ippolito, Davide; Drago, Silvia Girolama; Franzesi, Cammillo Talei; Fior, Davide; Sironi, Sandro
2016-01-01
AIM: To assess the diagnostic accuracy of multidetector-row computed tomography (MDCT) as compared with conventional magnetic resonance imaging (MRI), in identifying mesorectal fascia (MRF) invasion in rectal cancer patients. METHODS: Ninety-one patients with biopsy proven rectal adenocarcinoma referred for thoracic and abdominal CT staging were enrolled in this study. The contrast-enhanced MDCT scans were performed on a 256 row scanner (ICT, Philips) with the following acquisition parameters: tube voltage 120 KV, tube current 150-300 mAs. Imaging data were reviewed as axial and as multiplanar reconstructions (MPRs) images along the rectal tumor axis. MRI study, performed on 1.5 T with dedicated phased array multicoil, included multiplanar T2 and axial T1 sequences and diffusion weighted images (DWI). Axial and MPR CT images independently were compared to MRI and MRF involvement was determined. Diagnostic accuracy of both modalities was compared and statistically analyzed. RESULTS: According to MRI, the MRF was involved in 51 patients and not involved in 40 patients. DWI allowed to recognize the tumor as a focal mass with high signal intensity on high b-value images, compared with the signal of the normal adjacent rectal wall or with the lower tissue signal intensity background. The number of patients correctly staged by the native axial CT images was 71 out of 91 (41 with involved MRF; 30 with not involved MRF), while by using the MPR 80 patients were correctly staged (45 with involved MRF; 35 with not involved MRF). Local tumor staging suggested by MDCT agreed with those of MRI, obtaining for CT axial images sensitivity and specificity of 80.4% and 75%, positive predictive value (PPV) 80.4%, negative predictive value (NPV) 75% and accuracy 78%; while performing MPR the sensitivity and specificity increased to 88% and 87.5%, PPV was 90%, NPV 85.36% and accuracy 88%. MPR images showed higher diagnostic accuracy, in terms of MRF involvement, than native axial images, as compared to the reference magnetic resonance images. The difference in accuracy was statistically significant (P = 0.02). CONCLUSION: New generation CT scanner, using high resolution MPR images, represents a reliable diagnostic tool in assessment of loco-regional and whole body staging of advanced rectal cancer, especially in patients with MRI contraindications. PMID:27239115
An evaluation of the use of oral contrast media in abdominopelvic CT.
Buttigieg, Erica Lauren; Grima, Karen Borg; Cortis, Kelvin; Soler, Sandro Galea; Zarb, Francis
2014-11-01
To evaluate the diagnostic efficacy of different oral contrast media (OCM) for abdominopelvic CT examinations performed for follow-up general oncological indications. The objectives were to establish anatomical image quality criteria for abdominopelvic CT; use these criteria to evaluate and compare image quality using positive OCM, neutral OCM and no OCM; and evaluate possible benefits for the medical imaging department. Forty-six adult patients attending a follow-up abdominopelvic CT for general oncological indications and who had a previous abdominopelvic CT with positive OCM (n = 46) were recruited and prospectively placed into either the water (n = 25) or no OCM (n = 21) group. Three radiologists performed absolute visual grading analysis (VGA) to assess image quality by grading the fulfilment of 24 anatomical image quality criteria. Visual grading characteristics (VGC) analysis of the data showed comparable image quality with regards to reproduction of abdominal structures, bowel discrimination, presence of artefacts, and visualization of the amount of intra-abdominal fat for the three OCM protocols. All three OCM protocols provided similar image quality for follow-up abdominopelvic CT for general oncological indications. • Positive oral contrast media are routinely used for abdominopelvic multidetector computed tomography • Experimental study comparing image quality using three different oral contrast materials • Three different oral contrast materials result in comparable CT image quality • Benefits for patients and medical imaging department.
ERIC Educational Resources Information Center
Strunk, Daniel R.; Cooper, Andrew A.; Ryan, Elizabeth T.; DeRubeis, Robert J.; Hollon, Steven D.
2012-01-01
Objective: Previous studies of cognitive therapy (CT) for depression have examined therapist adherence and the therapeutic alliance as predictors of subsequent symptom change. However, little is known about these CT process variables when CT is delivered in combination with antidepressant medication. Method: In a sample of 176 depressed…
Dewailly, Marion; Rémy-Jardin, Martine; Duhamel, Alain; Faivre, Jean-Baptiste; Pontana, François; Deken, Valérie; Bakai, Anne-Marie; Remy, Jacques
2010-01-01
To evaluate the performance of a computer-aided detection (CAD) system for diagnosing peripheral acute pulmonary embolism (PE) with a 64-slice multi-detector row computed tomography (CT). Two radiologists investigated the accuracy of a software aimed at detecting peripheral clots (PECAD prototype, version 7; Siemens Medical Systems, Forchheim, Germany) by applying this tool for the analysis of the pulmonary arterial bed of 74 CT angiograms obtained with 64-slice dual-source CT (Definition; Siemens Medical Systems). These cases were retrospectively selected from a database of CT studies performed on the same CT unit, with a similar collimation (64 x 0.6 mm) and similar injection protocols. Patient selection was based on a variety of (1) scanning conditions, namely, nongated (n = 30), electrocardiography-gated (n = 30), and dual-energy CT angiograms (n = 14), and (2) image quality (IQ), namely, scans of excellent IQ (n = 53) and lower IQ due to lower levels of arterial enhancement and/or presence of noise (n = 21). The standard of truth was based on the 2 radiologists' consensus reading and the results of CAD. The software detected 80 of 93 peripheral clots present in the 21 patients (42 segmental and 38 subsegmental clots). The overall sensitivity (95% confidence interval) of the CAD tool was 86% (77%-92%) for detecting peripheral clots, 78% (64.5%-88%) at the segmental level and 97% (85.5%-99.9%) at the subsegmental level. Assuming normal vascular anatomy with 20 segmental and 40 subsegmental arteries, overall specificity and positive and negative predictive values (95% confidence interval) of the software were 91.8% (91%-92.6%), 18.4% (15%-22.4%), and 99.7% (99.5%-99.8%), respectively. A mean of 5.4 false positives was found per patient (total, 354 false positives), mainly linked to the presence of perivascular connective tissue (n = 119; 34%) and perivascular airspace consolidation (n = 97; 27%). The sensitivities (95% confidence interval) for the CAD tool were 91% (69.8%-99.3%) for dual-energy, 87% (59.3%-93.2%) for electrocardiography-gated, and 87% (73.5%-95.3%) for nongated scans (P > 0.05). No significant difference was found in the sensitivity of the CAD software when comparing the scans according to the scanning conditions and image quality. The evaluated CAD software has a good sensitivity in detecting peripheral PE, which is not influenced by the scanning conditions or the overall image quality.
Holalkere, N-S; Matthes, K; Kalva, S P; Brugge, W R; Sahani, D V
2011-01-01
Objective In this study we aimed to assess the image quality and degree of vascular enhancement using low-concentration contrast media (LCCM) (300 mg I ml–1) and high-concentration contrast media (HCCM) (370 mg I ml–1) on 64-slice multidetector row CT (MDCT) abdominal CT angiography (CTA). In addition, we aimed to study the feasibility of using HCCM with a reduced total iodine dose. Methods CTA of the abdomen on a 64-slice MDCT was performed on 15 anaesthetised pigs. Study pigs were divided into three groups of five each based on the iodine concentration and dose received: Group A (LCCM; 300 mg I ml–1), Group B (HCCM; 370 mg I ml–1) and Group C HCCM with 20% less iodine dose. The total iodine injected was kept constant (600 mg kg–1) in Groups A and B. Qualitative and quantitative analyses were performed to study and compare each group for image quality, visibility of the branch order of the superior mesenteric artery (SMA), artefacts, degree of enhancement in the aorta and main stem arteries and uniformity of enhancement in the aorta. Groups were compared using the analysis of variance test. Results The image quality of 64-slice MDCT angiography was excellent with a mean score of 4.63 and confident visualisation of the third to fifth order branches of the SMA in all groups. Group B demonstrated superior vascular enhancement, as compared with Groups A and C (p≤0.05). Uniform aortic enhancement was achieved with the use of LCCM and HCCM with 20% less iodine dose. Conclusion 64-slice MDCT angiography of the abdomen was of excellent quality. HCCM improves contrast enhancement and overall CTA image quality and allows the iodine dose to be reduced. PMID:21081582
Epicardial adipose tissue as a predictor of coronary artery disease in asymptomatic subjects.
Bachar, Gil N; Dicker, Dror; Kornowski, Ran; Atar, Eli
2012-08-15
This study sought to elucidate the relation between epicardial adipose tissue (EAT) thickness measured by multidetector computed tomography and presence of coronary artery atherosclerosis. Recent studies have suggested that fat disposition in visceral organs and epicardial tissue could serve as a predictor of coronary artery disease (CAD). The sample included 190 asymptomatic subjects with ≥ 1 cardiovascular risk factor who were referred for cardiac computed tomographic angiography. Body mass index, blood pressure, fasting glucose level, and lipid profile were measured. Multidetector computed tomographic results were analyzed for atherosclerosis burden, calcium Agatston score, and EAT thickness: mean EAT values were 3.54 ± 1.59 mm in patients with atherosclerosis and 1.85 ± 1.28 mm in patients without atherosclerosis (p <0.001). On receiver operating characteristic analysis, an EAT value ≥ 2.4 mm predicted the presence of significant (>50% diameter) coronary artery stenosis. There was a significant difference in EAT values between patients with and without metabolic syndrome (2.58 ± 1.63 vs 2.04 ± 1.46 mm, p <0.05) and between patients with a calcium score >400 and <400 (3.38 ± 1.58 vs 2.02 ± 1.42 mm, p <0.0001). In conclusion, asymptomatic patients with CAD have significantly more EAT than patients without CAD. An EAT thickness of 2.4 mm is the optimal cutoff for prediction of presence of significant CAD. Copyright © 2012 Elsevier Inc. All rights reserved.
Luo, Mingxu; Song, Hongmei; Liu, Gang; Lin, Yikai; Luo, Lintao; Zhou, Xin; Chen, Bo
2017-10-13
The diagnostic values of diffusion weighted imaging (DWI) and 18 F-fluorodeoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT) for N-staging of gastric cancer (GC) were identified and compared. After a systematic search to identify relevant articles, meta-analysis was used to summarize the sensitivities, specificities, and areas under curves (AUCs) for DWI and PET/CT. To better understand the diagnostic utility of DWI and PET/CT for N-staging, the performance of multi-detector computed tomography (MDCT) was used as a reference. Fifteen studies were analyzed. The pooled sensitivity, specificity, and AUC with 95% confidence intervals of DWI were 0.79 (0.73-0.85), 0.69 (0.61-0.77), and 0.81 (0.77-0.84), respectively. For PET/CT, the corresponding values were 0.52 (0.39-0.64), 0.88 (0.61-0.97), and 0.66 (0.62-0.70), respectively. Comparison of the two techniques revealed DWI had higher sensitivity and AUC, but no difference in specificity. DWI exhibited higher sensitivity but lower specificity than MDCT, and 18 F-FDG PET/CT had lower sensitivity and equivalent specificity. Overall, DWI performed better than 18 F-FDG PET/CT for preoperative N-staging in GC. When the efficacy of MDCT was taken as a reference, DWI represented a complementary imaging technique, while 18 F-FDG PET/CT had limited utility for preoperative N-staging.
Kikuchi, Yasuka; Oyama-Manabe, Noriko; Naya, Masanao; Manabe, Osamu; Tomiyama, Yuuki; Sasaki, Tsukasa; Katoh, Chietsugu; Kudo, Kohsuke; Tamaki, Nagara; Shirato, Hiroki
2014-07-01
This study introduces a method to calculate myocardium blood flow (MBF) and coronary flow reserve (CFR) using the relatively low-dose dynamic 320-row multi-detector computed tomography (MDCT), validates the method against (15)O-H₂O positron-emission tomography (PET) and assesses the CFRs of coronary artery disease (CAD) patients. Thirty-two subjects underwent both dynamic CT perfusion (CTP) and PET perfusion imaging at rest and during pharmacological stress. In 12 normal subjects (pilot group), the calculation method for MBF and CFR was established. In the other 13 normal subjects (validation group), MBF and CFR obtained by dynamic CTP and PET were compared. Finally, the CFRs obtained by dynamic CTP and PET were compared between the validation group and CAD patients (n = 7). Correlation between MBF of MDCT and PET was strong (r = 0.95, P < 0.0001). CFR showed good correlation between dynamic CTP and PET (r = 0.67, P = 0.0126). CFRCT in the CAD group (2.3 ± 0.8) was significantly lower than that in the validation group (5.2 ± 1.8) (P = 0.0011). We established a method for measuring MBF and CFR with the relatively low-dose dynamic MDCT. Lower CFR was well demonstrated in CAD patients by dynamic CTP. • MBF and CFR can be calculated using dynamic CTP with 320-row MDCT. • MBF and CFR showed good correlation between dynamic CTP and PET. • Lower CFR was well demonstrated in CAD patients by dynamic CTP.
Furlan, A; Marin, D; Vanzulli, A; Patera, G Palermo; Ronzoni, A; Midiri, M; Bazzocchi, M; Lagalla, R; Brancatelli, G
2011-01-01
Objectives Our aim was to compare retrospectively hepatic venous and delayed phase images for the detection of tumour washout during multiphasic multidetector row CT (MDCT) of the liver in patients with hepatocellular carcinoma (HCC). Methods 30 cirrhotic patients underwent multiphasic MDCT in the 90 days before liver transplantation. MDCT was performed before contrast medium administration and during hepatic arterial hepatic venous and delayed phases, images were obtained at 12, 55 and 120 s after trigger threshold. Two radiologists qualitatively evaluated images for lesion attenuation. Tumour washout was evaluated subjectively and objectively. Tumour-to-liver contrast (TLC) was measured for all pathologically proven HCCs. Results 48 HCCs were detected at MDCT. 46 of the 48 tumours (96%) appeared as either hyper- or isoattenuating during the hepatic arterial phase subjective washout was present in 15 HCCs (33%) during the hepatic venous phase and in 35 (76%) during the delayed phase (p<0.001, McNemar’s test). Objective washout was present in 30 of the 46 HCCs (65%) during the hepatic venous phase and in 42 of the HCCs (91%) during the delayed phase (p=0.001). The delayed phase yielded significantly higher mean TLC absolute values compared with the hepatic venous phase (−16.1±10.8 HU vs −10.5±10.2 HU; p<0.001). Conclusions The delayed phase is superior to the hepatic venous phase for detection of tumour washout of pathologically proven HCC in cirrhotic patients. PMID:21081569
Miller, Julie M; Dewey, Marc; Vavere, Andrea L; Rochitte, Carlos E; Niinuma, Hiroyuki; Arbab-Zadeh, Armin; Paul, Narinder; Hoe, John; de Roos, Albert; Yoshioka, Kunihiro; Lemos, Pedro A; Bush, David E; Lardo, Albert C; Texter, John; Brinker, Jeffery; Cox, Christopher; Clouse, Melvin E; Lima, João A C
2009-04-01
Multislice computed tomography (MSCT) for the noninvasive detection of coronary artery stenoses is a promising candidate for widespread clinical application because of its non-invasive nature and high sensitivity and negative predictive value as found in several previous studies using 16 to 64 simultaneous detector rows. A multi-centre study of CT coronary angiography using 16 simultaneous detector rows has shown that 16-slice CT is limited by a high number of nondiagnostic cases and a high false-positive rate. A recent meta-analysis indicated a significant interaction between the size of the study sample and the diagnostic odds ratios suggestive of small study bias, highlighting the importance of evaluating MSCT using 64 simultaneous detector rows in a multi-centre approach with a larger sample size. In this manuscript we detail the objectives and methods of the prospective "CORE-64" trial ("Coronary Evaluation Using Multidetector Spiral Computed Tomography Angiography using 64 Detectors"). This multi-centre trial was unique in that it assessed the diagnostic performance of 64-slice CT coronary angiography in nine centres worldwide in comparison to conventional coronary angiography. In conclusion, the multi-centre, multi-institutional and multi-continental trial CORE-64 has great potential to ultimately assess the per-patient diagnostic performance of coronary CT angiography using 64 simultaneous detector rows.
Volvulus of the ascending colon in a non-rotated midgut: Plain film and MDCT findings.
Camera, Luigi; Calabrese, Milena; Mainenti, Pier Paolo; Masone, Stefania; Vecchio, Walter Del; Persico, Giovanni; Salvatore, Marco
2012-10-28
Colonic volvulus is a relatively uncommon cause of large bowel obstruction usually involving mobile, intra-peritoneal, colonic segments. Congenital or acquired anatomic variation may be associated with an increased risk of colonic volvulus which can occasionally involve retro-peritoneal segments. We report a case of 54-year-old female who presented to our Institution to perform a plain abdominal film series for acute onset of cramping abdominal pain. Both the upright and supine films showed signs of acute colonic obstruction which was thought to be due to an internal hernia of the transverse colon into the lesser sac. The patient was therefore submitted to a multi-detector contrast-enhanced computed tomography (CT). CT findings were initially thought to be consistent with the presumed diagnosis of internal hernia but further evaluation and coronal reformatting clearly depicted the presence of a colonic volvulus possibly resulting from a retro-gastric colon. At surgery, a volvulus of the ascending colon was found and a right hemi-colectomy had to be performed. However, a non rotated midgut with a right-sided duodeno-jejunal flexure and a left sided colon was also found at laparotomy and overlooked in the pre-operative CT. Retrospective evaluation of CT images was therefore performed and a number of CT signs of intestinal malrotation could be identified.
Computed Tomography of the Normal Bovine Tarsus.
Hagag, U; Tawfiek, M; Brehm, W; Gerlach, K
2016-12-01
The objective of this study was to provide a detailed multiplanar computed tomographic (CT) anatomic reference for the bovine tarsus. The tarsal regions from twelve healthy adult cow cadavers were scanned in both soft and bone windows via a 16-slice multidetector CT scanner. Tarsi were frozen at -20 o C and sectioned to 10-mm-thick slices in transverse, dorsal and sagittal planes respecting the imaging protocol. The frozen sections were cleaned and then photographed. Anatomic structures were identified, labelled and compared with the corresponding CT images. The sagittal plane was indispensable for evaluation of bone contours, the dorsal plane was valuable in examination of the collateral ligaments, and both were beneficial for assessment of the tarsal joint articulations. CT images allowed excellent delineation between the cortex and medulla of bones, and the trabecular structure was clearly depicted. The tarsal soft tissues showed variable shades of grey, and the synovial fluid was the lowest attenuated structure. This study provided full assessment of the clinically relevant anatomic structures of the bovine tarsal joint. This technique may be of value when results from other diagnostic imaging techniques are indecisive. Images presented in this study should serve as a basic CT reference and assist in the interpretation of various bovine tarsal pathology. © 2016 Blackwell Verlag GmbH.
Ye, Feng; Liu, Jun; Ouyang, Han
2015-08-01
The purpose of this meta-analysis was to compare the diagnostic accuracy of gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) and multidetector-row computed tomography (MDCT) for hepatocellular carcinoma (HCC).Medline, Cochrane, EMBASE, and Google Scholar databases were searched until July 4, 2014, using combinations of the following terms: gadoxetic acid disodium, Gd-EOB-DTPA, multidetector CT, contrast-enhanced computed tomography, and magnetic resonance imaging. Inclusion criteria were as follows: confirmed diagnosis of primary HCC by histopathological examination of a biopsy specimen; comparative study of MRI using Gd-EOB-DTPA and MDCT for diagnosis of HCC; and studies that provided quantitative outcome data. The pooled sensitivity and specificity of the 2 methods were compared, and diagnostic accuracy was assessed with alternative-free response receiver-operating characteristic analysis.Nine studies were included in the meta-analysis, and a total of 1439 lesions were examined. The pooled sensitivity and specificity for 1.5T MRI were 0.95 and 0.96, respectively, for 3.0T MRI were 0.91 and 0.96, respectively, and for MDCT were 0.74 and 0.93, respectively. The pooled diagnostic odds ratio for 1.5T and 3.0T MRI was 242.96, respectively, and that of MDCT was 33.47. To summarize, Gd-EOB-DTPA-enhanced MRI (1.5T and 3.0T) has better diagnostic accuracy for HCC than MDCT.
Maruyama, Shuki; Fukushima, Yasuhiro; Miyamae, Yuta; Koizumi, Koji
2018-06-01
This study aimed to investigate the effects of parameter presets of the forward projected model-based iterative reconstruction solution (FIRST) on the accuracy of pulmonary nodule volume measurement. A torso phantom with simulated nodules [diameter: 5, 8, 10, and 12 mm; computed tomography (CT) density: - 630 HU] was scanned with a multi-detector CT at tube currents of 10 mA (ultra-low-dose: UL-dose) and 270 mA (standard-dose: Std-dose). Images were reconstructed with filtered back projection [FBP; standard (Std-FBP), ultra-low-dose (UL-FBP)], FIRST Lung (UL-Lung), and FIRST Body (UL-Body), and analyzed with a semi-automatic software. The error in the volume measurement was determined. The errors with UL-Lung and UL-Body were smaller than that with UL-FBP. The smallest error was 5.8% ± 0.3 for the 12-mm nodule with UL-Body (middle lung). Our results indicated that FIRST Body would be superior to FIRST Lung in terms of accuracy of nodule measurement with UL-dose CT.
Oguma, Tsuyoshi; Hirai, Toyohiro; Niimi, Akio; Matsumoto, Hisako; Muro, Shigeo; Shigematsu, Michio; Nishimura, Takashi; Kubo, Yoshiro; Mishima, Michiaki
2013-01-01
Objectives (a) To assess the effects of computed tomography (CT) scanners, scanning conditions, airway size, and phantom composition on airway dimension measurement and (b) to investigate the limitations of accurate quantitative assessment of small airways using CT images. Methods An airway phantom, which was constructed using various types of material and with various tube sizes, was scanned using four CT scanner types under different conditions to calculate airway dimensions, luminal area (Ai), and the wall area percentage (WA%). To investigate the limitations of accurate airway dimension measurement, we then developed a second airway phantom with a thinner tube wall, and compared the clinical CT images of healthy subjects with the phantom images scanned using the same CT scanner. The study using clinical CT images was approved by the local ethics committee, and written informed consent was obtained from all subjects. Data were statistically analyzed using one-way ANOVA. Results Errors noted in airway dimension measurement were greater in the tube of small inner radius made of material with a high CT density and on images reconstructed by body algorithm (p<0.001), and there was some variation in error among CT scanners under different fields of view. Airway wall thickness had the maximum effect on the accuracy of measurements with all CT scanners under all scanning conditions, and the magnitude of errors for WA% and Ai varied depending on wall thickness when airways of <1.0-mm wall thickness were measured. Conclusions The parameters of airway dimensions measured were affected by airway size, reconstruction algorithm, composition of the airway phantom, and CT scanner types. In dimension measurement of small airways with wall thickness of <1.0 mm, the accuracy of measurement according to quantitative CT parameters can decrease as the walls become thinner. PMID:24116105
Bardo, Dianna M E; Brown, Paul
2008-08-01
Cardiac MDCT is here to stay. And, it is more than just imaging coronary arteries. Understanding the differences in and the benefits of one CT scanner from another will help you to optimize the capabilities of the scanner, but requires a basic understanding of the MDCT imaging physics.This review provides key information needed to understand the differences in the types of MDCT scanners, from 64 - 320 detectors, flat panels, single and dual source configurations, step and shoot prospective and retrospective gating, and how each factor influences radiation dose, spatial and temporal resolution, and image noise.
Aladmawi, Mohamed A; Pragliola, Claudio; Vriz, Olga; Galzerano, Domenico
2017-04-01
Obstruction of a mechanical aortic valve by pannus formation at the subvalvular level is a major long-term complication of aortic valve replacement (AVR). In fact, pannus is sometime difficult to differentiate from patient-prosthesis mismatch or valve thrombosis. In most cases cine-angiography and echocardiography, either transthoracic or transesophageal, cannot correctly visualize the complication when the leaflets show a normal mobility. Recent technological refinements made this difficult diagnosis possible by ECG-gated computed tomography (CT) scan which shows adequate images in 90% of the cases and can differentiate pannus from fresh and organized thrombus.
Subcutaneous Tissue Thickness is an Independent Predictor of Image Noise in Cardiac CT
Staniak, Henrique Lane; Sharovsky, Rodolfo; Pereira, Alexandre Costa; de Castro, Cláudio Campi; Benseñor, Isabela M.; Lotufo, Paulo A.; Bittencourt, Márcio Sommer
2014-01-01
Background Few data on the definition of simple robust parameters to predict image noise in cardiac computed tomography (CT) exist. Objectives To evaluate the value of a simple measure of subcutaneous tissue as a predictor of image noise in cardiac CT. Methods 86 patients underwent prospective ECG-gated coronary computed tomographic angiography (CTA) and coronary calcium scoring (CAC) with 120 kV and 150 mA. The image quality was objectively measured by the image noise in the aorta in the cardiac CTA, and low noise was defined as noise < 30HU. The chest anteroposterior diameter and lateral width, the image noise in the aorta and the skin-sternum (SS) thickness were measured as predictors of cardiac CTA noise. The association of the predictors and image noise was performed by using Pearson correlation. Results The mean radiation dose was 3.5 ± 1.5 mSv. The mean image noise in CT was 36.3 ± 8.5 HU, and the mean image noise in non-contrast scan was 17.7 ± 4.4 HU. All predictors were independently associated with cardiac CTA noise. The best predictors were SS thickness, with a correlation of 0.70 (p < 0.001), and noise in the non-contrast images, with a correlation of 0.73 (p < 0.001). When evaluating the ability to predict low image noise, the areas under the ROC curve for the non-contrast noise and for the SS thickness were 0.837 and 0.864, respectively. Conclusion Both SS thickness and CAC noise are simple accurate predictors of cardiac CTA image noise. Those parameters can be incorporated in standard CT protocols to adequately adjust radiation exposure. PMID:24173136
Busireddy, Kiran K; AlObaidy, Mamdoh; Ramalho, Miguel; Kalubowila, Janaka; Baodong, Liu; Santagostino, Ilaria; Semelka, Richard C
2014-01-01
Pancreatitis is defined as the inflammation of the pancreas and considered the most common pancreatic disease in children and adults. Imaging plays a significant role in the diagnosis, severity assessment, recognition of complications and guiding therapeutic interventions. In the setting of pancreatitis, wider availability and good image quality make multi-detector contrast-enhanced computed tomography (MD-CECT) the most used imaging technique. However, magnetic resonance imaging (MRI) offers diagnostic capabilities similar to those of CT, with additional intrinsic advantages including lack of ionizing radiation and exquisite soft tissue characterization. This article reviews the proposed definitions of revised Atlanta classification for acute pancreatitis, illustrates a wide range of morphologic pancreatic parenchymal and associated peripancreatic changes for different types of acute pancreatitis. It also describes the spectrum of early and late chronic pancreatitis imaging findings and illustrates some of the less common types of chronic pancreatitis, with special emphasis on the role of CT and MRI. PMID:25133027
Image quality improvement in MDCT cardiac imaging via SMART-RECON method
NASA Astrophysics Data System (ADS)
Li, Yinsheng; Cao, Ximiao; Xing, Zhanfeng; Sun, Xuguang; Hsieh, Jiang; Chen, Guang-Hong
2017-03-01
Coronary CT angiography (CCTA) is a challenging imaging task currently limited by the achievable temporal resolution of modern Multi-Detector CT (MDCT) scanners. In this paper, the recently proposed SMARTRECON method has been applied in MDCT-based CCTA imaging to improve the image quality without any prior knowledge of cardiac motion. After the prospective ECG-gated data acquisition from a short-scan angular span, the acquired data were sorted into several sub-sectors of view angles; each corresponds to a 1/4th of the short-scan angular range. Information of the cardiac motion was thus encoded into the data in each view angle sub-sector. The SMART-RECON algorithm was then applied to jointly reconstruct several image volumes, each of which is temporally consistent with the data acquired in the corresponding view angle sub-sector. Extensive numerical simulations were performed to validate the proposed technique and investigate the performance dependence.
Scialpi, Michele; Schiavone, Raffaele; D'Andrea, Alfredo; Palumbo, Isabella; Magli, Michelle; Gravante, Sabrina; Falcone, Giuseppe; De Filippi, Claudio; Manganaro, Lucia; Palumbo, Barbara
2015-05-01
To evaluate the image quality and the diagnostic efficacy by single-phase whole-body 64-slice multidetector CT (MDCT) for pediatric oncology. Chest-abdomen-pelvis CT examinations with single-phase split-bolus technique were evaluated for T: detection and delineation of primary tumor (assessment of the extent of the lesion to neighboring tissues), N: regional lymph nodes and M: distant metastasis. Quality scores (5-point scale) were assessed by two radiologists on parenchymal and vascular enhancement. Accurate TNM staging in term of detection and delineation of primary tumor, regional lymph nodes and distant metastasis was obtained in all cases. On the image quality and severity artifact, the Kappa value for the interobserver agreement measure obtained from the analysis was 0.754, (p<0.001), characterizing a very good agreement between observers. Single-pass total body CT split-bolus technique reached the highest overall image quality and an accurate TNM staging in pediatric patients with cancer. Copyright© 2015 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.
Diagnostic value of imaging in infective endocarditis: a systematic review.
Gomes, Anna; Glaudemans, Andor W J M; Touw, Daan J; van Melle, Joost P; Willems, Tineke P; Maass, Alexander H; Natour, Ehsan; Prakken, Niek H J; Borra, Ronald J H; van Geel, Peter Paul; Slart, Riemer H J A; van Assen, Sander; Sinha, Bhanu
2017-01-01
Sensitivity and specificity of the modified Duke criteria for native valve endocarditis are both suboptimal, at approximately 80%. Diagnostic accuracy for intracardiac prosthetic material-related infection is even lower. Non-invasive imaging modalities could potentially improve diagnosis of infective endocarditis; however, their diagnostic value is unclear. We did a systematic literature review to critically appraise the evidence for the diagnostic performance of these imaging modalities, according to PRISMA and GRADE criteria. We searched PubMed, Embase, and Cochrane databases. 31 studies were included that presented original data on the performance of electrocardiogram (ECG)-gated multidetector CT angiography (MDCTA), ECG-gated MRI, 18 F-fluorodeoxyglucose ( 18 F-FDG) PET/CT, and leucocyte scintigraphy in diagnosis of native valve endocarditis, intracardiac prosthetic material-related infection, and extracardiac foci in adults. We consistently found positive albeit weak evidence for the diagnostic benefit of 18 F-FDG PET/CT and MDCTA. We conclude that additional imaging techniques should be considered if infective endocarditis is suspected. We propose an evidence-based diagnostic work-up for infective endocarditis including these non-invasive techniques. Copyright © 2017 Elsevier Ltd. All rights reserved.
Luo, Mingxu; Song, Hongmei; Liu, Gang; Lin, Yikai; Luo, Lintao; Zhou, Xin; Chen, Bo
2017-01-01
The diagnostic values of diffusion weighted imaging (DWI) and 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) for N-staging of gastric cancer (GC) were identified and compared. After a systematic search to identify relevant articles, meta-analysis was used to summarize the sensitivities, specificities, and areas under curves (AUCs) for DWI and PET/CT. To better understand the diagnostic utility of DWI and PET/CT for N-staging, the performance of multi-detector computed tomography (MDCT) was used as a reference. Fifteen studies were analyzed. The pooled sensitivity, specificity, and AUC with 95% confidence intervals of DWI were 0.79 (0.73–0.85), 0.69 (0.61–0.77), and 0.81 (0.77–0.84), respectively. For PET/CT, the corresponding values were 0.52 (0.39–0.64), 0.88 (0.61–0.97), and 0.66 (0.62–0.70), respectively. Comparison of the two techniques revealed DWI had higher sensitivity and AUC, but no difference in specificity. DWI exhibited higher sensitivity but lower specificity than MDCT, and 18F-FDG PET/CT had lower sensitivity and equivalent specificity. Overall, DWI performed better than 18F-FDG PET/CT for preoperative N-staging in GC. When the efficacy of MDCT was taken as a reference, DWI represented a complementary imaging technique, while 18F-FDG PET/CT had limited utility for preoperative N-staging. PMID:29137440
Fan, L; Liu, S-Y; Li, Q-C; Yu, H; Xiao, X-S
2012-01-01
Objective To evaluate different features between benign and malignant pulmonary focal ground-glass opacity (fGGO) on multidetector CT (MDCT). Methods 82 pathologically or clinically confirmed fGGOs were retrospectively analysed with regard to demographic data, lesion size and location, attenuation value and MDCT features including shape, margin, interface, internal characteristics and adjacent structure. Differences between benign and malignant fGGOs were analysed using a χ2 test, Fisher's exact test or Mann–Whitney U-test. Morphological characteristics were analysed by binary logistic regression analysis to estimate the likelihood of malignancy. Results There were 21 benign and 61 malignant lesions. No statistical differences were found between benign and malignant fGGOs in terms of demographic data, size, location and attenuation value. The frequency of lobulation (p=0.000), spiculation (p=0.008), spine-like process (p=0.004), well-defined but coarse interface (p=0.000), bronchus cut-off (p=0.003), other air-containing space (p=0.000), pleural indentation (p=0.000) and vascular convergence (p=0.006) was significantly higher in malignant fGGOs than that in benign fGGOs. Binary logistic regression analysis showed that lobulation, interface and pleural indentation were important indicators for malignant diagnosis of fGGO, with the corresponding odds ratios of 8.122, 3.139 and 9.076, respectively. In addition, a well-defined but coarse interface was the most important indicator of malignancy among all interface types. With all three important indicators considered, the diagnostic sensitivity, specificity and accuracy were 93.4%, 66.7% and 86.6%, respectively. Conclusion An fGGO with lobulation, a well-defined but coarse interface and pleural indentation gives a greater than average likelihood of being malignant. PMID:22128130
Minamiguchi, Hiroki; Kawai, Nobuyuki; Sato, Morio; Ikoma, Akira; Sanda, Hiroki; Nakata, Kouhei; Tanaka, Fumihiro; Nakai, Motoki; Sonomura, Tetsuo; Murotani, Kazuhiro; Hosokawa, Seiki; Nishioku, Tadayoshi
2014-01-01
Aortography for detecting hemorrhage is limited when determining the catheter treatment strategy because the artery responsible for hemorrhage commonly overlaps organs and non-responsible arteries. Selective catheterization of untargeted arteries would result in repeated arteriography, large volumes of contrast medium, and extended time. A volume-rendered hemorrhage-responsible arteriogram created with 64 multidetector-row CT (64MDCT) during aortography (MDCTAo) can be used both for hemorrhage mapping and catheter navigation. The MDCTAo depicted hemorrhage in 61 of 71 cases of suspected acute arterial bleeding treated at our institute in the last 3 years. Complete hemostasis by embolization was achieved in all cases. The hemorrhage-responsible arteriogram was used for navigation during catheterization, thus assisting successful embolization. Hemorrhage was not visualized in the remaining 10 patients, of whom 6 had a pseudoaneurysm in a visceral artery; 1 with urinary bladder bleeding and 1 with chest wall hemorrhage had gaze tamponade; and 1 with urinary bladder hemorrhage and 1 with uterine hemorrhage had spastic arteries. Six patients with pseudoaneurysm underwent preventive embolization and the other 4 patients were managed by watchful observation. MDCTAo has the advantage of depicting the arteries responsible for hemoptysis, whether from the bronchial arteries or other systemic arteries, in a single scan. MDCTAo is particularly useful for identifying the source of acute arterial bleeding in the pancreatic arcade area, which is supplied by both the celiac and superior mesenteric arteries. In a case of pelvic hemorrhage, MDCTAo identified the responsible artery from among numerous overlapping visceral arteries that branched from the internal iliac arteries. In conclusion, a hemorrhage-responsible arteriogram created by 64MDCT immediately before catheterization is useful for deciding the catheter treatment strategy for acute arterial bleeding.
Woodhams, Reiko; Nishimaki, Hiroshi; Fujii, Kaoru; Kakita, Satoko; Hayakawa, Kazushige
2010-10-01
The purpose of this study was to assess the efficacy of multidetector-row CT (MDCT) for the diagnosis of non-occlusive mesenteric ischemia (NOMI) by analyzing morphology and diameter of superior mesenteric artery (SMA). We assessed whether MDCT was as useful as angiography for the diagnosis of NOMI. Four patients who were diagnosed with NOMI were retrospectively analyzed. All patients had 8-row MDCT followed by laparotomy. Two of them underwent angiography after MDCT. The morphology and diameter of SMA of these cases was analyzed on multi-planar reconstructed (MPR) images. The mean diameter of SMA of NOMI cases was compared to that of 13 control cases. MPR images of all NOMI cases showed irregular narrowing of the SMA, spasm of the arcades of SMA, and poor demonstration of intramural vessels. MPR images of two patients who had angiography were concordant with their angiograms. The mean diameter of SMA of NOMI patients was 3.4±1.1mm, which was statistically smaller than that of 13 control patients, 6.0±1.5mm (P<0.05, Wilcoxon rank sum tests). Angiography has been recognized essential for the diagnosis of NOMI. This study shows the possibility of MDCT to be an equivalently useful modality compared to angiography for the diagnosis of NOMI by interpreting morphologic appearance and diameter of SMA. Introduction of MDCT in the decision tree of NOMI treatment may bring the benefit of prompt diagnosis and subsequent early and efficient initiation of therapy, which may improve the mortality. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.
Mei, Kai; Kopp, Felix K; Bippus, Rolf; Köhler, Thomas; Schwaiger, Benedikt J; Gersing, Alexandra S; Fehringer, Andreas; Sauter, Andreas; Münzel, Daniela; Pfeiffer, Franz; Rummeny, Ernst J; Kirschke, Jan S; Noël, Peter B; Baum, Thomas
2017-12-01
Osteoporosis diagnosis using multidetector CT (MDCT) is limited to relatively high radiation exposure. We investigated the effect of simulated ultra-low-dose protocols on in-vivo bone mineral density (BMD) and quantitative trabecular bone assessment. Institutional review board approval was obtained. Twelve subjects with osteoporotic vertebral fractures and 12 age- and gender-matched controls undergoing routine thoracic and abdominal MDCT were included (average effective dose: 10 mSv). Ultra-low radiation examinations were achieved by simulating lower tube currents and sparse samplings at 50%, 25% and 10% of the original dose. BMD and trabecular bone parameters were extracted in T10-L5. Except for BMD measurements in sparse sampling data, absolute values of all parameters derived from ultra-low-dose data were significantly different from those derived from original dose images (p<0.05). BMD, apparent bone fraction and trabecular thickness were still consistently lower in subjects with than in those without fractures (p<0.05). In ultra-low-dose scans, BMD and microstructure parameters were able to differentiate subjects with and without vertebral fractures, suggesting osteoporosis diagnosis is feasible. However, absolute values differed from original values. BMD from sparse sampling appeared to be more robust. This dose-dependency of parameters should be considered for future clinical use. • BMD and quantitative bone parameters are assessable in ultra-low-dose in vivo MDCT scans. • Bone mineral density does not change significantly when sparse sampling is applied. • Quantitative trabecular bone microstructure measurements are sensitive to dose reduction. • Osteoporosis subjects could be differentiated even at 10% of original dose. • Radiation exposure should be considered when comparing quantitative bone parameters.
Jung, Seung Chai; Cho, Jeong Yeon
2011-01-01
Objective To determine the optimal iodine concentration of contrast media for kidney multidetector computed tomography (MDCT) by comparing the degree of renal parenchymal enhancement and the severity of the renal streak artifact with contrast media of different iodine concentrations. Materials and Methods A 16-row MDCT was performed in 15 sedated rabbits by injection of 2 mL contrast media/kg body weight at a rate of 0.3 mL/sec. Monomeric nonionic contrast media of 250, 300, and 370 mg iodine/mL were injected at 1-week intervals. Mean attenuation values were measured in each renal structure with attenuation differences among the structures. The artifact was evaluated by CT window width/level and three grading methods. The values were compared with iodine concentrations. Results The 370 mg iodine/mL concentration showed significantly higher cortical enhancement than 250 mg iodine/mL in all phases (p < 0.05). There was however no significant difference in the degree of enhancement between the 300 mg iodine/mL and 370 mg iodine/mL concentrations in all phases. There is a significant difference in attenuation for the cortex-outer medulla between 250 mg iodine/mL and 300 mg iodine/mL (p < 0.05). The artifact was more severe with a medium of 370 mg iodine/mL than with 250 mg iodine/mL by all grading methods (p < 0.05). Conclusion The 300 mg iodine/mL is considered to be the most appropriate iodine concentration in an aspect of the enhancement and artifact on a kidney MDCT scan. PMID:22043154
Ichikawa, Katsuhiro; Hara, Takanori; Urikura, Atsushi; Takata, Tadanori; Ohashi, Kazuya
2015-06-01
The purpose of this study was to propose a method for assessing the temporal resolution (TR) of multi-detector row computed tomography (CT) (MDCT) in the helical acquisition mode using temporal impulse signals generated by a metal ball passing through the acquisition plane. An 11-mm diameter metal ball was shot along the central axis at approximately 5 m/s during a helical acquisition, and the temporal sensitivity profile (TSP) was measured from the streak image intensities in the reconstructed helical CT images. To assess the validity, we compared the measured and theoretical TSPs for the 4-channel modes of two MDCT systems. A 64-channel MDCT system was used to compare TSPs and image quality of a motion phantom for the pitch factors P of 0.6, 0.8, 1.0 and 1.2 with a rotation time R of 0.5 s, and for two R/P combinations of 0.5/1.2 and 0.33/0.8. Moreover, the temporal transfer functions (TFs) were calculated from the obtained TSPs. The measured and theoretical TSPs showed perfect agreement. The TSP narrowed with an increase in the pitch factor. The image sharpness of the 0.33/0.8 combination was inferior to that of the 0.5/1.2 combination, despite their almost identical full width at tenth maximum values. The temporal TFs quantitatively confirmed these differences. The TSP results demonstrated that the TR in the helical acquisition mode significantly depended on the pitch factor as well as the rotation time, and the pitch factor and reconstruction algorithm affected the TSP shape. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Matsutani, Hideyuki; Sano, Tomonari; Kondo, Takeshi; Fujimoto, Shinichiro; Sekine, Takako; Arai, Takehiro; Morita, Hitomi; Takase, Shinichi
2010-12-20
A high radiation dose associated with 64 multidetector-row computed tomography (64-MDCT) is a major concern for physicians and patients alike. A new 320 row area detector computed tomography (ADCT) can obtain a view of the entire heart with one rotation (0.35 s) without requiring the helical method. As such, ADCT is expected to reduce the radiation dose. We studied image quality and radiation dose of ADCT compared to that of 64-MDCT in patients with a low heart rate (HR≤60). Three hundred eighty-five consecutive patients underwent 64-MDCT and 379 patients, ADCT. Patients with an arrhythmia were excluded. Prospective ECG-gated helical scan with high HP (FlashScan) in 64 was used for MDCT and prospective ECG-gated conventional one beat scan, for 320-ADCT. Image quality was visually evaluated by an image quality score. Radiation dose was estimated by DLP (mGy・cm) for 64-MDCT and DLP.e (mGy・cm) for 320-ADCT. Radiation dose of 320-ADCT (208±48 mGy・cm) was significantly (P<0.0001) lower than that of 64-MDCT (484±112 mGy・cm), and image quality score of 320-ADCT (3.0±0.2) was significantly (P=0.0011) higher than that of 64-MDCT (2.9±0.4). Scan time of 320-ADCT (1.4±0.1 s) was also significantly (P<0.0001) shorter than that of 64-MDCT (6.8±0.6 s). 320-ADCT can achieve not only a reduction in radiation dose but also a superior image quality and shortening of scan time compared to 64-MDCT.
Kim, Hyoung Woo; Lee, Jong-Chan; Paik, Kyu-Hyun; Kang, Jingu; Kim, Young Hoon; Yoon, Yoo-Seok; Han, Ho-Seong; Kim, Jaihwan; Hwang, Jin-Hyeok
2017-06-01
The adjunctive role of magnetic resonance imaging of the liver before pancreatic ductal adenocarcinoma has been unclear. We evaluated whether the combination of hepatic magnetic resonance imaging with multidetector computed tomography using a pancreatic protocol (pCT) could help surgeons select appropriate candidates and decrease the risk of early recurrence. We retrospectively enrolled 167 patients in whom complete resection was achieved without grossly visible residual tumor; 102 patients underwent pCT alone (CT group) and 65 underwent both hepatic magnetic resonance imaging and pCT (magnetic resonance imaging group). By adding hepatic magnetic resonance imaging during preoperative evaluation, hepatic metastases were newly discovered in 3 of 58 patients (5%) without hepatic lesions on pCT and 17 of 53 patients (32%) with indeterminate hepatic lesions on pCT. Patients with borderline resectability, a tumor size >3 cm, or preoperative carbohydrate antigen 19-9 level >1,000 U/mL had a greater rate of hepatic metastasis on subsequent hepatic magnetic resonance imaging. Among 167 patients in whom R0/R1 resection was achieved, the median overall survival was 18.2 vs 24.7 months (P = .020) and the disease-free survival was 8.5 vs 10.0 months (P = .016) in the CT and magnetic resonance imaging groups, respectively (median follow-up, 18.3 months). Recurrence developed in 82 (80%) and 43 (66%) patients in the CT and magnetic resonance imaging groups, respectively. The cumulative hepatic recurrence rate was greater in the CT group than in the magnetic resonance imaging group (P < .001). Preoperative hepatic magnetic resonance imaging should be considered in patients with potentially resectable pancreatic ductal adenocarcinoma, especially those with high tumor burden. Copyright © 2017 Elsevier Inc. All rights reserved.
Dynamic CT perfusion imaging of the myocardium: a technical note on improvement of image quality.
Muenzel, Daniela; Kabus, Sven; Gramer, Bettina; Leber, Vivian; Vembar, Mani; Schmitt, Holger; Wildgruber, Moritz; Fingerle, Alexander A; Rummeny, Ernst J; Huber, Armin; Noël, Peter B
2013-01-01
To improve image and diagnostic quality in dynamic CT myocardial perfusion imaging (MPI) by using motion compensation and a spatio-temporal filter. Dynamic CT MPI was performed using a 256-slice multidetector computed tomography scanner (MDCT). Data from two different patients-with and without myocardial perfusion defects-were evaluated to illustrate potential improvements for MPI (institutional review board approved). Three datasets for each patient were generated: (i) original data (ii) motion compensated data and (iii) motion compensated data with spatio-temporal filtering performed. In addition to the visual assessment of the tomographic slices, noise and contrast-to-noise-ratio (CNR) were measured for all data. Perfusion analysis was performed using time-density curves with regions-of-interest (ROI) placed in normal and hypoperfused myocardium. Precision in definition of normal and hypoperfused areas was determined in corresponding coloured perfusion maps. The use of motion compensation followed by spatio-temporal filtering resulted in better alignment of the cardiac volumes over time leading to a more consistent perfusion quantification and improved detection of the extend of perfusion defects. Additionally image noise was reduced by 78.5%, with CNR improvements by a factor of 4.7. The average effective radiation dose estimate was 7.1±1.1 mSv. The use of motion compensation and spatio-temporal smoothing will result in improved quantification of dynamic CT MPI using a latest generation CT scanner.
Patient-specific dose calculations for pediatric CT of the chest, abdomen and pelvis
Fraser, Nicholas D.; Carver, Diana E.; Pickens, David R.; Price, Ronald R.; Hernanz-Schulman, Marta; Stabin, Michael G.
2015-01-01
Background Organ dose is essential for accurate estimates of patient dose from CT. Objective To determine organ doses from a broad range of pediatric patients undergoing diagnostic chest–abdomen–pelvis CT and investigate how these relate to patient size. Materials and methods We used a previously validated Monte Carlo simulation model of a Philips Brilliance 64 multi-detector CT scanner (Philips Healthcare, Best, The Netherlands) to calculate organ doses for 40 pediatric patients (M:F=21:19; range 0.6–17 years). Organ volumes and positions were determined from the images using standard segmentation techniques. Non-linear regression was performed to determine the relationship between volume CT dose index (CTDIvol)-normalized organ doses and abdominopelvic diameter. We then compared results with values obtained from independent studies. Results We found that CTDIvol-normalized organ dose correlated strongly with exponentially decreasing abdominopelvic diameter (R2>0.8 for most organs). A similar relationship was determined for effective dose when normalized by dose-length product (R2=0.95). Our results agreed with previous studies within 12% using similar scan parameters (i.e. bowtie filter size, beam collimation); however results varied up to 25% when compared to studies using different bowtie filters. Conclusion Our study determined that organ doses can be estimated from measurements of patient size, namely body diameter, and CTDIvol prior to CT examination. This information provides an improved method for patient dose estimation. PMID:26142256
Sconfienza, Luca Maria; Mauri, Giovanni; Muzzupappa, Claudia; Poloni, Alessandro; Bandirali, Michele; Esseridou, Anastassia; Tritella, Stefania; Secchi, Francesco; Di Leo, Giovanni; Sardanelli, Francesco
2015-01-01
AIM: To investigate the prevalence of relevant incidental findings (RIFs) detected during routine abdominal contrast-enhanced computed tomography (CeCT). METHODS: We retrospectively evaluated the reports of a consecutive series of abdominal CeCT studies performed between January and May 2013. For each report, patients’ age and sex, admission as inpatient or outpatient, clinical suspicion as indicated by the requesting physician, availability of a previous abdominal examination, and name of the reporting radiologist were recorded. Based on the clinical suspicion, the presence and features of any RIFs (if needing additional workup) was noted. RESULTS: One thousand forty abdominal CeCT were performed in 949 patients (528 males, mean age 66 ± 14 years). No significant difference was found between inpatients and outpatients age and sex distribution (P > 0.472). RIFs were found in 195/1040 (18.8%) CeCT [inpatients = 108/470 (23.0%); outpatients = 87/570 (15.2%); P = 0.002]. RIFs were found in 30/440 (6.8%) CeCT with a previous exam and in 165/600 (27.5%) without a previous exam (P < 0.001). Radiologists’ distribution between inpatients or outpatients was significantly different (P < 0.001). RIFs prevalence increased with aging, except for a peak in 40-49 year group. Most involved organs were kidneys, gallbladder, and lungs. CONCLUSION: A RIF is detected in 1/5 patients undergoing abdominal CeCT. Risk of overdiagnosis should be taken into account. PMID:26516432
An iterative reconstruction method for high-pitch helical luggage CT
NASA Astrophysics Data System (ADS)
Xue, Hui; Zhang, Li; Chen, Zhiqiang; Jin, Xin
2012-10-01
X-ray luggage CT is widely used in airports and railway stations for the purpose of detecting contrabands and dangerous goods that may be potential threaten to public safety, playing an important role in homeland security. An X-ray luggage CT is usually in a helical trajectory with a high pitch for achieving a high passing speed of the luggage. The disadvantage of high pitch is that conventional filtered back-projection (FBP) requires a very large slice thickness, leading to bad axial resolution and helical artifacts. Especially when severe data inconsistencies are present in the z-direction, like the ends of a scanning object, the partial volume effect leads to inaccuracy value and may cause a wrong identification. In this paper, an iterative reconstruction method is developed to improve the image quality and accuracy for a large-spacing multi-detector high-pitch helical luggage CT system. In this method, the slice thickness is set to be much smaller than the pitch. Each slice involves projection data collected in a rather small angular range, being an ill-conditioned limited-angle problem. Firstly a low-resolution reconstruction is employed to obtain images, which are used as prior images in the following process. Then iterative reconstruction is performed to obtain high-resolution images. This method enables a high volume coverage speed and a thin reconstruction slice for the helical luggage CT. We validate this method with data collected in a commercial X-ray luggage CT.
Funama, Yoshinori; Awai, Kazuo; Hatemura, Masahiro; Shimamura, Masamitchi; Yanaga, Yumi; Oda, Seitaro; Yamashita, Yasuyuki
2008-01-01
To investigate whether it is possible to obtain adequate images at uniform image noise levels and reduced radiation exposure with our automatic tube current modulation (ATCM) technique for 64-detector CT. The study population consisted of 64 patients with known or suspected lung or abdominal disease. We used a 64-detector CT scanner (LightSpeed VCT, GE Healthcare, Waukesha, WI, USA) and a combined angular and longitudinal tube current modulation technique (Smart mA, GE Healthcare, Waukesha, WI, USA) to examine 34 patients. The scanning parameters were identical; the minimum and maximum tube current thresholds were 50 and 800 mA, respectively. For study of the constant tube current technique, 30 additional patients were examined at 350 mA. The CT number and image noise (SD of the CT number) were measured in the 64 patients at six levels, i.e., the center of the left ventricle, the liver dome, the porta hepatis, the center of the spleen and the right and left renal pelvis. When we used the ATCM technique, the mean image noise ranged from 8.40 at the center of the left ventricle to 11.31 at the porta hepatis; the mean tube current ranged from 105.9 mAs at the center of the left ventricle to 169.6 mAs at the center of the spleen. The mean dose reduction rate per constant tube current at 175 mAs ranged from 3.1 to 39.5%. By use of the ATCM technique, it is possible to maintain a constant image noise level with a 64-detector CT.
CT liver volumetry using geodesic active contour segmentation with a level-set algorithm
NASA Astrophysics Data System (ADS)
Suzuki, Kenji; Epstein, Mark L.; Kohlbrenner, Ryan; Obajuluwa, Ademola; Xu, Jianwu; Hori, Masatoshi; Baron, Richard
2010-03-01
Automatic liver segmentation on CT images is challenging because the liver often abuts other organs of a similar density. Our purpose was to develop an accurate automated liver segmentation scheme for measuring liver volumes. We developed an automated volumetry scheme for the liver in CT based on a 5 step schema. First, an anisotropic smoothing filter was applied to portal-venous phase CT images to remove noise while preserving the liver structure, followed by an edge enhancer to enhance the liver boundary. By using the boundary-enhanced image as a speed function, a fastmarching algorithm generated an initial surface that roughly estimated the liver shape. A geodesic-active-contour segmentation algorithm coupled with level-set contour-evolution refined the initial surface so as to more precisely fit the liver boundary. The liver volume was calculated based on the refined liver surface. Hepatic CT scans of eighteen prospective liver donors were obtained under a liver transplant protocol with a multi-detector CT system. Automated liver volumes obtained were compared with those manually traced by a radiologist, used as "gold standard." The mean liver volume obtained with our scheme was 1,520 cc, whereas the mean manual volume was 1,486 cc, with the mean absolute difference of 104 cc (7.0%). CT liver volumetrics based on an automated scheme agreed excellently with "goldstandard" manual volumetrics (intra-class correlation coefficient was 0.95) with no statistically significant difference (p(F<=f)=0.32), and required substantially less completion time. Our automated scheme provides an efficient and accurate way of measuring liver volumes.
The effects of misinterpretation of an artefact on multidetector row CT scans in children.
du Plessis, Anne-Marie; Theron, Salomine; Andronikou, Savvas
2009-02-01
Artefacts reflect problems with radiographic technique rather than true pathology. These may be misinterpreted as pathology with serious consequences. An artefact caused such problems in one paediatric imaging department. To determine the incidence, and consequences of misinterpretation, of a CT artefact in a paediatric imaging department. A retrospective review of images and reports of paediatric CT scans over a set period with a known artefact was performed. Reports were correlated with reviewers' evaluation of the presence of artefact and reviewed for correct identification of artefact, misinterpretation as pathology, and action taken as a result. A total of 74 CT scans had been performed over the study period and an artefact detected by reviewers on 32 (43%). Six (18.75%) of these were misinterpreted as pathology, of which three (9.4%) were reported as tuberculous granulomas, two (6.2%) as haemorrhages and one (3.1%) as an unknown hyperdensity. Two patients (6.2%) had subsequent MRI studies performed, and treatment for tuberculosis was continued in one patient (3.1%). No initial report identified the artefact. One-fifth of the scans with the artefact were misinterpreted as pathology and half of these misinterpretations led to further action. Artefacts result in false diagnoses and unnecessary investigations; vigilance is needed.
Budoff, Matthew J; Rader, Daniel J; Reilly, Muredach P.; Mohler, Emile R.; Lash, Jim; Yang, Wei; Rosen, Leigh; Glenn, Melanie; Teal, Valerie; Feldman, Harold I.
2011-01-01
Background Coronary artery calcification (CAC) is associated with increased mortality risk in the general population. Although individuals with chronic kidney disease (CKD) are at markedly increased mortality risk, the incidence, prevalence, and prognosis of CAC in CKD is not well-understood. Study Design Cross-sectional observational study. Setting and Participants Analysis of 1,908 participants who underwent coronary calcium scanning as part of the multi-ethnic CRIC (Chronic Renal Insufficiency Cohort) Study. Predictor Estimated glomerular filtration rate (eGFR) computed using the Modification of Diet in Renal Disease (MDRD) Study equation, stratified by race, sex and diabetic status. eGFR was treated as a continous variable and a categorical variable compared to the reference range of >60 ml/min/1.73 m2 Measurements CAC detected using CT scans using either an Imatron C-300 electron beam computed tomography scanner or multi-detector CT scanner. CAC was computed using the Agatston score, as a categorical variable. Analyses were performed using ordinal logistic regression. Results We found a strong and graded relationship between lower eGFR and increasing CAC. In unadjusted models, ORs increased from 1.68 (95% CI, 1.23–2.31) for eGFR from 50–59 to 2.82 (95% CI, 2.06–3.85) for eGFR of <30. Multivariable adjustment only partially attenuated the results (OR, 1.53; 95% CI, 1.07–2.20) for eGFR<30. Limitations Use of eGFR rather than measured GFR. Conclusions We demonstrated a graded relationship between severity of CKD and CAC, independent of traditional risk factors. These findings supports recent guidelines that state that if vascular calcification is present, it should be considered as a complementary component to be included in the decision making required for individualizing treatment of CKD. PMID:21783289
Xie, X; Willemink, M J; Zhao, Y; de Jong, P A; van Ooijen, P M A; Oudkerk, M; Greuter, M J W
2013-01-01
Objective: To assess inter- and intrascanner variability in volumetry of solid pulmonary nodules in an anthropomorphic thoracic phantom using low-dose CT. Methods: Five spherical solid artificial nodules [diameters 3, 5, 8, 10 and 12 mm; CT density +100 Hounsfield units (HU)] were randomly placed inside an anthropomorphic thoracic phantom in different combinations. The phantom was examined on two 64-row multidetector CT (64-MDCT) systems (CT-A and CT-B) from different vendors with a low-dose protocol. Each CT examination was performed three times. The CT examinations were evaluated twice by independent blinded observers. Nodule volume was semi-automatically measured by dedicated software. Interscanner variability was evaluated by Bland–Altman analysis and expressed as 95% confidence interval (CI) of relative differences. Intrascanner variability was expressed as 95% CI of relative variation from the mean. Results: No significant difference in CT-derived volume was found between CT-A and CT-B, except for the 3-mm nodules (p<0.05). The 95% CI of interscanner variability was within ±41.6%, ±18.2% and ±4.9% for 3, 5 and ≥8 mm nodules, respectively. The 95% CI of intrascanner variability was within ±28.6%, ±13.4% and ±2.6% for 3, 5 and ≥8 mm nodules, respectively. Conclusion: Different 64-MDCT scanners in low-dose settings yield good agreement in volumetry of artificial pulmonary nodules between 5 mm and 12 mm in diameter. Inter- and intrascanner variability decreases at a larger nodule size to a maximum of 4.9% for ≥8 mm nodules. Advances in knowledge: The commonly accepted cut-off of 25% to determine nodule growth has the potential to be reduced for ≥8 mm nodules. This offers the possibility of reducing the interval for repeated CT scans in lung cancer screenings. PMID:23884758
Yanagawa, Masahiro; Honda, Osamu; Kikuyama, Ayano; Gyobu, Tomoko; Sumikawa, Hiromitsu; Koyama, Mitsuhiro; Tomiyama, Noriyuki
2012-10-01
To evaluate the effects of ASIR on CAD system of pulmonary nodules using clinical routine-dose CT and lower-dose CT. Thirty-five patients (body mass index, 22.17 ± 4.37 kg/m(2)) were scanned by multidetector-row CT with tube currents (clinical routine-dose CT, automatically adjusted mA; lower-dose CT, 10 mA) and X-ray voltage (120 kVp). Each 0.625-mm-thick image was reconstructed at 0%-, 50%-, and 100%-ASIR: 0%-ASIR is reconstructed using only the filtered back-projection algorithm (FBP), while 100%-ASIR is reconstructed using the maximum ASIR and 50%-ASIR implies a blending of 50% FBP and ASIR. CAD output was compared retrospectively with the results of the reference standard which was established using a consensus panel of three radiologists. Data were analyzed using Bonferroni/Dunn's method. Radiation dose was calculated by multiplying dose-length product by conversion coefficient of 0.021. The consensus panel found 265 non-calcified nodules ≤ 30 mm (ground-glass opacity [GGO], 103; part-solid, 34; and solid, 128). CAD sensitivity was significantly higher at 100%-ASIR [clinical routine-dose CT, 71% (overall), 49% (GGO); lower-dose CT, 52% (overall), 67% (solid)] than at 0%-ASIR [clinical routine-dose CT, 54% (overall), 25% (GGO); lower-dose CT, 36% (overall), 50% (solid)] (p<0.001). Mean number of false-positive findings per examination was significantly higher at 100%-ASIR (clinical routine-dose CT, 8.5; lower-dose CT, 6.2) than at 0%-ASIR (clinical routine-dose CT, 4.6; lower-dose CT, 3.5; p<0.001). Effective doses were 10.77 ± 3.41 mSv in clinical routine-dose CT and 2.67 ± 0.17 mSv in lower-dose CT. CAD sensitivity at 100%-ASIR on lower-dose CT is almost equal to that at 0%-ASIR on clinical routine-dose CT. ASIR can increase CAD sensitivity despite increased false-positive findings. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Aladmawi, Mohamed A.; Vriz, Olga; Galzerano, Domenico
2017-01-01
Obstruction of a mechanical aortic valve by pannus formation at the subvalvular level is a major long-term complication of aortic valve replacement (AVR). In fact, pannus is sometime difficult to differentiate from patient-prosthesis mismatch or valve thrombosis. In most cases cine-angiography and echocardiography, either transthoracic or transesophageal, cannot correctly visualize the complication when the leaflets show a normal mobility. Recent technological refinements made this difficult diagnosis possible by ECG-gated computed tomography (CT) scan which shows adequate images in 90% of the cases and can differentiate pannus from fresh and organized thrombus. PMID:28540078
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, J; Chuong, M; Choi, W
Purpose: To identify PET/CT based imaging predictors of anal cancer recurrence and evaluate baseline vs. mid-treatment vs. post-treatment PET/CT scans in the tumor recurrence prediction. Methods: FDG-PET/CT scans were obtained at baseline, during chemoradiotherapy (CRT, midtreatment), and after CRT (post-treatment) in 17 patients of anal cancer. Four patients had tumor recurrence. For each patient, the mid-treatment and post-treatment scans were respectively aligned to the baseline scan by a rigid registration followed by a deformable registration. PET/CT image features were computed within the manually delineated tumor volume of each scan to characterize the intensity histogram, spatial patterns (texture), and shape ofmore » the tumors, as well as the changes of these features resulting from CRT. A total of 335 image features were extracted. An Exact Logistic Regression model was employed to analyze these PET/CT image features in order to identify potential predictors for tumor recurrence. Results: Eleven potential predictors of cancer recurrence were identified with p < 0.10, including five shape features, five statistical texture features, and one CT intensity histogram feature. Six features were indentified from posttreatment scans, 3 from mid-treatment scans, and 2 from baseline scans. These features indicated that there were differences in shape, intensity, and spatial pattern between tumors with and without recurrence. Recurrent tumors tended to have more compact shape (higher roundness and lower elongation) and larger intensity difference between baseline and follow-up scans, compared to non-recurrent tumors. Conclusion: PET/CT based anal cancer recurrence predictors were identified. The post-CRT PET/CT is the most important scan for the prediction of cancer recurrence. The baseline and mid-CRT PET/CT also showed value in the prediction and would be more useful for the predication of tumor recurrence in early stage of CRT. This work was supported in part by the National Cancer Institute Grant R01CA172638.« less
Jehle, Dietrich; Chae, Floria; Wai, Jonathan; Cloud, Sam; Pierce, David; Meyer, Michael
2012-01-01
CT angiography (CTA) has improved significantly over the past few years such that the reconstructed images of the cerebral arteries may now be equivalent to conventional digital angiography. The new technology of 64 slice multi-detector CTA can reconstruct detailed images that can reliably identify small cerebral aneurysms, even those <3mm. In addition, it is estimated that CT followed by lumbar puncture (LP) misses up to 4% of symptomatic aneurysms. We present a series of cases that illustrates how CT followed by CTA may be replacing CT-LP as the standard of care in working up patients for symptomatic cerebral aneurysms and the importance of performing three dimensional (3D) reconstructions. A series of seven cases of symptomatic cerebral aneurysms were identified that illustrate the sensitivity of CT-CTA versus CT-LP and the importance of 3D reconstruction in identifying these aneurysms. Surgical treatment was recommended for 6 of the 7 patients with aneurysms and strict hypertension control was recommended for the seventh patient. Some of these patients demonstrated subarachnoid hemorrhage on presentation while others had negative LPs. A number of these patients with negative LPs were clearly symptomatic from their aneurysms. At least one of these cerebral aneurysms was not apparent on CTA without 3D reconstruction. 3D reconstruction of CTA is crucial to adequately identify cerebral aneurysms. This case series helps reinforce the importance of 3D reconstruction. There is some data to suggest that 64 slice CT-CTA may be equivalent or superior to CT-LP in the detection of symptomatic cerebral aneurysms. PMID:22593806
Veladiano, Irene A; Banzato, Tommaso; Bellini, Luca; Montani, Alessandro; Catania, Salvatore; Zotti, Alessandro
2016-12-01
OBJECTIVE To create an atlas of the normal CT anatomy of the head of blue-and-gold macaws (Ara ararauna), African grey parrots (Psittacus erithacus), and monk parakeets (Myiopsitta monachus). ANIMALS 3 blue-and-gold macaws, 5 African grey parrots, and 6 monk parakeets and cadavers of 4 adult blue-and-gold macaws, 4 adult African grey parrots, and 7 monk parakeets. PROCEDURES Contrast-enhanced CT imaging of the head of the live birds was performed with a 4-multidetector-row CT scanner. Cadaveric specimens were stored at -20°C until completely frozen, and each head was then sliced at 5-mm intervals to create reference cross sections. Frozen cross sections were cleaned with water and photographed on both sides. Anatomic structures within each head were identified with the aid of the available literature, labeled first on anatomic photographs, and then matched to and labeled on corresponding CT images. The best CT reconstruction filter, window width, and window level for obtaining diagnostic images of each structure were also identified. RESULTS Most of the clinically relevant structures of the head were identified in both the cross-sectional photographs and corresponding CT images. Optimal visibility of the bony structures was achieved via CT with a standard soft tissue filter and pulmonary window. The use of contrast medium allowed a thorough evaluation of the soft tissues. CONCLUSIONS AND CLINICAL RELEVANCE The labeled CT images and photographs of anatomic structures of the heads of common pet parrot species created in this study may be useful as an atlas to aid interpretation of images obtained with any imaging modality.
Panda, Ananya; Kumar, Atin; Gamanagatti, Shivanand; Das, Ranjita; Paliwal, Swati; Gupta, Amit; Kumar, Subodh
2017-01-01
PURPOSE We aimed to assess the performance of computed tomography (CT) in localizing site of traumatic gastrointestinal tract (GIT) injury and determine the diagnostic value of CT signs in site localization. METHODS CT scans of 97 patients with surgically proven GIT or mesenteric injuries were retrospectively reviewed by radiologists blinded to surgical findings. Diagnosis of either GIT or mesenteric injuries was made. In patients with GIT injuries, site of injury and presence of CT signs such as focal bowel wall hyperenhancement, hypoenhancement, wall discontinuity, wall thickening, extramural air, intramural air, perivisceral infiltration, and active vascular contrast leak were evaluated. RESULTS Out of 97 patients, 90 had GIT injuries (70 single site injuries and 20 multiple site injuries) and seven had isolated mesenteric injury. The overall concordance between CT and operative findings for exact site localization was 67.8% (61/90), partial concordance rate was 11.1% (10/90), and discordance rate was 21.1% (19/90). For single site localization, concordance rate was 77.1% (54/70), discordance rate was 21.4% (15/70), and partial concordance rate was 1.4% (1/70). In multiple site injury, concordance rate for all sites of injury was 35% (7/20), partial concordance rate was 45% (9/20), and discordance rate was 20% (4/20). For upper GIT injuries, wall discontinuity was the most accurate sign for localization. For small bowel injury, intramural air and hyperenhancement were the most specific signs for site localization, while for large bowel injury, wall discontinuity and hypoenhancement were the most specific signs. CONCLUSION CT performs better in diagnosing small bowel injury compared with large bowel injury. CT can well predict the presence of multiple site injury but has limited performance in exact localization of all injury sites. PMID:27924777
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, H; Wang, J; Chuong, M
2015-06-15
Purpose: To evaluate the role of mid-treatment and post-treatment FDG-PET/CT in predicting progression-free survival (PFS) and distant metastasis (DM) of anal cancer patients treated with chemoradiotherapy (CRT). Methods: 17 anal cancer patients treated with CRT were retrospectively studied. The median prescription dose was 56 Gy (range, 50–62.5 Gy). All patients underwent FDG-PET/CT scans before and after CRT. 16 of the 17 patients had an additional FDG-PET/CT image at 3–5 weeks into the treatment (denoted as mid-treatment FDG-PET/CT). 750 features were extracted from these three sets of scans, which included both traditional PET/CT measures (SUVmax, SUVpeak, tumor diameters, etc.) and spatialtemporalmore » PET/CT features (comprehensively quantify a tumor’s FDG uptake intensity and distribution, spatial variation (texture), geometric property and their temporal changes relative to baseline). 26 clinical parameters (age, gender, TNM stage, histology, GTV dose, etc.) were also analyzed. Advanced analytics including methods to select an optimal set of predictors and a model selection engine, which identifies the most accurate machine learning algorithm for predictive analysis was developed. Results: Comparing baseline + mid-treatment PET/CT set to baseline + posttreatment PET/CT set, 14 predictors were selected from each feature group. Same three clinical parameters (tumor size, T stage and whether 5-FU was held during any cycle of chemotherapy) and two traditional measures (pre- CRT SUVmin and SUVmedian) were selected by both predictor groups. Different mix of spatial-temporal PET/CT features was selected. Using the 14 predictors and Naive Bayes, mid-treatment PET/CT set achieved 87.5% accuracy (2 PFS patients misclassified, all local recurrence and DM patients correctly classified). Post-treatment PET/CT set achieved 94.0% accuracy (all PFS and DM patients correctly predicted, 1 local recurrence patient misclassified) with logistic regression, neural network or support vector machine model. Conclusion: Applying radiomics approach to either midtreatment or post-treatment PET/CT could achieve high accuracy in predicting anal cancer treatment outcomes. This work was supported in part by the National Cancer Institute Grant R01CA172638.« less
Phillip, Veit; Zahel, Tina; Danninger, Assiye; Erkan, Mert; Dobritz, Martin; Steiner, Jörg M; Kleeff, Jörg; Schmid, Roland M; Algül, Hana
2015-01-01
Regeneration of the pancreas has been well characterized in animal models. However, there are conflicting data on the regenerative capacity of the human pancreas. The aim of the present study was to assess the regenerative capacity of the human pancreas. In a retrospective study, data from patients undergoing left partial pancreatic resection at a single center were eligible for inclusion (n = 185). Volumetry was performed based on 5 mm CT-scans acquired through a 256-slice CT-scanner using a semi-automated software. Data from 24 patients (15 males/9 females) were included. Mean ± SD age was 68 ± 11 years (range, 40-85 years). Median time between surgery and the 1st postoperative CT was 9 days (range, 0-27 days; IQR, 7-13), 55 days (range, 21-141 days; IQR, 34-105) until the 2nd CT, and 191 days (range, 62-1902; IQR, 156-347) until the 3rd CT. The pancreatic volumes differed significantly between the first and the second postoperative CT scans (median volume 25.6 mL and 30.6 mL, respectively; p = 0.008) and had significantly increased further by the 3rd CT scan (median volume 37.9 mL; p = 0.001 for comparison with 1st CT scan and p = 0.003 for comparison with 2nd CT scan). The human pancreas shows a measurable and considerable potential of volumetric gain after partial resection. Multidetector-CT based semi-automated volume analysis is a feasible method for follow-up of the volume of the remaining pancreatic parenchyma after partial pancreatectomy. Effects on exocrine and endocrine pancreatic function have to be evaluated in a prospective manner. Copyright © 2015 IAP and EPC. Published by Elsevier B.V. All rights reserved.
Soares, Bruno P; Tong, Elizabeth; Hom, Jason; Cheng, Su-Chun; Bredno, Joerg; Boussel, Loic; Smith, Wade S; Wintermark, Max
2010-01-01
The purpose of this study was to compare recanalization and reperfusion in terms of their predictive value for imaging outcomes (follow-up infarct volume, infarct growth, salvaged penumbra) and clinical outcome in acute ischemic stroke patients. Twenty-two patients admitted within 6 hours of stroke onset were retrospectively included in this study. These patients underwent a first stroke CT protocol including CT-angiography (CTA) and perfusion-CT (PCT) on admission, and similar imaging after treatment, typically around 24 hours, to assess recanalization and reperfusion. Recanalization was assessed by comparing arterial patency on admission and posttreatment CTAs; reperfusion, by comparing the volumes of CBV, CBF, and MTT abnormality on admission and posttreatment PCTs. Collateral flow was graded on the admission CTA. Follow-up infarct volume was measured on the discharge noncontrast CT. The groups of patients with reperfusion, no reperfusion, recanalization, and no recanalization were compared in terms of imaging and clinical outcomes. Reperfusion (using an MTT reperfusion index >75%) was a more accurate predictor of follow-up infarct volume than recanalization. Collateral flow and recanalization were not accurate predictors of follow-up infarct volume. An interaction term was found between reperfusion and the volume of the admission penumbra >50 mL. Our study provides evidence that reperfusion is a more accurate predictor of follow-up infarct volume in acute ischemic stroke patients than recanalization. We recommend an MTT reperfusion index >75% to assess therapy efficacy in future acute ischemic stroke trials that use perfusion-CT.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bostani, Maryam, E-mail: mbostani@mednet.ucla.edu; McMillan, Kyle; Lu, Peiyun
2015-02-15
Purpose: Task Group 204 introduced effective diameter (ED) as the patient size metric used to correlate size-specific-dose-estimates. However, this size metric fails to account for patient attenuation properties and has been suggested to be replaced by an attenuation-based size metric, water equivalent diameter (D{sub W}). The purpose of this study is to investigate different size metrics, effective diameter, and water equivalent diameter, in combination with regional descriptions of scanner output to establish the most appropriate size metric to be used as a predictor for organ dose in tube current modulated CT exams. Methods: 101 thoracic and 82 abdomen/pelvis scans frommore » clinically indicated CT exams were collected retrospectively from a multidetector row CT (Sensation 64, Siemens Healthcare) with Institutional Review Board approval to generate voxelized patient models. Fully irradiated organs (lung and breasts in thoracic scans and liver, kidneys, and spleen in abdominal scans) were segmented and used as tally regions in Monte Carlo simulations for reporting organ dose. Along with image data, raw projection data were collected to obtain tube current information for simulating tube current modulation scans using Monte Carlo methods. Additionally, previously described patient size metrics [ED, D{sub W}, and approximated water equivalent diameter (D{sub Wa})] were calculated for each patient and reported in three different ways: a single value averaged over the entire scan, a single value averaged over the region of interest, and a single value from a location in the middle of the scan volume. Organ doses were normalized by an appropriate mAs weighted CTDI{sub vol} to reflect regional variation of tube current. Linear regression analysis was used to evaluate the correlations between normalized organ doses and each size metric. Results: For the abdominal organs, the correlations between normalized organ dose and size metric were overall slightly higher for all three differently (global, regional, and middle slice) reported D{sub W} and D{sub Wa} than they were for ED, but the differences were not statistically significant. However, for lung dose, computed correlations using water equivalent diameter calculated in the middle of the image data (D{sub W,middle}) and averaged over the low attenuating region of lung (D{sub W,regional}) were statistically significantly higher than correlations of normalized lung dose with ED. Conclusions: To conclude, effective diameter and water equivalent diameter are very similar in abdominal regions; however, their difference becomes noticeable in lungs. Water equivalent diameter, specifically reported as a regional average and middle of scan volume, was shown to be better predictors of lung dose. Therefore, an attenuation-based size metric (water equivalent diameter) is recommended because it is more robust across different anatomic regions. Additionally, it was observed that the regional size metric reported as a single value averaged over a region of interest and the size metric calculated from a single slice/image chosen from the middle of the scan volume are highly correlated for these specific patient models and scan types.« less
Imaging in rectal cancer with emphasis on local staging with MRI
Arya, Supreeta; Das, Deepak; Engineer, Reena; Saklani, Avanish
2015-01-01
Imaging in rectal cancer has a vital role in staging disease, and in selecting and optimizing treatment planning. High-resolution MRI (HR-MRI) is the recommended method of first choice for local staging of rectal cancer for both primary staging and for restaging after preoperative chemoradiation (CT-RT). HR-MRI helps decide between upfront surgery and preoperative CT-RT. It provides high accuracy for prediction of circumferential resection margin at surgery, T category, and nodal status in that order. MRI also helps assess resectability after preoperative CT-RT and decide between sphincter saving or more radical surgery. Accurate technique is crucial for obtaining high-resolution images in the appropriate planes for correct staging. The phased array external coil has replaced the endorectal coil that is no longer recommended. Non-fat suppressed 2D T2-weighted (T2W) sequences in orthogonal planes to the tumor are sufficient for primary staging. Contrast-enhanced MRI is considered inappropriate for both primary staging and restaging. Diffusion-weighted sequence may be of value in restaging. Multidetector CT cannot replace MRI in local staging, but has an important role for evaluating distant metastases. Positron emission tomography-computed tomography (PET/CT) has a limited role in the initial staging of rectal cancer and is reserved for cases with resectable metastatic disease before contemplating surgery. This article briefly reviews the comprehensive role of imaging in rectal cancer, describes the role of MRI in local staging in detail, discusses the optimal MRI technique, and provides a synoptic report for both primary staging and restaging after CT-RT in routine practice. PMID:25969638
Perfusion CT to assess angiogenesis in colon cancer: technical limitations and practical challenges.
Dighe, S; Castellano, E; Blake, H; Jeyadevan, N; Koh, M U; Orten, M; Swift, I; Brown, G
2012-10-01
Perfusion CT may have the potential to quantify the degree of angiogenesis of solid tumours in vivo. This study aims to identify the practical and technical challenges inherent to the technique, and evaluate its feasibility in colorectal tumours. 51 patients from 2 institutions prospectively underwent a single perfusion CT on 2 different multidetector scanners. The patients were advised to breath-hold as long as possible, followed by shallow breathing, and were given intravenous buscopan to reduce movement. Numerous steps were explored to identify the challenges. 43 patients successfully completed the perfusion CT as per protocol. Inability to detect the tumour (n=3), misplacement of dynamic sequence co-ordinates (n=2), failure of contrast injection (n=2) and displacement of tumour (n=1) were the reasons for failure. In 14 cases excessive respiratory motion displaced the tumour out of the scanning field along the temporal sequence, leading to erroneous data capture. In nine patients, minor displacements of the tumour were corrected by repositioning the region of interest (ROI) to its original position after reviewing each dynamic sequence slice. In 20 patients the tumour was stable, and data captured from the ROI were representative, and could have been analysed by commercially available Body Tumor Perfusion 3.0® software (GE Healthcare, Waukesha, WI). Hence all data were manually analysed by MATLAB® processing software (MathWorks, Cambridge, UK). Perfusion CT in tumours susceptible to motion during acquisition makes accurate data capture challenging and requires meticulous attention to detail. Motion correction software is essential if perfusion CT is to be used routinely in colorectal cancer.
Contrast Enhancement of the Right Ventricle during Coronary CT Angiography--Is It Necessary?
Kok, Madeleine; Kietselaer, Bas L J H; Mihl, Casper; Altintas, Sibel; Nijssen, Estelle C; Wildberger, Joachim E; Das, Marco
2015-01-01
It is unclear if prolonged contrast media injection, to improve right ventricular visualization during coronary CT angiography, leads to increased detection of right ventricle pathology. The purpose of this study was to evaluate right ventricle enhancement and subsequent detection of right ventricle disease during coronary CT angiography. 472 consecutive patients referred for screening coronary CT angiography were retrospectively evaluated. Every patient underwent multidetector-row CT of the coronary arteries: 128x 0.6mm coll., 100-120kV, rot. time 0.28s, ref. mAs 350 and received an individualized (P3T) contrast bolus injection of iodinated contrast medium (300 mgI/ml). Patient data were analyzed to assess right ventricle enhancement (HU) and right ventricle pathology. Image quality was defined good when right ventricle enhancement >200HU, moderate when 140-200HU and poor when <140HU. Good image quality was found in 372 patients, moderate in 80 patients and poor in 20 patients. Mean enhancement of the right ventricle cavity was 268HU±102. Patients received an average bolus of 108±24 ml at an average peak flow rate of 6.1±2.2 ml/s. In only three out of 472 patients (0.63%) pathology of the right ventricle was found (dilatation) No other right ventricle pathology was detected. Right ventricle pathology was detected in three out of 472 patients; the dilatation observed in these three cases may have been picked up even without dedicated enhancement of the right ventricle. Based on our findings, right ventricle enhancement can be omitted during screening coronary CT angiography.
Kim, Jin Woo; Choo, Ki Seok; Jeon, Ung Bae; Kim, Tae Un; Hwang, Jae Yeon; Yeom, Jeong A; Jeong, Hee Seok; Choi, Yoon Young; Nam, Kyung Jin; Kim, Chang Won; Jeong, Dong Wook; Lim, Soo Jin
2016-07-01
Multi-detector computed tomography (MDCT) angiography is now used for the diagnosing patients with peripheral arterial disease. The dose of radiation is related to variable factors, such as tube current, tube voltage, and helical pitch. To assess the diagnostic performance and radiation dose of lower extremity CT angiography (CTA) using a 128-slice dual source CT at 80 kVp and high pitch in patients with critical limb ischemia (CLI). Twenty-eight patients (mean, 64.1 years; range, 39-80 years) with CLI were enrolled in this retrospective study and underwent CTA using a 128-slice dual source CT at 80 kVp and high pitch and subsequent intra-arterial digital subtraction angiography (DSA), which was used as a reference standard for assessing diagnostic performance. For arterial segments with significant disease (>50% stenosis), overall sensitivity, specificity, and accuracy of lower extremity CTA were 94.8% (95% CI, 91.7-98.0%), 91.5% (95% CI, 87.7-95.2%), and 93.1% (95% CI, 90.6-95.6%), respectively, and its positive and negative predictive values were 91.0% (95% CI, 87.1-95.0%), and 95.1% (95% CI, 92.1-98.1%), respectively. Mean radiation dose delivered to lower extremities was 266.6 mGy.cm. Lower extremity CTA using a 128-slice dual source CT at 80 kVp and high pitch was found to have good diagnostic performance for the assessment of patients with CLI using an extremely low radiation dose. © The Foundation Acta Radiologica 2015.
Multi-detector CT features of acute intestinal ischemia and their prognostic correlations.
Moschetta, Marco; Telegrafo, Michele; Rella, Leonarda; Stabile Ianora, Amato Antonio; Angelelli, Giuseppe
2014-05-28
Acute intestinal ischemia is an abdominal emergency occurring in nearly 1% of patients presenting with acute abdomen. The causes can be occlusive or non occlusive. Early diagnosis is important to improve survival rates. In most cases of late or missed diagnosis, the mortality rate from intestinal infarction is very high, with a reported value ranging from 60% to 90%. Multi-detector computed tomography (MDCT) is a fundamental imaging technique that must be promptly performed in all patients with suspected bowel ischemia. Thanks to the new dedicated reconstruction program, its diagnostic potential is much improved compared to the past and currently it is superior to that of any other noninvasive technique. The increased spatial and temporal resolution, high-quality multi-planar reconstructions, maximum intensity projections, vessel probe, surface-shaded volume rending and tissue transition projections make MDCT the gold standard for the diagnosis of intestinal ischemia, with reported sensitivity, specificity, positive and negative predictive values of 64%-93%, 92%-100%, 90%-100% and 94%-98%, respectively. MDCT contributes to appropriate treatment planning and provides important prognostic information thanks to its ability to define the nature and extent of the disease. The purpose of this review is to examine the diagnostic and prognostic role of MDCT in bowel ischemia with special regard to the state of art new reconstruction software.
Zhu, Caisong; Liu, Wei; Yang, Jun; Yang, Jing; Shao, Kangwei; Yuan, Lixin; Chen, Hairong; Lu, Wei; Zhu, Ying
2016-07-01
The aim of the present study was to compare the multidetector computed tomography (MDCT) features of benign and malignant nodules in patients with chronic lymphocytic thyroiditis (CLT). MDCT findings, including the size, solid percentage, calcification, margin, capsule, anteroposterior-transverse diameter ratio as well as the mode and the degree of enhancement of 137 thyroid nodules in 127 CLT cases were retrospectively analyzed. Furthermore, the correlation between MDCT findings and pathological results combined with the CT perfusion imaging was analyzed for the differences between benign and malignant nodules. A total of 77.5% (31/40) of malignant nodules were completely solid, and 33% (32/97) of benign nodules were predominantly cystic. Compared with the benign nodules, micro-calcification and internal calcification were more frequently observed in the malignant nodules (P<0.05). MDCT features such as ill-defined margin, absence of capsule or incomplete capsule or homogeneous enhancement were more likely to be present in the malignant nodules (P<0.05). Nevertheless, no significant difference was observed in the enhancement degree at arterial or venous phase between benign and malignant nodules (P>0.05). MDCT features are useful in differentiating the benign and malignant nodules in CLT patients, and it may be essential for a radiologist to review the MDCT characteristics of nodules in the clinical practice.
Wang, Qiushi; Juan, Yu-Hsiang; Li, Yong; Xie, Jia-Jun; Liu, Hui; Huang, Hongfei; Liu, Zaiyi; Zheng, Junhui; Saboo, Ujwala S.; Saboo, Sachin S.; Liang, Changhong
2015-01-01
Abstract This study aims to evaluate the multidetector computed tomography (CT) imaging features in differentiating exophytic renal angiomyolipoma (AML) from retroperitoneal liposarcoma. We retrospectively enrolled 42 patients with confirmed exophytic renal AML (31 patients) or retroperitoneal liposarcoma (11 patients) during 8 years period to assess: renal parenchymal defect at site of tumor contact, supply from branches of renal artery, tumoral vessel extending through the renal parenchyma, dilated intratumoral vessels, hemorrhage, non–fat-containing intratumoral nodules with postcontrast enhancement, calcification, renal sinus enlargement, anterior displacement of kidneys, and other associated AML. Renal parenchymal defect, renal arterial blood supply, tumoral vessel through the renal parenchyma, dilated intratumoral vessels, intratumoral/perirenal hemorrhage, renal sinus enlargement, and associated AML were seen only or mainly in exophytic renal AML (all P value < 0.05); however, non–fat-attenuating enhancing intratumoral nodules, intratumoral calcification, and anterior displacement of the kidney were more common in liposarcoma (all P value < 0.05). AMLs reveal renal parenchymal defect at the site of tumor contact, supply from renal artery, tumoral vessel extending through the renal parenchyma, dilated intratumoral vessels, intratumoral and/or perirenal hemorrhage, renal sinus enlargement, and associated AML. Non–fat-attenuating enhancing intratumoral nodules, intratumoral calcifications, and anterior displacement of kidney were more commonly seen in liposarcoma. PMID:26376398
Kulkarni, S; Emre, S; Arvelakis, A; Asch, W; Bia, M; Formica, R; Israel, G
2011-01-01
Multidetector computed tomography (MDCT) angiography is a reliable technique for assessing pre-operative renal anatomy in living kidney donors. The method has largely evolved into protocols that eliminate dedicated venous phase and instead utilize a combined arterial/venous phase to delineate arterial and venous anatomy simultaneously. Despite adoption of this protocol, there has been no study to assess its accuracy. To assess whether or not MDCT angiography compares favorably to intra-operative findings, 102 donors underwent MDCT angiography without a dedicated venous phase with surgical interpretation of renal anatomy. Anatomical variants included multiple arteries (12%), multiple veins (7%), early arterial bifurcation (13%), late venous confluence (5%), circumaortic renal veins (5%), retroaortic vein (1%), and ureteral duplication (2%). The sensitivity and specificity of multiple arterial anomalies were 100% and 97%, respectively. The sensitivity and specificity of multiple venous anomalies were 92% and 98%, respectively. The most common discrepancy was noted exclusively in the interpretation of right venous anatomy as it pertained to the renal vein/vena cava confluence (3%). MDCT angiography using a combined arterial/venous contrast-enhanced phase provides suitable depiction of renal donor anatomy. Careful consideration should be given when planning a right donor nephrectomy whether the radiographic interpretation is suggestive of a late confluence. © 2010 John Wiley & Sons A/S.
Goh, Vicky; Halligan, Steve; Hugill, Jo-Ann; Gartner, Louise; Bartram, Clive I
2005-01-01
To determine the effect of acquisition time on quantitative colorectal cancer perfusion measurement. Dynamic contrast-enhanced computed tomography (CT) was performed prospectively in 10 patients with histologically proven colorectal cancer using 4-detector row CT (Lightspeed Plus; GE Healthcare Technologies, Waukesha, WI). Tumor blood flow, blood volume, mean transit time, and permeability were assessed for 3 acquisition times (45, 65, and 130 seconds). Mean values for all 4 perfusion parameters for each acquisition time were compared using the paired t test. Significant differences in permeability values were noted between acquisitions of 45 seconds and 65 and 130 seconds, respectively (P=0.02, P=0.007). There was no significant difference for values of blood volume, blood flow, and mean transit time between any of the acquisition times. Scan acquisitions of 45 seconds are too short for reliable permeability measurement in the abdomen. Longer acquisition times are required.
The Abernethy malformation-myriad imaging manifestations of a single entity.
Ghuman, Samarjit S; Gupta, Saumya; Buxi, T B S; Rawat, Kishan S; Yadav, Anurag; Mehta, Naimish; Sud, Seema
2016-01-01
Abernethy malformation, also known as congenital extrahepatic portosystemic shunts (CEPS) is a rare clinical entity and manifests with different clinical symptoms. CEPS are abnormalities of vascular development where there is shunting of portal blood into the systemic venous system. Multidetector computed tomography (MDCT) is a fast and effective modality for evaluation of CEPS. CT displays all the information desired by the surgeon as well as the clinician including the anatomy of the splenic and superior mesenteric veins, size and site of the shunt, presence or absence of the portal vein radicles, and helps to plan the therapy and even the follow-up of these patients. Contrast-enhanced magnetic resonance imaging (MRI) has also emerged as a promising tool for the evaluation of liver lesions associated with the malformation. The Radiologist should be aware of the various imaging appearances of this entity including its complications. In this article, we describe the imaging appearances of CEPS, their complications, and their imaging appearances on CT and MRI. We have also described various associated anomalies.
Ekizoglu, Oguzhan; Inci, Ercan; Hocaoglu, Elif; Sayin, Ibrahim; Kayhan, Fatma Tulin; Can, Ismail Ozgur
2014-05-01
Gender determination is an important step in identification. For gender determination, anthropometric evaluation is one of the main forensic evaluations. In the present study, morphometric analysis of maxillary sinuses was performed to determine gender. For morphometric analysis, coronal and axial paranasal sinus computed tomography (CT) scan with 1-mm slice thickness was used. For this study, 140 subjects (70 women and 70 men) were enrolled (age ranged between 18 and 63). The size of each subject's maxillary sinuses was measured in anteroposterior, transverse, cephalocaudal, and volume directions. In each measurement, the size of the maxillary sinus is significantly small in female gender (P < 0.001). When discrimination analysis was performed, the accuracy rate was detected as 80% for women and 74.3% for men with an overall rate of 77.15%. With the use of 1-mm slice thickness CT, morphometric analysis of maxillary sinuses will be helpful for gender determination.
The Abernethy malformation—myriad imaging manifestations of a single entity
Ghuman, Samarjit S; Gupta, Saumya; Buxi, T B S; Rawat, Kishan S; Yadav, Anurag; Mehta, Naimish; Sud, Seema
2016-01-01
Abernethy malformation, also known as congenital extrahepatic portosystemic shunts (CEPS) is a rare clinical entity and manifests with different clinical symptoms. CEPS are abnormalities of vascular development where there is shunting of portal blood into the systemic venous system. Multidetector computed tomography (MDCT) is a fast and effective modality for evaluation of CEPS. CT displays all the information desired by the surgeon as well as the clinician including the anatomy of the splenic and superior mesenteric veins, size and site of the shunt, presence or absence of the portal vein radicles, and helps to plan the therapy and even the follow-up of these patients. Contrast-enhanced magnetic resonance imaging (MRI) has also emerged as a promising tool for the evaluation of liver lesions associated with the malformation. The Radiologist should be aware of the various imaging appearances of this entity including its complications. In this article, we describe the imaging appearances of CEPS, their complications, and their imaging appearances on CT and MRI. We have also described various associated anomalies. PMID:27857464
Matsumoto, Masatoshi; Koike, Soichi; Kashima, Saori; Awai, Kazuo
2015-01-01
Japan has the most CT and MRI scanners per unit population in the world; however, the geographic distribution of these technologies is currently unknown. Moreover, nothing is known of the cause-effect relationship between the number of diagnostic imaging devices and their geographic distribution. Data on the number of CT, MRI and PET devices and that of their utilizations in all 1829 municipalities of Japan was generated, based on the Static Survey of Medical Institutions conducted by the government. The inter-municipality equity of the number of devices or utilizations was evaluated with Gini coefficient. Between 2005 and 2011, the number of CT, MRI and PET devices in Japan increased by 47% (8789 to 12945), 19% (5034 to 5990) and 70% (274 to 466), respectively. Gini coefficient of the number of devices was largest for PET and smallest for CT (p for PET-MRI difference <0.001; MRI-CT difference <0.001). For all three modalities, Gini coefficient steadily decreased (p for 2011-2005 difference: <0.001 for CT; 0.003 for MRI; and <0.001 for PET). The number of devices in old models (single-detector CT, MRI<1.5 tesla, and conventional PET) decreased, while that in new models (multi-detector CT, MRI≥1.5 tesla, and PET-CT) increased. Gini coefficient of the old models increased or remained unchanged (increase rate of 9%, 3%, and -1%; p for 2011-2008 difference <0.001, 0.072, and 0.562, respectively), while Gini coefficient of the new models decreased (-10%, -9%, and -10%; p for 2011-2008 difference <0.001, <0.001, and <0.001 respectively). Similar results were observed in terms of utilizations. The more abundant a modality, the more equal the modality's distribution. Any increase in the modality made its distribution more equal. The geographic distribution of the diagnostic imaging technology in Japan appears to be affected by spatial competition derived from a market force.
Neri, E; Laghi, A; Regge, D; Sacco, P; Gallo, T; Turini, F; Talini, E; Ferrari, R; Mellaro, M; Rengo, M; Marchi, S; Caramella, D; Bartolozzi, C
2008-12-01
The aim of this paper is to describe the Web site of the Italian Project on CT Colonography (Research Project of High National Interest, PRIN No. 2005062137) and present the prototype of the online database. The Web site was created with Microsoft Office Publisher 2003 software, which allows the realisation of multiple Web pages linked through a main menu located on the home page. The Web site contains a database of computed tomography (CT) colonography studies in the Digital Imaging and Communications in Medicine (DICOM) standard, all acquired with multidetector-row CT according to the parameters defined by the European Society of Abdominal and Gastrointestinal Radiology (ESGAR). The cases present different bowel-cleansing and tagging methods, and each case has been anonymised and classified according to the Colonography Reporting and Data System (C-RADS). The Web site is available at http address www.ctcolonography.org and is composed of eight pages. Download times for a 294-Mbyte file were 33 min from a residential ADSL (6 Mbit/s) network, 200 s from a local university network (100 Mbit/s) and 2 h and 50 min from a remote academic site in the USA. The Web site received 256 accesses in the 22 days since it went online. The Web site is an immediate and up-to-date tool for publicising the activity of the research project and a valuable learning resource for CT colonography.
NASA Astrophysics Data System (ADS)
Fahmi, Rachid; Eck, Brendan L.; Vembar, Mani; Bezerra, Hiram G.; Wilson, David L.
2014-03-01
Dynamic cardiac CT perfusion (CTP) is a high resolution, non-invasive technique for assessing myocardial blood ow (MBF), which in concert with coronary CT angiography enable CT to provide a unique, comprehensive, fast analysis of both coronary anatomy and functional ow. We assessed perfusion in a porcine model with and without coronary occlusion. To induce occlusion, each animal underwent left anterior descending (LAD) stent implantation and angioplasty balloon insertion. Normal ow condition was obtained with balloon completely de ated. Partial occlusion was induced by balloon in ation against the stent with FFR used to assess the extent of occlusion. Prospective ECG-triggered partial scan images were acquired at end systole (45% R-R) using a multi-detector CT (MDCT) scanner. Images were reconstructed using FBP and a hybrid iterative reconstruction (iDose4, Philips Healthcare). Processing included: beam hardening (BH) correction, registration of image volumes using 3D cubic B-spline normalized mutual-information, and spatio-temporal bilateral ltering to reduce partial scan artifacts and noise variation. Absolute blood ow was calculated with a deconvolutionbased approach using singular value decomposition (SVD). Arterial input function was estimated from the left ventricle (LV) cavity. Regions of interest (ROIs) were identi ed in healthy and ischemic myocardium and compared in normal and occluded conditions. Under-perfusion was detected in the correct LAD territory and ow reduction agreed well with FFR measurements. Flow was reduced, on average, in LAD territories by 54%.
A new cubic phantom for PET/CT dosimetry: Experimental and Monte Carlo characterization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Belinato, Walmir; Silva, Rogerio M.V.; Souza, Divanizia N.
In recent years, positron emission tomography (PET) associated with multidetector computed tomography (MDCT) has become a diagnostic technique widely disseminated to evaluate various malignant tumors and other diseases. However, during PET/CT examinations, the doses of ionizing radiation experienced by the internal organs of patients may be substantial. To study the doses involved in PET/CT procedures, a new cubic phantom of overlapping acrylic plates was developed and characterized. This phantom has a deposit for the placement of the fluorine-18 fluoro-2-deoxy-D-glucose ({sup 18}F-FDG) solution. There are also small holes near the faces for the insertion of optically stimulated luminescence dosimeters (OSLD). Themore » holes for OSLD are positioned at different distances from the {sup 18}F-FDG deposit. The experimental results were obtained in two PET/CT devices operating with different parameters. Differences in the absorbed doses were observed in OSLD measurements due to the non-orthogonal positioning of the detectors inside the phantom. This phantom was also evaluated using Monte Carlo simulations, with the MCNPX code. The phantom and the geometrical characteristics of the equipment were carefully modeled in the MCNPX code, in order to develop a new methodology form comparison of experimental and simulated results, as well as to allow the characterization of PET/CT equipments in Monte Carlo simulations. All results showed good agreement, proving that this new phantom may be applied for these experiments. (authors)« less
Efficacy of CT in diagnosis of transudates and exudates in patients with pleural effusion
Çullu, Neşat; Kalemci, Serdar; Karakaş, Ömer; Eser, İrfan; Yalçın, Funda; Boyacı, Fatıma Nurefşan; Karakaş, Ekrem
2014-01-01
PURPOSE We aimed to evaluate the efficacy of multidetector computed tomography (CT) imaging in diagnosis of pleural exudates and transudates using attenuation values. MATERIALS AND METHODS This retrospective study included 106 patients who were diagnosed with pleural effusion between January 2010 and June 2012. After the patients underwent chest CT, thoracentesis was performed in the first week. The attenuation values of the pleural effusions were measured in all patients. RESULTS According to Light’s criteria, 30 of 106 patients with pleural effusions had transudates, and the remaining patients had exudates. The Hounsfield unit (HU) value of the exudates (median, 12.5; range, 4–33) was significantly higher than that of the transudates (median, 5; range, 2–15) (P = 0.001). Additionally, when evaluated by disease subgroups, congestive heart failure and empyema were predictable in terms of median HU values of the pleural effusions with high and moderate sensitivity and specificity values (84.6% and 81.2%, respectively; 76.9% and 66.7%, respectively). Compared with other patients, the empyema patients had significantly more loculation and pleural thickening. CONCLUSION CT attenuation values may be useful in differentiating exu-dates from transudates. Although there is an overlap in most effusions, exudate can be considered when the CT attenuation values are >15 HU. Because of overlapping HU values, close correlation with clinical findings is essential. Additional signs, such as fluid loculation and pleural thickness, should be considered and may provide further information for the differentiation. PMID:24100060
Efficacy of CT in diagnosis of transudates and exudates in patients with pleural effusion.
Çullu, Neşat; Kalemci, Serdar; Karakaş, Ömer; Eser, İrfan; Yalçin, Funda; Boyacı, Fatıma Nurefşan; Karakaş, Ekrem
2014-01-01
We aimed to evaluate the efficacy of multidetector computed tomography (CT) imaging in diagnosis of pleural exudates and transudates using attenuation values. This retrospective study included 106 patients who were diagnosed with pleural effusion between January 2010 and June 2012. After the patients underwent chest CT, thoracentesis was performed in the first week. The attenuation values of the pleural effusions were measured in all patients. According to Light's criteria, 30 of 106 patients with pleural effusions had transudates, and the remaining patients had exudates. The Hounsfield unit (HU) value of the exudates (median, 12.5; range, 4-33) was significantly higher than that of the transudates (median, 5; range, 2-15) (P = 0.001). Additionally, when evaluated by disease subgroups, congestive heart failure and empyema were predictable in terms of median HU values of the pleural effusions with high and moderate sensitivity and specificity values (84.6% and 81.2%, respectively; 76.9% and 66.7%, respectively). Compared with other patients, the empyema patients had significantly more loculation and pleural thickening. CT attenuation values may be useful in differentiating exudates from transudates. Although there is an overlap in most effusions, exudate can be considered when the CT attenuation values are >15 HU. Because of overlapping HU values, close correlation with clinical findings is essential. Additional signs, such as fluid loculation and pleural thickness, should be considered and may provide further information for the differentiation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suckling, Tara; Smith, Tony; Reed, Warren
2013-06-15
Optimal arterial opacification is crucial in imaging the pulmonary arteries using computed tomography (CT). This poses the challenge of precisely timing data acquisition to coincide with the transit of the contrast bolus through the pulmonary vasculature. The aim of this quality assurance exercise was to investigate if a change in CT pulmonary angiography (CTPA) scanning protocol resulted in improved opacification of the pulmonary arteries. Comparison was made between the smart prep protocol (SPP) and the test bolus protocol (TBP) for opacification in the pulmonary trunk. A total of 160 CTPA examinations (80 using each protocol) performed between January 2010 andmore » February 2011 were assessed retrospectively. CT attenuation coefficients were measured in Hounsfield Units (HU) using regions of interest at the level of the pulmonary trunk. The average pixel value, standard deviation (SD), maximum, and minimum were recorded. For each of these variables a mean value was then calculated and compared for these two CTPA protocols. Minimum opacification of 200 HU was achieved in 98% of the TBP sample but only 90% of the SPP sample. The average CT attenuation over the pulmonary trunk for the SPP was 329 (SD = ±21) HU, whereas for the TBP it was 396 (SD = ±22) HU (P = 0.0017). The TBP also recorded higher maximum (P = 0.0024) and minimum (P = 0.0039) levels of opacification. This study has found that a TBP resulted in significantly better opacification of the pulmonary trunk than the SPP.« less
US characteristics for the prediction of neoplasm in gallbladder polyps 10 mm or larger.
Kim, Jin Sil; Lee, Jeong Kyong; Kim, Yookyung; Lee, Sang Min
2016-04-01
To evaluate the characteristics of gallbladder polyps 10 mm or larger to predict a neoplasm in US examinations. Fifty-three patients with gallbladder polyps ≥ 10 mm with follow-up images or pathologic diagnosis were included in the retrospective study. All images and reports were reviewed to determine the imaging characteristics of gallbladder polyps. Univariate and multivariate analyses were used to evaluate predictors for a neoplastic polyp. A neoplastic polyp was verified in 12 of 53 patients and the mean size was 13.9 mm. The univariate analysis revealed that adjacent gallbladder wall thickening, larger size (≥15 mm), older age (≥57 years), absence of hyperechoic foci in a polyp, CT visibility, sessile shape, a solitary polyp, and an irregular surface were significant predictors for a neoplastic polyp. In the multivariate analysis, larger size (≥15 mm) was a significant predictor for a neoplastic polyp. A polyp size ≥15 mm was the strongest predictor for a neoplastic polyp with US. The hyperechoic foci in a polyp and CT visibility would be useful indicators for the differentiation of a neoplastic polyp, in addition to the established predictors. • A polyp size ≥15 mm is the strongest predictor for a neoplastic polyp with US. • Hyperechoic foci in a polyp and CT visibility are new predictors. • The rate of malignancy is low in polyps even 10 mm or larger (15.1 %).
Application of multidetector-row computed tomography in propeller flap planning.
Ono, Shimpei; Chung, Kevin C; Hayashi, Hiromitsu; Ogawa, Rei; Takami, Yoshihiro; Hyakusoku, Hiko
2011-02-01
The propeller flap is defined as (1) being island-shaped, (2) having an axis that includes the perforators, and (3) having the ability to be rotated around an axis. The advantage of the propeller flap is that it is a pedicle flap that can be applied to cover defects located at the distal ends of the extremities. The specific aims of the authors' study were (1) to evaluate the usefulness of multidetector-row computed tomography in the planning of propeller flaps and (2) to present a clinical case series of propeller flap reconstructions that were planned preoperatively using multidetector-row computed tomography. The authors retrospectively analyzed all cases between April of 2007 and April of 2010 at Nippon Medical School Hospital in Tokyo, where multidetector-row computed tomography was used preoperatively to plan surgical reconstructions using propeller flaps. Thirteen patients underwent 16 flaps using the propeller flap technique. The perforators were identified accurately by multidetector-row computed tomography preoperatively in all cases. This is the first report describing the application of multidetector-row computed tomography in the planning of propeller flaps. Multidetector-row computed tomography is superior to other imaging methods because it demonstrates more precisely the perforator's position and subcutaneous course using high-resolution three-dimensional images. By using multidetector-row computed tomography to preoperatively identify a flap's perforators, the surgeon can better plan the flap design to efficiently conduct the flap surgery.
Multi-national findings on radiation protection of children.
Rehani, Madan M
2014-10-01
This article reviews issues of radiation protection in children in 52 low-resource countries. Extensive information was obtained through a survey by the International Atomic Energy Agency (IAEA); wide-ranging information was available from 40 countries and data from the other countries pertained to frequency of pediatric CT examinations. Of note is that multi-detector CT (MDCT) was available in 77% of responses to the survey, typically nodal centers in these countries. Nearly 75% of these scanners were reported to have dose displays. The pediatric CT usage was lower in European facilities as compared to Asian and African facilities, where usage was twice as high. The most frequently scanned body part was the head. Frequent use of 120 kVp was reported in children. The ratio of maximum to minimum CT dose index volume (CTDIvol) values varied between 15 for abdomen CT in the age group 5-10 years and 100 for chest CT in the age group <1 year. In 8% of the CT systems, CTDI values for pediatric patients were higher than those for adults in at least one age group and for one type of examination. Use of adult protocols for children was associated with CTDIw or CTDIvol values in children that were double those of adults for head and chest examination and 50% higher for abdomen examination. Patient dose records were kept in nearly half of the facilities, with the highest frequency in Europe (55% of participating facilities), and in 49% of Asian, 36% of Latin American and 14% of African facilities. The analysis of the first-choice examinations in seven clinical conditions showed that practice was in accordance with guidelines for only three of seven specified clinical conditions.
McCollough, Cynthia H; Ulzheimer, Stefan; Halliburton, Sandra S; Shanneik, Kaiss; White, Richard D; Kalender, Willi A
2007-05-01
To develop a consensus standard for quantification of coronary artery calcium (CAC). A standard for CAC quantification was developed by a multi-institutional, multimanufacturer international consortium of cardiac radiologists, medical physicists, and industry representatives. This report specifically describes the standardization of scan acquisition and reconstruction parameters, the use of patient size-specific tube current values to achieve a prescribed image noise, and the use of the calcium mass score to eliminate scanner- and patient size-based variations. An anthropomorphic phantom containing calibration inserts and additional phantom rings were used to simulate small, medium-size, and large patients. The three phantoms were scanned by using the recommended protocols for various computed tomography (CT) systems to determine the calibration factors that relate measured CT numbers to calcium hydroxyapatite density and to determine the tube current values that yield comparable noise values. Calculation of the calcium mass score was standardized, and the variance in Agatston, volume, and mass scores was compared among CT systems. Use of the recommended scanning parameters resulted in similar noise for small, medium-size, and large phantoms with all multi-detector row CT scanners. Volume scores had greater interscanner variance than did Agatston and calcium mass scores. Use of a fixed calcium hydroxyapatite density threshold (100 mg/cm(3)), as compared with use of a fixed CT number threshold (130 HU), reduced interscanner variability in Agatston and calcium mass scores. With use of a density segmentation threshold, the calcium mass score had the smallest variance as a function of patient size. Standardized quantification of CAC yielded comparable image noise, spatial resolution, and mass scores among different patient sizes and different CT systems and facilitated reduced radiation dose for small and medium-size patients.
Conklin, Laren R; Strunk, Daniel R; Cooper, Andrew A
2018-02-01
Homework assignments are an integral part of cognitive therapy (CT) for depression, though facilitating homework engagement in patients with depression can be a challenge. We sought to examine three classes of therapist behaviors as predictors of homework engagement in early sessions of CT: therapist behaviors related to the review of homework, the assignment of homework, and efforts to help patients overcome obstacles to completing homework. In a sample of 66 depressed outpatients participating in CT, therapist behaviors involved in assigning homework predicted both CT-specific homework engagement and more general homework engagement. Therapist behaviors involved in homework review were not predictive of homework engagement. Our findings are consistent with the possibility that therapists' emphasis of key elements of the homework assignment process enhances patients' engagement in homework in early sessions of CT.
Critical thinking skills of undergraduate nursing students: description and demographic predictors.
Hunter, Sharyn; Pitt, Victoria; Croce, Nic; Roche, Jan
2014-05-01
This study investigated the critical thinking skills among undergraduate nursing students in Australia to obtain a profile and determine demographic predictors of critical thinking. There is universal agreement that being a critical thinker is an outcome requirement for many accreditation and registering nursing bodies. Most studies provide descriptive statistical information about critical thinking skills while some have studied the changes in critical thinking after an intervention. Limited research about factors that predict critical thinking skills is available. A cross-sectional descriptive study was conducted using convenience sampling. Two hundred and sixty-nine students were recruited across three years of an undergraduate programme in 2009. Most students' age ranged from under 20 to 34 years (58%), 87% were female, 91% were Australian and 23% of first and second year students had nursing associated experience external to the university. Data about critical thinking skills were collected via the Health Science Reasoning Test (HSRT). Linear regression analysis investigated the predictors of nursing students' critical thinking skills. The students in third year had a profile of critical thinking skills comparable with HSRT norms. Year of study predicted higher critical thinking scores for all domains (p<0.001) except the subscale, analysis. Nationality predicted higher scores for total CT skill scores (p<0.001) and subscales, inductive (p=0.001) and deductive reasoning (p=0.001). Nursing associated experience predicted higher scores for the subscale, analysis (p<0.001). Age and gender were not predictive. However, these demographic predictors only accounted for a small variance obtained for the domains of CT skills. An understanding of factors that predict nursing students' CT skills is required. Despite this study finding a number of significant predictors of nursing students' CT skills, there are others yet to be understood. Future research is recommended exploring explicit CT instructional approaches and nursing students' CT skills. © 2013 Elsevier Ltd. All rights reserved.
Assessment of chest CT at CTDIvol less than 1 mGy with iterative reconstruction techniques.
Padole, Atul; Digumarthy, Subba; Flores, Efren; Madan, Rachna; Mishra, Shelly; Sharma, Amita; Kalra, Mannudeep K
2017-03-01
To assess the image quality of chest CT reconstructed with image-based iterative reconstruction (SafeCT; MedicVision ® , Tirat Carmel, Israel), adaptive statistical iterative reconstruction (ASIR; GE Healthcare, Waukesha, WI) and model-based iterative reconstruction (MBIR; GE Healthcare, Waukesha, WI) techniques at CT dose index volume (CTDI vol ) <1 mGy. In an institutional review board-approved study, 25 patients gave written informed consent for acquisition of three reduced dose (0.25-, 0.4- and 0.8-mGy) chest CT after standard of care CT (8 mGy) on a 64-channel multidetector CT (MDCT) and reconstructed with SafeCT, ASIR and MBIR. Two board-certified thoracic radiologists evaluated images from the lowest to the highest dose of the reduced dose CT series and subsequently for standard of care CT. Out of the 182 detected lesions, the missed lesions were 35 at 0.25, 24 at 0.4 and 9 at 0.8 mGy with SafeCT, ASIR and MBIR, respectively. The most missed lesions were non-calcified lung nodules (NCLNs) 25/112 (<5 mm) at 0.25, 18/112 (<5 mm) at 0.4 and 3/112 (<4 mm) at 0.8 mGy. There were 78%, 84% and 97% lung nodules detected at 0.25, 0.4 and 0.8 mGy, respectively regardless of iterative reconstruction techniques (IRTs), Most mediastinum structures were not sufficiently seen at 0.25-0.8 mGy. NCLNs can be missed in chest CT at CTDI vol of <1 mGy (0.25, 0.4 and 0.8 mGy) regardless of IRTs. The most lung nodules (97%) were detected at CTDI vol of 0.8 mGy. The most mediastinum structures were not sufficiently seen at 0.25-0.8 mGy. Advances in knowledge: NCLNs can be missed regardless of IRTs in chest CT at CTDI vol of <1 mGy. The performance of ASIR, SafeCT and MBIR was similar for lung nodule detection at 0.25, 0.4 and 0.8 mGy.
Measuring coronary calcium on CT images adjusted for attenuation differences.
Nelson, Jennifer Clark; Kronmal, Richard A; Carr, J Jeffrey; McNitt-Gray, Michael F; Wong, Nathan D; Loria, Catherine M; Goldin, Jonathan G; Williams, O Dale; Detrano, Robert
2005-05-01
To quantify scanner and participant variability in attenuation values for computed tomographic (CT) images assessed for coronary calcium and define a method for standardizing attenuation values and calibrating calcium measurements. Institutional review board approval and participant informed consent were obtained at all study sites. An image attenuation adjustment method involving the use of available calibration phantom data to define standard attenuation values was developed. The method was applied to images from two population-based multicenter studies: the Coronary Artery Risk Development in Young Adults study (3041 participants) and the Multi-Ethnic Study of Atherosclerosis (6814 participants). To quantify the variability in attenuation, analysis of variance techniques were used to compare the CT numbers of standardized torso phantom regions across study sites, and multivariate linear regression models of participant-specific calibration phantom attenuation values that included participant age, race, sex, body mass index (BMI), smoking status, and site as covariates were developed. To assess the effect of the calibration method on calcium measurements, Pearson correlation coefficients between unadjusted and attenuation-adjusted calcium measurements were computed. Multivariate models were used to examine the effect of sex, race, BMI, smoking status, unadjusted score, and site on Agatston score adjustments. Mean attenuation values (CT numbers) of a standard calibration phantom scanned beneath participants varied significantly according to scanner and participant BMI (P < .001 for both). Values were lowest for Siemens multi-detector row CT scanners (110.0 HU), followed by GE-Imatron electron-beam (116.0 HU) and GE LightSpeed multi-detector row scanners (121.5 HU). Values were also lower for morbidly obese (BMI, > or =40.0 kg/m(2)) participants (108.9 HU), followed by obese (BMI, 30.0-39.9 kg/m(2)) (114.8 HU), overweight (BMI, 25.0-29.9 kg/m(2)) (118.5 HU), and normal-weight or underweight (BMI, <25.0 kg/m(2)) (120.1 HU) participants. Agatston score calibration adjustments ranged from -650 to 1071 (mean, -8 +/- 50 [standard deviation]) and increased with Agatston score (P < .001). The direction and magnitude of adjustment varied significantly according to scanner and BMI (P < .001 for both) and were consistent with phantom attenuation results in that calibration resulted in score decreases for images with higher phantom attenuation values. Image attenuation values vary by scanner and participant body size, producing calcium score differences that are not due to true calcium burden disparities. Use of calibration phantoms to adjust attenuation values and calibrate calcium measurements in research studies and clinical practice may improve the comparability of such measurements between persons scanned with different scanners and within persons over time.
Li, Qi; Zhang, Gang; Huang, Yuan-Jun; Dong, Mei-Xue; Lv, Fa-Jin; Wei, Xiao; Chen, Jian-Jun; Zhang, Li-Juan; Qin, Xin-Yue; Xie, Peng
2015-08-01
Early hematoma growth is not uncommon in patients with intracerebral hemorrhage and is an independent predictor of poor functional outcome. The purpose of our study was to report and validate the use of our newly identified computed tomographic (CT) blend sign in predicting early hematoma growth. Patients with intracerebral hemorrhage who underwent baseline CT scan within 6 hours after onset of symptoms were included. The follow-up CT scan was performed within 24 hours after the baseline CT scan. Significant hematoma growth was defined as an increase in hematoma volume of >33% or an absolute increase of hematoma volume of >12.5 mL. The blend sign on admission nonenhanced CT was defined as blending of hypoattenuating area and hyperattenuating region with a well-defined margin. Univariate and multivariable logistic regression analyses were performed to assess the relationship between the presence of the blend sign on nonenhanced admission CT and early hematoma growth. A total of 172 patients were included in our study. Blend sign was observed in 29 of 172 (16.9%) patients with intracerebral hemorrhage on baseline nonenhanced CT scan. Of the 61 patients with hematoma growth, 24 (39.3%) had blend sign on admission CT scan. Interobserver agreement for identifying blend sign was excellent between the 2 readers (κ=0.957). The multivariate logistic regression analysis demonstrated that the time to baseline CT scan, initial hematoma volume, and presence of blend sign on baseline CT scan to be independent predictors of early hematoma growth. The sensitivity, specificity, positive and negative predictive values of blend sign for predicting hematoma growth were 39.3%, 95.5%, 82.7%, and 74.1%, respectively. The CT blend sign could be easily identified on regular nonenhanced CT and is highly specific for predicting hematoma growth. © 2015 American Heart Association, Inc.
NASA Astrophysics Data System (ADS)
Boehm, H. F.; Fink, C.; Becker, C.; Reiser, M.
2007-03-01
Reliable and accurate methods for objective quantitative assessment of parenchymal alterations in the lung are necessary for diagnosis, treatment and follow-up of pulmonary diseases. Two major types of alterations are pulmonary emphysema and fibrosis, emphysema being characterized by abnormal enlargement of the air spaces distal to the terminal, nonrespiratory bronchiole, accompanied by destructive changes of the alveolar walls. The main characteristic of fibrosis is coursening of the interstitial fibers and compaction of the pulmonary tissue. With the ability to display anatomy free from superimposing structures and greater visual clarity, Multi-Detector-CT has shown to be more sensitive than the chest radiograph in identifying alterations of lung parenchyma. In automated evaluation of pulmonary CT-scans, quantitative image processing techniques are applied for objective evaluation of the data. A number of methods have been proposed in the past, most of which utilize simple densitometric tissue features based on the mean X-ray attenuation coefficients expressed in terms of Hounsfield Units [HU]. Due to partial volume effects, most of the density-based methodologies tend to fail, namely in cases, where emphysema and fibrosis occur within narrow spatial limits. In this study, we propose a methodology based upon the topological assessment of graylevel distribution in the 3D image data of lung tissue which provides a way of improving quantitative CT evaluation. Results are compared to the more established density-based methods.
Faure, Marguerite E; Swart, Laurens E; Dijkshoorn, Marcel L; Bekkers, Jos A; van Straten, Marcel; Nieman, Koen; Parizel, Paul M; Krestin, Gabriel P; Budde, Ricardo P J
2018-05-01
Multidetector CT (MDCT) is a valuable tool for functional prosthetic heart valve (PHV) assessment. However, radiation exposure remains a concern. We assessed a novel CT-acquisition protocol for comprehensive PHV evaluation at limited dose. Patients with a PHV were scanned using a third-generation dual-source CT scanner (DSCT) and iterative reconstruction technique (IR). Three acquisitions were obtained: a non-enhanced scan; a contrast-enhanced, ECG-triggered, arterial CT angiography (CTA) scan with reconstructions at each 5 % of the R-R interval; and a delayed high-pitch CTA of the entire chest. Image quality was scored on a five-point scale. Radiation dose was obtained from the reported CT dose index (CTDI) and dose length product (DLP). We analysed 43 CT examinations. Mean image quality score was 4.1±1.4, 4.7±0.5 and 4.2±0.6 for the non-contrast-enhanced, arterial and delayed acquisitions, respectively, with a total mean image quality of 4.3±0.7. Mean image quality for leaflet motion was 3.9±1.4. Mean DLP was 28.2±17.1, 457.3±168.6 and 68.5±47.2 mGy.cm for the non-contrast-enhanced (n=40), arterial (n=43) and delayed acquisition (n=43), respectively. The mean total DLP was 569±208 mGy.cm and mean total radiation dose was 8.3±3.0 mSv (n=43). Comprehensive assessment of PHVs is possible using DSCT and IR at moderate radiation dose. • Prosthetic heart valve dysfunction is a potentially life-threatening condition. • Dual-source CT can adequately assess valve leaflet motion and anatomy. • We assessed a comprehensive protocol with three acquisitions for PHV evaluation. • This protocol is associated with good image quality and limited dose.
Fayed, Nirmeen; Mourad, Wessam; Yassen, Khaled; Görlinger, Klaus
2015-03-01
The ability to predict transfusion requirements may improve perioperative bleeding management as an integral part of a patient blood management program. Therefore, the aim of our study was to evaluate preoperative thromboelastometry as a predictor of transfusion requirements for adult living donor liver transplant recipients. The correlation between preoperative thromboelastometry variables in 100 adult living donor liver transplant recipients and intraoperative blood transfusion requirements was examined by univariate and multivariate linear regression analysis. Thresholds of thromboelastometric parameters for prediction of packed red blood cells (PRBCs), fresh frozen plasma (FFP), platelets, and cryoprecipitate transfusion requirements were determined with receiver operating characteristics analysis. The attending anesthetists were blinded to the preoperative thromboelastometric analysis. However, a thromboelastometry-guided transfusion algorithm with predefined trigger values was used intraoperatively. The transfusion triggers in this algorithm did not change during the study period. Univariate analysis confirmed significant correlations between PRBCs, FFP, platelets or cryoprecipitate transfusion requirements and most thromboelastometric variables. Backward stepwise logistic regression indicated that EXTEM coagulation time (CT), maximum clot firmness (MCF) and INTEM CT, clot formation time (CFT) and MCF are independent predictors for PRBC transfusion. EXTEM CT, CFT and FIBTEM MCF are independent predictors for FFP transfusion. Only EXTEM and INTEM MCF were independent predictors of platelet transfusion. EXTEM CFT and MCF, INTEM CT, CFT and MCF as well as FIBTEM MCF are independent predictors for cryoprecipitate transfusion. Thromboelastometry-based regression equation accounted for 63% of PRBC, 83% of FFP, 61% of cryoprecipitate, and 44% of platelet transfusion requirements. Preoperative thromboelastometric analysis is helpful to predict transfusion requirements in adult living donor liver transplant recipients. This may allow for better preparation and less cross-matching prior to surgery. The findings of our study need to be re-validated in a second prospective patient population.
Differentiation of benign and malignant ampullary obstruction by multi-row detector CT.
Angthong, Wirana; Jiarakoop, Kran; Tangtiang, Kaan
2018-05-21
To determine useful CT parameters to differentiate ampullary carcinomas from benign ampullary obstruction. This study included 93 patients who underwent abdominal CT, 31 patients with ampullary carcinomas, and 62 patients with benign ampullary obstruction. Two radiologists independently evaluated CT parameters then reached consensus decisions. Statistically significant CT parameters were identified through univariate and multivariate analyses. In univariate analysis, the presence of ampullary mass, asymmetric, abrupt narrowing of distal common bile duct (CBD), dilated intrahepatic bile duct (IHD), dilated pancreatic duct (PD), peripancreatic lymphadenopathy, duodenal wall thickening, and delayed enhancement were more frequently in ampullary carcinomas observed (P < 0.05). Multivariate logistic regression analysis using significant CT parameters and clinical data from univariate analysis, and clinical symptom with jaundice (P = 0.005) was an independent predictor of ampullary carcinomas. For multivariate analysis using only significant CT parameters, abrupt narrowing of distal CBD was an independent predictor of ampullary carcinomas (P = 0.019). Among various CT criteria, abrupt narrowing of distal CBD and dilated IHD had highest sensitivity (77.4%) and highest accuracy (90.3%). The abrupt narrowing of distal CBD and dilated IHD is useful for differentiation of ampullary carcinomas from benign entity in patients without the presence of mass.
Paulus, Elena M; Fabian, Timothy C; Savage, Stephanie A; Zarzaur, Ben L; Botta, Vandana; Dutton, Wesley; Croce, Martin A
2014-02-01
Aggressive screening to diagnose blunt cerebrovascular injury (BCVI) results in early treatment, leading to improved outcomes and reduced stroke rates. While computed tomographic angiography (CTA) has been widely adopted for BCVI screening, evidence of its diagnostic sensitivity is marginal. Previous work from our institution using 32-channel multidetector CTA in 684 patients demonstrated an inadequate sensitivity of 51% (Ann Surg. 2011,253: 444-450). Digital subtraction angiography (DSA) continues to be the reference standard of diagnosis but has significant drawbacks of invasiveness and resource demands. There have been continued advances in CT technology, and this is the first report of an extensive experience with 64-channel multidetector CTA. Patients screened for BCVI using CTA and DSA (reference) at a Level 1 trauma center during the 12-month period ending in May 2012 were identified. Results of CTA and DSA, complications, and strokes were retrospectively reviewed and compared. A total of 594 patients met criteria for BCVI screening and underwent both CTA and DSA. One hundred twenty-eight patients (22% of those screened) had 163 injured vessels: 99 (61%) carotid artery injuries and 64 (39%) vertebral artery injuries. Sixty-four-channel CTA demonstrated an overall sensitivity per vessel of 68% and specificity of 92%. The 52 false-negative findings on CTA were composed of 34 carotid artery injuries and 18 vertebral artery injuries; 32 (62%) were Grade I injuries. Overall, positive predictive value was 36.2%, and negative predictive value was 97.5%. Six procedure-related complications (1%) occurred with DSA, including two iatrogenic dissections and one stroke. Sixty-four-channel CTA demonstrated a significantly improved sensitivity of 68% versus the 51% previously reported for the 32-channel CTA (p = 0.0075). Sixty-two percent of the false-negative findings occurred with low-grade injuries. Considering complications, cost, and resource demand associated with DSA, this study suggests that 64-channel CTA may replace DSA as the primary screening tool for BCVI. Diagnostic study, level III.
Zeltzer, Assaf A; Anzarut, Alexander; Braeckmans, Delphine; Seidenstuecker, Katrin; Hendrickx, Benoit; Van Hedent, Eddy; Hamdi, Moustapha
2017-09-01
A growing number of surgeons perform lymph node transfers for the treatment of lymphedema. When harvesting a vascularized lymph node groin flap (VGLNF) one of the major concerns is the potential risk of iatrogenic lymphedema of the donor-site. This article helps understanding of the lymph node distribution of the groin in order to minimize this risk. Fifty consecutive patients undergoing abdominal mapping by multi-detector CT scanner were included and 100 groins analyzed. The groin was divided in three zones (of which zone II is the safe zone) and lymph nodes were counted and mapped with their distances to anatomic landmarks. Further node units were plotted and counted. The average age was 48 years. A mean number of nodes of 6.5/groin was found. In zone II, which is our zone of interest a mean of 3.1 nodes were counted with a mean size of 7.8 mm. In three patients no nodes were found in zone II. In five patients nodes were seen in zone II but were not sufficient in size or number to be considered a lymph node unit. On average the lymph node unit in zone II was found to be 48.3 mm from the pubic tubercle when projected on a line from the pubic tubercle to the anterior superior iliac spine, 16.0 mm caudal to this line, and 20.4 mm above the groin crease. On average the lymph node unit was a mean of 41.7 mm lateral to the SCIV-SIEV confluence. This study provides increased understanding of the lymphatic anatomy in zone II of the groin flap and suggests a refined technique for designing the VGLNF. As with any flap there is a degree of individual patient variability. However, having information on the most common anatomy and flap design is of great value. © 2017 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ohno, T; Araki, F
2015-06-15
Purpose: To compare dosimetric properties and patient organ doses from four commercial multidetector CT (MDCT) using Monte Carlo (MC) simulation based on the absorbed dose measured using a Farmer chamber and cylindrical water phantoms according to AAPM TG-111. Methods: Four commercial MDCT were modeled using the GMctdospp (IMPS, Germany) based on the EGSnrc user code. The incident photon spectrum and bowtie filter for MC simulations were determined so that calculated values of aluminum half-value layer (Al-HVL) and off-center ratio (OCR) profile in air agreed with measured values. The MC dose was calibrated from absorbed dose measurements using a Farmer chambermore » and cylindrical water phantoms. The dose distributions of head, chest, and abdominal scan were calculated using patient CT images and mean organ doses were evaluated from dose volume histograms. Results: The HVLs at 120 kVp of Brilliance, LightSpeed, Aquilion, and SOMATOM were 9.1, 7.5, 7.2, and 8.7 mm, respectively. The calculated Al-HVLs agreed with measurements within 0.3%. The calculated and measured OCR profiles agreed within 5%. For adult head scans, mean doses for eye lens from Brilliance, LightSpeed, Aquilion, and SOMATOM were 21.7, 38.5, 47.2 and 28.4 mGy, respectively. For chest scans, mean doses for lung from Brilliance, LightSpeed, Aquilion, and SOMATOM were 21.1, 26.1, 35.3 and 24.0 mGy, respectively. For adult abdominal scans, the mean doses for liver from Brilliance, LightSpeed, Aquilion, and SOMATOM were 16.5, 21.3, 22.7, and 18.0 mGy, respectively. The absorbed doses increased with decreasing Al-HVL. The organ doses from Aquilion were two greater than those from Brilliance in head scan. Conclusion: MC dose distributions based on absorbed dose measurement in cylindrical water phantom are useful to evaluate individual patient organ doses.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Damilakis, John; Tzedakis, Antonis; Perisinakis, Kostas
Purpose: Current methods for the estimation of conceptus dose from multidetector CT (MDCT) examinations performed on the mother provide dose data for typical protocols with a fixed scan length. However, modified low-dose imaging protocols are frequently used during pregnancy. The purpose of the current study was to develop a method for the estimation of conceptus dose from any MDCT examination of the trunk performed during all stages of gestation. Methods: The Monte Carlo N-Particle (MCNP) radiation transport code was employed in this study to model the Siemens Sensation 16 and Sensation 64 MDCT scanners. Four mathematical phantoms were used, simulatingmore » women at 0, 3, 6, and 9 months of gestation. The contribution to the conceptus dose from single simulated scans was obtained at various positions across the phantoms. To investigate the effect of maternal body size and conceptus depth on conceptus dose, phantoms of different sizes were produced by adding layers of adipose tissue around the trunk of the mathematical phantoms. To verify MCNP results, conceptus dose measurements were carried out by means of three physical anthropomorphic phantoms, simulating pregnancy at 0, 3, and 6 months of gestation and thermoluminescence dosimetry (TLD) crystals. Results: The results consist of Monte Carlo-generated normalized conceptus dose coefficients for single scans across the four mathematical phantoms. These coefficients were defined as the conceptus dose contribution from a single scan divided by the CTDI free-in-air measured with identical scanning parameters. Data have been produced to take into account the effect of maternal body size and conceptus position variations on conceptus dose. Conceptus doses measured with TLD crystals showed a difference of up to 19% compared to those estimated by mathematical simulations. Conclusions: Estimation of conceptus doses from MDCT examinations of the trunk performed on pregnant patients during all stages of gestation can be made using the method developed in the current study.« less
Accessible or Inaccessible? Diagnostic Efficacy of CT-Guided Core Biopsies of Head and Neck Masses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cunningham, Jane D., E-mail: janecunningham0708@gmail.com; McCusker, Mark W.; Power, Sarah
PurposeTissue sampling of lesions in the head and neck is challenging due to complex regional anatomy and sometimes necessitates open surgical biopsy. However, many patients are poor surgical candidates due to comorbidity. Thus, we evaluated the use of CT guidance for establishing histopathological diagnosis of head and neck masses.MethodsAll consecutive patients (n = 22) who underwent CT-guided core biopsy of head or neck masses between April 2009 and August 2012 were retrospectively reviewed using the departmental CT interventional procedures database. The indication for each biopsy performed was to establish or exclude a diagnosis of neoplasia in patients with suspicious head or neckmore » lesions found on clinical examination or imaging studies. Patients received conscious sedation and 18 G, semiautomated core needle biopsies were performed by experienced neuroradiologists using 16-slice multidetector row CT imaging guidance (Somatom Definition Siemens Medical Solutions, Germany). Histopathology results of each biopsy were analysed.ResultsSixteen of 22 biopsies that were performed (73 %) yielded a pathological diagnosis. Anatomic locations biopsied included: masticator (n = 7), parapharyngeal (n = 3), parotid (n = 3), carotid (n = 3), perivertebral (n = 3), pharyngeal (n = 2), and retropharyngeal (n = 1) spaces. Six biopsies (27 %) were nondiagnostic due to inadequate tissue sampling, particularly small biopsy sample size and failure to biopsy the true sampling site due to extensive necrosis. No major complications were encountered.ConclusionsThe use of CT guidance to perform core biopsies of head and neck masses is an effective means of establishing histopathological diagnosis and reduces the need for diagnostic open surgical biopsy and general anaesthesia.« less
Ito, M; Oishi, R; Fukunaga, M; Sone, T; Sugimoto, T; Shiraki, M; Nishizawa, Y; Nakamura, T
2014-03-01
Once-weekly administration of 56.5 μg teriparatide improved cortical bone parameters and biomechanical parameters at the proximal femur by CT geometry analysis. The aim of this study was to evaluate the effects of weekly administration of teriparatide [human PTH (1-34)] on bone geometry, volumetric bone mineral density (vBMD), and parameters of bone strength at the proximal femur which were longitudinally investigated using computed tomography (CT). The subjects were a subgroup of a recent, randomly assigned, double-blind study (578 subjects) comparing the anti-fracture efficacy of a once-weekly subcutaneous injection of 56.5 μg teriparatide with placebo (TOWER trial). Sixty-six ambulatory postmenopausal women with osteoporosis were enrolled at 15 study sites having multi-detector row CT, and included women injected with teriparatide (n = 29, 74.2 ± 5.1 years) or with placebo (n = 37, 74.8 ± 5.3 years). CT data were obtained at baseline and follow-up scans were performed at 48 and 72 weeks. The data were analyzed to obtain cross-sectional densitometric, geometric, and biomechanical parameters including the section modulus (SM) and buckling ratio (BR) of the femoral neck, inter-trochanter, and femoral shaft. We found that once-weekly teriparatide increased cortical thickness/cross-sectional area (CSA) and total area, and improved biomechanical properties (i.e., decreasing BR) at the femoral neck and shaft. Teriparatide did not change the cortical perimeter. Our longitudinal analysis of proximal femur geometry by CT revealed that once-weekly administration of 56.5 μg teriparatide improved cortical bone parameters at the femoral neck and shaft and also improved biomechanical parameters.
Lee, Sangyun; Kwon, Heejin; Cho, Jihan
2016-12-01
To investigate image quality characteristics of abdominal computed tomography (CT) scans reconstructed with adaptive statistical iterative reconstruction V (ASIR-V) vs currently using applied adaptive statistical iterative reconstruction (ASIR). This institutional review board-approved study included 35 consecutive patients who underwent CT of the abdomen. Among these 35 patients, 27 with focal liver lesions underwent abdomen CT with a 128-slice multidetector unit using the following parameters: fixed noise index of 30, 1.25 mm slice thickness, 120 kVp, and a gantry rotation time of 0.5 seconds. CT images were analyzed depending on the method of reconstruction: ASIR (30%, 50%, and 70%) vs ASIR-V (30%, 50%, and 70%). Three radiologists independently assessed randomized images in a blinded manner. Imaging sets were compared to focal lesion detection numbers, overall image quality, and objective noise with a paired sample t test. Interobserver agreement was assessed with the intraclass correlation coefficient. The detection of small focal liver lesions (<10 mm) was significantly higher when ASIR-V was used when compared to ASIR (P <0.001). Subjective image noise, artifact, and objective image noise in liver were generally significantly better for ASIR-V compared to ASIR, especially in 50% ASIR-V. Image sharpness and diagnostic acceptability were significantly worse in 70% ASIR-V compared to various levels of ASIR. Images analyzed using 50% ASIR-V were significantly better than three different series of ASIR or other ASIR-V conditions at providing diagnostically acceptable CT scans without compromising image quality and in the detection of focal liver lesions. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Jeng, Toh Charng; Haspani, Mohd Saffari Mohd; Adnan, Johari Siregar; Naing, Nyi Nyi
2008-01-01
A repeat Computer Tomographic (CT) brain after 24–48 hours from the 1st scanning is usually practiced in most hospitals in South East Asia where intracranial pressure monitoring (ICP) is routinely not done. This interval for repeat CT would be shortened if there was a deterioration in Glasgow Coma Scale (GCS). Most of the time the prognosis of any intervention may be too late especially in hospitals with high patient-to-doctor ratio causing high mortality and morbidity. The purpose of this study was to determine the important predictors for early detection of Delayed Traumatic Intracranial Haemorrhage (DTICH) and Progressive Traumatic Brain Injury (PTBI) before deterioration of GCS occurred, as well as the most ideal timing of repeated CT brain for patients admitted in Malaysian hospitals. A total of 81 patients were included in this study over a period of six months. The CT scan brain was studied by comparing the first and second CT brain to diagnose the presence of DTICH/PTBI. The predictors tested were categorised into patient factors, CT brain findings and laboratory investigations. The mean age was 33.1 ± 15.7 years with a male preponderance of 6.36:1. Among them, 81.5% were patients from road traffic accidents with Glasgow Coma Scale ranging from 4 – 15 (median of 12) upon admission. The mean time interval delay between trauma and first CT brain was 179.8 ± 121.3 minutes for the PTBI group. The DTICH group, 9.9% of the patients were found to have new intracranial clots. Significant predictors detected were different referral hospitals (p=0.02), total GCS status (p=0.026), motor component of GCS (p=0.043), haemoglobin level (p<0.001), platelet count (p=0.011) and time interval between trauma and first CT brain (p=0.022). In the PTBI group, 42.0% of the patients were found to have new changes (new clot occurrence, old clot expansion and oedema) in the repeat CT brain. Univariate statistical analysis revealed that age (p=0.03), race (p=0.035), types of admission (p=0.024), GCS status (p=0.02), pupillary changes (p=0.014), number of intracranial lesion (p=0.004), haemoglobin level (p=0.038), prothrombin time (p=0.016) as the best predictors of early detection of changes. Multiple logistics regression analysis indicated that age, severity, GCS status (motor component) and GCS during admission were significantly associated with second CT scan with changes. This study showed that 9.9% of the total patients seen in the period of study had DTICH and 42% had PTBI. In the early period after traumatic head injury, the initial CT brain did not reveal the full extent of haemorrhagic injury and associated cerebral oedema. Different referral hospitals of different trauma level, GCS status, motor component of the GCS, haemoglobin level, platelet count and time interval between trauma and the first CT brain were the significant predictors for DTICH. Whereas the key determinants of PTBI were age, race, types of admission, GCS status, pupillary changes, number of intracranial bleed, haemoglobin level, prothrombin time and of course time interval between trauma and first CT brain. Any patients who had traumatic head injury in hospitals with no protocol of repeat CT scan or intracranial pressure monitoring especially in developing countries are advised to have to repeat CT brain at the appropriate quickest time . PMID:22589639
Plasma level of cardiotrophin-1 as a prognostic predictor in patients with chronic heart failure.
Tsutamoto, Takayoshi; Asai, Shigeru; Tanaka, Toshinari; Sakai, Hiroshi; Nishiyama, Keizo; Fujii, Masanori; Yamamoto, Takashi; Ohnishi, Masato; Wada, Atsuyuki; Saito, Yoshihiko; Horie, Minoru
2007-10-01
Cardiotrophin-1 (CT-1) is a member of the interleukin (IL-6) family of cytokines and is increased in patients with chronic heart failure (CHF). To evaluate the prognostic role of CT-1 in patients with CHF. We measured the plasma levels of CT-1, brain natriuretic peptide (BNP), and IL-6 in 125 patients with CHF. Patients were monitored for a mean follow-up period of 2.9 years. Plasma levels of CT-1 increased with severity of CHF. There was a significant negative correlation between plasma CT-1 and left ventricular ejection fraction. There was a significant correlation between plasma CT-1 and log IL-6. During the follow-up period, 37 patients died. High plasma levels of CT-1, BNP, and IL-6 were independent predictors of mortality on stepwise multivariate analysis. The hazard ratio for mortality in patients with plasma BNP>170 pg/mL and CT-1>658 fmol/mL was 2.48 (95% confidence interval, 1.217-5.060) compared to those with plasma BNP>170 pg/mL and CT-1<658 fmol/mL (p=0.0124). These findings indicate that plasma CT-1 measurement provides additional prognostic information and that combined levels of CT-1 and BNP are more accurate at predicting mortality in patients with CHF than either marker alone.
SU-F-207-03: Dosimetric Effect of the Position of Arms in Torso CT Scan with Tube Current Modulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, H; Rensselaer Polytechnic Institute, Troy, NY; Gao, Y
Purpose: To evaluate the patient organ dose differences between the arms-raised and arms-lowered postures in Torso multidetector computed tomography (MDCT) scan protocols with tube current modulation (TCM). Methods: Patient CT organ doses were simulated using the Monte Carlo method with human phantoms and a validated CT scanner model. A set of adult human phantoms with arms raised and arms lowered postures were developed using advanced BREP-based mesh surface geometries. Organ doses from routine Torso scan protocols such as chest, abdomen-pelvis, and CAP scans were simulated. The organ doses differences caused by two different posutres were investigated when tube current modulationmore » (TCM) were applied during the CT scan. Results: With TCM applied, organ doses of all the listed organs of arms-lowered posture phantom are larger than those of arms raised phantom. The dose difference for most of the organs or tissues are larger than 50%, and the skin doses difference for abdomen-pelvis scan even reaches 112.03%. This is due to the fact that the tube current for patient with arms-lowered is much higher than for the arms raised posture. Conclusion: Considering CT scan with TCM, which is commonly applied clinically, patients who could not raise their arms will receive higher radiation dose than the arms raised patient, with dose differences for some tissues such as the skin being larger than 100%. This is due to the additional tube current necessary to penetrate the arms while maintaining consistent image quality. National Nature Science Foundation of China(No.11475047)« less
Berkenblit, Robert; Hoenig, David; Lerer, Daniel; Moses, Melanie; Minsky, Lloyd
2013-02-01
CT has become a well-established modality in the evaluation of urinary calculi. The advent of multidetector CT (MDCT) scanners and submillimeter thick slice acquisitions has yielded CT images with even greater resolution. MDCT scanners allow for source data slice acquisition with submillimeter slice thickness. These source images can then be reconstructed to thicker slices for more convenient interpretation of the CT scan. Previous authors have looked at the effect of slice thickness on detection of urinary calculi. We investigated whether the thin slice source images yielded detection of additional stones and the potential significance of detecting these additional stones. Ninety-five consecutive patients who were referred to our outpatient imaging center for CT, with a clinical history placing them at risk for urinary calculi, were included in the study. In 49 (52%) of the 95 patients, more calculi were visualized using the 0.625-mm thick images than with the 5-mm thick images. In 34 (69%) of these 49 patients, the additional findings were thought to be "clinically significant," while in the remaining 15 (31%) patients, the additional findings were not thought to be clinically significant. In 46 (48%) of the 95 patients, there were no additional urinary calculi identified on the 0.625-mm thick images compared with that observed on 5-mm thick images. The results from this study encourage reviewing the thin slice source images of MDCTs in patients at risk for urinary calculi, because important clinical decisions may hinge on the additional findings made on these images.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ho, Yick Wing, E-mail: mpr@hksh.com; Wong, Wing Kei Rebecca; Yu, Siu Ki
2012-01-01
To evaluate the accuracy in detection of small and low-contrast regions using a high-definition diagnostic computed tomography (CT) scanner compared with a radiotherapy CT simulation scanner. A custom-made phantom with cylindrical holes of diameters ranging from 2-9 mm was filled with 9 different concentrations of contrast solution. The phantom was scanned using a 16-slice multidetector CT simulation scanner (LightSpeed RT16, General Electric Healthcare, Milwaukee, WI) and a 64-slice high-definition diagnostic CT scanner (Discovery CT750 HD, General Electric Healthcare). The low-contrast regions of interest (ROIs) were delineated automatically upon their full width at half maximum of the CT number profile inmore » Hounsfield units on a treatment planning workstation. Two conformal indexes, CI{sub in}, and CI{sub out}, were calculated to represent the percentage errors of underestimation and overestimation in the automated contours compared with their actual sizes. Summarizing the conformal indexes of different sizes and contrast concentration, the means of CI{sub in} and CI{sub out} for the CT simulation scanner were 33.7% and 60.9%, respectively, and 10.5% and 41.5% were found for the diagnostic CT scanner. The mean differences between the 2 scanners' CI{sub in} and CI{sub out} were shown to be significant with p < 0.001. A descending trend of the index values was observed as the ROI size increases for both scanners, which indicates an improved accuracy when the ROI size increases, whereas no observable trend was found in the contouring accuracy with respect to the contrast levels in this study. Images acquired by the diagnostic CT scanner allow higher accuracy on size estimation compared with the CT simulation scanner in this study. We recommend using a diagnostic CT scanner to scan patients with small lesions (<1 cm in diameter) for radiotherapy treatment planning, especially for those pending for stereotactic radiosurgery in which accurate delineation of small-sized, low-contrast regions is important for dose calculation.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Long, Daniel J.; Lee, Choonsik; Tien, Christopher
2013-01-15
Purpose: To validate the accuracy of a Monte Carlo source model of the Siemens SOMATOM Sensation 16 CT scanner using organ doses measured in physical anthropomorphic phantoms. Methods: The x-ray output of the Siemens SOMATOM Sensation 16 multidetector CT scanner was simulated within the Monte Carlo radiation transport code, MCNPX version 2.6. The resulting source model was able to perform various simulated axial and helical computed tomographic (CT) scans of varying scan parameters, including beam energy, filtration, pitch, and beam collimation. Two custom-built anthropomorphic phantoms were used to take dose measurements on the CT scanner: an adult male and amore » 9-month-old. The adult male is a physical replica of University of Florida reference adult male hybrid computational phantom, while the 9-month-old is a replica of University of Florida Series B 9-month-old voxel computational phantom. Each phantom underwent a series of axial and helical CT scans, during which organ doses were measured using fiber-optic coupled plastic scintillator dosimeters developed at University of Florida. The physical setup was reproduced and simulated in MCNPX using the CT source model and the computational phantoms upon which the anthropomorphic phantoms were constructed. Average organ doses were then calculated based upon these MCNPX results. Results: For all CT scans, good agreement was seen between measured and simulated organ doses. For the adult male, the percent differences were within 16% for axial scans, and within 18% for helical scans. For the 9-month-old, the percent differences were all within 15% for both the axial and helical scans. These results are comparable to previously published validation studies using GE scanners and commercially available anthropomorphic phantoms. Conclusions: Overall results of this study show that the Monte Carlo source model can be used to accurately and reliably calculate organ doses for patients undergoing a variety of axial or helical CT examinations on the Siemens SOMATOM Sensation 16 scanner.« less
Role of (68)Ga-DOTATATE PET/CT in patients with multiple endocrine neoplasia type 1 (MEN1).
Lastoria, Secondo; Marciello, Francesca; Faggiano, Antongiulio; Aloj, Luigi; Caracò, Corradina; Aurilio, Michela; D'Ambrosio, Laura; Di Gennaro, Francesca; Ramundo, Valeria; Camera, Luigi; De Luca, Leonardo; Fonti, Rosa; Napolitano, Vincenzo; Colao, Annamaria
2016-06-01
Multiple endocrine neoplasia type 1 (MEN1) is a hereditary syndrome predisposing to many endocrine and neuroendocrine tumors (NET). Conventional imaging (CI) cannot provide satisfactory results for all the different types of MEN1-related tumors. Objective of this prospective observational study was to evaluate the role of (68)Ga-DOTATATE PET/CT in MEN1 compared to CI. Diagnostic performance of (68)Ga-DOTATATE PET/CT for the detection of NET was evaluated as well as the prognostic role of SUVmax. Eighteen patients with genetically confirmed MEN1 were evaluated by (68)Ga-DOTATATE PET/CT, endoscopic ultrasounds, multidetector-row computed tomography, magnetic resonance imaging, and hormone/markers serum measurements. Four MEN1-related tumor sites (pancreas, pituitary, parathyroids, adrenals) were considered. Sensitivity and specificity of (68)Ga-DOTATATE PET/CT for the detection of NET were calculated. There was (68)Ga-DOTATATE PET/CT uptake in 11/11 patients with pancreatic lesions, in 9/12 with pituitary adenoma, in 5/15 with parathyroid enlargements, and in 5/7 with adrenal lesions. (68)Ga-DOTATATE PET/CT showed sensitivity and specificity of 100 and 100 % in pancreas, 75 and 83 % in pituitary, 28 and 100 % in parathyroids, and 62.5 and 100 % in adrenals, respectively. Compared with CI, no significant difference in sensitivity for pancreas, pituitary, and adrenals was found, while CI had a better sensitivity for parathyroids (p = 0.002). On the ROC analysis, progression of pancreatic lesions was significantly associated to SUVmax <12.3 (p < 0.05). (68)Ga-DOTATATE PET/CT is greatly helpful in the work-up of MEN1 providing a panoramic view of MEN1-related lesions. There is also a prognostic role of (68)Ga-PET in patients with MEN1-pancreatic lesions.
Martini, K; Becker, A S; Guggenberger, R; Andreisek, G; Frauenfelder, T
2016-07-01
To determine the diagnostic performance of tomosynthesis in depicting osteoarthritic lesions in comparison to conventional radiographs, with use of computed tomography (CT) as standard-of-reference. Imaging of 12 cadaveric hands was performed with tomosynthesis in dorso-palmar (dp) projection, conventional radiographs (dp) and multi-detector CT. Distal interphalangeal joint (DIP)II, DIPIII, proximal interphalangeal joint (PIP)II, PIPIII, first carpometacarpal (CMC) and scaphotrapezotrapezoidal joint (STT) were graded by two independent readers using the Osteoarthritis Research Society International (OARSI) score. The mean score for each feature was calculated for all modalities. Additional wrists were evaluated for presence of calcium pyrophosphate disease (CPPD). CT served as reference-standard. Inter-reader agreement (ICC) was calculated. Comparing tomosynthesis and conventional radiographs to CT, the sensitivity for the presence of osteophytes was 95,7% vs 65,2%; for joint space narrowing 95,8% vs 52,1%; for subchondral sclerosis 61,5% vs 51,3%; for lateral deformity 83.3% vs 83,3%; and for subchondral cysts 45,8% vs 29,2%. Erosions were not present. While tomosynthesis showed no significant difference in OARSI score grading to CT (mean OARSI-score CT: 16.8, SD = 10.6; mean OARSI-score Tomosynthesis: 16.3, SD = 9.6; P = 0.84), conventional radiographs had significant lower mean OARSI scores (mean OARSI-score X-ray: 11.1, SD = 8.3; P = 0.04). Inter-reader agreement for OARSI scoring was excellent (ICC = 0.99). CPPD calcifications present in CT, were also visible with tomosynthesis, but not with conventional radiography. In conclusion, tomosynthesis depicts more osteoarthritic changes in the small joints of the hand than conventional radiography using the OARSI scoring system and CT as the standard of reference. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Huang, Yu-Sen; Hsu, Hsao-Hsun; Chen, Jo-Yu; Tai, Mei-Hwa; Jaw, Fu-Shan; Chang, Yeun-Chung
2014-01-01
This study strived to evaluate the relationship between degree of pulmonary emphysema and cardiac ventricular function in chronic obstructive pulmonary disease (COPD) patients with pulmonary hypertension (PH) using electrocardiographic-gated multidetector computed tomography (CT). Lung transplantation candidates with the diagnosis of COPD and PH were chosen for the study population, and a total of 15 patients were included. The extent of emphysema is defined as the percentage of voxels below -910 Hounsfield units in the lung windows in whole lung CT without intravenous contrast. Heart function parameters were measured by electrocardiographic-gated CT angiography. Linear regression analysis was conducted to examine the associations between percent emphysema and heart function indicators. Significant correlations were found between percent emphysema and right ventricular (RV) measurements, including RV end-diastolic volume (R(2) = 0.340, p = 0.023), RV stroke volume (R(2) = 0.406, p = 0.011), and RV cardiac output (R(2) = 0.382, p = 0.014); the correlations between percent emphysema and left ventricular function indicators were not observed. The study revealed that percent emphysema is correlated with RV dysfunction among COPD patients with PH. Based on our findings, percent emphysema can be considered for use as an indicator to predict the severity of right ventricular dysfunction among COPD patients.
ZHU, CAISONG; LIU, WEI; YANG, JUN; YANG, JING; SHAO, KANGWEI; YUAN, LIXIN; CHEN, HAIRONG; LU, WEI; ZHU, YING
2016-01-01
The aim of the present study was to compare the multidetector computed tomography (MDCT) features of benign and malignant nodules in patients with chronic lymphocytic thyroiditis (CLT). MDCT findings, including the size, solid percentage, calcification, margin, capsule, anteroposterior-transverse diameter ratio as well as the mode and the degree of enhancement of 137 thyroid nodules in 127 CLT cases were retrospectively analyzed. Furthermore, the correlation between MDCT findings and pathological results combined with the CT perfusion imaging was analyzed for the differences between benign and malignant nodules. A total of 77.5% (31/40) of malignant nodules were completely solid, and 33% (32/97) of benign nodules were predominantly cystic. Compared with the benign nodules, micro-calcification and internal calcification were more frequently observed in the malignant nodules (P<0.05). MDCT features such as ill-defined margin, absence of capsule or incomplete capsule or homogeneous enhancement were more likely to be present in the malignant nodules (P<0.05). Nevertheless, no significant difference was observed in the enhancement degree at arterial or venous phase between benign and malignant nodules (P>0.05). MDCT features are useful in differentiating the benign and malignant nodules in CLT patients, and it may be essential for a radiologist to review the MDCT characteristics of nodules in the clinical practice. PMID:27347131
Ogura, I; Kaneda, T; Sasaki, Y; Buch, K; Sakai, O
2015-06-01
Temporal bone fracture after mandibular trauma is thought to be rare, and its prevalence has not been reported in the literature. The purpose of this study was to investigate the prevalence of temporal bone fractures in patients with mandibular fractures and the relationship between temporal bone fractures and the mandibular fracture location using multidetector-row computed tomography (MDCT). A prospective study was performed in 201 patients with mandibular fractures who underwent 64-MDCT scans. The mandibular fracture locations were classified as median, paramedian, angle, and condylar types. Statistical analysis for the relationship between prevalence of temporal bone fractures and mandibular fracture locations was performed using χ(2) test with Fisher's exact test. A P-value < 0.05 was considered statistically significant. The percentage of cases with temporal bone fracture was 3.0 % of all patients with mandibular fractures and 19.0 % of those with multiple mandibular fractures of paramedian and condylar type. There was a significant relationship between the incidence of temporal bone fracture and the paramedian- and condylar-type mandibular fracture (P = 0.001). Multiple mandibular fractures of paramedian and condylar type may be a stronger indicator for temporal bone fractures. This study suggests that patients with mandibular fracture, especially the paramedian and condylar type, should be examined for coexisting temporal bone fracture using MDCT.
Antunes, Sofia; Esposito, Antonio; Palmisano, Anna; Colantoni, Caterina; Cerutti, Sergio; Rizzo, Giovanna
2016-05-01
Extraction of the cardiac surfaces of interest from multi-detector computed tomographic (MDCT) data is a pre-requisite step for cardiac analysis, as well as for image guidance procedures. Most of the existing methods need manual corrections, which is time-consuming. We present a fully automatic segmentation technique for the extraction of the right ventricle, left ventricular endocardium and epicardium from MDCT images. The method consists in a 3D level set surface evolution approach coupled to a new stopping function based on a multiscale directional second derivative Gaussian filter, which is able to stop propagation precisely on the real boundary of the structures of interest. We validated the segmentation method on 18 MDCT volumes from healthy and pathologic subjects using manual segmentation performed by a team of expert radiologists as gold standard. Segmentation errors were assessed for each structure resulting in a surface-to-surface mean error below 0.5 mm and a percentage of surface distance with errors less than 1 mm above 80%. Moreover, in comparison to other segmentation approaches, already proposed in previous work, our method presented an improved accuracy (with surface distance errors less than 1 mm increased of 8-20% for all structures). The obtained results suggest that our approach is accurate and effective for the segmentation of ventricular cavities and myocardium from MDCT images.
Martina, Maria Cristina; Cesarani, Federico; Boano, Rosa; Fiore Marochetti, Elisa; Gandini, Giovanni
The objective of our work was to report the most recent findings obtained with multidetector computed tomography of a child mummy from the Roman period (119-123 CE) housed at the Egyptian Museum in Turin, Italy. Multidetector computed tomography and postprocessing were applied to understand the embalming techniques, the nature of a foreign object, and anthropometrical values. The information was compared with that from other mummies that were buried in the same tomb, but today housed in different museums. New information regarding the embalming technique was revealed. Multidetector computed tomography allowed the identification of a knife-like metallic object, probably an amulet for the child's protection in the afterlife. Multidetector computed tomography and image postprocessing confirm their valuable role in noninvasive studies in ancient mummies and provided evidence of a unique cultural practice in the late history of Ancient Egypt such as placing a knife possibly as an amulet.
Graham, R N J
2012-01-01
With the increasing tempo of military conflicts in the last decade, much has been learnt about imaging battlefield casualties in the acute setting. Ultrasound in the form of focused abdominal sonography in trauma (FAST) has proven invaluable in emergency triage of patients for immediate surgery. Multidetector CT allows accurate determination of battlefield trauma injuries. It permits the surgeons and anaesthetists to plan their interventions more thoroughly and to be made aware of clinically occult injuries. There are common injury patterns associated with blast injury, gunshot wounds and blunt trauma. While this body of knowledge is most applicable to the battlefield, there are parallels with peacetime radiology, particularly in terrorist attacks and industrial accidents. This pictorial review is based on the experiences of a UK radiologist deployed in Afghanistan in 2010. PMID:22806621
PHACES syndrome associated with carcinoid endobronchial tumor.
Mama, Nadia; H'mida, Dorra; Lahmar, Imen; Yacoubi, Mohamed Tahar; Tlili-Graiess, Kalthoum
2014-05-01
PHACES syndrome consists of the constellation of manifestations including posterior fossa anomalies of the brain (most commonly Dandy-Walker malformations), hemangiomas of the face and scalp, arterial abnormalities, cardiac defects, eye anomalies and sternal defects. We present a case with a possible PHACES syndrome including sternal cleft and supraumbilical raphé, precordial skin tag, persistent left superior vena cava and subtle narrowing of the aorta with an endobronchial carcinoid tumor. All these anomalies were discovered on chest multi-detector CT. This is a unique case of PHACES syndrome associated with carcinoid tumor. Review of the literature revealed 3 cases of PHACES syndrome with glial tumor. The authors tried to find the relationship between PHACES syndrome and carcinoid tumors or gliomas, which all derive from the neural crest cells.
Khalique, Omar K; Hahn, Rebecca T; Gada, Hemal; Nazif, Tamim M; Vahl, Torsten P; George, Isaac; Kalesan, Bindu; Forster, Molly; Williams, Mathew B; Leon, Martin B; Einstein, Andrew J; Pulerwitz, Todd C; Pearson, Gregory D N; Kodali, Susheel K
2014-08-01
This study sought to determine the impact of quantity and location of aortic valve calcification (AVC) on paravalvular regurgitation (PVR) and rates of post-dilation (PD) immediately after transcatheter aortic valve replacement (TAVR). The impact of AVC in different locations within the aortic valve complex is incompletely understood. This study analyzed 150 patients with severe, symptomatic aortic stenosis who underwent TAVR. Total AVC volume scores were calculated from contrast-enhanced multidetector row computed tomography imaging. AVC was divided by leaflet sector and region (Leaflet, Annulus, left ventricular outflow tract [LVOT]), and a combination of LVOT and Annulus (AnnulusLVOT). Asymmetry was assessed. Receiver-operating characteristic analysis was performed with greater than or equal to mild PVR and PD as classification variables. Logistic regression was performed. Quantity of and asymmetry of AVC for all regions of the aortic valve complex predicted greater than or equal to mild PVR by receiver-operating characteristic analysis (area under the curve = 0.635 to 0.689), except Leaflet asymmetry. Receiver-operating characteristic analysis for PD was significant for quantity and asymmetry of AVC in all regions, with higher area under the curve values than for PVR (area under the curve = 0.648 to 0.741). On multivariable analysis, Leaflet and AnnulusLVOT calcification were independent predictors of both PVR and PD regardless of multidetector row computed tomography area cover index. Quantity and asymmetry of AVC in all regions of the aortic valve complex predict greater than or equal to mild PVR and performance of PD, with the exception of Leaflet asymmetry. Quantity of AnnulusLVOT and Leaflet calcification independently predict PVR and PD when taking into account multidetector row computed tomography area cover index. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Prieto-Peña, Diana; Martínez-Rodríguez, Isabel; Loricera, Javier; Banzo, Ignacio; Calderón-Goercke, Mónica; Calvo-Río, Vanesa; González-Vela, Carmen; Corrales, Alfonso; Castañeda, Santos; Blanco, Ricardo; Hernández, José L; González-Gay, Miguel Á
2018-05-18
Polymyalgia rheumatica (PMR) is often the presenting manifestation of giant cell arteritis (GCA). Fluorine-18-fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) scan often discloses the presence of large vessel vasculitis (LVV) in PMR patients. We aimed to identify predictive factors of a positive PET/CT scan for LVV in patients classified as having isolated PMR according to well-established criteria. A set of consecutive patients with PMR from a single hospital were assessed. All of them underwent PET/CT scan between January 2010 and February 2018 based on clinical considerations. Patients with PMR associated to other diseases, including those with cranial features of GCA, were excluded. The remaining patients were categorized in classic PMR (if fulfilled the 2012 EULAR/ACR classification criteria at disease diagnosis; n = 84) or atypical PMR (who did not fulfill these criteria; n = 16). Only information on patients with classic PMR was assessed. The mean age of the 84 patients (51 women) with classic PMR was 71.4 ± 9.2 years. A PET/CT scan was positive in 51 (60.7%). Persistence of classic PMR symptoms was the most common reason to perform a PET/CT scan. Nevertheless, patients with positive PET/CT scan often had unusual symptoms. The best set of predictors of a positive PET/CT scan were bilateral diffuse lower limb pain (OR = 8.8, 95% CI: 1.7-46.3; p = 0.01), pelvic girdle pain (OR = 4.9, 95% CI: 1.50-16.53; p = 0.01) and inflammatory low back pain (OR = 4.7, 95% CI: 1.03-21.5; p = 0.04). Inflammatory low back pain, pelvic girdle and diffuse lower limb pain are predictors of positive PET/CT scan for LVV in PMR. Copyright © 2018 Elsevier Inc. All rights reserved.
Avanesov, Maxim; Weinrich, Julius M; Kraus, Thomas; Derlin, Thorsten; Adam, Gerhard; Yamamura, Jin; Karul, Murat
2016-11-01
The purpose of the retrospective study was to evaluate the additional value of dual-phase multidetector computed tomography (MDCT) protocols over a single-phase protocol on initial MDCT in patients with acute pancreatitis using three CT-based pancreatitis severity scores with regard to radiation dose. In this retrospective, IRB approved study MDCT was performed in 102 consecutive patients (73 males; 55years, IQR48-64) with acute pancreatitis. Inclusion criteria were CT findings of interstitial edematous pancreatitis (IP) or necrotizing pancreatitis (NP) and a contrast-enhanced dual-phase (arterial phase and portal-venous phase) abdominal CT performed at ≥72h after onset of symptoms. The severity of pancreatic and extrapancreatic changes was independently assessed by 2 observers using 3 validated CT-based scoring systems (CTSI, mCTSI, EPIC). All scores were applied to arterial phase and portal venous phase scans and compared to score results of portal venous phase scans, assessed ≥14days after initial evaluation. For effective dose estimation, volume CT dose index (CTDIvol) and dose length product (DLP) were recorded in all examinations. In neither of the CT severity scores a significant difference was observed after application of a dual-phase protocol compared with a single-phase protocol (IP: CTSI: 2.7 vs. 2.5, p=0.25; mCTSI: 4.0 vs. 4.0, p=0.10; EPIC: 2.0 vs. 2.0, p=0.41; NP: CTSI: 8.0 vs. 7.0, p=0.64; mCTSI: 8.0 vs. 8.0, p=0.10; EPIC: 3.0 vs. 3.0, p=0.06). The application of a single-phase CT protocol was associated with a median effective dose reduction of 36% (mean dose reduction 31%) compared to a dual-phase CT scan. An initial dual-phase abdominal CT after ≥72h after onset of symptoms of acute pancreatitis was not superior to a single-phase protocol for evaluation of the severity of pancreatic and extrapancreatic changes. However, the effective radiation dose may be reduced by 36% using a single-phase protocol. Copyright © 2016. Published by Elsevier Ireland Ltd.
Functional Imaging of the Lungs with Gas Agents
Kruger, Stanley J.; Nagle, Scott K.; Couch, Marcus J.; Ohno, Yoshiharu; Albert, Mitchell; Fain, Sean B.
2015-01-01
This review focuses on the state-of-the-art of the three major classes of gas contrast agents used in magnetic resonance imaging (MRI) – hyperpolarized (HP) gas, molecular oxygen, and fluorinated gas – and their application to clinical pulmonary research. During the past several years there has been accelerated development of pulmonary MRI. This has been driven in part by concerns regarding ionizing radiation using multi-detector computed tomography (CT). However, MRI also offers capabilities for fast multi-spectral and functional imaging using gas agents that are not technically feasible with CT. Recent improvements in gradient performance and radial acquisition methods using ultra-short echo time (UTE) have contributed to advances in these functional pulmonary MRI techniques. Relative strengths and weaknesses of the main functional imaging methods and gas agents are compared and applications to measures of ventilation, diffusion, and gas exchange are presented. Functional lung MRI methods using these gas agents are improving our understanding of a wide range of chronic lung diseases, including chronic obstructive pulmonary disease (COPD), asthma, and cystic fibrosis (CF) in both adults and children. PMID:26218920
Chami, H A; Faraj, W; Yehia, Z A; Badour, S A; Sawan, P; Rebeiz, K; Safa, R; Saade, C; Ghandour, B; Shamseddine, A; Mukherji, D; Haydar, A A
2015-12-01
To evaluate the association of quantitative computed tomography (CT) measures of emphysema with the occurrence of pneumothorax after CT-guided needle lung biopsy (NLB) accounting for other risk factors. One hundred and sixty-three CT-guided NLBs performed between 2008 and 2013 with available complete chest CT within 30 days were reviewed for the occurrence of post-procedure pneumothorax. Percent emphysema was determined quantitatively as the percentage of lung voxels below -950 HU on chest CT images using automated software. Multivariable regression was used to assess the association of percent emphysema volume with the occurrence of post-procedure pneumothorax. The association of percent emphysema volume with the pneumothorax size and need for chest tube placement after NLB was also explored. Percent emphysema was significantly associated with the incidence of post-NLB pneumothorax (OR=1.10 95% confidence interval: 1.01-1.15; p=0.03) adjusting for lower-lobe lesion location, needle path length, lesion size, number of passes, and pleural needle trajectory angle. Percent emphysema was not associated with the size of the pneumothorax, nor the need for chest tube placement after NLB. Percent emphysema determined quantitatively from chest CT is a significant predictor of post-NLB pneumothorax. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Physiological and computed tomographic predictors of outcome from lung volume reduction surgery.
Washko, George R; Martinez, Fernando J; Hoffman, Eric A; Loring, Stephen H; Estépar, Raúl San José; Diaz, Alejandro A; Sciurba, Frank C; Silverman, Edwin K; Han, MeiLan K; Decamp, Malcolm; Reilly, John J
2010-03-01
Previous investigations have identified several potential predictors of outcomes from lung volume reduction surgery (LVRS). A concern regarding these studies has been their small sample size, which may limit generalizability. We therefore sought to examine radiographic and physiologic predictors of surgical outcomes in a large, multicenter clinical investigation, the National Emphysema Treatment Trial. To identify objective radiographic and physiological indices of lung disease that have prognostic value in subjects with chronic obstructive pulmonary disease being evaluated for LVRS. A subset of the subjects undergoing LVRS in the National Emphysema Treatment Trial underwent preoperative high-resolution computed tomographic (CT) scanning of the chest and measures of static lung recoil at total lung capacity (SRtlc) and inspiratory resistance (Ri). The relationship between CT measures of emphysema, the ratio of upper to lower zone emphysema, CT measures of airway disease, SRtlc, Ri, the ratio of residual volume to total lung capacity (RV/TLC), and both 6-month postoperative changes in FEV(1) and maximal exercise capacity were assessed. Physiological measures of lung elastic recoil and inspiratory resistance were not correlated with improvement in either the FEV(1) (R = -0.03, P = 0.78 and R = -0.17, P = 0.16, respectively) or maximal exercise capacity (R = -0.02, P = 0.83 and R = 0.08, P = 0.53, respectively). The RV/TLC ratio and CT measures of emphysema and its upper to lower zone ratio were only weakly predictive of postoperative changes in both the FEV(1) (R = 0.11, P = 0.01; R = 0.2, P < 0.0001; and R = 0.23, P < 0.0001, respectively) and maximal exercise capacity (R = 0.17, P = 0.0001; R = 0.15, P = 0.002; and R = 0.15, P = 0.002, respectively). CT assessments of airway disease were not predictive of change in FEV(1) or exercise capacity in this cohort. The RV/TLC ratio and CT measures of emphysema and its distribution are weak but statistically significant predictors of outcome after LVRS.
Jacob, Joseph; Bartholmai, Brian J; Rajagopalan, Srinivasan; Brun, Anne Laure; Egashira, Ryoko; Karwoski, Ronald; Kokosi, Maria; Wells, Athol U; Hansell, David M
2016-11-23
To evaluate computer-based computer tomography (CT) analysis (CALIPER) against visual CT scoring and pulmonary function tests (PFTs) when predicting mortality in patients with connective tissue disease-related interstitial lung disease (CTD-ILD). To identify outcome differences between distinct CTD-ILD groups derived following automated stratification of CALIPER variables. A total of 203 consecutive patients with assorted CTD-ILDs had CT parenchymal patterns evaluated by CALIPER and visual CT scoring: honeycombing, reticular pattern, ground glass opacities, pulmonary vessel volume, emphysema, and traction bronchiectasis. CT scores were evaluated against pulmonary function tests: forced vital capacity, diffusing capacity for carbon monoxide, carbon monoxide transfer coefficient, and composite physiologic index for mortality analysis. Automated stratification of CALIPER-CT variables was evaluated in place of and alongside forced vital capacity and diffusing capacity for carbon monoxide in the ILD gender, age physiology (ILD-GAP) model using receiver operating characteristic curve analysis. Cox regression analyses identified four independent predictors of mortality: patient age (P < 0.0001), smoking history (P = 0.0003), carbon monoxide transfer coefficient (P = 0.003), and pulmonary vessel volume (P < 0.0001). Automated stratification of CALIPER variables identified three morphologically distinct groups which were stronger predictors of mortality than all CT and functional indices. The Stratified-CT model substituted automated stratified groups for functional indices in the ILD-GAP model and maintained model strength (area under curve (AUC) = 0.74, P < 0.0001), ILD-GAP (AUC = 0.72, P < 0.0001). Combining automated stratified groups with the ILD-GAP model (stratified CT-GAP model) strengthened predictions of 1- and 2-year mortality: ILD-GAP (AUC = 0.87 and 0.86, respectively); stratified CT-GAP (AUC = 0.89 and 0.88, respectively). CALIPER-derived pulmonary vessel volume is an independent predictor of mortality across all CTD-ILD patients. Furthermore, automated stratification of CALIPER CT variables represents a novel method of prognostication at least as robust as PFTs in CTD-ILD patients.
Hyodo, Tomoko; Hori, Masatoshi; Lamb, Peter; Sasaki, Kosuke; Wakayama, Tetsuya; Chiba, Yasutaka; Mochizuki, Teruhito; Murakami, Takamichi
2017-02-01
Purpose To assess the ability of fast-kilovolt-peak switching dual-energy computed tomography (CT) by using the multimaterial decomposition (MMD) algorithm to quantify liver fat. Materials and Methods Fifteen syringes that contained various proportions of swine liver obtained from an abattoir, lard in food products, and iron (saccharated ferric oxide) were prepared. Approval of this study by the animal care and use committee was not required. Solid cylindrical phantoms that consisted of a polyurethane epoxy resin 20 and 30 cm in diameter that held the syringes were scanned with dual- and single-energy 64-section multidetector CT. CT attenuation on single-energy CT images (in Hounsfield units) and MMD-derived fat volume fraction (FVF; dual-energy CT FVF) were obtained for each syringe, as were magnetic resonance (MR) spectroscopy measurements by using a 1.5-T imager (fat fraction [FF] of MR spectroscopy). Reference values of FVF (FVF ref ) were determined by using the Soxhlet method. Iron concentrations were determined by inductively coupled plasma optical emission spectroscopy and divided into three ranges (0 mg per 100 g, 48.1-55.9 mg per 100 g, and 92.6-103.0 mg per 100 g). Statistical analysis included Spearman rank correlation and analysis of covariance. Results Both dual-energy CT FVF (ρ = 0.97; P < .001) and CT attenuation on single-energy CT images (ρ = -0.97; P < .001) correlated significantly with FVF ref for phantoms without iron. Phantom size had a significant effect on dual-energy CT FVF after controlling for FVF ref (P < .001). The regression slopes for CT attenuation on single-energy CT images in 20- and 30-cm-diameter phantoms differed significantly (P = .015). In sections with higher iron concentrations, the linear coefficients of dual-energy CT FVF decreased and those of MR spectroscopy FF increased (P < .001). Conclusion Dual-energy CT FVF allows for direct quantification of fat content in units of volume percent. Dual-energy CT FVF was larger in 30-cm than in 20-cm phantoms, though the effect of object size on fat estimation was less than that of CT attenuation on single-energy CT images. In the presence of iron, dual-energy CT FVF led to underestimateion of FVF ref to a lesser degree than FF of MR spectroscopy led to overestimation of FVF ref . © RSNA, 2016 Online supplemental material is available for this article.
Conradie, Wilhelmus Jacobus; Gebremariam, Fekade Admassu
2015-01-01
To determine the sensitivity and specificity of computed tomography (CT) esophagography in diagnosing penetrating esophageal and hypopharyngeal injuries in trauma patients and to see if it can be used as the only imaging method in diagnosing these injuries. The confidence of radiologists using only CT esophagography was also measured. A prospective cross-sectional analytic study was done on haemodinamically stable patients requiring multidetector CT after external penetrating neck or chest trauma. Each patient was given oral contrast consisting of 50 ml 50% iohexol solution, within 5 min of commencement of the CT examination and in the supine position. An attempt was made to confirm all CT esophagography findings with at least one secondary method. Images were evaluated separately by two general departmental radiologists who were blinded to the results of the confirmation method. Between December 2012 and November 2014, 102 patients were included, of which 93 (91.2%) were male. Stab wounds were responsible for 85.3% (n=87) of penetrating wounds. Ninety-four patients (92.2%) had CT angiography (CTA) in conjunction with CT esophagography. There were 20 confirmed upper digestive tract injuries; 11 (55.0%) in the hypopharynx and 9 (45.0%) in the esophagus. With the exception of one case, all upper digestive tract injuries were diagnosed using only CT esophagography. No upper digestive tract injuries were correctly identified in 70 and 75 out of 82 true negative cases respectively, suggesting a sensitivity of 95.0% for both radiologists and specificity of 85.4% and 91.5% for CT esophagography. A number of false positive diagnoses were reported when CT esophagography was done in conjunction with CTA, resulting in a positive predictive value of 61.3% and 79.1% for this technique. Reviewers were positive to very confident about the CT esophagography findings in 90.0% and 100% of patients with injuries and 79.0% and 87.0%, respectively, in the no injury group. CT esophagography is reliable in diagnosing penetrating upper digestive tract injuries. In conjunction with CTA, false positive findings may occur. Radiologists were generally positive to very confident about their CT esophagography findings, not needing further imaging in more than 60% of cases. Copyright © 2015 Elsevier Inc. All rights reserved.
Iguchi, Toshihiro; Hiraki, Takao; Gobara, Hideo; Fujiwara, Hiroyasu; Matsui, Yusuke; Miyoshi, Shinichiro; Kanazawa, Susumu
2016-01-01
To retrospectively evaluate the safety of computed tomography (CT) fluoroscopy-guided short hook wire placement for video-assisted thoracoscopic surgery and the risk factors for pneumothorax associated with this procedure. We analyzed 267 short hook wire placements for 267 pulmonary lesions (mean diameter, 9.9 mm). Multiple variables related to the patients, lesions, and procedures were assessed to determine the risk factors for pneumothorax. Complications (219 grade 1 and 4 grade 2 adverse events) occurred in 196 procedures. No grade 3 or above adverse events were observed. Univariate analysis revealed increased vital capacity (odds ratio [OR], 1.518; P = 0.021), lower lobe lesion (OR, 2.343; P =0.001), solid lesion (OR, 1.845; P = 0.014), prone positioning (OR, 1.793; P = 0.021), transfissural approach (OR, 11.941; P = 0.017), and longer procedure time (OR, 1.036; P = 0.038) were significant predictors of pneumothorax. Multivariate analysis revealed only the transfissural approach (OR, 12.171; P = 0.018) and a longer procedure time (OR, 1.048; P = 0.012) as significant independent predictors. Complications related to CT fluoroscopy-guided preoperative short hook wire placement often occurred, but all complications were minor. A transfissural approach and longer procedure time were significant independent predictors of pneumothorax. Complications related to CT fluoroscopy-guided preoperative short hook wire placement often occur. Complications are usually minor and asymptomatic. A transfissural approach and longer procedure time are significant independent predictors of pneumothorax.
Kivisaari, Riku; Svensson, Mikael; Skrifvars, Markus B.
2017-01-01
Background Traumatic brain injury (TBI) is a major contributor to morbidity and mortality. Computerized tomography (CT) scanning of the brain is essential for diagnostic screening of intracranial injuries in need of neurosurgical intervention, but may also provide information concerning patient prognosis and enable baseline risk stratification in clinical trials. Novel CT scoring systems have been developed to improve current prognostic models, including the Stockholm and Helsinki CT scores, but so far have not been extensively validated. The primary aim of this study was to evaluate the Stockholm and Helsinki CT scores for predicting functional outcome, in comparison with the Rotterdam CT score and Marshall CT classification. The secondary aims were to assess which individual components of the CT scores best predict outcome and what additional prognostic value the CT scoring systems contribute to a clinical prognostic model. Methods and findings TBI patients requiring neuro-intensive care and not included in the initial creation of the Stockholm and Helsinki CT scoring systems were retrospectively included from prospectively collected data at the Karolinska University Hospital (n = 720 from 1 January 2005 to 31 December 2014) and Helsinki University Hospital (n = 395 from 1 January 2013 to 31 December 2014), totaling 1,115 patients. The Marshall CT classification and the Rotterdam, Stockholm, and Helsinki CT scores were assessed using the admission CT scans. Known outcome predictors at admission were acquired (age, pupil responsiveness, admission Glasgow Coma Scale, glucose level, and hemoglobin level) and used in univariate, and multivariable, regression models to predict long-term functional outcome (dichotomizations of the Glasgow Outcome Scale [GOS]). In total, 478 patients (43%) had an unfavorable outcome (GOS 1–3). In the combined cohort, overall prognostic performance was more accurate for the Stockholm CT score (Nagelkerke’s pseudo-R2 range 0.24–0.28) and the Helsinki CT score (0.18–0.22) than for the Rotterdam CT score (0.13–0.15) and Marshall CT classification (0.03–0.05). Moreover, the Stockholm and Helsinki CT scores added the most independent prognostic value in the presence of other known clinical outcome predictors in TBI (6% and 4%, respectively). The aggregate traumatic subarachnoid hemorrhage (tSAH) component of the Stockholm CT score was the strongest predictor of unfavorable outcome. The main limitations were the retrospective nature of the study, missing patient information, and the varying follow-up time between the centers. Conclusions The Stockholm and Helsinki CT scores provide more information on the damage sustained, and give a more accurate outcome prediction, than earlier classification systems. The strong independent predictive value of tSAH may reflect an underrated component of TBI pathophysiology. A change to these newer CT scoring systems may be warranted. PMID:28771476
Shimonobo, Toshiaki; Funama, Yoshinori; Utsunomiya, Daisuke; Nakaura, Takeshi; Oda, Seitaro; Kiguchi, Masao; Masuda, Takanori; Sakabe, Daisuke; Yamashita, Yasuyuki; Awai, Kazuo
2016-01-01
We used pediatric and adult anthropomorphic phantoms to compare the radiation dose of low- and standard tube voltage chest and abdominal non-contrast-enhanced computed tomography (CT) scans. We also discuss the optimal low tube voltage for non-contrast-enhanced CT. Using a female adult- and three differently-sized pediatric anthropomorphic phantoms we acquired chest and abdominal non-contrast-enhanced scans on a 320-multidetector CT volume scanner. The tube voltage was set at 80-, 100-, and 120 kVp. The tube current was automatically assigned on the CT scanner in response to the set image noise level. On each phantom and at each tube voltage we measured the surface and center dose using high-sensitivity metal-oxide-semiconductor field-effect transistor detectors. The mean surface dose of chest and abdominal CT scans in 5-year olds was 4.4 and 5.3 mGy at 80 kVp, 4.5 and 5.4 mGy at 100 kV, and 4.0 and 5.0 mGy at 120 kVp, respectively. These values were similar in our 3-pediatric phantoms (p > 0.05). The mean surface dose in the adult phantom increased from 14.7 to 19.4 mGy for chest- and from 18.7 to 24.8 mGy for abdominal CT as the tube voltage decreased from 120 to 80 kVp (p < 0.01). Compared to adults, the surface and center dose for pediatric patients is almost the same despite a decrease in the tube voltage and the low tube voltage technique can be used for non-contrast-enhanced chest- and abdominal scanning. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Peripheral Quantitative CT (pQCT) Using a Dedicated Extremity Cone-Beam CT Scanner
Muhit, A. A.; Arora, S.; Ogawa, M.; Ding, Y.; Zbijewski, W.; Stayman, J. W.; Thawait, G.; Packard, N.; Senn, R.; Yang, D.; Yorkston, J.; Bingham, C.O.; Means, K.; Carrino, J. A.; Siewerdsen, J. H.
2014-01-01
Purpose We describe the initial assessment of the peripheral quantitative CT (pQCT) imaging capabilities of a cone-beam CT (CBCT) scanner dedicated to musculoskeletal extremity imaging. The aim is to accurately measure and quantify bone and joint morphology using information automatically acquired with each CBCT scan, thereby reducing the need for a separate pQCT exam. Methods A prototype CBCT scanner providing isotropic, sub-millimeter spatial resolution and soft-tissue contrast resolution comparable or superior to standard multi-detector CT (MDCT) has been developed for extremity imaging, including the capability for weight-bearing exams and multi-mode (radiography, fluoroscopy, and volumetric) imaging. Assessment of pQCT performance included measurement of bone mineral density (BMD), morphometric parameters of subchondral bone architecture, and joint space analysis. Measurements employed phantoms, cadavers, and patients from an ongoing pilot study imaged with the CBCT prototype (at various acquisition, calibration, and reconstruction techniques) in comparison to MDCT (using pQCT protocols for analysis of BMD) and micro-CT (for analysis of subchondral morphometry). Results The CBCT extremity scanner yielded BMD measurement within ±2–3% error in both phantom studies and cadaver extremity specimens. Subchondral bone architecture (bone volume fraction, trabecular thickness, degree of anisotropy, and structure model index) exhibited good correlation with gold standard micro-CT (error ~5%), surpassing the conventional limitations of spatial resolution in clinical MDCT scanners. Joint space analysis demonstrated the potential for sensitive 3D joint space mapping beyond that of qualitative radiographic scores in application to non-weight-bearing versus weight-bearing lower extremities and assessment of phalangeal joint space integrity in the upper extremities. Conclusion The CBCT extremity scanner demonstrated promising initial results in accurate pQCT analysis from images acquired with each CBCT scan. Future studies will include improved x-ray scatter correction and image reconstruction techniques to further improve accuracy and to correlate pQCT metrics with known pathology. PMID:25076823
Hori, Masatoshi; Suzuki, Kenji; Epstein, Mark L.; Baron, Richard L.
2011-01-01
The purpose was to evaluate a relationship between slice thickness and calculated volume on CT liver volumetry by comparing the results for images with various slice thicknesses including three-dimensional images. Twenty adult potential liver donors (12 men, 8 women; mean age, 39 years; range, 24–64) underwent CT with a 64-section multi-detector row CT scanner after intra-venous injection of contrast material. Four image sets with slice thicknesses of 0.625 mm, 2.5 mm, 5 mm, and 10 mm were used. First, a program developed in our laboratory for automated liver extraction was applied to CT images, and the liver boundary was obtained automatically. Then, an abdominal radiologist reviewed all images on which automatically extracted boundaries were superimposed, and edited the boundary on each slice to enhance the accuracy. Liver volumes were determined by counting of the voxels within the liver boundary. Mean whole liver volumes estimated with CT were 1322.5 cm3 on 0.625-mm, 1313.3 cm3 on 2.5-mm, 1310.3 cm3 on 5-mm, and 1268.2 cm3 on 10-mm images. Volumes calculated for three-dimensional (0.625-mm-thick) images were significantly larger than those for thicker images (P<.0001). Partial liver volumes of right lobe, left lobe, and lateral segment were also evaluated in a similar manner. Estimated maximum differences in calculated volumes of lateral segment was −10.9 cm3 (−4.6%) between 0.625-mm and 5-mm images. In conclusion, liver volumes calculated on 2.5-mm or thicker images were significantly smaller than volumes calculated on three-dimensional images. If a maximum error of 5% in the calculated graft volume is within the range of having an insignificant clinical impact, 5-mm thick images are acceptable for CT volumetry. If not, three-dimensional images could be essential. PMID:21850689
Utility of cardiac computed tomography for evaluation of pannus in mechanical aortic valve.
Suh, Young Joo; Kim, Young Jin; Lee, Sak; Hong, Yoo Jin; Lee, Hye-Jeong; Hur, Jin; Choi, Byoung Wook; Chang, Byung-Chul
2015-08-01
The clinical significance of pannus detected on computed tomography (CT) has not yet been investigated. The purposes of this study were to investigate the clinical significance of pannus detected on cardiac CT in patients who underwent aortic valve replacement (AVR) with mechanical valves, and to determine predictors for pannus severity. A total of 92 patients who underwent cardiac CT and TTE and who had undergone mechanical AVR were included. The geometric orifice area (GOA), the presence of limitation of motion (LOM) and pannus were evaluated on CT. The GOA, presence of LOM, and presence and severity of pannus were compared with echocardiographic parameters. Logistic regression analysis was performed to determine the predictors for pannus severity. The GOA on CT positively correlated with effective orifice area on TTE (r = 0.733, P < 0.0001). Pannus was found in 77.2% and LOM in 14.0%. With increasing pannus severity, mean transvalvular pressure gradient (PG) was significantly higher (P < 0.0001). Patients with elevated PG showed a smaller GOA, a higher incidence of pannus, more severe pannus and LOM than patients with normal PG (P < 0.05). Small valve size (≤19 mm), Carbomedics valve, rheumatic etiology, and young age at AVR (<48.8 years) were independent predictors of moderate to severe pannus (P < 0.05). Cardiac CT is helpful in the evaluation of pannus formation in patients with mechanical aortic valves. Moderate to severe pannus formation frequently occurred in patients with small mechanical valve size, Carbomedics valves, rheumatic heart disease and young age at AVR.
Corneal Thickness as a Predictor of Corneal Transplant Outcome
Verdier, David D.; Sugar, Alan; Baratz, Keith; Beck, Roy; Dontchev, Mariya; Dunn, Steven; Gal, Robin L.; Holland, Edward J.; Kollman, Craig; Lass, Jonathan H.; Mannis, Mark J.; Penta, Jeffrey
2013-01-01
Purpose Assess corneal thickness (CT) and correlation with graft outcome after penetrating keratoplasty in the Cornea Donor Study. Methods 887 subjects with a corneal transplant for a moderate risk condition (principally Fuchs or pseudophakic corneal edema) had post-operative CT measurements throughout a 5 year follow up time. Relationships between baseline (recipient, donor, and operative) factors and CT were explored. Proportional hazards models were used to assess association between CT and graft failure. Relationship between CT and cell density was assessed with a longitudinal repeated measures model and Spearman correlation estimates. Results Higher longitudinal CT measurements were associated with diagnosis of pseudophakic or aphakic corneal edema (P<0.001), intraocular pressure > 25mmHg during the first post-operative month (P=0.003), white (non-Hispanic) donor race (P=0.002) and respiratory causes of donor death (P<0.001). Among those without graft failure within the first post-operative year, the 5-year cumulative incidence (±95% CI) of graft failure was 5% ± 5% in those with a 1-year CT ≤500μm, 5% ± 3% for CT 501 – 550μm, 7% ± 4% for CT 551 – 600μm and 20% ± 11% for CT >600μm. In multivariate analysis, both 1 year CT and cell density were associated with subsequent graft failure (P=0.002 and 0.009). CT increase was modestly associated with endothelial cell loss during follow up (r=-0.29). Conclusion During the first 5 years following penetrating keratoplasty, CT can serve as a predictor of graft survival. However, CT is not a substitute for cell density measurement as both measures were independently predictive of graft failure. PMID:23343949
Rieger, Michael; Czermak, Benedikt; El Attal, Rene; Sumann, Günther; Jaschke, Werner; Freund, Martin
2009-03-01
The objective of this study was to assess time management and diagnostic quality when using a 64-multidetector-row computed tomography (MDCT) whole-body scanner to evaluate polytraumatized patients in an emergency department. Eighty-eight consecutive polytraumatized patients with injury severity score (ISS) > or = 18 (mean ISS = 29) were included in this study. Documented and evaluated data were crash history, trauma mechanism, number and pattern of injuries, injury severity, diagnostics, time flow, and missed diagnoses. Data were stored in our hospital information system. Seven time intervals were evaluated. In particular, attention was paid to the "acquisition interval," the "reformatting and evaluation time" as well as the "CT time" (time from CT start to preliminary diagnosis). A standardized whole-body CT was performed. The acquired CT data together with automatically generated multiplanar reformatted images ("direct MPR") were transferred to a 3D rendering workstation. Diagnostic quality was determined on the basis of missed diagnoses. Head-to-toe scout images were possible because volume coverage was up to 2 m. Experienced radiologists at an affiliated workstation performed radiologic evaluation of the acquired datasets immediately after acquisition. The "acquisition interval" was 12 minutes +/- 4.9 minutes, the "reformatting and evaluation interval" 7.0 minutes +/- 2.1 minutes, and the "CT time" 19 minutes +/- 6.1 minutes. Altogether, 7 of 486 lesions were recognized but not communicated in the "reformatting and evaluation interval", and 10 injuries were initially missed and detected during follow-up. This study indicates that 64-MDCT saves time, especially in the "reformatting and evaluation interval." Diagnostic quality is high, as reflected by the small number of missed diagnoses.
Imaging in traumatic mandibular fractures
Gemal, Hugo; Reed, Duncan
2017-01-01
A fracture of the mandible is a common trauma presentation amongst young males and represents one of the most frequently encountered fractured bones within the viscerocranium. Historically, assault was the dominant contributing factor but now due to the increased number of vehicles used per capita, motor vehicle accidents are the primary cause. Mandibular fractures can be classified anatomically, by dentition, by muscle group and by severity. The fracture may also be closed, open, comminuted, displaced or pathological. It is important that the imaging modality used identifies the classification as this will decide definitive treatment. X-ray projections have typically been used to detect a mandibular fracture, but are limited to an anteroposterior (AP), lateral and oblique view in an unstable trauma patient. These views are inadequate to detail the level of fracture displacement and show poor detail of the condylar region. Computer tomography (CT) is the imaging modality of choice when assessing a traumatic mandibular injury and can demonstrate a 100% sensitivity in detecting a fracture. This is through use of a multidetector-row CT, which reduces motion blur and therefore produces accurate coronal and sagittal reconstructions. Furthermore, reconstructive three-dimensional CT images gained from planar views, allows a better understanding of the spatial relationship of the fracture with other anatomical landmarks. This ensures a better appreciation of the severity and classification of a mandibular fracture, which therefore influences operative planning. Ultrasound is another useful modality in detecting a mandibular fracture when the patient is too unstable to be transferred to a CT scanner. The sensitivity however is less in comparison to a CT series of images and provides limited detail on the fracture pattern. Magnetic resonance imaging demonstrates use in assessing soft tissue injury of the temporomandibular joint but this is unlikely to be of priority when initially assessing a trauma patient. PMID:28932703
The prevalence of lumbar spondylolysis in young children: a retrospective analysis using CT.
Lemoine, Thibaut; Fournier, Joseph; Odent, Thierry; Sembély-Taveau, Catherine; Merenda, Pauline; Sirinelli, Dominique; Morel, Baptiste
2018-05-01
Although lumbar spondylolysis is encountered in general population with an incidence estimated to be 3-10%, limited information is available for children. The aim of the study is to determine the prevalence of spondylolysis according to associated vertebral bony malformation and spinopelvic parameters in children under eight requiring CT evaluation for unrelated lumbar conditions. Seven hundred and seventeen abdominal and pelvic multi-detector CT scans were obtained in patients under 8 years of age were reviewed. Two board certificated radiologists and two resident radiologists retrospectively evaluated CT scans for lumbar spondylolysis and associated malformations. Pelvic incidence and spondylolisthesis were reported. Our analysis included 717 CT scans in 532 children (259 girls and 273 boys). Twenty-five cases of spondylolysis were diagnosed (16 bilateral and 9 unilateral, 64 and 36%, respectively) in 14 boys (56%) and 11 girls (44%), associating with 12 grade I spondylolisthesis. The mean normal pelvic incidence was 45° (median 44°, SD 7°). The prevalence of spondylolysis was 1% in children under age 3 (n = 3 among 292 patients), 3.7% in children under age 6 (n = 17 among 454 patients) and 4.7% among the 532 patients. Unilateral spondylolysis was significantly associated with a spinal malformation (p = 0.04, Fisher's exact test), with normal pelvic incidence. Half of the patients with bilateral spondylolysis had high pelvic incidence. We observed a prevalence peak of unilateral spondylolysis in the context of a specific malformation in young infants under age 4 with normal pelvic incidence, and, then, a progressive increase in the prevalence of bilateral isolated spondylolysis.
Pediatric chest and abdominopelvic CT: organ dose estimation based on 42 patient models.
Tian, Xiaoyu; Li, Xiang; Segars, W Paul; Paulson, Erik K; Frush, Donald P; Samei, Ehsan
2014-02-01
To estimate organ dose from pediatric chest and abdominopelvic computed tomography (CT) examinations and evaluate the dependency of organ dose coefficients on patient size and CT scanner models. The institutional review board approved this HIPAA-compliant study and did not require informed patient consent. A validated Monte Carlo program was used to perform simulations in 42 pediatric patient models (age range, 0-16 years; weight range, 2-80 kg; 24 boys, 18 girls). Multidetector CT scanners were modeled on those from two commercial manufacturers (LightSpeed VCT, GE Healthcare, Waukesha, Wis; SOMATOM Definition Flash, Siemens Healthcare, Forchheim, Germany). Organ doses were estimated for each patient model for routine chest and abdominopelvic examinations and were normalized by volume CT dose index (CTDI(vol)). The relationships between CTDI(vol)-normalized organ dose coefficients and average patient diameters were evaluated across scanner models. For organs within the image coverage, CTDI(vol)-normalized organ dose coefficients largely showed a strong exponential relationship with the average patient diameter (R(2) > 0.9). The average percentage differences between the two scanner models were generally within 10%. For distributed organs and organs on the periphery of or outside the image coverage, the differences were generally larger (average, 3%-32%) mainly because of the effect of overranging. It is feasible to estimate patient-specific organ dose for a given examination with the knowledge of patient size and the CTDI(vol). These CTDI(vol)-normalized organ dose coefficients enable one to readily estimate patient-specific organ dose for pediatric patients in clinical settings. This dose information, and, as appropriate, attendant risk estimations, can provide more substantive information for the individual patient for both clinical and research applications and can yield more expansive information on dose profiles across patient populations within a practice. © RSNA, 2013.
Uyeda, Jennifer W; LeBedis, Christina A; Penn, David R; Soto, Jorge A; Anderson, Stephan W
2014-01-01
To determine whether the addition of arterial phase computed tomography (CT) to the standard combination of portal venous and delayed phase imaging increases sensitivity in the diagnosis of active hemorrhage and/or contained vascular injuries in patients with splenic trauma. The institutional review board approved this HIPAA-compliant retrospective study; the requirement to obtain informed consent was waived. The study included all patients aged 15 years and older who sustained a splenic injury from blunt or penetrating trauma and who underwent CT in the arterial and portal venous phases of image acquisition during a 74-month period (September 2005 to November 2011). CT scans were reviewed by three radiologists, and a consensus interpretation was made to classify the splenic injuries according to the American Association for the Surgery of Trauma splenic injury scale. One radiologist independently recorded the presence of contained vascular injuries or active hemorrhage and the phase or phases at which these lesions were seen. Clinical outcome was assessed by reviewing medical records. The relationship between imaging findings and clinical management was assessed with the Fisher exact test. One hundred forty-seven patients met the inclusion criteria; 32 patients (22%) had active hemorrhage and 22 (15%) had several contained vascular injuries. In 13 of the 22 patients with contained injuries, the vascular lesion was visualized only at the arterial phase of image acquisition; the other nine contained vascular injuries were seen at all phases. Surgery or embolization was performed in 11 of the 22 patients with contained vascular injury. The arterial phase of image acquisition improves detection of traumatic contained splenic vascular injuries and should be considered to optimize detection of splenic injuries in trauma with CT. ©RSNA, 2013.
Lee, In Sook; Lee, Jung-Hoon; Woo, Chang-Ki; Kim, Hak Jin; Sol, Yu Li; Song, Jong Woon; Cho, Kyu-Sup
2016-02-01
The purpose of this study was to evaluate and compare the diagnostic efficacy of ultrasonography (US) with radiography and multi-detector computed tomography (CT) for the detection of nasal bone fractures. Forty-one patients with a nasal bone fracture who underwent prospective US examinations were included. Plain radiographs and CT images were obtained on the day of trauma. For US examinations, radiologist used a linear array transducer (L17-5 MHz) in 24 patients and hockey-stick probe (L15-7 MHz) in 17. The bony component of the nose was divided into three parts (right and left lateral nasal walls, and midline of nasal bone). Fracture detection by three modalities was subjected to analysis. Furthermore, findings made by each modality were compared with intraoperative findings. Nasal bone fractures were located in the right lateral wall (n = 28), midline of nasal bone (n = 31), or left lateral wall (n = 31). For right and left lateral nasal walls, CT had greater sensitivity and specificity than US or radiography, and better agreed with intraoperative findings. However, for midline fractures of nasal bone, US had higher specificity, positive predictive value, and negative predictive value than CT. Although two US evaluations showed good agreements at all three sites, US findings obtained by the hockey-stick probe showed closer agreement with intraoperative findings for both lateral nasal wall and midline of nasal bone. Although CT showed higher sensitivity and specificity than US or radiography, US found to be helpful for evaluating the midline of nasal bone. Furthermore, for US examinations of the nasal bone, a smaller probe and higher frequency may be required.
NASA Astrophysics Data System (ADS)
Kang, Y. M.; Cho, J. H.; Kim, S. C.
2015-07-01
This study examined the effects of entrance surface dose (ESD) on the abdomen and pelvis of the patient when undergoing chest computed tomography (CT) procedure, and evaluated the effects of ESD reduction depending on the location of radiation shield. For CT scanner, the 64-slice multi-detector computed tomography was used. The alderson radiation therapy phantom and optically stimulated luminescence dosimeter (OSLD), which enabled measurement from low to high dose, were also used. For measurement of radiation dose, the slice number from 9 to 21 of the phantom was set as the test range, which included apex up to both costophrenic angles. A total of 10 OSLD nanoDots were attached for measurement of the front and rear ESD. Cyclic tests were performed using the low-dose chest CT and high-resolution CT (HRCT) protocol on the following set-ups: without shielding; shielding only on the front side; shielding only on the rear side; and shielding for both front and rear sides. According to the test results, ESD for both front and rear sides was higher in HRCT than low-dose CT when radiation shielding was not used. It was also determined that, compared to the set-up that did not use the radiation shield, locating the radiation shield on the front side was effective in reducing front ESD, while locating the radiation shield on the rear side reduced rear ESD level. Shielding both the front and rear sides resulted in ESD reduction. In conclusion, it was confirmed that shielding the front and rear sides was the most effective method to reduce the ESD effect caused by scatter ray during radiography.
Lee, E J; Lee, S K; Agid, R; Howard, P; Bae, J M; terBrugge, K
2009-10-01
The combined automatic tube current modulation (ATCM) technique adapts and modulates the x-ray tube current in the x-y-z axis according to the patient's individual anatomy. We compared image quality and radiation dose of the combined ATCM technique with those of a fixed tube current (FTC) technique in craniocervical CT angiography performed with a 64-section multidetector row CT (MDCT) system. A retrospective review of craniocervical CT angiograms (CTAs) by using combined ATCM (n = 25) and FTC techniques (n = 25) was performed. Other CTA parameters, such as kilovolt (peak), matrix size, FOV, section thickness, pitch, contrast agent, and contrast injection techniques, were held constant. We recorded objective image noise in the muscles at 2 anatomic levels: radiation exposure doses (CT dose index volume and dose-length product); and subjective image quality parameters, such as vascular delineation of various arterial vessels, visibility of small arterial detail, image artifacts, and certainty of diagnosis. The Mann-Whitney U test was used for statistical analysis. No significant difference was detected in subjective image quality parameters between the FTC and combined ATCM techniques. Most subjects in both study groups (49/50, 98%) had acceptable subjective artifacts. The objective image noise values at shoulder level did not show a significant difference, but the noise value at the upper neck was higher with the combined ATCM (P < .05) technique. Significant reduction in radiation dose (18% reduction) was noted with the combined ATCM technique (P < .05). The combined ATCM technique for craniocervical CTA performed at 64-section MDCT substantially reduced radiation exposure dose but maintained diagnostic image quality.
Ohno, Yoshiharu; Seki, Shinichiro; Koyama, Hisanobu; Yoshikawa, Takeshi; Matsumoto, Sumiaki; Takenaka, Daisuke; Kassai, Yoshimori; Yui, Masao; Sugimura, Kazuro
2015-08-01
To compare predictive capabilities of non-contrast-enhanced (CE)- and dynamic CE-perfusion MRIs, thin-section multidetector computed tomography (CT) (MDCT), and perfusion scan for postoperative lung function in non-small cell lung cancer (NSCLC) patients. Sixty consecutive pathologically diagnosed NSCLC patients were included and prospectively underwent thin-section MDCT, non-CE-, and dynamic CE-perfusion MRIs and perfusion scan, and had their pre- and postoperative forced expiratory volume in one second (FEV1 ) measured. Postoperative percent FEV1 (po%FEV1 ) was then predicted from the fractional lung volume determined on semiquantitatively assessed non-CE- and dynamic CE-perfusion MRIs, from the functional lung volumes determined on quantitative CT, from the number of segments observed on qualitative CT, and from uptakes detected on perfusion scans within total and resected lungs. Predicted po%FEV1 s were then correlated with actual po%FEV1 s, which were %FEV1 s measured postoperatively. The limits of agreement were also determined. All predicted po%FEV1 s showed significant correlation (0.73 ≤ r ≤ 0.93, P < 0.0001) and limits of agreement with actual po%FEV1 (non-CE-perfusion MRI: 0.3 ± 10.0%, dynamic CE-perfusion MRI: 1.0 ± 10.8%, perfusion scan: 2.2 ± 14.1%, quantitative CT: 1.2 ± 9.0%, qualitative CT: 1.5 ± 10.2%). Non-CE-perfusion MRI may be able to predict postoperative lung function more accurately than qualitatively assessed MDCT and perfusion scan. © 2014 Wiley Periodicals, Inc.
Impact of bronchiectasis and trapped air on quality of life and exacerbations in cystic fibrosis.
Tepper, Leonie A; Utens, Elisabeth M W J; Caudri, Daan; Bos, Aukje C; Gonzalez-Graniel, Karla; Duivenvoorden, Hugo J; van der Wiel, Els C W; Quittner, Alexandra L; Tiddens, Harm A W M
2013-08-01
Cystic fibrosis (CF) is primarily characterised by bronchiectasis and trapped air on chest computed tomography (CT). The revised Cystic Fibrosis Questionnaire respiratory symptoms scale (CFQ-R RSS) measures health-related quality of life. To validate bronchiectasis, trapped air and CFQ-R RSS as outcome measures, we investigated correlations and predictive values for pulmonary exacerbations. CF patients (aged 6-20 years) underwent CT, CFQ-R RSS and 1-year follow-up. Bronchiectasis and trapped air were scored using the CF-CT scoring system. Correlation coefficients and backward multivariate modelling were used to identify predictors of pulmonary exacerbations. 40 children and 32 adolescents were included. CF-CT bronchiectasis (r = -0.38, p<0.001) and CF-CT trapped air (r = -0.35, p = 0.003) correlated with CFQ-R RSS. Pulmonary exacerbations were associated with: bronchiectasis (rate ratio 1.10, 95% CI 1.02-1.19; p = 0.009), trapped air (rate ratio 1.02, 95% CI 1.00-1.05; p = 0.034) and CFQ-R RSS (rate ratio 0.95, 95% CI 0.91-0.98; p = 0.002). The CFQ-R RSS was an independent predictor of pulmonary exacerbations (rate ratio 0.96, 95% CI 0.94-0.97; p<0.001). Bronchiectasis, trapped air and CFQ-R RSS were associated with pulmonary exacerbations. The CFQ-R RSS was an independent predictor. This study further validated bronchiectasis, trapped air and CFQ-R RSS as outcome measures in CF.
SHEDD-WISE, KRISTINE M.; ALEKEL, D. LEE; HOFMANN, HEIKE; HANSON, KATHY B.; SCHIFERL, DAN J.; HANSON, LAURA N.; VAN LOAN, MARTA D.
2011-01-01
Soy isoflavones exert inconsistent bone density-preserving effects, but the bone strength-preserving effects in humans are unknown. Our double-blind randomized controlled trial examined two soy isoflavone doses (80 or 120 mg/d) vs placebo tablets on volumetric bone mineral density (vBMD) and strength (via peripheral quantitative computed tomography) in healthy postmenopausal women (46–63 y). We measured 3 y change in cortical (Ct) BMD, cortical thickness (CtThk), periosteal circumference (PC), endosteal circumference (EC), and strength-strain index (SSI) at 1/3 midshaft femur (N=171) and trabecular (Tb) BMD, PC, and SSI at 4% distal tibia (N=162). We found no treatment effect on femur CtThk, PC, or EC, or tibia TbBMD or PC. Strongest predictors (negative) of tibia TbBMD and SSI and femur CtBMD were timepoint and bone resorption; whole body fat mass was protective of SSI. As time since last menstrual period (TLMP) increased (p=0.012), 120 mg/d was protective of CtBMD. Strongest predictors of femur SSI were timepoint, bone resorption, and TLMP (protective). Isoflavone tablets were negative predictors of SSI, but 80 mg/d became protective as bone turnover increased (p=0.011). Soy isoflavone treatment for 3 y was modestly beneficial for midshaft femur vBMD as TLMP increased, and for midshaft femur SSI as bone turnover increased. PMID:21295742
Newly graduated nurses' perception of competence and possible predictors: a cross-sectional survey.
Wangensteen, Sigrid; Johansson, Inger S; Björkström, Monica E; Nordström, Gun
2012-01-01
The aim of this study was to describe newly graduated nurses' own perception of competence and to identify possible predictors influencing their perceptions. The target population included nurses who graduated from nursing colleges in June 2006. Data collection was carried out from October 2006 until April 2007 using the Nurse Competence Scale (NCS), the California Critical Thinking Disposition Inventory, and the Research Utilization Questionnaire. The response rate was 33% (n = 620). Pearson's chi-square test, Student t test, and regression analyses were used for statistical calculations. The respondents assessed their overall competence level as "good" and assessed themselves most competent in providing ethical and individualized nursing care. They assessed themselves least competent in evaluating outcomes and further development of patient care. Their use of competence explained between 40% (helping) and 10% (managing) of the variance within the NCS competence categories. Critical thinking (CT) was the most prominent predictor for perception of competence in all competence categories and the overall competence, alone explaining between 20% (NCS total score) and 9% (managing) of the variance. The finding that CT was a significant predictor for perception of competence may indicate that developing nursing students' CT abilities is valuable to increase newly graduated nurses' perception of competence. Copyright © 2012 Elsevier Inc. All rights reserved.
The Preoperative CT-Scan Can Help to Predict Postoperative Complications after Pancreatoduodenectomy
Schröder, Femke F.; de Graaff, Feike; Bouman, Donald E.; Brusse-Keizer, Marjolein; Slump, Kees H.; Klaase, Joost M.
2015-01-01
After pancreatoduodenectomy, complication rates are up to 40%. To predict the risk of developing postoperative pancreatic fistula or severe complications, various factors were evaluated. 110 consecutive patients undergoing pancreatoduodenectomy at our institute between January 2012 and September 2014 with complete CT scan were retrospectively identified. Pre-, per-, and postoperative patients and pathological information were gathered. The CT-scans were analysed for the diameter of the pancreatic duct, attenuation of the pancreas, and the visceral fat area. All data was statistically analysed for predicting POPF and severe complications by univariate and multivariate logistic regression analyses. The POPF rate was 18%. The VFA measured at umbilicus (OR 1.01; 95% CI = 1.00–1.02; P = 0.011) was an independent predictor for POPF. The severe complications rate was 33%. Independent predictors were BMI (OR 1.24; 95% CI = 1.10–1.42; P = 0.001), ASA class III (OR 17.10; 95% CI = 1.60–182.88; P = 0.019), and mean HU (OR 0.98; 95% CI = 0.96–1.00; P = 0.024). In conclusion, VFA measured at the umbilicus seems to be the best predictor for POPF. BMI, ASA III, and the mean HU of the pancreatic body are independent predictors for severe complications following PD. PMID:26605340
Broad ligament hernia successfully repaired by single-incision laparoscopy: A case report.
Takeyama, Hiroshi; Kogita, Yuya; Nishigaki, Takahiko; Yamashita, Masafumi; Aikawa, Eriko; Hoshi, Minako; Taniguchi, Hirokazu; Maruyama, Yasuki; Nakajima, Kazuhiro; Yamamoto, Yoshimitsu; Adachi, Kazushige; Yamamoto, Hitoshi; Ikeda, Kimimasa; Kurokawa, Eiji
2017-11-08
A 52-year-old woman with a history of two parturitions presented with lower abdominal pain. Multi-detector CT of the abdomen showed discontinuity of the sigmoid colon near the broad ligament on the left side. We assigned a provisional diagnosis of an internal hernia progressing through a defect in the broad ligament. SILS revealed a total broad ligament defect on the left side but no signs of ischemic, necrotic bowel. We successfully repaired the broad ligament defect with suturing. At the 2-month follow-up, the patient remained well with no signs of recurrence. This case appears to be the first report of a broad ligament hernia successfully diagnosed and repaired by SILS. © 2017 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.
Takahashi, Fumiaki; Sato, Kaoru; Endo, Akira; Ono, Koji; Ban, Nobuhiko; Hasegawa, Takayuki; Katsunuma, Yasushi; Yoshitake, Takayasu; Kai, Michiaki
2015-08-01
A dosimetry system for computed tomography (CT) examinations, named WAZA-ARI, is being developed to accurately assess radiation doses to patients in Japan. For dose calculations in WAZA-ARI, organ doses were numerically analyzed using average adult Japanese male (JM) and female (JF) phantoms with the Particle and Heavy Ion Transport code System (PHITS). Experimental studies clarified the photon energy distribution of emitted photons and dose profiles on the table for some multi-detector row CT (MDCT) devices. Numerical analyses using a source model in PHITS could specifically take into account emissions of x rays from the tube to the table with attenuation of photons through a beam-shaping filter for each MDCT device based on the experiment results. The source model was validated by measuring the CT dose index (CTDI). Numerical analyses with PHITS revealed a concordance of organ doses with body sizes of the JM and JF phantoms. The organ doses in the JM phantoms were compared with data obtained using previously developed systems. In addition, the dose calculations in WAZA-ARI were verified with previously reported results by realistic NUBAS phantoms and radiation dose measurement using a physical Japanese model (THRA1 phantom). The results imply that numerical analyses using the Japanese phantoms and specified source models can give reasonable estimates of dose for MDCT devices for typical Japanese adults.
Effects of dose reduction on bone strength prediction using finite element analysis
NASA Astrophysics Data System (ADS)
Anitha, D.; Subburaj, Karupppasamy; Mei, Kai; Kopp, Felix K.; Foehr, Peter; Noel, Peter B.; Kirschke, Jan S.; Baum, Thomas
2016-12-01
This study aimed to evaluate the effect of dose reduction, by means of tube exposure reduction, on bone strength prediction from finite-element (FE) analysis. Fresh thoracic mid-vertebrae specimens (n = 11) were imaged, using multi-detector computed tomography (MDCT), at different intensities of X-ray tube exposures (80, 150, 220 and 500 mAs). Bone mineral density (BMD) was estimated from the mid-slice of each specimen from MDCT images. Differences in image quality and geometry of each specimen were measured. FE analysis was performed on all specimens to predict fracture load. Paired t-tests were used to compare the results obtained, using the highest CT dose (500 mAs) as reference. Dose reduction had no significant impact on FE-predicted fracture loads, with significant correlations obtained with reference to 500 mAs, for 80 mAs (R2 = 0.997, p < 0.001), 150 mAs (R2 = 0.998, p < 0.001) and 220 mAs (R2 = 0.987, p < 0.001). There were no significant differences in volume quantification between the different doses examined. CT imaging radiation dose could be reduced substantially to 64% with no impact on strength estimates obtained from FE analysis. Reduced CT dose will enable early diagnosis and advanced monitoring of osteoporosis and associated fracture risk.
Pandolfo, Ignazio; Vinci, Sergio; Salamone, Ignazio; Granata, Francesca; Mazziotti, Silvio
2007-06-01
Our purpose is to codify the anterior ethmoidal artery (AEA) course and its relationship with adjacent structures. Twenty patients with cerebrovascular disease underwent selective internal carotid dual volume angiography. Fusion of the vascular and bony images was obtained successively on a second console. MDCT of the cranium was performed in all patients. To identify the AEA course, multiplanar CT reformations were obtained. In all cases the entry-point of AEA and its course were identified by means of dual volume angiography. The information was confirmed by MDCT. In a second phase, we studied another 78 patients affected by inflammatory disease and polyposis only by means of MDCT, in order to confirm the previous data obtained by comparison between angiography and MDCT. In this second phase, 110/156 vessels were indirectly detected by means of visualization of the ethmoidal entry point. In the remaining cases, AEA was directly shown due to integrity of the thin ethmoidal bone lamellae or bony canal. Dual volume angiography is essential to identify the course of the AEA (standard of reference for the interpretation of CT). In patients with benign rhinosinusal pathology, where invasivity techniques are not justified, MPR reconstructions were of pivotal importance in the evaluation of the course of the artery with particular reference to its relationship with the frontal recess.
Margari, Sergio; Garozzo Velloni, Fernanda; Tonolini, Massimo; Colombo, Ettore; Artioli, Diana; Allievi, Niccolò Ettore; Sammartano, Fabrizio; Chiara, Osvaldo; Vanzulli, Angelo
2018-05-12
To determine the relationship between multidetector computed tomography (MDCT) findings, management strategies, and ultimate clinical outcomes in patients with splenic injuries secondary to blunt trauma. This Institutional Review Board-approved study collected 351 consecutive patients admitted at the Emergency Department (ED) of a Level I Trauma Center with blunt splenic trauma between October 2002 and November 2015. Their MDCT studies were retrospectively and independently reviewed by two radiologists to grade splenic injuries according to the American Association for the Surgery of Trauma (AAST) organ injury scale (OIS) and to detect intraparenchymal (type A) or extraparenchymal (type B) active bleeding and/or contained vascular injuries (CVI). Clinical data, information on management, and outcome were retrieved from the hospital database. Statistical analysis relied on Student's t, chi-squared, and Cohen's kappa tests. Emergency multiphase MDCT was obtained in 263 hemodynamically stable patients. Interobserver agreement for both AAST grading of injuries and vascular lesions was excellent (k = 0.77). Operative management (OM) was performed in 160 patients (45.58% of the whole cohort), and high-grade (IV and V) OIS injuries and type B bleeding were statistically significant (p < 0.05) predictors of OM. Nonoperative management (NOM) failed in 23 patients out of 191 (12.04%). In 75% of them, NOM failure occurred within 30 h from the trauma event, without significant increase of mortality. Both intraparenchymal and extraparenchymal active bleeding were predictive of NOM failure (p < 0.05). Providing detection and characterization of parenchymal and vascular traumatic lesions, MDCT plays a crucial role for safe and appropriate guidance of ED management of splenic traumas and contributes to the shift toward NOM in hemodynamically stable patients.
Jun, Ji Eun; Lee, You-Bin; Lee, Seung-Eun; Ahn, Ji Yeon; Kim, Gyuri; Jin, Sang-Man; Hur, Kyu Yeon; Lee, Moon-Kyu; Kang, Mi Ra; Kim, Jae Hyeon
2018-05-01
Hyperuricemia was frequently noted in subjects with a high risk of cardiovascular disease (CVD). This study aimed to elucidate whether serum uric acid (SUA) is associated with development of moderate coronary artery calcification in generally healthy adults. A total of 9297 subjects underwent multidetector CT for the evaluation of CAC at least two times during their annual health examinations. Among them, 4461 participants without CVD history and who had no (scores 0) or minimal CAC (scores 1-10) in their first examination were enrolled. The association between SUA as a continuous and categorical variable and development of moderate coronary artery calcification (CAC score > 100) was assessed by Cox regression analysis. Receiver-operating characteristic (ROC) curves were constructed to investigate the diagnostic efficacy of SUA. During a median follow-up of 4.1 years, 131 incident cases of moderate calcification developed. Baseline SUA concentration was significantly higher in subjects with progression to moderate coronary artery calcification (6.6 ± 1.3 vs. 5.8 ± 1.3 mg/dL, p < 0.001). SUA as a continuous variable (per 1 mg/dL) and divided into quartiles was positively associated with a higher risk of development of moderate calcification after adjustment for conventional CVD risk factors. The addition of SUA to the conventional CVD risk factors improved the predictive power for development of moderate coronary artery calcification. SUA was an independent predictor for development of moderate coronary artery calcification in subjects with no or minimal calcification. Copyright © 2018 Elsevier B.V. All rights reserved.
Atar, Eli; Kornowski, Ran; Fuchs, Shmuell; Naftali, Noa; Belenky, Alexander; Bachar, Gil N
2007-10-01
Myocardial bridging is a congenital condition in which a segment of an epicardial artery has an intramural course within the myocardium. The aim of the present study was to evaluate the prevalence of myocardial bridging and the ability of 64-slice coronary computed tomography angiography to identify myocardial bridging in asymptomatic adults. One hundred sixty-nine consecutive asymptomatic subjects underwent 64-row multidetector computed tomography (MDCT) of the coronary arteries. Two experienced CT radiologists identified myocardial bridging >1 mm in thickness, by consensus. We examined the frequency of myocardial bridging and evaluated the length, thickness, and coronary wall lesions. Myocardial bridges were found in 28 (17%) of 165 subjects. Twenty-one subjects (75%) had 1 bridge and 7 subjects (25%) had 2, for a total of 35 myocardial bridges. Twenty-one bridges (60%) were located in the left anterior descending, 8.5% in the diagonal branch, and 2.8% in the circumflex arteries. The segment beneath the myocardial bridge was always free of coronary wall plaques, but the arterial segment proximal to it had significant coronary wall plaques in 24 cases (68.6%). We found that the incidence of myocardial bridging in asymptomatic adults is 7%, which is in agreement with some pathologic studies in the literature. Our study shows that MDCT of the coronary arteries is a reliable and noninvasive technique, which can accurately locate the site of myocardial bridging, and measure its thickness, course, and length.
Yahaba, Misuzu; Kawata, Naoko; Iesato, Ken; Matsuura, Yukiko; Sugiura, Toshihiko; Kasai, Hajime; Sakurai, Yoriko; Terada, Jiro; Sakao, Seiichiro; Tada, Yuji; Tanabe, Nobuhiro; Tatsumi, Koichiro
2014-06-01
Chronic obstructive pulmonary disease (COPD) is characterized by airflow limitation caused by emphysema and small airway narrowing. Quantitative evaluation of airway dimensions by multi-detector computed tomography (MDCT) has revealed a correlation between airway dimension and airflow limitation. However, the effect of emphysema on this correlation is unclear. The goal of this study was to determine whether emphysematous changes alter the relationships between airflow limitation and airway dimensions as measured by inspiratory and expiratory MDCT. Ninety-one subjects underwent inspiratory and expiratory MDCT. Images were evaluated for mean airway luminal area (Ai), wall area percentage (WA%) from the third to the fifth generation of three bronchi (B1, B5, B8) in the right lung, and low attenuation volume percent (LAV%). Correlations between each airway index and airflow limitation were determined for each patient and compared between patients with and without evidence of emphysema. In patients without emphysema, Ai and WA% from both the inspiratory and expiratory scans were significantly correlated with FEV1. No correlation was detected in patients with emphysema. In addition, emphysematous COPD patients with GOLD stage 1 or 2 disease had significantly lower changes in B8 Ai than non-emphysematous patients. A significant correlation exists between airway parameters and FEV1 in patients without emphysema. Emphysema may influence airway dimensions even in patients with mild to moderate COPD. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
He, Xiaoning; Holtorf, Anke-Peggy; Rinde, Harald; Xie, Shuangshuang; Shen, Wen; Hou, Jiancun; Li, Xuehua; Li, Ziping; Lai, Jiaming; Wang, Yuting; Zhang, Lin; Wang, Jian; Li, Xuesong; Ma, Kuansheng; Ye, Feng; Ouyang, Han; Zhao, Hong
2018-01-01
Limited data exists in China on the comparative cost of gadolinium ethoxybenzyl diethylenetriamine magnetic resonance imaging (Gd-EOB-DTPA-MRI) with other imaging techniques. This study compared the total cost of Gd-EOB-DTPA-MRI with multidetector computed tomography (MDCT) and extracellular contrast media–enhanced MRI (ECCM-MRI) as initial imaging procedures in patients with suspected hepatocellular carcinoma (HCC). We developed a decision-tree model on the basis of the Chinese clinical guidelines for HCC, which was validated by clinical experts from China. The model compared the diagnostic accuracy and costs of alternative initial imaging procedures. Compared with MDCT and ECCM-MRI, Gd-EOB-DTPA-MRI imaging was associated with higher rates of diagnostic accuracy, i.e. higher proportions of true positives (TP) and true negatives (TN) with lower false positives (FP). Total diagnosis and treatment cost per patient after the initial Gd-EOB-DTPA-MRI evaluation was similar to MDCT (¥30,360 vs. ¥30,803) and lower than that reported with ECCM-MRI (¥30,360 vs. ¥31,465). Lower treatment cost after initial Gd-EOB-DTPA-MRI was driven by reduced utilization of confirmatory diagnostic procedures and unnecessary treatments. The findings reported that Gd-EOB-DTPA-MRI offered higher diagnostic accuracy compared with MDCT and ECCM-MRI at a comparable cost, which indicates Gd-EOB-DTPA-MRI could be the preferred initial imaging procedure for the diagnosis of HCC in China. PMID:29324837
Kim, Jong Gyu
2012-01-01
Background During the planning of a thoracodorsal artery perforator (TDAP) free flap, preoperative multidetector-row computed tomographic (MDCT) angiography is valuable for predicting the locations of perforators. However, CT-based perforator mapping of the thoracodorsal artery is not easy because of its small diameter. Thus, we evaluated 1-mm-thick MDCT images in multiple planes to search for reliable perforators accurately. Methods Between July 2010 and October 2011, 19 consecutive patients (13 males, 6 females) who underwent MDCT prior to TDAP free flap operations were enrolled in this study. Patients ranged in age from 10 to 75 years (mean, 39.3 years). MDCT images were acquired at a thickness of 1 mm in the axial, coronal, and sagittal planes. Results The thoracodorsal artery perforators were detected in all 19 cases. The reliable perforators originating from the descending branch were found in 14 cases, of which 6 had transverse branches. The former were well identified in the coronal view, and the latter in the axial view. The location of the most reliable perforators on MDCT images corresponded well with the surgical findings. Conclusions Though MDCT has been widely used in performing the abdominal perforator free flap for detecting reliable perforating vessels, it is not popular in the TDAP free flap. The results of this study suggest that multiple planes of MDCT may increase the probability of detecting the most reliable perforators, along with decreasing the probability of missing available vessels. PMID:22872839
18F-FDG PET/CT in the detection of asymptomatic malignant melanoma recurrence.
Lawal, Ismaheel; Lengana, Thabo; Ololade, Kehinde; Boshomane, Tebatso; Reyneke, Florette; Modiselle, Moshe; Vorster, Mariza; Sathekge, Mike
2017-06-12
To evaluate the diagnostic accuracy of FDG PET/CT in the detection of asymptomatic recurrence in patients with malignant melanoma who have had resection of their primary lesion. We also aimed to determine the pattern and factors predisposing to disease recurrence. Patients with malignant melanoma who have had surgical resection of their disease and without any clinical evidence of disease recurrence were followed-up with FDG PET/CT. The diagnostic accuracy of FDG PET/CT, pattern of recurrence and factors predictive of disease recurrence were determined. A total of 144 patients were followed-up for a median period of 50.50 months. Asymptomatic recurrence was seen in 37 patients (25.7 %) with a median time to recurrence of 20 months. Lymph node was the commonest site of asymptomatic recurrence. Sex, tumour depth, histology type and presence of nodal metastasis were significant predictors of tumour recurrence. Age, race, site of primary lesion, type of lymph node resection were not significant predictors of disease recurrence. Race has a significant effect on the histological subtype of tumour (nodular maligna was more common in Caucasian while acral lentiginous was more prevalent in the Blacks) and the site of the primary lesion (lower limb in Blacks and trunk in Caucasians). Sensitivity, specificity and accuracy of FDG PET/CT for the detection of disease recurrence were 94.5 %, 87.6 % and 89.6 % respectively. FDG PET/CT is a suitable modality for early detection of asymptomatic recurrence of malignant melanoma. Asymptomatic recurrence most commonly occurs in lymph nodes. Sex, nodal metastasis and tumour pathologic features are predictors of recurrence.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang Xiaodong, E-mail: wangxde@gmail.com; Erinjeri, Joseph P., E-mail: erinjerj@mskcc.org; Jia Xiaoyu, E-mail: jiax@mskcc.org
2013-08-01
PurposeTo determine if the pattern of retained contrast on immediate postprocedure computed tomography (CT) after particle embolization of hepatic tumors predicts modified Response Evaluation Criteria in Solid Tumors (mRECIST) response.Materials and MethodsThis study was approved by the Institutional Review Board with a waiver of authorization. One hundred four liver tumors were embolized with spherical embolic agents (Embospheres, Bead Block, LC Bead) and polyvinyl alcohol. Noncontrast CT was performed immediately after embolization to assess contrast retention in the targeted tumors, and treatment response was assessed by mRECIST criteria on follow-up CT (average time 9.0 {+-} 7.7 weeks after embolization). Tumor contrastmore » retention (TCR) was determined based on change in Hounsfield units (HUs) of the index tumors between the preprocedure and immediate postprocedure scans; vascular contrast retention (VCR) was rated; and defects in contrast retention (DCR) were also documented. The morphology of residual enhancing tumor on follow-up CT was described as partial, circumferential, or total. Association between TCR variables and tumor response were assessed using multivariate logistic regression.ResultsOf 104 hepatic tumors, 51 (49 %) tumors had complete response (CR) by mRECIST criteria; 23 (22.1 %) had partial response (PR); 21 (20.2 %) had stable disease (SD); and 9 (8.7 %) had progressive disease (PD). By multivariate analysis, TCR, VCR, and tumor size are independent predictors of CR (p = 0.02, 0.05, and 0.005 respectively). In 75 tumors, DCR was found to be an independent predictor of failure to achieve complete response (p < 0.0001) by imaging criteria.ConclusionTCR, VCR, and DCR on immediate posttreatment CT are independent predictors of CR by mRECIST criteria.« less
Xie, Yuanliang; Jin, Chaolin; Zhang, Shutong; Wang, Xiang; Jiang, Yanping
2015-01-01
Objective: To study the manifestations of arc of Riolan expansion (ARE) using multi-detector computed tomography angiography (MDCTA). Materials and methods: The manifestations and clinical data of 626 consecutive mesentery CTA images were retrospectively analyzed. The 47 cases with ARE and 47 patients without expansion were involved. The average diameter of arc of Riolan was measured. Two radiologists after reaching consensus analyzed the shapes of mesenteric artery, CT findings and the occurrence and causes of ARE. Results: The mean diameter of arc of Riolan was 1.2 mm, 4.6 mm, 2.5 mm, 2.3 mm, 1.9 mm, 2.5 mm, and 2.0 mm at baseline and following obstruction of superior mesenteric artery (SMA), stenosis of SMA, obstruction of inferior mesenteric artery (IMA), stenosis of IMA, colon cancer, and active ulcerative colitis, respectively. The expansion of arc of Riolan was the most significant following obstruction of SMA. The diameters of arc of Riolan were significantly different between the upward flow group and the downward or the two-way flow groups, and between the colon tumor group and the active ulcerative colitis group. CT findings such as bowel wall thickening, contrast enhancement, intestinal obstruction, marginal artery expansion, lymph node enlargement varied and were help to identify the cause of ARE. Conclusions: ARE often suggests the occurrence of obstructed intestinal feeding artery or intestinal lesions. MDCTA can clearly display the situation of arc of Riolan and collateral circulation, and together with CT symptoms, can guide the selection of diagnosis and treatment schemes in clinic. PMID:26064208
Bertolini, Giovanna; Diana, Alessia; Cipone, Mario; Drigo, Michele; Caldin, Marco
2014-01-01
Caudal vena cava duplication has been rarely reported in small animals. The purpose of this retrospective study was to describe characteristics of duplicated caudal vena cava in a large group of dogs. Computed tomography (CT) and ultrasound databases from two hospitals were searched for canine reports having the diagnosis "double caudal vena cava." One observer reviewed CT images for 71 dogs and two observers reviewed ultrasound images for 21 dogs. In all CT cases, the duplication comprised two vessels that were bilaterally symmetrical and approximately the same calibre (similar to Type I complete duplication in humans). In all ultrasound cases, the duplicated caudal vena cava appeared as a distinct vessel running on the left side of the abdominal segment of the descending aorta and extending from the left common iliac vein to the left renal vein. The prevalence of caudal vena cava duplication was 0.46% for canine ultrasound studies and 2.08% for canine CT studies performed at these hospitals. Median body weight for affected dogs was significantly lower than that of unaffected dogs (P < 0.0001). Breeds with increased risk for duplicated caudal vena cava were Yorkshire Terrier (odds ratio [OR] = 6.41), Poodle (OR = 7.46), West Highland White Terrier (OR = 6.33), and Maltese (OR = 3.87). Presence of a duplicated caudal vena cava was significantly associated with presence of extrahepatic portosystemic shunt(s) (P < 0.004). While uncommon in dogs, caudal vena cava duplication should be differentiated from other vascular anomalies when planning surgeries and for avoiding misdiagnoses. © 2014 American College of Veterinary Radiology.
Jahani, Nariman; Choi, Jiwoong; Iyer, Krishna; Hoffman, Eric A.
2015-01-01
This study aims to assess regional ventilation, nonlinearity, and hysteresis of human lungs during dynamic breathing via image registration of four-dimensional computed tomography (4D-CT) scans. Six healthy adult humans were studied by spiral multidetector-row CT during controlled tidal breathing as well as during total lung capacity and functional residual capacity breath holds. Static images were utilized to contrast static vs. dynamic (deep vs. tidal) breathing. A rolling-seal piston system was employed to maintain consistent tidal breathing during 4D-CT spiral image acquisition, providing required between-breath consistency for physiologically meaningful reconstructed respiratory motion. Registration-derived variables including local air volume and anisotropic deformation index (ADI, an indicator of preferential deformation in response to local force) were employed to assess regional ventilation and lung deformation. Lobar distributions of air volume change during tidal breathing were correlated with those of deep breathing (R2 ≈ 0.84). Small discrepancies between tidal and deep breathing were shown to be likely due to different distributions of air volume change in the left and the right lungs. We also demonstrated an asymmetric characteristic of flow rate between inhalation and exhalation. With ADI, we were able to quantify nonlinearity and hysteresis of lung deformation that can only be captured in dynamic images. Nonlinearity quantified by ADI is greater during inhalation, and it is stronger in the lower lobes (P < 0.05). Lung hysteresis estimated by the difference of ADI between inhalation and exhalation is more significant in the right lungs than that in the left lungs. PMID:26316512
James, Iyore Ao; Moukalled, Ahmad; Yu, Elizabeth; Tulman, David B; Bergese, Sergio D; Jones, Christian D; Stawicki, Stanislaw Pa; Evans, David C
2014-10-01
Clearance of cervical spine injury (CSI) in the obtunded or comatose blunt trauma patient remains controversial. In patients with unreliable physical examination and no evidence of CSI on computed tomography (CT), magnetic resonance imaging of the cervical spine (CS-MRI) is the typical follow-up study. There is a growing body of evidence suggesting that CS-MRI is unnecessary with negative findings on a multi-detector CT (MDCT) scan. This review article systematically analyzes current literature to address the controversies surrounding clearance of CSI in obtunded blunt trauma patients. A literature search through MEDLINE database was conducted using all databases on the National Center for Biotechnology Information (NCBI) website (www.ncbi.nlm.nih.gov) for keywords: "cervical spine injury," "obtunded," and "MRI." The search was limited to studies published within the last 10 years and with populations of patients older than 18 years old. Eleven studies were included in the analysis yielding data on 1535 patients. CS-MRI detected abnormalities in 256 patients (16.6%). The abnormalities reported on CS-MRI resulted in prolonged rigid c-collar immobilization in 74 patients (4.9%). Eleven patients (0.7%) had unstable injury detected on CS-MRI alone that required surgical intervention. In the obtunded blunt trauma patient with unreliable clinical examination and a normal CT scan, there is still a role for CS-MRI in detecting clinically significant injuries when MRI resources are available. However, when a reliable clinical exam reveals intact gross motor function, CS-MRI may be unnecessary.
Kim, Jin Young; Kim, See Hyung; Lee, Hee Jung; Kim, Young Hwan; Kim, Mi Jeong; Cho, Seung Hyun
2014-01-01
PURPOSE We aimed to assess the value of adrenal venous sampling (AVS) for diagnosing primary aldosteronism (PA) subtypes in patients with a unilateral nodule detected on adrenal computed tomography (CT) and scheduled for adrenalectomy. MATERIALS AND METHODS This retrospective study included 80 consecutive patients with PA undergoing CT and AVS. Different lateralization indices were assessed, and a cutoff established using receiver operating characteristic curve analysis. The value of CT alone versus CT with AVS for differentiating PA subtypes was compared. The adrenalectomy outcome was assessed, and predictors of cure were determined using univariate analysis. RESULTS AVS was successful in 68 patients. A cortisol-corrected aldosterone affected-to-unaffected ratio cutoff of 2.0 and affected-to-inferior vena cava ratio cutoff of 1.4 were the best lateralization indices, with accuracies of 82.5% and 80.4%, respectively. CT and AVS diagnosed 38 patients with aldosterone-producing adenomas, five patients with unilateral adrenal hyperplasia, and 25 patients with bilateral adrenal hyperplasia. Of the 52 patients with a nodule detected on CT, subsequent AVS diagnosed bilateral adrenal hyperplasia in 14 patients (27%). Compared to the results of combining CT with AVS, the accuracy of CT alone for diagnosing aldosterone-producing adenomas was 71.1% (P < 0.001). The cure rate for hypertension after adrenalectomy was 39.2%, with improvement in 53.5% of patients. On univariate analysis, predictors of persistent hypertension were male gender and preoperative systolic blood pressure. CONCLUSION To avoid inappropriate surgery, AVS is necessary for diagnosing unilateral nodules with aldosterone hypersecretion detected by CT. PMID:24047720
Multidetector Computed Tomography for Congenital Anomalies of the Aortic Arch: Vascular Rings.
García-Guereta, Luis; García-Cerro, Estefanía; Bret-Zurita, Montserrat
2016-07-01
The development of multidetector computed tomography has triggered a revolution in the study of the aorta and other large vessels and has replaced angiography in the diagnosis of congenital anomalies of the aortic arch, particularly vascular rings. The major advantage of multidetector computed tomography is that it permits clear 3-dimensional assessment of not only vascular structures, but also airway and esophageal compression. The current update aims to summarize the embryonic development of the aortic arch and the developmental anomalies leading to vascular ring formation and to discuss the current diagnostic and therapeutic role of multidetector computed tomography in this field. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.
Physiological and Computed Tomographic Predictors of Outcome from Lung Volume Reduction Surgery
Washko, George R.; Martinez, Fernando J.; Hoffman, Eric A.; Loring, Stephen H.; Estépar, Raúl San José; Diaz, Alejandro A.; Sciurba, Frank C.; Silverman, Edwin K.; Han, MeiLan K.; DeCamp, Malcolm; Reilly, John J.
2010-01-01
Rationale: Previous investigations have identified several potential predictors of outcomes from lung volume reduction surgery (LVRS). A concern regarding these studies has been their small sample size, which may limit generalizability. We therefore sought to examine radiographic and physiologic predictors of surgical outcomes in a large, multicenter clinical investigation, the National Emphysema Treatment Trial. Objectives: To identify objective radiographic and physiological indices of lung disease that have prognostic value in subjects with chronic obstructive pulmonary disease being evaluated for LVRS. Methods: A subset of the subjects undergoing LVRS in the National Emphysema Treatment Trial underwent preoperative high-resolution computed tomographic (CT) scanning of the chest and measures of static lung recoil at total lung capacity (SRtlc) and inspiratory resistance (Ri). The relationship between CT measures of emphysema, the ratio of upper to lower zone emphysema, CT measures of airway disease, SRtlc, Ri, the ratio of residual volume to total lung capacity (RV/TLC), and both 6-month postoperative changes in FEV1 and maximal exercise capacity were assessed. Measurements and Main Results: Physiological measures of lung elastic recoil and inspiratory resistance were not correlated with improvement in either the FEV1 (R = −0.03, P = 0.78 and R = –0.17, P = 0.16, respectively) or maximal exercise capacity (R = –0.02, P = 0.83 and R = 0.08, P = 0.53, respectively). The RV/TLC ratio and CT measures of emphysema and its upper to lower zone ratio were only weakly predictive of postoperative changes in both the FEV1 (R = 0.11, P = 0.01; R = 0.2, P < 0.0001; and R = 0.23, P < 0.0001, respectively) and maximal exercise capacity (R = 0.17, P = 0.0001; R = 0.15, P = 0.002; and R = 0.15, P = 0.002, respectively). CT assessments of airway disease were not predictive of change in FEV1 or exercise capacity in this cohort. Conclusions: The RV/TLC ratio and CT measures of emphysema and its distribution are weak but statistically significant predictors of outcome after LVRS. PMID:19965810
Prakash, Priyanka; Gilman, Matthew D.; Shepard, Jo-Anne O.; Digumarthy, Subba R.
2010-01-01
Objective To assess the effects of radiation dose reduction in the chest CT using a weight-based adjustment of the automatic exposure control (AEC) technique. Materials and Methods With Institutional Review Board Approval, 60 patients (mean age, 59.1 years; M:F = 35:25) and 57 weight-matched patients (mean age, 52.3 years, M:F = 25:32) were scanned using a weight-adjusted AEC and non-weight-adjusted AEC, respectively on a 64-slice multidetector CT with a 0.984:1 pitch, 0.5 second rotation time, 40 mm table feed/rotation, and 2.5 mm section thickness. Patients were categorized into 3 weight categories; < 60 kg (n = 17), 60-90 kg (n = 52), and > 90 kg (n = 48). Patient weights, scanning parameters, CT dose index volumes (CTDIvol) and dose length product (DLP) were recorded, while effective dose (ED) was estimated. Image noise was measured in the descending thoracic aorta. Data were analyzed using a standard statistical package (SAS/STAT) (Version 9.1, SAS institute Inc, Cary, NC). Results Compared to the non-weight-adjusted AEC, the weight-adjusted AEC technique resulted in an average decrease of 29% in CTDIvol and a 27% effective dose reduction (p < 0.0001). With weight-adjusted AEC, the CTDIvol decreased to 15.8, 15.9, and 27.3 mGy for the < 60, 60-90 and > 91 kg weight groups, respectively, compared to 20.3, 27.9 and 32.8 mGy, with non-weight-adjusted AEC. No significant difference was observed for objective image noise between the chest CT acquired with the non-weight-adjusted (15.0 ± 3.1) and weight-adjusted (16.1 ± 5.6) AEC techniques (p > 0.05). Conclusion The results of this study suggest that AEC should be tailored according to patient weight. Without weight-based adjustment of AEC, patients are exposed to a 17 - 43% higher radiation-dose from a chest CT. PMID:20046494
A measurement-based generalized source model for Monte Carlo dose simulations of CT scans
Ming, Xin; Feng, Yuanming; Liu, Ransheng; Yang, Chengwen; Zhou, Li; Zhai, Hezheng; Deng, Jun
2018-01-01
The goal of this study is to develop a generalized source model (GSM) for accurate Monte Carlo dose simulations of CT scans based solely on the measurement data without a priori knowledge of scanner specifications. The proposed generalized source model consists of an extended circular source located at x-ray target level with its energy spectrum, source distribution and fluence distribution derived from a set of measurement data conveniently available in the clinic. Specifically, the central axis percent depth dose (PDD) curves measured in water and the cone output factors measured in air were used to derive the energy spectrum and the source distribution respectively with a Levenberg-Marquardt algorithm. The in-air film measurement of fan-beam dose profiles at fixed gantry was back-projected to generate the fluence distribution of the source model. A benchmarked Monte Carlo user code was used to simulate the dose distributions in water with the developed source model as beam input. The feasibility and accuracy of the proposed source model was tested on a GE LightSpeed and a Philips Brilliance Big Bore multi-detector CT (MDCT) scanners available in our clinic. In general, the Monte Carlo simulations of the PDDs in water and dose profiles along lateral and longitudinal directions agreed with the measurements within 4%/1mm for both CT scanners. The absolute dose comparison using two CTDI phantoms (16 cm and 32 cm in diameters) indicated a better than 5% agreement between the Monte Carlo-simulated and the ion chamber-measured doses at a variety of locations for the two scanners. Overall, this study demonstrated that a generalized source model can be constructed based only on a set of measurement data and used for accurate Monte Carlo dose simulations of patients’ CT scans, which would facilitate patient-specific CT organ dose estimation and cancer risk management in the diagnostic and therapeutic radiology. PMID:28079526
Wielpütz, Mark O; Heußel, Claus P; Herth, Felix J F; Kauczor, Hans-Ulrich
2014-03-14
Chest X-ray, computed tomography (CT), and magnetic resonance imaging (MRI) each have characteristic advantages and disadvantages that need to be considered in clinical decision-making. This point is discussed in reference to the main types of lung disease that are encountered in practice. A selective literature search was performed in the PubMed and Google Scholar databases. Existing clinical guidelines on the main types of lung disease and studies concerning radiological diagnosis were also con - sidered in this review. There have been no more than a few large-scale, controlled comparative trials of different radiological techniques. Chest X-ray provides general orientation as an initial diagnostic study and is especially useful in the diagnosis of pneumonia, cancer, and chronic obstructive pulmonary disease (COPD). Multi-detector CT affords nearly isotropic spatial resolution at a radiation dose of only 0.2-5 mSv, much lower than before. Its main indications, according to current guidelines, are tumors, acute pulmonary embolism, pulmonary hypertension, pulmonary fibrosis, advanced COPD, and pneumonia in a high-risk patient. MRI is used in the diagnosis of cystic fibrosis, pulmonary embolism, pulmonary hypertension, and bronchial carcinoma. The positive predictive value (PPV) of a chest X-ray in outpatients with pneumonia is only 27% (gold standard, CT); in contrast, an initial, non-randomized trial of MRI in nosocomial pneumonia revealed a PPV of 95%. For the staging of mediastinal lymph nodes in bronchial carcinoma, MRI has a PPV of 88% and positron emission tomography with CT (PET/CT) has a PPV of 79%, while CT alone has a PPV of 41% (gold standard, histology). The choice of radiologicalal technique for the detection, staging, follow-up, and quantification of lung disease should be based on the individual clinical options, so that appropriate treatment can be provided without excessive use of diagnostic testing.
Prakash, Priyanka; Kalra, Mannudeep K; Gilman, Matthew D; Shepard, Jo-Anne O; Digumarthy, Subba R
2010-01-01
To assess the effects of radiation dose reduction in the chest CT using a weight-based adjustment of the automatic exposure control (AEC) technique. With Institutional Review Board Approval, 60 patients (mean age, 59.1 years; M:F = 35:25) and 57 weight-matched patients (mean age, 52.3 years, M:F = 25:32) were scanned using a weight-adjusted AEC and non-weight-adjusted AEC, respectively on a 64-slice multidetector CT with a 0.984:1 pitch, 0.5 second rotation time, 40 mm table feed/rotation, and 2.5 mm section thickness. Patients were categorized into 3 weight categories; < 60 kg (n = 17), 60-90 kg (n = 52), and > 90 kg (n = 48). Patient weights, scanning parameters, CT dose index volumes (CTDIvol) and dose length product (DLP) were recorded, while effective dose (ED) was estimated. Image noise was measured in the descending thoracic aorta. Data were analyzed using a standard statistical package (SAS/STAT) (Version 9.1, SAS institute Inc, Cary, NC). Compared to the non-weight-adjusted AEC, the weight-adjusted AEC technique resulted in an average decrease of 29% in CTDIvol and a 27% effective dose reduction (p < 0.0001). With weight-adjusted AEC, the CTDIvol decreased to 15.8, 15.9, and 27.3 mGy for the < 60, 60-90 and > 91 kg weight groups, respectively, compared to 20.3, 27.9 and 32.8 mGy, with non-weight-adjusted AEC. No significant difference was observed for objective image noise between the chest CT acquired with the non-weight-adjusted (15.0 +/- 3.1) and weight-adjusted (16.1 +/- 5.6) AEC techniques (p > 0.05). The results of this study suggest that AEC should be tailored according to patient weight. Without weight-based adjustment of AEC, patients are exposed to a 17 - 43% higher radiation-dose from a chest CT.
Kadhim, Lujaien A; Dholakia, Avani S; Herman, Joseph M; Wahl, Richard L; Chaudhry, Muhammad A
2013-12-01
Pancreatic cancer continues to have a grim prognosis with 5-year survival rates at less than 5 %. It is a particularly challenging health problem given these poor survival outcomes, aggressive tumor biology, and late onset of symptoms. Most patients present with advanced unresectable cancer however, margin-negative resection provides a rare chance for cure for patients with resectable disease. The standard imaging modality for the diagnosis and management of pancreatic cancer is contrast-enhanced multidetector computed tomography. Remarkable advances in CT technology have led to improvements in the ability to detect small tumors and intricate vasculature involvement by the tumor, yet CT is still restricted to providing a morphological portrait of the tumor. Diagnosis can be challenging due to similar appearance of certain benign and malignant disease. Distant metastatic disease can be silent on CT leading to improper staging, and thus management, of certain patients. Furthermore, radiation-induced fibrosis and necrosis complicate assessment of treatment response by CT alone. F-fluorodeoxyglucose positron emission tomography ( 18 F-FDG-PET) is becoming a prevalent tool employed by physicians to improve accuracy in these clinical scenarios. Malignant transformation causes a high metabolic activity of cancer cells. 18 F-FDG-PET captures this functional activity of malignancies by capturing areas with high glucose utilization rates. Imaging function rather than morphological appearance, 18 F-FDG-PET has a unique role in the management of oncology patients with the ability to detect regions of tumor involvement that may be silent on conventional imaging. Literature on the sensitivity and specificity of 18 F-FDG-PET fails to reach a consensus, and improvements resulting in hybridization of 18 F-FDG-PET and CT imaging techniques are preliminary. Here we review the potential role of 18 F-FDG-PET and PET/CT in improving accuracy in the initial evaluation and subsequent steps in the management of pancreatic cancer patients.
Dang, Pragya; Singh, Sarabjeet; Saini, Sanjay; Shepard, Jo-Anne O.
2009-01-01
Objective To assess effects of off-centering, automatic exposure control, and padding on attenuation values, noise, and radiation dose when using in-plane bismuth-based shields for CT scanning. Materials and Methods A 30 cm anthropomorphic chest phantom was scanned on a 64-multidetector CT, with the center of the phantom aligned to the gantry isocenter. Scanning was repeated after placing a bismuth breast shield on the anterior surface with no gap and with 1, 2, and 6 cm of padding between the shield and the phantom surface. The "shielded" phantom was also scanned with combined modulation and off-centering of the phantom at 2 cm, 4 cm and 6 cm below the gantry isocenter. CT numbers, noise, and surface radiation dose were measured. The data were analyzed using an analysis of variance. Results The in-plane shield was not associated with any significant increment for the surface dose or CT dose index volume, which was achieved by comparing the radiation dose measured by combined modulation technique to the fixed mAs (p > 0.05). Irrespective of the gap or the surface CT numbers, surface noise increased to a larger extent compared to Hounsfield unit (HU) (0-6 cm, 26-55%) and noise (0-6 cm, 30-40%) in the center. With off-centering, in-plane shielding devices are associated with less dose savings, although dose reduction was still higher than in the absence of shielding (0 cm off-center, 90% dose reduction; 2 cm, 61%) (p < 0.0001). Streak artifacts were noted at 0 cm and 1 cm gaps but not at 2 cm and 6 cm gaps of shielding to the surface distances. Conclusion In-plane shields are associated with greater image noise, artifactually increased attenuation values, and streak artifacts. However, shields reduce radiation dose regardless of the extent of off-centering. Automatic exposure control did not increase radiation dose when using a shield. PMID:19270862
Evaluation of simethicone-coated cellulose as a negative oral contrast agent for abdominal CT.
Sahani, Dushyant V; Jhaveri, Kartik S; D'souza, Roy V; Varghese, Jose C; Halpern, Elkan; Harisinghani, Mukesh G; Hahn, Peter F; Saini, Sanjay
2003-05-01
Because of the increased clinical use of computed tomography (CT) for imaging the abdominal vasculature and urinary tract, there is a need for negative contrast agents. The authors undertook this study to assess the suitability of simethicone-coated cellulose (SCC), which is approved for use as an oral contrast agent in sonography, for use as a negative oral contrast agent in abdominal CT. This prospective study involved 40 adult patients scheduled to undergo abdominal CT for the evaluation of hematuria. Prior to scanning, 20 subjects received 800 mL of SCC and 20 received 800 mL of water as an oral contrast agent. Imaging was performed with a multi-detector row helical scanner in two phases, according to the abdominal CT protocol used for hematuria evaluation at the authors' institution. The first, "early" phase began an average of 15 minutes after the ingestion of contrast material; the second, "late" phase began an average of 45 minutes after the ingestion of contrast material. Blinded analysis was performed by three abdominal radiologists separately, using a three-point scale (0 = poor, 1 = acceptable, 2 = excellent) to assess the effectiveness of SCC for marking the proximal, middle, and distal small bowel. Average scores for enhancement with SCC and with water were obtained and compared. Statistical analysis was performed with a Wilcoxon signed-rank test. SCC was assigned higher mean scores than water for enhancement in each segment of the bowel, both on early-phase images (0.8-1.35 for SCC vs 0.6-1.1 for water) and on late-phase images (1.1-1.4 vs 0.81-0.96). Bowel marking with SCC, particularly in the jejunum and ileum, also was rated better than that with water in a high percentage of patients. The differences between the scores for water and for SCC, however, were not statistically significant (P > .05). SCC is effective as a negative oral contrast agent for small bowel marking at CT.
A measurement-based generalized source model for Monte Carlo dose simulations of CT scans
NASA Astrophysics Data System (ADS)
Ming, Xin; Feng, Yuanming; Liu, Ransheng; Yang, Chengwen; Zhou, Li; Zhai, Hezheng; Deng, Jun
2017-03-01
The goal of this study is to develop a generalized source model for accurate Monte Carlo dose simulations of CT scans based solely on the measurement data without a priori knowledge of scanner specifications. The proposed generalized source model consists of an extended circular source located at x-ray target level with its energy spectrum, source distribution and fluence distribution derived from a set of measurement data conveniently available in the clinic. Specifically, the central axis percent depth dose (PDD) curves measured in water and the cone output factors measured in air were used to derive the energy spectrum and the source distribution respectively with a Levenberg-Marquardt algorithm. The in-air film measurement of fan-beam dose profiles at fixed gantry was back-projected to generate the fluence distribution of the source model. A benchmarked Monte Carlo user code was used to simulate the dose distributions in water with the developed source model as beam input. The feasibility and accuracy of the proposed source model was tested on a GE LightSpeed and a Philips Brilliance Big Bore multi-detector CT (MDCT) scanners available in our clinic. In general, the Monte Carlo simulations of the PDDs in water and dose profiles along lateral and longitudinal directions agreed with the measurements within 4%/1 mm for both CT scanners. The absolute dose comparison using two CTDI phantoms (16 cm and 32 cm in diameters) indicated a better than 5% agreement between the Monte Carlo-simulated and the ion chamber-measured doses at a variety of locations for the two scanners. Overall, this study demonstrated that a generalized source model can be constructed based only on a set of measurement data and used for accurate Monte Carlo dose simulations of patients’ CT scans, which would facilitate patient-specific CT organ dose estimation and cancer risk management in the diagnostic and therapeutic radiology.
Hwang, Jeong-Hwa; Misumi, Shigeki; Curran-Everett, Douglas; Brown, Kevin K; Sahin, Hakan; Lynch, David A
2011-08-01
The aim of this study was to evaluate the prognostic implications of computed tomography (CT) and physiologic variables at baseline and on sequential evaluation in patients with fibrosing interstitial pneumonia. We identified 72 patients with fibrosing interstitial pneumonia (42 with idiopathic disease, 30 with collagen vascular disease). Pulmonary function tests and CT were performed at the time of diagnosis and at a median follow-up of 12 months, respectively. Two chest radiologists scored the extent of specific abnormalities and overall disease on baseline and follow-up CT. Rate of survival was estimated using the Kaplan-Meier method. Three Cox proportional hazards models were constructed to evaluate the relationship between CT and physiologic variables and rate of survival: model 1 included only baseline variables, model 2 included only serial change variables, and model 3 included both baseline and serial change variables. On follow-up CT, the extent of mixed ground-glass and reticular opacities (P<0.001), pure reticular opacity (P=0.04), honeycombing (P=0.02), and overall extent of disease (P<0.001) was increased in the idiopathic group, whereas these variables remained unchanged in the collagen vascular disease group. Patients with idiopathic disease had a shorter rate of survival than those with collagen vascular disease (P=0.03). In model 1, the extent of honeycombing on baseline CT was the only independent predictor of mortality (P=0.02). In model 2, progression in honeycombing was the only predictor of mortality (P=0.005). In model 3, baseline extent of honeycombing and progression of honeycombing were the only independent predictors of mortality (P=0.001 and 0.002, respectively). Neither baseline nor serial change physiologic variables, nor the presence of collagen vascular disease, was predictive of rate of survival. The extent of honeycombing at baseline and its progression on follow-up CT are important determinants of rate of survival in patients with fibrosing interstitial pneumonia.
Emergency department imaging: are weather and calendar factors associated with imaging volume?
Burns, K; Chernyak, V; Scheinfeld, M H
2016-12-01
To identify weather and calendar factors that would enable prediction of daily emergency department (ED) imaging volume to aid appropriate scheduling of imaging resources for efficient ED function. Daily ED triage and imaging volumes for radiography, computed tomography (CT), and ultrasound were obtained from hospital databases for the period between January 2011 and December 2013 at a large tertiary urban hospital with a Level II trauma centre. These data were tabulated alongside daily weather conditions (temperature, wind and precipitation), day of week, season, and holidays. Multivariate analysis was performed. Pearson correlations were used to measure the association between number of imaging studies performed and ED triage volume. For every additional 50 triaged patients, the odds of having high (imaging volume ≥90th percentile) radiography, CT, and ultrasound volume increased by 4.3 times (p<0.001), 1.5 times (p=0.02), and 1.4 times (p=0.02), respectively. Tuesday was an independent predictor of high radiography volume (odds ratio=2.8) and Monday was an independent predictor of high CT volume (odds ratio=3.0). Weekday status was an independent factor increasing the odds of a high US volume compared to Saturday (odds ratios ranging from 5.6-9.8). Weather factors and other calendar variables were not independent predictors of high imaging volume. Using Pearson correlations, ED triage volume correlated with number of radiographs, CT, and ultrasound examinations with r=0.73, 0.37, and 0.41, respectively (p<0.0001). As ED triage volume was found to be the only factor associated with imaging volume for all techniques, analysis of predictors of ED triage volumes at a particular healthcare facility would be useful to determine imaging needs. Although calendar and weather factors were found to be minor or non-significant independent predictors of ED imaging utilisation, these may be important in influencing the actual number of ED triages. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Camera, Luigi; Romano, Federica; Liccardo, Immacolata; Liuzzi, Raffaele; Imbriaco, Massimo; Mainenti, Pier Paolo; Pizzuti, Laura Micol; Segreto, Sabrina; Maurea, Simone; Brunetti, Arturo
2015-11-01
As both contrast and radiation dose affect the quality of CT images, a constant image quality in abdominal contrast-enhanced multidetector computed tomography (CE-MDCT) could be obtained balancing radiation and contrast media dose according to the age of the patients. Seventy-two (38 Men; 34 women; aged 20-83 years) patients underwent a single-pass abdominal CE-MDCT. Patients were divided into three different age groups: A (20-44 years); B (45-65 years); and C (>65 years). For each group, a different noise index (NI) and contrast media dose (370 mgI/mL) was selected as follows: A (NI, 15; 2.5 mL/kg), B (NI, 12.5; 2 mL/kg), and C (NI, 10; 1.5 mL/kg). Radiation exposure was reported as dose-length product (DLP) in mGy × cm. For quantitative analysis, signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were calculated for both the liver (L) and the abdominal aorta (A). Statistical analysis was performed with a one-way analysis of variance. Standard imaging criteria were used for qualitative analysis. Although peak hepatic enhancement was 152 ± 16, 128 ± 12, and 101 ± 14 Hounsfield units (P < .001) for groups A, B, and C, respectively, no significant differences were observed in the corresponding SNRL with 9.2 ± 1.4, 9.1 ± 1.2, and 9.2 ± 3. Radiation (mGy × cm) and contrast media dose (mL) administered were 476 ± 147 and 155 ± 27 for group A, 926 ± 291 and 130 ± 16 for group B, and 1981 ± 451 and 106 ± 15 for group C, respectively (P < .001). None of the studies was graded as poor or inadequate by both readers, and the prevalence-adjusted bias-adjusted kappa ranged between 0.48 and 0.93 for all but one criteria. A constant image quality in CE-MDCT can be obtained balancing radiation and contrast media dose administered to patients of different age. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kruger, R.
The US National Lung Screening Trial (NLST) was a multi-center randomized, controlled trial comparing a low-dose CT (LDCT) to posterior-anterior (PA) chest x-ray (CXR) in screening older, current and former heavy smokers for early detection of lung cancer. Recruitment was launched in September 2002 and ended in April 2004 when 53,454 participants had been randomized at 33 screening sites in equal proportions. Funded by the National Cancer Institute this trial demonstrated that LDCT screening reduced lung cancer mortality. The US Preventive Services Task Force (USPSTF) cited NLST findings and conclusions in its deliberations and analysis of lung cancer screening. Undermore » the 2010 Patient Protection and Affordable Care Act, the USPSTF favorable recommendation regarding lung cancer CT screening assisted in obtaining third-party payers coverage for screening. The objective of this session is to provide an introduction to the NLST and the trial findings, in addition to a comprehensive review of the dosimetry investigations and assessments completed using individual NLST participant CT and CXR examinations. Session presentations will review and discuss the findings of two independent assessments, a CXR assessment and the findings of a CT investigation calculating individual organ dosimetry values. The CXR assessment reviewed a total of 73,733 chest x-ray exams that were performed on 92 chest imaging systems of which 66,157 participant examinations were used. The CT organ dosimetry investigation collected scan parameters from 23,773 CT examinations; a subset of the 75,133 CT examinations performed using 97 multi-detector CT scanners. Organ dose conversion coefficients were calculated using a Monte Carlo code. An experimentally-validated CT scanner simulation was coupled with 193 adult hybrid computational phantoms representing the height and weight of the current U.S. population. The dose to selected organs was calculated using the organ dose library and the abstracted scan parameters. This session will review the results and summarize the individualized doses to major organs and the mean effective dose and CTDIvol estimate for 66,157 PA chest and 23,773 CT examinations respectively, using size-dependent computational phantoms coupled with Monte Carlo calculations. Learning Objectives: Review and summarize relevant NLST findings and conclusions. Understand the scope and scale of the NLST specific to participant dosimetry. Provide a comprehensive review of NLST participant dosimetry assessments. Summarize the results of an investigation providing individualized organ dose estimates for NLST participant cohorts.« less
O'Donnell, C; Iino, M; Mansharan, K; Leditscke, J; Woodford, N
2011-02-25
CT scanning of the deceased is an established technique performed on all individuals admitted to VIFM over the last 5 years. It is used primarily to assist pathologists in determining cause and manner of death but is also invaluable for identification of unknown deceased individuals where traditional methods are not possible. Based on this experience, CT scanning was incorporated into phase 2 of the Institute's DVI process for the 2009 Victorian bushfires. All deceased individuals and fragmented remains admitted to the mortuary were CT scanned in their body bags using established protocols. Images were reviewed by 2 teams of 2 radiologists experienced in forensic imaging and the findings transcribed onto a data sheet constructed specifically for the DVI exercise. The contents of 255 body bags were examined in the 28 days following the fires. 164 missing persons were included in the DVI process with 163 deceased individuals eventually identified. CT contributed to this identification in 161 persons. In 2 cases, radiologists were unable to recognize commingled remains. CT was utilized in the initial triage of each bag's contents. If radiological evaluation determined that bodies were incomplete then this information was provided to search teams who revisited the scenes of death. CT was helpful in differentiation of human from non-human remains in 8 bags, recognition of human/animal commingling in 10 bags and human commingling in 6 bags. In 61% of cases gender was able to be determined on CT using a novel technique of genitalia detection and in all but 2 cases this was correct. Age range was able to be determined on CT in 94% with an accuracy of 76%. Specific identification features detected on CT included the presence of disease (14 disease entities in 13 cases), medical devices (26 devices in 19 cases) and 274 everyday metallic items associated with the remains of 135 individuals. CT scanning provided useful information prior to autopsy by flagging likely findings including the presence of non-human remains, at the time of autopsy by assisting in the localization of identifying features in heavily disfigured bodies, and after autopsy by retrospective review of images for clarification of issues that arose at the time of pathologist case review. In view of the success of CT scanning in this mass disaster, DVI administrators should explore the incorporation of CT services into their disaster plans. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Is radiography justified for the evaluation of patients presenting with cervical spine trauma?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Theocharopoulos, Nicholas; Chatzakis, Georgios; Damilakis, John
2009-10-15
Conventional radiography has been for decades the standard method of evaluation for cervical spine trauma patients. However, currently available helical multidetector CT scanners allow multiplanar reconstruction of images, leading to increased diagnostic accuracy. The purpose of this study was to determine the relative benefit/risk ratio between cervical spine CT and cervical spine radiography and between cervical spine CT and cervical spine radiography, followed by CT as an adjunct for positive findings. A decision analysis model for the determination of the optimum imaging technique was developed. The sensitivity and specificity of CT and radiography were obtained by dedicated meta-analysis. Lifetime attributablemore » risk of mortal cancer from CT and radiography was calculated using updated organ-specific risk coefficients and organ-absorbed doses. Patient organ doses from radiography were calculated using Monte Carlo techniques, simulated exposures performed on an anthropomorphic phantom, and thermoluminescence dosimetry. A prospective patient study was performed regarding helical CT scans of the cervical spine. Patient doses were calculated based on the dose-length-product values and Monte Carlo-based CT dosimetry software program. Three groups of patient risk for cervical spine fracture were incorporated in the decision model on the basis of hypothetical trauma mechanism and clinical findings. Radiation effects were assessed separately for males and females for four age groups (20, 40, 60, and 80 yr old). Effective dose from radiography amounts to 0.050 mSv and from a typical CT scan to 3.8 mSv. The use of CT in a hypothetical cohort of 10{sup 6} patients prevents approximately 130 incidents of paralysis in the low risk group (a priori fracture probability of 0.5%), 500 in the moderate risk group (a priori fracture probability of 2%), and 5100 in the high risk group (a priori fracture probability of 20%). The expense of this CT-based prevention is 15-32 additional radiogenic lethal cancer incidents. According to the decision model calculations, the use of CT is more favorable over the use of radiography alone or radiography with CT by a factor of 13, for low risk 20 yr old patients, to a factor of 23, for high risk patients younger than 80 yr old. The radiography/CT imaging strategy slightly outperforms plain radiography for high and moderate risk patients. Regardless of the patient age, sex, and fracture risk, the higher diagnostic accuracy obtained by the CT examination counterbalances the increase in dose compared to plain radiography or radiography followed by CT only for positive radiographs and renders CT utilization justified and the radiographic screening redundant.« less
Long-term recovery of normal sexual function in testicular cancer survivors.
Capogrosso, Paolo; Boeri, Luca; Ferrari, Matteo; Ventimiglia, Eugenio; La Croce, Giovanni; Capitanio, Umberto; Briganti, Alberto; Damiano, Rocco; Montorsi, Francesco; Salonia, Andrea
2016-01-01
Testicular cancer (TC) is the most common solid cancer in men between the third and fourth decade of life. Due to successful treatment approaches, TC survivors (TCSs) have long life expectancy, but with numerous potential long-term sequelae, including sexual dysfunction. We investigated predictors of long-term normal sexual function (SF) recovery in TCSs. Sociodemographic, medical, and psychometric data were analyzed in 143 Caucasian-European TCSs, who underwent orchiectomy at a single institution. Health-significant comorbidities were scored with the Charlson Comorbidity Index (CCI). Patients completed the International Index of Erectile Function (IIEF). Statistical models tested the association between predictors (including age at surgery, body mass index, CCI, and adjuvant therapy: radiotherapy [RT], chemotherapy [CT], CT followed by retroperitoneal lymph node dissection [RPLND] and RPLND alone) and the long-term recovery of normal SF (defined as IIEF-erectile function [EF] ≥26, and sexual desire [SD], intercourse satisfaction [IS] orgasmic function [OF], and overall satisfaction [OS] domain scores in the upper tertiles). At a mean follow-up of 86 months, 35 (25.5%) TCSs had erectile dysfunction (ED), with 16 (11.2%) experiencing severe ED. Median time of EF recovery was 60, 60, and 70 months after CT, RT, and RPLND, respectively. Only adjuvant RT emerged as an independent predictor of nonrecovery of normal EF (HR: 0.55, P= 0.01). Neither adjuvant CT nor CT plus RPLND or RPLND alone significantly impaired the recovery of normal erections. Adjuvant therapy was not associated with impaired recovery of normal sexuality as a whole, considering the IIEF-SD, -OF, -IS, and OS domains.
Shedd-Wise, Kristine M; Alekel, D Lee; Hofmann, Heike; Hanson, Kathy B; Schiferl, Dan J; Hanson, Laura N; Van Loan, Marta D
2011-01-01
Soy isoflavones exert inconsistent bone density-preserving effects, but the bone strength-preserving effects in humans are unknown. Our double-blind randomized controlled trial examined 2 soy isoflavone doses (80 or 120mg/d) vs placebo tablets on volumetric bone mineral density (vBMD) and strength (by means of peripheral quantitative computed tomography) in healthy postmenopausal women (46-63yr). We measured 3-yr changes in cortical BMD (CtBMD), cortical thickness (CtThk), periosteal circumference (PC), endosteal circumference (EC), and strength-strain index (SSI) at 1/3 midshaft femur (N=171), and trabecular BMD (TbBMD), PC, and SSI at 4% distal tibia (N=162). We found no treatment effect on femur CtThk, PC, or EC, or tibia TbBMD or PC. The strongest predictors (negative) of tibia TbBMD and SSI and femur CtBMD were timepoint and bone resorption; whole-body fat mass was protective of SSI. As time since last menstrual period (TLMP) increased (p=0.012), 120-mg/d dose was protective of CtBMD. The strongest predictors of femur SSI were timepoint, bone resorption, and TLMP (protective). Isoflavone tablets were negative predictors of SSI, but 80-mg/d dose became protective as bone turnover increased (p=0.011). Soy isoflavone treatment for 3yr was modestly beneficial for midshaft femur vBMD as TLMP increased and for midshaft femur SSI as bone turnover increased. Copyright © 2011 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.
[Contrast-enhanced ultrasound in animal models].
Paprottka, P M; Zengel, P; Ingrisch, M; Cyran, C C; Eichhorn, M; Reiser, M F; Nikolaou, K; Clevert, D-A
2011-06-01
In the past the detection of tumor perfusion was achieved solely via invasive procedures, such as intravital microscopy or with the help of costly modalities, such as multidetector computed tomography (MDCT), magnetic resonance tomography (MRT) or the combined use of positron emission tomography and computed tomography (PET/CT). Ultrasound offers the non-invasive display of organs without usage of ionizing radiation and it is widely available. However, colour-coded ultrasound and power Doppler do not allow the detection of tumor microcirculation. The introduction of contrast-enhanced ultrasound (CEUS) as well as new high-frequency ultrasound probes made it possible to detect and quantify tumor microcirculation with high resolution. CEUS has been used clinically on human beings for more than 10 years. During the last years different tumor models in experimental animals were used for the establishment of this new technique, e.g. in rats, hamsters and mice. CEUS allows the detection of functional parameters, such as the angiogenetic metabolic status of tissue pretreatment and posttreatment. Further research is required to solve the problems of absolute quantification of these perfusion parameters to allow the comparison of CEUS with other modalities (e.g. MRT and CT).
Kim, Sangroh; Yoshizumi, Terry; Toncheva, Greta; Yoo, Sua; Yin, Fang-Fang; Frush, Donald
2010-05-01
To address the lack of accurate dose estimation method in cone beam computed tomography (CBCT), we performed point dose metal oxide semiconductor field-effect transistor (MOSFET) measurements and Monte Carlo (MC) simulations. A Varian On-Board Imager (OBI) was employed to measure point doses in the polymethyl methacrylate (PMMA) CT phantoms with MOSFETs for standard and low dose modes. A MC model of the OBI x-ray tube was developed using BEAMnrc/EGSnrc MC system and validated by the half value layer, x-ray spectrum and lateral and depth dose profiles. We compared the weighted computed tomography dose index (CTDIw) between MOSFET measurements and MC simulations. The CTDIw was found to be 8.39 cGy for the head scan and 4.58 cGy for the body scan from the MOSFET measurements in standard dose mode, and 1.89 cGy for the head and 1.11 cGy for the body in low dose mode, respectively. The CTDIw from MC compared well to the MOSFET measurements within 5% differences. In conclusion, a MC model for Varian CBCT has been established and this approach may be easily extended from the CBCT geometry to multi-detector CT geometry.
Six-Minute Walk Distance Predictors, Including CT Scan Measures, in the COPDGene Cohort
Rambod, Mehdi; Porszasz, Janos; Make, Barry J.; Crapo, James D.
2012-01-01
Background: Exercise tolerance in COPD is only moderately well predicted by airflow obstruction assessed by FEV1. We determined whether other phenotypic characteristics, including CT scan measures, are independent predictors of 6-min walk distance (6MWD) in the COPDGene cohort. Methods: COPDGene recruits non-Hispanic Caucasian and African American current and ex-smokers. Phenotyping measures include postbronchodilator FEV1 % predicted and inspiratory and expiratory CT lung scans. We defined % emphysema as the percentage of lung voxels < −950 Hounsfield units on the inspiratory scan and % gas trapping as the percentage of lung voxels < −856 Hounsfield units on the expiratory scan. Results: Data of the first 2,500 participants of the COPDGene cohort were analyzed. Participant age was 61 ± 9 years; 51% were men; 76% were non-Hispanic Caucasians, and 24% were African Americans. Fifty-six percent had spirometrically defined COPD, with 9.3%, 23.4%, 15.0%, and 8.3% in GOLD (Global Initiative for Chronic Obstructive Lung Disease) stages I to IV, respectively. Higher % emphysema and % gas trapping predicted lower 6MWD (P < .001). However, in a given spirometric group, after adjustment for age, sex, race, and BMI, neither % emphysema nor % gas trapping, or their interactions with FEV1 % predicted, remained a significant 6MWD predictor. In a given spirometric group, only 16% to 27% of the variance in 6MWD could be explained by age, male sex, Caucasian race, and lower BMI as significant predictors of higher 6MWD. Conclusions: In this large cohort of smokers in a given spirometric stage, phenotypic characteristics were only modestly predictive of 6MWD. CT scan measures of emphysema and gas trapping were not predictive of 6MWD after adjustment for other phenotypic characteristics. PMID:21960696
Six-minute walk distance predictors, including CT scan measures, in the COPDGene cohort.
Rambod, Mehdi; Porszasz, Janos; Make, Barry J; Crapo, James D; Casaburi, Richard
2012-04-01
Exercise tolerance in COPD is only moderately well predicted by airflow obstruction assessed by FEV(1). We determined whether other phenotypic characteristics, including CT scan measures, are independent predictors of 6-min walk distance (6MWD) in the COPDGene cohort. COPDGene recruits non-Hispanic Caucasian and African American current and ex-smokers. Phenotyping measures include postbronchodilator FEV(1) % predicted and inspiratory and expiratory CT lung scans. We defined % emphysema as the percentage of lung voxels < -950 Hounsfield units on the inspiratory scan and % gas trapping as the percentage of lung voxels < -856 Hounsfield units on the expiratory scan. Data of the first 2,500 participants of the COPDGene cohort were analyzed. Participant age was 61 ± 9 years; 51% were men; 76% were non-Hispanic Caucasians, and 24% were African Americans. Fifty-six percent had spirometrically defined COPD, with 9.3%, 23.4%, 15.0%, and 8.3% in GOLD (Global Initiative for Chronic Obstructive Lung Disease) stages I to IV, respectively. Higher % emphysema and % gas trapping predicted lower 6MWD (P < .001). However, in a given spirometric group, after adjustment for age, sex, race, and BMI, neither % emphysema nor % gas trapping, or their interactions with FEV(1) % predicted, remained a significant 6MWD predictor. In a given spirometric group, only 16% to 27% of the variance in 6MWD could be explained by age, male sex, Caucasian race, and lower BMI as significant predictors of higher 6MWD. In this large cohort of smokers in a given spirometric stage, phenotypic characteristics were only modestly predictive of 6MWD. CT scan measures of emphysema and gas trapping were not predictive of 6MWD after adjustment for other phenotypic characteristics.
ERIC Educational Resources Information Center
Beutler, Larry E.; And Others
1991-01-01
Compared group cognitive therapy (CT); focused expressive psychotherapy; and supportive, self-directed therapy (S/SD) among 63 patients with major depressive disorder. Results suggest that patient characteristics can be used differentially to assign psychotherapy types. Externalizing patients and low defensive patients improved more in CT;…
Caudri, Daan; Zitter, David; Bronsveld, Inez; Tiddens, Harm
2017-09-01
Cystic Fibrosis (CF) lung disease is characterized by a marked heterogeneity. Sweat chloride-level is a functional marker of the CF Transmembrane Regulator (CFTR) protein and could be an important predictor of later disease severity. In this retrospective analysis children from the Rotterdam CF clinic with available sweat chloride level at diagnosis and at least one routine spirometry-controlled volumetric chest CT scan in follow-up were included. CT scans were scored using the CF-CT scoring system (% of maximum). Associations between sweat chloride-levels and CF-CT scores were calculated using linear regression models, adjusting for age at sweat test and age at follow-up. Because structural lung damage develops over the course of many years, effect modification by the age at follow-up CT-scan was tested for by age-stratification. In 59 children (30 male) sweat chloride was measured at diagnosis (median age 0.5 years, range 0-13) and later chest CT performed (median age 14 years, range 6-18). Sweat chloride was associated with significantly higher CT-CT total score, bronchiectasis score, and mucus plugging score. Stratification for age at follow-up in tertiles showed this association remained only in the oldest age group (range 15-18 years). In that subgroup associations were found with all but one of the CF-CT subscores, as well as with all tested lung functions parameters. Sweat chloride-level is a significant predictor of CF lung disease severity as determined by chest CT and lung function. This association could only be demonstrated in children with follow-up to age 15 years and above. © 2017 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, C.
2015-06-15
The US National Lung Screening Trial (NLST) was a multi-center randomized, controlled trial comparing a low-dose CT (LDCT) to posterior-anterior (PA) chest x-ray (CXR) in screening older, current and former heavy smokers for early detection of lung cancer. Recruitment was launched in September 2002 and ended in April 2004 when 53,454 participants had been randomized at 33 screening sites in equal proportions. Funded by the National Cancer Institute this trial demonstrated that LDCT screening reduced lung cancer mortality. The US Preventive Services Task Force (USPSTF) cited NLST findings and conclusions in its deliberations and analysis of lung cancer screening. Undermore » the 2010 Patient Protection and Affordable Care Act, the USPSTF favorable recommendation regarding lung cancer CT screening assisted in obtaining third-party payers coverage for screening. The objective of this session is to provide an introduction to the NLST and the trial findings, in addition to a comprehensive review of the dosimetry investigations and assessments completed using individual NLST participant CT and CXR examinations. Session presentations will review and discuss the findings of two independent assessments, a CXR assessment and the findings of a CT investigation calculating individual organ dosimetry values. The CXR assessment reviewed a total of 73,733 chest x-ray exams that were performed on 92 chest imaging systems of which 66,157 participant examinations were used. The CT organ dosimetry investigation collected scan parameters from 23,773 CT examinations; a subset of the 75,133 CT examinations performed using 97 multi-detector CT scanners. Organ dose conversion coefficients were calculated using a Monte Carlo code. An experimentally-validated CT scanner simulation was coupled with 193 adult hybrid computational phantoms representing the height and weight of the current U.S. population. The dose to selected organs was calculated using the organ dose library and the abstracted scan parameters. This session will review the results and summarize the individualized doses to major organs and the mean effective dose and CTDIvol estimate for 66,157 PA chest and 23,773 CT examinations respectively, using size-dependent computational phantoms coupled with Monte Carlo calculations. Learning Objectives: Review and summarize relevant NLST findings and conclusions. Understand the scope and scale of the NLST specific to participant dosimetry. Provide a comprehensive review of NLST participant dosimetry assessments. Summarize the results of an investigation providing individualized organ dose estimates for NLST participant cohorts.« less
Determination of Single-Kidney Glomerular Filtration Rate in Human Subjects by Using CT
Kwon, Soon Hyo; Saad, Ahmed; Herrmann, Sandra M.; Textor, Stephen C.
2015-01-01
Purpose To test the hypothesis that computed tomography (CT)–derived measurements of single-kidney glomerular filtration rate (GFR) obtained in human subjects with 64-section CT agree with those obtained with iothalamate clearance, a rigorous reference standard. Materials and Methods The institutional review board approved this HIPAA-compliant study, and written informed consent was obtained. Ninety-six patients (age range, 51–73 years; 46 men, 50 women) with essential (n = 56) or renovascular (n = 40) hypertension were prospectively studied in controlled conditions (involving sodium intake and renin-angiotensin blockade). Single-kidney perfusion, volume, and GFR were measured by using multidetector CT time-attenuation curves and were compared with GFR measured by using iothalamate clearance, as assigned to the right and left kidney according to relative volumes. The reproducibility of CT GFR over a 3-month period (n = 21) was assessed in patients with renal artery stenosis who were undergoing stable medical treatment. Statistical analysis included the t test, Wilcoxon signed rank test, linear regression, and Bland-Altman analysis. Results CT GFR values were similar to those of iothalamate clearance (mean ± standard deviation, 38.2 mL/min ± 18 vs 41.6 mL/min ± 17; P = .062). Stenotic kidney CT GFR in patients with renal artery stenosis was lower than contralateral kidney GFR or essential hypertension single-kidney GFR (mean, 23.1 mL/min ± 13 vs 36.9 mL/min ± 17 [P = .0008] and 45.2 mL/min ± 16 [P = .019], respectively), as was iothalamate clearance (mean, 26.9 mL/min ± 14 vs 38.5 mL/min ± 15 [P = .0004] and 49.0 mL/min ± 14 [P = .001], respectively). CT GFR correlated well with iothalamate GFR (linear regression, CT GFR = 0.88*iothalamate GFR, r2 = 0.89, P < .0001), and Bland-Altman analysis was used to confirm the agreement. CT GFR was also moderately reproducible in medically treated patients with renal artery stenosis (concordance coefficient correlation, 0.835) but was unaffected by revascularization (mean, 25.3 mL/min ± 15.2 vs 30.3 mL/min ± 18.5; P = .097). Conclusion CT assessments of single-kidney GFR are reproducible and agree well with a reference standard. CT can be useful to obtain minimally invasive estimates of bilateral single-kidney function in human subjects. © RSNA, 2015 PMID:25848903
Robust extraction of the aorta and pulmonary artery from 3D MDCT image data
NASA Astrophysics Data System (ADS)
Taeprasartsit, Pinyo; Higgins, William E.
2010-03-01
Accurate definition of the aorta and pulmonary artery from three-dimensional (3D) multi-detector CT (MDCT) images is important for pulmonary applications. This work presents robust methods for defining the aorta and pulmonary artery in the central chest. The methods work on both contrast enhanced and no-contrast 3D MDCT image data. The automatic methods use a common approach employing model fitting and selection and adaptive refinement. During the occasional event that more precise vascular extraction is desired or the method fails, we also have an alternate semi-automatic fail-safe method. The semi-automatic method extracts the vasculature by extending the medial axes into a user-guided direction. A ground-truth study over a series of 40 human 3D MDCT images demonstrates the efficacy, accuracy, robustness, and efficiency of the methods.
Konietzke, Philip; Weinheimer, Oliver; Wielpütz, Mark O; Savage, Dasha; Ziyeh, Tiglath; Tu, Christin; Newman, Beverly; Galbán, Craig J; Mall, Marcus A; Kauczor, Hans-Ulrich; Robinson, Terry E
2018-01-01
Densitometry on paired inspiratory and expiratory multidetector computed tomography (MDCT) for the quantification of air trapping is an important approach to assess functional changes in airways diseases such as cystic fibrosis (CF). For a regional analysis of functional deficits, an accurate lobe segmentation algorithm applicable to inspiratory and expiratory scans is beneficial. We developed a fully automated lobe segmentation algorithm, and subsequently validated automatically generated lobe masks (ALM) against manually corrected lobe masks (MLM). Paired inspiratory and expiratory CTs from 16 children with CF (mean age 11.1±2.4) acquired at 4 time-points (baseline, 3mon, 12mon, 24mon) with 2 kernels (B30f, B60f) were segmented, resulting in 256 ALM. After manual correction spatial overlap (Dice index) and mean differences in lung volume and air trapping were calculated for ALM vs. MLM. The mean overlap calculated with Dice index between ALM and MLM was 0.98±0.02 on inspiratory, and 0.86±0.07 on expiratory CT. If 6 lobes were segmented (lingula treated as separate lobe), the mean overlap was 0.97±0.02 on inspiratory, and 0.83±0.08 on expiratory CT. The mean differences in lobar volumes calculated in accordance with the approach of Bland and Altman were generally low, ranging on inspiratory CT from 5.7±52.23cm3 for the right upper lobe to 17.41±14.92cm3 for the right lower lobe. Higher differences were noted on expiratory CT. The mean differences for air trapping were even lower, ranging from 0±0.01 for the right upper lobe to 0.03±0.03 for the left lower lobe. Automatic lobe segmentation delivers excellent results for inspiratory and good results for expiratory CT. It may become an important component for lobe-based quantification of functional deficits in cystic fibrosis lung disease, reducing necessity for user-interaction in CT post-processing.
Objective performance assessment of five computed tomography iterative reconstruction algorithms.
Omotayo, Azeez; Elbakri, Idris
2016-11-22
Iterative algorithms are gaining clinical acceptance in CT. We performed objective phantom-based image quality evaluation of five commercial iterative reconstruction algorithms available on four different multi-detector CT (MDCT) scanners at different dose levels as well as the conventional filtered back-projection (FBP) reconstruction. Using the Catphan500 phantom, we evaluated image noise, contrast-to-noise ratio (CNR), modulation transfer function (MTF) and noise-power spectrum (NPS). The algorithms were evaluated over a CTDIvol range of 0.75-18.7 mGy on four major MDCT scanners: GE DiscoveryCT750HD (algorithms: ASIR™ and VEO™); Siemens Somatom Definition AS+ (algorithm: SAFIRE™); Toshiba Aquilion64 (algorithm: AIDR3D™); and Philips Ingenuity iCT256 (algorithm: iDose4™). Images were reconstructed using FBP and the respective iterative algorithms on the four scanners. Use of iterative algorithms decreased image noise and increased CNR, relative to FBP. In the dose range of 1.3-1.5 mGy, noise reduction using iterative algorithms was in the range of 11%-51% on GE DiscoveryCT750HD, 10%-52% on Siemens Somatom Definition AS+, 49%-62% on Toshiba Aquilion64, and 13%-44% on Philips Ingenuity iCT256. The corresponding CNR increase was in the range 11%-105% on GE, 11%-106% on Siemens, 85%-145% on Toshiba and 13%-77% on Philips respectively. Most algorithms did not affect the MTF, except for VEO™ which produced an increase in the limiting resolution of up to 30%. A shift in the peak of the NPS curve towards lower frequencies and a decrease in NPS amplitude were obtained with all iterative algorithms. VEO™ required long reconstruction times, while all other algorithms produced reconstructions in real time. Compared to FBP, iterative algorithms reduced image noise and increased CNR. The iterative algorithms available on different scanners achieved different levels of noise reduction and CNR increase while spatial resolution improvements were obtained only with VEO™. This study is useful in that it provides performance assessment of the iterative algorithms available from several mainstream CT manufacturers.
Fuld, Matthew K.; Grout, Randall; Guo, Junfeng; Morgan, John H.; Hoffman, Eric A.
2013-01-01
Rationale and Objectives Multidetector-row Computed Tomography (MDCT) has emerged as a tool for quantitative assessment of parenchymal destruction, air trapping (density metrics) and airway remodeling (metrics relating airway wall and lumen geometry) in chronic obstructive pulmonary disease (COPD) and asthma. Critical to the accuracy and interpretability of these MDCT-derived metrics is the assurance that the lungs are scanned during a breath-hold at a standardized volume. Materials and Methods A computer monitored turbine-based flow meter system was developed to control patient breath-holds and facilitate static imaging at fixed percentages of the vital capacity. Due to calibration challenges with gas density changes during multi-breath xenon-CT an alternative system was required. The design incorporated dual rolling seal pistons. Both systems were tested in a laboratory environment and human subject trials. Results The turbine-based system successfully controlled lung volumes in 32/37 subjects, having a linear relationship for CT measured air volume between repeated scans: for all scans, the mean and confidence interval of the differences (scan1-scan2) was −9 ml (−169, 151); for TLC alone 6 ml (−164, 177); for FRC alone, −23 ml (−172, 126). The dual-piston system successfully controlled lung volume in 31/41 subjects. Study failures related largely to subject non-compliance with verbal instruction and gas leaks around the mouthpiece. Conclusion We demonstrate the successful use of a turbine-based system for static lung volume control and demonstrate its inadequacies for dynamic xenon-CT studies. Implementation of a dual-rolling seal spirometer has been shown to adequately control lung volume for multi-breath wash-in xenon-CT studies. These systems coupled with proper patient coaching provide the tools for the use of CT to quantitate regional lung structure and function. The wash-in xenon-CT method for assessing regional lung function, while not necessarily practical for routine clinical studies, provides for a dynamic protocol against which newly emerging single breath, dual-energy xenon-CT measures can be validated. PMID:22555001
Fuld, Matthew K; Grout, Randall W; Guo, Junfeng; Morgan, John H; Hoffman, Eric A
2012-08-01
Multidetector-row computed tomography (MDCT) has emerged as a tool for quantitative assessment of parenchymal destruction, air trapping (density metrics), and airway remodeling (metrics relating airway wall and lumen geometry) in chronic obstructive pulmonary disease (COPD) and asthma. Critical to the accuracy and interpretability of these MDCT-derived metrics is the assurance that the lungs are scanned during a breathhold at a standardized volume. A computer monitored turbine-based flow meter system was developed to control patient breathholds and facilitate static imaging at fixed percentages of the vital capacity. Because of calibration challenges with gas density changes during multibreath xenon CT, an alternative system was required. The design incorporated dual rolling seal pistons. Both systems were tested in a laboratory environment and human subject trials. The turbine-based system successfully controlled lung volumes in 32/37 subjects, having a linear relationship for CT measured air volume between repeated scans: for all scans, the mean and confidence interval of the differences (scan1-scan2) was -9 mL (-169, 151); for total lung capacity alone 6 mL (-164, 177); for functional residual capacity alone, -23 mL (-172, 126). The dual-piston system successfully controlled lung volume in 31/41 subjects. Study failures related largely to subject noncompliance with verbal instruction and gas leaks around the mouthpiece. We demonstrate the successful use of a turbine-based system for static lung volume control and demonstrate its inadequacies for dynamic xenon CT studies. Implementation of a dual-rolling seal spirometer has been shown to adequately control lung volume for multibreath wash-in xenon CT studies. These systems coupled with proper patient coaching provide the tools for the use of CT to quantitate regional lung structure and function. The wash-in xenon CT method for assessing regional lung function, although not necessarily practical for routine clinical studies, provides for a dynamic protocol against which newly emerging single breath, dual-energy xenon CT measures can be validated. Copyright © 2012 AUR. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arbique, G; Anderson, J; Guild, J
Purpose: The National Lung Screening Trial mandated manual low dose CT technique factors, where up to a doubling of radiation output could be used over a regular to large patient size range. Recent guidance from the AAPM and ACR for lung cancer CT screening recommends radiation output adjustment for patient size either through AEC or a manual technique chart. This study evaluated the use of AEC for output control and dose reduction. Methods: The study was performed on a multidetector helical CT scanner (Aquillion ONE, Toshiba Medical) equipped with iterative reconstruction (ADIR-3D), AEC was adjusted with a standard deviation (SD)more » image quality noise index. The protocol SD parameter was incrementally increased to reduce patient population dose while image quality was evaluated by radiologist readers scoring the clinical utility of images on a Likert scale. Results: Plots of effective dose vs. body size (water cylinder diameter reported by the scanner) demonstrate monotonic increase in patient dose with increasing patient size. At the initial SD setting of 19 the average CTDIvol for a standard size patient was ∼ 2.0 mGy (1.2 mSv effective dose). This was reduced to ∼1.0 mGy (0.5 mSv) at an SD of 25 with no noticeable reduction in clinical utility of images as demonstrated by Likert scoring. Plots of effective patient diameter and BMI vs body size indicate that these metrics could also be used for manual technique charts. Conclusion: AEC offered consistent and reliable control of radiation output in this study. Dose for a standard size patient was reduced to one-third of the 3 mGy CTDIvol limit required for ACR accreditation of lung cancer CT screening. Gary Arbique: Research Grant, Toshiba America Medical Systems; Cecelia Brewington: Research Grant, Toshiba America Medical Systems; Di Zhang: Employee, Toshiba America Medical Systems.« less
Di Mauro, R; Greco, L; Melis, M; Manenti, G; Floris, R; Giacomini, P G; Di Girolamo, M; Di Girolamo, S
2016-05-01
Beta thalassemia is a blood dyscrasia that caused a marked expansion of active marrow spaces and extramedullary haematopoiesis results. In these patients various alterations and abnormalities affects different body areas, including increased risk of sinusitis. The marrow expansion in the facial bones results in delay in pneumatisation of the sinuses, overgrowth of the maxillae, and forward displacement of the upper incisors with skeletal deformities. In current literature, maxillary sinuses are not deeply evaluated by CT scan studies in these kind of patients. The aim of our study was to investigate the presence of maxillary sinuses abnormalities by the use of CT in patients with beta-thalassemia major and to compare these findings with a control group free from this disease. A retrospective analysis of 22 paediatric patients with beta-thalassemia major and 22 control subjects without sinonasal diseases was performed. CT was done using a 64-multidetector-row CT scanner without contrast injection, obtained in axial plane using thin-slice technique. Evaluated parameters were: bone thickness of the lateral and anterior wall, density and volume of the maxillary sinuses. Significant difference was found between the study group and control group in the evaluation of all the parameters examined. The maxillary sinus of β thalassemic patients was smaller respect of controls, the bone was more dense and thick in the side and anterior wall. Beta-thalassemic patients have a relative risk of 2.87 to develop a maxillary sinusitis. In these patients there is an increased incidence of sinonasal infections due to the abnormal development of cranio facial skeleton. These bone alterations might confuse the physicians and lead to an increased rate of sinusitis diagnoses. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Guggenberger, Roman; Ulbrich, Erika J; Dietrich, Tobias J; Scholz, Rosemarie; Kaelin, Pascal; Köhler, Christoph; Elsässer, Thilo; Le Corroller, Thomas; Pfammatter, Thomas; Alkadhi, Hatem; Andreisek, Gustav
2017-02-01
To investigate radiation dose and diagnostic performance of C-arm flat-panel CT (FPCT) versus standard multi-detector CT (MDCT) shoulder arthrography using MRI-arthrography as reference standard. Radiation dose of two different FPCT acquisitions (5 and 20 s) and standard MDCT of the shoulder were assessed using phantoms and thermoluminescence dosimetry. FPCT arthrographies were performed in 34 patients (mean age 44 ± 15 years). Different joint structures were quantitatively and qualitatively assessed by two independent radiologists. Inter-reader agreement and diagnostic performance were calculated. Effective radiation dose was markedly lower in FPCT 5 s (0.6 mSv) compared to MDCT (1.7 mSv) and FPCT 20 s (3.4 mSv). Contrast-to-noise ratios (CNRs) were significantly (p < 0.05) higher in FPCT 20-s versus 5-s protocols. Inter-reader agreements of qualitative ratings ranged between к = 0.47-1.0. Sensitivities for cartilage and rotator cuff pathologies were low for FPCT 5-s (40 % and 20 %) and moderate for FPCT 20-s protocols (75 % and 73 %). FPCT showed high sensitivity (81-86 % and 89-99 %) for bone and acromioclavicular-joint pathologies. Using a 5-s protocol FPCT shoulder arthrography provides lower radiation dose compared to MDCT but poor sensitivity for cartilage and rotator cuff pathologies. FPCT 20-s protocol is moderately sensitive for cartilage and rotator cuff tendon pathology with markedly higher radiation dose compared to MDCT. • FPCT shoulder arthrography is feasible with fluoroscopy and CT in one workflow. • A 5-s FPCT protocol applies a lower radiation dose than MDCT. • A 20-s FPCT protocol is moderately sensitive for cartilage and tendon pathology.
NASA Astrophysics Data System (ADS)
Fahmi, Rachid; Eck, Brendan L.; Vembar, Mani; Bezerra, Hiram G.; Wilson, David L.
2014-03-01
We investigated the use of an advanced hybrid iterative reconstruction (IR) technique (iDose4, Philips Health- care) for low dose dynamic myocardial CT perfusion (CTP) imaging. A porcine model was created to mimic coronary stenosis through partial occlusion of the left anterior descending (LAD) artery with a balloon catheter. The severity of LAD occlusion was adjusted with FFR measurements. Dynamic CT images were acquired at end-systole (45% R-R) using a multi-detector CT (MDCT) scanner. Various corrections were applied to the acquired scans to reduce motion and imaging artifacts. Absolute myocardial blood flow (MBF) was computed with a deconvolution-based approach using singular value decomposition (SVD). We compared a high and a low dose radiation protocol corresponding to two different tube-voltage/tube-current combinations (80kV p/100mAs and 120kV p/150mAs). The corresponding radiation doses for these protocols are 7.8mSv and 34.3mSV , respectively. The images were reconstructed using conventional FBP and three noise-reduction strengths of the IR method, iDose. Flow contrast-to-noise ratio, CNRf, as obtained from MBF maps, was used to quantitatively evaluate the effect of reconstruction on contrast between normal and ischemic myocardial tissue. Preliminary results showed that the use of iDose to reconstruct low dose images provide better or comparable CNRf to that of high dose images reconstructed with FBP, suggesting significant dose savings. CNRf was improved with the three used levels of iDose compared to FBP for both protocols. When using the entire 4D dynamic sequence for MBF computation, a 77% dose reduction was achieved, while considering only half the scans (i.e., every other heart cycle) allowed even further dose reduction while maintaining relatively higher CNRf.
Telegrafo, Michele; Carluccio, Davide Antonio; Rella, Leonarda; Ianora, Amato Antonio Stabile; Angelelli, Giuseppe; Moschetta, Marco
2016-01-01
Purpose: To evaluate the role of multidetector computed tomography (MDCT) in recognizing the complications of extracorporeal shock wave lithotripsy (ESWL) and providing a prognostic grading system for the therapeutic approach. Materials and Methods: A total of 43 patients who underwent ESWL because of urinary stone disease were assessed by 320-row MDCT examination before and after ESWL. Pre-ESWL CT unenhanced scans were performed for diagnosing stone disease. Post-ESWL CT scans were acquired before and after intravenous injection of contrast medium searching for peri-renal fluid collection or hyper-density, pyelic or ureteral wall thickening, blood clots in the urinary tract, peri- or intra-renal hematoma or abscess, active bleeding. A severity grading system of ESWL complications was established. Results: Patients were affected by renal (n = 36) or ureteral (n = 7) lithiasis. Post-ESWL CT examination detected small fluid collections and hyper-density of peri-renal fat tissue in 35/43 patients (81%), pyelic or ureteral wall thickening in 2/43 (4%), blood clots in the urinary tract in 9/43 (21%), renal abscesses or hematomas with a diameter of <2 cm in 10/43 (23%), large retroperitoneal collections in 3/43 (7%), active bleeding from renal vessels in 1/43 (2%). Mild complications were found in 30 cases; moderate in 9; severe in 4. The therapeutic choice was represented by clinical follow-up (n = 20), clinical and CT follow-up (n = 10), ureteral stenting (n = 9), drainage of large retroperitoneal collections (n = 3), and arterial embolization (n = 1). Conclusion: MDCT plays a crucial role in the diagnosis of urolithiasis and follow-up of patients treated with ESWL recognizing its complications and providing therapeutic and prognostic indications. PMID:27141186
Telegrafo, Michele; Carluccio, Davide Antonio; Rella, Leonarda; Ianora, Amato Antonio Stabile; Angelelli, Giuseppe; Moschetta, Marco
2016-01-01
To evaluate the role of multidetector computed tomography (MDCT) in recognizing the complications of extracorporeal shock wave lithotripsy (ESWL) and providing a prognostic grading system for the therapeutic approach. A total of 43 patients who underwent ESWL because of urinary stone disease were assessed by 320-row MDCT examination before and after ESWL. Pre-ESWL CT unenhanced scans were performed for diagnosing stone disease. Post-ESWL CT scans were acquired before and after intravenous injection of contrast medium searching for peri-renal fluid collection or hyper-density, pyelic or ureteral wall thickening, blood clots in the urinary tract, peri- or intra-renal hematoma or abscess, active bleeding. A severity grading system of ESWL complications was established. Patients were affected by renal (n = 36) or ureteral (n = 7) lithiasis. Post-ESWL CT examination detected small fluid collections and hyper-density of peri-renal fat tissue in 35/43 patients (81%), pyelic or ureteral wall thickening in 2/43 (4%), blood clots in the urinary tract in 9/43 (21%), renal abscesses or hematomas with a diameter of <2 cm in 10/43 (23%), large retroperitoneal collections in 3/43 (7%), active bleeding from renal vessels in 1/43 (2%). Mild complications were found in 30 cases; moderate in 9; severe in 4. The therapeutic choice was represented by clinical follow-up (n = 20), clinical and CT follow-up (n = 10), ureteral stenting (n = 9), drainage of large retroperitoneal collections (n = 3), and arterial embolization (n = 1). MDCT plays a crucial role in the diagnosis of urolithiasis and follow-up of patients treated with ESWL recognizing its complications and providing therapeutic and prognostic indications.
Radiation dose management in thoracic CT: an international survey.
Molinari, Francesco; Tack, Denis M; Boiselle, Philip; Ngo, Long; Mueller-Mang, Christina; Litmanovich, Diana; Bankier, Alexander A
2013-01-01
We aimed to examine current practice patterns of international thoracic radiologists regarding radiation dose management in adult thoracic computed tomography (CT) examinations. An electronic questionnaire was sent to 800 members of five thoracic radiology societies in North America, Europe, Asia, and Latin America addressing radiation dose training and education, standard kVp and mAs settings for thoracic CT, dose reduction practices, clinical scenarios, and demographics. Of the 800 radiologists, 146 responded to our survey. Nearly half (66/146, 45% [95% confidence interval, 37%-53%]) had no formal training in dose reduction, with "self-study of the literature" being the most common form of training (54/146, 37% [29%-45%]). One hundred and seventeen (80% [74%-87%]) had automatic exposure control, and 76 (65% [56%-74%]) used it in all patients. Notably, most respondents (89% [84%-94%]) used a 120 to 125 kVp standard setting, whereas none used 140 kVp. The most common average dose-length-product (DLP) value was 150 to 249 mGy.cm (75/146, 51% [43%-59%]), and 59% (51%-67%) delivered less than 250 mGy.cm in a 70 kg patient. There was a tendency towards higher DLP values with multidetector-row CT. Age, gender, and pregnancy were associated more with dose reduction than weight and clinical indication. Efforts for reducing patient radiation dose are highly prevalent among thoracic radiologists. Areas for improvement include reduction of default tube current settings, reduction of anatomical scan coverage, greater use of automatic exposure control, and eventually, reduction of current reference dose values. Our study emphasizes the need for international guidelines to foster greater conformity in dose reduction by thoracic radiologists.
Sarikaya, B; Lohman, B; Mckinney, A M; Gadani, S; Irfan, M; Lucato, L
2012-01-01
Objectives Previous evidence supports a direct relationship between the calcium burden (volume) on post-contrast CT with the percent internal carotid artery (ICA) stenosis at the carotid bifurcation. We sought to further investigate this relationship by comparing non-enhanced CT (NECT) and digital subtraction angiography (DSA). Methods 50 patients (aged 41–82 years) were retrospectively identified who had undergone cervical NECT and DSA. A 64-multidetector array CT (MDCT) scanner was utilised and the images reviewed using preset window widths/levels (30/300) optimised to calcium, with the volumes measured via three-dimensional reconstructive software. Stenosis measurements were performed on DSA and luminal diameter stenoses >40% were considered “significant”. Volume thresholds of 0.01, 0.03, 0.06, 0.09 and 0.12 cm3 were utilised and Pearson'S correlation coefficient (r) was calculated to correlate the calcium volume with percent stenosis. Results Of 100 carotid bifurcations, 88 were available and of these 7 were significantly stenotic. The NECT calcium volume moderately correlated with percent stenosis on DSA r=0.53 (p<0.01). A moderate–strong correlation was found between the square root of calcium volume on NECT with percent stenosis on DSA (r=0.60, p<0.01). Via a receiver operating characteristic curve, 0.06 cm3 was determined to be the best threshold (sensitivity 100%, specificity 90.1%, negative predictive value 100% and positive predictive value 46.7%) for detecting significant stenoses. Conclusion This preliminary investigation confirms a correlation between carotid bifurcation calcium volume and percent ICA stenosis and is promising for the optimal threshold for stenosis detection. Future studies could utilise calcium volumes to create a “score” that could predict high grade stenosis. PMID:21896662
NASA Astrophysics Data System (ADS)
Chiarot, C. B.; Siewerdsen, J. H.; Haycocks, T.; Moseley, D. J.; Jaffray, D. A.
2005-11-01
Development, characterization, and quality assurance of advanced x-ray imaging technologies require phantoms that are quantitative and well suited to such modalities. This note reports on the design, construction, and use of an innovative phantom developed for advanced imaging technologies (e.g., multi-detector CT and the numerous applications of flat-panel detectors in dual-energy imaging, tomosynthesis, and cone-beam CT) in diagnostic and image-guided procedures. The design addresses shortcomings of existing phantoms by incorporating criteria satisfied by no other single phantom: (1) inserts are fully 3D—spherically symmetric rather than cylindrical; (2) modules are quantitative, presenting objects of known size and contrast for quality assurance and image quality investigation; (3) features are incorporated in ideal and semi-realistic (anthropomorphic) contexts; and (4) the phantom allows devices to be inserted and manipulated in an accessible module (right lung). The phantom consists of five primary modules: (1) head, featuring contrast-detail spheres approximate to brain lesions; (2) left lung, featuring contrast-detail spheres approximate to lung modules; (3) right lung, an accessible hull in which devices may be placed and manipulated; (4) liver, featuring conrast-detail spheres approximate to metastases; and (5) abdomen/pelvis, featuring simulated kidneys, colon, rectum, bladder, and prostate. The phantom represents a two-fold evolution in design philosophy—from 2D (cylindrically symmetric) to fully 3D, and from exclusively qualitative or quantitative to a design accommodating quantitative study within an anatomical context. It has proven a valuable tool in investigations throughout our institution, including low-dose CT, dual-energy radiography, and cone-beam CT for image-guided radiation therapy and surgery.
Chen, Jiang-Hong; Jin, Er-Hu; He, Wen; Zhao, Li-Qin
2014-01-01
Objective To reduce radiation dose while maintaining image quality in low-dose chest computed tomography (CT) by combining adaptive statistical iterative reconstruction (ASIR) and automatic tube current modulation (ATCM). Methods Patients undergoing cancer screening (n = 200) were subjected to 64-slice multidetector chest CT scanning with ASIR and ATCM. Patients were divided into groups 1, 2, 3, and 4 (n = 50 each), with a noise index (NI) of 15, 20, 30, and 40, respectively. Each image set was reconstructed with 4 ASIR levels (0% ASIR, 30% ASIR, 50% ASIR, and 80% ASIR) in each group. Two radiologists assessed subjective image noise, image artifacts, and visibility of the anatomical structures. Objective image noise and signal-to-noise ratio (SNR) were measured, and effective dose (ED) was recorded. Results Increased NI was associated with increased subjective and objective image noise results (P<0.001), and SNR decreased with increasing NI (P<0.001). These values improved with increased ASIR levels (P<0.001). Images from all 4 groups were clinically diagnosable. Images with NI = 30 and 50% ASIR had average subjective image noise scores and nearly average anatomical structure visibility scores, with a mean objective image noise of 23.42 HU. The EDs for groups 1, 2, 3 and 4 were 2.79±1.17, 1.69±0.59, 0.74±0.29, and 0.37±0.22 mSv, respectively. Compared to group 1 (NI = 15), the ED reductions were 39.43%, 73.48%, and 86.74% for groups 2, 3, and 4, respectively. Conclusions Using NI = 30 with 50% ASIR in the chest CT protocol, we obtained average or above-average image quality but a reduced ED. PMID:24691208
Chen, Jiang-Hong; Jin, Er-Hu; He, Wen; Zhao, Li-Qin
2014-01-01
To reduce radiation dose while maintaining image quality in low-dose chest computed tomography (CT) by combining adaptive statistical iterative reconstruction (ASIR) and automatic tube current modulation (ATCM). Patients undergoing cancer screening (n = 200) were subjected to 64-slice multidetector chest CT scanning with ASIR and ATCM. Patients were divided into groups 1, 2, 3, and 4 (n = 50 each), with a noise index (NI) of 15, 20, 30, and 40, respectively. Each image set was reconstructed with 4 ASIR levels (0% ASIR, 30% ASIR, 50% ASIR, and 80% ASIR) in each group. Two radiologists assessed subjective image noise, image artifacts, and visibility of the anatomical structures. Objective image noise and signal-to-noise ratio (SNR) were measured, and effective dose (ED) was recorded. Increased NI was associated with increased subjective and objective image noise results (P<0.001), and SNR decreased with increasing NI (P<0.001). These values improved with increased ASIR levels (P<0.001). Images from all 4 groups were clinically diagnosable. Images with NI = 30 and 50% ASIR had average subjective image noise scores and nearly average anatomical structure visibility scores, with a mean objective image noise of 23.42 HU. The EDs for groups 1, 2, 3 and 4 were 2.79 ± 1.17, 1.69 ± 0.59, 0.74 ± 0.29, and 0.37 ± 0.22 mSv, respectively. Compared to group 1 (NI = 15), the ED reductions were 39.43%, 73.48%, and 86.74% for groups 2, 3, and 4, respectively. Using NI = 30 with 50% ASIR in the chest CT protocol, we obtained average or above-average image quality but a reduced ED.
Koshkelashvili, Nikoloz; Codolosa, Jose N; Goykhman, Igor; Romero-Corral, Abel; Pressman, Gregg S
2015-12-15
Aging is associated with calcium deposits in various cardiovascular structures, but patterns of calcium deposition, if any, are unknown. In search of such patterns, we performed quantitative assessment of mitral annular calcium (MAC) and aortic valve calcium (AVC) in a broad clinical sample. Templates were created from gated computed tomography (CT) scans depicting the aortic valve cusps and mitral annular segments in relation to surrounding structures. These were then applied to CT reconstructions from ungated, clinically indicated CT scans of 318 subjects, aged ≥65 years. Calcium location was assigned using the templates and quantified by the Agatston method. Mean age was 76 ± 7.3 years; 48% were men and 58% were white. Whites had higher prevalence (p = 0.03) and density of AVC than blacks (p = 0.02), and a trend toward increased MAC (p = 0.06). Prevalence of AVC was similar between men and women, but AVC scores were higher in men (p = 0.008); this difference was entirely accounted for by whites. Within the aortic valve, the left cusp was more frequently calcified than the others. MAC was most common in the posterior mitral annulus, especially its middle (P2) segment. For the anterior mitral annulus, the medial (A3) segment calcified most often. In conclusion, AVC is more common in whites than blacks, and more intense in men, but only in whites. Furthermore, calcium deposits in the mitral annulus and aortic valve favor certain locations. Copyright © 2015 Elsevier Inc. All rights reserved.
Inokuchi, Go; Yajima, Daisuke; Hayakawa, Mutsumi; Motomura, Ayumi; Chiba, Fumiko; Torimitsu, Suguru; Makino, Yohsuke; Iwase, Hirotaro
2013-12-01
Historically, coronary angiography of the isolated heart has played an important role in the detection of stenotic or occlusive lesions that are difficult to identify by autopsy alone. Meanwhile, although the application of multidetector computed tomography (MDCT) to forensic fields has accelerated recently, isolated single organ angiography with MDCT is rarely performed. In this article, we present an evaluation of postmortem selective coronary CT angiography of the isolated heart with MDCT and discuss its utility for autopsy. First, in a preliminary experiment using pig coronary artery, we examined the behavior of water soluble contrast material on postmortem computed tomography angiography (PMCTA) and found that better angiographic images were acquired when the viscosity of the contrast material was increased and CT was performed under conditions of sustained perfusion. Based on these results, we devised a selective coronary angiography procedure using a pressurized bag for drip infusion that can be performed easily, quickly, and at low cost. The angiographic images obtained provided useful supportive evidence of autopsy findings suggestive of ischemic heart disease. With active discussions underway in forensic fields on the proper use of postmortem computed tomography, PMCTA has also naturally attracted attention as it compensates for some of the shortcomings of CT alone. Although PMCTA typically involves whole-body angiography, if we view PMCTA as one of the many useful and supplementary tools available for autopsy, then isolated heart angiography continues to have utility in autopsy today.
Lou, Junyang; Obuchowski, Nancy A; Krishnaswamy, Amar; Popovic, Zoran; Flamm, Scott D; Kapadia, Samir R; Svensson, Lars G; Bolen, Michael A; Desai, Milind Y; Halliburton, Sandra S; Tuzcu, E Murat; Schoenhagen, Paul
2015-01-01
Preprocedural 3-dimensional CT imaging of the aortic annular plane plays a critical role for transcatheter aortic valve replacement (TAVR) planning; however, manual reconstructions are complex. Automated analysis software may improve reproducibility and agreement between readers but is incompletely validated. In 110 TAVR patients (mean age, 81 years; 37% female) undergoing preprocedural multidetector CT, automated reconstruction of the aortic annular plane and planimetry of the annulus was performed with a prototype of now commercially available software (syngo.CT Cardiac Function-Valve Pilot; Siemens Healthcare, Erlangen, Germany). Fully automated, semiautomated, and manual annulus measurements were compared. Intrareader and inter-reader agreement, intermodality agreement, and interchangeability were analyzed. Finally, the impact of these measurements on recommended valve size was evaluated. Semiautomated analysis required major correction in 5 patients (4.5%). In the remaining 95.5%, only minor correction was performed. Mean manual annulus area was significantly smaller than fully automated results (P < .001 for both readers) but similar to semiautomated measurements (5.0 vs 5.4 vs 4.9 cm(2), respectively). The frequency of concordant recommendations for valve size increased if manual analysis was replaced with the semiautomated method (60% agreement was improved to 82.4%; 95% confidence interval for the difference [69.1%-83.4%]). Semiautomated aortic annulus analysis, with minor correction by the user, provides reliable results in the context of TAVR annulus evaluation. Copyright © 2015 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.
Sakamoto, Takashi; Mitsuzaki, Katsuhiko; Utsunomiya, Daisuke; Matsuda, Katsuhiko; Yamamura, Sadahiro; Urata, Joji; Kawakami, Megumi; Yamashita, Yasuyuki
2012-09-01
Although the screening of small, flat polyps is clinically important, the role of CT colonography (CTC) screening in their detection has not been thoroughly investigated. To evaluate the detection capability and usefulness of CTC in the screening of flat and polypoid lesions by comparing CTC with optic colonoscopy findings as the gold standard. We evaluated the CTC detection capability for flat colorectal polyps with a flat surface and a height not exceeding 3 mm (n = 42) by comparing to conventional polypoid lesions (n = 418) according to the polyp diameter. Four types of reconstruction images including multiplanar reconstruction, volume rendering, virtual gross pathology, and virtual endoscopic images were used for visual analysis. We compared the abilities of the four reconstructions for polyp visualization. Detection sensitivity for flat polyps was 31.3%, 44.4%, and 87.5% for lesions measuring 2-3 mm, 4-5 mm, and ≥6 mm, respectively; the corresponding sensitivity for polypoid lesions was 47.6%, 79.0%, and 91.7%. The overall sensitivity for flat lesions (47.6%) was significantly lower than polypoid lesions (64.1%). Virtual endoscopic imaging showed best visualization among the four reconstructions. Colon cancers were detected in eight patients by optic colonoscopy, and CTC detected colon cancers in all eight patients. CTC using 64-row multidetector CT is useful for colon cancer screening to detect colorectal polyps while the detection of small, flat lesions is still challenging.
Andreini, Daniele; Pontone, Gianluca; Mushtaq, Saima; Gransar, Heidi; Conte, Edoardo; Bartorelli, Antonio L; Pepi, Mauro; Opolski, Maksymilian P; Ó Hartaigh, Bríain; Berman, Daniel S; Budoff, Matthew J; Achenbach, Stephan; Al-Mallah, Mouaz; Cademartiri, Filippo; Callister, Tracy Q; Chang, Hyuk-Jae; Chinnaiyan, Kavitha; Chow, Benjamin J W; Cury, Ricardo; Delago, Augustin; Hadamitzky, Martin; Hausleiter, Joerg; Feuchtner, Gudrun; Kim, Yong-Jin; Kaufmann, Philipp A; Leipsic, Jonathon; Lin, Fay Y; Maffei, Erica; Raff, Gilbert; Shaw, Leslee J; Villines, Todd C; Dunning, Allison; Marques, Hugo; Rubinshtein, Ronen; Hindoyan, Niree; Gomez, Millie; Min, James K
2017-03-15
Non-obstructive coronary artery disease (CAD) identified by coronary computed tomography angiography (CCTA) demonstrated prognostic value. CT-adapted Leaman score (CT-LeSc) showed to improve the prognostic stratification. Aim of the study was to evaluate the capability of CT-LeSc to assess long-term prognosis of patients with non-obstructive (CAD). From 17 centers, we enrolled 2402 patients without prior CAD history who underwent CCTA that showed non-obstructive CAD and provided complete information on plaque composition. Patients were divided into a group without CAD and a group with non-obstructive CAD (<50% stenosis). Segment-involvement score (SIS) and CT-LeSc were calculated. Outcomes were non-fatal myocardial infarction (MI) and the combined end-point of MI and all-cause mortality. Patient mean age was 56±12years. At follow-up (mean 59.8±13.9months), 183 events occurred (53 MI, 99 all-cause deaths and 31 late revascularizations). CT-LeSc was the only multivariate predictor of MI (HRs 2.84 and 2.98 in two models with Framingham and risk factors, respectively) and of MI plus all-cause mortality (HR 2.48 and 1.94 in two models with Framingham and risk factors, respectively). This was confirmed by a net reclassification analysis confirming that the CT-LeSc was able to correctly reclassify a significant proportion of patients (cNRI 0.28 and 0.23 for MI and MI plus all-cause mortality, respectively) vs. baseline model, whereas SIS did not. CT-LeSc is an independent predictor of major acute cardiac events, improving prognostic stratification of patients with non-obstructive CAD. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Gul, Enes Elvin; Can, Ilknur; Guler, Ibrahim; Yesildag, Ahmet; Abdulhalikov, Turyan; Kayrak, Mehmet; Ozdemir, Kurtulus; Gok, Hasan
2012-01-01
Heart-type fatty acid binding protein (H-FABP) is a sensitive marker of myocardial injury and predictor of worse prognosis in patients with pulmonary embolism (PE). Assessment of right ventricular dysfunction and pulmonary artery obstruction index (PAOI) with computed tomography (CT) has been reported as a predictor of mortality in PE. Therefore, we aimed to assess the correlation between H-FABP and CT angiographic PAOI in PE patients at intermediate risk. Sixty-one patients (28 males; mean age, 62 ± 17 years) with diagnosis of PE were included in this study. CT was performed in all patients, and the following parameters were evaluated: right ventricle/left ventricle ratio (RV/LV), pulmonary artery axial diameter, superior vena cava axial diameter, and PAOI determined with Qanadli score. Blood samples were assessed for H-FABP and troponin levels. Patients were followed for 30 days after discharge. Mean PAOI was 57 ± 18%. Eleven patients died during the follow-up period due to PE (18% mortality rate). H-FABP was positive in 21 patients (35%). There was no difference in CT parameters between patients with positive H-FABP and negative H-FABP. In addition, CT parameters were similar between patients who survived and those who did not. RV/LV ratio correlated with PAOI score. Among the biomarkers, troponin levels correlated with both RV/LV ratio and PAOI. H-FABP was an independent predictor of mortality. PAOI and RV/LV ratio did not predict 30-day mortality. Although H-FABP positivity confers a bad prognosis on PE patients at intermediate risk, PAOI did not predict mortality in this group.
Çiledağ, Nazan; Arda, Kemal; Arıbaş, Bilgin Kadri; Tekgündüz, Ali Irfan Emre; Altuntaş, Fevzi
2012-01-01
Objective: To evaluate vessel involvement and the role of multidetector computed tomography (MDCT) in the earlydiagnosis of invasive pulmonary aspergillosis (IPA) in patients with febrile neutropenia and antibiotic-resistant feverundergoing autologous bone morrow transplantation. Material and Methods: In all, 74 pulmonary MDCT examinations in 37 consecutive hematopoietic stem celltransplantation patients with febrile neutropenia and clinically suspected IPA were retrospectively evaluated. Results: Diagnosis of IPA was based on Fungal Infections Cooperative Group, and National Institute of Allergy andInfectious Diseases Mycoses Study Consensus Group criteria. In all, 0, 14, and 11 patients were diagnosed as proven,probable, and possible IPA, respectively. Among the 25 patients accepted as probable and possible IPA, all had pulmonaryMDCT findings consistent with IPA. The remaining 12 patients were accepted as having fever of unknown origin (FUO)and had patent vessels based on MDCT findings.In the patients with probable and possible IPA, 72 focal pulmonary lesions were observed; in 41 of the 72 (57%) lesionsvascular occlusion was noted and the CT halo sign was observed in 25 of these 41 (61%) lesions. Resolution of feveroccurred following antifungal therapy in 19 (76%) of the 25 patients with probable and possible IPA. In all, 6 (25%)of the patients diagnosed as IPA died during follow-up. Transplant-related mortality 100 d post transplant in patientswith IPA and FUO was 24% and 0%, respectively. Conclusion: In conclusion, MDCT has a potential role in the early diagnosis of IPA via detection of vessel occlusion. PMID:24744620
Ishii, Namiko; Sakuma, Ayaka; Makino, Yohsuke; Torimitsu, Suguru; Yajima, Daisuke; Inokuchi, Go; Motomura, Ayumi; Chiba, Fumiko; Hoshioka, Yumi; Iwase, Hirotaro; Saitoh, Hisako
2016-09-01
The purpose of this study was to determine the incidence of three-rooted mandibular first molars in a contemporary Japanese population using multidetector computed tomography (MDCT) and examine whether this characteristic root form may be useful for identification purposes. Prior to their forensic autopsies, we obtained MDCT scans of 365 cadavers (255 males, 110 females) with mandibular first molars on both sides. Altogether, 730 mandibular first molars were examined morphologically on reconstructed CT images, and the incidence of three-rooted molars was recorded. The results were analyzed statistically to determine sex and left-right differences using the chi-square test. In all, 189 (25.9%) of the 730 mandibular first molars had three roots: 79 (31.0%) in the 255 males and 35 (31.8%) in the 110 females. No statistically significant difference was found between the sexes. In the 39 individuals who had unilateral three-rooted mandibular first molars, 7 (17.9%) were on the left side and 32 (82.1%) were on the right side, indicating a statistically significant predominance on the right side. The incidence of three-rooted mandibular first molars in contemporary Japanese individuals was 25.9%, with no statistically significant sex difference, but in the case of unilateral three-rooted teeth, with a statistically significant predominance on the right side. Our study found that Japanese and northeastern Asians have a high incidence of the three-rooted mandibular first molars among individuals of Mongolian origin; this finding may be a useful screening tool for identification of unknown individuals. Copyright © 2016. Published by Elsevier Ireland Ltd.
Monte: A compact and versatile multidetector system based on monolithic telescopes
NASA Astrophysics Data System (ADS)
Amorini, F.; Bonanno, A.; Cardella, G.; di Pietro, A.; Fallica, G.; Figuera, P.; Morea, A.; Musumarra, A.; Papa, M.; Pappalardo, G.; Pinto, A.; Rizzo, F.; Tian, W.; Tudisco, S.; Valvo, G.
2005-09-01
We present the characteristics of a new multidetector based on monolithic silicon telescopes: MONTE. By using high-energy ion implantation techniques, the ΔE and residual energy stages of such telescopes have been integrated on the same silicon chip, obtaining extremely thin ΔE stages of the order of 1 μm. This allowed one to obtain a very low charge identification energy threshold and a very good β background suppression in reactions induced by radioactive ion beams. The multidetector has a modular structure and can be assembled in different geometrical configurations according to experimental needs.
WE-B-207-00: CT Lung Cancer Screening Part 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
2015-06-15
The US National Lung Screening Trial (NLST) was a multi-center randomized, controlled trial comparing a low-dose CT (LDCT) to posterior-anterior (PA) chest x-ray (CXR) in screening older, current and former heavy smokers for early detection of lung cancer. Recruitment was launched in September 2002 and ended in April 2004 when 53,454 participants had been randomized at 33 screening sites in equal proportions. Funded by the National Cancer Institute this trial demonstrated that LDCT screening reduced lung cancer mortality. The US Preventive Services Task Force (USPSTF) cited NLST findings and conclusions in its deliberations and analysis of lung cancer screening. Undermore » the 2010 Patient Protection and Affordable Care Act, the USPSTF favorable recommendation regarding lung cancer CT screening assisted in obtaining third-party payers coverage for screening. The objective of this session is to provide an introduction to the NLST and the trial findings, in addition to a comprehensive review of the dosimetry investigations and assessments completed using individual NLST participant CT and CXR examinations. Session presentations will review and discuss the findings of two independent assessments, a CXR assessment and the findings of a CT investigation calculating individual organ dosimetry values. The CXR assessment reviewed a total of 73,733 chest x-ray exams that were performed on 92 chest imaging systems of which 66,157 participant examinations were used. The CT organ dosimetry investigation collected scan parameters from 23,773 CT examinations; a subset of the 75,133 CT examinations performed using 97 multi-detector CT scanners. Organ dose conversion coefficients were calculated using a Monte Carlo code. An experimentally-validated CT scanner simulation was coupled with 193 adult hybrid computational phantoms representing the height and weight of the current U.S. population. The dose to selected organs was calculated using the organ dose library and the abstracted scan parameters. This session will review the results and summarize the individualized doses to major organs and the mean effective dose and CTDIvol estimate for 66,157 PA chest and 23,773 CT examinations respectively, using size-dependent computational phantoms coupled with Monte Carlo calculations. Learning Objectives: Review and summarize relevant NLST findings and conclusions. Understand the scope and scale of the NLST specific to participant dosimetry. Provide a comprehensive review of NLST participant dosimetry assessments. Summarize the results of an investigation providing individualized organ dose estimates for NLST participant cohorts.« less
Schwaiger, Benedikt J; Kopperdahl, David L; Nardo, Lorenzo; Facchetti, Luca; Gersing, Alexandra S; Neumann, Jan; Lee, Kwang J; Keaveny, Tony M; Link, Thomas M
2017-08-01
Bone fracture risk assessed ancillary to positron emission tomography with computed tomography co-registration (PET/CT) could provide substantial clinical value to oncology patients with elevated fracture risk without introducing additional radiation dose. The purpose of our study was to investigate the feasibility of obtaining valid measurements of bone mineral density (BMD) and finite element analysis-derived bone strength of the hip and spine using PET/CT examinations of prostate cancer patients by comparing against values obtained using routine multidetector-row computed tomography (MDCT) scans-as validated in previous studies-as a reference standard. Men with prostate cancer (n=82, 71.6±8.3 years) underwent Fluorine-18 NaF PET/CT and routine MDCT within three months. Femoral neck and total hip areal BMD, vertebral trabecular BMD and femur and vertebral strength based on finite element analysis were assessed in 63 paired PET/CT and MDCT examinations using phantomless calibration and Biomechanical-CT analysis. Men with osteoporosis or fragile bone strength identified at either the hip or spine (vertebral trabecular BMD ≤80mg/cm 3 , femoral neck or total hip T-score ≤-2.5, vertebral strength ≤6500N and femoral strength ≤3500N, respectively) were considered to be at high risk of fracture. PET/CT- versus MDCT-based BMD and strength measurements were compared using paired t-tests, linear regression and by generating Bland-Altman plots. Agreement in fracture-risk classification was assessed in a contingency table. All measurements from PET/CT versus MDCT were strongly correlated (R 2 =0.93-0.97; P<0.0001 for all). Mean differences for total hip areal BMD (0.001g/cm 2 , 1.1%), femoral strength (-60N, 1.3%), vertebral trabecular BMD (2mg/cm 3 , 2.6%) and vertebral strength (150N; 1.7%) measurements were not statistically significant (P>0.05 for all), whereas the mean difference in femoral neck areal BMD measurements was small but significant (-0.018g/cm 2 ; -2.5%; P=0.007). The agreement between PET/CT and MDCT for fracture-risk classification was 97% (0.89 kappa for repeatability). Ancillary analyses of BMD, bone strength, and fracture risk agreed well between PET/CT and MDCT, suggesting that PET/CT can be used opportunistically to comprehensively assess bone integrity. In subjects with high fracture risk such as cancer patients this may serve as an additional clinical tool to guide therapy planning and prevention of fractures. Copyright © 2017 Elsevier Inc. All rights reserved.
Benedetti, Nancy; Aslam, Rizwan; Wang, Zhen J.; Joe, Bonnie N.; Fu, Yanjun; Yee, Judy; Yeh, Benjamin M.
2010-01-01
OBJECTIVE The objective of our study was to determine the prevalence and clinical predictors of delayed contrast enhancement of ascites. MATERIALS AND METHODS In this retrospective study, 132 consecutive patients with ascites who underwent repeated abdominopelvic CT examinations performed within 7 days of each other were identified. These patients included 112 patients who received and 20 who did not receive IV contrast material at the initial CT examination. For each examination, we recorded the CT attenuation of the ascites. For the follow-up scan, the presence of delayed enhancement of ascites was defined as an increase in CT attenuation > 10 HU over baseline. The Fisher’s exact test, unpaired Student’s t test, and logistic regression were used to determine predictors of delayed enhancement of ascites. RESULTS A threshold increase in the attenuation of ascites by > 10 HU or more between the initial and follow-up CT examinations occurred only when IV contrast material was given with the initial examination. The increased attenuation was due to delayed contrast enhancement of ascites and occurred in 15 of the 112 patients (13%). Of the 16 patients scanned less than 1 day apart, 10 (63%) showed delayed enhancement of ascites. Delayed enhancement was not observed 3 or more days after IV contrast material administration. For each 1 mg/dL increase in serum creatinine level, the likelihood of delayed enhancement of ascites increased (odds ratio, 2.02; 95% CI, 1.11–3.69). Multivariate logistic regression showed that a short time interval between examinations (p < 0.001), increased serum creatinine level (p < 0.001), and presence of loculated ascites (p = < 0.01) were independent predictors of the magnitude of delayed enhancement of ascites. CONCLUSION Delayed contrast enhancement of ascites occurs commonly after recent prior IV contrast material administration and should not be mistaken for hemoperitoneum or proteinaceous fluid such as pus. PMID:19696286
Newell, John D; Fuld, Matthew K; Allmendinger, Thomas; Sieren, Jered P; Chan, Kung-Sik; Guo, Junfeng; Hoffman, Eric A
2015-01-01
The purpose of this study was to evaluate the impact of ultralow radiation dose single-energy computed tomographic (CT) acquisitions with Sn prefiltration and third-generation iterative reconstruction on density-based quantitative measures of growing interest in phenotyping pulmonary disease. The effects of both decreasing dose and different body habitus on the accuracy of the mean CT attenuation measurements and the level of image noise (SD) were evaluated using the COPDGene 2 test object, containing 8 different materials of interest ranging from air to acrylic and including various density foams. A third-generation dual-source multidetector CT scanner (Siemens SOMATOM FORCE; Siemens Healthcare AG, Erlangen, Germany) running advanced modeled iterative reconstruction (ADMIRE) software (Siemens Healthcare AG) was used.We used normal and very large body habitus rings at dose levels varying from 1.5 to 0.15 mGy using a spectral-shaped (0.6-mm Sn) tube output of 100 kV(p). Three CT scans were obtained at each dose level using both rings. Regions of interest for each material in the test object scans were automatically extracted. The Hounsfield unit values of each material using weighted filtered back projection (WFBP) at 1.5 mGy was used as the reference value to evaluate shifts in CT attenuation at lower dose levels using either WFBP or ADMIRE. Statistical analysis included basic statistics, Welch t tests, multivariable covariant model using the F test to assess the significance of the explanatory (independent) variables on the response (dependent) variable, and CT mean attenuation, in the multivariable covariant model including reconstruction method. Multivariable regression analysis of the mean CT attenuation values showed a significant difference with decreasing dose between ADMIRE and WFBP. The ADMIRE has reduced noise and more stable CT attenuation compared with WFBP. There was a strong effect on the mean CT attenuation values of the scanned materials for ring size (P < 0.0001) and dose level (P < 0.0001). The number of voxels in the region of interest for the particular material studied did not demonstrate a significant effect (P > 0.05). The SD was lower with ADMIRE compared with WFBP at all dose levels and ring sizes (P < 0.05). The third-generation dual-source CT scanners using third-generation iterative reconstruction methods can acquire accurate quantitative CT images with acceptable image noise at very low-dose levels (0.15 mGy). This opens up new diagnostic and research opportunities in CT phenotyping of the lung for developing new treatments and increased understanding of pulmonary disease.
Massaro, Peter Alexander; Kanji, Avinash; Atkinson, Paul; Pawsey, Ryan; Whelan, Tom
2017-01-01
Introduction Our objective was to determine whether unilateral calculus-induced ureteric obstruction on computed tomography (CT) was independently associated with the need for urological intervention and 30-day return to the emergency department (ED). Methods We performed a retrospective cohort study of patients with symptomatic urinary calculi diagnosed by unenhanced helical CT. Stepwise regression analysis was used to determine the predictors of urological intervention and 30-day return to the ED. Potential predictors assessed included: patient demographics, calculus size, calculus location, degree of obstruction, analgesic doses, signs and symptoms of infection, serum creatinine, cumulative intravenous fluid administered, and the prescription of medical expulsive therapy. Results Of 195 patients, 81 (41.5%) underwent urological intervention. The size of the calculus, its location, and the cumulative opioid dose were all independent predictors for urological intervention. Every 1 mm increase in calculus size increased the likelihood of intervention 2.2 times (odds ratio [OR] 2.17; 95% confidence interval [CI] 1.67–2.85). Proximal stones were 4.7 times more likely to require intervention than distal calculi (OR 0.21; 95% CI 0.09–0.49). Every 10 mg increase in morphine was associated with a 30% increase in the odds of intervention (OR 1.30; 95% CI 1.07–1.58). Degree of obstruction was not associated with the need for urological intervention. Finally, none of the variables were predictors for 30-day return to the ED. Conclusions Although stone size, proximal location, and severe pain, as indicated by higher opioid doses, were associated with the need for intervention, the degree of obstruction did not influence the management of patients with CT-defined urinary calculi. PMID:28515805
Borge, Finn-Magnus; Hoffart, Asle; Sexton, Harold; Martinsen, Egil; Gude, Tore; Hedley, Liv Margaret; Abrahamsen, Gun
2010-01-01
We examined changes in avoidant and dependent personality disorder dimensions, and pre-treatment and in-treatment factors associated with such changes in 77 patients, randomized to medication-free residential cognitive (CT) or residential interpersonal therapy for social phobia. Personality disorders and personality dimensions according to the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV) were assessed at pre-treatment and at one-year post-treatment. Both treatments were associated with a decrease in avoidant and dependent personality dimensions; dependent dimension decreased more in CT. Changes in cognitive factors predicted changes in both personality dimensions, whereas changes in symptoms or interpersonal factors did not. Change in the cognitive factor estimated cost was the most powerful predictor in the avoidant dimension, as it was the only predictor that remained significant in the forward regression analyses. Change in the cognitive factor estimated cost, and treatment were the most powerful predictors of change in the dependent dimension. Pre-treatment use of anxiolytics predicted larger changes in both PD dimensions.
Zhu, Ye-Hua; Wang, Xun; Zhang, Jin; Chen, Yong-Hui; Kong, Wen; Huang, Yi-Ran
2014-09-01
The purpose of this study was to assess the relation between tumor enhancement on multiphase contrast-enhanced CT images and Fuhrman grade of clear cell renal cell carcinoma. A single-institution retrospective review was conducted on the records of 255 patients who underwent radical or partial nephrectomy and received a histologic diagnosis of clear cell renal cell carcinoma. Two radiologists recorded the radiographic features of each patient, including the attenuation value of the lesion, lesion size, calcification within the lesion, cystic versus solid appearance, and margin regularity. Parameters representing the extent of tumor enhancement were defined and calculated. The association between tumor enhancement and Fuhrman grade was analyzed, and multivariate analysis was performed to find independent predictors of high tumor grade. Significant differences existed in tumor enhancement among different Fuhrman grades (p < 0.001). High-grade tumors had significantly lower enhancement (p < 0.001). The enhancement parameter had a sensitivity of 0.84 and specificity of 0.93 in prediction of high tumor grade. In the multivariate analysis, more advanced age, irregular margin, and low tumor enhancement were the three independent predictors of high tumor grade. Tumor enhancement of clear cell renal cell carcinoma on multiphase contrast-enhanced CT images is associated with Fuhrman grade. Low tumor enhancement in the corticomedullary phase is an independent predictor of high tumor grade. This system may be helpful in clinical decision making about the care of patients treated by nonsurgical approaches.
Ippolito, Davide; Fior, Davide; Franzesi, Cammillo Talei; Riva, Luca; Casiraghi, Alessandra; Sironi, Sandro
2017-12-01
Effective radiation dose in coronary CT angiography (CTCA) for coronary artery bypass graft (CABG) evaluation is remarkably high because of long scan lengths. Prospective electrocardiographic gating with iterative reconstruction can reduce effective radiation dose. To evaluate the diagnostic performance of low-kV CT angiography protocol with prospective ecg-gating technique and iterative reconstruction (IR) algorithm in follow-up of CABG patients compared with standard retrospective protocol. Seventy-four non-obese patients with known coronary disease treated with artery bypass grafting were prospectively enrolled. All the patients underwent 256 MDCT (Brilliance iCT, Philips) CTCA using low-dose protocol (100 kV; 800 mAs; rotation time: 0.275 s) combined with prospective ECG-triggering acquisition and fourth-generation IR technique (iDose 4 ; Philips); all the lengths of the bypass graft were included in the evaluation. A control group of 42 similar patients was evaluated with a standard retrospective ECG-gated CTCA (100 kV; 800 mAs).On both CT examinations, ROIs were placed to calculate standard deviation of pixel values and intra-vessel density. Diagnostic quality was also evaluated using a 4-point quality scale. Despite the statistically significant reduction of radiation dose evaluated with DLP (study group mean DLP: 274 mGy cm; control group mean DLP: 1224 mGy cm; P value < 0.001). No statistical differences were found between PGA group and RGH group regarding intra-vessel density absolute values and SNR. Qualitative analysis, evaluated by two radiologists in "double blind", did not reveal any significant difference in diagnostic quality of the two groups. The development of high-speed MDCT scans combined with modern IR allows an accurate evaluation of CABG with prospective ECG-gating protocols in a single breath hold, obtaining a significant reduction in radiation dose.
Marwan, Mohamed; Hausleiter, Jörg; Abbara, Suhny; Hoffmann, Udo; Becker, Christoph; Ovrehus, Kristian; Ropers, Dieter; Bathina, Ravi; Berman, Dan; Anders, Katharina; Uder, Michael; Meave, Aloha; Alexánderson, Erick; Achenbach, Stephan
2014-01-01
The diagnostic performance of multidetector row CT to detect coronary artery stenosis has been evaluated in numerous single-center studies, with only limited data from large cohorts with low-to-intermediate likelihood of coronary disease and in multicenter trials. The Multicenter Evaluation of Coronary Dual-Source CT Angiography in Patients with Intermediate Risk of Coronary Artery Stenoses (MEDIC) trial determines the accuracy of dual-source CT (DSCT) to identify persons with at least 1 coronary artery stenosis among patients with low-to-intermediate pretest likelihood of disease. The MEDIC trial was designed as a prospective, multicenter, international trial to evaluate the diagnostic performance of DSCT for the detection of coronary artery stenosis compared with invasive coronary angiography. The study includes 8 sites in Germany, India, Mexico, the United States, and Denmark. The study population comprises patients referred for a diagnostic coronary angiogram because of suspected coronary artery disease with an intermediate pretest likelihood as determined by sex, age, and symptoms. All evaluations are performed by blinded core laboratory readers. The primary outcome of the MEDIC trial is the accuracy of DSCT to identify the presence of coronary artery stenoses with a luminal diameter narrowing of 50% or more on a per-vessel basis. Secondary outcome parameters include per-patient and per-segment diagnostic accuracy for 50% stenoses and accuracy to identify stenoses of 70% or more. Furthermore, secondary outcome parameters include the influence of heart rate, Agatston score, body weight, body mass index, image quality, and diagnostic confidence on the accuracy to detect coronary artery stenoses >50% on a per-vessel basis. The results of the MEDIC trial will assess the clinical utility of coronary CT angiography in the evaluation of patients with intermediate pretest likelihood of coronary artery disease. Copyright © 2014 Society of Cardiovascular Computed Tomography. All rights reserved.
Pediatric Chest and Abdominopelvic CT: Organ Dose Estimation Based on 42 Patient Models
Tian, Xiaoyu; Li, Xiang; Segars, W. Paul; Paulson, Erik K.; Frush, Donald P.
2014-01-01
Purpose To estimate organ dose from pediatric chest and abdominopelvic computed tomography (CT) examinations and evaluate the dependency of organ dose coefficients on patient size and CT scanner models. Materials and Methods The institutional review board approved this HIPAA–compliant study and did not require informed patient consent. A validated Monte Carlo program was used to perform simulations in 42 pediatric patient models (age range, 0–16 years; weight range, 2–80 kg; 24 boys, 18 girls). Multidetector CT scanners were modeled on those from two commercial manufacturers (LightSpeed VCT, GE Healthcare, Waukesha, Wis; SOMATOM Definition Flash, Siemens Healthcare, Forchheim, Germany). Organ doses were estimated for each patient model for routine chest and abdominopelvic examinations and were normalized by volume CT dose index (CTDIvol). The relationships between CTDIvol-normalized organ dose coefficients and average patient diameters were evaluated across scanner models. Results For organs within the image coverage, CTDIvol-normalized organ dose coefficients largely showed a strong exponential relationship with the average patient diameter (R2 > 0.9). The average percentage differences between the two scanner models were generally within 10%. For distributed organs and organs on the periphery of or outside the image coverage, the differences were generally larger (average, 3%–32%) mainly because of the effect of overranging. Conclusion It is feasible to estimate patient-specific organ dose for a given examination with the knowledge of patient size and the CTDIvol. These CTDIvol-normalized organ dose coefficients enable one to readily estimate patient-specific organ dose for pediatric patients in clinical settings. This dose information, and, as appropriate, attendant risk estimations, can provide more substantive information for the individual patient for both clinical and research applications and can yield more expansive information on dose profiles across patient populations within a practice. © RSNA, 2013 PMID:24126364
Mishra, Atul; Jain, Narendra; Bhagwat, Anand
2017-07-01
Peripheral arterial occlusive disease (PAOD) may cause disabling claudication or critical limb ischemia. Multidetector computed tomography (CT) technology has evolved to the level of 256-slice CT scanners which has significantly improved the spatial and temporal resolution of the images. This has provided the capability of chasing the contrast bolus at a fast speed enabling angiographic imaging of long segments of the body. These images can be reconstructed in various planes and various modes for detailed analysis of the peripheral vascular diseases which helps in making treatment decision. The aim of this retrospective study was to compare the CT angiograms (CTAs) of all cases of PAOD done by 256-slice CT scanner at a tertiary care vascular center and comparing these images with the digital subtraction angiograms (DSAs) of these patients. The retrospective study included 53 patients who underwent both CTA and DSA at our center over a period of 3 years from March 2013 to March 2016. The CTA showed high sensitivity (93%) and specificity (92.7%) for overall assessment of degree of stenosis in a vascular segment in cases of aortic and lower limb occlusive disease. The assessment of lesions of infrapopliteal segment was comparatively inferior (sensitivity 91.6%, accuracy 73.3%, and positive predictive value 78.5%), more so in the presence of significant calcification. The advantages of CTA were its noninvasive nature, ability to image large area of body, almost no adverse effects to the patients, and better assessment of vessel wall disease. However, the CTA assessment of collaterals was inferior with a sensitivity of only 62.7% as compared to DSA. Overall, 256-slice CTA provides fast and accurate imaging of vascular tree which can restrict DSA only in few selected cases as a problem-solving tool where clinico-radiological mismatch is present.
Saha, Punam K; Xu, Yan; Duan, Hong; Heiner, Anneliese; Liang, Guoyuan
2010-11-01
Trabecular bone (TB) is a complex quasi-random network of interconnected plates and rods. TB constantly remodels to adapt to the stresses to which it is subjected (Wolff's Law). In osteoporosis, this dynamic equilibrium between bone formation and resorption is perturbed, leading to bone loss and structural deterioration. Both bone loss and structural deterioration increase fracture risk. Bone's mechanical behavior can only be partially explained by variations in bone mineral density, which led to the notion of bone structural quality. Previously, we developed digital topological analysis (DTA) which classifies plates, rods, profiles, edges, and junctions in a TB skeletal representation. Although the method has become quite popular, a major limitation of DTA is that it provides only hard classifications of different topological entities, failing to distinguish between narrow and wide plates. Here, we present a new method called volumetric topological analysis (VTA) for regional quantification of TB topology. At each TB location, the method uniquely classifies its topology on the continuum between perfect plates and perfect rods, facilitating early detections of TB alterations from plates to rods according to the known etiology of osteoporotic bone loss. Several new ideas, including manifold distance transform, manifold scale, and feature propagation have been introduced here and combined with existing DTA and distance transform methods, leading to the new VTA technology. This method has been applied to multidetector computed tomography (CT) and micro-computed tomography ( μCT) images of four cadaveric distal tibia and five distal radius specimens. Both intra- and inter-modality reproducibility of the method has been examined using repeat CT and μCT scans of distal tibia specimens. Also, the method's ability to predict experimental biomechanical properties of TB via CT imaging under in vivo conditions has been quantitatively examined and the results found are very encouraging.
Predictors of condom use and refusal among the population of Free State province in South Africa
2012-01-01
Background This study investigated the extent and predictors of condom use and condom refusal in the Free State province in South Africa. Methods Through a household survey conducted in the Free Sate province of South Africa, 5,837 adults were interviewed. Univariate and multivariate survey logistic regressions and classification trees (CT) were used for analysing two response variables ‘ever used condom’ and ‘ever refused condom’. Results Eighty-three per cent of the respondents had ever used condoms, of which 38% always used them; 61% used them during the last sexual intercourse and 9% had ever refused to use them. The univariate logistic regression models and CT analysis indicated that a strong predictor of condom use was its perceived need. In the CT analysis, this variable was followed in importance by ‘knowledge of correct use of condom’, condom availability, young age, being single and higher education. ‘Perceived need’ for condoms did not remain significant in the multivariate analysis after controlling for other variables. The strongest predictor of condom refusal, as shown by the CT, was shame associated with condoms followed by the presence of sexual risk behaviour, knowing one’s HIV status, older age and lacking knowledge of condoms (i.e., ability to prevent sexually transmitted diseases and pregnancy, availability, correct and consistent use and existence of female condoms). In the multivariate logistic regression, age was not significant for condom refusal while affordability and perceived need were additional significant variables. Conclusions The use of complementary modelling techniques such as CT in addition to logistic regressions adds to a better understanding of condom use and refusal. Further improvement in correct and consistent use of condoms will require targeted interventions. In addition to existing social marketing campaigns, tailored approaches should focus on establishing the perceived need for condom-use and improving skills for correct use. They should also incorporate interventions to reduce the shame associated with condoms and individual counselling of those likely to refuse condoms. PMID:22639964
Effective and organ doses from common CT examinations in one general hospital in Tehran, Iran
NASA Astrophysics Data System (ADS)
Khoramian, Daryoush; Hashemi, Bijan
2017-09-01
Purpose: It is well known that the main portion of artificial sources of ionizing radiation to human results from X-ray imaging techniques. However, reports carried out in various countries have indicated that most of their cumulative doses from artificial sources are due to CT examinations. Hence assessing doses resulted from CT examinations is highly recommended by national and international radiation protection agencies. The aim of this research has been to estimate the effective and organ doses in an average human according to 103 and 60 ICRP tissue weighting factor for six common protocols of Multi-Detector CT (MDCT) machine in a comprehensive training general hospital in Tehran/Iran. Methods: To calculate the patients' effective dose, the CT-Expo2.2 software was used. Organs/tissues and effective doses were determined for about 20 patients (totally 122 patients) for every one of six typical CT protocols of the head, neck, chest, abdomen-pelvis, pelvis and spine exams. In addition, the CT dosimetry index (CTDI) was measured in the standard 16 and 32 cm phantoms by using a calibrated pencil ionization chamber for the six protocols and by taking the average value of CT scan parameters used in the hospital compared with the CTDI values displayed on the console device of the machine. Results: The values of the effective dose based on the ICRP 103 tissue weighting factor were: 0.6, 2.0, 3.2, 4.2, 2.8, and 3.9 mSv and based on the ICRP 60 tissue weighting factor were: 0.9, 1.4, 3, 7.9, 4.8 and 5.1 mSv for the head, neck, chest, abdomen-pelvis, pelvis, spine CT exams respectively. Relative differences between those values were -22, 21, 23, -6, -31 and 16 percent for the head, neck, chest, abdomen-pelvis, pelvis, spine CT exams, respectively. The average value of CTDIv calculated for each protocol was: 27.32 ± 0.9, 18.08 ± 2.0, 7.36 ± 2.6, 8.84 ± 1.7, 9.13 ± 1.5, 10.42 ± 0.8 mGy for the head, neck, chest, abdomen-pelvis and spine CT exams, respectively. Conclusions: The highest organ doses delivered by various CT exams were received by brain (15.5 mSv), thyroid (19.00 mSv), lungs (9.3 mSv) and bladder (9.9 mSv), bladder (10.4 mSv), stomach (10.9 mSv) in the head, neck, chest, and the abdomen-pelvis, pelvis, and spine respectively. Except the neck and spine CT exams showing a higher effective dose compared to that reported in Netherlands, other exams indicated lower values compared to those reported by any other country.
Brewer, Amandaa K; Striegel, André M
2011-04-15
The string-of-pearls-type morphology is ubiquitous, manifesting itself variously in proteins, vesicles, bacteria, synthetic polymers, and biopolymers. Characterizing the size and shape of analytes with such morphology, however, presents a challenge, due chiefly to the ease with which the "strings" can be broken during chromatographic analysis or to the paucity of information obtained from the benchmark microscopy and off-line light scattering methods. Here, we address this challenge with multidetector hydrodynamic chromatography (HDC), which has the ability to determine, simultaneously, the size, shape, and compactness and their distributions of string-of-pearls samples. We present the quadruple-detector HDC analysis of colloidal string-of-pearls silica, employing static multiangle and quasielastic light scattering, differential viscometry, and differential refractometry as detection methods. The multidetector approach shows a sample that is broadly polydisperse in both molar mass and size, with strings ranging from two to five particles, but which also contains a high concentration of single, unattached "pearls". Synergistic combination of the various size parameters obtained from the multiplicity of detectors employed shows that the strings with higher degrees of polymerization have a shape similar to the theory-predicted shape of a Gaussian random coil chain of nonoverlapping beads, while the strings with lower degrees of polymerization have a prolate ellipsoidal shape. The HDC technique is contrasted experimentally with multidetector size-exclusion chromatography, where, even under extremely gentle conditions, the strings still degraded during analysis. Such degradation is shown to be absent in HDC, as evidenced by the fact that the molar mass and radius of gyration obtained by HDC with multiangle static light scattering detection (HDC/MALS) compare quite favorably to those determined by off-line MALS analysis under otherwise identical conditions. The multidetector HDC results were also comparable to those obtained by transmission electron microscopy (TEM). Unlike off-line MALS or TEM, however, multidetector HDC is able to provide complete particle analysis based on the molar mass, size, shape, and compactness and their distributions for the entire sample population in less than 20 min. © 2011 American Chemical Society
Largo, Remo; Stolzmann, Paul; Fankhauser, Christian D; Poyet, Cédric; Wolfsgruber, Pirmin; Sulser, Tullio; Alkadhi, Hatem; Winklhofer, Sebastian
2016-06-01
This study investigates the capabilities of low tube voltage computed tomography (CT) and dual-energy CT (DECT) for predicting successful shock wave lithotripsy (SWL) of urinary stones in vitro. A total of 33 urinary calculi (six different chemical compositions; mean size 6 ± 3 mm) were scanned using a dual-source CT machine with single- (120 kVp) and dual-energy settings (80/150, 100/150 Sn kVp) resulting in six different datasets. The attenuation (Hounsfield Units) of calculi was measured on single-energy CT images and the dual-energy indices (DEIs) were calculated from DECT acquisitions. Calculi underwent SWL and the number of shock waves for successful disintegration was recorded. The prediction of required shock waves regarding stone attenuation/DEI was calculated using regression analysis (adjusted for stone size and composition) and the correlation between CT attenuation/DEI and the number of shock waves was assessed for all datasets. The median number of shock waves for successful stone disintegration was 72 (interquartile range 30-361). CT attenuation/DEI of stones was a significant, independent predictor (P < 0.01) for the number of required shock waves with the best prediction at 80 kVp (β estimate 0.576) (P < 0.05). Correlation coefficients between attenuation/DEI and the number of required shock waves ranged between ρ = 0.31 and 0.68 showing the best correlation at 80 kVp (P < 0.001). The attenuation of urinary stones at low tube voltage CT is the best predictor for successful stone disintegration, being independent of stone composition and size. DECT shows no added value for predicting the success of SWL.
Nishizawa, Takuya; Maeda, Shigenobu; Goldman, Ran D; Hayashi, Hiroyuki
2018-01-01
This study aimed to determine which children with suspected appendicitis should be considered for a computerized tomography (CT) scan after a non-diagnostic ultrasound (US) in the Emergency Department (ED). We retrospectively reviewed patients 0-18year old, who presented to the ED with complaints of abdominal pain, during 2011-2015 and while in the hospital had both US and CT. We recorded demographic and clinical data and outcomes, and used univariate and multivariate methods for comparing patients who did and didn't have appendicitis on CT after non-diagnostic US. Multivariate analysis was performed using logistic regression to determine what variables were independently associated with appendicitis. A total of 328 patients were enrolled, 257 with non-diagnostic US (CT: 82 had appendicitis, 175 no-appendicitis). Younger children and those who reported vomiting or had right lower abdominal quadrant (RLQ) tenderness, peritoneal signs or White Blood Cell (WBC) count >10,000 in mm 3 were more likely to have appendicitis on CT. RLQ tenderness (Odds Ratio: 2.84, 95%CI: 1.07-7.53), peritoneal signs (Odds Ratio: 11.37, 95%CI: 5.08-25.47) and WBC count >10,000 in mm 3 (Odds Ratio: 21.88, 95%CI: 7.95-60.21) remained significant after multivariate analysis. Considering CT with 2 or 3 of these predictors would have resulted in sensitivity of 94%, specificity of 67%, positive predictive value of 57% and negative predictive value of 96% for appendicitis. Ordering CT should be considered after non-diagnostic US for appendicitis only when children meet at least 2 predictors of RLQ tenderness, peritoneal signs and WBC>10,000 in mm 3 . Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Petruse, Radu Emanuil; Batâr, Sergiu; Cojan, Adela; Maniţiu, Ioan
2014-11-01
Coronary computed tomography angiography (CCTA) allows coronary artery visualization and the detection of coronary stenoses. In addition; it has been suggested as a novel, noninvasive modality for coronary atherosclerotic plaque detection, characterization, and quantification. Accurate identification of coronary plaques is challenging, especially for the noncalcified plaques, due to many factors such as the small size of coronary arteries, reconstruction artifacts caused by irregular heartbeats, beam hardening, and partial volume averaging. The development of 16, 32, 64 and the latest 320 row multidetector CT not only increases the spatial and the temporal resolution significantly, but also increases the number of images to be interpreted by radiologists substantially. Radiologists have to visually examine each coronary artery for suspicious stenosis using visualization tools such as multiplanar reformatting (MPR) and curved planar reformatting (CPR) provided by the review workstation in clinical practice
System for definition of the central-chest vasculature
NASA Astrophysics Data System (ADS)
Taeprasartsit, Pinyo; Higgins, William E.
2009-02-01
Accurate definition of the central-chest vasculature from three-dimensional (3D) multi-detector CT (MDCT) images is important for pulmonary applications. For instance, the aorta and pulmonary artery help in automatic definition of the Mountain lymph-node stations for lung-cancer staging. This work presents a system for defining major vascular structures in the central chest. The system provides automatic methods for extracting the aorta and pulmonary artery and semi-automatic methods for extracting the other major central chest arteries/veins, such as the superior vena cava and azygos vein. Automatic aorta and pulmonary artery extraction are performed by model fitting and selection. The system also extracts certain vascular structure information to validate outputs. A semi-automatic method extracts vasculature by finding the medial axes between provided important sites. Results of the system are applied to lymph-node station definition and guidance of bronchoscopic biopsy.
The masticator space: from anatomy to pathology.
Faye, N; Lafitte, F; Williams, M; Guermazi, A; Sahli-Amor, M; Chiras, J; Dion, E
2009-06-01
The masticator space is a deep facial space with a complex anatomical structure. The purpose of the present study was to precisely define the masticator space to eliminate the use of obsolete and confusing terms to describe the area, and to illustrate the common mass syndromes. Primary tumors are uncommon, usually benign and of a vascular or neural origin. Adjacent lesions, mainly pharyngeal with secondary extension into the masticator space, are especially frequent. Metastases are rare, and infectious pathology is often odontogenic. The most frequent lesion of the masticator space is the odontogenic abscess. Multidetector CT and MRI enable precise study of the space, its communications with other deep spaces and the etiology of any mass syndrome. Understanding the anatomy of the masticator space and how it links up with the other deep facial spaces helps the radiologist to recognize the different lesions of this space and to avoid unnecessary surgery, or any other less than optimal management.
Aneurysmal coronary cameral fistula
Jamil, Gohar; Khan, Asad; Malik, Azhar; Qureshi, Anwer
2013-01-01
A 26-year-old asymptomatic man, being medically managed for ventricular septal defect since childhood, presented to the outpatient clinic for a second opinion. Clinically, he was well built with normal vital signs. Cardiac auscultation was significant for a diastolic murmur over the praecordium. An ECG showed non-specific ST changes, and a subsequent transthoracic echocardiography performed revealed diastolic flow from the left ventricular (LV) anteroseptal wall into the LV cavity. A diagnosis of coronary–cameral fistula was confirmed by a multidetector CT which showed a 2.5×2 cm aneurysmal left anterior descending artery fistula to the LV. In addition to starting aspirin, transcatheter closure with occlusion device was considered knowing the potential risk of thrombus formation in the aneurysm and subsequent systemic embolisation. The patient however refused any percutaneous or surgical intervention. He remains asymptomatic 1 year after returning to his home country. PMID:23737570
Koopmann, Mario; Weiss, Daniel; Steiger, Matthias; Elges, Sandra; Rudack, Claudia; Stenner, Markus
2016-11-01
The objective of this study is to analyze the accuracy of computed tomography in detecting malignant thyroid cartilage invasion. In a retrospective chart review, 120 patients with carcinoma of the larynx and hypopharynx underwent computed tomography before total laryngectomy. These data were compared with the histological specimens. Multidetector computed tomography (MDCT) scan had a positive predictive value (PPV) of 76 % and a negative predictive value (NPV) of 69 %. The specificity of MDCT was 89 % and sensitivity was 46 %. Comparison between radiologic suspected cartilage invasion and histologic results showed a significant correlation (p < 0.02). We found no significant impact of cartilage invasion concerning survival rates (5-year overall survival p = 0.683; 5-year disease-free survival p = 0.711). Preoperative CT scan is an important instrument in detecting neoplastic cartilage invasion.
Tracheobronchomegaly associated tracheomalacia: analysis by sleep study.
Sundaram, P; Joshi, J M
2004-01-01
Tracheobronchomegaly (TBM) occasionally may progress to extensive tracheomalacia which leads to respiratory failure. Spirometry, dynamic expiratory multidetector computed tomography (CT), bronchoscopy are used to diagnose patients of suspected tracheobronchomalacia. We used the technique of night-time monitoring of respiratory variables to show the presence of respiratory abnormalities during sleep and which was corrected by applying nasal continuous positive airway pressure (CPAP). The study showed the presence of both apnoea and hypopnoeas, which were obstructive in nature with an apnoea-hypopnoea index (AHI) of 11, no snoring and associated oxygen desaturation of 75 per cent. A second overnight study with nasal continuous positive airway pressure at a critical pressure of 8 cm, the AHI decreased to 3 along with no drop in oxygen saturation. This non-invasive technique should be considered as a diagnostic tool in tracheobronchomalacia and to know the outcome of CPAP, surgical or stent therapy in this condition.
Large arterial occlusive strokes as a medical emergency: need to accurately predict clot location.
Vanacker, Peter; Faouzi, Mohamed; Eskandari, Ashraf; Maeder, Philippe; Meuli, Reto; Michel, Patrik
2017-10-01
Endovascular treatment for acute ischemic stroke with a large intracranial occlusion was recently shown to be effective. Timely knowledge of the presence, site, and extent of arterial occlusions in the ischemic territory has the potential to influence patient selection for endovascular treatment. We aimed to find predictors of large vessel occlusive strokes, on the basis of available demographic, clinical, radiological, and laboratory data in the emergency setting. Patients enrolled in ASTRAL registry with acute ischemic stroke and computed tomography (CT)-angiography within 12 h of stroke onset were selected and categorized according to occlusion site. Easily accessible variables were used in a multivariate analysis. Of 1645 patients enrolled, a significant proportion (46.2%) had a large vessel occlusion in the ischemic territory. The main clinical predictors of any arterial occlusion were in-hospital stroke [odd ratios (OR) 2.1, 95% confidence interval 1.4-3.1], higher initial National Institute of Health Stroke Scale (OR 1.1, 1.1-1.2), presence of visual field defects (OR 1.9, 1.3-2.6), dysarthria (OR 1.4, 1.0-1.9), or hemineglect (OR 2.0, 1.4-2.8) at admission and atrial fibrillation (OR 1.7, 1.2-2.3). Further, the following radiological predictors were identified: time-to-imaging (OR 0.9, 0.9-1.0), early ischemic changes (OR 2.3, 1.7-3.2), and silent lesions on CT (OR 0.7, 0.5-1.0). The area under curve for this analysis was 0.85. Looking at different occlusion sites, National Institute of Health Stroke Scale and early ischemic changes on CT were independent predictors in all subgroups. Neurological deficits, stroke risk factors, and CT findings accurately identify acute ischemic stroke patients at risk of symptomatic vessel occlusion. Predicting the presence of these occlusions may impact emergency stroke care in regions with limited access to noninvasive vascular imaging.
Savić, Živorad N.; Soldatović, Ivan I.; Brajović, Milan D.; Pavlović, Aleksandra M.; Mladenović, Dušan R.; Škodrić-Trifunović, Vesna D.
2011-01-01
The increased thickness of the carotid wall >1 mm is a significant predictor of coronary and cerebrovascular diseases. The purpose of our study was to assess the agreement between multidetector row computed tomography angiography (MDCTA) in measuring carotid artery wall thickness (CAWT) and color Doppler ultrasound (CD-US) in measuring intimae-media thickness (IMT). Eighty-nine patients (aged 35–81) were prospectively analyzed using a 64-detector MDCTA and a CD-US scanner. Continuous data were described as the mean value ± standard deviation, and were compared using the Mann–Whitney U test. A p value <0.05 was considered significant. Bland–Altman statistics were employed to measure the agreement between MDCTA and CD-US. CAWT ranged from 0.62 to 1.60 mm, with a mean value of 1.09 mm. IMT ranged from 0.60 to 1.55 mm, with a mean value of 1.06 mm. We observed an excellent agreement between CD-US and MDCTA in the evaluation of the common carotid artery thickness, with a bias between methods of 0.029 mm (which is a highly statistically important difference of absolute values [t = 43.289; p < 0.01] obtained by paired T test), and limits of agreement from 0.04 to 0.104. Pearson correlation coefficient was 0.9997 (95% CI 0.9996–0.9998; p < 0.01). We conclude that there is an excellent correlation between CAWT and IMT measurements obtained with the MDCTA and CD-US. PMID:22224072
Abdullah, Kamarul A; McEntee, Mark F; Reed, Warren; Kench, Peter L
2018-04-30
An ideal organ-specific insert phantom should be able to simulate the anatomical features with appropriate appearances in the resultant computed tomography (CT) images. This study investigated a 3D printing technology to develop a novel and cost-effective cardiac insert phantom derived from volumetric CT image datasets of anthropomorphic chest phantom. Cardiac insert volumes were segmented from CT image datasets, derived from an anthropomorphic chest phantom of Lungman N-01 (Kyoto Kagaku, Japan). These segmented datasets were converted to a virtual 3D-isosurface of heart-shaped shell, while two other removable inserts were included using computer-aided design (CAD) software program. This newly designed cardiac insert phantom was later printed by using a fused deposition modelling (FDM) process via a Creatbot DM Plus 3D printer. Then, several selected filling materials, such as contrast media, oil, water and jelly, were loaded into designated spaces in the 3D-printed phantom. The 3D-printed cardiac insert phantom was positioned within the anthropomorphic chest phantom and 30 repeated CT acquisitions performed using a multi-detector scanner at 120-kVp tube potential. Attenuation (Hounsfield Unit, HU) values were measured and compared to the image datasets of real-patient and Catphan ® 500 phantom. The output of the 3D-printed cardiac insert phantom was a solid acrylic plastic material, which was strong, light in weight and cost-effective. HU values of the filling materials were comparable to the image datasets of real-patient and Catphan ® 500 phantom. A novel and cost-effective cardiac insert phantom for anthropomorphic chest phantom was developed using volumetric CT image datasets with a 3D printer. Hence, this suggested the printing methodology could be applied to generate other phantoms for CT imaging studies. © 2018 The Authors. Journal of Medical Radiation Sciences published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Medical Imaging and Radiation Therapy and New Zealand Institute of Medical Radiation Technology.
Imaging of Combat-Related Thoracic Trauma - Review of Penetrating Trauma.
Lichtenberger, John P; Kim, Andrew M; Fisher, Dane; Tatum, Peter S; Neubauer, Brian; Peterson, P Gabriel; Carter, Brett W
2018-03-01
Combat-related thoracic trauma is a significant contributor to morbidity and mortality of the casualties from Operation Enduring Freedom (OEF) and Operation Iraqi Freedom (OIF). Penetrating, blunt, and blast injuries were the most common mechanisms of trauma. Imaging plays a key role in the management of combat-related thoracic trauma casualties. This review discusses the imaging manifestations of thoracic injuries from penetrating trauma, emphasizing epidemiology and diagnostic clues seen during OEF and OIF. The assessment of radiologic findings in patients who suffer from combat-related thoracic trauma is the basis of this review article. The imaging modalities for this study include multi-detector computed tomography and chest radiography. High-velocity penetrating projectile injuries appear as hemorrhage and re-expansion pulmonary edema from the temporary cavity and a linear, blood-filled track from the permanent cavity. In cases where the projectile passes totally through the body, entrance wounds at the skin surface and tracks through the subcutaneous tissues may be the only indications of penetrating trauma. When assessing vascular injury, special attention should be paid to the right hilum in contrast-enhanced multi-detector computed tomography, as contrast is concentrated in the superior vena cava and superior cavoatrial junction may obscure small fragments. Additionally, CT angiography may show vessel disruption or extravasation of contrast distal to normal vessel location in addition to intraluminal filling defects and pseudo-aneurysms. Tension pneumopericardium may rarely complicate penetrating or blunt chest trauma. On imaging, distension of the pericardial sack by pneumopericardium and compression of the heart support the diagnosis of tension. On multi-detector computed tomography in the acute trauma setting, fluid in the pleural space should be considered hemothorax, particularly when Hounsfield units are above 35. Acutely, extravasated blood will have similar attenuation to the thoracic vasculature, whereas clotted blood will have higher values of 50-90 Hounsfield units. Combat-related thoracic trauma continues to be a significant contributor to the morbidity and mortality of those injured during OEF and OIF. This review of the imaging manifestations of penetrating thoracic injury during OEF and OIF focuses on key diagnostic findings for clinicians caring for combat casualties. The distinct injury pattern and atypical imaging manifestations of penetrating trauma are important to recognize early due to the acuity of this patient population and the influence of accurate diagnosis on clinical management.
Zeitoun, Rania; Hussein, Manar
2017-11-01
To reach a practical approach to interpret MDCT findings in post-operative spine cases and to change the false belief of CT failure in the setting of instruments secondary to related artefacts. We performed observational retrospective analysis of premier, early and late MDCT scans in 68 post-operative spine patients, with emphasis on instruments related complications and osseous fusion status. We used a grading system for assessment of osseous fusion in 35 patients and we further analysed the findings in failure of fusion, grade (D). We observed a variety of instruments related complications (mostly screws medially penetrating the pedicle) and osseous fusion status in late scans. We graded 11 interbody and 14 posterolateral levels as osseous fusion failure, showing additional instruments related complications, end plates erosive changes, adjacent segments spondylosis and malalignment. Modern MDCT scanners provide high quality images and are strongly recommended in assessment of the instruments and status of osseous fusion. In post-operative imaging of the spine, it is essential to be aware for what you are looking for, in relevance to the date of surgery. Advances in knowledge: Modern MDCT scanners allow assessment of instruments position and integrity and osseous fusion status in post-operative spine. We propose a helpful algorithm to simplify interpreting post-operative spine imaging.
Inokuchi, Go; Yajima, Daisuke; Hayakawa, Mutsumi; Motomura, Ayumi; Chiba, Fumiko; Torimitsu, Suguru; Makino, Yohsuke; Iwase, Hirotaro
2014-12-01
One of the advantages of postmortem imaging is its ability to obtain diagnostic findings in a non-destructive manner when autopsy is either difficult or may destroy forensic evidence. In recent years, efforts have been made to incorporate computed tomography (CT) based postmortem angiography into forensic pathology; however, it is not currently clear how well the modality can determine sites of bleeding in cases of subarachnoid hemorrhage. Therefore, in this study, we investigated the utility of postmortem cerebral angiography using multi-detector row CT (MDCT) by injecting a contrast medium through a catheter inserted into the internal carotid and vertebral arteries of 10 subarachnoid hemorrhage cases. While postmortem MDCT angiography (PMCTA) was capable of detecting aneurysms in a non-destructive manner, it was sometimes difficult to identify the aneurysm and bleeding sites because of a large amount of contrast medium leaking into the extravascular space. To overcome this problem, we developed the novel contrast imaging method "dynamic cerebral angiography," which involves scanning the same area multiple times while injecting contrast medium to enable real-time observation of the contrasted vasculature. Using multiphase contrast images acquired by this method, we successfully captured the moment when contrast medium leaked from the hemorrhage site. This method will be useful for identifying exact bleeding sites on PMCTA.
Multidetector Scattering as a Probe of Local Structure in Disordered Phases
NASA Astrophysics Data System (ADS)
Clark, Noel A.; Ackerson, Bruce J.; Hurd, Alan J.
1983-05-01
The local translational structure of a two-dimensional colloidal liquid is observed by use of cross correlation of the intensity fluctuations of light scattered by the liquid through two different wave vectors. The utility of multidetector scattering in probing multipoint correlations in disordered phases is thereby demonstrated unambiguously.
Noh, Tae June; Lee, Chang Hoon; Kang, Young Ae; Kwon, Sung-Youn; Yoon, Ho-Il; Kim, Tae Jung; Lee, Kyung Won; Lee, Jae Ho
2009-01-01
Background/Aims This study examined the correlation between pneumothorax detected by immediate post-transthoracic needle aspiration-biopsy (TTNB) chest computed tomography (CT) and overt pneumothorax detected by chest PA, and investigated factors that might influence the correlation. Methods Adult patients who had undergone CT-guided TTNB for lung lesions from May 2003 to June 2007 at Seoul National University Bundang Hospital were included. Immediate post-TTNB CT and chest PA follow-up at 4 and 16 hours after CT-guided TTNB were performed in 934 patients. Results Pneumothorax detected by immediate chest CT (CT-pneumothorax) was found in 237 (25%) and overt pneumothorax was detected by chest PA follow-up in 92 (38.8%) of the 237 patients. However, overt pneumothorax was found in 18 (2.6%) of the 697 patients without CT-pneumothorax. The width and depth of CT-pneumothorax were predictive risk factors for overt pneumothorax. Conclusions CT-pneumothorax is very sensitive for predicting overt pneumothorax, and the width and depth on CT-pneumothorax are reliable risk factors for predicting overt pneumothorax. PMID:19949733
Luo, Mingyue; Duan, Chaijie; Qiu, Jianping; Li, Wenru; Zhu, Dongyun; Cai, Wenli
2015-01-01
To evaluate the diagnostic value of multidetector CT (MDCT) and its multiplanar reformation (MPR), volume rendering (VR) and virtual bronchoscopy (VB) postprocessing techniques for primary trachea and main bronchus tumors. Detection results of 31 primary trachea and main bronchus tumors with MDCT and its MPR, VR and VB postprocessing techniques, were analyzed retrospectively with regard to tumor locations, tumor morphologies, extramural invasions of tumors, longitudinal involvements of tumors, morphologies and extents of luminal stenoses, distances between main bronchus tumors and trachea carinae, and internal features of tumors. The detection results were compared with that of surgery and pathology. Detection results with MDCT and its MPR, VR and VB were consistent with that of surgery and pathology, included tumor locations (tracheae, n = 19; right main bronchi, n = 6; left main bronchi, n = 6), tumor morphologies (endoluminal nodes with narrow bases, n = 2; endoluminal nodes with wide bases, n = 13; both intraluminal and extraluminal masses, n = 16), extramural invasions of tumors (brokethrough only serous membrane, n = 1; 4.0 mm-56.0 mm, n = 14; no clear border with right atelectasis, n = 1), longitudinal involvements of tumors (3.0 mm, n = 1; 5.0 mm-68.0 mm, n = 29; whole right main bronchus wall and trachea carina, n = 1), morphologies of luminal stenoses (irregular, n = 26; circular, n = 3; eccentric, n = 1; conical, n = 1) and extents (mild, n = 5; moderate, n = 7; severe, n = 19), distances between main bronchus tumors and trachea carinae (16.0 mm, n = 1; invaded trachea carina, n = 1; >20.0 mm, n = 10), and internal features of tumors (fairly homogeneous densities with rather obvious enhancements, n = 26; homogeneous density with obvious enhancement, n = 1; homogeneous density without obvious enhancement, n = 1; not enough homogeneous density with obvious enhancement, n = 1; punctate calcification with obvious enhancement, n = 1; low density without obvious enhancement, n = 1). MDCT and its MPR, VR and VB images have respective advantages and disadvantages. Their combination could complement to each other to accurately detect locations, natures (benignancy, malignancy or low malignancy), and quantities (extramural invasions, longitudinal involvements, extents of luminal stenoses, distances between main bronchus tumors and trachea carinae) of primary trachea and main bronchus tumors with crucial information for surgical treatment, are highly useful diagnostic methods for primary trachea and main bronchus tumors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Papadakis, Antonios E.; Perisinakis, Kostas; Damilakis, John
2007-07-15
The purpose of this study was to assess the potential of angular on-line tube current modulation on dose reduction in pediatric and adult patients undergoing multidetector computed tomography (MDCT) examinations. Five physical anthropomorphic phantoms that simulate the average individual as neonate, 1-year-old, 5-year-old, 10-year-old, and adult were employed in the current study. Phantoms were scanned with the use of on-line tube current modulation (TCM). Percent dose reduction (%DR) factors achieved by applying TCM, were determined for standard protocols used for head and neck, shoulder, thorax, thorax and abdomen, abdomen, abdomen and pelvis, pelvis, and whole body examinations. A preliminary studymore » on the application of TCM in MDCT examinations of adult patients was performed to validate the results obtained in anthropomorphic phantoms. Dose reduction was estimated as the percentage difference of the modulated milliamperes for each scan and the preset milliamperes prescribed by the scan protocol. The dose reduction in children was found to be much lower than the corresponding reduction achieved for adults. For helical scans the %DR factors, ranged between 1.6% and 7.4% for the neonate, 2.9% and 8.7% for the 1-year old, 2% and 6% for the 5-year-old, 5% and 10.9% for the 10-year-old, and 10.4% and 20.7% for the adult individual. For sequential scans the corresponding %DR factors ranged between 1.3% and 6.7%, 4.5% and 11%, 4.2% and 6.6%, 6.4% and 12.3%, and 8.9% and 23.3%, respectively. Broader beam collimations are associated with decreased %DR factors, when other scanning parameters are held constant. TCM did not impair image noise. In adult patients, the %DR values were found to be in good agreement with the corresponding results obtained in the anthropomorphic adult phantom. In conclusion, on-line TCM may be considered as a valuable tool for reducing dose in routine CT examinations of pediatric and adult patients. However, the dose reduction achieved with TCM in neonates and young children was found to be lower than that obtained for adults. Therefore, on-line TCM should work as an additional means to reduce dose and should not replace other conventional means of reducing dose, especially in neonates and young children.« less
Aircraft mishap investigation with radiology-assisted autopsy: helicopter crash with control injury.
Folio, R Les; Harcke, H Theodore; Luzi, Scott A
2009-04-01
Radiology-assisted autopsy traditionally has been plain film-based, but now is being augmented by computed tomography (CT). The authors present a two-fatality rotary wing crash scenario illustrating application of advanced radiographic techniques that can guide and supplement the forensic pathologist's physical autopsy. The radiographic findings also have the potential for use by the aircraft mishap investigation board. Prior to forensic autopsy, the two crash fatalities were imaged with conventional two-dimensional radiographs (digital technique) and with multidetector CT The CT data were used for multiplanar two-dimensional and three-dimensional (3D) image reconstruction. The forensic pathologist was provided with information about skeletal fractures, metal fragment location, and other pathologic findings of potential use in the physical autopsy. The radiologic autopsy served as a supplement to the physical autopsy and did not replace the traditional autopsy in these cases. Both individuals sustained severe blunt force trauma with multiple fractures of the skull, face, chest, pelvis, and extremities. Individual fractures differed; however, one individual showed hand and lower extremity injuries similar to those associated with control of the aircraft at the time of impact. The concept of "control injury" has been challenged by Campman et al., who found that control surface injuries have a low sensitivity and specificity for establishing who the pilot was in an accident. The application of new post mortem imaging techniques may help to resolve control injury questions. In addition, the combination of injuries in our cases may contribute to further understanding of control surface injury patterns in helicopter mishaps.
How accurate is unenhanced multidetector-row CT (MDCT) for localization of renal calculi?
Goetschi, Stefan; Umbehr, Martin; Ullrich, Stephan; Glenck, Michael; Suter, Stefan; Weishaupt, Dominik
2012-11-01
To investigate the correlation between unenhanced MDCT and intraoperative findings with regard to the exact anatomical location of renal calculi. Fifty-nine patients who underwent unenhanced MDCT for suspected urinary stone disease, and who underwent subsequent flexible ureterorenoscopy (URS) as treatment of nephrolithiasis were included in this retrospective study. All MDCT data sets were independently reviewed by three observers with different degrees of experience in reading CT. Each observer was asked to indicate presence and exact anatomical location of any calcification within pyelocaliceal system, renal papilla or renal cortex. Results were compared to intraoperative findings which have been defined as standard of reference. Calculi not described at surgery, but present on MDCT data were counted as renal cortex calcifications. Overall 166 calculi in 59 kidneys have been detected on MDCT, 100 (60.2%) were located in the pyelocaliceal system and 66 (39.8%) in the renal parenchyma. Of the 100 pyelocaliceal calculi, 84 (84%) were correctly located on CT data sets by observer 1, 62 (62%) by observer 2, and 71 (71%) by observer 3. Sensitivity/specificity was 90-94% and 50-100% if only pyelocaliceal calculi measuring >4 mm in size were considered. For pyelocaliceal calculi≤4 mm in size diagnostic performance of MDCT was inferior. Compared to flexible URS, unenhanced MDCT is accurate for distinction between pyelocaliceal calculi and renal parenchyma calcifications if renal calculi are >4 mm in size. For smaller renal calculi, unenhanced MDCT is less accurate and distinction between a pyelocaliceal calculus and renal parenchyma calcification is difficult. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Ossicles of lumbar articular facets: normal variant or spondylolytic variant?
Kumar, Dalavaye S; Fotiadou, Anastasia; Lalam, Radhesh; Ginder, Laurence M; Eisenstein, Stephen M; Tins, Bernard J; Tyrrell, Prudencia N M; Delieu, John M; McCall, Iain W; Rees, Dai A; Cassar-Pullicino, Victor N
2012-12-01
The objective of this study was to establish the prevalence and significance of ossicles of lumbar articular facets (OLAF) in young athletes with backache diagnosed by multi-detector computed tomography (MDCT). The MDCT examinations of the lumbar spine carried out for suspected spondylolysis on 46 consecutive symptomatic young athletes presenting to a sports injury clinic over a 1-year period were retrospectively reviewed. OLAF study included detailed correlation with the structural and morphological stress features of the posterior neural arches. This was then compared with a control group composed of 39 patients. Twenty-three OLAF were identified in 15 patients. Eleven of the 15 patients with ossicles had posterior element stress changes (PEST)/pars defects. In the control group, two OLAF were identified in two patients, one demonstrating PEST changes. The high prevalence of OLAF in young symptomatic athletes compared with the asymptomatic control group is indicative of stress fractures. The non-united articular process fractures should be regarded as part of the spectrum of stress-induced changes in the posterior neural arch in the same way as spondylolysis. MDCT with volumetric acquisition and multi-planar reformation is the most reliable investigation in the diagnosis of OLAF. 1) This CT study supports a traumatic aetiology for lumbar articular facets ossicles. 2) OLAF represent part of a spectrum of stress-induced changes in the posterior neural arch. 3) OLAF are associated with typical spondylolysis. 4) OLAF can be overlooked on reverse gantry angle computed tomography (RG-CT). 5) OLAF may account for some of the discrepancy between radionuclide and RG-CT studies.
Fernández Pérez, G; Sánchez Escribano, R; García Vicente, A M; Luna Alcalá, A; Ceballos Viro, J; Delgado Bolton, R C; Vilanova Busquets, J C; Sánchez Rovira, P; Fierro Alanis, M P; García Figueiras, R; Alés Martínez, J E
2018-05-25
Imaging in oncology is an essential tool for patient management but its potential is being profoundly underutilized. Each of the techniques used in the diagnostic process also conveys functional information that can be relevant in treatment decision making. New imaging algorithms and techniques enhance our knowledge about the phenotype of the tumor and its potential response to different therapies. Functional imaging can be defined as the one that provides information beyond the purely morphological data, and include all the techniques that make it possible to measure specific physiological functions of the tumor, whereas molecular imaging would include techniques that allow us to measure metabolic changes. Functional and molecular techniques included in this document are based on multi-detector computed tomography (CT), 18F-fluorodeoxyglucose positron emission tomography (18F-FDG PET), magnetic resonance imaging (MRI), and hybrid equipments, integrating PET with CT (PET/CT) or MRI (PET-MRI). Lung cancer is one of the most frequent and deadly tumors although survival is increasing thanks to advances in diagnostic methods and new treatments. This increased survival poises challenges in terms of proper follow-up and definitions of response and progression, as exemplified by immune therapy-related pseudoprogression. In this consensus document, the use of functional and molecular imaging techniques will be addressed to exploit their current potential and explore future applications in the diagnosis, evaluation of response and detection of recurrence of advanced NSCLC. Copyright © 2018 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.
Morphologic classification of the right auricule on 256-slice computed tomography.
Li, Cai-Ying; Gao, Bu-Lang; Pan, Tong; Xiang, Cheng; Liu, Xiao-Wei; Yang, Hai-Qing; Yi, Lan-Ying; Liao, Qi-Bin
2017-06-01
To investigate the shape of right auricule on 256-slice computed tomography (CT). Five hundred people (250 men, age range 16-84 years) who had cardiac multidetector CT angiography were recruited in this study. All patients had normal sinus rhythm with normal blood pressure (<140/90 mmHg for systolic/diastolic pressure). The morphology of the right auricule was studied and compared after reconstruction of the raw images. All patients successfully had cardiac CT angiography (100%), and the right auricule morphology was divided into five types and nine subtypes, including Type I of triangular shape (Ia and Ib), Type II of M shape (IIa and IIb), Type III of L shape (IIIa and IIIb), Type IV of reverse L shape (IVa and IVb), and Type V of balanced shape. The most common type of right auricule is Type IV (28.4%) followed by Type II (24.0%), whereas the least common is Type V (11.0%). Type Ia was present significantly (P < 0.0001) more frequently in females than in males, whereas Type IIa significantly (P = 0.042) more frequently in males than females. No other significant (P > 0.05) sex difference existed in the constitution ratio of the types. The normal angle was greater in Type Ib than in Ia. The greater the normal angle in Type I, the greater the deviation of the right auricule tip towards the left. A good understanding of the right auricule anatomical morphology can better guide atrial pacing, radiofrequency ablation and other surgical procedures while preventing possible intra-procedural complications.
Uebleis, C; Groebner, M; von Ziegler, F; Becker, A; Rischpler, C; Tegtmeyer, R; Becker, C; Lehner, S; Haug, A R; Cumming, P; Bartenstein, P; Franz, W M; Hacker, M
2012-10-01
There has been a lack of standardized workup guidelines for patients with congenital abnormal origin of a coronary artery from the opposite sinus (ACAOS). We aimed to evaluate the use of cardiac hybrid imaging using multi-detector row CT (MDCT) for coronary CT angiography (Coronary CTA) and stress-rest myocardial perfusion SPECT (MPS) for comprehensive diagnosis of symptomatic adult patients with ACAOS. Seventeen symptomatic patients (12 men; 54 ± 13 years) presenting with ACAOS underwent coronary CTA and MPS. Imaging data were analyzed by conventional means, and with additional use of 3D image fusion to allocate stress induced perfusion defects (PD) to their supplying coronary arteries. An anomalous RCA arose from the left anterior sinus in eight patients, an abnormal origin from the right sinus was detected in nine patients (5 left coronary arteries, LCA and 4 LCx). Five of the 17 patients (29%) demonstrated a reversible PD in MPS. There was no correlation between the anatomical variants of ACAOS and the presence of myocardial ischemia. Image fusion enabled the allocation of reversible PD to the anomalous vessel in three patients (two cases in the RCA and the other in the LCA territory); PD in two patients were allocated to the territory of artery giving rise to the anomalies, rather than the anomalies themselves. In a small cohort of adult symptomatic patients with ACAOS anomaly there was no relation found between the specific anatomical variant and the appearance of stress induced myocardial ischemia using cardiac hybrid imaging.
Lim, Bee Kuan; Bux, Shaik Ismail; Rahmat, Kartini; Lam, Sze Yin; Liew, Yew Wai
2012-11-01
We compared the effectiveness of different types of non-commercial neutral oral contrast agents for bowel distension and mural visualisation in computed tomographic (CT) enterography. 90 consecutive patients from a group of 108 were randomly assigned to receive water (n = 30), 3.8% milk (n = 30) or 0.1% gastrografin (n = 30) as oral contrast agent. The results were independently reviewed by two radiologists who were blinded to the contrast agents used. The degree of bowel distension was qualitatively scored on a four-point scale. The discrimination of bowel loops, mural visualisation and visualisation of mucosal folds were evaluated on a 'yes' or 'no' basis. Side effects of the various agents were also recorded. 3.8% milk was significantly superior to water for bowel distension (jejunum, ileum and terminal ileum), discrimination of bowel loops (jejunum and ileum), mural visualisation and visualisation of mucosal folds (ileum and terminal ileum). It was also significantly superior to 0.1% gastrografin for bowel distension, discrimination of bowel loops, mural visualisation and visualisation of mucosal folds (jejunum, ileum and terminal ileum). However, 10% of patients who received 3.8% milk reported immediate post-test diarrhoea. No side effects were documented for patients who received water and 0.1% gastrografin. 3.8% milk is an effective and superior neutral oral contrast agent for the assessment of the jejunum, ileum and terminal ileum in CT enterography. However, further studies are needed to explore other suitable oral contrast agents for CT enterography in lactose- or cow's milk-intolerant patients.
Renoprotective effects of hepatocyte growth factor in the stenotic kidney
Stewart, Nicholas
2013-01-01
Renal microvascular (MV) damage and loss contribute to the progression of renal injury in renal artery stenosis (RAS). Hepatocyte growth factor (HGF) is a powerful angiogenic and antifibrotic cytokine that we showed to be decreased in the stenotic kidney. We hypothesized that renal HGF therapy will improve renal function mainly by protecting the renal microcirculation. Unilateral RAS was induced in 15 pigs. Six weeks later, single-kidney RBF and GFR were quantified in vivo using multidetector computed tomography (CT). Then, intrarenal rh-HGF or vehicle was randomly administered into the stenotic kidney (RAS, n = 8; RAS+HGF, n = 7). Pigs were observed for 4 additional weeks before CT studies were repeated. Renal MV density was quantified by 3D micro-CT ex vivo and histology, and expression of angiogenic and inflammatory factors, apoptosis, and fibrosis was determined. HGF therapy improved RBF and GFR compared with vehicle-treated pigs. This was accompanied by improved renal expression of angiogenic cytokines (VEGF, p-Akt) and tissue-healing promoters (SDF-1, CXCR4, MMP-9), reduced MV remodeling, apoptosis, and fibrosis, and attenuated renal inflammation. However, HGF therapy did not improve renal MV density, which was similarly reduced in RAS and RAS+HGF compared with controls. Using a clinically relevant animal model of RAS, we showed novel therapeutic effects of a targeted renal intervention. Our results show distinct actions on the existing renal microcirculation and promising renoprotective effects of HGF therapy in RAS. Furthermore, these effects imply plasticity of the stenotic kidney to recuperate its function and underscore the importance of MV integrity in the progression of renal injury in RAS. PMID:23269649
SU-E-I-24: Method for CT Automatic Exposure Control Verification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gracia, M; Olasolo, J; Martin, M
Purpose: Design of a phantom and a simple method for the automatic exposure control (AEC) verification in CT. This verification is included in the computed tomography (CT) Spanish Quality Assurance Protocol. Methods: The phantom design is made from the head and the body phantom used for the CTDI measurement and PMMA plates (35×35 cm2) of 10 cm thickness. Thereby, three different thicknesses along the longitudinal axis are obtained which permit to evaluate the longitudinal AEC performance. Otherwise, the existent asymmetry in the PMMA layers helps to assess angular and 3D AEC operation.Recent acquisition in our hospital (August 2014) of Nomexmore » electrometer (PTW), together with the 10 cm pencil ionization chamber, led to register dose rate as a function of time. Measurements with this chamber fixed at 0° and 90° on the gantry where made on five multidetector-CTs from principal manufacturers. Results: Individual analysis of measurements shows dose rate variation as a function of phantom thickness. The comparative analysis shows that dose rate is kept constant in the head and neck phantom while the PMMA phantom exhibits an abrupt variation between both results, being greater results at 90° as the thickness of the phantom is 3.5 times larger than in the perpendicular direction. Conclusion: Proposed method is simple, quick and reproducible. Results obtained let a qualitative evaluation of the AEC and they are consistent with the expected behavior. A line of future development is to quantitatively study the intensity modulation and parameters of image quality, and a possible comparative study between different manufacturers.« less
Kitzing, Yu Xuan; Ng, Bernard H K; Kitzing, Bjoern; Waugh, Richard; Kench, James G; Strasser, Simone I; McCormack, Samuel
2015-12-01
Washout is an important diagnostic imaging feature of hepatocellular carcinoma (HCC) on computed tomography (CT). The primary aim of this study is to evaluate the prevalence and the interobserver variation in the detection of portal venous phase (PVP) washout of HCCs using CT in a transplant population. The secondary aim is to evaluate factors influencing the detection of PVP washout. Forty-five patients who underwent CT liver imaging within the 60 days before transplantation had viable HCCs confirmed on pathology. Two radiologists retrospectively reviewed the images for HCCs including features of arterial enhancement and PVP washout. Clinical data, peak kilovoltage, imaging features of portal hypertension, region of interest attenuation measurements of the individual lesions, background liver parenchyma and portal vein were obtained. Liver to lesion attenuation ratio was also calculated. Statistical analysis was performed. The two readers identified 50 arterially enhancing HCCs in 45 patients. In consensus, the two readers identified washout in 60% of the HCCs with a substantial interobserver agreement (kappa = 0.633). PVP washout was associated with larger lesion size, increased background liver parenchyma attenuation, increased liver to lesion attenuation ratio, increased portal vein attenuation and hepatitis B viral status (P = 0.027, 0.008, 0.014, 0.017 and 0.037 respectively). In our transplant population, portal venous phase washout was seen in 60% of the hypervascular HCCs. Factors influencing the presence of PVP washout include lesion size as well as the liver and portal vein attenuation reflective of the portal haemodynamics. © 2015 The Royal Australian and New Zealand College of Radiologists.
Kusk, Martin Weber; Karstoft, Jens; Mussmann, Bo Redder
2015-11-01
Generation of multiplanar reformation (MPR) images has become automatic on most modern computed tomography (CT) scanners, potentially increasing the workload of the reporting radiologists. It is not always clear if this increases diagnostic performance in all clinical tasks. To assess detection performance using only coronal multiplanar reformations (MPR) when triaging patients for lung malignancies with CT compared to images in three orthogonal planes, and to evaluate performance comparison of novice and experienced readers. Retrospective study of 63 patients with suspicion of lung cancer, scanned on 64-slice multidetector computed tomography (MDCT) with images reconstructed in three planes. Coronal images were presented to four readers, two novice and two experienced. Readers decided whether the patients were suspicious for malignant disease, and indicated their confidence on a five-point scale. Sensitivity and specificity on per-patient basis was calculated with regards to a reference standard of histological diagnosis, and compared with the original report using McNemar's test. Receiver operating characteristic (ROC) curves were plotted to compare the performance of the four readers, using the area under the curve (AUC) as figure of merit. No statistically significant difference of sensitivity and specificity was found for any of the readers when compared to the original reports. ROC analysis yielded AUCs in the range of 0.92-0.93 for all readers with no significant difference. Inter-rater agreement was substantial (kappa = 0.72). Sensitivity and specificity were comparable to diagnosis using images in three planes. No significant difference was found between experienced and novice readers. © The Foundation Acta Radiologica 2014.
Clinical evaluation of the reproducibility of volume measurements of pulmonary nodules
NASA Astrophysics Data System (ADS)
Wormanns, Dag; Kohl, Gerhard; Klotz, Ernst; Heindel, Walter; Diederich, Stefan
2002-05-01
High reproducibility of volumetric measurements is an important prerequisite for follow-up of small lung nodules in order to differentiate malignant from benign lesions in a lung cancer screening setting. This study was aimed to evaluate the measurement reproducibility of a new software tool for pulmonary nodule volumetry. In an ongoing study, 147 pulmonary nodules (size 1.6-17.5 mm) were examined with low-dose multidetector CT (Siemens Somatom Volume Zoom, 120 kVp, 20 mAs, detector collimation 4x1 mm, normalized pitch 1.75, slice thickness 1.25 mm, reconstruction increment 0.8 mm). Two consecutive low-dose scans covering the whole lung volume were performed within a few minutes. Between both scans, patients were asked to leave the CT scanner, and the second scan was planned independently from the first one. For all visually detected pulmonary nodules with a diameter <20 mm nodule volume was determined on both scans using a software prototype containing segmentation and volumetry algorithms. Results from both scans were compared. Nodule volume differences were determined as difference between the first and second measurement and ranged from 169 to 87%. The performance of the diagnostic test was measured using ROC analysis. For the detection of a volume doubling the area under curve (Az) was 0.98, for a growth of 50% the Az was 0.89. Further refinement of the segmentation algorithm should lead to more consistent measurements in ill-defined nodules. In conclusion, volumetric measurement of pulmonary nodules in multislice CT data sets is a reliable tool for the detection of growth in small pulmonary nodules.
Alford, Sara K; van Beek, Edwin J R; McLennan, Geoffrey; Hoffman, Eric A
2010-04-20
Recent evidence suggests that endothelial dysfunction and pathology of pulmonary vascular responses may serve as a precursor to smoking-associated emphysema. Although it is known that emphysematous destruction leads to vasculature changes, less is known about early regional vascular dysfunction which may contribute to and precede emphysematous changes. We sought to test the hypothesis, via multidetector row CT (MDCT) perfusion imaging, that smokers showing early signs of emphysema susceptibility have a greater heterogeneity in regional perfusion parameters than emphysema-free smokers and persons who had never smoked (NS). Assuming that all smokers have a consistent inflammatory response, increased perfusion heterogeneity in emphysema-susceptible smokers would be consistent with the notion that these subjects may have the inability to block hypoxic vasoconstriction in patchy, small regions of inflammation. Dynamic ECG-gated MDCT perfusion scans with a central bolus injection of contrast were acquired in 17 NS, 12 smokers with normal CT imaging studies (SNI), and 12 smokers with subtle CT findings of centrilobular emphysema (SCE). All subjects had normal spirometry. Quantitative image analysis determined regional perfusion parameters, pulmonary blood flow (PBF), and mean transit time (MTT). Mean and coefficient of variation were calculated, and statistical differences were assessed with one-way ANOVA. MDCT-based MTT and PBF measurements demonstrate globally increased heterogeneity in SCE subjects compared with NS and SNI subjects but demonstrate similarity between NS and SNI subjects. These findings demonstrate a functional lung-imaging measure that provides a more mechanistically oriented phenotype that differentiates smokers with and without evidence of emphysema susceptibility.
Ianniello, Stefania; Di Giacomo, Vincenza; Sessa, Barbara; Miele, Vittorio
2014-09-01
Combined clinical examination and supine chest radiography have shown low accuracy in the assessment of pneumothorax in unstable patients with major chest trauma during the primary survey in the emergency room. The aim of our study was to evaluate the diagnostic accuracy of extended-focused assessment with sonography in trauma (e-FAST), in the diagnosis of pneumothorax, compared with the results of multidetector computed tomography (MDCT) and of invasive interventions (thoracostomy tube placement). This was a retrospective case series involving 368 consecutive unstable adult patients (273 men and 95 women; average age, 25 years; range, 16-68 years) admitted to our hospital's emergency department between January 2011 and December 2012 for major trauma (Injury Severity Score ≥ 15). We evaluated the accuracy of thoracic ultrasound in the detection of pneumothorax compared with the results of MDCT and invasive interventions (thoracostomy tube placement). Institutional review board approval was obtained prior to commencement of this study. Among the 736 lung fields included in the study, 87 pneumothoraces were detected with thoracic CT scans (23.6%). e-FAST detected 67/87 and missed 20 pneumothoraces (17 mild, 3 moderate). The diagnostic performance of ultrasound was: sensitivity 77% (74% in 2011 and 80% in 2012), specificity 99.8%, positive predictive value 98.5%, negative predictive value 97%, accuracy 97.2% (67 true positive; 668 true negative; 1 false positive; 20 false negative); 17 missed mild pneumothoraces were not immediately life-threatening (thickness less than 5 mm). Thoracic ultrasound (e-FAST) is a rapid and accurate first-line, bedside diagnostic modality for the diagnosis of pneumothorax in unstable patients with major chest trauma during the primary survey in the emergency room.
Clarkson, Wesley A; Restrepo, Carlos Santiago; Bauch, Terry D; Rubal, Bernard J
2009-01-01
This study examines the effects of intravenous infusion of adenosine and sublingual nitroglycerin on coronary angiograms obtained by current-generation multidetector computed tomography. We assessed coronary vasodilation at baseline and after intravenous adenosine (140 µg/kg/min) or sublingual nitroglycerin spray (800 µg) in 7 female swine (weight, 40.9 ± 1.4 kg) by using electrocardiogram-gated coronary angiography with a 64-detector scanner (rotation time, 400 ms; 120kV; 400 mA) and intravenous contrast (300 mg/mL iohexol, 4.5 mL/s, 2 mL/kg). Cross-sectional areas of segments in the left anterior descending, circumflex, and right coronary arteries were evaluated in oblique orthogonal views. Images were acquired at an average heart rate of 73 ± 11 beats per minute. Changes in aortic pressure were not significant with nitroglycerin but decreased (approximately 10%) with adenosine. Of the 76 segments analyzed (baseline range, 2 to 39 mm2), 1 distal segment could not be assessed after adenosine. Segment cross-sectional area increased by 11.3% with nitroglycerin but decreased by 9.6% during adenosine infusion. The results of the present study are consistent with the practice of using sublingual nitroglycerin to enhance visualization of epicardial vessels and suggest that intravenous adenosine may hinder coronary artery visualization. This study is the first repeated-measures electrocardiogram-gated CT evaluation to use the same imaging technology to assess changes in coronary cross-sectional area before and after treatment with a vasodilator. The nitroglycerin-associated changes in our swine model were modest in comparison with previously reported human studies. PMID:20034433
NASA Astrophysics Data System (ADS)
Ichihara, Takashi; George, Richard T.; Silva, Caterina; Lima, Joao A. C.; Lardo, Albert C.
2011-02-01
The purpose of this study was to develop a quantitative method for myocardial blood flow (MBF) measurement that can be used to derive accurate myocardial perfusion measurements from dynamic multidetector computed tomography (MDCT) images by using a compartment model for calculating the first-order transfer constant (K1) with correction for the capillary transit extraction fraction (E). Six canine models of left anterior descending (LAD) artery stenosis were prepared and underwent first-pass contrast-enhanced MDCT perfusion imaging during adenosine infusion (0.14-0.21 mg/kg/min). K1 , which is the first-order transfer constant from left ventricular (LV) blood to myocardium, was measured using the Patlak plot method applied to time-attenuation curve data of the LV blood pool and myocardium. The results were compared against microsphere MBF measurements, and the extraction fraction of contrast agent was calculated. K1 is related to the regional MBF as K1=EF, E=(1-exp(-PS/F)), where PS is the permeability-surface area product and F is myocardial flow. Based on the above relationship, a look-up table from K1 to MBF can be generated and Patlak plot-derived K1 values can be converted to the calculated MBF. The calculated MBF and microsphere MBF showed a strong linear association. The extraction fraction in dogs as a function of flow (F) was E=(1-exp(-(0.2532F+0.7871)/F)) . Regional MBF can be measured accurately using the Patlak plot method based on a compartment model and look-up table with extraction fraction correction from K1 to MBF.
Sørgaard, Mathias; Linde, Jesper J; Hove, Jens D; Petersen, Jan R; Jørgensen, Tem B S; Abdulla, Jawdat; Heitmann, Merete; Kragelund, Charlotte; Hansen, Thomas Fritz; Udholm, Patricia M; Pihl, Christian; Kühl, J Tobias; Engstrøm, Thomas; Jensen, Jan Skov; Høfsten, Dan E; Kelbæk, Henning; Kofoed, Klaus F
2016-09-01
Patients admitted with chest pain are a diagnostic challenge because the majority does not have coronary artery disease (CAD). Assessment of CAD with coronary computed tomography angiography (CCTA) is safe, cost-effective, and accurate, albeit with a modest specificity. Stress myocardial computed tomography perfusion (CTP) has been shown to increase the specificity when added to CCTA, without lowering the sensitivity. This article describes the design of a randomized controlled trial, CATCH-2, comparing a clinical diagnostic management strategy of CCTA alone against CCTA in combination with CTP. Patients with acute-onset chest pain older than 50 years and with at least one cardiovascular risk factor for CAD are being prospectively enrolled to this study from 6 different clinical sites since October 2013. A total of 600 patients will be included. Patients are randomized 1:1 to clinical management based on CCTA or on CCTA in combination with CTP, determining the need for further testing with invasive coronary angiography including measurement of the fractional flow reserve in vessels with coronary artery lesions. Patients are scanned with a 320-row multidetector computed tomography scanner. Decisions to revascularize the patients are taken by the invasive cardiologist independently of the study allocation. The primary end point is the frequency of revascularization. Secondary end points of clinical outcome are also recorded. The CATCH-2 will determine whether CCTA in combination with CTP is diagnostically superior to CCTA alone in the management of patients with acute-onset chest pain. Copyright © 2015 Elsevier Inc. All rights reserved.
Chu, Zhi-gang; Yang, Zhi-gang; Dong, Zhi-hui; Chen, Tian-wu; Zhu, Zhi-yu; Deng, Wen; Xiao, Jia-he
2011-10-01
In a massive earthquake, cranio-maxillofacial trauma was common. The present study was to determine the features of cranio-maxillofacial trauma sustained in the massive Sichuan earthquake by multi-detector row computed tomography (MDCT). The study included 221 consecutive patients (123 males and 98 females; age range, 1-83 years; median age, 35 years) with cranio-maxillofacial trauma in the Sichuan earthquake, who underwent cranio-maxillofacial MDCT scans. The image data were retrospectively reviewed focusing on the injuries of the cranio-maxillofacial soft tissue, facial bones and cranium. All patients had soft tissue injuries frequently with foreign bodies. Ninety-seven (43.9%) patients had fractures (1.5 involved sites per patient, range from 1 to 8) including single cranial fractures in 36 (37.1%) cases, single maxillofacial fractures were seen in 48 (49.5%) and cranio-maxillofacial fractures in 13 (13.4%). Single bone fracture was more common than multiple bone fractures (p<0.05). Nasal, ethmoid bones and the orbits were the most commonly involved sites of the craniofacial region. Thirty-eight (17.2%) patients had intracranial injuries, the commonest being subarachnoid haemorrhage and the commonest sites were the temporal and frontal regions. Coexisting intracranial injuries were more common in patients with cranial fractures than in patients with maxillofacial fractures (p<0.05). Our results indicate that the cranio-maxillofacial trauma arising from the massive Sichuan earthquake had some characteristic features, and a significant number of individuals had the potential for combined cranial and maxillofacial injuries, successful management of which required a multidisciplinary approach. Crown Copyright © 2010. Published by Elsevier Ltd. All rights reserved.
Kim, Inwha; Kim, Dae Jung; Kim, Kyoung Ah; Yoon, Sang Wook; Lee, Jong Tae
2014-01-01
To investigate the feasibility and accuracy of multidetector computed tomography (MDCT) angiography for assessment of subsegmental tumor-feeding vessels in transarterial chemoembolization (TACE) of hepatocellular carcinoma (HCC). A total of 23 patients with 36 HCCs who underwent TACE during a 14-month period were enrolled. All patients underwent 3-phase dynamic MDCT within a month before TACE. Arterial phase MDCT images were retrospectively reformatted and analyzed for determination of single subsegmental tumor-feeding vessel using maximum intensity projection (MIP) and volume-rendering technique (VRT). Two radiologists independently assessed and scored the MIP and VRT images using 4-grade visual scores (grade 1, no depiction of tumor-feeding vessel; grade 2, indeterminate tumor-feeding vessel; grade 3, probable tumor-feeding vessel; and grade 4, good depiction of tumor-feeding vessel). The weighted kappa test was used to determine interobserver variability, and Wilcoxon signed rank test was used to differentiate visual scores of each technique. Results of digital subtraction angiography were defined as the criterion standard; therefore, assessment of subsegmental tumor-feeding vessel using MIP or VRT was compared with digital subtraction angiography, and the accuracy of each technique was calculated. Interobserver agreement (weighted kappa, 0.746 on VRT and 0.806 on MIP) was substantial to almost perfect. The visual scores for MIP (mean, 3.64 for reviewer 1 and 3.5 for reviewer 2) were higher than those for VRT (mean, 2.11 for reviewer 1 and 2.22 for reviewer 2; P = 0.000). The accuracy for assessing subsegmental tumor-feeding vessel was 22.2% for VRT and 77.8% for MIP. Multidetector CT angiography using MIP showed good imaging quality and high accuracy for determination of subsegmental tumor-feeding vessels.
Foschi, Claudio; Marangoni, Antonella; D'Antuono, Antonietta; Nardini, Paola; Compri, Monica; Bellavista, Sara; Filippini, Andrea; Bacchi Reggiani, Maria Letizia; Cevenini, Roberto
2014-04-09
We evaluated LGV prevalence and predictors in a high risk population attending a STI Outpatients Clinic in the North of Italy. A total of 108 patients (99 MSM and 9 women), with a history of unsafe anal sexual intercourses, were enrolled. Anorectal swabs and urine samples were tested for Chlamydia trachomatis (CT) DNA detection by Versant CT/GC DNA 1.0 Assay (Siemens Healthcare Diagnostics Terrytown, USA). RFLP analysis was used for CT molecular typing. L2 CT genotype was identified in 13/108 (12%) rectal swabs. All LGV cases were from MSM, declaring high-risk sexual behaviour and complaining anorectal symptoms. Patients first attending the STI Outpatient Clinic received a significant earlier LGV diagnosis than those first seeking care from general practitioners or gastroenterologists (P = 0.0046). LGV prevalence and characteristics found in our population are in agreement with international reports. Statistical analysis showed that LGV positive patients were older (P = 0.0008) and presented more STIs (P = 0.0023) than LGV negative ones, in particular due to syphilis (P < 0.001), HIV (P < 0.001) and HBV (P = 0.001).Multivariate logistic regression analysis revealed that HIV and syphilis infections are strong risk factors for LGV presence (respectively, P = 0.001 and P = 0.010). Even if our results do not provide sufficient evidence to recommend routine screening of anorectal swabs in high-risk population, they strongly suggest to perform CT NAAT tests and genotyping on rectal specimens in presence of ulcerative proctitis in HIV and/or syphilis-positive MSM. In this context, CT DNA detection by Versant CT/GC DNA 1.0 Assay, followed by RFLP analysis for molecular typing demonstrated to be an excellent diagnostic algorithm for LGV identification.
Salisbury, Margaret L; Xia, Meng; Murray, Susan; Bartholmai, Brian J; Kazerooni, Ella A; Meldrum, Catherine A; Martinez, Fernando J; Flaherty, Kevin R
2016-09-01
Idiopathic pulmonary fibrosis (IPF) can be diagnosed confidently and non-invasively when clinical and computed tomography (CT) criteria are met. Many do not meet these criteria due to absence of CT honeycombing. We investigated predictors of IPF and combinations allowing accurate diagnosis in individuals without honeycombing. We utilized prospectively collected clinical and CT data from patients enrolled in the Lung Tissue Research Consortium. Included patients had no honeycombing, no connective tissue disease, underwent diagnostic lung biopsy, and had CT pattern consistent with fibrosing ILD (n = 200). Logistic regression identified clinical and CT variables predictive of IPF. The probability of IPF was assessed at various cut-points of important clinical and CT variables. A multivariable model adjusted for age and gender found increasingly extensive reticular densities (OR 2.93, CI 95% 1.55-5.56, p = 0.001) predicted IPF, while increasing ground glass densities predicted a diagnosis other than IPF (OR 0.55, CI 95% 0.34-0.89, p = 0.02). The model-based probability of IPF was 80% or greater in patients with age at least 60 years and extent of reticular density one-third or more of total lung volume; for patients meeting or exceeding these clinical thresholds the specificity for IPF is 96% (CI 95% 91-100%) with 21 of 134 (16%) biopsies avoided. In patients with suspected fibrotic ILD and absence of CT honeycombing, extent of reticular and ground glass densities predict a diagnosis of IPF. The probability of IPF exceeds 80% in subjects over age 60 years with one-third of total lung having reticular densities. Copyright © 2016 Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
Webb, Christian A.; DeRubeis, Robert J.; Dimidjian, Sona; Hollon, Steven D.; Amsterdam, Jay D.; Shelton, Richard C.
2012-01-01
Objective: Previous research has found that therapist adherence to concrete, problem-focused cognitive therapy (CT) techniques predicts depressive symptom change (e.g., Feeley, DeRubeis, & Gelfand, 1999). More recently, Strunk, DeRubeis, Chui, and Alvarez (2007) demonstrated that in-session evidence of patients' use of CT skills was related to…
CT for all or selective approach? Who really needs a cervical spine CT after blunt trauma.
Duane, Therèse M; Young, Andrew; Mayglothling, Julie; Wilson, Sean P; Weber, William F; Wolfe, Luke G; Ivatury, Rao R
2013-04-01
Computed tomography (CT) is the standard to screen blunt trauma patients for cervical spine (c-spine) fractures, yet there remains a reluctance to scan all trauma team activations because of radiation exposure and cost. The purpose of this study was to identify predictors of positive CT in an effort to decrease future CT use without compromising patient care. We performed a prospective study in which we documented 18 combined NEXUS and Canadian c-spine criteria on 5,182 patients before CT comparing those with and without fractures to identify predictors of injury. Clinical examination was considered positive if any of the 18 criteria were positive. There were 324 patients with a fracture, for an incidence rate of 6.25%. Fracture patients were older (43.89 ± 18.83 years vs. 38.42 ± 17.45 years, p <; 0.0001), with a lower GCS (Glasgow Coma Scale) score (13.49 ± 3.49 vs. 14.32 ± 2.34, p < 0.0001), than nonfracture patients. Clinical examination had a 100% (324 of 324) sensitivity, 0.62% (30 of 4,858) specificity, 6.29% (324 of 5,152) positive predictive value, and 100% (30 of 30) negative predictive value. A total of 77.8% (14 of 18) criteria were significantly associated with fracture by univariate analysis, seven of which were independent predictors of fracture by logistic regression (midline tenderness, GCS score < 15, age ≥65 years, paresthesias, rollover motor vehicle collision, ejected, never in sitting position in emergency department). Evaluation of these seven factors demonstrated a sensitivity of 99.07% (321 of 324), positive predictive value of 6.95% (321 of 4,617), specificity of 11.57% (562 of 4,858), and negative predictive value of 99.47% (562 of 565). Although sensitive, the standard clinical criteria used to determine patients who need radiographs lack specificity. Based on these results, more narrow criteria should be validated in an effort to limit the number of c-spine CTs while not compromising patient care. Prognostic study, level II; diagnostic study, level II.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Choonsik; Kim, Kwang Pyo; Long, Daniel
2011-03-15
Purpose: To develop a computed tomography (CT) organ dose estimation method designed to readily provide organ doses in a reference adult male and female for different scan ranges to investigate the degree to which existing commercial programs can reasonably match organ doses defined in these more anatomically realistic adult hybrid phantomsMethods: The x-ray fan beam in the SOMATOM Sensation 16 multidetector CT scanner was simulated within the Monte Carlo radiation transport code MCNPX2.6. The simulated CT scanner model was validated through comparison with experimentally measured lateral free-in-air dose profiles and computed tomography dose index (CTDI) values. The reference adult malemore » and female hybrid phantoms were coupled with the established CT scanner model following arm removal to simulate clinical head and other body region scans. A set of organ dose matrices were calculated for a series of consecutive axial scans ranging from the top of the head to the bottom of the phantoms with a beam thickness of 10 mm and the tube potentials of 80, 100, and 120 kVp. The organ doses for head, chest, and abdomen/pelvis examinations were calculated based on the organ dose matrices and compared to those obtained from two commercial programs, CT-EXPO and CTDOSIMETRY. Organ dose calculations were repeated for an adult stylized phantom by using the same simulation method used for the adult hybrid phantom. Results: Comparisons of both lateral free-in-air dose profiles and CTDI values through experimental measurement with the Monte Carlo simulations showed good agreement to within 9%. Organ doses for head, chest, and abdomen/pelvis scans reported in the commercial programs exceeded those from the Monte Carlo calculations in both the hybrid and stylized phantoms in this study, sometimes by orders of magnitude. Conclusions: The organ dose estimation method and dose matrices established in this study readily provides organ doses for a reference adult male and female for different CT scan ranges and technical parameters. Organ doses from existing commercial programs do not reasonably match organ doses calculated for the hybrid phantoms due to differences in phantom anatomy, as well as differences in organ dose scaling parameters. The organ dose matrices developed in this study will be extended to cover different technical parameters, CT scanner models, and various age groups.« less
NASA Astrophysics Data System (ADS)
Lavoie, Lindsey K.
The technology of computed tomography (CT) imaging has soared over the last decade with the use of multi-detector CT (MDCT) scanners that are capable of performing studies in a matter of seconds. While the diagnostic information obtained from MDCT imaging is extremely valuable, it is important to ensure that the radiation doses resulting from these studies are at acceptably safe levels. This research project focused on the measurement of organ doses resulting from modern MDCT scanners. A commercially-available dosimetry system was used to measure organ doses. Small dosimeters made of optically-stimulated luminescent (OSL) material were analyzed with a portable OSL reader. Detailed verification of this system was performed. Characteristics studied include energy, scatter, and angular responses; dose linearity, ability to erase the exposed dose and ability to reuse dosimeters multiple times. The results of this verification process were positive. While small correction factors needed to be applied to the dose reported by the OSL reader, these factors were small and expected. Physical, tomographic pediatric and adult phantoms were used to measure organ doses. These phantoms were developed from CT images and are composed of tissue-equivalent materials. Because the adult phantom is comprised of numerous segments, dosimeters were placed in the phantom at several organ locations, and doses to select organs were measured using three clinical protocols: pediatric craniosynostosis, adult brain perfusion and adult cardiac CT angiography (CTA). A wide-beam, 320-slice, volumetric CT scanner and a 64-slice, MDCT scanner were used for organ dose measurements. Doses ranged from 1 to 26 mGy for the pediatric protocol, 1 to 1241 mGy for the brain perfusion protocol, and 2-100 mGy for the cardiac protocol. In most cases, the doses measured on the 64-slice scanner were higher than those on the 320-slice scanner. A methodology to measure organ doses with OSL dosimeters received from CT imaging has been presented. These measurements are especially important in keeping with the ALARA (as low as reasonably achievable) principle. While diagnostic information from CT imaging is valuable and necessary, the dose to patients is always a consideration. This methodology aids in this important task. (Full text of this dissertation may be available via the University of Florida Libraries web site. Please check http://www.uflib.ufl.edu/etd.html)
Yıldırım Poyraz, Nilüfer; Özdemir, Elif; Poyraz, Barış Mustafa; Kandemir, Zuhal; Keskin, Mutlay; Türkölmez, Şeyda
2014-01-01
Objective: The aim of this study was to investigate the relationship between patient characteristics and adenosine-related side-effects during stress myocard perfusion imaging (MPI). The effect of presence of adenosine-related side-effects on the diagnostic value of MPI with integrated SPECT/CT system for coronary artery disease (CAD), was also assessed in this study. Methods: Total of 281 patients (109 M, 172 F; mean age:62.6±10) who underwent standard adenosine stress protocol for MPI, were included in this study. All symptoms during adenosine infusion were scored according to the severity and duration. For the estimation of diagnostic value of adenosine MPI with integrated SPECT/CT system, coronary angiography (CAG) or clinical follow-up were used as gold standard. Results: Total of 173 patients (61.6%) experienced adenosine-related side-effects (group 1); flushing, dyspnea, and chest pain were the most common. Other 108 patients completed pharmacologic stress (PS) test without any side-effects (group 2). Test tolerability were similar in the patients with cardiovascular or airway disease to others, however dyspnea were observed significantly more common in patients with mild airway disease. Body mass index (BMI) ≥30 kg/m2 and age ≤45 years were independent predictors of side-effects. The diagnostic value of MPI was similar in both groups. Sensitivity of adenosine MPI SPECT/CT was calculated to be 86%, specificity was 94% and diagnostic accuracy was 92% for diagnosis of CAD. Conclusion: Adenosine MPI is a feasible and well tolerated method in patients who are not suitable for exercise stress test as well as patients with cardiopulmonary disease. However age ≤45 years and BMI ≥30 kg/m2 are the positive predictors of adenosine-related side-effects, the diagnostic value of adenosine MPI SPECT/CT is not affected by the presence of adenosine related side-effects. PMID:25541932
Park, Wonse; Choi, Ji-Wook; Kim, Jae-Young; Kim, Bong-Chul; Kim, Hyung Jun; Lee, Sang-Hwy
2010-03-01
Paresthesia is a well-known complication of extraction of mandibular third molars (MTMs). The authors evaluated the relationship between paresthesia after MTM extraction and the cortical integrity of the inferior alveolar canal (IAC) by using computed tomography (CT). The authors designed a retrospective cohort study involving participants considered, on the basis of panoramic imaging, to be at high risk of experiencing injury of the inferior alveolar nerve who subsequently underwent CT imaging and extraction of the MTMs. The primary predictor variable was the contact relationship between the IAC and the MTM as viewed on a CT image, classified into three groups: group 1, no contact; group 2, contact between the MTM and the intact IAC cortex; group 3, contact between the MTM and the interrupted IAC cortex. The secondary predictor variable was the number of CT image slices showing the cortical interruption around the MTM. The outcome variable was the presence or absence of postoperative paresthesia after MTM extraction. The study sample comprised 179 participants who underwent MTM extraction (a total of 259 MTMs). Their mean age was 23.6 years, and 85 (47.5 percent) were male. The overall prevalence of paresthesia was 4.2 percent (11 of 259 teeth). The prevalence of paresthesia in group 3 (involving an interrupted IAC cortex) was 11.8 percent (10 of 85 cases), while for group 2 (involving an intact IAC cortex) and group 1 (involving no contact) it was 1.0 percent (1 of 98 cases) and 0.0 percent (no cases), respectively. The frequency of nerve damage increased with the number of CT image slices showing loss of cortical integrity (P=.043). The results of this study indicate that loss of IAC cortical integrity is associated with an increased risk of experiencing paresthesia after MTM extraction.
MAKINO, TAKASHI; HATA, YOSHINOBU; OTSUKA, HAJIME; KOEZUKA, SATOSHI; ISOBE, KAZUTOSHI; TOCHIGI, NOBUMI; SHIRAGA, NOBUYUKI; SHIBUYA, KAZUTOSHI; HOMMA, SAKAE; IYODA, AKIRA
2015-01-01
Intraoperative detection of hilar lymph node metastasis, particularly with extracapsular invasion, may affect the surgical procedure in patients with lung cancer, as the preoperative estimation of hilar lymph node metastasis is unsatisfactory. The aim of this study was to investigate whether fusion positron emission tomography/computed tomography (PET/CT) is able to predict extracapsular invasion of hilar lymph node metastasis. Between April, 2007 and April, 2013, 509 patients with primary lung cancer underwent surgical resection at our institution, among whom 28 patients exhibiting hilar lymph node metastasis (at stations 10 and 11) were enrolled in this study. A maximum lymph node standardized uptake value of >2.5 in PET scans was interpreted as positive. A total of 17 patients had positive preoperative PET/CT findings in their hilar lymph nodes, while the remaining 11 had negative findings. With regard to extracapsular nodal invasion, the PET/CT findings (P=0.0005) and the histological findings (squamous cell carcinoma, P=0.05) were found to be significant predictors in the univariate analysis. In the multivariate analysis, the PET/CT findings were the only independent predictor (P=0.0004). The requirement for extensive pulmonary resection (sleeve lobectomy, bilobectomy or pneumonectomy) was significantly more frequent in the patient group with positive compared with the group with negative PET/CT findings (76 vs. 9%, respectively, P=0.01). Therefore, the PET/CT findings in the hilar lymph nodes were useful for the prediction of extracapsular invasion and, consequently, for the estimation of possible extensive pulmonary resection. PMID:26623046
Makino, Takashi; Hata, Yoshinobu; Otsuka, Hajime; Koezuka, Satoshi; Isobe, Kazutoshi; Tochigi, Nobumi; Shiraga, Nobuyuki; Shibuya, Kazutoshi; Homma, Sakae; Iyoda, Akira
2015-09-01
Intraoperative detection of hilar lymph node metastasis, particularly with extracapsular invasion, may affect the surgical procedure in patients with lung cancer, as the preoperative estimation of hilar lymph node metastasis is unsatisfactory. The aim of this study was to investigate whether fusion positron emission tomography/computed tomography (PET/CT) is able to predict extracapsular invasion of hilar lymph node metastasis. Between April, 2007 and April, 2013, 509 patients with primary lung cancer underwent surgical resection at our institution, among whom 28 patients exhibiting hilar lymph node metastasis (at stations 10 and 11) were enrolled in this study. A maximum lymph node standardized uptake value of >2.5 in PET scans was interpreted as positive. A total of 17 patients had positive preoperative PET/CT findings in their hilar lymph nodes, while the remaining 11 had negative findings. With regard to extracapsular nodal invasion, the PET/CT findings (P=0.0005) and the histological findings (squamous cell carcinoma, P=0.05) were found to be significant predictors in the univariate analysis. In the multivariate analysis, the PET/CT findings were the only independent predictor (P=0.0004). The requirement for extensive pulmonary resection (sleeve lobectomy, bilobectomy or pneumonectomy) was significantly more frequent in the patient group with positive compared with the group with negative PET/CT findings (76 vs. 9%, respectively, P=0.01). Therefore, the PET/CT findings in the hilar lymph nodes were useful for the prediction of extracapsular invasion and, consequently, for the estimation of possible extensive pulmonary resection.
Kalichman, Leonid; Li, Ling; Hunter, David; Been, Ella
2013-01-01
Background Context Few studies have directly evaluated the association of lumbar lordosis and segmental wedging of the vertebral bodies and intervertebral disks with prevalence of spinal degenerative features. Purpose To evaluate the association of CT-evaluated lumbar lordosis, segmental wedging of the vertebral bodies and that of the intervertebral disks with various spinal degeneration features. Study design This cross-sectional study was a nested project to the Framingham Heart Study. Sample A random consecutive subset of 191 participants chosen from the 3590 participants enrolled in the Framingham Heart Study who underwent multi-detector CT to assess aortic calcification. Outcome Measures Physiologic Measures Dichotomous variables indicating the presence of intervertebral disc narrowing, facet joint osteoarthritis, spondylolysis, spondylolisthesis and spinal stenosis and density (in Hounsfield units) of multifidus and erector spinae muscles were evaluated on supine CT, as well as the lordosis angle (LA) and the wedging of the vertebral bodies and intervertebral disks. Sum of vertebral bodies wedging (ΣB) and sum of intervertebral discs wedging (ΣD) were used in analyses. Methods Mean values (±SD) of LA, ΣB and ΣD were calculated in males and females and compared using the t-test. Mean values (±SD) of LA, ΣB and ΣD in 4 age groups: <40, 40–49, 50–59 and 60+ years were calculated. We tested the linear relationship between LA, ΣB and ΣD and age groups. We evaluated the association between each spinal degeneration feature and LA, ΣB and ΣD using multiple logistic regression analysis where studied degeneration features were the dependent variable and all LA, ΣB and ΣD (separately) as well as age, sex, and BMI were independent predictors. Results LA was slightly lower than the normal range for standing individuals, and no difference was found between males and females (p=0.4107). However, the sex differences in sum of vertebral bodies wedging (ΣB) and sum of intervertebral discs wedging (ΣD) were statistically significant (0.0001 and 0.001, respectively). Females exhibit more dorsal wedging of the vertebral bodies and less dorsal wedging of the intervertebral discs than do males. All these parameters showed no association (p>0.05) with increasing age. LA showed statistically significant association with presence of spondylolysis (OR(95%CI): 1.08(1.02–1.14)) and with density of multifidus (1.06 (1.01–1.11). as well as a marginally significant association with isthmic spondylolisthesis (1.07(1.00–1.14). ΣB showed a positive association with degenerative spondylolisthesis and disc narrowing ((1.14(1.06–1.23) and 1.04 (1.00–1.08), correspondingly), whereas ΣD showed negative one (0.93(0.87–0.98) and (0.93(0.89–0.97), correspondingly). Conclusions Significant associations were found between lumbar lordosis evaluated in supine position and segmental wedging of the vertebral bodies and intervertebral disks and prevalence of spondylolysis and spondylolisthesis. Additional studies are needed, to evaluate the association between spondylolysis, isthmic and degenerative spondylolisthesis and vertebral and disc wedging at segmental level. PMID:21474082
Predictors of malignancy in patients with pheochromocytomas/paragangliomas: Asian Indian experience
Sarathi, Vijaya; Kasaliwal, Rajeev; Pandit, Reshma; Goroshi, Manjunath; Malhotra, Gaurav; Dalvi, Abhay; Bakshi, Ganesh; Bhansali, Anil; Rajput, Rajesh; Shivane, Vyankatesh; Lila, Anurag; Bandgar, Tushar; Shah, Nalini S
2016-01-01
Background and aims Malignant transformation of pheochromocytomas/paragangliomas (PCC/PGL) is a rare occurrence, and predictive factors for the same are not well understood. This study aims to identify the predictors of malignancy in patients with PCC/PGL. Materials and methods We performed a retrospective analysis of 142 patients with either PCC or PGL registered at our institute between 2000 and 2015. Records were evaluated for clinical parameters like age, gender, familial/syndromic presentation, symptomatic presentation, biochemistry, size, number and location of tumours and presence of metastases and mode of its diagnosis. Results Twenty patients were found to have metastases; 13 had metastases at diagnosis and seven during follow-up. Metastases were detected by radiology (CT-neck to pelvis) in 11/20 patients (5/13 synchronous and 6/7 metachronous), 131I-metaiodobenzylguanidine in five (2/12 synchronous and 3/6 metachronous) patients and 18F-flurodeoxyglucose PET/CT in 15 (12/12 synchronous and 3/3 metachronous) patients. Malignant tumours were significantly larger than benign tumours (8.3 ± 4.1 cm, range: 3–22 cm vs 5.7 ± 2.3 cm, range: 2–14 cm, P = 0.0001) and less frequently metanephrine secreting. On linear regression analysis, tumour size and lack of metanephrine secretion were the independent predictors of malignancy. Conclusions Patients with primary tumour size >5.7 cm and lack of metanephrine secretory status should be evaluated for possible malignancy not only at diagnosis but also in the postoperative period. As compared to CT and 131I-MIBG scan, 18F-flurodeoxyglucose PET/CT analyses are better (sensitivity: 100%) for the diagnosis of metastases in our study. PMID:27852633
Puig, Josep; Blasco, Gerard; Daunis-i-Estadella, Pepus; van Eendendburg, Cecile; Carrillo-García, María; Aboud, Carlos; Hernández-Pérez, María; Serena, Joaquín; Biarnés, Carles; Nael, Kambiz; Liebeskind, David S.; Thomalla, Götz; Menon, Bijoy K.; Demchuk, Andrew; Wintermark, Max; Pedraza, Salvador
2017-01-01
Objective Blood-brain barrier (BBB) permeability has been proposed as a predictor of hemorrhagic transformation (HT) after tissue plasminogen activator (tPA) administration; however, the reliability of perfusion computed tomography (PCT) permeability imaging for predicting HT is uncertain. We aimed to determine the performance of high-permeability region size on PCT (HPrs-PCT) in predicting HT after intravenous tPA administration in patients with acute stroke. Methods We performed a multimodal CT protocol (non-contrast CT, PCT, CT angiography) to prospectively study patients with middle cerebral artery occlusion treated with tPA within 4.5 hours of symptom onset. HT was graded at 24 hours using the European-Australasian Acute Stroke Study II criteria. ROC curves selected optimal volume threshold, and multivariate logistic regression analysis identified predictors of HT. Results The study included 156 patients (50% male, median age 75.5 years). Thirty-seven (23,7%) developed HT [12 (7,7%), parenchymal hematoma type 2 (PH-2)]. At admission, patients with HT had lower platelet values, higher NIHSS scores, increased ischemic lesion volumes, larger HPrs-PCT, and poorer collateral status. The negative predictive value of HPrs-PCT at a threshold of 7mL/100g/min was 0.84 for HT and 0.93 for PH-2. The multiple regression analysis selected HPrs-PCT at 7mL/100g/min combined with platelets and baseline NIHSS score as the best model for predicting HT (AUC 0.77). HPrs-PCT at 7mL/100g/min was the only independent predictor of PH-2 (OR 1, AUC 0.68, p = 0.045). Conclusions HPrs-PCT can help predict HT after tPA, and is particularly useful in identifying patients at low risk of developing HT. PMID:29182658
Lumbar spine: pretest predictability of CT findings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giles, D.J.; Thomas, R.J.; Osborn, A.G.
Demographic and symptomatic data gathered from 460 patients referred for lumbosacral CT examinations were analyzed to determine if the prescan probability of normal or abnormal findings could be predicted accurately. The authors were unable to predict the presence of herniated disk on the basis of patient-supplied data alone. Age was the single most significant predictor of an abnormality and was sharply related to degenerative disease and spinal stenosis.
A Multidisciplinary Evaluation of Traumatic Brain Injury: Early Predictors of Outcome
2007-04-01
undergoing an acceleration/deceleration movement (i.e., whiplash ) without direct external trauma to the head . Computed tomography (CT...mild head injury. J Neurol Neurosurg Psychiatry. 1985;48:137-140. Geurts ACH , Ribbers GM, Knoop JA, van Limbeek J. Identification of static and...boney) Injury 30 Facial Injury 13 Skull Fracture/ Head CT Findings 7 Symptoms (i.e. dizziness, nausea, vomiting) 10 Past Medical History 6 The NBM
DOE Office of Scientific and Technical Information (OSTI.GOV)
Choi, W; Wang, J; Lu, W
Purpose: To identify the effective quantitative image features (radiomics features) for prediction of response, survival, recurrence and metastasis of hepatocellular carcinoma (HCC) in radiotherapy. Methods: Multiphase contrast enhanced liver CT images were acquired in 16 patients with HCC on pre and post radiation therapy (RT). In this study, arterial phase CT images were selected to analyze the effectiveness of image features for the prediction of treatment outcome of HCC to RT. Response evaluated by RECIST criteria, survival, local recurrence (LR), distant metastasis (DM) and liver metastasis (LM) were examined. A radiation oncologist manually delineated the tumor and normal liver onmore » pre and post CT scans, respectively. Quantitative image features were extracted to characterize the intensity distribution (n=8), spatial patterns (texture, n=36), and shape (n=16) of the tumor and liver, respectively. Moreover, differences between pre and post image features were calculated (n=120). A total of 360 features were extracted and then analyzed by unpaired student’s t-test to rank the effectiveness of features for the prediction of response. Results: The five most effective features were selected for prediction of each outcome. Significant predictors for tumor response and survival are changes in tumor shape (Second Major Axes Length, p= 0.002; Eccentricity, p=0.0002), for LR, liver texture (Standard Deviation (SD) of High Grey Level Run Emphasis and SD of Entropy, both p=0.005) on pre and post CT images, for DM, tumor texture (SD of Entropy, p=0.01) on pre CT image and for LM, liver (Mean of Cluster Shade, p=0.004) and tumor texture (SD of Entropy, p=0.006) on pre CT image. Intensity distribution features were not significant (p>0.09). Conclusion: Quantitative CT image features were found to be potential predictors of the five endpoints of HCC in RT. This work was supported in part by the National Cancer Institute Grant R01CA172638.« less
Ghaneh, Paula; Hanson, Robert; Titman, Andrew; Lancaster, Gill; Plumpton, Catrin; Lloyd-Williams, Huw; Yeo, Seow Tien; Edwards, Rhiannon Tudor; Johnson, Colin; Abu Hilal, Mohammed; Higginson, Antony P; Armstrong, Tom; Smith, Andrew; Scarsbrook, Andrew; McKay, Colin; Carter, Ross; Sutcliffe, Robert P; Bramhall, Simon; Kocher, Hemant M; Cunningham, David; Pereira, Stephen P; Davidson, Brian; Chang, David; Khan, Saboor; Zealley, Ian; Sarker, Debashis; Al Sarireh, Bilal; Charnley, Richard; Lobo, Dileep; Nicolson, Marianne; Halloran, Christopher; Raraty, Michael; Sutton, Robert; Vinjamuri, Sobhan; Evans, Jonathan; Campbell, Fiona; Deeks, Jon; Sanghera, Bal; Wong, Wai-Lup; Neoptolemos, John P
2018-02-01
Pancreatic cancer diagnosis and staging can be difficult in 10-20% of patients. Positron emission tomography (PET)/computed tomography (CT) adds precise anatomical localisation to functional data. The use of PET/CT may add further value to the diagnosis and staging of pancreatic cancer. To determine the incremental diagnostic accuracy and impact of PET/CT in addition to standard diagnostic work-up in patients with suspected pancreatic cancer. A multicentre prospective diagnostic accuracy and clinical value study of PET/CT in suspected pancreatic malignancy. Patients with suspected pancreatic malignancy. All patients to undergo PET/CT following standard diagnostic work-up. The primary outcome was the incremental diagnostic value of PET/CT in addition to standard diagnostic work-up with multidetector computed tomography (MDCT). Secondary outcomes were (1) changes in patients' diagnosis, staging and management as a result of PET/CT; (2) changes in the costs and effectiveness of patient management as a result of PET/CT; (3) the incremental diagnostic value of PET/CT in chronic pancreatitis; (4) the identification of groups of patients who would benefit most from PET/CT; and (5) the incremental diagnostic value of PET/CT in other pancreatic tumours. Between 2011 and 2013, 589 patients with suspected pancreatic cancer underwent MDCT and PET/CT, with 550 patients having complete data and in-range PET/CT. Sensitivity and specificity for the diagnosis of pancreatic cancer were 88.5% and 70.6%, respectively, for MDCT and 92.7% and 75.8%, respectively, for PET/CT. The maximum standardised uptake value (SUV max. ) for a pancreatic cancer diagnosis was 7.5. PET/CT demonstrated a significant improvement in relative sensitivity ( p = 0.01) and specificity ( p = 0.023) compared with MDCT. Incremental likelihood ratios demonstrated that PET/CT significantly improved diagnostic accuracy in all scenarios ( p < 0.0002). PET/CT correctly changed the staging of pancreatic cancer in 56 patients ( p = 0.001). PET/CT influenced management in 250 (45%) patients. PET/CT stopped resection in 58 (20%) patients who were due to have surgery. The benefit of PET/CT was limited in patients with chronic pancreatitis or other pancreatic tumours. PET/CT was associated with a gain in quality-adjusted life-years of 0.0157 (95% confidence interval -0.0101 to 0.0430). In the base-case model PET/CT was seen to dominate MDCT alone and is thus highly likely to be cost-effective for the UK NHS. PET/CT was seen to be most cost-effective for the subgroup of patients with suspected pancreatic cancer who were thought to be resectable. PET/CT provided a significant incremental diagnostic benefit in the diagnosis of pancreatic cancer and significantly influenced the staging and management of patients. PET/CT had limited utility in chronic pancreatitis and other pancreatic tumours. PET/CT is likely to be cost-effective at current reimbursement rates for PET/CT to the UK NHS. This was not a randomised controlled trial and therefore we do not have any information from patients who would have undergone MDCT only for comparison. In addition, there were issues in estimating costs for PET/CT. Future work should evaluate the role of PET/CT in intraductal papillary mucinous neoplasm and prognosis and response to therapy in patients with pancreatic cancer. Current Controlled Trials ISRCTN73852054 and UKCRN 8166. The National Institute for Health Research Health Technology Assessment programme.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Xinhua; Zhang, Da; Liu, Bob
2013-08-15
Purpose: AAPM Task Group 111 proposed to measure the equilibrium dose-pitch product D-caret{sub eq} for scan modes involving table translation and the midpoint dose D{sub L}(0) for stationary-table modes on the central and peripheral axes of sufficiently long (e.g., at least 40 cm) phantoms. This paper presents an alternative approach to calculate both metrics using the measurements of scanning the standard computed tomographic (CT) dosimetry phantoms on CT scanners.Methods: D-caret{sub eq} was calculated from CTDI{sub 100} and ε(CTDI{sub 100}) (CTDI{sub 100} efficiency), and D{sub L}(0) was calculated from D-caret{sub eq} and the approach to equilibrium function H(L) =D{sub L}(0)/D{sub eq},more » where D{sub eq} was the equilibrium dose. CTDI{sub 100} may be directly obtained from several sources (such as medical physicist's CT scanner performance evaluation or the IMPACT CT patient dosimetry calculator), or be derived from CTDI{sub Vol} using the central to peripheral CTDI{sub 100} ratio (R{sub 100}). The authors have provided the required ε(CTDI{sub 100}) and H(L) data in two previous papers [X. Li, D. Zhang, and B. Liu, Med. Phys. 39, 901–905 (2012); and ibid. 40, 031903 (10pp.) (2013)]. R{sub 100} was assessed for a series of GE, Siemens, Philips, and Toshiba CT scanners with multiple settings of scan field of view, tube voltage, and bowtie filter.Results: The calculated D{sub L}(0) and D{sub L}(0)/D{sub eq} in PMMA and water cylinders were consistent with the measurements on two GE CT scanners (LightSpeed 16 and VCT) by Dixon and Ballard [Med. Phys. 34, 3399–3413 (2007)], the measurements on a Siemens CT scanner (SOMATOM Spirit Power) by Descamps et al. [J. Appl. Clin. Med. Phys. 13, 293–302 (2012)], and the Monte Carlo simulations by Boone [Med. Phys. 36, 4547–4554 (2009)].Conclusions: D-caret{sub eq} and D{sub L}(0) can be calculated using the alternative approach. The authors have provided the required ε(CTDI{sub 100}) and H(L) data in two previous papers. R{sub 100} is presented for a majority of multidetector CT scanners currently on the market, and can be easily assessed for other CT scanners or operating conditions not covered in this study. The central to peripheral D{sub eq} ratio is about 1.50 and 1.12 times of R{sub 100} for the 32- and 16-cm diameter PMMA phantom, respectively.« less
Yun, Chun-Ho; Schlett, Christopher L; Rogers, Ian S; Truong, Quynh A; Toepker, Michael; Donnelly, Patrick; Brady, Thomas J; Hoffmann, Udo; Bamberg, Fabian
2009-08-01
The aim of the study was to assess differences in the presence, extent, and composition of coronary atherosclerotic plaque burden as detected by coronary multidetector computed tomography (MDCT) between patients with and without diabetes mellitus. We compared coronary atherosclerotic plaques (any plaque, calcified [CAP], non-calcified [NCAP, and mixed plaque [MCAP
Mori, S; Endo, M; Kohno, R; Minohara, S
2006-09-01
Conventional respiratory-gated CT and four-dimensional CT (4DCT) are disadvantaged by their low temporal resolution, which results in the inclusion of anatomic motion-induced artefacts. These represent a significant source of error both in radiotherapy treatment planning for the thorax and upper abdomen and in diagnostic procedures. In particular, temporal resolution and image quality are vitally important to accurate diagnosis and the minimization of planning target volume margin due to respiratory motion. To improve both temporal resolution and signal-to-noise ratio (SNR), we developed a respiratory-correlated segment reconstruction method (RS) and adapted it to the Feldkamp-Davis-Kress algorithm (FDK) with a 256 multidetector row CT (256MDCT). The 256MDCT scans approximately 100 mm in the craniocaudal direction with a 0.5 mm slice thickness in one rotation. Data acquisition for the RS-FDK relies on the assistance of a respiratory sensing system operating in cine scan mode (continuous axial scan with the table stationary). We evaluated the RS-FDK for volume accuracy and image noise in a phantom study with the 256MDCT and compared results with those for a full scan (FS-FDK), which is usually employed in conventional 4DCT and in half scan (HS-FDK). Results showed that the RS-FDK gave a more accurate volume than the others and had the same SNR as the FS-FDK. In a subsequent animal study, we demonstrated a practical sorting process for projection data which was unaffected by variations in respiratory period, and found that the RS-FDK gave the clearest visualization among the three algorithms of the margins of the liver and pulmonary vessels. In summary, the RS-FDK algorithm provides multi-phase images with higher temporal resolution and better SNR. This method should prove useful when combined with new radiotherapeutic and diagnostic techniques.
NASA Astrophysics Data System (ADS)
Jeon, P.-H.; Lee, C.-L.; Kim, D.-H.; Lee, Y.-J.; Jeon, S.-S.; Kim, H.-J.
2014-03-01
Multi-detector computed tomography (MDCT) can be used to easily and rapidly perform numerous acquisitions, possibly leading to a marked increase in the radiation dose to individual patients. Technical options dedicated to automatically adjusting the acquisition parameters according to the patient's size are of specific interest in pediatric radiology. A constant tube potential reduction can be achieved for adults and children, while maintaining a constant detector energy fluence. To evaluate radiation dose, the weighted CT dose index (CTDIw) was calculated based on the CT dose index (CTDI) measured using an ion chamber, and image noise and image contrast were measured from a scanned image to evaluate image quality. The dose-weighted contrast-to-noise ratio (CNRD) was calculated from the radiation dose, image noise, and image contrast measured from a scanned image. The noise derivative (ND) is a quality index for dose efficiency. X-ray spectra with tube voltages ranging from 80 to 140 kVp were used to compute the average photon energy. Image contrast and the corresponding contrast-to-noise ratio (CNR) were determined for lesions of soft tissue, muscle, bone, and iodine relative to a uniform water background, as the iodine contrast increases at lower energy (i.e., k-edge of iodine is 33 keV closer to the beam energy) using mixed water-iodine contrast normalization (water 0, iodine 25, 100, 200, and 1000 HU, respectively). The proposed values correspond to high quality images and can be reduced if only high-contrast organs are assessed. The potential benefit of lowering the tube voltage is an improved CNRD, resulting in a lower radiation dose and optimization of image quality. Adjusting the tube potential in abdominal CT would be useful in current pediatric radiography, where the choice of X-ray techniques generally takes into account the size of the patient as well as the need to balance the conflicting requirements of diagnostic image quality and radiation dose optimization.
Low agreement of visual rating for detailed quantification of pulmonary emphysema in whole-lung CT.
Mascalchi, Mario; Diciotti, Stefano; Sverzellati, Nicola; Camiciottoli, Gianna; Ciccotosto, Cesareo; Falaschi, Fabio; Zompatori, Maurizio
2012-02-01
Multidetector spiral computed tomography (CT) has opened the possibility of quantitative evaluation of emphysema extent in the whole lung. Visual assessment can be used for such a purpose, but its reproducibility has not been established. To assess agreement of detailed assessment of pulmonary emphysema on whole-lung CT using a visual scale. Thirty patients with chronic obstructive pulmonary disease underwent whole-lung inspiratory CT. Four chest radiologists rated the same 22 ± 2 thin sections using a visual scale which defines a range of emphysema extent between 0 and 100. Two of them repeated the rating two months later. Inter- and intra-operator agreement was evaluated with the Bland and Altman method. In addition, the percentage of emphysema at -950 Hounsfield units in the whole lung was determined using fully automated commercially available software for 3D densitometry. In three of six operator pairs and in one of two intra-operator pairs the Kendall τ test showed a significant correlation between the difference and the average magnitude of visual scores. Among different operators the half-width of 95% limits of agreement (95% LoA) was wide ranging between a score of 14.2-27.7 for an average visual score of 20 and between 18.5-36.8 for an average visual score of 80. Within the same operator the half-width of 95% LoA ranged between a score of 10.9-21.0 for an average visual score of 20 and between 25.1-30.1 for an average visual score of 80. The visual scores of the four radiologists were correlated with the results of densitometry (P < 0.001; r = 0.65-0.81). The inter- and intra-operator agreement of detailed assessment of emphysema in the whole lung using a visual scale is low and decreases with increasing emphysema extent.
Tsuruga, Yosuke; Kamiyama, Toshiya; Kamachi, Hirofumi; Shimada, Shingo; Wakayama, Kenji; Orimo, Tatsuya; Kakisaka, Tatsuhiko; Yokoo, Hideki; Taketomi, Akinobu
2016-05-07
To evaluate the usefulness of the functional hepatic resection rate (FHRR) calculated using 3D computed tomography (CT)/(99m)Tc-galactosyl-human serum albumin (GSA) single-photon emission computed tomography (SPECT) fusion imaging for surgical decision making. We enrolled 57 patients who underwent bi- or trisectionectomy at our institution between October 2013 and March 2015. Of these, 26 patients presented with hepatocellular carcinoma, 12 with hilar cholangiocarcinoma, six with intrahepatic cholangiocarcinoma, four with liver metastasis, and nine with other diseases. All patients preoperatively underwent three-phase dynamic multidetector CT and (99m)Tc-GSA scintigraphy. We compared the parenchymal hepatic resection rate (PHRR) with the FHRR, which was defined as the resection volume counts per total liver volume counts on 3D CT/(99m)Tc-GSA SPECT fusion images. In total, 50 patients underwent bisectionectomy and seven underwent trisectionectomy. Biliary reconstruction was performed in 15 patients, including hepatopancreatoduodenectomy in two. FHRR and PHRR were 38.6 ± 19.9 and 44.5 ± 16.0, respectively; FHRR was strongly correlated with PHRR. The regression coefficient for FHRR on PHRR was 1.16 (P < 0.0001). The ratio of FHRR to PHRR for patients with preoperative therapies (transcatheter arterial chemoembolization, radiation, radiofrequency ablation, etc.), large tumors with a volume of > 1000 mL, and/or macroscopic vascular invasion was significantly smaller than that for patients without these factors (0.73 ± 0.19 vs 0.82 ± 0.18, P < 0.05). Postoperative hyperbilirubinemia was observed in six patients. Major morbidities (Clavien-Dindo grade ≥ 3) occurred in 17 patients (29.8%). There was no case of surgery-related death. Our results suggest that FHRR is an important deciding factor for major hepatectomy, because FHRR and PHRR may be discrepant owing to insufficient hepatic inflow and congestion in patients with preoperative therapies, macroscopic vascular invasion, and/or a tumor volume of > 1000 mL.
Managing incidental findings on abdominal CT: white paper of the ACR incidental findings committee.
Berland, Lincoln L; Silverman, Stuart G; Gore, Richard M; Mayo-Smith, William W; Megibow, Alec J; Yee, Judy; Brink, James A; Baker, Mark E; Federle, Michael P; Foley, W Dennis; Francis, Isaac R; Herts, Brian R; Israel, Gary M; Krinsky, Glenn; Platt, Joel F; Shuman, William P; Taylor, Andrew J
2010-10-01
As multidetector CT has come to play a more central role in medical care and as CT image quality has improved, there has been an increase in the frequency of detecting "incidental findings," defined as findings that are unrelated to the clinical indication for the imaging examination performed. These "incidentalomas," as they are also called, often confound physicians and patients with how to manage them. Although it is known that most incidental findings are likely benign and often have little or no clinical significance, the inclination to evaluate them is often driven by physician and patient unwillingness to accept uncertainty, even given the rare possibility of an important diagnosis. The evaluation and surveillance of incidental findings have also been cited as among the causes for the increased utilization of cross-sectional imaging. Indeed, incidental findings may be serious, and hence, when and how to evaluate them are unclear. The workup of incidentalomas has varied widely by physician and region, and some standardization is desirable in light of the current need to limit costs and reduce risk to patients. Subjecting a patient with an incidentaloma to unnecessary testing and treatment can result in a potentially injurious and expensive cascade of tests and procedures. With the participation of other radiologic organizations listed herein, the ACR formed the Incidental Findings Committee to derive a practical and medically appropriate approach to managing incidental findings on CT scans of the abdomen and pelvis. The committee has used a consensus method based on repeated reviews and revisions of this document and a collective review and interpretation of relevant literature. This white paper provides guidance developed by this committee for addressing incidental findings in the kidneys, liver, adrenal glands, and pancreas. Copyright © 2010 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Methods for radiation detection and characterization using a multiple detector probe
Akers, Douglas William; Roybal, Lyle Gene
2014-11-04
Apparatuses, methods, and systems relating to radiological characterization of environments are disclosed. Multi-detector probes with a plurality of detectors in a common housing may be used to substantially concurrently detect a plurality of different radiation activities and types. Multiple multi-detector probes may be used in a down-hole environment to substantially concurrently detect radioactive activity and contents of a buried waste container. Software may process, analyze, and integrate the data from the different multi-detector probes and the different detector types therein to provide source location and integrated analysis as to the source types and activity in the measured environment. Further, the integrated data may be used to compensate for differential density effects and the effects of radiation shielding materials within the volume being measured.
Sourwine, Mariaileen; Jeudy, Jean; Miller, Brian; Vunnam, Rama; Imanli, Hasan; Mesubi, Olurotimi; Etienne-Mesubi, Martine; See, Vincent; Shorofsky, Stephen; Dickfeld, Timm
2017-10-01
A significant number of ventricular tachycardia circuits are located close to the epicardial surface and are amendable to epicardial ablation. Epicardial fat often interferes with substrate mapping and ablation, though little is known regarding the distribution of fat and its fluctuation with the cardiac cycle. We studied 40 patients who underwent a 64-slice multidetector computed tomography in order to describe patterns of epicardial fat distribution, variation during cardiac cycle, and clinical predictors of epicardial fat. Multiplanar reconstructions were analyzed during systole and diastole in six cross-sections. Epicardial fat thickness was measured across multiple wall segments in each view. Epicardial fat was found to be thicker in areas overlying coronary vasculature (7.8 ± 2.6 mm vs 3.5 ± 0.9 mm, P = 0.001), along with the right ventricular wall (3.9 ± 0.8 mm vs 2.6 ± 0.6 mm, P = 0.001) and the ventricular base (6.1 ± 1.7 mm vs 4.6 ± 1.6 mm, P < 0.01). Epicardial fat thickness increased 27% during systole as compared to diastole (4.9 ± 2.7 mm vs 6.2 ± 3.0 mm, P = 0.04). Variation with cardiac cycle was most evident along the right ventricular wall (3.9 ± 0.8 mm vs 5.0 ± 1.3 mm, P = 0.001) and nonvascular areas (P = 0.001), especially at the ventricular base (3.7 ± 1.1 mm vs 5.3 ± 1.5 mm, P = 0.001). In multivariate logistic regression, we found that age >50 years (P = 0.031) and coronary artery disease (P = 0.023) were statistically correlated with epicardial fat >5-mm thickness and body mass index > 33 (P = 0.052) nearly so. Baseline epicardial fat thickness >5 mm is common in areas typically targeted during epicardial ablation and further increases during the cardiac cycle. Simple clinical characteristics can identify patients with >5 mm epicardial fat in which preprocedural computed tomography imaging and three-dimensional fat map reconstruction may facilitate epicardial ablation. © 2017 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Beck, Christoph; Philipp, Andreas; Jacobeit, Jucundus
2014-05-01
This contribution investigates the relationship between large-scale atmospheric circulation and interannual variations of the standardized precipitation index (SPI) in central Europe. To this end occurrence frequencies of circulation types (CT) derived from a variety of circulation type classifications (CTC) applied to daily sea level pressure (SLP) data and mean circulation indices of vorticity (V), zonality (Z) and meridionality (M) have been utilized as predictors within multiple regression models (MRM) for the estimation of gridded 3-month SPI values over central Europe for the period 1950 to 2010. CTC based MRMs used in the analyses comprise variants concerning the basic method for CT classification, the number of CTs, the size and location of the spatial domain used for CTCs and the exclusive use of CT frequencies or the combined use of CT frequencies and mean circulation indices as predictors. Adequate MRM predictor combinations have been identified by applying stepwise multiple regression analyses within a resampling framework. The performance (robustness) of the resulting MRMs has been quantified based on a leave-one out cross-validation procedure applying several skill scores. Furthermore the relative importance of individual predictors has been estimated for each MRM. From these analyses it can be stated that i.) the consideration of vorticity characteristics within CTCs, ii.) a relatively small size of the spatial domain to which CTCs are applied and iii.) the inclusion of mean circulation indices appear to improve model skill. However model skill exhibits distinct variations between seasons and regions. Whereas promising skill can be stated for the western and northwestern parts of the central European domain only unsatisfactorily skill is reached in the more continental regions and particularly during summer. Thus it can be concluded that the here presented approaches feature the potential for the downscaling of central European drought index variations from large-scale circulation at least for some regions. Further improvements of CTC based approaches may be expected from the optimization of CTCs for explaining the SPI e.g. via the inclusion of additional variables into the classification procedure.
NASA Astrophysics Data System (ADS)
Beck, Christoph; Philipp, Andreas; Jacobeit, Jucundus
2015-08-01
This contribution investigates the relationship between the large-scale atmospheric circulation and interannual variations of the standardized precipitation index (SPI) in Central Europe. To this end, circulation types (CT) have been derived from a variety of circulation type classifications (CTC) applied to daily sea level pressure (SLP) data and mean circulation indices of vorticity ( V), zonality ( Z) and meridionality ( M) have been calculated. Occurrence frequencies of CTs and circulation indices have been utilized as predictors within multiple regression models (MRM) for the estimation of gridded 3-month SPI values over Central Europe, for the period 1950 to 2010. CTC-based MRMs used in the analyses comprise variants concerning the basic method for CT classification, the number of CTs, the size and location of the spatial domain used for CTCs and the exclusive use of CT frequencies or the combined use of CT frequencies and mean circulation indices as predictors. Adequate MRM predictor combinations have been identified by applying stepwise multiple regression analyses within a resampling framework. The performance (robustness) of the resulting MRMs has been quantified based on a leave-one-out cross-validation procedure applying several skill scores. Furthermore, the relative importance of individual predictors has been estimated for each MRM. From these analyses, it can be stated that model skill is improved by (i) the consideration of vorticity characteristics within CTCs, (ii) a relatively small size of the spatial domain to which CTCs are applied and (iii) the inclusion of mean circulation indices. However, model skill exhibits distinct variations between seasons and regions. Whereas promising skill can be stated for the western and northwestern parts of the Central European domain, only unsatisfactory skill is reached in the more continental regions and particularly during summer. Thus, it can be concluded that the presented approaches feature the potential for the downscaling of Central European drought index variations from the large-scale circulation, at least for some regions. Further improvements of CTC-based approaches may be expected from the optimization of CTCs for explaining the SPI, e.g. via the inclusion of additional variables in the classification procedure.
National Trends and Predictors of Locally Advanced Penile Cancer in the United States (1998-2012).
Chipollini, Juan; Chaing, Sharon; Peyton, Charles C; Sharma, Pranav; Kidd, Laura C; Giuliano, Anna R; Johnstone, Peter A; Spiess, Philippe E
2017-08-12
We analyzed the trends in presentation of squamous cell carcinoma (SCC) of the penis and determined the socioeconomic predictors for locally advanced (cT3-cT4) disease in the United States. The National Cancer Database was queried for patients with clinically nonmetastatic penile SCC and staging available from 1998 to 2012. Temporal trends per tumor stage were evaluated, and a multivariable logistic regression model was used to identify predictors for advanced presentation during the study period. A total of 5767 patients with stage ≤ T1-T2 (n = 5423) and T3-T4 (n = 344) disease were identified. Increasing trends were noted in all stages of penile SCC with a greater proportion of advanced cases over time (P = .001). Significant predictors of advanced presentation were age > 55 years, the presence of comorbidities, and Medicaid or no insurance (P < .05 for all). More penile SCC is being detected in the United States. Our results have demonstrated older age, presence of comorbidities, and Medicaid or no insurance as potential barriers to early access of care in the male population. Understanding the current socioeconomic gaps could help guide targeted interventions in vulnerable populations. Copyright © 2017 Elsevier Inc. All rights reserved.
Chest CT scan findings in World Trade Center workers.
de la Hoz, Rafael E; Weber, Jonathan; Xu, Dongming; Doucette, John T; Liu, Xiaoyu; Carson, Deborah A; Celedón, Juan C
2018-03-15
We examined the chest CT scans of 1,453 WTC responders using the International Classification of High-resolution CT for Occupational and Environmental Respiratory Diseases. Univariate and bivariate analyses of potential work-related pleural abnormalities were performed with pre-WTC and WTC-related occupational exposure data, spirometry, demographics and quantitative CT measurements. Logistic regression was used to evaluate occupational predictors of those abnormalities. Chest CT scans were performed first at a median of 6.8 years after 9/11/2001. Pleural abnormalities were the most frequent (21.1%) across all occupational groups In multivariable analyses, significant pre-WTC occupational asbestos exposure, and work as laborer/cleaner were predictive of pleural abnormalities, with prevalence being highest for the Polish subgroup (n = 237) of our population. Continued occupational lung disease surveillance is warranted in this cohort.
Geyer, Lucas L; Körner, Markus; Harrieder, Andreas; Mueck, Fabian G; Deak, Zsuzsanna; Wirth, Stefan; Linsenmaier, Ulrich
2016-01-01
Evaluation of potential dose savings by implementing adaptive statistical iterative reconstruction (ASiR) on a gemstone-based scintillator in a clinical 64-row whole-body CT (WBCT) protocol after multiple trauma. Dose reports of 152 WBCT scans were analysed for two 64-row multidetector CT scanners (Scanners A and B); the main scanning parameters were kept constant. ASiR and a gemstone-based scintillator were used in Scanner B, and the noise index was adjusted (head: 5.2 vs 6.0; thorax/abdomen: 29.0 vs 46.0). The scan length, CT dose index (CTDI) and dose-length product (DLP) were analysed. The estimated mean effective dose was calculated using normalized conversion factors. Student's t-test was used for statistics. Both the mean CTDI (mGy) (Scanner A: 53.8 ± 2.0, 10.3 ± 2.5, 14.4 ± 3.7; Scanner B: 48.7 ± 2.2, 7.1 ± 2.3, 9.1 ± 3.6; p < 0.001, respectively) and the mean DLP (mGy cm) (Scanner A: 1318.9 ± 167.8, 509.3 ± 134.7, 848.8 ± 254.0; Scanner B: 1190.6 ± 172.6, 354.6 ± 128.3, 561.0 ± 246.7; p < 0.001, respectively) for the head, thorax and abdomen were significantly reduced with Scanner B. There was no relevant difference in scan length. The total mean effective dose (mSv) was significantly decreased with Scanner B (24.4 ± 6.0, 17.2 ± 5.8; p < 0.001). The implementation of ASiR and a gemstone-based scintillator allows for significant dose savings in a clinical WBCT protocol. Recent technical developments can significantly reduce radiation dose of WBCT in multiple trauma. Dose reductions of 10-34% can be achieved.
Keil, Sebastian; Bruners, Philipp; Schiffl, Katharina; Sedlmair, Martin; Mühlenbruch, Georg; Günther, Rolf W; Das, Marco; Mahnken, Andreas H
2010-04-01
The purpose of this study was to investigate differences in change of size and CT value between local recurrences and tumor-free areas after CT-guided radiofrequency ablation (RFA) of hepatic metastases during follow-up by means of dedicated software for automatic evaluation of hepatic lesions. Thirty-two patients with 54 liver metastases from breast or colorectal cancer underwent triphasic contrast-enhanced multidetector-row computed tomography (MDCT) to evaluate hepatic metastatic spread and localization before CT-guided RFA and for follow-up after intervention. Sixteen of these patients (65.1 + or - 10.3 years) with 30 metastases stayed tumor-free (group 1), while the other group (n = 16 with 24 metastases; 62.0 + or - 13.8 years) suffered from local recurrent disease (group 2). Applying an automated software tool (SyngoCT Oncology; Siemens Healthcare, Forchheim, Germany), size parameters (volume, RECIST, WHO) and attenuation were measured within the lesions before, 1 day after, and 28 days after RFA treatment. The natural logarithm (ln) of the quotient of the volume 1 day versus 28 days after RFA treament was computed: lnQ1//28/0(volume). Analogously, ln ratios of RECIST, WHO, and attenuation were computed and statistically evaluated by repeated-measures ANOVA. One lesion in group 2 was excluded from further evaluation due to automated missegmentation. Statistically significant differences between the two groups were observed with respect to initial volume, RECIST, and WHO (p < 0.05). Furthermore, ln ratios corresponding to volume, RECIST, and WHO differed significantly between the two groups. Attenuation evaluations showed no significant differences, but there was a trend toward attenuation assessment for the parameter lnQ28/0(attenuation) (p = 0.0527), showing higher values for group 1 (-0.4 + or - 0.3) compared to group 2 (-0.2 + or - 0.2). In conclusion, hepatic metastases and their zone of coagulation necrosis after RFA differed significantly between tumor-free and local-recurrent ablation zones with respect to the corresponding size parameters. A new parameter (lnQ1//28/0(volume/RECIST/WHO/attenuation)) was introduced, which appears to be of prognostic value at early follow-up CT.
Prakash, Priyanka; Kalra, Mannudeep K; Digumarthy, Subba R; Hsieh, Jiang; Pien, Homer; Singh, Sarabjeet; Gilman, Matthew D; Shepard, Jo-Anne O
2010-01-01
To assess radiation dose reduction and image quality for weight-based chest computed tomographic (CT) examination results reconstructed using adaptive statistical iterative reconstruction (ASIR) technique. With local ethical committee approval, weight-adjusted chest CT examinations were performed using ASIR in 98 patients and filtered backprojection (FBP) in 54 weight-matched patients on a 64-slice multidetector CT. Patients were categorized into 3 groups: 60 kg or less (n = 32), 61 to 90 kg (n = 77), and 91 kg or more (n = 43) for weight-based adjustment of noise indices for automatic exposure control (Auto mA; GE Healthcare, Waukesha, Wis). Remaining scan parameters were held constant at 0.984:1 pitch, 120 kilovolts (peak), 40-mm table feed per rotation, and 2.5-mm section thickness. Patients' weight, scanning parameters, and CT dose index volume were recorded. Effective doses (EDs) were estimated. Image noise was measured in the descending thoracic aorta at the level of the carina. Data were analyzed using analysis of variance. Compared with FBP, ASIR was associated with an overall mean (SD) decrease of 27.6% in ED (ASIR, 8.8 [2.3] mSv; FBP, 12.2 [2.1] mSv; P < 0.0001). With the use of ASIR, the ED values were 6.5 (1.8) mSv (28.8% decrease), 7.3 (1.6) mSv (27.3% decrease), and 12.8 (2.3) mSv (26.8% decrease) for the weight groups of 60 kg or less, 61 to 90 kg, and 91 kg or more, respectively, compared with 9.2 (2.3) mSv, 10.0 (2.0) mSv, and 17.4 (2.1) mSv with FBP (P < 0.0001). Despite dose reduction, there was less noise with ASIR (12.6 [2.9] mSv) than with FBP (16.6 [6.2] mSv; P < 0.0001). Adaptive statistical iterative reconstruction helps reduce chest CT radiation dose and improve image quality compared with the conventionally used FBP image reconstruction.
Zuo, Yi-Zhi; Liu, Chao; Liu, Shu-Wei
2013-04-01
To describe the normal imaging appearance of pulmonary intersegmental planes on thoracic computed tomographic (CT) scans and determine the possible reasons related to their visualization in terms of aging and anatomy. The study was approved by the internal ethics review board. Informed consent was obtained. A retrospective review was undertaken of 104 thoracic multidetector CT scans of an older group (>65 years) and younger group (<55 years). The number, location, and appearance rate of intersegmental planes were assessed. Group comparisons were made, and linear regression analysis was used to assess relationships between age and visualization of intersegmental planes. Thirty lung samples (10 × 10 × 10 mm(3)) from autopsy were scanned by using micro-CT. Thicknesses of intersegmental planes were measured. Significant differences of the thickness between visible and invisible intersegmental planes were assessed with the independent t test. In five fetal specimens (17-21 weeks in gestational age), 7.0-T magnetic resonance (MR) imaging was performed to determine the congenital difference of thickness of intersegmental planes. Within the right lung, appearance rates of visible intersegmental planes were 71.2% at S1-S3, 54.8% at S4-S5, and 70.2% at S7-S10. Within the left lung, appearance rates of visible intersegmental planes were 39.4% at S1+2 to S3, 64.4% at S4-S5, 18.3% at S7-S8, and 89.4% at S7-S10. Appearance rates of visible intersegmental planes on thoracic CT scans were not significantly different (P ≥ .38) between younger and older groups. Mean thicknesses of visible and invisible intersegmental planes were 681.3 μm ± 75.3 (standard deviation) and 221.7 μm ± 54.1, respectively. Visible intersegmental planes were significantly thicker than invisible intersegmental planes (P < .05). Visible intersegmental planes were also seen on fetal lung 7.0-T MR images. The thickness of pulmonary intersegmental planes and variation of intersegmental veins were closely related to visualization of intersegmental planes on thoracic CT scans. Aging was excluded as the possible reason. RSNA, 2013
Padole, Atul; Deedar Ali Khawaja, Ranish; Otrakji, Alexi; Zhang, Da; Liu, Bob; Xu, X George; Kalra, Mannudeep K
2016-05-01
The aim of this study was to compare the directly measured and the estimated computed tomography (CT) organ doses obtained from commercial radiation dose-tracking (RDT) software for CT performed with modulated tube current or automatic exposure control (AEC) technique and fixed tube current (mAs). With the institutional review board (IRB) approval, the ionization chambers were surgically implanted in a human cadaver (88 years old, male, 68 kg) in six locations such as liver, stomach, colon, left kidney, small intestine, and urinary bladder. The cadaver was scanned with routine abdomen pelvis protocol on a 128-slice, dual-source multidetector computed tomography (MDCT) scanner using both AEC and fixed mAs. The effective and quality reference mAs of 100, 200, and 300 were used for AEC and fixed mAs, respectively. Scanning was repeated three times for each setting, and measured and estimated organ doses (from RDT software) were recorded (N = 3*3*2 = 18). Mean CTDIvol for AEC and fixed mAs were 4, 8, 13 mGy and 7, 14, 21 mGy, respectively. The most estimated organ doses were significantly greater (P < 0.01) than the measured organ doses for both AEC and fixed mAs. At AEC, the mean estimated organ doses (for six organs) were 14.7 mGy compared to mean measured organ doses of 12.3 mGy. Similarly, at fixed mAs, the mean estimated organ doses (for six organs) were 24 mGy compared to measured organ doses of 22.3 mGy. The differences among the measured and estimated organ doses were higher for AEC technique compared to the fixed mAs for most organs (P < 0.01). The most CT organ doses estimated from RDT software are greater compared to directly measured organ doses, particularly when AEC technique is used for CT scanning. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Ozaki, Kumi; Matsui, Osamu; Gabata, Toshifumi; Kobayashi, Satoshi; Koda, Wataru; Minami, Tetsuya
2013-08-01
Our aim was to retrospectively analyze the location of confluent hepatic fibrosis in relation to the portal and hepatic venous anatomy using multidetector computed tomography (CT) and to clarify the influence of the hepatic venous drainage on confluent fibrosis. The study population consisted of 879 patients diagnosed with cirrhosis: 539 men and 340 women (65.9 ± 10.6 years) and 633 with Child-Pugh class A, 161 with class B, and 85 with class C. The cause of cirrhosis was hepatitis C (n = 528) and hepatitis B (n = 122) virus infection, alcoholism (n = 114), and others (n = 115). The confluent fibrosis was diagnosed using CT images according to previous reports and statistically analyzed (p < 0.05). Thirty-five confluent fibrosis lesions in 30 patients (3.4 %) were identified. The predictive factors were alcoholic cirrhosis [odds ratio (OR), 7.25; p < 0.0001], Child-Pugh class C (OR, 6.95; p < 0.0001), and Child-Pugh class B (OR, 2.91; p < 0.0023). Confluent fibrosis was most frequently seen in the middle hepatic venous drainage area (n = 21) or at the boundary between the medial and anterior segments (n = 17), and each distribution of the location of confluent fibrosis was significantly unequal (p < 0.0001). Confluent fibrosis was most commonly located in the middle hepatic venous drainage area.
CBCT-based bone quality assessment: are Hounsfield units applicable?
Jacobs, R; Singer, S R; Mupparapu, M
2015-01-01
CBCT is a widely applied imaging modality in dentistry. It enables the visualization of high-contrast structures of the oral region (bone, teeth, air cavities) at a high resolution. CBCT is now commonly used for the assessment of bone quality, primarily for pre-operative implant planning. Traditionally, bone quality parameters and classifications were primarily based on bone density, which could be estimated through the use of Hounsfield units derived from multidetector CT (MDCT) data sets. However, there are crucial differences between MDCT and CBCT, which complicates the use of quantitative gray values (GVs) for the latter. From experimental as well as clinical research, it can be seen that great variability of GVs can exist on CBCT images owing to various reasons that are inherently associated with this technique (i.e. the limited field size, relatively high amount of scattered radiation and limitations of currently applied reconstruction algorithms). Although attempts have been made to correct for GV variability, it can be postulated that the quantitative use of GVs in CBCT should be generally avoided at this time. In addition, recent research and clinical findings have shifted the paradigm of bone quality from a density-based analysis to a structural evaluation of the bone. The ever-improving image quality of CBCT allows it to display trabecular bone patterns, indicating that it may be possible to apply structural analysis methods that are commonly used in micro-CT and histology. PMID:25315442
Dudley-Javoroski, S; Petrie, M A; McHenry, C L; Amelon, R E; Saha, P K; Shields, R K
2016-03-01
This study examined the effect of a controlled dose of vibration upon bone density and architecture in people with spinal cord injury (who eventually develop severe osteoporosis). Very sensitive computed tomography (CT) imaging revealed no effect of vibration after 12 months, but other doses of vibration may still be useful to test. The purposes of this report were to determine the effect of a controlled dose of vibratory mechanical input upon individual trabecular bone regions in people with chronic spinal cord injury (SCI) and to examine the longitudinal bone architecture changes in both the acute and chronic state of SCI. Participants with SCI received unilateral vibration of the constrained lower limb segment while sitting in a wheelchair (0.6g, 30 Hz, 20 min, three times weekly). The opposite limb served as a control. Bone mineral density (BMD) and trabecular micro-architecture were measured with high-resolution multi-detector CT. For comparison, one participant was studied from the acute (0.14 year) to the chronic state (2.7 years). Twelve months of vibration training did not yield adaptations of BMD or trabecular micro-architecture for the distal tibia or the distal femur. BMD and trabecular network length continued to decline at several distal femur sub-regions, contrary to previous reports suggesting a "steady state" of bone in chronic SCI. In the participant followed from acute to chronic SCI, BMD and architecture decline varied systematically across different anatomical segments of the tibia and femur. This study supports that vibration training, using this study's dose parameters, is not an effective anti-osteoporosis intervention for people with chronic SCI. Using a high-spatial-resolution CT methodology and segmental analysis, we illustrate novel longitudinal changes in bone that occur after spinal cord injury.
Orgera, G; Monfardini, L; Della Vigna, P; Zhang, L; Bonomo, G; Arnone, P; Padrenostro, M; Orsi, F
2011-08-01
The purpose of this study was to evaluate the safety and efficacy of ultrasound-guided high-intensity focused ultrasound (USgHIFU) for ablation of solid tumours without damaging the surrounding structures. A specific written informed consent was obtained from every patient before treatment. From September 2008 to April 2009, 22 patients with 29 lesions were treated: nine patients with liver and/or soft-tissue metastases from colorectal carcinoma (CRC), six with pancreatic solid lesions, three with liver and/or bone metastases from breast cancer, one with osteosarcoma, one with muscle metastasis from lung cancer, one with iliac metastasis from multiple myeloma and one with abdominal liposarcoma. The mean diameter of tumours was 4.2 cm. All patients were evaluated 1 day, 1 month and 3 months after HIFU treatment by multidetector computed tomography (MDCT), positron-emission tomography (PET)-CT and clinical evaluation. The treatment time and adverse events were recorded. All patients had one treatment. Average treatment and sonication times were, respectively, 162.7 and 37.4 min. PET-CT or/and MDCT showed complete response in 11/13 liver metastases; all bone, soft-tissue and pancreatic lesions were palliated in symptoms, with complete response to PET-CT, MDCT or magnetic resonance imaging (MRI); the liposarcoma was almost completely ablated at MRI. Local oedema was observed in three patients. No other side effects were observed. All patients were discharged 1-3 days after treatment. According to our preliminary experience in a small number of patients, we conclude that HIFU ablation is a safe and feasible technique for locoregional treatment and is effective in pain control.
NASA Astrophysics Data System (ADS)
Dang, H.; Stayman, J. W.; Xu, J.; Sisniega, A.; Zbijewski, W.; Wang, X.; Foos, D. H.; Aygun, N.; Koliatsos, V. E.; Siewerdsen, J. H.
2016-03-01
Intracranial hemorrhage (ICH) is associated with pathologies such as hemorrhagic stroke and traumatic brain injury. Multi-detector CT is the current front-line imaging modality for detecting ICH (fresh blood contrast 40-80 HU, down to 1 mm). Flat-panel detector (FPD) cone-beam CT (CBCT) offers a potential alternative with a smaller scanner footprint, greater portability, and lower cost potentially well suited to deployment at the point of care outside standard diagnostic radiology and emergency room settings. Previous studies have suggested reliable detection of ICH down to 3 mm in CBCT using high-fidelity artifact correction and penalized weighted least-squared (PWLS) image reconstruction with a post-artifact-correction noise model. However, ICH reconstructed by traditional image regularization exhibits nonuniform spatial resolution and noise due to interaction between the statistical weights and regularization, which potentially degrades the detectability of ICH. In this work, we propose three regularization methods designed to overcome these challenges. The first two compute spatially varying certainty for uniform spatial resolution and noise, respectively. The third computes spatially varying regularization strength to achieve uniform "detectability," combining both spatial resolution and noise in a manner analogous to a delta-function detection task. Experiments were conducted on a CBCT test-bench, and image quality was evaluated for simulated ICH in different regions of an anthropomorphic head. The first two methods improved the uniformity in spatial resolution and noise compared to traditional regularization. The third exhibited the highest uniformity in detectability among all methods and best overall image quality. The proposed regularization provides a valuable means to achieve uniform image quality in CBCT of ICH and is being incorporated in a CBCT prototype for ICH imaging.
Erol, Cengiz; Koplay, Mustafa; Olcay, Ayhan; Kivrak, Ali Sami; Ozbek, Seda; Seker, Mehmet; Paksoy, Yahya
2012-11-01
Our aim was to evaluate congenital left ventricular wall abnormalities (clefts, aneurysms and diverticula), describe and illustrate imaging features, discuss terminology problems and determine their prevalence detected by cardiac CT in a single center. Coronary CT angiography images of 2093 adult patients were evaluated retrospectively in order to determine congenital left ventricular wall abnormalities. The incidence of left ventricular clefts (LVC) was 6.7% (141 patients) and statistically significant difference was not detected between the sexes regarding LVC (P=0.5). LVCs were single in 65.2% and multiple in 34.8% of patients. They were located at the basal to mid inferoseptal segment of the left ventricle in 55.4%, the basal to mid anteroseptal segment in 24.1%, basal to mid inferior segment in 17% and septal-apical septal segment in 3.5% of cases. The cleft length ranged from 5 to 22 mm (mean 10.5 mm) and they had a narrow connection with the left ventricle (mean 2.5 mm). They were contractile with the left ventricle and obliterated during systole. Congenital left ventricular septal aneurysm that was located just under the aortic valve was detected in two patients (0.1%). No case of congenital left ventricular diverticulum was detected. Cardiac CT allows us to recognize congenital left ventricular wall abnormalities which have been previously overlooked in adults. LVC is a congenital structural variant of the myocardium, is seen more frequently than previously reported and should be differentiated from aneurysm and diverticulum for possible catastrophic complications of the latter two. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Construction of a multimodal CT-video chest model
NASA Astrophysics Data System (ADS)
Byrnes, Patrick D.; Higgins, William E.
2014-03-01
Bronchoscopy enables a number of minimally invasive chest procedures for diseases such as lung cancer and asthma. For example, using the bronchoscope's continuous video stream as a guide, a physician can navigate through the lung airways to examine general airway health, collect tissue samples, or administer a disease treatment. In addition, physicians can now use new image-guided intervention (IGI) systems, which draw upon both three-dimensional (3D) multi-detector computed tomography (MDCT) chest scans and bronchoscopic video, to assist with bronchoscope navigation. Unfortunately, little use is made of the acquired video stream, a potentially invaluable source of information. In addition, little effort has been made to link the bronchoscopic video stream to the detailed anatomical information given by a patient's 3D MDCT chest scan. We propose a method for constructing a multimodal CT-video model of the chest. After automatically computing a patient's 3D MDCT-based airway-tree model, the method next parses the available video data to generate a positional linkage between a sparse set of key video frames and airway path locations. Next, a fusion/mapping of the video's color mucosal information and MDCT-based endoluminal surfaces is performed. This results in the final multimodal CT-video chest model. The data structure constituting the model provides a history of those airway locations visited during bronchoscopy. It also provides for quick visual access to relevant sections of the airway wall by condensing large portions of endoscopic video into representative frames containing important structural and textural information. When examined with a set of interactive visualization tools, the resulting fused data structure provides a rich multimodal data source. We demonstrate the potential of the multimodal model with both phantom and human data.
The Relationship Between Pulmonary Emphysema and Kidney Function in Smokers
Chandra, Divay; Stamm, Jason A.; Palevsky, Paul M.; Leader, Joseph K.; Fuhrman, Carl R.; Zhang, Yingze; Bon, Jessica; Duncan, Steven R.; Branch, Robert A.; Weissfeld, Joel; Gur, David; Gladwin, Mark T.
2012-01-01
Background: It has been reported that the prevalence of kidney dysfunction may be increased in patients exposed to tobacco with airflow obstruction. We hypothesized that kidney dysfunction would associate with emphysema rather than with airflow obstruction measured by the FEV1. Methods: Five hundred eight current and former smokers completed a chest CT scan, pulmonary function tests, medical questionnaires, and measurement of serum creatinine. Glomerular filtration rates (eGFRs) were estimated using the method of the Chronic Kidney Disease Epidemiology Collaboration. Quantitative determinants of emphysema and airway dimension were measured from multidetector chest CT scans. Results: The mean age was 66 ± 7 years, and mean eGFR was 101 ± 22 mL/min/1.73 m2. Univariate and multivariate analysis showed a significant association between radiographically measured emphysema and eGFR: Participants with 10% more emphysema had an eGFR that was lower by 4.4 mL/min/1.73 m2 (P = .01), independent of airflow obstruction (FEV1), age, sex, race, height, BMI, diabetes mellitus, hypertension, coronary artery disease, patient-reported dyspnea, pack-years of smoking, and current smoking. There was no association between eGFR and either FEV1 or quantitative CT scan measures of airway dimension. Conclusions: More severe emphysema, rather than airflow obstruction, is associated with kidney dysfunction in tobacco smokers, independent of common risk factors for kidney disease. This finding adds to recent observations of associations between emphysema and comorbidities of COPD, including osteoporosis and lung cancer, which are independent of the traditional measure of reduced FEV1. The mechanisms and clinical implications of kidney dysfunction in patients with emphysema need further investigation. PMID:22459775
Rowe, Matthew K; Moore, Peter; Pratap, Jit; Coucher, John; Gould, Paul A; Kaye, Gerald C
2017-05-01
Controversy exists regarding the optimal lead position for chronic right ventricular (RV) pacing. Placing a lead at the RV septum relies upon fluoroscopy assisted by a surface 12-lead electrocardiogram (ECG). We compared the postimplant lead position determined by ECG-gated multidetector contrast-enhanced computed tomography (MDCT) with the position derived from the surface 12-lead ECG. Eighteen patients with permanent RV leads were prospectively enrolled. Leads were placed in the RV septum (RVS) in 10 and the RV apex (RVA) in eight using fluoroscopy with anteroposterior and left anterior oblique 30° views. All patients underwent MDCT imaging and paced ECG analysis. ECG criteria were: QRS duration; QRS axis; positive or negative net QRS amplitude in leads I, aVL, V1, and V6; presence of notching in the inferior leads; and transition point in precordial leads at or after V4. Of the 10 leads implanted in the RVS, computed tomography (CT) imaging revealed seven to be at the anterior RV wall, two at the anteroseptal junction, and one in the true septum. For the eight RVA leads, four were anterior, two septal, and two anteroseptal. All leads implanted in the RVS met at least one ECG criteria (median 3, range 1-6). However, no criteria were specific for septal position as judged by MDCT. Mean QRS duration was 160 ± 24 ms in the RVS group compared with 168 ± 14 ms for RVA pacing (P = 0.38). We conclude that the surface ECG is not sufficiently accurate to determine RV septal lead tip position compared to cardiac CT. © 2017 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Li, Xiang; Samei, Ehsan; DeLong, David M.; Jones, Robert P.; Colsher, James G.; Frush, Donald P.
2008-03-01
The purpose of this study is to evaluate the effect of reduced tube current, as a surrogate for radiation dose, on lung nodule detection in pediatric chest multi-detector CT (MDCT). Normal chest MDCT images of 13 patients aged 1 to 7 years old were used as templates for this study. The original tube currents were between 70 mA and 180 mA. Using proprietary noise addition software, noise was added to the images to create 13 cases at the lowest common mA (i.e. 70 mA), 13 cases at 35 mA (50% reduction), and 13 cases at 17.5 mA (75% reduction). Three copies of each case were made for a total of 117 series for simulated nodule insertion. A technique for three-dimensional simulation of small lung nodules was developed, validated through an observer study, and used to add nodules to the series. Care was taken to ensure that each of three lung zones (upper, middle, lower) contained 0 or 1 nodule. The series were randomized and the presence of a nodule in each lung zone was rated independently and blindly by three pediatric radiologists on a continuous scale between 0 (definitely absent) and 100 (definitely present). Receiver operating characteristic analysis of the data showed no general significant difference in diagnostic accuracy between the reduced mA values and 70 mA, suggesting a potential for dose reduction with preserved diagnostic quality. To our knowledge, this study is the first controlled, systematic, and task-specific assessment of the influence of dose reduction in pediatric chest CT.
Role of virtual bronchoscopy in children with a vegetable foreign body in the tracheobronchial tree.
Behera, G; Tripathy, N; Maru, Y K; Mundra, R K; Gupta, Y; Lodha, M
2014-12-01
Multidetector computed tomography virtual bronchoscopy is a non-invasive diagnostic tool which provides a three-dimensional view of the tracheobronchial airway. This study aimed to evaluate the usefulness of virtual bronchoscopy in cases of vegetable foreign body aspiration in children. The medical records of patients with a history of foreign body aspiration from August 2006 to August 2010 were reviewed. Data were collected regarding their clinical presentation and chest X-ray, virtual bronchoscopy and rigid bronchoscopy findings. Cases of metallic and other non-vegetable foreign bodies were excluded from the analysis. Patients with multidetector computed tomography virtual bronchoscopy showing features of vegetable foreign body were included in the analysis. For each patient, virtual bronchoscopy findings were reviewed and compared with those of rigid bronchoscopy. A total of 60 patients; all children ranging from 1 month to 8 years of age, were included. The mean age at presentation was 2.01 years. Rigid bronchoscopy confirmed the results of multidetector computed tomography virtual bronchoscopy (i.e. presence of foreign body, site of lodgement, and size and shape) in 59 patients. In the remaining case, a vegetable foreign body identified by virtual bronchoscopy was revealed by rigid bronchoscopy to be a thick mucus plug. Thus, the positive predictive value of virtual bronchoscopy was 98.3 per cent. Multidetector computed tomography virtual bronchoscopy is a sensitive and specific diagnostic tool for identifying radiolucent vegetable foreign bodies in the tracheobronchial tree. It can also provide a useful pre-operative road map for rigid bronchoscopy. Patients suspected of having an airway foreign body or chronic unexplained respiratory symptoms should undergo multidetector computed tomography virtual bronchoscopy to rule out a vegetable foreign body in the tracheobronchial tree and avoid general anaesthesia and invasive rigid bronchoscopy.
Gupta, Atul K; Alberico, Ronald A; Litwin, Alan; Kanter, Peter; Grossman, Zachary D
2002-01-01
To demonstrate that gadopentetate dimeglumine is potentially an alternative contrast medium for computed tomographic angiography (CTA). One 12.2-kg Beagle dog was studied as proof of principle; the cervical vessels of three adult human patients were imaged for presurgical planning of the neck. Gadopentetate dimeglumine, 0.5 mol/l (Berlex Laboratories, Wayne, NJ, U.S.A.), a LightSpeed QX/i CT (General Electric Medical Systems, Milwaukee, WI, U.S.A.), and an Ultra Sparc II (SUN Microsystems, Santa Clara, CA, U.S.A.) running Advantage Windows 3.1 (General Electric Medical Systems) were used. Sufficient enhancement for CTA of the thoracic aorta, cervical vessels, and abdominal vessels was produced in the experimental dog, and the cervical vessels were clearly defined in all three patients. In that subset of patients with contraindications to iodinated contrast medium and for whom magnetic resonance angiography is inappropriate, gadopentetate dimeglumine may be an alternative contrast medium for CTA.
Goeree, Ron; Blackhouse, Gord; Bowen, James M; O'Reilly, Daria; Sutherland, Simone; Hopkins, Robert; Chow, Benjamin; Freeman, Michael; Provost, Yves; Dennie, Carole; Cohen, Eric; Marcuzzi, Dan; Iwanochko, Robert; Moody, Alan; Paul, Narinder; Parker, John D
2013-10-01
Conventional coronary angiography (CCA) is the standard diagnostic for coronary artery disease (CAD), but multi-detector computed tomography coronary angiography (CTCA) is a non-invasive alternative. A multi-center coverage with evidence development study was undertaken and combined with an economic model to estimate the cost-effectiveness of CTCA followed by CCA vs CCA alone. Alternative assumptions were tested in patient scenario and sensitivity analyses. CCA was found to dominate CTCA, however, CTCA was relatively more cost-effective in females, in advancing age, in patients with lower pre-test probabilities of CAD, the higher the sensitivity of CTCA and the lower the probability of undergoing a confirmatory CCA following a positive CTCA. RESULTS were very sensitive to alternative patient populations and modeling assumptions. Careful consideration of patient characteristics, procedures to improve the diagnostic yield of CTCA and selective use of CCA following CTCA will impact whether CTCA is cost-effective or dominates CCA.
Nakagawa, Junichiro; Tasaki, Osamu; Watanabe, Yoshiyuki; Azuma, Takeo; Ohnishi, Mitsuo; Ukai, Isao; Tahara, Kenichi; Ogura, Hiroshi; Kuwagata, Yasuyuki; Hamasaki, Toshimitsu; Shimazu, Takeshi
2013-01-01
Electrocardiogram-gated imaging combined with multi-detector row computed tomography (MDCT) has reduced cardiac motion artifacts, but it was not practical in the emergency setting. The purpose of this study was to evaluate the ability of a high-pitch, 128-slice dual-source CT (DSCT) scanner to reduce motion artifacts in patients admitted to the emergency room. This study comprised 100 patients suspected of having thoracic aorta lesions. We examined 47 patients with the 128-slice DSCT scanner (DSCT group), and 53 patients were examined with a 64-slice MDCT scanner (MDCT group). Six anatomic areas in the thoracic aorta were evaluated. Computed tomography images in the DSCT group were distinct, and significant differences were observed in images of all areas between the 2 groups except for the descending aorta. The high-pitch DSCT scanner can reduce motion artifacts of the thoracic aorta and enable radiological diagnosis even in patients with tachycardia and without breath hold.
Herts, Brian R; Schneider, Erika; Obuchowski, Nancy; Poggio, Emilio; Jain, Anil; Baker, Mark E
2009-08-01
The objectives of our study were to develop a model to predict the probability of reduced renal function after outpatient contrast-enhanced CT (CECT)--based on patient age, sex, and race and on serum creatinine level before CT or directly based on estimated glomerular filtration rate (GFR) before CT--and to determine the relationship between patients with changes in creatinine level that characterize contrast-induced nephropathy and patients with reduced GFR after CECT. Of 5,187 outpatients who underwent CECT, 963 (18.6%) had serum creatinine levels obtained within 6 months before and 4 days after CECT. The estimated GFR was calculated before and after CT using the four-variable Modification of Diet in Renal Disease (MDRD) Study equation. Pre-CT serum creatinine level, age, race, sex, and pre-CT estimated GFR were tested using multiple-variable logistic regression models to determine the probability of having an estimated GFR of < 60 and < 45 mL/min/1.73 m(2) after CECT. Two thirds of the patients were used to create and one third to test the models. We also determined discordance between patients who met standard definitions of contrast-induced nephropathy and those with a reduced estimated GFR after CECT. Significant (p < 0.002) predictors for a post-CT estimated GFR of < 60 mL/min/1.73 m(2) were age, race, sex, pre-CT serum creatinine level, and pre-CT estimated GFR. Sex, serum creatinine level, and pre-CT estimated GFR were significant factors (p < 0.001) for predicting a post-CT estimated GFR of < 45 mL/min/1.73 m(2). The probability is [exp(y) / (1 + exp(y))], where y = 6.21 - (0.10 x pre-CT estimated GFR) for an estimated GFR of < 60 mL/min/1.73 m(2), and y = 3.66 - (0.087 x pre-CT estimated GFR) for an estimated GFR of < 45 mL/min/1.73 m(2). A discrepancy between those who met contrast-induced nephropathy criteria by creatinine changes and those with a post-CT estimated GFR of < 60 mL/min/1.73 m(2) was detected in 208 of the 963 patients (21.6%). The probability of a reduced estimated GFR after CECT can be predicted by the pre-CT estimated GFR using the four-variable MDRD equation. Furthermore, standard criteria for contrast-induced nephropathy are poor predictors of poor renal function after CECT. Criteria need to be established for what is an acceptable risk to manage patients undergoing CECT.
Wang, Hanfeng; Gu, Liangyou; Jia, Rui; Zeng, Jing; Liu, Xiaoxia; Zhang, Dawei; Wu, Yongjie; Luo, Guangda; Zhang, Xu
2017-01-01
To evaluate the clinical usefulness of neutrophil-lymphocyte ratio (NLR) in differentiating the ultrasound-indeterminate renal multilocular cystic masses (RMCM) in comparison with computed tomography (CT) and whether NLR has additional benefits to CT on sensitivity of detecting the malignant. Overall, 93 patients who underwent normal ultrasound with a conclusion of indeterminate RMCM were examined by NLR and CT within 30 days before surgery or follow-up from March to September 2014 at PLA General Hospital and enrolled in this retrospective study. Logistic regression model was performed to find independent predictors for differentiating true nature of RMCM; differences in the validity parameters and diagnostic power of CT, NLR, and their combination were compared using McNemar tests and AUC model, respectively. The final diagnoses of the 93 patients consisted of 36 patients with benign complex cysts, 16 with multilocular cystic renal cell carcinoma, 9 with multilocular cystic nephroma, and 32 with clear cell renal cell carcinoma. Higher NLR were strongly associated with malignant masses. Multivariate logistic regression analysis revealed that NLR could be an independent predictor for differentiating true nature of these masses (OR = 3.617; 95% CI: 1.219-10.727; P = 0.020). For detecting the malignant masses, the sensitivity, specificity, and accuracy were 71.9%, 80.6%, and 75.3% for CT and 57.9%, 88.9%, and 69.9% for NLR under cutoff value of 2.31, respectively, whereas those of CT+NLR were 89.5%, 69.4%, and 81.7%. No significant difference was found between CT and NLR in sensitivity (P = 0.185), specificity (P = 0.549), and accuracy (P = 0.428). But the sensitivity of CT+NLR was significantly higher than those of CT (P = 0.002) and NLR (P<0.001), respectively; AUC model analysis indicated that CT+NLR got the largest area of 0.795 (P<0.001, 95% CI: 0.693-0.896) in comparison with those of CT (area = 0.795, P<0.001, 95% CI: 0.661-0.864) and NLR (area = 0.734, P<0.001, 95% CI: 0.631-0.836). Given that NLR, under cutoff value of 2.31, had no diagnostic difference with CT in evaluating the ultrasound-indeterminate RMCM. However, combination of CT and NLR could increase the sensitivity of detecting malignant masses and acquire the best diagnostic power. Prospectively larger cohort and multicenter studies are still necessary. Copyright © 2017 Elsevier Inc. All rights reserved.
Ectopic Multinodular Goiter: Multidetector Computed Tomography Findings
Karakaya, Afak Durur; Kantarci, Mecit; Yalcin, Ahmet; Demir, Berrin
2008-01-01
The thyroid is the first endocrine gland to form during embryogenesis. At this stage, incomplete or anomalous migration of thyroid tissue causes ectopic localization of the gland. In our case, a 55-year-old woman who was evaluated via ultrasonography (USG) and multi-detector computed tomography (MDCT) had no thyroid gland at the normal location, but did have ectopic thyroid tissue in the left submandibular and submental regions. PMID:25610021
SU-E-J-267: Change in Mean CT Intensity of Lung Tumors During Radiation Treatment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mahon, R; Tennyson, N; Weiss, E
2015-06-15
Purpose: To evaluate CT intensity change of lung tumors during radiation therapy. Methods: Repeated 4D CT images were acquired on a CT simulator during the course of therapy for 27 lung cancer patients on IRB approved protocols. All subjects received definitive radiation treatment ± chemotherapy. CT scans were completed prior to treatment, and 2–7 times during the treatment course. Primary tumor was delineated by an experienced Radiation Oncologist. Contours were thresholded between −100 HU and 200 HU to remove airways and bone. Correlations between the change in the mean tumor intensity and initial tumor intensity, SUVmax, and tumor volume changemore » rate were investigated. Reproducibility was assessed by evaluating the variation in mean intensity over all phases in 4DCT, for a subgroup of 19 subjects. Results: Reproducibility of tumor intensity between phases as characterized by the root mean square of standard deviation across 19 subjects was 1.8 HU. Subjects had a mean initial tumor intensity of 16.5 ± 11.6 HU and an overall reduction in HU by 10.3 ± 8.5 HU. Evaluation of the changes in tumor intensity during treatment showed a decrease of 0.3 ± 0.3 HU/day for all subjects, except three. No significant correlation was found between change in HU/day and initial HU intensity (p=0.53), initial PET SUVmax (p=0.69), or initial tumor volume (p=0.70). The rate of tumor volume change was weakly correlated (R{sup 2}=0.05) with HU change (p=0.01). Conclusion: Most lung cancer subjects showed a marked trend of decreasing mean tumor CT intensity throughout radiotherapy, including early in the treatment course. Change in HU/day is not correlated with other potential early predictors for response, such as SUV and tumor volume change. This Result supports future studies to evaluate change in tumor intensity on CT as an early predictor of response.« less
ALK molecular phenotype in non-small cell lung cancer: CT radiogenomic characterization.
Yamamoto, Shota; Korn, Ronald L; Oklu, Rahmi; Migdal, Christopher; Gotway, Michael B; Weiss, Glen J; Iafrate, A John; Kim, Dong-Wan; Kuo, Michael D
2014-08-01
To present a radiogenomic computed tomographic (CT) characterization of anaplastic lymphoma kinase (ALK)-rearranged non-small cell lung cancer (NSCLC) (ALK+). In this HIPAA-compliant institutional review board-approved retrospective study, CT studies, ALK status, and clinical-pathologic data in 172 patients with NSCLC from three institutions were analyzed. A screen of 24 CT image traits was performed in a training set of 59 patients, followed by random forest variable selection incorporating 24 CT traits plus six clinical-pathologic covariates to identify a radiogenomic predictor of ALK+ status. This predictor was then validated in an independent cohort (n = 113). Test-for-accuracy and subset analyses were performed. A similar analysis was performed to identify a biomarker associated with shorter progression-free survival (PFS) after therapy with the ALK inhibitor crizotinib. ALK+ status was associated with central tumor location, absence of pleural tail, and large pleural effusion. An ALK+ radiogenomic CT status biomarker consisting of these three imaging traits with patient age of younger than 60 years showed strong discriminatory power for ALK+ status, with a sensitivity of 83.3% (15 of 18), a specificity of 77.9% (74 of 95), and an accuracy of 78.8% (89 of 113) in independent testing. The discriminatory power was particularly strong in patients with operable disease (stage IIIA or lower), with a sensitivity of 100.0% (five of five), a specificity of 88.1% (37 of 42), and an accuracy of 89.4% (42 of 47). Tumors with a disorganized vessel pattern had a shorter PFS with crizotinib therapy than tumors without this trait (11.4 vs 20.2 months, P = .041). ALK+ NSCLC has distinct characteristics at CT imaging that, when combined with clinical covariates, discriminate ALK+ from non-ALK tumors and can potentially identify patients with a shorter durable response to crizotinib.
Zhan, Kevin Y; Morgan, Patrick F; Neskey, David M; Kim, Joanne J; Huang, Andrew T; Garrett-Mayer, Elizabeth; Day, Terry A
2018-05-14
Nodal disease predicts survival in oral cavity squamous cell carcinoma (SCC). Currently, no large studies on predictors of occult nodal disease in cT1N0 oral cavity SCC exist. The National Cancer Database (NCDB) review for cT1N0 oral cavity SCC with surgical resection and elective neck dissection (END). The number of patients found with occult nodal disease was 2623 (15.1%). In multivariable regression, female sex and tumor differentiation predict occult nodal disease. Occult nodal disease incidence was 5.9% in well-differentiated tumors, 17.4% in moderately differentiated tumors, and 28.5% in poorly differentiated tumor (P < .001). Women with oral tongue tumors had higher occult nodal disease (19.1%) than men (12%; P = .001). Adjusted odds ratios (aORs) for occult nodal disease in women were: aOR 1.26; 95% confidence interval (CI) 1.01-1.59; P = .045; moderately differentiated aOR 3.52; 95% CI 2.47-5.01; P < .001; and poorly differentiated aOR 6.25; 95% CI 4.17-9.38; P < .001. Sex and tumor differentiation significantly predict occult nodal disease. END is recommended for all moderately and poorly differentiated cT1N0 oral cavity SCC, regardless of the depth of invasion. One can consider not performing END in well-differentiated tumors. © 2018 Wiley Periodicals, Inc.
Jung, Yoon Suk; Park, Dong Il; Hong, Sung Noh; Kim, Eun Ran; Kim, Young Ho; Cheon, Jae Hee; Eun, Chang Soo; Han, Dong Soo; Lee, Chang Kyun; Kim, Jae Hak; Huh, Kyu Chan; Yoon, Soon Man; Song, Hyun Joo; Shin, Jeong Eun; Jeon, Seong Ran
2015-04-01
Patients with Crohn's disease (CD) are frequently exposed to diagnostic radiation, mainly as a result of abdominopelvic computed tomography (APCT) examinations. However, there are limited data on the impact of APCT on clinical management in this population. To investigate clinical predictors of urgent findings on APCT in patients with CD who presented to the emergency department (ED). A retrospective study was performed among patients with CD presenting to 11 EDs with a gastrointestinal complaint. The primary outcome, OPAN (obstruction, perforation, abscess, or non-CD-related urgent findings), included new or worsening CD-related urgent findings or non-CD-related urgent findings that required urgent or emergency treatment. Variables with P < 0.1 in univariate analyses were included in a multivariable logistic regression model. Of the 266 APCTs performed, 103 (38.7 %) had OPAN and 113 (42.5 %) required changes in treatment plan. Stricturing or penetrating disease (odds ratio [OR] 2.72, 95 % confidence interval [CI] 1.21-6.13), heart rate >100 beats/min (OR 2.33, 95 % CI 1.10-4.93), leukocyte count >10,000/mm(3) (OR 4.38, 95 % CI 2.10-9.13), and CRP >2.5 mg/dL (OR 3.11, 95 % CI 1.23-7.86) were identified as the independent predictors of OPAN, whereas biologic agent use (OR 0.37; 95 % CI 0.15-0.90) was identified as the negative predictor in patients with CD. Only 39 % of the APCTs performed in the ED among patients with CD showed urgent findings. Stricturing or penetrating disease, tachycardia, leukocytosis, and high CRP level were predictors of urgent CT findings, while biologic agent use was a negative predictor. To reduce unnecessary radiation exposure, the selection process for CD patients referred for APCT must be improved.
Phylogenetic ctDNA analysis depicts early stage lung cancer evolution
Abbosh, Christopher; Birkbak, Nicolai J.; Wilson, Gareth A.; Jamal-Hanjani, Mariam; Constantin, Tudor; Salari, Raheleh; Le Quesne, John; Moore, David A; Veeriah, Selvaraju; Rosenthal, Rachel; Marafioti, Teresa; Kirkizlar, Eser; Watkins, Thomas B K; McGranahan, Nicholas; Ward, Sophia; Martinson, Luke; Riley, Joan; Fraioli, Francesco; Al Bakir, Maise; Grönroos, Eva; Zambrana, Francisco; Endozo, Raymondo; Bi, Wenya Linda; Fennessy, Fiona M.; Sponer, Nicole; Johnson, Diana; Laycock, Joanne; Shafi, Seema; Czyzewska-Khan, Justyna; Rowan, Andrew; Chambers, Tim; Matthews, Nik; Turajlic, Samra; Hiley, Crispin; Lee, Siow Ming; Forster, Martin D.; Ahmad, Tanya; Falzon, Mary; Borg, Elaine; Lawrence, David; Hayward, Martin; Kolvekar, Shyam; Panagiotopoulos, Nikolaos; Janes, Sam M; Thakrar, Ricky; Ahmed, Asia; Blackhall, Fiona; Summers, Yvonne; Hafez, Dina; Naik, Ashwini; Ganguly, Apratim; Kareht, Stephanie; Shah, Rajesh; Joseph, Leena; Quinn, Anne Marie; Crosbie, Phil; Naidu, Babu; Middleton, Gary; Langman, Gerald; Trotter, Simon; Nicolson, Marianne; Remmen, Hardy; Kerr, Keith; Chetty, Mahendran; Gomersall, Lesley; Fennell, Dean; Nakas, Apostolos; Rathinam, Sridhar; Anand, Girija; Khan, Sajid; Russell, Peter; Ezhil, Veni; Ismail, Babikir; Irvin-sellers, Melanie; Prakash, Vineet; Lester, Jason; Kornaszewska, Malgorzata; Attanoos, Richard; Adams, Haydn; Davies, Helen; Oukrif, Dahmane; Akarca, Ayse U; Hartley, John A; Lowe, Helen L; Lock, Sara; Iles, Natasha; Bell, Harriet; Ngai, Yenting; Elgar, Greg; Szallasi, Zoltan; Schwarz, Roland F; Herrero, Javier; Stewart, Aengus; Quezada, Sergio A; Peggs, Karl S.; Van Loo, Peter; Dive, Caroline; Lin, Jimmy; Rabinowitz, Matthew; Aerts, Hugo JWL; Hackshaw, Allan; Shaw, Jacqui A; Zimmermann, Bernhard G.; Swanton, Charles
2017-01-01
Summary The early detection of relapse following primary surgery for non-small cell lung cancer and the characterization of emerging subclones seeding metastatic sites might offer new therapeutic approaches to limit tumor recurrence. The potential to non-invasively track tumor evolutionary dynamics in ctDNA of early-stage lung cancer is not established. Here we conduct a tumour-specific phylogenetic approach to ctDNA profiling in the first 100 TRACERx (TRAcking non-small cell lung Cancer Evolution through therapy (Rx)) study participants, including one patient co-recruited to the PEACE (Posthumous Evaluation of Advanced Cancer Environment) post-mortem study. We identify independent predictors of ctDNA release and perform tumor volume limit of detection analyses. Through blinded profiling of post-operative plasma, we observe evidence of adjuvant chemotherapy resistance and identify patients destined to experience recurrence of their lung cancer. Finally, we show that phylogenetic ctDNA profiling tracks the subclonal nature of lung cancer relapse and metastases, providing a new approach for ctDNA driven therapeutic studies PMID:28445469
Luo, Mingyue; Duan, Chaijie; Qiu, Jianping; Li, Wenru; Zhu, Dongyun; Cai, Wenli
2015-01-01
Purpose To evaluate the diagnostic value of multidetector CT (MDCT) and its multiplanar reformation (MPR), volume rendering (VR) and virtual bronchoscopy (VB) postprocessing techniques for primary trachea and main bronchus tumors. Methods Detection results of 31 primary trachea and main bronchus tumors with MDCT and its MPR, VR and VB postprocessing techniques, were analyzed retrospectively with regard to tumor locations, tumor morphologies, extramural invasions of tumors, longitudinal involvements of tumors, morphologies and extents of luminal stenoses, distances between main bronchus tumors and trachea carinae, and internal features of tumors. The detection results were compared with that of surgery and pathology. Results Detection results with MDCT and its MPR, VR and VB were consistent with that of surgery and pathology, included tumor locations (tracheae, n = 19; right main bronchi, n = 6; left main bronchi, n = 6), tumor morphologies (endoluminal nodes with narrow bases, n = 2; endoluminal nodes with wide bases, n = 13; both intraluminal and extraluminal masses, n = 16), extramural invasions of tumors (brokethrough only serous membrane, n = 1; 4.0 mm—56.0 mm, n = 14; no clear border with right atelectasis, n = 1), longitudinal involvements of tumors (3.0 mm, n = 1; 5.0 mm—68.0 mm, n = 29; whole right main bronchus wall and trachea carina, n = 1), morphologies of luminal stenoses (irregular, n = 26; circular, n = 3; eccentric, n = 1; conical, n = 1) and extents (mild, n = 5; moderate, n = 7; severe, n = 19), distances between main bronchus tumors and trachea carinae (16.0 mm, n = 1; invaded trachea carina, n = 1; >20.0 mm, n = 10), and internal features of tumors (fairly homogeneous densities with rather obvious enhancements, n = 26; homogeneous density with obvious enhancement, n = 1; homogeneous density without obvious enhancement, n = 1; not enough homogeneous density with obvious enhancement, n = 1; punctate calcification with obvious enhancement, n = 1; low density without obvious enhancement, n = 1). Conclusion MDCT and its MPR, VR and VB images have respective advantages and disadvantages. Their combination could complement to each other to accurately detect locations, natures (benignancy, malignancy or low malignancy), and quantities (extramural invasions, longitudinal involvements, extents of luminal stenoses, distances between main bronchus tumors and trachea carinae) of primary trachea and main bronchus tumors with crucial information for surgical treatment, are highly useful diagnostic methods for primary trachea and main bronchus tumors. PMID:26332466
Preoperative assessment of microvascular invasion in hepatocellular carcinoma
NASA Astrophysics Data System (ADS)
Chakraborty, Jayasree; Zheng, Jian; Gönen, Mithat; Jarnagin, William R.; DeMatteo, Ronald P.; Do, Richard K. G.; Simpson, Amber L.
2017-03-01
Hepatocellular carcinoma (HCC) is the most common liver cancer and the third leading cause of cancer-related death worldwide.1 Resection or liver transplantation may be curative in patients with early-stage HCC but early recurrence is common.2, 3 Microvascular invasion (MVI) is one of the most important predictors of early recurrence.3 The identification of MVI prior to surgery would optimally select patients for potentially curative resection or liver transplant. However, MVI can only be diagnosed by microscopic assessment of the resected tumor. The aim of the present study is to apply CT-based texture analysis to identify pre-operative imaging predictors of MVI in patients with HCC. Texture features are derived from CT and analyzed individually as well as in combination, to evaluate their ability to predict MVI. A two-stage classification is employed: HCC tumors are automatically categorized into uniform or heterogenous groups followed by classification into the presence or absence of MVI. We achieve an area under the receiver operating characteristic curve (AUC) of 0.76 and accuracy of 76.7% for uniform lesions and AUC of 0.79 and accuracy of 74.06% for heterogeneous tumors. These results suggest that MVI can be accurately and objectively predicted from preoperative CT scans.
The Impact of Critical Thinking on Clinical Judgment During Simulation With Senior Nursing Students.
Cazzell, Mary; Anderson, Mindi
2016-01-01
The study examined the impact of critical thinking (CT) on clinical judgment (CJ) during a pediatric Objective Structured Clinical Evaluation (OSCE) with 160 pre-licensure nursing students. Educators are called to transform teaching strategies to develop CJ but confusion exists over definitions. A descriptive correlational design was used to examine demographics and Tower of Hanoi (TOH) and Health Science Reasoning Test (HSRT) scores. CJ was measured by scores on the Lasater Clinical Judgment Rubric (LCJR) from videotaped OSCEs. Participants were: 86 percent female, 42 percent Caucasian, median 23 years, with 49 percent having health care experience. Students averaged seven moves over minimum on the TOH. Average scores were: HSRT 25/38 and LCJR 31/44. Statistically significant predictors of CJ were gender, ethnicity, HSRT deduction, and analysis; 11 CT variables accounted for 17 percent of LCJR scores. Educators need to utilize/develop innovative teaching strategies addressing CJ predictors.
Liver transplantation for fulminant hepatitis at Stanford University.
Lu, Amy; Monge, Humberto; Drazan, Kenneth; Millan, Maria; Esquivel, Carlos O
2002-01-01
To review the clinical characteristics and outcomes of 26 patients evaluated for liver transplantation for fulminant hepatic failure at Stanford University and Lucile Packard Children's Hospital in an attempt to identify risk factors and prognostic predictors of survival. A retrospective review of the records of 26 consecutive patients who were evaluated for possible liver transplantation for acute liver failure from May 1, 1995, to January 1, 2000. Pretransplant patient demographics and clinical characteristics were collected, and the data were analyzed by univariate and multivariate analysis. Clinical assessment of encephalopathy did not predict outcome. Patients with abnormal computed tomography (CT) of the brain had a twofold increase in mortality compared with those patients with normal studies (p = 0.03). Patients requiring mechanical ventilation and continuous venovenous hemofiltration (CVVH) also had a poor prognosis. Predictors of poor outcome after fulminant hepatic failure include abnormal CT scan, mechanical ventilation, and requirement for hemofiltration.
Shamim, Syed Ejaz; Nang, Lee Boon; Shuaib, Ibrahim Lutfi; Muhamad, Nor Asiah
2014-05-01
A cross-sectional prospective study has been conducted on differentiated thyroid cancer (DTC) patients using negative (131)Iodine ((131)I) whole body scans and elevated thyroglobulin (Tg) levels. The main objective of this research was to determine the prevalence of the conversion of differentiated to dedifferentiated thyroid cancer patients during follow up at the Hospital Kuala Lumpur. It has been demonstrated that fluorodeoxyglucose (FDG) uptake is inversely proportional to the iodine concentration and to differentiation of the cells. Thirty-five patients with histologically proven DTC that have undergone total or near total thyroidectomy, and post (131)I radioactive iodine ablation therapy, were selected and prospectively analysed. The patients also had to show at least one negative whole body scan and Tg levels of 10 μg/L and above. The results of the FDG-Positron Emission Tomography/Computed Tomography (PET/CT) were then studied to determine the association and the predictors influencing the outcome by using univariable and multivariable analyses. Out of the thirty-five patients, 60% of them (twenty-one) showed positive results and 40% (fourteen) showed negative. Age, gender, and type of histopathology (HPE) showed significant associations with the positive results of the FDG-PET/CT. The results also showed no correlations observed between the Tg levels and standardised uptake value (SUV)max in the DTC patients with positive disease findings in the FDG-PET/CT. The predictor for this study was age. The prevalence of the conversion of differentiated to dedifferentiated thyroid cancer among patients with negative (131)I and elevated Tg was 60%, with age as the predictor. DTC patients aged 45 year-old and older were seven times more likely to have positive results of FDG-PET/CT imaging.
SHAMIM, Syed Ejaz; NANG, Lee Boon; SHUAIB, Ibrahim Lutfi; MUHAMAD, Nor Asiah
2014-01-01
Background: A cross-sectional prospective study has been conducted on differentiated thyroid cancer (DTC) patients using negative 131Iodine (131I) whole body scans and elevated thyroglobulin (Tg) levels. The main objective of this research was to determine the prevalence of the conversion of differentiated to dedifferentiated thyroid cancer patients during follow up at the Hospital Kuala Lumpur. It has been demonstrated that fluorodeoxyglucose (FDG) uptake is inversely proportional to the iodine concentration and to differentiation of the cells. Methods: Thirty-five patients with histologically proven DTC that have undergone total or near total thyroidectomy, and post 131I radioactive iodine ablation therapy, were selected and prospectively analysed. The patients also had to show at least one negative whole body scan and Tg levels of 10 μg/L and above. The results of the FDG-Positron Emission Tomography/Computed Tomography (PET/CT) were then studied to determine the association and the predictors influencing the outcome by using univariable and multivariable analyses. Results: Out of the thirty-five patients, 60% of them (twenty-one) showed positive results and 40% (fourteen) showed negative. Age, gender, and type of histopathology (HPE) showed significant associations with the positive results of the FDG-PET/CT. The results also showed no correlations observed between the Tg levels and standardised uptake value (SUV)max in the DTC patients with positive disease findings in the FDG-PET/CT. The predictor for this study was age. Conclusion: The prevalence of the conversion of differentiated to dedifferentiated thyroid cancer among patients with negative 131I and elevated Tg was 60%, with age as the predictor. DTC patients aged 45 year-old and older were seven times more likely to have positive results of FDG-PET/CT imaging. PMID:25246834
Development of a Radiation Dose Reporting Software for X-ray Computed Tomography (CT)
NASA Astrophysics Data System (ADS)
Ding, Aiping
X-ray computed tomography (CT) has experienced tremendous technological advances in recent years and has established itself as one of the most popular diagnostic imaging tools. While CT imaging clearly plays an invaluable role in modern medicine, its rapid adoption has resulted in a dramatic increase in the average medical radiation exposure to the worldwide and United States populations. Existing software tools for CT dose estimation and reporting are mostly based on patient phantoms that contain overly simplified anatomies insufficient in meeting the current and future needs. This dissertation describes the development of an easy-to-use software platform, “VirtualDose”, as a service to estimate and report the organ dose and effective dose values for patients undergoing the CT examinations. “VirtualDose” incorporates advanced models for the adult male and female, pregnant women, and children. To cover a large portion of the ignored obese patients that frequents the radiology clinics, a new set of obese male and female phantoms are also developed and applied to study the effects of the fat tissues on the CT radiation dose. Multi-detector CT scanners (MDCT) and clinical protocols, as well as the most recent effective dose algorithms from the International Commission on Radiological Protection (ICRP) Publication 103 are adopted in “VirtualDose” to keep pace with the MDCT development and regulatory requirements. A new MDCT scanner model with both body and head bowtie filter is developed to cover both the head and body scanning modes. This model was validated through the clinical measurements. A comprehensive slice-by-slice database is established by deriving the data from a larger number of single axial scans simulated on the patient phantoms using different CT bowtie filters, beam thicknesses, and different tube voltages in the Monte Carlo N-Particle Extended (MCNPX) code. When compared to the existing CT dose software packages, organ dose data in this software provides a better CT dose assessment by using anatomically realistic patient phantoms. All the related organ doses are incorporated into a standardized database compiled using Microsoft Structured Query Language (SQL) server 2008. Organ doses from contiguous axial or helical scans defined by a specific protocol can be rapidly obtained from the database. A next-generation software architecture and Active Server Pages (ASP) .NET framework are adopted to create a browser-hosted application to improve the user interactivity and reporting functionality including scanning parameter selection and organ dose reporting. “VirtualDose” has been developed as a web-based CT dose reporting platform to facilitate several important features including: (1) easy access via Internet; (2) no need for installation on the local computer; (3) a user-friendly, dynamic, browser-hosted graphical user interface; (4) use of advanced patient models for the adult male and female, pregnant women, children, and obese patient models; (5) adoption of modern CT scanners and protocols, as well as the most recent ICRP 103 effective dose algorithms; and (6) flexibility to manage and easily upgrade without impacting user’s usage.
Rohan, Vladimir; Baxa, Jan; Tupy, Radek; Cerna, Lenka; Sevcik, Petr; Friesl, Michal; Polivka, Jiri; Polivka, Jiri; Ferda, Jiri
2014-07-01
The length of large vessel occlusion is considered a major factor for therapy in patients with ischemic stroke. We used 4D-CT angiography evaluation of middle cerebral artery occlusion in prediction of recanalization and favorable clinical outcome and after intravenous thrombolysis (IV-tPA). In 80 patients treated with IV-tPA for acute complete middle cerebral artery/M1 occlusion determined using CT angiography and temporal maximum intensity projection, calculated from 4D-CT angiography, the length of middle cerebral artery proximal stump, occlusion in M1 or M1 and M2 segment were measured. Univariate and multivariate analyses were performed to define independent predictors of successful recanalization after 24 hours and favorable outcome after 3 months. The length of occlusion was measureable in all patients using temporal maximum intensity projection. Recanalization thrombolysis in myocardial infarction 2 to 3 was achieved in 37 individuals (46%). The extension to M2 segment as a category (odds ratio, 4.58; 95% confidence interval, 1.39-15.05; P=0.012) and the length of M1 segment occlusion (odds ratio, 0.82; 95% confidence interval, 0.73-0.92; P=0.0007) with an optimal cutoff value of 12 mm (sensitivity 0.67; specificity 0.71) were significant independent predictors of recanalization. Favorable outcome (modified Rankin scale 0-2) was achieved in 25 patients (31%), baseline National Institutes of Health Stroke Scale (odds ratio, 0.82; 95% confidence interval, 0.72-0.93; P=0.003) and the length of occlusion M1 in segment (odds ratio, 0.79; 95% confidence interval, 0.69-0.91; P=0.0008) with an optimal cutoff value of 11 mm (sensitivity 0.74; specificity 0.76) were significant independent predictors of favorable outcome. The length of middle cerebral artery occlusion is an independent predictor of successful IV-tPA treatment. © 2014 American Heart Association, Inc.
Lambe, N R; Navajas, E A; Fisher, A V; Simm, G; Roehe, R; Bünger, L
2009-11-01
This study investigated how accurately taste panel sensory assessments of meat eating quality (MEQ) could be predicted in two divergent lamb breeds, using predictors measured in live animals (weights, subjective conformation assessments, ultrasound, computed tomography (CT) and video image analysis measurements) and carcasses (weights, MLC fat and conformation classes, pH, temperature, carcass dimensions and cross-sectional tissue dimensions), individually and in optimal combinations. Grilled muscle samples from the pelvic limb (semimembranosus) and loin (Longissimus lumborum) of 120 Texel (TEX) and 112 Scottish Blackface (SBF) lambs were assessed by a trained taste panel for texture, juiciness, flavour, abnormal flavour and overall liking. Residual correlations (adjusted for fixed effects, age and sire) between MEQ and predictor traits were low to moderate in size (<±0.42). MEQ traits predicted best by single measurements were loin flavour and overall liking for TEX (using fat area in a CT scan or subcutaneous fat depth measured post-mortem), and for SBF were leg texture (using carcass weight or temperature) and juiciness (using CT fat area or shoulder conformation score). Combining live animal and carcass measurements increased MEQ prediction accuracies, compared with using either set alone, to explain >40% of residual variation in several MEQ traits, with the highest adjusted R(2) values for leg juiciness in TEX (0.53) and leg texture in SBF (0.59). The most useful predictors of MEQ depended on breed, with measurements of fatness generally more important in the lean breed and carcass size and muscling more important in the fatter breed.
Automated contrast medium monitoring system for computed tomography--Intra-institutional audit.
Lauretti, Dario Luca; Neri, Emanuele; Faggioni, Lorenzo; Paolicchi, Fabio; Caramella, Davide; Bartolozzi, Carlo
2015-12-01
The aim of this study was to analyze the usage and the data recorded by a RIS-PACS-connected contrast medium (CM) monitoring system (Certegra(®), Bayer Healthcare, Leverkusen, Germany) over 19 months of CT activity. The system used was connected to two dual syringe power injectors (each associated with a 16-row and a high definition 64-row multidetector CT scanner, respectively), allowing to manage contrast medium injection parameters and to send and retrieve CT study-related information via RIS/PACS for any scheduled contrast-enhanced CT examination. The system can handle up to 64 variables and can be accessed via touchscreen by CT operators as well as via a web interface by registered users with three different hierarchy levels. Data related to CM injection parameters (i.e. iodine concentration, volume and flow rate of CM, iodine delivery rate and iodine dose, CM injection pressure, and volume and flow rate of saline), patient weight and height, and type of CT study over a testing period spanning from 1 June 2013 to 10 January 2015 were retrieved from the system. Technical alerts occurred for each injection event (such as system disarm due to technical failure, disarm due to operator's stop, incomplete filling of patient data fields, or excessively high injection pressure), as well as interoperability issues related to data sending and receiving to/from the RIS/PACS were also recorded. During the testing period, the CM monitoring system generated a total of 8609 reports, of which 7629 relative to successful injection events (88.6%). 331 alerts were generated, of which 40 resulted in injection interruption and 291 in CM flow rate limitation due to excessively high injection pressure (>325 psi). Average CM volume and flow rate were 93.73 ± 17.58 mL and 3.53 ± 0.89 mL/s, and contrast injection pressure ranged between 5 and 167 psi. A statistically significant correlation was found between iodine concentration and peak IDR (rs=0.2744, p<0.0001), as well as between iodine concentration and iodine dose (rs=0.3862, p<0.0001) for all CT studies. Automated contrast management systems can provide a full report of contrast use with the possibility to systematically compare different contrast injection protocols, minimize errors, and optimize organ-specific contrast enhancement for any given patient and clinical application. This can be useful to improve and harmonize the quality and consistency of contrast CT procedures within the same radiological department and across the hospital, as well as to monitor potential adverse events and overall costs. Copyright © 2015 Elsevier Ltd. All rights reserved.
Ohno, Takeshi; Araki, Fujio; Onizuka, Ryota; Hatemura, Masahiro; Shimonobou, Toshiaki; Sakamoto, Takashi; Okumura, Shuichiro; Ideguchi, Daichi; Honda, Keiichi; Kawata, Kenji
2017-03-01
This study compared dosimetric properties among four commercial multi-detector CT (MDCT) scanners. The X-ray beam characteristics were obtained from photon intensity attenuation curves of aluminum and off-center ratio (OCR) profiles in air, which were measured with four commercial MDCT scanners. The absorbed dose for MDCT scanners was evaluated with Farmer ionization chamber measurements at the center and four peripheral points in the body- and head-type cylindrical water phantoms. Measured collected charge was converted to absorbed dose using a 60 Co absorbed dose-to-water calibration factor and Monte Carlo (MC)-calculated correction factors. Four MDCT scanners were modeled to correspond with measured X-ray beam characteristics using GMctdospp (IMPS, Germany) software. Al half-value layers (Al-HVLs) with a body-bowtie filter determined from measured Al-attenuation curves ranged 7.2‒9.1mm at 120kVp and 6.1‒8.0mm at 100kVp. MC-calculated Al-HVLs and OCRs in air were in acceptable agreement within 0.5mm and 5% of measured values, respectively. The percentage difference between nominal and actual beam width was greater with decreasing collimation width. The absorbed doses for MDCT scanners at 120kVp ranged 5.1‒7.1mGy and 10.8‒17.5mGy per 100mAs at the center in the body- and head-type water phantoms, respectively. Measured doses at four peripheral points were within 5% agreement of MC-calculated values. The absorbed dose at the center in both water phantoms increased with decreasing Al-HVL for the same charge on the focus. In this study the X-ray beam characteristics and the absorbed dose were measured and compared with calculated values for four MDCT scanners. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Lee, Youn Joo; Lim, Yeon Soo; Lim, Hyun Wook; Yoo, Won Jong; Choi, Byung Gil; Kim, Bum Soo
2014-10-01
There are very few reports assessing in-stent restenosis (ISR) after vertebral artery ostium (VAO) stents using multidetector computed tomography (MDCT). To compare the diagnostic accuracy of computed tomography angiography (CTA) using 64-slice MDCT with digital subtraction angiography (DSA) for detection of significant ISR after VAO stenting. The study evaluated 57 VAO stents in 57 patients (39 men, 18 women; mean age 64 years [range, 48-90 years]). All stents were scanned with a 64-slice MDCT scanner. Three sets of images were reconstructed with three different convolution kernels. Two observers who were blinded to the results of DSA assessed the diagnostic accuracy of CTA for detecting significant ISR (≥50% diameter narrowing) of VAO stents in comparison with DSA as the reference standard. The sensitivity, specificity, positive and negative predictive values, and accuracy were calculated. Of the 57 stents, 46 (81%) were assessable using CTA, while 11 (19%) were not. No stents with diameters ≤2.75 mm were assessable. DSA revealed 13 cases of significant ISR in all stents. The respective sensitivity, specificity, positive and negative predictive values, and accuracy were 92%, 82%, 60%, 97%, and 84% for all stents. On excluding the 11 non-assessable stents, the respective values were 88%, 95%, 78%, 97%, and 93%. Of the 46 CTA assessable stents, eight significant ISRs were diagnosed on DSA. Seven of eight patients with significant ISR by DSA were diagnosed correctly with CTA. The area under the receiver-operating characteristic curve (AUC) was 0.87 for all stents and 0.91 for assessable stents, indicating good to excellent agreement between CTA and DSA for detecting significant ISR after VAO stenting. Sixty-four-slice MDCT is a promising non-invasive method of assessing stent patency and can exclude significant ISR with high diagnostic values after VAO stenting. © The Foundation Acta Radiologica 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Turba, Ulku Cenk; Uflacker, Renan; Bozlar, Ugur; Hagspiel, Klaus D
2009-03-01
The purpose of this study was to determine renal arterial anatomy and gender differences in adults without renovascular disease using multidetector computed tomography angiography (MDCTA). MDCTA datasets of 399 patients were retrospectively reviewed. Measurements of the aortorenal diameters, the angulation of the renal ostia and pedicles as well as the distance between the origins of the renal arteries were measured. Differences in measurements between genders were tested for statistical significance using analysis of variance (ANOVA) and Pearson's Chi-Square tests. A total of 798 renal arteries were available for analysis in 207 female (mean age = 52.91 years) and 192 male patients (mean age = 53.04 years). Female patients were found to have smaller aortae (at the level of the right renal ostium) and bilateral renal arteries than males (mean aortic diameter M/F = 18.33/15.89 mm, mean right renal artery ostial diameter M/F = 5.06/4.59 mm, mean left ostial renal diameter M/F = 5.14/4.66 mm) (p < .001). There was no statistical significance for the renal ostia level in relation to the vertebrae and the majority of renal arteries originated at the L1 and L2 levels. The longitudinal distance between right and left renal artery ostia ranged from 0 to 32 mm (mean = 4,6 mm, median = 5mm). The mean anteroposterior orientation of the right renal ostia was M/F = 29.45 degrees/28.20 degrees , and M/F = -7.96 degrees/-11.14 degrees for left renal artery ostia. The mean anteroposterior orientation of the right renal pedicle was M/F = 41.37 degrees/44.34 degrees and M/F = 42.31 degrees/43.95 degrees for the left pedicle. There are some differences in normal renal arterial anatomy between genders. Normal renal arterial information is useful not only for planning and performing of endovascular and laparoscopic urologic procedures, but also for medical device development. Copyright 2009 Wiley-Liss, Inc.
Ateşoğlu, Sibel; Deniz, Mustafa; Uslu, Ayşe İmge
2018-01-18
Sternum is one of the skeleton parts which have frequently congenital anomalies and variations are commonly used by researchers in determining sex. We evaluated the morphological characteristics and sex-related changes of the sternum in adult individuals using multidetector CT in our study. 200 adults (103 female and 97 male) aged between 18-87 years were evaluated. Utilizing the morphological characteristics of the sternum based on the multi-slice images; length, width and the thickness of Manubrium, length, width and the thickness of Corpus Sterni, total length of Sternum, Sternal angle, Sternal index, length of the xiphoid process, the thickness of xiphoid process, the number of indents of xiphoid process were measured and a total of 20 parameters were evaluated by adding age, height and weight to these variables. The mean length of the manubrium, the length of corpus sterni, the length of total sternum, sternal index, sternal angle were found in females 46.7±5.1,86.6±9.7, 133.1±1.1, 54.47±10.0 and 163.75±5.79; in males 51.2±6, 102.4±13.3, 154.1±13.1, 50.11±10.02 and 162.21±6.17, respectively. We found that Hyrtl's law and Sternal index did not provide adequate accuracy for sex determination in our patients. It has been detected that the length of the Manubrium alone is not helpful for individual samples. Total length of the sternum was found to be more reliable than the length of the Manubrium and the length of corpus Sterni. We determined Sternal cleft and Sternal foramen as 0.5% and 3.5%, respectively. We suggest that the Morphometric standards cannot be universally applied and can demonstrate individual differences. The standard rules must be implemented for every population.
Utsunomiya, Hiroto; Yamamoto, Hideya; Kunita, Eiji; Kitagawa, Toshiro; Ohashi, Norihiko; Oka, Toshiharu; Yamazato, Ryo; Horiguchi, Jun; Kihara, Yasuki
2010-11-01
We examined the association of aortic valve calcification (AVC) and mitral annular calcification (MAC) to coronary atherosclerosis using 64-multidetector computed tomography (MDCT). Valvular calcification is considered a manifestation of atherosclerosis. The impact of multiple heart valve calcium deposits on the distribution and characteristics of coronary plaque is unknown. We evaluated 322 patients referred for 64-MDCT, and assessed valvular calcification and the extent of calcified (CAP), mixed (MCAP), and noncalcified coronary atherosclerotic plaque (NCAP) in accordance with the 17-coronary segments model. We assessed the vulnerable characteristics of coronary plaque with positive remodeling, low-density plaque (CT density ≤38 Hounsfield units), and the presence of adjacent spotty calcification. In 49 patients with both AVC and MAC, the segment numbers of CAP and MCAP were larger than in those with a lack of valvular calcification and an isolated AVC (p<0.001 for both). Multivariate analyses revealed that a combined presence of AVC and MAC was independently associated with the presence (odds ratio [OR] 9.36, 95% confidence interval [95%CI] 1.55-56.53, p=0.015) and extent (β-estimate 1.86, p<0.001) of overall coronary plaque. When stratified by plaque composition, it was associated with the extent of CAP (β-estimate 1.77, p<0.001) and MCAP (β-estimate 1.04, p<0.001), but not with NCAP. Moreover, it was also related to the presence of coronary plaque with all three vulnerable characteristics (OR 4.87, 95%CI 1.85-12.83, p=0.001). The combined presence of AVC and MAC is highly associated with the presence, extent, and vulnerable characteristics of coronary plaque identified by 64-MDCT. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Ho, Lisa M; Nelson, Rendon C; Delong, David M
2007-05-01
To prospectively evaluate the use of lean body weight (LBW) as the main determinant of the volume and rate of contrast material administration during multi-detector row computed tomography of the liver. This HIPAA-compliant study had institutional review board approval. All patients gave written informed consent. Four protocols were compared. Standard protocol involved 125 mL of iopamidol injected at 4 mL/sec. Total body weight (TBW) protocol involved 0.7 g iodine per kilogram of TBW. Calculated LBW and measured LBW protocols involved 0.86 g of iodine per kilogram and 0.92 g of iodine per kilogram calculated or measured LBW for men and women, respectively. Injection rate used for the three experimental protocols was determined proportionally on the basis of the calculated volume of contrast material. Postcontrast attenuation measurements during portal venous phase were obtained in liver, portal vein, and aorta for each group and were summed for each patient. Patient-to-patient enhancement variability in same group was measured with Levene test. Two-tailed t test was used to compare the three experimental protocols with the standard protocol. Data analysis was performed in 101 patients (25 or 26 patients per group), including 56 men and 45 women (mean age, 53 years). Average summed attenuation values for standard, TBW, calculated LBW, and measured LBW protocols were 419 HU +/- 50 (standard deviation), 443 HU +/- 51, 433 HU +/- 50, and 426 HU +/- 33, respectively (P = not significant for all). Levene test results for summed attenuation data for standard, TBW, calculated LBW, and measured LBW protocols were 40 +/- 29, 38 +/- 33 (P = .83), 35 +/- 35 (P = .56), and 26 +/- 19 (P = .05), respectively. By excluding highly variable but poorly perfused adipose tissue from calculation of contrast medium dose, the measured LBW protocol may lessen patient-to-patient enhancement variability while maintaining satisfactory hepatic and vascular enhancement.
Prognostic value of (18)F-FDG PET/CT volumetric parameters in recurrent epithelial ovarian cancer.
Mayoral, M; Fernandez-Martinez, A; Vidal, L; Fuster, D; Aya, F; Pavia, J; Pons, F; Lomeña, F; Paredes, P
2016-01-01
Metabolic tumour volume (MTV) and total lesion glycolysis (TLG) from (18)F-FDG PET/CT are emerging prognostic biomarkers in various solid neoplasms. These volumetric parameters and the SUVmax have shown to be useful criteria for disease prognostication in preoperative and post-treatment epithelial ovarian cancer (EOC) patients. The purpose of this study was to evaluate the utility of (18)F-FDG PET/CT measurements to predict survival in patients with recurrent EOC. Twenty-six patients with EOC who underwent a total of 31 (18)F-FDG PET/CT studies for suspected recurrence were retrospectively included. SUVmax and volumetric parameters whole-body MTV (wbMTV) and whole-body TLG (wbTLG) with a threshold of 40% and 50% of the SUVmax were obtained. Correlation between PET parameters and progression-free survival (PFS) and the survival analysis of prognostic factors were calculated. Serous cancer was the most common histological subtype (76.9%). The median PFS was 12.5 months (range 10.7-20.6 months). Volumetric parameters showed moderate inverse correlation with PFS but there was no significant correlation in the case of SUVmax. The correlation was stronger for first recurrences. By Kaplan-Meier analysis and log-rank test, wbMTV 40%, wbMTV 50% and wbTLG 50% correlated with PFS. However, SUVmax and wbTLG 40% were not statistically significant predictors for PFS. Volumetric parameters wbMTV and wbTLG 50% measured by (18)F-FDG PET/CT appear to be useful prognostic predictors of outcome and may provide valuable information to individualize treatment strategies in patients with recurrent EOC. Copyright © 2015 Elsevier España, S.L.U. and SEMNIM. All rights reserved.
Transcranial Duplex Sonography Predicts Outcome following an Intracerebral Hemorrhage.
Camps-Renom, P; Méndez, J; Granell, E; Casoni, F; Prats-Sánchez, L; Martínez-Domeño, A; Guisado-Alonso, D; Martí-Fàbregas, J; Delgado-Mederos, R
2017-08-01
Several radiologic features such as hematoma volume are related to poor outcome following an intracerebral hemorrhage and can be measured with transcranial duplex sonography. We sought to determine the prognostic value of transcranial duplex sonography in patients with intracerebral hemorrhage. We conducted a prospective study of patients diagnosed with spontaneous intracerebral hemorrhage. Transcranial duplex sonography examinations were performed within 2 hours of baseline CT, and we recorded the following variables: hematoma volume, midline shift, third ventricle and lateral ventricle diameters, and the pulsatility index in both MCAs. We correlated these data with the CT scans and assessed the prognostic value of the transcranial duplex sonography measurements. We assessed early neurologic deterioration during hospitalization and mortality at 1-month follow-up. We included 35 patients with a mean age of 72.2 ± 12.8 years. Median baseline hematoma volume was 9.85 mL (interquartile range, 2.74-68.29 mL). We found good agreement and excellent correlation between transcranial duplex sonography and CT when measuring hematoma volume ( r = 0.791; P < .001) and midline shift ( r = 0.827; P < .001). The logistic regression analysis with transcranial duplex sonography measurements showed that hematoma volume was an independent predictor of early neurologic deterioration (OR, 1.078; 95% CI, 1.023-1.135) and mortality (OR, 1.089; 95% CI, 1.020-1.160). A second regression analysis with CT variables also demonstrated that hematoma volume was associated with early neurologic deterioration and mortality. When we compared the rating operation curves of both models, their predictive power was similar. Transcranial duplex sonography showed an excellent correlation with CT in assessing hematoma volume and midline shift in patients with intracerebral hemorrhage. Hematoma volume measured with transcranial duplex sonography was an independent predictor of poor outcome. © 2017 by American Journal of Neuroradiology.
Aamli Gagnat, Ane; Gjerdevik, Miriam; Gallefoss, Frode; Coxson, Harvey O; Gulsvik, Amund; Bakke, Per
2017-05-01
There is limited knowledge about the prognostic value of quantitative computed tomography (CT) measures of emphysema and airway wall thickness in cancer.The aim of this study was to investigate if using CT to quantitatively assess the amount of emphysema and airway wall thickness independently predicts the subsequent incidence of non-pulmonary cancer and lung cancer.In the GenKOLS study of 2003-2005, 947 ever-smokers performed spirometry and underwent CT examination. The main predictors were the amount of emphysema measured by the percentage of low attenuation areas (%LAA) on CT and standardised measures of airway wall thickness (AWT-PI10). Cancer data from 2003-2013 were obtained from the Norwegian Cancer Register. The hazard ratio associated with emphysema and airway wall thickness was assessed using Cox proportional hazards regression for cancer diagnoses.During 10 years of follow-up, non-pulmonary cancer was diagnosed in 11% of the subjects with LAA <3%, in 19% of subjects with LAA 3-10%, and in 17% of subjects with LAA ≥10%. Corresponding numbers for lung cancer were 2%, 3% and 11%, respectively. After adjustment, the baseline amount of emphysema remained a significant predictor of the incidence of non-pulmonary cancer and lung cancer. Airway wall thickness did not predict cancer independently.This study offers a strong argument that emphysema is an independent risk factor for both non-pulmonary cancer and lung cancer. Copyright ©ERS 2017.
Genetic factors contribute to bleeding after cardiac surgery.
Welsby, I J; Podgoreanu, M V; Phillips-Bute, B; Mathew, J P; Smith, P K; Newman, M F; Schwinn, D A; Stafford-Smith, M
2005-06-01
Postoperative bleeding remains a common, serious problem for cardiac surgery patients, with striking inter-patient variability poorly explained by clinical, procedural, and biological markers. We tested the hypothesis that genetic polymorphisms of coagulation proteins and platelet glycoproteins are associated with bleeding after cardiac surgery. Seven hundred and eighty patients undergoing aortocoronary surgery with cardiopulmonary bypass were studied. Clinical covariates previously associated with bleeding were recorded and DNA isolated from preoperative blood. Matrix Assisted Laser Desorption/Ionization, Time-Of-Flight (MALDI-TOF) mass spectroscopy or polymerase chain reaction were used for genotype analysis. Multivariable linear regression modeling, including all genetic main effects and two-way gene-gene interactions, related clinical and genetic predictors to bleeding from the thorax and mediastinum. Nineteen candidate polymorphisms were assessed; seven [GPIaIIa-52C>T and 807C>T, GPIb alpha 524C>T, tissue factor-603A>G, prothrombin 20210G>A, tissue factor pathway inhibitor-399C>T, and angiotensin converting enzyme (ACE) deletion/insertion] demonstrate significant association with bleeding (P < 0.01). Adding genetic to clinical predictors results improves the model, doubling overall ability to predict bleeding (P < 0.01). We identified seven genetic polymorphisms associated with bleeding after cardiac surgery. Genetic factors appear primarily independent of, and explain at least as much variation in bleeding as clinical covariates; combining genetic and clinical factors double our ability to predict bleeding after cardiac surgery. Accounting for genotype may be necessary when stratifying risk of bleeding after cardiac surgery.
Variations of right bronchial tree: a study with multi-detector CT.
Wang, Tao; Meng, Min; Huang, Min; Zhao, Xinya
2018-05-03
The aim was to display variations of right bronchial tree. The bronchial tree images of 238 patients were reconstructed using the postprocessing technique of CT. We revealed four cases rare bronchial branching patterns of right superior lobe. 1 case was referred to as tracheal bronchus. In 1 case, B1 was located in the place of the right superior lobar bronchus and B2 + 3 arose from the right merge of the IB. In 1 case, the right superior lobar bronchus has only two divisions for B1 and B3, and the bronchus B2 arose from the right merge of the IB. In 1 case, B1 branched into four bronchi. We revealed 15 cases of rare bronchial branching patterns of right inferior lobe. In nine cases, the basal trunk bronchus bifurcated into B7 + 8 and B9 + l0. In three cases, B8 branched from the basal trunk bronchus before B7. In two cases, basal trunk bronchus bifurcated into B7 + 8 + 9 and B10. In 1 case, the basal trunk bronchus bifurcated into the common stem of B7 + 10 and B8 + 9. Variations of right bronchial tree were displayed in the present study. This information may have important implications for diagnosis of symptomatic patients and performing certain procedures, including bronchoscopy, endotracheal intubation, and lung resection.
Ohno, Yoshiharu; Nishio, Mizuho; Koyama, Hisanobu; Yoshikawa, Takeshi; Matsumoto, Sumiaki; Seki, Shinichiro; Obara, Makoto; van Cauteren, Marc; Takahashi, Masaya; Sugimura, Kazuro
2014-04-01
To assess the influence of ultrashort TE (UTE) intervals on pulmonary magnetic resonance imaging (MRI) with UTEs (UTE-MRI) for pulmonary functional loss assessment and clinical stage classification of smokers. A total 60 consecutive smokers (43 men and 17 women; mean age 70 years) with and without COPD underwent thin-section multidetector row computed tomography (MDCT), UTE-MRI, and pulmonary functional measurements. For each smoker, UTE-MRI was performed with three different UTE intervals (UTE-MRI A: 0.5 msec, UTE-MRI B: 1.0 msec, UTE-MRI C: 1.5 msec). By using the GOLD guidelines, the subjects were classified as: "smokers without COPD," "mild COPD," "moderate COPD," and "severe or very severe COPD." Then the mean T2* value from each UTE-MRI and CT-based functional lung volume (FLV) were correlated with pulmonary function test. Finally, Fisher's PLSD test was used to evaluate differences in each index among the four clinical stages. Each index correlated significantly with pulmonary function test results (P < 0.05). CT-based FLV and mean T2* values obtained from UTE-MRI A and B showed significant differences among all groups except between "smokers without COPD" and "mild COPD" groups (P < 0.05). UTE-MRI has a potential for management of smokers and the UTE interval is suggested as an important parameter in this setting. Copyright © 2013 Wiley Periodicals, Inc.
Hypertrophic Cardiomyopathy from A to Z: Genetics, Pathophysiology, Imaging, and Management.
Baxi, Ameya Jagdish; Restrepo, Carlos S; Vargas, Daniel; Marmol-Velez, Alejandro; Ocazionez, Daniel; Murillo, Horacio
2016-01-01
Hypertrophic cardiomyopathy (HCM) is a heterogeneous group of diseases related to sarcomere gene mutations exhibiting heterogeneous phenotypes with an autosomal dominant mendelian pattern of inheritance. The disorder is characterized by diverse phenotypic expressions and variable natural progression, which may range from dyspnea and/or syncope to sudden cardiac death. It is found across all racial groups and is associated with left ventricular hypertrophy in the absence of another systemic or cardiac disease. The management of HCM is based on a thorough understanding of the underlying morphology, pathophysiology, and clinical course. Imaging findings of HCM mirror the variable expressivity and penetrance heterogeneity, with the added advantage of diagnosis even in cases where a specific mutation may not yet be found. The diagnostic information obtained from imaging varies depending on the specific stage of HCM-phenotype manifestation, including the prehypertrophic, hypertrophic, and later stages of adverse remodeling into the burned-out phase of overt heart failure. However, subtle or obvious, these imaging findings become critical components in diagnosis, management, and follow-up of HCM patients. Although diagnosis of HCM traditionally relies on clinical assessment and transthoracic echocardiography, recent studies have demonstrated increased utility of multidetector computed tomography (CT) and particularly cardiac magnetic resonance (MR) imaging in diagnosis, phenotype differentiation, therapeutic planning, and prognostication. In this article, we provide an overview of the genetics, pathophysiology, and clinical manifestations of HCM, with the spectrum of imaging findings at MR imaging and CT and their contribution in diagnosis, risk stratification, and therapy. (©)RSNA, 2016.
Anatomical thoracoscopic segmentectomy for lung cancer.
Ohtaki, Yoichi; Shimizu, Kimihiro
2014-10-01
Minimally invasive surgery for lung cancer has seen considerable progress. A segmentectomy is less invasive than a lobectomy as it preserves lung parenchyma. The preservation of pulmonary function can reduce complications. The combination of a thoracoscopic approach with a segmentectomy should be less invasive, and retrospective studies have shown that the thoracoscopic approach is safe and feasible due to the lower postoperative mortality and complication rates as compared to an open thoracotomy. The validity of a segmentectomy for ground-glass-opacity-type lung cancer has been demonstrated, and it has also been evaluated for small, predominantly solid, lung cancers. Two prospective studies of segmentectomy versus lobectomy for ≤2-cm non-small-cell lung cancer are now underway (CALGB 140503 and JCOG0802/WJTOG4607L) and should clarify the role of segmentectomy. Regarding thoracoscopic segmentectomy, few retrospective studies have reported the oncological outcome for lung cancer and there is inadequate evidence regarding the long-term oncological outcome, although the perioperative complication rate and duration of hospital stay seem to be non-inferior to those of an open approach. For preoperative simulation, three-dimensional multidetector computed tomography (3D-CT) is essential for performing an atypical thoracoscopic segmentectomy safely. Preoperative 3D-CT angiography and bronchography (3D-CTAB) enable accurate identification of the venous branches in the affected segment and the intersegmental vein. This review describes the surgical and oncological outcomes, utility of 3D-CTAB, and surgical techniques and procedure used for a thoracoscopic segmentectomy.
Blunt chest trauma--an audit of injuries diagnosed by the MDCT examination.
Turkalj, Ivan; Petrović, Kosta; Stojanović, Sanja; Petrović, Djordje; Brakus, Alma; Ristić, Jelena
2014-02-01
Multidetector computed tomography (MDCT) characterised by speed and precision is increasingly accessible in emergency wards. The aim of our study was to determine the most common injuries to the chest region, as well as type associated extrathoracic injuries, and the treatment outcome. This prospective study included 61 patients with blunt trauma who were submitted to computed tomography (CT) of the thorax. The number of injuries was evaluated by organs and organ systems of the chest. The cause of the injury, the length and the outcome of the treatment, and the presence of injuries in other regions were assessed. Chest injuries were associated with injuries to other regions in 80.3% cases, predominantly injuries to extremities or pelvic bones in 54.1% cases, followed by head injuries in 39.3% patients. Associated thoracic injuries were present in 90.9% of patients with lethal outcome. Lung parenchymal lesions, pleural effusions and rib fractures were the most common injuries affecting 77.1%, 65.6% and 63.9% of the cases, respectively. Blunt chest trauma is a significant problem affecting predominantly males in their forties and it is usually caused by a motor vehicle accident. In case of pneumomediastinum or mediastinal haematoma, the use of 3D reconstructions is advised for diagnosing possible tracheobronchial ruptures and thoracic aorta injuries. Increased resolution of CT scanners yielded a large number of findings that are occult on radiography, especially in the event of lung parenchymal and pleural injuries. However, none imaging modality can replace surgical judgement.
NASA Astrophysics Data System (ADS)
Checefsky, Walter A.; Abidin, Anas Z.; Nagarajan, Mahesh B.; Bauer, Jan S.; Baum, Thomas; Wismüller, Axel
2016-03-01
The current clinical standard for measuring Bone Mineral Density (BMD) is dual X-ray absorptiometry, however more recently BMD derived from volumetric quantitative computed tomography has been shown to demonstrate a high association with spinal fracture susceptibility. In this study, we propose a method of fracture risk assessment using structural properties of trabecular bone in spinal vertebrae. Experimental data was acquired via axial multi-detector CT (MDCT) from 12 spinal vertebrae specimens using a whole-body 256-row CT scanner with a dedicated calibration phantom. Common image processing methods were used to annotate the trabecular compartment in the vertebral slices creating a circular region of interest (ROI) that excluded cortical bone for each slice. The pixels inside the ROI were converted to values indicative of BMD. High dimensional geometrical features were derived using the scaling index method (SIM) at different radii and scaling factors (SF). The mean BMD values within the ROI were then extracted and used in conjunction with a support vector machine to predict the failure load of the specimens. Prediction performance was measured using the root-mean-square error (RMSE) metric and determined that SIM combined with mean BMD features (RMSE = 0.82 +/- 0.37) outperformed MDCT-measured mean BMD (RMSE = 1.11 +/- 0.33) (p < 10-4). These results demonstrate that biomechanical strength prediction in vertebrae can be significantly improved through the use of SIM-derived texture features from trabecular bone.
Schoenhagen, Paul; Zimmermann, Mathis; Falkner, Juergen
2013-06-01
Degenerative aortic stenosis is highly prevalent in the aging populations of industrialized countries and is associated with poor prognosis. Surgical valve replacement has been the only established treatment with documented improvement of long-term outcome. However, many of the older patients with aortic stenosis (AS) are high-risk or ineligible for surgery. For these patients, transcatheter aortic valve replacement (TAVR) has emerged as a treatment alternative. The TAVR procedure is characterized by a lack of visualization of the operative field. Therefore, pre- and intra-procedural imaging is critical for patient selection, pre-procedural planning, and intra-operative decision-making. Incremental to conventional angiography and 2-D echocardiography, multidetector computed tomography (CT) has assumed an important role before TAVR. The analysis of 3-D CT data requires extensive post-processing during direct interaction with the dataset, using advance analysis software. Organization and storage of the data according to complex clinical workflows and sharing of image information have become a critical part of these novel treatment approaches. Optimally, the data are integrated into a comprehensive image data file accessible to multiple groups of practitioners across the hospital. This creates new challenges for data management requiring a complex IT infrastructure, spanning across multiple locations, but is increasingly achieved with client-server solutions and private cloud technology. This article describes the challenges and opportunities created by the increased amount of patient-specific imaging data in the context of TAVR.
Utility of CT Findings in the Diagnosis of Cecal Volvulus.
Dane, Bari; Hindman, Nicole; Johnson, Evan; Rosenkrantz, Andrew B
2017-10-01
The objective of our study was to assess the utility of CT features in the diagnosis of cecal volvulus. Forty-three patients undergoing CT for cecal volvulus and with surgical or clinical follow-up were included. Two radiologists (11 years and 1 year of experience) evaluated CT examinations for the following: whirl sign, abnormal cecal position, "bird beak" sign, severe cecal distention, mesenteric engorgement, a newly described "central appendix" sign (defined as abnormal appendix position near midline), and overall impression for cecal volvulus. Univariable and multivariable assessments were performed. Patients with CT examinations in which the appendix was not visible were excluded from calculations involving the central appendix sign. Fifty-one percent (n = 22) of patients had cecal volvulus. All CT findings were significantly more common in patients with cecal volvulus (p < 0.01) other than mesenteric engorgement for reader 1 (p = 0.332). Readers 1 and 2 identified the central appendix sign in 92.9% and 92.3% of patients with volvulus versus in 37.5 and 31.1% of patients without volvulus. The whirl sign exhibited a sensitivity for cecal volvulus of 90.9% for reader 1 and 95.5% for reader 2, and a specificity of 61.9% for both readers. Abnormal cecal position exhibited a sensitivity of 90.0% for reader 1 and 100.0% for reader 2 and a specificity of 66.7% and 38.1%. The bird beak sign exhibited a sensitivity of 86.4% for reader 1 and 100.0% for reader 2 and a specificity of 85.7% and 71.4%. Severe cecal distention exhibited a sensitivity of 100.0% for both readers and a specificity of 81.0% and 61.9%. Mesenteric engorgement exhibited a sensitivity of 40.9% for reader 1 and 100.0% for reader 2 and a specificity of 76.2% and 71.4%. The central appendix sign exhibited a sensitivity of 92.9% for reader 1 and 92.3% for reader 2 and a specificity of 62.5% and 68.8%. Overall impression exhibited a sensitivity of 100.0% for both readers and a specificity of 76.2% and 57.1%. At multivariable analysis, the AUC for cecal volvulus ranged from 0.787 to 0.931, and the whirl sign was an independent predictor of volvulus for both readers (p ≤ 0.014); the central appendix sign was also an independent predictor in patients with a visualized appendix for reader 2 (p ≤ 0.001). CT exhibited high diagnostic performance and very high sensitivity for cecal volvulus. The whirl sign was a significant independent predictor of volvulus for both readers.
Bhure, U N; Lardinois, D; Kalff, V; Hany, T F; Soltermann, A; Seifert, B; Steinert, H C
2010-10-01
Accurate determination of tumour size in lung adenocarcinoma with bronchoalveolar features (BAC) is important for the determination of TNM (tumour, nodes, metastasis) scores used in staging, prognosis and therapy response assessment. However, tumour sizes derived using lung window (LW) CT or soft-tissue/mediastinal window (MW) CT often give different results. This study examines which measurement correlates best with actual tumour size and which best identifies advanced disease. This retrospective study included 43 BAC patients who underwent surgical resection with mediastinal lymphadenectomy <4 weeks post CT scan. The largest unidimensional tumour diameter on each CT window was compared with actual histopathological tumour size (HP). LW, MW and HP size measurements and a recently described CT parameter - the modified tumour shadow disappearance rate (mTDR) = (1 - [MW/LW]) - were then used to determine which parameter best discriminated between the presence or absence of advanced disease. There was no difference between HP and LW sizes, but MW significantly underestimated HP size (p<0.0001). Unlike MW (p = 0.01) and mTDR (p = 0.001), neither HP (p = 0.14) nor LW (p = 0.10) distinguished between patients with or without advanced disease. On receiver operating characteristic (ROC) analysis at a cut-off of ≤0.13, the sensitivity and specificity of mTDR for detecting advanced disease were 69% and 89%, respectively. In patients with tumours ≤3 cm, only mTDR remained a significant predictor of advanced disease (p = 0.017), with best cut-off at ≤0.20, giving a sensitivity and specificity of 71% and 94%, respectively. MW better predicts advanced disease than LW and might also need to be recorded for RECIST (response evaluation criteria in solid tumours) assessment for T staging of BAC; however, mTDR appears to be an even better predictor and should also be used.
Hanning, Uta; Sporns, Peter Bernhard; Lebiedz, Pia; Niederstadt, Thomas; Zoubi, Tarek; Schmidt, Rene; Knecht, Stefan; Heindel, Walter; Kemmling, André
2016-07-01
Early prediction of potential neurological recovery in patients after cardiac arrest is challenging. Recent studies suggest that the densitrometic gray-white matter ratio (GWR) determined from cranial computed tomography (CT) scans may be a reliable predictor of poor outcome. We evaluated an automated, rater independent method to determine GWR in CT as an early objective imaging predictor of clinical outcome. We analyzed imaging data of 84 patients after cardiac arrest that underwent noncontrast CT within 24h after arrest. To determine GWR in CT we applied two methods using a recently published automated probabilistic gray-white matter segmentation algorithm (GWR_aut) and conventional manual measurements within gray-white regions of interest (GWR_man). Neurological outcome was graded by the cerebral performance category (CPC). As part of standard routine CPC was assessed by the treating physician in the intensive care unit at admission and at discharge to normal ward. The performance of GWR measures (automated and manual) to predict the binary clinical endpoints of poor (CPC3-5) and good outcome (CPC1-2) was assessed by ROC analysis with increasing discrimination thresholds. Results of GWR_aut were compared to GWR_man of two raters. Of 84 patients, 55 (65%) showed a poor outcome. ROC curve analysis revealed reliable outcome prediction of GWR_aut (AUC 0.860) and GWR_man (AUC 0.707 and 0.699, respectively). Predictive power of GWR_aut was higher than GWR_man by each rater (p=0.019 and p=0.021, respectively) at an optimal cut-off of 1.084 to predict poor outcome (optimal criterion with 92.7% sensitivity, 72.4% specificity). Interrater reliability of GWR_man by intra-class correlation coefficient (ICC) was moderate (0.551). Automated quantification of GWR in CT may be used as an objective observer-independent imaging marker for outcome in patients after cardiac arrest. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Knaub, D.; Yerazunis, S. W.
1978-01-01
Vertical wheel loads, wheel speeds, and torque relationships are considered in the design of a propulsion system capable of responding to steering, slope climbing, and irregular local terrains. The system developed is applied to the RPI Mars roving vehicle. The mechanical system required to implement the elevation laser scanning/multidetector principle was the design and construction of a mechanical system for implementing the elevation scanning/multidetector principle is also discussed.
NASA Astrophysics Data System (ADS)
Leproux, Anaïs; Kim, You Me; Min, Jun Won; McLaren, Christine E.; Chen, Wen-Pin; O'Sullivan, Thomas D.; Lee, Seung-ha; Chung, Phil-Sang; Tromberg, Bruce J.
2016-07-01
Young patients with dense breasts have a relatively low-positive biopsy rate for breast cancer (˜1 in 7). South Korean women have higher breast density than Westerners. We investigated the benefit of using a functional and metabolic imaging technique, diffuse optical spectroscopic imaging (DOSI), to help the standard of care imaging tools to distinguish benign from malignant lesions in premenopausal Korean women. DOSI uses near-infrared light to measure breast tissue composition by quantifying tissue concentrations of water (ctH2O), bulk lipid (ctLipid), deoxygenated (ctHHb), and oxygenated (ctHbO2) hemoglobin. DOSI spectral signatures specific to abnormal tissue and absent in healthy tissue were also used to form a malignancy index. This study included 19 premenopausal subjects (average age 41±9), corresponding to 11 benign and 10 malignant lesions. Elevated lesion to normal ratio of ctH2O, ctHHb, ctHbO2, total hemoglobin (THb=ctHHb+ctHbO2), and tissue optical index (ctHHb×ctH2O/ctLipid) were observed in the malignant lesions compared to the benign lesions (p<0.02). THb and malignancy index were the two best single predictors of malignancy, with >90% sensitivity and specificity. Malignant lesions showed significantly higher metabolism and perfusion than benign lesions. DOSI spectral features showed high discriminatory power for distinguishing malignant and benign lesions in dense breasts of the Korean population.
Phylogenetic ctDNA analysis depicts early-stage lung cancer evolution.
Abbosh, Christopher; Birkbak, Nicolai J; Wilson, Gareth A; Jamal-Hanjani, Mariam; Constantin, Tudor; Salari, Raheleh; Le Quesne, John; Moore, David A; Veeriah, Selvaraju; Rosenthal, Rachel; Marafioti, Teresa; Kirkizlar, Eser; Watkins, Thomas B K; McGranahan, Nicholas; Ward, Sophia; Martinson, Luke; Riley, Joan; Fraioli, Francesco; Al Bakir, Maise; Grönroos, Eva; Zambrana, Francisco; Endozo, Raymondo; Bi, Wenya Linda; Fennessy, Fiona M; Sponer, Nicole; Johnson, Diana; Laycock, Joanne; Shafi, Seema; Czyzewska-Khan, Justyna; Rowan, Andrew; Chambers, Tim; Matthews, Nik; Turajlic, Samra; Hiley, Crispin; Lee, Siow Ming; Forster, Martin D; Ahmad, Tanya; Falzon, Mary; Borg, Elaine; Lawrence, David; Hayward, Martin; Kolvekar, Shyam; Panagiotopoulos, Nikolaos; Janes, Sam M; Thakrar, Ricky; Ahmed, Asia; Blackhall, Fiona; Summers, Yvonne; Hafez, Dina; Naik, Ashwini; Ganguly, Apratim; Kareht, Stephanie; Shah, Rajesh; Joseph, Leena; Marie Quinn, Anne; Crosbie, Phil A; Naidu, Babu; Middleton, Gary; Langman, Gerald; Trotter, Simon; Nicolson, Marianne; Remmen, Hardy; Kerr, Keith; Chetty, Mahendran; Gomersall, Lesley; Fennell, Dean A; Nakas, Apostolos; Rathinam, Sridhar; Anand, Girija; Khan, Sajid; Russell, Peter; Ezhil, Veni; Ismail, Babikir; Irvin-Sellers, Melanie; Prakash, Vineet; Lester, Jason F; Kornaszewska, Malgorzata; Attanoos, Richard; Adams, Haydn; Davies, Helen; Oukrif, Dahmane; Akarca, Ayse U; Hartley, John A; Lowe, Helen L; Lock, Sara; Iles, Natasha; Bell, Harriet; Ngai, Yenting; Elgar, Greg; Szallasi, Zoltan; Schwarz, Roland F; Herrero, Javier; Stewart, Aengus; Quezada, Sergio A; Peggs, Karl S; Van Loo, Peter; Dive, Caroline; Lin, C Jimmy; Rabinowitz, Matthew; Aerts, Hugo J W L; Hackshaw, Allan; Shaw, Jacqui A; Zimmermann, Bernhard G; Swanton, Charles
2017-04-26
The early detection of relapse following primary surgery for non-small-cell lung cancer and the characterization of emerging subclones, which seed metastatic sites, might offer new therapeutic approaches for limiting tumour recurrence. The ability to track the evolutionary dynamics of early-stage lung cancer non-invasively in circulating tumour DNA (ctDNA) has not yet been demonstrated. Here we use a tumour-specific phylogenetic approach to profile the ctDNA of the first 100 TRACERx (Tracking Non-Small-Cell Lung Cancer Evolution Through Therapy (Rx)) study participants, including one patient who was also recruited to the PEACE (Posthumous Evaluation of Advanced Cancer Environment) post-mortem study. We identify independent predictors of ctDNA release and analyse the tumour-volume detection limit. Through blinded profiling of postoperative plasma, we observe evidence of adjuvant chemotherapy resistance and identify patients who are very likely to experience recurrence of their lung cancer. Finally, we show that phylogenetic ctDNA profiling tracks the subclonal nature of lung cancer relapse and metastasis, providing a new approach for ctDNA-driven therapeutic studies.
Dose coefficients in pediatric and adult abdominopelvic CT based on 100 patient models.
Tian, Xiaoyu; Li, Xiang; Segars, W Paul; Frush, Donald P; Paulson, Erik K; Samei, Ehsan
2013-12-21
Recent studies have shown the feasibility of estimating patient dose from a CT exam using CTDI(vol)-normalized-organ dose (denoted as h), DLP-normalized-effective dose (denoted as k), and DLP-normalized-risk index (denoted as q). However, previous studies were limited to a small number of phantom models. The purpose of this work was to provide dose coefficients (h, k, and q) across a large number of computational models covering a broad range of patient anatomy, age, size percentile, and gender. The study consisted of 100 patient computer models (age range, 0 to 78 y.o.; weight range, 2-180 kg) including 42 pediatric models (age range, 0 to 16 y.o.; weight range, 2-80 kg) and 58 adult models (age range, 18 to 78 y.o.; weight range, 57-180 kg). Multi-detector array CT scanners from two commercial manufacturers (LightSpeed VCT, GE Healthcare; SOMATOM Definition Flash, Siemens Healthcare) were included. A previously-validated Monte Carlo program was used to simulate organ dose for each patient model and each scanner, from which h, k, and q were derived. The relationships between h, k, and q and patient characteristics (size, age, and gender) were ascertained. The differences in conversion coefficients across the scanners were further characterized. CTDI(vol)-normalized-organ dose (h) showed an exponential decrease with increasing patient size. For organs within the image coverage, the average differences of h across scanners were less than 15%. That value increased to 29% for organs on the periphery or outside the image coverage, and to 8% for distributed organs, respectively. The DLP-normalized-effective dose (k) decreased exponentially with increasing patient size. For a given gender, the DLP-normalized-risk index (q) showed an exponential decrease with both increasing patient size and patient age. The average differences in k and q across scanners were 8% and 10%, respectively. This study demonstrated that the knowledge of patient information and CTDIvol/DLP values may be used to estimate organ dose, effective dose, and risk index in abdominopelvic CT based on the coefficients derived from a large population of pediatric and adult patients.
Performance evaluation of a 64-slice CT system with z-flying focal spot.
Flohr, T; Stierstorfer, K; Raupach, R; Ulzheimer, S; Bruder, H
2004-12-01
The meanwhile established generation of 16-slice CT systems enables routine sub-millimeter imaging at short breath-hold times. Clinical progress in the development of multidetector row CT (MDCT) technology beyond 16 slices can more likely be expected from further improvement in spatial and temporal resolution rather than from a mere increase in the speed of volume coverage. We present an evaluation of a recently introduced 64-slice CT system (SOMATOM Sensation 64, Siemens AG, Forchheim, Germany), which uses a periodic motion of the focal spot in longitudinal direction (z-flying focal spot) to double the number of simultaneously acquired slices. This technique acquires 64 overlapping 0.6 mm slices per rotation. The sampling scheme corresponds to that of a 64 x 0.3 mm detector, with the goal of improved longitudinal resolution and reduced spiral artifacts. After an introduction to the detector design, we discuss the basics of z-flying focal spot technology (z-Sharp). We present phantom and specimen scans for performance evaluation. The measured full width at half maximum (FWHM) of the thinnest spiral slice is 0.65 mm. All spiral slice widths are almost independent of the pitch, with deviations of less than 0.1 mm from the nominal value. Using a high-resolution bar pattern phantom (CATPHAN, Phantom Laboratories, Salem, NY), the longitudinal resolution can be demonstrated to be up to 15 lp/cm at the isocenter independent of the pitch, corresponding to a bar diameter of 0.33 mm. Longitudinal resolution is only slightly degraded for off-center locations. At a distance of 100 mm from the isocenter, 14 lp/cm can be resolved in the z-direction, corresponding to a bar diameter of 0.36 mm. Spiral "windmill" artifacts presenting as hyper- and hypodense structures around osseous edges are effectively reduced by the z-flying focal spot technique. Cardiac scanning benefits from the short gantry rotation time of 0.33 s, providing up to 83 ms temporal resolution with 2-segment ECG-gated reconstruction.
Dose coefficients in pediatric and adult abdominopelvic CT based on 100 patient models
NASA Astrophysics Data System (ADS)
Tian, Xiaoyu; Li, Xiang; Segars, W. Paul; Frush, Donald P.; Paulson, Erik K.; Samei, Ehsan
2013-12-01
Recent studies have shown the feasibility of estimating patient dose from a CT exam using CTDIvol-normalized-organ dose (denoted as h), DLP-normalized-effective dose (denoted as k), and DLP-normalized-risk index (denoted as q). However, previous studies were limited to a small number of phantom models. The purpose of this work was to provide dose coefficients (h, k, and q) across a large number of computational models covering a broad range of patient anatomy, age, size percentile, and gender. The study consisted of 100 patient computer models (age range, 0 to 78 y.o.; weight range, 2-180 kg) including 42 pediatric models (age range, 0 to 16 y.o.; weight range, 2-80 kg) and 58 adult models (age range, 18 to 78 y.o.; weight range, 57-180 kg). Multi-detector array CT scanners from two commercial manufacturers (LightSpeed VCT, GE Healthcare; SOMATOM Definition Flash, Siemens Healthcare) were included. A previously-validated Monte Carlo program was used to simulate organ dose for each patient model and each scanner, from which h, k, and q were derived. The relationships between h, k, and q and patient characteristics (size, age, and gender) were ascertained. The differences in conversion coefficients across the scanners were further characterized. CTDIvol-normalized-organ dose (h) showed an exponential decrease with increasing patient size. For organs within the image coverage, the average differences of h across scanners were less than 15%. That value increased to 29% for organs on the periphery or outside the image coverage, and to 8% for distributed organs, respectively. The DLP-normalized-effective dose (k) decreased exponentially with increasing patient size. For a given gender, the DLP-normalized-risk index (q) showed an exponential decrease with both increasing patient size and patient age. The average differences in k and q across scanners were 8% and 10%, respectively. This study demonstrated that the knowledge of patient information and CTDIvol/DLP values may be used to estimate organ dose, effective dose, and risk index in abdominopelvic CT based on the coefficients derived from a large population of pediatric and adult patients.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krafft, S; Court, L; Briere, T
2014-06-15
Purpose: Radiation induced lung damage (RILD) is an important dose-limiting toxicity for patients treated with radiation therapy. Scoring systems for RILD are subjective and limit our ability to find robust predictors of toxicity. We investigate the dose and time-related response for texture-based lung CT image features that serve as potential quantitative measures of RILD. Methods: Pre- and post-RT diagnostic imaging studies were collected for retrospective analysis of 21 patients treated with photon or proton radiotherapy for NSCLC. Total lung and selected isodose contours (0–5, 5–15, 15–25Gy, etc.) were deformably registered from the treatment planning scan to the pre-RT and availablemore » follow-up CT studies for each patient. A CT image analysis framework was utilized to extract 3698 unique texture-based features (including co-occurrence and run length matrices) for each region of interest defined by the isodose contours and the total lung volume. Linear mixed models were fit to determine the relationship between feature change (relative to pre-RT), planned dose and time post-RT. Results: Seventy-three follow-up CT scans from 21 patients (median: 3 scans/patient) were analyzed to describe CT image feature change. At the p=0.05 level, dose affected feature change in 2706 (73.1%) of the available features. Similarly, time affected feature change in 408 (11.0%) of the available features. Both dose and time were significant predictors of feature change in a total of 231 (6.2%) of the extracted image features. Conclusion: Characterizing the dose and time-related response of a large number of texture-based CT image features is the first step toward identifying objective measures of lung toxicity necessary for assessment and prediction of RILD. There is evidence that numerous features are sensitive to both the radiation dose and time after RT. Beyond characterizing feature response, further investigation is warranted to determine the utility of these features as surrogates of clinically significant lung injury.« less