Chapman, Kent; Favaloro, Emmanuel J
2018-05-01
The Multiplate is a popular instrument that measures platelet function using whole blood. Potentially considered a point of care instrument, it is also used by hemostasis laboratories. The instrument is usually utilized to assess antiplatelet medication or as a screen of platelet function. According to the manufacturer, testing should be performed within 0.5-3 hours of blood collection, and preferably using manufacturer provided hirudin tubes. We report time-associated reduction in platelet aggregation using the Multiplate and hirudin blood collection tubes, for all the major employed agonists. Blood for Multiplate analysis was collected into manufacturer supplied hirudin tubes, and 21 consecutive samples assessed using manufacturer supplied agonists (ADP, arachidonic acid, TRAP, collagen and ristocetin), at several time-points post-sample collection within the recommended test time period. Blood was also collected into EDTA as a reference method for platelet counts, with samples collected into sodium citrate and hirudin used for comparative counts. All platelet agonists showed a diminution of response with time. Depending on the agonist, the reduction caused 5-20% and 22-47% of responses initially in the normal reference range to fall below the reference range at 120min and 180min, respectively. Considering any agonist, 35% and 67% of initially "normal" responses became 'abnormal' at 120 min and 180 min, respectively. Platelet counts showed generally minimal changes in EDTA blood, but were markedly reduced over time in both citrate and hirudin blood, with up to 40% and 60% reduction, respectively, at 240 min. The presence of platelet clumping (micro-aggregate formation) was also observed in a time dependent manner, especially for hirudin. In conclusion, considering any platelet agonist, around two-thirds of samples can, within the recommended 0.5-3 hour testing window post-blood collection, yield a reduction in platelet aggregation that may lead to a change in interpretation (i.e., normal to reduced). Thus, the stability of Multiplate testing can more realistically be considered as being between 30-120 min of blood collection for samples collected into hirudin.
Bingley, Polly J; Rafkin, Lisa E; Matheson, Della; Steck, Andrea K; Yu, Liping; Henderson, Courtney; Beam, Craig A; Boulware, David C
2015-12-01
Islet autoantibody testing provides the basis for assessment of risk of progression to type 1 diabetes. We set out to determine the feasibility and acceptability of dried capillary blood spot-based screening to identify islet autoantibody-positive relatives potentially eligible for inclusion in prevention trials. Dried blood spot (DBS) and venous samples were collected from 229 relatives participating in the TrialNet Pathway to Prevention Study. Both samples were tested for glutamic acid decarboxylase, islet antigen 2, and zinc transporter 8 autoantibodies, and venous samples were additionally tested for insulin autoantibodies and islet cell antibodies. We defined multiple autoantibody positive as two or more autoantibodies in venous serum and DBS screen positive if one or more autoantibodies were detected. Participant questionnaires compared the sample collection methods. Of 44 relatives who were multiple autoantibody positive in venous samples, 42 (95.5%) were DBS screen positive, and DBS accurately detected 145 of 147 autoantibody-negative relatives (98.6%). Capillary blood sampling was perceived as more painful than venous blood draw, but 60% of participants would prefer initial screening using home fingerstick with clinic visits only required if autoantibodies were found. Capillary blood sampling could facilitate screening for type 1 diabetes prevention studies.
Rafkin, Lisa E.; Matheson, Della; Steck, Andrea K.; Yu, Liping; Henderson, Courtney; Beam, Craig A.; Boulware, David C.
2015-01-01
Abstract Background: Islet autoantibody testing provides the basis for assessment of risk of progression to type 1 diabetes. We set out to determine the feasibility and acceptability of dried capillary blood spot–based screening to identify islet autoantibody–positive relatives potentially eligible for inclusion in prevention trials. Materials and Methods: Dried blood spot (DBS) and venous samples were collected from 229 relatives participating in the TrialNet Pathway to Prevention Study. Both samples were tested for glutamic acid decarboxylase, islet antigen 2, and zinc transporter 8 autoantibodies, and venous samples were additionally tested for insulin autoantibodies and islet cell antibodies. We defined multiple autoantibody positive as two or more autoantibodies in venous serum and DBS screen positive if one or more autoantibodies were detected. Participant questionnaires compared the sample collection methods. Results: Of 44 relatives who were multiple autoantibody positive in venous samples, 42 (95.5%) were DBS screen positive, and DBS accurately detected 145 of 147 autoantibody-negative relatives (98.6%). Capillary blood sampling was perceived as more painful than venous blood draw, but 60% of participants would prefer initial screening using home fingerstick with clinic visits only required if autoantibodies were found. Conclusions: Capillary blood sampling could facilitate screening for type 1 diabetes prevention studies. PMID:26375197
Gulf War Illness Inflammation Reduction Trial
2015-10-01
study comparing blood samples from Gulf War veterans with and without multiple symptoms of pain, fatigue, and cognitive dysfunction. The goal of the...pilot study was to identify a potential therapeutic target for the treatment of GWI. Examination to the peripheral blood revealed the biomarker...understood. Therefore, we performed a pilot study comparing blood samples from Gulf War veterans who very GWI- with blood 6 from veterans who were
On-chip wavelength multiplexed detection of cancer DNA biomarkers in blood
Cai, H.; Stott, M. A.; Ozcelik, D.; Parks, J. W.; Hawkins, A. R.; Schmidt, H.
2016-01-01
We have developed an optofluidic analysis system that processes biomolecular samples starting from whole blood and then analyzes and identifies multiple targets on a silicon-based molecular detection platform. We demonstrate blood filtration, sample extraction, target enrichment, and fluorescent labeling using programmable microfluidic circuits. We detect and identify multiple targets using a spectral multiplexing technique based on wavelength-dependent multi-spot excitation on an antiresonant reflecting optical waveguide chip. Specifically, we extract two types of melanoma biomarkers, mutated cell-free nucleic acids —BRAFV600E and NRAS, from whole blood. We detect and identify these two targets simultaneously using the spectral multiplexing approach with up to a 96% success rate. These results point the way toward a full front-to-back chip-based optofluidic compact system for high-performance analysis of complex biological samples. PMID:28058082
Coagulation dynamics of a blood sample by multiple scattering analysis
NASA Astrophysics Data System (ADS)
Faivre, Magalie; Peltié, Philippe; Planat-Chrétien, Anne; Cosnier, Marie-Line; Cubizolles, Myriam; Nougier, Christophe; Négrier, Claude; Pouteau, Patrick
2011-05-01
We report a new technique to measure coagulation dynamics on whole-blood samples. The method relies on the analysis of the speckle figure resulting from a whole-blood sample mixed with coagulation reagent and introduced in a thin chamber illuminated with a coherent light. A dynamic study of the speckle reveals a typical behavior due to coagulation. We compare our measured coagulation times to a reference method obtained in a medical laboratory.
Burtis, C.A.; Johnson, W.F.; Walker, W.A.
1985-08-05
A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises: (1) a whole blood sample disc; (2) a serum sample disc; (3) a sample preparation rotor; and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analyticaly rotor for conventional methods. 5 figs.
Burtis, Carl A.; Johnson, Wayne F.; Walker, William A.
1988-01-01
A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises (1) a whole blood sample disc, (2) a serum sample disc, (3) a sample preparation rotor, and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc in capillary tubes filled by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analytical rotor for analysis by conventional methods.
Device and method for automated separation of a sample of whole blood into aliquots
Burtis, Carl A.; Johnson, Wayne F.
1989-01-01
A device and a method for automated processing and separation of an unmeasured sample of whole blood into multiple aliquots of plasma. Capillaries are radially oriented on a rotor, with the rotor defining a sample chamber, transfer channels, overflow chamber, overflow channel, vent channel, cell chambers, and processing chambers. A sample of whole blood is placed in the sample chamber, and when the rotor is rotated, the blood moves outward through the transfer channels to the processing chambers where the blood is centrifugally separated into a solid cellular component and a liquid plasma component. When the rotor speed is decreased, the plasma component backfills the capillaries resulting in uniform aliquots of plasma which may be used for subsequent analytical procedures.
Wickremsinhe, Enaksha R; Perkins, Everett J
2015-03-01
Traditional pharmacokinetic analysis in nonclinical studies is based on the concentration of a test compound in plasma and requires approximately 100 to 200 μL blood collected per time point. However, the total blood volume of mice limits the number of samples that can be collected from an individual animal-often to a single collection per mouse-thus necessitating dosing multiple mice to generate a pharmacokinetic profile in a sparse-sampling design. Compared with traditional methods, dried blood spot (DBS) analysis requires smaller volumes of blood (15 to 20 μL), thus supporting serial blood sampling and the generation of a complete pharmacokinetic profile from a single mouse. Here we compare plasma-derived data with DBS-derived data, explain how to adopt DBS sampling to support discovery mouse studies, and describe how to generate pharmacokinetic and pharmacodynamic data from a single mouse. Executing novel study designs that use DBS enhances the ability to identify and streamline better drug candidates during drug discovery. Implementing DBS sampling can reduce the number of mice needed in a drug discovery program. In addition, the simplicity of DBS sampling and the smaller numbers of mice needed translate to decreased study costs. Overall, DBS sampling is consistent with 3Rs principles by achieving reductions in the number of animals used, decreased restraint-associated stress, improved data quality, direct comparison of interanimal variability, and the generation of multiple endpoints from a single study.
Wickremsinhe, Enaksha R; Perkins, Everett J
2015-01-01
Traditional pharmacokinetic analysis in nonclinical studies is based on the concentration of a test compound in plasma and requires approximately 100 to 200 µL blood collected per time point. However, the total blood volume of mice limits the number of samples that can be collected from an individual animal—often to a single collection per mouse—thus necessitating dosing multiple mice to generate a pharmacokinetic profile in a sparse-sampling design. Compared with traditional methods, dried blood spot (DBS) analysis requires smaller volumes of blood (15 to 20 µL), thus supporting serial blood sampling and the generation of a complete pharmacokinetic profile from a single mouse. Here we compare plasma-derived data with DBS-derived data, explain how to adopt DBS sampling to support discovery mouse studies, and describe how to generate pharmacokinetic and pharmacodynamic data from a single mouse. Executing novel study designs that use DBS enhances the ability to identify and streamline better drug candidates during drug discovery. Implementing DBS sampling can reduce the number of mice needed in a drug discovery program. In addition, the simplicity of DBS sampling and the smaller numbers of mice needed translate to decreased study costs. Overall, DBS sampling is consistent with 3Rs principles by achieving reductions in the number of animals used, decreased restraint-associated stress, improved data quality, direct comparison of interanimal variability, and the generation of multiple endpoints from a single study. PMID:25836959
Kuan, Da-Han; Wang, I-Shun; Lin, Jiun-Rue; Yang, Chao-Han; Huang, Chi-Hsien; Lin, Yen-Hung; Lin, Chih-Ting; Huang, Nien-Tsu
2016-08-02
The hemoglobin-A1c test, measuring the ratio of glycated hemoglobin (HbA1c) to hemoglobin (Hb) levels, has been a standard assay in diabetes diagnosis that removes the day-to-day glucose level variation. Currently, the HbA1c test is restricted to hospitals and central laboratories due to the laborious, time-consuming whole blood processing and bulky instruments. In this paper, we have developed a microfluidic device integrating dual CMOS polysilicon nanowire sensors (MINS) for on-chip whole blood processing and simultaneous detection of multiple analytes. The micromachined polymethylmethacrylate (PMMA) microfluidic device consisted of a serpentine microchannel with multiple dam structures designed for non-lysed cells or debris trapping, uniform plasma/buffer mixing and dilution. The CMOS-fabricated polysilicon nanowire sensors integrated with the microfluidic device were designed for the simultaneous, label-free electrical detection of multiple analytes. Our study first measured the Hb and HbA1c levels in 11 clinical samples via these nanowire sensors. The results were compared with those of standard Hb and HbA1c measurement methods (Hb: the sodium lauryl sulfate hemoglobin detection method; HbA1c: cation-exchange high-performance liquid chromatography) and showed comparable outcomes. Finally, we successfully demonstrated the efficacy of the MINS device's on-chip whole blood processing followed by simultaneous Hb and HbA1c measurement in a clinical sample. Compared to current Hb and HbA1c sensing instruments, the MINS platform is compact and can simultaneously detect two analytes with only 5 μL of whole blood, which corresponds to a 300-fold blood volume reduction. The total assay time, including the in situ sample processing and analyte detection, was just 30 minutes. Based on its on-chip whole blood processing and simultaneous multiple analyte detection functionalities with a lower sample volume requirement and shorter process time, the MINS device can be effectively applied to real-time diabetes diagnostics and monitoring in point-of-care settings.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Byung-Kook; Kim, Yangho, E-mail: yanghokm@nuri.net
Introduction: We present data on the association of manganese (Mn) level with hypertension in a representative sample of the adult Korean population who participated in the Korean National Health and Nutrition Examination Survey (KNHANES) 2008. Methods: This study was based on the data obtained by KNHANES 2008, which was conducted for three years (2007-2009) using a rolling sampling design involving a complex, stratified, multistage, probability-cluster survey of a representative sample of the noninstitutionalized civilian population of South Korea. Results: Multiple regression analysis after controlling for covariates, including gender, age, regional area, education level, smoking, drinking status, hemoglobin, and serum creatinine,more » showed that the beta coefficients of log blood Mn were 3.514, 1.878, and 2.517 for diastolic blood pressure, and 3.593, 2.449, and 2.440 for systolic blood pressure in female, male, and all participants, respectively. Multiple regression analysis including three other blood metals, lead, mercury, and cadmium, revealed no significant effects of the three metals on blood pressure and showed no effect on the association between blood Mn and blood pressure. In addition, doubling the blood Mn increased the risk of hypertension 1.828, 1.573, and 1.567 fold in women, men, and all participants, respectively, after adjustment for covariates. The addition of blood lead, mercury, and cadmium as covariates did not affect the association between blood Mn and the prevalence of hypertension. Conclusion: Blood Mn level was associated with an increased risk of hypertension in a representative sample of the Korean adult population. - Highlights: {yields} We showed the association of manganese with hypertension in Korean population. {yields} This study was based on the data obtained by KNHANES 2008. {yields} Blood manganese level was associated with an increased risk of hypertension.« less
ERIC Educational Resources Information Center
Whitehouse, Andrew J. O.; Mattes, Eugen; Maybery, Murray T.; Sawyer, Michael G.; Jacoby, Peter; Keelan, Jeffrey A.; Hickey, Martha
2012-01-01
Background: Preliminary evidence suggests that prenatal testosterone exposure may be associated with language delay. However, no study has examined a large sample of children at multiple time-points. Methods: Umbilical cord blood samples were obtained at 861 births and analysed for bioavailable testosterone (BioT) concentrations. When…
Chambers, Andrew G.; Percy, Andrew J.; Yang, Juncong; Camenzind, Alexander G.; Borchers, Christoph H.
2013-01-01
Dried blood spot (DBS) sampling, coupled with multiple reaction monitoring mass spectrometry (MRM-MS), is a well-established approach for quantifying a wide range of small molecule biomarkers and drugs. This sampling procedure is simpler and less-invasive than those required for traditional plasma or serum samples enabling collection by minimally trained personnel. Many analytes are stable in the DBS format without refrigeration, which reduces the cost and logistical challenges of sample collection in remote locations. These advantages make DBS sample collection desirable for advancing personalized medicine through population-wide biomarker screening. Here we expand this technology by demonstrating the first multiplexed method for the quantitation of endogenous proteins in DBS samples. A panel of 60 abundant proteins in human blood was targeted by monitoring proteotypic tryptic peptides and their stable isotope-labeled analogs by MRM. Linear calibration curves were obtained for 40 of the 65 peptide targets demonstrating multiple proteins can be quantitatively extracted from DBS collection cards. The method was also highly reproducible with a coefficient of variation of <15% for all 40 peptides. Overall, this assay quantified 37 proteins spanning a range of more than four orders of magnitude in concentration within a single 25 min LC/MRM-MS analysis. The protein abundances of the 33 proteins quantified in matching DBS and whole blood samples showed an excellent correlation, with a slope of 0.96 and an R2 value of 0.97. Furthermore, the measured concentrations for 80% of the proteins were stable for at least 10 days when stored at −20 °C, 4 °C and 37 °C. This work represents an important first step in evaluating the integration of DBS sampling with highly-multiplexed MRM for quantitation of endogenous proteins. PMID:23221968
Delvaux, Elaine; Mastroeni, Diego; Nolz, Jennifer; Chow, Nienwen; Sabbagh, Marwan; Caselli, Richard J; Reiman, Eric M; Marshall, Frederick J; Coleman, Paul D
2017-10-01
The need for a reliable, simple, and inexpensive blood test for Alzheimer's disease (AD) suitable for use in a primary care setting is widely recognized. This has led to a large number of publications describing blood tests for AD, which have, for the most part, not been replicable. We have chosen to examine transcripts expressed by the cellular, leukocyte compartment of blood. We have used hypothesis-based cDNA arrays and quantitative PCR to quantify the expression of selected sets of genes followed by multivariate analyses in multiple independent samples. Rather than a single study with no replicates, we chose an experimental design in which there were multiple replicates using different platforms and different sample populations. We have divided 177 blood samples and 27 brain samples into multiple replicates to demonstrate the ability to distinguish early clinical AD (Clinical Dementia Rating scale 0.5), Parkinson's disease (PD), and cognitively unimpaired APOE4 homozygotes, as well as to determine persons at risk for future cognitive impairment with significant accuracy. We assess our methods in a training/test set and also show that the variables we use distinguish AD, PD, and control brain. Importantly, we describe the variability of the weights assigned to individual transcripts in multivariate analyses in repeated studies and suggest that the variability we describe may be the cause of inability to repeat many earlier studies. Our data constitute a proof of principle that multivariate analysis of the transcriptome related to cell stress and inflammation of peripheral blood leukocytes has significant potential as a minimally invasive and inexpensive diagnostic tool for diagnosis and early detection of risk for AD. Copyright © 2017 Elsevier Inc. All rights reserved.
Quantification of multiple elements in dried blood spot samples.
Pedersen, Lise; Andersen-Ranberg, Karen; Hollergaard, Mads; Nybo, Mads
2017-08-01
Dried blood spots (DBS) is a unique matrix that offers advantages compared to conventional blood collection making it increasingly popular in large population studies. We here describe development and validation of a method to determine multiple elements in DBS. Elements were extracted from punches and analyzed using inductively coupled plasma-mass spectrometry (ICP-MS). The method was evaluated with quality controls with defined element concentration and blood spiked with elements to assess accuracy and imprecision. DBS element concentrations were compared with concentrations in venous blood. Samples with different hematocrit were spotted onto filter paper to assess hematocrit effect. The established method was precise and accurate for measurement of most elements in DBS. There was a significant but relatively weak correlation between measurement of the elements Mg, K, Fe, Cu, Zn, As and Se in DBS and venous whole blood. Hematocrit influenced the DBS element measurement, especially for K, Fe and Zn. Trace elements can be measured with high accuracy and low imprecision in DBS, but contribution of signal from the filter paper influences measurement of some elements present at low concentrations. Simultaneous measurement of K and Fe in DBS extracts may be used to estimate sample hematocrit. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Ranjbaran, Mina; Kadkhodaee, Mehri; Seifi, Behjat; Mirzaei, Reza; Ahghari, Parisa
2018-01-01
Hemorrhagic shock (HS) still has a high mortality rate and none of the known resuscitative regimens completely reverse its adverse outcomes. This study investigated the effects of different models of resuscitative therapy on the healing of organ damage in a HS model. Male Wistar rats were randomized into six groups: Sham, without HS induction; HS, without resuscitation; HS+Blood, resuscitation with the shed blood; HS+Blood+NS, resuscitation with blood and normal saline; HS+Blood+RL, resuscitation with blood and Ringer's lactate; EPO, erythropoietin was added to the blood and RL. Blood and urine samples were obtained 3 h after resuscitation. Kidney, liver and brain tissue samples were harvested for multiple organ failure evaluation. Survival rate was the highest in the Sham, EPO and HS+Blood+RL groups compared to others. Plasma creatinine concentration, ALT, AST, urinary NAG activity and renal NGAL mRNA expression significantly increased in the HS+Blood+RL group compared to the Sham group. There was a significant increase in tissue oxidative stress markers and pro-inflammatory cytokines in HS+Blood+RL group compared to the Sham rats. EPO had more protective effects on multiple organ failure compared to the HS+Blood+RL group. EPO, as a resuscitative treatment, attenuated HS-induced organ damage. It seems that it has a potential to be attractive for clinical trials.
Extensive monitoring through multiple blood samples in professional soccer players.
Heisterberg, Mette F; Fahrenkrug, Jan; Krustrup, Peter; Storskov, Anders; Kjær, Michael; Andersen, Jesper L
2013-05-01
The aim of this study was to make a comprehensive gathering of consecutive detailed blood samples from professional soccer players and to analyze different blood parameters in relation to seasonal changes in training and match exposure. Blood samples were collected 5 times during a 6-month period and analyzed for 37 variables in 27 professional soccer players from the best Danish league. Additionally, the players were tested for body composition, V[Combining Dot Above]O2max and physical performance by the Yo-Yo intermittent endurance submax test (IE2). Multiple variations in blood parameters occurred during the observation period, including a decrease in hemoglobin and an increase in hematocrit as the competitive season progressed. Iron and transferrin were stable, whereas ferritin showed a decrease at the end of the season. The immunoglobulin A (IgA) and IgM increased in the period with basal physical training and at the end of the season. Leucocytes decreased with increased physical training. Lymphocytes decreased at the end of the season. The V[Combining Dot Above]O2max decreased toward the end of the season, whereas no significant changes were observed in the IE2 test. The regular blood samples from elite soccer players reveal significant changes that may be related to changes in training pattern, match exposure, or length of the match season. Especially the end of the preparation season and at the end of the competitive season seem to be time points were the blood-derived values indicate that the players are under excessive physical strain and might be more subjected to a possible overreaching-overtraining conditions. We suggest that regular analyses of blood samples could be an important initiative to optimize training adaptation, training load, and game participation, but sampling has to be regular, and a database has to be built for each individual player.
The Antimicrobial Peptide Lysozyme Is Induced after Multiple Trauma
Klüter, Tim; Fitschen-Oestern, Stefanie; Lippross, Sebastian; Weuster, Matthias; Pufe, Thomas; Tohidnezhad, Mersedeh; Beyer, Andreas; Seekamp, Andreas; Varoga, Deike
2014-01-01
The antimicrobial peptide lysozyme is an important factor of innate immunity and exerts high potential of antibacterial activity. In the present study we evaluated the lysozyme expression in serum of multiple injured patients and subsequently analyzed their possible sources and signaling pathways. Expression of lysozyme was examined in blood samples of multiple trauma patients from the day of trauma until 14 days after trauma by ELISA. To investigate major sources of lysozyme, its expression and regulation in serum samples, different blood cells, and tissue samples were analysed by ELISA and real-time PCR. Neutrophils and hepatocytes were stimulated with cytokines and supernatant of Staphylococcus aureus. The present study demonstrates the induction and release of lysozyme in serum of multiple injured patients. The highest lysozyme expression of all tested cells and tissues was detected in neutrophils. Stimulation with trauma-related factors such as interleukin-6 and S. aureus induced lysozyme expression. Liver tissue samples of patients without trauma show little lysozyme expression compared to neutrophils. After stimulation with bacterial fragments, lysozyme expression of hepatocytes is upregulated significantly. Toll-like receptor 2, a classic receptor of Gram-positive bacterial protein, was detected as a possible target for lysozyme induction. PMID:25258475
PBDES IN US HUMANS, FOOD, AND ENVIRONMENTAL SAMPLES
Polybrominated diphenyl ether (PBDE) flame retardants were measured in US human milk and blood, food and environmental samples. All 59 milk samples were positive for multiple congeners measured. Milk was collected beginning in 2001 from various locations in the US. PBDEs varied f...
Multiple-wavelength spectroscopic quantitation of light-absorbing species in scattering media
Nathel, Howard; Cartland, Harry E.; Colston, Jr., Billy W.; Everett, Matthew J.; Roe, Jeffery N.
2000-01-01
An oxygen concentration measurement system for blood hemoglobin comprises a multiple-wavelength low-coherence optical light source that is coupled by single mode fibers through a splitter and combiner and focused on both a target tissue sample and a reference mirror. Reflections from both the reference mirror and from the depths of the target tissue sample are carried back and mixed to produce interference fringes in the splitter and combiner. The reference mirror is set such that the distance traversed in the reference path is the same as the distance traversed into and back from the target tissue sample at some depth in the sample that will provide light attenuation information that is dependent on the oxygen in blood hemoglobin in the target tissue sample. Two wavelengths of light are used to obtain concentrations. The method can be used to measure total hemoglobin concentration [Hb.sub.deoxy +Hb.sub.oxy ] or total blood volume in tissue and in conjunction with oxygen saturation measurements from pulse oximetry can be used to absolutely quantify oxyhemoglobin [HbO.sub.2 ] in tissue. The apparatus and method provide a general means for absolute quantitation of an absorber dispersed in a highly scattering medium.
Rapid measurement of fibrinogen concentration in whole blood using a steel ball coagulometer
Schlimp, Christoph J.; Khadem, Anna; Klotz, Anton; Solomon, Cristina; Hochleitner, Gerald; Ponschab, Martin; Redl, Heinz; Schöchl, Herbert
2015-01-01
BACKGROUND Fibrinogen plays a key role in hemostasis and is the first coagulation factor to reach critical levels in bleeding patients. Current European guidelines on the management of traumatic or perioperative bleeding recommend fibrinogen supplementation at specific threshold levels. Whole blood viscoelastic tests provide fast evaluation of fibrin deficits. Fast measurement of plasma fibrinogen concentration is not yet available. We investigated a method to rapidly determine whole blood fibrinogen concentration using standard Clauss assays and a steel ball coagulometer and provide an estimate of the “plasma-equivalent” fibrinogen concentration within minutes by adjustment of the measured whole blood fibrinogen concentration with a quickly measureable hemoglobin-derived hematocrit. METHODS The feasibility of this approach was tested with a Clauss assay using multiple porcine fresh blood samples obtained during in vivo bleeding, hemodilution, and after treatment with hemostatic therapy. Two different Clauss assays were then tested using multiple human volunteers’ blood samples diluted in vitro and supplemented with fibrinogen concentrate. Comparative measurements with fibrin-based thromboelastometry tests were performed. RESULTS Regression and Bland-Altman analyses of derived “plasma-equivalent” fibrinogen and measured plasma fibrinogen concentration was excellent in porcine and human blood samples, especially in the ranges relevant to traumatic or perioperative bleeding. CONCLUSION Fast whole blood fibrinogen measurements could be considered as an alternative to plasma fibrinogen measurement for acute bleeding management in trauma and perioperative care settings. Further studies are needed to prove this concept and determine the turnaround times for its clinical application in emergency departments and operating theaters. PMID:25742256
Co-infection with arthropod-borne pathogens in domestic cats.
André, Marcos Rogério; Filgueira, Kilder Dantas; Calchi, Ana Cláudia; Sousa, Keyla Carstens Marques de; Gonçalves, Luiz Ricardo; Medeiros, Vitor Brasil; Ximenes, Poliana Araújo; Lelis, Ivana Cristina Nunes Gadelha; Meireles, Maria Vanuza Nunes de; Machado, Rosangela Zacarias
2017-01-01
The role of several feline vector-borne pathogens (FVBP) as a cause of disease in cats has not been clearly determined. In fact, with the exception of Bartonella spp. and hemoplasmas, FVBP in cats has not been clearly determined in Brazil yet. The present study aimed at identifying, by using molecular methods, the presence of FVBP in three cats showing non-specific clinical signs and inclusions suggestive of hemoparasites in blood smears. Cytauxzoon felis, 'Candidatus Mycoplasma haemominutum', Ehrlichia sp. closely related to Ehrlichia canis, and Anaplasma sp. closely related to Anaplasma phagocytophilum were detected in blood samples from two out of three sampled cats. Both cats positive for multiple FVBP did not show hematological and biochemical abnormalities. The present work emphasizes the need for molecular confirmation of co-infection by multiple FVBP in cats presenting non-specific clinical signs and inclusions resembling hemoparasites in blood smears.
Lacerda, Eliana M.; Bowman, Erinna W.; Cliff, Jacqueline M.; Kingdon, Caroline C.; King, Elizabeth C.; Lee, Ji-Sook; Clark, Taane G.; Dockrell, Hazel M.; Riley, Eleanor M.; Curran, Hayley; Nacul, Luis
2017-01-01
The UK ME/CFS Biobank was launched in August 2011 following extensive consultation with professionals and patient representatives. The bioresource aims to enhance research on myalgic encephalomyelitis/chronic fatigue syndrome (ME/CFS), related to pathophysiology, biomarkers and therapeutic approaches. The cohort includes 18–60 year olds, encompassing 284 clinically-confirmed ME/CFS cases, 60 neurologist-diagnosed multiple sclerosis (MS) cases, and 135 healthy individuals. The Biobank contains blood samples, aliquoted into serum, plasma, peripheral blood mononuclear cells (PBMC), red blood cells/granulocyte pellet, whole blood, and RNA (totalling 29,863 aliquots). Extensive dataset (700 clinical and socio-demographic variables/participant) enables comprehensive phenotyping. Potential reuse is conditional to ethical approval. PMID:28649428
Lacerda, Eliana M; Bowman, Erinna W; Cliff, Jacqueline M; Kingdon, Caroline C; King, Elizabeth C; Lee, Ji-Sook; Clark, Taane G; Dockrell, Hazel M; Riley, Eleanor M; Curran, Hayley; Nacul, Luis
2017-01-01
The UK ME/CFS Biobank was launched in August 2011 following extensive consultation with professionals and patient representatives. The bioresource aims to enhance research on myalgic encephalomyelitis/chronic fatigue syndrome (ME/CFS), related to pathophysiology, biomarkers and therapeutic approaches. The cohort includes 18-60 year olds, encompassing 284 clinically-confirmed ME/CFS cases, 60 neurologist-diagnosed multiple sclerosis (MS) cases, and 135 healthy individuals. The Biobank contains blood samples, aliquoted into serum, plasma, peripheral blood mononuclear cells (PBMC), red blood cells/granulocyte pellet, whole blood, and RNA (totalling 29,863 aliquots). Extensive dataset (700 clinical and socio-demographic variables/participant) enables comprehensive phenotyping. Potential reuse is conditional to ethical approval.
Human blood metabolite timetable indicates internal body time
Kasukawa, Takeya; Sugimoto, Masahiro; Hida, Akiko; Minami, Yoichi; Mori, Masayo; Honma, Sato; Honma, Ken-ichi; Mishima, Kazuo; Soga, Tomoyoshi; Ueda, Hiroki R.
2012-01-01
A convenient way to estimate internal body time (BT) is essential for chronotherapy and time-restricted feeding, both of which use body-time information to maximize potency and minimize toxicity during drug administration and feeding, respectively. Previously, we proposed a molecular timetable based on circadian-oscillating substances in multiple mouse organs or blood to estimate internal body time from samples taken at only a few time points. Here we applied this molecular-timetable concept to estimate and evaluate internal body time in humans. We constructed a 1.5-d reference timetable of oscillating metabolites in human blood samples with 2-h sampling frequency while simultaneously controlling for the confounding effects of activity level, light, temperature, sleep, and food intake. By using this metabolite timetable as a reference, we accurately determined internal body time within 3 h from just two anti-phase blood samples. Our minimally invasive, molecular-timetable method with human blood enables highly optimized and personalized medicine. PMID:22927403
Does whole blood coagulation analysis reflect developmental haemostasis?
Ravn, Hanne Berg; Andreasen, Jo Bønding; Hvas, Anne-Mette
2017-04-01
: Developmental haemostasis has been well documented over the last 3 decades and age-dependent reference ranges have been reported for a number of plasmatic coagulation parameters. With the increasing use of whole blood point-of-care tests like rotational thromboelastometry (ROTEM) and platelet function tests, an evaluation of age-dependent changes is warranted for these tests as well. We obtained blood samples from 149 children, aged 1 day to 5.9 years, and analysed conventional plasmatic coagulation tests, including activated partial prothrombin time, prothrombin time, and fibrinogen (functional). Whole blood samples were analysed using ROTEM to assess overall coagulation capacity and Multiplate analyzer to evaluate platelet aggregation. Age-dependent changes were analysed for all variables. We found age-dependent differences in all conventional coagulation tests (all P values < 0.05), but there was no sign of developmental changes in whole blood coagulation assessment when applying ROTEM, apart from clotting time in the EXTEM assay (P < 0.03). Despite marked differences in mean platelet aggregation between age groups, data did not reach statistical significance. Citrate-anticoagulated blood showed significantly reduced platelet aggregation compared with blood anticoagulated with heparin or hirudin (all P values < 0.003). We confirmed previous developmental changes in conventional plasmatic coagulation test. However, these age-dependent changes were not displayed in whole blood monitoring using ROTEM or Multiplate analyzer. Type of anticoagulant had a significant influence on platelet aggregation across all age groups.
Korfmacher, Walter; Luo, Yongyi; Ho, Stacy; Sun, Wei; Shen, Liduo; Wang, Jie; Wu, Zhongtao; Guo, Yang; Snow, Gregory; O'Shea, Thomas
2015-01-01
Serial sampling methods have been used for rat pharmacokinetic (PK) studies for over 20 years. Currently, it is still common to take 200-250 μL of blood at each timepoint when performing a PK study in rats and using serial sampling. While several techniques have been employed for collecting blood samples from rats, there is only limited published data to compare these methods. Recently, microsampling (≤ 50 μL) techniques have been reported as an alternative process for collecting blood samples from rats. In this report, five compounds were dosed orally into rats. For three proprietary compounds, jugular vein cannula (JVC) sampling was used to collect whole blood and plasma samples and capillary microsampling (CMS) was used to collect blood samples from the tail vein of the same animal. For the two other compounds, marketed drugs fluoxetine and glipizide, JVC sampling was used to collect both whole blood and blood CMS samples while tail-vein sampling from the same rats was also used to collect both whole blood and blood CMS samples. For the three proprietary compounds, the blood AUC as well as the blood concentration-time profile that were obtained from the tail vein were different from those obtained via JVC sampling. For fluoxetine, the blood total exposure (AUC) was not statistically different when comparing tail-vein sampling to JVC sampling, however the blood concentration-time profile that was obtained from the tail vein was different than the one obtained from JVC sampling. For glipizide, the blood AUC and concentration-time profile were not statistically different when comparing the tail-vein sampling to the JVC sampling. For both fluoxetine and glipizide, the blood concentration profiles obtained from CMS were equivalent to the blood concentration profiles obtained from the standard whole blood sampling, collected at the same sampling site. The data in this report provide strong evidence that blood CMS is a valuable small volume blood sampling approach for rats and that it provides results for test compound concentrations that are equivalent to those obtained from traditional whole blood sampling. The data also suggest that for some compounds, the concentration-time profile that is obtained for a test compound based on sampling from a rat tail vein may be different from that obtained from rat JVC sampling. In some cases, this shift in the concentration-time profile will result in different PK parameters for the test compound. Based on these observations, it is recommended that a consistent blood sampling method should be used for serial microsampling in discovery rat PK studies when testing multiple new chemical entities. If the rat tail vein sampling method is selected for PK screening, then conducting a bridging study on the lead compound is recommended to confirm that the rat PK obtained from JVC sampling is comparable to the tail-vein sampling. Copyright © 2015 Elsevier Inc. All rights reserved.
Cordón, G Pérez; Prados, A Hitos; Romero, D; Moreno, M Sánchez; Pontes, A; Osuna, A; Rosales, M J
2009-11-12
Birds from the Almuñecar ornithological garden (Granada, Spain) were surveyed from June 2006 to May 2007 to establish programmes to prevent, control, and treat intestinal and haematic parasites. A total of 984 faecal samples and 41 samples of blood were collected from Psittacidae, Cacatuidae, Phasianidae, and Anatidae. One or more intestinal parasites were identified in 51.6% of the samples. Blood parasites were found in 26.8% of the birds examined. The most frequent pathogenic endoparasites were coccidians, such as Cyclospora sp. (4.5%), Eimeria sp. (4.1%) and Isospora sp. (2%) and helminths such as Capillaria sp. (10. 1%), Ascaridia sp. (4.9%) and Heterakis gallinarum (4.9%). All the parasites varied with season but the most were found year round. Multiple parasitic infections by intestinal parasites were common, with 196 of 984 faecal samples having 2-5 intestinal parasites. The most frequent cases of multiple parasitism were Blastocystis plus Entamoeba sp. and Blastocystis plus Cyclospora sp. The haematic protozoa detected were Haemoproteus sp. (17%) and Plasmodium sp. (7.3%). Multiple parasitism by Haemoproteus sp. and Plasmodium sp. was detected in 1 sample of Gallus gallus. After each sampling, some of the affected animals were treated according to our results, and the corresponding programmes of prevention and control were designed.
Karumaa, Santra; Kärpänoja, Pauliina; Sarkkinen, Hannu
2012-03-01
We have evaluated the GenoType blood culture assay (Hain Lifescience, Nehren, Germany) for the identification of bacteria in 233 positive blood cultures and assessed its suitability in the workflow of a routine microbiology laboratory. In 68/233 (29.2%) samples, the culture result could not be confirmed by the GenoType assay due to a lack of primers in the test, multiple organisms in the sample, or inconsistency with respect to the identification by culture. Although the GenoType blood culture assay gives satisfactory results for bacteria for which primers are available, there are difficulties in applying the test in the routine microbiology laboratory.
van Ginkel, Joost H; van den Broek, Daan A; van Kuik, Joyce; Linders, Dorothé; de Weger, Roel; Willems, Stefan M; Huibers, Manon M H
2017-10-01
In current molecular cancer diagnostics, using blood samples of cancer patients for the detection of genetic alterations in plasma (cell-free) circulating tumor DNA (ctDNA) is an emerging practice. Since ctDNA levels in blood are low, highly sensitive Droplet Digital PCR (ddPCR) can be used for detecting rare mutational targets. In order to perform ddPCR on blood samples, a standardized procedure for processing and analyzing blood samples is necessary to facilitate implementation into clinical practice. Therefore, we assessed the technical sample workup procedure for ddPCR on blood plasma samples. Blood samples from healthy individuals, as well as lung cancer patients were analyzed. We compared different methods and protocols for sample collection, storage, centrifugation, isolation, and quantification. Cell-free DNA (cfDNA) concentrations of several wild-type targets and BRAF and EGFR-mutant ctDNA concentrations quantified by ddPCR were primary outcome measurements. Highest cfDNA concentrations were measured in blood collected in serum tubes. No significant differences in cfDNA concentrations were detected between various time points of up to 24 h until centrifugation. Highest cfDNA concentrations were detected after DNA isolation with the Quick cfDNA Serum & Plasma Kit, while plasma isolation using the QIAamp Circulating Nucleic Acid Kit yielded the most consistent results. DdPCR results on cfDNA are highly dependent on multiple factors during preanalytical sample workup, which need to be addressed during the development of this diagnostic tool for cancer diagnostics in the future. © 2017 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.
Multiplexed Affinity-Based Separation of Proteins and Cells Using Inertial Microfluidics.
Sarkar, Aniruddh; Hou, Han Wei; Mahan, Alison E; Han, Jongyoon; Alter, Galit
2016-03-30
Isolation of low abundance proteins or rare cells from complex mixtures, such as blood, is required for many diagnostic, therapeutic and research applications. Current affinity-based protein or cell separation methods use binary 'bind-elute' separations and are inefficient when applied to the isolation of multiple low-abundance proteins or cell types. We present a method for rapid and multiplexed, yet inexpensive, affinity-based isolation of both proteins and cells, using a size-coded mixture of multiple affinity-capture microbeads and an inertial microfluidic particle sorter device. In a single binding step, different targets-cells or proteins-bind to beads of different sizes, which are then sorted by flowing them through a spiral microfluidic channel. This technique performs continuous-flow, high throughput affinity-separation of milligram-scale protein samples or millions of cells in minutes after binding. We demonstrate the simultaneous isolation of multiple antibodies from serum and multiple cell types from peripheral blood mononuclear cells or whole blood. We use the technique to isolate low abundance antibodies specific to different HIV antigens and rare HIV-specific cells from blood obtained from HIV+ patients.
NASA Astrophysics Data System (ADS)
Qasaimeh, Mohammad A.; Wu, Yichao C.; Bose, Suman; Menachery, Anoop; Talluri, Srikanth; Gonzalez, Gabriel; Fulciniti, Mariateresa; Karp, Jeffrey M.; Prabhala, Rao H.; Karnik, Rohit
2017-04-01
The necessity for bone marrow aspiration and the lack of highly sensitive assays to detect residual disease present challenges for effective management of multiple myeloma (MM), a plasma cell cancer. We show that a microfluidic cell capture based on CD138 antigen, which is highly expressed on plasma cells, permits quantitation of rare circulating plasma cells (CPCs) in blood and subsequent fluorescence-based assays. The microfluidic device is based on a herringbone channel design, and exhibits an estimated cell capture efficiency of ~40-70%, permitting detection of <10 CPCs/mL using 1-mL sample volumes, which is difficult using existing techniques. In bone marrow samples, the microfluidic-based plasma cell counts exhibited excellent correlation with flow cytometry analysis. In peripheral blood samples, the device detected a baseline of 2-5 CD138+ cells/mL in healthy donor blood, with significantly higher numbers in blood samples of MM patients in remission (20-24 CD138+ cells/mL), and yet higher numbers in MM patients exhibiting disease (45-184 CD138+ cells/mL). Analysis of CPCs isolated using the device was consistent with serum immunoglobulin assays that are commonly used in MM diagnostics. These results indicate the potential of CD138-based microfluidic CPC capture as a useful ‘liquid biopsy’ that may complement or partially replace bone marrow aspiration.
Martin, Paul; Cheung, S Y Amy; Yen, Mark; Han, David; Gillen, Michael
2016-01-01
The aims of the present study were to characterize the pharmacokinetics of fostamatinib in two phase I studies in healthy Japanese subjects after single- and multiple-dose administration, and to evaluate the utility of dried blood spot (DBS) sampling. In study A, 40 Japanese and 16 white subjects were randomized in a double-blind parallel group study consisting of seven cohorts, which received either placebo or a fostamatinib dose between 50 and 200 mg after single and multiple dosing. Pharmacokinetics of R406 (active metabolite of fostamatinib) in plasma and urine was assessed, and safety was intensively monitored. Study B was an open-label study that assessed fostamatinib 100 and 200 mg in 24 Japanese subjects. In addition to plasma and urine sampling (as for study A), pharmacokinetics was also assessed in blood. Mean maximum plasma concentration (C max) and area under total plasma concentration–time curve (AUC) increased with increasing dose in Japanese subjects. Steady state was achieved in 5–7 days for all doses. C max and AUC were both higher in Japanese subjects administered a 150-mg single dose than in white subjects. This difference was maintained for steady state exposure by day 10. Overall, R406 blood concentrations were consistent and ∼2.5-fold higher than in plasma. Minimal (<0.1 %) R406 was excreted in urine. Fostamatinib was well tolerated at all doses. Fostamatinib pharmacokinetics following single- and multiple-dose administration was approximately dose proportional at all doses ≤150 mg and greater than dose proportional at 200 mg in Japanese subjects. Japanese subjects administered fostamatinib 150 mg had higher exposure than white subjects. R406 could be measured in DBS samples and distributed into red blood cells, and DBS sampling was a useful method for assessing R406 pharmacokinetics.
Ramey, Andy M.; Schmutz, Joel A.; Fleskes, Joseph P.; Yabsley, Michael J.
2013-01-01
Information on the molecular detection of hematozoa from different tissue types and multiple years would be useful to inform sample collection efforts and interpret results of meta-analyses or investigations spanning multiple seasons. In this study, we tested blood and muscle tissue collected from northern pintails (Anas acuta) during autumn and winter of different years to evaluate prevalence and genetic diversity ofLeucocytozoon, Haemoproteus, and Plasmodium infections in this abundant waterfowl species of the Central Valley of California. We first compared results for paired blood and wing muscle samples to assess the utility of different tissue types for molecular investigations of haemosporidian parasites. Second, we explored inter-annual variability of hematozoa infection in Central Valley northern pintails and investigated possible effects of age, sex, and sub-region of sample collection on estimated parasite detection probability and prevalence. We found limited evidence for differences between tissue types in detection probability and prevalence ofLeucocytozoon, Haemoproteus, and Plasmodium parasites, which supports the utility of both sample types for obtaining information on hematozoan infections. However, we detected 11 haemosporidian mtDNA cyt bhaplotypes in blood samples vs. six in wing muscle tissue collected during the same sample year suggesting an advantage to using blood samples for investigations of genetic diversity. Estimated prevalence ofLeucocytozoon parasites was greater during 2006–2007 as compared to 2011–2012 and four unique haemosporidian mtDNA cyt b haplotypes were detected in the former sample year but not in the latter. Seven of 15 mtDNA cyt b haplotypes detected in northern pintails had 100% identity with previously reported hematozoa lineages detected in waterfowl (Haemoproteus and Leucocytozoon) or other avian taxa (Plasmodium) providing support for lack of host specificity for some parasite lineages.
Radin, Joanna
2014-09-01
In the decades after World War II, the World Health Organization (WHO) played an important role in managing the process of stabilizing collections of variable blood samples as a fundamentally unstable, protean, and unfolding biomedical resource. In this system, known and as yet unknown constituents of blood were positioned as relevant to the work of multiple constituencies including human population geneticists, physical anthropologists, and immunologists. To facilitate serving these and other constituencies, it was crucial to standardize practices of collecting and preserving samples of blood from globally distributed human populations. The WHO achieved this by linking its administrative infrastructure-comprised of expert advisory groups and technical reports-to key laboratories, which served as sites for demonstrating and also for disseminating standards for working with variable blood samples. The practices that were articulated in making blood samples into a flexible resource contributes to emerging histories of global health that highlight the centrality of new institutions, like the WHO, new forms of expertise, like population genetics and serological epidemiology, and new kinds of research materials, like frozen blood. Copyright © 2014 Elsevier Ltd. All rights reserved.
Tissue, Blood, and Body Fluid Sample Collection From Patients With Hematologic Cancer
2017-09-20
Chronic Myeloproliferative Disorders; Leukemia; Lymphoma; Lymphoproliferative Disorder; Multiple Myeloma and Plasma Cell Neoplasm; Myelodysplastic Syndromes; Myelodysplastic/Myeloproliferative Neoplasms; Nonmalignant Neoplasm
Red Cell Properties after Different Modes of Blood Transportation
Makhro, Asya; Huisjes, Rick; Verhagen, Liesbeth P.; Mañú-Pereira, María del Mar; Llaudet-Planas, Esther; Petkova-Kirova, Polina; Wang, Jue; Eichler, Hermann; Bogdanova, Anna; van Wijk, Richard; Vives-Corrons, Joan-Lluís; Kaestner, Lars
2016-01-01
Transportation of blood samples is unavoidable for assessment of specific parameters in blood of patients with rare anemias, blood doping testing, or for research purposes. Despite the awareness that shipment may substantially alter multiple parameters, no study of that extent has been performed to assess these changes and optimize shipment conditions to reduce transportation-related artifacts. Here we investigate the changes in multiple parameters in blood of healthy donors over 72 h of simulated shipment conditions. Three different anticoagulants (K3EDTA, Sodium Heparin, and citrate-based CPDA) for two temperatures (4°C and room temperature) were tested to define the optimal transportation conditions. Parameters measured cover common cytology and biochemistry parameters (complete blood count, hematocrit, morphological examination), red blood cell (RBC) volume, ion content and density, membrane properties and stability (hemolysis, osmotic fragility, membrane heat stability, patch-clamp investigations, and formation of micro vesicles), Ca2+ handling, RBC metabolism, activity of numerous enzymes, and O2 transport capacity. Our findings indicate that individual sets of parameters may require different shipment settings (anticoagulants, temperature). Most of the parameters except for ion (Na+, K+, Ca2+) handling and, possibly, reticulocytes counts, tend to favor transportation at 4°C. Whereas plasma and intraerythrocytic Ca2+ cannot be accurately measured in the presence of chelators such as citrate and EDTA, the majority of Ca2+-dependent parameters are stabilized in CPDA samples. Even in blood samples from healthy donors transported using an optimized shipment protocol, the majority of parameters were stable within 24 h, a condition that may not hold for the samples of patients with rare anemias. This implies for as short as possible shipping using fast courier services to the closest expert laboratory at reach. Mobile laboratories or the travel of the patients to the specialized laboratories may be the only option for some groups of patients with highly unstable RBCs. PMID:27471472
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moen, Scott T.; Hatcher, Christopher L.; Singh, Anup K.
We present a miniaturized centrifugal platform that uses density centrifugation for separation and analysis of biological components in small volume samples (~5 μL). We demonstrate the ability to enrich leukocytes for on-disk visualization via microscopy, as well as recovery of viable cells from each of the gradient partitions. In addition, we simplified the traditional Modified Wright-Giemsa staining by decreasing the time, volume, and expertise involved in the procedure. From a whole blood sample, we were able to extract 95.15% of leukocytes while excluding 99.8% of red blood cells. Furthermore, this platform has great potential in both medical diagnostics and researchmore » applications as it offers a simpler, automated, and inexpensive method for biological sample separation, analysis, and downstream culturing.« less
Moen, Scott T.; Hatcher, Christopher L.; Singh, Anup K.
2016-04-07
We present a miniaturized centrifugal platform that uses density centrifugation for separation and analysis of biological components in small volume samples (~5 μL). We demonstrate the ability to enrich leukocytes for on-disk visualization via microscopy, as well as recovery of viable cells from each of the gradient partitions. In addition, we simplified the traditional Modified Wright-Giemsa staining by decreasing the time, volume, and expertise involved in the procedure. From a whole blood sample, we were able to extract 95.15% of leukocytes while excluding 99.8% of red blood cells. Furthermore, this platform has great potential in both medical diagnostics and researchmore » applications as it offers a simpler, automated, and inexpensive method for biological sample separation, analysis, and downstream culturing.« less
NASA Astrophysics Data System (ADS)
Suzuki, Yusuke; Maruo, Katsuhiko; Zhang, Alice W.; Shimogaki, Kazushige; Ogawa, Hideto; Hirayama, Fumiya
2012-01-01
Bacterial contamination of blood products is one of the most frequent infectious complications of transfusion. Since glucose levels in blood supplies decrease as bacteria proliferate, it should be possible to detect the presence of bacterial contamination by measuring the glucose concentrations in the blood components. Hence this study is aimed to serve as a preliminary study for the nondestructive measurement of glucose level in transfusion blood. The glucose concentrations in red blood cell (RBC) samples were predicted using near-infrared diffuse-reflectance spectroscopy in the 1350 to 1850 nm wavelength region. Furthermore, the effects of donor, hematocrit level, and temperature variations among the RBC samples were observed. Results showed that the prediction performance of a dataset which contained samples that differed in all three parameters had a standard error of 29.3 mg/dL. Multiplicative scatter correction (MSC) preprocessing method was also found to be effective in minimizing the variations in scattering patterns created by various sample properties. The results suggest that the diffuse-reflectance spectroscopy may provide another avenue for the detection of bacterial contamination in red cell concentrations (RCC) products.
Morin, Alexander M; Gatev, Evan; McEwen, Lisa M; MacIsaac, Julia L; Lin, David T S; Koen, Nastassja; Czamara, Darina; Räikkönen, Katri; Zar, Heather J; Koenen, Karestan; Stein, Dan J; Kobor, Michael S; Jones, Meaghan J
2017-01-01
Cord blood is a commonly used tissue in environmental, genetic, and epigenetic population studies due to its ready availability and potential to inform on a sensitive period of human development. However, the introduction of maternal blood during labor or cross-contamination during sample collection may complicate downstream analyses. After discovering maternal contamination of cord blood in a cohort study of 150 neonates using Illumina 450K DNA methylation (DNAm) data, we used a combination of linear regression and random forest machine learning to create a DNAm-based screening method. We identified a panel of DNAm sites that could discriminate between contaminated and non-contaminated samples, then designed pyrosequencing assays to pre-screen DNA prior to being assayed on an array. Maternal contamination of cord blood was initially identified by unusual X chromosome DNA methylation patterns in 17 males. We utilized our DNAm panel to detect contaminated male samples and a proportional amount of female samples in the same cohort. We validated our DNAm screening method on an additional 189 sample cohort using both pyrosequencing and DNAm arrays, as well as 9 publically available cord blood 450K data sets. The rate of contamination varied from 0 to 10% within these studies, likely related to collection specific methods. Maternal blood can contaminate cord blood during sample collection at appreciable levels across multiple studies. We have identified a panel of markers that can be used to identify this contamination, either post hoc after DNAm arrays have been completed, or in advance using a targeted technique like pyrosequencing.
Li, Han-Qing; Mei, Jian-Gang; Cao, Hong-Qin; Shao, Liang-Jing; Zhai, Yong-Ping
2017-12-01
To establish a multiple myeloma specimen bank applied for molecular biological researches and to explore the methods of specimen collection, transportation, storage, quality control and the management of specimen bank. Bone marrow and blood samples were collected from multiple myeloma patients, plasma cell sorting were operated after the separation of mononuclear cells from bone marrow specimens. The plasma cells were divided into 2 parts, one was added with proper amount of TRIzol and then kept in -80 °C refrigerator for subsequent RNA extraction, the other was added with proper amount of calf serum cell frozen liquid and then kept in -80 °C refrigerator for subsequent cryopreservation of DNA extraction after numbered respectively. Serum and plasma were separated from peripheral blood, specimens of serum and plasma were then stored at -80 °C refrigerator after registration. Meantime, the myeloma specimen information management system was established, managed and maintained by specially-assigned persons and continuous modification and improvement in the process of use as to facilitate the rapid collection, management, query of the effective samples and clinical data. A total of 244 portions plasma cells, 564 portions of serum, and 1005 portions of plasma were collected, clinical characters were documented. A multiple myeloma specimen bank have been established initially, which can provide quality samples and related clinical information for molecular biological research on multiple myeloma.
Wei, Yongyue; Shi, Qianwen; Wang, Zhaoxi; Zhang, Ruyang; Su, Li; Quamruzzaman, Quazi; Rahman, Mahmuder; Chen, Feng; Christiani, David C
2017-05-01
Arsenic exposure has been associated with low birth weight. However, the underlying mechanisms are not well understood. Alterations to metabolites may act as causal mediators of the effect of arsenic exposure on low birth weight. This pilot study aimed to explore the role of metabolites in mediating the association of arsenic exposure on infant birth weight. Study samples were selected from a well-established prospectively enrolled cohort in Bangladesh comprising 35 newborns and a subset of 20 matched mothers. Metabolomics profiling was performed on 35 cord blood samples and 20 maternal peripheral blood samples collected during the second trimester of pregnancy. Inorganic arsenic (iAs) exposure was evaluated via cord blood samples and maternal toenail samples collected during the first trimester. Multiple linear regression and mediation analyses were used to explore the relationship between iAs exposure, metabolite alterations, and low birth weight. Cord blood arsenic level was correlated with elevated levels of 17-methylstearate, laurate (12:0) and 4-vinylphenol sulfate along with lower birth weight. Prenatal maternal toenail iAs level was associated with two peripheral blood metabolites (butyrylqlycine and tartarate), which likely contributed to higher cord blood iAs levels both independently and interactively. Findings of this pilot study indicate that both intrauterine and maternal peripheral blood metabolites appear to influence the toxic effect of inorganic arsenic exposure on low birth weight.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Yangho; Lee, Byung-Kook, E-mail: bklee@sch.ac.kr
Introduction: The objective of this study was to evaluate associations between blood lead, cadmium, and mercury levels with estimated glomerular filtration rate in a general population of South Korean adults. Methods: This was a cross-sectional study based on data obtained in the Korean National Health and Nutrition Examination Survey (KNHANES) (2008-2010). The final analytical sample consisted of 5924 participants. Estimated glomerular filtration rate (eGFR) was calculated using the MDRD Study equation as an indicator of glomerular function. Results: In multiple linear regression analysis of log2-transformed blood lead as a continuous variable on eGFR, after adjusting for covariates including cadmium andmore » mercury, the difference in eGFR levels associated with doubling of blood lead were -2.624 mL/min per 1.73 m Superscript-Two (95% CI: -3.803 to -1.445). In multiple linear regression analysis using quartiles of blood lead as the independent variable, the difference in eGFR levels comparing participants in the highest versus the lowest quartiles of blood lead was -3.835 mL/min per 1.73 m Superscript-Two (95% CI: -5.730 to -1.939). In a multiple linear regression analysis using blood cadmium and mercury, as continuous or categorical variables, as independent variables, neither metal was a significant predictor of eGFR. Odds ratios (ORs) and 95% CI values for reduced eGFR calculated for log2-transformed blood metals and quartiles of the three metals showed similar trends after adjustment for covariates. Discussion: In this large, representative sample of South Korean adults, elevated blood lead level was consistently associated with lower eGFR levels and with the prevalence of reduced eGFR even in blood lead levels below 10 {mu}g/dL. In conclusion, elevated blood lead level was associated with lower eGFR in a Korean general population, supporting the role of lead as a risk factor for chronic kidney disease.« less
Assessing human metal accumulations in an urban superfund site.
Hailer, M Katie; Peck, Christopher P; Calhoun, Michael W; West, Robert F; James, Kyle J; Siciliano, Steven D
2017-09-01
Butte, Montana is part of the largest superfund site in the continental United States. Open-pit mining continues in close proximity to Butte's urban population. This study seeks to establish baseline metal concentrations in the hair and blood of individuals living in Butte, MT and possible routes of exposure. Volunteers from Butte (n=116) and Bozeman (n=86) were recruited to submit hair and blood samples and asked to complete a lifestyle survey. Elemental analysis of hair and blood samples was performed by ICP-MS. Three air monitors were stationed in Butte to collect particulate and filters were analyzed by ICP-MS. Soil samples from the yards of Butte volunteers were quantified by ICP-MS. Hair analysis revealed concentrations of Al, As, Cd, Cu, Mn, Mo, and U to be statistically elevated in Butte's population. Blood analysis revealed that the concentration of As was also statistically elevated in the Butte population. Multiple regression analysis was performed for the elements As, Cu, and Mn for hair and blood samples. Soil samples revealed detectable levels of As, Pb, Cu, Mn, and Cd, with As and Cu levels being higher than expected in some of the samples. Air sampling revealed consistently elevated As and Mn levels in the larger particulate sampled as compared to average U.S. ambient air data. Copyright © 2017 Elsevier B.V. All rights reserved.
Casale, Teodorico; Sacco, Carmina; Ricci, Serafino; Loreti, Beatrice; Pacchiarotti, Alessandro; Cupelli, Vincenzo; Arcangeli, Giulio; Mucci, Nicola; Antuono, Vittorio; De Marco, Federica; Tomei, Gianfranco; Tomei, Francesco; Rosati, Maria Valeria
2016-06-01
Few studies in the literature have examined the effects of benzene on blood cells. The aim of this study was to evaluate the possible correlation between the blood benzene levels and the blood cell counts. From a population of 2658 workers, we studied a group of 215 subjects. Each worker underwent blood sampling for the assessment of the blood benzene levels and the blood cell counts. The Mann-Whitney U test for two-mode variables and the Kruskal-Wallis test for more-than-two-mode variables were performed on all subjects. We estimated the Pearson correlation index between the variables in the total sample and the subgroups divided according to sex, the smoking habit, and job. After the main confounding factors were evaluated, multiple linear regression was performed on both the total sample and the subgroups. A significant inverse correlation was found among the blood benzene levels and the white blood cells, lymphocytes, and neutrophils in traffic policemen, motorcyclists, and other outdoor workers. We did not find any significant correlation with any other parameters of blood cell count. Our results, which must be considered preliminary, indicate that increased blood benzene levels in outdoor workers lead to decreased counts of white blood cells, neutrophils, and lymphocytes, because of possible immune effects. These are worth investigating in the future by specific immune tests. Copyright © 2016. Published by Elsevier Ltd.
Cao, Xia; Xie, Xiumei; Xu, Guo; Yuan, Hong; Chen, Zhiheng
2014-06-01
To investigate the relationship between high-normal blood pressure and chronic kidney disease (CKD) in occupational physical examination population in Changsha. With a convenient sampling method, a cross-sectional survey of representative sample of 11 274 white collar workers was conducted in Changsha between March 2011 and May 2011 in a large comprehensive hospital. All subjects were assigned into 4 groups: a normal blood pressure group, a high-normal blood pressure group, an undiagnosed hypertension group, and a diagnosed hypertension group. Anthropometry, blood pressure, blood sample and urine sample were measured with standard instruments and methodology for all the subjects. Multiple logistic regression analysis was used to identify risk factors for CKD. The prevalence of CKD in the normal blood pressure, high-normal blood pressure, undiagnosed hypertension, and diagnosed hypertension were 3.31%, 6.60%, 11.78%, and 17.35%, respectively. The prevalence of CKD in males was significantly higher than that in females (P<0.01). For males with high-normal blood pressure, the CKD risk was significantly greater (OR, 1.30; 95% CI:1.03 - 1.63) than those with optimal blood pressure. The logistic regression analysis showed that there was an additive effect of hyperuricemia on CKD risk in men with high-normal blood pressure compared with men with optimal blood pressure (OR, 2.25; 95% CI, 1.59 - 3.19; P<0.05). The prevalence of CKD in people with the high-normal blood pressure is 6.60% in occupational physical examination population in Changsha. CKD is a high risk for men with highnormal blood pressure and hyperuricemia is an independent risk factor.
Automated blood-sample handling in the clinical laboratory.
Godolphin, W; Bodtker, K; Uyeno, D; Goh, L O
1990-09-01
The only significant advances in blood-taking in 25 years have been the disposable needle and evacuated blood-drawing tube. With the exception of a few isolated barcode experiments, most sample-tracking is performed through handwritten or computer-printed labels. Attempts to reduce the hazards of centrifugation have resulted in air-tight lids or chambers, the use of which is time-consuming and cumbersome. Most commonly used clinical analyzers require serum or plasma, distributed into specialized containers, unique to that analyzer. Aliquots for different tests are prepared by handpouring or pipetting. Moderate to large clinical laboratories perform so many different tests that even multi-analyzers performing multiple analyses on a single sample may account for only a portion of all tests ordered for a patient. Thus several aliquots of each specimen are usually required. We have developed a proprietary serial centrifuge and blood-collection tube suitable for incorporation into an automated or robotic sample-handling system. The system we propose is (a) safe--avoids or prevents biological danger to the many "handlers" of blood; (b) small--minimizes the amount of sample taken and space required to adapt to the needs of satellite and mobile testing, and direct interfacing with analyzers; (c) serial--permits each sample to be treated according to its own "merits," optimizes throughput, and facilitates flexible automation; and (d) smart--ensures quality results through monitoring and intelligent control of patient identification, sample characteristics, and separation process.
Springer, Jan; White, P Lewis; Hamilton, Shanna; Michel, Denise; Barnes, Rosemary A; Einsele, Hermann; Löffler, Juergen
2016-03-01
Standardized methodologies for the molecular detection of invasive aspergillosis (IA) have been established by the European Aspergillus PCR Initiative for the testing of whole blood, serum, and plasma. While some comparison of the performance of Aspergillus PCR when testing these different sample types has been performed, no single study has evaluated all three using the recommended protocols. Standardized Aspergillus PCR was performed on 423 whole-blood pellets (WBP), 583 plasma samples, and 419 serum samples obtained from hematology patients according to the recommendations. This analysis formed a bicenter retrospective anonymous case-control study, with diagnosis according to the revised European Organization for Research and Treatment of Cancer/Invasive Fungal Infections Cooperative Group and National Institute of Allergy and Infectious Diseases Mycoses Study Group (EORTC/MSG) consensus definitions (11 probable cases and 36 controls). Values for clinical performance using individual and combined samples were calculated. For all samples, PCR positivity was significantly associated with cases of IA (for plasma, P = 0.0019; for serum, P = 0.0049; and for WBP, P = 0.0089). Plasma PCR generated the highest sensitivity (91%); the sensitivities for serum and WBP PCR were 80% and 55%, respectively. The highest specificity was achieved when testing WBP (96%), which was significantly superior to the specificities achieved when testing serum (69%, P = 0.0238) and plasma (53%, P = 0.0002). No cases were PCR negative in all specimen types, and no controls were PCR positive in all specimens. This study confirms that Aspergillus PCR testing of plasma provides robust performance while utilizing commercial automated DNA extraction processes. Combining PCR testing of different blood fractions allows IA to be both confidently diagnosed and excluded. A requirement for multiple PCR-positive plasma samples provides similar diagnostic utility and is technically less demanding. Time to diagnosis may be enhanced by testing multiple contemporaneously obtained sample types. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Sutton, N; Tracey, M C; Johnston, I D; Greenaway, R S; Rampling, M W
1997-05-01
A novel instrument has been developed to study the microrheology of erythrocytes as they flow through channels of dimensions similar to human blood capillaries. The channels are produced in silicon substrates using microengineering technology. Accurately defined, physiological driving pressures and temperatures are employed whilst precise, real-time image processing allows individual cells to be monitored continuously during their transit. The instrument characterises each cell in a sample of ca. 1000 in terms of its volume and flow velocity profile during its transit through a channel. The unique representation of the data in volume/velocity space provides new insight into the microrheological behaviour of blood. The image processing and subsequent data analysis enable the system to reject anomalous events such as multiple cell transits, thereby ensuring integrity of the resulting data. By employing an array of microfluidic flow channels we can integrate a number of different but precise and highly reproducible channel sizes and geometries within one array, thereby allowing multiple, concurrent isobaric measurements on one sample. As an illustration of the performance of the system, volume/velocity data sets recorded in a microfluidic device incorporating multiple channels of 100 microns length and individual widths ranging between 3.0 and 4.0 microns are presented.
Mellert, Hestia S.; Alexander, Kristin E.; Jackson, Leisa P.; Pestano, Gary A.
2018-01-01
We have developed novel methods for the isolation and characterization of tumor-derived circulating ribonucleic acid (cRNA) for blood-based liquid biopsy. Robust detection of cRNA recovered from blood represents a solution to a critical unmet need in clinical diagnostics. The test begins with the collection of whole blood into blood collection tubes containing preservatives that stabilize cRNA. Cell-free, exosomal, and platelet-associated RNA is isolated from plasma in this test system. The cRNA is reverse transcribed to complementary DNA (cDNA) and amplified using digital polymerase chain reaction (dPCR). Samples are evaluated for both the target biomarker as well as a control gene. Test validation included limit of detection, accuracy, and robustness studies with analytic samples. The method developed as a result of these studies reproducibly detect multiple fusion variants for ROS1 (C-Ros proto-oncogene 1; 8 variants) and RET (rearranged during transfection proto-oncogene; 8 variants). The sample processing workflow has been optimized so that test results can consistently be generated within 72 hours of sample receipt. PMID:29683453
Multiple Reaction Monitoring Enables Precise Quantification of 97 Proteins in Dried Blood Spots*
Chambers, Andrew G.; Percy, Andrew J.; Yang, Juncong; Borchers, Christoph H.
2015-01-01
The dried blood spot (DBS) methodology provides a minimally invasive approach to sample collection and enables room-temperature storage for most analytes. DBS samples have successfully been analyzed by liquid chromatography multiple reaction monitoring mass spectrometry (LC/MRM-MS) to quantify a large range of small molecule biomarkers and drugs; however, this strategy has only recently been explored for MS-based proteomics applications. Here we report the development of a highly multiplexed MRM assay to quantify endogenous proteins in human DBS samples. This assay uses matching stable isotope-labeled standard peptides for precise, relative quantification, and standard curves to characterize the analytical performance. A total of 169 peptides, corresponding to 97 proteins, were quantified in the final assay with an average linear dynamic range of 207-fold and an average R2 value of 0.987. The total range of this assay spanned almost 5 orders of magnitude from serum albumin (P02768) at 18.0 mg/ml down to cholinesterase (P06276) at 190 ng/ml. The average intra-assay and inter-assay precision for 6 biological samples ranged from 6.1–7.5% CV and 9.5–11.0% CV, respectively. The majority of peptide targets were stable after 154 days at storage temperatures from −20 °C to 37 °C. Furthermore, protein concentration ratios between matching DBS and whole blood samples were largely constant (<20% CV) across six biological samples. This assay represents the highest multiplexing yet achieved for targeted protein quantification in DBS samples and is suitable for biomedical research applications. PMID:26342038
McCoy, Alene T; Bartels, Michael J; Rick, David L; Saghir, Shakil A
2012-07-01
TK Modeler 1.0 is a Microsoft® Excel®-based pharmacokinetic (PK) modeling program created to aid in the design of toxicokinetic (TK) studies. TK Modeler 1.0 predicts the diurnal blood/plasma concentrations of a test material after single, multiple bolus or dietary dosing using known PK information. Fluctuations in blood/plasma concentrations based on test material kinetics are calculated using one- or two-compartment PK model equations and the principle of superposition. This information can be utilized for the determination of appropriate dosing regimens based on reaching a specific desired C(max), maintaining steady-state blood/plasma concentrations, or other exposure target. This program can also aid in the selection of sampling times for accurate calculation of AUC(24h) (diurnal area under the blood concentration time curve) using sparse-sampling methodologies (one, two or three samples). This paper describes the construction, use and validation of TK Modeler. TK Modeler accurately predicted blood/plasma concentrations of test materials and provided optimal sampling times for the calculation of AUC(24h) with improved accuracy using sparse-sampling methods. TK Modeler is therefore a validated, unique and simple modeling program that can aid in the design of toxicokinetic studies. Copyright © 2012 Elsevier Inc. All rights reserved.
Automated Microorganism Detector
NASA Astrophysics Data System (ADS)
Keahey, Pelham; Hardy, Will; Cradit, Mason; Solis, Steven; Holland, Andrea; Wade, Gerry
2010-10-01
The detection and identification of bacteria in blood samples is crucial for treating patients suspected of having a blood infection. Current hospital methods for pathogen detection are time-consuming processes with multiple steps. This project's goal was to develop an efficient biomedical device to detect bacterial growth in blood samples, based on Gerald J. Wade's 1979 invention (US patents 4250266 and 4267276). Detection was accomplished using a system of electronics to examine the change in the electrochemical properties of a sample in response to bacterial growth, by measuring the sample's electrical charging and charge dispersion characteristics. After initial trials, it was found that a sample yielded consistent voltage measurements of approximately 200 millivolts prior to any detectable microbial growth. The first species tested, Escherichia coli (E. coli), was detected 11.7 hours after its inoculation in a culture bottle at a concentration of approximately 5-10 organisms per milliliter. In future tests, it is expected that detection times will vary in proportion to the growth rate of each species.
[Transfusion supply optimization in multiple-discipline surgical hospital].
Solov'eva, I N; Trekova, N A; Krapivkin, I A
2016-01-01
To define optimal variant of transfusion supply of hospital by blood components and to decrease donor blood expense via application of blood preserving technologies. Donor blood components expense, volume of hemotransfusions and their proportion for the period 2012-2014 were analyzed. Number of recipients of packed red cells, fresh-frozen plasma and packed platelets reduced 18.5%, 25% and 80% respectively. Need for donor plasma decreased 35%. Expense of autologous plasma in cardiac surgery was 76% of overall volume. Preoperative plasma sampling is introduced in patients with aortic aneurysm. Number of cardiac interventions performed without donor blood is increased 7-31% depending on its complexity.
Nickel and blood counts in workers exposed to urban stressors.
Rosati, Maria Valeria; Casale, Teodorico; Ciarrocca, Manuela; Weiderpass, Elisabete; Capozzella, Assunta; Schifano, Maria Pia; Tomei, Francesco; Nieto, Hector Alberto; Marrocco, Mariasilvia; Tomei, Gianfranco; Caciari, Tiziana; Sancini, Angela
2016-06-01
Nickel (Ni) and Ni compounds are widely present in the urban air. The purpose of this study is to estimate exposure of individuals to Ni and the correlation between this exposure and the values of blood counts in outdoor workers. This study focused on a sample of 101 outdoor workers (55 male and 46 female; 65 nonsmokers and 36 smokers), all employed in the municipal police in a large Italian city. The personal levels of exposure to Ni were assessed through (a) environmental monitoring of Ni present in the urban air obtained from individual samples and (b) biological monitoring of urinary and blood Ni. The blood count parameters were obtained from the hemochromocytometric tests. Pearson correlation coefficients (r) were calculated to assess the association between the blood and urinary Ni and the complete blood count. Multiple linear regression models were used to examine the associations between the complete blood count and the independent variables (age, gender, years of work for current tasks, cigarette smoking habit (current and never smoker), values of airborne Ni, and blood and urinary Ni). Multiple linear regression analysis performed on the total group of 101 subjects confirms the association among the red blood cells count, the hematocrit, and the urinary Ni (R(2) = 0.520, p = 0.025 and R(2) = 0.530, p = 0.030). These results should lead to further studies on the effects of Ni in working populations exposed to urban pollutants. The possibility that the associations found in our study may be partially explained by other urban pollutants (such as benzene, toluene, and other heavy metals) not taken into consideration in this study cannot be ruled out. © The Author(s) 2014.
Imaging System and Method for Biomedical Analysis
2013-03-11
biological particles and items of interest. Broadly, Padmanabhan et al. utilize the diffraction of a laser light source in flow cytometry to count...spread of light from multiple LED devices over the entire sample surface. Preferably, light source 308 projects a full spectrum white light. Light...for example, red blood cells, white blood cells (which may include lymphocytes which are relatively large and easily detectable), T-helper cells
Pomelova, V G; Osin, N S
2007-01-01
This literature review is dedicated to prospects of the use of whole blood dried on special filter paper as a source of biological material for human health and environmental population studies. Evident advantages of this low-invasive approach include the following: it is easy to take a blood sample from a patient's finger ofa neonate's heel; the cost of sampling as well as transportation and storage of samples is low; paper blanks are safe to manipulate with and convenient to mail in sealed plastic packages. Many analytes, such as DNA, become more stable after drying, which allows for the detection of phenotypic and genotypic markers, as well as multiple gene mutations by multiplex DNA amplification. Modern diagnostic techniques make it possible to detect a wide spectrum of biomarkers characterizing the condition of the endocrine, cardiovascular, reproductive, and immune systems of the organism in a single drop of blood. This allows considering paper blanks with dry blood the key component of multilevel interdisciplinary population studies on neonatal screening, disease spread surveillance, seroepidemiological monitoring, and ecological and genetic research.
Blood Samples From Patients on a Clinical Trial to CINV During HSCT
2017-05-07
Breast Cancer; Chronic Myeloproliferative Disorders; Gestational Trophoblastic Tumor; Leukemia; Lymphoma; Multiple Myeloma and Plasma Cell Neoplasm; Myelodysplastic Syndromes; Myelodysplastic/Myeloproliferative Neoplasms; Nausea and Vomiting; Neuroblastoma; Ovarian Cancer; Testicular Germ Cell Tumor
Kordas, Katarzyna; Ardoino, Graciela; Coffman, Donna L.; Queirolo, Elena I.; Ciccariello, Daniela; Mañay, Nelly; Ettinger, Adrienne S.
2015-01-01
While it is known that toxic metals contribute individually to child cognitive and behavioral deficits, we still know little about the effects of exposure to multiple metals, particularly when exposures are low. We studied the association between children's blood lead and hair arsenic, cadmium, and manganese and their performance on the Bayley Scales of Infant Development III. Ninety-two preschool children (age 13–42 months) from Montevideo, Uruguay, provided a hair sample and 78 had a blood lead level (BLL) measurement. Using latent class analysis (LCA), we identified four groups of exposure based on metal concentrations: (1) low metals, (2) low-to-moderate metals, (3) high lead and cadmium, and (4) high metals. Using the four-group exposure variable as the main predictor, and fitting raw scores on the cognitive, receptive vocabulary, and expressive vocabulary scales as dependent variables, both complete-case and multiple imputation (MI) analyses were conducted. We found no association between multiple-metal exposures and neurodevelopment in covariate-adjusted models. This study demonstrates the use of LCA together with MI to determine patterns of exposure to multiple toxic metals and relate these to child neurodevelopment. However, because the overall study population was small, other studies with larger sample sizes are needed to investigate these associations. PMID:25694786
Peterson, Sarah H.; McHuron, Elizabeth A.; Kennedy, Stephanie N.; Ackerman, Joshua T.; Rea, Lorrie D.; Castellini, J. Margaret; O'Hara, Todd M.; Costa, Daniel P.
2016-01-01
Mercury (Hg) biomonitoring of pinnipeds increasingly utilizes nonlethally collected tissues such as hair and blood. The relationship between total Hg concentrations ([THg]) in these tissues is not well understood for marine mammals, but it can be important for interpretation of tissue concentrations with respect to ecotoxicology and biomonitoring. We examined [THg] in blood and hair in multiple age classes of four pinniped species. For each species, we used paired blood and hair samples to quantify the ability of [THg] in hair to predict [THg] in blood at the time of sampling and examined the influence of varying ontogenetic phases and life history of the sampled animals. Overall, we found that the relationship between [THg] in hair and blood was affected by factors including age class, weaning status, growth, and the time difference between hair growth and sample collection. Hair [THg] was moderately to strongly predictive of current blood [THg] for adult female Steller sea lions (Eumetopias jubatus), adult female California sea lions (Zalophus californianus), and adult harbor seals (Phoca vitulina), whereas hair [THg] was poorly predictive or not predictive (different times of year) of blood [THg] for adult northern elephant seals (Mirounga angustirostris). Within species, except for very young pups, hair [THg] was a weaker predictor of blood [THg] for prereproductive animals than for adults likely due to growth, variability in foraging behavior, and transitions between ontogenetic phases. Our results indicate that the relationship between hair [THg] and blood [THg] in pinnipeds is variable and that ontogenetic phase and life history should be considered when interpreting [THg] in these tissues.
Li, Heming; Meng, Qing H; Noh, Hyangsoon; Batth, Izhar Singh; Somaiah, Neeta; Torres, Keila E; Xia, Xueqing; Wang, Ruoyu; Li, Shulin
2017-09-10
Circulating tumor cells (CTCs) enter the vasculature or lymphatic system after shedding from the primary tumor. CTCs may serve as "seed" cells for tumor metastasis. The utility of CTCs in clinical applications for sarcoma is not fully investigated, partly owing to the necessity for fresh blood samples and the lack of a CTC-specific antibody. To overcome these drawbacks, we developed a technique for sarcoma CTCs capture and detection using cryopreserved peripheral blood mononuclear cells (PBMCs) and our proprietary cell-surface vimentin (CSV) antibody 84-1, which is specific to tumor cells. This technique was validated by sarcoma cell spiking assay, matched CTCs comparison between fresh and cryopreserved PBMCs, and independent tumor markers in multiple types of sarcoma patient blood samples. The reproducibility was maximized when cryopreserved PBMCs were prepared from fresh blood samples within 2 h of the blood draw. In summary, as far as we are aware, ours is the first report to capture and detect CTCs from cryopreserved PBMCs. Further validation in other types of tumor may help boost the feasibility and utility of CTC-based diagnosis in a centralized laboratory. Copyright © 2017 Elsevier B.V. All rights reserved.
Meyer, Golo M; Maurer, Hans H; Meyer, Markus R
2016-01-01
This paper reviews MS approaches applied to metabolism studies, structure elucidation and qualitative or quantitative screening of drugs (of abuse) and/or their metabolites. Applications in clinical and forensic toxicology were included using blood plasma or serum, urine, in vitro samples, liquids, solids or plant material. Techniques covered are liquid chromatography coupled to low-resolution and high-resolution multiple stage mass analyzers. Only PubMed listed studies published in English between January 2008 and January 2015 were considered. Approaches are discussed focusing on sample preparation and mass spectral settings. Comments on advantages and limitations of these techniques complete the review.
Carfora, Anna; Campobasso, Carlo Pietro; Cassandro, Paola; Petrella, Raffaella; Borriello, Renata
2018-05-09
A recent update of the Italian Road Traffic Law (RTL 41/2016), established severe penal sanctions when drivers, driving under the influence of alcohol (DUI) or drugs (DUID), are involved in road accident that results in death or injuries. A study was carried out to assess the trends of consumption of alcohol, illicit drugs or pharmaceutical among injured drivers suspected for DUI or DUID from 2009 to 2016 in the region of Campania (Italy). Confirmation toxicological analyses were performed on 780 blood samples and 1017 urine samples collected from 1797 injured drivers. These drivers all tested positive for alcohol or drug use through immunoassay screening applied at hospital emergency units and their biological samples transferred to the Forensic Reference Laboratory (FRL) for confirmation analysis. The GC/HS-FID methodology was used to test Blood Alcohol Concentration (BAC). Qualitative and quantitative analyses for drugs were performed using the GC/MS or LC-MS/MS methodology. The BAC >0.5g/L was confirmed in 91.5% of drivers suspected for DUI cases and in 93% of DUID respectively. In DUI cases, results show an increasing incidence of road accidents involving drivers with BAC above 1.5g/L while at concentrations above 0.8g/L alcohol and drugs are both used. Among the suspected DUID cases, the intake of alcohol in association with drugs has consistently increased over time and positive results on blood samples was confirmed for multiple drugs (20%) or cannabis and cocaine alone (18%) followed by benzodiazepines (6%) and methadone (3.5%) respectively. The majority of injured drivers suspected for DUID (1017 cases) did not authorize blood sampling, therefore only urine was analyzed showing the prevalent use of cannabis, followed by multiple drug>cocaine>benzodiazepines>opiates. Among 1797 drivers, suspected at screening for DUI or DUID, 15.4% of cases (64 blood and 213 urine samples) were not confirmed by GC/HS, GC/MS or LC-MS/MS analysis. In forensic toxicological investigations, it is mandatory to satisfy the best quality standards, which is not achievable if immunochemical screening is only performed on urine. Therefore, only confirmed positive results of alcohol or drugs on blood samples can represent conclusive evidence to demonstrate the DUI or DUID related offences. An improvement of the protocols currently applied in Italy for the assessment of DUI or DUID crimes is needed and the confirmation analysis on blood should be considered mandatory. Copyright © 2018 Elsevier B.V. All rights reserved.
Freeman, Christine M; Crudgington, Sean; Stolberg, Valerie R; Brown, Jeanette P; Sonstein, Joanne; Alexis, Neil E; Doerschuk, Claire M; Basta, Patricia V; Carretta, Elizabeth E; Couper, David J; Hastie, Annette T; Kaner, Robert J; O'Neal, Wanda K; Paine, Robert; Rennard, Stephen I; Shimbo, Daichi; Woodruff, Prescott G; Zeidler, Michelle; Curtis, Jeffrey L
2015-01-27
Subpopulations and Intermediate Outcomes in COPD Study (SPIROMICS) is a multi-center longitudinal, observational study to identify novel phenotypes and biomarkers of chronic obstructive pulmonary disease (COPD). In a subset of 300 subjects enrolled at six clinical centers, we are performing flow cytometric analyses of leukocytes from induced sputum, bronchoalveolar lavage (BAL) and peripheral blood. To minimize several sources of variability, we use a "just-in-time" design that permits immediate staining without pre-fixation of samples, followed by centralized analysis on a single instrument. The Immunophenotyping Core prepares 12-color antibody panels, which are shipped to the six Clinical Centers shortly before study visits. Sputum induction occurs at least two weeks before a bronchoscopy visit, at which time peripheral blood and bronchoalveolar lavage are collected. Immunostaining is performed at each clinical site on the day that the samples are collected. Samples are fixed and express shipped to the Immunophenotyping Core for data acquisition on a single modified LSR II flow cytometer. Results are analyzed using FACS Diva and FloJo software and cross-checked by Core scientists who are blinded to subject data. Thus far, a total of 152 sputum samples and 117 samples of blood and BAL have been returned to the Immunophenotyping Core. Initial quality checks indicate useable data from 126 sputum samples (83%), 106 blood samples (91%) and 91 BAL samples (78%). In all three sample types, we are able to identify and characterize the activation state or subset of multiple leukocyte cell populations (including CD4+ and CD8+ T cells, B cells, monocytes, macrophages, neutrophils and eosinophils), thereby demonstrating the validity of the antibody panel. Our study design, which relies on bi-directional communication between clinical centers and the Core according to a pre-specified protocol, appears to reduce several sources of variability often seen in flow cytometric studies involving multiple clinical sites. Because leukocytes contribute to lung pathology in COPD, these analyses will help achieve SPIROMICS aims of identifying subgroups of patients with specific COPD phenotypes. Future analyses will correlate cell-surface markers on a given cell type with smoking history, spirometry, airway measurements, and other parameters. This study was registered with ClinicalTrials.gov as NCT01969344 .
Salim, Masome Afiati; Eftekharian, Mohammad Mahdi; Taheri, Mohammad; Yousef Alikhani, Mohammad
2017-07-19
Multiple sclerosis (MS) is a chronic autoimmune disease that disables central nervous system (CNS) system. Cytomegalovirus (CMV) probably has an important role in the MS pathology. The infection with helicobacter pylori also is recognized as a protective agent against MS in female. Serum samples were isolated and frozen at -70∘C. The earlier mentioned anti-virus antibodies and antibacterial antibodies were quantified by Elisa kit. The results showed that IgG antibody average value against cytomegalovirus in the blood of multiple sclerosis patients not only decreased but also was significant statistically (p< 0.05). IgM and IgG antibodies average value in the blood of multiple sclerosis patients against helicobacter pylori shown a statistically significant decrease (p< 0.05). Therefore it may be considered that probably helicobacter pylori presence in the individuals especially in female can alleviate MS signs. CMV infection can intensify the symptoms in multiple sclerosis patients.
MORRISON, LIAM J.; McCORMACK, GILLIAN; SWEENEY, LINDSAY; LIKEUFACK, ANNE C. L.; TRUC, PHILIPPE; TURNER, C. MICHAEL; TAIT, ANDY; MacLEOD, ANNETTE
2007-01-01
Whole genome amplification methods are a recently developed tool for amplifying DNA from limited template. We report its application in trypanosome infections, characterised by low parasitaemias. Multiple Displacement Amplification (MDA) amplifies DNA with a simple in vitro step, and was evaluated on mouse blood samples on FTA filter cards with known numbers of Trypanosoma brucei parasites. The data showed a twenty-fold increase in the number of PCRs possible per sample, using primers diagnostic for the multi-copy ribosomal ITS region or 177 bp repeats, and a twenty-fold increase in sensitivity over nested PCR against a single copy microsatellite. Using MDA for microsatellite genotyping caused allele dropout at low DNA concentrations, which was overcome by pooling multiple MDA reactions. The validity of using MDA was established with samples from Human African Trypanosomiasis patients. The use of MDA allows maximal use of finite DNA samples and may prove a valuable tool in studies where multiple reactions are necessary, such as population genetic analyses. PMID:17556624
Rezeli, Melinda; Végvári, Akos; Ottervald, Jan; Olsson, Tomas; Laurell, Thomas; Marko-Varga, György
2011-12-10
As a proof-of-principle study, a multiple reaction monitoring (MRM) assay was developed for quantitation of proteotypic peptides, representing seven plasma proteins associated with inflammation (complement components and C-reactive protein). The assay development and the sample analysis were performed on a linear ion trap mass spectrometer. We were able to quantify 5 of the 7 target proteins in depleted plasma digests with reasonable reproducibility over a 2 orders of magnitude linear range (RSD≤25%). The assay panel was utilized for the analysis of a small multiple sclerosis sample cohort with 10 diseased and 8 control patients. Copyright © 2011 Elsevier B.V. All rights reserved.
Lee, Hwan Young; Jung, Sang-Eun; Lee, Eun Hee; Yang, Woo Ick; Shin, Kyoung-Jin
2016-09-01
The ability to predict the type of tissues or cells from molecular profiles of crime scene samples has important practical implications in forensics. A previously reported multiplex assay using DNA methylation markers could only discriminate between 4 types of body fluids: blood, saliva, semen, and the body fluid which originates from female reproductive organ. In the present study, we selected 15 menstrual blood-specific CpG marker candidates based on analysis of 12 genome-wide DNA methylation profiles of vaginal fluid and menstrual blood. The menstrual blood-specificity of the candidate markers was confirmed by comparison with HumanMethylation450 BeadChip array data obtained for 58 samples including 12 blood, 12 saliva, 12 semen, 3 vaginal fluid, and 19 skin epidermis samples. Among 15CpG marker candidates, 3 were located in the promoter region of the SLC26A10 gene, and 2 of them (cg09696411 and cg18069290) showed high menstrual blood specificity. DNA methylation at the 2CpG markers was further tested by targeted bisulfite sequencing of 461 additional samples including 49 blood, 52 saliva, 34 semen, 125 vaginal fluid, and 201 menstrual blood. Because the 2 markers showed menstrual blood-specific methylation patterns, we modified our previous multiplex methylation SNaPshot reaction to include these 2 markers. In addition, a blood marker cg01543184 with cross reactivity to semen was replaced with cg08792630, and a semen-specific unmethylation marker cg17621389 was removed. The resultant multiplex methylation SNaPshot allowed positive identification of blood, saliva, semen, vaginal fluid and menstrual blood using the 9CpG markers which show a methylation signal only in the target body fluids. Because of the complexity in cell composition, menstrual bloods produced DNA methylation profiles that vary with menstrual cycle and sample collection methods, which are expected to provide more insight into forensic menstrual blood test. Moreover, because the developed multiplex methylation SNaPshot reaction includes the 4CpG markers of which specificities have been confirmed by multiple studies, it will facilitate confirmatory tests for body fluids that are frequently observed in forensic casework. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Optical coherence tomography for blood glucose monitoring through signal attenuation
NASA Astrophysics Data System (ADS)
De Pretto, Lucas R.; Yoshimura, Tania M.; Ribeiro, Martha S.; de Freitas, Anderson Z.
2016-03-01
Development of non-invasive techniques for glucose monitoring is crucial to improve glucose control and treatment adherence in patients with diabetes. Hereafter, Optical Coherence Tomography (OCT) may offer a good alternative for portable glucometers, since it uses light to probe samples. Changes in the object of interest can alter the intensity of light returning from the sample and, through it, one can estimate the sample's attenuation coefficient (μt) of light. In this work, we aimed to explore the behavior of μt of mouse's blood under increasing glucose concentrations. Different samples were prepared in four glucose concentrations using a mixture of heparinized blood, phosphate buffer saline and glucose. Blood glucose concentrations were measured with a blood glucometer, for reference. We have also prepared other samples diluting the blood in isotonic saline solution to check the effect of a higher multiple-scattering component on the ability of the technique to differentiate glucose levels based on μt. The OCT system used was a commercial Spectral Radar OCT with 930 nm central wavelength and spectral bandwidth (FWHM) of 100 nm. The system proved to be sensitive for all blood glucose concentrations tested, with good correlations with the obtained attenuation coefficients. A linear tendency was observed, with an increase in attenuation with higher values of glucose. Statistical difference was observed between all groups (p<0.001). This work opens the possibility towards a non-invasive diagnostic modality using OCT for glycemic control, which eliminates the use of analytes and/or test strips, as in the case with commercially available glucometers.
Detection of Merkel Cell Polyomavirus DNA in Serum Samples of Healthy Blood Donors
Mazzoni, Elisa; Rotondo, John C.; Marracino, Luisa; Selvatici, Rita; Bononi, Ilaria; Torreggiani, Elena; Touzé, Antoine; Martini, Fernanda; Tognon, Mauro G.
2017-01-01
Merkel cell polyomavirus (MCPyV) has been detected in 80% of Merkel cell carcinomas (MCC). In the host, the MCPyV reservoir remains elusive. MCPyV DNA sequences were revealed in blood donor buffy coats. In this study, MCPyV DNA sequences were investigated in the sera (n = 190) of healthy blood donors. Two MCPyV DNA sequences, coding for the viral oncoprotein large T antigen (LT), were investigated using polymerase chain reaction (PCR) methods and DNA sequencing. Circulating MCPyV sequences were detected in sera with a prevalence of 2.6% (5/190), at low-DNA viral load, which is in the range of 1–4 and 1–5 copies/μl by real-time PCR and droplet digital PCR, respectively. DNA sequencing carried out in the five MCPyV-positive samples indicated that the two MCPyV LT sequences which were analyzed belong to the MKL-1 strain. Circulating MCPyV LT sequences are present in blood donor sera. MCPyV-positive samples from blood donors could represent a potential vehicle for MCPyV infection in receivers, whereas an increase in viral load may occur with multiple blood transfusions. In certain patient conditions, such as immune-depression/suppression, additional disease or old age, transfusion of MCPyV-positive samples could be an additional risk factor for MCC onset. PMID:29238698
Collecting and Storing Blood Samples From Patients With Cancer
2011-12-08
Brain and Central Nervous System Tumors; Chronic Myeloproliferative Disorders; Leukemia; Lymphoma; Lymphoproliferative Disorder; Multiple Myeloma and Plasma Cell Neoplasm; Myelodysplastic Syndromes; Myelodysplastic/Myeloproliferative Neoplasms; Nonmalignant Neoplasm; Unspecified Adult Solid Tumor, Protocol Specific; Unspecified Childhood Solid Tumor, Protocol Specific
Sikirzhytskaya, Aliaksandra; Sikirzhytski, Vitali; McLaughlin, Gregory; Lednev, Igor K
2013-09-01
Body fluid traces recovered at crime scenes are among the most common and important types of forensic evidence. However, the ability to characterize a biological stain at a crime scene nondestructively has not yet been demonstrated. Here, we expand the Raman spectroscopic approach for the identification of dry traces of pure body fluids to address the problem of heterogeneous contamination, which can impair the performance of conventional methods. The concept of multidimensional Raman signatures was utilized for the identification of blood in dry traces contaminated with sand, dust, and soil. Multiple Raman spectra were acquired from the samples via automatic scanning, and the contribution of blood was evaluated through the fitting quality using spectroscopic signature components. The spatial mapping technique allowed for detection of "hot spots" dominated by blood contribution. The proposed method has great potential for blood identification in highly contaminated samples. © 2013 American Academy of Forensic Sciences.
Fan, Leimin; Lee, Jacob; Hall, Jeffrey; Tolentino, Edward J; Wu, Huaiqin; El-Shourbagy, Tawakol
2011-06-01
This article describes validation work for analysis of an Abbott investigational drug (Compound A) in monkey whole blood with dried blood spots (DBS). The impact of DBS spotting volume on analyte concentration was investigated. The quantitation range was between 30.5 and 10,200 ng/ml. Accuracy and precision of quality controls, linearity of calibration curves, matrix effect, selectivity, dilution, recovery and multiple stabilities were evaluated in the validation, and all demonstrated acceptable results. Incurred sample reanalysis was performed with 57 out of 58 samples having a percentage difference (versus the mean value) less than 20%. A linear relationship between the spotting volume and the spot area was drawn. The influence of spotting volume on concentration was discussed. All validation results met good laboratory practice acceptance requirements. Radial spreading of blood on DBS cards can be a factor in DBS concentrations at smaller spotting volumes.
Effects of psychological distress on blood pressure in adolescents.
Weinrich, S; Weinrich, M; Hardin, S; Gleaton, J; Pesut, D J; Garrison, C
2000-10-01
This cross-sectional survey measured relationships among blood pressure and measures of psychologic distress, family structure, and economic status in a sample of adolescents exposed to Hurricane Hugo. Spielberger's Anger Scale and Derogatis' Brief Symptom Inventory were used. Data analysis revealed 5% of the 1079 adolescents were hypertensive. Multiple regression analyses revealed the following predictors of higher diastolic blood pressure: African-American race, recipient of subsidized lunch, exposure to Hurricane Hugo, and higher anger-in scores in males. The effects of a catastrophic event such as a hurricane on blood pressure and the effects of introjected anger have implications for both health care consumers and providers.
NASA Astrophysics Data System (ADS)
De Pretto, Lucas Ramos; Yoshimura, Tania Mateus; Ribeiro, Martha Simões; Zanardi de Freitas, Anderson
2016-08-01
As diabetes causes millions of deaths worldwide every year, new methods for blood glucose monitoring are in demand. Noninvasive approaches may increase patient adherence to treatment while reducing costs, and optical coherence tomography (OCT) may be a feasible alternative to current invasive diagnostics. This study presents two methods for blood sugar monitoring with OCT in vitro. The first, based on spatial statistics, exploits changes in the light total attenuation coefficient caused by different concentrations of glucose in the sample using a 930-nm commercial OCT system. The second, based on temporal analysis, calculates differences in the decorrelation time of the speckle pattern in the OCT signal due to blood viscosity variations with the addition of glucose with data acquired by a custom built Swept Source 1325-nm OCT system. Samples consisted of heparinized mouse blood, phosphate buffer saline, and glucose. Additionally, further samples were prepared by diluting mouse blood with isotonic saline solution to verify the effect of higher multiple scattering components on the ability of the methods to differentiate glucose levels. Our results suggest a direct relationship between glucose concentration and both decorrelation rate and attenuation coefficient, with our systems being able to detect changes of 65 mg/dL in glucose concentration.
Yeo, Thong-Hiang; Ho, Mer-Lin; Loke, Weng-Keong
2008-01-01
A novel liquid chromatography-multiple reaction monitoring (LC-MRM) procedure has been developed for retrospective diagnosis of exposure to different forms of mustard agents. This concise method is able to validate prior exposure to nitrogen mustards (HN-1, HN-2, and HN-3) or sulfur mustard (HD) in a single run, which significantly reduces analysis time compared to separate runs to screen for different mustards' biomarkers based on tandem mass spectrometry. Belonging to one of the more toxic classes of chemical warfare agents, these potent vesicants bind covalently to the cysteine-34 residue of human serum albumin. This results in the formation of stable adducts whose identities were confirmed by a de novo sequencing bioinformatics software package. Our developed technique tracks these albumin-derived adduct biomarkers in blood samples which persist in vitro following exposure, enabling a detection limit of 200 nM of HN-1, 100 nM of HN-2, 200 nM of HN-3, or 50 nM of HD in human blood. The CWA-adducts formed in blood samples can be conveniently and sensitively analyzed by this MRM technique to allow rapid and reliable screening.
EDTA-temperature-Induced pseudohematocytopenia in a patient with multiple myeloma.
Zhang, Lixia; Pan, Shiyang; Zhang, Jie; Lu, Lin; Xie, Erfu; Ye, Qin
2012-01-01
Platelet clumping caused by ethylenediamine tetraacetic acid (EDTA) and erythrocyte agglutination caused by cold agglutinins are often found in clinical findings. However, erythrocyte agglutination induced by EDTA has not been reported as yet. Spurious low red blood cell (RBC), white blood cell (WBC), and platelet counts were observed in a patient blood sample collected in EDTA in vitro at room temperature and 37 degrees C. However, the phenomena were only observed in the sodium citrate and heparin anticoagulated blood at room temperature, but not at 37 degrees C. Both erythrocyte agglutination and platelet clumping were observed in the peripheral blood smear. These data suggest an EDTA-temperature-induced pseudohematocytopenia. It is a very rare phenomenon to observe erythrocyte agglutination induced by EDTA and temperature.
Antelo-Domínguez, Ángel; Cocho, José Ángel; Tabernero, María Jesús; Bermejo, Ana María; Bermejo-Barrera, Pilar; Moreda-Piñeiro, Antonio
2013-12-15
A sample pre-treatment method based on blood spot collection filter cards was optimized as a means of using small volume samples for the screening and confirmation of cocaine and opiates abuse. Dried blood spots (DBSs) were prepared by dispersing 20 µL of whole blood specimens previously mixed with the internal standards (deuterated analogs of each target), and subjecting the whole DBS to extraction with 5 mL of methanol under orbital-horizontal shaking (180 rpm) for 10 min. Determinations were based on direct electrospray ionization tandem mass spectrometry (ESI-MS/MS) by injecting the re-dissolved methanol extract with the delivery solution (acetonitrile-water-formic acid, 80:19.875:0.125) at a flow rate of 60 µL min(-1), and using multiple reaction monitoring (MRM) mode with the m/z (precursor ion)→m/z (product ion) transitions for acquisition. Matrix effect has been found to be statistically significant (Multiple Range Test) when assessing cocaine, BZE, codeine and morphine, and the use of the standard addition method (dispersion of whole blood previously mixed with standards onto the filter papers) was needed for accurate determinations. The developed DBS-ESI-MS/MS procedure offered good intra-day and inter-day precisions (lower than 10% and 12%, respectively), as well as good intra-day and inter-day accuracies (inter-day absolute recoveries, expressed as the mean analytical recovery over three target concentration levels, of 103%, 100%, 101%, 98% and 100% for cocaine, BZE, codeine, morphine and 6-MAM, respectively). The high sensitivity inherent to MS/MS determinations combined with the minimal dilution of sample allowed low limits of quantification for all targets, and the developed method results therefore adequate for cocaine and opiates screening and confirmation purposes. The procedure was finally applied to DBSs prepared from whole blood from polydrug abusers, and results were compared with those obtained after a conventional sample pretreatment method based on solid phase extraction for plasma specimens and gas chromatography-mass spectrometry. © 2013 Elsevier B.V. All rights reserved.
Pharmacokinetics of isotretinoin during repetitive dosing to patients.
Brazzell, R K; Vane, F M; Ehmann, C W; Colburn, W A
1983-01-01
The multiple dose pharmacokinetics of isotretinoin and its major blood metabolite, 4-oxo-isotretinoin, were studied in 10 patients with cystic acne and 11 patients with various keratinization disorders. Blood samples were obtained at predetermined times following the first dose, interim doses and the final dose. Blood concentrations of isotretinoin and 4-oxo-isotretinoin were measured by a specific and sensitive HPLC method. A lag time was usually observed prior to the onset of absorption following oral administration of the drug in a soft elastic gelatin capsule. Absorption then proceeded rapidly and maximum blood concentrations usually occurred within 4 h of drug administration. The harmonic mean half-life for the elimination of isotretinoin by the cystic acne patients was approximately 10 h after the initial dose and did not change significantly following 25 days of 40 mg b.i.d. dosing. Steady-state blood concentrations remained relatively constant after the fifth day of dosing. The harmonic mean elimination half-life in the patients with various disorders of keratinization was about 16 h. The results of the 2 studies suggest that no significant changes in the pharmacokinetics of isotretinoin occur during multiple dosing and that the multiple dose pharmacokinetic profile is predictable and can be described using a linear pharmacokinetic model. This suggests that the steady-state concentrations of isotretinoin can be predicted from single dose data.
Methods to Detect Nitric Oxide and its Metabolites in Biological Samples
Bryan, Nathan S.; Grisham, Matthew B.
2007-01-01
Nitric oxide (NO) methodology is a complex and often confusing science and the focus of many debates and discussion concerning NO biochemistry. NO is involved in many physiological processes including regulation of blood pressure, immune response and neural communication. Therefore its accurate detection and quantification is critical to understanding health and disease. Due to the extremely short physiological half life of this gaseous free radical, alternative strategies for the detection of reaction products of NO biochemistry have been developed. The quantification of NO metabolites in biological samples provides valuable information with regards to in vivo NO production, bioavailability and metabolism. Simply sampling a single compartment such as blood or plasma may not always provide an accurate assessment of whole body NO status, particularly in tissues. Therefore, extrapolation of plasma or blood NO status to specific tissues of interest is no longer a valid approach. As a result, methods continue to be developed and validated which allow the detection and quantification of NO and NO-related products/metabolites in multiple compartments of experimental animals in vivo. The methods described in this review is not an exhaustive or comprehensive discussion of all methods available for the detection of NO but rather a description of the most commonly used and practical methods which allow accurate and sensitive quantification of NO products/metabolites in multiple biological matrices under normal physiological conditions. PMID:17664129
Moroni, Maria; Coolbaugh, Thea V; Mitchell, Jennifer M; Lombardini, Eric; Moccia, Krinon D; Shelton, Larry J; Nagy, Vitaly; Whitnall, Mark H
2011-01-01
Threats of nuclear and other radiologic exposures have been increasing, but no countermeasure for acute radiation syndrome has been approved by regulatory authorities. Because of their similarity to humans in regard to physiology and anatomy, we are characterizing Gottingen minipigs as a model to aid the development of radiation countermeasures. Irradiated minipigs exhibit immunosuppression, severe thrombocytopenia, vascular leakage, and acute inflammation. These complications render serial acquisition of blood samples problematic. Vascular access ports (VAP) facilitate serial sampling, but their use often is complicated by infections and fibrin deposition. We demonstrate here the successful use of VAP for multiple blood samplings in irradiated minipigs. Device design and limited postoperative prophylactic antimicrobial therapy before irradiation were key to obtaining serial sampling, reducing swelling, and eliminating infection and skin necrosis at the implantation site. Modifications of previous protocols included the use of polydioxanone sutures instead of silk; eliminating chronic port access; single-use, sterile, antireflux prefilled syringes for flushing; strict aseptic weekly maintenance of the device, and acclimating animals to reduce stress. VAP remained functional in 19 of 20 irradiated animals for as long as 3 mo. The remaining VAP failed due to a small leak in the catheter, leading to clot formation. VAP-related sepsis occurred in 2 minipigs. Blood sampling did not cause detectable stress in nonanesthetized sham-irradiated animals, according to leukograms and clinical signs. PMID:21333166
Zheng, Zhi; Luo, Yuling; McMaster, Gary K
2006-07-01
Accurate and precise quantification of mRNA in whole blood is made difficult by gene expression changes during blood processing, and by variations and biases introduced by sample preparations. We sought to develop a quantitative whole-blood mRNA assay that eliminates blood purification, RNA isolation, reverse transcription, and target amplification while providing high-quality data in an easy assay format. We performed single- and multiplex gene expression analysis with multiple hybridization probes to capture mRNA directly from blood lysate and used branched DNA to amplify the signal. The 96-well plate singleplex assay uses chemiluminescence detection, and the multiplex assay combines Luminex-encoded beads with fluorescent detection. The single- and multiplex assays could quantitatively measure as few as 6000 and 24,000 mRNA target molecules (0.01 and 0.04 amoles), respectively, in up to 25 microL of whole blood. Both formats had CVs < 10% and dynamic ranges of 3-4 logs. Assay sensitivities allowed quantitative measurement of gene expression in the minority of cells in whole blood. The signals from whole-blood lysate correlated well with signals from purified RNA of the same sample, and absolute mRNA quantification results from the assay were similar to those obtained by quantitative reverse transcription-PCR. Both single- and multiplex assay formats were compatible with common anticoagulants and PAXgene-treated samples; however, PAXgene preparations induced expression of known antiapoptotic genes in whole blood. Both the singleplex and the multiplex branched DNA assays can quantitatively measure mRNA expression directly from small volumes of whole blood. The assay offers an alternative to current technologies that depend on RNA isolation and is amenable to high-throughput gene expression analysis of whole blood.
Hansen, Heidi; Ben-David, Merav; McDonald, David B
2008-03-01
In noninvasive genetic sampling, when genotyping error rates are high and recapture rates are low, misidentification of individuals can lead to overestimation of population size. Thus, estimating genotyping errors is imperative. Nonetheless, conducting multiple polymerase chain reactions (PCRs) at multiple loci is time-consuming and costly. To address the controversy regarding the minimum number of PCRs required for obtaining a consensus genotype, we compared consumer-style the performance of two genotyping protocols (multiple-tubes and 'comparative method') in respect to genotyping success and error rates. Our results from 48 faecal samples of river otters (Lontra canadensis) collected in Wyoming in 2003, and from blood samples of five captive river otters amplified with four different primers, suggest that use of the comparative genotyping protocol can minimize the number of PCRs per locus. For all but five samples at one locus, the same consensus genotypes were reached with fewer PCRs and with reduced error rates with this protocol compared to the multiple-tubes method. This finding is reassuring because genotyping errors can occur at relatively high rates even in tissues such as blood and hair. In addition, we found that loci that amplify readily and yield consensus genotypes, may still exhibit high error rates (7-32%) and that amplification with different primers resulted in different types and rates of error. Thus, assigning a genotype based on a single PCR for several loci could result in misidentification of individuals. We recommend that programs designed to statistically assign consensus genotypes should be modified to allow the different treatment of heterozygotes and homozygotes intrinsic to the comparative method. © 2007 The Authors.
Grignard, Lynn; Gonçalves, Bronner P; Early, Angela M; Daniels, Rachel F; Tiono, Alfred B; Guelbéogo, Wamdaogo M; Ouédraogo, Alphonse; van Veen, Elke M; Lanke, Kjerstin; Diarra, Amidou; Nebie, Issa; Sirima, Sodiomon B; Targett, Geoff A; Volkman, Sarah K; Neafsey, Daniel E; Wirth, Dyann F; Bousema, Teun; Drakeley, Chris
2018-05-05
Plasmodium falciparum malaria infections often comprise multiple distinct parasite clones. Few datasets have directly assessed infection complexity in humans and mosquitoes they infect. Examining parasites using molecular tools may provide insights into the selective transmissibility of isolates. Using capillary electrophoresis genotyping and next generation amplicon sequencing, we analysed complexity of parasite infections in human blood and in the midguts of mosquitoes that became infected in membrane feeding experiments using the same blood material in two West African settings. Median numbers of clones in humans and mosquitoes were higher in samples from Burkina Faso (4.5, interquartile range 2-8 for humans; and 2, interquartile range 1-3 for mosquitoes) than in The Gambia (2, interquartile range 1-3 and 1, interquartile range 1-3, for humans and mosquitoes, respectively). Whilst the median number of clones was commonly higher in human blood samples, not all transmitted alleles were detectable in the human peripheral blood. In both study sample sets, additional parasite alleles were identified in mosquitoes compared with the matched human samples (10-88.9% of all clones/feeding assay, n = 73 feeding assays). The results are likely due to preferential amplification of the most abundant clones in peripheral blood but confirm the presence of low density clones that produce transmissible sexual stage parasites. Copyright © 2018. Published by Elsevier Ltd.
Nieva, Jorge; Wendel, Marco; Luttgen, Madelyn S; Marrinucci, Dena; Bazhenova, Lyudmila; Kolatkar, Anand; Santala, Roger; Whittenberger, Brock; Burke, James; Torrey, Melissa; Bethel, Kelly; Kuhn, Peter
2012-02-01
Sampling circulating tumor cells (CTCs) from peripheral blood is ideally accomplished using assays that detect high numbers of cells and preserve them for downstream characterization. We sought to evaluate a method using enrichment free fluorescent labeling of CTCs followed by automated digital microscopy in patients with non-small cell lung cancer. Twenty-eight patients with non-small cell lung cancer and hematogenously seeded metastasis were analyzed with multiple blood draws. We detected CTCs in 68% of analyzed samples and found a propensity for increased CTC detection as the disease progressed in individual patients. CTCs were present at a median concentration of 1.6 CTCs ml⁻¹ of analyzed blood in the patient population. Higher numbers of detected CTCs were associated with an unfavorable prognosis.
Relationship between vapor intrusion and human exposure to trichloroethylene.
Archer, Natalie P; Bradford, Carrie M; Villanacci, John F; Crain, Neil E; Corsi, Richard L; Chambers, David M; Burk, Tonia; Blount, Benjamin C
2015-01-01
Trichloroethylene (TCE) in groundwater has the potential to volatilize through soil into indoor air where it can be inhaled. The purpose of this study was to determine whether individuals living above TCE-contaminated groundwater are exposed to TCE through vapor intrusion. We examined associations between TCE concentrations in various environmental media and TCE concentrations in residents. For this assessment, indoor air, outdoor air, soil gas, and tap water samples were collected in and around 36 randomly selected homes; blood samples were collected from 63 residents of these homes. Additionally, a completed exposure survey was collected from each participant. Environmental and blood samples were analyzed for TCE. Mixed model multiple linear regression analyses were performed to determine associations between TCE in residents' blood and TCE in indoor air, outdoor air, and soil gas. Blood TCE concentrations were above the limit of quantitation (LOQ; ≥ 0.012 µg L(-1)) in 17.5% of the blood samples. Of the 36 homes, 54.3%, 47.2%, and >84% had detectable concentrations of TCE in indoor air, outdoor air, and soil gas, respectively. Both indoor air and soil gas concentrations were statistically significantly positively associated with participants' blood concentrations (P = 0.0002 and P = 0.04, respectively). Geometric mean blood concentrations of residents from homes with indoor air concentrations of >1.6 µg m(-3) were approximately 50 times higher than geometric mean blood TCE concentrations in participants from homes with no detectable TCE in indoor air (P < .0001; 95% CI 10.4-236.4). This study confirms the occurrence of vapor intrusion and demonstrates the magnitude of exposure from vapor intrusion of TCE in a residential setting.
Relationship between vapor intrusion and human exposure to trichloroethylene
ARCHER, NATALIE P.; BRADFORD, CARRIE M.; VILLANACCI, JOHN F.; CRAIN, NEIL E.; CORSI, RICHARD L.; CHAMBERS, DAVID M.; BURK, TONIA; BLOUNT, BENJAMIN C.
2015-01-01
Trichloroethylene (TCE) in groundwater has the potential to volatilize through soil into indoor air where it can be inhaled. The purpose of this study was to determine whether individuals living above TCE-contaminated groundwater are exposed to TCE through vapor intrusion. We examined associations between TCE concentrations in various environmental media and TCE concentrations in residents. For this assessment, indoor air, outdoor air, soil gas, and tap water samples were collected in and around 36 randomly selected homes; blood samples were collected from 63 residents of these homes. Additionally, a completed exposure survey was collected from each participant. Environmental and blood samples were analyzed for TCE. Mixed model multiple linear regression analyses were performed to determine associations between TCE in residents' blood and TCE in indoor air, outdoor air, and soil gas. Blood TCE concentrations were above the limit of quantitation (LOQ; ≥0.012 μg/L) in 17.5% of the blood samples. Of the 36 homes, 54.3%, 47.2%, and >84% had detectable concentrations of TCE in indoor air, outdoor air, and soil gas, respectively. Both indoor air and soil gas concentrations were statistically significantly positively associated with participants' blood concentrations (p=0.0002 and p=0.04, respectively). Geometric mean blood concentrations of residents from homes with indoor air concentrations of >1.6 μg/m3 were approximately 50 times higher than geometric mean blood TCE concentrations in participants from homes with no detectable TCE in indoor air (p<.0001; 95% CI 10.4 – 236.4). This study confirms the occurrence of vapor intrusion and demonstrates the magnitude of exposure from vapor intrusion of TCE in a residential setting. PMID:26259926
Gas chromatography-mass spectrometry of biofluids and extracts.
Emwas, Abdul-Hamid M; Al-Talla, Zeyad A; Yang, Yang; Kharbatia, Najeh M
2015-01-01
Gas chromatography-mass spectrometry (GC-MS) has been widely used in metabonomics analyses of biofluid samples. Biofluids provide a wealth of information about the metabolism of the whole body and from multiple regions of the body that can be used to study general health status and organ function. Blood serum and blood plasma, for example, can provide a comprehensive picture of the whole body, while urine can be used to monitor the function of the kidneys, and cerebrospinal fluid (CSF) will provide information about the status of the brain and central nervous system (CNS). Different methods have been developed for the extraction of metabolites from biofluids, these ranging from solvent extracts, acids, heat denaturation, and filtration. These methods vary widely in terms of efficiency of protein removal and in the number of metabolites extracted. Consequently, for all biofluid-based metabonomics studies, it is vital to optimize and standardize all steps of sample preparation, including initial extraction of metabolites. In this chapter, recommendations are made of the optimum experimental conditions for biofluid samples for GC-MS, with a particular focus on blood serum and plasma samples.
Brennan, K A; Eapen, G; Turnbull, D
2010-04-01
In 2008, the National Patient Safety Agency (NPSA) published a report after 42 incidents and two deaths where glucose-containing flush solutions were attached to the arterial line. The molar concentration of 5% glucose is 277 mmol litre(-1). Only a tiny amount of sample contamination will lead to an artificially high glucose. As the NPSA sought a solution, a bench model was constructed to compare the performance of three open and three closed arterial line systems in limiting sample contamination. All arterial line systems were set up in a standard manner and pressurized to 300 mm Hg with 5% glucose used as the flush solution. This was connected to the 'radial artery' using an 18 G needle representing the radial cannula. The radial artery was simulated using a wide-bore extension set with 'blood' flow at 60 ml min(-1). Blood was simulated by the addition of red dye to Hartmann's solution. Increasing multiples of arterial line dead space were aspirated and discarded. Blood samples were then obtained and glucose concentration was measured. Significant glucose contamination (3 mmol litre(-1) +/-3.4) was detected in all open arterial line systems up to an aspiration volume of five times the dead space. No samples from the closed systems recorded glucose concentration >1 mmol litre(-1). Recommended minimal discard volumes are inadequate in the presence of glucose as the flush solution and can lead to high blood glucose readings, inappropriate insulin use, and iatrogenic neuroglycopaenia. Our study demonstrates that the closed-loop arterial sampling system could be the universal solution sought by the NPSA.
Lin, Wen-Ye; Chang, Jung-Tzu; Chu, Chun-Feng
2017-01-01
Despite measures to reduce disease transmission, a risk can occur when blood glucose meters (BGMs) are used on multiple individuals or by caregivers assisting a patient. The laboratory and in-clinic performance of a BGM system before and after disinfection should be demonstrated to guarantee accurate readings and reliable control of blood glucose (BG) for patients. In this study, an effective disinfection procedure, conducting wiping 10 times to assure a one minute contact time of the disinfectant on contaminated surface, was first demonstrated using test samples of the meter housing materials, including acrylonitrile butadiene styrene (ABS), polymethyl methacrylate (PMMA), and polycarbonate (PC), in accordance with ISO 15197:2013. After bench studies comprising 10,000 disinfection cycles, the elemental compositions of the disinfected ABS, PMMA, and PC samples were almost the same as in the original samples, as indicated by electron spectroscopy for chemical analysis. Subsequently, the validated disinfection procedure was then directly applied to disinfect 5 commercial BGM systems composed of ABS, PMMA, or PC to observe the effect of the validated disinfection procedure on meter accuracy. The results of HBsAg values after treatment with HBV sera and disinfectant wipes for each material were less than the LoD of each material of 0.020 IU/mL. Before and after the multiple disinfection cycles, 900 of 900 samples (100%) were within the system accuracy requirements of ISO 15197:2013. All of the systems showed high performance before and after the series of disinfection cycles and met the ISO 15197:2013 requirements. In addition, our results demonstrated multiple cleaning and disinfection cycles that represented normal use over the lifetime of a meter of 3–5 years. Our validated cleaning and disinfection procedure can be directly applied to other registered disinfectants for cleaning commercial BGM products in the future. PMID:28683148
Lin, Shu-Ping; Lin, Wen-Ye; Chang, Jung-Tzu; Chu, Chun-Feng
2017-01-01
Despite measures to reduce disease transmission, a risk can occur when blood glucose meters (BGMs) are used on multiple individuals or by caregivers assisting a patient. The laboratory and in-clinic performance of a BGM system before and after disinfection should be demonstrated to guarantee accurate readings and reliable control of blood glucose (BG) for patients. In this study, an effective disinfection procedure, conducting wiping 10 times to assure a one minute contact time of the disinfectant on contaminated surface, was first demonstrated using test samples of the meter housing materials, including acrylonitrile butadiene styrene (ABS), polymethyl methacrylate (PMMA), and polycarbonate (PC), in accordance with ISO 15197:2013. After bench studies comprising 10,000 disinfection cycles, the elemental compositions of the disinfected ABS, PMMA, and PC samples were almost the same as in the original samples, as indicated by electron spectroscopy for chemical analysis. Subsequently, the validated disinfection procedure was then directly applied to disinfect 5 commercial BGM systems composed of ABS, PMMA, or PC to observe the effect of the validated disinfection procedure on meter accuracy. The results of HBsAg values after treatment with HBV sera and disinfectant wipes for each material were less than the LoD of each material of 0.020 IU/mL. Before and after the multiple disinfection cycles, 900 of 900 samples (100%) were within the system accuracy requirements of ISO 15197:2013. All of the systems showed high performance before and after the series of disinfection cycles and met the ISO 15197:2013 requirements. In addition, our results demonstrated multiple cleaning and disinfection cycles that represented normal use over the lifetime of a meter of 3-5 years. Our validated cleaning and disinfection procedure can be directly applied to other registered disinfectants for cleaning commercial BGM products in the future.
Avian mercury exposure and toxicological risk across western North America: A synthesis
Ackerman, Joshua T.; Eagles-Smith, Collin A.; Herzog, Mark; Hartman, Christopher; Peterson, Sarah; Evers, David C.; Jackson, Allyson K.; Elliott, John E.; Vander Pol, Stacy S.; Bryan, Colleen E.
2016-01-01
Methylmercury contamination of the environment is an important issue globally, and birds are useful bioindicators for mercury monitoring programs. The available data on mercury contamination of birds in western North America were synthesized. Original data from multiple databases were obtained and a literature review was conducted to obtain additional mercury concentrations. In total, 29219 original bird mercury concentrations from 225 species were compiled, and an additional 1712 mean mercury concentrations, representing 19998 individuals and 176 species, from 200 publications were obtained. To make mercury data comparable across bird tissues, published equations of tissue mercury correlations were used to convert all mercury concentrations into blood-equivalent mercury concentrations. Blood-equivalent mercury concentrations differed among species, foraging guilds, habitat types, locations, and ecoregions. Piscivores and carnivores exhibited the greatest mercury concentrations, whereas herbivores and granivores exhibited the lowest mercury concentrations. Bird mercury concentrations were greatest in ocean and salt marsh habitats and lowest in terrestrial habitats. Bird mercury concentrations were above toxicity benchmarks in many areas throughout western North America, and multiple hotspots were identified. Additionally, published toxicity benchmarks established in multiple tissues were summarized and translated into a common blood-equivalent mercury concentration. Overall, 66% of birds sampled in western North American exceeded a blood-equivalent mercury concentration of 0.2 μg/g wet weight (ww; above background levels), which is the lowest-observed effect level, 28% exceeded 1.0 μg/g ww (moderate risk), 8% exceeded 3.0 μg/g ww (high risk), and 4% exceeded 4.0 μg/g ww (severe risk). Mercury monitoring programs should sample bird tissues, such as adult blood and eggs, that are most-easily translated into tissues with well-developed toxicity benchmarks and that are directly relevant to bird reproduction. Results indicate that mercury contamination of birds is prevalent in many areas throughout western North America, and large-scale ecological attributes are important factors influencing bird mercury concentrations.
Avian mercury exposure and toxicological risk across western North America: A synthesis
Ackerman, Joshua T.; Eagles-Smith, Collin A.; Herzog, Mark P.; Hartman, C. Alex; Peterson, Sarah H.; Evers, David C.; Jackson, Allyson K.; Elliott, John E.; Vander Pol, Stacy S.; Bryan, Colleen E.
2017-01-01
Methylmercury contamination of the environment is an important issue globally and birds are useful bioindicators for mercury monitoring programs. The available data on mercury contamination of birds in western North America were synthesized. Original data from multiple databases were obtained and a literature review was conducted to obtain additional mercury concentrations. In total, 29219 original bird mercury concentrations from 225 species were compiled, and an additional 1712 mean mercury concentrations, representing 19998 individuals and 176 species, from 200 publications were obtained. To make mercury data comparable across bird tissues, published equations of tissue mercury correlations were used to convert all mercury concentrations into blood-equivalent mercury concentrations. Blood-equivalent mercury concentrations differed among species, foraging guilds, habitat types, locations, and ecoregions. Piscivores and carnivores exhibited the greatest mercury concentrations, whereas herbivores and granivores exhibited the lowest mercury concentrations. Bird mercury concentrations were greatest in ocean and salt marsh habitats and lowest in terrestrial habitats. Bird mercury concentrations were above toxicity benchmarks in many areas throughout western North America, and multiple hotspots were identified. Additionally, published toxicity benchmarks established in multiple tissues were summarized and translated into a common blood-equivalent mercury concentration. Overall, 66% of birds sampled in western North American exceeded a blood-equivalent mercury concentration of 0.2 μg/g wet weight (ww; above background levels), which is the lowest-observed effect level, 28% exceeded 1.0 μg/g ww (moderate risk), 8% exceeded 3.0 μg/g ww (high risk), and 4% exceeded 4.0 μg/g ww (severe risk). Mercury monitoring programs should sample bird tissues, such as adult blood and eggs, that are most-easily translated into tissues with well-developed toxicity benchmarks and that are directly relevant to bird reproduction. Results indicate that mercury contamination of birds is prevalent in many areas throughout western North America, and large-scale ecological attributes are important factors influencing bird mercury concentrations. PMID:27093907
Ramirez-Arcos, Sandra; Mastronardi, Cherie; Perkins, Heather; Kou, Yuntong; Turner, Tracey; Mastronardi, Emily; Hansen, Adele; Yi, Qi-Long; McLaughlin, Natasha; Kahwash, Eiad; Lin, Yulia; Acker, Jason
2013-04-01
A 30-minute rule was established to limit red blood cell (RBC) exposure to uncontrolled temperatures during storage and transportation. Also, RBC units issued for transfusion should not remain at room temperature (RT) for more than 4 hours (4-hour rule). This study was aimed at determining if single or multiple RT exposures affect RBC quality and/or promote bacterial growth. Growth and RT exposure experiments were performed in RBCs inoculated with Serratia liquefaciens and Serratia marcescens. RBCs were exposed once to RT for 5 hours (S. liquefaciens) or five times to RT for 30 minutes (S. marcescens) with periodic sampling for bacterial counts. Noncontaminated units were exposed to RT once (5 hr) or five times (30 min each) and sampled to measure in vitro quality variables. RBC core temperature was monitored using mock units with temperature loggers. Growth and RT exposure experiments were repeated three and at least six times, respectively. Statistical analysis was done using mixed-model analysis. RBC core temperature ranged from 7.3 to 11.6°C during 30-minute RT exposures and the time to reach 10°C varied from 22 to 55 minutes during 5-hour RT exposures. RBC quality was preserved after single or multiple RT exposures. Increased growth of S. liquefaciens was only observed after 2 hours of continuous RT exposure. S. marcescens concentration increased significantly in multiple-exposed units compared to the controls but did not reach clinically important levels. Single or multiple RT exposures did not affect RBC quality but slightly promoted bacterial growth in contaminated units. The clinical significance of these results remains unclear and needs further investigation. © 2012 American Association of Blood Banks.
Gomez, E; Martin, D; Carrocera, S; Muñoz, M
2015-08-01
In cattle, the detection of very early endometrial responses is considered to be hampered by the presence of only a single embryo. Therefore, we have previously developed a model of multiple embryo transfer to circumvent this hindrance. In this work, we analysed embryo-maternal interactions in the bovine uterus on day 8 of development while comparing the presence of multiple v. single embryos using embryo transfer and artificial insemination, respectively. Concentration of proteins (β-actin, NFkB, clusterin and immunoproteosome 20S β5i subunit-i20S), by western blot, and hexoses (glucose and fructose) were measured in paired samples of uterine fluid (UF) from the same animal with and without embryos in the uterus and were compared with UF obtained after artificial insemination. Prostaglandin (PG) F2 α and PGE2 concentrations were also analysed in blood plasma. The four proteins analysed and hexoses were unaffected by the presence of one or more embryos in the uterus. However, blood PGF2 α showed similar, significant increases with one or more embryos over cyclic animals; such changes were not observed in blood PGE2. Although multiple embryo transfer may appear to be non-physiological, we showed that the uterus, at the very early embryonic stages, does exhibit physiological reactions. Multiple embryo transfer can, therefore, be used for studies of very early embryo-maternal interactions in vivo in monotocous species.
Wong, Koon-Pong; Zhang, Xiaoli; Huang, Sung-Cheng
2013-01-01
Purpose Accurate determination of the plasma input function (IF) is essential for absolute quantification of physiological parameters in positron emission tomography (PET). However, it requires an invasive and tedious procedure of arterial blood sampling that is challenging in mice because of the limited blood volume. In this study, a hybrid modeling approach is proposed to estimate the plasma IF of 2-deoxy-2-[18F]fluoro-D-glucose ([18F]FDG) in mice using accumulated radioactivity in urinary bladder together with a single late-time blood sample measurement. Methods Dynamic PET scans were performed on nine isoflurane-anesthetized male C57BL/6 mice after a bolus injection of [18F]FDG at the lateral caudal vein. During a 60- or 90-min scan, serial blood samples were taken from the femoral artery. Image data were reconstructed using filtered backprojection with CT-based attenuation correction. Total accumulated radioactivity in the urinary bladder was fitted to a renal compartmental model with the last blood sample and a 1-exponential function that described the [18F]FDG clearance in blood. Multiple late-time blood sample estimates were calculated by the blood [18F]FDG clearance equation. A sum of 4-exponentials was assumed for the plasma IF that served as a forcing function to all tissues. The estimated plasma IF was obtained by simultaneously fitting the [18F]FDG model to the time-activity curves (TACs) of liver and muscle and the forcing function to early (0–1 min) left-ventricle data (corrected for delay, dispersion, partial-volume effects and erythrocytes uptake) and the late-time blood estimates. Using only the blood sample acquired at the end of the study to estimate the IF and the use of liver TAC as an alternative IF were also investigated. Results The area under the plasma TACs calculated for all studies using the hybrid approach was not significantly different from that using all blood samples. [18F]FDG uptake constants in brain, myocardium, skeletal muscle and liver computed by the Patlak analysis using estimated and measured plasma TACs were in excellent agreement (slope ~ 1; R2 > 0.938). The IF estimated using only the last blood sample acquired at the end of the study and the use of liver TAC as plasma IF provided less reliable results. Conclusions The estimated plasma IFs obtained with the hybrid model agreed well with those derived from arterial blood sampling. Importantly, the proposed method obviates the need of arterial catheterization, making it possible to perform repeated dynamic [18F]FDG PET studies on the same animal. Liver TAC is unsuitable as an input function for absolute quantification of [18F]FDG PET data. PMID:23322346
Blood culture results from healthy captive and free-ranging elasmobranchs.
Mylniczenko, Natalie D; Harris, Brigita; Wilborn, Rachel E; Young, Forrest A
2007-09-01
Blood culture is a diagnostic tool used in confirming bacterial disease in teleostean and elasmobranch fishes. Unlike teleosts, elasmobranchs have a normal microflora in multiple organs, but their blood has generally been considered to be sterile. In regular exams of elasmobranchs conducted at a public aquarium, occasional blood samples have tested positive on culture. This finding prompted a blood culture survey of healthy captive and wild elasmobranchs (sharks and stingrays), which showed that 26.7% of all animals were positive. Stingrays alone showed a 50% occurrence of positive blood cultures, although the total number of animals was low and freshwater species were included in this number. When elasmobranchs other than stingrays were evaluated according to metabolic category, pelagic animals had a higher percentage of positive cultures than nonpelagic animals (38.7% versus 13.9%). These results indicate that a single positive blood culture without other corroborating diagnostics is not sufficient to confirm septicemia in elasmobranchs.
Serieys, Laurel E.K.; Armenta, Tiffany C.; Moriarty, Joanne G.; Boydston, Erin E.; Lyren, Lisa M.; Poppenga, Robert H.; Crooks, Kevin R.; Wayne, Robert K.; Riley, Seth P. D.
2015-01-01
Anticoagulant rodenticides (ARs) are increasingly recognized as a threat to nontarget wildlife. High exposure to ARs has been documented globally in nontarget predatory species and linked to the high prevalence of an ectoparasitic disease, notoedric mange. In southern California, mange associated with AR exposure has been the proximate cause of a bobcat (Lynx rufus) population decline. We measured AR exposure in bobcats from two areas in southern California, examining seasonal, demographic and spatial risk factors across landscapes including natural and urbanized areas. The long-term study included bobcats sampled over a 16-year period (1997–2012) and a wide geographic area. We sampled blood (N = 206) and liver (N = 172) to examine exposure ante- and post-mortem. We detected high exposure prevalence (89 %, liver; 39 %, blood) and for individuals with paired liver and blood data (N = 64), 92 % were exposed. Moreover, the animals with the most complete sampling were exposed most frequently to three or more compounds. Toxicant exposure was associated with commercial, residential, and agricultural development. Bobcats of both sexes and age classes were found to be at high risk of exposure, and we documented fetal transfer of multiple ARs. We found a strong association between certain levels of exposure (ppm), and between multiple AR exposure events, and notoedric mange. AR exposure was prevalent throughout both regions sampled and throughout the 16-year time period in the long-term study. ARs pose a substantial threat to bobcats, and likely other mammalian and avian predators, living at the urban-wildland interface.
2008-01-01
strategies, increasing the prevalence of both hypoglycemia and anemia in the ICU.14–20 The change in allogeneic blood transfusion practices occurred in...measurements in samples with low HCT levels.4,5,7,8,12 The error occurs because de- creased red blood cell causes less displacement of plasma, resulting...Nonlinear component regression was performed be- cause HCT has a nonlinear effect on accuracy of POC glucometers. A dual parameter correction factor was
Störmer, M; Cassens, U; Kleesiek, K; Dreier, J
2007-02-01
Bacteria show differences in their growth kinetics depending on the type of blood component. On to storage at 22 degrees C, platelet concentrates (PCs) seem to be more prone to bacterial multiplication than red cell concentrates. Knowledge of the potential for bacterial proliferation in blood components, which are stored at a range of temperatures, is essential before considering implementation of a detection strategy. The efficacy of bacterial detection was determined, using real-time reverse transcriptase-polymerase chain reaction (RT-PCR), following bacterial growth in blood components obtained from a deliberately contaminated whole-blood (WB) unit. Cultivation was used as the reference method. WB was spiked with 2 colony-forming units mL(-1)Staphylococcus epidermidis or Klebsiella pneumoniae, kept for 15 h at room temperature and component preparation was processed. Samples were drawn, at intervals throughout the whole separation process, from each blood component. Nucleic acids were extracted using an automated high-volume extraction method. The 15-h storage revealed an insignificant increase in bacterial titre. No bacterial growth was detected in red blood cell or plasma units. K. pneumoniae showed rapid growth in the pooled PC and could be detected immediately after preparation using RT-PCR. S. epidermidis grew slowly and was detected 24 h after separation. These experiments show that sampling is indicative at 24 h after preparation of PCs at the earliest to minimize the sampling error.
Chrysohoou, Christina; Panagiotakos, Demosthenes B; Pitsavos, Christos; Skoumas, John; Economou, Manolis; Papadimitriou, Lambros; Stefanadis, Christodoulos
2007-05-01
We sought to evaluate the association between pre-hypertension status and oxidative stress markers (total antioxidant capacity (TAC) and oxidized low density lipoprotein (LDL)), in a random sample of cardiovascular disease-free adults. The ATTICA study is a cross-sectional population-based survey that conducted in Attica region during 2001-2002. Based on a multistage and stratified random sampling, 1514 men and 1528 women (18-89 years old) were enrolled. The survey included a detailed interview; blood samples collected after 12h of fasting and, among other clinical measurements, status of blood pressure levels was evaluated. Six hundred and fifty-three men (43%) and 535 women (35%) were defined as pre-hypertensives. Both systolic and diastolic blood pressures were inversely correlated with TAC (p<0.001) and positively correlated to oxidized LDL (p<0.001). Particularly, compared to normotensive subjects, pre-hypertensives had 7% lower TAC levels (p<0.001) and 15% higher oxidized LDL levels (p<0.05), after correcting for multiple comparisons and adjusting for age, body mass index, blood lipids, glucose, food groups consumed and other potential confounders. Studying a large sample of cardiovascular disease-free adults, we revealed an association of pre-hypertension with oxidative stress markers linking to atherosclerotic process.
Fassunke, Jana; Ihle, Michaela Angelika; Lenze, Dido; Lehmann, Annika; Hummel, Michael; Vollbrecht, Claudia; Penzel, Roland; Volckmar, Anna-Lena; Stenzinger, Albrecht; Endris, Volker; Jung, Andreas; Lehmann, Ulrich; Zeugner, Silke; Baretton, Gustavo; Kreipe, Hans; Schirmacher, Peter; Kirchner, Thomas; Dietel, Manfred; Büttner, Reinhard; Merkelbach-Bruse, Sabine
2017-10-01
The European Commision (EC) recently approved osimertinib for the treatment of adult patients with locally advanced or metastatic non-small-cell lung cancer (NSCLC) harboring EGFR T790M mutations. Besides tissue-based testing, blood samples containing cell-free circulating tumor DNA (ctDNA) can be used to interrogate T790M status. Herein, we describe the conditions and results of a round robin trial (RRT) for T790M mutation testing in NSCLC tissue specimens and peripheral blood samples spiked with cell line DNA mimicking tumor-derived ctDNA. The underlying objectives of this two-staged external quality assessment (EQA) approach were (a) to evaluate the accuracy of T790M mutations testing across multiple centers and (b) to investigate if a liquid biopsy-based testing for T790M mutations in spiked blood samples is feasible in routine diagnostic. Based on a successfully completed internal phase I RRT, an open RRT for EGFR T790M mutation testing in tumor tissue and blood samples was initiated. In total, 48 pathology centers participated in the EQA. Of these, 47 (97.9%) centers submitted their analyses within the pre-defined time frame and 44 (tissue), respectively, 40 (plasma) successfully passed the test. The overall success rates in the RRT phase II were 91.7% (tissue) and 83.3% (blood), respectively. Thirty-eight out of 48 participants (79.2%) successfully passed both parts of the RRT. The RRT for blood-based EGFR testing initiated in Germany is, to the best of our knowledge, the first of his kind in Europe. In summary, our results demonstrate that blood-based genotyping for EGFR resistance mutations can be successfully integrated in routine molecular diagnostics complementing the array of molecular methods already available at pathology centers in Germany.
Vázquez Bahéna, Analine Berenice; Talavera Mendoza, Oscar; Moreno Godínez, Ma Elena; Salgado Souto, Sergio Adrián; Ruiz, Joaquín; Huerta Beristain, Gerardo
2017-04-01
The concentration and isotopic composition of lead in the blood of forty seven women of reproductive age (15-45y) exposed to multiple sources in two rural communities of the mining region of Taxco, Guerrero in southern Mexico were determined in order to identify specific contributing sources and their apportionment and to trace probable ingestion pathways. Our data indicate that >36% of the studied women have blood lead concentrations above 10μgdL -1 and up to 87% above 5μgdL -1 . Tailings contain between 2128 and 5988mgkg -1 of lead and represent the most conspicuous source in the area. Lead contents in indoor dust are largely variable (21.7-987mgkg -1 ) but only 15% of samples are above the Mexican Regulatory Guideline for urban soils (400mgkg -1 ). By contrast, 85% of glazed containers (range: 0.026-68.6mgkg -1 ) used for cooking and food storage are above the maximum 2mgL -1 of soluble lead established in the Mexican Guideline. The isotopic composition indicates that lead in the blood of 95% of the studied women can be modeled in terms of a mixing system between local ores (and derivatives), glazed pottery and Morelos bedrock, end-members, with the two former being largely the most important contributors. Only one sample shows influence of indoor paints. Indoor dust is dominated by ores and derivatives but some samples show evidence of contribution from a less radiogenic source very likely represented by interior paints. This study supports the application of lead isotopic ratios to identify potential sources and their apportionment in humans exposed to multiple sources of lead from both, natural and anthropogenic origin. Copyright © 2017 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koh, Chung-Yan; Piccini, Matthew Ernest; Schaff, Ulrich Y.
Multiple cases of attempted bioterrorism events using biotoxins have highlighted the urgent need for tools capable of rapid screening of suspect samples in the field (e.g., mailroom and public events). We present a portable microfluidic device capable of analyzing environmental (e.g., white powder), food (e.g., milk) and clinical (e.g., blood) samples for multiplexed detection of biotoxins. The device is rapid (<15-30 min sample-to-answer), sensitive (< 0.08 pg/mL detection limit for botulinum toxin), multiplexed (up to 64 parallel assays) and capable of analyzing small volume samples (< 20 μL total sample input). The immunoassay approach (SpinDx) is based on binding ofmore » toxins in a sample to antibody-laden capture particles followed by sedimentation of particles through a density-media in a microfluidic disk and quantification using a laser-induced fluorescence detector. A direct, blinded comparison with a gold standard ELISA revealed a 5-fold more sensitive detection limit for botulinum toxin while requiring 250-fold less sample volume and a 30 minute assay time with a near unity correlation. A key advantage of the technique is its compatibility with a variety of sample matrices with no additional sample preparation required. Ultrasensitive quantification has been demonstrated from direct analysis of multiple clinical, environmental and food samples, including white powder, whole blood, saliva, salad dressing, whole milk, peanut butter, half and half, honey, and canned meat. We believe that this device can met an urgent need in screening both potentially exposed people as well as suspicious samples in mail-rooms, airports, public sporting venues and emergency rooms. The general-purpose immunodiagnostics device can also find applications in screening of infectious and systemic diseases or serve as a lab device for conducting rapid immunoassays.« less
Blood gases, biochemistry and haematology of Galápagos hawksbill turtles (Eretmochelys imbricata)
Muñoz-Pérez, Juan Pablo; Hirschfeld, Maximilian; Alarcón-Ruales, Daniela; Denkinger, Judith; Castañeda, Jason Guillermo; García, Juan; Lohmann, Kenneth J.
2017-01-01
Abstract The hawksbill turtle, Eretmochelys imbricata, is a marine chelonian with a circum-global distribution, but the species is critically endangered and has nearly vanished from the eastern Pacific. Although reference blood parameter intervals have been published for many chelonian species and populations, including nesting Atlantic hawksbills, no such baseline biochemical and blood gas values have been reported for wild Pacific hawksbill turtles. Blood samples were drawn from eight hawksbill turtles captured in near shore foraging locations within the Galápagos archipelago over a period of four sequential years; three of these turtles were recaptured and sampled on multiple occasions. Of the eight sea turtles sampled, five were immature and of unknown sex, and the other three were females. A portable blood analyzer was used to obtain near immediate field results for a suite of blood gas and chemistry parameters. Values affected by temperature were corrected in two ways: (i) with standard formulas and (ii) with auto-corrections made by the portable analyzer. A bench top blood chemistry analyzer was used to measure a series of biochemistry parameters from plasma. Standard laboratory haematology techniques were employed for red and white blood cell counts and to determine haematocrit manually, which was compared to the haematocrit values generated by the portable analyzer. The values reported in this study provide reference data that may be useful in comparisons among populations and in detecting changes in health status among Galápagos sea turtles. The findings might also be helpful in future efforts to demonstrate associations between specific biochemical parameters and disease or environmental disasters. PMID:28496982
Blood gases, biochemistry and haematology of Galápagos hawksbill turtles (Eretmochelys imbricata).
Muñoz-Pérez, Juan Pablo; Lewbart, Gregory A; Hirschfeld, Maximilian; Alarcón-Ruales, Daniela; Denkinger, Judith; Castañeda, Jason Guillermo; García, Juan; Lohmann, Kenneth J
2017-01-01
The hawksbill turtle, Eretmochelys imbricata , is a marine chelonian with a circum-global distribution, but the species is critically endangered and has nearly vanished from the eastern Pacific. Although reference blood parameter intervals have been published for many chelonian species and populations, including nesting Atlantic hawksbills, no such baseline biochemical and blood gas values have been reported for wild Pacific hawksbill turtles. Blood samples were drawn from eight hawksbill turtles captured in near shore foraging locations within the Galápagos archipelago over a period of four sequential years; three of these turtles were recaptured and sampled on multiple occasions. Of the eight sea turtles sampled, five were immature and of unknown sex, and the other three were females. A portable blood analyzer was used to obtain near immediate field results for a suite of blood gas and chemistry parameters. Values affected by temperature were corrected in two ways: (i) with standard formulas and (ii) with auto-corrections made by the portable analyzer. A bench top blood chemistry analyzer was used to measure a series of biochemistry parameters from plasma. Standard laboratory haematology techniques were employed for red and white blood cell counts and to determine haematocrit manually, which was compared to the haematocrit values generated by the portable analyzer. The values reported in this study provide reference data that may be useful in comparisons among populations and in detecting changes in health status among Galápagos sea turtles. The findings might also be helpful in future efforts to demonstrate associations between specific biochemical parameters and disease or environmental disasters.
Associations between height and blood pressure in the United States population
Bourgeois, Brianna; Watts, Krista; Thomas, Diana M.; Carmichael, Owen; Hu, Frank B.; Heo, Moonseong; Hall, John E.; Heymsfield, Steven B.
2017-01-01
Abstract The mechanisms linking short stature with an increase in cardiovascular and cerebrovascular disease risk remain elusive. This study tested the hypothesis that significant associations are present between height and blood pressure in a representative sample of the US adult population. Participants were 12,988 men and women from a multiethnic sample (age ≥ 18 years) evaluated in the 1999 to 2006 National Health and Nutrition Examination Survey who were not taking antihypertensive medications and who had complete height, weight, % body fat, and systolic and diastolic arterial blood pressure (SBP and DBP) measurements; mean arterial blood pressure and pulse pressure (MBP and PP) were calculated. Multiple regression models for men and women were developed with each blood pressure as dependent variable and height, age, race/ethnicity, body mass index, % body fat, socioeconomic status, activity level, and smoking history as potential independent variables. Greater height was associated with significantly lower SBP and PP, and higher DBP (all P < .001) in combined race/ethnic–sex group models beginning in the 4th decade. Predicted blood pressure differences between people who are short and tall increased thereafter with greater age except for MBP. Socioeconomic status, activity level, and smoking history did not consistently contribute to blood pressure prediction models. Height-associated blood pressure effects were present in US adults who appeared in the 4th decade and increased in magnitude with greater age thereafter. These observations, in the largest and most diverse population sample evaluated to date, provide support for postulated mechanisms linking adult stature with cardiovascular and cerebrovascular disease risk. PMID:29390353
Wimsatt, Jeffrey; O'Shea, Thomas J; Ellison, Laura E; Pearce, Roger D; Price, Valerie R
2005-01-01
We anesthetized and blood sampled wild big brown bats (Eptesicus fuscus) in Fort Collins, Colorado (USA) in 2001 and 2002 and assessed effects on survival. Inhalant anesthesia was delivered into a specially designed restraint and inhalation capsule that minimized handling and bite exposures. Bats were immobilized an average of 9.1+/-5.1 (SD) min (range 1-71, n=876); blood sample volumes averaged 58+/-12 microl (range 13-126, n=718). We randomly selected control (subject to multiple procedures before release) and treatment (control procedures plus inhalant anesthesia and 1% of body weight blood sampling) groups in 2002 to assess treatment effects on daily survival over a 14-day period for adult female and volant juvenile bats captured at maternity roosts in buildings. We monitored survival after release using passive integrated transponder tag detection hoops placed at openings to selected roosts. Annual return rates of bats sampled in 2001 were used to assess long-term outcomes. Comparison of 14-day maximum-likelihood daily survival estimates from control (86 adult females, 92 volant juveniles) and treated bats (187 adult females, 87 volant juveniles) indicated no adverse effect from anesthesia and blood sampling (juveniles: chi2=22.22, df=27, P>0.05; adults: chi2=9.72, df=18, P>0.05). One-year return rates were similar among adult female controls (81%, n=72, 95% confidence interval [CI]=70-91%), females treated once (82%, n=276, 95% CI=81-84%), and females treated twice (84%, n=50, 95% CI=74-94%). Lack of an effect was also noted in 1-yr return rates of juvenile female controls (55%, n=29, 95% CI=37-73%), juveniles treated once (66%, n=113, 95% CI=58-75%), and juveniles treated twice (71%, n=17, 95% CI=49-92%). These data suggest that anesthesia and blood sampling for health monitoring did not measurably affect survival of adult female and volant juvenile big brown bats.
Hoffmayer, Eric R; Hendon, Jill M; Parsons, Glenn R; Driggers, William B; Campbell, Matthew D
2015-10-01
Elasmobranch stress responses are traditionally measured in the field by either singly or serially sampling an animal after a physiologically stressful event. Although capture and handling techniques are effective at inducing a stress response, differences in protocols could affect the degree of stress experienced by an individual, making meaningful comparisons between the protocols difficult, if not impossible. This study acutely stressed Atlantic sharpnose sharks, Rhizoprionodon terraenovae, by standardized capture (rod and reel) and handling methods and implemented either a single or serial blood sampling protocol to monitor four indicators of the secondary stress response. Single-sampled sharks were hooked and allowed to swim around the boat until retrieved for a blood sample at either 0, 15, 30, 45, or 60 min post-hooking. Serially sampled sharks were retrieved, phlebotomized, released while still hooked, and subsequently resampled at 15, 30, 45, and 60 min intervals post-hooking. Blood was analyzed for hematocrit, and plasma glucose, lactate, and osmolality levels. Although both single and serial sampling protocols resulted in an increase in glucose, no significant difference in glucose level was found between protocols. Serially sampled sharks exhibited cumulatively heightened levels for lactate and osmolality at all time intervals when compared to single-sampled animals at the same time. Maximal concentration differences of 217.5, 9.8, and 41.6 % were reported for lactate, osmolality, and glucose levels, respectively. Hematocrit increased significantly over time for the single sampling protocol but did not change significantly during the serial sampling protocol. The differences in resultant blood chemistry levels between implemented stress protocols and durations are significant and need to be considered when assessing stress in elasmobranchs.
Swoboda, Christine M; Miller, Carla K; Wills, Celia E
2016-08-01
The purpose of this study was to evaluate a 4-month telephone-based goal-setting and decision support intervention among adults with type 2 diabetes mellitus (T2DM) and multiple risk factors for cardiovascular disease (CVD). A randomized pretest-posttest control group design was employed. Overweight or obese adults aged 40 to 75 years with T2DM and ≥1 additional CVD risk factor were provided with individualized CVD risk information. At baseline and each biweekly telephone call, the multiple-goal group self-selected both diet- and physical activity-related goals, the single goal group set a single goal, and the control group received information about community health resources. Dietary intake was assessed via a food frequency questionnaire, physical activity via questionnaire, and A1C and blood lipids via fasting fingerstick sample. Between-group differences for clinical (ie, A1C, blood pressure, and blood lipids), physical activity, and dietary variables were evaluated using Kruskal-Wallis, Mann-Whitney U, analysis of variance, and t tests. From pre- to postintervention, the single-goal group demonstrated significant improvement in systolic blood pressure and intake of servings of fruits, vegetables, and refined grains (all P < .05). The multiple-goal group reported significant reduction in percent energy from total, saturated, monounsaturated, and trans fat intake and significant increase in leisure time walking (all P < .05). A multiple-goal approach over 4 months can improve dietary and physical activity outcomes, while a single-goal approach may facilitate improvement in one behavioral domain. Additional research is needed to evaluate maintenance of the achieved changes. © 2016 The Author(s).
Raab, Jennifer; Haupt, Florian; Scholz, Marlon; Matzke, Claudia; Warncke, Katharina; Lange, Karin; Assfalg, Robin; Weininger, Katharina; Wittich, Susanne; Löbner, Stephanie; Beyerlein, Andreas; Nennstiel-Ratzel, Uta; Lang, Martin; Laub, Otto; Dunstheimer, Desiree; Bonifacio, Ezio; Achenbach, Peter; Winkler, Christiane; Ziegler, Anette-G
2016-01-01
Introduction Type 1 diabetes can be diagnosed at an early presymptomatic stage by the detection of islet autoantibodies. The Fr1da study aims to assess whether early staging of type 1 diabetes (1) is feasible at a population-based level, (2) prevents severe metabolic decompensation observed at the clinical manifestation of type 1 diabetes and (3) reduces psychological distress through preventive teaching and care. Methods and analysis Children aged 2–5 years in Bavaria, Germany, will be tested for the presence of multiple islet autoantibodies. Between February 2015 and December 2016, 100 000 children will be screened by primary care paediatricians. Islet autoantibodies are measured in capillary blood samples using a multiplex three-screen ELISA. Samples with ELISA results >97.5th centile are retested using reference radiobinding assays. A venous blood sample is also obtained to confirm the autoantibody status of children with at least two autoantibodies. Children with confirmed multiple islet autoantibodies are diagnosed with pre-type 1 diabetes. These children and their parents are invited to participate in an education and counselling programme at a local diabetes centre. Depression and anxiety, and burden of early diagnosis are also assessed. Results Of the 1027 Bavarian paediatricians, 39.3% are participating in the study. Overall, 26 760 children have been screened between February 2015 and November 2015. Capillary blood collection was sufficient in volume for islet autoantibody detection in 99.46% of the children. The remaining 0.54% had insufficient blood volume collected. Of the 26 760 capillary samples tested, 0.39% were positive for at least two islet autoantibodies. Discussion Staging for early type 1 diabetes within a public health setting appears to be feasible. The study may set new standards for the early diagnosis of type 1 diabetes and education. Ethics dissemination The study was approved by the ethics committee of Technische Universität München (Nr. 70/14). PMID:27194320
Raab, Jennifer; Haupt, Florian; Scholz, Marlon; Matzke, Claudia; Warncke, Katharina; Lange, Karin; Assfalg, Robin; Weininger, Katharina; Wittich, Susanne; Löbner, Stephanie; Beyerlein, Andreas; Nennstiel-Ratzel, Uta; Lang, Martin; Laub, Otto; Dunstheimer, Desiree; Bonifacio, Ezio; Achenbach, Peter; Winkler, Christiane; Ziegler, Anette-G
2016-05-18
Type 1 diabetes can be diagnosed at an early presymptomatic stage by the detection of islet autoantibodies. The Fr1da study aims to assess whether early staging of type 1 diabetes (1) is feasible at a population-based level, (2) prevents severe metabolic decompensation observed at the clinical manifestation of type 1 diabetes and (3) reduces psychological distress through preventive teaching and care. Children aged 2-5 years in Bavaria, Germany, will be tested for the presence of multiple islet autoantibodies. Between February 2015 and December 2016, 100 000 children will be screened by primary care paediatricians. Islet autoantibodies are measured in capillary blood samples using a multiplex three-screen ELISA. Samples with ELISA results >97.5th centile are retested using reference radiobinding assays. A venous blood sample is also obtained to confirm the autoantibody status of children with at least two autoantibodies. Children with confirmed multiple islet autoantibodies are diagnosed with pre-type 1 diabetes. These children and their parents are invited to participate in an education and counselling programme at a local diabetes centre. Depression and anxiety, and burden of early diagnosis are also assessed. Of the 1027 Bavarian paediatricians, 39.3% are participating in the study. Overall, 26 760 children have been screened between February 2015 and November 2015. Capillary blood collection was sufficient in volume for islet autoantibody detection in 99.46% of the children. The remaining 0.54% had insufficient blood volume collected. Of the 26 760 capillary samples tested, 0.39% were positive for at least two islet autoantibodies. Staging for early type 1 diabetes within a public health setting appears to be feasible. The study may set new standards for the early diagnosis of type 1 diabetes and education. The study was approved by the ethics committee of Technische Universität München (Nr. 70/14). Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Relation of Urinary Calcium and Magnesium Excretion to Blood Pressure
Kesteloot†, Hugo; Tzoulaki, Ioanna; Brown, Ian J.; Chan, Queenie; Wijeyesekera, Anisha; Ueshima, Hirotsugu; Zhao, Liancheng; Dyer, Alan R.; Unwin, Robert J.; Stamler, Jeremiah; Elliott, Paul
2011-01-01
Data indicate an inverse association between dietary calcium and magnesium intakes and blood pressure (BP); however, much less is known about associations between urinary calcium and magnesium excretion and BP in general populations. The authors assessed the relation of BP to 24-hour excretion of calcium and magnesium in 2 cross-sectional studies. The International Study of Macro- and Micro-Nutrients and Blood Pressure (INTERMAP) comprised 4,679 persons aged 40–59 years from 17 population samples in China, Japan, the United Kingdom, and the United States, and the International Cooperative Study on Salt, Other Factors, and Blood Pressure (INTERSALT) comprised 10,067 persons aged 20–59 years from 52 samples around the world. Timed 24-hour urine collections, BP measurements, and nutrient data from four 24-hour dietary recalls (INTERMAP) were collected. In multiple linear regression analyses, urinary calcium excretion was directly associated with BP. After adjustment for multiple confounders (including weight, height, alcohol intake, calcium intake, urinary sodium level, and urinary potassium intake), systolic BP was 1.9 mm Hg higher per each 4.1 mmol per 24 hours (2 standard deviations) of higher urinary calcium excretion (associations were smaller for diastolic BP) in INTERMAP. Qualitatively similar associations were observed in INTERSALT analyses. Associations between magnesium excretion and BP were small and nonsignificant for most of the models examined. The present data suggest that altered calcium homoeostasis, as exhibited by increased calcium excretion, is associated with higher BP levels. PMID:21624957
Julander, Anneli; Lundgren, Lennart; Skare, Lizbet; Grandér, Margaretha; Palm, Brita; Vahter, Marie; Lidén, Carola
2014-12-01
Electrical and electronic waste (e-waste) contains multiple toxic metals. However, there is currently a lack of exposure data for metals on workers in formal recycling plants. The objective of this study was to evaluate workers' exposure to metals, using biomarkers of exposure in combination with monitoring of personal air exposure. We assessed exposure to 20 potentially toxic metals among 55 recycling workers and 10 office workers at three formal e-waste recycling plants in Sweden. Workers at two of the plants were followed-up after 6 months. We collected the inhalable fraction and OFC (37-mm) fraction of particles, using personal samplers, as well as spot samples of blood and urine. We measured metal concentrations in whole blood, plasma, urine, and air filters using inductively coupled plasma-mass spectrometry following acid digestion. The air sampling indicated greater airborne exposure, 10 to 30 times higher, to most metals among the recycling workers handling e-waste than among the office workers. The exposure biomarkers showed significantly higher concentrations of chromium, cobalt, indium, lead, and mercury in blood, urine, and/or plasma of the recycling workers, compared with the office workers. Concentrations of antimony, indium, lead, mercury, and vanadium showed close to linear associations between the inhalable particle fraction and blood, plasma, or urine. In conclusion, our study of formal e-waste recycling shows that workers performing recycling tasks are exposed to multiple toxic metals. Copyright © 2014. Published by Elsevier Ltd.
Accumulation and therapeutic modulation of 6-sulfo LacNAc(+) dendritic cells in multiple sclerosis.
Thomas, Katja; Dietze, Kristin; Wehner, Rebekka; Metz, Imke; Tumani, Hayrettin; Schultheiß, Thorsten; Günther, Claudia; Schäkel, Knut; Reichmann, Heinz; Brück, Wolfgang; Schmitz, Marc; Ziemssen, Tjalf
2014-10-01
To examine the potential role of 6-sulfo LacNAc(+) (slan) dendritic cells (DCs) displaying pronounced proinflammatory properties in the pathogenesis of multiple sclerosis (MS). We determined the presence of slanDCs in demyelinated brain lesions and CSF samples of patients with MS. In addition, we explored the impact of methylprednisolone, interferon-β, glatiramer acetate, or natalizumab on the frequency of blood-circulating slanDCs in patients with MS. We also evaluated whether interferon-β modulates important proinflammatory capabilities of slanDCs. SlanDCs accumulate in highly inflammatory brain lesions and are present in the majority of CSF samples of patients with MS. Short-term methylprednisolone administration reduces the percentage of slanDCs in blood of patients with MS and the proportion of tumor necrosis factor-α- or CD150-expressing slanDCs. Long-term interferon-β treatment decreases the percentage of blood-circulating slanDCs in contrast to glatiramer acetate or natalizumab. Furthermore, interferon-β inhibits the secretion of proinflammatory cytokines by slanDCs and their capacity to promote proliferation and differentiation of T cells. Accumulation of slanDCs in highly inflammatory brain lesions and their presence in CSF indicate that slanDCs may play an important role in the immunopathogenesis of MS. The reduction of blood-circulating slanDCs and the inhibition of their proinflammatory properties by methylprednisolone and interferon-β may contribute to the therapeutic efficiency of these drugs in patients with MS.
Accumulation and therapeutic modulation of 6-sulfo LacNAc+ dendritic cells in multiple sclerosis
Thomas, Katja; Dietze, Kristin; Wehner, Rebekka; Metz, Imke; Tumani, Hayrettin; Schultheiß, Thorsten; Günther, Claudia; Schäkel, Knut; Reichmann, Heinz; Brück, Wolfgang; Schmitz, Marc
2014-01-01
Objective: To examine the potential role of 6-sulfo LacNAc+ (slan) dendritic cells (DCs) displaying pronounced proinflammatory properties in the pathogenesis of multiple sclerosis (MS). Methods: We determined the presence of slanDCs in demyelinated brain lesions and CSF samples of patients with MS. In addition, we explored the impact of methylprednisolone, interferon-β, glatiramer acetate, or natalizumab on the frequency of blood-circulating slanDCs in patients with MS. We also evaluated whether interferon-β modulates important proinflammatory capabilities of slanDCs. Results: SlanDCs accumulate in highly inflammatory brain lesions and are present in the majority of CSF samples of patients with MS. Short-term methylprednisolone administration reduces the percentage of slanDCs in blood of patients with MS and the proportion of tumor necrosis factor-α– or CD150-expressing slanDCs. Long-term interferon-β treatment decreases the percentage of blood-circulating slanDCs in contrast to glatiramer acetate or natalizumab. Furthermore, interferon-β inhibits the secretion of proinflammatory cytokines by slanDCs and their capacity to promote proliferation and differentiation of T cells. Conclusion: Accumulation of slanDCs in highly inflammatory brain lesions and their presence in CSF indicate that slanDCs may play an important role in the immunopathogenesis of MS. The reduction of blood-circulating slanDCs and the inhibition of their proinflammatory properties by methylprednisolone and interferon-β may contribute to the therapeutic efficiency of these drugs in patients with MS. PMID:25340085
Seroepidemiology of toxoplasmosis among HIV-infected patients and healthy blood donors.
Nissapatorn, V; Kamarulzaman, A; Init, I; Tan, L H; Rohela, M; Norliza, A; Chan, L L; Latt, H M; Anuar, A Khairul; Quek, K F
2002-09-01
A cross-sectional study was carried out in University of Malaya Medical Centre, Kuala Lumpur. Blood samples from 100 HIV-infected patients and 203 Healthy Blood Donors (HBD) were collected and anti-Toxoplasma antibodies were detected by using conventional ELISA. The seroprevalence of toxoplasmosis in HIV/AIDS and Healthy Blood Donors were found to be 21% and 28.1% respectively. There was no significant association between the seroprevalence of toxoplasmosis and various possible risk factors i.e. contact with cat, consumption of undercooked meat and history of blood transfusion in both groups. No significant differences between Toxoplasma seroprevalence in HIV/AIDS and Healthy Blood Donors in association with presence of single or multiple risk factors were found. The mean CD4 count among HIV/AIDS patients in this study was 202.23 cell/cumm. There was no significant association between CD4 count and seropositivity for Toxoplasma antibodies in HIV/AIDS patients.
Microfluidic point-of-care blood panel based on a novel technique: Reversible electroosmotic flow
Mohammadi, Mahdi; Madadi, Hojjat; Casals-Terré, Jasmina
2015-01-01
A wide range of diseases and conditions are monitored or diagnosed from blood plasma, but the ability to analyze a whole blood sample with the requirements for a point-of-care device, such as robustness, user-friendliness, and simple handling, remains unmet. Microfluidics technology offers the possibility not only to work fresh thumb-pricked whole blood but also to maximize the amount of the obtained plasma from the initial sample and therefore the possibility to implement multiple tests in a single cartridge. The microfluidic design presented in this paper is a combination of cross-flow filtration with a reversible electroosmotic flow that prevents clogging at the filter entrance and maximizes the amount of separated plasma. The main advantage of this design is its efficiency, since from a small amount of sample (a single droplet ∼10 μl) almost 10% of this (approx 1 μl) is extracted and collected with high purity (more than 99%) in a reasonable time (5–8 min). To validate the quality and quantity of the separated plasma and to show its potential as a clinical tool, the microfluidic chip has been combined with lateral flow immunochromatography technology to perform a qualitative detection of the thyroid-stimulating hormone and a blood panel for measuring cardiac Troponin and Creatine Kinase MB. The results from the microfluidic system are comparable to previous commercial lateral flow assays that required more sample for implementing fewer tests. PMID:26396660
Karami, Masoumeh; Mehrabi, Farzad; Allameh, Abdolamir; Pahlevan Kakhki, Majid; Amiri, Mehdi; Emami Aleagha, Mohammad Sajad
2017-10-15
we recently showed that a hypothesized anti-aging and anti-inflammatory protein, namely Klotho, may contribute to the etiology and/or pathogenesis of multiple sclerosis (MS). In addition, Klotho function and its gene expression are dependent on inflammatory pathways. Accordingly, the aim of this study was to investigate the Klotho gene expression within peripheral blood mononuclear cells (PBMCs) of patients with MS. Altogether, 30 patients with relapsing-remitting MS (RRMS) along with 30 age and sex-matched healthy individuals were enrolled in this study. Blood samples were obtained from all participants and then PBMCs were isolated. The quantitative Real-Time PCR was carried out for Klotho mRNA derived from PBMCs. The results showed that klotho gene expression in the PBMCs of patients with RRMS is nearly 2.5-fold less than healthy individuals (P=0.0006). This is the first study demonstrating a possible role of Klotho in the PBMCs of MS patients. Copyright © 2017 Elsevier B.V. All rights reserved.
Gergov, M; Ojanperä, I; Vuori, E
2003-09-25
A liquid chromatography-tandem mass spectrometry (LC-MS-MS) method is presented for the qualitative screening for 238 drugs in blood samples, which is considerably more than in previous methods. After a two-step liquid-liquid extraction and C(18) chromatography, the compounds were introduced into a triple quadrupole mass spectrometer equipped with a turbo ion spray ion source operating in the positive ionization mode. Identification was based on the compound's absolute retention time, protonated molecular ion, and one representative fragment ion obtained by multiple reaction monitoring (MRM) at an individually selected collision energy of 20, 35, or 50 eV. The limit of detection (LOD) for the majority of the compounds (80%) was < or = 0.05 mg/l, ranging from 0.002 mg/l (e.g., antihistamines) to 5 mg/l (acidic compounds), and for malathion it was 10 mg/l. The LOD values were sufficiently low to allow the majority of compounds to be detected at therapeutic concentrations in the blood.
Li, Bo; Li, Hao; Dong, Li; Huang, Guofu
2017-11-01
In this study, we sought to investigate the feasibility of fast carotid artery MR angiography (MRA) by combining three-dimensional time-of-flight (3D TOF) with compressed sensing method (CS-3D TOF). A pseudo-sequential phase encoding order was developed for CS-3D TOF to generate hyper-intense vessel and suppress background tissues in under-sampled 3D k-space. Seven healthy volunteers and one patient with carotid artery stenosis were recruited for this study. Five sequential CS-3D TOF scans were implemented at 1, 2, 3, 4 and 5-fold acceleration factors for carotid artery MRA. Blood signal-to-tissue ratio (BTR) values for fully-sampled and under-sampled acquisitions were calculated and compared in seven subjects. Blood area (BA) was measured and compared between fully sampled acquisition and each under-sampled one. There were no significant differences between the fully-sampled dataset and each under-sampled in BTR comparisons (P>0.05 for all comparisons). The carotid vessel BAs measured from the images of CS-3D TOF sequences with 2, 3, 4 and 5-fold acceleration scans were all highly correlated with that of the fully-sampled acquisition. The contrast between blood vessels and background tissues of the images at 2 to 5-fold acceleration is comparable to that of fully sampled images. The images at 2× to 5× exhibit the comparable lumen definition to the corresponding images at 1×. By combining the pseudo-sequential phase encoding order, CS reconstruction, and 3D TOF sequence, this technique provides excellent visualizations for carotid vessel and calcifications in a short scan time. It has the potential to be integrated into current multiple blood contrast imaging protocol. Copyright © 2017. Published by Elsevier Inc.
Morel, Agnieszka; Rywaniak, Joanna; Bijak, Michał; Miller, Elżbieta; Niwald, Marta; Saluk, Joanna
2017-06-01
The epidemiological studies confirm an increased risk of cardiovascular disease in multiple sclerosis, especially prothrombotic events directly associated with abnormal platelet activity. The aim of our study was to investigate the level of blood platelet activation in the circulation of patients with chronic phase of multiple sclerosis (SP MS) and their reactivity in response to typical platelets' physiological agonists. We examined 85 SP MS patients diagnosed according to the revised McDonald's criteria and 50 healthy volunteers as a control group. The platelet activation and reactivity were assessed using flow cytometry analysis of the following: P-selectin expression (CD62P), activation of GP IIb/IIIa complex (PAC-1 binding), and formation of platelet microparticles (PMPs) and platelet aggregates (PA) in agonist-stimulated (ADP, collagen) and unstimulated whole blood samples. Furthermore, we measured the level of soluble P-selectin (sP-selectin) in plasma using ELISA method, to evaluate the in vivo level of platelet activation, both in healthy and SP MS subjects. We found a statistically significant increase in P-selectin expression, GP IIb/IIIa activation, and formation of PMPs and PA, as well as in unstimulated and agonist-stimulated (ADP, collagen) platelets in whole blood samples from patients with SP MS in comparison to the control group. We also determined the higher sP-selectin level in plasma of SP MS subjects than in the control group. Based on the obtained results, we might conclude that during the course of SP MS platelets are chronically activated and display hyperreactivity to physiological agonists, such as ADP or collagen.
2014-01-01
Background Chiari Type I Malformation (CMI) is characterized by herniation of the cerebellar tonsils through the foramen magnum at the base of the skull, resulting in significant neurologic morbidity. As CMI patients display a high degree of clinical variability and multiple mechanisms have been proposed for tonsillar herniation, it is hypothesized that this heterogeneous disorder is due to multiple genetic and environmental factors. The purpose of the present study was to gain a better understanding of what factors contribute to this heterogeneity by using an unsupervised statistical approach to define disease subtypes within a case-only pediatric population. Methods A collection of forty-four pediatric CMI patients were ascertained to identify disease subtypes using whole genome expression profiles generated from patient blood and dura mater tissue samples, and radiological data consisting of posterior fossa (PF) morphometrics. Sparse k-means clustering and an extension to accommodate multiple data sources were used to cluster patients into more homogeneous groups using biological and radiological data both individually and collectively. Results All clustering analyses resulted in the significant identification of patient classes, with the pure biological classes derived from patient blood and dura mater samples demonstrating the strongest evidence. Those patient classes were further characterized by identifying enriched biological pathways, as well as correlated cranial base morphological and clinical traits. Conclusions Our results implicate several strong biological candidates warranting further investigation from the dura expression analysis and also identified a blood gene expression profile corresponding to a global down-regulation in protein synthesis. PMID:24962150
Norris, Laura C; Fornadel, Christen M; Hung, Wei-Chien; Pineda, Fernando J; Norris, Douglas E
2010-07-01
Anopheles arabiensis is a major vector of Plasmodium falciparum in southern Zambia. This study aimed to determine the rate of multiple human blood meals taken by An. arabiensis to more accurately estimate entomologic inoculation rates (EIRs). Mosquitoes were collected in four village areas over two seasons. DNA from human blood meals was extracted and amplified at four microsatellite loci. Using the three-allele method, which counts > or = 3 alleles at any microsatellite locus as a multiple blood meal, we determined that the overall frequency of multiple blood meals was 18.9%, which was higher than rates reported for An. gambiae in Kenya and An. funestus in Tanzania. Computer simulations showed that the three-allele method underestimates the true multiple blood meal proportion by 3-5%. Although P. falciparum infection status was not shown to influence the frequency of multiple blood feeding, the high multiple feeding rate found in this study increased predicted malaria risk by increasing EIR.
Regine, Vincenza; Raimondo, Mariangela; Camoni, Laura; Salfa, Maria Cristina; Gallo, Pietro; Colucci, Anna; Luzi, Anna Maria; Suligoi, Barbara
2013-01-01
Background In Italy, the circulation of human immunodeficiency virus (HIV) has expanded to include population groups that do not perceive themselves to be “at risk” of HIV infection and who do not even consider undergoing HIV testing. The aim of this study was to describe the socio-demographic and behavioural characteristics, and perceived risk of HIV infection in a sample of blood donors who reported never having been tested for HIV. Materials and methods A questionnaire was administered to a sample of donors who called the Italian National AIDS/STI Help Line and reported never having been tested for HIV. Results The study sample consisted of 164 blood donors: 29.3% had given blood in the preceding 2 years. With regards to at-risk behaviours, 39.6% of the donors interviewed were heterosexuals who had sexual contacts with multiple partners, and 5.5% were men who had sex with multiple male partners. Sexual contacts with female sex workers were reported by 11.6% of first-time donors and 25.7% of repeat donors. Of the 164 donors interviewed, 125 (76.2%) said that the main reason that they had never been tested for HIV was that they did not consider themselves at risk. Among these, 56 (44.8%) reported that they would have sexual contacts with a sex worker, 52 (41.6%) reported that they would have sexual contacts with someone having more than one sexual partner, and 36 (28.8%) reported that they would have sexual contacts without using a condom. Discussion All the donors interviewed reported that they had never been tested for HIV despite the fact that they had been certainly been tested upon blood donation. These results show that some sexual behaviours may not be perceived as behaviours at risk for acquiring HIV infection. These findings suggest that not all blood donors are knowledgeable about HIV risk behaviours and that an explicit pre-donation questionnaire and effective counselling continue to be important for the selection of candidate donors. PMID:23736932
Koren, Lee; Ng, Ella S M; Soma, Kiran K; Wynne-Edwards, Katherine E
2012-01-01
Blood samples from wild mammals and birds are often limited in volume, allowing researchers to quantify only one or two steroids from a single sample by immunoassays. In addition, wildlife serum or plasma samples are often lipemic, necessitating stringent sample preparation. Here, we validated sample preparation for simultaneous liquid chromatography--tandem mass spectrometry (LC-MS/MS) quantitation of cortisol, corticosterone, 11-deoxycortisol, dehydroepiandrosterone (DHEA), 17β-estradiol, progesterone, 17α-hydroxyprogesterone and testosterone from diverse mammalian (7 species) and avian (5 species) samples. Using 100 µL of serum or plasma, we quantified (signal-to-noise (S/N) ratio ≥ 10) 4-7 steroids depending on the species and sample, without derivatization. Steroids were extracted from serum or plasma using automated solid-phase extraction where samples were loaded onto C18 columns, washed with water and hexane, and then eluted with ethyl acetate. Quantitation by LC-MS/MS was done in positive ion, multiple reaction-monitoring (MRM) mode with an atmospheric pressure chemical ionization (APCI) source and heated nebulizer (500°C). Deuterated steroids served as internal standards and run time was 15 minutes. Extraction recoveries were 87-101% for the 8 analytes, and all intra- and inter-run CVs were ≤ 8.25%. This quantitation method yields good recoveries with variable lipid-content samples, avoids antibody cross-reactivity issues, and delivers results for multiple steroids. Thus, this method can enrich datasets by providing simultaneous quantitation of multiple steroids, and allow researchers to reimagine the hypotheses that could be tested with their volume-limited, lipemic, wildlife samples.
Stark, Ken D; Aristizabal Henao, Juan J; Metherel, Adam H; Pilote, Louise
2016-01-01
Specific blood levels of eicosapentaenoic plus docosahexaenoic acid (EPA+DHA, wt% of total) in erythrocytes or "the omega-3 index" have been recommended for cardio-protection, but fatty acids are often measured in different blood fractions. The ability to estimate the % of EPA+DHA in erythrocytes from the fatty acid composition of other blood fractions would enable clinical assessments of omega-3 status when erythrocyte fractions are not available and increase the ability to compare blood levels of omega-3 fatty acids across clinical studies. The fatty acid composition of baseline plasma, erythrocytes and whole blood samples from participants (n=1104) in a prospective, multicenter study examining acute coronary syndrome were determined. The ability to predict the % of EPA+DHA in erythrocytes from other blood fractions were examined using bivariate and multiple linear regression modelling. Concordance analysis was also used to compare the actual erythrocytes EPA+DHA values to values estimated from other blood fractions. EPA+DHA in erythrocytes was significantly (p<0.001) correlated EPA+DHA in plasma (r(2)=0.54) and whole blood (r(2)=0.79). Using multiple linear regression to predict EPA+DHA in erythrocytes resulted in stronger coefficients of determination in both plasma (R(2)=0.70) and whole blood (R(2)=0.84). Concordance analyses indicated agreement between actual and estimated EPA+DHA in erythrocytes, although estimating from plasma fatty acids appears to require translation by categorization rather than by translation as continuous data. This study shows that the fatty acid composition of different blood fractions can be used to estimate erythrocyte EPA+DHA in a population with acute coronary syndrome. Copyright © 2015 Elsevier Ltd. All rights reserved.
Chapouly, Candice; Tadesse Argaw, Azeb; Horng, Sam; Castro, Kamilah; Zhang, Jingya; Asp, Linnea; Loo, Hannah; Laitman, Benjamin M; Mariani, John N; Straus Farber, Rebecca; Zaslavsky, Elena; Nudelman, German; Raine, Cedric S; John, Gareth R
2015-06-01
In inflammatory central nervous system conditions such as multiple sclerosis, breakdown of the blood-brain barrier is a key event in lesion pathogenesis, predisposing to oedema, excitotoxicity, and ingress of plasma proteins and inflammatory cells. Recently, we showed that reactive astrocytes drive blood-brain barrier opening, via production of vascular endothelial growth factor A (VEGFA). Here, we now identify thymidine phosphorylase (TYMP; previously known as endothelial cell growth factor 1, ECGF1) as a second key astrocyte-derived permeability factor, which interacts with VEGFA to induce blood-brain barrier disruption. The two are co-induced NFκB1-dependently in human astrocytes by the cytokine interleukin 1 beta (IL1B), and inactivation of Vegfa in vivo potentiates TYMP induction. In human central nervous system microvascular endothelial cells, VEGFA and the TYMP product 2-deoxy-d-ribose cooperatively repress tight junction proteins, driving permeability. Notably, this response represents part of a wider pattern of endothelial plasticity: 2-deoxy-d-ribose and VEGFA produce transcriptional programs encompassing angiogenic and permeability genes, and together regulate a third unique cohort. Functionally, each promotes proliferation and viability, and they cooperatively drive motility and angiogenesis. Importantly, introduction of either into mouse cortex promotes blood-brain barrier breakdown, and together they induce severe barrier disruption. In the multiple sclerosis model experimental autoimmune encephalitis, TYMP and VEGFA co-localize to reactive astrocytes, and correlate with blood-brain barrier permeability. Critically, blockade of either reduces neurologic deficit, blood-brain barrier disruption and pathology, and inhibiting both in combination enhances tissue preservation. Suggesting importance in human disease, TYMP and VEGFA both localize to reactive astrocytes in multiple sclerosis lesion samples. Collectively, these data identify TYMP as an astrocyte-derived permeability factor, and suggest TYMP and VEGFA together promote blood-brain barrier breakdown. © The Author (2015). Published by Oxford University Press on behalf of the Guarantors of Brain. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
21 CFR 880.5965 - Subcutaneous, implanted, intravascular infusion port and catheter.
Code of Federal Regulations, 2014 CFR
2014-04-01
... HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General... and medications and the sampling of blood. The device consists of a portal body with a resealable... device is available in various profiles and sizes and can be of a single or multiple lumen design. (b...
21 CFR 880.5965 - Subcutaneous, implanted, intravascular infusion port and catheter.
Code of Federal Regulations, 2013 CFR
2013-04-01
... HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General... and medications and the sampling of blood. The device consists of a portal body with a resealable... device is available in various profiles and sizes and can be of a single or multiple lumen design. (b...
21 CFR 880.5965 - Subcutaneous, implanted, intravascular infusion port and catheter.
Code of Federal Regulations, 2012 CFR
2012-04-01
... HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General... and medications and the sampling of blood. The device consists of a portal body with a resealable... device is available in various profiles and sizes and can be of a single or multiple lumen design. (b...
Quantitative interpretations of Visible-NIR reflectance spectra of blood.
Serebrennikova, Yulia M; Smith, Jennifer M; Huffman, Debra E; Leparc, German F; García-Rubio, Luis H
2008-10-27
This paper illustrates the implementation of a new theoretical model for rapid quantitative analysis of the Vis-NIR diffuse reflectance spectra of blood cultures. This new model is based on the photon diffusion theory and Mie scattering theory that have been formulated to account for multiple scattering populations and absorptive components. This study stresses the significance of the thorough solution of the scattering and absorption problem in order to accurately resolve for optically relevant parameters of blood culture components. With advantages of being calibration-free and computationally fast, the new model has two basic requirements. First, wavelength-dependent refractive indices of the basic chemical constituents of blood culture components are needed. Second, multi-wavelength measurements or at least the measurements of characteristic wavelengths equal to the degrees of freedom, i.e. number of optically relevant parameters, of blood culture system are required. The blood culture analysis model was tested with a large number of diffuse reflectance spectra of blood culture samples characterized by an extensive range of the relevant parameters.
What Physical Fitness Component Is Most Closely Associated With Adolescents' Blood Pressure?
Nunes, Heloyse E G; Alves, Carlos A S; Gonçalves, Eliane C A; Silva, Diego A S
2017-12-01
This study aimed to determine which of four selected physical fitness variables, would be most associated with blood pressure changes (systolic and diastolic) in a large sample of adolescents. This was a descriptive and cross-sectional, epidemiological study of 1,117 adolescents aged 14-19 years from southern Brazil. Systolic and diastolic blood pressure were measured by a digital pressure device, and the selected physical fitness variables were body composition (body mass index), flexibility (sit-and-reach test), muscle strength/resistance (manual dynamometer), and aerobic fitness (Modified Canadian Aerobic Fitness Test). Simple and multiple linear regression analyses revealed that aerobic fitness and muscle strength/resistance best explained variations in systolic blood pressure for boys (17.3% and 7.4% of variance) and girls (7.4% of variance). Aerobic fitness, body composition, and muscle strength/resistance are all important indicators of blood pressure control, but aerobic fitness was a stronger predictor of systolic blood pressure in boys and of diastolic blood pressure in both sexes.
Sikirzhytskaya, Aliaksandra; Sikirzhytski, Vitali; Lednev, Igor K
2014-01-01
Body fluids are a common and important type of forensic evidence. In particular, the identification of menstrual blood stains is often a key step during the investigation of rape cases. Here, we report on the application of near-infrared Raman microspectroscopy for differentiating menstrual blood from peripheral blood. We observed that the menstrual and peripheral blood samples have similar but distinct Raman spectra. Advanced statistical analysis of the multiple Raman spectra that were automatically (Raman mapping) acquired from the 40 dried blood stains (20 donors for each group) allowed us to build classification model with maximum (100%) sensitivity and specificity. We also demonstrated that despite certain common constituents, menstrual blood can be readily distinguished from vaginal fluid. All of the classification models were verified using cross-validation methods. The proposed method overcomes the problems associated with currently used biochemical methods, which are destructive, time consuming and expensive. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Associations between height and blood pressure in the United States population.
Bourgeois, Brianna; Watts, Krista; Thomas, Diana M; Carmichael, Owen; Hu, Frank B; Heo, Moonseong; Hall, John E; Heymsfield, Steven B
2017-12-01
The mechanisms linking short stature with an increase in cardiovascular and cerebrovascular disease risk remain elusive. This study tested the hypothesis that significant associations are present between height and blood pressure in a representative sample of the US adult population.Participants were 12,988 men and women from a multiethnic sample (age ≥ 18 years) evaluated in the 1999 to 2006 National Health and Nutrition Examination Survey who were not taking antihypertensive medications and who had complete height, weight, % body fat, and systolic and diastolic arterial blood pressure (SBP and DBP) measurements; mean arterial blood pressure and pulse pressure (MBP and PP) were calculated. Multiple regression models for men and women were developed with each blood pressure as dependent variable and height, age, race/ethnicity, body mass index, % body fat, socioeconomic status, activity level, and smoking history as potential independent variables.Greater height was associated with significantly lower SBP and PP, and higher DBP (all P < .001) in combined race/ethnic-sex group models beginning in the 4th decade. Predicted blood pressure differences between people who are short and tall increased thereafter with greater age except for MBP. Socioeconomic status, activity level, and smoking history did not consistently contribute to blood pressure prediction models.Height-associated blood pressure effects were present in US adults who appeared in the 4th decade and increased in magnitude with greater age thereafter. These observations, in the largest and most diverse population sample evaluated to date, provide support for postulated mechanisms linking adult stature with cardiovascular and cerebrovascular disease risk. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.
Rapid Sequencing of Complete env Genes from Primary HIV-1 Samples.
Laird Smith, Melissa; Murrell, Ben; Eren, Kemal; Ignacio, Caroline; Landais, Elise; Weaver, Steven; Phung, Pham; Ludka, Colleen; Hepler, Lance; Caballero, Gemma; Pollner, Tristan; Guo, Yan; Richman, Douglas; Poignard, Pascal; Paxinos, Ellen E; Kosakovsky Pond, Sergei L; Smith, Davey M
2016-07-01
The ability to study rapidly evolving viral populations has been constrained by the read length of next-generation sequencing approaches and the sampling depth of single-genome amplification methods. Here, we develop and characterize a method using Pacific Biosciences' Single Molecule, Real-Time (SMRT®) sequencing technology to sequence multiple, intact full-length human immunodeficiency virus-1 env genes amplified from viral RNA populations circulating in blood, and provide computational tools for analyzing and visualizing these data.
Song, Jiao; Liu, Xuejun; Wu, Jiejun; Meehan, Michael J; Blevitt, Jonathan M; Dorrestein, Pieter C; Milla, Marcos E
2013-02-15
We have developed an ultra-performance liquid chromatography-multiple reaction monitoring/mass spectrometry (UPLC-MRM/MS)-based, high-content, high-throughput platform that enables simultaneous profiling of multiple lipids produced ex vivo in human whole blood (HWB) on treatment with calcium ionophore and its modulation with pharmacological agents. HWB samples were processed in a 96-well plate format compatible with high-throughput sample processing instrumentation. We employed a scheduled MRM (sMRM) method, with a triple-quadrupole mass spectrometer coupled to a UPLC system, to measure absolute amounts of 122 distinct eicosanoids using deuterated internal standards. In a 6.5-min run, we resolved and detected with high sensitivity (lower limit of quantification in the range of 0.4-460 pg) all targeted analytes from a very small HWB sample (2.5 μl). Approximately 90% of the analytes exhibited a dynamic range exceeding 1000. We also developed a tailored software package that dramatically sped up the overall data quantification and analysis process with superior consistency and accuracy. Matrix effects from HWB and precision of the calibration curve were evaluated using this newly developed automation tool. This platform was successfully applied to the global quantification of changes on all 122 eicosanoids in HWB samples from healthy donors in response to calcium ionophore stimulation. Copyright © 2012 Elsevier Inc. All rights reserved.
Morel, Agnieszka; Miller, Elzbieta; Bijak, Michal; Saluk, Joanna
2016-09-01
Platelet activation is increasingly postulated as a possible component of the pathogenesis of multiple sclerosis (MS), especially due to the increased risk of cardiovascular events in MS. Arachidonic acid cascade metabolized by cyclooxygenase (COX) is a key pathway of platelet activation. The aim of our study was to investigate the COX-dependent arachidonic acid metabolic pathway in blood platelets from secondary progressive multiple sclerosis (SP MS) patients. The blood samples were obtained from 50 patients (man n = 22; female n = 28), suffering from SP MS, diagnosed according to the revised McDonald criteria. Platelet aggregation was measured in platelet-rich plasma after arachidonic acid stimulation. The level of COX activity and thromboxane B2 concentration were determined by ELISA method. Lipid peroxidation was assessed by measuring the level of malondialdehyde. The results were compared with a control group of healthy volunteers. We found that blood platelets obtained from SP MS patients were more sensitive to arachidonic acid and their response measured as platelet aggregation was stronger (about 14 %) relative to control. We also observed a significantly increased activity of COX (about 40 %) and synthesis of thromboxane B2 (about 113 %). The generation of malondialdehyde as a marker of lipid peroxidation was about 10 % higher in SP MS than in control. Cyclooxygenase-dependent arachidonic acid metabolism is significantly increased in blood platelets of patients with SP MS. Future clinical studies are required to recommend the use of low-dose aspirin, and possibly other COX inhibitors in the prevention of cardiovascular risk in MS.
Hu, Xiaobin; Zheng, Tongzhang; Cheng, Yibin; Holford, Theodore; Lin, Shaobin; Leaderer, Brian; Qiu, Jie; Bassig, Bryan A; Shi, Kunchong; Zhang, Yawei; Niu, Jianjun; Zhu, Yong; Li, Yonghong; Guo, Huan; Chen, Qiong; Zhang, Jianqing; Xu, Shunqing; Jin, Yinlong
2015-01-01
To measure serum levels of heavy metals in Chinese pregnant women and their newborns, and to evaluate the association of these metals with infant birth weight. We measured serum concentrations of lead (Pb), thallium (Tl), cadmium (Cd), selenium (Se), arsenic (As), nickle (Ni), vanadium (V), cobalt (Co), and mercury (Hg) in 81 mother-infant pairs using an inductively coupled plasma mass spectrometry method. Multiple linear regression analyses were used to evaluate the associations of these heavy metals with infant birth weight. Se, Pb, As, and Cd showed the highest detection rates (98.8%) in both the maternal and cord blood, followed by Tl, which was detected in 79.0% and 71.6% of the maternal and cord blood samples, respectively. Pb had the highest concentrations in both the maternal and cord blood samples of all toxic metals detected, with concentrations of 23.1 ng/g and 22.0 ng/g, respectively. No significant associations were observed between any heavy metals and birth weight. However, Tl in the maternal and cord blood was most notably inversely associated with birth weight. Se intake was low in Chinese women and their newborns, whereas Pb had the highest concentrations in both the maternal and cord blood samples of all toxic metals detected. Tl was a unique pollution source in this population, and Tl levels were shown to have the largest effect on decreasing infant birth weight in this pilot study. Further research incorporating larger sample sizes is needed to investigate the effects of prenatal exposure to heavy metals--especially Tl and Pb--on birth outcome in Chinese infants.
Lunven, Catherine; Turpault, Sandrine; Beyer, Yann-Joel; O'Brien, Amy; Delfolie, Astrid; Boyanova, Neli; Sanderink, Ger-Jan; Baldinetti, Francesca
2016-01-01
Background: Teriflunomide, a once-daily oral immunomodulator approved for treatment of relapsing-remitting multiple sclerosis, is eliminated slowly from plasma. If necessary to rapidly lower plasma concentrations of teriflunomide, an accelerated elimination procedure using cholestyramine or activated charcoal may be used. The current bioanalytical assay for determination of plasma teriflunomide concentration requires laboratory facilities for blood centrifugation and plasma storage. An alternative method, with potential for greater convenience, is dried blood spot (DBS) methodology. Analytical and clinical validations are required to switch from plasma to DBS (finger-prick sampling) methodology. Methods: Using blood samples from healthy subjects, an LC-MS/MS assay method for quantification of teriflunomide in DBS over a range of 0.01–10 mcg/mL was developed and validated for specificity, selectivity, accuracy, precision, reproducibility, and stability. Results were compared with those from the current plasma assay for determination of plasma teriflunomide concentration. Results: Method was specific and selective relative to endogenous compounds, with process efficiency ∼88%, and no matrix effect. Inaccuracy and imprecision for intraday and interday analyses were <15% at all concentrations tested. Quantification of teriflunomide in DBS assay was not affected by blood deposit volume and punch position within spot, and hematocrit level had a limited but acceptable effect on measurement accuracy. Teriflunomide was stable for at least 4 months at room temperature, and for at least 24 hours at 37°C with and without 95% relative humidity, to cover sampling, drying, and shipment conditions in the field. The correlation between DBS and plasma concentrations (R2 = 0.97), with an average blood to plasma ratio of 0.59, was concentration independent and constant over time. Conclusions: DBS sampling is a simple and practical method for monitoring teriflunomide concentrations. PMID:27015245
Kam, Pca; Liou, Jpc; Yang, Kxf
2017-09-01
We evaluated the effects of haemodilution with either dextran 40 or 0.9% normal saline on coagulation in vitro using rotational thromboelastometry (ROTEM®, Pentapharm Co., Munich, Germany) and multiple electrode aggregometry (Multiplate® Platelet Function Analyser, Dynabyte, Munich, Germany). Venous blood samples obtained from 20 healthy volunteers were diluted in vitro with dextran 40 or normal saline by 5%, 10% and 15%. Fibrinogen concentration, ROTEM-EXTEM® (screening test for the extrinsic coagulation pathway), FIBTEM® (an EXTEM-based assay of the fibrin component of clot) parameters including coagulation time, clot formation time, alpha angle, maximum clot firmness and lysis index were measured in the undiluted sample and at each level of haemodilution. Dextran 40 at 15% haemodilution significantly prolonged coagulation time, clot formation time and significantly decreased the alpha angle and maximal clot firmness (EXTEM amplitude at five minutes [A5] and ten minutes [A10]) compared with normal saline. The FIBTEM assay (maximal clot firmness and FIBTEM A5 and A10) showed a marked decrease in maximal clot firmness at all dilutions suggesting impaired fibrinogen activity and a risk of bleeding. Multiple electrode aggregometry did not demonstrate any platelet dysfunction. Haemodilution with dextran 40 causes significant impairment in clot formation and strength compared to saline haemodilution and undiluted blood. At the levels of in vitro haemodilution designed to reflect the clinical use of dextran infusions, no significant fibrinolysis or platelet inhibition was observed.
Blood conservation in neonatal and pediatric populations.
Wilson, J R; Gaedeke, M K
1996-05-01
Blood conservation in infants and children has benefits even beyond those seen with the adult populations. For instance, acquired blood borne diseases such as cytomegalovirus not only cause illness but also can have deleterious effects on the growth and development of infants and children. Decreasing blood transfusions is especially important in preventing sensitization over a lifetime, which may require further transfusion and even organ transplantation. A less striking benefit, but one equally as significant, is decreasing the occurrence of graft-versus-host disease when blood conservation negates the need for multiple transfusions. The limitation of alternative transfusion practices in children and infants increases the benefits of blood conservation. Autologous blood donation may be an alternative to allogeneic transfusion in older children, but is not possible with neonates who may be born anemic and who experience a normal physiologic anemia during the first 2 months of life. Critical care nurses are instrumental in helping blood conservation by understanding blood salvaging techniques, including correct collection techniques, noninvasive monitoring, evaluation of diagnostic sample needs, and administration of erythrocyte-stimulating factors.
Towner, Jonathan S.; Rollin, Pierre E.; Bausch, Daniel G.; Sanchez, Anthony; Crary, Sharon M.; Vincent, Martin; Lee, William F.; Spiropoulou, Christina F.; Ksiazek, Thomas G.; Lukwiya, Mathew; Kaducu, Felix; Downing, Robert; Nichol, Stuart T.
2004-01-01
The largest outbreak on record of Ebola hemorrhagic fever (EHF) occurred in Uganda from August 2000 to January 2001. The outbreak was centered in the Gulu district of northern Uganda, with secondary transmission to other districts. After the initial diagnosis of Sudan ebolavirus by the National Institute for Virology in Johannesburg, South Africa, a temporary diagnostic laboratory was established within the Gulu district at St. Mary's Lacor Hospital. The laboratory used antigen capture and reverse transcription-PCR (RT-PCR) to diagnose Sudan ebolavirus infection in suspect patients. The RT-PCR and antigen-capture diagnostic assays proved very effective for detecting ebolavirus in patient serum, plasma, and whole blood. In samples collected very early in the course of infection, the RT-PCR assay could detect ebolavirus 24 to 48 h prior to detection by antigen capture. More than 1,000 blood samples were collected, with multiple samples obtained from many patients throughout the course of infection. Real-time quantitative RT-PCR was used to determine the viral load in multiple samples from patients with fatal and nonfatal cases, and these data were correlated with the disease outcome. RNA copy levels in patients who died averaged 2 log10 higher than those in patients who survived. Using clinical material from multiple EHF patients, we sequenced the variable region of the glycoprotein. This Sudan ebolavirus strain was not derived from either the earlier Boniface (1976) or Maleo (1979) strain, but it shares a common ancestor with both. Furthermore, both sequence and epidemiologic data are consistent with the outbreak having originated from a single introduction into the human population. PMID:15047846
Block, Gladys; Jensen, Christopher D; Norkus, Edward P; Dalvi, Tapashi B; Wong, Les G; McManus, Jamie F; Hudes, Mark L
2007-01-01
Background Dietary supplement use in the United States is prevalent and represents an important source of nutrition. However, little is known about individuals who routinely consume multiple dietary supplements. This study describes the dietary supplement usage patterns, health, and nutritional status of long-term multiple dietary supplement users, and where possible makes comparisons to non-users and multivitamin/mineral supplement users. Methods Using a cross-sectional study design, information was obtained by online questionnaires and physical examination (fasting blood, blood pressure, body weight) from a convenience sample of long-term users of multiple dietary supplements manufactured by Shaklee Corporation (Multiple Supp users, n = 278). Data for non-users (No Supp users, n = 602) and multivitamin/mineral supplement users (Single Supp users, n = 176) were obtained from the National Health and Nutrition Examination Survey (NHANES) 2001–2002 and NHANES III 1988–1994. Logistic regression methods were used to estimate odds ratios with 95% confidence intervals. Results Dietary supplements consumed on a daily basis by more than 50% of Multiple Supp users included a multivitamin/mineral, B-complex, vitamin C, carotenoids, vitamin E, calcium with vitamin D, omega-3 fatty acids, flavonoids, lecithin, alfalfa, coenzyme Q10 with resveratrol, glucosamine, and a herbal immune supplement. The majority of women also consumed gamma linolenic acid and a probiotic supplement, whereas men also consumed zinc, garlic, saw palmetto, and a soy protein supplement. Serum nutrient concentrations generally increased with increasing dietary supplement use. After adjustment for age, gender, income, education and body mass index, greater degree of supplement use was associated with more favorable concentrations of serum homocysteine, C-reactive protein, high-density lipoprotein cholesterol, and triglycerides, as well as lower risk of prevalent elevated blood pressure and diabetes. Conclusion This group of long-term multiple dietary supplement users consumed a broad array of vitamin/mineral, herbal, and condition-specific dietary supplements on a daily basis. They were more likely to have optimal concentrations of chronic disease-related biomarkers, and less likely to have suboptimal blood nutrient concentrations, elevated blood pressure, and diabetes compared to non-users and multivitamin/mineral users. These findings should be confirmed by studying the dietary supplement usage patterns, health, and nutritional status of other groups of heavy users of dietary supplements. PMID:17958896
Atar, Oliver D; Eisert, Christian; Pokov, Ilya; Serebruany, Victor L
2010-07-01
Sample fixation for storage and/or transportation represents an unsolved challenge for multicenter clinical trials assessing serial changes in platelet activity, or monitoring various antiplatelet regimens. Whole blood flow cytometry represents a major advance in defining platelet function, although special training and expensive equipment is required. We sought to determine how fixation with 2% paraformaldehyde (PFA), and storage of blood samples over 1 week affects the flow cytometry readings for both intact and thrombin-activating four major surface platelet receptors. Whole blood platelet expression of PECAM-1, P-selectin, PAR-1 inactive receptor (SPAN-12), and cleaved (WEDE-15) epitope was assessed immediately after blood draw, after staining with 2% PFA, and at day 1, 3, 5, and 7. The study was performed in 6 volunteers with multiple risk factors for vascular disease, not receiving any antiplatelet agents. Staining with PFA resulted in a slight decrease of fluorescence intensity, especially for PECAM-1, while antigen expression at day 1, 3 and 5 remains consistent, and highly reproducible. At day 7 there was a small but inconsistent trend towards diminished fluorescence intensity. The platelet data were consistent while validated with the isotype-matched irrelevant antibody. These data suggest that there is a 5 day window to perform final flow cytometry readings of whole blood PFA-fixed inactivated platelet samples. In contrast, thrombin activation cause gradual loss of flow cytometry signal, and cannot be recommended for long-term storage. This is critical logistic information for conducting multicenter platelet substudies within the framework of major clinical trials.
The effect of orthostatic stress on multiscale entropy of heart rate and blood pressure.
Turianikova, Zuzana; Javorka, Kamil; Baumert, Mathias; Calkovska, Andrea; Javorka, Michal
2011-09-01
Cardiovascular control acts over multiple time scales, which introduces a significant amount of complexity to heart rate and blood pressure time series. Multiscale entropy (MSE) analysis has been developed to quantify the complexity of a time series over multiple time scales. In previous studies, MSE analyses identified impaired cardiovascular control and increased cardiovascular risk in various pathological conditions. Despite the increasing acceptance of the MSE technique in clinical research, information underpinning the involvement of the autonomic nervous system in the MSE of heart rate and blood pressure is lacking. The objective of this study is to investigate the effect of orthostatic challenge on the MSE of heart rate and blood pressure variability (HRV, BPV) and the correlation between MSE (complexity measures) and traditional linear (time and frequency domain) measures. MSE analysis of HRV and BPV was performed in 28 healthy young subjects on 1000 consecutive heart beats in the supine and standing positions. Sample entropy values were assessed on scales of 1-10. We found that MSE of heart rate and blood pressure signals is sensitive to changes in autonomic balance caused by postural change from the supine to the standing position. The effect of orthostatic challenge on heart rate and blood pressure complexity depended on the time scale under investigation. Entropy values did not correlate with the mean values of heart rate and blood pressure and showed only weak correlations with linear HRV and BPV measures. In conclusion, the MSE analysis of heart rate and blood pressure provides a sensitive tool to detect changes in autonomic balance as induced by postural change.
Pomann, Gina-Maria; Sweeney, Elizabeth M; Reich, Daniel S; Staicu, Ana-Maria; Shinohara, Russell T
2015-09-10
Multiple sclerosis (MS) is an immune-mediated neurological disease that causes morbidity and disability. In patients with MS, the accumulation of lesions in the white matter of the brain is associated with disease progression and worse clinical outcomes. Breakdown of the blood-brain barrier in newer lesions is indicative of more active disease-related processes and is a primary outcome considered in clinical trials of treatments for MS. Such abnormalities in active MS lesions are evaluated in vivo using contrast-enhanced structural MRI, during which patients receive an intravenous infusion of a costly magnetic contrast agent. In some instances, the contrast agents can have toxic effects. Recently, local image regression techniques have been shown to have modest performance for assessing the integrity of the blood-brain barrier based on imaging without contrast agents. These models have centered on the problem of cross-sectional classification in which patients are imaged at a single study visit and pre-contrast images are used to predict post-contrast imaging. In this paper, we extend these methods to incorporate historical imaging information, and we find the proposed model to exhibit improved performance. We further develop scan-stratified case-control sampling techniques that reduce the computational burden of local image regression models, while respecting the low proportion of the brain that exhibits abnormal vascular permeability. Copyright © 2015 John Wiley & Sons, Ltd.
Kurian, S. M.; Williams, A. N.; Gelbart, T.; Campbell, D.; Mondala, T. S.; Head, S. R.; Horvath, S.; Gaber, L.; Thompson, R.; Whisenant, T.; Lin, W.; Langfelder, P.; Robison, E. H.; Schaffer, R. L.; Fisher, J. S.; Friedewald, J.; Flechner, S. M.; Chan, L. K.; Wiseman, A. C.; Shidban, H.; Mendez, R.; Heilman, R.; Abecassis, M. M.; Marsh, C. L.; Salomon, D. R.
2015-01-01
There are no minimally invasive diagnostic metrics for acute kidney transplant rejection (AR), especially in the setting of the common confounding diagnosis, acute dysfunction with no rejection (ADNR). Thus, though kidney transplant biopsies remain the gold standard, they are invasive, have substantial risks, sampling error issues and significant costs and are not suitable for serial monitoring. Global gene expression profiles of 148 peripheral blood samples from transplant patients with excellent function and normal histology (TX; n = 46), AR (n = 63) and ADNR (n = 39), from two independent cohorts were analyzed with DNA microarrays. We applied a new normalization tool, frozen robust multi-array analysis, particularly suitable for clinical diagnostics, multiple prediction tools to discover, refine and validate robust molecular classifiers and we tested a novel one-by-one analysis strategy to model the real clinical application of this test. Multiple three-way classifier tools identified 200 highest value probesets with sensitivity, specificity, positive predictive value, negative predictive value and area under the curve for the validation cohort ranging from 82% to 100%, 76% to 95%, 76% to 95%, 79% to 100%, 84% to 100% and 0.817 to 0.968, respectively. We conclude that peripheral blood gene expression profiling can be used as a minimally invasive tool to accurately reveal TX, AR and ADNR in the setting of acute kidney transplant dysfunction. PMID:24725967
Gebrekidan, Hagos; Gasser, Robin B; Stevenson, Mark A; McGrath, Sean; Jabbar, Abdul
2017-02-01
Oriental theileriosis caused by multiple genotypes of Theileria orientalis is an important tick-borne disease of bovines. Here, we assessed the performance of an established multiplexed tandem PCR (MT-PCR) for the diagnosis of the two recognized, pathogenic genotypes (chitose and ikeda) of T. orientalis in cattle using pooled blood samples. We used a total of 265 cattle blood samples, which were divided into two groups according to previous MT-PCR results for individual samples. Samples in group 1 (n = 155) were from a herd with a relatively high prevalence of T. orientalis infection; and those in group 2 (n = 110) were from four herds with a low prevalence. For group 1, 31 and 15 batches of five- and ten-pooled samples (selected at random), respectively, were formed. For group 2, 22 and 11 batches of five- and ten-pooled samples (selected at random), respectively, were formed. DNAs from individual pooled samples in each batch and group were then tested by MT-PCR. For group 1, the apparent prevalences estimated using the 31 batches of five-pooled samples (97%) and 15 batches of ten-pooled samples (100%) were significantly higher compared with individual samples (75%). For group 2, higher apparent prevalences (9% and 36%) were also recorded for the 22 and 11 batches of pooled samples, respectively, compared with individual samples (7%). Overall, the average infection intensity recorded for the genotypes of chitose and ikeda were considerably lower in pooled compared with individual samples. The diagnostic specificities of MT-PCR were estimated at 95% and 94%, respectively, when batches of five- and ten-pooled samples were tested, and 94% for individual samples. The diagnostic sensitivity of this assay was estimated at 98% same for all individual, five- and ten-pooled samples. This study shows that screening batches of five- and ten-pooled blood samples from cattle herds are similar to those obtained for individual samples, and, importantly, that the reduced cost for the testing of pooled samples represents a considerable saving to herd managers. Copyright © 2016 Elsevier Ltd. All rights reserved.
Rapid Sequencing of Complete env Genes from Primary HIV-1 Samples
Eren, Kemal; Ignacio, Caroline; Landais, Elise; Weaver, Steven; Phung, Pham; Ludka, Colleen; Hepler, Lance; Caballero, Gemma; Pollner, Tristan; Guo, Yan; Richman, Douglas; Poignard, Pascal; Paxinos, Ellen E.; Kosakovsky Pond, Sergei L.
2016-01-01
Abstract The ability to study rapidly evolving viral populations has been constrained by the read length of next-generation sequencing approaches and the sampling depth of single-genome amplification methods. Here, we develop and characterize a method using Pacific Biosciences’ Single Molecule, Real-Time (SMRT®) sequencing technology to sequence multiple, intact full-length human immunodeficiency virus-1 env genes amplified from viral RNA populations circulating in blood, and provide computational tools for analyzing and visualizing these data. PMID:29492273
Zhou, Juhua; Dudley, Mark E.; Rosenberg, Steven A.; Robbins, Paul F.
2007-01-01
Summary The authors recently reported that adoptive immunotherapy with autologous tumor-reactive tumor infiltrating lymphocytes (TILs) immediately following a conditioning nonmyeloablative chemotherapy regimen resulted in an enhanced clinical response rate in patients with metastatic melanoma. These observations led to the current studies, which are focused on a detailed analysis of the T-cell antigen reactivity as well as the in vivo persistence of T cells in melanoma patient 2098, who experienced a complete regression of all metastatic lesions in lungs and soft tissues following therapy. Screening of an autologous tumor cell cDNA library using transferred TILs resulted in the identification of novel mutated growth arrest-specific gene 7 (GAS7) and glyceral-dehyde-3-phosphate dehydrogenase (GAPDH) gene transcripts. Direct sequence analysis of the expressed T-cell receptor beta chain variable regions showed that the transferred TILs contained multiple T-cell clonotypes, at least six of which persisted in peripheral blood for a month or more following transfer. The persistent T cells recognized both the mutated GAS7 and GAPDH. These persistent tumor-reactive T-cell clones were detected in tumor cell samples obtained from the patient following adoptive cell transfer and appeared to be represented at higher levels in the tumor sample obtained 1 month following transfer than in the peripheral blood obtained at the same time. Overall, these results indicate that multiple tumor-reactive T cells can persist in the peripheral blood and at the tumor site for prolonged times following adoptive transfer and thus may be responsible for the complete tumor regression in this patient. PMID:15614045
Wimsatt, J.; O'Shea, T.J.; Ellison, L.E.; Pearce, R.D.; Price, V.R.
2005-01-01
We anesthetized and blood sampled wild big brown bats (Eptesicus fuscus) in Fort Collins, Colorado (USA) in 2001 and 2002 and assessed effects on survival. Inhalant anesthesia was delivered into a specially designed restraint and inhalation capsule that minimized handling and bite exposures. Bats were immobilized an average of 9.1±5.1 (SD) min (range 1–71, n=876); blood sample volumes averaged 58±12 μl (range 13–126, n=718). We randomly selected control (subject to multiple procedures before release) and treatment (control procedures plus inhalant anesthesia and 1% of body weight blood sampling) groups in 2002 to assess treatment effects on daily survival over a 14-day period for adult female and volant juvenile bats captured at maternity roosts in buildings. We monitored survival after release using passive integrated transponder tag detection hoops placed at openings to selected roosts. Annual return rates of bats sampled in 2001 were used to assess long-term outcomes. Comparison of 14-day maximum-likelihood daily survival estimates from control (86 adult females, 92 volant juveniles) and treated bats (187 adult females, 87 volant juveniles) indicated no adverse effect from anesthesia and blood sampling (juveniles: χ2=22.22, df=27, P>0.05; adults: χ2=9.72, df=18, P>0.05). One-year return rates were similar among adult female controls (81%, n=72, 95% confidence interval [CI] =70–91%), females treated once (82%, n=276, 95% CI=81–84%), and females treated twice (84%, n=50, 95% CI=74–94%). Lack of an effect was also noted in 1-yr return rates of juvenile female controls (55%, n=29, 95% CI=37–73%), juveniles treated once (66%, n=113, 95% CI=58–75%), and juveniles treated twice (71%, n=17, 95% CI=49–92%). These data suggest that anesthesia and blood sampling for health monitoring did not measurably affect survival of adult female and volant juvenile big brown bats.
High wavenumber Raman spectroscopic characterization of normal and oral cancer using blood plasma
NASA Astrophysics Data System (ADS)
Pachaiappan, Rekha; Prakasarao, Aruna; Suresh Kumar, Murugesan; Singaravelu, Ganesan
2017-02-01
Blood plasma possesses the biomolecules released from cells/tissues after metabolism and reflects the pathological conditions of the subjects. The analysis of biofluids for disease diagnosis becomes very attractive in the diagnosis of cancers due to the ease in the collection of samples, easy to transport, multiple sampling for regular screening of the disease and being less invasive to the patients. Hence, the intention of this study was to apply near-infrared (NIR) Raman spectroscopy in the high wavenumber (HW) region (2500-3400 cm-1) for the diagnosis of oral malignancy using blood plasma. From the Raman spectra it is observed that the biomolecules protein and lipid played a major role in the discrimination between groups. The diagnostic algorithms based on principal components analysis coupled with linear discriminant analysis (PCA-LDA) with the leave-one-patient-out cross-validation method on HW Raman spectra yielded a promising results in the identification of oral malignancy. The details of results will be discussed.
Mair, B; Drillich, M; Klein-Jöbstl, D; Kanz, P; Borchardt, S; Meyer, L; Schwendenwein, I; Iwersen, M
2016-02-24
Dairy cows have a massive demand for glucose at the onset of lactation. A poor adaption to this period leads to an excessive negative energy balance with an increased risk for ketosis and impaired animal health and production. Besides the measurement of ketones, analysing the glucose concentration in blood is reported as helpful instrument for diagnosis and differentiation of ketosis. Monitoring metabolic parameters requires multiple blood sampling. In other species, new blood sampling techniques have been introduced in which small amounts of blood are rapidly analysed using electronic hand-held devices. The objective of this study was to evaluate the suitability of capillary blood for blood glucose measurement in dairy cows using the hand-held devices FreeStyle Precision (FSP, Abbott), GlucoMen LX Plus (GLX, A. Menarini) and the WellionVet GLUCO CALEA, (WGC, MED TRUST). In total, 240 capillary blood samples were obtained from dry and fresh lactating Holstein-Friesian cows. Blood was collected from the skin of the exterior vulva by using a lancet. For method comparison, additional blood samples were taken from a coccygeal vessel and analyzed in a laboratory. Glucose concentrations measured by a standard laboratory method were defined as the criterion standard. The Pearson correlation coefficients between the glucose concentrations analyzed in capillary blood with the devices and the reference were 73% for the FSP, 81% for the GLX and 41% for the WGC. Bland-Altman plots showed biases of -18.8 mg/dL for the FSP, -11.2 mg/dL for the GLX and +20.82 mg/dL for the WGC. The optimized threshold determined by a Receiver Operating Characteristics analysis to detect hyperglycemia using the FSP was 43 mg/dL with a sensitivity (Se) and specificity (Sp) of 76 and 80%. Using the GLX and WGC optimized thresholds were 49 mg/dL (Se = 92%, Sp = 85%) and 95 mg/dL (Se = 39%, Sp = 92%). The results of this study demonstrate good performance characteristics for the GLX and moderate for the FSP to detect hyperglycemia in dairy cows using capillary blood. With the study settings, the WGC was not suitable for determination of glucose concentrations.
Irace, Concetta; Carallo, Claudio; Scavelli, Faustina; Loprete, Antonio; Merante, Valentina; Gnasso, Agostino
2012-01-01
A direct relationship between blood pressure and viscosity has frequently been reported, although clear data are not available. To better understand the relationship between these two variables, we evaluated blood viscosity and blood pressure in a group of healthy subjects without cardiovascular risk factors. Healthy subjects were selected from participants in a campaign of prevention of cardiovascular disease (n = 103). They underwent blood sampling for measurement of plasma and blood viscosity, haematocrit, blood lipids and glucose. The quantity and distribution of body fat was assessed by body mass index and waist/hip ratio, respectively. Systolic blood pressure (SBP) correlated significantly with age (r = 0.222) and waist/hip ratio (r = 0.374). Diastolic blood pressure (DBP) correlated significantly with waist/hip ratio (r = 0.216), haematocrit (r = 0.333) and blood viscosity (r = 0.258). Multiple linear regression analyses demonstrated that the only variable significantly associated with SBP was age, while haematocrit was the only variable significantly associated with DBP. Blood viscosity was closely related to waist/hip ratio. These findings show that SBP, in healthy subjects, is not influenced by haematocrit and blood viscosity. In contrast, DBP is related to the values of haematocrit. Among classical cardiovascular risk factors, waist/hip ratio is closely related to blood viscosity.
Generation Scotland: Donor DNA Databank; A control DNA resource.
Kerr, Shona M; Liewald, David C M; Campbell, Archie; Taylor, Kerrie; Wild, Sarah H; Newby, David; Turner, Marc; Porteous, David J
2010-11-23
Many medical disorders of public health importance are complex diseases caused by multiple genetic, environmental and lifestyle factors. Recent technological advances have made it possible to analyse the genetic variants that predispose to complex diseases. Reliable detection of these variants requires genome-wide association studies in sufficiently large numbers of cases and controls. This approach is often hampered by difficulties in collecting appropriate control samples. The Generation Scotland: Donor DNA Databank (GS:3D) aims to help solve this problem by providing a resource of control DNA and plasma samples accessible for research. GS:3D participants were recruited from volunteer blood donors attending Scottish National Blood Transfusion Service (SNBTS) clinics across Scotland. All participants gave full written consent for GS:3D to take spare blood from their normal donation. Participants also supplied demographic data by completing a short questionnaire. Over five thousand complete sets of samples, data and consent forms were collected. DNA and plasma were extracted and stored. The data and samples were unlinked from their original SNBTS identifier number. The plasma, DNA and demographic data are available for research. New data obtained from analysis of the resource will be fed back to GS:3D and will be made available to other researchers as appropriate. Recruitment of blood donors is an efficient and cost-effective way of collecting thousands of control samples. Because the collection is large, subsets of controls can be selected, based on age range, gender, and ethnic or geographic origin. The GS:3D resource should reduce time and expense for investigators who would otherwise have had to recruit their own controls.
Micro-array isolation of circulating tumor cells (CTCs): the droplet biopsy chip
NASA Astrophysics Data System (ADS)
Panchapakesan, B.
2017-08-01
We present a new method for circulating tumor cell capture based on micro-array isolation from droplets. Called droplet biopsy, our technique uses a 76-element array of carbon nanotube devices functionalized with anti-EpCAM and antiHer2 antibodies for immunocapture of spiked breast cancer cells in the blood. This droplet biopsy chip can enable capture of CTCs based on both positive and negative selection strategy. Negative selection is achieved through depletion of contaminating leukocytes through the differential settling of blood into layers. We report 55%-100% cancer cell capture yield in this first droplet biopsy chip study. The droplet biopsy is an enabling idea where one can capture CTCs based on multiple biomarkers in a single blood sample.
Impact of Educational Activities in Reducing Pre-Analytical Laboratory Errors
Al-Ghaithi, Hamed; Pathare, Anil; Al-Mamari, Sahimah; Villacrucis, Rodrigo; Fawaz, Naglaa; Alkindi, Salam
2017-01-01
Objectives Pre-analytic errors during diagnostic laboratory investigations can lead to increased patient morbidity and mortality. This study aimed to ascertain the effect of educational nursing activities on the incidence of pre-analytical errors resulting in non-conforming blood samples. Methods This study was conducted between January 2008 and December 2015. All specimens received at the Haematology Laboratory of the Sultan Qaboos University Hospital, Muscat, Oman, during this period were prospectively collected and analysed. Similar data from 2007 were collected retrospectively and used as a baseline for comparison. Non-conforming samples were defined as either clotted samples, haemolysed samples, use of the wrong anticoagulant, insufficient quantities of blood collected, incorrect/lack of labelling on a sample or lack of delivery of a sample in spite of a sample request. From 2008 onwards, multiple educational training activities directed at the hospital nursing staff and nursing students primarily responsible for blood collection were implemented on a regular basis. Results After initiating corrective measures in 2008, a progressive reduction in the percentage of non-conforming samples was observed from 2009 onwards. Despite a 127.84% increase in the total number of specimens received, there was a significant reduction in non-conforming samples from 0.29% in 2007 to 0.07% in 2015, resulting in an improvement of 75.86% (P <0.050). In particular, specimen identification errors decreased by 0.056%, with a 96.55% improvement. Conclusion Targeted educational activities directed primarily towards hospital nursing staff had a positive impact on the quality of laboratory specimens by significantly reducing pre-analytical errors. PMID:29062553
Impact of Educational Activities in Reducing Pre-Analytical Laboratory Errors: A quality initiative.
Al-Ghaithi, Hamed; Pathare, Anil; Al-Mamari, Sahimah; Villacrucis, Rodrigo; Fawaz, Naglaa; Alkindi, Salam
2017-08-01
Pre-analytic errors during diagnostic laboratory investigations can lead to increased patient morbidity and mortality. This study aimed to ascertain the effect of educational nursing activities on the incidence of pre-analytical errors resulting in non-conforming blood samples. This study was conducted between January 2008 and December 2015. All specimens received at the Haematology Laboratory of the Sultan Qaboos University Hospital, Muscat, Oman, during this period were prospectively collected and analysed. Similar data from 2007 were collected retrospectively and used as a baseline for comparison. Non-conforming samples were defined as either clotted samples, haemolysed samples, use of the wrong anticoagulant, insufficient quantities of blood collected, incorrect/lack of labelling on a sample or lack of delivery of a sample in spite of a sample request. From 2008 onwards, multiple educational training activities directed at the hospital nursing staff and nursing students primarily responsible for blood collection were implemented on a regular basis. After initiating corrective measures in 2008, a progressive reduction in the percentage of non-conforming samples was observed from 2009 onwards. Despite a 127.84% increase in the total number of specimens received, there was a significant reduction in non-conforming samples from 0.29% in 2007 to 0.07% in 2015, resulting in an improvement of 75.86% ( P <0.050). In particular, specimen identification errors decreased by 0.056%, with a 96.55% improvement. Targeted educational activities directed primarily towards hospital nursing staff had a positive impact on the quality of laboratory specimens by significantly reducing pre-analytical errors.
Favretto, Donata; Frison, Giampietro; Maietti, Sergio; Ferrara, Santo Davide
2007-07-01
A method has been developed for the simultaneous determination of lysergic acid diethylamide (LSD), its epimer iso-LSD, and its main metabolites nor-LSD and 2-oxo-3-hydroxy LSD in blood, urine, and, for the first time, vitreous humor samples. The method is based on liquid/liquid extraction and liquid chromatography-multiple mass spectrometry detection in an ion trap mass spectrometer, in positive ion electrospray ionization conditions. Five microliter of sample are injected and analysis time is 12 min. The method is specific, selective and sensitive, and achieves limits of quantification of 20 pg/ml for both LSD and nor-LSD in blood, urine, and vitreous humor. No significant interfering substance or ion suppression was identified for LSD, iso-LSD, and nor-LSD. The interassay reproducibilities for LSD at 20 pg/ml and 2 ng/ml in urine were 8.3 and 5.6%, respectively. Within-run precision using control samples at 20 pg/ml and 2 ng/ml was 6.9 and 3.9%. Mean recoveries of two concentrations spiked into drug free samples were in the range 60-107% in blood, 50-105% in urine, and 65-105% in vitreous humor. The method was successfully applied to the forensic determination of postmortem LSD levels in the biological fluids of a multi drug abuser; for the first time, LSD could be detected in vitreous humor.
Plassmann, Merle M; Schmidt, Magdalena; Brack, Werner; Krauss, Martin
2015-09-01
Exposure to environmental pollution and consumer products may result in an uptake of chemicals into human tissues. Several studies have reported the presence of diverse environmental contaminants in human blood samples. However, previously developed multi-target methods for the analysis of human blood include a fairly limited amount of compounds stemming from one or two related compound groups. Thus, the sample preparation method QuEChERS (quick easy cheap effective rugged and safe) was tested for the extraction of 64 analytes covering a broad compound domain followed by detection using liquid and gas chromatography coupled to mass spectrometry (LC- and GC-MS). Forty-seven analytes showed absolute recoveries above 70% in the first QuEChERS step, being a simple liquid-liquid extraction (LLE) using acetonitrile and salt. The second QuEChERS step, being a dispersive solid phase extraction, did not result in an overall improvement of recoveries or removal of background signals. Using solely the LLE step, eight analytes could subsequently be detected in human blood samples from the German Environmental Specimen Bank. Using a LC-multiple reaction monitoring (MRM) method with a triple quadrupole instrument, better recoveries were achieved than with an older LC-high-resolution (HR) MS full scan orbitrap instrument, which required a higher concentration factor of the extracts. However, the application of HRMS full scan methods could be used for the detection of additional compounds retrospectively.
Blood mercury concentrations in CHARGE Study children with and without autism.
Hertz-Picciotto, Irva; Green, Peter G; Delwiche, Lora; Hansen, Robin; Walker, Cheryl; Pessah, Isaac N
2010-01-01
Some authors have reported higher blood mercury (Hg) levels in persons with autism, relative to unaffected controls. We compared blood total Hg concentrations in children with autism or autism spectrum disorder (AU/ASD) and typically developing (TD) controls in population-based samples, and determined the role of fish consumption in differences observed. The Childhood Autism Risk from Genetics and the Environment (CHARGE) Study enrolled children 2-5 years of age. After diagnostic evaluation, we analyzed three groups: AU/ASD, non-AU/ASD with developmental delay (DD), and population-based TD controls. Mothers were interviewed about household, medical, and dietary exposures. Blood Hg was measured by inductively coupled plasma mass spectrometry. Multiple linear regression analysis was conducted (n = 452) to predict blood Hg from diagnostic status controlling for Hg sources. Fish consumption strongly predicted total Hg concentration. AU/ASD children ate less fish. After adjustment for fish and other Hg sources, blood Hg levels in AU/ASD children were similar to those of TD children (p = 0.75); this was also true among non-fish eaters (p = 0.73). The direct effect of AU/ASD diagnosis on blood Hg not through the indirect pathway of altered fish consumption was a 12% reduction. DD children had lower blood Hg concentrations in all analyses. Dental amalgams in children with gum-chewing or teeth-grinding habits predicted higher levels. After accounting for dietary and other differences in Hg exposures, total Hg in blood was neither elevated nor reduced in CHARGE Study preschoolers with AU/ASD compared with unaffected controls, and resembled those of nationally representative samples.
Sirolimus alternative to blood transfusion as a life saver in blue rubber bleb nevus syndrome
Wang, Ke-Ling; Ma, Shu-Fang; Pang, Ling-Yu; Zhang, Meng-Na; Hu, Lin-Yan; Liu, Meng-Jia; Zou, Li-Ping
2018-01-01
Abstract Rationale: Blue rubber bleb nevus syndrome (BRBNS) is a rare disease characterized by multiple venous malformations. The gastrointestinal bleeding and secondary iron deficiency anemia are the most common complications. There are currently no effective treatments for BRBNS. Here, we report a case of successful treatment with a small dose of sirolimus of a BRBN patient with a de novo gene mutation. Patient concerns: A 12-year-old female was admitted to our hospital with multiple hemangiomas for 12 years. The patient often displayed melena; she recently received transfusion of 2 units of red blood cells once every 2 weeks. Multiple fist-sized hemangiomas were piled up on both sides and back of the neck, and were also noted on the arms, legs, chest, back, and on the tip of the tongue. The laboratory findings demonstrated severe anemia. Blood sample sequencing detected a heterozygous de novo mutation c.2545C > Tin the TEK gene. Diagnoses: Based on these findings, final diagnosis of Blue rubber bleb nevus syndrome (BRBNS) was made. Interventions: After the diagnosis, low-dose sirolimus was orally administered. Outcomes: The patient's hemoglobin was increased after treatment with sirolimus for 1 month. Since the initial treatment with sirolimus, she had not received any blood transfusions. The skin and mucosal hemangioma decreased significantly, and new digestive tract hemorrhage, muscle hematoma, or adverse drug reactions were not observed. Lessons: we report a case of a mutation in exon 15 of the TEK gene leading to BRBN. It was successfully treated with a small dose of sirolimus as an alternative to blood transfusion in order to save the of BRBN patient's life. PMID:29465551
Ferguson, Eamonn; Atsma, Femke; de Kort, Wim; Veldhuizen, Ingrid
2012-02-01
Using constructs from the Theory of Planned Behavior and theories of altruism, this article explores how multiple motivations and beliefs for blood donation are clustered and change across the donor career. In so doing important distinctions, for blood donation, between impure altruism, pure altruism, and warm glow are explored. Measures of intentions, cognitive and affective attitudes, role merger, pure altruism, trust, self-efficacy, subjective and moral norms, and habit formation were assessed in a sample of 12,580 whole blood donors. Analyses showed that a distinction between first-time, novice (one to four donations), and experienced donors (five or more donations) is justified. Principal components analysis and confirmatory factor analytic Multiple-Indicator Multiple-Causal models were used to compare models across these groups. A cognition-behavior (CB) factor, including intentions, was common to all groups. First-time and novice donors were marked by a newly identified motivational factor: "reluctant altruism" (i.e., the motivation to donate because of a lack of trust in others). First-time donors exhibited an impure altruism factor whereas for experienced donors warm glow and pure altruism factors were observed. For first-time donors impure altruism and reluctant altruism were both associated with the CB factor in females and impure altruism only in males. For both sexes reluctant altruism was associated of the CB factor in novice donors and warm glow and pure altruism for experienced donors. New avenues for intervention are suggested by the emergence of reluctant altruism for novice donors and warm glow for experienced donors. The importance of distinguishing aspects of altruism is highlighted. © 2012 American Association of Blood Banks.
Wang, Ke-Ling; Ma, Shu-Fang; Pang, Ling-Yu; Zhang, Meng-Na; Hu, Lin-Yan; Liu, Meng-Jia; Zou, Li-Ping
2018-02-01
Blue rubber bleb nevus syndrome (BRBNS) is a rare disease characterized by multiple venous malformations. The gastrointestinal bleeding and secondary iron deficiency anemia are the most common complications. There are currently no effective treatments for BRBNS. Here, we report a case of successful treatment with a small dose of sirolimus of a BRBN patient with a de novo gene mutation. A 12-year-old female was admitted to our hospital with multiple hemangiomas for 12 years. The patient often displayed melena; she recently received transfusion of 2 units of red blood cells once every 2 weeks. Multiple fist-sized hemangiomas were piled up on both sides and back of the neck, and were also noted on the arms, legs, chest, back, and on the tip of the tongue. The laboratory findings demonstrated severe anemia. Blood sample sequencing detected a heterozygous de novo mutation c.2545C > Tin the TEK gene. Based on these findings, final diagnosis of Blue rubber bleb nevus syndrome (BRBNS) was made. After the diagnosis, low-dose sirolimus was orally administered. The patient's hemoglobin was increased after treatment with sirolimus for 1 month. Since the initial treatment with sirolimus, she had not received any blood transfusions. The skin and mucosal hemangioma decreased significantly, and new digestive tract hemorrhage, muscle hematoma, or adverse drug reactions were not observed. we report a case of a mutation in exon 15 of the TEK gene leading to BRBN. It was successfully treated with a small dose of sirolimus as an alternative to blood transfusion in order to save the of BRBN patient's life.
Rossini, Giada; Gaibani, Paolo; Vocale, Caterina; Cagarelli, Roberto; Landini, Maria Paola
2017-09-01
The capability to detect ZIKV RNA is of crucial importance for cases confirmation. However, due to the short-lived viremia, the detection of ZIKV RNA in plasma/serum is challenging for samples collected more than one week after onset of clinical illness. We compared the window time and detection rate of ZIKV RNA in different specimen types (plasma, whole blood and urine) collected simultaneously at several times post-symptom onset. We examined the presence of ZIKV RNA in matched specimens of whole blood, plasma and urine collected in the same date (3-28 days after symptom onset) from 10 ZIKV infected patients. ZIKV RNA was found in plasma as late as 10 days after symptoms onset and tested positive in all 5 (100%) and in 2 of 6 (33,3%) plasma samples collected 1-5 and 6-10 days after symptoms onset, respectively. ZIKV RNA was positive in urine through the 21st day after symptom onset; the detection rate of ZIKV RNA in urine samples was 100% (11/11) for samples collected 1-10 days from symptoms onset, decreasing at later times of sampling. The detection rate of ZIKV RNA in whole blood was comparable to that in urine samples but extended the window of detection of ZIKV RNA up to 26 days after symptom onset. Our results highlight the usefulness of simultaneously testing multiple specimen types in order to extend the rate and the time frame of ZIKV RNA detection, increasing the possibility of cases confirmation through direct diagnosis in convalescence-phase of infection, supplementing serological data which are often difficult to interpret. Copyright © 2017 The British Infection Association. Published by Elsevier Ltd. All rights reserved.
Tanner, Hannah; Evans, Jason T; Gossain, Savita; Hussain, Abid
2017-01-18
Patient mortality is significantly reduced by rapid identification of bacteria from sterile sites. MALDI-TOF can identify bacteria directly from positive blood cultures and multiple sample preparation methods are available. We evaluated three sample preparation methods and two MALDI-TOF score cut-off values. Positive blood culture bottles with organisms present in Gram stains were prospectively analysed by MALDI-TOF. Three lysis reagents (Saponin, SDS, and SepsiTyper lysis bufer) were applied to each positive culture followed by centrifugation, washing and protein extraction steps. Methods were compared using the McNemar test and 16S rDNA sequencing was used to assess discordant results. In 144 monomicrobial cultures, using ≥2.000 as the cut-off value, species level identifications were obtained from 69/144 (48%) samples using Saponin, 86/144 (60%) using SDS, and 91/144 (63%) using SepsiTyper. The difference between SDS and SepsiTyper was not statistically significant (P = 0.228). Differences between Saponin and the other two reagents were significant (P < 0.01). Using ≥1.700 plus top three results matching as the cut-off value, species level identifications were obtained from 100/144 (69%) samples using Saponin, 103/144 (72%) using SDS, and 106/144 (74%) using SepsiTyper and there was no statistical difference between the methods. No true discordances between culture and direct MALDI-TOF identification were observed in monomicrobial cultures. In 32 polymicrobial cultures, MALDI-TOF identified one organism in 34-75% of samples depending on the method. This study demonstrates two inexpensive in-house detergent lysis methods are non-inferior to a commercial kit for analysis of positive blood cultures by direct MALDI-TOF in a clinical diagnostic microbiology laboratory.
Influence of acidic beverage (Coca-Cola) on pharmacokinetics of ibuprofen in healthy rabbits.
Kondal, Amit; Garg, S K
2003-11-01
The study was aimed at determining the effect of Coca-Cola on the pharmacokinetics of ibuprofen in rabbits. In a cross-over study, ibuprofen was given orally in a dose of 56 mg/kg, prepared as 0.5% suspension in carboxymethyl cellulose (CMC) and blood samples (1 ml) were drawn at different time intervals from 0-12 hr. After a washout period of 7 days, Coca-Cola in a dose of (5 ml/kg) was administered along with ibuprofen (56 mg/kg) and blood samples were drawn from 0-12 hr. To these rabbits, 5 ml/kg Coca-Cola was administered once daily for another 7 days. On 8th day, Coca-Cola (5 ml/kg) along with ibuprofen (56 mg/kg), prepared as a suspension was administered and blood samples (1 ml each) were drawn at similar time intervals. Plasma was separated and assayed for ibuprofen by HPLC technique and various pharmacokinetic parameters were calculated. The Cmax and AUC0-alpha of ibuprofen were significantly increased after single and multiple doses of Coca-Cola, thereby indicating increased extent of absorption of ibuprofen. The results warrant the reduction of ibuprofen daily dosage, frequency when administered with Coca-Cola.
Analogous on-axis interference topographic phase microscopy (AOITPM).
Xiu, P; Liu, Q; Zhou, X; Xu, Y; Kuang, C; Liu, X
2018-05-01
The refractive index (RI) of a sample as an endogenous contrast agent plays an important role in transparent live cell imaging. In tomographic phase microscopy (TPM), 3D quantitative RI maps can be reconstructed based on the measured projections of the RI in multiple directions. The resolution of the RI maps not only depends on the numerical aperture of the employed objective lens, but also is determined by the accuracy of the quantitative phase of the sample measured at multiple scanning illumination angles. This paper reports an analogous on-axis interference TPM, where the interference angle between the sample and reference beams is kept constant for projections in multiple directions to improve the accuracy of the phase maps and the resolution of RI tomograms. The system has been validated with both silica beads and red blood cells. Compared with conventional TPM, the proposed system acquires quantitative RI maps with higher resolution (420 nm @λ = 633 nm) and signal-to-noise ratio that can be beneficial for live cell imaging in biomedical applications. © 2018 The Authors Journal of Microscopy © 2018 Royal Microscopical Society.
Ortiz, Genaro Gabriel; Macías-Islas, Miguel Ángel; Pacheco-Moisés, Fermín P.; Cruz-Ramos, José A.; Sustersik, Silvia; Barba, Elías Alejandro; Aguayo, Adriana
2009-01-01
Objective: To determine the oxidative stress markers in serum from patients with relapsing-remitting multiple sclerosis. Methods: Blood samples from healthy controls and 22 patients 15 women (7 aged from 20 to 30 and 8 were > 40 years old) and 7 men (5 aged from 20 to 30 and 2 were > 40 years old) fulfilling the McDonald Criteria and classified as having Relapsing-Remitting Multiple Sclerosis accordingly with Lublin were collected for oxidative stress markers quantification. Results: Nitric oxide metabolites (nitrates/nitrites), lipid peroxidation products (malondialdehyde plus 4-hidroxialkenals), and glutathione peroxidase activity were significantly increased in serum of subjects with relapsing-remitting multiple sclerosis in comparison with that of healthy controls. These data support the hypothesis that multiple sclerosis is a component closely linked to oxidative stress. PMID:19242067
Swaddiwudhipong, Witaya; Tontiwattanasap, Worawit; Khunyotying, Wanlee; Sanreun, Cherd
2013-11-01
We evaluate blood lead levels among Thai children to determine if exposure to lead-acid batteries is associated with elevated blood lead levels (EBLL). We screened 254 children aged 1-14 years old from 2 rural Thai villages for blood lead levels. We also screened 18 of 92 houses in these 2 villages for the presence of environmental lead. The overall prevalence of EBLL (> or = 10 microg/dl) was 43.3% and the mean lead level among study subjects was 9.8 +/- 5.1 microg/dl. The blood lead levels significantly decreased with increasing age. Fifty point eight percent of children who lived in a house with vented lead-acid batteries had EBLL while 23.3% of children who lived in a house without vented lead-acid batteries had EBLL. Multiple logistic regression analysis revealed a significant positive association between the presence of vented lead-acid batteries and EBLL, after adjusting for other variables. Forty-two point nine percent of house floor dust samples collected near the batteries had elevated lead levels, 7.1% of house floor dust samples collected from other areas in the house had elevated lead levels and 0% of the house floor dust samples collected in houses without vented lead-acid batteries had elevated lead levels. In the sampled houses with vented lead-acid batteries, lead contamination was found in the drinking-water kept in household containers, but not in the tap water or other village sources of water. Improper care and placement of vented lead-acid batteries can result in lead contamination in the home environment causing EBLL in exposed children.
Sanders, Alison P.; Flood, Kaye; Chiang, Shu; Herring, Amy H.; Wolf, Leslie; Fry, Rebecca C.
2012-01-01
Exposure to toxic metals during the prenatal period carries the potential for adverse developmental effects to the fetus, yet such exposure remains largely unmonitored in the United States. The aim of this study was to assess maternal exposure to four toxic metals (arsenic (As), cadmium (Cd), mercury (Hg), and lead (Pb)) in a cohort of pregnant women in North Carolina. We analyzed blood samples submitted to the North Carolina Department of Health and Human Services for blood typing to assess toxic metal levels in pregnant women (n = 211) across six North Carolina counties. Whole blood metal concentrations were measured by inductively coupled plasma mass spectrometry. The association between maternal characteristics, including county of residence, age, and race, and metal exposure was analyzed using multiple linear regression analysis. A large fraction of the blood samples showed detectable levels for each of the four metals. Specifically, As (65.7%), Cd (57.3%), Hg (63.8%), and Pb (100%) were detected in blood samples. Moreover, compared with adult females participating in the Fourth National Report on Human Exposure to Environmental Chemicals and guidelines for pregnant women, some women in the sample population exceeded benchmark levels of Cd, Hg, and Pb. Evidence from this pilot study indicates that pregnant women in North Carolina are exposed to As, Cd, Hg, and Pb and suggests that factors related to maternal county of residence and race may impact maternal exposure levels. As increased levels of one or more of these metals in utero have been associated with detrimental developmental and reproductive outcomes, further study is clearly warranted to establish the impacts to newborns. PMID:22427803
Assessing errors in the determination of base excess.
Mentel, Alexander; Bach, Friedhelm; Schüler, Joerg; Herrmann, Walter; Koster, Andreas; Crystal, George J; Gatzounis, Georgios; Mertzlufft, Fritz
2002-05-01
We compared estimates for base excess of extracellular fluid (BE(ecf); mmol/L) obtained in five clinically used blood gas analyzers: AVL Compact 2 (Roche Diagnostics, Mannheim, Germany), Ciba-Corning 860 (Bayer Diagnostics, Fernwald, Germany), IL 1620 (Instrumentation Laboratories, Lexington, MA), Stat Profile Ultra (Nova Biomedical, Waltham, MA), and ABL 510 (Radiometer, Copenhagen, Denmark). A total of 134 measurements per analyzer were obtained in arterial and venous blood samples from 10 patients undergoing cardiac surgery and 65 measurements per analyzer in venous blood samples from 2 healthy volunteers. The blood samples were equilibrated in a tonometer with gases of known composition (37 degrees C). Additional theoretical studies were performed to evaluate the relationship between pH and calculated BE(ecf) value (with varied PCO(2)) using the formulas of the various analyzers. The standard deviations of repeated measurements were 0.24 mmol/L for ABL 510 and approximately 0.45 mmol/L for the other 4 analyzers. The maximal systematic difference between the average of all measurements of each analyzer was 3.7 mmol/L; this was primarily attributable to differences in measuring pH, and, to a lesser extent, to differences in calculation and determination of PCO(2). Comparison of the results from samples with different oxygen saturation showed that the relative alkalinity of deoxygenated hemoglobin (Haldane effect) can also influence the determinations of BE(ecf). A clinically useful way to quantify nonrespiratory disturbances of the acid-base balance is calculation of the base excess of extracellular fluid by using blood gas analyzers. In this study, we found significant variability in estimates of base excess of extracellular fluid obtained with five analyzers from different manufacturers. This variability is attributable to multiple factors, including lack of correction for deoxygenated hemoglobin (Haldane effect).
Hornig, Katlin J; Byers, Stacey R; Callan, Robert J; Holt, Timothy; Field, Megan; Han, Hyungchul
2013-08-01
To compare β-hydroxybutyrate (BHB) and glucose concentrations measured with a dual-purpose point-of-care (POC) meter designed for use in humans and a laboratory biochemical analyzer (LBA) to determine whether the POC meter would be reliable for on-farm measurement of blood glucose and BHB concentrations in sheep in various environmental conditions and nutritional states. 36 pregnant mixed-breed ewes involved in a maternal feed restriction study. Blood samples were collected from each sheep at multiple points throughout gestation and lactation to allow for tracking of gradually increasing metabolic hardship. Whole blood glucose and BHB concentrations were measured with the POC meter and compared with serum results obtained with an LBA. 464 samples were collected. Whole blood BHB concentrations measured with the POC meter compared well with LBA results, and error grid analysis showed the POC values were acceptable. Whole blood glucose concentrations measured with the POC meter had more variation, compared with LBA values, over the glucose ranges evaluated. Results of error grid analysis of POC-measured glucose concentrations were not acceptable, indicating errors likely to result in needless treatment with glucose or other supplemental energy sources in normoglycemic sheep. The POC meter was user-friendly and performed well across a wide range of conditions. The meter was adequate for detection of pregnancy toxemia in sheep via whole blood BHB concentration. Results should be interpreted with caution when the POC meter is used to measure blood glucose concentrations.
Correlation between benzene and testosterone in workers exposed to urban pollution.
Rosati, M V; Sancini, A; Tomei, F; Sacco, C; Traversini, V; De Vita, A; De Cesare, D P; Giammichele, G; De Marco, F; Pagliara, F; Massoni, F; Ricci, L; Tomei, G; Ricci, S
2017-01-01
Many studies have examined the effects of benzene on testosterone. The purpose of this study was to evaluate the possible correlation between the blood levels of benzene and the levels of testosterone. The study involved a group of 148 subjects. For every worker have been made out a blood sample for the evaluation of benzene and testosterone levels and an urine analysis for the evaluation of the levels of trans, trans-muconic acid and S-phenylmercapturic acid. We estimated the Pearson correlation coefficient between the variables in the sample and the urinary metabolites, age, length of service, gender, BMI. For the analysis of the major confounding factors it was performed a multiple linear regression. The Pearson correlation coefficiet showed: 1. a significant inverse correlation between the S-phenyl mercapturic acid and free testosterone; 2. a significant direct correlation between trans-trans muconic acid and BMI. After dividing the sample according to the median of blood benzene (161.0 ng / L), Pearson correlation coefficient showed a significant inverse correlation between the S-phenyl mercapturic acid and free testosterone in the group with values below this median. Our results, to be considered preliminary, suggest that occupational exposure to low levels of benzene, present in urban pollution, affect the blood levels of testosterone. These results need to be confirmed in future studies, with the eventual possibility of including more specific fertility tests.
Chen, Xiabin; Zheng, Xirong; Ding, Kai; Zhou, Ziyuan; Zhan, Chang-Guo; Zheng, Fang
2016-01-01
As new metabolic pathways of cocaine were recently identified, a high performance liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed to simultaneously determine cocaine and nine cocaine-related metabolites in whole blood samples. One-step solid phase extraction was used to extract all of the ten compounds and corresponding internal standards from blood samples. All compounds and internal standards extracted were separated on an Atlantis T3 (100Å, 3 µm, 2.1 mm × 150 mm I.D) column and detected in positive ion and high sensitivity mode with multiple reaction monitoring. This method was validated for its sensitivity, linearity, specificity, accuracy, precision, recovery, and stability. All of the ten compounds were quantifiable ranging from the lower limit of quantification (LLOQs) of ~10 nM (1.9–3.2 ng/ml) to ~1000 nM (190–320 ng/ml) without any interfering substance. Accuracy and precision were determined, and both of them were within the acceptance criteria of the United States (US) Food and Drug Administration (FDA) and European Medicines Agency (EMA) guidelines. The recovery was above 66.7% for all compounds. Stability tests demonstrated the stability of compounds under different storage conditions in whole blood samples. The method was successfully applied to a pharmacokinetic study with co-administration of cocaine and alcohol in rats. PMID:27923200
Boll, Robert; Johnson, Theron; Kaaks, Rudolf; Kühn, Tilman; Skopp, Gisela
2017-09-01
Phosphatidylethanol (PEth), as measured in freshly drawn blood samples, could be a promising new biomarker for habitual alcohol consumption, but it is still unknown whether PEth can also be determined from blood samples having been stored frozen for a longer period. PEth 16:0/18:1 and PEth 18:1/18:1 were determined by LC-MS/MS from red blood cells (RBC) derived from blood samples of (I) 20 healthy volunteers (after 1 month of storage at -80 °C) and (II) 232 participants of the population-based European Prospective Investigation into Cancer and Nutrition (EPIC)-Heidelberg study (after 20 years of storage at -196 °C). Analyses involved liquid-liquid extraction from 100 μl aliquots with phosphatidylpropanol (PProp 18:1/18:1) as the internal standard. Extracts were subjected to a 10-min LC gradient separation, using multiple reaction monitoring of deprotonated molecules for quantification. After 1 month of storage at -80 °C, PEth was detectable in all samples at mean concentrations of 393.6 ± 12.4 ng/ml (PEth 16:0/18:1) and 43.3 ± 1.1 ng/ml (PEth 18:1/18:1). In samples stored for 20 years at -196 °C, PEth was detectable in 23.7% of all samples at mean concentrations of 412.2 ± 655.5 ng/ml (PEth 16:0/18:1) and 38.0 ± 74.8 ng/ml (PEth 18:1/18:1). PEth can be determined reliably from samples of moderate habitual alcohol consumers after 1 month of storage at -80 °C. Our data suggest that PEth is generally also detectable in samples after 20 years of storage at -196 °C. Further studies are needed to assess the still unknown impact of storage duration and temperature on different PEth specimen concentrations.
Liu, Fangwei; Shen, Xubo; Wang, Ruifeng; Yu, Na; Shi, Yongjun; Xiong, Shimin; Xiong, Chengliang; Zhou, Yuanzhong
2018-01-01
Background Both sex hormone-binding globulin and central obesity have been found to be associated with metabolic and cardiovascular diseases. However, the direct relation between sex hormone-binding globulin and central obesity has not been demonstrated. Methodology We performed a cross-sectional study of 1166 male participants from Zunyi, Guizhou, western China, in 2013. Each participant completed a questionnaire and had a brief clinical exam with a fasting blood sample taken. All blood samples underwent standard laboratory testing for sex hormone-binding globulin. Level of serum sex hormone-binding globulin was compared by demographic characteristics, and multiple linear regression was used to evaluate the independent association of variables and sex hormone-binding globulin level. Results The mean serum level of sex hormone-binding globulin was increased in old-aged men (older than 40 years; mean 44.68±20.58 nmol/L), low diastolic blood pressure (<90mmHg; 43.76±20.50 nmol/L), waist-to-height ratio <0.5 (48.73±20.59 nmol/L), no education (52.36±22.91 nmol/L), farm occupation (43.58±20.60nmol/L), non-alcohol or former user (44.78±20.94 nmol/L) and long-term medication history (44.79±21.50 nmol/L). Factors independently associated with sex hormone binding globulin level on multiple regression were waist-to-height ratio (β=- 11.84 [95% confidence interval -13.96,-9.72]), age(β=12.40 [9.63,15.17]) and diastolic blood pressure (β=-5.07 [-7.44,-2.71]). Conclusions Central obesity has an independent inverse relation with serum level of sex hormone binding globulin among western Chinese men.
Schimpf, Karen J.; Meek, Claudia C.; Leff, Richard D.; Phelps, Dale L.; Schmitz, Daniel J.; Cordle, Christopher T.
2015-01-01
Inositol is a six-carbon sugar alcohol and is one of nine biologically significant isomers of hexahydroxycyclohexane. Myo-inositol is the primary biologically active form and is present in higher concentrations in the fetus and newborn than in adults. It is currently being examined for the prevention of retinopathy of prematurity in newborn preterm infants. A robust method for quantifying myo-inositol (MI), D-chiro-inositol (DCI) and 1,5-anhydro-D-sorbitol (ADS) in very small-volume (25 μL) urine, blood serum and/or plasma samples was developed. Using a multiple-column, multiple mobile phase liquid chromatographic system with electrochemical detection, the method was validated with respect to (a) selectivity, (b) accuracy/recovery, (c) precision/reproducibility, (d) sensitivity, (e) stability and (f) ruggedness. The standard curve was linear and ranged from 0.5 to 30 mg/L for each of the three analytes. Above-mentioned performance measures were within acceptable limits described in the Food and Drug Administration’s Guidance for Industry: Bioanalytical Method Validation. The method was validated using blood serum and plasma collected using four common anticoagulants, and also by quantifying the accuracy and sensitivity of MI measured in simulated urine samples recovered from preterm infant diaper systems. The method performs satisfactorily measuring the three most common inositol isomers on 25 μL clinical samples of serum, plasma milk, and/or urine. Similar performance is seen testing larger volume samples of infant formulas and infant formula ingredients. MI, ADS and DCI may be accurately tested in urine samples collected from five different preterm infant diapers if the urine volume is greater than 2–5 mL. PMID:26010453
Some responses of the electric ray (Torpedo marmorata) to low ambient oxygen tensions.
Hughes, G M; Johnston, I A
1978-04-01
I. Blood samples were taken during prolonged hypoxia experiments in which the inspired water oxygen tension was less than 10 mmHg. The oxygen tension of the post-branchial blood was about 5 mmHg and its pH shows a significant lowering from normoxic levels. 2. The decrease in blood pH is correlated with increases in levels of lactate and pyruvate. The lactate/pyruvate ratio increases during hypoxia. 3. An increase in blood succinate was also found, and strongly suggests the accumulation of multiple anaerobic end-products within the tissues. 4. Recovery of normoxic levels of succinate takes place almost immediately following the restart of ventilation whereas the decrease in lactate concentration is slower. 5. It is concluded that these adaptations may be related to the habitat of the fish at low tide in pools where the Po2 may fall very markedly.
Blood analysis by Raman spectroscopy.
Enejder, Annika M K; Koo, Tae-Woong; Oh, Jeankun; Hunter, Martin; Sasic, Slobodan; Feld, Michael S; Horowitz, Gary L
2002-11-15
Concentrations of multiple analytes were simultaneously measured in whole blood with clinical accuracy, without sample processing, using near-infrared Raman spectroscopy. Spectra were acquired with an instrument employing nonimaging optics, designed using Monte Carlo simulations of the influence of light-scattering-absorbing blood cells on the excitation and emission of Raman light in turbid medium. Raman spectra were collected from whole blood drawn from 31 individuals. Quantitative predictions of glucose, urea, total protein, albumin, triglycerides, hematocrit, and hemoglobin were made by means of partial least-squares (PLS) analysis with clinically relevant precision (r(2) values >0.93). The similarity of the features of the PLS calibration spectra to those of the respective analyte spectra illustrates that the predictions are based on molecular information carried by the Raman light. This demonstrates the feasibility of using Raman spectroscopy for quantitative measurements of biomolecular contents in highly light-scattering and absorbing media.
Polski, J M; Kimzey, S; Percival, R W; Grosso, L E
1998-01-01
AIM: To provide a more efficient method for isolating DNA from peripheral blood for use in diagnostic DNA mutation analysis. METHODS: The use of blood impregnated filter paper and Chelex-100 in DNA isolation was evaluated and compared with standard DNA isolation techniques. RESULTS: In polymerase chain reaction (PCR) based assays of five point mutations, identical results were obtained with DNA isolated routinely from peripheral blood and isolated using the filter paper and Chelex-100 method. CONCLUSION: In the clinical setting, this method provides a useful alternative to conventional DNA isolation. It is easily implemented and inexpensive, and provides sufficient, stable DNA for multiple assays. The potential for specimen contamination is reduced because most of the steps are performed in a single microcentrifuge tube. In addition, this method provides for easy storage and transport of samples from the point of acquisition. PMID:9893748
Polski, J M; Kimzey, S; Percival, R W; Grosso, L E
1998-08-01
To provide a more efficient method for isolating DNA from peripheral blood for use in diagnostic DNA mutation analysis. The use of blood impregnated filter paper and Chelex-100 in DNA isolation was evaluated and compared with standard DNA isolation techniques. In polymerase chain reaction (PCR) based assays of five point mutations, identical results were obtained with DNA isolated routinely from peripheral blood and isolated using the filter paper and Chelex-100 method. In the clinical setting, this method provides a useful alternative to conventional DNA isolation. It is easily implemented and inexpensive, and provides sufficient, stable DNA for multiple assays. The potential for specimen contamination is reduced because most of the steps are performed in a single microcentrifuge tube. In addition, this method provides for easy storage and transport of samples from the point of acquisition.
Blood zinc levels in nursing women from different regions of the West Bank of Palestine.
Shawahna, Ramzi; Zyoud, Ahed; Jallad, Donia; Hadwan, Labebah; Ihssan, Neeran; Hilal, Hikmat
2017-07-06
Pregnant and nursing women are at higher risk of zinc deficiency which can have detrimental consequences on health. We assessed blood zinc levels in 72 nursing women from the West Bank of Palestine and investigated the association between sociodemographic variables and blood zinc levels. Blood samples were analyzed for their zinc contents using graphite furnace atomic absorption spectrophotometry. Blood and data collection were performed between July and December 2016. The median blood zinc level was 4.53 mg/L (interquartile range of 0.38 mg/L). In unadjusted analyses, blood zinc levels were higher in nursing women who lived in cities (p-value <.001), had higher household income (p-value <.001), whose husbands had a white collar job (p-value <.05), were nonsmokers (p-value <.05), did not use hair dyes (p-value <.05), and consumed energy beverages (p-value <.001). Multiple linear analysis showed that living in cities and consuming energy beverages remained significantly associated with higher blood zinc levels (p-value <.05). Blood zinc levels were in the range previously reported for similar non-malnourished populations. Nursing women living in cities and those consuming energy beverages tended to have higher blood zinc levels. Urbanized lifestyle might have enhanced blood zinc levels in nursing women.
Terink, Rieneke; Balvers, Michiel G J; Hopman, Maria T; Witkamp, Renger F; Mensink, Marco; Gunnewiek, Jacqueline M T Klein
2017-06-01
Magnesium is essential for optimal sport performance, generating an interest to monitor its status in athletes. However, before measuring magnesium status in blood could become routine, more insight into its diurnal fluctuations and effects of exercise itself is necessary. Therefore, we measured the effect of an acute bout of exercise on ionized (iMg) and total plasma magnesium (tMg) in blood obtained from 18 healthy well-trained endurance athletes (age, 31.1 ± 8.1 yr.; VO 2max , 50.9 ± 7.5 ml/kg/min) at multiple time points, and compared this with a resting situation. At both days, 7 blood samples were taken at set time points (8:30 fasted, 11:00, 12:30, 13:30, 15:00, 16:00, 18:30). The control day was included to correct for a putative diurnal fluctuation of magnesium. During the exercise day, athletes performed a 90 min bicycle ergometer test (70% VO 2max ) between 11:00 and 12:30. Whole blood samples were analyzed for iMg and plasma for tMg concentrations. Both concentrations decreased significantly after exercise (0.52 ± 0.04-0.45 ± 0.03 mmol/L and 0.81 ± 0.07-0.73 ± 0.06 mmol/L, respectively, p < .001) while no significant decline was observed during that time-interval on control days. Both, iMg and tMg, returned to baseline, on average, 2.5 hr after exercise. These findings suggest that timing of blood sampling to analyze Mg status is important. Additional research is needed to establish the recovery time after different types of exercise to come to a general advice regarding the timing of magnesium status assessment in practice.
Dong, Xiaona; Zhang, Yiwei; Meng, Zhiyun; Zhu, Xiaoxia; Gan, Hui; Gu, Ruolan; Wu, Zhuona; Li, Jian; Zheng, Ying; Yang, Baofeng; Dou, Guifang
2018-05-29
HYD-PEP06 is a novel RGD-modified Endostar mimetic peptide with 30 amino acids that is intended to suppress the formation of neoplasm vessels. This assay was developed and validated to monitor the level of the peptide HYD-PEP06 in rat blood, using liquid chromatography tandem mass spectrometry (LC-MS/MS). HYD-PEP10, another peptide similar to the analyte, was used as an internal standard (IS). A triple quadrupole mass spectrometry in Multiple Reaction Monitoring (MRM) mode and an electrospray interface (ESI) in the positive mode were used for MS analysis. The analysis was optimized with addition of 0.3% formic acid (FA) into the mobile phase as well as with a needle washing solution to overcome the carryover effect. In addition, the carryover was reduced by optimizing the mobile phase gradient. Methanol was used as a diluent of working solutions to avoid any adsorption. Methanol:acetonitrile (1:1, v:v) containing 0.3% FA was employed to precipitate the blood samples. Unknown blood samples must be placed in ice bath immediately, and precipitating agents should be added within 30 min to ensure the stability of blood samples. The assay was established and validated. This method showed a good linear relationship for the HYD-PEP06 in the range of 10 ng·mL -1 to 2000 ng·mL -1 , with R > 0.99. HYD-PEP06 was determined with accuracy values (RE%) of -5.06%-8.54%, intra- and inter-day precisions (RSD%) of 3.13%-4.87% and 4.81%-9.42%. The method was successfully in monitoring the concentration of HYD-PEP06 in rat blood. Copyright © 2018 Elsevier B.V. All rights reserved.
Laserson, K F; Petralanda, I; Hamlin, D M; Almera, R; Fuentes, M; Carrasquel, A; Barker, R H
1994-02-01
We have examined the reproducibility, sensitivity, and specificity of detecting Plasmodium falciparum using the polymerase chain reaction (PCR) and the species-specific probe pPF14 under field conditions in the Venezuelan Amazon. Up to eight samples were field collected from each of 48 consenting Amerindians presenting with symptoms of malaria. Sample processing and analysis was performed at the Centro Amazonico para la Investigacion y Control de Enfermedades Tropicales Simon Bolivar. A total of 229 samples from 48 patients were analyzed by PCR methods using four different P. falciparum-specific probes. One P. vivax-specific probe and by conventional microscopy. Samples in which results from PCR and microscopy differed were reanalyzed at a higher sensitivity by microscopy. Results suggest that microscopy-negative, PCR-positive samples are true positives, and that microscopy-positive and PCR-negative samples are true negatives. The sensitivity of the DNA probe/PCR method was 78% and its specificity was 97%. The positive predictive value of the PCR method was 88%, and the negative predictive value was 95%. Through the analysis of multiple blood samples from each individual, the DNA probe/PCR methodology was found to have an inherent reproducibility that was highly statistically significant.
Jarvi, Susan I; Pitt, William C; Farias, Margaret E; Shiels, Laura; Severino, Michael G; Howe, Kathleen M; Jacquier, Steven H; Shiels, Aaron B; Amano, Karis K; Luiz, Blaine C; Maher, Daisy E; Allison, Maureen L; Holtquist, Zachariah C; Scheibelhut, Neil T
2015-01-01
The nematode Angiostrongylus cantonensis is a rat lungworm, a zoonotic pathogen that causes human eosinophilic meningitis and ocular angiostrongyliasis characteristic of rat lungworm (RLW) disease. Definitive diagnosis is made by finding and identifying A. cantonensis larvae in the cerebral spinal fluid or by using a custom immunological or molecular test. This study was conducted to determine if genomic DNA from A. cantonensis is detectable by qPCR in the blood or tissues of experimentally infected rats. F1 offspring from wild rats were subjected to experimental infection with RLW larvae isolated from slugs, then blood or tissue samples were collected over multiple time points. Blood samples were collected from 21 rats throughout the course of two trials (15 rats in Trial I, and 6 rats in Trial II). In addition to a control group, each trial had two treatment groups: the rats in the low dose (LD) group were infected by approximately 10 larvae and the rats in the high dose (HD) group were infected with approximately 50 larvae. In Trial I, parasite DNA was detected in cardiac bleed samples from five of five LD rats and five of five HD rats at six weeks post-infection (PI), and three of five LD rats and five of five HD rats from tail tissue. In Trial II, parasite DNA was detected in peripheral blood samples from one of two HD rats at 53 minutes PI, one of two LD rats at 1.5 hours PI, one of two HD rats at 18 hours PI, one of two LD rats at five weeks PI and two of two at six weeks PI, and two of two HD rats at weeks five and six PI. These data demonstrate that parasite DNA can be detected in peripheral blood at various time points throughout RLW infection in rats.
Kalliokoski, Otto; Sørensen, Dorte B; Hau, Jann; Abelson, Klas S P
2014-01-01
Facial vein (cheek blood) and caudal vein (tail blood) phlebotomy are two commonly used techniques for obtaining blood samples from laboratory mice, while automated blood sampling through a permanent catheter is a relatively new technique in mice. The present study compared physiological parameters, glucocorticoid dynamics as well as the behavior of mice sampled repeatedly for 24 h by cheek blood, tail blood or automated blood sampling from the carotid artery. Mice subjected to cheek blood sampling lost significantly more body weight, had elevated levels of plasma corticosterone, excreted more fecal corticosterone metabolites, and expressed more anxious behavior than did the mice of the other groups. Plasma corticosterone levels of mice subjected to tail blood sampling were also elevated, although less significantly. Mice subjected to automated blood sampling were less affected with regard to the parameters measured, and expressed less anxious behavior. We conclude that repeated blood sampling by automated blood sampling and from the tail vein is less stressful than cheek blood sampling. The choice between automated blood sampling and tail blood sampling should be based on the study requirements, the resources of the laboratory and skills of the staff. PMID:24958546
Stamler, Jeremiah; Brown, Ian J; Yap, Ivan K S; Chan, Queenie; Wijeyesekera, Anisha; Garcia-Perez, Isabel; Chadeau-Hyam, Marc; Ebbels, Timothy M D; De Iorio, Maria; Posma, Joram; Daviglus, Martha L; Carnethon, Mercedes; Holmes, Elaine; Nicholson, Jeremy K; Elliott, Paul
2013-12-01
Black compared with non-Hispanic white Americans have higher systolic and diastolic blood pressure and rates of prehypertension/hypertension. Reasons for these adverse findings remain obscure. Analyses here focused on relations of foods/nutrients/urinary metabolites and higher black blood pressure for 369 black compared with 1190 non-Hispanic white Americans aged 40 to 59 years from 8 population samples. Multiple linear regression, standardized data from four 24-hour dietary recalls per person, two 24-hour urine collections, and 8 blood pressure measurements were used to quantitate the role of foods, nutrients, and metabolites in higher black blood pressure. Compared with non-Hispanic white Americans, blacks' average systolic/diastolic pressure was higher by 4.7/3.4 mm Hg (men) and 9.0/4.8 mm Hg (women). Control for higher body mass index of black women reduced excess black systolic/diastolic pressure to 6.8/3.8 mm Hg. Lesser intake of vegetables, fruits, grains, vegetable protein, glutamic acid, starch, fiber, minerals, and potassium, and higher intake of processed meats, pork, eggs, and sugar-sweetened beverages, along with higher cholesterol and higher Na/K ratio, related to in higher black blood pressure. Control for 11 nutrient and 10 non-nutrient correlates reduced higher black systolic/diastolic pressure to 2.3/2.3 mm Hg (52% and 33% reduction in men) and to 5.3/2.8 mm Hg (21% and 27% reduction in women). Control for foods/urinary metabolites had little further influence on higher black blood pressure. Less favorable multiple nutrient intake by blacks than non-Hispanic white Americans accounted, at least in part, for higher black blood pressure. Improved dietary patterns can contribute to prevention/control of more adverse black blood pressure levels.
Does chronic warfarin cause increased blood loss and transfusion during lumbar spinal surgery?
Young, Ernest Y; Ahmadinia, Kasra; Bajwa, Navkirat; Ahn, Nicholas U
2013-10-01
The use of oral anticoagulation therapy such as warfarin is projected to increase significantly as the population ages and the prevalence of cardiovascular disease increases. Current recommendations state that warfarin be discontinued before surgery and the international normalized ratio (INR) normalized. To determine if stopping warfarin 7 days before surgery and correcting INR had any effect on intraoperative blood loss or the requirements for blood product transfusion. This was a retrospective cohort study in a high-volume tertiary care center. Sample comprised 263 consecutive patients who underwent elective lumbar spinal surgery. The outcome measures were intraoperative blood loss, intraoperative blood transfusion, postoperative blood transfusion, and the number of blood products transfused. The records of patients undergoing elective spinal surgery were analyzed for patient demographic data, comorbidities, coagulation panel laboratory findings, operative characteristics, blood loss, and blood transfusion requirements. These included patients undergoing full laminectomies with or without posterolateral fusion and instrumentation. Patients on warfarin were analyzed for the mean dosage of warfarin and underlying pathology that required anticoagulation. All patients on warfarin had their anticoagulation therapy stopped 7 days before surgery and their INR checked preoperatively to confirm normalization. Both univariate and multiple linear regression analyses were performed. The patients on warfarin had a mean intraoperative blood loss of 839 mL compared with 441 mL for patients not on warfarin (p<.01). Multiple regression analysis determined that warfarin and number of spinal levels decompressed/fused/instrumented were predictors for increased blood loss (R(2)=0.37). Patients on warfarin also had increased postoperative blood transfusions (23.1% compared with 7.4%, p=.04). There was no significant difference between groups in terms of intraoperative blood transfusion or number of units transfused. Patients on chronic anticoagulation therapy with warfarin who have their therapy stopped 7 days before surgery and have their INR normalized still demonstrated increased intraoperative blood loss and requirement for postoperative transfusion. Surgeons should be aware of the increased propensity of these patients to bleed despite adherence to protocols and should attempt to mitigate this risk. Copyright © 2013 Elsevier Inc. All rights reserved.
Epstein Barr Virus and Blood Brain Barrier in Multiple Sclerosis
2013-07-01
Distribution Unlimited 13. SUPPLEMENTARY NOTES 14. ABSTRACT Multiple sclerosis (MS) is a chronic, autoimmune neurodegenerative disease . Epstein - Barr ...of EBV in MS disease . 15. SUBJECT TERMS Blood-brain-barrier, Epstein - Barr virus ; EBV; BBB; MS, Multiple sclerosis 16. SECURITY CLASSIFICATION OF...AD_________________ Award Number: W81XWH-12-1-0225 TITLE: Epstein Barr virus and blood brain
Taylor, Rachel R.; Hoffman, Keith L.; Schniedewind, Björn; Clavijo, Claudia; Galinkin, Jeffrey L.; Christians, Uwe
2013-01-01
Acetaminophen (paracetamol, N-(4-hydroxyphenyl) acetamide) is one of the most commonly prescribed drugs for the management of pain in children. Quantification of acetaminophen in pre-term and term neonates and small children requires the availability of highly sensitive assays in small volume blood samples. We developed and validated an LC-MS/MS assay for the quantification of acetaminophen in human plasma, cerebro-spinal fluid (CSF) and dried blood spots (DBS). Reconstitution in water (DBS only) and addition of a protein precipitation solution containing the deuterated internal standard were the only manual steps. Extracted samples were analyzed on a Kinetex 2.6 μm PFP column using an acetonitrile/formic acid gradient. The analytes were detected in the positive multiple reaction mode. Alternatively, DBS were automatically processed using direct desorption in a sample card and preparation (SCAP) robotic autosampler in combination with online extraction. The range of reliable response in plasma and CSF was 3.05-20,000 ng/ml (r2 > 0.99) and 27.4-20,000 ng/ml (r2 > 0.99) for DBS (manual extraction and automated direct desorption). Inter-day accuracy was always within 85-115% and inter-day precision for plasma, CSF and manually extracted DBS were less than 15%. Deming regression analysis comparing 167 matching pairs of plasma and DBS samples showed a correlation coefficient of 0.98. Bland Altman analysis indicated a 26.6% positive bias in DBS, most likely reflecting the blood: plasma distribution ratio of acetaminophen. DBS are a valid matrix for acetaminophen pharmacokinetic studies. PMID:23670126
Abend, M; Badie, C; Quintens, R; Kriehuber, R; Manning, G; Macaeva, E; Njima, M; Oskamp, D; Strunz, S; Moertl, S; Doucha-Senf, S; Dahlke, S; Menzel, J; Port, M
2016-02-01
The risk of a large-scale event leading to acute radiation exposure necessitates the development of high-throughput methods for providing rapid individual dose estimates. Our work addresses three goals, which align with the directive of the European Union's Realizing the European Network of Biodosimetry project (EU-RENB): 1. To examine the suitability of different gene expression platforms for biodosimetry purposes; 2. To perform this examination using blood samples collected from prostate cancer patients (in vivo) and from healthy donors (in vitro); and 3. To compare radiation-induced gene expression changes of the in vivo with in vitro blood samples. For the in vitro part of this study, EDTA-treated whole blood was irradiated immediately after venipuncture using single X-ray doses (1 Gy/min(-1) dose rate, 100 keV). Blood samples used to generate calibration curves as well as 10 coded (blinded) samples (0-4 Gy dose range) were incubated for 24 h in vitro, lysed and shipped on wet ice. For the in vivo part of the study PAXgene tubes were used and peripheral blood (2.5 ml) was collected from prostate cancer patients before and 24 h after the first fractionated 2 Gy dose of localized radiotherapy to the pelvis [linear accelerator (LINAC), 580 MU/min, exposure 1-1.5 min]. Assays were run in each laboratory according to locally established protocols using either microarray platforms (2 laboratories) or qRT-PCR (2 laboratories). Report times on dose estimates were documented. The mean absolute difference of estimated doses relative to the true doses (Gy) were calculated. Doses were also merged into binary categories reflecting aspects of clinical/diagnostic relevance. For the in vitro part of the study, the earliest report time on dose estimates was 7 h for qRT-PCR and 35 h for microarrays. Methodological variance of gene expression measurements (CV ≤10% for technical replicates) and interindividual variance (≤twofold for all genes) were low. Dose estimates based on one gene, ferredoxin reductase (FDXR), using qRT-PCR were as precise as dose estimates based on multiple genes using microarrays, but the precision decreased at doses ≥2 Gy. Binary dose categories comprising, for example, unexposed compared with exposed samples, could be completely discriminated with most of our methods. Exposed prostate cancer blood samples (n = 4) could be completely discriminated from unexposed blood samples (n = 4, P < 0.03, two-sided Fisher's exact test) without individual controls. This could be performed by introducing an in vitro-to-in vivo correction factor of FDXR, which varied among the laboratories. After that the in vitro-constructed calibration curves could be used for dose estimation of the in vivo exposed prostate cancer blood samples within an accuracy window of ±0.5 Gy in both contributing qRT-PCR laboratories. In conclusion, early and precise dose estimates can be performed, in particular at doses ≤2 Gy in vitro. Blood samples of prostate cancer patients exposed to 0.09-0.017 Gy could be completely discriminated from pre-exposure blood samples with the doses successfully estimated using adjusted in vitro-constructed calibration curves.
Long-term Blood Pressure Measurement in Freely Moving Mice Using Telemetry.
Alam, Mohammad Afaque; Parks, Cory; Mancarella, Salvatore
2016-05-17
During the development of new vasoactive agents, arterial blood pressure monitoring is crucial for evaluating the efficacy of the new proposed drugs. Indeed, research focusing on the discovery of new potential therapeutic targets using genetically altered mice requires a reliable, long-term assessment of the systemic arterial pressure variation. Currently, the gold standard for obtaining long-term measurements of blood pressure in ambulatory mice uses implantable radio-transmitters, which require artery cannulation. This technique eliminates the need for tethering, restraining, or anesthetizing the animals which introduce stress and artifacts during data sampling. However, arterial blood pressure monitoring in mice via catheterization can be rather challenging due to the small size of the arteries. Here we present a step-by-step guide to illustrate the crucial key passages for a successful subcutaneous implantation of radio-transmitters and carotid artery cannulation in mice. We also include examples of long-term blood pressure activity taken from freely moving mice after a period of post-surgery recovery. Following this procedure will allow reliable direct blood pressure recordings from multiple animals simultaneously.
Evidence-based point-of-care tests and device designs for disaster preparedness.
Brock, T Keith; Mecozzi, Daniel M; Sumner, Stephanie; Kost, Gerald J
2010-01-01
To define pathogen tests and device specifications needed for emerging point-of-care (POC) technologies used in disasters. Surveys included multiple-choice and ranking questions. Multiple-choice questions were analyzed with the chi2 test for goodness-of-fit and the binomial distribution test. Rankings were scored and compared using analysis of variance and Tukey's multiple comparison test. Disaster care experts on the editorial boards of the American Journal of Disaster Medicine and the Disaster Medicine and Public Health Preparedness, and the readers of the POC Journal. Vibrio cholera and Staphylococcus aureus were top-ranked pathogens for testing in disaster settings. Respondents felt that disaster response teams should be equipped with pandemic infectious disease tests for novel 2009 H1N1 and avian H5N1 influenza (disaster care, p < 0.05; POC, p < 0.01). In disaster settings, respondents preferred self-contained test cassettes (disaster care, p < 0.05; POC, p < 0.001) for direct blood sampling (POC, p < 0.01) and disposal of biological waste (disaster care, p < 0.05; POC, p < 0.001). Multiplex testing performed at the POC was preferred in urgent care and emergency room settings. Evidence-based needs assessment identifies pathogen detection priorities in disaster care scenarios, in which Vibrio cholera, methicillin-sensitive and methicillin-resistant Staphylococcus aureus, and Escherichia coli ranked the highest. POC testing should incorporate setting-specific design criteria such as safe disposable cassettes and direct blood sampling at the site of care.
Automated processing of whole blood samples into microliter aliquots of plasma.
Burtis, C A; Johnson, W W; Walker, W A
1988-01-01
A rotor that accepts and automatically processes a bulk aliquot of a single blood sample into multiple aliquots of plasma has been designed and built. The rotor consists of a central processing unit, which includes a disk containing eight precision-bore capillaries. By varying the internal diameters of the capillaries, aliquot volumes ranging 1 to 10 mul can be prepared. In practice, an unmeasured volume of blood is placed in a centre well, and, as the rotor begins to spin, is moved radially into a central annular ring where it is distributed into a series of processing chambers. The rotor is then spun at 3000 rpm for 10 min. When the centrifugal field is removed by slowly decreasing the rotor speed, an aliquot of plasma is withdrawn by capillary action into each of the capillary tubes. The disk containing the eight measured aliquots of plasma is subsequently removed and placed in a modifed rotor for conventional centrifugal analysis. Initial evaluation of the new rotor indicates that it is capable of producing discrete, microliter volumes of plasma with a degree of accuracy and precision approaching that of mechanical pipettes.
Work related stress and blood glucose levels.
Sancini, A; Ricci, S; Tomei, F; Sacco, C; Pacchiarotti, A; Nardone, N; Ricci, P; Suppi, A; De Cesare, D P; Anzelmo, V; Giubilati, R; Pimpinella, B; Rosati, M V; Tomei, G
2017-01-01
The aim of the study is to evaluate work-related subjective stress in a group of workers on a major Italian company in the field of healthcare through the administration of a valid "questionnaire-tool indicator" (HSE Indicator Tool), and to analyze any correlation between stress levels taken from questionnaire scores and blood glucose values. We studied a final sample consisting of 241 subjects with different tasks. The HSE questionnaire - made up of 35 items (divided into 7 organizational dimensions) with 5 possible answers - has been distributed to all the subjects in occasion of the health surveillance examinations provided by law. The questionnaire was then analyzed using its specific software to process the results related to the 7 dimensions. These results were compared using the Pearson correlation and multiple linear regression with the blood glucose values obtained from each subject. From the analysis of the data the following areas resulted critical, in other words linked to an intermediate (yellow area) or high (red area) condition of stress: sustain from managers, sustain from colleagues, quality of relationships and professional changes. A significant positive correlation (p <0.05) between the mean values of all critical areas and the concentrations of glucose values have been highlighted with the correlation index of Pearson. Multiple linear regression confirmed these findings, showing that the critical dimensions resulting from the questionnaire were the significant variables that can increase the levels of blood glucose. The preliminary results indicate that perceived work stress can be statistically associated with increased levels of blood glucose.
The Indian Council of Medical Research–India Diabetes (ICMR–INDIAB) Study: Methodological Details
Anjana, Ranjit Mohan; Pradeepa, Rajendra; Deepa, Mohan; Datta, Manjula; Sudha, Vasudevan; Unnikrishnan, Ranjit; Nath, Lalith M; Das, Ashok Kumar; Madhu, Sri Venkata; Rao, Paturi Vishnupriya; Shukla, Deepak Kumar; Kaur, Tanvir; Ali, Mohammed K; Mohan, Viswanathan
2011-01-01
Background Currently available estimates of diabetes prevalence in India are based on published data derived from very few studies. The Indian Council of Medical Research–India Diabetes (ICMR–INDIAB) study is a community-based survey conceived with the aim of obtaining the prevalence rates of diabetes in India as a whole, covering all 28 states, the National Capital Territory of Delhi, and two of the union territories in the mainland of India, with a total sample size of 124,000 individuals. Methods A stratified multistage sampling design has been used. In all study subjects, a structured questionnaire was administered and anthropometric parameters and blood pressure were measured. Fasting capillary blood glucose was first determined using a glucose meter. An oral glucose load was then administered to all subjects except those with self-reported diabetes, and the 2 h post-load capillary blood glucose was estimated. In every fifth subject, a fasting venous sample was collected for measurement of lipids and creatinine, a resting 12-lead electrocardiogram was performed, and dietary assessment questionnaire was administered. In all diabetic subjects, an additional diabetes questionnaire was used and a fasting venous sample drawn for glycated hemoglobin. Results All biological samples collected were analyzed in a central laboratory. All data collected were stored electronically. Quality control was achieved through multiple tiers of checks. Conclusions The ICMR–INDIAB study is the first of its kind attempting to provide accurate and comprehensive state- and national-level data on diabetes prevalence in India. PMID:21880233
Kuračka, Lubomír; Kalnovičová, Terézia; Kucharská, Jarmila; Turčáni, Peter
2014-01-01
In the pathogenesis of demyelinating diseases including multiple sclerosis (MS) an important role is played by oxidative stress. Increased energy requirements during remyelination of axons and mitochondria failure is one of the causes of axonal degeneration and disability in MS. In this context, we analyzed to what extent the increase in purine catabolism is associated with selected blood lipophilic antioxidants and if there is any association with alterations in serum levels of coenzyme Q10. Blood serum and cerebrospinal fluid (CSF) samples from 42 patients with diagnosed MS and 34 noninflammatory neurologic patients (control group) were analyzed. Compared to control group, MS patients had significantly elevated values of all purine nucleotide metabolites, except adenosine. Serum lipophilic antioxidants γ -tocopherol, β -carotene, and coenzyme Q10 for the vast majority of MS patients were deficient or moved within the border of lower physiological values. Serum levels of TBARS, marker of lipid peroxidation, were increased by 81% in the MS patients. The results indicate that the deficit of lipophilic antioxidants in blood of MS patients may have a negative impact on bioenergetics of reparative remyelinating processes and promote neurodegeneration.
Factors associated with arterial stiffness in children aged 9-10 years
Batista, Milena Santos; Mill, José Geraldo; Pereira, Taisa Sabrina Silva; Fernandes, Carolina Dadalto Rocha; Molina, Maria del Carmen Bisi
2015-01-01
OBJECTIVE To analyze the factors associated with stiffness of the great arteries in prepubertal children. METHODS This study with convenience sample of 231 schoolchildren aged 9-10 years enrolled in public and private schools in Vitória, ES, Southeastern Brazil, in 2010-2011. Anthropometric and hemodynamic data, blood pressure, and pulse wave velocity in the carotid-femoral segment were obtained. Data on current and previous health conditions were obtained by questionnaire and notes on the child’s health card. Multiple linear regression was applied to identify the partial and total contribution of the factors in determining the pulse wave velocity values. RESULTS Among the students, 50.2% were female and 55.4% were 10 years old. Among those classified in the last tertile of pulse wave velocity, 60.0% were overweight, with higher mean blood pressure, waist circumference, and waist-to-height ratio. Birth weight was not associated with pulse wave velocity. After multiple linear regression analysis, body mass index (BMI) and diastolic blood pressure remained in the model. CONCLUSIONS BMI was the most important factor in determining arterial stiffness in children aged 9-10 years. PMID:25902563
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shi, Tujin; Zhou, Jianying; Gritsenko, Marina A.
2012-02-01
Interest in the application of advanced proteomics technologies to human blood plasma- or serum-based clinical samples for the purpose of discovering disease biomarkers continues to grow; however, the enormous dynamic range of protein concentrations in these types of samples (often >10 orders of magnitude) represents a significant analytical challenge, particularly for detecting low-abundance candidate biomarkers. In response, immunoaffinity separation methods for depleting multiple high- and moderate-abundance proteins have become key tools for enriching low-abundance proteins and enhancing detection of these proteins in plasma proteomics. Herein, we describe IgY14 and tandem IgY14-Supermix separation methods for removing 14 high-abundance and up tomore » 60 moderate-abundance proteins, respectively, from human blood plasma and highlight their utility when combined with liquid chromatography-tandem mass spectrometry for interrogating the human plasma proteome.« less
Keytsman, Charly; Hansen, Dominique; Wens, Inez; O Eijnde, Bert
2017-10-27
High-intensity concurrent training positively affects cardiovascular risk factors. Because this was never investigated in multiple sclerosis, the present pilot study explored the impact of this training on cardiovascular risk factors in this population. Before and after 12 weeks of high-intense concurrent training (interval and strength training, 5 sessions per 2 weeks, n = 16) body composition, resting blood pressure and heart rate, 2-h oral glucose tolerance (insulin sensitivity, glycosylated hemoglobin, blood glucose and insulin concentrations), blood lipids (high- and low-density lipoprotein, total cholesterol, triglyceride levels) and C-reactive protein were analyzed. Twelve weeks of high-intense concurrent training significantly improved resting heart rate (-6%), 2-h blood glucose concentrations (-13%) and insulin sensitivity (-24%). Blood pressure, body composition, blood lipids and C-reactive protein did not seem to be affected. Under the conditions of this pilot study, 12 weeks of concurrent high-intense interval and strength training improved resting heart rate, 2-h glucose and insulin sensitivity in multiple sclerosis but did not affect blood C-reactive protein levels, blood pressure, body composition and blood lipid profiles. Further, larger and controlled research investigating the effects of high-intense concurrent training on cardiovascular risk factors in multiple sclerosis is warranted. Implications for rehabilitation High-intensity concurrent training improves cardiovascular fitness. This pilot study explores the impact of this training on cardiovascular risk factors in multiple sclerosis. Despite the lack of a control group, high-intense concurrent training does not seem to improve cardiovascular risk factors in multiple sclerosis.
A versatile electrophoresis-based self-test platform.
Staal, Steven; Ungerer, Mathijn; Floris, Arjan; Ten Brinke, Hans-Willem; Helmhout, Roy; Tellegen, Marian; Janssen, Kjeld; Karstens, Erik; van Arragon, Charlotte; Lenk, Stefan; Staijen, Erik; Bartholomew, Jody; Krabbe, Hans; Movig, Kris; Dubský, Pavel; van den Berg, Albert; Eijkel, Jan
2015-03-01
This paper reports on recent research creating a family of electrophoresis-based point of care devices for the determination of a wide range of ionic analytes in various sample matrices. These devices are based on a first version for the point-of-care measurement of Li(+), reported in 2010 by Floris et al. (Lab Chip 2010, 10, 1799-1806). With respect to this device, significant improvements in accuracy, precision, detection limit, and reliability have been obtained especially by the use of multiple injections of one sample on a single chip and integrated data analysis. Internal and external validation by clinical laboratories for the determination of analytes in real patients by a self-test is reported. For Li(+) in blood better precision than the standard clinical determination for Li(+) was achieved. For Na(+) in human urine the method was found to be within the clinical acceptability limits. In a veterinary application, Ca(2+) and Mg(2+) were determined in bovine blood by means of the same chip, but using a different platform. Finally, promising preliminary results are reported with the Medimate platform for the determination of creatinine in whole blood and quantification of both cations and anions through replicate measurements on the same sample with the same chip. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Ewing, Michael A; Huntley, Samuel R; Baker, Dustin K; Smith, Kenneth S; Hudson, Parke W; McGwin, Gerald; Ponce, Brent A; Johnson, Michael D
2018-04-01
Total ankle arthroplasty (TAA) is an increasingly used, effective treatment for end-stage ankle arthritis. Although numerous studies have associated blood transfusion with complications following hip and knee arthroplasty, its effects following TAA are largely unknown. This study uses data from a large, nationally representative database to estimate the association between blood transfusion and inpatient complications and hospital costs following TAA. Using the Nationwide Inpatient Sample (NIS) database from 2004 to 2014, 25 412 patients who underwent TAA were identified, with 286 (1.1%) receiving a blood transfusion. Univariate analysis assessed patient and hospital factors associated with blood transfusion following TAA. Patients requiring blood transfusion were more likely to be female, African American, Medicare recipients, and treated in nonteaching hospitals. Average length of stay for patients following transfusion was 3.0 days longer, while average inpatient cost was increased by approximately 50%. Patients who received blood transfusion were significantly more likely to suffer from congestive heart failure, peripheral vascular disease, hypothyroidism, coagulation disorder, or anemia. Acute renal failure was significantly more common among patients receiving blood transfusion ( P < .001). Blood transfusions following TAA are infrequent and are associated with multiple medical comorbidities, increased complications, longer hospital stays, and increased overall cost. Level III: Retrospective, comparative study.
Relationship between maternal sodium intake and blood lead concentration during pregnancy.
Lee, Yo A; Hwang, Ji-Yun; Kim, Hyesook; Kim, Ki Nam; Ha, Eun-Hee; Park, Hyesook; Ha, Mina; Kim, Yangho; Hong, Yun-Chul; Chang, Namsoo
2013-03-14
Pb is released from bone stores during pregnancy, which constitutes a period of increased bone resorption. A high Na intake has been found to be negatively associated with Ca and adversely associated with bone metabolism. It is possible that a high Na intake during pregnancy increases the blood Pb concentration; however, no previous study has reported on the relationship between Na intake and blood Pb concentration. We thus have investigated this relationship between Na intake and blood Pb concentrations, and examined whether this relationship differs with Ca intake in pregnant Korean women. Blood Pb concentrations were analysed in 1090 pregnant women at mid-pregnancy. Dietary intakes during mid-pregnancy were estimated by a 24 h recall method covering the use of dietary supplements. Blood Pb concentrations in whole-blood samples were analysed using graphite furnace atomic absorption spectrophotometry. Multiple regression analysis performed after adjustment for covariates revealed that maternal Na intake was positively associated with blood Pb concentration during pregnancy, but only when Ca intake was below the estimated average requirement for pregnant Korean women (P= 0·001). The findings of the present study suggest that blood Pb concentration during pregnancy could be minimised by dietary recommendations that include decreased Na and increased Ca intakes.
The relation of maternal blood arsenic to anemia during pregnancy.
Vigeh, Mohsen; Yokoyama, Kazuhito; Matsukawa, Takehisa; Shinohara, Atsuko; Ohtani, Katsumi
2015-01-01
To clarify the relationship of prenatal arsenic exposure to hemoglobin concentrations and anemia during pregnancy, a longitudinal study was conducted of 364 participants during early pregnancy from October 2006 to March 2011 in Tehran, Iran. Maternal whole blood (taken between 8-12 and 20-24 weeks of gestation, and at delivery) and umbilical cord blood samples were collected for arsenic measurement. The mean concentration of maternal blood arsenic in the first trimester of pregnancy was significantly lower in anemic women compared with non-anemic participants (mean ± SD: 12.4 ± 3.4 versus 14.8 ± 4.0 μg/L, respectively, p < 0.001). Maternal whole blood arsenic levels in the first and third trimesters were significantly (p < 0.05) correlated with hemoglobin concentrations measured throughout gestation (r = 0.312, 0.424, and 0.183). Multiple logistic regression analysis demonstrated that increased maternal blood arsenic levels in the first trimester were significantly negatively associated to anemia during pregnancy (OR = 0.85, CI: 0.77-0.94, p < 0.01). The present study showed that prenatal blood arsenic exposure was not a risk factor for the occurrence of anemia.
Sims, Regina; Madhere, Serge; Callender, Clive; Campbell, Alfonso
2013-01-01
Objective The association between cardiovascular disease (CVD) risk and neurocognitive function has gathered a good deal of attention in the health and social science literature; however, the relationship among several CVD risk factors and neurocognitive function has not been fully explored in an African American sample. The purpose of this study was to examine the pattern of relationships among four CVD risk factors and five measures of higher cortical functions. Methods Data were collected from a sample of 106 African American community-dwelling adults in the metropolitan Washington, DC, area. A nurse collected blood pressure, waist circumference, and a blood sample (to assess triglycerides and high-density lipoprotein (HDL) cholesterol) from study participants. Participants completed the Symbol Digit Modalities Test, Trailmaking B, Stroop Colorword Task, California Verbal Learning Test-II, and Wisconsin Card Sorting Test as assessments of neurocognitive function. Canonical analysis and multiple regression analysis were the major statistical methods utilized to assess relationships between CVD risk factors and neurocognitive function. Results The results suggest that 1) attentional processes are associated with diastolic blood pressure levels, 2) verbal learning processes are associated with diastolic blood pressure and triglyceride levels, and 3) the ability to shift cognitive set is associated with HDL cholesterol levels. Conclusion As cardiovascular health worsens in our society, particularly among ethnic minorities, the neurocognitive consequences must be clearly understood. Future studies should focus on identifying and building awareness of cardiovascular and neurocognitive links through longitudinal research designs and brain imaging technology. PMID:19157252
The polonium-210 poisoning of Mr Alexander Litvinenko
Harrison, John; Fell, Tim; Leggett, Rich; ...
2017-02-28
Mr Litvinenko died on 23rd November 2006 after having been poisoned with polonium-210 on 1st November. Measurements of the polonium-210 content of post-mortem tissue samples and samples of urine and blood showed the presence of large amounts of 210Po. Furthermore, autoradiography of hair samples showed two regions of 210Po activity, providing evidence of an earlier poisoning attempt during October 2006, resulting in absorption to blood of about one-hundredth of that estimated for 1st November. Intake by ingestion on 1st November was estimated to be around 4 GBq, assuming 10% absorption to blood, and the resulting organ doses reached estimatedmore » values that were generally in a range from about 20 Gy to over 100 Gy. In comparison with estimates of protracted alpha particle the doses required to cause irreversible organ damage support the conclusion that death was the inevitable consequence of multiple organ failure, with destruction of the haemopoietic bone marrow, as well as damage to kidneys and liver, being important contributors. If the earlier poisoning during October 2006 had not been followed by a second major intake on 1st November, it is possible that the earlier intake of around 40 MBq, with absorption of 4 MBq to blood, might have proved fatal over a prolonged period of months or years, primarily as a result of kidney damage following a dose of approaching 3 Gy.« less
The polonium-210 poisoning of Mr Alexander Litvinenko
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harrison, John; Fell, Tim; Leggett, Rich
Mr Litvinenko died on 23rd November 2006 after having been poisoned with polonium-210 on 1st November. Measurements of the polonium-210 content of post-mortem tissue samples and samples of urine and blood showed the presence of large amounts of 210Po. Furthermore, autoradiography of hair samples showed two regions of 210Po activity, providing evidence of an earlier poisoning attempt during October 2006, resulting in absorption to blood of about one-hundredth of that estimated for 1st November. Intake by ingestion on 1st November was estimated to be around 4 GBq, assuming 10% absorption to blood, and the resulting organ doses reached estimatedmore » values that were generally in a range from about 20 Gy to over 100 Gy. In comparison with estimates of protracted alpha particle the doses required to cause irreversible organ damage support the conclusion that death was the inevitable consequence of multiple organ failure, with destruction of the haemopoietic bone marrow, as well as damage to kidneys and liver, being important contributors. If the earlier poisoning during October 2006 had not been followed by a second major intake on 1st November, it is possible that the earlier intake of around 40 MBq, with absorption of 4 MBq to blood, might have proved fatal over a prolonged period of months or years, primarily as a result of kidney damage following a dose of approaching 3 Gy.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baghurst, P.A.; McMichael, A.J.; Wigg, N.R.
1992-10-29
Exposure to lead in early childhood is thought to result in delayed neuropsychological development. As yet there is little longitudinal evidence to establish whether these effects persist into later childhood. The authors measured IQ scores in 494 seven-year-old children from the lead-smelting community of Port Pirie, Australia, in whom developmental deficits associated with elevated blood lead concentrations had already been reported at the ages of two and four years. Exposure to lead was estimated from the lead concentrations in maternal blood samples drawn antenatally and at delivery and from blood samples drawn from the children at birth (umbilical-cord blood), atmore » the ages of 6 and 15 months and 2 years, and annually thereafter. Data relating to known covariates of child development were collected systematically for each child throughout the first seven years of life. The authors found inverse relations between IQ at the age of seven years and both antenatal and postnatal blood lead concentrations. After adjustment by multiple regression for sex, parents' level of education, maternal age at delivery, parents' smoking status, socioeconomic status, quality of the home environment, maternal IQ, birth weight, birth order, feeding method (breast, bottle, or both), duration of breast-feeding, and whether the child's natural parents were living together, the relation with lead exposure was still evident for postnatal blood samples, particularly within the age range of 15 months to 4 years. For an increase in blood lead concentration from 10 micrograms per deciliter (0.48 mumol per liter) to 30 micrograms per deciliter (1.45 mumol per liter), expressed as the average of the concentrations at 15 months and 2, 3, and 4 years, the estimated reduction in the IQ of the children was in the range of 4.4 points (95 percent confidence interval, 2.2 to 6.6) to 5.3 points (95 percent confidence interval, 2.8 to 7.8).« less
Broad-Range 16S rDNA PCR on Heart Valves in Infective Endocarditis.
Müller Premru, Manica; Lejko Zupanc, Tatjana; Klokočovnik, Tomislav; Ruzić Sabljić, Eva; Cerar, Tjaša
2016-03-01
Infective endocarditis (IE) is diagnosed by blood and/or resected valve cultivation and echocardiographic findings, as defined by the Duke criteria. Unfortunately, cultures may be negative due to prior antibiotic therapy or fastidious or slow-growing microorganisms. The study aim was to investigate the value of the broad-range polymerase chain reaction (PCR) in addition to blood and valve culture for the detection of causative microorganisms. Between February 2012 and March 2015, valve samples from 36 patients undergoing cardiac surgery were analyzed; of these patients, 26 had a preoperative diagnosis of IE and 10 served as controls. Multiple blood cultures were obtained from 34 patients before antibiotic therapy was commenced. Valve samples were inoculated on bacteriological media and underwent analysis using broad-range PCR (16S rDNA). IE was confirmed microbiologically in 21 of the 26 patients (80.7%); in 20 cases (76.9%) this was by positive blood cultures and in 16 (61.5%) by positive valves. Valves were positive in 15 blood culturepositive patients, and in one blood-culture negative patient. Broad-range PCR detected a microorganism in valves significantly more frequently (n = 14; 53.8%) compared to valve culture (n = 8; 30.7%) (chisquare 11.5, p <0.001). The predominant microorganisms were Staphylococcus aureus, Streptococcus of the viridans group, coagulasenegative staphylococci and Enterococcus faecalis. Blood, valve cultures and broad-range PCR were negative in five patients (19.3%) with IE, and in all 10 subjects of the control group. Broad-range PCR on valves was more sensitive than valve culture. However, blood culture, if taken before the start of antibiotic therapy, was the best method for detecting IE.
Rakanović-Todić, Maida; Burnazović-Ristić, Lejla; Ibrulj, Slavka; Mulbegović, Nedžad
2014-05-01
Endogenious opiod met-enkephalin throughout previous research manifested cytoprotective and anti-inflammatory effects. Previous research suggests that met-enkephalin has cytogenetic effects. Reducement in the frequency of structural chromosome aberrations as well as a suppressive effect on lymphocyte cell cycle is found. It also reduces apoptosis in the blood samples of the patients with immune-mediated diseases. Met-enkephalin exerts immunomodulatory properties and induces stabilization of the clinical condition in patients with multiple Sclerosis (MS). The goal of the present research was to evaluate met-enkephalin in vitro effects on the number and type of chromosome aberrations in the peripheral blood lymphocytes of patients with MS. Our research detected disappearance of ring chromosomes and chromosome fragmentations in the cultures of the peripheral blood lymphocytes treated with met-enkephalin (1.2 μg/mL). However, this research did not detect any significant effects of met-enkephalin on the reduction of structural chromosome aberrations and disappearance of dicentric chromosomes. Chromosomes with the greatest percent of inclusion in chromosome aberrations were noted as: chromosome 1, chromosome 2 and chromosome 9. Additionally, we confirmed chromosome 14 as the most frequently included in translocations. Furthermore, met-enkephalin effects on the increase of the numerical aberrations in both concentrations applied were detected. Those findings should be interpreted cautiously and more research in this field should be conducted.
NASA Astrophysics Data System (ADS)
Darvin, Maxim E.; Magnussen, Björn; Lademann, Juergen; Köcher, Wolfgang
2016-09-01
Non-invasive measurement of carotenoid antioxidants in human skin is one of the important tasks to investigate the skin physiology in vivo. Resonance Raman spectroscopy and reflection spectroscopy are the most frequently used non-invasive techniques in dermatology and skin physiology. In the present study, an improved method based on multiple spatially resolved reflection spectroscopy (MSRRS) was introduced. The results obtained were compared with those obtained using the ‘gold standard’ resonance Raman spectroscopy method and showed strong correlations for the total carotenoid concentration (R = 0.83) as well as for lycopene (R = 0.80). The measurement stability was confirmed to be better than 10% within the total temperature range from 5 °C to + 30 °C and pressure contact between the skin and the MSRRS sensor from 800 Pa to 18 000 Pa. In addition, blood samples taken from the subjects were analyzed for carotenoid concentrations. The MSRRS sensor was calibrated on the blood carotenoid concentrations resulting in being able to predict with a correlation of R = 0.79. On the basis of blood carotenoids it could be demonstrated that the MSRRS cutaneous measurements are not influenced by Fitzpatrick skin types I-VI. The MSRRS sensor is commercially available under the brand name biozoom.
Combinatorial Screening Of Inorganic And Organometallic Materials
Li, Yi , Li, Jing , Britton, Ted W.
2002-06-25
A method for differentiating and enumerating nucleated red blood cells in a blood sample is described. The method includes the steps of lysing red blood cells of a blood sample with a lytic reagent, measuring nucleated blood cells by DC impedance measurement in a non-focused flow aperture, differentiating nucleated red blood cells from other cell types, and reporting nucleated red blood cells in the blood sample. The method further includes subtracting nucleated red blood cells and other interference materials from the count of remaining blood cells, and reporting a corrected white blood cell count of the blood sample. Additionally, the method further includes measuring spectrophotometric absorbance of the sample mixture at a predetermined wavelength of a hemoglobin chromogen formed upon lysing the blood sample, and reporting hemoglobin concentration of the blood sample.
Zhang, Guang Lan; Keskin, Derin B.; Lin, Hsin-Nan; Lin, Hong Huang; DeLuca, David S.; Leppanen, Scott; Milford, Edgar L.; Reinherz, Ellis L.; Brusic, Vladimir
2014-01-01
Human leukocyte antigens (HLA) are important biomarkers because multiple diseases, drug toxicity, and vaccine responses reveal strong HLA associations. Current clinical HLA typing is an elimination process requiring serial testing. We present an alternative in situ synthesized DNA-based microarray method that contains hundreds of thousands of probes representing a complete overlapping set covering 1,610 clinically relevant HLA class I alleles accompanied by computational tools for assigning HLA type to 4-digit resolution. Our proof-of-concept experiment included 21 blood samples, 18 cell lines, and multiple controls. The method is accurate, robust, and amenable to automation. Typing errors were restricted to homozygous samples or those with very closely related alleles from the same locus, but readily resolved by targeted DNA sequencing validation of flagged samples. High-throughput HLA typing technologies that are effective, yet inexpensive, can be used to analyze the world’s populations, benefiting both global public health and personalized health care. PMID:25505899
Brumbaugh, W.G.; Schmitt, C.J.; May, T.W.
2005-01-01
The Tri-States Mining District (TSMD) of Missouri (MO), Kansas (KS), and Oklahoma (OK), USA, was mined for lead (Pb) and zinc (Zn) for more than a century. Mining ceased more than 30 years ago, but wastes remain widely distributed in the region, and there is evidence of surface- and groundwater contamination in the Spring River-Neosho River (SR-NR) system of northeastern OK. In October 2001, we collected a total of 74 fish from six locations in the SR-NR system that included common carp (Cyprinus carpio), channel- and flathead catfish (Ictalurus punctatus and Pylodictis olivaris), largemouth- and spotted bass (Micropterus salmoides and Micropterus punctulatus), and white crappie (Pomoxis annularis). We obtained additional fish from locations in MO that included three reference sites and one site that served as a "positive control" (heavily contaminated by Pb). Blood, carcass (headed, eviscerated, and scaled) and liver (carp only) samples were analyzed for cadmium (Cd), Pb, and Zn. Our objectives were to assess the degree to which fish from the OK portion of the SR-NR system are contaminated by these elements and to evaluate fish blood sampling for biomonitoring. Concentrations of Cd and Pb in carp and catfish from OK sites were elevated and Pb concentrations of some approached those of the highly contaminated site in MO, but concentrations in bass and crappie were relatively low. For Zn, correlations were weak among concentrations in the three tissues and none of the samples appeared to reflect site contamination. Variability was high for Cd in all three tissues of carp; differences between sites were statistically significant (p < 0.05) only for blood even though mean liver concentrations were at least 100-fold greater than those in blood. Blood concentrations of Cd and Pb were positively correlated (r 2 = 0.49 to 0.84) with the concentration of the same element in carp and catfish carcasses or in carp livers, and the corresponding multiple regression models were highly significant (p < 0.001). Our data indicate that potentially nonlethal blood sampling can be useful for monitoring of selected metals in carp, catfish, and perhaps other fishes. ?? 2005 Springer Science+Business Media, Inc.
Mitchell, Thomas A; Herzig, Maryanne C; Fedyk, Chriselda G; Salhanick, Marc A; Henderson, Aaron T; Parida, Bijaya K; Prat, Nicolas J; Dent, Daniel L; Schwacha, Martin G; Cap, Andrew P
2017-06-01
Autotransfusion of shed blood from traumatic hemothorax is an attractive option for resuscitation of trauma patients in austere environments. However, previous analyses revealed that shed hemothorax (HX) blood is defibrinated, thrombocytopenic, and contains elevated levels of D-dimer. Mixing studies with normal pooled plasma demonstrated hypercoagulability, evoking concern for potentiation of acute traumatic coagulopathy. We hypothesized that induction of coagulopathic changes by shed HX blood may be due to increases in cellular microparticles (MP) and that these may also affect recipient platelet function. Shed HX blood was obtained from 17 adult trauma patients under an Institutional Review Board approved prospective observational protocol. Blood samples were collected every hour up to 4 h after thoracostomy tube placement. The corresponding plasma was isolated and frozen for analysis. The effects of shed HX frozen plasma (HFP) and isolated HX microparticles (HMP) on coagulation and platelet function were assessed through mixing studies with platelet-rich plasma at various dilutions followed by analysis with thromboelastometry (ROTEM), platelet aggregometry (Multiplate), enzyme-linked immunosorbent assays, and flow cytometry. Furthermore, HFP was assessed for von Willebrand factor antigen levels and multimer content, and plasma-free hemoglobin. ROTEM analysis demonstrated that diluted HFP and isolated HMP samples decreased clotting time, clotting formation time, and increased α angle, irrespective of sample concentrations, when compared with diluted control plasma. Isolated HMP inhibited platelet aggregation in response to adenosine diphosphate, arachidonic acid, and collagen. HFP contained elevated levels of fibrin-degradation products and tissue factor compared with control fresh frozen plasma samples. MP concentrations in HFP were significantly increased and enriched in events positive for phosphatidylserine, tissue factor, CD235, CD45, CD41a, and CD14. von Willebrand factor (vWF) multimer analysis revealed significant loss of high molecular weight multimers in HFP samples. Plasma-free hemoglobin levels were 8-fold higher in HFP compared with fresh frozen plasma. HFP induces plasma hypercoagulability that is likely related to increased tissue factor and phosphatidylserine expression originating from cell-derived MP. In contrast, platelet dysfunction is induced by HMP, potentially aggravated by depletion of high molecular weight multimers of vWF. Thus, autologous transfusion of shed traumatic hemothorax blood may induce a range of undesirable effects in patients with acute traumatic coagulopathy.
Analysis of evolutionary rate of HIV-1 subtype B using blood donor samples in Japan.
Shinohara, Naoya; Matsumoto, Chieko; Matsubayashi, Keiji; Nagai, Tadashi; Satake, Masahiro
2018-06-01
There are few reports on HIV-1 intra-host evolutionary rate in asymptomatic treatment-naïve patients. Here, the HIV-1 intra-host evolutionary rate was estimated based on HIV-1 RNA sequences from plasma samples of blood donors in Japan. Blood donors were assumed to have received no treatment for and have no symptoms of HIV-1 infection because they were healthy, and declared no risky behaviors of HIV-1 infection on a self-reported questionnaire or interview followed by donation. HIV-1 RNA was obtained from 85 plasma samples from 36 blood donors who donated blood multiple times and were HIV-1-positive. The C2V3C3 region which encodes for a part of the envelope protein, and the V3 loop in the C2V3C3 region were analyzed by RT-PCR and direct sequencing, and the sequences were compared. The nucleotide substitution rate was calculated by linear regression. All HIV-1 samples analyzed were classified as subtype B. The mean nucleotide substitution rate in C2V3C3 was calculated to be 6.2 × 10 -3 -1.8 × 10 -2 /site/year (V3: 4.5 × 10 -3 -2.3 × 10 -2 /site/year). The mean non-synonymous substitution rate in C2V3C3 was calculated to be 5.2 × 10 -3 -1.7 × 10 -2 /site/year (V3: 4.5 × 10 -3 -2.1 × 10 -2 /site/year). The mean synonymous substitution rate in C2V3C3 was calculated to be 1.1 × 10 -4 -2.3 × 10 -3 /site/year (V3: 2.9 × 10 -3 /site/year). Among HIV-1 subtype B RNA-positive blood donors in Japan, the nucleotide substitution rate in C2V3C3 was estimated to be higher than that of reported cases using HIV-1 samples mainly obtained from AIDS patients. Compared to AIDS patients, immune responses against HIV-1 are probably more effective in HIV-1 RNA-positive blood donors. Consequently, immune pressure presumably promotes mutation of the virus genome.
Reconstruction of an input function from a dynamic PET water image using multiple tissue curves
NASA Astrophysics Data System (ADS)
Kudomi, Nobuyuki; Maeda, Yukito; Yamamoto, Yuka; Nishiyama, Yoshihiro
2016-08-01
Quantification of cerebral blood flow (CBF) is important for the understanding of normal and pathologic brain physiology. When CBF is assessed using PET with {{\\text{H}}2} 15O or C15O2, its calculation requires an arterial input function, which generally requires invasive arterial blood sampling. The aim of the present study was to develop a new technique to reconstruct an image derived input function (IDIF) from a dynamic {{\\text{H}}2} 15O PET image as a completely non-invasive approach. Our technique consisted of using a formula to express the input using tissue curve with rate constant parameter. For multiple tissue curves extracted from the dynamic image, the rate constants were estimated so as to minimize the sum of the differences of the reproduced inputs expressed by the extracted tissue curves. The estimated rates were used to express the inputs and the mean of the estimated inputs was used as an IDIF. The method was tested in human subjects (n = 29) and was compared to the blood sampling method. Simulation studies were performed to examine the magnitude of potential biases in CBF and to optimize the number of multiple tissue curves used for the input reconstruction. In the PET study, the estimated IDIFs were well reproduced against the measured ones. The difference between the calculated CBF values obtained using the two methods was small as around <8% and the calculated CBF values showed a tight correlation (r = 0.97). The simulation showed that errors associated with the assumed parameters were <10%, and that the optimal number of tissue curves to be used was around 500. Our results demonstrate that IDIF can be reconstructed directly from tissue curves obtained through {{\\text{H}}2} 15O PET imaging. This suggests the possibility of using a completely non-invasive technique to assess CBF in patho-physiological studies.
NASA Astrophysics Data System (ADS)
Khoury, David S.; Cromer, Deborah; Best, Shannon E.; James, Kylie R.; Sebina, Ismail; Haque, Ashraful; Davenport, Miles P.
2015-05-01
The best correlate of malaria severity in human Plasmodium falciparum (Pf) infection is the total parasite load. Pf-infected humans could control parasite loads by two mechanisms, either decreasing parasite multiplication, or increasing parasite clearance. However, few studies have directly measured these two mechanisms in vivo. Here, we have directly quantified host clearance of parasites during Plasmodium infection in mice. We transferred labelled red blood cells (RBCs) from Plasmodium infected donors into uninfected and infected recipients, and tracked the fate of donor parasites by frequent blood sampling. We then applied age-based mathematical models to characterise parasite clearance in the recipient mice. Our analyses revealed an increased clearance of parasites in infected animals, particularly parasites of a younger developmental stage. However, the major decrease in parasite multiplication in infected mice was not mediated by increased clearance alone, but was accompanied by a significant reduction in the susceptibility of RBCs to parasitisation.
Araujo, Sergio; Freitas, Larissa Oliveira; Goulart, Luiz Ricardo; Goulart, Isabela Maria Bernardes
2016-12-01
Leprosy persists as a public health problem. The chain of transmission and mechanism of infection are not completely understood. In the current study, we investigated the route of infection and of disease onset, from airway exposure, colonization, and bloodstream dissemination. Mycobacterium leprae DNA was detected through quantitative polymerase chain reaction in nasal vestibule, nasal turbinate mucosa, and peripheral blood samples, along with anti-phenolic glycolipid I serology and skin tests from the same individual, from 113 leprosy patients and 104 household contacts of patients (HHCs). Bivariate statistics and multiple correspondence analysis were employed. The rates of DNA positivity among patients were 66.4% (75 of 113) for nasal swab samples, 71.7% (81 of 113) for nasal turbinate biopsy samples, 19.5% (22 of 113) for blood samples, with seropositivity of 62.8% (71 of 113 samples) and with increasing incidences toward the multibacillary pole of the clinical spectrum. Positivity among HHCs were as follows: 49% (51 of 104) for nasal swab samples, 53.8% (56 of 104) for nasal biopsy samples, 6.7% (7 of 104) for blood samples, and 18.3% (19 of 104 samples) for anti-phenolic glycolipid I serology. During the follow-up of 5-7 years, out of 104 HHCs, 7 developed leprosy (6.7%). Risk for the disease outcome was estimated by comparing results in HHCs who develop leprosy with those not affected. Neither nasal passage nor mucosa positivity was determinant of later disease onset; however, blood presence increased the risk for disease development (relative risk/positive likelihood ratio, 5.54; 95% confidence interval, 1.30-23.62), as did seropositivity (positive likelihood ratio, 3.69 [1.67-8.16]; relative risk, 5.97 [1.45-24.5]). Our findings strongly suggest that the aerosol route of infection and transmission is predominant and that HHCs contribute to the infection risk to themselves and probably to others. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.
PARALLEL ASSAY OF OXYGEN EQUILIBRIA OF HEMOGLOBIN
Lilly, Laura E.; Blinebry, Sara K.; Viscardi, Chelsea M.; Perez, Luis; Bonaventura, Joe; McMahon, Tim J.
2013-01-01
Methods to systematically analyze in parallel the function of multiple protein or cell samples in vivo or ex vivo (i.e. functional proteomics) in a controlled gaseous environment have thus far been limited. Here we describe an apparatus and procedure that enables, for the first time, parallel assay of oxygen equilibria in multiple samples. Using this apparatus, numerous simultaneous oxygen equilibrium curves (OECs) can be obtained under truly identical conditions from blood cell samples or purified hemoglobins (Hbs). We suggest that the ability to obtain these parallel datasets under identical conditions can be of immense value, both to biomedical researchers and clinicians who wish to monitor blood health, and to physiologists studying non-human organisms and the effects of climate change on these organisms. Parallel monitoring techniques are essential in order to better understand the functions of critical cellular proteins. The procedure can be applied to human studies, wherein an OEC can be analyzed in light of an individual’s entire genome. Here, we analyzed intraerythrocytic Hb, a protein that operates at the organism’s environmental interface and then comes into close contact with virtually all of the organism’s cells. The apparatus is theoretically scalable, and establishes a functional proteomic screen that can be correlated with genomic information on the same individuals. This new method is expected to accelerate our general understanding of protein function, an increasingly challenging objective as advances in proteomic and genomic throughput outpace the ability to study proteins’ functional properties. PMID:23827235
NASA Astrophysics Data System (ADS)
Fung, Edward K.; Carson, Richard E.
2013-03-01
Full quantitative analysis of brain PET data requires knowledge of the arterial input function into the brain. Such data are normally acquired by arterial sampling with corrections for delay and dispersion to account for the distant sampling site. Several attempts have been made to extract an image-derived input function (IDIF) directly from the internal carotid arteries that supply the brain and are often visible in brain PET images. We have devised a method of delineating the internal carotids in co-registered magnetic resonance (MR) images using the level-set method and applying the segmentations to PET images using a novel centerline approach. Centerlines of the segmented carotids were modeled as cubic splines and re-registered in PET images summed over the early portion of the scan. Using information from the anatomical center of the vessel should minimize partial volume and spillover effects. Centerline time-activity curves were taken as the mean of the values for points along the centerline interpolated from neighboring voxels. A scale factor correction was derived from calculation of cerebral blood flow (CBF) using gold standard arterial blood measurements. We have applied the method to human subject data from multiple injections of [15O]water on the HRRT. The method was assessed by calculating the area under the curve (AUC) of the IDIF and the CBF, and comparing these to values computed using the gold standard arterial input curve. The average ratio of IDIF to arterial AUC (apparent recovery coefficient: aRC) across 9 subjects with multiple (n = 69) injections was 0.49 ± 0.09 at 0-30 s post tracer arrival, 0.45 ± 0.09 at 30-60 s, and 0.46 ± 0.09 at 60-90 s. Gray and white matter CBF values were 61.4 ± 11.0 and 15.6 ± 3.0 mL/min/100 g tissue using sampled blood data. Using IDIF centerlines scaled by the average aRC over each subjects’ injections, gray and white matter CBF values were 61.3 ± 13.5 and 15.5 ± 3.4 mL/min/100 g tissue. Using global average aRC values, the means were unchanged, and intersubject variability was noticeably reduced. This MR-based centerline method with local re-registration to [15O]water PET yields a consistent IDIF over multiple injections in the same subject, thus permitting the absolute quantification of CBF without arterial input function measurements.
HLA typing in patients with multiple evanescent white dot syndrome (MEWDS).
Borruat, F X; Herbort, C P; Spertini, F; Desarnaulds, A B
1998-03-01
Multiple evanescent white dot syndrome (MEWDS) is an acquired chorioretinal disorder of unknown etiology. We investigated the possibility that MEWDS might be related to a specific HLA subtyping. Blood was obtained from nine patients affected by MEWDS. HLA-B51 was found in four of these nine patients with MEWDS. There was a 3.7-fold increased frequency of HLA-B51 in patients affected by MEWDS (relative risk 5.86). MEWDS might then be related to the presence of a specific HLA subtype, HLA-B51. However, due to the small sample size, our results need to be confirmed by further testing.
Schauer, Amanda P; Sykes, Craig; Cottrell, Mackenzie L; Prince, Heather; Kashuba, Angela D M
2018-02-05
The ability to monitor adherence to antiretroviral therapy is critical for the interpretation of outcomes from clinical studies of HIV, and for optimizing patient care. The antiretrovirals tenofovir (TFV), emtricitabine (FTC), and lamivudine (3TC) are commonly included in drug regimens for HIV prevention and treatment. The active form of the drugs tenofovir diphosphate (TFVdp), emtricitabine triphosphate (FTCtp), and lamivudine triphosphate (3TCtp) are found intracellularly in erythrocytes and peripheral blood mononuclear cells (PBMCs). The ability to collect and analyze dried blood spot (DBS) samples is an attractive alternative to PBMC sampling in many resource limited settings. We developed and validated an assay to quantify all three intracellular metabolites over the range of 100-25000 fmol/sample. This assay utilizes a simple protein precipitation/liquid-liquid extraction of a single 3-mm DBS punch (from a Whatman 903 Protein Saver card) with isotopically labeled 13 C 5 -TFVdp included as the internal standard. Following extraction, samples are analyzed by anion exchange chromatography on a Thermo Biobasic AX 5μm column with detection by electrospray ionization in the positive mode on a AB Sciex API-5000 triple quadrupole mass spectrometer with a total run time of 8min. The assay was linear over the entire range (R 2 >0.996). The assay was accurate (inter-assay%bias within ±3.0%) and precise (inter-assay % CV≤9.8%). The assay was also reproducible from multiple punches within a spot as well as punches from separate blood spots. Stability was established at room temperature for 3days, and at -80°C for up to 63days. Clinical samples were analyzed from subjects on Truvada ® , Stribild ® , Descovy ® , and Triumeq ® regimens and intracellular metabolites were detected in all samples as expected, indicating the assay performs well for all current formulations of TFV, FTC, and 3TC. Copyright © 2017 Elsevier B.V. All rights reserved.
Finning, Kirstin; Bhandari, Radhika; Sellers, Fiona; Revelli, Nicoletta; Villa, Maria Antonietta; Muñiz-Díaz, Eduardo; Nogués, Núria
2016-03-01
High-throughput genotyping platforms enable simultaneous analysis of multiple polymorphisms for blood group typing. BLOODchip® ID is a genotyping platform based on Luminex® xMAP technology for simultaneous determination of 37 red blood cell (RBC) antigens (ID CORE XT) and 18 human platelet antigens (HPA) (ID HPA XT) using the BIDS XT software. In this international multicentre study, the performance of ID CORE XT and ID HPA XT, using the centres' current genotyping methods as the reference for comparison, and the usability and practicality of these systems, were evaluated under working laboratory conditions. DNA was extracted from whole blood in EDTA with Qiagen methodologies. Ninety-six previously phenotyped/genotyped samples were processed per assay: 87 testing samples plus five positive controls and four negative controls. Results were available for 519 samples: 258 with ID CORE XT and 261 with ID HPA XT. There were three "no calls" that were either caused by human error or resolved after repeating the test. Agreement between the tests and reference methods was 99.94% for ID CORE XT (9,540/9,546 antigens determined) and 100% for ID HPA XT (all 4,698 alleles determined). There were six discrepancies in antigen results in five RBC samples, four of which (in VS, N, S and Do(a)) could not be investigated due to lack of sufficient sample to perform additional tests and two of which (in S and C) were resolved in favour of ID CORE XT (100% accuracy). The total hands-on time was 28-41 minutes for a batch of 16 samples. Compared with the reference platforms, ID CORE XT and ID HPA XT were considered simpler to use and had shorter processing times. ID CORE XT and ID HPA XT genotyping platforms for RBC and platelet systems were accurate and user-friendly in working laboratory settings.
Optimizing cord blood sample cryopreservation.
Harris, David T
2012-03-01
Cord blood (CB) banking is becoming more and more commonplace throughout the medical community, both in the USA and elsewhere. It is now generally recognized that storage of CB samples in multiple aliquots is the preferred approach to banking because it allows the greatest number of uses of the sample. However, it is unclear which are the best methodologies for cryopreservation and storage of the sample aliquots. In the current study we analyzed variables that could affect these processes. CB were processed into mononuclear cells (MNC) and frozen in commercially available human serum albumin (HSA) or autologous CB plasma using cryovials of various sizes and cryobags. The bacteriophage phiX174 was used as a model virus to test for cross-contamination. We observed that cryopreservation of CB in HSA, undiluted autologous human plasma and 50% diluted plasma was equivalent in terms of cell recovery and cell viability. We also found that cryopreservation of CB samples in either cryovials or cryobags displayed equivalent thermal characteristics. Finally, we demonstrated that overwrapping the CB storage container in an impermeable plastic sheathing was sufficient to prevent cross-sample viral contamination during prolonged storage in the liquid phase of liquid nitrogen dewar storage. CB may be cryopreserved in either vials or bags without concern for temperature stability. Sample overwrapping is sufficient to prevent microbiologic contamination of the samples while in liquid-phase liquid nitrogen storage.
Li, Jianping; Sapkota, Achyut; Kikuchi, Daisuke; Sakota, Daisuke; Maruyama, Osamu; Takei, Masahiro
2018-07-30
Red blood cells (RBCs) aggregability A G of coagulating blood in extracorporeal circulation system has been investigated under the condition of pulsatile flow. Relaxation frequency f c from the multiple-frequency electrical impedance spectroscopy is utilized to obtain RBCs aggregability A G . Compared with other methods, the proposed multiple-frequency electrical impedance method is much easier to obtain non-invasive measurement with high speed and good penetrability performance in biology tissues. Experimental results show that, RBCs aggregability A G in coagulating blood falls down with the thrombus formation while that in non-coagulation blood almost keeps the same value, which has a great agreement with the activated clotting time (ACT) fibrinogen concertation (F bg ) tests. Modified Hanai formula is proposed to quantitatively analyze the influence of RBCs aggregation on multiple-frequency electrical impedance measurement. The reduction of RBCs aggregability A G is associated with blood coagulation reaction, which indicates the feasibility of the high speed, compact and cheap on-line thrombus measurement biosensors in extracorporeal circulation systems. Copyright © 2018 Elsevier B.V. All rights reserved.
Schaefer, Nadine; Kettner, Mattias; Laschke, Matthias W; Schlote, Julia; Peters, Benjamin; Bregel, Dietmar; Menger, Michael D; Maurer, Hans H; Ewald, Andreas H; Schmidt, Peter H
2015-05-01
A series of new synthetic cannabinoids (SC) has been consumed without any toxicological testing. For example, pharmacokinetic data have to be collected from forensic toxicological case work and/or animal studies. To develop a corresponding model for assessing such data, samples of controlled pig studies with two selected SC (JWH-210, RCS-4) and, as reference, ∆(9)-tetrahydrocannabinol (THC) should be analyzed as well as those of human cases. Therefore, a method for determination of JWH-210, RCS-4, THC, and their main metabolites in pig and human serum, whole blood, and urine samples is presented. Specimens were analyzed by liquid-chromatography tandem mass spectrometry and multiple-reaction monitoring with three transitions per compound. Full validation was carried out for the pig specimens and cross-validation for the human specimens concerning precision and bias. For the pig studies, the limits of detection were between 0.05 and 0.50 ng/mL in serum and whole blood and between 0.05 and 1.0 ng/mL in urine, the lower limits of quantification between 0.25 and 1.0 ng/mL in serum and 0.50 and 2.0 ng/mL in whole blood and urine, and the intra- and interday precision values lower than 15% and bias values within ±15%. The applicability was tested with samples taken from a pharmacokinetic pilot study with pigs following intravenous administration of a mixture of 200 μg/kg body mass dose each of JWH-210, RCS-4, and THC. The cross-validation data for human serum, whole blood, and urine showed that this approach should also be suitable for human specimens, e.g., of clinical or forensic cases.
[Analysis of causes and whole microbial structure in a case of rampant caries].
Hu, Xiao-Yu; Yao, Yu-Fei; Cui, Bo-Miao; Lv, Jun; Shen, Xin; Ren, Biao; Li, Ming-Yun; Guo, Qiang; Huang, Rui-Jie; Li, Yan
2016-10-20
To analyze the whole microbial structure in a case of rampant caries to provide evidence for its prevention and treatment. Clinical samples including blood, supragingival plaque, plaque in the caries cavity, saliva, and mucosal swabs were collected with the patient's consent. The blood sample was sent for routine immune test, and the others samples were stained using Gram method and cultured for identifying colonies and 16S rRNA sequencing. DNA was extracted from the samples and tested for the main cariogenic bacterium (Streptococcus mutans) with qPCR, and the whole microbial structure was analyzed using DGGE. The patient had a high levels of IgE and segmented neutrophils in his blood. Streptococci with extremely long chains were found in the saliva samples under microscope. Culture of the samples revealed the highest bacterial concentration in the saliva. The relative content of hemolytic bacterium was detected in the samples, the highest in the caries cavity; C. albicans was the highest in the dental plaque. In addition, 33 bacterial colonies were identified by VITEK system and 16S rDNA sequence phylogenetic analysis, and among them streptococci and Leptotrichia wade were enriched in the dental plaque sample, Streptococcus mutans, Fusobacterium nucleatum, and Streptococcus tigurinus in the caries cavity, and Lactobacillus in the saliva. S. mutans was significantly abundant in the mucosal swabs, saliva and plaque samples of the caries cavity as shown by qPCR. Compared to samples collected from a healthy individual and another two patients with rampant caries, the samples from this case showed a decreased bacterial diversity and increased bacterial abundance shown by PCR-DGGE profiling, and multiple Leptotrichia sp. were detected by gel sequencing. The outgrowth of such pathogenic microorganisms as S. mutans and Leptotrichia sp., and dysbiosis of oral microbial community might contribute to the pathogenesis of rampant caries in this case.
Steffen, Imke; Tyrrell, D. Lorne; Stein, Eleanor; Montalvo, Leilani; Lee, Tzong-Hae; Zhou, Yanchen; Lu, Kai; Switzer, William M.; Tang, Shaohua; Jia, Hongwei; Hockman, Darren; Santer, Deanna M.; Logan, Michael; Landi, Amir; Law, John; Houghton, Michael; Simmons, Graham
2011-01-01
The gammaretroviruses xenotropic murine leukemia virus (MLV)-related virus (XMRV) and MLV have been reported to be more prevalent in plasma and peripheral blood mononuclear cells of chronic fatigue syndrome (CFS) patients than in healthy controls. Here, we report the complex analysis of whole blood and plasma samples from 58 CFS patients and 57 controls from Canada for the presence of XMRV/MLV nucleic acids, infectious virus, and XMRV/MLV-specific antibodies. Multiple techniques were employed, including nested and qRT-PCR, cell culture, and immunoblotting. We found no evidence of XMRV or MLV in humans and conclude that CFS is not associated with these gammaretroviruses. PMID:22114717
Comparison of three optical methods to study erythrocyte aggregation.
Zhao, H; Wang, X; Stoltz, J F
1999-01-01
The aim of this work was to evaluate three optical methods designed to determine erythrocyte aggregation: Erythroaggregometer (EA; Regulest, France), Laser-assisted Optical Rotational Cell Analyzer (LORCA; Mechatronics, Netherlands) and Fully Automatic Erythrocyte Aggregometer (FAEA; Myrenne, GmbH, Germany). Blood samples were taken from fifty donors (26 males and 24 females). The aggregation of normal red blood cell (RBC) and RBCs suspended in three normo- and hyperaggregating suspending media was studied. The results revealed some significant correlations between parameters measured by these instruments, in particular, between the indexes of aggregation of EA and LORCA. Further, RBC aggregation of multiple myeloma patients was also studied and a hyper erythrocyte aggregation state was found by EA and LORCA.
Taylor, Rachel R; Hoffman, Keith L; Schniedewind, Björn; Clavijo, Claudia; Galinkin, Jeffrey L; Christians, Uwe
2013-09-01
Acetaminophen (paracetamol, N-(4-hydroxyphenyl) acetamide) is one of the most commonly prescribed drugs for the management of pain in children. Quantification of acetaminophen in pre-term and term neonates and small children requires the availability of highly sensitive assays in small volume blood samples. We developed and validated an LC-MS/MS assay for the quantification of acetaminophen in human plasma, cerebro-spinal fluid (CSF) and dried blood spots (DBS). Reconstitution in water (DBS only) and addition of a protein precipitation solution containing the deuterated internal standard were the only manual steps. Extracted samples were analyzed on a Kinetex 2.6 μm PFP column using an acetonitrile/formic acid gradient. The analytes were detected in the positive multiple reaction mode. Alternatively, DBS were automatically processed using direct desorption in a sample card and preparation (SCAP) robotic autosampler in combination with online extraction. The range of reliable response in plasma and CSF was 3.05-20,000 ng/ml (r(2)>0.99) and 27.4-20,000 ng/ml (r(2)>0.99) for DBS (manual extraction and automated direct desorption). Inter-day accuracy was always within 85-115% and inter-day precision for plasma, CSF and manually extracted DBS were less than 15%. Deming regression analysis comparing 167 matching pairs of plasma and DBS samples showed a correlation coefficient of 0.98. Bland Altman analysis indicated a 26.6% positive bias in DBS, most likely reflecting the blood: plasma distribution ratio of acetaminophen. DBS are a valid matrix for acetaminophen pharmacokinetic studies. Copyright © 2013 Elsevier B.V. All rights reserved.
Ji, S C; Pan, Y T; Lu, Q Y; Sun, Z Y; Liu, Y Z
2014-03-17
The purpose of this study was to identify critical genes associated with septic multiple trauma by comparing peripheral whole blood samples from multiple trauma patients with and without sepsis. A microarray data set was downloaded from the Gene Expression Omnibus (GEO) database. This data set included 70 samples, 36 from multiple trauma patients with sepsis and 34 from multiple trauma patients without sepsis (as a control set). The data were preprocessed, and differentially expressed genes (DEGs) were then screened for using packages of the R language. Functional analysis of DEGs was performed with DAVID. Interaction networks were then established for the most up- and down-regulated genes using HitPredict. Pathway-enrichment analysis was conducted for genes in the networks using WebGestalt. Fifty-eight DEGs were identified. The expression levels of PLAU (down-regulated) and MMP8 (up-regulated) presented the largest fold-changes, and interaction networks were established for these genes. Further analysis revealed that PLAT (plasminogen activator, tissue) and SERPINF2 (serpin peptidase inhibitor, clade F, member 2), which interact with PLAU, play important roles in the pathway of the component and coagulation cascade. We hypothesize that PLAU is a major regulator of the component and coagulation cascade, and down-regulation of PLAU results in dysfunction of the pathway, causing sepsis.
Balijepalli, Chakrapani; Bramlage, Peter; Lösch, Christian; Zemmrich, Claudia; Humphries, Karin H; Moebus, Susanne
2014-06-01
Contemporary epidemiological data on blood pressure readings, hypertension prevalence and control in unselected patient populations covering a broad age range are scarce. The aim here is to report the prevalence of high blood pressure and to identify factors associated with blood pressure control in a large German primary care sample. We used data from the German Metabolic and Cardiovascular Risk Study including 35 869 patients aged 18-99 years. High blood pressure was defined as systolic blood pressure ≥140 mm Hg and/or diastolic blood pressure ≥90 mm Hg or using antihypertensive therapy. Factors associated with blood pressure control among patients receiving antihypertensive therapy were examined using multiple logistic regressions to estimate odds ratios and 95% confidence intervals. The prevalence of high blood pressure, uncontrolled high blood pressure and untreated high blood pressure was 54.8%, 21.3% and 17.6%, respectively. Age >50 years (1.52; 1.40-1.65), male sex (1.30; 1.20-1.41), elevated waist circumference (1.55; 1.45-1.65), high cholesterol (1.24; 1.16-1.33), high triglycerides (1.11; 1.04-1.19) and concomitant diabetes (1.29; 1.20-1.40) were independently associated with uncontrolled high blood pressure. In a majority of patients we observed hypertension despite treatment for high blood pressures. Studies examining the reasons for treatment failure are highly warranted.
Zhu, Jianjie; Chen, Lanxin; Mao, Yong; Zhou, Huan
2013-01-01
Allele-specific amplification on the basis of polymerase chain reaction (PCR) has been widely used for single-nucleotide polymorphism (SNP) genotyping. However, the extraction of PCR-compatible genomic DNA from whole blood is usually required. This process is complicated and tedious, and is prone to cause cross-contamination between samples. To facilitate direct PCR amplification from whole blood without the extraction of genomic DNA, we optimized the pH value of PCR solution and the concentrations of magnesium ions and facilitator glycerol. Then, we developed multiplex allele-specific amplifications from whole blood and applied them to a case–control study. In this study, we successfully established triplex, five-plex, and eight-plex allele-specific amplifications from whole blood for determining the distribution of genotypes and alleles of 14 polymorphisms in 97 gastric cancer patients and 141 healthy controls. Statistical analysis results showed significant association of SNPs rs9344, rs1799931, and rs1800629 with the risk of gastric cancer. This method is accurate, time-saving, cost-effective, and easy-to-do, especially suitable for clinical prediction of disease susceptibility. PMID:23072573
Yan, Jin; Gao, Zhenyan; Wang, Ju; Ma, Wenjuan; Ying, Xiaolan; Zhou, Cancan; Yan, Chonghuai
2018-05-01
To explore the potential environmental and dietary factors during pregnancy affecting low-level prenatal lead exposure, we conducted a longitudinal study in Wujiang City, China. A total of 1976 mother-infant pairs were included from 2009 to 2010. An interviewed questionnaire was conducted and cord blood samples were collected. The geometric means of cord blood lead level was 30.3 μg/L (95% CI, 29.8-30.8) with 99.24% below 100 μg/L. Maternal age, passive smoking, and living in the countryside were significantly associated with cord blood lead concentrations. Multiple logistic models showed that some family environmental factors including using firewood and electricity as kitchen fuel were positively correlated with increased cord blood lead levels. Among dietary sources recorded in this study, meat consumption (> 3 times/week), fish consumption (1-3 times/week), vegetables consumption (> 1 times/day), and fruit intake (> 1 times/day) had inverse relationship with cord blood lead levels. In general, our findings may have important implications for family environmental and dietary direction during pregnancy to decrease prenatal lead exposure.
Curcic, Marijana; Buha, Aleksandra; Stankovic, Sanja; Milovanovic, Vesna; Bulat, Zorica; Đukić-Ćosić, Danijela; Antonijević, Evica; Vučinić, Slavica; Matović, Vesna; Antonijevic, Biljana
2017-02-01
The objective of this study was to assess toxicity of Cd and BDE-209 mixture on haematological parameters in subacutely exposed rats and to determine the presence and type of interactions between these two chemicals using multiple factorial regression analysis. Furthermore, for the assessment of interaction type, an isobologram based methodology was applied and compared with multiple factorial regression analysis. Chemicals were given by oral gavage to the male Wistar rats weighing 200-240g for 28days. Animals were divided in 16 groups (8/group): control vehiculum group, three groups of rats were treated with 2.5, 7.5 or 15mg Cd/kg/day. These doses were chosen on the bases of literature data and reflect relatively high Cd environmental exposure, three groups of rats were treated with 1000, 2000 or 4000mg BDE-209/kg/bw/day, doses proved to induce toxic effects in rats. Furthermore, nine groups of animals were treated with different mixtures of Cd and BDE-209 containing doses of Cd and BDE-209 stated above. Blood samples were taken at the end of experiment and red blood cells, white blood cells and platelets counts were determined. For interaction assessment multiple factorial regression analysis and fitted isobologram approach were used. In this study, we focused on multiple factorial regression analysis as a method for interaction assessment. We also investigated the interactions between Cd and BDE-209 by the derived model for the description of the obtained fitted isobologram curves. Current study indicated that co-exposure to Cd and BDE-209 can result in significant decrease in RBC count, increase in WBC count and decrease in PLT count, when compared with controls. Multiple factorial regression analysis used for the assessment of interactions type between Cd and BDE-209 indicated synergism for the effect on RBC count and no interactions i.e. additivity for the effects on WBC and PLT counts. On the other hand, isobologram based approach showed slight antagonism for the effects on RBC and WBC while no interactions were proved for the joint effect on PLT count. These results confirm that the assessment of interactions between chemicals in the mixture greatly depends on the concept or method used for this evaluation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Garner, Rochelle E; Levallois, Patrick
2017-05-01
Cadmium has been inconsistently related to blood pressure and hypertension. The present study seeks to clarify the relationship between cadmium levels found in blood and urine, blood pressure and hypertension in a large sample of adults. The study sample included participants ages 20 through 79 from multiple cycles of the Canadian Health Measures Survey (2007 through 2013) with measured blood cadmium (n=10,099) and urinary cadmium (n=6988). Linear regression models examined the association between natural logarithm transformed cadmium levels and blood pressure (separate models for systolic and diastolic blood pressure) after controlling for known covariates. Logistic regression models were used to examine the association between cadmium and hypertension. Models were run separately by sex, smoking status, and body mass index category. Men had higher mean systolic (114.8 vs. 110.8mmHg, p<0.01) and diastolic (74.0 vs. 69.6mmHg, p<0.01) blood pressure compared to women. Although, geometric mean blood (0.46 vs. 0.38µg/L, p<0.01) and creatinine-adjusted standardized urinary cadmium levels (0.48 vs. 0.38µg/L, p<0.01) were higher among those with hypertension, these differences were no longer significant after adjustment for age, sex and smoking status. In overall regression models, increases in blood cadmium were associated with increased systolic (0.70mmHg, 95% confidence interval [CI]=0.25-1.16, p<0.01) and diastolic blood pressure (0.74mmHg, 95% CI=0.30-1.19, p<0.01). The associations between urinary cadmium, blood pressure and hypertension were not significant in overall models. Model stratification revealed significant and negative associations between urinary cadmium and hypertension among current smokers (OR=0.61, 95% CI=0.44-0.85, p<0.01), particularly female current smokers (OR=0.52, 95% CI=0.32-0.85, p=0.01). This study provides evidence of a significant association between cadmium levels, blood pressure and hypertension. However, the significance and direction of this association differs by sex, smoking status, and body mass index category. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.
Beer, Lynn A; Wang, Huan; Tang, Hsin-Yao; Cao, Zhijun; Chang-Wong, Tony; Tanyi, Janos L; Zhang, Rugang; Liu, Qin; Speicher, David W
2013-01-01
The most cancer-specific biomarkers in blood are likely to be proteins shed directly by the tumor rather than less specific inflammatory or other host responses. The use of xenograft mouse models together with in-depth proteome analysis for identification of human proteins in the mouse blood is an under-utilized strategy that can clearly identify proteins shed by the tumor. In the current study, 268 human proteins shed into mouse blood from human OVCAR-3 serous tumors were identified based upon human vs. mouse species differences using a four-dimensional plasma proteome fractionation strategy. A multi-step prioritization and verification strategy was subsequently developed to efficiently select some of the most promising biomarkers from this large number of candidates. A key step was parallel analysis of human proteins detected in the tumor supernatant, because substantially greater sequence coverage for many of the human proteins initially detected in the xenograft mouse plasma confirmed assignments as tumor-derived human proteins. Verification of candidate biomarkers in patient sera was facilitated by in-depth, label-free quantitative comparisons of serum pools from patients with ovarian cancer and benign ovarian tumors. The only proteins that advanced to multiple reaction monitoring (MRM) assay development were those that exhibited increases in ovarian cancer patients compared with benign tumor controls. MRM assays were facilely developed for all 11 novel biomarker candidates selected by this process and analysis of larger pools of patient sera suggested that all 11 proteins are promising candidate biomarkers that should be further evaluated on individual patient blood samples.
Self-powered integrated microfluidic point-of-care low-cost enabling (SIMPLE) chip
Yeh, Erh-Chia; Fu, Chi-Cheng; Hu, Lucy; Thakur, Rohan; Feng, Jeffrey; Lee, Luke P.
2017-01-01
Portable, low-cost, and quantitative nucleic acid detection is desirable for point-of-care diagnostics; however, current polymerase chain reaction testing often requires time-consuming multiple steps and costly equipment. We report an integrated microfluidic diagnostic device capable of on-site quantitative nucleic acid detection directly from the blood without separate sample preparation steps. First, we prepatterned the amplification initiator [magnesium acetate (MgOAc)] on the chip to enable digital nucleic acid amplification. Second, a simplified sample preparation step is demonstrated, where the plasma is separated autonomously into 224 microwells (100 nl per well) without any hemolysis. Furthermore, self-powered microfluidic pumping without any external pumps, controllers, or power sources is accomplished by an integrated vacuum battery on the chip. This simple chip allows rapid quantitative digital nucleic acid detection directly from human blood samples (10 to 105 copies of methicillin-resistant Staphylococcus aureus DNA per microliter, ~30 min, via isothermal recombinase polymerase amplification). These autonomous, portable, lab-on-chip technologies provide promising foundations for future low-cost molecular diagnostic assays. PMID:28345028
NASA Astrophysics Data System (ADS)
Shin, Seungwoo; Kim, Kyoohyun; Kim, Taeho; Yoon, Jonghee; Hong, Kihyun; Park, Jinah; Park, YongKeun
2016-03-01
Optical diffraction tomography (ODT) is an interferometric microscopy technique capable of measuring 3-D refractive index (RI) distribution of transparent samples. Multiple 2-D holograms of a sample illuminated with various angles are measured, from which 3-D RI map of the sample is reconstructed via the diffraction theory. ODT has been proved as a powerful tool for the study of biological cells, due to its non-invasiveness, label-free and quantitative imaging capability. Recently, our group has demonstrated that a digital micromirror device (DMD) can be exploited for fast and precise control of illumination beams for ODT. In this work, we systematically study the precision and stability of the ODT system equipped with a DMD and present measurements of 3-D and 4-D RI maps of various types of live cells including human red blood cells, white blood cells, hepatocytes, and HeLa cells. Furthermore, we also demonstrate the effective visualization of 3-D RI maps of live cells utilizing the measured information about the values and gradient of RI tomograms.
Hanke, A A; Dellweg, C; Kienbaum, P; Weber, C F; Görlinger, K; Rahe-Meyer, N
2010-07-01
Hypothermia and acidosis lead to an impairment of coagulation. It has been demonstrated that desmopressin improves platelet function under hypothermia. We tested platelet function ex vivo during hypothermia and acidosis. Blood samples were taken from 12 healthy subjects and assigned as follows: normal pH, pH 7.2, and pH 7.0, each with and without incubation with desmopressin. Platelet aggregation was assessed by multiple electrode aggregometry. Baseline was normal pH and 36 degrees C. The other samples were incubated for 30 min and measured at 32 degrees C. Acidosis significantly impaired aggregation. Desmopressin significantly increased aggregability during hypothermia and acidosis regardless of pH, but did not return it to normal values at low pH. During acidosis and hypothermia, acidosis should be corrected first; desmopressin can then be administered to improve platelet function as a bridge until normothermia can be achieved.
Thromboelastography in wild Florida manatees (Trichechus manatus latirostris).
Barratclough, Ashley; Floyd, Ruth Francis; Reep, Roger L; Ball, Ray L; Conner, Bobbi J
2018-03-09
Thromboelastography (TEG) provides a comprehensive evaluation of blood clot formation. This test can be used to identify abnormalities in coagulation by assessing multiple aspects of the clotting cascade, including the speed of clot initiation and formation, clot strength, and ultimately fibrinolysis. Thromboembolic disease has been hypothesized to play a role in the pathophysiology of cold stress syndrome (CSS), an important cause of mortality in the threatened Florida manatee (Trichechus manatus latirostris). The objective of this study was to establish thromboelastography RIs using the TEG 5000 with citrated whole blood samples and kaolin activation in wild, healthy manatees. In December 2014 and January 2015, 29 wild manatees (17 male and 12 female) were blood sampled as part of the annual wild manatee health assessments organized by United States Geological Survey (USGS). TEG was performed using citrated kaolin-activated samples. The samples were obtained from manatees caught in Crystal River, Citrus County, and used to identify the mean ± SD of normal TEG parameters: R = reaction time 2.1 minutes (0.8), K = clot formation time 0.8 min (0), α angle = 83.1° (2), MA = maximum amplitude 75 mm (7.6), and LY30 = clot lysis 0.41% (0.68). No significant differences were found between manatee size, sex, or time between sampling and running the test. Manatee TEG parameters demonstrate a relatively hypercoagulable condition when compared to other mammals. This information will facilitate detection of changes in hemostasis during injury and disease and provide a valuable reference range. © 2018 American Society for Veterinary Clinical Pathology.
Ghosh, Sudipta; Dosaev, Tasbulat; Prakash, Jai; Livshits, Gregory
2017-04-01
The major aim of this study was to conduct comparative quantitative-genetic analysis of the body composition (BCP) and somatotype (STP) variation, as well as their correlations with blood pressure (BP) in two ethnically, culturally and geographically different populations: Santhal, indigenous ethnic group from India and Chuvash, indigenous population from Russia. Correspondently two pedigree-based samples were collected from 1,262 Santhal and1,558 Chuvash individuals, respectively. At the first stage of the study, descriptive statistics and a series of univariate regression analyses were calculated. Finally, multiple and multivariate regression (MMR) analyses, with BP measurements as dependent variables and age, sex, BCP and STP as independent variables were carried out in each sample separately. The significant and independent covariates of BP were identified and used for re-examination in pedigree-based variance decomposition analysis. Despite clear and significant differences between the populations in BCP/STP, both Santhal and Chuvash were found to be predominantly mesomorphic irrespective of their sex. According to MMR analyses variation of BP significantly depended on age and mesomorphic component in both samples, and in addition on sex, ectomorphy and fat mass index in Santhal and on fat free mass index in Chuvash samples, respectively. Additive genetic component contributes to a substantial proportion of blood pressure and body composition variance. Variance component analysis in addition to above mentioned results suggests that additive genetic factors influence BP and BCP/STP associations significantly. © 2017 Wiley Periodicals, Inc.
Bruce, Margaret C; Bruce, Eugene N
2006-04-01
To better understand factors that influence carbon monoxide (CO) washout rates, we utilized a multicompartment mathematical model to predict rates of CO uptake, distribution in vascular and extravascular (muscle vs. other soft tissue) compartments, and washout over a range of exposure and washout conditions with varied subject-specific parameters. We fitted this model to experimental data from 15 human subjects, for whom subject-specific parameters were known, multiple washout carboxyhemoglobin (COHb) levels were available, and CO exposure conditions were identical, to investigate the contributions of exposure conditions and individual variability to CO washout from blood. We found that CO washout from venous blood was biphasic and that postexposure times at which COHb samples were obtained significantly influenced the calculated CO half times (P < 0.0001). The first, more rapid, phase of CO washout from the blood reflected the loss of CO to the expired air and to a slow uptake by the muscle compartment, whereas the second, slower washout phase was attributable to CO flow from the muscle compartment back to the blood and removal from blood via the expired air. When the model was used to predict the effects of varying exposure conditions for these subjects, the CO exposure duration, concentration, peak COHb levels, and subject-specific parameters each influenced washout half times. Blood volume divided by ventilation correlated better with half-time predictions than did cardiac output, muscle mass, or ventilation, but it explained only approximately 50% of half-time variability. Thus exposure conditions, COHb sampling times, and individual parameters should be considered when estimating CO washout rates for poisoning victims.
Ultra-fast, label-free isolation of circulating tumor cells from blood using spiral microfluidics.
Warkiani, Majid Ebrahimi; Khoo, Bee Luan; Wu, Lidan; Tay, Andy Kah Ping; Bhagat, Ali Asgar S; Han, Jongyoon; Lim, Chwee Teck
2016-01-01
Circulating tumor cells (CTCs) are rare cancer cells that are shed from primary or metastatic tumors into the peripheral blood circulation. Phenotypic and genetic characterization of these rare cells can provide important information to guide cancer staging and treatment, and thus further research into their characteristics and properties is an area of considerable interest. In this protocol, we describe detailed procedures for the production and use of a label-free spiral microfluidic device to allow size-based isolation of viable CTCs using hydrodynamic forces that are present in curvilinear microchannels. This spiral system enables us to achieve ≥ 85% recovery of spiked cells across multiple cancer cell lines and 99.99% depletion of white blood cells in whole blood. The described spiral microfluidic devices can be produced at an extremely low cost using standard microfabrication and soft lithography techniques (2-3 d), and they can be operated using two syringe pumps for lysed blood samples (7.5 ml in 12.5 min for a three-layered multiplexed chip). The fast processing time and the ability to collect CTCs from a large patient blood volume allows this technique to be used experimentally in a broad range of potential genomic and transcriptomic applications.
Ning, Jing; Rahbar, Mohammad H; Choi, Sangbum; Piao, Jin; Hong, Chuan; Del Junco, Deborah J; Rahbar, Elaheh; Fox, Erin E; Holcomb, John B; Wang, Mei-Cheng
2017-08-01
In comparative effectiveness studies of multicomponent, sequential interventions like blood product transfusion (plasma, platelets, red blood cells) for trauma and critical care patients, the timing and dynamics of treatment relative to the fragility of a patient's condition is often overlooked and underappreciated. While many hospitals have established massive transfusion protocols to ensure that physiologically optimal combinations of blood products are rapidly available, the period of time required to achieve a specified massive transfusion standard (e.g. a 1:1 or 1:2 ratio of plasma or platelets:red blood cells) has been ignored. To account for the time-varying characteristics of transfusions, we use semiparametric rate models for multivariate recurrent events to estimate blood product ratios. We use latent variables to account for multiple sources of informative censoring (early surgical or endovascular hemorrhage control procedures or death). The major advantage is that the distributions of latent variables and the dependence structure between the multivariate recurrent events and informative censoring need not be specified. Thus, our approach is robust to complex model assumptions. We establish asymptotic properties and evaluate finite sample performance through simulations, and apply the method to data from the PRospective Observational Multicenter Major Trauma Transfusion study.
The therapeutic use of cannabinoids: Forensic aspects.
Indorato, Francesca; Liberto, Aldo; Ledda, Caterina; Romano, Guido; Barbera, Nunziata
2016-08-01
Since 2013 in the Italian market has been introduced the Nabiximols, a drug containing two of the main active cannabinoids: Δ(9)-tetrahydrocannabinol (Δ(9)-THC) and cannabidiol (CBD). This drug has been approved in Italy in the treatment of Multiple Sclerosis (MS). It is an oral spray formulation and each puff of 100μl contains 2.7mg of Δ(9)-THC and 2.5mg of CBD. In the present study we analyzed urine and blood samples collected from a group of 20 patients treated with Nabiximols in order to evaluate: blood Δ(9)-THC concentrations in relation to the dose administered and the duration of treatment and the potentiality of this medication to be used for drug habit. The study was conducted on a sample group of patients affected by MS, of both sexes, age: 49-61 years, treated with Nabiximols for short (28 days) or long-term. The results of our study allow affirming that it is unlikely to use this medication for drug habit or to sale it in the black market because of the low blood concentrations available and of its high costs. These statements were confirmed by: (a) the low Δ(9)-THC concentrations in the pharmaceutical formulation; (b) the low blood concentrations produced by Nabiximols administration, more than 10 times smaller than the blood concentrations known to produce psychotropic effects; (c) the presence of CBD (Δ(9)-THC natural antagonist); (d) the route of administration (inhaled, not smoked). Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Ritter, M J; Ellis, M; Anderson, D B; Curtis, S E; Keffaber, K K; Killefer, J; McKeith, F K; Murphy, C M; Peterson, B A
2009-01-01
Sixty-four market-weight (130.0 +/- 0.65 kg) barrows (n = 16) and gilts (n = 48) were used in a split-plot design with a 2 x 2 x 2 factorial arrangement of treatments: 1) handling intensity (gentle vs. aggressive), 2) transport floor space (0.39 vs. 0.49 m(2)/pig), and 3) distance moved during handling (25 vs. 125 m) to determine the effects of multiple concurrent stressors on metabolic responses. For the handling intensity treatment, pigs were moved individually approximately 50 m through a handling course with either 0 (gentle) or 8 (aggressive) shocks from an electric goad. Pigs were loaded onto a trailer and transported for approximately 1 h at floor spaces of either 0.39 or 0.49 m(2)/pig. After transport, pigs were unloaded, and the distance moved treatment was applied; pigs were moved 25 or 125 m through a handling course using livestock paddles. Rectal temperature was measured, and blood samples (to measure blood acid-base status) were collected 2 h before the handling intensity treatment was applied and immediately after the distance moved treatment was applied. A LM sample to measure glycolytic potential was collected after the distance moved treatments on a subset of 32 pigs. There were handling intensity x distance moved interactions (P < 0.05) for several blood acid-base measurements. In general, there was no effect of distance moved on these traits when pigs were previously handled gently. However, when pigs were previously handled aggressively, pigs moved 125 compared with 25 m had greater (P < 0.05) blood lactate and less (P < 0.05) blood pH, bicarbonate, and base-excess. Pigs transported at 0.39 compared with 0.49 m(2)/pig had a greater (P < 0.01) increase in creatine kinase values; however, transport floor space did not affect any other measurements. Data were analyzed by the number of stressors (the aggressive handling, restricted transport floor space, and 125-m distance moved treatments) experienced by each pig (0, 1, 2, or 3). As the number of stressors experienced by the pig increased, rectal temperature, blood lactate, and LM lactate increased linearly (P
Chagas disease vector blood meal sources identified by protein mass spectrometry
Keller, Judith I.; Ballif, Bryan A.; St. Clair, Riley M.; Vincent, James J.; Monroy, M. Carlota
2017-01-01
Chagas disease is a complex vector borne parasitic disease involving blood feeding Triatominae (Hemiptera: Reduviidae) insects, also known as kissing bugs, and the vertebrates they feed on. This disease has tremendous impacts on millions of people and is a global health problem. The etiological agent of Chagas disease, Trypanosoma cruzi (Kinetoplastea: Trypanosomatida: Trypanosomatidae), is deposited on the mammalian host in the insect’s feces during a blood meal, and enters the host’s blood stream through mucous membranes or a break in the skin. Identifying the blood meal sources of triatomine vectors is critical in understanding Chagas disease transmission dynamics, can lead to identification of other vertebrates important in the transmission cycle, and aids management decisions. The latter is particularly important as there is little in the way of effective therapeutics for Chagas disease. Several techniques, mostly DNA-based, are available for blood meal identification. However, further methods are needed, particularly when sample conditions lead to low-quality DNA or to assess the risk of human cross-contamination. We demonstrate a proteomics-based approach, using liquid chromatography tandem mass spectrometry (LC-MS/MS) to identify host-specific hemoglobin peptides for blood meal identification in mouse blood control samples and apply LC-MS/MS for the first time to Triatoma dimidiata insect vectors, tracing blood sources to species. In contrast to most proteins, hemoglobin, stabilized by iron, is incredibly stable even being preserved through geologic time. We compared blood stored with and without an anticoagulant and examined field-collected insect specimens stored in suboptimal conditions such as at room temperature for long periods of time. To our knowledge, this is the first study using LC-MS/MS on field-collected arthropod disease vectors to identify blood meal composition, and where blood meal identification was confirmed with more traditional DNA-based methods. We also demonstrate the potential of synthetic peptide standards to estimate relative amounts of hemoglobin acquired when insects feed on multiple blood sources. These LC-MS/MS methods can contribute to developing Ecohealth control strategies for Chagas disease transmission and can be applied to other arthropod disease vectors. PMID:29232402
Porta, Miquel; Bergdahl, Ingvar A.; Palli, Domenico; Johansson, Ann-Sofie; Botsivali, Maria; Vineis, Paolo; Vermeulen, Roel; Kyrtopoulos, Soterios A.; Chadeau-Hyam, Marc
2013-01-01
Background Cadmium (Cd) and lead (Pb) are hypothesised to be risk factors for non-Hodgkin’s lymphoma (NHL), a group of haematological malignancies with a suspected environmental aetiology. Within the EnviroGenoMarkers study we utilised pre-diagnostic erythrocyte concentrations of Cd and Pb to determine whether exposure was associated with risk of B-cell NHL and multiple myeloma. Methods 194 incident cases of B-cell NHL and 76 cases of multiple myeloma diagnosed between 1990 and 2006 were identified from two existing cohorts; EPIC-Italy and the Northern Sweden Health and Disease Study. Cases were matched to healthy controls by centre, age, gender and date of blood collection. Cd and Pb were measured in blood samples provided at recruitment using inductively coupled plasma-mass spectrometry. Logistic regression was applied to assess the association with risk. Analyses were stratified by cohort and gender and by subtype where possible. Results There was little evidence of an increased risk of B-cell NHL or multiple myeloma with exposure to Cd (B-cell NHL: OR 1.09 95%CI 0.61, 1.93, MM: OR 1.16 95% CI: 0.40, 3.40 ) or Pb (B-cell NHL: 0.93 95% CI 0.43, 2.02, multiple myeloma: OR 1.63 95%CI 0.45, 5.94) in the total population when comparing the highest to the lowest quartile of exposure. However, gender and cohort specific differences in results were observed. In females the risk of B-cell NHL was more than doubled in those with a body burden of Cd >1µg/L (OR 2.20 95%CI; 1.04, 4.65). Conclusions This nested case-control study does not support a consistent positive association between Cd or Pb and NHL, but there is some indication of a gender specific effect suggesting further research is warranted. PMID:24312375
Li, Xiaojiao; Liu, Chang; Wu, Min; Zhang, Hong; Sun, Yanfu; Cheng, Longmei; Chen, Hong; Liu, Chengjiao; Yang, Lizhi; Zhang, Qi; Cao, Yuchen; Gu, Jingkai; Ding, Yanhua
2016-08-01
Trandolapril is the pro-drug of trandolaprilat, a non-sulfhydryl angiotensin-converting enzyme inhibitor. This study was designed to assess the pharmacokinetics (PK), pharmacodynamics (PD), and tolerability of single and multiple doses of trandolapril in healthy Chinese subjects. Healthy subjects (six men and six women) were randomized into a single-dose, 3 × 3 crossover study (1-2-4 mg, 2-4-1 mg, and 4-1-2 mg), and a multiple-dose study (2 mg/day, 6 days). Serial blood and urine samples were collected after drug administration and analyzed using a validated LC-MS/MS method, and the trandolapril and trandolaprilat PK parameters were obtained. PD was evaluated by the changes in blood pressure and heart rates after dosing. Tolerability was assessed by monitoring adverse events, vital signs, ECGs, and changes in laboratory tests. In the single-dose study, trandolapril was absorbed rapidly, and peak plasma levels (C max, 1.57, 3.77, and 7.99 ng/mL) and AUCs (1.89, 3.46, and 6.47 ng/mL) were dose-dependent. The AUC0-∞ of trandolaprilat was dose-dependent, but in a non-linear fashion. The cumulative urine excretion of trandolapril and trandolaprilat was 5.51, 6.20, and 7.41 % for three doses, respectively. In the multiple-dose study, steady-state pharmacokinetics was observed; there was no trandolapril accumulation, but there was mild trandolaprilat accumulation (R = 1.67). Trandolapril was well tolerated. The most pronounced reductions in blood pressure were observed at 8 h after administration, which was later than T max. No orthostatic hypotension occurred. The pharmacokinetics and pharmacodynamics following single and multiple oral doses trandolapril in healthy Chinese subjects are similar to those observed in non-Chinese healthy subjects.
Silent killers: Transfusion Transmissible Infections-TTI, among asymptomatic population of Pakistan.
Saeed, Muhammad; Hussain, Shahida; Rasheed, Farhan; Ahmad, Maqsood; Arif, Mizna; Hamid Rahmani, Muhammad Tariq
2017-03-01
To analyse transfusion transmissible infections in asymptomatic population. This study was conducted at the Allama Iqbal Medical College and Jinnah Hospital, Lahore, Pakistan, from December 2014 to November 2015, and comprised healthy asymptomatic blood donors.Every sample was screened for the presence of antibodies/antigens of hepatitis C virus, human immunodeficiency virus, treponemapallidum, hepatitis B virus and malaria parasite through rapid immunochromatographic technique. Of the 18,274 blood donors, 17,276(94.53%) were found healthy and 998(5.46%) were infected. Besides, 71(0.38%) had multiple infections. The overall frequency of anti-hepatitis C virus, treponemapallidum (syphilis), hepatitis B surface antigen, malaria parasite and anti-human immunodeficiency virus was 480(2.62%), 284(1.55%), 210(1.10%), 20(0.10%) and 4(0.02%), respectively. Blood transfusion was found to be a significant but preventable mode of spread of transfusion transmissible infections.
Triple-Label β Liquid Scintillation Counting
Bukowski, Thomas R.; Moffett, Tyler C.; Revkin, James H.; Ploger, James D.; Bassingthwaighte, James B.
2010-01-01
The detection of radioactive compounds by liquid scintillation has revolutionized modern biology, yet few investigators make full use of the power of this technique. Even though multiple isotope counting is considerably more difficult than single isotope counting, many experimental designs would benefit from using more than one isotope. The development of accurate isotope counting techniques enabling the simultaneous use of three β-emitting tracers has facilitated studies in our laboratory using the multiple tracer indicator dilution technique for assessing rates of transmembrane transport and cellular metabolism. The details of sample preparation, and of stabilizing the liquid scintillation spectra of the tracers, are critical to obtaining good accuracy. Reproducibility is enhanced by obtaining detailed efficiency/quench curves for each particular set of tracers and solvent media. The numerical methods for multiple-isotope quantitation depend on avoiding error propagation (inherent to successive subtraction techniques) by using matrix inversion. Experimental data obtained from triple-label β counting illustrate reproducibility and good accuracy even when the relative amounts of different tracers in samples of protein/electrolyte solutions, plasma, and blood are changed. PMID:1514684
Zhang, Y W; Gao, H; Huang, K; Xu, Y Y; Sheng, J; Tao, F B
2017-03-10
Objective: To examine the association between the phthalate exposure in the first trimester and fasting blood glucose level or gestational diabetes mellitus (GDM) in the third trimester in pregnant women. Methods: A total of 3 474 pregnant women, receiving their prenatal examination in Ma' anshan Maternal and Child Health-Care Hospital of Anhui province, were selected from May 2013 to September 2014. Questionnaires were used to collect the information about their socio-demographic characteristics, clinical characteristics and GDM diagnostic results in the first, second and third trimesters. Urine samples and fasting venous blood samples were collected. Concentrations of 7 kinds of phthalate metabolites in urine samples were detected by solid phase extraction-high performance liquid chromatography-tandem mass spectrometry (SPE-HPLC-MS/MS), and multiple linear regression model was used for statistical analyses. Logistic regression analysis on the risk of the first trimester phthalate exposure for GDM in the third trimester was conducted. Results: The prevalence of GDM in this study was 12.8%, monomethyl phthalate (MMP), monoethyl phthalate (MEP), mono-n-butyl phthalate (MBP), monobenzyl phthalate (MBzP) and mono-(2-ethyl-5-oxohexyl) phthalate (MEHHP) exposure levels were positively correlated with the fasting blood glucose level in the third trimester ( P <0.05), but mono-(2-ethylhexyl) phthalate (MEHP) and mono-(2-ethyl-5-hydroxylhexyl) phthalate (MEOHP) exposure levels were negatively correlated with the fasting blood glucose level in the third trimester ( P <0.05). Stratified analysis showed a positive correlation between MEHHP exposure and the third trimester fasting blood glucose level in both normal group and GDM group. However, MMP, MEP, MBP, MBzP, MEHP and MEOHP exposure levels had influences on the third trimester fasting blood glucose level in normal group but not in GDM group. MMP and MBP exposure might increase the risk of GDM, but MEOHP exposure might reduce the risk of GDM. Conclusion: The phthalate exposure in the first trimester might be associated with the fasting blood glucose level in the third trimester, MMP, MEP, MBP, MBzP and MEHHP concentrations were positively associated with the third trimester blood glucose level, MEHP and MEOHP concentrations were negatively associated with the third trimester blood glucose level. Moreover, the effects of different kinds of phthalates might be different.
Detection of lipopolysaccharides in serum using a waveguide-based optical biosensor
NASA Astrophysics Data System (ADS)
Noormohamed, Aneesa; Stromberg, Loreen R.; Anderson, Aaron S.; Karim, Zachary; Dighe, Priya; Kempaiah, Prakasha; Ong'echa, John M.; Perkins, Douglas J.; Doggett, Norman; McMahon, Benjamin; Mukundan, Harshini
2017-02-01
Direct ultra-sensitive detection of pathogen biomarkers in blood could provide a universal strategy for diagnosis of bacterial infections, which remain a leading cause of morbidity and mortality in many areas of the world. Many factors complicate diagnosis, including the presence of multiple co-infections in a given patient, and lack of infrastructure in rural settings. In some pediatric patients, such as those in areas with poor resources, an additional challenge exists with low sample volumes due to age and other health factors such as anemia and dehydration. Our team is working on developing novel diagnostic assays, with a waveguide-based biosensor platform, to rapidly and specifically identify pathogen biomarkers from small samples of serum or plasma, allowing for the timely and sensitive diagnosis of infection at the point of care. In addition to the platform, we have developed novel membrane insertion and lipoprotein capture assay methods, to capture lipidated pathogen biomarkers in aqueous blood, by virtue of their interactions with host lipoprotein carriers. Herein, we demonstrate our efforts to adapt the lipoprotein capture assay for the detection of small concentrations of pathogen-secreted lipopolysaccharides in aqueous blood, with the ultimate aim of diagnosing Gram-negative infections effectively.
Blood lead levels following consumption of game meat in Italy.
Fustinoni, Silvia; Sucato, Sabrina; Consonni, Dario; Mannucci, Pier Mannuccio; Moretto, Angelo
2017-05-01
The aim of this study was to measure lead (Pb) levels in blood (Pb-blood) in consumers of game meat, taking into account other possible sources of lead exposure. A spot blood sample was obtained from 95 subjects, and a questionnaire was used to collect general information and data on game meat consumption, hunting, wine drinking and other possible sources of lead exposure. Pb-blood was measured by inductively coupled plasma-mass spectrometry. Pb-blood was not influenced by age, sex, residence in an urban or rural area, consumption of game meat, tobacco smoking or hobbies associated with potential exposure to lead, and median Pb-blood was 1.7 (5th-95th percentile 1.0-5.3)µg/dL and 3.4 (0.9-6.1)µg/dL for game meat non-eaters and eater, respectively. A multiple linear regression analysis (containing the covariates sex, age, hunting, wine drinking, game meat consumption, tobacco smoking, shooting range, and occupational exposure) found an association with hunting (Pb-blood almost double in hunters) and wine drinking (40% higher in drinkers) but not with consumption of game meat or other parameters. Whether the higher Pb-blood level was due to inhalation of lead fumes while shooting with lead ammunition, to handling lead ammunition or both could not be ascertained. Copyright © 2017 Elsevier Inc. All rights reserved.
Mochalski, Paweł; King, Julian; Kupferthaler, Alexander; Unterkofler, Karl; Hinterhuber, Hartmann; Amann, Anton
2011-12-01
The aim of this study was to determine the solubility (liquid-to-air ratios) of isoprene in water, human blood and plasma. To this end, an experimental setup combining multiple headspace extraction, solid phase microextraction and gas chromatography-mass spectrometry was applied. The water:air partition coefficients of isoprene were determined for the temperature range 4.5-37 °C and amounted to 1.171-0.277 (g mL(l)(-1)) (g mL(a)(-1))(-1). On the basis of these data, the enthalpy of volatilization was calculated as 29.46 ± 2.83 kJ mol(-1). The blood:air partition coefficients at 37 °C were determined for ten normal healthy volunteers spread around a median value of 0.95 ± 0.09 (g mL(l)(-1)) (g mL(a)(-1))(-1) and were approximately 16% lower than the plasma:air partition coefficients (1.11 ± 0.2). The applied methodology can be particularly attractive for solubility studies targeting species at very low concentrations in the solution, i.e. when headspace sample enrichment is necessary to provide sufficient measurement sensitivity and reliability. This can be especially helpful if environmental or physiological solute levels have to be considered.
Trend, Stephanie; Jones, Anderson P.; Geldenhuys, Sian; Byrne, Scott N.; Fabis-Pedrini, Marzena J.; Nolan, David; Booth, David R.; Carroll, William M.; Lucas, Robyn M.; Kermode, Allan G.; Hart, Prue H.
2017-01-01
It is not clear how the profile of immune cells in peripheral blood differs between patients with clinically isolated syndrome (CIS) and healthy controls (HC). This study aimed to identify a CIS peripheral blood signature that may provide clues for potential immunomodulatory approaches early in disease. Peripheral blood mononuclear cells (PBMCs) were collected from 18 people with CIS, 19 HC and 13 individuals with other demyelinating conditions (ODC) including multiple sclerosis (MS). Individuals with CIS separated into two groups, namely those with early (≤14 days post-diagnostic magnetic resonance imaging (MRI); n = 6) and late (≥27 days; n = 12) blood sampling. Transitional B cells were increased in the blood of CIS patients independently of when blood was taken. However, there were two time-dependent effects found in the late CIS group relative to HC, including decreased CD56bright NK cells, which correlated significantly with time since MRI, and increased CD141+ myeloid dendritic cell (mDC2) frequencies. Higher CD1c+ B cells and lower non-classical monocyte frequencies were characteristic of more recent demyelinating disease activity (ODC and early CIS). Analysing cell populations by time since symptoms (subjective) and diagnostic MRI (objective) may contribute to understanding CIS. PMID:28617321
Trend, Stephanie; Jones, Anderson P; Geldenhuys, Sian; Byrne, Scott N; Fabis-Pedrini, Marzena J; Nolan, David; Booth, David R; Carroll, William M; Lucas, Robyn M; Kermode, Allan G; Hart, Prue H
2017-06-15
It is not clear how the profile of immune cells in peripheral blood differs between patients with clinically isolated syndrome (CIS) and healthy controls (HC). This study aimed to identify a CIS peripheral blood signature that may provide clues for potential immunomodulatory approaches early in disease. Peripheral blood mononuclear cells (PBMCs) were collected from 18 people with CIS, 19 HC and 13 individuals with other demyelinating conditions (ODC) including multiple sclerosis (MS). Individuals with CIS separated into two groups, namely those with early (≤14 days post-diagnostic magnetic resonance imaging (MRI); n = 6) and late (≥27 days; n = 12) blood sampling. Transitional B cells were increased in the blood of CIS patients independently of when blood was taken. However, there were two time-dependent effects found in the late CIS group relative to HC, including decreased CD56bright NK cells, which correlated significantly with time since MRI, and increased CD141+ myeloid dendritic cell (mDC2) frequencies. Higher CD1c+ B cells and lower non-classical monocyte frequencies were characteristic of more recent demyelinating disease activity (ODC and early CIS). Analysing cell populations by time since symptoms (subjective) and diagnostic MRI (objective) may contribute to understanding CIS.
Xu, Yan; Xie, Jianhui; Chen, Ronghua; Cao, Yu; Ping, Yuan; Xu, Qingwen; Hu, Wei; Wu, Dan; Gu, Lihua; Zhou, Huaigu; Chen, Xin; Zhao, Ziqin; Zhong, Jiang; Li, Rui
2016-01-01
No effective method has been developed to distinguish sperm cells originating from different men in multi-suspect sexual assault cases. Here we combined MACS and FACS to isolate single donor sperm cells from forensic mixture samples including female vaginal epithelial cells and sperm cells from multiple contributors. Sperms from vaginal swab were isolated by MACS using FITC-conjugated A kinase anchor protein 3 (AKAP3) antibody; target individual sperm cells involving two or three donors were separated by FACS using FITC-labeled blood group A/B antigen antibody. This procedure was further tested in two mock multi-suspect sexual assault samples and one practical casework sample. Our results showed that complete single donor STR profiles could be successfully obtained from sperm/epithelial cell and sperm mixtures from two contributors. For unbalanced sperm/epithelial cells and sperm cells mixtures, sensitivity results revealed that target cells could be detected at as low as 1:32 and 1:8 mixed ratios, respectively. Although highly relies on cell number and blood types or secretor status of the individuals, this procedure would still be useful tools for forensic DNA analysis of multi-suspect sexual assault cases by the combined use of FACS and MACS based on sperm-specific AKAP3 antigen and human blood type antigen. PMID:27857155
Albanyan, A; Al-Musa, A; AlNounou, R; Al Zahrani, H; Nasr, R; AlJefri, A; Saleh, M; Malik, A; Masmali, H; Owaidah, T
2015-08-01
Glanzmann thrombasthenia (GT) is a rare inherited platelet disorder that is characterized by spontaneous or postprocedural bleeding. The diagnosis of GT depends on identifying the dysfunction of the platelets. The aim of this study was to compare a whole blood impedance Multiplate analyzer (MEA) with the standard method, light transmission aggregometry (LTA) in diagnosis of GT. Fifteen patients with GT were assessed on MEA and LTA using arachidonic acid (ASPI: 15 mm), (TRAP: 1 mm), collagen (100 μg/mL), ADP (0.2 mm), and ristocetin (Risto: 10 mg/mL). Whole blood samples were collected in sodium citrate and hirudin vacuum, blood collection tubes and tested within 4 h. Platelet-rich plasma was used for LTA using platelet agonists (ristocetin 1.5 mg/mL) (arachidonic acid 0.5 mg/mL) (ADP 2.5 mg/mL) and (collagen 1 mg/mL). The platelet count and PFA-100 results were (average and SD) 319 ± 93 × 10(9) L and 252 ± 34 s, respectively. Flow cytometry analysis showed that all samples are positive for CD42a and CD42b, whereas 9/15 samples were negative for CD61 and CD41. The other six patients had either partial or full expression of CD61/CD41. Aggregation analysis using both methods showed that all samples had no aggregation response to any of the agonists used apart from six samples which, using only the MEA, showed minimal aggregation in response to collagen (average = 14.3 ± 7 μg, which may suggest ability to detect qualitative abnormality of GPIIb/IIIa). These results suggest that the MEA is sensitive for the detection of Glanzmann thrombasthenia. Furthermore, MEA may also be able to differentiate between the subtypes of Glanzmann thrombasthenia. © 2014 John Wiley & Sons Ltd.
Janzen, Nils; Sander, Stefanie; Terhardt, Michael; Steuerwald, Ulrike; Peter, Michael; Das, Anibh M; Sander, Johannes
2011-12-11
Newborn screening for congenital adrenal hyperplasia (CAH) is usually done by quantifying 17α-hydroxyprogesterone using immunoassay. However, this test produces high rates of false positive results caused by cross reacting steroids. Therefore we have developed a selective and specific method with a short run time (1.25 min) for quantification of 17α-hydroxyprogesterone, 21-deoxycortisol, 11-deoxycortisol, 11-deoxycorticosterone and cortisol from dried blood spots. The extraction procedure is very simple and steroid separation is ensured on a BEH C18 column and an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). Analysis was done in positive ionization mode (ESI+) and recorded in multiple reaction monitoring mode (MRM). The method gave linear results for all steroids over a range of 5-200 (cortisol: 12.5-500)nmol/L with coefficients of regression >0.992. Absolute recovery was >64.1%. Across the analytical range the inter-assay coefficient of variation (CV) was <3%. Newborn blood samples of patients with confirmed 21-CAH and 11-CAH could clearly be distinguished from samples of unaffected newborns falsely positive on immunoassay. The method is not influenced by cross reactions as found on immunoassay. Analysis of dried blood spots shows that this method is sensitive and fast enough to allow rapid analysis and can therefore improve the newborn screening program. Copyright © 2011 Elsevier Inc. All rights reserved.
Wang, Sha-Sha; Thornton, Keith; Kuhn, Andrew M; Nadeau, James G; Hellyer, Tobin J
2003-10-01
The BD ProbeTec ET System is based on isothermal strand displacement amplification (SDA) of target nucleic acid coupled with homogeneous real-time detection using fluorescent probes. We have developed a novel, rapid method using this platform that incorporates a universal detection format for identification of single-nucleotide polymorphisms (SNPs) and other genotypic variations. The system uses a common pair of fluorescent Detector Probes in conjunction with unlabeled allele-specific Adapter Primers and a universal buffer chemistry to permit analysis of multiple SNP loci under generic assay conditions. We used Detector Probes labeled with different dyes to facilitate differentiation of two alternative alleles in a single reaction with no postamplification manipulation. We analyzed six SNPs within the human beta(2)-adrenergic receptor (beta(2)AR) gene, using whole blood, buccal swabs, and urine samples, and compared results with those obtained by DNA sequencing. Unprocessed whole blood was successfully genotyped with as little as 0.1-1 micro L of sample per reaction. All six beta(2)AR assays were able to accommodate >/==" BORDER="0">20 micro L of unprocessed whole blood. For the 14 individuals tested, genotypes determined with the six beta(2)AR assays agreed with DNA sequencing results. SDA-based allelic differentiation on the BD ProbeTec ET System can detect SNPs rapidly, using whole blood, buccal swabs, or urine.
Computational study of a magnetic design to improve the diagnosis of malaria: 2D model
NASA Astrophysics Data System (ADS)
Vyas, Siddharth; Genis, Vladimir; Friedman, Gary
2017-02-01
This paper investigates the feasibility of a cost effective high gradient magnetic separation based device for the detection and identification of malaria parasites in a blood sample. The design utilizes magnetic properties of hemozoin present in malaria-infected red blood cells (mRBCs) in order to separate and concentrate them inside a microfluidic channel slide for easier examination under the microscope. The design consists of a rectangular microfluidic channel with multiple magnetic wires positioned on top of and underneath it along the length of the channel at a small angle with respect to the channel axis. Strong magnetic field gradients, produced by the wires, exert sufficient magnetic forces on the mRBCs in order to separate and concentrate them in a specific region small enough to fit within the microscope field of view at magnifications typically required to identify the malaria parasite type. The feasibility of the device is studied using a model where the trajectories of the mRBCs inside the channel are determined using first-order ordinary differential equations (ODEs) solved numerically using a multistep ODE solver available within MATLAB. The mRBCs trajectories reveal that it is possible to separate and concentrate the mRBCs in less than 5 min, even in cases of very low parasitemia (1-10 parasites/μL of blood) using blood sample volumes of around 3 μL employed today.
Mobilization of Neural Precursors in the Circulating Blood of Patients with Multiple Sclerosis
2012-07-01
circulating blood of patients with multiple sclerosis PRINCIPAL INVESTIGATOR: Ernesto R. Bongarzone, Ph.D... multiple sclerosis 5b. GRANT NUMBER W81XWH-09-1-0427 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER Ernesto R. Bongarzone...NOTES 14. ABSTRACT Relapsing remitting multiple sclerosis (RRMS) is demyelinating disease that affects both men and women and is characterized by
NASA Astrophysics Data System (ADS)
Zhang, Linna; Zhang, Shengzhao; Sun, Meixiu; Li, Hongxiao; Li, Yingxin; Fu, Zhigang; Guan, Yang; Li, Gang; Lin, Ling
2017-03-01
Discrimination of human and nonhuman blood is crucial for import-export ports and inspection and quarantine departments. Current methods are usually destructive, complicated and time-consuming. We had previously demonstrated that visible diffuse reflectance spectroscopy combining PLS-DA method can successfully realize human blood discrimination. In that research, the spectra were measured with the fiber probe under the surface of blood samples. However, open sampling may pollute the blood samples. Virulence factors in blood samples can also endanger inspectors. In this paper, we explored the classification effect with the blood samples measured in the original containers-vacuum blood vessel. Furthermore, we studied the impact of different conditions of blood samples, such as coagulation and hemolysis, on the prediction ability of the discrimination model. The calibration model built with blood samples in different conditions displayed a satisfactory prediction result. This research demonstrated that visible and near-infrared diffuse reflectance spectroscopy method was potential for noncontact discrimination of human blood.
21 CFR 868.1100 - Arterial blood sampling kit.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...
21 CFR 868.1100 - Arterial blood sampling kit.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...
21 CFR 868.1100 - Arterial blood sampling kit.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...
21 CFR 868.1100 - Arterial blood sampling kit.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...
21 CFR 868.1100 - Arterial blood sampling kit.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...
Mirsadeghi, Seiedeh Aghileh; Zakari, Mohamad Pauzi; Yap, Chee Kong; Shahbazi, Azadeh
2011-01-01
The concentration of carcinogenic polycyclic aromatic hydrocarbons (c-PAHs) present in the sediment and water of Peninsular Malaysia as well as in the cockle Anadara granosa was investigated. Samples were extracted and analysed with gas chromatography-mass spectrometry. The concentrations of total carcinogenic polycyclic aromatic hydrocarbons (t-PAHs) were measured between 0.80 +/- 0.04 to 162.96 +/- 14.74 ng/g wet weight (ww) in sediment, between 21.85 +/- 2.18 to 76.2 +/- 10.82 ng/L in water samples and between 3.34 +/- 0.77 to 46.85 +/- 5.50 ng/g ww in the cockle tissue. The risk assessment of probable human carcinogens in the Group B2 PAHs was calculated and assessed in accordance with the standards of the United States Environmental Protection Agency (US EPA). Case I in the toxicity assessment analysed the cancer risk to consumers of Malaysian blood cockle. Case II assessed the risk of cancer from exposure to PAHs from multiple pathways. The average cancer risk of case I and case II were found to be classifiable as unsafe according to the US EPA standard. The cancer risk due to c-PAHs acquired by the ingestion of blood cockle was (8.82 +/- 0.54) x 10-6 to (2.67 +/- 0.06) x 10(-2), higher than the US EPA risk management criterion. The non-cancer risks associated with multiple pathways in Kuala Gula, Kuala Juru and Kuala Perlis were higher than the U.S. EPA safe level, but the non-cancer risk for eating blood cockle was below the level of U.S. EPA concern.
Flores-Chavez, Maria Delmans; Sambri, Vittorio; Schottstedt, Volkmar; Higuera-Escalante, Fernando Aparicio; Roessler, Dieter; Chaves, Monica; Laengin, Tina; Martinez, Alfredo; Fleischer, Bernhard
2018-05-01
Serology is the preferred method to confirm a Chagas disease diagnosis and to screen blood donors. A battery of assays is often required due to the limited accuracy of single assays. The Elecsys Chagas assay is a newly developed, double-antigen sandwich assay for use on the Elecsys and cobas e immunoassay analyzers, intended to identify individuals infected with Trypanosoma cruzi , for diagnosis and screening. The performance of the Elecsys Chagas assay was evaluated in comparison with those of other widely used T. cruzi antibody assays, at multiple sites (Europe/Latin America). Relative sensitivity and specificity were assessed by using samples from blood donors, pregnant women, and hospitalized patients from regions where Chagas disease is endemic and from regions of nonendemicity. The Elecsys Chagas assay had an overall relative sensitivity of 100% ( n = 674). Overall relative specificities were 99.90% ( n = 14,681), 100% ( n = 313), and 100% ( n = 517) for samples from blood donors, pregnant women, and hospitalized patients, respectively. The analytical specificity was 99.83% ( n = 594). The Elecsys Chagas assay detected T. cruzi antibodies in two World Health Organization (WHO) standard T. cruzi reference panels (panels 09/188 and 09/186) at a 1:512 dilution, corresponding to a cutoff sensitivity of approximately 1 mIU/ml. The Elecsys Chagas assay demonstrated robust performance under routine conditions at multiple sites in Europe and Latin America. In contrast to other available Chagas assays, the Elecsys assay uses a reduced number of recombinant T. cruzi antigens, resulting in a significantly smaller number of cross-reactions and improved analytical specificity while being highly sensitive. Copyright © 2018 Flores-Chavez et al.
Sambri, Vittorio; Schottstedt, Volkmar; Higuera-Escalante, Fernando Aparicio; Roessler, Dieter; Chaves, Monica; Laengin, Tina; Martinez, Alfredo; Fleischer, Bernhard
2018-01-01
ABSTRACT Serology is the preferred method to confirm a Chagas disease diagnosis and to screen blood donors. A battery of assays is often required due to the limited accuracy of single assays. The Elecsys Chagas assay is a newly developed, double-antigen sandwich assay for use on the Elecsys and cobas e immunoassay analyzers, intended to identify individuals infected with Trypanosoma cruzi, for diagnosis and screening. The performance of the Elecsys Chagas assay was evaluated in comparison with those of other widely used T. cruzi antibody assays, at multiple sites (Europe/Latin America). Relative sensitivity and specificity were assessed by using samples from blood donors, pregnant women, and hospitalized patients from regions where Chagas disease is endemic and from regions of nonendemicity. The Elecsys Chagas assay had an overall relative sensitivity of 100% (n = 674). Overall relative specificities were 99.90% (n = 14,681), 100% (n = 313), and 100% (n = 517) for samples from blood donors, pregnant women, and hospitalized patients, respectively. The analytical specificity was 99.83% (n = 594). The Elecsys Chagas assay detected T. cruzi antibodies in two World Health Organization (WHO) standard T. cruzi reference panels (panels 09/188 and 09/186) at a 1:512 dilution, corresponding to a cutoff sensitivity of approximately 1 mIU/ml. The Elecsys Chagas assay demonstrated robust performance under routine conditions at multiple sites in Europe and Latin America. In contrast to other available Chagas assays, the Elecsys assay uses a reduced number of recombinant T. cruzi antigens, resulting in a significantly smaller number of cross-reactions and improved analytical specificity while being highly sensitive. PMID:29444836
Landgren, Ola; Zeig-Owens, Rachel; Giricz, Orsolya; Goldfarb, David; Murata, Kaznouri; Thoren, Katie; Ramanathan, Lakshmi; Hultcrantz, Malin; Dogan, Ahmet; Nwankwo, George; Steidl, Ulrich; Pradhan, Kith; Hall, Charles B; Cohen, Hillel W; Jaber, Nadia; Schwartz, Theresa; Crowley, Laura; Crane, Michael; Irby, Shani; Webber, Mayris P; Verma, Amit; Prezant, David J
2018-06-01
The World Trade Center (WTC) attacks on September 11, 2001, created an unprecedented environmental exposure to known and suspected carcinogens suggested to increase the risk of multiple myeloma. Multiple myeloma is consistently preceded by the precursor states of monoclonal gammopathy of undetermined significance (MGUS) and light-chain MGUS, detectable in peripheral blood. To characterize WTC-exposed firefighters with a diagnosis of multiple myeloma and to conduct a screening study for MGUS and light-chain MGUS. Case series of multiple myeloma in firefighters diagnosed between September 11, 2001, and July 1, 2017, together with a seroprevalence study of MGUS in serum samples collected from Fire Department of the City of New York (FDNY) firefighters between December 2013 and October 2015. Participants included all WTC-exposed FDNY white, male firefighters with a confirmed physician diagnosis of multiple myeloma (n = 16) and WTC-exposed FDNY white male firefighters older than 50 years with available serum samples (n = 781). WTC exposure defined as rescue and/or recovery work at the WTC site between September 11, 2001, and July 25, 2002. Multiple myeloma case information, and age-adjusted and age-specific prevalence rates for overall MGUS (ie, MGUS and light-chain MGUS), MGUS, and light-chain MGUS. Sixteen WTC-exposed white male firefighters received a diagnosis of multiple myeloma after September 11, 2001; median age at diagnosis was 57 years (interquartile range, 50-68 years). Serum/urine monoclonal protein isotype/free light-chain data were available for 14 cases; 7 (50%) had light-chain multiple myeloma. In a subset of 7 patients, myeloma cells were assessed for CD20 expression; 5 (71%) were CD20 positive. In the screening study, we assayed peripheral blood from 781 WTC-exposed firefighters. The age-standardized prevalence rate of MGUS and light-chain MGUS combined was 7.63 per 100 persons (95% CI, 5.45-9.81), 1.8-fold higher than rates from the Olmsted County, Minnesota, white male reference population (relative rate, 1.76; 95% CI, 1.34-2.29). The age-standardized prevalence rate of light-chain MGUS was more than 3-fold higher than in the same reference population (relative rate, 3.13; 95% CI, 1.99-4.93). Environmental exposure to the WTC disaster site is associated with myeloma precursor disease (MGUS and light-chain MGUS) and may be a risk factor for the development of multiple myeloma at an earlier age, particularly the light-chain subtype.
Cheung, Chi Yuen; van der Heijden, Jaques; Hoogtanders, Karin; Christiaans, Maarten; Liu, Yan Lun; Chan, Yiu Han; Choi, Koon Shing; van de Plas, Afke; Shek, Chi Chung; Chau, Ka Foon; Li, Chun Sang; van Hooff, Johannes; Stolk, Leo
2008-02-01
Dried blood spot (DBS) sampling and high-performance liquid chromatography tandem-mass spectrometry have been developed in monitoring tacrolimus levels. Our center favors the use of limited sampling strategy and abbreviated formula to estimate the area under concentration-time curve (AUC(0-12)). However, it is inconvenient for patients because they have to wait in the center for blood sampling. We investigated the application of DBS method in tacrolimus level monitoring using limited sampling strategy and abbreviated AUC estimation approach. Duplicate venous samples were obtained at each time point (C(0), C(2), and C(4)). To determine the stability of blood samples, one venous sample was sent to our laboratory immediately. The other duplicate venous samples, together with simultaneous fingerprick blood samples, were sent to the University of Maastricht in the Netherlands. Thirty six patients were recruited and 108 sets of blood samples were collected. There was a highly significant relationship between AUC(0-12), estimated from venous blood samples, and fingerprick blood samples (r(2) = 0.96, P < 0.0001). Moreover, there was an excellent correlation between whole blood venous tacrolimus levels in the two centers (r(2) = 0.97; P < 0.0001). The blood samples were stable after long-distance transport. DBS sampling can be used in centers using limited sampling and abbreviated AUC(0-12) strategy as drug monitoring.
Centrifugal microfluidic platform for ultrasensitive detection of botulinum toxin
Koh, Chung -Yan; Schaff, Ulrich Y.; Sandstone Diagnostics, Livermore, CA; ...
2014-12-18
In this study, we present an innovative centrifugal microfluidic immunoassay platform (SpinDx) to address the urgent biodefense and public health need for ultrasensitive point-of-care/incident detection of botulinum toxin. The simple, sample-to-answer centrifugal microfluidic immunoassay approach is based on binding of toxins to antibody-laden capture particles followed by sedimentation of the particles through a density-media in a microfluidic disk and quantification by laser-induced fluorescence. A blind, head-to-head comparison study of SpinDx versus the gold-standard mouse bioassay demonstrates 100-fold improvement in sensitivity (limit of detection = 0.09 pg/mL), while achieving total sample-to-answer time of <30 min with 2-μL required volume of themore » unprocessed sample. We further demonstrate quantification of botulinum toxin in both exogeneous (human blood and serum spiked with toxins) and endogeneous (serum from mice intoxicated via oral, intranasal, and intravenous routes) samples. SpinDx can analyze, without any sample preparation, multiple sample types including whole blood, serum, and food. It is readily expandable to additional analytes as the assay reagents (i.e., the capture beads and detection antibodies) are disconnected from the disk architecture and the reader, facilitating rapid development of new assays. SpinDx can also serve as a general-purpose immunoassay platform applicable to diagnosis of other conditions and diseases.« less
Leidinger, Petra; Backes, Christina; Rheinheimer, Stefanie; Keller, Andreas; Meese, Eckart
2015-01-01
Circulating microRNAs (miRNAs) from blood are increasingly recognized as biomarker candidates for human diseases. Clinical routine settings frequently include blood sampling in tubes with EDTA as anticoagulant without considering the influence of phlebotomy on the overall miRNA expression pattern. We collected blood samples from six healthy individuals each in an EDTA blood collection tube. Subsequently, the blood was transferred into PAXgeneTM tubes at three different time points, i.e. directly (0 min), 10 min, and 2 h after phlebotomy. As control blood was also directly collected in PAXgeneTM blood RNA tubes that contain a reagent to directly lyse blood cells and stabilize their content. For all six blood donors at the four conditions (24 samples) we analyzed the abundance of 1,205 miRNAs by human Agilent miRNA V16 microarrays. While we found generally a homogenous pattern of the miRNA abundance in all 24 samples, the duration of the EDTA treatment appears to influence the miRNA abundance of specific miRNAs. The most significant changes are observed after longer EDTA exposition. Overall, the impact of the different blood sample conditions on the miRNA pattern was substantially lower than intra-individual variations. While samples belonging to one of the six individuals mostly cluster together, there was no comparable clustering for any of the four tested blood sampling conditions. The most affected miRNA was miR-769-3p that was not detected in any of the six PAXgene blood samples, but in all EDTA 2h samples. Accordingly, hsa-miR-769-3p was also the only miRNA that showed a significantly different abundance between the 4 blood sample conditions by an ANOVA analysis (Benjamini-Hochberg adjusted p-value of 0.003). Validation by qRT-PCR confirmed this finding. The pattern of blood-borne miRNA abundance is rather homogenous between the four tested blood sample conditions of six blood donors. There was a clustering between the miRNA profiles that belong to a specific blood donor, but not between any of the four tested blood sampling conditions. The results show a limited overall impact of the blood sampling conditions on the miRNA pattern. Notwithstanding, the abundance of single miRNAs can be significantly altered by different blood sampling conditions.
Campagnoli, Cesare; Bellantuono, Ilaria; Kumar, Sailesh; Fairbairn, Leslie J; Roberts, Irene; Fisk, Nicholas M
2002-08-01
We recently reported the existence of fetal mesenchymal stem cells in first trimester fetal blood. Here we demonstrate that fetal mesenchymal stem cells from as early as eight weeks of gestation can be retrovirally transduced with 99% efficiency without selection. Circulating fetal mesenchymal stem cells are known to readily expand and differentiate into multiple tissue types both in vitro and in vivo, and might be suitable vehicles for prenatal gene delivery. With advances in early fetal blood sampling techniques, we suggest that genetic disorders causing irreversible damage before birth could be treated in utero in the late first/early second trimester by genetically manipulated autologous fetal stem cells.
Managing a Mycotic Thoracoabdominal Aneurysm: The Importance of Molecular Diagnostics.
Bayliss, Christopher D; Booth, Karen L; Williams, Robin; Dark, John H; Gould, Kate F
2017-11-01
Pneumococcal mycotic aneurysms are rare and associated with significant mortality and morbidity. Early intravenous antibiotic therapy and surgical intervention is the mainstay of treatment. Pneumococci frequently autolyze in blood cultures, making microbiological diagnosis challenging. We present the case of a man in his mid 70s with multiple thoracoabdominal mycotic aneurysms. Surgery was performed to a threatening saccular aortic arch aneurysm. Samples were sent for microbiological analysis and all were culture negative. The samples were then referred for bacterial 16S ribosomal RNA sequencing, which revealed evidence of infection with Streptococcus pneumoniae. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Ehret, Georg B; Ferreira, Teresa; Chasman, Daniel I; Jackson, Anne U; Schmidt, Ellen M; Johnson, Toby; Thorleifsson, Gudmar; Luan, Jian'an; Donnelly, Lousie A; Kanoni, Stavroula; Petersen, Ann-Kristin; Pihur, Vasyl; Strawbridge, Rona J; Shungin, Dmitry; Hughes, Maria F; Meirelles, Osorio; Kaakinen, Marika; Bouatia-Naji, Nabila; Kristiansson, Kati; Shah, Sonia; Kleber, Marcus E; Guo, Xiuqing; Lyytikäinen, Leo-Pekka; Fava, Cristiano; Eriksson, Niclas; Nolte, Ilja M; Magnusson, Patrik K; Salfati, Elias L; Rallidis, Loukianos S; Theusch, Elizabeth; Smith, Andrew J P; Folkersen, Lasse; Witkowska, Kate; Pers, Tune H; Joehanes, Roby; Kim, Stuart K; Lataniotis, Lazaros; Jansen, Rick; Johnson, Andrew D; Warren, Helen; Kim, Young Jin; Zhao, Wei; Wu, Ying; Tayo, Bamidele O; Bochud, Murielle; Absher, Devin; Adair, Linda S; Amin, Najaf; Arking, Dan E; Axelsson, Tomas; Baldassarre, Damiano; Balkau, Beverley; Bandinelli, Stefania; Barnes, Michael R; Barroso, Inês; Bevan, Stephen; Bis, Joshua C; Bjornsdottir, Gyda; Boehnke, Michael; Boerwinkle, Eric; Bonnycastle, Lori L; Boomsma, Dorret I; Bornstein, Stefan R; Brown, Morris J; Burnier, Michel; Cabrera, Claudia P; Chambers, John C; Chang, I-Shou; Cheng, Ching-Yu; Chines, Peter S; Chung, Ren-Hua; Collins, Francis S; Connell, John M; Döring, Angela; Dallongeville, Jean; Danesh, John; de Faire, Ulf; Delgado, Graciela; Dominiczak, Anna F; Doney, Alex S F; Drenos, Fotios; Edkins, Sarah; Eicher, John D; Elosua, Roberto; Enroth, Stefan; Erdmann, Jeanette; Eriksson, Per; Esko, Tonu; Evangelou, Evangelos; Evans, Alun; Fall, Tove; Farrall, Martin; Felix, Janine F; Ferrières, Jean; Ferrucci, Luigi; Fornage, Myriam; Forrester, Terrence; Franceschini, Nora; Duran, Oscar H Franco; Franco-Cereceda, Anders; Fraser, Ross M; Ganesh, Santhi K; Gao, He; Gertow, Karl; Gianfagna, Francesco; Gigante, Bruna; Giulianini, Franco; Goel, Anuj; Goodall, Alison H; Goodarzi, Mark O; Gorski, Mathias; Gräßler, Jürgen; Groves, Christopher; Gudnason, Vilmundur; Gyllensten, Ulf; Hallmans, Göran; Hartikainen, Anna-Liisa; Hassinen, Maija; Havulinna, Aki S; Hayward, Caroline; Hercberg, Serge; Herzig, Karl-Heinz; Hicks, Andrew A; Hingorani, Aroon D; Hirschhorn, Joel N; Hofman, Albert; Holmen, Jostein; Holmen, Oddgeir Lingaas; Hottenga, Jouke-Jan; Howard, Phil; Hsiung, Chao A; Hunt, Steven C; Ikram, M Arfan; Illig, Thomas; Iribarren, Carlos; Jensen, Richard A; Kähönen, Mika; Kang, Hyun; Kathiresan, Sekar; Keating, Brendan J; Khaw, Kay-Tee; Kim, Yun Kyoung; Kim, Eric; Kivimaki, Mika; Klopp, Norman; Kolovou, Genovefa; Komulainen, Pirjo; Kooner, Jaspal S; Kosova, Gulum; Krauss, Ronald M; Kuh, Diana; Kutalik, Zoltan; Kuusisto, Johanna; Kvaløy, Kirsti; Lakka, Timo A; Lee, Nanette R; Lee, I-Te; Lee, Wen-Jane; Levy, Daniel; Li, Xiaohui; Liang, Kae-Woei; Lin, Honghuang; Lin, Li; Lindström, Jaana; Lobbens, Stéphane; Männistö, Satu; Müller, Gabriele; Müller-Nurasyid, Martina; Mach, François; Markus, Hugh S; Marouli, Eirini; McCarthy, Mark I; McKenzie, Colin A; Meneton, Pierre; Menni, Cristina; Metspalu, Andres; Mijatovic, Vladan; Moilanen, Leena; Montasser, May E; Morris, Andrew D; Morrison, Alanna C; Mulas, Antonella; Nagaraja, Ramaiah; Narisu, Narisu; Nikus, Kjell; O'Donnell, Christopher J; O'Reilly, Paul F; Ong, Ken K; Paccaud, Fred; Palmer, Cameron D; Parsa, Afshin; Pedersen, Nancy L; Penninx, Brenda W; Perola, Markus; Peters, Annette; Poulter, Neil; Pramstaller, Peter P; Psaty, Bruce M; Quertermous, Thomas; Rao, Dabeeru C; Rasheed, Asif; Rayner, N William N W R; Renström, Frida; Rettig, Rainer; Rice, Kenneth M; Roberts, Robert; Rose, Lynda M; Rossouw, Jacques; Samani, Nilesh J; Sanna, Serena; Saramies, Jouko; Schunkert, Heribert; Sebert, Sylvain; Sheu, Wayne H-H; Shin, Young-Ah; Sim, Xueling; Smit, Johannes H; Smith, Albert V; Sosa, Maria X; Spector, Tim D; Stančáková, Alena; Stanton, Alice; Stirrups, Kathleen E; Stringham, Heather M; Sundstrom, Johan; Swift, Amy J; Syvänen, Ann-Christine; Tai, E-Shyong; Tanaka, Toshiko; Tarasov, Kirill V; Teumer, Alexander; Thorsteinsdottir, Unnur; Tobin, Martin D; Tremoli, Elena; Uitterlinden, Andre G; Uusitupa, Matti; Vaez, Ahmad; Vaidya, Dhananjay; van Duijn, Cornelia M; van Iperen, Erik P A; Vasan, Ramachandran S; Verwoert, Germaine C; Virtamo, Jarmo; Vitart, Veronique; Voight, Benjamin F; Vollenweider, Peter; Wagner, Aline; Wain, Louise V; Wareham, Nicholas J; Watkins, Hugh; Weder, Alan B; Westra, Harm-Jan; Wilks, Rainford; Wilsgaard, Tom; Wilson, James F; Wong, Tien Y; Yang, Tsun-Po; Yao, Jie; Yengo, Loic; Zhang, Weihua; Zhao, Jing Hua; Zhu, Xiaofeng; Bovet, Pascal; Cooper, Richard S; Mohlke, Karen L; Saleheen, Danish; Lee, Jong-Young; Elliott, Paul; Gierman, Hinco J; Willer, Cristen J; Franke, Lude; Hovingh, G Kees; Taylor, Kent D; Dedoussis, George; Sever, Peter; Wong, Andrew; Lind, Lars; Assimes, Themistocles L; Njølstad, Inger; Schwarz, Peter Eh; Langenberg, Claudia; Snieder, Harold; Caulfield, Mark J; Melander, Olle; Laakso, Markku; Saltevo, Juha; Rauramaa, Rainer; Tuomilehto, Jaakko; Ingelsson, Erik; Lehtimäki, Terho; Hveem, Kristian; Palmas, Walter; März, Winfried; Kumari, Meena; Salomaa, Veikko; Chen, Yii-Der I; Rotter, Jerome I; Froguel, Philippe; Jarvelin, Marjo-Riitta; Lakatta, Edward G; Kuulasmaa, Kari; Franks, Paul W; Hamsten, Anders; Wichmann, H-Erich; Palmer, Colin N A; Stefansson, Kari; Ridker, Paul M; Loos, Ruth J F; Chakravarti, Aravinda; Deloukas, Panos; Morris, Andrew P; Newton-Cheh, Christopher; Munroe, Patricia B
2016-10-01
To dissect the genetic architecture of blood pressure and assess effects on target organ damage, we analyzed 128,272 SNPs from targeted and genome-wide arrays in 201,529 individuals of European ancestry, and genotypes from an additional 140,886 individuals were used for validation. We identified 66 blood pressure-associated loci, of which 17 were new; 15 harbored multiple distinct association signals. The 66 index SNPs were enriched for cis-regulatory elements, particularly in vascular endothelial cells, consistent with a primary role in blood pressure control through modulation of vascular tone across multiple tissues. The 66 index SNPs combined in a risk score showed comparable effects in 64,421 individuals of non-European descent. The 66-SNP blood pressure risk score was significantly associated with target organ damage in multiple tissues but with minor effects in the kidney. Our findings expand current knowledge of blood pressure-related pathways and highlight tissues beyond the classical renal system in blood pressure regulation.
Chasman, Daniel I.; Jackson, Anne U.; Schmidt, Ellen M.; Johnson, Toby; Thorleifsson, Gudmar; Luan, Jian'an; Donnelly, Lousie A.; Kanoni, Stavroula; Petersen, Ann-Kristin; Pihur, Vasyl; Strawbridge, Rona J.; Shungin, Dmitry; Hughes, Maria F.; Meirelles, Osorio; Kaakinen, Marika; Bouatia-Naji, Nabila; Kristiansson, Kati; Shah, Sonia; Kleber, Marcus E.; Guo, Xiuqing; Lyytikäinen, Leo-Pekka; Fava, Cristiano; Eriksson, Niclas; Nolte, Ilja M.; Magnusson, Patrik K.; Salfati, Elias L.; Rallidis, Loukianos S.; Theusch, Elizabeth; Smith, Andrew J.P.; Folkersen, Lasse; Witkowska, Kate; Pers, Tune H.; Joehanes, Roby; Kim, Stuart K.; Lataniotis, Lazaros; Jansen, Rick; Johnson, Andrew D.; Warren, Helen; Kim, Young Jin; Zhao, Wei; Wu, Ying; Tayo, Bamidele O.; Bochud, Murielle; Absher, Devin; Adair, Linda S.; Amin, Najaf; Arking, Dan E.; Axelsson, Tomas; Baldassarre, Damiano; Balkau, Beverley; Bandinelli, Stefania; Barnes, Michael R.; Barroso, Inês; Bevan, Stephen; Bis, Joshua C.; Bjornsdottir, Gyda; Boehnke, Michael; Boerwinkle, Eric; Bonnycastle, Lori L.; Boomsma, Dorret I.; Bornstein, Stefan R.; Brown, Morris J.; Burnier, Michel; Cabrera, Claudia P.; Chambers, John C.; Chang, I-Shou; Cheng, Ching-Yu; Chines, Peter S.; Chung, Ren-Hua; Collins, Francis S.; Connell, John M.; Döring, Angela; Dallongeville, Jean; Danesh, John; de Faire, Ulf; Delgado, Graciela; Dominiczak, Anna F.; Doney, Alex S.F.; Drenos, Fotios; Edkins, Sarah; Eicher, John D.; Elosua, Roberto; Enroth, Stefan; Erdmann, Jeanette; Eriksson, Per; Esko, Tonu; Evangelou, Evangelos; Evans, Alun; Fall, Tove; Farrall, Martin; Felix, Janine F.; Ferrières, Jean; Ferrucci, Luigi; Fornage, Myriam; Forrester, Terrence; Franceschini, Nora; Duran, Oscar H. Franco; Franco-Cereceda, Anders; Fraser, Ross M.; Ganesh, Santhi K.; Gao, He; Gertow, Karl; Gianfagna, Francesco; Gigante, Bruna; Giulianini, Franco; Goel, Anuj; Goodall, Alison H.; Goodarzi, Mark O.; Gorski, Mathias; Gräßler, Jürgen; Groves, Christopher; Gudnason, Vilmundur; Gyllensten, Ulf; Hallmans, Göran; Hartikainen, Anna-Liisa; Hassinen, Maija; Havulinna, Aki S.; Hayward, Caroline; Hercberg, Serge; Herzig, Karl-Heinz; Hicks, Andrew A.; Hingorani, Aroon D.; Hirschhorn, Joel N.; Hofman, Albert; Holmen, Jostein; Holmen, Oddgeir Lingaas; Hottenga, Jouke-Jan; Howard, Phil; Hsiung, Chao A.; Hunt, Steven C.; Ikram, M. Arfan; Illig, Thomas; Iribarren, Carlos; Jensen, Richard A.; Kähönen, Mika; Kang, Hyun; Kathiresan, Sekar; Keating, Brendan J.; Khaw, Kay-Tee; Kim, Yun Kyoung; Kim, Eric; Kivimaki, Mika; Klopp, Norman; Kolovou, Genovefa; Komulainen, Pirjo; Kooner, Jaspal S.; Kosova, Gulum; Krauss, Ronald M.; Kuh, Diana; Kutalik, Zoltan; Kuusisto, Johanna; Kvaløy, Kirsti; Lakka, Timo A; Lee, Nanette R.; Lee, I-Te; Lee, Wen-Jane; Levy, Daniel; Li, Xiaohui; Liang, Kae-Woei; Lin, Honghuang; Lin, Li; Lindström, Jaana; Lobbens, Stéphane; Männistö, Satu; Müller, Gabriele; Müller-Nurasyid, Martina; Mach, François; Markus, Hugh S.; Marouli, Eirini; McCarthy, Mark I.; McKenzie, Colin A.; Meneton, Pierre; Menni, Cristina; Metspalu, Andres; Mijatovic, Vladan; Moilanen, Leena; Montasser, May E.; Morris, Andrew D.; Morrison, Alanna C.; Mulas, Antonella; Nagaraja, Ramaiah; Narisu, Narisu; Nikus, Kjell; O'Donnell, Christopher J.; O'Reilly, Paul F.; Ong, Ken K.; Paccaud, Fred; Palmer, Cameron D.; Parsa, Afshin; Pedersen, Nancy L.; Penninx, Brenda W.; Perola, Markus; Peters, Annette; Poulter, Neil; Pramstaller, Peter P.; Psaty, Bruce M.; Quertermous, Thomas; Rao, Dabeeru C.; Rasheed, Asif; Rayner, N William N.W.R.; Renström, Frida; Rettig, Rainer; Rice, Kenneth M.; Roberts, Robert; Rose, Lynda M.; Rossouw, Jacques; Samani, Nilesh J.; Sanna, Serena; Saramies, Jouko; Schunkert, Heribert; Sebert, Sylvain; Sheu, Wayne H.-H.; Shin, Young-Ah; Sim, Xueling; Smit, Johannes H.; Smith, Albert V.; Sosa, Maria X.; Spector, Tim D.; Stančáková, Alena; Stanton, Alice; Stirrups, Kathleen E.; Stringham, Heather M.; Sundstrom, Johan; Swift, Amy J.; Syvänen, Ann-Christine; Tai, E-Shyong; Tanaka, Toshiko; Tarasov, Kirill V.; Teumer, Alexander; Thorsteinsdottir, Unnur; Tobin, Martin D.; Tremoli, Elena; Uitterlinden, Andre G.; Uusitupa, Matti; Vaez, Ahmad; Vaidya, Dhananjay; van Duijn, Cornelia M.; van Iperen, Erik P.A.; Vasan, Ramachandran S.; Verwoert, Germaine C.; Virtamo, Jarmo; Vitart, Veronique; Voight, Benjamin F.; Vollenweider, Peter; Wagner, Aline; Wain, Louise V.; Wareham, Nicholas J.; Watkins, Hugh; Weder, Alan B.; Westra, Harm-Jan; Wilks, Rainford; Wilsgaard, Tom; Wilson, James F.; Wong, Tien Y.; Yang, Tsun-Po; Yao, Jie; Yengo, Loic; Zhang, Weihua; Zhao, Jing Hua; Zhu, Xiaofeng; Bovet, Pascal; Cooper, Richard S.; Mohlke, Karen L.; Saleheen, Danish; Lee, Jong-Young; Elliott, Paul; Gierman, Hinco J.; Willer, Cristen J.; Franke, Lude; Hovingh, G Kees; Taylor, Kent D.; Dedoussis, George; Sever, Peter; Wong, Andrew; Lind, Lars; Assimes, Themistocles L.; Njølstad, Inger; Schwarz, Peter EH.; Langenberg, Claudia; Snieder, Harold; Caulfield, Mark J.; Melander, Olle; Laakso, Markku; Saltevo, Juha; Rauramaa, Rainer; Tuomilehto, Jaakko; Ingelsson, Erik; Lehtimäki, Terho; Hveem, Kristian; Palmas, Walter; März, Winfried; Kumari, Meena; Salomaa, Veikko; Chen, Yii-Der I.; Rotter, Jerome I.; Froguel, Philippe; Jarvelin, Marjo-Riitta; Lakatta, Edward G.; Kuulasmaa, Kari; Franks, Paul W.; Hamsten, Anders; Wichmann, H.-Erich; Palmer, Colin N.A.; Stefansson, Kari; Ridker, Paul M; Loos, Ruth J.F.; Chakravarti, Aravinda; Deloukas, Panos; Morris, Andrew P.; Newton-Cheh, Christopher; Munroe, Patricia B.
2016-01-01
To dissect the genetic architecture of blood pressure and assess effects on target-organ damage, we analyzed 128,272 SNPs from targeted and genome-wide arrays in 201,529 individuals of European ancestry and genotypes from an additional 140,886 individuals were used for validation. We identified 66 blood pressure loci, of which 17 were novel and 15 harbored multiple distinct association signals. The 66 index SNPs were enriched for cis-regulatory elements, particularly in vascular endothelial cells, consistent with a primary role in blood pressure control through modulation of vascular tone across multiple tissues. The 66 index SNPs combined in a risk score showed comparable effects in 64,421 individuals of non-European descent. The 66-SNP blood pressure risk score was significantly associated with target-organ damage in multiple tissues, with minor effects in the kidney. Our findings expand current knowledge of blood pressure pathways and highlight tissues beyond the classic renal system in blood pressure regulation. PMID:27618452
Phase-sensitive multiple reference optical coherence tomography (Conference Presentation)
NASA Astrophysics Data System (ADS)
Dsouza, Roshan I.; Subhash, Hrebesh; Neuhaus, Kai; Hogan, Josh; Wilson, Carol; Leahy, Martin
2016-03-01
Multiple reference OCT (MR-OCT) is a recently developed novel time-domain OCT platform based on a miniature reference arm optical delay, which utilizes a single miniature actuator and a partial mirror to generate recirculating optical delay for extended axial-scan range. MR-OCT technology promises to fit into a robust and cost-effective design, compatible with integration into consumer-level devices for addressing wide applications in mobile healthcare and biometry applications. Using conventional intensity based OCT processing techniques, the high-resolution structural imaging capability of MR-OCT has been recently demonstrated for various applications including in vivo human samples. In this study, we demonstrate the feasibility of implementing phase based processing with MR-OCT for various functional applications such as Doppler imaging and sensing of blood vessels, and for tissue vibrography applications. The MR-OCT system operates at 1310nm with a spatial resolution of ~26 µm and an axial scan rate of 600Hz. Initial studies show a displacement-sensitivity of ~20 nm to ~120 nm for the first 1 to 9 orders of reflections, respectively with a mirror as test-sample. The corresponding minimum resolvable velocity for these orders are ~2.3 µm/sec and ~15 µm/sec respectively. Data from a chick chorioallantoic membrane (CAM) model will be shown to demonstrate the feasibility of MR-OCT for imaging in-vivo blood flow.
Multiple mutant clones in blood rarely coexist
NASA Astrophysics Data System (ADS)
Dingli, David; Pacheco, Jorge M.; Traulsen, Arne
2008-02-01
Leukemias arise due to mutations in the genome of hematopoietic (blood) cells. Hematopoiesis has a multicompartment architecture, with cells exhibiting different rates of replication and differentiation. At the root of this process, one finds a small number of stem cells, and hence the description of the mutation-selection dynamics of blood cells calls for a stochastic approach. We use stochastic dynamics to investigate to which extent acquired hematopoietic disorders are associated with mutations of single or multiple genes within developing blood cells. Our analysis considers the appearance of mutations both in the stem cell compartment as well as in more committed compartments. We conclude that in the absence of genomic instability, acquired hematopoietic disorders due to mutations in multiple genes are most likely very rare events, as multiple mutations typically require much longer development times compared to those associated with a single mutation.
Ranking of factors determining potassium mass balance in bicarbonate haemodialysis.
Basile, Carlo; Libutti, Pasquale; Lisi, Piero; Teutonico, Annalisa; Vernaglione, Luigi; Casucci, Francesco; Lomonte, Carlo
2015-03-01
One of the most important pathogenetic factors involved in the onset of intradialysis arrhytmias is the alteration in electrolyte concentration, particularly potassium (K(+)). Two studies were performed: Study A was designed to investigate above all the isolated effect of the factor time t on intradialysis K(+) mass balance (K(+)MB): 11 stable prevalent Caucasian anuric patients underwent one standard (∼4 h) and one long-hour (∼8 h) bicarbonate haemodialysis (HD) session. The latter were pair-matched as far as the dialysate and blood volume processed (90 L) and volume of ultrafiltration are concerned. Study B was designed to identify and rank the other factors determining intradialysis K(+)MB: 63 stable prevalent Caucasian anuric patients underwent one 4-h standard bicarbonate HD session. Dialysate K(+) concentration was 2.0 mmol/L in both studies. Blood samples were obtained from the inlet blood tubing immediately before the onset of dialysis and at t60, t120, t180 min and at end of the 4- and 8-h sessions for the measurement of plasma K(+), blood bicarbonates and blood pH. Additional blood samples were obtained at t360 min for the 8 h sessions. Direct dialysate quantification was utilized for K(+)MBs. Direct potentiometry with an ion-selective electrode was used for K(+) measurements. Study A: mean K(+)MBs were significantly higher in the 8-h sessions (4 h: -88.4 ± 23.2 SD mmol versus 8 h: -101.9 ± 32.2 mmol; P = 0.02). Bivariate linear regression analyses showed that only mean plasma K(+), area under the curve (AUC) of the hourly inlet dialyser diffusion concentration gradient of K(+) (hcgAUCK(+)) and AUC of blood bicarbonates and mean blood bicarbonates were significantly related to K(+)MB in both 4- and 8-h sessions. A multiple linear regression output with K(+)MB as dependent variable showed that only mean plasma K(+), hcgAUCK(+) and duration of HD sessions per se remained statistically significant. Study B: mean K(+)MBs were -86.7 ± 22.6 mmol. Bivariate linear regression analyses showed that only mean plasma K(+), hcgAUCK(+) and mean blood bicarbonates were significantly related to K(+)MB. Again, only mean plasma K(+) and hcgAUCK(+) predicted K(+)MB at the multiple linear regression analysis. Our studies enabled to establish the ranking of factors determining intradialysis K(+)MB: plasma K(+) → dialysate K(+) gradient is the main determinant; acid-base balance plays a much less important role. The duration of HD session per se is an independent determinant of K(+)MB. © The Author 2014. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.
Blood specimen labelling errors: Implications for nephrology nursing practice.
Duteau, Jennifer
2014-01-01
Patient safety is the foundation of high-quality health care, as recognized both nationally and worldwide. Patient blood specimen identification is critical in ensuring the delivery of safe and appropriate care. The practice of nephrology nursing involves frequent patient blood specimen withdrawals to treat and monitor kidney disease. A critical review of the literature reveals that incorrect patient identification is one of the major causes of blood specimen labelling errors. Misidentified samples create a serious risk to patient safety leading to multiple specimen withdrawals, delay in diagnosis, misdiagnosis, incorrect treatment, transfusion reactions, increased length of stay and other negative patient outcomes. Barcode technology has been identified as a preferred method for positive patient identification leading to a definitive decrease in blood specimen labelling errors by as much as 83% (Askeland, et al., 2008). The use of a root cause analysis followed by an action plan is one approach to decreasing the occurrence of blood specimen labelling errors. This article will present a review of the evidence-based literature surrounding blood specimen labelling errors, followed by author recommendations for completing a root cause analysis and action plan. A failure modes and effects analysis (FMEA) will be presented as one method to determine root cause, followed by the Ottawa Model of Research Use (OMRU) as a framework for implementation of strategies to reduce blood specimen labelling errors.
NASA Astrophysics Data System (ADS)
Kumar, N.; George, D.; Sajeesh, P.; Manivannan, P. V.; Sen, A. K.
2016-07-01
We report a planar solenoid actuated valveless micropump with multiple inlet-outlet configurations. The self-priming characteristics of the multiple inlet-multiple outlet micropump are studied. The filling dynamics of the micropump chamber during start-up and the effects of fluid viscosity, voltage and frequency on the dynamics are investigated. Numerical simulations for multiple inlet-multiple outlet micropumps are carried out using fluid structure algorithm. With DI water and at 5.0 Vp-p, 20 Hz frequency, the two inlet-two outlet micropump provides a maximum flow rate of 336 μl min-1 and maximum back pressure of 441 Pa. Performance characteristics of the two inlet-two outlet micropump are studied for aqueous fluids of different viscosity. Transport of biological cell lines and diluted blood samples are demonstrated; the flow rate-frequency characteristics are studied. Viability of cells during pumping with multiple inlet multiple outlet configuration is also studied in this work, which shows 100% of cells are viable. Application of the proposed micropump for simultaneous pumping, mixing and distribution of fluids is demonstrated. The proposed integrated, standalone and portable micropump is suitable for drug delivery, lab-on-chip and micro-total-analysis applications.
Analysis of Sequence Data Under Multivariate Trait-Dependent Sampling.
Tao, Ran; Zeng, Donglin; Franceschini, Nora; North, Kari E; Boerwinkle, Eric; Lin, Dan-Yu
2015-06-01
High-throughput DNA sequencing allows for the genotyping of common and rare variants for genetic association studies. At the present time and for the foreseeable future, it is not economically feasible to sequence all individuals in a large cohort. A cost-effective strategy is to sequence those individuals with extreme values of a quantitative trait. We consider the design under which the sampling depends on multiple quantitative traits. Under such trait-dependent sampling, standard linear regression analysis can result in bias of parameter estimation, inflation of type I error, and loss of power. We construct a likelihood function that properly reflects the sampling mechanism and utilizes all available data. We implement a computationally efficient EM algorithm and establish the theoretical properties of the resulting maximum likelihood estimators. Our methods can be used to perform separate inference on each trait or simultaneous inference on multiple traits. We pay special attention to gene-level association tests for rare variants. We demonstrate the superiority of the proposed methods over standard linear regression through extensive simulation studies. We provide applications to the Cohorts for Heart and Aging Research in Genomic Epidemiology Targeted Sequencing Study and the National Heart, Lung, and Blood Institute Exome Sequencing Project.
Multiple metals predict prolactin and thyrotropin (TSH) levels in men
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meeker, John D., E-mail: meekerj@umich.edu; Rossano, Mary G.; Protas, Bridget
2009-10-15
Exposure to a number of metals can affect neuroendocrine and thyroid signaling, which can result in adverse effects on development, behavior, metabolism, reproduction, and other functions. The present study assessed the relationship between metal concentrations in blood and serum prolactin (PRL) and thyrotropin (TSH) levels, markers of dopaminergic, and thyroid function, respectively, among men participating in a study of environmental influences on male reproductive health. Blood samples from 219 men were analyzed for concentrations of 11 metals and serum levels of PRL and TSH. In multiple linear regression models adjusted for age, BMI and smoking, PRL was inversely associated withmore » arsenic, cadmium, copper, lead, manganese, molybdenum, and zinc, but positively associated with chromium. Several of these associations (Cd, Pb, Mo) are consistent with limited studies in humans or animals, and a number of the relationships (Cr, Cu, Pb, Mo) remained when additionally considering multiple metals in the model. Lead and copper were associated with non-monotonic decrease in TSH, while arsenic was associated with a dose-dependent increase in TSH. For arsenic these findings were consistent with recent experimental studies where arsenic inhibited enzymes involved in thyroid hormone synthesis and signaling. More research is needed for a better understanding of the role of metals in neuroendocrine and thyroid function and related health implications.« less
Pre-treatment red blood cell distribution width provides prognostic information in multiple myeloma.
Zhou, Di; Xu, Peipei; Peng, Miaoxin; Shao, Xiaoyan; Wang, Miao; Ouyang, Jian; Chen, Bing
2018-06-01
The red blood cell distribution width (RDW), a credible marker for abnormal erythropoiesis, has recently been studied as a prognostic factor in oncology, but its role in multiple myeloma (MM) hasn't been thoroughly investigated. We performed a retrospective study in 162 patients with multiple myeloma. Categorical parameters were analyzed using Pearson chi-squared test. The Mann-Whitney and Wilcoxon tests were used for group comparisons. Comparisons of repeated samples data were analyzed with the general linear model repeated-measures procedure. The Kaplan-Meier product-limit method was used to determine OS and PFS, and the differences were assessed by the log-rank test. High RDW baseline was significantly associated with indexes including haemoglobin, bone marrow plasma cell infiltration, and cytogenetics risk stratification. After chemotherapy, the overall response rate (ORR) decreased as RDW baseline increased. In 24 patients with high RDW baseline, it was revealed RDW value decreased when patients achieved complete remission (CR), but increased when the disease progressed. The normal-RDW baseline group showed both longer overall survival (OS) and progression-free survival (PFS) than the high-RDW baseline group. Our study suggests pre-treatment RDW level is a prognostic factor in MM and should be regarded as an important parameter for assessment of therapeutic efficiency. Copyright © 2018. Published by Elsevier B.V.
Tierney, Rosemary J; Edwards, Rachel Hood; Sitki-Green, Diane; Croom-Carter, Deborah; Roy, Sushmita; Yao, Qing-Yun; Raab-Traub, Nancy; Rickinson, Alan B
2006-01-15
Recent work using a heteroduplex tracking assay (HTA) to identify resident viral sequences has suggested that patients with infectious mononucleosis (IM) who are undergoing primary Epstein-Barr virus (EBV) infection frequently harbor different EBV strains. Here, we examine samples from patients with IM by use of a new Epstein-Barr nuclear antigen 2 HTA alongside the established latent membrane protein 1 HTA. Coresident allelic sequences were detected in ex vivo blood and throat wash samples from 13 of 14 patients with IM; most patients carried 2 or more type 1 strains, 1 patient carried 2 type 2 strains, and 1 patient carried both virus types. In contrast, coresident strains were detected in only 2 of 14 patients by in vitro B cell transformation, despite screening >20 isolates/patient. We infer that coacquisition of multiple strains is common in patients with IM, although only 1 strain tends to be rescued in vitro; whether nonrescued strains are present in low abundance or are transformation defective remains to be determined.
Bruneau, Michael L; Johnson, Blair T; Huedo-Medina, Tania B; Larson, Kara A; Ash, Garrett I; Pescatello, Linda S
2016-05-01
To meta-analyze candidate gene association studies on the change in blood pressure beyond the immediate post-exercise phase after versus before aerobic exercise. Meta-analysis. A systematic search was conducted. Studies retrieved included acute (short-term or postexercise hypotension) or chronic (long-term or training) aerobic exercise interventions; and blood pressure measured before and after aerobic exercise training, or before and after exercise or control under ambulatory conditions by genotype. Effect sizes were determined for genotype and adjusted for sample features. Qualifying studies (k=17, n=3524) on average included middle-aged, overweight men (44.2%) and women (55.8%) with prehypertension (134.9±11.7/78.6±9.5mmHg). Training interventions (k=12) were performed at 60.4±12.9% of maximum oxygen consumption (VO2max) for 41.9±12.5minsession(-1), 3.6±1.2daysweek(-1) for 15.7±7.6week; and post-exercise hypotension interventions (k=5) were performed at 53.5±14.4% VO2max for 38.5±5.4minsession(-1). Sample characteristics explained 54.2-59.0% of the variability in the blood pressure change after versus before acute exercise or control under ambulatory conditions, and 57.4-67.1% of the variability in the blood pressure change after versus before training (p<0.001). Only angiotensinogen M235T (rs699) associated with the change in diastolic blood pressure after versus before training (R(2)=0.1%, p=0.05), but this association did not remain statistically significant after adjustment for multiple comparisons. Sample characteristics explained most of the variability in the change of BP beyond the immediate post-exercise phase after versus before acute and chronic aerobic exercise. Angiotensinogen M235T (rs699) was the only genetic variant that associated with the change in diastolic blood pressure after versus before training, accounting for <1% of the variance. Copyright © 2015 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Kleber, Christian; Becker, Christopher A; Malysch, Tom; Reinhold, Jens M; Tsitsilonis, Serafeim; Duda, Georg N; Schmidt-Bleek, Katharina; Schaser, Klaus D
2015-07-01
Hemorrhagic shock (hS) interacts with the posttraumatic immune response and fracture healing in multiple trauma. Due to the lack of a long-term survival multiple trauma animal models, no standardized analysis of fracture healing referring the impact of multiple trauma on fracture healing was performed. We propose a new long-term survival (21 days) murine multiple trauma model combining hS (microsurgical cannulation of carotid artery, withdrawl of blood and continuously blood pressure measurement), femoral (osteotomy/external fixation) and tibial fracture (3-point bending technique/antegrade nail). The posttraumatic immune response was measured via IL-6, sIL-6R ELISA. The hS was investigated via macrohemodynamics, blood gas analysis, wet-dry lung ration and histologic analysis of the shock organs. We proposed a new murine long-term survival (21 days) multiple trauma model mimicking clinical relevant injury patterns and previously published human posttraumatic immune response. Based on blood gas analysis and histologic analysis of shock organs we characterized and standardized our murine multiple trauma model. Furthermore, we revealed hemorrhagic shock as a causative factor that triggers sIL-6R formation underscoring the fundamental pathophysiologic role of the transsignaling mechanism in multiple trauma. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Clinical Evaluation of the BD FACSPresto™ Near-Patient CD4 Counter in Kenya
Angira, Francis; Akoth, Benta; Omolo, Paul; Opollo, Valarie; Bornheimer, Scott; Judge, Kevin; Tilahun, Henok; Lu, Beverly; Omana-Zapata, Imelda; Zeh, Clement
2016-01-01
Background The BD FACSPresto™ Near-Patient CD4 Counter was developed to expand HIV/AIDS management in resource-limited settings. It measures absolute CD4 counts (AbsCD4), percent CD4 (%CD4), and hemoglobin (Hb) from a single drop of capillary or venous blood in approximately 23 minutes, with throughput of 10 samples per hour. We assessed the performance of the BD FACSPresto system, evaluating accuracy, stability, linearity, precision, and reference intervals using capillary and venous blood at KEMRI/CDC HIV-research laboratory, Kisumu, Kenya, and precision and linearity at BD Biosciences, California, USA. Methods For accuracy, venous samples were tested using the BD FACSCalibur™ instrument with BD Tritest™ CD3/CD4/CD45 reagent, BD Trucount™ tubes, and BD Multiset™ software for AbsCD4 and %CD4, and the Sysmex™ KX-21N for Hb. Stability studies evaluated duration of staining (18–120-minute incubation), and effects of venous blood storage <6–24 hours post-draw. A normal cohort was tested for reference intervals. Precision covered multiple days, operators, and instruments. Linearity required mixing two pools of samples, to obtain evenly spaced concentrations for AbsCD4, total lymphocytes, and Hb. Results AbsCD4 and %CD4 venous/capillary (N = 189/ N = 162) accuracy results gave Deming regression slopes within 0.97–1.03 and R2 ≥0.96. For Hb, Deming regression results were R2 ≥0.94 and slope ≥0.94 for both venous and capillary samples. Stability varied within 10% 2 hours after staining and for venous blood stored less than 24 hours. Reference intervals results showed that gender—but not age—differences were statistically significant (p<0.05). Precision results had <3.5% coefficient of variation for AbsCD4, %CD4, and Hb, except for low AbsCD4 samples (<6.8%). Linearity was 42–4,897 cells/μL for AbsCD4, 182–11,704 cells/μL for total lymphocytes, and 2–24 g/dL for Hb. Conclusions The BD FACSPresto system provides accurate, precise clinical results for capillary or venous blood samples and is suitable for near-patient CD4 testing. Trial Registration ClinicalTrials.gov NCT02396355 PMID:27483008
Salimnia, Hossein; Lephart, Paul R.; Schreckenberger, Paul; DesJarlais, Sharon M.; Johnson, J. Kristie; Robinson, Gwen; Carroll, Karen C.; Greer, Amy; Morgan, Margie; Chan, Raymond; Loeffelholz, Michael; Valencia-Shelton, Frances; Jenkins, Stephen; Schuetz, Audrey N.; Daly, Judy A.; Barney, Trenda; Hemmert, Andrew; Kanack, Kristen J.
2016-01-01
Sepsis is a major cause of morbidity, mortality, and increased medical expense. Rapid diagnosis improves outcomes and reduces costs. The FilmArray blood culture identification panel (BioFire Diagnostics LLC, Salt Lake City, UT), a highly multiplexed PCR assay, can identify 24 etiologic agents of sepsis (8 Gram-positive, 11 Gram-negative, and 5 yeast species) and three antimicrobial resistance genes (mecA, vanA/B, and blaKPC) from positive blood culture bottles. It provides results in about 1 h with 2 min for assay setup. We present the results of an eight-center trial comparing the sensitivity and specificity of the panel with those of the laboratories' standard phenotypic identification techniques, as well as with molecular methods used to distinguish Acinetobacter baumannii from other members of the A. calcoaceticus-A. baumannii complex and to detect antimicrobial resistance genes. Testing included 2,207 positive aerobic blood culture samples, 1,568 clinical and 639 seeded. Samples were tested fresh or were frozen for later testing within 8 h after the bottles were flagged as positive by an automated blood culture system. At least one organism was detected by the panel in 1,382 (88.1%) of the positive clinical specimens. The others contained primarily off-panel organisms. The panel reported multiple organisms in 81 (5.86%) positive clinical specimens. The unresolved blood culture identification sensitivity for all target detections exceeded 96%, except for Klebsiella oxytoca (92.2%), which achieved 98.3% sensitivity after resolution of an unavoidable phenotypic error. The sensitivity and specificity for vanA/B and blaKPC were 100%; those for mecA were 98.4 and 98.3%, respectively. PMID:26739158
Beer, Lynn A.; Wang, Huan; Tang, Hsin-Yao; Cao, Zhijun; Chang-Wong, Tony; Tanyi, Janos L.; Zhang, Rugang; Liu, Qin; Speicher, David W.
2013-01-01
The most cancer-specific biomarkers in blood are likely to be proteins shed directly by the tumor rather than less specific inflammatory or other host responses. The use of xenograft mouse models together with in-depth proteome analysis for identification of human proteins in the mouse blood is an under-utilized strategy that can clearly identify proteins shed by the tumor. In the current study, 268 human proteins shed into mouse blood from human OVCAR-3 serous tumors were identified based upon human vs. mouse species differences using a four-dimensional plasma proteome fractionation strategy. A multi-step prioritization and verification strategy was subsequently developed to efficiently select some of the most promising biomarkers from this large number of candidates. A key step was parallel analysis of human proteins detected in the tumor supernatant, because substantially greater sequence coverage for many of the human proteins initially detected in the xenograft mouse plasma confirmed assignments as tumor-derived human proteins. Verification of candidate biomarkers in patient sera was facilitated by in-depth, label-free quantitative comparisons of serum pools from patients with ovarian cancer and benign ovarian tumors. The only proteins that advanced to multiple reaction monitoring (MRM) assay development were those that exhibited increases in ovarian cancer patients compared with benign tumor controls. MRM assays were facilely developed for all 11 novel biomarker candidates selected by this process and analysis of larger pools of patient sera suggested that all 11 proteins are promising candidate biomarkers that should be further evaluated on individual patient blood samples. PMID:23544127
Blood transcriptomic diagnosis of pulmonary and extrapulmonary tuberculosis
Roe, Jennifer K; Thomas, Niclas; Gil, Eliza; Best, Katharine; Tsaliki, Evdokia; Morris‑Jones, Stephen; Stafford, Sian; Simpson, Nandi; Witt, Karolina D; Chain, Benjamin; Miller, Robert F; Martineau, Adrian
2016-01-01
BACKGROUND. Novel rapid diagnostics for active tuberculosis (TB) are required to overcome the time delays and inadequate sensitivity of current microbiological tests that are critically dependent on sampling the site of disease. Multiparametric blood transcriptomic signatures of TB have been described as potential diagnostic tests. We sought to identify the best transcript candidates as host biomarkers for active TB, extend the evaluation of their specificity by comparison with other infectious diseases, and to test their performance in both pulmonary and extrapulmonary TB. METHODS. Support vector machine learning, combined with feature selection, was applied to new and previously published blood transcriptional profiles in order to identify the minimal TB‑specific transcriptional signature shared by multiple patient cohorts including pulmonary and extrapulmonary TB, and individuals with and without HIV-1 coinfection. RESULTS. We identified and validated elevated blood basic leucine zipper transcription factor 2 (BATF2) transcript levels as a single sensitive biomarker that discriminated active pulmonary and extrapulmonary TB from healthy individuals, with receiver operating characteristic (ROC) area under the curve (AUC) scores of 0.93 to 0.99 in multiple cohorts of HIV-1–negative individuals, and 0.85 in HIV-1–infected individuals. In addition, we identified and validated a potentially novel 4-gene signature comprising CD177, haptoglobin, immunoglobin J chain, and galectin 10 that discriminated active pulmonary and extrapulmonary TB from other febrile infections, giving ROC AUCs of 0.94 to 1. CONCLUSIONS. Elevated blood BATF2 transcript levels provide a sensitive biomarker that discriminates active TB from healthy individuals, and a potentially novel 4-gene transcriptional signature differentiates between active TB and other infectious diseases in individuals presenting with fever. FUNDING. MRC, Wellcome Trust, Rosetrees Trust, British Lung Foundation, NIHR. PMID:27734027
Blood transcriptomic diagnosis of pulmonary and extrapulmonary tuberculosis.
Roe, Jennifer K; Thomas, Niclas; Gil, Eliza; Best, Katharine; Tsaliki, Evdokia; Morris-Jones, Stephen; Stafford, Sian; Simpson, Nandi; Witt, Karolina D; Chain, Benjamin; Miller, Robert F; Martineau, Adrian; Noursadeghi, Mahdad
2016-10-06
BACKGROUND. Novel rapid diagnostics for active tuberculosis (TB) are required to overcome the time delays and inadequate sensitivity of current microbiological tests that are critically dependent on sampling the site of disease. Multiparametric blood transcriptomic signatures of TB have been described as potential diagnostic tests. We sought to identify the best transcript candidates as host biomarkers for active TB, extend the evaluation of their specificity by comparison with other infectious diseases, and to test their performance in both pulmonary and extrapulmonary TB. METHODS. Support vector machine learning, combined with feature selection, was applied to new and previously published blood transcriptional profiles in order to identify the minimal TB‑specific transcriptional signature shared by multiple patient cohorts including pulmonary and extrapulmonary TB, and individuals with and without HIV-1 coinfection. RESULTS. We identified and validated elevated blood basic leucine zipper transcription factor 2 ( BATF2 ) transcript levels as a single sensitive biomarker that discriminated active pulmonary and extrapulmonary TB from healthy individuals, with receiver operating characteristic (ROC) area under the curve (AUC) scores of 0.93 to 0.99 in multiple cohorts of HIV-1-negative individuals, and 0.85 in HIV-1-infected individuals. In addition, we identified and validated a potentially novel 4-gene signature comprising CD177, haptoglobin, immunoglobin J chain, and galectin 10 that discriminated active pulmonary and extrapulmonary TB from other febrile infections, giving ROC AUCs of 0.94 to 1. CONCLUSIONS. Elevated blood BATF2 transcript levels provide a sensitive biomarker that discriminates active TB from healthy individuals, and a potentially novel 4-gene transcriptional signature differentiates between active TB and other infectious diseases in individuals presenting with fever. FUNDING. MRC, Wellcome Trust, Rosetrees Trust, British Lung Foundation, NIHR.
Bjørk, Marie Kjærgaard; Simonsen, Kirsten Wiese; Andersen, David Wederkinck; Dalsgaard, Petur Weihe; Sigurðardóttir, Stella Rögn; Linnet, Kristian; Rasmussen, Brian Schou
2013-03-01
An efficient method for analyzing illegal and medicinal drugs in whole blood using fully automated sample preparation and short ultra-high-performance liquid chromatography-tandem mass spectrometry (MS/MS) run time is presented. A selection of 31 drugs, including amphetamines, cocaine, opioids, and benzodiazepines, was used. In order to increase the efficiency of routine analysis, a robotic system based on automated liquid handling and capable of handling all unit operation for sample preparation was built on a Freedom Evo 200 platform with several add-ons from Tecan and third-party vendors. Solid-phase extraction was performed using Strata X-C plates. Extraction time for 96 samples was less than 3 h. Chromatography was performed using an ACQUITY UPLC system (Waters Corporation, Milford, USA). Analytes were separated on a 100 mm × 2.1 mm, 1.7 μm Acquity UPLC CSH C(18) column using a 6.5 min 0.1 % ammonia (25 %) in water/0.1 % ammonia (25 %) in methanol gradient and quantified by MS/MS (Waters Quattro Premier XE) in multiple-reaction monitoring mode. Full validation, including linearity, precision and trueness, matrix effect, ion suppression/enhancement of co-eluting analytes, recovery, and specificity, was performed. The method was employed successfully in the laboratory and used for routine analysis of forensic material. In combination with tetrahydrocannabinol analysis, the method covered 96 % of cases involving driving under the influence of drugs. The manual labor involved in preparing blood samples, solvents, etc., was reduced to a half an hour per batch. The automated sample preparation setup also minimized human exposure to hazardous materials, provided highly improved ergonomics, and eliminated manual pipetting.
NASA Astrophysics Data System (ADS)
Plotnikova, L. V.; Polyanichko, A. M.; Kobeleva, M. O.; Nikekhin, A. A.; Uspenskaya, M. V.; Kayava, A. V.; Garifullin, A. D.; Voloshin, S. V.
2018-01-01
The serum of patients with multiple myeloma was examined by refractometric methods before and after the course of antitumor therapy. It was found that the amount of protein in the serum of patients with multiple myeloma, determined by the value of the serum refractive index, tended to decrease after the course of treatment. The value of the refractive index of blood serum can be used as an additional criterion for assessing the dynamics of changes in blood-serum properties during antitumor therapy.
Ko, Jina; Bhagwat, Neha; Yee, Stephanie S; Black, Taylor; Redlinger, Colleen; Romeo, Janae; O'Hara, Mark; Raj, Arjun; Carpenter, Erica L; Stanger, Ben Z; Issadore, David
2017-09-12
The use of microtechnology for the highly selective isolation and sensitive detection of circulating tumor cells has shown enormous promise. One challenge for this technology is that the small feature sizes - which are the key to this technology's performance - can result in low sample throughput and susceptibility to clogging. Additionally, conventional molecular analysis of CTCs often requires cells to be taken off-chip for sample preparation and purification before analysis, leading to the loss of rare cells. To address these challenges, we have developed a microchip platform that combines fast, magnetic micropore based negative immunomagnetic selection (>10 mL h -1 ) with rapid on-chip in situ RNA profiling (>100× faster than conventional RNA labeling). This integrated chip can isolate both rare circulating cells and cell clusters directly from whole blood and allow individual cells to be profiled for multiple RNA cancer biomarkers, achieving sample-to-answer in less than 1 hour for 10 mL of whole blood. To demonstrate the power of this approach, we applied our device to the circulating tumor cell based diagnosis of pancreatic cancer. We used a genetically engineered lineage-labeled mouse model of pancreatic cancer (KPCY) to validate the performance of our chip. We show that in a cohort of patient samples (N = 25) that this device can detect and perform in situ RNA analysis on circulating tumor cells in patients with pancreatic cancer, even in those with extremely sparse CTCs (<1 CTC mL -1 of whole blood).
Air bubbles and hemolysis of blood samples during transport by pneumatic tube systems.
Mullins, Garrett R; Bruns, David E
2017-10-01
Transport of blood samples through pneumatic tube systems (PTSs) generates air bubbles in transported blood samples and, with increasing duration of transport, the appearance of hemolysis. We investigated the role of air-bubble formation in PTS-induced hemolysis. Air was introduced into blood samples for 0, 1, 3 or 5min to form air bubbles. Hemolysis in the blood was assessed by (H)-index, lactate dehydrogenase (LD) and potassium in plasma. In an effort to prevent PTS-induced hemolysis, blood sample tubes were completely filled, to prevent air bubble formation, and compared with partially filled samples after PTS transport. We also compared hemolysis in anticoagulated vs clotted blood subjected to PTS transport. As with transport through PTSs, the duration of air bubble formation in blood by a gentle stream of air predicted the extent of hemolysis as measured by H-index (p<0.01), LD (p<0.01), and potassium (p<0.02) in plasma. Removing air space in a blood sample prevented bubble formation and fully protected the blood from PTS-induced hemolysis (p<0.02 vs conventionally filled collection tube). Clotted blood developed less foaming during PTS transport and was partially protected from hemolysis vs anticoagulated blood as indicated by lower LD (p<0.03) in serum than in plasma after PTS sample transport. Prevention of air bubble formation in blood samples during PTS transport protects samples from hemolysis. Copyright © 2017 Elsevier B.V. All rights reserved.
Della Bona, Maria Luisa; Malvagia, Sabrina; Villanelli, Fabio; Giocaliere, Elisa; Ombrone, Daniela; Funghini, Silvia; Filippi, Luca; Cavallaro, Giacomo; Bagnoli, Paola; Guerrini, Renzo; la Marca, Giancarlo
2013-05-05
Propranolol, a non-selective beta blocker drug, is used in young infants and newborns for treating several heart diseases; its pharmacokinetics has been extensively evaluated in adult patients using extrapolation to treat pediatric population. The purpose of the present study was to develop and validate a method to measure propranolol levels in dried blood spots. The analysis was performed by using liquid chromatography/tandem mass spectrometry operating in multiple reaction monitoring mode. The calibration curve in matrix was linear in the concentration range of 2.5-200 μg/L with correlation coefficient r=0.9996. Intra-day and inter-day precisions and biases were less than 8.0% (n=10) and 11.5% (n=10) respectively. The recoveries ranged from 94 to 100% and the matrix effect did not result in a severe signal suppression. Propranolol on dried blood spot showed a good stability at three different temperatures for one month. This paper describes a micromethod for measuring propranolol levels on dried blood spot, which determines a great advantage in neonates or young infants during pharmacokinetic studies because of less invasive sampling and small blood volume required. Copyright © 2013 Elsevier B.V. All rights reserved.
The Comparison of Dietary Behaviors among Rural Controlled and Uncontrolled Hypertensive Patients.
Kamran, Aziz; Shekarchi, Ali Akbar; Sharifian, Elham; Heydari, Heshmatolah
2016-01-01
Nutrition is a dominant peripheral factor in increasing blood pressure; however, little information is available about the nutritional status of hypertensive patients in Iran. This study aimed to compare nutritional behaviors of the rural controlled and uncontrolled hypertensive patients and to determine the predictive power of nutritional behaviors from blood pressure. This cross-sectional study was conducted on 671 rural hypertensive patients, using multistage random sampling method in Ardabil city in 2013. Data were collected by a 3-day food record questionnaire. Nutritional data were extracted by Nutritionist 4 software and analyzed by the SPSS 18 software using Pearson correlation, multiple linear regression, ANOVA, and independent t-test. A significant difference was observed in the means of fat intake, cholesterol, saturated fat, sodium, energy, calcium, vitamin C, fiber, and nutritional knowledge between controlled and uncontrolled groups. In the controlled group, sodium, saturated fats, vitamin C, calcium, and energy intake explained 30.6% of the variations in blood pressure and, in the uncontrolled group, sodium, carbohydrate, fiber intake, and nutritional knowledge explained 83% of the variations in blood pressure. There was a significant difference in the nutritional behavior between the two groups and changes in blood pressure could be explained significantly by nutritional behaviors.
Leidinger, Petra; Backes, Christina; Rheinheimer, Stefanie; Keller, Andreas; Meese, Eckart
2015-01-01
Background Circulating microRNAs (miRNAs) from blood are increasingly recognized as biomarker candidates for human diseases. Clinical routine settings frequently include blood sampling in tubes with EDTA as anticoagulant without considering the influence of phlebotomy on the overall miRNA expression pattern. We collected blood samples from six healthy individuals each in an EDTA blood collection tube. Subsequently, the blood was transferred into PAXgeneTM tubes at three different time points, i.e. directly (0 min), 10 min, and 2 h after phlebotomy. As control blood was also directly collected in PAXgeneTM blood RNA tubes that contain a reagent to directly lyse blood cells and stabilize their content. For all six blood donors at the four conditions (24 samples) we analyzed the abundance of 1,205 miRNAs by human Agilent miRNA V16 microarrays. Results While we found generally a homogenous pattern of the miRNA abundance in all 24 samples, the duration of the EDTA treatment appears to influence the miRNA abundance of specific miRNAs. The most significant changes are observed after longer EDTA exposition. Overall, the impact of the different blood sample conditions on the miRNA pattern was substantially lower than intra-individual variations. While samples belonging to one of the six individuals mostly cluster together, there was no comparable clustering for any of the four tested blood sampling conditions. The most affected miRNA was miR-769-3p that was not detected in any of the six PAXgene blood samples, but in all EDTA 2h samples. Accordingly, hsa-miR-769-3p was also the only miRNA that showed a significantly different abundance between the 4 blood sample conditions by an ANOVA analysis (Benjamini-Hochberg adjusted p-value of 0.003). Validation by qRT-PCR confirmed this finding. Conclusion The pattern of blood-borne miRNA abundance is rather homogenous between the four tested blood sample conditions of six blood donors. There was a clustering between the miRNA profiles that belong to a specific blood donor, but not between any of the four tested blood sampling conditions. The results show a limited overall impact of the blood sampling conditions on the miRNA pattern. Notwithstanding, the abundance of single miRNAs can be significantly altered by different blood sampling conditions. PMID:26599228
Safari-Alighiarloo, Nahid; Taghizadeh, Mohammad; Tabatabaei, Seyyed Mohammad; Namaki, Saeed
2016-01-01
Background The involvement of multiple genes and missing heritability, which are dominant in complex diseases such as multiple sclerosis (MS), entail using network biology to better elucidate their molecular basis and genetic factors. We therefore aimed to integrate interactome (protein–protein interaction (PPI)) and transcriptomes data to construct and analyze PPI networks for MS disease. Methods Gene expression profiles in paired cerebrospinal fluid (CSF) and peripheral blood mononuclear cells (PBMCs) samples from MS patients, sampled in relapse or remission and controls, were analyzed. Differentially expressed genes which determined only in CSF (MS vs. control) and PBMCs (relapse vs. remission) separately integrated with PPI data to construct the Query-Query PPI (QQPPI) networks. The networks were further analyzed to investigate more central genes, functional modules and complexes involved in MS progression. Results The networks were analyzed and high centrality genes were identified. Exploration of functional modules and complexes showed that the majority of high centrality genes incorporated in biological pathways driving MS pathogenesis. Proteasome and spliceosome were also noticeable in enriched pathways in PBMCs (relapse vs. remission) which were identified by both modularity and clique analyses. Finally, STK4, RB1, CDKN1A, CDK1, RAC1, EZH2, SDCBP genes in CSF (MS vs. control) and CDC37, MAP3K3, MYC genes in PBMCs (relapse vs. remission) were identified as potential candidate genes for MS, which were the more central genes involved in biological pathways. Discussion This study showed that network-based analysis could explicate the complex interplay between biological processes underlying MS. Furthermore, an experimental validation of candidate genes can lead to identification of potential therapeutic targets. PMID:28028462
Effects of feeding and fasting on wolf blood and urine characteristics
DelGiudice, G.D.; Seal, U.S.; Mech, L.D.
1987-01-01
Feeding and fasting trials were conducted with 2 groups (A and B) of 4 gray wolves (Canis lupus) each during January 1980. The groups were fed for 9 days and fasted for 10 days in a cross-over design. Blood and urine samples and weight data were collected every 2-3 days during each trial. Hemoglobin (Hb) concentrations, red blood cell (RBC) counts, and hematocrits (HCT) were elevated in both groups during fasting. White blood cell (WBC) counts, serum urea nitrogen (SUN), triiodothyronine (T3), and insulin concentrations decreased during fasting in Groups A and B. Mean corpuscular hemoglobin concentration (MCHC), serum cholesterol, triglyceride, and iron (Fe) concentrations were diminished in fasted Group A wolves compared to fed Group B. Creatine phosphokinase (CPK) concentrations were elevated in fed Group A wolves. Serum creatinine (C) concentrations were reduced in both groups during feeding. Urinary urea: creatinine (U:C), potassium:creatine (K:C), and sodium:creatinine (Na:C, pooled Group A and B data) ratios decreased in fasted wolves. Differences were not found between fed and fasted wolves for mean corpuscular volume (MCV), serum cortisol, glucose, calcium (Ca), bilirubin, serum glutamate-oxaloacetate transaminase (SGOT), serum glutamate-pyruvate transaminase (SGOT), serum glutamate-pyruvate transaminase (SGPT), alkaline phosphatase, and luteinizing hormone (LH) concentrations, total iron binding capacity (TIBC), and urinary calcium: creatine (Ca:C) ratios. Analysis of multiple blood or urine samples collected from free-ranging wolves would be useful in enabling researches and managers to identify the nutritional status and general health of wolves over time.
Coda, Alvin B; Icen, Murat; Smith, Jason R; Sinha, Animesh A
2012-07-01
There are major gaps in our knowledge regarding the exact mechanisms and genetic basis of psoriasis. To investigate the pathogenesis of psoriasis, gene expression in 10 skin (5 lesional, 5 nonlesional) and 11 blood (6 psoriatic, 5 nonpsoriatic) samples were examined using Affymetrix HG-U95A microarrays. We detected 535 (425 upregulated, 110 downregulated) DEGs in lesional skin at 1% false discovery rate (FDR). Combining nine microarray studies comparing lesional and nonlesional psoriatic skin, 34.5% of dysregulated genes were overlapped in multiple studies. We further identified 20 skin and 2 blood associated transcriptional "hot spots" at specified genomic locations. At 5% FDR, 11.8% skin and 10.4% blood DEGs in our study mapped to one of the 12 PSORS loci. DEGs that overlap with PSORS loci may offer prioritized targets for downstream genetic fine mapping studies. Novel DEG "hot spots" may provide new targets for defining susceptibility loci in future studies. Copyright © 2012 Elsevier Inc. All rights reserved.
Factors affecting blood sample haemolysis: a cross-sectional study.
Barnard, Ed B G; Potter, David L; Ayling, Ruth M; Higginson, Ian; Bailey, Andrew G; Smith, Jason E
2016-04-01
To determine the effect of blood sampling through an intravenous catheter compared with a needle in Emergency Department blood sampling. We undertook a prospective, cross-sectional study in a UK university teaching hospital Emergency Department. A convenience sample of 985 patients who required blood sampling via venepuncture was collected. A total of 844 complete sets of data were analysed. The median age was 63 years, and 57% of patients were male. The primary outcome measure was the incidence of haemolysis in blood samples obtained via a needle compared with samples obtained via an intravenous catheter. Secondary outcome measures defined the effect on sample haemolysis of the side of the patient the sample was obtained from, the anatomical location of sampling, the perceived difficulty in obtaining the sample, the order of sample tubes collected, estimated tourniquet time and bench time. Data were analysed with logistic regression, and expressed as odds ratios (95% confidence intervals; P-values). Blood samples obtained through an intravenous catheter were more likely to be haemolysed than those obtained via a needle, odds ratio 5.63 (95% confidence interval 2.49-12.73; P<0.001). Blood sampling via an intravenous catheter was significantly associated with an increase in the likelihood of sample haemolysis compared with sampling with a needle. Wherever practicable, blood samples should be obtained via a needle in preference to an intravenous catheter. Future research should include both an economic evaluation, and staff and patient satisfaction of separating blood sampling and intravenous catheter placement.
Junaid, Muhammad; Hashmi, Muhammad Zaffar; Malik, Riffat Naseem
2016-09-01
The study aimed to monitor heavy metal (chromium, Cr; cadmium, Cd; nickel, Ni; copper, Cu; lead, Pb; iron, Fe; manganese, Mn; and zinc, Zn) footprints in biological matrices (urine, whole blood, saliva, and hair), as well as in indoor industrial dust samples, and their toxic effects on oxidative stress and health risks in exposed workers. Overall, blood, urine, and saliva samples exhibited significantly higher concentrations of toxic metals in exposed workers (Cr; blood 16.30 μg/L, urine 58.15 μg/L, saliva 5.28 μg/L) than the control samples (Cr; blood 5.48 μg/L, urine 4.47 μg/L, saliva 2.46 μg/L). Indoor industrial dust samples also reported to have elevated heavy metal concentrations, as an example, Cr quantified with concentration of 299 mg/kg of dust, i.e., more than twice the level of Cr in household dust (136 mg/kg). Superoxide dismutase (SOD) level presented significant positive correlation (p ≤ 0.01) with Cr, Zn, and Cd (Cr > Zn > Cd) which is an indication of heavy metal's associated raised oxidative stress in exposed workers. Elevated average daily intake (ADI) of heavy metals resulted in cumulative hazard quotient (HQ) range of 2.97-18.88 in workers of different surgical units; this is an alarming situation of health risk implications. Principal component analysis-multiple linear regression (PCA-MLR)-based pie charts represent that polishing and cutting sections exhibited highest metal inputs to the biological and environmental matrices than other sources. Heavy metal concentrations in biological matrices and dust samples showed a significant positive correlation between Cr in dust, urine, and saliva samples. Current study will help to generate comprehensive base line data of heavy metal status in biomatrices and dust from scientifically ignored industrial sector. Our findings can play vital role for health departments and industrial environmental management system (EMS) authorities in policy making and implementation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gulson, Brian, E-mail: brian.gulson@mq.edu.au; CSIRO Earth Science and Resource Engineering, North Ryde NSW 2113; Anderson, Phil
Background: As part of the only national survey of lead in Australian children, which was undertaken in 1996, lead isotopic and lead concentration measurements were obtained from children from 24 dwellings whose blood lead levels were ≥15 µg/dL in an attempt to determine the source(s) of their elevated blood lead. Comparisons were made with data for six children with lower blood lead levels (<10 µg/dL). Methods: Thermal ionisation and isotope dilution mass spectrometry were used to determine high precision lead isotopic ratios ({sup 208}Pb/{sup 206}Pb, {sup 207}Pb/{sup 206}Pb and {sup 206}Pb/{sup 204}Pb) and lead concentrations in blood, dust from floormore » wipes, soil, drinking water and paint (where available). Evaluation of associations between blood and the environmental samples was based on the analysis of individual cases, and Pearson correlations and multiple regression analyses based on the whole dataset. Results and discussion: The correlations showed an association for isotopic ratios in blood and wipes (r=0.52, 95% CI 0.19–0.74), blood and soil (r=0.33, 95% CI −0.05–0.62), and blood and paint (r=0.56, 95% CI 0.09–0.83). The regression analyses indicated that the only statistically significant relationship for blood isotopic ratios was with dust wipes (B=0.65, 95% CI 0.35–0.95); there were no significant associations for lead concentrations in blood and environmental samples. There is a strong isotopic correlation of soils and house dust (r=0.53, 95% CI 0.20–0.75) indicative of a common source(s) for lead in soil and house dust. In contrast, as with the regression analyses, no such association is present for bulk lead concentrations (r=−0.003, 95% CI −0.37–0.36), the most common approach employed in source investigations. In evaluation of the isotopic results on a case by case basis, the strongest associations were for dust wipes and blood. -- Highlights: • Children with elevated blood lead ≥15 µg/dL compared with a group with <10 µg/dL. • High precision lead isotopic ratios in blood, house dust wipes, soil, water, paint. • Associations for isotopic measures of blood and dust, blood and soil, blood and paint. • Regressions gave significance for isotopic measures of blood/dust and dust/soil.« less
[Occupational exposure to blood in multiple trauma care].
Wicker, S; Wutzler, S; Schachtrupp, A; Zacharowski, K; Scheller, B
2015-01-01
Trauma care personnel are at risk of occupational exposure to blood-borne pathogens. Little is known regarding compliance with standard precautions or occupational exposure to blood and body fluids among multiple trauma care personnel in Germany. Compliance rates of multiple trauma care personnel in applying standard precautions, knowledge about transmission risks of blood-borne pathogens, perceived risks of acquiring hepatitis B, hepatitis C and human immunodeficiency virus (HIV) and the personal attitude towards testing of the index patient for blood-borne pathogens after a needlestick injury were evaluated. In the context of an advanced multiple trauma training an anonymous questionnaire was administered to the participants. Almost half of the interviewees had sustained a needlestick injury within the last 12 months. Approximately three quarters of the participants were concerned about the risk of HIV and hepatitis. Trauma care personnel had insufficient knowledge of the risk of blood-borne pathogens, overestimated the risk of hepatitis C infection and underused standard precautionary measures. Although there was excellent compliance for using gloves, there was poor compliance in using double gloves (26.4 %), eye protectors (19.7 %) and face masks (15.8 %). The overwhelming majority of multiple trauma care personnel believed it is appropriate to test an index patient for blood-borne pathogens following a needlestick injury. The process of treatment in prehospital settings is less predictable than in other settings in which invasive procedures are performed. Periodic training and awareness programs for trauma care personnel are required to increase the knowledge of occupational infections and the compliance with standard precautions. The legal and ethical aspects of testing an index patient for blood-borne pathogens after a needlestick injury of a healthcare worker have to be clarified in Germany.
Physical fitness of 9 year olds in England: related factors.
Kikuchi, S; Rona, R J; Chinn, S
1995-04-01
To examine the influence of social factors, passive smoking, and other parental health related factors, as well as anthropometric and other measurements on children's cardiorespiratory fitness. This was a cross sectional study. The analysis was based on 22 health areas in England. The subjects were 299 boys and 282 girls aged 8 to 9 years. Parents did not give positive consent for 15% of the eligible sample. A further 25% of the eligible sample did not participate because the cycle-ergometer broke down, study time was insufficient, or they were excluded from the analysis because they were from ethnic minority groups or had missing data on one continuous variable. Cardiorespiratory fitness was determined using the cycle-ergometer test. It was measured in terms of PWC85%-that is, power output per body weight (watt/kg) assessed at 85% of maximum heart rate. The association between children's fitness and biological and social factors was analysed in two stages. Firstly, multiple logistic analysis was used to examine the factors associated with the children's ability to complete the test for at least four minutes. Secondly, multiple linear regression analysis was used to examine the independent association of the factors with PWC85%. In the logistic analysis, shorter children, children with higher blood pressure, and boys with a larger sibship size had poorer fitness. In the multiple regression analysis, only height (p < 0.001) was positively associated, and the sum of skinfold thicknesses at four sites (p = 0.001) was negatively associated with fitness in both sexes. In girls, a positive association was found with pre-exercise peak expiratory flow rate (p < 0.05), and there were negative associations with systolic blood pressure (p < 0.05) and family history of heart attack (p < 0.05). In boys an association was found with skinfold distribution and fitness (p < 0.05), so that children with relatively less body fat were fitter. Social and health behaviour factors such as father's social class, father's employment status, or parents' smoking habits were unrelated to child's fitness. Height and obesity are strongly associated, and systolic blood pressure to a small extent, with children's fitness, but social factors are unrelated.
The role of wild ruminants in the epidemiology of bovine petechial fever.
Snodgrass, D R; Karstad, L H; Cooper, J E
1975-04-01
After experimental inoculation of Cytoecetes ondiri, the agent of bovine petechial fever (BPF), multiplication occurred in impala, bushbuck, Thomson's gazelles and wildebeest, as shown by infectivity studies and clinical findings. Similar attempts to infect one eland failed. As a sequel to this, blood and spleen samples were collected from four species of wild ruminants in an area where BPTF was endemic. Isolations of C. ondiri were made from three of five bushbuck, but not from any other species.
The role of wild ruminants in the epidemiology of bovine petechial fever.
Snodgrass, D. R.; Karstad, L. H.; Cooper, J. E.
1975-01-01
After experimental inoculation of Cytoecetes ondiri, the agent of bovine petechial fever (BPF), multiplication occurred in impala, bushbuck, Thomson's gazelles and wildebeest, as shown by infectivity studies and clinical findings. Similar attempts to infect one eland failed. As a sequel to this, blood and spleen samples were collected from four species of wild ruminants in an area where BPTF was endemic. Isolations of C. ondiri were made from three of five bushbuck, but not from any other species. PMID:1054728
Li, Jing; Guo, Weina; Kaltenboeck, Bernhard; Sachse, Konrad; Yang, Yi; Lu, Guangwu; Zhang, Jilei; Luan, Lu; You, Jinfeng; Huang, Ke; Qiu, Haixiang; Wang, Yaoyao; Li, Min; Yang, Zhangping; Wang, Chengming
2016-09-25
To investigate the prevalence and diversity of bovine Chlamydia spp. in cattle, whole blood from dairy and beef cattle in 11 provinces of China (n=2003) and vaginal swabs, whole blood samples, feces, milk samples from cows in a Yangzhou dairy farm (n=108) were examined using genus- and species-specific PCRs. In cattle from 11 provinces, 2.4% (48/2003) of whole-blood samples were positive for Chlamydia spp., and four Chlamydia species (C. pneumoniae, 41.7%, 20/48; C. psittaci, 22.9%, 11/48; C. gallinacea, 20.8%, 10/48; C. pecorum, 6.3%, 3/48) were identified. In a further study on a Yangzhou dairy farm, 64.8% (70/108) of the cows were positive for Chlamydia spp. C. pecorum was the intestinal endemic species (51/51, 100%), and C. gallinacea was the most frequent species in vaginal swabs (24/27, 88.9%), whole blood buffy coats (5/8, 62.5%) and milk (4/6, 66.7%). C. psittaci and C. pneumoniae were infrequently detected. DNA sequencing of the ompA gene demonstrated the presence of multiple in-herd C. pecorum serovars and single C. gallinacea and C. psittaci serovars which were identical with those of poultry from Yangzhou. This is the first report of C. gallinacea and C. pneumoniae in cattle. Further study is required to address the transmission of Chlamydia spp., in particular of C. gallinacea and C. pneumoniae from their natural hosts, and their potential pathogenic effect on health and production of cattle. Copyright © 2016 Elsevier B.V. All rights reserved.
Adhesive blood microsampling systems for steroid measurement via LC-MS/MS in the rat.
Heussner, Kirsten; Rauh, Manfred; Cordasic, Nada; Menendez-Castro, Carlos; Huebner, Hanna; Ruebner, Matthias; Schmidt, Marius; Hartner, Andrea; Rascher, Wolfgang; Fahlbusch, Fabian B
2017-04-01
Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS) allows for the direct analysis of multiple hormones in a single probe with minimal sample volume. Rodent-based animal studies strongly rely on microsampling, such as the dry blood spot (DBS) method. However, DBS suffers the drawback of hematocrit-dependence (non-volumetric). Hence, novel volumetric microsampling techniques were introduced recently, allowing sampling of fixed accurate volumes. We compared these methods for steroid analysis in the rat to improve inter-system comparability. We analyzed steroid levels in blood using the absorptive microsampling devices Whatman® 903 Protein Saver Cards, Noviplex™ Plasma Prep Cards and the Mitra™ Microsampling device and compared the obtained results to the respective EDTA plasma levels. Quantitative steroid analysis was performed via LC-MS/MS. For the determination of the plasma volume factor for each steroid, their levels in pooled blood samples from each human adults and rats (18weeks) were compared and the transferability of these factors was evaluated in a new set of juvenile (21days) and adult (18weeks) rats. Hematocrit was determined concomitantly. Using these approaches, we were unable to apply one single volume factor for each steroid. Instead, plasma volume factors had to be adjusted for the recovery rate of each steroid and device individually. The tested microsampling systems did not allow the use of one single volume factor for adult and juvenile rats based on an unexpectedly strong hematocrit-dependency and other steroid specific (pre-analytic) factors. Our study provides correction factors for LC-MS/MS steroid analysis of volumetric and non-volumetric microsampling systems in comparison to plasma. It argues for thorough analysis of chromatographic effects before the use of novel volumetric systems for steroid analysis. Copyright © 2017 Elsevier Inc. All rights reserved.
Mbugua, Amos; Maturi, Peter; Rajab, Jamila; Blasczyk, Rainer; Heuft, Hans-Gert
2015-01-01
Background Currently, no data are available on the prevalence of red blood cell (RBC) antibody formation amongst Kenyan patients with multiple transfusion needs, such as patients with sickle cell disease (SCD) or haematological malignancies (HM) and solid (SM) malignancies. Objectives We determined the prevalence and specificities of RBC alloantibodies and autoantibodies in two patient groups with recurrent transfusion demands at Kenyatta National Hospital, Nairobi, Kenya. Method Between February and August 2014, 300 samples from SCD, HM and SM patients were collected and screened for alloantibodies. Samples from 51 healthy blood donors were screened for irregular antibodies and phenotyped. Results Amongst the 228 patients with viable samples (SCD, n = 137; HM, n = 48; SM, n = 43), the median transfusion frequency was two to three events per group, 38 (16.7%) were RBC immunised and 32 (14.0%) had a positive direct antiglobulin test. We identified specific alloantibodies in six patients (2.6%). Four of these six were SCD patients (2.9%) who had specific RBC alloantibodies (anti-Cw, anti-M, anti-Cob, anti-S); amongst HM patients one had anti-K and one had anti-Lea. RBC autoantibody prevalence was 3.1% (7/228). Amongst the healthy blood donors, the Ror, ccD.ee and R2r, ccD.Ee phenotypes accounted for 82% of the Rhesus phenotypes and all were Kell negative. Conclusion The numbers of transfusions and the rates of RBC alloantibodies are low and the most important RBC alloantibody-inducing blood group antigens are relatively homogeneously distributed in this population. A general change in the Kenyatta National Hospital pre-transfusion test regimen is thus not necessary. The current transfusion practice should be reconsidered if transfusion frequencies increase in the future. PMID:28879098
Karinen, Ritva; Vindenes, Vigdis; Hasvold, Inger; Olsen, Kirsten Midtbøen; Christophersen, Asbjørg S; Øiestad, Elisabeth
2015-07-01
Quantitative determination of anti-epileptic drug concentrations is of great importance in forensic toxicology cases. Although the drugs are not usually abused, they are important post-mortem cases where the question of both lack of compliance and accidental or deliberate poisoning might be raised. In addition these drugs can be relevant for driving under the influence cases. A reversed phase ultra-performance liquid chromatography-tandem mass spectrometry method has been developed for the quantitative analysis of the anti-epileptic compounds carbamazepine, carbamazepine-10,11-epoxide, gabapentin, lamotrigine, levetiracetam, oxcarbazepine, 10-OH-carbazepine, phenobarbital, phenytoin, pregabalin, and topiramate in whole blood, using 0.1 mL sample volume with methaqualone as internal standard. Sample preparation was a simple protein precipitation with acetonitrile and methanol. The diluted supernatant was directly injected into the chromatographic system. Separation was performed on an Acquity UPLC® BEH Phenyl column with gradient elution and a mildly alkaline mobile phase. The mass spectrometric detection was performed in positive ion mode, except for phenobarbital, and multiple reaction monitoring was used for drug quantification. The limits of quantification for the different anti-epileptic drugs varied from 0.064 to 1.26 mg/L in blood, within-day and day-to-day relative standard deviations from 2.2 to 14.7% except for phenobarbital. Between-day variation for phenobarbital was 20.4% at the concentration level of 3.5 mg/L. The biases for all compounds were within ±17.5%. The recoveries ranged between 85 and 120%. The corrected matrix effects were 88-106% and 84-110% in ante-mortem and post-mortem whole blood samples, respectively. Copyright © 2014 John Wiley & Sons, Ltd.
Evaluation of AUC(0-4) predictive methods for cyclosporine in kidney transplant patients.
Aoyama, Takahiko; Matsumoto, Yoshiaki; Shimizu, Makiko; Fukuoka, Masamichi; Kimura, Toshimi; Kokubun, Hideya; Yoshida, Kazunari; Yago, Kazuo
2005-05-01
Cyclosporine (CyA) is the most commonly used immunosuppressive agent in patients who undergo kidney transplantation. Dosage adjustment of CyA is usually based on trough levels. Recently, trough levels have been replacing the area under the concentration-time curve during the first 4 h after CyA administration (AUC(0-4)). The aim of this study was to compare the predictive values obtained using three different methods of AUC(0-4) monitoring. AUC(0-4) was calculated from 0 to 4 h in early and stable renal transplant patients using the trapezoidal rule. The predicted AUC(0-4) was calculated using three different methods: the multiple regression equation reported by Uchida et al.; Bayesian estimation for modified population pharmacokinetic parameters reported by Yoshida et al.; and modified population pharmacokinetic parameters reported by Cremers et al. The predicted AUC(0-4) was assessed on the basis of predictive bias, precision, and correlation coefficient. The predicted AUC(0-4) values obtained using three methods through measurement of three blood samples showed small differences in predictive bias, precision, and correlation coefficient. In the prediction of AUC(0-4) measurement of one blood sample from stable renal transplant patients, the performance of the regression equation reported by Uchida depended on sampling time. On the other hand, the performance of Bayesian estimation with modified pharmacokinetic parameters reported by Yoshida through measurement of one blood sample, which is not dependent on sampling time, showed a small difference in the correlation coefficient. The prediction of AUC(0-4) using a regression equation required accurate sampling time. In this study, the prediction of AUC(0-4) using Bayesian estimation did not require accurate sampling time in the AUC(0-4) monitoring of CyA. Thus Bayesian estimation is assumed to be clinically useful in the dosage adjustment of CyA.
Markwalter, Christine F.; Gibson, Lauren E.; Mudenda, Lwiindi; Kimmel, Danielle W.; Mbambara, Saidon; Thuma, Philip E.; Wright, David W.
2018-01-01
Abstract. A rapid, on-bead enzyme-linked immunosorbent assay for Plasmodium lactate dehydrogenase (pLDH) and Plasmodium falciparum histidine-rich protein 2 (HRP2) was adapted for use with dried blood spot (DBS) samples. This assay detected both biomarkers from a single DBS sample with only 45 minutes of total incubation time and detection limits of 600 ± 500 pM (pLDH) and 69 ± 30 pM (HRP2), corresponding to 150 and 24 parasites/μL, respectively. This sensitive and reproducible on-bead detection method was used to quantify pLDH and HRP2 in patient DBS samples from rural Zambia collected at multiple time points after treatment. Biomarker clearance patterns relative to parasite clearance were determined; pLDH clearance followed closely with parasite clearance, whereas most patients maintained detectable levels of HRP2 for 35–52 days after treatment. Furthermore, weak-to-moderate correlations between biomarker concentration and parasite densities were found for both biomarkers. This work demonstrates the utility of the developed assay for epidemiological study and surveillance of malaria. PMID:29557342
Van Looy, Stijn; Verplancke, Thierry; Benoit, Dominique; Hoste, Eric; Van Maele, Georges; De Turck, Filip; Decruyenaere, Johan
2007-01-01
Tacrolimus is an important immunosuppressive drug for organ transplantation patients. It has a narrow therapeutic range, toxic side effects, and a blood concentration with wide intra- and interindividual variability. Hence, it is of the utmost importance to monitor tacrolimus blood concentration, thereby ensuring clinical effect and avoiding toxic side effects. Prediction models for tacrolimus blood concentration can improve clinical care by optimizing monitoring of these concentrations, especially in the initial phase after transplantation during intensive care unit (ICU) stay. This is the first study in the ICU in which support vector machines, as a new data modeling technique, are investigated and tested in their prediction capabilities of tacrolimus blood concentration. Linear support vector regression (SVR) and nonlinear radial basis function (RBF) SVR are compared with multiple linear regression (MLR). Tacrolimus blood concentrations, together with 35 other relevant variables from 50 liver transplantation patients, were extracted from our ICU database. This resulted in a dataset of 457 blood samples, on average between 9 and 10 samples per patient, finally resulting in a database of more than 16,000 data values. Nonlinear RBF SVR, linear SVR, and MLR were performed after selection of clinically relevant input variables and model parameters. Differences between observed and predicted tacrolimus blood concentrations were calculated. Prediction accuracy of the three methods was compared after fivefold cross-validation (Friedman test and Wilcoxon signed rank analysis). Linear SVR and nonlinear RBF SVR had mean absolute differences between observed and predicted tacrolimus blood concentrations of 2.31 ng/ml (standard deviation [SD] 2.47) and 2.38 ng/ml (SD 2.49), respectively. MLR had a mean absolute difference of 2.73 ng/ml (SD 3.79). The difference between linear SVR and MLR was statistically significant (p < 0.001). RBF SVR had the advantage of requiring only 2 input variables to perform this prediction in comparison to 15 and 16 variables needed by linear SVR and MLR, respectively. This is an indication of the superior prediction capability of nonlinear SVR. Prediction of tacrolimus blood concentration with linear and nonlinear SVR was excellent, and accuracy was superior in comparison with an MLR model.
Zhou, Huili; Wu, Guolan; Hu, Xingjiang; Zhu, Meixiang; Zhai, You; Liu, Jian; Shentu, Jianzhong; Wu, Lihua
2015-06-01
A new generic formulation of cycloserine has been developed in China but the pharmacokinetic properties of cycloserine in the Chinese population have not been reported. The aim of our study was to evaluate the pharmacokinetic properties and tolerability of single and multiple oral administrations of cycloserine capsules in healthy Chinese volunteers. This open-label, single- and multiple-dose 3-way crossover study was conducted in healthy Chinese volunteers. Subjects were randomized to receive a single dose of cycloserine (250, 500, or 1000 mg) in separate trial periods, with a 1-week washout between periods. Those allocated to the 250-mg dose continued into the multiple-dose phase, in which they received 250 mg BID for 5 consecutive days. During the single-dose phase, blood samples were collected at regular intervals from 0 to 72 hours after drug administration and the concentrations of cycloserine were determined using LC-MS/MS. During the multiple-dose phase, blood samples were obtained before drug administration on Days 4, 5, and 6 to determine the Cmin at steady state. On Day 6, blood samples were also collected from 0 to 72 hours after drug administration. Pharmacokinetic parameters were estimated using noncompartmental methods. Tolerability was determined using clinical evaluation and monitoring of adverse events. The study enrolled 12 healthy Chinese volunteers (6 men: mean [SD] age = 23.0 [2.6] years, weight = 60.2 [6.2] kg, height = 170.0 [3.0] cm, and body mass index = 20.7 [1.7]; 6 women: mean [SD] age = 25.3 [1.4] years, weight = 51.5 [3.3] kg, height = 160.0 [4.0] cm, and body mass index = 20.1 [0.9]). After administration of a single dose, cycloserine was rapidly absorbed, reaching peak plasma concentrations approximately 0.84 hours after oral administration, and t½ in plasma was about 13.0 hours. The geometric mean (SD) Cmax value increased in proportion to cycloserine dose, from 19.42 (5.89) to 84.76 (21.74) mg/L, and the geometric mean (SD) AUC0-72h value increased from 264.16 (133.37) to 1153.87 (522.16) mg·h/L in the range of a 250- to 1000-mg dose. After administration of multiple doses of cycloserine 250 mg BID, the mean (SD) t½ was 13.56 (4.38) hours, the apparent total clearance of the drug from plasma after oral administration was 1.02 (0.42) L/h, and the apparent volume of distribution was 18.22 (5.25) L, which were comparable with those after single dosing. The accumulation index was 2.19 (0.51), and the fluctuation was 1.05 (0.35). Results of the t tests of Cmax and AUC found no significant differences between the male and female groups. No serious adverse events were reported, and there were no discontinuations due to adverse events. The pharmacokinetic properties of cycloserine were linear at doses from 250 mg to 1000 mg. After multiple doses, the pharmacokinetic properties of cycloserine were consistent with those after single doses. At the doses studied, cycloserine appears to be well tolerated in these healthy volunteers. Chinese Clinical Trials registration: ChiCTR-TTRCC-13003982. Copyright © 2015. Published by Elsevier Inc.
Elevated ambulatory blood pressure in a multi-ethnic population of obese children and adolescents.
Aguilar, Alexandra; Ostrow, Vlady; De Luca, Francesco; Suarez, Elizabeth
2010-06-01
To evaluate the relationship among ambulatory blood pressure (ABP), body mass index (BMI), and homeostasis model assessment (HOMA) in a multi-ethnic population of obese children with clinic blood pressure in the reference range. A total of 43 obese normotensive children (7-17 years old) were recruited. ABP monitoring, oral glucose tolerance test, lipid levels, and urine microalbumin levels were obtained. Fourteen percent of the subjects had elevated 24-hour systolic blood pressure (SBP), 9.3% had elevated daytime SBP, and 32.6 % elevated nighttime SBP. For diastolic blood pressure, 4.7% of the sample had an elevated mean nighttime value. Children with more severe obesity (BMI SD score >2.5) had higher 24-hour and nighttime SBP than children with less severe obesity (BMI SD score < or =2.5). Children with HOMA values in the highest quartile had larger waist circumference and higher clinic blood pressure than children with HOMA values in the lowest quartile, and no difference in the mean ABP values was found in the 2 groups . Multiple linear regression analysis showed that 24-hour and nighttime SBP were significantly correlated with BMI SD score. Obese children with normal clinic blood pressure often exhibit elevated ABP. The risk for ambulatory hypertension appears to be correlated with the degree of obesity. Copyright 2010 Mosby, Inc. All rights reserved.
ACCURACY OF NONINVASIVE ANESTHETIC MONITORING IN THE ANESTHETIZED GIRAFFE (GIRAFFA CAMELOPARDALIS).
Bertelsen, Mads F; Grøndahl, Carsten; Stegmann, George F; Sauer, Cathrine; Secher, Niels H; Hasenkam, J Michael; Damkjær, Mads; Aalkjær, Christian; Wang, Tobias
2017-09-01
This study evaluated the accuracy of pulse oximetry, capnography, and oscillometric blood pressure during general anesthesia in giraffes (Giraffa camelopardalis). Thirty-two giraffes anesthetized for physiologic experiments were instrumented with a pulse oximeter transmittance probe positioned on the tongue and a capnograph sampling line placed at the oral end of the endotracheal tube. A human size 10 blood pressure cuff was placed around the base of the tail, and an indwelling arterial catheter in the auricular artery continuously measured blood pressure. Giraffes were intermittently ventilated using a Hudson demand valve throughout the procedures. Arterial blood for blood gas analysis was collected at multiple time points. Relationships between oxygen saturation as determined by pulse oximetry and arterial oxygen saturation, between arterial carbon dioxide partial pressure and end-tidal carbon dioxide, and between oscillometric pressure and invasive arterial blood pressure were assessed, and the accuracy of pulse oximetry, capnography, and oscillometric blood pressure monitoring evaluated using Bland-Altman analysis. All three noninvasive methods provided relatively poor estimates of the reference values. Receiver operating characteristic curve fitting was used to determine cut-off values for hypoxia, hypocapnia, hypercapnia, and hypotension for dichotomous decision-making. Applying these cut-off values, there was reasonable sensitivity for detection of hypocapnia, hypercapnia, and hypotension, but not for hypoxemia. Noninvasive anesthetic monitoring should be interpreted with caution in giraffes and, ideally, invasive monitoring should be employed.
Initial genome sequencing and analysis of multiple myeloma
Chapman, Michael A.; Lawrence, Michael S.; Keats, Jonathan J.; Cibulskis, Kristian; Sougnez, Carrie; Schinzel, Anna C.; Harview, Christina L.; Brunet, Jean-Philippe; Ahmann, Gregory J.; Adli, Mazhar; Anderson, Kenneth C.; Ardlie, Kristin G.; Auclair, Daniel; Baker, Angela; Bergsagel, P. Leif; Bernstein, Bradley E.; Drier, Yotam; Fonseca, Rafael; Gabriel, Stacey B.; Hofmeister, Craig C.; Jagannath, Sundar; Jakubowiak, Andrzej J.; Krishnan, Amrita; Levy, Joan; Liefeld, Ted; Lonial, Sagar; Mahan, Scott; Mfuko, Bunmi; Monti, Stefano; Perkins, Louise M.; Onofrio, Robb; Pugh, Trevor J.; Vincent Rajkumar, S.; Ramos, Alex H.; Siegel, David S.; Sivachenko, Andrey; Trudel, Suzanne; Vij, Ravi; Voet, Douglas; Winckler, Wendy; Zimmerman, Todd; Carpten, John; Trent, Jeff; Hahn, William C.; Garraway, Levi A.; Meyerson, Matthew; Lander, Eric S.; Getz, Gad; Golub, Todd R.
2013-01-01
Multiple myeloma is an incurable malignancy of plasma cells, and its pathogenesis is poorly understood. Here we report the massively parallel sequencing of 38 tumor genomes and their comparison to matched normal DNAs. Several new and unexpected oncogenic mechanisms were suggested by the pattern of somatic mutation across the dataset. These include the mutation of genes involved in protein translation (seen in nearly half of the patients), genes involved in histone methylation, and genes involved in blood coagulation. In addition, a broader than anticipated role of NF-κB signaling was suggested by mutations in 11 members of the NF-κB pathway. Of potential immediate clinical relevance, activating mutations of the kinase BRAF were observed in 4% of patients, suggesting the evaluation of BRAF inhibitors in multiple myeloma clinical trials. These results indicate that cancer genome sequencing of large collections of samples will yield new insights into cancer not anticipated by existing knowledge. PMID:21430775
Oxytocin Receptor (OXTR) Methylation and Cognition in Psychotic Disorders.
Grove, Tyler B; Burghardt, Kyle J; Kraal, A Zarina; Dougherty, Ryan J; Taylor, Stephan F; Ellingrod, Vicki L
2016-10-01
Previous reports have identified an association between cognitive impairment and genetic variation in psychotic disorders. In particular, this association may be related to abnormal regulation of genes responsible for broad cognitive functions such as the oxytocin receptor (OXTR) . Within psychotic disorders, it is unknown if OXTR methylation, which can have important implications for gene regulation, is related to cognitive function. The current study examined peripheral blood OXTR methylation and general cognition in people with schizophrenia, schizoaffective disorder, and psychotic disorder not otherwise specified (N = 101). Using hierarchical multiple regression analysis, methylation at the Chr3:8767638 site was significantly associated with composite cognitive performance independent of demographic and medication factors while controlling for multiple testing in this combined diagnostic sample (adjusted p = 0.023).
Oxytocin Receptor (OXTR) Methylation and Cognition in Psychotic Disorders
Grove, Tyler B.; Burghardt, Kyle J.; Kraal, A. Zarina; Dougherty, Ryan J.; Taylor, Stephan F.; Ellingrod, Vicki L.
2016-01-01
Previous reports have identified an association between cognitive impairment and genetic variation in psychotic disorders. In particular, this association may be related to abnormal regulation of genes responsible for broad cognitive functions such as the oxytocin receptor (OXTR). Within psychotic disorders, it is unknown if OXTR methylation, which can have important implications for gene regulation, is related to cognitive function. The current study examined peripheral blood OXTR methylation and general cognition in people with schizophrenia, schizoaffective disorder, and psychotic disorder not otherwise specified (N = 101). Using hierarchical multiple regression analysis, methylation at the Chr3:8767638 site was significantly associated with composite cognitive performance independent of demographic and medication factors while controlling for multiple testing in this combined diagnostic sample (adjusted p = 0.023). PMID:27867940
Multiple host-switching of Haemosporidia parasites in bats
Duval, Linda; Robert, Vincent; Csorba, Gabor; Hassanin, Alexandre; Randrianarivelojosia, Milijaona; Walston, Joe; Nhim, Thy; Goodman, Steve M; Ariey, Frédéric
2007-01-01
Background There have been reported cases of host-switching in avian and lizard species of Plasmodium (Apicomplexa, Haemosporidia), as well as in those infecting different primate species. However, no evidence has previously been found for host-swapping between wild birds and mammals. Methods This paper presents the results of the sampling of blood parasites of wild-captured bats from Madagascar and Cambodia. The presence of Haemosporidia infection in these animals is confirmed and cytochrome b gene sequences were used to construct a phylogenetic analysis. Results Results reveal at least three different and independent Haemosporidia evolutionary histories in three different bat lineages from Madagascar and Cambodia. Conclusion Phylogenetic analysis strongly suggests multiple host-switching of Haemosporidia parasites in bats with those from avian and primate hosts. PMID:18045505
Tomographic sensing and localization of fluorescently labeled circulating cells in mice in vivo
NASA Astrophysics Data System (ADS)
Zettergren, Eric; Swamy, Tushar; Runnels, Judith; Lin, Charles P.; Niedre, Mark
2012-07-01
Sensing and enumeration of specific types of circulating cells in small animals is an important problem in many areas of biomedical research. Microscopy-based fluorescence in vivo flow cytometry methods have been developed previously, but these are typically limited to sampling of very small blood volumes, so that very rare circulating cells may escape detection. Recently, we described the development of a ‘diffuse fluorescence flow cytometer’ (DFFC) that allows sampling of much larger blood vessels and therefore circulating blood volumes in the hindlimb, forelimb or tail of a mouse. In this work, we extend this concept by developing and validating a method to tomographically localize circulating fluorescently labeled cells in the cross section of a tissue simulating optical flow phantom and mouse limb. This was achieved using two modulated light sources and an array of six fiber-coupled detectors that allowed rapid, high-sensitivity acquisition of full tomographic data sets at 10 Hz. These were reconstructed into two-dimensional cross-sectional images using Monte Carlo models of light propagation and the randomized algebraic reconstruction technique. We were able to obtain continuous images of moving cells in the sample cross section with 0.5 mm accuracy or better. We first demonstrated this concept in limb-mimicking optical flow photons with up to four flow channels, and then in the tails of mice with fluorescently labeled multiple myeloma cells. This approach increases the overall diagnostic utility of our DFFC instrument.
de Castro, Francine Attié; Simões, Belinda Pinto; Coelho, Eduardo Barbosa; Lanchote, Vera Lucia
2017-06-01
The aim of this study was to evaluate the enantioselective pharmacokinetics of cyclophosphamide and its metabolites 4-hydroxycyclophosphamide and carboxyethylphosphoramide mustard in patients with systemic or multiple sclerosis. Patients with systemic sclerosis (n = 10) or multiple sclerosis (n = 10), genotyped for the allelic variants of CYP2C9*2 and CYP2C9*3 and of the CYP2B6 G516T polymorphism, were treated with 50 mg cyclophosphamide/kg daily for 4 days. Serial blood samples were collected up to 24 hours after administration of the last cyclophosphamide dose. Cyclophosphamide, 4-hydroxycyclophosphamide, and carboxyethylphosphoramide enantiomers were analyzed in plasma samples using liquid chromatography-tandem mass spectrometry coupled to chiral column Chiralcel OD-R or Chiralpak AD-RH. Cytokines IL-2, IL-4, IL-6, IL-8, IL-10, IL- 12p70, IL-17, TNF-α, and INT-δ in the plasma samples collected before cyclophosphamide infusion were analyzed by Milliplex MAP human cytokine/chemokine. Pharmacokinetic parameters showed higher plasma concentrations of (S)-(-)-cyclophosphamide (AUC 215.0 vs 186.2 μg·h/mL for multiple sclerosis patients and 219.1 vs 179.2 μg·h/mL for systemic sclerosis patients) and (R)-4-hydroxycyclophosphamide (AUC 5.6 vs 3.7 μg·h/mL for multiple sclerosis patients and 6.3 vs 5.6 μg·h/mL for systemic sclerosis patients) when compared to their enantiomers in both groups of patients, whereas the pharmacokinetics of the carboxyethylphosphoramide metabolite was not enantioselective. Cytokines' plasma concentrations were similar between multiple and systemic sclerosis groups. The pharmacokinetics of cyclophosphamide is enantioselective in patients with systemic sclerosis and multiple sclerosis, with higher plasma concentrations of the (S)-(-)-cyclophosphamide enantiomer due to the preferential formation of the (R)-4-hydroxycyclophosphamide metabolite. © 2017, The American College of Clinical Pharmacology.
Crayton, Samuel H.; Elias, Andrew; Al-Zaki, Ajlan; Cheng, Zhiliang; Tsourkas, Andrew
2011-01-01
Recent advances in material science and chemistry have led to the development of nanoparticles with diverse physicochemical properties, e.g. size, charge, shape, and surface chemistry. Evaluating which physicochemical properties are best for imaging and therapeutic studies is challenging not only because of the multitude of samples to evaluate, but also because of the large experimental variability associated with in vivo studies (e.g. differences in tumor size, injected dose, subject weight, etc.). To address this issue, we have developed a lanthanide-doped nanoparticle system and analytical method that allows for the quantitative comparison of multiple nanoparticle compositions simultaneously. Specifically, superparamagnetic iron oxide (SPIO) with a range of different sizes and charges were synthesized, each with a unique lanthanide dopant. Following the simultaneous injection of the various SPIO compositions into tumor-bearing mice, inductively coupled plasma mass spectroscopy (ICP-MS) was used to quantitatively and orthogonally assess the concentration of each SPIO composition in serial blood samples and the resected tumor and organs. The method proved generalizable to other nanoparticle platforms, including dendrimers, liposomes, and polymersomes. This approach provides a simple, cost-effective, and non-radiative method to quantitatively compare tumor localization, biodistribution, and blood clearance of more than 10 nanoparticle compositions simultaneously, removing subject-to-subject variability. PMID:22100983
Liu, Yang; Luo, Zhi-Qiang; Lv, Bei-Ran; Zhao, Hai-Yu; Dong, Ling
2016-04-01
The multiple components in Chinese herbal medicines (CHMS) will experience complex absorption and metabolism before entering the blood system. Previous studies often lay emphasis on the components in blood. However, the dynamic and sequential absorption and metabolism process following multi-component oral administration has not been studied. In this study, the in situ closed-loop method combined with LC-MS techniques were employed to study the sequential process of Chuanxiong Rhizoma decoction (RCD). A total of 14 major components were identified in RCD. Among them, ferulic acid, senkyunolide J, senkyunolide I, senkyunolide F, senkyunolide G, and butylidenephthalide were detected in all of the samples, indicating that the six components could be absorbed into blood in prototype. Butylphthalide, E-ligustilide, Z-ligustilide, cnidilide, senkyunolide A and senkyunolide Q were not detected in all the samples, suggesting that the six components may not be absorbed or metabolized before entering the hepatic portal vein. Senkyunolide H could be metabolized by the liver, while senkyunolide M could be metabolized by both liver and intestinal flora. This study clearly demonstrated the changes in the absorption and metabolism process following multi-component oral administration of RCD, so as to convert the static multi-component absorption process into a comprehensive dynamic and continuous absorption and metabolism process. Copyright© by the Chinese Pharmaceutical Association.
Jimmerson, Leah C.; Ray, Michelle L.; Bushman, Lane R.; Anderson, Peter L.; Klein, Brandon; Rower, Joseph E.; Zheng, Jia-Hua; Kiser, Jennifer J.
2014-01-01
Ribavirin (RBV) is a nucleoside analog used to treat a variety of DNA and RNA viruses. RBV undergoes intracellular phosphorylation to a mono- (MP), di- (DP), and triphosphate (TP). The phosphorylated forms have been associated with the mechanisms of antiviral effect observed in vitro, but the intracellular pharmacology of the drug has not been well characterized in vivo. A highly sensitive LC-MS/MS method was developed and validated for the determination of intracellular RBV MP, DP, and TP in multiple cell matrix types. For this method, the individual MP, DP, and TP fractions were isolated from lysed intracellular matrix using strong anion exchange solid phase extraction, dephosphorylated to parent RBV, desalted and concentrated and quantified using LC-MS/MS. The method utilized a stable labeled internal standard (RBV-13C5) which facilitated accuracy (% deviation within ±15%) and precision (coefficient of variation of ≤15%). The quantifiable linear range for the assay was 0.50 to 200 pmol/sample. The method was applied to the measurement of RBV MP, DP, and TP in human peripheral blood mononuclear cells (PBMC), red blood cells (RBC), and dried blood spot (DBS) samples obtained from patients taking RBV for the treatment of chronic Hepatitis C virus infection. PMID:25555148
Farias de Carvalho, S M; Pombo de Oliveira, M S; Thuler, L C; Rios, M; Coelho, R C; Rubim, L C; Silva, E M; Reis, A M; Catovsky, D
1997-07-01
To clarify the seroprevalence of human T-cell lymphotropic virus type I (HTLV-I) among hematologic and cancer patients in the State of Rio de Janeiro, Brazil, we investigated sera from 2430 individuals from the following groups: 152 patients with T-cell diseases, 250 with B-cell disorders, 67 with myeloid leukemia, 41 with Hodgkin's disease, 351 with a history of multiple blood transfusions, 235 patients with solid tumors of different types, and 109 family members of HTLV-I-infected patients. Antibodies to HTLV-I were screened by enzyme-linked immunosorbent assay or particle agglutination assays (or both). Repeatedly reactive samples were tested by Western blot and polymerase chain reaction assay to differentiate HTLV-I from HTLV-II. We found an increased seroprevalence rate of HTLV-I among those with lymphoid malignancies, mainly in T-cell diseases (28.9%), and these results were important in characterizing 44 cases of adult T-cell leukemia/lymphoma. We confirmed the presence of HTLV-I and HTLV-II infections in blood donors (0.4% and 0.1%, respectively), in patients exposed to multiple blood transfusions (10.2% and 0.8%, respectively), and in 30 (27.5%) of 109 family members of HTLV-I- or HTLV-II-infected patients. We also confirmed the high rate occurrence of adult T-cell leukemia/lymphoma among lymphoproliferative disorders in Rio de Janeiro, Brazil.
Predictors of health-related quality of life among low-income midlife women.
Ham, Ok Kyung
2011-02-01
The purpose of this study was to determine whether any of the sociodemographic, biomedical, psychosocial, and medical-care factors independently predict health-related quality of life (HRQoL) among low-income women. Cross-sectional data were used to predict factors that determine HRQoL. A survey was conducted targeting a convenience sample of 200 midlife women. Blood samples were drawn from all participants, who also received a physical examination. Hierarchical multiple regression analysis was used to test the independent effects of each factor. The study found that sociodemographic and psychosocial factors were independently associated with HRQoL. Compared to married women, widowed or divorced women had significantly lower HRQoL, whereas those with higher levels of stress perception and those not performing regular exercise had significantly lower HRQoL (p < .01). The full model accounted for 44.7% of the variance in HRQoL. The HRQoL of low-income midlife women was associated with multiple factors, with stress perception exerting the major influence.
Roy, B C; Krücken, J; Ahmed, J S; Majumder, S; Baumann, M P; Clausen, P-H; Nijhof, A M
2018-04-01
Tick-borne diseases are considered a major hindrance to the health and productive performance of cattle in Bangladesh. To elucidate the epidemiology of tick-borne pathogens (TBPs) in local cattle, a cross-sectional study was performed in the 12 subdistricts (Upazilas) of Mymensingh district in Bangladesh. Blood samples and ticks were collected from 384 clinically healthy cattle kept by 135 farmers from 96 randomly selected villages. DNA extracted from the blood samples was subsequently screened by polymerase chain reaction (PCR) and a Reverse Line Blot (RLB) hybridization assay using an in-house prepared chemiluminescence solution for the presence of Anaplasma, Ehrlichia, Rickettsia, Babesia and Theileria spp. A total of 2,287 ticks were collected from 232 infested cattle (60.4%, 232/384) and identified morphologically as Rhipicephalus (Boophilus) microplus (n = 1,432, 62.6%) and Haemaphysalis bispinosa (n = 855; 37.4%). The RLB results demonstrated that the majority of the cattle (62.2%) were infected with at least one TBP. Theileria orientalis infections were most common (212/384, 55.2%) followed by infections with Anaplasma bovis (137/384, 35.67%), Anaplasma marginale (16/384, 4.17%), Babesia bigemina (4/384, 1.04%) and Babesia bovis (2/384, 0.52%). A previously uncharacterized Anaplasma sp. (Anaplasma sp. Mymensingh) and Babesia sp. (Babesia sp. Mymensingh), which are genetically closely related to Anaplasma platys and B. bigemina, were detected in 50 of 384 (13.0%) and 1 of 384 (0.3%) of the blood samples, respectively. Key risk factors for the occurrence of T. orientalis, A. marginale and Anaplasma sp. Mymensingh were identified. In conclusion, this study revealed that cattle in Mymensingh district are mainly infested with R. microplus and H. bispinosa ticks and may carry multiple TBPs. In addition, two previously uncharacterized pathogens were detected in the bovine blood samples. The pathogenicity of these species remains to be determined. © 2017 Blackwell Verlag GmbH.
PARENTAL STRESS AMONG AFRICAN AMERICAN PARENTS AND GRANDPARENTS
Taylor, Jacquelyn Y.; Washington, Olivia G. M.; Artinian, Nancy T.; Lichtenberg, Peter
2010-01-01
The purpose of this study was to examine the relationships among parental stress, health (defined as level of systolic and diastolic blood pressure and body mass index), childcare characteristics, and social support. The study used a correlational research design and the setting was the metropolitan Detroit area. The sample consisted of 120 hypertensive African American parents and grandparents who reported caring for 1 to 9 children living in the household. Several variables (average diastolic blood pressure, number of children/grandchildren in home, child/grandchild is physically/mentally disabled, ability to decrease stress) were statistically significant predictors of parental stress. These results indicate that the multiple demands of parenting may become a barrier to making life-style changes for parents and grandparents diagnosed with hypertension. Nursing implications of the findings are discussed. PMID:17454289
Parental stress among African American parents and grandparents.
Taylor, Jacquelyn Y; Washington, Olivia G M; Artinian, Nancy T; Lichtenberg, Peter
2007-04-01
The purpose of this study was to examine the relationships among parental stress, health (defined as level of systolic and diastolic blood pressure and body mass index), childcare characteristics, and social support. The study used a correlational research design and the setting was the metropolitan Detroit area. The sample consisted of 120 hypertensive African American parents and grandparents who reported caring for 1 to 9 children living in the household. Several variables (average diastolic blood pressure, number of children/grandchildren in home, child/grandchild is physically/mentally disabled, ability to decrease stress) were statistically significant predictors of parental stress. These results indicate that the multiple demands of parenting may become a barrier to making life-style changes for parents and grandparents diagnosed with hypertension. Nursing implications of the findings are discussed.
Scott, T W; Clark, G G; Lorenz, L H; Amerasinghe, P H; Reiter, P; Edman, J D
1993-01-01
We evaluated a histologic technique for its usefulness in detecting multiple blood feeding by Aedes aegypti (L.) in a single gonotrophic cycle. To standardize the procedure, we carried out a laboratory study in which 166 mosquitoes imbibed two blood meals at known intervals. Eighty percent (78/98) of the multiple meals were detected when the interval between meals was from 1 to < to = 24 h and the time from the second meal to fixation ranged from 0 to 12 hr. At intervals outside this range, only 34% (23/68) of the multiple meals were detected. Overall, 61% (101/166) of the double meals were detected. Examination of 96 engorged Ae. aegypti collected by aspiration from inside houses in San Juan, Puerto Rico, indicated that 50% had imbibed multiple meals. Most wild-caught mosquitoes took their last meal the day before capture, and most multiple feeders fed twice on consecutive days. A dark line of digested blood, or heme, around the first meal and a physical separation between meals were the most useful histologic parameters for detecting multiple feeding in wild Ae. aegypti. An association of multiple feeding with advanced stages of oocyte development suggests that, at the time of collection, most Ae. aegypti from the study site had fed twice in each gonotrophic cycle. We conclude that, although it is labor intensive, histologic examination is an appropriate technique for a longitudinal, community-wide survey of multiple feeding by Ae. aegypti.
Oscillations and Multiple Equilibria in Microvascular Blood Flow.
Karst, Nathaniel J; Storey, Brian D; Geddes, John B
2015-07-01
We investigate the existence of oscillatory dynamics and multiple steady-state flow rates in a network with a simple topology and in vivo microvascular blood flow constitutive laws. Unlike many previous analytic studies, we employ the most biologically relevant models of the physical properties of whole blood. Through a combination of analytic and numeric techniques, we predict in a series of two-parameter bifurcation diagrams a range of dynamical behaviors, including multiple equilibria flow configurations, simple oscillations in volumetric flow rate, and multiple coexistent limit cycles at physically realizable parameters. We show that complexity in network topology is not necessary for complex behaviors to arise and that nonlinear rheology, in particular the plasma skimming effect, is sufficient to support oscillatory dynamics similar to those observed in vivo.
Mess, Jean-Nicholas; Taillon, Marie-Pierre; Côté, Cynthia; Garofolo, Fabio
2012-12-01
Thiorphan, the active metabolite of racecadotril, can undergo oxidation in biological matrices such as blood and plasma. In bioanalysis, a general approach for the stabilization of such a molecule is to derivatize the thiol group to a more stable thioether, often requiring complex handling procedures at the clinical site. In this research, the concept of dried blood spot (DBS) on-card derivatization was evaluated to stabilize thiorphan. DBS cards were in-house pre-treated with 2-bromo-3'-methoxyacetophenone and left to dry prior to blood spotting. Thiorphan was shown to be effectively derivatized to thiorphan-methoxyacetophenone once applied on the in-house pre-treated cards. Thiorphan-methoxyacetophenone was extracted by soaking a 6 mm DBS punch in methanol containing the internal standard (thiorphan-methoxyacetophenone-D₅). Chromatographic separation was achieved on a Waters XBridge C₁₈ column with a gradient elution of 5 mM NH₄HCO₃ and methanol in 2.5 min and detection by ESI(+)/MS/MS. A linear (weighted 1/x²) relationship was obtained over a concentration range of 5.00-600.00 ng/mL. The assay met regulatory guidelines acceptance criteria for sensitivity, selectivity, precision and accuracy, matrix effect, recovery, dilution integrity and multiple stability evaluations. The DBS on-card derivatization has shown to be an easy and reliable alternative form of sample collection for the quantification of thiorphan. Copyright © 2012 John Wiley & Sons, Ltd.
Electric kettles as a source of human lead exposure.
Wigle, D T; Charlebois, E J
1978-01-01
Five hundred and seventy-four households in Ottawa were surveyed to evaluate water boiled in electric kettles as a source of lead exposure. Samples of boiled water exceeded the World Health Organization mandatory limit for drinking water (50 microgram/l) in 42.5% of the households. Excessive lead concentrations were observed in 62.8% of water samples from kettles more than 5 years old. Multiple regression analysis indicated that age, sex, and cigarette smoking habits, but not lead concentration in boiled water, nor weekly consumption of boiled water were significantly associated with blood-lead concentration. Lead exposure from electric kettles may be a significant problem only in infants receiving formula prepared with boiled water.
Meade, Christina S.; Wang, Jianping; Lin, Xiuyun; Wu, Hao; Poppen, Paul J.
2013-01-01
Throughout the 1990s, many villagers in rural China were infected with HIV through commercial plasma/blood donation. These former plasma/blood donors (FPDs) experienced many HIV-related stressors. This study tested a cognitive appraisal model of stress and coping in a sample of HIV-positive adult FPDs. Participants (N = 207) from multiple villages completed a battery of questionnaires assessing HIV-related stress, HIV symptoms, cognitive appraisal, coping behaviors, and psychological distress. Participants reported high levels of HIV-related stress, depression, and anxiety. In a structural equation model, greater HIV-related stress, HIV symptoms, and threat appraisal were directly associated with psychological distress. HIV-related stress was also indirectly associated with psychological distress through threat appraisal. In a second model, coping was found to mediate the relationship between challenge appraisal and psychological distress. Results support the utility of cognitive appraisal theory. Stress management interventions targeting HIV-positive FPDs in China are indicated. PMID:19127424
Power M-mode Doppler (PMD) for observing cerebral blood flow and tracking emboli.
Moehring, Mark A; Spencer, Merrill P
2002-01-01
Difficulties in location of transcranial ultrasound (US) windows and blood flow in cerebral vessels, and unambiguous detection of microemboli, have limited expansion of transcranial Doppler US. We developed a new transcranial Doppler modality, power M-mode Doppler (PMD), for addressing these issues. A 2-MHz digital Doppler (Spencer Technologies TCD100M) having 33 sample gates placed with 2-mm spacing was configured to display Doppler signal power, colored red and blue for directionality, in an M-mode format. The spectrogram from a user-selected depth was displayed simultaneously. This system was then explored on healthy subjects and patients presenting with varying cerebrovascular pathology. PMD facilitated window location and alignment of the US beam to view blood flow from multiple vessels simultaneously, without sound or spectral clues. Microemboli appeared as characteristic sloping high-power tracks in the PMD image. Power M-mode Doppler is a new paradigm facilitating vessel location, diagnosis, monitoring and microembolus detection.
Species differences in hematological values of captive cranes, geese, raptors, and quail
Gee, G.F.; Carpenter, J.W.; Hensler, G.L.
1981-01-01
Hematological and serum chemical constituents of blood were determined for 12 species, including 7 endangered species, of cranes, geese, raptors, and quail in captivity at the Patuxent Wildlife Research Center. Means, standard deviations, analysis of variance by species and sex, and a series of multiple comparisons of means were derived for each parameter investigated. Differences among some species means were observed in all blood parameters except gamma-glutamyl transpeptidase. Although sampled during the reproductively quiescent period, an influence of sex was noted in red blood cell count, hemoglobin, albumin, glucose, cholesterol, serum glutamic oxaloacetic transaminase, Ca, and P. Our data and values reported in literature indicate that most hematological parameters vary among species and, in some cases, according to methods used to determine them. Therefore, baseline data for captive and wild birds should be established by using standard methods, and should be made available to aid others for use in assessing physiological and pathological conditions of these species.
Chromosome Aberrations in Astronauts
NASA Technical Reports Server (NTRS)
George, Kerry A.; Durante, M.; Cucinotta, Francis A.
2007-01-01
A review of currently available data on in vivo induced chromosome damage in the blood lymphocytes of astronauts proves that, after protracted exposure of a few months or more to space radiation, cytogenetic biodosimetry analyses of blood collected within a week or two of return from space provides a reliable estimate of equivalent radiation dose and risk. Recent studies indicate that biodosimetry estimates from single spaceflights lie within the range expected from physical dosimetry and biophysical models, but very large uncertainties are associated with single individual measurements and the total sample population remains low. Retrospective doses may be more difficult to estimate because of the fairly rapid time-dependent loss of "stable" aberrations in blood lymphocytes. Also, biodosimetry estimates from individuals who participate in multiple missions, or very long (interplanetary) missions, may be complicated by an adaptive response to space radiation and/or changes in lymphocyte survival and repopulation. A discussion of published data is presented and specific issues related to space radiation biodosimetry protocols are discussed.
Trötzmüller, Martin; Triebl, Alexander; Ajsic, Amra; Hartler, Jürgen; Köfeler, Harald; Regittnig, Werner
2017-11-21
Multiple-tracer approaches for investigating glucose metabolism in humans usually involve the administration of stable and radioactive glucose tracers and the subsequent determination of tracer enrichments in sampled blood. When using conventional, low-resolution mass spectrometry (LRMS), the number of spectral interferences rises rapidly with the number of stable tracers employed. Thus, in LRMS, both computational effort and statistical uncertainties associated with the correction for spectral interferences limit the number of stable tracers that can be simultaneously employed (usually two). Here we show that these limitations can be overcome by applying high-resolution mass spectrometry (HRMS). The HRMS method presented is based on the use of an Orbitrap mass spectrometer operated at a mass resolution of 100 000 to allow electrospray-generated ions of the deprotonated glucose molecules to be monitored at their exact masses. The tracer enrichment determination in blood plasma is demonstrated for several triple combinations of 13 C- and 2 H-labeled glucose tracers (e.g., [1- 2 H 1 ]-, [6,6- 2 H 2 ]-, [1,6- 13 C 2 ]glucose). For each combination it is shown that ions arising from 2 H-labeled tracers are completely differentiated from those arising from 13 C-labeled tracers, thereby allowing the enrichment of a tracer to be simply calculated from the observed ion intensities using a standard curve with curve parameters unaffected by the presence of other tracers. For each tracer, the HRMS method exhibits low limits of detection and good repeatability in the tested 0.1-15.0% enrichment range. Additionally, due to short sample preparation and analysis times, the method is well-suited for high-throughput determination of multiple glucose tracer enrichments in plasma samples.
Flores, Manuela F; Montenegro, Marlon M; Furtado, Mariana V; Polanczyk, Carisi A; Rösing, Cassiano K; Haas, Alex N
2014-04-01
There are scarce data on the impact of the periodontal condition in the control of biomarkers in patients with cardiovascular disease (CVD). The aim of this study is to assess whether periodontal inflammation and tissue breakdown are associated with C-reactive protein (CRP) and lipids in patients with stable heart disease. This cross-sectional study included 93 patients with stable coronary artery disease (57 males; mean age: 63.5 ± 9.8 years) who were in outpatient care for at least 6 months. After applying a structured questionnaire, periodontal examinations were performed by two calibrated periodontists in six sites per tooth at all teeth. Blood samples were collected from patients on the day of periodontal examination to determine levels of CRP, lipids, and glycated hemoglobin. Multiple linear regression models were fitted to evaluate the association among different periodontal and blood parameters controlling for sex, body mass index, glycated hemoglobin, use of oral hypoglycemic drugs, and smoking. Overall, the sample presented high levels of periodontal inflammation and tissue breakdown. Unadjusted mean concentrations of triglycerides (TGs), very-low-density lipoprotein cholesterol, and glucose were significantly higher in individuals with severe periodontitis. When multiple linear regression models were applied, number of teeth with clinical attachment loss ≥6 mm and presence of severe periodontitis were significantly associated with higher CRP concentrations. Bleeding on probing was significantly associated with TGs, total cholesterol, and non-high-density lipoprotein cholesterol. In this sample of patients with stable CVD, current periodontal inflammation and tissue breakdown are associated with cardiovascular inflammatory markers, such as CRP and lipid profile.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Byung-Kook; Kim, Yangho, E-mail: yanghokm@nuri.net
Introduction: We present data from the Korean National Health and Nutrition Examination Survey 2008-2009 on the distribution of blood cadmium levels and their association with iron deficiency in a representative sample of the adult Korean population. Methods: Serum ferritin was categorized into three levels: low (serum ferritin <15.0 {mu}g/L), low normal (15.0-30.0 {mu}g/L for women and 15.0-50.0 for men), and normal ({>=}30.0 {mu}g/L for women and {>=}50.0 for men), and its association with blood cadmium level was assessed after adjustment for various demographic and lifestyle factors. Results: Geometric means of blood cadmium in the low serum ferritin group in women,more » men, and all participants were significantly higher than in the normal group. Additionally, multiple regression analysis after adjusting for various covariates showed that blood cadmium was significantly higher in the low-ferritin group in women, men, and all participants compared with the normal group. We also found an association between serum ferritin and blood cadmium among never-smoking participants. Discussion: We found, similar to other recent population-based studies, an association between iron deficiency and increased blood cadmium in men and women, independent of smoking status. The results of the present study show that iron deficiency is associated with increased levels of blood cadmium in the general population.« less
Differential white cell count by centrifugal microfluidics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sommer, Gregory Jon; Tentori, Augusto M.; Schaff, Ulrich Y.
We present a method for counting white blood cells that is uniquely compatible with centrifugation based microfluidics. Blood is deposited on top of one or more layers of density media within a microfluidic disk. Spinning the disk causes the cell populations within whole blood to settle through the media, reaching an equilibrium based on the density of each cell type. Separation and fluorescence measurement of cell types stained with a DNA dye is demonstrated using this technique. The integrated signal from bands of fluorescent microspheres is shown to be proportional to their initial concentration in suspension. Among the current generationmore » of medical diagnostics are devices based on the principle of centrifuging a CD sized disk functionalized with microfluidics. These portable 'lab on a disk' devices are capable of conducting multiple assays directly from a blood sample, embodied by platforms developed by Gyros, Samsung, and Abaxis. [1,2] However, no centrifugal platform to date includes a differential white blood cell count, which is an important metric complimentary to diagnostic assays. Measuring the differential white blood cell count (the relative fraction of granulocytes, lymphocytes, and monocytes) is a standard medical diagnostic technique useful for identifying sepsis, leukemia, AIDS, radiation exposure, and a host of other conditions that affect the immune system. Several methods exist for measuring the relative white blood cell count including flow cytometry, electrical impedance, and visual identification from a stained drop of blood under a microscope. However, none of these methods is easily incorporated into a centrifugal microfluidic diagnostic platform.« less
Krüger, Jan-Christopher; Meves, Saskia H; Kara, Kaffer; Mügge, Andreas; Neubauer, Horst
2014-10-01
Several platelet function test systems exist for the evaluation of the platelet inhibitory effect in patients on P2Y12 inhibitors and/or acetylsalicylic acid (ASA, aspirin) therapy. Studies comparing different available assays found only a poor correlation. The objective of the present study was to evaluate the correlation and agreement between single electrode (SEA) and multiple electrode (MEA) aggregometry. In whole blood arachidonic acid (AA) and adenosine diphosphate (ADP)-induced platelet aggregation was measured simultaneously using SEA (Chrono-Log) and MEA (Multiplate). We analyzed a total of 226 measurements taken from 58 patients on single ASA therapy or dual antiplatelet therapy with ASA and a thienopyridine. A cut-off value for clopidogrel/prasugrel high on-treatment platelet reactivity (HPR) of > 47 units (U) was chosen for MEA testing using hirudin and > 5 Ohm for SEA with citrate anticoagulated blood samples. The respective cut-off values for ASA HPR were > 30 U for the MEA assay and > 1 Ohm for SEA testing. There was a good correlation of the prevalence of thienopyridine-HPR in both whole blood assays (Spearman rank correlation coefficient r = 0.698) and a good inter-rate accordance (Cohen's Kappa statistic κ = 0.648). For AA-induced aggregation, the correlation of the results obtained was significant (r = 0.536; p < 0.001) and detecting ASA-HPR revealed a moderate (κ = 0.482) correlation between both impedance aggregometry assays. Platelet function testing using SEA and MEA provided both good accordance and correlation and therefore study results obtained by these two assays similarly enabled the detection of HPR of thienopyridine (and ASA) therapy.
Neonatal Risk Factors for Treatment-Demanding Retinopathy of Prematurity: A Danish National Study.
Slidsborg, Carina; Jensen, Aksel; Forman, Julie Lyng; Rasmussen, Steen; Bangsgaard, Regitze; Fledelius, Hans Callø; Greisen, Gorm; la Cour, Morten
2016-04-01
One goal of the study was to identify "new" statistically independent risk factors for treatment-demanding retinopathy of prematurity (ROP). Another goal was to evaluate whether any new risk factors could explain the increase in the incidence of treatment-demanding ROP over time in Denmark. A retrospective, register-based cohort study. The study included premature infants (n = 6490) born in Denmark from 1997 to 2008. The study sample and the 31 candidate risk factors were identified in 3 national registers. Data were linked through a unique civil registration number. Each of the 31 candidate risk factors were evaluated in univariate analyses, while adjusted for known risk factors (i.e., gestational age [GA] at delivery, small for gestational age [SGA], multiple births, and male sex). Significant outcomes were analyzed thereafter in a backward selection multiple logistic regression model. Treatment-demanding ROP and its associations to candidate risk factors. Mechanical ventilation (odds ratio [OR], 2.84; 95% confidence interval [CI], 1.99-4.08; P < 0.01) and blood transfusion (OR, 1.97; 95% CI, 1.20-3.14; P = 0.01) were the only new statistically independent risk factors, in addition to GA at delivery, SGA, multiple births, and male sex. Modification in these prognostic factors for ROP did not cause an increase in treatment-demanding ROP. In a large study population, blood transfusion and mechanical ventilation were the only new statistically independent risk factors to predict the development of treatment-demanding ROP. Modification in the neonatal treatment with mechanical ventilation or blood transfusion did not cause the observed increase in the incidence of preterm infants with treatment-demanding ROP during a recent birth period (2003-2008). Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Hemolysis associated with pneumatic tube system transport for blood samples
Kara, Hasan; Bayir, Aysegul; Ak, Ahmet; Degirmenci, Selim; Akinci, Murat; Agacayak, Ahmet; Marcil, Emine; Azap, Melih
2014-01-01
Objective: The frequency of hemolysis of blood samples may be increased by transport in a pneumatic tube system. The purpose of this study was to evaluate the effect of pneumatic tube system transport on hemolysis of blood samples. Methods: Blood samples were transported from the emergency department to the hospital laboratory manually by hospital staff (49 patients) or with a pneumatic tube system (53 patients). The hemolysis index and serum chemistry studies were performed on the blood samples and compared between the different methods of transport. Results: The blood samples that were transported by the pneumatic tube system had a greater frequency of hemolysis and greater mean serum potassium and median creatinine, aspartate aminotransferase, and lactate dehydrogenase levels than samples transported manually. Conclusion: Blood samples transported from the emergency department to the hospital laboratory by a pneumatic tube system may have a greater frequency of hemolysis than samples transported manually. This may necessitate repeat phlebotomy and cause a delay in completing the laboratory analysis. PMID:24639830
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garner, Rochelle E., E-mail: rochelle.garner@canad
Background: Cadmium has been inconsistently related to blood pressure and hypertension. The present study seeks to clarify the relationship between cadmium levels found in blood and urine, blood pressure and hypertension in a large sample of adults. Methods: The study sample included participants ages 20 through 79 from multiple cycles of the Canadian Health Measures Survey (2007 through 2013) with measured blood cadmium (n=10,099) and urinary cadmium (n=6988). Linear regression models examined the association between natural logarithm transformed cadmium levels and blood pressure (separate models for systolic and diastolic blood pressure) after controlling for known covariates. Logistic regression models weremore » used to examine the association between cadmium and hypertension. Models were run separately by sex, smoking status, and body mass index category. Results: Men had higher mean systolic (114.8 vs. 110.8 mmHg, p<0.01) and diastolic (74.0 vs. 69.6 mmHg, p<0.01) blood pressure compared to women. Although, geometric mean blood (0.46 vs. 0.38 µg/L, p<0.01) and creatinine-adjusted standardized urinary cadmium levels (0.48 vs. 0.38 µg/L, p<0.01) were higher among those with hypertension, these differences were no longer significant after adjustment for age, sex and smoking status. In overall regression models, increases in blood cadmium were associated with increased systolic (0.70 mmHg, 95% confidence interval [CI]=0.25–1.16, p<0.01) and diastolic blood pressure (0.74 mmHg, 95% CI=0.30–1.19, p<0.01). The associations between urinary cadmium, blood pressure and hypertension were not significant in overall models. Model stratification revealed significant and negative associations between urinary cadmium and hypertension among current smokers (OR=0.61, 95% CI=0.44–0.85, p<0.01), particularly female current smokers (OR=0.52, 95% CI=0.32–0.85, p=0.01). Conclusion: This study provides evidence of a significant association between cadmium levels, blood pressure and hypertension. However, the significance and direction of this association differs by sex, smoking status, and body mass index category. - Highlights: • Blood and urinary cadmium levels higher among those with hypertension. • Evidence of association between cadmium levels, blood pressure and hypertension. • Significance and direction of association differs by sex, smoking status, and BMI. • Higher urinary cadmium levels lower hypertension risk for current (female) smokers.« less
The influence of platelets, plasma and red blood cells on functional haemostatic assays.
Bochsen, Louise; Johansson, Pär I; Kristensen, Annemarie T; Daugaard, Gedske; Ostrowski, Sisse R
2011-04-01
Functional whole blood haemostatic assays are used increasingly to guide transfusion therapy and monitor medical treatment and are also applied for in-vitro evaluations of the haemostatic potential of stored platelets. We investigated how the cellular and plasmatic elements, both isolated and combined, influenced the two methodologically different assays, thrombelastography (TEG) and impedance aggregometry (Multiplate). Platelet-rich plasma (200 × 10/l) or pure plasma (0 platelets), with and without added red blood cells (RBCs), hematocrit 0, 0.15 or 0.29, were produced in vitro from platelet concentrates, fresh frozen plasma and stored RBC. Pure platelets were investigated by removing plasma components from platelet concentrates by diafiltration against the platelet storage solution Intersol. Plasma was readded by diafiltration against plasma in Intersol. Haemostatic function was evaluated by TEG and Multiplate. In the TEG, increasing amounts of RBC reduced clot strength and clot kinetics (α-angle), most markedly in plasma/RBC without platelets. In contrast, RBC in a platelet concentrate matrix enhanced Multiplate aggregation in response to weak agonists (ADP and arachidonic acid). Furthermore, removing plasma from platelet concentrates eliminated the TEG response and diminished the Multiplate aggregation response, but readding plasma to the pure platelet concentrates restored the response. Each of the elements in whole blood, plasma, platelets and RBC, affected the Multiplate and TEG results differently. The results emphasize that the concentrations of all cellular and plasmatic components in whole blood should be taken into account when interpreting results obtained by TEG and multiplate.
Blood meal analysis of tabanid fly after it biting the rare Sumatran rhinoceros.
Rovie-Ryan, Jeffrine Japning; Zainuddin, Zainal Zahari; Marni, Wahap; Ahmad, Abdul Hamid; Ambu, Laurentius N; Payne, Junaidi
2013-02-01
To demonstrate a noninvasive large mammalian genetic sampling method using blood meal obtained from a tabanid fly. Blood meal was recovered from the abdomen of an engorged tabanid fly (Haematopota sp.) which was captured immediately after biting a Sumatran rhino in captivity. The blood was applied on to a Whatman FTA(®) blood card. Subsequent laboratory work was conducted to extract, amplify and sequence the DNA from the sample. Validation was done by sampling the hair follicles and blood samples from the rhinoceros and subjecting it to the same laboratory process. BLAST search and constructed phylogenetic trees confirmed the blood meal samples were indeed from the rhino. This method could be used in the field application to noninvasively collect genetic samples. Collection of tabanids and other haematophagous arthropods (e.g. mosquitoes and ticks) and other blood-sucking parasites (e.g. leeches and worms) could also provide information on vector-borne diseases.
Taly, Valerie; Pekin, Deniz; Benhaim, Leonor; Kotsopoulos, Steve K; Le Corre, Delphine; Li, Xinyu; Atochin, Ivan; Link, Darren R; Griffiths, Andrew D; Pallier, Karine; Blons, Hélène; Bouché, Olivier; Landi, Bruno; Hutchison, J Brian; Laurent-Puig, Pierre
2013-12-01
Multiplex digital PCR (dPCR) enables noninvasive and sensitive detection of circulating tumor DNA with performance unachievable by current molecular-detection approaches. Furthermore, picodroplet dPCR facilitates simultaneous screening for multiple mutations from the same sample. We investigated the utility of multiplex dPCR to screen for the 7 most common mutations in codons 12 and 13 of the KRAS (Kirsten rat sarcoma viral oncogene homolog) oncogene from plasma samples of patients with metastatic colorectal cancer. Fifty plasma samples were tested from patients for whom the primary tumor biopsy tissue DNA had been characterized by quantitative PCR. Tumor characterization revealed that 19 patient tumors had KRAS mutations. Multiplex dPCR analysis of the plasma DNA prepared from these samples identified 14 samples that matched the mutation identified in the tumor, 1 sample contained a different KRAS mutation, and 4 samples had no detectable mutation. Among the tumor samples that were wild type for KRAS, 2 KRAS mutations were identified in the corresponding plasma samples. Duplex dPCR (i.e., wild-type and single-mutation assay) was also used to analyze plasma samples from patients with KRAS-mutated tumors and 5 samples expected to contain the BRAF (v-raf murine sarcoma viral oncogene homolog B) V600E mutation. The results for the duplex analysis matched those for the multiplex analysis for KRAS-mutated samples and, owing to its higher sensitivity, enabled detection of 2 additional samples with low levels of KRAS-mutated DNA. All 5 samples with BRAF mutations were detected. This work demonstrates the clinical utility of multiplex dPCR to screen for multiple mutations simultaneously with a sensitivity sufficient to detect mutations in circulating DNA obtained by noninvasive blood collection.
Debey-Pascher, Svenja; Hofmann, Andrea; Kreusch, Fatima; Schuler, Gerold; Schuler-Thurner, Beatrice; Schultze, Joachim L.; Staratschek-Jox, Andrea
2011-01-01
Microarray-based transcriptome analysis of peripheral blood as surrogate tissue has become an important approach in clinical implementations. However, application of gene expression profiling in routine clinical settings requires careful consideration of the influence of sample handling and RNA isolation methods on gene expression profile outcome. We evaluated the effect of different sample preservation strategies (eg, cryopreservation of peripheral blood mononuclear cells or freezing of PAXgene-stabilized whole blood samples) on gene expression profiles. Expression profiles obtained from cryopreserved peripheral blood mononuclear cells differed substantially from those of their nonfrozen counterpart samples. Furthermore, expression profiles in cryopreserved peripheral blood mononuclear cell samples were found to undergo significant alterations with increasing storage period, whereas long-term freezing of PAXgene RNA stabilized whole blood samples did not significantly affect stability of gene expression profiles. This report describes important technical aspects contributing toward the establishment of robust and reliable guidance for gene expression studies using peripheral blood and provides a promising strategy for reliable implementation in routine handling for diagnostic purposes. PMID:21704280
[Acinetobacter baumannii: an important pathogen with multidrug resistance in newborns].
Celik, Istemi Han; Demirel, Gamze; Tatar Aksoy, Hatice; Saygan, Sibel; Canpolat, Fuat Emre; Uras, Nurdan; Oğuz, Serife Suna; Erdeve, Omer; Dilmen, Uğur
2011-10-01
Nosocomial sepsis agents with multidrug resistance have led to higher morbidity and mortality in premature infants in the recent years. Acinetobacter baumannii has become a leading cause of nosocomial sepsis in several neonatal intensive care units. In this study, the demographic, clinic, microbiologic characteristics and risk factors of 21 premature infants hospitalized in newborn intensive care unit between January 2010-February 2011 and developed A.baumannii infection, have been evaluated retrospectively. The isolates were identified by conventional methods and antibiotic susceptibility tests were performed by Vitek 2 GN and AST-N090 using Vitek 2 Compact system (BioMerieux, France). A.baumannii was isolated from the blood samples of 10 patients, central venous catheter samples of three patients, CSF samples of two, tracheal aspirate of two and urine sample of one patient. In two patients both blood and central venous catheter samples and in one patient both blood and CSF samples revealed A.baumannii. Gestational age was between 22-30 weeks and birth weight was between 500-1320 grams (17 were < 1000 g) in 19 patients. A.baumannii caused early onset (≤ 3 days) sepsis in four, and late onset (≥ 4 days) sepsis in 17 patients. The main risk factors were detected as mechanical ventilation (n= 20, 95%), prematurity (n= 19, 91%), total parenteral nutrition (n= 17, 81%) and central catheter use (n= 14, 67%). Antibiotics with highest rates of susceptibility were gentamicin (18/21), amikacin (14/21), and colistin (10/21). Twenty (95%) isolates had multiple drug resistance. Amikacin, gentamicin, colistin and imipenem were used for treatment, however 12 infants, 8 of which due to sepsis, died. In conclusion, A.baumannii which is an important nosocomial sepsis agent with multidrug resistance, is increasing in incidence. To control Acinetobacter infections especially in low-birth weight infants, the use of invasive procedures, total parenteral nutrition and broad spectrum antibiotics should be limited and infected patients should be isolated besides establishment of other appropriate infection control measures.
Koppelman, M H G M; van Swieten, P; Cuijpers, H T M
2011-06-01
European regulations require testing of manufacturing plasma for parvovirus B19 (B19) DNA to limit the load of this virus to a maximum acceptable level of 10 IU/µL. To meet this requirement, most manufacturers introduced a test algorithm to identify and eliminate high-load donations before making large manufacturing pools of plasma units. Sanquin screens all donations using a commercial assay from Roche and an in-house assay. Between 2006 and 2009, 6.2 million donations were screened using two different polymerase chain reaction (PCR) assays targeting B19 DNA. Donations with B19 DNA loads of greater than 1 × 10(6) IU/mL showing significant differences in viral load between the two assays were further analyzed by sequencing analysis. A total of 396 donations with B19 DNA loads of greater than 1 × 10(6) IU/mL were identified. Fifteen samples (3.8%) had discordant test results; 10 samples (2.5%) were underquantified by the Roche assay, two samples (0.5%) were underquantified by the in-house assay, and three samples (0.8%) were not detected by the Roche assay. Sequencing analysis revealed mismatches in primer and probe-binding regions. Phylogenetic analysis showed that 12 samples were B19 Genotype 1. The three samples not detected by the Roche assay were B19 Genotype 2. This study shows that 3.8% of the viremic B19 DNA-positive donations are not quantified correctly by the Roche or in-house B19 DNA assays. B19 Genotype 1 isolates showing incorrect test results are more common than B19 Genotype 2 or 3 isolates. Newly designed B19 PCR assays for blood screening should preferably have multiplexed formats targeting multiple regions of the B19 genome. © 2010 American Association of Blood Banks.
Giraudon, I; Cathcart, S; Blomqvist, S; Littleton, A; Surman-Lee, S; Mifsud, A; Anaraki, S; Fraser, G
2009-06-01
To describe the epidemiology of an outbreak of Salmonella enteritidis phage type 1 (PT1) infection associated with a fast food premises, and to identify the causative factors leading to an acute outbreak with high attack rate and severe illness including hospital admission. Integrated descriptive study of epidemiology, food and environmental microbiology, and professional environmental health assessment, supplemented by a case-case analytical study. Cases were identified through multiple sources and were interviewed to identify food items consumed. Descriptive epidemiology of all cases and a case-case analytical study of risk factors for severe illness were undertaken. Microbiological investigation included analysis and typing of pathogens from stools, blood and environmental surfaces. Professional environmental heath assessment of the premises was undertaken. S. enteritidis PT1 was recovered from two-thirds of faecal samples. Three cases had dual infection with enterotoxin-producing Clostridium perfringens. S. enteritidis PT1 was isolated from 14 of 40 food samples examined and C. perfringens was isolated from eight food samples. Environmental health inspection of the premises revealed multiple deficiencies, including deficits in food preparation and hygiene consistent with multiple cross-contamination, and time-temperature abuse of sauces widely used across menu items. Severe cases were associated with consumption of chips and salad. Outbreaks from fast food premises have been infrequently described. This outbreak demonstrates the potential for fast food premises, with multiple deficiencies in food preparation and hygiene, to produce large, intense community outbreaks with high attack rates and severe illness, highly confined in space and time.
Vongsakulyanon, A; Kitpoka, P; Kunakorn, M; Srikhirin, T
2015-12-01
To develop reliable and convenient methods for Miltenberger (Mi(a) ) blood group typing. To apply real-time polymerase chain reaction (qPCR) melting curve analysis to Mi(a) blood group typing. The Mi(a) blood group is the collective set of glycophorin hybrids in the MNS blood group system. Mi(a+) blood is common among East Asians and is also found in the Thai population. Incompatible Mi(a) blood transfusions pose the risk of life-threatening haemolysis; therefore, Mi(a) blood group typing is necessary in ethnicities where the Mi(a) blood group is prevalent. One hundred and forty-three blood samples from Thai blood donors were used in the study. The samples included 50 Mi(a+) samples and 93 Mi(a-) samples, which were defined by serology. The samples were typed by Mi(a) typing qPCR, and 50 Mi(a+) samples were sequenced to identify the Mi(a) subtypes. Mi(a) subtyping qPCR was performed to define GP.Mur. Both Mi(a) typing and Mi(a) subtyping were tested on a conventional PCR platform. The results of Mi(a) typing qPCR were all concordant with serology. Sequencing of the 50 Mi(a+) samples revealed 47 GP.Mur samples and 3 GP.Hop or Bun samples. Mi(a) subtyping qPCR was the supplementary test used to further define GP.Mur from other Mi(a) subtypes. Both Mi(a) typing and Mi(a) subtyping performed well using a conventional PCR platform. Mi(a) typing qPCR correctly identified Mi(a) blood groups in a Thai population with the feasibility of Mi(a) subtype discrimination, and Mi(a) subtyping qPCR was able to further define GP.Mur from other Mi(a) subtypes. © 2015 British Blood Transfusion Society.
Hensler, T; Sauerland, S; Riess, P; Hess, S; Helling, H J; Andermahr, J; Bouillon, B; Neugebauer, E A
2000-10-01
Besides interleukin (IL)-10, accumulating evidence from in vitro studies has indicated a strong antiinflammatory capacity for IL-13. A prospective clinical study was undertaken to assess the influence of additional brain injury on systemic IL-10 and IL-13 levels as markers for the antiinflammatory state in trauma patients. The course of IL-10 and IL-13 plasma levels from 32 patients with an isolated severe head trauma (SHT), 50 patients with multiple injuries and additional SHT and 39 patients with multiple injuries without SHT was detected using ELISA-technique. Blood samples from 37 healthy blood donors were analysed for control. IL-10 levels were significantly elevated in all 3 injury groups within 3 h after trauma. The lowest initial release was detected in patients with an isolated SHT (Injury severity score; ISS: 18.1 +/- 5.6). No difference could be demonstrated for the IL-10 levels from multiple injured patients with (ISS: 35.3 +/- 9.6) or without additional SHT (ISS: 25.5 +/- 11.7), though there were relevant differences in the ISS. In contrast, the IL-13 plasma levels were not elevated systemically after trauma. IL-10 but not IL-13 is a detectable antiinflammatory marker in trauma patients with or without brain injury and to a minor degree in patients with an isolated SHT.
Plasma catecholamines and plasma corticosterone following restraint stress in juvenile alligators.
Lance, V A; Elsey, R M
1999-05-01
Ten juvenile alligators, mean body mass 793 g, hatched from artificially incubated eggs and raised under controlled conditions, were held out of water with their jaws held closed for 48 hr. An initial blood sample was taken and further samples collected at 1, 2, 4, 8, 24, and 48 hr. Epinephrine, norepinephrine, and dopamine were measured in plasma aliquots of 1.5 ml using high pressure liquid chromatography with electrochemical detection. Corticosterone was measured by radioimmunoassay. Plasma glucose was measured using the Trinder method and plasma calcium, cholesterol, and triglycerides were measured in an autoanalyzer. Epinephrine was about 4 ng/ml at the initial bleed, but declined steadily to < 0.4 ng/ml by 24 hr. Norepinephrine was also about 4 ng/ml at the initial bleed, but rose to over 8 ng/ml at 1 hr, and then declined to < 0.2 ng/ml at 24 hr. A second, but smaller increase in plasma norepinephrine was seen at 48 hr. Plasma dopamine was low at the initial bleed (< 0.7 ng/ml), rose to over 8 ng/ml at 1 hr, then declined to < 0.2 ng/ml. Plasma corticosterone rose progressively for the first 4 hr, declined at 8 hr and 24 hr, then rose again at 48 hr. Plasma glucose rose significantly by 24 hr and remained elevated for 48 hr. Plasma calcium increased at 1, 2, and 4 hr then returned to levels not significantly different from the initial sample at 24 and 48 hr. The white blood cells showed changes indicating immune system suppression. By the end of the treatment the hetorophil/lymphocyte ratio increased to 4.7. These results suggest that handling alligators, taking multiple blood samples, and keeping them restrained for more than 8 hr is a severe stress to the animals.
Familial cancer associated with a polymorphism in ARLTS1.
Calin, George Adrian; Trapasso, Francesco; Shimizu, Masayoshi; Dumitru, Calin Dan; Yendamuri, Sai; Godwin, Andrew K; Ferracin, Manuela; Bernardi, Guido; Chatterjee, Devjani; Baldassarre, Gustavo; Rattan, Shashi; Alder, Hansjuerg; Mabuchi, Hideaki; Shiraishi, Takeshi; Hansen, Lise Lotte; Overgaard, Jens; Herlea, Vlad; Mauro, Francesca Romana; Dighiero, Guillaume; Movsas, Benjamin; Rassenti, Laura; Kipps, Thomas; Baffa, Raffaele; Fusco, Alfredo; Mori, Masaki; Russo, Giandomenico; Liu, Chang-Gong; Neuberg, Donna; Bullrich, Florencia; Negrini, Massimo; Croce, Carlo M
2005-04-21
The finding of hemizygous or homozygous deletions at band 14 on chromosome 13 in a variety of neoplasms suggests the presence of a tumor-suppressor locus telomeric to the RB1 gene. We studied samples from 216 patients with various types of sporadic tumors or idiopathic pancytopenia, peripheral-blood samples from 109 patients with familial cancer or multiple cancers, and control blood samples from 475 healthy people or patients with diseases other than cancer. We performed functional studies of cell lines lacking ARLTS1 expression with the use of both the full-length ARLTS1 gene and a truncated variant. We found a gene at 13q14, ARLTS1, a member of the ADP-ribosylation factor family, with properties of a tumor-suppressor gene. We analyzed 800 DNA samples from tumors and blood cells from patients with sporadic or familial cancer and controls and found that the frequency of a nonsense polymorphism, G446A (Trp149Stop), was similar in controls and patients with sporadic tumors but was significantly more common among patients with familial cancer than among those in the other two groups (P=0.02; odds ratio, 5.7; 95 percent confidence interval, 1.3 to 24.8). ARLTS1 was down-regulated by promoter methylation in 25 percent of the primary tumors we analyzed. Transfection of wild-type ARLTS1 into A549 lung-cancer cells suppressed tumor formation in immunodeficient mice and induced apoptosis, whereas transfection of truncated ARLTS1 had a limited effect on apoptosis and tumor suppression. Microarray analysis revealed that the wild-type and Trp149Stop-transfected clones had different expression profiles. A genetic variant of ARLTS1 predisposes patients to familial cancer. Copyright 2005 Massachusetts Medical Society.
Piersma, Tjeerd W.; Bekkers, René; Klinkenberg, Elisabeth F.; de Kort, Wim L.A.M.; Merz, Eva-Maria
2017-01-01
Background The ageing population and recent migration flows may negatively affect the blood supply in the long term, increasing the importance of targeted recruitment and retention strategies to address donors. This review sought to identify individual, network and contextual characteristics related to blood donor status and behaviour, to systematically discuss differences between study results, and to identify possible factors to target in recruitment and retention efforts. Methods The systematic review was conducted in accordance with a predefined PROSPERO protocol (CRD42016039591). After quality assessments by multiple independent raters, a final set of 66 peer-reviewed papers, published between October 2009 and January 2017, were included for review. Results Individual and contextual characteristics of blood donor status and behaviour were categorised into five main lines of research: donor demographics, motivations and barriers, adverse reactions and deferral, contextual factors, and blood centre factors. Results on donor demographics, motivations and barriers, and contextual factors were inconclusive, differing between studies, countries, and sample characteristics. Adverse reactions and deferral were negatively related to blood donor behaviour. Blood centre factors play an important role in donor management, e.g., providing information, reminders, and (non-)monetary rewards. No studies were found on network characteristics of (non-)donors. Discussion Although individual and contextual characteristics strongly relate to blood donor status and behaviour, mechanisms underlying these relations have not been studied sufficiently. We want to stress the importance of longitudinal studies in donor behaviour, exploring the role of life events and network characteristics within blood donor careers. Increased understanding of donor behaviour will assist policy makers of blood collection agencies, with the ultimate goal of safeguarding a sufficient and matching blood supply. PMID:28686151
McLawhorn, Alexander S; Levack, Ashley E; Fields, Kara G; Sheha, Evan D; DelPizzo, Kathryn R; Sink, Ernest L
2016-03-01
Periacetabular osteotomy (PAO) reorients the acetabular cartilage through a complex series of pelvic osteotomies, which risks significant blood loss often necessitating blood transfusion. Therefore, it is important to identify effective strategies to manage blood loss and decrease morbidity after PAO. The purpose of this study was to determine the association of epsilon-aminocaproic acid (EACA), an antifibrinolytic agent, with blood loss from PAO. Ninety-three patients out of 110 consecutive patients that underwent unilateral PAO for acetabular dysplasia met inclusion criteria. Fifty patients received EACA intraoperatively. Demographics, autologous blood predonation, anesthetic type, intraoperative estimated blood loss (EBL), cell-saver utilization, and transfusions were recorded. Total blood loss was calculated. Two-sample t-test and chi-square or Fisher's exact test were used as appropriate. The associations between EACA administration and calculated EBL, cell-saver utilization, intraoperative EBL, and maximum difference in postoperative hemoglobin were assessed via multiple regression, adjusting for confounders. Post hoc power analysis demonstrated sufficient power to detect a 250-mL difference in calculated EBL between groups. Alpha level was 0.05 for all tests. No demographic differences existed between groups. Mean blood loss and allogeneic transfusion rates were not statistically significant between groups (P = .093 and .170, respectively). There were no differences in cell-saver utilization, intraoperative EBL, and/or postoperative hemoglobin. There was a higher rate of autologous blood utilization in the group not receiving EACA because of a clinical practice change. EACA administration was not associated with a statistically significant reduction in blood loss or allogeneic transfusion in patients undergoing PAO. Copyright © 2016 Elsevier Inc. All rights reserved.
Piersma, Tjeerd W; Bekkers, René; Klinkenberg, Elisabeth F; De Kort, Wim L A M; Merz, Eva-Maria
2017-09-01
The ageing population and recent migration flows may negatively affect the blood supply in the long term, increasing the importance of targeted recruitment and retention strategies to address donors. This review sought to identify individual, network and contextual characteristics related to blood donor status and behaviour, to systematically discuss differences between study results, and to identify possible factors to target in recruitment and retention efforts. The systematic review was conducted in accordance with a predefined PROSPERO protocol (CRD42016039591). After quality assessments by multiple independent raters, a final set of 66 peer-reviewed papers, published between October 2009 and January 2017, were included for review. Individual and contextual characteristics of blood donor status and behaviour were categorised into five main lines of research: donor demographics, motivations and barriers, adverse reactions and deferral, contextual factors, and blood centre factors. Results on donor demographics, motivations and barriers, and contextual factors were inconclusive, differing between studies, countries, and sample characteristics. Adverse reactions and deferral were negatively related to blood donor behaviour. Blood centre factors play an important role in donor management, e.g., providing information, reminders, and (non-)monetary rewards. No studies were found on network characteristics of (non-)donors. Although individual and contextual characteristics strongly relate to blood donor status and behaviour, mechanisms underlying these relations have not been studied sufficiently. We want to stress the importance of longitudinal studies in donor behaviour, exploring the role of life events and network characteristics within blood donor careers. Increased understanding of donor behaviour will assist policy makers of blood collection agencies, with the ultimate goal of safeguarding a sufficient and matching blood supply.
Isohashi, Kayako; Shimosegawa, Eku; Naka, Sadahiro; Kanai, Yasukazu; Horitsugi, Genki; Mochida, Ikuko; Matsunaga, Keiko; Watabe, Tadashi; Kato, Hiroki; Tatsumi, Mitsuaki; Hatazawa, Jun
2016-12-01
In boron neutron capture therapy (BNCT), positron emission tomography (PET) with 4-borono-2- 18 F-fluoro-phenylalanine (FBPA) is the only method to estimate an accumulation of 10 B to target tumor and surrounding normal tissue after administering 10 B carrier of L-paraboronophenylalanine and to search the indication of BNCT for individual patient. Absolute concentration of 10 B in tumor has been estimated by multiplying 10 B concentration in blood during BNCT by tumor to blood radioactivity (T/B) ratio derived from FBPA PET. However, the method to measure blood radioactivity either by blood sampling or image data has not been standardized. We compared image-derived blood radioactivity of FBPA with blood sampling data and studied appropriate timing and location for measuring image-derived blood counts. We obtained 7 repeated whole-body PET scans in five healthy subjects. Arterialized venous blood samples were obtained from the antecubital vein, heated in a heating blanket. Time-activity curves (TACs) of image-derived blood radioactivity were obtained using volumes of interest (VOIs) over ascending aorta, aortic arch, pulmonary artery, left and right ventricles, inferior vena cava, and abdominal aorta. Image-derived blood radioactivity was compared with those measured by blood sampling data in each location. Both the TACs of blood sampling radioactivity in each subject, and the TACs of image-derived blood radioactivity showed a peak within 5 min after the tracer injection, and promptly decreased soon thereafter. Linear relationship was found between blood sampling radioactivity and image-derived blood radioactivity in all the VOIs at any timing of data sampling (p < 0.001). Image-derived radioactivity measured in the left and right ventricles 30 min after injection showed high correlation with blood radioactivity. Image-derived blood radioactivity was lower than blood sampling radioactivity data by 20 %. Reduction of blood radioactivity of FBPA in left ventricle after 30 min of FBPA injection was minimal. We conclude that the image-derived T/B ratio can be reliably used by setting the VOI on the left ventricle at 30 min after FBPA administration and correcting for underestimation due to partial volume effect and reduction of FBPA blood radioactivity.
Relationship of vitamin D levels to blood pressure in a biethnic population.
Sakamoto, R; Jaceldo-Siegl, K; Haddad, E; Oda, K; Fraser, G E; Tonstad, S
2013-08-01
Accumulating epidemiological and clinical studies have suggested that vitamin D insufficiency may be associated with hypertension. Blacks tend to have lower vitamin D levels than Whites, but it is unclear whether this difference explains the higher blood pressure (BP) observed in Blacks in a population with healthy lifestyle practices. We examined cross-sectional data in the Adventist Health Study-2 (AHS-2), a cohort of non-smoking, mostly non-drinking men and women following a range of diets from vegan to non-vegetarian. Each participant provided dietary, demographic, lifestyle and medical history data. Measurements of weight, height, waist circumference, percent body fat and blood pressure and fasting blood samples were obtained from a randomly selected non-diabetic sample of 284 Blacks and 284 Whites aged 30-95 years. Multiple regression analyses were used to assess independent relationships between blood pressure and 25(OH)D levels. Levels of 25(OH)D were inversely associated with systolic BP in Whites after control for age, gender, BMI, and use of BP-lowering medications (β-coefficient -0.23 [95% CI, -0.43, -0.03; p = 0.02]). This relationship was not seen in Blacks (β-coefficient 0.08 [95% CI, -0.14, 0.30; p = 0.4]). Results were similar when controlling for waist circumference or percentage body fat instead of BMI. No relationship between serum 25(OH)D and diastolic BP was seen. Systolic BP is inversely associated with 25(OH)D levels in Whites but not in Blacks. Vitamin D may not be a major contributor to the White-Black differential in BP. Copyright © 2012 Elsevier B.V. All rights reserved.
The effect of ketoconazole on whole blood and skin ciclosporin concentrations in dogs.
Gray, Laura L; Hillier, Andrew; Cole, Lynette K; Rajala-Schultz, Päivi J
2013-02-01
Ciclosporin (CSA) is approved for the treatment of canine atopic dermatitis. Ciclosporin is metabolized by liver cytochrome P450 enzymes, a process inhibited by ketoconazole (KTZ). The aims of this study were to determine skin and blood CSA concentrations when CSA was administered alone at 5.0 (Treatment 1) or 2.5 mg/kg (Treatment 2) and when CSA was administered at 2.5 mg/kg concurrently with KTZ at 5 (Treatment 3) or 2.5 mg/kg (Treatment 4). We hypothesized that skin and blood CSA concentrations in Treatment 1 would not differ from those obtained with T3 or T4. In a randomized cross-over study, six healthy research dogs received each of the treatments (Treatment 1, 2, 3 and 4) once daily for 7 days. After the first, fourth and seventh dose for each treatment, a peak and trough skin punch biopsy sample and whole blood sample were collected and analysed with high-performance liquid chromatography-tandem mass spectrometry. Data were analysed using a repeated measures approach with PROC MIXED in SAS. Pairwise comparisons were performed with least squares means and Tukey-Kramer adjustment for multiple comparisons. Mean blood CSA concentrations in Treatment 1 were not different from those in Treatment 2 or 4, but were less than in Treatment 3. Mean skin CSA concentrations in Treatment 1 were greater than in Treatment 2, not different from those in Treatment 4, and less than those in Treatment 3. Administration of CSA and KTZ concurrently at 2.5 mg/kg each may be as effective as CSA alone at 5.0 mg/kg for treatment of canine atopic dermatitis. © 2013 The Authors. Veterinary Dermatology © 2013 ESVD and ACVD.
CGG allele size somatic mosaicism and methylation in FMR1 premutation alleles
Pretto, Dalyir I.; Mendoza-Morales, Guadalupe; Lo, Joyce; Cao, Ru; Hadd, Andrew; Latham, Gary J.; Durbin-Johnson, Blythe; Hagerman, Randi; Tassone, Flora
2014-01-01
Background Greater than 200 CGG repeats in the 5′UTR of the FMR1 gene leads to epigenetic silencing and lack of the FMR1 protein, causing Fragile X Syndrome. Individuals carriers of a premutation (PM) allele with 55–200 CGG repeats are typically unmethylated and can present with clinical features defined as FMR1 associated conditions. Methods Blood samples from 17 male PM carriers were assessed clinically and molecularly by Southern Blot, Western Blot, PCR and QRT-PCR. Blood and brain tissue from additional 18 PM males were also similarly examined. Continuous outcomes were modeled using linear regression and binary outcomes were modeled using logistic regression. Results Methylated alleles were detected in different fractions of blood cells in all PM cases (n= 17). CGG repeat numbers correlated with percent of methylation and mRNA levels and, especially in the upper PM range, with greater number of clinical involvements. Inter/intra- tissue somatic instability and differences in percent methylation were observed between blood and fibroblasts (n=4) and also observed between blood and different brain regions in three of the 18 premutation cases examined. CGG repeat lengths in lymphocytes remained unchanged over a period of time ranging from 2–6 years, three cases for whom multiple samples were available. Conclusion In addition to CGG size instability, individuals with a PM expanded alleles can exhibit methylation and display more clinical features likely due to RNA toxicity and/or FMR1 silencing. The observed association between CGG repeat length and percent of methylation with the severity of the clinical phenotypes underscores the potential value of methylation in affected PM to further understand penetrance, inform diagnosis and to expand treatment options. PMID:24591415
Sancilio, Amelia; Eggerman, Mark; Panter-Brick, Catherine
2017-01-01
Biocultural research remains a challenge in the field of global mental health. We sought to test associations between blood pressure and idioms of distress in a population survey. We drew on a randomly selected sample of 991 adults (498 men, 493 women) in Afghanistan, for whom physiological and psychosocial data were systematically collected. Assessment of mental health (Self-Reported Questionnaire, Afghan Symptom Checklist) included conceptualizations of distress related to pressure (fishar), anxiety, and dysphoria, as well as dimensions of negative affect and aggression. We used principal component analysis to map survey responses to fishar, and multiple regressions to examine associations with systolic/diastolic blood pressure, controlling for age, body mass index, and wealth, and differentiating by gender, mental health, and medication. The Afghan sample averaged 129/80 mmHg, with 27.14% of hypertensive individuals. SBP showed inverse associations with reports of low fishar (β = -4.58, P < .001) and high fishar (β = 6.90, P < .001), as did DPB with low fishar (β = -1.55, P < .001) and high fishar (β = 3.77, P < .001). Low and high fishar responses accounted for substantial proportions of SBP data variation (R 2 = 20% and R 2 = 24%), especially in adults on blood pressure medication (R 2 = 58% and R 2 = 49%). Subjective reports of fishar map onto physiological blood pressure more robustly than other conceptualizations of mental distress related to anxiety, dysphoria, negative affect, or aggression. Our results point to the utility of mapping biological and cultural measures of stress and distress, advancing biopsychosocial understandings of wellbeing in global mental health surveys. © 2016 Wiley Periodicals, Inc.
Blood Thinners - Multiple Languages
... List of All Topics All Blood Thinners - Multiple Languages To use the sharing features on this page, please enable JavaScript. Arabic (العربية) ... Bethesda, MD 20894 U.S. Department of Health and Human Services National Institutes of Health Page last updated on 7 February 2018
Hussain, I; Brady, C; Swinn, M; Mathias, C; Fowler, C
2001-01-01
OBJECTIVES—To assess the efficacy and safety of sildenafil citrate (Viagra) in men with erectile dysfunction and parkinsonism due either to Parkinson's disease or multiple system atrophy. METHODS—Twenty four patients with erectile disease were recruited, 12 with Parkinson's disease and 12 with multiple system atrophy, into a randomised, double blind, placebo controlled, crossover study of sildenafil citrate. The starting dose was 50 mg active or placebo medication with the opportunity for dose adjustment depending on efficacy and tolerability. The international index of erectile function questionnaire (IIEF) was used to assess treatment efficacy and a quality of life questionnaire to assess the effect of treatment on sex life and whole life. Criteria for entry included a definite neurological diagnosis and a standing systolic blood pressure of 90-180 mm Hg and diastolic blood pressure of 50-110 mm Hg, on treatment if necessary. Blood pressure was taken at randomisation (visit 2) and crossover (visit 5) lying, sitting, and standing, before and 1 hour after taking the study medication in hospital. RESULTS—Sidenafil citrate was efficacious in men with parkinsonism with a significant improvement, as demonstrated in questionnaire responses, in ability to achieve and maintain an erection and improvement in quality of sex life. In Parkinson's disease there was minimal change in blood pressure between active and placebo medication. In multiple system atrophy, six patients were studied before recruitment was stopped because three men showed a severe drop in blood pressure 1 hour after taking the active medication. Two were already known to have orthostatic hypotension and were receiving treatment with ephedrine and midodrine but the third had asymptomatic hypotension. However, the blood pressures in all three had been within the inclusion criterion for the study protocol. Despite a significant postural fall in blood pressure after sildenafil, all patients with multiple system atrophy reported a good erectile response and were reluctant to discontinue the medication. CONCLUSIONS—Sidenafil citrate (50 mg) is efficacious in the treatment of erectile dysfunction in parkinsonism due to Parkinson's disease or multiple system atrophy; however, it may unmask or exacerbate hypotension in multiple system atrophy. As Parkinson's disease may be diagnostically difficult to distinguish from multiple system atrophy, especially in the early stages, we recommend measurement of lying and standing blood pressure before prescribing sildenafil to men with parkinsonism. Furthermore, such patients should be made aware of seeking medical advice if they develop symptoms on treatment suggestive of orthostatic hypotension. PMID:11511713
Agah, Elmira; Zardoui, Arshia; Saghazadeh, Amene; Ahmadi, Mona; Tafakhori, Abbas; Rezaei, Nima
2018-01-01
Identifying a reliable biomarker may accelerate diagnosis of multiple sclerosis (MS) and lead to early management of the disease. Accumulating evidence suggest that cerebrospinal fluid (CSF) and peripheral blood concentration of osteopontin (OPN) may have diagnostic and prognostic value in MS. We conducted a systematic review and meta-analysis of studies that measured peripheral blood and CSF levels of OPN in MS patients and controls to evaluate the diagnostic potential of this biomarker better. We searched PubMed, Web of Science and Scopus databases to find articles that measured OPN concentration in peripheral blood and CSF samples from MS patients up to October 19, 2016. Q statistic tests and the I2 index were applied for heterogeneity assessment. If the I2 index was less than 40%, the fixed-effects model was used for meta-analysis. Random-effects meta-analysis was chosen if the I2 value was greater than 40%. After removal of duplicates, 918 articles were identified, and 27 of them fulfilled the inclusion criteria. We included 22 eligible studies in the final meta-analysis. MS patients, in general, had considerably higher levels of OPN in their CSF and blood when compared to all types of controls (p<0.05). When the comparisons were made between different subtypes of MS patients and controls, the results pointed to significantly higher levels of OPN in CSF of MS subgroups (p<0.05). All subtypes of MS patients, except CIS patients, had increased blood levels of OPN compared to controls (p<0.05). In the second set of meta-analyses, we compared the peripheral blood and CSF concentrations of OPN between MS patient subtypes. CIS patients had significantly lower levels of OPN both in their peripheral blood and CSF compared to patients with progressive subtypes of MS (p<0.05). CSF concentration of OPN was significantly higher among RRMS patients compared to the CIS patients and SPMS patients (P<0.05). Finally, patients with active MS had significantly higher OPN levels in their CSF compared to patients with stable disease (P = 0.007). The result of this study confirms that increased levels of OPN exist in CSF and peripheral blood of MS patients and strengthens the evidence regarding the clinical utility of OPN as a promising and validated biomarker for MS.
Human toxocariasis: a seroepidemiological survey in the municipality of Campinas (SP), Brazil.
Anaruma Filho, Francisco; Chieffi, Pedro Paulo; Correa, Carlos Roberto Silveira; Camargo, Eide Dias; Silveira, Edilene P Real da; Aranha, Joana José Brandão; Ribeiro, Manoel Carlos S Almeida
2002-01-01
The occurrence of human Toxocara infection was evaluated in three neighborhoods of the periphery of the Campinas municipality (Jardim Santa Mônica, Jardim São Marcos and Jardim Campineiro) in 1999. Forty residences and 138 residents were randomly selected by drawing lots and were submitted to a seroepidemiological survey, which included blood collection for the immunoenzymatic detection (ELISA) of anti-Toxocara antibodies and a blood count, and the application of a semi-structured questionnaire for the evaluation of epidemiological data. Significant levels of anti-Toxocara antibodies were detected in 23.9% of the 1999 samples. No significant difference in the frequency of infection according to age was observed. Environmental contamination with Toxocara eggs was observed in 12.3 and 14.0% of 57 soil samples collected in the same region in December 1998 and July 1999, respectively. Univariate analysis and multiple logistic regression of the data obtained from the questionnaires and of the results of the serological tests, suggest a significant influence of socioeconomic variables on the frequency of human infection with Toxocara under the conditions prevalent in the study area.
Methods to measure target site penetration of antibiotics in critically ill patients.
Schwameis, Richard; Zeitlinger, Markus
2013-02-01
While several tools are necessary to repair a car, the engineer knows exactly which instrument he has to utilize at different parts of the broken machine. Likewise, depending on the information we are interested in, we have to choose different tools to investigate and consecutively understand the multiple aspects that are involved in pharmacokinetics of antimicrobial agents in critically ill patients. Some techniques, like blood sampling, microdialysis or positrons emission tomography (PET) will allow for obtaining continues concentration time profiles while others like bronchoalveolar lavage (BAL), biopsy or surgical tissue samples can only be used a limited number of times per subject. PET and methods based on tissue homogenization will deliver an average of the actual concentrations in intra - and extracellular compartments while investigations in isolated blood cells or microdialysis allow for more distinguished allocation of a concentration to a defined compartment. The present review aims at discussing the advantages and disadvantages of the various methods used for assessing pharmacokinetics in critically ill patients with regard to specific aspects of pharmacokinetic research and further reviews data of selected antibiotics as examples for applications of the individual techniques.
Sharifiyazdi, Hassan; Nazifi, Saeed; Shirzad Aski, Hesamaddin; Shayegh, Hossein
2014-09-01
Hemoplasmas are the trivial name for a group of erythrocyte-parasitizing bacteria of the genus Mycoplasma. This study is the first report of hemoplasma infection in Small Indian Mongoose (Herpestes Javanicus) based on molecular analysis of 16S rDNA. Whole blood samples were collected by sterile methods, from 14 live captured mongooses, in the south of Iran. Candidatus Mycoplasma turicensis (CMt)-like hemoplasma was detected in blood samples from one animal tested. BLAST search and phylogenetic analysis of partial 16S rDNA sequence (933bp) of the hemoplasma from Small Indian mongoose (KJ530704) revealed only 96-97% identity to the previously described CMt followed by 95% and 91% similarity with Mycoplasma coccoides and Mycoplasma haemomuris, respectively. Accordingly, the Iranian mongoose CMt isolate showed a high intra-specific genetic variation compared to all previously reported CMt strains in GenBank. Further molecular studies using multiple phylogenetic markers are required to characterize the exact species of Mongoose-derived hemoplasma. Copyright © 2014 Elsevier Ltd. All rights reserved.
Cutting-edge analysis of extracellular microparticles using ImageStream(X) imaging flow cytometry.
Headland, Sarah E; Jones, Hefin R; D'Sa, Adelina S V; Perretti, Mauro; Norling, Lucy V
2014-06-10
Interest in extracellular vesicle biology has exploded in the past decade, since these microstructures seem endowed with multiple roles, from blood coagulation to inter-cellular communication in pathophysiology. In order for microparticle research to evolve as a preclinical and clinical tool, accurate quantification of microparticle levels is a fundamental requirement, but their size and the complexity of sample fluids present major technical challenges. Flow cytometry is commonly used, but suffers from low sensitivity and accuracy. Use of Amnis ImageStream(X) Mk II imaging flow cytometer afforded accurate analysis of calibration beads ranging from 1 μm to 20 nm; and microparticles, which could be observed and quantified in whole blood, platelet-rich and platelet-free plasma and in leukocyte supernatants. Another advantage was the minimal sample preparation and volume required. Use of this high throughput analyzer allowed simultaneous phenotypic definition of the parent cells and offspring microparticles along with real time microparticle generation kinetics. With the current paucity of reliable techniques for the analysis of microparticles, we propose that the ImageStream(X) could be used effectively to advance this scientific field.
Sturza, Julie; Silver, Monica K; Xu, Lin; Li, Mingyan; Mai, Xiaoqin; Xia, Yankai; Shao, Jie; Lozoff, Betsy; Meeker, John
2016-01-01
Pesticides are associated with poorer neurodevelopmental outcomes, but little is known about the effects on sensory functioning. Auditory brainstem response (ABR) and pesticide data were available for 27 healthy, full-term 9-month-old infants participating in a larger study of early iron deficiency and neurodevelopment. Cord blood was analyzed by gas chromatography-mass spectrometry for levels of 20 common pesticides. The ABR forward-masking condition consisted of a click stimulus (masker) delivered via ear canal transducers followed by an identical stimulus delayed by 8, 16, or 64 milliseconds (ms). ABR peak latencies were evaluated as a function of masker-stimulus time interval. Shorter wave latencies reflect faster neural conduction, more mature auditory pathways, and greater degree of myelination. Linear regression models were used to evaluate associations between total number of pesticides detected and ABR outcomes. We considered an additive or synergistic effect of poor iron status by stratifying our analysis by newborn ferritin (based on median split). Infants in the sample were highly exposed to pesticides; a mean of 4.1 pesticides were detected (range 0-9). ABR Wave V latency and central conduction time (CCT) were associated with the number of pesticides detected in cord blood for the 64ms and non-masker conditions. A similar pattern seen for CCT from the 8ms and 16ms conditions, although statistical significance was not reached. Increased pesticide exposure was associated with longer latency. The relation between number of pesticides detected in cord blood and CCT depended on the infant's cord blood ferritin level. Specifically, the relation was present in the lower cord blood ferritin group but not the higher cord blood ferritin group. ABR processing was slower in infants with greater prenatal pesticide exposure, indicating impaired neuromaturation. Infants with lower cord blood ferritin appeared to be more sensitive to the effects of prenatal pesticide exposure on ABR latency delay, suggesting an additive or multiplicative effect. Copyright © 2016 Elsevier Ltd. All rights reserved.
Sturza, Julie; Silver, Monica K.; Xu, Lin; Li, Mingyan; Mai, Xiaoqin; Xia, Yankai; Shao, Jie; Lozoff, Betsy; Meeker, John
2016-01-01
Background Pesticides are associated with poorer neurodevelopmental outcomes, but little is known about the effects on sensory functioning. Methods Auditory brainstem response (ABR) and pesticide data were available for 27 healthy, full-term 9-month-old infants participating in a larger study of early iron deficiency and neurodevelopment. Cord blood was analyzed by gas chromatography-mass spectrometry for levels of 20 common pesticides. The ABR forward-masking condition consisted of a click stimulus (masker) delivered via ear canal transducers followed by an identical stimulus delayed by 8, 16, or 64 milliseconds (ms). ABR peak latencies were evaluated as a function of masker-stimulus time interval. Shorter wave latencies reflect faster neural conduction, more mature auditory pathways, and greater degree of myelination. Linear regression models were used to evaluate associations between total number of pesticides detected and ABR outcomes. We considered an additive or synergistic effect of poor iron status by stratifying our analysis by newborn ferritin (based on median split). Results Infants in the sample were highly exposed to pesticides; a mean of 4.1 pesticides were detected (range 0-9). ABR Wave V latency and central conduction time (CCT) were associated with the number of pesticides detected in cord blood for the 64ms and non-masker conditions. A similar pattern seen for CCT from the 8ms and 16ms conditions, although statistical significance was not reached. Increased pesticide exposure was associated with longer latency. The relation between number of pesticides detected in cord blood and CCT depended on the infant’s cord blood ferritin level. Specifically, the relation was present in the lower cord blood ferritin group but not the higher cord blood ferritin group. Conclusions ABR processing was slower in infants with greater prenatal pesticide exposure, indicating impaired neuromaturation. Infants with lower cord blood ferritin appeared to be more sensitive to the effects of prenatal pesticide exposure on ABR latency delay, suggesting an additive or multiplicative effect. PMID:27166702
Longitudinal peripheral blood transcriptional analysis of a patient with severe Ebola virus disease
Kash, John C.; Walters, Kathie-Anne; Kindrachuk, Jason; Baxter, David; Scherler, Kelsey; Janosko, Krisztina B.; Adams, Rick D.; Herbert, Andrew S.; James, Rebekah M.; Stonier, Spencer W.; Memoli, Matthew J.; Dye, John M.; Davey, Richard T.; Chertow, Daniel S.; Taubenberger, Jeffery K.
2017-01-01
The 2013–2015 outbreak of Ebola virus disease in Guinea, Liberia, and Sierra Leone was unprecedented in the number of documented cases, but there have been few published reports on immune responses in clinical cases and their relationships with the course of illness and severity of Ebola virus disease. Symptoms of Ebola virus disease can include severe headache, myalgia, asthenia, fever, fatigue, diarrhea, vomiting, abdominal pain, and hemorrhage. Although experimental treatments are in development, there are no current U.S. Food and Drug Administration–approved vaccines or therapies. We report a detailed study of host gene expression as measured by microarray in daily peripheral blood samples collected from a patient with severe Ebola virus disease. This individual was provided with supportive care without experimental therapies at the National Institutes of Health Clinical Center from before onset of critical illness to recovery. Pearson analysis of daily gene expression signatures revealed marked gene expression changes in peripheral blood leukocytes that correlated with changes in serum and peripheral blood leukocytes, viral load, antibody responses, coagulopathy, multiple organ dysfunction, and then recovery. This study revealed marked shifts in immune and antiviral responses that preceded changes in medical condition, indicating that clearance of replicating Ebola virus from peripheral blood leukocytes is likely important for systemic viral clearance. PMID:28404864
Zeng, Zhijun; Huo, Xia; Zhang, Yu; Xiao, Zhehong; Zhang, Yuling; Xu, Xijin
2018-05-12
Environmental lead exposure leads to various deleterious effects on multiple organs and systems, including the hematopoietic system. To explore the effects of lead exposure on platelet indices in preschool children from an informal, lead-contaminated electronic waste (e-waste) recycling area, we collected venous blood samples from 466 preschool children (331 from an e-waste area (Guiyu) and 135 from a non-e-waste area (Haojiang)). Child blood lead levels (BLLs) were determined by graphite furnace atomic absorption spectrophotometry, while platelet indices were quantified using a Sysmex XT-1800i hematology analyzer. Higher blood lead levels are observed in e-waste lead-exposed preschool children. Significant relationships between high blood lead levels (exceeding current health limits) and elevated platelet count (PLT), plateletcrit (PCT), mean platelet volume (MPV), and platelet large cell ratio (P-LCR) were also uncovered. Furthermore, the median PLT and PCT levels of children from the exposed group both exceeded the respective recommended maximum reference range value, whereas the reference group did not. Location of child residence in Guiyu and BLLs were both risk factors related to platelet indices. These results suggest that high blood lead exposure from e-waste recycling may increase the risk of an amplified coagulation process through the activation of platelets in preschool children.
Effects of Electromagnetic Fields on Automated Blood Cell Measurements.
Vagdatli, Eleni; Konstandinidou, Vasiliki; Adrianakis, Nikolaos; Tsikopoulos, Ioannis; Tsikopoulos, Alexios; Mitsopoulou, Kyriaki
2014-08-01
The aim of this study is to investigate whether the electromagnetic fields associated with mobile phones and/or laptops interfere with blood cell counts of hematology analyzers. Random blood samples were analyzed on an Aperture Impedance hematology analyzer. The analysis was performed in four ways: (A) without the presence of any mobile phone or portable computer in use, (B) with mobile phones in use (B1: one mobile, B4: four mobiles), (C) with portable computers (laptops) in use (C1: one laptop, C3: three laptops), and (D) with four mobile phones and three laptops in use simultaneously. The results obtained demonstrated a statistically significant decrease in neutrophil, erythrocyte, and platelet count and an increase in lymphocyte count, mean corpuscular volume, and red blood cell distribution width, notably in the B4 group. Despite this statistical significance, in clinical practice, only the red blood cell reduction could be taken into account, as the mean difference between the A and B4 group was 60,000 cells/µL. In group D, the analyzer gave odd results after 11 measurements and finally stopped working. The combined and multiple use of mobile phones and computers affects the function of hematology analyzers, leading to false results. Consequently, the use of such electronic devices must be avoided. © 2014 Society for Laboratory Automation and Screening.
Schmitt, C.J.; Wildhaber, M.L.; Hunn, J.B.; Nash, T.; Tieger, M. N.; Steadman, B. L.
1993-01-01
The activity of the enzyme δ-aminolevulinic acid dehydratase (ALA-D) in erythrocytes has long been used as a biomarker of lead exposure in humans and waterfowl and, more recently, in fishes. The assay was tested for ALA-D activity in fishes from streams affected by lead in combination with other metals from lead-zinc mining and related activities. Fishes (mostly catostomids) were collected from sites affected by historic and current mining activities, and from sites considered to be unaffected by mining (reference sites). A group of potentially toxic elements was measured in blood and carcass samples of individual fish, as were ALA-D activity, total protein (TP), and hemoglobin (Hb) in blood. Concentrations of mining-related metals (lead, zinc, and cadmium) were significantly greater (P<0.05) in fish blood and carcass at sites affected by historic mining activities than at reference and active mining sites. When analyzed by multiple regression, ALA-D activity, Hb, and TP accounted for 66% of blood-lead and 69% of carcass-lead variability. Differences among species were small. ALA-D activity as a biomarker adequately distinguished sites affected by bioavailable environmental lead. Zinc was the only other metal that affected ALA-D activity; it appeared to ameliorate the inactivation of ALA-D by lead.
Yang, Hua; Gao, Jian; Ren, Limin; Li, Shuyu; Chen, Zhangyan; Huang, Junfang; Zhu, Shanzhu; Pan, Zhigang
2017-01-01
Knowledge-attitude-practices (KAP) significantly impact the outcome of self-management in patients with diabetes, yet the association between KAP and the combined control of the levels of blood glucose, blood pressure, and blood lipids in these patients remains uncertain. This community-based cross-sectional study was conducted from December 2014 to December 2016 on 3977 patients with type 2 diabetes in Shanghai. KAP were evaluated using the modified Chinese version of the Diabetes, Hypertension and Hyperlipidemia (DHL) Knowledge Instrument, Diabetes Empowerment Scale-Short Form (DES-SF), and Summary of Diabetes Self-Care Activities (SDSCA). Clinical and biochemical measurements were performed at each sampling site. The association between KAP scores and achieving the combined target goal was assessed by multiple logistic regression. Patients having a higher score of knowledge were more likely to achieve the combined target goal. Furthermore, a turning point of knowledge score was found that the possibility of achieving the combined target goal presented a sharp increase when the knowledge score was more than 70. However, the scores of attitude and practices had no significant relations with achieving the combined target goal. Health intervention strategies, especially increasing integrated diabetes knowledge, should be targeted to patients with type 2 diabetes in communities.
Calibration and validation of TRUST MRI for the estimation of cerebral blood oxygenation
Lu, Hanzhang; Xu, Feng; Grgac, Ksenija; Liu, Peiying; Qin, Qin; van Zijl, Peter
2011-01-01
Recently, a T2-Relaxation-Under-Spin-Tagging (TRUST) MRI technique was developed to quantitatively estimate blood oxygen saturation fraction (Y) via the measurement of pure blood T2. This technique has shown promise for normalization of fMRI signals, for the assessment of oxygen metabolism, and in studies of cognitive aging and multiple sclerosis. However, a human validation study has not been conducted. In addition, the calibration curve used to convert blood T2 to Y has not accounted for the effects of hematocrit (Hct). In the present study, we first conducted experiments on blood samples under physiologic conditions, and the Carr-Purcell-Meiboom-Gill (CPMG) T2 was determined for a range of Y and Hct values. The data were fitted to a two-compartment exchange model to allow the characterization of a three-dimensional plot that can serve to calibrate the in vivo data. Next, in a validation study in humans, we showed that arterial Y estimated using TRUST MRI was 0.837±0.036 (N=7) during the inhalation of 14% O2, which was in excellent agreement with the gold-standard Y values of 0.840±0.036 based on Pulse-Oximetry. These data suggest that the availability of this calibration plot should enhance the applicability of TRUST MRI for non-invasive assessment of cerebral blood oxygenation. PMID:21590721
Spectral feature characterization methods for blood stain detection in crime scene backgrounds
NASA Astrophysics Data System (ADS)
Yang, Jie; Mathew, Jobin J.; Dube, Roger R.; Messinger, David W.
2016-05-01
Blood stains are one of the most important types of evidence for forensic investigation. They contain valuable DNA information, and the pattern of the stains can suggest specifics about the nature of the violence that transpired at the scene. Blood spectral signatures containing unique reflectance or absorption features are important both for forensic on-site investigation and laboratory testing. They can be used for target detection and identification applied to crime scene hyperspectral imagery, and also be utilized to analyze the spectral variation of blood on various backgrounds. Non-blood stains often mislead the detection and can generate false alarms at a real crime scene, especially for dark and red backgrounds. This paper measured the reflectance of liquid blood and 9 kinds of non-blood samples in the range of 350 nm - 2500 nm in various crime scene backgrounds, such as pure samples contained in petri dish with various thicknesses, mixed samples with different colors and materials of fabrics, and mixed samples with wood, all of which are examined to provide sub-visual evidence for detecting and recognizing blood from non-blood samples in a realistic crime scene. The spectral difference between blood and non-blood samples are examined and spectral features such as "peaks" and "depths" of reflectance are selected. Two blood stain detection methods are proposed in this paper. The first method uses index to denote the ratio of "depth" minus "peak" over"depth" add"peak" within a wavelength range of the reflectance spectrum. The second method uses relative band depth of the selected wavelength ranges of the reflectance spectrum. Results show that the index method is able to discriminate blood from non-blood samples in most tested crime scene backgrounds, but is not able to detect it from black felt. Whereas the relative band depth method is able to discriminate blood from non-blood samples on all of the tested background material types and colors.
Discovery – Velcade®: A New Tool in the Fight against Multiple Myeloma
Velcade® represents a new type of anticancer drug called proteasome inhibitors. It has shown promise in the treatment of multiple myeloma, a cancer of the white blood cells. Velcade® is being studied for use in a variety of blood cancers and solid tumors.
Blood Transfusion and Donation - Multiple Languages
... All Topics All Blood Transfusion and Donation - Multiple Languages To use the sharing features on this page, please enable JavaScript. Arabic (العربية) ... Bethesda, MD 20894 U.S. Department of Health and Human Services National Institutes of Health Page last updated on 30 April 2018
Daaboul, George G; Lopez, Carlos A; Chinnala, Jyothsna; Goldberg, Bennett B; Connor, John H; Ünlü, M Selim
2014-06-24
Rapid, sensitive, and direct label-free capture and characterization of nanoparticles from complex media such as blood or serum will broadly impact medicine and the life sciences. We demonstrate identification of virus particles in complex samples for replication-competent wild-type vesicular stomatitis virus (VSV), defective VSV, and Ebola- and Marburg-pseudotyped VSV with high sensitivity and specificity. Size discrimination of the imaged nanoparticles (virions) allows differentiation between modified viruses having different genome lengths and facilitates a reduction in the counting of nonspecifically bound particles to achieve a limit-of-detection (LOD) of 5 × 10(3) pfu/mL for the Ebola and Marburg VSV pseudotypes. We demonstrate the simultaneous detection of multiple viruses in a single sample (composed of serum or whole blood) for screening applications and uncompromised detection capabilities in samples contaminated with high levels of bacteria. By employing affinity-based capture, size discrimination, and a "digital" detection scheme to count single virus particles, we show that a robust and sensitive virus/nanoparticle sensing assay can be established for targets in complex samples. The nanoparticle microscopy system is termed the Single Particle Interferometric Reflectance Imaging Sensor (SP-IRIS) and is capable of high-throughput and rapid sizing of large numbers of biological nanoparticles on an antibody microarray for research and diagnostic applications.
Factors associated with low vitamin D status of Australian alpacas.
Judson, G J; McGregor, B A; Partington, D L
2008-12-01
To investigate factors associated with low vitamin D status of alpacas at pasture in southern Australia. A 2-year survey of alpacas from two farms in South Australia and three in Victoria. Blood samples were collected from 20 to 30 alpacas on each farm on five occasions each year. Breed, gender, age and fleece colour of animals were recorded. Blood samples were assayed for plasma 2.5-hydroxycholecalciferol (25-OH D(3)) and plasma inorganic phosphorus (Pi). Data sets from 802 animal samples were analysed by multiple regression to determine variables associated with low vitamin D status of alpacas. The relationship between plasma 25-OH D(3) and plasma Pi was also investigated. Vitamin D status was significantly affected by month of sampling, with low values in late winter and high values in summer. Plasma vitamin D concentrations increased with age, were higher in alpacas with light fleeces than in those with dark fleeces and were also higher in the Suri than in the Huacaya breed. Plasma Pi concentrations were generally lower in alpacas with plasma 25-OH D(3) values < 25 nmol/L. Young alpacas with dark fleeces are most at risk from vitamin D insufficiency in late winter in southern Australia. The present study indicates that plasma Pi values are not a reliable indicator of vitamin D status of alpacas as assessed by plasma 25-OH D(3) concentrations.
Limitations of salivary and blood cortisol determinations in pigs.
Blackshaw, J K; Blackshaw, A W
1989-01-01
Blood and saliva samples were taken from groups of pigs maintained in intensive conditions. Multiple samples were taken from two unrestrained pregnant sows fitted with jugular cannulae. Single samples were taken from groups (mixed gilts and entire males; 70-90 kg) which were lightly exercised (7) or restrained (12). The rate of salivary secretion was low and collection of adequate samples took 5 min; in a number of pigs no saliva could be obtained. In order to stimulate salivary secretion, pigs (70-80 kg) were injected with pilocarpine nitrate (25 mg, subcutaneous) which produced a copious flow of saliva persisting for at least 15 min. Resting sows had higher mean levels of cortisol in plasma, ultrafiltrate and saliva than the other groups, which did not differ from each other. Within the pilocarpine group, males had a higher ultrafiltrate level of cortisol than females. In most instances salivary cortisol was significantly greater than ultrafiltrate cortisol. Ultrafiltrate and plasma cortisol were highly correlated (r = 0.883) but this correlation was low in the presence of pilocarpine (r = 0.260). Salivary cortisol was poorly correlated with either plasma (r = 0.167) or ultrafiltrate cortisol (r = 0.278) and the correlation with plasma was even lower following the administration of pilocarpine (r = 0.086). It was concluded that salivary estimates of cortisol in the pig were not usefully correlated with levels of ultrafiltrate (free) cortisol.
Parsons, Nola J; Schaefer, Adam M; van der Spuy, Stephen D; Gous, Tertius A
2015-03-25
There are few publications on the clinical haematology and biochemistry of African penguins (Spheniscus demersus) and these are based on captive populations. Baseline haematology and serum biochemistry parameters were analysed from 108 blood samples from wild, adult African penguins. Samples were collected from the breeding range of the African penguin in South Africa and the results were compared between breeding region and sex. The haematological parameters that were measured were: haematocrit, haemoglobin, red cell count and white cell count. The biochemical parameters that were measured were: sodium, potassium, chloride, calcium, inorganic phosphate, creatinine, cholesterol, serum glucose, uric acid, bile acid, total serum protein, albumin, aspartate transaminase and creatine kinase. All samples were serologically negative for selected avian diseases and no blood parasites were detected. No haemolysis was present in any of the analysed samples. Male African penguins were larger and heavier than females, with higher haematocrit, haemoglobin and red cell count values, but lower calcium and phosphate values. African penguins in the Eastern Cape were heavier than those in the Western Cape, with lower white cell count and globulin values and a higher albumin/globulin ratio, possibly indicating that birds are in a poorer condition in the Western Cape. Results were also compared between multiple penguin species and with African penguins in captivity. These values for healthy, wild, adult penguins can be used for future health and disease assessments.
Blood meal analysis of tabanid fly after it biting the rare Sumatran rhinoceros
Rovie-Ryan, Jeffrine Japning; Zainuddin, Zainal Zahari; Marni, Wahap; Ahmad, Abdul Hamid; Ambu, Laurentius N.; Payne, Junaidi
2013-01-01
Objective To demonstrate a noninvasive large mammalian genetic sampling method using blood meal obtained from a tabanid fly. Methods Blood meal was recovered from the abdomen of an engorged tabanid fly (Haematopota sp.) which was captured immediately after biting a Sumatran rhino in captivity. The blood was applied on to a Whatman FTA® blood card. Subsequent laboratory work was conducted to extract, amplify and sequence the DNA from the sample. Validation was done by sampling the hair follicles and blood samples from the rhinoceros and subjecting it to the same laboratory process. Results BLAST search and constructed phylogenetic trees confirmed the blood meal samples were indeed from the rhino. Conclusions This method could be used in the field application to noninvasively collect genetic samples. Collection of tabanids and other haematophagous arthropods (e.g. mosquitoes and ticks) and other blood-sucking parasites (e.g. leeches and worms) could also provide information on vector-borne diseases. PMID:23593586
Pennisi, Marzio; Russo, Giulia; Motta, Santo; Pappalardo, Francesco
2015-12-01
Multiple sclerosis is a disease of the central nervous system that involves the destruction of the insulating sheath of axons, causing severe disabilities. Since the etiology of the disease is not yet fully understood, the use of novel techniques that may help to understand the disease, to suggest potential therapies and to test the effects of candidate treatments is highly advisable. To this end we developed an agent based model that demonstrated its ability to reproduce the typical oscillatory behavior observed in the most common form of multiple sclerosis, relapsing-remitting multiple sclerosis. The model has then been used to test the potential beneficial effects of vitamin D over the disease. Many scientific studies underlined the importance of the blood-brain barrier and of the mechanisms that influence its permeability on the development of the disease. In the present paper we further extend our previously developed model with a mechanism that mimics the blood-brain barrier behavior. The goal of our work is to suggest the best strategies to follow for developing new potential treatments that intervene in the blood-brain barrier. Results suggest that the best treatments should potentially prevent the opening of the blood-brain barrier, as treatments that help in recovering the blood-brain barrier functionality could be less effective. Copyright © 2015 Elsevier B.V. All rights reserved.
Blood transfusion transmitted infections in multiple blood transfused patients of Beta thalassaemia.
Vidja, Prakash J; Vachhani, J H; Sheikh, S S; Santwani, P M
2011-06-01
Transfusion Transmitted Infection (TTI) continue to be a problem in many parts of world and multi-transfused patients of beta thalassaemia major are at a particularly increased risk of TTI. This study is aimed to estimate the prevalence of blood TTI in multiple blood transfused patients of beta thalassaemia major. Cross-sectional study of 200 multi-transfused patients of beta thalassaemia major, who were interviewed using a structured questionnaire and history was taken regarding sero-status of HIV (Human Immunodeficiency Virus), HBV (Hepatitis B Virus), HCV (Hepatitis C Virus) infection from their case papers. This study was conducted at the department of Pathology, M.P. Shah medical college, Jamnagar and Thalassemia ward, G.G. Hospital, Jamnagar (Gujarat, India) from March to May 2010. Out of 200 multiple blood transfused patients 7% patients were infected with TTI. Total 9 male patients and 5 female patients were infected with TTI. The seroreactivity for HIV was 3% (06/200); 1% (02/200) were males and 2% (04/200) were females. The seroreactivity for HBV was 2% (04/200) all were males. The seroreactivity for HCV was 2% (04/200); 1.5% (03/200) were males and 0.5% (01/200) was female. HIV, HBV, HCV infections are most prevalent TTI among multiple blood transfused patients of beta thalassemia major, and remains a major health problem for these patients.
Inci, Fatih; Filippini, Chiara; Baday, Murat; Ozen, Mehmet Ozgun; Calamak, Semih; Durmus, Naside Gozde; Wang, ShuQi; Hanhauser, Emily; Hobbs, Kristen S; Juillard, Franceline; Kuang, Ping Ping; Vetter, Michael L; Carocci, Margot; Yamamoto, Hidemi S; Takagi, Yuko; Yildiz, Umit Hakan; Akin, Demir; Wesemann, Duane R; Singhal, Amit; Yang, Priscilla L; Nibert, Max L; Fichorova, Raina N; Lau, Daryl T-Y; Henrich, Timothy J; Kaye, Kenneth M; Schachter, Steven C; Kuritzkes, Daniel R; Steinmetz, Lars M; Gambhir, Sanjiv S; Davis, Ronald W; Demirci, Utkan
2015-08-11
Recent advances in biosensing technologies present great potential for medical diagnostics, thus improving clinical decisions. However, creating a label-free general sensing platform capable of detecting multiple biotargets in various clinical specimens over a wide dynamic range, without lengthy sample-processing steps, remains a considerable challenge. In practice, these barriers prevent broad applications in clinics and at patients' homes. Here, we demonstrate the nanoplasmonic electrical field-enhanced resonating device (NE(2)RD), which addresses all these impediments on a single platform. The NE(2)RD employs an immunodetection assay to capture biotargets, and precisely measures spectral color changes by their wavelength and extinction intensity shifts in nanoparticles without prior sample labeling or preprocessing. We present through multiple examples, a label-free, quantitative, portable, multitarget platform by rapidly detecting various protein biomarkers, drugs, protein allergens, bacteria, eukaryotic cells, and distinct viruses. The linear dynamic range of NE(2)RD is five orders of magnitude broader than ELISA, with a sensitivity down to 400 fg/mL This range and sensitivity are achieved by self-assembling gold nanoparticles to generate hot spots on a 3D-oriented substrate for ultrasensitive measurements. We demonstrate that this precise platform handles multiple clinical samples such as whole blood, serum, and saliva without sample preprocessing under diverse conditions of temperature, pH, and ionic strength. The NE(2)RD's broad dynamic range, detection limit, and portability integrated with a disposable fluidic chip have broad applications, potentially enabling the transition toward precision medicine at the point-of-care or primary care settings and at patients' homes.
Inci, Fatih; Filippini, Chiara; Ozen, Mehmet Ozgun; Calamak, Semih; Durmus, Naside Gozde; Wang, ShuQi; Hanhauser, Emily; Hobbs, Kristen S.; Juillard, Franceline; Kuang, Ping Ping; Vetter, Michael L.; Carocci, Margot; Yamamoto, Hidemi S.; Takagi, Yuko; Yildiz, Umit Hakan; Akin, Demir; Wesemann, Duane R.; Singhal, Amit; Yang, Priscilla L.; Nibert, Max L.; Fichorova, Raina N.; Lau, Daryl T.-Y.; Henrich, Timothy J.; Kaye, Kenneth M.; Schachter, Steven C.; Kuritzkes, Daniel R.; Steinmetz, Lars M.; Gambhir, Sanjiv S.; Davis, Ronald W.; Demirci, Utkan
2015-01-01
Recent advances in biosensing technologies present great potential for medical diagnostics, thus improving clinical decisions. However, creating a label-free general sensing platform capable of detecting multiple biotargets in various clinical specimens over a wide dynamic range, without lengthy sample-processing steps, remains a considerable challenge. In practice, these barriers prevent broad applications in clinics and at patients’ homes. Here, we demonstrate the nanoplasmonic electrical field-enhanced resonating device (NE2RD), which addresses all these impediments on a single platform. The NE2RD employs an immunodetection assay to capture biotargets, and precisely measures spectral color changes by their wavelength and extinction intensity shifts in nanoparticles without prior sample labeling or preprocessing. We present through multiple examples, a label-free, quantitative, portable, multitarget platform by rapidly detecting various protein biomarkers, drugs, protein allergens, bacteria, eukaryotic cells, and distinct viruses. The linear dynamic range of NE2RD is five orders of magnitude broader than ELISA, with a sensitivity down to 400 fg/mL This range and sensitivity are achieved by self-assembling gold nanoparticles to generate hot spots on a 3D-oriented substrate for ultrasensitive measurements. We demonstrate that this precise platform handles multiple clinical samples such as whole blood, serum, and saliva without sample preprocessing under diverse conditions of temperature, pH, and ionic strength. The NE2RD’s broad dynamic range, detection limit, and portability integrated with a disposable fluidic chip have broad applications, potentially enabling the transition toward precision medicine at the point-of-care or primary care settings and at patients’ homes. PMID:26195743
Quercetin does not alter the oral bioavailability of Atorvastatin in rats.
Koritala, Rekha; Challa, Siva Reddy; Ragam, Satheesh Kumar; Geddam, Lal Babu; Venkatesh Reddy Challa, Venkatesh Reddy; Devi, Renuka; Sattenapalli, Srinu; Babu, Narendra
2015-09-01
The study was undertaken to evaluate the effect of Quercetin on the pharmacokinetics of Atorvastatin Calcium. In-vivo Pharmacokinetic studies were performed on rats in a single dose study and multiple dose study. Rats were treated with Quercetin (10 mg/kg) and Atorvastatin Calcium (20 mg/kg) orally and blood samples were collected at (0) pretreatment and 0.5, 1, 1.5, 2, 2.5, 3, 4, 8, 12, 24 hours post treatment. Plasma concentrations of Atorvastatin were estimated by HPLC method. Quercetin treatment did not significantly alter the pharmacokinetic parameters of atorvastatin like AUC(0-24), AUC(0-α) , T(max), C(max) and T(½) in both single dose and multiple dose studies of Atorvastatin Calcium. Quercetin does not alter the oral bioavailability of Atorvastatin Calcium in rats.
Zhou, Huili; Xu, Wei; Wu, Guolan; Wu, Lihua; Shentu, Jianzhong; Pan, Zhengfei; Hu, Shuai; Liu, Yang
2016-11-01
Recently a formulation of intravenous (IV) ibuprofen was developed in China for management of mild to moderate pain in patients who could not take oral medications or where intravenous administration was preferable. The aim of this study was to evaluate the pharmacokinetic properties and tolerability of single and multiple doses of ibuprofen injection in healthy Chinese volunteers. This open-label, single- and multiple-dose study was conducted in healthy Chinese volunteers. In the single-dose phase, subjects were randomized to receive a single dose of ibuprofen injection 0.2, 0.4, or 0.8 g administered as a 30-minute IV infusion with a 1-week washout between periods. Blood samples were collected at regular intervals from 0 to 12.5 hours after drug administration and were analyzed using a validated LC-MS/MS method. In the multiple-dose phase, subjects received 0.4 g ibuprofen every 6 hours for 9 doses. Blood samples were obtained before the 7th, 8th, and 9th administration to determine the Cmin at steady state; on the 9th intravenous administration, blood samples were also collected for 12.5 hours after drug administration. Pharmacokinetic parameters were estimated using a noncompartmental model. Tolerability was determined using clinical evaluation and monitoring of adverse events (AEs). A total of 12 healthy male (n = 6) and female (n = 6) Chinese volunteers were enrolled and completed the trial. After IV administration of single dose, the mean (SD) Cmax value increased from 35.77 (6.98) to 117.12 (19.78) µg/mL, and the mean (SD) AUC0-t value increased from 67.63 (10.30) to 230.50 (33.55) µg×h/mL in the range of 0.2-g to 0.8-g dose. The terminal half-life in plasma was ~ 2.0 hours. After IV administration of 9 doses of ibuprofen 400 mg every 6 hours, the mean (SD) Cmax was 66.49 (8.49) µg/mL, the AUC0-t was 135.65 (26.91) µg×h/mL, the t1/2 was 2.14 (0.34) hours, the Cl/F was 3.34 (0.68) L/h, and the Vz/F was 10.32 (2.69) L, which were comparable with those after single dosing. The accumulation index was 1.17 (0.06), and the fluctuation was 304.0 (57.7) %. Results of the t-tests of Cmax and AUC found no significant differences between the male and female groups. No serious AEs were reported, and there were no discontinuations due to AEs. The pharmacokinetics of ibuprofen exhibited dose-related kinetics from the 0.2- to the 0.8-g dose. After multiple doses, the pharmacokinetic parameters of ibuprofen were consistent with those after single doses. There was no accumulation in ibuprofen exposure in healthy Chinese between multiple doses and single dose. At the doses studied, ibuprofen appeared to be well tolerated in these healthy volunteers. .
Vanschoonbeek, Kristof; Thomassen, Bregje J W; Senden, Joan M; Wodzig, Will K W H; van Loon, Luc J C
2006-04-01
In vitro and in vivo animal studies have reported strong insulin-like or insulin-potentiating effects after cinnamon administration. Recently, a human intervention study showed that cinnamon supplementation (1 g/d) strongly reduced fasting blood glucose concentration (30%) and improved the blood lipid profile in patients with type 2 diabetes. The objective of this study was to investigate the effects of cinnamon supplementation on insulin sensitivity and/or glucose tolerance and blood lipid profile in patients with type 2 diabetes. Therefore, a total of 25 postmenopausal patients with type 2 diabetes (aged 62.9 +/- 1.5 y, BMI 30.4 +/- 0.9 kg/m2) participated in a 6-wk intervention during which they were supplemented with either cinnamon (Cinnamomum cassia, 1.5 g/d) or a placebo. Before and after 2 and 6 wk of supplementation, arterialized blood samples were obtained and oral glucose tolerance tests were performed. Blood lipid profiles and multiple indices of whole-body insulin sensitivity were determined. There were no time x treatment interactions for whole-body insulin sensitivity or oral glucose tolerance. The blood lipid profile of fasting subjects did not change after cinnamon supplementation. We conclude that cinnamon supplementation (1.5 g/d) does not improve whole-body insulin sensitivity or oral glucose tolerance and does not modulate blood lipid profile in postmenopausal patients with type 2 diabetes. More research on the proposed health benefits of cinnamon supplementation is warranted before health claims should be made.
Arage, Getachew; Ibrahim, Seada; Adimasu, Endeshaw
2017-07-19
Blood donation has remained a challenge in developing countries, like Ethiopia. In Ethiopia there is a high reliance on family surrogate and waged blood donors which carries an attendant increased risk of transfusion transmissible infection. Health workers are expected to practice blood donation so as to create a good image to the public. A study on blood donation behavior may improve successful implementation of the blood donation programs. An institution based cross-sectional study was deployed from January to June 2015. An aggregate of 427 health workers were included in the study by using simple random sampling technique. Data were collected by using pre tested and structured questionnaire via self-administrated method. Descriptive and summary statistics were employed. Bivariate and multiple logistic regressions were computed. Odds ratios and their 95% confidence intervals were calculated to determine the level of significance. A total of 427 participants were included in the final analysis (response rate = 100%). Among these participants, 33.2% of them practice blood donation. Age above 25 years [AOR = 1.8 (95% CI 1.1, 3.0)], health professionals' knowledge of blood donation [AOR = 1.9 (95% CI 1.1, 3.1)], health professionals' attitude towards blood donation [AOR = 3.0, 95% CI 1. 8, 4.9)], and the presence of family members or relatives who received blood [AOR = 5.4, 95% CI 3.7, 8.7)] were significantly and independently associated with blood donation behavior of health professionals. Blood donation practice of health professionals in this study was found to be low as compared to other studies conducted in developing countries. Health professionals' knowledge, attitude, age and the presence of family members or relatives who received blood before were independently associated with blood donation practice. Thus, awareness has to be created for health professionals to improve blood donation practices.
Song, Yoojun; Lee, Chae-Kwan; Kim, Kun-Hyung; Lee, Jong-Tae; Suh, Chunhui; Kim, Se-Yeong; Kim, Jeong-Ho; Son, Byung-Chul; Kim, Dae-Hwan; Lee, Sangyoon
2016-01-01
This study investigated the concentration of total mercury (THg) in maternal blood, cord blood, and breast milk, and its association with dietary factors. A total of 127 pregnant women in Busan, Korea were recruited. Maternal blood, cord blood, and breast milk were collected at 36 weeks of gestation, at delivery, and at one week after birth, respectively. Information about dietary habits and other factors were obtained from each subject. The mean THg concentrations in maternal blood, cord blood, and breast milk were 3.12±1.36 μg/L, 5.46±2.41 μg/L, and 0.91±2.08 μg/L, respectively. Positive correlations were found between log-transformed THg concentrations in maternal blood and cord blood (r=0.829, p<0.001), and between maternal blood and breast milk (r=0.296, p=0.001). Multiple linear regression analysis showed that the log-transformed concentration of THg in maternal blood was positively correlated with fish consumption (β=0.345, p<0.0001) and negatively correlated with bean consumption (β=-0.055, p=0.048). Fish consumption (β=0.482, p<0.0001) and maternal age (β=0.025, p=0.033) were positively associated with the concentration of THg in cord blood, while negative correlations were found for bean consumption (β=-0.134, p=0.027) and parity (β=-0.172, p=0.015). Beef consumption (β=0.031, p=0.007) was positively associated with log-transformed THg concentrations in breast milk, while negative correlations were found for bean consumption (β=-0.019, p=0.003) and maternal age (β=-0.083, p=0.004). Our study found that both the dietary and demographic factors differently affected to THg concentrations among samples of maternal blood, cord blood, and breast milk.
[Rapid identification of 22 abused drugs and organophosphorus pesticides in blood by LC-MS/MS].
Liu, Hong-tao; Ma, An-de
2009-08-01
To develop a method for rapid identification of 22 abused drugs and organophosphorus pesticides in the blood. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) in multiple-reaction monitoring mode (MRM) was employed for detecting the drugs and pesticides in the blood. The MRM database and criteria for identification were established, and ethyl acetate was used for extraction of the drugs. After 3 rounds of extractions of the blood sample (1 mL) using 2 mL ethyl acetate, the extract was vortexed for 3 min and centrifuged at 5000 r/min. Each organic phase was combined and evaporated by gentle N2 gas. The residue was re-dissolved in 100 L mobile phase, from which 5 L was taken for LC-MS/MS detection. The detection of the 22 target compounds could be completed within 10 min. The limit of detection of the target compound ranged from 0.03 to 6.00 ng/ml. Satisfactory results were obtained in proficiency testing program organized by China National Accreditation Service for Conformity Assessment. The method we established is rapid, selective and sensitive for detecting the 22 abused drugs and organophosphorus pesticides.
NASA Astrophysics Data System (ADS)
Lee, Hoyoon; Kim, Gyehyu; Choi, Seawhan; Shin, Sehyun; Korea University Department of Mechanical Engineering Team
2015-11-01
Platelet is a crucial blood cell on hemostasis. As platelet exposed to high shear stress, it can be activated showing morphological and functional changes to stop bleeding. When platelet is abnormal, there is high risk of cardiovascular diseases. Thus, quick and precise assay for platelet function is important in clinical treatment. In this study, we design a microfluidic system, which can test platelet function exposed with the stimulation of shear and agonists. The microfluidic system consists of three parts: 1) a shear mechanism with rotating stirrer; 2) multiple microchannels to flow samples and to stop; 3) camera-interfaced migration distance(MD) analyzing system. When sheared blood is driven by pressure through the microchannel, shear-activated platelets adhere to a collagen-coated surface, causing blood flow to significantly slow and eventually stop. As the micro-stirrer speed increases, MD decreases exponentially at first, but it increases beyond a critical rpm after all. These results are coincident with data measured by FACS flowcytometry. These results imply that the present system could quantitatively measure the degree of activation, aggregation and adhesion of platelets and that blood MD is potent index for measuring the shear-dependence of platelet function.
Yousefi, Siavash; Qin, Jia; Dziennis, Suzan; Wang, Ruikang K.
2014-01-01
Abstract. Cutaneous wound healing consists of multiple overlapping phases starting with blood coagulation following incision of blood vessels. We utilized label-free optical coherence tomography and optical microangiography (OMAG) to noninvasively monitor healing process and dynamics of microcirculation system in a mouse ear pinna wound model. Mouse ear pinna is composed of two layers of skin separated by a layer of cartilage and because its total thickness is around 500 μm, it can be utilized as an ideal model for optical imaging techniques. These skin layers are identical to human skin structure except for sweat ducts and glands. Microcirculatory system responds to the wound injury by recruiting collateral vessels to supply blood flow to hypoxic region. During the inflammatory phase, lymphatic vessels play an important role in the immune response of the tissue and clearing waste from interstitial fluid. In the final phase of wound healing, tissue maturation, and remodeling, the wound area is fully closed while blood vessels mature to support the tissue cells. We show that using OMAG technology allows noninvasive and label-free monitoring and imaging each phase of wound healing that can be used to replace invasive tissue sample histology and immunochemistry technologies. PMID:25036212
Nam, Su-Hyun; Lee, Yun-Ah; Rho, Jun-Seung
2015-01-01
Aim. Metabolic syndrome is characterized by a cluster of atherosclerotic cardiovascular risk factors. The cardioankle vascular index (CAVI) reflects arterial stiffness and may be used as an indicator of atherosclerotic cardiovascular disease. In this study, we investigated the association of CAVI with metabolic syndrome. Methods. A total of 1,144 adults were included in this study. We measured CAVIs and examined blood samples to identify metabolic syndrome according to WHO Asia Pacific criteria and NCEP-ATPIII criteria. AST, ALT, r-GTP, BUN, creatinine, high sensitivity C-reactive protein, and uric acid were also measured. Results. CAVI values were significantly higher in subjects with metabolic syndrome than those without metabolic syndrome and increased according to the number of metabolic syndrome components present. Subjects with high fasting blood sugar levels or high blood pressure showed high CAVI values. Multiple regression analysis showed that age, sex, diastolic blood pressure, and uric acid were independent predictors of CAVI. Conclusion. Subjects with metabolic syndrome had high CAVIs, which indicated arterial stiffness, and were closely associated with an increase in the number of metabolic risk factors. The individual risk factors for metabolic syndrome have the synergistic effect of elevating arterial stiffness in asymptomatic Korean population. PMID:26273666
Hodnett, Darragh; Wood, David M; Raja, Kishor; Dargan, Paul I; Shah, Anoop D
2012-02-01
The trace elements cobalt (Co), chromium (Cr), manganese (Mn) and nickel (Ni) are normally present at low concentrations in blood. There has been a concern that stainless steel venepuncture needles typically used for collection of blood samples may contaminate these samples, leading to the masking of deficiency states or causing potential clinical confusion as to whether an individual has a "toxic" concentration. To determine whether there is any difference between the concentrations of the trace elements obtained by different methods of blood sampling. We took blood samples using a standard venepuncture needle, a "butterfly" winged infusion needle (three consecutive samples) and a plastic intravenous cannula (three consecutive samples) from 10 healthy volunteers. We measured the concentrations of Co, Cr, Mn and Ni in the samples using Inductively Coupled Plasma Mass Spectrometry, and used analysis of variance (ANOVA) to investigate if there was any difference between the methods of blood sampling. The mean ± standard deviation blood metal concentrations were: Co 0.33 ± 0.2 μg/l, Cr 2.43 ± 1.55 μg/l, Mn 8.07 ± 7.74 μg/l and Ni 10.4 ± 4.69 μg/l. There was considerable variation between blood metal concentrations of individual subjects and a few sporadic high values. By ANOVA, there was no significant difference between the metal concentrations measured using different methods of blood collection. It is not necessary to routinely use a plastic cannula for blood sampling for trace element analysis. However, it is possible that sporadic contamination due to stainless steel needles may occur, so we would recommend that unexpected high concentrations are verified by taking a second sample taken through a plastic cannula.
Holst, Birgitte; Hau, Jann; Rozell, Björn; Abelson, Klas Stig Peter
2014-01-01
Retro-bulbar sinus puncture and facial vein phlebotomy are two widely used methods for blood sampling in laboratory mice. However, the animal welfare implications associated with these techniques are currently debated, and the possible physiological and pathological implications of blood sampling using these methods have been sparsely investigated. Therefore, this study was conducted to assess and compare the impacts of blood sampling by retro-bulbar sinus puncture and facial vein phlebotomy. Blood was obtained from either the retro-bulbar sinus or the facial vein from male C57BL/6J mice at two time points, and the samples were analyzed for plasma corticosterone. Body weights were measured at the day of blood sampling and the day after blood sampling, and the food consumption was recorded automatically during the 24 hours post-procedure. At the end of study, cheeks and orbital regions were collected for histopathological analysis to assess the degree of tissue trauma. Mice subjected to facial vein phlebotomy had significantly elevated plasma corticosterone levels at both time points in contrast to mice subjected to retro-bulbar sinus puncture, which did not. Both groups of sampled mice lost weight following blood sampling, but the body weight loss was higher in mice subjected to facial vein phlebotomy. The food consumption was not significantly different between the two groups. At gross necropsy, subcutaneous hematomas were found in both groups and the histopathological analyses revealed extensive tissue trauma after both facial vein phlebotomy and retro-bulbar sinus puncture. This study demonstrates that both blood sampling methods have a considerable impact on the animals' physiological condition, which should be considered whenever blood samples are obtained. PMID:25426941
Agreement in DNA methylation levels from the Illumina 450K array across batches, tissues, and time
Forest, Marie; O'Donnell, Kieran J.; Voisin, Greg; Gaudreau, Helene; MacIsaac, Julia L.; McEwen, Lisa M.; Silveira, Patricia P.; Steiner, Meir; Kobor, Michael S.; Meaney, Michael J.; Greenwood, Celia M.T.
2018-01-01
ABSTRACT Epigenome-wide association studies (EWAS) have focused primarily on DNA methylation as a chemically stable and functional epigenetic modification. However, the stability and accuracy of the measurement of methylation in different tissues and extraction types is still being actively studied, and the longitudinal stability of DNA methylation in commonly studied peripheral tissues is of great interest. Here, we used data from two studies, three tissue types, and multiple time points to assess the stability of DNA methylation measured with the Illumina Infinium HumanMethylation450 BeadChip array. Redundancy analysis enabled visual assessment of agreement of replicate samples overall and showed good agreement after removing effects of tissue type, age, and sex. At the probe level, analysis of variance contrasts separating technical and biological replicates clearly showed better agreement between technical replicates versus longitudinal samples, and suggested increased stability for buccal cells versus blood or blood spots. Intraclass correlations (ICCs) demonstrated that inter-individual variability is of similar magnitude to within-sample variability at many probes; however, as inter-individual variability increased, so did ICC. Furthermore, we were able to demonstrate decreasing agreement in methylation levels with time, despite a maximal sampling interval of only 576 days. Finally, at 6 popular candidate genes, there was a large range of stability across probes. Our findings highlight important sources of technical and biological variation in DNA methylation across different tissues over time. These data will help to inform longitudinal sampling strategies of future EWAS. PMID:29381404
Garty, Guy; Chen, Youhua; Turner, Helen C; Zhang, Jian; Lyulko, Oleksandra V; Bertucci, Antonella; Xu, Yanping; Wang, Hongliang; Simaan, Nabil; Randers-Pehrson, Gerhard; Lawrence Yao, Y; Brenner, David J
2011-08-01
Over the past five years the Center for Minimally Invasive Radiation Biodosimetry at Columbia University has developed the Rapid Automated Biodosimetry Tool (RABiT), a completely automated, ultra-high throughput biodosimetry workstation. This paper describes recent upgrades and reliability testing of the RABiT. The RABiT analyses fingerstick-derived blood samples to estimate past radiation exposure or to identify individuals exposed above or below a cut-off dose. Through automated robotics, lymphocytes are extracted from fingerstick blood samples into filter-bottomed multi-well plates. Depending on the time since exposure, the RABiT scores either micronuclei or phosphorylation of the histone H2AX, in an automated robotic system, using filter-bottomed multi-well plates. Following lymphocyte culturing, fixation and staining, the filter bottoms are removed from the multi-well plates and sealed prior to automated high-speed imaging. Image analysis is performed online using dedicated image processing hardware. Both the sealed filters and the images are archived. We have developed a new robotic system for lymphocyte processing, making use of an upgraded laser power and parallel processing of four capillaries at once. This system has allowed acceleration of lymphocyte isolation, the main bottleneck of the RABiT operation, from 12 to 2 sec/sample. Reliability tests have been performed on all robotic subsystems. Parallel handling of multiple samples through the use of dedicated, purpose-built, robotics and high speed imaging allows analysis of up to 30,000 samples per day.
Garty, Guy; Chen, Youhua; Turner, Helen; Zhang, Jian; Lyulko, Oleksandra; Bertucci, Antonella; Xu, Yanping; Wang, Hongliang; Simaan, Nabil; Randers-Pehrson, Gerhard; Yao, Y. Lawrence; Brenner, David J.
2011-01-01
Purpose Over the past five years the Center for Minimally Invasive Radiation Biodosimetry at Columbia University has developed the Rapid Automated Biodosimetry Tool (RABiT), a completely automated, ultra-high throughput biodosimetry workstation. This paper describes recent upgrades and reliability testing of the RABiT. Materials and methods The RABiT analyzes fingerstick-derived blood samples to estimate past radiation exposure or to identify individuals exposed above or below a cutoff dose. Through automated robotics, lymphocytes are extracted from fingerstick blood samples into filter-bottomed multi-well plates. Depending on the time since exposure, the RABiT scores either micronuclei or phosphorylation of the histone H2AX, in an automated robotic system, using filter-bottomed multi-well plates. Following lymphocyte culturing, fixation and staining, the filter bottoms are removed from the multi-well plates and sealed prior to automated high-speed imaging. Image analysis is performed online using dedicated image processing hardware. Both the sealed filters and the images are archived. Results We have developed a new robotic system for lymphocyte processing, making use of an upgraded laser power and parallel processing of four capillaries at once. This system has allowed acceleration of lymphocyte isolation, the main bottleneck of the RABiT operation, from 12 to 2 sec/sample. Reliability tests have been performed on all robotic subsystems. Conclusions Parallel handling of multiple samples through the use of dedicated, purpose-built, robotics and high speed imaging allows analysis of up to 30,000 samples per day. PMID:21557703
Recombination Origin of Retrovirus XMRV | Center for Cancer Research
Xenotropic murine leukemia virus–related virus (XMRV) was first reported in samples from a human prostate tumor in 2006, and, at that time, claims were made that XMRV infection rates ranged from 6 to 27 percent of human prostate cancers. Later research reported XMRV in the blood of 67 percent of people with chronic fatigue syndrome (CFS). When follow-up studies failed to detect XMRV in multiple sets of specimens from people with prostate cancer or CFS and healthy controls, the original reports came under closer scrutiny.
Biomarker Surrogates Do Not Accurately Predict Sputum Eosinophils and Neutrophils in Asthma
Hastie, Annette T.; Moore, Wendy C.; Li, Huashi; Rector, Brian M.; Ortega, Victor E.; Pascual, Rodolfo M.; Peters, Stephen P.; Meyers, Deborah A.; Bleecker, Eugene R.
2013-01-01
Background Sputum eosinophils (Eos) are a strong predictor of airway inflammation, exacerbations, and aid asthma management, whereas sputum neutrophils (Neu) indicate a different severe asthma phenotype, potentially less responsive to TH2-targeted therapy. Variables such as blood Eos, total IgE, fractional exhaled nitric oxide (FeNO) or FEV1% predicted, may predict airway Eos, while age, FEV1%predicted, or blood Neu may predict sputum Neu. Availability and ease of measurement are useful characteristics, but accuracy in predicting airway Eos and Neu, individually or combined, is not established. Objectives To determine whether blood Eos, FeNO, and IgE accurately predict sputum eosinophils, and age, FEV1% predicted, and blood Neu accurately predict sputum neutrophils (Neu). Methods Subjects in the Wake Forest Severe Asthma Research Program (N=328) were characterized by blood and sputum cells, healthcare utilization, lung function, FeNO, and IgE. Multiple analytical techniques were utilized. Results Despite significant association with sputum Eos, blood Eos, FeNO and total IgE did not accurately predict sputum Eos, and combinations of these variables failed to improve prediction. Age, FEV1%predicted and blood Neu were similarly unsatisfactory for prediction of sputum Neu. Factor analysis and stepwise selection found FeNO, IgE and FEV1% predicted, but not blood Eos, correctly predicted 69% of sputum Eos
Sidhu, Shailpreet K; Malhotra, Sita; Devi, Pushpa; Tuli, Arpandeep K
2016-12-01
Coagulase negative Staphylococcus (CoNS) is frequently isolated from blood cultures but their significance is difficult to interpret. CoNS bacteria which are often previously dismissed as culture contaminants are attracting greater importance as true pathogens in the past decades. Clinical evaluation of these isolates suggests that although there is a relative increase of CoNS associated bloodstream infections in recent years, the microorganisms still remain the most common contaminants in blood cultures. The objective of this study was to determine the significance of CoNS isolated from blood cultures. A retrospective study was conducted to evaluate the rate of contamination in blood cultures in a tertiary care hospital. The paired specimens of blood were cultured using conventional culture methods and the isolates of coagulase negative staphylococci were identified by standard methodology. Clinical data, laboratory indices, microbiological parameters and patient characteristics were analyzed. Of 3503 blood samples, CoNS were isolated from blood culture of 307 patients (8.76%). The isolates were reported as true pathogens of bloodstream infections in only 74 out of 307 cases (24.1%). In the vast majority, 212 of 307 (69.0%), they were mere blood culture contaminants and reported as insignificant/contaminant. Determining whether a growth in the blood culture is a pathogen or a contaminant is a critical issue and multiple parameters have to be considered before arriving at a conclusion. Ideally, the molecular approach is for the most part a consistent method in determining the significant isolates of CoNS. However, in countries with inadequate resources, species identification and antibiogram tests are recommended when determining significance of these isolates.
Infrared Spectroscopy of Blood for Disease Identification
NASA Astrophysics Data System (ADS)
Pichardo, J. L.; Huerta-Franco, R.; Álvarez, R. R.; Bernal, J.; Gutiérrez-Juárez, G.; Palomares-Anda, P.
2003-09-01
Total reflectance attenuated infrared Fourier transform spectroscopy was used to analyze blood samples. Plasma and red blood cells were separated by centrifugation. The spectra were recorded from 200 to 4000 cm-1 under the same conditions for all samples. Samples of healthy donors were compared with those patients with different diseases (polycythemia and high blood pressure). Patients were under medical control at the time of the study. However, the preliminary results reveal that blood samples from healthy subjects had different infrared spectra compared to the non healthy patients.
Araujo, Pedro; Bjørkkjær, Tormod; Frøyland, Livar; Waagbø, Rune
2018-02-01
It studies on the factors that affect the stability of fatty acid profiles from human blood specimens are generally performed by evaluating the effect of a single factor on an individual fatty acid and excluding a considerable amount of data from the total fatty acid profiles. The stability of fatty acids from plasma, serum and red blood cells (RBC) was evaluated in terms of time, temperature, antioxidant and thawing. The fatty acids were methylated and analyzed by gas chromatography. The large volume of data is evaluated simultaneously and automatically by observing an Excel-based colour scale that indicates whether the fatty acid profiles have changed significantly as a result of the storage time (0-52weeks), temperature (-20°C/-80°C), butylated hydroxytoluene (BHT) antioxidant (presence/absence) or thawing (single/multiple). Fatty acids from plasma were stable at both temperatures (-20°C/-80°C) regardless of BHT. Fatty acids from serum without BHT degrades faster at -80°C than -20°C and fatty acids from RBC without BHT degrades faster at -20°C than -80°C. Addition of BHT inhibits this effect in serum and RBC. Multiple thawing of RBC without BHT demonstrated that polyunsaturated fatty acids were generally more susceptible for changes at -80°C than at -20°C while BHT prevents partially this effect. This study draws attention to the importance of pre-analytical considerations when storing blood samples in biobanks and the need of careful judgments when analyzing fatty acids profiles. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Vega, Claudia M; Godoy, José M; Barrocas, Paulo R G; Gonçalves, Rodrigo A; De Oliveira, Beatriz F A; Jacobson, Ludmilla V; Mourão, Dennys S; Hacon, Sandra S
2017-01-01
Selenium (Se) is an essential micronutrient that exerts multiple functions in the organism, and both its deficiency and excess can cause health impairments. Thus, it is important to monitor its levels in the population, especially in vulnerable groups, such as children from the Brazilian Amazon region, where there is a lack of information in this regard. The aim of this research was to study Se levels in the whole blood of children and teenagers (5-16 years old) from two riparian communities at the Madeira River (Cuniã RESEX and Belmont). Se level variations related to the communities' location, seasonality, diet, and body mass index (BMI) were assessed. Blood samples were collected in both communities for Se determinations, using ICP-MS and hemogram analyses, during May and September of 2011. Food frequency questionnaires were applied to assess consumption rates of specific food items. Non-parametric tests and linear multiple regressions were applied in the data analyses. Median Se levels were significantly higher during May (Cuniã RESEX 149 μg L -1 ; Belmont 85 μg L -1 ) compared to September (Cuniã RESEX 79 μg L -1 ; Belmont 53 μg L -1 ). No significant differences were found between the communities regarding BMI measurements and anemia prevalence. However, Se blood levels were significantly higher at the Cuniã RESEX compared to Belmont. In addition, the former showed higher fish and Brazil nut intakes, which may be the main Se sources for this community. These results contribute to a better understanding of Se reference levels for children and teenagers of Western Amazon riparian communities.
Elias, S M; Hashim, Z; Marjan, Z M; Abdullah, A S; Hashim, J H
2007-01-01
A cross-sectional study was conducted to identify the relationship between blood lead concentration and nutritional status among primary school children in Kuala Lumpur. A total of 225 Malay students, 113 male and 112 female, aged 6.3 to 9.8 were selected through a stratified random sampling method. The random blood samples were collected and blood lead concentration was measured by a Graphite Furnace Atomic Absorption Spectrophotometer. The nutrient intake was determined by the 24-hour Dietary Recall method and Food Frequency Questionnaire. An anthropometric assessment was reported according to growth indices (z-scores of weight-for-age, height-for-age, and weight-for-height). The mean blood lead concentration was low (3.4 +/- 1.91 ug/dL) and was significantly different between gender. Only 14.7% of the respondents fulfilled the daily energy requirement. The protein and iron intakes were adequate for a majority of the children. However, 34.7% of the total children showed inadequate intake of calcium. The energy, protein, fat and carbohydrate intakes were significantly different by gender, that is, males had better intake than females. Majority of respondents had normal mean z-score of growth indices. Ten percent of the respondents were underweight, 2.8% wasted and 5.4% stunted. Multiple linear regression showed inverse significant relationships between blood lead concentration with children's age (beta = -0.647, p < 0.001) and per capita income (beta = -0.001, p = 0.018). There were inverse significant relationships between blood lead concentration with children's age (beta = -0.877, p = 0.001) and calcium intake (beta = -0.011, p = 0.014) and positive significant relationship with weight-for-height (beta = 0.326, p = 0.041) among those with inadequate calcium intake. Among children with inadequate energy intake, children's age (beta = -0.621, p < 0.001), per capita income (beta = -0.001, p = 0.025) and protein intake (beta = -0.019, p = 0.027) were inversely and significantly related with blood lead concentration. In conclusion, nutritional status might affect the children's absorption of lead and further investigation is required for confirmation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Butler Walker, Jody; Houseman, Jan; Seddon, Laura
Maternal and umbilical cord blood levels of mercury (Hg), lead (Pb), cadmium (Cd), and the trace elements copper (Cu), zinc (Zn), and selenium (Se) are reported for Inuit, Dene/Metis, Caucasian, and Other nonaboriginal participants from Arctic Canada. This is the first human tissue monitoring program covering the entire Northwest Territories and Nunavut for multiple contaminants and establishes a baseline upon which future comparisons can be made. Results for chlorinated organic pesticides and PCBs for these participants have been reported elsewhere. Between May 1994 and June 1999, 523 women volunteered to participate by giving their written informed consent, resulting in themore » collection of 386 maternal blood samples, 407 cord samples, and 351 cord:maternal paired samples. Geometric mean (GM) maternal total mercury (THg) concentrations ranged from 0.87{mu}g/L (SD=1.95) in the Caucasian group of participants (n=134) to 3.51{mu}g/L (SD=8.30) in the Inuit group (n=146). The GM of the Inuit group was 2.6-fold higher than that of the Dene/Metis group (1.35{mu}g/L, SD=1.60, n=92) and significantly higher than those of all other groups (P<0.0001). Of Inuit women participants, 3% (n=4) were within Health Canada's level of concern range (20-99{mu}g/L) for methylmercury (MeHg) exposure. Of Inuit and Dene/Metis cord samples, 56% (n=95) and 5% (n=4), respectively, exceeded 5.8{mu}g/L MeHg, the revised US Environmental Protection Agency lower benchmark dose. GM maternal Pb was significantly higher in Dene/Metis (30.9{mu}g/L or 3.1{mu}g/dL; SD=29.1{mu}g/L) and Inuit (31.6{mu}g/L, SD=38.3) participants compared with the Caucasian group (20.6{mu}g/L, SD=17.9) (P<0.0001). Half of all participants were smokers. GM blood Cd in moderate smokers (1-8 cigarettes/day) and in heavy smokers (>8 cigarettes/day) was 7.4-fold higher and 12.5-fold higher, respectively, than in nonsmokers. The high percentage of smokers among Inuit (77%) and Dene/Metis (48%) participants highlights the need for ongoing public health action directed at tobacco prevention, reduction, and cessation for women of reproductive age. Pb and THg were detected in more than 95% of all cord blood samples, with GMs of 21 {mu}g/L and 2.7{mu}g/L, respectively, and Cd was detected in 26% of all cord samples, with a GM of 0.08{mu}g/L. Cord:maternal ratios from paired samples ranged from 0.44 to 4.5 for THg, from 0.5 to 10.3 for MeHg, and 0.1 to 9.0 for Pb. On average, levels of THg, MeHg, and Zn were significantly higher in cord blood than in maternal blood (P<0.0001), whereas maternal Cd, Pb, Se, and Cu levels were significantly higher than those in cord blood (P<0.0001). There was no significant relationship between methylmercury and selenium for the range of MeHg exposures in this study. Ongoing monitoring of populations at risk and traditional food species, as well as continued international efforts to reduce anthropogenic sources of mercury, are recommended.« less
Alqahtani, Saeed A; Alsultan, Abdullah S; Alqattan, Hussain M; Eldemerdash, Ahmed; Albacker, Turki B
2018-04-23
The purpose of this study was to investigate the population pharmacokinetics of vancomycin in patients undergoing open heart surgery. In this observational pharmacokinetic study, multiple blood samples were drawn over a 48-h period of intravenous vancomycin in patients who were undergoing open heart surgery. Blood samples were analysed using the Architect i4000SR Immunoassay Analyzer. Population pharmacokinetic models were developed using Monolix 4.4 software. Pharmacokinetic-pharmacodynamic (PK-PD) simulations were performed to explore the ability of different dosage regimens to achieve the pharmacodynamic targets. One-hundred and sixty-eight blood samples were analysed from 28 patients. The pharmacokinetics of vancomycin was best described by a two-compartment model with between-subject variability in CL, V of the central compartment, and V of the peripheral compartment. CL and central compartment V of vancomycin were related to CL CR , body weight, and albumin concentration. Dosing simulations showed that standard dosing regimens of 1 and 1.5 g failed to achieve the PK-PD target of AUC 0--24 /MIC > 400 for an MIC of 1 mg/L, while high weight-based dosing regimens were able to achieve the PK-PD target. In summary, administration of standard doses of 1 and 1.5 g of vancomycin two times daily provided inadequate antibiotic prophylaxis in patients undergoing open heart surgery. The same findings were obtained when 15 mg/kg and 20 mg/kg doses of vancomycin were administered. Achieving the PK-PD target required higher doses (25 mg/kg and 30 mg/kg) of vancomycin. Copyright © 2018 American Society for Microbiology.
Kunze-Szikszay, Nils; Krack, Lennart A; Wildenauer, Pauline; Wand, Saskia; Heyne, Tim; Walliser, Karoline; Spering, Christopher; Bauer, Martin; Quintel, Michael; Roessler, Markus
2016-10-10
Hyperfibrinolysis (HF) is a major contributor to coagulopathy and mortality in trauma patients. This study investigated (i) the rate of HF during the pre-hospital management of patients with multiple injuries and (ii) the effects of pre-hospital tranexamic acid (TxA) administration on the coagulation system. From 27 trauma patients with pre-hospital an estimated injury severity score (ISS) ≥16 points blood was obtained at the scene and on admission to the emergency department (ED). All patients received 1 g of TxA after the first blood sample was taken. Rotational thrombelastometry (ROTEM) was performed for both blood samples, and the results were compared. HF was defined as a maximum lysis (ML) >15 % in EXTEM. The median (min-max) ISS was 17 points (4-50 points). Four patients (15 %) had HF diagnosed via ROTEM at the scene, and 2 patients (7.5 %) had HF diagnosed via ROTEM on admission to the ED. The median ML before TxA administration was 11 % (3-99 %) vs. 10 % after TxA administration (4-18 %; p > 0.05). TxA was administered 37 min (10-85 min) before ED arrival. The ROTEM results before and after TxA administration did not significantly differ. No adverse drug reactions were observed after TxA administration. HF can be present in severely injured patients during pre-hospital care. Antifibrinolytic therapy administered at the scene is a significant time saver. Even in milder trauma fibrinogen can be decreased to critically low levels. Early administration of TxA cannot reverse or entirely stop this decrease. The pre-hospital use of TxA should be considered for severely injured patients to prevent the worsening of trauma-induced coagulopathy and unnecessarily high fibrinogen consumption. ClinicalTrials.gov ID NCT01938768 (Registered 5 September 2013).
Zhang, Yinfeng; Luo, Haining; Zhang, Yunshan
2015-12-01
To establish a novel HLA genotyping method for preimplantation genetic diagnonis (PGD) using multiple displacement amplification-polymerase chain reaction-sequencing based technique (MDA-PCR-SBT). Peripheral blood samples and 76 1PN, 2PN, 3PN discarded embryos from 9 couples were collected. The alleles of HLA-A, B, DR loci were detected from the MDA product with the PCR-SBT method. The HLA genotypes of the parental peripheral blood samples were analyzed with the same protocol. The genotypes of specific HLA region were evaluated for distinguishing the segregation of haplotypes among the family members, and primary HLA matching was performed between the embryos. The 76 embryos were subjected to MDA and 74 (97.4%) were successfully amplified. For the 34 embryos from the single blastomere group, the amplification rate was 94.1%, and for the 40 embryos in the two blastomeres group, the rate was 100%. The dropout rates for DQ allele and DR allele were 1.3% and 0, respectively. The positive rate for MDA in the single blastomere group was 100%, with the dropout rates for DQ allele and DR allele being 1.5% and 0, respectively. The positive rate of MDA for the two blastomere group was 100%, with the dropout rates for both DQ and DR alleles being 0. The recombination rate of fetal HLA was 20.2% (30/148). Due to the improper classification and abnormal fertilized embryos, the proportion of matched embryos HLA was 20.3% (15/74),which was lower than the theoretical value of 25%. PGD with HLA matching can facilitate creation of a HLA-identical donor (saviour child) for umbilical cord blood or bone marrow stem cells for its affected sibling with a genetic disease. Therefore, preimplantation HLA matching may provide a tool for couples desiring to conceive a potential donor progeny for transplantation for its sibling with a life-threatening disorder.
Beckmen, Kimberlee B; Keogh, Mandy J; Burek-Huntington, Kathleen A; Ylitalo, Gina M; Fadely, Brian S; Pitcher, Kenneth W
2016-01-15
The relationships of selected organochlorine (OC) contaminants between blubber, blood, feces, and milk of young, free-ranging Steller sea lions (Eumetopias jubatus) were examined. Both between and within each tissue there was considerable individual variation. In spite of the variation, similar patterns were observed across the tissues for most of the selected PCB congeners. In all four tissues, the major PCB congeners were PCB101, PCB118, PCB138, and PCB153. The most prominent congener, both as a weight (ng/g lipid) and as a percentage of summed PCBs (∑PCBs), was PCB 153. Comparisons between paired tissues showed that ∑DDTs in blubber samples were related to concentrations in blood, feces, and milk. The ∑PCBs in blubber were related to concentrations in milk and fecal samples, though the relationship with feces was weak. Our findings show milk samples, in particular, are useful for assessing OCs in young sea lions. Blubber concentrations of PCB101, PCB118, and PCB138 were an order of magnitude higher than those in milk, supporting the biomagnification of these PCB congeners in SSL tissues. The findings indicate alternative tissues may be used as indicators of relative contaminant exposure in lieu of surgical blubber biopsy. Copyright © 2015 Elsevier B.V. All rights reserved.
NHEXAS PHASE I MARYLAND STUDY--LIPIDS IN BLOOD ANALYTICAL RESULTS
The Lipids in Blood data set presents concentrations of cholesterol and total triglycerides in blood serum. The data set presents measurements for up to 2 lipids in 358 blood samples over 79 households. Each sample was collected via a venous sample from the primary respondent w...
Djordjevic, B; Kristensen, T; Øverli, Ø; Rosseland, B O; Kiessling, A
2012-02-01
Recovery from implantation of a cannula in the dorsal aorta (DA) of Atlantic salmon (Salmo salar) was studied in relation to nutritional status and sampling intensity. The incentive for the study was the inconsistency between published reports and our own experience of recovery and longevity of fish exposed to this protocol. In two studies using starved fish, blood (0.3 ml) was sampled 0, 1 and 24 h after DA-cannulation, and thereafter at 48 and 72 h and thereafter once weekly for four weeks. In a third study using fed fish, four consecutive samples (0, 3, 6 and 12 h after a meal) were obtained twice a week over a four-week period. All fish displayed a sharp increase in pCO(2) and haematocrit (Hct) during surgery, followed by a marked raise in cortisol, glucose, sodium and potassium (1 h). pCO(2), pH and Hct approached baseline levels as early as the 1 h post-surgery sample, while this was not the case for cortisol and electrolytes before the 24 h post-surgery sample. Glucose did not display any significant changes post surgery. From then on, all variables displayed minor but non-significant (P > 0.05) changes indicating a steady state close to baseline values for unstressed fish. This pattern was independent of sampling procedure, i.e. repeated single or multiple samples and thus volume of blood removed. Nutritional status (fed vs. starved) did not affect post-surgical recovery pattern. Only K(+) and Hct displayed consistent and significant post-prandial patterns. We found marked differences between baseline level of cannulated fish and uncannulated control fish, in pH, K(+) and Hct indicating that cannulation may be the preferred method to obtain representative resting values in fish.
Cramer, Stig P; Modvig, Signe; Simonsen, Helle J; Frederiksen, Jette L; Larsson, Henrik B W
2015-09-01
Optic neuritis is an acute inflammatory condition that is highly associated with multiple sclerosis. Currently, the best predictor of future development of multiple sclerosis is the number of T2 lesions visualized by magnetic resonance imaging. Previous research has found abnormalities in the permeability of the blood-brain barrier in normal-appearing white matter of patients with multiple sclerosis and here, for the first time, we present a study on the capability of blood-brain barrier permeability in predicting conversion from optic neuritis to multiple sclerosis and a direct comparison with cerebrospinal fluid markers of inflammation, cellular trafficking and blood-brain barrier breakdown. To this end, we applied dynamic contrast-enhanced magnetic resonance imaging at 3 T to measure blood-brain barrier permeability in 39 patients with monosymptomatic optic neuritis, all referred for imaging as part of the diagnostic work-up at time of diagnosis. Eighteen healthy controls were included for comparison. Patients had magnetic resonance imaging and lumbar puncture performed within 4 weeks of onset of optic neuritis. Information on multiple sclerosis conversion was acquired from hospital records 2 years after optic neuritis onset. Logistic regression analysis showed that baseline permeability in normal-appearing white matter significantly improved prediction of multiple sclerosis conversion (according to the 2010 revised McDonald diagnostic criteria) within 2 years compared to T2 lesion count alone. There was no correlation between permeability and T2 lesion count. An increase in permeability in normal-appearing white matter of 0.1 ml/100 g/min increased the risk of multiple sclerosis 8.5 times whereas having more than nine T2 lesions increased the risk 52.6 times. Receiver operating characteristic curve analysis of permeability in normal-appearing white matter gave a cut-off of 0.13 ml/100 g/min, which predicted conversion to multiple sclerosis with a sensitivity of 88% and specificity of 72%. We found a significant correlation between permeability and the leucocyte count in cerebrospinal fluid as well as levels of CXCL10 and MMP9 in the cerebrospinal fluid. These findings suggest that blood-brain barrier permeability, as measured by magnetic resonance imaging, may provide novel pathological information as a marker of neuroinflammation related to multiple sclerosis, to some extent reflecting cellular permeability of the blood-brain barrier, whereas T2 lesion count may more reflect the length of the subclinical pre-relapse phase.See Naismith and Cross (doi:10.1093/brain/awv196) for a scientific commentary on this article. © The Author (2015). Published by Oxford University Press on behalf of the Guarantors of Brain.
Rapid isolation of blood plasma using a cascaded inertial microfluidic device
Robinson, M.; Hinsdale, T.; Coté, G.
2017-01-01
Blood, saliva, mucus, sweat, sputum, and other biological fluids are often hindered in their ability to be used in point-of-care (POC) diagnostics because their assays require some form of off-site sample pre-preparation to effectively separate biomarkers from larger components such as cells. The rapid isolation, identification, and quantification of proteins and other small molecules circulating in the blood plasma from larger interfering molecules are therefore particularly important factors for optical blood diagnostic tests, in particular, when using optical approaches that incur spectroscopic interference from hemoglobin-rich red blood cells (RBCs). In this work, a sequential spiral polydimethylsiloxane (PDMS) microfluidic device for rapid (∼1 min) on-chip blood cell separation is presented. The chip utilizes Dean-force induced migration via two 5-loop Archimedean spirals in series. The chip was characterized in its ability to filter solutions containing fluorescent beads and silver nanoparticles and further using blood solutions doped with a fluorescent protein. Through these experiments, both cellular and small molecule behaviors in the chip were assessed. The results exhibit an average RBC separation efficiency of ∼99% at a rate of 5.2 × 106 cells per second while retaining 95% of plasma components. This chip is uniquely suited for integration within a larger point-of-care diagnostic system for the testing of blood plasma, and the use of multiple filtering spirals allows for the tuning of filtering steps, making this device and the underlying technique applicable for a wide range of separation applications. PMID:28405258
Quantitation of permethylated N-glycans through multiple-reaction monitoring (MRM) LC-MS/MS.
Zhou, Shiyue; Hu, Yunli; DeSantos-Garcia, Janie L; Mechref, Yehia
2015-04-01
The important biological roles of glycans and their implications in disease development and progression have created a demand for the development of sensitive quantitative glycomics methods. Quantitation of glycans existing at low abundance is still analytically challenging. In this study, an N-linked glycans quantitation method using multiple-reaction monitoring (MRM) on a triple quadrupole instrument was developed. Optimum normalized collision energy (CE) for both sialylated and fucosylated N-glycan was determined to be 30%, whereas it was found to be 35% for either fucosylated or sialylated N-glycans. The optimum CE for mannose and complex type N-glycan was determined to be 35%. Additionally, the use of three transitions was shown to facilitate reliable quantitation. A total of 88 N-glycan compositions in human blood serum were quantified using this MRM approach. Reliable detection and quantitation of these glycans was achieved when the equivalence of 0.005 μL of blood serum was analyzed. Accordingly, N-glycans down to the 100th of a μL level can be reliably quantified in pooled human blood serum, spanning a dynamic concentration range of three orders of magnitude. MRM was also effectively utilized to quantitatively compare the expression of N-glycans derived from brain-targeting breast carcinoma cells (MDA-MB-231BR) and metastatic breast cancer cells (MDA-MB-231). Thus, the described MRM method of permethylated N-glycan enables a rapid and reliable identification and quantitation of glycans derived from glycoproteins purified or present in complex biological samples.
Quantitation of Permethylated N-Glycans through Multiple-Reaction Monitoring (MRM) LC-MS/MS
NASA Astrophysics Data System (ADS)
Zhou, Shiyue; Hu, Yunli; DeSantos-Garcia, Janie L.; Mechref, Yehia
2015-04-01
The important biological roles of glycans and their implications in disease development and progression have created a demand for the development of sensitive quantitative glycomics methods. Quantitation of glycans existing at low abundance is still analytically challenging. In this study, an N-linked glycans quantitation method using multiple-reaction monitoring (MRM) on a triple quadrupole instrument was developed. Optimum normalized collision energy (CE) for both sialylated and fucosylated N-glycan was determined to be 30%, whereas it was found to be 35% for either fucosylated or sialylated N-glycans. The optimum CE for mannose and complex type N-glycan was determined to be 35%. Additionally, the use of three transitions was shown to facilitate reliable quantitation. A total of 88 N-glycan compositions in human blood serum were quantified using this MRM approach. Reliable detection and quantitation of these glycans was achieved when the equivalence of 0.005 μL of blood serum was analyzed. Accordingly, N-glycans down to the 100th of a μL level can be reliably quantified in pooled human blood serum, spanning a dynamic concentration range of three orders of magnitude. MRM was also effectively utilized to quantitatively compare the expression of N-glycans derived from brain-targeting breast carcinoma cells (MDA-MB-231BR) and metastatic breast cancer cells (MDA-MB-231). Thus, the described MRM method of permethylated N-glycan enables a rapid and reliable identification and quantitation of glycans derived from glycoproteins purified or present in complex biological samples.
Lossius, Andreas; Johansen, Jorunn N; Vartdal, Frode; Robins, Harlan; Jūratė Šaltytė, Benth; Holmøy, Trygve; Olweus, Johanna
2014-11-01
Epstein-Barr virus (EBV) has long been suggested as a pathogen in multiple sclerosis (MS). Here, we used high-throughput sequencing to determine the diversity, compartmentalization, persistence, and EBV-reactivity of the T-cell receptor (TCR) repertoires in MS. TCR-β genes were sequenced in paired samples of cerebrospinal fluid (CSF) and blood from patients with MS and controls with other inflammatory neurological diseases. The TCR repertoires were highly diverse in both compartments and patient groups. Expanded T-cell clones, represented by TCR-β sequences >0.1%, were of different identity in CSF and blood of MS patients, and persisted for more than a year. Reference TCR-β libraries generated from peripheral blood T cells reactive against autologous EBV-transformed B cells were highly enriched for public EBV-specific sequences and were used to quantify EBV-reactive TCR-β sequences in CSF. TCR-β sequences of EBV-reactive CD8+ T cells, including several public EBV-specific sequences, were intrathecally enriched in MS patients only, whereas those of EBV-reactive CD4+ T cells were also enriched in CSF of controls. These data provide evidence for a clonally diverse, yet compartmentalized and persistent, intrathecal T-cell response in MS. The presented strategy links TCR sequence to intrathecal T-cell specificity, demonstrating enrichment of EBV-reactive CD8+ T cells in MS. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Glucose Meters: A Review of Technical Challenges to Obtaining Accurate Results
Tonyushkina, Ksenia; Nichols, James H.
2009-01-01
Glucose meters are universally utilized in the management of hypoglycemic and hyperglycemic disorders in a variety of healthcare settings. Establishing the accuracy of glucose meters, however, is challenging. Glucose meters can only analyze whole blood, and glucose is unstable in whole blood. Technical accuracy is defined as the closeness of agreement between a test result and the true value of that analyte. Truth for glucose is analysis by isotope dilution mass spectrometry, and frozen serum standards analyzed by this method are available from the National Institute of Standards and Technology. Truth for whole blood has not been established, and cells must be separated from the whole blood matrix before analysis by a method like isotope dilution mass spectrometry. Serum cannot be analyzed by glucose meters, and isotope dilution mass spectrometry is not commonly available in most hospitals and diabetes clinics to evaluate glucose meter accuracy. Consensus standards recommend comparing whole blood analysis on a glucose meter against plasma/serum centrifuged from a capillary specimen and analyzed by a clinical laboratory comparative method. Yet capillary samples may not provide sufficient volume to test by both methods, and venous samples may be used as an alternative when differences between venous and capillary blood are considered. There are thus multiple complexities involved in defining technical accuracy and no clear consensus among standards agencies and professional societies on accuracy criteria. Clinicians, however, are more concerned with clinical agreement of the glucose meter with a serum/plasma laboratory result. Acceptance criteria for clinical agreement vary across the range of glucose concentrations and depend on how the result will be used in screening or management of the patient. A variety of factors can affect glucose meter results, including operator technique, environmental exposure, and patient factors, such as medication, oxygen therapy, anemia, hypotension, and other disease states. This article reviews the challenges involved in obtaining accurate glucose meter results. PMID:20144348
Del Pozo, G; Davalos, P; Yamori, Y
1990-01-01
We examined the specific hypotheses linking the intake of sodium, potassium, calcium, magnesium, and protein to blood pressure (BP) and the relationship between dietary factors and mortality from the major cardiovascular diseases (CVD) in the Ecuadorian populations. Two Ecuadorian populations, the urban and the rural, were selected from Quito and Vilcabamba, respectively. From Quito: 87 men and 83 women; from Vilcabamba: 71 men and 91 women aged 50-54 were randomly selected for BP measurement, 24-h urine collection, and blood sampling according to the Cardiovascular Disease and Alimentary Comparison (CARDIAC) Study protocol. Samples were analyzed at CARDIAC center in Izumo, Japan. Mean systolic blood pressure (SBP) was not much different in the two populations, but mean diastolic blood pressure (DBP) and body mass index (BMI) were significantly lower in Vilcabamba (p less than 0.001). Mortality from stroke was higher in Vilcabamba, whereas coronary death rate was higher in Quito. Both sodium intake and sodium/potassium ratio were higher in Vilcabamba (p less than 0.001). Protein intake and serum cholesterol were higher in Quito (p less than 0.001). Urinary taurine excretion was higher in Quito. There was no difference in W3/W6 fatty acids ratio between the two populations. Multiple regression analyses of intracommunity correlation indicated that both SBP and DBP were highly significantly related with BMI in Quito and that urinary excretions were inversely related to SBP. Serum cholesterol was positively related to coronary death rate. Mortality from stroke was inversely related to both serum cholesterol and protein and was positively related to salt consumption.
Crayton, Samuel H; Elias, Drew R; Al Zaki, Ajlan; Cheng, Zhiliang; Tsourkas, Andrew
2012-02-01
Recent advances in material science and chemistry have led to the development of nanoparticles with diverse physicochemical properties, e.g. size, charge, shape, and surface chemistry. Evaluating which physicochemical properties are best for imaging and therapeutic studies is challenging not only because of the multitude of samples to evaluate, but also because of the large experimental variability associated with in vivo studies (e.g. differences in tumor size, injected dose, subject weight, etc.). To address this issue, we have developed a lanthanide-doped nanoparticle system and analytical method that allows for the quantitative comparison of multiple nanoparticle compositions simultaneously. Specifically, superparamagnetic iron oxide (SPIO) with a range of different sizes and charges were synthesized, each with a unique lanthanide dopant. Following the simultaneous injection of the various SPIO compositions into tumor-bearing mice, inductively coupled plasma mass spectroscopy (ICP-MS) was used to quantitatively and orthogonally assess the concentration of each SPIO composition in serial blood samples and the resected tumor and organs. The method proved generalizable to other nanoparticle platforms, including dendrimers, liposomes, and polymersomes. This approach provides a simple, cost-effective, and non-radiative method to quantitatively compare tumor localization, biodistribution, and blood clearance of more than 10 nanoparticle compositions simultaneously, removing subject-to-subject variability. Copyright © 2011 Elsevier Ltd. All rights reserved.
Matuszak, Małgorzata; Minorczyk, Maria; Góralczyk, Katarzyna; Hernik, Agnieszka; Struciński, Paweł; Liszewska, Monika; Czaja, Katarzyna; Korcz, Wojciech; Łyczewska, Monika; Ludwicki, Jan K
2016-01-01
Polybrominated diphenyl ethers (PBDEs) as other persistent organic pollutants like polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs) pose a significant hazard to human health, mainly due to interference with the endocrine system and carcinogenetic effects. Humans are exposed to these substances mainly through a food of animal origin. These pollutants are globally detected in human matrices which requires to dispose reliable and simple analytical method that would enable further studies to assess the exposure of specific human populations to these compounds. The purpose of this study was to modify and validate of the analytical procedure for the simultaneous determination of selected PBDEs, PCBs and OCPs in human blood serum samples. The analytical measurement was performed by GC-µECD following preparation of serum samples (denaturation, multiple extraction, lipid removal). Identity of the compounds was confirmed by GC-MS. The method was characterised by the appropriate linearity, good repeatability (CV below 20%). The recoveries ranged from 52.9 to 125.0% depending on compound and level of fortification. The limit of quantification was set at 0.03 ng mL(-1) of serum. The modified analytical method proved to be suitable for the simultaneous determination of selected PBDEs, PCBs and OCPs in human blood serum by GC-µECD with good precision.
Paparini, Andrea; Macgregor, James; Ryan, Una M; Irwin, Peter J
2015-12-01
Piroplasms, tick-transmitted Apicomplexa of the genera Theileria, Babesia and Cytauxzoon, are blood-borne parasites of clinical and veterinary importance. The order Piroplasmida shows a puzzling systematics characterized by multiple clades, soft polytomies and paraphyletic/polyphyletic genera. In the present study, screening of platypuses (Ornithorhynchus anatinus), was performed to infer the parasite molecular phylogeny. DNA was extracted from blood, ectoparasites and tick eggs and the 18S rRNA- hsp70-genes were used for the phylogenetic reconstructions. Microscopic analyses detected pleomorphic intra-erythrocytic organisms and tetrads consistent with previous descriptions of Theileria ornithorhynchi Mackerras, 1959, but observation of possible schizonts could not be confirmed. DNA sequences obtained from blood and ticks allowed resolving the systematics of the first piroplasm infecting a monotreme host. Molecularly, T. ornithorhynchi formed a novel monophyletic group, basal to most known piroplasms' clades. The ancestral position of this clade, isolated from an ancient lineage of mammalian host appears particularly fascinating. The present paper discusses the inadequacies of the current molecular systematics for the Piroplasmida and the consequences of incomplete sampling, morphology-based classification and ambiguous microscopic identifications. Likely when the current sampling bias is rectified and more sequence data is made available, the phylogenetic position of T. ornithorhynchi will be further contextualized without ambiguity. Copyright © 2015 Elsevier GmbH. All rights reserved.
Kalathia, Mitul Babubhai; Shingala, Prakash Ashokbhai; Parmar, Parin Niranjanbhai; Parikh, Yogesh Narenedrabhai; Kalathia, Ila Mitulkumar
2013-10-01
Blood culture is gold standard for diagnosis of neonatal sepsis. Low sensitivity of blood culture is usually due to small volume of blood sample, intrapartum antibiotics, and antibiotics given to newborn before sampling. We evaluated use of Umbilical cord blood culture (UCBC) in diagnosis of neonatal sepsis as compared to peripheral venous blood culture. This study was done in tertiary care teaching hospital during May-June 2012. A total of 45 newborns with presence of two or more risk factors of sepsis were included. Blood sample from placental end of umbilical cord was collected and cultured. Primary outcome was diagnosis of neonatal sepsis by use of umbilical cord blood sample as compared with venous blood sample. Secondary outcome was to compare organisms identified by UCBC and venous blood culture. Sensitivity, specificity, positive and negative predictive values of UCBC were calculated. A total of 24.44% (11 out of 45) high-risk newborns had positive UCBC. A total of 17.8% (8 out of 45) newborns had positive blood culture report. Organisms grown in UCBC were Pseudomonas (45%, 5 out of 11), Acinetobacter (27.27%, 3 out of 11), Escherichia coli (18.18%, 2 out of 11), and Klebsiella (9%, 1 out of 11). UCBC is a good method for diagnosis of neonatal sepsis among high-risk newborns as compared to venous blood culture with a sensitivity of 80% and specificity of 91.43%. Organisms grown are comparable to blood culture samples.
Fagge, Timothy J; Barclay, G Robin; Stove, G Colin; Stove, Gordon; Robinson, Michael J; Head, Mark W; Ironside, James W; Turner, Marc L
2007-01-01
Background Sub-clinical variant Creutzfeldt-Jakob disease (vCJD) infection and reports of vCJD transmission through blood transfusion emphasise the need for blood screening assays to ensure the safety of blood and transplanted tissues. Most assays aim to detect abnormal prion protein (PrPSc), although achieving required sensitivity is a challenge. Methods We have used innovative Atomic Dielectric Resonance Spectroscopy (ADRS), which determines dielectric properties of materials which are established by reflectivity and penetration of radio/micro waves, to analyse blood samples from patients and controls to identify characteristic ADR signatures unique to blood from vCJD and to sCJD patients. Initial sets of blood samples from vCJD, sCJD, non-CJD neurological diseases and normal healthy adults (blood donors) were screened as training samples to determine group-specific ADR characteristics, and provided a basis for classification of blinded sets of samples. Results Blood sample groups from vCJD, sCJD, non-CJD neurological diseases and normal healthy adults (blood donors) screened by ADRS were classified with 100% specificity and sensitivity, discriminating these by a co-variance expert analysis system. Conclusion ADRS appears capable of recognising and discriminating serum samples from vCJD, sCJD, non-CJD neurological diseases, and normal healthy adults, and might be developed to provide a system for primary screening or confirmatory assay complementary to other screening systems. PMID:17760958
Patient identification in blood sampling.
Davidson, Anne; Bolton-Maggs, Paula
The majority of adverse reports relating to blood transfusions result from human error, including misidentification of patients and incorrect labelling of samples. This article outlines best practice in blood sampling for transfusion (but is recommended for all pathology samples) and the role of patient empowerment in improving safety.
Sampling and storage of blood for pH and blood gas analysis.
Haskins, S C
1977-02-15
Techniques used in sampling and storage of a blood sample for pH and gas measurements can have an important effect on the measured values. Observation of these techniques and principles will minimize in vitro alteration of the pH and blood gas values. To consider that a significant change has occurred in a pH or blood gas measurement from previous values, the change must exceed 0.015 for pH, 3 mm Hg for PCO2, 5 mm Hg for PO2, and 2 mEq/L for [HCO-3] or base excess/deficit. In vitro dilution of the blood sample with anticoagulant should be avoided because it will alter the measured PCO2 and base excess/deficit values. Arterial samples should be collected for meaningful pH and blood gas values. Central venous and free-flowing capillary blood can be used for screening procedures in normal patients but are subject to considerable error. A blood sample can be stored for up to 30 minutes at room temperature without significant change in acid-base values but only up to 12 minutes before significant changes occur in PO2. A blood sample can be stored for up to 3.5 hours in an ice-water bath without significant change in pH and for 6 hours without significant change in PCO2 or PO2. Variations of body temperatures from normal will cause a measurable change in pH and blood gas values when the blood is exposed to the normal water bath temperatures of the analyzer.
Paviglianiti, Annalisa; Xavier, Erick; Ruggeri, Annalisa; Ceballos, Patrice; Deconinck, Eric; Cornelissen, Jan J; Nguyen-Quoc, Stephanie; Maillard, Natacha; Sanz, Guillermo; Rohrlich, Pierre-Simon; Garderet, Laurent; Volt, Fernanda; Rocha, Vanderson; Kroeger, Nicolaus; Gluckman, Eliane; Fegueux, Nathalie; Mohty, Mohamad
2016-09-01
Although allogeneic stem cell transplantation is not a standard therapy for multiple myeloma, some patients can benefit from this intense therapy. There are few reports on outcomes after umbilical cord blood transplantation in multiple myeloma, and investigation of this procedure is warranted. We retrospectively analyzed 95 patients, 85 with multiple myeloma and 10 with plasma cell leukemia, receiving single or double umbilical cord blood transplantation from 2001 to 2013. Median follow up was 41 months. The majority of patients received a reduced intensity conditioning. The cumulative incidence of neutrophil engraftment was 97%±3% at 60 days, and that of 100-day acute graft-versus-host disease grade II-IV was 41%±5%. Chronic graft-versus-host disease at two years was 22%±4%. Relapse and non-relapse mortality was 47%±5% and 29%±5% at three years, respectively. Three-year progression-free survival and overall survival were 24%±5% and 40%±5%, respectively. Anti-thymocyte globulin was associated with decreased incidence of acute graft-versus-host disease, higher non-relapse mortality, decreased overall and progression-free survival. Patients with high cytogenetic risk had higher relapse, and worse overall and progression-free survival. In conclusion, umbilical cord blood transplantation is feasible for multiple myeloma patients. Copyright© Ferrata Storti Foundation.
Microarray characterization of gene expression changes in blood during acute ethanol exposure
2013-01-01
Background As part of the civil aviation safety program to define the adverse effects of ethanol on flying performance, we performed a DNA microarray analysis of human whole blood samples from a five-time point study of subjects administered ethanol orally, followed by breathalyzer analysis, to monitor blood alcohol concentration (BAC) to discover significant gene expression changes in response to the ethanol exposure. Methods Subjects were administered either orange juice or orange juice with ethanol. Blood samples were taken based on BAC and total RNA was isolated from PaxGene™ blood tubes. The amplified cDNA was used in microarray and quantitative real-time polymerase chain reaction (RT-qPCR) analyses to evaluate differential gene expression. Microarray data was analyzed in a pipeline fashion to summarize and normalize and the results evaluated for relative expression across time points with multiple methods. Candidate genes showing distinctive expression patterns in response to ethanol were clustered by pattern and further analyzed for related function, pathway membership and common transcription factor binding within and across clusters. RT-qPCR was used with representative genes to confirm relative transcript levels across time to those detected in microarrays. Results Microarray analysis of samples representing 0%, 0.04%, 0.08%, return to 0.04%, and 0.02% wt/vol BAC showed that changes in gene expression could be detected across the time course. The expression changes were verified by qRT-PCR. The candidate genes of interest (GOI) identified from the microarray analysis and clustered by expression pattern across the five BAC points showed seven coordinately expressed groups. Analysis showed function-based networks, shared transcription factor binding sites and signaling pathways for members of the clusters. These include hematological functions, innate immunity and inflammation functions, metabolic functions expected of ethanol metabolism, and pancreatic and hepatic function. Five of the seven clusters showed links to the p38 MAPK pathway. Conclusions The results of this study provide a first look at changing gene expression patterns in human blood during an acute rise in blood ethanol concentration and its depletion because of metabolism and excretion, and demonstrate that it is possible to detect changes in gene expression using total RNA isolated from whole blood. The analysis approach for this study serves as a workflow to investigate the biology linked to expression changes across a time course and from these changes, to identify target genes that could serve as biomarkers linked to pilot performance. PMID:23883607
Plasma cell dyscrasia; Plasma cell myeloma; Malignant plasmacytoma; Plasmacytoma of bone; Myeloma - multiple ... Multiple myeloma most commonly causes: Low red blood cell count ( anemia ), which can lead to fatigue and ...
The care of a child with multiple trauma and severe anemia who was a Jehovah's Witness.
Digieri, Luciana Andrea; Pistelli, Ivan Pollastrini; de Carvalho, Cid Eduardo
2006-06-01
Jehovah's Witness followers do not accept blood derived transfusions and available methods for avoiding transfusion have been used with degrees of success, demonstrating that the probability of death after trauma in these patients may not be significantly different from religious groups. In this report, we describe the case of a child victim of a multiple trauma with severe anemia due to blood loss, whose family would not authorize blood transfusion because of their Jehovah's Witness faith. We discuss the current indications for restricting transfusion, as well as highlighting new tools that contribute to the success of minimizing blood loss, thus avoiding transfusion.
Method of high-precision microsampled blood and plasma mass densitometry
NASA Technical Reports Server (NTRS)
Hinghofer-Szalkay, H.
1986-01-01
The reliability of the mechanical oscillator technique for blood and plasma density measurements on samples of volumes less than 0.1 ml is examined, and a precision of 0.001 g/l is found if plasma-isodensic heparin solution and siliconized densitometers are employed. Sources of measurement errors in the density determinations include storage of plasma samples, inhomogeneity of blood samples, and density reading before adequate temperature equilibration. In tests of plasma sample storage, the best reproducibility was obtained with samples kept at 4 C. Linear correlations were found between plasma density and plasma protein concentration, blood density and blood hemoglobin concentration, and erythrocyte density and MCHC.
A technique for extracting blood samples from mice in fire toxicity tests
NASA Technical Reports Server (NTRS)
Bucci, T. J.; Hilado, C. J.; Lopez, M. T.
1976-01-01
The extraction of adequate blood samples from moribund and dead mice has been a problem because of the small quantity of blood in each animal and the short time available between the animals' death and coagulation of the blood. These difficulties are particularly critical in fire toxicity tests because removal of the test animals while observing proper safety precautions for personnel is time-consuming. Techniques for extracting blood samples from mice were evaluated, and a technique was developed to obtain up to 0.8 ml of blood from a single mouse after death. The technique involves rapid exposure and cutting of the posterior vena cava and accumulation of blood in the peritoneal space. Blood samples of 0.5 ml or more from individual mice have been consistently obtained as much as 16 minutes after apparent death. Results of carboxyhemoglobin analyses of blood appeared reproducible and consistent with carbon monoxide concentrations in the exposure chamber.
Rutten, Niels; Gonzales, José L.; Elbers, Armin R. W.; Velthuis, Annet G. J.
2012-01-01
Background As low pathogenic avian influenza viruses can mutate into high pathogenic viruses the Dutch poultry sector implemented a surveillance system for low pathogenic avian influenza (LPAI) based on blood samples. It has been suggested that egg yolk samples could be sampled instead of blood samples to survey egg layer farms. To support future decision making about AI surveillance economic criteria are important. Therefore a cost analysis is performed on systems that use either blood or eggs as sampled material. Methodology/Principal Findings The effectiveness of surveillance using egg or blood samples was evaluated using scenario tree models. Then an economic model was developed that calculates the total costs for eight surveillance systems that have equal effectiveness. The model considers costs for sampling, sample preparation, sample transport, testing, communication of test results and for the confirmation test on false positive results. The surveillance systems varied in sampled material (eggs or blood), sampling location (farm or packing station) and location of sample preparation (laboratory or packing station). It is shown that a hypothetical system in which eggs are sampled at the packing station and samples prepared in a laboratory had the lowest total costs (i.e. € 273,393) a year. Compared to this a hypothetical system in which eggs are sampled at the farm and samples prepared at a laboratory, and the currently implemented system in which blood is sampled at the farm and samples prepared at a laboratory have 6% and 39% higher costs respectively. Conclusions/Significance This study shows that surveillance for avian influenza on egg yolk samples can be done at lower costs than surveillance based on blood samples. The model can be used in future comparison of surveillance systems for different pathogens and hazards. PMID:22523543
NHEXAS PHASE I MARYLAND STUDY--PESTICIDES IN BLOOD ANALYTICAL RESULTS
The Pesticides in Blood Serum data set contains analytical results for measurements of up to 17 pesticides in 358 blood samples over 79 households. Each sample was collected via a venous sample from the primary respondent within each household by a phlebotomist. Samples were ge...
Krleza, Jasna Lenicek; Dorotic, Adrijana; Grzunov, Ana; Maradin, Miljenka
2015-01-01
Capillary blood sampling is a medical procedure aimed at assisting in patient diagnosis, management and treatment, and is increasingly used worldwide, in part because of the increasing availability of point-of-care testing. It is also frequently used to obtain small blood volumes for laboratory testing because it minimizes pain. The capillary blood sampling procedure can influence the quality of the sample as well as the accuracy of test results, highlighting the need for immediate, widespread standardization. A recent nationwide survey of policies and practices related to capillary blood sampling in medical laboratories in Croatia has shown that capillary sampling procedures are not standardized and that only a small proportion of Croatian laboratories comply with guidelines from the Clinical Laboratory Standards Institute (CLSI) or the World Health Organization (WHO). The aim of this document is to provide recommendations for capillary blood sampling. This document has been produced by the Working Group for Capillary Blood Sampling within the Croatian Society of Medical Biochemistry and Laboratory Medicine. Our recommendations are based on existing available standards and recommendations (WHO Best Practices in Phlebotomy, CLSI GP42-A6 and CLSI C46-A2), which have been modified based on local logistical, cultural, legal and regulatory requirements. We hope that these recommendations will be a useful contribution to the standardization of capillary blood sampling in Croatia. PMID:26524965
Krleza, Jasna Lenicek; Dorotic, Adrijana; Grzunov, Ana; Maradin, Miljenka
2015-01-01
Capillary blood sampling is a medical procedure aimed at assisting in patient diagnosis, management and treatment, and is increasingly used worldwide, in part because of the increasing availability of point-of-care testing. It is also frequently used to obtain small blood volumes for laboratory testing because it minimizes pain. The capillary blood sampling procedure can influence the quality of the sample as well as the accuracy of test results, highlighting the need for immediate, widespread standardization. A recent nationwide survey of policies and practices related to capillary blood sampling in medical laboratories in Croatia has shown that capillary sampling procedures are not standardized and that only a small proportion of Croatian laboratories comply with guidelines from the Clinical Laboratory Standards Institute (CLSI) or the World Health Organization (WHO). The aim of this document is to provide recommendations for capillary blood sampling. This document has been produced by the Working Group for Capillary Blood Sampling within the Croatian Society of Medical Biochemistry and Laboratory Medicine. Our recommendations are based on existing available standards and recommendations (WHO Best Practices in Phlebotomy, CLSI GP42-A6 and CLSI C46-A2), which have been modified based on local logistical, cultural, legal and regulatory requirements. We hope that these recommendations will be a useful contribution to the standardization of capillary blood sampling in Croatia.
Detection of antileishmanial antibodies in blood sampled from blood bank donors in Istanbul.
Ates, Sezen Canim; Bagirova, Malahat; Allahverdiyev, Adil M; Baydar, Serap Yesilkir; Koc, Rabia Cakir; Elcicek, Serhat; Abamor, Emrah Sefik; Oztel, Olga Nehir
2012-06-01
According to the WHO, only 5-20% of the total cases of leishmaniasis are symptomatic leishmaniasis; the other cases are identified as asymptomatic leishmaniasis. In recent studies, it has been demonstrated that donor blood plays an important role in the epidemiology of asymptomatic leishmaniasis. However, the number of the studies on this subject is still insufficient. Additionally, donor blood samples obtained from Istanbul, which is the biggest metropolitan area in Turkey, have not been investigated with regard to Leishmania. Moreover, there is no information about the sensitivity of noninvasive serological methods that are used in the detection of leishmaniasis donor blood samples. Accordingly, this study aimed to investigate the presence of antileishmanial antibodies in blood samples obtained from blood bank donors in Istanbul, by using different serologic methods, and to determine the most sensitive detection method. Blood samples were taken from 188 healthy blood bank donors to the Capa Turkish Red Crescent Blood Bank (Istanbul, Turkey), and the presence of antileishmanial antibodies was measured by indirect immunofluorescent antibody test (IFAT), ELISA, immunochromatographic dipstick rapid test, and western blot (WB). Antileishmanial antibodies were determined in 12 out of 188 samples by IFAT (6.4%), and six out of these 12 donors were found to be positive at diagnostic titer 1:128 (3.2%). One hundred and eighty eight samples were investigated by ELISA and one (0.5%) of them gave a positive result. None of 188 samples provided a positive result by immunochromatographic test. WB applied to the 12 seroreactive donors showed that three out of 12 donors were positive. In this study, the presence of antileishmanial antibodies in blood samples of blood bank donors from Istanbul has been demonstrated by using feasible and low-cost serological methods. Additionally, in comparison with other simple and low-cost detection methods, WB was used for confirmation. IFAT has a higher sensitivity and therefore may be preferred as a prescreening method in endemic or nonendemic areas.
Self-driven filter-based blood plasma separator microfluidic chip for point-of-care testing.
Madadi, Hojjat; Casals-Terré, Jasmina; Mohammadi, Mahdi
2015-05-22
There is currently a growing need for lab-on-a-chip devices for use in clinical analysis and diagnostics, especially in the area of patient care. The first step in most blood assays is plasma extraction from whole blood. This paper presents a novel, self-driven blood plasma separation microfluidic chip, which can extract more than 0.1 μl plasma from a single droplet of undiluted fresh human blood (~5 μl). This volume of blood plasma is extracted from whole blood with high purity (more than 98%) in a reasonable time frame (3 to 5 min), and without the need for any external force. This would be the first step towards the realization of a single-use, self-blood test that does not require any external force or power source to deliver and analyze a fresh whole-blood sample, in contrast to the existing time-consuming conventional blood analysis. The prototypes are manufactured in polydimethylsiloxane that has been modified with a strong nonionic surfactant (Silwet L-77) to achieve hydrophilic behavior. The main advantage of this microfluidic chip design is the clogging delay in the filtration area, which results in an increased amount of extracted plasma (0.1 μl). Moreover, the plasma can be collected in one or more 10 μm-deep channels to facilitate the detection and readout of multiple blood assays. This high volume of extracted plasma is achieved thanks to a novel design that combines maximum pumping efficiency without disturbing the red blood cells' trajectory through the use of different hydrodynamic principles, such as a constriction effect and a symmetrical filtration mode. To demonstrate the microfluidic chip's functionality, we designed and fabricated a novel hybrid microdevice that exhibits the benefits of both microfluidics and lateral flow immunochromatographic tests. The performance of the presented hybrid microdevice is validated using rapid detection of thyroid stimulating hormone within a single droplet of whole blood.
Growth hormone suppression test
GH suppression test; Glucose loading test; Acromegaly - blood test; Gigantism - blood test ... At least 3 blood samples are taken. The test is done in the following way: The first blood sample is collected between 6 ...
[Participation of leucocytes in pathogenesis of primary forms of lower limb chronic venous disease].
Bogachev, V Iu; Golovanova, O V; Sergeeva, N A; Kuznetsov, A N
2011-01-01
The purpose of the study was to test the hypothesis on participation of WBCs in damaging the venous wall in patients presenting with primary forms of lower limb chronic venous diseases LLCVD . The study included a total of fifteen consecutively selected patients (13 women and 2 men) diagnosed as having grade C2-C-4 LLCVD according to the CEAP classification. Static loading (30 minutes in the sitting position) was followed by simultaneous sampling of blood from the varicose vein of the cms and ulnar vein. The total blood count including determination of both the absolute values and percentage of blood formed elements was performed using the automated haematological counter «Advia 7» («Bayer», USA). The obtained findings were statistically processed using the Microsoft Office Excel software by means of the pared two-sample τ-test for the average values. The number of leukocytes and their subpopulations in blood samples obtained from the crural varicose veins turned out to be significantly less as compared with that in blood sampled from the ulnar vein. Thus, blood sampled from the crural varicose veins demonstrated a decrease in the counts of WBC by 9.6% in fourteen (93.3%) patients, that of neutrophils by 4.9% in twelve (80%) patients, that of lymphocytes by 16,8% in fifteen (100%) patients, and that oi monocytes by 24% in twelve (80%) patients. The mentioned differences were statistically significant at a = 0.05. The eosinophilic counts in blood sampled from the upper and lower extremities appeared similar in 66.7% of the examined subjects. In 33.3% of cases the eosinophilic count in blood samples from crural varicose vein was by 16.7% lower than that for blood samples form the ulnar vein. No differences for the rest parameters of the clinical blood count were revealed. The absolute lymphocytic count in the blood samples taken after the 30-minute static loading from the crural varicose veins was significantly lower as compared with that in blood sampled form the cubital vein. The counts for RBCs and blood platelets, as well as other qualitative haematological indices (haemoglobin, haematocrit, average volume of the RBC, erythrocytic diameter, etc.) in blood sampled form crural and ulnar veins in the same patient were identical, thus strongly suggesting the lack of either haemodynamic or haemorheological phenomena capable of leading to redistribution of the blood formed elements in varicose veins. Hence a decrease in the counts of leukocytes and their subpopulations in blood sampled from crural varicose veins might be associated with the «leukocytic trap» phenomenon.
IEP - serum; Immunoglobulin electrophoresis - blood; Gamma globulin electrophoresis; Serum immunoglobulin electrophoresis; Amyloidosis - electrophoresis serum; Multiple myeloma - serum electrophoresis; Waldenström - serum electrophoresis
Ignatova, E N; Tupoleva, T A; Ovchinnikova, E N; Romanova, T Yu; Yaroslavtseva, N G; Filatov, F P; Troitskaya, V V; Kuzmina, L A; Parovichnikova, E N; Gaponova, T V; Savchenko, V G
To evaluate the detection rate of markers for hepatitis B virus (HBV) in the blood samples taken from patients with blood system diseases, by applying the current approaches to examining donated blood and its components for markers of viral infections. The investigation included blood samples from patients with blood system diseases (n=364) and donors (n=5,011). The results of laboratory screening of donated blood samples (n=13,081) were retrospectively analyzed. Commercial kits of reagents were used for immunochemical assay and polymerase chain reaction. Patients with blood system diseases were recorded to have markers of active HBV infection in 12.6% of cases, anti-HBc in 31.3%, and anti-HBs in 37.6%. A retrospective analysis of the results of screening donated blood samples showed the presence of markers for active HBV infection in 0.28% of cases. A prospective examination of blood donors revealed markers of HBV infection in 4.83% of cases, including those of active forms in 0.54% and anti-HBc in 4.79%. The markers of active HBV infection in donors were only anti-HBc IgM in 0.42% of cases. The blood samples from donors with an anti-HBs titer of >200 mIU/ml contained anti-HBc IgM in 10.5%. In the last 5-7 years, the detection rate of markers of HBV infection in the blood samples of patients with blood system diseases have remained at a high level. Screening for decreed markers fails to identify people with inapparent infections among the donors. Even high anti-HBs concentrations in the donated blood may be a risk for HBV transmission by transfusion to a recipient.
NHEXAS PHASE I ARIZONA STUDY--METALS IN BLOOD ANALYTICAL RESULTS
The Metals in Blood data set contains analytical results for measurements of up to 2 metals in 165 blood samples over 165 households. Each sample was collected as a venous sample from the primary respondent within each household during Stage III of the NHEXAS study. The samples...
NHEXAS PHASE I MARYLAND STUDY--METALS IN BLOOD ANALYTICAL RESULTS
The Metals in Blood data set contains analytical results for measurements of up to 2 metals in 374 blood samples over 80 households. Each sample was collected via a venous sample from the primary respondent within each household by a phlebotomist. Samples were generally drawn o...
Bedside arterial blood gas monitoring system using fluorescent optical sensors
NASA Astrophysics Data System (ADS)
Bartnik, Daniel J.; Rymut, Russell A.
1995-05-01
We describe a bedside arterial blood gas (ABG) monitoring system which uses fluorescent optical sensors in the measurement of blood pH, PCO2 and PO2. The Point-of-Care Arterial Blood Gas Monitoring System consists of the SensiCathTM optical sensor unit manufactured by Optical Sensors Incorporated and the TramTM Critical Care Monitoring System with ABG Module manufactured by Marquette Electronics Incorporated. Current blood gas measurement techniques require a blood sample to be removed from the patient and transported to an electrochemical analyzer for analysis. The ABG system does not require removal of blood from the patient or transport of the sample. The sensor is added to the patient's existing arterial line. ABG measurements are made by drawing a small blood sample from the arterial line in sufficient quantity to ensure an undiluted sample at the sensor. Measurements of pH, PCO2 and PO2 are made within 60 seconds. The blood is then returned to the patient, the line flushed and results appear on the bedside monitor. The ABG system offers several advantages over traditional electrochemical analyzers. Since the arterial line remains closed during the blood sampling procedure the patient's risk of infection is reduced and the caregiver's exposure to blood is eliminated. The single-use, disposable sensor can be measure 100 blood samples over 72 hours after a single two-point calibration. Quality Assurance checks are also available and provide the caregiver the ability to assess system performance even after the sensor is patient attached. The ABG module integrates with an existing bedside monitoring system. This allows ABG results to appear on the same display as ECG, respiration, blood pressure, cardiac output, SpO2, and other clinical information. The small module takes up little space in the crowded intensive care unit. Performance studies compare the ABG system with an electrochemical blood gas analyzer. Study results demonstrated accurate and precise blood gas measurement of 100 samples and 72 hour performance without need for re-calibration.
Human blood RNA stabilization in samples collected and transported for a large biobank
2012-01-01
Background The Norwegian Mother and Child Cohort Study (MoBa) is a nation-wide population-based pregnancy cohort initiated in 1999, comprising more than 108.000 pregnancies recruited between 1999 and 2008. In this study we evaluated the feasibility of integrating RNA analyses into existing MoBa protocols. We compared two different blood RNA collection tube systems – the PAXgene™ Blood RNA system and the Tempus™ Blood RNA system - and assessed the effects of suboptimal blood volumes in collection tubes and of transportation of blood samples by standard mail. Endpoints to characterize the samples were RNA quality and yield, and the RNA transcript stability of selected genes. Findings High-quality RNA could be extracted from blood samples stabilized with both PAXgene and Tempus tubes. The RNA yields obtained from the blood samples collected in Tempus tubes were consistently higher than from PAXgene tubes. Higher RNA yields were obtained from cord blood (3 – 4 times) compared to adult blood with both types of tubes. Transportation of samples by standard mail had moderate effects on RNA quality and RNA transcript stability; the overall RNA quality of the transported samples was high. Some unexplained changes in gene expression were noted, which seemed to correlate with suboptimal blood volumes collected in the tubes. Temperature variations during transportation may also be of some importance. Conclusions Our results strongly suggest that special collection tubes are necessary for RNA stabilization and they should be used for establishing new biobanks. We also show that the 50,000 samples collected in the MoBa biobank provide RNA of high quality and in sufficient amounts to allow gene expression analyses for studying the association of disease with altered patterns of gene expression. PMID:22988904
Emeville, Elise; Giton, Frank; Giusti, Arnaud; Oliva, Alejandro; Fiet, Jean; Thomé, Jean-Pierre; Blanchet, Pascal; Multigner, Luc
2013-01-01
Background Studies relating long-term exposure to persistent organochlorine pollutants (POPs) with endocrine activities (endocrine disrupting chemicals) on circulating levels of steroid hormones have been limited to a small number of hormones and reported conflicting results. Objective We examined the relationship between serum concentrations of dehydroepiandrosterone, dehydroepiandrosterone sulphate, androstenedione, androstenediol, testosterone, free and bioavailable testosterone, dihydrotestosterone, estrone, estrone sulphate, estradiol, sex-hormone binding globulin, follicle-stimulating hormone, and luteinizing hormone as a function of level of exposure to three POPs known to interfere with hormone-regulated processes in different way: dichlorodiphenyl dichloroethene (DDE), polychlorinated biphenyl (PCB) congener 153, and chlordecone. Methods We collected fasting, morning serum samples from 277 healthy, non obese, middle-aged men from the French West Indies. Steroid hormones were determined by gas chromatography-mass spectrometry, except for dehydroepiandrosterone sulphate, which was determined by immunological assay, as were the concentrations of sex-hormone binding globulin, follicle-stimulating hormone and luteinizing hormone. Associations were assessed by multiple linear regression analysis, controlling for confounding factors, in a backward elimination procedure, in multiple bootstrap samples. Results DDE exposure was negatively associated to dihydrotestosterone level and positively associated to luteinizing hormone level. PCB 153 was positively associated to androstenedione and estrone levels. No association was found for chlordecone. Conclusions These results suggested that the endocrine response pattern, estimated by determining blood levels of steroid hormones, varies depending on the POPs studied, possibly reflecting differences in the modes of action generally attributed to these compounds. It remains to be investigated whether this response pattern is predictive of the subsequent occurrence of disease. PMID:23785499
Kretzschmar, Moritz; Schilling, Thomas; Vogt, Andreas; Rothen, Hans Ulrich; Borges, João Batista; Hachenberg, Thomas; Larsson, Anders; Baumgardner, James E; Hedenstierna, Göran
2013-10-15
The mismatching of alveolar ventilation and perfusion (VA/Q) is the major determinant of impaired gas exchange. The gold standard for measuring VA/Q distributions is based on measurements of the elimination and retention of infused inert gases. Conventional multiple inert gas elimination technique (MIGET) uses gas chromatography (GC) to measure the inert gas partial pressures, which requires tonometry of blood samples with a gas that can then be injected into the chromatograph. The method is laborious and requires meticulous care. A new technique based on micropore membrane inlet mass spectrometry (MMIMS) facilitates the handling of blood and gas samples and provides nearly real-time analysis. In this study we compared MIGET by GC and MMIMS in 10 piglets: 1) 3 with healthy lungs; 2) 4 with oleic acid injury; and 3) 3 with isolated left lower lobe ventilation. The different protocols ensured a large range of normal and abnormal VA/Q distributions. Eight inert gases (SF6, krypton, ethane, cyclopropane, desflurane, enflurane, diethyl ether, and acetone) were infused; six of these gases were measured with MMIMS, and six were measured with GC. We found close agreement of retention and excretion of the gases and the constructed VA/Q distributions between GC and MMIMS, and predicted PaO2 from both methods compared well with measured PaO2. VA/Q by GC produced more widely dispersed modes than MMIMS, explained in part by differences in the algorithms used to calculate VA/Q distributions. In conclusion, MMIMS enables faster measurement of VA/Q, is less demanding than GC, and produces comparable results.
Wiegand, Ann; Spindler, Jonathan; Hong, Feiyu F; Shao, Wei; Cyktor, Joshua C; Cillo, Anthony R; Halvas, Elias K; Coffin, John M; Mellors, John W; Kearney, Mary F
2017-05-02
Little is known about the fraction of human immunodeficiency virus type 1 (HIV-1) proviruses that express unspliced viral RNA in vivo or about the levels of HIV RNA expression within single infected cells. We developed a sensitive cell-associated HIV RNA and DNA single-genome sequencing (CARD-SGS) method to investigate fractional proviral expression of HIV RNA (1.3-kb fragment of p6, protease, and reverse transcriptase) and the levels of HIV RNA in single HIV-infected cells from blood samples obtained from individuals with viremia or individuals on long-term suppressive antiretroviral therapy (ART). Spiking experiments show that the CARD-SGS method can detect a single cell expressing HIV RNA. Applying CARD-SGS to blood mononuclear cells in six samples from four HIV-infected donors (one with viremia and not on ART and three with viremia suppressed on ART) revealed that an average of 7% of proviruses (range: 2-18%) expressed HIV RNA. Levels of expression varied from one to 62 HIV RNA molecules per cell (median of 1). CARD-SGS also revealed the frequent expression of identical HIV RNA sequences across multiple single cells and across multiple time points in donors on suppressive ART consistent with constitutive expression of HIV RNA in infected cell clones. Defective proviruses were found to express HIV RNA at levels similar to those proviruses that had no obvious defects. CARD-SGS is a useful tool to characterize fractional proviral expression in single infected cells that persist despite ART and to assess the impact of experimental interventions on proviral populations and their expression.
Mintzer, Jonathan P; Parvez, Boriana; La Gamma, Edmund F
2015-11-01
To evaluate the magnitude, consistency, and natural history of reductions in cerebral regional tissue oxygenation (CrSO2) during umbilical arterial (UA) blood sampling in very low birth weight neonates. Data were collected during a prospective observational near-infrared spectroscopy survey conducted on a convenience sample of 500-1250 g neonates during the first 10 postnatal days. A before-after analysis of UA blood sampling effects on CrSO2 absolute values and variability was performed. The present analysis was not designed a priori and was conducted following the bedside observation of CrSO2 decrements contiguous with UA blood draws. Fifteen very low birth weight neonates had 201 UA blood draws. Baseline CrSO2 (mean ± SEM) decreased following UA blood sampling, from 70 ± 1% to a nadir of 63 ± 1% (P < .001) occurring 4 ± 3 (range 2-24) minutes following blood draws. CrSO2 subsequently increased to 70 ± 1% (P < .001 compared with nadir) at 10 ± 4 (range 4-28) minutes following UA blood sampling. Coefficients of variation (mean ± SEM) increased from 0.02 ± 0.001 at baseline to 0.05 ± 0.004 (P < .001), followed by a decrease to 0.03 ± 0.003 (P < .001 for all comparisons), thus denoting increased CrSO2 variability following UA blood sampling. UA blood sampling is associated with significant CrSO2 decrements with increased variability over clinically significant intervals. Whether these changes impact complications of prematurity, including intraventricular hemorrhage and periventricular leukomalacia, remain unknown. Copyright © 2015 Elsevier Inc. All rights reserved.
Blood Culture Testing via a Mobile App That Uses a Mobile Phone Camera: A Feasibility Study
Chong, Yong Pil; Jang, Seongsoo; Kim, Mi Na; Kim, Jeong Hoon; Kim, Woo Sung
2016-01-01
Background To evaluate patients with fever of unknown origin or those with suspected bacteremia, the precision of blood culture tests is critical. An inappropriate step in the test process or error in a parameter could lead to a false-positive result, which could then affect the direction of treatment in critical conditions. Mobile health apps can be used to resolve problems with blood culture tests, and such apps can hence ensure that point-of-care guidelines are followed and processes are monitored for blood culture tests. Objective In this pilot project, we aimed to investigate the feasibility of using a mobile blood culture app to manage blood culture test quality. We implemented the app at a university hospital in South Korea to assess the potential for its utilization in a clinical environment by reviewing the usage data among a small group of users and by assessing their feedback and the data related to blood culture sampling. Methods We used an iOS-based blood culture app that uses an embedded camera to scan the patient identification and sample number bar codes. A total of 4 medical interns working at 2 medical intensive care units (MICUs) participated in this project, which spanned 3 weeks. App usage and blood culture sampling parameters (including sampler, sampling site, sampling time, and sample volume) were analyzed. The compliance of sampling parameter entry was also measured. In addition, the participants’ opinions regarding patient safety, timeliness, efficiency, and usability were recorded. Results In total, 356/644 (55.3%) of all blood culture samples obtained at the MICUs were examined using the app, including 254/356 (71.3%) with blood collection volumes of 5-7 mL and 256/356 (71.9%) with blood collection from the peripheral veins. The sampling volume differed among the participants. Sampling parameters were completely entered in 354/356 cases (99.4%). All the participants agreed that the app ensured good patient safety, disagreed on its timeliness, and did not believe that it was efficient. Although the bar code scanning speed was acceptable, the Wi-Fi environment required improvement. Moreover, the participants requested feedback regarding their sampling quality. Conclusions Although this app could be used in the clinical setting, improvements in the app functions, environment network, and internal policy of blood culture testing are needed to ensure hospital-wide use. PMID:27784649
Blood Culture Testing via a Mobile App That Uses a Mobile Phone Camera: A Feasibility Study.
Lee, Guna; Lee, Yura; Chong, Yong Pil; Jang, Seongsoo; Kim, Mi Na; Kim, Jeong Hoon; Kim, Woo Sung; Lee, Jae-Ho
2016-10-26
To evaluate patients with fever of unknown origin or those with suspected bacteremia, the precision of blood culture tests is critical. An inappropriate step in the test process or error in a parameter could lead to a false-positive result, which could then affect the direction of treatment in critical conditions. Mobile health apps can be used to resolve problems with blood culture tests, and such apps can hence ensure that point-of-care guidelines are followed and processes are monitored for blood culture tests. In this pilot project, we aimed to investigate the feasibility of using a mobile blood culture app to manage blood culture test quality. We implemented the app at a university hospital in South Korea to assess the potential for its utilization in a clinical environment by reviewing the usage data among a small group of users and by assessing their feedback and the data related to blood culture sampling. We used an iOS-based blood culture app that uses an embedded camera to scan the patient identification and sample number bar codes. A total of 4 medical interns working at 2 medical intensive care units (MICUs) participated in this project, which spanned 3 weeks. App usage and blood culture sampling parameters (including sampler, sampling site, sampling time, and sample volume) were analyzed. The compliance of sampling parameter entry was also measured. In addition, the participants' opinions regarding patient safety, timeliness, efficiency, and usability were recorded. In total, 356/644 (55.3%) of all blood culture samples obtained at the MICUs were examined using the app, including 254/356 (71.3%) with blood collection volumes of 5-7 mL and 256/356 (71.9%) with blood collection from the peripheral veins. The sampling volume differed among the participants. Sampling parameters were completely entered in 354/356 cases (99.4%). All the participants agreed that the app ensured good patient safety, disagreed on its timeliness, and did not believe that it was efficient. Although the bar code scanning speed was acceptable, the Wi-Fi environment required improvement. Moreover, the participants requested feedback regarding their sampling quality. Although this app could be used in the clinical setting, improvements in the app functions, environment network, and internal policy of blood culture testing are needed to ensure hospital-wide use.
2013-01-01
Background Genotyping requires biological sample collection that must be reliable, convenient and acceptable for patients and clinicians. Finding the most optimal procedure of sample collection for premature neonates who have a very limited blood volume is a particular challenge. The aim of the current study was to evaluate the use of umbilical cord (UC) tissue and newborn dried blood spot (DBS)-extracted genomic DNA (gDNA) as an alternative to venous blood-derived gDNA from premature neonates for molecular genetic analysis. All samples were obtained from premature newborn infants between 24-32 weeks of gestation. Paired blood and UC samples were collected from 31 study participants. gDNA was extracted from ethylenediaminetetraacetic acid (EDTA) anticoagulant-treated blood samples (~500 μl) and newborn DBSs (n = 723) using QIAamp DNA Micro kit (Qiagen Ltd., Crawley, UK); and from UC using Qiagen DNAeasy Blood and Tissue kit (Qiagen Ltd., Crawley, UK). gDNA was quantified and purity confirmed by measuring the A260:A280 ratio. PCR amplification and pyrosequencing was carried out to determine suitability of the gDNA for molecular genetic analysis. Minor allele frequency of two unrelated single nucleotide polymorphisms (SNPs) was calculated using the entire cohort. Results Both whole blood samples and UC tissue provided good quality and yield of gDNA, which was considerably less from newborn DBS. The gDNA purity was also reduced after 3 years of storage of the newborn DBS. PCR amplification of three unrelated genes resulted in clear products in all whole blood and UC samples and 86%-100% of newborn DBS. Genotyping using pyrosequencing showed 100% concordance in the paired UC and whole blood samples. Minor allele frequencies of the two SNPs indicated that no maternal gDNA contamination occurred in the genotyping of the UC samples. Conclusions gDNAs from all three sources are suitable for standard PCR and pyrosequencing assays. Given that UC provide good quality and quantity gDNA with 100% concordance in the genetic analysis with whole blood, it can replace blood sampling from premature infants. This is likely to reduce the stress and potential side effects associated with invasive sample collection and thus, greatly facilitate participant recruitment for genetic studies. PMID:24168095
Khalili, Mohammad; Eghtesadi, Shahryar; Mirshafiey, Abbas; Eskandari, Ghazaleh; Sanoobar, Meisam; Sahraian, Mohamad Ali; Motevalian, Abbas; Norouzi, Abbas; Moftakhar, Shirin; Azimi, Amirreza
2014-01-01
Multiple sclerosis is a neurodegenerative and demyelinating disease of central nervous system. High levels of oxidative stress are associated with inflammation and play an important role in pathogenesis of multiple sclerosis. This double-blind, randomized controlled clinical study was carried out to determine the effect of daily consumption of lipoic acid on oxidative stress among multiple sclerosis patients. A total of 52 relapsing-remitting multiple sclerosis patients, aged 18-50 years with Expanded Disability Status Scale ≤5.5 were assigned to consume either lipoic acid (1200 mg/day) or placebo capsules for 12 weeks. Fasting blood samples were collected before the first dose taken and 12 hours after the last. Dietary intakes were obtained by using 3-day dietary records. Consumption of lipoic acid resulted in a significant improvement of total antioxidant capacity (TAC) in comparison to the placebo group (P = 0.004). Although a significant change of TAC (-1511 mmol/L, P = 0.001) was found within lipoic acid group, other markers of oxidative stress including superoxide dismutase activity, glutathione peroxidase activity, and malondialdehyde levels were not affected by lipoic acid consumption. These results suggest that 1200 mg of lipoic acid improves serum TAC among multiple sclerosis patients but does not affect other markers of oxidative stress.
Real-time PCR detection of Plasmodium directly from whole blood and filter paper samples
2011-01-01
Background Real-time PCR is a sensitive and specific method for the analysis of Plasmodium DNA. However, prior purification of genomic DNA from blood is necessary since PCR inhibitors and quenching of fluorophores from blood prevent efficient amplification and detection of PCR products. Methods Reagents designed to specifically overcome PCR inhibition and quenching of fluorescence were evaluated for real-time PCR amplification of Plasmodium DNA directly from blood. Whole blood from clinical samples and dried blood spots collected in the field in Colombia were tested. Results Amplification and fluorescence detection by real-time PCR were optimal with 40× SYBR® Green dye and 5% blood volume in the PCR reaction. Plasmodium DNA was detected directly from both whole blood and dried blood spots from clinical samples. The sensitivity and specificity ranged from 93-100% compared with PCR performed on purified Plasmodium DNA. Conclusions The methodology described facilitates high-throughput testing of blood samples collected in the field by fluorescence-based real-time PCR. This method can be applied to a broad range of clinical studies with the advantages of immediate sample testing, lower experimental costs and time-savings. PMID:21851640
Degradation and Stabilization of Peptide Hormones in Human Blood Specimens
Yi, Jizu; Warunek, David; Craft, David
2015-01-01
Plasma hormone peptides, including GLP-1, GIP, Glucagon, and OXM, possess multiple physiological roles and potential therapeutic and diagnostic utility as biomarkers in the research of metabolic disorders. These peptides are subject to proteolytic degradation causing preanalytical variations. Stabilization for accurate quantitation of these active peptides in ex vivo blood specimens is essential for drug and biomarker development. We investigated the protease-driven instability of these peptides in conventional serum, plasma, anticoagulated whole blood, as well as whole blood and plasma stabilized with protease inhibitors. The peptide was monitored by both time-course Matrix-Assisted Laser Desorption Ionization Time-to-Flight Mass Spectrometry (MALDI –TOF MS) and Ab-based assay (ELISA or RIA). MS enabled the identification of proteolytic fragments. In non-stabilized blood samples, the results clearly indicated that dipeptidyl peptidase-IV (DPP-IV) removed the N-terminal two amino acid residues from GLP-1, GIP and OXM(1-37) and not-yet identified peptidase(s) cleave(s) the full-length OXM(1-37) and its fragments. DPP-IV also continued to remove two additional N-terminal residues of processed OXM(3–37) to yield OXM(5–37). Importantly, both DPP-IV and other peptidase(s) activities were inhibited efficiently by the protease inhibitors included in the BD P800* tube. There was preservation of GLP-1, GIP, OXM and glucagon in the P800 plasma samples with half-lives > 96, 96, 72, and 45 hours at room temperature (RT), respectively. In the BD P700* plasma samples, the stabilization of GLP-1 was also achieved with half-life > 96 hours at RT. The stabilization of these variable peptides increased their utility in drug and/or biomarker development. While stability results of GLP-1 obtained with Ab-based assay were consistent with those obtained by MS analysis, the Ab-based results of GIP, Glucagon, and OXM did not reflect the time-dependent degradations revealed by MS analysis. Therefore, we recommended characterizing the degradation of the peptide using the MS-based method when investigating the stability of a specific peptide. PMID:26222180
Relationship between plasma uridine and urinary urea excretion.
Ka, Tuneyoshi; Inokuchi, Taku; Tamada, Daisuke; Suda, Michio; Tsutsumi, Zenta; Okuda, Chihiro; Yamamoto, Asako; Takahashi, Sumio; Moriwaki, Yuji; Yamamoto, Tetsuya
2010-03-01
To investigate whether the concentration of uridine in plasma is related to the urinary excretion of urea, 45 healthy male subjects with normouricemia and normal blood pressure were studied after providing informed consent. Immediately after collection of 24-hour urine, blood samples were drawn after an overnight fast except for water. The contents of ingested foods during the 24-hour urine collection period were described by the subjects and analyzed by a dietician. Simple regression analysis showed that plasma uridine was correlated with the urinary excretions of urea (R = 0.41, P < .01), uric acid (R = 0.36, P < .05), and uridine (R = 0.30, P < .05), as well as uric acid clearance (R = 0.35, P < .05) and purine intake (R = 0.30, P < .05). In contrast, multiple regression analysis showed a positive relationship only between plasma uridine and urinary excretion of urea. These results suggest that an increase in de novo pyrimidine synthesis leads to an increased concentration of uridine in plasma via nitrogen catabolism in healthy subjects with normouricemia and normal blood pressure. (c) 2010 Elsevier Inc. All rights reserved.
Blood oxygen saturation determined by transmission spectrophotometry of hemolyzed blood samples
NASA Technical Reports Server (NTRS)
Malik, W. M.
1967-01-01
Use of the Lambert-Beer Transmission Law determines blood oxygen saturation of hemolyzed blood samples. This simplified method is based on the difference in optical absorption properties of hemoglobin and oxyhemoglobin.
Monitoring corneal crosslinking using phase-decorrelation OCT (Conference Presentation)
NASA Astrophysics Data System (ADS)
Blackburn, Brecken J.; Gu, Shi; Jenkins, Michael W.; Rollins, Andrew M.
2017-02-01
Viscosity is often a critical characteristic of biological fluids such as blood and mucus. However, traditional rheology is often inadequate when only small quantities of sample are available. A robust method to measure viscosity of microquantities of biological samples could lead to a better understanding and diagnosis of diseases. Here, we present a method to measure viscosity by observing particle Brownian motion within a sample. M-mode optical coherence tomography (OCT) imaging, obtained with a phase-sensitive 47 kHz spectral domain system, yields a viscosity measurement from multiple 200-1000 microsecond frames. This very short period of continuous acquisition, as compared to laser speckle decorrelation, decreases sensitivity to bulk motion, thereby potentially enabling in vivo and in situ applications. The theory linking g(1) first-order image autocorrelation to viscosity is derived from first principles of Brownian motion and the Stokes-Einstein relation. To improve precision, multiple windows acquired over 500 milliseconds are analyzed and the resulting linear fit parameters are averaged. Verification experiments were performed with 200 µL samples of glycerol and water with polystyrene microbeads. Lateral bulk motion up to 2 mm/s was tolerated and accurate viscosity measurements were obtained to a depth of 400 µm or more. Additionally, the method measured a significant decrease of the apparent diffusion constant of soft tissue after formalin fixation, suggesting potential for mapping tissue stiffness over a volume.
Hedrick, Valisa E; Davy, Brenda M; Wilburn, Grace A; Jahren, A Hope; Zoellner, Jamie M
2017-01-01
Objective The δ13C value of human blood is an emerging novel biomarker of added sugar (AS) intake for adults. However, no free-living, community-based assessments of comparative validity of this biomarker have been conducted. The purpose of the present investigation was to determine if Healthy Eating Index-2010 (HEI-2010) score, SoFAAS score (HEI-2010 sub-component for solid fat, alcohol and AS), AS and sugar-sweetened beverage (SSB) intakes were associated with δ13C value of fingerstick blood in a community-based sample of adults, while controlling for relevant demographics. Design A cross-sectional analysis of data obtained from assessments of BMI, dietary intake using 24 h recalls and a fingerstick blood sample was completed. Statistical analyses included descriptive statistics, multiple linear regression and one-way ANOVA. Setting Rural Southwest Virginia, USA. Subjects Adults (n 216) aged >18 years who consumed at least 837 kJ/d (200 kcal/d) from SSB. Results This sample of adult participants with low socio-economic status demonstrated a mean HEI-2010 score of 43·4 (SD 12·2), mean SoFAAS score of 10·2 (SD 5·7), mean AS intake of 93 (SD 65) g/d and mean blood δ13C value of −18·88 (SD 0·7) ‰. In four separate regression models, HEI-2010 (R2 = 0·16), SoFAAS (R2 = 0·19), AS (R2 = 0·15) and SSB (R2 = 0·14) predicted δ13C value (all P ≤0·001). Age was also predictive of δ13C value, but not sex or race. Conclusions These findings suggest that fingerstick δ13C value has the potential to be a minimally invasive method for assessing AS and SSB intake and overall dietary quality in community-based settings. Strengths, limitations and future areas of research for using an objective δ13C biomarker in diet-related public health studies are discussed. PMID:25901966
Hedrick, Valisa E; Davy, Brenda M; Wilburn, Grace A; Jahren, A Hope; Zoellner, Jamie M
2016-02-01
The δ 13C value of human blood is an emerging novel biomarker of added sugar (AS) intake for adults. However, no free-living, community-based assessments of comparative validity of this biomarker have been conducted. The purpose of the present investigation was to determine if Healthy Eating Index-2010 (HEI-2010) score, SoFAAS score (HEI-2010 sub-component for solid fat, alcohol and AS), AS and sugar-sweetened beverage (SSB) intakes were associated with δ 13C value of fingerstick blood in a community-based sample of adults, while controlling for relevant demographics. A cross-sectional analysis of data obtained from assessments of BMI, dietary intake using 24 h recalls and a fingerstick blood sample was completed. Statistical analyses included descriptive statistics, multiple linear regression and one-way ANOVA. Rural Southwest Virginia, U.S.A. Adults (n 216) aged >18 years who consumed at least 837 kJ/d (200 kcal/d) from SSB. This sample of adult participants with low socio-economic status demonstrated a mean HEI-2010 score of 43.4 (sd 12.2), mean SoFAAS score of 10.2 (sd 5.7), mean AS intake of 93 (sd 65) g/d and mean blood δ 13C value of -18.88 (sd 0.7) ‰. In four separate regression models, HEI-2010 (R 2=0.16), SoFAAS (R 2=0.19), AS (R 2=0.15) and SSB (R 2=0.14) predicted δ 13C value (all P≤0.001). Age was also predictive of δ 13C value, but not sex or race. These findings suggest that fingerstick δ 13C value has the potential to be a minimally invasive method for assessing AS and SSB intake and overall dietary quality in community-based settings. Strengths, limitations and future areas of research for using an objective δ 13C biomarker in diet-related public health studies are discussed.
Ross, Samuel Wade; Christmas, A Britton; Fischer, Peter E; Holway, Haley; Seymour, Rachel; Huntington, Ciara R; Heniford, B Todd; Sing, Ronald F
2018-06-04
The concept of hemodilution after blood loss and crystalloid infusion is a surgical maxim that remains unproven in humans. We sought to quantify the effect of hemodilution after crystalloid administration in voluntary blood donors as a model for acute hemorrhage. A prospective, randomized control trial was conducted in conjunction with community blood drives. Donors were randomized to receive no IV fluid(noIVF), two liters normal saline(NS), or two liters lactated ringers(LR) after blood donation. Blood samples were taken before donation of 500 mL of blood, immediately after donation, and following IV fluid administration. Hemoglobin(Hgb) was measured at each time point. Hgb between time points were compared between groups using standard statistical tests and the Bonferroni correction for multiple comparisons. Statistical significance was set at p≤0.0167. Of 165 patients consented, 157 patients completed the study. Average pre-donation Hgb was 14.3 g/dL. There was no difference in the mean Hgb levels after blood donation between the three groups(p>0.05). Compared to the control group, there was a significant drop in Hgb in the crystalloid infused groups from the post-donation level to post-resuscitation(13.2 vs 12.1 vs 12.2 g/dL, p<0.0001). A formula was created to predict hemoglobin levels from a given estimated blood loss(EBL) and volume replacement(VR): Hemodilution Hgb=(MeanPre-donation Hgb - hemorrhage Hgb drop - equilibration hemoglobin drop - resuscitation Hgb drop)=MeanPre-donation Hgb - [(EBL/TBV)*l] - [(EBL/TBV)*h] - [(VR/TBV)*r], l = 5.111g/dL = blood loss coefficient, h=6.722 g/dL=equilibration coefficient, r= 2.617g/dL= resuscitation coefficient. This study proves the concept of hemodilution and derived a mathematical relationship between blood loss and resuscitation. This data may help to estimate response of hemoglobin levels to blood loss and fluid resuscitation in clinical practice. Copyright © 2018. Published by Elsevier Inc.
A rapid, highly sensitive and culture-free detection of pathogens from blood by positive enrichment.
Vutukuru, Manjula Ramya; Sharma, Divya Khandige; Ragavendar, M S; Schmolke, Susanne; Huang, Yiwei; Gumbrecht, Walter; Mitra, Nivedita
2016-12-01
Molecular diagnostics is a promising alternative to culture based methods for the detection of bloodstream infections, notably due to its overall lower turnaround time when starting directly from patient samples. Whole blood is usually the starting diagnostic sample in suspected bloodstream infections. The detection of low concentrations of pathogens in blood using a molecular assay necessitates a fairly high starting volume of blood sample in the range of 5-10mL. This large volume of blood sample has a substantial accompanying human genomic content that interferes with pathogen detection. In this study, we have established a workflow using magnetic beads coated with Apolipoprotein H that makes it possible to concentrate pathogens from a 5.0mL whole blood sample, thereby enriching pathogens from whole blood background and also reducing the sample volume to ~200μL or less. We have also demonstrated that this method of enrichment allows detection of 1CFU/mL of Escherichia coli, Enterococcus gallinarum and Candida tropicalis from 5mL blood using quantitative PCR; a detection limit that is not possible in unenriched samples. The enrichment method demonstrated here took 30min to complete and can be easily integrated with various downstream molecular and microbiological techniques. Copyright © 2016 Elsevier B.V. All rights reserved.
Arterial blood gas reference values for sea level and an altitude of 1,400 meters.
Crapo, R O; Jensen, R L; Hegewald, M; Tashkin, D P
1999-11-01
Blood gas measurements were collected on healthy lifetime nonsmokers at sea level (n = 96) and at an altitude of 1,400 meters (n = 243) to establish reference equations. At each study site, arterial blood samples were analyzed in duplicate on two separate blood gas analyzers and CO-oximeters. Arterial blood gas variables included Pa(O(2)), Pa(CO(2)), pH, and calculated alveolar-arterial PO(2) difference (AaPO(2)). CO-oximeter variables were Hb, COHb, MetHb, and Sa(O(2)). Subjects were 18 to 81 yr of age with 166 male and 173 female. Outlier data were excluded from multiple regression analysis, and reference equations were fitted to the data in two ways: (1) best fit using linear, squared, and cross-product terms; (2) simple equations, including only the variables that explained at least 3% of the variance. Two sets of equations were created: (1) using only the sea level data and (2) using the combined data with barometric pressure as an independent variable. Comparisons with earlier studies revealed small but significant differences; the decline in Pa(O(2)) with age at each altitude was consistent with most previous studies. At sea level, the equation that included barometric pressure predicted Pa(O(2)) slightly better than the sea level specific equation. The inclusion of barometric pressure in the equations allows better prediction of blood gas reference values at sea level and at altitudes as high as 1,400 meters.
U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--METALS IN BLOOD ANALYTICAL RESULTS
The Metals in Blood data set contains analytical results for measurements of up to 2 metals in 86 blood samples over 86 households. Each sample was collected as a venous sample from the primary respondent within each household. The samples consisted of two 3-mL tubes. The prim...
Mercury concentrations in multiple tissues of Kittlitz's murrelets (Brachyramphus brevirostris).
Kenney, Leah A; Kaler, Robb S A; Kissling, Michelle L; Bond, Alexander L; Eagles-Smith, Collin A
2018-04-01
Mercury (Hg) is a non-essential, toxic metal that is distributed worldwide. Mercury biomagnifies in food webs and can threaten the health of top predators such as seabirds. The Kittlitz's murrelet (Brachyramphus brevirostris) is a seabird endemic to Alaska and the Russian Far East and is a species of conservation concern in the region. We determined Hg concentrations in eggshells, guano, blood, and feathers of Kittlitz's murrelets sampled from four locations in Alaska. Mercury concentrations in eggshells, guano, and blood were low compared to other seabird species. Mean Hg concentrations of breast feathers from Adak Island and Glacier Bay were significantly greater than those from Agattu Island or Icy Bay. Two Kittlitz's murrelets at Glacier Bay and one Kittlitz's murrelet at Adak Island had Hg concentrations above those associated with impaired reproduction in other bird species, and may merit further investigation as a potential threat to individuals and populations. Published by Elsevier Ltd.
Sharp, Gemma C; Arathimos, Ryan; Reese, Sarah E; Page, Christian M; Felix, Janine; Küpers, Leanne K; Rifas-Shiman, Sheryl L; Liu, Chunyu; Burrows, Kimberley; Zhao, Shanshan; Magnus, Maria C; Duijts, Liesbeth; Corpeleijn, Eva; DeMeo, Dawn L; Litonjua, Augusto; Baccarelli, Andrea; Hivert, Marie-France; Oken, Emily; Snieder, Harold; Jaddoe, Vincent; Nystad, Wenche; London, Stephanie J; Relton, Caroline L; Zuccolo, Luisa
2018-01-01
Aim: Alcohol consumption during pregnancy is sometimes associated with adverse outcomes in offspring, potentially mediated by epigenetic modifications. We aimed to investigate genome-wide DNA methylation in cord blood of newborns exposed to alcohol in utero. Materials & methods: We meta-analyzed information from six population-based birth cohorts within the Pregnancy and Childhood Epigenetics consortium. Results: We found no strong evidence of association at either individual CpGs or across larger regions of the genome. Conclusion: Our findings suggest no association between maternal alcohol consumption and offspring cord blood DNA methylation. This is in stark contrast to the multiple strong associations previous studies have found for maternal smoking, which is similarly socially patterned. However, it is possible that a combination of a larger sample size, higher doses, different timings of exposure, exploration of a different tissue and a more global assessment of genomic DNA methylation might show evidence of association. PMID:29172695
Development of Metabolic Function Biomarkers in the Common Marmoset, Callithrix jacchus
Ziegler, Toni E.; Colman, Ricki J.; Tardif, Suzette D.; Sosa, Megan E.; Wegner, Fredrick H.; Wittwer, Daniel J.; Shrestha, Hemanta
2013-01-01
Metabolic assessment of a nonhuman primate model of metabolic syndrome and obesity requires the necessary biomarkers specific to the species. While the rhesus monkey has a number of specific assays for assessing metabolic syndrome, the marmoset does not. Furthermore, the common marmoset (Callithrix jacchus) has a small blood volume that necessitates using a single blood volume for multiple analyses. The common marmoset holds a great potential as an alternative primate model for the study of human disease but assay methods need to be developed and validated for the biomarkers of metabolic syndrome. Here we report on the adaptation, development and validation of commercially available immunoassays for common marmoset samples in small volumes. We have performed biological validations for insulin, adiponectin, leptin, and ghrelin to demonstrate the use of these biomarkers in examining metabolic syndrome and other related diseases in the common marmoset. PMID:23447060
Mercury concentrations in multiple tissues of Kittlitz's murrelets (Brachyramphus brevirostris)
Kenney, Leah A.; Kaler, Robb S.; Kissling, Michelle L.; Bond, Alexander L.; Eagles-Smith, Collin A.
2018-01-01
Mercury (Hg) is a non-essential, toxic metal that is distributed worldwide. Mercury biomagnifies in food webs and can threaten the health of top predators such as seabirds. The Kittlitz's murrelet (Brachyramphus brevirostris) is a seabird endemic to Alaska and the Russian Far East and is a species of conservation concern in the region. We determined Hg concentrations in eggshells, guano, blood, and feathers of Kittlitz's murrelets sampled from four locations in Alaska. Mercury concentrations in eggshells, guano, and blood were low compared to other seabird species. Mean Hg concentrations of breast feathers from Adak Island and Glacier Bay were significantly greater than those from Agattu Island or Icy Bay. Two Kittlitz's murrelets at Glacier Bay and one Kittlitz's murrelet at Adak Island had Hg concentrations above those associated with impaired reproduction in other bird species, and may merit further investigation as a potential threat to individuals and populations.
Kamande, Joyce W; Lindell, Maria A M; Witek, Małgorzata A; Voorhees, Peter M; Soper, Steven A
2018-02-19
Blood samples from patients with plasma cell disorders were analysed for the presence of circulating plasma cells (CPCs) using a microfluidic device modified with monoclonal anti-CD138 antibodies. CPCs were immuno-phenotyped using a CD38/CD56/CD45 panel and identified in 78% of patients with monoclonal gammopathy of undetermined significance (MGUS), all patients with smouldering and symptomatic multiple myeloma (MM), and none in the controls. The burden of CPCs was higher in patients with symptomatic MM compared with MGUS and smouldering MM (p < 0.05). FISH analysis revealed the presence of chromosome 13 deletions in CPCs that correlated with bone marrow results. Point mutations in KRAS were identified, including different mutations from sub-clones derived from the same patient. The microfluidic assay represents a highly sensitive method for enumerating CPCs and allows for the cytogenetic and molecular characterization of CPCs.
Longley, Susan L; Watson, David; Noyes, Russell; Yoder, Kevin
2006-01-01
A dimensional and psychometrically informed taxonomy of anxiety is emerging, but the specific and nonspecific dimensions of panic and phobic anxiety require greater clarification. In this study, confirmatory factor analyses of data from a sample of 438 college students were used to validate a model of panic and phobic anxiety with six content factors; multiple scales from self-report measures were indicators of each model component. The model included a nonspecific component of (1) neuroticism and two specific components of panic attack, (2) physiological hyperarousal, and (3) anxiety sensitivity. The model also included three phobia components of (4) classically defined agoraphobia, (5) social phobia, and (6) blood-injection phobia. In these data, agoraphobia correlated more strongly with both the social phobia and blood phobia components than with either the physiological hyperarousal or the anxiety sensitivity components. These findings suggest that the association between panic attacks and agoraphobia warrants greater attention.
[Identification of Animal Whole Blood Based on Near Infrared Transmission Spectroscopy].
Wan, Xiong; Wang, Jian; Liu, Peng-xi; Zhang, Ting-ting
2016-01-01
The inspection and classification for blood products are important but complicated in import-export ports or inspection and quarantine departments. For the inspection of whole blood products, open sampling can cause pollution and virulence factors in bloods samples may even endanger inspectors. Thus non-contact classification and identification methods for whole bloods of animals are needed. Spectroscopic techniques adopted in the flowcytometry need sampling blood cells during the detection; therefore they can not meet the demand of non-contact identification and classification for whole bloods of animals. Infrared absorption spectroscopy is a technique that can be used to analyze the molecular structure and chemical bonds of detected samples under the condition of non-contact. To find a feasible spectroscopic approach of non-contact detection for the species variation in whole blood samples, a near infrared transmitted spectra (NITS, 4 497.669 - 7 506.4 cm(-1)) experiment of whole blood samples of three common animals including chickens, dogs and cats has been conducted. During the experiment, the spectroscopic resolution is 5 cm(-1), and each spectrogram is an average of 5 measured spectral data. Experimental results show that all samples have a sharp absorption peak between 5 184 and 5 215 cm(-1), and a gentle absorption peak near 7 000 cm(-1). Besides, the NITS curves of different samples of same animals are similar, and only have slight differences in the whole transmittance. A correlation coefficient (CC) is induced to distinguish the differences of the three animals' whole bloods in NITS curves, and the computed CCs between NITS curves of different samples of the same animals, are greater than 0.99, whereas CCs between NITS curves of the whole bloods of different animals are from 0.509 48 to 0.916 13. Among which CCs between NITS curves of the whole bloods of chickens and cats are from 0.857 23 to 0.912 44, CCs between NITS curves of the whole bloods of chickens and dogs are from 0.509 48 to 0.664 82, and CCs between NITS curves of the whole bloods of cats and dogs are from 0.872 75 to 0.916 13. The cat and the dog belong to the class of mammal, and the CCs between their whole bloods NITS curves are greater than those between chickens and cats, or chickens and dogs, which are hetero-class animals. Namely, the whole bloods NITS curves of the cat and the dog have higher similarity. These results of NITS provide a feasible method of non-contact identification of animal whole bloods.
Westenbrink, W
1992-01-01
Police officers can now demand blood samples from suspected impaired drivers in Canada to determine their Blood Alcohol Concentration. The medical laboratory technologist has been given the authority to take blood samples for legal purposes, as well as the authorization to complete certificates used as evidence in court. The proper procedures for the taking of blood samples and the completion of certificates are described in detail. The Criminal Code offences dealing with drinking and driving, the means by which police officers can legally obtain blood samples, the Blood Alcohol Kit, and the provision of providing blood collection evidence in court are discussed to aid the technologists in understanding their role in this process. The Criminal Code definitions of a "qualified medical practitioner", a "qualified technician", and "approved containers" are also described.
Congleton, J.L.; LaVoie, W.J.
2001-01-01
Thirteen blood chemistry indices were compared for samples collected by three commonly used methods: caudal transection, heart puncture, and caudal vessel puncture. Apparent biases in blood chemistry values for samples obtained by caudal transection were consistent with dilution with tissue fluids: alanine aminotransferase (ALT), aspartate aminotransferase (AST), lactate dehydrogenase (LDH), creatine kinase (CK), triglyceride, and K+ were increased and Na+ and Cl- were decreased relative to values for samples obtained by caudal vessel puncture. Some enzyme activities (ALT, AST, LDH) and K+ concentrations were also greater in samples taken by heart puncture than in samples taken by caudal vessel puncture. Of the methods tested, caudal vessel puncture had the least effect on blood chemistry values and should be preferred for blood chemistry studies on juvenile salmonids.
Metabolic predictors of middle-distance swimming performance.
Ribeiro, J P; Cadavid, E; Baena, J; Monsalvete, E; Barna, A; De Rose, E H
1990-09-01
To evaluate the capacity of different metabolic indices to predict performance in middle distance swimming, 15 competitive swimmers performed a submaximal and a maximal 400 metres freestyle swimming event. Expired gases were collected in Douglas bags immediately after the events for the determination of VO2 max. Arterialized blood samples were collected for the determination of maximal blood lactate concentration and the velocity corresponding to blood lactate concentration of 4 mM. The results demonstrated (means +/- SD): maximal velocity of 1.44 +/- 0.05 m.s-1; velocity at 85 percent of VO2 max of 1.36 +/- 0.04 m.s-1; velocity at 4 mM of 1.32 +/- 0.04 m.s-1; VO2 max of 3.47 +/- 0.5 l.min-1; maximal blood lactate concentration of 11.8 +/- 2.5 mM. Multiple regression analysis relating metabolic indices and maximal velocity demonstrated that only velocity at 85 percent of VO2 max (r2 = 0.81) and velocity at 4 mM (r2 = 0.79) were significant predictors. Thus, 79 percent of the variance in the performance of 400 m freestyle can be accounted for the velocity at 85 percent of VO2 max or the velocity at 4 mM. The success in this event seems to depend on the swimmer's capacity to achieve higher velocities with lower blood lactate levels and/or utilizing a lower percentage of their VO2 max.
Goto, Eita
2018-05-03
Caution is required for women at increased risk of low neonatal delivery weight. To evaluate relationships between maternal placentation biomarkers and the odds of low delivery weight. Databases including PubMed/MEDLINE were searched up to May 2017 using keywords involving biomarker names and "low birthweight." English language studies providing true- and false-positive, and true- and false-negative results of low delivery weight classified by maternal blood levels of placentation biomarkers (in units of multiple of the mean [MoM]) were included. Coefficients representing changes in log odds ratio for low delivery weight per 1 MoM increase in maternal blood placentation biomarkers, and those adjusted for race, sampling period, and/or study quality were calculated. Adjusted coefficients representing changes in log odds ratio for low delivery weight per 1 MoM increase in maternal blood levels of α-fetoprotein (AFP) and β-human chorionic gonadotropin (β-hCG) were significantly greater than 0 (both P<0.001), whereas that for pregnancy-associated plasma protein A (PAPP-A) was significantly less than 0 (P=0.028). Adjusted models explained the higher proportion of between-study variance better than non-adjusted models. Elevated AFP and β-hCG, and reduced PAPP-A in maternal blood were positively associated with odds of low delivery weight. © 2018 International Federation of Gynecology and Obstetrics.
Longitudinal peripheral blood transcriptional analysis of a patient with severe Ebola virus disease.
Kash, John C; Walters, Kathie-Anne; Kindrachuk, Jason; Baxter, David; Scherler, Kelsey; Janosko, Krisztina B; Adams, Rick D; Herbert, Andrew S; James, Rebekah M; Stonier, Spencer W; Memoli, Matthew J; Dye, John M; Davey, Richard T; Chertow, Daniel S; Taubenberger, Jeffery K
2017-04-12
The 2013-2015 outbreak of Ebola virus disease in Guinea, Liberia, and Sierra Leone was unprecedented in the number of documented cases, but there have been few published reports on immune responses in clinical cases and their relationships with the course of illness and severity of Ebola virus disease. Symptoms of Ebola virus disease can include severe headache, myalgia, asthenia, fever, fatigue, diarrhea, vomiting, abdominal pain, and hemorrhage. Although experimental treatments are in development, there are no current U.S. Food and Drug Administration-approved vaccines or therapies. We report a detailed study of host gene expression as measured by microarray in daily peripheral blood samples collected from a patient with severe Ebola virus disease. This individual was provided with supportive care without experimental therapies at the National Institutes of Health Clinical Center from before onset of critical illness to recovery. Pearson analysis of daily gene expression signatures revealed marked gene expression changes in peripheral blood leukocytes that correlated with changes in serum and peripheral blood leukocytes, viral load, antibody responses, coagulopathy, multiple organ dysfunction, and then recovery. This study revealed marked shifts in immune and antiviral responses that preceded changes in medical condition, indicating that clearance of replicating Ebola virus from peripheral blood leukocytes is likely important for systemic viral clearance. Copyright © 2017, American Association for the Advancement of Science.